WorldWideScience

Sample records for coronary stenoses in-vitro

  1. Learning-based automatic detection of severe coronary stenoses in CT angiographies

    Science.gov (United States)

    Melki, Imen; Cardon, Cyril; Gogin, Nicolas; Talbot, Hugues; Najman, Laurent

    2014-03-01

    3D cardiac computed tomography angiography (CCTA) is becoming a standard routine for non-invasive heart diseases diagnosis. Thanks to its high negative predictive value, CCTA is increasingly used to decide whether or not the patient should be considered for invasive angiography. However, an accurate assessment of cardiac lesions using this modality is still a time consuming task and needs a high degree of clinical expertise. Thus, providing automatic tool to assist clinicians during the diagnosis task is highly desirable. In this work, we propose a fully automatic approach for accurate severe cardiac stenoses detection. Our algorithm uses the Random Forest classi cation to detect stenotic areas. First, the classi er is trained on 18 CT cardiac exams with CTA reference standard. Then, then classi cation result is used to detect severe stenoses (with a narrowing degree higher than 50%) in a 30 cardiac CT exam database. Features that best captures the di erent stenoses con guration are extracted along the vessel centerlines at di erent scales. To ensure the accuracy against the vessel direction and scale changes, we extract features inside cylindrical patterns with variable directions and radii. Thus, we make sure that the ROIs contains only the vessel walls. The algorithm is evaluated using the Rotterdam Coronary Artery Stenoses Detection and Quantication Evaluation Framework. The evaluation is performed using reference standard quanti cations obtained from quantitative coronary angiography (QCA) and consensus reading of CTA. The obtained results show that we can reliably detect severe stenosis with a sensitivity of 64%.

  2. Noninvasive physiologic assessment of coronary stenoses using cardiac CT.

    Science.gov (United States)

    Xu, Lei; Sun, Zhonghua; Fan, Zhanming

    2015-01-01

    Coronary CT angiography (CCTA) has become an important noninvasive imaging modality in the diagnosis of coronary artery disease (CAD). CCTA enables accurate evaluation of coronary artery stenosis. However, CCTA provides limited information on the physiological significance of stenotic lesions. A noninvasive "one-stop-shop" diagnostic test that can provide both anatomical significance and functional significance of stenotic lesions would be beneficial in the diagnosis and management of CAD. Recently, with the introduction of novel techniques, such as myocardial CT perfusion, CT-derived fractional flow reserve (FFRCT), and transluminal attenuation gradient (TAG), CCTA has emerged as a noninvasive method for the assessment of both anatomy of coronary lesions and its physiological consequences during a single study. This review provides an overview of the current status of new CT techniques for the physiologic assessments of CAD.

  3. Noninvasive Physiologic Assessment of Coronary Stenoses Using Cardiac CT

    Directory of Open Access Journals (Sweden)

    Lei Xu

    2015-01-01

    Full Text Available Coronary CT angiography (CCTA has become an important noninvasive imaging modality in the diagnosis of coronary artery disease (CAD. CCTA enables accurate evaluation of coronary artery stenosis. However, CCTA provides limited information on the physiological significance of stenotic lesions. A noninvasive “one-stop-shop” diagnostic test that can provide both anatomical significance and functional significance of stenotic lesions would be beneficial in the diagnosis and management of CAD. Recently, with the introduction of novel techniques, such as myocardial CT perfusion, CT-derived fractional flow reserve (FFRCT, and transluminal attenuation gradient (TAG, CCTA has emerged as a noninvasive method for the assessment of both anatomy of coronary lesions and its physiological consequences during a single study. This review provides an overview of the current status of new CT techniques for the physiologic assessments of CAD.

  4. Advanced 2-dimensional quantitative coronary angiographic analysis for prediction of fractional flow reserve in intermediate coronary stenoses.

    Science.gov (United States)

    Opolski, Maksymilian P; Pregowski, Jerzy; Kruk, Mariusz; Kepka, Cezary; Staruch, Adam D; Witkowski, Adam

    2014-07-01

    The widespread clinical application of coronary computed tomography angiography (CCTA) has resulted in increased referral patterns of patients with intermediate coronary stenoses to invasive coronary angiography. We evaluated the application of advanced quantitative coronary angiography (A-QCA) for predicting fractional flow reserve (FFR) in intermediate coronary lesions detected on CCTA. Fifty-six patients with 66 single intermediate coronary lesions (≥ 50% to 80% stenosis) on CCTA prospectively underwent coronary angiography and FFR. A-QCA including calculation of the Poiseuille-based index defined as the ratio of lesion length to the fourth power of the minimal lumen diameter (MLD) was performed. Significant stenosis was defined as FFR ≤ 0.80. The mean FFR was 0.86 ± 0.09, and 18 lesions (27%) were functionally significant. FFR correlated with lesion length (R=-0.303, P=0.013), MLD (R=0.527, P44%, and >69%, respectively (maximum negative predictive value of 94% for MLA, maximum positive predictive value of 58% for diameter stenosis). The Poiseuille-based index was the most accurate (C statistic 0.86, sensitivity 100%, specificity 71%, positive predictive value 56%, and negative predictive value 100%) predictor of FFR ≤ 0.80, but showed the lowest interobserver agreement (intraclass correlation coefficient 0.37). A-QCA might be used to rule out significant ischemia in intermediate stenoses detected by CCTA. The diagnostic application of the Poiseuille-based angiographic index is precluded by its high interobserver variability.

  5. Expansion characteristics of coronary stents in focal stenoses

    Directory of Open Access Journals (Sweden)

    Schmidt Wolfram

    2017-09-01

    Full Text Available The presented experimental in vitro approach was designed to assess the expansion behavior of stent systems in a resistant focal stenosis model with respect to a potential dog-boning effect. Five different stent systems (nominal diameter 3.0 mm were investigated. The focal stenosis was simulated by a stainless steel tube (ID ≤ 1.20 mm. Stent expansion was performed using a proprietary test device consisting of a test chamber with 37 °C water, 2-axis laser scanner and a pressure controller.

  6. Non-invasive prediction of hemodynamically significant coronary artery stenoses by contrast density difference in coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Hell, Michaela M., E-mail: michaela.hell@uk-erlangen.de [Department of Cardiology, University of Erlangen (Germany); Dey, Damini [Department of Biomedical Sciences, Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Taper Building, Room A238, 8700 Beverly Boulevard, Los Angeles, CA 90048 (United States); Marwan, Mohamed; Achenbach, Stephan; Schmid, Jasmin; Schuhbaeck, Annika [Department of Cardiology, University of Erlangen (Germany)

    2015-08-15

    Highlights: • Overestimation of coronary lesions by coronary computed tomography angiography and subsequent unnecessary invasive coronary angiography and revascularization is a concern. • Differences in plaque characteristics and contrast density difference between hemodynamically significant and non-significant stenoses, as defined by invasive fractional flow reserve, were assessed. • At a threshold of ≥24%, contrast density difference predicted hemodynamically significant lesions with a specificity of 75%, sensitivity of 33%, PPV of 35% and NPV of 73%. • The determination of contrast density difference required less time than transluminal attenuation gradient measurement. - Abstract: Objectives: Coronary computed tomography angiography (CTA) allows the detection of obstructive coronary artery disease. However, its ability to predict the hemodynamic significance of stenoses is limited. We assessed differences in plaque characteristics and contrast density difference between hemodynamically significant and non-significant stenoses, as defined by invasive fractional flow reserve (FFR). Methods: Lesion characteristics of 59 consecutive patients (72 lesions) in whom invasive FFR was performed in at least one coronary artery with moderate to high-grade stenoses in coronary CTA were evaluated by two experienced readers. Coronary CTA data sets were acquired on a second-generation dual-source CT scanner using retrospectively ECG-gated spiral acquisition or prospectively ECG-triggered axial acquisition mode. Plaque volume and composition (non-calcified, calcified), remodeling index as well as contrast density difference (defined as the percentage decline in luminal CT attenuation/cross-sectional area over the lesion) were assessed using a semi-automatic software tool (Autoplaq). Additionally, the transluminal attenuation gradient (defined as the linear regression coefficient between intraluminal CT attenuation and length from the ostium) was determined

  7. Atrial fibrillation and acute myocardial infarction without significant coronary stenoses associated with subclinical hyperthyroidism and erythrocytosis.

    Science.gov (United States)

    Patanè, Salvatore; Marte, Filippo

    2010-11-05

    Subclinical hyperthyroidism is an increasingly recognized entity that is defined as a normal serum free thyroxine and free triiodothyronine levels with a thyroid-stimulating hormone level suppressed below the normal range and usually undetectable. It has been reported that sub-clinical hyperthyroidism is not associated with CHD or mortality from cardiovascular causes but is sufficient to induce arrhythmias including atrial fibrillation and atrial flutter. Moreover increased factor X activity in patients with subclinical hyperthyroidism represents a potential hypercoagulable state. It has been also reported an acute myocardial infarction with normal coronary arteries associated with iatrogenic hyperthyroidism and with a myocardial bridge too. It has been also reported an acute myocardial infarction without significant coronary stenoses associated with subclinical hyperthyroidism. Furthermore it has been reported that at highly increased hematocrit levels patients may experience hyperviscosity symptoms. We present a case of atrial fibrillation and acute myocardial infarction without significant coronary stenoses associated with subclinical hyperthyroidism and erythrocytosis. Also this case focuses attention on the importance of a correct evaluation of subclinical hyperthyroidism. Copyright © 2008 Elsevier Ireland Ltd. All rights reserved.

  8. Acute myocardial infarction without significant coronary stenoses associated with endogenous subclinical hyperthyroidism.

    Science.gov (United States)

    Patanè, Salvatore; Marte, Filippo; Sturiale, Mauro

    2012-04-05

    Subclinical hyperthyroidism is an increasingly recognized entity that is defined as a normal serum free thyroxine and free triiodothyronine levels with a thyroid-stimulating hormone level suppressed below the normal range and usually undetectable. It has been reported that subclinical hyperthyroidism is not associated with coronary heart disease or mortality from cardiovascular causes but it is sufficient to induce arrhythmias including atrial fibrillation and atrial flutter. Nowadays, there is growing interest regarding endogenous sublinical hyperthyroidism and the cardiovascular system. We present a case of acute myocardial infarction without significant coronary stenoses in a 75-year-old Italian woman with endogenous subclinical hyperthyroidism. Also this case focuses attention on the importance of a correct evaluation of endogenous subclinical hyperthyroidism. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  9. Influence of Microcirculatory Dysfunction on Angiography-Based Functional Assessment of Coronary Stenoses.

    Science.gov (United States)

    Mejía-Rentería, Hernán; Lee, Joo Myung; Lauri, Francesco; van der Hoeven, Nina W; de Waard, Guus A; Macaya, Fernando; Pérez-Vizcayno, María José; Gonzalo, Nieves; Jiménez-Quevedo, Pilar; Nombela-Franco, Luis; Salinas, Pablo; Núñez-Gil, Iván; Del Trigo, María; Goto, Sonoka; Lee, Hyun Jong; Liontou, Catherine; Fernández-Ortiz, Antonio; Macaya, Carlos; van Royen, Niels; Koo, Bon-Kwon; Escaned, Javier

    2018-04-23

    The authors sought to evaluate the influence of coronary microcirculatory dysfunction (CMD) on the diagnostic performance of the quantitative flow ratio (QFR). Functional angiographic assessment of coronary stenoses based on fluid dynamics, such as QFR, constitutes an attractive alternative to fractional flow reserve (FFR). However, it is unknown whether CMD affects the reliability of angiography-based functional indices. FFR and the index of microcirculatory resistance (IMR) were measured in 300 vessels (248 patients) as part of a multicenter international registry. QFR was calculated at a blinded core laboratory. Vessels were classified into 2 groups according to microcirculatory status: low IMR (<23 U), and high IMR (≥23 U, CMD). The impact of CMD on the diagnostic performance of QFR, as well as on incremental value of QFR over quantitative angiography, was assessed using FFR as reference. Percent diameter stenosis (%DS) and FFR were similar in low- and high-IMR groups (%DS 51 ± 12% vs. 53 ± 11%; p = 0.16; FFR 0.80 ± 0.11 vs. 0.81 ± 0.11; p = 0.23, respectively). In the overall cohort, classification agreement (CA) between QFR and FFR and diagnostic efficiency of QFR (area under the receiver-operating characteristics curve [AUC]) were high (CA: 88%; AUC: 0.93 [95% confidence interval (CI): 0.90 to 0.96]). However, when assessed according to microcirculatory status, a significantly lower CA and AUC of QFR were found in the high-IMR group as compared with the low-IMR group (CA: 76% vs. 92%; p < 0.001; AUC: 0.88 [95% CI: 0.79 to 0.94] vs. 0.96 [95% CI: 0.92 to 0.98]; p < 0.05). Compared with angiographic assessment, QFR increased by 0.20 (p < 0.001) and by 0.16 (p < 0.001) the AUC of %DS in low- and high-IMR groups, respectively. Independent predictors of misclassification between QFR and FFR were high IMR and acute coronary syndrome. CMD decreases the diagnostic performance of QFR. However, even in the presence of CMD, QFR remains superior to

  10. Normal stress-only myocardial single photon emission computed tomography predicts good outcome in patients with coronary artery stenoses between 40 and 70.

    Science.gov (United States)

    Jiang, Zhixin; Liu, Yangqing; Xin, Chaofan; Zhou, Yanli; Wang, Cheng; Zhao, Zhongqiang; Li, Chunxiang; Li, Dianfu

    2016-09-01

    Normal stress myocardial single photon emission computed tomography (SPECT) usually indicates good physiologic function of all coronary lesions, and also indicates a good outcome. We hypothesize that it can still predict good outcome in patients with coronary stenoses between 40 and 70%. A group of patients who underwent stress myocardial SPECT after coronary angiography were consecutively recruited in our center. Patients were eligible if they had one or more coronary stenoses between 40 and 70%. Patients with coronary stenoses greater than 50% diameter of left main or greater than 70% diameter of nonleft main epicardial vessels, and left ventricular ejection fraction less than 50% were excluded. The outcome was defined as major adverse events, including cardiac death, nonfatal myocardial infarction, and revascularization. Patients' survival curves were constructed accorded to the method of Kaplan and Meier and compared using the log-rank test. A study cohort of 77 patients was enrolled. According to the summed stress score, 43 patients were assigned to the perfusion defect group and 34 patients were assigned to the perfusion normal group. The follow-up duration was 6.4±0.3 years. In the perfusion normal group, only one of 34 (2.9%) patients developed major adverse events. In the perfusion defect group, six of 43 (14%) developed major adverse events, P-value of 0.041. It is safe to defer a percutaneous coronary intervention in patients with coronary stenoses between 40 and 70% and normal stress myocardial SPECT.

  11. Quantification of coronary artery stenoses. Comparison of 64-slice and dual source CT angiography with cardiac catheterization

    International Nuclear Information System (INIS)

    Busch, Stephanie; Nikolaou, K.; Johnson, T.; Rist, C.; Knez, A.; Reiser, M.; Becker, C.

    2007-01-01

    Until now stenoses of the coronary arteries have been evaluated visually with CT angiography. Therefore, the results were highly dependent on subjective factors inherent in the examiner. New software tools for semiquantitative analysis (CT-QCA, quantitative coronary assessment) might be adequate to improve the diagnostic accuracy und reproducibility. CTAs of 20 patients were analyzed. Ten patients each were evaluated using 64-slice CT (64SCT) and dual source CT (DSCT) (Somatom Sensation 64 and Somatom Definition, Siemens Medical Solutions, Forchheim), respectively. Two radiologists independently evaluated the data visually and with the help of a software tool (Syngo Circulation, Siemens Medical Solutions, Forchheim). The results of the quantitative assessment of the invasive heart catheterization served as the reference standard. Sensitivity and specificity as well as the correlation coefficient, the systematic error, and the interobserver agreement (kappa) were determined. In each of both patient groups 12 stenoses were detected. For the detection of stenoses >75%, sensitivity and specificity for the visual evaluation using the 64SCT were 100% and 90%, and with the CT-QCA both were 100%. For the DSCT sensitivity and specificity were 100% for both the visual and semiautomated evaluation. The Bland-Altman plot of the results of the 64SCT showed an overestimation of 3.3% (±62.7%/56.2%) compared to the heart catheterization. The results of the DSCT exhibited an overestimation of 6.2% (±33.1%/19.8%). The interobserver agreement of the CT-QCA and the visual evaluation showed a kappa value of 0.75 and for DSCT of 1.0. The results showed a good correlation of grading stenosis between the software-assisted evaluation and the results of the coronary catheter angiography. The promising results of the DSCT are due to a superior temporal resolution compared to the 64SCT. Confirmation of these data by trials in larger patient collectives is warranted. (orig.) [de

  12. Noninvasive assessment of coronary stenoses by myocardial imaging during pharmacologic coronary vasodilation. VI. Detection of coronary artery disease in human beings with intravenous N-13 ammonia and positron computed tomography

    International Nuclear Information System (INIS)

    Schelbert, H.R.; Wisenberg, G.; Phelps, M.E.; Gould, K.L.; Henze, E.; Hoffman, E.J.; Gomes, A.; Kuhl, D.E.

    1982-01-01

    The possibility of detecting mild coronary stenoses with positron computed tomography and nitrogen (N-13) ammonia administered during pharmacologic coronary vasodilation was previously demonstrated in chronically instrumented dogs. The feasibility of using this technique in human beings and its sensitivity in determining the degree and extent of coronary artery disease were examined in 13 young normal healthy volunteers and 32 patients with angiographically documented coronary artery disease. N-13 ammonia was administered intravenously and its distribution in the left ventricular myocardium recorded at rest and during dipyridamole-induced coronary hyperemia. In the 13 volunteers, N-13 activity was homogeneous at rest and during hyperemia, whereas 31 of the 32 patients had regional defects on the hyperemic images not present during rest. All six patients with double, all 10 with triple and 15 of 16 patients with single vessel disease (97 percent) were correctly identified with the technique. Two vessel involvement was correctly identified in five of the six patients with double vessel disease and three vessel disease in six of 10 patients. Of all 58 coronary stenoses, 52 (90 percent) were correctly identified. In a subgroup of 11 patients, the technique was compared with exercise thallium-201 planar images, which were abnormal in 10 (91 percent) whereas N-13 images were abnormal in all 11. Of the 19 stenosed coronary arteries in this subgroup, 11 (58 percent) were correctly identified with thallium-201 and 17 (89 percent) with tomography (p less than 0.01). It is concluded that cross-sectional imaging of the myocardial distribution of N-13 ammonia administered during pharmacologic coronary vasodilation is a highly sensitive and accurate means for noninvasive detection of coronary stenoses in human beings and for estimating the extent of coronary artery disease

  13. Stenosing tenosynovitis

    OpenAIRE

    Vuillemin, V.; Guerini, H.; Bard, H.; Morvan, G.

    2012-01-01

    Tenosynovitis refers to an inflammatory condition involving the synovial sheath of a tendon. Stenosing tenosynovitis is a peculiar entity caused by multiple factors, including local anatomy, mechanical factors, and hormonal factors. The main forms include de Quervain tendinopathy; trigger finger (stenosing tenosynovitis involving the flexor digitorum tendons); stenosing tenosynovitis of the extensor carpi ulnaris, extensor carpi radialis, or extensor comunis tendons; stenosing tenosynovitis o...

  14. Assessment of hemodynamic significance of isolated stenoses of the left anterior descending coronary artery using thallium-201 myocardial scintigraphy

    International Nuclear Information System (INIS)

    Kalff, V.; Kelly, M.J.; Soward, A.; Harper, R.W.; Currie, P.J.; Lim, Y.L.; Pitt, A.

    1985-01-01

    This study tests the hypothesis that the results of stress thallium-201 myocardial perfusion scans (TI-201) are related to the mean transstenotic pressure gradient of coronary stenoses independent of the percent luminal diameter narrowing seen at angiography. The 22 study patients (20 men, 2 women, mean age 47 years, range 30 to 62) had no previous myocardial infarction. Each underwent a symptom-limited, erect bicycle TI-201 test off antianginal therapy, shortly before percutaneous transluminal coronary angioplasty for isolated left anterior descending coronary artery stenosis. The percent narrowing, mean gradient at percutaneous transluminal coronary angioplasty and presence of a visually apparent TI-201 defect were independently evaluated and results compared. All 4 patients with 90% or greater diameter narrowing had positive TI-201 responses, and the mean gradient was 72 +/- 11 mm Hg. Among the 18 patients with less than 90% diameter narrowing, the mean gradient was higher (p less than 0.001) in the 11 with a positive TI-201 (63 +/- 15 mm Hg) than in the 7 with a negative TI-201 (33 +/- 20 mm Hg), but their percent narrowing did not differ significantly (72 +/- 14% vs 66 +/- 19%). Multiple regression analysis showed that the presence of a TI-201 defect was a strong (p . 0.003) and percent narrowing (p . 0.048) a weak independent predictor for gradient. When the mean gradient was normalized for the prestenotic pressure, both percent narrowing (p . 0.003) and TI-201 defects (p . 0.006) were significant independent predictors

  15. The value of regional wall motion abnormalities on 99Tcm-MIBI gated cardiac SPECT in predicting angiographic stenoses of coronary artery

    International Nuclear Information System (INIS)

    Li Dianfu; Huang Jun; Zhu Tiebing; Wang Liansheng; Yang Zhijian; Feng Jianlin; Li Jianhua; Chen Jianwei; Chang Guojun

    2004-01-01

    Objective: To determine the magnitude of angiographic stenoses of coronary artery in reversible regional wall motion abnormalities (RWMA) present in exercise stress 99 Tc m -methoxyisobutylisonitrile (MIBI) gated SPECT myocardial perfusion imaging (MPI). Methods: One hundred and sixteen patients undergoing coronary angiography two weeks before and after the exercise stress 99 Tc m -MIBI gated SPECT MPI. Images were acquired 15 to 20 min after stress. A five grades and twenty segments marking system was introduced to assess the RWMA and thickening of left ventricles. Results: The sensitivity of reversible RWMA for detecting ≥75% angiographic stenoses was 65%, with a specificity of 97%. Reversible RWMA has a high positive predictive value (98%) for stratification between severe angiographic stenoses of 75% and non-severe stenoses (less than 75%). Multivariate analysis showed that the post-stress wall motion (SSSWM), exercise wall motion differentiation value (SDSWM) and summed stress score (SSS) were the independent risk factor of coronary artery jeopardy score. Conclusions: Reversible RWMA, as shown by exercise stress 99 Tc m -MIBI gated SPECT MPI, is a significant predictor of angiographic disease with very high specificity and positive predictive values. Exercise reversible RWMA can rise the assessment value of angiographic severity in MPI

  16. 3D reconstruction of coronary arteries from 2D angiographic projections using non-uniform rational basis splines (NURBS for accurate modelling of coronary stenoses.

    Directory of Open Access Journals (Sweden)

    Francesca Galassi

    Full Text Available Assessment of coronary stenosis severity is crucial in clinical practice. This study proposes a novel method to generate 3D models of stenotic coronary arteries, directly from 2D coronary images, and suitable for immediate assessment of the stenosis severity.From multiple 2D X-ray coronary arteriogram projections, 2D vessels were extracted. A 3D centreline was reconstructed as intersection of surfaces from corresponding branches. Next, 3D luminal contours were generated in a two-step process: first, a Non-Uniform Rational B-Spline (NURBS circular contour was designed and, second, its control points were adjusted to interpolate computed 3D boundary points. Finally, a 3D surface was generated as an interpolation across the control points of the contours and used in the analysis of the severity of a lesion. To evaluate the method, we compared 3D reconstructed lesions with Optical Coherence Tomography (OCT, an invasive imaging modality that enables high-resolution endoluminal visualization of lesion anatomy.Validation was performed on routine clinical data. Analysis of paired cross-sectional area discrepancies indicated that the proposed method more closely represented OCT contours than conventional approaches in luminal surface reconstruction, with overall root-mean-square errors ranging from 0.213mm2 to 1.013mm2, and maximum error of 1.837mm2. Comparison of volume reduction due to a lesion with corresponding FFR measurement suggests that the method may help in estimating the physiological significance of a lesion.The algorithm accurately reconstructed 3D models of lesioned arteries and enabled quantitative assessment of stenoses. The proposed method has the potential to allow immediate analysis of the stenoses in clinical practice, thereby providing incremental diagnostic and prognostic information to guide treatments in real time and without the need for invasive techniques.

  17. Electrical neuromodulation for disabling angina pectoris related to isolated stenoses of small epicardial coronary arteries

    NARCIS (Netherlands)

    Jessurun, GAJ; Hautvast, RWM; DeJongste, MJL; Meyler, WJ; van Boven, AJ; Crijns, HJGM

    Patients with symptomatic small vessel coronary artery disease may be inadequate candidates for revascularization procedures. They may suffer from refractory angina, which does not respond to maximal anti-anginal drug therapy. In addition to patients with end stage coronary artery disease and

  18. Effect of stenosed and occluded coronary arteries on immediate and late myocardial uptake of thallium-201.

    Science.gov (United States)

    Clitsakis, D; Layton, C A; Battersby, W; Johns, M; Stockley, A V

    1981-01-01

    Exercise and redistribution myocardial scintigraphy using thallium-201 was compared with the left ventricular angiogram and with the presence of stenosis or occlusion of coronary arteries on angiography. Irreversible scintigraphic defects representing areas of myocardial infarction were found in all patients with occlusion of the left anterior descending artery but nearly one-third of patients with stenosis of that artery also showed evidence of infarction. For the right coronary or circumflex arteries the incidence of infarction was 82% with vessel occlusion and 57% with vessel stenosis. Of abnormally contracting segments on the left ventricular angiogram, 95% showed irreversible scintigraphic defects but 33% of normally contracting segments supplied by a diseased artery also showed this. Myocardial infarction is not uncommon in patients with angina even in the absence of coronary occlusion. The incidence is underestimated by the left ventricular angiogram. These findings are of importance in the assessment of patients with coronary disease and their evaluation before coronary artery surgery. PMID:7272129

  19. Effect of porous media of the stenosed artery wall to the coronary physiological diagnostic parameter: a computational fluid dynamic analysis.

    Science.gov (United States)

    Govindaraju, Kalimuthu; Kamangar, Sarfaraz; Badruddin, Irfan Anjum; Viswanathan, Girish N; Badarudin, A; Salman Ahmed, N J

    2014-04-01

    Functional assessment of a coronary artery stenosis severity is generally assessed by fractional flow reserve (FFR), which is calculated from pressure measurements across the stenosis. The purpose of this study is to investigate the effect of porous media of the stenosed arterial wall on this diagnostic parameter. To understand the role of porous media on the diagnostic parameter FFR, a 3D computational simulations of the blood flow in rigid and porous stenotic artery wall models are carried out under steady state and transient conditions for three different percentage area stenoses (AS) corresponding to 70% (moderate), 80% (intermediate), and 90% (severe). Blood was modeled as a non Newtonian fluid. The variations of pressure drop across the stenosis and diagnostic parameter were studied in both models. The FFR decreased in proportion to the increase in the severity of the stenosis. The relationship between the percentage AS and the FFR was non linear and inversely related in both the models. The cut-off value of 0.75 for FFR was observed at 81.89% AS for the rigid artery model whereas 83.61% AS for the porous artery wall model. This study demonstrates that the porous media consideration on the stenotic arterial wall plays a substantial role in defining the cut-off value of FFR. We conclude that the effect of porous media on FFR, could lead to misinterpretation of the functional severity of the stenosis in the region of 81.89 %-83.61% AS. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  20. Electrical neuromodulation for disabling angina pectoris related to isolated stenoses of small epicardial coronary arteries.

    Science.gov (United States)

    Jessurun, G A; Hautvast, R W; DeJongste, M J; Meyler, W J; van Boven AJ; Crijns, H J

    1999-07-01

    Patients with symptomatic small vessel coronary artery disease may be inadequate candidates for revascularization procedures. They may suffer from refractory angina, which does not respond to maximal anti-anginal drug therapy. In addition to patients with end stage coronary artery disease and syndrome X, this newly defined group of subjects with an isolated stenosis of a small coronary artery may benefit from electrical neurostimulation. We describe two patients with intractable angina caused by a significant narrowing of a diagonal branch. This treatment modality should be considered as an alternative method for unsatisfactory revascularization procedures.

  1. The value of regional wall motion abnormalities on gated mycardiac perfusion imaging in perfusion imaging in predicting angiographic stenoses of coronary artery

    International Nuclear Information System (INIS)

    Yao Lixin; Liu Binbin

    2007-01-01

    Objective: To determine the possible level of angiographic stenoses of coronary artery at which reversible regional wall motion abnormalities (RWMA) are present on 99m Tc-sestamibi ( 99m Tc-MIBI)-gated myocardial perfusion imaging (MPI). Methods: ninty patients undergoing coronary angiography MPI within two weeks were recruited. A five grades and nine segments marking system was introduced to assess the RWMA and thickening of left ventricles. Results: The sensitivity of reversible RWMA for detecting ≥75% angiographic stenoses was 64%,with a specificity of 95% and positive predictive value of 97%. The presence of reversible RWMA was able to stratify patients with severe angiographic stenoses of 75% or more from those less than 75% with high positive predictive value. A good correlation was noted between the presence of reversible RWMA and the coronary artery jeopardy score. Multivariate analysis showed that the post-stress RWMA and reversible RWMA scores and positive dipyridamole-stress exercise electrocardiogram(ECG) were significant predictors of angiographic severity. Conclusions: Reversible RWMA, as shown by dipyridamole stress 99m Tc-MIBI MPI, is a significant predictor of angiographic disease with very high specificity and adds incremental value to MPI for the assessment of angiographic severity. (authors)

  2. Multislice computed tomography: angiographic emulation versus standard assessment for detection of coronary stenoses

    Energy Technology Data Exchange (ETDEWEB)

    Schnapauff, Dirk; Hamm, Bernd; Dewey, Marc [Humboldt-Universitaet zu Berlin, Department of Radiology, Charite - Universitaetsmedizin Berlin, Chariteplatz 1, P.O. Box 10098, Berlin (Germany); Duebel, Hans-Peter; Baumann, Gert [Charite - Universitaetsmedizin Berlin, Department of Cardiology, Berlin (Germany); Scholze, Juergen [Charite - Universitaetsmedizin Berlin, Charite Outpatient Centre, Berlin (Germany)

    2007-07-15

    The present study investigated angiographic emulation of multislice computed tomography (MSCT) (catheter-like visualization) as an alternative approach of analyzing and visualizing findings in comparison with standard assessment. Thirty patients (120 coronary arteries) were randomly selected from 90 prospectively investigated patients with suspected coronary artery disease who underwent MSCT (16-slice scanner, 0.5 mm collimation, 400 ms rotation time) prior to conventional coronary angiography for comparison of both approaches. Sensitivity and specificity of angiographic emulation [81% (26/32) and 93% (82/88)] were not significantly different from those of standard assessment [88% (28/32) and 99% (87/88)], while the per-case analysis time was significantly shorter for angiographic emulation than for standard assessment (3.4 {+-} 1.5 vs 7.0 {+-} 2.5 min, P < 0.001). Both interventional and referring cardiologists preferred angiographic emulation over standard curved multiplanar reformations of MSCT coronary angiography for illustration, mainly because of improved overall lucidity and depiction of sidebranches (P < 0.001). In conclusion, angiographic emulation of MSCT reduces analysis time, yields a diagnostic accuracy comparable to that of standard assessment, and is preferred by cardiologists for visualization of results. (orig.)

  3. Multidetector CT of the coronary imaging: assessment of image quality and accuracy in detecting stenoses

    International Nuclear Information System (INIS)

    Huang Meiping; Liu Qishun; Liu Hui; Liang Changhong; Zhang Shaobin

    2006-01-01

    Objective: To evaluate the image quality of 64-multi detector computed tomography (MDCT) and the clinical accuracy in detecting coronary artery lesions. Methods: One hundred and five patients were studied by MDCT. The results were compared with invasive coronary angiography (ICA). Patients were excluded for atrial fibrillation, but not for high heart rate, coronary calcification, or obesity. MDCT was analyzed with regard to image quality and presence of coronary artery lesions. Results: The data evaluation of the image quality was based on a total of 1365 segments (13 coronary segments for each patient), of which 1144 segments were considered to have diagnostic image quality, but 221 segments (16.2%) could not be sufficiently evaluated because of severe calcifications (153 segments) and motion artifacts (68 segments). The median calcium score [Agatston score equivalent (ASE)] was 154 (range 0--1983). 87 of the 105 patients had an ASE of less than 1,000 [median 105 (range 0-994)], and 18 patients had an ASE greater than 1000 [median 1477 (range 1115-1983)]. For detecting lesions with 50% or greater narrowing (without any exclusion criteria), the overall sensitivity, specificity, positive predictive value, and negative predictive value were 85.7%, 97.9%, 93.0%, and 95.5%, respectively. When limiting the number of patients to those with a calcium score of less than 1000 ASE, the threshold- corrected sensitivity for lesions with 50% or greater narrowing was 96.0%; specificity, 98.9%; positive predictive value, 95.3%; and negative predictive value, 99.0%. Conclusion: Our results indicate high quantitative and qualitative diagnostic accuracy of 64-slice MSCT in comparison to QCA in a broad spectrum of patients. (authors)

  4. Validation of the "smart" minimum FFR Algorithm in an unselected all comer population of patients with intermediate coronary stenoses.

    Science.gov (United States)

    Hennigan, Barry; Johnson, Nils; McClure, John; Corcoran, David; Watkins, Stuart; Berry, Colin; Oldroyd, Keith G

    2017-07-01

    Using data from a commercial pressure wire system (St. Jude Medical) we previously developed an automated "smart" algorithm to determine a reproducible value for minimum FFR (smFFR) and confirmed that it correlated very closely with measurements made off-line by experienced coronary physiology core laboratories. In this study we used the same "smart" minimum algorithm to analyze data derived from a different, commercial pressure wire system (Philips Volcano) and compared the values obtained to both operator-defined steady state FFR and the online automated minimum FFR reported by the pressure wire analyser. For this analysis, we used the data collected during the VERIFY 2 study (Hennigan et al. in Circ Cardiovasc Interv, doi: 10.1161/CIRCINTERVENTIONS.116.004016 ) in which we measured FFR in 257 intermediate coronary stenoses (mean DS 48%) in 197 patients. Maximal hyperaemia was induced using intravenous adenosine (140 mcg/kg/min). We recorded both the online minimum FFR generated by the analyser and the operator-reported steady state FFR. Subsequently, the raw pressure tracings were coded, anonymised and 256/257 were subjected to further off-line analysis using the smart minimum FFR (smFFR) algorithm. The operator-defined steady state FFR correlated well with smFFR: r = 0.988 (p 0.05 among methods were rare but in these cases the two automated algorithms almost always agreed with each other rather than with the operator-reported value. Within the VERIFY 2 dataset, experienced operators reported a similar FFR value to both an online automated minimum (Philips Volcano) and off-line "smart" minimum computer algorithm. Thus, treatment decisions and clinical studies using either method will produce nearly identical results.

  5. Sixty-four slice spiral CT angiography does not predict the functional relevance of coronary artery stenoses in patients with stable angina

    International Nuclear Information System (INIS)

    Hacker, Marcus; Hack, Nicolas; Hahn, Klaus; Tiling, Reinhold; Jakobs, Tobias; Nikolaou, Konstantin; Becker, Christoph; Reiser, Maximilian; Ziegler, Franz von; Knez, Andreas; Koenig, Andreas; Klauss, Volker

    2007-01-01

    The aim of this study was to evaluate spiral multidetector computed tomography (MDCT) angiography using 64-slice technique in the detection of functionally relevant coronary artery stenoses (CAS). Thirty-eight patients (62±11 years, 28 men) with stable angina (26 with suspected and 12 with known coronary artery disease) were investigated using 64-slice MDCT angiography and gated myocardial perfusion SPECT (gated SPECT); a subgroup of 30 patients had additional invasive coronary angiography (ICA). Stenoses with luminal narrowing of ≥50% were defined as ''significant'' in MDCT angiography and ICA. MDCT angiography was compared with gated SPECT and the combination of gated SPECT plus ICA with respect to the detection of functionally relevant CAS. The sensitivity, specificity and negative and positive predictive values of MDCT angiography in detecting reversible perfusion defects on gated SPECT were 63%, 80%, 94% and 32%, respectively, in vessel-based analysis and 71%, 62%, 72% and 60%, respectively, in patient-based analysis. If only reversible perfusion defects on gated SPECT with CAS ≥50% on ICA were considered, the sensitivity, specificity and negative and positive predictive values were, respectively, 85%, 79%, 98% and 33% for vessel-based analysis and 85%, 59%, 83% and 61% for patient-based analysis. Sixty-four slice MDCT angiography failed to predict the functional relevance of CAS, but had a high negative predictive value in the exclusion of functionally relevant CAS in symptomatic patients. (orig.)

  6. Sixty-four slice spiral CT angiography does not predict the functional relevance of coronary artery stenoses in patients with stable angina

    Energy Technology Data Exchange (ETDEWEB)

    Hacker, Marcus; Hack, Nicolas; Hahn, Klaus; Tiling, Reinhold [Ludwig-Maximilians-University, Department of Nuclear Medicine, Munich (Germany); Jakobs, Tobias; Nikolaou, Konstantin; Becker, Christoph; Reiser, Maximilian [Ludwig-Maximilians-University, Department of Clinical Radiology, Munich (Germany); Ziegler, Franz von; Knez, Andreas [Ludwig-Maximilians-University, Department of Cardiology, Klinikum Grosshadern, Munich (Germany); Koenig, Andreas; Klauss, Volker [Ludwig-Maximilians-University, Department of Cardiology, Medizinische Poliklinik-Innenstadt, Munich (Germany)

    2007-01-15

    The aim of this study was to evaluate spiral multidetector computed tomography (MDCT) angiography using 64-slice technique in the detection of functionally relevant coronary artery stenoses (CAS). Thirty-eight patients (62{+-}11 years, 28 men) with stable angina (26 with suspected and 12 with known coronary artery disease) were investigated using 64-slice MDCT angiography and gated myocardial perfusion SPECT (gated SPECT); a subgroup of 30 patients had additional invasive coronary angiography (ICA). Stenoses with luminal narrowing of {>=}50% were defined as ''significant'' in MDCT angiography and ICA. MDCT angiography was compared with gated SPECT and the combination of gated SPECT plus ICA with respect to the detection of functionally relevant CAS. The sensitivity, specificity and negative and positive predictive values of MDCT angiography in detecting reversible perfusion defects on gated SPECT were 63%, 80%, 94% and 32%, respectively, in vessel-based analysis and 71%, 62%, 72% and 60%, respectively, in patient-based analysis. If only reversible perfusion defects on gated SPECT with CAS {>=}50% on ICA were considered, the sensitivity, specificity and negative and positive predictive values were, respectively, 85%, 79%, 98% and 33% for vessel-based analysis and 85%, 59%, 83% and 61% for patient-based analysis. Sixty-four slice MDCT angiography failed to predict the functional relevance of CAS, but had a high negative predictive value in the exclusion of functionally relevant CAS in symptomatic patients. (orig.)

  7. Instantaneous wave-free ratio as an alternative to fractional flow reserve in assessment of moderate coronary stenoses: A meta-analysis of diagnostic accuracy studies.

    Science.gov (United States)

    Maini, Rohit; Moscona, John; Katigbak, Paul; Fernandez, Camilo; Sidhu, Gursukhmandeep; Saleh, Qusai; Irimpen, Anand; Samson, Rohan; LeJemtel, Thierry

    2017-12-27

    Fractional flow reserve (FFR) remains underutilized due to practical concerns related to the need for hyperemic agents. These concerns have prompted the study of instantaneous wave-free ratio (iFR), a vasodilator-free index of coronary stenosis. Non-inferior cardiovascular outcomes have been demonstrated in two recent randomized clinic trials. We performed this meta-analysis to provide a necessary update of the diagnostic accuracy of iFR referenced to FFR based on the addition of eight more recent studies and 3727 more lesions. We searched the PubMed, EMBASE, Central, ProQuest, and Web of Science databases for full text articles published through May 31, 2017 to identify studies addressing the diagnostic accuracy of iFR referenced to FFR≤0.80. The following keywords were used: "instantaneous wave-free ratio" OR "iFR" AND "fractional flow reserve" OR "FFR." In total, 16 studies comprising 5756 lesions were identified. Pooled diagnostic accuracy estimates of iFR versus FFR≤0.80 were: sensitivity, 0.78 (95% CI, 0.76-0.79); specificity, 0.83 (0.81-0.84); positive likelihood ratio, 4.54 (3.85-5.35); negative likelihood ratio, 0.28 (0.24-0.32); diagnostic odds ratio, 17.38 (14.16-21.34); area under the summary receiver-operating characteristic curve, 0.87; and an overall diagnostic accuracy of 0.81 (0.78-0.84). In conclusion, iFR showed excellent agreement with FFR as a resting index of coronary stenosis severity without the undesired effects and cost of hyperemic agents. When considering along with its clinical outcome data and ease of application, the diagnostic accuracy of iFR supports its use as a suitable alternative to FFR for physiology-guided revascularization of moderate coronary stenoses. We performed a meta-analysis of the diagnostic accuracy of iFR referenced to FFR. iFR showed excellent agreement with FFR as a resting index of coronary stenosis severity without the undesired effects and cost of hyperemic agents. This supports its use as a suitable

  8. Transmural myocardial perfusion gradients in relation to coronary artery stenoses severity assessed by cardiac multidetector computed tomography

    DEFF Research Database (Denmark)

    Linde, Jesper James; Kühl, Jørgen Tobias; Hove, Jens Dahlgaard

    2015-01-01

    To assess the relationship between epicardial coronary artery stenosis severity and the corresponding regional transmural perfusion at rest and during adenosine stress, using multidetector computed tomography (MDCT). We evaluated the relationship between the severity of coronary artery diameter...

  9. Influence of newly designed monorail pressure sensor catheter on coronary diagnostic parameters: an in vitro study.

    Science.gov (United States)

    Banerjee, Rupak K; Peelukhana, Srikara V; Goswami, Ishan

    2014-02-07

    The decision to perform intervention on a patient with coronary stenosis is often based on functional diagnostic parameters obtained from pressure and flow measurements using sensor-tipped guidewire at maximal vasodilation (hyperemia). Recently, a rapid exchange Monorail Pressure Sensor catheter of 0.022″ diameter (MPS22), with pressure sensor at distal end has been developed for improved assessment of stenosis severity. The hollow shaft of the MPS22 is designed to slide over any standard 0.014″ guidewire (G14). Hence, influence of MPS22 diameter on coronary diagnostic parameters needs investigation. An in vitro experiment was conducted to replicate physiologic flows in three representative area stenosis (AS): mild (64% AS), intermediate (80% AS), and severe (90% AS), for two arterial diameters, 3mm (N2; more common) and 2.5mm (N1). Influence of MPS22 on diagnostic parameters: fractional flow reserve (FFR) and pressure drop coefficient (CDP) was evaluated both at hyperemic and basal conditions, while comparing it with G14. The FFR values decreased for the MPS22 in comparison to G14, (Mild: 0.87 vs 0.88, Intermediate: 0.68 vs 0.73, Severe: 0.48 vs 0.56) and CDP values increased (Mild: 16 vs 14, Intermediate: 75 vs 56, Severe: 370 vs 182) for N2. Similar trend was observed in the case of N1. The FFR values were found to be well above (mild) and below (intermediate and severe) the diagnostic cut-off of 0.75. Therefore, MPS22 catheter can be used as a possible alternative to G14. Further, irrespective of the MPS22 or G14, basal FFR (FFRb) had overlapping ranges in close proximity for clinically relevant mild and intermediate stenoses that will lead to diagnostic uncertainty under both N1 and N2. However, CDPb had distinct ranges for different stenosis severities and could be a potential diagnostic parameter under basal conditions. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. In vitro evaluation of 56 coronary artery stents by 256-slice multi-detector coronary CT

    International Nuclear Information System (INIS)

    Steen, Henning; Andre, Florian; Korosoglou, Grigorios; Mueller, Dirk; Hosch, Waldemar; Kauczor, Hans-Ulrich; Giannitsis, Evangelos; Katus, Hugo A.

    2011-01-01

    Objective: We sought to investigate stent lumen visibility of 56 coronary stents with the newest 256-multi-slice-CT (256-MDCT) technology for different reconstruction algorithms in an in vitro model. Background: Early identification of in-stent restenosis (ISR) is important to avoid recurrent ischemia and prevent acute myocardial infarction (AMI). Since angiography has the disadvantage of high costs and its invasiveness, MDCT could be a convenient and safe non-invasive alternative for detection of ISR. Material and methods: Percentages of in-stent lumen diameter and in-stent signal attenuation (measured as contrast-to-noise ratio (CNR)) of 56 coronary stents (group A ≤2.5 mm; group B = 2.75-3.0 mm; group C = 3.5-4.0 mm) were evaluated in a coronary vessel in vitro phantom (iodine-filled plastic tubes) employing four different reconstruction algorithms (XCD, CC, CD, XCB) on a novel 256-MDCT (Philips-iCT, collimation = 128 mm x 0.625 mm; rotation time = 270 ms; tube current = 800 mA s with 120 kV). Analysis was conducted with the semi-automatical full-width-at-half-maximum (FWHM) method. P-values 60% for group C stents was significantly larger and CNR was significantly lower (both p 3.0 mm when analysed with cardio-dedicated sharp kernels, although clinical studies corroborating this claim should be performed. However, stents ≤3.0 mm reconstructed by soft kernels revealed insufficient in-stent lumen visualisation and should not be used in clinical practice. Further improvements in spatial and temporal image resolution as well as reductions of radiation exposure and image noise have to be accomplished for the ambitious goal of characterising both CT coronary artery anatomy and in-stent lumen.

  11. "DK Crush" Technique for a Tightly Stenosed Conjoined SVG Lesion in a Patient with Acute Coronary Syndrome and Cardiogenic Shock.

    Science.gov (United States)

    Chen, Kuan-Ju; Lee, Wen-Lieng; Liu, Tsun-Jui; Chang, Wei-Chun; Wang, Kuo-Yang; Su, Chieh-Shou

    2015-05-01

    Coronary artery bifurcation disease of saphenous venous graft (SVG) is extremely rare. SVG disease remains a challenging lesion to treat because of increased morbidity and mortality with repeated coronary artery bypass graft surgery (CABG), high rates of periprocedural complications, and in-stent restenosis or occlusion requiring repeat revascularization with percutaneous coronary intervention. Herein, we present the first reported case of using the "DK crush" technique to treat an inverted Y-shaped SVG bifurcation disease in a patient with a prior CABG and new-onset acute coronary syndrome. Arising from our treatment, favorable immediate and mid-term angiographic and clinical outcomes were obtained. Coronary artery bypass surgery (CABG); "DK crush" technique; Saphenous venous graft (SVG).

  12. Combined use of 64-slice computed tomography angiography and gated myocardial perfusion SPECT for the detection of functionally relevant coronary artery stenoses. First results in a clinical setting concerning patients with stable angina

    International Nuclear Information System (INIS)

    Hacker, M.; Hack, N.; Tiling, R.; Jakobs, T.; Nikolaou, K.; Becker, C.; Ziegler, F. von; Knez, A.; Koenig, A.; Klauss, V.

    2007-01-01

    Aim: In patients with stable angina pectoris both morphological and functional information about the coronary artery tree should be present before revascularization therapy is performed. High accuracy was shown for spiral computed tomography (MDCT) angiography acquired with a 64-slice CT scanner compared to invasive coronary angiography (ICA) in detecting obstructive'' coronary artery disease (CAD). Gated myocardial SPECT (MPI) is an established method for the noninvasive assessment of functional significance of coronary stenoses. Aim of the study was to evaluate the combination of 64-slice CT angiography plus MPI in comparison to ICA plus MPI in the detection of hemodynamically relevant coronary artery stenoses in a clinical setting. Patients, methods: 30 patients (63 ± 10.8 years, 23 men) with stable angina (21 with suspected, 9 with known CAD) were investigated. MPI, 64-slice CT angiography and ICA were performed, reversible and fixed perfusion defects were allocated to determining lesions separately for MDCT angiography and ICA. The combination of MDCT angiography plus MPI was compared to the results of ICA plus MPI. Results: Sensitivity, specificity, negative and positive predictive value for the combination of MDCT angiography plus MPI was 85%, 97%, 98% and 79%, respectively, on a vessel-based and 93%, 87%, 93% and 88%, respectively, on a patient-based level. 19 coronary arteries with stenoses =50% in both ICA and MDCT angiography showed no ischemia in MPI. Conclusion: The combination of 64-slice CT angiography and gated myocardial SPECT enabled a comprehensive non-invasive view of the anatomical and functional status of the coronary artery tree. (orig.)

  13. Combined use of 64-slice computed tomography angiography and gated myocardial perfusion SPECT for the detection of functionally relevant coronary artery stenoses. First results in a clinical setting concerning patients with stable angina

    Energy Technology Data Exchange (ETDEWEB)

    Hacker, M.; Hack, N.; Tiling, R. [Klinikum Grosshadern (Germany). Dept. of Nuclear Medicine; Jakobs, T.; Nikolaou, K.; Becker, C. [Klinikum Grosshadern (Germany). Dept. of Clinical Radiology; Ziegler, F. von; Knez, A. [Klinikum Grosshadern (Germany). Dept. of Cardiology; Koenig, A.; Klauss, V. [Medizinische Poliklinik-Innenstadt, Univ. of Munich (Germany). Dept. of Cardiology

    2007-07-01

    Aim: In patients with stable angina pectoris both morphological and functional information about the coronary artery tree should be present before revascularization therapy is performed. High accuracy was shown for spiral computed tomography (MDCT) angiography acquired with a 64-slice CT scanner compared to invasive coronary angiography (ICA) in detecting ''obstructive'' coronary artery disease (CAD). Gated myocardial SPECT (MPI) is an established method for the noninvasive assessment of functional significance of coronary stenoses. Aim of the study was to evaluate the combination of 64-slice CT angiography plus MPI in comparison to ICA plus MPI in the detection of hemodynamically relevant coronary artery stenoses in a clinical setting. Patients, methods: 30 patients (63 {+-} 10.8 years, 23 men) with stable angina (21 with suspected, 9 with known CAD) were investigated. MPI, 64-slice CT angiography and ICA were performed, reversible and fixed perfusion defects were allocated to determining lesions separately for MDCT angiography and ICA. The combination of MDCT angiography plus MPI was compared to the results of ICA plus MPI. Results: Sensitivity, specificity, negative and positive predictive value for the combination of MDCT angiography plus MPI was 85%, 97%, 98% and 79%, respectively, on a vessel-based and 93%, 87%, 93% and 88%, respectively, on a patient-based level. 19 coronary arteries with stenoses =50% in both ICA and MDCT angiography showed no ischemia in MPI. Conclusion: The combination of 64-slice CT angiography and gated myocardial SPECT enabled a comprehensive non-invasive view of the anatomical and functional status of the coronary artery tree. (orig.)

  14. Serial thallium-201 myocardial imaging after dipyridamole infusion: diagnostic utility in detecting coronary stenoses and relationship to regional wall motion

    International Nuclear Information System (INIS)

    Leppo, J.; Boucher, C.A.; Okada, R.D.; Newell, J.B.; Strauss, H.W.; Pohost, G.M.

    1982-01-01

    After a 4-minute i.v. dipyridamole infusion, 0.14 mg/kg/min, serial thallium-201 scans were obtained in 60 patients undergoing cardia catheterization. Forty patients had significant (greater than or equal to50% stenosis) coronary artery disease (CAD), and 20 patients had normal coronary arteries or trivial lesions. The images were graded qualitatively for thallium activity by three observers. Sensitivity was 93% (37 of 40) and specificity was 80% (16 of 20). The sensitivity and specificity of the thallium-201 study were not affected by the extent of CAD, the presence of Q waves, or propranolol therapy. Twenty-seven of 37 patients who had initial defects (73%) had complete thallium redistribution of one or more defects. Patient-by-patient anlaysis using a regression model of all patients showed that the fate of a segmental thallium defect predicted abnormal wall motion by angiography better than ECG Q waves. The presence of propranolol therapy or collaterals did not significantly affect the thallium redistribution results. It is concluded that qualitative interpretation by multiple observers of thallium images after dipyridamole infusion is a highly sensitive and specific test for CAD. After dipyridamole, as with exercise stress, the extent of thallium redistribution is related to the degree of myocardial wall motion abnormality

  15. Percutaneous angioplasty of carotid artery stenoses

    Energy Technology Data Exchange (ETDEWEB)

    Freitag, G.; Freitag, J.; Koch, R.D.; Wagemann, W.

    1986-03-01

    Percutaneous transluminal angioplasty (PTA) is a well-established method to remedy stenoses and short occlusions in the femoro-popliteal region and has also proved worthwhile in dilating stenoses of pelvic, renal and coronary arteries. Following successful experiments in animals, Mathias et al. employed angioplasty to treat carotid artery stenoses in the same way. To date, successful treatment of carotid artery stenoses has been described only in isolated recent reports. For fear of embolism, angioplasty has not yet become standard practice in this region. Because of the limited number of carotid artery stenoses treated so far, the risk involved cannot be reliably assessed. It is remarkable that no embolism has been reported for the greater number of dilated stenoses of the subclavian artery. Moreover, the report by Mathias et al. indicated that for 350 angioplasties of pelvifemoral arteries 1.1% embolisms occured after artery occlusions only, while no embolism was observed after stenoses. Having gained experience of applying PTA to the treatment of vascular obstructions of extremities, we have adopted this technique in the carotid area as well.

  16. Novel monorail infusion catheter for volumetric coronary blood flow measurement in humans: in vitro validation.

    Science.gov (United States)

    van 't Veer, Marcel; Adjedj, Julien; Wijnbergen, Inge; Tóth, Gabor G; Rutten, Marcel C M; Barbato, Emanuele; van Nunen, Lokien X; Pijls, Nico H J; De Bruyne, Bernard

    2016-08-20

    The aim of this study is to validate a novel monorail infusion catheter for thermodilution-based quantitative coronary flow measurements. Based on the principles of thermodilution, volumetric coronary flow can be determined from the flow rate of a continuous saline infusion, the temperature of saline when it enters the coronary artery, and the temperature of the blood mixed with the saline in the distal part of the coronary artery. In an in vitro set-up of the systemic and coronary circulation at body temperature, coronary flow values were varied from 50-300 ml/min in steps of 50 ml/min. At each coronary flow value, thermodilution-based measurements were performed at infusion rates of 15, 20, and 30 ml/min. Temperatures and pressures were simultaneously measured with a pressure/temperature sensor-tipped guidewire. Agreement of the calculated flow and the measured flow as well as repeatability were assessed. A total of five catheters were tested, with a total of 180 measurements. A strong correlation (ρ=0.976, p<0.0001) and a difference of -6.5±15.5 ml/min were found between measured and calculated flow. The difference between two repeated measures was 0.2%±8.0%. This novel infusion catheter used in combination with a pressure/temperature sensor-tipped guidewire allows accurate and repeatable absolute coronary flow measurements. This opens a window to a better understanding of the coronary microcirculation.

  17. Imaging of coronary artery stents using multislice computed tomography: in vitro evaluation

    International Nuclear Information System (INIS)

    Maintz, David; Juergens, Kai-Uwe; Heindel, Walter; Fischbach, Roman; Wichter, Thomas; Grude, Matthias

    2003-01-01

    The aim of this study was to evaluate imaging features of different coronary artery stents during multislice CT Angiography (MSCTA). Nineteen stents made of varying material (steel, nitinol, tantalum) and of varying stent design were implanted in plastic tubes with an inner diameter of 3 mm to simulate a coronary artery. The tubes were filled with iodinated contrast material diluted to 200 Hounsfield units (HU), closed at both ends and positioned in a plastic container filled with oil (-70 HU). The MSCT scans were obtained perpendicular to the stent axes (detector collimation 4 x 1 mm, table feed 2 mm/rotation, 300 mAs, 120 kV). Axial images and multiplanar reformations were evaluated regarding artifact size, lumen visibility, and intraluminal attenuation values. Artifacts characterized by artifactual thickening of the stent struts leading to apparent reduction in the lumen diameter and increased intraluminal attenuation values were observed in all cases. The stent lumen was totally obscured in the Wiktor stent, the Wallgraft stent, and the Nir Royal stent. Partial residual of the stent lumen could be visualized in all other utilized stent products (artificial lumen reductions ranged from 62% in the V-Flex stent to 94% in the Bx Velocity stent). Parts of the stent lumen can be visualized in most coronary artery stents; however, detectability of in-stent stenoses remains to be evaluated for each stent type. (orig.)

  18. The dependence of the seriousness of the ischaemic reaction in exercise ECGs and the left-ventricular disfunction determined by means of angiography on the extent of stenosing coronary sclerosis

    International Nuclear Information System (INIS)

    Apelbaum, J.

    1981-01-01

    The relations between the depression of the ST segment in exercise EC and the extent of an angiographically determined sclerosis of the coronary arteries with consideration of the normal vessel diameter are significant in 23 patients without myocardial infarction but with a disease of a single vessel. With increasing stenosis of a single blood vessel with large normal diameter the severity and expansion of the resulting ischaemic reaction in the exercise EGG also increases. The comparisons of the 75 diseases involving several vessels, however, showed only very loose relationships. It was found out in the group of patients after infarction that the size of the infarction region depends on the diameter of the stenosing blood vessel. Significant correlations were also revealed by comparisons to EDP, EF, the contraction-disturbed diastolic heart circumference, and the number of the changed leads of the resting ECG. The correlations with EDP were relatively insignificant. The resting ECG could be additionally correlated to the contraction-disturbed diastolic heart circumference, the EDP and EF. In all sections of this paper the correlations with stenoses in the region of ramus circumflexus were not as good. (orig./MG) [de

  19. Tibolone and its metabolites acutely relax rabbit coronary arteries in vitro

    DEFF Research Database (Denmark)

    Lund, Claus Otto; Nilas, Lisbeth; Pedersen, Susan Helene

    2004-01-01

    under curve (AUC). RESULTS: Tibolone and its metabolites induced a concentration-dependent vasodilatation comparable to that of 17 beta-estradiol with the rank of potency: 3 beta-OH-tibolone approximately = to tibolone>3 alpha-OH-tibolone>Delta 4-isomer (ANOVA). l-NAME partly inhibited the relaxation.......05, ANOVA). CONCLUSIONS: Our data indicate that the acute relaxation induced by tibolone and its metabolites in coronary arteries in vitro are probably mediated by endothelium independent inhibition of calcium channels but may also involve an endothelium-dependent mechanism via nitric oxide. The effect...

  20. 64-slice multidetector coronary CT angiography: in vitro evaluation of 68 different stents

    International Nuclear Information System (INIS)

    Maintz, David; Seifarth, Harald; Rink, Michael; Oezguen, Murat; Heindel, Walter; Fischbach, Roman; Raupach, Rainer; Flohr, Thomas; Sommer, Torsten

    2006-01-01

    The purpose of this study was to test a large sample of different coronary artery stents using four image reconstruction approaches with respect to lumen visualization, lumen attenuation, and image noise in 64-slice multidetector-row computed tomography (MDCT) in vitro and to provide a catalogue of currently used coronary artery stents when imaged with state-of the-art MDCT. We examined 68 different coronary artery stents (57 stainless steel, four cobalt-chromium, one cobalt-alloy, two nitinol, four tantalum) in a coronary artery phantom (vessel diameter 3 mm, intravascular attenuation 250 HU, extravascular density -70). Stents were imaged in axial orientation with standard parameters: 32x0.6 collimation, pitch 0.24, 680 mAs, 120 kV, rotation time 0.37 s. Four different image reconstructions were obtained with varying convolution kernels and section thicknesses: (1) soft, 0.6 mm, (2) soft, 0.75, (3) medium soft, 0.6, and (4) stent-optimized sharp, 0.6. To evaluate visualization characteristics of of the stent, the lumen diameter, intraluminal density and noise were measured. The high-resolution kernel offered significantly better average lumen visualization (57% ±10%) and more realistic lumen attenuation (222 HU ±66 HU) at the expense of increased noise (15.3 HU ±3.7 HU) compared with the soft and medium-soft CT angiography (CTA) protocol (p<0.001 for all). Stents with a lumen visibility of more than 66% were: Arthos pico, Driver, Flex, Nexus2, S7, Tenax complete, Vision (all 67%), Symbiot, Teneo (70%), and Radius (73%). Only ten stents showed a lumen visibility of less than 50%. Stent lumen visibility largely varies depending on the stent type. Even with the improved spatial resolution of 64-slice CT, a stent-optimized kernel remains beneficial for stent visualization when compared with the standard medium-soft CTA protocol. Using 64-slice CT and high-resolution kernel, the majority of stent products show a lumen visibility of more than 50% of the stent

  1. Endovascular treatment of renal artery stenoses

    International Nuclear Information System (INIS)

    Lashari, M.N.

    2015-01-01

    To evaluate the procedure success and effect on hypertension after stenting of incidentally diagnosed atherosclerotic renal artery stenoses. Study Design: An experimental study. Place and Duration of Study: A multicentric study was conducted at the Plastic Surgery and General Hospital, National Medical Center and Ziauddin University Hospital, Karachi, Pakistan from January 2009 to March 2013. Methodology: Hypertension (systolic blood pressure > 160 and diastolic > 90 mmHg with two or more than two medications) with coronary artery disease were initially evaluated for coronary angiography, Renal artery angiography was also endovascular performed and stent was deployed for atherosclerotic renal artery stenosis when found. Blood pressure readings, reduction in need of antihypertensive medication and serum creatinine levels were taken as outcome measures. Patients having renal artery stenoses secondary to connective tissue disorders and fibromuscular dysplasia were excluded. Results: There were 25 patients, 14 (56%) male and 11 (44%) female, with mean age of 49 +- 6 years. Diabetes mellitus, dyslipidemia and smoking were seen in 11 (44%), 10 (40%) and 4 (16%) patients respectively. Renal insufficiency (serum creatinine > 1.5 mg/dl) was seen in one (04%) patient. Bilateral, and isolated right and left renal artery stenoses was seen in 5 (20%), 9 (36%) and 11(44%) patients respectively. Mean percentage of renal artery stenoses was 89%, ranged from 70% to 99% while ostial lesion was found in 20 (80%) patients. A significant decrease in systolic (168.20 +- 9.987 vs. 140.60 +- 5.649 mmHg, p < 0.001) and diastolic blood pressure (88.60 +- 5.50 vs. 77.20 +- 5.017 mmHg, p < 0.001) and reduction of medication (2.72 +- 0.458 vs. 1.5 +- 0.510, p < 0.01) were noted without a change in renal function (p= 0.061) after renal artery stenting. Conclusion: Endovascular stenting of renal artery stenoses in patients with poorly controlled hypertension is a safe and effective treatment

  2. In-Vitro Evaluation of Coronary Stents and 64-Detector-Row Computed Tomography Using a Newly Developed Model of Coronary Artery Stenosis

    International Nuclear Information System (INIS)

    Schlosser, T.; Scheuermann, T.; Ulzheimer, S.; Mohrs, O.K.; Kuehling, M.; Al brecht, P.E.; Voigtlaender, T.; Barkhausen, J.; Schmermund, A.

    2008-01-01

    high-grade in-stent stenosis in vessels with a diameter of 3 to 4 mm. With regard to artifacts and the grading of stenoses, the Liberte stent was best suited for CT coronary angiography

  3. Novel monorail infusion catheter for volumetric coronary blood flow measurement in humans: in vitro validation

    NARCIS (Netherlands)

    van 't Veer, M.; Adjedj, J.; Wijnbergen, I.; Tóth, G.G.; Rutten, M.C.M.; Barbato, E.; van Nunen, L.X.; Pijls, N.H.J.; de Bruyne, B.

    2016-01-01

    AIMS: The aim of this study is to validate a novel monorail infusion catheter for thermodilution-based quantitative coronary flow measurements. METHODS AND RESULTS: Based on the principles of thermodilution, volumetric coronary flow can be determined from the flow rate of a continuous saline

  4. Continuous infusion thermodilution for assessment of coronary flow: Theoretical background and in vitro validation

    NARCIS (Netherlands)

    Veer, van 't M.; Geven, M.C.F.; Rutten, M.C.M.; Horst, van der A.; Aarnoudse, W.H.; Pijls, N.H.J.; Vosse, van de F.N.

    2009-01-01

    Direct volumetric assessment of coronary flow during cardiac catheterization has not been available so far. In the current study continuous infusion thermodilution, a method based on continuous infusion of saline into a selective coronary artery is evaluated. Theoretically, volumetric flow can be

  5. In vitro imaging of coronary artery stents: Are there differences between 16- and 64-slice CT scanners?

    International Nuclear Information System (INIS)

    Wolf, Florian; Feuchtner, Gudrun M.; Homolka, Peter; Langenberger, Herbert; Stadler, Alfred; Bader, Till R.; Weber, Michael; Lammer, Johannes; Loewe, Christian

    2008-01-01

    Purpose: To compare the performance of 64-slice with 16-slice CT scanners for the in vitro evaluation of coronary artery stents. Methods and materials: Twelve different coronary artery stents were placed in the drillings of a combined heart and chest phantom, which was scanned with a 16- and 64-slice CT scanner. Coronal reformations were evaluated for artificial lumen narrowing, intraluminal attenuation values, and false widening of the outer stent diameter as an indicator of artifacts outside the stent. Results: Mean artificial lumen narrowing was not significantly different between the 16- and 64-slice CT scanner (44% versus 39%; p = 0.408). The differences between the Hounsfield Units (HU) measurements inside and outside the stents were significantly lower (p = 0.001) with 64- compared to 16-slice CT. The standard deviation of the HU measurements inside the stents was significantly (p = 0.002) lower with 64- than with 16-slice CT. Artifacts outside the stents were not significantly different between the scanners (p = 0.866). Conclusion: Visualization of the in-stent lumen is improved with 64-slice CT when compared with 16-slice CT as quantified by significantly lesser intraluminal image noise and less artificial rise in intraluminal HU measurement, which is the most important parameter for the evaluation of stent patency in vivo

  6. Towards Additive Manufacture of Functional, Spline-Based Morphometric Models of Healthy and Diseased Coronary Arteries: In Vitro Proof-of-Concept Using a Porcine Template

    Directory of Open Access Journals (Sweden)

    Rachel Jewkes

    2018-02-01

    Full Text Available The aim of this study is to assess the additive manufacture of morphometric models of healthy and diseased coronary arteries. Using a dissected porcine coronary artery, a model was developed with the use of computer aided engineering, with splines used to design arteries in health and disease. The model was altered to demonstrate four cases of stenosis displaying varying severity, based on published morphometric data available. Both an Objet Eden 250 printer and a Solidscape 3Z Pro printer were used in this analysis. A wax printed model was set into a flexible thermoplastic and was valuable for experimental testing with helical flow patterns observed in healthy models, dominating the distal LAD (left anterior descending and left circumflex arteries. Recirculation zones were detected in all models, but were visibly larger in the stenosed cases. Resin models provide useful analytical tools for understanding the spatial relationships of blood vessels, and could be applied to preoperative planning techniques, but were not suitable for physical testing. In conclusion, it is feasible to develop blood vessel models enabling experimental work; further, through additive manufacture of bio-compatible materials, there is the possibility of manufacturing customized replacement arteries.

  7. Towards Additive Manufacture of Functional, Spline-Based Morphometric Models of Healthy and Diseased Coronary Arteries: In Vitro Proof-of-Concept Using a Porcine Template.

    Science.gov (United States)

    Jewkes, Rachel; Burton, Hanna E; Espino, Daniel M

    2018-02-02

    The aim of this study is to assess the additive manufacture of morphometric models of healthy and diseased coronary arteries. Using a dissected porcine coronary artery, a model was developed with the use of computer aided engineering, with splines used to design arteries in health and disease. The model was altered to demonstrate four cases of stenosis displaying varying severity, based on published morphometric data available. Both an Objet Eden 250 printer and a Solidscape 3Z Pro printer were used in this analysis. A wax printed model was set into a flexible thermoplastic and was valuable for experimental testing with helical flow patterns observed in healthy models, dominating the distal LAD (left anterior descending) and left circumflex arteries. Recirculation zones were detected in all models, but were visibly larger in the stenosed cases. Resin models provide useful analytical tools for understanding the spatial relationships of blood vessels, and could be applied to preoperative planning techniques, but were not suitable for physical testing. In conclusion, it is feasible to develop blood vessel models enabling experimental work; further, through additive manufacture of bio-compatible materials, there is the possibility of manufacturing customized replacement arteries.

  8. Comparative angiographic quantitative analysis of the immediate efficacy of coronary atherectomy with balloon angioplasty, stenting, and rotational ablation

    NARCIS (Netherlands)

    V.A.W.M. Umans (Victor); B.H. Strauss (Bradley); B.J.W.M. Rensing (Benno); P.P.T. de Jaegere (Peter); P.J. de Feyter (Pim); P.W.J.C. Serruys (Patrick)

    1991-01-01

    markdownabstractAbstract Interventional cardiology has branched in two directions: devices that primarily dilate coronary stenoses and those that debulk coronary tissue. Presently the optimum coronary intervention has not been found. While patients are awaiting randomized trials, a comparison

  9. One hundred and thirteen attempts at directional coronary atherectomy: the early and combined experience of two European centres using quantitative angiography to assess their results

    NARCIS (Netherlands)

    V.A.W.M. Umans (Victor); E. Haine; J. Renkin; P.J. de Feyter (Pim); W. Wijns (William); P.W.J.C. Serruys (Patrick)

    1992-01-01

    textabstractDirectional coronary atherectomy has been introduced as an alternative to conventional balloon angioplasty when treating coronary artery stenoses with complex lesion morphology. To determine the immediate efficacy of coronary atherectomy in patients with such lesions, the first 113

  10. Quantitative analysis of vasodilatory action of quercetin on intramural coronary resistance arteries of the rat in vitro.

    Directory of Open Access Journals (Sweden)

    Anna Monori-Kiss

    Full Text Available BACKGROUND: Dietary quercetin improves cardiovascular health, relaxes some vascular smooth muscle and has been demonstrated to serve as a substrate for the cyclooxygenase enzyme. AIMS: 1. To test quantitatively a potential direct vasodilatory effect on intramural coronary resistance artery segments, in different concentrations. 2. To scale vasorelaxation at different intraluminal pressure loads on such vessels of different size. 3. To test the potential role of prostanoids in vasodilatation induced by quercetin. METHODS: Coronary arterioles (70-240 µm were prepared from 24 rats and pressurized in PSS, using a pressure microangiometer. RESULTS: The spontaneous tone that developed at 50 mmHg was relaxed by quercetin in the 10(-9 moles/lit concentration (p<0.05, while 10(-5 moles/lit caused full relaxation. Significant relaxation was observed at all pressure levels (10-100 mmHg at 10(-7 moles/lit concentration of quercetin. The cyclooxygenase blocker indomethacin (10(-5 moles/lit induced no relaxation but contraction when physiological concentrations of quercetin were present in the tissue bath (p<0.02 with Anova, this contraction being more prominent in smaller vessels and in the higher pressure range (p<0.05, Pearson correlation. A further 2-8% contraction could be elicited by the NO blocker L-NAME (10(-4 moles/lit. CONCLUSION: These results demonstrate that circulating levels of quercetin (10(-7 moles/lit exhibit a substantial coronary vasodilatory effect. The extent of it is commeasurable with that of several other physiological mechanisms of coronary blood flow control. At least part of this relaxation is the result of an altered balance toward the production of endogenous vasodilatory prostanoids in the coronary arteriole wall.

  11. Idiopathic intracranial hypertension and transverse sinus stenoses

    DEFF Research Database (Denmark)

    Skyrman, Simon; Fytagoridis, Anders; Andresen, Morten

    2013-01-01

    An 18-year-old woman was diagnosed with idiopathic intracranial hypertension (IIH) and bilateral transverse sinus stenoses (TSS), after presenting with papilledema and decreased visual acuity. Lumbar puncture revealed an opening pressure of >60 cm H2O. MRI showed bilateral TSS believed to be asso...

  12. Efficacy of stent angioplasty for symptomatic stenoses of the proximal vertebral artery

    Energy Technology Data Exchange (ETDEWEB)

    Weber, W. [Department of Radiology and Neuroradiology, Alfried Krupp Hospital, Essen (Germany); Mayer, T.E. [Department of Neuroradiology, Klinikum Grosshadern, University of Munich (Germany); Henkes, H. [Department of Radiology and Neuroradiology, Alfried Krupp Hospital, Essen (Germany); Kis, B. [Department of Neurology, Alfried Krupp Hospital, Essen (Germany) and Department of Psychiatry and Psychotherapy, University of Duisburg-Essen, Virchow Street 174, D-45147 Essen (Germany)]. E-mail: bernhard.kis@uni-duisburg-essen.de; Hamann, G.F. [Department of Neurology, Klinikum Grosshadern, University of Munich (Germany); Holtmannspoetter, M. [Department of Neuroradiology, Klinikum Grosshadern, University of Munich (Germany); Brueckmann, H. [Department of Neuroradiology, Klinikum Grosshadern, University of Munich (Germany); Kuehne, D. [Department of Radiology and Neuroradiology, Alfried Krupp Hospital, Essen (Germany)

    2005-11-01

    Background: To evaluate the safety and efficacy of stent angioplasty in the treatment of symptomatic arteriosclerotic stenoses of the proximal vertebral artery (VA). Methods: Thirty-eight symptomatic stenoses of the vertebral origin were treated with flexible balloon-expandable coronary stents. Angiographic and clinical follow-up examinations were obtained in 26 patients at a mean of 11 months. Results: The immediate post-procedural angiographic results showed no residual stenosis in 33 vessels and mild residual stenoses in five vessels. Periprocedurally, there were two asymptomatic technical complications and one TIA. During follow-up re-stenosis could be detected in 10 cases (36%), and vessel occlusions in two patients. Two stents were broken. One of the restenosis caused a TIA within the follow-up period. Conclusions: Flexible balloon-expandable coronary stents proved to be save and effective in preventing vertebrobasilar stroke but were incapable to preserve the proximal vertebral artery lumen. For the VA origine an adequate stent, self-expanding, bioresorbable, or drug-eluting has to be found.

  13. Efficacy of stent angioplasty for symptomatic stenoses of the proximal vertebral artery

    International Nuclear Information System (INIS)

    Weber, W.; Mayer, T.E.; Henkes, H.; Kis, B.; Hamann, G.F.; Holtmannspoetter, M.; Brueckmann, H.; Kuehne, D.

    2005-01-01

    Background: To evaluate the safety and efficacy of stent angioplasty in the treatment of symptomatic arteriosclerotic stenoses of the proximal vertebral artery (VA). Methods: Thirty-eight symptomatic stenoses of the vertebral origin were treated with flexible balloon-expandable coronary stents. Angiographic and clinical follow-up examinations were obtained in 26 patients at a mean of 11 months. Results: The immediate post-procedural angiographic results showed no residual stenosis in 33 vessels and mild residual stenoses in five vessels. Periprocedurally, there were two asymptomatic technical complications and one TIA. During follow-up re-stenosis could be detected in 10 cases (36%), and vessel occlusions in two patients. Two stents were broken. One of the restenosis caused a TIA within the follow-up period. Conclusions: Flexible balloon-expandable coronary stents proved to be save and effective in preventing vertebrobasilar stroke but were incapable to preserve the proximal vertebral artery lumen. For the VA origine an adequate stent, self-expanding, bioresorbable, or drug-eluting has to be found

  14. The relationship between fractional flow reserve, platelet reactivity and platelet leukocyte complexes in stable coronary artery disease

    NARCIS (Netherlands)

    Sels, J.W.E.M.; Rutten, B.; Holten, van T.C.; Hillaert, M.A.K.; Waltenberger, J.; Pijls, N.H.J.; Pasterkamp, G.; Groot, de P.G.; Roest, M.

    2013-01-01

    Background: The presence of stenoses that significantly impair blood flow and cause myocardial ischemia negatively affects prognosis of patients with stable coronary artery disease. Altered platelet reactivity has been associated with impaired prognosis of stable coronary artery disease. Platelets

  15. Phantom-Calibrated versus Automatic Coronary Artery Mass Quantification with Multidetector-Row Computed Tomography: In Vitro and In Vivo Study

    Energy Technology Data Exchange (ETDEWEB)

    Serafin, Z.; Lasek, W.; Laskowska, K. (Dept. of Radiology and Diagnostic Imaging, Nicolaus Copernicus Univ., Collegium Medicum, Bydgoszcz (Poland))

    2008-11-15

    Background: Coronary artery calcium scoring is used as a method for cardiovascular risk stratification and monitoring of coronary heart disease. Automatic software-based calcium mass calculation has been proposed to improve the performance of the procedure. Purpose: To compare two algorithms of calcium mass measurement, automatic and phantom calibrated, with respect to correlation, measurement error, and accuracy in vitro and in vivo. Material and Methods: A cardiac phantom with calcium cylinder inserts was scanned with sequential non-overlapping collimation 4x2.5 mm, at 120 kV and 165 mAs. Fifty adults (37 men; mean age 46.2 years) were examined with the same settings using prospective electrocardiographic triggering to detect and quantify coronary artery calcifications. Calculations were performed with two methods: software-based automatic calcium mass measurement (ACM) and phantom-calibrated calcium mass measurement (CCM). Results: The total phantom calcium masses measured with ACM and CCM were 175.0+-13.8 mg and 163.0+-4.4 mg, respectively (P<0.0001), and ACM produced a higher mean error (4.5 vs. 3.2; P<0.05). Results of ACM and CCM were strongly correlated to each other (R=0.73-0.96; P<0.0001). Mean image noise in the patient study was 8.72+-1.68 HU. Results of patient calcium scoring with ACM and CCM were significantly different (median 70.3 mg and 59.7 mg, respectively; P<0.0001), with a mean systematic error of 17.5% (limit of agreement between 14.6% and 20.4%). The use of ACM resulted in an altered quartile classification for 14% of patients, as compared to CCM; all of these patients were classified into a higher category. Conclusion: Our data indicate that multidetector-row computed tomography coronary calcium mass determination based on dedicated phantom calibration shows lower measurement error than an automatic software-based calculation method. The tested automatic software does not yet seem to be a reliable option for calcium mass measurement

  16. Phantom-Calibrated versus Automatic Coronary Artery Mass Quantification with Multidetector-Row Computed Tomography: In Vitro and In Vivo Study

    International Nuclear Information System (INIS)

    Serafin, Z.; Lasek, W.; Laskowska, K.

