WorldWideScience

Sample records for coronary perfusion pressure

  1. Coronary oscillatory flow amplitude is more affected by perfusion pressure than ventricular pressure.

    Science.gov (United States)

    Krams, R; Sipkema, P; Westerhof, N

    1990-06-01

    In this study on the isolated, maximally vasodilated, blood-perfused cat heart we investigated the relation between left ventricular developed pressure (delta Piv) and coronary oscillatory flow amplitude (diastolic minus systolic flow, delta F) at different levels of constant perfusion pressure (Pp). We hypothesized that the effect of cardiac contraction on the phasic flow results from the changing elastic properties of cardiac muscle. The coronary vessel compartment can, as can the left ventricular lumen compartment, be described by a time-varying elastance. This concept predicts that the effect of left ventricular pressure on delta F is small, whereas the effect of Pp is considerable. Both the waterfall model and the intramyocardial pump model predict the inverse. The relation between delta Piv and delta F at a Pp of 10 kPa is delta F = (4.71 +/- 3.08).delta Piv + 337 +/- 75 (slope in ml.min-1.100 g-1.kPa-1 and intercept in ml.min-1.100 g-1; n = 7); the relation between (constant levels of) Pp and delta F at a constant delta Piv of 10 kPa is delta F = 51.Pp + 211 (slope in ml.min-1.100 g-1.kPa-1 and intercept in ml.min-1.100 g-1; n = 6). The differences in slope are best predicted by the time-varying elastance concept.

  2. Visualization of myocardial perfusion derived from coronary anatomy

    NARCIS (Netherlands)

    Termeer, M.A.; Bescos, J.O.; Breeuwer, M.; Vilanova, A.; Gerritsen, F.A.; Gröller, M.E.; Nagel, Eike

    2008-01-01

    Visually assessing the effect of the coronary artery anatomy on the perfusion of the heart muscle in patients with coronary artery disease remains a challenging task. We explore the feasibility of visualizing this effect on perfusion using a numerical approach. We perform a computational simulation

  3. Patient-specific coronary blood supply territories for quantitative perfusion analysis

    Science.gov (United States)

    Zakkaroff, Constantine; Biglands, John D.; Greenwood, John P.; Plein, Sven; Boyle, Roger D.; Radjenovic, Aleksandra; Magee, Derek R.

    2018-01-01

    Abstract Myocardial perfusion imaging, coupled with quantitative perfusion analysis, provides an important diagnostic tool for the identification of ischaemic heart disease caused by coronary stenoses. The accurate mapping between coronary anatomy and under-perfused areas of the myocardium is important for diagnosis and treatment. However, in the absence of the actual coronary anatomy during the reporting of perfusion images, areas of ischaemia are allocated to a coronary territory based on a population-derived 17-segment (American Heart Association) AHA model of coronary blood supply. This work presents a solution for the fusion of 2D Magnetic Resonance (MR) myocardial perfusion images and 3D MR angiography data with the aim to improve the detection of ischaemic heart disease. The key contribution of this work is a novel method for the mediated spatiotemporal registration of perfusion and angiography data and a novel method for the calculation of patient-specific coronary supply territories. The registration method uses 4D cardiac MR cine series spanning the complete cardiac cycle in order to overcome the under-constrained nature of non-rigid slice-to-volume perfusion-to-angiography registration. This is achieved by separating out the deformable registration problem and solving it through phase-to-phase registration of the cine series. The use of patient-specific blood supply territories in quantitative perfusion analysis (instead of the population-based model of coronary blood supply) has the potential of increasing the accuracy of perfusion analysis. Quantitative perfusion analysis diagnostic accuracy evaluation with patient-specific territories against the AHA model demonstrates the value of the mediated spatiotemporal registration in the context of ischaemic heart disease diagnosis. PMID:29392098

  4. Patient satisfaction with coronary CT angiography, myocardial CT perfusion, myocardial perfusion MRI, SPECT myocardial perfusion imaging and conventional coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Feger, S.; Rief, M.; Zimmermann, E.; Richter, F.; Roehle, R. [Freie Universitaet Berlin, Department of Radiology, Charite - Universitaetsmedizin Berlin Campus Mitte, Humboldt-Universitaet zu Berlin, Berlin (Germany); Dewey, M. [Freie Universitaet Berlin, Department of Radiology, Charite - Universitaetsmedizin Berlin Campus Mitte, Humboldt-Universitaet zu Berlin, Berlin (Germany); Institut fuer Radiologie, Berlin (Germany); Schoenenberger, E. [Medizinische Hochschule Hannover, Department of Medicine, Hannover (Germany)

    2015-07-15

    To evaluate patient acceptance of noninvasive imaging tests for detection of coronary artery disease (CAD), including single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI), stress perfusion magnetic resonance imaging (MRI), coronary CT angiography (CTA) in combination with CT myocardial stress perfusion (CTP), and conventional coronary angiography (CCA). Intraindividual comparison of perception of 48 patients from the CORE320 multicentre multinational study who underwent rest and stress SPECT-MPI with a technetium-based tracer, combined CTA and CTP (both with contrast agent, CTP with adenosine), MRI, and CCA. The analysis was performed by using a validated questionnaire. Patients had significantly more concern prior to CCA than before CTA/CTP (p < 0.001). CTA/CTP was also rated as more comfortable than SPECT-MPI (p = 0.001). Overall satisfaction with CT was superior to that of MRI (p = 0.007). More patients preferred CT (46 %; p < 0.001) as a future diagnostic test. Regarding combined CTA/CTP, CTP was characterised by higher pain levels and an increased frequency of angina pectoris during the examination (p < 0.001). Subgroup analysis showed a higher degree of pain during SPECT-MPI with adenosine stress compared to physical exercise (p = 0.016). All noninvasive cardiac imaging tests are well accepted by patients, with CT being the preferred examination. (orig.)

  5. Comparison of Myocardial Perfusion Scintigraphy and Coronary Angiography Results

    Directory of Open Access Journals (Sweden)

    Umut Elboga

    2017-05-01

    Full Text Available Aim: Coronary artery disease (CAD is one of the most frequent causes of mortality and morbidity worldwide. Coronary angiography is the gold standard for the anatomical diagnosis of coronary artery stenosis. Myocardial Perfusion Scintigraphy (MPS is a non-invasive imaging modality used for the diagnosis of CAD. In this study, we aimed to compare the findings of MPS and coronary angiogram. Material and Method: Eighty-one patients (37 males, 44 females; mean age 55 ± 10.95 years with angina and detected perfusion defects on MPS were included in this study. All of the patients underwent coronary angiogram. A narrowing %u2265 50% was considered pathological on the coronary angiography. Results: Findings of the coronary angiogram and MPS were compared and found consistent in 51 (63% patients. A coronary narrowing < 50% was detected by coronary angiogram in 4 (5% of the remaining patients. Coronary angiogram was found to be normal in the remaining 26 patients (32% and these patients were evaluated as cardiac syndrome X (CSX known as microvascular angina (MA. Discussion: The findings showed that MPS is superior to coronary angiogram in the early diagnosis of myocardial perfusion disorders at the microvascular level. Therefore, we concluded that MPS should be the primary diagnostic tool to begin treatment before an anatomically large narrowing occurs in the coronaries.

  6. Myocardial perfusion SPECT in diabetic patients for detection of coronary artery disease

    International Nuclear Information System (INIS)

    Saeed, M.A.; Fatima, S.; Fatmi, S.; Kureshi, S.

    2003-01-01

    The aim of this study was to evaluate the efficacy of myocardial SPECT perfusion scan in the diagnosis of coronary artery disease in diabetic patients. A total number of thirty diabetic patients (21 males, 9 females) were included in the study. All the patients had strong risk-factors for coronary artery disease (strong family history, chronic smokers, hyperlipidemia, history of chest pain). All patients underwent coronary angiography and stress/rest myocardial perfusion SPECT scans with Tc-99m MIBI (two days protocol). Twenty two patients had significant coronary artery stenosis and 8 had normal coronary arteries. Myocardial perfusion scintigraphy (MPS) was positive in 19 subjects out of the 22 patients with significant stenosis (Sensitivity 86.4%) and negative (false negative) in only three. Out of 8 patients with normal angiography 7 had normal MPS (Specificity 87.5%) whereas only one patient revealed abnormality in the myocardial perfusion study. When compared with coronary angiography the positive predictive value and negative predictive value for Tc-99m MIBI myocardial perfusion scan was 86.4% and 87.5% respectively. In conclusion, Tc-99m MIBI myocardial perfusion scintigraphy is a useful screening modality for the detection of coronary artery disease in diabetic patients. (author)

  7. Noninvasive assessment of coronary collaterals in man by PET perfusion imaging

    International Nuclear Information System (INIS)

    Demer, L.L.; Gould, K.L.; Goldstein, R.A.; Kirkeeide, R.L.

    1990-01-01

    At present, coronary collateralization cannot be identified or assessed noninvasively in patients. In animal studies, coronary collaterals are associated with coronary steal, defined as a regional fall in perfusion during coronary arteriolar vasodilation. To determine the effect of coronary arteriolar vasodilation on collateral bed perfusion in man, myocardial perfusion imaging was performed before and after pharmacologic coronary vasodilation in patients with coronary artery disease (CAD). Regional myocardial activity of 82 Rb or 13 N ammonia was measured by positron emission tomography (PET) at rest and with intravenous dipyridamole/handgrip stress in 28 patients with angiographic collaterals and in 25 control patients with similar CAD severity by quantitative arteriography. Regional myocardial activity decreased after dipyridamole, indicating coronary steal, in 25 of 28 patients with angiographic collaterals and in only 4 of 25 control patients without angiographic collaterals. These findings suggest that developed collaterals are associated with myocardial steal in patients with CAD, allowing potential use of PET for non-invasive identification of coronary collateralization

  8. Myocardial perfusion studies in coronary diseases

    International Nuclear Information System (INIS)

    Mut, Fernando

    1994-01-01

    For detecting in precocious form a coronary disease is necessary to apply a diagnostic techniques. The main considerations to be indicated in the present work are: physiological considerations, myocardial perfusion studies with radiotracers such as Talio 201, 99mTc, MIBI, 99mTc-Teboroxima, 99mTc-Fosfinas, instrumentation for obtain good images,proceedings protocols, studies interpretation, standards, SPECT, anomalies standards, coronary diseases

  9. Myocardial Ischaemia, Coronary Atherosclerosis and Pulmonary Pressure Elevation in Antiphospholipid Syndrome Patients.

    Science.gov (United States)

    Padjas, Agnieszka; Płazak, Wojciech; Celińska-Lowenhoff, Magdalena; Mazurek, Adam; Perricone, Carlo; Podolec, Piotr; Musiał, Jacek

    2016-01-01

    Thrombotic events in antiphospholipid syndrome (APS) involve venous and arterial circulation with the possible involvement of coronary or pulmonary microcirculation. To evaluate the influence of antiphospholipid antibodies (aPL) and on myocardial ischaemia assessed by single-photon emission computerized tomography (SPECT), coronary atherosclerosis assessed by multidetector computerized tomography (MDCT) and pulmonary pressure assessed by transthoracic echocardiography (TTE) in patients with primary antiphospholipid syndrome (PAPS). TTE, SPECT (Tc 99m sestamibi) and MDCT-based coronary calcium scoring were performed in 26 consecutive PAPS patients (20 females, 6 males, aged 20-61, mean 39.7) without any signs of other autoimmunological disease and without clinical symptoms of heart disease. Out of 26 patients, TEE showed normal left and right ventricle function in 25 (96.2%) and elevated (≥ 30 mm Hg) right ventricle systolic pressure in 7 (26.9%) patients. SPECT revealed myocardial perfusion defects in 15 (57.7%) patients: exercise-induced in 6 (23.1%) and persistent in 11 (42.3%). MDCT revealed coronary calcifications in 4 (15.4%) patients. The number of plaques ranged from 1 to 11 (median 2), volume 3-201.7 mm³ (median 7), calcium scores 1.3-202.6 (median 5.7). In the group with perfusion defects or coronary calcifications (n = 15), all the patients showed elevated aCL IgG. In most of the relatively young APS patients, without any symptoms of ischemic heart disease, SPECT showed myocardial perfusion defects, and coronary calcifications in 1/6 of them. Right ventricle systolic pressure was elevated in 1/4 of APS patients. These pathologies, well known as cardiovascular risk markers, were associated with elevated levels of the IgG class of both anti-cardiolipin and antiB2 GPI antibodies. Thus, in a high percentage of APS patients, clinically silent myocardial ischaemia, pulmonary pressure elevation and coronary atherosclerosis are present and related to the

  10. Diagnostic performance of coronary CT angiography, stress dual-energy CT perfusion, and stress perfusion single-photon emission computed tomography for coronary artery disease: Comparison with combined invasive coronary angiography and stress perfusion cardiac MRI

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Hyun Woo; Ko, Sung Min; Hwang, Hweung Kon; So, Young; Yi, Jeong Geun [Konkuk University Medical Center, Research Institute of Biomedical Science, Konkuk University School of Medicine, Seoul (Korea, Republic of); Lee, Eun Jeong [Dept. of Nuclear Medicine, Seoul Medical Center, Seoul (Korea, Republic of)

    2017-06-15

    To investigate the diagnostic performance of coronary computed tomography angiography (CCTA), stress dual-energy computed tomography perfusion (DE-CTP), stress perfusion single-photon emission computed tomography (SPECT), and the combinations of CCTA with myocardial perfusion imaging (CCTA + DE-CTP and CCTA + SPECT) for identifying coronary artery stenosis that causes myocardial hypoperfusion. Combined invasive coronary angiography (ICA) and stress perfusion cardiac magnetic resonance (SP-CMR) imaging are used as the reference standard. We retrospectively reviewed the records of 25 patients with suspected coronary artery disease, who underwent CCTA, DE-CTP, SPECT, SP-CMR, and ICA. The reference standard was defined as ≥ 50% stenosis by ICA, with a corresponding myocardial hypoperfusion on SP-CMR. For per-vascular territory analysis, the sensitivities of CCTA, DE-CTP, SPECT, CCTA + DE-CTP, and CCTA + SPECT were 96, 96, 68, 93, and 68%, respectively, and specificities were 72, 75, 89, 85, and 94%, respectively. The areas under the receiver operating characteristic curve (AUCs) were 0.84 ± 0.05, 0.85 ± 0.05, 0.79 ± 0.06, 0.89 ± 0.04, and 0.81 ± 0.06, respectively. For per-patient analysis, the sensitivities of CCTA, DE-CTP, SPECT, CCTA + DE-CTP, and CCTA + SPECT were 100, 100, 89, 100, and 83%, respectively; the specificities were 14, 43, 57, 43, and 57%, respectively; and the AUCs were 0.57 ± 0.13, 0.71 ± 0.11, 0.73 ± 0.11, 0.71 ± 0.11, and 0.70 ± 0.11, respectively. The combination of CCTA and DE-CTP enhances specificity without a loss of sensitivity for detecting hemodynamically significant coronary artery stenosis, as defined by combined ICA and SP-CMR.

  11. Computed tomography angiography and perfusion to assess coronary artery stenosis causing perfusion defects by single photon emission computed tomography

    DEFF Research Database (Denmark)

    Rochitte, Carlos E; George, Richard T; Chen, Marcus Y

    2014-01-01

    AIMS: To evaluate the diagnostic power of integrating the results of computed tomography angiography (CTA) and CT myocardial perfusion (CTP) to identify coronary artery disease (CAD) defined as a flow limiting coronary artery stenosis causing a perfusion defect by single photon emission computed...... emission computed tomography (SPECT/MPI). Sixteen centres enroled 381 patients who underwent combined CTA-CTP and SPECT/MPI prior to conventional coronary angiography. All four image modalities were analysed in blinded independent core laboratories. The prevalence of obstructive CAD defined by combined ICA...... tomography (SPECT). METHODS AND RESULTS: We conducted a multicentre study to evaluate the accuracy of integrated CTA-CTP for the identification of patients with flow-limiting CAD defined by ≥50% stenosis by invasive coronary angiography (ICA) with a corresponding perfusion deficit on stress single photon...

  12. Functional assessment of sequential coronary artery fistula and coronary artery stenosis with fractional flow reserve and stress adenosine myocardial perfusion imaging

    Directory of Open Access Journals (Sweden)

    Kuan Leong Yew

    2015-10-01

    Full Text Available Coronary artery fistula is an abnormal connection between one coronary artery to another coronary artery or cardiac chambers. The coronary artery fistula may cause significant shunting of blood and cause “pseudo-stenosis” or “steal phenomenon”. This will also accentuate pre-existing mild-moderate de novo coronary lesions with resultant greater pressure gradient difference across the lesions. Thus, fractional flow reserve can be a useful tool to guide intervention decision on the coronary artery fistula. There are very few published reports regarding the use of FFR to assess coronary artery fistula. In fact, there is no outcome data regarding the deferment of coronary artery fistula intervention when the FFR is not physiologically significant. This case highlighted the use of FFR to evaluate the functional significance of coronary fistula in the setting of ischemia evaluation and it was proven to be safe to defer intervention with good 3 year clinical outcome. Stress adenosine myocardial perfusion imaging correlated with the FFR result.

  13. Reduced myocardial perfusion reserve in myocardium having coronary artery aneurysm of Kawasaki disease

    International Nuclear Information System (INIS)

    Yoon, S. N.; Lee, D. S.; Choi, J. Y.; Kil, H. R.; Jeong, Z. K.; Lee, M. C.; Ko, C. S.

    1997-01-01

    Kawasaki disease is a systemic vasculitis involving the coronary arteries at early childhood and cause coronary artery aneurysms and thrombotic occlusions. These coronary artery aneurysms were usually transformed later into stenotic or obstructive lesions, however, the majority of these aneurysms, even the giant ones, are known to be associated with normal epicardial coronary flow. Flow reserve is difficult to assess in aneurysmal arteries with echo or angiography. We performed this study to question if there are abnormalities in flow reserve in myocardial tissue with normal epicardial arterial flow on angiography in patients with Kawasaki disease, dipyridamole stress and rest Tc-99m-sestamibi SPECT were performed in 37 patients (28 boys, 9 girls, mean age 6.6 years). We compared SPECT findings with coronary angiography (CAG) findings in 21 patients who did both studies after finding abnormality on echocardiaography. On CAG, aneurysms were found in 26 arteries of 16 patients, i.e., 10 left main arteries, 6 left anterior descending arteries (LAD), 2 left circumflex arteries (LCX), and 8 right coronary arteries (RCA). Localized and segmental stenotic lesions were found in 11 arteries in 9 patients (LAD: 4, LCX: 1, RCA: 6). Eight of the 10 patients with aneurysms had no obvious stenosis. On stress-rest SPECT, 16(43%) out of 37 patients showed normal perfusion and the other 21(57%) showed reversible or persistent decrease. Among 11 stenotic artery territories, 3(27%) showed persistent and/or reversible perfusion defects. The other 8 were normal. Among 26 aneurysmal artery territories, 12 artery territories showe perfusion decrease. Three of the 5 patients with normal CAG showed persistent and/or transient perfusion defects. Among 14 artery territories with perfusion decrease in the 16 patients, 3(21%) could be localized to vascular territory having stenosis of supplying coronary arteries, 12(86%) were related to the coronary artery aneurysms. Two were not related to

  14. Normal myocardial perfusion imaging in the presence of significant coronary artery stenosis

    International Nuclear Information System (INIS)

    Tian Yueqin; He Zuoxiang; Fang Wei; Yang Minfu; Shen Rui

    2007-01-01

    Objective: The aim of this study was to investigate the factors which might result in normal myocardial perfusion imaging in the presence of significant coronary artery stenosis. Methods: One hundred and thirty-three patients [mean age of (59±10) years, 98 men, 35 women] who underwent coronary angiography and myocardial perfusion SPECT were retrospectively analyzed. Results: Forty-six (35%) patients performed adequate bicycle exercise testing and achieved more than 85% of their predicted maximal heart rates; while 87 (65%) patients did not. Eighty-four (63%) patients had single coronary stenosis, 31(23%) two-vessel and 17(13%) three-vessel diseases. The difference in stenosis severity among the vessels in 13 (76%) cases with three-vessel diseases was not more than 20%. There were totally 202 coronary artery stenosis: 93 (46%) in left anterior descending coronary artery (LAD), 52 (26%) left circumflex coronary artery (LCX), 52(26% ) right coronary artery (RCA) and 5 (2%) left main coronary artery (LM) disease. Eighty-six(43%) vessels had 50%-70% stenosis, 100 (49%) >70%-90% and 16(8% )more than 90%. Conclusion: Normal myocardial perfusion imaging with significant coronary artery stenosis can probably due to inadequate exercise, single vessel disease and mild to moderate stenotic lesion. (authors)

  15. Thallium-201 myocardial perfusion imaging during transient coronary occlusion at the time of PTCA

    International Nuclear Information System (INIS)

    Nakagawa, Tatsuya; Sugihara, Hiroki; Inagaki, Suetsugu

    1989-01-01

    To evaluate myocardial perfusion during transient coronary arterial occlusion, thallium-201 was administered intravenously during percutaneous transluminall coronary angioplasty (PTCA) in 12 patients with effort angina, and the resulting perfusion images were compared with those of exercise stress obtained before PTCA. Thallium-201 was injected at the last inflation of an angioplastic baloon and occlusion was maintained for 60 to 90 sec. Three projections of planar images were obtained immediately after PTCA, using a portable gamma camera in an angiography room. These perfusion images obtained during PTCA and exercise were visually interpreted and compared. Myocardial perfusion defects due to the responsible vessel occlusion were observed at early imaging after PTCA, and were fully redistributed three hrs post injection. In 10 patients without angiographically imaged collateral vessels, there were no significatn differences in perfusion between images during PTCA and during exercise. Two patients whose collaterals were observed during coronary angiography before PTCA had higher perfusion scores during PTCA than during exercise. We concluded that intravenous injection of thallium-201 during PTCA is a useful means for assessing alteration of myocardial perfusion due to transient coronary occlusion without increasing the risk of angioplastic procedures, and that it provides more precise information about the jeopardized myocardium, perfused by antegrade blood flow. (author)

  16. Effects of exercise training on coronary transport capacity

    International Nuclear Information System (INIS)

    Laughlin, M.H.

    1985-01-01

    Coronary transport capacity was estimated in eight sedentary control and eight exercise-trained anesthetized dogs by determining the differences between base line and the highest coronary blood flow and permeability-surface area product (PS) obtained during maximal adenosine vasodilation with coronary perfusion pressure constant. The anterior descending branch of the left coronary artery was cannulated and pump- perfused under constant-pressure conditions (approximately equal to 100 Torr) while aortic, central venous, and coronary perfusion pressures, heart rate, electrocardiogram, and coronary flow were monitored. Myocardial extraction and PS of 51 Cr-labeled ethylenediaminetetraacetic acid were determined with the single-injection indicator-diffusion method. The efficacy of the 16 +/- 1 wk exercise training program was shown by significant increases in the succinate dehydrogenase activities of the gastrocnemius, gluteus medialis, and long head of triceps brachii muscles. There were no differences between control and trained dogs for either resting coronary blood flow or PS. During maximal vasodilation with adenosine, the trained dogs had significantly lower perfusion pressures with constant flow and, with constant-pressure vasodilation, greater coronary blood flow and PS. It is concluded that exercise training in dogs induces an increased coronary transport capacity that includes increases in coronary blood flow capacity (26% of control) and capillary diffusion capacity (82% of control)

  17. Stress perfusion magnetic resonance imaging to detect coronary artery lesions in children.

    Science.gov (United States)

    Vijarnsorn, Chodchanok; Noga, Michelle; Schantz, Daryl; Pepelassis, Dion; Tham, Edythe B

    2017-05-01

    Stress perfusion cardiovascular magnetic resonance (CMR) is used widely in adult ischemic heart disease, but data in children is limited. We sought to evaluate feasibility, accuracy and prognostic value of stress CMR in children with suspected coronary artery disease (CAD). Stress CMR was reviewed from two pediatric centers over 5 years using a standard pharmacologic protocol. Wall motion abnormalities, perfusion deficits and late enhancement were correlated with coronary angiogram (CAG) when available, and clinical status at 1 year follow-up for major adverse cardiovascular events (MACE; coronary revascularization, non-fatal myocardial infarction and death due to CAD) was recorded. Sixty-four stress perfusion CMR studies in 48 children (10.9 ± 4.8 years) using adenosine; 59 (92%) and dipyridamole; 5 (8%), were reviewed. Indications were Kawasaki disease (39%), post arterial switch operation (12.5%), post heart transplantation (12.5%), post anomalous coronary artery repair (11%), chest pain (11%), suspected myocarditis or CAD (3%), post coronary revascularization (3%), and others (8%). Twenty-six studies were performed under sedation. Of all studies performed, 66% showed no evidence of ischemia or infarction, 28% had perfusion deficits and 6% had late gadolinium enhancement (LGE) without perfusion deficit. Compared to CAG, the positive predictive value (PPV) of stress CMR was 80% with negative predictive value (NPV) of 88%. At 1 year clinical follow-up, the PPV and NPV of stress CMR to predict MACE were 78 and 98%. Stress-perfusion CMR, in combination with LGE and wall motion-analysis is a feasible and an accurate method of diagnosing CAD in children. In difficult cases, it also helps guide clinical intervention by complementing conventional CAG with functional information.

  18. Computed Tomographic Perfusion Improves Diagnostic Power of Coronary Computed Tomographic Angiography in Women

    DEFF Research Database (Denmark)

    Penagaluri, Ashritha; Higgins, Angela Y.; Vavere, Andrea L

    2016-01-01

    laboratories. Prevalence of flow-limiting CAD defined by invasive coronary angiography equal to 50% or greater with an associated single-photon emission computed tomography myocardial perfusion imaging defect was 45% (114/252) and 23% (30/129) in males and females, respectively. Patient-based diagnostic......Background-Coronary computed tomographic angiography (CTA) and myocardial perfusion imaging (CTP) is a validated approach for detection and exclusion of flow-limiting coronary artery disease (CAD), but little data are available on gender-specific performance of these modalities. In this study, we...... aimed to evaluate the diagnostic accuracy of combined coronary CTA and CTP in detecting flow-limiting CAD in women compared with men.  Methods and Results-Three hundred and eighty-one patients who underwent both CTA-CTP and single-photon emission computed tomography myocardial perfusion imaging...

  19. Myocardial perfusion studies in coronary diseases; Estudios de Perfusion Miocardica en la Enfermedad Coronaria

    Energy Technology Data Exchange (ETDEWEB)

    Mut, Fernando [Universidad de la Republica, Montevideo (Uruguay)

    1994-12-31

    For detecting in precocious form a coronary disease is necessary to apply a diagnostic techniques. The main considerations to be indicated in the present work are: physiological considerations, myocardial perfusion studies with radiotracers such as Talio 201, 99mTc, MIBI, 99mTc-Teboroxima, 99mTc-Fosfinas, instrumentation for obtain good images,proceedings protocols, studies interpretation, standards, SPECT, anomalies standards, coronary diseases.

  20. Specific perfusion pattern in stress 201Tl myocardial scintigraphy of left main coronary artery disease

    International Nuclear Information System (INIS)

    Wakasugi, Shigetoshi; Shibata, Nobuhiko; Kobayashi, Tohru; Fudemoto, Yoshiyuki; Hasegawa, Yoshihisa; Nakano, Shunichi

    1986-01-01

    The usefulness of stress 201 Tl myocardial scintigraphy for identifying left main coronary artery disease was evaluated with data from 23 patients with 50% or more narrowing of the left main coronary artery and 56 patients with 75% or more narrowing of the major coronary arteries but without left main coronary artery involvement (no left main coronary artery disease). Quantitative evaluation of stress perfusion scintigrams in all five patients with narrowing of the left main coronary artery of 90% or more showed a characteristic perfusion pattern (left main pattern) of extensive homogeneous defect over the whole anterolateral segment and simultaneous defects in all radii of the high anteroseptal and high posterolateral segments. On the other hand, such a perfusion pattern was noted in only 1 of 18 patients with less than 90% stenosis of the left main coronary artery and in only 1 of 56 patients with no left coronary artery disease. (orig.)

  1. Evaluation of hemodynamic significance of coronary fistulae. Diagnostic integration between coronary angiography and stress/rest myocardial scintigraphy

    International Nuclear Information System (INIS)

    Rubini, G.; Sebastiani, M.

    2000-01-01

    It is here reported on the importance of the integration of data obtained from digital coronary angiography and stress/rest 99m Tc sestamibi myocardial perfusion single photon emission tomography in evaluationing the hemodynamic significance of coronary arteriovenous fistulae. Coronary fistulae were detected with coronary angiography in 9 patients. All patients underwent clinical examination, trans thoracic echocardiography, stress electrocardiogram and stress/rest 99m Tc sestamibi myocardial perfusion single photon emission tomography. Stress/rest 99m Tc sestamibi myocardial perfusion single photon tomography and stress electrocardiogram showed stress-induced myocardial ischemia in 2 patients. The first patient with familial predisposition and risk factors for ischemic heart disease presented a mesocardic heart murmur on clinical examination. At stress ECG (125 Watt, 153 b/m max frequency 93%, arterial pressure 230 mmHg, max frequency pressure product 35200) ischemic alterations were recorded at the first minute of the second stage of the Bruce protocol. Coronary angiography detected a circumflex artery fistula in the coronary sinus. Stress/rest 99m Tc sestamibi myocardial perfusion single photon emission tomography for the evaluation of stress/rest perfusion detected a reversible perfusion defect of the proximal portion of the posterolateral and lateral walls, thus confirming the hemodynamic importance of the flow through the fistula during stress cycloergometric testing. In the second patient familial predisposition to ischemic heart disease and previous inferior wall myocardial infarction and non-significant stress ECG, coronary angiography identified a seclusive stenosis of the right coronary artery and anomaly between the anterior interventricular artery and the left pulmonary artery. The presence of the contrast medium in the left pulmonary artery identified a flow from the left ventricle to the left pulmonary artery. Good angiographic results were obtained

  2. Prognostic value of coronary blood flow velocity and myocardial perfusion in intermediate coronary Narrowings and multivessel disease

    NARCIS (Netherlands)

    Chamuleau, SAJ; Tio, RA; de Cock, CC; de Muinck, ED; Pijls, NHJ; van Eck-Smit, BLF; Koch, KT; Meuwissen, M; Dijkgraaf, MGW; Verberne, HJ; van Liebergen, RAM; Laarman, GJ; Tijssen, JGP; Piek, JJ; de Jong, A.

    2002-01-01

    OBJECTIVES This study aimed to investigate the roles of intracoronary derived coronary flow velocity reserve (CFVR) and myocardial perfusion scintigraphy (single photon emission computed tomography, or SPECT) for management of an intermediate lesion in patient, with multivessel coronary artery

  3. Regional myocardial perfusion of cardioplegic solutions

    International Nuclear Information System (INIS)

    Eugene, J.; Lyons, K.P.; Ott, R.A.; Gelezunas, V.L.; Chang, C.W.; Kowall, M.G.; Haiduc, N.J.

    1987-01-01

    We compared the regional myocardial perfusion of blood cardioplegic solution (BCP) and crystalloid cardioplegic solution (CCP) in 14 mongrel dogs. Cardiopulmonary bypass was established at 28 degrees C, and a hydraulic occluder was placed around the proximal left anterior descending (LAD) coronary artery. In group 1 (N = 7) collateral coronary arteries were ligated; in group 2 (N = 7) collateral coronary arteries were left in situ. After the aorta was clamped, BCP and CCP were alternately perfused at 200 ml/min. The occluder was inflated to produce moderate, severe, and critical LAD stenosis, and regional perfusion was measured by xenon-133 washout with the Silicon Avalanche Radiation Detector. BCP infusion produced a consistently higher aortic pressure, but CCP flow was better than BCP flow under all conditions, particularly without coronary collaterals. Regional myocardial perfusion of CCP is superior to BCP

  4. Perfusion-induced changes in cardiac contractility depend on capillary perfusion.

    Science.gov (United States)

    Dijkman, M A; Heslinga, J W; Sipkema, P; Westerhof, N

    1998-02-01

    The perfusion-induced increase in cardiac contractility (Gregg phenomenon) is especially found in heart preparations that lack adequate coronary autoregulation and thus protection of changes in capillary pressure. We determined in the isolated perfused papillary muscle of the rat whether cardiac muscle contractility is related to capillary perfusion. Oxygen availability of this muscle is independent of internal perfusion, and perfusion may be varied or even stopped without loss of function. Muscles contracted isometrically at 27 degrees C (n = 7). During the control state stepwise increases in perfusion pressure resulted in all muscles in a significant increase in active tension. Muscle diameter always increased with increased perfusion pressure, but muscle segment length was unaffected. Capillary perfusion was then obstructed by plastic microspheres (15 microns). Flow, at a perfusion pressure of 66.6 +/- 26.2 cmH2O, reduced from 17.6 +/- 5.4 microliters/min in the control state to 3.2 +/- 1.3 microliters/min after microspheres. Active tension developed by the muscle in the unperfused condition before microspheres and after microspheres did not differ significantly (-12.8 +/- 29.4% change). After microspheres similar perfusion pressure steps as in control never resulted in an increase in active tension. Even at the two highest perfusion pressures (89.1 +/- 28.4 and 106.5 +/- 31.7 cmH2O) that were applied a significant decrease in active tension was found. We conclude that the Gregg phenomenon is related to capillary perfusion.

  5. Regional glucose utilization in infarcted and remote myocardium: its relation to coronary anatomy and perfusion.

    Science.gov (United States)

    Fragasso, G; Chierchia, S L; Landoni, C; Lucignani, G; Rossetti, E; Sciammarella, M; Vanoli, G E; Fazio, F

    1998-07-01

    We studied the relationship between coronary anatomy, perfusion and metabolism in myocardial segments exhibiting transient and persistent perfusion defects on stress/rest 99Tcm-MIBI single photon emission tomography in 35 patients (31 males, 4 females, mean age 56 +/- 7 years) with a previous myocardial infarction. Quantitative coronary angiography and assessment of myocardial perfusion reserve and glucose metabolism were performed within 1 week of one another. Perfusion was assessed by SPET after the intravenous injection of 740 MBq of 99Tcm-MIBI at rest and after exercise. Regional myocardial glucose metabolism was assessed by position emission tomography at rest (200 MBq of 18F-2-deoxyglucose, FDG) after an overnight fast with no glucose loading. All 35 patients exhibited persistent perfusion defects consistent with the clinically identified infarct site, and 27 (77%) also showed various degrees of within-infarct FDG uptake; 11 patients developed exercise-induced transient perfusion defects within, or in the vicinity of, 15 infarct segments and resting FDG uptake was present in 10 of these segments (67%). Five patients also showed exercise-induced transient perfusion defects in nine segments remote from the site of infarct: resting FDG uptake was present in six of these regions (67%). Finally, nine patients had increased glucose uptake in non-infarcted regions not showing transient perfusion defects upon exercise testing and perfused by coronary arteries with only minor irregularities. Our results confirm the presence of viable tissue in a large proportion of infarct sites. Moreover, FDG uptake can be seen in regions perfused by coronary arteries showing minor irregularities, not necessarily resulting in detectable transient perfusion defects on a MIBI stress scan. Since the clinical significance of such findings is not clear, further studies should be conducted to assess the long-term evolution of perfusion, function and metabolism in non

  6. Thallium - 201 miocardial perfusion scintigraphy in patients with mitral valve prolapse, with and without coronary artery disease

    International Nuclear Information System (INIS)

    Moraes, A.G. de; Sousa, J.E.M.R.; Thom, A.F.; Martins, L.R.F.; Meneghelo, R.S.; Pimentel Filho, W.A.; Marioni Filho, H.; Gimenes, V.M.L.; Pontes Junior, S.C.

    1981-01-01

    Thirty patients with precordial pain and mitral valve prolapse diagnosed by cineangiography and M-mode echocardiography were submitted to Thallium-201 myocardial stress perfusion scintillography. They were divided into two groups: group I - eighteen patients with mitral valve prolapse and normal coronary arteries, of which ten presented positive exercise stress test (55.6%); eight patients had a negative exercise test. Thallium-201 myocardial stress perfusion scintillagraphy was normal in 14 (77.8%) patients, and four with positive stress perfursion scintillography, (three with inferior perfusion defects and one with a lateral one); group II - twelve patients with mitral valve prolapse and severe coronary artery disease (stenosis >= 60% in at least one main vessel of the coronary circulation), of which nine presented positive exercise stress test (75%) and three negative. Thallium-201 exercise myocardial perfusion scintillography was abnormal in nine (75%), six with stress induced ischemia and three with resting defect. Myocardial perfusion scintillography with Thallium-201 was more sensitive to detect the presence of coronary artery disease in patients with mitral valve prolapse (MVP) than the exercise stress test in spite of the fact that a small number of patients (22%) with MVP and normal coronary arteries exhibited abnormal myocardial stress perfusion during scintillography. (Author) [pt

  7. An attempt of thallium-201 myocardial perfusion imaging during transient coronary arterial occlusion by PTCA

    International Nuclear Information System (INIS)

    Nakagawa, Tatsuya; Sugihara, Hiroki; Katahira, Toshio

    1989-01-01

    To evaluate the myocardial perfusion during transient coronary occlusion, we attempted to obtain the myocardial scintigraphy during percutaneous transluminal coronary angioplasty (PTCA). Tl-201 was injected at the last inflation of angioplastic balloon and occlusion was kept on for 60 sec. Planar images or SPECT were obtained immediately after PTCA. With this protocol, myocardial perfusion defects were observed during PTCA and fully redistributed 3 hours after Tl injection. Extent of ischemic lesions were almost same as that observed during exercise in two cases without collateral vessels. In a case with well visualized collateral vessels, perfusion defect was smaller in PTCA images than that in exercise stressed images. We conclude that intravenous injection of Tl-201 during PTCA is useful to assess the alteration of myocardial perfusion due to transient coronary occlusion without increasing the risk of angioplastic procedure. (author)

  8. Myocardial CT perfusion imaging and SPECT for the diagnosis of coronary artery disease

    DEFF Research Database (Denmark)

    George, Richard T; Mehra, Vishal C; Chen, Marcus Y

    2014-01-01

    %, respectively, for SPECT. CONCLUSION: The overall performance of myocardial CT perfusion imaging in the diagnosis of anatomic CAD (stenosis ≥50%), as demonstrated with the Az, was higher than that of SPECT and was driven in part by the higher sensitivity for left main and multivessel disease.......PURPOSE: To compare the diagnostic performance of myocardial computed tomographic (CT) perfusion imaging and single photon emission computed tomography (SPECT) perfusion imaging in the diagnosis of anatomically significant coronary artery disease (CAD) as depicted at invasive coronary angiography....... MATERIALS AND METHODS: This study was approved by the institutional review board. Written informed consent was obtained from all patients. Sixteen centers enrolled 381 patients from November 2009 to July 2011. Patients underwent rest and adenosine stress CT perfusion imaging and rest and either exercise...

  9. The impact of exercise myocardial perfusion SPECT imaging on the selection of patients for coronary angiography

    International Nuclear Information System (INIS)

    Song Liping; He Zuoxiang; Liu Xiujie; Shi Rongfang; Liu Yunzhong; Tian Yueqin; Zhang Xiaoli; Qin Xuewen; Chen Jilin; Gao Runlin

    2001-01-01

    Objective: Exercise 99 Tc m -MIBI myocardial perfusion SPECT is accurate for the diagnosis of coronary artery disease (CAD). This study assessed the impact of exercise myocardial perfusion imaging on the selection of patients for coronary angiography. Methods: 2188 consecutive patients who underwent exercise myocardial perfusion SPECT in authors' department in 1999 were retrospectively analyzed. Among them, 1807 were men, 381 women (average age: 53.5 +- 7.2 years). Overall, exercise myocardial SPECT was normal in 1731 patients, abnormal in 359 cases, and equivocal in 98 patients. There were 141 patients who underwent CAG within 60 days after myocardial SPECT. Results: Overall, 12% of the patients with abnormal SPECT imaging underwent coronary angiography, but only 5% of the patients with a normal SPECT imaging did (P < 0.001). Among these 141 patients who underwent coronary angiography, significant coronary stenosis was present in 91% of the patients who had had an abnormal SPECT imaging, but only 8% of those who had had a normal SPECT imaging (P < 0.001). In those patients who underwent coronary angiography, revascularization rate was 25% for the patients with abnormal SPECT imaging, but only 1% for the patients with a normal SPECT imaging. Conclusion: The results of exercise myocardial perfusion SPECT have a significant impact on the selection of patients for coronary angiography and revascularization

  10. Homocysteine plasma levels in patients suspected coronary artery disease: Relation to myocardial perfusion image

    International Nuclear Information System (INIS)

    Yao, Z.Y.; He, Q.; Qu, W.

    2002-01-01

    Purpose: Although there is considerable epidemiologic evidence for a relationship between plasma homocysteine (Hcy) levels and coronary artery disease (CAD), not all studies, especially prospective ones have shown such a relationship. The purpose of this study was to investigate a possible association between Hcy plasma levels and myocardial perfusion defect by SPECT in patients suspected CAD. Methods and Materials: A cohort of 238 patients suspected CAD (age: 60.65±10.43, male to female: 172: 66) was examined for Hcy, tetrahydrofolic acid (FH4), vitamine B12 and coronary angiography (CAG). Furthermore, 42 patients also underwent 99m Tc-MIBI myocardial perfusion images (MPI) to assess the myocardial perfusion. Results: There were 69 patients with normal CAG and 63, 60, 42 and 4 patients with 1 vessel, two vessel, 3 vessel and left main coronary stenosis. The plasma Hcy of this group was significantly increased, p 0.05. In patients with >=3 segments myocardial perfusion defect, 10 of them had normal Hcy, and 7 with hyperhomocysteinemia, in patients with 0.05). Conclusion: Our data may indicate that hyperhomocysteinemia represents an independent risk factor in patients with high possibility of CAD rather than a mark of myocardial ischemia or coronary stenosis

  11. Characteristic findings of exercise ECG test, perfusion SPECT and coronary angiography in patients with exercise induced myocardial stunning

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Byeong Cheol; Seo, Ji Hyoung; Bae, Jin Ho; Jeong, Shin Young; Park, Hun Sik; Lee, Jae Tae; Chae, Shung Chull; Lee, Kyu Bo [School of Medicine, Kyungpook National Univ., Daegu (Korea, Republic of)

    2004-06-01

    Transient wall motion abnormality and contractile dysfunction of the left ventricle (LV) can be observed in patients with coronary artery disease due to post-stress myocardial stunning. To understand clinical characteristics of stress induced LV dysfunction, we have compared the findings of exercise stress test, myocardial perfusion SPECT and coronary angiography between subjects with and without post-stress LV dysfunction. Among subjects who underwent exercise stress test, myocardial perfusion SPECT and coronary angiography within a month of interval, we enrolled 36 patients with post-stress LV ejection fraction (LVEF) was {>=}5% lower than rest (stunning group) and 16 patients with difference of post-stress and rest LVEF was lesser than 1% (non-stunning group) for this study. Treadmill exercise stress gated myocardial perfusion SPECT was performed with dual head SPECT camera using 740 MBq Tc-99m MIBI and coronary angiography was also performed by conventional Judkins method. Stunning group had a significantly higher incidence of hypercholesterolemia than non-stunning group(45.5 vs 7.1%, p=0.01). Stunning group also had higher incidence of diabetes mellitus and lower incidence of hypertension, but these were not statistically significant. Stunning group had larger and more severe perfusion defect in stress perfusion myocardial SPECT than non-stunning group(extent 18.2 vs 9.2%, p=0.029; severity 13.5 vs 6.9, p=0.040). Stunning group also had higher degree of reversibility of perfusion defect, higher incidence of positive exercise stress test and higher incidence of having severe stenosis(80{approx}99%) in coronary angiography than non-stunning group, but these were not statistically significant. In stunning group, all of 4 patients without perfusion defect had significant coronary artery stenosis and had received revascularization treatment. Patients with post-stress LV dysfunction had larger and more severe perfusion defect and severe coronary artery stenosis than

  12. Clinical evaluation of 99Tcm-MIBI myocardial perfusion imaging for the detection of coronary artery disease in patients with metabolic syndrome

    International Nuclear Information System (INIS)

    Tian Yueqin; Wei Hongxing; Guo Xinhua; Guo Feng; He Zuoxiang

    2008-01-01

    Objective: Metabolic syndrome is a combination of medical disorders that consist of a collection of independent factors at risk of developing coronary artery disease. The purpose of this study was to evaluate the value of 99 Tc m -methoxyisobutylisonitrile (MIBI) myocardial perfusion imaging for the diagnosis of coronary artery disease in patients with metabolic syndrome. Methods: A total of 251 patients [mean age (59 ± 10) years, 179 men, 72 women] were included in this study. All patients underwent exercise and rest 99 Tc m -MIBI myocardial perfusion imaging and coronary angiography. Results: Of the 163 patients with significant coronary artery stenosis, 116 showed abnormal 99 Tc m -MIBI myocardial perfusion imaging; and among the 88 patients with normal coronary angiography, 82 showed normal myocardial perfusion imaging. The sensitivity, specificity and accuracy of 99 Tc m -MIBI myocardial perfusion imaging for coronary artery disease detection were 71% (116/163), 93% (82/88) and 79% (198/251), respectively. The positive and negative predictive values were 95% (116/122) and 64% (82/129), respectively. Conclusion: 99 Tc m -MIBI myocardial perfusion imaging has important clinical value for detecting coronary artery disease in patients with metabolic syndrome. (authors)

  13. Can preoperative myocardial perfusion scintigraphy predict changes in left ventricular perfusion and function after coronary artery bypass graft surgery?

