WorldWideScience

Sample records for corrosion inducida por

  1. Osteomalacia inducida por tumor: hemangiopericitoma rinosinusal

    Directory of Open Access Journals (Sweden)

    Enriqueta M. Serafini

    2013-02-01

    Full Text Available La osteomalacia inducida por tumor es una rara enfermedad del metabolismo óseo caracterizada por el aumento en la excreción de fosfato a nivel renal seguido de hipofosfatemia. Es causada por agentes fosfatúricos producidos por determinados tumores. La resección total del tumor resulta en la completa reversión de las anormalidades bioquímicas, la desaparición de las manifestaciones clínicas y los hallazgos en los estudios por imágenes. Presentamos el caso de un varón de 61 años con cuadro clínico y laboratorio compatibles con osteomalacia oncogénica inducida por tumor mesenquimático de localización rinosinusal. En nuestro caso el diagnóstico histológico correspondió a una neoplasia de tipo vascular: hemangiopericitoma.

  2. Hipoglucemia inducida por carcinoma adrenal

    Directory of Open Access Journals (Sweden)

    Jimena Soutelo

    2013-08-01

    Full Text Available El carcinoma suprarrenal es una neoplasia maligna infrecuente y de mal pronóstico. La presentación clínica más común es originada por la producción hormonal excesiva, mientras que el desarrollo de hipoglucemia sintomática es excepcional. Presentamos el caso de una mujer de 37 años que ingresó al hospital por síntomas de hipoglucemias graves, hipertensión arterial, hipopotasemia y amenorrea secundaria. En el laboratorio se halló hipoglucemia con insulina inhibida y niveles de andrógenos en rango tumoral. La tomografía computarizada (TC de abdomen y pelvis mostró voluminosa formación heterogénea de aspecto sólido sin plano de clivaje con respecto al parénquima hepático e intenso realce con contraste. Luego de la extirpación de la masa retroperitoneal, evolucionó con valores de glucemia y potasemia normales, estabilizó la presión arterial y recuperó los ciclos menstruales.

  3. Alteraciones hepáticas inducidas por la nutrición parenteral

    OpenAIRE

    J Salas Salvado; A Recaséns Garica

    1993-01-01

    Liver disorders induced by parenteral nutrition Alteraciones hepáticas inducidas por la nutrición parenteral Liver disorders induced by parenteral nutrition Alteraciones hepáticas inducidas por la nutrición parenteral

  4. Agranulocitosis inducida por metimazol en pacientes con enfermedad de Graves

    Directory of Open Access Journals (Sweden)

    Helard Manrique-Hurtado

    2013-04-01

    Full Text Available Objetivo: Describir las características clínicas y epidemiológicas de los pacientes con enfermedad de Graves que presentaron agranulocitosis inducida por metimazol. Material y métodos: Estudio retrospectivo, tipo serie de casos. Se revisaron las historias clínicas de todos los pacientes con diagnóstico de agranulocitosis inducida por metimazol, atendidos en el Hospital Nacional Arzobispo Loayza, entre enero 2002 y diciembre 2008. Se buscó asociación entre las variables demográficas y clínicas con la mortalidad y el tiempo de recuperación. Resultados: Treinta (0,60% pacientes con enfermedad de Graves fueron hospitalizados con el diagnóstico de agranulocitosis inducida por metimazol. La mediana de la edad fue 33,5 años y 86,67% fueron mujeres. Al ingreso, todos los pacientes presentaron fiebre y dolor de garganta. El manejo incluyó aislamiento invertido, suspensión del metimazol, administración de antibióticos y glucocorticoides. Doce (40% pacientes recibieron GM-CSF. El número de granulocitos se normalizó después de 10,59 días y cuatro (13,33% pacientes murieron por infecciones bacterianas y sepsis. En todos los casos, el tratamiento definitivo fue yodo radioactivo. No hubo diferencia significativa en la edad, sexo, dosis de metimazol, duración del tratamiento y uso de factor estimulante colonia, entre los pacientes fallecidos y los sobrevivientes. Además, el uso de factor estimulante de colonia no redujo el tiempo de recuperación de la agranulocitosis. Conclusión: La agranulocitosis inducida por metimazol es un evento adverso serio y potencialmente mortal. En este grupo de pacientes, la mortalidad fue elevada y el uso de factor estimulante de colonia no disminuyó el tiempo de recuperación.

  5. Vasculitis inducida por metimazol: Reporte de caso

    Directory of Open Access Journals (Sweden)

    Miguel Pinto

    2011-07-01

    Full Text Available Se reporta el caso de una paciente con enfermedad de Graves, que presentó vasculitis asociada al uso de metimazol. Mujer de 14 años, que acudió a consulta por presentar intolerancia al calor, tremor distal y palpitaciones. El examen físico mostró bocio difuso, y el perfil tiroideo, TSH suprimida y hormonas tiroideas elevadas. Los anticuerpos antiperoxidasa tiroidea fueron positivos. Se inició tratamiento con metimazol y beta bloqueadores. Después de 20 días, la paciente regresó por presentar malestar general, fiebre, poliartralgia, lesiones cutáneas maculopapulares y edema de miembros inferiores. Los anticuerpos antinucleares fueron negativos y los anticuerpos anticitoplasma de los neutrófilos (ANCA, positivos. Se suspendió el metimazol y se inició prednisona. Después de 10 días de tratamiento, las molestias desaparecieron y la paciente recibió I 131.Las vasculitis asociadas al uso de tionamidas son poco frecuentes, no dependen de la dosis y están asociadas a la presencia de anticuerpos tipo ANCA. Clásicamente, afectan a los vasos pequeños de la piel; sin embargo, también pueden afectar los riñones y pulmones. El cuadro clínico se caracteriza por artralgias y mialgias. En algunos casos puede ocurrir insuficiencia renal de grado variable. En la mayoría de casos, el cuadro remite con la suspensión de la droga; pero, en algunos se requiere el uso de glucocorticoides o inmunosupresores.(Rev Med Hered 2011;22:147-150.

  6. Osteonecrosis de hueso maxilar inducida por bisfosfonatos

    OpenAIRE

    Vera Sempere, Francisco José

    2016-01-01

    Los bisfosfonatos son un grupo de fármacos, análogos de los pirofosfatos, utilizados en administración oral en el tratamiento de la osteoporosis, así como en formulaciones intravenosas para el tratamiento del dolor óseo y de la hipercalcemia ligada a la enfermedad tumoral metastasica (generalmente en el contexto de mieloma múltiple / cáncer de mama o próstata avanzados), actuando como un inhibidor de la reabsorción ósea, mediada por osteoclastos, así como de la apoptosis de los osteobl...

  7. Osteoporosis secundaria y Osteoporosis inducida por glucocorticoides (OIG

    Directory of Open Access Journals (Sweden)

    Elías Forero Illera

    2006-01-01

    Full Text Available La osteoporosis es un problema de salud pública importante a nivel mundial, y su prevalencia está aumentando. La osteoporosis secundaria se puede producir por varias patologías y el uso de ciertos medicamentos. Los glucocorticoides son un grupo de fármacos usados extensamente en la práctica médica debido a su indiscutible utilidad. La osteoporosis inducida por glucocorticoides es un problema de salud pública. Aunque la patogénesis de la pérdida producida por los glucocorticoides en el hueso no se conoce totalmente, investigaciones recientes han proporcionado nuevas conocimientos en los mecanismos de estos fármacos a nivel celular y molecular. Diversas guías han sido propuestas por diversos grupos para el tratamiento de la OIG; desafortunadamente, las guías del tratamiento no se utilizan adecuadamente en los pacientes.

  8. Estrategias para el tratamiento de la disfunción sexual inducida por la medicación antidepresiva

    Directory of Open Access Journals (Sweden)

    Matthew J. Taylor

    2014-01-01

    Conclusiones de los autores: Las pruebas actualmente disponibles son muy limitadas. En los hombres con disfunción eréctil inducida por antidepresivos, el agregado de sildenafil o tadalafil parece ser una estrategia eficaz. En las mujeres con disfunción sexual inducida por antidepresivos, el agregado de bupropión a dosis mayores parece ser el enfoque más alentador estudiado hasta el presente.

  9. Osteomalacia inducida por tumor: hemangiopericitoma rinosinusal Tumor-induced osteomalacia: rhinosinusal hemangiopericytoma

    Directory of Open Access Journals (Sweden)

    Enriqueta M. Serafini

    2013-02-01

    Full Text Available La osteomalacia inducida por tumor es una rara enfermedad del metabolismo óseo caracterizada por el aumento en la excreción de fosfato a nivel renal seguido de hipofosfatemia. Es causada por agentes fosfatúricos producidos por determinados tumores. La resección total del tumor resulta en la completa reversión de las anormalidades bioquímicas, la desaparición de las manifestaciones clínicas y los hallazgos en los estudios por imágenes. Presentamos el caso de un varón de 61 años con cuadro clínico y laboratorio compatibles con osteomalacia oncogénica inducida por tumor mesenquimático de localización rinosinusal. En nuestro caso el diagnóstico histológico correspondió a una neoplasia de tipo vascular: hemangiopericitoma.Tumor-induced osteomalacia is a rare disease of bone metabolism. The characteristic of this disease is an increase in phosphate excretion followed by hypophosphatemia, due to phosphaturic agents produced by different types of tumors. Tumor resection results in complete resolution of clinical, biochemical and radiological abnormalities. We present the case of a 61 year old man with signs, symptoms and laboratory findings consistent with oncogenic osteomalacia due to a rhino-sinusal mesenchymal tumor. The histological diagnosis showed a vascular neoplasm: hemangiopericytoma.

  10. Insuficiencia renal aguda inducida por mordedura de serpiente Bothrops

    Directory of Open Access Journals (Sweden)

    Gustavo A. Aroca Martínez

    2014-01-01

    Full Text Available Mujer de 58 años de edad, remitida a urgencias por presentar cuadro clínico de insuficiencia renal aguda (IRA secundaria a mordedura de serpiente (Bothrops Atrox. Ingresa hipotensa con elevación de azoados e hiperkalemia, ecografía renal dentro de parámetros normales. Se maneja terapia dialítica con lo cual presenta mejoría clínica. En este reporte se detallan aspectos del diagnóstico, manejo clínico y posibles mecanismos fisiopatológicos que explican el daño renal.

  11. Cardiomiopatía inducida por estrés (Takotsubo en una paciente con anorexia nerviosa

    Directory of Open Access Journals (Sweden)

    Sabrina Vadalá

    2014-06-01

    Full Text Available Presentamos el caso de una mujer con diagnóstico de anorexia nerviosa que desarrolló cardiomiopatía de takotsubo precipitada por estrés emocional y alteraciones del medio interno. Evolucionó favorablemente con manejo conservador. Los casos de cardiomiopatía inducida por estrés, descriptos en pacientes con trastornos de la conducta alimentaria, suelen alcanzar mayor gravedad y se asocian con la prolongación del intervalo QT por desequilibrios electrolíticos, arritmias ventriculares e hipoglucemia. Se realiza una revisión del compromiso cardiovascular en pacientes con anorexia nerviosa.

  12. Capacidad antiteratogénica del resveratrol en diabetes inducida por estreptozotocina en ratas

    Directory of Open Access Journals (Sweden)

    Ninna Leslie Trejo-González

    Full Text Available Objetivos. Evaluar la capacidad antihiperglucémica y antiteratogénica del resveratrol en ratas inducidas a diabetes por estreptozotocina. Materiales y métodos. Estudio de tipo experimental. Se tuvieron tres grupos, de cinco ratas Wistar preñadas cada uno, dos de los cuales fueron tratados el cuarto día de gestación con una dosis de estreptozotocina de 50 mg/kg, disuelta en tampón de citratos, y el otro fue considerado como control, y solo se le administró el tampón de citratos. A uno de los grupos inducidos con estreptozotocina se le administró resveratrol a dosis de 100 mg/kg durante los días 8 al 12 de gestación, cuando sucede la neurulación. Los fetos se obtuvieron el día 19 de gestación y se les realizó un análisis morfológico, y en el hígado fetal se determinó la actividad de las enzimas depuradoras de especies reactivas catalasa, superóxido dismutasa y glutatión peroxidasa. Resultados. La administración de resveratrol (DM+R revierte los parámetros a valores similares a los del grupo control. Las actividades de catalasa y de glutatión peroxidasa, se vieron incrementadas en el grupo tratado con resveratrol con respecto al grupo diabético, en cuanto a la frecuencia de malformaciones en el grupo control y en el grupo tratado con resveratrol no presentaron malformaciones, mientras que en las ratas con diabetes inducida, se encontró una elevada frecuencia de malformaciones. Conclusiones. El resveratrol muestra propiedades antiteratogénicas a través de la disminución del estrés oxidativo que se presenta a causa de la hiperglucemia materna

  13. El aceite de pescado atenua las crisis convulsivas inducidas por hipertermia en ratas neonatas

    Directory of Open Access Journals (Sweden)

    Leopoldo E. Flores M.

    2008-01-01

    Full Text Available Un alto porcentaje (50-60% del cerebro en los mamíferos son principalmente grasas o lípidos, de éstos, el 35% son ácidos grasos esenciales, en particular los llamados omegas (O, como el Acido Docosahexanoico (DHA y el Eicosapentanoico (EPA llamados omega 3 (O-3. Diversos estudios han mostrado beneficios en la salud con la implementación de los O-3 como agentes terapéuticos en alteraciones cardiovasculares, renales, dérmicas, metabólicas, neurodegenerativas e inmunológicas. Evidencias experimentales sugieren un beneficio potencial del aceite de pescado (APE como neuroprotector debido al alto contenido de DHA y EPA. Sin embargo, es poco lo que se conoce en cuanto a los efectos que pudieran tener sobre alteraciones nerviosas, como las crisis convulsivas. En este contexto, se ha reportado que el tipo más común de trastorno epiléptico observado en los niños son las crisis convulsivas provocadas por fiebre (CF. La incidencia es de 3-5%, con ocurrencia entre los 5 meses y 5 años de edad, y se ha propuesto que esta alteración en la vida temprana pudiera tener efectos a largo plazo, manifestándose como un síndrome de epilepsia en la vida adulta. El objetivo del presente estudio fue evaluar el efecto del APE sobre las convulsiones inducidas por hipertermia experimental en un grupo de ratas Wistar macho de 5 días de edad (grupo SAPE cuyas madres consumieron una dieta base más un suplemento de APE (suministrado desde su infancia hasta la etapa de crianza. Este grupo se comparó con otro grupo de ratas de la misma edad y cepa (grupo SAPA cuyas madres consumieron una dieta base más un suplemento de aceite de palma (suministrado desde su infancia hasta la etapa de crianza, y con un tercer grupo de ratas (grupo CTRL cuyas madres consumieron la dieta base más agua bidestilada como suplemento. Las ratas tratadas con APE presentaron mayor resistencia a la elevación de la temperatura corporal inducida por la hipertermia, una menor frecuencia

  14. Disfunción tiroidea inducida por amiodarona en la práctica clínica

    Directory of Open Access Journals (Sweden)

    José Luis Paz-Ibarra

    2011-01-01

    Full Text Available La amiodarona (AMD es una droga antiarrítmica potente (clase III usada en la práctica clínica para la profilaxis y el tratamiento de muchos disturbios del ritmo cardiaco, desde la fibrilación auricular paroxística hasta las taquiarritmias ventriculares que amenazan la vida. Frecuentemente causa cambios en las pruebas de función tiroidea principalmente relacionados a la inhibición de la actividad de la 5'-deiodinasa, resultando en una disminución de la generación de T3 desde T4 y el consecuente incremento en la producción de T3 reversa y una disminución de su aclaramiento. En 14 a 18% de pacientes tratados con AMD hay una disfunción tiroidea manifiesta, ya sea tirotoxicosis inducida por amiodarona (TIA o hipotiroidismo inducido por amiodarona (HIA. Tanto TIA como HIA pueden desarrollarse en glándulas aparentemente normales o en glándulas con anormalidades preexistentes clínicamente silentes. La TIA está primariamente relacionada a la síntesis de hormonas tiroideas inducida por el exceso de yodo en una glándula tiroidea anormal (TIA tipo 1 o a una tiroiditis destructiva relacionada a la amiodarona (TIA tipo 2, aunque frecuentemente ocurren formas mixtas. La tiroiditis de Hashimoto preexistente es un factor de riesgo definido para la ocurrencia de HIA. La patogenia del HIA es la falla para escapar del efecto agudo de Wolff-Chaikoff inducido por el yodo, debido a los defectos en la hormonogénesis tiroidea y, en pacientes con pruebas de autoanticuerpos tiroideos positivos, para tiroiditis de Hashimoto concomitante. La TIA es más común en zonas deficientes de yodo mientras que el HIA es usualmente visto en zonas suficientes en yodo. En contraste al HIA, la TIA es una condición difícil de diagnosticar y tratar, y usualmente se recomienda la descontinuación de la amiodarona. En esta revisión se analiza, de acuerdo a los datos actuales, las alteraciones en las pruebas de función tiroidea vistas en pacientes eutirodeos bajo

  15. Comparative study in the induced corrosion by sulfate reducing microorganisms, in a stainless steel 304L sensitized and a carbon steel API X65; Estudio comparativo de la corrosion inducida por microorganismos sulfatorreductores, en un acero inoxidable 304L sensibilizado y un acero al carbono API X65

    Energy Technology Data Exchange (ETDEWEB)

    Diaz S, A.; Gonzalez F, E.; Arganis J, C.; Luna C, P.; Carapia M, L. [ININ, Carretera Mexico-Toluca Km. 36.5, 52045 Estado de Mexico (Mexico)]. e-mail: ads@nuclear.inin.mx

    2004-07-01

    In spite of the operational experience related with the presence of the phenomenon of microbiological corrosion (MIC) in industrial components, it was not but until the decade of the 80 s when the nuclear industry recognized its influence in some systems of Nuclear Generating Power plants. At the moment, diverse studies that have tried to explain the generation mechanism of this phenomenon exist; however, they are even important queries that to solve, especially those related with the particularities of the affected metallic substrates. Presently work, the electrochemical behavior of samples of stainless steel AISI 304L sensitized is evaluated and the carbon steel APIX65, before the action of sulfate reducing microorganisms low the same experimental conditions; found that for the APIX65 the presence of this type of bacteria promoted the formation of a stable biofilm that allowed the maintenance of the microorganisms that damaged the material in isolated places where stings were generated; while in the AISI 304L, it was not detected damage associated to the inoculated media. The techniques of Resistance to the Polarization and Tafel Extrapolation, allowed the calculation of the speed of uniform corrosion, parameter that doesn't seem to be influenced by the presence of the microorganisms; while that noise electrochemical it distinguished in real time, the effect of the sulfate reducing in the steel APIX65. (Author)

  16. Determination of forces induced by steam flow in turbines; Determinacion de fuerzas inducidas por flujo de vapor en turbinas

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Castrejon, Juan Carlos

    2008-09-15

    blades, has a harmonic pattern. The pressure field variation as time function is uniform: the peaks and valleys across the axial clearance are always in phase. However the instant picture of the pressure field it's different: the peaks and valleys are not in phase and the number of peaks and valley changed across the clearance. In the case of the forces acting on blades, a Fourier on the forces calculated was used to determine the coefficients and frequency of a Fourier equation which can be used to calculate the alternating stresses on the blade in order to predict the useful life blades. [Spanish] Las vibraciones inducidas por flujo de vapor en turbinas representan uno de los problemas que enfrenta la operacion de turbinas de vapor cuya capacidad rebasa los 300 MW. Ademas estas constituyen uno de los limites tecnologicos para el desarrollo de turbinas de vapor de mas de 1 GW. Este tipo de fenomeno tiene su origen en la interaccion del rotor con el fluido que se encuentra en sus proximidades. El flujo de vapor dentro de la turbina es complejo, ya que es turbulento e inestable. A medida que el flujo pasa una etapa de estator o de rotor, se generan secundarios, vortices en los filos de salida, estelas con caracteristicas de flujo diferentes al flujo principal en los pasajes. Estas variaciones en el flujo son las que inducen vibraciones forzadas en los alabes. Ademas existen varios factores que contribuyen a la aplicacion de vibraciones en alabes inducidas por flujo como son: inestabilidad del flujo de vapor en los claros de los sellos, secuencia de apertura de las valvulas, estelas de las toberas, obstrucciones en algunas de las toberas y diferente espaciamiento en las toberas. Las vibraciones por flujo pueden ser peligrosas si su frecuencia coincide con la frecuencia natural del sistema, provocando efectos mas nocivos que las vibraciones por desbalance o por desalineamiento, pues tienen amplitudes mas grandes y provocan esfuerzos alternantes en los componentes del

  17. Arteriopatía periférica crónica inducida por cocaína

    Directory of Open Access Journals (Sweden)

    Sonia Pankl

    2012-02-01

    Full Text Available La trombosis periférica aguda inducida por cocaína ha sido descripta en la literatura, siendo una complicación poco común. Si bien existen comunicaciones que reflejan los efectos crónicos de la cocaína sobre el sistema arterial periférico, no hay casos publicados de tal complicación en ausencia de otros factores de riesgo. Se presenta el caso de una mujer de 22 años de edad con antecedentes de consumo de cocaína intranasal de 3 gramos por semana durante un año, que consultó por claudicación intermitente a los 200 metros asociada a dolor y parestesias en miembro inferior izquierdo de 2 meses de evolución. El ecodoppler arterial evidenció una estenosis mayor del 70% en la arteria femoral superficial izquierda. Se realizaron estudios complementarios descartando otras etiologías probables. Se inició tratamiento con ácido acetilsalicílico, cilostazol y ejercicio reglado, asociado a terapia de apoyo para mantenimiento del cese del consumo de cocaína, con buena respuesta. Se destaca la importancia de la difusión de información a los pacientes, dado que la mayoría de la población desconoce las complicaciones cardiovasculares de dicha adicción. Es indispensable indagar sobre el consumo de cocaína en pacientes jóvenes con arteriopatía sin factores de riesgo aparentes.

  18. Paciente con trombocitopenia trombótica inducida por heparina en hemodiálisis: abordaje de la anticoagulación del circuito

    Directory of Open Access Journals (Sweden)

    Mirian García Martínez

    Full Text Available Resumen El tratamiento renal sustitutivo de hemodiálisis es una técnica de depuración sanguínea extraterrenal, que requiere proteger al circuito extracorpóreo del paciente. Actualmente la heparina es el anticoagulante endovenoso de elección para evitar este tipo de complicaciones intradiálisis, siendo necesaria la individualización de las dosis por paciente. La trombocitopenia trombótica inducida por heparina es uno de los posibles efectos secundarios producidos por la administración de heparina. La bivalirudina es un inhibidor directo y específico de la trombina, útil en diferentes procedimientos, siendo utilizado en pacientes con problemas con la heparina y con fracaso renal crónico terminal que requieren terapias de diálisis continuas. Caso clínico: Paciente de 46 años, con múltiples antecedentes personales. Al inicio de su proceso debutó con una Gangrena de Fournier secundaria a isquemia de extremidades inferiores, por lo que precisó tratamiento anticoagulante. Hasta la fecha no presentó alergias medicamentosas conocidas. Posteriormente se objetivó plaquetopenia progresiva con diagnóstico de trombocitopenia inducida por heparina tipo II por lo que se restringió la heparina de bajo peso molecular y la heparina sódica, indicándose anticoagulación con Sintrom y Bivalirudina en casos de procedimientos con alto riesgo de sangrado. Conclusiones: Los pacientes de hemodiálisis en nuestro hospital, tienen como pauta habitual de anticoagulación la heparina. En este caso el diagnostico precoz de la trombocitopenia trombótica inducida por la heparina, fue crucial para evitar daños mayores, siendo el equipo de enfermería la piedra angular en el tratamiento en la sala de hemodiálisis.

  19. El tratamiento con progesterona previene las alteraciones motoras inducidas por la intoxicación con semillas de cícada (Dioon spinulosum) en la rata macho

    OpenAIRE

    E Rivadeneyra-Domínguez; M Saavedra; JF Rodríguez-Landa

    2009-01-01

    El consumo crónico de semillas de cícadas ha sido asociado con enfermedades neurodegenerativas, las cuales predominan en el género masculino. En México, las semillas de cícada (Dioon spinulosum) son usadas como sustituto de maíz y a nivel experimental producen un déficit motor; probablemente causado por sus componentes neurotóxicos. En este sentido, la progesterona ejerce efectos neuroprotectores contra traumatismo cerebral, hipoxia, así como la muerte neuronal inducida por colchicina en el S...

  20. Papel del endotelio en hipertensión inducida por el embarazo: ¿alteraciones comunes a las de la aterosclerosis?

    OpenAIRE

    López-Jaramillo, Patricio; Sotomayor-Rubio, Katherine; Sotomayor-Rubio, Arístides; López-López, Cristina

    2014-01-01

    La hipertensión inducida por el embarazo, cuya forma proteinúrica es denominada preeclampsia (PE), es una alteración que ocurre en el segundo trimestre del embarazo, y se caracteriza por la presencia de hipertensión y proteinuria. Durante el embarazo normal ocurren cambios fisiológicos adaptativos que incluyen insulino-resistencia (IR), hiperlipidemia, hipercoagulabilidad, inflamación y un estado circulatorio hiperdinámico. Estos cambios se expresan de una forma exagerada en las mujeres que d...

  1. Detección y estudio mediante Fluorescencia Inducida por Láser de radicales libres formados por Disociación Multifotónica Infrarroja

    Science.gov (United States)

    Santos, M.; Díaz, L.; Torresano, J. A.; Rubio, L.; Samoudi, B.

    Una de las principales aplicaciones actuales de los procesos de disociación multifotónica inducidos por radiación láser infrarroja (DMI) es la producción de radiales libres, con el fin de estudiar sus propiedades cinéticas y espectroscópicas. La disociación de moléculas poliatómicas en el IR con láseres de CO2 tiene lugar desde la superficie de energía molecular mas baja y conduce generalmente a la formación de fragmentos en el estado electrónico fundamental, con diversos grados de excitación vibracional. En el Grupo de Procesos Multifotónicos del Instituto de Estructura de la Materia del C.S.I.C. hemos puesto a punto la técnica de Fluorescencia Inducida por Láser (LIF) para la detección y análisis en tiempo real de los fragmentos producidos en la DMI inducida mediante uno o dos campos láseres de diferentes longitudes de onda. Objetivos de nuestro trabajo han sido el estudio de los canales de disociación mayoritarios y de las especies transitoria producidas, así como de la distribución de energía interna con que éstas son generadas. En particular hemos detectado mediante LIF las especies: C2, CF, CH, SiH2, CF2, CH2, SiHCl, y CF3 a partir de la disociación de, entre otras, las siguientes moléculas: C2H3Br, C3F6, C4H8Si, C2H5ClSi y CH5ClSi. En este trabajo presentamos algunos de los resultados obtenidos mediante el estudio por LIF de estos radicales: estudio temporal de la señal LIF obtenida con determinación de tiempos de vida, espectros de excitación y fluorescencia, temperaturas vibracionales de formación, variación de la intensidad LIF con el tiempo de retraso entre los láseres de disociación y prueba, etc.

  2. Efecto de Gentianella alborosea en esteatosis hepática no alcohólica inducida por dieta hiperlipídica en ratas holtzman hembras

    OpenAIRE

    L Ugaz-Soto; JH Zafra-Tanaka; María E. Tapia Vicente

    2013-01-01

    Objetivo: Determinar el efecto del extracto de Gentianella alborosea como tratamiento contra esteatosis hepática no alcohólica (EHNA)  inducida por dieta hiperlipídica en ratas Holtzman hembras. Métodos: Diseño: Estudio experimental incompleto. Lugar: Universidad Nacional Mayor de San Marcos, Lima, Perú. Participantes: Ratas Holtzman hembras. Intervenciones: Se utilizó 32 ratas repartidas en 4 grupos (n=8) distribuidos aleatoriamente: grupo control negativo, control positivo con dieta hiperli...

  3. Papel antioxidante de la vitamina E en la aterogénesis inducida por hiperfibrinogenemia

    Directory of Open Access Journals (Sweden)

    Mónica Moya

    2010-01-01

    Full Text Available Con el propósito de estudiar el efecto de la vitamina E sobre el estrés oxidativo desencade- nado por hiperfibrinogenemia (HF en un modelo experimental de aterogénesis y la posible normalización de los indicadores de estrés oxidativo, se evaluaron: óxido nítrico (NO, L-citrulina, superóxido dismutasa (SOD e involución de lesiones histopatológicas en la aorta torácica. El estudio se realizó en 36 ratas, cepa Wistar, que se dividieron en tres grupos (n = 12 cada uno: A, control; B, HF × 90 días; C, HF × 90 días + vitamina E. La HF se indujo mediante inyecciones de adrenalina (0,1 ml/día/rata por 90 días. La dosis de vitamina E fue de 2 mg/día/rata durante 75 días. Se dosaron en plasma los niveles de fibrinógeno (mg/dl, NO (uM y L-citrulina (mM y en lisado de glóbulos rojos, por espectrofotometría, se determinó la actividad de la SOD (U/ml. Se analizaron cortes de la aorta torácica por microscopia óptica (MO. Para el análisis estadístico se emplearon MANOVA y la prueba de Fisher; se estableció un nivel de significación de p < 0,05. Se observó un aumento significativo de fibrinógeno en el grupo B (407 ± 8,9 mg/dl en comparación con los grupos A (203 ± 9 mg/dl y C (191,58 ± 17,79 mg/dl (p < 0,001. El NO disminuyó significativamente en el grupo B (13,73 ± 1,76 uM frente a los grupos A (23,58 ± 0,08 uM y C (26,64 ± 3,65 uM (p < 0,001. La L-citrulina aumentó en forma significativa en los grupos B (4,99 ± 0,18 mM y C (6,60 ± 0,16 mM en comparación con el grupo A (3,03 ± 0,13 mM (p < 0,001. El SOD incrementó su actividad en los grupos B (251,67 ± 10,34 U/ml y C (304,75 ± 10,43 U/ml frente al grupo A (139,44 ± 4,74 U/ml (p < 0,001. La microscopia óptica mostró denudación endotelial, engrosamiento intimal y protrusión de la pared en el grupo B (90% y recuperación de la denudación endotelial y disminución del 50% del engrosamiento intimal en el grupo C (p < 0,001. Niveles aumentados de SOD ser

  4. EFECTO IN VITRO DE LA INSULINA SOBRE LA CAPACIDAD CONTRACTIL UTERINA INDUCIDA POR OXITOCINA

    OpenAIRE

    Figueroa D.,Horacio; Marusic B.,Elisa T.; González N.,Magdalena; Barcos M.,Francisca; Yungue V.,Paola

    2002-01-01

    La capacidad contráctil del útero puede ser evaluada in vitro por medio del método isométrico. El objetivo de este estudio fue comparar la efectividad de la administración simultánea de oxitocina e insulina en la contractilidad uterina. La comparación entre ambas hormonas se realizó en úteros aislados de dos modelos experimentales: ratas hembras adultas en diferentes fases del ciclo estral y ratas preñadas en fase final de preñez. Los úteros de estos animales fueron sometidos, in vitro, a la ...

  5. Mecanismos de Defensa del Hospedero en Estomatitis Sub-Protesica Inducida por Candida

    OpenAIRE

    Cardozo de Pardi, Elba Inés

    2002-01-01

    La Estomatitis Sub-Protésica (E.S.P.) es una entidad que se localiza principalmente en la mucosa del paladar que se encuentra por debajo de la superficie de ajuste de las prótesis removibles parciales y totales. Esta patología es más común en mujeres que en hombres y se observa más frecuentemente en sujetos con edades comprendidas entre 25 y 90 años. Diversos estudios han revelado que la E.S.P. está asociada con la detección de especies de Candida y de otros microorganismos, mientras que otro...

  6. Epitelización inducida por células troncales derivadas del tejido adiposo

    OpenAIRE

    M. Meruane; S. Benítez; M. Rojas; A. Sagredo; K. Marcelain; B. Villalobos

    2014-01-01

    El tratamiento de lesiones con pérdida de tejido cutáneo ha mejorado notablemente con el advenimiento de la bioingeniería tisular. Una alternativa en desarrollo es la utilización de sustitutos dérmicos combinados con células troncales derivadas del tejido adiposo autólogo. Estudios previos nos muestran que con esta técnica es posible optimizar la angiogénesis y la síntesis de colágeno, sin embargo potenciar la epitelización es un tema pendiente por resolver. En el presente estudio evaluamos l...

  7. Degeneracion axónica inducida por tratamiento local con diisopropilfluorofosfato

    OpenAIRE

    Mauricio, María Cruz; Carrera, Victoria; Vilanova Gisbert, Eugenio; Juan Herrero, Joaquín de

    1989-01-01

    Existen especies animales, incluida la humana y las aves, susceptibles de manifestar una polineuropatía retardada tras una intoxicación accidental o la dosificación sistémica experimental con algunos compuestos organfosforados. En este estudio se planteó observar la existencia o no de lesiones nerviosas producidas tras la administración de diisopropilfluorofosfato por via local, siguiendo un modelo de dosificación "in situ". Aquí se describen las observaciones clínicas y lesiones morfológicas...

  8. Muerte súbita debida a cardiotoxicidad aguda inducida por antraciclinas

    Directory of Open Access Journals (Sweden)

    Orlando D. Navarro-Ulloa

    2018-01-01

    Full Text Available Antraciclinas como la doxorrubicina, así como anticuerpos monoclonales, como el trastuzumab, y agentes alquilantes, como la ciclofosfamida, son compuestos muy útiles como quimioterapia citotóxica al reducir en forma significativa la mortalidad relacionada con el cáncer. Sin embargo, su potencial cardiotoxicidad es un efecto adverso mayor que puede presentarse en cualquier momento de su administración o posterior a la misma, en especial cuando se usan combinados. La toxicidad cardiovascular por doxorrubicina suele ser dependiente de dosis e irreversible, mientras la ocasionada por trastuzumab no lo es. Se han encontrado cambios electrocardiográficos habituales durante la administración de quimioterapia, independiente de la dosis acumulada; a estos cambios agudos se les ha dado poca importancia, aunque pueden suceder hasta en el 40% de los pacientes. A pesar de la aparición documentada de arritmias tanto en humanos como en modelos animales, la muerte súbita cardiaca durante o inmediatamente después de la infusión de quimioterapia no está bien descrita. Se presenta el caso de un adulto joven sin antecedentes cardiovasculares, con linfoma no-Hodgkin y corazón con imagen ecocardiográfica muy sugestiva de infiltración linfomatosa del ventrículo izquierdo, quien desarrolla alteraciones del ritmo cardiaco que condicionan muerte súbita tras la infusión endovenosa lenta de doxorrubicina y trastuzumab.

  9. Epitelización inducida por células troncales derivadas del tejido adiposo

    Directory of Open Access Journals (Sweden)

    M. Meruane

    2014-06-01

    Full Text Available El tratamiento de lesiones con pérdida de tejido cutáneo ha mejorado notablemente con el advenimiento de la bioingeniería tisular. Una alternativa en desarrollo es la utilización de sustitutos dérmicos combinados con células troncales derivadas del tejido adiposo autólogo. Estudios previos nos muestran que con esta técnica es posible optimizar la angiogénesis y la síntesis de colágeno, sin embargo potenciar la epitelización es un tema pendiente por resolver. En el presente estudio evaluamos la progresión y diferenciación epitelial en un período de tiempo prologando. Obtuvimos las células troncales a partir del tejido adiposo (ASC de la región inguinal de 4 ratas Sprague Dawley. Cultivamos las células frescas en una matriz de Integra® durante un período total de 48 horas, y las marcamos con un vector lentiviral-GFP (proteína fluorescente verde. Posteriormente, injertamos en las mismas ratas la matriz dérmica con células troncales y un implante contralateral sin células, como control. A las 4 semanas, evaluamos el avance epitelial mediante planimetría de superficie e histología. Los resultados macroscópicos muestran que el cierre de la herida por contracción de los bordes no tiene diferencias significativas (82,63% ± 3,4% vs. 80,66% ± 3,89%; p=0,08, pero el cierre por epitelización fue significativamente mayor en el lado intervenido con ASCs (93,47% ± 5,98% vs. 79,88% ± 6,28%; p=0,0028. Todas las muestras obtuvieron tinción positiva para el anticuerpo anti-citoqueratina 34βE12 y el avance epitelial lineal cuantificado por microscopía resultó significativamente mayor en el lado con ASCs (6408 ± 275μm vs. 5375 ± 250μm; p < 0,001. Identificamos las células GFP positivas formando parte de la dermis regenerada, no así en la epidermis. En conclusión, las células troncales derivadas del tejido adiposo autólogo sembradas en una matriz de Integra® aumentan la formación epitelial significativamente

  10. EFECTO DEL DIMETILSULFÓXIDO EN UN MODELO ANIMAL DE NEFROTOXICIDAD INDUCIDA POR GENTAMICINA EN CONEJOS

    Directory of Open Access Journals (Sweden)

    Oscar Francisco López Núñez

    2013-01-01

    Full Text Available Objetivo: La utilidad clínica de la gentamicina se ve limitada por sus efectos deletéreos renales, causados principalmente por daño oxidativo. Dado que el dimetilsulfóxido posee propiedades antioxidantes, se plantea su uso como agente nefroprotector en un modelo animal. Métodos: Se distribuyeron de forma aleatoria 24 conejos en 3 grupos (A, B y C, se administró durante 5 días solución salina normal 0,9%(SSN para el grupo A, gentamicina más SSN par el grupo B y gentamicina más dimetilsulfóxido al 25% para el grupo C. Se determinaron los parámetros: creatinina sérica, actividad enzimática (n-acetyl-b-d-glucosaminidasa urinaria e histopatología renal. Resultados: La creatinina aumentó respecto al valor basal en los grupos B y C (p=0,009. La comparación del incremento entre grupo A vs C mostró significancia estadística (p=0,0194. La clasifica- ción para lesión renal aguda RIFLE fue del 25% y 50% en estadío Riesgo para los grupos C y B respectivamente y 12,5% en estadío Injuria para el grupo B. La actividad de n-acetyl-b-d-glucosaminidasa urinaria presentó incrementos en todas sus mediciones (p<0,05. La histopatología reveló necrosis mayor del 50% de los túbulos proximales en el 25% del grupo C y 87,5% del grupo B, así como necrosis total en 12,5% del grupo B. Se observaron diferencias entre el grupo A vs B (p<0,001 y C (p<0,05. Conclusiones: El modelo planteado induce nefrotoxicidad. El uso de dimetilsulfóxido no redujo el incremento en los niveles de creatinina y en actividad enzimática, mientras que la Lesión Renal Aguda (LRA por evaluación histopatológica presentó una leve mejoría que carece de respaldo estadístico.

  11. EFECTO DEL DIMETILSULFÓXIDO EN UN MODELO ANIMAL DE NEFROTOXICIDAD INDUCIDA POR GENTAMICINA EN CONEJOS

    Directory of Open Access Journals (Sweden)

    Oscar Francisco López Núñez

    2013-07-01

    Full Text Available Objetivo: La utilidad clínica de la gentamicina se ve limitada por sus efectos deletéreos renales, causados principalmente por daño oxidativo. Dado que el dimetilsulfóxido posee propiedades antioxidantes, se plantea su uso como agente nefroprotector en un modelo animal. Métodos: Se distribuyeron de forma aleatoria 24 conejos en 3 grupos (A, B y C, se administró durante 5 días solución salina normal 0,9%(SSN para el grupo A, gentamicina más SSN para el grupo B y gentamicina más dimetilsulfóxido al 25% para el grupo C. Se determinaron los parámetros: creatinina sérica, actividad enzimática (n-acetyl-b-d-glucosaminidasa urinaria e histopatología renal. Resultados: La creatinina aumentó respecto al valor basal en los grupos B y C (p=0,009. La comparación del incremento entre grupo A vs C mostró significancia estadística (p=0,0194. La clasificación para lesión renal aguda RIFLE fue del 25% y 50% en estadío Riesgo para los grupos C y B respectivamente y 12,5% en estadío Injuria para el grupo B. La actividad de n-acetyl-b-d-glucosaminidasa urinaria presentó incrementos en todas sus mediciones (p<0,05. La histopatología reveló necrosis mayor del 50% de los túbulos proximales en el 25% del grupo C y 87,5% del grupo B, así como necrosis total en 12,5% del grupo B. Se observaron diferencias entre el grupo A vs B (p<0,001 y C (p<0,05. Conclusiones: El modelo planteado induce nefrotoxicidad. El uso de dimetilsulfóxido no redujo el incremento en los niveles de creatinina y en actividad enzimática, mientras que la Lesión Renal Aguda (LRA por evaluación histopatológica presentó una leve mejoría que carece de respaldo estadístico. Palabras Clave: Dimetilsulfóxido, gentamicina, lesión renal aguda, radicales libres

  12. Efecto Protector de Peumus Boldus en ratas con toxicidad hepática inducida por Paracetamol

    Directory of Open Access Journals (Sweden)

    Christiam Ochoa

    2008-01-01

    Full Text Available Objetivo: Comprobar el efecto protector hepático del extracto acuoso de boldo (EAB (Peumus boldus al daño hepático inducido por acetaminofén (paracetamol. Diseño: Analítico, experimental, aleatorizado, completo ¿ experimento verdadero. Realizado en el Instituto de Patología de la Facultad de Medicina de UNMSM. Material y método. 30 Ratas Holtzman macho de 250g y dos meses se dividieron en 5 grupos aleatoriamente, grupo blanco, control paracetamol 200mg/kg y 3 experimentales tratados con EAB a 80 mg/kg, 120 mg/kg y 160 mg/kg respectivamente. Se administró EAB de 80 mg/kg, 120 mg/kg y 160 mg/kg vía orogástrica. Luego de media hora se administró paracetamol 200mg/kg i.p. a los grupos control y experimentales. Este procedimiento se repitió por 5 días. Se tomó pruebas de transaminasas (TGP basal y final en sangre. Se utilizó la prueba de Kruskal-Wallis para analizar la data y un p<0.05 fue considerado significante. Se estudió la anatomopatología de los hígados y se tomaron muestras de tejido teñidas con HE. Resultados: Existe diferencia significativa en los niveles de transaminasas (TGP entre grupos (p<0.05. El control obtuvo 196.6 U/L +- 38.1 (TGP mientras que los experimentales como máximo 55.6 U/l. Las muestras control evidencian signos de lesión hepática, degeneración grasa, congestión sinusoidal y centrolobulillar, y necrosis celular. Sin embargo los grupos experimentales no presentan signos de lesión celular y hay ausencia de inflamación. Conclusiones: El boldo tiene un efecto protector hepático al daño inducido por paracetamol en ratas Holtzmann.

  13. EFECTO PROTECTOR DE PEUMUS BOLDUS EN RATAS CON TOXICIDAD HEPÁTICA INDUCIDA POR PARACETAMOL

    Directory of Open Access Journals (Sweden)

    Christiam Ochoa

    2012-02-01

    Full Text Available Objetivo: Comprobar el efecto protector hepático del extracto acuoso de boldo (EAB (Peumus boldus al daño hepático inducido por acetaminofén (paracetamol. Diseño: Analítico, experimental, aleatorizado, completo – experimento verdadero. Realizado en el Instituto de Patología de la Facultad de Medicina de UNMSM. Material y método. 30 Ratas Holtzman macho de 250g y dos meses se dividieron en 5 grupos aleatoriamente, grupo blanco, control paracetamol 200mg/kg y 3 experimentales tratados con EAB a 80 mg/kg, 120 mg/kg y 160 mg/kg respectivamente. Se administró EAB de 80 mg/kg, 120 mg/kg y 160 mg/kg vía orogástrica. Luego de media hora se administró paracetamol 200mg/kg i.p. a los grupos control y experimentales. Este procedimiento se repitió por 5 días. Se tomó pruebas de transaminasas (TGP basal y final en sangre. Se utilizó la prueba de Kruskal-Wallis para analizar la data y un p<0.05 fue considerado significante. Se estudió la anatomopatología de los hígados y se tomaron muestras de tejido teñidas con HE. Resultados: Existe diferencia significativa en los niveles de transaminasas (TGP entre grupos (p<0.05. El control obtuvo 196.6 U/L +- 38.1 (TGP mientras que los experimentales como máximo 55.6 U/l. Las muestras control evidencian signos de lesión hepática, degeneración grasa, congestión sinusoidal y centrolobulillar, y necrosis celular. Sin embargo los grupos experimentales no presentan signos de lesión celular y hay ausencia de inflamación. Conclusiones: El boldo tiene un efecto protector hepático al daño inducido por paracetamol en ratas Holtzmann.

  14. La fragmentación territorial inducida por el centralismo fiscal, Colombia (1984-2013

    Directory of Open Access Journals (Sweden)

    Oscar Alfredo Alfonso Roa

    2015-07-01

    Full Text Available Los debates a la organización del Estado en América Latina son inagotables, porque la universalización de los bienes públicos y la consecuente elevación del nivel de vida de los ciudadanos es un desafío inalcanzado. Los excesos de centralismo en Colombia limitan la eficacia del modelo territorial de Estado mientras que el avance de la corrupción es innegable y, por tanto, la necesidad de nuevas reglas de distribución del poder es inaplazable. Uno de los efectos más duraderos de ese tipo de intervención es la fragmentación territorial en heterogéneos regímenes espaciales que van más allá de la mera regionalización con criterios naturalistas o de contigüidad geográfica.

  15. Protección inducida por nanococleatos derivados de proteoliposomas de Leptospira interrogans serovar Canicola

    Directory of Open Access Journals (Sweden)

    Beatriz Tamargo

    2012-04-01

    Full Text Available Desde los años 20 del pasado siglo, hasta el presente, en el mundo se han desarrollado y empleado vacunas de células enteras contra la leptospirosis que confieren una corta inmunidad; la mayoría no adyuvadas y dirigidas, fundamentalmente, contra los diferentes serogrupos de la especie Leptospira interrogans, contenidos en las preparaciones. Numerosos han sido los intentos realizados para lograr una formulación vacunal más pura, efectiva, de amplio espectro y duración de la protección que las bacterinas de células enteras inactivadas. Sin embargo, hasta el momento no se ha registrado ninguna vacuna con tales características. En el presente trabajo se obtuvieron antígenos de membrana externa a partir de una cepa cubana autóctona (Cepa 87, L. interrogans serovar Canicola, mediante una modificación de la tecnología para la producción de vesículas de membrana, patentada por investigadores del Instituto Finlay. Estos antígenos con estructura nanoproteoliposómica fueron formulados/adyuvados mediante diferentes estrategias, logrando cinco preparaciones con estructura coclear, que constituyen nanopartículas de aproximadamente 100 a 150 nm de largo y entre 15 a 30 nm de diámetro. Los inmunógenos se inocularon en el biomodelo Mesocrisetus aureatus, con dos dosis e intervalo de seis semanas. El reto fue realizado con 100.000 DL 50 . Los resultados demuestran que las nuevas formulaciones vacunales confieren protección frente al reto homólogo y fueron capaces de eliminar el estado de portador, lo que unido a la robustez del método de preparación, el mayor nivel de pureza, en comparación con las bacterinas, y la no necesidad del hidróxido de aluminio, las convierten en una alternativa de interés para continuar su desarrollo.

  16. Costo-efectividad de medios de contraste isoosmolales e hiposmolales en pacientes con alto riesgo de nefropatía inducida por medio de contraste

    Directory of Open Access Journals (Sweden)

    Liliana Alejandra Chicaíza-Becerra

    2012-06-01

    Full Text Available Introducción. Los medios de contraste pueden provocar falla renal aguda por toxicidad directa sobre las células tubulares e isquemia medular renal. Los pacientes diabéticos y los hospitalizados presentan mayor riesgo de desarrollar nefropatía inducida por medios de contraste que la población general. Objetivo. Establecer el costo-efectividad de los medios de contraste isosmolales e hiposmolales en pacientes con alto riesgo. Materiales and métodos. El análisis se basó en una revisión sistemática de la literatura científica, comparando los efectos nefrotóxicos de los medios isosmolales e hipoosmolales. Se consideraron sólo los costos directos, obtenidos del manual tarifario. Se calcularon las tasas del incremento del costoefectividad, las curvas de eficiencia y de aceptabilidad. Se hicieron análisis univariados de sensibilidad para costos y efectos, así como probabilísticos. Se aplicaron tasas de descuento de 0 y 3 % a losresultados. Se usó como umbral de costo-efectividad por año de vida ganado, el producto interno bruto per cápita. Resultados. Las alternativas con Iopamidol y Iodixanol dominan a las demás porque reducen el riesgo de nefropatía inducida por contraste a un menor costo. La razón del incremento del costo-efectividad del iodixanol comparado con el iopamidol es de US$ 14.660 por año de vida ganado que más que duplica el umbral. Conclusión. El medio de baja osmolalidad, iopamidol, parece ser costo-efectivo comparado con iohexol u otros medios hiposmolares (iopromide, iobitridol, iomeprol, iopentol y ioxilan, en pacientes con alto riesgo de nefropatía inducida por contraste. La elección del medio hiposmolar, depende de la disponibilidad a pagar o del costo por ampolleta.   doi: http://dx.doi.org/10.7705/biomedica.v32i2.367

  17. Efecto antihipertensivo del extracto de Piper aduncum ‘matico’ sobre la hipertensión inducida por L-NAME en ratones

    Directory of Open Access Journals (Sweden)

    Jorge Arroyo

    2012-10-01

    Full Text Available Introducción: El Piper aduncum es una planta conocida como matico. Se le atribuye efectos antihipertensivo, antiinflamatorio, cicatrizante. Objetivos: Determinar el efecto antihipertensivo del extracto de Piper aduncum ‘matico’, sobre la hipertensión inducida por L-NAME, en ratones. Diseño: Experimental. Lugar: Facultades de Medicina y de Farmacia y Bioquímica, Universidad Nacional Mayor de San Marcos, Lima, Perú. Material biológico: Extracto etanólico de las hojas de Piper aduncum y ratas. Intervenciones: Se utilizó seis grupos de seis ratones Muss musculus cada uno, uno sin hipertensión (control negativo y cuatro con hipertensión inducida por L-NAME: un control positivo y tres grupos para las dosis de 50, 150 y 300 mg/kg, respectivamente. El tratamiento se realizó por vía oral, una vez por día, durante 25 días. Las mediciones de la presión arterial sistólica (PAS, presión arterial diastólica (PAD y presión arterial media (PAM fueron realizadas dos veces por semana (martes y viernes y se consideró las mediciones entre los días 19 y 23 de iniciado el tratamiento. Principales medidas de resultados: Actividad antihipertensiva. Resultados: En los días 19 y 23 se observó los mejores niveles de presión arterial en el grupo control y los experimentales, correspondiendo a las mediciones 6 y 7. La eficacia antihipertensiva para enalapril fue 24,1 a 20,6%, respectivamente, seguida por matico, entre 24,9 y 13,7% (p<0,05. Conclusiones: En las condiciones experimentales, se demostró la actividad antihipertensiva del extracto etanólico de hojas de Piper aduncum ‘matico’.

  18. Efecto hipoglucemiante del extracto etanólico de Geranium ruizii Hieron. (pasuchaca en la hiperglucemia inducida por aloxano en ratas

    Directory of Open Access Journals (Sweden)

    Oscar Herrera-Calderon

    2015-04-01

    Full Text Available Introducción: Geranium ruizii (Pasuchaca es una planta medicinal utilizada tradicionalmente como hipoglucemiante en el departamento de Ancash, Perú. Objetivo: Evaluar el efecto hipoglucemiante del extracto etanólico de Geranium ruizii administrada en ratas con hiperglicemia inducida por aloxano. Diseño: Experimental. Institución: Laboratorio de Farmacología Experimental, Facultad de Medicina Humana, Universidad Nacional Mayor de San Marcos, Lima, Perú. Material biológico: Planta entera de Geranium ruizii, ratas Holtzman hembras de ocho semanas con 200 ± 20 g de peso corporal. Intervenciones: La hiperglicemia fue inducida con aloxano. Las ratas incluidas en el estudio presentaron una glicemia > 200 mg/dL. Se formaron seis grupos de seis ratas cada uno. El grupo I recibió agua destilada 2 mL; los grupo II, III y IV recibieron Geranium ruizii 50 mg/kg; 150 mg/kg y 300 mg/kg, respectivamente (vía oral; al grupo V se administró glibenclamida 5 mg/kg y al grupo VI insulina 4UI/kg. Principales medidas de los resultados: Glucemia (mg/ dL, porcentaje de inhibición del radical DPPH, especies reactivas al ácido tiobarbitúrico (TBARS (nmoles/mL, estudio histológico de páncreas. Resultados: La dosis de 150 mg/kg de G. ruizii redujo 65,58% los valores de glicemia a las 2 h post administración (Kruskal Wallis; p< 0,001, redujo TBARS en 22,34% e inhibió el radical DPPH en 23,66%; el tejido pancreático se mantuvo en buen estado de conservación. Conclusiones: El extracto etanólico de Geranium ruizii (pasuchaca tuvo efecto hipoglicemiante en ratas con hiperglucemia inducida con aloxano.

  19. Hiperalgesia Inducida por Opioides

    OpenAIRE

    Jiménez Salazar, Andrés

    2013-01-01

    Los opioides producen analgesia a través de un efecto inhibitorio sobre el sistema nociceptivo principalmente. Hasta la fecha, los opioides siguen siendo los analgésicos más potentes para el manejo de dolor moderado a severo. La Asociación Internacional del Estudio del Dolor (IASP, en inglés) define hiperalgesia como "un aumento de la respuesta a un estímulo que normalmente es doloroso". En contraste, está bien establecido que la terapia crónica con opioides se asocia con el desarrollo de ...

  20. Efecto de Gentianella alborosea en esteatosis hepática no alcohólica inducida por dieta hiperlipídica en ratas holtzman hembras

    Directory of Open Access Journals (Sweden)

    L Ugaz-Soto

    2013-01-01

    Full Text Available Objetivo: Determinar el efecto del extracto de Gentianella alborosea como tratamiento contra esteatosis hepática no alcohólica (EHNA  inducida por dieta hiperlipídica en ratas Holtzman hembras. Métodos: Diseño: Estudio experimental incompleto. Lugar: Universidad Nacional Mayor de San Marcos, Lima, Perú. Participantes: Ratas Holtzman hembras. Intervenciones: Se utilizó 32 ratas repartidas en 4 grupos (n=8 distribuidos aleatoriamente: grupo control negativo, control positivo con dieta hiperlipídica, dosis 1 (35 mg/kg y dosis 2 (70 mg/kg. Se indujo EHNA con dieta hiperlipídica (Carbohidratos: 26%, Lípidos: 59% y Proteínas: 15% Calorías durante un período de 21 días, ad libitum. Luego, se administró el extracto acuoso de Gentianella alborosea por 4 días. Finalmente, se extrajeron los hígados para evaluar las alteraciones histopatológicas del parénquima hepático. Principales medidas de resultados: Se realizó el conteo microscópico de hepatocitos afectados con macrovacuolas, y los resultados fueron comparados mediante las pruebas de ANOVA (p<0,05 y HSD de Tukey (p<0,05. Resultados: Se encontró diferencias significativas (p<0.05 en el porcentaje de hepatocitos afectados entre los grupos dosis 1 (3.25 ± 2.27 y el control positivo (7.50 ± 3.76. Además, no se encontró diferencia significativa entre los grupos dosis 1 y dosis 2. Conclusiones: No se pudo determinar el efecto de Gentianella alborosea sobre la esteatosis hepática no alcohólica inducida por dieta hiperlipídica en ratas Holtzman hembra, por lo que se recomiendan estudios posteriores.

  1. EFECTO DE GENTIANELLA ALBOROSEA EN ESTEATOSIS HEPÁTICA NO ALCOHÓLICA INDUCIDA POR DIETA HIPERLIPÍDICA EN RATAS HOLTZMAN HEMBRAS

    Directory of Open Access Journals (Sweden)

    L. Ugaz-Soto

    2012-01-01

    Full Text Available Objetivo: Determinar el efecto del extracto de Gentianella alborosea como tratamiento contra esteatosis hepática no alcohólica (EHNA inducida por dieta hiperlipídica en ratas Holtzman hembras. Métodos: Diseño: Estudio experimental incompleto. Lugar: Universidad Nacional Mayor de San Marcos, Lima, Perú. Participantes: Ratas Holtzman hembras. Intervenciones: Se utilizó 32 ratas repartidas en 4 grupos (n=8 distribuidos aleatoriamente: grupo control negativo, control positivo con dieta hiperlipídica, dosis 1 (35 mg/kg y dosis 2 (70 mg/kg. Se indujo EHNA con dieta hiperlipídica (Carbohidratos: 26%, Lípidos: 59% y Proteínas: 15% Calorías durante un período de 21 días, ad libitum. Luego, se administró el extracto acuoso de Gentianella alborosea por 4 días. Finalmente, se extrajeron los hígados para evaluar las alteraciones histopatológicas del parénquima hepático. Principales medidas de resultados: Se realizó el conteo microscópico de hepatocitos afectados con macrovacuolas, y los resultados fueron comparados mediante las pruebas de ANOVA (p<0,05 y HSD de Tukey (p<0,05. Resultados: Se encontró diferencias significativas (p<0.05 en el porcentaje de hepatocitos afectados entre los grupos dosis 1 (3.25 ± 2.27 y el control positivo (7.50 ± 3.76. Además, no se encontró diferencia significativa entre los grupos dosis 1 y dosis 2. Conclusiones: No se pudo determinar el efecto de Gentianella alborosea sobre la esteatosis hepática no alcohólica inducida por dieta hiperlipídica en ratas Holtzman hembra, por lo que se recomiendan estudios posteriores.

  2. Pregancy-induced hypertension and birthweight Hipertensión inducida por el embarazo y peso de los productos al nacer

    Directory of Open Access Journals (Sweden)

    Nicolás Padilla Raygoza

    2013-03-01

    Full Text Available Objective. The objective of this work was to measure the existing association between preg­nancy-induced hypertension and birthweight at the Celaya General Hospital. Study design. Cross-sectional, observational, analytic study. Subjects: Registries of women admitted to the Celaya General Hospital for delivery during 2008. Variables: Pregnancy-induced hypertension (blood pressure of 140/90 mmHg or higher after 20 weeks of gestation, sub-classified as gestational hypertension (blood pressure of 140/90 mmHg or higher without proteinuria and toxemia (blood pressure of 140/90 mmHg or higher with proteinuria; birthweight ( 3 500 g. Statistical analysis: it was calculated the Analysis of Variance (ANOVA test was performed between the status of arterial hypertension and birthweight, and was adjusted using gestational age. Results. From the sample of 5 478 registries, 14.73% (n = 807 of women had pregnancy-induced hypertension; from them, 10.92% (n = 598 had gestational hypertension and 3.82% (n = 209 preclampsia/eclampsia. Newborns from hypertensive mothers had an average birthweight of 3 049.27 ± 600.22 g, while the birth­weight of newborns from normotensive mothers was 3 104.94 ± 502.57 g, considering: ANOVA F = 1.49, p = 0.00001: adjusted by gestational age, F = 1.51, p = 0.0168. Conclu­sion. Newborns of normotensive and gestational hypertensive mothers showed differences in birthweight; gestational age acted as a confounder.Objetivo. Medir la asociación que existe entre la hipertensión inducida por el embarazo y el peso al nacer de los neonatos, en el Hospital General de Celaya. Tipo de estudio. Observacio­nal, transversal y analítico. Sujetos: 1 Registros de mujeres embarazadas (n = 5 478, admi­tidas para su resolución obstétrica, en el Hospital General de Celaya durante el año 2008, y 2 registros del peso al nacer de los neonatos de estas mujeres. Variables: 1 Hipertensión inducida por el embarazo (presión arterial de 140/90 mmHg o

  3. Papel del endotelio en hipertensión inducida por el embarazo: ¿alteraciones comunes a las de la aterosclerosis?

    Directory of Open Access Journals (Sweden)

    Patricio López-Jaramillo

    2014-10-01

    Full Text Available La hipertensión inducida por el embarazo, cuya forma proteinúrica es denominada preeclampsia (PE, es una alteración que ocurre en el segundo trimestre del embarazo, y se caracteriza por la presencia de hipertensión y proteinuria. Durante el embarazo normal ocurren cambios fisiológicos adaptativos que incluyen insulino-resistencia (IR, hiperlipidemia, hipercoagulabilidad, inflamación y un estado circulatorio hiperdinámico. Estos cambios se expresan de una forma exagerada en las mujeres que desarrollan PE, alteraciones que están presentes también en el clúster de factores de riesgo que conforman el denominado síndrome metabólico (SM, el cual es un factor de riesgo para el desarrollo de diabetes mellitus tipo 2 (DM2 y enfermedad cardiovascular (ECV. En la presente revisión proponemos que la disfunción endotelial es la alteración común que explica la presencia de estas dos enfermedades comunes en América Latina.

  4. Cardiopatía inducida por estrés (Tako-Tsubo. Nueva hipótesis fisiopatológica

    Directory of Open Access Journals (Sweden)

    Carlos E. Gadda

    2010-01-01

    Full Text Available RESUMENLa miocardiopatía inducida por estrés tiene como factor común su casi exclusiva apariciónen mujeres posmenopáusicas que acaban de sufrir una situación de estrés de gran envergaduray que clínicamente presentan un evento coronario agudo muy similar a un infartoagudo de miocardio. Al ser estudiadas de urgencia por cateterismo o ecocardiografía, en elventrículo izquierdo se observa un área de acinesia o discinesia focalizada habitualmente enla “punta”, pero con coronarias angiográficamente normales o, a lo sumo, mínimamentecomprometidas.Las coronarias pronunciadamente flexuosas también son habituales en mujeresposmenopáusicas y las arterias con estas características, al acodarse en forma extrema,pueden generar kinkings. Durante una crisis adrenérgica, estos kinkings llegan a estrangularla arteria y comprometer el flujo más allá de la sístole, lo cual, sumado a los efectos de lascatecolaminas, generaría la alteración focal y transitoria de la contractilidad que caracterizaal Tako-Tsubo.Queda claro que para afirmar esta hipótesis deben explorarse futuros pacientes en búsquedade este patrón anatómico.REV ARGENT CARDIOL 2010;78:43-45.

  5. Efectos en ratas de los alcoholes de cera de abejas (D-002 sobre la colitis ulcerativa inducida por sulfato de dextrano y etanol

    Directory of Open Access Journals (Sweden)

    Vivian Molina-Cuevas

    Full Text Available Objetivos. Investigar los efectos del D-002, mezcla de seis alcoholes alifáticos primarios de alto peso molecular, obtenida de la cera de abejas (Apis mellifera, sobre la colitis ulcerativa (CU inflamatoria severa inducida por sulfato de dextrano (DSS y etanol en ratas (Ratus ratus. Materiales y métodos. Las ratas se distribuyeron aleatoriamente en seis grupos: un control cero al que no se provocó daño, y cinco a los que se les indujo la CU: un control negativo (vehículo, tres tratados con D-002 (25, 100 y 400 mg/kg y un control positivo con sulfazalacina (200 mg/kg (sustancia de referencia. Se cuantificaron las manifestaciones clínicas (variación del peso corporal, presencia de diarrea y de sangrado rectal, el puntaje de daño macroscópico e histológico, y la actividad de mieoloperoxidasa (MPO. Resultados. El tratamiento oral con D-002 (25, 100 y 400 mg/kg previno significativamente la disminución del peso corporal. La dosis de 400 mg/kg redujo la presencia de diarreas y sangrado rectal, aunque su comparación con el control negativo solo alcanzó significación estadística sobre las diarreas. El D-002 (25, 100 y 400 mg/kg redujo significativamente el puntaje de las lesiones macroscópicas (40,0; 43,3 y 47,2% de inhibición, respectivamente, el puntaje de daño histológico (31,5; 53,7 y 67,1% de inhibición, respectivamente y la actividad de MPO (73,2; 83,6 y 85,0% de inhibición, respectivamente, comparado con el grupo control negativo. La sulfazalacina redujo significativamente todas las variables estudiadas. Conclusiones. El D-002 (25, 100 y 400 mg/kg protegió significativamente la mucosa colónica en ratas con CU inflamatoria severa inducida por DSS y etanol.

  6. Efectos en ratas de los alcoholes de cera de abejas (D-002 sobre la colitis ulcerativa inducida por sulfato de dextrano y etanol

    Directory of Open Access Journals (Sweden)

    Vivian Molina-Cuevas

    Full Text Available RESUMEN Objetivos. Investigar los efectos del D-002, mezcla de seis alcoholes alifáticos primarios de alto peso molecular, obtenida de la cera de abejas (Apis mellifera, sobre la colitis ulcerativa (CU inflamatoria severa inducida por sulfato de dextrano (DSS y etanol en ratas (Ratus ratus. Materiales y métodos. Las ratas se distribuyeron aleatoriamente en seis grupos: un control cero al que no se provocó daño, y cinco a los que se les indujo la CU: un control negativo (vehículo, tres tratados con D-002 (25, 100 y 400 mg/kg y un control positivo con sulfazalacina (200 mg/kg (sustancia de referencia. Se cuantificaron las manifestaciones clínicas (variación del peso corporal, presencia de diarrea y de sangrado rectal, el puntaje de daño macroscópico e histológico, y la actividad de mieoloperoxidasa (MPO. Resultados. El tratamiento oral con D-002 (25, 100 y 400 mg/kg previno significativamente la disminución del peso corporal. La dosis de 400 mg/kg redujo la presencia de diarreas y sangrado rectal, aunque su comparación con el control negativo solo alcanzó significación estadística sobre las diarreas. El D-002 (25, 100 y 400 mg/kg redujo significativamente el puntaje de las lesiones macroscópicas (40,0; 43,3 y 47,2% de inhibición, respectivamente, el puntaje de daño histológico (31,5; 53,7 y 67,1% de inhibición, respectivamente y la actividad de MPO (73,2; 83,6 y 85,0% de inhibición, respectivamente, comparado con el grupo control negativo. La sulfazalacina redujo significativamente todas las variables estudiadas. Conclusiones. El D-002 (25, 100 y 400 mg/kg protegió significativamente la mucosa colónica en ratas con CU inflamatoria severa inducida por DSS y etanol.