    2008-01-01

    Background: Coronary artery calcium scoring is used as a method for cardiovascular risk stratification and monitoring of coronary heart disease. Automatic software-based calcium mass calculation has been proposed to improve the performance of the procedure. Purpose: To compare two algorithms of calcium mass measurement, automatic and phantom calibrated, with respect to correlation, measurement error, and accuracy in vitro and in vivo. Material and Methods: A cardiac phantom with calcium cylinder inserts was scanned with sequential non-overlapping collimation 4x2.5 mm, at 120 kV and 165 mAs. Fifty adults (37 men; mean age 46.2 years) were examined with the same settings using prospective electrocardiographic triggering to detect and quantify coronary artery calcifications. Calculations were performed with two methods: software-based automatic calcium mass measurement (ACM) and phantom-calibrated calcium mass measurement (CCM). Results: The total phantom calcium masses measured with ACM and CCM were 175.0±13.8 mg and 163.0±4.4 mg, respectively (P<0.0001), and ACM produced a higher mean error (4.5 vs. 3.2; P<0.05). Results of ACM and CCM were strongly correlated to each other (R=0.73-0.96; P<0.0001). Mean image noise in the patient study was 8.72±1.68 HU. Results of patient calcium scoring with ACM and CCM were significantly different (median 70.3 mg and 59.7 mg, respectively; P<0.0001), with a mean systematic error of 17.5% (limit of agreement between 14.6% and 20.4%). The use of ACM resulted in an altered quartile classification for 14% of patients, as compared to CCM; all of these patients were classified into a higher category. Conclusion: Our data indicate that multidetector-row computed tomography coronary calcium mass determination based on dedicated phantom calibration shows lower measurement error than an automatic software-based calculation method. The tested automatic software does not yet seem to be a reliable option for calcium mass measurement

  17. Effects of abciximab on key pattern of human coronary restenosis in vitro: impact of the SI/MPL-ratio

    Directory of Open Access Journals (Sweden)

    Baur Regine

    2006-04-01

    Full Text Available Abstract Background The significant reduction of angiographic restenosis rates in the ISAR-SWEET study (intracoronary stenting and antithrombotic regimen: is abciximab a superior way to eliminate elevated thrombotic risk in diabetes raises the question of whether abciximab acts on clopidogrel-independent mechanisms in suppressing neointimal hyperplasia. The current study investigates the direct effect of abciximab on ICAM-1 expression, migration and proliferation. Methods ICAM-1: Part I of the study investigates in cytoflow studies the effect of abciximab (0.0002, 0.002, 0.02, 0.2, 2.0, and 20.0 μg/ml on TNF-α induced expression of intercellular adhesion molecule 1 (ICAM-1. Migration: Part II of the study explored the effect of abciximab (0.0002, 0.002, 0.02, 0.2, 2.0, and 20.0 μg/ml on migration of HCMSMC over a period of 24 h. Proliferation: Part III of the study investigated the effect of abciximab (0.0002, 0.002, 0.02, 0.2, 2.0, and 20.0 μg/ml on proliferation of HUVEC, HCAEC, and HCMSMC after an incubation period of 5 days. Results ICAM-1: In human venous endothelial cells (HUVEC, human coronary endothelial cells (HCAEC and human coronary medial smooth muscle cells (HCMSMC no inhibitory or stimulatory effect on expression of ICAM-1 was detected. Migration: After incubation of HCMSMC with abciximab in concentrations of 0.0002 – 2 μg/ml a stimulatory effect on cell migration was detected, statistical significance was achieved after incubation with 0.002 μg/ml (p 1. Conclusion Thus, the anti-restenotic effects of systemically administered abciximab reported in the ISAR-SWEET-study were not caused by a direct inhibitory effect on ICAM-1 expression, migration or proliferation.

  18. CT coronary angiography vs. invasive coronary angiography in CHD

    Directory of Open Access Journals (Sweden)

    Anja Hagen

    2012-04-01

    stenoses and two diagnostic studies using intracoronary pressure measurement as the reference standard (identification of functionally relevant stenoses were included in the medical evaluation. Meta-analysis of the nine studies of higher methodological quality showed that, CT coronary angiography with invasive coronary angiography as the reference standard, had a sensitivity of 96 % (95 % CI: 93 % to 98 %, specificity of 86 % (95 % CI: 83 % to 89 %, positive likelihood ratio of 6.38 (95 % CI: 5.18 to 7.87 and negative likelihood ratio of 0.06 (95 % CI: 0.03 to 0.10. However, due to non-diagnostic CT images approximately 3.6 % of the examined patients required a subsequent invasive coronary angiography. Using intracoronary pressure measurement as the reference standard, CT coronary angiography compared to invasive coronary angiography had a sensitivity of 80 % (95 % CI: 61 % to 92 % versus 67 % (95 % CI: 51 % to 78 %, a specificity of 67 % (95 % CI: 47 % to 83 % versus 75 % (95 % CI: 60 % to 86 %, an average positive likelihood ratio of 2.3 versus 2.6, and an average negative likelihood ratio 0.3 versus 0.4, respectively. Compared to invasive coronary angiography, the average effective radiation dose of CT coronary angiography was higher with retrospective electrocardiogram (ECG gating and relatively similar with prospective ECG gating. The health economic model using invasive coronary angiography as the reference standard showed that at a pretest probability of CHD of 50 % or lower, CT coronary angiography resulted in lower cost per patient with true positive diagnosis. At a pretest probability of CHD of 70 % or higher, invasive coronary angiography was associated with lower cost per patient with true positive diagnosis. Using intracoronary pressure measurement as the reference standard, both types of coronary angiographies resulted in substantially higher cost per patient with true positive diagnosis. Two publications dealing explicitly with ethical aspects were

  19. Coronary MR angiography: current status

    International Nuclear Information System (INIS)

    Danias, P.G.; Manning, W.J.

    2000-01-01

    Since first described in the early 1990s, coronary magnetic resonance angiography (MRA) has evolved as a promising noninvasive modality for imaging of the coronary arteries and evaluation of coronary artery disease. Despite technical limitations, coronary MRA has established value for imaging of anomalous coronary arteries and assessment of bypass graft patency. Current research focuses on the development of optimal respiratory compensation strategies, improved spatial and temporal resolution and faster acquisition of image data. The accurate detection of stenoses and assessment of the severity of coronary atherosclerosis is presently being evaluated with large multi-center studies. With further technique enhancements and more clinical experience, coronary MRA is likely to become the dominant noninvasive modality in clinical cardiology. (orig.) [de

  20. Decreased Diagnostic Accuracy of Multislice Coronary Computed Tomographic Angiography in Women with Atypical Angina Symptoms

    Directory of Open Access Journals (Sweden)

    Wen-Ying Jin

    2016-01-01

    Conclusions: Although MSCT is a reliable diagnostic modality for the exclusion of significant coronary artery stenoses in all patients, gender and atypical symptoms might have some influence on its diagnostic accuracy.

  1. [Comparison of 64 MDCT coronary CTA and coronary angiography in the detection of coronary artery stenosis in low risk patients with stable angina and acute coronary syndrome].

    Science.gov (United States)

    Cazalas, G; Sarran, A; Amabile, N; Chaumoitre, K; Marciano-Chagnaud, S; Jacquier, A; Paganelli, F; Panuel, M

    2009-09-01

    To determine the accuracy of 64 MDCT coronary CTA (CCTA) compared to coronary angiography in low risk patients with stable angina and acute coronary syndrome and determine the number of significant coronary artery stenoses ( 50%) in these patients. Materials and methods. Fifty-five patients underwent CCTA using a 32 MDCT unit with z flying focus allowing the acquisition of 64 slices of 0.6 mm thickness as well as coronary angiography (gold standard). Nine patients were excluded due to prior coronary artery bypass surgery (n=4), insufficient breath hold (n=3), calcium scoring>1000 (n=1) and delay between both examinations over 4 months (n=1). Forty-six patients: 27 males and 19 females were included. CCTA results were compared to coronary angiography per segment and artery with threshold detection of stenoses 50%. The degree of correlation between both examinations was performed using a regression analysis with a Pearson correlation coefficient<0.05 considered significant. The overall accuracy of CCTA was 90%; limitations related to the presence of calcifications, motion artifacts or insufficient vessel opacification. The correlation for all analyzed segments was 96.4%. Thirty-eight of 50 significant stenoses seen on coronary angiography were correctly detected on CCTA. Sensitivity, specificity, PPVC and NPV for detection of stenoses 50% were 76%, 98.3%, 80.3% and 97.7% respectively. Evaluation per segment had a NPV of 96.8% (interventricular and diagonal segments) to 100% (main trunk). Our results for specificity and NPV are similar to reports from the literature. This suggests that CCTA in this clinical setting may replace coronary angiography.

  2. Genetic engineering with endothelial nitric oxide synthase improves functional properties of endothelial progenitor cells from patients with coronary artery disease: an in vitro study.

    Science.gov (United States)

    Kaur, Savneet; Kumar, T R Santhosh; Uruno, Akira; Sugawara, Akira; Jayakumar, Karunakaran; Kartha, Chandrasekharan Cheranellore

    2009-11-01

    Recent studies have reported a marked impairment in the number and functions of endothelial progenitor cells (EPCs) in patients with coronary artery disease (CAD). In view of an important role of eNOS in angiogenesis, in the present study, we evaluated the effects of eNOS gene transfer in ex vivo expanded EPCs isolated from patients with CAD. The expanded EPCs were transfected with mammalian expression vector pcDNA3.1-eNOS containing the full-length human eNOS gene using lipofectamine. About 35-40% of the eNOS-EPCs had higher expression of eNOS as compared to untransfected EPCs. EPCs transfected with pcDNA3.0-EGFP, the plasmid vector expressing green fluorescent protein (GFP) were used as control. The untransfected, GFP-transfected and eNOS-transfected EPCs were compared in terms of important functional attributes of angiogenesis such as proliferation, migration, differentiation and adhesion/integration into tube-like structures in vitro. Functional studies revealed that in the presence of defined growth conditions, compared to the untransfected and GFP-transfected cells, eNOS-EPCs from patients with CAD have a significant increase in [3H] thymidine-labeled DNA (P < 0.01), migration (14.6 +/- 1.8 and 16.5 +/- 1.9 vs. 23.5 +/- 3.4 cells/field, P < 0.01), ability to differentiate into endothelial-like spindle-shaped cells (46 +/- 4.5 and 56.5 +/- 2.1 vs. 93.2 +/- 6.6 cells/field, P < 0.001) and also incorporation into tube-like structures on the matrigel (GFP-EPCs: 21.25 +/- 2.9 vs. GFP-eNOS-EPCs: 34.5 +/- 5.5 cells/field, P < 0.05). We conclude that eNOS gene transfection is a valuable approach to augment angiogenic properties of ex vivo expanded EPCs and eNOS-modified EPCs may offer significant advantages than EPCs alone in terms of their clinical use in patients with myocardial ischemia.

  3. Noninvasive Coronary Angiography using 64-Detector-Row Computed Tomography in Patients with a Low to Moderate Pretest Probability of Significant Coronary Artery Disease

    Energy Technology Data Exchange (ETDEWEB)

    Schlosser, T.; Mohrs, O.K.; Magedanz, A.; Nowak, B.; Voigtlaender, T.; Barkhausen, J.; Schmermund, A. [Dept. of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen (Germany)

    2007-04-15

    Purpose: To evaluate the value of 64-detector-row computed tomography for ruling out high-grade coronary stenoses in patients with a low to moderate pretest probability of significant coronary artery disease. Material and Methods: The study included 61 patients with a suspicion of coronary artery disease on the basis of atypical angina or ambiguous findings in noninvasive stress testing and a class II indication for invasive coronary angiography (ICA). All patients were examined by 64-detector-row computed tomography angiography (CTA) and ICA. On a coronary segmental level, the presence of significant (>50% diameter) stenoses was examined. Results: In a total of 915 segments, CTA detected 62 significant stenoses. Thirty-four significant stenoses were confirmed by ICA, whereas 28 stenoses could not be confirmed by ICA. Twenty-two of them showed wall irregularities on ICA, and six were angiographically normal. Accordingly, on a coronary segmental basis, 28 false-positive and 0 false-negative findings resulted in a sensitivity of 100%, a specificity of 96.8%, a positive predictive value of 54.8%, and a negative predictive value of 100%. The diagnostic accuracy was 96.9%. Conclusion: Sixty-four-detector-row computed tomography reliably detects significant coronary stenoses in patients with suspected coronary artery disease and appears to be helpful in the selection of patients who need to undergo ICA. Calcified and non-calcified plaques are detected. Grading of stenoses in areas with calcification is difficult. Frequently, stenosis severity is overestimated by 64-detector-row computed tomography.

  4. Noninvasive Coronary Angiography using 64-Detector-Row Computed Tomography in Patients with a Low to Moderate Pretest Probability of Significant Coronary Artery Disease

    International Nuclear Information System (INIS)

    Schlosser, T.; Mohrs, O.K.; Magedanz, A.; Nowak, B.; Voigtlaender, T.; Barkhausen, J.; Schmermund, A.

    2007-01-01

    Purpose: To evaluate the value of 64-detector-row computed tomography for ruling out high-grade coronary stenoses in patients with a low to moderate pretest probability of significant coronary artery disease. Material and Methods: The study included 61 patients with a suspicion of coronary artery disease on the basis of atypical angina or ambiguous findings in noninvasive stress testing and a class II indication for invasive coronary angiography (ICA). All patients were examined by 64-detector-row computed tomography angiography (CTA) and ICA. On a coronary segmental level, the presence of significant (>50% diameter) stenoses was examined. Results: In a total of 915 segments, CTA detected 62 significant stenoses. Thirty-four significant stenoses were confirmed by ICA, whereas 28 stenoses could not be confirmed by ICA. Twenty-two of them showed wall irregularities on ICA, and six were angiographically normal. Accordingly, on a coronary segmental basis, 28 false-positive and 0 false-negative findings resulted in a sensitivity of 100%, a specificity of 96.8%, a positive predictive value of 54.8%, and a negative predictive value of 100%. The diagnostic accuracy was 96.9%. Conclusion: Sixty-four-detector-row computed tomography reliably detects significant coronary stenoses in patients with suspected coronary artery disease and appears to be helpful in the selection of patients who need to undergo ICA. Calcified and non-calcified plaques are detected. Grading of stenoses in areas with calcification is difficult. Frequently, stenosis severity is overestimated by 64-detector-row computed tomography

  5. Complex Coronary Hemodynamics - Simple Analog Modelling as an Educational Tool.

    Science.gov (United States)

    Parikh, Gaurav R; Peter, Elvis; Kakouros, Nikolaos

    2017-01-01

    Invasive coronary angiography remains the cornerstone for evaluation of coronary stenoses despite there being a poor correlation between luminal loss assessment by coronary luminography and myocardial ischemia. This is especially true for coronary lesions deemed moderate by visual assessment. Coronary pressure-derived fractional flow reserve (FFR) has emerged as the gold standard for the evaluation of hemodynamic significance of coronary artery stenosis, which is cost effective and leads to improved patient outcomes. There are, however, several limitations to the use of FFR including the evaluation of serial stenoses. In this article, we discuss the electronic-hydraulic analogy and the utility of simple electrical modelling to mimic the coronary circulation and coronary stenoses. We exemplify the effect of tandem coronary lesions on the FFR by modelling of a patient with sequential disease segments and complex anatomy. We believe that such computational modelling can serve as a powerful educational tool to help clinicians better understand the complexity of coronary hemodynamics and improve patient care.

  6. Comparative angiographic quantitative analysis of the immediate efficacy of coronary atherectomy with balloon angioplasty, stenting, and rotational ablation

    NARCIS (Netherlands)

    V.A.W.M. Umans (Victor); B.H. Strauss (Bradley); B.J.W.M. Rensing (Benno); P.P.T. de Jaegere (Peter); P.J. de Feyter (Pim); P.W.J.C. Serruys (Patrick)

    1991-01-01

    textabstractInterventional cardiology has branched in two directions: devices that primarily dilate coronary stenoses and those that debulk coronary tissue. Presently the optimum coronary intervention has not been found. While patients are awaiting randomized trials, a comparison based on matched

  7. Scintigraphic anatomy of coronary artery disease in digital thallium-201 myocardial images

    International Nuclear Information System (INIS)

    Wainwright, R.J.

    1981-01-01

    One hundred and eight patients with single and multiple vessel coronary artery disease confirmed by arteriography were evaluated by exercise thallium-201 ( 201 Tl) myocardial scintigraphy to determine the scintigraphic appearances of specific coronary stenoses. In general proximal stenoses caused more widespread, but not necessarily more severe, myocardial tracer deficit, than distal stenoses. In particular, proximal dominant right coronary artery disease was specifically associated with extensive inferior wall tracer deficit in the anterior scintigram, whereas proximal left circumflex disease caused similar tracer depletion best visualised in the left lateral scintigram. A triad of uptake defects was caused by left anterior descending coronary artery disease; one of these defects called 'diagonal window tracer deficit' was the most useful scintigraphic sign distinguishing proximal from distal disease in the left anterior descending coronary artery. Certain scintigraphic patterns of 201 Tl myocardial accumulation appear invaluable in the noninvasive localisation of stenoses within specific coronary arteries and thus may be useful in predicting life-threatening coronary artery disease which should be confirmed by definitive coronary arteriography. The digital 201 Tl myocardial scintigram also provides an independent functional guide to the interpretation of coronary arteriograms and may be helpful in the planning of aortocoronary bypass graft surgery. (author)

  8. Frequency and importance of radiologically visible coronary scleroses

    International Nuclear Information System (INIS)

    Hoyer, B.

    1981-01-01

    The importance of radiologically visible coronary sceleroses for an early diagnosing of coronary heart disease was investigated. In 3 mixed collectives of patients with and without coronary heart diseases who had had a coronary angiography were examined retrospectively for coronary sclerosis (group I: standard films, group II: old X-ray findings, group III: fluoroscopy before beginning coronary angiography). In the retrospective evaluation, the sensitivity to the recognition of coronary heart disease was low. With prospective examination by means of fluoroscopy, coronary calcification could be proven in 37.66% of the patients with coronary diseases (sensitivity); the specificity (no coronary calcification in persons without coronary disease) was 99%. The duration and extent of a calcification do not show a definite influence on the severity of the disease. Several coronary scleroses in one or several vessels mostly indicate a vascular disease. Coronary scleroses are not necessarily located in the same point as coronary stenoses: in 85.5% of the patients with coronary sclerosis of the left truncus, haemodynamically important stenoses were found only in following vascular regions. Considering the high specificity of coronary scleroses in the fluoroscopic picture and the high sensitivity under favourable conditions, this method seems to be suitable as a screening method for early recognition of coronary heart diseases in the asymptomatic stage. A proven coronary sclerosis should in any case be the cause for continuing the search for a coronary heart disease. The radiation exposure during fluoroscopy of coronary sclerosis is low if the adjustment is correct, it takes little time, the patient is not put to discomfort. (orig./MG) [de

  9. Percutaneous transluminal angioplasty of stenoses of the proximal subclavian artery

    International Nuclear Information System (INIS)

    Grote, R.; Freyschmidt, J.; Walterbusch, G.; Medizinische Hochschule Hannover

    1983-01-01

    Between August 1980 and June 1982, 12 left-sided proximal subclavian stenoses were dilated with balloon catheters. The dilatation was successful in all patients. Differences in blood pressure in the arm could be demonstrated subsequently. Recurrences occurred in two patients after seven and eleven months. Follow-up of nine patients up to 24 months showed them to be symptom-free. (orig.)

  10. Fractional Flow Reserve Assessment of a Significant Coronary Stenosis Masked by a Downstream Serial Lesion

    Directory of Open Access Journals (Sweden)

    Lawrence Yu-Min Liu

    2016-01-01

    Full Text Available Fractional flow reserve (FFR has been recognized as an effective tool to determine functional significance in intermediate coronary lesions and FFR-guided percutaneous coronary intervention (PCI improves clinical outcomes. However, hemodynamic interaction between serial stenoses within one coronary artery complicates the assessment of functional severity of each individual lesion. We present a case in which FFR measurement by intracoronary bolus injection of adenosine helps to make appropriate revascularization decision in serial stenoses when the procedures are performed systemically and properly.

  11. Intravenous coronary angiography by electron beam computed tomography : a clinical evaluation

    NARCIS (Netherlands)

    Rensing, B J; Bongaerts, A; van Geuns, R J; van Ooijen, P; Oudkerk, M; de Feyter, P J

    1998-01-01

    BACKGROUND: -Noninvasive detection of coronary stenoses with electron beam CT (EBCT) after intravenous injection of contrast medium has recently emerged. We sought to determine the diagnostic accuracy of EBCT angiography in the clinical setting using conventional coronary angiography as the "gold

  12. Spiral CT angiography of middle cerebral artery stenoses

    International Nuclear Information System (INIS)

    Lehmann, K.J.; Neff, K.W.; Ries, S.; Sommer, A.; Steinke, W.; Georgi, M.

    1996-01-01

    Transcranial Doppler ultrasonography (TCD) and magnetic resonance angiography (MRA) are well-established techniques for ascertaining intracranial obstructive artery disease. The short examination time required for additional helical CT angiography (CTA) allows quick management of emergency patients already undergoing native CT. However, today the ability of CTA to detect stenoses of the middle cerebral artery (MCA) has not been proven. To analyse the value of CTA in the classification of atherosclerotic disease 23 MCA stenoses confirmed by TCD and MRA were investigated. CTA was performed on a Hispeed advantage scanner (GE) using a bolus injection of 70 ml KM and 40 ml NaCl with a flow rate of 2.5 ml/s, a thickness of 1 mm, a pitch of 1.5 and a 1 mm increment. CTA was presented as maximum intensity projection (MIP) and as multi-projection volume reconstruction (MPVR). A three-step classification of stenosis was compared with the results of TCD and MRA. Good opacification of the MCA was achieved in M1 and M2 segments in all patients. Classification of stenosis by CTA agreed with MRA and TCD in 14 cases; 7 stenoses were assigned to a lower classification by CTA. Two lowgrade stenoses could not be proven by CTA. Although MIP and MPVR yield the same result in stenosis classification MPVR showed a sharper image quality. In contrast to MRA, veins were highly opacified in CTA. Artery and vein were sometimes superimposed, which had to be avoided by changing the projection angle. Medium- and high-grade MCA stenoses can be demonstrated by CTA quickly and reliably. Compared to MRA and TCD, CTA provides lower grading of stenosis. (orig.) [de

  13. Angioplasty or Stenting of Extra- and Intracranial Vertebral Artery Stenoses

    International Nuclear Information System (INIS)

    Hauth, Elke A.M.; Gissler, H. Martin; Drescher, Robert; Jansen, Christian; Jaeger, Horst J.; Mathias, Klaus D.

    2004-01-01

    Purpose: To determine the feasibility and safety of angioplasty or angioplasty and stenting of extra- and intracranial vertebral artery (VA) stenosis. Methods: In 16 consecutive patients (9 men, 7 women; mean age 61 years, range 49-74 years) 16 stenotic VAs were treated with angioplasty orangioplasty and stenting. Eleven stenoses were localized in V1 segment,1 stenosis in V2 segment and 4 stenoses in V4 segment of VA. Fourteen VA stenoses were symptomatic, 2 asymptomatic. The etiology of the stenoses was atherosclerotic in all cases. Results:Angioplasty was performed in 8 of 11 V1 and 2 of 4 V4 segments of the VA. In 3 of 11 V1 segments and 2 of 4 V4 segments of the VA we combined angioplasty with stenting. The procedures were successfully performed in 14 of 16 VAs (87%). Complications were asymptomatic vessel dissection resulting in vessel occlusion in 1 of 11 V1 segments and asymptomatic vessel dissection in 2 of 4 V4 segments of the VA. One patient died in the 24-hr period after the procedure because of subarachnoid hemorrhage as a complication following vessel perforation of the treated V4 segment. Conclusion: Angioplasty orangioplasty and stenting of extracranial VA stenoses can be performed with a high technical success rate and a low complication rate. In intracranial VA stenosis the procedure is technically feasible but complications can be life-threatening. The durability and procedural complication rates of primary stenting without using predilation in extra- and intracranial VA stenosis should be defined in the future

  14. Influence of a small field-of-view size on the detection of coronary artery calcifications with MSCT: in vitro and in vivo study

    International Nuclear Information System (INIS)

    Mahnken, Andreas H.; Muehlenbruch, Georg; Das, Marco; Pohl, Saskia; Guenther, Rolf W.; Wildberger, Joachim E.; Koos, Ralf; Stanzel, Sven

    2006-01-01

    The purpose of this study is to asses the impact of small field-of-view (FOV) sizes on the detection of coronary artery calcifications using multislice-spiral computed tomography (MSCT). First, a static chest phantom containing calcium inserts was scanned 10 times using a standardized scan protocol. Secondly, 50 patients (28 male, 63.6±10.6 years) underwent cardiac MSCT using the same protocol. Images were reconstructed with three different FOV sizes (180 x 180, 220 x 220, 380 x 380 mm 2 ). Coronary calcium scoring and risk stratification were performed for each image series. In the phantom study, the Agatston score calculated with a FOV size of 180 x 180 mm 2 was 657.80±20.05. At a FOV of 220 x 220 mm 2 and 380 x 380 mm 2 , the corresponding values were 657.04±21.36 and 655.04±20.74, respectively. The corresponding values in the patient study were 541.65±869.87, 541.91±872.57 and 536.61±867.81. No statistically significant differences in the calcium score were found comparing different FOV sizes. Significantly more lesions (p=0.00149) were detected in the patient study. Comparing the different FOV sizes of 180 x 180 mm 2 and 220 x 220 mm 2 (380 x 380 mm 2 ), four (six) patients had to be assigned to different risk groups. The use of small FOV sizes resulted in an improved detection of coronary calcifications influencing the risk stratification for further cardiac events in MSCT coronary calcium scoring. (orig.)

  15. Atherosclerotic stenoses of renal arteries: Evaluation with CT

    International Nuclear Information System (INIS)

    Marteau, V.; Melki, J.P.; DuTemple, C.; Despres, E.; Taieb, A.

    1987-01-01

    Recent reports have shown that the long-term results of transluminal angioplasty (PTA) in renal arteries, performed to treat renovascular hypertension resulting from atherosclerotic disease, depended on the location, extent, and consistency of the obstructing lesions. Therefore, 30 patients shown with arteriography to have 40 atherosclerotic stenoses and five occlusions of the renal artery underwent CT for study of the walls of the aorta and renal arteries. CT easily demonstrates atherosclerotic lesions and seems better than arteriography when the lesions are ostial. It shows whether stenoses are calcified and also defines the lesions of the abdominal aorta, which is helpful when surgical bypass is considered. The paper presents the authors' preliminary findings. Long-term follow-up of these patients show if CT has a predictive value about PTA results

  16. Stenosing tenosynovitis of the flexors - or trigger finger

    Directory of Open Access Journals (Sweden)

    Rames Mattar Junior

    2008-03-01

    Full Text Available Stenosing tenosynovitis of the fl exors, known as trigger fi nger, is a verycommon problem seen by the Occupational Medicine practitioners,the orthopaedic surgeon and the hand surgeon. The purpose of thischapter is to summarize information on aspects of this conditionlikely to be of interest and relevant to the health professionals. Topicscovered include clinical observations related to ethiology, risk factors,diagnosis and case management.

  17. Gianturco-Rösch Z stents in tracheobronchial stenoses.

    Science.gov (United States)

    Petersen, B D; Uchida, B T; Barton, R E; Keller, F S; Rösch, J

    1995-01-01

    To evaluate expandable metallic Gianturco-Rösch Z (GRZ) stents for treatment of benign and malignant tracheobronchial stenoses. Six patients, ages 45-73 years, were treated for severe dyspnea with placement of GRZ stents. Three patients had benign tracheal lesions (one tracheomalacia, two postoperative) and received uncovered GRZ stents. Three patients had malignant stenoses at the level of the carina; one received an uncovered stent and the other two received silicone-covered GRZ stents. Two patients with benign lesions responded well to stent placement. One was asymptomatic for a year and then was lost to follow-up; the other improved substantially but died of end-stage lung disease 5 months after stent placement. A third patient with a benign high tracheal lesion did poorly; symptoms recurred secondary to inferior migration of a stent, which was removed surgically at 4 months. All patients with malignant lesions improved symptomatically after stent placement and remained without significant dyspnea until death (from 1 to 6 months). Expandable GRZ stents are promising devices for treatment of benign lesions and offer effective palliation of malignant tracheobronchial stenoses.

  18. The minimum coronary artery diameter in which coronary spasm can be identified by synchrotron radiation coronary angiography

    International Nuclear Information System (INIS)

    Matsushita, Shonosuke; Hyodo, Kazuyuki; Imazuru, Tomohiro; Tokunaga, Chiho; Sato, Fujio; Enomoto, Yoshiharu; Hiramatsu, Yuji; Sakakibara, Yuzuru

    2008-01-01

    Background: Coronary vasospasm is defined as a temporary, intense narrowing of the coronary conduit artery. It brings about ischemic chest pain and becomes one of the causes of myocardial infarction. Coronary spasms are divided into two categories. One is the coronary spasm of the conduit artery and the other is the coronary microvascular spasm. Although coronary spasms are diagnosed with the images of coronary angiography, microvascular spasms cannot be diagnosed because of the limitations of conventional angiographic systems. However, synchrotron radiation coronary angiography (SRCA) can identify coronary arteries down to 100 μm in diameter in the beating heart and 50 μm in arrested heart. Aim: The purpose of this study was to confirm whether microvascular spasms could be identified or not using SRCA, and then down that size identification was possible. Methods: The Langendorff perfusion system with isolated rat hearts was employed. Krebs-Henseleit solution (KH solution) was used as a perfusate. 10 mM of 4-aminopyridine (4-AP: a voltage-gated potassium channel blocker; spasm inducer) was added to the KH solution and maintained for 5 min. SRCA was performed at pre-, during and 10 min after cessation of the KH solution with 4-AP. Coronary spasms were defined as a temporal 75% reduction of coronary arterial diameter. Results and conclusion: Multiple sizes of coronary arteries showed coronary spasms. The minimum stenosed coronary artery size was 100 μm. Since coronary microvascular spasms are seen in the arterioles (50-400 μm), coronary microvascular spasms may be diagnosed with the use of synchrotron radiation coronary angiography

  19. Three-Dimensional Respiratory-Gated Coronary Mr Angiography with Reference to X-Ray Coronary Angiography

    International Nuclear Information System (INIS)

    Ikonen, A. E. J.; Manninen, H. I.; Vainio, P.; Vanninen, R. L.; Matsi, P. J.; Soimakallio, S.; Hirvonen, T.P.J.; Hartikainen, J.E.K.

    2003-01-01

    Purpose: To assess the clinical value of three-dimensional coronary MR angiography (CMRA) in the detection of significant coronary artery stenosis using conventional X-ray angiography as the standard reference. Material and Methods: Sixty-nine patients underwent X-ray coronary angiography and CMRA because of suspected or previously diagnosed coronary artery disease. MRI was performed with a 1.5-T whole body imaging system using ECG-triggered 3D gradient echo sequence with retrospective navigator echo respiratory gating and fat suppression. Results: A total of 276 coronary artery segments were analyzed. The X-ray coronary angiography was normal in 22 patients. Significant proximal stenoses (exceeding 50%) or occlusions were present in 102 coronary artery segments. In all, 120 stenoses or occlusions were identified in CMRA. Sixteen percent of the coronary artery segments had to be excluded because of poor image quality. The overall sensitivity and specificity for MRA for identification of significant stenosis were 75% and 62%, respectively. CMRA correctly detected 89% of patients with at least one vessel disease, but 6 patients with coronary artery disease would have been missed. Conclusions: Because of the high data exclusion and false-negative case rate, CMRA with retrospective navigator echo triggering is at present not suitable as a clinical screening method in coronary artery disease

  20. TU-H-CAMPUS-IeP2-03: Development of 3D Printed Coronary Phantoms for In-Vitro CT-FFR Validation Using Data from 320- Detector Row Coronary CT Angiography

    International Nuclear Information System (INIS)

    Ionita, C; Rudin, S; Bednarek, D; Zaid, S; Wilson, M; Angel, E; Mitsouras, D; Rybicki, F

    2016-01-01

    Purpose: To validate Computed Tomography Fractional Flow Reserve (CT-FFR) measurements with accurate 3D printed coronary phantoms. Methods: DICOM data from four phases in two patients imaged with a standard 320 × 0.5mm coronary CT acquisition (70–80% cardiac cycle) underwent semi-automated segmentation using a research workstation. Both patients had a >50% stenosis from the clinical image interpretation. Each volume was saved as a Stereo Lithographic (STL) file with 250 micron resolution. The 3D geometries were qualitatively assessed; the best of the four phases was 3D printed using a Stratasys Eden260V printer in Tango+, a rubber-like material that roughly emulates mechanical properties of human vasculature. We connected the model to a programmable pump and measured the pressure drop using pressure sensors embedded proximal and distal to the arterial stenosis. Next, the STL files used for the 3D printed models were uploaded in the ANSYS meshing tool (ICEM CFD 16.1). A standard meshing process was applied and the meshed geometry was directly imported in the ANSYS Fluent for Computational Flow Dynamics simulations. The CFD simulations were used to calculate the CT-FFR and compared to the bench top FFR measured in the 3D printed phantoms. Results: FFR-CT measurements and phantoms were completed in within an hour after the segmentation. Patient 1 had a 60% stenosis that resulted in a CT-FFR of 0.68. The second case had a 50% stenosis and a CT-FFR of 0.75. The average bench top FFR measurements were 0.72 and 0.80, respectively. Conclusion: This pilot investigation demonstrated the use of a bench-top coronary model for CT-FFR validation. The measurements and the CFD simulations agreed within 6%. Project supported by Support: Toshiba America Medical Systems Corp.and NIH grant R01-EB002873. Project supported by Toshiba America Medical Systems Corp.and partial support from NIH grant R01-EB002873

  1. TU-H-CAMPUS-IeP2-03: Development of 3D Printed Coronary Phantoms for In-Vitro CT-FFR Validation Using Data from 320- Detector Row Coronary CT Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Ionita, C; Rudin, S; Bednarek, D; Zaid, S; Wilson, M [University at Buffalo, Buffalo, NY (United States); Angel, E [Toshiba America Medical Systems, Inc, Tustin, CA (United States); Mitsouras, D [Brigham and Women’s Hospital, Boston, MA (United States); Rybicki, F [University of Ottawa, Ottawa, ON (Canada)

    2016-06-15

    Purpose: To validate Computed Tomography Fractional Flow Reserve (CT-FFR) measurements with accurate 3D printed coronary phantoms. Methods: DICOM data from four phases in two patients imaged with a standard 320 × 0.5mm coronary CT acquisition (70–80% cardiac cycle) underwent semi-automated segmentation using a research workstation. Both patients had a >50% stenosis from the clinical image interpretation. Each volume was saved as a Stereo Lithographic (STL) file with 250 micron resolution. The 3D geometries were qualitatively assessed; the best of the four phases was 3D printed using a Stratasys Eden260V printer in Tango+, a rubber-like material that roughly emulates mechanical properties of human vasculature. We connected the model to a programmable pump and measured the pressure drop using pressure sensors embedded proximal and distal to the arterial stenosis. Next, the STL files used for the 3D printed models were uploaded in the ANSYS meshing tool (ICEM CFD 16.1). A standard meshing process was applied and the meshed geometry was directly imported in the ANSYS Fluent for Computational Flow Dynamics simulations. The CFD simulations were used to calculate the CT-FFR and compared to the bench top FFR measured in the 3D printed phantoms. Results: FFR-CT measurements and phantoms were completed in within an hour after the segmentation. Patient 1 had a 60% stenosis that resulted in a CT-FFR of 0.68. The second case had a 50% stenosis and a CT-FFR of 0.75. The average bench top FFR measurements were 0.72 and 0.80, respectively. Conclusion: This pilot investigation demonstrated the use of a bench-top coronary model for CT-FFR validation. The measurements and the CFD simulations agreed within 6%. Project supported by Support: Toshiba America Medical Systems Corp.and NIH grant R01-EB002873. Project supported by Toshiba America Medical Systems Corp.and partial support from NIH grant R01-EB002873.

  2. Predicting the extent and location of coronary artery disease during the early postinfarction period by quantitative thallium-201 scintigraphy

    International Nuclear Information System (INIS)

    Gibson, R.S.; Taylor, G.J.; Watson, D.D.; Stebbins, P.T.; Martin, R.P.; Crampton, R.S.; Beller, G.A.

    1981-01-01

    The ability of quantitative thallium-201 scintigraphy to predict the extent and location of coronary artery disease before hospital discharge after acute myocardial infarction was evaluated in 52 patients. All patients underwent coronary angiography and serial thallium-201 imaging either at rest or after submaximal exercise stress. Two or three vessel disease was designated if abnormal thallium-201 uptake or washout patterns, or both, were seen in two or three vascular segments, respectively. Of 156 vessels analyzed in the 52 patients, 91 stenoses of 70 percent or greater were found by angiography. Seventy-four of these were predicted by scintigraphy. The specificity of scintigraphy for identifying vessel stenoses was 92 percent. Sensitivity for detecting and localizing stenoses supplying an infarct zone was 96 percent compared with 62 percent for stenoses supplying myocardium remote from the acute infarct. Perfusion abnormalities were more frequently seen in the distribution of vessels with severe stenoses than in those with moderate stenoses. Scintigraphy detected a greater proportion of left anterior descending and right coronary arterial stenoses than circumflex stenoses. In the 42 patients who underwent submaximal exercise testing, multivariate analysis of 23 clinical and laboratory variables identified multiple thallium-201 defects as the best predictor of multivessel disease. The predictive accuracy of exercise-induced S-T segment depression was only 45 percent compared with 88 percent for thallium-201 scintigraphy. Thallium-201 imaging at rest is reliable in assessing the extent of coronary disease in hospitalized patients who cannot undergo exercise testing because of unstable angina, uncompensated heart failure, poorly controlled arrhythmias or physical limitations

  3. Intraluminal ultrasound guidance of transverse laser coronary atherectomy

    Science.gov (United States)

    Aretz, H. Thomas; Martinelli, Michael A.; LeDet, Earl G.; Sedlacek, Tomas; Hatch, G. F.; Gregg, Richard E.

    1990-07-01

    A coronary laser atherectomy system combining laser delivery and ultrasonic imaging capability is described. The system is being developed by Intra-Sonix, Inc. to treat severe stenoses. The imaging system provides the clinician with the guidance needed to remove substantial plaque without perforation. The ultrasound transducers and laser optics are mounted in a small (less than 4 F), flexible catheter, that is deliverable over a standard guidewire (0.016 inch). The laser and ultrasound beams are directed at the artery wall to permit debulking of lesions and ultrasonic depth profiling of the tissue structure throughout the thickness of the artery. This allows the physician to determine the level of therapy to be applied and to monitor the plaque removal as the therapy progresses. The precise location of the ultrasound and laser beams in the artery is determined by a navigation system. Navigation data are processed electronically in conjunction with ultrasound data to produce real-time cross-sectional and longitudinal images of the artery wall at selected locations, which are updated as the catheter progresses through the vessel lumen. Results of in vitro tests on human atherosclerotic arteries and early in vivo experiments in a canine-human xenograft model showing image construction and radial laser delivery are discussed.

  4. Change in coronary blood flow after percutaneous coronary intervention in relation to baseline lesion physiology: results of the JUSTIFY-PCI study.

    Science.gov (United States)

    Nijjer, Sukhjinder S; Petraco, Ricardo; van de Hoef, Tim P; Sen, Sayan; van Lavieren, Martijn A; Foale, Rodney A; Meuwissen, Martijn; Broyd, Christopher; Echavarria-Pinto, Mauro; Al-Lamee, Rasha; Foin, Nicolas; Sethi, Amarjit; Malik, Iqbal S; Mikhail, Ghada W; Hughes, Alun D; Mayet, Jamil; Francis, Darrel P; Di Mario, Carlo; Escaned, Javier; Piek, Jan J; Davies, Justin E

    2015-06-01

    Percutaneous coronary intervention (PCI) aims to increase coronary blood flow by relieving epicardial obstruction. However, no study has objectively confirmed this and assessed changes in flow over different phases of the cardiac cycle. We quantified the change in resting and hyperemic flow velocity after PCI in stenoses defined physiologically by fractional flow reserve and other parameters. Seventy-five stenoses (67 patients) underwent paired flow velocity assessment before and after PCI. Flow velocity was measured over the whole cardiac cycle and the wave-free period. Mean fractional flow reserve was 0.68±0.02. Pre-PCI, hyperemic flow velocity is diminished in stenoses classed as physiologically significant compared with those classed nonsignificant (PPCI, resting flow velocity over the wave-free period increased little (5.6±1.6 cm/s) and significantly less than hyperemic flow velocity (21.2±3 cm/s; P0.80 had a significantly smaller gain (Δ4.6±2.3 cm/s; PPCI physiology is strongly associated with post-PCI increase in hyperemic coronary flow velocity. Hyperemic flow velocity increases 6-fold more when stenoses classed as physiologically significant undergo PCI than when nonsignificant stenoses are treated. Resting flow velocity measured over the wave-free period changes at least 4-fold less than hyperemic flow velocity after PCI. © 2015 American Heart Association, Inc.

  5. Change in Coronary Blood Flow After Percutaneous Coronary Intervention in Relation to Baseline Lesion Physiology Results of the JUSTIFY-PCI Study

    Science.gov (United States)

    Nijjer, Sukhjinder S.; Petraco, Ricardo; van de Hoef, Tim P.; Sen, Sayan; van Lavieren, Martijn A.; Foale, Rodney A.; Meuwissen, Martijn; Broyd, Christopher; Echavarria-Pinto, Mauro; Al-Lamee, Rasha; Foin, Nicolas; Sethi, Amarjit; Malik, Iqbal S.; Mikhail, Ghada W.; Hughes, Alun D.; Mayet, Jamil; Francis, Darrel P.; Di Mario, Carlo; Escaned, Javier; Piek, Jan J.; Davies, Justin E.

    2016-01-01

    Background Percutaneous coronary intervention (PCI) aims to increase coronary blood flow by relieving epicardial obstruction. However, no study has objectively confirmed this and assessed changes in flow over different phases of the cardiac cycle. We quantified the change in resting and hyperemic flow velocity after PCI in stenoses defined physiologically by fractional flow reserve and other parameters. Methods and Results Seventy-five stenoses (67 patients) underwent paired flow velocity assessment before and after PCI. Flow velocity was measured over the whole cardiac cycle and the wave-free period. Mean fractional flow reserve was 0.68±0.02. Pre-PCI, hyperemic flow velocity is diminished in stenoses classed as physiologically significant compared with those classed nonsignificant (PPCI, resting flow velocity over the wave-free period increased little (5.6±1.6 cm/s) and significantly less than hyperemic flow velocity (21.2±3 cm/s; P0.80 had a significantly smaller gain (Δ4.6±2.3 cm/s; PPCI physiology is strongly associated with post-PCI increase in hyperemic coronary flow velocity. Hyperemic flow velocity increases 6-fold more when stenoses classed as physiologically significant undergo PCI than when nonsignificant stenoses are treated. Resting flow velocity measured over the wave-free period changes at least 4-fold less than hyperemic flow velocity after PCI. PMID:26025217

  6. Influence of some drugs, used in coronary artery disease on in vitro labelling red blood cells with technetium 99mTc

    International Nuclear Information System (INIS)

    Poniatowicz-Frasunek, E.

    1997-01-01

    In some patients investigated by radionuclide ventriculography poor labeling efficiency of red blood cells with technetium 99m Tc is observed. Among possible mechanisms responsible for this phenomenon, the pharmacological treatment applied to the patients should be taken into consideration. The aim of the study was to define the effect of selected drugs used in CAD on technetium binding efficiency by erythrocytes in vitro. Blood samples were obtained from 40 normal individuals receiving no medication. The effect of the following drugs were examined: Aerosonit, Isoptin, Bemecor, Dopegyt, Enarenal, Binazin, Furosemid, Aspirin, Vitamin E and Propranolol. Only Enarenal and Vitamin E proved to have no effect on technetium binding efficiency. The most expressed reduction was observed in experiments with Aerosonit, Furosemid and Propranolol and the smallest changes were found in blood samples with Bemecor, Binazin and Aspirin. The results of the study suggest that pharmacological treatment may influence the quality of scintigraphic images obtained with radioisotope ventriculography. For that reason the medicines applied to the patients should be as much as possible reduced or withdrawn for at least several days before examination. (author)

  7. Imaging techniques in the diagnosis of coronary heart disease

    International Nuclear Information System (INIS)

    Frank, H.

    1997-01-01

    Coronary heart disease is the leading cause of death and disability worldwide. Coronary angiography makes it possible to visualize coronary artery stenosis and can be used for angioplasty and stent implantation; however, it does not allow the assessment of changes in myocardial microcirculation. The severity of an angiographically evaluated coronary stenosis does not always correspond to the extent of myocardial ischemia. Nonivasive techniques are needed to reexamine our reliance on coronary angiography and to explore the clinical value fo the physiological assessment of coronary artery stenoses. Such noninvasive techniques might become important tools in the future following an overal evaluation of coronary morphology, myocardial function and perfusion ascertained by all available methods. (orig.) [de

  8. THE PLURAL LESION CORONARY AND CYTOKINES DISBALANCE IN PATIENTS WITH CORONARY ATHEROSCLEROSIS

    Directory of Open Access Journals (Sweden)

    Martynov AV

    2012-12-01

    Full Text Available The aim of the study was to examine the levels of the main pro-inflammatory and anti-inflammatory cytokines in patients with ischemic heart disease, and the study of the possible impact of persistent herpes virus infection plural lesion coronary arteries. A total of 57 patients (mean age 49,3 ± 3,7 years IHD s hemodynamically significant stenoses of the coronary vessels. Conducted virological examination, including the definition of hypertension HSV1, HSV2, HHV6, SMV, VZV and VEB immunofluorescent and cytokines ІL-1β, ІL-6 ІL-8, TNF by ELISA in serum. Found increased levels of proinflammatory cytokines ІL-1β, ІL-6 and FNPα of IHD patients who had hemodynamically significant stenoses of coronary vessels. ІL-6 level in patients with 2 or more significant coronary artery lesions exceeded the rate of patients with a damaged coronary artery in 1.67 TNFα, ІL-8 - 1.37 ІL-1β and 1.28 times respectively. In patients with plural coronary vascular damage was the most common combination of CMV, VEB and HHV6. Since CMV was detected in more than 60% of patients with injuries of two spacecraft and nearly 76% from three spacecraft, VEB was detected in 72% and 88%, respectively.

  9. Segmental quantitative analysis of digital thallium-201 myocardial scintigrams in diagnosis of coronary artery disease

    International Nuclear Information System (INIS)

    Wainwright, R.J.; Maisey, M.N.; Sowton, E.

    1981-01-01

    One hundred and forty-nine patients with suspected ischaemic heart disease were evaluated by exercise thallium-201 myocardial scintigraphy ( 201 Tl SMS), single lead exercise electrocardiography, and coronary arteriography. Myocardial distribution of tracer was assessed semi-quantitatively from digital 201 Tl scintigrams and compared with tracer distribution in subjects with normal hearts. Fifty-two of 54 (96%) patients with normal coronary arteries had normal myocardial scintigrams whereas three patients had a positive ischaemic exercise electrocardiogram and were scan normal. Conversely, 36 of 95 (38%) patients with coronary artery disease had a positive ischaemic electrocardiogram compared with 94 of 95 (99%) patients who had a positive myocardial scintigram. Disease was predicted correctly in 76 out of 80 (95%) of left anterior descending coronary stenoses, in 48 out of 64 (75%) of right coronary artery stenoses, and in 55 out of 64 (85%) of left circumflex coronary artery stenoses, despite the presence of infarcted myocardium in other territories. 201 Tl SMS with segmental quantitative analysis is a highly sensitive and specific technique in the diagnosis of coronary artery disease and may be a useful screening procedure to select patients for further investigation, particularly those with evidence of life-threatening severe left coronary artery disease. (author)

  10. Prediction of blood pressure and blood flow in stenosed renal arteries using CFD

    Science.gov (United States)

    Jhunjhunwala, Pooja; Padole, P. M.; Thombre, S. B.; Sane, Atul

    2018-04-01

    In the present work an attempt is made to develop a diagnostive tool for renal artery stenosis (RAS) which is inexpensive and in-vitro. To analyse the effects of increase in the degree of severity of stenosis on hypertension and blood flow, haemodynamic parameters are studied by performing numerical simulations. A total of 16 stenosed models with varying degree of stenosis severity from 0-97.11% are assessed numerically. Blood is modelled as a shear-thinning, non-Newtonian fluid using the Carreau model. Computational Fluid Dynamics (CFD) analysis is carried out to compute the values of flow parameters like maximum velocity and maximum pressure attained by blood due to stenosis under pulsatile flow. These values are further used to compute the increase in blood pressure and decrease in available blood flow to kidney. The computed available blood flow and secondary hypertension for varying extent of stenosis are mapped by curve fitting technique using MATLAB and a mathematical model is developed. Based on these mathematical models, a quantification tool is developed for tentative prediction of probable availability of blood flow to the kidney and severity of stenosis if secondary hypertension is known.

  11. Detection of coronary calcium with electron beam tomography in coronary artery disease

    International Nuclear Information System (INIS)

    Haberl, R.; Knez, A.; Becker, A.; Becker, C.; Bruening, R.; Reiser, M.; Maass, A.; Steinbeck, G.

    1998-01-01

    Purpose: Coronary calcium is a powerful indicator of arteriosclerosis and can be detected very precisely with electron beam tomography. The method can be applied in patients with known coronary artery disease or in asymptomatic patients at risk of arteriosclerotic disease. Results: At the University of Munich we performed an EBT scan of the heart in 1100 patients within the last year. In 567 patients coronary angiography was performed also (±3 days). Confirming previous reports in the literature, we found a correlation of the calcium score with the age and gender of the patients. Severe coronary artery disease (stenoses ≥ 75%) was associated with significantly more calcium than less severe CAD. The calcium score did not discriminate between one-, two- and three-vessel disease. The site of calcification does not correlate with the localization of stenoses. Thirty-three percent of the patients with significant coronary artery disease showed a normal age-adjusted calcium score; a total of 8.1% of patients with severe stenoses did not reveal any coronary calcification (score =0). With asymptomatic patients there are only a few studies available. Soft plaques cannot be detected with EBT, but in most patients soft plaques occur together with hard plaques. Our results show that spiral CT of the newest generation may also be used for calcium screening. There was an excellent correlation of the calcium scores of EBT and spiral CT at all levels of calcification. Discussion: Coronary calcium is a sensitive marker of coronary artery disease. In the clinical setting EBT is indicated in patients with known coronary artery disease (to evaluate prognosis), in patients who are unable to perform a stress test, and in patients with atypical chest pain. However, lack of calcification may be associated with severe stenoses in a minority of patients. The clinical value in asymptomatic patients needs to be defined: Randomized studies are necessary. We see a possible indication in

  12. Expandable metallic stents for tracheobronchial stenoses in esophageal cancer.

    Science.gov (United States)

    Takamori, S; Fujita, H; Hayashi, A; Tayama, K; Mitsuoka, M; Ohtsuka, S; Shirouzu, K

    1996-09-01

    Tracheobronchial stenosis in patients with esophageal cancer can be life threatening. Few reports have discussed use of expandable metallic stents for central airway stenoses in patients with esophageal cancer. Twelve patients with esophageal cancer underwent placement of expandable metallic stents for respiratory distress caused by tracheobronchial stricture. Single or double metallic stents were placed in the stenotic airways under fluoroscopic guidance. Improvement in respiratory symptoms and clinical outcome were assessed. Most stenoses were located in the trachea or the left main bronchus. From one to four expandable metallic stents were placed in each stricture site, with immediate relief of respiratory symptoms in 8 patients. One patient with tracheomalacia in alive 3 years after stent placement and another is alive 6 months after stent insertion. The other 10 patients lived from 10 to 70 days (mean; survival, 35 days) after stent placement. Death was due to progression of disease. Although metallic stents are useful for relieving respiratory distress in patients with advanced esophageal cancer, additional therapies should be considered.

  13. Interobserver reliability of the Amsterdam Severity Scale in Stenosing Tenosynovitis (ASSiST)

    NARCIS (Netherlands)

    Peter, W.F.; Steultjens, M.P.M.; Mesman, T.; Dekker, J.; Hoeksma, A.F.

    2009-01-01

    STUDY DESIGN: Interobserver reliability study. INTRODUCTION: A scale was developed to measure the severity of stenosing tenosynovitis: the Amsterdam Severity Scale in Stenosing Tenosynovitis (ASSiST). PURPOSE OF THE STUDY: To study the interobserver reliability of the ASSiST. METHODS: Patients

  14. Late hemodynamic failure following percutaneous transluminal angioplasty for long and multifocal femoropopliteal stenoses

    DEFF Research Database (Denmark)

    Jørgensen, B; Tønnesen, K H; Holstein, P

    1991-01-01

    separate segments were dilated. Following 98% initial technical success, 3-year patency was 68% for single short stenoses, as opposed to 20% for long and multifocal stenoses (p = 0.05, logrank test). Antiplatelet therapy with acetylsalicyclic acid was not found to influence occurrence of restenosis...

  15. Comparison of exercise ECG and radionuclide ventriculography in the assessment of myocardial ischemia in patients with isolated stenoses of the left anterior descending artery

    International Nuclear Information System (INIS)

    Klepzig, H. Jr.; Mildenberger, D.; Kaltenbach, M.; Standke, R.; Baum, R.P.; Tezak, S.; Maul, F.D.; Hoer, G.

    1988-01-01

    21 patients with LAD-stenoses of at least 70% and 21 patients with LAD-stenoses and additional intramural anterior wall infarctions were studied. 20 patients without heart disease or after successful transluminal coronary angioplasty and 18 patients with intramural anterior wall infarction after successful transluminal dilatation of the LAD (remaining stenosis maximal 30%) served as controls. The normal range of global and regional left ventricular ejection fraction response to exercise was defined based on the data of 25 further patients without relevant coronary heart disease. Thus, a decrease in global ejection fraction and regional wall motion abnormalities were judged pathological. All patients were comparable with respect to age, ejection fraction at rest and work load. Myocardial ischemia could be detected by the exercise ECG in 81% of all patients without infarction and in 71% of patients with infarction. The corresponding values for global left ventricular ejection fraction were 76% and 81%, respectively, and for regional ejection fraction 95% in both groups. No false-positive exercise ECGs were observed in the healthy controls and 2(11%) in the corresponding group with intramural infaction. The global ejection fraction was pathological in 1(5%) healthy subject without infarction and in 3(17%) corresponding patients with infarction. Sectorial analysis revealed 5 and 22%, respectively. Our findings suggest that the exercise ECG has a limited sensitivity to detect myocardial ischemia in patients with isolated LAD-stenoses and intramural myocardial infarction. Radionuclide ventriculography yields pathological values more often; however, false-positive results also occur more frequently. (orig.) [de

  16. Multislice CT imaging of anomalous coronary arteries

    International Nuclear Information System (INIS)

    Shi Heshui; Aschoff, Andrik J.; Brambs, Hans-Juergen; Hoffmann, Martin H.K.

    2004-01-01

    The purpose of the present study was to evaluate the role of 16 multislice computed tomography (MSCT) to identify the origin of anomalous coronary arteries and to confirm their anatomic course in relation to the great vessels. Accuracy of coronary artery disease (CAD) detection was a secondary aim and was tested with conventional angiograms (CA) serving as standard of reference. Two hundred and forty-two consecutive patients referred for noninvasive coronary CT imaging were reviewed for the study. Sixteen patients (6.6%) with anomalous coronary arteries were detected and included as the study group. MSCT and CA images were analyzed in a blinded fashion for accuracy of anomalous artery origin and path detection. Results were compared in a secondary consensus evaluation. Accuracy ratios to detect CAD with MSCT in all vessels were calculated. Coronary anomalies for all 16 patients were correctly displayed on MSCT. CA alone achieved correct identification of the abnormality in only 53% (P=0.016). Sensitivity and specificity of MSCT to detect significantly stenosed vessels was 90 and 92%. 16-MSCT is accurate to delineate abnormally branching coronary arteries and allows sufficiently accurate detection of obstructive coronary artery disease in distal branches. It should therefore be considered as a prime non-invasive imaging tool for suspected coronary anomalies. (orig.)

  17. Regulation of Coronary Blood Flow in Health and Ischemic Heart Disease

    Science.gov (United States)

    Duncker, Dirk J.; Koller, Akos; Merkus, Daphne; Canty, John M.

    2018-01-01

    The major factors determining myocardial perfusion and oxygen delivery have been elucidated over the past several decades, and this knowledge has been incorporated into the management of patients with ischemic heart disease (IHD). The basic understanding of the fluid mechanical behavior of coronary stenoses has also been translated to the cardiac catheterization laboratory where measurements of coronary pressure distal to a stenosis and coronary flow are routinely obtained. However, the role of perturbations in coronary microvascular structure and function, due to myocardial hypertrophy or coronary microvascular dysfunction, in IHD is becoming increasingly recognized. Future studies should therefore be aimed at further improving our understanding of the integrated coronary microvascular mechanisms that control coronary blood flow, and of the underlying causes and mechanisms of coronary microvascular dysfunction. This knowledge will be essential to further improve the treatment of patients with IHD. PMID:25475073

  18. FDM Analysis for Blood Flow through Stenosed Tapered Arteries

    Directory of Open Access Journals (Sweden)

    Sankar DS

    2010-01-01

    Full Text Available Abstract A computational model is developed to analyze the unsteady flow of blood through stenosed tapered narrow arteries, treating blood as a two-fluid model with the suspension of all the erythrocytes in the core region as Herschel-Bulkley fluid and the plasma in the peripheral layer as Newtonian fluid. The finite difference method is employed to solve the resulting system of nonlinear partial differential equations. The effects of stenosis height, peripheral layer thickness, yield stress, viscosity ratio, angle of tapering and power law index on the velocity, wall shear stress, flow rate and the longitudinal impedance are analyzed. It is found that the velocity and flow rate increase with the increase of the peripheral layer thickness and decrease with the increase of the angle of tapering and depth of the stenosis. It is observed that the flow rate decreases nonlinearly with the increase of the viscosity ratio and yield stress. The estimates of the increase in the longitudinal impedance to flow are considerably lower for the two-fluid Herschel-Bulkley model compared with those of the single-fluid Herschel-Bulkley model. Hence, it is concluded that the presence of the peripheral layer helps in the functioning of the diseased arterial system.

  19. A tomographic approach to intravenous coronary arteriography

    International Nuclear Information System (INIS)

    Ritman, E.L.; Bove, A.A.

    1986-01-01

    Coronary artery anatomy can be visualized using high speed, volume scanning X-ray CT. A single scan during a bolus injection of contrast medium provides image data for display of all angles of view of the opacified coronary arterial tree. Due to the tomographic nature of volume image data the superposition of contrast filled cardiac chambers, such as would occur in the levophase of an intravenous injection of contrast agent, can be eliminated. Data are presented which support these statements. The Dynamic Spatial Reconstructor (DSR) was used to scan a life-like radiologic phantom of an adult human thorax in which the left atrial and ventricular chambers and the major epicardial coronary arteries were opacified so as to simulate the levophase of an intravenous injection of contrast agent. A catheter filled with diluted contrast agent and with regions of luminal narrowing (i.e. 'stenoses') was advanced along a tract equivalent to a right ventricular catheterization. Ease of visualization of the catheter 'stenoses' and the accuracy with which they can be measured are presented. (Auth.)

  20. Coronary 64-slice CT angiography predicts outcome in patients with known or suspected coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Gaemperli, Oliver; Valenta, Ines; Schepis, Tiziano [University Hospital Zurich NUK C 32, Cardiovascular Center, Zurich (Switzerland); Husmann, Lars; Scheffel, Hans; Desbiolles, Lotus; Leschka, Sebastian; Alkadhi, Hatem [University Hospital Zurich, Institute of Diagnostic Radiology, Zurich (Switzerland); Kaufmann, Philipp A. [University Hospital Zurich NUK C 32, Cardiovascular Center, Zurich (Switzerland); University of Zurich, Zurich Center for Integrative Human Physiology (ZIHP), Zurich (Switzerland)

    2008-06-15

    The aim of this study was to assess the prognostic value of 64-slice CT angiography (CTA) in patients with known or suspected coronary artery disease (CAD). Sixty-four-slice coronary CTA was performed in 220 patients [mean age 63 {+-} 11 years, 77 (35%) female] with known or suspected CAD. CTA images were analyzed with regard to the presence and number of coronary lesions. Patients were followed-up for the occurrence of the following clinical endpoints: death, nonfatal myocardial infarction, unstable angina, and coronary revascularization. During a mean follow-up of 14 {+-} 4 months, 59 patients (27%) reached at least one of the predefined clinical endpoints. Patients with abnormal coronary arteries on CTA (i.e., presence of coronary plaques) had a 1st-year event rate of 34%, whereas in patients with normal coronary arteries no events occurred (event rate, 0%, p < 0.001). Similarly, obstructive lesions ({>=}50% luminal narrowing) on CTA were associated with a high first-year event rate (59%) compared to patients without stenoses (3%, p < 0.001). The presence of obstructive lesions was a significant independent predictor of an adverse cardiac outcome. Sixty-four-slice CTA predicts cardiac events in patients with known or suspected CAD. Conversely, patients with normal coronary arteries on CTA have an excellent mid-term prognosis. (orig.)

  1. Evaluation of coronary artery disease by helical CT using retrospective ECG-gating

    International Nuclear Information System (INIS)

    Kawawa, Yoko

    2001-01-01

    The purpose of this study is to evaluate the usefulness of helical CT using retrospective ECG-gating for visualization of the coronary artery and detection of coronary artery disease. We performed a coronary artery phantom study and established this new application, with 1-mm collimation, 1-mm table increment, and 0.1-mm reconstruction (0.8 sec/rotation). Helical CT of 31 patients with 39 coronary artery diseases (34 coronary artery stenoses, 1 vasospastic angina, 1 coronary artery dissection, 1 coronary artery ectasia and 2 coronary artery aneurysms) was performed in a single breath hold and ECG-gating without and with intravenous injection of nonionic iodine contrast material. We selected the images which were not affected by cardiac motion from the reconstruction images, in order to visualize the coronary artery for detection of coronary artery disease. The coronary artery was well visualized in 32 out of 39 vessels (82%). A good visualization of the coronary artery was correlated with the heart rate. Further, in this well visualized group, coronary artery diseases were detected in 24 out of 31 cases (77%). One case of vasospastic angina was not included. It was difficult to detect coronary artery disease in cases of heavily calcified vessels or in the left circumflex artery. Helical CT using this retrospective ECG-gating is a useful noninvasive examination for evaluation of coronary artery disease. (author)

  2. Visualization of coronary arteries in patients after childhood Kawasaki syndrome: value of multidetector CT and MR imaging in comparison to conventional coronary catheterization

    International Nuclear Information System (INIS)

    Arnold, Raoul; Ley, Sebastian; Ley-Zaporozhan, Julia; Kauczor, Hans-Ulrich; Eichhorn, Joachim; Ulmer, Herbert; Schenk, Jens-Peter

    2007-01-01

    After childhood Kawasaki syndrome (KS) the coronary arteries undergo a lifelong dynamic pathological change, and follow-up coronary artery imaging is essential. At present, conventional coronary catheterization (CCC) and angiography is still regarded as the gold standard. Less-invasive methods such as multidetector CT angiography (MDCT-A) and MRI have been used sporadically. To compare the diagnostic quality of MDCT-A and MRI with that of CCC for coronary imaging in a group of patients with coronary artery pathology after childhood KS. A total of 16 patients (aged 5-27 years) underwent CCC and 16-row MDCT-A and 14 patients MRI (1.5 T). There was 100% agreement between MDCT-A and CCC in the detection of coronary aneurysms and stenoses. MDCT-A was superior for the visualization of calcified lesions. MRI and CCC showed 93% agreement for the detection of aneurysms. Visualization of coronary artery stenoses was difficult using MRI - one stenosis was missed. MDCT-A has excellent correlation with CCC regarding all changes affecting the coronary arteries in the follow-up of childhood KS. In comparison to MDCT-A and CCC, MRI is less precise in the detection of stenotic lesions. Due to its high image quality and ease of performance MDCT-A should be the primary diagnostic modality in patients following childhood KS. (orig.)

  3. Diastolic timed Vibro-Percussion at 50 Hz delivered across a chest wall sized meat barrier enhances clot dissolution and remotely administered Streptokinase effectiveness in an in-vitro model of acute coronary thrombosis

    OpenAIRE

    Hoffmann, Andrew; Gill, Harjit

    2012-01-01

    Abstract Background Low Frequency Vibro-Percussion (LFVP) assists clearance of thrombi in catheter systems and when applied to the heart and timed to diastole is known to enhance coronary flow. However LFVP on a clotted coronary like vessel given engagement over a chest wall sized barrier (to resemble non-invasive heart attack therapy) requires study. Methods One hour old clots (n=16) were dispensed within a flexible segment of Soft-Flo catheter (4 mm lumen), weighted, interfaced with Heparin...

  4. Sudden Death Due to Coronary Artery Lesions Long-term After the Arterial Switch Operation: A Systematic Review.

    NARCIS (Netherlands)

    van Wijk, Sebastiaan W.H.; van der Stelt, Femke; ter Heide, Henriëtte; Schoof, Paul H.; Doevendans, Pieter A.F.M.; Meijboom, Folkert J.; Breur, Johannes M.P.J.

    2017-01-01

    Background The arterial switch operation (ASO) is the preferred procedure for children with dextrotransposition of the great arteries or Taussig-Bing anomaly. Short- as well as long-term outcome of ASO are excellent, but coronary artery stenoses are reported as a common long-term complication. It

  5. Treatment of intracranial stenoses using the Neuroform stent system: initial experience in five cases

    International Nuclear Information System (INIS)

    Haehnel, Stefan; Hartmann, Marius; Ringleb, Peter

    2006-01-01

    We assessed the technical feasibility of balloon-assisted angioplasty with consecutive stenting using a flexible, self-expanding neurovascular stent for the treatment of intracranial arteriosclerotic vascular stenoses. Five consecutive patients with symptomatic drug-resistant stenoses of the intracranial internal carotid artery (ICA) or the main stem of the middle cerebral artery (MCA) were treated by balloon-assisted angioplasty with consecutive stenting using the Neuroform stent system. Balloon dilatation of the stenoses and consecutive stent placement with complete coverage of the stenoses was feasible in all patients. One patient suffered acute thrombosis distally to the stented vessel segment which was successfully treated by fibrinolysis, and one patient suffered acute subarachnoid and parenchymal hemorrhage probably due to vessel perforation. In the other three patients, no complications occurred during or immediately after angioplasty. All patients were free of further ischemic events up to the 6-month follow-up. Our findings demonstrate that the Neuroform stent system can used successfully for the treatment of intracranial stenoses of the ICA and the main stem of the MCA. Although immediate angiographic results are promising, long-term angiographic and clinical follow-up is essential to demonstrate long-term outcome. (orig.)

  6. Accuracy of 3 T MR angiography in vertebral artery stenosis and coincidence with other cerebrovascular stenoses

    International Nuclear Information System (INIS)

    Choi, Hyun Seok; Kim, Dong Ik; Kim, Dong Joon; Kim, Jinna; Kim, Eun Soo; Lee, Seung-Koo

    2010-01-01

    Ostium of vertebral artery (VA) is a common site of pseudostenosis on contrast-enhanced MR angiography (CE-MRA). The purpose of this study was to determine the diagnostic accuracy of CE-MRA at 3 T in the evaluation of ostial stenosis of VA and to find associated coincidental stenoses using logistic regression analysis. One hundred and thirty-five VA ostial regions from 72 patients who received CE-MRA of neck vessels, intracranial time of flight (TOF) MRA, and digital subtraction angiography (DSA) were retrospectively reviewed. The sensitivity and specificity of the CE-MRA in detection of ostial stenosis were calculated with reference standard of DSA. Ostial stenosis on MRA was correlated with coincidental lesions in intracranial and cervical arteries by logistic regression analysis. The sensitivity and specificity of the CE-MRA were 100% and 80.4% for detection of significant stenosis. In case of significant stenoses, CE-MRA showed a tendency of overestimation with a false-positive rate of 52.5%. Logistic regression analysis showed that the stenoses of middle cerebral artery (MCA) on TOF MRA was associated with significant stenoses of VA ostia (OR = 5.84, 95% confidence intervals 1.41-24.17). CE-MRA is sensitive in detection of VA ostial stenosis although it has high false-positive rate. True positive ostial stenosis should be considered in cases of coincidental stenoses of MCA on TOF MRA. (orig.)

  7. Experimental models of tracheobronchial stenoses: a useful tool for evaluating airway stents.

    Science.gov (United States)

    Marquette, C H; Mensier, E; Copin, M C; Desmidt, A; Freitag, L; Witt, C; Petyt, L; Ramon, P

    1995-09-01

    Stent implantation is a conservative alternative to open operation for treating benign tracheobronchial strictures. Most of the presently available stents were primarily designed for endovascular use. Their respiratory use entails a risk of iatrogenic complications. From a scientific and from an ethical point of view these risks justify preclinical evaluation of new respiratory stents in experimental models of central airway stenoses. Therefore, an attempt was made to develop such models in piglets and adult minipigs. Tracheal stenoses were obtained by creating first a segmental tracheomalacia through extramucosal resection of cartilaginous arches. The fibrous component of the stenoses was then obtained through bronchoscopic application of a caustic agent causing progressive deep mucosal and submucosal injury. Stenoses of the main bronchi were created by topical application of the caustic agent only. These models demonstrated the typical features of benign fibromalacic tracheobronchial stenoses with constant recurrence after mechanical dilation. Preliminary experiments showed that short-term problems of tolerance of stent prototypes are easily demonstrable in these models. These experimental models, which simulate quite realistically human diseases, offer the opportunity to perfect new tracheobronchial stents specifically designed for respiratory use and to evaluate their long-term tolerance before their use in humans.

  8. Does grafting coronary arteries with only moderate stenosis affect long-term mortality?

    Science.gov (United States)

    Sabik, Joseph F.; Olivares, Gabriel; Raza, Sajjad; Lytle, Bruce W.; Houghtaling, Penny L.; Blackstone, Eugene H.

    2016-01-01

    Objective Stenting coronary arteries with non–ischemia-producing moderate stenosis leads to worse outcomes than leaving them unstented. We sought to determine whether grafting coronary arteries with angiographically moderate stenosis is associated with worse long-term survival than leaving them ungrafted. Methods From 1972 to 2011, 55,567 patients underwent primary isolated coronary artery bypass grafting (CABG); 8531 had a single coronary artery with moderate (50%-69%) stenosis, bypassed in 6598 (77%) and not bypassed in 1933 (23%). These arteries were grafted with internal thoracic arteries (ITAs) in 1806 patients (27%) and with saphenous veins (SVs) in 4625 (70%). Mean follow-up for all-cause mortality was 13.0 ± 9.7 years. Results Survival was similar for patients with and without a graft to the moderately stenosed coronary artery (P = .3): 97%, 76%, 43%, and 18% at 1, 10, 20, and 30 years among patients receiving no graft; 97%, 74%, 41%, and 18% among those receiving an SV graft; and 98%, 82%, 51%, and 23% among those receiving an ITA graft. After adjusting for patient characteristics, SV grafting versus nongrafting of moderately stenosed coronary arteries was associated with similar long-term mortality (P = .2), whereas ITA grafting was associated with 22% lower long-term mortality (hazard ratio 0.78; 68% confidence interval 0.75–0.82; P<.0001). Conclusions Grafting coronary arteries with angiographically moderate stenosis is not harmful. Instead, ITA grafting of such coronary arteries is associated with lower long-term mortality. Thus, after placing the first ITA to the left anterior descending, the second ITA should be placed to the second most important coronary artery, even if it is moderately stenosed. PMID:26611750

  9. In vitro model of platelet aggregation in stenotic arteries

    International Nuclear Information System (INIS)

    Morley, D.; Santamore, W.P.

    1988-01-01

    Clinical and experimental evidence suggest a strong relationship between arterial stenosis, platelet aggregation, and subsequent thrombus formation. To facilitate the study of platelet accumulation in stenotic arteries, we developed an in vitro preparation. Arterial segments were perfused with whole citrated blood. A stenosis was created by applying an external plastic constrictor to the artery. Platelet accumulation within the stenosis was assessed by scanning electron microscopy and by radioactive counts from Indium-111 labeled platelets. Utilizing this preparation, 30 carotid arterial segments from 10 mongrel dogs were perfused at 100 mmHg for 15 min. In 10 arteries without a stenosis, scanning electron microscopy and radioactive counts demonstrated little platelet accumulation. In contrast, extensive platelet aggregation was observed in 10 arteries with stenoses. Moreover, in 10 stenotic arteries exposed to the thromboxane mimetic, U46619 (Upjohn Diagnostic Group), scanning electron microscopy and radioactive counts demonstrated a significant increase in platelet deposition. Conversely, we demonstrated a dimunition of platelet accumulation in stenosed arterial segments exposed to the prostacyclin analogue platelet inhibitor, Iloprost. The in vitro preparation allows precise control of hemodynamic variables and makes it possible to perform multiple tests on segments of the same vessel from the same animal

  10. Analysis of the flow in stenosed carotid artery bifurcation models--hydrogen-bubble visualisation.

    Science.gov (United States)

    Palmen, D E; van de Vosse, F N; Janssen, J D; van Dongen, M E

    1994-05-01

    This paper deals with the effect of geometric changes of mild stenoses on large-scale flow disturbances in the carotid artery bifurcation. Hydrogen-bubble visualisation experiments have been performed in Plexiglas models of a non-stenosed and a 25% stenosed carotid artery bifurcation. The flow conditions approximate physiological flow. The experiments show that shortly after the onset of the diastolic phase vortex formation occurs in the plane of symmetry. This vortex formation is found in a shear layer, which is formed in the carotid sinus. The shear layer is located between a region with low shear rates at the non-divider wall and a region with high shear rates at the divider wall. In order to gain insight into the parameters that are important with respect to the stability of the shear layer, experiments have been performed in which the influence of the shape of the flow pulse, the Reynolds number (Re), the Womersley parameter (alpha) and the flow division ratio (gamma) on the flow phenomena is studied. From these experiments it appears that the flow phenomena in the carotid artery bifurcation are significantly influenced by Re, alpha the systolic acceleration (sa) and deceleration (sd) and the duration of the peak-systolic flow (Tmax). With these results a simplified flow pulse is chosen, with which the experiments in the non-stenosed and the 25% stenosed bifurcation are performed. Comparison of the hydrogen-bubble profiles in the 0 and 25% stenosed models with similar flow conditions shows that the geometric change of the 25% stenosis only slightly influences the flow phenomena. The most striking influences are found in the stability of the shear layer. Quantitative experiments by means of laser Doppler anemometry measurements and numerical computations are needed to analyse the influence of the stenosis of the flow field more accurately.

  11. Predictors of Stenosing Tenosynovitis in the Hand and Hand-Related Activity Limitations in Patients With Rheumatoid Arthritis

    NARCIS (Netherlands)

    Ursum, J.; Horsten, N.C.; Hoeksma, A.F.; Dijkmans, B.A.C.; Knol, D.L.; van Schaardenburg, D.; Dekker, J.; Roorda, L.D.

    2011-01-01

    Ursum J, Horsten NC, Hoeksma AF, Dijkmans BA, Knol DL, van Schaardenburg D, Dekker J, Roorda LD. Predictors of stenosing tenosynovitis in the hand and hand-related activity limitations in patients with rheumatoid arthritis. Objectives To identify early predictors of stenosing tenosynovitis in the

  12. Estimation of the flow resistances exerted in coronary arteries using a vessel length-based method.

    Science.gov (United States)

    Lee, Kyung Eun; Kwon, Soon-Sung; Ji, Yoon Cheol; Shin, Eun-Seok; Choi, Jin-Ho; Kim, Sung Joon; Shim, Eun Bo

    2016-08-01

    Flow resistances exerted in the coronary arteries are the key parameters for the image-based computer simulation of coronary hemodynamics. The resistances depend on the anatomical characteristics of the coronary system. A simple and reliable estimation of the resistances is a compulsory procedure to compute the fractional flow reserve (FFR) of stenosed coronary arteries, an important clinical index of coronary artery disease. The cardiac muscle volume reconstructed from computed tomography (CT) images has been used to assess the resistance of the feeding coronary artery (muscle volume-based method). In this study, we estimate the flow resistances exerted in coronary arteries by using a novel method. Based on a physiological observation that longer coronary arteries have more daughter branches feeding a larger mass of cardiac muscle, the method measures the vessel lengths from coronary angiogram or CT images (vessel length-based method) and predicts the coronary flow resistances. The underlying equations are derived from the physiological relation among flow rate, resistance, and vessel length. To validate the present estimation method, we calculate the coronary flow division over coronary major arteries for 50 patients using the vessel length-based method as well as the muscle volume-based one. These results are compared with the direct measurements in a clinical study. Further proving the usefulness of the present method, we compute the coronary FFR from the images of optical coherence tomography.