    DEFF Research Database (Denmark)

    Eckardt, Rozy; Kjeldsen, Bo Juel; Johansen, Allan

    2012-01-01

    OBJECTIVESWe wanted to evaluate whether preoperative myocardial perfusion scintigraphy (MPS) could predict changes in cardiac symptoms and postoperative myocardial perfusion and left ventricular function after coronary artery bypass grafting (CABG).METHODSNinety-two patients with stable angina...... in 26%. Left ventricular ejection fraction (LVEF), which was normal before operation in 45%, improved in 40% of all patients. The increase in LVEF was not related to the preoperative pattern of perfusion defects. Of 30 patients with normalized perfusion after CABG, 29 (97%) had reversible defects...... that reversible or partly reversible perfusion defects at a preoperative MPS have a high chance of normalized myocardial perfusion assessed by MPS 6 months after operation. Normal perfusion is obtained almost exclusively in territories with reversible ischaemia. Symptoms improved in nearly all patients and LVEF...

  14. Combined evaluation of regional coronary artery calcium and myocardial perfusion by {sup 82}Rb PET/CT in the identification of obstructive coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Zampella, Emilia; Assante, Roberta; Nappi, Carmela; Mainolfi, Ciro Gabriele; Green, Roberta; Cantoni, Valeria; Klain, Michele; Cuocolo, Alberto [University Federico II, Department of Advanced Biomedical Sciences, Naples (Italy); Acampa, Wanda [University Federico II, Department of Advanced Biomedical Sciences, Naples (Italy); National Council of Research, Institute of Biostructure and Bioimaging, Naples (Italy); Gaudieri, Valeria; Panico, Mariarosaria [National Council of Research, Institute of Biostructure and Bioimaging, Naples (Italy); Petretta, Mario [University Federico II, Department of Translational Medical Sciences, Naples (Italy); Slomka, Piotr J. [Cedars-Sinai Medical Center, Department of Medicine, Los Angeles, CA (United States); UCLA, David Geffen School of Medicine, Los Angeles, CA (United States)

    2018-04-15

    Cardiac imaging with PET/CT allows measurement of coronary artery calcium (CAC), myocardial perfusion and coronary vascular function. We investigated whether the combined assessment of regional CAC score, ischemic total perfusion deficit (ITPD) and quantitative coronary vascular function would further improve the diagnostic accuracy of PET/CT in predicting obstructive coronary artery disease (CAD). We analyzed 113 patients with suspected CAD referred to {sup 82}Rb PET/CT myocardial perfusion imaging with available coronary angiographic data. Obstructive CAD was defined as ≥75% stenosis. The receiver operating characteristic area under curve (AUC) was applied to evaluate the ability of CAC score, ITPD, hyperemic myocardial blood flow (MBF) and coronary flow reserve (CFR) to identify CAD. Vessels with obstructive CAD (71 vessels) had higher ITPD (4.6 ± 6.2 vs. 0.6 ± 1.3) and lower hyperemic MBF (1.01 ± 0.5 vs. 1.75 ± 0.6 ml/min/g) and CFR (1.56 ± 0.6 vs. 2.38 ± 0.7; all p < 0.001) than those without. In prediction of per-vessel CAD, the AUCs for the models including CAC/ITPD/hyperemic MBF (0.869) and CAC/ITPD/CFR (0.875) were higher (both p < 0.01) than for the model including CAC/ITPD (0.790). Compared with CAC/ITPD, continuous net reclassification improvement was 0.69 (95% bootstrap confidence interval, CI, 0.365-1.088) for the CAC/ITPD/hyperemic MBF model and 0.99 (95% bootstrap CI 0.64-1.26) for the CAC/ITPD/CFR model. Hyperemic MBF and CFR provide incremental information about the presence of CAD over CAC score and perfusion imaging parameters. The combined use of CAC, myocardial perfusion imaging and quantitative coronary vascular function in may help predict more accurately the presence of obstructive CAD. (orig.)

  15. Pomegranate Extract Enhances Endothelium-Dependent Coronary Relaxation in Isolated Perfused Hearts from Spontaneously Hypertensive Ovariectomized Rats

    Science.gov (United States)

    Delgado, Nathalie T. B.; Rouver, Wender do N.; Freitas-Lima, Leandro C.; de Paula, Tiago D.-C.; Duarte, Andressa; Silva, Josiane F.; Lemos, Virgínia S.; Santos, Alexandre M. C.; Mauad, Helder; Santos, Roger L.; Moysés, Margareth R.

    2017-01-01

    Decline in estrogen levels promotes endothelial dysfunction and, consequently, the most prevalent cardiovascular diseases in menopausal women. The use of natural therapies such as pomegranate can change these results. Pomegranate [Punica granatum L. (Punicaceae)] is widely used as a phytotherapeutic agent worldwide, including in Brazil. We hypothesized that treatment with pomegranate hydroalcoholic extract (PHE) would improve coronary vascular reactivity and cardiovascular parameters. At the beginning of treatment, spontaneously hypertensive female rats were divided into Sham and ovariectomized (OVX) groups, which received pomegranate extract (PHE) (250 mg/kg) or filtered water (V) for 30 days by gavage. Systolic blood pressure was measured by tail plethysmography. After euthanasia, the heart was removed and coronary vascular reactivity was assessed by Langendorff retrograde perfusion technique. A dose-response curve for bradykinin was performed, followed by L-NAME inhibition. The protein expression of p-eNOS Ser1177, p-eNOS Thr495, total eNOS, p-AKT Ser473, total AKT, SOD-2, and catalase was quantified by Western blotting. The detection of coronary superoxide was performed using the protocol of dihydroethidium (DHE) staining Plasma nitrite measurement was analyzed by Griess method. Systolic blood pressure increased in both Sham-V and OVX-V groups, whereas it was reduced after treatment in Sham-PHE and OVX-PHE groups. The baseline coronary perfusion pressure was reduced in the Sham-PHE group. The relaxation was significantly higher in the treated group, and L-NAME attenuated the relaxation in all groups. The treatment has not changed p-eNOS (Ser1177), total eNOS, p-AKT (Ser473) and total AKT in any groups. However, in Sham and OVX group the treatment reduced the p-eNOS (Thr495) and SOD-2. The ovariectomy promoted an increasing in the superoxide anion levels and the treatment was able to prevent this elevation and reducing oxidative stress. Moreover, the treatment

  16. Exercise-induced thallium-201 myocardial perfusion defects in angina pectoris without significant coronary artery stenosis

    International Nuclear Information System (INIS)

    Nakazato, Masayasu; Maruoka, Yuji; Sunagawa, Osahiko; Kinjo, Kunihiko; Tomori, Masayuki; Fukiyama, Koshiro

    1990-01-01

    We performed exercise thallium-201 myocardial scintigraphy in 32 patients with angina pectoris to study the incidence of perfusion defects, who had no significant organic stenosis on coronary angiography. None of them had myocardial infarction or cardiomyopathy. Thallium-201 myocardial scintigraphy and 12-lead ECG recording were performed during supine bicycle ergometer exercise. Perfusion defects in thallium-201 scintigrams in SPECT images were assessed during visual analysis by two observers. In the coronary angiograms obtained during intravenous infusion of nitroglycerin, the luminal diameter of 75% stenosis or less in the AHA classification was regarded as an insignificant organic stenosis. Myocardial perfusion defects in the thallium-201 scintigrams were detected in eight (25%) of the 32 patients. Six of these eight patients had variant angina documented during spontaneous attacks with ST elevations in standard 12-lead ECGs. Perfusion defects were demonstrated at the inferior or infero-posterior regions in six patients, one of whom had concomitant anteroseptal defect. The defects were not always accompanied by chest pain. All but one patient demonstrating inferior or inferoposterior defects showed ST depression in leads II, III and aV F on their ECGs, corresponding to inferior wall ischemia. The exception was a case with right bundle branch block. Thus, 25% of the patients with angina pectoris, who had no evidence of significant organic stenosis on their coronary angiograms, exhibited exercise-induced perfusion defects in their thallium-201 scintigrams. Coronary spasms might have caused myocardial ischemia in these patients. (author)

  17. Influence of ocular perfusion pressure fluctuation on glaucoma

    Directory of Open Access Journals (Sweden)

    Min-Zi Ren

    2015-12-01

    Full Text Available AIM:To investigate the influence of ocular perfusion pressure fluctuation on glaucoma. METHODS:Forty patients with primary open angle glaucoma from January 2013 to June 2015 in our hospital were used as observation group and 40 families were used as control group. Circadian fluctuation of intraocular pressure, blood pressure and ocular perfusion pressure in 24h were determined to obtain systolic ocular perfusion pressure(SOPP, diastolic ocular perfusion pressure(DOPPand mean ocular perfusion pressure(MOPP. Pearson linear correlation was used to analyze the correlation of circadian MOPP fluctuation with cup-disc ratio, mean defect(MDand the picture standard deviation(PSD. RESULTS:The fluctuation of MOPP, SOPP and DOPP of observation group were significantly higher than those of control group(Pr=-0.389, 95%CI:-0.612~-0.082; P=0.011, was positively correlated with PSD(r=0.512, 95%CI:0.139 ~0.782; P=0.008; no correlation was found between it and the vertical cup-disc ratio(r=0.115, 95%CI:0.056~0.369; P=0.355. CONCLUSION:Ocular perfusion pressure fluctuations in patients with primary open angle glaucoma may reflect the severity of the disease and may make the situation aggravating. Therefore through perfusion pressure monitor in 24h may help us understand the ocular blood flow and the development of primary open-angle glaucoma.

  18. Coronary perfusion pressure and compression quality in maternal cardiopulmonary resuscitation in supine and left-lateral tilt positions: A prospective, crossover study using mannequins and swine models.

    Science.gov (United States)

    Dohi, Satoshi; Ichizuka, Kiyotake; Matsuoka, Ryu; Seo, Kohei; Nagatsuka, Masaaki; Sekizawa, Akihiko

    2017-09-01

    The risk of maternal and fetal mortality is high if cardiopulmonary arrest occurs during pregnancy. To assess the best position for maternal cardiopulmonary resuscitation (CPR), a prospective randomized crossover study was undertaken, involving basic life support mannequin-based simulation (BLS-MS) and a swine model of pulseless electrical activity (an unstable cardiac state) incorporating a fetal mannequin (PEA-FM). The BLS-MS (performed by certified rescuers) served to evaluate the quality of chest compressions in 30° left lateral tilt (LLT) and supine positions. Based on a 5-point scale, each rescuer subjectively graded their experience. The PEA-FM model was used to compare coronary perfusion pressure readings during CPR in supine, supine with left uterine displacement, 30° LLT, and 30° right lateral tilt positions. Compression rate and correctness of hand position, compression depth, and recoil were measures of compression quality (BLS-MS). Compared with LLT position, supine position enabled correct hand position (rate: 0.99 vs 0.88; p<0.05) and compression depth (rate: 0.76 vs 0.36; p<0.001) significantly more often. Moreover, BLS-MS rescuers found chest compressions significantly easier to perform with the mannequin in supine (vs LLT) position (difficulty score: 1.75 vs 3.95; p<0.001). In the PEA-FM study arm, supine position with left uterine displacement and right lateral tilt positions had the highest and lowest recorded coronary perfusion pressure readings, respectively. Supine position with left uterine displacement is optimal for maternal CPR. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  19. [Synchronized anterograde perfusion during percutaneous transluminal coronary angioplasty: preliminary clinical study].

    Science.gov (United States)

    Farcot, J C; Berland, J; Derumeaux, G; Letac, B; Bourdarias, J P

    1995-03-01

    A new circulatory system, "physiologic anteroperfusion system", has been developed and tested in 6 patients with significant proximal coronary artery stenosis. Prolonged and safe balloon inflation was possible without any ischemic signs. The system consists of an electronic cardiac synchroperfusor which, by activating a pulsatile unit, permits increased diastolic anteroperfusion of autologous blood under physiologic pressure through low-profile standard angioplasty catheters. This study reports the results obtained in 6 patients during proximal prolonged percutaneous transluminal coronary angioplasty. Four men and two women suffering from severe exertional angina pectoris, with normal resting left ventricular function, no collaterals and excellent apical two-dimensional four-chamber echocardiographic views were studied. After a 90 +/- 10 seconds of control occlusion under continuous monitoring of hemodynamics, electrocardiograms (3 to 4 leads), two-dimensional echo and chest pain grading, a second balloon inflation protected by the physiologic anteroperfusion system at a flow rate of 44 +/- 12 ml/min was performed for fifteen minutes. The ischemic signs present in the myocardium depending on the occluded artery were totally abolished during prolonged inflation protected by physiologic anteroperfusion system. All the patients were successfully dilated and were discharged from hospital the following morning without cardiac enzyme elevation or signs of central or peripheral hemolysis. Conclusion, in 6 patients with severe proximal coronary artery stenosis, safe prolonged proximal angioplasty without signs of ischemia was performed using a new simple physiologic anteroperfusion system, which allows active diastolic flow-pressure controlled autologous arterial blood perfusion, through standard low profile catheters.

  20. First-pass perfusion disturbance of coronary artery stenosis: an experimental study using MR imaging with Gd-DTPA enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Kyung Il; Lee, Young Ju [Ajou Univ. College of Medicine, Seoul (Korea, Republic of); Lim, Tae Hwan [Ulsan Univ. College of Medicine, Ulsan (Korea, Republic of)] [and others

    1997-11-01

    In order to determine the value of first-pass MR imaging in the diagnosis of myocardial ischemia, first-pass perfusion abnormality of coronary artery stenosis was observed in MRI after gadopentate dimeglumine(GD-DTPA) enhancement. The left anterior descending(LAD) coronary arteries of six dogs were subjected to approximately 70% stenosis confirmed by coronary angiography. Half an hour after adenosine and {sup 99m}Tc-sestamibi infusion, Gd-DTPA(0.2mmol/kg) and methylene blue were administered and termination was induced with potassium chloride. SE T1-weighted and single-photon emission computed tomography(SPECT) images were subsequently obtained and the findings of perfusion defect compared with specimen stain. Three dimensionally reconstructed MR images were used to measure signal intensity(SI) of normal myocardium and perfusion defect from their sectional and total volume. Five of six dogs with LAD artey stenosis ranging from 66% to 73% displayed perfusion defect on MRI, SPECT, and specimen stain, but the remaining dog with stenosis of 58% showed no such defect. MRI showed the perfusion defect as distinct low SI, enabling the measurement of percentage perfusion defect(24.4{+-}5.4%), which increased inferiorly. SI of normal myocardium and perfusion defect decreased inferiorly; their difference indicated stenosis-induced perfusion loss according to section location. Volumetric SI of normal myocardium and perfusion defect were 3.42{+-}0.52 and 2.16{+-}0.45, respectively(p<0.05). Gd-DTPA enhanced MRI displayed first-pass perfusion abnormality of coronary artery stenosis as perfusion defect with distinct low SI; this enabled the measurement of its volume and SI changes according to section location, and thus indicated the value of first-pass MR imaging in the diagnosis of myocardial ischemia.

  1. First-pass perfusion disturbance of coronary artery stenosis: an experimental study using MR imaging with Gd-DTPA enhancement

    International Nuclear Information System (INIS)

    Chung, Kyung Il; Lee, Young Ju; Lim, Tae Hwan

    1997-01-01

    In order to determine the value of first-pass MR imaging in the diagnosis of myocardial ischemia, first-pass perfusion abnormality of coronary artery stenosis was observed in MRI after gadopentate dimeglumine(GD-DTPA) enhancement. The left anterior descending(LAD) coronary arteries of six dogs were subjected to approximately 70% stenosis confirmed by coronary angiography. Half an hour after adenosine and 99m Tc-sestamibi infusion, Gd-DTPA(0.2mmol/kg) and methylene blue were administered and termination was induced with potassium chloride. SE T1-weighted and single-photon emission computed tomography(SPECT) images were subsequently obtained and the findings of perfusion defect compared with specimen stain. Three dimensionally reconstructed MR images were used to measure signal intensity(SI) of normal myocardium and perfusion defect from their sectional and total volume. Five of six dogs with LAD artey stenosis ranging from 66% to 73% displayed perfusion defect on MRI, SPECT, and specimen stain, but the remaining dog with stenosis of 58% showed no such defect. MRI showed the perfusion defect as distinct low SI, enabling the measurement of percentage perfusion defect(24.4±5.4%), which increased inferiorly. SI of normal myocardium and perfusion defect decreased inferiorly; their difference indicated stenosis-induced perfusion loss according to section location. Volumetric SI of normal myocardium and perfusion defect were 3.42±0.52 and 2.16±0.45, respectively(p<0.05). Gd-DTPA enhanced MRI displayed first-pass perfusion abnormality of coronary artery stenosis as perfusion defect with distinct low SI; this enabled the measurement of its volume and SI changes according to section location, and thus indicated the value of first-pass MR imaging in the diagnosis of myocardial ischemia

  2. Comparison of stress-rest and rest-stress one day myocardial perfusion scintigraphies in detecting coronary artery diseases

    International Nuclear Information System (INIS)

    Bom, Hee Seung; Min, Jung Jun; Song, Ho Cheon; Kim, Ji Yeul

    1997-01-01

    It has been shown that both rest and stress myocardial perfusion imaging with technetium agents can be performed on the same day using two different doses injected within few hours. The purpose of this study was to compare the two protocols (stress-rest and rest-stress) in detecting coronary artery diseases. One hundred and sixty patients (101 males, 59 females, mean age 57±9 years) and 120 patients (79 males, 41 females, mean age 59±10 years) underwent stress-rest myocardial perfusion SPECT and rest-stress myocardial perfusion SPECT, respectively. All of them underwent both myocardial perfusion SPECT and coronary angiography within 1 month. A coronary stenosis was considered significant when it compromised the luminal diameter by ≥50%. The chi square test was used to compare differences in sensitivity, specificity and accuracy between the two groups. The overall sensitivity, specificity and accuracy of stress-rest protocol were 99%, 35% and 68%, respectively. Those of rest-stress protocol were 96%, 47% and 78%, respectively. There was no difference between the two protocols in identifying individual diseased coronary artery branches. Therefore, one day stress-rest and rest-stress myocardial SPECT using 99m Tc agents were comparable and were very sensitive tests in detecting coronary artery diseases

  3. Incremental value of myocardial perfusion over coronary angiography by spectral computed tomography in patients with intermediate to high likelihood of coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Carrascosa, Patricia M., E-mail: investigacion@diagnosticomaipu.com.ar; Deviggiano, Alejandro; Capunay, Carlos; Campisi, Roxana; López Munain, Marina de; Vallejos, Javier; Tajer, Carlos; Rodriguez-Granillo, Gaston A.

    2015-04-15

    Highlights: •We evaluated myocardial perfusion by dual energy computed tomography (DECT). •We included patients with intermediate to high likelihood of coronary artery disease. •Stress myocardial perfusion by DECT had a reliable accuracy for the detection of ischemia. •Stress myocardial perfusion with DECT showed an incremental value over anatomical evaluation. •DECT imaging was associated to a significant reduction in radiation dose compared to SPECT. -- Abstract: Purpose: We sought to explore the diagnostic performance of dual energy computed tomography (DECT) for the evaluation of myocardial perfusion in patients with intermediate to high likelihood of coronary artery disease (CAD). Materials and methods: Consecutive patients with known or suspected CAD referred for myocardial perfusion imaging by single-photon emission computed tomography (SPECT) constituted the study population and were scanned using a DECT scanner equipped with gemstone detectors for spectral imaging, and a SPECT. The same pharmacological stress was used for both scans. Results: Twenty-five patients were prospectively included in the study protocol. The mean age was 63.4 ± 10.6 years. The total mean effective radiation dose was 7.5 ± 1.2 mSv with DECT and 8.2 ± 1.7 mSv with SPECT (p = 0.007). A total of 425 left ventricular segments were evaluated by DECT, showing a reliable accuracy for the detection of reversible perfusion defects [area under ROC curve (AUC) 0.84 (0.80–0.87)]. Furthermore, adding stress myocardial perfusion provided a significant incremental value over anatomical evaluation alone by computed tomography coronary angiography [AUC 0.70 (0.65–0.74), p = 0.003]. Conclusions: In this pilot investigation, stress myocardial perfusion by DECT demonstrated a significant incremental value over anatomical evaluation alone by CTCA for the detection of reversible perfusion defects.

  4. Prevalence and pattern of abnormal myocardial perfusion in patients with isolated coronary artery ectasia: study by 99mTc-sestamibi radionuclide scintigraphy.

    Science.gov (United States)

    Ismail, Ahmed M; Rayan, Mona; Adel, Amr; Demerdash, Salah; Atef, Mohamed; Abdallah, Mohamed; Nammas, Wail

    2014-02-01

    We explored the prevalence and pattern of abnormal myocardial perfusion in patients with isolated coronary artery ectasia (CAE), as demonstrated by (99m)Tc-sestamibi scintigraphy. Prospectively, we enrolled 35 patients with angiographically documented CAE and no significant coronary obstruction, who underwent elective coronary angiography. Patients underwent Stress-rest (99m)Tc-sestamibi scintigraphy within 4 days of coronary angiography. They were divided into 2 groups: group I: with normal perfusion scan; and group II: with reversible perfusion defects. The mean age was 49.6 ± 6.9 years; 34 (97.1 %) were males. Seventy-nine (75.2 %) arteries were affected by CAE. Among 79 arteries affected by CAE, affection was diffuse in 37 (46.8 %). Thirteen (37.1 %) patients had normal perfusion scan (group I), whereas 22 (62.9 %) had reversible perfusion defects (group II). Among 22 patients with reversible perfusion defects, 20 (90.9 %) had mild and 2 (9.1 %) had moderate ischemia. Among 49 myocardial segments with reversible perfusion defects, 22 (44.9 %) were basal, 18 (36.7 %) mid-, and 9 (18.4 %) apical segments. Diffuse CAE was significantly more prevalent in group II versus group I, in all 3 major coronary arteries (p < 0.05 for all). In patients with isolated CAE who underwent elective coronary angiography, reversible perfusion defects demonstrated by (99m)Tc-sestamibi scintigraphy were rather prevalent, mostly mild, more likely to affect the basal and mid-segments of the myocardium, and more frequently associated with diffuse ectasia.

  5. Reversible defects on myocardial perfusion imaging early after coronary stent implantation: a predictor of late restenosis

    International Nuclear Information System (INIS)

    Kim, D. E.; Park, S. A.; Kim, C. K.; Chang, J. A.; Jeong, J. W.; Oh, S. G.; Lee, C.

    2007-01-01

    It appears logical that myocardial perfusion should be fixed and not reversible, in the territory supplied by a dilated coronary artery. However, several studies have demonstrated reversible perfusion in the territory supplied by a coronary artery with an optimally implanted stent. The main objective of this study was to evaluate the incidence of reversible defects detected by M-SPECT early after optimal PTCA with stent implantation. Its second objective was to determine the predictive value of detecting reversible defects after stent implantation for late restenosis. Sixty-six patients that underwent M-SPECT within 24 hours of successful PTCA with stent implantation were included. All patients were followed up clinically and angiographically. The incidence of reversible perfusion defects on M-SPECT and the rate of late restenosis in target coronary arteries were evaluated retrospectively. Reversible perfusion defects on M-SPECT were observed in 26% of the patients and in 36% of lesions following successful PTCA with stent implantation. The incidence of late restenosis was significantly higher in patients and lesions with reversible perfusion defects (47% vs. 18%). According to binary logistic regression analysis, the presence of a reversible perfusion defects was the only independent predictor of late restenosis. This study shows that the predictive value of reversible perfusion defects on M-SPECT early after stent implantation with respect to the incidence of late restenosis was 47% in patients with a reversible defect, and 18% in those without it

  6. Characteristics of myocardial perfusion imaging and coronary artery angiography in patients of NIDDM complicated with AMI

    International Nuclear Information System (INIS)

    Zhao Peiqin; Zhao Jinhua; Qin Mingzhao; Dai HaoJie; Zhang Runwu; Xiao Fen

    2001-01-01

    Objective: To investigate the characteristic changes of myocardial perfusion imaging and coronary artery angiography in patients of acute myocardial infarction (AMI) with underlined type 2 diabetes mellitus. Methods: 25 type 2 diabetes mellitus patients were enrolled for having clinical manifestation of AMI. Ten inpatients with AMI of simple coronary heart disease origin were served as controls. All subjects underwent both myocardial perfusion imagings (resting and nitroglycerine invention) and coronary artery angiography. Results: Compared to controls (40%), type 2 diabetes mellitus + AMI group had higher rate of multivessel disease (60%). For type 2 diabetes mellitus + AMI patients, 129/400 segments (32.25%) showed fixed defect, 25/160 segments (15.62%) in controls. Conclusions: For type 2 diabetes mellitus + AMI group, myocardial perfusion defects are widely distributed and multivessel or severe stenosis is more often presented. Good correlation exists between abnormal segments and angiographic lesions in both the number of segments involved and the severity of the lesions. Radionuclide myocardial perfusion is therefore considered a useful screening test not inferior to angiography, especially for those who are not tolerant enough to undergoing angiography

  7. Diagnostic value of transmural perfusion ratio derived from dynamic CT-based myocardial perfusion imaging for the detection of haemodynamically relevant coronary artery stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Coenen, Adriaan; Lubbers, Marisa M.; Dedic, Admir; Chelu, Raluca G.; Geuns, Robert-Jan M. van; Nieman, Koen [Erasmus University Medical Center, Department of Radiology, Rotterdam (Netherlands); Erasmus University Medical Center, Department of Cardiology, Rotterdam (Netherlands); Kurata, Akira; Kono, Atsushi; Dijkshoorn, Marcel L. [Erasmus University Medical Center, Department of Radiology, Rotterdam (Netherlands); Rossi, Alexia [Erasmus University Medical Center, Department of Radiology, Rotterdam (Netherlands); Barts Health NHS Trust, NIHR Cardiovascular Biomedical Research Unit at Barts, William Harvey Research Institute, Barts and The London School of Medicine and Dentistry, Queen Mary University of London and Department of Cardiology, London (United Kingdom)

    2017-06-15

    To investigate the additional value of transmural perfusion ratio (TPR) in dynamic CT myocardial perfusion imaging for detection of haemodynamically significant coronary artery disease compared with fractional flow reserve (FFR). Subjects with suspected or known coronary artery disease were prospectively included and underwent a CT-MPI examination. From the CT-MPI time-point data absolute myocardial blood flow (MBF) values were temporally resolved using a hybrid deconvolution model. An absolute MBF value was measured in the suspected perfusion defect. TPR was defined as the ratio between the subendocardial and subepicardial MBF. TPR and MBF results were compared with invasive FFR using a threshold of 0.80. Forty-three patients and 94 territories were analysed. The area under the receiver operator curve was larger for MBF (0.78) compared with TPR (0.65, P = 0.026). No significant differences were found in diagnostic classification between MBF and TPR with a territory-based accuracy of 77 % (67-86 %) for MBF compared with 70 % (60-81 %) for TPR. Combined MBF and TPR classification did not improve the diagnostic classification. Dynamic CT-MPI-based transmural perfusion ratio predicts haemodynamically significant coronary artery disease. However, diagnostic performance of dynamic CT-MPI-derived TPR is inferior to quantified MBF and has limited incremental value. (orig.)

  8. The progress of research on myocardial perfusion imaging in diabetic coronary disease

    International Nuclear Information System (INIS)

    Zhao Qian; Li Juan

    2007-01-01

    The morbidity of diabetes mellitus is gradually increasing. It's most important complication is cardiovascular disease. The coronary disease is the main cause of death in patients with diabetes mellitus. The stress myocardial perfusion imaging help diagnose diabetic coronary disease and prognosis judgement and risk assessment. So it can improve the living standard of patients with diabetes mellitus, and decrease the mortality of diabetes mellitus. (authors)

  9. Quantitative angiography of the left anterior descending coronary artery: correlations with pressure gradient and exercise thallium scintigraphy

    International Nuclear Information System (INIS)

    Reiber, J.H.C.; Serruys, P.W.; Slager, C.J.; Erasmus Univ., Rotterdam

    1986-01-01

    In order to evaluate during cardiac catheterization what constitutes a physiologically significant obstruction to blood flow in the human coronary system, computer based quantitative analysis of coronary angiograms was performed in 31 patients with isolated proximal left anterior descending coronary artery disease. The angiographic severity of the stenosis was compared with the transstenotic pressure gradient measured with the dilatation catheter during angioplasty and the results of exercise thallium scintigraphy. A curvilinear relation was found between the pressure gradient across the stenosis (normalized for the mean aortic pressure) and the residual minimal obstruction area (after subtracting the area of the angioplasty catheter). This relation was best fitted by the equation: normalized mean pressure gradient = a + b · log [obstruction area], r = 0.74. The measurements of the percent area stenosis (cut-off 80%) and of the transstenotic pressure gradient (cut-off 0.30) obtained at rest, correctly predicted the occurrence of thallium perfusion defects induced by exercise in 83% of the patients. (Auth.)

  10. Stress Perfusion Coronary Flow Reserve Versus Cardiac Magnetic Resonance for Known or Suspected CAD.

    Science.gov (United States)

    Kato, Shingo; Saito, Naka; Nakachi, Tatsuya; Fukui, Kazuki; Iwasawa, Tae; Taguri, Masataka; Kosuge, Masami; Kimura, Kazuo

    2017-08-15

    Phase-contrast (PC) cine magnetic resonance imaging (MRI) of the coronary sinus is a noninvasive method to quantify coronary flow reserve (CFR). This study sought to compare the prognostic value of CFR by cardiac magnetic resonance (CMR) and stress perfusion CMR to predict major adverse cardiac events (MACE). Participants included 276 patients with known coronary artery disease (CAD) and 400 with suspected CAD. CFR was calculated as myocardial blood flow during adenosine triphosphate infusion divided by myocardial blood flow at rest using PC cine MRI of the coronary sinus. During a median follow-up of 2.3 years, 47 patients (7%) experienced MACE. Impaired CFR (10% ischemia on stress perfusion CMR were significantly associated with MACE in patients with known CAD (hazard ratio [HR]: 5.17 and HR: 5.10, respectively) and suspected CAD (HR: 14.16 and HR: 6.50, respectively). The area under the curve for predicting MACE was 0.773 for CFR and 0.731 for stress perfusion CMR (p = 0.58) for patients with known CAD, and 0.885 for CFR and 0.776 for stress perfusion CMR (p = 0.059) in the group with suspected CAD. In patients with known CAD, sensitivity, specificity, and positive and negative predictive values to predict MACE were 64%, 91%, 38%, and 97%, respectively, for CFR, and 82%, 59%, 15%, and 97%, respectively, for stress perfusion CMR. In the suspected CAD group, these values were 65%, 99%, 80%, and 97%, respectively, for CFR, and 72%, 83%, 22%, and 98%, respectively, for stress perfusion CMR. The predictive values of CFR and stress perfusion CMR for MACE were comparable in patients with known CAD. In patients with suspected CAD, CFR showed higher HRs and areas under the curve than stress perfusion CMR, suggesting that CFR assessment by PC cine MRI might provide better risk stratification for patients with suspected CAD. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  11. Diagnostic performance of combined noninvasive coronary angiography and myocardial perfusion imaging using 320 row detector computed tomography

    DEFF Research Database (Denmark)

    Vavere, Andrea L; Simon, Gregory G; George, Richard T

    2013-01-01

    Multidetector coronary computed tomography angiography (CTA) is a promising modality for widespread clinical application because of its noninvasive nature and high diagnostic accuracy as found in previous studies using 64 to 320 simultaneous detector rows. It is, however, limited in its ability...... to detect myocardial ischemia. In this article, we describe the design of the CORE320 study ("Combined coronary atherosclerosis and myocardial perfusion evaluation using 320 detector row computed tomography"). This prospective, multicenter, multinational study is unique in that it is designed to assess...... the diagnostic performance of combined 320-row CTA and myocardial CT perfusion imaging (CTP) in comparison with the combination of invasive coronary angiography and single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI). The trial is being performed at 16 medical centers located in 8...

  12. The evaluation of dobutamine 99mTc-MIBI myocardial perfusion imaging in the diagnosis of coronary heart disease

    International Nuclear Information System (INIS)

    He Qing; Qu Wanying; Gong Junhui; Zhou Ying

    1996-01-01

    The method and the clinical value of dobutamine stress test as a substitute for exercise test in 99m Tc-MIBI myocardial perfusion imaging was investigated. 40 Patients were intravenously infused with dobutamine through IVAC syringe pumps by incremental doses, and 99m Tc-MIBI was injected at the peak dobutamine heart rate. The myocardial imaging was then performed. The rest myocardial imaging was done after 48 hours. 30 of the 31 patients with coronary heart disease showed reversible perfusion defects in dobutamine 99m Tc-MIBI myocardial perfusion images and 7 of the 9 patients without coronary heart disease showed normal images. The sensitivity of this test was 96.8% and the specificity 77.8%. None of the studies was discontinued due to dobutamine side effect. Dobutamine 99m Tc-MIBI myocardial perfusion imaging is a safe and sensitive method in the diagnosis of coronary heart disease

  13. Prognostic value of myocardial perfusion SPECT imaging in elderly patients without history of coronary artery disease and low prevalence of them

    International Nuclear Information System (INIS)

    Arja, V.J.; Balestrini, V.R.; Sandrin, A.L.; Conci, E.C.; Serra, C.M.; Joekes, S.

    2002-01-01

    Elderly patients without history of coronary artery disease are difficult to characterized because the clinical symptoms are often atypical, occult or absent. On the other hand, these patients frequently cannot achieve adequate level of exercise during stress testing and this limitation can compromise the diagnostic and prognostic ability of the test. Generally the prognostic value of myocardial perfusion SPECT is well established for a general population but not for elderly patients. Aim: This study assessed the prognostic value of Tc99m-sestamibi SPECT in a group of patients older than 65 years with low prevalence of coronary artery disease. Material and Methods: Population: 161 consecutive patients older than 65 years without history of coronary artery disease and low prevalence of them were studied with Tc99m-sestamibi SPECT perfusion imaging. Mean age 71 years old (65-87), male 55%, mean pretest likelihood 11%. Risk factors: diabetes 17%, high blood pressure 74%, high cholesterol 45%, smokers 88%. Stress test: bicycle exercise 39% and dipyridamole 61%. Myocardial perfusion SPECT: semiquantitative analysis to evaluate perfusion defects with a 14-segments model and 4-point scoring system for uptake reduction. Scintigraphic indices: SSS (sum of the stress scores), SRS (sum of the rest scores) and SDS (SSS-SRS). Follow up: cardiac events: hard (acute myocardial infarction and cardiac death) and soft (need for PTCA/CABG and angina). Results: Mean follow up: 508 days. Events rate: hard 0.6% (1 acute myocardial infarction), soft 5.6%. Univariate analysis identified sex (p=0.017) and SDS (p=0.009) as cardiac events predictors. Complete or reduced (independent variables which predicted events) logistic regression analysis correctly predicted the absence of events but did not predict the presence of events. Conclusion: In this elderly population with a low clinical risk where the stress test is a suboptimal method of study for coronary artery disease, semiquantitative

  14. Comparison with myocardial perfusion MRI and myocardial perfusion SPECT in the diagnostic performance of coronary artery disease. A meta-analysis

    International Nuclear Information System (INIS)

    Iwata, Kunihiro; Kubota, Makoto; Ogasawara, Katsuhiko

    2008-01-01

    We compared the diagnostic abilities of stress myocardial perfusion MRI (myocardial perfusion MRI) and myocardial perfusion single photon emission computed tomography (SPECT), using a meta-analysis method. We investigated the diagnostic abilities of MRI and SPECT in similar subject groups in reports written in English or Japanese. The reports to be used for analysis were selected according to a ''screening standard,'' which was established in advance. After consolidating the data from the selected reports, we compared the integrated odds ratio, the point estimation values of sensibility/specificity, and the summary receiver operating characteristic (ROC) curve. For the analysis, six reports were selected (subjects: 153, coronary-artery target sites: 447). Meta-analysis revealed that the diagnostic ability of myocardial perfusion MRI was superior to that of myocardial perfusion SPECT regarding each of the parameters. This is considered to be supportive evidence of the usefulness of myocardial perfusion MRI. (author)

  15. A comparative study of 99Tcm-MIBI exercise myocardial perfusion imaging and the coronary arteriography in the diagnosis of coronary artery disease

    International Nuclear Information System (INIS)

    Huang Xiaohong; Yan Aiping; Li Yuren; Hou Zhenwen; Jiang Ningyi; Lu Xianping

    2003-01-01

    Objective: A comparative evaluation of 99 Tc m -MIBI exercise myocardial perfusion imaging (MPI) and coronary arteriography (CAG) in diagnosis of coronary artery disease. Methods: MPI and CAG were performed on 92 patients with clinical equivocal diagnosis of coronary artery disease. The results were comparatively studied. Results: The sensitivity and specificity of MPI were 83.9% and 69.1%. Both modalities matched in 78.3% cases. Conclusion: MPI offers useful information for the diagnosis of coronary artery disease. And patients with a normal MPI don't need a further coronary angiography

  16. Thallium-201 myocardial perfusion imaging during adenosine-induced coronary vasodilation in patients with ischemic heart disease

    International Nuclear Information System (INIS)

    Takeishi, Yasuchika; Chiba, Junya; Abe, Shinya

    1992-01-01

    Thallium-201 ( 201 Tl) myocardial perfusion imaging during adenosine infusion was performed in consecutive 55 patients with suspected coronary artery disease. Adenosine was infused intravenously at a rate of 0.14 mg/kg/min for 6 minutes and a dose of 111 MBq of 201 Tl was administered in a separate vein at the end of third minutes of infusion. Myocardial SPECT imaging was begun 5 minutes and 3 hours after the end of adenosine infusion. For evaluating the presence of perfusion defects, 2 short axis images at the basal and spical levels and a vertical long axis image at the mid left ventricle were used. The regions with decreased 201 Tl uptake were assessed semi-quantitatively. Adenosine infusion caused a slight reduction in systolic blood pressure and an increase in heart rate. The rate pressure products increased slightly (9314±2377 vs. 10360±2148, p 201 Tl myocardial imaging during adenosine infusion was considered to be safe and useful for evaluating the patients with ischemic heart disease. (author)

  17. Comprehensive Assessment of Coronary Artery Disease by Using First-Pass Analysis Dynamic CT Perfusion: Validation in a Swine Model.

    Science.gov (United States)

    Hubbard, Logan; Lipinski, Jerry; Ziemer, Benjamin; Malkasian, Shant; Sadeghi, Bahman; Javan, Hanna; Groves, Elliott M; Dertli, Brian; Molloi, Sabee

    2018-01-01

    Purpose To retrospectively validate a first-pass analysis (FPA) technique that combines computed tomographic (CT) angiography and dynamic CT perfusion measurement into one low-dose examination. Materials and Methods The study was approved by the animal care committee. The FPA technique was retrospectively validated in six swine (mean weight, 37.3 kg ± 7.5 [standard deviation]) between April 2015 and October 2016. Four to five intermediate-severity stenoses were generated in the left anterior descending artery (LAD), and 20 contrast material-enhanced volume scans were acquired per stenosis. All volume scans were used for maximum slope model (MSM) perfusion measurement, but only two volume scans were used for FPA perfusion measurement. Perfusion measurements in the LAD, left circumflex artery (LCx), right coronary artery, and all three coronary arteries combined were compared with microsphere perfusion measurements by using regression, root-mean-square error, root-mean-square deviation, Lin concordance correlation, and diagnostic outcomes analysis. The CT dose index and size-specific dose estimate per two-volume FPA perfusion measurement were also determined. Results FPA and MSM perfusion measurements (P FPA and P MSM ) in all three coronary arteries combined were related to reference standard microsphere perfusion measurements (P MICRO ), as follows: P FPA_COMBINED = 1.02 P MICRO_COMBINED + 0.11 (r = 0.96) and P MSM_COMBINED = 0.28 P MICRO_COMBINED + 0.23 (r = 0.89). The CT dose index and size-specific dose estimate per two-volume FPA perfusion measurement were 10.8 and 17.8 mGy, respectively. Conclusion The FPA technique was retrospectively validated in a swine model and has the potential to be used for accurate, low-dose vessel-specific morphologic and physiologic assessment of coronary artery disease. © RSNA, 2017.

  18. MYOCARDIAL PERFUSION ASSESSMENT IN FORECASTING EFFECT OF CORONARY ANGIOPLASTY IN PATIENTS WITH ISCHEMIC CHRONIC HEART FAILURE

    Directory of Open Access Journals (Sweden)

    A. B. Mironkov

    2015-01-01

    Full Text Available Aim. To define influence of the left ventricle (LV perfusion defects on the clinical status dynamics after coronary angioplasty in patients with the expressed myocardium dysfunction of ischemic etiology. Materials and methods. Examined 86 patients (81 men and 5 women aged from 46 to 73 years before and in 2–3 days after percutaneous coronary intervention with diagnosis: CAD, CHF with NYHA class III–IV, echocardiography parameters of LV: ejection fraction less than 40%, end-diastolic volume is more than 200 ml. Perfusion defects of myocardium estimated with use of ECG-gated single photon emission computed tomography. Predictors were defined: perfusion defects on LV apex (in score, perfusion defects in the area of LAD, LCx and RCA (%, the LV global perfusion defects (in score and %. Results. In 42% of cases 6-minute walk test increased to 3 times; The NYHA class decreased by 2 classes (group 1. In 28 cases 6-minute walk test increased to 2 times and the NYHA class decreased on 1 class. In 22 patients 6-minute walk test increased less than 50% of reference values and there was no dynamics NYHA class (50 patients of the group 2. Initial extent of LV global perfusion defects in group 1 – 41,2 ± 4,0%, in group 2 – 58,3 ± 2,4% (р = 0,0004. Similar values are received for perfusion indicators in the area of LAD and the LV apex. Prevalence of myocardial perfusion defects at rest reflects prevalence of a cardiosclerosis in a cardiac muscle. Conclusion. Degree of LV myocardial perfusion defects in patients with the expressed heart failure of ischemic etiology is the key indicator influencing clinical efficiency of coronary angioplasty. Critical size for definition of the favorable forecast of revascularization are 60% and more perfusion defects testifying that in a cardiac muscle the focal cardiosclerosis prevails over the functioning myocardium. 

  19. Patterns of disturbed myocardial perfusion in patients with coronary artery disease. Regional myocardial perfusion in angina pectoris

    International Nuclear Information System (INIS)

    Selwyn, A.P.; Forse, G.; Fox, K.; Jonathan, A.; Steiner, R.