  7. Disminución del daño oxidativo y efecto hipoglicemiante de la maca (Lepidium meyenii Walp en ratas con diabetes inducida por streptozotocina

    Directory of Open Access Journals (Sweden)

    María Elena Rodrigo

    2011-01-01

    Full Text Available Introducción: La maca es consumida desde tiempos ancestrales como parte de la dieta. Se le ha atribuido propiedades medicinales y se encuentra incluida en la medicina tradicional peruana. Estudios recientes describen que la admistración de maca reduce la glicemia en animales normoglicémicos, pero los mecanismos involucrados no están muy claros. Objetivos: Determinar el efecto hipoglicemiante y antioxidante de la harina de maca (Lepidium meyenii Walp del ecotipo amarillo, en ratas con diabetes inducida por estreptozotocina. Diseño: Experimental. Institución: Centro de Investigación de Bioquímica y Nutrición, Facultad de Medicina, Universidad Nacional Mayor de San Marcos, Lima, Perú. Material biológico: Harina de maca amarilla y ratas albinas Holtzmann machos con diabetes inducida. Intervenciones: Se administró la harina de maca amarilla a las ratas distribuidas en 4 grupos: grupo I control (solo dieta; II, harina de maca 4 g/día; III, harina de maca 6 g/día; y IV, dieta + glibenclamida 10 mg/kg de peso; el experimento duró 46 días. Se evaluó diariamente la glicemia y el peso; al final del experimento se determinó en sangre los niveles de insulina, parámetros de daño oxidativo (vitamina C y se midió la peroxidación lipídica (TBARS, como indicador del proceso oxidativo. Principales medidas de los resultados: Modificación de los niveles de glicemia, insulina, vitamina C y formación del complejo MDA-TBARS. Resultados: La administración de harina de maca en la dieta (4 a 6 g/día de animales diabéticos redujo la glicemia en 50%, incrementó los niveles de insulina 22% y mejoró los niveles de vitamina C respecto al grupo control. La administración de maca 4 g/día disminuyó el daño oxidativo, pues redujo la formación del complejo MDA-TBARS en 54% con respecto al grupo control. Conclusiones: La administración de harina de maca amarilla a animales diabéticos mejoró el metabolismo de la glucosa, regulando la glicemia y

  8. Los niveles de anticuerpos anti factor plaquetario 4-heparina y el índice 4T para trombocitopenia inducida por heparina

    Directory of Open Access Journals (Sweden)

    Marta E. Martinuzzo

    2012-02-01

    Full Text Available La trombocitopenia inducida por heparina (HIT es un efecto adverso del tratamiento con heparina, mediada por anticuerpos anti complejo factor plaquetario 4 (PF4-heparina (HPIA. La HIT es frecuentemente moderada pero pueden desarrollarse complicaciones trombóticas. El diagnóstico precoz es importante. La detección de HPIA por ELISA tiene alta sensibilidad pero baja especificidad (títulos bajos sin significación clínica. El índice de las 4T (índice 4T puede detectar pacientes con alto riesgo de HIT. El propósito del estudio fue correlacionar los niveles de HPIA y el índice 4T de un grupo de pacientes derivados a nuestro centro. Evaluamos 84 pacientes, 34 de ellos desarrollaron trombosis. Cada médico completó un cuestionario clínico que fue remitido con la muestra a nuestro centro. Los cuestionarios fueron analizados por un investigador externo y el índice 4T se calculó previamente al ensayo. Los HPIA se determinaron por un ELISA (Asserachrom HPIA que detecta los 3 isotipos, IgG, IgM e IgA, único reactivo disponible en Argentina. Los resultados se expresaron como porcentaje de absorbancia (%ABS. La correlación del índice 4T con los HPIA fue 0.472 (rho spearman, p < 0.001. Los pacientes con índice 4T ≥ 6 presentaban %ABS mayores que los ≤ 5 (67 vs. 39, p < 0.001. Aquéllos con trombosis presentaron títulos mayores que los que no la desarrollaron (%ABS 59 vs. 39, p = 0.017. En conclusión: Los títulos altos de HPIA medidos por ELISA, que detecta los 3 isotipos, correlacionaron claramente con el índice 4T ≥ 6 y fueron más frecuentes en los pacientes con trombosis, coincidiendo con lo ya descripto para ensayos de ELISA específicos para isotipo IgG.

  9. El estrés oxidativo: detonante fisiopatológico en la cardiomiopatía dilatada inducida por doxorrubicina

    Directory of Open Access Journals (Sweden)

    Ronal Aroche Aportela

    2011-12-01

    Full Text Available

    La cardiomiopatía dilatada inducida por doxorrubicina constituye uno de los principales efectos indeseables del tratamiento de pacientes con tumores malignos. El estrés oxidativo constituye uno de los mecanismos fisiopatológicos que desempeñan un papel fundamental en la instauración de la enfermedad causada por este antibiótico del grupo de las antraciclinas. La comprensión de estos mecanismos fisiopatológicos resulta de vital importancia para llevar a cabo estrategias de intervención farmacológica y nutricional para contribuir a palear los efectos nocivos de este antineoplásico. En el presente trabajo se realizó una actualización bibliográfica sobre el tema y se proponen ideas que pueden ser útiles para la comunidad científica que está enfrascada en el tratamiento de esta enfermedad crónica, y que se propone mejorar la calidad de vida de los pacientes que la padecen.

    Oxidative Stress: Pathophysiologic Trigger in Doxorubicin-induced Dilated Cardiomyopathy

    Doxorubicin-induced dilated cardiomyopathy is one of the main adverse effects in the treatment of patients with malignant tumours. Oxidative stress is one of the pathophysiological mechanisms that play a key role in the establishment of the disease caused by this anthracycline-type antibiotic. Understanding these pathophysiologic mechanisms becomes of vital importance in order to carry out pharmacological and nutritional intervention strategies to help paddling the harmful effects of this antineoplastic. As part of this research we conducted an updating literature review on the subject and provided ideas that can be useful for the scientific community engaged in the treatment of this chronic disease, which aims to improve the life quality of patients suffering from it.

  10. “Corrosión Inducida por Bacterias Sulfato Reductoras Termófilas de 60°C en la Unión Soldada del Acero API 5L- X60.”

    OpenAIRE

    Romero Romero, Justo Román

    2012-01-01

    En esta investigación se estudio el efecto de la corrosión inducida por Bacterias Sulfato Reductoras (BSR) termófilas a 60oC en el metal base (MB) y la unión soldada (US) del acero API X-60. Las bacterias sulfato reductoras fueron aisladas en el medio sólido postgate con la técnica de estriado, y fueron resembradas hasta obtener la misma morfología. El medio postgate fue seleccionado entre otros medios de cultivo, por el óptimo crecimiento que presento la BSR. Se preparar...

  11. Efectos del extracto de semillas de uva sobre la cistopatia diabética inducida por estreptozotocina en ratas

    OpenAIRE

    María Lourdes Arruzazabala; Yazmín Ravelo; Daisy Carbajal; Vivian Molina; Rosa Mas

    2010-01-01

    La diabetes por estreptozotocina (STZ) en ratas se produce como consecuencia de la necrosis subtotal de los islotes pancreáticos y provoca hiperglicemia, hipoinsulinemia, disminución de la ganancia en peso y aumento del peso de la vejiga, así como hipercontractilidad al carbacol por sobreexpresión de los ARNm-receptores muscarínicos M2 y M3 del detrusor y el urotelio. El extracto de semillas de uva (ESU), rico en flavonoides, ha mostrado efectos antioxidantes y neuroprotectores en modelos exp...

  12. Determinación de la profundidad y duración de la neutropenia inducida por ciclofosfamida en ratones hembras MPF de la cepa Udea: ICR(cd-1

    Directory of Open Access Journals (Sweden)

    Omar Vesga

    2004-02-01

    Full Text Available

    El modelo murino de infección del muslo emplea animales neutropénicos para poder determinar la eficacia intrínseca de los antibióticos in vivo. Sin embargo, no se ha definido el número de neutrófilos y la duración de la neutropenia inducida por ciclofosfamida (CFM intraperitoneal (IP, información fundamental
    para valorar la reproducibilidad y confiabilidad del modelo.

     

     

  13. Agroquímicos en Argentina: Genotoxicidad y citotoxicidad inducida por principios activos y sus formulaciones comerciales

    OpenAIRE

    Larramendy, Marcelo L; Molinari, Gabriela; González, Norma V; Pilili, Juan P; Candioti, Josefina Vera; Reigosa, Miguel A; Soloneski, Sonia

    2010-01-01

    Uno de los objetivos principales de nuestro laboratorio es evaluar comparativamente los efectos geno-citotóxicos ejercidos in vitro e in vivo sobre células de vertebrados por principios activos de agroquímicos y sus formulaciones comerciales de uso masivo en Argentina. Entre los mismos caben mencionarse, los herbicidas 2,4-D y 2,4-D DMA®, dicamba y Banvel®, el fungicida zineb y Azzurro®, los insecticidas carbofurán y Furadan®, pirimicarb y Aficida®, como también el endectocida ivermectina e I...

  14. Evaluación de la reacción acrosomal en espermatozoides humanos inducida por oligosacáridos

    Directory of Open Access Journals (Sweden)

    Angela Cadavid

    2004-02-01

    Full Text Available

    La capacitación es un proceso necesario que debe sufrir el espermatozoide para poder llevar a cabo la fertilización del ocito. Este evento se da durante su paso a través del tracto reproductor femenino, donde ocurre la interacción entre los espermatozoides y las células del epitelio oviductal, la cual es dependiente de carbohidratos. Adicionalmente, el espermatozoide necesita interactuar con una serie de moléculas presentes en la zona pelúcida, que permiten un reconocimiento específico entre el espermatozoide y el oocito. La interacción entre gametos es específica de especie; ésto indica que la zona pelúcida posee ligandos que son reconocidos por los espermatozoides y que éstos poseen receptores que le permiten la unión al oocito (1.

     

     

  15. Efecto antioxidante y hepatoprotector del Petroselinum sativum (perejil en ratas, con intoxicación hepática inducida por paracetamol

    Directory of Open Access Journals (Sweden)

    Luzmila Troncoso

    2007-12-01

    Full Text Available Objetivo: Determinar el efecto antioxidante y hepatoprotector del perejil (Petroselinum sativum en ratas con intoxicación hepática inducida por paracetamol. Lugar: Centro de Investigación de Bioquímica y Nutrición - "Laboratorio de Bioquímica Clínica y Nutricional "Leonidas Delgado Butrón" "Emilio Guija Poma" - Universidad Nacional Mayor de San Marcos. Lima, Perú. Diseño: Estudio analítico, transversal, prospectivo y cuasi-experimental. Material: Ratas albinas Holtzman machos adultas. Métodos: Se utilizó 40 ratas de 2 meses de edad, con pesos entre 280 y 320 g, distribuidas aleatoriamente en cuatro grupos de 10 animales cada uno. Todos los grupos recibieron la misma dieta y agua ad libitum, además de los respectivos tratamientos, los cuales fueron administrados por vía oral diariamente, durante 5 días: paracetamol (administrado en una dosis de 200 mg/kg de peso corporal para inducir la intoxicación hepática y, al mismo tiempo, un hepatoprotector, ya fuera farmacológico (fármaco hepatoprotector (FHP: Purinor® o natural (perejil; además, un grupo de paracetamol solo y otro de control. Al término del período experimental, los animales fueron sacrificados. En suero sanguíneo se determinó aspartato aminotransferasa (AST, alanina aminotransferasa (ALT, gamma glutamil transferasa (GGT, grupos sulfhidrilo, proteínas totales y albúmina sérica; y en el homogenizado citosólico de hígado, fracción posmitocondrial, se determinó superóxido dismutasa, catalasa, glucosa-6-fosfato deshidrogenasa, grupos sulfidrilo, especies reactivas al ácido tiobarbitúrico (TBARS o radicales libres y proteínas. Además, se realizó el estudio histopatológico del hígado, para identificar signos de necrosis y signos de regeneración posnecrótica. Principales medidas de resultados: Efecto antioxidante y hepatoprotector del perejil. Resultados: El perejil mostró un mejor efecto hepatoprotector que el FHP, frente a la acción nociva del

  16. Modificaciones hematológicas inducidas por eritropoyetina frente a hipoxia normobárica intermitente Hematologic changes induced by erythropoietin versus intermittent normobaric hypoxia

    Directory of Open Access Journals (Sweden)

    F. Sanchis-Gomar

    2010-12-01

    Full Text Available

    Publicaciones recientes reflejan la preocupación de las autoridades antidopaje por el uso de sistemas simuladores de altitud y la posibilidad de considerarlos métodos dopantes. El objetivo de nuestro estudio fue el de comparar las modificaciones hematológicas inducidas por dos tratamientos con eritropoyetina recombinante humana (rHuEpo a diferentes dosis, frente a un protocolo de hipoxia normobárica intermitente (HNI en un modelo animal.
    Veinticuatro ratas Wistar macho jóvenes fueron divididas en 3 grupos experimentales: grupo sometido a HNI (12h pO2 12% /12h pO2 21% (n=8; grupo tratado con una dosis de 300 UI de rHuEpo (n=8 y grupo tratado con 500 UI de rHuEpo (n=8. Se extrajeron dos muestras de sangre a cada uno de los grupos experimentales (antes y después de los tratamientos. Nuestros resultados muestran incrementos muy similares, y estadísticamente significativos, en los valores de hemoglobina, de hematocrito y de reticulocitos, tanto en el grupo HNI como en el grupo tratado con 300 UI de rHuEpo tras los 15 días de tratamiento. El tratamiento con 500 UI de rHuEpo produjo un incremento significativamente mayor.
    La principal conclusión de nuestro estudio es que las modificaciones de los parámetros hematológicos obtenidas mediante un protocolo de HNI son similares a las obtenidas con un tratamiento con 300 UI de rHuEpo.
    Palabras clave: Hemoglobina, hematocrito, reticulocitos, dopaje

    Recent publications reflect the anti-doping authorities’ concern about the use of altitude simulator systems, since these technologies could be considered as doping methods. The major aim of our study was to compare the effect of two different rHuEpo treatments with a normobaric intermittent hypoxic (NIH protocol regarding the modifications of hemoglobin, hematocrit and reticulocytes values in an animal model. Although these hematological parameters are of secondary nature, some international sport federations

  17. Análisis proteómico de la resistencia inducida por micorrización al patógeno foliar Sclerotinia sclerotiorum en frijol (Phaseolus vulgaris l.)

    OpenAIRE

    Quintero Zamora, Edalhí

    2014-01-01

    En los últimos años se han reportado diversos estudios sobre la resistencia inducida por micorrización al ataque de patógenos, en éstos se han determinado los cambios de expresión de genes y proteínas que ocurren en las raíces de plantas colonizadas por hongos micorrízicos arbusculares. Recientemente, se han iniciado estudios para entender cómo afecta esta interacción a la parte aérea de la planta. En nuestro grupo de investigación se llevó a cabo el estudio del efecto de la micorrizaci...

  18. Efectos del policosanol en los modelos de pleuresía inducida por carragenina y granuloma por algodón

    Directory of Open Access Journals (Sweden)

    Daisy Carbajal Quintana

    Full Text Available Introducción: el policosanol, mezcla de alcoholes alifáticos primarios superiores purificada de la cera de caña, inhibe la actividad de la cicloxigenasa-1 (COX-1 in vitro, efecto que pudiera sustentar su acción antiagregante plaquetaria. Sin embargo, sus posibles efectos en modelos experimentales de inflamación no se habían investigado. Objetivo: determinar el efecto antinflamatorio in vivo del policosanol en un modelo de inflamación aguda (pleuresía por carragenina y crónico (granuloma por algodón. Métodos: se distribuyeron las ratas Sprague Dawley en siete grupos para el modelo de inflamación aguda: un control negativo (vehículo y seis a los que se les indujo la inflamación: un control positivo (vehículo, cuatro tratados con policosanol (50-800 mg/kg y uno con aspirina (100 mg/kg. Se cuantificaron a las 5 h el volumen de exudado pleural, la concentración de proteínas y actividad de la enzima mieloperoxidasa. Se distribuyeron las ratas en seis grupos para el modelo crónico: un control (vehículo, cuatro tratados con policosanol (50-800 mg/kg y uno con aspirina (100 mg/kg. Se extrajo el granuloma para determinar los pesos húmedo y seco seis días después de implantado el pellet. Resultados: dosis orales únicas de policosanol (200, 400 y 800 mg/kg redujeron significativa y moderadamente el volumen, la actividad de la enzima mieloperoxidasa (» 12 % y la concentración de proteínas (» 20 % del exudado pleural, mientras la aspirina redujo estos indicadores en un 35,3, 19,9 y 19,1%, respectivamente. La administración oral de policosanol (400 y 800 mg/kg durante 6 días disminuyó significativa y moderadamente el peso húmedo del granuloma (16,4 y 16,2 %, y el peso seco (28,4 y 34,4 %. La aspirina 100 mg/kg redujo estas variables en un 18,5 % (peso húmedo y 34,4 % (peso seco. Ambos tratamientos produjeron mayores reducciones del peso seco que del peso húmedo del granuloma. Conclusiones: la administración oral de policosanol

  19. Estudio de la influencia del Cu y Ni en la cinética de transformación martensítica inducida por deformación en fundiciones nodulares austemperadas

    Directory of Open Access Journals (Sweden)

    Guzmán, D.

    2013-06-01

    Full Text Available The objective of this work was to study the influence of copper and nickel on the kinetics of strain-induced martensite in austempered ductile cast iron. The austempered ductile cast irons were obtained from two ductile cast irons with different copper and nickel contents by means of austempering treatment. The deformation was carried out using a rolling mill. The quantification of the phases was obtained by means of X ray diffraction, while the microstructural characterization was carried out using optical and scanning electron microscopy. It was proved that the kinetics of strain-induced martensite in austempered ductile cast iron can be modeled using the equations proposed by Olson- Cohen and Chang et al. Based on the results obtained from these analyses, it is possible to conclude that the nickel and copper complicate the martensite transformation because these elements increase the staking fault energy of the austenite and its thermodynamic stability.El objetivo de este trabajo fue estudiar el efecto del cobre y níquel en la cinética de la transformación martensítica inducida por deformación en fundiciones nodulares austemperadas. Las fundiciones utilizadas se fabricaron mediante austemperado, a partir de dos fundiciones nodulares, con diferentes contenidos de cobre y níquel. La deformación se realizó en un laminador de rodillo. La cuantificación de las fases se realizó mediante difracción de rayos X, mientras que la caracterización microestructural se efectuó utilizando microscopía óptica y electrónica de barrido. Se comprobó que la cinética de transformación martensítica inducida por deformación en fundiciones nodulares austemperadas puede ser modelada mediante los modelos de Olson-Cohen y Chang et al. Basándose en los resultados obtenidos de estos ajustes, se concluye que tanto el níquel como el cobre dificultan la transformación martensítica debido a que estos elementos aumentan la energía de falla de

  20. El coactivador de receptores nucleares RAC3 tiene un rol protector de la Apoptosis inducida por distintos estímulos RAC3 nuclear receptor co-activator has a protective role in the apoptosis induced by different stimuli

    Directory of Open Access Journals (Sweden)

    Georgina P. Coló

    2007-10-01

    Full Text Available RAC3 pertenece a la familia de coactivadores de receptores nucleares p160, y se encuentra sobreexpresado en varios tumores. Demostramos previamente que RAC3 es coactivador del factor de transcripción anti-apoptótico NF-kapa;B. En este trabajo investigamos su rol en la apoptosis inducida por H2O2 en una línea celular no tumoral derivada de riñón embrionario humano (HEK293, y por el ligando inductor de apoptosis relacionado a TNF (TRAIL en una línea de leucemia mieloide crónica humana (K562, naturalmente resistente a la muerte por este estímulo. Observamos que las células tumorales K562 poseen niveles altos de RAC3 comparados con las células no tumorales HEK293. La sobreexpresión normal de coactivador o por transfección, inhibe la apoptosis mediante una disminución de la activación de caspasas, translocación del factor inductor de apoptosis (AIF al núcleo, aumento de la actividad de NF-kapa;B y las quinasas AKT y p38 y disminución de la quinasa ERK. Lo opuesto fue observado por disminución de RAC3 mediante la técnica de ARN interferente (RNAi en K562, aumentando así la apoptosis inducida por TRAIL. Estas evidencias sugieren que una sobreexpresión de RAC3 contribuye al desarrollo de tumores, participando en las cascadas que controlan la muerte celular por mecanismos no estrictamente dependientes de hormonas esteroideas y/o de acetilación, constituyendo esto un posible blanco de ataque para el tratamiento de tumores.RAC3 belongs to the family of p160 nuclear receptors coactivators and it is over-expressed in several tumors. We have previously shown that RAC3 is a NF-kappa;B coactivator. In this paper, we investigated the role of RAC3 in cell-sensitivity to apoptosis, using H2O2 in the human embryonic kidney cell line (HEK293, and tumor necrosis factor-related apoptosis inducing ligand (TRAIL in a human chronic myeloid leukemia cell line (K562 naturally resistant to TRAIL. We observed that the tumoral K562 cells have high levels

  1. Mitogen activated protein kinases blockade improves lipopolysaccharide-induced ileal motor disturbances El bloqueo de las proteínas cinasas activadas por mitógenos mejora las alteraciones motoras inducidas por el lipopolisacárido en íleon

    Directory of Open Access Journals (Sweden)

    Sergio Gonzalo

    2012-06-01

    Full Text Available Background: several diseases such as sepsis can affect the ileum. Lipopolysaccharide (LPS, an endotoxin present in the cell wall of gram negative bacteria, is a causative agent of sepsis. Objectives: the aims of this study were: a to investigate the role of mitogen activated protein kinases (MAPKs in the effect of LPS on the acetylcholine-induced contractions of rabbit ileum; and b to study the localization of MAPKs in the ileum. Material and methods: ileal contractility was studied in an organ bath and MAPKs were localized by immunohistochemistry. Results: acetylcholine-induced contractions decreased with LPS. SB203580, SP600125 and U0126 blocked the effect of LPS on the acetylcholine-induced contractions. Phosphorylated p38 and ERK were detected in neurons of myenteric plexus and phosphorylated p38 and JNK in smooth muscle cells of ileum. Conclusion: we can suggest that p38, JNK, and ERK MAPKs are involved in the mechanism of action of LPS in the ileum.Introducción: varias enfermedades como la sepsis pueden afectar al íleon. El lipopolisacárido (LPS, una endotoxina presente en la pared celular de las bacterias gram-negativas, es un agente causal de la sepsis. Objetivos: los objetivos del presente estudio fueron: a investigar el papel de las proteína cinasas activadas por mitógenos (MAPKs en los efectos del LPS en las contracciones inducidas por acetilcolina en el íleon de conejo; y b estudiar la localización de las MAPKs en el íleon. Material y métodos: la contractilidad ileal se estudió en un baño de órganos y las MAPKs se localizaron mediante inmunohistoquímica. Resultados: el LPS disminuyó las contracciones inducidas por acetilcolina. El SB203580, el SP600125 y el U0126 bloquearon los efectos del LPS sobre las contracciones inducidas por acetilcolina. La p38 y la ERK fosforiladas se detectaron en las neuronas del plexo mientérico y la p38 y la JNK fosforiladas en las células del músculo liso del íleon. Conclusi

  2. Actividad inducida por androsterona y hemisuccinato de androsterona sobre la presión de perfusión y la resistencia vascular

    Directory of Open Access Journals (Sweden)

    Lauro Figueroa

    2009-12-01

    Conclusiones. Los efectos inducidos por androsterona y hemisuccinato de androsterona sobre la presión de perfusión y la resistencia vascular pueden depender de su estructura química. En el caso de la actividad ejercida por el análogo de androsterona, podría involucrar la interacción del esteroide-receptor androgénico e, indirectamente, la activación del canal de calcio y, consecuentemente, inducir variaciones en la presión de perfusión.

  3. Respuesta inmune y expresión de genes en el camarón blanco (Litopenaeus vannamei) inducida por inmunoestimulantes microbianos

    OpenAIRE

    Moreno Herrera, Jesús Tomás

    2014-01-01

    En este trabajo se evaluó el efecto inmunoestimulante de bacterias ácido lácticas y levaduras muertas por calor en Litopenaeus vannamei, cultivado en el laboratorio. La mezcla inmunoestimulante (MI) en polvo se adicionó en el alimento. Se realizó un bioensayo de 26 días en tinas de plástico con 80 L de agua de mar filtrada, aireación constante y 10 organismos por tina. La alimentación se realizó dos veces al día, la limpieza diariamente y la determinación de parámetros fisicoquímicos cada 3 d...

  4. Reacción posquirúrgica del lecho vascular inducida por el campo magnético de ultra-alta frecuencia

    Directory of Open Access Journals (Sweden)

    Armando Hidalgo de Paz

    1995-06-01

    Full Text Available En 82 ratas blancas adultas se estudió el efecto posoperatorio del campo magnético de ultra- -alta frecuencia (CMUAF sobre el volumen del lecho intramuscular, durante el período de formación de colaterales. El CMUAF se aplicó con el aparato portátil UVCHE-30, con frecuencia de 40,68 MHz y potencias fijas de salida de 15 y 30 W. Luego de seccionar quirúrgicamente las arterias femorales, se aplicó el campo magnético por 2, 6, 10 y 16 semanas. En estos plazos se inyectó mezcla de tinta china-gelatina en el lecho vascular y se obtuvieron cortes micrométricos que se transparentaron y fueron posteriormente leídos por microfotometría. Se observó un marcado aumento del volumen del lecho vascular intramuscular por acción del CMUAF, particularmente en los períodos de 2 y 6 semanas posteriores al inicio del tratamiento. También se evidenció mayor reacción vascular a la acción del CMUAF con potencia de 15 W, en comparación con los resultados en 30 W

  5. Efecto del estrés durante diferentes etapas del ciclo vital sobre el desarrollo de obesidad inducida por la dieta

    OpenAIRE

    Paternain, L. (Laura); Martinez, J.A. (José Alfredo); Campión-Zabalza, J. (Javier)

    2016-01-01

    La creciente prevalencia de la obesidad no puede ser atribuible únicamente a factores genéticos o a una mala nutrición como pueden ser las dietas altas en grasa, sino también al estilo de vida y a factores ambientales adversos. Dentro del estilo de vida, la sociedad actual se caracteriza por tener un ritmo acelerado, lo que produce una elevación de la tasa de estrés en la población. Este aumento paralelo tanto de las tasas de obesidad como del estrés, hace necesario el estudio de la interacci...

  6. Modulación del tono vascular por la sobre-expresión de receptores a canabinoides CB1 y CB2 en arterioesclerosis inducida en ratas

    OpenAIRE

    Espinoza P., María Rosa

    2013-01-01

    La arteriosclerosis, es un proceso degenerativo responsable de la mayor parte de las enfermedades cardiovasculares, es una enfermedad compleja que se produce a partir de múltiples factores de riesgo. Se ha observado que los compuestos derivados de la planta cannabis sativa provocan efectos vasorelajantes por medio de receptores específicos CB1 y CB2. ACPA y JWH 133 son potentes agonistas a estos receptores, se desconoce el papel que desempeñan en la arteriosclerosis provocando una relajación ...

  7. Prevención, diagnóstico y tratamiento de la cardiotoxicidad inducida por quimioterapia: ¿qué estamos haciendo?

    Directory of Open Access Journals (Sweden)

    Lázaro de la Cruz Avilés

    2012-09-01

    Full Text Available Las enfermedades del corazón y los tumores malignos constituyen las dos primeras causas de muerte en Cuba, con tasas de mortalidad de 197,5 y 193,6 por 100 000 habitantes, respectivamente, en el año 2011. En Cienfuegos los tumores malignos fueron la primera causa de muerte con una tasa de 115,2 seguida de las enfermedades del corazón con 102,6 por 100 000 habitantes. Las mejoras alcanzadas en la detección y el tratamiento del cáncer han dado origen a una nueva cohorte de pacientes que alcanzan una supervivencia suficiente para que puedan aparecer complicaciones cardíacas derivadas del tratamiento. Lamentablemente, el abundante conocimiento sobre las vías bioquímicas involucradas en el tratamiento dirigido del cáncer no se ha visto acompañado de un conocimiento paralelo de las consecuencias cardíacas de su modulación.

  8. Compactación inducida por el tránsito vehicular sobre un suelo en producción hortícola Induced compaction by the vehicular traffic in a soil for horticultural crop production

    Directory of Open Access Journals (Sweden)

    Antonino Marcelo Terminiello

    2000-01-01

    Full Text Available Se realizaron ensayos en campo con el objeto de caracterizar el estado de compactación de un suelo en producción hortícola inducida por el tránsito, luego del desarrollo del ciclo de un cultivo de repollo (Brassica oleracea L. grupo capitata y su incidencia sobre el rendimiento. Se efectuaron determinaciones de resistencia a la penetración, densidad aparente y humedad gravimétrica sobre el suelo y biomasa aérea al finalizar el ciclo del cultivo en los sectores de mayor y menor número de pasajes de vehículos. Los valores de resistencia a la penetración fueron de 1,7 y 1,3 MPa, significativamente mayores para el tratamiento de más de 7 y 3 pasadas respectivamente en el rango de profundidad de 0-100 mm . No se manifestaron diferencias en el parámetro densidad aparente en la totalidad del perfil. Se encontraron diferencias estadísticamente significativas en biomasa aérea, para el tratamiento de 3 pasadas (1902.6 g planta-1, en relación al de mas de 7 pasadas (1447,9 g planta-1. El pasaje repetido sobre los surcos originan incrementos en la resistencia a la penetración a nivel superficial. El peso fresco y la materia seca del cultivo son afectados por el número de pasadas de los tractores y máquinas agrícolas.Field test were carried out with the objective of characterizing the state of compaction in horticultural soil induced by traffic, after the development of a cabbage crop (Brassica oleracea L. group capitata cycle, and its incidence on yield. Measurements of penetration resistance, bulk density, and moisture content in soil were made and aeread biomass at the end of the cycle crop in sectors with larger and smaller number of vehicles passes. Values of penetration resistance of 1.7 and 1.3 MPa were found for treatment with more than 7 passes and 3 passes respectively in the depth range of 0-100 mm. No significant differences were found in bulk density parameter in the entire soil profile. Statistically significant differences

  9. Efecto antioxidante del extracto acuoso de propóleos sobre la hepatotoxicidad inducida por el octilfenol en ratas macho Antioxidant effect of aqueous extract of propolis on hepatotoxicity induced by octylphenol in male rats

    Directory of Open Access Journals (Sweden)

    Eman M Saleh

    2012-12-01

    Full Text Available El 4-terc-octilfenol (4-terc-OP es un alquilfenol que afecta a la salud humana mediante la estimulación de la producción de radicales libres. El extracto acuoso de propóleos es un producto natural rico en favonoides que tienen actividad antioxidante. Este estudio fue diseñado para investigar la capacidad del extracto de propóleos de reducir la hepatotoxicidad inducida por el 4-terc-OP en ratas macho. Los animales fueron asignados a 5 grupos y tratados durante 6 semanas. Grupo 1: control; grupo 2: 100 mg de 4-terc-OP/kg/día; grupo 3: 100 mg de extracto de propóleos/kg/día; grupo 4: 100 mg de 4-terc-OP/ kg/día más 100 mg de extracto de propóleos/kg/día, grupo 5: 100 mg de 4-terc-OP/kg/día durante 6 semanas, seguidos de 100 mg de extracto de propóleos/kg/día durante 6 semanas. El grupo 4-terc-OP mostró niveles signifcativamente elevados de AST, ALT, ALP, GGT, bilirrubina, creatinina, urea, lípidos totales, colesterol total, triglicéridos, LDL-C y MDA, con una disminución signi-fcativa de proteínas totales, albúmina, globulina, HDL-C, la capacidad antioxidante total, SOD, CAT y GST, en comparación con el grupo control. La administración de extracto de propóleos, ya sea solo o combinado con 4-terc-OP redujo la hepatotoxicidad inducida por 4-terc-OP. Los estudios de fragmentación del ADN apoyan el efecto deletéreo observado por el tratamiento con 4-terc-OP y el efecto protector del extracto de propóleos, sobre las proteínas y las enzimas celulares hepáticas. Los resultados histopatológicos revelaron la hepatotoxicidad por 4-terc-OP y efecto protector inducido por el extracto de propóleos. En conclusión, el extracto de propóleos podría reducir el daño hepático y los efectos celulares de toxicidad en las células del hígado inducidos por 4-terc-OP.4-tertiary-octylphenol (4-tert-OP is an alkylphenol that affects human health by stimulating free radical production. Aqueous propolis extract is a natural product rich in

  10. Aspergilosis pulmonar secundaria a neutropenia inducida por metimazol: reporte de un caso Pulmonary aspergillosis due to methimazole-induced neutropenia: a case report

    Directory of Open Access Journals (Sweden)

    Miguel E. Pinto

    2012-06-01

    Full Text Available Se reporta el caso de una paciente de 48 años de edad con diagnóstico reciente de enfermedad de Graves, quien acudió a emergencia por presentar fiebre, palpitaciones y dolor faríngeo. Su tratamiento regular incluía metimazol. Al ingreso, los análisis mostraron TSH suprimido, T4 libre elevado y neutropenia. La paciente fue hospitalizada, se administraron antibióticos y factor estimulante de colonia. Después de diez días de tratamiento, la paciente presentó leucocitosis, fiebre y hemoptisis. La tomografía de tórax mostró una cavidad con múltiples nódulos en el lóbulo superior derecho. Los cultivos fueron positivos a Aspergillus fumigatus y Aspergillus flavus. Se inició tratamiento con anfotericina B y luego se cambió a voriconazol, a pesar de lo cual no hubo mejoría del cuadro. La paciente falleció por falla multiorgánica.A 48-year old woman with a recent diagnosis of Graves’ disease arrived at the emergency room with fever, palpitations, and a sore throat. Her regular treatment included methimazole. On admission, laboratory results showed suppressed TSH, elevated free thyroxine, and neutropenia. She was admitted and started on antibiotics and granulocyte-macrophage colony stimulating factor (gm-csf. After ten days, the patient developed leukocytosis, fever, and hemoptysis. Chest CT scan showed a lung cavity with multiple nodules in the upper right lobe. Cultures from a lung biopsy were positive for Aspergillus Fumigatus and Aspergillus Flavus. Amphotericin B was started but then switched to voriconazole, with both treatments failing to result in clinical improvement. The patient died of multi-organ failure.

  11. Tratamiento de agua potable por filtración inducida en una laguna costera en el sur de Brasil Bank filtration drinking water treatment in a costal lagoon in south Brazil

    Directory of Open Access Journals (Sweden)

    Luis Guillermo Romero Esquivel

    2012-12-01

    Full Text Available La filtración inducida (FI consiste en obtener agua potable de pozos situados en acuíferos de aluvión u otro tipo de depósitos no consolidados conectados hidráulicamente con una fuente de agua superficial. La posibilidad de aplicar esta técnica en las riberas de la laguna Lagoa do Peri, Brasil, se evaluó a nivel piloto. Por medio de observación y de análisis granulométricos se determinó que el fondo de la laguna y el acuífero aledaño presentan una textura arenosa. Además, ensayos de permeámetro de carga constante, de tubo de carga variable y de bombeo, mostraron que la conductividad hidráulica en las mismas zonas se encuentra cercana a 10-4 m/s, misma magnitud encontrada en otras latitudes donde la FI se aplica con éxito. El agua captada en un pozo a 20 m de la Lagoa do Peri presentó valores de turbidez y color aparente acordes con los patrones de calidad locales. Se observó un aumento en la dureza y la alcalinidad, atribuido a la erosión de los materiales del subsuelo, sin llegar a superar lo estipulado en la legislación. Finalmente, el agua producida por la FI mostró ser de mejor calidad en términos de turbidez y color aparente que el agua de la laguna tratada por filtración directa en una estación de tratamiento (ETA ubicada en el lugar. El agua producida por la FI presentó condiciones anóxicas que harían necesario el postratamiento por aireación y filtración, proceso en el cual se podría aprovechar la infraestructura de la ETA existente.Bank filtration (BF consists in obtaining drinking water from wells in alluvial aquifers or other unconsolidated deposits hydraulically connected with a surface water source. The possibility of applying this technique was evaluated in a pilot scale on the banks of the Lagoa do Peri lagoon, Brazil. Observation and grain size analysis showed that the bottom of the lagoon and the adjacent aquifer have sandy texture. In addition, tests of constant head permeameter, standpipe falling

  12. Osteonecrosis de los maxilares inducida por bifosfonatos: prevención y actitud terapéutica Bisphosphonate induced osteonecrosis of the jaws: prevention and therapeutic approach

    Directory of Open Access Journals (Sweden)

    F.J. Barrientos Lezcano

    2007-10-01

    Full Text Available Introducción. La osteonecrosis maxilar o mandibular por bifosfonatos puede convertirse en una epidemia debido a la amplia difusión de estos fármacos entre la población. Material y método. Se muestra un protocolo para la prevención y el tratamiento de esta enfermedad. Se presentan tres casos de osteonecrosis maxilar/mandibular. Resultados. Es difícil lograr una curación completa; sin embargo es posible detener la progresión de la enfermedad. Discusión. La cirugía y la suspensión de la terapia con bifosfonatos han demostrado poca utilidad. Los antibióticos y los enjuagues con clorhexidina son las únicas medidas eficaces. Conclusiones. Es imprescindible una planificación adecuada previa a la instauración del tratamiento con bifosfonatos. Ante una osteonecrosis establecida, la actitud debe ser conservadora.Introduction. Bisphosphonate-induced osteonecrosis of the jaws might reach epidemic proportions due to the widespread use of this therapy. Materials and methods. A protocol for prevention and treatment of this pathology is shown. Three clinical cases are reported. Results. It is quite difficult to reach restitutio ad integrum, but stopping the progress of the disease is possible. Discussion. Surgical treatment and cessation of bisphosphonate therapy are of no use. Only antibiotics and oral chlorhexidine have shown some benefits. Conclusions. An accurate preventive attitude is mandatory prior to undergoing bisphosphonate therapy. If osteonecrosis of the jaws is present, management should be conservative.

  13. Determinación del índice de resistencia a la insulina mediante homa y su relación con el riesgo de hipertensión inducida por el embarazo Insulin resistance index assessment by homa and its relation with the risk of pregnancy induced hypertension

    Directory of Open Access Journals (Sweden)

    Jesús Sierra-Laguado

    Full Text Available Objetivo: investigar si el grado de resistencia a la insulina determinado por el índice HOMA, predice de manera temprana el desarrollo de hipertensión inducida por el embarazo en gestantes colombianas. Diseño-métodos: se realizó un estudio de casos y controles anidado en una cohorte prospectiva de 438 mujeres primigestantes, normotensas y con edad gestacional menor de 30 semanas. Se determinó el índice HOMA a partir de la medición de glucemia e insulina plasmática en ayunas, por métodos de glucosa oxidasa y quimioluminiscencia, respectivamente. Resultados: veintitrés mujeres desarrollaron hipertensión inducida por el embarazo (5,25%. Se seleccionaron de forma aleatoria dos embarazadas normotensas como controles por cada caso, pareadas por edad materna y gestacional al momento de su inclusión. Las mujeres que posteriormente desarrollaron hipertensión inducida por el embarazo presentaron mayores niveles de HOMA (1,48 ± 0,98 vs. 0,96 ± 0,70, pObjective: to assess whether insulin resistance determined by homeostatic model assessment (HOMA is an early predictor of the development of pregnancy induced hypertension in Colombian pregnant women. Methods: we conducted a nested case control study in a prospective cohort of four hundred and thirty eigth normotensive primigravidae women, with gestational age < 30 weeks. The HOMA was calculated using fasting plasma concentrations of glucose and insulin, determined by glucose-oxidase and chemoluminiscence methods, respectively. Results: twenty-three pregnant women developed pregnancy induced hypertension (5.25%. Two normotensive pregnant women were selected as controls for each case, matched by gestational and maternal age at enrollment. The women who subsequently developed pregnancy induced hypertension had higher levels of HOMA (1.48 ± 0.98 vs 0.96 ± 0.70, p<0.001, which was associated with an increased risk of developing pregnancy induced hypertension (OR: 3.8, IC95%: 1.1-12.8 p=0

  14. Corrosion detection and monitoring in steam generators by means of ultrasound; Deteccion y monitoreo de corrosion por medio de ultrasonido en generadores de vapor

    Energy Technology Data Exchange (ETDEWEB)

    Chacon Nava, Jose G; Calva, Mauricio [Instituto de Investigaciones Electricas, Cuernavaca (Mexico); Fuentes Samaniego, Raul [Universidad Autonoma de Nuevo Leon (Mexico); Peraza Garcia, Alejandro [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1988-12-31

    The tube and component failures in steam generators due to corrosion cause huge economical losses. In this article the internal corrosion processes (hydrogen attack) and high temperature corrosion are described, as well as the ultrasound techniques used for its detection. The importance of obtaining corrosion rates, which are fundamental parameters for the detection of the tube`s residual life. The purpose is to prevent possible failures that would diminish the power plant availability. [Espanol] Las fallas de tuberia en componentes de generadores de vapor debidas a corrosion ocasionan considerables perdidas economicas. En este articulo se describen los procesos de corrosion interna (ataque por hidrogeno) y corrosion en alta temperatura, asi como tecnicas de ultrasonido empleadas para su deteccion. Se destaca la importancia de obtener valores de velocidad de corrosion, que es un parametro fundamental para la determinacion de la vida residual de tuberias. El proposito es poder prevenir posibles fallas que disminuyan la disponibilidad de centrales termoelectricas.

  15. Corrosion detection and monitoring in steam generators by means of ultrasound; Deteccion y monitoreo de corrosion por medio de ultrasonido en generadores de vapor

    Energy Technology Data Exchange (ETDEWEB)

    Chacon Nava, Jose G.; Calva, Mauricio [Instituto de Investigaciones Electricas, Cuernavaca (Mexico); Fuentes Samaniego, Raul [Universidad Autonoma de Nuevo Leon (Mexico); Peraza Garcia, Alejandro [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1987-12-31

    The tube and component failures in steam generators due to corrosion cause huge economical losses. In this article the internal corrosion processes (hydrogen attack) and high temperature corrosion are described, as well as the ultrasound techniques used for its detection. The importance of obtaining corrosion rates, which are fundamental parameters for the detection of the tube`s residual life. The purpose is to prevent possible failures that would diminish the power plant availability. [Espanol] Las fallas de tuberia en componentes de generadores de vapor debidas a corrosion ocasionan considerables perdidas economicas. En este articulo se describen los procesos de corrosion interna (ataque por hidrogeno) y corrosion en alta temperatura, asi como tecnicas de ultrasonido empleadas para su deteccion. Se destaca la importancia de obtener valores de velocidad de corrosion, que es un parametro fundamental para la determinacion de la vida residual de tuberias. El proposito es poder prevenir posibles fallas que disminuyan la disponibilidad de centrales termoelectricas.

  16. Tiroiditis autoinmune inducida por interferón en pacientes con infección por virus de la hepatitis C. Interferon-induced autoimmune thyroiditis in a patient with hepatitis C virus infection

    Directory of Open Access Journals (Sweden)

    José L. Pinto

    2011-06-01

    Full Text Available Se reporta el caso de un varón de 43 años de edad, sin antecedentes patológicos de importancia, que acudió por elevación asintomática de la alanino aminotransferasa (ALT. El paciente negó ser bebedor crónico de alcohol. Se hizo el diagnóstico serológico de infección activa por hepatitis C y la biopsia de hígado reveló inflamación crónica activa. Con estos resultados, se inició tratamiento con interferón-alfa y ribavirina. Durante el tratamiento de 48 semanas, el paciente presentó anticuerpos antitiroideos positivos con variaciones en sus niveles de tirotropina (TSH y hormonas tiroideas. En el seguimiento postratamiento, el paciente continuó con hipertiroidismo por enfermedad de Graves. La tiroiditis autoinmune es una complicación frecuente del uso de interferón en pacientes con hepatitis C. En algunos casos se presenta como hipertiroidismo por enfermedad de Graves. Se debe evaluar la función tiroidea y los anticuerpos antitiroideos antes y durante el tratamiento con interferón.A 43 year old man presented with asymptomatic elevation of alanine aminotransferase (ALT and no relevant past history. The patient denied being a chronic alcohol drinker. Work-up revealed an active hepatitis C, and liver biopsy showed active inflammation. Treatment was started with interferon-alfa and ribavirin. During the 48 weeks of treatment, the patient developed positive thyroid antibodies with varying level of thyrotropin (TSH and thyroid hormones. At follow-up after treatment, the patient continued with hyperthyroidism due to Graves’ disease. Autoimmune thyroiditis is a common complication of using interferon in patients with hepatitis C. In some cases, it is presented as hyperthyroidism because of Graves’ disease. Thyroid function and thyroid antibodies should be evaluated before and during treatment with interferon.

  17. Papel de la proteína supresora de la señalización por citocinas-3 (SOCS 3 en la resistencia a la hormona de crecimiento inducida por malnutrición.

    Directory of Open Access Journals (Sweden)

    Adriana Umaña

    2003-09-01

    Full Text Available La nutrición es un regulador importante de las acciones de la hormona de crecimiento (GH. Se ha demostrado que el déficit de nutrientes induce un estado de resistencia a la hormona, en el cual están involucrados, entre otros factores, alteraciones post-receptor en la vía de señalización, pero se desconocen los mecanismos responsables. En este trabajo se investigó la participación de algunos miembros de la familia de proteínas supresoras de la señalización por citocinas (SOCS en la resistencia causada por malnutrición, que inhibe la activación de la señalización a través de Janus cinasa 2/transductor de señal y activador de la transcripción 5 (JK2/STAT5. Se estudiaron los cambios en la expresión génica del receptor de GH (RGH, IGF-I y SOCS3 en el hígado de ratas alimentadas con una dieta baja en proteína (8% y estimuladas con GH. La restricción en el consumo de proteína disminuyó significativamente (p

  18. Hydrogen sulfide corrosion of weld regions in API X52 steel; Corrosion por acido sulfhidrico de las regiones de soldadura en acero API X52

    Energy Technology Data Exchange (ETDEWEB)

    Arenas-Martinez, L.F [Universidad Autonoma de Coahuila, Coahuila (Mexico)]. E-mail: fernando.arenas@uadec.edu.mx; Garcia-Cerecero, G. [Corporacion Mexicana de Investigacion en Materiales S.A. de C.V., Saltillo, Coahuila (Mexico)

    2012-10-15

    The corrosion behavior of gas metal arc welding (GMAW) regions has been studied using potentiodynamic polarization and polarization resistance (LPR) techniques. Experiments were conducted in hydrogen sulfide (H{sub 2}S)-containing brine and in H{sub 2}S-free brine. Welds were made on API 5L X52 steel. Due to differences in their microstructure, chemical composition and residual stress level, weld regions exhibited different responses under H{sub 2}S corrosion. Base metal exhibited the highest corrosion rate (CR) and the most cathodic corrosion potential. [Spanish] Se estudio el comportamiento ante la corrosion de las regiones de soldadura de un cordon realizado por arco metalico con gas (GMAW) sobre un acero grado API X52 mediante las tecnicas de polarizacion potencio dinamica y resistencia a la polarizacion (LPR). Los experimentos se realizaron utilizando salmuera con 300 ppm de acido sulfhidrico (H{sub 2}S) y salmuera libre de H{sub 2}S como electrolitos. Debido a las diferencias en su microestructura, composicion quimica y el nivel de esfuerzos residuales, las regiones de soldadura mostraron diferentes respuestas a la corrosion por H{sub 2}S. El metal base exhibio la velocidad de corrosion (VC) mas alta y el potencial de corrosion mas catodico.

  19. Cuidando de paciente com câncer de mama e osteonecrose mandibular induzida por bisfostonato: relato de experiência Cuidando de pacientes con cáncer de mama y osteonecrosis mandibular inducida por bisfosfonatos: relato de experiencia Providing care for patients with breast cancer and mandible ostheonecrosis induced by bisphosphonates: an experience report

    Directory of Open Access Journals (Sweden)

    Verônica Paula Torel de Moura

    2009-02-01

    Full Text Available OBJETIVO: Descrever as ações desenvolvidas pela enfermeira junto a uma paciente com câncer de mama e metástase óssea que apresentou necrose mandibular induzida pelo uso de bisfosfonato. RESULTADOS: As intervenções de enfermagem incluíram o ensino e reforço das orientações sobre higiene oral, destacando a escovação adequada, bochechos com solução antisséptica sem álcool, bem como sobre o controle da dor. CONCLUSÃO: Destaca-se a importância da atuação multiprofissional e da consulta de enfermagem no seguimento dessas pacientes para detecção precoce e controle dessa complicação.OBJETIVO: Describir las acciones de enfermería implementadas por la enfermera a una paciente con cáncer con metástasis ósea que presentó necrosis mandibular inducida por el uso de bisfosfonatos. RESULTADOS: Las intervenciones de enfermería incluyeron la enseñanza y el refuerzo de las orientaciones sobre la higiene oral, dando destaque al adecuado cepillado de los dientes, gárgaras con solución antiséptica sin alcohol y al control del dolor. CONCLUSIÓN: Es destacada el importancia de la actuación multiprofesional y de la consulta de enfermería en el seguimiento de esas pacientes, visando la detección temprana y el control de esa complicación.OBJECTIVE: To describe a nurse experience in providing care for a patient with cancer of the breast and bone metastasis who presented mandibular ostheonecrosis induced by the use of bisphosphonates. RESULTS: Nursing interventions included the re-enforcement of the guidelines for oral hygiene, highlighting the appropriate teeth-brushing technique, gargling with antiseptic solution without alcohol, as approach to pain management. CONCLUSION: There is a need for multidisciplinary and nursing consultations for early detection and control of potential complications.

  20. Corrosion

    Science.gov (United States)

    Slabaugh, W. H.

    1974-01-01

    Presents some materials for use in demonstration and experimentation of corrosion processes, including corrosion stimulation and inhibition. Indicates that basic concepts of electrochemistry, crystal structure, and kinetics can be extended to practical chemistry through corrosion explanation. (CC)

  1. Protection against corrosion to high temperature by means of rich silicon coatings; Proteccion contra corrosion a alta temperatura por medio de recubrimientos ricos en silicio

    Energy Technology Data Exchange (ETDEWEB)

    Porcayo Calderon, Jesus [Instituto de Investigaciones Electricas, Temixco, Morelos (Mexico)

    1999-07-01

    In this research work the study of the process of corrosion by molten salts of sodium sulphate-vanadium pentoxide and its prevention by means of metallic coatings rich in silicon was contemplated. The research encompassed the development of the coating system, the chemical and thermochemical analysis of the system sodium sulphate - vanadium pentoxide, the evaluation of the resistance to the corrosion of the coating system by gravimetric and electrochemistry techniques, and the study of the stability of the coating system - substrate. [Spanish] En este trabajo de investigacion se contempla el estudio del proceso de corrosion por sales fundidas de sulfato de sodio - pentoxido de vanadio y su prevencion por medio de recubrimientos metalicos ricos en silicio. La investigacion abarca el desarrollo del sistema de recubrimientos, el analisis quimico y termoquimico del sistema sulfato de sodio - pentoxido de vanadio, la evaluacion de la resistencia a la corrosion del sistema de recubrimientos por tecnicas gravimetricas y electroquimicas, y el estudio de la estabilidad del sistema recubrimiento - sustrato.

  2. Estudio del D-004 sobre la defensa antioxidante endógena en ratas con hiperplasia prostática inducida por inyección de testosterona Study of D-004 on the endogenous antioxidant defence in rats presenting with prostate hyperplasia induced by testosterone injection

    Directory of Open Access Journals (Sweden)

    Yohani Pérez Guerra

    2010-06-01

    Full Text Available La hiperplasia prostática benigna, enfermedad común en hombres mayores de 50 años de edad, se caracteriza por el crecimiento incontrolado de la glándula prostática y la presencia de síntomas del tracto bajo urinario. El estrés oxidativo ha sido recientemente asociado con la causa de esta enfermedad. El D-004, extracto lipídico del fruto de la Roystonea regia, ha mostrado reducir la hiperplasia prostática inducida por testosterona en roedores y producir efectos antioxidantes in vitro e in vivo, pero sus efectos sobre las enzimas del sistema antioxidante endógeno no han sido estudiados. Este trabajo investigó los efectos del tratamiento oral con D-004, durante 14 días, sobre las enzimas superóxido dismutasa y catalasa en ratas con hiperplasia prostática inducida por testosterona. Los animales se distribuyeron en 4 grupos: un control negativo y tres inyectados con testosterona: uno tratado con el vehículo (control positivo y dos con D-004 (400 y 800 mg/kg, respectivamente. Se determinó la capacidad antioxidante total del plasma y las actividades de las enzimas superóxido dismutasa y catalasa en eritocitos lisados y plasma, respectivamente. El tratamiento oral con D-004 (400 y 800 mg/kg previno de modo marcado y significativo el agrandamiento de la próstata inducido con testosterona en ratas, y aumentó significativamente la capacidad antioxidante del plasma y la actividad de la catalasa, sin modificar la actividad de la superóxido dismutasa. Estos resultados sugieren que la actividad antioxidante del D-004 está relacionada, al menos parcialmente, con la estimulación de algunas enzimas del sistema antioxidante endógeno.Benign prostatic hyperplasia, a common disease in men aged over 50 is characterized by uncontrolled growth of prostatic gland and the presence of low urinary tract symptoms. The oxidative stress has been recently associated with the disease cause. The D-004, a lipid extract from Roystonea regia, reduces the

  3. Há uma associação entre anti-inflamatórios não-esteroides e nefropatia induzida por contraste? ¿Hay una asociación entre antiinflamatorios no esteroides y nefropatía inducida por contraste? Is there an association between non-steroidal anti-inflammatory drugs and contrast nephropathy?

    Directory of Open Access Journals (Sweden)

    Luciano Passamani Diogo

    2010-12-01

    Full Text Available FUNDAMENTO: A associação entre o uso de anti-inflamatórios não-esteroides (AINEs e insuficiência renal aguda ou crônica é bem documentada, mas evidências sobre a associação entre AINEs e nefropatia induzida por contraste (NIC não são encontradas na literatura. OBJETIVO: Avaliar uma possível associação entre AINEs e NIC. MÉTODOS: Em um estudo de coorte, através da entrevista clínica de pacientes que foram submetidos à cateterização cardíaca, analisamos o uso de AINEs e sua associação com desenvolvimento de NIC, através da alteração dos níveis de creatinina sérica ou taxa de filtração glomerular em 48 ou 72 horas. RESULTADOS: No período de julho de 2005 a julho de 2006, 236 pacientes foram incluídos no estudo, dos quais 29 foram posteriormente excluídos. A incidência de NIC foi 10,37% (20 de 207 e 42% dos pacientes estavam recebendo AINEs até o momento da avaliação. Não houve associação entre o uso de AINEs e o desenvolvimento de NIC com OR de 1,293; IC95% (0,46-4,2. O estudo detectou fatores de risco conhecidos para o desenvolvimento de NIC, tais como diabete, com OR de 2,77; IC95% (1,05-7,47 e insuficiência renal crônica com OR de 3,48; IC95% (1,1-11,07 e também sugeriu uma ação protetora da hidratação com solução salina com OR de 0,166; IC95% (0,03-0,92. CONCLUSÃO: Com base nos dados obtidos, concluímos que não houve associação entre NIC e uso prévio de AINEs, pelo menos com um OR > 2,85, o qual nossa amostra detectou.FUNDAMENTO: La asociación entre el uso de antiinflamatorios no esteroides (AINEs e insuficiencia renal aguda o crónica está bien documentada, pero evidencias sobre la asociación entre AINEs y nefropatía inducida por contraste (NIC no son encontradas en la literatura. OBJETIVO: Evaluar una posible asociación entre AINEs y NIC. MÉTODOS: En un estudio de cohorte, a través de la entrevista clínica de pacientes que fueron sometidos a cateterismo cardíaco, analizamos el

  4. Análisis Ultraestructural del Efecto Neuroprotector de la Melatonina sobre las lesiones del Cortex Cerebeloso del Embrión de Pollo inducidas por Glutamato Monosódico.

    OpenAIRE

    García de la Oliva, Alejandro

    2017-01-01

    En el presente estudio analizamos el efecto neuroprotector que la administración exógena de la melatonina ejerce sobre las lesiones neurodegenerativas de la corteza cerebelosa del embrión de pollo causadas por excitotoxicidad glutamatérgica. Para ello hemos diseñado un modelo experimental que nos permite: por un lado, evaluar y seguir la evolución de las lesiones que sobre el desarrollo de la corteza cerebelosa produce la administración de gl...

  5. Estimulación de la actividad péptica del jugo gástrico, inducida por látex de Croton palanostigma (sangre de grado

    Directory of Open Access Journals (Sweden)

    Miguel Sanvodal

    2008-09-01

    Full Text Available Objetivo: Determinar si la administración del látex de Croton palanostigma (sangre de grado, vía digestiva, modifica la actividad péptica de la secreción gástrica. Diseño: Estudio experimental. Institución: Centro de Investigación de Bioquímica y Nutrición Alberto Guzmán Barrón, Facultad de Medicina, Universidad Nacional Mayor de San Marcos. Material biológico: Ratas albinas machos adultos y sangre de grado. Métodos: Se usó 50 ratas albinas machos adultos, entre 200 y 250 g de peso, que fueron distribuidas aleatoriamente en 5 grupos, a los que se administró por vía oro-gástrica, y en dosis única, como sigue: grupo I: 0,8 mL/kg de sangre de grado; grupo II: 0,8 mL/kg de sangre de grado neutralizada; grupo III: ranitidina 50 mg/kg; grupo IV: control, con solución salina 0,9 g% (sin histamina; grupo V: control con solución salina 0,9 g%. Se realizó ligadura pilórica, por laparotomía, con anestesia de éter etílico. Se utilizó histamina, aplicada por vía subcutánea, para estimular la secreción, excepto al grupo IV. Cuatro horas después, se extrajo el jugo gástrico, se midió el volumen, el pH por potenciometría y la actividad de la pepsina, por el método de Anson modificado, expresado como µg de tirosina/mL. Principales medidas de resultados: Modificación de la actividad péptica de la secreción gástrica. Resultados: El volumen del jugo gástrico fue significativamente menor en los grupos II y III; que en los otros, entre los que no hubo diferencia estadística. El pH del grupo III (con ranitidina fue significativamente mayor que los otros, demostrando el efecto del fármaco. La actividad péptica fue: con sangre de grado 5,34+1,04; sangre de grado neutralizada 2,69+1,27; grupo ranitidina 2,57+0,88; el control sin histamina 3,29+0,94 y control con histamina 3,58+1,18. La actividad péptica fue significativamente mayor (+49,2% en el grupo con sangre de grado (p<0,01 que en los otros grupos. Conclusiones

  6. Estudio de las alteraciones metabólicas inducidas por la dieta mediante técnicas de proteómica. Efecto del consumo de ácidos grasos omega-3 de origen marino

    OpenAIRE

    Méndez López, Lucía

    2016-01-01

    Las enfermedades cardiovasculares y la diabetes tipo 2 se han convertido en el principal problema de salud de los países desarrollados como consecuencia del consumo de dietas hipercalóricas y un estilo de vida sedentario. Estos problemas de salud están frecuentemente precedidos por el desarrollo de un grupo de alteraciones metabólicas que incluyen obesidad, resistencia a insulina, tolerancia a la glucosa deteriorada, dislipidemia e hipertensión, las cuales están interconectadas y caracterizan...

  7. 57. El menor número de células progenitoras endoteliales en la sangre periférica de pacientes coronarios no está relacionado con una disfunción in vitro inducida por su plasma

    Directory of Open Access Journals (Sweden)

    A. González Rocafort

    2010-01-01

    Conclusiones: Los pacientes coronarios tienen un menor nivel preoperatorio de EPC que los valvulares. La disfunción en cultivo de las EPC de pacientes ateroscleróticos no se observa en EPC cultivadas obtenidas de donantes sanos tras la incubación con plasma de pacientes coronarios, y, por lo tanto, podría ser debida más a factores intrínsecos de estas células en su procedencia de la médula ósea que a factores del medio.

  8. Prevention, Diagnosis and Treatment of Chemotherapy-Induced Cardiotoxicity: what Are we Doing about it? Prevención, diagnóstico y tratamiento de la cardiotoxicidad inducida por quimioterapia: ¿qué estamos haciendo?

    Directory of Open Access Journals (Sweden)

    Lázaro de la Cruz Avilés

    2012-11-01

    Full Text Available Heart disease and malignant tumors are the two leading causes of death in Cuba, with mortality rates of 197,5 and 193,6 per 100 000, respectively, in 2011. In Cienfuegos, malignant tumors were the leading cause of death with a rate of 115,2 followed by heart disease with 102,6 per 100 000 inhabitants. The improvements in the detection and treatment of cancer have led to a new cohort of patients achieving such a long survival that cardiac complications may appear. Unfortunately, the wide knowledge on biochemical pathways involved in cancer targeted therapy has not been accompanied by a parallel understanding of cardiac consequences of their modulation.Las enfermedades del corazón y los tumores malignos constituyen las dos primeras causas de muerte en Cuba, con tasas de mortalidad de 197,5 y 193,6 por 100 000 habitantes, respectivamente, en el año 2011. En Cienfuegos los tumores malignos fueron la primera causa de muerte con una tasa de 115,2 seguida de las enfermedades del corazón con 102,6 por 100 000 habitantes. Las mejoras alcanzadas en la detección y el tratamiento del cáncer han dado origen a una nueva cohorte de pacientes que alcanzan una supervivencia suficiente para que puedan aparecer complicaciones cardíacas derivadas del tratamiento. Lamentablemente, el abundante conocimiento sobre las vías bioquímicas involucradas en el tratamiento dirigido del cáncer no se ha visto acompañado de un conocimiento paralelo de las consecuencias cardíacas de su modulación.

  9. Rutas de señalización celular involucradas en la plasticidad post-sináptica inducida por la activación de los canales de glutamato tipo NMDA en el hipocampo

    Directory of Open Access Journals (Sweden)

    Sebastián Patrón Saade

    2005-01-01

    Full Text Available La apertura de los canales de glutamato tipo NMDA, gracias a la acción concomitante de las neuronas pre-sináptica y post-sináptica a nivel de las espinas dendríticas, induce a modificaciones de la fuerza y eficacia sinápticas en éstas, fenómeno mejor conocido como plasticidad sináptica. Las dos formas conocidas de plasticidad sinápticas son la potenciación a largo plazo (LTP y la depresión a largo plazo (LTD. Subyacen a ambos tipos de plasticidad modificaciones covalentes sobre las distintas proteínas que componen la densidad post-sináptica y, en caso de que la LTP se prolongue, una regulación activa de la transcripción y traducción de material genético. Así, la regulación activa de la fuerza y eficacia sináptica se debe al control activo sobre la tasa de inserción y remoción de los receptores de glutamato tipo AMPA, receptores encargados de la excitación rápida en el cerebro. Lo significativo de dicho evento en el hipocampo se debe a que éste está relacionado de manera estrecha con la memoria declarativa de los individuos, su memoria de reconocimiento y la memoria espacial, esta última mediada por la activación precisa y coordinada de las células de lugar que se encuentran en él.

  10. Evolución de la precipitación inducida por la deformación en aceros microaleados con Nb y V, e influencia sobre las propiedades mecánicas

    Directory of Open Access Journals (Sweden)

    Quispe, A.

    2004-04-01

    Full Text Available By means of hot torsion tests and applying the “Back Extrapolation” method, the static recrystallization kinetics in V and Nb-microalloyed steels has been determined and the recrystallization-precipitation-time-temperature (RPTT diagrams have also been plotted. The RPTT diagrams graphically show the Recristalization-Precipitation interaction and simultaneously the determination of the static recrystallization critical temperature (SRCT. The mentioned temperature represents the limit between the two phases, before and after of the precipitation. The activation energy for static recrytallization of the austenite before and after precipitation has also been determined. The present study is completed with the determination of the precipitate size distribution diagrams by means of TEM analysis.

    Mediante ensayos de torsión y haciendo uso del método conocido como “Back Extrapolation” se ha determinado la cinética de recristalización estática de dos aceros microaleados con V y Nb, respectivamente, y a partir de las mismas ha sido posible dibujar los diagramas recristalización-precipitación-tiempo-temperatura (RPTT. Los diagramas RPTT muestran gráficamente la interacción Recristalización- Precipitación y simultáneamente permiten la determinación de la Temperatura Crítica de Recristalización Estática (SRCT. Dicha temperatura crítica representa el límite entre las dos fases, antes y después de la precipitación. También se ha determinado la energía de activación de la recristalización estática de la austenita antes y después de la precipitación. El presente estudio es completado con la determinación de los diagramas de distribución del tamaño de los precipitados a través del análisis por TEM.

  11. Resistance exercise-induced microinjuries do not depend on 1or 3 minutes rest time interval between series. (Las microlesiones inducidas por el entrenamiento con cargas no dependen de los intervalos de descanso entre series de 1 o 3 minutos.

    Directory of Open Access Journals (Sweden)

    Rafael Pereira

    2008-10-01

    Full Text Available AbstractIn order to examine the effects of different rest intervals between sets on the muscle fiber integrity, 14 male subjects volunteered to participate in randomized crossover design methodology. All subjects completed 2 experimental training sessions. Both sessions consisted of 3 sets of 10 repetitions with 10 repetition maximum resistance bench press, cable pulldowns, military press, biceps curl, triceps curl, leg press, leg extension, and lying leg curls. The 2 experimental sessions differed only in the length of the rest period between sets and exercises: 1 session with a 1-minute and the other with a 3-minute rest period. the mechanical stress caused by the proposed training session cause similar damage in the muscle fibers do not depend of the 1 or 3 minutes of rest interval between series. ResumenEl propósito de ese estudio fue comparar los efectos de 2 diferentes períodos de descanso durante una sesión de entrenamiento con cargas en la integridad de la fibra muscular. Participaron de forma voluntaria 14 hombres en un estudio con diseño cruzado aleatorio. Todos los sujetos realizaron 2 sesiones de entrenamiento con cargas. Durante cada sesión, los sujetos completaban 3 series de 10 repeticiones máximas de press de banca, jalón en polea alta para dorsal, press militar, curl de bíceps con barra, extensión de tríceps trasnuca con mancuerna, prensa de piernas en máquina, extensión de rodillas en máquina, y flexión de rodillas en máquina. Las 2 sesiones experimentales diferían sólo en la longitud del período de descanso entre las series y los ejercicios: una sesión con 1 minuto y la otra con 3 minutos en los períodos de descanso. La tensión mecánica causada por las sesiones puede causar daños similares en las fibras musculares y no dependen de hacer 1 o 3 minutos de intervalo de descanso entre las series.