  13. Prospective Coronary Heart Disease Screening in Asymptomatic Hodgkin Lymphoma Patients Using Coronary Computed Tomography Angiography: Results and Risk Factor Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Girinsky, Theodore, E-mail: girinsky.theodore@orange.fr [Department of Radiation Oncology, Institut Gustave Roussy, Villejuif (France); M’Kacher, Radhia [Laboratory of Radiobiology and Oncology, Institut de Radiobiologie Cellulaire et Moleculaire/Direction des Sciences Vivantes/Commissariat Energie Atomique, Fontenay aux Roses (France); Lessard, Nathalie [Department of Radiation Oncology, Institut Gustave Roussy, Villejuif (France); Koscielny, Serge [Biostatistics and Epidemiology Unit, Institut Gustave Roussy, Villejuif (France); Elfassy, Eric; Raoux, François [Department of Radiology, Marie Lannelongue, Chatenay-Malabry (France); Carde, Patrice [Department of Hematology, Institut Gustave Roussy, Villejuif (France); Santos, Marcos Dos [Department of Radiation Oncology, Institut Gustave Roussy, Villejuif (France); Margainaud, Jean-Pierre [Department of Head and Neck Surgery, Institut Gustave Roussy, Villejuif (France); Sabatier, Laure [Laboratory of Radiobiology and Oncology, Institut de Radiobiologie Cellulaire et Moleculaire/Direction des Sciences Vivantes/Commissariat Energie Atomique, Fontenay aux Roses (France); Ghalibafian, Mithra [Department of Radiation Oncology, Institut Gustave Roussy, Villejuif (France); Paul, Jean-François [Department of Radiology, Marie Lannelongue, Chatenay-Malabry (France)

    2014-05-01

    Purpose: To prospectively investigate the coronary artery status using coronary CT angiography (CCTA) in patients with Hodgkin lymphoma treated with combined modalities and mediastinal irradiation. Methods and Materials: All consecutive asymptomatic patients with Hodgkin lymphoma entered the study during follow-up, from August 2007 to May 2012. Coronary CT angiography was performed, and risk factors were recorded along with leukocyte telomere length (LTL) measurements. Results: One hundred seventy-nine patients entered the 5-year study. The median follow-up was 11.6 years (range, 2.1-40.2 years), and the median interval between treatment and the CCTA was 9.5 years (range, 0.5-40 years). Coronary artery abnormalities were demonstrated in 46 patients (26%). Coronary CT angiography abnormalities were detected in nearly 15% of the patients within the first 5 years after treatment. A significant increase (34%) occurred 10 years after treatment (P=.05). Stenoses were mostly nonostial. Severe stenoses were observed in 12 (6.7%) of the patients, entailing surgery with either angioplasty with stent placement or bypass grafting in 10 of them (5.5%). A multivariate analysis demonstrated that age at treatment, hypertension, and hypercholesterolemia, as well as radiation dose to the coronary artery origins, were prognostic factors. In the group of patients with LTL measurements, hypertension and LTL were the only independent risk factors. Conclusions: The findings suggest that CCTA can identify asymptomatic individuals at risk of acute coronary artery disease who might require either preventive or curative measures. Conventional risk factors and the radiation dose to coronary artery origins were independent prognostic factors. The prognostic value of LTL needs further investigation.

  14. In vitro measurement of CT density and estimation of stenosis related to coronary soft plaque at 100 kV and 120 kV on ECG-triggered scan

    Energy Technology Data Exchange (ETDEWEB)

    Horiguchi, Jun, E-mail: horiguch@hiroshima-u.ac.jp [Department of Clinical Radiology, Hiroshima University Hospital, 1-2-3, Kasumi-cho, Minami-ku, Hiroshima 734-8551 (Japan); Fujioka, Chikako, E-mail: fujioka@hiroshima-u.ac.jp [Department of Clinical Radiology, Hiroshima University Hospital, 1-2-3, Kasumi-cho, Minami-ku, Hiroshima 734-8551 (Japan); Kiguchi, Masao, E-mail: kiguchi@hiroshima-u.ac.jp [Department of Clinical Radiology, Hiroshima University Hospital, 1-2-3, Kasumi-cho, Minami-ku, Hiroshima 734-8551 (Japan); Yamamoto, Hideya, E-mail: hideyayama@hiroshima-u.ac.jp [Department of Cardiovascular Medicine, Hiroshima University Graduate School of Biomedical Sciences and Hiroshima University Hospital, 1-2-3, Kasumi-cho, Minami-ku, Hiroshima 734-8551 (Japan); Shen, Yun, E-mail: Yuna.Shen@ge.com [CT Lab of Great China, GE Healthcare, L12 and L15, Office Tower, Langham Place, 8 Argyle Street, Mongkok Kowloon (Hong Kong); Kihara, Yasuki, E-mail: ykihara@hiroshima-u.ac.jp [Department of Cardiovascular Medicine, Hiroshima University Graduate School of Biomedical Sciences and Hiroshima University Hospital, 1-2-3, Kasumi-cho, Minami-ku, Hiroshima 734-8551 (Japan)

    2011-02-15

    Purpose: The purpose of the study was to compare 100 kV and 120 kV prospective electrocardiograph (ECG)-triggered axial coronary 64-detector CT angiography (64-MDCTA) in soft plaque diagnosis. Materials and methods: Coronary artery models (n = 5) with artificial soft plaques (-32 HU to 53 HU at 120 kV) with three stenosis levels (25%, 50% and 75%) on a cardiac phantom (mimicking slim patient's environment) were scanned in heart rates of 55, 60 and 65 beats per minute (bpm). Four kinds of intracoronary enhancement (205 HU, 241 HU, 280 HU and 314 HU) were simulated. The soft plaque density and the measurement error of stenosis (in percentage), evaluated by two independent observers, were compared between 100 kV and 120 kV. The radiation dose was estimated. Results: Interobserver correlation of the measurement was excellent (density; r = 0.95 and stenosis measure; r = 0.97). Neither the density of soft plaque nor the measurement error of stenosis was different between 100 kV and 120 kV (p = 0.22 and 0.08). The estimated radiation doses were 2.0 mSv and 3.3 mSv (in 14 cm coverage) on 100 kV and 120 kV prospective ECG-triggered axial scans, respectively. Conclusion: The 100 kV prospective ECG-triggered coronary MDCTA has comparable performance to 120 kV coronary CTA in terms of soft plaque densitometry and measurement of stenosis, with a reduced effective dose of 2 mSv.

  15. Should incidental asymptomatic angiographic stenoses and occlusions be treated in patients with peripheral arterial disease?

    LENUS (Irish Health Repository)

    Keeling, Aoife N

    2009-09-01

    The clinical importance of angiographically detected asymptomatic lower-limb stenoses and occlusions is unknown. This study aims to (i) assess the clinical outcome of asymptomatic lesions in the lower limb, (ii) identify predictors of clinical deterioration, and (iii) determine which asymptomatic lower-limb lesions should be treated at presentation.

  16. Computational Fluid Dynamics Analysis of Pulsatile Blood Flow Behavior in Modelled Stenosed Vessels with Different Severities

    Directory of Open Access Journals (Sweden)

    Mohsen Mehrabi

    2012-01-01

    Full Text Available This study focuses on the behavior of blood flow in the stenosed vessels. Blood is modelled as an incompressible non-Newtonian fluid which is based on the power law viscosity model. A numerical technique based on the finite difference method is developed to simulate the blood flow taking into account the transient periodic behaviour of the blood flow in cardiac cycles. Also, pulsatile blood flow in the stenosed vessel is based on the Womersley model, and fluid flow in the lumen region is governed by the continuity equation and the Navier-Stokes equations. In this study, the stenosis shape is cosine by using Tu and Devil model. Comparing the results obtained from three stenosed vessels with 30%, 50%, and 75% area severity, we find that higher percent-area severity of stenosis leads to higher extrapressure jumps and higher blood speeds around the stenosis site. Also, we observe that the size of the stenosis in stenosed vessels does influence the blood flow. A little change on the cross-sectional value makes vast change on the blood flow rate. This simulation helps the people working in the field of physiological fluid dynamics as well as the medical practitioners.

  17. Diastolic timed Vibro-Percussion at 50 Hz delivered across a chest wall sized meat barrier enhances clot dissolution and remotely administered Streptokinase effectiveness in an in-vitro model of acute coronary thrombosis

    Directory of Open Access Journals (Sweden)

    Hoffmann Andrew

    2012-11-01

    Full Text Available Abstract Background Low Frequency Vibro-Percussion (LFVP assists clearance of thrombi in catheter systems and when applied to the heart and timed to diastole is known to enhance coronary flow. However LFVP on a clotted coronary like vessel given engagement over a chest wall sized barrier (to resemble non-invasive heart attack therapy requires study. Methods One hour old clots (n=16 were dispensed within a flexible segment of Soft-Flo catheter (4 mm lumen, weighted, interfaced with Heparinized Saline (HS, secured atop a curved dampening base, and photographed. A ~4 cm meat slab was placed over the segment and randomized to receive intermittent LFVP (engaged, - disengaged at 1 second intervals, or no LFVP for 20 minutes. HS was pulsed (~120/80 mmHg, with the diastolic phase coordinated to match LFVP delivery. The segment was then re-photographed and aspirated of fluid to determine post clot weight. The trial was then repeated with 0.5 mls of Streptokinase (15,000 IU/100 microlitre delivered ~ 2 cm upstream from the clot. Results LFVP - HS only samples (vs. controls showed; a development of clot length fluid channels absent in the control group (p Conclusion Diastolic timed LFVP (50 Hz engaged across a chest wall sized barrier enhances clot disruptive effects to an underlying coronary like system.

  18. Quantitative exercise technetium-99m tetrofosmin myocardial tomography for the identification and localization of coronary artery disease

    International Nuclear Information System (INIS)

    Sullo, P.; Cuocolo, A.; Nicolai, E.; Cardei, S.; Nappi, A.; Squame, F.; Covelli, E.M.; Pace, L.; Salvatore, M.

    1996-01-01

    The aim of this study was to evaluate the accuracy of quantitative 1-day exercise-rest technetium-99m tetrofosmin tomography in the identification of patients with coronary artery disease (CAD) and in the detection of individual stenosed coronary vessels. Sixty-one patients with suspected CAD who underwent coronary angiography and 13 normal volunteers were studied. All patients were submitted to two i.v. injections of 99m Tc-tetrofosmin, one at peak exercise (370 MBq) and the other (1110 MBq) at rest 3 h after exercise (images 15-30 min after injection for both studies). All patients with CAD (≥50% luminal stenosis) (n=50) had an abnormal 99m Tc-tetrofosmin tomogram. Only one patient without significant coronary narrowing showed abnormal findings. Overall senstivity, specificity and diagnostic accuracy in the detection of individual stenosed vissels were 77%, 93% and 85%, respectively. Sensitivity and diagnostic accuracy in the identification of individuals stenosed coronary vessels were significantly higher (P 75%). (orig.)

  19. Multislice computed tomographic coronary angiography: experience in a UK centre

    International Nuclear Information System (INIS)

    Morgan-Hughes, G.J.; Marshall, A.J.; Roobottom, C.A.

    2003-01-01

    AIM: To evaluate the technique of coronary angiography with retrospectively electrocardiogram (ECG)-gated four-slice helical computed tomography (CT). MATERIALS AND METHODS: Within 1 month of undergoing routine day-case diagnostic coronary angiography, 30 consecutive patients also underwent retrospectively ECG-gated multislice CT coronary angiography. This enabled direct comparison of seven segments of proximal and mid-coronary artery for each patient by two blinded assessors. Each segment of coronary artery from the multislice CT image was evaluated initially for 'assessability' and those segments deemed assessable were subsequently investigated for the presence or absence of a significantly (n=70%) stenotic lesion. RESULTS: Overall 68% of proximal and mid-coronary artery segments were assessable. The sensitivity and specificity of four-slice CT coronary angiography in assessable segments for detecting the presence or absence (n=70%) of stenoses were 72 and 86%, respectively. These results correspond to a positive predictive value of 53% and a 93% negative predictive value. If the 32% of non-assessable segments are added into the calculation then the sensitivity and specificity fall to 49 and 66%, respectively. CONCLUSION: Although multislice CT coronary angiography is a promising technique, the overall assessability and diagnostic accuracy of four-slice CT acquisition is not sufficient to justify routine clinical use. Further, evaluation should investigate the benefit of the reduction in temporal and spatial resolution offered by 16 and 32 slice acquisition

  20. Usefulness of detecting atherosclerosis by computed tomography. A relation to coronary artery stenosis

    International Nuclear Information System (INIS)

    Takasu, Junichiro; Yamamoto, Rie; Yokoyama, Kenichi

    1999-01-01

    Reports evaluating coronary artery calcification detection by nonenhanced computed tomography (CT) have verified the usefulness for diagnosis of coronary artery disease. In the condition of a mobile CT scanning at a public health examination, however, determination of coronary calcification remains unclear. We investigated, under this scanning condition, a relation between the characteristic of coronary artery calcification determined by conventional CT and coronary disease on arteriogram. The quantification of aortic wall thickening by enhanced CT was examined on the usefulness of detecting coronary artery disease. The CT density score and the characteristics of aortic atherosclerosis for 159 male patients 30 year-old or more (average age 60.7 years) were examined the relation to coronary artery stenoses. The CT density score was the strongest independent variable for determining the existence of coronary disease. The CT density cutoff score for detection of coronary disease was 50 equal to 50 HU the maximal CT density in the coronary arteries. The maximal aortic wall thickness was the strongest significant variable independent of the noted coronary risk factors for the severity of coronary stenosis on arteriogram. (author)

  1. Prevalence of stenoses and occlusions of brain-supplying arteries in young stroke patients.

    LENUS (Irish Health Repository)

    von Sarnowski, Bettina

    2013-03-06

    OBJECTIVE: Atherosclerosis is believed to be a minor cause of TIA and stroke in younger and middle-aged patients. However, data from large cohorts are limited. This study investigates the prevalence of extracranial and intracranial atherosclerosis in stroke and TIA patients aged 18-55 years in the multinational sifap1 study. METHODS: From the sifap1 cohort (n = 5,023), we analyzed a subset of patients with complete data from carotid ultrasound studies. Patients with arterial dissections, vasculitis, and mobile thrombi were excluded. Among the remaining 2,187 patients (men: n = 1,319; 18-44 years: n = 744), intracranial arteries were additionally examined with ultrasonography in 1,612 patients (73.7%). Patients were stratified by sex and age groups (younger: 18-44 years; middle-aged: 45-55 years). RESULTS: In patients with ischemic stroke, the overall prevalence of carotid artery stenoses and occlusions was 8.9% (younger: 4.9%; middle-aged: 11.0%), of which 81% were symptomatic. Nonstenotic carotid plaques were more common in men than in women (15.8% vs 7.7%; p < 0.001), and in middle-aged than in younger patients (17.0% vs 4.9%; p < 0.001). Supratentorial intracranial artery stenoses and occlusions amounted to 11.8%. Supratentorial stenoses occurred more frequently in middle-aged patients (13.0% vs 7.8%; p < 0.001), whereas occlusions were equally common (both 3.2%; not significant). CONCLUSIONS: We observed a substantial proportion of atherosclerotic carotid artery stenoses and occlusions in younger stroke patients. Intracranial stenoses and occlusions were even more prevalent than extracranial carotid artery disease. Together with nonstenotic plaques, one-fifth of patients (21.2%) had symptomatic or asymptomatic large-artery atherosclerosis, which should encourage future stroke prevention campaigns to target risk factor modification in young people.

  2. Functional and quantitative magnetic resonance myelography of symptomatic stenoses of the lumbar spine

    Energy Technology Data Exchange (ETDEWEB)

    Eberhardt, Knut [District Hospital Castle of Werneck, MRI Center of Excellence, Werneck (Germany); Ganslandt, Oliver [University of Erlangen-Nuremberg, Department of Neurosurgery, Erlangen (Germany); Stadlbauer, Andreas [University of Erlangen-Nuremberg, Department of Neurosurgery, Erlangen (Germany); Medical University Vienna, Department of Radiology and Nuclear Medicine, Vienna (Austria)

    2014-12-15

    The objective of this study was to demonstrate that functional, quantitative magnetic resonance myelography (MRM) allows standardized diagnosis of symptomatic lumbar spinal stenoses which show at least equal detectability compared to functional myelography and postmyelographic CT (pmCT) based on intra- and postoperative findings. We investigated 43 volunteers and 47 patients with symptomatic lumbar spinal stenoses using MRM in normal position as well as in flexion and extension in a standard whole-body MR scanner. Twenty volunteers were additionally examined under axial loading. All patients were investigated by functional myelography and pmCT and 10 patients had a functional lumbar MRM postoperatively. Range of motion and cerebrospinal fluid (CSF) volumes in normal position, flexion, extension, and under axial loading (volunteers) were assessed for each segment. Detectability was determined by using intraoperative findings, and postoperative freedom of symptoms was correlated with CSF volume changes in MRM. The ranges of motion in a standard whole-body MR scanner provide adequate scope for investigations into function (flexion and extension) in both volunteers and patients. Axial loading was associated with a mechanism of extension, albeit to a far smaller extent. Detectability of lumbar stenoses was 100 % for MRM, 58 % for conventional myelography, and 68 % for pmCT. Postoperative changes in CSF volume of levels with stenoses in MRM strongly correlated with freedom of symptoms (R = 0.772). This MRM method allows for exact diagnosis and reproducible quantification of stenoses, motion-related changes, and spondylolistheses of the lumbar spine. It may be useful for early detection of alterations in order to avoid neuronal compression. (orig.)

  3. Clinical performance of dual-source computerized tomography (DSCT) in primary diagnostics of coronary heart diseases

    International Nuclear Information System (INIS)

    Brunner, H.; Froehner, S.; Wagner, M.; Schmitt, R.; Brunn, J.; Gietzen, F.H.; Kerber, S.

    2008-01-01

    Dual-source-CT-technology (DSCT) improves temporal resolution of cardiac computed tomography to 83 ms per heart-phase. In this study, the clinical performance of this new method is evaluated. Materials and Methods: In fifty patients (33 male, 17 female; age 50±13 years) with suspected coronary heart disease, CT angiography (slice thickness 0,75 mm, contrast-agent 60-80 ml iomeprol) was performed with a Somatom Definition scanner. Based on the coronary 15-segment-model of the AHA, scores for image quality and lumen reduction were established to enable the observer, to give recommendations for further therapy. Results: Out of 750 possible AHA-segments, 655 were depicted (87,3%). 591 segments (90,2%) were assessed without any limitation of quality, 49 (7,5%) segments showed moderate, and 15 (2,3%) segments severe limitation in image quality. 508 (77,6%) segments were without pathological findings, 92 (14,0%) segments had minimal atherosclerotic lesions, 42 (6,4%) segments suffered from stenoses with lumen reduction less than 70%, and 13 (2,0%) showed significant stenoses of more than 70%. In 31 patients (62%), coronary heart disease was ruled out by CT angiography without any need for further non-invasive or invasive diagnostics. 8 patients (16%) underwent stress-testing for ischemia. In 11 (22%) patients coronary angiography was recommended, and DSCT findings were confirmed in 10 cases. Only one LCx stenosis was overestimated in DSCT. Conclusion: Contrast-enhanced DSCT is a powerful tool in diagnosis of coronary heart disease. 98% of coronary segments could be assessed in diagnostic quality, and at least 90% of haemodynamically significant coronary stenoses were detected. (orig.)

  4. A novel patient-specific model to compute coronary fractional flow reserve.

    Science.gov (United States)

    Kwon, Soon-Sung; Chung, Eui-Chul; Park, Jin-Seo; Kim, Gook-Tae; Kim, Jun-Woo; Kim, Keun-Hong; Shin, Eun-Seok; Shim, Eun Bo

    2014-09-01

    The fractional flow reserve (FFR) is a widely used clinical index to evaluate the functional severity of coronary stenosis. A computer simulation method based on patients' computed tomography (CT) data is a plausible non-invasive approach for computing the FFR. This method can provide a detailed solution for the stenosed coronary hemodynamics by coupling computational fluid dynamics (CFD) with the lumped parameter model (LPM) of the cardiovascular system. In this work, we have implemented a simple computational method to compute the FFR. As this method uses only coronary arteries for the CFD model and includes only the LPM of the coronary vascular system, it provides simpler boundary conditions for the coronary geometry and is computationally more efficient than existing approaches. To test the efficacy of this method, we simulated a three-dimensional straight vessel using CFD coupled with the LPM. The computed results were compared with those of the LPM. To validate this method in terms of clinically realistic geometry, a patient-specific model of stenosed coronary arteries was constructed from CT images, and the computed FFR was compared with clinically measured results. We evaluated the effect of a model aorta on the computed FFR and compared this with a model without the aorta. Computationally, the model without the aorta was more efficient than that with the aorta, reducing the CPU time required for computing a cardiac cycle to 43.4%. Copyright © 2014. Published by Elsevier Ltd.

  5. Coronary CT angiography using prospective ECG triggering. High diagnostic accuracy with low radiation dose

    International Nuclear Information System (INIS)

    Arnoldi, E.; Ramos-Duran, L.; Abro, J.A.; Costello, P.; Zwerner, P.L.; Schoepf, U.J.; Nikolaou, K.; Reiser, M.F.

    2010-01-01

    The purpose of this study was to evaluate the diagnostic performance of coronary CT angiography (coronary CTA) using prospective ECG triggering (PT) for the detection of significant coronary artery stenosis compared to invasive coronary angiography (ICA). A total of 20 patients underwent coronary CTA with PT using a 128-slice CT scanner (Definition trademark AS+, Siemens) and ICA. All coronary CTA studies were evaluated for significant coronary artery stenoses (≥50% luminal narrowing) by 2 observers in consensus using the AHA-15-segment model. Findings in CTA were compared to those in ICA. Coronary CTA using PT had 88% sensitivity in comparison to 100% with ICA, 95% to 88% specificity, 80% to 92% positive predictive value and 97% to 100% negative predictive value for diagnosing significant coronary artery stenosis on per segment per patient analysis, respectively. Mean effective radiation dose-equivalent of CTA was 2.6±1 mSv. Coronary CTA using PT enables non-invasive diagnosis of significant coronary artery stenosis with high diagnostic accuracy in comparison to ICA and is associated with comparably low radiation exposure. (orig.) [de

  6. Extracellular Vesicles in Bile as Markers of Malignant Biliary Stenoses.

    Science.gov (United States)

    Severino, Valeria; Dumonceau, Jean-Marc; Delhaye, Myriam; Moll, Solange; Annessi-Ramseyer, Isabelle; Robin, Xavier; Frossard, Jean-Louis; Farina, Annarita

    2017-08-01

    Algorithms for diagnosis of malignant common bile duct (CBD) stenoses are complex and lack accuracy. Malignant tumors secrete large numbers of extracellular vesicles (EVs) into surrounding fluids; EVs might therefore serve as biomarkers for diagnosis. We investigated whether concentrations of EVs in bile could discriminate malignant from nonmalignant CBD stenoses. We collected bile and blood samples from 50 patients undergoing therapeutic endoscopic retrograde cholangiopancreatography at university hospitals in Europe for CBD stenosis of malignant (pancreatic cancer, n = 20 or cholangiocarcinoma, n = 5) or nonmalignant (chronic pancreatitis [CP], n = 15) origin. Ten patients with CBD obstruction due to biliary stones were included as controls. EV concentrations in samples were determined by nanoparticle tracking analyses. The discovery cohort comprised the first 10 patients with a diagnosis of pancreatic cancer, based on tissue analysis, and 10 consecutive controls. Using samples from these subjects, we identified a threshold concentration of bile EVs that could best discriminate between patients with pancreatic cancer from controls. We verified the diagnostic performance of bile EV concentration by analyzing samples from the 30 consecutive patients with a diagnosis of malignant (pancreatic cancer or cholangiocarcinoma, n = 15) or nonmalignant (CP, n = 15) CBD stenosis. Samples were compared using the Mann-Whitney test and nonparametric Spearman correlation analysis. Receiver operating characteristic area under the curve was used to determine diagnostic accuracy. In both cohorts, the median concentration of EVs was significantly higher in bile samples from patients with malignant CBD stenoses than controls or nonmalignant CBD stenoses (2.41 × 10 15 vs 1.60 × 10 14 nanoparticles/L in the discovery cohort; P bile best distinguished patients with malignant CBD from controls in the discovery cohort. In the verification cohort, this threshold discriminated

  7. Comparison of multi-slice CT (MSCT) and TI-201 myocardial SPECT in detection of coronary artery disease: relation to coronary arteriography

    Energy Technology Data Exchange (ETDEWEB)

    Pai, M. S.; Kim, Y. K.; Shim, S. S. [College of Medicine, Univ. of Ewha Womens, Seoul (Korea, Republic of)

    2003-07-01

    To evaluate the diagnostic potentials of MSCT and TI-201 SPECT in the assessment of coronary artery disease. Twenty-four patients (15 men, 9 women, 42-79 years) with clinically suspected coronary artery disease were studied by TI-201 myocardial SPECT and MSCT. MSCT data were obtained with 12 x 0.75 mm, 420ms rotation, multi-slice CT scanner (SOMATOM Sensation, Siemens) using non-ionic contrast, 80ml, 4ml/sec. Multiplanar reconstruction techniques were used for evaluation of coronary arteries. TI-201 myocardial SPECT were performed at stress with adenosine and at rest. Data from MSCT and TI-201 SPECT were compared territory by territory (divided into two segments; LAD and RCA/LCx) and related to coronary arteriography, in which more than 60% stenoses are regarded as significant. MSCT and TI-201 SPECT showed agreement in 37 out of 48 segments (77.1%). Out of 11 disagreed segments (22.9), TI-201 SPECT was superior in 6 segments and MSCT was superior in 5 segments. Sensitivities and specificities of MSCT and TI-201 SPECT by coronary arteriography are 81.8%, 69.2% and 86.3%, 76.9%, respectively. Agreed 4 segments between MSCT and TI-201 SPECT exhibited results that differ from the results of coronary arteriography. Myocardial bridge in two cases were detected as significant stenoses by MSCT but showed normal perfusion in TI-201 SPECT. Agreement between MSCT and TI-201 SPECT in the assessment of coronary artery disease was good but TI-201 SPECT has higher sensitivity and specificity for the detection of jeopardized myocardium than MSCT. MSCT and TI-201 SPECT provide complementary information in the assessment of coronary artery disease and could help reduce probable mistake in the interpretation of hemo dynamically insignificant lesion in coronary arteriography.

  8. Successful percutaneous stenting of a right gastroepiploic coronary bypass graft using monorail delivery system: a case report.

    Science.gov (United States)

    Alam, M; Safi, A M; Mandawat, M K; Anderson, J E; Kwan, T; Feit, A; Clark, L T

    2000-02-01

    The right gastroepiploic artery (RGEA) is being successfully used as an arterial conduit in a selected group of patients undergoing coronary artery bypass graft surgery. However, myocardial ischemia may result due to spasm, occlusion, and stenosis of this graft. The anastamosis site at distal right coronary artery (RCA) or posterior descending artery (PDA) is the most common location for stenosis of an in situ gastroepiploic coronary bypass graft. Balloon angioplasty of such stenoses has been reported with optimal short-term results. Stent deployment would decrease the restenosis rate, so that repeat procedures could be minimized for these technically challenging lesions. We describe a case of successful deployment of a stent with monorail delivery system at the anastamotic site stenosis of an in situ gastroepiploic right coronary artery bypass graft. This percutaneous coronary intervention could prevent redo coronary artery bypass graft surgery. Cathet. Cardiovasc. Intervent. 49:197-199, 2000. Copyright 2000 Wiley-Liss, Inc.

  9. Association between smoking habits and severity of coronary stenosis as assessed by coronary computed tomography angiography.

    Science.gov (United States)

    Yano, Masaya; Miura, Shin-Ichiro; Shiga, Yuhei; Miyase, Yuiko; Suematsu, Yasunori; Norimatsu, Kenji; Nakamura, Ayumi; Adachi, Sen; Nishikawa, Hiroaki; Saku, Keijiro

    2016-07-01

    Smoking promotes arteriosclerosis and is one of the most important coronary risk factors. However, few studies have investigated the association between smoking habits and the severity of coronary stenosis as assessed by coronary computed tomography angiography (CTA). We enrolled 416 patients [165/251 = smoker (past and current)/non-smoker)]. They had all undergone CTA and either were clinically suspected of having coronary artery disease (CAD) or had at least one cardiovascular risk factor. We divided the patients into smoking and non-smoking groups, and evaluated the presence of CAD, the number of significantly stenosed coronary vessels (VD), and the Gensini score as assessed by CTA in the two groups. The incidence of CAD, VD, the Gensini score, and coronary calcification score in the smoking group were all significantly greater than those in the non-smoking group (CAD, p = 0.009; VD, p = 0.003; Gensini score, p = 0.007; coronary calcification score, p = 0.01). Pack-year was significantly associated with VD and the Gensini score, and was strongly associated with multi-vessel disease (2- and 3-VD) (p < 0.05), whereas the duration of cessation in past smokers was not associated with VD or the Gensini score. Pack-year, but not the duration of cessation, may be the most important factor that was associated with the severity of coronary stenosis in terms of VD and the Gensini score.

  10. Three-dimensional coronary MR angiography with continuous administration of Gd-DTPA. Delineation and detection of coronary artery stenosis

    International Nuclear Information System (INIS)

    Yokoyama, Kenichi

    1999-01-01

    Three-dimensional coronary MR angiography (3D coronary MRA) with Gd-DTPA administration was performed in 19 patients to evaluate the vascular delineation and diagnostic capability for stenotic lesions. A 3D fast low-angle shot (FLASH) with a navigator echo respiratory gating technique was used with a superconducting 1.5 tesla MR system (Vision, Siemens Medical Systems, Erlangen, Germany). Administration of the conventional T 1 contrast agent with extra-cellular distribution produced a significant increase in the SNR and CNR of the proximal coronary arterial images. Visual score of both the source images and the multiplanar reconstruction (MPR) images assessed by three radiologists was superior to those on control images (without contrast enhancement). The MRA findings of stenotic lesions of the coronary artery were compared with the results of the conventional coronary angiographic study. Overall sensitivity and specificity for the detection of stenosis were almost the same as those of control images. In conclusion, 3D coronary MRA with Gd-DTPA administration improved coronary artery delineation. However, further technical improvements are required to enhance the value of the technique in detecting stenoses. (author)

  11. 320-row CT coronary angiography predicts freedom from revascularisation and acts as a gatekeeper to defer invasive angiography in stable coronary artery disease: a fractional flow reserve-correlated study

    International Nuclear Information System (INIS)

    Ko, Brian S.; Wong, Dennis T.L.; Cameron, James D.; Leung, Michael; Meredith, Ian T.; Nerlekar, Nitesh; Antonis, Paul; Harper, Richard; Malaiapan, Yuvaraj; Seneviratne, Sujith K.; Leong, Darryl P.; Crossett, Marcus; Troupis, John

    2014-01-01

    To determine the accuracy of 320-row multidetector coronary computed tomography angiography (M320-CCTA) to detect functional stenoses using fractional flow reserve (FFR) as the reference standard and to predict revascularisation in stable coronary artery disease. One hundred and fifteen patients (230 vessels) underwent M320-CCTA and FFR assessment and were followed for 18 months. Diameter stenosis on invasive angiography (ICA) and M320-CCTA were assessed by consensus by two observers and significant stenosis was defined as ≥50 %. FFR ≤0.8 indicated functionally significant stenoses. M320-CCTA had 94 % sensitivity and 94 % negative predictive value (NPV) for FFR ≤0.8. Overall accuracy was 70 %, specificity 54 % and positive predictive value 65 %. On receiver operating characteristic (ROC) curve analysis, the area under the curve (AUC) for CCTA to predict FFR ≤0.8 was 0.74 which was comparable with ICA. The absence of a significant stenosis on M320-CCTA was associated with a 6 % revascularisation rate. M320-CCTA predicted revascularisation with an AUC of 0.71 which was comparable with ICA. M320-CCTA has excellent sensitivity and NPV for functional stenoses and therefore may act as an effective gatekeeper to defer ICA and revascularisation. Like ICA, M320-CCTA lacks specificity for functional stenoses and only has moderate accuracy to predict the need for revascularisation. (orig.)

  12. Myocardial perfusion scintigraphy in identification and localization of individual coronary lesions

    Directory of Open Access Journals (Sweden)

    Baškot Branislav

    2004-01-01

    Full Text Available The aim of this study was to evaluate the accuracy of myocardial perfusion scintigraphy with technetium-99m tetrofosmin by single-photon emission computed tomography (SPECT, using one-day protocol in the identification and localization of individual stenosed coronary vessels. Sixty-eight patients with suspected coronary artery disease (CAD were studied. In thirty of them coronary angiography showed significant stenosis (³50%. Nine patients were with one-vessel disease, 11 were with two-vessel disease, and 10 were with three-vessel disease. All the patients were administered two i.v. injections of 99mTc tetrofosmin, one at peak pharmacologic exercise (1-3 min after i.v. administration of dipiridamol 0.56 mg per kg during 4 min 370 MBq, and the other 740 MBq at rest 3 hrs after the exercise test (acquisition was obtained 15-30 min after injections for both studies. Overall sensitivity, specificity, and diagnostic accuracy in the identification of individual stenosed coronary vessels were 90%, 86%, and 88%, respectively. Sensitivity, specificity, and accuracy in each of the individual vascular territories were not significantly different: LAD (96% 64%, and 75%, ACx (73%, 100%, and 94%, RCA (95%, 93%, and 94%. The results of this study demonstrated one-day 99mTc-tetrofosmin SPECT scintigraphy to be suitable and accurate technique for the identification and localization of individual stenosed coronary vessels, as well as a highly sensitive method in the recognition of one- and multiple-vessel diseases of coronary arteries.

  13. Baseline Glutathione Peroxidase Activity Affects Prognosis after Acute Coronary Syndromes

    OpenAIRE

    García-Pinilla, José Manuel; Gálvez, Julio; Cabrera-Bueno, Fernando; Jiménez-Navarro, Manuel; Gómez-Doblas, Juan José; Galisteo, Milagros; Camuesco, Desiré; de Teresa Galván, Carlos; Espinosa-Caliani, Salvador; Zarzuelo, Antonio; de Teresa-Galván, Eduardo

    2008-01-01

    Oxidative stress is associated with atherosclerosis and plaque lesions in experimental in vitro models. Few in vivo studies have examined the association between redox status and the prognosis of acute coronary syndromes.

  14. [The efficacy of endoscopic endosonography in diagnosis of benign and malignant stenoses of common bile duct].

    Science.gov (United States)

    Solodinina, E N; Starkov, Iu G; Shumkina, L V

    2016-01-01

    To define criteria and to estimate diagnostic significance of endosonography in differential diagnosis of benign and malignant stenoses of common bile duct. We presented the results of survey and treatment of 57 patients with benign and malignant stenoses of common bile duct. The technique of endosonography is described. We have formulated major criteria of differential diagnostics of tumoral and non-tumoral lesion of extrahepatic bile ducts. Comparative analysis of endosonography, ultrasound, computed tomography and magnetic resonance cholangiopancreatography was performed. Sensitivity, specificity and accuracy of endosonography in diagnosis of stenosis cause is 97.7%, 100% and 98.2% respectively. So it exceeds the efficacy of other diagnostic X-ray methods. In modern surgical clinic endosonography should be mandatory performed. It is necessary for final diagnostics of cause of common bile duct stenosis especially in case of its low location.

  15. Extracellular Vesicles in Bile as Markers of Malignant Biliary Stenoses

    DEFF Research Database (Denmark)

    Severino, Valeria; Dumonceau, Jean Marc; Delhaye, Myriam

    2017-01-01

    Background & Aims Algorithms for diagnosis of malignant common bile duct (CBD) stenoses are complex and lack accuracy. Malignant tumors secrete large numbers of extracellular vesicles (EVs) into surrounding fluids; EVs might therefore serve as biomarkers for diagnosis. We investigated whether...... concentrations of EVs in bile could discriminate malignant from nonmalignant CBD stenoses. Methods We collected bile and blood samples from 50 patients undergoing therapeutic endoscopic retrograde cholangiopancreatography at university hospitals in Europe for CBD stenosis of malignant (pancreatic cancer, n = 20...... with a diagnosis of pancreatic cancer, based on tissue analysis, and 10 consecutive controls. Using samples from these subjects, we identified a threshold concentration of bile EVs that could best discriminate between patients with pancreatic cancer from controls. We verified the diagnostic performance of bile EV...

  16. Coronary CT angiography-derived fractional flow reserve correlated with invasive fractional flow reserve measurements - initial experience with a novel physician-driven algorithm

    International Nuclear Information System (INIS)

    Baumann, Stefan; Wang, Rui; Schoepf, U.J.; Steinberg, Daniel H.; Spearman, James V.; Bayer, Richard R.; Hamm, Christian W.; Renker, Matthias

    2015-01-01

    The present study aimed to determine the feasibility of a novel fractional flow reserve (FFR) algorithm based on coronary CT angiography (cCTA) that permits point-of-care assessment, without data transfer to core laboratories, for the evaluation of potentially ischemia-causing stenoses. To obtain CT-based FFR, anatomical coronary information and ventricular mass extracted from cCTA datasets were integrated with haemodynamic parameters. CT-based FFR was assessed for 36 coronary artery stenoses in 28 patients in a blinded fashion and compared to catheter-based FFR. Haemodynamically relevant stenoses were defined by an invasive FFR ≤0.80. Time was measured for the processing of each cCTA dataset and CT-based FFR computation. Assessment of cCTA image quality was performed using a 5-point scale. Mean total time for CT-based FFR determination was 51.9 ± 9.0 min. Per-vessel analysis for the identification of lesion-specific myocardial ischemia demonstrated good correlation (Pearson's product-moment r = 0.74, p < 0.0001) between the prototype CT-based FFR algorithm and invasive FFR. Subjective image quality analysis resulted in a median score of 4 (interquartile ranges, 3-4). Our initial data suggest that the CT-based FFR method for the detection of haemodynamically significant stenoses evaluated in the selected population correlates well with invasive FFR and renders time-efficient point-of-care assessment possible. (orig.)

  17. Standardized evaluation framework for evaluating coronary artery stenosis detection, stenosis quantification and lumen segmentation algorithms in computed tomography angiography.

    Science.gov (United States)

    Kirişli, H A; Schaap, M; Metz, C T; Dharampal, A S; Meijboom, W B; Papadopoulou, S L; Dedic, A; Nieman, K; de Graaf, M A; Meijs, M F L; Cramer, M J; Broersen, A; Cetin, S; Eslami, A; Flórez-Valencia, L; Lor, K L; Matuszewski, B; Melki, I; Mohr, B; Oksüz, I; Shahzad, R; Wang, C; Kitslaar, P H; Unal, G; Katouzian, A; Örkisz, M; Chen, C M; Precioso, F; Najman, L; Masood, S; Ünay, D; van Vliet, L; Moreno, R; Goldenberg, R; Vuçini, E; Krestin, G P; Niessen, W J; van Walsum, T

    2013-12-01

    Though conventional coronary angiography (CCA) has been the standard of reference for diagnosing coronary artery disease in the past decades, computed tomography angiography (CTA) has rapidly emerged, and is nowadays widely used in clinical practice. Here, we introduce a standardized evaluation framework to reliably evaluate and compare the performance of the algorithms devised to detect and quantify the coronary artery stenoses, and to segment the coronary artery lumen in CTA data. The objective of this evaluation framework is to demonstrate the feasibility of dedicated algorithms to: (1) (semi-)automatically detect and quantify stenosis on CTA, in comparison with quantitative coronary angiography (QCA) and CTA consensus reading, and (2) (semi-)automatically segment the coronary lumen on CTA, in comparison with expert's manual annotation. A database consisting of 48 multicenter multivendor cardiac CTA datasets with corresponding reference standards are described and made available. The algorithms from 11 research groups were quantitatively evaluated and compared. The results show that (1) some of the current stenosis detection/quantification algorithms may be used for triage or as a second-reader in clinical practice, and that (2) automatic lumen segmentation is possible with a precision similar to that obtained by experts. The framework is open for new submissions through the website, at http://coronary.bigr.nl/stenoses/. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. PTA and Stenting of Benign Venous Stenoses in the Pelvis: Long-Term Results

    International Nuclear Information System (INIS)

    Wohlgemuth, Walter A.; Weber, Hermann; Loeprecht, Henning; Tietze, Wolfram; Bohndorf, Klaus

    2000-01-01

    Purpose: To provide follow-up data on endovascular intervention for venous stenoses in the pelvis.Methods: Between 1985 and 1995, 35 patients presented with 42 stenoses of the pelvic veins after operative thrombectomy and creation of an arteriovenous fistula, combined with intraoperative venous angioscopy. All patients underwent angioplasty and, if unsuccessful, percutaneous insertion of an endovascular stent (n = 7).Results: Angioplasty with and without endovascular stenting was technically successful in 34 of 35 patients (97%). Average length of the stenoses was 20.6 mm (range 10-90 mm), average diameter before dilation 4.1 mm (range 2-6 mm), and average diameter after dilation 10.1 mm (range 5-18 mm). Intraoperative angioscopy showed pathologic findings (intimal laceration or residual thrombotic material) in 14 patients. After an average follow-up period of 4.13 years, 24 (69%) patients had patent veins. The difference in the primary patency rate between patients with angioscopically abnormal veins (6 of 14 patients, corresponding to a patency rate of 43%) and patients with angioscopically normal veins after thrombectomy (18 of 21 patients, corresponding to a patency rate of 86%) was statistically significant (p < 0.01, log rank test).Conclusions: Percutaneous transluminal angioplasty and/or stenting are good treatment modalities for pelvic vein stenosis following surgical thrombectomy. Angioscopically abnormal veins have a poorer long-term patency, regardless of the type of intervention

  19. Coronary angioplasty with second generation Monorail catheters.

    Science.gov (United States)

    Pande, A K; Meier, B; Urban, P; Villavicencio, R; de la Serna, F; Moles, V

    1991-07-01

    The Monorail system (Schneider) consists of a balloon catheter in which the guidewire passes through the balloon itself, exits the catheter proximal to the balloon, and runs alongside its small shaft (3 French) through the length of the guiding catheter. It offers distinct advantages over conventional systems of coronary angioplasty. It facilitates contrast injections and permits rapid balloon exchanges. This system was used for coronary angioplasty in 273 unselected consecutive patients (age 59 +/- 10, mean 35 to 73 years). There were 216 patients (84%) undergoing single-vessel and 57 patients (16%) with multi-vessel coronary angioplasty. A total of 335 coronary stenoses were dilated, which included 35 total occlusions. The size of balloon used ranged from 2.0 to 4.25 mm (3.0 +/- 0.5 mm) and the severity of stenosis was 85 +/- 11%. Technical success was defined as a residual stenosis of less than 50% as determined angiographically. Clinical success was defined as technical success, and absence of a major inhospital complication defined as absence of myocardial infarction, lack of need for coronary arterial bypass surgery, and survival. The Monorail system was technically successful in 294/300 stenotic lesions (98%). It was clinically successful for 281 lesions (94%). Of the 35 total occlusions, technical success was obtained in 25 (71%). The residual stenosis of successful cases was 26 +/- 21%. The Monorail system was also successful in 5 patients with stenosis of more than 90% in whom conventional systems failed. The complications included acute occlusion causing acute myocardial infarction in 13 cases (5%), emergency coronary arterial bypass surgery in 1 patient (0.4%), and death in 4 patients (1.5%).(ABSTRACT TRUNCATED AT 250 WORDS)

  20. Quantitative thallium-201 single-photon emission computed tomography during maximal pharmacologic coronary vasodilation with adenosine for assessing coronary artery disease

    International Nuclear Information System (INIS)

    Nishimura, S.; Mahmarian, J.J.; Boyce, T.M.; Verani, M.S.

    1991-01-01

    The diagnostic value of maximal pharmacologic coronary vasodilation with intravenously administered adenosine in conjunction with thallium-201 single-photon emission computed tomography (SPECT) for detection of coronary artery disease was investigated in 101 consecutive patients who had concomitant coronary arteriography. Tomographic images were assessed visually and from computer-quantified polar maps of the thallium-201 distribution. Significant coronary artery disease, defined as greater than 50% luminal diameter stenosis, was present in 70 patients. The sensitivity for detecting patients with coronary artery disease using quantitative analysis was 87% in the total group, 82% in patients without myocardial infarction and 96% in those with prior myocardial infarction; the specificity was 90%. The sensitivity for diagnosing coronary artery disease in patients without infarction with single-, double-and triple-vessel disease was 76%, 86% and 90%, respectively. All individual stenoses were identified in 68% of patients with double-vessel disease and in 65% of those with triple-vessel disease. The extent of the perfusion defects, as quantified by polar maps, was directly related to the extent of coronary artery disease. In conclusion, quantitative thallium-201 SPECT during adenosine infusion has high sensitivity and specificity for diagnosing the presence of coronary artery disease, localizing the anatomic site of coronary stenosis and identifying the majority of affected vascular regions in patients with multivessel involvement

  1. Radiation exposure to patient's skin during percutaneous coronary intervention for various lesions, including chronic total occlusion

    International Nuclear Information System (INIS)

    Suzuki, Shigeru; Furui, Shigeru; Kohtake, Hiroshi; Yokoyama, Naoyuki; Kozuma, Ken; Yamamoto, Yoshito; Isshiki, Takaaki

    2006-01-01

    Radiation skin injuries have been reported as a result of various procedures, so in the present study the patients' entrance skin dose (ESD) during percutaneous coronary intervention (PCI) was evaluated. ESDs were assessed during 97 procedures (13 for chronic total occlusion (CTO), 14 for multivessel stenoses, 22 for single-vessel multiple stenoses, and 48 for single stenosis). The patients wore jackets that had 48 or 52 radiosensitive indicators placed on the back during the PCI procedures, with 8 other indicators placed on both upper arms. After the procedure, the color of the indicators was analyzed with a color measuring instrument, and the patients' ESDs were calculated from the color difference of the indicators. The average maximum ESDs of the patients were 4.5±2.8 Gy (median: 4.6 Gy) for CTO, 2.3±0.7 Gy (median: 2.4 Gy) for multi-vessel stenoses, 1.8±1.0 Gy (median: 1.5 Gy) for single-vessel multiple stenoses, and 1.4±0.9 Gy (median: 1.2 Gy) for single stenosis. Skin injury can occur during PCI, especially for CTO, so it is important to estimate each patient's ESD and attempt to reduce it. (author)

  2. Effect of Heart Rate and Coronary Calcification on the Diagnostic Accuracy of the Dual-Source CT Coronary Angiography in Patients with Suspected Coronary Artery Disease

    International Nuclear Information System (INIS)

    Meng, Lingdong; Cui, Lianqun; Cheng, Yuntao; Wu, Xiaoyan; Tang, Yuansheng; Wang, Yong; Xu, Fayun

    2009-01-01

    To evaluate the diagnostic accuracy of a dual-source computed tomography (DSCT) coronary angiography, with a particular focus on the effect of heart rate and calcifications. One hundred and nine patients with suspected coronary disease were divided into 2 groups according to a mean heart rate ( 400). Next, the effect of heart rate and calcification on the accuracy of coronary artery stenosis detection was analyzed by using an invasive coronary angiography as a reference standard. Coronary segments of less than 1.5 mm in diameter in an American Heart Association (AHA) 15-segment model were independently assessed. The mean heart rate during the scan was 71.8 bpm, whereas the mean Agatston score was 226.5. Of the 1,588 segments examined, 1,533 (97%) were assessable. A total of 17 patients had calcium scores above 400 Agatston U, whereas 50 had heart rates ≥ 70 bpm. Overall the sensitivity, specificity, positive predictive values (PPV) and negative predictive values (NPV) for significant stenoses were: 95%, 91%, 65%, and 99% (by segment), respectively and 97%, 90%, 81%, and 91% (by artery), respectively (n = 475). Heart rate showed no significant impact on lesion detection; however, vessel calcification did show a significant impact on accuracy of assessment for coronary segments. The specificity, PPV and accuracy were 96%, 80%, and 96% (by segment), respectively for an Agatston score less than 100% and 99%, 96% and 98% (by artery). For an Agatston score of greater to or equal to 400 the specificity, PPV and accuracy were reduced to 79%, 55%, and 83% (by segment), respectively and to 79%, 69%, and 85% (by artery), respectively. The DSCT provides a high rate of accuracy for the detection of significant coronary artery disease, even in patients with high heart rates and evidence of coronary calcification. However, patients with severe coronary calcification (> 400 U) remain a challenge to diagnose

  3. [The role of epicardial fat and obesity parameters in the prediction of coronary heart disease].

    Science.gov (United States)

    Prídavková, Dana; Kantárová, Daniela; Lišková, Renáta; Červeň, Peter; Kovář, František; Mokáň, Marián

    2016-04-01

    To assess the relationship of parameters of obesity in relationship to coronary angiography findings with correlation of epicardial fat (EF) thickness in uppermentioned context. There were 80 patients examined (43 males, 37 postmenopausal females) undergoing elective coronary angiography. We examined the regular obesity parameters - BMI, waist circumference (WC), neck circumference (NC), total body fat (TBF), and visceral fat (VF) using bioimpedance. We assessed the echocardiographically measured EF thickness. We added examination of lipidogram, glycaemia, HOMA-IR (insulin resistance index) and AIP (aterogenic index of plasma). The set was divided into group with coronarographically proved stenosis or stenoses (withCS), and a group without finding of quantifiable stenosis or stenoses (withoutCS). The average thickness of EF in withCS group was 6.3 vs 5.6 mm in group withoutCS (p obesity parameters in assessment of pre-clinical stages of coronary atherosclerosis and prediction of risk of coronary heart disease. In adipose parameters, EF thickness was correlated the most by WC. Risk stratification of coronary artery disease is supplemented by increased HOMA-IR and AIP.

  4. Influence of radiographic contrast agents on quantitative coronary angiography

    International Nuclear Information System (INIS)

    Jost, Stefan; Hausmann, Dirk; Lippolt, Peter; Gerhardt, Uwe; Lichtlen, Paul R.

    1997-01-01

    Purpose. Quantitative angiographic studies on the vasomotility of epicardial coronary arteries are gaining increasing relevance. We investigated whether radiographic contrast agents might influence coronary vasomotor tone and thereby the results of such studies. Methods. Coronary angiograms were taken in 12 patients with coronary artery disease at intervals of 5, 3, 2, and 1 min with the low-osmolar, nonionic contrast agent iopamidol 300, and were repeated at identical intervals with the high-osmolar, ionic agent diatrizoate 76%. Results. Quantitative cine film analysis demonstrated no significant diameter changes in angiographically normal and stenotic coronary arteries with iopamidol. With diatrizoate, however, normal segments were dilated 2%±2% (p<0.01) after 2 min and 10%±3% after the 1 min interval (p<0.001). Stenoses showed no uniform responses to diatrizoate. Conclusion. Low-osmolar, nonionic contrast agents should be preferred for quantitative angiographic studies on epicardial coronary vasomotility. When using ionic contrast agents, injection intervals of at least 3 min are required

  5. Fractional flow reserve versus angiography for guidance of PCI in patients with multivessel coronary artery disease (FAME)

    DEFF Research Database (Denmark)

    van Nunen, Lokien X; Zimmermann, Frederik M; Tonino, Pim A L

    2015-01-01

    BACKGROUND: In the Fractional Flow Reserve Versus Angiography for Multivessel Evaluation (FAME) study, fractional flow reserve (FFR)-guided percutaneous coronary intervention (PCI) improved outcome compared with angiography-guided PCI for up to 2 years of follow-up. The aim in this study...... was to investigate whether the favourable clinical outcome with the FFR-guided PCI in the FAME study persisted over a 5-year follow-up. METHODS: The FAME study was a multicentre trial done in Belgium, Denmark, Germany, the Netherlands, Sweden, the UK, and the USA. Patients (aged ≥ 18 years) with multivessel coronary...... artery disease were randomly assigned to undergo angiography-guided PCI or FFR-guided PCI. Before randomisation, stenoses requiring PCI were identified on the angiogram. Patients allocated to angiography-guided PCI had revascularisation of all identified stenoses. Patients allocated to FFR-guided PCI had...

  6. Risk indicators in coronary cardiac disease and occlusive disease of the peripheral arteries

    International Nuclear Information System (INIS)

    Roth, H.

    1982-01-01

    In 160 patients with clinically confirmed coronary heart diseases, angiograms of the coronary vessels, the left ventricle, the abdominal aorta, the pelvic and femoral arteries and the supra-aortic vessels were taken. At the same time the incidence of the risk indicators overweight, hypercholesterinaemia, hypertriglyceridaemia, hyperuricaemia, diabetes mellitus, hypertension and cigarette smoking was established and compared with the angiograms. Hypercholesterinaemia, hypertriglyceridaemia, diabetes mellitus and hypertension are found to be in a clearly positive correlation with the frequency and severity of coronary and peripheral vascular diseases. For hyperuricaemia and overweight a relation to the frequency and severity of peripheral but not coronary vascular stenoses is outlined. Cigarette smoking, again, proves to be a clear risk indicator. (orig./MG) [de

  7. Transthoracic Doppler echocardiography – noninvasive diagnostic window for coronary flow reserve assessment

    Directory of Open Access Journals (Sweden)

    Dimitrow Paweł

    2003-04-01

    Full Text Available Abstract This review focuses on transthoracic Doppler echocardiography as noninvasive method used to assess coronary flow reserve (CFR in a wide spectrum of clinical settings. Transthoracic Doppler echocardiography is rapidly gaining appreciation as popular tool to measure CFR both in stenosed and normal epicardial coronary arteries (predominantly in left anterior descending coronary artery. Post-stenotic CFR measurement is helpful in: functional assessment of moderate stenosis, detection of significant or critical stenosis, monitoring of restenosis after revascularization. In the absence of stenosis in the epicardial coronary artery, decreased CFR enable to detect impaired microvascular vasodilatation in: reperfused myocardial infarct, arterial hypertension with or without left ventricular hypertrophy, diabetes mellitus, hypercholesterolemia, syndrome X, hypertrophic cardiomyopathy. In these diseases, noninvasive transthoracic Doppler echocardiography allows for serial CFR evaluations to explore the effect of various pharmacological therapies.

  8. Compensatory enlargement of the left main coronary artery: insights from the PROSPECT study.

    Science.gov (United States)

    Inaba, Shinji; Mintz, Gary S; Shimizu, Takehisa; Weisz, Giora; Mehran, Roxana; Marso, Steven P; Xu, Ke; de Bruyne, Bernard; Serruys, Patrick W; Stone, Gregg W; Maehara, Akiko

    2014-03-01

    Glagov proposed that remodeling delayed development of significant coronary artery stenoses until plaque occupied, on average, 40% of arterial area (40% plaque burden). The aim of the current study was to confirm the previously proposed concept of coronary remodeling as first described by Glagov who studied postmortem left main coronary arteries (LMCAs). Using the in-vivo intravascular ultrasound data from the Providing Regional Observations to Study Predictors of Events in the Coronary Tree (PROSPECT) study, we evaluated 552 LMCAs in 552 patients. External elastic membrane cross-sectional areas (CSAs) increased in proportion to the increase in plaque and media CSAs (r=0.61, P40% plaque burden), there was an inverse relationship between lumen CSA and plaque burden (r=-0.57, PPROSPECT study patients. In addition, the present study suggested that plaque phenotype worsened with increasing LMCA plaque growth.

  9. Women with acute coronary syndrome are less invasively examined and subsequently less treated than men

    DEFF Research Database (Denmark)

    Hvelplund, Anders; Galatius, Søren; Madsen, Mette

    2010-01-01

    AIMS: To investigate if gender bias is present in today's setting of an early invasive strategy for patients with acute coronary syndrome in Denmark (population 5 million). METHODS AND RESULTS: We identified all patients admitted to Danish hospitals with acute coronary syndrome in 2005-07 (9561...... women and 16 406 men). Cox proportional hazard models were used to estimate the gender differences in coronary angiography (CAG) rate and subsequent revascularization rate within 60 days of admission. Significantly less women received CAG (cumulative incidence 64% for women vs. 78% for men, P ....66-0.71, P coronary angiogram. However, after adjustment for the number of significant stenoses, age, and comorbidity women were still less likely to be revascularized (HR 0.91, 95% CI 0.87-0.95, P...

  10. Novel Approaches for the Use of Cardiac/Coronary Computed Tomography Angiography

    Directory of Open Access Journals (Sweden)

    Hadi Mirhedayati Roudsari, MD

    2016-12-01

    Full Text Available Recent developments in the novel imaging technology of cardiac computed tomography (CT not only permit detailed assessment of cardiac anatomy but also provide insight into cardiovascular physiology. Foremost, coronary CT angiography (CCTA enables direct noninvasive examination of both coronary artery stenoses and atherosclerotic plaque characteristics. Calculation of computational fluid dynamics by cardiac CT allows the noninvasive estimation of fractional flow reserve, which increases the diagnostic accuracy for detection of hemodynamically significant coronary artery disease. In addition, a combination of myocardial CT perfusion and CCTA can provide simultaneous anatomical and functional assessment of coronary artery disease. Finally, detailed anatomical evaluation of atrial, ventricular, and valvular anatomy provides diagnostic information and guidance for procedural planning, such as for transcatheter aortic valve replacement. The clinical applications of cardiac CT will be extended with the development of these novel modalities.

  11. Diagnostic accuracy of non-invasive 64-slice CT coronary angiography in patients with stable angina pectoris

    Energy Technology Data Exchange (ETDEWEB)

    Pugliese, Francesca; Krestin, Gabriel P. [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands); Mollet, Nico R.A.; deFeyter, Pim J. [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands); Erasmus Medical Center, Department of Cardiology, Rotterdam (Netherlands); Runza, Giuseppe [University of Palermo, Department of Radiology, Palermo (Italy); Azienda Ospedaliera di Parma, Department of Radiology, Parma (Italy); Mieghem, Carlos van; Meijboom, Willem B.; Baks, Timo [Erasmus Medical Center, Department of Cardiology, Rotterdam (Netherlands); Malagutti, Patrizia [Erasmus Medical Center, Department of Cardiology, Rotterdam (Netherlands); University of Ferrara, Department of Cardiology, Ferrara (Italy); Cademartiri, Filippo [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands); Azienda Ospedaliera di Parma, Department of Radiology, Parma (Italy)

    2006-03-15

    Multislice computed tomography (CT) is an emerging technique for the non-invasive detection of coronary stenoses. While the diagnostic accuracy of 4-slice scanners was limited, 16-slice CT imagers showed promising results due to increased temporal and spatial resolution. These technical advances prompted us to evaluate the diagnostic performance of 64-slice CT coronary angiography in the detection of significant stenoses (defined as {>=} 50% luminal diameter reduction) versus invasive quantitative coronary angiography (QCA). Thirty-five patients with stable angina pectoris underwent CT coronary angiography performed with a 64-slice scanner (gantry rotation time 330 ms, individual detector width 0.6 mm) prior to conventional coronary angiography. Patients with heart rates >70 beats/min received 100 mg metoprolol orally. One hundred millilitres of contrast agent with an iodine concentration of 400 mgl/ml were injected at a rate of 5 ml/s into the antecubital vein. The CT scan was triggered with the bolus tracking technique. The sensitivity, specificity and the positive and negative predictive values of 64-slice CT were 99%, 96%, 78% and 99%, respectively, on a per-segment basis. The values obtained on a per-patient basis were 100%, 90%, 96% and 100%, respectively. When referral to catheterisation is questionable, CT coronary angiography may identify subjects with normal angiograms and consistently decrease the number of unnecessary invasive procedures. (orig.)

  12. Diagnostic accuracy of non-invasive 64-slice CT coronary angiography in patients with stable angina pectoris

    International Nuclear Information System (INIS)

    Pugliese, Francesca; Krestin, Gabriel P.; Mollet, Nico R.A.; DeFeyter, Pim J.; Runza, Giuseppe; Mieghem, Carlos van; Meijboom, Willem B.; Baks, Timo; Malagutti, Patrizia; Cademartiri, Filippo

    2006-01-01

    Multislice computed tomography (CT) is an emerging technique for the non-invasive detection of coronary stenoses. While the diagnostic accuracy of 4-slice scanners was limited, 16-slice CT imagers showed promising results due to increased temporal and spatial resolution. These technical advances prompted us to evaluate the diagnostic performance of 64-slice CT coronary angiography in the detection of significant stenoses (defined as ≥ 50% luminal diameter reduction) versus invasive quantitative coronary angiography (QCA). Thirty-five patients with stable angina pectoris underwent CT coronary angiography performed with a 64-slice scanner (gantry rotation time 330 ms, individual detector width 0.6 mm) prior to conventional coronary angiography. Patients with heart rates >70 beats/min received 100 mg metoprolol orally. One hundred millilitres of contrast agent with an iodine concentration of 400 mgl/ml were injected at a rate of 5 ml/s into the antecubital vein. The CT scan was triggered with the bolus tracking technique. The sensitivity, specificity and the positive and negative predictive values of 64-slice CT were 99%, 96%, 78% and 99%, respectively, on a per-segment basis. The values obtained on a per-patient basis were 100%, 90%, 96% and 100%, respectively. When referral to catheterisation is questionable, CT coronary angiography may identify subjects with normal angiograms and consistently decrease the number of unnecessary invasive procedures. (orig.)

  13. Long-Term Clinical Impact of Coronary CT Angiography in Patients With Recent Acute-Onset Chest Pain

    DEFF Research Database (Denmark)

    Linde, Jesper J; Hove, Jens D; Sørgaard, Mathias

    2015-01-01

    . BACKGROUND: The prognostic implications of a coronary CTA-guided treatment strategy have not been compared in a randomized fashion to standard care in patients referred for acute-onset chest pain. METHODS: Patients with acute chest pain but normal electrocardiograms and troponin values were randomized...... to treatment guided by either coronary CTA or standard care (bicycle exercise electrocardiogram or myocardial perfusion imaging). In the coronary CTA-guided group, a functional test was included in cases of nondiagnostic coronary CTA images or coronary stenoses of borderline severity. The primary endpoint...... electrocardiograms and troponin values compared to standard care with a functional test. (Cardiac-CT in the Treatment of Acute Chest Pain [CATCH]; NCT01534000)....

  14. Endovascular Treatment of Central Vein Stenoses and/or Occlusions in Hemodialysis Patients

    International Nuclear Information System (INIS)

    Maskova, Jana; Komarkova, Jana; Kivanek, Jiri; Danes, Jan; Slavikova, Marcela

    2003-01-01

    Purpose: To report our experience and results with the endovascular treatment of central vein stenoses and occlusions in hemodialysis patients. Methods: Between October 1999 and August 2001 (22 months) we performed 22 interventional procedures in 14 hemodialysis patients (8 women, 6 men) ranging in age from 38 to 87 years (mean 76 years). The indication for intervention was stenosis (n = 10) or occlusion (n =4) of a central vein in the upper arm used for dialysis inpatients with arm swelling and/or shunt malfunction. All patients had a previous history of subclavian vein cannulation. There were six percutaneous transluminal angioplasties (PTAs) and eight primary stentplacements and eight repeat interventions. Seven were for restenoses and one for early occlusion, with two secondary stent placements and six PTA of in-stent stenoses. In two patients a second stent was implanted. The mean follow-up was 8.5 months (range 1-19 months). All stents were self-expandable with diameters ranging from 9 to 16 mm. Results: All but one of the procedures was technically successful (95%, n = 21). The patient with an unsuccessful procedure died 1 month after the procedure, but the death was not procedure-related. During follow-up three patients died with a patent shunt and central vein, none of them in connection with the procedure. No complication occurred during the interventional procedures. One patient was lost to follow-up. The primary patency rate at 12 months was 43%, with a primary assisted patency rate of 83% and a secondary patency rate of 100% (n 6). Conclusion: Central vein stenoses and occlusions are associated with previous subclavian vein cannulation. They are a serious problem in hemodialysis patients with a shunt on the same arm.Endovascular treatment is a suitable option for these patients

  15. Clinical observation of intraluminal stent angioplasty in the treatment of renal arterial stenoses

    International Nuclear Information System (INIS)

    Lu Yanwen; Zhang Jian; Huang Xianglong

    2002-01-01

    Objective: To evaluate the clinical application of intraluminal stent angioplasty (PTRAS) in the treatment of renal arterial stenoses. Methods: A retrospective study was done in 28 patients with renal arterial stenoses. Primary renal artery stenting was performed in 28 consecutive patients (36 renal arteries). Blood pressure, serum creating, the number of anti-hypertensive medications were recorded at 1, 6, 12 month post stent angioplasty respectively. Arterial angiography was also taken 1 year later to evaluate the incidence of restenosis. Results: Technical success rate was 100% achieving in all patients without serious complications. Primary successful patently rate reached 82% (renal artery 86%), secondary successful rate was 89% (renal artery 90%). Systolic and diastolic blood pressure were reduced significantly (P<0.01) at 1,6,12 month after stent angioplasty comparing with baseline and clinical improvement (cured + improved) of hypertension reached 100%, 92.9%, 89.3% respectively. There were no significant differences between serum creatine level and the number of anti-hypertensive medications before and after stent angioplasty. One year later, 14.3% of all patients showed improvement of renal function, 64.3% remained in stabilization and 21.4% fell into deterioration. Angiographic restenosis was found in 3 cases one year after stent angioplasty. Complications included 1 hematoma at puncture site and 3 transient azotaemia. Conclusions: PTRAS can be performed safely with high technical success and beneficial to the majority of patients with hypertension or renal insufficiency and therefore it should be the first choice in treating renal arterial stenoses

  16. Influence of some drugs, used in coronary artery disease on in vitro labelling red blood cells with technetium {sup 99m}Tc; Wplyw wybranych lekow, stosowanych w chorobie niedokrwiennej serca na wiazanie technetu {sup 99m}Tc przez erytrocyty in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Poniatowicz-Frasunek, E. [Katedra i Zaklad Medycyny Nuklearnej, Akademia Medyczna, Lublin (Poland)

    1997-12-31

    In some patients investigated by radionuclide ventriculography poor labeling efficiency of red blood cells with technetium {sup 99m}Tc is observed. Among possible mechanisms responsible for this phenomenon, the pharmacological treatment applied to the patients should be taken into consideration. The aim of the study was to define the effect of selected drugs used in CAD on technetium binding efficiency by erythrocytes in vitro. Blood samples were obtained from 40 normal individuals receiving no medication. The effect of the following drugs were examined: Aerosonit, Isoptin, Bemecor, Dopegyt, Enarenal, Binazin, Furosemid, Aspirin, Vitamin E and Propranolol. Only Enarenal and Vitamin E proved to have no effect on technetium binding efficiency. The most expressed reduction was observed in experiments with Aerosonit, Furosemid and Propranolol and the smallest changes were found in blood samples with Bemecor, Binazin and Aspirin. The results of the study suggest that pharmacological treatment may influence the quality of scintigraphic images obtained with radioisotope ventriculography. For that reason the medicines applied to the patients should be as much as possible reduced or withdrawn for at least several days before examination. (author) 23 refs, 4 figs, 2 tabs

  17. PHARMACOTHERAPY OF ACUTE STENOSING LARYNGOTRACHEITIS. WHAT DRUGS ARE DATA-BASED?

    Directory of Open Access Journals (Sweden)

    L. M. Ogorodova

    2012-01-01

    Full Text Available Acute stenosing laryngotracheitis is the most common cause of the upper respiratory tract obstruction in children at the age of 6 months to 6 years old. It is the rapidly occurring syndrome, consisting of barking cough, hoarseness, stridor. The disease can be associated with development of respiratory failure and asphyxia, so pediatricians and emergency care doctors must be well aware of rational pharmacotherapy of this condition. The review contains the descriptions of the drugs, which efficacy is confirmed by convincing evidence database. 

  18. Unsteady Blood Flow with Nanoparticles Through Stenosed Arteries in the Presence of Periodic Body Acceleration

    Science.gov (United States)

    Fatin Jamil, Dzuliana; Roslan, Rozaini; Abdulhameed, Mohammed; Che-Him, Norziha; Sufahani, Suliadi; Mohamad, Mahathir; Ghazali Kamardan, Muhamad

    2018-04-01

    The effects of nanoparticles such as Fe 3O4,TiO2, and Cu on blood flow inside a stenosed artery are studied. In this study, blood was modelled as non-Newtonian Bingham plastic fluid subjected to periodic body acceleration and slip velocity. The flow governing equations were solved analytically by using the perturbation method. By using the numerical approaches, the physiological parameters were analyzed, and the blood flow velocity distributions were generated graphically and discussed. From the flow results, the flow speed increases as slip velocity increases and decreases as the values of yield stress increases.

  19. Transluminal coronary angioplasty (TCA) techniques, indications and results

    International Nuclear Information System (INIS)

    Kober, G.; Lang, H.; Vallbracht, C.; Bussmann, W.D.; Hopf, R.; Kunkel, B.; Kaltenbach, M.

    1985-01-01

    Transluminal coronary angioplasty (TCA) was introduced in 1977 for dilatation of coronary stenoses. From October 1977 to December 1984 1087 procedures have been performed in Frankfurt. The mean success rate was 77% with an increase from 58% to 84% since 1977. Recurrences were seen within the first year in 15% of the patients, which could be treated successfully in a high percentage with a second TCA. Emergency bypass operations were necessary in 5.2%. Four patients (fatality rate 0.37%) died as the consequence of the intervention. Within few years TCA has become an established procedure for myocardial revascularisation, with a high success rate. Major progress has been possible in the last few years due to technical developments, which are still going on. They may lead to further improvement of the results and enlargement of the indication for TCA. (orig.) [de

  20. Ostial left main coronary stenosis in a frequent flyer.

    LENUS (Irish Health Repository)

    O'Sullivan, John F

    2009-05-15

    A 52 year old gentleman presented with chest pain, after a long distance flight from India; he had made long haul flights every 2 weeks over the last 5 years as part of his job. His ECG revealed T wave inversion in leads V1-3. Cardiac biomarkers including troponin were negative; we proceeded to exercise stress testing (EST). This revealed 2 mm ST depression at 2 min of the standard Bruce protocol, associated with chest pain. He was taken immediately to the coronary catheterization laboratory; engagement of the left main caused pressure damping with 6 French, then 5 French diagnostic Judkins left 4 catheters. An ostial left main stenosis was seen; the right and left coronary trees otherwise had no significant stenoses. He had normal LV function. He underwent inpatient CABG 7 days later.

  1. Clinical utility of coronary CT angiography with low-dose chest CT in the evaluation of patients with atypical chest pain: a preliminary report

    International Nuclear Information System (INIS)

    Lim, Soo Jin; Choo, Ki Seok; Kim, Chang Won

    2008-01-01

    To determine the clinical utility of coronary CT angiography (CCTA) with low-dose chest CT in the evaluation of patients with atypical chest pain. Ninety-six patients (mean age 60.2 years; age range, 41-68 years; 70 males) were referred for CCTA with low-dose chest CT (16-slice MDCT, Siemens) for an evaluation of atypical chest pain. When significant stenoses (lumen diameter reduction > 50%) were detected on CCTA, invasive coronary angiography (CA) was performed as the standard of reference. In all patients, medical chart review or telephone contact with patients was used to evaluate the contribution of CCTA with low-dose chest CT to the final clinical diagnosis, at least 6 months after performing CCTA. Among 96 patients, seven patients (7%) had significant stenoses as detected on CCTA, whereas two patients (2%) had significant stenoses and five patients had insignificant stenoses or no stenosis, as detected on conventional catheter angiography. In 18 (19%) of the 89 patients without significant stenosis detected on CCTA, this protocol provided additional information that suggested or confirmed an alternate clinical diagnosis. In patients with atypical chest pain, CCTA with low-dose chest CT could help to exclude ischemic heart disease and could provide important ancillary information for the final diagnosis

  2. Relationship of the duke jeopardy score combined with minimal lumen diameter as assessed by computed tomography angiography to the hemodynamic relevance of coronary artery stenosis.

    Science.gov (United States)

    Yu, Mengmeng; Zhao, Yonghong; Li, Wenbin; Lu, Zhigang; Wei, Meng; Zhou, Wenxiao; Zhang, Jiayin

    2018-03-02

    To study the diagnostic performance of the ratio between the Duke jeopardy score (DJS) and the minimal lumen diameter (MLD) (DJS/MLD CT ratio) as assessed by coronary computed tomographic angiography (CTA) for differentiating functionally significant from non-significant coronary artery stenoses, with reference to invasive fractional flow reserve (FFR). Patients who underwent both coronary CTA and FFR measurement during invasive coronary angiography (ICA) within 2 weeks were retrospectively included in the study. Invasive FFR measurement was performed in patients with intermediate to severe coronary stenoseis. DJS/MLD CT ratio and anatomical parameters were recorded. Lesions with FFR ≤0.80 were considered to be functionally significant. One hundred and sixty-one patients with 175 lesions were included into the analysis. Diameter stenosis in CT, area stenosis, plaque burden, lesion length (LL), ICA-based stenosis degree, DJS, LL/MLD 4 ratio, DJS/MLA ratio as well as DJS/MLD ratio were all significantly different between hemodynamically significant and non-significant lesions (pvalue for DJS/MLD CT ratio to be 1.96 (area under curve = 0.863, 95 % confidence interval = 0.803-0.910), yielding a high diagnostic accuracy (86.9%, 152/175). In coronary artery stenoses detected by coronary CTA, the DJS/MLD ratio is able to predict hemodynamic relevance. Copyright © 2018 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  3. Value of 3D-Volume Rendering in the Assessment of Coronary Arteries with Retrospectively Ecg-Gated Multislice Spiral CT

    International Nuclear Information System (INIS)

    Mahnken, A.H.; Wildberger, J.E.; Dedden, K.; Schmitz-Rode, T.; Guenther, R.W.; Sinha, A.M.; Hoffmann, R.; Stanzel, S.

    2003-01-01

    Purpose: To assess the diagnostic value and measurement precision of 3D volume rendering technique (3D-VRT) from retrospectively ECG-gated multislice spiral CT (MSCT) data sets for imaging of the coronary arteries. Material and Methods: In 35 patients, retrospectively ECG-gated MSCT of the heart using a four detector row MSCT scanner with a standardized examination protocol was performed as well as quantitative X-ray coronary angiography (QCA). The MSCT data was assessed on segmental basis using 3D-VRT exclusively. The coronary artery diameters were measured at the origin of each main coronary branch and 1 cm, 3 cm and 5 cm distally. The minimum, maximum and mean diameters were determined from MSCT angiography and compared to QCA. Results: A total of 353 of 525 (67.2%) coronary artery segments were assessable by MSCT angiography. The proximal segments were more often assessable when compared to the distal segments. Stenoses were detected with a sensitivity of 82.6% and a specificity of 92.8%. According to the Bland-Altman method the mean differences between QCA and MSCT ranged from 0.55 to 1.07 mm with limits of agreement from 2.2 mm to 2.7 mm. Conclusion: When compared to QCA, the ability of 3D-VRT to quantitatively assess coronary artery diameters and coronary artery stenoses is insufficient for clinical purposes

  4. Management of benign stenoses of the large airways in the university hospital in Prague, Czech Republic, in 1998-2003.

    Science.gov (United States)

    Marel, Miloslav; Pekarek, Zdenek; Spasova, Irena; Pafko, Pavel; Schutzner, Jan; Betka, Jan; Pospisil, Ronald

    2005-01-01

    Clinically significant benign stenoses of the large airways develop in about 1% of patients after intubation. The management of benign stenoses is not unified around the world, nor are there any accepted methods for their screening. The purpose of this study is to describe and compare results of interventional bronchoscopy and surgical therapy of benign stenoses as well as to propose an algorithm for the management of this airways disorder. Prospective study on 80 consecutive patients with benign stenoses of the large airways admitted to the Pulmonary Department of the University Hospital of Prague-Motol. Sixty-two patients developed stenoses after endotracheal intubation or tracheostomy, in 18 patients the stenosis was caused by other diseases or pathological situations. Thirty-eight patients were sent for surgical resection of the stenotic part of the airways. 2 surgically treated patients developed recurrence of the stenosis and had to be reoperated on. Narrowing of the trachea at the site of end-to-end anastomosis developed in 6 other patients and was cured by interventional bronchoscopy. The remaining 42 patients were treated by interventional bronchoscopy (Nd-YAG laser, electrocautery, stent) which was curative in 35 patients. Sixty-five patients were alive at the time of evaluation, 15 patients died. Five of them died between 3 and 14 (median 4) months after surgery from a disease other than airway stenosis. Ten nonresected patients also died, with 1 exception, due to a disease other than airway stenosis; the median survival was 9 months. We recommend to assess the patient for surgery after the initial diagnosis and therapeutic bronchoscopy with dilatation of the stenosis. If the patient is not a suitable candidate for resection, interventional bronchoscopy is an appropriate alternative for the management of benign stenoses of the large airways. Copyright (c) 2005 S. Karger AG, Basel.

  5. Argon Plasma Coagulation Combined with Covered Stent Placement for Management of Tracheobronchial Stenoses/occlusions as well as Esophagorespiratory Fistulas

    Directory of Open Access Journals (Sweden)

    Hongwu WANG

    2010-09-01

    Full Text Available Background and objective It is a complex problem and difficult treatment for tracheobronchial stenoses/occlusions involving in carina. The aim of this study is to investigate the feasibility and efficiency of argon plasma coagulation (APC and bifurcated covered Z-type stents (CZTS placement for the treatment of tracheobronchus stenoses and esophagorespiratory fistula (ERF. Methods Thirty-two cases with airway disorders were retrospectively reviewed for the treatment of APC and CZTS placement. Under the bronchoscopic guidance, APC was first given in patients with airway stenoses, then CZTS was placed under the fluoroscopic and flexible bronchoscopic guidance either with airway stenoses or ERF. Results APC was first given in 19 patients with airway stenoses. Airway structures were significantly improved after APC procedure (57.4%-72.1% before APC vs 12.8%-25.8% after APC. Thirty-two CZTS were technically successfully placed in 30 out of 32 cases involving in carinal bifurcation. After APC and stent placement, short breath index was significantly reduced and karnofsky physical score (KPS increased obviously. The endobronchial defects were successfully palliated with bifurcated CZTS placed under fluoroscopy and flexible bronchoscopy in 12 out of 13 patients with ERFs. There is no bleeding introprocedure. Mucous retention was very common in all types of the stents less than 2 weeks after stenting, which required debridement by bronchoscopy and could be prevented by normal saline solution nebulizations. Granuloma developed at the ends of stents after 1 month of stenting which all of them were treated successfully with APC and CO2 cryosurgery. Conclusion Utilization of APC and retrieval bifurcated CZTS placement is a simple and safe protocol for the management of airway complex stenoses involving the tracheal carina and ERF.