    1981-01-01

    Fifty patients who presented with angina pectoris were studied to examine the disturbances of regional myocardial perfusion during stress. Each patient underwent 16-point precordial mapping of the ECG during an exercise test, and coronary and left ventricular angiography. Regional myocardial perfusion was assessed using an atrial pacing test and a short-lived radionuclide, krypton-81m. Eleven patients had negative exercise tests and uniform increases in myocardial activity of krypton-81m of 98 +/- 18.0% during pacing. Ten patients performed 30,000-43,000 J in positive exercise tests. These patients showed abnormal coronary anatomy and increases in myocardial activity of krypton-81m to remote and jeopardized myocardium at the onset of pacing. However, further pacing produced a decrease in activity in the affected segment of 68.0 +/- 9.0% accompanied by ST-segment depression and angina. Twelve patients achieved 26,000-32,000 J in positive exercise tests and had significant coronary artery disease. Atrial pacing produced increased activity of krypton-81m to remote myocardium. The jeopardized segment at first showed no change and then a decrease in regional activity of krypton-81m (89.0 +/- 17%) accompanied by ST-segment depression and chest pain. Seventeen patients achieved only 7000-22,000 J in positive exercise tests. These patients showed abnormal coronary anatomy and developed decreases in regional activity of krypton-81m to the affected segment of myocardium starting at the onset of atrial pacing and decreasing by 88 +/- 0 7.0% below control. We conclude that different patterns of disturbed myocardial distribution of krypton-81m are present during stress-induced ischemia in patients with coronary artery disease. There was a close temporal relationship between these disturbances and ST-segment depression

  20. Quantitative angiography of the left anterior descending coronary artery: correlations with pressure gradient and results of exercise thallium scintigraphy

    International Nuclear Information System (INIS)

    Wijns, W.; Serruys, P.W.; Reiber, J.H.; van den Brand, M.; Simoons, M.L.; Kooijman, C.J.; Balakumaran, K.; Hugenholtz, P.G.

    1985-01-01

    To evaluate, during cardiac catheterization, what constitutes a physiologically significant obstruction to blood flow in the human coronary system, computer-based quantitative analysis of coronary angiograms was performed on the angiograms of 31 patients with isolated disease of the proximal left anterior descending coronary artery. The angiographic severity of stenosis was compared with the transstenotic pressure gradient measured with the dilation catheter during angioplasty and with the results of exercise thallium scintigraphy. A curvilinear relationship was found between the pressure gradient across the stenosis (normalized for the mean aortic pressure) and the residual minimal area of obstruction (after subtracting the area of the angioplasty catheter). This relationship was best fitted by the equation: normalized mean pressure gradient . a + b . log [obstruction area], r . .74. The measurements of the percent area of stenosis (cutoff 80%) and of the transstenotic pressure gradient (cutoff 0.30) obtained at rest correctly predicted the occurrence of thallium perfusion defects induced by exercise in 83% of the patients

  1. Qualitative evaluation of coronary flow during anesthetic induction using thallium-201 perfusion scans

    Energy Technology Data Exchange (ETDEWEB)

    Kleinman, B.; Henkin, R.E.; Glisson, S.N.; el-Etr, A.A.; Bakhos, M.; Sullivan, H.J.; Montoya, A.; Pifarre, R.

    1986-02-01

    Qualitative distribution of coronary flow using thallium-201 perfusion scans immediately postintubation was studied in 22 patients scheduled for elective coronary artery bypass surgery. Ten patients received a thiopental (4 mg/kg) and halothane induction. Twelve patients received a fentanyl (100 micrograms/kg) induction. Baseline thallium-201 perfusion scans were performed 24 h prior to surgery. These scans were compared with the scans performed postintubation. A thallium-positive scan was accepted as evidence of relative hypoperfusion. Baseline hemodynamic and ECG data were obtained prior to induction of anesthesia. These data were compared with the data obtained postintubation. Ten patients developed postintubation thallium-perfusion scan defects (thallium-positive scan), even though there was no statistical difference between their baseline hemodynamics and hemodynamics at the time of intubation. There was no difference in the incidence of thallium-positive scans between those patients anesthetized by fentanyl and those patients anesthetized with thiopental-halothane. The authors conclude that relative hypoperfusion, and possibly ischemia, occurred in 45% of patients studied, despite stable hemodynamics, and that the incidence of these events was the same with two different anesthetic techniques.

  2. Qualitative evaluation of coronary flow during anesthetic induction using thallium-201 perfusion scans

    International Nuclear Information System (INIS)

    Kleinman, B.; Henkin, R.E.; Glisson, S.N.; el-Etr, A.A.; Bakhos, M.; Sullivan, H.J.; Montoya, A.; Pifarre, R.

    1986-01-01

    Qualitative distribution of coronary flow using thallium-201 perfusion scans immediately postintubation was studied in 22 patients scheduled for elective coronary artery bypass surgery. Ten patients received a thiopental (4 mg/kg) and halothane induction. Twelve patients received a fentanyl (100 micrograms/kg) induction. Baseline thallium-201 perfusion scans were performed 24 h prior to surgery. These scans were compared with the scans performed postintubation. A thallium-positive scan was accepted as evidence of relative hypoperfusion. Baseline hemodynamic and ECG data were obtained prior to induction of anesthesia. These data were compared with the data obtained postintubation. Ten patients developed postintubation thallium-perfusion scan defects (thallium-positive scan), even though there was no statistical difference between their baseline hemodynamics and hemodynamics at the time of intubation. There was no difference in the incidence of thallium-positive scans between those patients anesthetized by fentanyl and those patients anesthetized with thiopental-halothane. The authors conclude that relative hypoperfusion, and possibly ischemia, occurred in 45% of patients studied, despite stable hemodynamics, and that the incidence of these events was the same with two different anesthetic techniques

  3. Improved left ventricular function and perfusion at rest after successful transluminal coronary angioplasty

    International Nuclear Information System (INIS)

    Klepzig, H.; Kaltenbach, M.; Standke, R.; Maul, F.D.; Hoer, G.

    1991-01-01

    The purpose of this study was to evaluate left ventricular function and perfusion at rest before and after percutaneous transluminal coronary angioplasty. In consecutive 69 patients in whom coronary stenoses were dilated, the radionuclide left ventricular ejection fraction at rest increased significantly. In 26 of these patients, the ejection fraction increased by at least 4%. In these patients, exercise-induced ischemic ST depression had been more pronounced than in the others. 36 other patients underwent 201 Tl myocardial scintigraphy before and after angioplasty. Twelve patients in whom pre-PTCA images had revealed regions with irreversible 201 Tl uptake defects, showed normal 201 Tl distribution patterns on post-PTCA scintigrams. Post-exercise 201 Tl uptake (representing myocardial perfusion and metabolic activity) during pre-PTCA exercise stress tests was significantly lower in these cases. It is concluded that PTCA can improve left ventricular function and perfusion at rest. This improvement is most obvious in patients with pronounced exercise-induced myocardial ischemia as diagnosed by typical ST segment depression and reduced thallium uptake. (orig.) [de

  4. Coronary grafts flow and cardiac pacing modalities: how to improve perioperative myocardial perfusion.

    LENUS (Irish Health Repository)

    D'Ancona, Giuseppe

    2012-02-03

    OBJECTIVE: Aim of this study was to investigate modifications of coronary grafts flow during different pacing modalities after CABG. MATERIALS AND METHODS: Two separate prospective studies were conducted in patients undergoing CABG and requiring intraoperative epicardial pacing. In a first study (22 patients) coronary grafts flows were measured during dual chamber pacing (DDD) and during ventricular pacing (VVI). In a second study (10 patients) flows were measured during DDD pacing at different atrio-ventricular (A-V) delay periods. A-V delay was adjusted in 25 ms increments from 25 to 250 ms and flow measurements were performed for each A-V delay increment. A transit time flowmeter was used for the measurements. RESULTS: An average of 3.4 grafts\\/patient were performed. In the first study, average coronary graft flow was 47.4+\\/-20.8 ml\\/min during DDD pacing and 41.8+\\/-18.2 ml\\/min during VVI pacing (P = 0.0004). Furthermore average systolic pressure was 94.3+\\/-10.1 mmHg during DDD pacing and 89.6+\\/-12.2 mmHg during VVV pacing (P = 0.0007). No significant differences in diastolic pressure were recorded during the two different pacing modalities. In the second study, maximal flows were achieved during DDD pacing with an A-V delay of 175 ms (54+\\/-9.6 ml\\/min) and minimal flows were detected at 25 ms A-V delay (38.1+\\/-4.7 ml\\/min) (P=ns). No significant differences in systolic or diastolic blood pressure were noticed during the different A-V delays. CONCLUSION: Grafts flowmetry provides an extra tool to direct supportive measures such as cardiac pacing after CABG. DDD mode with A-V delay around 175 ms. should be preferred to allow for maximal myocardial perfusion via the grafts.

  5. Influence of angiographic collateral circulation on myocardial perfusion in patients with chronic total occlusion of a single coronary artery and no prior myocardial infarction.

    Science.gov (United States)

    Aboul-Enein, Fatma; Kar, Saibal; Hayes, Sean W; Sciammarella, Maria; Abidov, Aiden; Makkar, Raj; Friedman, John D; Eigler, Neal; Berman, Daniel S

    2004-06-01

    The functional role of various angiographic grades for coronary collaterals remains controversial. The aim of this study was to assess the influence of the Rentrop angiographic grading of coronary collaterals on myocardial perfusion in patients with single-vessel chronic total occlusion (CTO) and no prior myocardial infarction (MI). The study included 56 patients with single-vessel CTO and no prior MI who underwent rest-stress myocardial perfusion SPECT and coronary angiography within 6 mo. All patients had angiographic evidence of coronary collaterals. Patients were divided according to the Rentrop classification: Group I had grade 1 or 2 (n = 25) and group II had grade 3 collaterals (n = 31). Group I had a higher frequency of resting regional wall motion abnormalities on left ventriculography (52.6% vs. 19.2% [P = 0.019]). The mean perfusion scores of the overall population showed severe and extensive stress perfusion defects (summed stress score of 14.1 +/- 7.1 and summed difference score of 12.9 +/- 6.9) but minimal resting perfusion defects (summed rest score of 1.0 +/- 2.7). No perfusion scores differed between the 2 groups. The perfusion findings suggested that chronic stunning rather than hibernation is the principal cause of regional wall motion abnormalities in these patients. In the setting of single-vessel CTO and no prior MI, coronary collaterals appear to protect against resting perfusion defects. Excellent angiographic collaterals may prevent resting regional wall motion abnormalities but do not appear to protect against stress-induced perfusion defects.

  6. [Myocardial perfusion scintigraphy. Exact and cost-effective coronary disease imaging - secondary publication

    DEFF Research Database (Denmark)

    Hesse, B.; Petersen, C.L.; Marcassa, C.

    2008-01-01

    Mortality rates due to coronary arterial disease (CAD) have declined as result of improved prevention, diagnosis and management, but CAD remains the leading cause of death. Myocardial perfusion scintigraphy (MPS) provides a cost-effective tool for early detection of CAD in symptomatic individuals...

  7. Changes in myocardial perfusion due to physical exercise in patients with stable coronary artery disease

    International Nuclear Information System (INIS)

    Kendziorra, Kai; Foerster, Marcus; Sabri, Osama; Kluge, Regine; Walther, Claudia; Moebius-Winkler, Sven; Conradi, Katrin; Schuler, Gerhard; Hambrecht, Rainer

    2005-01-01

    Percutaneous transluminal coronary angioplasty (PTCA) is one of the main therapy options for patients with coronary artery disease (CAD), resulting in an improvement in myocardial perfusion and exercise capacity. Nevertheless, studies have also demonstrated a positive effect of regular exercise training on myocardial perfusion and maximum exercise capacity. The aim of this study was to evaluate changes in myocardial stress perfusion after 1 year of exercise training in comparison with the effects of PTCA in patients with CAD. In 66 male patients with angiographically confirmed significant coronary artery stenosis in one target vessel, myocardial perfusion scintigraphy was performed at baseline and 12 months after randomisation into either a physical exercise group or a PTCA group. Circumferential count rate profiles in 16 wall segments were classified according to their relative count rate and localisation within or outside the area supplied by the stenosed vessel. Ischaemic segments showed a significant improvement in myocardial count rate within the target area after 12 months in both the PTCA and the training group (PTCA group: from 76.8±4.9% to 86.6±10.9%, p=0.03; training group: from 74.0±7.3% to 83.7±10.8%, p<0.01). Outside the target area only the training group showed a significant improvement (from 77.7±4.4% to 91.7±4.8%, p<0.01). Our data indicate a significant improvement in stress myocardial perfusion in the training group after 12 months. The ischaemia is reduced not only in the target region of the leading stenosis but also in other ischaemic myocardial areas. In contrast, after PTCA stress perfusion improves only in the initially ischaemic parts of the target area. (orig.)

  8. Myocardial perfusion SPECT in a case of retropulmonary looping of left coronary artery in a baby after arterial switch surgery

    International Nuclear Information System (INIS)

    Padma, Subramanyam; Sundaram, Palaniswamy Shanmuga

    2014-01-01

    Pediatric myocardial perfusion imaging (MPI) is not a routine investigation in an Indian setting due to under referrals and logistic problems. However, MPI is a frequently performed and established modality of investigation in adults for the identification of myocardial ischemia and viability. We report myocardial perfusion scintigraphy in a case of retropulmonary looping of left coronary artery in a baby after arterial switch surgery. Adenosine stress MPI revealed a large infarct involving anterior segment with moderate reversible ischemia of the lateral left ventricular segment. Coronary angiogram later confirmed left main coronary artery ostial occlusion with retrograde collateral supply from dilated right coronary artery

  9. Fusion of CT coronary angiography and whole-heart dynamic 3D cardiac MR perfusion: building a framework for comprehensive cardiac imaging.

    Science.gov (United States)

    von Spiczak, Jochen; Manka, Robert; Gotschy, Alexander; Oebel, Sabrina; Kozerke, Sebastian; Hamada, Sandra; Alkadhi, Hatem

    2018-04-01

    The purpose of this work was to develop a framework for 3D fusion of CT coronary angiography (CTCA) and whole-heart dynamic 3D cardiac magnetic resonance perfusion (3D-CMR-Perf) image data-correlating coronary artery stenoses to stress-induced myocardial perfusion deficits for the assessment of coronary artery disease (CAD). Twenty-three patients who underwent CTCA and 3D-CMR-Perf for various indications were included retrospectively. For CTCA, image quality and coronary diameter stenoses > 50% were documented. For 3D-CMR-Perf, image quality and stress-induced perfusion deficits were noted. A software framework was developed to allow for 3D image fusion of both datasets. Computation steps included: (1) fully automated segmentation of coronary arteries and heart contours from CT; (2) manual segmentation of the left ventricle in 3D-CMR-Perf images; (3) semi-automatic co-registration of CT/CMR datasets; (4) projection of the 3D-CMR-Perf values on the CT left ventricle. 3D fusion analysis was compared to separate inspection of CTCA and 3D-CMR-Perf data. CT and CMR scans resulted in an image quality being rated as good to excellent (mean scores 3.5 ± 0.5 and 3.7 ± 0.4, respectively, scale 1-4). 3D-fusion was feasible in all 23 patients, and perfusion deficits could be correlated to culprit coronary lesions in all but one case (22/23 = 96%). Compared to separate analysis of CT and CMR data, coronary supply territories of 3D-CMR-Perf perfusion deficits were refined in two cases (2/23 = 9%), and the relevance of stenoses in CTCA was re-judged in four cases (4/23 = 17%). In conclusion, 3D fusion of CTCA/3D-CMR-Perf facilitates anatomic correlation of coronary lesions and stress-induced myocardial perfusion deficits thereby helping to refine diagnostic assessment of CAD.

  10. Hydrogen ion changes and contractile behavior in the perfused rat heart

    NARCIS (Netherlands)

    Cingolani, H.E.; Maas, A.H.J.; Zimmerman, A.N.E.; Meijler, F.L.

    1975-01-01

    The effect of acid-base alterations was analyzed using isolated rat hearts perfused at constant coronary perfusion pressure, and stimulated to contract at constant rate. The amount of shortening in the major axis and its derivative were measured to assess myocardial contractility. Both the

  11. Transmural myocardial perfusion gradients in relation to coronary artery stenoses severity assessed by cardiac multidetector computed tomography

    DEFF Research Database (Denmark)

    Linde, Jesper James; Kühl, Jørgen Tobias; Hove, Jens Dahlgaard

    2015-01-01

    To assess the relationship between epicardial coronary artery stenosis severity and the corresponding regional transmural perfusion at rest and during adenosine stress, using multidetector computed tomography (MDCT). We evaluated the relationship between the severity of coronary artery diameter...

  12. Localization of coronary artery disease with exercise electrocardiography: correlation with thallium-201 myocardial perfusion scanning

    International Nuclear Information System (INIS)

    Dunn, R.F.; Freedman, B.; Bailey, I.K.; Uren, R.F.; Kelly, D.T.

    1981-01-01

    In 61 patients with single vessel coronary artery disease (70 percent or greater obstruction of luminal diameter in only one vessel) and no previous myocardial infarction, the sites of ischemic changes on 12 lead exercise electrocardiography and on thallium-201 myocardial perfusion scanning were related to the obstructed coronary artery. The site of exercise-induced S-T segment depression did not identify which coronary artery was obstructed. In the 37 patients with left anterior descending coronary artery disease S-T depression was most often seen in the inferior leads and leads V4 to V6, and in the 18 patients with right coronary artery disease and in the 6 patients with left circumflex artery disease S-T depression was most often seen in leads V5 and V6. Although S-T segment elevation was uncommon in most leads, it occurred in lead V1 or a VL, or both, in 51 percent of the patients with left anterior descending coronary artery disease. A reversible anterior defect on exercise thallium scanning correlated with left anterior descending coronary artery disease (probability [p] less than 0.0001) and a reversible inferior thallium defect correlated with right coronary or left circumflex artery disease (p less than 0.0001). In patients with single vessel disease, the site of S-T segment depression does not identify the obstructed coronary artery; S-T segment elevation in lead V1 or aVL, or both, identifies left anterior descending coronary artery disease; and the site of reversible perfusion defect on thallium scanning identifies the site of myocardial ischemia and the obstructed coronary artery

  13. Relations among impaired coronary flow reserve, left ventricular hypertrophy and thallium perfusion defects in hypertensive patients without obstructive coronary artery disease

    International Nuclear Information System (INIS)

    Houghton, J.L.; Frank, M.J.; Carr, A.A.; von Dohlen, T.W.; Prisant, L.M.

    1990-01-01

    Invasive Doppler catheter-derived coronary flow reserve, echocardiographic measurements of left ventricular hypertrophy and intravenous dipyridamole-limited stress thallium-201 scintigraphy were compared in 48 patients (40 were hypertensive or diabetic) with clinical ischemic heart disease and no or minor coronary artery disease. Abnormal vasodilator reserve (ratio less than 3:1) occurred in 50% of the study group and markedly abnormal reserve (less than or equal to 2:1) occurred in 27%. Coronary vasodilator reserve was significantly lower (2.2 +/- 0.8 versus 3.5 +/- 1.3, p = 0.003) and indexed left ventricular mass significantly higher (152.6 +/- 42.2 versus 113.6 +/- 24.0 g, p = 0.0007) in patients with a positive (n = 11) versus a negative (n = 32) thallium perfusion scan. Coronary flow reserve was linearly related in coronary basal flow velocity as follows: y = -0.17x + 4.59; r = -0.57; p = 0.00002. The decrement in flow reserve was not linearly related to the degree of left ventricular hypertrophy. Abnormal vasodilator reserve subsets found in hypertensive patients were defined on the basis of basal flow velocity, indexed left ventricular mass and clinical factors. In this series, diabetes did not cause a detectable additional decrement in flow reserve above that found with hypertension alone. These findings demonstrate that thallium perfusion defects are associated with depressed coronary vasodilator reserve in hypertensive patients without obstructive coronary artery disease. Left ventricular hypertrophy by indexed mass criteria is predictive of which hypertensive patients are likely to have thallium defects

  14. Automated quantitative coronary computed tomography correlates of myocardial ischaemia on gated myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Graaf, Michiel A. de; Boogers, Mark J.; Veltman, Caroline E.; El-Naggar, Heba M.; Bax, Jeroen J.; Delgado, Victoria; Broersen, Alexander; Kitslaar, Pieter H.; Dijkstra, Jouke; Kroft, Lucia J.; Younis, Imad Al; Reiber, Johan H.; Scholte, Arthur J.

    2013-01-01

    Automated software tools have permitted more comprehensive, robust and reproducible quantification of coronary stenosis, plaque burden and plaque location of coronary computed tomography angiography (CTA) data. The association between these quantitative CTA (QCT) parameters and the presence of myocardial ischaemia has not been explored. The aim of the present investigation was to evaluate the association between QCT parameters of coronary artery lesions and the presence of myocardial ischaemia on gated myocardial perfusion single-photon emission CT (SPECT). Included in the study were 40 patients (mean age 58.2 ± 10.9 years, 27 men) with known or suspected coronary artery disease (CAD) who had undergone multidetector row CTA and gated myocardial perfusion SPECT within 6 months. From the CTA datasets, vessel-based and lesion-based visual analyses were performed. Consecutively, lesion-based QCT was performed to assess plaque length, plaque burden, percentage lumen area stenosis and remodelling index. Subsequently, the presence of myocardial ischaemia was assessed using the summed difference score (SDS ≥2) on gated myocardial perfusion SPECT. Myocardial ischaemia was seen in 25 patients (62.5 %) in 37 vascular territories. Quantitatively assessed significant stenosis and quantitatively assessed lesion length were independently associated with myocardial ischaemia (OR 7.72, 95 % CI 2.41-24.7, p 2 = 20.7) and lesion length (χ 2 = 26.0) to the clinical variables and the visual assessment (χ 2 = 5.9) had incremental value in the association with myocardial ischaemia. Coronary lesion length and quantitatively assessed significant stenosis were independently associated with myocardial ischaemia. Both quantitative parameters have incremental value over baseline variables and visually assessed significant stenosis. Potentially, QCT can refine assessment of CAD, which may be of potential use for identification of patients with myocardial ischaemia. (orig.)

  15. Diagnostic value of stress-rest myocardial perfusion imaging in detection of coronary disease in elderly patients

    International Nuclear Information System (INIS)

    Han Pingping; Tian Yueqin; Fang Wei; Shen Rui; Yang Minfu; Wei Hongxing; Guo Xinhua; He Zuoxiang

    2009-01-01

    Objective: Coronary artery disease is one of the most common causes of death in elderly people. Yet, definite diagnosis is a dilemma due to the variety of symptoms and signs. The aim of this study was to evaluate the diagnostic value of nuclear stress-rest myocardial perfusion imaging(MPI) in detection of coronary disease in the elderly. Methods: Two hundred and five elderly subjects (≥60 years old, average of 67 ± 5) who were suspected to have coronary disease, underwent both stress-rest myocardial perfusion imaging (185 with exercise stress and 20 with adenosine stress) and coronary angiography (CAG). All had no pereutaneous coronary intervention (PCI) or coronary artery bypass grafting (CABG). Coronary angiography was used as a 'golden standard' to evaluate the sensitivity, specificity and accuracy of the stress-rest myocardial perfusion imaging. χ 2 -test was used in data analysis with SPSS 15.0. Results: Among 205 patients. there were 57 patients with an abnormal CAG result and 148 patients with a normal result. Of the 57 patients, there were 30 one-, 19 two-, and 8 three-vessel stenosis. Fifteen were mild-, 17 were moderate-, 17 were severe stenosis, and 8 were totally occluded.About 63% (36/57) had positive stress-rest MPI. Of the 148 subjects who had a normal CAG, 135 had negative MPL. The sensitivity.specificity and accuracy of stress MPI were 63% (36/57), 91% (135/148) and 83% (171/205) in patient level.respectively. The di-agnostic sensitivities of stress-rest MPI for detection of one-, two-, and three-vessel stenosis were 57%(17/30), 58% (11/19) and 8/8, respectively. All 185 patients who underwent exemise stress MPI were divided into 2 groups according to whether the patients reached the target heart rate or not at the peak of the test. And 53 patients (29%) were group 1 (reached the target heart rate)and 132 patients (71%) were group 2 (did not reach the target heart rate). The sensitivity of group 1 wag higher than that of group 2, but with no

  16. Decrease in coronary vascular volume in systole augments cardiac contraction.

    Science.gov (United States)

    Willemsen, M J; Duncker, D J; Krams, R; Dijkman, M A; Lamberts, R R; Sipkema, P; Westerhof, N

    2001-08-01

    Coronary arterial inflow is impeded and venous outflow is increased as a result of the decrease in coronary vascular volume due to cardiac contraction. We evaluated whether cardiac contraction is influenced by interfering with the changes of the coronary vascular volume over the heart cycle. Length-tension relationships were determined in Tyrode-perfused rat papillary muscle and when coronary vascular volume changes were partly inhibited by filling it with congealed gelatin or perfusing it with a high viscosity dextran buffer. Also, myocyte thickening during contraction was reduced by placing a silicon tube around the muscle. Increasing perfusion pressure from 8 to 80 cmH2O, increased developed tension by approximately 40%. When compared with the low perfusion state, developed tension of the gelatin-filled vasculature was reduced to 43 +/- 6% at the muscle length where the muscle generates the largest developed tension (n = 5, means +/- SE). Dextran reduced developed tension to 73 +/- 6% (n = 6). The silicon tube, in low perfusion state, reduced the developed tension to 83 +/- 7% (n = 4) of control. Time-control and oxygen-lowering experiments show that the findings are based on mechanical effects. Thus interventions to prevent myocyte thickening reduce developed tension. We hypothesize that when myocyte thickening is prevented, intracellular pressure increases and counteracts the force produced by the contractile apparatus. We conclude that emptying of the coronary vasculature serves a physiological purpose by facilitating cardiomyocyte thickening thereby augmenting force development.

  17. Quantitative myocardial perfusion PET combined with coronary anatomy derived from CT angiography. Validation of a new fusion and visualisation software

    International Nuclear Information System (INIS)

    Fricke, Harald; Weise, Reiner; Burchert, Wolfgang; Fricke, Eva; Elsner, Andreas; Bolte, Matthias; Domik, Gitta; Hoff, Joerg van den

    2009-01-01

    Aim: Dynamic perfusion PET offers a clinical relevant advantage over myocardial perfusion scintigraphy due to its ability to measure myocardial blood flow quantitatively. This leads to an improved detection of multivessel disease and the possibility to assess not only the culprit lesion but lower grade stenoses as well. For appropriate revascularization, perfusion defects must be matched to coronary lesions. It has been shown that image fusion of morphological and functional images is superior to side-by-side analysis. Still, software for quantitative perfusion PET combined with CT angiography is rare. In this paper we present a new software tool for image fusion and visualization of quantitative perfusion PET and coronary morphology derived from CT angiography. Methods: In our software, a PET uptake image is used for manual co-registration. Co-registration results are then applied to the functional data derived from compartment modelling. To evaluate the reproducibility of the manual co-registration, we calculated the deviation between a series of manual co-registrations performed on nine pairs of unregistered PET and CT datasets by five trained participants. Two dimensional transfer functions were used to highlight the coronary arteries from the CT study in the combined data sets. Results: The average Euclidian distances for three references points were between 3.7 and 4.1 mm. The maximum distance was 10.6 mm. By the use of the two dimensional transfer functions, coronary anatomy could be easily visualised either by user-interaction or automatically by use of neuronal networks. Conclusions: With this approach it is possible to combine quantitative perfusion PET with coronary anatomy derived from CT angiography. Our first experiences indicate that manual image fusion with our tool is reproducible and that visualisation of the combined datasets is achieved within short time. (orig.)

  18. Diagnostic and clinical benefit of combined coronary calcium and perfusion assessment in patients undergoing PET/CT myocardial perfusion stress imaging.

    Science.gov (United States)

    Bybee, Kevin A; Lee, John; Markiewicz, Richard; Longmore, Ryan; McGhie, A Iain; O'Keefe, James H; Hsu, Bai-Ling; Kennedy, Kevin; Thompson, Randall C; Bateman, Timothy M

    2010-04-01

    A limitation of stress myocardial perfusion imaging (MPI) is the inability to detect non-obstructive coronary artery disease (CAD). One advantage of MPI with a hybrid CT device is the ability to obtain same-setting measurement of the coronary artery calcium score (CACS). Utilizing our single-center nuclear database, we identified 760 consecutive patients with: (1) no CAD history; (2) a normal clinically indicated Rb-82 PET/CT stress perfusion study; and (3) a same-setting CAC scan. 487 of 760 patients (64.1%) had subclinical CAD based on an abnormal CACS. Of those with CAC, the CACS was > or =100, > or =400, and > or =1000 in 47.0%, 22.4%, and 8.4% of patients, respectively. Less than half of the patients with CAC were receiving aspirin or statin medications prior to PET/CT imaging. Patients with CAC were more likely to be initiated or optimized on proven medical therapy for CAD immediately following PET/CT MPI compared to those without CAC. Subclinical CAD is common in patients without known CAD and normal myocardial perfusion assessed by hybrid PET/CT imaging. Identification of CAC influences subsequent physician prescribing patterns such that those with CAC are more likely to be treated with proven medical therapy for the treatment of CAD.

  19. Diabetes patients show different time-course of myocardial perfusion improvement after coronary artery bypass grafting

    International Nuclear Information System (INIS)

    Lee, J. J.; Seok, J. W.; Eo, J. S.

    2005-01-01

    Diabetes mellitus is an independent risk factor of cardiovascular disease. Diabetes is known to cause microangiopathy. The microangiopathy is hardly detectable on the coronary angiography. Myocardial perfusion imaging shows the resultant perfusion status which reflects the microangiopathy. For patients who underwent revascularization, the microangiopathy could affect the myocardial perfusion improvement. Diabetes patients probably experience the different myocardial perfusion improvement as compared to the non-diabetes patients although they have similar angiographic findings. The aim of this study is to find out whether there is a time-course difference of perfusion improvement between the diabetes and non diabetes patients who showed patent angiographic findings after coronary artery grafting surgery (CABG). A total of 129 patients who underwent coronary artery bypass grafting surgery were enrolled in this study. Myocardial SPECTs performed at previous, short-term (3 month), and mid-term (1 year) to CABG. One-year follow up angiography was done 411±121 days after surgery. Graft patency was determined according to the FitzGibbon et al. Segments were assigned to vascular territories using a 20 segment model. The segments of excellent patency were included in this study. Time course differences of concerned segments were analyzed using RMANOVA. The number of segments enrolled was 764 of diabetes and 1083 of non-diabetes. At short-term follow up, reversibility score was 2.8±8.1% in diabetes and 0.3±7.5% in non-diabetes. At long-term follow up, reversibility score was 1.8±8.0% in diabetes and 0.1±7.3% in non-diabetes. The time-course of reversibility score was significantly different between the diabetes and non diabetes (p<0.001) Diabetic segments showed high residual reversibility score than non-diabetic segments after CABG although the angiographic finding was patent in both groups. This result is maybe attributable to microangiopathy induced by diabetes

  20. Compartment analysis of 125I-labelled albumin washout from coronary vessels of isolated perfused hearts

    International Nuclear Information System (INIS)

    Cheng Eap Ng; Seh-Hoon Song

    1978-01-01

    Albumin labelled with 125 I was used as a tracer to investigate the washout kinetics of plasma from the coronary circulation of isolated perfused feline hearts. Compartmentalization with experimental results showed at least two compartments. The model was compared with a three-compartment model found previously for red blood cells. The results indicate that there is a separation of plasma and RBC in the coronary microcirculation. (author)

  1. Influence of the prevalence of coronary artery disease in patients with normal myocardial perfusion SPECT imaging. Cooperative study in South America

    International Nuclear Information System (INIS)

    Balestrini, V.R.; Arja, V.J.; Sandrin, A.L.; Sala, J.P.; Joekes, S.; Bier, G.; Precoma, D.; Yamada, A.

    2002-01-01

    An important feature of myocardial perfusion imaging is the ability to predict prognosis and identify high- and low-risk patients for coronary events. According to Bayes' theorem, the significance of test's results, relates not only the sensitivity and specificity of a test but also the prevalence of disease in the population under study. Aim: evaluate the relationship between pretest likelihood (PTL) and coronary events (CE) in patients with normal myocardial perfusion SPECT imaging during a long period of time. Material and Methods: The population included 709 patients (411 men and 298 women, mean age 58 years old) who underwent stress/rest myocardial perfusion SPECT imaging at nuclear cardiology laboratories in Argentina and Brazil, with scintigraphic images interpreted as normal. Analyzed variables: clinical, EKG and stress test. Perfusion agents: Tc-99m-tetrofosmin: 36.5%, Tc99m-sestamibi 5.8% and Tl-201 57.7%. Mean follow up: 919 days. CE: soft (unstable angina and need for revascularization) and hard (AMI and cardiac death). Results: Stress test: exercise stress test 72.2%, dipyridamole 25%, adenosine 1.7%, dobutamine 1.1%. PTL [ 9' (M/F): 59/11% (p 78%] 31 vs. 50%. Conclusions: 1) There was a relationship between PTL, events rate and time to event. 2) We found a low hard events rate (0.85%). 3) The results in this group of patients with normal myocardial perfusion SPECT imaging may suggest a guarantee period of low risk of coronary events between 2-3 years. 4) In spite of there is a low event rate in total population with normal myocardial perfusion imaging, patients with highest prevalence of coronary artery disease have more statistical probabilities of coronary events and therefore they have to be watched closely

  2. Pressure-controlled intermittent coronary sinus occlusion (PICSO) in acute ST-segment elevation myocardial infarction: results of the Prepare RAMSES safety and feasibility study

    NARCIS (Netherlands)

    van de Hoef, Tim P.; Nijveldt, Robin; van der Ent, Martin; Neunteufl, Thomas; Meuwissen, Martijn; Khattab, Ahmed; Berger, Rudolf; Kuijt, Wichert J.; Wykrzykowska, Joanna; Tijssen, Jan G. P.; van Rossum, Albert C.; Stone, Gregg W.; Piek, Jan J.

    2015-01-01

    Pressure-controlled intermittent coronary sinus occlusion (PICSO) may improve myocardial perfusion after pPCI. We evaluated the safety and feasibility of PICSO after pPCI for STEMI, and explored its effects on infarct size and myocardial function. Thirty patients were enrolled following successful

  3. Automated quantitative coronary computed tomography correlates of myocardial ischaemia on gated myocardial perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Graaf, Michiel A. de; Boogers, Mark J.; Veltman, Caroline E. [Leiden University Medical Center, Department of Cardiology, Leiden (Netherlands); The Interuniversity Cardiology Institute of The Netherlands, Utrecht (Netherlands); El-Naggar, Heba M.; Bax, Jeroen J.; Delgado, Victoria [Leiden University Medical Center, Department of Cardiology, Leiden (Netherlands); Broersen, Alexander; Kitslaar, Pieter H.; Dijkstra, Jouke [Leiden University Medical Center, Department of Radiology, Division of Image Processing, Leiden (Netherlands); Kroft, Lucia J. [Leiden University Medical Center, Department of Radiology, Leiden (Netherlands); Younis, Imad Al [Leiden University Medical Center, Department of Nuclear Medicine, Leiden (Netherlands); Reiber, Johan H. [Leiden University Medical Center, Department of Radiology, Division of Image Processing, Leiden (Netherlands); Medis medical imaging systems B.V., Leiden (Netherlands); Scholte, Arthur J. [Leiden University Medical Center, Department of Cardiology, Leiden (Netherlands)

    2013-08-15

    Automated software tools have permitted more comprehensive, robust and reproducible quantification of coronary stenosis, plaque burden and plaque location of coronary computed tomography angiography (CTA) data. The association between these quantitative CTA (QCT) parameters and the presence of myocardial ischaemia has not been explored. The aim of the present investigation was to evaluate the association between QCT parameters of coronary artery lesions and the presence of myocardial ischaemia on gated myocardial perfusion single-photon emission CT (SPECT). Included in the study were 40 patients (mean age 58.2 {+-} 10.9 years, 27 men) with known or suspected coronary artery disease (CAD) who had undergone multidetector row CTA and gated myocardial perfusion SPECT within 6 months. From the CTA datasets, vessel-based and lesion-based visual analyses were performed. Consecutively, lesion-based QCT was performed to assess plaque length, plaque burden, percentage lumen area stenosis and remodelling index. Subsequently, the presence of myocardial ischaemia was assessed using the summed difference score (SDS {>=}2) on gated myocardial perfusion SPECT. Myocardial ischaemia was seen in 25 patients (62.5 %) in 37 vascular territories. Quantitatively assessed significant stenosis and quantitatively assessed lesion length were independently associated with myocardial ischaemia (OR 7.72, 95 % CI 2.41-24.7, p < 0.001, and OR 1.07, 95 % CI 1.00-1.45, p = 0.032, respectively) after correcting for clinical variables and visually assessed significant stenosis. The addition of quantitatively assessed significant stenosis ({chi} {sup 2} = 20.7) and lesion length ({chi} {sup 2} = 26.0) to the clinical variables and the visual assessment ({chi} {sup 2} = 5.9) had incremental value in the association with myocardial ischaemia. Coronary lesion length and quantitatively assessed significant stenosis were independently associated with myocardial ischaemia. Both quantitative parameters have

  4. Prognostic value of gated 201Tl myocardial perfusion SPECT imaging in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Li Zicheng; Chen Xiaoming; Xu Hao

    2006-01-01

    Objective: To study the prognostic value of gated 201 Tl myocardial perfusion SPECT imaging in patients with coronary artery disease and assessment of therapy strategy for the individual patient. Methods: Eighty-four patients underwent rest and exercise stress 201 Tl gated myocardial perfusion SPECT imaging and were followed up for (32.92 ± 16.77) months. Images were studied using 17 segments and 1 to 4 scoring. Global summed stress score (SSS), summed rest score (SRS) and summed difference score (SDS=SSS-SRS) were also calculated. Post-stress and rest ejection fraction (EF) were automatically measured. Results: Nine cardiac events occurred (3.90% per year). SSS, SDS, SRS and EF were the independent predictors of cardiac events (P 201 Tl myocardial perfusion SPECT imaging can provide prognostic assessment for the patients with coronary artery disease and guide in selection of therapeutic strategy. Among all of the indices SSS is the best predictors of cardiac events. (authors)

  5. Myocardial perfusion imaging, coronary angiography and histological examination in experimental treatment of Ad-HGF for myocardial infarction

    International Nuclear Information System (INIS)

    Li Jianhua; Feng Jianlin; Cheng Xu; Li Dianfu; Zhang Youfu

    2007-01-01

    Objective: Gene therapy has drawn a great attention. A swine model of adenovirus hepatocyte growth factor(Ad-HGF) treated myocardial infarction(MI) was utilized, with the effect being assessed by rest myocardial perfusion imaging, coronary angiography and histological examination. Methods: Three groups of MI swine treated with Ad-HGF at low dose [n=5, Ad-HGF 10 8 plague forming unit (PFU)/ site], medium dose(n=5, 4 x 10 8 PFU/site), and high dose (n=5, 5 x 10 9 PFU/site), a control group treated with normal saline(NS, n=5) and a blank control group (n=5) underwent rest myocardial perfusion imaging and coronary angiography before and after treatment. The imaging results were analyzed along with histological findings in each group. Results: The state of myocardial perfusion and Rentrop scores remained unchanged in the blank control and NS groups after treatment. Whereas there was a significant improvement in the two variables in all three groups treated with Ad-HGF. The scores of left circumflex coronary artery (LCX) before and after treated were 7.8 ± 1.3 and 16.4 ± 1.1 (low-dose), 8.2 ± 1.6 and 17.6 ± 0.9 (medium-dose), 8.4 ± 1.5 and 19.0 ± 0.7 (high-dose), respectively. No significant differences were noted among the 3 groups. The number of vessels of NS group was markedly less than that of other groups. Conclusion: Myocardial perfusion imaging seems to be more accurate than coronary angiography and histological examination in evaluating the effects of Ad-HGF on myocardial infarction. (authors)

  6. Quantification of reversible perfusion abnormality using exercise-stress thallium SPECT before and after coronary revascularization

    International Nuclear Information System (INIS)

    Nagao, Kazuhiko; Nakata, Tomoaki; Tsuchihashi, Kazufumi

    1994-01-01

    Reversible myocardial perfusion abnormality was quantified by bull's eye and unfolded surface mapping methods in exercise thallium SPECT before and after coronary revascularization in 47 patients with angina pectoris, including 34 patients with previous myocardial infarction (PMI) and 13 with effort angina (AP). There was no difference in the incidence or extent of myocardial ischemia between the 2 groups before revascularization. However, the ischemic scores were significantly smaller in PMI group preoperatively than the reductions of the ischemic scores after revascularization. The ischemic scores, preoperatively estimated reversible perfusion abnormality was 32%, 69% and 48% of the improvement of the ischemic score (extent score, severity score, and ischemic area, respectively). Using the 3 ischemic scores, the improvement of perfusion abnormality was well predicted in 70-89% of AP patients but 35-57% of PMI patients. Thus, quantitative analysis in stress thallium SPECT is useful for detecting myocardial ischemia and evaluating the effect of coronary revascularization. However, about a half of myocardial viability was underestimated in one third of PMI patients by the conventional exercise-stress thallium SPECT study. (author)

  7. Value and limitation of digital subtraction angiography for assessment of myocardial perfusion with varying coronary stenosis

    International Nuclear Information System (INIS)

    Ohtani, Nozomu

    1988-01-01

    We examined the value of digital subtraction angiography (DSA) for the assessment of regional myocardial perfusion by comparing with regional myocardial function in 10 anesthetized dogs. With varying degrees of reduction in left circumflex coronary artery (LCX) blood flow (CBF:categories of stenosis (S1-S5)), myocardial perfusion was assessed by injecting the contrast medium(1ml by power injector) selectively into LCX, and the regional myocardium with contrast was imaged with DSA. We recorded aortic pressure (AOP) and systolic wall thickening (%WTh: sonomicrometry) in the left ventricular posterior wall simultaneously with cine pulse. On the time-density curve obtained from the myocardial regin of interest, we calculated a time interval from the contrast injection to peak concentration (TPC) and exponential washout rate (T). Under varying LCX stenosis, there were no significant change of heart rate and mean AOP and a significant linear correlations were found between %WTh and both 1/TPC(r=0.51)and 1/T(r=0.55). At S1(CBF:100-90% of control), neither %WTh nor 1/TPC differed from control, but 1/T was significantly decreased (80% of contral p<0.01). At S3(CRF:79-60%) to S5(CBF:39-0%), all%WTh, 1/TPC and 1/T were significantly decreased from control (all p<0.01), however, at S5(CBF:39-0%) the value of 1/TPC(71% of control) and 1/T(33%) were not different from that at S4, whereas %WTh was markedly reduced and took place to systolic thinning.. Therefore, in critical coronary stenosis, 1/T was more sensitive than 1/TPC or wall dynamics for assessing myocardial perfusion, however, these indices from DSA had a considerable limitation for evaluating the severity of myocardial ischemia when CBF was markedly reduced. (author)

  8. Sensitivity and specificity of thallium-201 perfusion scintigrams under exercise in the diagnosis of coronary artery disease

    International Nuclear Information System (INIS)

    Verani, M.S.; Marcus, M.L.; Razzak, M.A.; Ehrhardt, J.C.

