WorldWideScience

Sample records for corrosion par piqures

  1. Piqures massives par un essaim d�abeilles chez un enfant

    Directory of Open Access Journals (Sweden)

    Mohamed Adnane Berdai

    2011-10-01

    Full Text Available Les piqures multiples d�abeilles sont responsables d�envenimation severe. Nous rapportons un cas d�une attaque massive par un essaim d�abeilles chez un enfant de sept ans. Sa gravite est liee a la localisation cephalique et au nombre important des piqures qui etait d�environ 270. Ses complications etaient l�insuffisance renale, l�anemie et une conjonctivite. La prise en charge etait symptomatique avec bonne evolution clinique et biologique.

  2. Prise en charge des intoxications par envenimation chez les enfants ...

    African Journals Online (AJOL)

    Les signes cliniques étaient dominés par les douleurs (98%) suivies des hémorragies (73,80%) pour les morsures de serpent, la douleur pour les piqures de scorpion (100%) et les oedèmes pour les piqures d'abeilles (100%). Les cas de morsure de serpent ont été traités par le sérum antivenimeux polyvalent. Conclusion: ...

  3. Piqures massives par un essaim d'abeilles chez un enfant | Berdai ...

    African Journals Online (AJOL)

    environ 270. Ses complications étaient l'insuffisance rénale, l'anémie et une conjonctivite. La prise en charge était symptomatique avec bonne évolution clinique et biologique. Key words: Abeille, envenimation, anaphylaxie, allergie, choc, Maroc ...

  4. Corrosion of metallic materials by uranium hexafluoride at high temperatures (1963); Corrosion de materiaux metalliques par l'hexafluorure d'uranium a haute temperature (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Langlois, G. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-07-01

    The corrosion of the following metals or alloys by UF{sub 6}: nickel, monel, Inconel, gold, platinum, stainless steel, is studied in the temperature range from 300 to 1000 deg. C. The test method, designed to avoid heating the apparatus containing the corrosive fluid to a high temperature, consists in using threadlike samples heated by the Joule effect, the rest of the apparatus being maintained close to room temperature. This technique makes it possible also to determine continuously the penetration of the corrosion by measuring the electrical resistance of the sample with a double Thomson bridge. A series of rapid comparison tests shows that stainless steel, precious metals and Inconel are attacked far too rapidly to be used above 500 deg. C; only monel and especially nickel appear capable of resisting at high temperatures. The detailed examination of the behaviour of nickel shows that the metallic fluoride is volatilized and that this influences the corrosion rate. It shows also the existence of a temperature zone situated between 550 and 700 deg. C in which occurs A strong intergranular corrosion the cause of which appears to be the presence of impurities in the metal. (author) [French] La corrosion par l'UF{sub 6} des metaux ou alliages suivants: lickel, monel, inconel, or, platine, acier inoxydable, est etudiee dans le un domaine de temperature compris entre 300 et 1000 deg. C. La methode d'essai, destinee a eviter le chauffage de l'enceinte contenant le fluide corrosif a temperature elevee, consiste a utiliser des eprouvettes filiformes, echauffees par effet Joule, le reste de l'appareillage etant maintenu a une temperature proche de l'ambiance. Cette technique permet en outre de determiner en continu la penetration de la corrosion, par mesure de la resistance electrique de l'eprouvette, au moyen d'un pont double de Thomson. Une serie d'essais comparatifs, assez sommaires, montre que l'acier inoxydable, les metaux

  5. Corrosion

    Science.gov (United States)

    Slabaugh, W. H.

    1974-01-01

    Presents some materials for use in demonstration and experimentation of corrosion processes, including corrosion stimulation and inhibition. Indicates that basic concepts of electrochemistry, crystal structure, and kinetics can be extended to practical chemistry through corrosion explanation. (CC)

  6. Tests on dynamic corrosion by water. Influence of the passage of a heat flux on the corrosion kinetics. pH measurement in water at high temperature; Essais de corrosion dynamique par l'eau. Influence du passage d'un flux thermique sur la cinetique de corrosion. Mesure du pH dans l'eau a haute temperature

    Energy Technology Data Exchange (ETDEWEB)

    Coriou, H.; Grall, L.; Hure, J.; Saint-James, R. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires; Berthod [Societe Grenobloise d' Etudes et d' Applications Hydrauliques, 38 (France); Le peintre [Centre National de la Recherche Scientifique (CNRS), 38 - Grenoble (France)

    1958-07-01

    The passage of a heat flux through the surface of a metal placed in a corrosive medium influences the rate of corrosion, these being higher than under adiabatic conditions. The apparatus developed for corrosion tests is described, it is possible to obtain with this equipment: 1) Heat fluxes greater than 200 W/cm{sup 2}, across aluminium canning, which is cooled by water (temperature 50 deg. C), circulating with flow rates of the order of 5 to 6 m/s. 2) Heat fluxes which can go up to 150 W/cm{sup 2}, across canning of zircaloy or stainless steel. The cooling fluid is pressurized water at a temperature around 280 deg. C, the flow-rate of circulation reaching 6 m/s. The results obtained on aluminium canning are studied from the viewpoint of corrosion, paying particular attention to cavitation phenomena which can cause serious damage in certain special circumstances. After developing a glass electrode system capable of supporting high pressures, the authors have investigated materials capable of functioning as a hydrogen electrode and of resisting satisfactorily corrosion by water at 200 deg. C. Various possibilities have been examined: electrodes of special glasses, quartz, metals, with a membrane etc... The results of the various tests and the practical limits of utilisation are given. (author)Fren. [French] Le passage d'un flux thermique a travers la surface d'un metal place dans un milieu corrosif influence les vitesses de corrosion, celles-ci etant plus elevees que dans des conditions adiabatiques. On decrit les appareils mis au point, pour essais de corrosion. Ils permettent d'obtenir: 1) A travers des gaine aluminium des flux thermiques depassant 200 W /cm{sup 2}. Les gaines sont refroidies par l'eau (temperature 50 deg. C), circulant a des vitesses de l'ordre de 5 a 6 m/s. 2) A travers des gaines en zircaloy ou acier inoxydable des flux thermiques pouvant s'elever a 150 W/cm{sup 2}. Le fluide de refroidissement est de l

  7. Allowing for surface preparation in stress corrosion cracking modelling; Prise en compte de l`etat de surface dans la modelisation de la fissuration par corrosion sous contrainte

    Energy Technology Data Exchange (ETDEWEB)

    Berge, P.; Buisine, D. [Electricite de France (EDF), 92 - Clamart (France); Gelpi, A. [FRAMATOME, 92 - Paris-La-Defence (France)

    1997-12-31

    When a 600 alloy component is significantly deformed during installation, by welding, rolling, bending, its stress corrosion cracking in Pressurized Water Nuclear Reactor`s primary coolant, is significantly changed by the initial surface treatment. Therefore, the crack initiated time may be reduced by several orders of magnitude for certain surfaces preparations. Allowing for cold working of the surface, for which modelling is proposed, depends less on the degree of cold work then on the depths of the hardened layers. Honing hardens the metal over depths of about one micron for vessel head penetrations, for example, and has little influence on subsequent behaviour after the part deforms. On the other hand, coarser turning treatment produces cold worked layers which can reach several tens of microns and can very significantly reduce the initiation time compared to fine honing. So evaluation after depths of hardening is vital on test pieces for interpreting laboratory results as well as on service components for estimating their service life. Suppression by mechanical or chemical treatment of these layers, after deformation, seems to be the most appropriate solution for reducing over-stressing connected with surface treatment carried out before deformation. (author). 14 refs.

  8. Development of hydrogen oxidizing bacteria using hydrogen from radiolysis or metal corrosion; Developpement de populations microbiennes oxydant l'hydrogene produit par radiolyse ou par corrosion des metaux

    Energy Technology Data Exchange (ETDEWEB)

    Libert, M.F.; Sellier, R.; Marty, V.; Camaro, S. [CEA Cadarache, Dept. d' Entreposage et de Stockage des Dechets (DCC/DESD/SEP), 13 - Saint-Paul-lez-Durance (France)

    2000-07-01

    The effect of many parameters need to be studied to characterize the long term behavior of nuclear waste in a deep repository. These parameters concern the chemical effects, radiolytic effects, mechanical properties, water composition, and microbiological activity. To evaluate microbial activity in such an environment, work was focused on an inventory of key nutrients (C, H, 0, N, P, S) and energy sources required for bacterial growth. The production of hydrogen in the nuclear waste environment leads to the growth of hydrogen oxidizing bacteria, which modify the gas production balance. A deep repository containing bituminized waste drums implies several sources of hydrogen: - water radiolysis; -corrosion of metal containers; - radiolysis of the embedding matrix (bitumen). Two deep geological disposal conditions leading to H{sub 2} production in a bituminized nuclear waste environment were simulated in the present study: - H{sub 2} production by iron corrosion under anaerobic conditions was simulated by adding 10% of H{sub 2} in the atmosphere; - H{sub 2} production by radiolysis of bitumen matrix was approached by subjecting this material to external gamma irradiation with a dose rate near real conditions (6 Gy/h). The presence of dissolved H{sub 2} in water allows the growth of hydrogen oxidizing bacteria leading to: - CO{sub 2} and N{sub 2} production; - H{sub 2} consumption; - lower NO{sub 3}{sup -} concentration caused by reduction to nitrogen. In the first case, hydrogen consumption is limited by the NO{sub 3}{sup -} release rate from the bitumen matrix. In the second case, however, under gamma radiation at a low dose rate, hydrogen production is weak, and the hydrogen is completely consumed by microorganisms. Knowledge about these hydrogen oxidizing bacteria is just beginning to emerge. Heterotrophic denitrifying bacteria adapt well to hydrogen metabolism (autotrophic metabolism) by oxidizing H{sub 2} instead of hydrocarbons. (authors)

  9. Caractérisation et compréhension du comportement en corrosion de structures en alliage d'aluminium-cuivre-lithium 2050 assemblées par Friction Stir Welding (FSW)

    OpenAIRE

    Proton, Vincent

    2012-01-01

    A l'heure où les matériaux composites prennent une part toujours plus importante dans les structures aéronautiques, l'utilisation de l'alliage d'aluminium-lithium 2050 assemblé par Friction Stir Welding (FSW) est envisagé pour remplacer les structures rivetées en alliages d'aluminium traditionnels. L'objectif global de ce travail de thèse était d'étudier le comportement en corrosion et en corrosion sous contrainte de joints soudés FSW de l'alliage d'aluminium-lithium 2050 mais aussi l'influen...

  10. Localized corrosion of carbon steels due to sulfate-reducing bacteria. Development of a specific sensor; Corrosion localisee des aciers au carbone induite par des bacteries sulfato-reductrices. Developpement d'un capteur specifique

    Energy Technology Data Exchange (ETDEWEB)

    Monfort Moros, N.

    2001-11-01

    This work concerns the microbiologically influenced corrosion of carbon steels in saline anaerobic media (3% of NaCl) containing sulfato-reducing bacteria (Desulfovibrio gabonensis, DSM 10636). In these media, extreme localised corrosion occurs by pitting under the bio-film covering the metallic substrate. A sensor with concentric electrodes was designed to initiate the phenomenon of bio-corrosion, recreating the favourable conditions for growth of a corrosion pit, and then measuring the corrosion current maintained by bacterial activity. The pit initiation was achieved through either of two methods. The electrochemical conditioning involved driving the potential difference between inner and outer electrodes to values corresponding to a galvanic corrosion that can be maintained by the bacterial metabolism. The mechanical process involved removal of a portion of the bio-film by scratching, yielding galvanic potential differences equivalent to that found by the conditioning technique. This protocol was found to be applicable to a bio-corrosion study on industrial site for the monitoring of the metallic structures deterioration (patent EN 00/06114, May 2000). Thereafter, a fundamental application uses the bio-corrosion sensor for Electrochemical Impedance Spectroscopy (EIS), Electrochemical Noise Analysis (ENA) and current density cartography by the means of micro-electrodes. Thus, the EIS technique reveals the importance of the FeS corrosion products for initiation of bio-corrosion start on carbon steel. In addition, depending on the method used to create a pit, the ENA gives rise to supplementary processes (gaseous release) disturbing the bio-corrosion detection. The beginning of a bio-corrosion process on a clean surface surrounded with bio-film was confirmed by the current density cartography. These different results establish the sensor with concentric electrodes as an indispensable tool for bio-corrosion studies, both in the laboratory and on industrial sites

  11. Aqueous corrosion of borosilicate glasses: experiments, modeling and Monte-Carlo simulations; Alteration par l'eau des verres borosilicates: experiences, modelisation et simulations Monte-Carlo

    Energy Technology Data Exchange (ETDEWEB)

    Ledieu, A

    2004-10-01

    This work is concerned with the corrosion of borosilicate glasses with variable oxide contents. The originality of this study is the complementary use of experiments and numerical simulations. This study is expected to contribute to a better understanding of the corrosion of nuclear waste confinement glasses. First, the corrosion of glasses containing only silicon, boron and sodium oxides has been studied. The kinetics of leaching show that the rate of leaching and the final degree of corrosion sharply depend on the boron content through a percolation mechanism. For some glass contents and some conditions of leaching, the layer which appears at the glass surface stops the release of soluble species (boron and sodium). This altered layer (also called the gel layer) has been characterized with nuclear magnetic resonance (NMR) and small angle X-ray scattering (SAXS) techniques. Second, additional elements have been included in the glass composition. It appears that calcium, zirconium or aluminum oxides strongly modify the final degree of corrosion so that the percolation properties of the boron sub-network is no more a sufficient explanation to account for the behavior of these glasses. Meanwhile, we have developed a theoretical model, based on the dissolution and the reprecipitation of the silicon. Kinetic Monte Carlo simulations have been used in order to test several concepts such as the boron percolation, the local reactivity of weakly soluble elements and the restructuring of the gel layer. This model has been fully validated by comparison with the results on the three oxide glasses. Then, it has been used as a comprehensive tool to investigate the paradoxical behavior of the aluminum and zirconium glasses: although these elements slow down the corrosion kinetics, they lead to a deeper final degree of corrosion. The main contribution of this work is that the final degree of corrosion of borosilicate glasses results from the competition of two opposite mechanisms

  12. Etude par spectroscopies d'impédance électrochimique globale et locale d'une monocouche hybride organique-inorganique respectueuse de l'environnement pour la protection contre la corrosion de l'alliage d'aluminium 2024

    OpenAIRE

    Amand, Sylvain

    2012-01-01

    L'utilisation de revêtements sol-gel pour la protection contre la corrosion des métaux est une alternative aux traitements à base de chromates, proscrits du fait de leur forte toxicité. Ces travaux de thèse ont porté sur la caractérisation de revêtements sol-gel hybrides organique-inorganique contenant des pigments inhibiteurs de corrosion non toxiques, pour la protection contre la corrosion de l'alliage d'aluminium 2024. Tout d'abord, la caractérisation par spectroscopie d'impédance électroc...

  13. In situ study by atomic force microscopy of localised corrosion on a 304L stainless steel; Etude in situ par microscopie a force atomique de la corrosion localisee d'un acier inoxydable 304L

    Energy Technology Data Exchange (ETDEWEB)

    Martin, F

    2005-12-15

    At this time, the understanding of the initiation of localized corrosion on stainless steels (SS) is still limited. In this context, the present work aimed at observing in situ by Atomic Force Microscopy (AFM) the initiation of corrosion pits and stress corrosion cracking (SCC) cracks. In order to complete the project, a new technique associating an AFM, an electrochemical cell and a traction platform as been developed. It allows in situ imaging of the surface evolutions of a 304L SS at the nano-scale. under controlled potential and/or under stress conditions. We show that corrosion pits initiate preferentially in relation with nano-metric defects of the surface. For the first time, a real-time kinetic study of the first steps of nano-metric pits growth has been performed. This study corroborates the 'point-defect' model (vertical pit growth speed of 0.18 angstrom.s{sup -1}, current densities inside pits evaluated to 73 {mu}jA.cm{sup -2}. Combined with the EBSD technique (Electron Backscattered Diffraction), the AFM allows a total indexing of the activated slip systems during deformation and give information about the number of emerged dislocations (few units). The effect of strain hardening at the nano-scale on pitting susceptibility has been investigated: 70% of the pits set up at strain hardened areas. To explain this phenomenon, we propose a simple model based on the modification of the local work function of the surface due to local stress gradients. Concerning SCC, the first in situ observations seem to validate Magnin's mechanism: crack initiation appears at strain concentration spots. Observed after anodization of our 304L surface, organized arrays of nano-cavities (period of 50-100 nm) have been analyzed. In collaboration with an INSERM team, we showed that such nano-structured surfaces increase the adhesion and differentiation of bone cells. (author)

  14. Comportement à la corrosion galvanique de matériaux composites à matrice d'alliage d'aluminium renforcée par des fibres de carbone haut-module

    OpenAIRE

    Payan, Sandrine

    2001-01-01

    The service behaviour analysis of aluminium matrix composite material reinforced with carbon fibre involves evaluating the corrosion evaluation in a saline environment. The galvanic coupling between the carbon fibres and the aluminium alloy matrix plays a main part in the degradation of these composite materials. A local analysis by an in-situ experimental approach and a semi-analytical modelling are proposed to study the corrosion initiation and propagation at the fibre/matrix interfaces. Th...

  15. Corrosion protection

    Science.gov (United States)

    Brown, Donald W.; Wagh, Arun S.

    2003-05-27

    There has been invented a chemically bonded phosphate corrosion protection material and process for application of the corrosion protection material for corrosion prevention. A slurry of iron oxide and phosphoric acid is used to contact a warm surface of iron, steel or other metal to be treated. In the presence of ferrous ions from the iron, steel or other metal, the slurry reacts to form iron phosphates which form grains chemically bonded onto the surface of the steel.

  16. Corrosion inhibition..

    African Journals Online (AJOL)

    ABSTRACT. The corrosion inhibition of carbon steel in 3% de-aerated NaCl acidic solution with amine—fatty acid corrosion inhibitor, KI384, .... reduction reaction causing no decrease in the limiting current density of that process. On the .... value when compared to the base solution. This provides a support to the physical ...

  17. Corrosion Engineering.

    Science.gov (United States)

    White, Charles V.

    A description is provided for a Corrosion and Corrosion Control course offered in the Continuing Engineering Education Program at the General Motors Institute (GMI). GMI is a small cooperative engineering school of approximately 2,000 students who alternate between six-week periods of academic study and six weeks of related work experience in…

  18. Corrosion sensor

    Science.gov (United States)

    Glass, Robert S.; Clarke, Jr., Willis L.; Ciarlo, Dino R.

    1994-01-01

    A corrosion sensor array incorporating individual elements for measuring various elements and ions, such as chloride, sulfide, copper, hydrogen (pH), etc. and elements for evaluating the instantaneous corrosion properties of structural materials. The exact combination and number of elements measured or monitored would depend upon the environmental conditions and materials used which are subject to corrosive effects. Such a corrosion monitoring system embedded in or mounted on a structure exposed to the environment would serve as an early warning system for the onset of severe corrosion problems for the structure, thus providing a safety factor as well as economic factors. The sensor array is accessed to an electronics/computational system, which provides a means for data collection and analysis.

  19. Role of hydrogen in the intergranular cracking mechanism by stress corrosion in primary medium of nickel based alloys 600 and 690; Role de l'hydrogene dans le mecanisme de fissuration intergranulaire par corrosion sous contrainte en milieu primaire des alliages base nickel 600, 690

    Energy Technology Data Exchange (ETDEWEB)

    Odemer, G.; Coudurier, A.; Jambon, F.; Chene, J. [CEA Saclay, Dept. de Physico-Chimie (DEN/DANS/DPC/SCCME/LECA), 91 - Gif sur Yvette (France); Odemer, G.; Coudurier, A.; Chene, J. [Evry Univ., UMR 8587 CNRS / CEA, LAMBE, 91 (France)

    2007-07-01

    The aim of this work is to characterize the sensitivity to hydrogen embrittlement of alloys 600 and 690 in order to better understand the eventual role of hydrogen in the stress corrosion mechanism which affects these alloys when they are exposed in PWR primary medium. (O.M.)

  20. TEM characterisation of stress corrosion cracks in nickel based alloys: effect of chromium content and chemistry of environment; Caracterisation par MET de fissures de corrosion sous contrainte d'alliages a base de nickel: influence de la teneur en chrome et de la chimie du milieu

    Energy Technology Data Exchange (ETDEWEB)

    Delabrouille, F

    2004-11-15

    Stress corrosion cracking (SCC) is a damaging mode of alloys used in pressurized water reactors, particularly of nickel based alloys constituting the vapour generator tubes. Cracks appear on both primary and secondary sides of the tubes, and more frequently in locations where the environment is not well defined. SCC sensitivity of nickel based alloys depends of their chromium content, which lead to the replacement of alloy 600 (15 % Cr) by alloy 690 (30 % Cr) but this phenomenon is not yet very well understood. The goal of this thesis is two fold: i) observe the effect of chromium content on corrosion and ii) characterize the effect of environment on the damaging process of GV tubes. For this purpose, one industrial tube and several synthetic alloys - with controlled chromium content - have been studied. Various characterisation techniques were used to study the corrosion products on the surface and within the SCC cracks: SIMS; TEM - FEG: thin foil preparation, HAADF, EELS, EDX. The effect of chromium content and surface preparation on the generalised corrosion was evidenced for synthetic alloys. Moreover, we observed the penetration of oxygen along triple junctions of grain boundaries few micrometers under the free surface. SCC tests show the positive effect of chromium for contents varying from 5 to 30 % wt. Plastic deformation induces a modification of the structure, and thus of the protective character, of the internal chromium rich oxide layer. SCC cracks which developed in different chemical environments were characterised by TEM. The oxides which are formed within the cracks are different from what is observed on the free surface, which reveals a modification of medium and electrochemical conditions in the crack. Finally we were able to evidence some structural characteristics of the corrosion products (in the cracks and on the surface) which turn to be a signature of the chemical environment. (author)

  1. Underground pipeline corrosion

    CERN Document Server

    Orazem, Mark

    2014-01-01

    Underground pipelines transporting liquid petroleum products and natural gas are critical components of civil infrastructure, making corrosion prevention an essential part of asset-protection strategy. Underground Pipeline Corrosion provides a basic understanding of the problems associated with corrosion detection and mitigation, and of the state of the art in corrosion prevention. The topics covered in part one include: basic principles for corrosion in underground pipelines, AC-induced corrosion of underground pipelines, significance of corrosion in onshore oil and gas pipelines, n

  2. Part of the hydrogen in the intergranular crack by stress corrosion in primary circuit for the 600 and 690 nickel base alloys; Role de l'hydrogene dans le mecanisme de fissuration intergranulaire par corrosion sous contrainte en milieu primaire des alliages base nickel 600 et 690

    Energy Technology Data Exchange (ETDEWEB)

    Odemer, G.; Coudurier, A.; Jambon, F.; Chene, J. [CEA Saclay, Dept. de Physico-Chimie (DPC/SCCME/LECA), 91 - Gif sur Yvette (France); Odemer, G.; Coudurier, A.; Chene, J. [Evry Univ., UMR 8587 CNRS / CEA, LAMBE, 91 (France)

    2007-07-01

    The aim of this study is, in a first part, to characterize the hydrogen embrittlement sensitivity of the 600 and 690 based alloys in order to better understand the hydrogen role in the stress corrosion mechanism which appears in theses alloys in the primary circuit of the PWR type reactors. The authors studies how the hydrogen embrittlement is resulting from an interaction between the hydrogen and the plastic deformation. (A.L.B.)

  3. Aircraft Corrosion

    Science.gov (United States)

    1981-08-01

    au traitement. micaniqus qui provoque une compression de surface - h1l’spplication i1’une double protection comportant oxydation snodique et...primaire anti-corrosion nitrosynthdtique pigmontie au chromate do zinc - une couche do peinture de finition nitrosynthdtique risistant aux huiles ...condition: - Touch-up of concerned fastener holes with chemical oxydation ; - Wet assembly of fasteners; - Application of a strontium chromate primer and

  4. Corrosion Testing Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Corrosion Testing Facility is part of the Army Corrosion Office (ACO). It is a fully functional atmospheric exposure site, called the Corrosion Instrumented Test...

  5. Iodine induced stress corrosion of zirconium and zircaloy-4 mechanisms. Translation to pellet cladding interaction conditions in PWR type reactors; Mecanismes de corrosion sous contrainte par l`iode dans le zirconium et le zircaloy-4. Transposition aux conditions d`interaction pastille-gaine dans les reacteurs a eau pressurisee

    Energy Technology Data Exchange (ETDEWEB)

    Fregonese, M

    1997-10-08

    This thesis is linked to the study of the Pellet-Cladding Interaction (PCI) phenomenon in Pressurized Water Reactors, which can lead to cladding rupture by iodine Stress Corrosion Cracking (SCC) of Zircaloy-4. Results are obtained through slow tensile tests performed in iodine methanol and in iodine vapour, on reference material, neutron irradiated material, and iodine zirconium implanted material. They allow to propose an explanation of the rapidity of the ruptures observed during PCI loadings, and to make the link between laboratory SCC tests and power ramp tests. Indeed, neutron irradiation facilitates the initiation and the transgranular propagation steps of the SCC cracks, due to strain localization and hardening associated to the presence of irradiation defects. On the other hand, recoiled iodine does not seem to affect SCC susceptibility of the material. On a chemical point of view, thermally released iodine is then responsible for PCI/SCC ruptures. A detailed calculation of iodine amount created by fission and released in the gap during irradiation makes it possible to show that local iodine concentration facing the pellet-to-pellet and the radial pellet cracks regions is sufficient for SCC cracks to develop in the metal. Finally, a competition between re-passivation and cracking is underscored. This results are in good agreement with the occurrence of an iodine adsorption mechanism. Adsorption could be assisted by a corrosion-deformation interaction phenomenon, and/or by the formation of solid and gaseous zirconium iodides. (author) 132 refs.

  6. Par-tjek Manualen

    DEFF Research Database (Denmark)

    Trillingsgaard, Tea; Due, Mattias Stølen; Nørr Fentz, Hanne

    Par-tjek er et tilbud til par, der ønsker at styrke forholdet og forebygge vanskeligheder. Et Par-tjek består af et indledende online spørgeskema efterfulgt at to samtaler med en psykolog eller lignende vejleder. Ved den sidste samtale modtager parret en personlig feedback-rapport, som de kan...... arbejde videre med. Samtalerne kombinerer elementer af udredning, caseformulering, psykoedukation og parterapi. Par-tjek manualen er en vejledning til fagpersoner, der arbejder med Par-tjek....

  7. Accelerated Corrosion Testing

    Science.gov (United States)

    1982-12-01

    Treaty Organization, Brussels, 1971), p. 449. 14. D. 0. Sprowls, T. J. Summerson, G. M. Ugianski, S. G. Epstein, and H. L. Craig , Jr., in Stress...National Association of Corrosion Engineers Houston, TX, 1972). 22. H. L. Craig , Jr. (ed.), Stress Corrosion-New Approaches, ASTM-STP- 610 (American...62. M. Hishida and H. Nakada, Corrosion 33 (11) 403 (1977). b3. D. C. Deegan and B. E. Wilde, Corrosion 34 (6), 19 (1978). 64. S. Orman, Corrosion Sci

  8. Approche thermodynamique de la corrosion des refractaires aluminosiliceux par le bain cryolithique : modelisation thermodynamique du systeme quaternaire reciproque AlF3-NaF-SiF 4-Al2O3-Na2O-SiO2

    Science.gov (United States)

    Lambotte, Guillaume

    The main objective of this thesis is the thermodynamic modeling of liquid and solid solutions, the stoichiometric compounds and the gaseous phase of the chemical system which represent the species involved in the corrosion of the refractory lining of the electrolysis cell. This chemical system is the quaternary reciprocal system AlF3-NaF-SiF4-Al 2O3-Na2O-SiO2 with aluminum and carbon. The modeling of the entire reciprocal system has never been realized before and is very challenging due to the nature of the oxyfluoride solution. The thermodynamic modeling is based on Gibbs free energy functions coming from the theory of solutions. The central hypothesis of this project is that, if it is possible to reproduce the strong short-range ordering observed between the ions of the liquid solution, then reasonable results will be obtained for the phase equilibria involved in this chemical system. The thermodynamic model used in this thesis is the Modified Quasichemical Model in the Quadruplet Approximation (MQMQA) which takes into account the short-range ordering between first- and also second-nearest-neighbors, and is the best suited to model the oxyfluoride liquid solution. First, the reciprocal system with the most negative Gibbs free energy change for the exchange reaction between the end-members, NaF-SiF4-Na 2O-SiO2, was modeled, allowing thus the validation of the recent modifications of the MQMQA aimed at improving the modeling of the thermodynamic properties of reciprocal solutions presenting a strong short-range order among first-nearest neighbors as well as second-nearest neighbors. In order to model this system, an estimate of the thermodynamic properties of the hypothetical SiF4 liquid was necessary. The experimental data in the binary systems NaF-SiF4 and Na2O-SiO2 are reproduced within the experimental error limits. In the reciprocal system, a group of data in conflict with all others could not be reproduced. The data considered reliable are well reproduced. A

  9. FooPar

    DEFF Research Database (Denmark)

    Hargreaves, F. P.; Merkle, D.

    2013-01-01

    We present FooPar, an extension for highly efficient Parallel Computing in the multi-paradigm programming language Scala. Scala offers concise and clean syntax and integrates functional programming features. Our framework FooPar combines these features with parallel computing techniques. FooPar......, results based on a empirical analysis on two supercomputers are given. We achieve close-to-optimal performance wrt. theoretical peak performance. Based on this result we conclude that FooPar allows programmers to fully access Scalas design features without suffering from performance drops when compared...

  10. Influence of irradiation, load history, and stress bi-axiality on initiation and propagation of stress corrosion cracks induced by iodine in zirconium alloys; Influence de l'irradiation, de l'historique de chargement et de la biaxialite des contraintes sur l'amorcage et le debut de la propagation des fissures de corrosion sous contrainte par l'iode des alliages de zirconium

    Energy Technology Data Exchange (ETDEWEB)

    Mozzani, N.; Auzoux, Q.; Le Boulch, D. [CEA Saclay, DEN, SEMI, 91 - Gif-sur-Yvette (France); Andrieu, E.; Blanc, Ch. [Universite de Toulouse, CIRIMAT, UPS/CNRS/INPT, ENSIACET, 31 - Toulouse (France); Trocellier, P. [CEA Saclay, DEN, SRMP, 91 - Gif-sur-Yvette (France)

    2010-03-15

    The authors present a research study aimed at the modelling of iodine-induced stress corrosion cracking of zirconium alloys. The aim is to develop a damage model coupled with the material mechanical behaviour, and which takes irradiation effects, load history and stress bi-axiality into account. The study comprises iodine-induced stress corrosion cracking tests of a non irradiated material and of a proton-irradiated material, a study of the mechanical behaviour and of the stress corrosion cracking behaviour of the irradiated material, and then the numerical modelling

  11. Nonconsecutive Pars Interarticularis Defects.

    Science.gov (United States)

    Elgafy, Hossein; Hart, Ryan C; Tanios, Mina

    2015-12-01

    Lumbar spondylolysis is a well-recognized condition occurring in adolescents because of repetitive overuse in sports. Nonconsecutive spondylolysis involving the lumbar spine is rare. In contrast to single-level pars defects that respond well to conservative treatment, there is no consensus about the management of multiple-level pars fractures; a few reports indicated that conservative management is successful, and the majority acknowledged that surgery is often required. The current study presents a rare case of pars fracture involving nonconsecutive segments and discusses the management options. In this case report, we review the patient's history, clinical examination, radiologic findings, and management, as well as the relevant literature. An 18-year-old man presented to the clinic with worsening lower back pain related to nonconsecutive pars fractures at L2 and L5. After 6 months of conservative management, diagnostic computed tomography-guided pars block was used to localize the symptomatic level at L2, which was treated surgically; the L5 asymptomatic pars fracture did not require surgery. At the last follow-up 2 years after surgery, the patient was playing baseball and basketball, and denied any back pain. This article reports a case of rare nonconsecutive pars fractures. Conservative management for at least 6 months is recommended. Successful management depends on the choice of appropriate treatment for each level. Single-photon emission computed tomography scan, and computed tomography-guided pars block are valuable preoperative tools to identify the symptomatic level in such a case.

  12. Corrosion inhibiting organic coatings

    Energy Technology Data Exchange (ETDEWEB)

    Sasson, E.

    1984-10-16

    A corrosion inhibiting coating comprises a mixture of waxes, petroleum jelly, a hardener and a solvent. In particular, a corrosion inhibiting coating comprises candelilla wax, carnauba wax, microcrystalline waxes, white petrolatum, an oleoresin, lanolin and a solvent.

  13. Modelling of Corrosion Cracks

    DEFF Research Database (Denmark)

    Thoft-Christensen, Palle

    Modelling of corrosion cracking of reinforced concrete structures is complicated as a great number of uncertain factors are involved. To get a reliable modelling a physical and mechanical understanding of the process behind corrosion in needed.......Modelling of corrosion cracking of reinforced concrete structures is complicated as a great number of uncertain factors are involved. To get a reliable modelling a physical and mechanical understanding of the process behind corrosion in needed....

  14. Management of Reinforcement Corrosion

    DEFF Research Database (Denmark)

    Küter, André; Geiker, Mette Rica; Møller, Per

    Reinforcement corrosion is the most important cause for deterioration of reinforced concrete structures, both with regard to costs and consequences. Thermodynamically consistent descriptions of corrosion mechanisms are expected to allow the development of innovative concepts for the management...... of reinforcement corrosion....

  15. suPAR

    DEFF Research Database (Denmark)

    Hodges, Gethin W; Bang, Casper N; Wachtell, Kristian

    2015-01-01

    The fundamental role of inflammation in cardiovascular disease (CVD) has prompted interest in numerous biomarkers that detect subclinical levels of inflammation. Soluble urokinase plasminogen activator receptor (suPAR) is a novel biomarker that correlates significantly with cardiovascular events...... and outperforms traditional markers of inflammation such as C-reactive protein (CRP) in prognosticating a range of CVDs. Furthermore, of particular interest is the suggestion that suPAR reflects a pathophysiological pathway more closely linked with subclinical organ damage than CRP. We provide the first...... comprehensive review of suPAR in CVD and explore its function and usefulness in predicting cardiovascular events....

  16. Corrosion in Electronics

    DEFF Research Database (Denmark)

    Ambat, Rajan; Gudla, Helene Virginie Conseil; Verdingovas, Vadimas

    2017-01-01

    and high density packing combined with the use of several materials, which can undergo electrochemical corrosion in the presence of water film formed due to humidity exposure and bias conditions on the PCBA surface. This article provides a short review of the corrosion reliability issues of electronics due...... to the use of electronics under varying humidity conditions. Important PCBA aspects, which are fundamental to the corrosion cell formation under humid conditions, are discussed. Effect of hygroscopic residues from the process and service and their role in assisting water film build up and corrosion...... is presented. Various failure modes resulting from the corrosion and influence factors are discussed including humid and gaseous conditions....

  17. Monitoring Microbially Influenced Corrosion

    DEFF Research Database (Denmark)

    Hilbert, Lisbeth Rischel

    Abstract Microbially influenced corrosion (MIC) of carbon steel may occur in media with microbiological activity of especially sulphate-reducing bacteria (SRB). The applicability and reliability of a number of corrosion monitoring techniques for monitoring MIC has been evaluated in experiments...... and diffusional effects and unreliable corrosion rates, when biofilm and ferrous sulphide corrosion products cover the steel surface. Corrosion rates can be overestimated by a factor of 10 to 100 by electrochemical techniques. Weight loss coupons and ER are recommended as necessary basic monitoring techniques....... EIS might be used for detection of MIC as the appearance of very large capacitances can be attributed to the combined ferrous sulphide and biofilm formation. Capacitance correlates directly with sulphide concentration in sterile sulphide media. Keywords: Corrosion monitoring, carbon steel, MIC, SRB...

  18. Microbiologically Influenced Corrosion

    Science.gov (United States)

    2015-11-05

    inCluding oil and gas, from to 2011 [2]. Over that period of time approximately of all releases were attributed to corrosion . National ;sociati<Jn...c>fComJsicmEngineers (NACE) International [3] the cost of corrosion for onshore gas and liquid nsn1ission pipelines was $7 billion. However, there...are no statistics related to microbiologically influenced (MIC) of low alloy steel pipelines. Russian inves- [4] estimated that 30% of the corrosion

  19. Coatings and Corrosion Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — Purpose: The mission of the Coatings and Corrosion Laboratory is to develop and analyze the effectiveness of innovative coatings test procedures while evaluating the...

  20. Corrosion in the oil industry

    Energy Technology Data Exchange (ETDEWEB)

    Brondel, D. (Sedco Forex, Montrouge (France)); Edwards, R. (Schlumberger Well Services, Columbus, OH (United States)); Hayman, A. (Etudes et Productions Schlumberger, Clamart (France)); Hill, D. (Schlumberger Dowell, Tulsa, OK (United States)); Mehta, S. (Schlumberger Dowell, St. Austell (United Kingdom)); Semerad, T. (Mobil Oil Indonesia, Inc., Sumatra (Indonesia))

    1994-04-01

    Corrosion costs the oil industry billions of dollars a year, a fact that makes the role of the corrosion engineer an increasingly important one. Attention is paid to how corrosion affects every aspect of exploration and production, from offshore rigs to casing. Also the role of corrosion agents such as drilling and production fluids is reviewed. Methods of control and techniques to monitor corrosion are discussed, along with an explanation of the chemical causes of corrosion. 21 figs., 32 refs.

  1. It's quicker "Par Avignon"!

    CERN Document Server

    2005-01-01

    For a few years, the CERN Library has been receiving books from the University of Hanover sent via Avignon, at least that's what it says on the envelope. Such a detour would mean that parcels were travelling 720 km more than the distance separating Geneva and Hanover, which would be a very strange state of affairs. The explanation lies in a spelling mistake. The sender has been stamping parcels with a stamp that says "Par Avignon prioritaire" (first-class via Avignon) instead of "Par Avion prioritaire" (First Class Air Mail), a source of much amusement to the librarians!

  2. Films minces de dioxyde de titane déposés sur titane par mocvd : microstructure et biocomptabilité

    OpenAIRE

    Jacota Popescu, Simona Andreia

    2008-01-01

    Des films de TiO2 variant par le teneur relative en anatase et en rutile, par la rugosité, par la mouillabilité, par la morphologie de section transverse ont été déposés sur des plaquettes de titane par MOCVD à basse pression. Du titane oxydé par anodisation ou par explosion à l'air a aussi été préparé. La capacité des dépôts à protéger le titane contre la corrosion par un fluide biologique simulé s'est avérée supérieure à celle de l'oxyde naturel. Le comportement des fibroblastes et d'ostéob...

  3. suPAR

    DEFF Research Database (Denmark)

    Eugen-Olsen, Jesper; Giamarellos-Bourboulis, Evangelos J

    2015-01-01

    promising biomarker is soluble urokinase-type plasminogen activator receptor (suPAR). Three studies in large populations of critically ill patients and patients admitted to the emergency department have shown that concentrations >12ng/mL can safely predict unfavourable outcome. This review presents...

  4. Corrosion evaluation technology

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Uh Chul; Han, Jeong Ho; Nho, Kye Ho; Lee, Eun Hee; Kim, Hong Pyo; Hwang, Seong Sik; Lee, Deok Hyun; Hur, Do Haeng; Kim, Kyung Mo

    1997-09-01

    A multifrequency ACPD system was assembled which can measure very small crack. Stress corrosion cracking test system with SSRT operating high temperature was installed. Stress corrosion cracking test of newly developed alloy 600 and existing alloy 600 was carried out in steam atmosphere of 400 deg C. No crack was observed in both materials within a test period of 2,000 hrs. Corrosion fatigue test system operating at high temperature was installed in which fatigue crack was measured by CDPD. Lead enhanced the SCC of the Alloy 600 in high temperature water, had a tendency to modify a cracking morphology from intergranular to transgranular. Pit initiation preferentially occurred at Ti-rich carbide. Resistance to pit initiation decreased with increasing temperature up to 300 deg C. Test loop for erosion corrosion was designed and fabricated. Thin layer activation technique was very effective in measuring erosion corrosion. Erosion corrosion of a part of secondary side pipe was evaluated by the Check Family Codes of EPRI. Calculated values of pipe thickness by Check Family Codes coincided with the pipe thickness measured by UT with an error of {+-} 20%. Literature review on turbine failure showed that failure usually occurred in low pressure turbine rotor disc and causes of failure are stress corrosion cracking and corrosion fatigue. (author). 12 refs., 20 tabs., 77 figs.

  5. Monitoring corrosion rates and localised corrosion in low conductivity water

    DEFF Research Database (Denmark)

    Hilbert, Lisbeth Rischel

    2006-01-01

    Monitoring of low corrosion rates and localised corrosion in a media with low conductivity is a challenge. In municipal district heating, quality control may be improved by implementing on-line corrosion monitoring if a suitable technique can be identified to measure both uniform and localised...... corrosion. Electrochemical techniques (LPR, EIS, crevice corrosion current) as well as direct measurement techniques (high-sensitive electrical resistance, weight loss) have been applied in operating plants. Changes in the corrosion processes are best monitored in non-aggressive, low conductivity media...... with sensitive electrical resistance technique and crevice corrosion current measurements....

  6. Automated Methods Of Corrosion Measurements

    DEFF Research Database (Denmark)

    Bech-Nielsen, Gregers; Andersen, Jens Enevold Thaulov; Reeve, John Ch

    1997-01-01

    The chapter describes the following automated measurements: Corrosion Measurements by Titration, Imaging Corrosion by Scanning Probe Microscopy, Critical Pitting Temperature and Application of the Electrochemical Hydrogen Permeation Cell.......The chapter describes the following automated measurements: Corrosion Measurements by Titration, Imaging Corrosion by Scanning Probe Microscopy, Critical Pitting Temperature and Application of the Electrochemical Hydrogen Permeation Cell....

  7. PAR Loop Schedule Review

    Energy Technology Data Exchange (ETDEWEB)

    Schaffer, Jr.; W.F.

    1958-04-30

    The schedule for the installation of the PAR slurry loop experiment in the South Facility of the ORR has been reviewed and revised. The design, fabrications and Installation is approximately two weeks behind schedule at this time due to many factors; however, indications are that this time can be made up. Design is estimated to be 75% complete, fabrication 32% complete and installation 12% complete.

  8. Carbon Dioxide Corrosion:

    DEFF Research Database (Denmark)

    Fosbøl, Philip Loldrup

    2008-01-01

    consists mainly of CO2-Na2CO3-NaHCO3-MEG-H2O. Sodium is injected in the pipelines as NaOH in order to pH-stabilize the pipeline to avoid corrosion and MEG is injected in order to prevent gas hydrates. There are a great number of models available in the literature which may predict CO2 corrosion...

  9. Corrosion on spinal implants.

    Science.gov (United States)

    Kirkpatrick, John S; Venugopalan, Ramakrishna; Beck, Preston; Lemons, Jack

    2005-06-01

    Modular spine implants are used as an aid to obtaining fusion, but fretting and corrosion occur between modular components in a biologic environment. Forty-eight spinal implant constructs manufactured by a variety of companies were retrieved from 47 patients and were subjected to surface analysis stereomicroscopy. Stainless-steel implants (n = 23) had either semirigid constructs with mild or no surface alteration (n = 7) or rigid constructs with moderate or severe alteration (n = 16). Surface damage was consistent with previously observed mechanically assisted crevice corrosion phenomena. Titanium alloy implants (n = 25) showed no significant corrosion but had three constructs with fatigue failure of anchoring screws. One cobalt alloy construct showed no evidence of corrosion. Long-term effects of fretting and corrosion are unclear, and minimization of these phenomena seems justified. Selection of modular components with similar materials and surface finish may help the surgeon minimize localized changes over time. Stainless-steel implants with rigid interconnections and those with different surface finishes between rods and connectors are most susceptible to corrosion.

  10. Modelling reinforcement corrosion in concrete

    DEFF Research Database (Denmark)

    Michel, Alexander; Geiker, Mette Rica; Stang, Henrik

    2012-01-01

    A physio-chemical model for the simulation of reinforcement corrosion in concrete struc-tures was developed. The model allows for simulation of initiation and subsequent propaga-tion of reinforcement corrosion. Corrosion is assumed to be initiated once a defined critical chloride threshold...... is reached causing the formation of anodic and cathodic regions along the reinforcement. Critical chloride thresholds, randomly distributed along the reinforcement sur-face, link the initiation and propagation phase of reinforcement corrosion. To demonstrate the potential use of the developed model......, a numerical example is pre-sented, that illustrates the formation of corrosion cells as well as propagation of corrosion in a reinforced concrete structure....

  11. Parálisis cerebral :

    OpenAIRE

    Aguado Navarro, Ana Belén

    2013-01-01

    Se aborda el tema de la parálisis cerebral definiendo qué es, clasificando los tipos de parálisis dependiendo de la afectación y las características principales. Se explican algunos de sus tratamientos, se dan sistemas alternativos y/o aumentativos de comunicación para un alumno con PC (parálisis cerebral).

  12. pitting corrosion susceptibility pitting corrosion susceptibility of aisi ...

    African Journals Online (AJOL)

    eobe

    Abstract. The susceptibility of austenitic (AISI 301) stainless steel to pitting corrosion was evaluated in sodium chloride. (NaCl) solutions ... AISI 301 steel suffers from pitting corrosion in all the investigated solutions. AISI 301 steel suffers from ..... [1] Ijeomah, M.N.C. Elements of Corrosion and Protection. Theory, Auto Century ...

  13. Brulures par Diluant

    Science.gov (United States)

    Benbrahim, A.; Jerrah, H.; Diouri, M.; Bahechar, N.; Boukind, E.H.

    2009-01-01

    Summary La flamme de diluant est une cause non rare de brûlure dans le contexte marocain. Nous avons jugé intéressant de faire une étude épidémiologique sur la brûlure par flamme de diluant (BFD) au centre national des brûlés (CNB) du CHU Ibn-Rochd de Casablanca. Ce travail a été réalisé sur une période de 10 mois (septembre 2007/juin 2008). Le but du travail est de montrer les caractéristiques de ce type de brûlures pour les prévenir et ce par l'information sur le diluant, produit causant ces brûlures, et ses différents dangers, la brûlure notamment. Durant cette période, nous avons colligé 17 cas de BFD sur un total de 356 patients admis au CNB pour brûlures aiguës toute étiologie confondue. La moyenne d'age des patients concernés est de 32 ans. Ils sont presque tous de sexe masculin (16 hommes/1 femme) et ont des antécédents de toxicomanie et/ou de délinquance. Tous nos patients sont de bas niveau socio-économique et habitent dans des bidonvilles pour la plupart. La brûlure est souvent secondaire à une agression dans la rue (92% des cas). Concernant les caractéristiques de la brûlure, la surface cutanée brûlée moyenne est de 23%; elle est souvent profonde et siège surtout au niveau des membres supérieurs et du tronc. PMID:21991179

  14. Corrosion-resistant metal surfaces

    Science.gov (United States)

    Sugama, Toshifumi [Wading River, NY

    2009-03-24

    The present invention relates to metal surfaces having thereon an ultrathin (e.g., less than ten nanometer thickness) corrosion-resistant film, thereby rendering the metal surfaces corrosion-resistant. The corrosion-resistant film includes an at least partially crosslinked amido-functionalized silanol component in combination with rare-earth metal oxide nanoparticles. The invention also relates to methods for producing such corrosion-resistant films.

  15. Atmospheric corrosion of mild steel

    OpenAIRE

    Morcillo, M.; de la Fuente, D.; Díaz, I.; Cano, H.

    2011-01-01

    The atmospheric corrosion of mild steel is an extensive topic that has been studied by many authors in different regions throughout the world. This compilation paper incorporates relevant publications on the subject, in particular about the nature of atmospheric corrosion products, mechanisms of atmospheric corrosion and kinetics of the atmospheric corrosion process, paying special attention to two matters upon which relatively less information has been published: a) the morphology of steel c...

  16. Atmospheric corrosion of mild steel

    OpenAIRE

    Morcillo, Manuel; Fuente, Daniel de la; Díaz, Iván; Cano, H.

    2011-01-01

    The atmospheric corrosion of mild steel is an extensive topic that has been studied by many authors in different regions throughout the world. This compilation paper incorporates relevant publications on the subject, in particular about the nature of atmospheric corrosion products, mechanisms of atmospheric corrosion and kinetics of the atmospheric corrosion process, paying special attention to two matters upon which relatively less information has been published: a) the morpholog...

  17. Présentation des phénomènes de corrosion et des différents moyens de lutte disponibles. Description of Corrosion Phenomena and Different Ways of Combating Them.

    Directory of Open Access Journals (Sweden)

    Crolet J. L.

    2006-11-01

    Full Text Available Cet article donne une présentation générale des phénomènes de corrosion des matériaux métalliques. II s'attache à montrer comment les moyens de lutte contre la corrosion découlent très naturellement de la bonne compréhension de ces phénomènes.Les aspects électrochimiques, indispensables pour cette compréhension, sont présentés de manière aussi directe et brève que possible. Les divers modes de résistance à la corrosion sont décrits, qu'il s'agisse de modes a naturels » comme l'inertie chimique, la passivité, la pseudo-passivité ou les couches de patine, ou bien encore de modes a provoqués » comme le contrôle du milieu corrosif, l'inhibition, la protection cathodique ou la protection par revêtement.Enfin, les principales interactions entre effets mécaniques et corrosion sont abordées, et en particulier l'érosion-corrosion et la fragilisation par H.S. Des conjugaisons de phénomènes comme la corrosion galvanique, la corrosion inter-granulaire, la corrosion bactérienne sont également présentées. This article gives a general description of corrosion phenomena affecting metallic materials. It attempts ta show how corrosion control and prevention methods quite naturally require a good understanding of these phenomena.The electrochemical aspects indispensable for this understanding are described as directly and briefly as possible.Various types of corrosion resistance are described, whether concerning a natural » types such as chemical inertia, passivity, pseudo-passivity or patina loyers, or else c induced types » such as contrat of the corrosive medium, inhibition, cathodic protec-tion or protection by coating.The principal` interactions between mechanical effects and corrosion are taken up, and especially erosion corrosion and H2S embrittlement. Combinations of pheno-mena are also described, such as galvanic corrosion, intergranular corrosion and bacterial corrosion.

  18. Plastics for corrosion inhibition

    CERN Document Server

    Goldade, Victor A; Makarevich, Anna V; Kestelman, Vladimir N

    2005-01-01

    The development of polymer composites containing inhibitors of metal corrosion is an important endeavour in modern materials science and technology. Corrosion inhibitors can be located in a polymer matrix in the solid, liquid or gaseous phase. This book details the thermodynamic principles for selecting these components, their compatibility and their effectiveness. The various mechanisms of metal protection – barrier, inhibiting and electromechanical – are considered, as are the conflicting requirements placed on the structure of the combined material. Two main classes of inhibited materials (structural and films/coatings) are described in detail. Examples are given of structural plastics used in friction units subjected to mechano-chemical wear and of polymer films/coatings for protecting metal objects against corrosion.

  19. Thin film corrosion. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Raut, M.K.

    1980-06-01

    Corrosion of chromium/gold (Cr/Au) thin films during photolithography, prebond etching, and cleaning was evaluated. Vapors of chromium etchant, tantalum nitride etchant, and especially gold etchant were found to corrosively attack chromium/gold films. A palladium metal barrier between the gold and chromium layers was found to reduce the corrosion from gold etchant.

  20. Insights into ParB spreading from the complex structure of Spo0J and parS.

    Science.gov (United States)

    Chen, Bo-Wei; Lin, Ming-Hsing; Chu, Chen-Hsi; Hsu, Chia-En; Sun, Yuh-Ju

    2015-05-26

    Spo0J (stage 0 sporulation protein J, a member of the ParB superfamily) is an essential component of the ParABS (partition system of ParA, ParB, and parS)-related bacterial chromosome segregation system. ParB (partition protein B) and its regulatory protein, ParA, act cooperatively through parS (partition S) DNA to facilitate chromosome segregation. ParB binds to chromosomal DNA at specific parS sites as well as the neighboring nonspecific DNA sites. Various ParB molecules can associate together and spread along the chromosomal DNA. ParB oligomer and parS DNA interact together to form a high-order nucleoprotein that is required for the loading of the structural maintenance of chromosomes proteins onto the chromosome for chromosomal DNA condensation. In this report, we characterized the binding of parS and Spo0J from Helicobacter pylori (HpSpo0J) and solved the crystal structure of the C-terminal domain truncated protein (Ct-HpSpo0J)-parS complex. Ct-HpSpo0J folds into an elongated structure that includes a flexible N-terminal domain for protein-protein interaction and a conserved DNA-binding domain for parS binding. Two Ct-HpSpo0J molecules bind with one parS. Ct-HpSpo0J interacts vertically and horizontally with its neighbors through the N-terminal domain to form an oligomer. These adjacent and transverse interactions are accomplished via a highly conserved arginine patch: RRLR. These interactions might be needed for molecular assembly of a high-order nucleoprotein complex and for ParB spreading. A structural model for ParB spreading and chromosomal DNA condensation that lead to chromosome segregation is proposed.

  1. Corrosion of bio implants

    Indian Academy of Sciences (India)

    Chemical stability, mechanical behaviour and biocompatibility in body fluids and tissues are the basic requirements for successful application of implant materials in bone fractures and replacements. Corrosion is one of the major processes affecting the life and service of orthopaedic devices made of metals and alloys used ...

  2. Smart Coatings for Corrosion Protection

    Science.gov (United States)

    Calle, Luz Marina; Li, Wendy; Buhrow, Jerry W.; Johnsey, Marissa N.

    2016-01-01

    Nearly all metals and their alloys are subject to corrosion that causes them to lose their structural integrity or other critical functionality. It is essential to detect corrosion when it occurs, and preferably at its early stage, so that action can be taken to avoid structural damage or loss of function. Protective coatings are the most commonly used method of corrosion control. However, progressively stricter environmental regulations have resulted in the ban of many commercially available corrosion protective coatings due to the harmful effects of their solvents or corrosion inhibitors. This work concerns the development of a multifunctional, smart coating for the autonomous control of corrosion. This coating is being developed to have the inherent ability to detect the chemical changes associated with the onset of corrosion and respond autonomously to indicate it and control it.