  6. Comparative study of Newtonian physiological blood flow through normal and stenosed carotid artery

    Science.gov (United States)

    Rahman, Mohammad Matiur; Hossain, Md. Anwar; Mamun, Khairuzzaman; Akhter, Most. Nasrin

    2017-06-01

    A numerical simulation is performed to investigate Newtonian physiological flows behavior on three dimensional idealized carotid artery (CA) and single stenosed (75% by area) carotid artery(SCA). The wall vessel is set as rigid during simulation. Bifurcated blood vessel are simulated by using three-dimensional flow analysis. Physiological and parabolic velocity profiles are set out to fix the conditions of inlet boundaries of artery. In other hand, physiological waveform is an important part of compilation and it is successfully done by utilization of Fourier series having sixteen harmonics. The investigation has a Reynolds number range of 94 to 1120. Low Reynolds number k — ω model has been used as governing equation. The investigation has been carried out to characterize the flow behavior of blood in two geometry, namely, (i) Normal carotid artery (CA) and (ii) Stenosed carotid artery (SCA). The Newtonian model has been used to study the physics of fluid. The findings of the two models are thoroughly compared in order to observe there behavioral sequence of flows. The numerical results were presented in terms of velocity, pressure, wall shear stress distributions and cross sectional velocities as well as the streamlines contour. Stenosis disturbs the normal pattern of blood flow through the artery as reduced area. At stenosis region velocity and peak Reynolds number rapidly increase and Reynolds number reach transitional and turbulent region. These flow fluctuation and turbulence have bad effect to the blood vessel which makes to accelerate the progress of stenosis.

  7. 2D Rotational Angiography for Fast and Standardized Evaluation of Peripheral and Visceral Artery Stenoses

    International Nuclear Information System (INIS)

    Katoh, Marcus; Opitz, Armin; Minko, Peter; Massmann, Alexander; Berlich, Joachim; Bücker, Arno

    2011-01-01

    Purpose: To investigate the value of rotational digital subtraction angiography (rDSA) for evaluation of peripheral and visceral artery stenoses compared to conventional digital subtraction angiography (cDSA). Methods: A phantom study was performed comparing the radiation dose of cDSA with two projections and rDSA by means of the 2D Dynavision technique (Siemens Medical Solutions, Forchheim, Germany). Subsequently, 33 consecutive patients (18 women, 15 men; mean ± SD age 67 ± 15 years) were examined by both techniques. In total, 63 vessel segments were analyzed by two observers with respect to stenoses, image contrast, and vessel sharpness. Results: Radiation dose was significantly lower with rDSA. cDSA and rDSA revealed 21 and 24 flow-relevant stenotic lesions and vessel occlusions (70–100%), respectively. The same stenosis grade was assessed in 45 segments. By means of rDSA, 10 lesions were judged to have a higher and 8 lesions a lower stenosis grade compared to cDSA. rDSA yielded additive information regarding the vessel anatomy and pathology in 29 segments. However, a tendency toward better image quality and sharper vessel visualization was seen with cDSA. Conclusion: rDSA allows for multiprojection assessment of peripheral and visceral arteries and provides additional clinically relevant information after a single bolus of contrast medium. At the same time, radiation dose can be significantly reduced compared to cDSA.

  8. Two-Fluid Mathematical Models for Blood Flow in Stenosed Arteries: A Comparative Study

    Directory of Open Access Journals (Sweden)

    Sankar DS

    2009-01-01

    Full Text Available The pulsatile flow of blood through stenosed arteries is analyzed by assuming the blood as a two-fluid model with the suspension of all the erythrocytes in the core region as a non-Newtonian fluid and the plasma in the peripheral layer as a Newtonian fluid. The non-Newtonian fluid in the core region of the artery is assumed as a (i Herschel-Bulkley fluid and (ii Casson fluid. Perturbation method is used to solve the resulting system of non-linear partial differential equations. Expressions for various flow quantities are obtained for the two-fluid Casson model. Expressions of the flow quantities obtained by Sankar and Lee (2006 for the two-fluid Herschel-Bulkley model are used to get the data for comparison. It is found that the plug flow velocity and velocity distribution of the two-fluid Casson model are considerably higher than those of the two-fluid Herschel-Bulkley model. It is also observed that the pressure drop, plug core radius, wall shear stress and the resistance to flow are significantly very low for the two-fluid Casson model than those of the two-fluid Herschel-Bulkley model. Hence, the two-fluid Casson model would be more useful than the two-fluid Herschel-Bulkley model to analyze the blood flow through stenosed arteries.

  9. In vivo measurement of hemodynamic information in stenosed rat blood vessels using X-ray PIV.

    Science.gov (United States)

    Park, Hanwook; Park, Jun Hong; Lee, Sang Joon

    2016-11-28

    Measurements of the hemodynamic information of blood flows, especially wall shear stress (WSS), in animal models with circulatory vascular diseases (CVDs) are important to understand the pathological mechanism of CVDs. In this study, X-ray particle image velocimetry (PIV) with high spatial resolution was applied to obtain velocity field information in stenosed blood vessels with high WSS. 3D clips fabricated with a 3D printer were applied to the abdominal aorta of a rat cadaver to induce artificial stenosis in the real blood vessel of an animal model. The velocity and WSS information of blood flows in the stenosed vessel were obtained and compared at various stenosis severities. In vivo measurement was also conducted by fastening a stenotic clip on a live rat model through surgical intervention to reduce the flow rate to match the limited temporal resolution of the present X-ray PIV system. Further improvement of the temporal resolution of the system might be able to provide in vivo measurements of hemodynamic information from animal disease models under physiological conditions. The present results would be helpful for understanding the relation between hemodynamic characteristics and the pathological mechanism in animal CVD models.

  10. The value of 3D-CT angiography and duplex sonography in comparison to arteriography in carotid artery stenoses

    International Nuclear Information System (INIS)

    Link, J.; Mueller-Huelsbeck, S.; Wesner, F.; Hoepfner, M.; Schwarzenberg, H.; Heller, M.

    1997-01-01

    To determine the value of 3D-CT angiography, duplex sonography in comparison to selective digital subtraction angiography for evaluation of carotid artery stenoses. Methods: 30 patients with 51 stenoses of carotid artery underwent 3D-CT angiography, duplex sonography and angiography. Quantification of stenosis was determined according to the NASCET study and categorized into mild (0-29%), moderate (30-69%), severe (70-99%) and occluded (100%). Results: The agreement of 3D-CT angiography with intraarterial digital subtraction angiography (DSA) was 62% (r=0.89; p [de

  11. Prevalence of asymptomatic coronary disease in fibrosing idiopathic interstitial pneumonias

    International Nuclear Information System (INIS)

    Cassagnes, Lucie; Gaillard, Vianney; Monge, Emmanuel; Faivre, Jean-Baptiste; Delhaye, Cédric; Molinari, Francesco; Petyt, Grégory; Hossein-Foucher, Claude; Wallaert, Benoit; Duhamel, Alain; Remy, Jacques; Remy-Jardin, Martine

    2015-01-01

    Background: Because of growing body of interest on the association between fibrosing idiopathic interstitial pneumonias (f-IIP) and ischaemic heart disease, we initiated this prospective study to evaluate the prevalence of asymptomatic coronary artery disease (CAD) in patients with f-IIP. Methods: Forty-two patients with f-IIP underwent noninvasive screening for CAD that included (a) a chest CT examination enabling calculation of the coronary artery calcium (CAC) score, then depiction of coronary artery stenosis; and (b) stress myocardial perfusion scintigraphy (MPS). Patients with significant coronary abnormalities, defined by a CAC score >400 or coronary artery stenosis >50% at CT and/or perfusion defect >5% at MPS, were referred to the cardiologist. Coronary angiography was indicated in presence of a perfusion defect >10% at MPS or significant left main or proximal left anterior descending stenosis whatever MPS findings. Results: Combining CT and MPS, significant abnormalities were detected in 32/42 patients (76%). The cardiologist: (a) did not consider further investigation in 21 patients (CT abnormalities but no ischaemia at MPS: 12/21; false-positive findings at MPS: 3/21; poor respiratory condition: 6/21); (b) proceeded to coronary angiography in 11 patients which confirmed significant stenoses in 5 patients (5/42; 12%). In the worst-case-scenario (i.e., inclusion of 6 patients with significant coronary artery abnormalities who were not investigated due to poor respiratory condition), the prevalence of CAD reached 26% (11/42). Conclusion: In the studied population of patients with f-IIP, asymptomatic CAD ranged between 12% and 26%

  12. Prevalence of asymptomatic coronary disease in fibrosing idiopathic interstitial pneumonias

    Energy Technology Data Exchange (ETDEWEB)

    Cassagnes, Lucie; Gaillard, Vianney [Department of Thoracic Imaging (EA 2694), Hospital Calmette, CHRU and Univ Lille 2 Nord de France, F-59000 Lille (France); Monge, Emmanuel [Department of Pulmonology, Center of Competence for Rare Pulmonary Diseases, Hospital Calmette, CHRU and Univ Lille 2 Nord de France, F-59000 Lille (France); Faivre, Jean-Baptiste [Department of Thoracic Imaging (EA 2694), Hospital Calmette, CHRU and Univ Lille 2 Nord de France, F-59000 Lille (France); Delhaye, Cédric [Department of Cardiology, Cardiology Hospital, CHRU and Univ Lille 2 Nord de France, F-59000 Lille (France); Molinari, Francesco [Department of Thoracic Imaging (EA 2694), Hospital Calmette, CHRU and Univ Lille 2 Nord de France, F-59000 Lille (France); Petyt, Grégory; Hossein-Foucher, Claude [Department of Nuclear Medicine, Hospital Salengro, CHRU and Univ Lille 2 Nord de France, F-59000 Lille (France); Wallaert, Benoit [Department of Pulmonology, Center of Competence for Rare Pulmonary Diseases, Hospital Calmette, CHRU and Univ Lille 2 Nord de France, F-59000 Lille (France); Duhamel, Alain [Department of Medical Statistics (EA 2694), Univ Lille Nord de France, F-59000 Lille (France); Remy, Jacques [Department of Thoracic Imaging (EA 2694), Hospital Calmette, CHRU and Univ Lille 2 Nord de France, F-59000 Lille (France); Remy-Jardin, Martine, E-mail: martine.remy@chru-lille.fr [Department of Thoracic Imaging (EA 2694), Hospital Calmette, CHRU and Univ Lille 2 Nord de France, F-59000 Lille (France)

    2015-01-15

    Background: Because of growing body of interest on the association between fibrosing idiopathic interstitial pneumonias (f-IIP) and ischaemic heart disease, we initiated this prospective study to evaluate the prevalence of asymptomatic coronary artery disease (CAD) in patients with f-IIP. Methods: Forty-two patients with f-IIP underwent noninvasive screening for CAD that included (a) a chest CT examination enabling calculation of the coronary artery calcium (CAC) score, then depiction of coronary artery stenosis; and (b) stress myocardial perfusion scintigraphy (MPS). Patients with significant coronary abnormalities, defined by a CAC score >400 or coronary artery stenosis >50% at CT and/or perfusion defect >5% at MPS, were referred to the cardiologist. Coronary angiography was indicated in presence of a perfusion defect >10% at MPS or significant left main or proximal left anterior descending stenosis whatever MPS findings. Results: Combining CT and MPS, significant abnormalities were detected in 32/42 patients (76%). The cardiologist: (a) did not consider further investigation in 21 patients (CT abnormalities but no ischaemia at MPS: 12/21; false-positive findings at MPS: 3/21; poor respiratory condition: 6/21); (b) proceeded to coronary angiography in 11 patients which confirmed significant stenoses in 5 patients (5/42; 12%). In the worst-case-scenario (i.e., inclusion of 6 patients with significant coronary artery abnormalities who were not investigated due to poor respiratory condition), the prevalence of CAD reached 26% (11/42). Conclusion: In the studied population of patients with f-IIP, asymptomatic CAD ranged between 12% and 26%.

  13. Coronary magnetic resonance imaging: visualization of the vessel lumen and the vessel wall and molecular imaging of arteriothrombosis

    International Nuclear Information System (INIS)

    Spuentrup, Elmar; Botnar, Rene M.

    2006-01-01

    Coronary magnetic resonance (MR) imaging has dramatically emerged over the last decade. Technical improvements have enabled reliable visualization of the proximal and midportion of the coronary artery tree for exclusion of significant coronary artery disease. However, current technical developments focus also on direct visualization of the diseased coronary vessel wall and imaging of coronary plaque because plaques without stenoses are typically more vulnerable with higher risk of plaque rupture. Plaque rupture with subsequent thrombosis and vessel occlusion is the main cause of myocardial infarction. Very recently, the first success of molecular imaging in the coronary arteries has been demonstrated using a fibrin-specific contrast agent for selective visualization of coronary thrombosis. This demonstrates in general the high potential of molecular MR imaging in the field of coronary artery disease. In this review, we will address recent technical advances in coronary MR imaging, including visualization of the lumen and the vessel wall and molecular imaging of coronary arteriothrombosis. First results of these new approaches will be discussed. (orig.)

  14. N-13 ammonia positron tomography at rest and during exercise for evaluation of coronary artery disease

    International Nuclear Information System (INIS)

    Tamaki, N.; Yonekura, Y.; Senda, M.

    1985-01-01

    To assess the value of positron computed tomography (PCT) for evaluation of coronary artery disease (CAD), N-13 ammonia myocardial PCT was performed at rest and during exercise in 23 cases. PCT imaging was taken with a wholebody multislice PCT device 3 minutes after intravenous injection of 20-20 mCi of N-13 ammonia. The tracer distribution was homogenous in the left ventricular myocardium at rest and during exercise in all 4 normal cases. Among 19 cases with CAD, regional hypoperfusion was observed in 24 cases (74%) at rest and 18 cases (95%) during exercise. Furthermore, 12 cases had regional perfusion abnormalities in stress images not present at rest. Segmental analysis of myocardial perfusion identified 30 of the 34 stenosed vessels (88%) with only one false positive finding (specificity: 97%). In 11 patients who underwent both thallium-201 and N-13 ammonia imaging, PCT detected stenosed vessels more (87%) than the thallium-201 imaging (63%: p<0.05), especially in those with multivessel disease (87% vs 63%: p 0.05). For quantitative analysis of myocardial perfusion by PCT, % change in tracer concentration from resting to stress state was calculated. It was mildly increased (14.4+- 5.8%: p<0.001) in normal segments, whereas in CAD, it was significantly decreased (-18.0+- 18.3%: p<0.02) in segments with stenosed vessels. The authors conclude that N-13 ammonia PCT during exercise is a sensitive and effective method for detecting CAD and identifying stenosed vessels, and it permits quantitative assessment of coronary reserve function

  15. Facilitating coronary artery evaluation in MDCT using a 3D automatic vessel segmentation tool

    International Nuclear Information System (INIS)

    Fawad Khan, M.; Gurung, Jessen; Maataoui, Adel; Brehmer, Boris; Herzog, Christopher; Vogl, Thomas J.; Wesarg, Stefan; Dogan, Selami; Ackermann, Hanns; Assmus, Birgit

    2006-01-01

    The purpose of this study was to investigate a 3D coronary artery segmentation algorithm using 16-row MDCT data sets. Fifty patients underwent cardiac CT (Sensation 16, Siemens) and coronary angiography. Automatic and manual detection of coronary artery stenosis was performed. A 3D coronary artery segmentation algorithm (Fraunhofer Institute for Computer Graphics, Darmstadt) was used for automatic evaluation. All significant stenoses (>50%) in vessels >1.5 mm in diameter were protocoled. Each detection tool was used by one reader who was blinded to the results of the other detection method and the results of coronary angiography. Sensitivity and specificity were determined for automatic and manual detection as well as was the time for both CT-based evaluation methods. The overall sensitivity and specificity of the automatic and manual approach were 93.1 vs. 95.83% and 86.1 vs. 81.9%. The time required for automatic evaluation was significantly shorter than with the manual approach, i.e., 246.04±43.17 s for the automatic approach and 526.88±45.71 s for the manual approach (P<0.0001). In 94% of the coronary artery branches, automatic detection required less time than the manual approach. Automatic coronary vessel evaluation is feasible. It reduces the time required for cardiac CT evaluation with similar sensitivity and specificity as well as facilitates the evaluation of MDCT coronary angiography in a standardized fashion. (orig.)

  16. CURRENT APPROACHES TO EVALUATION OF THE MULTIVESSEL CORONARY ATHEROSCLEROSIS IN PATIENTS WITH CHRONIC ISCHEMIC HEART DISEASE

    Directory of Open Access Journals (Sweden)

    D. N. Perutsky

    2011-01-01

    Full Text Available Aim. To determine the validity of stress echocardiography by fractional reserve blood flow (FFR as the reference method in detection of coronary arteries requiring revascularization, as well as to optimize the determination of the functional significance of coronary artery lesions in patients with multivessel coronary atherosclerosis. Material and methods. Patients (n=36 with stable angina class 2-3 with multivessel coronary atherosclerosis were included into the study. Stress echocardiography with dobutamine or exercise test (treadmill was performed in all patients. Selective coronary angiography with subsequent evaluation of FFR was carried out in patients with a positive result of stress echocardiography. Totally 108 arteries (87 with stenosing atherosclerosis were assessed.  Results. According to coronary angiography bi-vessel and three-vessel damages were revealed in 21 (58% and 15 (42% patients, respectively. Method of stress echocardiography as compared with FFR shown sensitivity — 58%, specificity — 95%, positive predictive value — 87%, positive predictive value of a negative result — 17%. Method of coronary angiography (as a method to detect significant stenosis by visual assessment of coronary artery as compared with FFR demonstrated sensitivity 100%, specificity — 30%, positive predictive value — 42%. Conclusion. Stress echocardiography for noninvasive patient examination improves the accuracy of determination for the need and extent of revascularization.

  17. Usefulness of preoperative coronary angiography and brain computed tomography in cases of coronary artery disease and cerebrovascular disease undergoing revascularization for arteriosclerosis obliterans

    International Nuclear Information System (INIS)

    Sakurada, Tall; Shibata, Yoshiki

    2003-01-01

    Coronary angiography and brain computed tomography were preoperatively performed to evaluate the clinical condition of coronary artery disease and cerebrovascular disease in 101 patients (mean age, 68.4 years) with revascularization for arteriosclerosis obliterans. Eighty patients had hypertension, 12 had diabetes, and 26 had hyperlipidemia. Seventy-one patients (70.3%) had coronary stenosis. Significant stenoses in major coronary artery branches were confirmed in 35 patients, including 13 patients with old myocardial infarction. Coronary artery bypass grafting and percutaneous coronary angioplasty were performed in 2 and 7 patients with critical stenosis, respectively. Of 57 patients, who underwent brain computed tomography, abnormalities were found in 52 patients (91.2%), including cortical infarction in 9, lacunar infarction in 35, and leukoaraiosis in 27 patients. During the follow-up period 13 patients died (including 3 cases of myocardial infarction and 3 cases of stroke). Actuarial survival rate at 5 years was 80.4%. The influence of ischemic heart disease and cerebrovascular disease on early and late mortality after surgical reconstruction for peripheral occlusive vascular disease is significant. Using visual diagnostic techniques, such as coronary angiography and brain computed tomography, long term survivor should be closely observed for multiple arteriosclerotic vascular diseases. (author)

  18. Usefulness of preoperative coronary angiography and brain computed tomography in cases of coronary artery disease and cerebrovascular disease undergoing revascularization for arteriosclerosis obliterans

    Energy Technology Data Exchange (ETDEWEB)

    Sakurada, Tall; Shibata, Yoshiki [Southern Tohoku Fukushima Hospital (Japan)

    2003-05-01

    Coronary angiography and brain computed tomography were preoperatively performed to evaluate the clinical condition of coronary artery disease and cerebrovascular disease in 101 patients (mean age, 68.4 years) with revascularization for arteriosclerosis obliterans. Eighty patients had hypertension, 12 had diabetes, and 26 had hyperlipidemia. Seventy-one patients (70.3%) had coronary stenosis. Significant stenoses in major coronary artery branches were confirmed in 35 patients, including 13 patients with old myocardial infarction. Coronary artery bypass grafting and percutaneous coronary angioplasty were performed in 2 and 7 patients with critical stenosis, respectively. Of 57 patients, who underwent brain computed tomography, abnormalities were found in 52 patients (91.2%), including cortical infarction in 9, lacunar infarction in 35, and leukoaraiosis in 27 patients. During the follow-up period 13 patients died (including 3 cases of myocardial infarction and 3 cases of stroke). Actuarial survival rate at 5 years was 80.4%. The influence of ischemic heart disease and cerebrovascular disease on early and late mortality after surgical reconstruction for peripheral occlusive vascular disease is significant. Using visual diagnostic techniques, such as coronary angiography and brain computed tomography, long term survivor should be closely observed for multiple arteriosclerotic vascular diseases. (author)

  19. In-vitro diagnosis

    DEFF Research Database (Denmark)

    Poulsen, Lars K.

    2001-01-01

    This review on in-vitro diagnostic methods focuses on the use of methods to perform risk assessment on foods. Based on the International Life Science Institute (ILSI) risk decision tree, the methods are discussed and three scenarios are suggested: (i) testing for a well-known allergen; (ii) testing...

  20. Cotton regeneration in vitro

    Science.gov (United States)

    H. F. Sakhanokho and K. Rajasekaran Over the years, plant breeders have improved cotton via conventional breeding methods, but these methods are time-consuming. To complement classical breeding and, at times, reduce the time necessary for new cultivar development, breeders have turned to in vitro ...

  1. Detection of benign hilar bile duct stenoses - A retrospective analysis in 250 patients with suspicion of Klatskin tumour.

    Science.gov (United States)

    Scheuermann, Uwe; Widyaningsih, Rizky; Hoppe-Lotichius, Maria; Heise, Michael; Otto, Gerd

    2016-06-01

    The aim of this study was to identify clinical, laboratory and radiological parameters to distinguish benign from malignant stenoses of the proximal bile duct. Between 1997 and 2011, 250 patients were referred to our clinic with hilar bile duct stenoses suspicious for Klatskin tumour. Medical histories, clinical data, pre-interventional laboratory tests, imaging findings, as well as therapeutic approach and patient outcome were compared to final histological results. All data were retrieved from our prospectively maintained database and analysed retrospectively. We found benign bile duct lesions in 34 patients (13.6%). Among the entire study population, uni- and multivariate analyses of 18 clinicopathological parameters revealed that patient age, serum alkaline phosphatase, tumour marker CA19-9 and presence of tumour mass in computed tomography were independent predictors for malignant biliary stenoses (p hilar biliary stenoses of 74.6%, 80.0% and 83.5%, respectively. Surgical resection could be avoided by preoperative work-up and surgical exploration in 10 out of 34 patients with benign lesions. Rates of major liver resections performed were 66.7% in the benign lesion group and 90.7% in the Klatskin tumour group. Despite improvements of preoperative diagnostics, it remains difficult to differentiate between benign and malignant hilar bile duct stenosis. Even explorative laparotomy was not able to safely exclude Klatskin tumour in all cases and therefore major liver resection was inevitable.

  2. The predictive value of angiographic results for the outcome of percutaneous transluminal angioplasty in stenosed femoral bypass grafts

    International Nuclear Information System (INIS)

    Spijkerboer, Anje M.; Beek, Frederik J. A.; Graaf, Yolanda van der; Eikelboom, Bert C.; Mali, Willem P. T. M.

    1997-01-01

    Purpose. To assess the predictive value of immediate angiographic results after percutaneous transluminal angioplasty (PTA) for stenoses in femoral bypass grafts using duplex ultrasound (DUS) criteria. Methods. A 1-year follow-up with DUS was performed in 38 patients with 50 stenoses in 41 grafts, treated with PTA for a graft stenosis. The indication for PTA according to DUS criteria was a severe stenosis in 43 lesions, and a moderate stenosis in 7 lesions. In the moderate stenosis group 3 patients showed claudication and 1 patient had a nonhealing ulcer. For the purposes of statistical evaluation, primary patency was considered present if the graft was not occluded. The graft was considered to have failed when it was found to be occluded on DUS, or when secondary interventions (surgery, repeat PTA) were performed. Results. After 1 year the cumulative primary patency rate was 44$ [95% confidence interval (CI) 27.8-59.8]. Stenoses with initially good angiographic results after PTA (<30% residual stenosis) were 2.9 times more likely to be patent at 1 year than stenoses with initially poor or moderate angiographic results (hazard ratio 2.9, 95% CI 1.3-6.4,p=0.007). Conclusion. A poor or moderate angiographic result immediately following PTA was prognostic for poor long-term results and may indicate a requirement for earlier surgical intervention

  3. Predictors of stenosing tenosynovitis in the hand and hand-related activity limitations in patients with rheumatoid arthritis.

    NARCIS (Netherlands)

    Ursum, J.; Horsten, N.C.; Hoeksma, A.F.; Dijkmans, B.A.; Knol, D.L.; Schaardenburg, D. van; Dekker, J.; Roorda, L.D.

    2011-01-01

    Objectives: To identify early predictors of stenosing tenosynovitis in the hand and hand-related activity limitations in patients with rheumatoid arthritis (RA). Design: A longitudinal study of an inception cohort. Setting: A large outpatient clinic. Participants: Consecutive patients who attended

  4. Contrast enhanced MRA: do contrast agents with a higher T1 relaxitivity improve the visualization of carotid artery stenoses?

    International Nuclear Information System (INIS)

    Friese, S.; Krapf, H.; Skalej, M.; Kueker, W.; Fetter, M.; Vonthein, R.

    2001-01-01

    CE-MRA is a powerful tool for the non-invasive evaluation of carotid artery occlusive disease. However, due to certain drawbacks, it has not completely replaced DSA. The purpose of this study was to evaluate if Gd-BOPTA, a contrast agent with high T 1 relaxivity, can increase the diagnostic accuracy of CE-MRA. Material and Methods: The CE-MRA examinations of 54 consecutive patients were evaluated by two experienced radiologists, independently. The examinations of 27 patients were contrasted either with 20 ml Gd-BOPTA or with 20 ml Gd-DTPA. The reviewers were blinded to the contrast agent chosen and to the ultrasound results. They rated the overall image quality and the degree of the ICA stenoses. Results: For the estimation of the degree of the ICA stenoses there was a high interrater validity. In comparison to the ultrasound findings, 6 of 50 high-degree stenoses were underestimated as moderate stenoses. In one of seven sonographically occluded vessels, MRA revealed residual patency in the vessel lumen. It was not possible to identify the contrast agent that was taken for a study. Subjective estimation of the image quality (arterial contrast of the ICA, contrast of the other vessels, and general impression) did not significantly change with the contrast agent employed. Conclusion: The diagnostic accuracy of CE-MRA for the evaluation of internal carotid artery stenoses is not improved by Gd-BOPTA if identical volumina of contrast media are applied. The potential of this contrast agent can be the reduction of the amount of contrast without loss of diagnostic information. Further studies are necessary. (orig.) [de

  5. Diagnostic accuracy of coronary angiography with multislice computed tomography applied to 'the Real World'

    International Nuclear Information System (INIS)

    Rodriguez Granillo, Gaston A.; Rosales, Miguel A.; Llaurado, Claudio; Fernandez Pereira, Carlos; Garcia Carcia, Hector M.

    2006-01-01

    Objective: To assess the diagnostic accuracy of Coronary Angiography with Multislice Computed Tomography (MSCT) for the detection of significant coronary artery stenoses. Material and methods: Patients studied had an indication for diagnostic coronary angiography and no history of contrast allergies, renal failure or arrhythmias. A multislice tomography equipment (Brilliance 40, Philips, The Netherlands) with ECG gating was used for image acquisition. A total of 90-125 mI of iodinated contrast was administered by IV route. Obesity, diabetes, diffusely calcified segments with a diameter < 2.0 mm, and segments treated with stents were not considered exclusion criteria. Lesions were defined as significant when the decrease in Iumen was ≥ 50% by MSCT and quantitative coronary angiography (QCA). Results: A total of 38 patients were scanned before the intervention. Of them, one (3%) was excluded because of inadequate image quality. The remaining 37 patients (444 segments), with an adequate quality image, were included in the study (81% men, mean age 62.43 ± 12.5 years, 13.5% diabetics). Mean scan time was 15.12 ± 2.6 seconds, and 444 segments were assessed with both techniques. The number of lesions deemed significant by QCA and MSCT were 88 (17%) and 93 (18%), respectively. Sensitivity, specificity, positive and negative predictive values of MSCT to detect significant stenoses were 82%, 93%, 72% and 96%, respectively. Conclusion: In non-selected patients, coronary angiography by multislice computed tomography exhibits a high negative predictive value for the detection of obstructive coronary disease. (author)

  6. Acute Reversible Heart Failure Caused by Coronary Vasoconstriction due to Continuous 5-Fluorouracil Combination Chemotherapy

    Directory of Open Access Journals (Sweden)

    Cornelia Dechant

    2012-06-01

    Full Text Available We present the case of a 51-year-old male patient who received adjuvant chemotherapy consisting of oxaliplatin, bolus and continuous 5-fluorouracil (5-FU and leucovorin after anterior resection because of locally advanced rectal cancer. Preoperative chemotherapy with capecitabine (an oral 5-FU prodrug had been well tolerated. Two days after initiation of the first course of chemotherapy, the patient reported typical chest pain. The ECG showed ST elevations and prominent T waves in almost all leads. Due to suspicion of a high-risk acute coronary syndrome, an urgent cardiac catheterization was performed. It showed a generally reduced coronary flow with multiple significant stenoses (including the ostia of the left and right coronary artery, as well as a highly reduced left ventricular function with diffuse hypokinesia. Due to the meanwhile completely stable situation of the patient after medical acute coronary syndrome treatment, no ad hoc intervention was performed to allow further discussion of the optimal management. Thereafter, the patient remained clinically asymptomatic, without any rise in cardiac necrosis parameters; only NT-pro-BNP was significantly elevated. A control cardiac catheterization 2 days later revealed a restored normal coronary artery flow with only coronary calcifications without significant stenoses, as well as a normal left ventricular ejection fraction. Cardiovascular symptoms occurred on the second day of continuous 5-FU treatment. As cardiotoxic effects seem to appear more frequently under continuous application of 5-FU, compared to the earlier established 5-FU bolus regimens, treating medical oncologists should pay special attention to occurring cardiac symptoms and immediately interrupt 5-FU chemotherapy and start a cardiologic work-up.

  7. Myocardial scintigraphy with 201thallium for the diagnosis of coronary heart disease and heart muscle disease

    International Nuclear Information System (INIS)

    Keller, E.

    1986-01-01

    This work gives an overview of the presently used methods of diagnostic and therapy of coronary heart disease. With the use of 105 patients the viability of scintigraphical and radiological studies were compared to each other. The thallium scintigraphy thereby achieves excellent results with a sensitivity of 95% of coronary heart disease (with a pre-determined exclusion of myocardial diseases). In three cases small vessel disease was detected which could not be detected by a coronary angiogram. The correct localization of coronary stenosis with thallium scintigraphy was attained in the area of LAD at 77% and in the avea of RCA at 74% fairly reliable, whereas the determination of circumflex artery (sensitivity 29%) was rather poor. Also, the excact determination of the extent of coronary sclerosis shows that with multiple vessel diseases the sensitivity clearly decreases (1-vessel 78%, 2-vessel 38%, 3-vessel 13%), whereby the various coronary stenoses probably appear differently in scintigraphs. A better study method for the exact determination of the extent of myocardial ischemia is offered by the single photon emission computer tomography (SPECT) with the use of a rotating gamma camera. In view of the differential diagnostic for coronary diseases myocardial scintigraphy still plays a major role in myocardial diseases. In my own research pathological storage patterns could be shown in 14 such cases. (orig./MG) [de

  8. Fractional flow reserve-guided percutaneous coronary intervention: where to after FAME 2?

    Directory of Open Access Journals (Sweden)

    van de Hoef TP

    2015-12-01

    Full Text Available Tim P van de Hoef,1 Martijn Meuwissen,2 Jan J Piek1 1AMC Heartcentre, Academic Medical Center, University of Amsterdam, Amsterdam, 2Amphia Hospital, Breda, the Netherlands Abstract: Fractional flow reserve (FFR is a well-validated clinical coronary physiological parameter derived from the measurement of coronary pressures and has drastically changed revascularization decision-making in clinical practice. Nonetheless, it is important to realize that FFR is a coronary pressure-derived estimate of coronary blood flow impairment. It is thereby not the same as direct measures of coronary flow impairment that determine the occurrence of signs and symptoms of myocardial ischemia. This consideration is important, since the FAME 2 study documented a limited discriminatory power of FFR to identify stenoses that require revascularization to prevent adverse events. The physiological difference between FFR and direct measures of coronary flow impairment may well explain the findings in FAME 2. This review aims to address the physiological background of FFR, its ambiguities, and its consequences for the application of FFR in clinical practice, as well as to reinterpret the diagnostic and prognostic characteristics of FFR in the light of the recent FAME 2 trial outcomes. Keywords: fractional flow reserve, coronary flow, stable ischemic heart disease

  9. Role of coronary CT angiography in asymptomatic patients with type 2 diabetes mellitus

    International Nuclear Information System (INIS)

    Kamimura, Munehiro; Moroi, Masao; Hiroe, Michiaki; Isobe, Mitsuaki

    2012-01-01

    Diabetic patients with coronary artery disease are often asymptomatic, making appropriate care of such patients difficult. The purpose of this study was to investigate the prevalence of coronary lesions in asymptomatic diabetic patients. Coronary computed tomography (CT) angiography was performed in 120 consecutive diabetic patients (90 of whom were men, mean age 65, mean HbA1c 7.2%). Images from patients whose coronary artery calcium scores (CAC scores) were less than 400 were subjected to stenosis and plaque analysis. Significant stenosis was defined as coronary artery stenosis >70%. High-risk plaque was defined as plaque having both a CT density <30 Hounsfield Units (HU) and showing positive remodeling. Significant stenoses were identified in 30.5% of the patients. High-risk plaques were identified in 17.1% of the patients. Less than half of the high-risk plaques were obstructive plaques. There was a statistically significant association between significant stenosis and high-risk plaque by chi-square test (P=0.022). We found significant stenosis even in patients whose CAC score =0 at a rate of 5.0%. Using univariate logistic-regression analysis, we found that coronary risk factors associated with significant stenosis and high-risk plaque were dyslipidemia (P=0.033) and current smoking (P=0.030), respectively. We report for the first time, the prevalence of high-risk plaques in the arteries of patients with asymptomatic diabetes, as assessed by coronary CT angiography. (author)

  10. In vitro eugenics.

    Science.gov (United States)

    Sparrow, Robert

    2014-11-01

    A series of recent scientific results suggest that, in the not-too-distant future, it will be possible to create viable human gametes from human stem cells. This paper discusses the potential of this technology to make possible what I call 'in vitro eugenics': the deliberate breeding of human beings in vitro by fusing sperm and egg derived from different stem-cell lines to create an embryo and then deriving new gametes from stem cells derived from that embryo. Repeated iterations of this process would allow scientists to proceed through multiple human generations in the laboratory. In vitro eugenics might be used to study the heredity of genetic disorders and to produce cell lines of a desired character for medical applications. More controversially, it might also function as a powerful technology of 'human enhancement' by allowing researchers to use all the techniques of selective breeding to produce individuals with a desired genotype. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  11. Carotid disease in diabetic patients undergoing coronary artery bypass grafting

    International Nuclear Information System (INIS)

    Shahid, M.; Abid, A.R.; Dar, M.A.; Noeman, A.; Amin, S.; Azhar, M.

    2012-01-01

    Objective: To compare the severity of carotid artery disease in diabetic and non-diabetic patients undergoing coronary artery bypass grafting. Methods: From January to June 2008, 379 patients undergoing elective coronary artery bypass surgery were preoperatively evaluated for the presence of carotid stenoses by duplex scanning. Patients were divided into two groups, Group I, 156 (41.2%) diabetic patients and Group II, 223 (58.8%) non-diabetic patients. Results: There were 314 (82.8%) males and 65 (17.2%) females with a mean age of 57.2+-9.1 years. In diabetic group there were 125 (80.1%) males and 31 (19.9%) females with a mean age of 56.3+-8.9 years. Left main stem stenosis was present in 59 (37.8%) diabetics and 45 (20.2%) non-diabetics (p 70% stenosis was present in 20 (5.3%) with 13 (8.3%) diabetics and 7 (3.1%) non-diabetics (p<0.025). Stenosis of 50-70% was observed in 30 (7.9%) of which 17 (10.9%) were diabetics and 13 (5.8%) were non-diabetics. Conclusion: Presence of diabetes mellitus is associated with diffuse coronary artery disease and significant carotid artery disease in patients undergoing coronary artery bypass grafting. (author)

  12. Measurement of the blood flow rate and velocity in coronary artery stenosis using intracoronary frequency domain optical coherence tomography: Validation against fractional flow reserve.

    Science.gov (United States)

    Zafar, Haroon; Sharif, Faisal; Leahy, Martin J

    2014-12-01

    The main objective of this study was to assess the blood flow rate and velocity in coronary artery stenosis using intracoronary frequency domain optical coherence tomography (FD-OCT). A correlation between fractional flow reserve (FFR) and FD-OCT derived blood flow velocity is also included in this study. A total of 20 coronary stenoses in 15 patients were assessed consecutively by quantitative coronary angiography (QCA), FFR and FD-OCT. A percutaneous coronary intervention (PCI) optimization system was used in this study which combines wireless FFR measurement and FD-OCT imaging in one platform. Stenoses were labelled severe if FFR ≤ 0.8. Blood flow rate and velocity in each stenosis segment were derived from the volumetric analysis of the FD-OCT pull back images. The FFR value was ≤ 0.80 in 5 stenoses (25%). The mean blood flow rate in severe coronary stenosis ( n  = 5) was 2.54 ± 0.55 ml/s as compared to 4.81 ± 1.95 ml/s in stenosis with FFR > 0.8 ( n  = 15). A good and significant correlation between FFR and FD-OCT blood flow velocity in coronary artery stenosis ( r  = 0.74, p  < 0.001) was found. The assessment of stenosis severity using FD-OCT derived blood flow rate and velocity has the ability to overcome many limitations of QCA and intravascular ultrasound (IVUS).

  13. Accuracy of automated software-guided detection of significant coronary artery stenosis by CT angiography: comparison with invasive catheterisation

    International Nuclear Information System (INIS)

    Anders, Katharina; Uder, Michael; Achenbach, Stephan; Petit, Isabel; Daniel, Werner G.; Pflederer, Tobias

    2013-01-01

    True automated detection of coronary artery stenoses might be useful whenever expert evaluation is not available, or as a ''second reader'' to enhance diagnostic confidence. We evaluated the accuracy of a PC-based stenosis detection tool alone and combined with expert interpretation. One hundred coronary CT angiography datasets were evaluated with the automated software alone, by manual interpretation (axial images, multiplanar reformations and maximum intensity projections in free double-oblique planes), and by expert interpretation aware of the automated findings. Stenoses ≥ 50 % were noted per-vessel and per-patient, and compared with invasive angiography. Automated post-processing was successful in 90 % of patients (88 % of vessels). When excluding uninterpretable datasets, per-patient sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were 89 %, 79 %, 74 % and 92 % (per-vessel: 82 %, 85 %, 48 % and 96 %). All 100 datasets were evaluable by expert interpretation. Per-patient sensitivity, specificity, PPV and NPV were 95 %, 95 %, 93 % and 97 % (per-vessel: 89 %,98 %, 88 % and 98 %). Knowing the results of automated interpretation did not improve the performance of expert readers. Automated off-line post-processing of coronary CT angiography shows adequate sensitivity, but relatively low specificity in coronary stenosis detection. It does not increase accuracy of expert interpretation. Failure of post-processing in 10 % of all patients necessitates additional manual image work-up. (orig.)

  14. Sensitivity and accuracy of thallium-201 myocardial scintigraphy in the detection of coronary artery and myocardial disease

    International Nuclear Information System (INIS)

    Loesse, B.; Kroenert, H.; Rafflenbeul, D.; Feinendegen, L.E.; Loogen, F.; Duesseldorf Univ.

    1979-01-01

    169 patients (154 men, 15 women, mean age 49.5 years, range 27 to 64 years) were studied by means of 201-Thallium myocardial scintigraphy (201-Tl) and coronary angiography. According to the coronarangiogram, 130 patients had coronary artery disease (CAD): 53 a 1-vessel CAD, 29 a 2-vessel CAD, 48 a 3-vessel CAD. 39 patients had normal or less than 50% stenosed coronary arteries, but only 13 of these patients had also a normal ventriculogram, whereas 26 had an abnormal ventriculogram with local hypo-, a- or dyskinesia, diffuse hypokinesia, dilatation, or marked hypertrophy. The ramus interventicularis anterior (RIVA) was involved (stenosis of more than 50%) in 117 cases, the ramus circumflexus (R. circ.) in 70 cases, and the right coronary artery (RCA) in 67 cases. 201-Tl was abnormal in 98% of all 130 patients with CAD, in 100% of 93 patients with prior infarction, and in 95% of 37 patients without prior infarction. The sensitivity of the rest and/or exercise ECG in the same patients was only 79%, 88% and 57%, respectively. 201-Tl was abnormal in all 26 patients with a pathologic ventriculogram in spite of normal coronary arteries. 201-Tl and ECG were normal in only 9 of the 13 patients (=69%) with normal coronary arteries and normal ventriculogram. Myocardial biopsy, however, performed in 2 of the other 4 patients disclosed in part severe degenerative changes which can possibly explain the abnormal findings of 201-Tl and ECG. Significantly, i.e. more than 50% stenosed RIVA was correctly detected by 201-Tl in 98%, R. circ. in 71%, and RCA in 91% of the cases. The specificity of 201-Tl was limited by the great number of patients with a pathologic ventriculogram combined with normal coronary arteries. (orig.) [de

  15. Benign tracheobronchial stenoses: changes in short-term and long-term pulmonary function testing after expandable metallic stent placement.

    Science.gov (United States)

    Gotway, Michael B; Golden, Jeffrey A; LaBerge, Jeanne M; Webb, W Richard; Reddy, Gautham P; Wilson, Mark W; Kerlan, Robert K; Gordon, Roy L

    2002-01-01

    To determine the short- and long-term improvement in airflow dynamics in patients undergoing tracheobronchial stent placement for benign airway stenoses. Twenty-two patients underwent 34 tracheal and/or bronchial stent placement procedures for benign airway stenoses and had the results of pulmonary function tests available. Stent placement indications included bronchomalacia after lung transplantation (n = 11), postintubation stenoses (n = 6), relapsing polychondritis (n = 2), and 1 each of tracheomalacia, tracheal compression, and histoplasmosis. Six patients underwent more than one stent placement procedure (range: 2-7 procedures). The mean forced expiratory volume in one second (FEV(1) ), forced expiratory flow rate in the midportion of the forced vital capacity curve (FEF(25-75) ), forced vital capacity, and peak flow (PF) rate obtained before stent placement were compared with those immediately after stent placement and with those measurements most remote from stent placement using the paired two-tailed test. All patients reported improved respiratory function immediately after stent placement. The mean FEV(1), FEF(25-75), and PF rate improved significantly (p stent placement. On long-term follow-up averaging 15 months after stent placement, these parameters declined despite patients' subjective sense of improvement. Segregating the population into transplant and nontransplant airway stenosis etiologies, however, FEF(25-75) and PF rate remained significantly improved (p = 0.045, p = 0.027, respectively), over the long term for the latter. FEV increased after subsequent stent placements for patients receiving multiple stents. Stent placement for benign tracheobronchial stenoses provides significant immediate improvement in airflow dynamics. Long-term improvement in airflow obstruction may be expected, and additional stent placements may further improve pulmonary function.

  16. Effects of Hyperthyroidism on Coronary Artery Disease: A Computed Tomography Angiography Study.

    Science.gov (United States)

    Beyer, Christoph; Plank, Fabian; Friedrich, Guy; Wildauer, Matthias; Feuchtner, Gudrun

    2017-10-01

    Changes in thyroid hormone concentration can negatively affect the cardiovascular system. Subclinical hyperthyroidism has been linked to an increase of cardiovascular heart disease, however, clinical effects and significance are still uncertain. Therefore, we analyzed coronary computed tomography angiographies of patients with overt and subclinical hyperthyroidism for quantitative parameters and plaque morphology. Seven hundred forty-four (47.1% female) patients who underwent coronary computed tomography angiography were stratified into 3 groups: 51 patients with overt, 74 patients with subclinical hyperthyroidism, and 619 patients with euthyroidism. Analysis included grades of stenosis (no stenosis = 0, mild 70%) and plaque types (noncalcified, mixed, and calcified), segment involvement score (SIS), noncalcified SIS, and high-risk plaque features (napkin ring sign, low attenuation plaque, spotty calcifications, positive remodelling). Patients with overt and subclinical hyperthyroidism had more high-grade stenoses (39.2% vs 37.8% vs 24.2%; P = 0.007) and a higher coronary calcium score (456.5 vs 199.5 vs 155.9; P hyperthyroidism, followed by those with subclinical hyperthyroidism, had the most high-risk plaque features: napkin ring (21.6% vs 9.5% vs 6.0%, P hyperthyroid patients. Patients with subclinical and overt hyperthyroidism showed more high-grade coronary stenoses, plaque burden, and high-risk plaque features than patients with euthyroidism, which indicates that an increase of thyroid hormones might lead to coronary vascular degeneration and plaque instability. Copyright © 2017 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  17. Adolescent Kawasaki disease: usefulness of 64-slice CT coronary angiography for follow-up investigation

    Energy Technology Data Exchange (ETDEWEB)

    Carbone, Iacopo; Cannata, David; Algeri, Emanuela; Galea, Nicola; Napoli, Alessandro; Catalano, Carlo; Passariello, Roberto; Francone, Marco [Sapienza University of Rome, Department of Radiological, Onchological and Anatomopathological Sciences, Policlinico Umberto I, Rome (Italy); De Zorzi, Andrea [Bambino Gesu Hospital, Cardiology Division, Rome (Italy); Bosco, Giovanna; D' Agostino, Rita [Sapienza University of Rome, Unit of Paediatric Cardiology, Policlinico Umberto I, Rome (Italy); Menezes, Leon [University College of London, Institute of Nuclear Medicine, London (United Kingdom)

    2011-09-15

    Kawasaki disease (KD) is a systemic vasculitis that mainly affects coronary arteries in children, and requires regular follow-up from the time of diagnosis. To evaluate the feasibility of 64-slice CT angiography (CTA) for follow-up of patients with KD using previously performed invasive catheter coronary angiography (CCA) as reference standard. The study group comprised 12 patients (age 17.6 {+-} 2.9 years, mean{+-}SD) with a diagnosis of KD and a previously performed CCA (interval, 32.6 {+-} 13.5 months) who underwent 64-slice cardiac CTA. The quality of the images for establishing the presence of coronary abnormalities was determined by two observers. The CTA findings were compared with those from the prior CCA. Adequate image quality was obtained in all patients. Mean effective dose for CTA was 6.56 {+-} 0.95 mSv. CTA allowed accurate identification, characterization and measurement of all coronary aneurysms (n = 32), stenoses (n = 3) and occlusions (n = 9) previously demonstrated by CCA. One patient with disease progression went on to have percutaneous coronary intervention. Coronary lesions were reliably evaluated by 64-slice CTA in the follow-up of compliant patients with KD, reducing the need for repeated diagnostic invasive CCA. Hence, in an adequately selected patient population, the role of CCA could be limited almost only to therapeutic procedures. (orig.)

  18. Clinical aspects of coronary heart diseases without myocardial infarction and in the chronic infarction phase

    International Nuclear Information System (INIS)

    Kober, G.

    1984-01-01

    Reductions in coronary vessel diameters of more than 50% are usually caused by atherosclerosis, seldom by predominant spasme. They can lead via an inadequate myocardial perfusion to angina pectoris. Whereas in patients with organic coronary stenoses exertional angina is typical, patients with coronary spasms usually tend to angina at rest. Depending on the symptoms, a stable or unstable angina can be distinguished from the status anginosus and a variant form of angina. During anginal attacks signs of myocardial ischemia can often be seen in the electrocardiogram. This applies to patients with and without earlier myocardial infarctions. When pathologic ECG-changes can already be seen in the ECG at rest, difficulties often arise during evaluation of the exercise-ECG. In those cases, diagnosis can be improved by additional investigations, especially with radionuclear techniques. For a conclusive diagnosis, left heart catheterization and a functional coronary angiography is necessary. Coronary heart disease can be treated either by drug therapy, coronary angioplasty or bypass surgery. The same diagnostic procedures are suitable for the evaluation of a therapeutical success and for primary diagnosis. (orig.) [de

  19. Extra-anatomic bypass for recurrent abdominal aortic and renal in-stent stenoses following radiotherapy for neuroblastoma.

    Science.gov (United States)

    Luehr, Maximilian; Siepe, Matthias; Beyersdorf, Friedhelm; Schlensak, Christian

    2009-04-01

    We describe the case of an 11-year-old girl with an abdominal neuroblastoma which was operated and intraoperatively irradiated nine years ago. After six years, she developed stenoses of the infrarenal abdominal aorta and both renal arteries. Initial treatment of the stenosed vessels comprised endovascular balloon dilatations and repeated stent-graft implantations, including drug eluting stents. However, severe in-stent stenoses occurred during follow-up and the girl developed acute renal failure. Open surgery was performed with two extra-anatomic bypasses, a thoracic-to-abdominal aortic bypass and a left iliac-to-renal bypass, on an urgent basis. The postoperative course was uneventful and the patient was discharged home two weeks after the operation with full recovery of renal function. We conclude that endovascular stent-graft placement in children can only be a palliative treatment due to outgrowing of the stent-graft and the potential risk of re-stenosis, especially after a history of irradiation. Vascular surgery with placement of extra-anatomic bypasses will provide a definite treatment.

  20. Treatment of symptomatic high-grade intracranial stenoses with the balloon-expandable Pharos stent: initial experience

    International Nuclear Information System (INIS)

    Kurre, W.; Berkefeld, J.; Mesnil de Rochemont, R. du; Sitzer, M.; Neumann-Haefelin, T.

    2008-01-01

    We report our first clinical experience with a CE-marked flexible monorail balloon-expandable stent for treatment of high-grade intracranial stenoses. Between April 2006 and November 2007 21 patients with symptomatic intracranial stenoses (>70%) were treated with the PHAROS stent. In seven patients, the procedure was performed during acute stroke intervention. Procedural success, clinical complication rates and mid-term follow-up data were prospectively recorded. During a median follow-up period of 7.3 months one additional patient died of an unknown cause 3 months after the intervention. A patient with a significant residual stenosis presented with a new stroke after further progression of the residual stenosis. None of the successfully treated patients experienced ipsilateral stroke. Recanalization of intracranial stenoses with the balloon-expandable Pharos stent is technically feasible. The periprocedural complication rate and mid-term follow-up results were in the range of previously reported case series. This pilot study was limited by the small sample size and severe morbidity of the included patients. Final evaluation of the efficacy of Pharos stent treatment demands further investigation. (orig.)

  1. Treatment of intracranial atherosclerotic stenoses with balloon dilatation and self-expanding stent deployment (WingSpan)

    Energy Technology Data Exchange (ETDEWEB)

    Henkes, H. [Robert Janker Klinik, Bonn (Germany); Alfried Krupp Krankenhaus, Klinik fuer Radiologie und Neuroradiologie, Essen (Germany); Miloslavski, E.; Lowens, S.; Reinartz, J. [Robert Janker Klinik, Bonn (Germany); Liebig, T.; Kuehne, D. [Alfried Krupp Krankenhaus, Klinik fuer Radiologie und Neuroradiologie, Essen (Germany)

    2005-03-01

    The endovascular treatment of atherosclerotic intracranial arterial stenoses has previously been based on balloon dilatation or the deployment of a balloon expandable stent. Both methods have advantages (balloon: flexibility; balloon expandable stent: high radial force) and drawbacks (balloon: risk of elastic recoil and dissection; balloon expandable stent: limited flexibility, risk of injury to the vessel due to excessive straightening, overexpansion at ends of stent). A new combination of balloon dilatation, followed by the deployment of a self-expanding microstent has been applied in 15 patients with atherosclerotic arterial stenoses, symptomatic despite medical treatment. An anatomically and clinically adequate result was achieved in all patients. The initial degree of stenosis was 72% (mean). Balloon dilatation resulted in an average residual stenosis of 54% (mean), reduced further to a mean of 38% after stent deployment. Arterial dissection, occlusion of the target artery or symptomatic distal emboli was not encountered. In one patient, a side branch occlusion occurred after dilatation of a M1 stenosis, with complete neurological recovery. All patients were either stable or improved 4 weeks after the treatment. Recurrent TIA did not occur in any patient. Balloon dilatation and subsequent deployment of a self-expandable stent for the treatment of symptomatic intracranial arterial stenoses combines the advantages of both techniques and allows a rapid, clinically effective and technically safe treatment of these frequently challenging lesions. (orig.)

  2. Treatment of intracranial atherosclerotic stenoses with balloon dilatation and self-expanding stent deployment (WingSpan)

    International Nuclear Information System (INIS)

    Henkes, H.; Miloslavski, E.; Lowens, S.; Reinartz, J.; Liebig, T.; Kuehne, D.

    2005-01-01

    The endovascular treatment of atherosclerotic intracranial arterial stenoses has previously been based on balloon dilatation or the deployment of a balloon expandable stent. Both methods have advantages (balloon: flexibility; balloon expandable stent: high radial force) and drawbacks (balloon: risk of elastic recoil and dissection; balloon expandable stent: limited flexibility, risk of injury to the vessel due to excessive straightening, overexpansion at ends of stent). A new combination of balloon dilatation, followed by the deployment of a self-expanding microstent has been applied in 15 patients with atherosclerotic arterial stenoses, symptomatic despite medical treatment. An anatomically and clinically adequate result was achieved in all patients. The initial degree of stenosis was 72% (mean). Balloon dilatation resulted in an average residual stenosis of 54% (mean), reduced further to a mean of 38% after stent deployment. Arterial dissection, occlusion of the target artery or symptomatic distal emboli was not encountered. In one patient, a side branch occlusion occurred after dilatation of a M1 stenosis, with complete neurological recovery. All patients were either stable or improved 4 weeks after the treatment. Recurrent TIA did not occur in any patient. Balloon dilatation and subsequent deployment of a self-expandable stent for the treatment of symptomatic intracranial arterial stenoses combines the advantages of both techniques and allows a rapid, clinically effective and technically safe treatment of these frequently challenging lesions. (orig.)

  3. Divergence-free smoothing for MRV data on stenosed carotid artery phantom flows

    Science.gov (United States)

    Im, Chaehyuk; Ko, Seungbin; Song, Simon

    2017-11-01

    Magnetic Resonance Velocimetry (MRV) is a versatile technique for measuring flow velocity using an MRI machine. It is frequently used for visualization and analysis of blood flows. However, it is difficult to accurately estimate hemodynamics parameters like wall shear stress (WSS) and oscillatory shear index (OSI) due to its low spatial resolution and low signal-to-noise ratio. We suggest a divergence-free smoothing (DFS) method to correct the erroneous velocity vectors obtained with MRV and improve the estimation accuracy of those parameters. Unlike previous studies on DFS for a wall-free flow, we developed a house code to apply a DFS method to a wall-bounded flow. A Hagen-Poiseuille flow and stenosed carotid artery phantom flows were measured with MRV. Each of them was analyzed for validation of the DFS code and confirmation on the accuracy improvement of hemodynamic parameters. We will discuss the effects of DFS on the improvement of the estimation accuracy of velocity vectors, WSS, OSI and etc in detail This work was supported by the National Research Foundation of Korea(NRF) Grant funded by the Korea government(MSIP) (No. 2016R1A2B3009541).

  4. Relationship between transit time and mechanical properties of a cell through a stenosed microchannel.

    Science.gov (United States)

    Ye, Ting; Shi, Huixin; Phan-Thien, Nhan; Lim, Chwee Teck; Li, Yu

    2018-01-24

    The changes in the mechanical properties of a cell are not only the cause of some diseases, but can also be a biomarker for some disease states. In recent times, microfluidic devices with built-in constrictions have been widely used to measure these changes. The transit time in such devices, defined as the time that a cell takes to pass through a constriction, has been found to be a crucial factor associated with the cell mechanical properties. Here, we use smoothed dissipative particle dynamics (SDPD), a particle-based numerical method, to explore the relationship between the transit time and mechanical properties of a cell. Three expressions of the transit time are developed from our simulation data, with respect to the stenosed size of constrictions, the shear modulus and bending modulus of cells, respectively. We show that a convergent constriction (the inlet is wider than the outlet), and a sharp-corner constriction (the constriction outlet is narrow) are better in identifying the differences in the transit time of cells. Moreover, the transit time increases and gradually approaches a constant as the shear modulus of cells increases, but increases first and then decreases as the bending modulus increases. These results suggest that the mechanical properties of cells can indeed be measured by analyzing their transit time, based on the recommended microfluidic device.

  5. Numerical Investigation of Oxygenated and Deoxygenated Blood Flow through a Tapered Stenosed Arteries in Magnetic Field.

    Directory of Open Access Journals (Sweden)

    M Y Abdollahzadeh Jamalabadi

    Full Text Available Current paper is focused on transient modeling of blood flow through a tapered stenosed arteries surrounded a by solenoid under the presence of heat transfer. The oxygenated and deoxygenated blood are considered here by the Newtonian and Non-Newtonian fluid (power law and Carreau-Yasuda models. The governing equations of bio magnetic fluid flow for an incompressible, laminar, homogeneous, non-Newtonian are solved by finite volume method with SIMPLE algorithm for structured grid. Both magnetization and electric current source terms are well thought-out in momentum and energy equations. The effects of fluid viscosity model, Hartmann number, and magnetic number on wall shear stress, shearing stress at the stenosis throat and maximum temperature of the system are investigated and are optimized. The current study results are in agreement with some of the existing findings in the literature and are useful in thermal and mechanical design of spatially varying magnets to control the drug delivery and biomagnetic fluid flows through tapered arteries.

  6. Simulations of Magnetohemodynamics in Stenosed Arteries in Diabetic or Anemic Models

    Directory of Open Access Journals (Sweden)

    Aiman Alshare

    2016-01-01

    Full Text Available Pulsatile flow simulations of non-Newtonian blood flow in an axisymmetric multistenosed artery, subjected to a static magnetic field, are performed using FLUENT. The influence of artery size and magnetic field intensity on transient wall shear stress, mean shear stress, and pressure drop is investigated. Three different types of blood, namely, healthy, diabetic, and anemic are considered. It is found that using Newtonian viscosity model of blood in contrast to Carreau model underestimates the pressure drop and wall shear stress by nearly 34% and 40%, respectively. In addition, it is found that using a magnetic field increases the pressure drop by 15%. Generally, doubling the artery diameter reduces the wall shear stress approximately by 1.6 times. Also increasing the stenosis level from moderate to severe results in reduction of the shear stress by 1.6 times. Furthermore, doubling the diameter of moderately stenosed artery results in nearly 3-fold decrease in pressure drop. It is also found that diabetic blood results in higher shear stress and greater pressure drop in comparison to healthy blood, whereas anemic blood has a decreasing effect on both wall shear stress and pressure drop in comparison to healthy blood.

  7. Actual review of diagnostics and endovascular therapy of intracranial arterial stenoses

    International Nuclear Information System (INIS)

    Gizewski, E.R.; Weber, R.; Forsting, M.

    2011-01-01

    Approximately 6 - 50 % of all ischemic strokes are caused by intracranial arterial stenosis (IAS). Despite medical prevention, patients with symptomatic IAS have a high annual risk for recurrent ischemic stroke of about 12 %, and up to 19 % in the case of high-grade IAS (≥ 70 %). Digital subtraction angiography remains the gold standard for the diagnosis and grading of IAS. However, noninvasive imaging techniques including CT angiography, MR angiography, or transcranial Doppler and duplex ultrasound examinations are used in the clinical routine to provide additional information about the brain structure and hemodynamic. However, for technical reasons, the grading of stenoses is sometimes difficult and inaccurate. To date, aspirin is recommended as the treatment of choice in the prevention of recurrent ischemic stroke in patients with IAS. IAS patients who suffer a recurrent ischemic stroke or transient ischemic attack while taking aspirin can be treated with endovascular stenting or angioplasty in specialized centers. The periprocedural complication rate of these endovascular techniques is about 2 - 7 % at experienced neuro-interventional centers. The rate of re-stenosis is reported between 10 and 40 % depending on patient age and stenosis location. Further randomized studies comparing medical secondary prevention and endovascular therapy are currently being performed. With regard to the improvement of endovascular methods and lower complication rates, the indication for endovascular therapy in IAS could be broadened especially for stenosis in the posterior circulation. (orig.)

  8. Haemodynamic study of Flow in concentric and eccentric stenosed carotid Artery

    Directory of Open Access Journals (Sweden)

    Khader S. M. Abdul

    2018-01-01

    Full Text Available Study of flow through arteries is gaining importance in the recent times due to onset of several cardio-vascular diseases like atherosclerosis (block in artery, aneurysms (bulging of artery, hypertension etc. The application of CFD will be useful in demonstrating the underlying mechanism of flow past the diseased arteries. In the present study, initially an approximate eccentric and concentric 50% stenosed carotid model is generated in ANSYS 12.0 based on patient data obtained from ultrasound Doppler scan. Later the percentage of stenosis is increased to 60%, 70%, 80% and 90% in both the cases. A transient analysis has been performed for several pulse cycles in ANSYS FLOTRAN for various percentage cases. The results obtained from ECN and CCN cases are compared to observe the changes in flow behavior in the downstream of stenosis as compared with normal case. The formation of vortices and flow separation zone in downstream in eccentric case is higher than in concentric case. Comparison of results concludes that, with the increase in severity of stenosis, the flow changes abruptly causing an increase in velocity and WSS at throat region. The simulation results obtained agree well with clinically observed data and available literature.

  9. Complications after tracheal and cricotracheal resection and anastomosis for inflammatory and neoplastic stenoses.

    Science.gov (United States)

    Piazza, Cesare; Del Bon, Francesca; Paderno, Alberto; Grazioli, Paola; Mangili, Stefano; Lombardi, Davide; Nicolai, Piero; Peretti, Giorgio

    2014-11-01

    This study aimed to evaluate complications and success rates of tracheal resection and anastomosis (TRA) and cricotracheal resection and anastomosis (CTRA) in patients treated in 2 academic institutions. Retrospective charts review of 137 patients submitted to TRA/CTRA. Fifty (36.5%) had neoplastic (group A) and 87 (63.5%) benign (group B) stenoses. Using univariate analysis, age, medical comorbidities, previous radiotherapy, type of TRA/CTRA, association with neck dissection and thyroidectomy, length of resected airway, and preoperative tracheotomy were evaluated to identify factors predictive of complications and outcomes. The mean length of resected airway was 2.7 and 3 cm in groups A and B, respectively. Overall decannulation and complication rates for group A were 96% and 36%, and 99% and 46% for group B, respectively. Length of airway resected and presence of preoperative tracheotomy had a statistically significant effect on major surgical complications. Age older than 70 and cardiovascular and pulmonary comorbidities were significantly associated with the incidence of major medical complications. No statistically significant difference was found considering the complication rates of group A versus group B. Even though the overall success rate of TRA/CTRA is high, it should always be regarded as a major surgical procedure with a non-negligible incidence of complications. © The Author(s) 2014.

  10. [Actual review of diagnostics and endovascular therapy of intracranial arterial stenoses].

    Science.gov (United States)

    Gizewski, E R; Weber, R; Forsting, M

    2011-02-01

    Approximately 6 - 50% of all ischemic strokes are caused by intracranial arterial stenosis (IAS). Despite medical prevention, patients with symptomatic IAS have a high annual risk for recurrent ischemic stroke of about 12%, and up to 19% in the case of high-grade IAS (≥ 70%). Digital subtraction angiography remains the gold standard for the diagnosis and grading of IAS. However, noninvasive imaging techniques including CT angiography, MR angiography, or transcranial Doppler and duplex ultrasound examinations are used in the clinical routine to provide additional information about the brain structure and hemodynamic. However, for technical reasons, the grading of stenoses is sometimes difficult and inaccurate. To date, aspirin is recommended as the treatment of choice in the prevention of recurrent ischemic stroke in patients with IAS. IAS patients who suffer a recurrent ischemic stroke or transient ischemic attack while taking aspirin can be treated with endovascular stenting or angioplasty in specialized centers. The periprocedural complication rate of these endovascular techniques is about 2 - 7% at experienced neuro-interventional centers. The rate of re-stenosis is reported between 10 and 40% depending on patient age and stenosis location. Further randomized studies comparing medical secondary prevention and endovascular therapy are currently being performed. With regard to the improvement of endovascular methods and lower complication rates, the indication for endovascular therapy in IAS could be broadened especially for stenosis in the posterior circulation. © Georg Thieme Verlag KG Stuttgart · New York.

  11. No gender differences in prognosis and preventive treatment in patients with AMI without significant stenoses

    DEFF Research Database (Denmark)

    Hansen, Kim; Hvelplund, Anders; Abildstrøm, Steen Zabell

    2011-01-01

    : By compiling data from Danish registries, we identified 20,800 patients hospitalized with AMI during 2005-2007. We included the 834 women and 761 men without significant stenoses on CAG who were discharged and alive after 60 days. Main outcome measures: All-cause mortality, recurrent AMI, and redeeming...... a prescription for a lipid-lowering drug, beta-blocker, clopidogrel, or aspirin within 60 days of discharge. Results: During follow-up, 97 women and 60 men died, resulting in a crude female/male hazard ratio (HR) of 1.51 (95% CI 1.09-2.08). After adjustment for age, time-period, and comorbidity, the gender...... difference was attenuated (HR 1.22, 95% CI 0.86-1.72). AMI recurrence was experienced by 28 women and 29 men with a female/male HR 0.88 (95% CI 0.52-1.48). After multivariable adjustment results were similar (HR 0.84, 95% CI 0.50-1.43). More women than men redeemed a prescription for lipid-lowering drugs...

  12. Integral diagnosis of coronary atherosclerosis by coronary multidetector computed tomography and by invasive coronary angiography

    International Nuclear Information System (INIS)

    Llerena Rojas, Luis Roberto; Llerena Rojas, Lorenzo D; Mendoza Rodriguez, Vladimir

    2013-01-01

    Coronary angiography by multidetector computed tomography (CMDCT) visualizes the wall and lumen of coronary arteries. Invasive coronary angiography (INVCA) only visualizes the arterial lumen but with better resolution

  13. Flow patterns from metallic vascular endoprostheses: in vitro results

    Energy Technology Data Exchange (ETDEWEB)

    Mueller-Huelsbeck, S.; Grimm, J.; Jahnke, T.; Haeselbarth, G.; Heller, M. [Dept. of Radiology, University Hospital, Kiel (Germany)

    2001-05-01

    The aim of this study was to determine flow characteristics and pressure gradients of different balloon- and self-expandable stents in an in vitro flow-model. Seven vascular stents (Bridge, Cragg, Memotherm, Palmaz PS 784, Sinus, Symphony, Wallstent), equal in length (60 mm) and diameter (10 mm), were deployed in a closed flow model. The inner diameter of the tube measured 9 mm. Flow at 1.5 and 6 l/min was applied. Flow patterns were visualized by anionic particles illuminated with two helium-neon lasers. Late laminary flow characteristics and pre- /post-stent pressure gradients were determined in either expanded stent, 25 and 50 % tube stenosis. Stent implantation induced a decrease of laminary flow when compared with an unstented tube with and without concentric 25 % stenosis (p < 0.01) at all flow rates and an increase of pressure gradients when compared with an unstented tube for a flow rate of 6 l/min and all stenoses (p < 0.01). At 1.5 l/min most stents revealed no significant change of pressure gradient, the highest gradient measured 4.0 mmHg. Sinus permitted maximum (expanded: 82.1 % and 76.9 % at 25 % stenosis at 1.5 l/min; p < 0.01) and Palmaz minimum of laminary flow at all flow rates and stenoses (70.2 and 52.4 % at 25 % stenosis at 1.5 l/min; p < 0.01). At 6 l/min, when completely expanded, Sinus is equal to Bridge and Memotherm; in 25 % stenosis Sinus is equal to Bridge, Memotherm, and additionally to Cragg and Wall. None of the endoprostheses revealed laminary flow at 50 % stenosis. Inadequate stent deployment bears the risk of creating less laminary flow and pressure gradients. Since flow disturbances and pressure gradients may influence neointimal hyperplasia, stent design and completeness of stent expansion are important factors regarding the appearance of thrombus formation and postinterventional restenosis. (orig.)

  14. Qual o erro da angiografia na definição de isquemia miocárdica durante intervenções coronarianas percutâneas? What is the angiography error when defining myocardial ischemia during percutaneous coronary interventions?

    Directory of Open Access Journals (Sweden)

    Fernando Mendes Sant'Anna

    2008-09-01

    Full Text Available FUNDAMENTO: A angiografia vem sendo utilizada como padrão de referência para definição de doença arterial coronariana (DAC, embora suas limitações sejam conhecidas. O valor da medida do fluxo fracionado de reserva do miocárdio (FFR na avaliação da DAC está bem estabelecido. OBJETIVO: O objetivo deste estudo é avaliar a acurácia da angiografia em definir as lesões isquêmicas e sua correlação com o FFR. MÉTODOS: Duzentos e cinqüenta pacientes foram incluídos no estudo (471 vasos. Todas as estenoses > 50% pela estimativa visual da angiografia (EVA foram avaliadas medindo-se o FFR. Se o FFR 0,75 a lesão não foi tratada. As lesões foram divididas em moderadas (BACKGROUND: The angiography has been used as a reference standard to define coronary artery disease (CAD, although its limitations are well-known. The significance of the myocardial fractional flow reserve (FFR in the assessment of CAD is well established. OBJECTIVE: The aim of this study was to evaluate the accuracy of angiography when defining ischemic lesions and its correlation with FFR. METHODS: Two hundred and fifty consecutive patients (471 arteries were included in this study. All stenoses > 50% at the angiography visual estimate (AVE were assessed by FFR measurements. When FFR was 0.75, no interventional treatment was carried out. Offline quantitative coronary angiography (QCA was performed in all stenoses, which were divided in intermediate (< 70% - 327 and severe (125. The correlation coefficients between the diameter of the stenosis (%DS and FFR and the accuracy of VA of the angiography when assessing ischemia were determined. RESULTS: FFR could be obtained in 452 lesions (96%. Mean %DS and FFR were 56 ± 8% and 0.74 and 76 ± 6% and 0.48 for moderate and severe stenoses, respectively. Concordance between QCA and FFR was poor, especially in intermediate stenoses (Spearman's rho = - 0.33, p<0.0001. Visual assessment resulted in an accuracy of 57% and 96% in

  15. SPECT-CT in the diagnosis of coronary artery disease; SPECT-CT in der Diagnostik der koronaren Herzerkrankung

    Energy Technology Data Exchange (ETDEWEB)

    Hacker, M. [Klinik und Poliklinik fuer Nuklearmedizin, Klinikum der Univ. Muenchen (Germany)

    2006-09-15

    Two-dimensional invasive coronary angiography (ICA), although showing high temporal and spatial resolution, is neither able to predict the physiologic relevance of a stenosis nor able to determine the prognosis of both symptomatic and asymptomatic patients. Therefore, the ICA can hardly represent the sole gold standard in clinical decision making. Additionally, the small but distinct morbidity and mortality rate of this method and the inconvenience of patients undergoing ICA have strengthened the search for a non-invasive alternative. Recent publications have shown high accuracy for spiral computed tomography (MDCT) angiography acquired with a 64-slice CT scanner compared to ICA in detecting 'obstructive' coronary artery disease, defined as stenosis of more than 50%. Otherwise, although well known limitations of MDCT like motion artifacts or severe vessel calcifications could be clearly reduced with the newest scanner generation, this technique lacks of delivering exact lumen quantification compared to ICA in a clinical setting. Furthermore, there is evidence that exact quantification of coronary artery stenoses is of minor impact on clinical decision making, if lesion location and functional status are known. A first publication showed that combined imaging of MDCT angiography and PET myocardinal perfusion scanning with [{sup 13}N]ammonia was feasible with an integrated PET/CT scanner and reported high sensitivity and specificity to detect hemodynamically relevant coronary artery stenoses compared to the combination of PET plus ICA. However, PET perfusion tracers are not widely available at present and the well accepted reference for detecting myocardial ischemia, based on numerous publications, is myocardial perfusion SPECT (MPI). MPI is an established method for the non-invasive assessment of functional significance of coronary stenoses and delivers valuable information for risk stratification. Patients with stable angina and normal stress sestamibi

  16. Numerical investigation of MHD flow of blood and heat transfer in a stenosed arterial segment

    Energy Technology Data Exchange (ETDEWEB)

    Majee, Sreeparna; Shit, G.C., E-mail: gcs@math.jdvu.ac.in

    2017-02-15

    A numerical investigation of unsteady flow of blood and heat transfer has been performed with an aim to provide better understanding of blood flow through arteries under stenotic condition. The blood is treated as Newtonian fluid and the arterial wall is considered to be rigid having deposition of plaque in its lumen. The heat transfer characteristic has been analyzed by taking into consideration of the dissipation of energy due to applied magnetic field and the viscosity of blood. The vorticity-stream function formulation has been adopted to solve the problem using implicit finite difference method by developing well known Peaceman–Rachford Alternating Direction Implicit (ADI) scheme. The quantitative profile analysis of velocity, temperature and wall shear stress as well as Nusselt number is carried out over the entire arterial segment. The streamline and temperature contours have been plotted to understand the flow pattern in the diseased artery, which alters significantly in the downstream of the stenosis in the presence of magnetic field. Both the wall shear stress and Nusselt number increases with increasing magnetic field strength. However, wall shear stress decreases and Nusselt number enhances with Reynolds number. The results show that with an increase in the magnetic field strength upto 8 T, does not causes any damage to the arterial wall, but the study is significant for assessing temperature rise during hyperthermic treatment. - Highlights: • Fully numerical simulation is carried out for MHD blood flow in stenosed artery. • Dissipation of energy due to both magnetic field and blood viscosity is considered. • Strong Vortices are observed at the downstream of the stenosis in the arterial wall. • Flow reversal of blood is reduced by applying sufficient magnetic field strength. • Isothermal lines are strongly distorted in the presence of magnetic field strength.

  17. Resting Pd/Pa and haemodynamic relevance of coronary stenosis as evaluated by fractional flow reserve.

    Science.gov (United States)

    De Luca, Giuseppe; Verdoia, Monica; Barbieri, Lucia; Marino, Paolo; Suryapranata, Harry

    2018-03-01

    Fractional flow reserve (FFR) currently represents the gold standard in the evaluation of the haemodynamic relevance of coronary stenoses. However, both intracoronary and intravenous adenosine may be tolerated poorly by some patients. Therefore, considerable interest had been focused in the last few years on new adenosine-free indexes to define the haemodynamic relevance of coronary stenoses. So far, few data have been reported on resting Pd/Pa and its correlation with FFR as evaluated with high-dose intracoronary adenosine administration, which is the aim of the current study. FFR was assessed in 120 patients with 137 intermediate lesions during cardiac catheterization by a pressure-recording guidewire (PrimeWire). FFR was calculated as the ratio of the distal coronary pressure to the aortic pressure at hyperaemia. Intracoronary doses of adenosine were administered up to 720 μg as intracoronary boli. Exclusion criteria were as follows: (a) allergy to adenosine; (b) baseline bradycardia (heart rate values and increased the percentage of patients showing an FFR less than 0.80. Resting Pd/Pa showed good accuracy in the identification of patients with significant FFR values (value in the prediction of a positive FFR value. A value up to 0.88 was associated with a 100% positive predictive value, whereas a value of at least 0.95 was associated with a 95% negative predictive value. This study showed that in intermediate lesions, resting Pd/Pa was related linearly to FFR. We identified 0.93 as the best cut-off value in the prediction of haemodynamically significant coronary stenosis as evaluated by FFR. However, cut-off values of 0.88 and 0.95 could provide the maximal predictive positive and negative values, suggesting the additional use of FFR only in patients with resting values within this range.

  18. Relationship between aortic valve calcification and the severity of coronary atherosclerotic disease.

    Science.gov (United States)

    Qian, Juying; Chen, Zhangwei; Ge, Junbo; Ma, Jianying; Chang, Shufu; Fan, Bing; Liu, Xuebo; Ge, Lei

    2010-07-01

    Aortic valve calcification (AVC), which has been confirmed to be associated with various risk factors of cardiac disease, is common in the elderly and associated with increased cardiovascular mortality. It has been hypothesized that AVC is associated with coronary atherosclerotic disease, and its severity. Between July 2007 and November 2007, a total of 235 patients with chest pain or chest distress were admitted to the authors' institution for coronary angiography. The severity of coronary atherosclerotic disease (CAD) was evaluated by the Gensini score, the number of stenosed vessels, and the prevalence of total occlusion. All patients underwent transthoracic echocardiography to detect AVC. Patients with CAD had a higher prevalence of AVC than those without CAD (44% versus 26%, p = 0.005). Likewise, the prevalence of AVC was significantly higher in patients with a higher Gensini score than in those with a lower score. Patients with AVC had a higher prevalence of CAD, and higher Gensini scores and numbers of stenosed coronary arteries, even after stratification by age (65 years). On multivariable logistic regression analysis for CAD, the odds ratio (OR) of AVC was 2.315 (95% confidence interval (CI): 1.158-4.629, p = 0.018); this value was higher than that for total cholesterol (OR = 1.637, p = 0.008), lipoprotein-a (OR = 1.003, p = 0.015) and fibrinogen (OR = 1.009, p = 0.006), and marginally less than that for male gender (OR = 2.665, p = 0.005). Patients with AVC had a higher prevalence and greater severity of CAD.