    1978-01-01

    The specificity and sensitivity of thallium-201 myocardial perfusion imaging (MPI), under exercise, in patients with suspected coronary-obstructive disease was compared with graded exercise ECG tests (GTX) in patients with angiographically normal (N = 34) and obstructed (N = 48) coronary arteries. Of the 34 patients with normal coronaries, only one had a perfusion defect on the MPI (specificity 97%). Of the 48 patients with coronary obstructive disease (>50% obstruction of at least one coronary vessel), MPI was positive in 38 (sensitivity 79%). In contrast, the GTX had a specificity of 62% and sensitivity of 88% if nondiagnostic GTX tests are excluded. When the MPI and the GTX were used in combination, however, the sensitivity of detecting patients with coronary obstructive disease was increased to 94% (p < 0.01). The MPI was particularly useful in the evaluation of the 26 patients with nondiagnostic GTX. In this group, 24 of the 26 patients were correctly identified by the MPI with respect to the presence or absence of coronary-obstructive disease. In the 14 patients with a history of classical angina but with normal coronaries, the MPI was negative in 13 and positive in one, thus suggesting that in the majority of these patients transient transmural myocardial ischemia probably does not occur during exercise. The presence or absence of angiographically demonstrable coronary collateral vessels did not seem to influence the exercise MPI in patients with coronary-obstructive disease. Thus, although the MPI does not correctly identify all patients with either coronary-obstructive disease or normal coronary arteries, it is helpful in patients who have a nondiagnostic GTX. Furthermore, when used in combination with the GTX, the MPI significantly increases the likelihood that significant coronary-obstructive disease is present when both tests are positive, and that coronary disease is absent when both tests are negative

  9. Confluence of depression and acute psychological stress among patients with stable coronary heart disease: effects on myocardial perfusion.

    Science.gov (United States)

    Burg, Matthew M; Meadows, Judith; Shimbo, Daichi; Davidson, Karina W; Schwartz, Joseph E; Soufer, Robert

    2014-10-30

    Depression is prevalent in coronary heart disease (CHD) patients and increases risk for acute coronary syndrome (ACS) recurrence and mortality despite optimal medical care. The pathways underlying this risk remain elusive. Psychological stress (PS) can provoke impairment in myocardial perfusion and trigger ACS. A confluence of acute PS with depression might reveal coronary vascular mechanisms of risk. We tested whether depression increased risk for impaired myocardial perfusion during acute PS among patients with stable CHD. Patients (N=146) completed the Beck Depression Inventory-I (BDI-I), a measure of depression linked to recurrent ACS and post-ACS mortality, and underwent single-photon emission computed tomography myocardial perfusion imaging at rest and during acute PS. The likelihood of new/worsening impairment in myocardial perfusion from baseline to PS as a function of depression severity was tested. On the BDI-I, 41 patients scored in the normal range, 48 in the high normal range, and 57 in the depressed range previously linked to CHD prognosis. A BDI-I score in the depressed range was associated with a significantly greater likelihood of new/worsening impairment in myocardial perfusion from baseline to PS (odds ratio =2.89, 95% CI: 1.26 to 6.63, P=0.012). This remained significant in models controlling ACS recurrence/mortality risk factors and medications. There was no effect for selective serotonin reuptake inhibitor medications. Depressed patients with CHD are particularly susceptible to impairment in myocardial perfusion during PS. The confluence of PS with depression may contribute to a better understanding of the depression-associated risk for ACS recurrence and mortality. © 2014 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  10. The clinical value of adenosine triphosphate stress myocardial perfusion tomography for detecting coronary artery disease

    International Nuclear Information System (INIS)

    Yao Zhiming; He Qing; Qu Wanying; Yu Xue; Han Lijun; Yu Zhiguo; Li Wei; Zeng Xuezhai; Zhu Ming; Zhao Hongshan

    2002-01-01

    Objective: To study the clinical value of adenosine triphosphate stress myocardial perfusion tomography imaging (ATP-MPI) in detection of coronary artery disease (CAD). Methods: There were 278 patients underwent ATP-MPI, 51 patients of them also underwent coronary angiography (CAG). Seventy-three patients underwent stress-rest myocardial perfusion tomography imaging with multi-stage submaximal exercise test (ST-MPI) and CAG serving as control group. Results: 1) Side effects: there were 11 different symptoms and atrioventricular conduction block (10 patients), sinoatrial conduction block (2 patients) occurred during ATP stress. Allopathy or interruption of ATP stress did not happen. 2) The sensitivity and specificity of ATP-MPI in detection of CAD were 97.1% and 82.4%, respectively, and those in detection of ≥50% narrowing coronary artery were 91.0% and 94.7%, respectively. 3) In patients without myocardial infarction, the sensitivity and specificity of ATP-MPI in detection of myocardial ischemia were comparable to those of ST-MPI. Conclusion: ATP-MPI is an accurate, safe modality and is comparable to ST-MPI in the detection of CAD

  11. The clinical application value of myocardial perfusion imaging in evaluating coronary artery myocardial bridge patients with symptoms

    International Nuclear Information System (INIS)

    Wang Yuetao; Fu Ning; Ding Xuemei; Lu Cunzhi; Zhu Feng; Wang Guanmin; Huang Yijie; Wang Linguang

    2008-01-01

    Objective: Myocardial bridge is a common inborn coronary artery anomaly, myocardial bridge may be associated with myocardial ischemia. Only a few patients with coronary artery myocardial bridge were evaluated with nuclear medicine techniques. The aim of this study was to investigate the role of nuclear cardiology with myocardial perfusion technique in symptomatic myocardial bridge patients. Methods Nineteen myocardial bridge patients with the symptoms of chest pain and chest distress were analyzed retrospectively. 99 Tc m -methoxyisobutylisonitrile (MIBI) myocardial perfusion images (both exercise and rest) were performed in all. Imaging results were compared with the results of movement electrocardiogram (ECG) and coronary arteriography. The t test or χ 2 test was used to statistically analyze the data with Stata 7.0 software. Results: Of the 19 patients, 18 patients had myocardial bridge locating at the left anterior descending artery, 1 patient at the left anterior descending and left circumflex artery, the mean angiographic systolic occlusion within the myocardial bridge was (65.4 ± 22.1)%. Of these 19 patients, Exercise-rest 99 Tc m -MIBI myocardial perfusion imaging defined positive myocardial ischemia in 10 and negative in 9 patients. Of the 10 patients with 99 Tc m -MIBI myocardial perfusion imaging defined myocardial ischemia, 8 had reversible radioactive defect of partial anterior wall and (or) apex, 1 had reversible defect of post lateral wall and post septal wall, and 1 had reversible defect of inferior wall. The positive predictive value of myocardial perfusion imaging was 52.6% (10/19), which was higher than movement ECG [21.1% (4/19), χ 2 = 4.07, P 99 Tc m -MIBI myocardial periusion imaging defined myocardial ischemia. Six cases with Grade II stenosis, two were 99 Tc m -MIBI myocardial perfusion imaging defined myocardial ischemia. Eight cases with Grade III stenosis, seven were 99 Tc m -MIBI myocardial perfusion imaging defined myocardial

  12. Diagnosing coronary artery disease after a positive coronary computed tomography angiography

    DEFF Research Database (Denmark)

    Nissen, L; Winther, S; Westra, J

    2018-01-01

    Aims: Perfusion scans after coronary computed tomography angiography (CCTA) in patients with suspected coronary artery disease (CAD) may reduce unnecessary invasive coronary angiographies (ICAs). However, the diagnostic accuracy of perfusion scans after primary CCTA is unknown. The aim...

  13. Myocardial perfusion after prolonged submaximal exercise in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Flotats, A.; Mena, E.; Camacho, V.; Tembl, A.; Hernandez, M.A.; Estorch, M.; Carrio, I.; Serra-Grima, R.

    2002-01-01

    Aim: Exercise training in patients with coronary artery disease (CAD) has established benefits. We assessed myocardial perfusion after submaximal but prolonged exercise in patients with CAD, who were enrolled in supervised exercise rehabilitation programs. Material and Methods: Nine patients with CAD enrolled in supervised exercise rehabilitation programs (7 men, 2 women; mean age 54±9 years), 7 with prior AMI and 2 with re-vascularized (CABG) multiple vessel disease, were encouraged to walk/run actively around the perimeter of our Hospital during the annual social sporting event organised in our Institution. Patients were studied by means of perfusion Tc-99m tetrofosmin SPECT imaging after prolonged exercise and at rest (gated SPECT), for two consecutive years. All patients remained symptom free during this interval period. Quantitative analysis was performed dividing polar map images in 13 segments. Tracer activity 9% in the resting image. The analysis was focused on those segments showing perfusion defects. Results: No symptoms other than fatigue were registered during prolonged exercise (range 1-2 hr). There were no significant differences in distance covered (7,462±3,031 m vs. 8,456±2,998 m), heart rate (92±11 bpm vs. 85±13 bpm) and rate-pressure product at the end of exercise (10,804±2,467 vs. 10,403±2,955) or gated SPECT calculated LVEF (44%±19 vs. 46%±20) between the two consecutive annual sporting events. Tracer activity in segments with perfusion defects did not significantly differ between both events. Overall agreement between both examinations regarding patient classification as having scar/ischemia was 77% (kappa=0.49). There was one patient who showed partial reversibility in three segments, consistent with mild anteroapical ischemia, only in the first examination. On the other hand, another patient showed reversibility in one segment (medium septum), only in the second examination, when he covered a distance 1.3 times superior. Conclusions

  14. Combined anatomical and functional imaging using coronary CT angiography and myocardial perfusion SPECT in symptomatic adults with abnormal origin of a coronary artery.

    Science.gov (United States)

    Uebleis, C; Groebner, M; von Ziegler, F; Becker, A; Rischpler, C; Tegtmeyer, R; Becker, C; Lehner, S; Haug, A R; Cumming, P; Bartenstein, P; Franz, W M; Hacker, M

    2012-10-01

    There has been a lack of standardized workup guidelines for patients with congenital abnormal origin of a coronary artery from the opposite sinus (ACAOS). We aimed to evaluate the use of cardiac hybrid imaging using multi-detector row CT (MDCT) for coronary CT angiography (Coronary CTA) and stress-rest myocardial perfusion SPECT (MPS) for comprehensive diagnosis of symptomatic adult patients with ACAOS. Seventeen symptomatic patients (12 men; 54 ± 13 years) presenting with ACAOS underwent coronary CTA and MPS. Imaging data were analyzed by conventional means, and with additional use of 3D image fusion to allocate stress induced perfusion defects (PD) to their supplying coronary arteries. An anomalous RCA arose from the left anterior sinus in eight patients, an abnormal origin from the right sinus was detected in nine patients (5 left coronary arteries, LCA and 4 LCx). Five of the 17 patients (29%) demonstrated a reversible PD in MPS. There was no correlation between the anatomical variants of ACAOS and the presence of myocardial ischemia. Image fusion enabled the allocation of reversible PD to the anomalous vessel in three patients (two cases in the RCA and the other in the LCA territory); PD in two patients were allocated to the territory of artery giving rise to the anomalies, rather than the anomalies themselves. In a small cohort of adult symptomatic patients with ACAOS anomaly there was no relation found between the specific anatomical variant and the appearance of stress induced myocardial ischemia using cardiac hybrid imaging.

  15. Distribution of coronary arterial capacitance in a canine model.

    Science.gov (United States)

    Lader, A S; Smith, R S; Phillips, G C; McNamee, J E; Abel, F L

    1998-03-01

    The capacitative properties of the major left coronary arteries, left main (LM), left anterior descending (LAD), and left circumflex (LCX), were studied in 19 open-chest isolated dog hearts. Capacitance was determined by using ramp perfusion and a left ventricular-to-coronary shunt diastolic decay method; both methods gave similar results, indicating a minimal systolic capacitative component. Increased pericardial pressure (PCP), 25 mmHg, was used to experimentally alter transmural wall pressure. The response to increased PCP was different in the LAD vs. LCX; increasing PCP decreased capacitance in the LCX but increased capacitance in the LAD. This may have been due to the different intramural vs. epicardial volume distribution of these vessels and a decrease in intramural tension during increased PCP. Increased PCP decreased LCX capacitance by approximately 13%, but no changes in conductance or zero flow pressure intercept occurred in any of the three vessels, i. e., evidence against the waterfall theory of vascular collapse at these levels of PCP. Coronary arterial capacitance was also linearly related to perfusion pressure.

  16. Tissue perfusion as a key underlying concept of pressure ulcer development and treatment.

    Science.gov (United States)

    Wywialowski, E F

    1999-03-01

    The purpose of this article is to refine and advance the theory that tissue perfusion is the key concept in the development and delayed healing of pressure ulcers. The person likely to have (be at risk for) pressure ulcers is at greater risk for inadequate tissue perfusion generally and specifically at pressure points. Accordingly, the tissue perfusion theory of pressure ulcer development states that the factors that contribute to inadequate tissue perfusion should be used to predict (identify risk factors for) pressure ulcer development and delayed healing. Factors influencing a person's adequacy of tissue perfusion need to be assessed to identify risk for pressure ulcers. In addition, adequate tissue perfusion needs to be maintained to provide for healing of such wounds. Current beliefs about the causes and prevention of pressure ulcers are described. Physiologic components of the tissue perfusion theory are discussed: cellular exchange of nutrients and wastes, autoregulation of blood flow at the cellular level, and regulatory mechanisms that affect tissue perfusion when it is significantly compromised. The North American Nursing Diagnosis Association (NANDA) framework is used to classify or group examples of common pathophysiologic, treatment-related, situational, and maturational factors. Implications for research, practice, and education also are discussed.

  17. Spatial interaction between tissue pressure and skeletal muscle perfusion during contraction.

    Science.gov (United States)

    van Donkelaar, C C; Huyghe, J M; Vankan, W J; Drost, M R

    2001-05-01

    The vascular waterfall theory attributes decreased muscle perfusion during contraction to increased intramuscular pressure (P(IM)) and concomitant increase in venous resistance. Although P(IM) is distributed during contractions, this theory does not account for heterogeneity. This study hypothesises that pressure heterogeneity could affect the interaction between P(IM) rise and perfusion. Regional tissue perfusion during submaximum (100kPa) tetanic contraction is studied, using a finite element model of perfused contracting skeletal muscle. Capillary flow in muscles with one proximal artery and vein (SIM(1)) and with an additional distal artery and vein (SIM(2)) is compared. Blood flow and pressures at rest and P(IM) during contraction ( approximately 25kPa maximally) are similar between simulations, but capillary flow and venous pressure differ. In SIM(2), venous pressure and capillary flow correspond to P(IM) distribution, whereas capillary flow in SIM(1) is less than 10% of flow in SIM(2), in the muscle half without draining vein. This difference is caused by a high central P(IM), followed by central venous pressure rise, in agreement with the waterfall theory. The high central pressure (SIM(1)), obstructs outflow from the distal veins. Distal venous pressure rises until central blood pressure is reached, although local P(IM) is low. Adding a distal vein (SIM(2)) restores the perfusion. It is concluded that regional effects contribute to the interaction between P(IM) and perfusion during contraction. Unlike stated by the vascular waterfall theory, venous pressure may locally exceed P(IM). Although this can be explained by the principles of this theory, the theory does not include this phenomenon as such.

  18. Dynamic CT myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Caruso, Damiano; Eid, Marwen; Schoepf, U. Joseph; Jin, Kwang Nam; Varga-Szemes, Akos; Tesche, Christian; Mangold, Stefanie

    2016-01-01

    Highlights: • CT myocardial perfusion provides functional assessment of the myocardium. • CCTA is limited in determining the hemodynamic significance of coronary stenosis. • CT-MPI can accurately detect hemodynamically significant coronary artery stenosis. - Abstract: Non-invasive cardiac imaging has rapidly evolved during the last decade due to advancements in CT based technologies. Coronary CT angiography has been shown to reliably assess coronary anatomy and detect high risk coronary artery disease. However, this technique is limited to anatomical assessment, thus non-invasive techniques for functional assessment of the heart are necessary. CT myocardial perfusion is a new CT based technique that provides functional assessment of the myocardium and allows for a comprehensive assessment of coronary artery disease with a single modality when combined with CTA. This review aims to discuss dynamic CT myocardial perfusion as a new technique in the assessment of CAD.

  19. Dynamic CT myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Caruso, Damiano [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiological Sciences, Oncological and Pathological Sciences, University of Rome “Sapienza”, Latina (Italy); Eid, Marwen [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC (United States); Jin, Kwang Nam [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiology, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Seoul (Korea, Republic of); Varga-Szemes, Akos [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Tesche, Christian [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Cardiology and Intensive Care Medicine, Heart Center Munich-Bogenhausen, Munich (Germany); Mangold, Stefanie [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, Tuebingen (Germany); and others

    2016-10-15

    Highlights: • CT myocardial perfusion provides functional assessment of the myocardium. • CCTA is limited in determining the hemodynamic significance of coronary stenosis. • CT-MPI can accurately detect hemodynamically significant coronary artery stenosis. - Abstract: Non-invasive cardiac imaging has rapidly evolved during the last decade due to advancements in CT based technologies. Coronary CT angiography has been shown to reliably assess coronary anatomy and detect high risk coronary artery disease. However, this technique is limited to anatomical assessment, thus non-invasive techniques for functional assessment of the heart are necessary. CT myocardial perfusion is a new CT based technique that provides functional assessment of the myocardium and allows for a comprehensive assessment of coronary artery disease with a single modality when combined with CTA. This review aims to discuss dynamic CT myocardial perfusion as a new technique in the assessment of CAD.

  20. Feasibility and diagnostic power of transthoracic coronary Doppler for coronary flow velocity reserve in patients referred for myocardial perfusion imaging

    Directory of Open Access Journals (Sweden)

    Nylander Eva

    2008-03-01

    Full Text Available Abstract Background Myocardial perfusion imaging (MPI, using single photon emission computed tomography (SPECT is a validated method for detecting coronary artery disease. Transthoracic Doppler echocardiography (TTDE of flow at rest and during adenosine provocation has previously been evaluated in selected patient groups. We therefore wanted to compare the diagnostic ability of TTDE in the left anterior descending coronary artery (LAD to that of MPI in an unselected population of patients with chest pain referred for MPI. Our hypothesis was that TTDE with high accuracy would identify healthy individuals and exclude them from the need for further studies, enabling invasive investigations to be reserved for patients with a high probability of disease. Methods Sixty-nine patients, 44 men and 25 women, age 61 ± 10 years (range 35–82, with a clinical suspicion of stress induced myocardial ischemia, were investigated. TTDE was performed at rest and during adenosine stress for myocardial scintigraphy. Results We found that coronary flow velocity reserve (CFVR determined from diastolic measurements separated normal from abnormal MPI findings with statistical significance. TTDE identified coronary artery disease, defined from MPI, as reversible ischemia and/or permanent defect, with a sensitivity of 60% and a specificity of 79%. The positive predictive value was 43% and the negative predictive value was 88%. There was an overlap between groups which could be due to abnormal endothelial function in patients with normal myocardial perfusion having either hypertension or diabetes. Conclusion TTDE is an attractive non-invasive method to evaluate chest pain without the use of isotopes, but the diagnostic power is strongly dependent on the population investigated. Even in our heterogeneous clinical cardiac population, we found that CFVR>2 in the LAD excluded significant coronary artery disease detected by MPI.

  1. Prognostic value of Angiographic Perfusion Score (APS) following percutaneous interventions in acute coronary syndromes.

    Science.gov (United States)

    Narain, V S; Fischer, L; Puri, A; Sethi, R; Dwivedi, S K

    2013-01-01

    Identifying reperfusion and predicting post procedure risk is important following Percutaneous Coronary Interventions (PCI). An Angiographic Perfusion Score (APS) combining TIMI flow (TFG) and myocardial perfusion (TMPG) grades before and after PCI can accurately measure both epicardial and myocardial perfusion and predict Major Adverse Cardiac Events (MACE). APS was calculated in 226 (88 ST elevation Myocardial Infarction (STEMI) and 138 Non STEMI) patients. Maximum score being 12, reperfusion was defined as failed: 0-3, partial: 4-9, and full APS: 10-12. Thirty day MACE were observed. APS identified reperfusion significantly more than TMPG alone (STEMI: 50.6% vs 11.8% (p APS group (1.8% vs 22.5%) (p APS detects more low risk reperfused patients, post PCI. Copyright © 2012. Published by Elsevier B.V.

  2. Applications of radionuclide myocardial perfusion imaging in acute coronary syndrome

    International Nuclear Information System (INIS)

    Han Pingping; Tian Yueqin

    2008-01-01

    In recent years, acute coronary syndrome(ACS) has been getting more and more attentions. Radionuclide myocardial perfusion imaging (MPI) can make a quick accurate diagnosis for patients with acute chest pain who cann't be diagnosed by conventional methods. The sensitivity and negative predictive value of MPI are relatively high. Besides, MPI can be applicated in the detection of ischemic and infarct size and degree, the risk stratification and the assessment of prognosis of the patients with ACS, and the appraisal of the effect of strategies. (authors)

  3. Myocardial perfusion scintigraphy fi ndings in patients with mild coronary atherosclerotic lesions on coronary angiography

    Directory of Open Access Journals (Sweden)

    Zeki Dostbil

    2010-09-01

    Full Text Available Objectives: Myocardial perfusion scintigraphy (MPS iswidely used in functional assessment of myocardial per-fusion. But, some study results are in contradiction withseverity of coronary artery disease detected by coronaryangiography (CA. It is frequently encountered case thatCA is completely normal whereas MPS describes isch-emia. In this study, we aimed to investigate whether mildatherosclerotic lesions cause ischemia.Materials and methods: MPS with 99mTc-MIBI was per-formed in 52 patients who applied to cardiology clinics forhistory of chest pain and underwent diagnostic CA within3 months.Results: In 22 of 52 patients with mild atherosclerotic le-sions, ischemia in various degrees was detected on MPS.In statistical analysis, any signifi cant relationship was notfound between ischemia and gender, hypertension, DM,dyslipidemia, smoking, mitral valve insuffi ciency, left ven-tricular hypertrophy, exercise testing result and affectedcoronary artery.Conclusion: Our study fi ndings have shown that mild ath-erosclerotic lesions even at very early stage may causemyocardial ischemia

  4. Optimization of perfusion studies using Atropine

    International Nuclear Information System (INIS)

    Alvarado, A.N.; Valle, V.M.; Montoya, M.J.; Eskenazi, E.S.; Montiel, M.L.; Cueto, C.C.

    2002-01-01

    The studies of myocardial perfusion require an adequate stress; exercise or pharmacological. Every day, more pharmacological studies are performed, specially in some group of patients (women, AMI, etc). There some drugs that are used for this purpose, as adenosine and dobutamine. However, their cost and the lack of availability and infrastructure in our country do not allow there routinely use. We performed dipyridamol as a pharmacological stress, however in some patients there is a doubt regarding if the pharmacological effect was adequate. Atropine is a drug that is frequently used for different purpose and it is well know its tachycardic response. We present and alternative technique, using dipyridamol-atropine as a protocol of stress perfusion study. Our goal was to correlate the standard dipyridamol -thallium perfusion study and the dipyridamol -atropine-perfusion in patients with chronic coronary disease. We evaluated 6 patients (5 males) with stable angina and chronic coronary disease. A standard dipyridamol-thallium study was performed in all of them. Dipyridamole was administered intravenously at a rate of 0.14 mg/kg/min over 6 min for a total of 0.84 mg/kg body weight. Blood pressure, heart rate, EKG and symptoms were monitored before, during and after the pharmacological infusion. Two minutes after the infusion was completed, the radiotracer was injected intravenously. In the next 6 months, without any modification of the clinical situation (symptoms and therapy) a new dipyridamol study was performed, using 1 mg of atropine after the administration of dipyridamol. There were no differences in the collateral effects and we observed and average increase of 30% in the heart rate in relation with the study using dipyridamol alone. The addition of atropine to the standard dipyridamol perfusion study is safe, cheaper and improved the detection of perfusion defects in patients with coronary artery disease

  5. Comparative study of adenosine and exercise 201Tl myocardial perfusion tomographic imaging for detection of coronary heart disease

    International Nuclear Information System (INIS)

    Wang Xiong

    1997-01-01

    To compare diagnostic accuracy of adenosine and exercise 201 Tl myocardial perfusion tomographic imaging for detection of coronary heart disease (CHD) in patients with a normal rest ECG and no history of myocardial infarction, 81 patients with CHD and 10 normal control subjects underwent adenosine myocardial perfusion imaging, exercise nuclide myocardial perfusion imaging was performed in 117 patients with CHD and 16 normal control subjects, two groups also had coronary arteriography. Both exercise and adenosine testing parameters were analysed. It is shown: 1) The sensitivity and specificity for detection of CHD were 79% vs 80% for adenosine group and 81% vs 81% for exercise myocardial perfusion imaging group respectively. There was no significant difference in comparison with two matched groups (χ 2 = 1.13, χ 2 = 0.18, χ 2 = 0.12, P>0.05). 2) Side effects induced by adenosine accounted for 89% of patients, all symptoms were mild and disappeared quickly after the termination of the study except in 2 cases withdrawal of infusion needed because of severe angina pectoris. Adenosine myocardial perfusion imaging is a safe and sensitive method for detection of CHD. The diagnostic value of adenosine test is similar to that of exercise myocardial perfusion imaging and particularly useful in evaluating patients unable to perform exercise test or achieve adequate level of exercise

  6. Evaluation of hemodynamic significance of coronary fistulae. Diagnostic integration between coronary angiography and stress/rest myocardial scintigraphy; Valutazione del significato emodinamico di fistole coronariche artero-venose. Integrazione diagnostica tra angiografia coronarica e scintigrafia miocardica a riposo e sotto sforzo

    Energy Technology Data Exchange (ETDEWEB)

    Rubini, G.; Sebastiani, M. [Bari Univ., Bari (Italy). Cattedra di Medicina Nucleare; Ettorre, G. C. [Foggia Univ., Foggia (Italy). Cattedra di Radiologia; Bovenzi, F. [Ospedale Policlinico, Unita' Operativa di Cardiologia, Bari (Italy)

    2000-12-01

    It is here reported on the importance of the integration of data obtained from digital coronary angiography and stress/rest {sup 99m}Tc sestamibi myocardial perfusion single photon emission tomography in evaluationing the hemodynamic significance of coronary arteriovenous fistulae. Coronary fistulae were detected with coronary angiography in 9 patients. All patients underwent clinical examination, trans thoracic echocardiography, stress electrocardiogram and stress/rest {sup 99m}Tc sestamibi myocardial perfusion single photon emission tomography. Stress/rest {sup 99m}Tc sestamibi myocardial perfusion single photon tomography and stress electrocardiogram showed stress-induced myocardial ischemia in 2 patients. The first patient with familial predisposition and risk factors for ischemic heart disease presented a mesocardic heart murmur on clinical examination. At stress ECG (125 Watt, 153 b/m max frequency 93%, arterial pressure 230 mmHg, max frequency pressure product 35200) ischemic alterations were recorded at the first minute of the second stage of the Bruce protocol. Coronary angiography detected a circumflex artery fistula in the coronary sinus. Stress/rest {sup 99m}Tc sestamibi myocardial perfusion single photon emission tomography for the evaluation of stress/rest perfusion detected a reversible perfusion defect of the proximal portion of the posterolateral and lateral walls, thus confirming the hemodynamic importance of the flow through the fistula during stress cycloergometric testing. In the second patient familial predisposition to ischemic heart disease and previous inferior wall myocardial infarction and non-significant stress ECG, coronary angiography identified a suocclusive stenosis of the right coronary artery and anomaly between the anterior interventricular artery and the left pulmonary artery. The presence of the contrast medium in the left pulmonary artery identified a flow from the left ventricle to the left pulmonary artery. Good angiographic

  7. ABC of the cardiac magnetic resonance. Part 1: perfusion, viability and coronary anatomy

    International Nuclear Information System (INIS)

    Loureiro, Ricardo; Rached, Heron; Castro, Claudio C.; Cerri, Giovanni G.; Favaro, Daniele; Baptista, Luciana; Andrade, Joalbo; Rochitte, Carlos E.; Parga Filho, Jose; Avila, Luiz F.; Piva, Rosa M.V.

    2003-01-01

    The objective of this work is to demonstrate the fundamental concepts, the basic sequences and the clinical and potential applications of cardiac magnetic resonance as a diagnostic technique in updated radiology and cardiology practices. In this second part, we present basic aspects of the cardiac magnetic resonance application in the coronary anatomy and myocardial perfusion and viability. (author)

  8. Myocardial perfusion scintigraphy in identification and localization of individual coronary lesions

    Directory of Open Access Journals (Sweden)

    Baškot Branislav

    2004-01-01

    Full Text Available The aim of this study was to evaluate the accuracy of myocardial perfusion scintigraphy with technetium-99m tetrofosmin by single-photon emission computed tomography (SPECT, using one-day protocol in the identification and localization of individual stenosed coronary vessels. Sixty-eight patients with suspected coronary artery disease (CAD were studied. In thirty of them coronary angiography showed significant stenosis (³50%. Nine patients were with one-vessel disease, 11 were with two-vessel disease, and 10 were with three-vessel disease. All the patients were administered two i.v. injections of 99mTc tetrofosmin, one at peak pharmacologic exercise (1-3 min after i.v. administration of dipiridamol 0.56 mg per kg during 4 min 370 MBq, and the other 740 MBq at rest 3 hrs after the exercise test (acquisition was obtained 15-30 min after injections for both studies. Overall sensitivity, specificity, and diagnostic accuracy in the identification of individual stenosed coronary vessels were 90%, 86%, and 88%, respectively. Sensitivity, specificity, and accuracy in each of the individual vascular territories were not significantly different: LAD (96% 64%, and 75%, ACx (73%, 100%, and 94%, RCA (95%, 93%, and 94%. The results of this study demonstrated one-day 99mTc-tetrofosmin SPECT scintigraphy to be suitable and accurate technique for the identification and localization of individual stenosed coronary vessels, as well as a highly sensitive method in the recognition of one- and multiple-vessel diseases of coronary arteries.

  9. Role of myocardial perfusion scintigraphy post invasive coronary angiography in patients with myocardial infarction

    International Nuclear Information System (INIS)

    Harisankar, C.N.B.; Mittal, Bhagwant Rai; Kamaleshwaran, K.K.; Bhattacharya, Anish; Singh, Baljinder; Mahajan, Rajiv

    2010-01-01

    The presence of severe hypokinesia or akinesia and near complete stenotic lesions on coronary angiography, in a patient with acute myocardial infarction raises a question of viability in the involved territory and its response to revascularization. The decision of revascularization can be effectively taken after myocardial perfusion scintigraphy (MPS). Aim: To evaluate the role of MPS in patients with acute or recent myocardial infarction after invasive coronary angiography. Materials and Methods: Thirty-five patients (27 Males, 8 Females; Mean age 54 years) with acute myocardial infarction, who underwent invasive angiography, were included prospectively. Invasive angiography was attempted during the episode of acute chest pain in 20 patients. Fifteen patients underwent angiography without MPS because of non-availability of MPS at the time of initial presentation in the referring hospital. Revascularization was deferred because of complete/near complete block of artery with hypokinesia/akinesia of the distal LV segments in 32/35 patients and 50 to 70% block in 3/35. These patients were subjected to MPS. Results: Twenty patients underwent stress MPS and 15 underwent nitrate-augmented rest re-distribution study (RR study). Imaging was performed using the hybrid SPECT/CT system. The average defect size of the perfusion defect was 34% (5 - 57% range). Sixteen patients (46%) had fixed perfusion defects. Reversible ischemia was present in 19 (54%). Ten patients had a 10% of the LV myocardium, and underwent the invasive revascularization procedure. Conclusion: MPS is invaluable in patients who have total/near total occlusion of the coronary artery and distal segment hypokinesia or akinesia on invasive angiography. One in four patients, deemed to have non-viable myocardium, underwent an invasive revascularization after undergoing MPS. (author)

  10. The usefulness of planar thallium myocardial perfusion imaging in the diagnosis of coronary artery disease

    International Nuclear Information System (INIS)

    Johannesen, K.A.; Andersen, K.; Foelling, M.; Vik-Mo, H.

    1991-01-01

    Stress thallium scintigraphy was performed in 60 patients with chest pain of uncertain origin. Myocardial ischemia was identified in 91% og the 47 patients who had angiographically significant coronary artery stenosis. Sensitivity of thallium scintigraphy was highest in patients with stenosis in the left descending coronary artery (LAD); 91% of the patients had abnormal thallium as compared with 67% of the patients with normal LAD, but significant stenosis in the circumflex artery and/or the right coronary artery. Perfusion defects in the circumflex or right coronary artery regions were detected in only 50% of the patients with multiple vessel disease. The authors conclude that stress thallium scintigraphy is a useful diagnostic procedure in patients with chest pain of uncertain origin and identifies the patients to be selected for coronary artery angiography. 15 refs., 2 figs., 2 tabs

  11. Protective effect of active perfusion in porcine models of acute myocardial ischemia

    Science.gov (United States)

    Feng, Zanxiang; Mao, Zhifu; Dong, Shengjun; Liu, Baohui

    2016-01-01

    Mortality rates associated with off-pump coronary artery bypass (CAB) are relatively high, as the majority of patients requiring CAB are at a high risk for cardiac events. The present study aimed to establish porcine models of acute myocardial ischemia, and evaluate the protective role of shunt and active perfusion. A total of 30 pigs were randomly assigned to five groups, as follows: i) Sham (control); ii) A1 (shunt; stenosis rate, 55%); iii) A2 (shunt; stenosis rate, 75%); iv) B1 (active perfusion; stenosis rate, 55%); and v) B2 (active perfusion; stenosis rate, 75%) groups. Aortic pressure (P0), left anterior descending coronary pressure (P1), and coronary effective perfusion pressure (P1/P0) were measured. The expression levels of tumor necrosis factor-α (TNF-α), cardiac troponin (cTnI), creatine kinase-myocardial band (CK-MB), interleukin (IL)-6, IL-10, B-cell lymphoma 2 (Bcl-2), and caspase-3 were detected using enzyme-linked immunosorbent assay or western blotting. The myocardial apoptosis rate was determined using the terminal deoxynucleotidyl transferase dUTP nick end labeling assay. Ischemia models with stenosis rates of 55 and 75% were successfully constructed following suturing of the descending artery. Compared with the control, the 55 and 75% stenosis groups demonstrated significantly decreased P1/P0, increased expression levels of TNF-α, cTnI, CK-MB, IL-6, IL-10 and caspase-3, an increased rate of myocardial apoptosis, and a decreased expression level of anti-apoptotic protein, Bcl-2. At 30 min following successful establishment of the model (ST segment elevation to 1 mm), group B demonstrated significantly increased P1/P0, decreased expression levels of TNF-α, cTnI, CK-MB, IL-6, IL-10 and caspase-3, a decreased rate of myocardial apoptosis, and an increased expression level of anti-apoptotic protein, Bcl-2. Furthermore, the current study indicated that active perfusion was more efficacious in maintaining myocardial perfusion and alleviating

  12. Myocardial perfusion imaging with thalium 201 during and after exercise in patients with coronary heart

    Energy Technology Data Exchange (ETDEWEB)

    Bravo, P B; Villacorta, E V; Monzon, O P; Torres, Jr, J F; Guzman, S V

    1977-07-01

    A unique, non-invasive technique for the evaluation of the regional myocardial perfusion of patients with coronary heart disease has been developed. This entails the use of radionuclide, like thallium (Tl-201), which concentrates in the normal myocardium, leaving areas of ischemia or scarring or ''cold'' perfusion defects. Myocardial perfusion imaging in conjunction with graded exercise testing significantly increases the positivity of the stress test alone among patients with classic angina from 80% to 95%. It gives invaluable information as to the site and extent of the lesion and its reversibility. Among the patients with ECG Q waves indicative of previous infarction, image defects were detected in 93.7%; reversible ischemia co-existing with the infarction was also demonstrated.

  13. Volume of myocardium perfused by coronary artery branches as estimated from 3D micro-CT images of rat hearts

    Science.gov (United States)

    Lund, Patricia E.; Naessens, Lauren C.; Seaman, Catherine A.; Reyes, Denise A.; Ritman, Erik L.

    2000-04-01

    Average myocardial perfusion is remarkably consistent throughout the heart wall under resting conditions and the velocity of blood flow is fairly reproducible from artery to artery. Based on these observations, and the fact that flow through an artery is the product of arterial cross-sectional area and blood flow velocity, we would expect the volume of myocardium perfused to be proportional to the cross-sectional area of the coronary artery perfusing that volume of myocardium. This relationship has been confirmed by others in pigs, dogs and humans. To test the body size-dependence of this relationship we used the hearts from rats, 3 through 25 weeks of age. The coronary arteries were infused with radiopaque microfil polymer and the hearts scanned in a micro- CT scanner. Using these 3D images we measured the volume of myocardium and the arterial cross-sectional area of the artery that perfused that volume of myocardium. The average constant of proportionality was found to be 0.15 +/- 0.08 cm3/mm2. Our data showed no statistically different estimates of the constant of proportionality in the rat hearts of different ages nor between the left and right coronary arteries. This constant is smaller than that observed in large animals and humans, but this difference is consistent with the body mass-dependence on metabolic rate.

  14. Cross-talk between cardiac muscle and coronary vasculature.

    Science.gov (United States)

    Westerhof, Nico; Boer, Christa; Lamberts, Regis R; Sipkema, Pieter

    2006-10-01

    The cardiac muscle and the coronary vasculature are in close proximity to each other, and a two-way interaction, called cross-talk, exists. Here we focus on the mechanical aspects of cross-talk including the role of the extracellular matrix. Cardiac muscle affects the coronary vasculature. In diastole, the effect of the cardiac muscle on the coronary vasculature depends on the (changes in) muscle length but appears to be small. In systole, coronary artery inflow is impeded, or even reversed, and venous outflow is augmented. These systolic effects are explained by two mechanisms. The waterfall model and the intramyocardial pump model are based on an intramyocardial pressure, assumed to be proportional to ventricular pressure. They explain the global effects of contraction on coronary flow and the effects of contraction in the layers of the heart wall. The varying elastance model, the muscle shortening and thickening model, and the vascular deformation model are based on direct contact between muscles and vessels. They predict global effects as well as differences on flow in layers and flow heterogeneity due to contraction. The relative contributions of these two mechanisms depend on the wall layer (epi- or endocardial) and type of contraction (isovolumic or shortening). Intramyocardial pressure results from (local) muscle contraction and to what extent the interstitial cavity contracts isovolumically. This explains why small arterioles and venules do not collapse in systole. Coronary vasculature affects the cardiac muscle. In diastole, at physiological ventricular volumes, an increase in coronary perfusion pressure increases ventricular stiffness, but the effect is small. In systole, there are two mechanisms by which coronary perfusion affects cardiac contractility. Increased perfusion pressure increases microvascular volume, thereby opening stretch-activated ion channels, resulting in an increased intracellular Ca2+ transient, which is followed by an increase in Ca

  15. Design and rationale of the MR-INFORM study: stress perfusion cardiovascular magnetic resonance imaging to guide the management of patients with stable coronary artery disease

    Directory of Open Access Journals (Sweden)

    Hussain Shazia T

    2012-09-01

    Full Text Available Abstract Background In patients with stable coronary artery disease (CAD, decisions regarding revascularisation are primarily driven by the severity and extent of coronary luminal stenoses as determined by invasive coronary angiography. More recently, revascularisation decisions based on invasive fractional flow reserve (FFR have shown improved event free survival. Cardiovascular magnetic resonance (CMR perfusion imaging has been shown to be non-inferior to nuclear perfusion imaging in a multi-centre setting and superior in a single centre trial. In addition, it is similar to invasively determined FFR and therefore has the potential to become the non-invasive test of choice to determine need for revascularisation. Trial design The MR-INFORM study is a prospective, multi-centre, randomised controlled non-inferiority, outcome trial. The objective is to compare the efficacy of two investigative strategies for the management of patients with suspected CAD. Patients presenting with stable angina are randomised into two groups: 1 The FFR-INFORMED group has subsequent management decisions guided by coronary angiography and fractional flow reserve measurements. 2 The MR-INFORMED group has decisions guided by stress perfusion CMR. The primary end-point will be the occurrence of major adverse cardiac events (death, myocardial infarction and repeat revascularisation at one year. Clinical trials.gov identifier NCT01236807. Conclusion MR INFORM will assess whether an initial strategy of CMR perfusion is non-inferior to invasive angiography supplemented by FFR measurements to guide the management of patients with stable coronary artery disease. Non-inferiority of CMR perfusion imaging to the current invasive reference standard (FFR would establish CMR perfusion imaging as an attractive non-invasive alternative to current diagnostic pathways.

  16. High coronary artery calcium score affects clinical outcome despite normal stress myocardial perfusion imaging and normal left ventricular ejection fraction

    DEFF Research Database (Denmark)

    Madsen, Claus Juul; Andersen, Kim F; Zerahn, Bo

    2013-01-01

    Normal myocardial perfusion imaging (MPI) indicates a low risk for cardiac death and new ischaemic events. However, the impact of normal MPI combined with a high coronary artery calcium score (CACS) is not clear. The aims of this study were to evaluate the risk of severely elevated CACS and to id......Normal myocardial perfusion imaging (MPI) indicates a low risk for cardiac death and new ischaemic events. However, the impact of normal MPI combined with a high coronary artery calcium score (CACS) is not clear. The aims of this study were to evaluate the risk of severely elevated CACS...

  17. Myocardial perfusion scintigraphy with technetium 99m-MIBI in the diagnosis of coronary artery disease in women

    International Nuclear Information System (INIS)

    Peix, C. Amalia; Chacon, Deylis; Llerena, Lorenzo; Torres, Maritza; Garcia, Ernesto Javier; Cabrera, Lazaro Omar

    2006-01-01

    The results of technetium 99 m - methoxy-isobutyl-isonitrile scintigraphy in a one-day protocol: rest - physical or combined stress bicycle plus endovenoous dipyridamole were compared with those of coronary angiography in 20 women referred for the evaluation of pre cordial pain and of the usefulness of myocardial perfusion scintigraphy. The uptake of the radio drug under stress and at rest varied from 93 + - 9 to 94 + - 7 % in the 204 segments with normal uptake under stress, from 67 He articulates it analyzes the reasons or utility of the employment of the radioactive iodine in the diagnosis and treatment of the thyroid affections + - 9 to 75 + - 17 % in the 89 with moderate reduction, and from 33 + - 9 to 64 + - 28 % in the 27 with severe reduction. The qualitative and quantitative uptake analyses coincided in 18 patients. The perfusion scintigraphy and the angiography agreed in 70 % of the patients. It was concluded that the myocardial perfusion scintigraphy with technetium 99 -MIBI contributes to the diagnosis of the coronary artery disease in women

  18. Evaluation of patients with coronary artery disease during exercise: the relation between extent of disease and perfusion deficit

    International Nuclear Information System (INIS)

    Hakki, A.H.; DePace, N.; Iskandrian, A.S.

    1984-01-01

    The purpose of this study was to assess the relation between the extent of coronary artery disease (CAD) and size of exercise-induced myocardial hypoperfusion in 79 patients with angiographically documented CAD. None of the patients had Q-wave myocardial infarction. Fifty patients had one-vessel disease, ten had two-vessel disease, and 19 patients had three-vessel or left main disease. From a scintigraphic functional standpoint, patients were classified into two groups: 28 patients (35%) had large perfusion defects and 51 patients (65%) had small defects. The size of the thallium-201 perfusion defect during exercise was assessed as the perimeter of the defect in each projection expressed as a percentage abnormality of the total left ventricular perimeter in that projection. The average abnormality from the three projections was used in the final analysis. Eleven patients with large defects (39%) had one-vessel disease and 12 patients with small defects (24%) had multivessel disease. Stepwise multivariate discriminate analysis identified the number of diseased vessels (F . 13.9), the change in systolic blood pressure from rest to exercise (F . 10.8), the exercise heart rate (F . 9.1), and exercise electrocardiographic response (F . 7.8) as significant associates of the size of the perfusion defect (predictive accuracy . 70%). We conclude that the size of hypoperfused myocardium during exercise is variable in patients with CAD. Discriminate analysis identified the extent of CAD, exercise heart rate, change in systolic pressure from rest to exercise, and exercise electrocardiographic response as significant associates of the size of the defect

  19. Diagnostic performance of dual-energy CT stress myocardial perfusion imaging: direct comparison with cardiovascular MRI.