  12. Meteorites as space probes for cosmic rays; Les meteorites en tant que sondes spatiales pour les rayons cosmiques; Meteority v kachestve prob mezhplanetnogo prostranstva dlya izucheniya kosmicheskikh luchej; Los meteoritos como sondas espaciales para evaluar la actividad inducida por los rayos cosmicos

    Energy Technology Data Exchange (ETDEWEB)

    Schaeffer, O A; Stoenner, R W; Davis, R Jr [Chemistry Department, Brookhaven National Laboratory, Upton, L. I., NY (United States)

    1962-01-15

    'activite imputable a l'argon-37 (periode: 35 jours) et a l'argon-39 (periode: 325 ans). Ils comparent ces activites relatives aux taux de production de ces isotopes que l'on obtient en bombardant un echantillon de la meteorite avec des protons ayant une energie de 3 GeV. Les auteurs concluent que, dans les limites d'erreur, le flux de rayons cosmiques est le meme dans la ceinture asteroide que dans le voisinage de l'orbite terrestre. (author) [Spanish] Para determinar la constancia espacial de la radiacion cosmica de elevada energia en el interior del sistema solar, los autores midieron la radiactividad, inducida por los rayos cosmicos, de un elemento de periodo corto y de un elemento de periodo largo en un meteorito caido recientemente. El experimento se basa en el hecho de que los meteoritos siguen orbitas muy excetricas y, por ello, pueden ser utilizados como sondas espaciales en la region situada entre la orbita terrestre y el cinturon de asteroides. La actividad de periodo corto se produce mientras el meteorito se encuentra en las proximidades de la orbita terrestre, en tanto que la actividad de periodo largo es inducida en toda la orbita descrita por el meteorito. Los autores efectuaron las mediciones en el condrito Hamlet que cayo en Indiana el 13 de octubre de 1.959. Evaluaron las actividades astribuibles al argon-37 (periodo: 35 dias) y al argon-39 (periodo: 325 anos). Compararon los valores relativos de estas actividades con los indices de produccion de esos isotopos que se alcanzan bombardeando una muestra del meteorito con protones de 3 GeV. Se llega a la conclusion de que la intensidad de la radiacion cosmica es igual, dentro de los limites de error, en el cinturon de asteroides que en las proximidades de la orbita terrestre. (author) [Russian] Byl proizveden opyt ispytaniya prostranstvennogo postoyanstva kosmicheskogo izlucheniya vysokikh ehnergij v solnechnoj sisteme putem zamera iskusstvennoj korotkozhivushchej i dol- gozhivushchej radioaktivnosti kosmicheskikh

  13. Exercício físico previne alterações cardiometabólicas induzidas pelo uso crônico de glicocorticóides Ejercicio físico previene alteraciones cardiometabólicas inducidas por el uso crónico de glucocorticoides Exercise prevents cardiometabolic alterations induced by chronic use of glucocorticoids

    Directory of Open Access Journals (Sweden)

    Carlos Hermano da Justa Pinheiro

    2009-10-01

    , diabetes, dislipidemia, esteatosis hepática e hipertensión arterial. OBJETIVOS: Evaluar el efecto de la práctica regular de ejercicio físico aeróbico sobre las alteraciones cardiometabólicas inducidas por administración crónica de dexametasona (Dex - 0,5 mg/kg/día i.p en ratones. MÉTODOS: Se dividieron ratones Wistar machos (n = 24 en cuatro grupos: Grupo control; Grupo entrenado; Grupo tratado con Dex y Grupo tratado con Dex y entrenado. El entrenamiento físico (iniciado 72 horas después de la primera dosis de Dex se realizó 3 veces por semana, hasta el final del tratamiento. Al final de ese período, se realizaron las siguientes evaluaciones bioquímicas: glicemia en ayunas, test de tolerancia a la glucosa y análisis del perfil lipídico en sangre que incluyó colesterol total (CT, LDL-c, HDL-c, VLDL-c y triglicéridos (TG. También se evaluaron, el peso del músculo gastrocnemio, análisis histopatológico del hígado y los índices cardiometabólicos (CT/HDL-c, LDL-c/HDL-c y TG/HDL-c. RESULTADOS: Se observó hiperglicemia, menor tolerancia a la glucosa, elevación de CT, LDL-c, VLDL-c y TG, disminución del HDL-c, presencia de esteatosis hepática, hipotrofia muscular y elevación de los índices CT/HDL-c, LDL-c/HDL-c y TG/HDL-c en los animales tratados con Dex. El ejercicio físico redujo la hiperglicemia, mejoró la tolerancia a la glucosa, redujo la dislipidemia y previno la esteatosis hepática, la hipotrofia muscular y redujo los índices CT/HDL-c, LDL-c/ HDL-c ye TG/HDL-c. Con todo, no hubo efecto significativo del entrenamiento físico sobre el HDL-c. CONCLUSIÓN: El ejercicio físico aeróbico tiene efecto protector con las alteraciones cardiometabólicas inducidas por el uso crónico de glucocorticoides.BACKGROUND: Chronically, glucocorticoids induce adverse cardiometabolic alterations including insulin resistance, diabetes, dyslipidemia, liver steatosis and arterial hypertension. OBJECTIVES: To evaluate the effect of regular practice of aerobic

  14. MODELO EXPERIMENTAL DE GLOMERULONEFRITIS MEMBRANOSA INDUCIDA CON ALBUMINA BOVINA

    Directory of Open Access Journals (Sweden)

    Fontenla M

    2013-07-01

    Full Text Available El objetivo del presente trabajo fue diseñar un modelo experimental de Glomerulonefritis Membranosa (GM en ratas Wistar, inducida con Seroalbúmina Bovina (BSA, y validarlo mediante la determinación de parámetros bioquímicos, histológicos, ultraestructurales y detección de inmunocomplejos por inmunofluorescencia (IF. Los animales del grupo experimental fueron inmunizados por vía subcutánea, con dosis de 3 mg c/u de BSA/PBS con adyuvante de Freund. Se efectuaron diferentes esquemas de inmunización. Cuando el título de anticuerpos fue ≥1/2, comenzó la administración diaria de 2 mg, por vía endovenosa de BSA/PBS, durante 15 días. Se evaluó la funcionalidad renal por la proteinuria; después de la 5° semana, desde su aparición, se determinó: depuración (clearance de creatinina, uremia, proteinemia y perfil lipídico. Los dos riñones se usaron para estudios histológicos, ultraestructurales y detección de inmunocomplejos por IF. Los resultados mostraron que la inmunización fue efectiva con 5 R E S U M E N inoculaciones c/15 días. En los animales nefróticos la proteinuria, depuración (clearance de creatinina, proteinemia , uremia y el perfil lipídico presentaron alteraciones significativas (p<0.0001. Al microscopio óptico se observó hipercelularidad, engrosamiento difuso de las membranas basales de los capilares glomerulares y diferentes grados de atrofia, esclerosis e hialinización de los glomérulos. Por IF se detectó inmunocomplejos IgG en el 100 % de los glomérulos. Ultraestructuralmente, se observaron depósitos subepiteliales electrodensos en la membrana basal engrosada, compatibles con inmunocomplejos . Se encontraron alteraciones en la estructura de los podocitos. En conclusión, los estudios bioquímicos, estructurales y ultraestructurales permitieron inferir la inducción de un síndrome nefrótico experimental. Concluimos que el protocolo utilizado tiene validez para la inducción de una glomerulonefritis

  15. Copolymerization of Ethylene Induced by Cobalt-60 Gamma Radiation; Copolymerisation de l'ethylene induite par des rayons gamma du cobalt-60; Sopolimerizatsiya ehtilena pod dejstviem gamma-izlucheniya ot istochnika ks'yali-60; Copolimerizacion del etileno inducida por las radiaciones gamma del cobalto-60

    Energy Technology Data Exchange (ETDEWEB)

    Steinberg, M.; Colombo, P. [Brookhaven National Laboratory, Long Island, NY (United States)

    1963-11-15

    }C et a des pressions initiales allant jusqu'a 680 atm. On a procede aux experiences, en milieu statique, dans des systemes a deux phases, a l'exception du systeme ethylene-oxyde de carbone. La separation des copolymeres a ete obtenue par des methodes d'extraction par solvant et de precipitation fractionnee. L'identification a ete faite au moyen de la spectroscopic aux infrarouges. La composition a ete determinee par analyse elementaire. Les auteurs donnent une evaluation partielle de certains produits de la reaction, y compris les points de fusion cristalline, les densites, les caracteristiques de solubilite et les poids moleculaires. La copolymerisation de l'ethylene a ete etablie avec chacun des monomeres suivants : styrene, methacrylate de methyle, acetate de vinyle, acrylonitrile, acetate d'allyle, isobutylene, chlorotiifluoroethylene, transbutene-2, acrylate de methyle, isoprene, propylene, chlorure de vinyle, butene-1, cis-butene-2, oxyde de carbone, pyrrolidone de vinyle, methyle- vinyle-cetone et divinyle-benzene. Les auteurs ont trouve que les donnees experimentales obtenues dans l'etude du systeme ethylene-oxyde de carbone suivaient une forme lineaire de l'equation de composition du copolymere. Pour le rapport {alpha} des constantes de vitesse specifiques de l'oxyde de carbone et de l'ethylene, ils ont determine la valeur 22,0, ce qui montre que l'oxyde de carbone en tant que monomere est active a tel point qu'il se fixe a l'extremite d'une chaftie de radicaux libres d'ethylene 22 fois plus vite que ne le fait un monomere d'ethylene. (author) [Spanish] Los autores estudiaron la copolimerizacion del etileno, inducida por las radiaciones gamma, con una serie de diversos monometos, a 20{sup o}C y presiones iniciales de hasta 680 atm. Los experimentos se llevaron a cabo estaticamente en sistemas bifasicos, salvo en el caso del etileno-oxido de carbono. La separacion de los copolimeros se llevo a cabo por extraccion mediante disolventes y por precipitacion

  16. Alterações em variáveis motoras e metabólicas induzidas pelo treinamento durante um macrociclo em jogadores de handebol Alteraciones en las variables motoras y metabólicas inducidas por el entrenamiento durante un macro ciclo en jugadores de balonmano Changes in metabolic and motor performance variables induced by training in handball players

    Directory of Open Access Journals (Sweden)

    Juvenilson de Souza

    2006-06-01

    Full Text Available A monitoração do treinamento é uma prática comum no desporto. Essa monitoração deve ser baseada em testes específicos e que reflitam as adaptações às diversas etapas de treinamento, permitindo, assim, ajustes no programa deste. Assim, este estudo teve como objetivo analisar as alterações em variáveis motoras e metabólicas induzidas pelo treinamento durante um macrociclo em jogadores de handebol. Os atletas foram submetidos a um programa de preparação fundamentado no modelo de periodização proposto por Verkhoshanski(7 e adaptado por Oliveira(8. Foram estudados 11 jogadores de handebol, que realizaram treinamentos diários, na faixa etária de 20 a 32 anos, massa corporal média de 89,5 ± 10,4kg (70,2 a 105,1kg, e estatura média de 184,4 ± 6,7cm (171,8 a 198cm, filiados à equipe "UniFil/Londrina" do município de Londrina - PR. Os handebolistas foram submetidos a duas baterias de testes: a primeira no início do segundo macrociclo de treinamento e a segunda após 16 semanas, antecedendo o início da liga nacional. Para análise dos dados foi utilizado teste t para medidas repetidas com p La monitorización del entrenamiento es una práctica común en el deporte. Esa monitorización debe basarse en pruebas específicas y que reflejen las adaptaciones a las diversas etapas del entrenamiento, permitiendo así, ajustes en el programa del mismo. Así, este estudio ha tenido como objetivo analizar las alteraciones en las variables motoras y metabólicas inducidas por el entrenamiento durante un macro ciclo en jugadores de balonmano. Los atletas fueron sometidos a un programa de preparación basado en el modelo de periodicidad propuesto por Verkhoshanski(7 y adaptado por Oliveira(8. Fueron estudiados 11 jugadores de balonmano que realizaron entrenamiento diario, con edades entre 20 y 32 años, masa corporal media de 89,5 ± 10,4 kg (70,2 y 105,1 kg, y estatura media de 184,4 ± 6,7 cm (171,8 y 198 cm, afiliados al equipo "Uni

  17. Methodology for the accelerated simulation of the deterioration that by atmospheric corrosion appears in electronic equipment; Metodologia para la simulacion acelerada del deterioro que por corrosion atmosferica se presenta en equipo electronico

    Energy Technology Data Exchange (ETDEWEB)

    Ortiz Prado, A.; Schouwenaars, R.; Cerrud Sanchez, S.M. [Facultad de Ingenieria, UNAM, Mexico, D.F. (Mexico)

    2002-12-01

    The corrosion resistance of systems and electronic parts which are designed to work in atmospheric conditions have been tested for decades; some of these methods were the Cyclic Humidity Test, Field Tests and Salt Spray (Fog) Testing, the latter was one of the most popular methods. However, the salt spray test and most of the other existing methods do not show strong relationships with the real conditions of service. For this reason, it is necessary to develop appropriated methods and equipment for the accelerated simulation of real atmospheric corrosion phenomena. This article seeks to demonstrate the need to develop a test and the necessary equipment to reproduce the damage in electronic systems and equipment by atmospheric corrosion. [Spanish] Para la evaluacion de la resistencia a la corrosion de sistemas y equipo electronico que trabajaran bajo condiciones de deterioro generadas por el medio ambiente, se han aplicado una serie de ensayos, donde el mas popular es el de camara de niebla salina. Sin embargo, este y otros que se han elaborado para tal efecto no tienen ninguna relacion con las condiciones reales de servicio, por lo que es necesario un metodo de evaluacion que permita simular de forma acelerada los fenomenos de deterioro por efectos ambientales. Este articulo pretende demostrar la necesidad de desarrollar una prueba, que en forma acelerada, reproduzca el dano que sufre el material por efecto de la atmosfera; el cual se orienta a la evaluacion de equipo electrico y electronico.

  18. Alteração da relação testosterona: cortisol induzida pelo treinamento de força em mulheres Alteración de la relación testosterona: cortisol inducida por el entrenamiento de fuerza en mujeres Alteration of testosterone: cortisol ratio induced by resistance training in women

    Directory of Open Access Journals (Sweden)

    Marco Carlos Uchida

    2004-06-01

    Full Text Available A razão entre a concentração de testosterona e cortisol (T:C é freqüentemente utilizada como indicativo do nível de estresse imposto pelo exercício. Alterações na concentração destes hormônios são responsáveis por modular diversas respostas induzidas pelo treinamento, como hipertrofia e ganho de força. O objetivo do presente estudo foi examinar a influência do protocolo de treinamento de força, conhecido como múltiplas-séries (MS, sobre o ganho de força, de resistência muscular localizada e a relação entre a concentração de hormônios catabólicos (cortisol e anabólicos (testosterona. Para testar esta hipótese cinco jovens do sexo feminino com um ano de experiência em treinamento de força foram submetidas ao protocolo MS. As amostras de sangue foram coletadas antes e imediatamente após o exercício, no primeiro dia e após oito semanas de treinamento. Os testes de 1-RM e de repetições máximas foram realizados também no início e ao final das oito semanas de treinamento de força. Não foram observadas alterações na massa corporal, no IMC, na percentagem de massa gorda e na força máxima (1-RM no supino, no agachamento e na rosca direta. O número de repetições máximas a 50% de 1-RM foi aumentado apenas para o supino (p La razón entre testosterona y cortisol (T:C es frecuentemente utilizada como indicador del nivel de stress impuesto por el ejercicio. Las alteraciones de las concentraciones de estas hormonas son las responsables por modular diversas respuestas inducidas por el entrenamiento, como son la hipertrofia y el aumento de la fuerza. El objetivo del presente estudio fué examinar la influencia del protocolo de entrenamiento de fuerza, conocido como series multiples (MS, sobre la ganancia de fuerza, la resistencia muscular localizada y la relación entre las concentraciones de las hormonas catabólicas (cortisol y anabólicas (testoterona. Para testar esta hipótesis, cinco jovenes del sexo feminino

  19. Basic aspects of the carbon dioxide corrosion in oil and gas production; Aspectos basicos de la corrosion por dioxido de carbono en la produccion de petroleo y gas

    Energy Technology Data Exchange (ETDEWEB)

    Angulo Macias, J.

    2010-07-01

    Carbon dioxide (CO{sub 2}) is a non-corrosive gas within the driven conditions in the oil and gas industry, but the presence of water converts it, maybe, in the most important component in the corrosive processes in this industry. Corrosion has an important impact inside the oil and gas companies, no only in economics but also in safety, environmental and social aspects. After several decades of investigation of these corrosion processes, there are still several mechanisms not fully understood. (Author) 19 refs.

  20. EVALUACION DE LA RESISTENCIA A LA CORROSION DEL SISTEMA PRIMER EPOXICO RICO EN ZINC/ACABADO POLISILOXANO POR MEDIO DE ESPECTROSCOPIA DE IMPEDANCIA ELECTROQUIMICA

    Directory of Open Access Journals (Sweden)

    ANDRES ALBERTO GUZMAN ROSAS

    2011-01-01

    Full Text Available En este trabajo fue estudiado el sistema primer epoxico rico en zinc / acabado polisiloxano aplicado sobre laminas de acero al carbono laminado en caliente y sometido a camaras de corrosion acelerada (inmersion total, niebla salina, ciclo de corrosion y prohesion por un periodo de hasta 5000 horas. Las probetas bajo estudio se evaluaron cada 20 dias por medio de espectroscopia de impedancia electroquimica y al final de la prueba se realizaron chequeos visuales y microscopia optica para ver la morfologia de la interface metal-recubrimiento y microespectroscopia Raman para identificar la presencia de posibles productos de corrosion. Los resultados de impedancia fueron simulados por medio de circuitos electricos equivalentes. Para el sistema se encontraron modulos de impedancia del orden de 1011 ¿.cm2 en prohesion, 1010 ¿.cm2 en ciclo de corrosion, 109 ¿.cm2 tanto niebla salina como en las inmersiones totales (NaCl 10-2M y Na2SO4 10-2M. Este sistema tuvo durante el tiempo de pruebas un comportamiento excelente con altas resistencias de pelicula y de transferencia de carga y bajas capacitancias de pelicula y de doble capa.

  1. Reação cutânea grave induzida por carbamazepina no tratamento da neuralgia pós-herpética: relato de caso Reacción cutánea grave inducida por la carbamazepina en el tratamiento de la neuralgia postherpética: relato de caso Severe carbamazepine-induced cutaneous reaction in the treatment of post-herpetic neuralgia: case report

    Directory of Open Access Journals (Sweden)

    João Batista Santos Garcia

    2010-08-01

    da carbamazepina, que deve sempre ser supervisionado, especialmente em idosos.JUSTIFICATIVA Y OBJETIVOS: El herpes zoster tiene como principal complicación la neuralgia postherpética (NPH. Para su tratamiento se usa la carbamazepina (CBZ, un anticonvulsivo bien tolerado, pero que sin embargo está a menudo asociado a reacciones cutáneas graves, como por ejemplo, el síndrome de Stevens-Johnson (SSJ y la necrólisis epidérmica tóxica (NET. El objetivo de este trabajo es relatar un caso de SSJ/NET secundario al uso de CBZ en paciente con NPH. RELATO DEL CASO: Paciente del sexo femenino, con dolor continuo e intenso en la región torácica y dorso, ardor, punzada, descarga eléctrica, alteración de fuerza del miembro superior ipsilateral y sudoración. Presentaba lesiones de postillas y eritemas en la región dorsal del tórax, con alodinia y disestesias en el dermatoma acometido. Se inició CBZ 300 mg.día-1, amitriptilina (AMT12,5 mg por la noche e infiltración con anestésico local en la región afectada. Después de 15 días, el paciente decía sentir un fuerte malestar, fiebre, dolores musculares y artralgias con rash cutáneo ligero e inespecífico. Se le retiró la carbamazepina inmediatamente. Una semana después fue ingresado con urticaria y exantema generalizados, erupciones cutáneas eritematosas, burbujas y marcas purpúricas por todo el cuerpo. La impresión era de SSJ/NET inducida por carbamazepina. Hubo un progresivo empeoramiento del cuadro, con aumento del número y del tamaño de las lesiones cutáneas, además de rash eritematoso macular generalizado, áreas de necrosis y erosiones simétricas de la epidermis en la cara, cuello, tórax, dorso y miembros, llegando a más del 50% del área de superficie, además de la involucración de la mucosa bucal, conjuntival y genital con erosiones vesiculares. Presentó un empeoramiento funcional progresivo, evolucionando con choque séptico y fracaso multiorgánico, lo que produjo finalmente su deceso

  2. Desarrollo de métodos para la evaluación integrada de propiedades mecánicas y superficiales inducidas en materiales metálicos mediante tratamiento superficial por ondas de choque generadas por láser

    OpenAIRE

    Ruiz de Lara de Luis, Leonardo

    2016-01-01

    El tratamiento superficial por ondas de choque generadas por láser, LSP, es una técnica cuyo principal objetivo es el de la modificación del estado tensional de las primeras micras en profundidad de materiales metálicos. En sus comienzos está técnica fue empleada para inducir tensiones residuales de compresión en superficie, pero mientras se avanzaba en su desarrollo se empezaron a observar otros efectos. Profundizando en ellos se llega a la conclusión de que existe una fuerte relación entre ...

  3. Applied methods for mitigation of damage by stress corrosion in BWR type reactors; Metodos aplicados para la mitigacion del dano por corrosion bajo esfuerzo en reactores BWR

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez C, R.; Diaz S, A.; Gachuz M, M.; Arganis J, C. [Instituto Nacional de Investigaciones Nucleares, Gerencia de Ciencia de Materiales, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    1998-07-01

    The Boiling Water nuclear Reactors (BWR) have presented stress corrosion problems, mainly in components and pipes of the primary system, provoking negative impacts in the performance of energy generator plants, as well as the increasing in the radiation exposure to personnel involucred. This problem has caused development of research programs, which are guided to find solution alternatives for the phenomena control. Among results of greater relevance the control for the reactor water chemistry stands out particularly in the impurities concentration and oxidation of radiolysis products; as well as the supervision in the materials selection and the stresses levels reduction. The present work presents the methods which can be applied to diminish the problems of stress corrosion in BWR reactors. (Author)

  4. Las defensas inducidas en trigos comerciales

    OpenAIRE

    Càrdenas, David; Giménez, Daniel O.; Castro, Ana María

    2015-01-01

    Las plantas presentan múltiples tipos de estrategias de defensas ante sus patógenos y plagas y frente a estreses ambientales. En muchos casos las defensas constitutivas acarrean costos metabólicos altos que provocan mermas del rendimiento cuando no ocurren en el ciclo de cultivo ataquesde plagas o patógenos. Las defensas inducibles en cambio sólo se activan ante elicitores específicos producidos por la interacción con los agresores bióticos, si bien conllevan gastos energéticos sólo ocurre an...

  5. Detección de anticuerpos antiplasmodium por ELISA en donantes de sangre

    Directory of Open Access Journals (Sweden)

    Patricia Olaya de Morales

    1982-06-01

    Full Text Available La malaria, una enfermedad transmitida por mosquitos del genero anopheles, puede ser inducida a través de transfusiones de sangre infectada con alguna de las especies de Plasmodium que afectan al hombre. Con el objeto de determinar el riesgo potencial de infección inducida por transfusiones, se analizaron durante 9 meses y mediante la técnica de E.L.I.S.A., las muestras de suero tomadas a los donantes de sangre del Hospital Militar Central de Bogotá. El 8.6 por mil de las 3114 muestras analizadas, resultaron positivas para anticuerpos antimaláricos y durante el tiempo del estudio fueron detectados 3 casos de malaria inducida por transfusiones.

  6. Cracks propagation by stress corrosion cracking in conditions of Boiling Water Reactor (BWR); Propagacion de grietas por corrosion bajo esfuerzo en condiciones de reactor de agua hirviente (BWR)

    Energy Technology Data Exchange (ETDEWEB)

    Fuentes C, P

    2003-07-01

    This work presents the results of the assays carried out in the Laboratory of Hot Cells of the National Institute of Nuclear Research (ININ) to a type test tube Compact Tension (CT), built in steel austenitic stainless type 304L, simulating those conditions those that it operates a Boiling Water Reactor (BWR), at temperature 288 C and pressure of 8 MPa, to determine the speed to which the cracks spread in this material that is of the one that different components of a reactor are made, among those that it highlights the reactor core vessel. The application of the Hydrogen Chemistry of the Water is presented (HWC) that is one alternative to diminish the corrosion effect low stress in the component, this is gets controlling the quantity of oxygen and of hydrogen as well as the conductivity of the water. The rehearsal is made following the principles of the Mechanics of Elastic Lineal Fracture (LEFM) that considers a crack of defined size with little plastic deformation in the tip of this; the measurement of crack advance is continued with the technique of potential drop of direct current of alternating signal, this is contained inside the standard Astm E-647 (Method of Test Standard for the Measurement of Speed of Growth of Crack by fatigue) that is the one that indicates us as carrying out this test. The specifications that should complete the test tubes that are rehearsed as for their dimensions, it forms, finish and determination of mechanical properties (tenacity to the fracture mainly) they are contained inside the norm Astm E-399, the one which it is also based on the principles of the fracture mechanics. The obtained results were part of a database to be compared with those of other rehearsals under different conditions, Normal Chemistry of the Water (NWC) and it dilutes with high content of O{sub 2}; to determine the conditions that slow more the phenomena of stress corrosion cracking, as well as the effectiveness of the used chemistry and of the method of

  7. Respuesta del sistema antioxidante en varones sanos, frente a hiperglicemia aguda inducida

    Directory of Open Access Journals (Sweden)

    Raquel Oré

    2009-09-01

    Full Text Available Objetivo: determinar la respuesta del sistema antioxidante en varones sanos, frente a la hiperglicemia aguda inducida. Diseño: estudio prospectivo, descriptivo, longitudinal, experimental. Lugar: Instituto Nacional de Biología Andina, Facultad de Medicina, Universidad Nacional Mayor de San Marcos, Lima, Perú. Material biológico: Sangre y suero de sujetos aparentemente sanos. Intervenciones: A 13 sujetos adultos clínicamente sanos, entre 20 y 41años, después de 10 horas de ayuno, se administró glucosa vía endovenosa, mediante el método de clamp hiperglicémico, a 125 mg/dL por encima del valor basal, durante 120 minutos. Se realizó mediciones de la glicemia a 0, 5, 10, 15, 20, 30, 40, 50, 60, 70, 80, 90, 100, 110 y 120 minutos. Se tomó la muestra sanguínea con anticoagulante EDTA y otra de sangre total, para obtención de suero, para las pruebas bioquímicas a los 0, 60 y 120 minutos. Principales medidas de resultados: Modificaciones de la glicemia y lipoperoxidación en suero, glutatión y actividad superóxido dismutasa en glóbulos rojos lisados e índices de estrés oxidativo. Resultados: El nivel de glucosa durante el clamp hiperglicémico, luego de alcanzar el ‘equilibrio’, fue 197±17,58 mg/dL. La lipoperoxidación aumentó de 2,54 + 0,51 a 2,90 + 0,58 umol/L, de 0 a 60 minutos, y a 2,66 + 0,55 umol/L a los 120 minutos. El glutatión se redujo en 8,10% a la hora, aumentando 7,08% a los 120 minutos. La actividad superóxido dismutasa se elevó 0,54% a los 60 minutos y 5,66% a los 120 minutos, sobre el basal. Los índices de valoración del estrés oxidativo tuvieron correlación r Pearson positiva, en nivel alto a muy alto. Conclusiones: la hiperglicemia aguda inducida hasta 2 horas elevó el estrés oxidativo, promoviendo generación de defensa antioxidante, con síntesis de glutatión reducido de novo y mayor actividad de la superóxido dismutasa.

  8. Efeito da perda ponderal induzida pela cirurgia bariátrica sobre a prevalência de síndrome metabólica Efecto de la pérdida ponderal inducida por la cirugía bariátrica sobre la prevalencia de síndrome metabólico Effects of weight loss induced by bariatric surgery on the prevalence of metabolic syndrome

    Directory of Open Access Journals (Sweden)

    Francisco das Chagas Monteiro Júnior

    2009-06-01

    Full Text Available FUNDAMENTO: A síndrome metabólica (SM está frequentemente ligada ao excesso de peso e melhora com a perda ponderal, sendo esperado que essa melhora seja proporcional à intensidade dessa perda. OBJETIVO: Avaliar o impacto da perda ponderal induzida pela cirurgia bariátrica (CB sobre a prevalência da SM, em médio prazo. MÉTODOS: Foram analisados 35 pacientes submetidos à cirurgia de by-pass gastrojejunal em Y de Roux, no período de outubro de 2001 a outubro de 2005, em nosso HU, sendo 88,5% do sexo feminino, com uma média de idade de 37,8±11,1 anos e um IMC médio de 45,0±6,2 kg/m². Na primeira etapa da pesquisa, foram obtidos dados demográficos e clínico-antropométricos antes da realização da CB, incluindo os critérios para o diagnóstico da SM, de acordo com as diretrizes do NCEP dos Estados Unidos. Na segunda etapa, os pacientes operados foram reavaliados ambulatorialmente quanto à prevalência da SM. RESULTADOS:Antes da cirurgia, a SM foi diagnosticada em 27 pacientes (77,1%. Em reavaliação 34,4±15 meses após a cirurgia, observou-se uma queda do IMC médio para 28,3±5,0 kg/m² e a SM foi detectada em apenas dois pacientes (5,7% (pFUNDAMENTO: El síndrome metabólico (SM frecuentemente está vinculado al exceso de peso y mejora con la pérdida ponderal, esperándose que esta mejora sea proporcional a la intensidad de esa pérdida. OBJETIVO: Evaluar el impacto de la pérdida ponderal inducida por la cirugía bariátrica (CB sobre la prevalencia de la SM, a medio plazo. MÉTODOS: Se estudiaron 35 pacientes sometidos a cirugía de bypass gastroyeyunal en Y de Roux, en el período de octubre de 2001 a octubre de 2005, en nuestro HU, siendo el 88,5% del sexo femenino, con un promedio de edades de 37,8±11,1 años y un IMC promedio de 45,0±6,2 Kg/m². En la primera etapa de la investigación, se obtuvieron datos demográficos y clínico antropométricos antes de la realización de la CB, incluyendo los criterios para el

  9. Síndrome de Munchausen por mandato

    OpenAIRE

    Esteban, Miguel A.; Pérez, Miriam R.; Bracco, Anahí

    2006-01-01

    El Síndrome de Munchausen por mandato, "un trastorno ficticio, por el cual la enfermedad del niño es inducida, promovida o provocada por la persona más próxima a él, generalmente su madre", es todavía mal conocido y su génesis imperfectamente comprendida. Esta comunicación está destinada a esclarecer al pediatra esta patología, con elevada morbilidad y secuelas, como así también de altísima mo...

  10. Efecto hipolipidémico del extracto acuoso de las hojas de Artocarpus altilis "árbol del pan" en Rattus norvegicus con hiperlipidemia inducida

    Directory of Open Access Journals (Sweden)

    Julio Campos Florián

    2013-01-01

    Full Text Available La presente investigación tuvo como objetivo demostrar la actividad hipolipidémica del extracto acuoso de las hojas del árbol del pan, Artocarpus altilis, en un modelo de hiperlipidemia aguda inducida con tritón X-305, utilizando como especímenes Rattus norvegicus machos, peso promedio 204,5 g, a los que se les administró por vía oral 0,05 g/100 g y 0,2 g/100 g del extracto acuoso de A. altilis; se incluyó un grupo control negativo que recibió solución salina fisiológica y un grupo control positivo hiperlipidémico. Luego de 24 horas de administrar los tratamientos, se realizaron las mediciones en suero de las concentraciones de colesterol y triglicéridos. Encontramos reducciones significativas (p < 0,01 tanto de las cifras de colesterol, como de triglicéridos en relación a las concentraciones obtenidas en el grupo control positivo. También encontramos diferencia significativa (p < 0,01 entre las concentraciones de triglicéridos de los animales tratados con las dos dosis del extracto acuoso de A. altilis. Concluimos que el extracto acuoso de las hojas de A. altilis presenta efecto hipolipidémico a las dosis ensayadas para el modelo de hiperlipidemia inducida con tritón X-305.

  11. Theorical and experimental study of the induced forces by the mixed, divergent, convergent and straight labyrinth of seal systems on the steam turbines, gas turbines and compressor rotors; Estudio teorico-experimental de las fuerzas inducidas por los sistemas de sellos de laberinto rectos, convergentes, divergentes y mixtos sobre los rotores de turbinas de vapor, turbinas de gas y compresores

    Energy Technology Data Exchange (ETDEWEB)

    Salazar San Andres, Octavio Ramon

    1991-12-31

    demuestran que el modelo es capaz de dar una vision cualitativa y cuantitativa de las fuerzas y los coeficientes de rigidez y amortiguamiento de los sellos de laberinto con las geometrias antes mencionadas, tanto para el rotor estatico como en operacion. Por otra parte se recomienda llevar a cabo mas experimentacion con equipo instalado en plantas termoelectricas y en especial en turbinas de vapor con capacidades iguales o superiores a los 300 MW, donde las altas presiones y los sellos localizados en la parte superior de los alabes, vuelven mas susceptibles a las maquinas para autoinducir vibraciones subsincronas.

  12. Efeitos da fadiga muscular induzida por exercícios no tempo de reação muscular dos fibulares em indivíduos sadios Efectos de la fatiga muscular inducida por ejercicios sobre el tiempo de reacción muscular peronea en individuos sanos Effects of the exercise-induced muscular fatigue on the time of muscular reaction of the fibularis in healthy individuals

    Directory of Open Access Journals (Sweden)

    Bruno Araújo Rego Santos Silva

    2006-04-01

    Full Text Available A fadiga muscular (FM é um fenômeno comum nas atividades esportivas e diárias, resultando numa piora da performance motora. Ela é considerada um dos fatores causadores de lesões músculo-esqueléticas. A entorse de tornozelo é um exemplo: a FM afetaria tanto o sistema aferente quanto o eferente. Vários estudos têm analisado a influência da FM no controle neuromuscular (CNM; entretanto, existe pouca pesquisa sobre essa influência na velocidade de reação dos músculos. O objetivo deste estudo foi verificar os efeitos da FM no tempo de reação muscular (TRM dos músculos fibulares, que são os primeiros a responder a um estresse em inversão do tornozelo. Foram estudados 14 indivíduos saudáveis masculinos (idade: 20-35 anos, que tiveram seus TRM avaliados por meio de eletromiografia (EMG de superfície. O início da atividade muscular foi definido como a média de repouso + 3x o desvio-padrão (DP. O TRM dos fibulares foi mensurado após uma inversão súbita de 20º realizada numa plataforma. A inversão súbita foi realizada antes e depois da fadiga muscular, que foi induzida por exercícios localizados dos fibulares até a exaustão. Os resultados mostraram que houve um aumento significativo do tempo de reação muscular após a fadiga (p La fatiga muscular (FM es un fenómeno común en las actividades diarias, produciendo un empeoramiento de la actuación. Se la considera una de las causas de factores lesionantes musculares de esqueleto. El esguince del tobillo es un ejemplo: La FM afectaría tanto el sistema aferente cuanto el eferente. Varios estudios han estado analizando la influencia de FM en el comando neuromuscular (CNM, sin embargo, la existen pocas investigaciones sobre la influencia en la velocidad de reacción de los músculos. El objetivo de ese estudio era verificar los efectos de FM en el tiempo de reacción muscular (TRM de los músculos peroneos, que son los primeros en responder a una tensión en la inversi

  13. Períodos perturbados: disipación de energía y corrientes geomagnéticas inducidas

    Directory of Open Access Journals (Sweden)

    Patricia A. Larocca

    2010-06-01

    Full Text Available Se estudia, en un evento típico (12-13 de junio de 2005 las energías entrante y disipada en la magnetosfera ( y Ut respectivamente y el aumento de corrientes inducidas en un gasoducto ubicado en altas latitudes. Se analizan para el período citado los índices geomagnéticos AE y Dst, y la componente Bz del campo geomagnético interplanetario como indicadores del desarrollo del período perturbado. Se calculan los tiempos de decaimiento del anillo de corriente utilizando distintas aproximaciones de acuerdo con las fases de la tormenta. Durante este período se observaron variaciones geomagnéticas importantes que originaron corrientes geomagnéticas inducidas significativas sobre el gasoducto de la empresa Transcanada ubicado en la zona del valle del río Ottawa; pudiendo ser afectada la vida útil del mismo.In a typical event (12-13 June 2005, solar wind energy rate and total energy dissipation rate in the magnetosphere (e and Ut respectively and increased induced currents in a gas pipe located in the auroral zone are studied. For the period geomagnetic indices AE and Dst, and the Bz component of the interplanetary geomagnetic field are analyzed as indicators of the development of the troubled period. Ring current decay times are calculated using different approaches in accordance with the phases of the storm. During this period there were significant geomagnetic variations due to geomagnetic substorms and induced currents on the pipeline located in the Otawa River Valley, this fact could produce corrosion increases in its structure.

  14. Pitting corrosion behaviour study of aluminium matrix composites (A3xx.x/SiCp); Estudio del comportamiento a la corrosion por picadura de materiales compuestos de matriz de aluminio (A3xx.x/SiCp)

    Energy Technology Data Exchange (ETDEWEB)

    Pardo, A.; Merino, M. C.; Merino, S.; Lopez, M. D.; Viejo, F.; Carboneras, M.; Arrabal, R.

    2004-07-01

    The influence of the SiCp proportion on the pitting corrosion of A3xx.x/SiC/xxp composites was studies by means of potenciodinamic polarization and double cyclic polarization in saline environment at 25 degree centigree A360/SiC/xxp matrix does not contain copper, whereas the A380/SiC/xxp matric contains 1,39-1,44 wt %Cu. The kinetic study was carried out by gravimetric measurements. The nature of corrosion products was analysed by low angle XRD and Scanning Electron Microscopy (SEM). The corrosion is due to nucleation and growth of Al{sub 2}O{sub 3}-3H{sub 2}O on the material surface. The corrosion increases with the reinforcement proportion, chloride concentration and copper content. (Author) 10 refs.

  15. Corrosion and corrosion control

    International Nuclear Information System (INIS)

    Khanna, A.S.; Totlani, M.K.

    1995-01-01

    Corrosion has always been associated with structures, plants, installations and equipment exposed to aggressive environments. It effects economy, safety and product reliability. Monitoring of component corrosion has thus become an essential requirement for the plant health and safety. Protection methods such as appropriate coatings, cathodic protection and use of inhibitors have become essential design parameters. High temperature corrosion, especially hot corrosion, is still a difficult concept to accommodate in corrosion allowance; there is a lack of harmonized system of performance testing of materials at high temperatures. In order to discuss and deliberate on these aspects, National Association for Corrosion Engineers International organised a National Conference on Corrosion and its Control in Bombay during November 28-30, 1995. This volume contains papers presented at the symposium. Paper relevant to INIS is indexed separately. refs., figs., tabs

  16. Dictionary corrosion and corrosion control

    International Nuclear Information System (INIS)

    1985-01-01

    This dictionary has 13000 entries in both languages. Keywords and extensive accompanying information simplify the choice of word for the user. The following topics are covered: Theoretical principles of corrosion; Corrosion of the metals and alloys most frequently used in engineering. Types of corrosion - (chemical-, electro-chemical, biological corrosion); forms of corrosion (superficial, pitting, selective, intercrystalline and stress corrosion; vibrational corrosion cracking); erosion and cavitation. Methods of corrosion control (material selection, temporary corrosion protection media, paint and plastics coatings, electro-chemical coatings, corrosion prevention by treatment of the corrosive media); Corrosion testing methods. (orig./HP) [de

  17. Efecto protector en cirrosis hepática inducida en ratas del extracto etanólico de las hojas de Piper aduncum comparado con silimarina

    Directory of Open Access Journals (Sweden)

    Jorge Arroyo

    2012-04-01

    Full Text Available Objetivos: Evaluar la eficacia protectora del extracto etanólico de hojas de Piper aduncum (matico y su fitomedicamento en cápsulas, en la cirrosis hepática inducida en ratas. Diseño: Experimental. Lugar: Facultad Medicina, Universidad Nacional Mayor de San Marcos, Lima, Perú. Material biológico: Hojas de Piper aduncum, y Rattus norvegicus, cepa Holtzman. Intervenciones: Las hojas fueron recolectadas en el distrito de Huariaca, departamento de Pasco. El fitomedicamento en cápsulas se preparó a partir del extracto etanólico de la planta. La cirrosis fue inducida con fenobarbital 0,5 mg/mL, diluida en el agua de beber por 15 días, y luego, tetracloruro de carbono 0,2mL/kg en aceite de oliva 1:1, oralmente por 7 días. Se colectó una muestra de sangre para determinar perfil hepático y malondialdehído; los animales fueron sacrificados extrayéndose el hígado para estudio histopatológico. Los datos fueron evaluados mediante técnicas multivariadas, con valor p < 0,05. Principales medidas de resultados: Grado de lesión hepática, marcadores bioquímicos, estrés oxidativo. Resultados: El extracto y el fitomedicamento a 200 mg/kg disminuyeron los valores de TGP (p < 0,621, bilirrubina total (p < 0,385 y bilirrubina directa (p < 0,283 e incrementaron las proteínas totales (p < 0,539 y albúmina (p < 0,114, similar al grupo silimarina. El colágeno, la fibrosis y el nivel de daño hepático se vieron aumentados con tetracloruro de carbono; estos indicadores se redujeron con los diferentes tratamientos y la silimarina. El marcador de estrés oxidativo se redujo con los tratamientos aplicados (p < 0,002. Conclusiones: El extracto etanólico de las hojas de Piper aduncum (matico y su fitomedicamento ejercieron efecto protector de la cirrosis inducida en ratas, comparativamente con la silimarina.

  18. Chromosomal aberrations induced by alpha particles; Aberraciones cromosomicas inducidas por particulas {alpha}

    Energy Technology Data Exchange (ETDEWEB)

    Guerrero C, C.; Brena V, M. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)]. e-mail: cgc@nuclear.inin.mx

    2005-07-01

    The chromosomal aberrations produced by the ionizing radiation are commonly used when it is necessary to establish the exposure dose of an individual, it is a study that is used like complement of the traditional physical systems and its application is only in cases in that there is doubt about what indicates the conventional dosimetry. The biological dosimetry is based on the frequency of aberrations in the chromosomes of the lymphocytes of the individual in study and the dose is calculated taking like reference to the dose-response curves previously generated In vitro. A case of apparent over-exposure to alpha particles to which is practiced analysis of chromosomal aberrations to settle down if in fact there was exposure and as much as possible, to determine the presumed dose is presented. (Author)

  19. Polymerization of sodium methacrylate induced by irradiation; Polimerizacion del metacrilato de sodio inducida por la irradiacion

    Energy Technology Data Exchange (ETDEWEB)

    Galvan S, A. [Instituto Nacional de Investigaciones Nucleares, Gerencia de Ciencias Basicas, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    1998-07-01

    This work has two objectives, first: it is pretended to localize the lines of carbon links in its IR spectra, and second: following the polymerization of sodium methacrylate according to that it is irradiated with gamma rays. (Author)

  20. ALERGIA EN EL HUMANO INDUCIDA POR LA SALIVA DE INSECTOS DE LA FAMILIA CULICIDAE

    Directory of Open Access Journals (Sweden)

    Ligia Inés Moncada Álvarez

    2011-04-01

    Full Text Available Se hace una revisión de las moléculas que inoculan los insectos de la familia Culicidae al momento de la picadura y los mecanismos que muestran sus hospederos para contrarrestarlos y cómo algunas de esas moléculas, especialmente las enzimas se convierten en alérgenos que inducen una respuesta de amplio espectro, que va desde una pápula al momento de la picadura hasta una reacción anafiláctica. De la misma manera se analizan las posibilidades de diagnóstico con moléculas silvestres y antígenos recombinantes, lo mismo que pautas de tratamiento.

  1. Estudio morfométrico de las malformaciones craneofaciales experimentales inducidas por ácido retinoico

    Directory of Open Access Journals (Sweden)

    T. González

    2003-10-01

    Full Text Available Objetivo: El ácido retinoico es un metabolito activo de la vitamina A que administrado en grandes cantidades tiene efecto teratógeno sobre la embriogénesis de los mamíferos. Hemos investigado los efectos de la exposición temprana de embriones de rata sobre las estructuras craneofaciales. Diseño: Cuarenta y cinco ratas Sprague-Dawley gestantes fueron tratadas con 125 mg/kg de ácido all-trans-retinoico el día 10 de gestación. Las 20 ratas controles fueron tratadas con aceite. Los fetos de ambos grupos se extrajeron el día antes de llegar a término y fueron sometidos a un estudio morfológico y otro estudio morfométrico, analizando las malformaciones craneofaciales. Resultados: Ninguno de los fetos controles presentó malformaciones. El 100% de los embriones tratados con retinoico presentaron defectos craneofaciales, incluyendo fisuras faciales, exoftalmos, malformaciones e inserción baja de los pabellones auriculares, apéndices faciales y anomalías nasales. El análisis morfométrico reveló un incremento de la distancia entre los poros nasales (pObjective: Retinoic acid is an active metabolite of Vitamin A that is teratogenic when present in excess during mammalian embriogenesis. We have investigated the effects of early exposure of rat embryos to retinoic acid on craniofacial structures. Design: Treatment of 45 pregnant Sprague-Dawley rats with 125mg./Kg all-trans-retinoic acid on pregnancy day 10 was performed. Twenty controls were treated only with oil. The fetuses were recovered the day before term, and both morphologic and morphometric analyses of the craniofacial structures were performed. Results: None of the control fetuses had malformations. Craniofacial defects were observed in 100% of the retinoic embryos including facial clefts, proptosis, abnormalities and inferior placement of the pinnae, skin tags, and nasal anomalies. Morphometric analyses revealed an increased distance between nasal pores (p<0,01 and between both eyes (p<0,05 in retinoic embryos. A reduced distance of the maxilla (p<0,01 and the mandible (p<0,01 were also noted. Conclusions: Morphologic and morphometric studies confirm the hypothesis that retinoic acid disturbs normal craniofacial development when administered during a critical period. Hindrance of migration of the cranial neural crest cells may be a main reason to explain these events.

  2. Respuesta inmune mucosal inducida por proteoliposoma y cocleato derivados de N. meningitidis serogrupo B

    Directory of Open Access Journals (Sweden)

    Judith del Campo

    2009-08-01

    Full Text Available Mucosal vaccination offers attractive advantages to conventional systemic vaccination. Most pathogens enter or establish infection at mucosal surfaces. This represents an enormous challenge for vaccine development. Nevertheless, the availability of safe and effective adjuvants that function mucosally is the major limitation. Therefore, we investigated the impact of mucosal immunization with the Neisseria meningitidis B proteoliposome (AFPL1, Adjuvant Finlay Proteoliposome 1 and its-derived cochleate (Co, AFCo1. They contain multiple PAMPs as immunopotentiators and have delivery system ability as well as Th1 polarization activity. Groups of female mice were immunized by nasal, oral, intravaginal, or intramuscular routes with three doses with AFPL1/AFCo1 alone or containing ovalbumin or glycoprotein (g D2 from Herpes Simplex Virus type 2 (HSV-2. High levels of specific IgG antibodies were detected in sera of mice vaccinated with either route. However, specific IgA antibodies were produced in saliva and vaginal wash only following mucosal delivering. The polarization to a Th1 pattern was confirmed by testing the induction of IgG2a/IgG2c antibody, positive delayed-type hypersensitivity reactions, and gIFN production. Additionally, AFCo1gD2 showed practically no vaginal HSV-2 replication and 100% protection against lethal vaginal HSV-2 challenge. In conclusion, the results support the use of AFCo1 as potent Th1 adjuvant for mucosal vaccines, particularly for nasal route.

  3. Muerte celular inducida por condiciones ambientales adversas en Calibrachoa parviflora (Petunia

    Directory of Open Access Journals (Sweden)

    Daniela Montes Berrueta

    2012-03-01

    Full Text Available Se ha descrito que condiciones ambientales extremas tales como altas temperaturas, luz ultravioleta y el efecto invernadero, alteran la tasa de crecimiento de las plantas. En este trabajo se investigó el efecto agudo de dos condiciones ambientales extremas tales como la limitación de nutrientes y la acidificación del suelo con ácido sulfúrico, un compuesto comúnmente depositado en los suelos como consecuencia de la llamada lluvia ácida, sobre la tasa de muerte y proliferación celular en petunias (Calibrachoa parviflora. Para tales efectos, grupos de petunias fueron sometidas a tres condiciones diferentes: grupo A o control, mantenida en condiciones óptimas y de suministro de nutrientes, grupo B en ausencia de nutrientes y de luz natural, y grupo C expuestas a agua acidificada con ácido sulfúrico. En un seguimiento hasta 72 horas, se analizaron muestras de pétalos, hojas y tallos de cada una de las plantas y, posterior a la extracción de los núcleos, estos fueron teñidos con ioduro de propidio, un agente intercalante del ADN, y analizados mediante citometría de flujo y microscopía de fluorescencia. Los resultados muestran que ambas condiciones extremas generan un desbalance en el proceso de muerte/sobrevida de las petunias, pero a diferencia de las plantas del grupo B, las plantas del grupo C no incrementaron la tasa de proliferación celular. Estos resultados sugieren que las plantas que crecen en suelos ácidos pierden la capacidad compensatoria ante la señal de estrés que se genera a consecuencia de la exposición aguda a concentraciones tóxicas de ácido sulfúrico. Cell death induced by adverse environmental conditions in Calibrachoa parviflora (petunia Abstract It has been previously reported that extreme environmental conditions such as high temperatures, ultraviolet light and the greenhouse effect, alter the rate of growth in plants. In this study we investigated the acute effect of two extreme environmental conditions: nutrient deprivation and soil acidification with sulfuric acid, a compound commonly deposited in the soil, as a result of acid rain, on the rate of death and cell proliferation in petunias (Calibrachoa parviflora. For this purpose, a group of petunias was subjected to three different conditions: group A or control, kept in optimum conditions and nutrient supply, group B in the absence of nutrients and natural light and group C, exposed to water acidified with sulfuric acid. In continuous observations for up to 72 hours, samples from petals, leaves and stems of each plant were analyzed and after nuclei extraction; these were treated with propidium iodide, a DNA intercalator compound, and analyzed by flow cytometry and fluorescence microscopy. The results show that both extreme conditions generate an imbalance in the process of death/survival of petunias, but unlike plants from group B, plants in group C, did not increase their rate of cell proliferation. These results suggest that plants growing in acid soils lose their ability to compensate the stress signal generated as a result of acute exposure to toxic concentrations of sulfuric acid.

  4. Prevalencia y severidad de la disfunción intestinal inducida por opioides

    Directory of Open Access Journals (Sweden)

    Rafael Gálvez

    2014-01-01

    Conclusiones: En pacientes con tratamiento opioide se constata una elevada frecuencia de trastornos gastrointestinales posiblemente relacionados con la DIO, lo que subraya la necesidad de nuevas estrategias para su tratamiento.

  5. MECANISMOS CELULARES IMPLICADOS EN EL DESARROLLO DE HIPERTROFIA DEL MUSCULO ESQUELETICO INDUCIDA POR TESTOSTERONA

    OpenAIRE

    BASUALTO ALARCON, CARLA EDITH

    2012-01-01

    El músculo esquelético es un tejido blanco para la acción de los esteroides anabólicos, siendo la testosterona la principal hormona fisiológica. Esta hormona actúa diferencialmente durante el desarrollo de un individuo cumpliendo roles diversos en el período embrionario, en la pubertad y en la vida adulta. Se ha demostrado que la testosterona es capaz de inducir un incremento en la masa muscular de individuos adultos tratados con dosis supra-fisiológicas, sin embargo los mecanismos c...

  6. Efecto hipolipidémico del extracto acuoso de las hojas de Artocarpus altilis "árbol del pan" en Rattus norvegicus con hiperlipidemia inducida

    OpenAIRE

    Julio Campos Florián

    2013-01-01

    La presente investigación tuvo como objetivo demostrar la actividad hipolipidémica del extracto acuoso de las hojas del árbol del pan, Artocarpus altilis, en un modelo de hiperlipidemia aguda inducida con tritón X-305, utilizando como especímenes Rattus norvegicus machos, peso promedio 204,5 g, a los que se les administró por vía oral 0,05 g/100 g y 0,2 g/100 g del extracto acuoso de A. altilis; se incluyó un grupo control negativo que recibió solución salina fisiológica y un grupo control po...

  7. Efecto del extracto del fruto de Physalis peruviana "tomatillo" en Mus musculus var. swis con hiperlipidemia inducida.

    Directory of Open Access Journals (Sweden)

    Julio Campos Florián

    2011-01-01

    Full Text Available El objetivo de la presente i nvestigación fue determinar la actividad hipolipidémica del fruto de Physalis peruviana “tomatillo” en un modelo de hiperlipidemia aguda inducida con tritón. Se utilizaron Mus musculus var. swis machos como animales de experimentación. Se trabajó con cuatro grupos de ratones, el grupo blanco recibió agua destilada por vía oral y solución salina fisiológica por vía intraperitoneal, el grupo control recibió agua destilada por vía oral y tritón por vía intraperitoneal, el grupo problema 1 recibió por vía oral 0.05g/100g del extracto de Physalis peruviana y tritón por vía intraperitoneal y el grupo problema 2 recibió por vía oral 0.2g/100g del extracto de Physalis peruviana y tritón por vía intraperitoneal. Luego de 24 horas de administrar los tratamientos se re alizaron las mediciones en suero de las concentraciones de colesterol y triglicéridos. Los niveles promedio de colesterol (mg/dL fueron: 58.87±11.54 (blanco, 121.71±15.00 (control, 58.08±9. 21 (problema 1 y 66.78±16.77 (problema 2. Los niveles promedio de triglicéridos (g/L fueron: 0.48±0.07 (blanco, 1.84±0.18 (control, 0.34±0.10 (problema 1 y 0.94±0.25 (problema 2. Se encontró reducciones significativas (p<0.000, tanto de las concentraciones de colesterol como de triglicéridos en relación a las o btenidas en el grupo tratado sólo con tritón.

  8. Finite element model for expansive stress due to corrosion of reinforced concrete structures; Analisis con elemento finito de los esfuerzos expansivos por corrosion en las estructuras de concreto reforzado

    Energy Technology Data Exchange (ETDEWEB)

    Castorena Gonzalez, J.H.; Calderon Guillen, J.A. [Universidad Autonoma de Sinaloa, Los Mochis, Sinaloa (Mexico)]. E-mail: kstor28@yahoo.com.mx; cajoel_99@yahoo.com; Almeraya Calderon, F.; Gaona Tiburcio, C. [Centro de Investigacion en Materiales Avanzados, S.C., Chihuahua, Chihuahua (Mexico)]. E-mail: facundo.almeraya@cimav.edu.mx; citlalli.gaona@cimav.edu.mx; Almaral Sanchez, J.L. [Universidad Autonoma de Sinaloa, Los Mochis, Sinaloa (Mexico)]. E-mail: jalmaral@gmail.com; Martinez Villafane, A. [Centro de Investigacion en Materiales Avanzados, S.C., Chihuahua, Chihuahua (Mexico)]. E-mail: martinez.villafane@cimav.edu.mx

    2011-01-15

    The corrosion in the reinforcement steel is a problem that diminishes the useful life of reinforced concrete structures, reside committing its structural security. In the available models to estimate the mechanical effect of the corrosion, it is assumed that the corroded steel, through the oxides that grow to its surroundings, exercises a pressure on the surrounding concrete supposing a problem of plane stress or plane strain. In this work, the problem is modeled with three-dimensional finite element starting from an experiment on a subjected cylinder to accelerated corrosion, with strain gage to measure the pressure indirectly in the interface steel-concrete. From the results obtained it can be concluded that the effect of the length of corroded steel, anodic length, has a significant effect on the magnitude of the pressure in the interface steel-concrete, fact that can be used to improve the existing models. [Spanish] La corrosion en el acero de refuerzo es un problema que disminuye la vida util en las estructuras de concreto reforzado, ademas de comprometer su seguridad estructural. En los modelos disponibles para estimar el efecto mecanico de la corrosion, se supone que el acero corroido, a traves de los oxidos que crecen a su alrededor, ejercen una presion sobre el concreto circundante suponiendo un problema de esfuerzos o deformaciones planas, En el presente trabajo, se modela el problema con elemento finito tridimensional a partir de un experimento sobre un cilindro de concreto reforzado sometido a corrosion acelerada, instrumentado para medir indirectamente la presion en la interfase acero-concreto. De los resultados obtenidos se concluye que el efecto de la longitud de acero corroido, longitud anodica, tiene un efecto significativo sobre la magnitud de la presion en la interfase acero-concreto, hecho que puede ser utilizado para mejorar los modelos existentes.

  9. Procesos de corrosión debidos a corrientes alternas inducidas (60 Hz

    Directory of Open Access Journals (Sweden)

    Vera, E.

    1996-10-01

    Full Text Available The phenomenon by which a sinusoidal a.c. signal damages a steel in contact with an aggressive electrolite was determined. Thus, a series of electrochemical tests was carried out, when a signal of the previously mentioned characteristics is present in the metal-electrolite interphase, both with cathodic protection and without it. The results allowed to postulate an empirical relationship that determines the corrosive process kinetics exerted by the action of an alternating signal. The phenomenon by which the AC signal generates a corrosion state over a probe was determined from the physical point of view.

    Se determinó el fenómeno por el que una señal de c.a. de tipo sinusoidal genera fenómenos de corrosión en un acero en contacto con un electrólito agresivo. Para ello, se realizaron pruebas electroquímicas cuando una señal de las anteriores características está presente en la interfase metal-electrólito, con y sin protección catódica. Los resultados permitieron postular una relación empírica que determina la cinética del proceso corrosivo ejercido por la acción de la señal alterna. Se determinó, desde un punto de vista físico, el fenómeno por el cual la señal de c.a. genera un estado de corrosión sobre la probeta.

  10. Cross-Sections for Low-Energy Neutron-Induced Fission; Sections Efficaces de Fission pour des Neutrons de Faible Energie; 0421 0415 0427 0415 041d 0418 042f 0414 0415 041b 0415 041d 0418 042f , 0412 042b 0417 0412 0410 041d 041d 041e 0413 041e 041d 0415 0419 0422 0420 041e 041d 0410 041c 0418 041d 0418 0417 K 041e 0419 042d 041d 0415 0420 0413 0418 0418 ; Secciones Eficaces en la Fision Inducida por Neutrones de Baja Energia

    Energy Technology Data Exchange (ETDEWEB)

    Rae, E. R. [Atomic Energy Research Establishment, Harwell, Didcot, Berks. (United Kingdom)

    1965-07-15

    charge des noyaux cibles fournit egalement de nombreux renseignements sur la structure des noyaux lourds. Dans le cas d'un noyau cible susceptible de fission thermique, lorsque l'energie des neutrons augmente, la section efficace presente d'abord des variations inversement proportionnelles a la vitesse, puis une region ou des pics de resonance aigus apparaissent, et en dernier lieu une region de continu caracterisee par des variations relativement regulieres. Tous ces phenomenes peuvent recevoir une explication theorique, mais il semble tres difficile d'expliquer quantitativement certaines caracteristiques des donnees. Lors de mesures recentes de sections efficaces destinees a repondre aux besoins de la technologie des reacteurs, les chercheurs se sont surtout efforces d'ameliorer la resolution en energie ainsi que la precision des donnees relatives aux combustibles; ils ont ete ainsi amenes a etudier plus en detail la region de resonance qui a un grand interet pour les calculs de l'effet Doppler dans les reacteurs. Des mesures plus precises a des niveaux d'energie assez eleves ont fait apparaitre dans certains cas l'existence de sections efficaces de fission assez importantes en dessous du seuil d'energie de fission. Ces mesures ont ensuite appele l'attention des chercheurs sur l'interpretation des sections efficaces en fonction de modeles nucleaires qui reposent sur des donnees quantitatives sures. Le memoire expose les principales caracteristiques des sections efficaces de fission par neutrons et en donne une interpretation. Il met l'accent sur les ameliorations qui ont recemment ete apportees a la qualite des mesures et aux essais d'interpretation quantitative de certains aspects des donnees recueillies. (author) [Spanish] Las secciones eficaces de fision, inducida por neutrones, de los nucleos pesados son de fundamental importancia para la tecnologia de la produccion de energia nuclear. Asimismo, la manera en que estas secciones eficaces varian segun la energia

  11. Study of corrosion in metallic coating in steel-carbon by thermal spray; Estudo de corrosao em revestimentos metalicos em aco-carbono obtidos por aspersao termica

    Energy Technology Data Exchange (ETDEWEB)

    Cruz, Maria C.P.; Cavalcanti, Eliane B.; Rambo, Elisabeth S.M.; Araujo, Paulo M.M. [Instituto de Tecnologia e Pesquisa (IPT), Aracaju, SE (Brazil); Santos, Anderson O. [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil)

    2008-07-01

    The effect caused for constituent elements of the watery environment of production of the oil on metallic coverings was studied that simulate the artificial rise of the oil (connecting rods of pump mechanic). For in such a way, the techniques of electrochemical analysis had been used, as the method of linear polarization and the extrapolation of the straight line of Tafel of metallic coverings [alloy of Bronze and Aluminum; alloy of CrNi 80/20; NiCr 80/20; 95MXC (Cr: 26.5% - 31.5%, Cr: 26.5% - 31.5%, B: 3.35% - 4.15%, Mn: 1.1% - 2.2%, Itself: 1.1% -2.1%, Faith) and aluminum] on the substratum steel simulating covering in the connecting rods of pump. Oil well had been raised the resistance characteristics the polarization of the metal when submitted to the watery way surrounding it. They had been evaluated the resistance the covering polarization applied on the steel, with the objective to analyze its resistance the corrosion and to verify the possibility of its use as barrier against the problems originated for the degradation in connecting rods of pump. For the calculated Taxes of Corrosion, it can be concluded that the Aluminum coverings (0,003 mm/year) and NiCr 80/20 (0,179 mm/year) had been the ones that had presented a bigger resistance to the corrosive way. (author)

  12. Efecto hepatoprotector del extracto hidroetanólico atomizado del maíz morado (Zea mays L. en lesiones hepáticas inducidas en ratas

    Directory of Open Access Journals (Sweden)

    Renán Hañari-Quispe

    2015-04-01

    Full Text Available Objetivos: Evaluar el efecto hepatoprotector del extracto hidroetanólico atomizado de Zea mays variedad morado sobre lesiones hepáticas inducidas en ratas. Diseño: Experimental. Institución: Laboratorio de Farmacología Experimental, Facultad de Medicina Humana, Universidad Nacional Mayor de San Marcos, Lima, Perú. Material biológico: Extracto hidroetanólico atomizado de maíz morado (EAM. Intervenciones: Se formó seis grupos de ratas machos (n=10, por cada grupo, se les administró fenobarbital a concentración de 0,5 g/L en agua potable ad líbitum por 15 días; posteriormente se administró tetracloruro de carbono (CCl a una dosis de 0,2 mL/kg, por vía oral. El diseño experimental fue el siguiente: G1: suero fisiológico (SSF; G2: CCl0,2 mL/kg (T;4G3: T+ 4 silimarina 25 mg/kg; G4: T + EAM 500 mg/kg; G5: T + EAM 1 000 mg/kg; G6: T + EAM 2 000 mg/kg. Principales medidas de resultados: Perfil hepático, especies reactivas al ácido tiobarbitúrico (TBARS en suero, índice hepático, observación histológica. Resultados: Se observó aumento significativo (p<0,05 en la actividad de alanina amino transferasa (ALT entre el grupo G2 y los grupos G3 y G4 (p<0,001. Hubo disminución significativa (p<0,05 de fosfatasa alcalina (FAL en el grupo G2 con respecto G1. El nivel de TBARS fue menor en el grupo que recibió 1 000 mg/kg de EAM con respecto al control. Las actividades de HDL-C y triglicéridos no mostraron diferencias significativas. Se ha observado la reducción de 60% de la lesión hepática, evidenciado con menor daño del hepatocito al estudio histológico. Conclusiones: El extracto hidroetanólico atomizado de maíz morado a la dosis de 1 000 mg/kg disminuyó las lesiones hepáticas inducidas en ratas.

  13. Radio-tracer techniques in the study of corrosion by molten fluorides; Etude, a l'aide d'indicateurs radioactifs, de la corrosion provoquee par les fluorures fondus; Primenenie metodov radioaktivnykh indikatorov nrn izuchenii korrozii, prichinyaemoj rasplavlennymi ftoristymi soedineniyami; Estudio con indicadores radiactivos de la corrosion ocasionada por fluoruros fundidos

    Energy Technology Data Exchange (ETDEWEB)

    Grimes, W R; Watson, G M; DeVan, J H; Evans, R B [Oak Ridge National Laboratory, Oak Ridge, TN (United States)

    1962-03-15

    coefficients de diffusion mesures experimentalement; il est permis d'en conclure que le coefficient d'autodiffusion du chrome est insensible aux modifications de la teneur en chrome de l'alliage Inor-8. (author) [Spanish] Si se someten el Inconel o el Inor-8 a la accion de una mezcla de fluoruros fundidos, que contenga sustancias reducibles, el cromo sufre una oxidacion selectiva y es extraido de la aleacion. Con ayuda del indicador radiactivo {sup 51}Cr, los autores han evaluado los coeficientes de autodifusion del cromo en el Inconel y en el lnor-8, y han comprobado que los datos obtenidos son validos para las aleaciones expuestas a la corrosion. Han calculado los coeficientes globales 1) midiendo el paso del {sup 51}Cr de las capsulas de aleacion (empleado en forma do CrF{sub 2}) a los fluoruros no corrosivos fundidos, y 2) comparando la radiactividad total medida en las muestras de aleacion expuestas con la radiactividad de la sal a cuya accion fueron sometidas. Ademas, calcularon los coeficientes midiendo los perfiles do concentracion del indicador por pulidos electroliticos sucesivos de las muestras. Los coeficientes globales y los obtenidos por pulido electrolitico concuerdan satisfactoriamente para el Inconel a temperaturas elevadas, y para el lnor-8 a todas las temperaturas. Los valores obtenidos por pulido electrolitico del Inconel tratado a temperaturas inferiores a 760{sup o} C superan a los valores globales; en este caso, el proceso de difusion masica no es uniforme. Los coeficientes medios de difusion encontrados concuerdan siempre con los que se calculan por extrapolacion de los valores publicados, que fueron obtenidos con aleaciones de Cr-Ni similares, a temperaturas mas elevadas. Los autores se sirvieron de un par de buees politermicos de Inor-8 para hacer circular una masa de fluoruros no corrosivos fundidos que contenian {sup 51}Cr (en forma de CrF{sub 2}). Sacrificaron uno de estos bucles para evaluar la cantidad de {sup 51}Cr absorbida por la aleacion; el

  14. Corrosion cracking

    International Nuclear Information System (INIS)

    Goel, V.S.

    1985-01-01

    This book presents the papers given at a conference on alloy corrosion cracking. Topics considered at the conference included the effect of niobium addition on intergranular stress corrosion cracking, corrosion-fatigue cracking in fossil-fueled-boilers, fracture toughness, fracture modes, hydrogen-induced thresholds, electrochemical and hydrogen permeation studies, the effect of seawater on fatigue crack propagation of wells for offshore structures, the corrosion fatigue of carbon steels in seawater, and stress corrosion cracking and the mechanical strength of alloy 600

  15. Corrosion engineering

    Energy Technology Data Exchange (ETDEWEB)

    Fontana, M.G.

    1986-01-01

    This book emphasizes the engineering approach to handling corrosion. It presents corrosion data by corrosives or environments rather than by materials. It discusses the corrosion engineering of noble metals, ''exotic'' metals, non-metallics, coatings, mechanical properties, and corrosion testing, as well as modern concepts. New sections have been added on fracture mechanics, laser alloying, nuclear waste isolation, solar energy, geothermal energy, and the Statue of Liberty. Special isocorrosion charts, developed by the author, are introduced as a quick way to look at candidates for a particular corrosive.

  16. Manifestaciones reumáticas de la infección por el virus de inmunodeficiencia humana (VIH

    Directory of Open Access Journals (Sweden)

    Gloria María Vásquez Duque

    2005-02-01

    Full Text Available Con la aparición del VIH/SIDA se ha puesto de manifiesto un espectro de manifestaciones clínicas reumáticas. El compromiso articular incluye las artralgias, la artritis por VIH, el síndrome de Reiter, la artritis psoriásica y la espondiloartropatía indiferenciada. También se ha documentado una miopatía inducida por el VIH en cuyo diagnóstico diferencial se deben tener en cuenta la miopatía inducida por zidovudina y la debida a toxoplasmosis, cuya presentación clínica es más parecida a la miopatía inducida por el VIH que a otras afecciones musculares. El síndrome de linfocitosis con infiltración difusa es una entidad parecida al síndrome de Sjögren, que es exclusiva de los pacientes VIH positivos, con algunas diferencias en la presentación clínica e inmunológica. Por último, es frecuente la presencia de fenómenos autoinmunes el más común de los cuales es la hipergamaglobulinemia policlonal. También se han descrito diferentes tipos de vasculitis como parte de esta enfermedad.