  3. Datation par thermoluminescence

    Directory of Open Access Journals (Sweden)

    1976-01-01

    Full Text Available Depuis 1953, de nombreux chercheurs se sont intéressés à la datation par thermoluminescence de minéraux anciennement brûlés ou cuits. Dans ce travail, après avoir rappelé quelques principes physiques de la thermoluminescence, on présente cette méthode de datation en mettant l'accent sur le mécanisme thermoluminescent dans une poterie. Ainsi la dose d'irradiation reçue par le matériau étant proportionnelle au temps écoulé depuis le 'zéro archéologique', il est possible de déterminer 'la dose archéologique' et d'en déduire l'âge de l'échantillon après avoir calculé la dose d'irradiation annuelle. La réalisation pratique d'un tel ensemble de mesure est cependant très ardue. Dans un prochain article, E. A. Decamps et A. Roman montreront des résultats relatifs à la thermoluminescence d'échantillons de quartz naturels, purs et dopés et la mise au point d'une nouvelle méthode de datation. Desde 1953, muchos investigadores se han interesado en la datación por termoluminiscencia de minerales antiguamente quemados o cocidos. Dentro de este trabajo, luego de haber recordado algunos principios físicos de la termoluminiscencia, se presenta este método de datación poniendo mayor atención en el mecanismo termoluminescente en una vasija de metal o de barro. Siendo proporcional la dosis de irradiación recibida al tiempo transcurrido desde el 'cero arqueológico', es posible determinar 'la dosis arqueológica', y deducir la edad de la muestra luego de haber calculado la dosis de irradiación anual. La realización práctica de un trabajo de tal dimensión es sin embargo muy ardua. En un próximo artículo, E. A. Decamps y A. Román presentarán los resultados relativos a la termoluminiscencia de muestras de cuarzo naturales, puras y dopadas y la elaboración de un nuevo método de datación. Since 1953, a number of scientists have been concerned with the use of thermoluminescence for the dating of burned or fired minerals

  4. Elusloom lennukiga puhkusele / Inge Parring

    Index Scriptorium Estoniae

    Parring, Inge

    2003-01-01

    Ilmunud ka: Delovõje Vedomosti 1. okt. lk. 13. Air Cargo Estonia/ACE Logisticsi müügijuht Inge Parring tutvustab elusloomade transpordivõimalusi. Vt. samas: Loomade transportimiseks vajalikud dokumendid

  5. Corrosion Evaluation and Corrosion Control of Steam Generators

    Energy Technology Data Exchange (ETDEWEB)

    Maeng, W. Y.; Kim, U. C.; Sung, K. W.; Na, J. W.; Lee, Y. H.; Lee, D. H.; Kim, K. M

    2008-06-15

    Corrosion damage significantly influences the integrity and efficiency of steam generator. Corrosion problems of steam generator are unsolved issues until now even though much effort is made around world. Especially the stress corrosion cracking of heat exchange materials is the first issue to be solved. The corrosion protection method of steam generator is important and urgent for the guarantee of nuclear plant's integrity. The objectives of this study are 1) to evaluate the corrosion properties of steam generator materials, 2) to optimize the water chemistry of steam generator and 3) to develop the corrosion protection method of primary and secondary sides of steam generator. The results will be reflected to the water chemistry guideline for improving the integrity and efficiency of steam generator in domestic power plants.

  6. suPAR: the molecular crystal ball

    DEFF Research Database (Denmark)

    Thunø, Maria; Macho, Betina; Eugen-Olsen, Jesper

    2009-01-01

    soluble urokinase Plasminogen Activator Receptor (suPAR) levels reflect inflammation and elevated suPAR levels are found in several infectious diseases and cancer. suPAR exists in three forms; suPAR(I-III), suPAR(II-III) and suPAR(I) which show different properties due to structural differences. ...... in inflammation and pathogenic processes. We focus on the molecular mechanisms of the suPAR fragments and the link to the inflammatory process,as this could lead to medical applications in infectious and pathological conditions........ Studies suggest that full-length suPAR is a regulator of uPAR/uPA by actingas uPA-scavenger, whereas the cleaved suPAR(II-III) act as a chemotactic agent promoting the immune response via the SRSRY sequence in the linker-region. This review focus on the various suPAR fragments and their involvement...

  7. Immunopathogenic Background of Pars Planitis.

    Science.gov (United States)

    Przeździecka-Dołyk, Joanna; Węgrzyn, Agnieszka; Turno-Kręcicka, Anna; Misiuk-Hojło, Marta

    2016-04-01

    Pars planitis is defined as an intermediate uveitis of unknown background of systemic disease with characteristic formations such as vitreous snowballs, snowbanks and changes in peripheral retina. The incidence of pars planitis varies 2.4-15.4 % of the uveitis patients. The pathogenesis of the disease is to be determined in future. Clinical and histopathological findings suggest an autoimmune etiology, most likely as a reaction to endogenous antigen of unknown source, with T cells predominant in both vitreous and pars plana infiltrations. T cells subsets play an important role as a memory-effector peripheral cell. Snowbanks are formed as an effect of post inflammatory glial proliferation of fibrous astrocytes. There is also a genetic predisposition for pars planitis by human leukocyte antigen and several other genes. A coexistence of multiple sclerosis and optic neuritis has been described in numerous studies. Epiretinal membrane, cataract, cystoid macular edema, retinal detachment, retinal vasculitis, neovascularization, vitreous peripheral traction, peripheral hole formation, vitreous hemorrhage, disc edema are common complications observed in pars planitis. There is a need to expand the knowledge of the pathogenic and immunologic background of the pars planitis to create an accurate pharmacological treatment.

  8. DWPF corrosion study

    Energy Technology Data Exchange (ETDEWEB)

    Selby, C.L.

    1986-12-17

    Corrosion of candidate alloys for the DWPF SRAT, SME, and melter was tested in the large (1/3 scale) SRAT/SME, the 200th scale SRAT/SME, and the LSFM. Flat or twisted coupons with or without a weld bead and U-bend specimens (specimens bent into a ''U'' shape and bolted together at the ends to stress the bend area) were installed on racks that ensured electrical isolation to avoid galvanic effects. Teflon/reg sign/ washers isolated the low temperature exposure racks and ceramic washers isolated the high temperature exposure racks. Serrated washers simulated crevices, but crevice corrosion did not result. 9 refs., 9 tabs.

  9. Corrosion studies with pixe

    Science.gov (United States)

    Anwar Chaudhri, M.; Crawford, A.

    1981-03-01

    To investigate the possible causes of corrosion of some of the tooth paste tubes of a major international cosmetic product manufacturer, the elemental compositions of corroded and clean unused tubes were compared, using PIXE. It was observed that some of the corroded tubes contained much higher amounts of Ti, Fe, Ga and Zn than the clean tubes, while the concentrations of Cr and Ni showed no significant difference between the two types of tubes. Only certain regions of one of the tubes were found to contain higher concentrations of Cu. Those regions were badly corroded and had the highest concentrations of Ti, Fe, Ga and Zn, too. It is suggested that the presence of higher amounts of Ti, Fe, Ga and Zn, and especially of Cu, in the aluminium sheets used to manufacture the tooth paste tubes, may be one of the reasons for the corrosion of some of the tooth paste tubes.

  10. Corrosion Protection of Aluminum

    Science.gov (United States)

    Dalrymple, R. S.; Nelson, W. B.

    1963-07-01

    Treatment of aluminum-base metal surfaces in an autoclave with an aqueous chromic acid solution of 0.5 to 3% by weight and of pH below 2 for 20 to 50 hrs at 160 to 180 deg C produces an extremely corrosion-resistant aluminum oxidechromium film on the surface. A chromic acid concentration of 1 to 2% and a pH of about 1 are preferred.

  11. Automated methods of corrosion measurement

    DEFF Research Database (Denmark)

    Andersen, Jens Enevold Thaulov; Bech-Nielsen, Gregers; Reeve, John Ch

    1997-01-01

    Measurements of corrosion rates and other parameters connected with corrosion processes are important, first as indicators of the corrosion resistance of metallic materials and second because such measurements are based on general and fundamental physical, chemical, and electrochemical relations....... Hence improvements and innovations in methods applied in corrosion research are likeliy to benefit basic disciplines as well. A method for corrosion measurements can only provide reliable data if the beckground of the method is fully understood. Failure of a method to give correct data indicates a need...... to revise assumptions regarding the basis of the method, which sometimes leads to the discovery of as-yet unnoticed phenomena. The present selection of automated methods for corrosion measurements is not motivated simply by the fact that a certain measurement can be performed automatically. Automation...

  12. Nuclear corrosion science and engineering

    CERN Document Server

    2012-01-01

    Understanding corrosion mechanisms, the systems and materials they affect, and the methods necessary for accurately measuring their incidence is of critical importance to the nuclear industry for the safe, economic and competitive running of its plants. This book reviews the fundamentals of nuclear corrosion. Corrosion of nuclear materials, i.e. the interaction between these materials and their environments, is a major issue for plant safety as well as for operation and economic competitiveness. Understanding these corrosion mechanisms, the systems and materials they affect, and the methods to accurately measure their incidence is of critical importance to the nuclear industry. Combining assessment techniques and analytical models into this understanding allows operators to predict the service life of corrosion-affected nuclear plant materials, and to apply the most appropriate maintenance and mitigation options to ensure safe long term operation. This book critically reviews the fundamental corrosion mechani...

  13. Corrosion in supercritical fluids

    Energy Technology Data Exchange (ETDEWEB)

    Propp, W.A.; Carleson, T.E.; Wai, Chen M.; Taylor, P.R.; Daehling, K.W.; Huang, Shaoping; Abdel-Latif, M.

    1996-05-01

    Integrated studies were carried out in the areas of corrosion, thermodynamic modeling, and electrochemistry under pressure and temperature conditions appropriate for potential applications of supercritical fluid (SCF) extractive metallurgy. Carbon dioxide and water were the primary fluids studied. Modifiers were used in some tests; these consisted of 1 wt% water and 10 wt% methanol for carbon dioxide and of sulfuric acid, sodium sulfate, ammonium sulfate, and ammonium nitrate at concentrations ranging from 0.00517 to 0.010 M for the aqueous fluids. The materials studied were Types 304 and 316 (UNS S30400 and S31600) stainless steel, iron, and AISI-SAE 1080 (UNS G10800) carbon steel. The thermodynamic modeling consisted of development of a personal computer-based program for generating Pourbaix diagrams at supercritical conditions in aqueous systems. As part of the model, a general method for extrapolating entropies and related thermodynamic properties from ambient to SCF conditions was developed. The experimental work was used as a tool to evaluate the predictions of the model for these systems. The model predicted a general loss of passivation in iron-based alloys at SCF conditions that was consistent with experimentally measured corrosion rates and open circuit potentials. For carbon-dioxide-based SCFs, measured corrosion rates were low, indicating that carbon steel would be suitable for use with unmodified carbon dioxide, while Type 304 stainless steel would be suitable for use with water or methanol as modifiers.

  14. Corrosion Chemistry in Inhibited HDA.

    Science.gov (United States)

    1980-11-30

    Section 3 3.1 JM West, Corrosion and Electrodeposition Processes, Van Nostrand, 1970. 3.2 M Pourbaix, Atlas of Electrochemical Equilibria , Pergamon...potential inhibitors of aluminium and stainless steel corrosion in HDA has been studied by n.m.r. spectroscopy, electrochemical techniques, X-ray...Polarisation theory 24 (c) Estimation of corrosion rate 27 (d) Passivation 30 (e) Film breakdown 33 3.2 Electrochemical Instrumentation 35 The potentiostat 35

  15. Automated Methods of Corrosion Measurements

    DEFF Research Database (Denmark)

    Andersen, Jens Enevold Thaulov

    1997-01-01

    electrochemical measurements as well as elemental analysis look very promising for elucidating corrosion reaction mechanisms. The study of initial surface reactions at the atomic or submicron level is becoming an important field of research in the understanding of corrosion processes. At present, mainly two...... scanning microscope techniques are employed investigating corrosion processes, and usually in situ: in situ scanning tunneling microscopy (in situ STM) and in situ scanning force microscopy (in situ AFM). It is these techniques to which attention is directed here....

  16. Microbiologically Influenced Corrosion: an Update

    Science.gov (United States)

    2014-01-01

    of ALWC. Gu67 demon- strated that starved (no organic carbon in the medium) SRB biofilms were more aggressive towards carbon steel than the same SRB...31. K. Ito, R. Matasuhashi, M. Kato, O. Miki, H. Kihira, K. Wantanabe and P. Baker: ‘Potential ennoblement of stainless steel by marine biofilm ...corrosion than in the presence of oxidisable carbon. Non-corrosive biofilms can become corrosive with subtle changes in the environment, e.g., addition of

  17. Corrosion Monitors for Embedded Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, Alex L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Pfeifer, Kent B. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Casias, Adrian L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Howell, Stephen W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Sorensen, Neil R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Missert, Nancy A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-05-01

    We have developed and characterized novel in-situ corrosion sensors to monitor and quantify the corrosive potential and history of localized environments. Embedded corrosion sensors can provide information to aid health assessments of internal electrical components including connectors, microelectronics, wires, and other susceptible parts. When combined with other data (e.g. temperature and humidity), theory, and computational simulation, the reliability of monitored systems can be predicted with higher fidelity.

  18. Panel report on corrosion in energy systems

    Energy Technology Data Exchange (ETDEWEB)

    None

    1979-06-01

    Corrosion problems in high-temperature (non aqueous) energy systems, corrosion in aqueous energy systems and institutional problems inhibiting the development of corrosion science and engineering are discussed. (FS)

  19. Mechanisms of metal dusting corrosion

    DEFF Research Database (Denmark)

    Hummelshøj, Thomas Strabo

    In this thesis the early stages of metal dusting corrosion is addressed; the development of carbon expanded austenite, C, and the decomposition hereof into carbides. Later stages of metal dusting corrosion are explored by a systematic study of stainless steel foils exposed to metal dusting...... influence of oxygen and carbon on the metal dusting corrosion is explored. The results indicate that exposure to metal dusting conditions have a detrimental effect on the resistance against oxidation and, conversely, that exposure to oxidation has a detrimental effect on the resistance towards metal dusting....... Consequently, a combination of carburizing and oxidizing conditions has a strong mutual catalyzing effect on the metal dusting corrosion....

  20. Evaluation of steel corrosion by numerical analysis

    OpenAIRE

    Kawahigashi, Tatsuo

    2017-01-01

    Recently, various non-destructive and numerical methods have been used and many cases of steel corrosion are examined. For example, methods of evaluating corrosion through various numerical methods and evaluating macrocell corrosion and micro-cell corrosion using measurements have been proposed. However, there are few reports on estimating of corrosion loss with distinguishing the macro-cell and micro-cell corrosion and with resembling an actuality phenomenon. In this study, for distinguishin...

  1. phytochemicals as green corrosion inhibitors in various corrosive ...

    African Journals Online (AJOL)

    Mgina

    replace toxic inhibitors used for mitigation of corrosion of various metals and alloys in aqueous solutions. Plants represent a class of ... structures causing economic consequences in terms of repair, replacement, product ... Buchweishaija – Physicochemicals as green corrosion inhibitors … 78 rather complex molecular ...

  2. Facilities Corrosion Impacts: When Corrosion Wins, the Mission Ends

    Science.gov (United States)

    2010-02-10

    Product/Results - Technology demonstrations and implementations at DoD Installations. - Cost and performance reports. - Recommendations for design ...guidance updates– ACSIM Installation Design Standards Payoff Service life extension of aging mission critical utilities and structures. Reduction in...corrosion.  Technology- Microcapsules in the form of microscopic spheres on the order of 50 to 150 microns in diameter containing corrosion-inhibiting

  3. Archaeological analogs and corrosion; Analogues archeologiques et corrosion

    Energy Technology Data Exchange (ETDEWEB)

    David, D

    2008-07-01

    In the framework of the high level and long life radioactive wastes disposal deep underground, the ANDRA built a research program on the material corrosion. In particular they aim to design containers for a very long time storage. Laboratory experiments are in progress and can be completed by the analysis of metallic archaeological objects and their corrosion after hundred years. (A.L.B.)

  4. Phytochemicals as Green Corrosion Inhibitors in Various Corrosive ...

    African Journals Online (AJOL)

    There is an intensive effort underway to develop new plant origin corrosion inhibitors for metal subjected to various environmental conditions. These efforts have been motivated by the desire to replace toxic inhibitors used for mitigation of corrosion of various metals and alloys in aqueous solutions. Plants represent a class ...

  5. Designing Tone Reservation PAR Reduction

    Directory of Open Access Journals (Sweden)

    Johansson Albin

    2006-01-01

    Full Text Available Tone reservation peak-to-average (PAR ratio reduction is an established area when it comes to bringing down signal peaks in multicarrier (DMT or OFDM systems. When designing such a system, some questions often arise about PAR reduction. Is it worth the effort? How much can it give? How much does it give depending on the parameter choices? With this paper, we attempt to answer these questions without resolving to extensive simulations for every system and every parameter choice. From a specification of the allowed spectrum, for instance prescribed by a standard, including a PSD-mask and a number of tones, we analytically predict achievable PAR levels, and thus implicitly suggest parameter choices. We use the ADSL2 and ADSL2+ systems as design examples.

  6. General Corrosion and Localized Corrosion of Waste Package Outer Barrier

    Energy Technology Data Exchange (ETDEWEB)

    K.G. Mon

    2004-10-01

    The waste package design for the License Application is a double-wall waste package underneath a protective drip shield (BSC 2004 [DIRS 168489]; BSC 2004 [DIRS 169480]). The purpose and scope of this model report is to document models for general and localized corrosion of the waste package outer barrier (WPOB) to be used in evaluating waste package performance. The WPOB is constructed of Alloy 22 (UNS N06022), a highly corrosion-resistant nickel-based alloy. The inner vessel of the waste package is constructed of Stainless Steel Type 316 (UNS S31600). Before it fails, the Alloy 22 WPOB protects the Stainless Steel Type 316 inner vessel from exposure to the external environment and any significant degradation. The Stainless Steel Type 316 inner vessel provides structural stability to the thinner Alloy 22 WPOB. Although the waste package inner vessel would also provide some performance for waste containment and potentially decrease the rate of radionuclide transport after WPOB breach before it fails, the potential performance of the inner vessel is far less than that of the more corrosion-resistant Alloy 22 WPOB. For this reason, the corrosion performance of the waste package inner vessel is conservatively ignored in this report and the total system performance assessment for the license application (TSPA-LA). Treatment of seismic and igneous events and their consequences on waste package outer barrier performance are not specifically discussed in this report, although the general and localized corrosion models developed in this report are suitable for use in these scenarios. The localized corrosion processes considered in this report are pitting corrosion and crevice corrosion. Stress corrosion cracking is discussed in ''Stress Corrosion Cracking of the Drip Shield, the Waste Package Outer Barrier, and the Stainless Steel Structural Material'' (BSC 2004 [DIRS 169985]).

  7. Increased ParB level affects expression of stress response, adaptation and virulence operons and potentiates repression of promoters adjacent to the high affinity binding sites parS3 and parS4 in Pseudomonas aeruginosa.

    Directory of Open Access Journals (Sweden)

    Adam Kawalek

    Full Text Available Similarly to its homologs in other bacteria, Pseudomonas aeruginosa partitioning protein ParB facilitates segregation of newly replicated chromosomes. Lack of ParB is not lethal but results in increased frequency of anucleate cells production, longer division time, cell elongation, altered colony morphology and defective swarming and swimming motility. Unlike in other bacteria, inactivation of parB leads to major changes of the transcriptome, suggesting that, directly or indirectly, ParB plays a role in regulation of gene expression in this organism. ParB overproduction affects growth rate, cell division and motility in a similar way as ParB deficiency. To identify primary ParB targets, here we analysed the impact of a slight increase in ParB level on P. aeruginosa transcriptome. ParB excess, which does not cause changes in growth rate and chromosome segregation, significantly alters the expression of 176 loci. Most notably, the mRNA level of genes adjacent to high affinity ParB binding sites parS1-4 close to oriC is reduced. Conversely, in cells lacking either parB or functional parS sequences the orfs adjacent to parS3 and parS4 are upregulated, indicating that direct ParB- parS3/parS4 interactions repress the transcription in this region. In addition, increased ParB level brings about repression or activation of numerous genes including several transcriptional regulators involved in SOS response, virulence and adaptation. Overall, our data support the role of partitioning protein ParB as a transcriptional regulator in Pseudomonas aeruginosa.

  8. DPC materials and corrosion environments.

    Energy Technology Data Exchange (ETDEWEB)

    Ilgen, Anastasia Gennadyevna; Bryan, Charles R.; Teich-McGoldrick, Stephanie; Hardin, Ernest

    2014-10-01

    After an exposition of the materials used in DPCs and the factors controlling material corrosion in disposal environments, a survey is given of the corrosion rates, mechanisms, and products for commonly used stainless steels. Research needs are then identified for predicting stability of DPC materials in disposal environments. Stainless steel corrosion rates may be low enough to sustain DPC basket structural integrity for performance periods of as long as 10,000 years, especially in reducing conditions. Uncertainties include basket component design, disposal environment conditions, and the in-package chemical environment including any localized effects from radiolysis. Prospective disposal overpack materials exist for most disposal environments, including both corrosion allowance and corrosion resistant materials. Whereas the behavior of corrosion allowance materials is understood for a wide range of corrosion environments, demonstrating corrosion resistance could be more technically challenging and require environment-specific testing. A preliminary screening of the existing inventory of DPCs and other types of canisters is described, according to the type of closure, whether they can be readily transported, and what types of materials are used in basket construction.

  9. corrosion inhibitor for carbon steels

    African Journals Online (AJOL)

    potentiodynamic polarisation techniques. It was found that. CNSL reduces the extent of the electrochemical processes taking place on carbon steel undergoing corrosion. The corrosion rate of the carbon steel was reduced by over 92 % when only 300 ppm of CNSL was applied. This indicates that. CNSL is a potential ...

  10. Polymeric materials for corrosion control

    Energy Technology Data Exchange (ETDEWEB)

    Dickie, R.A.; Floyd, F.L. (eds.)

    1986-01-01

    This volume of 31 typescript chapters is concerned with polymeric coatings. The papers originated in a symposium held in Chicago in 1985 and are divided into three categories: Evaluation of Material Performance; Adhesion and Interfacial Aspects of Corrosion Protection; and Materials for Corrosion Protection. An extensive subject index is included.

  11. Tensammetric Studies on Corrosion Inhibitors

    Indian Academy of Sciences (India)

    The extent of polarization follows the same order as corrosion inhibition data. Both sodium nitrite and dicyclohexylamine nitrite polarise to the same extent, cyclohexylamine to a lesser extent and morpholine to a still lesser extent. (c) Corrosion inhibition data.-The period for which complete protection is given by the different ...

  12. Agricultural Polymers as Corrosion Inhibitors

    Science.gov (United States)

    Agricultural polymers were composed of extra-cellular polysaccharides secreted by Leuconostoc mesenteroides have been shown to inhibit corrosion on corrosion-sensitive metals. The substantially pure exopolysaccharide has a general structure consisting of alpha(1-6)-linked D-glucose backbone and appr...

  13. Avionics Corrosion Control Study

    Science.gov (United States)

    1974-01-01

    contact with-caustic soda , washing soda , or lime. One of the most har:iiful materials when In contact with aluminum is mercury or any of its salts. Mercury...used with weaker acids such as vinegar . lemon juice, etc. In general, aluminum and its alloys exhibit a wide range of corrosive attack, varying front...SM-43) -(TT-1-7435) 6850-X.13-1544 San-Del #2 Technical Cleaner Baking SoaM. P. Odell Co. Armor (’ 1348) $950-29)2-9611 1169-A Insulating Lacquer Base

  14. Corrosion damage of rivet joints

    Directory of Open Access Journals (Sweden)

    Michal Černý

    2008-01-01

    Full Text Available The work describes the effect of the atmospheric corrosion upon the mechanical properties of blind rivets. The subject of given research is: corrosion of metal materials, system resistance, design modification and others means of prevention against the corrosion attack. The problem of blind rivets, blind rivet setting, setting equipment, terminology and definitions, characteristic, and special blind rivet setting is also analysed. The experiment itself, the experimental method and the evaluation of the test are described. Mechanism of riveted joint damage produced by galvanic corrosion is proposed. Considerable corrosion damage occurred at combination of the joint members and connected materials with different electrochemical potentials. Exposition to the corroding environment produces release of rivet clam, together with decrease of rivet stiffness. The proof of these mechanisms is documented by functional dependence F – ∆L and metallographic tests.

  15. Fatigue and Corrosion in Metals

    CERN Document Server

    Milella, Pietro Paolo

    2013-01-01

    This textbook, suitable for students, researchers and engineers, gathers the experience of more than 20 years of teaching fracture mechanics, fatigue and corrosion to professional engineers and running experimental tests and verifications to solve practical problems in engineering applications. As such, it is a comprehensive blend of fundamental knowledge and technical tools to address the issues of fatigue and corrosion. The book initiates with a systematic description of fatigue from a phenomenological point of view, since the early signs of submicroscopic damage in few surface grains and continues describing, step by step, how these precursors develop to become mechanically small cracks and, eventually, macrocracks whose growth is governed by fracture mechanics. But fracture mechanics is also introduced to analyze stress corrosion and corrosion assisted fatigue in a rather advanced fashion. The author dedicates a particular attention to corrosion starting with an electrochemical treatment that mechanical e...

  16. IN DRIFT CORROSION PRODUCTS

    Energy Technology Data Exchange (ETDEWEB)

    D.M. Jolley

    1999-12-02

    As directed by a written development plan (CRWMS M&O 1999a), a conceptual model for steel and corrosion products in the engineered barrier system (EBS) is to be developed. The purpose of this conceptual model is to assist Performance Assessment Operations (PAO) and its Engineered Barrier Performance Department in modeling the geochemical environment within a repository drift, thus allowing PAO to provide a more detailed and complete in-drift geochemical model abstraction and to answer the key technical issues (KTI) raised in the NRC Issue Resolution Status Report (IRSR) for the Evolution of the Near-Field Environment (NFE) Revision 2 (NRC 1999). This document provides the conceptual framework for the in-drift corrosion products sub-model to be used in subsequent PAO analyses including the EBS physical and chemical model abstraction effort. This model has been developed to serve as a basis for the in-drift geochemical analyses performed by PAO. However, the concepts discussed within this report may also apply to some near and far-field geochemical processes and may have conceptual application within the unsaturated zone (UZ) and saturated zone (SZ) transport modeling efforts.

  17. Corrosion detection of nanowires by magnetic sensors

    KAUST Repository

    Kosel, Jürgen

    2017-10-05

    Disclosed are various embodiments related to a corrosion detection device for detecting corrosive environments. A corrosion detection device comprises a magnetic sensor and at least one magnetic nanowire disposed on the magnetic sensor. The magnetic sensor is configured to detect corrosion of the one or more magnetic nanowires based at least in part on a magnetic field of the one or more magnetic nanowires.

  18. A Multifunctional Coating for Autonomous Corrosion Control

    Science.gov (United States)

    Calle, Luz M.; Li, Wenyan; Buhrow, Jerry W.; Jolley, Scott t.

    2011-01-01

    Nearly all metals and their alloys are subject to corrosion that causes them to lose their structural integrity or other critical functionality. Protective coatings are the most commonly used method of corrosion control. However, progressively stricter environmental regulations have resulted in the ban of many commercially available corrosion protective coatings due to the harmful effects of their solvents or corrosion inhibitors. This work concerns the development of a multifunctional smart coating for the autonomous control of corrosion. This coating is being developed to have the inherent ability to detect the chemical changes associated with the onset of corrosion and respond autonomously to indicate it and control it. The multi-functionality of the coating is based on microencapsulation technology specifically designed for corrosion control applications. This design has, in addition to all the advantages of existing microcapsulation designs, the corrosion controlled release function that triggers the delivery of corrosion indicators and inhibitors on demand, only when and where needed. Microencapsulation of self-healing agents for autonomous repair of mechanical damage to the coating is also being pursued. Corrosion indicators, corrosion inhibitors, as well as self-healing agents, have been encapsulated and dispersed into several paint systems to test the corrosion detection, inhibition, and self-healing properties of the coating. Key words: Corrosion, coating, autonomous corrosion control, corrosion indication, corrosion inhibition, self-healing coating, smart coating, multifunctional coating, microencapsulation.

  19. Recognition and Analysis of Corrosion Failure Mechanisms

    Directory of Open Access Journals (Sweden)

    Steven Suess

    2006-02-01

    Full Text Available Corrosion has a vast impact on the global and domestic economy, and currently incurs losses of nearly $300 billion annually to the U.S. economy alone. Because of the huge impact of corrosion, it is imperative to have a systematic approach to recognizing and mitigating corrosion problems as soon as possible after they become apparent. A proper failure analysis includes collection of pertinent background data and service history, followed by visual inspection, photographic documentation, material evaluation, data review and conclusion procurement. In analyzing corrosion failures, one must recognize the wide range of common corrosion mechanisms. The features of any corrosion failure give strong clues as to the most likely cause of the corrosion. This article details a proven approach to properly determining the root cause of a failure, and includes pictographic illustrations of the most common corrosion mechanisms, including general corrosion, pitting, galvanic corrosion, dealloying, crevice corrosion, microbiologically-influenced corrosion (MIC, corrosion fatigue, stress corrosion cracking (SCC, intergranular corrosion, fretting, erosion corrosion and hydrogen damage.

  20. Some peculiarities of corrosion of wheel steel

    Directory of Open Access Journals (Sweden)

    Alexander SHRAMKO

    2009-01-01

    Full Text Available Corrosion mechanism and rate of different chemical composition and structural condition of wheel steel were investigated. It was shown that “white layers”, variation in grain size and banding of wheel steel structure results in corrosion rate. Microstructure of steel from different elements of railway wheels after operation with corrosion was investigated. Wheel steel with addition of vanadium corroded more quickly than steel without vanadium. Non-metallic inclusions are the centre of corrosion nucleation and their influence on corrosion depends on type of inclusion. Mechanism of corrosion of wheel steel corrosion was discussed.

  1. Corrosion behavior of duplex coatings

    Directory of Open Access Journals (Sweden)

    K. Raghu Ram Mohan Reddy

    2016-07-01

    Full Text Available The titanium alloys are used in defense, aerospace, automobile, chemical plants and biomedical applications due to their very high strength and lightweight properties. However, corrosion is a life-limiting factor when Ti alloys are exposed to different chemical environments at high temperatures. In the present paper, duplex NiCrAlY/WC–Co coating is coated onto Ti6Al4V substrate to investigate the corrosion behavior of both coated samples and the substrate. The duplex coating was performed with NiCrAlY as the intermediate coat of 200 μm thickness deposited by HVOF process and WC–Co ceramic top coat with varying thicknesses of 250 μm, 350 μm and 450 μm deposited by DS process. Potentiodynamic polarization tests were employed to investigate the corrosion performance of duplex coated samples and substrate in Ringer’s solution at 37 °C and pH value was set to 5.7. Finally the results reveal that 350 μm thick coated samples showed highest corrosion resistance compared to 250 μm thick samples as well as bare substrate. However, the 450 μm thick coated sample showed poor corrosion resistance compared to the substrate. The scale formed on the samples upon corrosion was characterized by using SEM analysis to understand the degree of corrosion behavior.

  2. Atmospheric corrosion of mild steel

    Directory of Open Access Journals (Sweden)

    Morcillo, M.

    2011-10-01

    Full Text Available The atmospheric corrosion of mild steel is an extensive topic that has been studied by many authors in different regions throughout the world. This compilation paper incorporates relevant publications on the subject, in particular about the nature of atmospheric corrosion products, mechanisms of atmospheric corrosion and kinetics of the atmospheric corrosion process, paying special attention to two matters upon which relatively less information has been published: a the morphology of steel corrosion products and corrosion product layers; and b long-term atmospheric corrosion ( > 10 years.

    La corrosión atmosférica del acero suave es un tema de gran amplitud que ha sido tratado por muchos autores en numerosas regiones del mundo. Este artículo de compilación incorpora publicaciones relevantes sobre esta temática, en particular sobre la naturaleza de los productos de corrosión atmosférica, mecanismos y cinética de los procesos de corrosión atmosférica, prestando una atención especial a dos aspectos sobre los que la información publicada ha sido menos abundante: a morfología de los productos de corrosión del acero y capas de productos de corrosión, y b corrosión atmosférica a larga duración (> 10 años.

  3. Corrosion protection and control using nanomaterials

    CERN Document Server

    Cook, R

    2012-01-01

    This book covers the use of nanomaterials to prevent corrosion. The first section deals with the fundamentals of corrosion prevention using nanomaterials. Part two includes a series of case studies and applications of nanomaterials for corrosion control.$bCorrosion is an expensive and potentially dangerous problem in many industries. The potential application of different nanostructured materials in corrosion protection, prevention and control is a subject of increasing interest. Corrosion protection and control using nanomaterials explores the potential use of nanotechnology in corrosion control. The book is divided into two parts. Part one looks at the fundamentals of corrosion behaviour and the manufacture of nanocrystalline materials. Chapters discuss the impact of nanotechnology in reducing corrosion cost, and investigate the influence of various factors including thermodynamics, kinetics and grain size on the corrosion behaviour of nanocrystalline materials. There are also chapters on electrodeposition ...

  4. A Theoretical Model for Metal Corrosion Degradation

    OpenAIRE

    David V. Svintradze; Pidaparti, Ramana M.

    2010-01-01

    Many aluminum and stainless steel alloys contain thin oxide layers on the metal surface which greatly reduce the corrosion rate. Pitting corrosion, a result of localized breakdown of such films, results in accelerated dissolution of the underlying metal through pits. Many researchers have studied pitting corrosion for several decades and the exact governing equation for corrosion pit degradation has not been obtained. In this study, the governing equation for corrosion degradation due to pitt...

  5. Model-based prognosis for intergranular corrosion

    OpenAIRE

    Lishchuk, Sergey; Akid, R.; Worden, K.

    2008-01-01

    Among the advantages of Aluminium-based alloys for structural use is their corrosion resistance. However, while Aluminium alloys are highly resistant to uniform (general) corrosion, they are much more susceptible to types of localised corrosion, especially intergranular corrosion, which is a localised attack along the grain boundaries which leaves the grains themselves largely unaffected. In order to estimate the progress of such corrosion in a given sample, it is considered possible to gener...

  6. Cracking and corrosion recovery boiler

    Energy Technology Data Exchange (ETDEWEB)

    Suik, H. [Tallinn Technical University, Horizon Pulp and Paper, Tallinn (Estonia)

    1998-12-31

    The corrosion of heat surfaces and the cracking the drums are the main problems of the recovery boiler. These phenomena have been appeared during long-term operation of boiler `Mitsubishi - 315` erected at 1964. Depth of the crack is depending on the number of shutdowns and on operation time. Corrosion intensity of different heat surfaces is varying depend on the metal temperature and the conditions at place of positioning of tube. The lowest intensity of corrosion is on the bank tubes and the greatest is on the tubes of the second stage superheater and on the tubes at the openings of air ports. (orig.) 5 refs.

  7. Corrosion-resistant coating development

    Energy Technology Data Exchange (ETDEWEB)

    Stinton, D.P.; Kupp, D.M.; Martin, R.L. [Oak Ridge National Lab., TN (United States)

    1997-12-01

    SiC-based heat exchangers have been identified as the prime candidate material for use as heat exchangers in advanced combined cycle power plants. Unfortunately, hot corrosion of the SiC-based materials created by alkali metal salts present in the combustion gases dictates the need for corrosion-resistant coatings. The well-documented corrosion resistance of CS-50 combined with its low (and tailorable) coefficient of thermal expansion and low modulus makes CS-50 an ideal candidate for this application. Coatings produced by gelcasting and traditional particulate processing have been evaluated.

  8. Greener Approach towards Corrosion Inhibition

    Directory of Open Access Journals (Sweden)

    Neha Patni

    2013-01-01

    Full Text Available Corrosion control of metals is technically, economically, environmentally, and aesthetically important. The best option is to use inhibitors for protecting metals and alloys against corrosion. As organic corrosion inhibitors are toxic in nature, so green inhibitors which are biodegradable, without any heavy metals and other toxic compounds, are promoted. Also plant products are inexpensive, renewable, and readily available. Tannins, organic amino acids, alkaloids, and organic dyes of plant origin have good corrosion-inhibiting abilities. Plant extracts contain many organic compounds, having polar atoms such as O, P, S, and N. These are adsorbed on the metal surface by these polar atoms, and protective films are formed, and various adsorption isotherms are obeyed. Various types of green inhibitors and their effect on different metals are mentioned in the paper.

  9. Corrosion resistant neutron absorbing coatings

    Science.gov (United States)

    Choi, Jor-Shan [El Cerrito, CA; Farmer, Joseph C [Tracy, CA; Lee, Chuck K [Hayward, CA; Walker, Jeffrey [Gaithersburg, MD; Russell, Paige [Las Vegas, NV; Kirkwood, Jon [Saint Leonard, MD; Yang, Nancy [Lafayette, CA; Champagne, Victor [Oxford, PA

    2012-05-29

    A method of forming a corrosion resistant neutron absorbing coating comprising the steps of spray or deposition or sputtering or welding processing to form a composite material made of a spray or deposition or sputtering or welding material, and a neutron absorbing material. Also a corrosion resistant neutron absorbing coating comprising a composite material made of a spray or deposition or sputtering or welding material, and a neutron absorbing material.

  10. PAR-1 and PAR-2 Expression Is Enhanced in Inflamed Odontoblast Cells.

    Science.gov (United States)

    Alvarez, M M P; Moura, G E; Machado, M F M; Viana, G M; de Souza Costa, C A; Tjäderhane, L; Nader, H B; Tersariol, I L S; Nascimento, F D

    2017-12-01

    Protease-activated receptors (PARs) are G protein-coupled receptors, which are activated by proteolytical cleavage of the amino-terminus and act as sensors for extracellular proteases. We hypothesized that PAR-1 and PAR-2 can be modulated by inflammatory stimulus in human dental pulp cells. PAR-1 and PAR-2 gene expression in human pulp tissue and MDPC-23 cells were analyzed by quantitative polymerase chain reaction. Monoclonal PAR-1 and PAR-2 antibodies were used to investigate the cellular expression of these receptors using Western blot, flow cytometry, and confocal microscopy in MDPC-23 cells. Immunofluorescence assays of human intact and carious teeth were performed to assess the presence of PAR-1 and PAR-2 in the dentin-pulp complex. The results show for the first time that human odontoblasts and MDPC-23 cells constitutively express PAR-1 and PAR-2. PAR-2 activation increased significantly the messenger RNA expression of matrix metalloproteinase (MMP)-2, MMP-9, MMP-13, and MMP-14 in MDPC-23 cells ( P < 0.05), while the expression of these enzymes decreased significantly in the PAR-1 agonist group ( P < 0.05). The high-performance liquid chromatography and matrix-assisted laser desorption/ionization-time-of-flight mass spectrometry analysis showed the presence of MMP-13 activity cleaving PAR-1 at specific, noncanonical site TLDPRS42↓F43LL in human dental pulp tissues. Also, we detected a presence of a trypsin-like activity cleaving PAR-2 at canonical site SKGR20↓S21LIGRL in pulp tissues. Confocal microscopy analysis of human dentin-pulp complex showed intense positive staining of PAR-1 and PAR-2 in the odontoblast processes in dentinal tubules of carious teeth compared to intact ones. The present results support the hypothesis of activation of the upregulated PAR-1 and PAR-2 by endogenous proteases abundant during the inflammatory response in dentin-pulp complex.

  11. Solutions of corrosion Problems in advanced Technologies

    DEFF Research Database (Denmark)

    Montgomery, Melanie; Karlsson, Asger

    1999-01-01

    Austenitic and ferritic steels were exposed in the superheater area of a straw-fired CHP plant. The specimens were exposed for 1400 hours at 450-600°C. The rate of corrosion was assessed based on unattacked metal remaining. The corrosion products and course of corrosion for the various steel types...... were investigated using light optical and scanning electron microscopy. The ferritic steels suffered from corrosion mainly via material loss. The austenitic steels suffered from predominantly selective corrosion resulting in chromium depletion from the alloy. A clear trend was observed that selective...... corrosion increased with increasing chromium content of the alloy....

  12. A Theoretical Model for Metal Corrosion Degradation

    Directory of Open Access Journals (Sweden)

    David V. Svintradze

    2010-01-01

    Full Text Available Many aluminum and stainless steel alloys contain thin oxide layers on the metal surface which greatly reduce the corrosion rate. Pitting corrosion, a result of localized breakdown of such films, results in accelerated dissolution of the underlying metal through pits. Many researchers have studied pitting corrosion for several decades and the exact governing equation for corrosion pit degradation has not been obtained. In this study, the governing equation for corrosion degradation due to pitting corrosion behavior was derived from solid-state physics and some solutions and simulations are presented and discussed.

  13. Corrosion Inhibition of Stress Corrosion Cracking and Localized Corrosion of Turbo-Expander Materials

    Science.gov (United States)

    Bavarian, Behzad; Zhang, Jia; Reiner, Lisa

    Stress corrosion cracking of 7050 aluminum alloy in the turbo expander and steam/gas turbine industry can cause catastrophic failures, especially for turbo machinery systems performing in hostile, corrosive environments. Commercially available inhibitors were investigated for their effectiveness in reducing and controlling the corrosion susceptibility. Inhibitor effectiveness was confirmed with electrochemical corrosion techniques. Polarization resistance increased with concentration of corrosion inhibitor due to film formation and displacement of water molecules. Cyclic polarization behavior for samples in the 1.0% to 10.0% inhibitor concentration showed a shift in the passive film breakdown potential. The substantial increase in the passive range has positive consequences for neutralizing pitting and crevice corrosion cell chemistry. The strain to failure and tensile strength determined from slow strain rate studies for the aluminum alloy showed pronounced improvement resulting from the inhibitors ability to mitigate SCC. Additionally, the fractographic analysis showed a changed morphology with ductile overload as the primary failure mode instead of transgranular or intergranular cracking.

  14. General Corrosion and Localized Corrosion of the Drip Shield

    Energy Technology Data Exchange (ETDEWEB)

    F. Hua

    2004-09-16

    The repository design includes a drip shield (BSC 2004 [DIRS 168489]) that provides protection for the waste package both as a barrier to seepage water contact and a physical barrier to potential rockfall. The purpose of the process-level models developed in this report is to model dry oxidation, general corrosion, and localized corrosion of the drip shield plate material, which is made of Ti Grade 7. This document is prepared according to ''Technical Work Plan For: Regulatory Integration Modeling and Analysis of the Waste Form and Waste Package'' (BSC 2004 [DIRS 171583]). The models developed in this report are used by the waste package degradation analyses for TSPA-LA and serve as a basis to determine the performance of the drip shield. The drip shield may suffer from other forms of failure such as the hydrogen induced cracking (HIC) or stress corrosion cracking (SCC), or both. Stress corrosion cracking of the drip shield material is discussed in ''Stress Corrosion Cracking of the Drip Shield, the Waste Package Outer Barrier, and the Stainless Steel Structural Material'' (BSC 2004 [DIRS 169985]). Hydrogen induced cracking of the drip shield material is discussed in ''Hydrogen Induced Cracking of Drip Shield'' (BSC 2004 [DIRS 169847]).

  15. Report on accelerated corrosion studies.

    Energy Technology Data Exchange (ETDEWEB)

    Mowry, Curtis Dale; Glass, Sarah Jill; Sorensen, Neil Robert

    2011-03-01

    Sandia National Laboratories (SNL) conducted accelerated atmospheric corrosion testing for the U.S. Consumer Product Safety Commission (CPSC) to help further the understanding of the development of corrosion products on conductor materials in household electrical components exposed to environmental conditions representative of homes constructed with problem drywall. The conditions of the accelerated testing were chosen to produce corrosion product growth that would be consistent with long-term exposure to environments containing humidity and parts per billion (ppb) levels of hydrogen sulfide (H{sub 2}S) that are thought to have been the source of corrosion in electrical components from affected homes. This report documents the test set-up, monitoring of electrical performance of powered electrical components during the exposure, and the materials characterization conducted on wires, screws, and contact plates from selected electrical components. No degradation in electrical performance (measured via voltage drop) was measured during the course of the 8-week exposure, which was approximately equivalent to 40 years of exposure in a light industrial environment. Analyses show that corrosion products consisting of various phases of copper sulfide, copper sulfate, and copper oxide are found on exposed surfaces of the conductor materials including wires, screws, and contact plates. The morphology and the thickness of the corrosion products showed a range of character. In some of the copper wires that were observed, corrosion product had flaked or spalled off the surface, exposing fresh metal to the reaction with the contaminant gasses; however, there was no significant change in the wire cross-sectional area.

  16. Differences in clinical characteristics of fallopian canal dehiscence associated with pars flaccida and pars tensa cholesteatomas.

    Science.gov (United States)

    Shinnabe, Akihiro; Yamamoto, Hiroki; Hara, Mariko; Hasegawa, Masayo; Matsuzawa, Shingo; Kanazawa, Hiromi; Yoshida, Naohiro; Iino, Yukiko

    2014-08-01

    This study investigated the difference in clinical characteristics of fallopian canal dehiscence associated with pars flaccida and pars tensa cholesteatomas for the purpose of increasing the preoperative detectability of dehiscence. A total of 189 ears of patients 7-80 years of age (mean 42 years) with pars flaccida cholesteatoma and 63 ears of patients 9-84 years of age (mean 50 years) with pars tensa cholesteatoma were studied. All patients had undergone prior surgical management at our institution from January 2006 to April 2012. The incidence of fallopian canal dehiscence and its location were compared between pars flaccida and pars tensa cholesteatomas. Intraoperative findings of coexistent pathologies, including destruction of the stapes superstructure, labyrinthine fistula, and dural exposure, were compared between the dehiscence and no-dehiscence groups for the two types of cholesteatomas. The incidence of dehiscence was significantly higher in patients with pars tensa cholesteatoma (55.6 %) than in patients with pars flaccida cholesteatoma (26.5 %). Dehiscence located posterior to the cochleariform process occurred slightly more frequently in patients with pars tensa cholesteatoma than in those with pars flaccida cholesteatoma. In patients with pars flaccida cholesteatoma, labyrinthine fistulas and dural exposure were significantly more frequent in the dehiscence group than in the no-dehiscence group. Fallopian canal dehiscence is more frequent in patients with pars tensa cholesteatoma than in those with pars flaccida cholesteatoma. Especially in patients with pars flaccida cholesteatoma, paying special attention to these coexisting pathologies is important to increase preoperative detectability of dehiscence.

  17. Quantitative measures of corrosion and prevention: application to corrosion in agriculture

    NARCIS (Netherlands)

    Schouten, J.C.; Gellings, P.J.

    1987-01-01

    The corrosion protection factor (c.p.f.) and the corrosion condition (c.c.) are simple instruments for the study and evaluation of the contribution and efficiency of several methods of corrosion prevention and control. The application of c.p.f. and c.c. to corrosion and prevention in agriculture in

  18. Combining hygrothermal and corrosion models to predict corrosion of metal fasteners embedded in wood

    Science.gov (United States)

    Samuel L. Zelinka; Dominique Derome; Samuel V. Glass

    2011-01-01

    A combined heat, moisture, and corrosion model is presented and used to simulate the corrosion of metal fasteners embedded in solid wood exposed to the exterior environment. First, the moisture content and temperature at the wood/fastener interface is determined at each time step. Then, the amount of corrosion is determined spatially using an empirical corrosion rate...

  19. Corrosion effects on friction factors

    Energy Technology Data Exchange (ETDEWEB)

    Magleby, H.L.; Shaffer, S.J.

    1996-03-01

    This paper presents the results of NRC-sponsored material specimen tests that were performed to determine if corrosion increases the friction factors of sliding surfaces of motor-operated gate valves, which could require higher forces to close and open safety-related valves when subjected to their design basis differential pressures. Friction tests were performed with uncorroded specimens and specimens subjected to accelerated corrosion. Preliminary tests at ambient conditions showed that corrosion increased the friction factors, indicating the need for additional tests duplicating valve operating parameters at hot conditions. The additional tests showed friction factors of corroded specimens were 0.1 to 0.2 higher than for uncorroded specimens, and that the friction factors of the corroded specimens were not very dependent on contact stress or corrosion film thickness. The measured values of friction factors for the three corrosion films tested (simulating three operating times) were in the range of 0.3 to 0.4. The friction factor for even the shortest simulated operating time was essentially the same as the others, indicating that the friction factors appear to reach a plateau and that the plateau is reached quickly.

  20. Graphene: corrosion-inhibiting coating.

    Science.gov (United States)

    Prasai, Dhiraj; Tuberquia, Juan Carlos; Harl, Robert R; Jennings, G Kane; Rogers, Bridget R; Bolotin, Kirill I

    2012-02-28

    We report the use of atomically thin layers of graphene as a protective coating that inhibits corrosion of underlying metals. Here, we employ electrochemical methods to study the corrosion inhibition of copper and nickel by either growing graphene on these metals, or by mechanically transferring multilayer graphene onto them. Cyclic voltammetry measurements reveal that the graphene coating effectively suppresses metal oxidation and oxygen reduction. Electrochemical impedance spectroscopy measurements suggest that while graphene itself is not damaged, the metal under it is corroded at cracks in the graphene film. Finally, we use Tafel analysis to quantify the corrosion rates of samples with and without graphene coatings. These results indicate that copper films coated with graphene grown via chemical vapor deposition are corroded 7 times slower in an aerated Na(2)SO(4) solution as compared to the corrosion rate of bare copper. Tafel analysis reveals that nickel with a multilayer graphene film grown on it corrodes 20 times slower while nickel surfaces coated with four layers of mechanically transferred graphene corrode 4 times slower than bare nickel. These findings establish graphene as the thinnest known corrosion-protecting coating.

  1. Microencapsulation of Corrosion Indicators for Smart Coatings

    Science.gov (United States)

    Li, Wenyan; Buhrow, Jerry W.; Jolley, Scott T.; Calle, Luz M.; Hanna,Joshua S.; Rawlins, James W.

    2011-01-01

    A multifunctional smart coating for the autonomous detection, indication, and control of corrosion is been developed based on microencapsulation technology. This paper summarizes the development, optimization, and testing of microcapsules specifically designed for early detection and indication of corrosion when incorporated into a smart coating. Results from experiments designed to test the ability of the microcapsules to detect and indicate corrosion, when blended into several paint systems, show that these experimental coatings generate a color change, indicative of spot specific corrosion events, that can be observed with the naked eye within hours rather than the hundreds of hours or months typical of the standard accelerated corrosion test protocols.. Key words: smart coating, corrosion detection, microencapsulation, microcapsule, pH-sensitive microcapsule, corrosion indicator, corrosion sensing paint

  2. Rail base corrosion and cracking prevention

    Science.gov (United States)

    2014-07-01

    Rail base corrosion combined with fatigue or damage can significantly reduce rail life. Studies were done to examine the relative contribution of damage, corrosion, and fatigue on rail life. The combined effects can be separated into constituent fact...

  3. Corrosion control under thermal insulation and fireproofing

    Energy Technology Data Exchange (ETDEWEB)

    Delahunt, J.F.

    1982-02-01

    Corrosion occurring on carbon steel which is protected by thermal insulation (mineral wool, fiberglass, foam glass, calcium silicate, phenolics, and polyurethanes) or by fireproofing material (concrete or gunite) is discussed. Examples are given and illustrated of corrosion in refineries, petrochemical plants, and pipelines which have been thermally insulated or fireproofed. Four corrosion mechanisms have been identified and are discussed. The promoting action of chlorides as well as the pH effect or corrosion are described and it is concluded that the corrosion under thermal insulation follows two patterns. Further, organic cellular foams (polyurethanes and phenolics) are shown to accelerate corrosive action. Stress corrosion cracking of stainless steel under thermal insulation is described and the effect of improper design/application is stressed. Specific measures to control corrosion are discussed for concrete fireproofing and thermal insulation. (MJJ)

  4. Cracking of SHCC due to reinforcement corrosion

    NARCIS (Netherlands)

    Savija, B.; Lukovic, M.; Pacheco Farias, J.; Schlangen, H.E.J.G.; Saouma, V.; Bolander, J.; Landis, E.

    2016-01-01

    Reinforcement corrosion is the most important deterioration mechanism affecting reinforced concrete infrastructures. After corrosion starts, expansive pressures are exerted onto the surrounding concrete, causing cracking and spalling of the cover concrete. The amount of cover cracking can possibly

  5. Inhibition of corrosion of copper in nitric acid solution by some arylmethylene cyanothioacetamide derivatives

    Science.gov (United States)

    Fouda, A. S.; Mohamed, A. K.; Mostafa, H. A.

    1998-01-01

    The inhibition of corrosion of copper in 2M HNO3 solution by some arylmethylene cyanothioacetamide derivatives was tested using polarization measurements. The results showed that these compounds act as mixed type inhibitors and inhibition efficiencies up to 90% can be obtained. The inhibition was assumed to occur via physical adsorption of the inhibitor molecules fitting a Frumkin isotherm. The influence of the substituent group on the inhibition efficiency of the inhibitor was explained in terms of the density of the electron cloud on the cyanothioacetamide moiety and the mode of adsorption. The increase in temperature was found to increase the corrosion in absence and in presence of inhibitors. Some thermodynamic functions were also computed and discussed. L'inhibition de la corrosion du cuivre dans des solutions 2M HNO3 par quelques dérivés d'arylméthylène cyanothioacétamides a été testée par des mesures de polarisation. Les résultats montrent que ces composés se comportent comme des inhibiteurs mixtes. Des efficacités d'inhibition jusqu'à 90 % peuvent être obtenues. L'inhibition est supposée se produire par l'adsorption des molécules d'inhibiteur suivant une isotherme de Frumkin. L'influence de groupe substituant sur l'efficacité de l'inhibiteur a été interprétée en terme de densité du nuage électronique sur la partie cyanothioacétamide et de mode d'adsorption. L'augmentation de la température augmente la corrosion en l'absence et en présence d'inhibiteur. Certaines fonctions thermodynamiques ont également été calculées et discutées.

  6. Echangeurs à condensation sur fumées corrosives Condensation Heat Exchangers of Corrosive Fumes

    Directory of Open Access Journals (Sweden)

    Grehier A.