    Science.gov (United States)

    Ko, Sung Min; Song, Meong Gun; Chee, Hyun Kun; Hwang, Hweung Kon; Feuchtner, Gudrun Maria; Min, James K

    2014-12-01

    The purpose of this study was to assess the diagnostic performance of stress perfusion dual-energy CT (DECT) and its incremental value when used with coronary CT angiography (CTA) for identifying hemodynamically significant coronary artery disease. One hundred patients with suspected or known coronary artery disease without chronic myocardial infarction detected with coronary CTA underwent stress perfusion DECT, stress cardiovascular perfusion MRI, and invasive coronary angiography (ICA). Stress perfusion DECT and cardiovascular stress perfusion MR images were used for detecting perfusion defects. Coronary CTA and ICA were evaluated in the detection of ≥50% coronary stenosis. The diagnostic performance of coronary CTA for detecting hemo-dynamically significant stenosis was assessed before and after stress perfusion DECT on a per-vessel basis with ICA and cardiovascular stress perfusion MRI as the reference standard. The performance of stress perfusion DECT compared with cardiovascular stress perfusion MRI on a per-vessel basis in the detection of perfusion defects was sensitivity, 89%; specificity, 74%; positive predictive value, 73%; negative predictive value, 90%. Per segment, these values were sensitivity, 76%; specificity, 80%; positive predictive value, 63%; and negative predictive value, 88%. Compared with ICA and cardiovascular stress perfusion MRI per vessel territory the sensitivity, specificity, positive predictive value, and negative predictive value of coronary CTA were 95%, 61%, 61%, and 95%. The values for stress perfusion DECT were 92%, 72%, 68%, and 94%. The values for coronary CTA and stress perfusion DECT were 88%, 79%, 73%, and 91%. The ROC AUC increased from 0.78 to 0.84 (p=0.02) with the use of coronary CTA and stress perfusion DECT compared with coronary CTA alone. Stress perfusion DECT plays a complementary role in enhancing the accuracy of coronary CTA for identifying hemodynamically significant coronary stenosis.

  20. Determinants of abnormal blood pressure response to exercise in coronary artery disease

    International Nuclear Information System (INIS)

    Hakki, A.H.; Munley, B.M.; Hadjimiltiades, S.; Meissner, M.D.; Iskandrian, A.S.

    1986-01-01

    This study assessed the determinants of exercise-induced abnormal systolic blood pressure (BP) response in 127 patients with documented coronary artery disease (CAD) who underwent exercise thallium-201 scintigraphy. Three types of systolic BP response to exercise were identified: an increase by more than 20 mm Hg (group I, n = 74); an increase by 20 mm Hg or less (group II, n = 36); and a decrease of at least 10 mm Hg (group III, n = 17). The 3 groups were not significantly different in age, gender or medications. The number of segments with perfusion defects was significantly higher in groups II and III than group I (group III, 2.9 +/- 1.5; group II, 2.9 +/- 2.1; and group I, 1.8 +/- 1.4, p = 0.009). Prior myocardial infarction, abnormal left ventricular ejection fraction, and multivessel CAD were more common in group III than in groups I and II. Stepwise discriminant analysis of 15 relevant clinical, angiographic and exercise scintigraphic descriptors showed that the number of thallium perfusion defects, abnormal LV ejection fraction at rest and multivessel CAD to be important predictors of hypotensive BP response. Multivariate analysis, however, showed that the number of thallium perfusion defects was the only important predictor of the hypotensive response. Thus, it is the functional significance of CAD assessed by the extent of thallium perfusion abnormalities rather than the extent of CAD or left ventricular dysfunction at rest that determines the systolic BP response to exercise

  1. Carotid artery disease and low cerebral perfusion pressure

    DEFF Research Database (Denmark)

    Schroeder, T; Utzon, N P; Aabech, J

    1990-01-01

    Direct internal carotid artery blood pressure measurements in patients undergoing carotid endarterectomy identified 49 patients, among 239 consecutive cases (21%), who had a reduction in perfusion pressure of 20% or more. The clinical history, objective findings and angiographic data were compared...

  2. Meta-Analysis of Stress Myocardial Perfusion Imaging

    Science.gov (United States)

    2017-06-06

    Coronary Disease; Echocardiography; Fractional Flow Reserve, Myocardial; Hemodynamics; Humans; Magnetic Resonance Imaging; Myocardial Perfusion Imaging; Perfusion; Predictive Value of Tests; Single Photon Emission Computed Tomography; Positron Emission Tomography; Multidetector Computed Tomography; Echocardiography, Stress; Coronary Angiography

  3. Non-invasive diagnostic workup of patients with suspected stable angina by combined computed tomography coronary angiography and magnetic resonance perfusion imaging

    International Nuclear Information System (INIS)

    Kirschbaum, S.W.; Nieman, K.; Springeling, T.

    2011-01-01

    The background of this study was to evaluate additional adenosine magnetic resonance perfusion (MRP) imaging in the diagnostic workup of patients with suspected stable angina with computed tomography coronary angiography (CTCA) as first-line diagnostic modality. Two hundred and thirty symptomatic patients (male, 52%; age, 56 year) with suspected stable angina underwent CTCA. In patients with a stenosis of >50% as visually assessed, MRP was performed and the quantitative myocardial perfusion reserve index (MPRI) was calculated. Coronary flow reserve (CFR) using invasive coronary flow measurements served as the standard of reference. CTCA showed non-significant coronary artery disease (CAD) in 151/230 (66%) patients and significant CAD in 79/230 patients (34%), of whom 50 subsequently underwent MRP and CFR. MRP showed reduced perfusion in 32 patients (64%), which was confirmed by CFR in 27 (84%). All 18 cases of normal MRP (36%) were confirmed by CFR. The positive likelihood ratio of MRP for the presence of functional significant disease in patients with a lesion on CTCA was 4.49 (95% confidence interval [CI] 2.12-9.99). The negative likelihood ratio was 0.05 (95% CI 0.01-0.34). CTCA as first-line diagnostic modality excluded coronary artery disease in a high percentage of patients referred for diagnostic workup of suspected stable angina. MRP made a significant contribution to the detection of functional significant lesions in patients with a positive CTCA. (author)

  4. Myocardial perfusion imaging with dual energy CT

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Kwang Nam [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiology, SMG-SNU Boramae Medical Center, Seoul (Korea, Republic of); De Cecco, Carlo N. [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Caruso, Damiano [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiological Sciences, Oncology and Pathology, University of Rome “Sapienza”, Rome (Italy); Tesche, Christian [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Cardiology and Intensive Care Medicine, Heart Center Munich-Bogenhausen, Munich (Germany); Spandorfer, Adam; Varga-Szemes, Akos [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC (United States)

    2016-10-15

    Highlights: • Stress dual-energy sCTMPI offers the possibility to directly detect the presence of myocardial perfusion defects. • Stress dual-energy sCTMPI allows differentiating between reversible and fixed myocardial perfusion defects. • The combination of coronary CT angiography and dual-energy sCTMPI can improve the ability of CT to detect hemodynamically relevant coronary artery disease. - Abstract: Dual-energy CT (DECT) enables simultaneous use of two different tube voltages, thus different x-ray absorption characteristics are acquired in the same anatomic location with two different X-ray spectra. The various DECT techniques allow material decomposition and mapping of the iodine distribution within the myocardium. Static dual-energy myocardial perfusion imaging (sCTMPI) using pharmacological stress agents demonstrate myocardial ischemia by single snapshot images of myocardial iodine distribution. sCTMPI gives incremental values to coronary artery stenosis detected on coronary CT angiography (CCTA) by showing consequent reversible or fixed myocardial perfusion defects. The comprehensive acquisition of CCTA and sCTMPI offers extensive morphological and functional evaluation of coronary artery disease. Recent studies have revealed that dual-energy sCTMPI shows promising diagnostic accuracy for the detection of hemodynamically significant coronary artery disease compared to single-photon emission computed tomography, invasive coronary angiography, and cardiac MRI. The aim of this review is to present currently available DECT techniques for static myocardial perfusion imaging and recent clinical applications and ongoing investigations.

  5. Impaired vascular sensitivity to nitric oxide in the coronary microvasculature after endotoxaemia

    OpenAIRE

    Bogle, Richard G; McLean, Peter G; Ahluwalia, Amrita; Vallance, Patrick

    2000-01-01

    The effects of endotoxaemia on coronary vasodilator responses to bradykinin (BK), sodium nitroprusside (SNP) and nicardipine were investigated in the rat isolated heart perfused at constant flow ex vivo.Dose-dependent reductions in coronary perfusion pressure reaching a maximum of 56±3 and 57±5 mmHg were observed for BK and SNP respectively. The BK response was biphasic, consisting of a rapid dilator response that was insensitive to NGnitro-L-arginine methyl ester (L-NAME, 0.1 mM) and a secon...

  6. Myocardial perfusion changes in patients irradiated for left-sided breast cancer and correlation with coronary artery distribution

    International Nuclear Information System (INIS)

    Lind, Pehr A.; Pagnanelli, Robert; Marks, Lawrence B.; Borges-Neto, Salvador; Hu, Caroline; Zhou, S.-M.; Light, Kim; Hardenbergh, Patricia H.

    2003-01-01

    Purpose: To evaluate postradiation regional heart perfusion changes with single photon emission tomography (SPECT) myocardial perfusion imaging in 69 patients treated with tangential photon beams radiation therapy (RT) for left-sided breast cancer. To correlate SPECT changes with percent irradiated left ventricle (LV) volume and risk factors for coronary artery disease (CAD). Methods and Materials: Rest SPECT of the LV was acquired pre-RT and at 6-month intervals post-RT. The extent of defects (%) with a severity > 1.5 standard deviations below the mean was quantitatively analyzed for the distributions of the left anterior descending (LAD) artery, left circumflex (LCX) artery, and right coronary artery (RCA) based on computer assisted polar map reconstruction (i.e., bull's-eye-view). Changes in perfusion were correlated with percent irradiated LV receiving > 25 Gy (range 0-32%). Data on patient- and treatment-related factors were collected prospectively (e.g., cardiac premorbidity, risk factors for CAD, chemotherapy, and hormonal treatment). Results: In the LAD distribution, there were increased perfusion defects at 6 months (median 11%; interquartile range 2-23) compared with baseline (median 5%; interquartile range 1-14) (p<0.001). There were no increases in perfusion defects in the LCX or RCA distributions. In multivariate analysis, the SPECT perfusion changes in the LAD distribution at 6 months were independently associated with percent irradiated LV (p<0.001), hormonal therapy (p=0.005), and pre-RT hypercholesterolemia (p=0.006). The SPECT defects in the LAD distribution at 12 and 18 months were not statistically different from those at 6 months. The perfusion defects in the LAD distribution were limited essentially to the regions of irradiated myocardium. Conclusion: Tangential photon beam RT in patients with left-sided breast cancer was associated with short-term SPECT defects in the vascular distribution corresponding to the radiation portals. Factors

  7. Diagnostic accuracy of combined coronary angiography and adenosine stress myocardial perfusion imaging using 320-detector computed tomography: pilot study

    International Nuclear Information System (INIS)

    Nasis, Arthur; Ko, Brian S.; Leung, Michael C.; Antonis, Paul R.; Wong, Dennis T.; Kyi, Leo; Cameron, James D.; Meredith, Ian T.; Seneviratne, Sujith K.; Nandurkar, Dee; Troupis, John M.

    2013-01-01

    To determine the diagnostic accuracy of combined 320-detector row computed tomography coronary angiography (CTA) and adenosine stress CT myocardial perfusion imaging (CTP) in detecting perfusion abnormalities caused by obstructive coronary artery disease (CAD). Twenty patients with suspected CAD who underwent initial investigation with single-photon-emission computed tomography myocardial perfusion imaging (SPECT-MPI) were recruited and underwent prospectively-gated 320-detector CTA/CTP and invasive angiography. Two blinded cardiologists evaluated invasive angiography images quantitatively (QCA). A blinded nuclear physician analysed SPECT-MPI images for fixed and reversible perfusion defects. Two blinded cardiologists assessed CTA/CTP studies qualitatively. Vessels/territories with both >50 % stenosis on QCA and corresponding perfusion defect on SPECT-MPI were defined as ischaemic and formed the reference standard. All patients completed the CTA/CTP protocol with diagnostic image quality. Of 60 vessels/territories, 17 (28 %) were ischaemic according to QCA/SPECT-MPI criteria. Sensitivity, specificity, PPV, NPV and area under the ROC curve for CTA/CTP was 94 %, 98 %, 94 %, 98 % and 0.96 (P < 0.001) on a per-vessel/territory basis. Mean CTA/CTP radiation dose was 9.2 ± 7.4 mSv compared with 13.2 ± 2.2 mSv for SPECT-MPI (P < 0.001). Combined 320-detector CTA/CTP is accurate in identifying obstructive CAD causing perfusion abnormalities compared with combined QCA/SPECT-MPI, achieved with lower radiation dose than SPECT-MPI. (orig.)

  8. Diagnostic accuracy of combined coronary angiography and adenosine stress myocardial perfusion imaging using 320-detector computed tomography: pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Nasis, Arthur; Ko, Brian S.; Leung, Michael C.; Antonis, Paul R.; Wong, Dennis T.; Kyi, Leo; Cameron, James D.; Meredith, Ian T.; Seneviratne, Sujith K. [Southern Health and Monash University, Monash Cardiovascular Research Centre, Monash Heart, Department of Medicine Monash Medical Centre (MMC), Melbourne (Australia); Nandurkar, Dee; Troupis, John M. [MMC, Southern Health, Department of Diagnostic Imaging, Melbourne (Australia)

    2013-07-15

    To determine the diagnostic accuracy of combined 320-detector row computed tomography coronary angiography (CTA) and adenosine stress CT myocardial perfusion imaging (CTP) in detecting perfusion abnormalities caused by obstructive coronary artery disease (CAD). Twenty patients with suspected CAD who underwent initial investigation with single-photon-emission computed tomography myocardial perfusion imaging (SPECT-MPI) were recruited and underwent prospectively-gated 320-detector CTA/CTP and invasive angiography. Two blinded cardiologists evaluated invasive angiography images quantitatively (QCA). A blinded nuclear physician analysed SPECT-MPI images for fixed and reversible perfusion defects. Two blinded cardiologists assessed CTA/CTP studies qualitatively. Vessels/territories with both >50 % stenosis on QCA and corresponding perfusion defect on SPECT-MPI were defined as ischaemic and formed the reference standard. All patients completed the CTA/CTP protocol with diagnostic image quality. Of 60 vessels/territories, 17 (28 %) were ischaemic according to QCA/SPECT-MPI criteria. Sensitivity, specificity, PPV, NPV and area under the ROC curve for CTA/CTP was 94 %, 98 %, 94 %, 98 % and 0.96 (P < 0.001) on a per-vessel/territory basis. Mean CTA/CTP radiation dose was 9.2 {+-} 7.4 mSv compared with 13.2 {+-} 2.2 mSv for SPECT-MPI (P < 0.001). Combined 320-detector CTA/CTP is accurate in identifying obstructive CAD causing perfusion abnormalities compared with combined QCA/SPECT-MPI, achieved with lower radiation dose than SPECT-MPI. (orig.)

  9. Prognostic value of combined CT angiography and myocardial perfusion imaging versus invasive coronary angiography and nuclear stress perfusion imaging in the prediction of major adverse cardiovascular events

    DEFF Research Database (Denmark)

    Chen, Marcus Y.; Rochitte, Carlos E.; Arbab-Zadeh, Armin

    2017-01-01

    Purpose: To compare the prognostic importance (time to major adverse cardiovascular event [MACE]) of combined computed tomography (CT) angiography and CT myocardial stress perfusion imaging with that of combined invasive coronary angiography (ICA) and stress single photon emission CT myocardial p...

  10. Role of myocardial perfusion imaging in acute coronary syndrome

    International Nuclear Information System (INIS)

    Aleem, M.

    2007-01-01

    Full text: In the cardiac emergency department, a number of patients present with acute chest pain. In case of non diagnostic ECG and enzymes, accurately categorizing the patient in high and low probability is difficult. Aim of study was to evaluate the role of resting myocardial perfusion imaging (MPI) in patients with acute coronary syndrome (ACS) and then to compare the results with subsequent stress imaging. Material and Methods. A total of 34 patients were selected for the study, which were divided into three groups on the basis of respective probabilities of having ACS. This probability was decided on the basis of nature of chest pain, ECG findings, enzymes levels, and age and sex. Arbitrary score was given to patient's condition. This score ranged from 1 to 14. Patients with score between 1-6 were assigned low probability, from 7-10 were assigned intermediate probability and patients having score greater than 11 were placed in high probability groups. Patients in the low and intermediate probability groups were injected with Tc 99 m- MIBI within 6 hours of onset of chest pain and were undergone resting myocardial perfusion imaging (MPI) 3 to five hours after injection.. Imaging in high probability group was performed at discharge. Four weeks after the acute event all the patients underwent stress myocardial perfusion imaging. Results: All patients (100%) with low probability of ACS (n=10) showed negative resting scans. On stress MPI two patients (20%) showed new defects. Patient with high probability of ACS (n=12), all were positive 100% on resting MPI. On stress MPI, three showed (25%) no change from rest MPI, while nine patients (75%) showed augmentation of defects and four out of these nine patients (33%) also showed new perfusion defects. Patients with intermediate probability of ACS (n=12), three showed positive rest MPI (25%). On stress MPI out of these three cases, one showed (8%) no change from rest MPI and two showed (17%) augmentation of defect

  11. Myocardial performance and perfusion during exercise in patients with coronary artery disease caused by Kawasaki disease

    International Nuclear Information System (INIS)

    Paridon, S.M.; Ross, R.D.; Kuhns, L.R.; Pinsky, W.W.

    1990-01-01

    For a study of the natural history of coronary artery lesions after Kawasaki disease and their effect on myocardial blood flow reserve with exercise, five such patients underwent exercise testing on a bicycle. Oxygen consumption, carbon dioxide production, minute ventilation, and electrocardiograms were monitored continuously. Thallium-201 scintigraphy was performed for all patients. One patient stopped exercise before exhaustion of cardiovascular reserve but had no evidence of myocardial perfusion abnormalities. Four patients terminated exercise because of exhaustion of cardiovascular reserve; one had normal cardiovascular reserve and thallium scintiscans, but the remaining patients had diminished cardiovascular reserve. Thallium scintigrams showed myocardial ischemia in two and infarction in one. No patient had exercise-induced electrocardiographic changes. These results indicate that patients with residual coronary artery lesions after Kawasaki disease frequently have reduced cardiovascular reserve during exercise. The addition of thallium scintigraphy and metabolic measurements to exercise testing improved the detection of exercise-induced abnormalities of myocardial perfusion

  12. Inhibition of coronary blood flow by a vascular waterfall mechanism.

    Science.gov (United States)

    Downey, J M; Kirk, E S

    1975-06-01

    The mechanism whereby systole inhibits coronary blood flow was examined. A branch of the left coronary artery was maximally dilated with an adenosine infusion, and the pressure-flow relationship was obtained for beating and arrested states. The pressure-flow curve for the arrested state was shifted toward higher pressures and in the range of pressures above peak ventricular pressure was linear and parallel to that for the arrested state. Below this range the curve for the beating state converged toward that for the arrested state and was convex to the pressure axis. These results were compared with a model of the coronary vasculature that consisted of numerous parallel channels, each responding to local intramyocardial pressure by forming vascular waterfalls. When intramyocardial pressure in the model was assigned values from zero at the epicardium to peak ventricular pressure at the endocardium, pressure-flow curves similar to the experimental ones resulted. Thus, we conclude that systole inhibits coronary perfusion by the formation of vascular waterfalls and that the intramyocardial pressures responsible for this inhibition do not significantly exceed peak ventricular pressure.

  13. Comparison of adenosine stress and exercise stress 201Tl myocardial perfusion imaging for diagnosis of coronary heart disease

    International Nuclear Information System (INIS)

    Chen Guibing; Wu Hua; Jiang Ningyi; Liu Sheng; Lu Xianping; Liang Jiugen; Zhang Hong

    2007-01-01

    Objective: The aim of this study was to compare the diagnostic values of adenosine and exercise stress 201 Tl myocardial perfusion imaging for detecting coronary heart disease (CHD). Methods: 41 patients with suspected CHD were randomly divided into two groups. In one group adenosine stress was submitted, the exercise stress myocardial SPECT was performed in another. Coronary angiography (CAG) was performed in each patient within 2 weeks before or after SPECT. The result of CAG was taken as 'gold standard of CHD. They compared the diagnostic value of two methods. Results: In adenosine group, the sensitivity, specificity, positive predictive value, negative predictive value, accuracy are 92.86%, 57.14%, 81.25%, 80.00%, 80.95% respectively. In exercise stress group, are 100%, 60.0%, 71.43%, 100%, 80.00% respectively. Detection rates of coronary artery lesions were 66.67% and 72.22% in two groups respectively. Conclusion Adenosine stress testing and exercise stress testing 201 Tl myocardial perfusion imaging may provide similar value for detection of CHD. (authors)

  14. The Myocardial Perfusion Scintigraphy in Predicting Risk for Coronary Artery Disease in Patients with Anxiety and Depression Symptoms

    Directory of Open Access Journals (Sweden)

    Billur Çalışkan

    2016-06-01

    Full Text Available INTRODUCTION: An association between psychological factors and cardiovascular disease, has long been suspected. However it is not clear whether chest pain is caused by emotional distress or whether coronary spasms are caused by the onset of coronary artery disease (CAD. We aimed to predict the risk for CAD in patients referred to myocardial perfusion imaging (MPI with chest pain using depression, stress, and anxiety symptoms. METHODS: The emotional status of all patients was evaluated using the Hospital Anxiety and Depression Scale (HADS-A and HADS-D, the State and Trait Anxiety Inventory (STAI-1 and STAI-2, the Perceived Stress Scale (PSS, and the Anxiety Sensitivity Index-3 (ASI. Myocardial perfusion was measured using a 17-segment model and 5-point scoring system (0: normal perfusion; 4: no perfusion. RESULTS: MPI revealed reversible perfusion defects in 24 of 141 patients and no perfusion defects in 117 patients. The STAI-2 and HADS-A and HADS-D scores were significantly higher in patients with myocardial ischemia than in those without (STAI-2: 50.8 ± 7.5 vs. 46.3 ± 7.1, respectively; p = 0.008; HADS-A: 9.5 ± 3.9 vs. 7.8 ± 3.4, respectively; p = 0.033; HADS-D: 8.7 ± 3.0 vs. 7.3 ± 3.0, respectively; p = 0.05. Unadjusted correlation analysis showed that there was statistically significant correlation between reversible perfusion defects and anxiety scores (r=0.186, p= 0.029. DISCUSSION AND CONCLUSION: The patients with symptoms of depression and high-trait anxiety may be at higher risk of myocardial ischemia than patients without such symptoms. Thus, the emotional status of patients should be taken into consideration during clinical evaluation for CAD.

  15. Relationships of elevated systemic pentraxin-3 levels with high-risk coronary plaque components and impaired myocardial perfusion after percutaneous coronary intervention in patients with ST-elevation acute myocardial infarction.

    Science.gov (United States)

    Kimura, Shigeki; Inagaki, Hiroshi; Haraguchi, Go; Sugiyama, Tomoyo; Miyazaki, Toru; Hatano, Yu; Yoshikawa, Shunji; Ashikaga, Takashi; Isobe, Mitsuaki

    2014-01-01

    We aimed to assess the relationships of pentraxin-3 (PTX3) with coronary plaque components and myocardial perfusion after percutaneous coronary intervention (PCI) in order to clarify the mechanisms underlying the prognostic function of PTX3 in ST-elevation acute myocardial infarction (STEMI) patients. We enrolled 75 STEMI patients who underwent pre-PCI virtual histology (VH)-intravascular ultrasound. Relationships of the systemic pre-PCI PTX3 level with coronary plaque components and post-PCI myocardial blush grade (MBG) were evaluated. Lesions with elevated pre-PCI PTX3 (median ≥3.79ng/ml) had higher frequencies of VH-derived thin-cap fibroatheroma (65.8% vs. 24.3%, P2 on admission (hazard ratio, 5.356; 95% CI, 1.409-20.359; P=0.014) as independent predictors of adverse cardiac events during follow-up. Systemic pre-PCI PTX3 was associated with high-risk plaque components and impaired post-PCI myocardial perfusion. Thus, PTX3 may be a reliable predictor of outcome in STEMI patients.

  16. [Experimental evaluation of the role of the coronary sinus pressure in the regulation of coronary return volume via the coronary sinus. Surgical considerations in atrio-pulmonary diversion procedures].

    Science.gov (United States)

    Fantidis, P; Fernández Ruiz, M A; Madero Jarabo, R; Moreno Granados, F; Cordovilla Zurdo, G; Sanz Galeote, E

    1990-11-01

    In order to find out the validity of the vascular waterfall mechanism in coronary venous circulation, the role of coronary sinus pressure in the regulation of coronary return volume via the coronary sinus is studied in healthy animals. An experimental model of pressure regulation in the coronary sinus was prepared, and aortic pressure, EKG and the cardiac output (measured by thermodilution) were recorded. The return volume via the coronary sinus was measured at coronary sinus pressure of 10 or less, 15, 20, and 25 mmHg or more, for a total of 36 determinations. Increased coronary sinus pressure did not produce significant changes in aortic pressure, heart rate, cardiac index or coronary return volume via coronary sinus. When coronary sinus pressure was 25 mmHg or more, there was a significant decline in the average of coronary return volume via coronary sinus. Nevertheless, stepwise variant regression showed that the coronary sinus pressure per se does not condition the volume of coronary return via the coronary sinus. Our results suggest that in the healthy animals, the vascular waterfall mechanism in coronary venous circulation is not valid. Our results suggest that in the correction of congenital cardiac malformations using atriopulmonary anastomosis procedures, employing techniques that ensure coronary sinus drainage into the left atrium, in order to avoid the hemodynamic repercussions attributable to the vascular waterfall mechanism, is not justified.

  17. Assessment of the myocardial perfusion pattern in patients with multivessel coronary artery disease

    International Nuclear Information System (INIS)

    Iskandrian, A.S.; Hakki, A.H.; Segal, B.L.; Kane, S.A.; Amenta, A.

    1983-01-01

    A total of 42 symptomatic patients with coronary artery disease involving two or three vessels were studied using exercise thallium-201 myocardial scintigraphy. Qualitative analysis of the images predicted multivessel disease in 75% of the patients with two-vessel disease and in 82% of the patients with three-vessel disease. Quantitative analysis of the size of the perfusion defect indicated that approximately 40% of the left ventricular perimeter showed abnormal perfusion pattern during stress in these patients, and there was no significant difference in the size of the defect in patients with two-vessel disease or three-vessel disease (41 +/- 17% vs 42 +/- 14%, respectively, mean +/- SD). The exercise heart rate, exercise ECG response, and severity of narrowing did not correlate with the size of the perfusion defect. Patients with anterior infarction had larger defects in the distribution of the left anterior descending artery than those without infarction. Collaterals offered partial protection during exercise only when they were not jeopardized. This study confirms the value of qualitative analysis of exercise thallium-201 imaging in predicting multivessel disease, and describes a simple method of assessing the extent of perfusion abnormalities during stress in patients with multivessel disease. The results may be important in patient management and prognosis

  18. Hypothermic Machine Perfusion of Kidney Grafts: Which Pressure is Preferred?

    NARCIS (Netherlands)

    Doorschodt, B. M.; Schreinemachers, M. C. J. M.; Behbahani, M.; Florquin, S.; Weis, J.; Staat, M.; Tolba, R. H.

    2011-01-01

    To assess the effect of the perfusion pressure (PP) during machine perfusion (MP) on the preservation quality of kidney grafts, we compared mean PPs of 25 and 30 mmHg using a porcine autotransplantation model. After assessment of the microcirculation, animals underwent left nephrectomy. Thereafter,

  19. Thallium-201 exercise myocardial imaging to evaluate myocardial perfusion after coronary artery bypass surgery

    International Nuclear Information System (INIS)

    Hirzel, H.O.; Nuesch, K.; Sialer, G.; Horst, W.; Krayenbuehl, H.P.

    1980-01-01

    To assess the usefulness of thallium-201 exercise scintigraphy in evaluating myocardial perfusion after coronary artery bypass surgery, imaging was performed after submaximal bicycle ergometry and at rest in 54 patients before and within 24 +- 10 (SD) weeks after operation. Scintigraphy identified 8 out of 20 patients who were symptom free after operation and showed normal exercise electrocardiograms as still having exercise-induced ischaemia and thus as having not truly benefited from the surgical intervention. In contrast, improvement in perfusion was documented in 17 out of 31 patients despite further complaints of chest pain and persistence of a pathological exercise electrocardiogram in 6 of them. Bypass graft patency rate paralleled the scintigraphic findings in the 35 patients who were restudied arteriographically. It was concluded that thallium-201 exercise scintigraphy is a useful technique to document changes in regional perfusion after surgery and is definitely superior to the clinical evaluation of patients including the exercise electrocardiogram. (author)

  20. Evaluation of full time and half time acquired cardiac perfusion images and its correlation with coronary angiography

    International Nuclear Information System (INIS)

    Madhusudhanan, P.; Kapoor, A.; Arya, A.; Ora, M.; Kheruka, S.; Dube, V.; Uttam Kumar; Verma, R.S.; Singh, R.D.; Gambhir, S.

    2010-01-01

    Full text: The myocardial perfusion study takes a longer time to complete. A reduction in acquisition time would mean reduced patient motion related artifacts, improvement in camera efficiency and reduction in cost. Iterative reconstruction algorithms produce more accurate images with fewer artifacts. Materials and Methods: Seventy three patients undergoing myocardial perfusion imaging were selected for additional half time acquisition. Patients with suspected or known coronary artery disease who have undergone coronary angiography recently were preferably included. Images were analysed in 4 groups - full time FBP, half time FBP, half time OSEM and half time OSEM. Three independent observers blinded to the clinical data and the acquisition protocol analysed images for change in image quality between these groups. Semiquantitative parameters of summed stress score, summed rest score, summed difference score and left ventricular ejection fraction were also compared using appropriate statistical methods. Results: No difference was noted in SSS, SRS, SDS and LVEF calculated for full time and half time. However, significant difference was found between SSS, SRS and SDS calculated for FBP and OSEM processed half time studies and no significant difference for LVEF calculated for these two groups. Significant change in image quality was noted by 2 observers only in 1.4% and 2.7% of cases. A true positivity rate of 88% was seen in comparison with coronary angiography. Conclusion: Gated myocardial perfusion SPECT images acquired in half the routine scan time provides equal diagnostic information compared to a conventional full time study, regardless of the processing protocol

  1. Magnetic resonance myocardial perfusion imaging-First experience at 3.0 T

    Energy Technology Data Exchange (ETDEWEB)

    Klumpp, B. [Eberhard-Karls-University Tuebingen, University Hospital Tuebingen, Department of Diagnostic Radiology, Hoppe-Seyler-Str. 3, 72076 Tuebingen (Germany)], E-mail: bernhard.klumpp@med.uni-tuebingen.de; Hoevelborn, T. [Eberhard-Karls-University Tuebingen, University Hospital Tuebingen, Department of Cardiology, Otfried-Mueller-Str. 10, 72076 Tuebingen (Germany)], E-mail: tobias.hoevelborn@gmx.de; Fenchel, M. [Eberhard-Karls-University Tuebingen, University Hospital Tuebingen, Department of Diagnostic Radiology, Hoppe-Seyler-Str. 3, 72076 Tuebingen (Germany)], E-mail: michael.fenchel@med.uni-tuebingen.de; Stauder, N.I. [Eberhard-Karls-University Tuebingen, University Hospital Tuebingen, Department of Diagnostic Radiology, Hoppe-Seyler-Str. 3, 72076 Tuebingen (Germany)], E-mail: norbert.stauder@stgag.ch; Kramer, U. [Eberhard-Karls-University Tuebingen, University Hospital Tuebingen, Department of Diagnostic Radiology, Hoppe-Seyler-Str. 3, 72076 Tuebingen (Germany)], E-mail: ulrich.kramer@med.uni-tuebingen.de; May, A. [Eberhard-Karls-University Tuebingen, University Hospital Tuebingen, Department of Cardiology, Otfried-Mueller-Str. 10, 72076 Tuebingen (Germany)], E-mail: andreas.may@med.uni-tuebingen.de; Gawaz, M.P. [Eberhard-Karls-University Tuebingen, University Hospital Tuebingen, Department of Cardiology, Otfried-Mueller-Str. 10, 72076 Tuebingen (Germany)], E-mail: meinrad.gawaz@med.uni-tuebingen.de; Claussen, C.D. [Eberhard-Karls-University Tuebingen, University Hospital Tuebingen, Department of Diagnostic Radiology, Hoppe-Seyler-Str. 3, 72076 Tuebingen (Germany)], E-mail: claus.claussen@med.uni-tuebingen.de; Miller, S. [Eberhard-Karls-University Tuebingen, University Hospital Tuebingen, Department of Diagnostic Radiology, Hoppe-Seyler-Str. 3, 72076 Tuebingen (Germany)], E-mail: stephan.miller@med.uni-tuebingen.de

    2009-01-15

    Objective: MR myocardial perfusion imaging (MRMPI) is an established technique for the evaluation of the hemodynamical relevance of coronary artery disease. Perfusion imaging at 3.0 T provides certain advantages compared to 1.5 T. Aim of this study was to evaluate myocardial MR perfusion imaging at 3.0 T. Materials and methods: Twelve patients with stable Angina pectoris and known or suspected coronary artery disease were examined at 3.0 T. Myocardial perfusion was assessed using a saturation recovery gradient echo 2D sequence (TR 1.9 ms, TE 1.0 ms, FA 12 deg.) with 0.05 mmol Gd-DTPA per kg body weight at stress during injection of 140 {mu}g adenosine/kg body weight/min and at rest in short axis orientation. Perfusion analysis was based on a least square fit of the signal/time curve (peak signal intensity, slope). Perfusion series were assessed by two independent observers. Reference for the presence of relevant coronary artery stenoses was invasive coronary angiography. Two experienced observers evaluated the coronary angiograms in biplane projections for the presence and grade of stenoses. Results were compared with the MR perfusion analysis. Results: All MR examinations could be safely performed and yielded high image quality. In eight patients stress-induced hypoperfusion was detected (stenosis >70% in coronary angiography). In four patients myocardial hypoperfusion was ruled out (stenosis <70%). The myocardial perfusion reserve index was significantly reduced in hypoperfused myocardium with 1.9 {+-} 1.6 compared to 2.5 {+-} 1.6 in regularly perfused myocardium (p < 0.05). In coronary angiography, eight patients were found to suffer from coronary artery disease, whereas in four patients coronary artery disease was ruled out. Conclusion: Our initial results show that MRMPI at 3.0 T provides reliably high-image quality and diagnostic accuracy.

  2. Abnormal perfusion on myocardial perfusion SPECT in patients with Wolff-Parkinson-White syndrome

    International Nuclear Information System (INIS)

    Kang, Do Young; Cha, Kwang Soo; Han, Seung Ho; Park, Tae Ho; Kim, Moo Hyun; Kim, Young Dae

    2005-01-01

    Abnormal myocardial perfusion may be caused by ventricular preexcitation, but its location, extent, severity and correlation with accessory pathway (AP) are not established. We evaluated perfusion patterns on myocardial perfusion SPECT and location of AP in patients with WPW (Wolff-Parkison-White) syndrome. Adenosine Tc-99m MIBI or Tl-201 myocardial perfusion SPECT was performed in 11 patients with WPW syndrome. Perfusion defects (PD) were compared to AP location based on ECT with Fitzpatrick's algorithm of electrophysiologic study and radiofrequency catheter ablation. Patients had atypical chest discomfort or no symptom. Risk of coronary artery disease (CAD) was below 0.1 in 11 patients using the nomogram to estimate the probability of CAD. Coronary angiography was performed in 4 patients(mid-LAD 50% in one, normal in others). In 4 patients, AP localization was done by electrophysiologic study and radiofrequency catheter ablation (RFCA). Small to large extent (11.0 ± 8.5%, range:3 ∼ 35%) and mild to moderate severity (-71 ± 42.7%, range:-217 ∼ -39%) of reversible (n=9) or fixed (n=1) perfusion defects were noted. One patients with right free wall (right lateral) AP showed normal. PD locations were variable following the location of AP. One patient with left lateral wall AP was followed 6 weeks after RFCA and showed significantly decreased PD on SPECT with successful ablation. Myocardial perfusion defect showed variable extent, severity and location in patients with WPW syndrome. Abnormal perfusion defect showed in most of all patients, but if did not seem to be correlated specifically with location of accessory pathway and coronary artery disease. Therefore myocardial perfusion SPECT should be interpreted carefully in patients with WPW syndrome

  3. Abnormal perfusion on myocardial perfusion SPECT in patients with Wolff-Parkinson-White syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Do Young; Cha, Kwang Soo; Han, Seung Ho; Park, Tae Ho; Kim, Moo Hyun; Kim, Young Dae [Donga University College of Medicine, Busan (Korea, Republic of)

    2005-02-15

    Abnormal myocardial perfusion may be caused by ventricular preexcitation, but its location, extent, severity and correlation with accessory pathway (AP) are not established. We evaluated perfusion patterns on myocardial perfusion SPECT and location of AP in patients with WPW (Wolff-Parkison-White) syndrome. Adenosine Tc-99m MIBI or Tl-201 myocardial perfusion SPECT was performed in 11 patients with WPW syndrome. Perfusion defects (PD) were compared to AP location based on ECT with Fitzpatrick's algorithm of electrophysiologic study and radiofrequency catheter ablation. Patients had atypical chest discomfort or no symptom. Risk of coronary artery disease (CAD) was below 0.1 in 11 patients using the nomogram to estimate the probability of CAD. Coronary angiography was performed in 4 patients(mid-LAD 50% in one, normal in others). In 4 patients, AP localization was done by electrophysiologic study and radiofrequency catheter ablation (RFCA). Small to large extent (11.0 {+-} 8.5%, range:3 {approx} 35%) and mild to moderate severity (-71 {+-} 42.7%, range:-217 {approx} -39%) of reversible (n=9) or fixed (n=1) perfusion defects were noted. One patients with right free wall (right lateral) AP showed normal. PD locations were variable following the location of AP. One patient with left lateral wall AP was followed 6 weeks after RFCA and showed significantly decreased PD on SPECT with successful ablation. Myocardial perfusion defect showed variable extent, severity and location in patients with WPW syndrome. Abnormal perfusion defect showed in most of all patients, but if did not seem to be correlated specifically with location of accessory pathway and coronary artery disease. Therefore myocardial perfusion SPECT should be interpreted carefully in patients with WPW syndrome.

  4. Effects of Constant Flow vs. Constant Pressure Perfusion on Fluid Filtration in Severe Hypothermic Isolated Blood-Perfused Rat Lungs.

    Science.gov (United States)

    Halsøy, Kathrine; Kondratiev, Timofey; Tveita, Torkjel; Bjertnaes, Lars J

    2016-01-01

    Victims of severe accidental hypothermia are prone to fluid extravasation but rarely develop lung edema. We hypothesize that combined hypothermia-induced increase in pulmonary vascular resistance (PVR) and a concomitant fall in cardiac output protect the lungs against edema development. Our aim was to explore in hypothermic-isolated blood-perfused rat lungs whether perfusion at constant pressure influences fluid filtration differently from perfusion at constant flow. Isolated blood-perfused rat lungs were hanging freely in a weight transducer for measuring weight changes (ΔW). Fluid filtration coefficient (Kfc), was determined by transiently elevating left atrial pressure (Pla) by 5.8 mmHg two times each during normothermia (37°C) and during hypothermia (15°C). The lung preparations were randomized to two groups. One group was perfused with constant flow (Constant flow group) and the other group with constant pulmonary artery pressure (Constant PPA group). Microvascular pressure (Pmv) was determined before and during elevation of Pla (ΔPmv) by means of the double occlusion technique. Kfc was calculated with the formula Kfc = ΔW/ΔPmv/min. All Kfc values were normalized to predicted lung weight (P LW ), which was based on body weight (BW) according to the formula: P LW  = 0.0053 BW - 0.48 and presented as Kfc PLW in mg/min/mmHg/g. At cessation, bronchoalveolar lavage (BAL) fluid/perfusate protein concentration (B/P) ratio was determined photometrically. Data were analyzed with parametric or non-parametric tests as appropriate. p  Kfc PLW and B/P ratio increased significantly by more than 10-fold during hypothermia concerted by visible signs of edema in the trachea. Hemoglobin and hematocrit increased within the Constant flow group and between the groups at cessation of the experiments. In hypothermic rat lungs perfused at constant flow, fluid filtration coefficient per gram P LW and B/P ratio increased more than 10-fold concerted by increased

  5. The accuracy of myocardial perfusion SPECT imaging in the evaluation of coronary artery disease in women and men

    International Nuclear Information System (INIS)

    Kaminek, M.; Myslivecek, M.; Huyak, V.; Koranda, P.; Skvarilova, M.; Ostransky, J.

    2001-01-01

    The purpose of this study is to compare sensitivity, specificity and accuracy of myocardial perfusion SPECT for the detection of coronary artery disease (CAD) in women and men. 588 patients (455 males and 133 females, 273 after a previous myocardial infarction) underwent stress myocardial perfusion SPECT. The accuracy of myocardial perfusion SPECT was proved by coronary angiography (stenosis >50% was considered as a CAD). The sensitivity of SPECT was slightly higher, but statistically not significant, in men than in women (94% versus 91%, p > 0.05). The specificity was higher in women than in men (93% versus 82%), but this difference was not statistically significant either (p > 0.05). The accuracy of SPECT was the same for both sexes (92%). In angiographically verified group of patients the selection bias was obvious - patients with CAD dominated (74%) and the fraction of patients with CAD in men's group (83%) was significantly higher than in women's group (50%), p < 0.05. No significant difference was revealed in the accuracy of myocardial perfusion SPECT in men and women. Our results are in accordance with the prevailing opinion in literature that discovered differences in sensitivity, specificity and diagnostic accuracy are usually not statistically significant or that they can be explained by the selection bias of patients in angiographically verified groups (significantly higher fraction of patients with CAD in men's group). (author)

  6. Low pulmonary artery flush perfusion pressure combined with high positive end-expiratory pressure reduces oedema formation in isolated porcine lungs

    International Nuclear Information System (INIS)

    Schumann, Stefan; Schließmann, Stephan J; Wagner, Giskard; Goebel, Ulrich; Priebe, Hans-Joachim; Guttmann, Josef; Kirschbaum, Andreas

    2010-01-01

    Flush perfusion of the pulmonary artery with organ protection solution is a standard procedure before lung explantation. However, rapid flush perfusion may cause pulmonary oedema which is deleterious in the lung transplantation setting. In this study we tested the hypotheses that high pulmonary perfusion pressure contributes to the development of pulmonary oedema and positive end-expiratory pressure (PEEP) counteracts oedema formation. We expected oedema formation to increase weight and decrease compliance of the lungs on the basis of a decrease in alveolar volume as fluid replaces alveolar air spaces. The pulmonary artery of 28 isolated porcine lungs was perfused with a low-potassium dextrane solution at low (mean 27 mmHg) or high (mean 40 mmHg) pulmonary artery pressure (PAP) during mechanical ventilation at low (4 cmH 2 O) or high (8 cmH 2 O) PEEP, respectively. Following perfusion and storage, relative increases in lung weight were smaller (p < 0.05) during perfusion at low PAP (62 ± 32% and 42 ± 26%, respectively) compared to perfusion at high PAP (133 ± 54% and 87 ± 30%, respectively). Compared to all other PAP–PEEP combinations, increases in lung weight were smallest (44 ± 9% and 27 ± 12%, respectively), nonlinear intratidal lung compliance was largest (46% and 17% respectively, both p < 0.05) and lung histology showed least infiltration of mononuclear cells in the alveolar septa, and least alveolar destruction during the combination of low perfusion pressure and high PEEP. The findings suggest that oedema formation during pulmonary artery flush perfusion in isolated and ventilated lungs can be reduced by choosing low perfusion pressure and high PEEP. PAP–PEEP titration to minimize pulmonary oedema should be based on lung mechanics and PAP monitoring

  7. Diagnostic value of transesophageal atrial pacing myocardial perfusion imaging in coronary artery disease

    International Nuclear Information System (INIS)

    Jia Yongping; Li Zhiling; Li Yunqian

    1994-01-01

    Transesophageal atrial pacing (TAP) SPECT myocardial perfusion imaging (MPI) with 99m Tc-MIBI was performed in 46 patients with coronary artery disease (CAD) and 15 normal subjects. The results were compared with exercise SPECT MPI. The results showed that the sensitivity and specificity of TAP SPECT to evaluate CAD were 86,96% and 93.33%. TAP SPECT MPI had a significant correlation with exercise SPECT MPI to detect ischemic segment of CAD (r = 0.95)

  8. Dynamic CT myocardial perfusion imaging identifies early perfusion abnormalities in diabetes and hypertension : Insights from a multicenter registry

    NARCIS (Netherlands)

    Vliegenthart, Rozemarijn; De Cecco, Carlo N.; Wichmann, Julian L.; Meinel, Felix G.; Pelgrim, Gert Jan; Tesche, Christian; Ebersberger, Ullrich; Pugliese, Francesca; Bamberg, Fabian; Choe, Yeon Hyeon; Wang, Yining; Schoepf, U. Joseph

    2016-01-01

    Background: To identify patients with early signs of myocardial perfusion reduction, a reference base for perfusion measures is needed. Objective: To analyze perfusion parameters derived from dynamic computed tomography perfusion imaging (CTPI) in patients with suspected coronary artery disease

  9. Improved assessment of functional severity of coronary artery stenosis by analysis of combined intracoronary pressure and flow velocity signals

    NARCIS (Netherlands)

    Nolte, F.