  17. Frecuencia espontánea e inducida de micronúcleos transplacentarios en ratones Balb/c

    Directory of Open Access Journals (Sweden)

    Daniel Francisco Arencibia Arrebola

    2011-01-01

    Full Text Available Introducción: El ensayo de micronúcleos transplacentario, ha sido desarrollado con el objetivo de evaluar el potencial genotóxico en la descendencia y demostrar la capacidad de un agente de causar daños cromosómicos durante el período prenatal. Éste realiza el registro de aberraciones cromosómicas, demostrando si una sustancia determinada puede ser clastogénica o aneugénica en el feto, a través de la exposición materna. Objetivo: Por lo cual en el presente trabajo se tuvo como objetivo determinar la frecuencia espontánea e inducida de micronúcleos transplacentarios en ratones de la línea Balb/c. Pretendiendo vincular de esta forma el efecto genotóxico y reproductivo de una droga a evaluar por esta metodología. Materiales y métodos: Se formaron 4 grupos experimentales, el primero un control negativo (simulacro, el segundo control solvente NaCl (0,9%, en el tercero se utilizo la ciclofosfamida en dosis de 50 mg/kg, y el cuarto se utilizó la bleomicina en dosis de 20 mg/kg. Todos los grupos se administraron por vía intraperitoneal los días 14, 15 y 16 de la gestación y 24 h después de la última inoculación se procedió al sacrificio de las gestantes por dislocación cervical. Obteniéndose las muestras de médula ósea materna e hígado fetal. Resultados: Se obtuvo como resultado los valores espontáneos e inducidos de los índices de citotoxicidad y de genotoxicidad, así como el total de micronúcleos divididos según niveles de daños.Discusión y conclusiones: Se observo mayor inducción de daño en células hepáticas fetales que en médula ósea materna. Además se demostró que la ciclofosfamida es capaz de inducir mayor citotoxicidad y genotoxicidad que la bleomicina tanto en células de la médula ósea materna como en células hepáticas fetales. Por tanto se demostró el poder clastogénico transplacentario de ambos mutágenos vinculando este ensayo de genotoxicidad a la reproducción. Además estos resultados se

  18. Trolox reduces the effect of ethanol on acetylcholine-induced contractions and oxidative stress in the isolated rabbit duodenum El Trolox reduce el efecto del etanol sobre las contracciones inducidas a la acetilcolina y el estrés oxidativo en duodeno aislado de conejo

    Directory of Open Access Journals (Sweden)

    Diego S. Fagundes

    2011-08-01

    Full Text Available Trolox is a hydrophilic analogue of vitamin E and a free radical scavenger. Ethanol diminishes the amplitude of spontaneous contractions and acetylcholine (ACh-induced contractions in rabbit duodenum. The aim of this work was to study the effect of Trolox on the alterations induced by ethanol on contractility and lipid peroxidation in the duodenum. The duodenal contractility studies in vitro were carried out in an organ bath and the levels of malondialdehyde and 4-hydroxyalkenals (MDA+4-HAD were measured by spectrophotometry. Trolox increased the reduction induced by ethanol on the amplitude of spontaneous contractions in longitudinal muscle but not in circular muscle. Trolox 4 mM decreased the effects of ethanol on ACh-induced contractions and on MDA+4-HDA concentrations. We conclude that Trolox might prevent oxidative stress induced by ethanol in the duodenum.El Trolox es un análogo hidrofílico de la vitamina E y un agente que secuestra radicales libres. El etanol disminuye la amplitud de las contracciones espontáneas y las contracciones inducidas a la acetilcolina en el duodeno de conejo. El objetivo de este trabajo era estudiar el efecto del Trolox en las alteraciones inducidas por el etanol sobre la contractilidad y la peroxidación lipídica en el duodeno. Los estudios de contractilidad duodenal in vitro se realizaron en un baño de órganos y los niveles de MDA+4-HDA se midieron por espectofotometría. El Trolox aumentó la reducción inducida por el etanol sobre la amplitud de las contracciones espontáneas en el músculo longitudinal pero no en el músculo circular de duodeno. El Trolox 4 mM redujo los efectos del etanol sobre las contracciones inducidas a la acetilcolina y sobre las concentraciones de MDA+4-HDA. Se concluye que el Trolox podría prevenir el estrés oxidativo inducido por el etanol en el duodeno.

  19. El género afecta las propiedades contráctiles del músculo sóleo en diabetes inducida experimentalmente en ratas

    Directory of Open Access Journals (Sweden)

    Adolfo Virgen Ortiz

    2015-06-01

    Full Text Available Ratas hembras y machos, de tres meses de edad, fueron separados en dos grupos: no diabéticas (ND, peso corporal, 274 ± 9 g; nivel de glucosa en la sangre, 4,94 ± 0,22 mmol/L; n = 16 y diabéticas (D; peso corporal, 207 ± 8 g; nivel de glucosa en sangre, 28,39 ± 0,94 mmol/L; n = 16. La diabetes fue inducida por una sola dosis de 60 mg/Kg de estreptozotocina administrada intraperitonealmente. Las ratas ND recibieron el mismo volumen de vehículo. Después de 4 semanas los animales fueron considerados diabéticos si su nivel de glucosa era ≥ 20 mmol/L. La masa y la contracción del músculo sóleo fueron mayores en machos ND que en las hembras ND. En las ratas macho D disminuyó su masa muscular en un 34% y la fuerza de contracción disminuyó en un 33%; mientras que en las hembras D disminuyeron 15% y 10% respectivamente.

  20. Stray current induced corrosion in lightning rod cables of 525 kV power lines towers: a case study

    Directory of Open Access Journals (Sweden)

    Wojcicki, F. R.

    2003-12-01

    Full Text Available With the growth of several areas in modem society, the necessity to generate and carry electrical energy to big cities has greatly increased. Cables supported by power towers with galvanized steel foundation usually carry energy. As the foundations are underground they may cause high rates of corrosion. These are usually detected by a conventional potential measurement using a Cu/CuSO4 reference electrode. It is believed that corrosion results from stray currents that flow through the ground to close the loop between neighboring towers. Stray currents originate in the lightning rod cables of the power line towers, induced by the strong electromagnetic and electric fields of the energized power lines. The intensity and direction of those currents were measured, indicating substantial values of both their AC and DC components. The potential of the tower ground system, measured in the perpendicular direction of the main axis of the power line, was plotted as a function of the distance to the tower base. The results clearly indicated the tendency to corrosive attack in the anodic towers as reflected by the slope of the plot, whereas no signs of corrosion could be found in the reverse slope, confirming the visual inspection of the foundation. The profile of the potential plots could be changed providing the electric insulation of the lightning rod cable.

    Con el crecimiento de varias áreas en la sociedad moderna, la necesidad de generar y conducir la energía eléctrica a las grandes ciudades ha aumentado enormemente. La energía, normalmente, se transporta por cables sostenidos por torres de energía con base de acero galvanizado. Cuando las bases son subterráneas, pueden ocasionar altas tasas de corrosión. Estas, normalmente, se detectan por la medida convencional del potencial empleando un electrodo de referencia de Cu/CuSO4. Se cree que la corrosión es el resultado de corrientes perdidas que fluyen a través de la

  1. Corrosion Engineering.

    Science.gov (United States)

    White, Charles V.

    A description is provided for a Corrosion and Corrosion Control course offered in the Continuing Engineering Education Program at the General Motors Institute (GMI). GMI is a small cooperative engineering school of approximately 2,000 students who alternate between six-week periods of academic study and six weeks of related work experience in…

  2. Efectos del fMLP y de los antioxidantes sobre funciones inducidas por lipopolisacáridos bacterianos

    OpenAIRE

    Vulcano, Marisa

    1997-01-01

    En el presente tabajo de Tesis se evaluaron las consecuencias de las interacciones de los lipopolisacáridos (LPS) y de los péptidos formilados de las bacterias Gram negativas sobre la activación de distintas funciones celulares involucradas en el desencadenamiento de la respuesta inflamatoria a la infección. En particular, se analizaron los efectos de estos dos componentes bacterianos sobre la activación del estallido respiratorio y la producción de TNF-α en células fagocíticas humanas. Los r...

  3. CARACTERIZACION DE GENES DESHIDRINA EN EUCALYPTUS GLOBULUS CUYA EXPRESION ES INDUCIDA POR LA ACLIMATACION A BAJA TEMPERATURA

    OpenAIRE

    FERNANDEZ REYES, MARTA ALEJANDRA

    2011-01-01

    Eucalyptus globulus es una especie importante para la producción de pulpa de madera en Chile, sin embargo presenta una gran sensibilidad a temperaturas de congelamiento. Durante los últimos años, muchos estudios han enfocado sus esfuerzos en dilucidar los mecanismos que regulan la respuesta de las plantas a baja temperatura, mediante el análisis de la expresión génica. En el presente trabajo se estudia la expresión de genes deshidrina durante el proceso de aclimatación a baja temperatura y...

  4. CARACTERIZACION DE GENES DESHIDRINA EN EUCALYPTUS GLOBULUS CUYA EXPRESION ES INDUCIDA POR LA ACLIMATACION A BAJA TEMPERATURA

    OpenAIRE

    FERNANDEZ REYES ; MARTA ALEJANDRA; FERNANDEZ REYES ; MARTA ALEJANDRA

    2011-01-01

    Eucalyptus globulus es una especie importante para la producción de pulpa de madera en Chile, sin embargo presenta una gran sensibilidad a temperaturas de congelamiento. Durante los últimos años, muchos estudios han enfocado sus esfuerzos en dilucidar los mecanismos que regulan la respuesta de las plantas a baja temperatura, mediante el análisis de la expresión génica. En el presente trabajo se estudia la expresión de genes deshidrina durante el proceso de aclimatación a baja temperatura y la...

  5. Efecto del extracto metanólico de Jatropha macrantha Müll. Arg., en la disfunción eréctil inducida en ratas

    Directory of Open Access Journals (Sweden)

    Aldo Tinco

    2011-07-01

    Full Text Available Objetivos: Determinar el efecto del extracto metanólico de Jatropha macrantha Müll. Arg. ‘huanarpo macho’ en la disfunción eréctil inducida en ratas. Diseño: Experimental. Institución: Laboratorio de Farmacología, Facultad de Medicina, Universidad Nacional Mayor de San Marcos, Lima, Perú; Laboratorio de Farmacia, Universidad Nacional de San Cristóbal de Huamanga, Ayacucho, Perú. Material biológico: Extracto metanólico de Jatropha macrantha Müll Arg. ‘huanarpo macho’; ratas wistar de 300+/-50 g. Intervenciones: La obtención de la muestra se realizó en la Provincia de Vilcas Huamán - Ayacucho. Se evaluó el comportamiento sexual y la concentración de óxido nítrico y el efecto vasorrelajante en el cuerpo cavernoso aislado de pene de ratas, siendo los grupos de estudio: grupo 1 agua 10 mL/kg; grupo 2 sildenafilo 5 mg/kg; grupos 3, 4 y 5 extracto metanólico 100, 200 y 300 mg/kg. Se aisló órganos en los grupos de 50, 100 y 300 ug/mL de extracto, L- arginina 300 uM, acetilcolina 30uM, epinefrina u/mL y sildenafilo (3,2 × 10-5 mg/mL. Principales medidas de resultados: Flavonoides aislados, comportamiento sexual de ratas, niveles plasmáticos de óxido nítrico y relajación del músculo cavernoso. Resultados: Por cromatografía se encontró estructuras tipo flavonas, y mediante espectroscopia UV y reacciones de desplazamiento se identificó 6-hidroxi-4’,5,7-trimetoxi flavona, 4’,7-dihidroxi-5,6-dimetoxiflavona, 7-hidroxi-3’,4’,5’,5,8 pentametoxiflavona, 4’,7-dihidroxi-3’,5,6-trimetoxiflavona, DL50 1357 mg/kg. El comportamiento sexual fue dosis dependiente; la administración de 300 mg/kg de la planta por vía oral incrementó la frecuencia de monta en 75% y elevó los niveles de óxido nítrico en 85%, en tanto que la dosis de 200 mg/kg lo hizo en 71,1% y 32,4%, respectivamente (p<0,05. Conclusiones: En ratas con disfunción eréctil inducida, el extracto metanólico de Jatropha macrantha Müll Arg.

  6. Corrosion in airframes

    OpenAIRE

    PETROVIC ZORAN C.

    2016-01-01

    The introductory chapter provides a brief reference to the issue of corrosion and corrosion damage to aircraft structures. Depending on the nature and dimensions of this non uniformity, three different categories of corrosion are defined: uniform, selective and localized corrosion. The following chapters present the forms of corrosion that can occur in three defined categories of corrosion. Conditions that cause certain types of corrosion in various corrosive environments are discussed. Examp...

  7. Corrosion inhibition

    Energy Technology Data Exchange (ETDEWEB)

    Fisher, A O

    1965-12-29

    An acid corrosion-inhibiting composition consists essentially of a sugar, and an alkali metal salt selected from the group consisting of iodides and bromides. The weight ratio of the sugar to the alkali metal salt is between 2:1 and about 20,000:1. Also, a corrosion- inhibited phosphoric acid composition comprising at least about 20 wt% of phosphoric acid and between about 0.1 wt% and about 10 wt% of molasses, and between about 0.0005 wt% and about 1 wt% of potassium iodide. The weight ratio of molasses to iodide is greater than about 2:1. (11 claims)

  8. Estrés oxidativo y otras respuestas fisiológicas inducidas por el alpeorujo transformado por hongos saprobios en plantas de tomate (Solanum lycopersicum L.)

    OpenAIRE

    García Sánchez, Mercedes

    2013-01-01

    El cultivo del olivar y la obtención industrial de aceite de oliva tienen una extraordinaria importancia económica y social en España y, particularmente, en Andalucía. Actualmente, el sistema de extracción de aceite de oliva es la centrifugación de dos fases tras el que se obtiene una fase oleosa o aceite y un residuo semisólido denominado alpeorujo. Se ha observado, que el alpeorujo presenta un elevado contenido en materia orgánica, nutrientes minerales y un pH ligeramente ácido lo que plant...

  9. Estudio de la influencia de la refrigeracion con aire de forma natural e inducida en el comportamiento de instalaciones fotovoltaicas

    Science.gov (United States)

    Mazon Hernandez, Rocio

    panels are analysed to compare and select the best configuration. The presented research provides a deep knowledge of how they work as well as information and results for an improvement in future designs of building integrated photovoltaic systems. Este estudio se centra en analizar la influencia negativa de la temperatura en la produccion electrica de paneles fotovoltaicos al estar emplazados sobre cubierta de acero, como sucede en naves industriales y sobre un invernadero. Se estudian diferentes configuraciones que permitan refrigerar los paneles, reduciendo su temperatura y mejorar su rendimiento. Para abordar este problema, se han construido dos instalaciones experimentales, fieles a plantas solares en funcionamiento. Una instalacion engloba dos paneles fotovoltaicos sobre estructura fija al suelo. Uno de los paneles esta integrado sobre una superficie paralela y metalica. Entre ambas superficies existe un espacio que posibilita circular aire, permitiendo refrigerar el panel por conveccion natural, o conveccion forzada impulsando el aire con un ventilador. El otro panel, libre por su cara posterior y se ha considerado de referencia. Se ha estudiado el comportamiento del panel integrado sobre cubierta para diferentes secciones de aire y velocidades inducidas, comparandolo con el panel de referencia. Se ha desarrollado un modelo experimental que nos permite determinar la temperatura del panel en funcion de las variables que influyen en su refrigeracion. Adicionalmente, se han analizado los datos de una planta solar en funcionamiento, con paneles de igual caracteristicas, obteniendo correlaciones entre la temperatura del panel y las variables electricas y comparandolos con las obtenidas en la instalacion experimental. La segunda instalacion experimental reproduce parte de una instalacion solar sobre un invernadero, formada por cuatro paneles fotovoltaicos colocados sobre el plastico del invernadero, existiendo un canal divergente entre ambas superficies. Se estudia la

  10. Risk evaluation on internal corrosion of a gas pipeline cut section based on metal mechanic tests and physiochemical analysis of the solids deposited in the pipes; Determinacion del riesgo por corrosion interna de un tramo cortado de una linea de transporte de gas natural a partir de ensayos metalmecanicos y del analisis fisicoquimico de los solidos depositados en la tuberia

    Energy Technology Data Exchange (ETDEWEB)

    Ditta Sarmiento, Johanna Milena [PETROBRAS International (BRASPETRO) (Colombia). Ingenieria de Corrosion DPSU

    2003-07-01

    After inspecting a one of the most important pipelines in Colombia, using intelligent tool, the pipe sections were selected that presented losses of thickness which probably they would be risking integrity of the same one and after, these sections were cut and replaced. To one of the cut sections a study with the objective was made him establish the present forms of corrosion and to determine the phenomena that influenced the presence of the damages. For this study were moderate thicknesses of the wall of the tube and was determined the criticality comparing it with its nominal thickness, according to Standard ASME B - 31G. Taking advantage of the presence solids in the surface, one became both, physical and chemical analysis, DRX and elementary analysis, with the objective to determine its origin and to correlate it with the types of corrosion that were in the line. The morphology that determined were Microbiological Influenced Corrosion, Erosion - Corrosion, Pitting and CO2 corrosion. Then, from all this information the analysis becomes of risks by internal corrosion in pipeline, the plan of mitigation and the plans of monitoring and inspection of the line to avoid the presence of anyone of these forms of corrosion in the future immediate. (author)

  11. Corrosion inhibitors

    International Nuclear Information System (INIS)

    El Ashry, El Sayed H.; El Nemr, Ahmed; Esawy, Sami A.; Ragab, Safaa

    2006-01-01

    The corrosion inhibition efficiencies of some triazole, oxadiazole and thiadiazole derivatives for steel in presence of acidic medium have been studied by using AM1, PM3, MINDO/3 and MNDO semi-empirical SCF molecular orbital methods. Geometric structures, total negative charge on the molecule (TNC), highest occupied molecular energy level (E HOMO ), lowest unoccupied molecular energy level (E LUMO ), core-core repulsion (CCR), dipole moment (μ) and linear solvation energy terms, molecular volume (V i ) and dipolar-polarization (π *), were correlated to corrosion inhibition efficiency. Four equations were proposed to calculate corrosion inhibition efficiency. The agreement with the experimental data was found to be satisfactory; the standard deviations between the calculated and experimental results ranged between ±0.03 and ±4.18. The inhibition efficiency was closely related to orbital energies (E HOMO and E LUMO ) and μ. The correlation between quantum parameters and experimental inhibition efficiency has been validated by single point calculations for the semi-empirical AM1 structures using B3LYP/6-31G** as a higher level of theory. The proposed equations were applied to predict the corrosion inhibition efficiency of some related structures to select molecules of possible activity from a presumable library of compounds

  12. Underground pipeline corrosion

    CERN Document Server

    Orazem, Mark

    2014-01-01

    Underground pipelines transporting liquid petroleum products and natural gas are critical components of civil infrastructure, making corrosion prevention an essential part of asset-protection strategy. Underground Pipeline Corrosion provides a basic understanding of the problems associated with corrosion detection and mitigation, and of the state of the art in corrosion prevention. The topics covered in part one include: basic principles for corrosion in underground pipelines, AC-induced corrosion of underground pipelines, significance of corrosion in onshore oil and gas pipelines, n

  13. Corrosion/95 conference papers

    International Nuclear Information System (INIS)

    Anon.

    1995-01-01

    The papers in this conference represent the latest technological advances in corrosion control and prevention. The following subject areas are covered: cathodic protection in natural waters; materials for fossil fuel combustion and conversion systems; modern problems in atmospheric corrosion; innovative ideas for controlling the decaying infrastructure; deposits and their effects on corrosion in industry; volatile high temperature and non aqueous corrosion inhibitors; corrosion of light-weight and precoated metals for automotive application; refining industry corrosion; corrosion in pulp and paper industry; arctic/cold weather corrosion; materials selection for waste incinerators and associated equipment; corrosion measurement technology; environmental cracking of materials; advancing technology in the coating industry; corrosion in gas treating; green inhibition; recent advances in corrosion control of rail equipment; velocity effects and erosion corrosion in oil and gas production; marine corrosion; corrosion of materials in nuclear systems; underground corrosion control; corrosion in potable and industrial water systems in buildings and its impact on environmental compliance; deposit related boiler tube failures; boiler systems monitoring and control; recent developments and experiences in reactive metals; microbiologically influenced corrosion; corrosion and corrosion control for steel reinforced concrete; international symposium on the use of 12 and 13 Cr stainless steels in oil and gas production environments; subsea corrosion /erosion monitoring in production facilities; fiberglass reinforced pipe and tubulars in oilfield service; corrosion control technology in power transmission and distribution; mechanisms and methods of scale and deposit control; closing the loop -- results oriented cooling system monitoring and control; and minimization of aqueous discharge

  14. Comportamiento de la corrosión de aleaciones de magnesio AZ31-B en ambiente marino, modificadas por el proceso de fricción-agitación Corrosion behavior in marine environment of magnesium alloy AZ31-B welded by friction-agitation process

    Directory of Open Access Journals (Sweden)

    Willian Aperador Chaparro

    2012-04-01

    Full Text Available En el presente artículo se estudia el comportamiento de la corrosión de la aleación de magnesio AZ31-B en ambiente marino simulado, modificada mediante el proceso de fricción-agitación (PFA, con el fin de determinar el efecto de las variables del proceso, velocidad de rotación y velocidad de avance. Se llevaron a cabo análisis mediante espectroscopia de impedancia electroquímica y curvas de polarización potencio-dinámicas (Tafel. Adicionalmente, se determinó la microestructura en las zonas del cordón de soldadura a través de metalografía óptica. Finalmente, se analizaron los productos de corrosión formados en la superficie de las muestras por medio del microscopio electrónico de barrido (SEM equipado con el analizador químico por EDS. Se observó que una relación de velocidad de avance/velocidad de rotación mayor produce menor velocidad de corrosión y con ello mayor resistencia a la corrosión en medios salinos, al parecer relacionados con el gran tamaño de grano en la zona agitada, que corresponde a más entrada de calor.The corrosion behavior of AZ31B magnesium alloy modified by friction stir processing (FSP was studied in simulated marine environment, in order to determine the effect of process variables rotation speed and travel speed. The corrosion analysis was carried upon by means of electrochemical impedance spectroscopy and potentiodynamic polarization curves (Tafel, metallographic analysis of the welded zones was done by optical microscopy and the chemical analysis of the corrosion products were done by using scanning electron microscope (SEM, equipped with EDS analyzer. It was observed that the increase of the rate rotation speed/travel speed of the process produces a decrease in the corrosion rate and the corresponding increase of the corrosion resistance in marine environment, apparently related to the higher grain size found in the stir zone, corresponding to a higher heat input.

  15. Investigation of the corrosion resistance of Ti-13Nb-13Zr alloy by electrochemical techniques and surface analysis; Investigacao da resistencia a corrosao da liga Ti-13Nb-13Zr por meio de tecnicas eletroquimicas e de analise de superficie

    Energy Technology Data Exchange (ETDEWEB)

    Assis, Sergio Luiz de

    2006-07-01

    In this work, the in vitro corrosion resistance of the Ti-13Nb-13Zr alloy, manufactured at a national laboratory, and used for orthopedic applications, has been investigated in solutions that simulate the body fluids. The electrolytes used were 0.9 % (mass) NaCl, Hanks' solution, a culture medium (MEM), and the two last electrolytes, without and with addition of hydrogen peroxide. The aim of peroxide addition was to simulate the conditions found when inflammatory reactions occur due to surgical procedures. The corrosion resistance of alloys commercially in use as biomaterials, Ti-6Al-7Nb and Ti-6Al-4V, as well as of the pure titanium (Ti-cp), was also studied for comparison with the Ti-13Nb-13Zr alloy. The corrosion resistance characterization was carried out by electrochemical and surface analysis techniques. The electrochemical tests used were: open circuit potential measurements as a function of tim; potentiodynamic polarization; and electrochemical impedance spectroscopy (EIE). The impedance experimental diagrams were interpreted using equivalent electric circuits that simulate an oxide film with a duplex structure composed of an internal and compact, barrier type layer, and an external porous layer. The results showed that the corrosion resistance is due mainly to the barrier type layer. The titanium alloys and the Ti-cp showed high corrosion resistance in all electrolytes used. The oxides formed on the Ti-13Nb-13Zr, either naturally or during immersion in MEM ar Hank's solution was characterized by X-ray photoelectron spectroscopy (XPS) and scanning electron microscopy (MEV). The results showed that the presence of hydrogen peroxide in MEM promotes the growth of the porous layer and incorporation of mineral ions, besides favouring hydroxyapatite formation. The cytotoxicity of the Ti-13Nb-13Zr alloy was also evaluated and it was shown to be non-toxic. (author)

  16. Investigation of the corrosion resistance of Ti-13Nb-13Zr alloy by electrochemical techniques and surface analysis; Investigacao da resistencia a corrosao da liga Ti-13Nb-13Zr por meio de tecnicas eletroquimicas e de analise de superficie

    Energy Technology Data Exchange (ETDEWEB)

    Assis, Sergio Luiz de

    2006-07-01

    In this work, the in vitro corrosion resistance of the Ti-13Nb-13Zr alloy, manufactured at a national laboratory, and used for orthopedic applications, has been investigated in solutions that simulate the body fluids. The electrolytes used were 0.9 % (mass) NaCl, Hanks' solution, a culture medium (MEM), and the two last electrolytes, without and with addition of hydrogen peroxide. The aim of peroxide addition was to simulate the conditions found when inflammatory reactions occur due to surgical procedures. The corrosion resistance of alloys commercially in use as biomaterials, Ti-6Al-7Nb and Ti-6Al-4V, as well as of the pure titanium (Ti-cp), was also studied for comparison with the Ti-13Nb-13Zr alloy. The corrosion resistance characterization was carried out by electrochemical and surface analysis techniques. The electrochemical tests used were: open circuit potential measurements as a function of tim; potentiodynamic polarization; and electrochemical impedance spectroscopy (EIE). The impedance experimental diagrams were interpreted using equivalent electric circuits that simulate an oxide film with a duplex structure composed of an internal and compact, barrier type layer, and an external porous layer. The results showed that the corrosion resistance is due mainly to the barrier type layer. The titanium alloys and the Ti-cp showed high corrosion resistance in all electrolytes used. The oxides formed on the Ti-13Nb-13Zr, either naturally or during immersion in MEM ar Hank's solution was characterized by X-ray photoelectron spectroscopy (XPS) and scanning electron microscopy (MEV). The results showed that the presence of hydrogen peroxide in MEM promotes the growth of the porous layer and incorporation of mineral ions, besides favouring hydroxyapatite formation. The cytotoxicity of the Ti-13Nb-13Zr alloy was also evaluated and it was shown to be non-toxic. (author)

  17. Aircraft Corrosion

    Science.gov (United States)

    1981-08-01

    attribud au choix de traitements et de rev~tements spproprids. Au contrairo, dens d’sutros structures des corrosions iirportsntea se sont msnifestdes...au traitement . micaniqus qui provoque une compression de surface - h1l’spplication i1’une double protection comportant oxydation snodique et...chlore mais dans une proportion semblable b cells d’une eau de vil)e ; - lea solides, d’aprbs lea analyses chimique et criatallographique, paraissaiont

  18. Corrosion Testing Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Corrosion Testing Facility is part of the Army Corrosion Office (ACO). It is a fully functional atmospheric exposure site, called the Corrosion Instrumented Test...

  19. Efecto terapéutico del extracto etanólico de Erythroxylum coca spp. en anemia ferropénica inducida en ratas Holtzman macho

    Directory of Open Access Journals (Sweden)

    Evelyn F. Gonzales-Carazas

    2013-01-01

    Full Text Available Introducción: La hoja de coca ha sido usada tradicionalmente con fines medicinales y contiene altos niveles de hierro. Objetivos: Determinar el efecto del extracto etanólico de Erythroxylum coca spp. frente a anemia ferropénica inducida por dieta deficiente en hierro, en ratas Holtzman macho. Diseño: Experimental. Lugar: Laboratorio del Instituto de Patología, Facultad de Medicina, Universidad Nacional Mayor de San Marcos. Material biológico: Dieciocho ratas Holtzman macho de 16 días de edad recién destetadas. Intervenciones: Se formó tres grupos de seis ratas cada uno: a grupo hierro suficiente (HS, recibió 25 g/d de alimento balanceado durante 7 semanas; b grupo hierro deficiente (HD, recibió 25 g/d de dieta ferropénica durante 7 semanas; y, c el grupo hierro deficiente - extracto E. coca (HD-EC, recibió 25 g/d de dieta ferropénica durante 7 semanas y a partir de la semana 5 se agregó 18 g/d de extracto de E. coca. Principales medidas de resultados: Nivel sérico de hemoglobina, peso y talla. Resultados: Al finalizar el tratamiento, se observó aumento significativo de la hemoglobina en el grupo HD-EC (p=0,04. Se encontró diferencia significativa en los niveles séricos de hemoglobina entre los grupos HD-EC y HD (p=0,0062. No se encontró diferencia significativa en los valores de hemoglobina entre los grupos HD-EC y HS (p= 0,06. No se evidenció diferencia en el peso y la talla entre los grupos HD y HD-EC (p=0,20 y p=0,23, respectivamente. Conclusiones: E. coca presenta efecto antianémico experimental, sustentado en los resultados de los niveles de hemoglobina.

  20. Corrosion technology. V. 1

    International Nuclear Information System (INIS)

    Khan, I.H.

    1989-01-01

    This book has been produced for dissemination of information on corrosion technology, corrosion hazards and its control. Chapter one of this book presents an overall view of the subject and chapter 2-5 deals with electrochemical basics, types of corrosion, pourbaix diagrams and form of corrosion. The author explains polarization/kinetics of corrosion, passivity, aqueous corrosion and corrosion testing and monitoring in 6-11 chapters. The author hopes it will provide incentive to all those interested in the corrosion technology. (A.B.)

  1. Corrosion/94 conference papers

    International Nuclear Information System (INIS)

    Anon.

    1994-01-01

    The approximately 500 papers from this conference are divided into the following sections: Rail transit systems--stray current corrosion problems and control; Total quality in the coatings industry; Deterioration mechanisms of alloys at high temperatures--prevention and remediation; Research needs and new developments in oxygen scavengers; Computers in corrosion control--knowledge based system; Corrosion and corrosivity sensors; Corrosion and corrosion control of steel reinforced concrete structures; Microbiologically influenced corrosion; Practical applications in mitigating CO 2 corrosion; Mineral scale deposit control in oilfield-related operations; Corrosion of materials in nuclear systems; Testing nonmetallics for life prediction; Refinery industry corrosion; Underground corrosion control; Mechanisms and applications of deposit and scale control additives; Corrosion in power transmission and distribution systems; Corrosion inhibitor testing and field application in oil and gas systems; Decontamination technology; Ozone in cooling water applications, testing, and mechanisms; Corrosion of water and sewage treatment, collection, and distribution systems; Environmental cracking of materials; Metallurgy of oil and gas field equipment; Corrosion measurement technology; Duplex stainless steels in the chemical process industries; Corrosion in the pulp and paper industry; Advances in cooling water treatment; Marine corrosion; Performance of materials in environments applicable to fossil energy systems; Environmental degradation of and methods of protection for military and aerospace materials; Rail equipment corrosion; Cathodic protection in natural waters; Characterization of air pollution control system environments; and Deposit-related problems in industrial boilers. Papers have been processed separately for inclusion on the data base

  2. Characterization and corrosion behavior of phytic acid coatings, obtained by chemical conversion on magnesium substrates in physiological solution; Caracterizacion y comportamiento frente a la corrosion de recubrimientos de acido fitico, obtenidos por conversion quimica, sobre substratos de magnesio en solucion fisiologica

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez-Alvarado, L. A.; Lomeli, M. A.; Hernandez, L. S.; Miranda, J. M.; Narvaez, L.; Diaz, I.; Garcia-Alonso, M. C.; Escudero, M. L.

    2014-10-01

    In order to improve the corrosion resistance of biodegradable magnesium and AZ31 magnesium alloy implants, a phytic acid coating has been applied on both substrates and their protective effect against corrosion has been assessed. The morphology and the chemical nature of the conversion coating were analyzed by SEM/EDX, XRD and FTIR. The spectra showed that the conversion coating was amorphous, and it was composed of Mg, O, and P on magnesium surface, along with Al, Zn and C on AZ31 alloy. The main coating components were chelate compounds formed by phytic acid and metallic ions. The corrosion resistance of bare and coated samples was evaluated by potentiodynamic polarization technique in Hank's solution at 37 degree centigrade. The results indicate that phytic acid conversion coatings provided a very effective protection to the magnesium substrates studied. (Author)

  3. Evaluation of the susceptibility to corrosion by pites of supermartensitic stainless steel with different superficial finishing; Avaliacao da susceptibilidade a corrosao por pites do aco inoxidavel supermartensitico com diferentes acabamentos superficiais

    Energy Technology Data Exchange (ETDEWEB)

    Freitas, Mario Jose Bueno de Souza

    2015-07-01

    The objective of this study is to evaluate the susceptibility by pitting corrosion in a supermartensitic stainless steel (13%Cr) with different surface finishes, in an environment that simulates the conditions found in the range of the Brazilian marine subsoil before the dense layer of salt - the so-called pre-salt. In this study were conducted electrochemical tests of potentiodynamic anodic polarization and electrochemical impedance spectroscopy (EIS) in environment containing 35, 50 and 190 g/L of NaCl and dissolved oxygen concentrations <10, 100 and 500ppb. Were also used the techniques of Moessbauer spectroscopy and EDS (Energy Dispersive Spectrometry) coupled to a scanning electron microscope (SEM) for microstructural characterization of 13%Cr steel. It was observed by the electrochemical tests, the increase in the concentration of chloride ions in solution makes the studied steel more susceptible to localized corrosion. It was also observed that the material showed less susceptibility to pitting corrosion when its surface was less rough. (author)

  4. Accelerated Corrosion Testing

    Science.gov (United States)

    1982-12-01

    Treaty Organization, Brussels, 1971), p. 449. 14. D. 0. Sprowls, T. J. Summerson, G. M. Ugianski, S. G. Epstein, and H. L. Craig , Jr., in Stress...National Association of Corrosion Engineers Houston, TX, 1972). 22. H. L. Craig , Jr. (ed.), Stress Corrosion-New Approaches, ASTM-STP- 610 (American...62. M. Hishida and H. Nakada, Corrosion 33 (11) 403 (1977). b3. D. C. Deegan and B. E. Wilde, Corrosion 34 (6), 19 (1978). 64. S. Orman, Corrosion Sci

  5. Corrosion/96 conference papers

    International Nuclear Information System (INIS)

    Anon.

    1996-01-01

    Topics covered by this conference include: cathodic protection in natural waters; cleaning and repassivation of building HVAC systems; worldwide opportunities in flue gas desulfurization; advancements in materials technology for use in oil and gas service; fossil fuel combustion and conversion; technology of corrosion inhibitors; computers in corrosion control--modeling and information processing; recent experiences and advances of austenitic alloys; managing corrosion with plastics; corrosion measurement technology; corrosion inhibitors for concrete; refining industry; advances in corrosion control for rail and tank trailer equipment; CO 2 corrosion--mechanisms and control; microbiologically influenced corrosion; corrosion in nuclear systems; role of corrosion in boiler failures; effects of water reuse on monitoring and control technology in cooling water applications; methods and mechanisms of scale and deposit control; corrosion detection in petroleum production lines; underground corrosion control; environmental cracking--relating laboratory results and field behavior; corrosion control in reinforced concrete structures; corrosion and its control in aerospace and military hardware; injection and process addition facilities; progress reports on the results of reinspection of deaerators inspected or repaired per RP0590 criteria; near 100% volume solids coating technology and application methods; materials performance in high temperature environments containing halides; impact of toxicity studies on use of corrosion/scale inhibitors; mineral scale deposit control in oilfield related operations; corrosion in gas treating; marine corrosion; cold climate corrosion; corrosion in the pulp and paper industry; gaseous chlorine alternatives in cooling water systems; practical applications of ozone in recirculating cooling water systems; and water reuse in industry. Over 400 papers from this conference have been processed separately for inclusion on the data base

  6. Evaluation and mitigation of the degradation by corrosion in the components of the service water system of a nuclear power plant; Evaluacion y mitigacion de la degradacion por corrosion en los componentes del sistema de agua de servicio de una planta nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Salaices A, E.; Salaices, M.; Ovando, R. [IIE, Av. Reforma 113 Col. Palmira, 62490 Cuernavaca, Morelos (Mexico)]. e-mail: sal@iie.org.mx

    2005-07-01

    One of the main problems that face the nuclear power stations is the degradation by corrosion in the service water systems. The corrosion causes lost substantial in energy generation and a high cost in maintenance and repairs. In this work, the results of a study of the degradation by the MIC mechanisms (microorganisms influenced corrosion), incrustations in heat exchangers and erosion for solid particles in the components of a typical service water system of a nuclear plant are presented. Diverse mitigation options are analyzed for these mechanisms. In the analysis, it was used the CHECWORKS-CWA code to carry out the evaluation of the degradation so much as well as the mitigation of the caused damage. The results are presented in susceptibility indexes and degradation rates component-by-component. A significant decrement could be observed in the susceptibility to MIC when changing the operation conditions of stagnated flow to continuous flow. With respect to the erosion by solid particles, it was found a significant reduction of the damage it when adding filters to the system. Finally, in the case of the heat exchangers, it is shown that one of the more viable options to diminish incrustations and existent calcium deposits it is the reduction of the pH of the service water. (Author)

  7. Estudo das características de revestimentos poliméricos aplicados por aspersão térmica para proteção contra desgaste e corrosão de substratos metálicos Study of the characteristics of thermally sprayed polymer coatings for wear and corrosion protection of metallic substrates

    Directory of Open Access Journals (Sweden)

    Carlos Roberto Camello Lima

    2012-12-01

    Full Text Available Revestimentos poliméricos vêm sendo crescentemente considerados como solução na proteção de materiais metálicos contra corrosão e desgaste. A tecnologia de aspersão térmica permite a aplicação de polímeros sobre diversos materiais de substrato, em diversas espessuras, para várias condições ambientais. Polímeros depositados por este processo têm potencial, tanto para reduzir custos com materiais, como para melhorar o desempenho do revestimento em ambientes agressivos. Neste trabalho, foram aplicados revestimentos poliméricos poli-éter-éter-cetona (PEEK e Poliamida 12 sobre substratos de aço carbono, utilizando o processo de aspersão térmica a chama de baixa velocidade. Revestimentos de alta qualidade foram obtidos por esta técnica. Foram avaliadas as características dos materiais e dos revestimentos obtidos, especialmente quanto às propriedades mecânicas, de desgaste e corrosão. De acordo com os resultados obtidos, pode-se afirmar que os revestimentos estudados podem ser utilizados com sucesso em aplicações que envolvam desgaste e corrosão, com uma pequena vantagem para o polímero PEEK.Polymer coatings have been widely considered as a solution in the protection of metallic substrates against both wear and corrosion. Thermal spray technology allows the deposition of polymers onto several substrate materials for various thicknesses at several environmental conditions. Thermal sprayed polymers have high potential for material cost reduction as well as to improve coating performance in drastic environments. In this work, poly-ether-ether-ketone (PEEK and Polyamide 12 were flame sprayed on carbon steel substrates. High quality coatings were obtained. Several tests were carried out to evaluate the coatings mainly related to wear and corrosion performance. According to the obtained results, it can be stated that the studied coatings can be successfully used in applications involving wear and corrosion, with a slight edge

  8. Rehabilitation of the gas pipeline that had a rupture in service caused by SCC (Stress Corrosion C raking); Rehabilitacion al servicio de un gasoducto que ha sufrido una ruptura en servicio por SCC

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Fernando; Carzoglio, Eduardo; Hryciuk, Pedro [TGN - Transportadora de Gas del Norte S.A. (Argentina). Depto. de Integridad

    2003-07-01

    TGN had a rupture in service on Gasoducto Troncal Norte. After initial evaluation of the causes of the rupture it was concluded that it had been caused by Stress Corrosion Cracking (SCC). Subsequent investigation in the area of the rupture revealed that colonies of cracks, typical of SCC were found in pipes located near the rupture. In order to put back in service the pipeline in a safety condition, SCC mitigation activities were performed. A decision was made to conduct a hydro test along approximately 30 kilometers of pipe. The stages of the works, the problems faced and the solutions found are dealt with, as well as the conclusions reached upon completion of the works which allowed a better understanding of SCC phenomenon. The methodology for the identification of those areas susceptible to SCC is also described. (author)

  9. Modelación con elementos finitos del agrietamiento en el hormigón por corrosión localizada en la armadura Finite element modeling of cracking in concrete due to localized corrosion in the reinforcement

    Directory of Open Access Journals (Sweden)

    J Castorena

    2007-04-01

    Full Text Available En base a estudios con elemento finito, en el presente trabajo se obtiene un modelo capaz de predecir la cantidad de acero corroído (rcrit en la armadura necesaria para que aparezca la primera grieta visible en la superficie del recubrimiento del hormigón. Para el análisis con elemento finito se utiliza el software ANSYS, el cual dispone del elemento SOLID65, con el que es posible modelar el hormigón simple, ya que tiene la capacidad de sufrir aplastamiento en compresión y agrietarse a tracción. El caso de la capa de óxido es modelado mediante elementos de contacto CONTA174, y la armadura con SOLID65, pero sin las opciones de aplastamiento y agrietamiento. El modelo obtenido está en función del recubrimiento libre, diámetro del refuerzo, tipo de hormigón y la longitud corroída, denominada ésta longitud anódica. Los resultados muestran la gran influencia que tiene la corrosión localizada (longitud anódica pequeña-longitud catódica grande sobre el cálculo de rcrit, y que dicho efecto sólo es posible analizarlo de manera tridimensional. Así mismo, se muestra la eficiencia de utilizar los elementos de contacto CONTA174 para representar el crecimiento de óxidos. El modelo obtenido explica en un 92% el fenómeno y se compara con resultados experimentales encontrados en la literaturaBased on studies with finite element method, a model able to predict the quantity of steel corrosion (rcrit necessary for the first visible crack appearance in the surface of the concrete cover was obtained. For the finite element analysis the software ANSYS was used, which has the element SOLID65, with which is possible to model plain concrete, since has the capacity to show crushing in compression and to cracking in tension. The case of the oxide layer is modeled by means of contact elements CONTA174 and the steel with SOLID65, but without the crushing and cracking options. The obtained model is in function of the free cover, diameter of the

  10. Effect of rofecoxib on colon chemical carcinogenesis at colonic anastomotic area in the rat Influencia del rofecoxib en la carcinogénesis cólica perianastomótica inducida en ratas

    Directory of Open Access Journals (Sweden)

    J. F. Noguera Aguilar

    2005-06-01

    durante 18 semanas y se analizaron los tumores cólicos inducidos en la semana 20 del postoperatorio. El principal parámetro evaluado fue el porcentaje de tejido cólico neoplásico, que relaciona la superficie tumoral con la superficie del colon. Resultados: el rofecoxib a dosis de 0,0058 ppm redujo significativamente la carcinogénesis cólica inducida en ratas, tanto a nivel perianastomótico como en el resto del colon (p < 0,01. A nivel extraanastomótico, el rofecoxib a dosis de 2,5 mg/kg fue significativamente superior en su efecto inhibidor al rofecoxib a dosis de 1,2 mg/kg o 0,0027 ppm (p < 0,005. Conclusiones: el rofecoxib produce una disminución en la carcinogénesis cólica farmacológicamente inducida en ratas. Este efecto se mantiene en el área perianastomótica, por lo que puede ser interesante investigar su implicación en el cáncer colorrectal intervenido con riesgo de recidiva locorregional.

  11. Les activités de gestion d’alerte épidémiologique : les transformations induites par l’utilisation d’un système de surveillance en temps réel Alert Management Activity: Cognitive and team activity modifications due to the use of an early warning system Las actividades de gestión de alerta epidemiológica : las transformaciones inducidas por la utilización de un sistema de vigilancia en tiempo real

    Directory of Open Access Journals (Sweden)

    Charlotte Gaudin

    2012-05-01

    dinámico puesto que las epidemias evolucionan y se propagan rápidamente si ninguna acción es emprendida para controlarlas. Más precisamente dos tipos de situaciones son analizadas : (1 la actividad tradicional de gestión de alerta y (2 esta misma actividad cuando es asistida por un sistema informático, en el caso el sistema ASTER (o Alerta y Supervisión en Tiempo Real. Luego, los resultados obtenidos son discutidos a nivel cognitivo y a nivel de las actividades colectivas consecutivamente a la introducción y a la utilización de un sistema técnico.

  12. Catastrophes caused by corrosion

    OpenAIRE

    PETROVIC ZORAN C.

    2016-01-01

    For many years, huge attention has been paid to the problem of corrosion damage and destruction of metallic materials. Experience shows that failures due to corrosion problems are very important, and statistics at the world level shows that the damage resulting from the effects of various forms of corrosion is substantial and that, for example, in industrialized countries it reaches 4-5% of national incomes. Significant funds are determined annually for the prevention and control of corrosion...

  13. Modelling of Corrosion Cracks

    DEFF Research Database (Denmark)

    Thoft-Christensen, Palle

    Modelling of corrosion cracking of reinforced concrete structures is complicated as a great number of uncertain factors are involved. To get a reliable modelling a physical and mechanical understanding of the process behind corrosion in needed.......Modelling of corrosion cracking of reinforced concrete structures is complicated as a great number of uncertain factors are involved. To get a reliable modelling a physical and mechanical understanding of the process behind corrosion in needed....

  14. Evaluation of the susceptibility to pitting corrosion of steel api 5L x42 exposed to solutions containing chloride ions and CO{sub 2} by electrochemical noise measurements; Evaluacion de la susceptibilidad a la corrosion por picado del acero api 5l x42 expuesto a un ambiente con cloruros y CO{sub 2} mediante la tecnica de ruido electroquimico

    Energy Technology Data Exchange (ETDEWEB)

    Pena-Ballesteros, D.; Rodriguez-Vanegas, N.; Anteliz, C.; Sarmiento Klapper, H.

    2011-07-01

    The concentration of chloride ions and the partial pressure of CO{sub 2} play an important role in the degradation of low-carbon steels used for the construction of pipelines in oil and gas industry. In order to evaluate the susceptibility of carbon steel API 5L X42 to pitting corrosion electrochemical noise and linear polarization resistance measurements were carried out in aqueous solutions containing chloride ions and CO{sub 2}. The concentration of chloride ions was varied between, 10000 and 18000 ppm, and the CO{sub 2} partial pressure between 10 psi and 18 psi. Experimental results pointed out that the formation of protective layer, consisting mainly of FeCO{sub 3}, depends on the partial pressure of CO{sub 2} in the system. Nevertheless, the stability of this layer was considerably affected by increasing the concentration of chloride ions causing that localized corrosion has taken place in some areas of the surface of API 5L X42, which were detected by electrochemical noise technique. (Author) 10 refs.

  15. EFECTO DE Tropaeolum tuberosum FRENTE A LA HIPERPLASIA PROSTÁTICA BENIGNA INDUCIDA EN RATAS HOLTZMAN

    Directory of Open Access Journals (Sweden)

    Gioliana Aire-Artezano

    2013-01-01

    Full Text Available Objetivo: Evaluar el efecto de Tropaeolum tuberosum(mashua frente a la Hiperplasia Prostática Benigna (HPB y compararlo con finasterida. Métodos: Estudio experimental completo. Se emplearon 30 ratas Holtzman macho de 12 semanas de edad, aleatorizadas y divididas en seis gru- pos: grupo blanco; grupo testosterona; grupo finasterida (0.33mg/kg/rata; y tres grupos dosis, dosis 1 (300mg/kg/rata, dosis 2 (500mg/kg/rata y dosis 3 (800mg/kg/rata tratados con Tropaeolum tuberosum. Se realizó una medición basal del volumen prostático mediante una ecografía transabdominal. La inducción de HPB se realizó con enantato de testosterona (0,083mg/Kg/rata en los grupos dosis, finasterida y testosterona, el día uno y siete. Paralelamente, se administró liofilizado de Tropaeolum tuberosum y finasterida durante 21 días. Para el diagnóstico, se realiza- ron estudios por imágenes, anatomopatológicos e histopatológicos. Resultados: El estudio por imágenes, en relación al incremento del volumen prostático,no arrojó diferencia significativa entre dosis 2 y finasterida; mientras que en relación con la ecogenicidad, dosis 3 presentó similitud cualitativa al finasterida. En el estudio anatomopatológico, no hubo diferencia significativa entre el grupo dosis 3 y el grupo finasterida. Histo- patológicamente, dosis 3 se asemejó cuantitativamente al finasterida. Conclusiones: Se evidenció disminución de la HPB histológicamente y en el estudio por imágenes; sin embargo, ninguna de las dosis mostró efecto superior al finasterida.

  16. Erosion-corrosion

    International Nuclear Information System (INIS)

    Aghili, B.

    1999-05-01

    A literature study on erosion-corrosion of pipings in the nuclear industry was performed. Occurred incidents are reviewed, and the mechanism driving the erosion-corrosion is described. Factors that influence the effect in negative or positive direction are treated, as well as programs for control and inspection. Finally, examples of failures from databases on erosion-corrosion are given in an attachment

  17. Microbiological corrosion of metals

    International Nuclear Information System (INIS)

    Vladislavlev, V.V.

    1992-01-01

    Problems is considered of development of the microbiological corrosion of the NPP equipment. The main attention is paid to the selective character of microbiological corrosion in zones of welded joints of austenitic steels. It is noted that the presence of technological defects promotes growth of corrosional damages. Methods for microbiological corrosion protection are discussed

  18. Management of Reinforcement Corrosion

    DEFF Research Database (Denmark)

    Küter, André; Geiker, Mette Rica; Møller, Per

    Reinforcement corrosion is the most important cause for deterioration of reinforced concrete structures, both with regard to costs and consequences. Thermodynamically consistent descriptions of corrosion mechanisms are expected to allow the development of innovative concepts for the management...... of reinforcement corrosion....

  19. Compuestos fenólicos de la fracción metanólica de Bidens pilosa, sobre la neoplasia gástrica, inducida en ratas

    Directory of Open Access Journals (Sweden)

    Jorge Arroyo

    2007-06-01

    Full Text Available Objetivo: Determinar la influencia del extracto etanólico y la fracción metanólica conteniendo compuestos fenólicos y flavonoides de la planta entera de Bidens pilosa L sobre la neoplasia gástrica inducida en ratas con N-nitroso-N-metilurea (NMU. Diseño: Experimental. Lugar: Instituto de Investigaciones Clínicas-Bioterio Facultad de Medicina UNMSM. Material biológico: Ratas albinas cepa Holtzmann machos. Intervenciones: Según Ferraz de Souza y col., 2002, se dispuso de un grupo control normal, un grupo con NMU y grupos de NMU más tratamientos de extracto etanólico y fracción metanólica, a dosis de 300 mg/kg. Para la significancia estadística se consideró la p<0,05. Principales medidas de resultados: Progresión de la neoplasia gástrica inducida en ratas. Resultados: Indican displasia y estadios iniciales de carcinoma en los estómagos de las ratas, lo que fue menos evidente en los animales con tratamiento, siendo mejor el grupo que recibió fracción metanólica. El marcador de estrés oxidativo disminuyó en los grupos que recibieron tratamiento con la planta, resultando mejor la fracción metabólica. Se observó menor cantidad de micronúcleos (genotoxicidad en los animales que recibieron tratamiento. Conclusiones: El extracto etanólico y la fracción metanólica de Bidens pilosa L en las condiciones experimentales han detenido la progresión de la neoplasia gástrica inducida en ratas.

  20. Carbonatogénesis inducida en un perfil de suelo tropical

    Directory of Open Access Journals (Sweden)

    Yamile Valencia González

    2014-01-01

    Full Text Available En los suelos puede generarse un proceso común en la naturaleza denominado “biomineralización”o “bioprecipitación”, mediante el cual los organismos vivos presentes en él forman precipitados minerales cristalinos o amorfos. Este proceso es muy importante para la ingeniería geotécnica, ya que los minerales precipitados pueden llenar los vacíos o ligar las partículas de suelo mejorando las propiedades geológico-geotécnicas del material; sin embargo, el proceso demora muchísimos años para ocurrir de forma natural. Es por eso, que con esta investigación se buscó inducir en pocos días (15 días la precipitación de minerales de carbonato de calcio, a partir de la adición de un nutriente precipitador sobre las bacterias nativas existentes en un perfil de suelo tropical, mejorando sus propiedades ingenieriles por medio de la disminución del índice de vacíos, la retracción, la permeabilidad, el colapso, la erodabilidad y la degradación, y del aumento de la cohesión y la fricción, causando menor impacto ambiental que otras técnicas usadas comúnmente en la ingeniería.

  1. Corrosion of metallic materials. Dry corrosion, aqueous corrosion and corrosion by liquid metal, methods of protection

    International Nuclear Information System (INIS)

    Helie, Max

    2015-01-01

    This book is based on a course on materials given in an engineering school. The author first gives an overview of metallurgy issues: metallic materials (pure metals, metallic alloys), defects of crystal lattices (point defects, linear defects or dislocations), equilibrium diagrams, steels and cast, thermal processing of steels, stainless steels, aluminium and its alloys, copper and its alloys. The second part addresses the properties and characterization of surfaces and interfaces: singularity of a metal surface, surface energy of a metal, energy of grain boundaries, adsorption at a material surface, metal-electrolyte interface, surface oxide-electrolyte interface, techniques of surface analysis. The third chapter addresses the electrochemical aspects of corrosion: description of the corrosion phenomenon, free enthalpy of a compound and free enthalpy of a reaction, case of dry corrosion (thermodynamic aspect, Ellingham diagram, oxidation mechanisms, experimental study, macroscopic modelling), case of aqueous corrosion (electrochemical thermodynamics and kinetics, experimental determination of corrosion rate). The fourth part addresses the different forms of aqueous corrosion: generalized corrosion (atmospheric corrosion, mechanisms and tests), localized corrosion (galvanic, pitting, cracking, intergranular, erosion and cavitation), particular cases of stress cracking (stress corrosion, fatigue-corrosion, embrittlement by hydrogen), and bi-corrosion (of non alloyed steels, of stainless steels, and of aluminium and copper alloys). The sixth chapter addresses the struggle and the protection against aqueous corrosion: methods of prevention, scope of use of main alloys, geometry-based protection of pieces, use of corrosion inhibitors, use of organic or metallic coatings, electrochemical protection. The last chapter proposes an overview of corrosion types in industrial practices: in the automotive industry, in the oil industry, in the aircraft industry, and in the

  2. Nutrición parenteral total en una paciente gestante con pancreatitis aguda e hipertrigliceridemia por déficit de lipoproteín lipasa

    OpenAIRE

    Contreras-Bolívar, Victoria; González-Molero, Inmaculada; Valdivieso, Pedro; Olveira, Gabriel

    2015-01-01

    Presentamos un caso de pancreatitis aguda severa inducida por hipertrigliceridemia secundaria a déficit de lipoproteín lipasa (LPL) en una paciente gestante con diabetes gestacional, manejada inicialmente con dieta, siendo necesario posteriormente llevar a cabo medidas de soporte nutricional artificial: nutrición parenteral total. El déficit de LPL causa hipertrigliceridemia severa y, frecuentemente, pancreatitis aguda de repetición, situación de difícil manejo y de importante gravedad durant...

  3. Fighting corrosion in India

    Energy Technology Data Exchange (ETDEWEB)

    Rajagopalan, K S; Rangaswamy, N S

    1979-03-01

    A survey covers the cost of corrosion in India; methods of preventing corrosion in industrial plants; some case histories, including the prevention of corrosion in pipes through which fuels are pumped to storage and the stress-corrosion cracking of evaporators in fertilizer plants; estimates of the increase in demand in 1979-89 for anticorrosion products and processes developed by the Central Electrochemical Research Institute (CECRI) at Karaikudi, India; industries that may face corrosion problems requiring assistance from CECRI, including the light and heavy engineering structural, and transport industries and the chemical industry; and some areas identified for major efforts, including the establishment of a Corrosion Advisory Board with regional centers and the expansion of the Tropical Corrosion Testing Station at Mandapam Camp, Tamil Nadu.

  4. La formación de la imagen turística inducida: un modelo conceptual

    Directory of Open Access Journals (Sweden)

    Raquel Camprubí

    2009-01-01

    más influyentes para la competitividad de los destinos turísticos, el principal objetivo de este artículo es construir un marco conceptual que muestre la influencia de la red relacional del destino en su imagen emitida. En este contexto, se asume que la imagen turística es una construcción social resultante de la interacción de los distintos agentes que intervienen en el destino turístico (administraciones públicas, instituciones locales, empresas turísticas, etc.; y se propone un modelo teórico para mostrar los efectos de la red relacional del destino turístico en la calidad de la imagen turística creada en términos de conocimiento generado y, por tanto, en su competitividad.

  5. Mutagénesis inducida en microbulbos de Allium sativum L.

    Directory of Open Access Journals (Sweden)

    Adriana Pardo Roldán

    2015-07-01

    Full Text Available Se estableció un protocolo de mutagénesis en microbulbos de ajo (Allium sativum L. clon Boconó cultivado in vitro. Para el efecto se realizaron dos ensayos, uno de radiosensibilidad para establecer la dosimetría apropiada de radiación gamma y otro de mutagénesis para determinar el comportamiento de los materiales hasta la etapa de almacenamiento. En el primero los microbulbos fueron tratados con cuatros dosis de radiación gamma (6, 8, 10 y 12 Krad, más un control. Para establecer la dosis óptima se consideró la sobrevivencia del 50% de los microbulbos (DL50. Se empleó un diseño de bloques al azar con cinco tratamientos y 20 repeticiones por tratamiento. En el ensayo mutagénico los microbulbos fueron irradiados con 8 y 10 Krad y almacenados durante 45 días a 10 °C en condiciones de oscuridad En este caso se utilizó un diseño de bloques al azar con tres tratamientos (0, 8 y 10 Krad y 20 repeticiones por tratamiento. En ambos ensayos, los microbulbos irradiados con 8 y 10 Krad registraron los mayores promedios para peso y diámetro, lo cual permite concluir que estas dosis son adecuadas para favorecer la producción de mutantes con características agronómicas deseables en el clon Boconó

  6. Evaluación de la reproducción inducida del blanquillo ( Sorubim cuspicaudus Littmann, Burr Nass, 2000 con ovaprim®.

    Directory of Open Access Journals (Sweden)

    Víctor Atencio G

    2003-01-01

    Full Text Available El blanquillo ( Sorubim suspicaudus Littmann, Burr &Nass, 2000 presenta características de importanciapara la acuicultura, destacándose la calidad de sucarne y el alto valor comercial. No se reproduce enconfinamiento, por lo que es necesario sureproducción inducida con sustancias hormonales.Responde bien a la inducción con extracto de pituitariade capa (EPC; sin embargo, no se ha evaluado suinducción con extracto de análogos deGonodotropine Releasing Hormone de salmón(sGnRH-a y domperidone en un vehículo inerte. Porlo tanto, entre mayo y noviembre/02, se evaluó eldesempeño reproductivo del blanquillo inducido condiferentes dosificaciones de Ovaprim®: 0.25 (T2,0.050 (T3 y 0.75 ml/kg de peso vivo (T4, aplicadoen una sola dosificación, por inyección en la basede la aleta pectoral. Además, un grupo fue inducidocon 8 mg EPC/kg de peso vivo (TI, en dos inyeccionesde 10 y7 90% de la dosis total, con intervalo de 6horas, por vía intramuscular. Se indujeron entre seisy nueve hembras por tratamiento con igual númerode machos. El desempeño reproductivo fue evaluadomediante el índice de ovulación (hembras ovuladas/hembras tratadas, tasa de fertilización medida a las4 horas pos-eclosión (HPF, tasa de eclosión medidaa las 10 HPF y la fecundidad tanto absoluta comorelativa. El Ovaprim® mostró ser efectivo para inducirla ovulación del blanquillo en las dosificacionesevaluadas (0.25 a 0.75 mL/kg, con respuestassimilares en el desempeño reproductivo a lasobtenidas en EPC. La ovulación con Ovaprim® seobtuvo entre las 12.8 y 14.0 horas con temperaturapromedio del agua de 27.3ºC. El índice de ovulaciónosciló entre 66.7% (T2 y 83.3% (T3; la tasa defertilización osciló entre 88.0% (T3 y 42.0% (T1; latasa de eclosión osciló entre 83.7% (T3 y 40.3%(T1;la fecundidad absoluta osciló entre 40370.6 (T1 y82992.5 ovocitos/hembra (T2; la fecundad relativa,expresada en gramos de ovocitos/kg de hembra,osciló entre 32.1 (T3 y 63.1(T2; el di

  7. Respuesta productiva de gallinas semipesadas inducidas al descanso ovárico en diferentes edades

    Directory of Open Access Journals (Sweden)

    Luis Galeano V.

    2012-12-01

    Full Text Available Objetivo. Evaluar el efecto de la inducción al descanso ovárico (DO a diferentes edades sobre la respuesta productiva en aves semipesadas productoras de huevo comercial. Materiales y método. Se usaron 840 aves de la línea Hy Line Brown con 64 semanas de edad, distribuidas en 10 tratamientos, consistentes en tres edades (65, 70 y 75 semanas con la aplicación de tres períodos de ayuno (5, 10 y 15 días y un control (sin DO. El análisis estadístico utilizó un modelo completamente aleatorizado, anidado, efecto fijo y balanceado. Se evaluó consumo de calcio durante el ayuno (g/ave/día, consumo de alimento (g/ave/día, porcentaje de producción, peso del huevo (g, conversión por masa de huevo y huevos por ave alojada (HAA. Resultados. La edad presentó efecto significativo (p<0.05 sobre las variables consumo de alimento, día del primer huevo postmuda, días sin producción, día postmuda de retorno al 50% de producción, peso del huevo, número de huevos, masa huevos, conversión y porcentaje de producción (p<0.01. Al comparar con el control, el tratamiento 75-5 presentó efecto significativo (p<0.05 para las variables: consumo de alimento, número de huevos promedio, masa huevos y conversión. Conclusiones. Las aves con mayor período de ayuno presentaron mayor período improductivo postmuda, grandes pérdidas de peso y alto consumo de alimento, lo que genera alta conversión e ineficiencia productiva. En comparación con reportes de literatura sobre DO en aves livianas, las aves semipesadas llegan al cese de producción en menos días y su período improductivo es menor.

  8. Corrosion principles and surface modification

    International Nuclear Information System (INIS)

    Kruger, J.

    1982-01-01

    This chapter examines the important strategies provided by the newer ideas of corrosion science and engineering that surface modification techniques must utilize to help prevent corrosion, especially the most damaging kind of aqueous corrosion, localized corrosion. Provides a brief introduction to the principles underlying the phenomenon of corrosion in order to use them to discuss surface modification strategies to combat corrosion. Discusses the electrochemistry of corrosion; the thermodynamics of corrosion; the kinetics of corrosion; thermodynamic strategies; and kinetic strategies (formation of more protective passive films; resistance to breakdown; ductility; repassivation)

  9. Hot corrosion of the steel SA213-T22 and SA213-TP347H in 80% V{sub 2}O{sub 5}-20%Na{sub 2}SO{sub 4} mixture; Corrosion por depositos salinos de los aceros SA213-T22 y SA213-TP347H en presencia de una mezcal 80%V{sub 2} O{sub 5}-20%Na{sub 2}SO{sub 4}

    Energy Technology Data Exchange (ETDEWEB)

    Almeraya, F; Martinez-Villafane, A; Gaona, C; Romero, M A; Malo, J M

    1998-06-01

    Many hot corrosion problems in industrial and utility boilers are caused by molten salts. The corrosion processes which occur in salts are of an electrochemical nature, and so they can be studied using electrochemical test methods. In this research, electrochemical techniques in molten salt systems have been used for the measurements of molten corrosion processes. Electrochemical test methods are described here for a salt mixture of 80%V{sub 2}O{sub 5}-20%NaSO{sub 4} at 540-680 degree centigree. To establish better the electrochemical corrosion rate measurements for molten salt systems, information from electrochemical potentiodynamic polarization curves, such as polarization resistance and Tafeol slopes were used in this study to generate corrosion rate data. The salt was contained in a quartz crucible inside a stainless retort. The atmosphere used was air. A thermocouple sheathed with quartz glass was introduced into the molten salt for temperature monitoring and control. Two materials were tested in the molten mixture: SA213-T22 and SA213-TP347H steels. The corrosion rates values obtained using electrochemical methods were around 0.58-7.14 mm/yr (22.9-281 mpy). The corrosion rate increase with time. (Author) 7 refs.

  10. Dominância coronariana em corações humanos em moldes por corrosão Coronary dominance patterns in the human heart investigated by corrosion casting

    Directory of Open Access Journals (Sweden)

    Décio Cavalet Soares Abuchaim

    2009-12-01

    Full Text Available OBJETIVO: Esse trabalho tem como objetivo analisar os padrões de dominância circulatória de corações humanos, o número de ramos que a artéria coronária direita fornece ao ventrículo esquerdo, o número de ramos que a artéria coronária esquerda fornece ao direito e a presença de anastomoses intercoronarianas, com sua localização e frequência. MÉTODOS: Foram produzidos 25 moldes de corações submetidos à instilação de acrílico colorido e posterior corrosão com ácido clorídrico, no Laboratório de Cirurgia Experimental da FURB. Peças com lesões e cicatrizes não foram usadas. RESULTADOS: Os corações pertenciam a indivíduos de ambos os sexos, sendo 17 (68% de indivíduos do sexo masculino, com idade média de 40,2 anos (15 a 70 anos. A dominância direita ocorreu em 18 (72% peças, com 1, 2, 3 e 4 ramos em 2, 14, 2 e 1 moldes, respectivamente; a dominância esquerda foi observada em 5 (20% casos, com 1 ramo em 4 moldes e 2 em 1 molde; e a dominância balanceada foi verificada em 2 (8% moldes. Houve diferença significativa entre a dominância direita e esquerda (α > 5%, direita e balanceada (α > 5% e sem significância entre esquerda e balanceada (α OBJECTIVES: The aim of this work was to analyze the dominance patterns of the circulation of the human heart, the number of branches from the right coronary artery to the left ventricle, the number of branches from the left coronary artery to the right ventricle and the frequency and location of intercoronary anastomoses. METHODS: Casts were made of 25 hearts by the injection of colored acrylic resin and subsequent corrosion using hydrochloric acid at the experimental surgery laboratory of Furb. Specimens with lesions or scars were discarded. RESULTS: The hearts, from both men (17 - 68% and women (8 - 32%, had a mean age of 40.2 (15 to 70 years-old. Right dominance occurred in 18 (72% subjects, with 1, 2, 3 and 4 branches leading to the left ventricle in 2, 14, 2 and 2

  11. CARACTERIZACIÓN EXPERIMENTAL DE LA CONCENTRACIÓN DE HOLLÍN EN LLAMAS DIESEL MEDIANTE INCANDESCENCIA INDUCIDA POR LÁSER

    OpenAIRE

    BUITRAGO GARCÍA, JORGE ENRIQUE

    2016-01-01

    [EN] Laser-induced incandescence (LII) is an optical diagnostic technique that can be used to measure the concentration and primary-particle size distributions of soot with high selectivity. This technique consists of rapid particle heating from the local ambient temperature to close to the soot sublimation temperature (~4000 K) by means of a highly energetic laser source, and the immediate recording of the strong thermal radiation as a result of a complex heat and mass transfer balance. The ...

  12. Disminución del daño oxidativo y efecto hipoglicemiante de la maca (Lepidium meyenii Walp) en ratas con diabetes inducida por streptozotocina

    OpenAIRE

    María Elena Rodrigo; Rubén Valdivieso; Silvia Suárez; Rosa Oriondo; Raquel Oré

    2011-01-01

    Introducción: La maca es consumida desde tiempos ancestrales como parte de la dieta. Se le ha atribuido propiedades medicinales y se encuentra incluida en la medicina tradicional peruana. Estudios recientes describen que la admistración de maca reduce la glicemia en animales normoglicémicos, pero los mecanismos involucrados no están muy claros. Objetivos: Determinar el efecto hipoglicemiante y antioxidante de la harina de maca (Lepidium meyenii Walp) del ecotipo amarillo, en ratas con diabete...

  13. Participación del óxido nítrico en las alteraciones comportamentales y neuroendócrinas inducidas por estrés prenatal

    OpenAIRE

    Maur, Damián Gustavo

    2015-01-01

    Durante el desarrollo prenatal los organismos son vulnerables a factores que pueden afectar su homeostasis. Ha sido demostrado que el estrés durante la preñez tiene efectos en la descendencia que pueden perdurar hasta la adultez, afectando numerosos procesos fisiológicos. Sin embargo, los mecanismos subyacentes aún no han sido completamente dilucidados. El objetivo de esta tesis fue estudiar la participación del óxido nítrico (NO) en las alteraciones comportamentales y neuroendócrinas inducid...

  14. Efecto preventivo de un extracto de cacao enriquecido en polifenoles sobre ratas con alteraciones endocrino metabólicas inducidas por sacarosa

    OpenAIRE

    Villagarcía, Hernán Gonzalo; González Arbeláez, Luisa Fernanda; Castro, María Cecilia; Ríos, José Luis; Massa, María Laura; Schinella, Guillermo Raúl; Francini, Flavio

    2016-01-01

    Existe una creciente evidencia de que el consumo de ciertos alimentos, suplementos alimenticios o bebidas tradicionales puede reducir el daño oxidativo en diferentes sistemas biológicos. Alimentos derivados del cacao, tales como polvos de cacao, chocolate y otros productos relacionado con el cacao son alimentos ricos en polifenoles derivados de las semillas fermentadas, tostados y procesados industrialmente de Theobroma cacao L. (Sterculiaceae). Estos productos, consumidos en todo el mundo...