    2006-11-01

    Full Text Available Les échangeurs gaz-liquide et gaz-gaz respectivement développés par la Société Nationale Elf Aquitaine (SNEA et l'institut Français du Pétrole (IFP dans le cadre d'un contrat AFME d'aide à l'innovation permettent, grâce au recours à des matériaux plastiques, de s'affranchir du seuil de condensation sulfurique, 180°C, en deçà duquel apparaissent les problèmes de corrosion sur les récupérateurs classiques. Il en résulte un accroissement de chaleurs sensible et latente récupérées permettant, en moyenne, de doubler l'économie habituellement réalisée. Ces travaux ont démontré la faisabilité technique des solutions proposées dont la pénétration sur le marché doit être favorisée par leur faible coût d'insertion dans les installations existantes et leur temps de retour voisin de 2 ans. The gas-liquid and gas-gas heat exchangers developed respectively by the Société Nationale Elf Aquitaine (SNEA and the Institut Français du Pétrole (IFP, within the framework of an AFME contract to promote innovation, make use of plastics to overcome the sulfuric condensation threshold of 180°C. Beyond this threshold, corrosion problems appear for conventional heat recovery processes. This results in an increase in the recovery of sensible and latent heat, so that the saving normally achieved can be doubled, on the average. This research has shown the technical feasibility of the solution proposed. The market penetration of these solutions should be enhanced by their low cost of insertion in existing installations and their payout time of about two years.

  7. Smart Coatings for Launch Site Corrosion Protection

    Science.gov (United States)

    Calle, Luz M.

    2014-01-01

    Smart, environmentally friendly paint system for early corrosion detection, mitigation, and healing that will enable supportability in KSC launch facilities and ground systems through their operational life cycles. KSC's Corrosion Technology Laboratory is developing a smart, self-healing coating that can detect and repair corrosion at an early stage. This coating is being developed using microcapsules specifically designed to deliver the contents of their core when corrosion starts.

  8. Corrosion of metals by hydrazine

    Science.gov (United States)

    Lawton, E. A.; Moran, C. M.; Distefano, S.

    1985-01-01

    The mechanism of corrosion of metals by hydrazine has been studied by means of coupons in sealed ampoules and by electrochemical techniques. The variables considered were temperature, CO2 impurity level, alloy composition and microcrystalline structure. The coupon studies, to date, verify that increasng temperature and the presence of CO2 does increase the corrosion rate as expected. The presence of molybdenum in stainless steels to the 3 percent level is not necessarily deleterious, contrary to published reports. The influence of microcrystalline structure and surface characteristics are more dominant effects. However, with Ti-6Al-4V, two different microcrystalline structures showed no significant differences. Corrosion rates of CRES 304 L in hydrazine have also been measured by several electrochemical techniques such as Tafel plots, polarization resistance and A. C. Impedance. This is the first documented work to show that A. C. Impedance can be used with non-aqueous solvents. Preliminary data correlated satisfactorily with the results of the coupon studies.

  9. Corrosion inhibitor testing in archaeological conservation

    Directory of Open Access Journals (Sweden)

    Robert Faltermeier

    1997-11-01

    Full Text Available Metal objects from archaeological contexts often suffer serious damage by corrosion. Various methods for inhibiting corrosion have been developed, but their effects need to be evaluated. Here new research is described on how treatments to inhibit the corrosion of copper and copper-alloy artefacts may be tested.

  10. A Multifunctional Coating for Autonomous Corrosion Control

    Science.gov (United States)

    Calle, Luz M.; Hintze, Paul E.; Li, Wenyan; Buhrow, Jerry W.; Jolley, Scott T.

    2010-01-01

    Corrosion is a destructive process that often causes failure in metallic components and structures. Protective coatings are the most commonly used method of corrosion control. However, progressively stricter environmental regulations have resulted in the ban of many commercially available corrosion protective coatings due to the harmful effects of their solvents or corrosion inhibitors. This work concerns the development of a multifunctional, smart coating for the autonomous control of corrosion. This coating is being developed to have the inherent ability to detect the chemical changes associated with the onset of corrosion and respond autonomously to control it. The multi-functionality of the coating is based on microencapsulation technology specifically designed for corrosion control applications. This design has, in addition to all the advantages of other existing microcapsules designs, the corrosion controlled release function that allows the delivery of corrosion indicators and inhibitors on demand only when and where they are needed. Corrosion indicators as well as corrosion inhibitors have been incorporated into the microcapsules, blended into several paint systems, and tested for corrosion detection and protection efficacy.

  11. Corrosion and chemical resistant masonry materials handbook

    National Research Council Canada - National Science Library

    Sheppard, Walter Lee

    1986-01-01

    ... and other equipment. But few other than chemists and chemical engineers identify "corrosion" as chemical degradation or destruction of a material, and therefore, something that can happen to nonmetals (concrete, plastics, brick, timber, etc.) as well as to nletals. The National Association of Corrosion Engineers so defined "corrosion" over thirty years ago but this f...

  12. 49 CFR 193.2625 - Corrosion protection.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Corrosion protection. 193.2625 Section 193.2625...: FEDERAL SAFETY STANDARDS Maintenance § 193.2625 Corrosion protection. (a) Each operator shall determine which metallic components could, unless corrosion is controlled, have their integrity or reliability...

  13. Fastener corrosion : testing, research, and design considerations

    Science.gov (United States)

    Douglas R. Rammer; Samuel L. Zelinka; Philip Line

    2006-01-01

    In 2004, the voluntary removal of chromated copper arsenate (CCA) from residential wood construction raised concern about corrosion of metal fasteners in wood treated with replacement preservatives. Replacement preservatives contain more copper, which may increase corrosion, and do not contain chromates or arsenates, which are known corrosion inhibitors. This paper is...

  14. 7 CFR 2902.44 - Corrosion preventatives.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 15 2010-01-01 2010-01-01 false Corrosion preventatives. 2902.44 Section 2902.44... Items § 2902.44 Corrosion preventatives. (a) Definition. Products designed to prevent the deterioration (corrosion) of metals. (b) Minimum biobased content. The preferred procurement product must have a minimum...

  15. Corrosion-Inhibitor Efficiency Control: Comparison by Means of Different Portable Corrosion Rate Meters

    OpenAIRE

    Martinez Sierra, Isabel; Andrade Perdrix, Maria del Carmen; Rebolledo Ramos, Nuria; Luo, L.; De Schutter, G.

    2010-01-01

    Corrosion-inhibiting substances have been applied to suppress corrosion mainly on bare steel, but when corrosion is progressing, suppression can be achieved if anodic and cathodic reactions are avoided, which is not an easy objective, particularly if the bare metal is surrounded by concrete. In the present article, several corrosion inhibitors are studied to identify their inhibition efficiency in concrete. The percentage of reduction of the corrosion rate without and with inhibitor is named ...

  16. Electrochemical Studies of Atmospheric Corrosion.

    Science.gov (United States)

    1979-01-01

    1 A 0 A063 922 ROCKwELL INTERNATIONAL THOUSAND OAKS CALIF SCIENCE ——ETC F/S 11/6 ELECTROC HEMICAL STUDIES OF ATMOSPHERIC CORROSION. (U) JAN 19 F S...reduction increased linearly with inverse film thickness. Similar experiments in wh i ch corrosion kinetics were determined DO JAN ~~ 1473 EDITION OF I...the ACM and In the design for two- and three-electrode systems . The basic principle of the ACM was first discussed by Tomashov (S)1 and Kucera and

  17. Corrosion Reliability of Electronic Systems

    DEFF Research Database (Denmark)

    Ambat, Rajan; Jensen, Stine G.; Møller, Per

    2008-01-01

    Inherently two factors namely multi-material usage and potential bias makes electronic devices susceptible to corrosion if exposed to humid conditions. The problem is compounded today due to miniaturization and contamination effects. The reduction in size of the components and close spacing...... on a Printed Circuit Board (PCB) for high density packing has greatly increased the risk of corrosion under humid conditions. An important issue is the failures due to electrolytic metal migration. This paper describes an investigation of the electrolytic migration of Sn-Pb solder lines on PCBs in humid...

  18. High temperature corrosion in gasifiers

    Directory of Open Access Journals (Sweden)

    Wate Bakker

    2004-03-01

    Full Text Available Several commercial scale coal gasification combined cycle power plants have been built and successfully operated during the last 5-10 years. Supporting research on materials of construction has been carried out for the last 20 years by EPRI and others. Emphasis was on metallic alloys for heat exchangers and other components in contact with hot corrosive gases at high temperatures. In this paper major high temperature corrosion mechanisms, materials performance in presently operating gasifiers and future research needs will be discussed.

  19. A Multifunctional Coating for Autonomous Corrosion Control

    Science.gov (United States)

    Calle, L. M.; Hintze, P. E.; Li, W.; Buhrow, J. W.; Jolley, S. T.

    2011-01-01

    This slide presentation reviews the effects of corrosion on various structures at the Kennedy Space Center, and the work to discover a corrosion control coating that will be autonomous and will indicate corrosion at an early point in the process. Kennedy Space Center has many environmental conditions that are corrosive: ocean salt spray, heat, humidity, sunlight and acidic exhaust from the Solid Rocket Boosters (SRBs). Presented is a chart which shows the corrosion rates of carbon steel at various locations. KSC has the highest corrosion rates with 42.0 mils/yr, leading the next highest Galeta Point Beach, in the Panama Canal Zone with 27 mils/yr corrosion. A chart shows the changes in corrosion rate with the distance from the ocean. The three types of corrosion protective coatings are described: barrier (passive), Barrier plus active corrosion inhibiting components, and smart. A smart coating will detect and respond actively to changes in its environment in a functional and predictable manner and is capable of adapting its properties dynamically. The smart coating uses microcapsules, particles or liquid drops coated in polymers, that can detect and control the corrosion caused by the environment. The mechanism for a pH sensitive microcapsule and the hydrophobic core microcapsule are demonstrated and the chemistry is reviewed. When corrosion begins, the microcapsule will release the contents of the core (indicator, inhibitor, and self healing agent) in close proximity to the corrosion. The response to a pH increase is demonstrated by a series of pictures that show the breakdown of the microcapsule and the contents release. An example of bolt corrosion is used, as an example of corrosion in places that are difficult to ascertain. A comparison of various coating systems is shown.

  20. 219-S CORROSION STUDY

    Energy Technology Data Exchange (ETDEWEB)

    DIVINE JR; PARSONS GL

    2008-12-01

    A minor leak was detected in a drain line for Hood 2B located in the 222-S Laboratory. The line transfers radioactive waste, spent analytical standards, and chemicals used in various analytical procedures. Details are in the report provided by David Comstock, 2B NDE June 2008, work package LAB-WO-07-2012. Including the noted leak, the 222-S Laboratory has experienced two drain line leaks in approximately the last two years of operation. As a consequence, CH2M HILL Hanford Group, Inc. (CH2M HILL) requested the support of ChemMet, Ltd., PC (ChemMet) at the Hanford Site 222-S Laboratory. The corrosion expertise from ChemMet was required prior to preparation of a compatibility assessment for the 222-S Laboratory waste transfer system to assure the expected life of the piping system is extended as much as practicable. The system includes piping within the 222-S Laboratory and the 219-S Waste Storage and Transfer Facility and Operations Process. The ChemMet support was required for an assessment by 222-S staff to analyze what improvements to operational activities may be implemented to extend the tank/piping system life. This assessment will include a summary of the various material types, age, and locations throughout the facility. The assessment will also include a discussion of materials that are safe for drain line disposal on a regular basis, materials that are safe for disposal on a case-by-case basis including specific additional requirements such as flushing, neutralization to a specific pH, and materials prohibited from disposal. The assessment shall include adequate information for 222-S Laboratory personnel to make informed decisions in the future disposal of specific material types by discussing types of compatibility of system materials and potential wastes. The assessment is expected to contain some listing of acceptable waste materials but is not anticipated to be a complete or comprehensive list. Finally the assessment will encompass a brief discussion of

  1. Assessing Level and Effectiveness of Corrosion Education in the UAE

    Directory of Open Access Journals (Sweden)

    Hwee Ling Lim

    2012-01-01

    Full Text Available The consequences of corrosion can be minimized by an engineering workforce well trained in corrosion fundamentals and management. Since the United Arab Emirates incurs the second highest cost of corrosion after Saudi Arabia, this paper examined the quality of corrosion education in the UAE. Surveys with academia and industry respondents showed that dedicated corrosion courses and engineering courses that integrated corrosion into the curricula were available in UAE universities, but graduates had insufficient knowledge of corrosion engineering and superficial understanding of corrosion in real-life design contexts. The effectiveness of corrosion education is determined by both competence in corrosion knowledge/skills and availability of resources (faculty and research. Though most departments would not hire new corrosion-specialist faculty, department research efforts and industry partnerships in corrosion research were present. The paper concluded with recommendations for improving knowledge and skills of future engineers in corrosion and enhancing corrosion instruction to better meet industry needs.

  2. General Corrosion and Localized Corrosion of Waste Package Outer Barrier

    Energy Technology Data Exchange (ETDEWEB)

    Farmer, J.C.; McCright, R.D.

    2000-01-28

    Alloy 22 is an extremely Corrosion Resistant Material, with a very stable passive film. Based upon exposures in the LTCTF, the GC rates of Alloy 22 are typically below the level of detection, with four outliers having reported rates up to 0.75 #mu#m per year. In any event, over the 10,000 year life of the repository, GC of the Alloy 22 (assumed to be 2 cm thick) should not be life limiting. Because measured corrosion potentials are far below threshold potentials, localized breakdown of the passive film is unlikely under plausible conditions, even in SSW at 120 deg C. The pH in ambient-temperature crevices formed from Alloy 22 have been determined experimentally, with only modest lowering of the crevice pH observed under plausible conditions. Extreme lowering of the crevice pH was only observed under situations where the applied potential at the crevice mouth was sufficient to result in catastrophic breakdown of the passive film above the threshold potential in non-buffered conditions not characteristic of the Yucca Mountain environment. In cases where naturally ocurring buffers are present in the crevice solution, little or no lowering of the pH was observed, even with significant applied potential. With exposures of twelve months, no evidence of crevice corrosion has been observed in SDW, SCW and SAW at temperatures up to 90 deg C. An abstracted model has been presented, with parameters determined experimentally, that should enable performance assessment to account for the general and localized corrosion of this material. A feature of this model is the use of the materials specification to limit the range of corrosion and threshold potentials, thereby making sure that substandard materials prone to localized attack are avoided. Model validation will be covered in part by a companion SMR on abstraction of this model.

  3. Nodular Corrosion Characteristics of Zirconium Alloys

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Gil; Jeong, Y. H.; Park, S. Y.; Lee, D. J

    2003-01-15

    This study was reported the effect of the nodular corrosion on the nuclear reactor environmental along with metallurgical influence, also suggested experimental scheme related to evaluate nodular corrosion characteristics of Zr-1 Nb alloy. Remedial strategies against the nodular corrosion should firstly develop plan to assess the effect of the water quality condition (Oxygen, Hydrogen) as well as the boiling on the nodular corrosion, secondarily establish plan to control heat treatment process to keep a good resistance on nodular corrosion in Zr-1Nb alloy as former western reactor did.

  4. Corrosion of Metal-Matrix Composites with Aluminium Alloy Substrate

    Directory of Open Access Journals (Sweden)

    B. Bobic

    2010-03-01

    Full Text Available The corrosion behaviour of MMCs with aluminium alloy matrix was presented. The corrosion characteristics of boron-, graphite-, silicon carbide-, alumina- and mica- reinforced aluminium MMCs were reviewed. The reinforcing phase influence on MMCs corrosion rate as well as on various corrosion forms (galvanic, pitting, stress corrosion cracking, corrosion fatique, tribocorrosion was discussed. Some corrosion protection methods of aluminium based MMCs were described

  5. The dual role of microbes in corrosion

    Science.gov (United States)

    Kip, Nardy; van Veen, Johannes A

    2015-01-01

    Corrosion is the result of a series of chemical, physical and (micro) biological processes leading to the deterioration of materials such as steel and stone. It is a world-wide problem with great societal and economic consequences. Current corrosion control strategies based on chemically produced products are under increasing pressure of stringent environmental regulations. Furthermore, they are rather inefficient. Therefore, there is an urgent need for environmentally friendly and sustainable corrosion control strategies. The mechanisms of microbially influenced corrosion and microbially influenced corrosion inhibition are not completely understood, because they cannot be linked to a single biochemical reaction or specific microbial species or groups. Corrosion is influenced by the complex processes of different microorganisms performing different electrochemical reactions and secreting proteins and metabolites that can have secondary effects. Information on the identity and role of microbial communities that are related to corrosion and corrosion inhibition in different materials and in different environments is scarce. As some microorganisms are able to both cause and inhibit corrosion, we pay particular interest to their potential role as corrosion-controlling agents. We show interesting interfaces in which scientists from different disciplines such as microbiology, engineering and art conservation can collaborate to find solutions to the problems caused by corrosion. PMID:25259571

  6. CORROSION RESISTANT JACKETED METAL BODY

    Science.gov (United States)

    Brugmann, E.W.

    1958-08-26

    Reactor faul elements of the elongated cylindrical type which are jacketed in a corrosion resistant material are described. Each feel element is comprised of a plurality of jacketed cylinders of fissionable material in end to end abutting relationship, the jackets being welded together at their adjoining ends to retain the individual segments together and seat the interior of the jackets.

  7. Hot Corrosion in Gas Turbines.

    Science.gov (United States)

    1983-04-27

    in hot corrosion under some circumstances, because its role seems to be principally through reduction of NagSO, or erosion by pyrolytic graphite...same morphology could be produced either by spray -coating with NaxSO, or by diffusing NIS into the cut- edge region under argon at temperature and then

  8. Hydrogen effects in corrosion: discussion

    Science.gov (United States)

    Stopher, Miles A.; Simpson, E. Luke

    2017-06-01

    This session contained talks on the characterization of hydrogen-enhanced corrosion of steels and nickel-based alloys, emphasizing the different observations across length scales, from atomic-scale spectrographic to macro-scale fractographic examinations. This article is part of the themed issue 'The challenges of hydrogen and metals'.

  9. Evolutionary Computation Techniques for Predicting Atmospheric Corrosion

    Directory of Open Access Journals (Sweden)

    Amine Marref

    2013-01-01

    Full Text Available Corrosion occurs in many engineering structures such as bridges, pipelines, and refineries and leads to the destruction of materials in a gradual manner and thus shortening their lifespan. It is therefore crucial to assess the structural integrity of engineering structures which are approaching or exceeding their designed lifespan in order to ensure their correct functioning, for example, carrying ability and safety. An understanding of corrosion and an ability to predict corrosion rate of a material in a particular environment plays a vital role in evaluating the residual life of the material. In this paper we investigate the use of genetic programming and genetic algorithms in the derivation of corrosion-rate expressions for steel and zinc. Genetic programming is used to automatically evolve corrosion-rate expressions while a genetic algorithm is used to evolve the parameters of an already engineered corrosion-rate expression. We show that both evolutionary techniques yield corrosion-rate expressions that have good accuracy.

  10. Predicting the Performance of Organic Corrosion Inhibitors

    Directory of Open Access Journals (Sweden)

    David A. Winkler

    2017-12-01

    Full Text Available The withdrawal of effective but toxic corrosion inhibitors has provided an impetus for the discovery of new, benign organic compounds to fill that role. Concurrently, developments in the high-throughput synthesis of organic compounds, the establishment of large libraries of available chemicals, accelerated corrosion inhibition testing technologies, and the increased capability of machine learning methods have made discovery of new corrosion inhibitors much faster and cheaper than it used to be. We summarize these technical developments in the corrosion inhibition field and describe how data-driven machine learning methods can generate models linking molecular properties to corrosion inhibition that can be used to predict the performance of materials not yet synthesized or tested. We briefly summarize the literature on quantitative structure–property relationships models of small organic molecule corrosion inhibitors. The success of these models provides a paradigm for rapid discovery of novel, effective corrosion inhibitors for a range of metals and alloys in diverse environments.

  11. High Temperature Corrosion on Biodust Firing

    DEFF Research Database (Denmark)

    Okoro, Sunday Chukwudi

    The high content of alkali metals and chlorine in biomass gives rise to fouling/slagging and corrosion of heat exchange components, such as superheaters, in biomass fired power plants. Increasing the lifetime of these components, and in addition, preventing unwarranted plant shutdowns due...... to their failure, requires understanding of the complex corrosion mechanisms, as well as development of materials that are resistant to corrosion under biomass firing conditions, thereby motivating the current work. To understand the mechanisms of corrosion attack, comprehensive analysis of corrosion products...... was necessary. In the present work, two complementary methodologies based on analysis of cross sections and plan views were applied to achieve comprehensive characterization of corrosion products. The suitability of these methods for both laboratory scale and full scale corrosion investigations was demonstrated...

  12. Corrosion Control in the Aerospace Industry

    Science.gov (United States)

    Calle, Luz Marina; Li, Wenyan; Buhrow, Jerry W.; Johnsey, Marissa N.

    2016-01-01

    Nearly all metals and their alloys are subject to corrosion that causes them to lose their structural integrity or other critical functionality. It is essential to detect corrosion when it occurs, and preferably at its early stage, so that action can be taken to avoid structural damage or loss of function. Protective coatings are the most commonly used method of corrosion control. However, progressively stricter environmental regulations have resulted in the ban of many commercially available corrosion protective coatings due to the harmful effects of their solvents or corrosion inhibitors. This work concerns the development of a multifunctional, smart coating for the autonomous control of corrosion. This coating is being developed to have the inherent ability to detect the chemical changes associated with the onset of corrosion and respond autonomously to indicate it and control it..

  13. Corrosion Rate Monitoring in District Heating Systems

    DEFF Research Database (Denmark)

    Hilbert, Lisbeth Rischel; Nielsen, Lars Vendelbo; Andersen, A.

    2005-01-01

    Quality control in district heating systems to keep uniform corrosion rates low and localized corrosion minimal is based on water quality control. Side-stream units equipped with carbon steel probes for online monitoring were mounted in district heating plants to investigate which techniques would...... be applicable, and if on-line monitoring could improve the quality control. Water quality monitoring was applied as well as corrosion rate monitoring with linear polarization resistance (LPR), electrochemical impedance spectroscopy (EIS), electrical resistance (ER) technique, mass loss and a crevice corrosion...... cell for localized corrosion risk estimation. Important variations in corrosion rate due to changes in make-up water quality were detected with the continuous monitoring provided by ER and crevice cell, while LPR gave unreliable corrosion rates. The acquisition time of two-three days for EIS...

  14. Corrosion mechanism applicable to biodegradable magnesium implants

    Energy Technology Data Exchange (ETDEWEB)

    Atrens, Andrej, E-mail: Andrejs.Atrens@uq.edu.au [University of Queensland, Division of Materials, Brisbane, Qld 4072 (Australia); Liu Ming; Zainal Abidin, Nor Ishida [University of Queensland, Division of Materials, Brisbane, Qld 4072 (Australia)

    2011-12-15

    Much of our understanding of the Mg corrosion mechanism is based on research using aggressive chloride based solutions like 3% NaCl, which are appropriate for understand the corrosion for applications such as auto construction. The chloride ions tend to cause break down of the partly protective surface film on the Mg alloy surface. The corrosion rate increases with exposure time until steady state is reached, which may take several weeks. An overview is provided of the aspects which determine the corrosion of Mg alloys: (i) measurement details; (ii) impurity elements Fe, Ni, Cu and Co; (iii) second phases; (iv) surface films and surface condition and (v) stress corrosion cracking (SCC). This understanding is used to help understand Mg corrosion for Mg as a biodegradable implant for medical applications. Solutions that elucidate these applications tend to form surface films and the corrosion rate tends to decrease with immersion time.

  15. NASA's Corrosion Technology Laboratory at the Kennedy Space Center: Anticipating, Managing, and Preventing Corrosion

    Science.gov (United States)

    Calle, Luz Marina

    2015-01-01

    The marine environment at NASAs Kennedy Space Center (KSC) has been documented by ASM International (formerly American Society for Metals) as the most corrosive in North America. With the introduction of the Space Shuttle in 1981, the already highly corrosive conditions at the launch pads were rendered even more severe by the highly corrosive hydrochloric acid (HCl) generated by the solid rocket boosters (SRBs). Numerous failures at the launch pads are caused by corrosion. The structural integrity of ground infrastructure and flight hardware is critical to the success, safety, cost, and sustainability of space missions. NASA has over fifty years of experience dealing with unexpected failures caused by corrosion and has developed expertise in corrosion control in the launch and other environments. The Corrosion Technology Laboratory at KSC evolved, from what started as an atmospheric exposure test site near NASAs launch pads, into a capability that provides technical innovations and engineering services in all areas of corrosion for NASA, external partners, and customers.This paper provides a chronological overview of NASAs role in anticipating, managing, and preventing corrosion in highly corrosive environments. One important challenge in managing and preventing corrosion involves the detrimental impact on humans and the environment of what have been very effective corrosion control strategies. This challenge has motivated the development of new corrosion control technologies that are more effective and environmentally friendly. Strategies for improved corrosion protection and durability can have a huge impact on the economic sustainability of human spaceflight operations.

  16. The ParB-parS Chromosome Segregation System Modulates Competence Development in Streptococcus pneumoniae.

    Science.gov (United States)

    Attaiech, Laetitia; Minnen, Anita; Kjos, Morten; Gruber, Stephan; Veening, Jan-Willem

    2015-06-30

    ParB proteins bind centromere-like DNA sequences called parS sites and are involved in plasmid and chromosome segregation in bacteria. We previously showed that the opportunistic human pathogen Streptococcus pneumoniae contains four parS sequences located close to the origin of replication which are bound by ParB. Using chromatin immunoprecipitation (ChIP), we found here that ParB spreads out from one of these parS sites, parS(-1.6°), for more than 5 kb and occupies the nearby comCDE operon, which drives competence development. Competence allows S. pneumoniae to take up DNA from its environment, thereby mediating horizontal gene transfer, and is also employed as a general stress response. Mutating parS(-1.6°) or deleting parB resulted in transcriptional up-regulation of comCDE and ssbB (a gene belonging to the competence regulon), demonstrating that ParB acts as a repressor of competence. However, genome-wide transcription analysis showed that ParB is not a global transcriptional regulator. Different factors, such as the composition of the growth medium and antibiotic-induced stress, can trigger the sensitive switch driving competence. This work shows that the ParB-parS chromosome segregation machinery also influences this developmental process. Streptococcus pneumoniae (pneumococcus) is an important human pathogen responsible for more than a million deaths each year. Like all other organisms, S. pneumoniae must be able to segregate its chromosomes properly. Not only is understanding the molecular mechanisms underlying chromosome segregation in S. pneumoniae therefore of fundamental importance, but also, this knowledge might offer new leads for ways to target this pathogen. Here, we identified a link between the pneumococcal chromosome segregation system and the competence-developmental system. Competence allows S. pneumoniae to take up and integrate exogenous DNA in its chromosome. This process plays a crucial role in successful adaptation to--and escape from

  17. Corrosion Cost and Corrosion Map of Korea - Based on the Data from 2005 to 2010

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Y. S.; Lim, H. K. [Andong National University, Andong (Korea, Republic of); Kim, J. J. [Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of); Hwang, W. S. [Inha University, Incheon (Korea, Republic of); Park, Y. S. [Yonsei University, Seoul (Korea, Republic of)

    2011-04-15

    Corrosion of metallic materials occurs by the reaction with corrosive environment such as atmosphere, marine, soil, urban, high temperature etc. In general, reduction of thickness and cracking and degradation are resulted from corrosion. Corrosion in all industrial facilities and infrastructure causes large economic losses as well as a large number of accidents. Economic loss by corrosion has been reported to be nearly 1-6% of GNP or GDP. In order to reduce corrosion damage of industrial facilities, corrosion map as well as a systematic investigation of the loss of corrosion in each industrial sector is needed. The Corrosion Science Society of Korea in collaboration with 15 universities and institutes has started to survey on the cost of corrosion and corrosion map of Korea since 2005. This work presents the results of the survey on cost of corrosion by Uhlig, Hoar, and input-output methods, and the evaluation of atmospheric corrosion rate of carbon steel, weathering steel, galvanized steel, copper, and aluminum in Korea. The total corrosion cost was estimated in terms of the percentage of the GDP of industry sectors and the total GDP of Korea. According to the result of Input/output method, corrosion cost of Korea was calculated as 2.9% to GDP (2005). Time of wetness was shown to be categories 3 to 4 in all exposure areas. A definite seasonal difference was observed in Korea. In summer and fall, time of wetness was higher than in other seasons. Because of short exposure period (12 months), significant corrosion trends depending upon materials and exposure corrosion environments were not revealed even though increased mass loss and decreased corrosion rate by exposure time.

  18. ParAB Partition Dynamics in Firmicutes: Nucleoid Bound ParA Captures and Tethers ParB-Plasmid Complexes.

    Directory of Open Access Journals (Sweden)

    Virginia S Lioy

    Full Text Available In Firmicutes, small homodimeric ParA-like (δ2 and ParB-like (ω2 proteins, in concert with cis-acting plasmid-borne parS and the host chromosome, secure stable plasmid inheritance in a growing bacterial population. This study shows that (ω:YFP2 binding to parS facilitates plasmid clustering in the cytosol. (δ:GFP2 requires ATP binding but not hydrolysis to localize onto the cell's nucleoid as a fluorescent cloud. The interaction of (δ:CFP2 or δ2 bound to the nucleoid with (ω:YFP2 foci facilitates plasmid capture, from a very broad distribution, towards the nucleoid and plasmid pairing. parS-bound ω2 promotes redistribution of (δ:GFP2, leading to the dynamic release of (δ:GFP2 from the nucleoid, in a process favored by ATP hydrolysis and protein-protein interaction. (δD60A:GFP2, which binds but cannot hydrolyze ATP, also forms unstable complexes on the nucleoid. In the presence of ω2, (δD60A:GFP2 accumulates foci or patched structures on the nucleoid. We propose that (δ:GFP2 binding to different nucleoid regions and to ω2-parS might generate (δ:GFP2 gradients that could direct plasmid movement. The iterative pairing and unpairing cycles may tether plasmids equidistantly on the nucleoid to ensure faithful plasmid segregation by a mechanism compatible with the diffusion-ratchet mechanism as proposed from in vitro reconstituted systems.

  19. Microencapsulation Technology for Corrosion Mitigation by Smart Coatings

    Science.gov (United States)

    Buhrow, Jerry; Li, Wenyan; Jolley, Scott; Calle, Luz M.

    2011-01-01

    A multifunctional, smart coating for the autonomous control of corrosion is being developed based on micro-encapsulation technology. Corrosion indicators as well as corrosion inhibitors have been incorporated into microcapsules, blended into several paint systems, and tested for corrosion detection and protection effectiveness. This paper summarizes the development, optimization, and testing of microcapsules specifically designed to be incorporated into a smart coating that will deliver corrosion inhibitors to mitigate corrosion autonomously. Key words: smart coating, corrosion inhibition, microencapsulation, microcapsule, pH sensitive microcapsule, corrosion inhibitor, corrosion protection pain

  20. Electrochemical study on metal corrosion in chemical mechanical planarization process

    Science.gov (United States)

    Kondo, Seiichi; Ichige, Yasuhiro; Otsuka, Yuya

    2017-07-01

    Typical metal corrosions caused by the chemical mechanical planarization (CMP) process are discussed in this review paper. By categorizing them into seven kinds of corrosion, namely, chemical corrosion, crevice corrosion, crystal-orientation-dependent corrosion, narrow trench corrosion, photocorrosion, galvanic corrosion, and electrostatic-charge induced corrosion, we discuss their mechanisms and how to suppress them on the basis of electrochemical studies. Moreover, we demonstrate the usefulness of three-dimensional pH-potential diagrams for predicting corrosion issues in an actual CMP process.

  1. Corrosion Product Film-Induced Stress Facilitates Stress Corrosion Cracking.

    Science.gov (United States)

    Wang, Wenwen; Zhang, Zhiliang; Ren, Xuechong; Guan, Yongjun; Su, Yanjing

    2015-06-11

    Finite element analyses were conducted to clarify the role of corrosion product films (CPFs) in stress corrosion cracking (SCC). Flat and U-shaped edge-notched specimens were investigated in terms of the CPF-induced stress in the metallic substrate and the stress in the CPF. For a U-shaped edge-notched specimen, the stress field in front of the notch tip is affected by the Young's modulus of the CPF and the CPF thickness and notch geometry. The CPF-induced tensile stress in the metallic substrate is superimposed on the applied load to increase the crack tip strain and facilitate localized plasticity deformation. In addition, the stress in the CPF surface contributes to the rupture of the CPFs. The results provide physical insights into the role of CPFs in SCC.

  2. Corrosion product behavior in VVER secondary systems

    Energy Technology Data Exchange (ETDEWEB)

    Yurmanov, V.A.; Velikopolsky, S.V.; Yurmanov, E.V. [N.A. Dollezhal Research and Development Inst. of Power Engineering (NIKIET), Moscow (Russian Federation)

    2010-07-01

    Accumulation of corrosion products lead to some problems during long-term operation of VVER plants, such as secondary system component degradation including crud-induced local corrosion and corrosion cracking. Corrosion sludge and deposit removal from steam generators and other equipment is costly and time-consuming and leads to additional waste production. This problem is vital in the case of plant life extension. Appropriate solutions of the problem could be developed based on both Russian and international experience of the VVER fleet. Recommendations on how to mitigate corrosion product accumulation in VVER secondary systems were developed based on comparative analysis of available long-term data on corrosion product behavior in all the operating VVER plants, such as the following: Sludge and deposit accumulation in inner surfaces of secondary piping and components; Corrosion rate measurements using in-situ specimen testing at operated VVER plants; Efficiency of corrosion product removal from secondary system water by means of condensate polishers and steam generator blowdown cleanup systems; Sludge and deposit removal from steam generators during chemical cleaning; Secondary piping and components conservation efficiency during long outages. Comparative data analysis of corrosion product behavior has shown different corrosion product accumulation rates in Novovoronezh, Kola, Kalinin, Balakovo and Rostov NPPs. The said difference is due to different design and operation peculiarities. (author)

  3. Development of green vapour corrosion inhibitor

    Science.gov (United States)

    Asmara, Y. P.; Suraj, V.; Siregar, J. P.; Kurniawan, T.; Bachtiar, D.; Mohamed, N. M. Z. N.

    2017-10-01

    Corrosion control using inhibitor is an effective method to protect carbon steel from corrosion. Due to environmental toxicity of chemical inorganic corrosion inhibitors (synthetic), green inhibitors are potentially to develop. In atmospheric conditions, green vapour corrosion inhibitors are the best solutions to replace the uses of inorganic corrosion inhibitors. This research used chemical acid extraction from the key lime (citrus aurantiifolia) leaves and seeds. They are used as the main ingredients to produce this effective green corrosion inhibitor. The experiments investigated effects of corrosion inhibition on corrosion rate of low carbon steel in 3% NaCl solution using both fog salt chamber and electrochemical cell. Using salt fog chamber to represent atmospheric conditions, and corrosion rates are evaluated visually and calculated using weight loss methods. Corrosion rate on electrochemical cell were calculated using linear polarization resistance (LPR) methods. All of the experiments were set in natural conditions at pH 7. Using weight loss for three days exposure time, the efficiency of the inhibitor reached 82.39%.

  4. Corrosion Protection of Electrically Conductive Surfaces

    Directory of Open Access Journals (Sweden)

    Jian Song

    2012-11-01

    Full Text Available The basic function of the electrically conductive surface of electrical contacts is electrical conduction. The electrical conductivity of contact materials can be largely reduced by corrosion and in order to avoid corrosion, protective coatings must be used. Another phenomenon that leads to increasing contact resistance is fretting corrosion. Fretting corrosion is the degradation mechanism of surface material, which causes increasing contact resistance. Fretting corrosion occurs when there is a relative movement between electrical contacts with surfaces of ignoble metal. Avoiding fretting corrosion is therefore extremely challenging in electronic devices with pluggable electrical connections. Gold is one of the most commonly used noble plating materials for high performance electrical contacts because of its high corrosion resistance and its good and stable electrical behavior. The authors have investigated different ways to minimize the consumption of gold for electrical contacts and to improve the performance of gold plating. Other plating materials often used for corrosion protection of electrically conductive surfaces are tin, nickel, silver and palladium. This paper will deal with properties and new research results of different plating materials in addition to other means used for corrosion protection of electrically conductive surfaces and the testing of corrosion resistance of electrically conductive surfaces.

  5. ¡París!

    Directory of Open Access Journals (Sweden)

    Beatriz Caballero

    2003-01-01

    Full Text Available El día no le alcanzaba para caminarlo. Conocía cada puente, cada calle,plaza, museo, rincón, iglesia, café, y la mesa con el mejor ángulo para mirar siempre una iglesia, ojalá Saint-Germain-des-Pres, o Notre-Dame. Siempre contaba la impresión que le había causado a Bolívar ver allí cuando el papa coronó a Napoleón. Él se iba para la oficina todos los días, Luis a un taller a pintar, Antonio a estudiar ciencias políticas, yo al colegio y mamá hacía las cosas prácticas. Aprendíamos francés todos al tiempo y por la noche nos contábamos lo nuevo que cada uno había aprendido. Mamá después, cuando ya se quería volver, decía que París nos había maleado a todos. Estaba en pleno furor el cine francés de la "nueva ola", pero ella sólo me llevaba a ver películas de vaqueros pues no se fiaba de la clasificación de los periódicos.

  6. 49 CFR 192.477 - Internal corrosion control: Monitoring.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Internal corrosion control: Monitoring. 192.477... Control § 192.477 Internal corrosion control: Monitoring. If corrosive gas is being transported, coupons... internal corrosion. Each coupon or other means of monitoring internal corrosion must be checked two times...

  7. 49 CFR 192.491 - Corrosion control records.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Corrosion control records. 192.491 Section 192.491... BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Requirements for Corrosion Control § 192.491 Corrosion... detail to demonstrate the adequacy of corrosion control measures or that a corrosive condition does not...

  8. Space Shuttle Corrosion Protection Performance

    Science.gov (United States)

    Curtis, Cris E.

    2007-01-01

    The reusable Manned Space Shuttle has been flying into Space and returning to earth for more than 25 years. The launch pad environment can be corrosive to metallic substrates and the Space Shuttles are exposed to this environment when preparing for launch. The Orbiter has been in service well past its design life of 10 years or 100 missions. As part of the aging vehicle assessment one question under evaluation is how the thermal protection system and aging protective coatings are performing to insure structural integrity. The assessment of this cost resources and time. The information is invaluable when minimizing risk to the safety of Astronauts and Vehicle. This paper will outline a strategic sampling plan and some operational improvements made by the Orbiter Structures team and Corrosion Control Review Board.

  9. Corrosion-Activated Micro-Containers for Environmentally Friendly Corrosion Protective Coatings

    Science.gov (United States)

    Li, Wenyan; Buhrow, J. W.; Zhang, X.; Johnsey, M. N.; Pearman, B. P.; Jolley, S. T.; Calle, L. M.

    2016-01-01

    This work concerns the development of environmentally friendly encapsulation technology, specifically designed to incorporate corrosion indicators, inhibitors, and self-healing agents into a coating, in such a way that the delivery of the indicators and inhibitors is triggered by the corrosion process, and the delivery of self-healing agents is triggered by mechanical damage to the coating. Encapsulation of the active corrosion control ingredients allows the incorporation of desired autonomous corrosion control functions such as: early corrosion detection, hidden corrosion detection, corrosion inhibition, and self-healing of mechanical damage into a coating. The technology offers the versatility needed to include one or several corrosion control functions into the same coating.The development of the encapsulation technology has progressed from the initial proof-of-concept work, in which a corrosion indicator was encapsulated into an oil-core (hydrophobic) microcapsule and shown to be delivered autonomously, under simulated corrosion conditions, to a sophisticated portfolio of micro carriers (organic, inorganic, and hybrid) that can be used to deliver a wide range of active corrosion ingredients at a rate that can be adjusted to offer immediate as well as long-term corrosion control. The micro carriers have been incorporated into different coating formulas to test and optimize the autonomous corrosion detection, inhibition, and self-healing functions of the coatings. This paper provides an overview of progress made to date and highlights recent technical developments, such as improved corrosion detection sensitivity, inhibitor test results in various types of coatings, and highly effective self-healing coatings based on green chemistry. The NASA Kennedy Space Centers Corrosion Technology Lab at the Kennedy Space Center in Florida, U.S.A. has been developing multifunctional smart coatings based on the microencapsulation of environmentally friendly corrosion

  10. Corrosion: how to control it?

    OpenAIRE

    Hidalgo Serra, Ernest; Legrand, Erika; Toenders, Frank

    2009-01-01

    PFC presentat a Oslo University College and Oslo Heart Center Established in 1989, Oslo Heart Centre (OHC) is located in downtown Oslo, Norway. The hospital is a non-profit cardiac surgical clinic. To control the temperature in the hospital during the summer months, an air-conditioning system is installed. The ten years old air-conditioning system suffers from corrosion problems, inside and outside stainless steel pipes. The aim of this project is to find solutions in order to ...

  11. Corrosion resistant PEM fuel cell

    Science.gov (United States)

    Li, Y.; Meng, W.J.; Swathirajan, S.; Harris, S.J.; Doll, G.L.

    1997-04-29

    The present invention contemplates a PEM fuel cell having electrical contact elements (including bipolar plates/septums) comprising a titanium nitride coated light weight metal (e.g., Al or Ti) core, having a passivating, protective metal layer intermediate the core and the titanium nitride. The protective layer forms a barrier to further oxidation/corrosion when exposed to the fuel cell`s operating environment. Stainless steels rich in Cr, Ni, and Mo are particularly effective protective interlayers. 6 figs.

  12. Electrochemical corrosion testing of metal waste forms

    Energy Technology Data Exchange (ETDEWEB)

    Abraham, D. P.; Peterson, J. J.; Katyal, H. K.; Keiser, D. D.; Hilton, B. A.

    1999-12-14

    Electrochemical corrosion tests have been conducted on simulated stainless steel-zirconium (SS-Zr) metal waste form (MWF) samples. The uniform aqueous corrosion behavior of the samples in various test solutions was measured by the polarization resistance technique. The data show that the MWF corrosion rates are very low in groundwaters representative of the proposed Yucca Mountain repository. Galvanic corrosion measurements were also conducted on MWF samples that were coupled to an alloy that has been proposed for the inner lining of the high-level nuclear waste container. The experiments show that the steady-state galvanic corrosion currents are small. Galvanic corrosion will, hence, not be an important mechanism of radionuclide release from the MWF alloys.

  13. Time Dependent Development of Aluminium Pitting Corrosion

    Directory of Open Access Journals (Sweden)

    Robert E. Melchers

    2015-01-01

    Full Text Available Aluminium alloys have excellent corrosion resistance to a wide variety of exposure conditions. Usually they corrode by pitting rather than by uniform corrosion. For infrastructure applications long-term corrosion behaviour is of interest. The relatively limited long-term pitting data that is available shows that maximum and average pit depths do not follow the power law function as conventionally assumed but tend to follow a bimodal trend with exposure time. This is consistent with the bimodal trends observed previously for corrosion mass loss of aluminium alloys. Most likely it is the result of the accumulation of corrosion products over the pit mouths, leading to the gradual development of localised anoxic conditions within pits. In turn this permits the development within the pits of anoxic autocatalytic conditions, consistent with established theory for pitting corrosion of aluminium. It also is consistent with observations of hydrogen evolution from pits. The implications of this for practical applications are discussed.

  14. Evaluation of corrosion attack of chimney liners

    Directory of Open Access Journals (Sweden)

    Blahetová M.

    2016-06-01

    Full Text Available The case study of chimney liner corrosion addresses three specific cases of damage of chimney systems from of stainless steels. These systems were used for flue of gas arising from the combustion of brown coal in small automatic boilers, which are used for heating. Detailed analyzes implied that the cause of devastating corrosion of the steel AISI 316 and 304 steel (CSN 17349, 17241 was particularly high content of halides (chlorides and fluorides, which caused a severe pitting corrosion, which led up to the perforation of the liner material. Simultaneous reduction of the thickness of the used sheets was due to by the general corrosion, which was caused by the sulfur in the solid fuel. The condensation then led to acid environment and therefore the corrosion below the dew point of the sulfuric acid has occurred. All is documented by metallographic analysis and microanalysis of the corrosion products.

  15. Corrosion Properties of Laser Welded Stainless Steel

    DEFF Research Database (Denmark)

    Weldingh, Jakob; Olsen, Flemmming Ove

    1997-01-01

    In this paper the corrosion properties of laser welded AISI 316L stainless steel are examined. A number of different welds has been performed to test the influence of the weld parameters of the resulting corrosion properties. It has been chosen to use the potential independent critical pitting...... temperature (CPT) test as corrosion test. The following welding parameters are varied: Welding speed, lsser power, focus point position and laser operation mode (CW or pulsed)....

  16. Optimising corrosion monitoring in district heating systems

    DEFF Research Database (Denmark)

    Hilbert, Lisbeth Rischel; Thorarinsdottir, R.I.; Andersen, A.

    2002-01-01

    A three-year project - financially supported by the Nordic Industrial Fund - on monitoring of corrosion in district heating systems has been initiated with participation of researchers and industrial partners in Denmark, Finland, Iceland, Norway and Sweden. The primary objective of the project...... is to improve the quality control in district heating systems by corrosion monitoring. In Danish systems electrochemical impedance spectroscopy (EIS), linear polarisation resistance (LPR), high-sensitive electrical resistance (ER) technology, crevice corrosion probes, as well as weight loss coupons...

  17. Recognition and Analysis of Corrosion Failure Mechanisms

    OpenAIRE

    Steven Suess

    2006-01-01

    Corrosion has a vast impact on the global and domestic economy, and currently incurs losses of nearly $300 billion annually to the U.S. economy alone. Because of the huge impact of corrosion, it is imperative to have a systematic approach to recognizing and mitigating corrosion problems as soon as possible after they become apparent. A proper failure analysis includes collection of pertinent background data and service history, followed by visual inspection, photographic documentation, materi...

  18. Some peculiarities of corrosion of wheel steel

    OpenAIRE

    Alexander SHRAMKO; Alfred KOZLOWSKY; Elena BELAJA; Yuriy PROIDAK; Sofia PINCHUK; Svetlana GUBENKO

    2009-01-01

    Corrosion mechanism and rate of different chemical composition and structural condition of wheel steel were investigated. It was shown that “white layers”, variation in grain size and banding of wheel steel structure results in corrosion rate. Microstructure of steel from different elements of railway wheels after operation with corrosion was investigated. Wheel steel with addition of vanadium corroded more quickly than steel without vanadium. Non-metallic inclusions are the centre of corrosi...

  19. Corrosive acid injury of the stomach.

    Science.gov (United States)

    Wijeratne, T; Ratnatunga, C; Dharrmapala, A; Samarasinghe, T

    2015-03-01

    Ingestion of corrosives with accidental or suicidal intent is a common problem in Sri Lanka. Management options and outcomes of corrosive injuries on stomach are not well documented in our setting. The clinical presentation, complications and management outcomes of nine patients with corrosive injury to stomach are presented. Gastric outlet obstruction seen in majority, was managed with bypass procedure (n=5) or resection (n=4). The outcomes of management were successful with both methods.

  20. Natural analogues of nuclear waste glass corrosion.

    Energy Technology Data Exchange (ETDEWEB)

    Abrajano, T.A. Jr.; Ebert, W.L.; Luo, J.S.

    1999-01-06

    This report reviews and summarizes studies performed to characterize the products and processes involved in the corrosion of natural glasses. Studies are also reviewed and evaluated on how well the corrosion of natural glasses in natural environments serves as an analogue for the corrosion of high-level radioactive waste glasses in an engineered geologic disposal system. A wide range of natural and experimental corrosion studies has been performed on three major groups of natural glasses: tektite, obsidian, and basalt. Studies of the corrosion of natural glass attempt to characterize both the nature of alteration products and the reaction kinetics. Information available on natural glass was then compared to corresponding information on the corrosion of nuclear waste glasses, specifically to resolve two key questions: (1) whether one or more natural glasses behave similarly to nuclear waste glasses in laboratory tests, and (2) how these similarities can be used to support projections of the long-term corrosion of nuclear waste glasses. The corrosion behavior of basaltic glasses was most similar to that of nuclear waste glasses, but the corrosion of tektite and obsidian glasses involves certain processes that also occur during the corrosion of nuclear waste glasses. The reactions and processes that control basalt glass dissolution are similar to those that are important in nuclear waste glass dissolution. The key reaction of the overall corrosion mechanism is network hydrolysis, which eventually breaks down the glass network structure that remains after the initial ion-exchange and diffusion processes. This review also highlights some unresolved issues related to the application of an analogue approach to predicting long-term behavior of nuclear waste glass corrosion, such as discrepancies between experimental and field-based estimates of kinetic parameters for basaltic glasses.

  1. Preventing Corrosion by Controlling Cathodic Reaction Kinetics

    Science.gov (United States)

    2016-03-25

    Preventing corrosion by controlling cathodic reaction kinetics Progress Report for Period: 1 SEP 2015-31 MAR 2016 John Keith Department of...25 March 2016 Preventing corrosion by controlling cathodic reaction kinetics Annual Summary Report: FY16 PI: John Keith, 412-624-7016,jakeith...elements on the kinetics of oxygen reduction reaction catalyzed on titanium oxide in order to develop new approaches for controlling galvanic corrosion

  2. Assessment of Mortar Corrosion by Sulphuric Acid

    OpenAIRE

    Kawahigashi, Tatsuo

    2008-01-01

    In order to study the corrosion mechanisms of water-cement system, cement mortar specimens were immersed in the sulphuric acid solution. Over the periods, changes to the roughened surfaces, mass change and neutralization depth were observed. Corrosion of cement mortar progressed through chemical reaction of sulphuric acid and ion transport in mortar. Relations between the environment operation of sulphuric acid and the corrosion (summation of chemical erosion and neutralization depth) of test...

  3. Corrosion problems and solutions in oil refining and petrochemical industry

    CERN Document Server

    Groysman, Alec

    2017-01-01

    This book addresses corrosion problems and their solutions at facilities in the oil refining and petrochemical industry, including cooling water and boiler feed water units. Further, it describes and analyzes corrosion control actions, corrosion monitoring, and corrosion management. Corrosion problems are a perennial issue in the oil refining and petrochemical industry, as they lead to a deterioration of the functional properties of metallic equipment and harm the environment – both of which need to be protected for the sake of current and future generations. Accordingly, this book examines and analyzes typical and atypical corrosion failure cases and their prevention at refineries and petrochemical facilities, including problems with: pipelines, tanks, furnaces, distillation columns, absorbers, heat exchangers, and pumps. In addition, it describes naphthenic acid corrosion, stress corrosion cracking, hydrogen damages, sulfidic corrosion, microbiologically induced corrosion, erosion-corrosion, and corrosion...

  4. Propagation of steel corrosion in concrete: Experimental and numerical investigations

    DEFF Research Database (Denmark)

    Michel, Alexander; Otieno, M.; Stang, Henrik

    2016-01-01

    This paper focuses on experimental and numerical investigations of the propagation phase of reinforcement corrosion to determine anodic and cathodic Tafel constants and exchange current densities, from corrosion current density and corrosion potential measurements. The experimental program includ...

  5. Corrosion and wear resistant metallic layers produced by electrochemical methods

    DEFF Research Database (Denmark)

    Christoffersen, Lasse; Maahn, Ernst Emanuel

    1999-01-01

    Corrosion and wear-corrosion properties of novel nickel alloy coatings with promising production characteristics have been compared with conventional bulk materials and hard platings. Corrosion properties in neutral and acidic environments have been investigated with electrochemical methods...

  6. Real time corrosion monitoring in atmosphere using automated battery driven corrosion loggers

    DEFF Research Database (Denmark)

    Prosek, T.; Kouril, M.; Hilbert, Lisbeth Rischel

    2008-01-01

    diminishes due to corrosion. Zinc, iron, copper and nickel sensors at several thicknesses are available. Sensitivity of the corrosion measurement varies from 1 to 10 nm depending on the type and thickness of the sensor. Changes in the air corrosivity can be thus detected within hours or even tens of minutes...

  7. Corrosion Fatigue in District Heating Water Tanks

    DEFF Research Database (Denmark)

    Maahn, Ernst Emanuel

    1996-01-01

    Three candidate materials for construction of buffer tanks for district heating water have been tested for corrosion fatigue properties in a district heating water environment. The investigation included Slow Strain Rate Testing of plain tensile specimens, crack initiation testing by corrosion...... fatigue of plain tensile specimens and crack growth rate determination for Compact Tensile Specimens under corrosion fatigue conditions. The three materials are equal with respect to stress corrosion sensibility and crack initiation. Crack growth rate is increased with a factor of 4-6 relative to an inert...

  8. New corrosion issues in gas sweetening plants

    Energy Technology Data Exchange (ETDEWEB)

    Asperger, R.G. (CLI International and Asperger Technologies, Houston, TX (United States))

    Gas treating plants are experiencing corrosion problems which impact on efficiency and safety. While general corrosion is not particularly hazardous in the gas processing industry, local corrosion is very dangerous since it has several different mechanisms, all of which have dangerously high rates, and it occurs at locations which are hard to find and hard to predict. A newly discovered, velocity-dependent type of corrosion is reported. It is related to yet-undefined species which cause excessively high corrosion in areas of turbulence. This accelerated corrosion is not due to erosion or cavitation, but to a diffusion-limited reaction accelerated by turbulence. A full-flow test loop was built to evaluate the corrosiveness of gas plant solutions at their normal temperature and flow rates. Test runs were conducted with Co[sub 2]-loaded amine solutions for periods of 12 days. Carbon steel specimens mounted in the test loop were examined and corrosion rates calculated. Chromium alloys were shown to be attacked by corrodents in the low-velocity part of the loop and very aggressively attacked in the high-velocity part. The tests demonstrate the need for rigorous monitoring of corrosion in areas of higher velocity such as piping elbows and other points of turbulence. 5 refs., 2 figs., 3 tabs.