    2014-01-01

    Coronary artery disease (CAD) accounts for almost 2 million deaths per year within the EU. CAD is often characterized by focal narrowing of epicardial arteries, limiting coronary arterial flow and myocardial perfusion. Treatment of critical lesions by percutaneous coronary intervention (PCI) can be

  10. Initial intramuscular perfusion pressure predicts early skeletal muscle function following isolated tibial fractures

    Directory of Open Access Journals (Sweden)

    Haas Norbert P

    2008-04-01

    Full Text Available Abstract Background The severity of associated soft tissue trauma in complex injuries of the extremities guides fracture treatment and decisively determines patient's prognosis. Trauma-induced microvascular dysfunction and increased tissue pressure is known to trigger secondary soft tissue damage and seems to adversely affect skeletal muscle function. Methods 20 patients with isolated tibial fractures were included. Blood pressure and compartment pressure (anterior and deep posterior compartment were measured continuously up to 24 hours. Corresponding perfusion pressure was calculated. After 4 and 12 weeks isokinetic muscle peak torque and mean power of the ankle joint in dorsal and plantar flexion were measured using a Biodex dynamometer. Results A significant inverse correlation between the anterior perfusion pressure at 24 hours and deficit in dorsiflexion at 4 weeks was found for both, the peak torque (R = -0.83; p Conclusion The functional relationship between the decrease in intramuscular perfusion pressures and muscle performance in the early rehabilitation period indicate a causative and prognostic role of early posttraumatic microcirculatory derangements and skeletal muscle function. Therapeutic concepts aimed at effective muscle recovery, early rehabilitation, and decreased secondary tissue damage, should consider the maintenance of an adequate intramuscular perfusion pressure.

  11. Tl-201 myocardial perfusion scanning in patients with right bundle branch block coronary artery disease

    International Nuclear Information System (INIS)

    Shirani, J.; Malpani, A.R.; Blend, M.J.; Bekerman, C.

    1990-01-01

    This paper evaluates the specificity of stress T1-201 myocardial perfusion studies (T1-201 MPS) for coronary artery disease (CAD) in patients with right bundle branch block (RBBB). Twenty-four patients with RBBB and atypical chest pain with ECG findings limited to RBBB, adequate stress test (ie, >85% of maximal heart rate for age), and no clinical, hemodynamic, or ECG evidence of ischemia during exercise underwent T1-201 MPS. These perfusion patterns were compared with an equal number of age- and gender-matched controls with a normal ECG who met all other criteria mentioned above. Patients with RBBB showed a significantly higher frequency of reversible inferoposterior T1-201 defects (62.5% vs 20.8%)

  12. Model of the coronary circulation based on pressure dependence of coronary resistance and compliance

    NARCIS (Netherlands)

    Bruinsma, P.; Arts, T.; Dankelman, J.; Spaan, J. A.

    1988-01-01

    The effect of pressure-dependent changes in vascular volume, resistance and capacitance in the coronary micro-circulation, has been studied by a distributed mathematical model of the coronary micro-vasculature in the left ventricular wall. The model does not include regulation of coronary blood flow

  13. Distal coronary hemoperfusion during percutaneous transluminal coronary angioplasty

    NARCIS (Netherlands)

    Muinck, Ebo Derk de

    1994-01-01

    In this thesis several aspects of passive and active coronary perfusion during coronary angioplasty are investigated. The autoperfusion balloon catheters that were evaluated are the Stack® and the RX-60® catheters (Advanced Cardiovascular Systems, inc., Santa Clara, California, U.S.A). The coronary

  14. Effects of Scirpusin B, a polyphenol in passion fruit seeds, on the coronary circulation of the isolated perfused rat heart

    Directory of Open Access Journals (Sweden)

    Yutaka Matsumoto, Nozomi Gotoh, Shoko Sano, Kenkichi Sugiyama, Tatsuhiko Ito, Yohei Abe, Yumi Katano, Akira Ishihata

    2014-07-01

    Full Text Available Objective: Piceatannol, a polyphenol which is contained in passion fruits seed, is a derivative of resveratrol and is known to have antioxidant, anti-inflammatory and vasorelaxing activities. Passion fruits seed also contains a dimer of Piceatannol, Scirpusin B. The aim of this study was to investigate the effect of Scirpusin B on the coronary circulation of the isolated rat heart. Methods: Hearts were isolated from male Fischer 344 rats (5 – 6 months old, and perfused with modified Krebs-Henseleit solution aerated with 95% O2 and 5% CO2 (37 °C at constant pressure (75 cmH2O by Langendorff’s method. Piceatannol or Scirpusin B (10, 30 and 100 μM was injected as a bolus into the aortic cannula and coronary flow (CF was continuously measured by the electromagnetic flow meter. In some experiments, rat hearts were pretreated with L-NAME (an inhibitor of nitric oxide synthase or Diclofenac (an inhibitor of cyclooxygenase to reveal the possible involvement of nitric oxide (NO and vasodilating prostanoids in the effect of Scirpusin B. Results: Scirpusin B increased CF up to 108.2 % of the initial value, while Piceatannol did not increase CF. In addition; Scirpusin B increased CF concentration-dependently. Pretreatment with L-NAME or Diclofenac significantly attenuated the Scirpusin B-induced coronary vasodilatation. Scirpusin B did not change the heart rate either left ventricular pressure. Conclusion: This study shows that Scirpusin B could increase CF via production of NO and vasodilating prostanoids.

  15. Scintigraphy of the heart using sup(99m)Tc diphosphonate in combination with selective coronary perfusion scintigraphy and coronaroangiography

    International Nuclear Information System (INIS)

    Neumann, G.; Trenckmann, H.; Duck, H.J.; Katzschmann, R.; Neugebauerova, A.; Schneider, G.; Gottschild, D.

    1980-01-01

    In 45 patients with ischemic heart disease the results obtained by myocardial scintigraphy using technetium-99m diphosphonate (Tc-99m-DP) were compared with those obtained at selective coronary angiography and selective coronary perfusion scintigraphy. The cumulation of activity in the heart muscle was seen in twelve patients. This group is analyzed in the present paper in more detail. The ventriculographic examination of the left ventricle showed disturbed motility of the wall in six patients, of whom five had a positive myocardial scintigram. In view of this, myocardial scintigraphy using Tc-99m-DP may be considered a complementary, non-invasive method for proving significant disturbances of the motility of the heart wall. Positive myocardial scintigrams were also found in angna pectoris, in a patient after aorto-coronary bypass, in cardiomyopathy and myocarditis. In view of the fact that myocardial scintigraphy using Tc-99m-DP is capable of proving disturbances of cells of the heart muscle taking place at the moment, conclusions can be drawn as to the activity in the heart muscle. It further follows that myocardial scintigraphy may be significant in indicating the aorto-coronary bypass. We failed to prove an unequivocal correlation between myocardial scintigraphy, the number of sclerotically changed coronary vessels and the degree of their narrowing. An immediate relationship could not be proved between the extent of perfusion disturbance and the results of myocardial scintigraphy

  16. Can Stress Echocardiography Compete with Perfusion Scintigraphy in the Detection of Coronary Artery Disease and Cardiac Risk Assessment?

    NARCIS (Netherlands)

    M.L. Geleijnse (Marcel); A. Elhendy (Abdou)

    2000-01-01

    textabstractAims: The aim of this review was to define the place of stress echocardiography in the context of perfusion scintigraphy for the detection of coronary artery disease (CAD) and the assessment of cardiac risk. Stress echocardiography has the benefits of widespread availability, relatively

  17. Myocardial perfusion in patients with left bundle branch block and without coronary artery disease

    International Nuclear Information System (INIS)

    Narita, Michihiro; Kurihara, Tadashi; Murano, Kenichi; Usami, Masahisa; Honda, Minoru

    1992-01-01

    For the evaluation of myocardial perfusion in patients with left bundle branch block (LBBB), we performed exercise stress (Ex)-redistribution (RD) myocardial tomography with thallium-201 ( 201 Tl) in 23 patients with LBBB and without coronary artery disease (CAD). Myocardial images in patients with LBBB were compared with those of 9 patients with CAD who showed Ex induced transient septal defect. Bull'-eye maps ( 201 Tl distribution maps at Ex and RD and 201 Tl washout rate [WOR] map) were made from myocardial tomograms. In 23 patients with LBBB, 15 patients (65%) developed myocardial perfusion abnormality. In 10 (67%) of these 15 patients, transient perfusion defect appeared in the entire septum (diffuse type). On the other hand in 5 patients (33%), localized fixed perfusion defect developed at the boundary between septum and anterior wall (focal type). In focal type, every patient had other disease such as hypertension, aortic stenosis or sick sinus syndrome. While in patients with diffuse type, other diseases were observed in 30% (p 201 Tl WOR and 201 Tl uptake ratio of septum to lateral wall indicated that exercise induced septal defect was slighter in diffuse type than CAD. These points might be useful to differentiate whether CAD participates in the septal defect or not in patients with LBBB. (author)

  18. Endocardial-epicardial distribution of myocardial perfusion reserve assessed by multidetector computed tomography in symptomatic patients without significant coronary artery disease

    DEFF Research Database (Denmark)

    Kühl, Jørgen Tobias; George, Richard T; Mehra, Vishal C

    2016-01-01

    (MPR) in humans. We aimed to test the hypothesis that MPR in all myocardial layers is determined by age, gender, and cardiovascular risk profile in patients with ischaemic symptoms or equivalent but without obstructive coronary artery disease (CAD). METHODS AND RESULTS: A total of 149 patients enrolled...... in endocardial-epicardial distribution of perfusion reserve may be demonstrated with static CT perfusion. Low MPR in all myocardial layers was observed specifically in obese patients....

  19. Improvements in the technique of vascular perfusion-fixation employing a fluorocarbon-containing perfusate and a peristaltic pump controlled by pressure feedback

    DEFF Research Database (Denmark)

    Rostgaard, J; Qvortrup, Klaus; Poulsen, Steen Seier

    1993-01-01

    A new improved technique for whole-body perfusion-fixation of rats and other small animals is described. The driving force is a peristaltic pump which is feedback regulated by a pressure transducer that monitors the blood-perfusion pressure in the left ventricle of the heart. The primary perfusate...... to cannulate the heart; the outer and inner barrels of the cannula are connected to the peristaltic pump and to the pressure transducer, respectively. The tissue oxygen tension in the rat is monitored by a subcutaneous oxygen electrode. Measurements showed that tissue hypoxia/anoxia did not develop before......-fixative is composed of a blood substitute--13.3% oxygenated fluorocarbon FC-75--in 0.05 M cacodylate buffer (pH 7.4) with a 2% glutaraldehyde. The secondary perfusate-fixative is composed of 2% glutaraldehyde in 0.05 M cacodylate buffer (pH 7.4) with 20 mM CaCl2. A double-barrelled, self-holding cannula is used...

  20. Comparison of single-dose and double-dose thallium-201 myocardial perfusion scintigraphy for the detection of coronary artery disease and prior myocardial infarction

    International Nuclear Information System (INIS)

    Blood, D.K.; McCarthy, D.M.; Sciacca, R.R.; Cannon, P.J.

    1978-01-01

    Thallium-201 myocardial perfusion scintigraphy was performed after exercise, 4 hours after exercise (redistribution) and after a separate rest injection in 87 patients undergoing coronary arteriography. Significant coronary lesions were present in 62 of the patients. Interpretation of the rest and redistribution scintiscans was the same in 69 patients, 45 of whom had coronary artery disease (CAD). In 16 of the 17 patients with CAD and differing interpretations, defects were present on redistribution scintiscans but not on rest scintiscans; 11 of these patients had evidence of prior transmural myocardial infarction and the other five had an occluded coronary artery supplying the region of the defect. Redistribution scintiscans were more sensitive than rest scintiscans for the detection of prior myocardial infarction (93% vs 54%; P < 0.01). The increased sensitivity was confined to the detection of prior inferior myocardial infarctions. In 36 of 38 patients with persistent perfusion defects on 4-hour redistribution scintiscans, either a prior infarction or an occluded coronary vessel was present. These data demonstrate that redistribution thallium-201 scintiscans may be substituted for conventional rest scintiscans, resulting in reduced cost and radiation exposure to the patients

  1. Single Coronary Artery with Aortic Regurgitation

    International Nuclear Information System (INIS)

    Katsetos, Manny C.; Toce, Dale T.

    2003-01-01

    An isolated single coronary artery can be associated with normal life expectancy; however, patients are at an increased risk of sudden death. A case is reported of a 54-year-old man with several months of chest pressure with activity. On exercise Sestamibi stress testing, the patient developed a hypotensive response with no symptoms and minimal electrocardiographic changes. Nuclear scanning demonstrated reversible septal and lateral perfusion defects consistent with severe ischemia. Coronary angiography revealed a single coronary artery with the right coronary artery arising from the left main. There were high-grade stenotic lesions in the left anterior descending and circumflex arteries with only moderate atherosclerotic disease in the right coronary artery. An aortogram showed 2-3+ aortic regurgitation, with an ejection fraction of 45% on ventriculography. The patient underwent four-vessel revascularization and aortic valve replacement and did well postoperatively

  2. The dynamics of the coronary collateral circulation.

    Science.gov (United States)

    Zimarino, Marco; D'Andreamatteo, Mariangela; Waksman, Ron; Epstein, Stephen E; De Caterina, Raffaele

    2014-04-01

    Coronary collaterals are present at birth, with wide interindividual variation in their functional capacity. These vessels protect jeopardized myocardium, and the number of collaterals and the extent of their coverage are associated with improved survival in patients with coronary heart disease. The collateral circulation is not a permanent set of structures, but undergoes dynamic changes with important consequences for cardioprotection. If a severe atherosclerotic lesion develops in an artery supplying tissue downstream of a total occlusion through collateral blood flow, pressure gradients across the collateral bed change. The result is that some of the collateral flow previously supplying the perfusion territory of the totally occluded artery is redirected to the perfusion territory of the donor artery, thus producing a 'collateral steal'. The collateral circulation can regress once antegrade flow in the main dependent artery is re-established, as occurs following the recanalization of a chronic total occlusion. The clinical benefits of coronary revascularization must be cautiously weighed against the risk of reducing the protective support derived from coronary collaterals. Consequently, pharmacological, gene-based, and cell-based therapeutic attempts have been made to enhance collateral function. Although such approaches have so far yielded no, or modest, beneficial results, the rapidly accruing data on coronary collateral circulation will hopefully lead to new effective therapeutic strategies.

  3. Directly measuring spinal cord blood flow and spinal cord perfusion pressure via the collateral network: correlations with changes in systemic blood pressure.

    Science.gov (United States)

    Kise, Yuya; Kuniyoshi, Yukio; Inafuku, Hitoshi; Nagano, Takaaki; Hirayasu, Tsuneo; Yamashiro, Satoshi

    2015-01-01

    During thoracoabdominal surgery in which segmental arteries are sacrificed over a large area, blood supply routes from collateral networks have received attention as a means of avoiding spinal cord injury. The aim of this study was to investigate spinal cord blood supply through a collateral network by directly measuring spinal cord blood flow and spinal cord perfusion pressure experimentally. In beagle dogs (n = 8), the thoracoabdominal aorta and segmental arteries L1-L7 were exposed, and a temporary bypass was created for distal perfusion. Next, a laser blood flow meter was placed on the spinal dura mater in the L5 region to measure the spinal cord blood flow. The following were measured simultaneously when the direct blood supply from segmental arteries L2-L7 to the spinal cord was stopped: mean systemic blood pressure, spinal cord perfusion pressure (blood pressure within the aortic clamp site), and spinal cord blood flow supplied via the collateral network. These variables were then investigated for evidence of correlations. Positive correlations were observed between mean systemic blood pressure and spinal cord blood flow during interruption of segmental artery flow both with (r = 0.844, P flow with and without distal perfusion (r = 0.803, P network from outside the interrupted segmental arteries, and high systemic blood pressure (∼1.33-fold higher) was needed to obtain the preclamping spinal cord blood flow, whereas 1.68-fold higher systemic blood pressure was needed when distal perfusion was halted. Spinal cord blood flow is positively correlated with mean systemic blood pressure and spinal cord perfusion pressure under spinal cord ischemia caused by clamping a wide range of segmental arteries. In open and endovascular thoracic and thoracoabdominal surgery, elevating mean systemic blood pressure is a simple and effective means of increasing spinal cord blood flow, and measuring spinal cord perfusion pressure seems to be useful for monitoring

  4. Diastolic coronary artery pressure-flow velocity relationships in conscious man.

    Science.gov (United States)

    Dole, W P; Richards, K L; Hartley, C J; Alexander, G M; Campbell, A B; Bishop, V S

    1984-09-01

    We characterised the diastolic pressure-flow velocity relationship in the normal left coronary artery of conscious man before and after vasodilatation with angiographic contrast medium. Phasic coronary artery pressure and flow velocity were measured in ten patients during individual diastoles (0.5 to 1.0 s) using a 20 MHz catheter-tipped, pulsed Doppler transducer. All pressure-flow velocity curves were linear over the diastolic pressure range of 110 +/- 15 (SD) mmHg to 71 +/- 7 mmHg (r = 0.97 +/- 0.01). In the basal state, values for slope and extrapolated zero flow pressure intercept averaged 0.35 +/- 0.12 cm X s-1 X mmHg-1 and 51.7 +/- 8.6 mmHg, respectively. Vasodilatation resulted in a 2.5 +/- 0.5 fold increase in mean flow velocity. The diastolic pressure-flow velocity relationship obtained during peak vasodilatation compared to that during basal conditions was characterised by a steeper slope (0.80 +/- 0.48 cm X s-1 X mmHg-1, p less than 0.001) and lower extrapolated zero flow pressure intercept (37.9 +/- 9.8 mmHg, p less than 0.05). Mean right atrial pressure for the group averaged 4.4 +/- 1.7 mmHg, while left ventricular end-diastolic pressure averaged 8.7 +/- 2.8 mmHg. These observations in man are similar to data reported in the canine coronary circulation which are consistent with a vascular waterfall model of diastolic flow regulation. In this model, coronary blood flow may be regulated by changes in diastolic zero flow pressure as well as in coronary resistance.

  5. Role of pressure in angiotensin II-induced renal injury: chronic servo-control of renal perfusion pressure in rats.

    Science.gov (United States)

    Mori, Takefumi; Cowley, Allen W

    2004-04-01

    Renal perfusion pressure was servo-controlled chronically in rats to quantify the relative contribution of elevated arterial pressure versus angiotensin II (Ang II) on the induction of renal injury in Ang II-induced hypertension. Sprague-Dawley rats fed a 4% salt diet were administered Ang II for 14 days (25 ng/kg per minute IV; saline only for sham rats), and the renal perfusion pressure to the left kidney was continuously servo-controlled to maintain a normal pressure in that kidney throughout the period of hypertension. An aortic occluder was implanted around the aorta between the two renal arteries and carotid and femoral arterial pressure were measured continuously throughout the experiment to determine uncontrolled and controlled renal perfusion pressure, respectively. Renal perfusion pressure of uncontrolled, controlled, and sham kidneys over the period of Ang II or saline infusion averaged 152.6+/-7.0, 117.4+/-3.5, and 110.7+/-2.2 mm Hg, respectively. The high-pressure uncontrolled kidneys exhibited tubular necrosis and interstitial fibrosis, especially prominent in the outer medullary region. Regional glomerular sclerosis and interlobular artery injury were also pronounced. Controlled kidneys were significantly protected from interlobular artery injury, juxtamedullary glomeruli injury, tubular necrosis, and interstitial fibrosis as determined by comparing the level of injury. Glomerular injury was not prevented in the outer cortex. Transforming growth factor (TGF)-beta and active NF-kappaB proteins determined by immunohistochemistry were colocalized in the uncontrolled kidney in regions of interstitial fibrosis. We conclude that the preferential juxtamedullary injury found in Ang II hypertension is largely induced by pressure and is probably mediated through the TGF-beta and NF-kappaB pathway.

  6. Estimation of bone perfusion as a function of intramedullary pressure in sheep

    International Nuclear Information System (INIS)

    Rosenthal, M.S.; Lehner, C.E.; Pearson, D.W.; Kanikula, T.M.; Adler, G.G.; Venci, R.; Lanphier, E.H.; De Luca, P.M.

    1985-01-01

    It has been reported previously that following decompression (i.e. diving ascents) the intramedullary pressure (IMP) in bone can rise dramatically and possibly by the mechanism which can induce dysbaric osteonecrosis or the ''silent bends''. If the blood supply for the bone transverses the marrow compartment, than an increase in IMP could cause a temporary decrease in perfusion or hemostasis and hence ischemia leading to bone necrosis. To test this hypothesis, the authors measured the perfusion of bone in sheep as a function of IMP. The bone perfusion was estimated by measuring the perfusion-limited clearance of Ar-41 (Eγ=1293 keV, T/sub 1/2/=1.83 h) from the bone mineral matrix of sheep's tibia. The argon gas was formed in vivo by the fast neutron activation of Ca-44 to Ar-41 following the Ca-44(n,α) reaction. Clearance of Ar-41 was measured by time gated gamma-ray spectroscopy. These results indicate that an elevation of intramedullary pressure can decrease perfusion in bone and may cause bone necrosis

  7. Non invasive evaluation of the coronary atherosclerosis illness in patients with silent ischemia: utility of the SPECT of myocardial perfusion. Electric, angiographic and image correlation

    International Nuclear Information System (INIS)

    Puente B, A.; Roffe G, F.; Aceves C, J.; Gomez A, E.

    2005-01-01

    The objective of the work was to determine the utility of the SPECT (Single Photon Emission Computerized Tomography) of myocardial perfusion for the ischemia detection in asymptomatic patients with Coronary Atherosclerosis Illness. It was concluded that the SPECT of myocardial perfusion has a high sensitivity (97%) for the silent ischemia diagnosis

  8. Regadenoson in the detection of coronary artery disease

    Directory of Open Access Journals (Sweden)

    Christiane Buhr

    2008-04-01

    Full Text Available Christiane Buhr1, Mario Gössl2, Raimund Erbel1, Holger Eggebrecht11Department of Cardiology, West-German Heart Center Essen, University of Duisburg-Essen, Essen, Germany; 2Cardiovascular Diseases, Mayo Clinic College of Medicine, Rochester, MN 55905, USAAbstract: Myocardial perfusion studies use either physical exercise or pharmacologic vasodilator stress to induce maximum myocardial hyperemia. Adenosine and dipyridamole are the most commonly used agents to induce coronary arterial vasodilation for myocardial perfusion imaging. Both cause frequent undesirable side-effects. Because of its ultrashort half-life, adenosine must be administered by constant intravenous infusion during the examination. A key feature of an ideal A2A agonist for myocardial perfusion imaging studies would be an optimal level and duration of hyperemic response. Drugs with a longer half-time and more selective A2A adenosine receptor agonism, such as regadenoson, should theoretically result in a similar degree of coronary vasodilation with fewer or less severe side-effects than non-selective, ultrashort-lasting adenosine receptor stimulation. The available preclinical and clinical data suggest that regadenoson is a highly subtype-selective, potent, low-affinity A2A adenosine receptor agonist that holds promise for future use as a coronary vasodilator in myocardial perfusion imaging studies. Infusion of regadenoson achieves maximum coronary hyperemia that is equivalent to adenosine. After a single bolus infusion over 10 s, hyperemia is maintained significantly longer (approximately 2–5 min than with adenosine, which should facilitate radionuclide distribution for myocardial perfusion imaging studies. In comparison with the clinically competitive A2A adenosine receptor agonist binodenoson, regadenoson has a several-fold shorter duration of action, although the magnitude of hyperemic response is comparable between the two. The more rapid termination of action of regadenoson

  9. Pretest clinical diagnosis of coronary artery disease and stress myocardial perfusion scintigram

    International Nuclear Information System (INIS)

    Kasalicky, J.; Kovac, I.; Lanska, V.

    2001-01-01

    To assess the probability of perfusion defects at exercise stress myocardial perfusion SPECT scintigraphy from pretest clinical diagnosis (medical personal history, previous ergometric investigation). To determine the value of clinical factors for probability of scintigraphic defects with respect to avoiding unnecessary investigation in subjects with low probability of abnormal scintigrams. 2143 subjects (1235 men, 908 women) were investigated by SPECT perfusion scintigraphy at stepwise increasing exercise stress. They were divided into three groups with regard to their medical history and exercise test at scintigraphy: subjects without any signs of coronary artery disease (CAD), patients with high likelihood of CAD (i.e., typical anginal pain, in particular at stress, positive stress ECG changes, angiographically documented important CAD) and patients after myocardial infarction (MI). Important risk factors (hypertension, diabetes, age and sex), as well as the role of revascularisation procedures, were taken into account for multiple logistic regression in order to express their importance for the odds of scintigraphic defect visualisation. Perfusion scintigraphic defects (PSD) were found in 5.2% of subjects without signs of CAD, in contrast to patients with manifest CAD (68.8% with PSD) and in those after MI (90.2% with PSD). There were other important factors corroborating the likelihood of PSD (in decreasing order of importance): diabetes, male, ECG changes at stress, increasing age. Successful revascularisation improved scintigraphic images. The examination of CAD symptom-free subjects, in particular with atypical chest discomfort, is useless. SMPS in patients after documented MI is to be carried out for other intended purposes, not for CAD diagnosis only. SMPS is highly recommended in patients with CAD symptoms and high CAD probability in order to decide further treatment and prognosis. (author)

  10. Pseudonormalization of transmitral flow pattern during exercise thallium-201 imaging in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Shiota, Takahiro; Sakamoto, Tsuguya; Takenaka, Katsu; Amano, Keiko; Amano, Wataru; Igarashi, Tsutomu; Otake, Takeshi; Sugimoto, Tsuneaki

    1993-01-01

    This study was undertaken to assess the usefulness of Doppler parameters and transmitral blood velocity for detecting abnormalities of left ventricular diastolic function during low-level exercise thallium-201 imaging. The study population consisted of 16 thallium perfusion defect patients with coronary artery disease (mean 61±8 years) and 21 age-matched control subjects (mean 55±5 years) without any thallium perfusion defect. Of the 16 thallium perfusion defect patients, 12 were examined by coronary arteriography, of whom single vessel coronary artery disease was seen in 2 and multivessel coronary artery disease in 10. Patients with mitral regurgitant murmurs were excluded from the study. Peak mitral blood flow velocity was measured in early diastole (E) and during atrial systole (A) and the A/E ratio was calculated. The changes in blood pressure and heart rate after low-level exercise were not significantly different between control and thallium perfusion defect groups. The A/E ratio increased slightly in control subjects from 93±14% at baseline to 100±15% during low-level exercise (p<0.05), whereas in patients with thallium perfusion defect, it decreased significantly from 119±33% at baseline to 92±23% during low-level exercise (p<0.01). Thus pseudonormalization of the A/E ratio during low-level exercise may be valuable in the evaluation of patients with severe or multivessel coronary artery disease. (author)

  11. Comparing effects of perfusion and hydrostatic pressure on gene profiles of human chondrocyte.

    Science.gov (United States)

    Zhu, Ge; Mayer-Wagner, Susanne; Schröder, Christian; Woiczinski, Matthias; Blum, Helmut; Lavagi, Ilaria; Krebs, Stefan; Redeker, Julia I; Hölzer, Andreas; Jansson, Volkmar; Betz, Oliver; Müller, Peter E

    2015-09-20

    Hydrostatic pressure and perfusion have been shown to regulate the chondrogenic potential of articular chondrocytes. In order to compare the effects of hydrostatic pressure plus perfusion (HPP) and perfusion (P) we investigated the complete gene expression profiles of human chondrocytes under HPP and P. A simplified bioreactor was constructed to apply loading (0.1 MPa for 2 h) and perfusion (2 ml) through the same piping by pressurizing the medium directly. High-density monolayer cultures of human chondrocytes were exposed to HPP or P for 4 days. Controls (C) were maintained in static cultures. Gene expression was evaluated by sequencing (RNAseq) and quantitative real-time PCR analysis. Both treatments changed gene expression levels of human chondrocytes significantly. Specifically, HPP and P increased COL2A1 expression and decreased COL1A1 and MMP-13 expression. Despite of these similarities, RNAseq revealed a list of cartilage genes including ACAN, ITGA10 and TNC, which were differentially expressed by HPP and P. Of these candidates, adhesion related molecules were found to be upregulated in HPP. Both HPP and P treatment had beneficial effects on chondrocyte differentiation and decreased catabolic enzyme expression. The study provides new insight into how hydrostatic pressure and perfusion enhance cartilage differentiation and inhibit catabolic effects. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Diagnosis of severe and extensive coronary artery disease using gated myocardial perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Ihn Ho; Lee, Hyoung Woo; Won, Kyu Chang; Park, Jong Sun; Sin, Dog Gu; Kim, Young Jo; Shim, Bong Sub [College of Medicine, Yeungnam Univ., Taegu (Korea, Republic of)

    1999-07-01

    Left ventricular volumes and ejection fractions constitute important informations in the diagnosis and prognosis of cardiac disease. Aim of the study is to verify if the assessment of left ventricular function and perfusion together by gated myocardial perfusion SPECT is useful for diagnosing severe and extensive CAD. We examined 27 consecutive patients (17 males and 10 females, mean age : 60.1 years) who underwent two day rest/stress Tc-99m MIBI gated SPECT. Stress was done with adenosine. Post-stress gated SPECT was done at 1 hour after an injection of Tc-99m MIBI (740 MBq). All patients underwent coronary angiography after gated SPECT within 1 month. We divided them three groups with single vessel disease, double vessel disease and triple vessel disease or severe proximal left coronary artery stenosis. Extent of Defect (ED), Reversibility of Extent (RE), Severity of Defect (SD) and Severity of Reversibility (SR) were calculated by CEqual program. Post-stress LVEF, Rest LVEF, End-diastolic volume(EDV), End-systolic volume(ESV), Transient Ischemic Dilation (TID) of left ventricle (Post-stress EDV/Rest EDV) were calculated using gated SPECT quantification program. Left ventricle is divided with 18 segments and wall motion was scored (normal=0, mild hypokinesia =1, severe hypokinesia =2, akinesia =3 and dyskinesia =4), and then post-stress summed wall motion score was calculated. Post-stress summed wall motion score and post-stress LVEF were significant differences between three groups ( P <0.01). Extent of defect, Extent of reversibility, Severity of defect and severity of reversibility in Polar map were significant differences between three groups ( P <0.01). Post-stress Transient left ventricular dilatation and test LVEF were not significant differences between three groups ( P > 0.05). The gated SPECT pattern (low post-stress LVEF and post-stress summed wall motion score) add important diagnostic information over ungated perfusion data (high ED, ER and SR and

  13. Note: A micro-perfusion system for use during real-time physiological studies under high pressure

    Science.gov (United States)

    Maltas, Jeff; Long, Zac; Huff, Alison; Maloney, Ryan; Ryan, Jordan; Urayama, Paul

    2014-10-01

    We construct a micro-perfusion system using piston screw pump generators for use during real-time, high-pressure physiological studies. Perfusion is achieved using two generators, with one generator being compressed while the other is retracted, thus maintaining pressurization while producing fluid flow. We demonstrate control over perfusion rates in the 10-μl/s range and the ability to change between fluid reservoirs at up to 50 MPa. We validate the screw-pump approach by monitoring the cyanide-induced response of UV-excited autofluorescence from Saccharomyces cerevisiae under pressurization.

  14. Regional myocardial perfusion in patients with atherosclerotic coronary artery disease, at rest and during angina pectoris induced by tachycardia

    International Nuclear Information System (INIS)

    Maseri, A.; L'Abbate, A.; Pesola, A.; Michelassi, C.; Marzilli, M.; De Nes, M.

    1977-01-01

    We studied regional myocardial perfusion by scintigraphic computer-assisted analysis of initial distribution, washout rates, and residual activity of 133 Xe injected into the left coronary artery of four patients with normal arteriograms and 14 patients with coronary stenosis. At rest, residual activity in poststenotic regions was always greater than in control regions, but initial washout rates were not slower. During angina, following xenon injections, the amount of indicator distributed to the poststenotic regions was markedly reduced; the increase of the initial washout rates was smaller than in control regions relative to rest, and residual activity was higher. Initial washout rates did not differ as much as from those of normal myocardium because in severe ischemia too little indicator is deposited initially in these regions to produce a change of any magnitude. Indeed, when angina was induced immediately after the xenon injection, poststenotic washout rates became much slower during angina than at rest, a finding that implicates functional factors in impairing poststenotic myocardial perfusion during angina

  15. Nuclear medicine and coronary artery disease: evaluation of tracers of myocardial perfusion and vulnerable atherosclerotic plaque

    International Nuclear Information System (INIS)

    Broisat, A.

    2005-04-01

    Coronary artery disease is one of the primary cause of mortality worldwide. Nuclear medicine is the major imaging technique for diagnosis and following of this disease. perfusion: nowadays, major radioactive agents used in clinical practice are myocardial perfusion tracers. The reference tracer is thallium-201. However, 201 Tl presents some drawbacks. 99m Tcn-noet has been proposed for its replacement. This study shows that in contrast with previous studies realized in vitro on cardio myocytes, verapamil, an l-type calcium channel inhibitor, does not inhibit myocardial fixation of 99m Tcn-noet in vivo in dog. This data is in agreement with the hypothesis of a non specific endothelial fixation of this tracer. Moreover, this study shows that as a pure tracer of myocardial perfusion, 99m Tcn-noet can also be used to assess myocardial viability on a model of myocardial chronic infarction in rat. atherosclerosis: disruption of vulnerable atherosclerotic plaques is the main event leading to coronary accidents. The second part of this study concerns the evaluation of new potential tracers of the vulnerable atherosclerotic plaque in an experimental model of rabbit with an inheritable hypercholesterolemia. The four tracers evaluated (b2702(r), b2702-I, b2702-Tc and Tc-raft-b2702) are synthetic peptides comprising the residues 75-84 of hla-b2702, a molecule known to link vcam-1, an adhesion molecule expressed in vulnerable atherosclerotic plaque. The autoradiography studies show that all tracers accumulate within atherosclerotic plaque expressing vcam- and that. i-b2702 shows the best plaque/control fixation ratio. (author)

  16. Reverse 201Tl myocardial redistribution induced by coronary artery spasm

    International Nuclear Information System (INIS)

    Xiang Dingcheng; Yin Jilin; Gong Zhihua; Xie Zhenhong; Zhang Jinhe; Wen Yanfei; Yi Shaodong

    2010-01-01

    Objective: To investigate the mechanism of reverse redistribution (RR) on dipyridamole 201 Tl myocardial perfusion studies in the patients with coronary artery spasm. Methods: Twenty-six patients with coronary artery spasm and presented as RR on dipyridamole 201 Tl myocardial perfusion studies were enlisted as RR group, while other 16 patients with no coronary artery stenosis nor RR were enlisted as control group. Dipyridamole test was repeated during coronary angiography. Corrected thrombolysis in myocardial infarction (TIMI) frame count (CTFC) and TIMI myocardial perfusion grade (TMPG) were measured at RR related and non-RR related coronary arteries before and after dipyridamole infusion respectively. All of the data were analyzed by Student's t-test or χ 2 -test and correlation analysis. Results: Coronary artery angiography showed slower blood flow and lower myocardial perfusion in RR related vessels when compared with non-RR related vessels in RR group, but there was no significant difference among the main coronary arteries in control group. The perfusion defects of RR area at rest were positively related to slower blood velocity at corresponding coronary arteries (r = 0.79, t =10.18, P 0.05). Conclusion: RR is related to the decreased blood flow and myocardial perfusion induced by coronary artery spasm at rest, which may be improved by stress test such as intravenous dipyridamole infusion. (authors)

  17. The value of regional wall motion abnormalities on gated mycardiac perfusion imaging in perfusion imaging in predicting angiographic stenoses of coronary artery

    International Nuclear Information System (INIS)

    Yao Lixin; Liu Binbin

    2007-01-01

    Objective: To determine the possible level of angiographic stenoses of coronary artery at which reversible regional wall motion abnormalities (RWMA) are present on 99m Tc-sestamibi ( 99m Tc-MIBI)-gated myocardial perfusion imaging (MPI). Methods: ninty patients undergoing coronary angiography MPI within two weeks were recruited. A five grades and nine segments marking system was introduced to assess the RWMA and thickening of left ventricles. Results: The sensitivity of reversible RWMA for detecting ≥75% angiographic stenoses was 64%,with a specificity of 95% and positive predictive value of 97%. The presence of reversible RWMA was able to stratify patients with severe angiographic stenoses of 75% or more from those less than 75% with high positive predictive value. A good correlation was noted between the presence of reversible RWMA and the coronary artery jeopardy score. Multivariate analysis showed that the post-stress RWMA and reversible RWMA scores and positive dipyridamole-stress exercise electrocardiogram(ECG) were significant predictors of angiographic severity. Conclusions: Reversible RWMA, as shown by dipyridamole stress 99m Tc-MIBI MPI, is a significant predictor of angiographic disease with very high specificity and adds incremental value to MPI for the assessment of angiographic severity. (authors)

  18. Effects of perfusion pressure and insulin on (3H) cytochalasin B (CB) binding to control and diabetic rat hearts

    International Nuclear Information System (INIS)

    Pleta, M.; Chan, T.

    1987-01-01

    Using ( 3 H) CB, they attempted to quantitate the changes in the amount of glucose transporters in the plasma membrane (PM) and intracellular membranes (HSP) prepared from rat hearts perfused with insulin, under low and high pressure. Membranes isolated from non-perfused hearts showed a PM/HSP ratio of (0.593). Hearts perfused with low pressure showed a lower ratio of (0.474). Perfusion with insulin increased the ratio to (1.8), almost a 3-4 fold increase from low perfusion pressure. These data correlate with insulin effects in glucose transport and CB binding in the fat cells. High pressure perfusion increased the PM/HSP ratio by 1-2 fold. ( 3 H) 2-DG transport indicates a comparable increase in glucose uptake with high pressure, but with insulin only a 1.5 fold increase was observed. Initial data obtained from streptozotocin (STZ) injected diabetic rats indicate low CB binding in the PM fraction. Only insulin, but not high perfusion pressure increased PM/HSP ratio in the STZ-diabetic hearts. Their data imply that while both caused apparent translocation of glucose transporters, influences on cardiac glucose metabolism by work load are different. Furthermore, STZ induced diabetes affected only the high perfusion pressure-induced and not the insulin-stimulated change in CB binding

  19. Pressure Myography to Study the Function and Structure of isolated small arteries

    DEFF Research Database (Denmark)

    Schjørring, Olav; Carlsson, Rune; Simonsen, Ulf

    2015-01-01

    Small arteries play an important role in regulation of peripheral resistance and organ perfusion. Here we describe a series of the methods allowing measurements in pressurized segments of small arteries from the systemic and coronary circulation of mice as well as other species. The pressure...... myography techniques described include measurements of wall structure, wall stress, strain, and of myogenic tone. The pressurized perfused small arteries also allow evaluation of responses to increases in pressure, flow, and drugs, where the main readout is changes in vascular diameter....

  20. A relative study of hepatic perfusion and portal vein pressure in rats with liver cirrhosis

    International Nuclear Information System (INIS)

    Li Jiaping; Yang Jianyong; Chen Wei; Huang Yonghui

    2006-01-01

    Objective: To evaluate spiral CT perfusion in assessing portal vein pressure in rats with different stages of liver cirrhosis. Methods Seventeen rats with early stage of liver cirrhosis, 18 with intermediate stage, 12 with advanced stage, and 13 healthy rats as a control group were selected and recieved hepatic perfusion on a single-row spiral CT scanner. The parameters of hepatic perfusion were calculated using the deconvolution method. The portal vein pressure was measured by multi-physiographer. Results: (1) In study group, the PVP (portal venous perfusion) and THBP (total hepatic blood perfusion) were negatively correlated with FPP, while positively correlated with the HPI (hepatic perfusion index) and MTT (mean transit time). The FPP had a close relation with PVP. The equation, Y 20.671-3.195X, could be conducted with linear regression analysis. (2) According to the linear regression equation mentioned above, the FPP in 47 rats were 16.090±2.150 cmH 2 0, which was highly correlated with the observed valuel6.108±3.662 cmH 2 O (r=0.823 P<0.01). Conclusion: CT perfusion is a new non-invasive and efficient modality for assessment of the portal pressure in liver cirrhosis in various stages. (authors)

  1. Simultaneous determination of left ventricular perfusion and function

    International Nuclear Information System (INIS)

    Gremillet, E.; Champailler, A.; Esquerre, J.P.; Ouhayoun, E.; Coca, F.; Furber, A.; Le Jeune, J.J.

    1997-01-01

    Myocardial perfusion scintigraphy is a very useful tool for the diagnosis and prognosis of coronary artery disease. The evaluation of left ventricular function during stress testing in also very useful to determine the prognosis of coronary artery disease. This chapter highlights three different imaging methods to assess left ventricular function and myocardial perfusion/ The first one consists of sequential dual isotope myocardial SPECT with ECG-gating. The second concerns magnetic resonance imaging and the third explores first pass exercise ventriculography and myocardial perfusion scintigraphy simultaneously evaluated by means of 99m Tc-sestamibi. (authors)

  2. TU-G-204-01: BEST IN PHYSICS (IMAGING): Dynamic CT Myocardial Perfusion Measurement and Its Comparison to Fractional Flow Reserve

    Energy Technology Data Exchange (ETDEWEB)

    Ziemer, B; Hubbard, L; Groves, E; Sadeghi, B; Javan, H; Lipinski, J; Molloi, S [University of California, Irvine, CA (United States)

    2015-06-15

    Purpose: To evaluate a first pass analysis (FPA) technique for CT perfusion measurement in a swine animal and its validation using fractional flow reserve (FFR) as a reference standard. Methods: Swine were placed under anesthesia and relevant physiologic parameters were continuously recorded. Intra-coronary adenosine was administered to induce maximum hyperemia. A pressure wire was advanced distal to the first diagonal branch of the left anterior descending (LAD) artery for FFR measurements and a balloon dilation catheter was inserted over the pressure wire into the proximal LAD to create varying levels of stenosis. Images were acquired with a 320-row wide volume CT scanner. Three main coronary perfusion beds were delineated in the myocardium using arteries extracted from CT angiography images using a minimum energy hypothesis. The integrated density in the perfusion bed was used to calculate perfusion using the FPA technique. The perfusion in the LAD bed over a range of stenosis severity was measured. The measured fractional perfusion was compared to FFR and linear regression was performed. Results: The measured fractional perfusion using the FPA technique (P-FPA) and FFR were related as P-FPA = 1.06FFR – 0.06 (r{sup 2} = 0.86). The perfusion measurements were calculated with only three to five total CT volume scans, which drastically reduces the radiation dose as compared with the existing techniques requiring 15–20 volume scans. Conclusion: The measured perfusion using the first pass analysis technique showed good correlation with FFR measurements as a reference standard. The technique for perfusion measurement can potentially make a substantial reduction in radiation dose as compared with the existing techniques.