  15. First Patagonian Course on 'Diagnosis and Therapy of Injuries Induced by Ionizing Radiation'; Primer curso patagonico 'Diagnostico y Tratamiento de Lesiones Inducidas por Radiaciones Ionizantes'

    Energy Technology Data Exchange (ETDEWEB)

    Bellotti, Mariela I., E-mail: bellotti@cab.cnea.gov.ar [Comision Nacional de Energia Atomica (CAB/CNEA), San Carlos de Bariloche (Argentina). Centro Atomico Bariloche. Lab. de Cavitacion y Biotecnologia; Andres, Pablo A., E-mail: andresp@cab.cnea.gov.ar [Comision Nacional de Energia Atomica (CAB/CNEA), San Carlos de Bariloche (Argentina). Centro Atomico Bariloche. Division Proteccion Radiologica; Cascón, Adriana S., E-mail: adrianacascon@yahoo.com [Instituto de Medicina, Radiomedicina y Seguridad (IMERASE SA), Buenos Aires, (Argentina)

    2013-07-01

    In Patagonia there are academic centers, health and industrial facilities that use ionizing radiations in its usual practices. However, they do not have protocols that respond to local needs. For this reason was held from October 5 to November 10, 2012 in Bariloche Atomic Center, a training course for health personnel. The range of topics covered ranged from the definition of dosimetry quantities, types of radiation and biological dosimetry, biological effects, radiation acute syndrome, radiation-induced cutaneous syndrome, internal contamination, screening in radiological emergencies, etc.The course provided a theoretical and practical guide about how to recognize and treat people exposed to radiations, guidelines for acting in radiological emergencies and a perception of the psychosocial impact of the radiation accidents.The result was a pocket book for health personnel that will be used in case of having a patient with radiation induced injury.

  16. Psicosis inducida ("foliex a deux" e intoxicación crónica por plomo.: Reporte de un caso y discusión.

    Directory of Open Access Journals (Sweden)

    Jaime Arias

    1996-04-01

    Full Text Available We report a case of two brothers suffering the same paranoia psychosis. The older one presented an altered consciousness and needed hospitalization. During hospitalization, he was considered as having lead chronic intoxication. The lead serum level was 65 ug/dl (N:<30 ug/dl and the lead hair was 25 pg/gr-tiss (N:<10 pg/gr-tiss. He also presented clinically with encephalopathy, disorder of the autonomic dysfunction. He leaded his body for eleven years because of delutional ideas, and induced these ideas and behavior to his brother (folie a deux. The coincidence between these disorders in extremely rare so we believe this case report is of clinical interesting. (Rev Med Hered 1996; 7: 101-104.

  17. Papel de hemo oxigensa-1 en la artritis inducida por transferencia de suero K/BxN. Caracterización del modelo experimental

    OpenAIRE

    Brines Juan, Rita

    2017-01-01

    La Artritis Reumatoide (AR) es una enfermedad sistémica, crónica y de carácter autoinmune que produce daño articular en los pacientes. Cursa con la degradación del hueso subcondral y del cartílago articular causando un gran dolor; además de ser una enfermedad incapacitante, puede provocar síntomas extraarticulares que afecten a otros órganos. El estudio de la patogenia y del tratamiento de la AR se desarrolla en gran medida sobre modelos animales de artritis experimental. En la actualidad...

  18. Hipoglucemia facticia inducida por insulina en un paciente diabético tipo 1 Facticious hypoglycaemia induced by insulin in a type 1 diabetic patient

    Directory of Open Access Journals (Sweden)

    Tania Espinosa Reyes

    2004-12-01

    Full Text Available La hipoglucemia facticia es un atentado deliberado para provocar niveles séricos bajos de glucosa con el uso de insulina o de agentes hipoglucemiantes orales. Paciente JCB, masculino, 12 años, blanco, diabético tipo 1 de 2 años de evolución. Motivo de consulta: episodios de hipoglucemia severa con convulsiones y coma. Se tomaron muestras para anticuerpos antiislotes pancreáticos (ICA y péptido C en condiciones basales y durante la hipoglucemia, así como determinaciones de hemoglobina glucosilada (HBA1 durante la evolución de la enfermedad, ultrasonografía, tomografía axial computadorizada (TAC y resonancia magnética nuclear (RMN de páncreas. Se obtuvieron insulinemias elevadas, valores extremadamente disminuidos de peptinemia C, incremento del índice de masa corporal y función renal y hepática dentro de parámetros normales. Los estudios imagenológicos fueron normales. Se concluye que a pesar de la relativa baja frecuencia de la hipoglucemia facticia en el diabético, es imprescindible tenerla en cuenta. La detección precoz facilita la atención psicológica temprana del paciente y previene la exposición a acciones que impliquen riesgo para la vida o daño permanente.Factitious hypoglycaemia is a deliberate attempt to provoke low serum levels of glucose by using insulin or lowering-glycaemia agents. A case is reported of a white, male, 12-year-old type 1 diabetic patient of 2 years of evolution. Chief complaint: episodes of severe hypoglycaemia with convulsions and coma. Samples for pancreatic anti-islet cell antibodies and peptide C were taken under basal conditions and during hypoglycaemia. Determinations of glucosylated haemoglobin (HBA1 during the evolution of the disease, ultrasonography, CAT and nuclear magnetic imaging of pancreas were performed. Elevated insulinemias, extremely reduced values of peptinemia C, increase of the body mass index, and renal and hepatic function within the normal parameters were obtained. The imaging studies were normal. It was concluded that in spite of the relative low frequency of factitious hypoglycemia in the diabetic, it is indispensable to take it into account. The premature detection makes easy the early psychological attention of the patient and prevents the exposure to actions implying risk for life or permanent damage.

  19. Thermoluminescence induced by X-rays in silica materials with metallic impurities; Termoluminiscencia inducida por los rayos X en materiales de silice con impurezas metalicas

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza A, D.; Gonzalez M, P.; Espinosa P, M. [Instituto nacional de Investigaciones Nucleares, A.P. 18-1027, Mexico D.F. (Mexico); Salas, P.; Castano, V.M. [Instituto de Fisica, UNAM, Laboratorio Juriquilla, A.P. 1-1010, C.P. 76001, Queretaro (Mexico)

    1999-07-01

    Diverse materials of silica with Fe, Cu, Mg, and Mn impurities were synthesized by the sol-gel method, using tetraethyl orthosilicate as precursor. The materials obtained were subjected to thermal treatment at 500, 700 and 1000 Centigrade also they were irradiated with X-ray generated by a X-ray diffractometer which is installed in the ININ. The thermoluminescent signal was analysed and correlated with the type of impurities that are present in the material and with the grade of crystallinity produced by the thermal treatment in them. In according to the results obtained these materials show a thermoluminescent signal which is influenced by the crystallinity grade. It was analysed the behavior of the response for different doses, with the purpose of utilizing them to quantify very intense fields of radiation. (Author)

  20. Papel del endotelio en hipertensión inducida por el embarazo: ¿alteraciones comunes a las de la aterosclerosis?

    OpenAIRE

    López-Jaramillo, Patricio; Sotomayor Rubio, Katherine; Sotomayor-Rubio, Arístides; López López, Cristina

    2014-01-01

    Pregnancy induced hypertension, called preeclampsia (PE) when accompanied by proteinuria, is an alteration that occurs in the second trimester of pregnancy and is characterized by presence of hypertension and proteinuria. Adaptative physiologic changes occur during normal pregnancy including insulin-resistance (IR), hyperlipidemia, hypercoagulability, inflammation, and hyperdynamic circulatory status. Expression of these changes is exaggerated in women developing PE. These alterations are als...

  1. RESISTIVIDAD INDUCIDA POR SCATTERING ELECTRON-SUPERFICIE RUGOSA Y SCATTERING ELECTRON BORDE DE GRANO EN PELICULAS DELGADAS DE ORO DEPOSITADAS SOBRE MICA

    OpenAIRE

    HENRIQUEZ CORREA; RICARDO ANDRES; HENRIQUEZ CORREA; RICARDO ANDRES

    2010-01-01

    En este trabajo se presenta un método experimental que permite separar el efecto de las colisiones electrón-borde de grano y electrón-superficie sobre la resistividad eléctrica en películas delgadas de oro evaporadas sobre mica. Cuando el efecto de las colisiones electrón-borde de grano es dominante, la resistividad no depende del espesor de la muestra, el camino libre medio a 4 K es el diámetro medio de grano, la dependencia de la resistividad con temperatura puede ser descrit...

  2. Monitoring Microbially Influenced Corrosion

    DEFF Research Database (Denmark)

    Hilbert, Lisbeth Rischel

    and diffusional effects and unreliable corrosion rates, when biofilm and ferrous sulphide corrosion products cover the steel surface. Corrosion rates can be overestimated by a factor of 10 to 100 by electrochemical techniques. Weight loss coupons and ER are recommended as necessary basic monitoring techniques......Abstract Microbially influenced corrosion (MIC) of carbon steel may occur in media with microbiological activity of especially sulphate-reducing bacteria (SRB). The applicability and reliability of a number of corrosion monitoring techniques for monitoring MIC has been evaluated in experiments....... EIS might be used for detection of MIC as the appearance of very large capacitances can be attributed to the combined ferrous sulphide and biofilm formation. Capacitance correlates directly with sulphide concentration in sterile sulphide media. Keywords: Corrosion monitoring, carbon steel, MIC, SRB...

  3. SRB seawater corrosion project

    Science.gov (United States)

    Bozack, M. J.

    1991-01-01

    The corrosion behavior of 2219 aluminum when exposed to seawater was characterized. Controlled corrosion experiments at three different temperatures (30, 60 and 100 C) and two different environments (seawater and 3.5 percent salt solution) were designed to elucidate the initial stages in the corrosion process. It was found that 2219 aluminum is an active catalytic surface for growth of Al2O3, NaCl, and MgO. Formation of Al2O3 is favored at lower temperatures, while MgO is favored at higher temperatures. Visible corrosion products are formed within 30 minutes after seawater exposure. Corrosion characteristics in 3.5 percent salt solution are different than corrosion in seawater. Techniques utilized were: (1) scanning electron microscopy, (2) energy dispersive x-ray spectroscopy, and (3) Auger electron spectroscopy.

  4. Corrosion control. 2. ed.

    International Nuclear Information System (INIS)

    Bradford, S.A.

    2001-01-01

    The purpose of this text is to train engineers and technologists not just to understand corrosion but to control it. Materials selection, coatings, chemical inhibitors, cathodic and anodic protection, and equipment design are covered in separate chapters. High-temperature oxidation is discussed in the final two chapters ne on oxidation theory and one on controlling oxidation by alloying and with coatings. This book treats corrosion and high-temperature oxidation separately. Corrosion is divided into three groups: (1) chemical dissolution including uniform attack, (2) electrochemical corrosion from either metallurgical or environmental cells, and (3) stress-assisted corrosion. Corrosion is logically grouped according to mechanisms rather than arbitrarily separated into different types of corrosion as if they were unrelated. For those university students and industry personnel who approach corrosion theory very hesitantly, this text will present the electrochemical reactions responsible for corrosion summed up in only five simple half-cell reactions. When these are combined on a polarization diagram, which is also explained in detail, the electrochemical processes become obvious. For those who want a text stripped bare of electrochemical theory, several noted sections can be omitted without loss of continuity. However, the author has presented the material in such a manner that these sections are not beyond the abilities of any high school graduate who is interested in technology

  5. Coatings and Corrosion Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — Purpose: The mission of the Coatings and Corrosion Laboratory is to develop and analyze the effectiveness of innovative coatings test procedures while evaluating the...

  6. Pérdida auditiva por contaminación acústica laboral en Santiago de Chile

    OpenAIRE

    Salazar Bugueño, Ana María

    2013-01-01

    [spa] La Organización Mundial de la Salud (OMS) ha estimado que, aproximadamente, 278 millones de personas presentan déficit auditivo en el mundo; que el 50% de las pérdidas auditivas podrían evitarse mediante prevención, un diagnóstico precoz y una gestión eficaz y que, más de 4.000.000 de años de vida saludable se perdieron debido a las pérdidas auditivas inducidas por ruido. Lo anterior hace necesario establecer un modelo para predecir la pérdida auditiva por contaminación acústica laboral...

  7. Corrosion in the oil industry

    Energy Technology Data Exchange (ETDEWEB)

    Brondel, D [Sedco Forex, Montrouge (France); Edwards, R [Schlumberger Well Services, Columbus, OH (United States); Hayman, A [Etudes et Productions Schlumberger, Clamart (France); Hill, D [Schlumberger Dowell, Tulsa, OK (United States); Mehta, S [Schlumberger Dowell, St. Austell (United Kingdom); Semerad, T [Mobil Oil Indonesia, Inc., Sumatra (Indonesia)

    1994-04-01

    Corrosion costs the oil industry billions of dollars a year, a fact that makes the role of the corrosion engineer an increasingly important one. Attention is paid to how corrosion affects every aspect of exploration and production, from offshore rigs to casing. Also the role of corrosion agents such as drilling and production fluids is reviewed. Methods of control and techniques to monitor corrosion are discussed, along with an explanation of the chemical causes of corrosion. 21 figs., 32 refs.

  8. Corrosion evaluation technology

    International Nuclear Information System (INIS)

    Kim, Uh Chul; Han, Jeong Ho; Nho, Kye Ho; Lee, Eun Hee; Kim, Hong Pyo; Hwang, Seong Sik; Lee, Deok Hyun; Hur, Do Haeng; Kim, Kyung Mo.

    1997-09-01

    A multifrequency ACPD system was assembled which can measure very small crack. Stress corrosion cracking test system with SSRT operating high temperature was installed. Stress corrosion cracking test of newly developed alloy 600 and existing alloy 600 was carried out in steam atmosphere of 400 deg C. No crack was observed in both materials within a test period of 2,000 hrs. Corrosion fatigue test system operating at high temperature was installed in which fatigue crack was measured by CDPD. Lead enhanced the SCC of the Alloy 600 in high temperature water, had a tendency to modify a cracking morphology from intergranular to transgranular. Pit initiation preferentially occurred at Ti-rich carbide. Resistance to pit initiation decreased with increasing temperature up to 300 deg C. Test loop for erosion corrosion was designed and fabricated. Thin layer activation technique was very effective in measuring erosion corrosion. Erosion corrosion of a part of secondary side pipe was evaluated by the Check Family Codes of EPRI. Calculated values of pipe thickness by Check Family Codes coincided with the pipe thickness measured by UT with an error of ± 20%. Literature review on turbine failure showed that failure usually occurred in low pressure turbine rotor disc and causes of failure are stress corrosion cracking and corrosion fatigue. (author). 12 refs., 20 tabs., 77 figs

  9. Aluminum Corrosion and Turbidity

    International Nuclear Information System (INIS)

    Longtin, F.B.

    2003-01-01

    Aluminum corrosion and turbidity formation in reactors correlate with fuel sheath temperature. To further substantiate this correlation, discharged fuel elements from R-3, P-2 and K-2 cycles were examined for extent of corrosion and evidence of breaking off of the oxide film. This report discusses this study

  10. Demystifying Controlling Copper Corrosion

    Science.gov (United States)

    The LCR systematically misses the highest health and corrosion risk sites for copper. Additionally, there are growing concerns for WWTP copper in sludges and discharge levels. There are many corrosion control differences between copper and lead. This talk explains the sometimes c...

  11. Archaeological analogs and corrosion

    International Nuclear Information System (INIS)

    David, D.

    2008-01-01

    In the framework of the high level and long life radioactive wastes disposal deep underground, the ANDRA built a research program on the material corrosion. In particular they aim to design containers for a very long time storage. Laboratory experiments are in progress and can be completed by the analysis of metallic archaeological objects and their corrosion after hundred years. (A.L.B.)

  12. Erosion and erosion-corrosion

    International Nuclear Information System (INIS)

    Isomoto, Yoshinori

    2008-01-01

    It is very difficult to interpret the technical term of erosion-corrosion' which is sometimes encountered in piping systems of power plants, because of complicated mechanisms and several confusing definitions of erosion-corrosion phenomena. 'FAC (flow accelerated corrosion)' is recently introduced as wall thinning of materials in power plant systems, as a representative of 'erosion-corrosion'. FAC is, however, not necessarily well understood and compared with erosion-corrosion. This paper describes firstly the origin, definition and fundamental understandings of erosion and erosion-corrosion, in order to reconsider and reconfirm the phenomena of erosion, erosion-corrosion and FAC. Next, typical mapping of erosion, corrosion, erosion-corrosion and FAC are introduced in flow velocity and environmental corrosiveness axes. The concept of damage rate in erosion-corrosion is finally discussed, connecting dissolution rate, mass transfer of metal ions in a metal oxide film and film growth. (author)

  13. Exploratory shaft liner corrosion estimate

    International Nuclear Information System (INIS)

    Duncan, D.R.

    1985-10-01

    An estimate of expected corrosion degradation during the 100-year design life of the Exploratory Shaft (ES) is presented. The basis for the estimate is a brief literature survey of corrosion data, in addition to data taken by the Basalt Waste Isolation Project. The scope of the study is expected corrosion environment of the ES, the corrosion modes of general corrosion, pitting and crevice corrosion, dissimilar metal corrosion, and environmentally assisted cracking. The expected internal and external environment of the shaft liner is described in detail and estimated effects of each corrosion mode are given. The maximum amount of general corrosion degradation was estimated to be 70 mils at the exterior and 48 mils at the interior, at the shaft bottom. Corrosion at welds or mechanical joints could be significant, dependent on design. After a final determination of corrosion allowance has been established by the project it will be added to the design criteria. 10 refs., 6 figs., 5 tabs

  14. Corrosion fatigue of steels

    International Nuclear Information System (INIS)

    Spaehn, H.; Wagner, G.H.

    1976-01-01

    Corrosion fatigue phenomena can be classified into two main groups according to the electrochemical state of the metal surface in the presence of electrolytes: the active and the passive state with an important sub-group of corrosion fatigue in the unstable passive state. The allowable stress for structures exposed to the conjoint action of corrosion and fatigue is influenced by many factors: kind of media, number of cycles, frequency, mean stress, size, notches, loading mode, alloy composition and mechanical strength. A critical literature review shows contradictory results if a classification by the electrochemical surface state is not applied. Case histories and counter measures illustrate the practical importance of corrosion fatigue in many branches of industry as well as the urgent need for a better knowledge about the mutual influence of the phenomena to get rules by which the engineer can appraise the risk of corrosion fatigue. (orig.) [de

  15. Estatus de parámetros oxidativos y del gen p53 en sangre de niños en edad escolar de zonas afectadas por el accidente nuclear de Chernobyl.

    OpenAIRE

    García Mora, Mª Carmen

    2004-01-01

    RESUMEN Tras el accidente nuclear de Chernobyl producido el 26 de abril de 1986 se liberaron muchos radioisótopos, produciendo la contaminación del medio ambiente, con la consiguiente implicación sobre la salud de las personas afectadas. La irradiación produce su efecto sobre el material biológico de manera directa, como consecuencia inmediata de la ionización inducida por la irradiación y de manera indirecta, que al interaccionar sobre cualquier estructura celular, esencialmente el agua t...

  16. Automated Methods Of Corrosion Measurements

    DEFF Research Database (Denmark)

    Bech-Nielsen, Gregers; Andersen, Jens Enevold Thaulov; Reeve, John Ch

    1997-01-01

    The chapter describes the following automated measurements: Corrosion Measurements by Titration, Imaging Corrosion by Scanning Probe Microscopy, Critical Pitting Temperature and Application of the Electrochemical Hydrogen Permeation Cell.......The chapter describes the following automated measurements: Corrosion Measurements by Titration, Imaging Corrosion by Scanning Probe Microscopy, Critical Pitting Temperature and Application of the Electrochemical Hydrogen Permeation Cell....

  17. Neumonitis por hipersensibilidad en la ciudad de México

    Directory of Open Access Journals (Sweden)

    Carrillo-Rodríguez José G.

    2000-01-01

    Full Text Available OBJETIVO: Determinar la asociación entre la zona urbana de origen del paciente en la ciudad de México y la prevalencia de neumonitis por hipersensibilidad inducida por antígeno aviario. MATERIAL Y MÉTODOS: Se trata de un estudio de casos y controles realizado en el Instituto Nacional de Enfermedades Respiratorias, en la ciudad de México, en el año de 1999. Se estudiaron 109 casos con neumonitis por hipersensibilidad y 184 controles: de éstos, 39, con fibrosis pulmonar idiopática; 63, con tuberculosis pulmonar, y 82, con asma. La ciudad de México y las zonas conurbadas se dividieron en cinco zonas geográficas: centro, noreste, sureste, noroeste y el suroeste. Se calcularon las prevalencias de las diferentes enfermedades por zona urbana de los pacientes que participaron en el estudio; como medida de asociación, se estimó la razón de momios, con un intervalo de confianza al 95%. Asimismo, se realizó regresión logística múltiple ajustando por edad, sexo y estrato socioeconómico. RESULTADOS: Ochenta casos de neumonitis por hipersensibilidad se concentraron en el sur del noreste de las zonas conurbadas y la parte norte del sureste de la ciudad de México, 48 y 32, respectivamente (RM= 3.86, IC 95% 2.17-6.96. Treinta y seis controles de asma se localizaron en el suroeste de la ciudad de México, zona donde se ubica el Intituto Nacional de Enfermedades Respiratorias (p<0.05 y cuatro en la zona conurbada. Los controles de tuberculosis pulmonar y fibrosis pulmonar idiopática estuvieron dispersos en la ciudad de México y en las zonas conurbadas. CONCLUSIONES: La zona sur del noreste y el norte de la sureste están asociadas a la neumonitis por hipersensibilidad. Las causas de esta asociación no parece ser geográfica, pero existe el antecedente de que esa zona fue basurero de la ciudad, por lo que partículas orgánicas en el ambiente pudieran coadyuvar a la aparición de esta enfermedad.

  18. Corrosion in power industry

    International Nuclear Information System (INIS)

    Ventakeshwarlu, K.S.

    1979-01-01

    A brief account of the problem areas encountered as a result of corrosion in the electrical power industry including nuclear power industry is given and some of the measures contemplated and/or implemented to control corrosion are outlined. The corrosion problems in the steam generators and cladding tubes of the nuclear power plant have an added dimension of radioactivation which leads to contamination and radiation field. Importance of monitoring water quality and controlling water chemistry by addition of chemicals is emphasised. (M.G.B.)

  19. Corrosion of reactor materials

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1963-01-15

    Much operational experience and many experimental results have accumulated in recent years regarding corrosion of reactor materials, particularly since the 1958 Geneva Conference on the Peaceful Uses of Atomic Energy, where these problems were also discussed. It was, felt that a survey and critical appraisal of the results obtained during this period had become necessary and, in response to this need, IAEA organized a Conference on the Corrosion of Reactor Materials at Salzburg, Austria (4-9 June 1962). It covered many of the theoretical, experimental and engineering problems relating to the corrosion phenomena which occur in nuclear reactors as well as in the adjacent circuits

  20. Modelling reinforcement corrosion in concrete

    DEFF Research Database (Denmark)

    Michel, Alexander; Geiker, Mette Rica; Stang, Henrik

    2012-01-01

    A physio-chemical model for the simulation of reinforcement corrosion in concrete struc-tures was developed. The model allows for simulation of initiation and subsequent propaga-tion of reinforcement corrosion. Corrosion is assumed to be initiated once a defined critical chloride threshold......, a numerical example is pre-sented, that illustrates the formation of corrosion cells as well as propagation of corrosion in a reinforced concrete structure....

  1. Corrosion of PWR steam generators

    International Nuclear Information System (INIS)

    Garnsey, R.

    1979-01-01

    Some designs of pressurized water reactor (PWR) steam generators have experienced a variety of corrosion problems which include stress corrosion cracking, tube thinning, pitting, fatigue, erosion-corrosion and support plate corrosion resulting in 'denting'. Large international research programmes have been mounted to investigate the phenomena. The operational experience is reviewed and mechanisms which have been proposed to explain the corrosion damage are presented. The implications for design development and for boiler and feedwater control are discussed. (author)

  2. Corrosion of valve metals

    International Nuclear Information System (INIS)

    Draley, J.E.

    1976-01-01

    A general survey related to the corrosion of valve metals or film-forming metals. The way these metals corrode with some general examples is described. Valve metals form relatively perfect oxide films with little breakdown or leakage when anodized

  3. Corrosion in Electronics

    DEFF Research Database (Denmark)

    Ambat, Rajan; Gudla, Helene Virginie Conseil; Verdingovas, Vadimas

    2017-01-01

    Electronic control units, power modules, and consumer electronics are used today in a wide variety of varying climatic conditions. Varying external climatic conditions of temperature and humidity can cause an uncontrolled local climate inside the device enclosure. Uncontrolled humidity together...... and high density packing combined with the use of several materials, which can undergo electrochemical corrosion in the presence of water film formed due to humidity exposure and bias conditions on the PCBA surface. This article provides a short review of the corrosion reliability issues of electronics due...... to the use of electronics under varying humidity conditions. Important PCBA aspects, which are fundamental to the corrosion cell formation under humid conditions, are discussed. Effect of hygroscopic residues from the process and service and their role in assisting water film build up and corrosion...

  4. Microbiologically Influenced Corrosion

    Science.gov (United States)

    2009-01-01

    species grow as multicel- lular filaments called hyphae forming a mycelium, some fungal species also grow as single cells. Sexual and asexual...reinforced fluorinated 18 MICROBIOLOGICALLY INFLUENCED CORROSION polyimide composites due to hyphae penetration into resin interiors. The

  5. Carbon Dioxide Corrosion:

    DEFF Research Database (Denmark)

    Fosbøl, Philip Loldrup

    2008-01-01

    CO2 corrosion is a general problem in the industry and it is expensive. The focus of this study is an oil gas production related problem. CO2 corrosion is observed in offshore natural gas transportation pipelines. A general overview of the problem is presented in chapter 1. The chemical system...... with the basic thermodynamics of electrolytes in chapter 2, the extension and general description of electrolyte mass transport in chapter 3, and the electrochemical kinetics of corrosion in chapter 4. A literature overview of CO2 corrosion is shown in chapter 5 and possible extensions of the models...... and validated against heat capacity data. The model is also fitted to experimental data produced and shown in chapter 8 for SLE in the Na2CO3-NaHCO3-MEG-H2O system. The application of the above model is shown in chapter 9. Here the thermodynamic correction factors are calculated. These show how the diffusion...

  6. BWR steel containment corrosion

    Energy Technology Data Exchange (ETDEWEB)

    Tan, C.P.; Bagchi, G.

    1996-04-01

    The report describes regulatory actions taken after corrosion was discovered in the drywell at the Oyster Creek Plant and in the torus at the Nine Mile Point 1 Plant. The report describes the causes of corrosion, requirements for monitoring corrosion, and measures to mitigate the corrosive environment for the two plants. The report describes the issuances of generic letters and information notices either to collect information to determine whether the problem is generic or to alert the licensees of similar plants about the existence of such a problem. Implementation of measures to enhance the containment performance under severe accident conditions is discussed. A study by Brookhaven National Laboratory (BNL) of the performance of a degraded containment under severe accident conditions is summarized. The details of the BNL study are in the appendix to the report.

  7. Corrosion Inhibitors for Aluminum.

    Science.gov (United States)

    Muller, Bodo

    1995-01-01

    Describes a simple and reliable test method used to investigate the corrosion-inhibiting effects of various chelating agents on aluminum pigments in aqueous alkaline media. The experiments that are presented require no complicated or expensive electronic equipment. (DDR)

  8. Corrosion of beryllium

    International Nuclear Information System (INIS)

    Mueller, J.J.; Adolphson, D.R.

    1987-01-01

    The corrosion behavior of beryllium in aqueous and elevated-temperature oxidizing environments has been extensively studied for early-intended use of beryllium in nuclear reactors and in jet and rocket propulsion systems. Since that time, beryllium has been used as a structural material in les corrosive environments. Its primary applications include gyro systems, mirror and reentry vehicle structures, and aircraft brakes. Only a small amount of information has been published that is directly related to the evaluation of beryllium for service in the less severe or normal atmospheric environments associated with these applications. Despite the lack of published data on the corrosion of beryllium in atmospheric environments, much can be deduced about its corrosion behavior from studies of aqueous corrosion and the experiences of fabricators and users in applying, handling, processing, storing, and shipping beryllium components. The methods of corrosion protection implemented to resist water and high-temperature gaseous environments provide useful information on methods that can be applied to protect beryllium for service in future long-term structural applications

  9. Monitoring corrosion rates and localised corrosion in low conductivity water

    DEFF Research Database (Denmark)

    Hilbert, Lisbeth Rischel

    2006-01-01

    Monitoring of low corrosion rates and localised corrosion in a media with low conductivity is a challenge. In municipal district heating, quality control may be improved by implementing on-line corrosion monitoring if a suitable technique can be identified to measure both uniform and localised...... corrosion. Electrochemical techniques (LPR, EIS, crevice corrosion current) as well as direct measurement techniques (high-sensitive electrical resistance, weight loss) have been applied in operating plants. Changes in the corrosion processes are best monitored in non-aggressive, low conductivity media...

  10. Corrosion and anticorrosion. Industrial practice

    International Nuclear Information System (INIS)

    Beranger, G.; Mazille, H.

    2002-01-01

    This book comprises 14 chapters written with the collaboration of about 50 French experts of corrosion. It is complementary to another volume entitled 'corrosion of metals and alloys' and published by the same editor. This volume comprises two parts: part 1 presents the basic notions of corrosion phenomena, the properties of surfaces, the electrochemical properties of corrosion etc.. Part 2 describes the most frequent forms of corrosion encountered in industrial environments and corresponding to specific problems of protection: marine environment, atmospheric corrosion, galvanic corrosion, tribo-corrosion, stress corrosion etc.. The first 8 chapters (part 1) treat of the corrosion problems encountered in different industries and processes: oil and gas production, chemical industry, phosphoric acid industry, PWR-type power plants, corrosion of automobile vehicles, civil engineering and buildings, corrosion of biomaterials, non-destructive testing for the monitoring of corrosion. The other chapters (part 2) deal with anticorrosion and protective coatings and means: choice of materials, coatings and surface treatments, thick organic coatings and enamels, paints, corrosion inhibitors and cathodic protection. (J.S.)

  11. Hydrogen peroxide using in control of H{sub 2} S and C N{sup -} corrosion in aqueous medium; Emprego de peroxido de hidrogenio no controle da corrosao por H{sub 2} S e CN{sup -} em meio aquoso

    Energy Technology Data Exchange (ETDEWEB)

    Correa, Luiz Augusto; Ferreira, Luiz Antonio [PETROBRAS/REPAR, Araucaria, PR (Brazil). Refinaria Presidente Getulio Vargas; Baptista, Walmar [PETROBRAS, Rio de Janeiro, RJ (Brazil). Centro de Pesquisas

    1998-07-01

    This paper presents the system for corrosion control in the equipment for gas separation in the catalytic cracking, developed by PETROBRAS, Brazil. The system uses hydrogen peroxide as a CN{sup -} neutralization agent.

  12. Evaluation of corrosive behavior of SAE 5155 by corrosion environment

    International Nuclear Information System (INIS)

    An, Jae Pil; Park, Keyung Dong

    2005-01-01

    In this study, the influence of shot peening and corrosive condition for corrosion property was investigated on immersed in 3.5% NaCl, 10% HNO 3 + 3% HF, 6% FeCl 3 . The immersion test was performed on two kinds of specimen. The immersion periods was performed 30days. Corrosion potential, weight loss were investigated from experimental results. From test results, the effect of shot peening on the corrosion was evaluated

  13. Microbiologically induced corrosion

    International Nuclear Information System (INIS)

    Stein, A.A.

    1988-01-01

    Biological attack is a problem that can affect all metallic materials in a variety of environments and systems. In the power industry, corrosion studies have focused on condensers and service water systems where slime, barnacles, clams, and other macro-organisms are easily detected. Efforts have been made to eliminate the effect of these organisms through the use of chlorination, backflushing, organic coating, or thermal shock. The objective is to maintain component performance by eliminating biofouling and reducing metallic corrosion. Recently, corrosion of power plant components by micro-organisms (bacteria) has been identified even in very clean systems. A system's first exposure to microbiologically induced corrosion (MIC) occurs during its first exposure to an aqueous environment, such as during hydrotest or wet layup. Corrosion of buried pipelines by sulfate-reducing bacteria has been studied by the petrochemical industry for years. This paper discusses various methods of diagnosing, monitoring, and controlling MIC in a variety of systems, as well as indicates areas where further study is needed

  14. Corrosion failure analysis as related to prevention of corrosion failures

    International Nuclear Information System (INIS)

    Suss, H.

    1977-10-01

    The factors and conditions which have contributed to many of the corrosion related service failures are discussed based on a review of actual case histories. The anti-corrosion devices which developed as a result of these failure analyses are reviewed, and the method which must be adopted and used to take advantage of the available corrosion prevention techniques is discussed

  15. Ensayo piloto de biorremediación de suelos contaminados por hidrocarburos. Fase ll

    Directory of Open Access Journals (Sweden)

    Gloria Lucía Camargo Millán

    2009-06-01

    Full Text Available  El estudio de la biodegradación de los hidrocarburos compuestos,altamente contaminantes y tóxicos, es de interéspara la descontaminación de ambientes afectados por derramesde petróleo. Aunque este proceso se presenta demanera natural, es demasiado lento, razón por la que sehace necesario el uso de técnicas de biorremediación parafacilitar la acción microbiana sobre los contaminantes. Anivel experimental este proceso se realiza por etapas o ensayos,ya sean de laboratorio, pilotos, de campo oimplementación. Previamente a este estudio se trabajó unaetapa a nivel de laboratorio, donde se observó la remociónde hidrocarburo en un suelo contaminado de manera inducida,aislándose bacterias capaces de su degradación, loque mostró que el proceso es factible. El presente estudiocorresponde a la etapa a nivel piloto, cuyo objetivo eracuantificar la tasa de remoción de hidrocarburo en muestrasde suelo contaminadas con crudo de castilla provenientede diez terrarios, a los cuales se les inoculó bacteriastotales y bacterias Pseudomonas aeruginosa.

  16. Corrosion testing facilities in India

    International Nuclear Information System (INIS)

    Viswanathan, R.; Subramanian, Venu

    1981-01-01

    Major types of corrosion tests, establishment of specifications on corrosion testing and scope of their application in practice are briefly described. Important organizations in the world which publish specifications/standards are listed. Indian organizations which undertake corrosion testing and test facilities available at them are also listed. Finally in an appendix, a comprehensive list of specifications relevant to corrosion testing is given. It is arranged under the headings: environmental testing, humidity tests, salt spray/fog tests, immersion tests, specification corrosion phenomena, (tests) with respect to special corrosion media, (tests) with respect to specific corrosion prevention methods, and specific corrosion tests using electrical and electrochemical methods (principles). Each entry in the list furnishes information about: nature of the test, standard number, and its specific application. (M.G.B.)

  17. Acid corrosion inhibitor

    Energy Technology Data Exchange (ETDEWEB)

    Chen, N G

    1964-04-28

    An acid corrosion inhibitor is prepared by a 2-stage vacuum evaporation of effluents obtained from the ammonia columns of the coking oven plant. The effluent, leaving a scrubber in which the phenols are removed at a temperature of 98$C, passes through a quartz filter and flows into a heated chamber in which it is used for preheating a solution circulating through a vacuum unit, maintaining the temperature of the solution at 55$ to 60$C. The effluent enters a large tank in which it is boiled at 55$ to 60$C under 635 to 640 mm Hg pressure. Double evaporation of this solution yields a very effective acid corrosion inhibitor. Its corrosion-preventing effect is 97.9% compared with 90.1% for thiourea and 88.5% for urotropin under identical conditions.

  18. Plastics for corrosion inhibition

    CERN Document Server

    Goldade, Victor A; Makarevich, Anna V; Kestelman, Vladimir N

    2005-01-01

    The development of polymer composites containing inhibitors of metal corrosion is an important endeavour in modern materials science and technology. Corrosion inhibitors can be located in a polymer matrix in the solid, liquid or gaseous phase. This book details the thermodynamic principles for selecting these components, their compatibility and their effectiveness. The various mechanisms of metal protection – barrier, inhibiting and electromechanical – are considered, as are the conflicting requirements placed on the structure of the combined material. Two main classes of inhibited materials (structural and films/coatings) are described in detail. Examples are given of structural plastics used in friction units subjected to mechano-chemical wear and of polymer films/coatings for protecting metal objects against corrosion.

  19. Corrosion Monitoring System

    Energy Technology Data Exchange (ETDEWEB)

    Dr. Russ Braunling

    2004-10-31

    The Corrosion Monitoring System (CMS) program developed and demonstrated a continuously on-line system that provides real-time corrosion information. The program focused on detecting pitting corrosion in its early stages. A new invention called the Intelligent Ultrasonic Probe (IUP) was patented on the program. The IUP uses ultrasonic guided waves to detect small defects and a Synthetic Aperture Focusing Technique (SAFT) algorithm to provide an image of the pits. Testing of the CMS demonstrated the capability to detect pits with dimensionality in the sub-millimeter range. The CMS was tested in both the laboratory and in a pulp and paper industrial plant. The system is capable of monitoring the plant from a remote location using the internet.

  20. Stochastic theory of fatigue corrosion

    Science.gov (United States)

    Hu, Haiyun

    1999-10-01

    A stochastic theory of corrosion has been constructed. The stochastic equations are described giving the transportation corrosion rate and fluctuation corrosion coefficient. In addition the pit diameter distribution function, the average pit diameter and the most probable pit diameter including other related empirical formula have been derived. In order to clarify the effect of stress range on the initiation and growth behaviour of pitting corrosion, round smooth specimen were tested under cyclic loading in 3.5% NaCl solution.

  1. Corrosion-resistant metal surfaces

    Science.gov (United States)

    Sugama, Toshifumi [Wading River, NY

    2009-03-24

    The present invention relates to metal surfaces having thereon an ultrathin (e.g., less than ten nanometer thickness) corrosion-resistant film, thereby rendering the metal surfaces corrosion-resistant. The corrosion-resistant film includes an at least partially crosslinked amido-functionalized silanol component in combination with rare-earth metal oxide nanoparticles. The invention also relates to methods for producing such corrosion-resistant films.

  2. Efectos protectores de la oleoiletanolamida en la neuroinflamación inducida por la administración de lipopolisacárido o por el consumo intensivo de alcohol

    OpenAIRE

    Antón Valadés, María

    2016-01-01

    La neuroinflamación es un fenómeno que contribuye a la progresión y agravamiento de enfermedades neurodegenerativas y neuropsiquiátricas, incluida la adicción a sustancias como el alcohol. Se han descrito acciones neuroprotectoras de mediadores lipídicos naturales derivados de la membrana celular, tales como la oleoiletanolamida, y su congénere la palmitoiletanolamida, ambos pertenecientes a la familia de las aciletanolamidas. Se desconoce con exactitud el potencial efecto terapéutico de esto...

  3. 78 FR 59652 - Certain Corrosion-Resistant Carbon Steel Flat Products From the Republic of Korea: Notice of...

    Science.gov (United States)

    2013-09-27

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-580-816] Certain Corrosion-Resistant... corrosion-resistant carbon steel flat products (``CORE'') from the Republic of Korea (``Korea''), pursuant... administrative review of the antidumping duty order on CORE from Korea covering the period of review (``POR'') of...

  4. 78 FR 59651 - Certain Corrosion-Resistant Carbon Steel Flat Products From the Republic of Korea: Notice of...

    Science.gov (United States)

    2013-09-27

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-580-816] Certain Corrosion-Resistant... duty order on certain corrosion-resistant carbon steel flat products (``CORE'') from the Republic of... covering the period of review (``POR'') of August 1, 2006 through July 31, 2007, with respect to the...

  5. Influence of the surgical manipulation of the colon in colonic induced carcinogenesis in rats Influencia de la manipulación quirúrgica del colon en la carcinogénesis cólica inducida en ratas

    Directory of Open Access Journals (Sweden)

    J. F. Noguera Aguilar

    2004-05-01

    1-2 dimetilhidrazina dihidrocloruro. Se identificaron los adenocarcinomas cólicos y se determinaron número de tumores, superficie tumoral y porcentaje de superficie tumoral. El análisis estadístico se realizó con modelos Anova de comparación de medias y con tablas de contingencia Chi cuadrado. Resultados: el número de tumores fue mayor en el grupo quirúrgico que en el control, apareciendo preferentemente alrededor del colon manipulado. La superficie y el porcentaje tumorales fueron mayores en el grupo quirúrgico que en el control, siendo mayores a su vez en el grupo con anastomosis frente al grupo con traumatismo cólico. Dentro de los grupos con anastomosis, presentó mayor superficie y porcentaje tumoral el grupo con adición de titanio frente al grupo con material reabsorbible. Conclusiones: la manipulación experimental del colon de la rata aumenta la carcinogénesis cólica farmacológicamente inducida. La creación de una anastomosis provoca un mayor incremento del proceso carcinogénico que la anastomosis simulada. Este proceso se ve además favorecido por la cantidad de material de sutura incluida en la anastomosis y por la naturaleza irreabsorbible de los materiales implantados en la línea anastomótica.

  6. Rhenium corrosion in chloride melts

    International Nuclear Information System (INIS)

    Stepanov, A.D.; Shkol'nikov, S.N.; Vetyukov, M.M.

    1989-01-01

    The results investigating rhenium corrosion in chloride melts containing sodium, potassium and chromium ions by a gravimetry potentials in argon atmosphere in a sealing quarth cell are described. Rhenium corrosion is shown to be rather considerable in melts containing CrCl 2 . The value of corrosion rate depending on temperature is determined

  7. Accelerated cyclic corrosion tests

    Directory of Open Access Journals (Sweden)

    Prošek T.

    2016-06-01

    Full Text Available Accelerated corrosion testing is indispensable for material selection, quality control and both initial and residual life time prediction for bare and painted metallic, polymeric, adhesive and other materials in atmospheric exposure conditions. The best known Neutral Salt Spray (NSS test provides unrealistic conditions and poor correlation to exposures in atmosphere. Modern cyclic accelerated corrosion tests include intermittent salt spray, wet and dry phases and eventually other technical phases. They are able to predict the material performance in service more correctly as documented on several examples. The use of NSS should thus be restricted for quality control.

  8. Achievments of corrosion science and corrosion protection technology

    International Nuclear Information System (INIS)

    Fontana, M.; Stehjl, R.

    1985-01-01

    Problems of corrosion-mechanical strength of metals, effect of corrosive media on creep characteristics are presented. New concepts of the mechanism of corrosion cracking and its relation to hydrogen embrittlement are described. Kinetics and mechanism of hydrogen embrittlement effect on the process of corrosion cracking of different steels and alloys are considered. The dependence of such types of failure on various structural factors is shown. Data on corrosion cracking of high-strength aluminium and titanium alloys, mechanism of the processes and protective methods are given

  9. Development of tubings 3 percent of CR with higher CO{sub 2} corrosion resistance for exploration and production of oil and gas; Desenvolvimento de 'tubings' 3 % cromo com maior resistencia a corrosao por CO{sub 2} para exploracao e producao de petroleo e gas

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Ricardo Nolasco de; Loureiro, Flavio Guerra; Ferreira, Marcelo Almeida Cunha [V e M do Brasil, Belo Horizonte, MG (Brazil); Coelho, Sonia Maria [Instituto Nacional de Tecnologia (INT), Rio de Janeiro, RJ (Brazil). Div. de Quimica; Baptista, Ilson Palmieri [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil). Centro de Pesquisas

    2008-07-01

    On of the most important issues of petroleum and gas industries is the corrosion of equipment for exploitation and production, due to its implications in the depreciation and operational costs, besides environmental, health and safety concerns. The CO{sub 2} corrosion is one of the main causes of failures in oil wells and one of available technological alternatives to its control is the increase in the steel chromium content. This work presents the development of tubings with chromium contents close to 3 %, for application in CO{sub 2} containing wells. The chemical analysis was designed in order to maximize chromium in solid solution meeting, at the same time, the mechanical properties of a API L 80. The evaluation of corrosion resistance was done through static and dynamic tests with p CO{sub 2} of 1b ar, pH of 4,0 and 5,0 and temperatures of 25, 50 and 70 deg C. In general, the steel with 3 % of chromium showed uniform corrosion approximately 3 times lower, besides crevice corrosion, pitting and polarization resistance were superior than that form reference steel, API L 80 type 1. The good results coming from laboratory incentives even more the run field tests, which started recently in Campos Basin PETROBRAS wells. (author)

  10. Síndrome metabólico y preeclampsia: los aportes realizados por el Instituto de Investigaciones de la Fundación Cardiovascular de Colombia Metabolic syndrome and pre-eclampsia: contributions realized by the research Institute of the Colombian Cardiovascular Foundation

    OpenAIRE

    Patricio López-Jaramillo; Federico Silva; Paul A Camacho; Lina P Pradilla; Ronald García; Christian Rueda-Clausen; Yalil Bracho; Sandra Silva; Ligia Rueda; Narella Rodríguez; Juan G Zarruk; Mayaris Mendoza; Mario Arenas; William Arenas; Isabel C Bolívar

    2006-01-01

    Durante los últimos años, el Instituto de Investigaciones de la Fundación Cardiovascular de Colombia ha centrado sus proyectos en el estudio de las diferencias en los mecanismos etiofisiopatológicos de la hipertensión inducida por el embarazo y del síndrome metabólico en poblaciones de países desarrollados y en vía de desarrollo, así como en el peso específico de los factores de riesgo que determinan la presentación de estas enfermedades. Los resultados obtenidos de las investigaciones realiz...

  11. Corrosion resistant cemented carbide

    International Nuclear Information System (INIS)

    Hong, J.

    1990-01-01

    This paper describes a corrosion resistant cemented carbide composite. It comprises: a granular tungsten carbide phase, a semi-continuous solid solution carbide phase extending closely adjacent at least a portion of the grains of tungsten carbide for enhancing corrosion resistance, and a substantially continuous metal binder phase. The cemented carbide composite consisting essentially of an effective amount of an anti-corrosion additive, from about 4 to about 16 percent by weight metal binder phase, and with the remaining portion being from about 84 to about 96 percent by weight metal carbide wherein the metal carbide consists essentially of from about 4 to about 30 percent by weight of a transition metal carbide or mixtures thereof selected from Group IVB and of the Periodic Table of Elements and from about 70 to about 96 percent tungsten carbide. The metal binder phase consists essentially of nickel and from about 10 to about 25 percent by weight chromium, the effective amount of an anti-corrosion additive being selected from the group consisting essentially of copper, silver, tine and combinations thereof

  12. Corrosion resistant steel

    International Nuclear Information System (INIS)

    Zubchenko, A.S.; Borisov, V.P.; Latyshev, V.B.

    1980-01-01

    Corrosion resistant steel for production of sheets and tubes containing C, Mn, Cr, Si, Fe is suggested. It is alloyed with vanadium and cerium for improving tensile properties and ductility. The steel can be melted by a conventional method in electric-arc or induction furnaces. The mentioned steel is intended to be used as a substitute for nickel-bearing austenitic steels

  13. Corrosion in seawater systems

    International Nuclear Information System (INIS)

    Henrikson, S.

    1988-01-01

    Highly alloyed stainless steels have been exposed to natural chlorinated and chlorine-free seawater at 35 deg. C. Simulated tube-tubesheet joints, weld joints and galvanic couples with titanium, 90/10 CuNi and NiAl bronze were tested and evaluated for corrosion. The corrosion rates of various anode materials - zinc, aluminium and soft iron - were also determined. Finally the risk of hydrogen embrittlement of tubes of ferritic stainless steels and titanium as a consequence of cathodic protection was studied. An attempt was also made to explain the cracking mechanism of the ferritic steels by means of transmission electron microscopy. One important conclusion of the project is that chlorinated seawater is considerably more corrosive to stainless steels than chlorine-free water, whereas chlorination reduces the rate of galvanic corrosion of copper materials coupled to stainless steels. Hydrogen embrittlement of ferritic stainless steels and titanium as a consequence of cathodic protection of carbon steel or cast iron in the same structure can be avoided by strict potentiostatic control of the applied potential. (author)

  14. Corrosion resistant composite materials

    International Nuclear Information System (INIS)

    Ul'yanin, E.A.

    1986-01-01

    Foundations for corrosion-resistant composite materials design are considered with account of components compatibility. Fibrous and lamellar composites with metal matrix, dispersion-hardened steels and alloys, refractory metal carbides-, borides-, nitrides-, silicides-based composites are described. Cermet compositions and fields of their application, such as protective coatings for operation in agressive media at high temperatures, are presented

  15. Development of Nb{sub 2}O{sub 5}|Cu composite as AISI 1020 steel thermal spray coating for protection against corrosion by soil in buried structures; Desenvolvimento e uso do composito de Nb{sub 2}O{sub 5}|Cu como revestimento aplicado por aspersao termica sobre o aco AISI 1020 para protecao contra a corrosao pelo solo em estruturas enterradas

    Energy Technology Data Exchange (ETDEWEB)

    Regis Junior, Oscar [Universidade Tecnologica Federal do Parana, Ponta Grossa, PR (Brazil). Dept. de Mecanica; Silva, Jose Maurilio da; Portella, Kleber Franke [Instituto de Tecnologia para o Desenvolvimento, Curitiba, PR (Brazil). Dept. de Pesquisa em Engenharia Civil; Paredes, Ramon Sigifredo Cortes, E-mail: regis@utfpr.edu.br [Universidade Federal do Parana, Curitiba, PR (Brazil). Dept. de Mecanica

    2012-07-01

    An Nb{sub 2}O|Cu corrosion-resistant coating was developed and applied onto AISI 1020 steel substrate by Powder Flame Spray. A galvanostatic electrochemical technique was employed, with and without ohmic drop, in four different soils (two corrosively aggressive and two less aggressive). Behavior of coatings in different soils was compared using a cathodic hydrogen reduction reaction (equilibrium potential, overvoltage and exchange current density) focusing on the effect of ohmic drop. Results allow recommendation of Nb{sub 2}O{sub 5}|Cu composite for use in buried structure protection. (author)

  16. Smart Coatings for Corrosion Protection

    Science.gov (United States)

    Calle, Luz Marina; Li, Wendy; Buhrow, Jerry W.; Johnsey, Marissa N.

    2016-01-01

    Nearly all metals and their alloys are subject to corrosion that causes them to lose their structural integrity or other critical functionality. It is essential to detect corrosion when it occurs, and preferably at its early stage, so that action can be taken to avoid structural damage or loss of function. Protective coatings are the most commonly used method of corrosion control. However, progressively stricter environmental regulations have resulted in the ban of many commercially available corrosion protective coatings due to the harmful effects of their solvents or corrosion inhibitors. This work concerns the development of a multifunctional, smart coating for the autonomous control of corrosion. This coating is being developed to have the inherent ability to detect the chemical changes associated with the onset of corrosion and respond autonomously to indicate it and control it.

  17. ¿Hay un mal en morir? Consideraciones éticas y jurídicas sobre la muerte inducida

    Directory of Open Access Journals (Sweden)

    ALEJANDRA ZÚÑIGA F.

    2011-01-01

    Full Text Available Se analizan los dilemas morales asociados a la muerte, para reflexionar sobre los interrogantes que surgen al calificarla como un hecho banal desde la perspectiva de quien muere. Se estudian, además, las consecuencias éticas y jurídicas de reconocer autonomía moral a quienes deciden, en circunstancias extremas, tomar por sí mismos la decisión de cuándo y cómo morir.

  18. Corrosion potential analysis system

    Science.gov (United States)

    Kiefer, Karl F.

    1998-03-01

    Many cities in the northeastern U.S. transport electrical power from place to place via underground cables, which utilize voltages from 68 kv to 348 kv. These cables are placed in seamless steel pipe to protect the conductors. These buried pipe-type-cables (PTCs) are carefully designed and constantly pressurized with transformer oil to prevent any possible contamination. A protective coating placed on the outside diameter of the pipe during manufacture protects the steel pipe from the soil environment. Notwithstanding the protection mechanisms available, the pipes remain vulnerable to electrochemical corrosion processes. If undetected, corrosion can cause the pipes to leak transformer oil into the environment. These leaks can assume serious proportions due to the constant pressure on the inside of the pipe. A need exists for a detection system that can dynamically monitor the corrosive potential on the length of the pipe and dynamically adjust cathodic protection to counter local and global changes in the cathodic environment surrounding the pipes. The northeastern United States contains approximately 1000 miles of this pipe. This milage is critical to the transportation and distribution of power. So critical, that each of the pipe runs has a redundant double running parallel to it. Invocon, Inc. proposed and tested a technically unique and cost effective solution to detect critical corrosion potential and to communicate that information to a central data collection and analysis location. Invocon's solution utilizes the steel of the casing pipe as a communication medium. Each data gathering station on the pipe can act as a relay for information gathered elsewhere on the pipe. These stations must have 'smart' network configuration algorithms that constantly test various communication paths and determine the best and most power efficient route through which information should flow. Each network station also performs data acquisition and analysis tasks that ultimately

  19. The effect of corrosion on stained glass windows

    Directory of Open Access Journals (Sweden)

    Laissner, Johanna

    1996-06-01

    Full Text Available Stained glass windows belong to the most important cultural heritage of Europe. Within the last decades a disastrous deterioration took place. The wonderful stained glass windows and their glass paintings as pieces of art are acutely menaced by environmental corrosive influences. This corrosion process is a very complex reaction which is not only influenced by temperature and humidity changes but also by gaseous pollutants like sulfur dioxide, nitrogen oxides or ozone, by dust and air, microorganisms as well as synergetic interactions. Strongly affected by these environmental attacks are medieval stained glasses due to their chemical composition. They have a low content in silica and high contents of modifier ions (e.g. potassium and calcium. The corrosion phenomena can range from predominantly pitting on the surface to the formation of thick corrosion crusts which are turning the panel opaque and thus reducing strongly the transparency of the windows. In order to set up a conservation and restoration concept, it is necessary to know about the environmental conditions to which the stained glass windows are exposed. For this purpose very corrosion sensitive model glasses (so called glass sensors were developed which have a similar chemical composition as historic stained glasses. They exhibit the same corrosion reactions but react much faster, and are now widely used to estimate corrosive stresses on stained glass windows to give basic information about the corrosive impacts which work on the historic glasses. In this paper principle corrosion mechanisms of stained glass windows and their enhancing factors are discussed. For the evaluation of the environmental impact, the application of glass sensors is demonstrated.

    Las vidrieras coloreadas pertenecen al legado cultural más importante de Europa. En las últimas décadas se ha producido en ellas un desastroso deterioro. Las maravillosas vidrieras coloreadas y sus policromías est

  20. El péptido ? A [25-35] y el hierro promueven apoptosis en linfocitos por un mecanismo de estrés oxidativo: contribución del H202,, caspasa 3, fn- kb, p53 y c-Jun

    Directory of Open Access Journals (Sweden)

    Marlene Jiménez

    2001-04-01

    Full Text Available El depósito del beta-amiloide (βA en las placas neuríticas es
    uno de los principales marcadores neuropatológicos de la enfermedad de Alzheimer (EA. Estudios in vitro han demostrado que el fragmento βA25-35, el cual contiene la secuencia funcionalmente citotóxica del péptido amiloide, induce neurotoxicidad y muerte celular por apoptosis (1. A pesar de las intensas investigaciones, no se ha dado una descripción completa de la cascada de eventos moleculares que conducen a muerte inducida por βA25-35 en un modelo celular único. Por lo tanto, nuestro objetivo principal es evidenciar una cascada de eventos moleculares ordenados inducidos por el bA25-35 y el hierro en un modelo celular.

  1. Mobile evaporator corrosion test results

    International Nuclear Information System (INIS)

    Rozeveld, A.; Chamberlain, D.B.

    1997-05-01

    Laboratory corrosion tests were conducted on eight candidates to select a durable and cost-effective alloy for use in mobile evaporators to process radioactive waste solutions. Based on an extensive literature survey of corrosion data, three stainless steel alloys (304L, 316L, AL-6XN), four nickel-based alloys (825, 625, 690, G-30), and titanium were selected for testing. The corrosion tests included vapor phase, liquid junction (interface), liquid immersion, and crevice corrosion tests on plain and welded samples of candidate materials. Tests were conducted at 80 degrees C for 45 days in two different test solutions: a nitric acid solution. to simulate evaporator conditions during the processing of the cesium ion-exchange eluant and a highly alkaline sodium hydroxide solution to simulate the composition of Tank 241-AW-101 during evaporation. All of the alloys exhibited excellent corrosion resistance in the alkaline test solution. Corrosion rates were very low and localized corrosion was not observed. Results from the nitric acid tests showed that only 316L stainless steel did not meet our performance criteria. The 316L welded interface and crevice specimens had rates of 22.2 mpy and 21.8 mpy, respectively, which exceeds the maximum corrosion rate of 20 mpy. The other welded samples had about the same corrosion resistance as the plain samples. None of the welded samples showed preferential weld or heat-affected zone (HAZ) attack. Vapor corrosion was negligible for all alloys. All of the alloys except 316L exhibited either open-quotes satisfactoryclose quotes (2-20 mpy) or open-quotes excellentclose quotes (<2 mpy) corrosion resistance as defined by National Association of Corrosion Engineers. However, many of the alloys experienced intergranular corrosion in the nitric acid test solution, which could indicate a susceptibility to stress corrosion cracking (SCC) in this environment

  2. Microbiological corrosion in low carbon steels; Corrosion microbiologica en aceros de bajo carbono

    Energy Technology Data Exchange (ETDEWEB)

    Medina-Custodio, O; Ortiz-Prado, A; Jacobo-Armendariz, V. H; Schouwenaars-Franssens, R [Universidad Nacional Autonoma de Mexico, Mexico, D.F. (Mexico)]. E-mail: medina_1979@yahoo.com; armandoo@servidor.unam.mx; vjacobo@dgapa.unam.mx; raf_schouweenaars@yahoo.com

    2009-01-15

    The Microbiologically Induced Corrosion affects several industries, such as oil industry where it is estimated that 20% to 30% pipes failures are related with microorganism. The chemical reactions generate ions transfer, this validate the use of electrochemical technique for its analysis. Coupons submerged in a nutritional medium with presence and absence of three different microorganisms during two periods, 48 hours and 28 days were studied. Polarization resistance (Rp) and Electrochemical Impedance Spectroscopy (EIS) techniques were applied to determine the corrosively of the systems. The results show a greater corrosive effect of abiotic systems, this indicates a microorganisms protection effect to the metal, opposite to the first hypothesis. This result was ratified observing surface coupons by using Scanning Electron Microscopy (SEM) technique. A possible mechanism based on Evans - Tafel graph is proposed to explain inhibitor microorganism effect. [Spanish] La corrosion microbiologica es un tipo comun de deterioro que afecta diversas industrias, una de ellas es la petrolera en la que se estiman que el 20% o 30% de fallas en las tuberias de trasporte de hidrocarburos es favorecida por microorganismos. Las reacciones quimicas que sustentan estos, generan transferencia de iones, lo que justifica el empleo de tecnicas electroquimicas para su analisis. En este trabajo, se estudiaron probetas de acero de bajo carbono SAE 1018, sumergidas en un medio nutritivo rico en cloruros en presencia y ausencia de tres diferentes cargas microbianas, en tiempos de exposicion de 48 horas y 28 dias. Se realizaron ensayos de resistencia a la polarizacion (Rp) y espectroscopia de impedancia electroquimica (EIS) para determinar el efecto corrosivo de los diferentes sistemas. Los resultados muestran que el medio abiotico causa el mayor efecto corrosivo, lo que indica un efecto protector de los microorganismos al metal contradiciendo la hipotesis inicialmente propuesta. La observacion

  3. Corrosion Evaluation and Corrosion Control of Steam Generators

    International Nuclear Information System (INIS)

    Maeng, W. Y.; Kim, U. C.; Sung, K. W.; Na, J. W.; Lee, Y. H.; Lee, D. H.; Kim, K. M.

    2008-06-01

    Corrosion damage significantly influences the integrity and efficiency of steam generator. Corrosion problems of steam generator are unsolved issues until now even though much effort is made around world. Especially the stress corrosion cracking of heat exchange materials is the first issue to be solved. The corrosion protection method of steam generator is important and urgent for the guarantee of nuclear plant's integrity. The objectives of this study are 1) to evaluate the corrosion properties of steam generator materials, 2) to optimize the water chemistry of steam generator and 3) to develop the corrosion protection method of primary and secondary sides of steam generator. The results will be reflected to the water chemistry guideline for improving the integrity and efficiency of steam generator in domestic power plants

  4. Stress corrosion and corrosion fatigue crack growth monitoring in metals

    International Nuclear Information System (INIS)

    Senadheera, T.; Shipilov, S.A.

    2003-01-01

    Environmentally assisted cracking (including stress corrosion cracking and corrosion fatigue) is one of the major causes for materials failure in a wide variety of industries. It is extremely important to understand the mechanism(s) of environmentally assisted crack propagation in structural materials so as to choose correctly from among the various possibilities-alloying elements, heat treatment of steels, parameters of cathodic protection, and inhibitors-to prevent in-service failures due to stress corrosion cracking and corrosion fatigue. An important step towards understanding the mechanism of environmentally assisted crack propagation is designing a testing machine for crack growth monitoring and that simultaneously provides measurement of electrochemical parameters. In the present paper, a direct current (DC) potential drop method for monitoring crack propagation in metals and a testing machine that uses this method and allows for measuring electrochemical parameters during stress corrosion and corrosion fatigue crack growth are described. (author)

  5. Corrosion Evaluation and Corrosion Control of Steam Generators

    Energy Technology Data Exchange (ETDEWEB)

    Maeng, W. Y.; Kim, U. C.; Sung, K. W.; Na, J. W.; Lee, Y. H.; Lee, D. H.; Kim, K. M

    2008-06-15

    Corrosion damage significantly influences the integrity and efficiency of steam generator. Corrosion problems of steam generator are unsolved issues until now even though much effort is made around world. Especially the stress corrosion cracking of heat exchange materials is the first issue to be solved. The corrosion protection method of steam generator is important and urgent for the guarantee of nuclear plant's integrity. The objectives of this study are 1) to evaluate the corrosion properties of steam generator materials, 2) to optimize the water chemistry of steam generator and 3) to develop the corrosion protection method of primary and secondary sides of steam generator. The results will be reflected to the water chemistry guideline for improving the integrity and efficiency of steam generator in domestic power plants.

  6. Scanning reference electrode techniques in localized corrosion

    International Nuclear Information System (INIS)

    Isaacs, H.S.; Vyas, B.

    1979-04-01

    The principles, advantages, and implementations of scanning reference electrode techniques are reviewed. Data related to pitting, intergranular corrosion, welds and stress corrosion cracking are presented. The technique locates the position of localized corrosion and can be used to monitor the development of corrosion and changes in the corrosion rate under a wide range of conditions

  7. Corrosion control for low-cost reliability

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    This conference was held September 19-24, 1993 in Houston, Texas to provide a forum for exchange of state-of-the-art information on corrosion. Topics of interest focus on the following: atmospheric corrosion; chemical process industry corrosion; high temperature corrosion; and corrosion of plant materials. Individual papers have been processed separately for inclusion in the appropriate data bases

  8. CHECWORKS integrated software for corrosion control

    International Nuclear Information System (INIS)

    Schefski, C.; Pietralik; Hazelton, T.

    1997-01-01

    CHECWORKS, a comprehensive software package for managing Flow-Accelerated Corrosion (FAC, also called erosion-corrosion and flow-assisted corrosion) concerns, is expanding to include other systems and other aspects of corrosion control in CANDU reactors. This paper will outline CHECWORKS applications at various CANDU stations and further plans for CHECWORKS to become a code for comprehensive corrosion control management. (author)

  9. Anti-Corrosion Coating

    Science.gov (United States)

    1986-01-01

    SuperSpan RM 8000 is an anti-corrosion coating which effectively counteracts acid degradation, abrasive wear, and cracking in power industry facilities. It was developed by RM Industrial Products Company, Inc. with NERAC assistance. It had previously been necessary to shut down plants to repair or replace corroded duct-work in coal burning utilities. NASA-developed technology was especially useful in areas relating to thermoconductivity of carbon steel and the bonding characteristics of polymers. The product has sold well.

  10. Corrosion in power engineering

    International Nuclear Information System (INIS)

    1988-03-01

    The proceedings contain the full texts of 25 papers of which 10 fall under the INIS Subject Scope. They concern the problems of corrosion in WWER type nuclear power plants. The topics include structural materials and equipment of the primary and the secondary circuits of nuclear power plants, components used in disposal of spent nuclear fuel, sodium valves for fast reactors and basic study of the properties of materials used in nuclear power. (Z.M.). 12 figs., 6 tabs., 46 refs

  11. Air corrosion in storing

    International Nuclear Information System (INIS)

    Mazaudier, F.; Feron, D.; Baklouti, M.; Midoux, N.

    2001-01-01

    The air corrosiveness of a radioactive waste package has been estimated in a store inside which the environmental conditions are supposed to be rather close to the outside ones. It is expressed according to the ISO 9223 standard, from the humidification value and the amounts of sulfur dioxide and chlorine ions. A computer code has been perfected too; the thermal behaviour of the package can then been determined. (O.M.)

  12. Corrosion Protection of Aluminum

    Science.gov (United States)

    Dalrymple, R. S.; Nelson, W. B.

    1963-07-01

    Treatment of aluminum-base metal surfaces in an autoclave with an aqueous chromic acid solution of 0.5 to 3% by weight and of pH below 2 for 20 to 50 hrs at 160 to 180 deg C produces an extremely corrosion-resistant aluminum oxidechromium film on the surface. A chromic acid concentration of 1 to 2% and a pH of about 1 are preferred.

  13. Corrosion of beryllium oxide

    International Nuclear Information System (INIS)

    Elston, J.; Caillat, R.

    1958-01-01

    Data are reported on the volatilization rate of beryllium oxide in moist air depending on temperature and water vapour concentration. They are concerned with powder samples or sintered shapes of various densities. For sintered samples, the volatilization rate is very low under the following conditions: - temperature: 1300 deg. C, - water vapour concentration in moist air: 25 g/m 3 , - flow rate: 12 I/hour corresponding to a speed of 40 m/hour on the surface of the sample. For calcinated powders (1300 deg. C), grain growth has been observed under a stream of moist air at 1100 deg. C. For instance, grain size changes from 0,5 to at least 2 microns after 500 hours of exposure at this temperature. Furthermore, results data are reported on corrosion of sintered beryllium oxide in pressurized water. At 250 deg. C, under a pressure of 40 kg/cm 2 water is very slightly corrosive; however, internal strains are revealed. Finally, some features on the corrosion in liquid sodium are exposed. (author) [fr

  14. Zircaloy-4 corrosion in PWR's

    International Nuclear Information System (INIS)

    Fyfitch, S.; Smalley, W.R.; Roberts, E.

    1985-01-01

    Zircaloy-4 waterside corrosion has been studied extensively in the nuclear industry for a number of years. Following the early crud-related corrosion failures in the Saxton test reactor, Westinghouse undertook numerous programs to minimize crud deposition on fuel rods in power reactors through primary coolant chemistry control. Modern plants today are operating with improved coolant chemistry guidelines, and crud deposition levels are very low in proportion to earlier experience. Zircaloy-4 corrosion under a variety of coolant chemistry, heat flux and exposure conditions has been studied extensively. Experience to date, even in relatively high coolant temperature plants, has indicated that -for both fuel cladding and structural components- Zircaloy-4 waterside corrosion performance has been excellent. Recognizing future industry trends, however, which will result in Zircaloy-4 being subjected to ever increasing corrosion duties, Westinghouse will continue accumulating Zircaloy-4 corrosion experience in large power plants. 13 refs.