  9. Emerging Corrosion Inhibitors for Interfacial Coating

    Directory of Open Access Journals (Sweden)

    Mona Taghavikish

    2017-12-01

    Full Text Available Corrosion is a deterioration of a metal due to reaction with environment. The use of corrosion inhibitors is one of the most effective ways of protecting metal surfaces against corrosion. Their effectiveness is related to the chemical composition, their molecular structures and affinities for adsorption on the metal surface. This review focuses on the potential of ionic liquid, polyionic liquid (PIL and graphene as promising corrosion inhibitors in emerging coatings due to their remarkable properties and various embedment or fabrication strategies. The review begins with a precise description of the synthesis, characterization and structure-property-performance relationship of such inhibitors for anti-corrosion coatings. It establishes a platform for the formation of new generation of PIL based coatings and shows that PIL corrosion inhibitors with various heteroatoms in different form can be employed for corrosion protection with higher barrier properties and protection of metal surface. However, such study is still in its infancy and there is significant scope to further develop new structures of PIL based corrosion inhibitors and coatings and study their behaviour in protection of metals. Besides, it is identified that the combination of ionic liquid, PIL and graphene could possibly contribute to the development of the ultimate corrosion inhibitor based coating.

  10. Fouling corrosion in aluminum heat exchangers

    Directory of Open Access Journals (Sweden)

    Su Jingxin

    2015-06-01

    Full Text Available Fouling deposits on aluminum heat exchanger reduce the heat transfer efficiency and cause corrosion to the apparatus. This study focuses on the corrosive behavior of aluminum coupons covered with a layer of artificial fouling in a humid atmosphere by their weight loss, Tafel plots, electrochemical impedance spectroscopy (EIS, and scanning electron microscope (SEM observations. The results reveal that chloride is one of the major elements found in the fouling which damages the passive film and initiates corrosion. The galvanic corrosion between the metal and the adjacent carbon particles accelerates the corrosive process. Furthermore, the black carbon favors the moisture uptake, and gives the dissolved oxygen greater chance to migrate through the fouling layer and form a continuous diffusive path. The corrosion rate decreasing over time is conformed to electrochemistry measurements and can be verified by Faraday’s law. The EIS results indicate that the mechanism of corrosion can be interpreted by the pitting corrosion evolution mechanism, and that pitting was observed on the coupons by SEM after corrosive exposure.

  11. Influence of corrosion layers on quantitative analysis

    Science.gov (United States)

    Denker, A.; Bohne, W.; Opitz-Coutureau, J.; Rauschenberg, J.; Röhrich, J.; Strub, E.

    2005-09-01

    Art historians and restorers in charge of ancient metal objects are often reluctant to remove the corrosion layer evolved over time, as this would change the appearance of the artefact dramatically. Therefore, when an elemental analysis of the objects is required, this has to be done by penetrating the corrosion layer. In this work the influence of corrosion was studied on Chinese and Roman coins, where removal of oxidized material was possible. Measurements on spots with and without corrosion are presented and the results discussed.

  12. C9.A/14 steelwork joints de poutres par plaque frontale : assemblages par gousset

    CERN Document Server

    2015-01-01

    Les Tables de résistances ultimes des assemblages boulonnés par plaque frontale et par gousset, complétées par une description des modèles de calcul et des exemples d’application, ont pour but de faciliter la tâche de l'ingénieur et du constructeur. Cette première partie C9.A/14 contient les chapitres suivants: - Joints de poutres par plaque frontale en acier S235 et S355 - Assemblages par gousset en acier S235 et S355 Les Tables contiennent des données relatives à la géométrie ainsi que les valeurs de calcul correspondantes des résistances ultimes des assemblages ; elles remplacent le chapitre « Assemblages par plaques frontales et boulons HR » des anciennes Tables C9.1 de 1983 / 2002. Le calcul de ces assemblages par plaque frontale est basé sur les hypothèses du modèle de la méthode des composants décrite dans la norme SN EN 1993-1-8. Les vérifications sont effectuées selon la norme SIA 263:2013. Les assemblages par gousset remplacent les assemblages par double cornière, (telle...

  13. Initiation and Growth of Corrosion Pit and Its Effect on Corrosion Fatigue Strength in 12Cr Stainless Steel

    National Research Council Canada - National Science Library

    HAYASHI, Makoto; AMANO, Kazuo; UEYAMA, Yoshiharu

    2017-01-01

    .... The corrosion fatigue cracks often initiate from the pits. In order to prevent the corrosion fatigue failure, 12Cr stainless steel is employed for the components used in the corrosive environments...

  14. Corrosion protection performance of corrosion inhibitors and epoxy-coated reinforcing steel in a simulated concrete pore water solution.

    Science.gov (United States)

    1998-06-01

    We used a simulated concrete pore water solution to evaluate the corrosion protection performance of concrete corrosion-inhibiting admixtures and epoxy-coated reinforcing bars (ECR). We evaluated three commercial corrosion inhibitors, ECR from three ...

  15. The effect of organic matter associated with the corrosion products on the corrosion of mild steel in the Arabian Sea

    Digital Repository Service at National Institute of Oceanography (India)

    Bhosle, N.B.; Wagh, A.B.

    the corrosion of mild steel and the temperature and dissolved oxygen of seawater. In contrast to this, the corrosion and mild steel was inversely related to the organic carbon and water extractable carbohydrates associated with the corrosion products of mild...

  16. Civil Engineering Corrosion Control. Volume 1. Corrosion Control - General

    Science.gov (United States)

    1975-01-01

    Cathodic Protection 3 3-1 Schematic Diagrama of Atoms, Molecules, Ions lb 3-2 The Basic Corrosion Cell 20 3-3 Effect of Moisture Content on Resistivity of...when examined immedi- ately after excavation - a gray " frost " covers the black"paste". When the paste is washed from steel with water, shiny bright...concrete structures are encountered where frost prevails, in sea water, in sulfate-bearing environ- ments, in acid soils and waters, with sugar waters

  17. Rôle des bactéries sulfurogènes dans la corrosion du fer Involvment of Sulfidogenic Bacteria in Iron Corrosion

    Directory of Open Access Journals (Sweden)

    Marchal R.

    2006-12-01

    Full Text Available Cet article fait le point sur les connaissances concernant l'implication des bactéries sulfurogènes dans la corrosion des aciers au carbone. Après la description de quelques cas récents tirés de l'industrie pétrolière, la physiologie des bactéries sulfurogènes qui jouent le rôle principal dans le mécanisme de la corrosion anaérobie d'origine bactérienne est examinée. La participation des bactéries productrices d'H2S à la constitution de biofilms est une condition importante à la manifestation des phénomènes de corrosion. Les différentes hypothèses de mécanismes décrites par la littérature sont passées en revue. Indépendamment du rôle physicochirnique joué par les sulfures de fer, non couvrants, bons conducteurs électriques, il en ressort que l'acidification résultant du métabolisme cellulaire est un facteur crucial, non seulement en termes d'électrochimie, mais également en termes de croissance microbienne. L'acidification métabolique explique vraisemblablement la fourniture des ions ferreux pour le micro-organisme dans un environnement chargé d'ions sulfures et finalement la persistance de son activité physiologique dans un micro environnement riche en H2S. The involvement of sulfidogenic bacteria in the corrosion of carbon steel is reviewed. After a brief description of some recent cases drawn from the petroleum industry, the physiology of the sulfidogenic bacteria which plays the most important role in the mechanism of anaerobic bacterial corrosion is examined. The involvement of H2S-producing bacteria to the biofilm formation is a prerequisite for biocorrosion. The hypothetical mechanisms described in the literature are reviewed. Regardless of the physicochemical role played by iron sulfides, which have been shown to be non-covering and to have good properties of electric conductivity, the acidification arising from cellular metabolism has been found to be an important parameter, not only in terms of

  18. High Temperature Corrosion under Laboratory Conditions Simulating Biomass-Firing: A Comprehensive Characterization of Corrosion Products

    DEFF Research Database (Denmark)

    Okoro, Sunday Chukwudi; Montgomery, Melanie; Jappe Frandsen, Flemming

    2014-01-01

    characterization of the corrosion products. The corrosion products consisted of three layers: i) the outermost layer consisting of a mixed layer of K2SO4 and FexOy on a partly molten layer of the initial deposit, ii) the middle layer consists of spinel (FeCr2O4) and Fe2O3, and iii) the innermost layer is a sponge......-like Ni3S2 containing layer. At the corrosion front, Cl-rich protrusions were observed. Results indicate that selective corrosion of Fe and Cr by Cl, active oxidation and sulphidation attack of Ni are possible corrosion mechanisms....

  19. Detection of corrosion in submerged reinforced concrete

    Energy Technology Data Exchange (ETDEWEB)

    Carney, R.F.A.; Lawrence, P.F.; Wilkins, N.J.M. [UKAEA Harwell Lab. (United Kingdom). Materials Development Div.

    1990-12-31

    Steel reinforcement in concrete is not usually subject to corrosion when it is under water and not exposed to air. However, research carried out within the Concrete in the Oceans Programme has produced evidence that localised corrosion can occur at cracks which intersect the reinforcing bars even though the concrete is fully immersed in seawater. The problem with underwater corrosion is that, although the corrosion products migrate out of the crack and slight rust staining appears, these are not easy to see. In contrast, when reinforced concrete is exposed to air, then corrosion is marked by expansive rust deposits and spalling concrete. The principal objective of this report was to define the conditions of crack geometry, electrochemical potential and rate of seawater flow, under which there would be no external visible signs of corrosion. A further objective was to define, on a concrete offshore platform, where this type of unseen corrosion is most likely to occur. At seawater flowrates of 0.25 metres per second or less, localised corrosion occurring at cracks in the concrete which intersected the reinforcing bars was only visible as rust staining or deposits near the crack. At higher flowrates there was no clear visual evidence of corrosion. Visual inspection is therefore not a reliable method of checking on the presence of corrosion in underwater concrete structures. It is also concluded than an overall underwater potential of -700 mV Ag/AgCl or more negative is required in order to dismiss the possibility of localized corrosion occurring at cracks. (author)

  20. Field corrosion characterization of soil corrosion of X70 pipeline steel in a red clay soil

    Directory of Open Access Journals (Sweden)

    Shengrong Wang

    2015-06-01

    Full Text Available The corrosion behavior of X70 pipeline steel buried in red soil environment has been studied. The surface morphology and elemental distribution were determined by scanning electron microscopy (SEM,energy dispersive X-ray spectroscopy (EDS, and X-ray diffraction (XRD. The corrosion kinetics was evaluated by weight loss measurement. The results show that in red soil, the corrosion rate of X70 steel decreases with time, and follows the exponential decay law. General corrosion with non-uniform and localized pitting occurred on the steel surface. α-FeOOH was the dominate products during corrosion in whole buried periods, and the corrosion products exhibited well protective properties. The potentiodynamic polarization tests revealed that icorr decreased with time, indicating the improvement of corrosion resistance. The results of Electrochemical impendence spectroscopy (EIS are consistent with potentiodynamic polarization tests.

  1. Corrosion avoidance with new wood preservatives

    Science.gov (United States)

    Samuel L. Zelinka; Douglas R. Rammer

    2006-01-01

    The increased use of alkaline copper quaternary (ACQ) and copper azole (CuAz) as wood preservatives for residential construction has led to concerns about the corrosion performance of fasteners. Information on the effects of these preservatives on the corrosion rate is limited, although Simpson Strong Tie has published a technical bulletin indicating that both ACQ and...

  2. Threshold Corrosion Fatigue of Welded Shipbuilding Steels.

    Science.gov (United States)

    1992-01-01

    8. J. C. Walter, E. Olbjorn, 0. Allstad and G. Elde, "Safety Against Corrosion Fatigue Offshore," Publication No. 94, Det Norske Ventas , Horik...Offshore. Publication No;. 94;, Det Norske Ventas , Horik, Norway, April 1976. 18. C. E. Jaske, D. Broek, J. E. Slater, W. E. Anderson. Corrosion Fatigue

  3. Corrosion of carbon-alloyed iron aluminides

    Indian Academy of Sciences (India)

    Potentiodynamic polarization studies indicated that the intermetallics exhibited active–passive behaviour in an acidic solution of pH = 1, whereas they exhibited stable passivity in a buffer solution of pH 8.4. Corrosion rates were also obtained by immersion testing. The variation of corrosion rate as a function of time was ...

  4. Corrosion Behaviour of New Zr Alloys

    DEFF Research Database (Denmark)

    Tolksdorf, E.

    1974-01-01

    Corrosion studies have indicated that the most promising replacements for Zicaloy-2 are ZrCrFe, ZrVFe and probably ZrNbTa, provided they are in their optimized condition. These alloys are conventionally manufactured alloys. An internally oxidized ZrMgO alloy is even superior, from the corrosion...

  5. Ampicillin potentials as Corrosion Inhibitor: fukui function ...

    African Journals Online (AJOL)

    Inhibition and adsorption potentials of ampicillin for the corrosion of mild steel in solutions of HCl have been investigated using empirical and computational approach. The experimental study was carried out using gravimetric and Fourier transform infrared spectroscopy methods of monitoring corrosion while the ...

  6. Electrochemical corrosion measurements on noble electrodeposits

    DEFF Research Database (Denmark)

    Christoffersen, Lasse; Maahn, Ernst Emanuel

    1998-01-01

    Novel electrodeposits are compared with hard chrome and electroless Ni-P with respect to production, corrosion resistance and hardness.......Novel electrodeposits are compared with hard chrome and electroless Ni-P with respect to production, corrosion resistance and hardness....

  7. Internal Corrosion Detection in Liquids Pipelines

    Science.gov (United States)

    2012-01-01

    PHMSA project DTRS56-05-T-0005 "Development of ICDA for Liquid Petroleum Pipelines" led to the development of a Direct Assessment (DA) protocol to prioritize locations of possible internal corrosion. The underlying basis LP-ICDA is simple; corrosion ...

  8. The dual role of microbes in corrosion

    NARCIS (Netherlands)

    Kip, D.J.; Van Veen, J.A.

    2015-01-01

    Corrosion is the result of a series of chemical, physical and (micro) biological processes leading to the deterioration of materials such as steel and stone. It is a world-wide problem with great societal and economic consequences. Current corrosion control strategies based on chemically produced

  9. The Corrosivity of the Mauritian Atmosphere

    African Journals Online (AJOL)

    Nafiisah

    technology. Atmospheric corrosion is the major contributor to this cost (Natesan et.al, 2005). To prevent such losses in Mauritius, it has become important to classify the corrosivity of the Mauritian atmosphere in order to facilitate the task of selecting materials, protection systems, maintenance intervals, e.t.c. Therefore,.

  10. Geothermal drill pipe corrosion test plan

    Energy Technology Data Exchange (ETDEWEB)

    Caskey, B.C.; Copass, K.S.

    1980-12-01

    Plans are presented for conducting a field test of drill pipe corrosion, comparing air and nitrogen as drilling fluids. This test will provide data for evaluating the potential of reducing geothermal well drilling costs by extending drill pipe life and reducing corrosion control costs. The 10-day test will take place during fall 1980 at the Baca Location in Sandoval County, New Mexico.

  11. Vibrational Spectroscopy in Studies of Atmospheric Corrosion

    Directory of Open Access Journals (Sweden)

    Saman Hosseinpour

    2017-04-01

    Full Text Available Vibrational spectroscopy has been successfully used for decades in studies of the atmospheric corrosion processes, mainly to identify the nature of corrosion products but also to quantify their amounts. In this review article, a summary of the main achievements is presented with focus on how the techniques infrared spectroscopy, Raman spectroscopy, and vibrational sum frequency spectroscopy can be used in the field. Several different studies have been discussed where these instruments have been used to assess both the nature of corrosion products as well as the properties of corrosion inhibitors. Some of these techniques offer the valuable possibility to perform in-situ measurements in real time on ongoing corrosion processes, which allows the kinetics of formation of corrosion products to be studied, and also minimizes the risk of changing the surface properties which may occur during ex-situ experiments. Since corrosion processes often occur heterogeneously over a surface, it is of great importance to obtain a deeper knowledge about atmospheric corrosion phenomena on the nano scale, and this review also discusses novel vibrational microscopy techniques allowing spectra to be acquired with a spatial resolution of 20 nm.

  12. Factors affecting the corrosivity of pulping liquors

    Science.gov (United States)

    Hazlewood, Patrick Evan

    Increased equipment failures and the resultant increase in unplanned downtime as the result of process optimization programs continue to plague pulp mills. The failures are a result of a lack of understanding of corrosion in the different pulping liquors, specifically the parameters responsible for its adjustment such as the role and identification of inorganic and organic species. The current work investigates the role of inorganic species, namely sodium hydroxide and sodium sulfide, on liquor corrosivity at a range of process conditions beyond those currently experienced in literature. The role of sulfur species, in the activation of corrosion and the ability of hydroxide to passivate carbon steel A516-Gr70, is evaluated with gravimetric and electrochemical methods. The impact of wood chip weathering on process corrosion was also evaluated. Results were used to identify black liquor components, depending on the wood species, which play a significant role in the activation and inhibition of corrosion for carbon steel A516-Gr70 process equipment. Further, the effect of black liquor oxidation on liquor corrosivity was evaluated. Corrosion and stress corrosion cracking performance of selected materials provided information on classes of materials that may be reliably used in aggressive pulping environments.

  13. Aircraft Integral Fuel Tank Corrosion Study

    Science.gov (United States)

    2003-07-15

    biology of Amorphoteca resinae . Materials und Organismen, 6, (3), p. 161, (1971). 8. D. Cabral. Corrosion by microorganisms of jet aircraft integral fuel...the mycelium of the fungus Hormoconis resinae in the MIC of Al alloys. Proc. XI Int. Corrosion Congress, Houston, USA, 5B, p. 3773, (1993). 14. M

  14. Corrosion effects on soda lime glass

    NARCIS (Netherlands)

    Veer, F.A.; Rodichev, Y.M.

    2010-01-01

    Although soda lime glass is the most common used transparent material in architecture, little is known about the corrosion effects on long term strength and the interaction between corrosion and defects. Extensive testing on soda lime bars under different environmental conditions and different

  15. Corrosion problems with aqueous coolants, final report

    Energy Technology Data Exchange (ETDEWEB)

    Diegle, R B; Beavers, J A; Clifford, J E

    1980-04-11

    The results of a one year program to characterize corrosion of solar collector alloys in aqueous heat-transfer media are summarized. The program involved a literature review and a laboratory investigation of corrosion in uninhibited solutions. It consisted of three separate tasks, as follows: review of the state-of-the-art of solar collector corrosion processes; study of corrosion in multimetallic systems; and determination of interaction between different waters and chemical antifreeze additives. Task 1 involved a comprehensive review of published literature concerning corrosion under solar collector operating conditions. The reivew also incorporated data from related technologies, specifically, from research performed on automotive cooling systems, cooling towers, and heat exchangers. Task 2 consisted of determining the corrosion behavior of candidate alloys of construction for solar collectors in different types of aqueous coolants containing various concentrations of corrosive ionic species. Task 3 involved measuring the degradation rates of glycol-based heat-transfer media, and also evaluating the effects of degradation on the corrosion behavior of metallic collector materials.

  16. A Course in Electrochemical and Corrosion Engineering.

    Science.gov (United States)

    Van Zee, John

    1985-01-01

    Describes a course designed to show similarities between electrochemistry and corrosion engineering and to show graduate students that electrochemical and corrosion engineering can be accomplished by extending their knowledge of chemical engineering models. Includes course outline, textbooks selected, and teaching methods used. (JN)

  17. Microbiologically influenced corrosion in ship ballast tanks

    NARCIS (Netherlands)

    Heyer, A.

    2013-01-01

    Microbiologically influenced corrosion (MIC) is known to be a dangerous process in ship tanks due to its rapid and yet unpredictable occurrence, leading to extremely fast local corrosion, possibly jeopardizing the structural integrity, in a relatively short time. This project focuses on a

  18. Computer-Aided Corrosion Program Management

    Science.gov (United States)

    MacDowell, Louis

    2010-01-01

    This viewgraph presentation reviews Computer-Aided Corrosion Program Management at John F. Kennedy Space Center. The contents include: 1) Corrosion at the Kennedy Space Center (KSC); 2) Requirements and Objectives; 3) Program Description, Background and History; 4) Approach and Implementation; 5) Challenges; 6) Lessons Learned; 7) Successes and Benefits; and 8) Summary and Conclusions.

  19. General Corrosion and Localized Corrosion of the Drip Shield

    Energy Technology Data Exchange (ETDEWEB)

    F. Hua; K. Mon

    2003-06-24

    The recommended waste package (WP) design is described in BSC (2001a). The design includes a double-wall WP underneath a protective drip shield (DS) (BSC 2003a). The purpose of the process-level models developed in this report is to model dry oxidation (DOX), general corrosion (GC) and localized corrosion (LC) of the DS plate material, which is made of Ti Grade 7. The DS design also includes structural supports fabricated from Ti Grade 24. Degradation of Ti Grade 24 is not considered in this report. The DS provides protection for the waste package outer barrier (WPOB) both as a barrier to seepage water contact and a physical barrier to potential rockfall. This Model Report (MR) serves as a feed to the Integrated Waste Package Degradation Model (IWPD) analyses, and was developed in accordance with the Technical Work Plan (TWP) (BSC 2002a). The models contained in this report serve as a basis to determine whether or not the performance requirements for the DS can be met.

  20. CORROSION RATE OF STEELS DX51D AND S220GD IN DIFFERENT CORROSION ENVIRONMENT

    Directory of Open Access Journals (Sweden)

    Alina Crina CIUBOTARIU

    2016-06-01

    Full Text Available Corrosion in the marine environment is an important issue because the costs causes by marine corrosion increased year upon year. It is necessary a correctly approach to materials selection, protection and corrosion control to reduce this burden of wasted materials, wasted energy and wasted money. Many different types of corrosion attack can be observed to structures, ships and other equipment used in sea water service. Shipping containers are exposed to various corrosive mediums like as airborne salt, industrial pollutants, rain and saltwater. Transport damage during loading onto and unloading off trucks, train beds and ships breaches the paint coating which further contributes to corrosion. The result is shortened container life and high costs for container repair or replacement. The paper intends to evaluate, by gravimetric method, the corrosion rate and corrosion penetration rate of two types of carbon steel DX51D and S220GD. Carbon steel DX51D and hot-dip galvanized steel S220GD are used in marine and industrial applications for buildings cargo vessels, container ships and oil tankers. For testing it was used different corrosive environments: 5% NaOH solution; 5% HCL solution and 0.5M NaCl solution. The samples were immersed in 400mL of testing solution for exposure period of 28 days. Periodically at 3 days, 7 days, 14 days, 21 days and 28 days was measured de mass loss and evaluate the corrosion rate and corrosion stability coefficient. The steel DX51D was stable in 5% NaOH solution for 28 days, the values of corrosion stability coefficient was 7 after 3 days and 6 after 28 days of immersion in corrosive medium. In 5% HCL solution steels DX51D and S220GD was completely corroded in 21 days with a corrosion stability coefficient equal with 9 for 7 days and 8 for 21 days of immersion in corrosive solution. It was observed a good resistance for 3 days in 0.5M NaCl solution with a corrosion stability coefficient equal with 5, but after that

  1. Structural analysis of the ParR/parC plasmid partition complex

    DEFF Research Database (Denmark)

    Møller-Jensen, Jakob; Ringgaard, Simon; Mercogliano, Christopher P

    2007-01-01

    . coli plasmid pB171. ParR forms a tight dimer resembling a large family of dimeric ribbon-helix-helix (RHH)2 site-specific DNA-binding proteins. Crystallographic and electron microscopic data further indicate that ParR dimers assemble into a helix structure with DNA-binding sites facing outward. Genetic...

  2. Protease-activated receptor (PAR)-2 is required for PAR-1 signalling in pulmonary fibrosis

    NARCIS (Netherlands)

    Lin, Cong; von der Thüsen, Jan; Daalhuisen, Joost; ten Brink, Marieke; Crestani, Bruno; van der Poll, Tom; Borensztajn, Keren; Spek, C. Arnold

    2015-01-01

    Idiopathic pulmonary fibrosis is the most devastating diffuse fibrosing lung disease of unknown aetiology. Compelling evidence suggests that both protease-activated receptor (PAR)-1 and PAR-2 participate in the development of pulmonary fibrosis. Previous studies have shown that bleomycin-induced

  3. [Microbiological corrosion of aluminum alloys].

    Science.gov (United States)

    Smirnov, V F; Belov, D V; Sokolova, T N; Kuzina, O V; Kartashov, V R

    2008-01-01

    Biological corrosion of ADO quality aluminum and aluminum-based construction materials (alloys V65, D16, and D16T) was studied. Thirteen microscopic fungus species and six bacterial species proved to be able to attack aluminum and its alloys. It was found that biocorrosion of metals by microscopic fungi and bacteria was mediated by certain exometabolites. Experiments on biocorrosion of the materials by the microscopic fungus Alternaria alternata, the most active biodegrader, demonstrated that the micromycete attack started with the appearance of exudate with pH 8-9 on end faces of the samples.

  4. Corrosion-Resistant Acrylic Coatings

    Science.gov (United States)

    1992-03-31

    amount of a corrosion-inhibiting pigment system consisting essentially of critical amounts of at least one zinc phosphate , zinc molybdate and at least... phosphate , zinc , moiybdate and at least one zinc salt of a benzoic acid. 15 Claims, No Drawings 5,100,942 1 2 moDAcinv DrcicT.vT . -™v...8217VT’ T Z^ doned ’ by weight of at leas« one zinc phosphate , 40 «o 260 pans by weigh» of zinc molybdate, and 1 to 30 pans by BACKGROUND OF THE

  5. Corrosion-Resistant Alkyd Coatings

    Science.gov (United States)

    1992-02-18

    a corrosion-inhibiting pigment consisting essentially of critical amounts of at least one zinc phosphate , zinc molybdate and at least one zinc salt...of at leajt one 2inc phosphate , continuationi of application 07/211.026 filed June 16, 40 to 260 pans by weight cf zinc molybdate. and 1 to 30 1988... phosphate , zinc molybdate and a. tions of this invention, however, are resistant to harsh lea$t one zmc »•« of a benzoic acid. weather conditions and

  6. Microbial Influenced Corrosion (MIC) Study

    Science.gov (United States)

    2012-05-23

    corrosion morphology (i e tunneling suggests MIC) . ., Inner Surfaces BUSINESS SENSITIVE 6 Outer Surfaces Outer Surfaces Microbial Influenced...environmental conditions expected within areas of aircraft −Identify and assess the effect of possible short- and long- term mitigation technologies...DAY 28 Chrome Conversion Coating  Coupon Type: A    Alodine  1200 (Henkel)  Non‐Chrome Treatment  Coupon Type: E    Prekote® (Pantheon Chemical

  7. LES LESIONS DES ORGANES GENITAUX EXTERNES PAR ARME A

    African Journals Online (AJOL)

    Les lésions par arme à feu définies comme toute blessure produite sur le corps humain par rapprochement ou le choc d'une arme à feu, sont généralement rares qu'il s'agisse de plaies par armes de guerre ou de plaies par projectiles dans un contexte civil“. Parmi les facteurs de gravité des plaies par balles figu-.

  8. Launch Pad Coatings for Smart Corrosion Control

    Science.gov (United States)

    Calle, Luz M.; Hintze, Paul E.; Bucherl, Cori N.; Li, Wenyan; Buhrow, Jerry W.; Curran, Jerome P.; Whitten, Mary C.

    2010-01-01

    Corrosion is the degradation of a material as a result of its interaction with the environment. The environment at the KSC launch pads has been documented by ASM International (formerly American Society for Metals) as the most corrosive in the US. The 70 tons of highly corrosive hydrochloric acid that are generated by the solid rocket boosters during a launch exacerbate the corrosiveness of the environment at the pads. Numerous failures at the pads are caused by the pitting of stainless steels, rebar corrosion, and the degradation of concrete. Corrosion control of launch pad structures relies on the use of coatings selected from the qualified products list (QPL) of the NASA Standard 5008A for Protective Coating of Carbon Steel, Stainless Steel, and Aluminum on Launch Structures, Facilities, and Ground Support Equipment. This standard was developed to establish uniform engineering practices and methods and to ensure the inclusion of essential criteria in the coating of ground support equipment (GSE) and facilities used by or for NASA. This standard is applicable to GSE and facilities that support space vehicle or payload programs or projects and to critical facilities at all NASA locations worldwide. Environmental regulation changes have dramatically reduced the production, handling, use, and availability of conventional protective coatings for application to KSC launch structures and ground support equipment. Current attrition rate of qualified KSC coatings will drastically limit the number of commercial off the shelf (COTS) products available for the Constellation Program (CxP) ground operations (GO). CxP GO identified corrosion detection and control technologies as a critical, initial capability technology need for ground processing of Ares I and Ares V to meet Constellation Architecture Requirements Document (CARD) CxP 70000 operability requirements for reduced ground processing complexity, streamlined integrated testing, and operations phase affordability

  9. Steam generator corrosion 2007; Dampferzeugerkorrosion 2007

    Energy Technology Data Exchange (ETDEWEB)

    Born, M. (ed.)

    2007-07-01

    Between 8th and 9th November, 2007, SAXONIA Standortentwicklungs- und -verwertungsgesellschaft GmbH (Freiberg, Federal Republic of Germany) performed the 3rd Freiberger discussion conference ''Fireside boiler corrosion''. The topics of the lectures are: (a) Steam generator corrosion - an infinite history (Franz W. Alvert); (b) CFD computations for thermal waste treatment plants - a contribution for the damage recognition and remedy (Klaus Goerner, Thomas Klasen); (c) Experiences with the use of corrosion probes (Siegfried R. Horn, Ferdinand Haider, Barbara Waldmann, Ragnar Warnecke); (d) Use of additives for the limitation of the high temperature chlorine corrosion as an option apart from other measures to the corrosion protection (Wolfgang Spiegel); (e) Current research results and aims of research with respect to chlorine corrosion (Ragnar Warnecke); (f) Systematics of the corrosion phenomena - notes for the enterprise and corrosion protection (Thomas Herzog, Wolfgang Spiegel, Werner Schmidl); (g) Corrosion protection by cladding in steam generators of waste incinerators (Joerg Metschke); (h) Corrosion protection and wear protection by means of thermal spraying in steam generators (Dietmar Bendix); (i) Review of thick film nickelized components as an effective protection against high-temperature corrosion (Johann-Wilhelm Ansey); (j) Fireproof materials for waste incinerators - characteristics and profile of requirement (Johannes Imle); (k) Service life-relevant aspects of fireproof linings in the thermal recycling of waste (Till Osthoevener and Wolfgang Kollenberg); (l) Alternatives to the fireproof material in the heating space (Heino Sinn); (m) Cladding: Inconal 625 contra 686 - Fundamentals / applications in boiler construction and plant construction (Wolfgang Hoffmeister); (n) Thin films as efficient corrosion barriers - thermal spray coating in waste incinerators and biomass firing (Ruediger W. Schuelein, Steffen Hoehne, Friedrich

  10. Numerical Study of Corrosion Crack Opening

    DEFF Research Database (Denmark)

    Thoft-Christensen, Palle; Frandsen, Henrik Lund; Svensson, Staffan

    2008-01-01

    for the corrosion crack opening. Experiments and theoretical analysis by a numerical method, FEM, support that the relation between the reduction of the reinforcement bar diameter due to corrosion and the corresponding increase in crack width for a given time interval, measured on the surface of a concrete specimen...... is proportional. More recently, the constant of proportionality, the so-called crack-corrosion index, has been studied further with respect to its dependence on the diameter of the reinforcement and the concrete cover. In the present paper the above-mentioned work is presented and extended with more realistic 3D......-models of the cracked concrete beam. The crack-corrosion index is evaluated for a variation of different parameters, i.e. bar diameter, concrete cover, crack length and type of corrosion product. This paper is an extended version of a paper by Thoft-Christensen et al. (2005) presented at the IFIP WG 7.5 Conference...

  11. Modeling of Corrosion-induced Concrete Damage

    DEFF Research Database (Denmark)

    Thybo, Anna Emilie A.; Michel, Alexander; Stang, Henrik

    2013-01-01

    In the present paper a finite element model is introduced to simulate corrosion-induced damage in concrete. The model takes into account the penetration of corrosion products into the concrete as well as non-uniform formation of corrosion products around the reinforcement. To ac-count for the non......-uniform formation of corrosion products at the concrete/reinforcement interface, a deterministic approach is used. The model gives good estimates of both deformations in the con-crete/reinforcement interface and crack width when compared to experimental data. Further, it is shown that non-uniform deposition...... of corrosion products affects both the time-to cover cracking and the crack width at the concrete surface....

  12. Microencapsulation Technologies for Corrosion Protective Coating Applications

    Science.gov (United States)

    Li, Wenyan; Buhrow, Jerry; Jolley, Scott; Calle, Luz; Pearman, Benjamin; Zhang, Xuejun

    2015-01-01

    Microencapsulation technologies for functional smart Coatings for autonomous corrosion control have been a research area of strong emphasis during the last decade. This work concerns the development of pH sensitive micro-containers (microparticles and microcapsules) for autonomous corrosion control. This paper presents an overview of the state-of-the-art in the field of microencapsulation for corrosion control applications, as well as the technical details of the pH sensitive microcontainer approach, such as selection criteria for corrosion indicators and corrosion inhibitors; the development and optimization of encapsulation methods; function evaluation before and after incorporation of the microcontainers into coatings; and further optimization to improve coating compatibility and performance.

  13. Corrosion protection with eco-friendly inhibitors

    Science.gov (United States)

    Shahid, Muhammad

    2011-12-01

    Corrosion occurs as a result of the interaction of a metal with its environment. The extent of corrosion depends on the type of metal, the existing conditions in the environment and the type of aggressive ions present in the medium. For example, CO3-2 and NO-3 produce an insoluble deposit on the surface of iron, resulting in the isolation of metal and consequent decrease of corrosion. On the other hand, halide ions are adsorbed selectively on the metal surface and prevent formation of the oxide phase on the metal surface, resulting in continuous corrosion. Iron, aluminum and their alloys are widely used, both domestically and industrially. Linear alkylbenzene and linear alkylbenzene sulfonate are commonly used as detergents. They have also been found together in waste water. It is claimed that these chemicals act as inhibitors for stainless steel and aluminum. Release of toxic gases as a result of corrosion in pipelines may lead in certain cases to air pollution and possible health hazards. Therefore, there are two ways to look at the relationship between corrosion and pollution: (i) corrosion of metals and alloys due to environmental pollution and (ii) environmental pollution as a result of corrosion protection. This paper encompasses the two scenarios and possible remedies for various cases, using 'green' inhibitors obtained either from plant extracts or from pharmaceutical compounds. In the present study, the effect of piperacillin sodium as a corrosion inhibitor for mild steel was investigated using a weight-loss method as well as a three-electrode dc electrochemical technique. It was found that the corrosion rate decreased as the concentration of the inhibitor increased up to 9×10-4 M 93% efficiency was exhibited at this concentration.

  14. Traitement des eaux par électrofloculation

    OpenAIRE

    Cansado, Isabel

    1997-01-01

    Traitement des eaux par electrofloculation Les écosystèmes aquatiques sont très affectés par les eaux de rejet qui sont déversées dans les cours d’eau. La charge de ces eaux existe sous diverses formes: solutés, colloïdes ou particules. Il est important de traiter l’eau usée à de faibles coûts au lieu de la rejeter directement dans le milieu récepeteur. Dans le but d’améliorer les procédés physico-chimiques de déstabilisation des émulsions, nous étudions les traitements par électrocoagulat...

  15. Pipeline corrosion prevention by pH stabilization or corrosion inhibitors

    Energy Technology Data Exchange (ETDEWEB)

    Nyborg, Rolf [Institute for Energy Technology, Oslo (Norway)

    2009-07-01

    In many offshore oil and gas projects the pipeline costs are a considerable part of the investment and can become prohibitively high if the corrosivity of the fluid necessitates the use of corrosion resistant alloys instead of carbon steel. Development of more robust and reliable methods for internal corrosion control can increase the application range of carbon steel and therefore have a large economic impact. Corrosion control of carbon steel pipelines has traditionally often been managed by the use of corrosion inhibitors. The pH stabilization technique has been successfully used for corrosion control of several large wet gas pipelines in the last years. This method has advantages over film forming corrosion inhibitors when no or little formation water is produced. The use of corrosion inhibitors in multiphase pipelines implies several challenges which are not fully accounted for in traditional corrosion inhibitor testing procedures. Specialized test procedures have been developed to take account for the presence of emulsions dispersions and sand and clay particles in corrosion inhibitor testing. (author)

  16. 49 CFR 193.2627 - Atmospheric corrosion control.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Atmospheric corrosion control. 193.2627 Section... LIQUEFIED NATURAL GAS FACILITIES: FEDERAL SAFETY STANDARDS Maintenance § 193.2627 Atmospheric corrosion... atmospheric corrosion by— (a) Material that has been designed and selected to resist the corrosive atmosphere...

  17. 49 CFR 193.2631 - Internal corrosion control.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Internal corrosion control. 193.2631 Section 193... GAS FACILITIES: FEDERAL SAFETY STANDARDS Maintenance § 193.2631 Internal corrosion control. Each component that is subject to internal corrosive attack must be protected from internal corrosion by— (a...

  18. 46 CFR 154.412 - Cargo tank corrosion allowance.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Cargo tank corrosion allowance. 154.412 Section 154.412... Containment Systems § 154.412 Cargo tank corrosion allowance. A cargo tank must be designed with a corrosion...) carries a cargo that corrodes the tank material. Note: Corrosion allowance for independent tank type C is...

  19. 49 CFR 192.475 - Internal corrosion control: General.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Internal corrosion control: General. 192.475... Control § 192.475 Internal corrosion control: General. (a) Corrosive gas may not be transported by... taken to minimize internal corrosion. (b) Whenever any pipe is removed from a pipeline for any reason...

  20. 49 CFR 192.461 - External corrosion control: Protective coating.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false External corrosion control: Protective coating... for Corrosion Control § 192.461 External corrosion control: Protective coating. (a) Each external protective coating, whether conductive or insulating, applied for the purpose of external corrosion control...

  1. Atmospheric corrosion of metals in industrial city environment.

    Science.gov (United States)

    Kusmierek, Elzbieta; Chrzescijanska, Ewa

    2015-06-01

    Atmospheric corrosion is a significant problem given destruction of various materials, especially metals. The corrosion investigation in the industrial city environment was carried out during one year exposure. Corrosion potential was determined using the potentiometric method. The highest effect of corrosion processes was observed during the winter season due to increased air pollution. Corrosion of samples pre-treated in tannic acid before the exposure was more difficult compared with the samples without pretreatment. The corrosion products determined with the SEM/EDS method prove that the most corrosive pollutants present in the industrial city air are SO2, CO2, chlorides and dust.

  2. On-line corrosion monitoring in district heating systems

    DEFF Research Database (Denmark)

    Richter, Sonja; Thorarinsdottir, R.I.; Hilbert, Lisbeth Rischel

    2004-01-01

    corrosion monitoring a challenge. Under normal conditions the pH is high (app. 9), conductivity is low (app. 10-200 µS/cm) and the concentration of dissolved oxygen is negligible. The low corrosion rates (in the order of µm/y) are difficult to measure and furthermore, factors such as hydrogen sulphide....... In order to assess both general corrosion and localized corrosion, it is necessary to apply more than one monitoring technique simultaneously, ZRA or EN for measuring localized corrosion and LPR or ER for measuring general corrosion rate. The advantage of monitoring localized corrosion is indisputable...

  3. Mesoporous silica nanoparticles for active corrosion protection.

    Science.gov (United States)

    Borisova, Dimitriya; Möhwald, Helmuth; Shchukin, Dmitry G

    2011-03-22

    This work presents the synthesis of monodisperse, mesoporous silica nanoparticles and their application as nanocontainers loaded with corrosion inhibitor (1H-benzotriazole (BTA)) and embedded in hybrid SiOx/ZrOx sol-gel coating for the corrosion protection of aluminum alloy. The developed porous system of mechanically stable silica nanoparticles exhibits high surface area (∼1000 m2·g(-1)), narrow pore size distribution (d∼3 nm), and large pore volume (∼1 mL·g(-1)). As a result, a sufficiently high uptake and storage of the corrosion inhibitor in the mesoporous nanocontainers was achieved. The successful embedding and homogeneous distribution of the BTA-loaded monodisperse silica nanocontainers in the passive anticorrosive SiOx/ZrOx film improve the wet corrosion resistance of the aluminum alloy AA2024 in 0.1 M sodium chloride solution. The enhanced corrosion protection of this newly developed active system in comparison to the passive sol-gel coating was observed during a simulated corrosion process by the scanning vibrating electrode technique (SVET). These results, as well as the controlled pH-dependent release of BTA from the mesoporous silica nanocontainers without additional polyelectrolyte shell, suggest an inhibitor release triggered by the corrosion process leading to a self-healing effect.

  4. Marine atmospheric corrosion of carbon steels

    Energy Technology Data Exchange (ETDEWEB)

    Morcillo, M.; Alcantara, J.; Diaz, I.; Chico, B.; Simancas, J.; Fuente, D. de la

    2015-07-01

    Basic research on marine atmospheric corrosion of carbon steels is a relatively young scientific field and there continue to be great gaps in this area of knowledge. The presence of akaganeite in the corrosion products that form on steel when it is exposed to marine atmospheres leads to a notable increase in the corrosion rate. This work addresses the following issues: (a) environmental conditions necessary for akaganeite formation; (b) characterisation of akaganeite in the corrosion products formed; (c) corrosion mechanisms of carbon steel in marine atmospheres; (d) exfoliation of rust layers formed in highly aggressive marine atmospheres; (e) long-term corrosion rate prediction; and (f) behaviour of weathering steels. Field research has been carried out at Cabo Vilano wind farm (Camarinas, Galicia) in a wide range of atmospheric salinities and laboratory work involving the use of conventional atmospheric corrosion techniques and near-surface and bulk sensitive analytical techniques: scanning electron microscopy (SEM)/energy dispersive spectrometry (EDS), X-ray diffraction (XRD), Mossbauer spectroscopy and SEM/μRaman spectroscopy. (Author)

  5. Recent Natural Corrosion Inhibitors for Mild Steel: An Overview

    Directory of Open Access Journals (Sweden)

    Marko Chigondo

    2016-01-01

    Full Text Available Traditionally, reduction of corrosion has been managed by various methods including cathodic protection, process control, reduction of the metal impurity content, and application of surface treatment techniques, as well as incorporation of suitable alloys. However, the use of corrosion inhibitors has proven to be the easiest and cheapest method for corrosion protection and prevention in acidic media. These inhibitors slow down the corrosion rate and thus prevent monetary losses due to metallic corrosion on industrial vessels, equipment, or surfaces. Inorganic and organic inhibitors are toxic and costly and thus recent focus has been turned to develop environmentally benign methods for corrosion retardation. Many researchers have recently focused on corrosion prevention methods using green inhibitors for mild steel in acidic solutions to mimic industrial processes. This paper provides an overview of types of corrosion, corrosion process, and mainly recent work done on the application of natural plant extracts as corrosion inhibitors for mild steel.

  6. A STUDY OF CORROSION AND STRESS CORROSION CRACKING OF CARBON STEEL NUCLEAR WASTE STORAGE TANKS

    Energy Technology Data Exchange (ETDEWEB)

    BOOMER, K.D.

    2007-08-21

    The Hanford reservation Tank Farms in Washington State has 177 underground storage tanks that contain approximately 50 million gallons of liquid legacy radioactive waste from cold war plutonium production. These tanks will continue to store waste until it is treated and disposed. These nuclear wastes were converted to highly alkaline pH wastes to protect the carbon steel storage tanks from corrosion. However, the carbon steel is still susceptible to localized corrosion and stress corrosion cracking. The waste chemistry varies from tank to tank, and contains various combinations of hydroxide, nitrate, nitrite, chloride, carbonate, aluminate and other species. The effect of each of these species and any synergistic effects on localized corrosion and stress corrosion cracking of carbon steel have been investigated with electrochemical polarization, slow strain rate, and crack growth rate testing. The effect of solution chemistry, pH, temperature and applied potential are all considered and their role in the corrosion behavior will be discussed.

  7. A Localised Corrosion Cell for Industrial Applications

    DEFF Research Database (Denmark)

    Andersen, A.; Hilbert, Lisbeth Rischel; Jansen, P.

    2003-01-01

    The LOCORR-CELL™ developed by FORCE TECHNOLOGY is an electrochemical cell for industrial applications estimating localised corrosion. The cell is constructed in a carbon steel casing for direct mounting into the system. It is based on an oxygen concentration element reflecting the interaction...... between the environment formed under a deposit or in a crevice. The essential feature of the method is that it reflects the influence of oxygen content, conductivity and temperature as well as the influence of corrosion inhibitors, MIC and other effects that have an effect on localised corrosion under...

  8. Trend on Corrosion Mitigation Research Paper Publication

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Ki Woung [Korea Institute Of Science and Technology Information, Daejeon (Korea, Republic of)

    2016-10-15

    Those papers were analyzed and arranged in the form of publication years and citation, document types, research areas, source titles, countries and languages, organization and funding agencies. In the 'corrosion mitigation' search, the percentage of the publication number of the nuclear science and technology field was about 12%. The sum of the time cited and the average citation number per item in corrosion mitigation survey were 5059 and 11.47, respectively, while those in nuclear corrosion mitigation survey were 285 and 7.5, respectively. Among 38 source titles, the major ones were Nuclear Eng. and Design, Nuclear Sci. and Eng., Intl. J. of Pressure Vessels and Piping.

  9. A 66-kDa protein of bovine hypophyseal Pars tuberalis induces luteinizing hormone release from rat Pars distalis.

    Science.gov (United States)

    Lafarque, Martha; Oliveros, Liliana

    2008-12-01

    In this study, evidence for a factor secreted by bovine hypophyseal pars tuberalis that stimulates luteinizing hormone (LH) release from rat pars distalis cells is shown. The secretion products of bovine pars tuberalis cells into the culture medium were assayed on dispersed rat pars distalis cells in 30 min incubations and superfusion experiments. The culture medium from pars tuberalis total cell populations, added at a dose of 6 microg per tube, induced the greater LH release from pars distalis cells, without effect on follicle stimulating hormone (FSH) release. After pars tuberalis cells separation on a discontinuos Percoll gradient, only the culture medium of cells from 50 and 60% strength Percoll were able to release LH from rat pars distalis cells. Therefore, cell fractions from 50 and 60% strenght Percoll were cultured together. To elicit maximal LH release (6 times the basal output), with the addition of 2 microg of pars tuberalis protein was required, suggesting that these cells produce the factor or factors which affect pars distalis gonadotrope cells. After applying the pars tuberalis culture medium on 12% SDS-PAGE, the band with biological activity was that of 66-kDal. Fifty ng protein of its eluate released almost 9 times the basal output of LH from pars distalis cells. Results suggest a modulating effect of a protein from the bovine pars tuberalis on rat cultured gonadotrope cells from the pars distalis.

  10. Development of a Predictive Corrosion Model Using Locality-Specific Corrosion Indices

    Science.gov (United States)

    2017-09-12

    ER D C/ CE RL T R- 17 -3 1 Integrated Climate Assessment for Army Enterprise Planning Development of a Predictive Corrosion Model Using...Locality-Specific Corrosion Indices Co ns tr uc tio n En gi ne er in g R es ea rc h La bo ra to ry Sean W. Morefield September 2017...Integrated Climate Assessment for Army Enterprise Planning ERDC/CERL TR-17-31 September 2017 Development of a Predictive Corrosion Model Using

  11. The corrosion and corrosion mechanical properties evaluation for the LBB concept in VVERs

    Energy Technology Data Exchange (ETDEWEB)

    Ruscak, M.; Chvatal, P.; Karnik, D.

    1997-04-01

    One of the conditions required for Leak Before Break application is the verification that the influence of corrosion environment on the material of the component can be neglected. Both the general corrosion and/or the initiation and, growth of corrosion-mechanical cracks must not cause the degradation. The primary piping in the VVER nuclear power plant is made from austenitic steels (VVER 440) and low alloy steels protected with the austenitic cladding (VVER 1000). Inspection of the base metal and heterogeneous weldments from the VVER 440 showed that the crack growth rates are below 10 m/s if a low oxygen level is kept in the primary environment. No intergranular cracking was observed in low and high oxygen water after any type of testing, with constant or periodic loading. In the framework of the LBB assessment of the VVER 1000, the corrosion and corrosion mechanical properties were also evaluated. The corrosion and corrosion mechanical testing was oriented predominantly to three types of tests: stress corrosion cracking tests corrosion fatigue tests evaluation of the resistance against corrosion damage. In this paper, the methods used for these tests are described and the materials are compared from the point of view of response on static and periodic mechanical stress on the low alloyed steel 10GN2WA and weld metal exposed in the primary circuit environment. The slow strain rate tests and static loading of both C-rings and CT specimens were performed in order to assess the stress corrosion cracking characteristics. Cyclic loading of CT specimens was done to evaluate the kinetics of the crack growth under periodical loading. Results are shown to illustrate the approaches used. The data obtained were evaluated also from the point of view of comparison of the influence of different structure on the stress corrosion cracking appearance. The results obtained for the base metal and weld metal of the piping are presented here.

  12. Corrosion and alteration of materials from the nuclear industry; La Corrosion et l'alteration des materiaux du nucleaire

    Energy Technology Data Exchange (ETDEWEB)

    Beauvy, M.; Berthoud, G.; Defranceschi, M.; Ducros, G.; Feron, D.; Guerin, Y.; Latge, C.; Limoge, Y.; Madic, C.; Santarini, G.; Seiler, J.M.; Vernaz, E.; Richet, C.

    2010-07-01

    The control of the corrosion phenomenon is of prime importance for the nuclear industry. The efficiency and the safety of facilities can be affected by this phenomenon. The nuclear industry has to face corrosion for a large variety of materials submitted to various environments. Metallic corrosion operates in the hot and aqueous environment of water reactors which represent the most common reactor type in the world. Progresses made in the control of the corrosion of the different components of these reactors allow to improve their safety. Corrosion is present in the facilities of the back-end of the fuel cycle as well (corrosion in acid environment in fuel reprocessing plants, corrosion of waste containers in disposal and storage facilities, etc). The future nuclear systems will widen even more the range of materials to be studied and the situations in which they will be placed (corrosion by liquid metals or by helium impurities). Very often, corrosion looks like a patchwork of particular cases in its description. The encountered corrosion problems and their study are presented in this book according to chapters representing the main sectors of the nuclear industry and classified with respect to their phenomenology. This monograph illustrates the researches in progress and presents some results of particular importance obtained recently. Content: 1 - Introduction: context, stakes and goals; definition of corrosion; a complex science; corrosion in the nuclear industry; 2 - corrosion in water reactors - phenomenology, mechanisms, remedies: A - uniform corrosion: mechanisms, uniform corrosion of fuel cladding, in-situ measurement of generalized corrosion rate by electrochemical methods, uniform corrosion of nickel alloys, characterization of the passive layer and growth mechanisms, the PACTOLE code - an integrating tool, influence of water chemistry on corrosion and contamination, radiolysis impact on uniform corrosion; B - stress corrosion: stress corrosion cracking

  13. Colorimetric visualization of tin corrosion: A method for early stage corrosion detection on printed circuit boards

    DEFF Research Database (Denmark)

    Verdingovas, Vadimas; Jellesen, Morten Stendahl; Ambat, Rajan

    2017-01-01

    circuit board assembly (PCBA) provides a basis for the mechanistic understanding of PCBA corrosion failures and leak current tracks which eventually can lead to electrochemical migration. This paper presents a method for identification of such failures at the early stage of corrosion by using...... a colorimetric tin ion indicator applied as a gel. The examples provided in this paper include visualization of corrosion caused by weak organic acids found in solder fluxes, corrosion profiling on the PCBAs after climatic device level testing, and failure analysis of field returns....

  14. Par-4: A New Activator of Myosin Phosphatase

    Science.gov (United States)

    Vetterkind, Susanne; Lee, Eunhee; Sundberg, Eric; Poythress, Ransom H.; Tao, Terence C.; Preuss, Ute

    2010-01-01

    Myosin phosphatase (MP) is a key regulator of myosin light chain (LC20) phosphorylation, a process essential for motility, apoptosis, and smooth muscle contractility. Although MP inhibition is well studied, little is known about MP activation. We have recently demonstrated that prostate apoptosis response (Par)-4 modulates vascular smooth muscle contractility. Here, we test the hypothesis that Par-4 regulates MP activity directly. We show, by proximity ligation assays, surface plasmon resonance and coimmunoprecipitation, that Par-4 interacts with the targeting subunit of MP, MYPT1. Binding is mediated by the leucine zippers of MYPT1 and Par-4 and reduced by Par-4 phosphorylation. Overexpression of Par-4 leads to increased phosphatase activity of immunoprecipitated MP, whereas small interfering RNA knockdown of endogenous Par-4 significantly decreases MP activity and increases MYPT1 phosphorylation. LC20 phosphorylation assays demonstrate that overexpression of Par-4 reduces LC20 phosphorylation. In contrast, a phosphorylation site mutant, but not wild-type Par-4, interferes with zipper-interacting protein kinase (ZIPK)-mediated MP inhibition. We conclude from our results Par-4 operates through a “padlock” model in which binding of Par-4 to MYPT1 activates MP by blocking access to the inhibitory phosphorylation sites, and inhibitory phosphorylation of MYPT1 by ZIPK requires “unlocking” of Par-4 by phosphorylation and displacement of Par-4 from the MP complex. PMID:20130087

  15. CFD analysis of PAR performance as function of inlet design

    Energy Technology Data Exchange (ETDEWEB)

    Park, Kweonha, E-mail: khpark@kmou.ac.kr [Division of Mechanical and Energy systems Engineering, Korea Maritime University, Dongsam-dong, Yeongdo-gu, Busan 606-791 (Korea, Republic of); Khor, Chong Lee, E-mail: itachi_829@hotmail.com [Department of Mechanical Engineering, Korea Maritime University (Korea, Republic of)

    2016-01-15

    Highlights: • The new concept of PAR (passive autocatalytic recombiner) was proposed and analyzed. • Guidance wall was added at the bottom of PAR to enhance the flow rate through the catalyst. • The new concept of PAR was proved to have a better hydrogen removal performance. - Abstract: Passive autocatalytic recombiner (PAR) is very useful hydrogen mitigation measurement. It is widely implemented in the current and advanced light water reactors (ALWRs). The design of the PARs should be optimized for the specific use under severe accident scenarios. Several techniques and innovations have been fused into the PAR, as an effort to increase its efficiency of hydrogen mitigation. This study proposes different concepts of PAR, which applied some changes to the honeycomb catalyst PAR made by the Korea Nuclear Technology (KNT) Inc. Two slices of plate are added to the bottom of PAR model, which intended to act as a reflection wall and promote the gas flow into PAR. Hydrogen volume fraction was given 4 vol. % which tested by KNT to investigate the performance of PAR in different direction gas flow conditions to see maximum hydrogen recombination rate. The new concept of PAR was proved to have a better hydrogen removal performance compared to the original honeycomb catalyst PAR.