  19. Diagnostic value of multislice computed tomography angiography in coronary artery disease: A meta-analysis

    International Nuclear Information System (INIS)

    Sun Zhonghua; Jiang Wen

    2006-01-01

    Purpose: To perform a meta-analysis of the diagnostic value of multislice CT (MSCT) angiography in the detection of coronary artery disease (CAD) when compared to conventional coronary angiography. Materials and methods: A search of PubMed and MEDLINE databases for English literature was performed. Only studies with at least 10 patients comparing MSCT angiography with conventional coronary angiography in the detection of CAD were included. Diagnostic value of MSCT angiography compared to coronary angiography was compared and analyzed at segment-, vessel- and patient-based assessment. Results: 47 studies (67 comparisons) met the criteria and were included in our study. Pooled overall sensitivity, specificity and 95% confidence interval for MSCT angiography in the detection of CAD were 83% (79%, 89%), 93% (91%, 96%) at segment-based analysis; 90% (87%, 94%), 87% (80%, 93%) at vessel-based analysis; and 91% (88%, 95%), 86% (81%, 92%) at patient-based analysis, respectively. Diagnostic accuracy of MSCT angiography in evaluating assessable segments was significantly improved with 64-slice scanners when compared to that with 4- and 16-slice scanners (p < 0.05). Conclusion: Our meta-analysis showed that MSCT angiography has potential diagnostic accuracy in the detection of CAD. Diagnostic performance of MSCT angiography has been significantly improved with the latest 64-slice CT, with resultant high qualitative and quantitative diagnostic accuracy. 16-slice CT was limited in spatial resolution which makes it difficult to perform quantitative assessment of coronary artery stenoses

  20. Development and characterization of a coronary polylactic acid stent prototype generated by selective laser melting.

    Science.gov (United States)

    Flege, Christian; Vogt, Felix; Höges, Simon; Jauer, Lucas; Borinski, Mauricio; Schulte, Vera A; Hoffmann, Rainer; Poprawe, Reinhart; Meiners, Wilhelm; Jobmann, Monika; Wissenbach, Konrad; Blindt, Rüdiger

    2013-01-01

    In-stent restenosis is still an important issue and stent thrombosis is an unresolved risk after coronary intervention. Biodegradable stents would provide initial scaffolding of the stenosed segment and disappear subsequently. The additive manufacturing technology Selective Laser Melting (SLM) enables rapid, parallel, and raw material saving generation of complex 3- dimensional structures with extensive geometric freedom and is currently in use in orthopedic or dental applications. Here, SLM process parameters were adapted for poly-L-lactid acid (PLLA) and PLLA-co-poly-ε-caprolactone (PCL) powders to generate degradable coronary stent prototypes. Biocompatibility of both polymers was evidenced by assessment of cell morphology and of metabolic and adhesive activity at direct and indirect contact with human coronary artery smooth muscle cells, umbilical vein endothelial cells, and endothelial progenitor cells. γ-sterilization was demonstrated to guarantee safety of SLM-processed parts. From PLLA and PCL, stent prototypes were successfully generated and post-processing by spray- and dip-coating proved to thoroughly smoothen stent surfaces. In conclusion, for the first time, biodegradable polymers and the SLM technique were combined for the manufacturing of customized biodegradable coronary artery stent prototypes. SLM is advocated for the development of biodegradable coronary PLLA and PCL stents, potentially optimized for future bifurcation applications.

  1. Patient-specific 3D hemodynamics modelling of left coronary artery under hyperemic conditions.

    Science.gov (United States)

    Kamangar, Sarfaraz; Badruddin, Irfan Anjum; Govindaraju, Kalimuthu; Nik-Ghazali, N; Badarudin, A; Viswanathan, Girish N; Ahmed, N J Salman; Khan, T M Yunus

    2017-08-01

    The purpose of this study is to investigate the effect of various degrees of percentage stenosis on hemodynamic parameters during the hyperemic flow condition. 3D patient-specific coronary artery models were generated based on the CT scan data using MIMICS-18. Numerical simulation was performed for normal and stenosed coronary artery models of 70, 80 and 90% AS (area stenosis). Pressure, velocity, wall shear stress and fractional flow reserve (FFR) were measured and compared with the normal coronary artery model during the cardiac cycle. The results show that, as the percentage AS increase, the pressure drop increases as compared with the normal coronary artery model. Considerable elevation of velocity was observed as the percentage AS increases. The results also demonstrate a recirculation zone immediate after the stenosis which could lead to further progression of stenosis in the flow-disturbed area. Highest wall shear stress was observed for 90% AS as compared to other models that could result in the rupture of coronary artery. The FFR of 90% AS is found to be considerably low.

  2. Escherichia coli Uropathogenesis In Vitro

    DEFF Research Database (Denmark)

    Andersen, Thomas E; Khandige, Surabhi; Madelung, Michelle

    2012-01-01

    -stage infection events have not been replicated in vitro. We have established an in vitro model of human bladder cell infection by the use of a flow chamber (FC)-based culture system, which allows investigation of steps subsequent to initial invasion. Short-term bacterial colonization on the FC-BEC layer led...... to rods that could invade other BECs. Hence, under growth conditions established to resemble those present in vivo, the elements of the proposed uropathogenic cascade were inducible in a human BEC model system. Here, we describe the model and show how these characteristics are reproduced in vitro....

  3. Coronary heart disease

    Science.gov (United States)

    Heart disease, Coronary heart disease, Coronary artery disease; Arteriosclerotic heart disease; CHD; CAD ... buildup of plaque in the arteries to your heart. This may also be called hardening of the ...

  4. A method to identify early ventricular dysfunction using resting gated blood pool scans (GBPS) in patients with coronary artery disease (CAD)

    International Nuclear Information System (INIS)

    Schwarzberg, R.J.; Seldin, D.W.; Johnson, L.L.; Alderson, P.O.

    1984-01-01

    To determine the sensitivity of regional 1st and 2nd time derivative (1DV, 2DV) images to assess ventricular function (VF) in CAD, the resting GBPS of 8 normal patients (pts) and 20 pts with CAD who had coronary angiography and contrast ventriculography (CV) were analyzed. The 1DV and 2DV of the systolic time-activity curve were determined for each left ventricular pixel in the GBPS. These values were displayed as functional images that were reviewed by three readers to determine the presence of regional abnormalities. No regional abnormalities were seen in the conventional GBPS or 1DV or 2DV images of the 8 normal pts. Regional GBPS and DV image abnormalities were seen in all 10 pts with CAD and abnormal wall motion by CV. The DV image abnormalities were in the distribution of 18/22 coronary arteries (CA) with ≥50% stenoses; 2 of these regions showed normal wall motion by CV and conventional GBPS. DV images were abnormal in 2/8 CAs without significant stenoses. In addition, regional DV image abnormalities were present in 9 of 10 pts with CAD who had normal wall motion and global ejection fraction by both CV and resting GBPS. These 10 pts showed regional abnormalities in the distribution of 13/15 CAs with significant stenoses and 2/15 CAs without such stenoses. The results suggest that time derivative functional images derived from resting GBPS provide a more sensitive means for detecting regional left ventricular dysfunction than several other current methods, especially in pts with mild CAD

  5. Noninvasive assessment of coronary artery disease by multislice spiral computed tomography using a new retrospectively ECG-gated image reconstruction technique. Comparison with angiographic results

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Yuichi; Matsumoto, Naoya; Kato, Masahiko [Nihon Univ., Tokyo (Japan). Surugadai Hospital] [and others

    2003-04-01

    The present study was designed to investigate the accuracy of multislice spiral computed tomography (MSCT) in detecting coronary artery disease, compared with coronary angiography (CAG), using a new retrospectively ECG-gated reconstruction method that reduced cardiac motion artifact. The study group comprised 54 consecutive patients undergoing MSCT and CAG. MSCT was performed using a SOMATOM Volume Zoom (4-detector-row, Siemens, Germany) with slice thickness 1.0 mm, pitch 1.5 (table feed: 1.5 mm per rotation) and gantry rotation time 500 ms. Metoprolol (20-60 mg) was administered orally prior to MSCT imaging. ECG-gated image reconstruction was performed with the reconstruction window (250 ms) positioned immediately before atrial contraction in order to reduce the cardiac motion artifact caused by the abrupt diastolic ventricular movement occurring during the rapid filling and atrial contraction periods. Following inspection of the volume rendering images, multiplanar reconstruction images and axial images of the left main coronary artery (LMCA), left anterior descending artery (LAD), left circumflex artery (LCx) and right coronary artery (RCA) were obtained and evaluated for luminal narrowing. The results were compared with those obtained by CAG. Of 216 coronary arteries, 206 (95.4%) were assessable; 10 arteries were excluded from the analysis because of severe calcification (n=4), stents (n=3) or insufficient contrast enhancement (n=3). The sensitivity to detect coronary stenoses {>=}50% was 93.5% and the specificity to define luminal narrowing <50% was 97.2%. The positive predictive value and the negative predictive value were 93.5% and 97.2%, respectively. The sensitivity was still satisfactory (80.6%) even when non-assessable arteries were included in the analysis. The new retrospectively ECG-gated reconstruction method for MSCT has excellent diagnostic accuracy in detecting significant coronary artery stenoses. (author)

  6. IVF-In Vitro Fertilization.

    Science.gov (United States)

    Kieffer, George H.

    1980-01-01

    Issues surrounding the controversial topic of in vitro fertilization and artificial manipulation of reproduction are discussed. The author examines the moral and ethical implications and presents results of a survey of various religious groups. (SA)

  7. Coronary CT angiography using 64 detector rows: methods and design of the multi-centre trial CORE-64

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Julie M.; Vavere, Andrea L.; Arbab-Zadeh, Armin; Bush, David E.; Lardo, Albert C.; Texter, John; Brinker, Jeffery; Lima, Joao A.C. [Johns Hopkins Hospital, Johns Hopkins University, Department of Medicine, Division of Cardiology, Baltimore, MD (United States); Dewey, Marc [Charite - Universitaetsmedizin Berlin, Medical School, Humboldt-Universitaet und Freie Universitaet zu Berlin, Department of Radiology, Berlin, PO Box 10098 (Germany); Rochitte, Carlos E.; Lemos, Pedro A. [University of Sao Paulo Medical School, Heart Institute (InCor), Sao Paulo (Brazil); Niinuma, Hiroyuki [Iwate Medical University, Department of Cardiology, Morioka (Japan); Paul, Narinder [Toronto General Hospital, Department of Medical Imaging, Toronto (Canada); Hoe, John [Medi-Rad Associates Ltd, CT Centre, Mt Elizabeth Hospital, Singapore (Singapore); Roos, Albert de [Leiden University Medical Center, Department of Radiology, Leiden (Netherlands); Yoshioka, Kunihiro [Iwate Medical University, Department of Radiology, Morioka (Japan); Cox, Christopher [Johns Hopkins Bloomberg School of Public Health, Department of Epidemiology, Baltimore, MD (United States); Clouse, Melvin E. [Harvard University, Department of Radiology, Beth Israel Deaconess, Boston, MA (United States)

    2009-04-15

    Multislice computed tomography (MSCT) for the noninvasive detection of coronary artery stenoses is a promising candidate for widespread clinical application because of its non-invasive nature and high sensitivity and negative predictive value as found in several previous studies using 16 to 64 simultaneous detector rows. A multi-centre study of CT coronary angiography using 16 simultaneous detector rows has shown that 16-slice CT is limited by a high number of nondiagnostic cases and a high false-positive rate. A recent meta-analysis indicated a significant interaction between the size of the study sample and the diagnostic odds ratios suggestive of small study bias, highlighting the importance of evaluating MSCT using 64 simultaneous detector rows in a multi-centre approach with a larger sample size. In this manuscript we detail the objectives and methods of the prospective ''CORE-64'' trial (''Coronary Evaluation Using Multidetector Spiral Computed Tomography Angiography using 64 Detectors''). This multi-centre trial was unique in that it assessed the diagnostic performance of 64-slice CT coronary angiography in nine centres worldwide in comparison to conventional coronary angiography. In conclusion, the multi-centre, multi-institutional and multi-continental trial CORE-64 has great potential to ultimately assess the per-patient diagnostic performance of coronary CT angiography using 64 simultaneous detector rows. (orig.)

  8. Fusion of CT coronary angiography and whole-heart dynamic 3D cardiac MR perfusion: building a framework for comprehensive cardiac imaging.

    Science.gov (United States)

    von Spiczak, Jochen; Manka, Robert; Gotschy, Alexander; Oebel, Sabrina; Kozerke, Sebastian; Hamada, Sandra; Alkadhi, Hatem

    2018-04-01

    The purpose of this work was to develop a framework for 3D fusion of CT coronary angiography (CTCA) and whole-heart dynamic 3D cardiac magnetic resonance perfusion (3D-CMR-Perf) image data-correlating coronary artery stenoses to stress-induced myocardial perfusion deficits for the assessment of coronary artery disease (CAD). Twenty-three patients who underwent CTCA and 3D-CMR-Perf for various indications were included retrospectively. For CTCA, image quality and coronary diameter stenoses > 50% were documented. For 3D-CMR-Perf, image quality and stress-induced perfusion deficits were noted. A software framework was developed to allow for 3D image fusion of both datasets. Computation steps included: (1) fully automated segmentation of coronary arteries and heart contours from CT; (2) manual segmentation of the left ventricle in 3D-CMR-Perf images; (3) semi-automatic co-registration of CT/CMR datasets; (4) projection of the 3D-CMR-Perf values on the CT left ventricle. 3D fusion analysis was compared to separate inspection of CTCA and 3D-CMR-Perf data. CT and CMR scans resulted in an image quality being rated as good to excellent (mean scores 3.5 ± 0.5 and 3.7 ± 0.4, respectively, scale 1-4). 3D-fusion was feasible in all 23 patients, and perfusion deficits could be correlated to culprit coronary lesions in all but one case (22/23 = 96%). Compared to separate analysis of CT and CMR data, coronary supply territories of 3D-CMR-Perf perfusion deficits were refined in two cases (2/23 = 9%), and the relevance of stenoses in CTCA was re-judged in four cases (4/23 = 17%). In conclusion, 3D fusion of CTCA/3D-CMR-Perf facilitates anatomic correlation of coronary lesions and stress-induced myocardial perfusion deficits thereby helping to refine diagnostic assessment of CAD.

  9. Assessment Of Coronary Arterial Stents By Multislice-CT Angiography

    International Nuclear Information System (INIS)

    Maintz, D.; Fallenberg, E. M.; Heindel, W.; Fischbach, R.; Grude, M.

    2003-01-01

    Purpose: To assess patency and lumen visibility of coronary artery stents by multislice-CT angiography (MSCTA) in comparison with conventional coronary angiography as the standard of reference. Material and Methods: 47 stents of 13 different types were evaluated in 29 patients. MSCTA was performed on a 4-slice scanner with a standard coronary protocol (detector collimation 4 x 1 mm; table feed 1.5 mm/rotation, 400 mAs, 120 kV). Image evaluation was performed by two readers who were blinded to the reports from the catheter angiography. MIP reconstructions were evaluated for image quality on a 4-point scale (1 = poor, 4 = excellent) and stent patency (contrast distal to the stent as an indirect patency sign). Axial images and multiplanar reformations through the stents were used for assessment of stent lumen visibility (measurement of the visible stent lumen diameter) and detection of relevant in-stent stenosis (50%). Results: Image quality was fair to good on average (score 2.64 ± 1.0) and depended on the heart rate (heart rate 45-60: average score 3.2, heart rate 61-70: average score 2.8, heart rate >71: average score 1.4). Thirty-seven stents were correctly classified as patent, 1 was correctly classified as occluded and 9 stents were not assessable due to insufficient image quality because of triggering artifacts. Parts of the stent lumen could be visualized in 30 cases. On average, 20-40% of the stent lumen diameter was visible. Twenty-five stents were correctly classified as having no stenosis, 1 was falsely classified as stenosed, 1 was correctly classified as occluded. In 20 stents lumen visibility was not sufficient for stenosis evaluation. Conclusion: Although the stent lumen may be partly visualized in most stents, a reliable evaluation of in-stent stenoses does not seem practical by 4-slice MSCT. Nevertheless, for stent patency evaluation, MS-CTA might provide valuable clinical information. With submillimeter MSCT (e.g. 16-slice scanners) and more

  10. Measurement of fractional flow reserve to guide decisions for percutaneous coronary intervention.

    Science.gov (United States)

    Siebert, Uwe; Bornschein, Bernhard; Schnell-Inderst, Petra; Rieber, Johannes; Pijls, Nico; Wasem, Jürgen; Klauss, Volker

    2008-08-27

    Coronary artery disease (CAD) is one of the leading causes of premature death in Germany. Percutaneous coronary interventions (PCI) are frequently performed in patients with angiographically intermediate stenoses. However, the necessity of PCI has not been proven for all patients. Pressure-based fractional flow reserve (FFR) is an invasive test that can be used to assess the functional significance of intermediate coronary stenoses in order to guide decisions on PCI. This health technology assessment (HTA) aims to evaluate (1) the diagnostic accuracy, (2) the risk-benefit trade-off and (3) the long-term cost-effectiveness of FFR measurement to guide the decision on PCI in patients with stable angina pectoris and intermediate coronary stenoses. We performed a literature search in medical and HTA databases. We used the DIMDI instruments (DIMDI = Deutsches Institut für Medizinische Dokumentation und Information/German Institute for Medical Information and Documentation) to assess study quality and to extract and summarize the information in evidence tables. We performed a meta-analysis to calculate the pooled overall estimate for sensitivity and specificity of FFR with 95% confidence intervals (95% CI). Individual studies' case numbers were used as weights. The influence of single studies and important covariates on the results was tested in sensitivity analyses. We developed the German Coronary Artery Disease Outcome Model (German CADOM), a decision-analytic Markov model, to estimate the long-term effectiveness and cost-effectiveness of FFR measurement in the context of the German healthcare system. Our literature search identified twelve studies relevant to this HTA-report including ten diagnostic accuracy studies of FFR measurement, one randomized clinical trial (RCT) investigating the clinical benefits of this technique as well as one economic evaluation. Pooled estimates for sensitivity and specificity were 81.7% (95% CI: 77.0-85.7%) and 78.7% (95% CI: 74

  11. Measurement of fractional flow reserve to guide decisions for percutaneous coronary intervention

    Directory of Open Access Journals (Sweden)

    Wasem, Jürgen

    2008-08-01

    Full Text Available Background: Coronary artery disease (CAD is one of the leading causes of premature death in Germany. Percutaneous coronary interventions (PCI are frequently performed in patients with angiographically intermediate stenoses. However, the necessity of PCI has not been proven for all patients. Pressure-based fractional flow reserve (FFR is an invasive test that can be used to assess the functional significance of intermediate coronary stenoses in order to guide decisions on PCI. Objectives: This health technology assessment (HTA aims to evaluate (1 the diagnostic accuracy, (2 the risk-benefit trade-off and (3 the long-term cost-effectiveness of FFR measurement to guide the decision on PCI in patients with stable angina pectoris and intermediate coronary stenoses. Methods: We performed a literature search in medical and HTA databases. We used the DIMDI instruments (DIMDI = Deutsches Institut für Medizinische Dokumentation und Information/German Institute for Medical Information and Documentation to assess study quality and to extract and summarize the information in evidence tables. We performed a meta-analysis to calculate the pooled overall estimate for sensitivity and specificity of FFR with 95% confidence intervals (95% CI. Individual studies’ case numbers were used as weights. The influence of single studies and important covariates on the results was tested in sensitivity analyses. We developed the German Coronary Artery Disease Outcome Model (German CADOM, a decision-analytic Markov model, to estimate the long-term effectiveness and cost-effectiveness of FFR measurement in the context of the German healthcare system. Results: Our literature search identified twelve studies relevant to this HTA-report including ten diagnostic accuracy studies of FFR measurement, one randomized clinical trial (RCT investigating the clinical benefits of this technique as well as one economic evaluation. Pooled estimates for sensitivity and specificity were 81

  12. The value of applying nitroglycerin in 3D coronary MR angiography with real-time navigation technique

    International Nuclear Information System (INIS)

    Hackenbroch, M.; Meyer, C.; Schmiedel, A.; Hofer, U.; Flacke, S.; Kovacs, A.; Schild, H.; Sommer, T.; Tiemann, K.; Skowasch, D.

    2004-01-01

    Purpose: Nitroglycerin administration results in dilation of epicardial coronary vessels and in an increase in coronary blood flow, and has been suggested to improve MR coronary angiography. This study evaluates systematically whether administration of nitroglycerin improves the visualization of coronary arteries and, as a result, the detection of coronary artery stenosis during free breathing 3D coronary MR angiography. Materials and Methods: Coronary MR angiography was performed in 44 patients with suspected coronary artery disease at a 1.5 Tesla System (Intera, Philips Medical Systems) (a) with and (b) without continuous administration of intravenous nitroglycerin at a dose rate of 2.5 mg/h, using an ECG gated gradient echo sequence with real-time navigator correction (turbo field echo, in-plane resolution 0.70 x 0.79 mm 2 , acquisition window 80 ms). Equivalent segments of the coronary arteries in the sequences with and without nitroglycerin were evaluated for visualized vessel length and diameter, qualitative assessment of visualization using a four point grading scale and detection of stenoses >50%. Catheter coronary angiography was used as a gold-standard. Results: No significant differences were found between scans with and without nitroglycerin as to average length of the contiguously visualized vessel length (p>0.05) and diameter (p>0.05). There was also no significant difference in the coronary MR angiography with and without nitroglycerin in the average qualitative assessment score of the visualization of LM, proximal LAD, proximal CX, and proximal and distal RCA (2.1±0.8 and 2.2±0.7; p> 0.05). Sensitivity (77% [17/22] vs. 82% [18/22] p>0.05) and specificity (72% [13/18] vs. 72% [13/18] p>0.05) for the detection of coronary artery stenosis also did not differ significantly between scans with and without intravenous administration of nitroglycerin. Conclusion: Administration of nitroglycerin does not improve visualization of the coronary arteries and

  13. Patient-specific coronary blood supply territories for quantitative perfusion analysis

    Science.gov (United States)

    Zakkaroff, Constantine; Biglands, John D.; Greenwood, John P.; Plein, Sven; Boyle, Roger D.; Radjenovic, Aleksandra; Magee, Derek R.

    2018-01-01

    Abstract Myocardial perfusion imaging, coupled with quantitative perfusion analysis, provides an important diagnostic tool for the identification of ischaemic heart disease caused by coronary stenoses. The accurate mapping between coronary anatomy and under-perfused areas of the myocardium is important for diagnosis and treatment. However, in the absence of the actual coronary anatomy during the reporting of perfusion images, areas of ischaemia are allocated to a coronary territory based on a population-derived 17-segment (American Heart Association) AHA model of coronary blood supply. This work presents a solution for the fusion of 2D Magnetic Resonance (MR) myocardial perfusion images and 3D MR angiography data with the aim to improve the detection of ischaemic heart disease. The key contribution of this work is a novel method for the mediated spatiotemporal registration of perfusion and angiography data and a novel method for the calculation of patient-specific coronary supply territories. The registration method uses 4D cardiac MR cine series spanning the complete cardiac cycle in order to overcome the under-constrained nature of non-rigid slice-to-volume perfusion-to-angiography registration. This is achieved by separating out the deformable registration problem and solving it through phase-to-phase registration of the cine series. The use of patient-specific blood supply territories in quantitative perfusion analysis (instead of the population-based model of coronary blood supply) has the potential of increasing the accuracy of perfusion analysis. Quantitative perfusion analysis diagnostic accuracy evaluation with patient-specific territories against the AHA model demonstrates the value of the mediated spatiotemporal registration in the context of ischaemic heart disease diagnosis. PMID:29392098

  14. Urinary bisphenol a concentration and angiography-defined coronary artery stenosis.

    Directory of Open Access Journals (Sweden)

    David Melzer

    Full Text Available Bisphenol A is widely used in food and drinks packaging. There is evidence of associations between raised urinary bisphenol A (uBPA and increased incidence of reported cardiovascular diagnoses.To estimate associations between BPA exposure and angiographically graded coronary atherosclerosis. 591 patients participating in The Metabonomics and Genomics in Coronary Artery Disease (MaGiCAD study in Cambridgeshire UK, comparing urinary BPA (uBPA with grades of severity of coronary artery disease (CAD on angiography. Linear models were adjusted for BMI, occupational social class and diabetes status. Severe (one to three vessel CAD was present in 385 patients, 86 had intermediate disease (n=86 and 120 had normal coronary arteries. The (unadjusted median uBPA concentration was 1.28 ng/mL with normal coronary arteries, and 1.53 ng/mL with severe CAD. Compared to those with normal coronary arteries, uBPA concentration was significantly higher in those with severe CAD (OR per uBPA SD=5.96 ng/ml OR=1.43, CI 1.03 to 1.98, p=0.033, and near significant for intermediate disease (OR=1.69, CI 0.98 to 2.94, p=0.061. There was no significant uBPA difference between patients with severe CAD (needing surgery and the remaining groups combined.BPA exposure was higher in those with severe coronary artery stenoses compared to those with no vessel disease. Larger studies are needed to estimate true dose response relationships. The mechanisms underlying the association remain to be established.

  15. Physiology of in vitro culture

    Directory of Open Access Journals (Sweden)

    Maria Jesús Cañal

    2001-01-01

    Full Text Available The culture procedures described up to the eighties, did not made any mention to the environmental control of in vitro plant development. However, growth rate, development and many of the physiologic-morphologic features of the in vitro grown plants are influenced by the culture vessel. The increasing knowledge about the environmental control of culture vessels under sterile conditions, is helping to change micorpropagation procedures. The in vitro environment with lower rate ventilation, brings about low flow rates of matter and energy, with minimum variations of temperature, high relative humidity and large daily changes of the concentration of CO2 inside the culture vessel. The type of culture vessel (size, shape, fabric and closing system can influence the evolution of the atmosphere along the time of culture. Although submitted to different stresses factors plant can be grown in vitro, but plants can be faulty in their anatomy, morphology and physiology. As a consequence, these plants shown a phenotype unable to survive to ex vitro conditions. Different strategies can be used to control the atmosphere along the different phases of micropropagation, in heterotrophic, mixotrophic or autotrophic cultures. The election of the best strategy will be based on different factors as species, number of transplantes required, or quality-price relationship. enviromental control, tissue culture, micropropagation Keywords: in vitro enviromental, characteristic physiology,

  16. Stress thallium-201 myocardial scintigraphy for the detection of individual coronary arterial lesions in patients with and without previous myocardial infarction

    International Nuclear Information System (INIS)

    Rigo, P.; Bailey, I.K.; Griffith, L.S.; Pitt, B.; Wagner, H.N. Jr.; Becker, L.C.

    1981-01-01

    The value of stress thallium-201 scintigraphy for detecting individual coronary arterial stenoses was analyzed in 141 patients with angiographically proved coronary artery disease, 101 with and 40 without a previous myocardial infarction. In patients without infarction, the sensitivity for detecting greater than 50 percent narrowing in the left anterior descending, the right and the left circumflex coronary artery was 66, 53 and 24 percent, respectively. In those with a previous infarction, the sensitivity for demonstrating disease in the artery corresponding to the site of infarction was 100 percent for the left anterior descending, 79 percent for the right and 63 percent for the left circumflex coronary artery. In patients with a prior anterior infarction, concomitant right or left circumflex coronary arterial lesions were detected in only 1 of 12 cases, whereas in those with previous inferior or inferolateral infarction, the sensitivity for left anterior descending coronary artery disease was 69 percent. Because of the reasonably high sensitivity for detecting left anterior descending arterial disease, irrespective of the presence and location of previous infarction, myocardial scintigraphy was useful in identifying multivessel disease in patients with a previous inferior infarction. However, because of its relative insensitivity for right or left circumflex coronary artery disease, scintigraphy proved to be a poor predictor of multivessel disease in patients with a prior anterior infarction and in patients without previous myocardial infarction

  17. A patient-specific virtual stenotic model of the coronary artery to analyze the relationship between fractional flow reserve and wall shear stress.

    Science.gov (United States)

    Lee, Kyung Eun; Kim, Gook Tae; Lee, Jeong Sang; Chung, Ju-Hyun; Shin, Eun-Seok; Shim, Eun Bo

    2016-11-01

    As the stenotic severity of a patient increases, fractional flow reserve (FFR) decreases, whereas the maximum wall shear stress (WSSmax) increases. However, the way in which these values can change according to stenotic severity has not previously been investigated. The aim of this study is to devise a virtual stenosis model to investigate variations in the coronary hemodynamic parameters of patients according to stenotic severity. To simulate coronary hemodynamics, a three-dimensional (3D) coronary artery model of computational fluid dynamics is coupled with a lumped parameter model of the coronary micro-vasculature and venous system. To validate the present method, we first simulated 13 patient-specific models of the coronary arteries and compared the results with those obtained clinically. Then, virtually narrowed coronary arterial models derived from the patient-specific cases were simulated to obtain the WSSmax and FFR values. The variations in FFR and WSSmax against the percentage of diameter stenosis in clinical cases were reproducible by the virtual stenosis models. We also found that the simulated FFR values were linearly correlated with the WSSmax values, but the linear slope varied by patient. We implemented 130 additional virtual models of stenosed coronary arteries based on data from 13 patients and obtained statistically meaningful results that were identical to the large-scale clinical studies. And the slope of the correlation line between FFR and WSSmax may help clinicians to design treatment plans for patients. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  18. Multislice CT coronary angiography: evaluation of an automatic vessel detection tool

    International Nuclear Information System (INIS)

    Dewey, M.; Schnapauff, D.; Lembcke, A.; Hamm, B.; Rogalla, P.; Laule, M.; Borges, A.C.; Rutsch, W.

    2004-01-01

    Purpose: To investigate the potential of a new detection tool for multisliceCT (MSCT) coronary angiography with automatic display of curved multiplanar reformations and orthogonal cross-sections. Materials and Methods: Thirty-five patients were consecutively enrolled in a prospective intention-to-diagnose study and examined using a MSCT scanner with 16 x 0.5 mm detector collimation and 400 ms gantry rotation time (Aquilion, Toshiba). A multisegment algorithm using up to four segments was applied for ECG-gated reconstruction. Automatic and manual detection of coronary arteries was conducted using the coronary artery CT protocol of a workstation (Vitrea 2, Version 3.3, Vital Images) to detect significant stenoses (≥50%) in all segments of ≥1.5 mm in diameter. Each detection tool was used by one reader who was blinded to the results of the other detection method and the results of conventional coronary angiography. Results: The overall sensitivity, specificity, nondiagnostic rate, and accuracy of the automatic and manual approach were 90 vs. 94%, 89 vs. 84%, 6 vs. 6%, and 89 vs. 88%, respectively (p=n.s.). The vessel length detected with the automatic and manual approach were highly correlated for the left main/left anterior descending (143±30 vs. 146±24 mm, r=0.923, p [de

  19. Comparison of exercise electrocardiography and quantitative thallium imaging for one-vessel coronary artery disease

    International Nuclear Information System (INIS)

    Kaul, S.; Kiess, M.; Liu, P.; Guiney, T.E.; Pohost, G.M.; Okada, R.D.; Boucher, C.A.

    1985-01-01

    The relative value of exercise electrocardiography and computer analyzed thallium-201 imaging was compared in 124 patients with 1-vessel coronary artery disease (CAD). Of these, 78 had left anterior descending (LAD), 32 right and 14 left circumflex (LC) CAD. In patients with no previous myocardial infarction (MI), thallium imaging was more sensitive than the electrocardiogram (78% vs 64%, p less than 0.01), but in patients with previous MI, sensitivity was similar. Further, thallium imaging was more sensitive only in LAD and LC disease. Redistribution was compared with ST-segment depression as a marker of ischemia. Only in patients with prior MI (76% vs 44%, p less than 0.01) and only in LC and right CAD did redistribution occur more often than ST depression. Thallium imaging was more accurate in localizing stenoses than the electrocardiogram (p less than 0.001), but did not always correctly predict coronary anatomy. Septal thallium defects were associated with LAD disease in 84%, inferior defects with right CAD in 40% and posterolateral lesion defects with LC CAD in 22%. The results indicate the overall superiority of thallium imaging in 1-vessel CAD compared with exercise electrocardiography; however, there is a wide spectrum of extent and location of perfusion defects associated with each coronary artery. Thallium imaging complements coronary angiography by demonstrating the functional impact of CAD on myocardial perfusion

  20. Radionuclide methods of identifying patients who may require coronary artery bypass surgery

    International Nuclear Information System (INIS)

    Beller, G.A.; Gibson, R.S.; Watson, D.D.

    1985-01-01

    Myocardial thallium-201 ( 201 Tl) scintigraphy or radionuclide angiography performed in conjunction with exercise stress testing can provide clinically useful information regarding the functional significance of underlying coronary artery stenoses in patients with known or suspected coronary artery disease. Knowledge of type, location, and extent of myocardial 201 Tl perfusion abnormalities or the severity of exercise-induced global and regional dysfunction has prognostic value. Risk stratification can be undertaken with either radionuclide technique by consideration of the magnitude of the ischemic response and may assist in the selection of patients for coronary artery bypass graft surgery (CABG). In patients with coronary artery disease, delayed 201 Tl redistribution observed on exercise or dipyridamole 201 Tl scintigraphy, particularly when present in multiple vascular regions and associated with increased lung 201 Tl uptake, has been shown to be predictive of an adverse outcome, whereas patients with chest pain and a normal exercise 201 Tl scintigram have a good prognosis with medical treatment. Similarly, a marked fall in the radionuclide ejection fraction from rest to exercise has been found to correlate with high-risk anatomic disease. Another important application of radionuclide imaging in patients being considered for CABG (particularly those with a depressed resting left ventricular ejection fraction) is the determination of myocardial viability and potential for improved blood flow and enhanced regional function after revascularization. 69 references

  1. Case Report of First Angiography-Based On-Line FFR Assessment during Coronary Catheterization.

    Science.gov (United States)

    Kornowski, Ran; Vaknin-Assa, Hana

    2017-01-01

    Fractional flow reserve (FFR), an index of the hemodynamic severity of coronary stenoses, is derived from hyperemic pressure measurements and requires a pressure-monitoring guide wire and hyperemic stimulus. Although it has become the standard of reference for decision-making regarding coronary revascularization, the procedure remains underutilized due to its invasive nature. FFR angio is a novel technology that uses the patient's hemodynamic data and routine angiograms to generate a complete three-dimensional coronary tree, with color-coded display of the FFR values at each point along the vessels. After being proven to be as accurate as invasive FFR measurements in an off-line study, this case report presents the first on-line application of the system in the catheterization lab. Here too, a high concordance between FFR angio and invasive FFR was observed. In light of the demonstrated capabilities of the FFR angio system, it should emerge as an important tool for clinical decision-making regarding revascularization in patients with coronary artery disease.

  2. Case Report of First Angiography-Based On-Line FFR Assessment during Coronary Catheterization

    Directory of Open Access Journals (Sweden)

    Ran Kornowski

    2017-01-01

    Full Text Available Fractional flow reserve (FFR, an index of the hemodynamic severity of coronary stenoses, is derived from hyperemic pressure measurements and requires a pressure-monitoring guide wire and hyperemic stimulus. Although it has become the standard of reference for decision-making regarding coronary revascularization, the procedure remains underutilized due to its invasive nature. FFRangio is a novel technology that uses the patient’s hemodynamic data and routine angiograms to generate a complete three-dimensional coronary tree, with color-coded display of the FFR values at each point along the vessels. After being proven to be as accurate as invasive FFR measurements in an off-line study, this case report presents the first on-line application of the system in the catheterization lab. Here too, a high concordance between FFRangio and invasive FFR was observed. In light of the demonstrated capabilities of the FFRangio system, it should emerge as an important tool for clinical decision-making regarding revascularization in patients with coronary artery disease.

  3. The value of 201Tl myocardial scintigraphy and of computed tomography for predicting the effectiveness of coronary artery bypass surgery

    International Nuclear Information System (INIS)

    Krosse, B.; Duck, H.J.; Neumann, G.; Huppert, P.; Schulz, H.G.; Lindenau, K.F.

    1986-01-01

    50 male patients with stenosing coronary artery sclerosis and an indication for coronary artery bypass surgery were subjected to pre- and postsurgical 201 Tl scintigraphy and postsurgical computed tomography. Control by angiography was carried out in six cases. Scintigraphy revealed an improved myocardial perfusion in 30 patients, whereas it was unchanged in 15 and deteriorated in 5 patients. Angiography exhibited two cases of graft occlusion, one case of bad run off, and two cases of progressing arteriosclerosis under intact graft. Computed tomography showed that 83 bypasses of the 50 patients were occluded in 6 cases, which was confirmed by angiography in 3 cases. The investigation demonstrates the high value of the two non-invasive methods for the control of bypass patency. (author)

  4. Myocardial scintigraphy with thallium-201 and technetium-99m-hexakis-methoxyisobutylisonitrile in left bundle branch block: a study in patients with and without coronary artery disease

    International Nuclear Information System (INIS)

    Knapp, W.H.; Bentrup, A.; Schmidt, U.; Ohlmeier, H.; Bochum Univ. Hospital, Bad Oeynhausen

    1993-01-01

    In left bundle branch block (LBBB) thallium-201 myocardial scintigraphy frequently reveals septal abnormalities in the absence of coronary artery disease (CAD) and gives rise to 'false-positive' results in patients with suspected CAD. It has not yet been clarified which pathophysiological mechanism is responsible for these perfusion abnormalities. A total of 66 patients with constant LBBB were investigated with 201 Tl or technetium-99m-hexakis-methoxyisobutylisonitrile (MIBI), 62 underwent coronary angiography. Of 12 patients without left anterior descending artery (LAD) or right coronary artery (RCA) stenoses, 11 had a reversible septal activity deficit after 201 Tl stress injection, whereas 20 of 22 patients without relevant CAD showed a constant stress/rest septal deficit using MIBI. Regarding patients with significant LAD and/or RCA stenoses, both radio-pharmaceuticals almost always showed a 'reversible' septal deficit: With 201 Tl in 15 of 16 individuals and with MIBI in 14 of 15. In 12 patients 201 Tl was reinjected at rest. In those who had LAD or RCA stenoses (n=5), early septal activity uptake after stress injection was poorer than that after rest injection; in the absence of CAD (n=7), septal stress uptake corresponded with that of rest injection. It is concluded that septal perfusion abnormalities in LBBB and the absence of CAD are characterized by an exercise-independent reduction of septal blood flow per mass of viable myocardium and that stress/rest injection protocols of myocardial perfusion tracers are able to differentiate between LBBB with and without CAD. (orig.)

  5. The In vitro meat cookbook

    NARCIS (Netherlands)

    Mensvoort, van K.M.; Grievink, H.J.

    2014-01-01

    With the world's population expected to reach nine billion people by 2050, it becomes impossible to produce and consume meat like we do today. In vitro meat, grown from cells in a laboratory, could provide a sustainable and animal-friendly alternative. Yet, before we can decide if we are willing to

  6. Synthetic biology projects in vitro.

    Science.gov (United States)

    Forster, Anthony C; Church, George M

    2007-01-01

    Advances in the in vitro synthesis and evolution of DNA, RNA, and polypeptides are accelerating the construction of biopolymers, pathways, and organisms with novel functions. Known functions are being integrated and debugged with the aim of synthesizing life-like systems. The goals are knowledge, tools, smart materials, and therapies.

  7. Coronary artery aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Koischwitz, D.; Harder, T.; Schuppan, U.; Thurn, P.

    1982-04-01

    Seven saccular coronary artery aneurysms have been demonstrated in the course of 1452 selective coronary artery angiograms. In six patients they were arterio-sclerotic; in one patient the aneurysm must have been congenital or of mycotic-embolic origin. The differential diagnosis between true aneurysms and other causes of vascular dilatation is discussed. Coronary artery aneurysms have a poor prognosis because of the possibility of rupture with resultant cardiac tamponade, or the development of thrombo-embolic myocardial infarction. These aneurysms can only be diagnosed by means of coronary angiography and require appropriate treatment.

  8. Indications for coronary angiography

    International Nuclear Information System (INIS)

    Kaltenbach, M.; Vallbracht, C.

    1985-01-01

    Today selective coronary angiography, introduced by Sones in 1957, is used as clinical routine for diagnosing morphological changes in the coronary arteries. Hitherto, more recent techniques such as digital subtraction angiography cannot provide comparable information. Strict criteria for its indication depending on possible therapeutic consequences, have to be applied, although the risk is low with a letality of 0.01 to 0.05 percent. Radionuclear investigations can be used as additional tool in selected cases. The careful indication for coronary angiography usually implies the possible need for coronary bypass graft surgery of balloon angioplasty. (orig./MG) [de

  9. Percutaneous therapy of inoperable biliary stenoses and occlusions with a new self-expanding nitinol stent (SMART)

    International Nuclear Information System (INIS)

    Zorger, N.; Lenhart, M.; Strotzer, M.; Paetzel, C.; Hamer, O.; Feuerbach, S.; Link, J.

    2002-01-01

    Objective: To evaluate the treatment of malignant biliary stenoses and occlusions using a new stent. Methods: In a prospective study, 25 patients with malignant obstructive jaundice were treated with SMART stents. The handling and the quality of stent expansion were documented. Stent function was assessed 2-4 days after intervention by cholangiography and laboratory tests. A follow-up was performed three months, after stent placement. Results: All lesions were treated successfully, with a total of 35 stents implanted. In 14 patients a further balloon dilatation was performed after stent placement (8-10 mm diameter/40-80 mm length). The mean serum bilirubin level decreased significantly from 11.6 mg/dl to 4.6 mg/dl after intervention (p [de

  10. Variable-viscosity thermal hemodynamic slip flow conveying nanoparticles through a permeable-walled composite stenosed artery

    Science.gov (United States)

    Akbar, Noreen Sher; Tripathi, Dharmendra; Bég, O. Anwar

    2017-07-01

    This paper presents a mathematical model for simulating viscous, incompressible, steady-state blood flow containing copper nanoparticles and coupled heat transfer through a composite stenosed artery with permeable walls. Wall slip hydrodynamic and also thermal buoyancy effects are included. The artery is simulated as an isotropic elastic tube, following Joshi et al. (2009), and a variable viscosity formulation is employed for the flowing blood. The equations governing the transport phenomena are non-dimensionalized and the resulting boundary value problem is solved analytically in the steady state subject to physically appropriate boundary conditions. Numerical computations are conducted to quantify the effects of relevant hemodynamic, thermophysical and nanoscale parameters emerging in the model on velocity and temperature profiles, wall shear stress, impedance resistance and also streamline distributions. The model may be applicable to drug fate transport modeling with nanoparticle agents and also to the optimized design of nanoscale medical devices for diagnosing stenotic diseases in circulatory systems.

  11. 3-D flow characterization and shear stress in a stenosed carotid artery bifurcation model using stereoscopic PIV technique.

    Science.gov (United States)

    Kefayati, Sarah; Poepping, Tamie L

    2010-01-01

    The carotid artery bifurcation is a common site of atherosclerosis which is a major leading cause of ischemic stroke. The impact of stenosis in the atherosclerotic carotid artery is to disturb the flow pattern and produce regions with high shear rate, turbulence, and recirculation, which are key hemodynamic factors associated with plaque rupture, clot formation, and embolism. In order to characterize the disturbed flow in the stenosed carotid artery, stereoscopic PIV measurements were performed in a transparent model with 50% stenosis under pulsatile flow conditions. Simulated ECG gating of the flowrate waveform provides external triggering required for volumetric reconstruction of the complex flow patterns. Based on the three-component velocity data in the lumen region, volumetric shear-stress patterns were derived.

  12. Requirements of exercise myocardial scintigraphy (EMS) using Tl-201 prior and subsequent to coronary revascularisation, based on the example of transluminal angioplasty

    International Nuclear Information System (INIS)

    Maul, F.D.; Hoer, G.; Standke, R.; Kober, G.; Klepzig, H. Jr.; Doerr, G.; Baum, R.P.; Happ, J.; Kaltenbach, M.; Frankfurt Univ.

    1985-01-01

    Quantitative exercise myocardial scintigraphy (EMS) using Thallium-201 in planar technique was applied in 128 patients prior and subsequent to transluminal coronary angioplasty. The overall sensitivity was 92%, and 88% for multivessel disease. In contrast to previous reports, the sensitivity for lesions of the posterior wall proved not inferior to that for lesions of the anterior wall: RCA-stenoses 92%; LCX-stenoses 100% and RIA-stenoses 93%. The specificity was found to be 88%, and the accuracy 92%. Myocardial ischaemia, as detected by EMS and ex. ECG, amounted to 84% and 72%, respectively in single vessel disease. The degree of ischaemia, which was measured semiquantitatively in terms of score, paralleled that of stenosis. The accuracy for localisation of anterior or posterior wall lesions was 92%. In unsuccessfully treated patients the results were completely reproducible (100%) both in terms of the decision 'CAD yes or no', and regarding the localisation of a myocardial lesion. The reproducibility for detection of myocardial ischaemia was 82%. Conclusion: In comparison with SPECT the quantitative planar EMS procedure using Tl-201 is the method of choice for the detection and assessment of ischaemia prior and subsequent to revascularisation therapy. (orig.) [de

  13. Symptomatic coronary artery disease after mantle irradiation for Hodgkin's disease

    International Nuclear Information System (INIS)

    King, Vernon; Constine, Louis S.; Clark, Douglas; Schwartz, Ronald G.; Muhs, Ann G.; Henzler, Margaret; Hutson, Alan; Rubin, Philip

    1996-01-01

    least one major vessel in 11 patients (73%), and no single artery was more commonly stenosed. Specifically, the left anterior descending and right coronary arteries were each greater than or equal to 60% stenosed in 10 out of 15 patients (67%), and either the left main or circumflex arteries were greater than or equal to 50% stenosed in 5 out of 15 patients (33%); triple vessel disease was present in seven patients. Risk factor data were available on all patients experiencing morbid cardiac events: 72% smoked, 72% were male, 78% had hypercholesterolemia, 61% were obese, 28% had a positive family history, 33% had hypertension, and 6% (one) had diabetes. The average number of risk factors per patient was 2.9; seven patients had at least four risk factors, and all patients had at least one risk factor. This frequency of risk factors is elevated when compared to the US population. Conclusions: In our institution, 5.5% of patients treated for Hodgkin's disease experienced a morbid cardiac event following RT to the central cardiac volume. The doses given were greater than commonly used today. Some patients experienced events at a young age, and the likelihood of experiencing CD was increased compared to the general population. This observation is consistent with RT as an additional risk factor in the induction of morbid cardiac events. Appropriate cardiac shielding and radiation doses, careful follow-up, which includes monitoring of cardiac function, and a preventative program of sensible dietary habits, exercise, and nonsmoking may be beneficial in reducing cardiac morbidity in long-term survivors of Hodgkin's disease

  14. Natural History of Moderate Coronary Artery Stenosis After Surgical Revascularization.

    Science.gov (United States)

    Raza, Sajjad; Blackstone, Eugene H; Houghtaling, Penny L; Olivares, Gabriel; Ravichandren, Kirthi; Koprivanac, Marijan; Bakaeen, Faisal G; Sabik, Joseph F

    2018-03-01

    It remains controversial whether grafting moderately stenosed coronary arteries (MSCAs) influences native-vessel disease progression and whether grafting may protect against late myocardial ischemia. From 1972 to 2011, 55,567 patients underwent primary isolated coronary artery bypass grafting (CABG); 1,902 had a single coronary artery with angiographically moderate (50% to 69%) stenosis and ≥1 postoperative angiogram. Disease progression was studied in 489 nongrafted, 371 internal thoracic artery (ITA)-grafted, and 957 saphenous vein (SV)-grafted MSCAs, as well as patency of 376 ITA and 1,016 SV grafts to these MSCAs. At 1, 5, 10, and 15 years, native-vessel disease progressed from moderate to severe stenosis/occlusion in 32%, 52%, 66%, and 72% of nongrafted MSCAs; 55%, 73%, 84%, and 87% of ITA-grafted MSCAs; and 67%, 82%, 90%, and 92% of SV-grafted MSCAs. After adjusting for patient characteristics, MSCA disease progressed 3.6 times faster with ITA and 10 times faster with SV grafting compared with nongrafting. At these same time points, occlusion of ITA grafts to MSCAs was 8%, 9%, 11%, and 15% and for SV grafts, 13%, 32%, 46%, and 56%; protection from myocardial ischemia by ITA-grafted versus nongrafted MSCAs was 29%, 47%, 59%, and 61%. Most MSCAs progress to severe stenosis or occlusion in the long term. Progression is faster in grafted than nongrafted MSCAs, more so with SV than ITA grafts. However, ITA grafts to such arteries have excellent patency, providing long-term protection from myocardial ischemia. Therefore, ITA grafting of MSCAs should be considered. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Numerical analysis of the effect of turbulence transition on the hemodynamic parameters in human coronary arteries.

    Science.gov (United States)

    Mahalingam, Arun; Gawandalkar, Udhav Ulhas; Kini, Girish; Buradi, Abdulrajak; Araki, Tadashi; Ikeda, Nobutaka; Nicolaides, Andrew; Laird, John R; Saba, Luca; Suri, Jasjit S

    2016-06-01

    Local hemodynamics plays an important role in atherogenesis and the progression of coronary atherosclerosis disease (CAD). The primary biological effect due to blood turbulence is the change in wall shear stress (WSS) on the endothelial cell membrane, while the local oscillatory nature of the blood flow affects the physiological changes in the coronary artery. In coronary arteries, the blood flow Reynolds number ranges from few tens to several hundreds and hence it is generally assumed to be laminar while calculating the WSS calculations. However, the pulsatile blood flow through coronary arteries under stenotic condition could result in transition from laminar to turbulent flow condition. In the present work, the onset of turbulent transition during pulsatile flow through coronary arteries for varying degree of stenosis (i.e., 0%, 30%, 50% and 70%) is quantitatively analyzed by calculating the turbulent parameters distal to the stenosis. Also, the effect of turbulence transition on hemodynamic parameters such as WSS and oscillatory shear index (OSI) for varying degree of stenosis is quantified. The validated transitional shear stress transport (SST) k-ω model used in the present investigation is the best suited Reynolds averaged Navier-Stokes turbulence model to capture the turbulent transition. The arterial wall is assumed to be rigid and the dynamic curvature effect due to myocardial contraction on the blood flow has been neglected. Our observations shows that for stenosis 50% and above, the WSSavg, WSSmax and OSI calculated using turbulence model deviates from laminar by more than 10% and the flow disturbances seems to significantly increase only after 70% stenosis. Our model shows reliability and completely validated. Blood flow through stenosed coronary arteries seems to be turbulent in nature for area stenosis above 70% and the transition to turbulent flow begins from 50% stenosis.

  16. Diagnostic Value of 64-Slice Dual-Source CT Coronary Angiography in Patients with Atrial Fibrillation: Comparison with Invasive Coronary Angiography

    International Nuclear Information System (INIS)

    Zhang, Jian Jun; Liu, Tie; Feng, Yue; Wu, Wei Feng; Mou, Cai Yun; Zhai, Li Hao

    2011-01-01

    We wanted to evaluate the image quality and diagnostic value of 64-slice dual-source computed tomography (DSCT) coronary angiography in patients with atrial fibrillation (Afib). The coronary arteries of 22 Afib patients seen on DSCT were classified into 15 segments and the imaging quality (excellent, good, moderate and poor) and significant stenoses (≥ 50%) were evaluated by two radiologists who were blinded to the conventional coronary angiography (CAG) results. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for detecting important coronary artery stenosis were calculated. McNemar test was used to determine any significant difference between DSCT and CAG, and Cohen's Kappa statistics were calculated for the intermodality and interobserver agreement. The mean heart rate was 89 ± 8.3 bpm (range: 80-118 bpm). A range from 250 msec to 300 msec within the RR interval was the optimal reconstruction interval for the patients with Afib. The respective overall sensitivity, specificity, PPV and NPV values were 74%, 97%, 81% and 96% for reader 1 and 72%, 98%, 85% and 96% for reader 2. No significant difference between DSCT and CAG was found for detecting a significant stenosis (reader 1, p = 1.0; reader 2, p = 0.727). Cohen's Kappa statistics demonstrated good intermodality and interobserver agreement. 64-slice DSCT coronary angiography provides good image quality in patients with atrial fibrillation without the need for controlling the heart rate. DSCT can be used for ruling out significant stenosis in patients with atrial fibrillation with its high NPV for detecting in important stenosis.

  17. Diagnostic Value of 64-Slice Dual-Source CT Coronary Angiography in Patients with Atrial Fibrillation: Comparison with Invasive Coronary Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jian Jun; Liu, Tie; Feng, Yue; Wu, Wei Feng; Mou, Cai Yun; Zhai, Li Hao [Zhejiang Hospital, Hangzhou (China)

    2011-08-15

    We wanted to evaluate the image quality and diagnostic value of 64-slice dual-source computed tomography (DSCT) coronary angiography in patients with atrial fibrillation (Afib). The coronary arteries of 22 Afib patients seen on DSCT were classified into 15 segments and the imaging quality (excellent, good, moderate and poor) and significant stenoses ({>=} 50%) were evaluated by two radiologists who were blinded to the conventional coronary angiography (CAG) results. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for detecting important coronary artery stenosis were calculated. McNemar test was used to determine any significant difference between DSCT and CAG, and Cohen's Kappa statistics were calculated for the intermodality and interobserver agreement. The mean heart rate was 89 {+-} 8.3 bpm (range: 80-118 bpm). A range from 250 msec to 300 msec within the RR interval was the optimal reconstruction interval for the patients with Afib. The respective overall sensitivity, specificity, PPV and NPV values were 74%, 97%, 81% and 96% for reader 1 and 72%, 98%, 85% and 96% for reader 2. No significant difference between DSCT and CAG was found for detecting a significant stenosis (reader 1, p = 1.0; reader 2, p = 0.727). Cohen's Kappa statistics demonstrated good intermodality and interobserver agreement. 64-slice DSCT coronary angiography provides good image quality in patients with atrial fibrillation without the need for controlling the heart rate. DSCT can be used for ruling out significant stenosis in patients with atrial fibrillation with its high NPV for detecting in important stenosis.

  18. Comparison of sensitizers in vitro

    International Nuclear Information System (INIS)

    Hall, E.J.; Astor, M.

    1980-01-01

    Clinical trials of misonidazole are already well underway, but no definitive conclusions are likely for several years. Meanwhile, attention in the laboratory is directed toward identifying or synthesizing alternative compounds, which equal misonidazole in radiosensitizing efficiency, while at the same time exhibiting less troublesome side effects. Two of the most promising contenders are desmethylmisonidazole and SR 2508. The present communication describes experiments with cells cultured in vitro designed to compare the properties of misonidazole with these two potential replacements

  19. Large coronary intramural hematomas

    DEFF Research Database (Denmark)

    Antonsen, Lisbeth; Thayssen, Per; Jensen, Lisette Okkels

    2015-01-01

    Isolated spontaneous coronary intramural hematoma is a unique subset of spontaneous coronary artery dissection that is characterized by a hemorrhage limited to the medial-adventitial layers, causing subsequent hematoma formation without visible intimal flaps. It is an infrequent and serious...... diagnostics and treatment strategy. Coronary intramural hematomas can also occur iatrogenically, as a complication to percutaneous coronary intervention (PCI). Coronary angiography (CAG) has limited diagnostic value in the absence of intimal dissections, and lesions are often angiographically ambiguous....... Intravascular ultrasound (IVUS) is an important diagnostic tool in establishing the correct diagnosis, as it provides a complete vessel wall assessment, and enables morphometric information regarding the magnitude and severity of the underlying hematoma. Due to the rarity of this clinical scenario...

  20. New stent design for use in small coronary arteries during percutaneous coronary intervention

    Directory of Open Access Journals (Sweden)

    Juan F Granada

    2010-10-01

    Full Text Available Juan F Granada1, Barbara A Huibregtse2, Keith D Dawkins21The Jack H Skirball Center for Cardiovascular Research, Cardiovascular Research Foundation, Columbia University Medical Center, New York, NY, USA; 2Boston Scientific Corporation, Natick, MA, USAAbstract: Patients with diabetes mellitus, of female gender, increased age, and/or with peripheral vascular disease often develop coronary stenoses in small caliber vessels. This review describes treatment of these lesions with the paclitaxel-eluting 2.25 mm TAXUS® Liberté® Atom™ stent. Given the same stent composition, polymer, antirestenotic drug (paclitaxel, and release kinetics as the first-generation 2.25 mm TAXUS® Express® Atom™ stent, the second-generation TAXUS Liberté Atom stent incorporates improved stent design characteristics, including thinner struts (0.0038 versus 0.0052 inches, intended to increase conformability and deliverability. In a porcine noninjured coronary artery model, TAXUS Liberté Atom stent implantation in small vessels demonstrated complete strut tissue coverage compared with the bare metal stent control, suggesting a similar degree of tissue healing between the groups at 30, 90, and 180 days. The prospective, single-armed TAXUS ATLAS Small Vessel trial demonstrated improved instent late loss (0.28 ± 0.45 versus 0.84 ± 0.57 mm, P < 0.001, instent binary restenosis (13.0% versus 38.1%, P < 0.001, and target lesion revascularization (5.8% versus 17.6%, P < 0.001 at nine months with the TAXUS Liberté Atom stent as compared with the bare metal Express stent control, with similar safety measures between the two groups. The TAXUS Liberté Atom also significantly reduced nine-month angiographic rates of both instent late loss (0.28 ± 0.45 versus 0.44 ± 0.61 mm, P = 0.03 and instent binary restenosis (13.0% versus 25.9%, P = 0.02 when compared with the 2.25 mm TAXUS Express Atom control. The observed reduction in target lesion revascularization with the TAXUS

  1. In vitro replication of poliovirus

    International Nuclear Information System (INIS)

    Lubinski, J.M.

    1986-01-01

    Poliovirus is a member of the Picornaviridae whose genome is a single stranded RNA molecule of positive polarity surrounded by a proteinaceous capsid. Replication of poliovirus occurs via negative strand intermediates in infected cells using a virally encoded RNA-dependent RNA polymerase and host cell proteins. The authors have exploited the fact that complete cDNA copies of the viral genome when transfected onto susceptible cells generate virus. Utilizing the bacteriophage SP6 DNA dependent RNA polymerase system to synthesize negative strands in vitro and using these in an in vitro reaction the authors have generated full length infectious plus strands. Mutagenesis of the 5' and 3' ends of the negative and positive strands demonstrated that replication could occur either de novo or be extensions of the templates from their 3' ends or from nicks occurring during replication. The appearance of dimeric RNA molecules generated in these reactions was not dependent upon the same protein required for de novo initiation. Full length dimeric RNA molecules using a 5' 32 P end-labelled oligo uridylic acid primer and positive strand template were demonstrated in vitro containing only the 35,000 Mr host protein and the viral RNA-dependent RNA polymerase. A model for generating positive strands without protein priming by cleavage of dimeric RNA molecules was proposed

  2. Feasibility of MR-guided angioplasty of femoral artery stenoses using real-time imaging and intraarterial contrast-enhanced MR angiography

    International Nuclear Information System (INIS)

    Paetzel, C.; Zorger, N.; Bachthaler, M.; Voelk, M.; Seitz, J.; Herold, T.; Feuerbach, S.; Lenhart, M.; Nitz, W.R.

    2004-01-01

    Purpose: To show the feasibility of magnetic resonance (MR) for guided interventional therapy of femoral and popliteal artery stenoses with commercially available materials supported by MR real-time imaging and intraarterial MR angiography. Materials and Methods: Three patients (1 female, 2 male), suffering from symptomatic arterial occlusive disease with stenoses of the femoral (n=2) or popliteal (n=1) arteries were included. Intraarterial digital subtraction angiography was performed in each patient pre- and post-interventionally as standard of reference to quantify stenoses. The degree of the stenoses reached from 71-88%. The MR images were acquired on a 1.5 T MR scanner (Magnetom Sonata; Siemens, Erlangen, Germany). For MR-angiography, a Flash 3D sequence was utilized following injection of 5 mL diluted gadodiamide (Omniscan; Amersham Buchler, Braunschweig, Germany) via the arterial access. Two maximum intensity projections (MIP) were used as road maps and localizer for the interactive positioning of a continuously running 2D-FLASH sequence with a temporal solution of 2 images per second. During the intervention, an MR compatible monitor provided the image display inside the scanner room. Safety guidelines were followed during imaging in the presence of a conductive guidewire. The lesion was crossed by a commercially available balloon catheter (Wanda, Boston Scientific; Ratingen, Germany), which was mounted on a 0.035'' guidewire (Terumo; Leuven, Belgium). The visibility was provided by radiopaque markers embedded in the balloon and was improved by injection of 1 mL gadodiamide into the balloon. After dilation, the result was checked by intraarterial MR angiography and catheter angiography. Results: The stenoses could be correctly localized by intraarterial MR angiography. There was complete correlation between intraarterial MR angiography and digital subtraction angiography. The combination of guidewire and balloon was visible and the balloon was placed

  3. [Endarterectomy of the coronary arteries].

    Science.gov (United States)

    Fischer, V; Simkovic, I; Holoman, M; Verchvodko, P; Janotík, P; Galbánek, J; Hulman, M; Kostelnicák, J; Jurco, R; Slezák, J

    1992-02-01

    The authors analyze 50 patients with endarterectomy of the coronary arteries during the periods of 1972-1974 and 1988-1990. The results of endarterectomy of the right and left coronary artery provide evidence of its justification in indicated cases whereby contrary to some departments the results of endarterectomy of the left coronary artery are comparable with endarterectomy of the right coronary artery.

  4. The harmonized INFOGEST in vitro digestion method

    NARCIS (Netherlands)

    Egger, Lotti; Ménard, Olivia; Delgado-Andrade, Cristina; Alvito, Paula; Assunção, Ricardo; Balance, Simon; Barberá, Reyes; Brodkorb, Andre; Cattenoz, Thomas; Clemente, Alfonso; Comi, Irene; Dupont, Didier; Garcia-Llatas, Guadalupe; Lagarda, María Jesús; Feunteun, Le Steven; Janssen Duijghuijsen, Lonneke; Karakaya, Sibel; Lesmes, Uri; Mackie, Alan R.; Martins, Carla; Meynier, Anne; Miralles, Beatriz; Murray, B.S.; Pihlanto, Anne; Picariello, Gianluca; Santos, C.N.; Simsek, Sebnem; Recio, Isidra; Rigby, Neil; Rioux, Laurie Eve; Stoffers, Helena; Tavares, Ana; Tavares, Lucelia; Turgeon, Sylvie; Ulleberg, E.K.; Vegarud, G.E.; Vergères, Guy; Portmann, Reto

    2016-01-01

    Within the active field of in vitro digestion in food research, the COST Action INFOGEST aimed to harmonize in vitro protocols simulating human digestion on the basis of physiologically inferred conditions. A harmonized static in vitro digestion (IVD) method was recently published as a primary

  5. Selective coronary scintigraphy

    International Nuclear Information System (INIS)

    Gambini, D.-J.

    1975-01-01

    Isotopic techniques occupy a leading place amongst examinations practicable on coronary patients because of their reliability and the safety and simplicity of their use. The present work reviews the possible applications of selective coronary scintigraphy in pathology. After a brief discussion on scintigraphy, isotopic techniques for myocardium research, coronarography and other methods to study local myocardium perfusion the theoretical bases for the use of the exploration are studied, the techniques and methods employed are reported and the results discussed. Coronary scintigraphy consists of selective injection in the two coronary arteries previously catheterized during a coronarography, of two different populations of microspheres labelled with two physically short-lived indicators: 15μ 99m Tc-labelled serumalbumin microspheres, 10 to 15μ In-labelled siderophiline microspheres. Various studies have shown the complete harmlessness of the exploration when certain precautions are taken regarding the size and number of the spheres. The microspheres disperse into the downstream arterial territory proportionally to the number of capillaries present in the different parts of the irrigated region, and are temporarily stopped in the precapillaries. The preparation of the different images needed to interpret the Face and OAG examination for the left coronary, then for the right coronary, is carried out at the end of the coronarography and lasts about 45 minutes. It is also possible by selective injection in the aorta-coronary bridges to judge their functional condition by observation of the regions they irrigate. 56 patients of the Necker hospital cardiological clinic have been examined [fr

  6. Congenital coronary artery fistula

    International Nuclear Information System (INIS)

    Oh, Yeon Hee; Kim, Hong; Zeon, Seoc Kil; Suh, Soo Jhi

    1986-01-01

    Congenital coronary artery fistula (CCAF) is communication of a coronary artery or its main branch with one of the atria or ventricles, the coronary sinus, the superior vena cava, or the pulmonary artery. In Korean peoples, only 4 cases of the CCAF were reported as rare as worldwide and authors want to report another case of CCAF, confirmed by operation. 10-year-old girl shows a fistula between sinus node artery of the right coronary artery and right atrium on root aortogram with left-to-right shunt and Qp/Qs=1.58, in which simple ligation of the sinus node artery from right coronary artery was performed. All of the 5 Korean CCAF (4 were previously reported and 1 of authors) were originated from right coronary artery, and of which 4 were opening into right ventricle and 1 of authors were into right atrium. Associated cardiac anomaly was noted in only 1 case as single coronary artery. Ages were from 9 months of age to 10 years old and no adult left case were found. 3 were female and 2 were male patients.

  7. Prevalence and severity of coronary artery disease in diabetic patients with aortic valve calcification.

    Science.gov (United States)

    Chen, Zhang-wei; Qian, Ju-ying; Jian, Ying; Ge, Lei; Liu, Xue-bo; Shu, Xian-hong; Ge, Junbo

    2011-02-01

    Aortic valve calcification (AVC) is common in the elderly and associated with increased cardiovascular mortality, while diabetes is one of the confirmed risk factors for coronary artery disease (CAD). In this study, we aimed to evaluate the prevalence and severity of CAD in type-2 diabetic patients with AVC. From June to December in 2007, a total of 325 consecutive patients with chest pain or chest distress were admitted for coronary angiography. The severity of CAD was evaluated by the Gensini score and the number of stenosed vessels. All patients underwent transthoracic echocardiography for detecting AVC. Compared with the patients without diabetes (n = 221), the type-2 diabetic patients (n = 104) had a similar prevalence of CAD (66.5% vs. 72.1%, P = 0.312). Further classified by the presence of AVC, patients with AVC had a higher prevalence of CAD, average Gensini score and the number of stenosed vessels, both in the group with and without diabetes. It was also demonstrated that the odds ratio (OR) of AVC for CAD in the diabetic patients was higher than in the non-diabetic ones (3.405 vs 2.515) after chi-square analysis (single-variable). However, at multivariable logistic regression analysis for CAD, the OR of AVC was 3.757 (P = 0.03) in diabetic group, while it did not achieve statistical significance in the non-diabetic group (OR = 2.130, P= 0.074). Type-2 diabetic patients with AVC had a higher prevalence of and more severe CAD.

  8. Non-cardiac findings on coronary computed tomography and magnetic resonance imaging

    International Nuclear Information System (INIS)

    Dewey, Marc; Schnapauff, Dirk; Teige, Florian; Hamm, Bernd

    2007-01-01

    Both multislice computed tomography (CT) and magnetic resonance imaging (MRI) are emerging as methods to detect coronary artery stenoses and assess cardiac function and morphology. Non-cardiac structures are also amenable to assessment by these non-invasive tests. We investigated the rate of significant and insignificant non-cardiac findings using CT and MRI. A total of 108 consecutive patients suspected of having coronary artery disease and without contraindications to CT and MRI were included in this study. Significant non-cardiac findings were defined as findings that required additional clinical or radiological follow-up. CT and MR images were read independently in a blinded fashion. CT yielded five significant non-cardiac findings in five patients (5%). These included a pulmonary embolism, large pleural effusions, sarcoid, a large hiatal hernia, and a pulmonary nodule (>1.0 cm). Two of these significant non-cardiac findings were also seen on MRI (pleural effusions and sarcoid, 2%). Insignificant non-cardiac findings were more frequent than significant findings on both CT (n = 11, 10%) and MRI (n = 7, 6%). Incidental non-cardiac findings on CT and MRI of the coronary arteries are common, which is why images should be analyzed by radiologists to ensure that important findings are not missed and unnecessary follow-up examinations are avoided. (orig.)

  9. Non-cardiac findings on coronary computed tomography and magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Dewey, Marc; Schnapauff, Dirk; Teige, Florian; Hamm, Bernd [Charite-Universitaetsmedizin Berlin, Humboldt-Universitaet zu Berlin, Department of Radiology, Chariteplatz 1, P.O. Box 10098, Berlin (Germany)

    2007-08-15

    Both multislice computed tomography (CT) and magnetic resonance imaging (MRI) are emerging as methods to detect coronary artery stenoses and assess cardiac function and morphology. Non-cardiac structures are also amenable to assessment by these non-invasive tests. We investigated the rate of significant and insignificant non-cardiac findings using CT and MRI. A total of 108 consecutive patients suspected of having coronary artery disease and without contraindications to CT and MRI were included in this study. Significant non-cardiac findings were defined as findings that required additional clinical or radiological follow-up. CT and MR images were read independently in a blinded fashion. CT yielded five significant non-cardiac findings in five patients (5%). These included a pulmonary embolism, large pleural effusions, sarcoid, a large hiatal hernia, and a pulmonary nodule (>1.0 cm). Two of these significant non-cardiac findings were also seen on MRI (pleural effusions and sarcoid, 2%). Insignificant non-cardiac findings were more frequent than significant findings on both CT (n = 11, 10%) and MRI (n = 7, 6%). Incidental non-cardiac findings on CT and MRI of the coronary arteries are common, which is why images should be analyzed by radiologists to ensure that important findings are not missed and unnecessary follow-up examinations are avoided. (orig.)

  10. Impact of glucose intolerance on coronary calcified lesions evaluated using multislice computed tomography

    International Nuclear Information System (INIS)

    Nomura, Kyoko; Ohwaki, Kazuhiro; Yano, Eiji; Yamanouchi, Toshikazu; Kim, Gwang U.

    2007-01-01

    Metabolic syndrome has the unique concept that the common occurrence of individual disease components increases the risk of coronary artery disease (CAD). However, some studies suggest that the burden of different CAD risk factors is not equal, and focusing on the whole set of risk factors might neglect the impact of individual factors that could be useful targets for prophylactic therapies. The purpose of this study was to investigate the effect of glucose intolerance on CAD using multislice computed tomography (MSCT). Ninety-eight consecutive patients with at least one traditional CAD risk factor who visited a municipal hospital were enrolled in this study. The risk factors were impaired glucose tolerance (fasting glucose≥110 mg/dl or patients with diabetes), low high-density lipoprotein cholesterol (HDL-C, 25 kg/m 2 for men and >23 kg/m 2 for women). CAD was determined by the presence of either stenoses, non-calcified plaques or calcified lesions. The following risk factors were significantly related in univariate logistic models: glucose intolerance and coronary calcified lesions (p=0.001), and hypertriglycemia and non-calcified plaque lesions (p=0.048). Multivariate models showed that glucose intolerance was significantly associated with calcified lesions, even after adjustment for gender, age, low HDL-C, hypertriglycemia, hypertension, and obesity (p=0.018). Our results suggest that glucose intolerance might be closely related to the presence of coronary calcified lesions among traditional CAD risk factors. (author)

  11. Automatic detection of coronary arterial branches from X-ray angiograms

    International Nuclear Information System (INIS)

    Lu, Shan; Eiho, Shigeru

    1992-01-01

    This paper describes a method to trace the coronary arterial boundaries automatically from x-ray angiograms. We developed an automatic procedure to detect the edges of an artery with its branches. The edge point is evaluated by a function based on smoothing differential operator on a searching line which is obtained by using the continuous properties of the arterial edges. Thus the boundary points along the artery are detected automatically. If there exists a branch on the boundary, it can be detected automatically. This information about the branch is stored on the stack of the search information and will be used to detect the branch artery. In our edge detection process, the required user interaction is only the manual definition of a starting point for the search, the direction of the search and the range for search. We tested this method on some images generated by a computer with different stenoses and on a coronary angiogram. These results show that this method is useful for analyzing coronary angiograms. (author)

  12. Coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Dewey, Marc [Charite - Universitaetsmedizin Berlin (Germany). Inst. fuer Radiologie

    2009-07-01

    Coronary CT angiography has attained increasing scientific attention at academic institutions and has become a highly accurate diagnostic modality. Extending this knowledge into a practice setting is the purpose of 'Coronary CT Angiography'. This book will assist you in integrating cardiac CT into your daily practice, while also giving an overview of the current technical status and applications. The specific features of scanners from all four main vendors are also presented providing an objective overview of noninvasive coronary angiography using CT. (orig.)

  13. Relationship between coronary flow reserve evaluated by phase-contrast cine cardiovascular magnetic resonance and serum eicosapentaenoic acid

    Science.gov (United States)

    2013-01-01

    Background Long-term intake of long-chain n-3 polyunsaturated fatty acids (n-3 PUFAs), especially eicosapentaenoic acid (EPA) is associated with a low risk for cardiovascular disease. Phase-contrast cine cardiovascular magnetic resonance (PC cine CMR) can assess coronary flow reserve (CFR). The present study investigates the relationship between CFR evaluated by PC cine CMR and the serum EPA. Methods We studied 127 patients (male, 116 (91%); mean age, 72.2 ± 7.4 years) with known or suspected coronary artery disease (CAD). X-ray coronary angiography revealed no significant coronary arterial stenoses (defined as luminal diameter reduction ≥50% on quantitative coronary angiogram (QCA) analysis) in all study participants. Breath-hold PC cine CMR images of the coronary sinus (CS) were acquired to assess blood flow of the CS both at rest and during adenosine triphosphate (ATP) infusion. We calculated CFR as CS blood flow during ATP infusion divided by that at rest. Patients were allocated to groups according to whether they had high (n = 64, EPA ≥ 75.8 μg/mL) or low (n = 63, EPA  2.5, which is the previously reported lower limit of normal flow reserve without obstructive CAD. Multivariate analysis revealed that EPA is an independent predictor of CFR > 2.5 (odds ratio, 1.01; 95% confidence interval, 1.00 – 1.02, p = 0.008). Conclusions The serum EPA is significantly correlated with CFR in CAD patients without significant coronary artery stenosis. PMID:24359564

  14. 16-Detector row computed tomographic coronary angiography in patients undergoing evaluation for aortic valve replacement: comparison with catheter angiography

    International Nuclear Information System (INIS)

    Manghat, N.E.; Morgan-Hughes, G.J.; Broadley, A.J.; Undy, M.B.; Wright, D.; Marshall, A.J.; Roobottom, C.A.

    2006-01-01

    Aim: To evaluate the diagnostic accuracy of 16-detector row computed tomography (CT) in assessing haemodynamically significant coronary artery stenoses in patients under evaluation for aortic stenosis pre-aortic valve replacement. Subjects and methods: Forty consecutive patients under evaluation for severe aortic stenosis and listed for cardiac catheterization before potential aortic valve replacement underwent coronary artery calcium (CAC) scoring and retrospective electrocardiogram (ECG)-gated multi-detector row computed tomographic coronary angiography (MDCTA) using a GE Lightspeed 16-detector row CT within 1 month of invasive coronary angiography (ICA) for comparative purposes. All 13 major coronary artery segments of the American Heart Association model were evaluated for the presence of ≥50% stenosis and compared to the reference standard. Data were analysed on a segment-by-segment basis and also in 'whole patient' terms. Results: A total of 412/450 segments from 35 patients were suitable for analysis. The overall accuracy of MDCTA for detection of segments with ≥50% stenosis was high, with a sensitivity of 81.3%, specificity 95.0%, positive predictive value (PPV) 57.8%, and negative predictive value (NPV) 98.4%. On a 'whole-patient' basis, 100% (19/19) of patients with significant coronary disease were correctly identified and there were no false-negatives. Excluding patients with CAC >1000 from the analysis improved the accuracy of MDCTA to: sensitivity 90%, specificity 98.1%, PPV 60%, NPV 99.7%. Conclusion: Non-invasive 16-detector row MDCTA accurately excludes significant coronary disease in patients with severe aortic stenosis undergoing evaluation before aortic valve replacement and in whom ICA can therefore be avoided. Its segment-by-segment accuracy is improved further if CAC > 1000 is used as a gatekeeper to MDCTA

  15. Radiosensitivity of lymphocytes in vitro

    International Nuclear Information System (INIS)

    Albrecht, S.

    1979-01-01

    The radiation-induced impairment of human T-lymphocytes was studied after in vitro exposure to 25.8 - 825.6 mC/kg (100 - 3200 R) of 60 Co γ-radiation by ascertaining the change in lymphocyte response to phytohaemagglutin stimulation. Following methods were used: (1) measurement of 3 H-thymidine uptake, (2) E-rosette test, and (3) morphological examination of transformed T-cells. The results revealed a dose-dependent decline in T-cell number which was still somewhat more marked with lymphocytes purified over Ficoll-Isopaque prior to irradiation. (author)

  16. Method for in vitro recombination

    Science.gov (United States)

    Gibson, Daniel Glenn; Smith, Hamilton O

    2013-05-07

    The present invention relates to an in vitro method, using isolated protein reagents, for joining two double-stranded (ds) DNA molecules of interest, wherein the distal region of the first DNA molecule and the proximal region of the second DNA molecule share a region of sequence identity. The method allows the joining of a number of DNA fragments, in a predetermined order and orientation, without the use of restriction enzymes. It can be used, e.g., to join synthetically produced sub-fragments of a gene or genome of interest.