  15. Nuclear corrosion science and engineering

    CERN Document Server

    2012-01-01

    Understanding corrosion mechanisms, the systems and materials they affect, and the methods necessary for accurately measuring their incidence is of critical importance to the nuclear industry for the safe, economic and competitive running of its plants. This book reviews the fundamentals of nuclear corrosion. Corrosion of nuclear materials, i.e. the interaction between these materials and their environments, is a major issue for plant safety as well as for operation and economic competitiveness. Understanding these corrosion mechanisms, the systems and materials they affect, and the methods to accurately measure their incidence is of critical importance to the nuclear industry. Combining assessment techniques and analytical models into this understanding allows operators to predict the service life of corrosion-affected nuclear plant materials, and to apply the most appropriate maintenance and mitigation options to ensure safe long term operation. This book critically reviews the fundamental corrosion mechani...

  16. Pipe Lines – External Corrosion

    Directory of Open Access Journals (Sweden)

    Dan Babor

    2008-01-01

    Full Text Available Two areas of corrosion occur in pipe lines: corrosion from the medium carried inside the pipes; corrosion attack upon the outside of the pipes (underground corrosion. Electrolytic processes are also involved in underground corrosion. Here the moisture content of the soil acts as an electrolyte, and the ions required to conduct the current are supplied by water-soluble salts (chlorides, sulfates, etc. present in the soil. The nature and amount of these soluble materials can vary within a wide range, which is seen from the varying electrical conductivity and pH (varies between 3 and 10. Therefore the characteristics of a soil will be an important factor in under-ground corrosion.

  17. Accelerated Stress-Corrosion Testing

    Science.gov (United States)

    1986-01-01

    Test procedures for accelerated stress-corrosion testing of high-strength aluminum alloys faster and provide more quantitative information than traditional pass/fail tests. Method uses data from tests on specimen sets exposed to corrosive environment at several levels of applied static tensile stress for selected exposure times then subsequently tensile tested to failure. Method potentially applicable to other degrading phenomena (such as fatigue, corrosion fatigue, fretting, wear, and creep) that promote development and growth of cracklike flaws within material.

  18. Corrosion of fuel assembly materials

    International Nuclear Information System (INIS)

    Noe, M.; Frejaville, G.; Beslu, P.

    1985-08-01

    Corrosion of zircaloy-4 is reviewed in relation with previsions of improvement in PWRs performance: higher fuel burnup; increase coolant temperature, implying nucleate boiling on the hot clad surfaces; increase duration of the cycle due to load-follow operation. Actual knowledge on corrosion rates, based partly on laboratory tests, is insufficient to insure that external clad corrosion will not constitute a limitation to these improvements. Therefore, additional testing within representative conditions is felt necessary [fr

  19. Corrosion Monitors for Embedded Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, Alex L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Pfeifer, Kent B. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Casias, Adrian L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Howell, Stephen W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Sorensen, Neil R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Missert, Nancy A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-05-01

    We have developed and characterized novel in-situ corrosion sensors to monitor and quantify the corrosive potential and history of localized environments. Embedded corrosion sensors can provide information to aid health assessments of internal electrical components including connectors, microelectronics, wires, and other susceptible parts. When combined with other data (e.g. temperature and humidity), theory, and computational simulation, the reliability of monitored systems can be predicted with higher fidelity.

  20. Luxación témporo-mandibular recurrente y secundaria a distonía por antipsicóticos.

    OpenAIRE

    Cruzado, Lizardo; Núñez-Moscoso, Patricia; Garibay-Huamaní, Mercibel; Villar-Salas, Alicia

    2016-01-01

    La distonía aguda inducida por antipsicóticos sigue siendo una patología frecuente en los servicios de emergencia psiquiátrica. Sin embargo, la luxación de la articulación témporo-mandibular, como secuela de distonía oromandibular, es una presentación inusual dentro de esta casuística. Presentamos el caso de una paciente mujer de 20 años de edad, quien recibió haloperidol intramuscular tras sendas crisis de agitación psicomotriz y persistencia de riesgo suicida, y que luego desarrolló distoní...

  1. Influencia mutua de la deformación y composición química sobre la precipitación inducida en aceros microaleados

    Directory of Open Access Journals (Sweden)

    Quispe, A.

    2005-12-01

    Full Text Available By means of torsion tests and applying the "back extrapolation" method, the static recrystallization kinetics in microalloyed steels with vanadium (V, niobium (Nb and titanium (Ti has been determined and, recrystallization-precipitation-time-temperature (RPTT diagrams have been plotted also graphically, which show the Recrystallization- Precipitation interaction. These diagrams show that the effect of the deformation on the precipitation kinetics depends of the microalloy content. In this sense, a new expression is proposed to relate the influence of the deformation and the chemical composition on the minimum incubation of the precipitation kinetics.

    Mediante ensayos de torsión y usando el método back extrapolation se ha determinado la cinética de recristalización estática de aceros microaleados con vanadio (V, niobio (Nb y titanio (Ti y, a partir de las mismas, ha sido posible dibujar los diagramas recristalizaciónprecipitación- tiempo-temperatura (RPTT, que muestran gráficamente la interacción recristalización-precipitación. Estos diagramas muestran que el efecto de la deformación en la cinética de precipitación depende del contenido de microaleante. En este sentido, se propone una nueva expresión para relacionar la influencia de la deformación y del contenido de microaleante sobre el periodo mínimo de incubación de la precipitación inducida.

  2. Evaluation of steel corrosion by numerical analysis

    OpenAIRE

    Kawahigashi, Tatsuo

    2017-01-01

    Recently, various non-destructive and numerical methods have been used and many cases of steel corrosion are examined. For example, methods of evaluating corrosion through various numerical methods and evaluating macrocell corrosion and micro-cell corrosion using measurements have been proposed. However, there are few reports on estimating of corrosion loss with distinguishing the macro-cell and micro-cell corrosion and with resembling an actuality phenomenon. In this study, for distinguishin...

  3. Corrosion and stress corrosion cracking in supercritical water

    Science.gov (United States)

    Was, G. S.; Ampornrat, P.; Gupta, G.; Teysseyre, S.; West, E. A.; Allen, T. R.; Sridharan, K.; Tan, L.; Chen, Y.; Ren, X.; Pister, C.

    2007-09-01

    Supercritical water (SCW) has attracted increasing attention since SCW boiler power plants were implemented to increase the efficiency of fossil-based power plants. The SCW reactor (SCWR) design has been selected as one of the Generation IV reactor concepts because of its higher thermal efficiency and plant simplification as compared to current light water reactors (LWRs). Reactor operating conditions call for a core coolant temperature between 280 °C and 620 °C at a pressure of 25 MPa and maximum expected neutron damage levels to any replaceable or permanent core component of 15 dpa (thermal reactor design) and 100 dpa (fast reactor design). Irradiation-induced changes in microstructure (swelling, radiation-induced segregation (RIS), hardening, phase stability) and mechanical properties (strength, thermal and irradiation-induced creep, fatigue) are also major concerns. Throughout the core, corrosion, stress corrosion cracking, and the effect of irradiation on these degradation modes are critical issues. This paper reviews the current understanding of the response of candidate materials for SCWR systems, focusing on the corrosion and stress corrosion cracking response, and highlights the design trade-offs associated with certain alloy systems. Ferritic-martensitic steels generally have the best resistance to stress corrosion cracking, but suffer from the worst oxidation. Austenitic stainless steels and Ni-base alloys have better oxidation resistance but are more susceptible to stress corrosion cracking. The promise of grain boundary engineering and surface modification in addressing corrosion and stress corrosion cracking performance is discussed.

  4. Archaeological analogs and corrosion; Analogues archeologiques et corrosion

    Energy Technology Data Exchange (ETDEWEB)

    David, D

    2008-07-01

    In the framework of the high level and long life radioactive wastes disposal deep underground, the ANDRA built a research program on the material corrosion. In particular they aim to design containers for a very long time storage. Laboratory experiments are in progress and can be completed by the analysis of metallic archaeological objects and their corrosion after hundred years. (A.L.B.)

  5. Phytochemicals as Green Corrosion Inhibitors in Various Corrosive ...

    African Journals Online (AJOL)

    There is an intensive effort underway to develop new plant origin corrosion inhibitors for metal subjected to various environmental conditions. These efforts have been motivated by the desire to replace toxic inhibitors used for mitigation of corrosion of various metals and alloys in aqueous solutions. Plants represent a class ...

  6. Shadow Corrosion Mechanism of Zircaloy

    International Nuclear Information System (INIS)

    Ullberg, Mats; Lysell, Gunnar; Nystrand, Ann-Charlotte

    2004-02-01

    Local corrosion enhancement appears on zirconium-base alloys in-core in boiling water reactors when the zirconium alloy is in close proximity to another metal. The visual appearance often resembles a shadow of the other component. The phenomenon is therefore referred to as 'shadow corrosion'. Shadow corrosion has been known for more than 25 years. Mechanisms based on either galvanic corrosion or local radiolysis effects have been proposed as explanations. Both types of mechanism have seemed to explain some facets of the phenomenon. Normally, shadow corrosion is of no practical significance. However, an enhanced and potentially serious form of shadow corrosion was discovered in 1996. This discovery stimulated new experiments that fully supported neither of the longstanding theories. Thus, there is till now no generally accepted understanding of the shadow corrosion phenomenon. The aim of the present investigation was to analyse the available data and to identify, if possible, a plausible mechanism of shadow corrosion. It was found that the experimental evidence is, with a few exceptions, remarkably consistent with a galvanic mechanism. The main exception is that shadow corrosion may occur also when the two metals are nominally electrically insulated. One way to account for the main exception could be to invoke the effect of photoconductivity. Photoconductivity results when a semiconductor or an insulator is irradiated with photons of UV or higher energy. The photons elevate electrons from the valence band to the conduction band, thereby raising the electron conductivity of the solid. In particular, photoconductivity lowers the electrical resistance of the normally insulating oxide on zirconium base alloys. Photoconductivity therefore also has the potential to explain why shadow corrosion is only seen in, or in proximity to, a nuclear reactor core. The suggested mechanism of shadow corrosion can be tested in a reasonably simple experiment in a research reactor

  7. Efecto citoprotector y antisecretor del aceite de Copaifera officinalis en lesiones gástricas inducidas en ratas

    Directory of Open Access Journals (Sweden)

    Jorge Arroyo

    2009-06-01

    Full Text Available Objetivos: Demostrar el efecto gastroprotector del aceite de Copaifera officinalis usando indometacina y ligadura de píloro en ratas. Diseño: Estudio preclínico. Lugar: Facultades de Medicina, de Farmacia y Bioquímica. Universidad Nacional Mayor de San Marcos, Lima, Perú. Material biológico: Ratas y aceite de copaiba. Intervenciones: Se colectó el aceite de copaiba en Ucayali, Pucallpa. La citoproteccción fue evaluada con indometacina, considerando un grupo control normal, indometacina, grupos de aceite de copaiba y omeprazol. Las lesiones de la mucosa gástrica fueron calificadas como las compatibles con necrosis local (tejido no viable, hiperemia, enrojecimiento presente y hemorragia, empleando la escala de puntaje observacional; y la úlcera, según la escala de Macallister modificado. El ensayo de antisecreción fue realizado por el modelo de ligadura del píloro, en el que 24 ratas albinas fueron divididas al azar en 3 grupos; un control, otro de aceite de copaiba 40mg/kg y un tercero de omeprazol 10 mg/kg. Después de 4 horas de ligazón, fueron sacrificados, extrayéndose los estómagos; con mucho cuidado se midió el volumen y se determinó el pH de la secreción gástrica, por potenciometría. Se realizó evaluación histopatológica según Devi. Principales medidas de resultados: Lesiones ulcerosas. Resultados: Los resultados indicaron 100% de efecto citoprotector con el aceite de copaiba y de 97,8% para el omeprazol (p<0,0001, ratificado con los hallazgos histopatológicos; la disminución del volumen de secreción fue 79,4% para omeprazol y 42,8% para el aceite de copaiba (p<0,001, con incremento del pH. Conclusiones: En condiciones experimentales, el aceite de copaiba fue efectivo como agente gastroprotector en ratas con inducción de úlcera gástrica.

  8. General Corrosion and Localized Corrosion of Waste Package Outer Barrier

    Energy Technology Data Exchange (ETDEWEB)

    K.G. Mon

    2004-10-01

    The waste package design for the License Application is a double-wall waste package underneath a protective drip shield (BSC 2004 [DIRS 168489]; BSC 2004 [DIRS 169480]). The purpose and scope of this model report is to document models for general and localized corrosion of the waste package outer barrier (WPOB) to be used in evaluating waste package performance. The WPOB is constructed of Alloy 22 (UNS N06022), a highly corrosion-resistant nickel-based alloy. The inner vessel of the waste package is constructed of Stainless Steel Type 316 (UNS S31600). Before it fails, the Alloy 22 WPOB protects the Stainless Steel Type 316 inner vessel from exposure to the external environment and any significant degradation. The Stainless Steel Type 316 inner vessel provides structural stability to the thinner Alloy 22 WPOB. Although the waste package inner vessel would also provide some performance for waste containment and potentially decrease the rate of radionuclide transport after WPOB breach before it fails, the potential performance of the inner vessel is far less than that of the more corrosion-resistant Alloy 22 WPOB. For this reason, the corrosion performance of the waste package inner vessel is conservatively ignored in this report and the total system performance assessment for the license application (TSPA-LA). Treatment of seismic and igneous events and their consequences on waste package outer barrier performance are not specifically discussed in this report, although the general and localized corrosion models developed in this report are suitable for use in these scenarios. The localized corrosion processes considered in this report are pitting corrosion and crevice corrosion. Stress corrosion cracking is discussed in ''Stress Corrosion Cracking of the Drip Shield, the Waste Package Outer Barrier, and the Stainless Steel Structural Material'' (BSC 2004 [DIRS 169985]).

  9. Corrosion mapping in pipelines

    International Nuclear Information System (INIS)

    Zscherpel, U.; Alekseychuk, O.; Bellon, C.; Ewert, U.; Rost, P.; Schmid, M.

    2002-01-01

    In a joint research project, BASF AG and BAM analyzed the state of the art of tangential radiography of pipes and developed more efficient methods of evaluation. Various PC applications were developed and tested: 1. A program for routine evaluation of digital radiographic images. 2. 3D simulation of the tangential projection of pipes for common radiation sources and various different detectors. 3. Preliminary work on combined evaluation of digital projections and wall thickness changes in radiation direction resulted in a new manner of image display, i.e. the so-called 'corrosion mapping', in which the wall thickness is displayed as a 2D picture above the pipe surface [de

  10. Microbiologically Influenced Corrosion

    Science.gov (United States)

    2015-11-05

    high in water content, are less corrosive owing to their elevated viscosity and resulting low conductivity (᝺-7 S/cm) [30]. Asphaltenes and resins...wet surface to a water-wet surface. Sludge deposits are combinations of hydrocarbons, sand, clay , corTosion prod- ucts, and biomass that can reach 50...fine clay sun·ounded by a film of water. Under low flow conditions, these particles precipitate and form a sludge deposit. 27.4 TESTING 27 .4.1 A

  11. Corrosion of Ceramic Materials

    Science.gov (United States)

    Opila, Elizabeth J.; Jacobson, Nathan S.

    1999-01-01

    Non-oxide ceramics are promising materials for a range of high temperature applications. Selected current and future applications are listed. In all such applications, the ceramics are exposed to high temperature gases. Therefore it is critical to understand the response of these materials to their environment. The variables to be considered here include both the type of ceramic and the environment to which it is exposed. Non-oxide ceramics include borides, nitrides, and carbides. Most high temperature corrosion environments contain oxygen and hence the emphasis of this chapter will be on oxidation processes.

  12. Corrosion management in nuclear industry

    International Nuclear Information System (INIS)

    Kamachi Mudali, U.

    2012-01-01

    Corrosion is a major degradation mechanism of metals and alloys which significantly affects the global economy with an average loss of 3.5% of GDP of several countries in many important industrial sectors including chemical, petrochemical, power, oil, refinery, fertilizer etc. The demand for higher efficiency and achieving name plate capacity, in addition to ever increasing temperatures, pressures and complexities in equipment geometry of industrial processes, necessitate utmost care in adopting appropriate corrosion management strategies in selecting, designing, fabricating and utilising various materials and coatings for engineering applications in industries. Corrosion control and prevention is an important focus area as the savings achieved from practicing corrosion control and prevention would bring significant benefits to the industry. Towards this, advanced corrosion management strategies starting from design, manufacturing, operation, maintenance, in-service inspection and online monitoring are essential. At the Indira Gandhi Centre for Atomic Research (IGCAR) strategic corrosion management efforts have been pursued in order to provide solutions to practical problems emerging in the plants, in addition to innovative efforts to provide insight into mechanism and understanding of corrosion of various engineering materials and coatings. In this presentation the author highlights how the nuclear industry benefited from the practical approach to successful corrosion management, particularly with respect to fast breeder reactor programme involving both reactor and associated reprocessing plants. (author)

  13. New technologies - new corrosion problems

    International Nuclear Information System (INIS)

    Heitz, E.

    1994-01-01

    Adequate resistance of materials to corrosion is equally important for classical and for new technologies. This article considers the economic consequences of corrosion damage and, in addition to the long-known GNP orientation, presents a new approach to the estimation of the costs of corrosion and corrosion protection via maintenance and especially corrosion-related maintenance. The significance of ''high-tech'', ''medium-tech'' and ''low-tech'' material and corrosion problems is assessed. Selected examples taken from new technologies in the areas of power engineering, environmental engineering, chemical engineering, and biotechnology demonstrate the great significance of the problems. It is concluded that corrosion research and corrosion prevention technology will never come to an end but will constantly face new problems. Two technologies are of particular interest since they focus attention on new methods of investigation: microelectronics and final disposal of radioactive wastes. The article closes by considering the importance of the transfer of experience and technology. Since the manufacturs and operators of machines and plant do not generally have access to the very latest knowledge, they should be kept informed through advisory services, experimental studies, databases, and further education. (orig.) [de

  14. Corrosion inhibitors. Manufacture and technology

    International Nuclear Information System (INIS)

    Ranney, M.W.

    1976-01-01

    Detailed information is presented relating to corrosion inhibitors. Areas covered include: cooling water, boilers and water supply plants; oil well and refinery operations; fuel and lubricant additives for automotive use; hydraulic fluids and machine tool lubes; grease compositions; metal surface treatments and coatings; and general processes for corrosion inhibitors

  15. DPC materials and corrosion environments.

    Energy Technology Data Exchange (ETDEWEB)

    Ilgen, Anastasia Gennadyevna; Bryan, Charles R.; Teich-McGoldrick, Stephanie; Hardin, Ernest

    2014-10-01

    After an exposition of the materials used in DPCs and the factors controlling material corrosion in disposal environments, a survey is given of the corrosion rates, mechanisms, and products for commonly used stainless steels. Research needs are then identified for predicting stability of DPC materials in disposal environments. Stainless steel corrosion rates may be low enough to sustain DPC basket structural integrity for performance periods of as long as 10,000 years, especially in reducing conditions. Uncertainties include basket component design, disposal environment conditions, and the in-package chemical environment including any localized effects from radiolysis. Prospective disposal overpack materials exist for most disposal environments, including both corrosion allowance and corrosion resistant materials. Whereas the behavior of corrosion allowance materials is understood for a wide range of corrosion environments, demonstrating corrosion resistance could be more technically challenging and require environment-specific testing. A preliminary screening of the existing inventory of DPCs and other types of canisters is described, according to the type of closure, whether they can be readily transported, and what types of materials are used in basket construction.

  16. Long-term corrosion studies

    International Nuclear Information System (INIS)

    Gdowski, G.

    1998-01-01

    The scope of this activity is to assess the long-term corrosion properties of metallic materials under consideration for fabricating waste package containers. Three classes of metals are to be assessed: corrosion resistant, intermediate corrosion resistant, and corrosion allowance. Corrosion properties to be evaluated are general, pitting and crevice corrosion, stress-corrosion cracking, and galvanic corrosion. The performance of these materials will be investigated under conditions that are considered relevant to the potential emplacement site. Testing in four aqueous solutions, and vapor phases above them, and at two temperatures are planned for this activity. (The environmental conditions, test metals, and matrix are described in detail in Section 3.0.) The purpose and objective of this activity is to obtain the kinetic and mechanistic information on degradation of metallic alloys currently being considered for waste package containers. This information will be used to provide assistance to (1) waste package design (metal barrier selection) (E-20-90 to E-20-92), (2) waste package performance assessment activities (SIP-PA-2), (3) model development (E-20-75 to E-20-89). and (4) repository license application

  17. Fatigue and Corrosion in Metals

    CERN Document Server

    Milella, Pietro Paolo

    2013-01-01

    This textbook, suitable for students, researchers and engineers, gathers the experience of more than 20 years of teaching fracture mechanics, fatigue and corrosion to professional engineers and running experimental tests and verifications to solve practical problems in engineering applications. As such, it is a comprehensive blend of fundamental knowledge and technical tools to address the issues of fatigue and corrosion. The book initiates with a systematic description of fatigue from a phenomenological point of view, since the early signs of submicroscopic damage in few surface grains and continues describing, step by step, how these precursors develop to become mechanically small cracks and, eventually, macrocracks whose growth is governed by fracture mechanics. But fracture mechanics is also introduced to analyze stress corrosion and corrosion assisted fatigue in a rather advanced fashion. The author dedicates a particular attention to corrosion starting with an electrochemical treatment that mechanical e...

  18. IN DRIFT CORROSION PRODUCTS

    Energy Technology Data Exchange (ETDEWEB)

    D.M. Jolley

    1999-12-02

    As directed by a written development plan (CRWMS M&O 1999a), a conceptual model for steel and corrosion products in the engineered barrier system (EBS) is to be developed. The purpose of this conceptual model is to assist Performance Assessment Operations (PAO) and its Engineered Barrier Performance Department in modeling the geochemical environment within a repository drift, thus allowing PAO to provide a more detailed and complete in-drift geochemical model abstraction and to answer the key technical issues (KTI) raised in the NRC Issue Resolution Status Report (IRSR) for the Evolution of the Near-Field Environment (NFE) Revision 2 (NRC 1999). This document provides the conceptual framework for the in-drift corrosion products sub-model to be used in subsequent PAO analyses including the EBS physical and chemical model abstraction effort. This model has been developed to serve as a basis for the in-drift geochemical analyses performed by PAO. However, the concepts discussed within this report may also apply to some near and far-field geochemical processes and may have conceptual application within the unsaturated zone (UZ) and saturated zone (SZ) transport modeling efforts.

  19. Celulitis por citomegalovirus

    Directory of Open Access Journals (Sweden)

    A. Ruiz Lascano

    2002-12-01

    Full Text Available Las lesiones cutáneas por citomegalovirus (CMV son infrecuentes y a menudo una manifestación tardía de una enfermedad sistémica, que generalmente anuncia un curso fatal. Comunicamos un caso de celulitis por CMV: una mujer de 70 años con trasplante renal efectuado 1 mes antes de la consulta, terapia inmunosupresora con ciclosporina A y metilprednisona. La paciente ingresó por fiebre, dolor e impotencia funcional en pierna derecha. Comprobamos la existencia de una placa de 8 por 4 cm eritematoedematosa. La tratamos con antibióticos sin mejoría, por lo que realizamos un estudio histopatológico de piel que mostró cambios citopáticos compatibles con infección por CMV. Los cultivos bacteriológicos y micológicos fueron negativos. La inmunohistoquímica específica para CMV y el estudio de reacción en cadena de la polimerasa (PCR de la biopsia de piel fueron positivas, al igual que la antigenemia. El tratamiento con ganciclovir produjo la mejoría del cuadro clínico. En la literatura revisada no hemos encontrado la celulitis como manifestación de enfermedad cutánea por CMV.

  20. Review of corrosion causes and corrosion control in a technical facility

    International Nuclear Information System (INIS)

    Charng, T.; Lansing, F.

    1982-06-01

    Causes of corrosion of metals and their alloys are reviewed. The corrosion mechanism is explained by electrochemical reaction theory. The causes and methods of controlling of both physiochemical corrosion and biological corrosion are presented. Factors which influence the rate of corrosion are also discussed

  1. Corrosion detection of nanowires by magnetic sensors

    KAUST Repository

    Kosel, Jü rgen; Amara, Selma; Ivanov, Iurii; Blanco, Mario

    2017-01-01

    Disclosed are various embodiments related to a corrosion detection device for detecting corrosive environments. A corrosion detection device comprises a magnetic sensor and at least one magnetic nanowire disposed on the magnetic sensor. The magnetic sensor is configured to detect corrosion of the one or more magnetic nanowires based at least in part on a magnetic field of the one or more magnetic nanowires.

  2. Recognition and Analysis of Corrosion Failure Mechanisms

    Directory of Open Access Journals (Sweden)

    Steven Suess

    2006-02-01

    Full Text Available Corrosion has a vast impact on the global and domestic economy, and currently incurs losses of nearly $300 billion annually to the U.S. economy alone. Because of the huge impact of corrosion, it is imperative to have a systematic approach to recognizing and mitigating corrosion problems as soon as possible after they become apparent. A proper failure analysis includes collection of pertinent background data and service history, followed by visual inspection, photographic documentation, material evaluation, data review and conclusion procurement. In analyzing corrosion failures, one must recognize the wide range of common corrosion mechanisms. The features of any corrosion failure give strong clues as to the most likely cause of the corrosion. This article details a proven approach to properly determining the root cause of a failure, and includes pictographic illustrations of the most common corrosion mechanisms, including general corrosion, pitting, galvanic corrosion, dealloying, crevice corrosion, microbiologically-influenced corrosion (MIC, corrosion fatigue, stress corrosion cracking (SCC, intergranular corrosion, fretting, erosion corrosion and hydrogen damage.

  3. Corrosion detection of nanowires by magnetic sensors

    KAUST Repository

    Kosel, Jürgen

    2017-10-05

    Disclosed are various embodiments related to a corrosion detection device for detecting corrosive environments. A corrosion detection device comprises a magnetic sensor and at least one magnetic nanowire disposed on the magnetic sensor. The magnetic sensor is configured to detect corrosion of the one or more magnetic nanowires based at least in part on a magnetic field of the one or more magnetic nanowires.

  4. A Multifunctional Coating for Autonomous Corrosion Control

    Science.gov (United States)

    Calle, Luz M.; Li, Wenyan; Buhrow, Jerry W.; Jolley, Scott t.

    2011-01-01

    Nearly all metals and their alloys are subject to corrosion that causes them to lose their structural integrity or other critical functionality. Protective coatings are the most commonly used method of corrosion control. However, progressively stricter environmental regulations have resulted in the ban of many commercially available corrosion protective coatings due to the harmful effects of their solvents or corrosion inhibitors. This work concerns the development of a multifunctional smart coating for the autonomous control of corrosion. This coating is being developed to have the inherent ability to detect the chemical changes associated with the onset of corrosion and respond autonomously to indicate it and control it. The multi-functionality of the coating is based on microencapsulation technology specifically designed for corrosion control applications. This design has, in addition to all the advantages of existing microcapsulation designs, the corrosion controlled release function that triggers the delivery of corrosion indicators and inhibitors on demand, only when and where needed. Microencapsulation of self-healing agents for autonomous repair of mechanical damage to the coating is also being pursued. Corrosion indicators, corrosion inhibitors, as well as self-healing agents, have been encapsulated and dispersed into several paint systems to test the corrosion detection, inhibition, and self-healing properties of the coating. Key words: Corrosion, coating, autonomous corrosion control, corrosion indication, corrosion inhibition, self-healing coating, smart coating, multifunctional coating, microencapsulation.

  5. Improvement of PWR reliability by corrosion prevention

    International Nuclear Information System (INIS)

    Takamatsu, Hiroshi

    1999-01-01

    Since first PWR in Japan started commercial operation in 1970, we have encountered the various modes of corrosion on primary and secondary side components. We have paid much efforts for resolving these corrosion problems, that is, investigating the causes of corrosion and establishing the countermeasures for these corrosion. We summarize these efforts in this article. (author)

  6. 49 CFR 172.442 - CORROSIVE label.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false CORROSIVE label. 172.442 Section 172.442... SECURITY PLANS Labeling § 172.442 CORROSIVE label. (a) Except for size and color, the CORROSIVE label must... CORROSIVE label must be white in the top half and black in the lower half. [Amdt. 172-123, 56 FR 66259, Dec...

  7. High temperature corrosion of metals

    International Nuclear Information System (INIS)

    Quadakkers, W.J.; Schuster, H.; Ennis, P.J.

    1988-08-01

    This paper covers three main topics: 1. high temperature oxidation of metals and alloys, 2. corrosion in sulfur containing environments and 3. structural changes caused by corrosion. The following 21 subjects are discussed: Influence of implanted yttrium and lanthanum on the oxidation behaviour of beta-NiA1; influence of reactive elements on the adherence and protective properties of alumina scales; problems related to the application of very fine markers in studying the mechanism of thin scale formation; oxidation behaviour of chromia forming Co-Cr-Al alloys with or without reactive element additions; growth and properties of chromia-scales on high-temperature alloys; quantification of the depletion zone in high temperature alloys after oxidation in process gas; effects of HC1 and of N2 in the oxidation of Fe-20Cr; investigation under nuclear safety aspects of Zircaloy-4 oxidation kinetics at high temperatures in air; on the sulfide corrosion of metallic materials; high temperature sulfide corrosion of Mn, Nb and Nb-Si alloys; corrosion behaviour or NiCrAl-based alloys in air and air-SO2 gas mixtures; sulfidation of cobalt at high temperatures; preoxidation for sulfidation protection; fireside corrosion and application of additives in electric utility boilers; transport properties of scales with complex defect structures; observations of whiskers and pyramids during high temperature corrosion of iron in SO2; corrosion and creep of alloy 800H under simulated coal gasification conditions; microstructural changes of HK 40 cast alloy caused by exploitation in tubes in steam reformer installation; microstructural changes during exposure in corrosive environments and their effect on mechanical properties; coatings against carburization; mathematical modeling of carbon diffusion and carbide precipitation in Ni-Cr-based alloys. (MM)

  8. Corrosion protection and control using nanomaterials

    CERN Document Server

    Cook, R

    2012-01-01

    This book covers the use of nanomaterials to prevent corrosion. The first section deals with the fundamentals of corrosion prevention using nanomaterials. Part two includes a series of case studies and applications of nanomaterials for corrosion control.$bCorrosion is an expensive and potentially dangerous problem in many industries. The potential application of different nanostructured materials in corrosion protection, prevention and control is a subject of increasing interest. Corrosion protection and control using nanomaterials explores the potential use of nanotechnology in corrosion control. The book is divided into two parts. Part one looks at the fundamentals of corrosion behaviour and the manufacture of nanocrystalline materials. Chapters discuss the impact of nanotechnology in reducing corrosion cost, and investigate the influence of various factors including thermodynamics, kinetics and grain size on the corrosion behaviour of nanocrystalline materials. There are also chapters on electrodeposition ...

  9. Cracking and corrosion recovery boiler

    Energy Technology Data Exchange (ETDEWEB)

    Suik, H. [Tallinn Technical University, Horizon Pulp and Paper, Tallinn (Estonia)

    1998-12-31

    The corrosion of heat surfaces and the cracking the drums are the main problems of the recovery boiler. These phenomena have been appeared during long-term operation of boiler `Mitsubishi - 315` erected at 1964. Depth of the crack is depending on the number of shutdowns and on operation time. Corrosion intensity of different heat surfaces is varying depend on the metal temperature and the conditions at place of positioning of tube. The lowest intensity of corrosion is on the bank tubes and the greatest is on the tubes of the second stage superheater and on the tubes at the openings of air ports. (orig.) 5 refs.

  10. Corrosion-resistant coating development

    Energy Technology Data Exchange (ETDEWEB)

    Stinton, D.P.; Kupp, D.M.; Martin, R.L. [Oak Ridge National Lab., TN (United States)

    1997-12-01

    SiC-based heat exchangers have been identified as the prime candidate material for use as heat exchangers in advanced combined cycle power plants. Unfortunately, hot corrosion of the SiC-based materials created by alkali metal salts present in the combustion gases dictates the need for corrosion-resistant coatings. The well-documented corrosion resistance of CS-50 combined with its low (and tailorable) coefficient of thermal expansion and low modulus makes CS-50 an ideal candidate for this application. Coatings produced by gelcasting and traditional particulate processing have been evaluated.

  11. Cracking and corrosion recovery boiler

    Energy Technology Data Exchange (ETDEWEB)

    Suik, H [Tallinn Technical University, Horizon Pulp and Paper, Tallinn (Estonia)

    1999-12-31

    The corrosion of heat surfaces and the cracking the drums are the main problems of the recovery boiler. These phenomena have been appeared during long-term operation of boiler `Mitsubishi - 315` erected at 1964. Depth of the crack is depending on the number of shutdowns and on operation time. Corrosion intensity of different heat surfaces is varying depend on the metal temperature and the conditions at place of positioning of tube. The lowest intensity of corrosion is on the bank tubes and the greatest is on the tubes of the second stage superheater and on the tubes at the openings of air ports. (orig.) 5 refs.

  12. Assessing resistance of stabilized corrosion resistant steels to intergranular corrosion

    International Nuclear Information System (INIS)

    Karas, A.; Cihal, V. Jr.; Vanek, V.; Herzan, J.; Protiva, K.; Cihal, V.

    1987-01-01

    Resistance to intergranular corrosion was determined for four types of titanium-stabilized steels from the coefficients of stabilization efficiency according to the degree the chemical composition was known. The ATA SUPER steel showed the highest resistance parameter value. The resistance of this type of steel of a specific composition, showing a relatively low value of mean nitrogen content was compared with steel of an optimized chemical composition and with low-carbon niobium stabilized, molybdenum modified steels. The comparison showed guarantees of a sufficient resistance of the steel to intergranular corrosion. The method of assessing the resistance to intergranular corrosion using the calculation of the minimum content of Cr', i.e., the effective chromium content, and the maximum effective carbon content C' giving the resistance parameter k seems to be prospective for practical use in the production of corrosion resistant steels. (author). 1 tab., 5 figs., 15 refs

  13. Corrosion and corrosion fatigue of airframe aluminum alloys

    Science.gov (United States)

    Chen, G. S.; Gao, M.; Harlow, D. G.; Wei, R. P.

    1994-01-01

    Localized corrosion and corrosion fatigue crack nucleation and growth are recognized as degradation mechanisms that effect the durability and integrity of commercial transport aircraft. Mechanically based understanding is needed to aid the development of effective methodologies for assessing durability and integrity of airframe components. As a part of the methodology development, experiments on pitting corrosion, and on corrosion fatigue crack nucleation and early growth from these pits were conducted. Pitting was found to be associated with constituent particles in the alloys and pit growth often involved coalescence of individual particle-nucleated pits, both laterally and in depth. Fatigue cracks typically nucleated from one of the larger pits that formed by a cluster of particles. The size of pit at which fatigue crack nucleates is a function of stress level and fatigue loading frequency. The experimental results are summarized, and their implications on service performance and life prediction are discussed.

  14. pitting corrosion susceptibility pitting corrosion susceptibility of aisi

    African Journals Online (AJOL)

    eobe

    2DEPARTMENT OF MECHANICAL ENGINEERING, UNIVERSITY OF BENIN, BENIN- CITY, EDO STATE, NIGERIA. E-mail addresses: ... fluids and aggressive chemicals. Pitting corrosion ... the kitchen, food manufacturing and dispensing and.

  15. Corrosion resistant ceramic materials

    Science.gov (United States)

    Kaun, T.D.

    1996-07-23

    Ceramic materials are disclosed which exhibit stability in severely-corrosive environments having high alkali-metal activity, high sulfur/sulfide activity and/or molten halides at temperatures of 200--550 C or organic salt (including SO{sub 2} and SO{sub 2}Cl{sub 2}) at temperatures of 25--200 C. These sulfide ceramics form stoichiometric (single-phase) compounds with sulfides of Ca, Li, Na, K, Al, Mg, Si, Y, La, Ce, Ga, Ba, Zr and Sr and show melting-points that are sufficiently low and have excellent wettability with many metals (Fe, Ni, Mo) to easily form metal/ceramic seals. Ceramic compositions are also formulated to adequately match thermal expansion coefficient of adjacent metal components. 1 fig.

  16. Mortar fights acid corrosion

    Energy Technology Data Exchange (ETDEWEB)

    1982-05-14

    The burning of coal or oil to produce heat required to operate a power boiler also generates a severe corrosion problem within the interior of the duct and stacks used to emit the flue gas into the atmosphere. How can concrete and steel be protected from the effects of acid attack, when the acids are carried in a gas form, or come into direct contact with the steel or concrete from spillage or immersion conditions. Industry in North America has found that the solution to this problem is to build an outside concrete column, in this case of Portland cement, and inside that column, build a totally independent brick liner bonded with Sauereisen mortar.

  17. Erosion--corrosion

    International Nuclear Information System (INIS)

    Vyas, B.

    1978-01-01

    The deterioration of materials by corrosion or erosion by itself presents a formidable problem and for this reason investigators have studied these two phenomena independently. In fact, there are very few systematic studies on E-C and the majority of references mention it only in passing. In most real systems, however, the two destructive processes take place simultaneously, hence the purpose of this review is to present the various interactions between the chemical and mechanical agents leading to accelerated degradation of the material. The papers cited in the review are those that lead to a better understanding of the process involved in the accelerated rate of material loss under E-C conditions

  18. Corrosion resistant ceramic materials

    Science.gov (United States)

    Kaun, Thomas D.

    1996-01-01

    Ceramic materials which exhibit stability in severely-corrosive environments having high alkali-metal activity, high sulfur/sulfide activity and/or molten halides at temperatures of 200.degree.-550.degree. C. or organic salt (including SO.sub.2 and SO.sub.2 Cl.sub.2) at temperatures of 25.degree.-200.degree. C. These sulfide ceramics form stoichiometric (single-phase) compounds with sulfides of Ca, Li, Na, K, Al, Mg, Si, Y, La, Ce, Ga, Ba, Zr and Sr and show melting-points that are sufficiently low and have excellent wettability with many metals (Fe, Ni, Mo) to easily form metal/ceramic seals. Ceramic compositions are also formulated to adequately match thermal expansion coefficient of adjacent metal components.

  19. Critical Study of Corrosion Damaged Concrete Structures

    OpenAIRE

    Sallehuddin Shah Ayop; John Cairns

    2013-01-01

    Corrosion of steel reinforcement in concrete is one of the major problems with respect to the durability of reinforced concrete structures. The degradation of the structure strength due to reinforcement corrosion decreases its design life. This paper presents the literature study on the influence of the corrosion on concrete structure starting from the mechanism of the corrosion until the deterioration stage and the structural effects of corrosion on concrete structures.

  20. Corrosion testing and prediction in SCWO environments

    International Nuclear Information System (INIS)

    Kriksunov, L.B.; Macdonald, D.D.

    1995-01-01

    The authors review recent advances in corrosion monitoring and modeling in SCWO systems. Techniques and results of experimental corrosion measurements at high temperatures are presented. Results of modeling corrosion in high subcritical and supercritical aqueous systems indicate the primary importance of density of water in corrosion processes. A phenomenological model has been developed to simulate corrosion processes at nearcritical and supercritical temperatures in SCWO systems. They discuss as well the construction of Pourbaix diagrams for metals in SCW

  1. Review on stress corrosion and corrosion fatigue failure of centrifugal compressor impeller

    Science.gov (United States)

    Sun, Jiao; Chen, Songying; Qu, Yanpeng; Li, Jianfeng

    2015-03-01

    Corrosion failure, especially stress corrosion cracking and corrosion fatigue, is the main cause of centrifugal compressor impeller failure. And it is concealed and destructive. This paper summarizes the main theories of stress corrosion cracking and corrosion fatigue and its latest developments, and it also points out that existing stress corrosion cracking theories can be reduced to the anodic dissolution (AD), the hydrogen-induced cracking (HIC), and the combined AD and HIC mechanisms. The corrosion behavior and the mechanism of corrosion fatigue in the crack propagation stage are similar to stress corrosion cracking. The effects of stress ratio, loading frequency, and corrosive medium on the corrosion fatigue crack propagation rate are analyzed and summarized. The corrosion behavior and the mechanism of stress corrosion cracking and corrosion fatigue in corrosive environments, which contain sulfide, chlorides, and carbonate, are analyzed. The working environments of the centrifugal compressor impeller show the behavior and the mechanism of stress corrosion cracking and corrosion fatigue in different corrosive environments. The current research methods for centrifugal compressor impeller corrosion failure are analyzed. Physical analysis, numerical simulation, and the fluid-structure interaction method play an increasingly important role in the research on impeller deformation and stress distribution caused by the joint action of aerodynamic load and centrifugal load.

  2. Metallurgy of stress corrosion cracking

    International Nuclear Information System (INIS)

    Donovan, J.A.

    1973-01-01

    The susceptibility of metals and alloys to stress corrosion is discussed in terms of the relationship between structural characteristics (crystal structure, grains, and second phases) and defects (vacancies, dislocations, and cracks) that exist in metals and alloys. (U.S.)

  3. Heated Aluminum Tanks Resist Corrosion

    Science.gov (United States)

    Johnson, L. E.

    1983-01-01

    Simple expedient of heating foam-insulated aluminum alloy tanks prevents corrosion by salt-laden moisture. Relatively-small temperature difference between such tank and surrounding air will ensure life of tank is extended by many years.

  4. Corrosion resistant neutron absorbing coatings

    Science.gov (United States)

    Choi, Jor-Shan [El Cerrito, CA; Farmer, Joseph C [Tracy, CA; Lee, Chuck K [Hayward, CA; Walker, Jeffrey [Gaithersburg, MD; Russell, Paige [Las Vegas, NV; Kirkwood, Jon [Saint Leonard, MD; Yang, Nancy [Lafayette, CA; Champagne, Victor [Oxford, PA

    2012-05-29

    A method of forming a corrosion resistant neutron absorbing coating comprising the steps of spray or deposition or sputtering or welding processing to form a composite material made of a spray or deposition or sputtering or welding material, and a neutron absorbing material. Also a corrosion resistant neutron absorbing coating comprising a composite material made of a spray or deposition or sputtering or welding material, and a neutron absorbing material.

  5. Dictionary corrosion and corrosion control. English-German/German-English. Fachwoerterbuch Korrosion und Korrosionsschutz. Englisch-Deutsch/Deutsch-Englisch

    Energy Technology Data Exchange (ETDEWEB)

    1985-01-01

    This dictionary has 13000 entries in both languages. Keywords and extensive accompanying information simplify the choice of word for the user. The following topics are covered: Theoretical principles of corrosion; Corrosion of the metals and alloys most frequently used in engineering. Types of corrosion - (chemical-, electro-chemical, biological corrosion); forms of corrosion (superficial, pitting, selective, intercrystalline and stress corrosion; vibrational corrosion cracking); erosion and cavitation. Methods of corrosion control (material selection, temporary corrosion protection media, paint and plastics coatings, electro-chemical coatings, corrosion prevention by treatment of the corrosive media); Corrosion testing methods.

  6. A review on pipeline corrosion, in-line inspection (ILI), and corrosion growth rate models

    International Nuclear Information System (INIS)

    Vanaei, H.R.; Eslami, A.; Egbewande, A.

    2017-01-01

    Pipelines are the very important energy transmission systems. Over time, pipelines can corrode. While corrosion could be detected by in-line inspection (ILI) tools, corrosion growth rate prediction in pipelines is usually done through corrosion rate models. For pipeline integrity management and planning selecting the proper corrosion ILI tool and also corrosion growth rate model is important and can lead to significant savings and safer pipe operation. In this paper common forms of pipeline corrosion, state of the art ILI tools, and also corrosion growth rate models are reviewed. The common forms of pipeline corrosion introduced in this paper are Uniform/General Corrosion, Pitting Corrosion, Cavitation and Erosion Corrosion, Stray Current Corrosion, Micro-Bacterial Influenced Corrosion (MIC). The ILI corrosion detection tools assessed in this study are Magnetic Flux Leakage (MFL), Circumferential MFL, Tri-axial MFL, and Ultrasonic Wall Measurement (UT). The corrosion growth rate models considered in this study are single-value corrosion rate model, linear corrosion growth rate model, non-linear corrosion growth rate model, Monte-Carlo method, Markov model, TD-GEVD, TI-GEVD model, Gamma Process, and BMWD model. Strengths and limitations of ILI detection tools, and also corrosion predictive models with some practical examples are discussed. This paper could be useful for those whom are supporting pipeline integrity management and planning. - Highlights: • Different forms of pipeline corrosion are explained. • Common In-Line Inspection (ILI) tools and corrosion growth rate models are introduced. • Strength and limitations of corrosion growth rate models/ILI tools are discussed. • For pipeline integrity management programs using more than one corrosion growth rate model/ILI tool is suggested.

  7. Producción de IFN−γ en cultivos de linfocitos humanos por efecto de los extractos metanólicos de cuatro ecotipos de Lepidium peruvianum, Chacón (Brassicaceae

    Directory of Open Access Journals (Sweden)

    Libertad Alzamora

    2013-05-01

    Full Text Available Se estudió la actividad inmunoduladora sobre cultivos de linfocitos T humanos de sangre periférica. Se evaluó la producción de IFN−γ inducida por los extractos metanólicos (EM de los ecotipos blanco, negro, rojo y morado de Lepidium peruvianum (conocida también como Lepidium meyenii Walp. maca. Luego de cultivar los linfocitos con los respectivos EM de maca durante 14 horas sólo el EM del ecotipo morado indujo la producción significativa de IFN−γ cuantificada mediante Elispot. El extracto metanólico del ecotipo morado de maca posee propiedades inmunoestimuladoras importantes, desencadenando la activación de linfocitos T humanos.

  8. Electrocardiografo por computadora

    OpenAIRE

    Tinoco Hernandez, Rosanna; Paredes Bejarano, Margarita; Romero Chaglia, Norman; Yapur Auad, Miguel Eduardo

    2009-01-01

    El presente trabajo trata sobrees el diseño y la implementación de un graficador de señales cardiacas por computadora, para lo cual diseñamos un circuito electrónico capaz de recibir la senal analógica proveniente de la actividad electrica del corazón , amplificarla, y luego convertirla en una señal digital para ser procesada por software y finalmente ser graficada, siendo posible así observar la señal cardiaca en el monitor de un computador como un tren de pulsos. Cabe destacar que par...

  9. Corrosion behavior of corrosion resistant alloys in stimulation acids

    Energy Technology Data Exchange (ETDEWEB)

    Cheldi, Tiziana [ENI E and P Division, 20097 San Donato Milanese Milano (Italy); Piccolo, Eugenio Lo; Scoppio, Lucrezia [Centro Sviluppo Materiali, via Castel Romano 100, 00128 Rome (Italy)

    2004-07-01

    In the oil and gas industry, selection of CRAs for downhole tubulars is generally based on resistance to corrosive species in the production environment containing CO{sub 2}, H{sub 2}S, chloride and in some case elemental sulphur. However, there are non-production environments to which these materials must also be resistant for either short term or prolonged duration; these environments include stimulation acids, brine and completion fluids. This paper reports the main results of a laboratory study performed to evaluate the corrosion and stress corrosion behaviour to the acidizing treatments of the most used CRAs for production tubing and casing. Laboratory tests were performed to simulate both 'active' and 'spent' acids operative phases, selecting various environmental conditions. The selected steel pipes were a low alloyed steel, martensitic, super-martensitic, duplex 22 Cr, superduplex 25 Cr and super-austenitic stainless steels (25 Cr 35 Ni). Results obtained in the 'active' acid environments over the temperature range of 100-140 deg. C, showed that the blend acids with HCl at high concentration and HCl + HF represented too much severe conditions, where preventing high general corrosion and heavy localised corrosion by inhibition package becomes very difficult, especially for duplex steel pipe, where, in some case, the specimens were completely dissolved into the solution. On the contrary, all steels pipes were successfully protected by inhibitor when organic acid solution (HCOOH + CH{sub 3}COOH) were used. Furthermore, different effectiveness on corrosion protection was showed by the tested inhibitors packages: e.g. in the 90% HCl at 12% + 10 CH{sub 3}COOH acid blend. In 'spent' acid environments, all steel pipes showed to be less susceptible to the localised and general corrosion attack. Moreover, no Sulphide Stress Corrosion Cracking (SSC) was observed. Only one super-austenitic stainless steel U-bend specimen showed

  10. Corrosion control in nuclear fuel reprocessing

    International Nuclear Information System (INIS)

    Steele, D.F.

    1986-01-01

    This article looks in detail at tribology-related hazards of corrosion in irradiated fuel reprocessing plants and tries to identify and minimize problems which could contribute to disaster. First, the corrosion process is explained. Then the corrosion aspects at each of four stages in reprocessing are examined, with particular reference to oxide fuel reprocessing. The four stages are fuel receipt and storage, fuel breakdown and dissolution, solvent extraction and product concentration and waste management. Results from laboratory and plant corrosion trails are used at the plant design stage to prevent corrosion problems arising. Operational procedures which minimize corrosion if it cannot be prevented at the design stage, are used. (UK)

  11. A Theoretical Model for Metal Corrosion Degradation

    Directory of Open Access Journals (Sweden)

    David V. Svintradze

    2010-01-01

    Full Text Available Many aluminum and stainless steel alloys contain thin oxide layers on the metal surface which greatly reduce the corrosion rate. Pitting corrosion, a result of localized breakdown of such films, results in accelerated dissolution of the underlying metal through pits. Many researchers have studied pitting corrosion for several decades and the exact governing equation for corrosion pit degradation has not been obtained. In this study, the governing equation for corrosion degradation due to pitting corrosion behavior was derived from solid-state physics and some solutions and simulations are presented and discussed.

  12. General Corrosion and Localized Corrosion of the Drip Shield

    Energy Technology Data Exchange (ETDEWEB)

    F. Hua

    2004-09-16

    The repository design includes a drip shield (BSC 2004 [DIRS 168489]) that provides protection for the waste package both as a barrier to seepage water contact and a physical barrier to potential rockfall. The purpose of the process-level models developed in this report is to model dry oxidation, general corrosion, and localized corrosion of the drip shield plate material, which is made of Ti Grade 7. This document is prepared according to ''Technical Work Plan For: Regulatory Integration Modeling and Analysis of the Waste Form and Waste Package'' (BSC 2004 [DIRS 171583]). The models developed in this report are used by the waste package degradation analyses for TSPA-LA and serve as a basis to determine the performance of the drip shield. The drip shield may suffer from other forms of failure such as the hydrogen induced cracking (HIC) or stress corrosion cracking (SCC), or both. Stress corrosion cracking of the drip shield material is discussed in ''Stress Corrosion Cracking of the Drip Shield, the Waste Package Outer Barrier, and the Stainless Steel Structural Material'' (BSC 2004 [DIRS 169985]). Hydrogen induced cracking of the drip shield material is discussed in ''Hydrogen Induced Cracking of Drip Shield'' (BSC 2004 [DIRS 169847]).

  13. General Corrosion and Localized Corrosion of the Drip Shield

    International Nuclear Information System (INIS)

    F. Hua

    2004-01-01

    The repository design includes a drip shield (BSC 2004 [DIRS 168489]) that provides protection for the waste package both as a barrier to seepage water contact and a physical barrier to potential rockfall. The purpose of the process-level models developed in this report is to model dry oxidation, general corrosion, and localized corrosion of the drip shield plate material, which is made of Ti Grade 7. This document is prepared according to ''Technical Work Plan For: Regulatory Integration Modeling and Analysis of the Waste Form and Waste Package'' (BSC 2004 [DIRS 171583]). The models developed in this report are used by the waste package degradation analyses for TSPA-LA and serve as a basis to determine the performance of the drip shield. The drip shield may suffer from other forms of failure such as the hydrogen induced cracking (HIC) or stress corrosion cracking (SCC), or both. Stress corrosion cracking of the drip shield material is discussed in ''Stress Corrosion Cracking of the Drip Shield, the Waste Package Outer Barrier, and the Stainless Steel Structural Material'' (BSC 2004 [DIRS 169985]). Hydrogen induced cracking of the drip shield material is discussed in ''Hydrogen Induced Cracking of Drip Shield'' (BSC 2004 [DIRS 169847])

  14. Concrete cover cracking with reinforcement corrosion of RC beam during chloride-induced corrosion process

    International Nuclear Information System (INIS)

    Zhang Ruijin; Castel, Arnaud; Francois, Raoul

    2010-01-01

    This paper deals with the evolution of the corrosion pattern based on two beams corroded by 14 years (beam B1CL1) and 23 years (beam B2CL1) of conservation in a chloride environment. The experimental results indicate that, at the cracking initiation stage and the first stage of cracking propagation, localized corrosion due to chloride ingress is the predominant corrosion pattern and pitting corrosion is the main factor that influences the cracking process. As corrosion cracking increases, general corrosion develops rapidly and gradually becomes predominant in the second stage of cracking propagation. A comparison between existing models and experimental results illustrates that, although Vidal et al.'s model can better predict the reinforcement corrosion of beam B1CL1 under localized corrosion, it cannot predict the corrosion of beam B2CL1 under general corrosion. Also, Rodriguez's model, derived from the general corrosion due to electrically accelerated corrosion experiments, cannot match natural chloride corrosion irrespective of whether corrosion is localized or general. Thus, for natural general corrosion in the second stage of cracking propagation, a new model based on the parameter of average steel cross-section loss is put forward to predict steel corrosion from corrosion cracking.

  15. PLANTS AS A SOURCE OF GREEN CORROSION INHIBITORS ...

    African Journals Online (AJOL)

    Mgina

    Acacia senegal) exhibit good inhibition characteristics to corrosion on mild steel under fresh water medium and the ... as corrosion inhibitors for metals in various corrosive media ..... alloy corrosion in chloride solution", J. Appl. Electrochem.

  16. Indice por Materias

    Directory of Open Access Journals (Sweden)

    Montoya H Luz Marina

    1982-09-01

    Full Text Available Un índice es una lista de palabras o frases indicadores asociados que permite la ubicación de material al interior de un libro o una publicación, en este caso será por el nombre de la materia.

  17. Neurotoxicity and aggressiveness triggered by low-level lead in children: a review Neurotoxicidad y agresividad desencadenadas por bajos niveles de plomo en niños: una revisión

    Directory of Open Access Journals (Sweden)

    Kelly Polido Kaneshiro Olympio

    2009-09-01

    Full Text Available Lead-induced neurotoxicity acquired by low-level long-term exposure has special relevance for children. A plethora of recent reports has demonstrated a direct link between low-level lead exposure and deficits in the neurobehavioral-cognitive performance manifested from childhood through adolescence. In many studies, aggressiveness and delinquency have also been suggested as symptoms of lead poisoning. Several environmental, occupational and domestic sources of contaminant lead and consequent health risks are largely identified and understood, but the occurrences of lead poisoning remain numerous. There is an urgent need for public health policies to prevent lead poisoning so as to reduce individual and societal damages and losses. In this paper we describe unsuspected sources of contaminant lead, discuss the economic losses and urban violence possibly associated with lead contamination and review the molecular basis of lead-induced neurotoxicity, emphasizing its effects on the social behavior, delinquency and IQ of children and adolescents.La neurotoxicidad adquirida inducida por la exposición prolongada a bajos niveles de plomo tiene una importancia especial en los niños. Una plétora de publicaciones recientes ha demostrado el vínculo directo existente entre la exposición a bajos niveles de plomo y el déficit en el desempeño neuroconductual-cognitivo manifestado desde la infancia hasta el final de la adolescencia. En numerosos estudios, la agresividad y la delincuencia juvenil también se han considerado síntomas de la intoxicación por plomo. Se han identificado y explicado ampliamente varias fuentes ambientales, laborales y domésticas de contaminación por plomo y los riesgos resultantes para la salud, pero aún son numerosos los casos de intoxicación por plomo. Se necesitan urgentes políticas de salud pública para prevenir la intoxicación por plomo de manera de reducir los daños y las pérdidas, tanto individuales como para la

  18. Inducción de la enzima triptófano 2,3 dioxigenasa por glucocorticoides y su papel en la tolerancia materna al feto

    Directory of Open Access Journals (Sweden)

    Angela Cadavid

    2004-02-01

    Full Text Available

    El mecanismo por el cual la madre no rechaza al feto, sigue siendo una incógnita en la inmunología de la reproducción. Una de las hipótesis planteadas es la inmunosupresión mediada por el catabolismo del triptófano, el cual es un amino ácido sencial para la proliferación de los linfocitos T. Una de las nzimas que cataboliza el triptófano es la triptófano 2,3 ioxigenasa (TDO.
    La TDO es inducida por los glucocorticoides en el hígado, pero aún no se conoce si estos inducen la producción de la TDO n la interfase materno fetal al interactuar con los receptores resentes en células estromales y NK; En un modelo murino, e observó que la TDO se expresa en la interfase materno etal con un pico que coincide con el de mayor actividad de egradación del triptófano, sugiriendo entonces que esta nzima puede estar involucrada en la tolerancia materna al feto.

     

     

  19. Graphene: corrosion-inhibiting coating.

    Science.gov (United States)

    Prasai, Dhiraj; Tuberquia, Juan Carlos; Harl, Robert R; Jennings, G Kane; Rogers, Bridget R; Bolotin, Kirill I

    2012-02-28

    We report the use of atomically thin layers of graphene as a protective coating that inhibits corrosion of underlying metals. Here, we employ electrochemical methods to study the corrosion inhibition of copper and nickel by either growing graphene on these metals, or by mechanically transferring multilayer graphene onto them. Cyclic voltammetry measurements reveal that the graphene coating effectively suppresses metal oxidation and oxygen reduction. Electrochemical impedance spectroscopy measurements suggest that while graphene itself is not damaged, the metal under it is corroded at cracks in the graphene film. Finally, we use Tafel analysis to quantify the corrosion rates of samples with and without graphene coatings. These results indicate that copper films coated with graphene grown via chemical vapor deposition are corroded 7 times slower in an aerated Na(2)SO(4) solution as compared to the corrosion rate of bare copper. Tafel analysis reveals that nickel with a multilayer graphene film grown on it corrodes 20 times slower while nickel surfaces coated with four layers of mechanically transferred graphene corrode 4 times slower than bare nickel. These findings establish graphene as the thinnest known corrosion-protecting coating.

  20. A new corrosion monitoring technique

    International Nuclear Information System (INIS)

    Brown, Gerald K.

    2000-01-01

    Internal Corrosion Monitoring has relied upon 5 basic techniques. Little improvement in performance has been achieved in any of these. Many newer internal corrosion monitoring techniques have proved of little value in the field although some have instances of success in the laboratory. Industry has many high value hydrocarbon applications requiring corrosion rate monitoring for real-time problem solving and control. The high value of assets and the cost of asset replacement makes it necessary to practice cost effective process and corrosion control with sensitivity beyond the 5 basic techniques. This new metal loss technology offers this sensitivity. Traditional metal loss technology today provides either high sensitivity with short life, or conversely, long life but with substantially reduced sensitivity. The new metal loss technology offers an improved working life of sensors without significantly compromising performance. The paper discusses the limitations of existing on-line technologies and describes the performance of a new technology. This new metal loss technology was introduced at NACE Corrosion 99'. Since that time several field projects have been completed or are ongoing. This paper will discuss the new metal loss technology and report on some of the data that has been obtained.(author)

  1. Corrosion effects on friction factors

    International Nuclear Information System (INIS)

    Magleby, H.L.; Shaffer, S.J.

    1996-01-01

    This paper presents the results of NRC-sponsored material specimen tests that were performed to determine if corrosion increases the friction factors of sliding surfaces of motor-operated gate valves, which could require higher forces to close and open safety-related valves when subjected to their design basis differential pressures. Friction tests were performed with uncorroded specimens and specimens subjected to accelerated corrosion. Preliminary tests at ambient conditions showed that corrosion increased the friction factors, indicating the need for additional tests duplicating valve operating parameters at hot conditions. The additional tests showed friction factors of corroded specimens were 0.1 to 0.2 higher than for uncorroded specimens, and that the friction factors of the corroded specimens were not very dependent on contact stress or corrosion film thickness. The measured values of friction factors for the three corrosion films tested (simulating three operating times) were in the range of 0.3 to 0.4. The friction factor for even the shortest simulated operating time was essentially the same as the others, indicating that the friction factors appear to reach a plateau and that the plateau is reached quickly

  2. Hanford transuranic storage corrosion review

    International Nuclear Information System (INIS)

    Nelson, J.L.; Divine, J.R.

    1980-12-01

    The rate of atmospheric corrosion of the transuranic (TRU) waste drums at the US Department of Energy's Hanford Project, near Richland, Washington, was evaluated by Pacific Northwest Laboratory (PNL). The rate of corrosion is principally contingent upon the effects of humidity, airborne pollutants, and temperature. Results of the study indicate that actual penetration of barrels due to atmospheric corrosion will probably not occur within the 20-year specified recovery period. Several other US burial sites were surveyed, and it appears that there is sufficient uncertainty in the available data to prevent a clearcut statement of the corrosion rate at a specific site. Laboratory and site tests are recommended before any definite conclusions can be made. The corrosion potential at the Hanford TRU waste site could be reduced by a combination of changes in drum materials (for example, using galvanized barrels instead of the currently used mild steel barrels), environmental exposure conditions (for example, covering the barrels in one of numerous possible ways), and storage conditions

  3. Synergy effect of naphthenic acid corrosion and sulfur corrosion in crude oil distillation unit

    Science.gov (United States)

    Huang, B. S.; Yin, W. F.; Sang, D. H.; Jiang, Z. Y.

    2012-10-01

    The synergy effect of naphthenic acid corrosion and sulfur corrosion at high temperature in crude oil distillation unit was studied using Q235 carbon-manganese steel and 316 stainless steel. The corrosion of Q235 and 316 in corrosion media containing sulfur and/or naphthenic acid at 280 °C was investigated by weight loss, scanning electron microscope (SEM), EDS and X-ray diffractometer (XRD) analysis. The results showed that in corrosion media containing only sulfur, the corrosion rate of Q235 and 316 first increased and then decreased with the increase of sulfur content. In corrosion media containing naphthenic acid and sulfur, with the variations of acid value or sulfur content, the synergy effect of naphthenic acid corrosion and sulfur corrosion has a great influence on the corrosion rate of Q235 and 316. It was indicated that the sulfur accelerated naphthenic acid corrosion below a certain sulfur content but prevented naphthenic acid corrosion above that. The corrosion products on two steels after exposure to corrosion media were investigated. The stable Cr5S8 phases detected in the corrosion products film of 316 were considered as the reason why 316 has greater corrosion resistance to that of Q235.

  4. Quantitative measures of corrosion and prevention: application to corrosion in agriculture

    NARCIS (Netherlands)

    Schouten, J.C.; Gellings, P.J.

    1987-01-01

    The corrosion protection factor (c.p.f.) and the corrosion condition (c.c.) are simple instruments for the study and evaluation of the contribution and efficiency of several methods of corrosion prevention and control. The application of c.p.f. and c.c. to corrosion and prevention in agriculture in

  5. Some observations about the Incoloy 800 corrosion

    International Nuclear Information System (INIS)

    Baptista, W.; Sathler, L.; Mattos, O.R.

    1985-01-01

    The chemical and electrochemical characteristics of synthetic solutions similar to those inside the occluded cell corrosion - OCC (pitting, cracks from stress corrosion) of incoloy 800, 25 0 C are studied. (E.G.) [pt

  6. Rail base corrosion and cracking prevention

    Science.gov (United States)

    2014-07-01

    Rail base corrosion combined with fatigue or damage can significantly reduce rail life. Studies were done to examine the relative contribution of damage, corrosion, and fatigue on rail life. The combined effects can be separated into constituent fact...

  7. Corrosion studies on PREPP waste form

    International Nuclear Information System (INIS)

    Welch, J.M.; Neilson, R.M. Jr.

    1984-05-01

    Deformation or Failure Test and Accelerated Corrosion Test procedures were conducted to investigate the effect of formulation variables on the corrosion of oversize waste in Process Experimental Pilot Plant (PREPP) concrete waste forms. The Deformation or Failure Test did not indicate substantial waste form swelling from corrosion. The presence or absence of corrosion inhibitor was the most significant factor relative to measured half-cell potentials identified in the Accelerated Corrosion Test. However, corrosion inhibitor was determined to be only marginally beneficial. While this study produced no evidence that corrosion is of sufficient magnitude to produce serious degradation of PREPP waste forms, the need for corrosion rate testing is suggested. 11 references, 4 figures, 8 tables

  8. Corrosion problems in light water nuclear reactors

    International Nuclear Information System (INIS)

    Berry, W.E.

    1984-01-01

    The corrosion problems encountered during the author's career are reviewed. Attention is given to the development of Zircaloys and attendant factors that affect corrosion; the caustic and chloride stress corrosion cracking (SCC) of austenitic stainless steel steam generator tubing; the qualification of Inconel Alloy 600 for steam generator tubing and the subsequent corrosion problem of secondary side wastage, caustic SCC, pitting, intergranular attack, denting, and primary side SCC; and SCC in weld and furnace sensitized stainless steel piping and internals in boiling water reactor primary coolants. Also mentioned are corrosion of metallic uranium alloy fuels; corrosion of aluminum and niobium candidate fuel element claddings; crevice corrosion and seizing of stainless steel journal-sleeve combinations; SCC of precipitation hardened and martensitic stainless steels; low temperature SCC of welded austenitic stainless steels by chloride, fluoride, and sulfur oxy-anions; and corrosion problems experienced by condensers

  9. Accelerated Test Method for Corrosion Protective Coatings

    Data.gov (United States)

    National Aeronautics and Space Administration — This project seeks to develop a new accelerated corrosion test method that predicts the long-term corrosion protection performance of spaceport structure coatings as...

  10. Microencapsulation of Corrosion Indicators for Smart Coatings

    Science.gov (United States)

    Li, Wenyan; Buhrow, Jerry W.; Jolley, Scott T.; Calle, Luz M.; Hanna,Joshua S.; Rawlins, James W.

    2011-01-01

    A multifunctional smart coating for the autonomous detection, indication, and control of corrosion is been developed based on microencapsulation technology. This paper summarizes the development, optimization, and testing of microcapsules specifically designed for early detection and indication of corrosion when incorporated into a smart coating. Results from experiments designed to test the ability of the microcapsules to detect and indicate corrosion, when blended into several paint systems, show that these experimental coatings generate a color change, indicative of spot specific corrosion events, that can be observed with the naked eye within hours rather than the hundreds of hours or months typical of the standard accelerated corrosion test protocols.. Key words: smart coating, corrosion detection, microencapsulation, microcapsule, pH-sensitive microcapsule, corrosion indicator, corrosion sensing paint

  11. Corrosion monitoring using FSM technology

    International Nuclear Information System (INIS)

    Strommen, R.; Horn, H.; Gartland, P.O.; Wold, K.; Haroun, M.

    1995-01-01

    FSM is a non-intrusive monitoring technique based on a patented principle, developed for the purpose of detection and monitoring of both general and localized corrosion, erosion, and cracking in steel and metal structures, piping systems, and vessels. Since 1991, FSM has been used for a wide range of applications, including for buried and open pipelines, process piping offshore, subsea pipelines and flowlines, applications in the nuclear power industry, and in materials, research in general. This paper describes typical applications of the FSM technology, and presents operational experience from some of the land-based and subsea installations. The paper also describes recent enhancements in the FSM technology and in the analysis of FSM readings, allowing for monitoring and detailed quantification of pitting and mesa corrosion, and of corrosion in welds

  12. Corrosion of Al-7075 by uranium hexafluoride

    International Nuclear Information System (INIS)

    1989-01-01

    The results of the Al-7075 corrosion by uranium hexafluoride are presented in this work. The kinetic study shows that corrosion process occurs by two temperature dependent mechanism and that the alloy can be safely used up to 140 0 C. The corrosion film is formed by uranium oxifluoride with variable composition in depth. Two alternative corrosion models are proposed in order to explain the experimental results, as well as the tests taht will be carried out to confirm one of them [pt

  13. Erosion–corrosion and corrosion properties of DLC coated low temperature Erosion–corrosion and corrosion properties of DLC coated low temperature

    DEFF Research Database (Denmark)

    Jellesen, Morten Stendahl; Christiansen, Thomas; Hilbert, Lisbeth Rischel

    2009-01-01

    of AISI 316 as substrate for DLC coatings are investigated. Corrosion and erosion–corrosion measurements were carried out on low temperature nitrided stainless steel AISI 316 and on low temperature nitrided stainless steel AISI 316 with a top layer of DLC. The combination of DLC and low temperature...... nitriding dramatically reduces the amount of erosion–corrosion of stainless steel under impingement of particles in a corrosive medium....