  16. PAR-TERRA directs homologous sex chromosome pairing.

    Science.gov (United States)

    Chu, Hsueh-Ping; Froberg, John E; Kesner, Barry; Oh, Hyun Jung; Ji, Fei; Sadreyev, Ruslan; Pinter, Stefan F; Lee, Jeannie T

    2017-08-01

    In mammals, homologous chromosomes rarely pair outside meiosis. One exception is the X chromosome, which transiently pairs during X-chromosome inactivation (XCI). How two chromosomes find each other in 3D space is not known. Here, we reveal a required interaction between the X-inactivation center (Xic) and the telomere in mouse embryonic stem (ES) cells. The subtelomeric, pseudoautosomal regions (PARs) of the two sex chromosomes (X and Y) also undergo pairing in both female and male cells. PARs transcribe a class of telomeric RNA, dubbed PAR-TERRA, which accounts for a vast majority of all TERRA transcripts. PAR-TERRA binds throughout the genome, including to the PAR and Xic. During X-chromosome pairing, PAR-TERRA anchors the Xic to the PAR, creating a 'tetrad' of pairwise homologous interactions (Xic-Xic, PAR-PAR, and Xic-PAR). Xic pairing occurs within the tetrad. Depleting PAR-TERRA abrogates pairing and blocks initiation of XCI, whereas autosomal PAR-TERRA induces ectopic pairing. We propose a 'constrained diffusion model' in which PAR-TERRA creates an interaction hub to guide Xic homology searching during XCI.

  17. Centromere pairing by a plasmid-encoded type I ParB protein

    DEFF Research Database (Denmark)

    Ringgaard, Simon; Löwe, Jan; Gerdes, Kenn

    2007-01-01

    The par2 locus of Escherichia coli plasmid pB171 encodes two trans-acting proteins, ParA and ParB, and two cis-acting sites, parC1 and parC2, to which ParB binds cooperatively. ParA is related to MinD and oscillates in helical structures and thereby positions ParB/parC-carrying plasmids regularly...

  18. Stress-corrosion cracking in metals

    Science.gov (United States)

    1971-01-01

    Criteria and recommended practices for preventing stress-corrosion cracking from impairing the structural integrity and flightworthiness of space vehicles are presented. The important variables affecting stress-corrosion cracking are considered to be the environment, including time and temperature; metal composition, and structure; and sustained tensile stress. For designing spacecraft structures that are free of stress-corrosion cracking for the service life of the vehicle the following rules apply: (1) identification and control of the environments to which the structure will be exposed during construction, storage, transportation, and use; (2) selection of alloy compositions and tempers which are resistant to stress-corrosion cracking in the identified environment; (3) control of fabrication and other processes which may introduce residual tensile stresses or damage the material; (4) limitation of the combined residual and applied tensile stresses to below the threshold stress level for the onset of cracking throughout the service life of the vehicle; and (5) establishment of a thorough inspection program.

  19. Etchants for Some Corrosion-Resistant Metals

    Science.gov (United States)

    Simmons, J.

    1984-01-01

    Solutions that etch some corrosion-resistant metals described in test report. Etchants selected remove at least 0.4 mil of surface material per hour from nickel alloys, austenitic stainless steel, and annealed titanium alloys, without intergranular attack.

  20. Localized Corrosion of Chromium Coated Steel

    NARCIS (Netherlands)

    Zhang, X.; Beentjes, P.; Mol, A.; Terryn, H.

    2006-01-01

    In this paper, we report on the studies of the local corrosion behaviour of chromium-coated ultra low carbon steel in NaCl solution using polarization, electrochemical impedance spectroscopy (EIS) and SVET.

  1. Erosion–corrosion and corrosion properties of DLC coated low temperature Erosion–corrosion and corrosion properties of DLC coated low temperature

    DEFF Research Database (Denmark)

    Jellesen, Morten Stendahl; Christiansen, Thomas; Hilbert, Lisbeth Rischel

    2009-01-01

    of AISI 316 as substrate for DLC coatings are investigated. Corrosion and erosion–corrosion measurements were carried out on low temperature nitrided stainless steel AISI 316 and on low temperature nitrided stainless steel AISI 316 with a top layer of DLC. The combination of DLC and low temperature...... nitriding dramatically reduces the amount of erosion–corrosion of stainless steel under impingement of particles in a corrosive medium.......Lowtemperature nitriding of stainless steel leads to the formation of a surface zone of so-called expanded austenite, i.e. by dissolution of large amounts of nitrogen in solid solution. In the present work the possibility of using nitrogen expanded austenite “layers” obtained by gaseous nitriding...

  2. Passive, wireless corrosion sensors for transportation infrastructure.

    Science.gov (United States)

    2011-07-01

    Many industrial segments including utilities, manufacturing, government and infrastructure have an urgent need for a means to detect corrosion before significant damage occurs. Transportation infrastructure, such as bridges and roads, rely on reinfor...

  3. Corrosion resistant alloys for reinforced concrete [2009

    Science.gov (United States)

    2009-04-01

    Deterioration of concrete bridges because of reinforcing steel corrosion has been recognized for four-plus decades as a major technical and economic challenge for the United States. As an option for addressing this problem, renewed interest has focus...

  4. Polarized Neutron Reflectometry of Nickel Corrosion Inhibitors.

    Science.gov (United States)

    Wood, Mary H; Welbourn, Rebecca J L; Zarbakhsh, Ali; Gutfreund, Philipp; Clarke, Stuart M

    2015-06-30

    Polarized neutron reflectometry has been used to investigate the detailed adsorption behavior and corrosion inhibition mechanism of two surfactants on a nickel surface under acidic conditions. Both the corrosion of the nickel surface and the structure of the adsorbed surfactant layer could be monitored in situ by the use of different solvent contrasts. Layer thicknesses and roughnesses were evaluated over a range of pH values, showing distinctly the superior corrosion inhibition of one negatively charged surfactant (sodium dodecyl sulfate) compared to a positively charged example (dodecyl trimethylammonium bromide) due to its stronger binding interaction with the surface. It was found that adequate corrosion inhibition occurs at significantly less than full surface coverage.

  5. Study of fluoride corrosion of nickel alloys

    Science.gov (United States)

    Gunther, W. H.; Steindler, M. J.

    1969-01-01

    Report contains the results of an investigation of the corrosion resistance of nickel and nickel alloys exposed to fluorine, uranium hexafluoride, and volatile fission product fluorides at high temperatures. Survey of the unclassified literature on the subject is included.

  6. Corrosion behavior of sensitized duplex stainless steel.

    Science.gov (United States)

    Torres, F J; Panyayong, W; Rogers, W; Velasquez-Plata, D; Oshida, Y; Moore, B K

    1998-01-01

    The present work investigates the corrosion behavior of 2205 duplex stainless steel in 0.9% NaCl solution after various heat-treatments, and compares it to that of 316L austenitic stainless steel. Both stainless steels were heat-treated at 500, 650, and 800 degrees C in air for 1 h, followed by furnace cooling. Each heat-treated sample was examined for their microstructures and Vickers micro-hardness, and subjected to the X-ray diffraction for the phase identification. Using potentiostatic polarization method, each heat-treated sample was corrosion-tested in 37 degrees C 0.9% NaCl solution to estimate its corrosion rate. It was found that simulated sensitization showed an adverse influence on both steels, indicating that corrosion rates increased by increasing the sensitization temperatures.

  7. Corrosion resistance of neodymium and dysprosium hydrides

    Science.gov (United States)

    Karakchieva, Natalia; Lyamina, Galina; Knyazeva, Elena; Sachkov, Victor; Kurzina, Irina; Pichugina, Alina; Vladimirov, Alexander; Kazantseva, Ludmila; Sachkova, Anna

    2017-11-01

    This paper describes the methods of obtaining hydrides of rare earth elements such as dysprosium and neodymium. The properties and corrosion resistance of these elements are investigated. A synthesis method of monophasic dysprosium and neodymium dihydrides is presented. Synthesized dihydrides are agglomerates with an average size of 3-50 µm and are formed by crystalline grains of a nanometer size. BET specific surface area, morphology, elemental analyses and composition of samples have been studied. Corrosion stability in aqueous solutions of hydrochloric acid and sodium hydroxide were studied. It was determined that both hydrides undergo hydrolysis in acid and alkaline mediums. Neodymium hydride is more stable to corrosion than dysprosium hydride, which is proved by its longer exposure to aggressive medium to hydrides. The formation of insoluble /poorly soluble products of corrosion can make a significant contribution to the process of powder dissolution.

  8. Optimal Corrosion Control Treatment Evaluation Technical Recommendations

    Science.gov (United States)

    This document provides technical recommendations that both systems and primacy agencies can use to comply with LCR CCT requirements and effective evaluation and designation of optimal corrosion control treatment (OCCT).

  9. Crevice corrosion products of dental amalgam

    Energy Technology Data Exchange (ETDEWEB)

    Sutow, E.J.; Jones, D.W.; Hall, G.C.; Owen, C.G. (Division of Dental Biomaterials Science, Faculty of Dentistry, Dalhousie University, Halifax, Nova Scotia (Canada))

    1991-07-01

    The objective of this study was to determine the in vitro corrosion products that resulted from crevice corrosion of low- and high-copper dental amalgams. Specimens were potentiostatically polarized in a chloride-containing electrolyte while set against a PTFE surface to form a crevice. After 16 h, corrosion products were examined by light microscopy, SEM, EDS, and XRD. Analysis showed the presence of three previously reported products (Sn4(OH)6Cl2, SnO, and Cu2O) and a new product, CuCl, which formed on high-copper, {gamma} 2-free amalgams. Thermodynamic considerations show that CuCl is stable for the reported in vivo potentials of amalgam restorations and the high acidity and high chloride ion concentration associated with crevice corrosion.

  10. SAFARI 2000 PAR Measurements, Kalahari Transect, Botswana, Wet Season 2000

    Data.gov (United States)

    National Aeronautics and Space Administration — ABSTRACT: Ceptometer data from a Decagon AccuPAR (Model PAR-80) were collected at four sites in Botswana during the SAFARI 2000 Kalahari Transect Wet Season Campaign...

  11. SAFARI 2000 PAR Measurements, Kalahari Transect, Botswana, Wet Season 2000

    Data.gov (United States)

    National Aeronautics and Space Administration — Ceptometer data from a Decagon AccuPAR (Model PAR-80) were collected at four sites in Botswana during the SAFARI 2000 Kalahari Transect Wet Season Campaign (March,...

  12. Emerging Nanotechnology-based Corrosion Control Coatings

    Science.gov (United States)

    2009-02-01

    Al2O3, Fe3O4, Ce (NO3)3, etc. wang Y., et al, Wear, 260, 976-983, 2006. • Epoxy systems with dispersed polyaniline nanoparticles Wessling, B and...triglyceride plus corrosion inhibitor. Koene, B., et al, Proc. Self-healing Conf. 2007 Phenolic varnish plus corrosion inhibitors Stephenson, L, et al US...interactions of nano-sized chemicals Increased surface-to-volume ratio of nanoparticles may result in: -Ingestion through cell membrane -Sensitivity to

  13. A technique for predicting steel corrosion resistance

    Science.gov (United States)

    Novikov, V. F.; Sokolov, R. A.; Neradovskiy, D. F.; Muratov, K. R.

    2018-01-01

    Research works were carried out to develop a technique with the aim to increase the lifetime of steel items used in corrosive media. The possibility to monitor corrosion parameters of steel samples is analyzed on the basis of magnetic properties obtained by means of a magnetic structuroscope DIUS-1.15M designed by the Institute of Metal Physics of the Ural Branch of the Russian Academy of Sciences (IMP UB RAS).

  14. Corrosion sealing of amalgam restorations in vitro.

    Science.gov (United States)

    Mahler, David B; Pham, Bao V; Adey, Jerry D

    2009-01-01

    Amalgam restorations, when first placed, have been shown to exhibit a gap at the amalgam/tooth interface. With time in service, this gap fills with corrosion products that have the potential to "seal" the restoration. With the advent of high-copper, more corrosion-resistant amalgams, there has been concern that the time required to create this seal would be increased significantly when compared with low-copper traditional amalgams. The current study was designed to address this concern. Amalgam was condensed into a MACOR mold, simulating a Class I cavity form and then immersed into a 1.0% NaCl solution to simulate oral conditions. Using an air pressure test, the sealing was monitored over time. The results showed that the sealing was influenced by the size of the initial gap prior to immersion as well as corrosion resistance of the amalgam and that a corrosion-resistant amalgam with a small initial gap size can seal as quickly as a corrosion-prone amalgam. Therefore, it is not possible to predict sealing behavior based on corrosion resistance, alone. Furthermore, the presence of zinc in the amalgam alloy has been shown to result in the formation of zinc corrosion products in the amalgam/mold margin, which contributes to more rapid sealing. Analysis of a tooth extracted after 16 years of clinical service that had been restored with an amalgam-containing zinc was also shown to contain zinc corrosion products in the occlusal marginal area. This could explain the reported reduction in marginal fracture of clinically placed amalgam restorations made from zinc-containing alloys.

  15. Ant nest corrosion -- Exploring the labyrinth

    Energy Technology Data Exchange (ETDEWEB)

    Elliott, P.; Corbett, R.A.

    1999-07-01

    The phenomenon of ant nest (formicary) corrosion is reviewed. Current theories indicate that attack requires the simultaneous presence of moisture, oxygen and a corrodent, usually an organic acid, such as formic acid. Morphological features are presented using several recent case studies as examples. This paper seeks to create more answers to this less appreciated phenomenon that causes premature corrosion failure in copper tubes used typically for refrigeration or air conditioning applications.

  16. Microbiologically Influenced Corrosion in Military Environments

    Science.gov (United States)

    2006-01-01

    Others t Ref 12) studied direct microbial detra- ,- dation of coatings. such as Buna-N (a polymer of acrylonitrile and hutadiene: polyurethane (a...estuanne. and , production. Progressive changes in the for- marine waters. During stagnation. naturalls .W imulations of lubricatitng oils hawe introduced...Corrpsion in Specific Environments due to their corrosion resistance. antifouling attack where chlorides penetrate the passive film corrosion potential and

  17. A Combined Global and Local Approach to Elucidate Spatial Organization of the Mycobacterial ParB-parS Partition

    Energy Technology Data Exchange (ETDEWEB)

    Chaudhuri, Barnali [University of Buffalo, The State University of New York; Gupta, Sayan [Case Western Reserve University; Urban, Volker S [ORNL; Chance, Mark [Case Western Reserve University; D' Mello, Rhijuta [Case Western Reserve University; Smith, Lauren [University of Buffalo, The State University of New York; Lyons, Kelly [University of Buffalo, The State University of New York; Gee, Jessica [University of Buffalo, The State University of New York

    2010-01-01

    Combining diverse sets of data at global (size, shape) and local (residue) scales is an emerging trend for elucidating the organization and function of the cellular assemblies. We used such a strategy, combining data from X-ray and neutron scattering with H/D-contrast variation and X-ray footprinting with mass spectrometry, to elucidate the spatial organization of the ParB-parS assembly from Mycobacterium tuberculosis. The ParB-parS participates in plasmid and chromosome segregation and condensation in predivisional bacterial cells. ParB polymerizes around the parS centromere(s) to form a higher-order assembly that serves to recruit cyto-skeletal ParA ATPases and SMC proteins for chromosome segregation. A hybrid model of the ParB-parS was built by combining and correlating computational models with experiment-derived information about size, shape, position of the symmetry axis within the shape, internal topology, DNA-protein interface, exposed surface patches, and prior knowledge. This first view of the ParB-parS leads us to propose how ParB spread on the chromosome to form a larger assembly.

  18. A Combined Global and Local Approach to Elucidate Spatial Organization of the Mycobacterial ParB-parS Partition Assembly

    Energy Technology Data Exchange (ETDEWEB)

    B Chaudhuri; S Gupta; V Urban; M Chance; R DMello; L Smith; K Lyons; J Gee

    2011-12-31

    Combining diverse sets of data at global (size, shape) and local (residue) scales is an emerging trend for elucidating the organization and function of the cellular assemblies. We used such a strategy, combining data from X-ray and neutron scattering with H/D-contrast variation and X-ray footprinting with mass spectrometry, to elucidate the spatial organization of the ParB-parS assembly from Mycobacterium tuberculosis. The ParB-parS participates in plasmid and chromosome segregation and condensation in predivisional bacterial cells. ParB polymerizes around the parS centromere(s) to form a higher-order assembly that serves to recruit cyto-skeletal ParA ATPases and SMC proteins for chromosome segregation. A hybrid model of the ParB-parS was built by combining and correlating computational models with experiment-derived information about size, shape, position of the symmetry axis within the shape, internal topology, DNA-protein interface, exposed surface patches, and prior knowledge. This first view of the ParB-parS leads us to propose how ParB spread on the chromosome to form a larger assembly.

  19. Silica nanocontainers for active corrosion protection.

    Science.gov (United States)

    Maia, Frederico; Tedim, João; Lisenkov, Aleksey D; Salak, Andrei N; Zheludkevich, Mikhail L; Ferreira, Mário G S

    2012-02-21

    Novel self-healing protective coatings with nanocontainers of corrosion inhibitors open new opportunities for long-term anticorrosion protection of different metallic materials. In this paper a new type of functional nanoreservoir based on silica nanocapsules (SiNC) synthesized and loaded with corrosion inhibitor 2-mercaptobenzothiazole (MBT) in a one-stage process is reported for the first time. Unlike conventional mesoporous silica nanoparticles, SiNC possess an empty core and shell with gradual mesoporosity, arising from the particular conditions of the synthetic route adopted, which confers significant loading capacity and allows prolonged and stimuli-triggered release of the inhibiting species. The kinetics of inhibitor release was studied at different pH values and concentrations of NaCl. The results show a clear dependence of the release profiles on corrosion relevant triggers such as pH and Cl(-) concentration. When SiNC loaded with MBT are dispersed in NaCl solution, there is a significant decrease of the corrosion activity on aluminium alloy 2024. More importantly, when SiNC-MBT is added to a conventional water-based coating formulation, the modified coating hampers corrosion activity at the metal interface, better than in the case of direct addition of corrosion inhibitor. Furthermore, self-healing is observed before and after artificially inflicting defects in the modified coatings. As a result, the developed nanocontainers show high potential to be used in new generation of active protective coatings. This journal is © The Royal Society of Chemistry 2012

  20. Host response biomarker in sepsis: suPAR detection.

    Science.gov (United States)

    Giamarellos-Bourboulis, Evangelos J; Georgitsi, Marianna

    2015-01-01

    Recent studies of our group have shown that suPAR may complement APACHE II score for risk assessment in sepsis. suPAR may be measured in serum of patients by an enzyme immunosorbent assay developed by Virogates (suPARnostic™). Production of suPAR from circulating neutrophils and monocytes may be assessed after isolation of neutrophils and monocytes and ex vivo culture. This is followed by measurement of suPAR in culture supernatants.

  1. Recent Developments on Autonomous Corrosion Protection Through Encapsulation

    Science.gov (United States)

    Li, W.; Buhrow, J. W.; Calle, L. M.; Gillis, M.; Blanton, M.; Hanna, J.; Rawlins, J.

    2015-01-01

    This paper concerns recent progress in the development of a multifunctional smart coating, based on microencapsulation, for the autonomous detection and control of corrosion. Microencapsulation has been validated and optimized to incorporate desired corrosion control functionalities, such as early corrosion detection and inhibition, through corrosion-initiated release of corrosion indicators and inhibitors, as well as self-healing agent release triggered by mechanical damage. While proof-of-concept results have been previously reported, more recent research and development efforts have concentrated on improving coating compatibility and synthesis procedure scalability, with a targeted goal of obtaining easily dispersible pigment-grade type microencapsulated materials. The recent progress has resulted in the development of pH-sensitive microparticles as a corrosion-triggered delivery system for corrosion indicators and inhibitors. The synthesis and early corrosion indication results obtained with coating formulations that incorporate these microparticles are reported. The early corrosion indicating results were obtained with color changing and with fluorescent indicators.

  2. Corrosion behaviour of non-ferrous metals in sea water

    Energy Technology Data Exchange (ETDEWEB)

    Birn, Jerzy; Skalski, Igor [Ship Design and Research Centre, Al. Rzeczypospolitej 8, 80-369 Gdansk (Poland)

    2004-07-01

    The most typical kinds of corrosion of brasses are selective corrosion (dezincification) and stress corrosion. Prevention against these kinds of corrosion lies in application of arsenic alloy addition and appropriate heat treatment removing internal stresses as well as in maintaining the arsenic and phosphorus contents on a proper level. The most typical corrosion of cupronickels is the local corrosion. Selective corrosion occurs less often and corrosion cracking caused by stress corrosion in sea water does not usually occur. Crevice corrosion is found especially in places of an heterogeneous oxidation of the surface under inorganic deposits or under bio-film. Common corrosive phenomena for brasses and cupronickels are the effects caused by sea water flow and most often the impingement attack. Alloy additions improve resistance to the action of intensive sea water flow but situation in this field requires further improvement, especially if the cheaper kinds of alloys are concerned. Contaminants of sea water such as ammonia and hydrogen sulphide are also the cause of common corrosion processes for all copper alloys. Corrosion of copper alloys may be caused also by sulphate reducing bacteria (SRB). Galvanic corrosion caused by a contact with titanium alloys e.g. in plate heat exchangers may cause corrosion of both kinds copper alloys. Bronzes belong to copper alloys of the highest corrosion resistance. Failures that sometimes occur are caused most often by the cavitation erosion, by an incorrect chemical composition of alloys or at last by their inadequate structure. The main problems of aluminium alloys service in sea water are following phenomena: local corrosion (pitting and crevice corrosion), galvanic corrosion, exfoliation and corrosion in the presence of OH- ions. The cause of local corrosion are caused by presence of passive film on the alloy's surface and presence of chlorides in sea water which are able to damage the passive film. Galvanic corrosion is

  3. Long-term Corrosion of Copper Container in Bentonite Buffer

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Min Soo; Choi, Jong Won; Choi, Heui Joo; Lee, Jong Youl; Jeong, Jong Tae; Kim, Sung Ki; Cho, Dong Keun

    2007-05-15

    The experimental method for the evaluation of copper corrosion was discussed in this report. Especially, the corrosion behavior of a copper container in a compacted bentonite environment was reviewed in detail. Several previous studies on the copper corrosion in a bentonite environment were summarized and the applied methods were illustrated firstly. On the basis of the review, it is discussed how to execute long-term copper corrosion test as regarding korean disposal environment. The selection of bentonite medium and the composition of a medium such as bentonite-sand mixture or bentonite-sand double layer was mentioned in this report. The need for protection layer on copper surface was also discussed for reducing initial copper corrosion rate. As key aspects on the corrosion test, a measuring of corrosion rate, an observation of surface morphology, an analysis of corrosion product, and a measuring of corrosion potential were pointed out. For the purpose of a experimental consistency, the necessity of standard composition for a bentonite and a underground water might be confirmed before the test. Consequently, three experimental designs were derived for the corrosion test such as a corrosion testing design at creep condition, a simple corrosion design for the evaluation for other candidate materials, and lastly, a corrosion testing design in compacted bentonite. Through this survey and discussion for a copper corrosion in bentonite environment it would be very helpful for a high level radioactive waste disposal plan in the future.

  4. Copenhagen uPAR prostate cancer (CuPCa) database

    DEFF Research Database (Denmark)

    Lippert, Solvej; Berg, Kasper D; Høyer-Hansen, Gunilla

    2016-01-01

    AIM: Urokinase plasminogen activator receptor (uPAR) plays a central role during cancer invasion by facilitating pericellular proteolysis. We initiated the prospective 'Copenhagen uPAR Prostate Cancer' study to investigate the significance of uPAR levels in prostate cancer (PCa) patients. METHODS...

  5. Les Brulures Chimiques Par Le Laurier Rose

    Science.gov (United States)

    Bakkali, H.; Ababou, M.; Nassim Sabah, T.; Moussaoui, A.; Ennouhi, A.; Fouadi, F.Z.; Siah, S.; Ihrai, H.

    2010-01-01

    Summary Le laurier rose ou Nerium oleander est un arbuste qui pousse naturellement dans les régions méditerranéennes. Au Maroc on le trouve dans les lieux humides. Il est réputé par ses risques de toxicité systémique en cas d'empoisonnement à cause de la présence de deux alcaloïdes, surtout l'oléandrine. La littérature illustre des cas d'utilisation locale des feuilles de cette plante contre la gale, les hémorroïdes et les furoncles. Nous rapportons deux cas de brûlures chimiques par le laurier rose de gravité différente. Cela doit aboutir à une information élargie de la population, ainsi qu'une réglementation stricte de sa commercialisation. PMID:21991211

  6. Les Brulures Chimiques Par Le Laurier Rose

    OpenAIRE

    Bakkali, H.; Ababou, M.; Nassim Sabah, T.; Moussaoui, A.; Ennouhi, A.; Fouadi, F.Z.; Siah, S.; Ihrai, H.

    2010-01-01

    Le laurier rose ou Nerium oleander est un arbuste qui pousse naturellement dans les régions méditerranéennes. Au Maroc on le trouve dans les lieux humides. Il est réputé par ses risques de toxicité systémique en cas d'empoisonnement à cause de la présence de deux alcaloïdes, surtout l'oléandrine. La littérature illustre des cas d'utilisation locale des feuilles de cette plante contre la gale, les hémorroïdes et les furoncles. Nous rapportons deux cas de brûlures chimiques par le laurier rose ...

  7. Deltagerinvolveret organisationsudvikling med PAR som metode

    DEFF Research Database (Denmark)

    Sparre, Mogens

    2017-01-01

    resistant to change. The quite widespread narrative of resistance to change, is believed to originate from the many top-down driven change projects implemented by the top management or/and external consultants. Is it possible to create a desired change in the form of the inter-subjective perception building......When a leader wants to initiate or influence some necessary changes in the organization, he must be aware of the fact that the subjects that form the organization create their own meaning about actions the manager wants implemented. This article confronts the assumption that people are by nature...... about the organization in an management group with a Participatory Action Research (PAR) case study? The article deals with a Phenomenological case study, where the researcher, with a PAR approach method, creates a research design with the purpose to influence the participant’s “Subjective perception...

  8. [Ambroise Paré in French literature].

    Science.gov (United States)

    Dumaitre, P

    1995-01-01

    The 16th century by its passionate side has been the favourite one of authors of historical novels in which among the heroes of "cloak and dagger stories" appears sometime Ambroise Paré. Alexandre Dumas (the father) has shown him at the court of Charles IX in La Reine Margot (1845) where he does not however play a great role. On the contrary, Balzac in Le Martyr calviniste (1842) has given him a capital part close to the dying François II, whom he intended to trepanize but had to give up this idea as a consequence of the opposition of the queen-mother Catherine de Médicis. In the present century, Robert Merle in Paris ma bonne ville (Fortune de France, 3, 1980) shows Paré at the time of the Saint Barthélemy.

  9. Exposure testing of fasteners in preservative treated wood : gravimetric corrosion rates and corrosion product analyses

    Science.gov (United States)

    Samuel L. Zelinka; Rebecca J. Sichel; Donald S. Stone

    2010-01-01

    Research was conducted to determine the corrosion rates of metals in preservative treated wood and also understand the mechanism of metal corrosion in treated wood. Steel and hot-dip galvanized steel fasteners were embedded in wood treated with one of six preservative treatments and exposed to 27oC at 100% relative humidity for 1 year. The...

  10. NASA's Beachside Corrosion Test Site and Current Environmentally Friendly Corrosion Control Initiatives

    Science.gov (United States)

    Russell, Richard W.; Calle, Luz Marina; Johnston, Frederick; Montgomery, Eliza L.; Curran, Jerome P.; Kolody, Mark R.

    2013-01-01

    NASA began corrosion studies at the Kennedy Space Center (KSC) in 1966 during the Gemini/Apollo Programs with the evaluation of long-term corrosion protective coatings for carbon steel. KSC's Beachside Corrosion Test Site (BCTS), which has been documented by the American Society of Materials (ASM) as one of the most corrosive, naturally occurring, environments in the world, was established at that time. With the introduction of the Space Shuttle in 1981, the already highly corrosive conditions at the launch pad were rendered even more severe by the acid ic exhaust from the solid rocket boosters. In the years that followed, numerous studies have identified materials, coatings, and maintenance procedures for launch hardware and equipment exposed to the highly corrosive environment at the launch pad. This paper presents a historical overview of over 45 years of corrosion and coating evaluation studies and a description of the BCTS's current capabilities. Additionally, current research and testing programs involving chromium free coatings, environmentally friendly corrosion preventative compounds, and alternates to nitric acid passivation will be discussed.

  11. Initiation and inhibition of pitting corrosion on reinforcing steel under natural corrosion conditions

    Energy Technology Data Exchange (ETDEWEB)

    Abd El Wanees, S., E-mail: s_wanees@yahoo.com [Chemistry Department, Faculty of Science, University of Tabuk, Tabuk (Saudi Arabia); Chemistry Department, Faculty of Science, Zagazig University, Zagazig 44519 (Egypt); Bahgat Radwan, A. [Center for Advanced Materials, Qatar University, Doha 2713 (Qatar); Alsharif, M.A. [Chemistry Department, Faculty of Science, University of Tabuk, Tabuk (Saudi Arabia); Abd El Haleem, S.M. [Chemistry Department, Faculty of Science, Zagazig University, Zagazig 44519 (Egypt)

    2017-04-01

    Initiation and inhibition of pitting corrosion on reinforcing steel in saturated, naturally aerated Ca(OH){sub 2} solutions, under natural corrosion conditions, are followed through measurements of corrosion current, electrochemical impedance spectroscopy and SEM investigation. Induction period for pit initiation and limiting corrosion current for pit propagation are found to depend on aggressive salt anion and cation-types, as well as, concentration. Ammonium chlorides and sulfates are more corrosive than the corresponding sodium salts. Benzotriazole and two of its derivatives are found to be good inhibitors for pitting corrosion of reinforcing steel. Adsorption of these compounds follows a Langmuir adsorption isotherm. The thermodynamic functions ΔE{sup ∗}, ΔH{sup ∗} and ΔS{sup ∗} for pitting corrosion processes in the absence and presence of inhibitor are calculated and discussed. - Highlights: • Cl{sup −} and SO{sub 4} {sup 2-} induce pitting corrosion on passive reinforcing steel. • Initiation and propagation of pitting depend on cation and anion types. • Inhibition is based on adsorption according to Langmuir isotherm.

  12. A study of microbial population dynamics associated with corrosion rates influenced by corrosion control materials

    NARCIS (Netherlands)

    Chang, Yu Jie; Hung, Chun Hsiung; Lee, Jyh Wei; Chang, Yi Tang; Lin, Fen Yu; Chuang, Chun Jie

    2015-01-01

    This research aims to analyze the variations of microbial community structure under anaerobic corrosive conditions, using molecular fingerprinting method. The effect of adding various materials to the environment on the corrosion mechanism has been discussed. In the initial experiment,

  13. Etude par imagerie radar des pollutions pétrolières

    Directory of Open Access Journals (Sweden)

    G. Rees

    2004-06-01

    Full Text Available En Russie, chaque année, les déversements de pétrole représentent un cinquième de la production totale. Les plus importants se produisent dans le domaine périglaciaire où le milieu naturel est d’une extrême fragilité. Les pipelines sont soumis à de rudes conditions notamment à la corrosion et aux processus cryogéniques. Le risque de rupture augmente en conséquence. La surveillance des déversements d’hydrocarbures, contrainte par l’immensité et la fréquente inaccessibilité du réseau de pipelines, peut être réalisée par le recours à la télédétection. L’objectif de ce travail est de fournir, à travers l’exemple de la catastrophe d’Usinsk (Rép. de Komi survenue en 1994, des outils d’analyse des images radar. Outre leur capacité à s’affranchir du couvert nuageux, les capteurs radar apportent des informations complémentaires à celles fournies par des capteurs optiques. L’exploitation thématique de ces images est rendue difficile par un certain nombre de facteurs perturbateurs tels que les caractéristiques propres du capteur, la direction de visée, la topographie et le phénomène de chatoiement (speckle. Le travail présenté montre le rôle prépondérant joué par ces corrections qui permettent de disposer de données quantitatives comparables d’une date à une autre. La méthode mise au point ici pour le suivi temporel de l’épanchement de pétrole d’Usinsk à partir de trois images radar, est discutée notamment dans ses limites et son aspect opérationnel possible.

  14. étude par AFM dynamique.

    African Journals Online (AJOL)

    user

    Ces forces oscillatoires de solvatation sont carac- térisées par une augmentation en amplitude lorsque la distance de confinement diminue (en tendant vers zéro), la périodicité des oscillations étant approximativement égales au diamètre des molécules du liquide confiné. Dans ce travail, nous sommes partis des récents ...

  15. Corrosion and Protection of Metal in the Seawater Desalination

    Science.gov (United States)

    Hou, Xiangyu; Gao, Lili; Cui, Zhendong; Yin, Jianhua

    2018-01-01

    Seawater desalination develops rapid for it can solve water scarcity efficiently. However, corrosion problem in the seawater desalination system is more serious than that in normal water. So, it is important to pay attention to the corrosion and protection of metal in seawater desalination. The corrosion characteristics and corrosion types of metal in the seawater desalination system are introduced in this paper; In addition, corrosion protect methods and main influencing factors are stated, the latest new technologies about anti-corrosion with quantum energy assisted and magnetic inhibitor are presented.

  16. Corrosion Behavior of Brass In Tio2 Nanofluids

    Science.gov (United States)

    Wu, Kai; Ge, Hong-Hua; Wang, Feng; Zhou, Hong-Wang

    2017-09-01

    Corrosion behavior of brass electrode in TiO2 nanofluids was analyzed using electrochemical impedance spectroscopy. The experimental results show that TiO2 nanoparticles promote corrosion of brass. The corrosion resistance of brass electrode decreases with the increase of the temperature of the TiO2 nanofluids. Sodium dodecyl benzene sulfonate (SDBS) is a dispersant in nanofluids and also appears corrosion inhibition to brass, and the corrosion inhibition enhances with the increase of SDBS concentration. The corrosion resistance of brass in TiO2 nanofluids would decrease when the concentration of dispersant SDBS exceeds a certain value.

  17. Proteinase-activated receptors (PARs) as targets for antiplatelet therapy.

    Science.gov (United States)

    Cunningham, Margaret; McIntosh, Kathryn; Bushell, Trevor; Sloan, Graeme; Plevin, Robin

    2016-04-15

    Since the identification of the proteinase-activated receptor (PAR) family as mediators of serine protease activity in the 1990s, there has been tremendous progress in the elucidation of their pathophysiological roles. The development of drugs that target PARs has been the focus of many laboratories for the potential treatment of thrombosis, cancer and other inflammatory diseases. Understanding the mechanisms of PAR activation and G protein signalling pathways evoked in response to the growing list of endogenous proteases has yielded great insight into receptor regulation at the molecular level. This has led to the development of new selective modulators of PAR activity, particularly PAR1. The mixed success of targeting PARs has been best exemplified in the context of inhibiting PAR1 as a new antiplatelet therapy. The development of the competitive PAR1 antagonist, vorapaxar (Zontivity), has clearly shown the value in targeting PAR1 in acute coronary syndrome (ACS); however the severity of associated bleeding with this drug has limited its use in the clinic. Due to the efficacy of thrombin acting via PAR1, strategies to selectively inhibit specific PAR1-mediated G protein signalling pathways or to target the second thrombin platelet receptor, PAR4, are being devised. The rationale behind these alternative approaches is to bias downstream thrombin activity via PARs to allow for inhibition of pro-thrombotic pathways but maintain other pathways that may preserve haemostatic balance and improve bleeding profiles for widespread clinical use. This review summarizes the structural determinants that regulate PARs and the modulators of PAR activity developed to date. © 2016 Authors; published by Portland Press Limited.

  18. High temperature corrosion during biomass firing: improved understanding by depth resolved characterisation of corrosion products

    DEFF Research Database (Denmark)

    Okoro, Sunday Chukwudi; Montgomery, Melanie; Jappe Frandsen, Flemming

    2015-01-01

    The high temperature corrosion of an austenitic stainless steel (TP 347H FG), widely utilised as a superheater tube material in Danish power stations, was investigated to verify the corrosion mechanisms related to biomass firing. KCl coated samples were exposed isothermally to 560 degrees C...... changes within the near surface region (covering both the deposit and the steel surface). Such cross-section analysis was further complemented by plan view investigations (additionally involving X-ray diffraction) combined with removal of the corrosion products. Improved insights into the nature...... of the corrosion products as a function of distance from the deposit surface were revealed through this comprehensive characterisation. Corrosion attack during simulated straw-firing conditions was observed to occur through both active oxidation and sulphidation mechanisms....

  19. Screening of soil corrosivity by field testing: Results and design of an electrochemical soil corrosion probe

    DEFF Research Database (Denmark)

    Nielsen, Lars vendelbo; Bruun, Niels Kåre

    1996-01-01

    The corrosivity of different types of soil have been assessed by exposing carbon-steel plates at 50 different locations in Denmark for an extended period of time. The investigations included weight loss measurements and analysis of the chemical compositions of the corrosion products formed...... on the plates during exposure. An electrochemical soil corrosion probe has been designed and manufactured allowing for simultaneous measurements of several qauntities to predict corrosion. The probe consists of individual sections capable of measuring redox-potential, corrosion potential, soil resistivity...... and hydrogen absorption rates. In addition, traditional carbon-steel 3-electrode arrangements allow for performance of any kind of electrochemical meaurement (EIS, polarisation curves, LPR-measurements, galvanostatic pulse etc.)....

  20. Prediction of corrosion rates of water distribution pipelines according to aggressive corrosive water in Korea.

    Science.gov (United States)

    Chung, W S; Yu, M J; Lee, H D

    2004-01-01

    The drinking water network serving Korea has been used for almost 100 years. Therefore, pipelines have suffered various degrees of deterioration due to aggressive environments. The pipe breaks were caused by in-external corrosion, water hammer, surface loading, etc. In this paper, we focused on describing corrosion status in water distribution pipes in Korea and reviewing some methods to predict corrosion rates. Results indicate that corrosive water of lakes was more aggressive than river water and the winter was more aggressive compared to other seasons. The roughness growth rates of Dongbok lake showed 0.23 mm/year. The high variation of corrosion rates is controlled by the aging pipes and smaller diameter. Also the phenolphthalein test on a cementitious core of cement mortar lined ductile cast iron pipe indicated the pipes over 15 years old had lost 50-100% of their lime active cross sectional area.

  1. Long Term Corrosion Potential and Corrosion Rate of Creviced Alloy 22 in Chloride Plus Nitrate Brines

    Energy Technology Data Exchange (ETDEWEB)

    Evans, K J; Stuart, M L; Etien, R A; Hust, G A; Estill, J C; Rebak, R B

    2005-11-05

    Alloy 22 is a nickel base alloy highly resistant to all forms of corrosion. In conditions where tight crevices exist in hot chloride containing solutions and at anodic potentials, Alloy 22 may suffer crevice corrosion, a form of localized attack. The occurrence (or not) of crevice corrosion in a given environment (e.g. salt concentration and temperature), is governed by the values of the critical potential (E{sub crit}) for crevice corrosion and the corrosion potential (E{sub corr}) that the alloy may establish in the studied environment. If E{sub corr} is equal or higher than E{sub crit}, crevice corrosion may be expected. In addition, it is generally accepted that as Alloy 22 becomes passive in a certain environment, its E{sub corr} increases and its corrosion rate (CR) decreases. This paper discusses the evolution of E{sub corr} and corrosion rate (CR) of creviced Alloy 22 specimens in six different mixtures of sodium chloride (NaCl) and potassium nitrate (KNO{sub 3}) at 100 C. The effect of immersion time on the value of E{sub crit} was also determined. Two types of specimens were used, polished as-welded (ASW) and as-welded plus solution heat-treated (ASW+SHT). The latter contained the black annealing oxide film on the surface. Results show that, as the immersion time increases, E{sub corr} increased and the CR decreased. Even for highly concentrated brine solutions at 100 C the CR was < 30 nm/year after more than 250 days immersion. Some of the exposed specimens (mainly the SHT specimens) suffered crevice corrosion at the open circuit potential in the naturally aerated brines. Immersion times of over 250 days did not reduce the resistance of Alloy 22 to localized corrosion.

  2. RESEARCH OF FRUIT CONSERVES’ CORROSIVE AGGRESSIVENESS

    Directory of Open Access Journals (Sweden)

    I. Kuznecova

    2017-10-01

    Full Text Available Corrosion of metal canning containers is one of the obstacles in spreading its application for packing of food. Particularly aggressive to the metal container is fruit canned medium, containing organic acids.The basic material for the production of metal canning container is white tinplate. The main advantage of white tinplate is the tin compounds are harmless to human organism. For this reason, a white badge is used widely, usually used for production of canning containers, packaging beverages. Despite the fact that recently often used containers made of aluminum badge (foil, the basic material for manufacturing metal canning containers is steel white tinplate.Now applied for coating paints and varnishes do not provide anti-corrosion protection of inner surface of metal containers during storage. Preserving of canned fruit quality in metal containers is largely defined corrosion resistance of the containers. This is due to the fact that the metal transition to canned fruit in due courses of corrosion processes is lowering the nutritional value and deterioration taste of the product, and while allocation of hydrogen is accompanied by swelling and destruction of metal containers.We have investigated a number of anti-corrosion coatings based on Fe-Cr and Fe-Sn-Ti of their behavior in aggressive mediums canned fruit. For the purpose of modeling such mediums the solutions of most widespread organic acids were used. The research allowed conclude, that in surface solid solutions Fe-Sn-Ti increase the corrosion resistance of carbon steel in aqueous solutions of malic, citric and tartaric acids. This implies that the surface solid solutions’ formation can significantly improve corrosion resistance in aggressive canning mediums.

  3. Regulatory cross-talk in the double par locus of plasmid pB171

    DEFF Research Database (Denmark)

    Ringgaard, Simon; Ebersbach, Gitte; Borch, Jonas

    2007-01-01

    The double par locus of Escherichia coli virulence factor pB171 consists of two adjacent and oppositely oriented par loci of different types, called par1 and par2. par1 encodes an actin ATPase (ParM), and par2 encodes an oscillating, MinD-like ATPase (ParA). The par loci share a central cis-actin...... well with the observed transcriptional regulation of the par operons in vivo and in vitro. Integration host factor (IHF) was identified as a novel factor involved in par2-mediated plasmid partitioning....

  4. Diagnosis of Parietaria judaica pollen allergy using natural and recombinant Par j 1 and Par j 2 allergens.

    Science.gov (United States)

    González-Rioja, R; Ferrer, A; Arilla, M C; Ibarrola, I; Viguera, A R; Andreu, C; Martínez, A; Asturias, J A

    2007-02-01

    Parietaria judaica pollen is one of the main causes of allergic diseases in the Mediterranean area and contains two major allergens, called Par j 1 and Par j 2. To evaluate the diagnostic potential of natural and recombinant forms of Par j 1 and Par j 2 in comparison with standardized P. judaica pollen extract. Thirty patients allergic to P. judaica pollen and 15 control patients were investigated. Skin prick tests and determination of specific IgE levels were performed with commercial P. judaica extract, natural Par j 1 and Par j 2, and recombinant forms of both allergens expressed in P. pastoris. The whole group of patients with allergy to P. judaica had a positive skin test reaction to purified nPar j 1-Par j 2 and rPar j 2 at 5 microg/mL, and no false-positive reactions were detected. Natural and recombinant Par j 1 and Par j 2 showed no significantly different responses in skin tests compared with P. judaica extract. A high correlation was found between the serum-specific IgE levels to P. judaica extract vs. natural (R=0.996; P<0.001) and recombinant allergens (R=0.887 and 0.982 for rPar j 1 and rPar j 2, respectively; P<0.001). rPar j 2 displayed a 100% sensitivity and specificity among P. judaica-allergic patients. In vivo and in vitro diagnosis of P. judaica pollen allergy could be simplified using rPar j 2. This protein showed comparable IgE response and skin prick reactivity with those produced by P. judaica pollen extract.

  5. CORROSION ISSUES ASSOCIATED WITH AUSTENITIC STAINLESS STEEL COMPONENTS USED IN NUCLEAR MATERIALS EXTRACTION AND SEPARATION PROCESSES

    Energy Technology Data Exchange (ETDEWEB)

    Mickalonis, J.; Louthan, M.; Sindelar, R.

    2012-12-17

    This paper illustrated the magnitude of the systems, structures and components used at the Savannah River Site for nuclear materials extraction and separation processes. Corrosion issues, including stress corrosion cracking, pitting, crevice corrosion and other corrosion induced degradation processes are discussed and corrosion mitigation strategies such as a chloride exclusion program and corrosion release testing are also discussed.

  6. Corrosion behaviors and effects of corrosion products of plasma electrolytic oxidation coated AZ31 magnesium alloy under the salt spray corrosion test

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yan; Huang, Zhiquan; Yan, Qin; Liu, Chen; Liu, Peng; Zhang, Yi [State Key Laboratory of Metastable Materials Science and Technology, College of Materials Science and Engineering, Yanshan University, Qinhuangdao 066004 (China); Guo, Changhong; Jiang, Guirong [College of Mechanical Engineering, Yanshan University, Qinhuangdao 066004 (China); Shen, Dejiu, E-mail: DejiuShen@163.com [State Key Laboratory of Metastable Materials Science and Technology, College of Materials Science and Engineering, Yanshan University, Qinhuangdao 066004 (China)

    2016-08-15

    Highlights: • Corrosion behaviors of a PEO coating was investigated after the salt spray test. • Corrosion products have significant effects on corrosion behaviors of the coating. • An electrochemical corrosion model is proposed. - Abstract: The effects of corrosion products on corrosion behaviors of AZ31 magnesium alloy with a plasma electrolytic oxidation (PEO) coating were investigated under the salt spray corrosion test (SSCT). The surface morphology, cross-sectional microstructure, chemical and phase compositions of the PEO coating were determined using scanning electron microscopy (SEM) equipped with energy dispersive X-ray spectroscopy (EDS) and X-ray diffraction analysis (XRD), respectively. Further, the corrosion process of the samples under the SSCT was examined in a non-aqueous electrolyte (methanol) using electrochemical impedance spectroscopy (EIS) coupled with equivalent circuit. The results show that the inner layer of the coating was destroyed firstly and the corrosion products have significant effects on the corrosion behaviors of the coating. The results above are discussed and an electrochemical corrosion model is proposed in the paper.

  7. Surface films and corrosion of copper

    Energy Technology Data Exchange (ETDEWEB)

    Hilden, J.; Laitinen, T.; Maekelae, K.; Saario, T.; Bojinov, M. [VTT Manufacturing Technology, Espoo (Finland)

    1999-03-01

    In Sweden and Finland the spent nuclear fuel is planned to be encapsulated in cast iron canisters that have an outer shield made of copper. The copper shield is responsible for the corrosion protection of the canister construction. General corrosion of the copper is not expected to be the limiting factor in the waste repository environment when estimating the life-time of the canister construction. However, different forms of localised corrosion, i.e. pitting, stress corrosion cracking, or environmentally assisted creep fracture may cause premature failure of the copper shield. Of the probable constituents in the groundwater, nitrites, chlorides, sulphides and carbonates have been suggested to promote localised corrosion of copper. The main assumption made in planning this research program is that the surface films forming on copper in the repository environment largely determine the susceptibility of copper to the different forms of localised corrosion. The availability of reactants, which also may become corrosion rate limiting, is investigated in several other research programs. This research program consists of a set of successive projects targeted at characterising the properties of surface films on copper in repository environment containing different detrimental anions. A further aim was to assess the significance of the anion-induced changes in the stability of the oxide films with regard to localised corrosion of copper. This report summarises the results from a series of investigations on properties of surface films forming on copper in water of pH = 8.9 at temperature of 80 deg C and pressure of 2 MPa. The main results gained so far in this research program are as follows: The surface films forming on copper in the thermodynamic stability region of monovalent copper at 80 deg C consist of a bulk part (about 1 mm thick) which is a good ionic and electronic conductor, and an outer, interfacial layer (0.001 - 0.005 mm thick) which shows p-type semiconductor

  8. Corrosion Evaluation of RERTR Uranium Molybdenum Fuel

    Energy Technology Data Exchange (ETDEWEB)

    A K Wertsching

    2012-09-01

    As part of the National Nuclear Security Agency (NNSA) mandate to replace the use of highly enriched uranium (HEU) fuel for low enriched uranium (LEU) fuel, research into the development of LEU fuel for research reactors has been active since the late 1970’s. Originally referred to as the Reduced Enrichment for Research and Test Reactor (RERTR) program the new effort named Global Threat Reduction Initiative (GTRI) is nearing the goal of replacing the standard aluminum clad dispersion highly enriched uranium aluminide fuel with a new LEU fuel. The five domestic high performance research reactors undergoing this conversion are High Flux Isotope reactor (HFIR), Advanced Test Reactor (ATR), National Institute of Standards and Technology (NIST) Reactor, Missouri University Research Reactor (MURR) and the Massachusetts Institute of Technology Reactor II (MITR-II). The design of these reactors requires a higher neutron flux than other international research reactors, which to this point has posed unique challenges in the design and development of the new mandated LEU fuel. The new design utilizes a monolithic fuel configuration in order to obtain sufficient 235U within the LEU stoichoimetry to maintain the fission reaction within the domestic test reactors. The change from uranium aluminide dispersion fuel type to uranium molybdenum (UMo) monolithic configuration requires examination of possible corrosion issues associated with the new fuel meat. A focused analysis of the UMo fuel under potential corrosion conditions, within the ATR and under aqueous storage indicates a slow and predictable corrosion rate. Additional corrosion testing is recommended for the highest burn-up fuels to confirm observed corrosion rate trends. This corrosion analysis will focus only on the UMo fuel and will address corrosion of ancillary components such as cladding only in terms of how it affects the fuel. The calculations and corrosion scenarios are weighted with a conservative bias to

  9. Corrosion of Magnesium in Multimaterial System

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, Vineet V.; Agnew, Sean

    2017-08-16

    The TMS Magnesium Committee has been actively involved in presenting cutting-edge research and development and the latest trends related to magnesium and its alloys to industry and academia. Topics including magnesium alloy development, applications, mechanism of deformation and corrosion, thermomechanical processing, modelling, etc. have been captured year after year through the Magnesium Technology symposium and conference proceedings at TMS and through special topics in JOM. Every year, based on the unanimous endorsement from the industry and academia, a topic is selected to address the latest developments within this subject in JOM. In continuation with last year’s coverage of Advances and Achievements in In-Situ Analysis of Corrosions and Structure–Property Relationship in Mg Alloys,[1] this year’s topic focuses on the Corrosion of Magnesium in Multimaterial Systems. Magnesium, the lightest of all the structural materials, has garnered much interest in the transportation, electronics packaging, defense equipments and industries alike and are more commonly being incorporated in multimaterial design concepts.[2-4] However, the application of the same is limited due to its highly corrosive nature, and understanding and mitigating the corrosion of magnesium has been a major research challenge.

  10. Analyses of containment structures with corrosion damage

    Energy Technology Data Exchange (ETDEWEB)

    Cherry, J.L. [Sandia National Labs., Albuquerque, NM (United States)

    1997-01-01

    Corrosion damage that has been found in a number of nuclear power plant containment structures can degrade the pressure capacity of the vessel. This has prompted concerns regarding the capacity of corroded containments to withstand accident loadings. To address these concerns, finite element analyses have been performed for a typical PWR Ice Condenser containment structure. Using ABAQUS, the pressure capacity was calculated for a typical vessel with no corrosion damage. Multiple analyses were then performed with the location of the corrosion and the amount of corrosion varied in each analysis. Using a strain-based failure criterion, a {open_quotes}lower bound{close_quotes}, {open_quotes}best estimate{close_quotes}, and {open_quotes}upper bound{close_quotes} failure level was predicted for each case. These limits were established by: determining the amount of variability that exists in material properties of typical containments, estimating the amount of uncertainty associated with the level of modeling detail and modeling assumptions, and estimating the effect of corrosion on the material properties.

  11. Anomalous dissolution of metals and chemical corrosion

    Directory of Open Access Journals (Sweden)

    DRAGUTIN M. DRAZIC

    2005-03-01

    Full Text Available An overview is given of the anomalous behavior of some metals, in particular Fe and Cr, in acidic aqueous solutions during anodic dissolution. The anomaly is recognizable by the fact that during anodic dissolutionmore material dissolves than would be expected from the Faraday law with the use of the expected valence of the formed ions. Mechanical disintegration, gas bubble blocking, hydrogen embrittlement, passive layer cracking and other possible reasons for such behavior have been discussed. It was shown, as suggested by Kolotyrkin and coworkers, that the reason can be, also, the chemical reaction in which H2O molecules with the metal form metal ions and gaseous H2 in a potential independent process. It occurs simultaneously with the electrochemical corrosion process, but the electrochemical process controls the corrosion potential. On the example of Cr in acid solution itwas shown that the reason for the anomalous behavior is dominantly chemical dissolution, which is considerably faster than the electrochemical corrosion, and that the increasing temperature favors chemical reaction, while the other possible reasons for the anomalous behavior are of negligible effect. This effect is much smaller in the case of Fe, but exists. The possible role of the chemical dissolution reacton and hydrogen evolution during pitting of steels and Al and stress corrosion cracking or corrosion fatigue are discussed.

  12. A single parS sequence from the cluster of four sites closest to oriC is necessary and sufficient for proper chromosome segregation in Pseudomonas aeruginosa.