  3. TU-G-204-01: BEST IN PHYSICS (IMAGING): Dynamic CT Myocardial Perfusion Measurement and Its Comparison to Fractional Flow Reserve

    International Nuclear Information System (INIS)

    Ziemer, B; Hubbard, L; Groves, E; Sadeghi, B; Javan, H; Lipinski, J; Molloi, S

    2015-01-01

    Purpose: To evaluate a first pass analysis (FPA) technique for CT perfusion measurement in a swine animal and its validation using fractional flow reserve (FFR) as a reference standard. Methods: Swine were placed under anesthesia and relevant physiologic parameters were continuously recorded. Intra-coronary adenosine was administered to induce maximum hyperemia. A pressure wire was advanced distal to the first diagonal branch of the left anterior descending (LAD) artery for FFR measurements and a balloon dilation catheter was inserted over the pressure wire into the proximal LAD to create varying levels of stenosis. Images were acquired with a 320-row wide volume CT scanner. Three main coronary perfusion beds were delineated in the myocardium using arteries extracted from CT angiography images using a minimum energy hypothesis. The integrated density in the perfusion bed was used to calculate perfusion using the FPA technique. The perfusion in the LAD bed over a range of stenosis severity was measured. The measured fractional perfusion was compared to FFR and linear regression was performed. Results: The measured fractional perfusion using the FPA technique (P-FPA) and FFR were related as P-FPA = 1.06FFR – 0.06 (r 2 = 0.86). The perfusion measurements were calculated with only three to five total CT volume scans, which drastically reduces the radiation dose as compared with the existing techniques requiring 15–20 volume scans. Conclusion: The measured perfusion using the first pass analysis technique showed good correlation with FFR measurements as a reference standard. The technique for perfusion measurement can potentially make a substantial reduction in radiation dose as compared with the existing techniques

  4. Collateral Function in Patients with Coronary Occlusion Evaluated by 201Thallium Scintigraphy

    Directory of Open Access Journals (Sweden)

    Aida Hasanović

    2008-11-01

    Full Text Available The present study evaluated the impact of the angiographically documented collaterals on regional myocardial perfusion measured by 201thallium scintigraphy in patients with a chronic total occlusion.The study included 60 patients with chronic total occlusion who underwent rest-stress myocardial perfusion scintigraphy and coronary angiography. All patients had angiographic evidence of coronary collaterals. Patients were divided into two groups: group one had well-developed coronary collateral vessels (n=35 and group II had poor coronary collateral development (n=25.Patients with chronic total occlusion had severe and extensive stress-induced myocardial perfusion defects regardless of the grade of angiographic coronary collaterals. The perfusion defects in the group with good collaterals were predominantly reversible, suggesting that coronary collaterals preserved myocardial viability in the regions subtended by a total coronary occlusion. A significant correlation between good collaterals with complete protection and poor collaterals with no protection was noted.Our results demonstrate a protective effect of collaterals on myocardial perfusion during coronary occlusion. The effective angiographic collaterals may prevent resting regional wall motion abnormalities but do not appear to protect against stress-induced perfusion defect.

  5. Continuous determination of optimal cerebral perfusion pressure in traumatic brain injury

    NARCIS (Netherlands)

    Aries, M.J.H.; Czosnyka, Marek; Budohoski, Karol P.; Steiner, Luzius A.; Lavinio, Andrea; Kolias, Angelos G.; Hutchinson, Peter J.; Brady, Ken M.; Menon, David K.; Pickard, John D.; Smielewski, Peter

    Objectives: We have sought to develop an automated methodology for the continuous updating of optimal cerebral perfusion pressure (CPPopt) for patients after severe traumatic head injury, using continuous monitoring of cerebrovascular pressure reactivity. We then validated the CPPopt algorithm by

  6. Myocardial imaging by direct injection of thallium-201 into coronary artery

    International Nuclear Information System (INIS)

    Sugihara, Hiroki; Inagaki, Suetsugu; Kubota, Yasushi

    1988-01-01

    Myocardial perfusion images were evaluated by direct injection of Thallium (Tl)-201 into coronary artery. Approximately 0.5 - 1 mCi of Tl-201 were instilled into the right coronary artery and/or the left coronary artery after coronary arteriography. Three images were obtained in the anterior, left anterior oblique and left lateral projections. Myocardial perfusion images of single photon emission computed tomography were also acquired in some patients. An image of supreme quality could be obtained in spite of small dose of Tl-201 since there was a lack of interference from background activity. Myocardial perfusion images corresponded to areas which were supplied by left or right coronary artery respectively. And the regional myocardial blood flow distribution of a coronary artery bypass graft could be revealed by instilling Tl-201 into the graft. Further, contribution of collateral channels to myocardial perfusion was showed. Not only left ventricle but also right ventricle was clearly visualized by injection of Tl-201 into right coronary artery. But in a case with arrhythmogenic right ventricular dysplasia, there was an area of decreased tracer uptake in the apex of the right ventricle which was identified as the site of dysplasia by electrophysiologic study. We conclude that direct injection of Tl-201 into coronary artery is an useful method to clarify the correlation between coronary anatomical findings and coronary perfusion and contribution of collaterals to myocardial perfusion, and also to detect the right ventricular myopathic site. (author)

  7. Prevalence of symptomatic and silent stress-induced perfusion defects in diabetic patients with suspected coronary artery disease referred for myocardial perfusion scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Prior, John O.; Calcagni, Maria-Lucia; Bischof Delaloye, Angelika [Centre Hospitalier Universitaire Vaudois (CHUV University Hospital), Division of Nuclear Medicine, Lausanne (Switzerland); Monbaron, David; Ruiz, Juan [Centre Hospitalier Universitaire Vaudois (CHUV University Hospital), Division of Endocrinology, Diabetology and Metabolism, Lausanne (Switzerland); Koehli, Melanie [Centre Hospitalier Universitaire Vaudois (CHUV University Hospital), Division of Nuclear Medicine, Lausanne (Switzerland); Centre Hospitalier Universitaire Vaudois (CHUV University Hospital), Division of Endocrinology, Diabetology and Metabolism, Lausanne (Switzerland)

    2005-01-01

    Silent myocardial ischaemia - as evaluated by stress-induced perfusion defects on myocardial perfusion scintigraphy (MPS) in patients without a history of chest pain - is frequent in diabetes and is associated with increased rates of cardiovascular events. Its prevalence has been determined in asymptomatic diabetic patients, but remains largely unknown in diabetic patients with suspected coronary artery disease (CAD) in the clinical setting. In this study we therefore sought (a) to determine the prevalence of symptomatic and silent perfusion defects in diabetic patients with suspected CAD and (b) to characterise the eventual predictors of abnormal perfusion. The patient population comprised 133 consecutive diabetic patients with suspected CAD who had been referred for MPS. Studies were performed with exercise (41%) or pharmacological stress testing (1-day protocol, {sup 99m}Tc-sestamibi, {sup 201}Tl or both). We used semi-quantitative analysis (20-segment polar maps) to derive the summed stress score (SSS) and the summed difference score (SDS). Abnormal MPS (SSS{>=}4) was observed in 49 (37%) patients (SSS=4.9{+-}8.4, SDS=2.4{+-}4.7), reversible perfusion defects (SDS{>=}2) in 40 (30%) patients [SSS=13.3{+-}10.9; SDS=8.0{+-}5.6; 20% moderate to severe (SDS>4), 7% multivessel] and fixed defects in 21 (16%) patients. Results were comparable between patients with and patients without a history of chest pain. Of 75 patients without a history of chest pain, 23 (31%, 95% CI=21-42%) presented reversible defects (SSS=13.9{+-}11.3; SDS=7.4{+-}1.2), indicative of silent ischaemia. Reversible defects were associated with inducible ST segment depression during MPS stress (odds ratio (OR)=3.2, p<0.01). Fixed defects were associated with erectile dysfunction in males (OR=3.7, p=0.02) and lower aspirin use (OR=0.25, p=0.02). Silent stress-induced perfusion defects occurred in 31% of the patients, a rate similar to that in patients with a history of chest pain. MPS could identify

  8. Quantification of myocardial perfusion SPECT for the assessment of coronary artery disease: should we apply scatter correction?

    International Nuclear Information System (INIS)

    Hambye, A.S.; Vervaet, A.; Dobbeleir, A.

    2002-01-01

    Compared to other non invasive testings for CAD diagnosis, myocardial perfusion imaging (MPI) is considered as a very sensitive method which accuracy is however often dimmed by a certain lack of specificity, especially in patients with a small heart. With gated SPECT MPI, use of end-diastolic instead of summed images has been presented as an interesting approach for increasing specificity. Since scatter correction is reported to improve image contrast, it might potentially constitute another way to ameliorate MPI accuracy. We aimed at comparing the value of both approaches, either separate or combined, for CAD diagnosis. Methods. Hundred patients addressed for gated 99m-Tc sestamibi SPECT MPI were prospectively included (Group A). Thirty-five had an end-systolic volume <30ml by QGS-analysis (Group B). All had a coronary angiogram within 3 months of the MPI. Four polar maps (non-corrected and scatter-corrected summed, and non-corrected and scatter-corrected end-diastolic) were created to quantify the extent (EXT) and severity (TDS) of the perfusion defects if any. ROC-curve analysis was applied to define the optimal thresholds of EXT and TDS separating non-CAD from CAD-patients, using a 50%-stenosis on coronary angiogram as cutoff for disease positivity. Results. Significant CAD was present in 86 patients (25 in Group B). In Group A, assessment of EXT and TDS of perfusion defects on scatter-corrected summed images demonstrated the highest accuracy (76% for EXT; sens: 77%; spec: 71%, and 74% for TDS, sens: 73%, spec: 79%). Accuracy of EXT and TDS calculated from the other data sets was slightly but not significantly lower, especially because of a lower sensitivity. As a comparison, visual analysis was 90% accurate for the diagnosis of CAD (sens: 94%, spec: 64%). In group B, overall results were worse mainly due to a decreased sensitivity, with accuracies ranging between 51 and 63%. Again scatter-corrected summed data were the most accurate (EXT: 60%, TDS: 63%, visual

  9. The minimum coronary artery diameter in which coronary spasm can be identified by synchrotron radiation coronary angiography

    International Nuclear Information System (INIS)

    Matsushita, Shonosuke; Hyodo, Kazuyuki; Imazuru, Tomohiro; Tokunaga, Chiho; Sato, Fujio; Enomoto, Yoshiharu; Hiramatsu, Yuji; Sakakibara, Yuzuru

    2008-01-01

    Background: Coronary vasospasm is defined as a temporary, intense narrowing of the coronary conduit artery. It brings about ischemic chest pain and becomes one of the causes of myocardial infarction. Coronary spasms are divided into two categories. One is the coronary spasm of the conduit artery and the other is the coronary microvascular spasm. Although coronary spasms are diagnosed with the images of coronary angiography, microvascular spasms cannot be diagnosed because of the limitations of conventional angiographic systems. However, synchrotron radiation coronary angiography (SRCA) can identify coronary arteries down to 100 μm in diameter in the beating heart and 50 μm in arrested heart. Aim: The purpose of this study was to confirm whether microvascular spasms could be identified or not using SRCA, and then down that size identification was possible. Methods: The Langendorff perfusion system with isolated rat hearts was employed. Krebs-Henseleit solution (KH solution) was used as a perfusate. 10 mM of 4-aminopyridine (4-AP: a voltage-gated potassium channel blocker; spasm inducer) was added to the KH solution and maintained for 5 min. SRCA was performed at pre-, during and 10 min after cessation of the KH solution with 4-AP. Coronary spasms were defined as a temporal 75% reduction of coronary arterial diameter. Results and conclusion: Multiple sizes of coronary arteries showed coronary spasms. The minimum stenosed coronary artery size was 100 μm. Since coronary microvascular spasms are seen in the arterioles (50-400 μm), coronary microvascular spasms may be diagnosed with the use of synchrotron radiation coronary angiography

  10. Thallium-201 myocardial imaging during coronary vasodilation induced by oral dipyridamole

    International Nuclear Information System (INIS)

    Gould, K.L.; Sorenson, S.G.; Albro, P.; Caldwell, J.H.; Chaudhuri, T.; Hamilton, G.W.

    1986-01-01

    Myocardial perfusion imaging of 201 TI injected during maximum exercise has been an important diagnostic tool for coronary artery disease. Pharmacologic coronary vasodilation by i.v. infusion of dipyridamole may be used in lieu of exercise stress for purposes of diagnostic perfusion imaging. However, i.v. dipyridamole is not currently available from commercial sources for widespread routine use. Accordingly, this study was carried out in order to determine whether high dose, oral dipyridamole would be useful as a coronary vasodilator for purposes of diagnostic perfusion imaging. Fifty-eight patients undergoing diagnostic coronary arteriography also had myocardial perfusion imaging with 201TI under conditions of rest, maximum exercise stress, and high dose oral dipyridamole. Of those patients who had a defect on exercise thallium images, 75% also had a perfusion defect on thallium images after high dose oral dipyridamole. These results indicate that oral dipyridamole causes sufficient coronary arteriolar vasodilation and increase of coronary flow in nonstenotic arteries to identify perfusion defects comparable to those seen on maximum exercise stress in at least 75% of cases. In 25% of patients with exercise defects, no perfusion defect was seen after oral dipyridamole. Thus, oral dipyridamole is a potent coronary vasodilator, comparable to exercise stress in most cases, but in a minority of patients may not be comparable to exercise stress

  11. Regulation of Coronary Blood Flow in Health and Ischemic Heart Disease

    Science.gov (United States)

    Duncker, Dirk J.; Koller, Akos; Merkus, Daphne; Canty, John M.

    2018-01-01

    The major factors determining myocardial perfusion and oxygen delivery have been elucidated over the past several decades, and this knowledge has been incorporated into the management of patients with ischemic heart disease (IHD). The basic understanding of the fluid mechanical behavior of coronary stenoses has also been translated to the cardiac catheterization laboratory where measurements of coronary pressure distal to a stenosis and coronary flow are routinely obtained. However, the role of perturbations in coronary microvascular structure and function, due to myocardial hypertrophy or coronary microvascular dysfunction, in IHD is becoming increasingly recognized. Future studies should therefore be aimed at further improving our understanding of the integrated coronary microvascular mechanisms that control coronary blood flow, and of the underlying causes and mechanisms of coronary microvascular dysfunction. This knowledge will be essential to further improve the treatment of patients with IHD. PMID:25475073

  12. Diagnostic value of myocardial perfusion SPECT in the prediction of restenosis after coronary artery bypass graft surgery

    International Nuclear Information System (INIS)

    Paeng, J. C.; Lee, D. S.; Kang, W. J.; Kim, K. B.; Chung, J. K.; Lee, M. C.

    2002-01-01

    Myocardial SPECT has been reported to be sensitive in the detection of restenosis after revascularization. However, the diagnostic value is not well established in bypass graft surgery (CABG), due to significant influences of characteristics of graft vessels and the time interval between CABG and the SPECT. In this study, we evaluated the diagnostic value of myocardial SPECT for the restenosis after CABG. A total of 160 patients with coronary artery disease (M:F=118:42, 60±8 yr) who had undergone CABG were included. Rest T1-201/ dipyridamole stress Tc-99m-MIBI SPECT was performed 3 months (103±16 days) after CABG. Segmental perfusion was quantified using a 20-segment model, and segments of reversible perfusion defect (REV) were defined. Follow-up coronary angiography was performed 1 year (397±104 days) after CABG. The segments of REV were compared between arterial and venous graft groups. And the diagnostic power of 3-month SPECT was evaluated for the prediction of restenosis. On the 3-month SPECT, 620 segments showed REV. The segments of REV were 37% of artery-grafted segments and 36% of vein-grafted segments (p=n.s.). On 1-year coronary angiography, 113 graft vessels (28%) showed restenosis. The overall sensitivity and specificity of REV on 3-month SPECT for the prediction of restenosis were 46% and 67%, respectively, but 52% and 68%, in artery-graft group. REV detected on 3-month SPECT has a predictive value, especially, high specificity for the prediction of restenosis after CABG, which was more definite in artery-graft group

  13. Effect of atrial systole on canine and porcine coronary blood flow.

    Science.gov (United States)

    Bellamy, R F

    1981-09-01

    A feature of phasic coronary flow patterns recorded in conscious chronically instrumented dogs is the atrial cove--a transient depression of arterial flow that occurs during atrial systole. The association between the hemodynamic effects of atrial systole and the atrial cove was studied in anesthetized dogs and pigs with complete heart block. Many atrial coves are available for study in these preparations because atrial activity continues unabated during the diastolic ventricular arrest that follows cessation of electrical pacing. The effect of atrial systole is to translate the pressure-flow relation found during diastole to a higher intercept pressure without change in slope. The increase in the intercept pressure equals the increase in intramyocardial pressure measured with microtransducers embedded in the left ventricular wall. The decrement in flow during the atrial cove is a direct function of the change in intramyocardial pressure and an inverse function of coronary vascular resistance. Each atrial systole is associated with a forward flow transient in the coronary veins, the peak of which occurs at the same instant as does the nadir of atrial flow. These data suggest that the coronary vessels are acting as collapsible tubes and that the waterfall model of the coronary circulation is applicable. The following sequence is proposed to account for the atrial cove. Atrial systole ejects a bolus of blood into the left ventricle increasing both ventricular cavity and intramyocardial pressures. The increase in intramyocardial pressure raises the back pressure opposing coronary flow, reducing the arterial perfusion pressure gradient and causing flow to fall.

  14. Myocardial perfusion magnetic resonance imaging using sliding-window conjugate-gradient highly constrained back-projection reconstruction for detection of coronary artery disease.

    Science.gov (United States)

    Ma, Heng; Yang, Jun; Liu, Jing; Ge, Lan; An, Jing; Tang, Qing; Li, Han; Zhang, Yu; Chen, David; Wang, Yong; Liu, Jiabin; Liang, Zhigang; Lin, Kai; Jin, Lixin; Bi, Xiaoming; Li, Kuncheng; Li, Debiao

    2012-04-15

    Myocardial perfusion magnetic resonance imaging (MRI) with sliding-window conjugate-gradient highly constrained back-projection reconstruction (SW-CG-HYPR) allows whole left ventricular coverage, improved temporal and spatial resolution and signal/noise ratio, and reduced cardiac motion-related image artifacts. The accuracy of this technique for detecting coronary artery disease (CAD) has not been determined in a large number of patients. We prospectively evaluated the diagnostic performance of myocardial perfusion MRI with SW-CG-HYPR in patients with suspected CAD. A total of 50 consecutive patients who were scheduled for coronary angiography with suspected CAD underwent myocardial perfusion MRI with SW-CG-HYPR at 3.0 T. The perfusion defects were interpreted qualitatively by 2 blinded observers and were correlated with x-ray angiographic stenoses ≥50%. The prevalence of CAD was 56%. In the per-patient analysis, the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of SW-CG-HYPR was 96% (95% confidence interval 82% to 100%), 82% (95% confidence interval 60% to 95%), 87% (95% confidence interval 70% to 96%), 95% (95% confidence interval 74% to100%), and 90% (95% confidence interval 82% to 98%), respectively. In the per-vessel analysis, the corresponding values were 98% (95% confidence interval 91% to 100%), 89% (95% confidence interval 80% to 94%), 86% (95% confidence interval 76% to 93%), 99% (95% confidence interval 93% to 100%), and 93% (95% confidence interval 89% to 97%), respectively. In conclusion, myocardial perfusion MRI using SW-CG-HYPR allows whole left ventricular coverage and high resolution and has high diagnostic accuracy in patients with suspected CAD. Copyright © 2012 Elsevier Inc. All rights reserved.

  15. An open-source framework of neural networks for diagnosis of coronary artery disease from myocardial perfusion SPECT.

    Science.gov (United States)

    Guner, Levent A; Karabacak, Nese Ilgin; Akdemir, Ozgur U; Karagoz, Pinar Senkul; Kocaman, Sinan A; Cengel, Atiye; Unlu, Mustafa

    2010-06-01

    The purpose of this study is to develop and analyze an open-source artificial intelligence program built on artificial neural networks that can participate in and support the decision making of nuclear medicine physicians in detecting coronary artery disease from myocardial perfusion SPECT (MPS). Two hundred and forty-three patients, who had MPS and coronary angiography within three months, were selected to train neural networks. Six nuclear medicine residents, one experienced nuclear medicine physician, and neural networks evaluated images of 65 patients for presence of coronary artery stenosis. Area under the curve (AUC) of receiver operating characteristics analysis for networks and expert was .74 and .84, respectively. The AUC of the other physicians ranged from .67 to .80. There were no significant differences between expert, neural networks, and standard quantitative values, summed stress score and total stress defect extent. The open-source neural networks developed in this study may provide a framework for further testing, development, and integration of artificial intelligence into nuclear cardiology environment.

  16. Effect of Coronary Anatomy and Hydrostatic Pressure on Intracoronary Indices of Stenosis Severity.

    Science.gov (United States)

    Härle, Tobias; Luz, Mareike; Meyer, Sven; Kronberg, Kay; Nickau, Britta; Escaned, Javier; Davies, Justin; Elsässer, Albrecht

    2017-04-24

    The authors sought to analyze height differences within the coronary artery tree in patients in a supine position and to quantify the impact of hydrostatic pressure on intracoronary pressure measurements in vitro. Although pressure equalization of the pressure sensor and the systemic pressure at the catheter tip is mandatory in intracoronary pressure measurements, subsequent measurements may be influenced by hydrostatic pressure related to the coronary anatomy in the supine position. Outlining and quantifying this phenomenon is important to interpret routine and pullback pressure measurements within the coronary tree. Coronary anatomy was analyzed in computed tomography angiographies of 70 patients to calculate height differences between the catheter tip and different coronary segments in the supine position. Using a dynamic pressure simulator, the effect of the expected hydrostatic pressure resulting from such height differences on indices stenosis severity was assessed. In all patients, the left anterior and right posterior descending arteries are the highest points of the coronary tree with a mean height difference of -4.9 ± 1.6 cm and -3.8 ± 1.0 cm; whereas the circumflex artery and right posterolateral branches are the lowest points, with mean height differences of 3.9 ± 0.9 cm and 2.6 ± 1.6 cm compared with the according ostium. In vitro measurements demonstrated a correlation of the absolute pressure differences with height differences (r = 0.993; p pressure level. Hydrostatic pressure variations resulting from normal coronary anatomy in a supine position influence intracoronary pressure measurements and may affect their interpretation during stenosis severity assessment. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  17. Ventricular distension and diastolic coronary blood flow in the anaesthetized dog.

    Science.gov (United States)

    Gattullo, D; Linden, R J; Losano, G; Pagliaro, P; Westerhof, N

    1993-01-01

    There appears to be no agreement as to whether or not an increase in diastolic left ventricular pressure and/or volume can cause a decrease in diastolic coronary blood flow. We investigated the problem in the anaesthetized dog using a flaccid freely distensible latex balloon inserted into the left ventricle with the animal on extracorporeal circulation and the coronary perfusion pressure constant at about 45 mm Hg. Maximal vasodilatation and suppression of autoregulation in coronary vasculature was obtained by the intracoronary infusion of dipyridamole (10-40 mg/h). Ventricular volume was changed in steps of 10 ml from 10 to 70 ml and back to 10 ml, whilst recording coronary blood flow and left ventricular pressure in the left circumflex coronary artery. Over a range of ventricular volumes from 20 to 50 ml and a concomitant rise in diastolic ventricular pressure to about 20 mm Hg there was no change in the diastolic coronary flow. Only when the ventricular volume was more than two times the control value (i.e. exceeded 50 ml) and left ventricular pressure was more than 20 mm Hg, was there a decrease in coronary flow. During the return of the volume to the control level there was a fall in diastolic flow and ventricular contractility with respect to the values obtained when the volume was increased; these two effects were transient lasting less than 10 min. It was not considered that any of the three models of the coronary circulation, waterfall, intramyocardial pump or varying elastance model could explain our results.(ABSTRACT TRUNCATED AT 250 WORDS)

  18. Simultaneous assessment of myocardial perfusion and function during mental stress in patients with chronic coronary artery disease.

    Science.gov (United States)

    Arrighi, James A; Burg, Matthew; Cohen, Ira S; Soufer, Robert

    2003-01-01

    Mental stress (MS) is an important provocateur of myocardial ischemia in many patients with chronic coronary artery disease. The majority of laboratory assessments of ischemia in response to MS have included measurements of either myocardial perfusion or function alone. We performed this study to determine the relationship between alterations in perfusion and ventricular function during MS. Methods and results Twenty-eight patients with reversible perfusion defects on exercise or pharmacologic stress myocardial perfusion imaging (MPI) underwent simultaneous technetium 99m sestamibi single photon emission computed tomography (SPECT) MPI and transthoracic echocardiography at rest and during MS according to a mental arithmetic protocol. In all cases the MS study was performed within 4 weeks of the initial exercise or pharmacologic MPI that demonstrated ischemia. SPECT studies were analyzed visually with the use of a 13-segment model and quantitatively by semiautomated circumferential profile analysis. Echocardiograms were graded on a segmental model for regional wall motion on a 4-point scale. Of 28 patients, 18 (64%) had perfusion defects and/or left ventricular dysfunction develop during MS: 9 (32%) had myocardial perfusion defects develop, 6 (21%) had regional or global left ventricular dysfunction develop, and 3 (11%) had both perfusion defects and left ventricular dysfunction develop. The overall concordance between perfusion and function criteria for ischemia during MS was only 46%. Among 9 patients with MS-induced left ventricular dysfunction, 5 had new regional wall motion abnormalities and 4 had a global decrement in function. In patients with MS-induced ischemia by SPECT, the number of reversible perfusion defects was similar during both MS and exercise/pharmacologic stress (2.8 +/- 2.0 vs 3.5 +/- 1.8, P =.41). Hemodynamic changes during MS were similar whether patients were divided on the basis of perfusion defects or left ventricular dysfunction during MS

  19. Impaired coronary flow reserve is the most important marker of viable myocardium in the myocardial segment-based analysis of dual-isotope gated myocardial perfusion single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Lee, Won Woo; So, Young; Kim, Ki Bong; Lee, Dong Soo

    2014-01-01

    The aim of this study was to investigate the most robust predictor of myocardial viability among stress/rest reversibility (coronary flow reserve [CFR] impairment), 201 Tl perfusion status at rest, 201 Tl 24 hours redistribution and systolic wall thickening of 99m Tc-methoxyisobutylisonitrile using a dual isotope gated myocardial perfusion single-photon emission computed tomography (SPECT) in patients with coronary artery disease (CAD) who were re-vascularized with a coronary artery bypass graft (CABG) surgery. A total of 39 patients with CAD was enrolled (34 men and 5 women), aged between 36 and 72 years (mean 58 ± 8 standard in years) who underwent both pre- and 3 months post-CABG myocardial SPECT. We analyzed 17 myocardial segments per patient. Perfusion status and wall motion were semi-quantitatively evaluated using a 4-point grading system. Viable myocardium was defined as dysfunctional myocardium which showed wall motion improvement after CABG. The left ventricular ejection fraction (LVEF) significantly increased from 37.8 ± 9.0% to 45.5 ± 12.3% (p 201 Tl rest perfusion status (p = 0.024) were significant predictors of wall motion improvement. However, in multiple logistic regression analysis, stress/rest reversibility alone was a significant predictor for post-CABG wall motion improvement (p < 0.001). Stress/rest reversibility (impaired CFR) during dual-isotope gated myocardial perfusion SPECT was the single most important predictor of wall motion improvement after CABG.

  20. Prospective assessment of regional myocardial perfusion before and after coronary revascularization surgery by quantitative thallium-201 scintigraphy

    International Nuclear Information System (INIS)

    Gibson, R.S.; Watson, D.D.; Taylor, G.J.; Crosby, I.K.; Wellons, H.L.; Holt, N.D.; Beller, G.A.

    1983-01-01

    Because thallium-201 uptake relates directly to the amount of viable myocardium and nutrient blood flow, the potential for exercise scintigraphy to predict response to coronary revascularization surgery was investigated in 47 consecutive patients. All patients underwent thallium-201 scintigraphy and coronary angiography at a mean (+/- standard deviation) of 4.3 +/- 3.1 weeks before and 7.5 +/- 1.6 weeks after surgery. Thallium uptake and washout were computer-quantified and each of six segments was defined as normal, showing total or partial redistribution or a persistent defect. Persistent defects were further classified according to the percent reduction in regional thallium activity; PD25-50 denoted a 25 to 50% constant reduction in relative thallium activity and PD greater than 50 denoted a greater than 50% reduction. Of 82 segments with total redistribution before surgery, 76 (93%) showed normal thallium uptake and washout postoperatively, versus only 16 (73%) of 22 with partial redistribution (probability [p] . 0.01). Preoperative ventriculography revealed that 95% of the segments with total redistribution had preserved wall motion, versus only 74% of those with partial redistribution (p . 0.01). Of 42 persistent defects thought to represent myocardial scar before surgery, 19 (45%) demonstrated normal perfusion postoperatively. Of the persistent defects that showed improved thallium perfusion postoperatively, 75% had normal or hypokinetic wall motion before surgery, versus only 14% of those without improvement (p less than 0.001). Whereas 57% of the persistent defects that showed a 25 to 50% decrease in myocardial activity demonstrated normal thallium uptake and washout postoperatively, only 21% of the persistent defects with a decrease in myocardial activity greater than 50% demonstrated improved perfusion after surgery (p . 0.02)

  1. Incremental value of contrast myocardial perfusion to detect intermediate versus severe coronary artery stenosis during stress-echocardiography

    Directory of Open Access Journals (Sweden)

    Ugo Fabrizio

    2010-05-01

    Full Text Available Abstract Background We aimed to compare the incremental value of contrast myocardial perfusion imaging (MPI for the detection of intermediate versus severe coronary artery stenosis during dipyridamole-atropine echocardiography (DASE. Wall motion (WM assessment during stress-echocardiography demonstrates suboptimal sensitivity to detect coronary artery disease (CAD, particularly in patients with isolated intermediate (50%-70% coronary stenosis. Methods We performed DASE with MPI in 150 patients with a suspected chest pain syndrome who were given clinical indication to coronary angiography. Results and discussion When CAD was defined as the presence of a ≥50% stenosis, the addition of MPI increased sensitivity (+30% and decreased specificity (-14%, with a final increase in total diagnostic accuracy (+16%, p Conclusions The addition of MPI on top of WM analysis during DASE increases the diagnostic sensitivity to detect obstructive CAD, whatever its definition (≥50% or > 70% stenosis, but it is mainly driven by the sensitivity increase in the intermediate group (50%-70% stenosis. The total diagnostic accuracy increased only when defining CAD as ≥50% stenosis, since in patients with severe stenosis (> 70% the decrease in specificity is not counterbalanced by the minor sensitivity increase.

  2. Hydrostatic determinants of cerebral perfusion

    International Nuclear Information System (INIS)

    Wagner, E.M.; Traystman, R.J.

    1986-01-01

    We examined the cerebral blood flow response to alterations in perfusion pressure mediated through decreases in mean arterial pressure, increases in cerebrospinal fluid (CSF) pressure, and increases in jugular venous (JV) pressure in 42 pentobarbital anesthetized dogs. Each of these three pressures was independently controlled. Cerebral perfusion pressure was defined as mean arterial pressure minus JV or CSF pressure, depending on which was greater. Mean hemispheric blood flow was measured with the radiolabeled microsphere technique. Despite 30-mm Hg reductions in mean arterial pressure or increases in CSF or JV pressure, CBF did not change as long as the perfusion pressure remained greater than approximately 60 mm Hg. However, whenever perfusion pressure was reduced to an average of 48 mm Hg, cerebral blood flow decreased 27% to 33%. These results demonstrate the capacity of the cerebral vascular bed to respond similarly to changes in the perfusion pressure gradient obtained by decreasing mean arterial pressure, increasing JV pressure or increasing CSF pressure, and thereby support the above definition of cerebral perfusion pressure

  3. Prognostic value of Tc-99m tetrofosmin myocardial perfusion gated SPECT in patients with diabetes mellitus and suspected coronary artery disease

    International Nuclear Information System (INIS)

    Santos, Marcia Maria Sales dos; Pantoja, Mauricio da Rocha; Cwajg, Eduardo

    2008-01-01

    Background: The cardiovascular disease is the main cause of death among diabetic patients, which makes it crucial to identify the individuals at higher risk of cardiovascular events. Objective: To evaluate the prognostic value of scintigraphy with gated single photon emission computed tomography (SPECT) in patients with diabetes mellitus (DM) and suspected coronary artery disease. Methods: Retrospective study with 232 diabetic patients submitted to scintigraphy with gated SPECT. Perfusion Gated SPECT (scores and number of altered segments) as well as ventricular function parameters (ejection fraction, left ventricle volume and contractility) were evaluated. Cardiac death, acute ischemic coronary syndrome, revascularization procedures or encephalic vascular accident were considered future cardiovascular events. The uni- and multivariate analyses were carried out by the multiple logistic regression model (p< 0.05). Results: At the univariate analysis, age (p=0.02), chest angina (p=0.01), insulin therapy (p=0.02), myocardial perfusion abnormalities (p<0.0001), the number of segments involved (p=0.0001), the perfusion scores (p=0.0001), the ejection fraction (p=0.004), the final systolic volume (p=0.03) and the finding of segmental alteration at the LV contractility (p<0.0001) were associated with future events at the univariate analysis. At the multivariate analysis, the male sex (p=0.007), age (p=0.03), angina (p=0.001), insulin therapy (p=0.007) and the SDS ≥ 3 (p=0.0001), and the number of altered segments ≥ 3 (p=0.0001) were predictors of cardiovascular events. Conclusion: The myocardial scintigraphy with gated SPECT adds independent information to the stratification of the risk of future cardiovascular events in patients with DM and suspected coronary artery disease. (author)

  4. Prognostic value of Tc-99m tetrofosmin myocardial perfusion gated SPECT in patients with diabetes mellitus and suspected coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Marcia Maria Sales dos; Pantoja, Mauricio da Rocha; Cwajg, Eduardo [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil); CINTILAB, Rio de Janeiro, RJ (Brazil); E-mail: mmsales@oi.com.br

    2008-01-15

    Background: The cardiovascular disease is the main cause of death among diabetic patients, which makes it crucial to identify the individuals at higher risk of cardiovascular events. Objective: To evaluate the prognostic value of scintigraphy with gated single photon emission computed tomography (SPECT) in patients with diabetes mellitus (DM) and suspected coronary artery disease. Methods: Retrospective study with 232 diabetic patients submitted to scintigraphy with gated SPECT. Perfusion Gated SPECT (scores and number of altered segments) as well as ventricular function parameters (ejection fraction, left ventricle volume and contractility) were evaluated. Cardiac death, acute ischemic coronary syndrome, revascularization procedures or encephalic vascular accident were considered future cardiovascular events. The uni- and multivariate analyses were carried out by the multiple logistic regression model (p< 0.05). Results: At the univariate analysis, age (p=0.02), chest angina (p=0.01), insulin therapy (p=0.02), myocardial perfusion abnormalities (p<0.0001), the number of segments involved (p=0.0001), the perfusion scores (p=0.0001), the ejection fraction (p=0.004), the final systolic volume (p=0.03) and the finding of segmental alteration at the LV contractility (p<0.0001) were associated with future events at the univariate analysis. At the multivariate analysis, the male sex (p=0.007), age (p=0.03), angina (p=0.001), insulin therapy (p=0.007) and the SDS {>=} 3 (p=0.0001), and the number of altered segments {>=} 3 (p=0.0001) were predictors of cardiovascular events. Conclusion: The myocardial scintigraphy with gated SPECT adds independent information to the stratification of the risk of future cardiovascular events in patients with DM and suspected coronary artery disease. (author)

  5. Flow regulation in coronary vascular tree: a model study.

    Directory of Open Access Journals (Sweden)

    Xinzhou Xie

    Full Text Available Coronary blood flow can always be matched to the metabolic demand of the myocardium due to the regulation of vasoactive segments. Myocardial compressive forces play an important role in determining coronary blood flow but its impact on flow regulation is still unknown. The purpose of this study was to develop a coronary specified flow regulation model, which can integrate myocardial compressive forces and other identified regulation factors, to further investigate the coronary blood flow regulation behavior.A theoretical coronary flow regulation model including the myogenic, shear-dependent and metabolic responses was developed. Myocardial compressive forces were included in the modified wall tension model. Shear-dependent response was estimated by using the experimental data from coronary circulation. Capillary density and basal oxygen consumption were specified to corresponding to those in coronary circulation. Zero flow pressure was also modeled by using a simplified capillary model.Pressure-flow relations predicted by the proposed model are consistent with previous experimental data. The predicted diameter changes in small arteries are in good agreement with experiment observations in adenosine infusion and inhibition of NO synthesis conditions. Results demonstrate that the myocardial compressive forces acting on the vessel wall would extend the auto-regulatory range by decreasing the myogenic tone at the given perfusion pressure.Myocardial compressive forces had great impact on coronary auto-regulation effect. The proposed model was proved to be consistent with experiment observations and can be employed to investigate the coronary blood flow regulation effect in physiological and pathophysiological conditions.

  6. Correlation between thallium-201 myocardial perfusion defects and the functional severity of coronary artery stenosis as assessed by pressure-derived myocardial fractional flow reserve

    International Nuclear Information System (INIS)

    Yanagisawa, Hidefumi; Chikamori, Taishiro; Tanaka, Nobuhiro

    2002-01-01

    Although a relationship between the coronary pressure-derived fractional flow reserve (FFR) and the presence of myocardial ischemia as demonstrated by radionuclide imaging has been reported in a select group of patients, it remains to be established whether this relation also holds true in actual clinical settings with a heterogeneous group of patients. Accordingly, 194 coronary vessels and their supply territories were evaluated in 165 consecutive patients with suspected or known coronary artery disease. An FFR 201 Tl (p 201 Tl reversibility score (r=-0.62; p<0.0001). These results suggest that the FFR has a significant relationship with scintigraphic evidence of myocardial ischemia and can be regarded as a marker of its presence or absence in patients in actual clinical settings. (author)

  7. A database for estimating organ dose for coronary angiography and brain perfusion CT scans for arbitrary spectra and angular tube current modulation

    International Nuclear Information System (INIS)

    Rupcich, Franco; Badal, Andreu; Kyprianou, Iacovos; Schmidt, Taly Gilat

    2012-01-01

    Purpose: The purpose of this study was to develop a database for estimating organ dose in a voxelized patient model for coronary angiography and brain perfusion CT acquisitions with any spectra and angular tube current modulation setting. The database enables organ dose estimation for existing and novel acquisition techniques without requiring Monte Carlo simulations. Methods: The study simulated transport of monoenergetic photons between 5 and 150 keV for 1000 projections over 360° through anthropomorphic voxelized female chest and head (0° and 30° tilt) phantoms and standard head and body CTDI dosimetry cylinders. The simulations resulted in tables of normalized dose deposition for several radiosensitive organs quantifying the organ dose per emitted photon for each incident photon energy and projection angle for coronary angiography and brain perfusion acquisitions. The values in a table can be multiplied by an incident spectrum and number of photons at each projection angle and then summed across all energies and angles to estimate total organ dose. Scanner-specific organ dose may be approximated by normalizing the database-estimated organ dose by the database-estimated CTDI vol and multiplying by a physical CTDI vol measurement. Two examples are provided demonstrating how to use the tables to estimate relative organ dose. In the first, the change in breast and lung dose during coronary angiography CT scans is calculated for reduced kVp, angular tube current modulation, and partial angle scanning protocols relative to a reference protocol. In the second example, the change in dose to the eye lens is calculated for a brain perfusion CT acquisition in which the gantry is tilted 30° relative to a nontilted scan. Results: Our database provides tables of normalized dose deposition for several radiosensitive organs irradiated during coronary angiography and brain perfusion CT scans. Validation results indicate total organ doses calculated using our database are

  8. Added Value of 3D Cardiac SPECT/CTA Fusion Imaging in Patients with Reversible Perfusion Defect on Myocardial Perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kong, Eun Jung; Cho, Ihn Ho [Yeungnam University Hospital, Daegu (Korea, Republic of); Kang, Won Jun [Yonsei University Hospital, Seoul (Korea, Republic of); Kim, Seong Min [Chungnam National University Medical School and Hospital, Daejeon (Korea, Republic of); Won, Kyoung Sook [Keomyung University Dongsan Hospital, Daegu (Korea, Republic of); Lim, Seok Tae [Chonbuk National University Medical School and Hospital, Jeonju (Korea, Republic of); Hwang, Kyung Hoon [Gachon University Gil Hospital, Incheon (Korea, Republic of); Lee, Byeong Il; Bom, Hee Seung [Chonnam National University Medical School and Hospital, Gwangju (Korea, Republic of)

    2009-12-15

    Integration of the functional information of myocardial perfusion SPECT (MPS) and the morphoanatomical information of coronary CT angiography (CTA) may provide useful additional diagnostic information of the spatial relationship between perfusion defects and coronary stenosis. We studied to know the added value of three dimensional cardiac SPECT/CTA fusion imaging (fusion image) by comparing between fusion image and MPS. Forty-eight patients (M:F=26:22, Age: 63.3{+-}10.4 years) with a reversible perfusion defect on MPS (adenosine stress/rest SPECT with Tc-99m sestamibi or tetrofosmin) and CTA were included. Fusion images were molded and compared with the findings from the MPS. Invasive coronary angiography served as a reference standard for fusion image and MPS. Total 144 coronary arteries in 48 patients were analyzed; Fusion image yielded the sensitivity, specificity, negative and positive predictive value for the detection of hemodynamically significant stenosis per coronary artery 82.5%, 79.3%, 76.7% and 84.6%, respectively. Respective values for the MPS were 68.8%, 70.7%, 62.1% and 76.4%. And fusion image also could detect more multi-vessel disease. Fused three dimensional volume-rendered SPECT/CTA imaging provides intuitive convincing information about hemodynamic relevant lesion and could improved diagnostic accuracy.

  9. Sodium addition and/or oxygen saturation of iohexol during normal and reduced perfusion pressure

    International Nuclear Information System (INIS)

    Baath, L.

    1990-01-01

    The influence on contractile force (CF) and the propensity for ventricular fibrillation (VF) from infusing the non-ionic contrast medium iohexol during normal (75 cm H 2 O) and reduced perfusion pressure (35 cm H 2 O) were investigated in the isolated rabbit heart. Both during normal and reduced perfusion pressure iohexol (150 mg I/ml) with oxygen saturation caused a smaller reduction of CF than iohexol without oxygen. During reduced pressure iohexol with sodium addition (28 mM NaCl) caused less depression of CF than iohexol without sodium. The combination of sodium addition and oxygen saturation had the least influence on CF. Iohexol (350 mg I/ml) without sodium had a similar fibrillatory propensity during both normal and reduced pressure. Enriching iohexol with 28 mM NaCl decreased the risk of VF. The decrease was similar during both normal and reduced pressure. The risk of VF from oxygen saturation of iohexol (350 mg I/ml, without sodium) was similar during both normal and reduced pressure. It is concluded that a small addition of sodium and/or oxygen saturation of a non-ionic monomeric contrast medium have beneficial effects on the heart both during normal perfusion pressure and during ischemia. (orig.)