  17. Applied in vitro radio bioassay

    International Nuclear Information System (INIS)

    Gaburo, J.C.G.; Sordi, G.M.A.A.

    1992-11-01

    The aim of this publication is to show the concepts and in vitro bioassay techniques as well as experimental procedures related with internal contamination evaluation. The main routes of intake, metabolic behavior, and the possible types of bioassay samples that can be collected for radionuclides analysis are described. Both biological processes and the chemical and physical behavior of the radioactive material of interest are considered and the capabilities of analytical techniques to detect and quantify the radionuclides are discussed. Next, the need of quality assurance throughout procedures are considered and finally a summary of the techniques applied to the internal routine monitoring of IPEN workers is given. (author)

  18. In vitro degradation of ribosomes.

    Science.gov (United States)

    Mora, G; Rivas, A

    1976-12-01

    The cytoplasmic ribosomes from Euglena gracilis var. bacillaris are found to be of two types taking into consideration their stability "in vitro". In the group of unstable ribosomes the large subunit is degraded. The other group apparently does not suffer any degradation under the conditions described. However the RNAs extracted from both types of ribosomes are degraded during sucrose density gradients. The degradation of the largest RNA species has been reported previously, but no comment has been made about the stability of the ribosome itself.

  19. Stenosing Tenosynovitis of the Flexor Hallucis Longus Tendon Associated with the Plantar Capsular Accessory Ossicle at the Interphalangeal Joint of the Great Toe

    Directory of Open Access Journals (Sweden)

    Song Ho Chang

    2017-01-01

    Full Text Available This report presents a case of stenosing tenosynovitis of the flexor hallucis longus tendon associated with the plantar capsular accessory ossicle at the interphalangeal joint of the great toe, which was confirmed by intraoperative observation and was successfully treated with surgical resection of the ossicle. As the plantar capsular accessory ossicle was not visible radiographically due to the lack of ossification, ultrasonography was helpful for diagnosing this disorder.

  20. Guyon's canal syndrome due to tortuous ulnar artery with DeQuervain stenosing tenosynovitis, ligamentous injuries and dorsal intercalated segmental instability syndrome, a rare presentation: a case report

    OpenAIRE

    Zeeshan, Muhammad; Ahmed, Farhan; Kanwal, Darakhshan; Khalid, Qazi Saad Bin; Ahmed, Muhammad Nadeem

    2009-01-01

    The Guyon's canal syndrome is a well known clinical entity and may have significant impact on patient's quality of life. We report a case of 43-year-old male who presented with complaints of pain and numbness in right hand and difficulty in writing for past one month. On imaging diagnosis of Guyon's canal syndrome because of tortuous ulnar artery was made with additional findings of DeQuervain's stenosing tenosynovitis and dorsal intercalated segmental instability syndrome with ligamentous in...

  1. Thallium-201 myocardial imaging during pharmacologic coronary vasodilation: comparison of oral and intravenous administration of dipyridamole

    International Nuclear Information System (INIS)

    Taillefer, R.; Lette, J.; Phaneuf, D.C.; Leveille, J.; Lemire, F.; Essiambre, R.

    1986-01-01

    Although the diagnostic utility of thallium-201 myocardial imaging after dipyridamole infusion is well established, the intravenous form of the drug is not yet commercially available in North America. Fifty patients referred for coronary angiography were prospectively studied. Within a 2 week period, each patient underwent cardiac catheterization and thallium-201 myocardial imaging after both oral and intravenous dipyridamole administration. For the oral protocol, patients were randomly assigned to treatment with either 200 or 400 mg of dipyridamole in tablet form. Coronary artery stenoses of 70% or greater were considered significant. For the 25 patients who received a 200 mg oral dose of dipyridamole, the scintigraphic study showed perfusion defects in 65% of patients with significant coronary artery disease after the oral dose and in 85% of patients after the intravenous dose. For the 25 patients who received a 400 mg oral dose, the sensitivity of the scintigram was 84% after the oral dose and 79% after the intravenous dose. Except for headache and nausea, side effects were less severe and less frequent with oral (either 200 or 400 mg) than with intravenous dipyridamole. Because of the delayed and variable absorption of dipyridamole tablets, the oral studies required a longer period of medical supervision (45 to 60 minutes), and aminophylline was empirically administered after completion of the first set of thallium-201 images. It is concluded from this study that thallium-201 myocardial imaging after coronary vasodilation with a 400 mg oral dose of dipyridamole is a safe, widely available and reliable alternative for the evaluation of coronary artery disease in patients unable to achieve an adequate exercise level on stress testing

  2. Acute Coronary Syndrome

    Science.gov (United States)

    ... heart cells are dying. An electrocardiogram (ECG or EKG) can diagnose an acute coronary syndrome by measuring ... Privacy Policy Popular Articles 1 Understanding Blood Pressure Readings 2 Sodium and Salt 3 Heart Attack Symptoms ...

  3. Coronary artery fistula

    Science.gov (United States)

    ... PA: Elsevier Saunders; 2015:chap 84. Friedman AH, Silverman NH. Congenital anomalies of the coronary arteries. In: ... provided by VeriMed Healthcare Network. Also reviewed by David Zieve, MD, MHA, Isla Ogilvie, PhD, and the ...

  4. Coronary Artery Disease

    DEFF Research Database (Denmark)

    Christiansen, Morten Krogh

    2017-01-01

    A family history of coronary artery disease (CAD) is an important risk factor for adverse coronary events, in particular if the disease has an early onset. The risk of CAD is influenced by genetic and environmental factors with a greater genetic contribution earlier in life. Through recent years......), and to characterize and quantify subclinical atherosclerosis in their relatives. Furthermore, the aim was to explore the impact of common genetic risk variants on the age of onset, familial clustering and disease severity. In study I, 143 patients with early- onset CAD were recruited from the Western Denmark Heart...... Registry and risk factor control was evaluated. The study revealed that risk factors are common in early-onset CAD and that a large room for risk factor improvement remains. In study II, we used coronary computed tomography angiography to compare the coronary plaque burden and characteristics between 88...

  5. Auxetic coronary stent endoprosthesis

    DEFF Research Database (Denmark)

    Amin, Faisal; Ali, Murtaza Najabat; Ansari, Umar

    2014-01-01

    BACKGROUND: Cardiovascular heart disease is one of the leading health issues in the present era and requires considerable health care resources to prevent it. The present study was focused on the development of a new coronary stent based on novel auxetic geometry which enables the stent to exhibit...... a negative Poisson's ratio. Commercially available coronary stents have isotropic properties, whereas the vascular system of the body shows anisotropic characteristics. This results in a mismatch between anisotropic-isotropic properties of the stent and arterial wall, and this in turn is not favorable...... for mechanical adhesion of the commercially available coronary stents with the arterial wall. It is believed that an auxetic coronary stent with inherent anisotropic mechanical properties and negative Poisson's ratio will have good mechanical adhesion with the arterial wall. METHODS: The auxetic design...

  6. Acute coronary syndrome

    Science.gov (United States)

    ... Have plenty of fruits, veggies, whole grains, and lean meats. Try to limit foods high in cholesterol ... et al. 2014 AHA/ACC guideline for the management of patients with non-ST-elevation acute coronary ...

  7. In vitro mutagenesis of roses

    International Nuclear Information System (INIS)

    Salahbiah Abdul Majid; Rusli Ibrahim

    2006-01-01

    In roses, numerous in vivo mutation induction experiments have been described, but only a few commercial mutants were published. The reason for this restriction may be that it sometimes takes a few years before mutants can be isolated and propagated by conventional methods. Roses mutate readily and most selected mutants concern flower colour, shape and plant type. A major problem for improvement of roses by means of mutation breeding is chimera formation, particularly when it aims to induce changes in quantitative characters. In vitro propagation could probably accelerate the isolation of periclinal chimera. Studies were conducted to investigate the potential of using gamma rays in orderto get mutations. Dormant axillary bud explants subjected to increasing doses of gamma rays showed a decrease in regeneration capacity, which was completely suppressed at 100 Gy. The lethal dose for 50 % of the regenerating explants (LD50) for both cut and miniature roses were observed between 20-40 Gy. For the main experiment, doses between 20 and 40 Gy were found to be most suitable for the induction of high mutation rate. A few new flower mutants, with new colour and shape were selected for further testing in order to produce stable mutants and this had to be micro propagated for a few generations. Thus, using axillary bud explants for the induction of mutation through in vitro shoots regeneration, several potential stable mutants of horticultural value were isolated. (Author)

  8. Initial clinical experience with a new percutaneous peripheral atherectomy device for the treatment of femoro-popliteal stenoses

    International Nuclear Information System (INIS)

    Zeller, T.; Frank, U.; Buergelin, K.; Schwarzwaelder, U.; Neumann, F.J.; Reimers, B.

    2004-01-01

    Background: Evaluation of the efficacy and safety of a new 7F-atherectomy device (30-day endpoint) for the treatment of short and mid-length arterial lesions with a reference diameter of 2.5-7 mm. Material and Methods: Fifty-eight femoto-popliteal stenoses in 46 patients (67% male, mean age 66± 9 years) with chronic peripheral occlusive disease of the lower limbs [Rutherford stage 2: n = 13 (28%); stage 3: n = 29 (63%); stage 4: 2 (4%), stage 5: n = 2 (4%]), were treated with directional atherectomy. Target lesion characteristics: Common femoral artery: n = 1 (2%), superficial femoral artery: n = 47 (81%); popliteal artery, n = 10 (17%); instent n = 3 (5%). Thirty (65%) of the interventions were performed using an antegrade approach, 16 (35%) interventions in cross-over technique. Mean degree of stenosis was 83 ± 11 mm, mean length of lesion was 37 ± 37 mm. Results: 6.5 ± 2 (4-10) passes of the lesion were performed with the catheter. Three lesions were treated after predilatation, 55 (95%) interventions as primary atherectomy. In 31/58 lesions (53%) additional balloon angioplasty was performed, in 1 lesion (2%) additional stent placement was needed. The mean degree of stenosis after atherectomy was reduced to 29 ± 20% (0-60%) after additional balloon angioplasty, it was 11 ± 10% (0-30%). A residual stenosis of [de

  9. Primary Cutting Balloon Angioplasty for Treatment of Venous Stenoses in Native Hemodialysis Fistulas: Long-Term Results from Three Centers

    International Nuclear Information System (INIS)

    Bhat, Rajesh; McBride, Kieran; Chakraverty, Sam; Vikram, Raghunandan; Severn, Alison

    2007-01-01

    Aim. To evaluate the technical success and patency rates following primary cutting balloon angioplasty for venous stenoses in native dialysis fistulas. Methods. Forty-one patients (26 men, 15 women; age range 26-82 years, average age 59 years) underwent 50 (repeat procedures in 9 patients) primary cutting balloon (PCB) angioplasty procedures in three institutions by three primary operators. The indication was primary stenosis in 21 patients, recurrent lesions in 15, and immature fistulas in 5. A PCB was used alone in 17 cases, but was followed by a larger standard balloon in 33 cases. Follow-up included ultrasound, flow analysis and urea reduction ratio, and ranged from 2 to 30 months (mean 14 months). Results. The technical success rate was 98%. All procedures were relatively painless. Two PCBs burst and 4 leaked, but without causing any morbidity. Nineteen fistulas were still working at last follow-up. Primary patency rates at 6, 12, and 24 months using Kaplan-Meier analysis were 88%, 73%, and 34%, respectively, and the primary assisted patencies were 90%, 75%, and 50%, respectively. Conclusion. PCB angioplasty has high technical success and low complication rates. The long-term patency rates are favorable for PCB angioplasty and compare favorably with other series

  10. Actual review of diagnostics and endovascular therapy of intracranial arterial stenoses; Diagnostik und endovaskulaere Therapie intrakranieller arterieller Stenosen

    Energy Technology Data Exchange (ETDEWEB)

    Gizewski, E.R. [Universitaetsklinikum Essen (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie und Neuroradiologie; Weber, R. [Universitaetsklinikum Essen (Germany). Klinik fuer Neurologie; Forsting, M. [Universitaetsklinikum Giessen und Marburg, Giessen (Germany). Abt. fuer Neuroradiologie

    2011-02-15

    Approximately 6 - 50 % of all ischemic strokes are caused by intracranial arterial stenosis (IAS). Despite medical prevention, patients with symptomatic IAS have a high annual risk for recurrent ischemic stroke of about 12 %, and up to 19 % in the case of high-grade IAS ({>=} 70 %). Digital subtraction angiography remains the gold standard for the diagnosis and grading of IAS. However, noninvasive imaging techniques including CT angiography, MR angiography, or transcranial Doppler and duplex ultrasound examinations are used in the clinical routine to provide additional information about the brain structure and hemodynamic. However, for technical reasons, the grading of stenoses is sometimes difficult and inaccurate. To date, aspirin is recommended as the treatment of choice in the prevention of recurrent ischemic stroke in patients with IAS. IAS patients who suffer a recurrent ischemic stroke or transient ischemic attack while taking aspirin can be treated with endovascular stenting or angioplasty in specialized centers. The periprocedural complication rate of these endovascular techniques is about 2 - 7 % at experienced neuro-interventional centers. The rate of re-stenosis is reported between 10 and 40 % depending on patient age and stenosis location. Further randomized studies comparing medical secondary prevention and endovascular therapy are currently being performed. With regard to the improvement of endovascular methods and lower complication rates, the indication for endovascular therapy in IAS could be broadened especially for stenosis in the posterior circulation. (orig.)

  11. Impulsion of nanoparticles as a drug carrier for the theoretical investigation of stenosed arteries with induced magnetic effects

    Energy Technology Data Exchange (ETDEWEB)

    Nadeem, S.; Ijaz, S., E-mail: shagufta.me2011@yahoo.com

    2016-07-15

    In this paper hemodynamics of stenosis are discussed to predict effect of atherosclerosis by means of mathematical models in the presence of uniform transverse magnetic field. The analysis is carried out using silver and copper nanoparticles as a drug carrier. Exact solution for the fluid temperature, velocity, axial induced magnetic field and current density distribution are obtained under mild stenosis approximation. The results indicate that with an increase in the concentration of nanoparticle hemodynamics effects of stenosis reduces throughout the inclined composite stenosed arteries. The considered analysis also summarizes that the drug silver nanoparticles is more efficient to reduce hemodynamics of stenosis when compare to the drug copper nanoparticle. In future this model could be helpful to predict important properties in some biomedical applications. - Highlights: • The contribution of copper and silver nanoparticles as drug carrier reveals that they are important to reduce hemodynamic of stenosis. • The heat is dissipated throughout the considered inclined artery with an increase in the nanoparticle volume fraction. • The stress on the wall of inclined arteries decreases with an increase in the magnetic Reynolds number and Strommers number.

  12. Coronary hemodynamics in vasospastic angina

    International Nuclear Information System (INIS)

    Matsumura, Kentaro; Kubota, Shinobu; Serizawa, Takashi; Nakase, Emiko; Kawai, Ichiro; Saito, Takayuki

    1991-01-01

    To evaluate the coronary circulation and myocardial perfusion dynamics, we performed left coronary digital subtraction angiography (DSA) in 35 patients with vasospastic angina. The left coronary circulation time (CCT) measured from the proximal left coronary artery to the coronary sinus was 5.77±0.86 sec, and the left epicardial conducting artery transmission time (CAT) measured from the proximal left coronary artery to the apical area was 2.65±0.82 sec in normal controls. The CCT and CAT were significantly prolonged in patients with vasospastic angina, indicating that the coronary peripheral vascular resistance is probably greater after the cessation of nitrates and Ca ++ -antagonists. After the intracoronary injection of ergonovine malate, the CCT was slightly shortened, but the apical T 1/2 was significantly prolonged in patients with vasospastic angina. This suggested that coronary vasospasm is present not only in the epicardial arteries but also in coronary arteries with peripheral resistance. These phenomena were not observed in normal controls. We performed left coronary DSA after conventional left coronary cineangiography. When the CCT exceeded 6.7 sec, we considered that the coronary circulation was significantly impaired. We concluded that the coronary DSA is very useful for evaluating abnormal coronary circulation in patients with vasospastic angina during myocardial perfusion. (author)

  13. Physical model of the haemodynamic effects around the obstructing plaque in the acute coronary syndromes take account of the stenosis geometry

    International Nuclear Information System (INIS)

    Matveev, M.

    2004-01-01

    Selective coronary angiography with quantitative parameter assessment of the vessel stenosis geometry, which leads to acute coronary syndrome, was performed in 205 patients undergoing acute phase of myocardial infarction or unstable angina pectoris. Data for physicomechanical properties of the arterial vessels, blood and blood flow were used. The range of pressure variations accompanying the most frequently encountered ruptures of the atherosclerotic plaques was analyzed with physical model. It suggests that in 'lock' type plaques the ratio between the pressure on the wall of the normal vessel and that in the section outside the stenosis is considerably increased, especially in cases of enlarged vessel gauge. The results obtained show that the wall pressure closely to the plaque of a stenosed vessel with normal diameter of 3.5 mm exceeds 25 times the pressure within a normal vessel segment. (author)

  14. HEMOPERFUSION DURING CORONARY ANGIOPLASTY - 1ST EUROPEAN EXPERIENCE WITH A NEW HEMOPERFUSION PUMP

    NARCIS (Netherlands)

    DEMUINCK, ED; MEEDER, J; MAGIELSE, C; BOM, VJJ; VANDIJK, RB; VERKERKE, GJ; LIE, KI

    Hemolysis tests with fresh human blood were performed in vitro with a new 5 ml, piston-type hemoperfusion pump, designed to prevent myocardial ischemia during coronary angioplasty. Despite driving pressures greater than 3 atmospheres, shear stress greater than 200 Pa, turbulent pump flow, and the

  15. Silicon-carbide coated coronary stents have low platelet and leukocyte adhesion during platelet activation

    NARCIS (Netherlands)

    Monnink, SHJ; van Boven, AJ; Tigchelaar, [No Value; de Kam, PJ; Crijns, HJGM; van Oeveren, W

    Background: Stent thrombosis and restenosis are of great clinical significance. We constructed a closed loop in vitro heparinized whole human blood circulation model for testing hemocompatibility of coronary stents, This model allows evaluation of human blood activation by blood-stent interaction in

  16. Coronary tortuosity: a long and winding road.

    NARCIS (Netherlands)

    Zegers, E.S.; Meursing, B.T.J.; Oude Ophuis, A.J.M.

    2007-01-01

    Coronary tortuosity is a phenomenon often encountered by cardiologists performing coronary angiography. The aetiology and clinical importance of coronary tortuosity are still unclear. Coronary tortuosity without fixed atherosclerotic stenosis in patients with angina pectoris and an abnormal exercise

  17. Coronary Artery Anomalies in Animals

    Directory of Open Access Journals (Sweden)

    Brian A. Scansen

    2017-04-01

    Full Text Available Coronary artery anomalies represent a disease spectrum from incidental to life-threatening. Anomalies of coronary artery origin and course are well-recognized in human medicine, but have received limited attention in veterinary medicine. Coronary artery anomalies are best described in the dog, hamster, and cow though reports also exist in the horse and pig. The most well-known anomaly in veterinary medicine is anomalous coronary artery origin with a prepulmonary course in dogs, which limits treatment of pulmonary valve stenosis. A categorization scheme for coronary artery anomalies in animals is suggested, dividing these anomalies into those of major or minor clinical significance. A review of coronary artery development, anatomy, and reported anomalies in domesticated species is provided and four novel canine examples of anomalous coronary artery origin are described: an English bulldog with single left coronary ostium and a retroaortic right coronary artery; an English bulldog with single right coronary ostium and transseptal left coronary artery; an English bulldog with single right coronary ostium and absent left coronary artery with a prepulmonary paraconal interventricular branch and an interarterial circumflex branch; and a mixed-breed dog with tetralogy of Fallot and anomalous origin of all coronary branches from the brachiocephalic trunk. Coronary arterial fistulae are also described including a coronary cameral fistula in a llama cria and an English bulldog with coronary artery aneurysm and anomalous shunting vessels from the right coronary artery to the pulmonary trunk. These examples are provided with the intent to raise awareness and improve understanding of such defects.

  18. Temporary Vascular Occlusion by Rapid Reverse Phase Polymer: A Preliminary In Vitro Study of Retrograde Injection

    Directory of Open Access Journals (Sweden)

    Einar Dregelid

    2012-01-01

    Full Text Available During vascular surgical operations, there is a need for a simpler and more reliable method of temporary arterial occlusion than those currently employed, especially of heavily calcified arteries. A thermosensitive polymer, LeGoo (LG (Pluromed, Woburn, MA, has been used successfully for temporary vascular occlusion. It has hitherto been injected by a cannula that has been introduced into the artery to be occluded, here henceforth called the “cannulation method.” Injection into arterial ostia without cannulation, using an injection device that arrests blood flow during the injection, here henceforth called “a retrograde method” may enable temporary hemostasis when ostial stenoses render it impossible to inject LG using the cannulation method. The objective of the present study was to study the feasibility of a retrograde method and to compare it with the cannulation method in an in vitro model, incorporating a narrow orifice to simulate ostial stenosis, using tap water at 37°C instead of blood. The retrograde method of LG injection, using a modified paediatric Foley catheter, turned out to be feasible to produce a durable LG plug more reliably, at higher water pressure and with less deep LG injection than with the cannulation method.

  19. MR Angiography of Peripheral Arterial Stents: In Vitro Evaluation of 22 Different Stent Types

    Directory of Open Access Journals (Sweden)

    Matthias C. Burg

    2011-01-01

    Full Text Available Purpose. To evaluate stent lumen visibility of a large sample of different peripheral arterial (iliac, renal, carotid stents using magnetic resonance angiography in vitro. Materials and Methods. 21 different stents and one stentgraft (10 nitinol, 7 316L, 2 tantalum, 1 cobalt superalloy, 1 PET + cobalt superalloy, and 1 platinum alloy were examined in a vessel phantom (vessel diameters ranging from 5 to 13 mm filled with a solution of Gd-DTPA. Stents were imaged at 1.5 Tesla using a T1-weighted 3D spoiled gradient-echo sequence. Image analysis was performed measuring three categories: Signal intensity in the stent lumen, lumen visibility of the stented lumen, and homogeneity of the stented lumen. The results were classified using a 3-point scale (good, intermediate, and poor results. Results. 7 stents showed good MR lumen visibility (4x nitinol, 2x tantalum, and 1x cobalt superalloy. 9 stents showed intermediate results (5x nitinol, 2x 316L, 1x PET + cobalt superalloy, and 1x platinum alloy and 6 stents showed poor results (1x nitinol, and 5x 316L. Conclusion. Stent lumen visibility varies depending on the stent material and type. Some products show good lumen visibility which may allow the detection of stenoses inside the lumen, while other products cause artifacts which prevent reliable evaluation of the stent lumen with this technique.

  20. In-vitro study on haemodiluted blood flow in a sinusoidal microstenosis.

    Science.gov (United States)

    Kang, M J; Ji, H-S; Lee, S J

    2010-01-01

    In-vitro experiments were carried out to investigate the haemodynamic and haemorheological behaviours of haemodiluted blood flow through a microstenosis using a micro-particle image velocimetry (PIV) technique. The micro-PIV system employed in this study consisted of a two-head neodymium:yttrium-aluminium-garnet (Nd:YAG) laser, a cooled charge-coupled device camera, and a delay generator. To simulate blood flow in a stenosed vascular vessel, a polydimethylsiloxane (PDMS) microchannel with a sinusoidal throat of 80 per cent severity was employed. The width and depth of the microchannel were 100 microm and 50 microm, respectively. To compare the flow characteristics in the microstenosis, the same experiments were repeated in a straight microchannel under the same flow conditions. Using a syringe pump, human blood with 5 per cent haematocrit was supplied into the microstenosis channel. The flow characteristics and transport of blood cells through the microstenosis were investigated with various flowrates. The mean velocity fields were nearly symmetric with respect to the channel centreline. In the contraction section, the oncoming blood flow was accelerated rapidly, and the maximum velocity at the throat was almost 4.99 times faster than that of the straight microchannel without stenosis. In the diffusion section, the blood cells show rolling, deformation, twisting, and tumbling motion due to the flow-choking characteristics at the stenotic region. The results from this study will provide useful basic data for comparison with those obtained by clinical researchers.

  1. Cross-reacting antibacterial auto-antibodies are produced within coronary atherosclerotic plaques of acute coronary syndrome patients.

    Directory of Open Access Journals (Sweden)

    Filippo Canducci

    Full Text Available Coronary atherosclerosis, the main condition predisposing to acute myocardial infarction, has an inflammatory component caused by stimuli that are yet unknown. We molecularly investigated the nature of the immune response within human coronary lesion in four coronary plaques obtained by endoluminal atherectomy from four patients. We constructed phage-display libraries containing the IgG1/kappa antibody fragments produced by B-lymphocytes present in each plaque. By immunoaffinity, we selected from these libraries a monoclonal antibody, arbitrarily named Fab7816, able to react both with coronary and carotid atherosclerotic tissue samples. We also demonstrated by confocal microscopy that this monoclonal antibody recognized human transgelin type 1, a cytoskeleton protein involved in atherogenesis, and that it co-localized with fibrocyte-like cells transgelin+, CD68+, CD45+ in human sections of coronary and carotid plaques. In vitro fibrocytes obtained by differentiating CD14+ cells isolated from peripheral blood mononuclear cells also interacted with Fab7816, thus supporting the hypothesis of a specific recognition of fibrocytes into the atherosclerotic lesions. Interestingly, the same antibody, cross-reacted with the outer membrane proteins of Proteus mirabilis and Klebsiella pneumoniae (and possibly with homologous proteins of other enterobacteriaceae present in the microbiota. From all the other three libraries, we were able to clone, by immunoaffinity selection, human monoclonal antibodies cross-reacting with bacterial outer membrane proteins and with transgelin. These findings demonstrated that in human atherosclerotic plaques a local cross-reactive immune response takes place.

  2. Calcified Plaque of Coronary Artery: Factors Influencing Overestimation of Coronary Artery Stenosis on Coronary CT Angiography

    International Nuclear Information System (INIS)

    Kim, Mok Hee; Kim, Yun Hyeon; Choi, Song; Seon, Hyun Ju; Jeong, Gwang Woo; Park, Jin Gyoon; Kang, Heoung Keun; Ko, Joon Seok

    2010-01-01

    To assess the influence of calcified plaque characteristics on the overestimation of coronary arterial stenosis on a coronary CT angiography (CCTA). The study included 271 coronary arteries with calcified plaques identified by CCTA, and based on 928 coronary arteries from 232 patients who underwent both CCTA and invasive coronary angiography (ICA). Individual coronary arteries were classified into two groups by agreement based on the degree of stenosis from each CCTA and ICA: 1) group A includes patients with concordant CCTA and ICA results and, 2) group B includes patients with an overestimation of CCTA compared to ICA. Parameters including total calcium score, calcium score of an individual coronary artery, calcium burden number of an individual coronary artery, and the density of each calcified plaque (calcium score / number of calcium burden) for each individual coronary artery were compared between the two groups. Of the 271 coronary arteries, 164 (60.5%) were overestimated on CCTA. The left anterior descending artery (LAD) had a significantly low rate of overestimation (47.1%) compared to the other coronary arteries (p=0.001). No significant differences for total calcium score, calcium score of individual coronary artery, and the density of each calcified plaque from individual coronary arteries between two groups was observed. However, a decreasing tendency for the rate of overestimation on CCTA was observed with an increase in calcium burden of individual coronary arteries (p<0.05). The evaluation of coronary arteries suggests that the degree of coronary arterial stenosis had a tendency to be overestimated by calcified plaques on CCTA. However, the rate of overestimation for the degree of coronary arterial stenosis by calcified plaques was not significantly influenced by total calcium score, calcium score of individual coronary artery, and density of each calcified plaque

  3. The Ethics of Producing In Vitro Meat

    OpenAIRE

    Schaefer, G Owen; Savulescu, Julian

    2014-01-01

    The prospect of consumable meat produced in a laboratory setting without the need to raise and slaughter animals is both realistic and exciting. Not only could such in vitro meat become popular due to potential cost savings, but it also avoids many of the ethical and environmental problems with traditional meat productions. However, as with any new technology, in vitro meat is likely to face some detractors. We examine in detail three potential objections: 1) in vitro meat is disrespectful, e...

  4. Distal coronary hemoperfusion during percutaneous transluminal coronary angioplasty

    NARCIS (Netherlands)

    Muinck, Ebo Derk de

    1994-01-01

    In this thesis several aspects of passive and active coronary perfusion during coronary angioplasty are investigated. The autoperfusion balloon catheters that were evaluated are the Stack® and the RX-60® catheters (Advanced Cardiovascular Systems, inc., Santa Clara, California, U.S.A). The coronary

  5. Advanced computed tomographic anatomical and morphometric plaque analysis for prediction of fractional flow reserve in intermediate coronary lesions

    International Nuclear Information System (INIS)

    Opolski, Maksymilian P.; Kepka, Cezary; Achenbach, Stephan; Pregowski, Jerzy; Kruk, Mariusz; Staruch, Adam D.; Kadziela, Jacek; Ruzyllo, Witold; Witkowski, Adam

    2014-01-01

    Objective: To determine the application of advanced coronary computed tomography angiography (CCTA) plaque analysis for predicting invasive fractional flow reserve (FFR) in intermediate coronary lesions. Methods: Sixty-one patients with 71 single intermediate coronary lesions (≥50–80% stenosis) on CCTA prospectively underwent coronary angiography and FFR. Advanced anatomical and morphometric plaque analysis was performed based on CCTA data set to determine optimal criteria for significant flow impairment. A significant stenosis was defined as FFR ≤ 0.80. Results: FFR averaged 0.85 ± 0.09, and 19 lesions (27%) were functionally significant. FFR correlated with minimum lumen area (MLA) (r = 0.456, p < 0.001), minimum lumen diameter (MLD) (r = 0.326, p = 0.006), reference lumen diameter (RLD) (r = 0.245, p = 0.039), plaque burden (r = −0.313, p = 0.008), lumen area stenosis (r = −0.305, p = 0.01), lesion length (r = −0.692, p < 0.001), and plaque volume (r = −0.668, p < 0.001). There was no relationship between FFR and CCTA morphometric plaque parameters. By multivariate analysis the independent predictors of FFR were lesion length (beta = −0.581, p < 0.001), MLA (beta = 0.360, p = 0.041), and RLD (beta = −0.255, p = 0.036). The optimal cutoffs for lesion length, MLA, MLD, RLD, and lumen area stenosis were >18.5 mm, ≤3.0 mm 2 , ≤2.1 mm, ≤3.2 mm, and >69%, respectively (max. sensitivity: 100% for MLA, max. specificity: 79% for lumen area stenosis). Conclusions: CCTA predictors for FFR support the mathematical relationship between stenosis pressure drop and coronary flow. CCTA could prove to be a useful rule-out test for significant hemodynamic effects of intermediate coronary stenoses

  6. Significance of dipyridamole-induced transient dilation of the left ventricle during thallium-201 scintigraphy in suspected coronary artery disease

    International Nuclear Information System (INIS)

    Chouraqui, P.; Rodrigues, E.A.; Berman, D.S.; Maddahi, J.

    1990-01-01

    The occurrence and significance of transient dilation of the left ventricle during dipyridamole stress-redistribution thallium-201 scintigraphy was studied in 73 patients who underwent both dipyridamole thallium-201 study and coronary angiography. Transient dilation ratio was calculated from planar anterior images by dividing the computer-derived left ventricular area on the initial image by that of the 4-hour image. In 11 patients with normal coronary arteriograms or less than 50% coronary stenosis, the transient dilation ratio was 0.98 +/- 0.046. An abnormal transient dilation ratio was defined as greater than or equal to 1.12, representing greater than or equal to 3 standard deviations above the mean normal value. When the 15 patients with an abnormal ratio were compared with the 58 with a normal ratio, the former group had a significantly higher frequency of 3 critical (greater than or equal to 90%) coronary stenoses (33 vs 5%), higher prevalence of collaterals (67 vs 24%), more extensive myocardial reversible defects by planar (71 vs 10%) or by single-photon emission computed tomography (87.5 vs 35%) imaging and a higher incidence of dipyridamole-induced anginal chest pain (53 vs 22%). No significant difference between the 2 groups was noted with respect to age, gender, prior myocardial infarction, single or double critical coronary stenosis, dipyridamole-induced ischemic electrocardiographic response and increased lung uptake. An abnormal transient dilation ratio of greater than or equal to 1.12 was a specific marker of multivessel (87%) or 3-vessel (85%) critical coronary artery disease

  7. Multidetector CT evaluation of central airways stenoses: Comparison of virtual bronchoscopy, minimal-intensity projection, and multiplanar reformatted images

    Directory of Open Access Journals (Sweden)

    Dinesh K Sundarakumar

    2011-01-01

    Full Text Available Aims: To evaluate the diagnostic utility of virtual bronchoscopy, multiplanar reformatted images, and minimal-intensity projection in assessing airway stenoses. Settings and Design: It was a prospective study involving 150 patients with symptoms of major airway disease. Materials and Methods: Fifty-six patients were selected for analysis based on the detection of major airway lesions on fiber-optic bronchoscopy (FB or routine axial images. Comparisons were made between axial images, virtual bronchoscopy (VB, minimal-intensity projection (minIP, and multiplanar reformatted (MPR images using FB as the gold standard. Lesions were evaluated in terms of degree of airway narrowing, distance from carina, length of the narrowed segment and visualization of airway distal to the lesion. Results: MPR images had the highest degree of agreement with FB (Κ = 0.76 in the depiction of degree of narrowing. minIP had the least degree of agreement with FB (Κ = 0.51 in this regard. The distal visualization was best on MPR images (84.2%, followed by axial images (80.7%, whereas FB could visualize the lesions only in 45.4% of the cases. VB had the best agreement with FB in assessing the segment length (Κ = 0.62. Overall there were no statistically significant differences in the measurement of the distance from the carina in the axial, minIP, and MPR images. MPR images had the highest overall degree of confidence, namely, 70.17% (n = 40. Conclusion: Three-dimensional reconstruction techniques were found to improve lesion evaluation compared with axial images alone. The technique of MPR images was the most useful for lesion evaluation and provided additional information useful for surgical and airway interventions in tracheobronchial stenosis. minIP was useful in the overall depiction of airway anatomy.

  8. Endoscopic stenting for common bile duct stenoses in chronic pancreatitis: results and impact on long-term outcome.

    Science.gov (United States)

    Eickhoff, A; Jakobs, R; Leonhardt, A; Eickhoff, J C; Riemann, J F

    2001-10-01

    The overall incidence of common bile duct strictures due to chronic pancreatitis is reported to be approximately 10-30%. It remains a challenging problem for gastroenterologists and surgeons. The exact role of endoscopic stenting has not yet been clearly defined. Thirty-nine patients with chronic pancreatitis and symptomatic common bile duct stenoses underwent endoscopic stenting and were studied retrospectively. We were particularly interested in how many patients would achieve resolution of the stricture and tolerate removal of the stents in the long term. Indications for endoscopic stenting were symptomatic cholestasis, jaundice or cholangitis. The initial serum bilirubin was 8.3 mg/dl and the diameter of the common bile duct was 14.2 mm before stenting. Within 3-7 days of stenting, all patients presented improvement of jaundice and cholestasis. After a median stenting time of 9 months (range 1-144 months), 46% of the patients demonstrated regression of the stricture and clinical improvement, 26% required further stenting, and 28% were referred to surgery. Five patients received a self-expandable metal Wallstent. Thirty-one per cent demonstrated complete clinical recovery of the stricture as well as 10.2% a complete, radiologically verified stricture regression in a median follow-up of 58 months. There seems to be a therapeutic benefit for short-term endoscopic treatment but medium-term and long-term outcome remains questionable. Endoscopic stenting should be applied as an initial therapy before surgery, but it can be the definitive approach for older and morbid patients or cases with complete stricture regression after stent removal. Overall, it should not be considered as a routine procedure for symptomatic cases.

  9. Nuclear cardiology and coronary surgery

    DEFF Research Database (Denmark)

    Eckardt, R.; Andersen, L.I.; Hesse, B.

    2008-01-01

    Rising age, repeated percutaneous coronary revascularizations, and co-morbidity such as overweight, diabetes, and hypertension, characterize a change over the last 20-30 years in coronary patients referred to coronary artery bypass grafting (CABG). This patient group represents a great part of to...

  10. Regeneration of Pelargonium in vitro

    Directory of Open Access Journals (Sweden)

    Agnieszka Wojtania

    2013-12-01

    Full Text Available Pelargonium sp. has been a subject of numerous studies to deterimine the effec tiveness of in vitro techniques to produce a large number of pathogen-free plants. Regeneration of pelargonium plants from the different initial explants as well via organogenesis as via somatic embryogenesis has been obtained. The most effective adventitious shoot formation has been achieved from shoot tips and axillary buds using cytokinin or cytokinin/auxin combinations. Leaf explants, whose general have lower organogenic potency, regenerate better in the presence of thidiazuron. This growth regulator stimulate the somatic embryos production from hypocotyl and cotyledone explants too. The main problem in tissue culture propagation of Pelargonium has been the high tendency to formation of vigorously growing callus with low organogenic potency and rapid senescence of cultures. Moreover, the significant differen ces in requirements to the medium composition (minerals, organic compounds and growth regulators between Pelargonium cultivars has been observed. This makes difficult to develop an universaI method of Pelargonium micropropagation.

  11. In vitro assembly of catalase.

    Science.gov (United States)

    Baureder, Michael; Barane, Elisabeth; Hederstedt, Lars

    2014-10-10

    Most aerobic organisms contain catalase, which functions to decompose hydrogen peroxide. Typical catalases are structurally complex homo-tetrameric enzymes with one heme prosthetic group buried in each subunit. It is not known how catalase in the cell is assembled from its constituents. The bacterium Enterococcus faecalis cannot synthesize heme but can acquire it from the environment to form a cytoplasmic catalase. We have in E. faecalis monitored production of the enzyme polypeptide (KatA) depending on the availability of heme and used our findings to devise a procedure for the purification of preparative amounts of in vivo-synthesized apocatalase. We show that fully active catalase can be obtained in vitro by incubating isolated apoprotein with hemin. We have characterized features of the assembly process and describe a temperature-trapped hemylated intermediate of the enzyme maturation process. Hemylation of apocatalase does not require auxiliary cell components, but rapid assembly of active enzyme seemingly is assisted in the cell. Our findings provide insight about catalase assembly and offer new experimental possibilities for detailed studies of this process. © 2014 by The American Society for Biochemistry and Molecular Biology, Inc.

  12. In Vitro Assembly of Catalase*

    Science.gov (United States)

    Baureder, Michael; Barane, Elisabeth; Hederstedt, Lars

    2014-01-01

    Most aerobic organisms contain catalase, which functions to decompose hydrogen peroxide. Typical catalases are structurally complex homo-tetrameric enzymes with one heme prosthetic group buried in each subunit. It is not known how catalase in the cell is assembled from its constituents. The bacterium Enterococcus faecalis cannot synthesize heme but can acquire it from the environment to form a cytoplasmic catalase. We have in E. faecalis monitored production of the enzyme polypeptide (KatA) depending on the availability of heme and used our findings to devise a procedure for the purification of preparative amounts of in vivo-synthesized apocatalase. We show that fully active catalase can be obtained in vitro by incubating isolated apoprotein with hemin. We have characterized features of the assembly process and describe a temperature-trapped hemylated intermediate of the enzyme maturation process. Hemylation of apocatalase does not require auxiliary cell components, but rapid assembly of active enzyme seemingly is assisted in the cell. Our findings provide insight about catalase assembly and offer new experimental possibilities for detailed studies of this process. PMID:25148685

  13. Anomalous origin of right coronary artery from left coronary sinus.

    Science.gov (United States)

    Hamzeh, Gadah; Crespo, Alex; Estarán, Rafael; Rodríguez, Miguel A; Voces, Roberto; Aramendi, José I

    2008-08-01

    Anomalous aortic origin of the coronary arteries is uncommon but clinically significant. Manifestations vary from asymptomatic patients to those who present with angina pectoris, myocardial infarction, heart failure, syncope, arrhythmias, and sudden death. We describe 4 patients, aged 34 to 59 years, who were diagnosed with right coronary artery arising from the left sinus of Valsalva, confirmed by coronary angiography, which was surgically repaired. Three patients presented dyspnea and angina, and one with acute myocardial infarction. At operation, the right coronary artery was dissected at the take-off from the intramural course, and reimplanted into the right sinus of Valsalva. There was no mortality. One patient had associated coronary artery disease that required stent placement postoperatively. This reimplantation technique provides a good physiological and anatomical repair, eliminates a slit-like ostium, avoids compression of the coronary artery between the aorta and the pulmonary artery, and gives superior results to coronary artery bypass grafting or the unroofing technique.

  14. What is in vitro meat? Food phreaking

    OpenAIRE

    Stephens, NS

    2015-01-01

    This book gathers the ideas and opinions of a number of scientists and other experts around the topic of in vitro meat. The authors in this publication range from being in vitro meat’s developers and most vocal supporters, to some adamant opposers. Collectively, these essays present a diversity of perspectives, and illustrate the challenge of pinning down an emerging technology.

  15. Chemical composition, secondary metabolites, in vitro gas ...

    African Journals Online (AJOL)

    Chemical composition, secondary metabolites, in vitro gas production characteristics and acceptability study of some forage for ruminant feeding in South-Western Nigeria. ... Chemical composition and qualitative analysis of saponins, phenol and steroids of the plants were determined. In vitro gas production (IVGP) was ...

  16. Complex Coronary Interventions with the Novel Mozec™ CTO Balloon: The MOZART Registry.

    Science.gov (United States)

    Lupi, Alessandro; Rognoni, Andrea; Schaffer, Alon; Secco, Gioel G; Bongo, Angelo S

    2015-01-01

    Mozec™ CTO is a novel semicompliant rapid-exchange PTCA balloon catheter with specific features dedicated to treat complex coronary lesions like chronic total occlusions (CTOs). However, no data have been reported about the performance of this device in an all-comers population with complex coronary lesions. We evaluated the safety and success rate of Mozec™ CTO balloon in 41 consecutive patients with chronic stable angina and complex coronary lesions (15 severe calcified coronary stenoses, 15 bifurcation lesions with planned two-stent intervention, and 11 CTOs). Safety was assessed reporting the balloon burst rate after inflation exceeding the rated burst pressure (RBP) according to the manufacturer's reference table. Success was defined as the possibility to advance the device further the target lesion. The Mozec™ CTO balloon showed an excellent performance with a 93.3% success in crossing tight and severely calcified lesions (14/15 pts), a 93.3% success in engaging jailed side branches after stent deployment across bifurcations (14/15 pts), and a 90.9% success in crossing CTO lesions (10/11 pts). The burst rate at RBP of the Mozec™ CTO balloon was 6.7% (1/15 balloons) in the tight and severely calcified lesions, 6.7% (1/15 balloons) when dilating jailed vessels, and 9.1% (1/11 balloons) in CTOs. The novel Mozec™ CTO balloon dilatation catheter showed promising results when employed to treat complex lesions in an all-comers population. Further studies should clarify if this kind of balloon might reduce the need of more costly devices like over-the-wire balloons and microcatheters for complex lesions treatment.

  17. Percutaneous coronary intervention versus coronary-artery bypass grafting for severe coronary artery disease

    NARCIS (Netherlands)

    P.W.J.C. Serruys (Patrick); M-C. Morice (Marie-Claude); A.P. Kappetein (Arie Pieter); A. Colombo (Antonio); D.R. Holmes Jr (David); M.J. Mack (Michael); E. Stahle (Elisabeth); T.E. Feldman (Ted); M.J.B.M. van den Brand (Marcel); E.J. Bass (Eric); N. van Dyck (Nic); K. Leadly (Katrin); K.D. Dawkins (Keith); F.W. Mohr (Friedrich)

    2009-01-01

    textabstractBACKGROUND Percutaneous coronary intervention (PCI) involving drug-eluting stents is increasingly used to treat complex coronary artery disease, although coronary-artery bypass grafting (CABG) has been the treatment of choice historically. Our trial compared PCI and CABG for treating

  18. Use of the covered Y-shaped metallic stent in the treatment of airway stenoses involving the lower trachea and the tracheal carina: preliminary clinical study

    International Nuclear Information System (INIS)

    Yang Ruimin; Li Fenbao; Zhang Mingqiu; Wu Gang; Han Xinwei

    2007-01-01

    Objective: To describe a new kind of Y-shaped metallic stent delivery system and evaluate its feasibility and preliminary effect for managing multiple airway stenoses involving the lower trachea and the tracheal carina. Methods: The Y-shaped metallic stent delivery system consisted of three-tier structure. The inner-tier was composed of four parallel guiding tubes, which was used for two guidewires and two threads passing through, the middle-tier was delivery catheter, which contained the four guiding tubes, and the outer-tier was introducer sheath. Under the fluoroscopic guidance, 15 patients with multiple stenoses involving the lower trachea and the tracheal carina were treated with the new covered self-expandable Y-shaped metallic stents. Results: Stent placement in the tracheo-bronchial tree was technically successful in all patients with obliteration of the dyspnea immediately after stent placement, and SaO2 was increased form preoperative 75%-89% to postoperative 96%-99%. During follow-up a period of 3-58 weeks (M 22 weeks), all stenosis were resolved without stent-related complications, and the general physical of all 15 patents was improved with no occurrence of obviously dyspnea and bleeding. Karnofsky performance status (KPS) was improved from preoperative 26%-45% to postoperative 72%-95%. Five patients died of the following causes unrelated to stent insertion: multiple organ failure (n=3), cachexia (n=1) and pulmonary infection caused by gastrobronehial fistula (n=1), and the remaining 10 patients were alive with no evidence of dyspnea at the time of this report. Conclusion: Deployment of the covered Y-shaped metallic stent with the use of Y metallic stent delivery system in the management of airway stenoses involving the lower trachea and the tracheal carina was a simple and safe procedure and with a good short-term clinical efficacy. (authors)

  19. Use of the covered Y-shaped metallic stent in the treatment of airway stenoses involving the lower trachea and the tracheal carina: preliminary clinical study

    Energy Technology Data Exchange (ETDEWEB)

    Ruimin, Yang; Fenbao, Li; Mingqiu, Zhang [Department of Intervention, First Affiliated Hospital, Xinxiang Medical Univ., Xinxiang (China); Gang, Wu; Xinwei, Han

    2007-09-15

    Objective: To describe a new kind of Y-shaped metallic stent delivery system and evaluate its feasibility and preliminary effect for managing multiple airway stenoses involving the lower trachea and the tracheal carina. Methods: The Y-shaped metallic stent delivery system consisted of three-tier structure. The inner-tier was composed of four parallel guiding tubes, which was used for two guidewires and two threads passing through, the middle-tier was delivery catheter, which contained the four guiding tubes, and the outer-tier was introducer sheath. Under the fluoroscopic guidance, 15 patients with multiple stenoses involving the lower trachea and the tracheal carina were treated with the new covered self-expandable Y-shaped metallic stents. Results: Stent placement in the tracheo-bronchial tree was technically successful in all patients with obliteration of the dyspnea immediately after stent placement, and SaO2 was increased form preoperative 75%-89% to postoperative 96%-99%. During follow-up a period of 3-58 weeks (M 22 weeks), all stenosis were resolved without stent-related complications, and the general physical of all 15 patents was improved with no occurrence of obviously dyspnea and bleeding. Karnofsky performance status (KPS) was improved from preoperative 26%-45% to postoperative 72%-95%. Five patients died of the following causes unrelated to stent insertion: multiple organ failure (n=3), cachexia (n=1) and pulmonary infection caused by gastrobronehial fistula (n=1), and the remaining 10 patients were alive with no evidence of dyspnea at the time of this report. Conclusion: Deployment of the covered Y-shaped metallic stent with the use of Y metallic stent delivery system in the management of airway stenoses involving the lower trachea and the tracheal carina was a simple and safe procedure and with a good short-term clinical efficacy. (authors)

  20. CT coronary angiography: examination technique, clinical results, and outlook on future developments

    International Nuclear Information System (INIS)

    Dewey, M.; Hamm, B.

    2007-01-01

    Multislice computed tomography (MSCT) after intravenous contrast agent administration enables visualization of the coronary arteries with high spatial resolution (voxel sizes down to 0.5 x 0.35 x 0.35 mm3) and a short scan time. Magnetic resonance imaging (MRI) is also intensively studied with respect to the noninvasive detection of coronary artery stenosis and thus the detection of coronary artery disease (CAD) without radiation exposure but is not equal to MSCT at present. This article provides an overview of the historical development of CT coronary angiography from 4-slice CT to 16-slice CT and 64-slice CT. A crucial aspect of this development is the improvement in image quality resulting from shorter breath-hold periods and the reduced gantry rotation time. Other techniques that appear to considerably improve image quality and accuracy and make CT independent of patient heart rates are multisegment reconstruction and dual-source CT. Sublingual nitroglycerin as well as oral or intravenous betablocker administration should be considered in relation to the diagnostic question to be answered and the patient's heart rate. In the studies available CT coronary angiography with at least 12 simultaneous detector rows has a sensitivity of 96.9 % and a specificity of 75.3 % at the patient level. Especially the negative predictive value of CT (94.6 %) emphasizes the idea that this technique may reliably exclude CAD in patients with intermediate pretest likelihood. In the near future, 256-slice CT will allow examination of the entire heart during one heartbeat or even 4D CT scanning with simultaneous assessment of myocardial perfusion. Automatic or semiautomatic software tools will assume a central place in detecting and quantifying coronary artery stenoses and plaques as well as in the analysis of cardiac function in the clinical setting over the next years. Prior to its routine clinical use, the cost-effectiveness of CT coronary angiography must be determined and the

  1. Coronary artery anatomy and variants

    Energy Technology Data Exchange (ETDEWEB)

    Malago, Roberto; Pezzato, Andrea; Barbiani, Camilla; Alfonsi, Ugolino; Nicoli, Lisa; Caliari, Giuliana; Pozzi Mucelli, Roberto [Policlinico G.B. Rossi, University of Verona, Department of Radiology, Verona (Italy)

    2011-12-15

    Variants and congenital anomalies of the coronary arteries are usually asymptomatic, but may present with severe chest pain or cardiac arrest. The introduction of multidetector CT coronary angiography (MDCT-CA) allows the detection of significant coronary artery stenosis. Improved performance with isotropic spatial resolution and higher temporal resolution provides a valid alternative to conventional coronary angiography (CCA) in many patients. MDCT-CA is now considered the ideal tool for three-dimensional visualization of the complex and tortuous anatomy of the coronary arteries. With multiplanar and volume-rendered reconstructions, MDCT-CA may even outperform CCA in determining the relative position of vessels, thus providing a better view of the coronary vascular anatomy. The purpose of this review is to describe the normal anatomy of the coronary arteries and their main variants based on MDCT-CA with appropriate reconstructions. (orig.)

  2. [Pregnancy and coronary artery dissection].

    Science.gov (United States)

    Martínez-Quintana, Efrén; Rodríguez-González, Fayna

    2015-01-01

    Acute myocardial infarction during pregnancy is associated with high maternal and fetal mortality. Coronary atherosclerosis is the most common cause due to an increase in the age of the patients and the association with cardiovascular risk factors such as smoking, hypertension, diabetes mellitus, preeclampsia, and the existence of family history of coronary disease. However, thrombosis, coronary dissection or coronary vasospasms are other causes that may justify it. We report the case of a 33 weeks pregnant first-time mother, without cardiovascular risk factors, who presented an acute coronary event in the context of atherosclerotic disease and coronary dissection after percutaneous coronary intervention. Copyright © 2014 Sociedad Española de Arteriosclerosis. Published by Elsevier España. All rights reserved.

  3. Guyon's canal syndrome due to tortuous ulnar artery with DeQuervain stenosing tenosynovitis, ligamentous injuries and dorsal intercalated segmental instability syndrome, a rare presentation: a case report.

    Science.gov (United States)

    Zeeshan, Muhammad; Ahmed, Farhan; Kanwal, Darakhshan; Khalid, Qazi Saad Bin; Ahmed, Muhammad Nadeem

    2009-12-23

    The Guyon's canal syndrome is a well known clinical entity and may have significant impact on patient's quality of life. We report a case of 43-year-old male who presented with complaints of pain and numbness in right hand and difficulty in writing for past one month. On imaging diagnosis of Guyon's canal syndrome because of tortuous ulnar artery was made with additional findings of DeQuervain's stenosing tenosynovitis and dorsal intercalated segmental instability syndrome with ligamentous injury and subsequently these were confirmed on surgery.Although it is a rare syndrome, early diagnosis and treatment prevents permanent neurological deficits and improve patient's quality of life.

  4. X-ray micro computed tomography for the visualization of an atherosclerotic human coronary artery

    Science.gov (United States)

    Matviykiv, Sofiya; Buscema, Marzia; Deyhle, Hans; Pfohl, Thomas; Zumbuehl, Andreas; Saxer, Till; Müller, Bert

    2017-06-01

    Atherosclerosis refers to narrowing or blocking of blood vessels that can lead to a heart attack, chest pain or stroke. Constricted segments of diseased arteries exhibit considerably increased wall shear stress, compared to the healthy ones. One of the possibilities to improve patient’s treatment is the application of nano-therapeutic approaches, based on shear stress sensitive nano-containers. In order to tailor the chemical composition and subsequent physical properties of such liposomes, one has to know precisely the morphology of critically stenosed arteries at micrometre resolution. It is often obtained by means of histology, which has the drawback of offering only two-dimensional information. Additionally, it requires the artery to be decalcified before sectioning, which might lead to deformations within the tissue. Micro computed tomography (μCT) enables the three-dimensional (3D) visualization of soft and hard tissues at micrometre level. μCT allows lumen segmentation that is crucial for subsequent flow simulation analysis. In this communication, tomographic images of a human coronary artery before and after decalcification are qualitatively and quantitatively compared. We analyse the cross section of the diseased human coronary artery before and after decalcification, and calculate the lumen area of both samples.

  5. Ribose facilitates thallium-201 redistribution in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Perlmutter, N.S.; Wilson, R.A.; Angello, D.A.; Palac, R.T.; Lin, J.; Brown, B.G.

    1991-01-01

    To investigate whether i.v. infusion of ribose, an adenine nucleotide precursor, postischemia facilitates thallium-201 (201Tl) redistribution and improves identification of ischemic myocardium in patients with coronary artery disease (CAD), 17 patients underwent two exercise 201Tl stress tests, performed 1-2 wk apart. After immediate postexercise planar imaging, patients received either i.v. ribose (3.3 mg/kg/min x 30 min) or saline as a control. Additional imaging was performed 1 and 4 hr postexercise. Reversible defects were identified by count-profile analysis. Significantly more (nearly twice as many) reversible 201Tl defects were identified on the post-ribose images compared to the post-saline (control) images at both 1 and 4 hr postexercise (p less than 0.001). Quantitative analyses of the coronary arteriogram was available in 13 patients and confirmed that the additional reversible defects were in myocardial regions supplied by stenosed arteries. We conclude that ribose appears to facilitate 201Tl redistribution in patients with CAD and enhances identification of ischemic myocardium

  6. Improved left ventricular function and perfusion at rest after successful transluminal coronary angioplasty

    International Nuclear Information System (INIS)

    Klepzig, H.; Kaltenbach, M.; Standke, R.; Maul, F.D.; Hoer, G.

    1991-01-01

    The purpose of this study was to evaluate left ventricular function and perfusion at rest before and after percutaneous transluminal coronary angioplasty. In consecutive 69 patients in whom coronary stenoses were dilated, the radionuclide left ventricular ejection fraction at rest increased significantly. In 26 of these patients, the ejection fraction increased by at least 4%. In these patients, exercise-induced ischemic ST depression had been more pronounced than in the others. 36 other patients underwent 201 Tl myocardial scintigraphy before and after angioplasty. Twelve patients in whom pre-PTCA images had revealed regions with irreversible 201 Tl uptake defects, showed normal 201 Tl distribution patterns on post-PTCA scintigrams. Post-exercise 201 Tl uptake (representing myocardial perfusion and metabolic activity) during pre-PTCA exercise stress tests was significantly lower in these cases. It is concluded that PTCA can improve left ventricular function and perfusion at rest. This improvement is most obvious in patients with pronounced exercise-induced myocardial ischemia as diagnosed by typical ST segment depression and reduced thallium uptake. (orig.) [de

  7. Good cell culture practices &in vitro toxicology.

    Science.gov (United States)

    Eskes, Chantra; Boström, Ann-Charlotte; Bowe, Gerhard; Coecke, Sandra; Hartung, Thomas; Hendriks, Giel; Pamies, David; Piton, Alain; Rovida, Costanza

    2017-12-01

    Good Cell Culture Practices (GCCP) is of high relevance to in vitro toxicology. The European Society of Toxicology In Vitro (ESTIV), the Center for Alternatives for Animal Testing (CAAT) and the In Vitro Toxicology Industrial Platform (IVTIP) joined forces to address by means of an ESTIV 2016 pre-congress session the different aspects and applications of GCCP. The covered aspects comprised the current status of the OECD guidance document on Good In Vitro Method Practices, the importance of quality assurance for new technological advances in in vitro toxicology including stem cells, and the optimized implementation of Good Manufacturing Practices and Good Laboratory Practices for regulatory testing purposes. General discussions raised the duality related to the difficulties in implementing GCCP in an academic innovative research framework on one hand, and on the other hand, the need for such GCCP principles in order to ensure reproducibility and robustness of in vitro test methods for toxicity testing. Indeed, if good cell culture principles are critical to take into consideration for all uses of in vitro test methods for toxicity testing, the level of application of such principles may depend on the stage of development of the test method as well as on the applications of the test methods, i.e., academic innovative research vs. regulatory standardized test method. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. In vitro anticoagulation monitoring of low-molecular-weight heparin

    Institute of Scientific and Technical Information of China (English)

    WANG Jian-qi; SHI Xu-bo; YANG Jin-gang; HU Da-yi

    2009-01-01

    Background Although low-molecular-weight heparin has replaced unfractionated heparin to become the primary anticoagulation drug for treatment of acute coronary syndrome, there is no convenient bedside monitoring method. We explored the best laboratory monitoring method of low-molecular-weight heparins (enoxapadn, dalteparin, and nadroparin) by use of the Sonoclot coagulation analyzer to monitor the activated clotting time.Methods Atotal of 20 healthy volunteers were selected and 15 ml of fasting venous blood samples were collected and incubated. Four coagulants, kaolin, diatomite, glass bead, and magnetic stick, were used to determine the activated clotting time of the low-molecular-weight heparins at different in vitro anti-Xa factor concentrations. A correlation analysis was made to obtain the regression equation. The activated clotting time of the different low-molecular-weight heparins with the same anti-Xa factor concentration was monitored when the coagulant glass beads were applied. Results The activated clotting time measured using the glass beads, diatomite, kaolin, and magnetic stick showed a linear correlation with the concentration of nadroparin (r= 0.964, 0.966, 0.970, and 0.947, respectively). The regression equation showed that the linear slopes of different coagulants were significantly different (glass beads 230.03 s/IU,diatomite 89.91 s/IU, kaolin 50.87 s/IU, magnetic stick could not be calculated). When the concentration of the anti-Xa factor was the same for different low-molecular-weight heparins, the measured activated clotting time was different after the application of the glass bead coagulant.Conclusions The glass bead coagulant is most feasible for monitoring the in vitro anticoagulation activity of nadroparin.The different effects of different low-molecular-weight heparins on the activated clotting time may be related to the different anti-Ila activities.

  9. Prospective and retrospective ECG-gating for CT coronary angiography perform similarly accurate at low heart rates

    Energy Technology Data Exchange (ETDEWEB)

    Stolzmann, Paul, E-mail: paul.stolzmann@usz.ch [Institute of Diagnostic Radiology, University Hospital Zurich, Raemistrasse 100, 8091 Zurich (Switzerland); Goetti, Robert; Baumueller, Stephan [Institute of Diagnostic Radiology, University Hospital Zurich, Raemistrasse 100, 8091 Zurich (Switzerland); Plass, Andre; Falk, Volkmar [Clinic for Cardiovascular Surgery, University Hospital Zurich (Switzerland); Scheffel, Hans; Feuchtner, Gudrun; Marincek, Borut [Institute of Diagnostic Radiology, University Hospital Zurich, Raemistrasse 100, 8091 Zurich (Switzerland); Alkadhi, Hatem [Institute of Diagnostic Radiology, University Hospital Zurich, Raemistrasse 100, 8091 Zurich (Switzerland); Cardiac MR PET CT Program, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Leschka, Sebastian [Institute of Diagnostic Radiology, University Hospital Zurich, Raemistrasse 100, 8091 Zurich (Switzerland)

    2011-07-15

    Objective: To compare, in patients with suspicion of coronary artery disease (CAD) and low heart rates, image quality, diagnostic performance, and radiation dose values of prospectively and retrospectively electrocardiography (ECG)-gated dual-source computed tomography coronary angiography (CTCA) for the diagnosis of significant coronary stenoses. Materials and methods: Two-hundred consecutive patients with heart rates {<=}70 bpm were retrospectively enrolled; 100 patients undergoing prospectively ECG-gated CTCA (group 1) and 100 patients undergoing retrospectively-gated CTCA (group 2). Coronary artery segments were assessed for image quality and significant luminal diameter narrowing. Sensitivity, specificity, positive predictive values (PPV), negative predictive values (NPV), and accuracy of both CTCA groups were determined using conventional catheter angiography (CCA) as reference standard. Radiation dose values were calculated. Results: Both groups were comparable regarding gender, body weight, cardiovascular risk profile, severity of CAD, mean heart rate, heart rate variability, and Agatston score (all p > 0.05). There was no significant difference in the rate of non-assessable coronary segments between group 1 (1.6%, 24/1404) and group 2 (1.4%, 19/1385; p = 0.77); non-diagnostic image quality was significantly (p < 0.001) more often attributed to stair step artifacts in group 1. Segment-based sensitivity, specificity, PPV, NPV, and accuracy were 98%, 98%, 88%, 100%, and 100% among group 1; 96%, 99%, 90%, 100%, and 98% among group 2, respectively. Parameters of diagnostic performance were similar (all p > 0.05). Mean effective radiation dose of prospectively ECG-gated CTCA (2.2 {+-} 0.4 mSv) was significantly (p < 0.0001) smaller than that of retrospectively ECG-gated CTCA (8.1 {+-} 0.6 mSv). Conclusion: Prospectively ECG-gated CTCA yields similar image quality, performs as accurately as retrospectively ECG-gated CTCA in patients having heart rates {<=}70 bpm

  10. Quantification of the myocardial area at risk using coronary CT angiography and Voronoi algorithm-based myocardial segmentation

    Energy Technology Data Exchange (ETDEWEB)

    Kurata, Akira; Kono, Atsushi; Coenen, Adriaan; Saru-Chelu, Raluca G.; Krestin, Gabriel P. [Erasmus University Medical Center, Department of Radiology, Rotterdam (Netherlands); Sakamoto, Tsuyoshi [AZE inc, Development Division, Chiyoda, Tokyo (Japan); Kido, Teruhito; Mochizuki, Teruhito [Ehime University Graduate School of Medicine, Department of Radiology, Toon, Ehime (Japan); Higashino, Hiroshi [Yotsuba Circulation Clinic, Department of Radiology, Matsuyama, Ehime (Japan); Abe, Mitsunori [Yotsuba Circulation Clinic, Department of Cardiology, Matsuyama, Ehime (Japan); Feyter, Pim J. de; Nieman, Koen [Erasmus University Medical Center, Department of Radiology, Rotterdam (Netherlands); Erasmus University Medical Center, Department of Cardiology, Rotterdam (Netherlands)

    2015-01-15

    The purpose of this study was to estimate the myocardial area at risk (MAAR) using coronary computed tomography angiography (CTA) and Voronoi algorithm-based myocardial segmentation in comparison with single-photon emission computed tomography (SPECT). Thirty-four patients with coronary artery disease underwent 128-slice coronary CTA, stress/rest thallium-201 SPECT, and coronary angiography (CAG). CTA-based MAAR was defined as the sum of all CAG stenosis (>50 %) related territories (the ratio of the left ventricular volume). Using automated quantification software (17-segment model, 5-point scale), SPECT-based MAAR was defined as the number of segments with a score above zero as compared to the total 17 segments by summed stress score (SSS), difference (SDS) score map, and comprehensive SPECT interpretation with either SSS or SDS best correlating CAG findings (SSS/SDS). Results were compared using Pearson's correlation coefficient. Forty-nine stenoses were observed in 102 major coronary territories. Mean value of CTA-based MAAR was 28.3 ± 14.0 %. SSS-based, SDS-based, and SSS/SDS-based MAAR was 30.1 ± 6.1 %, 20.1 ± 15.8 %, and 26.8 ± 15.7 %, respectively. CTA-based MAAR was significantly related to SPECT-based MAAR (r = 0.531 for SSS; r = 0.494 for SDS; r = 0.814 for SSS/SDS; P < 0.05 in each). CTA-based Voronoi algorithm myocardial segmentation reliably quantifies SPECT-based MAAR. (orig.)

  11. Quantification of the myocardial area at risk using coronary CT angiography and Voronoi algorithm-based myocardial segmentation

    International Nuclear Information System (INIS)

    Kurata, Akira; Kono, Atsushi; Coenen, Adriaan; Saru-Chelu, Raluca G.; Krestin, Gabriel P.; Sakamoto, Tsuyoshi; Kido, Teruhito; Mochizuki, Teruhito; Higashino, Hiroshi; Abe, Mitsunori; Feyter, Pim J. de; Nieman, Koen

    2015-01-01

    The purpose of this study was to estimate the myocardial area at risk (MAAR) using coronary computed tomography angiography (CTA) and Voronoi algorithm-based myocardial segmentation in comparison with single-photon emission computed tomography (SPECT). Thirty-four patients with coronary artery disease underwent 128-slice coronary CTA, stress/rest thallium-201 SPECT, and coronary angiography (CAG). CTA-based MAAR was defined as the sum of all CAG stenosis (>50 %) related territories (the ratio of the left ventricular volume). Using automated quantification software (17-segment model, 5-point scale), SPECT-based MAAR was defined as the number of segments with a score above zero as compared to the total 17 segments by summed stress score (SSS), difference (SDS) score map, and comprehensive SPECT interpretation with either SSS or SDS best correlating CAG findings (SSS/SDS). Results were compared using Pearson's correlation coefficient. Forty-nine stenoses were observed in 102 major coronary territories. Mean value of CTA-based MAAR was 28.3 ± 14.0 %. SSS-based, SDS-based, and SSS/SDS-based MAAR was 30.1 ± 6.1 %, 20.1 ± 15.8 %, and 26.8 ± 15.7 %, respectively. CTA-based MAAR was significantly related to SPECT-based MAAR (r = 0.531 for SSS; r = 0.494 for SDS; r = 0.814 for SSS/SDS; P < 0.05 in each). CTA-based Voronoi algorithm myocardial segmentation reliably quantifies SPECT-based MAAR. (orig.)

  12. Pooled comparison of regadenoson versus adenosine for measuring fractional flow reserve and coronary flow in the catheterization laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Stolker, Joshua M., E-mail: jstolker@yahoo.com [Mercy Heart and Vascular, 901 Patients First Drive, Washington, MO 63090 (United States); Saint Louis University, 3635 Vista Ave, St. Louis, MO 63110 (United States); Lim, Michael J., E-mail: limmj@slu.edu [Saint Louis University, 3635 Vista Ave, St. Louis, MO 63110 (United States); Shavelle, David M., E-mail: david.shavelle@med.usc.edu [University of Southern California, 1510 San Pablo St, Suite 322, Los Angeles, CA 90033 (United States); Morris, D. Lynn, E-mail: morrisdl@einstein.edu [Albert Einstein Medical Center, 5501 Old York Rd, Philadelphia, PA 19141 (United States); Angiolillo, Dominick J., E-mail: dominick.angiolillo@jax.ufl.edu [University of Florida Health-Jacksonville, 655 West 8th St, Jacksonville, FL 32209 (United States); Guzman, Luis A., E-mail: luis.guzman@jax.ufl.edu [University of Florida Health-Jacksonville, 655 West 8th St, Jacksonville, FL 32209 (United States); Kennedy, Kevin F., E-mail: kfkennedy@saint-lukes.org [Saint Luke' s Mid America Heart Institute, 4401 Wornall Road, Kansas City, MO 64111 (United States); Weber, Elizabeth, E-mail: eweber1@slu.edu [Saint Louis University, 3635 Vista Ave, St. Louis, MO 63110 (United States); Zareh, Meena, E-mail: meena.zareh@med.usc.edu [University of Southern California, 1510 San Pablo St, Suite 322, Los Angeles, CA 90033 (United States); Neumayr, Robert H., E-mail: robneumayr@gmail.com [Mercy Heart and Vascular, 901 Patients First Drive, Washington, MO 63090 (United States); Saint Louis University, 3635 Vista Ave, St. Louis, MO 63110 (United States); Zenni, Martin M., E-mail: martin.zenni@jax.ufl.edu [University of Florida Health-Jacksonville, 655 West 8th St, Jacksonville, FL 32209 (United States)

    2015-07-15

    Background: Adenosine is the gold standard for augmenting coronary flow during fractional flow reserve (FFR) testing of intermediate coronary stenoses. However, intravenous infusion is time-consuming and intracoronary injection is subject to variability. Regadenoson is a newer adenosine alternative administered as a single intravenous bolus during nuclear stress testing, but its efficacy and safety during FFR testing have been evaluated only in small, single-center studies. Methods: We pooled data from 5 academic hospitals, in which patients undergoing clinically-indicated FFR prospectively underwent comparison of intravenous adenosine infusion (140–175 mcg/kg/min) versus regadenoson bolus (400 mcg). Hemodynamics and symptoms with adenosine were recorded until maximal hyperemia occurred, and after returning to baseline hemodynamics, regadenoson was administered and monitoring was repeated. In a subset of patients with coronary flow data, average peak velocity (APV) at the distal flow sensor was recorded. Results: Of 149 patients enrolled, mean age was 59 ± 9 years, 76% were male, and 54% underwent testing of the left anterior descending artery. Mean adenosine-FFR and regadenoson-FFR were identical (0.82 ± 0.10) with excellent correlation of individual values (r = 0.96, p < 0.001) and no difference in patient-reported symptoms. Four patients (2.6%) had discrepancies between the 2 drugs for the clinical decision-making cutoff of FFR ≤ 0.80. Coronary flow responses to adenosine and regadenoson were similar (APV at maximal hyperemia 36 cm/s for both, p = 0.81). Conclusions: Regadenoson single-bolus administration has comparable FFR, symptoms, and coronary flow augmentation when compared with standard intravenous adenosine infusion. With its greater ease of administration, regadenoson may be a more “user-friendly” option for invasive ischemic testing.

  13. Quantitative myocardial perfusion PET combined with coronary anatomy derived from CT angiography. Validation of a new fusion and visualisation software

    International Nuclear Information System (INIS)

    Fricke, Harald; Weise, Reiner; Burchert, Wolfgang; Fricke, Eva; Elsner, Andreas; Bolte, Matthias; Domik, Gitta; Hoff, Joerg van den

    2009-01-01

    Aim: Dynamic perfusion PET offers a clinical relevant advantage over myocardial perfusion scintigraphy due to its ability to measure myocardial blood flow quantitatively. This leads to an improved detection of multivessel disease and the possibility to assess not only the culprit lesion but lower grade stenoses as well. For appropriate revascularization, perfusion defects must be matched to coronary lesions. It has been shown that image fusion of morphological and functional images is superior to side-by-side analysis. Still, software for quantitative perfusion PET combined with CT angiography is rare. In this paper we present a new software tool for image fusion and visualization of quantitative perfusion PET and coronary morphology derived from CT angiography. Methods: In our software, a PET uptake image is used for manual co-registration. Co-registration results are then applied to the functional data derived from compartment modelling. To evaluate the reproducibility of the manual co-registration, we calculated the deviation between a series of manual co-registrations performed on nine pairs of unregistered PET and CT datasets by five trained participants. Two dimensional transfer functions were used to highlight the coronary arteries from the CT study in the combined data sets. Results: The average Euclidian distances for three references points were between 3.7 and 4.1 mm. The maximum distance was 10.6 mm. By the use of the two dimensional transfer functions, coronary anatomy could be easily visualised either by user-interaction or automatically by use of neuronal networks. Conclusions: With this approach it is possible to combine quantitative perfusion PET with coronary anatomy derived from CT angiography. Our first experiences indicate that manual image fusion with our tool is reproducible and that visualisation of the combined datasets is achieved within short time. (orig.)

  14. Coronary CT Angiography in the Quantitative Assessment of Coronary Plaques

    Directory of Open Access Journals (Sweden)

    Zhonghua Sun

    2014-01-01

    Full Text Available Coronary computed tomography angiography (CCTA has been recently evaluated for its ability to assess coronary plaque characteristics, including plaque composition. Identification of the relationship between plaque composition by CCTA and patient clinical presentations may provide insight into the pathophysiology of coronary artery plaque, thus assisting identification of vulnerable plaques which are associated with the development of acute coronary syndrome. CCTA-generated 3D visualizations allow evaluation of both coronary lesions and lumen changes, which are considered to enhance the diagnostic performance of CCTA. The purpose of this review is to discuss the recent developments that have occurred in the field of CCTA with regard to its diagnostic accuracy in the quantitative assessment of coronary plaques, with a focus on the characterization of plaque components and identification of vulnerable plaques.

  15. Assessment of myocardial blood flow and coronary flow reserve with positron emission tomography in ischemic heart disease: current state and future directions.

    Science.gov (United States)

    Al Badarin, Firas; Aljizeeri, Ahmed; Almasoudi, Fatimah; Al-Mallah, Mouaz H

    2017-07-01

    Positron emission tomography (PET) is a versatile imaging technology that allows assessment of myocardial perfusion, both at a spatially relative scale and also in absolute terms, thereby enabling noninvasive evaluation of myocardial blood flow (MBF) and coronary flow reserve (CFR). Assessment of MBF using FDA-approved PET isotopes, such as 82 Rb and 13 N-ammonia, has been well validated, and several software packages are currently available, thereby allowing for MBF evaluation to be incorporated into routine workflow in contemporary nuclear laboratories. Incremental diagnostic and prognostic information provided with the knowledge of MBF has the potential for widespread applications. Improving the ability to identify the true burden of obstructive epicardial coronary stenoses and allowing for noninvasive assessment of coronary micro circulatory function can be achieved with MBF assessment. On the other hand, attenuated CFR has been shown to predict adverse cardiovascular prognosis in a variety of clinical settings and patient subgroups. With expanding applications of MBF, this tool promises to provide unique insight into the integrity of the entire coronary vascular bed beyond what is currently available with relative perfusion assessment. This review intends to provide an in-depth discussion of technical and clinical aspects of MBF assessment with PET as it relates to patients with ischemic heart disease.

  16. Trigger Finger (Stenosing Tenosynovitis)

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is a Hand Surgeon? What is a Hand Therapist? Media Find a Hand Surgeon Home Anatomy Trigger Finger Email to a friend * required fields ...

  17. [Peculiarities of the course of arterial hypertension in patients with atherosclerotic stenoses of brachiocephalic arteries before and after surgery on carotid arteries].

    Science.gov (United States)

    Kosacheva, N B; Tuev, A V

    2013-01-01

    Study aim was to investigate relationship between atherosclerosis of carotid arteries (CA) and the presence of arterial hypertension (AH) and possibilities of correction of AH after surgery. We examined 70 patients with episodes of elevation of arterial pressure (AP) scheduled for surgical interventions on brachiocephalic arteries (BCA) because of CA stenoses (n=50, group 1) or anomalies of BCA development (n=20, group 2). Before operation patients of group 1 had higher mean AP than patients of group 2 (103.6+/-11.3 and 91.7+/-6.6 mm Hg, respectively, p=0.00007). This difference disappeared after surgery. In postoperative period in patients with CA stenoses levels of both systolic and diastolic AP decreased (from 145.1+/-14.7 to 135.6+/-12.3, p=0.02; and from 83.3+/-10.2 78.1+/-9.7 mm Hg, =0.02, respectively). In group 2 no significant AP reduction was observed. Thus AP elevation in patients with involvement of BCA to a considerable degree is caused by CA stenosis. Surgical treatment of these patients facilitates lowering of AP.

  18. Phytochemical screening and in vitro acetylcholinesterase inhibitory ...

    African Journals Online (AJOL)

    Phytochemical screening and in vitro acetylcholinesterase inhibitory activity of seven plant extracts. Titilayo Johnson, Oduje A. Akinsanmi, Enoch J. Banbilbwa, Tijani A. Yahaya, Karima Abdulaziz, Kolade Omole ...

  19. The Ethics of Producing In Vitro Meat.

    Science.gov (United States)

    Schaefer, G Owen; Savulescu, Julian

    2014-05-01

    The prospect of consumable meat produced in a laboratory setting without the need to raise and slaughter animals is both realistic and exciting. Not only could such in vitro meat become popular due to potential cost savings, but it also avoids many of the ethical and environmental problems with traditional meat productions. However, as with any new technology, in vitro meat is likely to face some detractors. We examine in detail three potential objections: 1) in vitro meat is disrespectful, either to nature or to animals; 2) it will reduce the number of happy animals in the world; and 3) it will open the door to cannibalism. While each objection has some attraction, we ultimately find that all can be overcome. The upshot is that in vitro meat production is generally permissible and, especially for ethical vegetarians, worth promoting.

  20. In-vitro-measuring in nuclear medicine

    International Nuclear Information System (INIS)

    Berthold, F.

    1976-01-01

    The latest developments in in-vitro measuring are in the fields of sample preparation and data processing. They help to arrive at integrated systems enabling an almost complete automation, especially of radioimmunoassays. (orig.) [de

  1. Tetrabromobisphenol A In vitro Dermal Absopriton Data

    Data.gov (United States)

    U.S. Environmental Protection Agency — In vitro dermal absorption data of tetrabromobisphenol A using human cadaver and rat skin. This dataset is associated with the following publication: Knudsen, G., M....