    Directory of Open Access Journals (Sweden)

    Paulina Jecz

    Full Text Available Among the mechanisms that control chromosome segregation in bacteria are highly-conserved partitioning systems comprising three components: ParA protein (a deviant Walker-type ATPase, ParB protein (a DNA-binding element and multiple cis-acting palindromic centromere-like sequences, designated parS. Ten putative parS sites have been identified in the P. aeruginosa PAO1 genome, four localized in close proximity of oriC and six, diverged by more than one nucleotide from a perfect palindromic sequence, dispersed along the chromosome. Here, we constructed and analyzed P. aeruginosa mutants deprived of each single parS sequence and their different combinations. The analysis included evaluation of a set of phenotypic features, chromosome segregation, and ParB localization in the cells. It was found that ParB binds specifically to all ten parS sites, although with different affinities. The P. aeruginosa parS mutant with all ten parS sites modified (parSnull is viable however it demonstrates the phenotype characteristic for parAnull or parBnull mutants: slightly slower growth rate, high frequency of anucleate cells, and defects in motility. The genomic position and sequence of parS determine its role in P. aeruginosa biology. It transpired that any one of the four parS sites proximal to oriC (parS1 to parS4, which are bound by ParB with the highest affinity, is necessary and sufficient for the parABS role in chromosome partitioning. When all these four sites are mutated simultaneously, the strain shows the parSnull phenotype, which indicates that none of the remaining six parS sites can substitute for these four oriC-proximal sites in this function. A single ectopic parS2 (inserted opposite oriC in the parSnull mutant facilitates ParB organization into regularly spaced condensed foci and reverses some of the mutant phenotypes but is not sufficient for accurate chromosome segregation.

  13. A single parS sequence from the cluster of four sites closest to oriC is necessary and sufficient for proper chromosome segregation in Pseudomonas aeruginosa.

    Science.gov (United States)

    Jecz, Paulina; Bartosik, Aneta A; Glabski, Krzysztof; Jagura-Burdzy, Grazyna

    2015-01-01

    Among the mechanisms that control chromosome segregation in bacteria are highly-conserved partitioning systems comprising three components: ParA protein (a deviant Walker-type ATPase), ParB protein (a DNA-binding element) and multiple cis-acting palindromic centromere-like sequences, designated parS. Ten putative parS sites have been identified in the P. aeruginosa PAO1 genome, four localized in close proximity of oriC and six, diverged by more than one nucleotide from a perfect palindromic sequence, dispersed along the chromosome. Here, we constructed and analyzed P. aeruginosa mutants deprived of each single parS sequence and their different combinations. The analysis included evaluation of a set of phenotypic features, chromosome segregation, and ParB localization in the cells. It was found that ParB binds specifically to all ten parS sites, although with different affinities. The P. aeruginosa parS mutant with all ten parS sites modified (parSnull) is viable however it demonstrates the phenotype characteristic for parAnull or parBnull mutants: slightly slower growth rate, high frequency of anucleate cells, and defects in motility. The genomic position and sequence of parS determine its role in P. aeruginosa biology. It transpired that any one of the four parS sites proximal to oriC (parS1 to parS4), which are bound by ParB with the highest affinity, is necessary and sufficient for the parABS role in chromosome partitioning. When all these four sites are mutated simultaneously, the strain shows the parSnull phenotype, which indicates that none of the remaining six parS sites can substitute for these four oriC-proximal sites in this function. A single ectopic parS2 (inserted opposite oriC in the parSnull mutant) facilitates ParB organization into regularly spaced condensed foci and reverses some of the mutant phenotypes but is not sufficient for accurate chromosome segregation.

  14. A physical corrosion model for bioabsorbable metal stents.

    Science.gov (United States)

    Grogan, J A; Leen, S B; McHugh, P E

    2014-05-01

    Absorbable metal stents (AMSs) are an emerging technology in the treatment of heart disease. Computational modelling of AMS performance will facilitate the development of this technology. In this study a physical corrosion model is developed for AMSs based on the finite element method and adaptive meshing. The model addresses a gap between currently available phenomenological corrosion models for AMSs and physical corrosion models that have been developed for more simple geometries than those of a stent. The model developed in this study captures the changing surface of a corroding three-dimensional AMS structure for the case of diffusion-controlled corrosion. Comparisons are made between model predictions and those of previously developed phenomenological corrosion models for AMSs in terms of predicted device geometry and mechanical performance during corrosion. Relationships between alloy solubility and diffusivity in the corrosion environment and device performance during corrosion are also investigated. Copyright © 2014 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  15. Minimizing corrosive action in timber bridges treated with waterborne preservatives

    Science.gov (United States)

    Samuel L. Zelinka; Douglas R. Rammer; James P. Wacker

    2007-01-01

    This work will briefly review published literature and current research activities on the corrosion of metals in contact with wood treated with waterborne alternatives to CCA. In addition, recommendations to minimize these corrosive effects in timber bridges will be discussed.

  16. Application of response surface methodology method in designing corrosion inhibitor

    Science.gov (United States)

    Asmara, Y. P.; Athirah; Siregar, J. P.; Kurniawan, T.; Bachtiar, D.

    2017-10-01

    In oil and gas pipelines and offshore structure, inhibitors have been considered to be the first choice to reduce corrosion rate. There are many corrosion inhibitor compositions available in the market. To produce the best corrosion inhibitor requires many experimental data which is not efficient. These experiments used response surface methodology (RSM) to select corrosion inhibitor compositions. The experiments investigated effects of corrosion inhibition on corrosion rate of low carbon steel in 3% NaCl solution with different concentrations of selected main inhibitor compositions which are ethyl acetate (EA), ethylene glycol (EG) and sodium benzoate (SB). Corrosion rate were calculated using linear polarization resistance (LPR). All of the experiments were set in natural conditions at pH 7. MINITAB® version 15 was used for data analysis. It is shown that a quadratic model is a representative model can predict best corrosion inhibitor composition comprehensibly.

  17. 46 CFR 54.01-35 - Corrosion (modifies UG- 25).

    Science.gov (United States)

    2010-10-01

    ... dangerous fluids, such as acid, poison, corrosives, etc. (d) Exemption from these corrosion allowance... weather or mechanical damage are not acceptable. Note: No applied linings except as provided in Part UCL...

  18. Corrosion performance tests for reinforcing steel in concrete : technical report.

    Science.gov (United States)

    2009-10-01

    The existing test method used to assess the corrosion performance of reinforcing steel embedded in : concrete, mainly ASTM G 109, is labor intensive, time consuming, slow to provide comparative results, : and can be expensive. However, with corrosion...

  19. A corrosion monitoring system for existing reinforced concrete structures.

    Science.gov (United States)

    2015-05-01

    This study evaluated a multi-parameter corrosion monitoring system for existing reinforced concrete structures in chloride-laden service environments. The system was fabricated based on a prototype concrete corrosion measurement system that : had bee...

  20. Detection of microbiologically influenced corrosion by electrochemical noise transients

    NARCIS (Netherlands)

    Homborg, A.M.; Morales, C.F. Leon; Tinga, Tiedo; de Wit, J.H.W.; Mol, J.M.C.

    2014-01-01

    This work investigates the electrochemical processes involved in pitting corrosion induced by microbiologically influenced corrosion by using time-resolved instantaneous frequency information of electrochemical current noise (ECN) transients obtained from Hilbert spectra. In addition to the

  1. corrosion of a carbon steel covered by treated bentonites in ...

    African Journals Online (AJOL)

    F. Arbaoui

    2017-09-01

    clay/aqueous solutions study. Two Algerian bentonites have been considered. The obtained results show that both clays are corrosive even in the absence of chloride ions. We show that this corrosiveness is related to the ...

  2. Corrosion performance tests for reinforcing steel in concrete : test procedures.

    Science.gov (United States)

    2009-09-01

    The existing test method to assess the corrosion performance of reinforcing steel embedded in concrete, mainly : ASTM G109, is labor intensive, time consuming, slow to provide comparative results, and often expensive. : However, corrosion of reinforc...

  3. Corrosion-Resistant High-Entropy Alloys: A Review

    Directory of Open Access Journals (Sweden)

    Yunzhu Shi

    2017-02-01

    Full Text Available Corrosion destroys more than three percent of the world’s gross domestic product. Therefore, the design of highly corrosion-resistant materials is urgently needed. By breaking the classical alloy-design philosophy, high-entropy alloys (HEAs possess unique microstructures, which are solid solutions with random arrangements of multiple elements. The particular locally-disordered chemical environment is expected to lead to unique corrosion-resistant properties. In this review, the studies of the corrosion-resistant HEAs during the last decade are summarized. The corrosion-resistant properties of HEAs in various aqueous environments and the corrosion behavior of HEA coatings are presented. The effects of environments, alloying elements, and processing methods on the corrosion resistance are analyzed in detail. Furthermore, the possible directions of future work regarding the corrosion behavior of HEAs are suggested.

  4. Low Toxicity Corrosion Inhibitors for Smart Coatings Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The Kennedy Space Center (KSC) is located near one of the most corrosive natural environments in the world. Corrosion of KSC ground assets is exacerbated by the...

  5. Evaluation of Encapsulated Inhibitor for Autonomous Corrosion Protection

    Science.gov (United States)

    Johnsey, M. N.; Li, W.; Buhrow, J. W.; Calle, L. M.; Pearman, B. P.; Zhang, X.

    2015-01-01

    This work concerns the development of smart coating technologies based on microencapsulation for the autonomous control of corrosion. Microencapsulation allows the incorporation of corrosion inhibitors into coating which provides protection through corrosion-controlled release of these inhibitors.One critical aspect of a corrosion protective smart coating is the selection of corrosion inhibitor for encapsulation and comparison of the inhibitor function before and after encapsulation. For this purpose, a systematic approach is being used to evaluate free and encapsulated corrosion inhibitors by salt immersion. Visual, optical microscope, and Scanning Electron Microscope (with low-angle backscatter electron detector) are used to evaluate these inhibitors. It has been found that the combination of different characterization tools provide an effective method for evaluation of early stage localized corrosion and the effectiveness of corrosion inhibitors.

  6. Inhibitor for the Corrosion of Mild Steel in H SO

    African Journals Online (AJOL)

    NJD

    electron microscopic studies provided confirmatory evidence of an improved surface condition, due to adsorption, for corrosion protection. KEYWORDS. Terminalia chebula, acid corrosion inhibitor, electrochemical polarization, electrochemical impedance spectroscopy, mild steel. 1. Introduction. Large amounts of sulphuric ...

  7. Corrosion of steel in cracked concrete: a microscale study

    NARCIS (Netherlands)

    Pacheco, J.; Savija, B.; Schlangen, E.; Polder, R.B.

    2014-01-01

    The influence of concrete cracking upon reinforcement corrosion is complex. Cracks allow fast penetration of chlorides, potentially leading to a shorter initiation period of reinforcement corrosion. Structural regulations control acceptable crack width values based on the exposure class of the

  8. Electrolyte Composition for Distinguishing Corrosion Mechanisms in Steel Alloy Screening

    Directory of Open Access Journals (Sweden)

    Ingmar Bösing

    2017-01-01

    Full Text Available The formation and breakdown of passive layers due to pitting corrosion are a major cause of failure of metal structures. The investigation of passivation and pitting corrosion requires two different electrochemical measurements and is therefore a time consuming process. To reduce time in material characterization and to study the interactions of both mechanisms, here, a combined experiment addressing both phenomena is introduced. In the presented electrolyte the different corrosion mechanisms are distinguished and investigated by cyclic voltammograms and polarization scans. The measurements show a passive area, metastable pit growth, and pitting corrosion as well as repassivation. The pitting corrosion is separated from additional dissolution processes and the standard deviation of the corrosion potential is smaller than in other electrolytes. Both passivation and pitting corrosion can be observed in one measurement without additional corrosion attacks. The deviation between different measurements of the same steel is small; this is helpful for the screening of similar materials.

  9. PH and Electrochemical Responsive Materials for Corrosion Smart Coating Applications

    Science.gov (United States)

    Li, Wenyan; Calle, Luz M.

    2008-01-01

    Corrosion is a costly issue for military operations and civil industries. While most corrosion initiates from localized corrosion form, such as pitting, failure directly caused by localized corrosion is the most dangerous kind, because it is difficult to anticipate and prevent, occurs very suddenly and can be catastrophic. One way of preventing these failures is with a coating that can detect and heal localized corrosion. pH and other electrochemical changes are often associated with localized corrosion, so it is expected that materials that are pH or otherwise electrochemical responsive can be used to detect and control corrosion. This paper will review various pH and electrochemical responsive materials and their potential applications in corrosion smart coatings. Current research results in this field will also be reported.

  10. pH Responsive Microcapsules for Corrosion Control

    Science.gov (United States)

    Calle, Luz Marina; Li, Wenyan; Muehlberg, Aaron; Boraas, Samuel; Webster, Dean; JohnstonGelling, Victoria; Croll, Stuart; Taylor, S Ray; Contu, Francesco

    2008-01-01

    The best coatings for corrosion protection provide not only barriers to the environment, but also a controlled release of a corrosion inhibitor, as demanded by the presence of corrosion or mechanical damage. NASA has developed pH sensitive microcapsules (patent pending) that can release their core contents when corrosion starts. The objectives of the research presented here were to encapsulate non-toxic corrosion inhibitors, to incorporate the encapsulated inhibitors into paint formulations, and to test the ability of the paints to control corrosion. Results showed that the encapsulated corrosion inhibitors, specifically Ce(NO3)3 , are effective to control corrosion over long periods of time when incorporated at relatively high pigment volume concentrations into a paint formulation.

  11. Regulatory cross-talk in the double par locus of plasmid pB171

    DEFF Research Database (Denmark)

    Ringgaard, Simon; Ebersbach, Gitte; Borch, Jonas

    2007-01-01

    The double par locus of Escherichia coli virulence factor pB171 consists of two adjacent and oppositely oriented par loci of different types, called par1 and par2. par1 encodes an actin ATPase (ParM), and par2 encodes an oscillating, MinD-like ATPase (ParA). The par loci share a central cis......-acting region of approximately 200 bp, called parC1, located between the two par loci. An additional cis-acting region, parC2, is located downstream of the parAB operon of par2. Here we show that ParR of par1 and ParB of par2 bind cooperatively to unrelated sets of direct repeats in parC1 to form the cognate...... partition and promoter repression complexes. Surprisingly, ParB repressed transcription of the noncognate par operon, indicating cross-talk and possibly epistasis between the two systems. The par promoters, P1 and P2, affected each other negatively. The DNA binding activities of ParR and ParB correlated...

  12. Corrosion of X65 Pipeline Steel Under Deposit and Effect of Corrosion Inhibitor

    Directory of Open Access Journals (Sweden)

    XU Yun-ze

    2016-10-01

    Full Text Available Effect of the deposit on the electrochemical parameters of X65 pipeline steel in oxygen contained sodium chloride solution was studied by EIS and PDS methods. The galvanic corrosion behavior under deposit and effect of different concentration of corrosion inhibitor PBTCA were studied by electrical resistance (ER method combined with ZRA. The results show that the corrosion potential of X65 steel shifts negatively as SiO2 covering its surface and the corrosion rate becomes lower. When the galvanic couple specimen with deposit is electrically connected with the specimen without deposit, anodic polarization occurs on X65 steel under deposit and the galvanic current density decreases from 120μA/cm2 to 50μA/cm2 and keeps stable. As 5×10-5, 8×10-5 and 3×10-4 PBTCA were introduced into the solution, the galvanic current density reaches the highest 1300μA/cm2 and then decreases to 610μA/cm2 keeping stable around 610μA/cm2, corrosion rate of X65 steel under deposit reaches 6.11mm/a. PBTCA accelerates the corrosion of X65 steel under deposit in oxygen contained solution. Through the investigation on the surface of the specimens, serious local corrosion occurs on the X65 steel surface under deposit.

  13. Novel Synthesis of Vegetable Oil Derived Corrosion Inhibitors

    OpenAIRE

    Paul Rostron; Sonia Kasshanna

    2015-01-01

    Two different naturally occurring vegetable oils, Cress seed oil, and Linseed oil were chemically modified via novel one pot synthesis to produce fatty acid derived amides. These were characterized by their ability to prevent corrosion of carbon steel in vigorously stirred, aerated seawater, one of the most corrosive naturally occurring environments. Corrosion inhibitor efficiencies of up to 99.6% or a corrosion rate reduction factor of 250 in this medium is reported. The one pot synthetic st...

  14. On-line Corrosion Monitoring in District Heating Systems

    DEFF Research Database (Denmark)

    Richter, Sonja; Thorarinsdottir, R.I.; Hilbert, Lisbeth Rischel

    2005-01-01

    The corrosion control in district heating systems is today performed primarily with control of the water quality. The corrosion rate is kept low by assuring low dissolved oxygen concentration, high pH and low conductivity. Corrosion failures can occur, e.g. as a result of unknown oxygen ingress......, precipitation of deposits or crevices. The authors describe methods used for on-line monitoring of corrosion, cover the complications and the main results of a Nordic project....

  15. Hot corrosion of the B2 nickel aluminides

    Science.gov (United States)

    Ellis, David L.

    1993-01-01

    The hot corrosion behavior of the B2 nickel aluminides was studied to determine the inherent hot corrosion resistance of the beta nickel aluminides and to develop a mechanism for the hot corrosion of the beta nickel aluminides. The effects of the prior processing of the material, small additions of zirconium, stoichiometry of the materials, and preoxidation of the samples were also examined. Additions of 2, 5, and 15 w/o chromium were used to determine the effect of chromium on the hot corrosion of the beta nickel aluminides and the minimum amount of chromium necessary for good hot corrosion resistance. The results indicate that the beta nickel aluminides have inferior inherent hot corrosion resistance despite their excellent oxidation resistance. Prior processing and zirconium additions had no discernible effect on the hot corrosion resistance of the alloys. Preoxidation extended the incubation period of the alloys only a few hours and was not considered to be an effective means of stopping hot corrosion. Stoichiometry was a major factor in determining the hot corrosion resistance of the alloys with the higher aluminum alloys having a definitely superior hot corrosion resistance. The addition of chromium to the alloys stopped the hot corrosion attack in the alloys tested. From a variety of experimental results, a complex hot corrosion mechanism was proposed. During the early stages of the hot corrosion of these alloys the corrosion is dominated by a local sulphidation/oxidation form of attack. During the intermediate stages of the hot corrosion, the aluminum depletion at the surface leads to a change in the oxidation mechanism from a protective external alumina layer to a mixed nickel-aluminum spinel and nickel oxide that can occur both externally and internally. The material undergoes extensive cracking during the later portions of the hot corrosion.

  16. Microbiologically influenced corrosion of orthodontic metallic appliances.

    Science.gov (United States)

    Kameda, Takashi; Oda, Hirotake; Ohkuma, Kazuo; Sano, Natsuki; Batbayar, Nomintsetseg; Terashima, Yukari; Sato, Soh; Terada, Kazuto

    2014-01-01

    Biocorrosion (microbiologically influenced corrosion; MIC) occur in aquatic habitats varying in nutrient content, temperature, stress and pH. The oral environment of organisms, including humans, should be one of the most hospitable for MIC. Corrosion of metallic appliances in the oral region is one cause of metal allergy in patients. In this study, an inductively coupled plasma-optical emission spectrometer revealed elution of Fe, Cr and Ni from stainless steel (SUS) appliances incubated with oral bacteria. Three-dimensional laser confocal microscopy also revealed that oral bacterial culture promoted increased surface roughness and corrosion pits in SUS appliances. The pH of the supernatant was lowered after co-culture of appliances and oral bacteria in any combinations, but not reached at the level of depassivation pH of their metallic materials. This study showed that Streptococcus mutans and Streptococcus sanguinis which easily created biofilm on the surfaces of teeth and appliances, did corrode orthodontic SUS appliances.

  17. Strain rate effects in stress corrosion cracking

    Energy Technology Data Exchange (ETDEWEB)

    Parkins, R.N. (Newcastle upon Tyne Univ. (UK). Dept. of Metallurgy and Engineering Materials)

    1990-03-01

    Slow strain rate testing (SSRT) was initially developed as a rapid, ad hoc laboratory method for assessing the propensity for metals an environments to promote stress corrosion cracking. It is now clear, however, that there are good theoretical reasons why strain rate, as opposed to stress per se, will often be the controlling parameter in determining whether or not cracks are nucleated and, if so, are propagated. The synergistic effects of the time dependence of corrosion-related reactions and microplastic strain provide the basis for mechanistic understanding of stress corrosion cracking in high-pressure pipelines and other structures. However, while this may be readily comprehended in the context of laboratory slow strain tests, its extension to service situations may be less apparent. Laboratory work involving realistic stressing conditions, including low-frequency cyclic loading, shows that strain or creep rates give good correlation with thresholds for cracking and with crack growth kinetics.

  18. Microbial Corrosion and Cracking in Steel

    DEFF Research Database (Denmark)

    Hilbert, Lisbeth Rischel

    1998-01-01

    and for recommendations in regards to electrochemical monitoring of MIC. The work presented here and further studies are also planned to lead to a Ph.D. thesis on "MIC monitoring based on mechanisms of corrosion".The results of laboratory experiments conducted in the period 1995 to 1997 are summarised. Conclusions...... will be based on results from the entire 3 year period, but only selected experimental data primarily from the latest experiments will be presented in detail here.Microbial corrosion of carbon steel under influence of sulphate-reducing bacteria (SRB) is characterised by the formation of both biofilm...... and corrosion products (ferrous sulphides) on the metal surface. Experiments have been conducted on carbon steel exposed in near neutral (pH 6 to 8.5) saline hydrogen sulphide environment (0 to 100 mg/l total dissolved sulphide) for a period of 14 days. Furthermore coupons have been exposed in a bioreactor...

  19. Microbiological Corrosion in Low Carbon Steels

    Directory of Open Access Journals (Sweden)

    O. Medina–Custodio

    2009-01-01

    Full Text Available The Microbiologically Induced Corrosion affects several industries, such as oil industry where it is estimated that 20% to 30% pipes failures are related with microorganism . The chemical reactions generate ions transfer, this validate the use of electrochemical techniques for its analysis. Coupons submerged in a nutritional medium with presence and absence of three different microorganisms during two periods, 48 hours and 28 days we restudied. Polarization resistance (Rp and Electrochemical Impedance Spectroscopy (EIS techniques we re applied to determine the corrosivity of the systems. The results show a greater corrosive effect of abiotic system, this indicates a microorganisms protection effect to the metal, opposite to the first hypothesis. This result was ratified observing surfaces coupons by using Scanning Electron Microscopy (SEM technique. A possible mechanism based on Evans – Tafel graph is proposed to explain inhibitor microorganism effect.

  20. Method of inhibiting corrosion in acidizing wells

    Energy Technology Data Exchange (ETDEWEB)

    Williams, D.A.; Holifield, P.K.; Looney, J.R.; McDougall, L.A.

    1992-02-18

    This patent describes improvement in a method of acidizing a subterranean formation penetrated by a borehole which has metal pipe positioned therein wherein an aqueous acid solution is pumped down the pipe and into the formation. The improvement comprises introducing components of a nonacetylenic corrosion inhibitor directly into the aqueous acid solution to form the corrosion inhibitor in the acid solution at a concentration to inhibit corrosion of the metal, the components consisting essentially of: an antimony compound which provides from 0.04 to 2.0 wt % of antimony ions in the aqueous acid; from 0.2 to 10 wt % of a quaternary ammonium compound capable of forming a complex with the antimony ions; and from 0.1 to 25 wt % of a surfactant capable of water wetting the pipe.

  1. Seacoast stress corrosion cracking of aluminum alloys

    Science.gov (United States)

    Humphries, T. S.; Nelson, E. E.

    1981-01-01

    The stress corrosion cracking resistance of high strength, wrought aluminum alloys in a seacoast atmosphere was investigated and the results were compared with those obtained in laboratory tests. Round tensile specimens taken from the short transverse grain direction of aluminum plate and stressed up to 100 percent of their yield strengths were exposed to the seacoast and to alternate immersion in salt water and synthetic seawater. Maximum exposure periods of one year at the seacoast, 0.3 or 0.7 of a month for alternate immersion in salt water, and three months for synthetic seawater were indicated for aluminum alloys to avoid false indications of stress corrosion cracking failure resulting from pitting. Correlation of the results was very good among the three test media using the selected exposure periods. It is concluded that either of the laboratory test media is suitable for evaluating the stress corrosion cracking performance of aluminum alloys in seacoast atmosphere.

  2. Mathematical model for galvanic corrosion of steel–copper couple in petroleum waste water in presence of friendly corrosion inhibitor

    National Research Council Canada - National Science Library

    Khadom, Anees A; Abod, Baker M

    2017-01-01

    Galvanic corrosion of steel–copper couple in saline petroleum wastewater in the absence and presence of curcuma extract as corrosion inhibitor was studied as a function of temperature, velocity, and inhibitor concentration...

  3. Research on corrosion mechanism of suspension insulator steel foot of direct current system and measures for corrosion inhibition

    Science.gov (United States)

    Chen, He; Yang, Yueguang; Su, Guolei; Wang, Xiaoqing; Zhang, Hourong; Sun, Xiaoyu; Fan, Youping

    2017-09-01

    There are increasingly serious electrocorrosion phenomena on insulator hardware caused by direct current transmission due to the wide-range popularization of extra high voltage direct current transmission engineering in our country. Steel foot corrosion is the main corrosion for insulators on positive polarity side of transmission lines. On one hand, the corrosion leads to the tapering off of steel foot diameter, having a direct influence on mechanical property of insulators; on the other hand, in condition of corrosion on steel foot wrapped in porcelain ware, the volume of the corrosion product is at least 50% more than that of the original steel foot, leading to bursting of porcelain ware, threatening safe operation of transmission lines. Therefore, it is necessary to conduct research on the phenomenon and propose feasible measures for corrosion inhibition. Starting with the corrosion mechanism, this article proposes two measures for corrosion inhibition, and verifies the inhibition effect in laboratory conditions, providing reference for application in engineering.

  4. A Multifunctional Smart Coating for Autonomous Corrosion Control

    Science.gov (United States)

    Calle, Luz Marina; Buhrow, Jerry W.; Jolley, Scott T.

    2012-01-01

    Corrosion is a destructive process that often causes failure in metallic components and structures. Protective coatings are the most commonly used method of corrosion control. However, progressively stricter environmental regulations have resulted in the ban of many commercially available corrosion protective coatings due to the harmful effects of their solvents or corrosion inhibitors. This work concerns the development of a multifunctional, smart coating for the autonomous control of corrosion. This coating is being developed to have the inherent ability to detect the chemical changes associated with the onset of corrosion and respond autonomously to control it. The multi-functionality of the coating is based on micro-encapsulation technology specifically designed for corrosion control applications. This design has, in addition to all the advantages of other existing microcapsules designs, the corrosion controlled release function that allows the delivery of corrosion indicators and inhibitors on demand only when and where needed. Corrosion indicators as well as corrosion inhibitors have been incorporated into microcapsules, blended into several paint systems, and tested for corrosion detection and protection efficacy. This

  5. Online, real-time corrosion monitoring in district heating systems

    DEFF Research Database (Denmark)

    Hilbert, Lisbeth Rischel; Thorarinsdottir, R.I.

    2005-01-01

    The corrosion control in district heating systems is today performed primarily with control of the water quality. The corrosion rate is kept low by assuring low dissolved oxygen concentration, high pH and low conductivity. Corrosion failures can occur, e.g. as a result of unknown oxygen ingress...

  6. Bacterial Exopolysaccharides For Corrosion Inhibition on Metal Substrates

    Science.gov (United States)

    Biofilms, composed of extra-cellular polymers secreted by bacteria, have been observed to both increase as well as decrease the rate of metal corrosion. Exopolysaccharides derived from Leuconostoc mesenteroides cultures have been shown to inhibit corrosion on corrosion-sensitive metals. The substa...

  7. (TBBI) on copper corrosion in 1 M nitric acid

    African Journals Online (AJOL)

    NIAMIEN PAULIN

    Copper is widely used in various industrial operations; therefore the study of its corrosion inhibition is a subject ... corrosion or dissolution; it is one of the most used metals in the industry because of its mechanical, ...... N-Heterocyclic compounds as corrosion inhibitors for aluminium-copper alloy in Hydrochloric acid. Corros.

  8. Study on corrosion simulation device for marine structural steel

    Indian Academy of Sciences (India)

    A corrosion simulation device was studied using offshore long scale hanging specimens. An Ni–Cu–P steel specimen was studied by analysing its corrosion products and corrosion types. The appearance of the samples and the surface of the metallic substrate after the removal of the rust layer produced by these two ...

  9. 46 CFR 54.25-5 - Corrosion allowance.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Corrosion allowance. 54.25-5 Section 54.25-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PRESSURE VESSELS Construction With Carbon, Alloy, and Heat Treated Steels § 54.25-5 Corrosion allowance. The corrosion allowance...

  10. Electrochemical Characterisation of Filiform Corrosion on Aluminium Rolled Products

    NARCIS (Netherlands)

    Huisert, M.

    2001-01-01

    When aluminium is protected by an organic coating a special form of corrosion can occur underneath the organic coating; filiform corrosion. This form of corrosion manifests itself as threadlike filaments under the coating, it causes local delamination of the coating and the coating cannot protect

  11. 49 CFR 193.2635 - Monitoring corrosion control.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Monitoring corrosion control. 193.2635 Section 193... GAS FACILITIES: FEDERAL SAFETY STANDARDS Maintenance § 193.2635 Monitoring corrosion control. Corrosion protection provided as required by this subpart must be periodically monitored to give early...

  12. Analysis of corrosive environmental factors of seabed sediment

    Indian Academy of Sciences (India)

    Unknown

    The corrosion due to seabed sediment is an important branch of corrosion research. The problem of metal corrosion in seabed sediments has become more and more important with developments in marine oil exploitation and communication for installations such as marine oil- platforms, man-made islands, seabed oil ...

  13. Evaluation of EMP/EMI requirements versus corrosion prevention methods

    Science.gov (United States)

    Gooch, Jan W.; Hawley, Paul M.; Daher, John K.; Lagesse, Daniel M.

    1992-10-01

    Final report covers the application of conductive sealants on an E-3 aircraft for nine months and evaluating the Electromagnetic Pulse (EMP) / Electromagnetic Interference (EMI) Requirements and corrosion damage. Also, additional testing was performed on three conductive sealants for corrosion protection via the salt fog chambers. Using conductive sealants will meet both EMP/EMI and corrosion requirements.

  14. Effect of sulphide on corrosion of copper in seawater

    OpenAIRE

    Gopalakrishna Pillai, A.G.

    1985-01-01

    The corrosion of ETP copper in natural seawater and putrid seawater has been studied. The corrosion rates and the sulphide content were monitored at regular intervals. In the absence of oxygen in the putrid media, the presence of sulphide favoured a reduction in the corrosion rate.

  15. Corrosion of graphite composites in phosphoric acid fuel cells

    Science.gov (United States)

    Christner, L. G.; Dhar, H. P.; Farooque, M.; Kush, A. K.

    1986-01-01

    Polymers, polymer-graphite composites and different carbon materials are being considered for many of the fuel cell stack components. Exposure to concentrated phosphoric acid in the fuel cell environment and to high anodic potential results in corrosion. Relative corrosion rates of these materials, failure modes, plausible mechanisms of corrosion and methods for improvement of these materials are investigated.

  16. Ion implantation of highly corrosive electrolyte battery components

    Science.gov (United States)

    Muller, Rolf H.; Zhang, Shengtao

    1997-01-01

    A method of producing corrosion resistant electrodes and other surfaces in corrosive batteries using ion implantation is described. Solid electrically conductive material is used as the ion implantation source. Battery electrode grids, especially anode grids, can be produced with greatly increased corrosion resistance for use in lead acid, molten salt, end sodium sulfur.

  17. 49 CFR 192.463 - External corrosion control: Cathodic protection.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false External corrosion control: Cathodic protection... for Corrosion Control § 192.463 External corrosion control: Cathodic protection. (a) Each cathodic protection system required by this subpart must provide a level of cathodic protection that complies with one...

  18. Investigations on Atmospheric Corrosion of Low carbon Steel in ...

    African Journals Online (AJOL)

    Nafiisah

    2008-07-17

    Jul 17, 2008 ... contributor to this cost is atmospheric corrosion. Determining the corrosivity of the atmosphere in any country is essential as it would enormously facilitate the task of selecting materials, protection systems, maintenance intervals, and corrosion allowance for metallic structures exposed outdoors. Mauritius ...

  19. Predicting concrete corrosion of sewers using artificial neural network.

    Science.gov (United States)

    Jiang, Guangming; Keller, Jurg; Bond, Philip L; Yuan, Zhiguo

    2016-04-01

    Corrosion is often a major failure mechanism for concrete sewers and under such circumstances the sewer service life is largely determined by the progression of microbially induced concrete corrosion. The modelling of sewer processes has become possible due to the improved understanding of in-sewer transformation. Recent systematic studies about the correlation between the corrosion processes and sewer environment factors should be utilized to improve the prediction capability of service life by sewer models. This paper presents an artificial neural network (ANN)-based approach for modelling the concrete corrosion processes in sewers. The approach included predicting the time for the corrosion to initiate and then predicting the corrosion rate after the initiation period. The ANN model was trained and validated with long-term (4.5 years) corrosion data obtained in laboratory corrosion chambers, and further verified with field measurements in real sewers across Australia. The trained model estimated the corrosion initiation time and corrosion rates very close to those measured in Australian sewers. The ANN model performed better than a multiple regression model also developed on the same dataset. Additionally, the ANN model can serve as a prediction framework for sewer service life, which can be progressively improved and expanded by including corrosion rates measured in different sewer conditions. Furthermore, the proposed methodology holds promise to facilitate the construction of analytical models associated with corrosion processes of concrete sewers. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Study on corrosion simulation device for marine structural steel

    Indian Academy of Sciences (India)

    Unknown

    †Also at Graduate School of the Chinese Academy of Sciences, Beijing 100039, China. MS received 9 January 2003. Abstract. A corrosion simulation device was studied using offshore long scale hanging specimens. An Ni–. Cu–P steel specimen was studied by analysing its corrosion products and corrosion types.

  1. 40 CFR 261.22 - Characteristic of corrosivity.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Characteristic of corrosivity. 261.22... (CONTINUED) IDENTIFICATION AND LISTING OF HAZARDOUS WASTE Characteristics of Hazardous Waste § 261.22 Characteristic of corrosivity. (a) A solid waste exhibits the characteristic of corrosivity if a representative...

  2. Self-Healing Corrosion Protective Sol-Gel Coatings

    NARCIS (Netherlands)

    Abdolah Zadeh, M.

    2016-01-01

    Inspired by the state of the art and the recent advances in the field of self-healing corrosion protective coatings, the thesis entitled “Self-healing corrosion protective sol-gel coatings” addresses novel routes to self-healing corrosion protective sol-gel coatings via extrinsic and intrinsic

  3. Failure Modes in Concrete Repair Systems due to Ongoing Corrosion

    NARCIS (Netherlands)

    Lukovic, M.; Savija, B.; Ye, G.; Schlangen, H.E.J.G.; van Breugel, K.

    2017-01-01

    Corrosion of steel reinforcement is the main cause of deterioration in reinforced concrete structures. It can result in cracking and spalling of the concrete cover. After the damaged cover is repaired, reinforcement corrosion might continue and even accelerate. While the development of the corrosion

  4. 49 CFR 193.2304 - Corrosion control overview.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Corrosion control overview. 193.2304 Section 193... GAS FACILITIES: FEDERAL SAFETY STANDARDS Construction § 193.2304 Corrosion control overview. (a... materials specifications from a corrosion control viewpoint and determines that the materials involved will...

  5. Measurement of weak magnetic field of corrosion current of isolated corrosion center

    Directory of Open Access Journals (Sweden)

    I. V. Bardin

    2015-01-01

    Full Text Available A very small magnetic field of corrosion current, of the order of 10−4 Oe, generated by isolated zinc inclusion in a copper platelet placed in electrolyte has been measured for the first time with a highly sensitive giant magneto-impedance magnetometer. The total corrosion current of the inclusion is estimated comparing the measured magnetic field distribution with corresponding theoretical calculation. The estimated value of the total corrosion current turns out to be in reasonable agreement with that one obtained in the standard gravimetric measurement.

  6. Bacillus sp. Acting as Dual Role for Corrosion Induction and Corrosion Inhibition with Carbon Steel (CS

    Directory of Open Access Journals (Sweden)

    Santosh K. Karn

    2017-10-01

    Full Text Available Present work investigated the role of five different bacteria species as a corrosion inducer as well as corrosion inhibitor with carbon steel (CS. We observed the ability of different bacteria species on the metal surface attachment, biofilm formation, and determined Peroxidase, Catalase enzyme activity in the detached biofilm from the CS surface. We found that each strain has diverse conduct for surface attachment like DS1 3.3, DS2 2.5, DS3 4.3, DS4 4.0, and DS5 4.71 log cfu/cm2 and for biofilm 8.3 log cfu/cm2. The enzyme Peroxidase, Catalase was found in huge concentration inside the biofilm Peroxidase was maximum for DS4 36.0 U/ml and least for DS3 19.54 U/ml. Whereas, Catalase was highest for DS4, DS5 70.14 U/ml and least 57.2 U/ml for DS2. Scanning electron microscopy (SEM was conducted to examine the biofilm and electrochemical impedance spectroscopy (EIS were utilized to observe corrosion in the presence of bacteria. The electrochemical results confirmed that DS1, DS3, DS4, and DS5 strains have statistically significant MIC-factors (Microbially Influenced Corrosion of 5.46, 8.51, 2.36, and 1.04, while DS2 protective effect factor of 0.89. Weight reduction results with carbon steel likewise supports that corrosion was initiated by DS1 and DS3, while DS2 and DS5 have no any impact though with DS4 we watched less weight reduction however assumed no role in the corrosion. We established the relation of Peroxidase enzyme activity of the isolates. DS1, DS3 and having Peroxidase in the range 22.18, 19.54 U/ml which induce the corrosion whereas DS2 and DS5 having 28.57 and 27.0 U/ml has no any effect and DS4 36 U/ml has inhibitory effect, increasing concentration inhibiting the corrosion. For Catalase DS1, DS3 have 67.28, 61.57 U/ml which induce corrosion while DS2 and DS5 57.71 and 59.14 U/ml also has no effect whereas DS4 70.14 U/ml can inhibit corrosion. Results clearly express that in a specific range both enzymes can induce the corrosion

  7. Copper corrosion experiments under anoxic conditions

    Energy Technology Data Exchange (ETDEWEB)

    Ollila, Kaija [VTT Technical Research Centre of Finland, Espoo (Finland)

    2013-06-15

    This report gives results from the corrosion experiments with copper under anoxic conditions. The objective was to study whether hydrogen-evolving corrosion reaction could occur. Copper foil samples were exposed in deaerated deionized water in Erlenmeyer flasks in the glove box with inert atmosphere. Four corrosion experiments (Cu1, Cu2, Cu3 and Cu4) were started, as well as a reference test standing in air. Cu1 and Cu2 had gas tight seals, whereas Cu3 and Cu4 had palladium foils as hydrogen permeable enclosure. The test vessels were stored during the experiments in a closed stainless steel vessel to protect them from the trace oxygen of the gas atmosphere and light. After the reaction time of three and a half years, there were no visible changes in the copper surfaces in any of the tests in the glove box, in contrast the Cu surfaces looked shiny and unaltered. The Cu3 test was terminated after the reaction time of 746 days. The analysis of the Pd-membrane showed the presence of H2 in the test system. If the measured amount of 7.2{center_dot}10{sup 5} mol H{sub 2} was the result of formation of Cu{sub 2}O this would correspond to a 200 nm thick corrosion layer. This was not in agreement with the measured layer thickness with SIMS, which was 6{+-}1 nm. A clear weight loss observed for the Cu3 test vessel throughout the test period suggests the evaporation of water through the epoxy sealing to the closed steel vessel. If this occurred, the anaerobic corrosion of steel surface in humid oxygen-free atmosphere could be a source of hydrogen. A similar weight loss was not observed for the parallel test (Cu4). The reference test standing in air showed visible development of corrosion products.

  8. TRU drum corrosion task team report

    Energy Technology Data Exchange (ETDEWEB)

    Kooda, K.E.; Lavery, C.A.; Zeek, D.P.

    1996-05-01

    During routine inspections in March 1996, transuranic (TRU) waste drums stored at the Radioactive Waste Management Complex (RWMC) were found with pinholes and leaking fluid. These drums were overpacked, and further inspection discovered over 200 drums with similar corrosion. A task team was assigned to investigate the problem with four specific objectives: to identify any other drums in RWMC TRU storage with pinhole corrosion; to evaluate the adequacy of the RWMC inspection process; to determine the precise mechanism(s) generating the pinhole drum corrosion; and to assess the implications of this event for WIPP certifiability of waste drums. The task team investigations analyzed the source of the pinholes to be Hcl-induced localized pitting corrosion. Hcl formation is directly related to the polychlorinated hydrocarbon volatile organic compounds (VOCs) in the waste. Most of the drums showing pinhole corrosion are from Content Code-003 (CC-003) because they contain the highest amounts of polychlorinated VOCs as determined by headspace gas analysis. CC-001 drums represent the only other content code with a significant number of pinhole corrosion drums because their headspace gas VOC content, although significantly less than CC-003, is far greater than that of the other content codes. The exact mechanisms of Hcl formation could not be determined, but radiolytic and reductive dechlorination and direct reduction of halocarbons were analyzed as the likely operable reactions. The team considered the entire range of feasible options, ranked and prioritized the alternatives, and recommended the optimal solution that maximizes protection of worker and public safety while minimizing impacts on RWMC and TRU program operations.

  9. Stress Corrosion-Cracking and Corrosion Fatigue Impact of IZ-C17+ Zinc Nickel on 4340 Steel

    Science.gov (United States)

    2017-05-17

    REPORT NO: NAWCADPAX/TIM-2016/189 STRESS CORROSION-CRACKING AND CORROSION FATIGUE IMPACT OF IZ-C17+ ZINC-NICKEL ON 4340 STEEL by...DEPARTMENT OF THE NAVY NAVAL AIR WARFARE CENTER AIRCRAFT DIVISION PATUXENT RIVER, MARYLAND NAWCADPAX/TIM-2016/189 STRESS ...5a. CONTRACT NUMBER STRESS CORROSION-CRACKING AND CORROSION FATIGUE IMPACT OF IZ-C17+ ZINC-NICKEL ON 4340 STEEL 5b. GRANT NUMBER 5c. PROGRAM

  10. Corrosion of metals in molten salts

    Energy Technology Data Exchange (ETDEWEB)

    Vossen, J.P.T.

    1991-05-15

    Part 1 of this report describes the results of a literature study on the corrosion behavior of metals in molten carbonates. The results form the basis for a doctorate study related to improving the durability of metal separator plates for molten carbonate fuel cells. To gain a better understanding also the literature on corrosion in molten sulfates has been reviewed, the results of which are summarized in Part 2 of this report. For each part a separate abstract has been prepared. 83 figs., 23 tabs., 1 app., 78 refs.

  11. Corrosion resistant alloys for flue gas desulphurisation

    Energy Technology Data Exchange (ETDEWEB)

    Asphahani; Nickerson, J.L. (Haynes International (United States)); Storey, I.J. (Haynes International (United Kingdom))

    Since the mid-seventies, more than 140 field tests have been conducted on several corrosion-resistant alloys in a multitude of flue gas desulphurisation units. In addition, during the eighties, over 30 utilities have installed Hastelloy alloys in the most corrosive conditions in wet scrubbing systems. This article discusses the results from field tests and the experience gained from several installations. The cost effectiveness of thinsheet metallic lining is addressed and the issues of quality control/reliability are reviewed. (6 figures, 5 tables, 7 references). (Author)

  12. A review of topical corrosive black salve.

    Science.gov (United States)

    Eastman, Kristin L; McFarland, Lynne V; Raugi, Gregory J

    2014-04-01

    Black salve is a compound derived from various inert ingredients, but it can be transformed into a corrosive ointment by the addition of bloodroot (Sanguinaria canadensis) or zinc chloride. Black salve products have been advertised as a natural remedy for many ailments, ranging from bee stings to skin cancer. This article reviews the current literature surrounding this compound, which in its corrosive form can be dangerous for use without medical supervision. Patients should be educated about the lack of objective evidence supporting the clinical efficacy of black salve as a skin cancer treatment, as well as the possible cosmetic defects resulting from tissue necrosis secondary to the effects of bloodroot and zinc chloride.

  13. Ionisation D'atomes Par un Laser Carbon Dioxide Intense Par L'effet Tunnel

    Science.gov (United States)

    Xiong, Wei

    Cette these decrit des experiences d'ionisation d'atomes (Xe et K) par un laser CO_2 intense. Des spectrometres de masse et d'energie electronique ont ete developpes pour mesurer le nombre d'ions crees et l'energie des electrons acceleres par le gradient spatial du champ laser. Des details sur ces mesures sont fournis et justifies. On a mesure des energies d'electrons jusqu'a 1000eV, a une intensite de 10^{14} W/cm^2. Les mesures experimentales sont comparees avec deux types de theorie, qui decrivent le processus d'ionisation dans deux limites: l'interaction entre electron et noyau est beaucoup plus forte que celle entre electron et champ laser (processus multiphotonique), ou l'inverse (effect tunnel). Les resultats montrent que la courbe du nombre d'ions crees en fonction de l'intensite n'est pas tres sensible aux details du processus d'ionsisation. Par contre les spectres d'energie des electrons dependent fortement du processus d'ionisation, et on peut en deduire le taux d'ionisation. On trouve que la theorie multiphotonique ne fournit pas une explication satisfaisante aux resultats experimentaux, mais que la theorie de l'effet tunnel s'ajuste bien si on suppose que le seuil d'ionisation peut etre deplace legerement par le champ laser. Le deplacement necessaire du seuil est estime dans cette these, mais une explication theorique reste a trouver.

  14. Health evaluation of drinking water regarding to scaling and corrosion potential using corrosion indexes in Noorabad city, Iran

    Directory of Open Access Journals (Sweden)

    ghodratolah Shams Khorramabadi

    2016-05-01

    Conclusion: Result obtained from studied indexes showed that the drinking water in Noorabad is corrosive and so the water quality in water supply system should be monitored continuously. The best applicable practices for decreasing water corrosion in water supply system are including continuous control of pH, chlorination mechanism and the use of corrosion resistant pipelines and facilities.

  15. A non-destructive test method to monitor corrosion products and corrosion-induced cracking in reinforced cement based materials

    DEFF Research Database (Denmark)

    Michel, Alexander; Pease, Bradley Justin; Peterova, Adela

    2011-01-01

    This paper introduces a non-destructive test method to monitor the development of corrosion products as well as the corrosion-induced formation and propagation of cracks in cementitious materials. A parametric experimental investigation (utilizing x-ray attenuation measurement technique) was cond......This paper introduces a non-destructive test method to monitor the development of corrosion products as well as the corrosion-induced formation and propagation of cracks in cementitious materials. A parametric experimental investigation (utilizing x-ray attenuation measurement technique......) was conducted to describe the impact of water-to-cement ratio and corrosion current density (i.e., corrosion rate) on the reinforcement corrosion process. Focus was placed, in particular on the determination of the corrosion accommodating region (CAR) and time to corrosion-induced cracking. Experimental results......’s law. Furthermore, experimental results demonstrated that the depth of penetration of corrosion products as well as time to corrosion-induced cracking is varying for the different water-to-cement ratios and applied corrosion current densities....

  16. Modélisation de la multi-fissuration d’un alliage d’aluminium 7010 traité par oxydation anodique chromique

    OpenAIRE

    Chaussumier, Michel; Shahzad, Majid; Mabru, Catherine; Chieragatti, Rémy; Rezaï-Aria, Farhad

    2010-01-01

    L’oxydation anodique chromique (OAC) est un procédé de traitement des alliages d’aluminium pour améliorer leur tenue à la corrosion mais il entraîne une très forte réduction de la durée de vie par rapport à l’état usiné. Cette diminution de la durée de vie est largement imputable à la dégradation de la rugosité de la surface occasionnée par la phase de décapage. La présente étude est consacrée à la modélisation de la fissuration à partir des piqûres de décapage observées à la surface d’éch...

  17. Influence du décapage sur la tenue en fatigue de l'alliage Al7010-T7451 traité par oxydation anodique chromique

    OpenAIRE

    Chaussumier, Michel; Shahzad, Majid; Mabru, Catherine; Chieragatti, Rémy; Rezaï-Aria, Farhad

    2009-01-01

    L’oxydation anodique chromique (OAC) est un procédé de traitement des alliages d’aluminium pour améliorer leur tenue à la corrosion. L’influence de ce traitement sur la durée de vie de l’alliage 7010-T7451 est étudiée à partir d’essais de fatigue en flexion rotative. Une réduction de la durée de vie par rapport à l’état usiné est observée. Il est montré que cette diminution de la durée de vie est imputable en grande partie à la dégradation de la rugosité de la surface occasionnée par la phase...

  18. Cataract surgery after pars plana vitrectomy.

    Science.gov (United States)

    Shousha, Mohamed Abou; Yoo, Sonia H

    2010-01-01

    To review recent studies and advances and their possible implications in the care of patients undergoing cataract surgery after pars plana vitrectomy. Optical biometry has shown to be superior to ultrasound biometry in vitrectomized eyes but still not achieving as good results as it does in nonvitrectomized eyes. Blue light-filter intraocular lenses, with their possible advantage of macular protection, have shown no operative or functional disadvantages in vitrectomized eyes, and thus their routine use can be justified. However, presbyopia-correcting intraocular lenses, at least at their current stage of development, generally, are still not accepted for vitrectomized eyes. Combining cataract surgery with intravitreal injections of bevacizumab or triamcinolone acetonide in patients with macular edema and cataract is advisable to avoid exacerbation of the condition and improve visual outcome. Despite the recent advances, incidences of posterior capsular opacification and retinal detachment are still considerable. Understanding ocular anatomical alterations imposed by the previous pars plana vitrectomy surgery and the underlying vitreoretinal disease will allow the surgeon to address the special challenges. Despite that, recent advances in techniques and instrumentation have improved the surgical safety and outcomes, reported complications rates are still relatively high.

  19. Localized Corrosion of Alloy 22 -Fabrication Effects-

    Energy Technology Data Exchange (ETDEWEB)

    Rebak, R B

    2005-11-05

    This report deals with the impact of fabrication processes on the localized corrosion behavior of Alloy 22 (N06022). The four fabrication processes that were analyzed are: (1) Surface stress mitigation of final closure weld, (2) Manufacturing of the mockup container, (3) Black annealing of the container and (4) Use of different heats of Alloy 22 for container fabrication. Immersion and Electrochemical tests performed in the laboratory are generally aggressive and do not represent actual repository environments in Yucca Mountain. For example, to determine the intergranular attack in the heat affected zone of a weldment, tests are conducted in boiling acidic and oxidizing solutions according to ASTM standards. These solutions are used to compare the behavior of differently treated metallic coupons. Similarly for electrochemical tests many times pure sodium chloride or calcium chloride solutions are used. Pure chloride solutions are not representative of the repository environment. (1) Surface Stress Mitigation: When metallic plates are welded, for example using the Gas Tungsten Arc Welding (GTAW) method, residual tensile stresses may develop in the vicinity of the weld seam. Processes such as Low Plasticity Burnishing (LPB) and Laser Shock Peening (LSP) could be applied locally to eliminate the residual stresses produced by welding. In this study, Alloy 22 plates were welded and then the above-mentioned surface treatments were applied to eliminate the residual tensile stresses. The aim of the current study was to comparatively test the corrosion behavior of as-welded (ASW) plates with the corrosion behavior of plates with stress mitigated surfaces. Immersion and electrochemical tests were performed. Results from both immersion and electrochemical corrosion tests show that the corrosion resistance of the mitigated plates was not affected by the surface treatments applied. (2) Behavior of Specimens from a Mockup container: Alloy 22 has been extensively tested for

  20. A Par-1-Par-3-Centrosome Cell Polarity Pathway and Its Tuning for Isotropic Cell Adhesion.

    Science.gov (United States)

    Jiang, Tao; McKinley, R F Andrew; McGill, Melanie A; Angers, Stephane; Harris, Tony J C

    2015-10-19

    To form regulated barriers between body compartments, epithelial cells polarize into apical and basolateral domains and assemble adherens junctions (AJs). Despite close links with polarity networks that generate single polarized domains, AJs distribute isotropically around the cell circumference for adhesion with all neighboring cells [1-3]. How AJs avoid the influence of polarity networks to maintain their isotropy has been unclear. In established epithelia, trans cadherin interactions could maintain AJ isotropy [4], but AJs are dynamic during epithelial development and remodeling [5, 6], and thus specific mechanisms may control their isotropy. In Drosophila, aPKC prevents hyper-polarization of junctions as epithelia develop from cellularization to gastrulation [7]. Here, we show that aPKC does so by inhibiting a positive feedback loop between Bazooka (Baz)/Par-3, a junctional organizer [5, 8-10], and centrosomes. Without aPKC, Baz and centrosomes lose their isotropic distributions and recruit each other to single plasma membrane (PM) domains. Surprisingly, our loss- and gain-of-function analyses show that the Baz-centrosome positive feedback loop is driven by Par-1, a kinase known to phosphorylate Baz and inhibit its basolateral localization [8, 11, 12]. We find that Par-1 promotes the positive feedback loop through both centrosome microtubule effects and Baz phosphorylation. Normally, aPKC attenuates the circuit by expelling Par-1 from the apical domain at gastrulation. The combination of local activation and global inhibition is a common polarization strategy [13-16]. Par-1 seems to couple both effects for a potent Baz polarization mechanism that is regulated for the isotropy of Baz and AJs around the cell circumference. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. A Corrosion Sensor for Monitoring the Early-Stage Environmental Corrosion of A36 Carbon Steel

    Directory of Open Access Journals (Sweden)

    Dong Chen

    2014-08-01

    Full Text Available An innovative prototype sensor containing A36 carbon steel as a capacitor was explored to monitor early-stage corrosion. The sensor detected the changes of the surface- rather than the bulk- property and morphology of A36 during corrosion. Thus it was more sensitive than the conventional electrical resistance corrosion sensors. After being soaked in an aerated 0.2 M NaCl solution, the sensor’s normalized electrical resistance (R/R0 decreased continuously from 1.0 to 0.74 with the extent of corrosion. Meanwhile, the sensor’s normalized capacitance (C/C0 increased continuously from 1.0 to 1.46. X-ray diffraction result indicates that the iron rust on A36 had crystals of lepidocrocite and magnetite.