  14. Apendicitis por Paracoccidioides brasiliensis

    Directory of Open Access Journals (Sweden)

    Ana Beatriz MUÑOZ URRIBARRI

    2006-01-01

    Full Text Available La paracoccidioidomicosis es la micosis más prevalente en Sudamérica. La forma aguda afecta el sistema fagocítico mononuclear de niños y personas inmunocomprometidas. El compromiso gastrointestinal es frecuente y su patogenia implica diseminación hematógena y linfática. La linfadenomegalia abdominal causa obstrucción intestinal y abdomen agudo. En este artículo damos a conocer el caso de un niño con compromiso gastrointestinal por apendicitis. Este es el primer caso reportado de apendicitis por esta patología. (Rev Med Hered 2006;17:58-60.

  15. Reprogramación del polen a embriogénesis inducida por estrés: identidad celular, muerte celular programada y papel de la metilación de DNA

    OpenAIRE

    Solís, María Teresa

    2012-01-01

    El desarrollo del grano de polen es un proceso estrictamente regulado a nivel génico que conduce a la formación de un organismo haploide, el gametofito masculino o grano de polen, cuyas células poseen una alta especialización, necesaria para su importante función en la germinación del tubo polínico y doble fecundación de las plantas con flores. Mediante la aplicación de un tratamiento de estrés in vitro en la etapa adecuada del desarrollo, concretamente en la fase de microspora...

  16. Interval for the expression of the adaptive response induced by gamma radiation in leucocytes of mouse In vivo; Intervalo para la expresion de la respuesta adaptativa inducida por radiacion gamma en leucocitos de raton In vivo

    Energy Technology Data Exchange (ETDEWEB)

    Mendiola C, M T; Morales R, P [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2002-07-01

    The interval between the adaptive gamma radiation dose (0.01 Gy) and challenge (1.0 Gy) capable to induce the maximum expression of the adaptive response in lymphocytes of mouse In vivo. The animals were exposed to the mentioned doses with different intervals among both (1, 1.5, 5 or 18 hr). By means of the unicellular electrophoresis in gel technique, four damage parameters were analysed. The results showed that from the 1 hr interval an adaptive response was produced since in the pretreated organisms with 0.01 Gy the cells present lesser damage than in those not adapted. The maximum response was induced with the intervals between 2.5 and 5 hr and even though it persisted until 18 hr, the effect was reducing. (Author)

  17. Validation of the technique of kinetic fosforimetria induced by laser for the determination of the concentration of uranium in urine; Validacion de la tecnica de fosforimetria cinetica inducida por laser para la determinacion de la concentracion de uranio en orina

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, C.; Sierra, I.; Benito, P.; Lopez, C.

    2013-07-01

    This paper describes the methodology used to conduct the validation of the method of determination of uranium using the technique of Kinetic Phosphorescence Analyser (KPA) The technical requirements of the standard 17025 stresses the need for validation samples KPA urine of workers exposed to risk of internal contamination. (Author)

  18. Efectos de un preparado probiótico en un modelo de colitis experimental crónica en ratones, inducida por la ingesta de dextrano sulfato sódico (DSS

    Directory of Open Access Journals (Sweden)

    S Bolívar González

    2015-01-01

    Conclusión: La administración del preparado probiótico, previene o retrasa los signos externos de la colitis, así como los niveles proteicos y génicos de marcadores inflamatorios asociados a ella.

  19. Eosinophilic pneumonitis induced by aerosol-administered diesel oil and pyrethrum to mice Neumonía eosinofílica inducida por aerosol de aceite diésel y piretroide en ratones

    Directory of Open Access Journals (Sweden)

    Maria Lúcia B. Garcia

    2009-06-01

    Full Text Available OBJECTIVE: To confirm the episode of eosinophilic pneumonitis that occurred in March 2001 in Manaus, Amazon, northern Brazil, as secondary to home aerosolization with 2% cypermethrin diluted in diesel compared with the more conventional 1% cypermethrin and soybean solution used in prophylaxis of dengue. METHODS: Four groups of Swiss mice were kept in polycarbonate cages aerosolized with one of the following solutions: diesel, diesel and cypermethrin, soy oil and cypermethrin, and saline. Three and 6 days after exposure, resistance and compliance of the respiratory system and white cell kinetics in peripheral blood and lung tissue were analyzed. RESULTS: The group exposed to diesel and cypermethrin showed higher respiratory system resistance (p OBJETIVO: Confirmar el episodio de neumonía eosinofílica ocurrido en marzo de 2001 en Manaus, Amazonas, en el norte de Brasil, secundario al uso de aerosol de cipermetrina diluida al 2% en aceite diésel en las viviendas en comparación con la profilaxis más convencional contra el dengue, basada en cipermetrina al 1% con aceite de soya. MÉTODOS: Se mantuvieron cuatro grupos de ratones suizos en jaulas de policarbonato y se aplicó aerosol con una de las siguientes soluciones: aceite diésel, aceite diésel y cipermetrina, aceite de soya y cipermetrina, y solución salina. Se analizaron la resistencia y el funcionamiento del sistema respiratorio y la cinética de leucocitos en sangre periférica y tejido pulmonar a los tres y seis días después de la exposición. RESULTADOS: El grupo expuesto a aceite diésel y cipermetrina mostró mayor resistencia del sistema respiratorio (P < 0,001, peor funcionamiento (P = 0,03 y más eosinófilos en sangre (P = 0,03 y tejido pulmonar (P = 0,005 que los otros grupos. Se observó un aumento de neutrófilos en sangre en todos los grupos experimentales al tercer día después de la exposición (P < 0,001. CONCLUSIONES: El aceite diésel con cipermetrina indujo una hiperrespuesta pulmonar en este modelo experimental y se asoció con un aumento en las células polimorfonucleares (eosinófilos y neutrófilos en sangre y tejido pulmonar. Este efecto es mayor al tercer día después de la exposición. Estos efectos son similares a los observados en el episodio ocurrido en Manaus en 2001 e indican que se debe reevaluar el uso de aerosol de aceite diésel con cipermetrina para la profilaxis de arbovirus en las viviendas.

  20. Setting-up of the Laser Induced Fluorescence diagnostic. Measurements of Cr density in a neon glow discharge; Puesta a punto del diagnstico de fluorescencia inducida por laser. Medidas de densidad de Cr en Glow discharg de Neon

    Energy Technology Data Exchange (ETDEWEB)

    Tafalla, D.; Cal, E. de la; Tabares, F. L.

    1994-07-01

    A plasma diagnostic based on the Laser Induced Fluorescence (LIF) technique has been set up in the Fusion Division at the CIEMAT. In a preliminary experiment, the density of sputtered chromium atoms produced in a neon glow discharge was measured. Firstly, the laser beam was characterized by calibration of its wavelength, bandwidth and energy profile and Rayleigh scattering in N2 was used for the optical system calibration. An absolute density of Cr atoms of n {approx} 5x10 cm was obtained in discharges at 100 mA and pressure of 15 mTorr and a linear dependence of the LIF signal us. current was found. These values are in agreement with those expected from the tabulated sputtering yields and the thermalization and diffusion of the sputtered atoms into the Ne plasma. (Author) 19 refs.

  1. A review of case histories of induced seismicity caused by hydrocarbon production and storage; Revisión de la casuística sobre sismicidad inducida por producción y almacenamiento de hidrocarburos

    Energy Technology Data Exchange (ETDEWEB)

    Vadillo Fernández, L.; Fernández Naranjo, F.J.; Rodríguez Gómez, V.; López Gutiérrez, J.

    2017-09-01

    In this article we review the stress-strain relationships that take place in the crust during some of the main hydrocarbon production and storage processes: gas extraction; water injection in wells to stimulate the extraction of oil (EOR); unconventional hydrocarbon production by hydraulic fracturing (fracking); disposal of wastewater (saline water) from the extraction of conventional and unconventional hydrocarbons such as saline water return (flowback) of hydraulic fracturing, both with TDS higher than 40000 mg/L. In addition, the type of faults that are more likely to slip and the induced seismicity related to the production and extraction of hydrocarbons are analysed. [Spanish] En este artículo se revisan los procesos de tensión que se producen en la corteza durante: la extracción de gas; en el almacenamiento de gas; en la inyección de fluidos (agua, CO2) para estimular la extracción de hidrocarburos convencionales (EOR); en la extracción de hidrocarburos no convencionales con inyección de agua a presión y fracturación hidráulica (fracking); y en la eliminación, mediante inyección, del agua salina (produced water) procedente de la extracción de hidrocarburos convencionales, así como del agua salina de retorno (flowback) de la fracturación hidráulica de la explotación de hidrocarburos no convencionales, ambas con más de 40000 mg/L de Sólidos Totales Disueltos (TDS). Asimismo se revisa la tipología de fallas más propensas a sufrir deslizamientos y la sismicidad relacionada con cada uno de los casos anteriormente descritos consecuencia del aumento de la presión de poro durante la inyección y la disminución de la presión de poro durante al extracción.

  2. Evaluation of the recombination in somatic cells induced by radiation in different stages of Drosophila larval development; Evaluacion de la recombinacion en celulas somaticas inducida por radiacion en diferentes etapas del desarrollo larvario de Drosophila

    Energy Technology Data Exchange (ETDEWEB)

    Cruces, M P; Morales R, P [Instituto nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    1997-07-01

    The mitotic recombination can happen spontaneously and its frequency is very low, however the recombination rate of a cell can be increased by the exposure to agents which cause damage to DNA. This type of agents are knew commonly as recombinogens. The ionizing radiation and a numerous chemical agents can be mentioned (Vogel, 1992). The objective of this work is to determine if the mutation/recombination rate induced by gamma rays varies with the development stage. In order to realize this investigation it was used the mutation and somatic recombination test of Drosophila wing (Graf and col. 1984). The mwh/ mwh and flr{sup 3}/TM3, Ser stocks were used. (Author)

  3. First Patagonian Course on 'Diagnosis and Therapy of Injuries Induced by Ionizing Radiation'; Primer curso patagonico 'Diagnostico y Tratamiento de Lesiones Inducidas por Radiaciones Ionizantes'

    Energy Technology Data Exchange (ETDEWEB)

    Bellotti, Mariela I., E-mail: bellotti@cab.cnea.gov.ar [Comision Nacional de Energia Atomica (CAB/CNEA), San Carlos de Bariloche (Argentina). Centro Atomico Bariloche. Lab. de Cavitacion y Biotecnologia; Andres, Pablo A., E-mail: andresp@cab.cnea.gov.ar [Comision Nacional de Energia Atomica (CAB/CNEA), San Carlos de Bariloche (Argentina). Centro Atomico Bariloche. Division Proteccion Radiologica; Cascón, Adriana S., E-mail: adrianacascon@yahoo.com [Instituto de Medicina, Radiomedicina y Seguridad (IMERASE SA), Buenos Aires, (Argentina)

    2013-07-01

    In Patagonia there are academic centers, health and industrial facilities that use ionizing radiations in its usual practices. However, they do not have protocols that respond to local needs. For this reason was held from October 5 to November 10, 2012 in Bariloche Atomic Center, a training course for health personnel. The range of topics covered ranged from the definition of dosimetry quantities, types of radiation and biological dosimetry, biological effects, radiation acute syndrome, radiation-induced cutaneous syndrome, internal contamination, screening in radiological emergencies, etc.The course provided a theoretical and practical guide about how to recognize and treat people exposed to radiations, guidelines for acting in radiological emergencies and a perception of the psychosocial impact of the radiation accidents.The result was a pocket book for health personnel that will be used in case of having a patient with radiation induced injury.

  4. Influence of temperature in TL signal induced by gamma radiation in zircon prepared by sol gel via; Influencia de la temperatura en la senal TL inducida por la radiacion gamma en zirconia preparada via solgel

    Energy Technology Data Exchange (ETDEWEB)

    Salas, P.; Castano, V.M. [Instituto de Fisica, UNAM, Laboratorio Juriquilla, A.P. 1-1010, 76001 Queretaro (Mexico); Mendoza A, D.; Gonzalez M, P.R. [ININ, Mexico, D.F. (Mexico); Rosa C, E. de la [Centro de Investigaciones en Optical, Leon, Gto. (Mexico)

    2000-07-01

    In this work, it was realized a study of the temperature effects in thermoluminescent signal (Tl) induced by gamma radiation in zircon, which was prepared by the sol gel method. According to the obtained results, the zircon thermically treated at 500 C or over is sensitive to radiation. This sensitivity is increased when the temperature in study is augmented, moreover, the Tl spectra form also is modified with the temperature increment. The samples thermically treated at 750 C or over present a linear response in the dose interval 27 to 165 Gy; therefore, such materials result promissories for dosimetric purposes. (Author)

  5. Microstructural characteristics of the hydroxyapatite and its influence in the Tl signal induced by gamma radiation; Caracteristicas microestructurales de la hidroxiapatita y su influencia en la senal Tl inducida por la radiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza A, D.; Gonzalez M, P.R.; Hernandez A, M. [ININ, A.P. 18-1027, 11801 Mexico D.F. (Mexico); Estrada G, R. [Depto. de Fisica y Matematicas, Universidad Iberoamericana, Santa Fe, 01000 Mexico D.F. (Mexico); Rodriguez L, V. [Centro Universitario de Vinculacion, BUAP, Puebla (Mexico)

    2003-07-01

    The analysis carried out on different materials has shown that the quantity and type of dopants play an important role in the behaviour thermoluminescent signal induced by the ionizing radiation. More recent studies have also shown that the grain size influences strongly in the thermoluminescent signal. Plus still, the crystal growth habit and the crystalline degree have an important effect in the type and intensity thermoluminescent signal. In this sense, we present this work on the analysis of the thermoluminescent signal induced by the gamma radiation in the hydroxyapatite ceramic. Depending the growth habit, a variation of the peak temperature location, signal intensity and linearity range was observed; in particular cases a lineal relationship between glow curve and radiation dose was in the range from 2 to 1000 Gray. These results are complemented with a microstructural and crystalline degree analysis through scanning electron microscopy and X-ray Diffraction. The dose-response over the whole irradiation range opening up the possibility of employing this bio material as a dosimeter. (Author)

  6. Estudio del receptor 5HT2A y de la vía Akt/GSK3 como mecanismos moleculares de la psicosis inducida por el consumo crónico de cannabis

    OpenAIRE

    Ibarra Lecue, Inés

    2015-01-01

    La esquizofrenia es una enfermedad mental de carácter crónico que afecta aproximadamente al 1% de la población , principalmente con edades comprendidas entre los 15 y 4 5 años . Se trata de una enfermedad de inicio en la adolescencia o comienzo de la madurez y cuyo potencial discapacitante persiste y se agrava a lo largo de la vida. La etiología de la esquizofrenia es multifactorial con evidencias de factores genéticos y ambientales. El carácter hereditario de la...

  7. Microbiologically Influenced Corrosion: Causative Organisms and Mechanisms

    Science.gov (United States)

    2012-01-31

    enviromental composition as a potential method for reversing microbiologically influenced corrosion, Corrosion (NAC’E) International. Houston. Texas...International fellow and associate editor for Biofouling, The Journal of Bioadhesion and Biofilm Research. J. Lee is a Materials and Corrosion Engineer

  8. Corrosion and chemical resistant masonry materials handbook

    National Research Council Canada - National Science Library

    Sheppard, Walter Lee

    1986-01-01

    ... and other equipment. But few other than chemists and chemical engineers identify "corrosion" as chemical degradation or destruction of a material, and therefore, something that can happen to nonmetals (concrete, plastics, brick, timber, etc.) as well as to nletals. The National Association of Corrosion Engineers so defined "corrosion" over thirty years ago but this f...

  9. Corrosion of reinforcement induced by environment containing ...

    Indian Academy of Sciences (India)

    Unknown

    carbonation and chlorides causing corrosion of steel reinforcement. ... interesting and important when the evaluation of the service life of the ... preferably in the areas of industrial and transport activities. ... For controlling the embedded corrosion sensors, elec- .... danger of corrosion of reinforcement seems to be more.

  10. Solutions of corrosion Problems in advanced Technologies

    DEFF Research Database (Denmark)

    Montgomery, Melanie; Karlsson, Asger

    1999-01-01

    Austenitic and ferritic steels were exposed in the superheater area of a straw-fired CHP plant. The specimens were exposed for 1400 hours at 450-600°C. The rate of corrosion was assessed based on unattacked metal remaining. The corrosion products and course of corrosion for the various steel types...

  11. Corrosion resistance of zirconium in nitric acid

    International Nuclear Information System (INIS)

    Kajimura, H.; Morikawa, H.; Nagano, H.

    1987-01-01

    Slow strain rate tests are effected on zirconium in boiling nitric acid to study the influence of nitric acid concentration, of oxidizing ions (Cr and Ce) and of electric potential. Corrosion resistance is excellent and stress corrosion cracking occurs only for severe conditions: 350 mV over electric potential for corrosion with nitric acid concentration of 40 % [fr

  12. Morphological kinetics and localized corrosion

    International Nuclear Information System (INIS)

    Santarini, G.

    1992-01-01

    A phenomenological modeling is proposed for physicochemical systems that evolve by initiation and growth of well distinct defects. It consists in a mathematical treatment of data on the evolution of defect distribution, which leads to the knowledge of evolution parameters ultimately usable for behaviour predictions. A method is given for calculating a validity parameter which quantifies the pertinence of the choice for analytical representations. An example of application to localized corrosion is given with the intergranular stress corrosion cracking of Alloy 600 in high temperature water. (Author). 6 refs

  13. High temperature corrosion in gasifiers

    Directory of Open Access Journals (Sweden)

    Bakker Wate

    2004-01-01

    Full Text Available Several commercial scale coal gasification combined cycle power plants have been built and successfully operated during the last 5-10 years. Supporting research on materials of construction has been carried out for the last 20 years by EPRI and others. Emphasis was on metallic alloys for heat exchangers and other components in contact with hot corrosive gases at high temperatures. In this paper major high temperature corrosion mechanisms, materials performance in presently operating gasifiers and future research needs will be discussed.

  14. Synergy effect of naphthenic acid corrosion and sulfur corrosion in crude oil distillation unit

    Energy Technology Data Exchange (ETDEWEB)

    Huang, B.S., E-mail: yinwenfeng2010@163.com [College of Materials Science and Engineering, Southwest Petroleum University, Sichuan, Chengdu, 610500 (China); Yin, W.F. [College of Mechatronic Engineering, Southwest Petroleum University, Sichuan, Chengdu, 610500 (China); Sang, D.H. [Sheng Li Construction Group International Engineering Department, Shandong, Dongying, 257000 (China); Jiang, Z.Y. [College of Materials Science and Engineering, Southwest Petroleum University, Sichuan, Chengdu, 610500 (China)

    2012-10-15

    Highlights: Black-Right-Pointing-Pointer The corrosion of a carbon-manganese steel and a stainless steel in sulfur and/or naphthenic acid media was investigated. Black-Right-Pointing-Pointer The corrosion rate of the carbon-manganese steel increased with the increase of the acid value and sulfur content. Black-Right-Pointing-Pointer The critical values of the concentration of sulfur and acid for corrosion rate of the stainless steel were ascertained respectively. Black-Right-Pointing-Pointer The stainless steel is superior to the carbon-manganese steel in corrosion resistance because of the presence of stable Cr{sub 5}S{sub 8} phases. - Abstract: The synergy effect of naphthenic acid corrosion and sulfur corrosion at high temperature in crude oil distillation unit was studied using Q235 carbon-manganese steel and 316 stainless steel. The corrosion of Q235 and 316 in corrosion media containing sulfur and/or naphthenic acid at 280 Degree-Sign C was investigated by weight loss, scanning electron microscope (SEM), EDS and X-ray diffractometer (XRD) analysis. The results showed that in corrosion media containing only sulfur, the corrosion rate of Q235 and 316 first increased and then decreased with the increase of sulfur content. In corrosion media containing naphthenic acid and sulfur, with the variations of acid value or sulfur content, the synergy effect of naphthenic acid corrosion and sulfur corrosion has a great influence on the corrosion rate of Q235 and 316. It was indicated that the sulfur accelerated naphthenic acid corrosion below a certain sulfur content but prevented naphthenic acid corrosion above that. The corrosion products on two steels after exposure to corrosion media were investigated. The stable Cr{sub 5}S{sub 8} phases detected in the corrosion products film of 316 were considered as the reason why 316 has greater corrosion resistance to that of Q235.

  15. Corrosion and corrosion protection of support structures for offshore wind energy devices (OWEA)

    Energy Technology Data Exchange (ETDEWEB)

    Momber, A. [Muehlhan AG, Schlinckstrasse 3, D-21107 Hamburg (Germany)

    2011-05-15

    The paper provides a review about the corrosion and corrosion protection of offshore wind energy devices (OWEA). Firstly, special features resulting from location and operation of OWEA are being discussed. Secondly, types of corrosion and corrosion phenomena are summarized in a systematic way. Finally, practical solutions to the corrosion protection of OWEA, including steel allowances, cathodic protection and coatings and linings, are discussed. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  16. EVOLUCIÓN DEL COMPORTAMIENTO VISCOELÁSTICO DEL ASFALTO INDUCIDA BAJO TERMO-OXIDACIÓN IN SITU EN UN REO-REACTOR

    Directory of Open Access Journals (Sweden)

    XIOMARA VARGAS

    2008-01-01

    Full Text Available En este artículo se presentan los resultados del proceso de termo-oxidación de asfalto realizados por primera vez en un reo-reactor. El comportamiento viscoelástico del asfalto pudo ser representado por una ley de potencia (G'(w - wn, G'' (w - w1. La variación del exponente 'n' reflejó los cambios estructurales del asfalto inducidos por el proceso de termo-oxidación. En el intervalo de frecuencia experimental y a 200 y 250°C, los módulos elástico G' y viscoso G'' mostraron una relación del tipo: G'' (w - wn y G' (w ~ wn, este comportamiento es equivalente a un 'gel-débil' y confirma los cambios estructurales del asfalto inducidos por el envejecimiento termo-oxidativo.

  17. Toxicidad hepática por medicamentos antituberculosos Hepatotoxicity induced by antituberculosis drugs

    Directory of Open Access Journals (Sweden)

    Isabel Eugenia Escobar Toledo

    2008-01-01

    Full Text Available

    El fenómeno de la toxicidad hepática inducida por medicamentos cobró relevancia hace algunos años con el estudio de las reacciones adversas a medicamentos. El daño producido en el hígado por un xenobiótico que altera su función es lo que se conoce como toxicidad hepática. La importancia de reconocer y diagnosticar la toxicidad hepática por medicamentos estriba en su gravedad potencial; no en vano es la causa más frecuente por la que la industria farmacéutica retira medicamentos. La tuberculosis es una pandemia que afecta a gran parte de la población mundial y junto con el VIH es una enfermedad cada vez más frecuente en Colombia. Esta enfermedad se puede considerar como una situación especial porque para su tratamiento es preciso suministrar, por largos períodos, medicamentos con potencial tóxico para el hígado.

     

    El objetivo de este artículo es revisar algunos aspectos relacionados con la toxicidad hepática secundaria a medicamentos antituberculosos, tales como: epidemiología, factores de riesgo, mecanismos de toxicidad, manifestaciones clínicas, diagnóstico, tratamiento y seguimiento.

    Hepatotoxicity is the alteration of liver structure and function induced by either drugs or other substances. The importance of its proper diagnosis rests on its potential severity. It is the most frequent reason by which the pharmaceutical industry withdraws its products. Tuberculosis is a pandemic infection affecting a large proportion of the world population. Together with HIV infection it is becoming ever more frequent in Colombia. Tuberculosis poses

  18. 219-S CORROSION STUDY

    International Nuclear Information System (INIS)

    DIVINE, J.R.; PARSONS, G.L.

    2008-01-01

    A minor leak was detected in a drain line for Hood 2B located in the 222-S Laboratory. The line transfers radioactive waste, spent analytical standards, and chemicals used in various analytical procedures. Details are in the report provided by David Comstock, 2B NDE June 2008, work package LAB-WO-07-2012. Including the noted leak, the 222-S Laboratory has experienced two drain line leaks in approximately the last two years of operation. As a consequence, CH2M HILL Hanford Group, Inc. (CH2M HILL) requested the support of ChemMet, Ltd., PC (ChemMet) at the Hanford Site 222-S Laboratory. The corrosion expertise from ChemMet was required prior to preparation of a compatibility assessment for the 222-S Laboratory waste transfer system to assure the expected life of the piping system is extended as much as practicable. The system includes piping within the 222-S Laboratory and the 219-S Waste Storage and Transfer Facility and Operations Process. The ChemMet support was required for an assessment by 222-S staff to analyze what improvements to operational activities may be implemented to extend the tank/piping system life. This assessment will include a summary of the various material types, age, and locations throughout the facility. The assessment will also include a discussion of materials that are safe for drain line disposal on a regular basis, materials that are safe for disposal on a case-by-case basis including specific additional requirements such as flushing, neutralization to a specific pH, and materials prohibited from disposal. The assessment shall include adequate information for 222-S Laboratory personnel to make informed decisions in the future disposal of specific material types by discussing types of compatibility of system materials and potential wastes. The assessment is expected to contain some listing of acceptable waste materials but is not anticipated to be a complete or comprehensive list. Finally the assessment will encompass a brief discussion of

  19. EUROCORR 2007 - The European corrosion congress - Progress by corrosion control. Book of Abstracts

    International Nuclear Information System (INIS)

    2007-01-01

    This book of abstracts contains lectures, workshops and posters which were held on the European Corrosion Congress 2007 in Freiburg (Germany). The main topics of the sessions and posters are: 1. Corrosion and scale inhibition; 2. Corrosion by hot gases and combustion products; 3. Nuclear corrosion; 4. Environment sensitive fracture; 5. Surface Science; 6. Physico-chemical methods of corrosion testing; 7. Marine corrosion; 8. Microbial corrosion; 9. Corrosion of steel in concrete; 10. Corrosion in oil and gas production; 11. Coatings; 12. Corrosion in the refinery industry; 13. Cathodic protection; 14. Automotive Corrosion; 15. Corrosion of polymer materials. The main topics of the workshops are: 1. High temperature corrosion in the chemical, refinery and petrochemical industries; 2. Bio-Tribocorrosion; 3. Stress corrosion cracking in nuclear power plants; 4. Corrosion monitoring in nuclear systems; 5. Cathodic protection for marine and offshore environments; 6. Self-healing properties of new surface treatments; 7. Bio-Tribocorrosion - Cost 533/Eureka-ENIWEP-Meeting; 8. Drinking water systems; 9. Heat exchangers for seawater cooling

  20. General Corrosion and Localized Corrosion of Waste Package Outer Barrier

    Energy Technology Data Exchange (ETDEWEB)

    Farmer, J.C.; McCright, R.D.

    2000-01-28

    Alloy 22 is an extremely Corrosion Resistant Material, with a very stable passive film. Based upon exposures in the LTCTF, the GC rates of Alloy 22 are typically below the level of detection, with four outliers having reported rates up to 0.75 #mu#m per year. In any event, over the 10,000 year life of the repository, GC of the Alloy 22 (assumed to be 2 cm thick) should not be life limiting. Because measured corrosion potentials are far below threshold potentials, localized breakdown of the passive film is unlikely under plausible conditions, even in SSW at 120 deg C. The pH in ambient-temperature crevices formed from Alloy 22 have been determined experimentally, with only modest lowering of the crevice pH observed under plausible conditions. Extreme lowering of the crevice pH was only observed under situations where the applied potential at the crevice mouth was sufficient to result in catastrophic breakdown of the passive film above the threshold potential in non-buffered conditions not characteristic of the Yucca Mountain environment. In cases where naturally ocurring buffers are present in the crevice solution, little or no lowering of the pH was observed, even with significant applied potential. With exposures of twelve months, no evidence of crevice corrosion has been observed in SDW, SCW and SAW at temperatures up to 90 deg C. An abstracted model has been presented, with parameters determined experimentally, that should enable performance assessment to account for the general and localized corrosion of this material. A feature of this model is the use of the materials specification to limit the range of corrosion and threshold potentials, thereby making sure that substandard materials prone to localized attack are avoided. Model validation will be covered in part by a companion SMR on abstraction of this model.

  1. Liquid metal corrosion considerations in alloy development

    International Nuclear Information System (INIS)

    Tortorelli, P.F.; DeVan, J.H.

    1984-01-01

    Liquid metal corrosion can be an important consideration in developing alloys for fusion and fast breeder reactors and other applications. Because of the many different forms of liquid metal corrosion (dissolution, alloying, carbon transfer, etc.), alloy optimization based on corrosion resistance depends on a number of factors such as the application temperatures, the particular liquid metal, and the level and nature of impurities in the liquid and solid metals. The present paper reviews the various forms of corrosion by lithium, lead, and sodium and indicates how such corrosion reactions can influence the alloy development process

  2. Corrosion measurement using flux gate magnetometer

    International Nuclear Information System (INIS)

    Rashdi Shah Ahmad; Chong Cheong Wei

    2001-01-01

    The ability of fluxgate magnetometer to detect and measure quantitatively the magnetic field generated by electrochemical corrosion is presented. In this study, each sample (iron plate) was exposed to a range of increasingly corrosive environment. During the exposure, we measured the magnetic field above the sample for specific duration of time. The result shows that there is a clear relationship between corrosivity of the environment and the change in magnitude of magnetic field that was generated by the corrosion reaction. Therefore, the measurement of magnetic field might be used to determine the corrosion rates. (Author)

  3. Nodular Corrosion Characteristics of Zirconium Alloys

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Gil; Jeong, Y. H.; Park, S. Y.; Lee, D. J

    2003-01-15

    This study was reported the effect of the nodular corrosion on the nuclear reactor environmental along with metallurgical influence, also suggested experimental scheme related to evaluate nodular corrosion characteristics of Zr-1 Nb alloy. Remedial strategies against the nodular corrosion should firstly develop plan to assess the effect of the water quality condition (Oxygen, Hydrogen) as well as the boiling on the nodular corrosion, secondarily establish plan to control heat treatment process to keep a good resistance on nodular corrosion in Zr-1Nb alloy as former western reactor did.

  4. Assessing Level and Effectiveness of Corrosion Education in the UAE

    Directory of Open Access Journals (Sweden)

    Hwee Ling Lim

    2012-01-01

    Full Text Available The consequences of corrosion can be minimized by an engineering workforce well trained in corrosion fundamentals and management. Since the United Arab Emirates incurs the second highest cost of corrosion after Saudi Arabia, this paper examined the quality of corrosion education in the UAE. Surveys with academia and industry respondents showed that dedicated corrosion courses and engineering courses that integrated corrosion into the curricula were available in UAE universities, but graduates had insufficient knowledge of corrosion engineering and superficial understanding of corrosion in real-life design contexts. The effectiveness of corrosion education is determined by both competence in corrosion knowledge/skills and availability of resources (faculty and research. Though most departments would not hire new corrosion-specialist faculty, department research efforts and industry partnerships in corrosion research were present. The paper concluded with recommendations for improving knowledge and skills of future engineers in corrosion and enhancing corrosion instruction to better meet industry needs.

  5. Erosion corrosion in wet steam

    International Nuclear Information System (INIS)

    Tavast, J.

    1988-03-01

    The effect of different remedies against erosion corrosion in wet steam has been studied in Barsebaeck 1. Accessible steam systems were inspected in 1984, 1985 and 1986. The effect of hydrogen peroxide injection of the transport of corrosion products in the condensate and feed water systems has also been followed through chemical analyses. The most important results of the project are: - Low alloy chromium steels with a chromium content of 1-2% have shown excellent resistance to erosion corrosion in wet steam. - A thermally sprayed coating has shown good resistance to erosion corrosion in wet steam. In a few areas with restricted accessibility minor attacks have been found. A thermally sprayed aluminium oxide coating has given poor results. - Large areas in the moisture separator/reheater and in steam extraction no. 3 have been passivated by injection of 20 ppb hydrogen peroxide to the high pressure steam. In other inspected systems no significant effect was found. Measurements of the wall thickness in steam extraction no. 3 showed a reduced rate of attack. - The injection of 20 ppb hydrogen peroxide has not resulted in any significant reduction of the iron level result is contrary to that of earlier tests. An increase to 40 ppb resulted in a slight decrease of the iron level. - None of the feared disadvantages with hydrogen peroxide injection has been observed. The chromium and cobalt levels did not increase during the injection. Neither did the lifetime of the precoat condensate filters decrease. (author)

  6. Corrosion of austenitic stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Silva, M C.M. [Instituto Nacional de Tecnologia, Rio de Janeiro (Brazil)

    1977-01-01

    Types of corrosion observed in a heat exchanger pipe and on a support of still of molasses fermented wort, both in austenitic stainless steel, are focused. Not only are the causes which might have had any kind of influence on them examined, but also the measures adopted in order to avoid and lessen its occurence.

  7. Automated methods of corrosion measurement

    DEFF Research Database (Denmark)

    Andersen, Jens Enevold Thaulov; Bech-Nielsen, Gregers; Reeve, John Ch

    1997-01-01

    to revise assumptions regarding the basis of the method, which sometimes leads to the discovery of as-yet unnoticed phenomena. The present selection of automated methods for corrosion measurements is not motivated simply by the fact that a certain measurement can be performed automatically. Automation...... is applied to nearly all types of measurements today....

  8. Stress corrosion in gaseous environment

    International Nuclear Information System (INIS)

    Miannay, Dominique.

    1980-06-01

    The combined influences of a stress and a gaseous environment on materials can lead to brittleness and to unexpected delayed failure by stress corrosion cracking, fatigue cracking and creep. The most important parameters affering the material, the environment, the chemical reaction and the stress are emphasized and experimental works are described. Some trends for further research are given [fr

  9. Apendicitis por Paracoccidioides brasiliensis.

    OpenAIRE

    MUÑOZ URRIBARRI, Ana Beatriz; CHAPARRO DAMMERT, Eduardo; FERRUFINO LLACH, Juan Carlos; VASQUEZ FLORES, Luciola

    2012-01-01

    La paracoccidioidomicosis es la micosis más prevalente en Sudamérica. La forma aguda afecta el sistema fagocítico mononuclear de niños y personas inmunocomprometidas. El compromiso gastrointestinal es frecuente y su patogenia implica diseminación hematógena y linfática. La linfadenomegalia abdominal causa obstrucción intestinal y abdomen agudo. En este artículo damos a conocer el caso de un niño con compromiso gastrointestinal por apendicitis. Este es el primer caso reportado de apendicitis p...

  10. Meningitis por Streptococcus suis

    OpenAIRE

    Geffner Sclarsky, D. E.; Moreno Muñoz, R.; Campillo Alpera, Mª.S.; Pardo Serrano, F.J.; Gómez Gómez, A.; Martínez-Lozano, Mª.D.

    2001-01-01

    La infección humana por Streptococcus suis (S. suis) es una zoonosis, con un riesgo ocupacional conocido y que suele presentarse como meningitis purulenta, que tiene baja mortalidad y frecuentes secuelas de hipoacusia y ataxia. Se han publicado menos de 150 casos humanos desde el informe original de hace 30 años. Hay una reconocida distribución geográfica viviendo la mayoría de los afectados en el norte de Europa y el sudeste Asiático. En España se han comunicado dos pacientes con enfermedad ...

  11. Por mil devaluados pesos

    Directory of Open Access Journals (Sweden)

    Annie Rodríguez Collázos

    2013-03-01

    Full Text Available El estudio de lo popular y lo urbano hasta ahora se ha centrado en el comportamiento y en algunas relaciones de los habitantes con su entorno. “Por mil devaluados pesos. Publicidad popular y urbana”, pretende explorar las formas de publicidad, dispersas en diferentes espacios populares y urbanos en Bogotá, identificando esquemas y formas características de sus propios códigos comunicativos; se centran en un objeto de estudio consistente en las estrategias publicitarias y los códigos comunicativos en los mensajes publicitarios populares en las subculturas de San Victorino, 7 de Agosto y Sanandresito de San José.

  12. The dual role of microbes in corrosion.

    Science.gov (United States)

    Kip, Nardy; van Veen, Johannes A

    2015-03-01

    Corrosion is the result of a series of chemical, physical and (micro) biological processes leading to the deterioration of materials such as steel and stone. It is a world-wide problem with great societal and economic consequences. Current corrosion control strategies based on chemically produced products are under increasing pressure of stringent environmental regulations. Furthermore, they are rather inefficient. Therefore, there is an urgent need for environmentally friendly and sustainable corrosion control strategies. The mechanisms of microbially influenced corrosion and microbially influenced corrosion inhibition are not completely understood, because they cannot be linked to a single biochemical reaction or specific microbial species or groups. Corrosion is influenced by the complex processes of different microorganisms performing different electrochemical reactions and secreting proteins and metabolites that can have secondary effects. Information on the identity and role of microbial communities that are related to corrosion and corrosion inhibition in different materials and in different environments is scarce. As some microorganisms are able to both cause and inhibit corrosion, we pay particular interest to their potential role as corrosion-controlling agents. We show interesting interfaces in which scientists from different disciplines such as microbiology, engineering and art conservation can collaborate to find solutions to the problems caused by corrosion.

  13. The dual role of microbes in corrosion

    Science.gov (United States)

    Kip, Nardy; van Veen, Johannes A

    2015-01-01

    Corrosion is the result of a series of chemical, physical and (micro) biological processes leading to the deterioration of materials such as steel and stone. It is a world-wide problem with great societal and economic consequences. Current corrosion control strategies based on chemically produced products are under increasing pressure of stringent environmental regulations. Furthermore, they are rather inefficient. Therefore, there is an urgent need for environmentally friendly and sustainable corrosion control strategies. The mechanisms of microbially influenced corrosion and microbially influenced corrosion inhibition are not completely understood, because they cannot be linked to a single biochemical reaction or specific microbial species or groups. Corrosion is influenced by the complex processes of different microorganisms performing different electrochemical reactions and secreting proteins and metabolites that can have secondary effects. Information on the identity and role of microbial communities that are related to corrosion and corrosion inhibition in different materials and in different environments is scarce. As some microorganisms are able to both cause and inhibit corrosion, we pay particular interest to their potential role as corrosion-controlling agents. We show interesting interfaces in which scientists from different disciplines such as microbiology, engineering and art conservation can collaborate to find solutions to the problems caused by corrosion. PMID:25259571

  14. Corrosion engineering in nuclear power industry

    International Nuclear Information System (INIS)

    Prazak, M.; Tlamsa, J.; Jirousova, D.; Silber, K.

    1990-01-01

    Corrosion problems in nuclear power industry are discussed from the point of view of anticorrosion measures, whose aim is not only increasing the lifetime of the equipment but, first of all, securing ecological safety. A brief description is given of causes of corrosion damage that occurred at Czechoslovak nuclear power plants and which could have been prevented. These involve the corrosion of large-volume radioactive waste tanks made of the CSN 17247 steel and of waste piping of an ion exchange station made of the same material, a crack in a steam generator collector, contamination of primary circuit water with iron, and corrosion of CrNi corrosion-resistant steel in a spent fuel store. It is concluded that if a sufficient insight into the corrosion relationships exists and a reasonable volume of data is available concerning the corrosion state during the nuclear facility performance, the required safety can be achieved without adopting extremely costly anticorrosion measures. (Z.M.)

  15. Corrosion Rate Monitoring in District Heating Systems

    DEFF Research Database (Denmark)

    Hilbert, Lisbeth Rischel; Nielsen, Lars Vendelbo; Andersen, A.

    2005-01-01

    be applicable, and if on-line monitoring could improve the quality control. Water quality monitoring was applied as well as corrosion rate monitoring with linear polarization resistance (LPR), electrochemical impedance spectroscopy (EIS), electrical resistance (ER) technique, mass loss and a crevice corrosion......Quality control in district heating systems to keep uniform corrosion rates low and localized corrosion minimal is based on water quality control. Side-stream units equipped with carbon steel probes for online monitoring were mounted in district heating plants to investigate which techniques would...... cell for localized corrosion risk estimation. Important variations in corrosion rate due to changes in make-up water quality were detected with the continuous monitoring provided by ER and crevice cell, while LPR gave unreliable corrosion rates. The acquisition time of two-three days for EIS...

  16. Evolutionary Computation Techniques for Predicting Atmospheric Corrosion

    Directory of Open Access Journals (Sweden)

    Amine Marref

    2013-01-01

    Full Text Available Corrosion occurs in many engineering structures such as bridges, pipelines, and refineries and leads to the destruction of materials in a gradual manner and thus shortening their lifespan. It is therefore crucial to assess the structural integrity of engineering structures which are approaching or exceeding their designed lifespan in order to ensure their correct functioning, for example, carrying ability and safety. An understanding of corrosion and an ability to predict corrosion rate of a material in a particular environment plays a vital role in evaluating the residual life of the material. In this paper we investigate the use of genetic programming and genetic algorithms in the derivation of corrosion-rate expressions for steel and zinc. Genetic programming is used to automatically evolve corrosion-rate expressions while a genetic algorithm is used to evolve the parameters of an already engineered corrosion-rate expression. We show that both evolutionary techniques yield corrosion-rate expressions that have good accuracy.

  17. Corrosion mechanism applicable to biodegradable magnesium implants

    Energy Technology Data Exchange (ETDEWEB)

    Atrens, Andrej, E-mail: Andrejs.Atrens@uq.edu.au [University of Queensland, Division of Materials, Brisbane, Qld 4072 (Australia); Liu Ming; Zainal Abidin, Nor Ishida [University of Queensland, Division of Materials, Brisbane, Qld 4072 (Australia)

    2011-12-15

    Much of our understanding of the Mg corrosion mechanism is based on research using aggressive chloride based solutions like 3% NaCl, which are appropriate for understand the corrosion for applications such as auto construction. The chloride ions tend to cause break down of the partly protective surface film on the Mg alloy surface. The corrosion rate increases with exposure time until steady state is reached, which may take several weeks. An overview is provided of the aspects which determine the corrosion of Mg alloys: (i) measurement details; (ii) impurity elements Fe, Ni, Cu and Co; (iii) second phases; (iv) surface films and surface condition and (v) stress corrosion cracking (SCC). This understanding is used to help understand Mg corrosion for Mg as a biodegradable implant for medical applications. Solutions that elucidate these applications tend to form surface films and the corrosion rate tends to decrease with immersion time.

  18. Predicting the Performance of Organic Corrosion Inhibitors

    Directory of Open Access Journals (Sweden)

    David A. Winkler

    2017-12-01

    Full Text Available The withdrawal of effective but toxic corrosion inhibitors has provided an impetus for the discovery of new, benign organic compounds to fill that role. Concurrently, developments in the high-throughput synthesis of organic compounds, the establishment of large libraries of available chemicals, accelerated corrosion inhibition testing technologies, and the increased capability of machine learning methods have made discovery of new corrosion inhibitors much faster and cheaper than it used to be. We summarize these technical developments in the corrosion inhibition field and describe how data-driven machine learning methods can generate models linking molecular properties to corrosion inhibition that can be used to predict the performance of materials not yet synthesized or tested. We briefly summarize the literature on quantitative structure–property relationships models of small organic molecule corrosion inhibitors. The success of these models provides a paradigm for rapid discovery of novel, effective corrosion inhibitors for a range of metals and alloys in diverse environments.

  19. Corrosion Control in the Aerospace Industry

    Science.gov (United States)

    Calle, Luz Marina; Li, Wenyan; Buhrow, Jerry W.; Johnsey, Marissa N.

    2016-01-01

    Nearly all metals and their alloys are subject to corrosion that causes them to lose their structural integrity or other critical functionality. It is essential to detect corrosion when it occurs, and preferably at its early stage, so that action can be taken to avoid structural damage or loss of function. Protective coatings are the most commonly used method of corrosion control. However, progressively stricter environmental regulations have resulted in the ban of many commercially available corrosion protective coatings due to the harmful effects of their solvents or corrosion inhibitors. This work concerns the development of a multifunctional, smart coating for the autonomous control of corrosion. This coating is being developed to have the inherent ability to detect the chemical changes associated with the onset of corrosion and respond autonomously to indicate it and control it..

  20. Corrosion of Metal-Matrix Composites with Aluminium Alloy Substrate

    Directory of Open Access Journals (Sweden)

    B. Bobic

    2010-03-01

    Full Text Available The corrosion behaviour of MMCs with aluminium alloy matrix was presented. The corrosion characteristics of boron-, graphite-, silicon carbide-, alumina- and mica- reinforced aluminium MMCs were reviewed. The reinforcing phase influence on MMCs corrosion rate as well as on various corrosion forms (galvanic, pitting, stress corrosion cracking, corrosion fatique, tribocorrosion was discussed. Some corrosion protection methods of aluminium based MMCs were described

  1. NASA's Corrosion Technology Laboratory at the Kennedy Space Center: Anticipating, Managing, and Preventing Corrosion

    Science.gov (United States)

    Calle, Luz Marina

    2015-01-01

    The marine environment at NASAs Kennedy Space Center (KSC) has been documented by ASM International (formerly American Society for Metals) as the most corrosive in North America. With the introduction of the Space Shuttle in 1981, the already highly corrosive conditions at the launch pads were rendered even more severe by the highly corrosive hydrochloric acid (HCl) generated by the solid rocket boosters (SRBs). Numerous failures at the launch pads are caused by corrosion. The structural integrity of ground infrastructure and flight hardware is critical to the success, safety, cost, and sustainability of space missions. NASA has over fifty years of experience dealing with unexpected failures caused by corrosion and has developed expertise in corrosion control in the launch and other environments. The Corrosion Technology Laboratory at KSC evolved, from what started as an atmospheric exposure test site near NASAs launch pads, into a capability that provides technical innovations and engineering services in all areas of corrosion for NASA, external partners, and customers.This paper provides a chronological overview of NASAs role in anticipating, managing, and preventing corrosion in highly corrosive environments. One important challenge in managing and preventing corrosion involves the detrimental impact on humans and the environment of what have been very effective corrosion control strategies. This challenge has motivated the development of new corrosion control technologies that are more effective and environmentally friendly. Strategies for improved corrosion protection and durability can have a huge impact on the economic sustainability of human spaceflight operations.

  2. Future and benefits of corrosion research

    International Nuclear Information System (INIS)

    Staehle, Roger W.

    2002-01-01

    The subject of corrosion is a design science. The subject of stress analysis is a design science as is the subject of heat transfer. When the subject of corrosion is considered in the framework design a clear framework of the priorities and objectives becomes apparent. Further, corrosion becomes a more explicit and important subject in the overall design, manufacturing, and operation phases of equipment: in this framework, the funding and support of corrosion work is necessary to the designers and users of equipment. The subject of corrosion is usually less important in the early stages of operation of equipment: in these early stages, the subjects. Corrosion becomes important to the longer term reliability and safety of equipment. Corrosion is often a principal determiner of design life. Corrosion is often more important after the manufacturing warranty is expired: therefore the subject is often more important to the user than to the manufacturer. In order that the subject of corrosion is considered and incorporated in the design as well as in user specifications, there must be a language and means of easily understood communication between the design-operation community and the corrosion community. For example, the designers do not understand the language of 'pitting potential': rather, they understand design life and permissible stress. Thus, corrosion must be put into terms that can be understood and utilized by designers and operators. Two methodologies have been developed for communicating effectively between the corrosion and the design communities: these are the 'Corrosion Based Design Approach' and the 'Location for Analysis Matrix.' These provide simple check off lists to designers for asking questions and assuring that credible answers have been obtained on issues that affect reliable and economic performance. Both of these subject are discussed in this presentation. The future of corrosion research is its effective linkage with design and operation of

  3. Efecto hipotensor del extracto de ajo (Allium sativum macerado por 18 semanas en un modelo experimental in vivo

    Directory of Open Access Journals (Sweden)

    David Chaupis-Meza

    Full Text Available Objetivos. Determinar si el extracto de ajo (Allium sativum macerado por 18 semanas tiene igual o mejor efecto hipotensor que el captopril en ratas. Materiales y métodos. Se realizó un estudio experimental in vivo con ratas machos Holtzman, clasificados en cinco grupos: 100, 500 y 1000 mg/kg de extracto de ajo, Captopril de 100 mg/kg y un grupo vehículo. El L-NAME (N- -nitro L-arginina-metil-éster administrado vía intraperitoneal 50 mg/kg desde el inicio del experimento, elevó la presión arterial desde el tercer día. El análisis estadístico consistió en las pruebas T de Student para medias pareadas, ANOVA y comparación múltiple de Scheffe. Resultados. El ajo macerado extraído por un proceso hidroalcohólico durante 18 semanas provocó una disminución de la presión arterial en animales de experimentación. El análisis de los tratamientos sobre la presión arterial media (PAM, obtuvieron diferencias significativas desde el tercer día. La comparación sobre la PAM final versus PAM basal (medias no diferentes y el efecto hipotensor (% fueron: ajo-100 (p=0,008, 59,8%; ajo-500 (p=0,021, 80,6%; ajo-1000 (p=0,034, 88,5%, Captopril (p=0,437, 99,9% y vehículo (p=0,001, 0%. Conclusiones. El ajo macerado a un periodo de 18 semanas resultó eficaz para producir un efecto hipotensor en ratas, inducidas a hipertensión arterial por L-NAME

  4. The corrosion behaviour of nanograined metals and alloys

    Directory of Open Access Journals (Sweden)

    Herrasti, P.

    2012-10-01

    Full Text Available There has been considerable interest in the properties of nanocrystalline materials over the last decade. Such materials include metals and alloys with a crystal size within the order of 1 to 100 nm. The interest arises due to the substantial differences in electrical, optical and magnetic properties and also due to their high adsorption capability and chemical reactivity compared to their larger grained counterparts. In this paper, the corrosion of nanocrystalline metals and alloys is investigated and compared to the corrosion of microcrystalline materials having a similar composition. The focus is on the corrosion of nickel, copper, cobalt and iron alloys. Key aspects of different corrosion behaviour such grain boundaries and size are identified.

    En la última década ha habido un gran interes en las propiedades de materiales nanocristalinos. Estos materiales incluyen metales y aleaciones con un tamaño de cristal del orden de 1 a 100 nm. El interes por estos materiales es debido a las grandes diferencias en cuanto a sus propiedades electricas, opticas y magneticas, asi como a su alta capacidad de adsorción y reactividad química en relación a los mismos materiales con tamaños de grano mayores. En este trabajo se ha investigado y comparado la corrosión de materiales nano y microcristalinos de similar composición química. Principalmente se ha centrado en la corrosión de metales tales como niquel, cobre, cobalto y aleaciones de hierro. Se ha comprobado que los diferentes comportamientos frente al proceso de corrosión están intimamente ligados con los bordes de grano y el tamaño de dichos granos.

  5. Corrosion Cost and Corrosion Map of Korea - Based on the Data from 2005 to 2010

    International Nuclear Information System (INIS)

    Kim, Y. S.; Lim, H. K.; Kim, J. J.; Hwang, W. S.; Park, Y. S.

    2011-01-01

    Corrosion of metallic materials occurs by the reaction with corrosive environment such as atmosphere, marine, soil, urban, high temperature etc. In general, reduction of thickness and cracking and degradation are resulted from corrosion. Corrosion in all industrial facilities and infrastructure causes large economic losses as well as a large number of accidents. Economic loss by corrosion has been reported to be nearly 1-6% of GNP or GDP. In order to reduce corrosion damage of industrial facilities, corrosion map as well as a systematic investigation of the loss of corrosion in each industrial sector is needed. The Corrosion Science Society of Korea in collaboration with 15 universities and institutes has started to survey on the cost of corrosion and corrosion map of Korea since 2005. This work presents the results of the survey on cost of corrosion by Uhlig, Hoar, and input-output methods, and the evaluation of atmospheric corrosion rate of carbon steel, weathering steel, galvanized steel, copper, and aluminum in Korea. The total corrosion cost was estimated in terms of the percentage of the GDP of industry sectors and the total GDP of Korea. According to the result of Input/output method, corrosion cost of Korea was calculated as 2.9% to GDP (2005). Time of wetness was shown to be categories 3 to 4 in all exposure areas. A definite seasonal difference was observed in Korea. In summer and fall, time of wetness was higher than in other seasons. Because of short exposure period (12 months), significant corrosion trends depending upon materials and exposure corrosion environments were not revealed even though increased mass loss and decreased corrosion rate by exposure time

  6. Electrochemical characterisation speeds up prediction of corrosion behaviour

    Energy Technology Data Exchange (ETDEWEB)

    Schuring, E.W.; Hooijmans, J.W. [ECN Environment and Energy Engineering, Petten (Netherlands)

    2013-04-15

    The contents of this presentation show the following elements: Introduction; Corrosion in real life; Why Electrochemical characterisation of corrosion; Applications (corrosion resistance coatings, corrosion behaviour (brazed) joints); Available electrochemical corrosion techniques; Standards; Conclusions. In the Conclusions the corrosion screening method is summarized: ECN method fast; within 1h -1 week results depending on test method; Fast pre-selection of promising materials/combinations (cost savings); Determining of corrosion initiation; Determination of corrosion mechanisms and propagation; Life time predictions possible; Strong combination with metallographic post-investigation; Ranking materials / constructions for corrosion performance.

  7. Corrosion strength monitoring of NPP component residual lifetime

    International Nuclear Information System (INIS)

    Denisov, V.G.; Belous, V.N.; Arzhaev, A.I.; Shuvalov, V.A.

    1994-01-01

    Importance of corrosion and fatigue monitoring; types of corrosion determine the NPP equipment life; why automated on-line corrosion and fatigue monitoring is preferable; major stages of lifetime monitoring system development; major groups of sensors for corrosion and strength monitoring system; high temperature on-line monitoring of water chemistry and corrosion; the RBMK-1000 NPP unit automatic water chemistry and corrosion monitoring scheme; examples of pitting, crevice and general corrosion forecast calculations on the basis of corrosion monitoring data; scheme of an experimental facility for water chemistry and corrosion monitoring sensor testing. 2 figs., 4 tabs

  8. Microencapsulation Technology for Corrosion Mitigation by Smart Coatings

    Science.gov (United States)

    Buhrow, Jerry; Li, Wenyan; Jolley, Scott; Calle, Luz M.

    2011-01-01

    A multifunctional, smart coating for the autonomous control of corrosion is being developed based on micro-encapsulation technology. Corrosion indicators as well as corrosion inhibitors have been incorporated into microcapsules, blended into several paint systems, and tested for corrosion detection and protection effectiveness. This paper summarizes the development, optimization, and testing of microcapsules specifically designed to be incorporated into a smart coating that will deliver corrosion inhibitors to mitigate corrosion autonomously. Key words: smart coating, corrosion inhibition, microencapsulation, microcapsule, pH sensitive microcapsule, corrosion inhibitor, corrosion protection pain

  9. Sepsis por shigella flexneri

    Directory of Open Access Journals (Sweden)

    César Cabrera C

    2005-04-01

    Full Text Available Se presenta un caso raro de sepsis por Shigella flexneri en una paciente de 45 años de edad quien estando hospitalizada para el estudio de un tumor cerebral, requirió el uso de manitol y dosis altas de corticoides; luego de ello presenta deposiciones líquidas con moco y sangre, desarrolla síndrome de respuesta inflamatoria sistémica, luego se aísla Shigella flexneri en el hemocultivo; recibió tratamiento antibiótico con ciprofloxacina. Se describen las características del caso y se comenta de acuerdo con la revisión de literatura.

  10. Corrosion characteristics of K-claddings

    International Nuclear Information System (INIS)

    Park, J. Y.; Choi, B. K.; Jung, Y. H.; Jung, Y. H.

    2004-01-01

    The Improvement of the corrosion resistance of nuclear fuel claddings is the critical issue for the successful development of the high burn-up fuel. KAERI have developed the K-claddings having a superior corrosion resistance by controlling the alloying element addition and optimizing the manufacturing process. The comparative evaluation of the corrosion resistance for K-claddings and the foreign claddings was performed and the effect of the heat treatment on the corrosion behavior of K-claddings was also examined. Corrosion tests were carried out in the conditions of 360 .deg. C pure water, PWR-simulating loop and 400 .deg. C steam, From the results of the corrosion tests, it was found that the corrosion resistance of K-claddings is superior to those of Zry4 and A claddings and K6 showed a better corrosion resistance than K3. The corrosion behavior of K-cladding was strongly influenced by the final annealing rather than the intermediate annealing, and the corrosion resistance increased with decreasing the final annealing temperature

  11. Current status of studies on nodular corrosion

    International Nuclear Information System (INIS)

    Yasuda, Takayoshi; Kawasaki, Satoru; Echigoya, Hironori; Kinoshita, Yutaka; Kubota, Hiroyuki; Konishi, Takao; Yamanaka, Tuneyasu.

    1993-01-01

    The studies on nodular corrosion formed on the outer surface of BWR fuel cladding tubes were reviewed. Main factors affecting the corrosion behavior were material and environmental conditions and combined effect. The effects of such material conditions as fabrication process, alloy elements, texture and surface treatment and environmental factors as neutron irradiation, thermo-hydrodynamic, water chemistry, purity of the coolant and contact with foreign metals on the corrosion phenomena were surveyed. Out-of-reactor corrosion test methods and models for the corrosion mechanism were also reviewed. Suppression of the accumulated annealing temperature during tube reduction process improved the nodular corrosion resistance of Zircaloys. Improved resistance for the nodular corrosion was reported for the unirradiated Zircaloys with some additives. Detailed irradiation test under the BWR conditions is needed to confirm the trend. Concerning the environmental factors, boiling on the cladding surface due to heat flux reduces the nodular corrosion susceptibility, while oxidizing radical generated from dissolved oxygen accelerates the corrosion. Concerning corrosion mechanisms, importance of such phenomena as the depleted zone of alloying elements in zirconium matrix, reduction of H + to H 2 in oxide layer, electrochemical property of precipitates, crystallographic anisotropy of oxidation rates were revealed. (author) 59 refs

  12. Protecting solar collector systems from corrosion

    Energy Technology Data Exchange (ETDEWEB)

    1978-01-01

    The main cause of the reduced life of a solar heating system is corrosion of the exterior parts and the internal components. This report outlines ways of reducing the cost of solar heating by reducing the corrosion in solar heating systems, and hence increasing the system's service life. Mechanisms for corrosion are discussed: these include galvanic corrosion and crevice corrosion. Means of minimizing corrosion at the design stage are then described. Such methods, when designing the solar collector, involve ensuring proper drainage of exterior water; eliminating situations where moisture, dirt and pollutants may collect; preventing condensation inside the collector; using proper gaskets and sealants at appropriate places; and selecting optimum materials and coatings. Interior corrosion can be minimized at the design stage by choosing a good heat transfer fluid and corrosion inhibitor, in the case of systems where liquids are used; ensuring a low enough flow rate to avoid erosion; designing the system to avoid crevices; and avoiding situations where galvanic corrosion could occur. Other procedures are given for minimizing corrosion in the construction and operation of solar heating systems. 7 figs., 7 tabs.

  13. Portable exhausters POR-004 SKID B, POR-005 SKID C, POR-006 SKID D storage plan

    International Nuclear Information System (INIS)

    Nelson, O.D.; Keller, G.M.

    1997-01-01

    This document provides a storage plan for portable exhausters POR-004 SKID B, POR-005 SKID C, AND POR-006 SKID D. The exhausters will be stored until they are needed by the TWRS (Tank Waste Remediation Systems) Saltwell Pumping Program. The storage plan provides criteria for portable exhauster storage, periodic inspections during storage, and retrieval from storage

  14. Corrosion and protection of magnesium alloys

    Energy Technology Data Exchange (ETDEWEB)

    Ghali, E. [Laval Univ., Quebec City, PQ (Canada). Dept. of Mining and Metallurgy

    2000-07-01

    The oxide film on magnesium offers considerable surface protection in rural and some industrial environments and the corrosion rate lies between that of aluminum and low carbon steels. Galvanic coupling of magnesium alloys, high impurity content such as Ni, Fe, Cu and surface contamination are detrimental for corrosion resistance of magnesium alloys. Alloying elements can form secondary particles which are noble to the Mg matrix, thereby facilitating corrosion, or enrich the corrosion product thereby possibly inhibiting the corrosion rate. Bimetallic corrosion resistance can be increased by fluxless melt protection, choice of compatible alloys, insulating materials, and new high-purity alloys. Magnesium is relatively insensible to oxygen concentration. Pitting, corrosion in the crevices, filiform corrosion are observed. Granular corrosion of magnesium alloys is possible due to the cathodic grain-boundary constituent. More homogeneous microstructures tend to improve corrosion resistance. Under fatigue loading conditions, microcrack initiation in Mg alloys is related to slip in preferentially oriented grains. Coating that exclude the corrosive environments can provide the primary defense against corrosion fatigue. Magnesium alloys that contain neither aluminum nor zinc are the most SCC resistant. Compressive surface residual stresses as that created by short peening increase SCC resistance. Cathodic polarization or cladding with a SCC resistant sheet alloy are good alternatives. Effective corrosion prevention for magnesium alloy components and assemblies should start at the design stage. Selective surface preparation, chemical treatment and coatings are recommended. Oil application, wax coating, anodizing, electroplating, and painting are possible alternatives. Recently, it is found that a magnesium hydride layer, created on the magnesium surface by cathodic charging in aqueous solution is a good base for painting. (orig.)

  15. Degradation of aged plants by corrosion: 'Long cell action' in unresolved corrosion issues

    International Nuclear Information System (INIS)

    Saji, Genn

    2009-01-01

    In a series of previously published papers the author has identified that 'long cell action' corrosion plays a pivotal role in practically all unresolved corrosion issues for all types of nuclear power plants (e.g. PWR/VVER, BWR/RBMK and CANDU). Some of these unresolved issues are IGSCC, PWSCC, AOA and FAC (erosion-corrosion). In conventional corrosion science it is well established that 'long cell action' can seriously accelerate or suppress the local cell corrosion activities. Although long cell action is another fundamental mechanism of corrosion, especially in a 'soil corrosion' arena, potential involvement of this corrosion process has never been studied in nuclear and fossil power plants as far as the author has been able to establish. The author believes that the omission of this basic corrosion mechanism is the root cause of practically all un-resolved corrosion issues. In this paper, the author further elaborated on his assessment to other key corrosion issues, e.g. steam generator and turbine corrosion issues, while briefly summarizing previous discussions for completeness purposes, as well as introducing additional experimental and theoretical evidence of this basic corrosion mechanism. Due to the importance of this potential mechanism the author is calling for institutional review activities and further verification experiments in the form of a joint international project.

  16. 49 CFR 192.477 - Internal corrosion control: Monitoring.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Internal corrosion control: Monitoring. 192.477... Control § 192.477 Internal corrosion control: Monitoring. If corrosive gas is being transported, coupons... internal corrosion. Each coupon or other means of monitoring internal corrosion must be checked two times...

  17. Nefropatía por contraste en el síndrome coronario agudo

    Directory of Open Access Journals (Sweden)

    Mariana Carnevalini

    2011-10-01

    Full Text Available La nefropatía inducida por contraste (NIC es una de las causas más frecuentes de insuficiencia renal en pacientes internados. En el síndrome coronario agudo (SCA, la presencia de NIC aumenta la morbimortalidad. Las medidas de profilaxis y los factores de riesgo intervinientes de NIC en SCA no han sido determinados con exactitud. El objetivo de este estudio fue evaluar la incidencia de NIC y los factores asociados a su desarrollo en pacientes ingresados en unidad coronaria con requerimiento de cinecoronariografía (CCG. Se realizó un estudio de cohorte retrospectivo. Se incluyeron pacientes consecutivos cursando SCA estudiados con CCG dentro de las 72 horas de su admisión. Se definió NIC al aumento del 25% del valor de creatinina a las 48 h sobre el nivel basal de ingreso. El período de inclusión fue entre el 1° de enero de 2004 hasta el 30 de junio de 2010. Se analizaron 125 casos. La incidencia de NIC fue del 10.4% (n = 13. En el análisis multivariado, los factores asociados independientemente a su desarrollo fueron la edad [OR 1.05 (IC 95% 1.004 - 1.11 p = 0.034], la angioplastia a múltiple vaso [OR 2.2 (IC 95% 1.07 - 4.8, p = 0.03] y el volumen de contraste utilizado [OR 1.007 (IC 95% 1.001 - 1.01, p = 0.014].

  18. Nuclear waste glass corrosion mechanisms

    International Nuclear Information System (INIS)

    Jantzen, C.M.

    1987-04-01

    Dissolution of nuclear waste glass occurs by corrosion mechanisms similar to those of other solids, e.g., metallurgical and mineralogic systems. Metallurgical phenomena such as active corrosion, passivation and immunity have been observed to be a function of the glass composition and the solution pH. Hydration thermodynamics was used to quantify the role of glass composition and its effect on the solution pH during dissolution. A wide compositional range of natural, lunar, medieval, and nuclear waste glasses, as well as some glass-ceramics were investigated. The factors observed to affect dissolution in deionized water are pertinent to the dissolution of glass in natural environments such as the groundwaters anticipated to interact with nuclear waste glass in a geologic repository. The effects of imposed pH and oxidation potential (Eh) conditions existing in natural environments on glass dissolution is described in the context of Pourbaix diagrams, pH potential diagrams, for glass

  19. Mechanisms of metal dusting corrosion

    DEFF Research Database (Denmark)

    Hummelshøj, Thomas Strabo

    In this thesis the early stages of metal dusting corrosion is addressed; the development of carbon expanded austenite, C, and the decomposition hereof into carbides. Later stages of metal dusting corrosion are explored by a systematic study of stainless steel foils exposed to metal dusting...... deformed stainless steel flakes is transformed to expanded martensite/austenite during low-temperature carburization. Various experimental procedures to experimentally determine the concentration dependent diffusion coefficient of carbon in expanded austenite are evaluated. The most promising procedure...... powders and flakes. The nature of the decomposition products, carbides of the form M23C6 and M7C3, were evaluated by X-ray diffraction, light optical microscopy, scanning electron microscopy and thermodynamic modelling. The decomposition was found to be dependent on several parameters such as thermal...

  20. Corrosion of carbon steel welds

    International Nuclear Information System (INIS)

    Daniel, B.

    1988-09-01

    This report assesses the factors which cause preferential attack to occur in carbon steel fusion welds. It was concluded that the main factors were: the inclusion content of the weld metal, the potential of the weld metal being less noble than that of the parent, and the presence of low-temperature transformation products in the heat-affected zone of the weld. These factors should be minimized or eliminated as appropriate so that the corrosion allowances determined for carbon steel waste drums is also adequate for the welds. An experimental/theoretical approach is recommended to evaluate the relative corrosion resistance of welds prepared from BS 4360 grade 43A steel to that of the parent material. (author)

  1. Tri-Service Corrosion Conference

    Science.gov (United States)

    2002-01-18

    Video- Thermographie. M.S. Thesis, University Magdeburg , Germany 5. N. Meyendorf et al. (2001) Early Detection of Corrosion in Aircraft Structures...We serve as a bridge between developers and users, helping transition technologies into operational use. For more information, contact: Major...scrapers, tractors, fork lifts and material trucks. • Engineer-Trlr - trailered engineering equipment including, fixed bridge , fuel pump module, water

  2. Stress Corrosion of Ceramic Materials.

    Science.gov (United States)

    1986-08-01

    rupture directly, or are hydrolyzed by the water in the environment. This type of reaction is known to be important to the corrosion of glass in basic...covered .ith silanol groups so that the surface is virtually uncharged. As the pH is increased, the surface gradually hydrolyzes forming silanolate...is plotted assuming a decay distance of 0.3 nm. The data on lecithin is obtained by a non-fracture technique in which the layer spacing is determined

  3. Corrosion and Corrosion Fatigue of Aluminum Alloys: Chemistry, Micromechanics and Reliability

    National Research Council Canada - National Science Library

    Wei, Robert

    1998-01-01

    ... No. F49620-98-1-0198, to further develop a basic mechanistic understanding of the damage evolution processes of localized corrosion and corrosion fatigue crack nucleation and growth in aluminum alloys...