  2. Proliferation and extracellular matrix synthesis of smooth muscle cells cultured from human coronary atherosclerotic and restenotic lesions

    NARCIS (Netherlands)

    D.C. MacLeod (Donald); B.H. Strauss (Bradley); J. Escaned (Javier); V.A.W.M. Umans (Victor); R-J. van Suylen (Robert-Jan); A. Verkerk (Anton); P.J. de Feyter (Pim); P.W.J.C. Serruys (Patrick); M. de Jong (Marcel)

    1994-01-01

    textabstractOBJECTIVES. The purpose of this study was to examine the proliferative capacity and extracellular matrix synthesis of human coronary plaque cells in vitro. BACKGROUND. Common to both primary atherosclerosis and restenosis are vascular smooth muscle cell proliferation and production of

  3. Percutaneous transluminal coronary angioplasty

    International Nuclear Information System (INIS)

    Przybojewski, J.Z.; Weich, H.F.H.

    1984-01-01

    The purpose of this article is to review PTCA, percutaneous transluminal coronary angioplasty, which can be considered to be a truly revolutionary and fairly simple invasive form of intervention to atherosclerotic obstruction. The 'epidemic' of IHD, ischaemic heart disease, in the Republic of South Africa calls for the employment of this technique, which has already been carried out in a few teaching hospitals in this country. Very recently, modified balloon dilatation catheters have been used percutaneously in the non-operative transluminal correction of congenital coarctation of the aorta in infants and children, congenital pulmonary value stenosis, and hypoplasia and stenosis of the pulmonary arteries. It has also been employed for PTCA and for the simultaneous occlusion of coronary-bronchial artery anastomosis using a detachable balloon. The isotopes thallium 201 and technetium 99 were also used in scintiscanning

  4. Feasibility and Diagnostic Accuracy of Whole Heart Coronary MR Angiography Using Free-Breathing 3D Balanced Turbo-Field-Echo with SENSE and the Half-Fourier Acquisition Technique

    International Nuclear Information System (INIS)

    Kim, Young Jin; Seo, Jae Seung; Choi, Byoung Wook; Choe, Kyu Ok; Jang, Yang Soo; Ko, Young Guk

    2006-01-01

    We wanted to assess the feasibility and diagnostic accuracy of whole heart coronary magnetic resonance angiography (MRA) with using 3D balanced turbo-field-echo (b-TFE) with SENSE and the half-Fourier acquisition technique for identifying stenoses of the coronary artery. Twenty-one patients who underwent both whole heart coronary MRA examinations and conventional catheter coronary angiography examinations were enrolled in the study. The whole heart coronary MRA images were acquired using a navigator gated 3D b-TFE sequence with SENSE and the half-Fourier acquisition technique to reduce the acquisition time. The imaging slab covered the whole heart (80 contiguous slices with a reconstructed slice thickness of 1.5 mm) along the transverse axis. The quality of the images was evaluated by using a 5-point scale (0 - uninterpretable, 1 - poor, 2 - fair, 3 - good, 4 - excellent). Ten coronary segments of the heart were evaluated in each case; the left main coronary artery (LM), and the proximal, middle and distal segments of the left anterior descending (LAD), the left circumflex (LCX) and the right coronary artery (RCA). The diagnostic accuracy of whole heart coronary MRA for detecting significant coronary artery stenosis was determined on the segment-bysegment basis, and it was compared with the results obtained by conventional catheter angiography, which is the gold standard. The mean image quality was 3.7 in the LM, 3.2 in the LAD, 2.5 in the LCX, and 3.3 in the RCA, respectively (the overall image quality was 3.0 ± 0.1). 168 (84%) of the 201 segments had an acceptable image quality (≥ grade 2). The sensitivity, specificity, accuracy, negative predictive value and positive predictive value of the whole heart coronary MRA images for detecting significant stenosis were 81.3%, 92.1%, 91.1%, 97.9%, and 52.0%, respectively. The mean coronary MRA acquisition time was 9 min 22 sec (± 125 sec). Whole heart coronary MRA is a feasible technique, and it has good potential to

  5. Meniscotibial (coronary) ligament tears

    International Nuclear Information System (INIS)

    El-Khoury, G.Y.; Usta, H.Y.; Berger, R.A.

    1984-01-01

    Preservation of the meniscus whenever possible is essential in maintaining knee stability and preventing premature osteoarthritis. Peripheral meniscal tears are the most amenable to surgical repair. This study evaluates the peripheral attachments of the medial meniscus and focuses on a specific tear limited to the meniscotibial ligament (coronary ligament). The diagnosis is made arthrographically when the medial meniscus floats above the tibial plateau without separating completely from the capsule. The lateral meniscus is rarely involved in this type of injury. (orig.)

  6. Comparative assessment of image quality for coronary CT angiography with iobitridol and two contrast agents with higher iodine concentrations: iopromide and iomeprol. A multicentre randomized double-blind trial

    Energy Technology Data Exchange (ETDEWEB)

    Achenbach, Stephan [Friedrich-Alexander-Universitaet Erlangen-Nuernberg, Department of Cardiology, Erlangen (Germany); Paul, Jean-Francois [Centre Chirurgical Marie Lannelongue, Department of Radiology, Le Plessis Robinson (France); Laurent, Francois [University of Bordeaux, Centre de Recherche Cardio-Thoracique de Bordeaux, U1045, Bordeaux (France); CHU de Bordeaux, Service d' Imagerie Thoracique et Cardiovasculaire, Pessac (France); Becker, Hans-Christoph [University Hospital Grosshadern, Department of Clinical Radiology, Munich (Germany); Rengo, Marco [Sapienza - University of Rome, ICOT Hospital, Department of Radiological Sciences, Oncology and Pathology, Latina (Italy); Caudron, Jerome [University Hospital of Rouen, Department of Radiology, Rouen (France); Leschka, Sebastian [Saint Gallen Hospital, Department of Radiology, Saint Gallen (Switzerland); Vignaux, Olivier [Cochin Hospital, Department of Radiology, Paris (France); Knobloch, Gesine [La Charite, Department of Radiology, Berlin (Germany); Benea, Giorgio [Ospedale del Delta, Ferrara (Italy); Schlosser, Thomas [Elisabeth-Krankenhaus Hospital, Essen (Germany); Andreu, Jordi [Hospital Vall d' Hebron, Barcelona (Spain); Cabeza, Beatriz [Hospital Clinico San Carlos, Madrid (Spain); Jacquier, Alexis [La Timone Adult Hospital, Department of Radiology, Marseille (France); Souto, Miguel [Complejo Hospitalario Universitario, Santiago de Compostela (Spain); Revel, Didier [Louis Pradel Hospital, Department of Radiology, Lyon (France); Qanadli, Salah Dine [University of Lausanne, Department of Radiology, Lausanne (Switzerland); Cademartiri, Filippo [Giovanni XXIII Hospital, Department of Radiology, Monastier di Treviso (Italy); Collaboration: X-ACT Study Group

    2017-02-15

    To demonstrate non-inferiority of iobitridol 350 for coronary CT angiography (CTA) compared to higher iodine content contrast media regarding rate of patients evaluable for the presence of coronary artery stenoses. In this multicentre trial, 452 patients were randomized to receive iobitridol 350, iopromide 370 or iomeprol 400 and underwent coronary CTA using CT systems with 64-detector rows or more. Two core lab readers assessed 18 coronary segments per patient regarding image quality (score 0 = non diagnostic to 4 = excellent quality), vascular attenuation, signal and contrast to noise ratio (SNR, CNR). Patients were considered evaluable if no segment had a score of 0. Per-patient, the rate of fully evaluable CT scans was 92.1, 95.4 and 94.6 % for iobitridol, iopromide and iomeprol, respectively. Non-inferiority of iobitridol over the best comparator was demonstrated with a 95 % CI of the difference of [-8.8 to 2.1], with a pre-specified non-inferiority margin of -10 %. Although average attenuation increased with higher iodine concentrations, average SNR and CNR did not differ between groups. With current CT technology, iobitridol 350 mg iodine/ml is not inferior to contrast media with higher iodine concentrations in terms of image quality for coronary stenosis assessment. (orig.)

  7. Results of in vitro chemosensitivity assays

    International Nuclear Information System (INIS)

    Tanigawa, Nobuhiko; Morimoto, Hideki; Akita, Toshiaki; Inoue, Hiroshi; Tanaka, Takeo.

    1986-01-01

    The authors reviewed their experiences to date with chemosensitivity testing of 629 tumors by human tumor clonogenic assay (HTCA) and of 199 tumors by scintillation assay (SA). HTCA and SA were both performed using a double-layer-soft-agar system with continuous exposure of cells to one concentration of standard anticancer drugs. Overall, 60 % of specimens in HTCA and 58 % in SA produced significant growth in vitro. HTCA was 52 % (13/25) reliable for predicting in vivo sensitivity, and 95 % (36/38) reliable for in vivo resistance, whereas SA was 40 % (8/20) reliable for in vivo sensitivity and 88 % (21/24) for in vivo resistance. In vitro success rates were variable, depending on the tumor histology. In vitro growth of gastric cancer specimens was characteristically lower than that of colon cancer specimens (48 % and 60 % in HTCA, and 46 % and 68 % in SA, respectively). (p < 0.005). Optimal in vitro-in vivo drug concentrations and culture conditions are still being defined. Correlation studies of in vitro-in vivo responses of gastrointestinal cancers suggested that in vitro concentrations of 5-fluorouracil and mitomycin C used in this study were considerably higher than their optimal doses. Tumor cell heterogeneity poses significant problems in the clinical use of chemosensitivity assays. In this last study, we sought evidence of tumor heterogeneity by comparing chemosensitivity responses between : 1) different portions of a single tumor, 2) a primary and a metastatic biopsy taken from a patient on the same day, and 3) different metastases from a patient taken on the same day. The results demonstrated the presence of considerable heterogeneity of response to chemotherapy among different tumors from the same patient, and even within the same tumor. The reported discrepancies of in vitro and in vivo sensitivity may be due to such therapeutic heterogeneity among tumors. (J.P.N.)

  8. Coffee consumption and coronary calcification - The Rotterdam Coronary Calcification Study

    NARCIS (Netherlands)

    van Woudenbergh, Geertruida J.; Vliegenthart, Rozemarijn; van Rooij, Frank J. A.; Hofman, Albert; Oudkerk, Matthijs; Witteman, Jacqueline C. M.; Geleijnse, Johanna M.

    Background-The role of coffee in the cardiovascular system is not yet clear. We examined the relation of coffee intake with coronary calcification in a population-based cohort. Methods and Results-The study involved 1570 older men and women without coronary heart disease who participated in the

  9. Coffee consumption and coronary calcification: The Rotterdam coronary calcification study

    NARCIS (Netherlands)

    G.J. van Woudenbergh (Geertruida); R. Vliegenthart (Rozemarijn); F.J.A. van Rooij (Frank); A. Hofman (Albert); M. Oudkerk (Matthijs); J.C.M. Witteman (Jacqueline); J.M. Geleijnse (Marianne)

    2008-01-01

    textabstractBACKGROUND - The role of coffee in the cardiovascular system is not yet clear. We examined the relation of coffee intake with coronary calcification in a population-based cohort. METHODS AND RESULTS - The study involved 1570 older men and women without coronary heart disease who

  10. Coffee Consumption and Coronary Calcification: The Rotterdam Coronary Calcification Study

    NARCIS (Netherlands)

    Woudenbergh, van G.J.; Vliegenthart, R.; Rooij, van F.J.A.; Hofman, A.; Oudkerk, M.; Witteman, J.C.M.; Geleijnse, J.M.

    2008-01-01

    Background¿ The role of coffee in the cardiovascular system is not yet clear. We examined the relation of coffee intake with coronary calcification in a population-based cohort. Methods and Results¿ The study involved 1570 older men and women without coronary heart disease who participated in the

  11. Systemic inflammation is higher in peripheral artery disease than in stable coronary artery disease.

    Science.gov (United States)

    Rein, Philipp; Saely, Christoph H; Silbernagel, Günther; Vonbank, Alexander; Mathies, Rainer; Drexel, Heinz; Baumgartner, Iris

    2015-04-01

    The knowledge on the level of systemic inflammation in peripheral artery disease (PAD) is less well established than that in coronary artery disease (CAD). Systemic inflammation frequently coincides with atherosclerosis, but also with various traits of the metabolic syndrome (MetS). The individual contribution of CAD, PAD, and the MetS to inflammation is not known. We enrolled a total of 1396 patients, 460 patients with PAD Fontaine stages IIa-IV verified by duplex ultrasound (PAD group) and 936 patients free of limb claudication undergoing coronary angiography, of whom 507 had significant CAD with coronary stenoses ≥50% (CAD group), and 429 did not have significant CAD at angiography (control group). C-reactive protein (CRP) was significantly higher in the PAD than in the CAD or in the control group (0.86 ± 1.85 mg/dl versus 0.44 ± 0.87 mg/dl and 0.39 ± 0.52 mg/dl, respectively, p < 0.001 for both comparisons). These significant differences were confirmed when patients with and subjects without the MetS were analyzed separately. In particular, within the PAD group, CRP was significantly higher in patients with the MetS than in subjects without the MetS (1.04 ± 2.01 vs. 0.67 ± 1.64 mg/dl; p = 0.001) and both, the presence of PAD and the MetS proved to be independently associated with CRP in analysis of covariance (F = 31.84; p < 0.001 and F = 10.52; p = 0.001, respectively). Inflammatory activity in PAD patients is higher than in CAD patients and is particularly high in PAD patients affected by the MetS. Low grade systemic inflammation is independently associated with both the MetS and PAD. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  12. Results of completion arteriography after minimally invasive off-pump coronary artery bypass.

    Science.gov (United States)

    Hoff, Steven J; Ball, Stephen K; Leacche, Marzia; Solenkova, Natalia; Umakanthan, Ramanan; Petracek, Michael R; Ahmad, Rashid; Greelish, James P; Walker, Kristie; Byrne, John G

    2011-01-01

    The benefits of a minimally invasive approach to off-pump coronary artery bypass remain controversial. The value of completion arteriography in validating this technique has not been investigated. From April 2007 to October 2009, fifty-six patients underwent isolated minimally invasive coronary artery bypass grafting through a left thoracotomy without cardiopulmonary bypass. Forty-three of these patients underwent completion arteriography. Sixty-five grafts were performed in these 56 patients, (average, 1.2 grafts per patient; range, 1 to 3). Forty-eight grafts were studied in the 43 patients undergoing completion arteriography. There were 4 findings on arteriogram leading to further immediate intervention (8.3%). These included 3 grafts with anastomotic stenoses or spasm requiring stent placement, and 1 patient who had limited dissection in the left internal mammary artery graft and underwent placement of an additional vein graft. These findings were independent of electrocardiographic changes or hemodynamic instability. The remainder of the studies showed no significant abnormalities. There were no deaths. One patient who did not have a completion arteriogram suffered a postoperative myocardial infarction requiring stent placement for anastomotic stenosis. Patients were discharged home an average of 6.8 days postoperatively. There were no instances of renal dysfunction postoperatively attributable to catheterization. Minimally invasive coronary artery bypass is safe and effective. Findings of completion arteriography occasionally reveal previously under-recognized findings that, if corrected in a timely fashion, could potentially impact graft patency and clinical outcomes. Our experience validates this minimally invasive technique. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Changes in myocardial perfusion due to physical exercise in patients with stable coronary artery disease

    International Nuclear Information System (INIS)

    Kendziorra, Kai; Foerster, Marcus; Sabri, Osama; Kluge, Regine; Walther, Claudia; Moebius-Winkler, Sven; Conradi, Katrin; Schuler, Gerhard; Hambrecht, Rainer

    2005-01-01

    Percutaneous transluminal coronary angioplasty (PTCA) is one of the main therapy options for patients with coronary artery disease (CAD), resulting in an improvement in myocardial perfusion and exercise capacity. Nevertheless, studies have also demonstrated a positive effect of regular exercise training on myocardial perfusion and maximum exercise capacity. The aim of this study was to evaluate changes in myocardial stress perfusion after 1 year of exercise training in comparison with the effects of PTCA in patients with CAD. In 66 male patients with angiographically confirmed significant coronary artery stenosis in one target vessel, myocardial perfusion scintigraphy was performed at baseline and 12 months after randomisation into either a physical exercise group or a PTCA group. Circumferential count rate profiles in 16 wall segments were classified according to their relative count rate and localisation within or outside the area supplied by the stenosed vessel. Ischaemic segments showed a significant improvement in myocardial count rate within the target area after 12 months in both the PTCA and the training group (PTCA group: from 76.8±4.9% to 86.6±10.9%, p=0.03; training group: from 74.0±7.3% to 83.7±10.8%, p<0.01). Outside the target area only the training group showed a significant improvement (from 77.7±4.4% to 91.7±4.8%, p<0.01). Our data indicate a significant improvement in stress myocardial perfusion in the training group after 12 months. The ischaemia is reduced not only in the target region of the leading stenosis but also in other ischaemic myocardial areas. In contrast, after PTCA stress perfusion improves only in the initially ischaemic parts of the target area. (orig.)

  14. Clinical Relevance of 18F-Sodium Fluoride Positron-Emission Tomography in Noninvasive Identification of High-Risk Plaque in Patients With Coronary Artery Disease.

    Science.gov (United States)

    Lee, Joo Myung; Bang, Ji-In; Koo, Bon-Kwon; Hwang, Doyeon; Park, Jonghanne; Zhang, Jinlong; Yaliang, Tong; Suh, Minseok; Paeng, Jin Chul; Shiono, Yasutsugu; Kubo, Takashi; Akasaka, Takashi

    2017-11-01

    18 F-sodium fluoride ( 18 F-NaF) positron-emission tomography has been introduced as a potential noninvasive imaging tool to identify plaques with high-risk characteristics in patients with coronary artery disease. We sought to evaluate the clinical relevance of 18 F-NaF uptake using optical coherence tomography (OCT), intravascular ultrasound (IVUS), and coronary computed tomography angiography in patients with coronary artery disease. The target population consisted of 51 prospectively enrolled patients (93 stenoses) who underwent 18 F-NaF positron-emission tomography before invasive coronary angiography. 18 F-NaF uptake was compared with IVUS- and OCT-derived plaque characteristics. In the coronary computed tomography angiography subgroup (46 lesions), qualitative lesion characteristics were compared between 18 F-NaF-positive and 18 F-NaF-negative plaques using adverse plaque characteristics. The plaques with 18 F-NaF uptake showed significantly higher plaque burden, more frequent posterior attenuation and positive remodeling in IVUS, and significantly higher maximum lipid arc and more frequent microvessels in OCT (all P characteristics. The 18 F-NaF tissue-to-background ratio in plaques with high-risk characteristics was significantly higher than in those without (1.09 [95% confidence interval, 0.85-1.34] versus 0.62 [95% confidence interval, 0.42-0.82], P characteristics between 18 F-NaF-positive and 18 F-NaF-negative plaques in the coronary computed tomography angiography subgroup (85.2% versus 78.9%; P =0.583). This study's results suggest that 18 F-NaF positron-emission tomography can be a useful noninvasive diagnostic tool to identify and localize plaque with high-risk characteristics. URL: http://www.clinicaltrials.gov. Unique identifier: NCT02388412. © 2017 American Heart Association, Inc.

  15. [Developments in percutaneous coronary intervention and coronary stents].

    Science.gov (United States)

    Simsek, C; Daemen, J; Zijlstra, F

    2014-01-01

    In The Netherlands, more than 30.000 patients undergo a percutaneous coronary intervention every year, during which a coronary stent implantation will be performed in 90% of the cases. It is estimated that more than 5 million coronary stent implantations will be performed worldwide this year. While these numbers are impressive, however, coronary stents still have as a limitation the possibility of stent thrombosis. This has been and is an important stimulus for the development of both coronary stents, from a bare metal stent via a drug eluting stent to the present-day development of bio-absorbable stents, and anti-platelet drugs,from acenocoumarol to thieropyridines. The possibility of shortening the period of use of this powerful medication by developing new kinds of non-thrombogenic stents would, for example, make it possible to achieve significant reductions in subsequent bleeding during (dental) procedures.

  16. Acclimatization of in Vitro-derived Dendrobium

    Directory of Open Access Journals (Sweden)

    Jaime A. Teixeira da Silva

    2017-05-01

    Full Text Available The successful ex vitro establishment of Dendrobium plantlets raised in vitro determines the quality of the end product (cut flowers or potted plants in commercial production for economic gain. When in vitro Dendrobium plantlets are transplanted from the culture room to greenhouse conditions, they may desiccate or wilt rapidly and can die as a result of changes in the environment, unless substantial precautions are taken to adapt plantlets to a new environment. The acclimatization of in vitro-grown Dendrobium plantlets to an ex vitro environment by gradually weaning them towards ambient relative humidity and light levels facilitates better survival of young and physiologically sensitive plantlets. Dendrobium plantlets raised in vitro must thus undergo a period of acclimatization or transitional development to correct anatomical abnormalities and to enhance their physiological performance to ensure survival under ex vitro conditions. The most common approach to improve the survival of Dendrobium plantlets upon transfer to an ex vitro environment is their gradual adaptation to that environment. Under such conditions, plants convert rapidly from a heterotrophic or photomixotrophic state to an autotrophic growth, develop a fully functional root system, and better control their stomatal and cuticular transpiration. Gradual adaptation is carried out in a greenhouse by decreasing relative humidity using fog or mist chambers and by increasing light intensity using shading techniques. This review details the acclimatization and ex vitro survival of Dendrobium plants produced in vitro. This advice is also useful for other orchids.

  17. In vitro remineralization of in vivo and in vitro formed enamel lesions

    NARCIS (Netherlands)

    Iijima, Y; Takagi, O; Ruben, J; Arends, J

    1999-01-01

    Thin sections of natural white spot enamel lesions (WS) and of artificial in vitro lesions (VL) were remineralized simultaneously in vitro. The sections, clamped in a PMMA holder, were microradiographed at baseline and after remineralization in a calcium- and phosphate-containing solution (pH = 7.0;

  18. In vitro techniques for crop improvement

    International Nuclear Information System (INIS)

    1985-01-01

    The film refers to principles of plant tissue culture - laboratory requirements, media preparation, explant establishment and subculturing method. In vitro growth and development of crop plants are demonstrate and the application of in vitro techniques in plant breeding is discussed. The second part of the film shows the application of cell, tissue and organ culture in plants. Micropropagation and virus eradication are important technologies for the improvement of vegetatively propagated plants; zygotic embryo rescue techniques are used for distant hybridization, especially in cereals. Plant biotechnology offers a potent means for the in vitro generation of enhanced genetic variability - somaclonal and mutagen induced variation. Principles of the isolation and culture of plant protoplasts are explained and their potential for somatic hybridization in higher plants is demonstrated. Haploids are valuable to accelerate breeding cycles of plants. Plant biotechnology is described as an important complementary tool to conventional plant breeding methods

  19. In vitro manipulation techniques of porcine embryos

    DEFF Research Database (Denmark)

    Liu, Ying; Li, Juan; Løvendahl, Peter

    2015-01-01

    During the last 17 years, considerable advancements have been achieved in the production of pigs, transgenic and non-transgenic, by methods of somatic cell nuclear transfer, in vitro fertilisation, intracytoplasmic sperm injection, microinjection and sperm-mediated gene transfer by artificial...... insemination. Therefore, a review of the overall efficiency for the developmental competence of embryos produced by these in vitro methods would be useful in order to obtain a more thorough overview of this growing area with respect to its development and present status. In this review a meta-analysis was used...... to analyse data collected from all published articles with a focus on zygotes and embryos for transfer, pregnancy, full-term development and piglets born. It was generally concluded that an increasing level of in vitro manipulation of porcine embryos decreased the overall efficiency for production of piglets...

  20. In vitro propagation of Paphiopedilum orchids.

    Science.gov (United States)

    Zeng, Songjun; Huang, Weichang; Wu, Kunlin; Zhang, Jianxia; da Silva, Jaime A Teixeira; Duan, Jun

    2016-01-01

    Paphiopedilum is one of the most popular and rare orchid genera. Members of the genus are sold and exhibited as pot plants and cut flowers. Wild populations of Paphiopedilum are under the threat of extinction due to over-collection and loss of suitable habitats. A reduction in their commercial value through large-scale propagation in vitro is an option to reduce pressure from illegal collection, to attempt to meet commercial needs and to re-establish threatened species back into the wild. Although they are commercially propagated via asymbiotic seed germination, Paphiopedilum are considered to be difficult to propagate in vitro, especially by plant regeneration from tissue culture. This review aims to cover the most important aspects and to provide an up-to-date research progress on in vitro propagation of Paphiopedilum and to emphasize the importance of further improving tissue culture protocols for ex vitro-derived explants.

  1. In vitro folding of inclusion body proteins.

    Science.gov (United States)

    Rudolph, R; Lilie, H

    1996-01-01

    Insoluble, inactive inclusion bodies are frequently formed upon recombinant protein production in transformed microorganisms. These inclusion bodies, which contain the recombinant protein in an highly enriched form, can be isolated by solid/liquid separation. After solubilization, native proteins can be generated from the inactive material by using in vitro folding techniques. New folding procedures have been developed for efficient in vitro reconstitution of complex hydrophobic, multidomain, oligomeric, or highly disulfide-bonded proteins. These protocols take into account process parameters such as protein concentration, catalysis of disulfide bond formation, temperature, pH, and ionic strength, as well as specific solvent ingredients that reduce unproductive side reactions. Modification of the protein sequence has been exploited to improve in vitro folding.

  2. In vitro technology for mutation breeding

    International Nuclear Information System (INIS)

    1986-10-01

    The ultimate aim of the Co-ordinated Research Programme on In Vitro Technology for Mutation Breeding is to provide new effective tools for plant breeders to construct new cultivars, thus increasing agricultural production of food, feed and industrial raw material, particularly in developing countries. The participants of the research co-ordination meetings considered the potential of new advances of agricultural biotechnology, especially the use of in vitro techniques for mutation breeding. They discussed and co-ordinated plans in conjunction with the impact on plant breeding of novel technologies, such as use of somaclonal variation, cell hybridization and molecular genetics

  3. Do prostaglandins affect cellular radiosensitivity in vitro

    International Nuclear Information System (INIS)

    Millar, B.C.; Jinks, S.

    1984-01-01

    The authors were unable to detect any change in the in vitro radiation response of mouse fibrosarcoma cells, HSDM 1 C 1 , which secrete 2 μg PGE 2 /mg cell protein/24 h, in the presence of the prostaglandin biosynthesis inhibitor flurbiprofen. Furthermore, addition of exogenous PGE 1 or PGA 2 to cultures of Chinese hamster cells was similarly without effect on radiation response. Although a high concentration of PGA 2 inhibited the growth of Chinese hamster cells in vitro this effect disappeared upon removal of the prostaglandin. The implications of these results for radiotherapy are discussed. (author)

  4. Do prostaglandins affect cellular radiosensitivity in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Millar, B.C.; Jinks, S. (Institute of Cancer Research, Sutton (UK). Surrey Branch)

    1984-10-01

    The authors were unable to detect any change in the in vitro radiation response of mouse fibrosarcoma cells, HSDM/sub 1/C/sub 1/, which secrete 2 ..mu..g PGE/sub 2//mg cell protein/24 h, in the presence of the prostaglandin biosynthesis inhibitor flurbiprofen. Furthermore, addition of exogenous PGE/sub 1/ or PGA/sub 2/ to cultures of Chinese hamster cells was similarly without effect on radiation response. Although a high concentration of PGA/sub 2/ inhibited the growth of Chinese hamster cells in vitro this effect disappeared upon removal of the prostaglandin. The implications of these results for radiotherapy are discussed.

  5. In vitro test for pyrogenes in radiopharmaceuticals

    Energy Technology Data Exchange (ETDEWEB)

    Jovanovic, V; Zmbova, B; Bzenic, J [Institut za Nuklearne Nauke Boris Kidric, Belgrade (Yugoslavia); Berkes, J [Institut za Biohemije, Belgrade (Yugoslavia)

    1978-05-01

    Procedure and results of determination of pyrogenic substances in radiopharmaceutical preparations by an in vitro method based on the reaction between bacterial endotoxine and Limulus Amebocyte Lysate are presented. The advantage of this method as compared to the test in experimental animals performed so far has also been analyzed and proved by the fact that it enables avoidance of introduction of radioactive materials in experimental animals and of radiation effects on the results obtained in efficiency studies. The in vitro method is a quick one and requires only small quantities of the radiopharmaceutical preparation to be examined.

  6. [In vitro metabolism of fenbendazole prodrug].

    Science.gov (United States)

    Wen, Ai-Dan; Duan, Li-Ping; Liu, Cong-Shan; Tao, Yi; Xue, Jian; Wu, Ning-Bo; Jiang, Bin; Zhang, Hao-Bing

    2013-02-01

    Synthesized fenbendazole prodrug N-methoxycarbonyl-N'-(2-nitro-4-phenylthiophenyl) thiourea (MPT) was analyzed in vitro in artificial gastric juice, intestinal juice and mouse liver homogenate model by using HPLC method, and metabolic curve was then generated. MPT was tested against Echinococcus granulosus protoscolices in vitro. The result showed that MPT could be metabolized in the three biological media, and to the active compound fenbendazole in liver homogenate, with a metabolic rate of 7.92%. Besides, the prodrug showed a weak activity against E. granulosus protoscolices with a mortality of 45.9%.

  7. Balloon dilatation and balloon-expandable stents for PTA of proximal venous stenoses in haemodialysis patients. Dilatation und ballonexpandierbare Stents zur Therapie zentralvenoeser Stenosen bei Dialysepatienten

    Energy Technology Data Exchange (ETDEWEB)

    Landwehr, P; Lackner, K [Wuerzburg Univ. (Germany, F.R.). Inst. fuer Roentgendiagnostik; Goetz, R [Wuerzburg Univ. (Germany, F.R.). Abt. fuer Nephrologie

    1990-09-01

    On 10 dialysis patients we performed 12 balloon dilatations, 2 catheter lyses, 6 stent implants (Palmaz stent) and one atherectomy of central venous stenoses or occlusions (v. subclavia, v. brachiocephalica) at the shunt arm of the patient. The primary success rate was, in balloon PTA and lysis, 12/14 interventions, and in stent placement and atherectomy 7/7. The angiographical and clinical primary result after stent implantation was significantly better than after conventional dilatation. After 66% of the balloon dilatations recidivation occurred within the first year; this can be treated by means of repeated PTA. Whether long-term exclusion of recurrence can be achieved by stent implantation, must be established by means of follow-up studies that are at present in progress. (orig.).

  8. Changes in the vessels following aorto-coronary bypass operation

    International Nuclear Information System (INIS)

    Goebel, N.; Pfluger, N.; Speiser, K.; Turina, M.; Rothlin, M.; Zurich Univ.; Zurich Univ.

    1983-01-01

    In a prospective study (238 men, mean age 53 years) the changes of the native vessels were studied 3 months after a-c-bypass operation and 5 months after preop. angiography. Progression was defined as increase of stenoses of at least 20% or new total occlusion. Progression was significantly more frequent in vessels with than without bypass and was located proximally to the anastomoses in most cases, less frequently at the anastomoses and very rarely distally to the anastomoses. Proximal progression was significantly more frequent with patent than with occluded bypasses. Stenoses at the anastomoses were significantly more frequent with occluded than with patent bypasses. Stenoses of higher degrees hat a stonger tendency for progression than slighter stenoses. Regression was rare and nearly always caused by surgery. (orig.) [de

  9. Comprehensive Assessment of Coronary Artery Disease by Using First-Pass Analysis Dynamic CT Perfusion: Validation in a Swine Model.

    Science.gov (United States)

    Hubbard, Logan; Lipinski, Jerry; Ziemer, Benjamin; Malkasian, Shant; Sadeghi, Bahman; Javan, Hanna; Groves, Elliott M; Dertli, Brian; Molloi, Sabee

    2018-01-01

    Purpose To retrospectively validate a first-pass analysis (FPA) technique that combines computed tomographic (CT) angiography and dynamic CT perfusion measurement into one low-dose examination. Materials and Methods The study was approved by the animal care committee. The FPA technique was retrospectively validated in six swine (mean weight, 37.3 kg ± 7.5 [standard deviation]) between April 2015 and October 2016. Four to five intermediate-severity stenoses were generated in the left anterior descending artery (LAD), and 20 contrast material-enhanced volume scans were acquired per stenosis. All volume scans were used for maximum slope model (MSM) perfusion measurement, but only two volume scans were used for FPA perfusion measurement. Perfusion measurements in the LAD, left circumflex artery (LCx), right coronary artery, and all three coronary arteries combined were compared with microsphere perfusion measurements by using regression, root-mean-square error, root-mean-square deviation, Lin concordance correlation, and diagnostic outcomes analysis. The CT dose index and size-specific dose estimate per two-volume FPA perfusion measurement were also determined. Results FPA and MSM perfusion measurements (P FPA and P MSM ) in all three coronary arteries combined were related to reference standard microsphere perfusion measurements (P MICRO ), as follows: P FPA_COMBINED = 1.02 P MICRO_COMBINED + 0.11 (r = 0.96) and P MSM_COMBINED = 0.28 P MICRO_COMBINED + 0.23 (r = 0.89). The CT dose index and size-specific dose estimate per two-volume FPA perfusion measurement were 10.8 and 17.8 mGy, respectively. Conclusion The FPA technique was retrospectively validated in a swine model and has the potential to be used for accurate, low-dose vessel-specific morphologic and physiologic assessment of coronary artery disease. © RSNA, 2017.

  10. The use of indium-111 platelet scintigraphy in man: comparisons with in vitro tests and in vivo platelet function--a five year experience

    International Nuclear Information System (INIS)

    Ezikowitz, M.D.; Ferri, P.; Pope, C.; Smith, E.O.; Snyder, E.L.

    1985-01-01

    In this paper, the authors present data collected from 540 patients between July 1978 and July 1983. They discuss briefly the method they employed for labeling platelets, emphasizing in vivo and in vitro markers of platelet function used for quality control of platelet preparation. They discuss the application of their technique for identification of mural left ventrical trombi, and review the disparity between in vivo and in vitro tests of platelet function. Then they deal with diagnosis of subacute bacterial endocarditis, deep veonus thrombosis, coronary trombi, left arterial masses, and the use of tomographic imaging. Finally they report changes in platelet function in stored platelets from normal volunteers

  11. A rare anomaly: Double right coronary artery

    Directory of Open Access Journals (Sweden)

    Dursun Çayan Akkoyun

    2013-01-01

    Full Text Available Coronary artery anomalies are rare anomalies. Theseare usually asymptomatic and are discovered incidentally.Double right coronary artery (RCA is a rare coronaryartery anomaly. Although there is controversy aboutidentification and classification of double RCA, it is oftena benign condition, but it can be complicated by atherosclerosisand can lead to serious conditions such asmyocardial infarction (MI and may be accompanied byother anomalies. In our case, double RCA were detectedin coronary angiography for acute anterior MI, and in thenext session successful percutaneous coronary interventionwas performed.Key words: Coronary anomaly, coronary angiography,coronary stenosis

  12. Current status of hybrid coronary revascularization.

    Science.gov (United States)

    Jaik, Nikhil P; Umakanthan, Ramanan; Leacche, Marzia; Solenkova, Natalia; Balaguer, Jorge M; Hoff, Steven J; Ball, Stephen K; Zhao, David X; Byrne, John G

    2011-10-01

    Hybrid coronary revascularization combines coronary artery bypass surgery with percutaneous coronary intervention techniques to treat coronary artery disease. The potential benefits of such a technique are to offer the patients the best available treatments for coronary artery disease while minimizing the risks of the surgery. Hybrid coronary revascularization has resulted in the establishment of new 'hybrid operating suites', which incorporate and integrate the capabilities of a cardiac surgery operating room with that of an interventional cardiology laboratory. Hybrid coronary revascularization has greatly augmented teamwork and cooperation between both fields and has demonstrated encouraging as well as good initial outcomes.

  13. A survey of contrast media used in coronary angiograph

    International Nuclear Information System (INIS)

    Weikl, A.; Hubmann, M.

    1982-01-01

    In recent years, various contrast media have been developed for use in coronary angiography. These contrast media may be divided into ionic contrast media of high osmolality, those of low osmolality, and nonionic contrast materials. We conducted our own clinical studies with 40 patients. In random succession a standard contrast medium (ionic, of high osmolality) and a new-generation contrast medium (either nonionic or ionic with low osmolality) were injected into the right and left coronary arteries. After each injection we measured the systolic and diastolic blood pressure using a liquid-filled coronary catheter. In addition, the change in the length of the cardiac cycle was registered in terms of the R-R interval (in ms) and at the same time, leads I, II, and III of the ECG were recorded. We studied the influence of the various contrast media on the activity of ATPase in in vitro experiments, using Lasser and Lang's. When ionic contrast media of low osmolality and nonionic contrast media were utilized the heart rate showed no change. Disturbances of rhythm such as ventricular tachycardia or fibrillation were not observed. All of the contrast media used produced the same ECG changes. These changes can be ascribed to the inhibition of ATPase. The arterial blood pressure was lowered significantly only by ionic contrast media of high osmolality only. (orig.)

  14. Microengineered in vitro model of cardiac fibrosis through modulating myofibroblast mechanotransduction

    International Nuclear Information System (INIS)

    Zhao, Hui; Li, Xiaokang; Zhao, Shan; Zeng, Yang; Ding, Haiyan; Du, Yanan; Zhao, Long; Sun, Wei

    2014-01-01

    Cardiac fibrosis greatly impairs normal heart function post infarction and there is no effective anti-fibrotic drug developed at present. The current therapies for cardiac infarction mainly take effect by eliminating occlusion in coronary artery by thrombolysis drugs, vascular stent grafting or heart bypass operation, which are capable to provide sufficient blood flow for intact myocardium yet showed subtle efficacy in ameliorating fibrosis condition. The advances of in vitro cell/tissue models open new avenues for drug assessment due to the low cost, good controllability and availability as well as the convenience for operation as compared to the animal models. To our knowledge, no proper biomimetic in vitro cardiac fibrosis model has been reported yet. Here we engineered an in vitro cardiac fibrosis model using heart-derived fibroblasts, and the fibrogenesis was recapitulated by patterning the substrate rigidity which mimicked the mechanical heterogeneity of myocardium post-infarction. Various biomarkers for cardiac fibrosis were assayed to validate the biomimicry of the engineered platform. Subsequent addition of Rho-associated protein kinase (ROCK) pathway inhibitor reduced the ratio of myofibroblasts, indicating the feasibility of applying this platform in screening anti-fibrosis drugs. (paper)

  15. APpropriAteness of percutaneous Coronary interventions in patients with ischaemic HEart disease in Italy: the APACHE pilot study

    Science.gov (United States)

    Marino, Marcello; Crimi, Gabriele; Maiorana, Florinda; Rizzotti, Diego; Lettieri, Corrado; Bettari, Luca; Zuccari, Marco; Sganzerla, Paolo; Tresoldi, Simone; Adamo, Marianna; Ghiringhelli, Sergio; Sponzilli, Carlo; Pasquetto, Giampaolo; Pavei, Andrea; Pedon, Luigi; Bassan, Luciano; Bollati, Mario; Camisasca, Paola; Trabattoni, Daniela; Brancati, Marta; Poli, Arnaldo; Panciroli, Claudio; Lettino, Maddalena; Tarelli, Giuseppe; Tarantini, Giuseppe; De Luca, Leonardo; Varbella, Ferdinando; Musumeci, Giuseppe; De Servi, Stefano

    2017-01-01

    Objectives To first explore in Italy appropriateness of indication, adherence to guideline recommendations and mode of selection for coronary revascularisation. Design Retrospective, pilot study. Setting 22 percutaneous coronary intervention (PCI)-performing hospitals (20 patients per site), 13 (59%) with on-site cardiac surgery. Participants 440 patients who received PCI for stable coronary artery disease (CAD) or non-ST elevation acute coronary syndrome were independently selected in a 4:1 ratio with half diabetics. Primary and secondary outcome measures Proportion of patients who received appropriate PCI using validated appropriate use scores (ie, AUS≥7). Also, in patients with stable CAD, we examined adherence to the following European Society of Cardiology recommendations: (A) per cent of patients with complex coronary anatomy treated after heart team discussion; (B) per cent of fractional flow reserve-guided PCI for borderline stenoses in patients without documented ischaemia; (C) per cent of patients receiving guideline-directed medical therapy at the time of PCI as well as use of provocative test of ischaemia according to pretest probability (PTP) of CAD. Results Of the 401 mappable PCIs (91%), 38.7% (95% CI 33.9 to 43.6) were classified as appropriate, 47.6% (95% CI 42.7 to 52.6) as uncertain and 13.7% (95% CI 10.5% to 17.5%) as inappropriate. Median PTP in patients with stable CAD without known coronary anatomy was 69% (78% intermediate PTP, 22% high PTP). Ischaemia testing use was similar (p=0.71) in patients with intermediate (n=140, 63%) and with high PTP (n=40, 66%). In patients with stable CAD (n=352) guideline adherence to the three recommendations explored was: (A) 11%; (B) 25%; (C) 23%. AUS was higher in patients evaluated by the heart team as compared with patients who were not (7 (6.8) vs 5 (4.7); p=0.001). Conclusions Use of heart team approaches and adherence to guideline recommendations on coronary revascularisation in a real-world setting

  16. Non-invasive assessment of coronary calcification

    International Nuclear Information System (INIS)

    Vliegenthart, Rozemarijn; Oei, Hok-Hay S.; Hofman, Albert; Oudkerk, Matthijs; Witteman, Jackqueline C. M.

    2004-01-01

    Electron-beam tomography (EBT) and multi-detector computed tomography (MDCT) enable the noninvasive assessment of coronary calcification. The amount of coronary calcification, as detected by EBT, has a close relation with the amount of coronary atherosclerosis, which is the substrate for the occurrence of myocardial infarction and sudden cardiac death. Calcification of the coronary arteries can be seen as a cumulative measure of life-time exposure to cardiovascular risk factors. Several studies have shown that the amount of coronary calcification is associated with the risk of coronary heart disease. Therefore, coronary calcification is a promising method for non-invasive detection of asymptomatic subjects at high risk of developing coronary heart disease. Whether measurement of coronary calcification also increases the predictive power of coronary events based on cardiovascular risk factors is topic of current research

  17. Differential effects of androgens on coronary blood flow regulation and arteriolar diameter in intact and castrated swine

    Directory of Open Access Journals (Sweden)

    O’Connor Erin K

    2012-05-01

    Full Text Available Abstract Background Low endogenous testosterone levels have been shown to be a risk factor for the development of cardiovascular disease and cardiovascular benefits associated with testosterone replacement therapy are being advocated; however, the effects of endogenous testosterone levels on acute coronary vasomotor responses to androgen administration are not clear. The objective of this study was to compare the effects of acute androgen administration on in vivo coronary conductance and in vitro coronary microvascular diameter in intact and castrated male swine. Methods Pigs received intracoronary infusions of physiologic levels (1–100 nM of testosterone, the metabolite 5α-dihydrotestosterone, and the epimer epitestosterone while left anterior descending coronary blood flow and mean arterial pressure were continuously monitored. Following sacrifice, coronary arterioles were isolated, cannulated, and exposed to physiologic concentrations (1–100 nM of testosterone, 5α-dihydrotestosterone, and epitestosterone. To evaluate effects of the androgen receptor on acute androgen dilation responses, real-time PCR and immunohistochemistry for androgen receptor were performed on conduit and resistance coronary vessels. Results In vivo, testosterone and 5α-dihydrotestosterone produced greater increases in coronary conductance in the intact compared to the castrated males. In vitro, percent maximal dilation of microvessels was similar between intact and castrated males for testosterone and 5α-dihydrotestosterone. In both studies epitestosterone produced significant increases in conductance and microvessel diameter from baseline in the intact males. Androgen receptor mRNA expression and immunohistochemical staining were similar in intact and castrated males. Conclusions Acute coronary vascular responses to exogenous androgen administration are increased by endogenous testosterone, an effect unrelated to changes in androgen receptor expression.

  18. Babesia bigemina: in vitro cultivation and characterization

    International Nuclear Information System (INIS)

    Vega Y Murguia, C.A.

    1985-01-01

    An in vitro model for the continuous replication of Babesia bigemina was developed and this model was used to study the parasite's biology. Initially, infected erythrocytes from a calf inoculated with a strain of B. bigemina was suspended with normal bovine erythrocytes and the parasite propagated in vitro. The cultured organism was inoculated into another calf and reproduced the disease with typical signs. Babesia bigemina was reisolated in pure culture in vitro. The animal recovered after receiving specific treatment. A procedure was developed to cryopreserve infected erythrocytes and merozoites to initiate in vitro cultures. Homogeneous parasite populations were obtained by cloning by limiting dilution. Parasitic growth was detected between 16-28 days after dilutions were made. Three primary clones were selected for recloning. Infected erythrocytes from the original isolate nd the clones were concentrated by Percoll density gradients. Density values for paired and single infected cells were determined. Enzymatic content of concentrated infected cells was analyzed by starch gel electrophoresis. Enzymes LDH, GPI, and GDH were detected, but polymorphism among clones was not observed. The enzyme 6-PDG was not associated with the parasite. Separation of labelled proteins was done by SDS-PAGE. The separation patterns were similar for all samples. a 43 Kd polypeptide was detected in the B. bigemina culture supernatant

  19. Immunobiological Effects of Glucosamine In Vitro

    DEFF Research Database (Denmark)

    Forchhammer, L; Thorn, M; Met, O

    2003-01-01

    Glucosamine (GlcN) and N-acetyl-d-glucosamine (GlcNAc) were assayed in vitro for their effects on proliferation, cytotoxicity and cytokine secretion in primary and secondary mixed lymphocyte cultures (MLCs). In addition, we studied the effect of GlcN and GlcNAc on the proliferation of purified CD4...

  20. In vitro systems in pneumocystis research

    DEFF Research Database (Denmark)

    Dei-Cas, E; Cailliez, J C; Lundgren, Bettina

    1996-01-01

    as well as elimination of host cell debris from parasite extracts. In other investigations, such as transmission, infectivity, life cycle, biochemical, in vitro culture or drug-screening studies, viable and infectious Pneumocystis organisms are urgently required. However, there is no generally accepted...

  1. Cortisol suppresses radiation transformation in vitro

    International Nuclear Information System (INIS)

    Kennedy, A.R.

    1985-01-01

    It is reported that 10 -7 M cortisol has a significant suppressive effect on radiation-induced transformation in vitro in C3H10T 1/2 cells. Previously reported data showed a significant enhancing effect for similar experiments performed with cortisone. Thus, these two structurally similar glucocorticoid hormones have opposite effects on transformation induced by ionizing radiation. (author)

  2. In vitro microrhizome production in Decalepis hamiltonii

    African Journals Online (AJOL)

    SAM

    2014-03-12

    Mar 12, 2014 ... Micro-rhizomes have been induced in Curcuma aromatica, Curcuma longa and the efficiency of microrhizome formation was found to be determined by the concentration of cytokinins, sucrose and coconut milk. (Naik and Naik, 2006). Production of microrhizomes in vitro has many advantages compared to ...

  3. Fluconazole inhibits human adrenocortical steroidogenesis in vitro

    NARCIS (Netherlands)

    R. van der Pas (Rob); L.J. Hofland (Leo); J. Hofland (Johannes); A.E. Taylor (A.); W. Arlt (Wiebke); J. Steenbergen (Jacobie); P.M. van Koetsveld (Peter); W.W. de Herder (Wouter); F.H. de Jong (Frank); R.A. Feelders (Richard)

    2012-01-01

    textabstractThe antifungal agent ketoconazole is often used to suppress cortisol production in patients with Cushing's syndrome (CS). However, ketoconazole has serious side effects and is hepatotoxic. Here, the in vitro effects of ketoconazole and fluconazole, which might be less toxic, on human

  4. Stress in plants cultured in vitro

    NARCIS (Netherlands)

    Klerk, de G.J.M.

    2007-01-01

    Plants subjected to stress display various defense mechanisms. On base of these mechanisms, stress-protective measures can be developed. This paper deals with protection brought about by putrescine. An in vitro system to impose drought stress was developed and the protective effect of putrescine on

  5. In Vitro Dosimetry of Silver Nanoparticles

    Science.gov (United States)

    An important issue for interpreting in vitro nanomaterial testing is quantifying the dose absorbed by target cells. Considerations include the concentration added to the culture and the proportion of the applied dose that is absorbed by the target cells. Rapid and efficient techn...

  6. Mammalian oocyte growth and development in vitro.

    Science.gov (United States)

    Eppig, J J; O'Brien, M; Wigglesworth, K

    1996-06-01

    This paper is a review of the current status of technology for mammalian oocyte growth and development in vitro. It compares and contrasts the characteristics of the various culture systems that have been devised for the culture of either isolated preantral follicles or the oocyte-granulosa cell complexes form preantral follicles. The advantages and disadvantages of these various systems are discussed. Endpoints for the evaluation of oocyte development in vitro, including oocyte maturation and embryogenesis, are described. Considerations for the improvement of the culture systems are also presented. These include discussions of the possible effects of apoptosis and inappropriate differentiation of oocyte-associated granulosa cells on oocyte development. Finally, the potential applications of the technology for oocyte growth and development in vitro are discussed. For example, studies of oocyte development in vitro could help to identify specific molecules produced during oocyte development that are essential for normal early embryogenesis and perhaps recognize defects leading to infertility or abnormalities in embryonic development. Moreover, the culture systems may provide the methods necessary to enlarge the populations of valuable agricultural, pharmaceutical product-producing, and endangered animals, and to rescue the oocytes of women about to undergo clinical procedures that place oocytes at risk.

  7. Integration of QSAR and in vitro toxicology.

    Science.gov (United States)

    Barratt, M D

    1998-01-01

    The principles of quantitative structure-activity relationships (QSAR) are based on the premise that the properties of a chemical are implicit in its molecular structure. Therefore, if a mechanistic hypothesis can be proposed linking a group of related chemicals with a particular toxic end point, the hypothesis can be used to define relevant parameters to establish a QSAR. Ways in which QSAR and in vitro toxicology can complement each other in development of alternatives to live animal experiments are described and illustrated by examples from acute toxicological end points. Integration of QSAR and in vitro methods is examined in the context of assessing mechanistic competence and improving the design of in vitro assays and the development of prediction models. The nature of biological variability is explored together with its implications for the selection of sets of chemicals for test development, optimization, and validation. Methods are described to support the use of data from in vivo tests that do not meet today's stringent requirements of acceptability. Integration of QSAR and in vitro methods into strategic approaches for the replacement, reduction, and refinement of the use of animals is described with examples. PMID:9599692

  8. Validation of in vitro probabilistic tractography

    DEFF Research Database (Denmark)

    Dyrby, Tim B.; Sogaard, L.V.; Parker, G.J.

    2007-01-01

    assessed the anatomical validity and reproducibility of in vitro multi-fiber probabilistic tractography against two invasive tracers: the histochemically detectable biotinylated dextran amine and manganese enhanced magnetic resonance imaging. Post mortern DWI was used to ensure that most of the sources...

  9. Study in vitro of origin radioprotective food the radioprotective effect in vitro of food borne; Estudio in vitro de radioprotectores de origen alimentario

    Energy Technology Data Exchange (ETDEWEB)

    Soraino, J. M.; Sebastia, N.; Almonacid, M.; Alonso, O.; Cervera, J.; Such, E.; Silla, M. A.; Villaescusa, J. I.; Montoro, A.

    2012-07-01

    Study in vitro of origin radioprotective food the radioprotective effect in vitro of food borne substances studied is a first step in developing effective radioprotectors that can prevent radiation damage to healthy tissue., cannot forget that these studies must be accompanied by in vitro studies of toxicity and bioavailability to profile designing radioprotective substance.

  10. Diagnosing coronary artery disease after a positive coronary computed tomography angiography

    DEFF Research Database (Denmark)

    Nissen, L; Winther, S; Westra, J

    2018-01-01

    Aims: Perfusion scans after coronary computed tomography angiography (CCTA) in patients with suspected coronary artery disease (CAD) may reduce unnecessary invasive coronary angiographies (ICAs). However, the diagnostic accuracy of perfusion scans after primary CCTA is unknown. The aim...

  11. Vessel dilatation in coronary angiograms

    International Nuclear Information System (INIS)

    Hinterauer, L.; Goebel, N.

    1983-01-01

    Amongst 166 patients with aneurysms, ectasia or megaloarteries shown on coronary angiograms, 86.1% had dilated vessels as part of generalised coronary sclerosis (usually in patients with three-vessel disease). In 9%, dilatation was of iatrogenic origin and in 4.8% it was idiopathic. One patient had Marfan's syndrome. Amongst 9 000 patients, there were eight with megalo-arteries without stenosis; six of these had atypical angina and three suffered an infarct. Patients with definite dilatation of the coronary artery and stagnation of contrast flow required treatment. (orig.) [de

  12. Vessel dilatation in coronary angiograms

    Energy Technology Data Exchange (ETDEWEB)

    Hinterauer, L.; Goebel, N.

    1983-11-01

    Amongst 166 patients with aneurysms, ectasia or megaloarteries shown on coronary angiograms, 86.1% had dilated vessels as part of generalised coronary sclerosis (usually in patients with three-vessel disease). In 9%, dilatation was of iatrogenic origin and in 4.8% it was idiopathic. One patient had Marfan's syndrome. Amongst 9 000 patients, there were eight with megalo-arteries without stenosis; six of these had atypical angina and three suffered an infarct. Patients with definite dilatation of the coronary artery and stagnation of contrast flow required treatment.

  13. Management of coronary artery disease

    Science.gov (United States)

    Safri, Z.

    2018-03-01

    Coronary Artery Disease (CAD) is associated with significant morbidity and mortality, therefore it’s important to early and accurate detection and appropriate management. Diagnosis of CAD include clinical examination, noninvasive techniques such as biochemical testing, a resting ECG, possibly ambulatory ECG monitoring, resting echocardiography, chest X-ray in selected patients; and catheterization. Managements of CAD patients include lifestyle modification, control of CAD risk factors, pharmacologic therapy, and patient education. Revascularization consists of percutaneous coronary angioplasty and coronary artery bypass grafting. Cardiac rehabilitation should be considered in all patients with CAD. This comprehensive review highlights strategies of management in patients with CAD.

  14. PLACENTAL GROWTH FACTOR AND CORONARY NEOANGIOGENESIS IN CORONARY HEART DISEASE

    Directory of Open Access Journals (Sweden)

    M. V. Tulikov

    2013-01-01

    Full Text Available Neoangiogenesis in coronary heart disease is a protective reaction aimed to improve ischemic myocardial perfusion, by increasing the number and size of arterial collaterals. Placental growth factor (PlGF is one of the key peptides regulating angiogenic processes in atherosclerosis. In particular, a number of investigators have shown that injection of recombinant PlGF into the system or regional blood flow can stimulate neoangiogenesis. On the other hand, there is evidence confirming the involvement of PlGF in the progression of atherosclerosis and in the development of acute coronary syndrome. In this connection, the problem of investigating the efficiency and safety of possible use of PlGF preparations, as well as its place in the diagnosis of coronary heart disease and acute coronary syndrome remains urgent

  15. Comparison of Quantitative Wall Motion Analysis and Strain For Detection Of Coronary Stenosis With Three-Dimensional Dobutamine Stress Echocardiography

    Science.gov (United States)

    Parker, Katherine M.; Clark, Alexander P.; Goodman, Norman C.; Glover, David K.; Holmes, Jeffrey W.

    2015-01-01

    Background Quantitative analysis of wall motion from three-dimensional (3D) dobutamine stress echocardiography (DSE) could provide additional diagnostic information not available from qualitative analysis. In this study we compare the effectiveness of 3D fractional shortening (3DFS), a measure of wall motion computed from 3D echocardiography (3DE), to strain and strain rate measured with sonomicrometry for detecting critical stenoses during DSE. Methods Eleven open-chest dogs underwent DSE both with and without a critical stenosis. 3DFS was measured from 3DE images acquired at peak stress. 3DFS was normalized by subtracting average 3DFS during control peak stress (Δ3DFS). Strains in the perfusion defect (PD) were measured from sonomicrometry, and PD size and location were measured with microspheres. Results A Δ3DFS abnormality indicated the presence of a critical stenosis with high sensitivity and specificity (88% and 100%, respectively), and Δ3DFS abnormality size correlated with PD size (R2=0.54). The sensitivity and specificity for Δ3DFS was similar to that for area strain (88%, 100%) and circumferential strain and strain rate (88%, 92% and 88%, 86%, respectively), while longitudinal strain and strain rate were less specific. Δ3DFS correlated significantly with both coronary flow reserve (R2=0.71) and PD size (R2=0.97), while area strain correlated with PD size only (R2=0.67), and other measures were not significantly correlated with flow reserve or PD size. Conclusion Quantitative wall motion analysis using Δ3DFS is effective for detecting critical stenoses during DSE, performing similarly to 3D strain, and provides potentially useful information on the size and location of a perfusion defect. PMID:24815588

  16. Design and rationale of the MR-INFORM study: stress perfusion cardiovascular magnetic resonance imaging to guide the management of patients with stable coronary artery disease

    Directory of Open Access Journals (Sweden)

    Hussain Shazia T

    2012-09-01

    Full Text Available Abstract Background In patients with stable coronary artery disease (CAD, decisions regarding revascularisation are primarily driven by the severity and extent of coronary luminal stenoses as determined by invasive coronary angiography. More recently, revascularisation decisions based on invasive fractional flow reserve (FFR have shown improved event free survival. Cardiovascular magnetic resonance (CMR perfusion imaging has been shown to be non-inferior to nuclear perfusion imaging in a multi-centre setting and superior in a single centre trial. In addition, it is similar to invasively determined FFR and therefore has the potential to become the non-invasive test of choice to determine need for revascularisation. Trial design The MR-INFORM study is a prospective, multi-centre, randomised controlled non-inferiority, outcome trial. The objective is to compare the efficacy of two investigative strategies for the management of patients with suspected CAD. Patients presenting with stable angina are randomised into two groups: 1 The FFR-INFORMED group has subsequent management decisions guided by coronary angiography and fractional flow reserve measurements. 2 The MR-INFORMED group has decisions guided by stress perfusion CMR. The primary end-point will be the occurrence of major adverse cardiac events (death, myocardial infarction and repeat revascularisation at one year. Clinical trials.gov identifier NCT01236807. Conclusion MR INFORM will assess whether an initial strategy of CMR perfusion is non-inferior to invasive angiography supplemented by FFR measurements to guide the management of patients with stable coronary artery disease. Non-inferiority of CMR perfusion imaging to the current invasive reference standard (FFR would establish CMR perfusion imaging as an attractive non-invasive alternative to current diagnostic pathways.

  17. Maturation of human oocytes in vitro

    Directory of Open Access Journals (Sweden)

    Mojca Čižek-Sajko

    2007-01-01

    Full Text Available Background: Immature oocyte retrieval followed by in vitro maturation is a promising infertility treatment option. In patients with morphologically normal ovaries and regular menstrual cycles and in patients with polycystic ovary syndrome (PCOS we attempted to assess the success of oocyte in vitro maturation in in vitro fertilization (IVF procedures.Methods: Retrospectively we analyzed 87 IVF procedures with in vitro maturation of oocytes carried out in 73 infertile couples treated at the Maribor Teaching Hospital. We compared the success following three different hormone priming protocols: regular cycling patients with normal ovaries and without hormone priming (Group A, n = 27; patients with PCOS and hormone priming with follitropin (follicle stimulating hormone, FSH (Group B, n = 22; patients with PCOS and hormone priming with human chorionic gonadotrophin (hCG (Group C, n = 38. Success of the procedure was evaluated on the basis of the ability of oocytes to mature, fertilize and develop into embryos, and on the basis of the quality of embryos and their ability to implant in the uterus.Results: In regular cycling patients with normal ovaries (n = 27 we obtained a significantly lower number of immature oocytes (3.2 ± 2.5 compared with patients with PCOS and FSH priming (11.7 ± 7.2 or those with PCOS and hCG priming (10.4 ± 7.2. The oocyte maturation rate, the fertilization rate and the embryo cleavage rate were as follows: in Group A 57.7 %, 63.2 % and 91.7 %, in Group B 57.6 %, 66.2 % and 90.0 %, and in Group C 58.0 %, 66.2 % and 91.0 % (the differences between groups were not statistically significant. Six pregnancies were recorded only in patients with PCOS. The pregnancy rate per embryo transfer was 1/20 (5.0 % in patients with FSH priming, and 5/33 (15.2 % in patients with hCG priming.Conclusions: Oocyte in vitro maturation is successful in patients with normal ovaries and regular menstrual cycle as well as in those with polycystic

  18. Coronary angiography using synchrotron radiation

    International Nuclear Information System (INIS)

    Akatsuka, Takao; Hiranaka, Yukio; Takeda, Tohru; Hyodo, Kazuyuki.

    1990-01-01

    Invasive coronary angiography is the imaging technique of choice for diagnosis of ischemic heart disease. Recently, the application of synchrotron radiation in coronary angiography has been investigated in the world, with the aim of developing the noninvasive technique for visualizing the heart. In this article, backgrounds and present situation of coronary angiography using synchrotron radiation are reviewed. Firstly, visual imaging techniques of the cardiovascular system are discussed in terms of angiography and digital subtraction angiography (DSA). Conventional temporal, energy, and hybrid subtraction modes used in DSA are referred to. Secondly, the application of synchrotron radiation is presented, focusing on the property of synchrotron radiation and K-edge subtraction angiography. Two kinds of synchrotron radiation beam methods are outlined. Interpretation of image data and various subtraction procedures remain unestablished. There is much to be done before coronary angiography using synchrotron radiation comes into a clinical practice. (N.K.)

  19. Depression following acute coronary syndrome

    DEFF Research Database (Denmark)

    Joergensen, Terese Sara Hoej; Maartensson, Solvej; Ibfelt, Else Helene

    2016-01-01

    PURPOSE: Depression is common following acute coronary syndrome, and thus, it is important to provide knowledge to improve prevention and detection of depression in this patient group. The objectives of this study were to examine: (1) whether indicators of stressors and coping resources were risk...... factors for developing depression early and later after an acute coronary syndrome and (2) whether prior depression modified these associations. METHODS: The study was a register-based cohort study, which includes 87,118 patients with a first time diagnosis of acute coronary syndrome during the period...... 2001-2009 in Denmark. Cox regression models were used to analyse hazard ratios (HRs) for depression. RESULTS: 1.5 and 9.5 % develop early (≤30 days) and later (31 days-2 years) depression after the acute coronary syndrome. Among all patients with depression, 69.2 % had first onset depression, while 30...

  20. Coronary Computed Tomography Angiography (CTA)

    Science.gov (United States)

    ... coronary arteries, may also be administered as a tablet or spray underneath your tongue. While lying on ... the scanner at one time such as with MRI. If an intravenous contrast material is used, you ...

  1. Pronounced Coronary Arteriosclerosis in Cirrhosis

    DEFF Research Database (Denmark)

    Danielsen, Karen V; Wiese, Signe; Hove, Jens

    2018-01-01

    factors including smoking, type 2 diabetes, hypertension, gender, or hypercholesterolemia. Coronary artery calcium-score was associated with diastolic dysfunction, lateral e´ (p = 0.025), but not with other markers of cardiac dysfunction. During a median follow-up of 25 months 12 patients (21%) died......BACKGROUND: The relation between excessive alcohol consumption and coronary arteriosclerosis has remained controversial. The etiology of cirrhosis has been considered a substantial risk factor for development of arteriosclerotic lesions. The coronary artery calcium-score derived from coronary CT...... and women: 136 vs. 0 HU; p alcohol-related cirrhosis was significantly higher than in nonalcohol-related cirrhosis (362 vs. 46 HU, p 

  2. Diagnostic accuracy of coronary CT angiography using 3{sup rd}-generation dual-source CT and automated tube voltage selection: Clinical application in a non-obese and obese patient population

    Energy Technology Data Exchange (ETDEWEB)

    Mangold, Stefanie [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Eberhard-Karls University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Wichmann, Julian L. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Schoepf, U.J. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States); Caruso, Damiano [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); University of Rome ' ' Sapienza' ' , Department of Radiological Sciences, Oncology and Pathology, Rome (Italy); Tesche, Christian [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Heart Centre Munich-Bogenhausen, Department of Cardiology, Munich (Germany); Steinberg, Daniel H.; Bayer, Richard R. [Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States); Varga-Szemes, Akos; Stubenrauch, Andrew C.; Biancalana, Matthew; De Cecco, Carlo N. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Nikolaou, Konstantin [Eberhard-Karls University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany)

    2017-06-15

    To investigate diagnostic accuracy of 3{sup rd}-generation dual-source CT (DSCT) coronary angiography in obese and non-obese patients. We retrospectively analyzed 76 patients who underwent coronary CT angiography (CCTA) and invasive coronary angiography. Prospectively ECG-triggered acquisition was performed with automated tube voltage selection (ATVS). Patients were dichotomized based on body mass index in groups A (<30 kg/m{sup 2}, n = 37) and B (≥30 kg/m{sup 2}, n = 39) and based on tube voltage in groups C (<120 kV, n = 46) and D (120 kV, n = 30). Coronary arteries were assessed for significant stenoses (≥50 % luminal narrowing) and diagnostic accuracy was calculated. Per-patient overall sensitivity, specificity, positive predictive value, negative predictive value (NPV) and accuracy were 96.9 %, 95.5 %, 93.9 %, 97.7 % and 96.1 %, respectively. Sensitivity and NPV were lower in groups B and D compared to groups A and C, but no statistically significant differences were observed (group A vs. B: sensitivity, 100.0 % vs. 93.3 %, p = 0.9493; NPV, 100 % vs. 95.5 %, p = 0.9812; group C vs. D: sensitivity, 100.0 % vs. 92.3 %, p = 0.8462; NPV, 100.0 % vs. 94.1 %, p = 0.8285). CCTA using 3{sup rd}-generation DSCT and (ATVS) provides high diagnostic accuracy in both non-obese and obese patients. (orig.)

  3. Diagnostic accuracy of coronary CT angiography using 3"r"d-generation dual-source CT and automated tube voltage selection: Clinical application in a non-obese and obese patient population

    International Nuclear Information System (INIS)

    Mangold, Stefanie; Wichmann, Julian L.; Schoepf, U.J.; Caruso, Damiano; Tesche, Christian; Steinberg, Daniel H.; Bayer, Richard R.; Varga-Szemes, Akos; Stubenrauch, Andrew C.; Biancalana, Matthew; De Cecco, Carlo N.; Nikolaou, Konstantin

    2017-01-01

    To investigate diagnostic accuracy of 3"r"d-generation dual-source CT (DSCT) coronary angiography in obese and non-obese patients. We retrospectively analyzed 76 patients who underwent coronary CT angiography (CCTA) and invasive coronary angiography. Prospectively ECG-triggered acquisition was performed with automated tube voltage selection (ATVS). Patients were dichotomized based on body mass index in groups A (<30 kg/m"2, n = 37) and B (≥30 kg/m"2, n = 39) and based on tube voltage in groups C (<120 kV, n = 46) and D (120 kV, n = 30). Coronary arteries were assessed for significant stenoses (≥50 % luminal narrowing) and diagnostic accuracy was calculated. Per-patient overall sensitivity, specificity, positive predictive value, negative predictive value (NPV) and accuracy were 96.9 %, 95.5 %, 93.9 %, 97.7 % and 96.1 %, respectively. Sensitivity and NPV were lower in groups B and D compared to groups A and C, but no statistically significant differences were observed (group A vs. B: sensitivity, 100.0 % vs. 93.3 %, p = 0.9493; NPV, 100 % vs. 95.5 %, p = 0.9812; group C vs. D: sensitivity, 100.0 % vs. 92.3 %, p = 0.8462; NPV, 100.0 % vs. 94.1 %, p = 0.8285). CCTA using 3"r"d-generation DSCT and (ATVS) provides high diagnostic accuracy in both non-obese and obese patients. (orig.)

  4. Physiologic assessment of coronary artery fistula

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, N.C.; Beauvais, J. (Creighton Univ., Omaha, NE (USA))

    1991-01-01

    Coronary artery fistula is an uncommon clinical entity. The most common coronary artery fistula is from the right coronary artery to the right side of the heart, and it is less frequent to the pulmonary artery. The effect of a coronary artery fistula may be physiologically significant because of the steal phenomenon resulting in coronary ischemia. Based on published reports, it is recommended that patients with congenital coronary artery fistulas be considered candidates for elective surgical correction to prevent complications including development of congestive heart failure, angina, subacute bacterial endocarditis, myocardial infarction, and coronary aneurysm formation with rupture or embolization. A patient is presented in whom treadmill-exercise thallium imaging was effective in determining the degree of coronary steal from a coronary artery fistula, leading to successful corrective surgery.

  5. Physiologic assessment of coronary artery fistula

    International Nuclear Information System (INIS)

    Gupta, N.C.; Beauvais, J.

    1991-01-01

    Coronary artery fistula is an uncommon clinical entity. The most common coronary artery fistula is from the right coronary artery to the right side of the heart, and it is less frequent to the pulmonary artery. The effect of a coronary artery fistula may be physiologically significant because of the steal phenomenon resulting in coronary ischemia. Based on published reports, it is recommended that patients with congenital coronary artery fistulas be considered candidates for elective surgical correction to prevent complications including development of congestive heart failure, angina, subacute bacterial endocarditis, myocardial infarction, and coronary aneurysm formation with rupture or embolization. A patient is presented in whom treadmill-exercise thallium imaging was effective in determining the degree of coronary steal from a coronary artery fistula, leading to successful corrective surgery

  6. Asymbiotic in vitro seed propagation of Dendrobium.

    Science.gov (United States)

    Teixeira da Silva, Jaime A; Tsavkelova, Elena A; Ng, Tzi Bun; Parthibhan, S; Dobránszki, Judit; Cardoso, Jean Carlos; Rao, M V; Zeng, Songjun

    2015-10-01

    The ability to germinate orchids from seeds in vitro presents a useful and viable method for the propagation of valuable germplasm, maintaining the genetic heterogeneity inherent in seeds. Given the ornamental and medicinal importance of many species within the genus Dendrobium, this review explores in vitro techniques for their asymbiotic seed germination. The influence of abiotic factors (such as temperature and light), methods of sterilization, composition of basal media, and supplementation with organic additives and plant growth regulators are discussed in context to achieve successful seed germination, protocorm formation, and further seedling growth and development. This review provides both a basis for the selection of optimal conditions, and a platform for the discovery of better ones, that would allow the development of new protocols and the exploration of new hypotheses for germination and conservation of Dendrobium seeds and seedlings.

  7. Inhibition of acetylcholine synthesis in vitro

    International Nuclear Information System (INIS)

    O-Neill, J.J.; Capacio, B.; Doukas, P.H.; Leech, R.; Ricciardi, F.; Sterling, G.H.

    1986-01-01

    In order to better understand diseases that stem from deficiencies in cholinergic activity, reproducible in vitro and in vivo models displaying cholinergic hypofunction are desirable. This necessitates the availability of specific inhibitors. This paper examines the design, synthesis and evaluation of quinuclidinyl compounds with structural features previously reported, but with certain key differences. Structure activity studies with in vitro assay systems are presented. In a few studies, choline was held constant and acetyl-CoA concentration was varied, but with a constant amount of ( 14 C) - acetyl CoA. Acetylcholine synthesis and CO 2 production from labelled glucose were measured in cerebral cortex slices from male rats after decapitation. The nanomoles of ACh and CO 2 produced from ( 14 C) -glucose were calculated from glucose specific activity. Results are presented

  8. Human rights to in vitro fertilization.

    Science.gov (United States)

    Zegers-Hochschild, Fernando; Dickens, Bernard M; Dughman-Manzur, Sandra

    2013-10-01

    The Inter-American Court of Human Rights (the Court) has ruled that the Supreme Court of Costa Rica's judgment in 2000 prohibiting in vitro fertilization (IVF) violated the human right to private and family life, the human right to found and raise a family, and the human right to non-discrimination on grounds of disability, financial means, or gender. The Court's conclusions of violations contrary to the American Convention on Human Rights followed from its ruling that, under the Convention, in vitro embryos are not "persons" and do not possess a right to life. Accordingly, the prohibition of IVF to protect embryos constituted a disproportionate and unjustifiable denial of infertile individuals' human rights. The Court distinguished fertilization from conception, since conception-unlike fertilization-depends on an embryo's implantation in a woman's body. Under human rights law, legal protection of an embryo "from conception" is inapplicable between its creation by fertilization and completion of its implantation in utero. © 2013.

  9. Bovine in vitro embryo production : An overview

    Directory of Open Access Journals (Sweden)

    V. S. Suthar

    Full Text Available Dairy industry perfected the application of the first reproductive biotechnology, i.e. artificial insemination (AI - a great success story and also remains the user of embryo transfer technology (ETT. In addition, recently the researchers taking interest to embraced the field of Transvaginal OocyteRecovery (TVOR and in vitro production (IVEP of embryos. IVF provides the starting point for the generation of reproductive material for a number of advanced reproduction techniques including sperm microinjection and nuclear transfer (cloning. In several countries commercial IVF facilities are already being employed by cattle ET operators. Various research groups have reported on modification of TVOR technique to give greater efficiency. Much research is still needed in domestic animal (Especially Indian species on mechanisms controlling embryo development and on development of totally in vitro system for embryo culture. [Vet World 2009; 2(12.000: 478-479`

  10. In vitro modification of Candida albicans invasiveness.

    Science.gov (United States)

    Fontenla de Petrino, S E; de Jorrat, M E; Sirena, A; Valdez, J C; Mesón, O

    1986-05-01

    Candida albicans produces germ-tubes (GT) when it is incubated in animal or human serum. This dimorphism is responsible for its invasive ability. The purpose of the present paper is (1) to evaluate the ability of rat peritoneal macrophages to inhibit GT production of ingested Candida albicans, obtained from immunized rats and then activated in vitro with Candida-induced lymphokines; (2) to determinate any possible alteration of phagocytic and candidacidal activities. The phagocytes were obtained from rats immunized with viable C. albicans. Some of them were exposed to Candida-induced lymphokines in order to activate the macrophages in vitro. The monolayers of activated, immune and normal macrophages were infected with a C. albicans suspension during 4 hr. Activated macrophages presented not only the highest phagocytic and candidacidal activities but a noticeable inhibition of GT formation and incremented candidacidal activity.

  11. In vitro propagation of endangered Dianthus taxa

    Directory of Open Access Journals (Sweden)

    Marković Marija

    2015-01-01

    Full Text Available The review of recent researches regarding the in vitro culture of 30 endangered Dianthus taxa is presented in this paper. Various in vitro protocols developed for selected rare and threatened Dianthus taxa are analysed in order to provide a useful synthesis of the data obtained with the main principles, techniques and recommendations for futher research and practice. The recapitulated data presented in this review can be used as a tool for the micropropagation of other endangered Dianthus taxa, enabling their propagation and obtaining a sufficient amount of plants for reintroduction. In addition, the obtained results represent the basis for ex situ conservation of the investigated taxa, especially for medium-term and long-term conservation (cryopreservation. [Projekat Ministarstva nauke Republike Srbije, br. 43007

  12. T Cell Genesis: In Vitro Veritas Est?

    OpenAIRE

    Brauer, Patrick M.; Singh, Jastaranpreet; Xhiku, Sintia; Zúñiga-Pflücker, Juan Carlos

    2016-01-01

    T cells, as orchestrators of the adaptive immune response, serve important physiological and potentially therapeutic roles, for example in cancer immunotherapy. T cells are readily isolated from patients; however, the yield of antigen-specific T cells is limited, thus making their clinical use challenging. Therefore, the generation of T lymphocytes from hematopoietic stem/progenitor cells (HSPCs) and human pluripotent stem cells (PSCs) in vitro provides an attractive method for large-scale pr...

  13. Comparative properties of feline coronaviruses in vitro.

    OpenAIRE

    McKeirnan, A J; Evermann, J F; Davis, E V; Ott, R L

    1987-01-01

    Two feline coronaviruses were characterized to determine their biological properties in vitro and their antigenic relatedness to a previously recognized feline infectious peritonitis virus and canine coronavirus. The viruses, designated WSU 79-1146 and WSU 79-1683, were shown to have comparable growth curves with the prototype feline infectious peritonitis virus. Treatment of the feline infectious peritonitis virus strains with 0.25% trypsin indicated that they were relatively resistant to pr...

  14. Correlation between coronary computed tomographic angiography and fractional flow reserve

    DEFF Research Database (Denmark)

    Kristensen, Thomas Skaarup; Engstrøm, Thomas; Kelbæk, Henning

    2010-01-01

    Coronary CT angiography (CCTA) has become an important modality to evaluate the presence of coronary artery disease. Coronary artery stenosis of intermediate severity remains a therapeutic dilemma. Measurement of fractional flow reserve (FFR) during coronary angiography is the most established...