  2. In Situ X-ray Microtomography of Stress Corrosion Cracking and Corrosion Fatigue in Aluminum Alloys

    Science.gov (United States)

    Singh, Sudhanshu S.; Stannard, Tyler J.; Xiao, Xianghui; Chawla, Nikhilesh

    2017-08-01

    Structural materials are subjected to combinations of stress and corrosive environments that work synergistically to cause premature failure. Therefore, studies on the combined effect of stress and corrosive environments on material behavior are required. Existing studies have been performed in two dimensions that are inadequate for full comprehension of the three-dimensional (3D) processes related to stress corrosion cracking (SCC) and corrosion-fatigue (CF) behavior. Recently, x-ray synchrotron tomography has evolved as an excellent technique to obtain the microstructure in 3D. Moreover, being nondestructive in nature, x-ray synchrotron tomography is well suited to study the evolution of microstructure with time (4D, or fourth dimension in time). This article presents our recent 4D studies on SCC and CF of Al 7075 alloys using x-ray synchrotron tomography.

  3. Corrosion and Stress Corrosion Behaviors of Low and Medium Carbon Steels in Agro-Fluid Media

    Directory of Open Access Journals (Sweden)

    Ayo Samuel AFOLABI

    2007-01-01

    Full Text Available Investigations were carried out to study critically the corrosion behaviour and Stress Corrosion Cracking (SCC of low and medium carbon steels in cassava and cocoa extracts by weight loss measurement and constant extension to fracture method respectively. The results obtained showed that medium carbon steel is more susceptible to corrosion than low carbon steel in both media. SCC is also more in medium carbon steel than low carbon steel in the two media under study. These deductions are due to higher carbon content in medium carbon steel coupled with various aggressive corrosion constituents contained in these media. Hydrogen embrittlement, as well as carbon cracking, is responsible for SCC of these materials in the agro-fluid media.

  4. Corrosive wear. Evaluation of wear and corrosive resistant materials; Noetningskorrosion. Utvaerdering av noetnings- och korrosionsbestaendiga material

    Energy Technology Data Exchange (ETDEWEB)

    Persson, H.; Hjertsen, D.; Waara, P.; Prakash, B.; Hardell, J.

    2007-12-15

    With a new purchase of a waste conveyer screw at hand, for the 'A-warehouse' at the combined power and heating plant at E.ON Norrkoeping, the request for improved construction materials was raised. The previous screw required maintenance with very short intervals due to the difficult operation conditions. With the new screw the expectation is to manage 6 months of operation without interruption. The environment for the screw has two main components that sets the demand on the materials, on one hand the corrosive products that comes along and which forms at digestion of the waste and on the other hand the abrasive content in the waste. The term of the mechanism is wear-corrosion and can give considerably higher material loss than the two mechanisms wear and corrosion separately. Combination of a strong corrosive environment together with extensive wear is something that we today have limited knowledge about. The overall objective of the project has been to establish better wear and corrosive resistant construction materials for a waste conveyer screw that will lead to reduced operational disturbance costs. The evaluation has been performed in both controlled laboratory environments and in field tests, which has given us a better understanding of what materials are more suitable in this tough environment and has given us a tool for future predictions of the wear rate of the different material. The new conveyer screw, installed in February 2007 and with which the field test have been performed, has considerably reduced the wear of the construction and the target of 6 month maintenance-free operation is met with this screw for all the evaluated materials. The wear along the screw varies very much and with a clear trend for all the materials to increase towards the feeding direction of the screw. As an example, the wear plate SS2377 (stainless duplex steel) has a useful life at the most affected areas that is calculated to be 1077 days of operation with the

  5. Contribution to Yttria corrosion study by liquid uranium; Contribution a l`etude de la corrosion de l`yttria par l`uranium liquide

    Energy Technology Data Exchange (ETDEWEB)

    Tournier, C.

    1995-02-01

    We are studying liquid uranium and polycrystalline Yttria interactions under secondary vacuum. The type, morphology and thickness of interfacial reaction products between U and Y{sub 2}O{sub 3} are examined by optical and confocal microscopy, SEM, X ray diffraction, X analysis and XPS. The most important parameters are the stoechiometry and microstructure of the Yttria, the oxygen partial pressure of the furnace atmosphere, pO{sub 2}, and the duration and temperature of experiments. In the thermodynamic modelization, we take into account exchanges at the ceramic/metal interface and exchanges between the molten metal and the furnace atmosphere. Liquid uranium reacts with Yttria to form UO{sub 2} at the interface which gradually changes into a solid solution UO{sub 2}-Y{sub 2}O{sub 3}. The total thickness of reaction products results from two opposing reactions: (i) oxidation of uranium by Yttria (low pO{sub 2}) or by the atmosphere (high pO{sub 2}), controlled by migration of oxygen vacancies at Yttria grain boundaries. (ii) deoxidation caused by the formation of volatile uranium monoxide. On the other hand, we observed a transition of the type ``non-wettability {yields} wettability `` which occurs subsequent to an increase of the stoichiometric variation x in Y{sub 2}O{sub 3-x}. (author). 69 refs., 76 figs., 30 tabs.

  6. Monitoring corrosion of steel bars in reinforced concrete structures.

    Science.gov (United States)

    Verma, Sanjeev Kumar; Bhadauria, Sudhir Singh; Akhtar, Saleem

    2014-01-01

    Corrosion of steel bars embedded in reinforced concrete (RC) structures reduces the service life and durability of structures causing early failure of structure, which costs significantly for inspection and maintenance of deteriorating structures. Hence, monitoring of reinforcement corrosion is of significant importance for preventing premature failure of structures. This paper attempts to present the importance of monitoring reinforcement corrosion and describes the different methods for evaluating the corrosion state of RC structures, especially hal-cell potential (HCP) method. This paper also presents few techniques to protect concrete from corrosion.

  7. Neural network for prediction of superheater fireside corrosion

    Energy Technology Data Exchange (ETDEWEB)

    Makkonen, P. [Foster Wheeler Energia Oy, Karhula R and D Center, Karhula (Finland)

    1998-12-31

    Superheater corrosion causes vast annual losses to the power companies. If the corrosion could be reliably predicted, new power plants could be designed accordingly, and knowledge of fuel selection and determination of process conditions could be utilized to minimize superheater corrosion. If relations between inputs and the output are poorly known, conventional models depending on corrosion theories will fail. A prediction model based on a neural network is capable of learning from errors and improving its performance as the amount of data increases. The neural network developed during this study predicts superheater corrosion with 80 % accuracy at early stage of the project. (orig.) 10 refs.

  8. Deadleg corrosion in oil and gas producing facilities

    Energy Technology Data Exchange (ETDEWEB)

    Al-Ghamdi, A.M.; Chen, E.Y.

    1988-01-01

    Deadlegs in oil and gas producing facilities create the highest potential for corrosion damage. Unexpected leaks in deadlegs could develop in a normally non-corrosive environment. These leaks are promoted by different corrosion mechanisms, such as concentration cells, bacterial growth, under-the-deposit corrosion etc. In this paper, several case histories of deadleg leaks and remedial actions are discussed. Deadleg corrosion can be effectively controlled by proper system design, material selection, and operation. These measures can only be accomplished by training the personnel involved to be aware of the potential problem.

  9. Corrosion of Steel in Concrete – Thermodynamical Aspects

    DEFF Research Database (Denmark)

    Küter, Andre; Møller, Per; Geiker, Mette Rica

    2004-01-01

    formation and composition of corrosion products have been proposed. Suggested reactions, except half-cell reactions, are verified or rejected based on their Gibbs free energy, while the electrode potential is calculated for half-cell reactions. Corrosion products postulated to form are related......The present understanding of selected corrosion phenomena in reinforced concrete is reviewed. Special emphasis is given to chloride induced corrosion. There is a general acceptance of the basic corrosion mechanism for steel in concrete. However different anodic reactions governing the subsequent...

  10. Corrosion of Steel in Concrete, Part I – Mechanisms

    DEFF Research Database (Denmark)

    Küter, André; Møller, Per; Geiker, Mette Rica

    2006-01-01

    prematurely. Reinforcement corrosion is identified to be the foremost cause of deterioration. Steel in concrete is normally protected by a passive layer due the high alkalinity of the concrete pore solution; corrosion is initiated by neutralization through atmospheric carbon dioxide and by ingress...... of depassivation ions, especially chloride ions. The background and consequences of deterioration of reinforced concrete structures caused by steel corrosion are summarized. Selected corrosion mechanisms postulated in the literature are briefly discussed and related to observations. The key factors controlling...... initiation and propagation of corrosion of steel in concrete are outlined....

  11. High Temperature Corrosion in Biomass-Fired Boilers

    DEFF Research Database (Denmark)

    Henriksen, Niels; Montgomery, Melanie; Hede Larsen, Ole

    2002-01-01

    condense on superheater components. This gives rise to specific corrosion problems not previously encountered in coal-fired power plants. The type of corrosion attack can be directly ascribed to the composition of the deposit and the metal surface temperature. To avoid such high corrosion rates, woodchip...... has also been utilised as a fuel. Combustion of woodchip results in a smaller amount of ash, and potassium and chlorine are present in lesser amounts. However, significant corrosion rates were still seen. A case study of a woodchip fired boiler is described. The corrosion mechanisms in both straw...

  12. Plasma polymerized hexamethyldisiloxane thin films for corrosion protection

    Science.gov (United States)

    Saloum, S.; Alkhaled, B.; Alsadat, W.; Kakhia, M.; Shaker, S. A.

    2018-01-01

    This study focused on the corrosion protection performance of plasma polymerized HMDSO thin films in two different corrosive medias, 0.3M NaCl and 0.3M H2SO4. The pp-HMDSO thin films were deposited on steel substrates for electrochemical tests using the potentiodynamic polarization technique, they were deposited also on aluminum and silicon substrates to investigate their resistance to corrosion, through the analysis of the degradation of microhardness and morphology, respectively, after immersion of the substrates for one week in the corrosive media. The results showed promising corrosion protection properties of the pp-HMDSO thin films.

  13. Improved Corrosion Resistance of Pulse Plated Nickel through Crystallisation Control

    DEFF Research Database (Denmark)

    Tang, Peter Torben; Watanabe, Tohru; Andersen, Jens Enevold Thaulov

    1995-01-01

    When electrodeposition of nickel is used for corrosion protection of steel two aspects are important. The porosity of the coating and the resistance against corrosion provided by the coating itself. Using simple pulsed current (PC) plating, the size of the deposited crystals can be significantly...... smaller, thereby reducing porosity correspondingly. This usually also leads to improved hardness of the coating. Introducing pulse reversal (PR) plating, the most active crystals are continuously dissolved during the anodic pulse, providing a coating with improved subsequent corrosion resistance in almost...... any corrosive environment. This correlation between film texture and corrosion resistance will be discussed....

  14. Trends in the automotive paint industry for corrosion protection

    Energy Technology Data Exchange (ETDEWEB)

    Blandin, Nathalie; Brunat, William [PPG Industries France, 3 Z.A.E. Les Dix Muids, B.P. 89, F-59583 Marly (France); Neuhaus, Ralf [PPG Industries Lacke GmbH, Stackenbergstrasse 34, D-42329 Wuppertal (Germany); Sibille, Ettore [PPG Industries Italia, Via Serra11, I-15028 Quattordio (Italy)

    2004-07-01

    Since many years ED-paints are protecting car bodies against corrosion. Currently the automotive paint industry is faced with increasing demands of higher levels of corrosion protection and also requests to comply with new environmental regulations and economical pressures. Some key factors that contributed significantly towards the improvement of corrosion protection systems are: - New generations of lead free ED-paints; - Weldable organic thin film for corrosion protection, especially in box cavities and flange areas. The goal of this paper is to show how the various elements of the 'anti-corrosion package' interact. (authors)

  15. Prevention of Corrosion Rate by Natural Inhibitor Papaya Leaf Extract

    OpenAIRE

    Bow, Yohandri

    2012-01-01

    Corrosion is an event of damage or deterioration of a metal caused by reaction with the environtment. Corrosion process can be prevented by the addition of corrosion inhibitor. Papaya leaf extract is an organic material that could potentially be used as a corrosion inhibitor because it contains N-acetyl- glukosamida and amino acid. The purpose of this study is to determine the effects of brine concentration and surface area on the rate of corrosion of a metal plate that can be used as refere...

  16. Recent Developments on Microencapsulation for Autonomous Corrosion Protection

    Science.gov (United States)

    Calle, Luz M.; Li, Wenyan; Buhrow, Jerry W.; Fitzpatrick, Lilliana; Jolley, Scott T.; Surma, Jan M.; Pearman, Benjamin P.; Zhang, Xuejun

    2014-01-01

    This work concerns recent progress in the development of a multifunctional smart coating based on microencapsulation for the autonomous control of corrosion. Microencapsulation allows the incorporation of desired corrosion control functionalities, such as early corrosion detection and inhibition through corrosion controlled release of corrosion indicators and inhibitors, as well as self-healing agent release when mechanical damage occurs.While proof-of-concept results have been reported previously, more recent efforts have been concentrated in technical developments to improve coating compatibility, synthesis procedure scalability, as well as fine tuning the release property of encapsulated active agents.

  17. Accelerated Test Method for Corrosion Protective Coatings Project

    Science.gov (United States)

    Falker, John; Zeitlin, Nancy; Calle, Luz

    2015-01-01

    This project seeks to develop a new accelerated corrosion test method that predicts the long-term corrosion protection performance of spaceport structure coatings as accurately and reliably as current long-term atmospheric exposure tests. This new accelerated test method will shorten the time needed to evaluate the corrosion protection performance of coatings for NASA's critical ground support structures. Lifetime prediction for spaceport structure coatings has a 5-year qualification cycle using atmospheric exposure. Current accelerated corrosion tests often provide false positives and negatives for coating performance, do not correlate to atmospheric corrosion exposure results, and do not correlate with atmospheric exposure timescales for lifetime prediction.

  18. Apollo experience report: The problem of stress-corrosion cracking

    Science.gov (United States)

    Johnson, R. E.

    1973-01-01

    Stress-corrosion cracking has been the most common cause of structural-material failures in the Apollo Program. The frequency of stress-corrosion cracking has been high and the magnitude of the problem, in terms of hardware lost and time and money expended, has been significant. In this report, the significant Apollo Program experiences with stress-corrosion cracking are discussed. The causes of stress-corrosion cracking and the corrective actions are discussed, in terminology familiar to design engineers and management personnel, to show how stress-corrosion cracking can be prevented.

  19. Research on the corrosion inhibitors of zinc in hydrochloric acid

    Science.gov (United States)

    Sun, C. X.; Chen, Y. M.; Xu, H. W.; Huang, C. S.; Zhang, M.; Wu, J. Y.; Chen, M.; Xue, M.

    2017-06-01

    Three organic compounds were tested as zinc corrosion inhibitors in hydrochloric acid: cetyltrimethyl ammonium bromide (CTAB), nicotini acid, bromohexadecyl pyridine. The static coupon test results indicate that CTAB and bromohexadecyl pyridine offer the best zinc corrosion protection, while nicotinic acid accelerates zinc corrosion. The polarization results indicate that CTAB, nicotinic acid and bromohexadecyl pyridine induce a positive shift in the E0 of zinc in hydrochloric acid. A complex of CTAB and bromohexadecyl pyridine inhibits the corrosion of zinc in hydrochloric acid. SEM results indicate that the CTAB and bromohexadecyl pyridine formed a uniform and compact membrane on the surface of zinc that subsequently protects the zinc from effective corrosion.

  20. Long Term Corrosion/Degradation Test Six Year Results

    Energy Technology Data Exchange (ETDEWEB)

    M. K. Adler Flitton; C. W. Bishop; M. E. Delwiche; T. S. Yoder

    2004-09-01

    The Subsurface Disposal Area (SDA) of the Radioactive Waste Management Complex (RWMC) located at the Idaho National Engineering and Environmental Laboratory (INEEL) contains neutron-activated metals from non-fuel, nuclear reactor core components. The Long-Term Corrosion/Degradation (LTCD) Test is designed to obtain site-specific corrosion rates to support efforts to more accurately estimate the transfer of activated elements to the environment. The test is using two proven, industry-standard methods—direct corrosion testing using metal coupons, and monitored corrosion testing using electrical/resistance probes—to determine corrosion rates for various metal alloys generally representing the metals of interest buried at the SDA, including Type 304L stainless steel, Type 316L stainless steel, Inconel 718, Beryllium S200F, Aluminum 6061, Zircaloy-4, low-carbon steel, and Ferralium 255. In the direct testing, metal coupons are retrieved for corrosion evaluation after having been buried in SDA backfill soil and exposed to natural SDA environmental conditions for times ranging from one year to as many as 32 years, depending on research needs and funding availability. In the monitored testing, electrical/resistance probes buried in SDA backfill soil will provide corrosion data for the duration of the test or until the probes fail. This report provides an update describing the current status of the test and documents results to date. Data from the one-year and three-year results are also included, for comparison and evaluation of trends. In the six-year results, most metals being tested showed extremely low measurable rates of general corrosion. For Type 304L stainless steel, Type 316L stainless steel, Inconel 718, and Ferralium 255, corrosion rates fell in the range of “no reportable” to 0.0002 mils per year (MPY). Corrosion rates for Zircaloy-4 ranged from no measurable corrosion to 0.0001 MPY. These rates are two orders of magnitude lower than those specified in

  1. Corrosion of copper alloys in sulphide containing district heting systems

    DEFF Research Database (Denmark)

    Thorarinsdottir, R.I.; Maahn, Ernst Emanuel

    1999-01-01

    Copper and some copper alloys are prone to corrosion in sulphide containing geothermal water analogous to corrosion observed in district heating systems containing sulphide due to sulphate reducing bacteria. In order to study the corrosion of copper alloys under practical conditions a test...... was carried out at four sites in the Reykjavik District Heating System. The geothermal water chemistry is different at each site. The corrosion rate and the amount and chemical composition of deposits on weight loss coupons of six different copper alloys are described after exposure of 12 and 18 months......, respectively. Some major differences in scaling composition and the degree of corrosion attack are observed between alloys and water types....

  2. The PAR Proteins: Fundamental Players in Animal Cell Polarization

    OpenAIRE

    Goldstein, Bob; Macara, Ian G.

    2007-01-01

    The par genes were discovered in genetic screens for regulators of cytoplasmic partitioning in the early embryo of C. elegans, and encode six different proteins required for asymmetric cell division by the worm zygote. Some of the PAR proteins are localized asymmetrically and form physical complexes with one another. Strikingly, the PAR proteins have been found to regulate cell polarization in many different contexts in diverse animals, suggesting they form part of an ancient and fundamental ...

  3. The Effects of Corrosive Chemicals on Corrosion Rate of Steel Reinforcement Bars: I. Swamp Water

    Directory of Open Access Journals (Sweden)

    Sulistyoweni Widanarko

    2010-10-01

    Full Text Available Most of infrastructures using steel concrete to reinforce the strength of concrete. Steel concrete is so vulnerable to chemical compounds that can cause corrosion. It can happen due to the presence of chemical compounds in acid environment in low pH level. These chemical compounds are SO42-, Cl-, NO3-. There are many swamp area in Indonesia. The acid contents and the concentration of ion sulphate, chlorides, and nitrate are higher in the swamp water than in the ground water .The objective of this research was to find out the influence of corrosive chemicals in the swamp water to the steel concrete corrosion rate. There were two treatment used: (1 emerging ST 37 and ST 60 within 60 days in the 'polluted' swamp water, (2 moving the ST 37 up and down periodically in the ' polluted' swamp water. Three variation of 'polluted' swamp water were made by increasing the concentration of corrosive chemical up to 1X, 5X and 10X respectively. The corrosion rate was measured by using an Immersion Method. The result of Immersion test showed that chloride had the greatest influence to corrosion rate of ST 37 and ST 60 and followed by sulphate and Nitrate. Corrosion rate value for ST 37 is 24.29 mpy and for ST 60 is 22.76 mpy. By moving the sample up and down, the corrosion rate of ST 37 increase up to 37.59 mpy, and chloride still having the greatest influence, followed by sulphate and nitrate.

  4. Le virus Zika : des questions qui méritent réponse | CRDI - Centre ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    30 mars 2016 ... Nous savons que le virus Zika, tout comme les virus similaires Chikungunya et Dengue, sont transmis par la piqure d'un moustique infecté appelé Aedes aegypti. Les autorités sanitaires rapportent que le virus est prévalent dans les régions urbaines densément peuplées, où les moustiques sont en contact ...

  5. Corrosion protective coating for metallic materials

    Science.gov (United States)

    Buchheit, Rudolph G.; Martinez, Michael A.

    1998-01-01

    Corrosion protective coatings for metallic materials, particularly aluminum and aluminum alloys, produced with simple, low-cost equipment and materials other than toxic metals or metal salts, or metal cyanides. The metallic material is cleaned, degreased, and deoxidized, the surface is converted to a substantially alkaline condition, and the surface is chemically sealed with inorganic metal compounds.

  6. Corrosion of metal samples rapidly measured

    Science.gov (United States)

    Maskell, C. E.

    1966-01-01

    Corrosion of a large number of metal samples that have been exposed to controlled environment is accurately and rapidly measured. Wire samples of the metal are embedded in clear plastic and sectioned for microexamination. Unexposed wire can be included in the matrix as a reference.

  7. Corrosion performance of inorganic coatings in seawater

    NARCIS (Netherlands)

    Zhang, X.; Buter, S.J.; Ferrari, G.M.; Westing, E. van; Kowalski, L.

    2011-01-01

    Inorganic coatings are widely used to protect carbon steel hydraulic cylinder rods from wear and corrosion in aggressive offshore environment. Different types of lay-ers such as Ni/Cr, Al2O3, Cr2O3, TiO2, and Inconel 625 layers were applied to the carbon steels by plasma, High Velocity Oxygen Fuel

  8. Poly(aniline) in corrosion resistant coatings

    Energy Technology Data Exchange (ETDEWEB)

    McAndrew, T.P.; Miller, S.A.; Gilicinski, A.G.; Robeson, L.M. [Air Products and Chemicals, Inc., Allentown, PA (United States)

    1996-10-01

    During the past two decades, one of the most active fields of solid-state science has been electrically conductive polymers. These are polymers which are insulators as prepared, but which can be converted to polymers having many or all the properties of a metal, by virtue of appropriate chemical/electrochemical oxidation or reduction. Typically, applications examined for electrically conductive polymers have been in areas such as rechargeable batteries and charge dissipative coatings. Recently it has been reported that poly(aniline), in its electrically conductive, protonated form, shows excellent performance as a coating for preventing the corrosion of carbon steel. The present research has shown that in fact, the non-conductive, unprotonated form of poly(aniline) shows even better performance in corrosion prevention than the conductive form. Moreover, it has been shown that poly(aniline) can be blended with other polymers to improve their corrosion resistance performance (e.g., polyimides), or used as a hardener for epoxides or diisocyanates, to give very good corrosion resistant coatings. Poly(aniline) performance is explained in terms of its ability to form dense, adherent films, and create a basic surface on carbon steel surfaces.

  9. Ballast Water Treatment Corrosion Scoping Study

    Science.gov (United States)

    2011-10-01

    Office of Environmental Standards, 2009) Organism Size > 50μm* > 10μm & ≤ 50μm ≤ 10μm Pathogens and Indicators Toxicogenic V. cholerae O1...type of corrosion is generally associated with the presence of small volumes of stagnant water beneath deposits and seals, in crevices, or where nuts

  10. Corrosion, haemocompatibility and bacterial adhesion behaviour of ...

    Indian Academy of Sciences (India)

    Bacterial adhesion, haemocompatibility and corrosion behaviour of TiZrN coating were examined in order to evaluate the coating's compatibility for ideal implant. Results revealed that TiZrN coatings exhibited less bacterial attachment against Staphylococcus aureus and Escherichia coli bacteria, negligible platelets ...

  11. EXTRACT OF COMBRETUM MICRANTHUM AS CORROSION ...

    African Journals Online (AJOL)

    user

    2016-10-04

    Oct 4, 2016 ... however exposed to the action of acids, bases, salt water in industries and marine environment and these medium are generally accompanied by considerable dissolution of the metal, so arises the problem of the material protection. The use of corrosion inhibitors is a current practice in industry [4, 5].

  12. Corrosion and Cracking of Reinforced Concrete

    DEFF Research Database (Denmark)

    Thoft-Christensen, Palle

    Modelling of the deterioration of reinforced concrete has in recent years changed from being a deterministic modelling based on experience to be stochastic modelling based on sound and consistent physical, chemical and mechanical principles. In this paper is presented a brief review of modern mod...... for time to initial corrosion, time to initial cracking, and time to a given crack width may be obtained....

  13. Corrosion, haemocompatibility and bacterial adhesion behaviour of ...

    Indian Academy of Sciences (India)

    TiZrN coating was deposited on 316L stainless steel (SS) by the reactive magnetron co-sputtering technique. Cubic phase of TiZrN with uniform surface morphology was observed by X-ray diffraction and atomic force microscopy. Bacterial adhesion, haemocompatibility and corrosion behaviour of TiZrN coating were ...

  14. Corrosion of reinforcement induced by environment containing ...

    Indian Academy of Sciences (India)

    Reinforced concrete structures during their exploitation may be exposed to the common action of carbonation and chlorides causing corrosion of steel reinforcement. Therefore, the related data seem to be interesting and important when the evaluation of the service life of the structures is the object of interest. This fact was a ...

  15. Evaluation Of Corrosion And Encrustation Potentials Of ...

    African Journals Online (AJOL)

    This article presents results of groundwater quality assessment based on some corrosion-encrustation index parameters (CEIP) and drinking water standards. The CEIP concentration results indicate that the hydrogen ion concentration, pH ranges from 5.4 to 7.6, total iron, Fe varies from 0.02 to 3.0mg/l; Manganese Mn ...

  16. Assessing corrosion of MSE wall reinforcement.

    Science.gov (United States)

    2010-09-01

    The primary objective of this study was to extract reinforcement coupons from select MSE walls and document the extent of corrosion. In doing this, a baseline has been established against which coupons extracted in the future can be compared. A secon...

  17. Corrosion of reinforcement induced by environment containing ...

    Indian Academy of Sciences (India)

    Unknown

    Abstract. Reinforced concrete structures during their exploitation may be exposed to the common action of carbonation and chlorides causing corrosion of steel reinforcement. Therefore, the related data seem to be interesting and important when the evaluation of the service life of the structures is the object of interest. This.

  18. High Temperature Corrosion in Biomass Incineration Plants

    DEFF Research Database (Denmark)

    Montgomery, Melanie; Maahn, Ernst emanuel; Gotthjælp, K.

    1997-01-01

    The aim of the project is to study the role of ash deposits in high temperature corrosion of superheater materials in biomass and refuse fire combined heat and power plants. The project has included the two main activities: a) A chemical characterisation of ash deposits collected from a major...

  19. Investigation of Electronic Corrosion at Device Level

    DEFF Research Database (Denmark)

    Jellesen, Morten Stendahl; Minzari, Daniel; Rathinavelu, Umadevi

    2010-01-01

    board assembly (PCBA) in the device is more prone to corrosion reliability and this was further analysed using thermography to detect areas that have high risk of condensation due to lower temperature under working condition. Tested PCBAs are subjected to detailed investigation before and after testing...

  20. Detecting Corrosion Under Paint and Insulation

    Science.gov (United States)

    Bastin, Gary L.

    2011-01-01

    Corrosion is a major concern at the Kennedy Space Center in Florida due to the proximity of the center to the Atlantic Ocean and to salt water lagoons. High humidity, salt fogs, and ocean breezes, provide an ideal environment in which painted steel structures become corroded. Maintenance of painted steel structures is a never-ending process.

  1. Corrosion free phosphoric acid fuel cell

    Science.gov (United States)

    Wright, Maynard K.

    1990-01-01

    A phosphoric acid fuel cell with an electrolyte fuel system which supplies electrolyte via a wick disposed adjacent a cathode to an absorbent matrix which transports the electrolyte to portions of the cathode and an anode which overlaps the cathode on all sides to prevent corrosion within the cell.

  2. INVESTIGATIONS ON THE CORROSION OF CONSTRUCTIONAL ...

    African Journals Online (AJOL)

    BCSE

    products of analytical grade and were used without further purifications. Distilled water was used as the solvent. The electrochemical measurements .... After 30 days of exposition in the humid atmospheric corrosion, the different samples were rusted up to 9.1% for S275, 40.6% for S355 and 51.9% for S235. It seems that for ...

  3. Corrosion protective coating for metallic materials

    Science.gov (United States)

    Buchheit, R.G.; Martinez, M.A.

    1998-05-26

    Corrosion protective coatings for metallic materials, particularly aluminum and aluminum alloys, produced with simple, low-cost equipment and materials other than toxic metals or metal salts, or metal cyanides is disclosed. The metallic material is cleaned, degreased, and deoxidized, the surface is converted to a substantially alkaline condition, and the surface is chemically sealed with inorganic metal compounds. 1 fig.

  4. Corrosion of carbon-alloyed iron aluminides

    Indian Academy of Sciences (India)

    Unknown

    Corrosion of carbon-alloyed iron aluminides. M SEN, R BALASUBRAMANIAM* and A V RAMESH KUMAR†. Department of Materials and Metallurgical Engineering, Indian Institute of Technology, Kanpur 208 016, India. †Defence Materials Stores and Research Development Establishment, Kanpur 208 013, India.

  5. Kinetic studies of stress-corrosion cracking

    Science.gov (United States)

    Noronha, P. J.

    1977-01-01

    Use of time-to-failure curves for stress-corrosion cracking processes may lead to incorrect estimates of structural life, if material is strongly dependent upon prestress levels. Technique characterizes kinetics of crackgrowth rates and intermediate arrest times by load-level changes.

  6. Stress Corrosion Cracking of Certain Aluminum Alloys

    Science.gov (United States)

    Hasse, K. R.; Dorward, R. C.

    1983-01-01

    SC resistance of new high-strength alloys tested. Research report describes progress in continuing investigation of stress corrosion (SC) cracking of some aluminum alloys. Objective of program is comparing SC behavior of newer high-strength alloys with established SC-resistant alloy.

  7. Cold end corrosion causes and cures

    Energy Technology Data Exchange (ETDEWEB)

    Ganapathy, V.

    1989-01-01

    Calculating dew points of various acid gases and options for reducing cold end corrosion of heat recovery exchangers are presented. Whenever fossil fuels containing sulfur are fired in heater or boilers, sulfur dioxide, and to a small extent sulfur trioxide, are formed in addition to CO/sub 2/ and water vapor. The SO/sub 3/ combines with water vapor in the flue gas to form sulfuric acid and condenses on heat transfer surfaces, which could lead to corrosion and destruction of the surfaces. This condensation occurs on surfaces that are at or below the dew point of the acid gas. Also, when cooled below the water vapor dew point, CO/sub 2/ can combine with water vapor to form carbonic acid, which though weak, can attack mild steel. While thermal efficiency of the equipment is increased with reduction in exit gas temperature (or enthalpy), lower temperatures than the acid gas dew point are not advisable for metallic surfaces in contact with the gas. In municipal solid waste fired plants, in addition to sulfuric acid, one has to deal with hydrochloric and hydrobromic acid formation. This article deals with methods for solving cold, or back end corrosion as it is called, with the most commonly used heat recovery equipment, namely economizers or water heaters. These are used to preheat feed water entering the system and operate at low metal temperatures, thereby increasing their susceptibility to corrosion by sulfuric, hydrochloric, hydrobromic and carbonic acid.

  8. CORROSION INHIBITION BY CASHEW NUT SHELL LIQUID

    African Journals Online (AJOL)

    MECHANISTIC STUDIES OF CARBON STEEL. CORROSION INHIBITION BY CASHEW NUT SHELL. LIQUID. JYN Philip, J Buchweishaija and LL Mkayula. Department of Chemistry, University of Dar es Salaam,. P. O. Box 35061, Dar es Salaam, Tanzania. ABSTRACT. The inhibition mechanism of the Cashew Nut Shell ...

  9. (IV) Oxide Corrosion in Oil Exploration

    African Journals Online (AJOL)

    Sulphide and Carbon lV Oxide in Oil Wells,. B. Eng Project, University of Port Harcourt,. 1988. Farshad, F.F and Garber, J.D. ~How to increase gas well production and temper corrosion; Part3-. Petroleum Engineering international, June l993. Stanford, A. Failure Analysis Isolates production - problem Petroleum Engineering ...

  10. [Corrosion resistance of Ti-Cu alloy].

    Science.gov (United States)

    Song, Yu-Xuan; Wang, Shi-Ming

    2010-09-01

    to investigate the corrosion behavior of Ti-Cu alloy in 0.9%NaCl solution and in acidified 0.9%NaCl solution. the microstructure of Ti-Cu alloys were characterized by means of X-ray diffraction (XRD). The electrochemical behavior of Ti-Cu alloy in two solutions (namely 0.9%NaCl solution and acidified 0.9%NaCl solution) was tested. Commercial pure Ti and 316L stainless steel were used as control. Ti-Cu alloys were composed by α-Ti and Ti(2)Cu intermetallic compound. After 3500 s immersion, the open circuit potential (OCP) values of pure Ti, Ti-5Cu alloy and Ti-10Cu alloy in 0.9% NaCl solution were -188, -181 and -173 mV, respectively. In 0.9% NaCl solution with lactic acid added, the OCP values were -143, -158 and -109 mV, respectively. In potentiodynamic polarization tests, the passive current densities of pure Ti and Ti-5Cu alloys were about 20 µA/cm(2). However, 316L stainless steel experienced pitting corrosion. it was possible to establish the following relation for their corrosion resistances: pure Ti≈Ti-5Cu > Ti-10Cu > 316L stainless steel. The addition of lactic acid in the solution did not compromise the corrosion resistance of Ti-Cu alloys.

  11. Uncommon corrosion phenomena of archaeological bronze alloys

    Science.gov (United States)

    Ingo, G. M.; de Caro, T.; Riccucci, C.; Khosroff, S.

    2006-06-01

    In the framework of the EFESTUS project (funded by the European Commission, contract No. ICA3-CT-2002-10030) the corrosion products of a large number of archaeological bronze artefacts are investigated by means of the combined use of scanning electron microscopy (SEM), energy dispersive spectrometry (EDS), X-ray diffraction (XRD) and optical microscopy (OM) and tentative correlation of their nature with the chemical composition of the artefacts and the burial context is proposed. The results provide good insight into the corrosion layers and evidence in some bronze Roman coins and artefacts; the occurrence of uncommon corrosion phenomena that give rise to the formation of a yellowish-green complex chlorine-phosphate of lead (pyromorphite, (PbCl)Pb4(PO4)3) and of a gold-like thick layer of an iron and copper sulphide (chalcopyrite, CuFeS2). The micro-chemical and micro-structural results show that the coins were buried in a soil enriched in phosphorus for the accidental presence of a large amount of decomposing fragments of bones or in an anaerobic and humus rich soil where the chalcopyrite layer has been produced via the interaction between the iron of the soil, the copper of the coin and the sulphur produced by the decomposition of organic matter in an almost oxygen free environment. Finally, some unusual periodic corrosion phenomena occurring in high tin bronze mirrors found at Zama (Tunisia) are described.

  12. Spatial Nonhomogeneous Poisson Process in Corrosion Management

    NARCIS (Netherlands)

    López De La Cruz, J.; Kuniewski, S.P.; Van Noortwijk, J.M.; Guriérrez, M.A.

    2008-01-01

    A method to test the assumption of nonhomogeneous Poisson point processes is implemented to analyze corrosion pit patterns. The method is calibrated with three artificially generated patterns and manages to accurately assess whether a pattern distribution is random, regular, or clustered. The

  13. Adaptive Corrosion Protection System Using Continuous Corrosion Measurement, Parameter Extraction, and Corrective Loop

    Directory of Open Access Journals (Sweden)

    Jasbir N. Patel

    2016-01-01

    Full Text Available A simple current-sourced adaptive corrosion protection system (ACPS along with a technology to extract the protection current from the Tafel plot is presented. For reliable protection of the target metal, first, the Tafel plot of the target metal is obtained. Subsequently, a novel technique proposed in this paper is used to extract the protection current from the Tafel plot. This extracted protection current is fed to the target metal to protect the metal in the existing corrosive environment. This three-part system is adaptively used to update the required protection current to effectively protect the target metal continuously. All these functionalities are integrated in a stand-alone ACPS that effectively diagnoses the corrosion status and updates the protection parameters without any manual interaction or physical modification of the set-up to offer modularity, reliability, and cost saving. To validate the technique, a laboratory scale system is realized and tested using various metal samples and various corrosive mediums. Using the experimental system, A36 metal coupons are effectively protected with protection (inhibition efficiency of 40–100% in different corrosive mediums that can extend the life expectancy of the target metal from ~2 times to more than 100 times for the tested corrosive mediums.

  14. Microorganisms as potential corrosion inhibitors of metallic materials

    Directory of Open Access Journals (Sweden)

    Tasić Žaklina Z.

    2016-01-01

    Full Text Available Corrosion presents the destruction of materials through chemical or electrochemical interactions with their environment. Interactions between the metal surface and bacterial cells or products of their metabolic activities can lead to microbially-influenced corrosion. Also, it is known that certain microorganisms can contribute to corrosion inhibition. In accordance to that, the literature dealing with the application of different microorganisms as a potentialy corrosion inhibitors of metals is investigated. Different bacterial strains as a corrosion inhibitor of a metalic materials are examined. Further, the role of extracellular polymeric substances in corrosion behavior of metals is emphasized. Based on the data presented in this work, it can be said that inhibition efficiency depends on microorganism as well as type of metal. Also, it is presented that some bacterial species can be used as a good corrosion inhibitor instead of toxic organic compounds.

  15. CORROSION OF LEAD SHIELDING IN NUCLEAR MATERIALS PACKAGES

    Energy Technology Data Exchange (ETDEWEB)

    Subramanian, K; Kerry Dunn, K; Joseph Murphy, J

    2008-07-18

    Inspection of United States-Department of Energy (US-DOE) model 9975 nuclear materials shipping package revealed corrosion of the lead shielding that was induced by off-gas constituents from organic components in the package. Experiments were performed to determine the corrosion rate of lead when exposed to off-gas or degradation products of these organic materials. The results showed that the room temperature vulcanizing (RTV) sealant was the most corrosive organic species used in the construction of the packaging, followed by polyvinyl acetate (PVAc) glue. Fiberboard material, also used in the construction of the packaging induced corrosion to a much lesser extent than the PVAc glue and RTV sealant, and only in the presence of condensed water. The results indicated faster corrosion at temperatures higher than ambient and with condensed water. In light of these corrosion mechanisms, the lead shielding was sheathed in a stainless steel liner to mitigate against corrosion.

  16. Monitoring Techniques for Microbially Influenced Corrosion of Carbon Steel

    DEFF Research Database (Denmark)

    Hilbert, Lisbeth Rischel

    2000-01-01

    Microbially influenced corrosion (MIC) of carbon steel may occur in media with microbiological activity of especially sulphate-reducing bacteria, e.g. on pipelines buried in soil and on marine structures. MIC of carbon steel must be monitored on-line in order to provide an efficient protection...... and control the corrosion. A number of monitoring techniques is industrially used today, and the applicability and reliability of these for monitoring MIC is evaluated. Coupons and ER are recommended as necessary basic techniques even though localised corrosion rate cannot be measured. FSM measures general...... corrosion and detects localised corrosion, but the sensitivity is not high enough for monitoring initiation of pitting and small attacks. Electrochemical techniques as LPR and EIS give distorted data and unreliable corrosion rates, when biofilm and corrosion products cover the steel surface. However, EIS...

  17. Events as Power Source: Wireless Sustainable Corrosion Monitoring

    Directory of Open Access Journals (Sweden)

    Guodong Sun

    2013-12-01

    Full Text Available This study presents and implements a corrosion-monitoring wireless sensor platform, EPS (Events as Power Source, which monitors the corrosion events in reinforced concrete (RC structures, while being powered by the micro-energy released from the corrosion process. In EPS, the proposed corrosion-sensing device serves both as the signal source for identifying corrosion and as the power source for driving the sensor mote, because the corrosion process (event releases electric energy; this is a novel idea proposed by this study. For accumulating the micro-corrosion energy, we integrate EPS with a COTS (Commercial Off-The-Shelf energy-harvesting chip that recharges a supercapacitor. In particular, this study designs automatic energy management and adaptive transmitted power control polices to efficiently use the constrained accumulated energy. Finally, a set of preliminary experiments based on concrete pore solution are conducted to evaluate the feasibility and the efficacy of EPS.

  18. Events as power source: wireless sustainable corrosion monitoring.

    Science.gov (United States)

    Sun, Guodong; Qiao, Guofu; Zhao, Lin; Chen, Zhibo

    2013-12-17

    This study presents and implements a corrosion-monitoring wireless sensor platform, EPS (Events as Power Source), which monitors the corrosion events in reinforced concrete (RC) structures, while being powered by the micro-energy released from the corrosion process. In EPS, the proposed corrosion-sensing device serves both as the signal source for identifying corrosion and as the power source for driving the sensor mote, because the corrosion process (event) releases electric energy; this is a novel idea proposed by this study. For accumulating the micro-corrosion energy, we integrate EPS with a COTS (Commercial Off-The-Shelf) energy-harvesting chip that recharges a supercapacitor. In particular, this study designs automatic energy management and adaptive transmitted power control polices to efficiently use the constrained accumulated energy. Finally, a set of preliminary experiments based on concrete pore solution are conducted to evaluate the feasibility and the efficacy of EPS.

  19. Corrosion in electronics: Overview of failures and countermeasures

    DEFF Research Database (Denmark)

    Jellesen, Morten Stendahl; Verdingovas, Vadimas; Conseil, Helene

    2014-01-01

    Many field failure returns of electronics are marked as “no failure found”, yet numerous of these failures are likely due to corrosion, since corrosion related failures are not easily detected during subsequent failure analysis. In some cases failures are intermittent and occur because of service...... are described in details, e.g. flux activator related failures. Failures caused by service life conditions with high humidity and sulphur containing gaseous environments are also described. Finally it is described how the architecture of the PCBA (the placement of components) will affect its corrosion...... film and potential bias of the PCBA will eventually lead to failure caused by more easy recognisable corrosion. Typical corrosion failure types seen in electronics are galvanic corrosion, electrochemical migration, and other types of bias induced corrosion. This paper describes the most commonly used...

  20. Failure of a MEA reclaimer tube bundle due to corrosion

    Energy Technology Data Exchange (ETDEWEB)

    Shaban, H.; Abdo, M.S.E.; Lal, D.P.

    1988-08-01

    The removal of sulphur compounds from natural gas used in ammonia production is carried out by scrubbing with monoethanol amine (MEA). To avoid build up of corrosion and degradation products, a portion of the circulating MEA solution is passed through a reclaimer. This is essentially a kettle-type reboiler with a tube bundle made of 316L stainless steel. Occasional failures of the tube bundle due to pitting corrosion have been reported. It is suggested that the excessive pitting corrosion observed on the upper rows of the tube bundle could be partly due to high steam temperature but mainly due to the liquid level falling below the tubes leaving an accumulation of corrosive degradation products on the exposed surfaces, normally these corrosive products remain diluted in the MEA solution and cause little corrosion of the covered tubes. Their concentration on the dry upper layers of the hot metal tubes, however, leads to excessive corrosion. (U.K.).

  1. The effect of recasting on corrosion of DUCINOX prosthetic alloy

    Directory of Open Access Journals (Sweden)

    L. Klimek

    2009-07-01

    Full Text Available The effect of recasting, up to two times, Ni-Cr (DUCINOX prosthetic alloy on its corrosion properties was carried out. The corrosion measurements were done in deoxygenated Fusayama Meyer artificial saliva solution at temperature of 37°C. In the study following electrochemical methods were used: measurement of free corrosion potential Ecor in open circuit, measurement of polarization resistance according to Stern-Geary's method and measurement of potentiodynamic characteristic in wide range of anodic polarization. In general, it can be stated that casting number weakly influence on corrosion properties of investigated alloy. At free corrosion potential there is no monotonic dependence of corrosion parameters versus casting number. However, at extreme anodic potentials monotonic changes of corrosion parameters with increasing casting number is observed. Obtained results and drawn conclusions are partially compatible with literature data.

  2. Biocide-mediated corrosion of coiled tubing.

    Science.gov (United States)

    Sharma, Mohita; An, Dongshan; Liu, Tao; Pinnock, Tijan; Cheng, Frank; Voordouw, Gerrit

    2017-01-01

    Coiled tubing corrosion was investigated for 16 field water samples (S5 to S20) from a Canadian shale gas field. Weight loss corrosion rates of carbon steel beads incubated with these field water samples averaged 0.2 mm/yr, but injection water sample S19 had 1.25±0.07 mm/yr. S19 had a most probable number of zero acid-producing bacteria and incubation of S19 with carbon steel beads or coupons did not lead to big changes in microbial community composition. In contrast other field water samples had most probable numbers of APB of 102/mL to 107/mL and incubation of these field water samples with carbon steel beads or coupons often gave large changes in microbial community composition. HPLC analysis indicated that all field water samples had elevated concentrations of bromide (average 1.6 mM), which may be derived from bronopol, which was used as a biocide. S19 had the highest bromide concentration (4.2 mM) and was the only water sample with a high concentration of active bronopol (13.8 mM, 2760 ppm). Corrosion rates increased linearly with bronopol concentration, as determined by weight loss of carbon steel beads, for experiments with S19, with filtered S19 and with bronopol dissolved in defined medium. This indicated that the high corrosion rate found for S19 was due to its high bronopol concentration. The corrosion rate of coiled tubing coupons also increased linearly with bronopol concentration as determined by electrochemical methods. Profilometry measurements also showed formation of multiple pits on the surface of coiled tubing coupon with an average pit depth of 60 μm after 1 week of incubation with 1 mM bronopol. At the recommended dosage of 100 ppm the corrosiveness of bronopol towards carbon steel beads was modest (0.011 mm/yr). Higher concentrations, resulting if biocide is added repeatedly as commonly done in shale gas operations, are more corrosive and should be avoided. Overdosing may be avoided by assaying the presence of residual biocide by HPLC

  3. Corrosion of copper in alkaline chloride environments

    Energy Technology Data Exchange (ETDEWEB)

    King, F. [Integrity Corrosion Consulting Ltd., Calgary (Canada)

    2002-08-01

    The available literature information on the corrosion and electrochemical behaviour of copper in alkaline environments has been reviewed. The purpose of the review was to assess the impact of an alkaline plume from cementitious material on the corrosion behaviour of a copper canister in an SKB-3 type repository. The effect of the evolution of the environmental conditions within the repository have been considered, including the effects of temperature, redox conditions, pore-water salinity and pH. If the pore-water pH increases prior to the establishment of anoxic conditions, the canister surface will passivate as the pore-water pH exceeds a value of {approx} pH 9. Passivation will result from the formation of a duplex Cu{sub 2}O/Cu(OH){sub 2} film. The corrosion potential will be determined by the equilibrium potential for the Cu{sub 2}O/Cu(OH){sub 2} couple under oxic conditions, or by the Cu/Cu{sub 2}O redox couple under anoxic conditions (in the absence of sulphide). Pitting corrosion is only likely to occur early in the evolution of the repository environment, whilst the canister is still relatively cool (<40 deg C), whilst there is still O{sub 2} available to support localised corrosion, and prior to the increase in pore-water pH and salinity. The subsequent increase in canister surface temperature, pore-water pH and salinity, and decrease in O{sub 2} will make pit initiation less likely, although the canister will remain passive provided the pore-water pH is maintained above pH 9. The higher the pore-water pH, the more strongly the canister is passivated and the less likely the surface is to undergo localised attack. If the pore-water salinity increases prior to the increase in pH, there could be a period of active canister corrosion before passivation occurs.Under these circumstances, the corrosion potential will be a true mixed potential, determine by the relative kinetics of Cu dissolution as CuCl{sub 2} - and of the reduction of O{sub 2}. The development

  4. High temperature and stress corrosion cracking of 310S austenitic stainless steel in wet chloride corrosive environment

    Directory of Open Access Journals (Sweden)

    T. Pornpibunsompop

    2018-01-01

    Full Text Available High temperature corrosion and stress corrosion cracking of 310S austenitic stainless steel in wet chloride environment at a high temperature was investigated. The result showed that high temperature corrosion products mostly consisted of ferrous oxides and chromium oxides. Chloride ions attacked a chromium passive film and strongly reacted with iron and chromium. As a result of metal chlorides being volatized, tunnel of pores inside corrosion layer existed. Intergranular stress corrosion cracking was observed. The oxide originated on surface could act as a crack initiator and a crack propagation would progress along grain boundaries and particularly along tunnel of pores.

  5. Environmentally Friendly Coating Technology for Autonomous Corrosion Control

    Science.gov (United States)

    Calle, Luz M.; Li, Wenyan; Buhrow, Jerry W.; Johnsey, Marissa N.; Jolley, Scott T.; Pearman, Benjamin P.; Zhang, Xuejun; Fitzpatrick, Lilliana; Gillis, Mathew; Blanton, Michael; hide

    2016-01-01

    This work concerns the development of environmentally friendly encapsulation technology, specifically designed to incorporate corrosion indicators, inhibitors, and self-healing agents into a coating, in such a way that the delivery of the indicators and inhibitors is triggered by the corrosion process, and the delivery of self-healing agents is triggered by mechanical damage to the coating. Encapsulation of the active corrosion control ingredients allows the incorporation of desired autonomous corrosion control functions such as: early corrosion detection, hidden corrosion detection, corrosion inhibition, and self-healing of mechanical damage into a coating. The technology offers the versatility needed to include one or several corrosion control functions into the same coating.The development of the encapsulation technology has progressed from the initial proof-of-concept work, in which a corrosion indicator was encapsulated into an oil-core (hydrophobic) microcapsule and shown to be delivered autonomously, under simulated corrosion conditions, to a sophisticated portfolio of micro carriers (organic, inorganic, and hybrid) that can be used to deliver a wide range of active corrosion ingredients at a rate that can be adjusted to offer immediate as well as long-term corrosion control. The micro carriers have been incorporated into different coating formulas to test and optimize the autonomous corrosion detection, inhibition, and self-healing functions of the coatings. This paper provides an overview of progress made to date and highlights recent technical developments, such as improved corrosion detection sensitivity, inhibitor test results in various types of coatings, and highly effective self-healing coatings based on green chemistry.

  6. Internal corrosion of carbon steel piping in hot aquifers service

    Directory of Open Access Journals (Sweden)

    Simičić Miloš V.

    2011-01-01

    Full Text Available Internal corrosion of carbon steel pipelines is a major problem encountered in water service. In terms of prediction of the remaining lifetime for water pipelines based on the corrosion allowance, the three main approaches are corrosion modelling, corrosion inhibitor availability, and corrosion monitoring. In this study we used two theoretical corrosion models, CASSANDRA and NORSOK M-506 of quite different origin in order to predict uniform corrosivity of hot aquifers in eight different pipelines. Because of the varying calculation criteria for the different models, these can give very different corrosion rate predictions for the same data input. This is especially true under conditions where the formation of protective films may occur, such as at elevated temperatures. The evaluation of models was conducted by comparison using weight-loss coupons and three corrosion inhibitors were obtained from commercial suppliers. The tests were performed during the 60-day period. Even though inhibitors’ efficiencies of 98% had been achieved in laboratory testing, inhibitors’ availabilities of 85% have been used due to logistics problems and other issues. The results, given in mmpy, i.e. millimeter per year, are very consistent with NORSOK M-506 prediction. This is presumably because the model considers the effect of the formation of a passive iron carbonate film at temperatures above 80 °C and significant reduction in corrosion rate. Corrosion inhibitor A showed a better performance than inhibitors B and C in all cases but the target corrosion rates of less than 0.1 mmpy were achieved for all inhibitors. The chemical type of corrosion inhibitor A is based on quaternary amines mixed with methanol, isopropyl alcohol, xylene and ethylbenzene. Based on the obtained results the carbon steel lifetime of 30 years, provided proper inhibitors are present and 3mm corrosion allowance, can be achieved for hot aquifers service with presented water compositions.

  7. Research opportunities in corrosion science and engineering: Committee on Research Opportunities in Corrosion Science and Engineering, National Materials Advisory Board, Division on Engineering and Physical Sciences, National Research Council of the National Academies

    National Research Council Canada - National Science Library

    2011-01-01

    "[This book] identifies grand challenges for the corrosion research community, highlights research opportunities in corrosion science and engineering, and posits a national strategy for corrosion research...

  8. Parálisis cerebral Cerebral palsy

    OpenAIRE

    Jorge Malagon Valdez

    2007-01-01

    El término parálisis cerebral (PC) engloba a un gran número de síndromes neurológicos clínicos, de etiología diversa. Estos síndromes se caracterizan por tener una sintomatología común: los trastornos motores. Algunos autores prefieren manejar términos como "encefalopatía fija", "encefalopatías no evolutivas". Se mencionan la utilidad de programas de intervención temprana y métodos especiales de rehabilitación, así como el manejo de las deficiencias asociadas como la epilepsia, deficiencia me...

  9. TMS suppression of right pars triangularis, but not pars opercularis, improves naming in aphasia

    Science.gov (United States)

    Naeser, Margaret A.; Martin, Paula I.; Theoret, Hugo; Kobayashi, Masahito; Fregni, Felipe; Nicholas, Marjorie; Tormos, Jose M.; Steven, Megan S.; Baker, Errol H.; Pascual-Leone, Alvaro

    2011-01-01

    This study sought to discover if an optimum 1 cm2 area in the non-damaged right hemisphere (RH) was present, which could temporarily improve naming in chronic, nonfluent aphasia patients when suppressed with repetitive transcranial magnetic stimulation (rTMS). Ten minutes of slow, 1 Hz rTMS was applied to suppress different RH ROIs in eight aphasia cases. Picture naming and response time (RT) were examined before, and immediately after rTMS. In aphasia patients, suppression of right pars triangularis (PTr) led to significant increase in pictures named, and significant decrease in RT. Suppression of right pars opercularis (POp), however, led to significant increase in RT, but no change in number of pictures named. Eight normals named all pictures correctly; similar to aphasia patients, RT significantly decreased following rTMS to suppress right PTr, versus right POp. Differential effects following suppression of right PTr versus right POp suggest different functional roles for these regions. PMID:21864891

  10. Transcriptome profiling reveals links between ParS/ParR, MexEF-OprN, and quorum sensing in the regulation of adaptation and virulence in Pseudomonas aeruginosa.