  4. Chemical cleaning, decontamination and corrosion

    International Nuclear Information System (INIS)

    Gadiyar, H.S.; Das Chintamani; Gaonkar, K.B.

    1991-01-01

    Chemical cleaning of process equipments and pipings in chemical/petrochemical industries is necessitated for improving operation, for preventing premature failures and for avoiding contamination. In developing a chemical formulation for cleaning equipments, the important aspects to be considered include (i) effective removal of corrosion products and scales, (ii) minimum corrosion of the base metal, (iii) easy to handle chemicals and (iv) economic viability. As on date, a wide variety of chemical formulations are available, many of them are either proprietory or patented. For evolving an effective formulation, knowledge of the oxides of various metals and alloys on the one hand and acid concentration, complexing agents and inhibitors to be incorporated on the other, is quite essential. Organic acids like citric acid, acetic acid and formic acid are more popular ones, often used with EDTA for effective removal of corrosion products from ferrous components. The report enumerates some of the concepts in developing effective formulations for chemical cleaning of carbon steel components and further, makes an attempt to suggest simple formulations to be developed for chemical decontamination. (author). 6 refs., 3 fi gs., 4 tabs

  5. Galvanic corrosion of beryllium welds

    International Nuclear Information System (INIS)

    Hill, M.A.; Butt, D.P.; Lillard, R.S.

    1997-01-01

    Beryllium is difficult to weld because it is highly susceptible to cracking. The most commonly used filler metal in beryllium welds is Al-12 wt.% Si. Beryllium has been successfully welded using Al-Si filler metal with more than 30 wt.% Al. This filler creates an aluminum-rich fusion zone with a low melting point that tends to backfill cracks. Drawbacks to adding a filler metal include a reduction in service temperature, a lowering of the tensile strength of the weld, and the possibility for galvanic corrosion to occur at the weld. To evaluate the degree of interaction between Be and Al-Si in an actual weld, sections from a mock beryllium weldment were exposed to 0.1 M Cl - solution. Results indicate that the galvanic couple between Be and the Al-Si weld material results in the cathodic protection of the weld and of the anodic dissolution of the bulk Be material. While the cathodic protection of Al is generally inefficient, the high anodic dissolution rate of the bulk Be during pitting corrosion combined with the insulating properties of the Be oxide afford some protection of the Al-Si weld material. Although dissolution of the Be precipitate in the weld material does occur, no corrosion of the Al-Si matrix was observed

  6. Metal corrosion inhibitors and ecology

    International Nuclear Information System (INIS)

    Krasts, H.; Svarce, J.; Berge, B.

    1999-01-01

    The use of metal corrosion inhibitors in water is one of the cheapest method to protect metals against corrosion. However, the used inhibitors can come to surface water in the course of time and can become as source of environmental pollution. It is important to co-ordinate amount of substances in the elaborated inhibitors not only with demands for metal protection, but also with demands for quality of surface water and drinking water according to normative statements: 3.5 mg/l (as PO 4 ) for hexametaphosphate, tripolyphosphate and phosphonate; 40 mg/l (as SiO 2 for silicate, up to 1 mg/l for CU 2+ ; up to 5 mg/l for Zn 2+ ; up to 1 mg/l for B; up to 0.5 mg/l for Mo 2+ . The examples of the elaborated inhibitors are given. Many organic substances can be used as corrosion inhibitors, but there is shortage of standard methods for their analysis in water in Latvia. Removing of salt's deposits from boilers needs elaboration of a separate normative statement for dispersing waste water which content chloride at high concentration and heavy metals. (authors)

  7. Aluminum corrosion product release kinetics

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, Matt, E-mail: Matthew.Edwards@cnl.ca; Semmler, Jaleh; Guzonas, Dave; Chen, Hui Qun; Toor, Arshad; Hoendermis, Seanna

    2015-07-15

    Highlights: • Release of Al corrosion product was measured in simulated post-LOCA sump solutions. • Increased boron was found to enhance Al release kinetics at similar pH. • Models of Al release as functions of time, temperature, and pH were developed. - Abstract: The kinetics of aluminum corrosion product release was examined in solutions representative of post-LOCA sump water for both pressurized water and pressurized heavy-water reactors. Coupons of AA 6061 T6 were exposed to solutions in the pH 7–11 range at 40, 60, 90 and 130 °C. Solution samples were analyzed by inductively coupled plasma atomic emission spectroscopy, and coupon samples were analyzed by secondary ion mass spectrometry. The results show a distinct “boron effect” on the release kinetics, expected to be caused by an increase in the solubility of the aluminum corrosion products. New models were developed to describe both sets of data as functions of temperature, time, and pH (where applicable)

  8. Corrosion of steel in concrete

    International Nuclear Information System (INIS)

    Preece, C.M.

    1982-10-01

    A comparative study has been made of those properties of Massiv and Standard cements which are considered to determine their ability to protect steel reinforcement from corroding. Saturated Massiv cement has a higher evaporabel water content, but a significantly finer pore structure than has saturated Standard cement. This fine structure resulted in an electrical resistivity ten times higher and chloride diffusivity ten times lower than those of Standard cement. Electrochemical measurements have shown that the passive current density of steel in Massiv mortar is higher than that of steel in Standard mortar, but the higher current should lead to a more rapid decrease in potential to a level at which neither chloride attack of hydrogen evolution will occur. Whereas steel in Standard mortar was found to be highly susceptible to crevice corrosion, no such attack has been observed in Massiv mortar. Moreover, the initiation of chloride induced corrosion and the subsequent rates of corrosion were both lower in Massiv mortar than in Standard mortar. Thus, it may be predicted that Massiv cement would provide greater protection for steel reinforcement in underground structures exposed to chloride containing ground water than would Standard cement. (author)

  9. Evaluation of corrosion attack of chimney liners

    Directory of Open Access Journals (Sweden)

    Blahetová M.

    2016-06-01

    Full Text Available The case study of chimney liner corrosion addresses three specific cases of damage of chimney systems from of stainless steels. These systems were used for flue of gas arising from the combustion of brown coal in small automatic boilers, which are used for heating. Detailed analyzes implied that the cause of devastating corrosion of the steel AISI 316 and 304 steel (CSN 17349, 17241 was particularly high content of halides (chlorides and fluorides, which caused a severe pitting corrosion, which led up to the perforation of the liner material. Simultaneous reduction of the thickness of the used sheets was due to by the general corrosion, which was caused by the sulfur in the solid fuel. The condensation then led to acid environment and therefore the corrosion below the dew point of the sulfuric acid has occurred. All is documented by metallographic analysis and microanalysis of the corrosion products.

  10. Electrochemical corrosion testing of metal waste forms

    International Nuclear Information System (INIS)

    Abraham, D. P.; Peterson, J. J.; Katyal, H. K.; Keiser, D. D.; Hilton, B. A.

    1999-01-01

    Electrochemical corrosion tests have been conducted on simulated stainless steel-zirconium (SS-Zr) metal waste form (MWF) samples. The uniform aqueous corrosion behavior of the samples in various test solutions was measured by the polarization resistance technique. The data show that the MWF corrosion rates are very low in groundwaters representative of the proposed Yucca Mountain repository. Galvanic corrosion measurements were also conducted on MWF samples that were coupled to an alloy that has been proposed for the inner lining of the high-level nuclear waste container. The experiments show that the steady-state galvanic corrosion currents are small. Galvanic corrosion will, hence, not be an important mechanism of radionuclide release from the MWF alloys

  11. Corrosion monitoring during a chemical cleaning

    International Nuclear Information System (INIS)

    Delepine, J.; Feron, D.; Roy, M.

    1994-01-01

    In order to estimate the possible corrosion induced by the chemical cleaning, a corrosion monitoring has been realized during the cleaning of the secondary circuit (including the model boiler) of ORION loop. It included coupons and electrodes and has required a preliminary setting in laboratory. The electrochemical device which was used during the chemical cleaning included two reference electrodes (Ag/AgCl) and eight metallic electrodes (carbon steel, stainless steel, Alloy 600 and Alloy 690) for free corrosion potential monitoring, three other carbon steel electrodes for instantaneous corrosion rate measurements by polarization resistance and three coupling devices with different surface ratios between carbon steel and Alloy 600. The results showed a good agreement between corrosion rates measured by weight losses on coupons or by electrochemistry (polarization resistance), and an increase of the carbon steel corrosion rate when it was coupled with Alloy 600. (authors). 5 figs., 2 tabs., 3 refs

  12. Corrosion-Activated Micro-Containers for Environmentally Friendly Corrosion Protective Coatings

    Science.gov (United States)

    Li, Wenyan; Buhrow, J. W.; Zhang, X.; Johnsey, M. N.; Pearman, B. P.; Jolley, S. T.; Calle, L. M.

    2016-01-01

    This work concerns the development of environmentally friendly encapsulation technology, specifically designed to incorporate corrosion indicators, inhibitors, and self-healing agents into a coating, in such a way that the delivery of the indicators and inhibitors is triggered by the corrosion process, and the delivery of self-healing agents is triggered by mechanical damage to the coating. Encapsulation of the active corrosion control ingredients allows the incorporation of desired autonomous corrosion control functions such as: early corrosion detection, hidden corrosion detection, corrosion inhibition, and self-healing of mechanical damage into a coating. The technology offers the versatility needed to include one or several corrosion control functions into the same coating.The development of the encapsulation technology has progressed from the initial proof-of-concept work, in which a corrosion indicator was encapsulated into an oil-core (hydrophobic) microcapsule and shown to be delivered autonomously, under simulated corrosion conditions, to a sophisticated portfolio of micro carriers (organic, inorganic, and hybrid) that can be used to deliver a wide range of active corrosion ingredients at a rate that can be adjusted to offer immediate as well as long-term corrosion control. The micro carriers have been incorporated into different coating formulas to test and optimize the autonomous corrosion detection, inhibition, and self-healing functions of the coatings. This paper provides an overview of progress made to date and highlights recent technical developments, such as improved corrosion detection sensitivity, inhibitor test results in various types of coatings, and highly effective self-healing coatings based on green chemistry. The NASA Kennedy Space Centers Corrosion Technology Lab at the Kennedy Space Center in Florida, U.S.A. has been developing multifunctional smart coatings based on the microencapsulation of environmentally friendly corrosion

  13. Control Multivariable por Desacoplo

    Directory of Open Access Journals (Sweden)

    Fernando Morilla

    2013-01-01

    Full Text Available Resumen: La interacción entre variables es una característica inherente de los procesos multivariables, que dificulta su operación y el diseño de sus sistemas de control. Bajo el paradigma de Control por desacoplo se agrupan un conjunto de metodologías, que tradicionalmente han estado orientadas a eliminar o reducir la interacción, y que recientemente algunos investigadores han reorientado con objetivos de solucionar un problema tan complejo como es el control multivariable. Parte del material descrito en este artículo es bien conocido en el campo del control de procesos, pero la mayor parte de él son resultados de varios años de investigación de los autores en los que han primado la generalización del problema, la búsqueda de soluciones de fácil implementación y la combinación de bloques elementales de control PID. Esta conjunción de intereses provoca que no siempre se pueda conseguir un desacoplo perfecto, pero que sí se pueda conseguir una considerable reducción de la interacción en el nivel básico de la pirámide de control, en beneficio de otros sistemas de control que ocupan niveles jerárquicos superiores. El artículo resume todos los aspectos básicos del Control por desacoplo y su aplicación a dos procesos representativos: una planta experimental de cuatro tanques acoplados y un modelo 4×4 de un sistema experimental de calefacción, ventilación y aire acondicionado. Abstract: The interaction between variables is inherent in multivariable processes and this fact may complicate their operation and control system design. Under the paradigm of decoupling control, several methodologies that traditionally have been addressed to cancel or reduce the interactions are gathered. Recently, this approach has been reoriented by several researchers with the aim to solve such a complex problem as the multivariable control. Parts of the material in this work are well known in the process control field; however, most of them are

  14. Corrosion Properties of Laser Welded Stainless Steel

    DEFF Research Database (Denmark)

    Weldingh, Jakob; Olsen, Flemmming Ove

    1997-01-01

    In this paper the corrosion properties of laser welded AISI 316L stainless steel are examined. A number of different welds has been performed to test the influence of the weld parameters of the resulting corrosion properties. It has been chosen to use the potential independent critical pitting...... temperature (CPT) test as corrosion test. The following welding parameters are varied: Welding speed, lsser power, focus point position and laser operation mode (CW or pulsed)....

  15. Natural analogues of nuclear waste glass corrosion

    International Nuclear Information System (INIS)

    Abrajano, T.A. Jr.; Ebert, W.L.; Luo, J.S.

    1999-01-01

    This report reviews and summarizes studies performed to characterize the products and processes involved in the corrosion of natural glasses. Studies are also reviewed and evaluated on how well the corrosion of natural glasses in natural environments serves as an analogue for the corrosion of high-level radioactive waste glasses in an engineered geologic disposal system. A wide range of natural and experimental corrosion studies has been performed on three major groups of natural glasses: tektite, obsidian, and basalt. Studies of the corrosion of natural glass attempt to characterize both the nature of alteration products and the reaction kinetics. Information available on natural glass was then compared to corresponding information on the corrosion of nuclear waste glasses, specifically to resolve two key questions: (1) whether one or more natural glasses behave similarly to nuclear waste glasses in laboratory tests, and (2) how these similarities can be used to support projections of the long-term corrosion of nuclear waste glasses. The corrosion behavior of basaltic glasses was most similar to that of nuclear waste glasses, but the corrosion of tektite and obsidian glasses involves certain processes that also occur during the corrosion of nuclear waste glasses. The reactions and processes that control basalt glass dissolution are similar to those that are important in nuclear waste glass dissolution. The key reaction of the overall corrosion mechanism is network hydrolysis, which eventually breaks down the glass network structure that remains after the initial ion-exchange and diffusion processes. This review also highlights some unresolved issues related to the application of an analogue approach to predicting long-term behavior of nuclear waste glass corrosion, such as discrepancies between experimental and field-based estimates of kinetic parameters for basaltic glasses

  16. Internal corrosion control of northern pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Papavinasam, S.

    2005-02-01

    The general causes of internal corrosion in pipelines were discussed along with the methods to control them. Efficient methods are needed to determine chemical efficiency for mitigating internal corrosion in transmission pipelines, particularly those used in environmentally sensitive regions in the Arctic where harsh environmental conditions prevail. According to the Office of Pipeline Safety, 15 per cent of pipeline failures in the United States from 1994 to 2000 were caused by internal corrosion. Since pipelines in the United States are slightly older than Canadian pipelines, internal corrosion is a significant issue from a Canadian perspective. There are 306,618 km of energy-related pipelines in western Canada. Between April 2001 and March 2002 there were 808 failures, of which 425 failures resulted from internal corrosion. The approach to control internal corrosion comprises of dehydrating the gases at production facilities; controlling the quality of corrosive gases such as carbon dioxide and hydrogen sulphide; and, using internal coatings. The approaches to control internal corrosion are appropriate, when supplemented by adequate integrity management program to ensure that corrosive liquids do not collect, over the operational lifetime of the pipelines, at localized areas. It was suggested that modeling of pipeline operations may need improvement. This paper described the causes, prediction and control of internal pitting corrosion. It was concluded that carbon steel equipment can continue to be used reliably and safely as pipeline materials for northern pipelines if the causes that lead to internal corrosion are scientifically and accurately predicted, and if corrosion inhibitors are properly evaluated and applied. 5 figs.

  17. Anodizing of aluminum with improved corrosion properties

    International Nuclear Information System (INIS)

    John, P.; Khan, I.U.

    2010-01-01

    Anodizing of aluminum was studied in sulphuric/oxalic/boric acid electroiyte system. The corrosion resistance of the anodic oxide coating of aluminum was determined by potentiodynamic polarization test and scanning electron microscope (SEM) was used to investigate the surface morphology before and after corrosion test. It was found that the oxide coating obtained by this method showed better corrosion resistance with no significant difference in surface morphology. (author)

  18. Preventing Corrosion by Controlling Cathodic Reaction Kinetics

    Science.gov (United States)

    2016-03-25

    3. DATES COVERED (From - To) 09/23/15 - 04/22/16 4. TITLE AND SUBTITLE Sa. CONTRACT NUMBER Preventing Corrosion by Controlling Cathodic Reaction...Preventing corrosion by controlling cathodic reaction kinetics Progress Report for Period: 1 SEP 2015-31 MAR 2016 John Keith Department of...25 March 2016 Preventing corrosion by controlling cathodic reaction kinetics Annual Summary Report: FY16 PI: John Keith, 412-624-7016,jakeith

  19. Recognition and Analysis of Corrosion Failure Mechanisms

    OpenAIRE

    Steven Suess

    2006-01-01

    Corrosion has a vast impact on the global and domestic economy, and currently incurs losses of nearly $300 billion annually to the U.S. economy alone. Because of the huge impact of corrosion, it is imperative to have a systematic approach to recognizing and mitigating corrosion problems as soon as possible after they become apparent. A proper failure analysis includes collection of pertinent background data and service history, followed by visual inspection, photographic documentation, materi...

  20. The oxidation and corrosion of ODS alloys

    Science.gov (United States)

    Lowell, Carl E.; Barrett, Charles A.

    1990-01-01

    The oxidation and hot corrosion of high temperature oxide dispersion strengthened (ODS) alloys are reviewed. The environmental resistance of such alloys are classified by oxide growth rate, oxide volatility, oxide spalling, and hot corrosion limitations. Also discussed are environmentally resistant coatings for ODS materials. It is concluded that ODS NiCrAl and FeCrAl alloys are highly oxidation and corrosion resistant and can probably be used uncoated.

  1. Oxidation And Hot Corrosion Of ODS Alloy

    Science.gov (United States)

    Lowell, Carl E.; Barrett, Charles A.

    1993-01-01

    Report reviews oxidation and hot corrosion of oxide-dispersion-strengthened (ODS) alloys, intended for use at high temperatures. Classifies environmental resistances of such alloys by rates of growth of oxides, volatilities of oxides, spalling of oxides, and limitations imposed by hot corrosion. Also discusses environmentally resistant coatings for ODS materials. Concludes ODS NICrAl and FeCrAl alloys highly resistant to oxidation and corrosion and can be used uncoated.

  2. Ferritic stainless steels: corrosion resistance + economy

    International Nuclear Information System (INIS)

    Remus, A.L.

    1976-01-01

    Ferritic stainless steels provide corrosion resistance at lower cost. They include Type 409, Type 439, 18SR, 20-Mo (1.6 Mo), 18-2 (2 Mo), 26-1S, E-Brite 26-1, 29 Cr-4 Mo, and 29 Cr-4 Mo-2 Ni. Their corrosion and mechanical properties are examined. Resistance to stress-corrosion cracking is an advantage compared to austenitic types

  3. Natural analogues of nuclear waste glass corrosion.

    Energy Technology Data Exchange (ETDEWEB)

    Abrajano, T.A. Jr.; Ebert, W.L.; Luo, J.S.

    1999-01-06

    This report reviews and summarizes studies performed to characterize the products and processes involved in the corrosion of natural glasses. Studies are also reviewed and evaluated on how well the corrosion of natural glasses in natural environments serves as an analogue for the corrosion of high-level radioactive waste glasses in an engineered geologic disposal system. A wide range of natural and experimental corrosion studies has been performed on three major groups of natural glasses: tektite, obsidian, and basalt. Studies of the corrosion of natural glass attempt to characterize both the nature of alteration products and the reaction kinetics. Information available on natural glass was then compared to corresponding information on the corrosion of nuclear waste glasses, specifically to resolve two key questions: (1) whether one or more natural glasses behave similarly to nuclear waste glasses in laboratory tests, and (2) how these similarities can be used to support projections of the long-term corrosion of nuclear waste glasses. The corrosion behavior of basaltic glasses was most similar to that of nuclear waste glasses, but the corrosion of tektite and obsidian glasses involves certain processes that also occur during the corrosion of nuclear waste glasses. The reactions and processes that control basalt glass dissolution are similar to those that are important in nuclear waste glass dissolution. The key reaction of the overall corrosion mechanism is network hydrolysis, which eventually breaks down the glass network structure that remains after the initial ion-exchange and diffusion processes. This review also highlights some unresolved issues related to the application of an analogue approach to predicting long-term behavior of nuclear waste glass corrosion, such as discrepancies between experimental and field-based estimates of kinetic parameters for basaltic glasses.

  4. Optimising corrosion monitoring in district heating systems

    DEFF Research Database (Denmark)

    Hilbert, Lisbeth Rischel; Thorarinsdottir, R.I.; Andersen, A.

    2002-01-01

    A three-year project - financially supported by the Nordic Industrial Fund - on monitoring of corrosion in district heating systems has been initiated with participation of researchers and industrial partners in Denmark, Finland, Iceland, Norway and Sweden. The primary objective of the project...... is to improve the quality control in district heating systems by corrosion monitoring. In Danish systems electrochemical impedance spectroscopy (EIS), linear polarisation resistance (LPR), high-sensitive electrical resistance (ER) technology, crevice corrosion probes, as well as weight loss coupons...

  5. Corrosion of high temperature resisting alloys exposed to heavy fuel ash; Corrosion de aleaciones resistentes a altas temperaturas expuestas a ceniza de combustoleo pesado

    Energy Technology Data Exchange (ETDEWEB)

    Wong Moreno, Adriana del Carmen

    1998-03-01

    content of vanadium and very low content of sulfur at temperatures near the point of fusion of he vanadium compounds that constitute them. The development of the processes of metallic deterioration that are included in the proposed model was documented through this investigation, for an alloy range, from low alloy steels to nickel based super alloys, as well as for a series of ash deposits whose composition covers a part of the spectra of combinations of sodium/sulfate vanadates that little has been explored. Among the more relevant aspects that were documented and included in the proposed global mechanism, stand out the following ones: The global mechanism of corrosion by ashes of heavy fuel oil based on 3 primary processes of alloy degradation is described: metallic dissolution, accelerated oxidation and sulfidazation. The influence that the temperature and the composition of the ash on the predominance of one or another degradation mechanism has. It is also analyzed how the transformation of the underlying zone to the metal/deposit interphase by diffusion processes and precipitation accelerates the kinetics of degradation of the alloy, particularly, it has been considered the change in the concentrations of Cr, Al and Si, and the sulfide precipitation. Finally, the results obtained contribute in addition with practical information on the alloy performance, which allows to establish an order of merit among the evaluated alloys as far as its resistance to the corrosion, and on the roll of the main alloyings in its behavior of corrosion by fuel oil ash deposits. [Espanol] El objetivo de la investigacion realizada fue estudiar el proceso de degradacion por corrosion a alta temperatura de aleaciones expuestas a cenizas de combustoleo pesado a traves de una evaluacion experimental comparativa de su desempeno que permitio establecer los mecanismos involucrados en el fenomeno. La experimentacion llevada a cabo involucro la determinacion de la resistencia a la corrosion de 14

  6. Colorimetric visualization of tin corrosion: A method for early stage corrosion detection on printed circuit boards

    DEFF Research Database (Denmark)

    Verdingovas, Vadimas; Jellesen, Morten Stendahl; Ambat, Rajan

    2017-01-01

    A majority of printed circuit board surfaces are covered with tin, therefore tin corrosion under humid conditions and movement of tin ions under the influence of an electric field plays an important role in the corrosion failure development. Tracking tin corrosion products spread on the printed c...

  7. Corrosion problems of PWR steam generators

    International Nuclear Information System (INIS)

    Urbancik, L.; Kostal, M.

    Literature data are assessed on corrosion failures of steam generator tubes made of INCONEL 600 or INCOLOY 800. It was found that both alloys with high nickel content showed good stability in a corrosion environment while being sensitive to carbide formation on grain boundaries. The gradual depletion of chromium results from the material and corrosion resistance deteriorates. INCOLOY 800 whose chromium carbide precipitation on grain boundaries in pure water and steam is negligible up to 75O degC and which is not subject to corrosion attacks in the above media and in an oxidizing environment at a temperature to about 700 degC shows the best corrosion resistance. Its favourable properties were tested in long-term operation in the Peach Bottom 1 nuclear power plant where no failures due to corrosion of this material have been recorded since 1967. In view of oxygenic-acid surface corrosion, it is necessary to work in a neutral or slightly basic environment should any one of the two alloys be used for steam generator construction. The results are summed up of an analysis conducted for the Beznau I NOK reactor. Water treatment with ash-free amines can be used as prevention against chemical corrosion mechanisms, although the treatment itself does not ensure corrosion resistance of steam generator key components. (J.B.)

  8. New corrosion issues in gas sweetening plants

    Energy Technology Data Exchange (ETDEWEB)

    Asperger, R.G. (CLI International and Asperger Technologies, Houston, TX (United States))

    Gas treating plants are experiencing corrosion problems which impact on efficiency and safety. While general corrosion is not particularly hazardous in the gas processing industry, local corrosion is very dangerous since it has several different mechanisms, all of which have dangerously high rates, and it occurs at locations which are hard to find and hard to predict. A newly discovered, velocity-dependent type of corrosion is reported. It is related to yet-undefined species which cause excessively high corrosion in areas of turbulence. This accelerated corrosion is not due to erosion or cavitation, but to a diffusion-limited reaction accelerated by turbulence. A full-flow test loop was built to evaluate the corrosiveness of gas plant solutions at their normal temperature and flow rates. Test runs were conducted with Co[sub 2]-loaded amine solutions for periods of 12 days. Carbon steel specimens mounted in the test loop were examined and corrosion rates calculated. Chromium alloys were shown to be attacked by corrodents in the low-velocity part of the loop and very aggressively attacked in the high-velocity part. The tests demonstrate the need for rigorous monitoring of corrosion in areas of higher velocity such as piping elbows and other points of turbulence. 5 refs., 2 figs., 3 tabs.

  9. Boric Acid Corrosion of Concrete Rebar

    Directory of Open Access Journals (Sweden)

    Yang L.

    2013-07-01

    Full Text Available Borated water leakage through spent fuel pools (SFPs at pressurized water reactors is a concern because it could cause corrosion of reinforcement steel in the concrete structure and compromise the integrity of the structure. Because corrosion rate of carbon steel in concrete in the presence of boric acid is lacking in published literature and available data are equivocal on the effect of boric acid on rebar corrosion, corrosion rate measurements were conducted in this study using several test methods. Rebar corrosion rates were measured in (i borated water flowing in a simulated concrete crack, (ii borated water flowing over a concrete surface, (iii borated water that has reacted with concrete, and (iv 2,400 ppm boric acid solutions with pH adjusted to a range of 6.0 to 7.7. The corrosion rates were measured using coupled multielectrode array sensor (CMAS and linear polarization resistance (LPR probes, both made using carbon steel. The results indicate that rebar corrosion rates are low (~1 μm/yr or lesswhen the solution pH is ~7.1 or higher. Below pH ~7.1, the corrosion rate increases with decreasing pH and can reach ~100 μm/yr in solutions with pH less than ~6.7. The threshold pH for carbon steel corrosion in borated solution is between 6.8 and 7.3.

  10. Development of Flow Accelerated Corrosion Reduction Technology

    Energy Technology Data Exchange (ETDEWEB)

    Heo, Min Bum; Choi, Won Yeol; Lee, Jong Chan; Lim, Dong Seok; Kwon, Byung Il; Ku, Hee Kwon; Kim, Jong Uk [FNC Tech, Yongin (Korea, Republic of)

    2015-10-15

    Development of flow accelerated corrosion reduction technology is necessary for prevent this kind of accidents. This study deals with development of flow accelerated corrosion reduction technology through platinum injection and developed of flow accelerated corrosion reduction technology by imitating water chemical condition in PWR secondary system in practice. In addition, in order to get reliability of water chemical simulator in PWR secondary system, analyzed and compared with test result through CFD analysis. This study composed test device that can simulate water chemical environment in PWR secondary system, in order to develop flow accelerated corrosion reduction , and evaluated the ratio of corrosion in water chemical environment in PWR secondary system. In conclusion, corrosion ratio of low alloy steel material that includes more Cr and Mo was lower. And the results were confirmed to be the maximum corrosion rate in the case that replicate the 90 elbow. Additionally, inserted Pt nano particle for developing flow accelerated corrosion rate reduction technology, the test results, it was confirmed for about 80% of the flow accelerated corrosion rate reduction than before input.

  11. Corrosion Fatigue in District Heating Water Tanks

    DEFF Research Database (Denmark)

    Maahn, Ernst Emanuel

    1996-01-01

    Three candidate materials for construction of buffer tanks for district heating water have been tested for corrosion fatigue properties in a district heating water environment. The investigation included Slow Strain Rate Testing of plain tensile specimens, crack initiation testing by corrosion...... fatigue of plain tensile specimens and crack growth rate determination for Compact Tensile Specimens under corrosion fatigue conditions. The three materials are equal with respect to stress corrosion sensibility and crack initiation. Crack growth rate is increased with a factor of 4-6 relative to an inert...

  12. Corrosion problems in PWR steam generators

    International Nuclear Information System (INIS)

    Weber, J.; Suery, P.

    1976-01-01

    Examinations on pulled steam generator tubes from the Swiss nuclear power plants Beznau I and II, together with some laboratory tests, may be summarized as follows: Corrosion problems in vertical U-tube steam generators with Alloy 600 as tube material are localized towards relatively narrow regions above the tube sheet where thermohydraulic conditions and, as a consequence thereof, chemical conditions are uncontrolled. Within these zones Alloy 600 is not sufficienthy resistent to caustic or phosphate attack (caustic stress corrosion cracking and general corrosion, resp.). The mechanisms of several corrosion phenomena are not fully understood. (orig.) [de

  13. Fighting corrosion in air pollution control systems

    International Nuclear Information System (INIS)

    Rittenhouse, R.C.

    1991-01-01

    This paper reports that materials is the name of the game for corrosion prevention in air pollution control equipment. Whether the system is already in place, a retrofit, are specified for a new power pant, preventing corrosion is critical, because such deterioration easily undermines reliability. Hence, materials can heavily influence power plant compliance to the 1990 Clean Air Act amendments. Flue gas desulfurization (FGD) systems, perhaps the most vulnerable area to corrosion, are expected to be the method of choice for sulfur removal in many power plants in the near term. Components of these systems have various degrees of susceptibility to corrosion and related problems

  14. Emerging Corrosion Inhibitors for Interfacial Coating

    Directory of Open Access Journals (Sweden)

    Mona Taghavikish

    2017-12-01

    Full Text Available Corrosion is a deterioration of a metal due to reaction with environment. The use of corrosion inhibitors is one of the most effective ways of protecting metal surfaces against corrosion. Their effectiveness is related to the chemical composition, their molecular structures and affinities for adsorption on the metal surface. This review focuses on the potential of ionic liquid, polyionic liquid (PIL and graphene as promising corrosion inhibitors in emerging coatings due to their remarkable properties and various embedment or fabrication strategies. The review begins with a precise description of the synthesis, characterization and structure-property-performance relationship of such inhibitors for anti-corrosion coatings. It establishes a platform for the formation of new generation of PIL based coatings and shows that PIL corrosion inhibitors with various heteroatoms in different form can be employed for corrosion protection with higher barrier properties and protection of metal surface. However, such study is still in its infancy and there is significant scope to further develop new structures of PIL based corrosion inhibitors and coatings and study their behaviour in protection of metals. Besides, it is identified that the combination of ionic liquid, PIL and graphene could possibly contribute to the development of the ultimate corrosion inhibitor based coating.

  15. Corrosion behavior of 2205 duplex stainless steel.

    Science.gov (United States)

    Platt, J A; Guzman, A; Zuccari, A; Thornburg, D W; Rhodes, B F; Oshida, Y; Moore, B K

    1997-07-01

    The corrosion of 2205 duplex stainless steel was compared with that of AISI type 316L stainless steel. The 2205 stainless steel is a potential orthodontic bracket material with low nickel content (4 to 6 wt%), whereas the 316L stainless steel (nickel content: 10 to 14 wt%) is a currently used bracket material. Both stainless steels were subjected to electrochemical and immersion (crevice) corrosion tests in 37 degrees C, 0.9 wt% sodium chloride solution. Electrochemical testing indicates that 2205 has a longer passivation range than 316L. The corrosion rate of 2205 was 0.416 MPY (milli-inch per year), whereas 316L exhibited 0.647 MPY. When 2205 was coupled to 316L with equal surface area ratio, the corrosion rate of 2205 reduced to 0.260 MPY, indicating that 316L stainless steel behaved like a sacrificial anode. When 316L is coupled with NiTi, TMA, or stainless steel arch wire and was subjected to the immersion corrosion test, it was found that 316L suffered from crevice corrosion. On the other hand, 2205 stainless steel did not show any localized crevice corrosion, although the surface of 2205 was covered with corrosion products, formed when coupled to NiTi and stainless steel wires. This study indicates that considering corrosion resistance, 2205 duplex stainless steel is an improved alternative to 316L for orthodontic bracket fabrication when used in conjunction with titanium, its alloys, or stainless steel arch wires.

  16. Kinetics of steel corrosion in water

    International Nuclear Information System (INIS)

    Vettegren', V.I.; Bashkarev, A.Ya.; Danchukov, K.G.; Morozov, G.I.

    2003-01-01

    Kinetics of corrosion damage accumulation in steels of different composition (Cr-Ni-Mo-Ti, Cr-Ni-Mn-N-V, Cr-Ni-N-Mn-Mo, Cr-Ni-Nb, Cr-Ni-Ti, Cr-Mn-Ni, Mn-Al-Nb-Si, Mn-Cr-Al-Si and Mn-Al-Si) in NaCl solution and in sea water was studied. It is shown that degree of corrosion damage relates to time according to the first order reaction expression. The values of corrosion activation energy and of parameter characterizing protection properties of corrosion film are determined [ru

  17. Influence of corrosion layers on quantitative analysis

    International Nuclear Information System (INIS)

    Denker, A.; Bohne, W.; Opitz-Coutureau, J.; Rauschenberg, J.; Roehrich, J.; Strub, E.

    2005-01-01

    Art historians and restorers in charge of ancient metal objects are often reluctant to remove the corrosion layer evolved over time, as this would change the appearance of the artefact dramatically. Therefore, when an elemental analysis of the objects is required, this has to be done by penetrating the corrosion layer. In this work the influence of corrosion was studied on Chinese and Roman coins, where removal of oxidized material was possible. Measurements on spots with and without corrosion are presented and the results discussed

  18. Recent Corrosion Research Trends in Weld Joints

    International Nuclear Information System (INIS)

    Kim, Hwan Tae; Kil, Sang Cheol; Hwang, Woon Suk

    2007-01-01

    The increasing interest in the corrosion properties of weld joints in the corrosive environment is placing stringent demands on the manufacturing techniques and performance requirements, and the manufacture employs the high quality and efficiency welding process to produce welds. Welding plays an important role in the fabrication of chemical plants, nuclear power plant, ship construction, and this has led to an increasing attention to the corrosion resistant weld joints. This paper covers recent technical trends of welding technologies for corrosion resistance properties including the COMPENDEX DB analysis of welding materials, welding process, and welding fabrications

  19. Corrosion probe. Innovative technology summary report

    International Nuclear Information System (INIS)

    1999-05-01

    Over 253 million liters of high-level waste (HLW) generated from plutonium production is stored in mild steel tanks at the Department of Energy (DOE) Hanford Site. Corrosion monitoring of double-shell storage tanks (DSTs) is currently performed at Hanford using a combination of process knowledge and tank waste sampling and analysis. Available technologies for corrosion monitoring have progressed to a point where it is feasible to monitor and control corrosion by on-line monitoring of the corrosion process and direct addition of corrosion inhibitors. The electrochemical noise (EN) technique deploys EN-based corrosion monitoring probes into storage tanks. This system is specifically designed to measure corrosion rates and detect changes in waste chemistry that trigger the onset of pitting and cracking. These on-line probes can determine whether additional corrosion inhibitor is required and, if so, provide information on an effective end point to the corrosion inhibitor addition procedure. This report describes the technology, its performance, its application, costs, regulatory and policy issues, and lessons learned

  20. Análise da resistência à corrosão por pite em soldas de reparo pelo processo TIG em aço inoxidável superduplex UNS S32750 Analysis of pitting corrosion resistance in welding repair by GTAW procedure in a superduplex stainless steel UNS S32750

    Directory of Open Access Journals (Sweden)

    Juliana Primo Basílio de Souza

    2011-06-01

    Full Text Available Atualmente, os aços inoxidáveis superduplex (AISD estão sendo muito empregados no Brasil em setores industriais tais como petroquímico, energético, naval e plataformas offshore, tendo vasta aplicação em vasos de pressão em processos críticos, trocadores de calor, reatores, tubulações, umbilicais, digestores, bombas e naqueles componentes onde a produtividade contínua é essencial e o custo não é a maior limitação. No entanto, durante processos de fabricação e montagem, assim como na vida em serviço destes componentes de processo pode existir a necessidade eventual de efetuar soldagens de reparo. Deste modo, o presente trabalho, visa avaliar a microestrutura e os valores de resistência à corrosão por pites na zona termicamente afetada (ZTA e metal de solda do AISD UNS S32750 durante a simulação de um processo de reparo mediante a utilização do processo de soldagem TIG (GTAW. Os resultados obtidos permitem estabelecer diretrizes para a realização de procedimentos de soldagem de reparo em AISD.Currently superduplex stainless steels (SDSS are being extensively employed in the petrochemical, power generation, naval and offshore industries. The uses of these materials are: pressure vessels for critical processes, heat exchangers, reactors, pipes, umbilicals, digesters, pumps and other facilities where continuous use is essential and cost is not the main limitation. However, during fabrication and assembly, or as consequence of service, repair welding operations may be necessary. Thus, in this study a simulation of welding repair by GTAW process was performed in a SDSS UNS S32750. The objective of this work was to evaluate the microstructure and the values of critical pitting resistance (CPT in the weld metal, heat affected zone and base metal. The results obtained allows the determination of welding procedures and recommendations useful to the welding repair of SDSS.

  1. Corrosion of steel structures in sea-bed sediment

    Indian Academy of Sciences (India)

    Unknown

    corrosion mechanism, measurement of metal corrosion rate, corrosion ... cables, steel rigs, pipelines and other marine facilities, is ..... make high strength steel material to crack with stress ... of SBS has yet been very limited, and selection of.

  2. corrosion response of low carbon steel in tropical road mud

    African Journals Online (AJOL)

    Dr Obe

    Corrosion Mitigation efforts using readily available anti- corrosion coatings to protect low carbon steel test coupons against the ... The following protective coating devices were effective: ..... 2 West, J.M (1986): Basic Corrosion and Oxidation,.

  3. Propagation of steel corrosion in concrete: Experimental and numerical investigations

    DEFF Research Database (Denmark)

    Michel, Alexander; Otieno, M.; Stang, Henrik

    2016-01-01

    This paper focuses on experimental and numerical investigations of the propagation phase of reinforcement corrosion to determine anodic and cathodic Tafel constants and exchange current densities, from corrosion current density and corrosion potential measurements. The experimental program includ...

  4. Analysis of corrosive environmental factors of seabed sediment

    Indian Academy of Sciences (India)

    Unknown

    Seabed sediment; corrosion; environmental factors. 1. Introduction. The corrosion ... plays an important role in the corrosion behaviour of steel in sediment. Figure 2b shows the change in oxidation-reduction po- tential, Eh with distance from ...

  5. Corrosion problems and solutions in oil refining and petrochemical industry

    CERN Document Server

    Groysman, Alec

    2017-01-01

    This book addresses corrosion problems and their solutions at facilities in the oil refining and petrochemical industry, including cooling water and boiler feed water units. Further, it describes and analyzes corrosion control actions, corrosion monitoring, and corrosion management. Corrosion problems are a perennial issue in the oil refining and petrochemical industry, as they lead to a deterioration of the functional properties of metallic equipment and harm the environment – both of which need to be protected for the sake of current and future generations. Accordingly, this book examines and analyzes typical and atypical corrosion failure cases and their prevention at refineries and petrochemical facilities, including problems with: pipelines, tanks, furnaces, distillation columns, absorbers, heat exchangers, and pumps. In addition, it describes naphthenic acid corrosion, stress corrosion cracking, hydrogen damages, sulfidic corrosion, microbiologically induced corrosion, erosion-corrosion, and corrosion...

  6. Corrosion process studies in a nuclear waste container

    International Nuclear Information System (INIS)

    Guasp, Ruben A.; Lanzani, Liliana A.; Coronel, Pascual; Bruzzoni, Pablo; Semino, Carlos J.

    1999-01-01

    Latest results on corrosion behavior studies on high activity nuclear waste container are reported. Corrosion evaluation on lead base alloys and modeling to predict carbon steel external container cover generalized corrosion, are the main issues of these studies. (author)

  7. Assessing Level and Effectiveness of Corrosion Education in the UAE

    OpenAIRE

    Lim, Hwee Ling

    2012-01-01

    The consequences of corrosion can be minimized by an engineering workforce well trained in corrosion fundamentals and management. Since the United Arab Emirates incurs the second highest cost of corrosion after Saudi Arabia, this paper examined the quality of corrosion education in the UAE. Surveys with academia and industry respondents showed that dedicated corrosion courses and engineering courses that integrated corrosion into the curricula were available in UAE universities, but graduates...

  8. Events as Power Source: Wireless Sustainable Corrosion Monitoring

    OpenAIRE

    Sun, Guodong; Qiao, Guofu; Zhao, Lin; Chen, Zhibo

    2013-01-01

    This study presents and implements a corrosion-monitoring wireless sensor platform, EPS (Events as Power Source), which monitors the corrosion events in reinforced concrete (RC) structures, while being powered by the micro-energy released from the corrosion process. In EPS, the proposed corrosion-sensing device serves both as the signal source for identifying corrosion and as the power source for driving the sensor mote, because the corrosion process (event) releases electric energy; this is ...

  9. Corrosion test by low-temperature coal tar

    Energy Technology Data Exchange (ETDEWEB)

    Ando, S; Yamamoto, S

    1952-01-01

    Corrosive actions of various fractions of low-temperature coal tar against mild steel or Cr 13-steel were compared at their boiling states. Corrosions became severe when the boiling points exceeded 240/sup 0/. The acidic fractions were more corrosive. In all instances, corrosion was excessive at the beginning of immersion testing and then gradually became mild; boiling accelerated the corrosion. Cr 13-steel was corrosion-resistant to low-temperature coal-tar fractions.

  10. Corrosion '98: 53. annual conference and exposition, proceedings

    International Nuclear Information System (INIS)

    Anon.

    1998-01-01

    This conference was divided into the following sections: Corrosion in Gas Treating; Problems and Solutions in Commercial Building Water Systems; Green Corrosion/Scale Inhibitors; Atmospheric Corrosion; AIRPOL Update/98; Rubber Lining--Answers to Many Problems; Interference Problems; Environmental Assisted Cracking: Fundamental Research and Industrial Applications; Corrosion in Nuclear Systems; New Developments in Scale and Deposit Control; Corrosion and Corrosion Protection in the Transportation Industries; What's All the Noise About--Electrochemical That Is; Refining Industry Corrosion; Corrosion Problems in Military Hardware: Case Histories, Fixes and Lessons Learned; Cathodic Protection Test Methods and Instrumentation for Underground and On-grade Pipelines and Tanks; Recent Developments in Volatile Corrosion Inhibitors; Corrosion in Supercritical Fluids; Microbiologically Influenced Corrosion; Advances in Understanding and Controlling CO 2 Corrosion; Managing Corrosion with Plastics; Material Developments for Use in Exploration and Production Environments; Corrosion in Cold Regions; The Effect of Downsizing and Outsourcing on Cooling System Monitoring and Control Practices; New Developments in Mechanical and Chemical Industrial Cleaning; Mineral Scale Deposit Control in Oilfield Related Operations; Biocides in Cooling Water; Corrosion and Corrosion Control of Reinforced Concrete Structures; Materials Performance for Fossil Energy Conversion Systems; Marine corrosion; Thermal Spray--Coating and Corrosion Control; Flow Effects on Corrosion in Oil and Gas Production; Corrosion Measurement Technologies; Internal Pipeline Monitoring--Corrosion Monitoring, Intelligent Pigging and Leak Detection; Cathodic Protection in Natural Waters; Corrosion in Radioactive Liquid Waste Systems; On-line Hydrogen Permeation Monitoring Equipment and Techniques, State of the Art; Water Reuse and Recovery; Performance of Materials in High Temperature Environments; Advances in Motor

  11. NASA's Corrosion Technology Laboratory at the Kennedy Space Center: Anticipating, Managing, and Preventing Corrosion

    Science.gov (United States)

    Calle, Luz Marina

    2014-01-01

    Corrosion is the degradation of a material that results from its interaction with the environment. The marine environment at NASAs Kennedy Space Center (KSC) has been documented by ASM International (formerly American Society for Metals) as the most corrosive in the United States. With the introduction of the Space Shuttle in 1981, the already highly corrosive conditions at the launch pads were rendered even more severe by the 70 tons of highly corrosive hydrochloric acid that were generated by the solid rocket boosters. Numerous failures at the launch pads are caused by corrosion.The structural integrity of ground infrastructure and flight hardware is critical to the success, safety, cost, and sustainability of space missions. As a result of fifty years of experience with launch and ground operations in a natural marine environment that is highly corrosive, NASAs Corrosion Technology Laboratory at KSC is a major source of corrosion control expertise in the launch and other environments. Throughout its history, the Laboratory has evolved from what started as an atmospheric exposure facility near NASAs launch pads into a world-wide recognized capability that provides technical innovations and engineering services in all areas of corrosion for NASA and external customers.This presentation will provide a historical overview of the role of NASAs Corrosion Technology in anticipating, managing, and preventing corrosion. One important challenge in managing and preventing corrosion involves the detrimental impact on humans and the environment of what have been very effective corrosion control strategies. This challenge has motivated the development of new corrosion control technologies that are more effective and environmentally friendly. Strategies for improved corrosion protection and durability can have a huge impact on the economic sustainability of human spaceflight operations.

  12. Environmental Friendly Coatings and Corrosion Prevention For Flight Hardware Project

    Science.gov (United States)

    Calle, Luz

    2014-01-01

    Identify, test and develop qualification criteria for environmentally friendly corrosion protective coatings and corrosion preventative compounds (CPC's) for flight hardware an ground support equipment.

  13. Materials corrosion and protection at high temperatures

    International Nuclear Information System (INIS)

    Balbaud, F.; Desgranges, Clara; Martinelli, Laure; Rouillard, Fabien; Duhamel, Cecile; Marchetti, Loic; Perrin, Stephane; Molins, Regine; Chevalier, S.; Heintz, O.; David, N.; Fiorani, J.M.; Vilasi, M.; Wouters, Y.; Galerie, A.; Mangelinck, D.; Viguier, B.; Monceau, D.; Soustelle, M.; Pijolat, M.; Favergeon, J.; Brancherie, D.; Moulin, G.; Dawi, K.; Wolski, K.; Barnier, V.; Rebillat, F.; Lavigne, O.; Brossard, J.M.; Ropital, F.; Mougin, J.

    2011-01-01

    This book was made from the lectures given in 2010 at the thematic school on 'materials corrosion and protection at high temperatures'. It gathers the contributions from scientists and engineers coming from various communities and presents a state-of-the-art of the scientific and technological developments concerning the behaviour of materials at high temperature, in aggressive environments and in various domains (aerospace, nuclear, energy valorization, and chemical industries). It supplies pedagogical tools to grasp high temperature corrosion thanks to the understanding of oxidation mechanisms. It proposes some protection solutions for materials and structures. Content: 1 - corrosion costs; macro-economical and metallurgical approach; 2 - basic concepts of thermo-chemistry; 3 - introduction to the Calphad (calculation of phase diagrams) method; 4 - use of the thermodynamic tool: application to pack-cementation; 5 - elements of crystallography and of real solids description; 6 - diffusion in solids; 7 - notions of mechanics inside crystals; 8 - high temperature corrosion: phenomena, models, simulations; 9 - pseudo-stationary regime in heterogeneous kinetics; 10 - nucleation, growth and kinetic models; 11 - test experiments in heterogeneous kinetics; 12 - mechanical aspects of metal/oxide systems; 13 - coupling phenomena in high temperature oxidation; 14 - other corrosion types; 15 - methods of oxidized surfaces analysis at micro- and nano-scales; 16 - use of SIMS in the study of high temperature corrosion of metals and alloys; 17 - oxidation of ceramics and of ceramic matrix composite materials; 18 - protective coatings against corrosion and oxidation; 19 - high temperature corrosion in the 4. generation of nuclear reactor systems; 20 - heat exchangers corrosion in municipal waste energy valorization facilities; 21 - high temperature corrosion in oil refining and petrochemistry; 22 - high temperature corrosion in new energies industry. (J.S.)

  14. Corrosion potential monitoring in nuclear power environments

    International Nuclear Information System (INIS)

    Molander, A.

    2004-01-01

    Full text of publication follows: corrosion monitoring. The corrosion potential is usually an important parameter or even the prime parameter for many types of corrosion processes. One typical example of the strong influence of the corrosion potential on corrosion performance is stress corrosion of sensitized stainless steel in pure high temperature water corresponding to boiling water conditions. The use of in-plant monitoring to follow the effect of hydrogen addition to mitigate stress corrosion in boiling water reactors is now a well-established technique. However, different relations between the corrosion potential of stainless steel and the oxidant concentration have been published and only recently an improved understanding of the electrochemical reactions and other conditions that determine the corrosion potential in BWR systems have been reached. This improved knowledge will be reviewed in this paper. Electrochemical measurements has also been performed in PWR systems and mainly the feedwater system on the secondary side of PWRs. The measurements performed so far have shown that electrochemical measurements are a very sensitive tool to detect and follow oxygen transients in the feedwater system. Also determinations of the minimum hydrazine dosage to the feedwater have been performed. However, PWR secondary side monitoring has not yet been utilized to the same level as BWR hydrogen water chemistry surveillance. The future potential of corrosion potential monitoring will be discussed. Electrochemical measurements are also performed in other reactor systems and in other types of reactors. Experiences will be briefly reviewed. In a BWR on hydrogen water chemistry and in the PWR secondary system the corrosion potentials show a large variation between different system parts. To postulate the material behavior at different locations the local chemical and electrochemical conditions must be known. Thus, modeling of chemical and electrochemical conditions along

  15. Screening of soil corrosivity by field testing: Results and design of an electrochemical soil corrosion probe

    DEFF Research Database (Denmark)

    Nielsen, Lars vendelbo; Bruun, Niels Kåre

    1996-01-01

    The corrosivity of different types of soil have been assessed by exposing carbon-steel plates at 50 different locations in Denmark for an extended period of time. The investigations included weight loss measurements and analysis of the chemical compositions of the corrosion products formed...... on the plates during exposure. An electrochemical soil corrosion probe has been designed and manufactured allowing for simultaneous measurements of several qauntities to predict corrosion. The probe consists of individual sections capable of measuring redox-potential, corrosion potential, soil resistivity...

  16. High Temperature Corrosion under Laboratory Conditions Simulating Biomass-Firing: A Comprehensive Characterization of Corrosion Products

    DEFF Research Database (Denmark)

    Okoro, Sunday Chukwudi; Montgomery, Melanie; Jappe Frandsen, Flemming

    2014-01-01

    characterization of the corrosion products. The corrosion products consisted of three layers: i) the outermost layer consisting of a mixed layer of K2SO4 and FexOy on a partly molten layer of the initial deposit, ii) the middle layer consists of spinel (FeCr2O4) and Fe2O3, and iii) the innermost layer is a sponge......-like Ni3S2 containing layer. At the corrosion front, Cl-rich protrusions were observed. Results indicate that selective corrosion of Fe and Cr by Cl, active oxidation and sulphidation attack of Ni are possible corrosion mechanisms....

  17. Effect of Flow Velocity on Corrosion Rate and Corrosion Protection Current of Marine Material

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seong Jong [Kunsan National University, Kunsan (Korea, Republic of); Han, Min Su; Jang, Seok Ki; Kim, Seong Jong [Mokpo National Maritime University, Mokpo (Korea, Republic of)

    2015-10-15

    In spite of highly advanced paint coating techniques, corrosion damage of marine metal and alloys increase more and more due to inherent micro-cracks and porosities in coatings formed during the coating process. Furthermore, flowing seawater conditions promote the breakdown of the protective oxide of the materials introducing more oxygen into marine environments, leading to the acceleration of corrosion. Various corrosion protection methods are available to prevent steel from marine corrosion. Cathodic protection is one of the useful corrosion protection methods by which the potential of the corroded metal is intentionally lowered to an immune state having the advantage of providing additional protection barriers to steel exposed to aqueous corrosion or soil corrosion, in addition to the coating. In the present investigation, the effect of flow velocity was examined for the determination of the optimum corrosion protection current density in cathodic protection as well as the corrosion rate of the steel. It is demonstrated from the result that the material corrosion under dynamic flowing conditions seems more prone to corrosion than under static conditions.

  18. The Effects of Corrosive Chemicals on Corrosion Rate of Steel Reinforcement Bars: II. Swamp Sludges

    Directory of Open Access Journals (Sweden)

    Henki Ashadi

    2010-10-01

    Full Text Available A polluted environment will influence the building age. The objective of this research was to find out the influence of corrosive chemicals within the sludge swamp area with the corrosion rate of steel concrete. Corrosion in steel concrete usually occur in acid area which contain of SO42-, Cl- and NO3-. The research treatment used by emerging ST 37 andST 60 within 60 days in 'polluted' sludge swamp area. Three variation of 'polluted' swamp sludge were made by increasing the concentration a corrosive unsure up to 1X, 5X and 10X. The corrosion rate measured by using an Immersion Method. The result of Immersion test showed that sulphate had a greatest influence to corrosion rate of ST 37 and ST 60 and followed by chloride and nitrate. Corrosion rate value for ST 37 was 17.58 mpy and for ST 60 was 12.47 mpy.

  19. General Corrosion and Localized Corrosion of the Drip Shield

    Energy Technology Data Exchange (ETDEWEB)

    F. Hua; K. Mon

    2003-06-24

    The recommended waste package (WP) design is described in BSC (2001a). The design includes a double-wall WP underneath a protective drip shield (DS) (BSC 2003a). The purpose of the process-level models developed in this report is to model dry oxidation (DOX), general corrosion (GC) and localized corrosion (LC) of the DS plate material, which is made of Ti Grade 7. The DS design also includes structural supports fabricated from Ti Grade 24. Degradation of Ti Grade 24 is not considered in this report. The DS provides protection for the waste package outer barrier (WPOB) both as a barrier to seepage water contact and a physical barrier to potential rockfall. This Model Report (MR) serves as a feed to the Integrated Waste Package Degradation Model (IWPD) analyses, and was developed in accordance with the Technical Work Plan (TWP) (BSC 2002a). The models contained in this report serve as a basis to determine whether or not the performance requirements for the DS can be met.

  20. General Corrosion and Localized Corrosion of the Drip Shield

    International Nuclear Information System (INIS)

    Hua, F.; Mon, K.

    2003-01-01

    The recommended waste package (WP) design is described in BSC (2001a). The design includes a double-wall WP underneath a protective drip shield (DS) (BSC 2003a). The purpose of the process-level models developed in this report is to model dry oxidation (DOX), general corrosion (GC) and localized corrosion (LC) of the DS plate material, which is made of Ti Grade 7. The DS design also includes structural supports fabricated from Ti Grade 24. Degradation of Ti Grade 24 is not considered in this report. The DS provides protection for the waste package outer barrier (WPOB) both as a barrier to seepage water contact and a physical barrier to potential rockfall. This Model Report (MR) serves as a feed to the Integrated Waste Package Degradation Model (IWPD) analyses, and was developed in accordance with the Technical Work Plan (TWP) (BSC 2002a). The models contained in this report serve as a basis to determine whether or not the performance requirements for the DS can be met

  1. Silicate glasses corrosion. Texture analysis of the corrosion layer

    International Nuclear Information System (INIS)

    Portal, Sabine

    2001-01-01

    We have studied the kinetic and the texture evolution of the corroded layer that forms on glass surfaces exposed to acidic solutions. The corroded layer is depleted in alkali cations and is produced by an ion exchange mechanism. It is porous and shows a lower refractive index than the one of the bulk glass. Spectroscopic ellipsometry allows determining the thickness of the layer and its refractive index. Several other techniques have been developed for characterizing the corrosion behaviour of glass surfaces: porosity is thus investigated by adsorption-desorption of nitrogen; the thickness and the composition of the layer are studied by secondary ion mass spectroscopy (S.I.M.S.); sodium concentration in the solution has been analyzed by atomic absorption. This study shows the importance of leaching conditions and glass preparation. The type of drying employed is susceptible to modify the texture and the structure of the layer. The layers produced in the early stages of the leaching process are not easily detectable. The different results lead however to the same conclusion: after a strong increase of porosity, a densification of the layer is observed with increasing time. The evolution of the layer texture could therefore modify the kinetic of the glass corrosion. (author) [fr

  2. Corrosion protected reversing heat exchanger

    International Nuclear Information System (INIS)

    Zawierucha, R.

    1984-01-01

    A reversing heat exchanger of the plate and fin type having multiple aluminum parting sheets in a stacked arrangement with corrugated fins separating the sheets to form multiple flow paths, means for closing the ends of the sheets, an input manifold arrangement of headers for the warm end of of the exchanger and an output manifold arrangement for the cold end of the exchanger with the input air feed stream header and the waste gas exhaust header having an alloy of zinc and aluminum coated on the inside surface for providing corrosion protection to the stack

  3. Galvanic corrosion in odontological alloys

    International Nuclear Information System (INIS)

    Riesgo, O.; Bianchi, G.L.; Duffo, G.S.

    1993-01-01

    Galvanic corrosion can occur when different alloys are placed in direct contact within the oral cavity or within tissues. Concern has been expressed associated with the coupling of selected restorative materials as well as implant material with various alloys used for restorative procedures. This could be critical if the crown or bridge had subgingival finish line with a metallic zone in contact with the tissue, and the implant was made in titanium alloy. The present work shows the results of galvanic coupling studies done on implants of titanium alloy connected to nickel-chromium and cobalt-chromium alloys. (Author)

  4. Corrosion Chemistry in Inhibited HDA.

    Science.gov (United States)

    1980-11-30

    which are likely to resemble authentic Modified HDA corrosion products, and reactions of a range of metal fluorides with difluorphosphoric acid have i...Introduction 10 (b) Solutions of HF in nitric acid and in HDA 10 (c) Solutions of PF5 in HDA 10 (d) Solutions of HPO 2 F2 in HDA 15 (e) Solutions of...of metals with HPO F in HDA 2 2 solution. 166 Iron. 166 Nickel. 166 (c) Reactions of metal fluorides with difluorophosphoric acid . 169 B-FeF 3.3H 2 0

  5. [Microbiological corrosion of aluminum alloys].

    Science.gov (United States)

    Smirnov, V F; Belov, D V; Sokolova, T N; Kuzina, O V; Kartashov, V R

    2008-01-01

    Biological corrosion of ADO quality aluminum and aluminum-based construction materials (alloys V65, D16, and D16T) was studied. Thirteen microscopic fungus species and six bacterial species proved to be able to attack aluminum and its alloys. It was found that biocorrosion of metals by microscopic fungi and bacteria was mediated by certain exometabolites. Experiments on biocorrosion of the materials by the microscopic fungus Alternaria alternata, the most active biodegrader, demonstrated that the micromycete attack started with the appearance of exudate with pH 8-9 on end faces of the samples.

  6. Corrosion effects on soda lime glass

    NARCIS (Netherlands)

    Veer, F.A.; Rodichev, Y.M.

    2010-01-01

    Although soda lime glass is the most common used transparent material in architecture, little is known about the corrosion effects on long term strength and the interaction between corrosion and defects. Extensive testing on soda lime bars under different environmental conditions and different

  7. Computer-Aided Corrosion Program Management

    Science.gov (United States)

    MacDowell, Louis

    2010-01-01

    This viewgraph presentation reviews Computer-Aided Corrosion Program Management at John F. Kennedy Space Center. The contents include: 1) Corrosion at the Kennedy Space Center (KSC); 2) Requirements and Objectives; 3) Program Description, Background and History; 4) Approach and Implementation; 5) Challenges; 6) Lessons Learned; 7) Successes and Benefits; and 8) Summary and Conclusions.

  8. Drywell corrosion stopped at Oyster Creek

    International Nuclear Information System (INIS)

    Lipford, B.L.; Flynn, J.C.

    1993-01-01

    This article describes the detection of corrosion on the drywell containment vessel of Oyster Creek Nuclear Plant and the application of a protective coating to repair the drywell. The topics of the article include drywell design features, identification of the problem, initial action, drywell corrosion, failure of cathodic protection, long-term repair, and repair results

  9. A Course in Electrochemical and Corrosion Engineering.

    Science.gov (United States)

    Van Zee, John

    1985-01-01

    Describes a course designed to show similarities between electrochemistry and corrosion engineering and to show graduate students that electrochemical and corrosion engineering can be accomplished by extending their knowledge of chemical engineering models. Includes course outline, textbooks selected, and teaching methods used. (JN)

  10. Dissolution properties of cerium dibutylphosphate corrosion inhibitors

    NARCIS (Netherlands)

    Soestbergen, van M.; Erich, S.J.F.; Huinink, H.P.; Adan, O.C.G.

    2013-01-01

    The corrosion inhibitor cerium dibutylphosphate, Ce(dbp)3, prevents corrosion by cerium and dbp deposition at the alkaline cathode and acidic anode respectively. The pH dependent Ce(dbp)3 solubility seems to play an essential role in the inhibition degree. We found that Ce(dbp)3 scarcely dissolves

  11. Corrosion and compatibility in liquid alkali metals

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    The literature dealing with liquid alkali metal corrosion of vanadium and its alloys is reviewed in the following subsections. Attention is given to both lithium and sodium data. Preceding this review, a brief outline of the current state of understanding of liquid metal corrosion mechanisms is provided

  12. EXTRACT OF COMBRETUM MICRANTHUM AS CORROSION ...

    African Journals Online (AJOL)

    user

    2016-10-04

    Oct 4, 2016 ... methanol extract CM is a good adsorption inhibitor for the corrosion of Al-Si-Mg in 3.5wt% NaCl solution. Tafel polarization analysis indicates that the studied plant extract is a mixed ..... (2008). [2] Shreir, L. L., Jarman, R. A. and Burstein, G. T.. Corrosion ... [6] Maqsood Ahmad Malik, Mohammad Ali Hashim,.

  13. Modeling of Corrosion-induced Concrete Damage

    DEFF Research Database (Denmark)

    Thybo, Anna Emilie A.; Michel, Alexander; Stang, Henrik

    2013-01-01

    In the present paper a finite element model is introduced to simulate corrosion-induced damage in concrete. The model takes into account the penetration of corrosion products into the concrete as well as non-uniform formation of corrosion products around the reinforcement. To ac-count for the non...... of corrosion products affects both the time-to cover cracking and the crack width at the concrete surface.......In the present paper a finite element model is introduced to simulate corrosion-induced damage in concrete. The model takes into account the penetration of corrosion products into the concrete as well as non-uniform formation of corrosion products around the reinforcement. To ac-count for the non......-uniform formation of corrosion products at the concrete/reinforcement interface, a deterministic approach is used. The model gives good estimates of both deformations in the con-crete/reinforcement interface and crack width when compared to experimental data. Further, it is shown that non-uniform deposition...

  14. Microbiologically influenced corrosion in ship ballast tanks

    NARCIS (Netherlands)

    Heyer, A.

    2013-01-01

    Microbiologically influenced corrosion (MIC) is known to be a dangerous process in ship tanks due to its rapid and yet unpredictable occurrence, leading to extremely fast local corrosion, possibly jeopardizing the structural integrity, in a relatively short time. This project focuses on a

  15. 49 CFR 193.2625 - Corrosion protection.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Corrosion protection. 193.2625 Section 193.2625 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY...: FEDERAL SAFETY STANDARDS Maintenance § 193.2625 Corrosion protection. (a) Each operator shall determine...

  16. Corrosion problems in nuclear power industry

    International Nuclear Information System (INIS)

    Flis, J.; Janik-Czachor, M.

    1980-01-01

    Characteristics were given of steels and alloys used in the PWR nuclear power plants and of water used in the primary and secondary systems. Corrosion damages of materials and installations were described. It was indicated that the damages were due mainly to stress corrosion cracking. Main preventive methods were listed. (author)

  17. Corrosion mechanism of copper in palm biodiesel

    International Nuclear Information System (INIS)

    Fazal, M.A.; Haseeb, A.S.M.A.; Masjuki, H.H.

    2013-01-01

    Highlights: ► Corrosion of copper in biodiesel increases with the increase of immersion time. ► The corrosion patina is found to be composed of CuO, Cu 2 O, CuCO 3 and Cu(OH) 2 . ► Green CuCO 3 was found as the major corrosion product. ► The mechanisms governing corrosion of copper in palm biodiesel are discussed. - Abstract: Biodiesel is a promising alternative fuel. However, it causes enhanced corrosion of automotive materials, especially of copper based components. In the present study, corrosion mechanism of copper was investigated by scanning electron microscope (SEM), energy dispersive spectroscopy (EDS), X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS). Compositional change of biodiesel due to the exposure of copper was also investigated. Corrosion patina on copper is found to be composed of Cu 2 O, CuO, Cu(OH) 2 and CuCO 3. Dissolved O 2 , H 2 O, CO 2 and RCOO − radical in biodiesel seem to be the leading factors in enhancing the corrosiveness of biodiesel.

  18. Downhole corrosion mechanisms and mitigation strategies

    Energy Technology Data Exchange (ETDEWEB)

    McDougall, D. [Baker Hughes Canada, Calgary, AB (Canada)

    2010-07-01

    Pipeline corrosion refers to its deterioration because of a reaction with its environment. Although the physical condition of the metal at the anode initiates the corrosion process, it is the chemistry and composition of the electrolyte that controls the rate of the corrosion reaction and the severity of the corrosion. This presentation described the role of corrosion rate accelerators, with particular reference to dissolved gases such as oxygen, hydrogen sulfides and carbon dioxide, as well as pH levels, salinity, flow rate, temperature and presence of solids such as iron sulfides and sulfur. The effects of these accelerators were shown to be additive. Mitigation strategies include using materials such as resistant metal alloys or fiberglass, and applying coatings and chemical inhibitors. The importance of corrosion monitoring was also emphasized, with particular reference to the value of examining the number of corrosion related failures that have occurred over a fixed period of time. It was concluded that the ability to analyze samples of failed materials results in a better understanding of the cause of the failure, and is an integral part of designing any successful corrosion control program. tabs., figs.

  19. A South African corrosion research contribution

    International Nuclear Information System (INIS)

    Robinson, F.P.A.

    1980-01-01

    This paper contains the historical background to the setting up of the S.A. Corrosion Institute. The Metallurgy Department of the University of the Witwatersrand has been a training ground for corrosion scientists and engineers. Most of the research and development carried out has been devoted to stainless steels and more particularly to studying the effects of different alloying elements

  20. Localized corrosion problems in water reactors

    International Nuclear Information System (INIS)

    Coriou, Henri.

    1977-01-01

    Main localized etching on the structure materials of water reactors are studied: stress corrosion on stainless steel 304 (B.W.R), stress corrosion, 'wall thinning' and denting of Inconel 600 vapor generator tubes (P.W.R.). Some mechanisms are examined and practical exemples in reactors are described. Various possible cures are presented [fr