  15. Propagação in vitro de Sacha inchi In vitro propagation of Sacha inchi

    Directory of Open Access Journals (Sweden)

    Stevan Ricardo Bordignon

    2012-07-01

    Full Text Available O objetivo do presente trabalho foi avaliar in vitro a relação auxina:citocinina a fim de obter propágulos nos segmentos distintos do epicótilo e hipocótilo de sementes germinadas in vitro de Sacha inchi (Plukenetia volubilis Linneo. Os segmentos apical (A, mediano (B e o basal (C foram introduzidos em meio de cultivo MS, semi sólido (2,0g L-1 Phytagel, suplementado com vitaminas de MS, sacarose (30,0g L-1 e submetidos a três doses da auxina ácido indolbutírico - IBA (0; 0,1; 0,5mg L-1, associadas a quatro doses da citocinina benzilaminopurina - BAP (0; 0,1; 0,5; 1,0mg L-1, totalizando 36 tratamentos. Após nove semanas de cultivo in vitro, o segmento apical (A apresentou formação de brotações por organogênese direta nas concentrações de 0,5 e 1,0 de BAP, associado a 0,0 e 0,1 de IBA. O emprego do cultivo in vitro é viável na produção de mudas, utilizando como explante a região apical de sementes germinadas in vitro.The aim of this study was to perform an in vitro evaluation of the auxin:cytokinine ratio in different segments of the epicotyl and hypocotyl of Sacha inchi (Plukenetia volubilis Linneo seeds germinated in vitro. The segments apical (A, median (B and basal (C were introduced into semi-solid MS culture medium (2.0g L-1 Phytagel, supplemented with MS vitamins, sucrose (30.0g L-1 and submitted to three doses of auxin indolebutyric acid - IBA (0; 0.1; 0.5mg L-1, associated with four doses of the cytokinine benzylaminopurine - BAP (0; 0.1; 0.5; 1.0mg L-1, totaling 36 treatments. After nine weeks of in vitro cultivation, the apical segment (A presented shoot formation by direct organogenesis at the concentrations of 0.5 and 1.0 of BAP associated with 0.0 and 0.1 of IBA. It is feasible to use in vitro cultivation with the apical region of seeds germinated in vitro used as explants.

  16. Clarifying mammalian RISC assembly in vitro

    Directory of Open Access Journals (Sweden)

    Metzler David

    2011-04-01

    Full Text Available Abstract Background Argonaute, the core component of the RNA induced silencing complex (RISC, binds to mature miRNAs and regulates gene expression at transcriptional or post-transcriptional level. We recently reported that Argonaute 2 (Ago2 also assembles into complexes with miRNA precursors (pre-miRNAs. These Ago2:pre-miRNA complexes are catalytically active in vitro and constitute non-canonical RISCs. Results The use of pre-miRNAs as guides by Ago2 bypasses Dicer activity and complicates in vitro RISC reconstitution. In this work, we characterized Ago2:pre-miRNA complexes and identified RNAs that are targeted by miRNAs but not their corresponding pre-miRNAs. Using these target RNAs we were able to recapitulate in vitro pre-miRNA processing and canonical RISC loading, and define the minimal factors required for these processes. Conclusions Our results indicate that Ago2 and Dicer are sufficient for processing and loading of miRNAs into RISC. Furthermore, our studies suggest that Ago2 binds primarily to the 5'- and alternatively, to the 3'-end of select pre-miRNAs.

  17. Intracranial cerebral artery stenosis with associated coronary artery and extracranial carotid artery stenosis in Turkish patients

    Energy Technology Data Exchange (ETDEWEB)

    Alkan, Ozlem [Department of Radiology, Baskent University, Faculty of Medicine, Ankara (Turkey)], E-mail: yalinozlem@hotmail.com; Kizilkilic, Osman; Yildirim, Tulin [Department of Radiology, Baskent University, Faculty of Medicine, Ankara (Turkey); Atalay, Hakan [Department of Cardiovascular Surgery, Baskent University, Faculty of Medicine, Ankara (Turkey)

    2009-09-15

    Purpose: Although it has been demonstrated that there is a high prevalence of extracranial carotid artery stenosis (ECAS) in patients with severe coronary artery disease, intracranial cerebral artery stenosis (ICAS) is rarely mentioned. We evaluated the prevalence of ICAS in patients with ECAS having elective coronary artery bypass grafting (CABG) surgery to determine the relations between ICAS, ECAS and atherosclerotic risk factors. Methods: We retrospectively reviewed the digital subtraction angiography findings of 183 patients with ECAS {>=} 50% preparing for CABG surgery. The analyses focused on the intracranial or extracranial location and degree of the stenosis. The degree of extracranial stenoses were categorized as normal, <50%, 50-69%, 70-89%, and 90-99% stenosis and occluded. The degree of intracranial stenosis was classified as normal or {<=}25%, 25-49%, and {>=}50% stenosis and occluded. Traditional atherosclerotic risk factors were recorded. Results: ECAS < 70% in 42 patients and ECAS {>=} 70% in 141 patients. ICAS was found in 51 patients and ICAS {>=} 50% in 30 patients. Regarding risk factors, we found hypertension in 135 patients, diabetes mellitus in 91 patients, hyperlipidemia in 84 patients, and smoking in 81 patients. No risk factor was significant predictors of intracranial atherosclerosis. The severity of ICAS was not significantly associated with that of the ECAS. Conclusions: We found ICAS in 27.8% of the patients with ECAS > 50% on digital subtraction angiography preparing for CABG. Therefore a complete evaluation of the neck vessels with magnetic resonance or catheter angiography seems to be indicated as well as intracranial circulation for the risk assessment of CABG.

  18. Coronary artery bypass graft imaging using ECG-gated multislice computed tomography: Comparison with catheter angiography

    International Nuclear Information System (INIS)

    Moore, R.K.G.; Sampson, C.; MacDonald, S.; Moynahan, C.; Groves, D.; Chester, M.R.

    2005-01-01

    AIM: To compare the value of multislice computerized tomography (MSCT) in imaging coronary artery bypass grafts (CABGs) by direct quantitative comparison with standard invasive angiography. METHODS: Using MSCT, 50 consecutive patients who had previously undergone CABG surgery and had recently undergone invasive angiography for recurrent angina pectoris, were studied further using MSCT after intravenous injection of non-ionic contrast agent; cardiac imaging was performed during a single breath-hold. Graft anatomy was quantified, using both quantitative coronary angiography (QCA) and MSCT, by different investigators blinded to each other. Reproducibility was quantified using the standard error of the measurement expressed as a percentage in log-transformed values (CV%) and intraclass correlation (ICC). RESULTS: All 150 grafts were imaged using MSCT; only 4 patent grafts were not imaged using selective angiography. Good agreement was achieved between MSCT and QCA on assessment of proximal anastomoses (CV% 25.2, ICC 0.84), mid-vessel luminal diameter (CV% 15.5, ICC 0.91) and aneurysmal dilations (CV% 14.3). Reasonable agreement was reached on assessment of distal anastomoses (CV% 26.7, ICC 0.66) and categorization of distal run-off (ICC 0.73). Good agreement was observed for stenoses of over 50% luminal loss (CV% 8.7, ICC 0.97) but agreement on assessment of less severe lesions was poor (CV% 208.7, ICC 0.51). CONCLUSION: This study demonstrates that CABGs can be quantitatively evaluated using MSCT, and that significant lesions present in all CABG segments can be reliably identified. Agreement between MSCT and QCA for lesions of less than 50% luminal loss was poor

  19. Coronary artery bypass graft imaging using ECG-gated multislice computed tomography: Comparison with catheter angiography

    Energy Technology Data Exchange (ETDEWEB)

    Moore, R.K.G. [Cardiothoracic Centre, Liverpool (United Kingdom)]. E-mail: moore@roger.go-legend.net; Sampson, C. [Cardiothoracic Centre, Liverpool (United Kingdom); MacDonald, S. [Cardiothoracic Centre, Liverpool (United Kingdom); Moynahan, C. [Cardiothoracic Centre, Liverpool (United Kingdom); Groves, D. [National Refractory Angina Centre, Liverpool (United Kingdom); Chester, M.R. [National Refractory Angina Centre, Liverpool (United Kingdom)

    2005-09-01

    AIM: To compare the value of multislice computerized tomography (MSCT) in imaging coronary artery bypass grafts (CABGs) by direct quantitative comparison with standard invasive angiography. METHODS: Using MSCT, 50 consecutive patients who had previously undergone CABG surgery and had recently undergone invasive angiography for recurrent angina pectoris, were studied further using MSCT after intravenous injection of non-ionic contrast agent; cardiac imaging was performed during a single breath-hold. Graft anatomy was quantified, using both quantitative coronary angiography (QCA) and MSCT, by different investigators blinded to each other. Reproducibility was quantified using the standard error of the measurement expressed as a percentage in log-transformed values (CV%) and intraclass correlation (ICC). RESULTS: All 150 grafts were imaged using MSCT; only 4 patent grafts were not imaged using selective angiography. Good agreement was achieved between MSCT and QCA on assessment of proximal anastomoses (CV% 25.2, ICC 0.84), mid-vessel luminal diameter (CV% 15.5, ICC 0.91) and aneurysmal dilations (CV% 14.3). Reasonable agreement was reached on assessment of distal anastomoses (CV% 26.7, ICC 0.66) and categorization of distal run-off (ICC 0.73). Good agreement was observed for stenoses of over 50% luminal loss (CV% 8.7, ICC 0.97) but agreement on assessment of less severe lesions was poor (CV% 208.7, ICC 0.51). CONCLUSION: This study demonstrates that CABGs can be quantitatively evaluated using MSCT, and that significant lesions present in all CABG segments can be reliably identified. Agreement between MSCT and QCA for lesions of less than 50% luminal loss was poor.

  20. Endogenous testosterone attenuates neointima formation after moderate coronary balloon injury in male swine.

    Science.gov (United States)

    Tharp, Darla L; Masseau, Isabelle; Ivey, Jan; Ganjam, Venkataseshu K; Bowles, Douglas K

    2009-04-01

    Previous studies from our laboratory have demonstrated that testosterone increases coronary smooth muscle protein kinase C delta (PKC delta) both in vivo and in vitro and inhibits coronary smooth muscle proliferation by inducing G(0)/G(1) cell cycle arrest in a PKC delta-dependent manner. The purpose of the present study was to determine whether endogenous testosterone limits coronary neointima (NI) formation in a porcine model of post-angioplasty restenosis. Sexually mature, male Yucatan miniature swine were either left intact (IM), castrated (CM), or castrated with testosterone replacement (CMT; Androgel, 10 mg/day). Angioplasty was performed in both the left anterior descending and left circumflex coronary arteries with balloon catheter overinflation to induce either moderate (1.25-1.3 x diameter; 3 x 30 s) or severe (1.4x diameter; 3 x 30 s) injury, and animals were allowed to recover for either 10 or 28 days. Injured coronary sections were dissected, fixed, stained (Verheoff-Van Gieson, Ki67, PKC delta, p27), and analysed. Vessels without internal elastic laminal rupture were excluded. Following moderate injury, intimal area, intima-to-media ratio (I/M), and I/M normalized to rupture index (RI) were increased in CM compared with IM and CMT. RI, medial area, and intimal/medial thickness (IMT) were not different between groups. NI formation was inversely related to serum testosterone concentration. Conversely, following severe injury, there were no significant differences between the groups. Testosterone inhibited proliferation and stimulated PKC delta and p27(kip1) expression during NI formation (10 days post-injury). These findings demonstrate that endogenous testosterone limits coronary NI formation in male swine and provides support for a protective role for testosterone in coronary vasculoproliferative diseases, such as restenosis and atherosclerosis.

  1. In vitro metabolism and permeation studies in rat jejunum

    DEFF Research Database (Denmark)

    Gammelgaard, Bente; Jensen, K; Steffansen, B

    1999-01-01

    The purpose of these studies was to compare the in vitro absorption of two inorganic chromium(III) compounds: chromium chloride and chromium nitrate, with organic chromium(III)-picolinate; and to investigate if any in vitro metabolism of chromium(VI) takes place. The in vitro metabolism studies...

  2. 21 CFR 801.119 - In vitro diagnostic products.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false In vitro diagnostic products. 801.119 Section 801...) MEDICAL DEVICES LABELING Exemptions From Adequate Directions for Use § 801.119 In vitro diagnostic products. A product intended for use in the diagnosis of disease and which is an in vitro diagnostic...

  3. 21 CFR 201.119 - In vitro diagnostic products.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false In vitro diagnostic products. 201.119 Section 201...) DRUGS: GENERAL LABELING Exemptions From Adequate Directions for Use § 201.119 In vitro diagnostic products. (a) “In vitro diagnostic products” are those reagents, instruments and systems intended for use...

  4. Coronary artery anomalies in Turner Syndrome.

    Science.gov (United States)

    Viuff, Mette H; Trolle, Christian; Wen, Jan; Jensen, Jesper M; Nørgaard, Bjarne L; Gutmark, Ephraim J; Gutmark-Little, Iris; Mortensen, Kristian H; Gravholt, Claus Højbjerg; Andersen, Niels H

    Congenital heart disease, primarily involving the left-sided structures, is often seen in patients with Turner Syndrome. Moreover, a few case reports have indicated that coronary anomalies may be more prevalent in Turner Syndrome than in the normal population. We therefore set out to systematically investigate coronary arterial anatomy by computed tomographic coronary angiography (coronary CTA) in Turner Syndrome patients. Fifty consecutive women with Turner Syndrome (mean age 47 years [17-71]) underwent coronary CTA. Patients were compared with 25 gender-matched controls. Coronary anomaly was more frequent in patients with Turner Syndrome than in healthy controls [20% vs. 4% (p = 0.043)]. Nine out of ten abnormal cases had an anomalous left coronary artery anatomy (absent left main trunk, n = 7; circumflex artery originating from the right aortic sinus, n = 2). One case had a tubular origin of the right coronary artery above the aortic sinus. There was no correlation between the presence of coronary arterial anomalies and karyotype, bicuspid aortic valve, or other congenital heart defects. Coronary anomalies are highly prevalent in Turner Syndrome. The left coronary artery is predominantly affected, with an absent left main coronary artery being the most common anomaly. No hemodynamically relevant coronary anomalies were found. Copyright © 2016 Society of Cardiovascular Computed Tomography. All rights reserved.

  5. Investigation on biological properties of tacrolimus-loaded poly(1,3-trimethylene carbonate) in vitro

    Science.gov (United States)

    Hou, Ruixia; Wu, Leigang; Wang, Jin; Huang, Nan

    2010-06-01

    The drug-eluting stents have been regarded as a milestone in inhibiting the restenosis of coronary arteries. However, adverse reactions caused by bare-metal stents and non-biodegradable polymer coatings may result in some clinical problems. In this study, a new tacrolimus-eluting stent coated with biodegradable poly(1,3-trimethylene carbonate) (PTMC) is developed. The structures are characterized by Fourier transform infrared (FTIR) analysis, and the wettability is measured by contact angle assay. The biological behaviors are evaluated by the in vitro platelets adhesion test, APTT test, the human umbilical cord artery smooth muscle cells (HUCASMCs), 4',6-diamidine-2-phenylindole (DAPI) and actin immunofluorescence staining, MTT colorimetric assay. These results show that after blending tacrolimus into PTMC, the anticoagulant behavior is improved, and the adhesion and proliferation of HUCASMCs on samples are inhibited. This work aims to find one kind of surface erosion biodegradable polymers that can be applied as drug-eluting stent coatings.

  6. Early results of coronary artery bypass grafting with coronary endarterectomy for severe coronary artery disease

    Directory of Open Access Journals (Sweden)

    Toischer Karl

    2009-09-01

    Full Text Available Abstract Background Despite the existence of controversial debates on the efficiency of coronary endarterectomy (CE, it is still used as an adjunct to coronary artery bypass grafting (CABG. This is particularly true in patients with endstage coronary artery disease. Given the improvements in cardiac surgery and postoperative care, as well as the rising number of elderly patient with numerous co-morbidities, re-evaluating the pros and cons of this technique is needed. Methods Patient demographic information, operative details and outcome data of 104 patients with diffuse calcified coronary artery disease were retrospectively analyzed with respect to functional capacity (NYHA, angina pectoris (CCS and mortality. Actuarial survival was reported using a Kaplan-Meyer analysis. Results Between August 2001 and March 2005, 104 patients underwent coronary artery bypass grafting (CABG with adjunctive coronary endarterectomy (CE in the Department of Thoracic-, Cardiac- and Vascular Surgery, University of Goettingen. Four patients were lost during follow-up. Data were gained from 88 male and 12 female patients; mean age was 65.5 ± 9 years. A total of 396 vessels were bypassed (4 ± 0.9 vessels per patient. In 98% left internal thoracic artery (LITA was used as arterial bypass graft and a total of 114 vessels were endarterectomized. CE was performed on right coronary artery (RCA (n = 55, on left anterior descending artery (LAD (n = 52 and circumflex artery (RCX (n = 7. Ninety-five patients suffered from 3-vessel-disease, 3 from 2-vessel- and 2 from 1-vessel-disease. Closed technique was used in 18%, open technique in 79% and in 3% a combination of both. The most frequent endarterectomized localization was right coronary artery (RCA = 55%. Despite the severity of endstage atherosclerosis, hospital mortality was only 5% (n = 5. During follow-up (24.5 ± 13.4 months, which is 96% complete (4 patients were lost caused by unknown address 8 patients died (cardiac

  7. Comparison of Duke ergo-metric score and of the classification based on scintigraphic data in the stratification of coronaries

    International Nuclear Information System (INIS)

    Ouhayoun, E.; Coca, F.J.; Payoux, P.; Tafani, J.A.M.; Esquerre, J.P.

    1997-01-01

    Stratification of risk (sudden death and infarction) remains a major problem of the way the coronaries are cared. Since 1987, a score based on the test-to-effort data was proposed by Mark and coll. of 'Duke University' team. They tried to demonstrate that this score provides a reliable classification of patients. We have compared the results obtained by using this score with those issued from the simultaneous analysis of the left ventricle (LV) function and LV perfusion. A hundred patients afflicted with coronaries (stenoses > 50%) benefited by a coupled study of the LV function and perfusion at rest and under effort made by means of MIBI scintigraphy. The effort test allowed calculating the 'Duke' score by means of a formula in terms of the angor index defined as follows: 0 for absence, 1 for angor and 2 for angor motivating cessation. According to Duke score three classes can be defined: patients of low risk, score ≥ 5; patients of intermediate risk, score in between 5 and -10; patients of high risk, score ≤ -10. Ejection fraction at effort acme was measured in every patient as well as the extension of perfusion defect, evaluated semi-quantitatively at effort and rest on the basis of bull's eye. Three groups of patients were created according to the results of perfusion+function couple): (A)- normal perfusion and function, the case of good prognostication; (B)- patients slightly afflicted (FEV effort > 50% and in-effort defect extension effort 50%). The last criteria were proved by several studies as bad prognostication. A table presents the risks according the Duke score for the three classes. One can observe that one third of the patients severely afflicted by confirmed ischemia are classified in the low-risk class. Besides, the majority of patients are ranked with intermediary risk, independently of scintigraphic results. In conclusion, these results concerning the stratification of coronaries show the superiority of the criteria based on scintigraphy over

  8. Feasibility and diagnostic accuracy of a low radiation exposure protocol for prospective ECG-triggering coronary MDCT angiography

    International Nuclear Information System (INIS)

    Pontone, G.; Andreini, D.; Bartorelli, A.L.; Bertella, E.; Mushtaq, S.; Foti, C.; Formenti, A.; Chiappa, L.; Annoni, A.; Cortinovis, S.; Baggiano, A.; Conte, E.; Bovis, F.; Veglia, F.; Ballerini, G.; Agostoni, P.; Fiorentini, C.; Pepi, M.

    2012-01-01

    Aim: To compare the feasibility, accuracy, and effective radiation dose (ED) of multidetector computed tomography (MDCT) in the detection of coronary artery disease using a combined ED-saving strategy including prospective electrocardiogram (ECG) triggering with a short x-ray window and a body mass index (BMI)-adapted imaging protocol using adaptive statistical iterative reconstruction (ASIR; group 1), in comparison with a prospective ECG triggering strategy alone (group 2). Materials and methods: One hundred and seventy patients scheduled for invasive coronary angiography (ICA) were evaluated. Fourteen patients were not eligible for MDCT. The remaining 156 patients were randomized to group 1 (78 patients) and group 2 (78 patients). Eight and 11 patients in groups 1 and 2, respectively, were excluded after randomization because the patients’ heart rates were >65 beats/min. MDCT images were assessed for feasibility, signal-to-noise ration (SNR), and contrast-to-noise ratio (CNR), accuracy in detection of coronary stenoses >50% versus ICA and for ED. Results: The feasibility, SNR, CNR, accuracy in a segment-based and patient-based model were similar in both groups (97 versus 95%, 14.5 ± 3.9 versus 14.2 ± 4.1, 16 ± 4.6 versus 16.5 ± 4.4, 95 versus 94% and 97 versus 99%, respectively). The ED in group 1 was 72% lower than in group 2 (2.1 ± 1.2 versus 7.5 ± 1.8 mSv, respectively; p < 0.01). Conclusions: The use of a multi-parametric ED saving protocol results in a significant reduction in ED without a negative impact on accuracy.

  9. Feasibility and diagnostic accuracy of a low radiation exposure protocol for prospective ECG-triggering coronary MDCT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Pontone, G., E-mail: gianluca.pontone@ccfm.it [Centro Cardiologico Monzino, IRCCS, Milan (Italy); Andreini, D. [Centro Cardiologico Monzino, IRCCS, Milan (Italy); Bartorelli, A.L. [Centro Cardiologico Monzino, IRCCS, Milan (Italy); Department of Cardiovascular Sciences, University of Milan, Milan (Italy); Bertella, E.; Mushtaq, S.; Foti, C.; Formenti, A.; Chiappa, L.; Annoni, A.; Cortinovis, S.; Baggiano, A.; Conte, E.; Bovis, F.; Veglia, F.; Ballerini, G. [Centro Cardiologico Monzino, IRCCS, Milan (Italy); Agostoni, P.; Fiorentini, C. [Centro Cardiologico Monzino, IRCCS, Milan (Italy); Department of Cardiovascular Sciences, University of Milan, Milan (Italy); Pepi, M. [Centro Cardiologico Monzino, IRCCS, Milan (Italy)

    2012-03-15

    Aim: To compare the feasibility, accuracy, and effective radiation dose (ED) of multidetector computed tomography (MDCT) in the detection of coronary artery disease using a combined ED-saving strategy including prospective electrocardiogram (ECG) triggering with a short x-ray window and a body mass index (BMI)-adapted imaging protocol using adaptive statistical iterative reconstruction (ASIR; group 1), in comparison with a prospective ECG triggering strategy alone (group 2). Materials and methods: One hundred and seventy patients scheduled for invasive coronary angiography (ICA) were evaluated. Fourteen patients were not eligible for MDCT. The remaining 156 patients were randomized to group 1 (78 patients) and group 2 (78 patients). Eight and 11 patients in groups 1 and 2, respectively, were excluded after randomization because the patients' heart rates were >65 beats/min. MDCT images were assessed for feasibility, signal-to-noise ration (SNR), and contrast-to-noise ratio (CNR), accuracy in detection of coronary stenoses >50% versus ICA and for ED. Results: The feasibility, SNR, CNR, accuracy in a segment-based and patient-based model were similar in both groups (97 versus 95%, 14.5 {+-} 3.9 versus 14.2 {+-} 4.1, 16 {+-} 4.6 versus 16.5 {+-} 4.4, 95 versus 94% and 97 versus 99%, respectively). The ED in group 1 was 72% lower than in group 2 (2.1 {+-} 1.2 versus 7.5 {+-} 1.8 mSv, respectively; p < 0.01). Conclusions: The use of a multi-parametric ED saving protocol results in a significant reduction in ED without a negative impact on accuracy.

  10. Coronary ostium occlusion by coronary cusp displacement in Williams syndrome.

    Science.gov (United States)

    Shiohama, Tadashi; Fujii, Katsunori; Ebata, Ryota; Funabashi, Nobusada; Matsumiya, Goro; Saito, Yuko Kazato; Takechi, Fumie; Yonemori, Yoko; Nakatani, Yukio; Shimojo, Naoki

    2016-06-01

    Williams syndrome is a contiguous gene deletion syndrome resulting from a heterozygous deletion on chromosome 7q11.23, and is characterized by distinctive facial features and supravalvular aortic stenosis (SVAS). This syndrome rarely presents unpredictable cardiac death, and yet, as illustrated in the present case, it is still not possible to predict it, even on close monitoring. We herein describe the case of a 6-year-old Japanese girl with Williams syndrome, who had sudden cardiac collapse due to cardiac infarction after pharyngitis. Cardiac failure followed a critical course that did not respond to catecholamine support or heart rest with extracardiac mechanical support. Although marked coronary stenosis was not present, the left coronary cusp abnormally adhered to the aortic wall, which may synergistically cause coronary ostium occlusion with SVAS. Altered hemodynamic state, even that caused by the common cold, may lead to critical myocardial events in Williams syndrome with SVAS. © 2015 Japan Pediatric Society.

  11. NEUROTICISM PROFILE IN CORONARY HEART DISEASE

    OpenAIRE

    Bhargava, S. C.; Sharma, S. N.; Agarwal, B. V.

    1980-01-01

    SUMMARY Thirty seven cases of coronary heart disease and 30 normal healthy controls were administered Hindi version of MHQ. The coronary heart disease patients scored significantly higher on total neuroticism, free-floating anxiety and somatic anxiety subscales of MHQ.

  12. Coronary artery with aberrant origin malignant right

    International Nuclear Information System (INIS)

    Ozcan, E.; Bozlar, U.; Demirkol, S.; Saglam, M.

    2012-01-01

    Full text: Introduction: Congenital anomalies of the coronary arteries is a major cause of sudden death, especially in young patients. Objectives and tasks: In this study we aim to present a young patient with chest pain who had malignant right coronary artery (RCA) with aberrant origin. Materials and methods: 24-year-old man who applied cardiology clinic for chest pain and palpitations especially after exercise, was referred to our clinic for coronary computed tomography (CT) angiography to evaluate coronary artery anomalies. Results: In CT angiography; we detected aberrant RCA with origin of tubularly part of ascendant aorta with a malignant course between aorta and pulmonary artery. Left main coronary artery, left anterior descending and circumflex artery had normal origin and course. Conclusion: Coronary artery with malignant course may cause sudden death especially after exercise. Coronary CT angiography has an important role in diagnosis of congenital coronary artery anomalies, with high resolution multiplanner reformatted images

  13. Coronary spasm induced by dipyridamole

    International Nuclear Information System (INIS)

    Wartski, M.; Caussin, C.; Lancelin, B.

    2001-01-01

    A 59 years old man was admitted at hospital for recurrent instable angina 1 month after coronary artery bypass surgery. Coronary artery disease started with a transmural antero-septo-apical myocardial infarction without thrombolysis and a percutaneous angioplasty with endo-prothesis on proximal left anterior descendant artery (LAD) is performed Because of recurrent rest angina and subacute stent thrombosis, a coronary artery bypass surgery (CABG) is performed with anastomosis of the left internal thoracic artery on LAD. The patient is admitted for recurrent rest angina one month after CABG. On ECG performed during chest pain, a ST-T segment elevation occurred on inferior leads. Coronary angiography showed no significant stenosis on endo-prothesis and no bypass graft dysfunction. Dipyridamole scintigraphy was realized. 2 minutes after the beginning of Dipyridamole infusion, a ST-T elevation occurred on inferior leads and two marked antero-septal and inferior defects were noticed on myocardial scintigraphy. Images at rest showed a clear improvement in the anterior wall and the inferior wall became normally perfused Patient was treated with anti-spastic drugs and a new coronarography with methyl-ergotamine test was performed inducing chest pain, ST-T elevation on inferior leads and tri-truncular coronary spasm. Patient's treatment was then modified with introduction of Nifedipine. The patient did not experienced new recurrent chest pain and remained totally asymptomatic few months later. (authors)

  14. Endovascular gamma-irradiation for prevention of restenosis after angioplasty of femoropopliteal de-novo-stenoses. Long-term results of a feasibility study

    International Nuclear Information System (INIS)

    Krueger, K.; Zaehringer, M.; Schulte, O.; Lackner, K.; Bendel, M.; Bongartz, R.; Nolte, M.

    2002-01-01

    Objectives: To evaluate the performance and efficacy of endovascular irradiation after percutaneous transluminal angioplasty (PTA) of de-novo femoropopliteal stenoses in a pilot study. Methods: 6 patients received non-centered endovascular irradiation (12 Gray at surface of the vessel wall) immediately after angioplasty of de-novo femoropopliteal stenosis, 1 patient was given centered endovascular irradiation using 192-iridium (12 Gray at surface of the vessel wall) Centered irradiation was considered for two other patients. Duplex sonographies and interviews were performed the day before and after PTA and after 1, 3, 6, 9, 12, 18, 24 months up to 4 years. Intraarterial angiography was performed in symptomatic patients. Results: Non-centered endovascular irradiation was possible in all patiens without problems or complications. Centered irradiation was not possible in two patients with the cross-over approach. One thromboembolic complication occurred during centered irradiation. Both restenosis and new stenosis at the edge of irradiated distance occurred in 1/7 patiens. No other side effects were observed during follow-up. Conclusions: In our pilot study endovascular irradiation after angioplasty of de-novo femoropopliteal stenosis was possible with low rates of complications and restenosis and taking vessel anatomy into account. (orig.) [de

  15. Acidosis activates complement system in vitro.

    OpenAIRE

    Emeis, M; Sonntag, J; Willam, C; Strauss, E; Walka, M M; Obladen, M

    1998-01-01

    We investigated the in vitro effect of different forms of acidosis (pH 7.0) on the formation of anaphylatoxins C3a and C5a. Metabolic acidosis due to addition of hydrochloric acid (10 micromol/ml blood) or lactic acid (5.5 micromol/ml) to heparin blood (N=12) caused significant activation of C3a and C5a compared to control (both p=0.002). Respiratory acidosis activated C3a (p=0.007) and C5a (p=0.003) compared to normocapnic controls. Making blood samples with lactic acidosis hypocapnic result...

  16. In vitro meat: Zombies on the menu?

    OpenAIRE

    Stephens, NS

    2010-01-01

    In April 2008 the In Vitro Meat Consortium held its first meeting at the Norwegian Food Research Institute. They are a group of scientists and advocates who seek to turn the techniques of tissue engineering to the production of food, producing meat in laboratories that has at no point been part of a living animal. This is a fascinating technology, and one that fits well with the topic of this SCRIPTed analysis section: the ‘zombification’ of meat products. I have been conducting interviews wi...

  17. In vitro organogenesis in some citrus species

    Directory of Open Access Journals (Sweden)

    Evandro Henrique Schinor

    2011-06-01

    Full Text Available In vitro organogenesis of Citrus was studied for the genotypes Citrus sinensis cv. 'Natal', C. limonia, C. volkameriana, and C. aurantium, with the use of epicotyl segments-derived explants, cultured in MT salts and vitamins medium supplemented with different concentrations of 6-benzylaminopurine (BAP - 0.0; 0.5; 1.0; 1.5 or 2.0 mg L-1. For the recalcitrant genotypes C. limonia and C. aurantium the in vitro organogenesis was also studied with internodal segments-derived explants, cultured in MT salts and vitamins medium supplemented with 0; 0.5; 1.0; 2.0, or 4.0 mg L-1 of BAP. The efficiency of culture medium supplementation with the combination of BAP (0.0; 1.0, or 2.0 mg L-1 and NAA (1-naphthaleneacetic acid - 0.0; 0.3, or 0.5 mg L-1 in the development of adventitious shoots was evaluated for C. aurantium. Culture medium supplementation with BAP is not essential for the adventitious shoots development in the four genotypes studied when epicotyl segments-derived explants are used. In general, culture media supplementation with BAP decreased the percentage of responsive explants excepted for C. sinensis cv. 'Natal' and C. limonia when the concentrations of 1.5 and 2.0 mg/L were used. The presence of cytokinin, in concentrations up to 2 mg/L, stimulated the in vitro organogenesis when internodal segments-derived explants were used for C. limonia and C. aurantium. For C. aurantium no adventitious shoots developed in explants (internodal segments cultured in basal culture medium, without BAP supplementation. Although no statistic differences could be detected, culture media supplementation with the combination of BAP and NAA favored the development of adventitious shoots in C. aurantium. The best concentration of NAA varied according to BAP concentration. The results presented herein, show that Citrus in vitro organogenesis depends on the interaction of culture medium composition, explant differentiation level, and genotype.

  18. Enhancement of in vitro Guayule propagation

    Science.gov (United States)

    Dastoor, M. N.; Schubert, W. W.; Petersen, G. R. (Inventor)

    1982-01-01

    A method for stimulating in vitro propagation of Guayule from a nutrient medium containing Guayule tissue by adding a substituted trialkyl amine bioinducing agent to the nutrient medium is described. Selective or differentiated propagation of shoots or callus is obtained by varying the amounts of substituted trialky amine present in the nutrient medium. The luxuriant growth provided may be processed for its poly isoprene content or may be transferred to a rooting medium for production of whole plants as identical clones of the original tissue. The method also provides for the production of large numbers of Guayule plants having identical desirable properties such as high polyisoprene levels.

  19. Characterization of in vitro translation products

    International Nuclear Information System (INIS)

    Jagus, R.

    1987-01-01

    This chapter describes the characterization of in vitro translation products by the most commonly used techniques. The methods include SDS-polyacrylamide gel electrophoresis (SDS-PAGE), combined with immunoprecipitation and/or fluorography of [ 35 S]methionine-labeled translation products. The other frequently used characterization tool, translation of hybrid-selected mRNA or hybrid-arrested translation, is treated separately in this volume. Methods are also given for the recognition of mRNAs coding for secreted or membrane proteins

  20. In vitro propagation of lnula royleana DC

    Directory of Open Access Journals (Sweden)

    Anna Stojakowska

    2011-01-01

    Full Text Available A micropropagation method, through axillary shoot proliferation, was elaborated for Inula royleana DC. (Asteraceae, a medicinal plant native of Himalaya. Primary explants (cotyledonary node explants and secondary explants (node explants of in vitro regenerated shoots of the plant, inoculated on MS medium supplemented with 0.1 μM NAA and 5.0 μM kinetin, regenerated 3.4 ± 1.2 and 5.1 ± 1.9 axillary shoots per explant, respectively. The regenerated shoots were easily rooting and adapting to growth in soil.

  1. In vitro and in vivo cell-capture strategies using cardiac stent technology - A review.

    Science.gov (United States)

    Ravindranath, Rohan R; Romaschin, Alexander; Thompson, Michael

    2016-01-01

    Stenosis is a symptom of coronary artery disease (CAD), and is caused by narrowing of arteries in the heart. Over the last several decades, medical implants such as cardiac stents have been developed to counter stenosis. Upon implantation of a stent to open up a restricted artery, narrowing of the artery can reoccur (restenosis), due to an immune response launched by the body towards the stent. Currently, restenosis is a major health concern for patients who have undergone heart surgery for coronary artery disease. Recently, there have been new methods developed to combat restenosis, which have shown potential signs of success. One proposed method is the use of stents to capture cells, thereby reducing immune response. This review will explore the different methods for cell capture both in vitro and in vivo. Biological modifications of the stent will be surveyed, as well as the use of surface science to immobilize biological probes. Immobilization of proteins and nucleotides, as well as use of magnetic field are all methods that will be further discussed. Finally, concluding remarks and future prospects will be presented. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  2. Detection of coronary calcification in ultrafast CT compared to coronary angiography

    International Nuclear Information System (INIS)

    Koesling, S.; Hoffmann, U.; Rother, T.; Lieberenz, S.; Heywang-Koebrunner, S.H.; Schulz, H.G.

    1994-01-01

    The angiographical findings of 24 patients with coronary artery disease were compared with qualitative and quantitative detection of coronary calcification by ultrafast CT. Doubts concerning the capabilities of the ultrafast CT for a screening of coronary artery disease arise when the results of one third false positive and fase negative findings are considered. Variations in the quantification of coronary calcification were too great to allow a realistic assessment of the degree of stenosis of the coronary arteries. (orig.) [de

  3. HUMAN CORONARY ARTERIES- A STUDY BASED ON GROSS ANATOMY AND CORONARY CAST

    Directory of Open Access Journals (Sweden)

    Vijayamma K. N

    2018-01-01

    Full Text Available BACKGROUND Present study is an attempt to throw light upon the coronary arterial pattern, variations in arterial distribution and extent of intercoronary anastomosis and arterial preponderance in different age groups. MATERIALS AND METHODS Total of 115 hearts were made use for this study. Ninety hearts were dissected for the gross anatomical study of coronary arteries and 25 hearts including three fetal hearts were used for the coronary cast study. The right and left coronary arteries were traced from aortic sinus along the atrioventricular groove to the area of its termination. The atrial ventricular and septal branches were traced and looked for anastomosis. Coronary casts were prepared by injecting coloured liquid latex through the coronary ostia and the branching pattern and anastomosis were studied. The coronary arterial pattern, extent of distribution of its branches, arterial preponderance and variations were observed. RESULTS It was found that 73 % cases of SA nodal branch arise from right coronary artery and 27 % from circumflex branch of left coronary artery. SA node has dual blood supply from both coronary arteries in 4% cases. Right coronary preponderance was observed in 83% of cases and left coronary preponderance in 11 % cases, and balanced supply in 6% cases. Coronary cast was helpful to understand the branching pattern of vessels, and the anastomosis of small capillaries. It was also seen that all 11 % of left preponderance were seen in male hearts and all of the 31 female hearts dissected were right preponderant. CONCLUSION Coronary arteries are called end arteries functionally. Right coronary artery originates from anterior aortic sinus in all cases except one which takes origin from posterior left aortic sinus along with left coronary artery. Right coronary preponderance is observed in 83% cases. Left coronary artery branching pattern shows variability. Left coronary preponderance was observed in 11% and all cases are male

  4. Nitric oxide fails to confer endogenous antiarrhythmic cardioprotection in the primate heart in vitro.

    Science.gov (United States)

    Pabla, R; Curtis, M J

    2007-04-01

    The role of nitric oxide (NO) in cardiac pathophysiology remains controversial. According to data from several studies using rat and rabbit isolated hearts, NO is an endogenous cardioprotectant against reperfusion-induced ventricular fibrillation (VF). Thus, if cardiac NO production is abolished by perfusion with L-N(G)-nitro-L-arginine methylester (L-NAME) (100 microM) there is a concomittant increase in the incidence of reperfusion-induced VF, with L-NAME's effects on NO and VF prevented by L- (but not D-) arginine co-perfusion. To make a better estimate of the clinical relevance of these findings, 100 microM L-NAME was tested in primate hearts under similar conditions. Marmoset (Callithrix jaccus) hearts, isolated and perfused, were subjected to 60 min left regional ischaemia followed by 10 min reperfusion in vitro. The ECG was recorded and NO in coronary effluent measured by chemiluminescence. L-NAME (100 micro M) decreased NO in coronary effluent throughout ischaemia and reperfusion (e.g. from 3720+/-777 pmol min(-1) g(-1) in controls to 699+/-98 pmol min(-1) g(-1) after 5 min of ischaemia) and, during ischaemia, lowered coronary flow and reduced heart rate, actions identical to those seen in rat and rabbit hearts. However, the incidence of reperfusion-induced VF was unchanged (20%, with or without L-NAME). A species difference exists in the effectiveness of endogenous NO to protect hearts against reperfusion-induced VF. The present primate data, which presumably take precedence over rat and rabbit data, cast doubt on the clinical relevance of NO as an endogenous, antiarrhythmic, cardioprotectant.

  5. Nuclear techniques and in vitro culture for plant improvement

    International Nuclear Information System (INIS)

    1986-01-01

    The continuous series of food shortages in many parts of the world have led scientists to consider the possibilities of using the new techniques to develop better varieties of plants. The basis for plant breeding is suitable genetic variability and mutation induction as the means to create additional variation. In vitro techniques are a relatively new tool in practical plant breeding. These Proceedings contain 62 papers and posters presented at the symposium, as well as excerpts from the discussions. The Symposium presentations are divided into the following sessions: Genetic variation from in vitro culture; Genetic stability of in vitro cultures; In vitro culture with application of mutagens; Haploids; In vitro mutant selection; Use of genetic variation derived by in vitro culture; In vitro techniques as aids in mutation breeding and Genetic engineering. A separate abstract is prepared for each of these papers and posters

  6. Progress in genetics of coronary artery disease

    African Journals Online (AJOL)

    Radwa Gamal

    To the Editor. Coronary Heart Disease (CHD) is the leading cause of mortality and morbidity worldwide [1] and it is a result of coronary artery disease (CAD). Coronary artery disease refers to the build-up of atherosclerotic plaque in the blood vessels that supply oxygen and nutrients to the heart. Progressive infiltration of the ...

  7. Coronary CT in Acute Cardiac Care

    NARCIS (Netherlands)

    A. Dedic (Admir)

    2016-01-01

    markdownabstractCoronary CT angiography is a well-established diagnostic modality for stable angina pectoris. It provides an angiographic, non-invasive alternative for the diagnosis of coronary artery disease, exceeding in the ability to exclude important coronary artery disease. Having the ability

  8. Feasibility of recanalization of human coronary arteries using high-intensity ultrasound.

    Science.gov (United States)

    Ernst, A; Schenk, E A; Woodlock, T J; Alliger, H; Gottlieb, S; Child, S Z; Meltzer, R S

    1994-01-15

    To investigate the feasibility of ultrasonic recanalization of obstructed human coronary arteries in vitro, high-intensity ultrasound was applied to 16 coronary arteries obtained at autopsy, using a prototype instrument enabling insonification through a catheter tip. It was a 119 cm long, 0.95 mm thick wire in an 8Fr catheter connected to an external ultrasonic transformer and power generator. A 5 MHz phased-array 2-dimensional echocardiography instrument was used to determine minimal luminal diameter and percent diameter narrowing before and after ultrasound application. The ultrasonic energy was delivered at 21.5 kHz and with a 52 +/- 19 micrometer average amplitude of tip displacement. The mean percent luminal diameter narrowing, flow rate and mean pressure gradient before ultrasound exposure were 74 +/- 11%, 97 +/- 61 ml/min, and 92 +/- 18 mm Hg, respectively. After recanalization, the mean percent luminal diameter narrowing decreased to 45 +/- 17% (p ultrasound application. Mechanical fracture of the wire occurred in 8 cases (50%). No signs of thermal injury were found on histology. Thus, ultrasonic recanalization of human coronary arteries in vitro is feasible. It may reduce obstruction and improve blood flow. Debris sizes are sufficiently small to minimize the hazard of peripheral embolization.

  9. Stereoselective inhibition of thromboxane-induced coronary vasoconstriction by 1,4-dihydropyridine calcium channel antagonists

    International Nuclear Information System (INIS)

    Eltze, M.; Boer, R.; Sanders, K.H.; Boss, H.; Ulrich, W.R.; Flockerzi, D.

    1990-01-01

    The biological activity of the (+)-S- and (-)-R-enantiomers of niguldipine, of the (-)-S- and (+)-R-enantiomers of felodipine and nitrendipine, and of rac-nisoldipine and rac-nimodipine was investigated in vitro and in vivo. Inhibition of coronary vasoconstriction due to the thromboxane A2 (TxA2)-mimetic U-46619 in guinea pig Langendorff hearts, displacement of (+)-[ 3 H]isradipine from calcium channel binding sites of guinea pig skeletal muscle T-tubule membranes, and blood pressure reduction in spontaneously hypertensive rats were determined. The enantiomers were obtained by stereoselective synthesis. Cross-contamination was less than 0.5% for both S- and R-enantiomers of niguldipine and nitrendipine and less than 1% for those of felodipine. From the doses necessary for a 50% inhibition of coronary vasoconstriction, stereoselectivity ratios for (+)-(S)-/(-)-(R)-niguldipine, (-)-(S)-/(+)-(R)-felodipine, and (-)-(S)-/(+)-(R)-nitrendipine of 28, 13, and 7, respectively, were calculated. The potency ratio rac-nisoldipine/rac-nimodipine was 3.5. Ratios obtained from binding experiments and antihypertensive activity were (+)-(S)-/(-)-(R)-niguldipine = 45 and 35, (-)-(S)-/(+)-(R)-felodipine = 12 and 13, (-)-(S)-/(+)-(R)-nitrendipine = 8 and 8, and rac-nisoldipine/rac-nimodipine = 8 and 7, respectively. Highly significant correlations were found between the in vitro potency of the substances to prevent U-46619-induced coronary vasoconstriction and their affinity for calcium channel binding sites as well as their antihypertensive activity

  10. In Vitro Antimicrobial Susceptibility Patterns of Blastocystis.

    Science.gov (United States)

    Roberts, Tamalee; Bush, Stephen; Ellis, John; Harkness, John; Stark, Damien

    2015-08-01

    Blastocystis is the most common human enteric protist with controversial clinical significance. Metronidazole is considered a first-line treatment for Blastocystis infection; however, there has been increasing evidence for the lack of efficacy of this treatment. Treatment failure has been reported in several clinical cases, and recent in vitro studies have suggested the occurrence of metronidazole-resistant strains. In this study, we tested 12 Blastocystis isolates from 4 common Blastocystis subtypes (ST1, ST3, ST4, and ST8) against 12 commonly used antimicrobials (metronidazole, paromomycin, ornidazole, albendazole, ivermectin, trimethoprim-sulfamethoxazole [TMP-SMX], furazolidone, nitazoxanide, secnidazole, fluconazole, nystatin, and itraconazole) at 10 different concentrations in vitro. It was found that each subtype showed little sensitivity to the commonly used metronidazole, paromomycin, and triple therapy (furazolidone, nitazoxanide, and secnidazole). This study highlights the efficacy of other potential drug treatments, including trimethoprim-sulfamethoxazole and ivermectin, and suggests that current treatment regimens be revised. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  11. Assessing nanotoxicity in cells in vitro.

    Science.gov (United States)

    Hillegass, Jedd M; Shukla, Arti; Lathrop, Sherrill A; MacPherson, Maximilian B; Fukagawa, Naomi K; Mossman, Brooke T

    2010-01-01

    Nanomaterials are commonly defined as particles or fibers of less than 1 microm in diameter. For these reasons, they may be respirable in humans and have the potential, based upon their geometry, composition, size, and transport or durability in the body, to cause adverse effects on human health, especially if they are inhaled at high concentrations. Rodent inhalation models to predict the toxicity and pathogenicity of nanomaterials are prohibitive in terms of time and expense. For these reasons, a panel of in vitro assays is described below. These include cell culture assays for cytotoxicity (altered metabolism, decreased growth, lytic or apoptotic cell death), proliferation, genotoxicity, and altered gene expression. The choice of cell type for these assays may be dictated by the procedure or endpoint selected. Most of these assays have been standardized in our laboratory using pathogenic minerals (asbestos and silica) and non-pathogenic particles (fine titanium dioxide or glass beads) as negative controls. The results of these in vitro assays should predict whether testing of selected nanomaterials should be pursued in animal inhalation models that simulate physiologic exposure to inhaled nanomaterials. Conversely, intrathoracic or intrapleural injection of nanomaterials into rodents can be misleading because they bypass normal clearance mechanisms, and non-pathogenic fibers and particles can test positively in these assays.

  12. In Vitro Analysis of Metabolite Transport Proteins.

    Science.gov (United States)

    Roell, Marc-Sven; Kuhnert, Franziska; Zamani-Nour, Shirin; Weber, Andreas P M

    2017-01-01

    The photorespiratory cycle is distributed over four cellular compartments, the chloroplast, peroxisomes, cytoplasm, and mitochondria. Shuttling of photorespiratory intermediates between these compartments is essential to maintain the function of photorespiration. Specific transport proteins mediate the transport across biological membranes and represent important components of the cellular metabolism. Although significant progress was made in the last years on identifying and characterizing new transport proteins, the overall picture of intracellular metabolite transporters is still rather incomplete. The photorespiratory cycle requires at least 25 transmembrane transport steps; however to date only plastidic glycolate/glycerate transporter and the accessory 2-oxoglutarate/malate and glutamate/malate transporters as well as the mitochondrial transporter BOU1 have been identified. The characterization of transport proteins and defining their substrates and kinetics are still major challenges.Here we present a detailed set of protocols for the in vitro characterization of transport proteins. We provide protocols for the isolation of recombinant transport protein expressed in E. coli or Saccharomyces cerevisiae and the extraction of total leaf membrane protein for in vitro analysis of transporter proteins. Further we explain the process of reconstituting transport proteins in artificial lipid vesicles and elucidate the details of transport assays.

  13. In vitro disposition profiling of heterocyclic compounds.

    Science.gov (United States)

    Keemink, Janneke; Wuyts, Benjamin; Nicolaï, Johan; Jonghe, Steven De; Stella, Alessandro; Herdewijn, Piet; Augustijns, Patrick; Annaert, Pieter

    2015-08-01

    Compound libraries that are screened for biological activity commonly contain heterocycles. Besides potency, drug-like properties need to be evaluated to ensure in vivo efficacy of test compounds. In this context, we determined hepatic and intestinal disposition profiles for 17 heterocyclic compounds. All studied compounds showed rapid uptake in suspended rat hepatocytes, whereas metabolism was poor and the rate-limiting step in hepatic elimination. In vitro assays demonstrated a relatively low solubility and high intestinal permeability. Based on these in vitro data, heterocycles were categorized in the biopharmaceutics classification system (BCS) and the biopharmaceutics drug disposition classification system (BDDCS) to predict disposition characteristics before clinical data are available. Our findings emphasized the importance to use hepatocytes in addition to microsomes to study metabolism, since the latter lack non-microsomal enzymes and cellular context. Moreover, intracellular exposure should be considered to gain insight in the relevant fraction of the compound available at the enzymatic site. Finally, the study reveals discrepancies associated with the classification of heterocycles in BCS versus BDDCS. These probably originate from the binary character of both systems. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. The in vitro toxicology of Swedish snus

    Science.gov (United States)

    Coggins, Christopher R. E.; Ballantyne, Mark; Curvall, Margareta; Rutqvist, Lars-Erik

    2012-01-01

    Three commercial brands of Swedish snus (SWS), an experimental SWS, and the 2S3 reference moist snuff were each tested in four in vitro toxicology assays. These assays were: Salmonella reverse mutation, mouse lymphoma, in vitro micronucleus, and cytotoxicity. Water extractions of each of the 5 products were tested using several different concentrations; the experimental SWS was also extracted using dimethyl sulfoxide (DMSO). Extraction procedures were verified by nicotine determinations. Results for SWS in the mutagenicity assays were broadly negative: there were occasional positive responses, but these were effectively at the highest concentration only (concentrations well above those suggested by regulatory guidelines), and were often associated with cytotoxicity. The 2S3 reference was unequivocally positive in one of the three conditions of the micronucleus assay (MNA), at the highest concentration only. Positive controls produced the expected responses in each assay. The SWS data are contrasted with data reported for combusted tobacco in the form of cigarettes, where strongly positive responses have been routinely reported for mutagenicity and cytotoxicity. These negative findings in a laboratory setting concur with the large amount of epidemiological data from Sweden, data showing that SWS are associated with considerably lower carcinogenic potential when compared with cigarettes. PMID:22400986

  15. Retinol improves bovine embryonic development in vitro

    Directory of Open Access Journals (Sweden)

    Edwards J Lannett

    2004-12-01

    Full Text Available Abstract Retinoids are recognized as important regulators of vertebrate development, cell differentiation, and tissue function. Previous studies, performed both in vivo and in vitro, indicate that retinoids influence several reproductive events, including follicular development, oocyte maturation and early embryonic development. The present study evaluated in vitro effects of retinol addition to media containing maturing bovine oocytes and developing embryos in both a low oxygen atmosphere (7% and under atmospheric oxygen conditions (20%. In the first experiment, abbatoir collected bovine oocytes were matured in the presence or absence of varying concentrations of retinol. After a 22–24 hour maturation period the oocytes were fertilized, denuded 18 hours later and cultured in a modified synthetic oviductal fluid (mSOF in a humidified atmosphere at 38.5 degrees C, 5% CO2, 7% O2 and 88% N2. Cleavage rates did not differ among control and retinol-treated oocytes in all three experiments. Addition of 5 micromolar retinol to the maturation medium (IVM tended (p

  16. Solubility of plutonium dioxide aerosols, in vitro

    International Nuclear Information System (INIS)

    Newton, G.J.; Kanapilly, G.M.

    1976-01-01

    Solubility of plutonium aerosols is an important parameter in establishing risk estimates for industrial workers who might accidentally inhale these materials and in evaluating environmental health impacts associated with Pu. In vitro solubility of industrial plutonium aerosols in a simulated lung fluid is compared to similar studies with ultrafine aerosols from laser ignition of delta phase plutonium metal and laboratory-produced spherical particles of 238 PuO 2 and 239 PuO 2 . Although relatively insoluble, industrial plutonium-mixed oxide aerosols were much more soluble than laboratory-produced plutonium dioxide particles. Chain agglomerate aerosols from laser ignition of metallic Pu indicated in vitro dissolution half-times of 10 and 50 days for activity median aerodynamic diameter (AMAD) of 0.7 and 2.3 μm, respectively. Plutonium-containing mixed oxide aerosols indicated dissolution half-times of 40 to 500 days for particles formed by industrial powder comminution and blending. Centerless grinding of fuel pellets yielded plutonium-containing aerosols with dissolution half-times of 1200 to 8000 days. All mixed oxide particles were in the size range 1.0 μm to 2.5 μm AMAD

  17. Coronary Artery Bypass in Octogenarians

    Directory of Open Access Journals (Sweden)

    Chen-Yen Chien

    2012-09-01

    Full Text Available Prevalence of coronary artery disease (CAD has increased with the expansion of life span among the elderly population in the world. Hence, the issue of the coronary artery bypass in octogenarians has attracted more attention. Recent literature about the topic revealed nearly the same excellent results as those in the younger population under the newly developed operative techniques and improving concept in perioperative management and postoperative care. In this article, we review the current status of the procedure that was thought to be dangerous in the earlier era, including its risk factors, result, and benefit.

  18. Homocysteine and coronary heart disease

    DEFF Research Database (Denmark)

    Clarke, Robert; Bennett, Derrick A; Parish, Sarah

    2012-01-01

    Moderately elevated blood levels of homocysteine are weakly correlated with coronary heart disease (CHD) risk, but causality remains uncertain. When folate levels are low, the TT genotype of the common C677T polymorphism (rs1801133) of the methylene tetrahydrofolate reductase gene (MTHFR) appreci......Moderately elevated blood levels of homocysteine are weakly correlated with coronary heart disease (CHD) risk, but causality remains uncertain. When folate levels are low, the TT genotype of the common C677T polymorphism (rs1801133) of the methylene tetrahydrofolate reductase gene (MTHFR...

  19. Various clinical scenarios leading to development of the string sign of the internal thoracic artery after coronary bypass surgery: the role of competitive flow, a case series

    Directory of Open Access Journals (Sweden)

    Kolozsvari Rudolf

    2012-01-01

    Full Text Available Abstract Background The left internal mammary artery (LIMA is the choice for grafting of the left anterior descending coronary artery (LAD. One possible mechanism of the rare graft failure involve the presence of competitive flow. Method 105 patients who had undergone coronary bypass grafting between 1998 and 2000 were included in this observational study. The recatheterizations were performed 28 months after the operations. The rate of patency the LIMA grafts was determined, and the cases with graft failure were analyzed. Results The LIMA graft was patent in 99 patients (94%. Six patients (6% exhibited diffuse involution of the graft (string sign. The string sign was always associated with competitive flow as the basis of the LIMA graft involution. In one case quantitative re-evaluation of the preoperative coronary angiography revealed merely less than 50% diameter stenosis on the LAD with a nonligated side-branch of the LIMA. At recatheterization in two patients the pressure wire measurements demonstrated only a non-significant decrease of the fractional flow reserve (0.83 and 0.89, despite the 53% and 57% diameter stenosis in the angiogram. Another patient displayeda significant regression of the LAD lesion between the pre- and postoperative coronary angiography (from 76% to 44% as the cause of the development of the competitive flow. In one instance, a radial artery graft on the LAD during a redo bypass operation resulted in competitive flow in the radial graft due to the greater diameter than that of the LIMA. In a further patient, competitive flow developed from a short sequential part of the LIMA graft between the nonsignificantly stenosed diagonal branch and the LAD, with involution of the main part of the graft to the diagonal branch. Conclusions The most common cause of the development of the string sign of a LIMA graft due to competitive flow is overassessment of the lesion of the LAD. Regression of a previous lesion or some other

  20. Technetium-99m tetrofosmin rest/stress myocardial SPET with a same-day 2-hour protocol: comparison with coronary angiography. A Spanish-Portuguese multicentre clinical trial

    International Nuclear Information System (INIS)

    Montz, R.; Perez-Castejon, M.J.; Jurado, J.A.; Martin-Comin, J.; Esplugues, E.; Salgado, L.; Ventosa, A.; Cantinho, G.; Sa, E.P.; Fonseca, A.T.; Vieira, M.R.; Ortiz-Berrocal, J.; Magrina, J.; Ortega, D.; Puente, C.; Ferrer, A.I.; Pedrosa, J.; Latre, J.M.; Carreras, J.L.

    1996-01-01

    Technetium-99m tetrofosmin (Myoview) has unique properties for myocardial perfusion imaging very early after injection of the tracer. We used a very short same-day rest/stress protocol, to be performed within 2 h and evaluated its diagnostic accuracy. The study included 144 patients from seven Spanish and four Portuguese centres with a diagnosis of uncomplicated coronary artery disease (CAD); 78 patients (54%) had no history of prior myocardial infarction. Patients were injected with ≤300 MBq 99m Tc-tetrofosmin at rest and ≤900 MBq approximately 1 h later at peak exercise. Single-photon emission tomographic (SPET) acquisitions were initiated within 5-30 min post injection. The results were compared with those of coronary angiography (CA). The data of 142 patients were completely evaluable (two with non-evaluable images were excluded). The quality of rest images was excellent or good in 86%, regionally problematic in 7%, poor but well interpretable in 5% and non-evaluable in 2%. The overall sensitivity for the detection of CAD was 93%, the specificity 38% and the accuracy 85%. The localization of defects by SPET in relation the perfusion territories of stenosed vessels (≥=50%) was achieved with a sensitivity of 64% for the left anterior descending artery, 49% for the left circumflex artery and 86% for the right coronary artery, and an accuracy of 71%, 72% and 73% respectively. Concordance of SPET and CA was 62% for single-vessel disease and 68% for multivessel disease. In conclusion, this Spanish-Portuguese multicentre clinical trial confirmed, in a considerable number of patients who underwent coronary angiography, the feasibility of 99m Tc terofosmin (Myoview) rest/stress myocardial SPET using a very short protocol (2 h). (orig.)

  1. Preliminary study of 3.0 T contrast-enhanced whole heart coronary MR angiography using 32-channel coils with high acceleration factor

    International Nuclear Information System (INIS)

    Yang Qi; Li Kuncheng; Du Xiangying; Ma Heng; An Jing; Li Han; Xu Dong; Bi Xiaoming; Li Debiao

    2010-01-01

    Objective: To evaluate the diagnostic accuracy of 3.0 T contrast enhanced (CE) whole-heart coronary MRA (CE MRA) using 32-channel coils with high acceleration factor. Methods: Sixty patients with suspected coronary artery disease who were scheduled for coronary angiography (CAG) underwent CE CMRA at 3.0 T MRI scanner. A 32-channel receiver coil was used for data acquisition. For image acquisition, an ECG triggered,navigator-gated, inversion-recovery prepared, segmented gradient-echo sequence was used with an acceleration factor of three in the phase-encoding direction using GRAPPA reconstruction. Gd-BOPTA (0.15 mmol/kg body weight) was intravenously administered at a rate of 0.3 ml/s. The diagnostic accuracy in detecting significant stenoses (≥50% of vessel lumen) was evaluated using χ 2 test with X-ray angiography as the reference. Results: Whole-heart CE CMRA was successfully completed in 56 patients who were scheduled for CAG. The averaged imaging time was (6.0±1.3) min. 3.0 T CE CMRA using 32 channel coils correctly identified significant CAD in 28 patients and correctly ruled out CAD in 23 patients. The sensitivity and specificity were 93.3% and 88.5% respectively. Conclusion: Combined with dedicated 32-channel coils, 3.0 T CE CMRA allows significant reduction in imaging speed and reduced dose of the contrast agent. These improvements resulted in substantially improved overall accuracy of CE CMRA in detecting coronary artery disease. (authors)

  2. Eating meat with cesium and in vitro measurement; Fleisch mit Caesium essen und in vitro messen

    Energy Technology Data Exchange (ETDEWEB)

    Philipsborn, Henning von [Regensburg Univ. (Germany). Fakultaet Physik

    2017-08-01

    Wild pig meat contains in several regions still several thousand Bq per kg Cs-137, especially during spring. ICRP publication 56 specifies an effective half life of Cs-137 for man 50 to 150 days. In vivo measurements using whole-body counters are used for monitoring. In vitro measurements of excretion samples over several months are described in the contribution.

  3. A comparison of hybrid coronary revascularization and off-pump coronary revascularization.

    Science.gov (United States)

    Umakanthan, Ramanan; Leacche, Marzia; Gallion, Anna H; Byrne, John G

    2013-04-01

    Minimally invasive approaches to treat vascular disease have been accruing significant popularity over the last several decades. Due to progressive advances in technology, a variety of techniques are being now utilized in the field of cardiovascular surgery. The objectives of minimally invasive techniques are to curtail operative trauma and minimize perioperative morbidity without decreasing the quality of the treatment. The standard surgical approach for the treatment of coronary artery disease has traditionally been coronary artery bypass grafting surgery via median sternotomy. Off-pump coronary artery bypass grafting surgery offers a less invasive alternative and enables coronary revascularization to be performed without cardiopulmonary bypass. Hybrid coronary revascularization offers an even less invasive option in which minimally invasive direct coronary artery bypass can be combined with percutaneous coronary intervention. In this article, the authors review a recent publication comparing hybrid coronary revascularization and off-pump coronary artery bypass grafting surgery.

  4. Coronary Heart Disease and Exercises

    Directory of Open Access Journals (Sweden)

    Tolga SAKA

    2016-06-01

    Full Text Available Coronary heart disease is a chronic process, of which the progression can rapidly change the functional capacity of patients. In CAD patients, the quality of life can be improved with an appropriate exercise prescription. This article explains how a safe exercise program for CAD patients can be prescribed.

  5. Surgical manipulation of mammalian embryos in vitro.

    Science.gov (United States)

    Naruse, I; Keino, H; Taniguchi, M

    1997-04-01

    Whole-embryo culture systems are useful in the fields of not only embryology but also teratology, toxicology, pharmacology, and physiology. Of the many advantages of whole-embryo culture, we focus here on the surgical manipulation of mammalian embryos. Whole-embryo culture allows us to manipulate mammalian embryos, similarly to fish, amphibian and avian embryos. Many surgical experiments have been performed in mammalian embryos in vitro. Such surgical manipulation alters the destiny of morphogenesis of the embryos and can answer many questions concerning developmental issues. As an example of surgical manipulation using whole-embryo culture systems, one of our experiments is described. Microsurgical electrocauterization of the deep preaxial mesodermal programmed cell death zone (fpp) in the footplate prevented the manifestation of polydactyly in genetic polydactyly mouse embryos (Pdn/Pdn), in which fpp was abolished.

  6. In vitro hatching of Trichuris suis eggs

    DEFF Research Database (Denmark)

    Vejzagic, Nermina; Thamsborg, Stig Milan; Kringel, Helene

    2015-01-01

    Eggs of the pig whipworm, Trichuris suis ova (TSO), are currently tested in human clinical trials for their potential immunomodulatory capacity. The biological potency of TSO (egg viability and infectivity) is traditionally assessed in Göttingen minipigs as the establishment of intestinal larvae...... after inoculation with a known number of eggs. To minimize testing in animal models, development of an in vitro egg hatching assay is proposed as a reliable, cost-effective, and a faster alternative to test the egg viability. The present study aimed to investigate the influence of different chemical......, physical, and biological factors on egg hatching. Thus, in a series of experiments and in different combinations, the eggs were stimulated with glass beads, artificial gastric juice, bile salt and trypsin solution, fermentation gut medium, or stimulated with mucosal scrapings from the ileum and the large...

  7. In vitro systems: standardization of endpoints

    International Nuclear Information System (INIS)

    Dewey, W.C.

    1979-01-01

    Principles are discussed for utilizing cell culture systems to assay for interactions between drugs and radiation. Emphasis is based on the necessity of using synchronous cultures to determine whether the interaction is independent, additive, or synergistic, and to determine the effect of drugs on recovery from sublethal x-ray damage (SLD). Furthermore, in studies of drug effects on SLD, adequate controls must be included to distinguish between effects associated with the interaction of 2 x-ray doses and the effects associated with interaction of a second x-ray dose with prior drug exposure. Finally, different methods of expressing drug exposure are reviewed, and associated problems related to predicting in vivo effects from in vitro results are mentioned

  8. In vitro digestibility of banana starch cookies.

    Science.gov (United States)

    Bello-Pérez, Luis A; Sáyago-Ayerdi, Sonia G; Méndez-Montealvo, Guadalupe; Tovar, Juscelino

    2004-01-01

    Banana starch was isolated and used for preparation of two types of cookies. Chemical composition and digestibility tests were carried out on banana starch and the food products, and these results were compared with corn starch. Ash, protein, and fat levels in banana starch were higher than in corn starch. The high ash amount in banana starch could be due to the potassium content present in this fruit. Proximal analysis was similar between products prepared with banana starch and those based on corn starch. The available starch content of the banana starch preparation was 60% (dmb). The cookies had lower available starch than the starches while banana starch had lower susceptibility to the in vitro alpha-amylolysis reaction. Banana starch and its products had higher resistant starch levels than those made with corn starch.

  9. In vitro prebiotic effects of seaweed polysaccharides

    Science.gov (United States)

    Chen, Xiaolin; Sun, Yuhao; Hu, Linfeng; Liu, Song; Yu, Huahua; Xing, Rong'e.; Li, Rongfeng; Wang, Xueqin; Li, Pengcheng

    2017-09-01

    Although prebiotic activities of alginate and agar oligosaccharides isolated from seaweeds have been reported, it remains unknown whether seaweed polysaccharides have prebiotic activity. In this study, we isolated polysaccharides from four species of seaweeds, such as Grateloupia filicina (GFP), Eucheuma spinosum (ESP), Ulva pertusa (UPP), and Ascophyllum nodosum (ANP), and characterized their structures and prebiotic effects in vitro. The results showed that these polysaccharides were different in total sugar and sulfate contents as well as monosaccharide composition. GFP and ESP significantly promoted bifidobacterium proliferation and 0.1% ESP and 0.4% GFP resulted in the highest proliferation rates of beneficial bacteria, whereas UPP and ANP inhibited the growth of beneficial bacteria at all tested concentrations (0.1%-0.5%). The different behaviors of the four seaweed-originated polysaccharides might be reflected by differences in monosaccharide composition and structure. Therefore, polysaccharides isolated from GFP and ESP could be utilized as prebiotics. However, more studies must be carried out in vivo.

  10. Chitosan: collagen sponges. In vitro mineralization

    International Nuclear Information System (INIS)

    Martins, Virginia da C.A.; Silva, Gustavo M.; Plepis, Ana Maria G.

    2011-01-01

    The regeneration of bone tissue is a problem that affects many people and scaffolds for bone tissue growth has been widely studied. The aim of this study was the in vitro mineralization of chitosan, chitosan:native collagen and chitosan:anionic collagen sponges. The sponges were obtained by lyophilization and mineralization was made by soaking the sponges in alternating solutions containing Ca 2+ and PO 4 3- . The mineralization was confirmed by infrared spectroscopy, energy dispersive X-ray and X-ray diffraction observing the formation of phosphate salts, possibly a carbonated hydroxyapatite since Ca/P=1.80. The degree of mineralization was obtained by thermogravimetry calculating the amount of residue at 750 deg C. The chitosan:anionic collagen sponge showed the highest degree of mineralization probably due to the fact that anionic collagen provides additional sites for interaction with the inorganic phase. (author)

  11. In vitro rootting of Dioscoreas sp.

    Directory of Open Access Journals (Sweden)

    Irma Quintero

    2003-07-01

    Full Text Available The Universidad de Córdoba s Vegetal Tissue Culture Laboratory evaluated the effect of naphthalenacetic acid (NAA on in vitro rooting of three yam cultivars (Dioscorea sp. in 2000. The effect of four hormone levels (0, 0.3, 0.6 and 0.9 mg/1 was studied on three yam cultivars (Diamantes-22,003 and 005. A random experimental design was used employing 4x3 factorial arrangement and 20 repetitions; each experimental unit consisted of a glass receptacle containing the culture medium and the explant (one segment nodal. The variables considered were the number of roots and their thickness, culture medium oxidation and callus production. Findings showed that both the hormone and genotype had an effect on all those variables considered in the study and interaction was significant (P

  12. Biofilms of vaginal Lactobacillus in vitro test.

    Science.gov (United States)

    Wei, Xiao-Yu; Zhang, Rui; Xiao, Bing-Bing; Liao, Qin-Ping

    2017-01-01

    This paper focuses on biofilms of Lactobacillus spp. - a type of normal flora isolated from healthy human vaginas of women of childbearing age; thereupon, it broadens the research scope of investigation of vaginal normal flora. The static slide culture method was adopted to foster biofilms, marked by specific fluorescence staining. Laser scanning confocal and scanning electron microscopy were used to observe the microstructure of the biofilms. Photographs taken from the microstructure were analysed to calculate the density of the biofilms. The body of Lactobacillus spp., though red, turned yellow when interacting with the green extracellular polysaccharides. The structure of the biofilm and aquaporin within the biofilm were imaged. Lactobacillus density increases over time. This study provides convincing evidence that Lactobacillus can form biofilms and grow over time in vitro. This finding establishes an important and necessary condition for selecting proper strains for the pharmaceutics of vaginal ecology.

  13. In vitro hydroxyapatite adsorbed salivary proteins

    International Nuclear Information System (INIS)

    Vitorino, Rui; Lobo, Maria Joao C.; Duarte, Jose; Ferrer-Correia, Antonio J.; Tomer, Kenneth B.; Dubin, Joshua R.; Domingues, Pedro M.; Amado, Francisco M.L.

    2004-01-01

    In spite of the present knowledge about saliva components and their respective functions, the mechanism(s) of pellicle and dental plaque formation have hitherto remained obscure. This has prompted recent efforts on in vitro studies using hydroxyapatite (HA) as an enamel model. In the present study salivary proteins adsorbed to HA were extracted with TFA and EDTA and resolved by 2D electrophoresis over a pH range between 3 and 10, digested, and then analysed by MALDI-TOF/TOF mass spectrometry and tandem mass spectrometry. Nineteen different proteins were identified using automated MS and MS/MS data acquisition. Among them, cystatins, amylase, carbonic anhydrase, and calgranulin B, were identified

  14. In vitro diagnosis of sepsis: a review

    Directory of Open Access Journals (Sweden)

    Guido M

    2016-03-01

    Full Text Available Marcello Guido,1 Maria Rosaria Tumolo,2 Antonella De Donno,1 Tiziano Verri,3 Francesca Serio,1 Francesco Bagordo,1 Antonella Zizza2 1Laboratory of Hygiene, Department of Biological and Environmental Sciences and Technologies, Faculty of Sciences, University of Salento, Lecce, Italy; 2National Research Council, Institute of Clinical Physiology, 3Laboratory of Physiology, Department of Biological and Environmental Sciences and Technologies, Faculty of Sciences, University of Salento, Lecce, ItalyAbstract: Sepsis, severe sepsis and septic shock, systemic inflammatory response, and other related manifestations represent a relevant medical problem with high morbidity and mortality, despite the improvements in diagnosis, treatment, and preventive measures over the last few decades. The limited knowledge of the pathophysiology in association with the lack of in vitro diagnostic methods for the certain and quick determination of the causative microbiological agents and their antibiotic resistance means the condition is still critical and of high impact in health care. The current gold standard method to detect the sepsis-causing pathogens, which is based on blood culture, is still insufficiently sensitive and slow. The new culture-independent molecular biology-based techniques can lead to the identification of a broad range of microorganisms and resistance markers within a few hours and with high sensitivity and specificity; nevertheless, limitations of, for example, the polymerase chain reaction-based methods still hamper their application in the clinical routine. This review summarizes the in vitro diagnostic methods and their approach in the clinical diagnosis of the bloodstream infections, and explores their advantages and disadvantages at the current state of the art. A quick analysis of the future prospective in multiplex technologies for microbiological diagnosis of sepsis is also provided. Keywords: PCR, PCR/ESI-MS, microarray, MALDI-TOF, next

  15. In Vitro Conservation of Sweet Potato Genotypes

    Directory of Open Access Journals (Sweden)

    Maria de Fátima Arrigoni-Blank

    2014-01-01

    Full Text Available The aim of this study was to develop a protocol for the in vitro conservation of sweet potato genotypes using the slow growth technique. The first experiment was conducted in a 4×5×2 factorial scheme, testing four genotypes (IPB-007, IPB-052, IPB-072, and IPB-137, five concentrations of abscisic acid (ABA (0.0, 1.0, 2.0, 4.0, and 8.0 mg·L−1, and two temperatures (18 and 25°C. The second experiment was conducted in a 4×3×3 factorial scheme at 18°C, testing four genotypes (IPB-007, IPB-052, IPB-072, and IPB-137, three variations of MS salts (50, 75, and 100%, and three concentrations of sucrose (10, 20, and 30 g·L−1. Every three months, we evaluated the survival (%, shoot height, and shoot viability. In vitro conservation of the sweet potato genotypes IPB-052 and IPB-007 was obtained over three and six months, respectively, using MS medium plus 2.0 mg·L−1 of ABA at either 18 or 25°C. Genotypes IPB-072 and IPB-137 can be kept for three and six months, respectively, in MS medium without ABA at 18°C. It is possible to store IPB-052 and IPB-072 for six months and IPB-007 and IPB-137 for nine months using 30 g·L−1 of sucrose and 50% MS salts.

  16. Novel in Vitro Model for Keratoconus Disease

    Directory of Open Access Journals (Sweden)

    James D. Zieske

    2012-11-01

    Full Text Available Keratoconus is a disease where the cornea becomes cone-like due to structural thinning and ultimately leads to compromised corneal integrity and loss of vision. Currently, the therapeutic options are corrective lenses for early stages and surgery for advanced cases with no in vitro model available. In this study, we used human corneal fibroblasts (HCFs and compared them to human Keratoconus fibroblasts (HKCs cultured in a 3-dimensional (3D model, in order to compare the expression and secretion of specific extracellular matrix (ECM components. For four weeks, the cells were stimulated with a stable Vitamin C (VitC derivative ± TGF-β1 or TGF-β3 (T1 and T3, respectively. After four weeks, HKCs stimulated with T1 and T3 were significantly thicker compared with Control (VitC only; however, HCF constructs were significantly thicker than HKCs under all conditions. Both cell types secreted copious amounts of type I and V collagens in their assembled, aligned collagen fibrils, which increased in the degree of alignment upon T3 stimulation. In contrast, only HKCs expressed high levels of corneal scarring markers, such as type III collagen, which was dramatically reduced with T3. HKCs expressed α-smooth muscle actin (SMA under all conditions in contrast to HCFs, where T3 minimized SMA expression. Fast Fourier transform (FFT data indicated that HKCs were more aligned when compared to HCFs, independent of treatments; however, HKC’s ECM showed the least degree of rotation. HKCs also secreted the most aligned type I collagen under T3 treatment, when compared to any condition and cell type. Overall, our model for Keratoconus disease studies is the first 3D in vitro tissue engineered model that can mimic the Keratoconus disease in vivo and may be a breakthrough in efforts to understand the progression of this disease.

  17. Iron inhibits hydroxyapatite crystal growth in vitro.

    Science.gov (United States)

    Guggenbuhl, Pascal; Filmon, Robert; Mabilleau, Guillaume; Baslé, Michel F; Chappard, Daniel

    2008-07-01

    Hemochromatosis is a known cause of osteoporosis in which the pathophysiology of bone loss is largely unknown and the role of iron remains questionable. We have investigated the effects of iron on the growth of hydroxyapatite crystals in vitro on carboxymethylated poly(2-hydroxyethyl methacrylate) pellets. This noncellular and enzyme-independent model mimics the calcification of woven bone (composed of calcospherites made of hydroxyapatite crystals). Polymer pellets were incubated with body fluid containing iron at increasing concentrations (20, 40, 60 micromol/L). Hydroxyapatite growth was studied by chemical analysis, scanning electron microscopy, and Raman microscopy. When incubated in body fluid containing iron, significant differences were observed with control pellets. Iron was detected at a concentration of 5.41- to 7.16-fold that of controls. In pellets incubated with iron, there was a approximately 3- to 4-fold decrease of Ca and P and a approximately 1.3- to 1.4-fold increase in the Ca/P ratio. There was no significant difference among the iron groups of pellets, but a trend to a decrease of Ca with the increase of iron concentration was noted. Calcospherite diameters were significantly lower on pellets incubated with iron. Raman microspectroscopy showed a decrease in crystallinity (measured by the full width of the half height of the 960 Deltacm(-1) band) with a significant increase in carbonate substitution (measured by the intensity ratio of 1071 to 960 Deltacm(-1) band). Energy dispersive x-ray analysis identified iron in the calcospherites. In vitro, iron is capable to inhibit bone crystal growth with significant changes in crystallinity and carbonate substitution.

  18. Solving the Issue of Restenosis After Stenting of Intracranial Stenoses: Experience with Two Thin-Strut Drug-Eluting Stents (DES)—Taxus Element™ and Resolute Integrity™

    Energy Technology Data Exchange (ETDEWEB)

    Kurre, Wiebke, E-mail: wiebke.kurre@gmx.de; Aguilar-Pérez, Marta [Klinikum Stuttgart, Klinik für Diagnostische und Interventionelle Neuroradiologie (Germany); Fischer, Sebastian [Universitätsklinikum Knappschaftskrankenhaus Bochum GmbH, Institut für Diagnostische und Interventionelle Radiologie, Neuroradiologie und Nuklearmedizin (Germany); Arnold, Guy [Klinikverbund Südwest, Klinikum Sindelfingen, Klinik für Neurologie (Germany); Schmid, Elisabeth; Bäzner, Hansjörg [Klinikum Stuttgart, Klinik für Neurologie (Germany); Henkes, Hans [Klinikum Stuttgart, Klinik für Diagnostische und Interventionelle Neuroradiologie (Germany)

    2015-06-15

    PurposeThin-strut, flexible DES are suitable for intracranial stenting and may improve long-term vessel patency. The purpose of this study was to report our experience with two new-generation DES for the treatment of intracranial atherosclerotic disease.Pati