    Science.gov (United States)

    Wang, Dongping; Seeve, Candace; Pierson, Leland S; Pierson, Elizabeth A

    2013-09-13

    The ParS/ParR two component regulatory system plays critical roles for multidrug resistance in Pseudomonas aeruginosa. It was demonstrated that in the presence of antimicrobials, ParR enhances bacterial survival by distinct mechanisms including activation of the mexXY efflux genes, enhancement of lipopolysaccharide modification through the arn operon, and reduction of the expression of oprD porin. In this study, we report on transcriptomic analyses of P. aeruginosa PAO1 wild type and parS and parR mutants growing in a defined minimal medium. Our transcriptomic analysis provides the first estimates of transcript abundance for the 5570 coding genes in P. aeruginosa PAO1. Comparative transcriptomics of P. aeruginosa PAO1 and par mutants identified a total of 464 genes regulated by ParS and ParR. Results also showed that mutations in the parS/parR system abolished expression of the mexEF-oprN operon by down-regulating the regulatory gene mexS. In addition to the known effects on drug resistance genes, transcript abundances of the quorum sensing genes (rhlIR and pqsABCDE-phnAB) were higher in both parS and parR mutants. In accordance with these results, a significant portion of the ParS/ParR regulated genes belonged to the MexEF-OprN and quorum sensing regulons. Deletion of the par genes also led to increased phenazine production and swarming motility, consistent with the up-regulation of the phenazine and rhamnolipid biosynthetic genes, respectively. Our results link the ParS/ParR two component signal transduction system to MexEF-OprN and quorum sensing systems in P. aeruginosa. These results expand our understanding of the roles of the ParS/ParR system in the regulation of gene expression in P. aeruginosa, especially in the absence of antimicrobials.

  11. CORROSION TESTING IN SIMULATED TANK SOLUTIONS

    Energy Technology Data Exchange (ETDEWEB)

    Hoffman, E.

    2010-12-09

    Three simulated waste solutions representing wastes from tanks SY-102 (high nitrate, modified to exceed guidance limits), AN-107, and AY-102 were supplied by PNNL. Out of the three solutions tested, both optical and electrochemical results show that carbon steel samples corroded much faster in SY-102 (high nitrate) than in the other two solutions with lower ratios of nitrate to nitrite. The effect of the surface preparation was not as strong as the effect of solution chemistry. In areas with pristine mill-scale surface, no corrosion occurred even in the SY-102 (high nitrate) solution, however, corrosion occurred in the areas where the mill-scale was damaged or flaked off due to machining. Localized corrosion in the form of pitting in the vapor space of tank walls is an ongoing challenge to overcome in maintaining the structural integrity of the liquid waste tanks at the Savannah River and Hanford Sites. It has been shown that the liquid waste condensate chemistry influences the amount of corrosion that occurs along the walls of the storage tanks. To minimize pitting corrosion, an effort is underway to gain an understanding of the pitting response in various simulated waste solutions. Electrochemical testing has been used as an accelerated tool in the investigation of pitting corrosion. While significant effort has been undertaken to evaluate the pitting susceptibility of carbon steel in various simulated waste solutions, additional effort is needed to evaluate the effect of liquid waste supernates from six Hanford Site tanks (AY-101, AY-102, AN-102, AN-107, SY-102 (high Cl{sup -}), and SY-102 (high nitrate)) on carbon steel. Solutions were formulated at PNNL to replicate tank conditions, and in the case of SY-102, exceed Cl{sup -} and NO{sub 3}{sup -} conditions, respectively, to provide a contrast between in and out of specification limits. The majority of previous testing has been performed on pristine polished samples. To evaluate the actual tank carbon steel

  12. Movement and equipositioning of plasmids by ParA filament disassembly

    DEFF Research Database (Denmark)

    Ringgaard, Simon; van Zon, Jeroen; Howard, Martin

    2009-01-01

    Bacterial plasmids encode partitioning (par) loci that confer stable plasmid inheritance. We showed previously that, in the presence of ParB and parC encoded by the par2 locus of plasmid pB171, ParA formed cytoskeletal-like structures that dynamically relocated over the nucleoid. Simultaneously, ...... of the plasmids. Mathematical modeling of ParA and plasmid dynamics support these interpretations. Mutational analysis supports a molecular mechanism in which the ParB/parC complex controls ParA filament depolymerization....

  13. Pratique du bloc infraclaviculaire par voie sous coracoïdienne par ...

    African Journals Online (AJOL)

    Toutefois, des efforts pour réduire le temps de réalisation, choisir la meilleure réponse motrice distale sur laquelle injecter l'anesthésique local, par une pratique plus fréquente des techniques d'ALR périphérique, sont nécessaires pour augmenter le confort des patients et le taux de succès du bloc. Mots clés: Anesthésie ...

  14. Combined pars plana vitrectomy and pars plana Baerveldt tube placement in eyes with neovascular glaucoma.

    Science.gov (United States)

    Kolomeyer, Anton M; Seery, Christopher W; Emami-Naeimi, Parisa; Zarbin, Marco A; Fechtner, Robert D; Bhagat, Neelakshi

    2015-01-01

    To describe characteristics and outcomes of combined pars plana vitrectomy and Baerveldt tube insertion procedure from 2005 to 2010 in eyes with neovascular glaucoma. Seventy-nine patients (89 eyes) with ≥2 months of follow-up were included. Outcome measures were visual acuity, intraocular pressure (IOP), number of glaucoma medications, and complications. Changes in mean logMAR visual acuity, IOP, and glaucoma medications were compared by a two-tailed t-test. Mean patient age was 69.0 years. Forty-three (54%) were male. Mean follow-up time was 19.9 months. Most common causes of neovascular glaucoma was diabetes (n = 63 [71%]) and central retinal vein occlusion (n = 21 [24%]). Eighty-six eyes (97%) underwent a 250 mm Baerveldt drainage device and 3 (3.4%) a 350 mm Baerveldt. Forty-five (51%) 20-gauge, 12 (13%) 23-gauge, and 32 (36%) 25-gauge pars plana vitrectomies were performed. Fifty-two eyes (58%) preoperatively and 23 (33%) postoperatively received intraocular injections for rubeosis and macular edema. Mean ± standard deviation logMAR visual acuity at 18-, 24-, 36-, and 48-month follow-up time points was significantly better than preoperative vision (P pars plana vitrectomy eyes. Nine eyes (10%) required return to the operating room after combined procedure, including 4 eyes (4.5%) for retinal detachment and 3 (3.4%) for high IOP due to tube occlusion. Three eyes (3.4%) developed endophthalmitis and 2 (2.2%) progressed to being pre/phthisical (none were enucleated). Combined pars plana vitrectomy and Baerveldt glaucoma shunt may be a useful procedure in reducing IOP and number of glaucoma medications in eyes with neovascular glaucoma along with stabilizing visual acuity in a majority of these eyes. Further studies are warranted to verify and expand on these findings.

  15. Doxycycline directly targets PAR1 to suppress tumor progression.

    Science.gov (United States)

    Zhong, Weilong; Chen, Shuang; Zhang, Qiang; Xiao, Ting; Qin, Yuan; Gu, Ju; Sun, Bo; Liu, Yanrong; Jing, Xiangyan; Hu, Xuejiao; Zhang, Peng; Zhou, Honggang; Sun, Tao; Yang, Cheng

    2017-03-07

    Doxycycline have been reported to exert anti-cancer activity and have been assessed as anti-cancer agents in clinical trials. However, the direct targets of doxycycline in cancer cells remain unclear. In this study, we used a chemical proteomics approach to identify the Protease-activated receptor 1 (PAR1) as a specific target of inhibition of doxycycline. Binding assays and single-molecule imaging assays were performed to confirm the inhibition of doxycycline to PAR1. The effect of doxycycline on multi-omics and cell functions were assessed based on a PAR1/thrombin model. Molecular docking and molecular dynamic simulations revealed that doxycycline interacts with key amino acids in PAR1. Mutation of PAR1 further confirmed the computation-based results. Moreover, doxycycline provides highly selective inhibition of PAR1 signaling in tumors in vitro and in vivo. Using pathological clinical samples co-stained for doxycycline and PAR1, it was found that doxycycline fluorescence intensity and PAR1 expression shown a clear positive correlation. Thus, doxycycline may be a useful targeted anti-cancer drug that should be further investigated in clinical trials.

  16. Priapisme induit par la chlorpromazine: A propos de deux cas

    African Journals Online (AJOL)

    I. Marrag

    Nous rapportons ici le cas de deux patients qui ont présenté un priapisme en concomitance avec une pres- cription de chlorpromazine .... ischémiques pourraient être induits par des médicaments dont les neuroleptiques occupent ... vie sexuelle des patients, souvent touchée par la prescription des traitements psychotropes ...

  17. Irradiation-Accelerated Corrosion of Reactor Core Materials. Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Jiao, Zhujie [Univ. of Michigan, Ann Arbor, MI (United States); Was, Gary [Univ. of Michigan, Ann Arbor, MI (United States); Bartels, David [Univ. of Notre Dame, IN (United States)

    2015-04-02

    This project aims to understand how radiation accelerates corrosion of reactor core materials. The combination of high temperature, chemically aggressive coolants, a high radiation flux and mechanical stress poses a major challenge for the life extension of current light water reactors, as well as the success of most all GenIV concepts. Of these four drivers, the combination of radiation and corrosion places the most severe demands on materials, for which an understanding of the fundamental science is simply absent. Only a few experiments have been conducted to understand how corrosion occurs under irradiation, yet the limited data indicates that the effect is large; irradiation causes order of magnitude increases in corrosion rates. Without a firm understanding of the mechanisms by which radiation and corrosion interact in film formation, growth, breakdown and repair, the extension of the current LWR fleet beyond 60 years and the success of advanced nuclear energy systems are questionable. The proposed work will address the process of irradiation-accelerated corrosion that is important to all current and advanced reactor designs, but remains very poorly understood. An improved understanding of the role of irradiation in the corrosion process will provide the community with the tools to develop predictive models for in-reactor corrosion, and to address specific, important forms of corrosion such as irradiation assisted stress corrosion cracking.

  18. The corrosive nature of manganese in drinking water

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez-Bastida, C. [Centro Interamericano de Recursos del Agua, Facultad de Ingeniería, Universidad Autónoma del Estado de México, Carretera Toluca-Ixtlahuaca, Km. 14.5, C.P. 50200, Toluca, Estado de México (Mexico); Facultad de Química, Universidad Autónoma del Estado de México, Paseo Colón y Tollocan s/n, C.P. 50000, Toluca, Estado de México (Mexico); Martínez-Miranda, V.; Vázquez-Mejía, G. [Centro Interamericano de Recursos del Agua, Facultad de Ingeniería, Universidad Autónoma del Estado de México, Carretera Toluca-Ixtlahuaca, Km. 14.5, C.P. 50200, Toluca, Estado de México (Mexico); Solache-Ríos, M., E-mail: marcos.solache@inin.gob.mx [Departamento de Química, Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, Col. Escandón, Delegación Miguel Hidalgo, C.P. 11801 México, D.F. (Mexico); Fonseca-Montes de Oca, G. [Centro Interamericano de Recursos del Agua, Facultad de Ingeniería, Universidad Autónoma del Estado de México, Carretera Toluca-Ixtlahuaca, Km. 14.5, C.P. 50200, Toluca, Estado de México (Mexico); Trujillo-Flores, E. [Facultad de Ingeniería, Universidad Autónoma del Estado de México, Cerro de Coatepec s/n, Ciudad Universitaria, C.P. 50130, Toluca, Estado de México (Mexico)

    2013-03-01

    Corrosion problems having to do with drinking water distribution systems are related to many processes and factors and two of them are ionic acidity and carbon dioxide, which were considered in this work. The corrosion character of water is determined by the corrosion indexes of Langelier, Ryznar, Larson, and Mojmir. The results show that pipes made of different materials, such as plastics or metals, are affected by corrosion, causing manganese to be deposited on materials and dissolved in water. The deterioration of the materials, the degree of corrosion, and the deposited corrosion products were determined by X-ray diffraction and Scanning Electron Microscopy. High levels of manganese and nitrate ions in water may cause serious damage to the health of consumers of water. Three wells were examined, one of them presented a high content of manganese; the others had high levels of nitrate ions, which increased the acidity of the water and, therefore, the amount of corrosion of the materials in the distribution systems. - Highlights: ► Corrosion of distribution systems affects the quality of drinking water. ► Corrosion in water distribution systems is related to acidity and carbon dioxide. ► Pipes are corroded and manganese is deposited on pipes and dissolved in water. ► The deterioration of the pipes and the corrosion products were determined. ► Nitrate ions increase the acidity of water in the wells.

  19. Corrosion behavior of Mg/graphene composite in aqueous electrolyte

    Energy Technology Data Exchange (ETDEWEB)

    Selvam, M. [Centre for Nano Science and Technology, KS Rangasamy College of Technology, Tiruchengode, 637215, Tamil Nadu (India); Saminathan, K., E-mail: ksaminath@gmail.com [Centre for Nano Science and Technology, KS Rangasamy College of Technology, Tiruchengode, 637215, Tamil Nadu (India); Siva, P. [Centre for Nano Science and Technology, KS Rangasamy College of Technology, Tiruchengode, 637215, Tamil Nadu (India); Saha, P. [Department of Ceramic Engineering, National Institute of Technology, Rourkela, India-769008 (India); Rajendran, V. [Centre for Nano Science and Technology, KS Rangasamy College of Technology, Tiruchengode, 637215, Tamil Nadu (India)

    2016-04-01

    In the present work, the electrochemical corrosion behavior of magnesium (Mg) and thin layer graphene coated Mg (Mg/graphene) are studied in different salt electrolyte such as NaCl, KCl and Na{sub 2}SO{sub 4}. The phase structure, crystallinity, and surface morphology of the samples are investigated using X-ray diffraction (XRD) analysis, scanning electron microscopy coupled with energy dispersive X-ray analysis (SEM/EDAX), and Raman spectroscopy techniques. The electrochemical corrosion behavior of the Mg and graphene coated Mg are also investigated using Electrochemical Impedance Spectroscopy (EIS) analysis. The tafel plot reveals that the corrosion of Mg drastically drops when coated with thin layer graphene (Mg/graphene) compared to Mg in KCl electrolyte. Moreover, the EIS confirms that Mg/graphene sample shows improve corrosion resistance and lower corrosion rate in KCl solution compare to all other electrolytes studied in the present system. - Highlights: • The corrosion behavior of magnesium alloy (AZ91) was investigated in three different electrolyte solution. • To study the anti-corrosion behavior of graphene coated with magnesium alloy. • To improve the corrosion resistance for magnesium alloy. • Nyquist plots confirms that MgG shows better corrosion resistance and lower corrosion rate in KCl solution.

  20. Dual Use Corrosion Inhibitor and Penetrant for Anomaly Detection in Neutron/X Radiography

    Science.gov (United States)

    Hall, Phillip B. (Inventor); Novak, Howard L. (Inventor)

    2004-01-01

    A dual purpose corrosion inhibitor and penetrant composition sensitive to radiography interrogation is provided. The corrosion inhibitor mitigates or eliminates corrosion on the surface of a substrate upon which the corrosion inhibitor is applied. In addition, the corrosion inhibitor provides for the attenuation of a signal used during radiography interrogation thereby providing for detection of anomalies on the surface of the substrate.

  1. 49 CFR 195.589 - What corrosion control information do I have to maintain?

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false What corrosion control information do I have to... SAFETY TRANSPORTATION OF HAZARDOUS LIQUIDS BY PIPELINE Corrosion Control § 195.589 What corrosion control... sufficient detail to demonstrate the adequacy of corrosion control measures or that corrosion requiring...

  2. Bacterial mitosis: partitioning protein ParA oscillates in spiral-shaped structures and positions plasmids at mid-cell

    DEFF Research Database (Denmark)

    Ebersbach, Gitte; Gerdes, Kenn; Charbon, Gitte Ebersbach

    2004-01-01

    The par2 locus of Escherichia coli plasmid pB171 encodes oscillating ATPase ParA, DNA binding protein ParB and two cis-acting DNA regions to which ParB binds (parC1 and parC2). Three independent techniques were used to investigate the subcellular localization of plasmids carrying par2. In cells w...

  3. ParABS system in chromosome partitioning in the bacterium Myxococcus xanthus.

    Directory of Open Access Journals (Sweden)

    Antonio A Iniesta

    Full Text Available Chromosome segregation is an essential cellular function in eukaryotic and prokaryotic cells. The ParABS system is a fundamental player for a mitosis-like process in chromosome partitioning in many bacterial species. This work shows that the social bacterium Myxococcus xanthus also uses the ParABS system for chromosome segregation. Its large prokaryotic genome of 9.1 Mb contains 22 parS sequences near the origin of replication, and it is shown here that M. xanthus ParB binds preferentially to a consensus parS sequence in vitro. ParB and ParA are essential for cell viability in M. xanthus as in Caulobacter crescentus, but unlike in many other bacteria. Absence of ParB results in anucleate cells, chromosome segregation defects and loss of viability. Analysis of ParA subcellular localization shows that it clusters at the poles in all cells, and in some, in the DNA-free cell division plane between two chromosomal DNA masses. This ParA localization pattern depends on ParB but not on FtsZ. ParB inhibits the nonspecific interaction of ParA with DNA, and ParA colocalizes with chromosomal DNA only when ParB is depleted. The subcellular localization of ParB suggests a single ParB-parS complex localized at the edge of the nucleoid, next to a polar ParA cluster, with a second ParB-parS complex migrating after the replication of parS takes place to the opposite nucleoid edge, next to the other polar ParA cluster.

  4. Recombination in the human Pseudoautosomal region PAR1.

    Directory of Open Access Journals (Sweden)

    Anjali G Hinch

    2014-07-01

    Full Text Available The pseudoautosomal region (PAR is a short region of homology between the mammalian X and Y chromosomes, which has undergone rapid evolution. A crossover in the PAR is essential for the proper disjunction of X and Y chromosomes in male meiosis, and PAR deletion results in male sterility. This leads the human PAR with the obligatory crossover, PAR1, to having an exceptionally high male crossover rate, which is 17-fold higher than the genome-wide average. However, the mechanism by which this obligatory crossover occurs remains unknown, as does the fine-scale positioning of crossovers across this region. Recent research in mice has suggested that crossovers in PAR may be mediated independently of the protein PRDM9, which localises virtually all crossovers in the autosomes. To investigate recombination in this region, we construct the most fine-scale genetic map containing directly observed crossovers to date using African-American pedigrees. We leverage recombination rates inferred from the breakdown of linkage disequilibrium in human populations and investigate the signatures of DNA evolution due to recombination. Further, we identify direct PRDM9 binding sites using ChIP-seq in human cells. Using these independent lines of evidence, we show that, in contrast with mouse, PRDM9 does localise peaks of recombination in the human PAR1. We find that recombination is a far more rapid and intense driver of sequence evolution in PAR1 than it is on the autosomes. We also show that PAR1 hotspot activities differ significantly among human populations. Finally, we find evidence that PAR1 hotspot positions have changed between human and chimpanzee, with no evidence of sharing among the hottest hotspots. We anticipate that the genetic maps built and validated in this work will aid research on this vital and fascinating region of the genome.

  5. Megestrol acetate NCD oral suspension--Par Pharmaceutical: megestrol acetate nanocrystal dispersion oral suspension, PAR 100.2, PAR-100.2.

    Science.gov (United States)

    2007-01-01

    Par Pharmaceutical has developed megestrol acetate (Megace ES) oral suspension for the treatment of anorexia, cachexia and a significant weight loss associated with AIDS. Par Pharmaceutical used Elan Corporation's NanoCrystal Dispersion (NCD) technology to develop an advanced, concentrated formulation of megestrol acetate with improved bioavailability, more rapid onset of action, more convenient dosing and a lower dosing regimen compared with the original marketed formulation of megestrol acetate oral suspension. Patients are administered a teaspoon (5mL) of the new NCD formulation once daily, compared with a daily 20mL dosage cup of the original formulation. The new megestrol acetate NCD formulation represents a line-extension of Par's megestrol acetate oral suspension (800mg/20mL, Megace O/S) that has been marketed for anorexia, cachexia and AIDS-related weight loss since July 2001. Par's megestrol acetate is the generic version of Bristol-Myers Squibb's Megace Oral Suspension. NanoCrystal Dispersion (NCD) is a trademark of Elan Corporation. Par Pharmaceutical will market megestol acetate NCD oral suspension under the Megace brand name. The company licensed the Megace name from Bristol-Myers Squib in August 2003. The US FDA approved megestrol acetate oral suspension (625 mg/mL) in July 2005 for the treatment of anorexia, cachexia or a significant, unexplained weight loss in patients with AIDS. The NDA for the product was accepted for review by the agency in September 2004, following its submission in June of that year.Par Pharmaceutical commenced the first of two phase III clinical trials of megestrol acetate oral suspension (PAR 100.2) in cancer-induced anorexia in the first quarter of 2006. However, this trial was discontinued in September 2006 because of slow patient enrolment. The company intends to discuss future development options in this indication with the FDA.New formulations or dosage forms of megestrol acetate concentrated suspension are also in

  6. Prévision des cinétiques de propagation de défauts de corrosion affectant les structures en alliage d'aluminium 2024

    OpenAIRE

    Augustin, Christel

    2008-01-01

    La sensibilité à la corrosion intergranulaire est influencée par trois paramètres majeurs : l'état métallurgique du matériau, les paramètres physiques et chimiques caractéristiques de l'environnement extérieur et l'état de contrainte du matériau. La première partie des travaux est consacrée à la détermination de paramètres pertinents de description de la corrosion intergranulaire. Un nouveau protocole basé sur l'abattement des propriétés mécaniques du matériau corrodé a donc été mis en place....

  7. Effects of thrombin, PAR-1 activating peptide and a PAR-1 antagonist on umbilical artery resistance in vitro

    Directory of Open Access Journals (Sweden)

    Elliott John T

    2005-02-01

    Full Text Available Abstract Background The non-thrombotic effects of thrombin in cardiovascular tissues, as mediated via the protease activated receptors (PARs, and particularly PAR-1, have been the focus of much recent research. The aims of this study were to evaluate the effects of thrombin, a specific PAR-1 activating peptide (PAR1-AP, and a PAR-1 antagonist on human umbilical artery tone in vitro. Methods Human umbilical artery samples were obtained from 17 women at term. Arterial rings were suspended under physiologic conditions for isometric recording. The in vitro effects of thrombin (0.5 units/mL to 3 units/mL, PAR1-AP TFLLR-NH2 [10(-9 to 10(-6 M], and PAR-1 antagonist (N-trans cinnamoyl- p-fluoroPhe-p-guanidinoPhe-Leu-Arg-Orn-NH2 [10(-9 M to 10(-5 M] on umbilical artery tone were measured. Results Both thrombin and TFLLR-NH2 exerted a potent cumulative vasodilatory effect on human umbilical artery resistance (P 0.05. Conclusion These findings highlight a potential role for thrombin and PAR-1 receptors in vascular regulation of feto-placental blood flow in normal pregnancy, and in association with the vascular lesions associated with IUGR and pre-eclampsia.

  8. IGF-II receptors in luminal and basolateral membranes isolated from pars convoluta and pars recta of rabbit proximal tubule

    DEFF Research Database (Denmark)

    Jacobsen, Christian; Jessen, H; Flyvbjerg, A

    1995-01-01

    The binding of 125I-labeled insulin-like growth factor-II (125I-IGF-II) to luminal and basolateral membrane vesicles isolated from pars convoluta and the straight part (pars recta) of rabbit proximal tubule was investigated. Analyses of the binding data by use of the general stoichiometric bindin...

  9. Study on corrosion of steels in marine environment by corrosion simulation device

    Energy Technology Data Exchange (ETDEWEB)

    Xiang, B.; Zhang, J.; Duan, J.Z. [Institute of Oceanology, Chinese Academy of Sciences, 7 Nanhai Road, Qingdao, 266071 (China); Hou, B.R. [Graduate School, Chinese Academy of Sciences, Beijing, 100039 (China)

    2003-09-01

    Three kinds of steels were studied using electrically connected hanging specimen in the corrosion simulation device and offshore long scale hanging specimen. The experimental results obtained by the two methods show that the device can better reflect the offshore corrosion environment. A Ni-Cu-P steel specimen was studied through analysis of the specimen's corrosion products and corrosion types. The surface of the samples before and after the removal of the rust layer produced by these two methods were observed and compared after some experiments. The microstructure of the corrosion products under different marine environments were analyzed and compared through IR. It indicated good correlation between the electrically connected hanging specimen method and the long scale hanging specimen method. (Abstract Copyright [2003], Wiley Periodicals, Inc.) [German] Mit Hilfe einer Korrosionssimulationsvorrichtung wurden drei Staehle untersucht, wobei haengende Proben im Grossmassstab verwendet wurden. Korrosionsarten und Korrosionsprodukte einer Ni-Cu-P-Stahlprobe wurden analysiert. Das Aussehen von zwei Methoden der Probenauslagerung und die Oberflaeche des metallischen Substrates nach der Entfernung der Rostschicht wurden beobachtet und bewertet. Die Phasenstruktur der Korrosionsprodukte unter verschiedenen marinen Umgebungen wurde analysiert und verglichen. Es zeigte sich eine gute Uebereinstimmung zwischen den zwei Methoden der Probenauslagerung. (Abstract Copyright [2003], Wiley Periodicals, Inc.)

  10. A new corrosion sensor to determine the start and development of embedded rebar corrosion process at coastal concrete.

    Science.gov (United States)

    Xu, Chen; Li, Zhiyuan; Jin, Weiliang

    2013-09-30

    The corrosion of reinforcements induced by chloride has resulted to be one of the most frequent causes of their premature damage. Most corrosion sensors were designed to monitor corrosion state in concrete, such as Anode-Ladder-System and Corrowatch System, which are widely used to monitor chloride ingress in marine concrete. However, the monitoring principle of these corrosion sensors is based on the macro-cell test method, so erroneous information may be obtained, especially from concrete under drying or saturated conditions due to concrete resistance taking control in macro-cell corrosion. In this paper, a fast weak polarization method to test corrosion state of reinforcements based on electrochemical polarization dynamics was proposed. Furthermore, a new corrosion sensor for monitoring the corrosion state of concrete cover was developed based on the proposed test method. The sensor was tested in cement mortar, with dry-wet cycle tests to accelerate the chloride ingress rate. The results show that the corrosion sensor can effectively monitor chloride penetration into concrete with little influence of the relative humidity in the concrete. With a reasonable corrosion sensor electrode arrangement, it seems the Ohm-drop effect measured by EIS can be ignored, which makes the tested electrochemical parameters more accurate.

  11. A New Corrosion Sensor to Determine the Start and Development of Embedded Rebar Corrosion Process at Coastal Concrete

    Directory of Open Access Journals (Sweden)

    Weiliang Jin

    2013-09-01

    Full Text Available The corrosion of reinforcements induced by chloride has resulted to be one of the most frequent causes of their premature damage. Most corrosion sensors were designed to monitor corrosion state in concrete, such as Anode-Ladder-System and Corrowatch System, which are widely used to monitor chloride ingress in marine concrete. However, the monitoring principle of these corrosion sensors is based on the macro-cell test method, so erroneous information may be obtained, especially from concrete under drying or saturated conditions due to concrete resistance taking control in macro-cell corrosion. In this paper, a fast weak polarization method to test corrosion state of reinforcements based on electrochemical polarization dynamics was proposed. Furthermore, a new corrosion sensor for monitoring the corrosion state of concrete cover was developed based on the proposed test method. The sensor was tested in cement mortar, with dry-wet cycle tests to accelerate the chloride ingress rate. The results show that the corrosion sensor can effectively monitor chloride penetration into concrete with little influence of the relative humidity in the concrete. With a reasonable corrosion sensor electrode arrangement, it seems the Ohm-drop effect measured by EIS can be ignored, which makes the tested electrochemical parameters more accurate.

  12. A New Corrosion Sensor to Determine the Start and Development of Embedded Rebar Corrosion Process at Coastal Concrete

    Science.gov (United States)

    Xu, Chen; Li, Zhiyuan; Jin, Weiliang

    2013-01-01

    The corrosion of reinforcements induced by chloride has resulted to be one of the most frequent causes of their premature damage. Most corrosion sensors were designed to monitor corrosion state in concrete, such as Anode-Ladder-System and Corrowatch System, which are widely used to monitor chloride ingress in marine concrete. However, the monitoring principle of these corrosion sensors is based on the macro-cell test method, so erroneous information may be obtained, especially from concrete under drying or saturated conditions due to concrete resistance taking control in macro-cell corrosion. In this paper, a fast weak polarization method to test corrosion state of reinforcements based on electrochemical polarization dynamics was proposed. Furthermore, a new corrosion sensor for monitoring the corrosion state of concrete cover was developed based on the proposed test method. The sensor was tested in cement mortar, with dry-wet cycle tests to accelerate the chloride ingress rate. The results show that the corrosion sensor can effectively monitor chloride penetration into concrete with little influence of the relative humidity in the concrete. With a reasonable corrosion sensor electrode arrangement, it seems the Ohm-drop effect measured by EIS can be ignored, which makes the tested electrochemical parameters more accurate. PMID:24084117

  13. Comparative Stress Corrosion Cracking and General Corrosion Resistance of Annealed and Hardened 440 C Stainless Steel - New Techniques in Stress Corrosion Testing

    Science.gov (United States)

    Mendreck, M. J.; Hurless, B. E.; Torres, P. D.; Danford, M. D.

    1998-01-01

    The corrosion and stress corrosion cracking (SCC) characteristics of annealed and hardened 440C stainless steel were evaluated in high humidity and 3.5-percent NaCl solution. Corrosion testing consisted of an evaluation of flat plates, with and without grease, in high humidity, as well as electrochemical testing in 3.5-percent NaCl. Stress corrosion testing consisted of conventional, constant strain, smooth bar testing in high humidity in addition to two relatively new techniques under evaluation at MSFC. These techniques involve either incremental or constant rate increases in the load applied to a precracked SE(B) specimen, monitoring the crack-opening-displacement response for indications of crack growth. The electrochemical corrosion testing demonstrated an order of magnitude greater general corrosion rate in the annealed 440C. All techniques for stress corrosion testing showed substantially better SCC resistance in the annealed material. The efficacy of the new techniques for stress corrosion testing was demonstrated both by the savings in time and the ability to better quantify SCC data.

  14. Corrosion of Metal Modular Cup Liners.

    Science.gov (United States)

    Hothi, Harry S; Ilo, Kevin; Whittaker, Robert K; Eskelinen, Antti; Skinner, John A; Hart, Alister J

    2015-09-01

    Numerous studies have reported on corrosion at the modular head taper, however less is known about the interface between the metal shell and liner of modular cups. This study examined the backside of a series of metal modular cup liners of two designs (DePuy Pinnacle and Smith & Nephew R3), retrieved from 67 patients. Visual inspection found evidence of corrosion in virtually all liners, with the engaging rim surface significantly more corroded than the polar regions (Pcorrosion debris, while SEM analysis revealed considerable pitting in the vicinity of the black debris. The R3 liners were significantly more corroded that the Pinnacles (P<0.001); this may help to explain the higher revision rates of this design. Copyright © 2015. Published by Elsevier Inc.

  15. Corrosive injuries of the upper gastrointestinal tract

    Directory of Open Access Journals (Sweden)

    Babu Lal Meena

    2017-01-01

    Full Text Available Corrosive injury of the upper gastrointestinal tract is a worldwide clinical problem, mostly occurring in children. Alkaline agents produce deeper injuries whereas acidic agents produce superficial injuries usually. Hoarseness, stridor, and respiratory distress indicate airway injury. Dysphagia, odynophagia, and drooling of saliva suggest esophageal injury whereas abdominal pain, nausea, and vomiting are indicative of stomach injury. X-rays should be done to rule out perforation. Endoscopy is usually recommended in the first 12–48 h although it is safe up to 96 h after caustic ingestion. Endoscopy should be performed with caution and gentle insufflation. Initial management includes getting intravenous access and replacement of fluids. Hyperemia and superficial ulcerations have excellent recovery while deeper injuries require total parenteral nutrition or feeding jejunostomy. Patients suspected of perforation should be subjected to laparotomy. Common complications after corrosive injury are esophageal stricture, gastric outlet obstruction, and development of esophageal and gastric carcinoma.

  16. Zinc-The key to preventing corrosion

    Science.gov (United States)

    Kropschot, S.J.; Doebrich, Jeff L.

    2011-01-01

    Centuries before it was identified as an element, zinc was used to make brass (an alloy of zinc and copper) and for medicinal purposes. Metallic zinc and zinc oxide were produced in India sometime between the 11th and 14th centuries and in China in the 17th century, although the discovery of pure metallic zinc is credited to the German chemist Andreas Marggraf, who isolated the element in 1746. Refined zinc metal is bluish-white when freshly cast; it is hard and brittle at most temperatures and has relatively low melting and boiling points. Zinc alloys readily with other metals and is chemically active. On exposure to air, it develops a thin gray oxide film (patina), which inhibits deeper oxidation (corrosion) of the metal. The metal's resistance to corrosion is an important characteristic in its use.

  17. Lamb Wave Tomography for Corrosion Mapping

    Science.gov (United States)

    Hinders, Mark K.; McKeon, James C. P.

    1999-01-01

    As the world-wide civil aviation fleet continues to age, methods for accurately predicting the presence of structural flaws-such as hidden corrosion-that compromise airworthiness become increasingly necessary. Ultrasonic guided waves, Lamb waves, allow large sections of aircraft structures to be rapidly inspected. However, extracting quantitative information from Lamb wave data has always involved highly trained personnel with a detailed knowledge of mechanical-waveguide physics. Our work focuses on using a variety of different tomographic reconstruction techniques to graphically represent the Lamb wave data in images that can be easily interpreted by technicians. Because the velocity of Lamb waves depends on thickness, we can convert the travel times of the fundamental Lamb modes into a thickness map of the inspection region. In this paper we show results for the identification of single or multiple back-surface corrosion areas in typical aluminum aircraft skin structures.

  18. Nitrocarburizing for wear, corrosion, and fatigue

    Energy Technology Data Exchange (ETDEWEB)

    Wahl, G. [Durferrit GmbH Thermotechnik, Hanau (Germany)

    1996-04-01

    Demands for higher strength and corrosion resistance at higher temperatures cannot always be met by advanced materials and designs alone. In many cases, surface engineering can provide required properties and extend service life. A thermochemical surface engineering treatment has been developed that improves the dynamic strength of parts and overcomes many corrosion and wear problems. Known as Melonite, the process was developed by Durferrite GmbH Thermotechnik, and is used to enhance the surface properties of steel and iron parts. The quench, quench-polish, and quench-polish-quench salt bath nitrocarburizing system can provide surface layers with a range of beneficial properties. This article will discuss details of the Melonite process, component properties after treatment, the effects of raising or lowering treatment temperatures, and environmental impact.

  19. Corrosion Study Using Electrochemical Impedance Spectroscopy

    Science.gov (United States)

    Farooq, Muhammad Umar

    2003-01-01

    Corrosion is a common phenomenon. It is the destructive result of chemical reaction between a metal or metal alloy and its environment. Stainless steel tubing is used at Kennedy Space Center for various supply lines which service the orbiter. The launch pads are also made of stainless steel. The environment at the launch site has very high chloride content due to the proximity to the Atlantic Ocean. Also, during a launch, the exhaust products in the solid rocket boosters include concentrated hydrogen chloride. The purpose of this project was to study various alloys by Electrochemical Impedance Spectroscopy in corrosive environments similar to the launch sites. This report includes data and analysis of the measurements for 304L, 254SMO and AL-6XN in primarily neutral 3.55% NaCl. One set of data for 304L in neutral 3.55%NaCl + 0.1N HCl is also included.

  20. Photoelectrochemical Corrosion of Semiconductors for Solar Cells

    Science.gov (United States)

    Madou, M. J.; Frese, K. W.; Morrison, S. R.

    1980-11-01

    Experimental results on stabilization against photo-induced corrosion of n-Si and n-GaAs in contact with electrolytes are given. Photocorrosion is examined on silicon using voltammetry on GaAs using a rotating ring-disk technique. The most extensive testing of stability was done for n-Si in a solution of N,N,N',N'-tetramethyl-p-phenvlenediamine in methanol and for n-GaAs in an aqueous solution of Fe(II) EDTA. Multiple waves were observed for the oxidation of several organic compounds on illuminated n-Si. To explain this auasi-metallic behavior a model based on an intervening thin surface oxide is postulated. In the case of n-GaAs the influence of mechanical surface damage, pH of the solution and redox couple used was studied. It is found that surface defects areativ enhance the susceptibility of the GaAs to photo-induced corrosion.

  1. Corrosion resistance improvement of titanium base alloys

    Directory of Open Access Journals (Sweden)

    Mihai V. Popa

    2010-01-01

    Full Text Available The corrosion resistance of the new Ti-6Al-4V-1Zr alloy in comparison with ternary Ti-6Al-4V alloy in Ringer-Brown solution and artificial Carter-Brugirard saliva of different pH values was studied. In Ringer-Brown solution, the new alloy presented an improvement of all electrochemical parameters due to the alloying with Zr; also, impedance spectra revealed better protective properties of its passive layer. In Carter-Brugirard artificial saliva, an increase of the passive film thickness was proved. Fluoride ions had a slight negative influence on the corrosion and ion release rates, without to affect the very good stability of the new Ti-6Al-4V-1Zr alloy.

  2. Corrosion Evaluation of Aircraft Depainting Chemicals

    Science.gov (United States)

    McGill, Preston; Torres, Pablo

    1999-01-01

    The National Aeronautics and Space Administration is participating in an interagency task agreement with the Environmental Protection Agency and the United States Air Force to evaluate alternative technologies for aerospace depainting operations that do not adversely affect the environment. An element of this study is directed towards the evaluation of environmentally advantaged chemical paint strippers, specifically, paint strippers that do not contain methylene chloride. Eight environmentally advantaged, or alternative, chemical paint strippers and two methylene chloride, or baseline, paint strippers were obtained from various manufacturers and incorporated into the depainting study. In addition to being evaluated on their ability to remove paint, the potential of these chemicals to promote corrosion and hydrogen embrittlement was evaluated. The corrosion and hydrogen embrittlement potential of the chemical paint strippers are presented in this report.

  3. Stress-corrosion cracking of titanium alloys.

    Science.gov (United States)

    Blackburn, M. J.; Feeney, J. A.; Beck, T. R.

    1973-01-01

    In the light of research material published up to May 1970, the current understanding of the experimental variables involved in the stress-corrosion cracking (SCC) behavior of titanium and its alloys is reviewed. Following a brief summary of the metallurgy and electrochemistry of titanium alloys, the mechanical, electrochemical, and metallurgical parameters influencing SCC behavior are explored with emphasis on crack growth kinetics. Macro- and microfeatures of fractures are examined, and it is shown that many transgranular SCC failures exhibit morphological and crystallographic features similar to mechanical cleavage failures. Current SCC models are reviewed with respect to their ability to explain the observed SCC behavior of titanium and its alloys. Possible methods for eliminating or minimizing stress corrosion hazards in titanium or titanium alloy components are described.

  4. Pitting corrosion resistant austenite stainless steel

    Science.gov (United States)

    van Rooyen, D.; Bandy, R.

    A pitting corrosion resistant austenite stainless steel comprises 17 to 28 wt. % chromium, 15 to 26 wt. % nickel, 5 to 8 wt. % molybdenum, and 0.3 to 0.5 wt. % nitrogen, the balance being iron, unavoidable impurities, minor additions made in the normal course of melting and casting alloys of this type, and may optionally include up to 10 wt. % of manganese, up to 5 wt. % of silicon, and up to 0.08 wt. % of carbon.

  5. RESEARCH OF FRUIT CONSERVES’ CORROSIVE AGGRESSIVENESS

    OpenAIRE

    I. Kuznecova; K. Janchenko

    2017-01-01

    Corrosion of metal canning containers is one of the obstacles in spreading its application for packing of food. Particularly aggressive to the metal container is fruit canned medium, containing organic acids.The basic material for the production of metal canning container is white tinplate. The main advantage of white tinplate is the tin compounds are harmless to human organism. For this reason, a white badge is used widely, usually used for production of canning containers, packaging beverag...

  6. Fundamental aspects of high-temperature corrosion

    OpenAIRE

    Rapp, Robert

    1993-01-01

    Some recent considerations in three widely different aspects of high-temperature corrosion are summarized: 1) reactions at the metal/scale interface in support of scale growth; 2) mass transfer effects in the control of evaporation of volatile reaction products; and 3) the codeposition of multiple elements for diffusion coatings using halide-activated cementation packs. The climb of misfit edge dislocations from the metal/scale interface can achieve the annihilation of vacancies associated wi...

  7. Corrosion of galvanized pipes in the hot water supply system

    Directory of Open Access Journals (Sweden)

    Andrianov Alexey

    2017-01-01

    Full Text Available The paper describes the problem of steel pipes corrosion in domestic hot water supply systems. A case study of abnormally high rate of corrosion of galvanized steel pipes in a hot water supply system, installed in a complex of residential and public buildings, was considered. The rapid corrosion led to premature failure of these pipelines. Onsite visual inspection, chemical analysis of the tap water with LSI/RSI calculation and scanning electron microscopy and energy-dispersive X-ray spectroscopy analysis were used during this study. The basic factors that lead to pitting corrosion were established: quality of source water (its high corrosion activity, high temperature and local increase in oxygen content near the pipe surface. A possibility of microbial corrosion was also assumed.

  8. Localized corrosion information using high resolution measurement devices

    DEFF Research Database (Denmark)

    Ambat, Rajan

    2005-01-01

    High performance demand for several engineering alloys and components, and miniaturization of electronics and development of MEMS requires better understanding of local corrosion characteristics frequently down to µm scale. This is because in metallic materials corrosion is a sensitive function...... in conjunction with microstructural analysis, using advanced microscopic tools, becomes very important. Corrosion of microelectronics circuits and MEMs is also a recent problem, which demands measurement resolution down to few microns as the components are extremely small, and measurement needs to be carried out...... of the technique could be further enhanced by adding new features such as high resolution video visualization systems, fretting/tribo-corroson attachments, and also by integrating it with stress corrosion testing, corrosion investigation of concrete for a few to name with. The corrosion group in MPT, Technical...

  9. Non-destructive elecrochemical monitoring of reinforcement corrosion

    DEFF Research Database (Denmark)

    Nygaard, Peter Vagn

    been widely accepted as a non-destructive ”state of the art” technique for detection of corrosion in concrete structures. And, over the last decade, the trend in corrosion monitoring has moved towards quantitative non-destructive monitoring of the corrosion rate of the steel reinforcement. A few...... corrosion rate measurement instruments have been developed and are commercially available. The main features of these instruments are the combined use of an electrochemical technique for determining the corrosion rate and a so-called ”confinement technique”, which in principle controls the polarised surface...... area of the reinforcement, i.e. the measurement area. Both on-site investigations and laboratory studies have shown that varying corrosion rates are obtained when the various commercially available instruments are used. And in the published studies, conflicting explanations are given illustrating...

  10. Monitoring Techniques for Microbially Influenced Corrosion of Carbon Steel

    DEFF Research Database (Denmark)

    Hilbert, Lisbeth Rischel

    2000-01-01

    of carbon steel must be monitored on-line in order to provide an efficient protection and control the corrosion. A number of monitoring techniques is industrially used today, and the applicability and reliability of these for monitoring MIC is evaluated. Coupons and ER are recommended as necessary basic......Abstract Monitoring Techniques for Microbially Influenced Corrosion of Carbon Steel Microbially influenced corrosion (MIC) of carbon steel may occur in media with microbiological activity of especially sulphate-reducing bacteria, e.g. on pipelines buried in soil and on marine structures. MIC...... techniques even though localised corrosion rate cannot be measured. FSM measures general corrosion and detects localised corrosion, but the sensitivity is not high enough for monitoring initiation of pitting and small attacks. Electrochemical techniques as LPR and EIS give distorted data and unreliable...

  11. Corrosion resistance of high-performance materials titanium, tantalum, zirconium

    CERN Document Server

    2012-01-01

    Corrosion resistance is the property of a material to resist corrosion attack in a particular aggressive environment. Although titanium, tantalum and zirconium are not noble metals, they are the best choice whenever high corrosion resistance is required. The exceptionally good corrosion resistance of these high–performance metals and their alloys results from the formation of a very stable, dense, highly adherent, and self–healing protective oxide film on the metal surface. This naturally occurring oxide layer prevents chemical attack of the underlying metal surface. This behavior also means, however, that high corrosion resistance can be expected only under neutral or oxidizing conditions. Under reducing conditions, a lower resistance must be reckoned with. Only very few inorganic and organic substances are able to attack titanium, tantalum or zirconium at ambient temperature. As the extraordinary corrosion resistance is coupled with an excellent formability and weldability these materials are very valua...

  12. Corrosion Inhibition of High Speed Steel by Biopolymer HPMC Derivatives

    Directory of Open Access Journals (Sweden)

    Shih-Chen Shi

    2016-07-01

    Full Text Available The corrosion inhibition characteristics of the derivatives of biopolymer hydroxypropyl methylcellulose (HPMC, hydroxypropyl methylcellulose phthalate (HPMCP, and hydroxypropyl methylcellulose acetate succinate (HPMCAS film are investigated. Based on electrochemical impedance spectroscopic measurements and potentiodynamic polarization, the corrosion inhibition performance of high speed steel coated with HPMC derivatives is evaluated. The Nyquist plot and Tafel polarization demonstrate promising anti-corrosion performance of HPMC and HPMCP. With increasing film thickness, both materials reveal improvement in corrosion inhibition. Moreover, because of a hydrophobic surface and lower moisture content, HPMCP shows better anti-corrosion performance than HPMCAS. The study is of certain importance for designing green corrosion inhibitors of high speed steel surfaces by the use of biopolymer derivatives.

  13. Prediction of Corrosion of Advanced Materials and Fabricated Components

    Energy Technology Data Exchange (ETDEWEB)

    A. Anderko; G. Engelhardt; M.M. Lencka (OLI Systems Inc.); M.A. Jakab; G. Tormoen; N. Sridhar (Southwest Research Institute)

    2007-09-29

    The goal of this project is to provide materials engineers, chemical engineers and plant operators with a software tool that will enable them to predict localized corrosion of process equipment including fabricated components as well as base alloys. For design and revamp purposes, the software predicts the occurrence of localized corrosion as a function of environment chemistry and assists the user in selecting the optimum alloy for a given environment. For the operation of existing plants, the software enables the users to predict the remaining life of equipment and help in scheduling maintenance activities. This project combined fundamental understanding of mechanisms of corrosion with focused experimental results to predict the corrosion of advanced, base or fabricated, alloys in real-world environments encountered in the chemical industry. At the heart of this approach is the development of models that predict the fundamental parameters that control the occurrence of localized corrosion as a function of environmental conditions and alloy composition. The fundamental parameters that dictate the occurrence of localized corrosion are the corrosion and repassivation potentials. The program team, OLI Systems and Southwest Research Institute, has developed theoretical models for these parameters. These theoretical models have been applied to predict the occurrence of localized corrosion of base materials and heat-treated components in a variety of environments containing aggressive and non-aggressive species. As a result of this project, a comprehensive model has been established and extensively verified for predicting the occurrence of localized corrosion as a function of environment chemistry and temperature by calculating the corrosion and repassivation potentials.To support and calibrate the model, an experimental database has been developed to elucidate (1) the effects of various inhibiting species as well as aggressive species on localized corrosion of nickel

  14. Corrosion Behavior of Titanium in Artificial Saliva by Lactic Acid

    Directory of Open Access Journals (Sweden)

    Qing Qu

    2014-07-01

    Full Text Available As one of the main products produced by oral microorganisms, the role of lactic acid in the corrosion of titanium is very important. In this study, the corrosion behavior of titanium in artificial saliva with and without lactic acid were investigated by open-circuit potentials (OCPs, polarization curves and electrochemical impedance spectroscopy (EIS. OCP firstly increased with the amount of lactic acid from 0 to 3.2 g/L and then tended to decrease from 3.2 to 5.0 g/L. The corrosion of titanium was distinctly affected by lactic acid, and the corrosion rate increased with increasing the amount of lactic acid. At each concentration of lactic acid, the corrosion rate clearly increased with increasing the immersing time. Results of scanning electron microscopy (SEM also indicated that lactic acid accelerated the pitting corrosion in artificial saliva. A probable mechanism was also proposed to explain the experimental results.

  15. Comparison of corrosion monitoring techniques in district heating systems

    DEFF Research Database (Denmark)

    Hilbert, Lisbeth Rischel; Nielsen, Lars Vendelbo; Thorarinsdottir, R.I.

    2004-01-01

    Investigations aimed at evaluating monitoring techniques as a function of the specific water chemistry has been conducted as a part of a Nordic project focused on improving the quality of corrosion monitoring in municipal district heating. A combination of techniques has been selected to measure...... both general and localised corrosion. Electrochemical techniques (LPR, EIS) as well as direct techniques (high sensitive ER, weight loss, local crevice corrosion current) have been applied. The data show that the water quality in Danish systems is high resulting in low corrosion rates, but changes...... in the water quality induce localised corrosion. Useful monitoring results have been obtained with high sensitive ER technique (MetriCorr) and crevice corrosion measurements with the LOCORR cell (FORCE TECHNOLOGY)....

  16. High temperature corrosion investigation in an oxyfuel combustion test rig

    DEFF Research Database (Denmark)

    Montgomery, Melanie; Bjurman, M.; Hjörnhede, A

    2014-01-01

    Oxyfuel firing and subsequent capture of CO2 is a way to reduce CO2 emissions from coal‐fired boilers. Literature is summarized highlighting results which may contribute to understanding of the corrosion processes in an oxyfuel boiler.Tests were conducted in a 500 kWth oxyfuel test facility...... constructed by Brandenburg Technical University to gain understanding into oxyfuel firing. Two air‐cooled corrosion probes were exposed in this oxyfuel combustion chamber where the fuel was lignite. Gas composition was measured at the location of testing. Various alloys from a 2½ Cr steel, austenitic steels...... (perhaps carburized) zone was used as a measure of corrosion rates. The lowest alloyed steel had the highest corrosion rate, and the other austenitic and nickel alloys had much lower corrosion rates. Precipitates in the alloy adjacent the corrosion front were revealed for both Sanicro 28 and C‐276. However...

  17. Contribution of cellular automata to the understanding of corrosion phenomena

    Directory of Open Access Journals (Sweden)

    M. Zenkri

    2017-09-01

    Full Text Available We present a stochastic CA modelling approach of corrosion based on spatially separated electrochemical half-reactions, diffusion, acido-basic neutralization in solution and passive properties of the oxide layers. Starting from different initial conditions, a single framework allows one to describe generalised corrosion, localised corrosion, reactive and passive surfaces, including occluded corrosion phenomena as well. Spontaneous spatial separation of anodic and cathodic zones is associated with bare metal and passivated metal on the surface. This separation is also related to local acidification of the solution. This spontaneous change is associated with a much faster corrosion rate. Material morphology is closely related to corrosion kinetics, which can be used for technological applications.

  18. Waterside corrosion of zirconium alloys in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Yong Hwan; Baek, B.J.; Park, S.Y. [and others

    1999-08-01

    The overview of corrosion and hydriding behaviors of Zr-based alloy under the conditions of the in-reactor service and in the absence of irradiation is introduced in this report. The metallurgical characteristics of Zr-based alloys and the thermo-mechanical treatments on the microstructures and the textures in the manufacturing process for fuel cladding are also introduced. The factors affecting the corrosion of Zr alloy in reactor are summarized. And the corrosion mechanism and hydrogen up-take are discussed based on the laboratory and in-reactor results. The phenomenological observations of zirconium alloy corrosion in reactors are summarized and the models of in-reactor corrosion are exclusively discussed. Finally, the effects of irradiation on the corrosion process in Zr alloy were investigated mainly based on the literature data. (author). 538 refs., 26 tabs., 105 figs.

  19. Par j 1 and Par j 2, the major allergens from Parietaria judaica pollen, have similar immunoglobulin E epitopes.

    Science.gov (United States)

    Asturias, J A; Gómez-Bayón, N; Eseverri, J L; Martínez, A

    2003-04-01

    Parietaria judaica is the main cause of allergy in Mediterranean countries. The major allergens from P. judaica pollen, Par j 1 and Par j 2, have amino acid sequence identity of 45% and contain eight cysteine residues involved in disulphide bonds that compact the structure. The aim of the study was to identify IgE-binding epitopes on Par j 1 and Par j 2, the major allergens from P. judaica pollen and correlate them with the three-dimensional structure of the proteins. Overlapping peptides representing the complete length of Par j 1 and Par j 2 were synthesized on a cellulose-derivatized membrane. Sera from 17 P. judaica-allergenic patients were used to identify IgE-binding epitopes. Homology modelling of the three dimensional structure of both allergens was generated using the Swiss-Model software on the basis of previously reported crystal structures. Five and eight IgE-binding epitopes were identified on Par j 1 and Par j 2 allergens, respectively. Both proteins belonged to the non-specific lipid transfer proteins (ns-LTP) family and therefore a three-dimensional model of both allergens was constructed on the basis of the maize ns-LTP crystal structure. Par j 1 and Par j 2 allergens have three similar allergenic epitopes with high homology and identical conformation. Three similar IgE-epitopes of major allergens from P. judaica have been described. They could be good candidates for designing of IgE haptens as therapeutic agents with reduced anaphylactic side-effects or for developing hypoallergenic variants of these major allergens.

  20. [Corrosive esophagitis in children (author's transl)].

    Science.gov (United States)

    Arcand, P; Guerguerian, A J

    1982-01-01

    The treatment of corrosive esophagitis in children remains a controversial subject. A review of the literature and the various forms of treatment is presented with a retrospective study done a the Ste-Justine Hospital in Montreal. We studied the charts (327) of patients hospitalized for ingestion of corrosive substances for the period extending between 1970 to 1976 inclusively. The mean age of the patients involved was 2 years 4 months with a slight male predominance (60%). Javel water, sodium hydroxide, Chlorine, ammoniac and different acids were, in this order, the agents most frequently encountered. Esophageal burns proven by endoscopy was noted in 81 cases. Even in the absence of oropharyngeal burns, esophageal involvement was still present in 46% of cases. The low incidence of stenosis (9%) tends to confirm the beneficial role of steroids in the treatment of corrosive esophagitis. This is particularly true for 1st and 2nd degree burns whereas their administration in severe 3rd degree burn remains controversial.