  10. Coronary hemodynamics in vasospastic angina

    International Nuclear Information System (INIS)

    Matsumura, Kentaro; Kubota, Shinobu; Serizawa, Takashi; Nakase, Emiko; Kawai, Ichiro; Saito, Takayuki

    1991-01-01

    To evaluate the coronary circulation and myocardial perfusion dynamics, we performed left coronary digital subtraction angiography (DSA) in 35 patients with vasospastic angina. The left coronary circulation time (CCT) measured from the proximal left coronary artery to the coronary sinus was 5.77±0.86 sec, and the left epicardial conducting artery transmission time (CAT) measured from the proximal left coronary artery to the apical area was 2.65±0.82 sec in normal controls. The CCT and CAT were significantly prolonged in patients with vasospastic angina, indicating that the coronary peripheral vascular resistance is probably greater after the cessation of nitrates and Ca ++ -antagonists. After the intracoronary injection of ergonovine malate, the CCT was slightly shortened, but the apical T 1/2 was significantly prolonged in patients with vasospastic angina. This suggested that coronary vasospasm is present not only in the epicardial arteries but also in coronary arteries with peripheral resistance. These phenomena were not observed in normal controls. We performed left coronary DSA after conventional left coronary cineangiography. When the CCT exceeded 6.7 sec, we considered that the coronary circulation was significantly impaired. We concluded that the coronary DSA is very useful for evaluating abnormal coronary circulation in patients with vasospastic angina during myocardial perfusion. (author)

  11. Prevalence of symptomatic and silent stress-induced perfusion defects in diabetic patients with suspected coronary artery disease referred for myocardial perfusion scintigraphy

    International Nuclear Information System (INIS)

    Prior, John O.; Calcagni, Maria-Lucia; Bischof Delaloye, Angelika; Monbaron, David; Ruiz, Juan; Koehli, Melanie

    2005-01-01

    Silent myocardial ischaemia - as evaluated by stress-induced perfusion defects on myocardial perfusion scintigraphy (MPS) in patients without a history of chest pain - is frequent in diabetes and is associated with increased rates of cardiovascular events. Its prevalence has been determined in asymptomatic diabetic patients, but remains largely unknown in diabetic patients with suspected coronary artery disease (CAD) in the clinical setting. In this study we therefore sought (a) to determine the prevalence of symptomatic and silent perfusion defects in diabetic patients with suspected CAD and (b) to characterise the eventual predictors of abnormal perfusion. The patient population comprised 133 consecutive diabetic patients with suspected CAD who had been referred for MPS. Studies were performed with exercise (41%) or pharmacological stress testing (1-day protocol, 99m Tc-sestamibi, 201 Tl or both). We used semi-quantitative analysis (20-segment polar maps) to derive the summed stress score (SSS) and the summed difference score (SDS). Abnormal MPS (SSS≥4) was observed in 49 (37%) patients (SSS=4.9±8.4, SDS=2.4±4.7), reversible perfusion defects (SDS≥2) in 40 (30%) patients [SSS=13.3±10.9; SDS=8.0±5.6; 20% moderate to severe (SDS>4), 7% multivessel] and fixed defects in 21 (16%) patients. Results were comparable between patients with and patients without a history of chest pain. Of 75 patients without a history of chest pain, 23 (31%, 95% CI=21-42%) presented reversible defects (SSS=13.9±11.3; SDS=7.4±1.2), indicative of silent ischaemia. Reversible defects were associated with inducible ST segment depression during MPS stress (odds ratio (OR)=3.2, p<0.01). Fixed defects were associated with erectile dysfunction in males (OR=3.7, p=0.02) and lower aspirin use (OR=0.25, p=0.02). Silent stress-induced perfusion defects occurred in 31% of the patients, a rate similar to that in patients with a history of chest pain. MPS could identify these patients with a

  12. Posttraumatic Stress Disorder Disturbs Coronary Tone and Its Regulatory Mechanisms.

    Science.gov (United States)

    Lazuko, Svetlana S; Kuzhel, Olga P; Belyaeva, Lyudmila E; Manukhina, Eugenia B; Fred Downey, H; Tseilikman, Olga B; Komelkova, Maria V; Tseilikman, Vadim E

    2018-01-01

    Posttraumatic stress disorder (PTSD) is associated with myocardial injury, but changes in coronary regulatory mechanisms in PTSD have not been investigated. This study evaluated the effect of PTSD-inducing stress on coronary tone and its regulation by nitric oxide (NO) and voltage-gated K + channels. PTSD was induced by exposing rats to predator stress, 15 min daily for 10 days, followed by 14 stress-free days. Presence of PTSD was confirmed by the elevated plus-maze test. Coronary tone was evaluated from changes in coronary perfusion pressure of Langendorff isolated hearts. Predator stress induced significant decreases in coronary tone of isolated hearts and in blood pressure of intact rats. L-NAME, a non-selective NO synthase (NOS) inhibitor, but not S-MT, a selective iNOS inhibitor, and increased coronary tone of control rats. In PTSD rats, both L-NAME and S-MT increased coronary tone. Therefore, the stress-induced coronary vasodilation resulted from NO overproduction by both iNOS and eNOS. NOS induction was apparently due to systemic inflammation as evidenced by increased serum interleukin-1β and C-reactive protein in PTSD rats. Decreased corticosterone in PTSD rats may have contributed to inflammation and its effect on coronary tone. PTSD was also associated with voltage-gated K + channel dysfunction, which would have also reduced coronary tone.

  13. Nifedipine and thallium-201 myocardial perfusion in progressive systemic sclerosis

    International Nuclear Information System (INIS)

    Kahan, A.; Devaux, J.Y.; Amor, B.

    1986-01-01

    Heart disease in patients with progressive systemic sclerosis may be due in part to myocardial ischemia caused by a disturbance of the coronary microcirculation. To determine whether abnormalities of myocardial perfusion in this disorder are potentially reversible, we evaluated the effect of the coronary vasodilator nifedipine on myocardial perfusion assessed by thallium-201 scanning in 20 patients. Thallium-201 single-photon-emission computerized tomography was performed under control conditions and 90 minutes after 20 mg of oral nifedipine. The mean (+/- SD) number of left ventricular segments with perfusion defects decreased from 5.3 +/- 2.0 to 3.3 +/- 2.2 after nifedipine (P = 0.0003). Perfusion abnormalities were quantified by a perfusion score (0 to 2.0) assigned to each left ventricular segment and by a global perfusion score (0 to 18) for the entire left ventricle. The mean perfusion score in segments with resting defects increased from 0.97 +/- 0.24 to 1.26 +/- 0.44 after nifedipine (P less than 0.00001). The mean global perfusion score increased from 11.2 +/- 1.7 to 12.8 +/- 2.4 after nifedipine (P = 0.003). The global perfusion score increased by at least 2.0 in 10 patients and decreased by at least 2.0 in only 1. These observations reveal short-term improvement in thallium-201 myocardial perfusion with nifedipine in patients with progressive systemic sclerosis. The results are consistent with a potentially reversible abnormality of coronary vasomotion in this disorder, but the long-term therapeutic effects of nifedipine remain to be determined

  14. Clinical indications for Thallium-201 myocardial perfusion scanning

    International Nuclear Information System (INIS)

    Dunn, R.J.; Kelly, D.T.

    1982-01-01

    Thallium-201 myocardial perfusion scanning can assess regional myocardial perfusion non-invasively. As it is both time-consuming and expensive its use should be restricted to specific diagnostic problems. The clinical indications in known or suspected coronary artery disease are reviewed. In suspected coronary artery disease thallium scanning is most useful in patients with chest pain when the exercise ECG is uninterpretable, in men with probable angina but a negative exercise ECG, or conversely a positive exercise ECG without typical angina, and in women with probable angina and either a positive or a negative exercise ECG. In known coronary artery disease, thallium scanning may help determine the functional significance of a coronary obstruction found at angiography and may determine the site of myocardial ischaemia when multiple obstructions are present

  15. Correlation of angina pectoris and perfusion decrease by collateral circulation in single-vessel coronary chronic total occlusion using myocardial perfusion single-photon emssion computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Sang Geon; Park, Ki Seong; Kang, Sae Ryung [Chonnam National University Hospital, Gwangju (Korea, Republic of); and others

    2016-03-15

    To evaluate the perfusion decrease in donor myocardium by collateral circulation and its correlation with angina pectoris in patients with chronic total occlusion (CTO) using myocardial perfusion single-photon emission computed tomography (MPS). Thirty-six patients with single-vessel CTO without any other stenosis were included. All patients underwent MPS and coronary angiography (CAG) within 2 months. Total 72 donor arteries were evaluated for the grades of collaterals to the CTO artery using the Rentrop grading system on CAG. Perfusion defects and perfusion scores in donor and CTO territories were analyzed on MPS. Myocardial perfusion of donor and CTO territories were evaluated according to the presence of angina pectoris and the grades of collateral circulation. When the CTO territory was ischemic, symptomatic patients showed higher summed difference scores in the CTO territory compared to asymptomatic patients (3.5 ± 2.4 vs. 1.5 ± 0.8 for symptomatic and asymptomatic groups respectively; p = 0.034). However, when the CTO territory was nonischemic, symptomatic patients showed higher summed stress scores (SSS, 4.3 ± 2.9 vs. 1.6 ± 1.2; p = 0.032) and summed rest scores (SRS, 4.2 ± 2.5 vs. 1.5 ± 1.1; p = 0.003) in the donor territories. On the per-vessel analysis, perfusion defects in donor territories were more frequent (0 % vs. 53 % vs. 86 % for Rentrop 0, Rentrop 1–2 and Rentrop 3, respectively; p < 0.001) and showed higher SSS (0.0 ± 0.0, 1.3 ± 1.6 and 2.1 ± 1.1 for Rentrop 0, Rentrop 1–2 and Rentrop 3, respectively; p = 0.001) and SRS (0.0 ± 0.0, 1.0 ± 1.4 and 1.7 ± 1.2; p = 0.003) at higher Rentrop grades, but their patterns were variable. Angina pectoris was related to either ischemia of the myocardium beyond CTO or a perfusion decrease in the donor myocardium. The perfusion decrease in donor myocardium positively correlated with the collateral grades.

  16. Dependence of intramyocardial pressure and coronary flow on ventricular loading and contractility: a model study.

    Science.gov (United States)

    Bovendeerd, Peter H M; Borsje, Petra; Arts, Theo; van De Vosse, Frans N

    2006-12-01

    The phasic coronary arterial inflow during the normal cardiac cycle has been explained with simple (waterfall, intramyocardial pump) models, emphasizing the role of ventricular pressure. To explain changes in isovolumic and low afterload beats, these models were extended with the effect of three-dimensional wall stress, nonlinear characteristics of the coronary bed, and extravascular fluid exchange. With the associated increase in the number of model parameters, a detailed parameter sensitivity analysis has become difficult. Therefore we investigated the primary relations between ventricular pressure and volume, wall stress, intramyocardial pressure and coronary blood flow, with a mathematical model with a limited number of parameters. The model replicates several experimental observations: the phasic character of coronary inflow is virtually independent of maximum ventricular pressure, the amplitude of the coronary flow signal varies about proportionally with cardiac contractility, and intramyocardial pressure in the ventricular wall may exceed ventricular pressure. A parameter sensitivity analysis shows that the normalized amplitude of coronary inflow is mainly determined by contractility, reflected in ventricular pressure and, at low ventricular volumes, radial wall stress. Normalized flow amplitude is less sensitive to myocardial coronary compliance and resistance, and to the relation between active fiber stress, time, and sarcomere shortening velocity.

  17. Pressure-flow characteristics and nutritional capacity of coronary veins in dogs

    International Nuclear Information System (INIS)

    Cohen, M.V.; Matsuki, T.; Downey, J.M.

    1988-01-01

    To examine the hemodynamic interdependence of coronary arteries and veins, great cardiac vein (GCV) and left anterior descending (LAD) coronary artery flows of dogs were measured. Although they were not different under base-line conditions, 42.9 +/- 4.1 and 34.9 +/- 5.2 ml/min, respectively, LAD occlusion caused only a 56% decrease in GCV flow, whereas peak GCV flow during reactive hyperemia consistently underestimated peak LAD flow by nearly 40%. The measured hemodynamic data were very closely predicted by a simple model that assumed the presence of a low-resistance venous collateral anastomotic pathway between the GCV and veins outside the LAD territory. The resistance of the venous collaterals averaged 9.9 +/- 3.0% of LAD resistance. Therefore, GCV flow does not solely represent LAD collateral flow when the LAD is occluded, nor is it a reliable indicator of changes in LAD perfusion patterns. Nutritional myocardial perfusion assessed with 133 Xe washout decreased from 0.86 +/- 0.16 to 0.13 +/- 0.02 ml.min-1.g-1 after LAD occlusion, whereas retroperfusion of the GCV with arterial blood enhanced washout by 85% to 0.23 +/- 0.03 ml.min-1.g-1 (P less than 0.005). Retroperfusion was inefficient, however, since only 10% of the isotope injected into the GCV gained access to the myocardium

  18. Thallium-201 myocardial perfusion imaging at rest and during exercise. Comparative sensitivity to electrocardiography in coronary artery disease

    International Nuclear Information System (INIS)

    Bailey, I.K.; Griffith, L.S.C.; Rouleau, J.; Strauss, H.W.; Pitt, B.

    1977-01-01

    The sensitivity of myocardial perfusion imaging (MPI) using thallium-201 injected both at rest and during peak exercise was compared to simultaneously recorded 12 lead electrocardiography (ECG) for the detection of transient ischemia in 20 normal subjects and 63 patients with coronary artery disease (CAD). No significant perfusion defects or ECG changes were seen on either the rest or exercise studies in any of the normal subjects. Fifty-six percent of patients with CAD developed new perfusion defects with exercise compared to 38 percent who developed ischemic ST-segment depression (P < 0.02). However, when chest pain and/or ST depression were considered indices of ischemia, the sensitivity of exercise testing and thallium-201 MPI was similar. The increased sensitivity of MPI compared to ST-segment depression on the ECG was due to patients with baseline ECG abnormalities and those who failed to achieve 85 percent of predicted maximum heart rate with exercise. Analysis of the exercise results according to the extent of coronary artery disease revealed a progressive increase in both positive ECGs and MPI with the number of vessels involved. In patients with single vessel disease the MPI was more sensitive than the ECG (P < 0.02). The combination of the rest and exercise ECG, MPI and chest pain during exercise failed to identify 11 percent of patients with CAD. Exercise thallium-201 MPI is a useful adjunct to conventional exercise testing particularly when evaluating patients with abnormal resting ECGs, those who develop ventricular conduction defects or arrhythmias during exercise, and those who fail to achieve their predicted heart rate because of fatigue or breathlessness

  19. Myocardial perfusion imaging by digital subtraction angiography

    International Nuclear Information System (INIS)

    Kadowaki, Hiroyuki; Ishikawa, Kinji; Ogai, Toshihiro; Katori, Ryo

    1986-01-01

    Several methods of digital subtraction angiography (DSA) were compared to determine which could better visualize regional myocardial perfusion using coronary angiography in seven patients with myocardial infarction, two with angina pectoris and five with normal coronary arteries. Satisfactory DSA was judged to be achieved if the shape of the heart on the mask film was identical to that on the live film and if both films were exactly superimposed. To obtain an identical mask film in the shape of each live film, both films were selected from the following three phases of the cardiac cycle; 1) at the R wave of the electrocardiogram, 2) 100 msec before the R wave, and 3) 200 msec before the R wave. The last two were superior for obtaining mask and live films which were similar in shape, because the cardiac motion in these phases was relatively small. Using these mask and live films, DSA was performed either with the continuous image mode (CI mode) or the time interval difference mode (TID mode). The overall perfusion of contrast medium through the artery to the vein was adequately visualized using the CI mode. Passage of contrast medium through the artery, capillary and vein was visualized at each phase using TID mode. Subtracted images were displayed and photographed, and the density of the contrast medium was adequate to display contour lines as in a relief map. Using this DSA, it was found that regional perfusion of the contrast medium was not always uniform in normal subjects, depending on the typography of the coronary artery. In all patients with anterior myocardial infarction, low perfusion was observed at the infarcted portion compared to the non-infarcted myocardium. In patients with inferior myocardial infarction, this low perfusion area was not observed because right coronary angiography was not subjected to DSA in this study. (J.P.N.)

  20. Adenosine stress and exercise 99Tcm-MIBI myocardial perfusion imaging in the diagnosis and risk stratification of patients with unstable angina

    International Nuclear Information System (INIS)

    Jia Peng; Guo Wanhua; Xu Shoulin; Feng Xuefeng

    2008-01-01

    Objective: The aim of this study was to evaluate the clinical value of adenosine stress or exercise 99 Tc m -methoxyisobutylisonitrile (MIBI) myocardial perfusion imaging in the diagnosis and risk stratification of patients with unstable angina. Methods: Eighty-seven hospitalized patients with unstable angina [54 men and 33 women, aged of (56.5±12.5) years] underwent adenosine stress or exercise myocardial perfusion imaging and coronary angiography. Patients were followed up. Results: Fifty-seven patients had abnormal myocardial perfusion imaging and significant coronary artery stenosis. Ten patients had abnormal myocardial perfusion imaging but normal coronary angiography. Eight patients had normal myocardial perfusion imaging but significant coronary artery stenosis. Twelve patients had normal myocardial perfusion imaging and normal coronary angiography. Patients with abnormal myocardial perfusion imaging had worse prognosis. There was relationship between cardiac events and the extent and severity of myocardial ischemia. Conclusion: Adenosine stress and exercise myocardial perfusion imaging is of important clinical value in the diagnosis and risk stratification of patients with unstable angina. (authors)

  1. Effects of a novel multimodal group intervention on myocardial perfusion in patients with coronary heart disease (CHD)

    International Nuclear Information System (INIS)

    Theissen, P.; Schicha, H.; Albus, C.; Koehle, K.; Griebenow, R.; Son, P.

    2002-01-01

    Full text: Recently, it could be shown that a multimodal intervention can promote health behavior in patients with CHD. Purpose of the actual study was to evaluate the effects on somatic endpoints, e.g. myocardial perfusion. We randomly assigned 77 patients (age 54 ± 6.9 y, male 87 %) with angiographically documented CHD to a multimodal group intervention plus standardized cardiological care (INT n=39) or standardized cardiological care only (CO n = 38). The intervention, for out-patients only, consisted of 77.5 hours of group-psychotherapy, relaxation and exercise training, and teaching lessons for one year. A Thallium myocardial perfusion scintigraphy (MyoSc) (after bicycle exercise test and at rest; 70 - 110 MBq Thallium-201, SPECT-technique, quantitative wash-out (w.-o.) analysis derived from polar maps) was performed at baseline, after 2 years, and 3 years, respectively: A w.-o. increase res. decrease by 5 % or more indicated an improved / a diminished myocardial perfusion within the affected coronary artery territory. Results were analyzed on an intention to treat basis. 70/77 patients (91 %) completed the study (drop-outs CO n=4, INT n=3). After 2 years (1st interval), there was no significant difference between groups. After 3 years (2nd interval) 36/39 patients (92.3 %) of INT showed a stable or improved myocardial perfusion, compared to 18/38 patients (47.4 %) of CO (p= 0.008). The recent data analysis demonstrates the extra benefit of a multimodal intervention, compared to standardized cardiological care alone, on myocardial perfusion in CHD patients. (author)

  2. Role of Coronary Myogenic Response in Pressure-Flow Autoregulation in Swine: A Meta-Analysis With Coronary Flow Modeling

    OpenAIRE

    Gregory M. Dick; Ravi Namani; Bhavesh Patel; Ghassan S. Kassab

    2018-01-01

    Myogenic responses (pressure-dependent contractions) of coronary arterioles play a role in autoregulation (relatively constant flow vs. pressure). Publications on myogenic reactivity in swine coronaries vary in caliber, analysis, and degree of responsiveness. Further, data on myogenic responses and autoregulation in swine have not been completely compiled, compared, and modeled. Thus, it has been difficult to understand these physiological phenomena. Our purpose was to: (a) analyze myogenic d...

  3. Wound healing in below-knee amputations in relation to skin perfusion pressure

    DEFF Research Database (Denmark)

    Holstein, P; Sager, P; Lassen, N A

    1979-01-01

    In 60 below-knee amputations the healing of the stumps was correlated with the local skin perfusion pressure (SPP) measured preoperatively as the external pressure required to stop isotope washout using 131I- or 125I--antipyrine mixed with histamine. Of the eight cases with an SPP below 20 mm...

  4. Value of myocardial perfusion SPECT in pediatric population

    International Nuclear Information System (INIS)

    Massardo, T.; Coll, C.; Prat, H.; Gonzalez, P.; Doggenweiller, P.; Castillo, M.E.; Solis, A.

    2002-01-01

    Isotopic myocardial perfusion studies are less frequently used in children than in adults and their indications are also different. Our goal was to analyze retrospectively the experience with stress perfusion myocardial SPECT in pediatric population. Method: Since 1998 to 2001, ten studies were performed to 5 girls and 3 boys. Their mean age was 7±3 years ranging from 1-11. Three of them presented abnormal coronary arteries pre and post surgical intervention with or without coil; three had Kawasaki disease with coronary aneurysms and the other two, congenital cardiopathies (Cantrell pentalogy and great vessel transposition,both with posterior left ventricular hypokinesia post surgery). Stress was obtained using dipyridamole infusion (0.56 mg/kg) in 6 cases and treadmill exercise using Bruce protocol in 4. All those tests were well tolerated. Sestamibi Tc99m was selected in 80% of the cases and Tl 201 in the rest. Only 2 small children required anesthesia during SPECT acquisition. Results: Stress EKG did not demonstrated ischemia in any case. Coronary angiography was performed only in 50% of the patients, it was concordant with SPECT features in all, two of those patients presented transient perfusion defects (one Kawasaki and one abnormal coronary artery with a fistulae).The repaired pentalogy presented ischemia and septal infarction; in that patient echocardiographic hipokinesia was concordant with fixed hypoperfusion. One case with abnormal coronary plus mitral regurgitation (without isotopic ischemia) was submitted to embolization posteriorly, obtaining motion improvement. Clinical outcome was concordant with the presence or absence of isotopic ischemia in the rest of the patients. Conclusion: SPECT myocardial perfusion was helpful in the therapeutic approach and in prediction of outcome in children

  5. Incremental Diagnostic Performance of Combined Parameters in the Detection of Severe Coronary Artery Disease Using Exercise Gated Myocardial Perfusion Imaging.

    Directory of Open Access Journals (Sweden)

    Chia-Ju Liu

    Full Text Available Myocardial perfusion imaging (MPI using gated single-photon emission tomography (gSPECT may underestimate the severity of coronary artery disease (CAD. This study aimed to evaluate the significance of combined parameters derived from gSPECT, as well as treadmill stress test parameters, in the detection of severe CAD.A total of 211 consecutive patients referred for exercise MPI between June 2011 and June 2013 (who received invasive coronary angiography within six months after MPI were retrospectively reviewed. Exercise MPI was performed with Bruce protocol and 201Tl injected at peak exercise. Gated SPECT was performed using a cadmium-zinc-telluride camera and processed by QPS/QGS software. Perfusion defect abnormalities such as sum stress score (SSS; sum difference score, algorithm-derived total perfusion deficits, transient ischemic dilatation ratios of end-diastolic volumes and end-systolic volumes, post-stress changes in ejection fraction, and lung/heart ratio (LHR were calculated. Treadmill parameters, including ST depression (STD at the 1st and 3rd minutes of recovery stage (1'STD and 3'STD, maximal STD corrected by heart rate increment (ST/HR, heart rate decline in 1st and 3rd minutes of recovery stage, recovery heart rate ratio (HR ratio, systolic and mean blood pressure ratios (SBP ratio and MAP ratio during recovery phase were recorded. Diagnostic performances of these parameters were analyzed with receiver operating characteristic (ROC analysis and logistic regression for detection of left main (≥ 50% or 3-vessel disease (all ≥ 70% luminal stenosis on invasive angiography.Among various MPI and treadmill parameters used for detection of severe CAD, SSS and ST/HR had the highest AUC (0.78, 0.73, p = NS and best cut-off values (SSS > 6, ST/HR > 17.39 10-2mV/bpm, respectively. By univariate logistic regression, all parameters except 1'HRR, 3'HRR, SBP and MAP ratios increased the odds ratio of severe CAD. Only increased L/H ratio, 3'STD

  6. Abnormalities of Microcirculation and Intracranial and Cerebral Perfusion Pressures in Severe Brain Injury

    Directory of Open Access Journals (Sweden)

    Yu. A. Churlyaev

    2008-01-01

    Full Text Available Objective: to evaluate the states of microcirculation, cerebral perfusion intracranial pressures in patients with isolated severe brain injury (SBI and to determine their possible relationships. Subjects and methods. 148 studies were performed in 16 victims with SBI. According to the outcome of brain traumatic disease, the patients were divided into two groups: 1 those who had a good outcome (n=8 and 2 those who had a fatal outcome (n=8. Microcirculation was examined by skin laser Doppler flowmetry using a LAKK-01 capillary blood flow laser analyzer (LAZMA Research-and-Production Association, Russian Federation. All the victims underwent surgical interventions to remove epi-, subdural, and intracerebral hematomas. A Codman subdural/intraparenchymatous intracranial pressure (ICD sensor (Johnson & Johnson, United Kingdom was intraoperatively inserted in the victims. Cerebral perfusion pressure (CPP was calculated using the generally accepted formula: CPP = MBP (mean blood pressure — ICD. ICD, CPP, and microcirculation were studied on postoperative days 1, 3, 5, and 7. Their values were recorded simultaneously. Ninety and 58 studies were conducted in the group of patients with good and fatal outcomes, respectively. Results. No correlation between the changes in MBP, ICD, and microcirculatory parameters suggested that the value of ICD was determined by the nature of brain damage and it was the leading and determining indicator in the diagnosis and treatment of secondary cerebral lesions. The amplitude of low-frequency fluctuations directly correlated with ICD, which indicated that they might be used to evaluate cerebral perfusion and impaired cerebral circulation indirectly in victims with severe brain injury. Conclusion. The laser Doppler flowmetric technique makes it possible not only to qualitatively, but also quantitatively determine changes in the tissue blood flow system in severe brain injury. With this technique, both the local and central

  7. Magnetic Resonance Imaging Measurement of Left Ventricular Blood Flow and Coronary Flow Reserve in Patients with Chronic Heart Failure due to Coronary Artery Disease

    International Nuclear Information System (INIS)

    Aras, A.; Anik, Y.; Demirci, A.; Balci, N.C.; Kozdag, G.; Ural, D.; Komsuogl u, B.

    2007-01-01

    Background: Coronary sinus flow reflects global cardiac perfusion and has been used for the assessment of myocardial flow reserve, which is reduced in chronic heart failure (CHF). Coronary flow reserve (CFR) can be measured by using phase-contrast (PC) velocity-encoded cine (VEC) magnetic resonance imaging (MRI). Purpose: To quantify and compare global left ventricular (LV) perfusion and CFR in patients with CHF and in a healthy control group by measuring coronary sinus flow with PC VEC MRI, and to correlate this with global LV perfusion, segmental first-pass perfusion, and viability in the same patients. Material and Methods: Cardiac MRI was performed in 20 patients with CHF of ischemic origin and in a control group of healthy subjects (n 11) at rest and after pharmacological stress induced by i.v. dipyridamole. The MRI protocol included cine MRI, VEC MRI, first-pass perfusion, and delayed contrast-enhanced MRI for viability. Global LV perfusion was quantified by measuring coronary sinus flow on VEC MRI at rest in all subjects. CFR was determined as the ratio of global LV perfusion before and after pharmacologic stress. Results: At rest, global LV perfusion was not significantly different in patients with CHF and the control group. After administration of dipyridamole, global LV perfusion and CFR were significantly lower in patients with CHF compared to the control group (P<0.001). An inverse correlation was observed between CFR and the number of infarcted and/or ischemic segments (P = 0.083, P 0.037). Conclusion: A combined cardiac MRI protocol including function and perfusion techniques together with VEC MRI can be used to evaluate global LV perfusion and CFR in patients with CHF. Global LV perfusion and CFR measurements may have potential in the monitoring of CHF. Impaired CFR may contribute to progressive decline in LV function in patients with CHF

  8. Magnetic Resonance Imaging Measurement of Left Ventricular Blood Flow and Coronary Flow Reserve in Patients with Chronic Heart Failure due to Coronary Artery Disease

    Energy Technology Data Exchange (ETDEWEB)

    Aras, A.; Anik, Y.; Demirci, A.; Balci, N.C.; Kozdag, G.; Ural, D.; Komsuoglu, B. (Radiology Dept. and Cardiology Dept., Kocaeli Univ. School of Medicine, Kocaeli (Turkey))

    2007-11-15

    Background: Coronary sinus flow reflects global cardiac perfusion and has been used for the assessment of myocardial flow reserve, which is reduced in chronic heart failure (CHF). Coronary flow reserve (CFR) can be measured by using phase-contrast (PC) velocity-encoded cine (VEC) magnetic resonance imaging (MRI). Purpose: To quantify and compare global left ventricular (LV) perfusion and CFR in patients with CHF and in a healthy control group by measuring coronary sinus flow with PC VEC MRI, and to correlate this with global LV perfusion, segmental first-pass perfusion, and viability in the same patients. Material and Methods: Cardiac MRI was performed in 20 patients with CHF of ischemic origin and in a control group of healthy subjects (n 11) at rest and after pharmacological stress induced by i.v. dipyridamole. The MRI protocol included cine MRI, VEC MRI, first-pass perfusion, and delayed contrast-enhanced MRI for viability. Global LV perfusion was quantified by measuring coronary sinus flow on VEC MRI at rest in all subjects. CFR was determined as the ratio of global LV perfusion before and after pharmacologic stress. Results: At rest, global LV perfusion was not significantly different in patients with CHF and the control group. After administration of dipyridamole, global LV perfusion and CFR were significantly lower in patients with CHF compared to the control group (P<0.001). An inverse correlation was observed between CFR and the number of infarcted and/or ischemic segments (P = 0.083, P = 0.037). Conclusion: A combined cardiac MRI protocol including function and perfusion techniques together with VEC MRI can be used to evaluate global LV perfusion and CFR in patients with CHF. Global LV perfusion and CFR measurements may have potential in the monitoring of CHF. Impaired CFR may contribute to progressive decline in LV function in patients with CHF

  9. Study of Nicorandil stress perfusion MRI in diagnosing ischemic heart disease

    International Nuclear Information System (INIS)

    Tateishi, Toshiki; Iwai, Mitsuhiro; Takeda, Soji; Hayashi, Ryuji

    2006-01-01

    The excellent spatial resolution of myocardial stress perfusion magnetic resonance imaging is effective for the diagnosis of ischemic heart disease. When dipyridamole or adenosine triphosphate is used as a pharmacological stress in cardiac MRI, non-magnetic instruments are required for infusion of these drugs in a MRI room. We attempted to use nicorandil as a pharmacological stressor. Nicorandil exhibited KATP channel opening and nitrate effects, and could be infused without any special instruments. Based on the coronary artery stenosis assessed by coronary angiography, according to the criteria of the American Heart Association (AHA), the sensitivity, specificity and diagnostic accuracy of nicorandil perfusion MRI for the detection of coronary artery stenosis was 85%, 57% and 74.3%, respectively. No major side effects were observed, except for mild hypotension (mean 10 mmHg) after infusion of the drug. It was concluded that myocardial perfusion MRI examination using nicorandil could be performed non-invasively and safely for the evaluation of coronary vessel disease in patients. (author)

  10. Spatial interaction between tissue pressure and skeletal muscle perfusion during contraction

    NARCIS (Netherlands)

    Donkelaar, van C.C.; Huyghe, J.M.R.J.; Vankan, W.J.; Drost, M.R.

    2001-01-01

    The vascular waterfall theory attributes decreased muscle perfusion during contraction to increased intramuscular pressure (P_IM ) and concomitant increase in venous resistance. Although P_IM is distributed during contractions, this theory does not account for heterogeneity.This study hypothesises

  11. Noninvasive quantification of myocardial perfusion heterogeneity by Markovian analysis in SPECT nuclear imaging

    International Nuclear Information System (INIS)

    Pons, G.

    2011-01-01

    Cardiovascular diseases are the leading cause of mortality worldwide, and third of these deaths are caused by coronary artery disease and rupture of vulnerable atherosclerotic plaques. The heterogeneous alteration of the coronary microcirculation is an early phenomenon associated with many cardiovascular risk factors that can strongly predict the subsequent development of coronary artery disease, and lead to the appearance of myocardial perfusion heterogeneity. Nuclear medicine allows the study of myocardial perfusion in clinical routine through scintigraphic scans performed after injection of a radioactive tracer of coronary blood flow. Analysis of scintigraphic perfusion images currently allows the detection of myocardial ischemia, but the ability of the technique to measure the perfusion heterogeneity in apparently normally perfused areas is unknown. The first part of this thesis focuses on a retrospective clinical study to determine the feasibility of myocardial perfusion heterogeneity quantification measured by Thallium-201 single photon emission computed tomography (SPECT) in diabetic patients compared with healthy subjects. The clinical study has demonstrated the ability of routine thallium-201 SPECT imaging to quantify greater myocardial perfusion heterogeneity in diabetic patients compared with normal subjects. The second part of this thesis tests the hypothesis that the myocardial perfusion heterogeneity could be quantified in small animal SPECT imaging by Thallium-201 and/or Technetium-99m-MIBI in an experimental study using two animal models of diabetes, and is correlated with histological changes. The lack of difference in myocardial perfusion heterogeneity between control and diabetic animals suggests that animal models are poorly suited, or that the technology currently available does not seem satisfactory to obtain similar results as the clinical study. (author)

  12. Thallium 201 Exercise Scintigraphy for Detection of Multivessel Coronary Artery Disease After Transmural Myocardial Infarction

    Science.gov (United States)

    Ahmadpour, Hedayatolah; Siegel, Michael E.; Colletti, Patrick; Haywood, L. Julian

    1984-01-01

    Fifty patients with prior transmural myocardial infarction were studied with cardiac catheterization, coronary angiography, and thallium 201 exercise perfusion scintigraphy. Obstructive coronary disease involved two or three vessels in 37 patients. The sensitivity of a positive electrocardiographic test during exercise for detecting multivessel coronary disease was only 40 percent (15/37), and the sensitivity of a reversible defect on 201Tl perfusion scintigraphy was 48 percent (18/37). The combination of exercise testing and 201Tl scintigraphy detected multivessel coronary disease in 75 percent (28/37) (P < .05). New perfusion defects occurred in 61 percent (13/21) of patients with inferior myocardial infarction and multivessel coronary disease whereas it occurred in only 35 percent (5/14) of patients with prior anterior infarction and multivessel coronary disease (P < .05). 201Tl exercise perfusion scintigraphy appears to be more sensitive for detecting significant multivessel coronary disease in the presence of previous inferior infarction compared with previous anterior infarction. Combined graded exercise testing and 201Tl perfusion scintigraphy can reliably detect the presence of significant multivessel coronary disease after transmural myocardial infarction. ImagesFigure 3 PMID:6512876

  13. Forward coronary flow normally seen in systole is the result of both forward and concealed back flow

    NARCIS (Netherlands)

    Spaan, J. A.; Breuls, N. P.; Laird, J. D.

    1981-01-01

    Normally systolic coronary blood flow is almost entirely forward. As perfusion pressure was lowered through the autoregulatory range in open-chest dogs, net systolic back flow appeared at approximately 70 mm Hg. Imposing a series resistance (Rs), which impedes both forward and back flow, abolished

  14. Reversible cold-induced abnormalities in myocardial perfusion and function in systemic sclerosis

    International Nuclear Information System (INIS)

    Alexander, E.L.; Firestein, G.S.; Weiss, J.L.; Heuser, R.R.; Leitl, G.; Wagner, H.N. Jr.; Brinker, J.A.; Ciuffo, A.A.; Becker, L.C.

    1986-01-01

    The effects of peripheral cold exposure on myocardial perfusion and function were studied in 13 patients with scleroderma without clinically evident myocardial disease. Ten patients had at least one transient, cold-induced, myocardial perfusion defect visualized by thallium-201 scintigraphy, and 12 had reversible, cold-induced, segmental left ventricular hypokinesis by two-dimensional echocardiography. The 10 patients with transient perfusion defects all had anatomically corresponding ventricular wall motion abnormalities. No one in either of two control groups (9 normal volunteers and 7 patients with chest pain and normal coronary arteriograms) had cold-induced abnormalities. This study is the first to show the simultaneous occurrence of cold-induced abnormalities in myocardial perfusion and function in patients with scleroderma. The results suggest that cold exposure in such patients may elicit transient reflex coronary vasoconstriction resulting in reversible myocardial ischemia and dysfunction. Chronic recurrent episodes of coronary spasm may lead to focal myocardial fibrosis

  15. Prevalence of silent myocardial ischaemia during exercise stress testing. Its relation to effort tolerance and myocardial perfusion abnormalities.

    Science.gov (United States)

    Fragasso, G; Sciammarella, M G; Rossetti, E E; Xuereb, R G; Xuereb, M; Bonetti, F; Carandente, O M; Margonato, A; Chierchia, S L

    1992-07-01

    The number of underperfused myocardial segments, the extent of coronary artery disease and the severity of impairment of coronary flow reserve were compared in 147 consecutive patients exhibiting painful or painless ischaemic ST segment depression on exercise testing. Of 147 patients, only 61 (41%) experienced angina (group 1) whilst 86 (59%) did not (group 2). In the two groups coronary disease was comparable for both extent and distribution, and neither the location of transient perfusion defects nor their relation to areas of old myocardial necrosis appeared to influence the presence or absence of chest pain. However, exercise duration, exercise time and rate-pressure product at the beginning of ischaemia were lower in group 1. Furthermore, a greater proportion of asymptomatic patients had only one ischaemic segment on 99mTc-MIBI perfusion scintigraphy. We conclude that: (1) in patients with effort angina and coronary disease, the incidence of electrocardiographic silent ischaemic events induced by exercise is similar to that observed in studies based on continuous ECG monitoring. (2) Exertional angina is more frequently associated with greater ischaemic areas and with more severe degrees of impairment of residual coronary flow reserve. (3) The presence of an old myocardial infarction does not appear to influence the incidence of ischaemic cardiac pain.

  16. Fatty acid metabolism in symptomatic patients with mitral valve prolapse but without coronary artery disease - comparison with 201Tl myocardial perfusion scintigraphy

    International Nuclear Information System (INIS)

    Voth, E.; Schicha, H.; Neumann, P.; Emrich, D.; Tebbe, U.

    1987-01-01

    Using 123 I-ω-heptadecanoic acid (HDA) and 201 Tl, respectively, myocardial fatty acid metabolism and perfusion were studied in 51 symptomatic patients with mitral valve prolapse (MVP) as diagnosed by ventriculography, and no evidence of coronary artery disease. Twelve subjects with normal coronary arteries and normal ventriculogram served as a control group for the evaluation of elimination kinetics of HDA. In the control group, the mean elimination half-life was 26.1±3.6 min, whereas the patients with MVP had a mean value of 25.0±6.4 min. In patients with MVP, a high incidence concerning abnormalities of accumulation and/or elimination of HDA occurred, namely accumulation defects in 31% and both prolonged and shortened elimination half-lives in 16% and 29%, respectively. Myocardial perfusion scintigraphy using 201 Tl showed abnormalities in 76%. Correlations were found between decreased uptake of HDA and prolonged elimination half-life as well as defects by 201 Tl, presumably due to ischemia based on small-vessel disease or abnormalities of cellular metabolism. (orig.) [de

  17. Diagnosis of coronary artery disease using myocardial perfusion SPECT in patients with diabetes mellitus: analysis of risk factors

    International Nuclear Information System (INIS)

    Seo, Ji Hyoung; Kang, Seong Min; Bae, Jin Ho; Jeong, Shin Young; Lee, Sang Woo; Yoo, Jeong Soo; Ahn, Byeong Cheol; Lee, Jae Tae

    2006-01-01

    Diabetes mellitus is a critical disease with higher rates of cardiovascular morbidity and mortality due to myocardial ischemia and infarction. There is growing interest in how to determine high-risk patients who are candidates for screening testing. This study was performed to evaluate the incidence of coronary artery disease (CAD) in diabetic patients detected by Tc-99m MIBI myocardial perfusion SPECT (MPS) and to assess risk factors of CAD and cardiac hard events. 203 diabetic patients (64 male, mean age 64.1 ± 9.0 years) who underwent MPS were included between Jan 2000 and July 2004. Cardiac death and nonfatal myocardial infarction (MI) were considered as hard events, and coronary angioplasty and bypass surgery >60 days after testing were considered as soft events. The mean follow-up period was 36 ± 18 months. Patients underwent exercise (n=6) or adenosine stress (n=197) myocardial perfusion SPECT. Perfusion defects on MPS were detected in 28.6% (58/203) of the patients. There was no cardiac death but 11 hard events were observed. The annual cardiac hard event rate was 1.1%. In univariate analysis of clinical factors, typical anginal pain, peripheral vascular disease, peripheral polyneuropathy, and resting ECG abnormality were significantly associated with the occurrence of hard events. Anginal pain, peripheral vascular disease, and resting ECG abnormality remained independent predictors of nonfatal MIs with multivariate analysis. Abnormal SPECT results were significantly associated with high prevalence of hard events but not independent predictors on uni- and multivariate analyses. patients who were male, had longer diabetes duration (especially over 20 years), peripheral vascular disease, peripheral polyneuropathy, or resting ECG abnormality had higher incidence of CAD. Among clinical factors in diabetic patients, typical angina, peripheral vascular disease, peripheral polyneuropathy, and resting ECG abnormality were strong predictors of hard events

  18. Diagnosis of coronary artery disease using myocardial perfusion SPECT in patients with diabetes mellitus: analysis of risk factors

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Ji Hyoung; Kang, Seong Min; Bae, Jin Ho; Jeong, Shin Young; Lee, Sang Woo; Yoo, Jeong Soo; Ahn, Byeong Cheol; Lee, Jae Tae [Kyungpook National University, Daegu, (Korea, Republic of)

    2006-06-15

    Diabetes mellitus is a critical disease with higher rates of cardiovascular morbidity and mortality due to myocardial ischemia and infarction. There is growing interest in how to determine high-risk patients who are candidates for screening testing. This study was performed to evaluate the incidence of coronary artery disease (CAD) in diabetic patients detected by Tc-99m MIBI myocardial perfusion SPECT (MPS) and to assess risk factors of CAD and cardiac hard events. 203 diabetic patients (64 male, mean age 64.1 {+-} 9.0 years) who underwent MPS were included between Jan 2000 and July 2004. Cardiac death and nonfatal myocardial infarction (MI) were considered as hard events, and coronary angioplasty and bypass surgery >60 days after testing were considered as soft events. The mean follow-up period was 36 {+-} 18 months. Patients underwent exercise (n=6) or adenosine stress (n=197) myocardial perfusion SPECT. Perfusion defects on MPS were detected in 28.6% (58/203) of the patients. There was no cardiac death but 11 hard events were observed. The annual cardiac hard event rate was 1.1%. In univariate analysis of clinical factors, typical anginal pain, peripheral vascular disease, peripheral polyneuropathy, and resting ECG abnormality were significantly associated with the occurrence of hard events. Anginal pain, peripheral vascular disease, and resting ECG abnormality remained independent predictors of nonfatal MIs with multivariate analysis. Abnormal SPECT results were significantly associated with high prevalence of hard events but not independent predictors on uni- and multivariate analyses. patients who were male, had longer diabetes duration (especially over 20 years), peripheral vascular disease, peripheral polyneuropathy, or resting ECG abnormality had higher incidence of CAD. Among clinical factors in diabetic patients, typical angina, peripheral vascular disease, peripheral polyneuropathy, and resting ECG abnormality were strong predictors of hard events.

  19. Myocardial perfusion assessment by dual-energy computed tomography in patients with intermediate to high likelihood of coronary artery disease

    International Nuclear Information System (INIS)

    De Zam, M.C.; Capunay, C.; Rodriguez Granillo, G.A.; Deviggiano, A.; Campisi, R.; Munain, M. López de; Vallejos, J.; Carrascosa, P.M.

    2015-01-01

    Objectives. We sought to explore the feasibility and diagnostic performance of dual-energy computed tomography (DECT) for the evaluation of myocardial perfusion in patients with intermediate to high likelihood of coronary artery disease (CAD), and to assess the impact of beam hardening artifacts (HAE). Methods. The present prospective study involved patients with known or suspected CAD referred for myocardial perfusion imaging by single-photon emission computed tomography (SPECT). Twenty patients were included in the study protocol, and scanned using DECT imaging (n = 20). The same pharmacological stress was used for DECT and SPECT scans. Results. A total of 680 left ventricular segments were evaluated by DECT and SPECT. The contrast to noise ratio was 8.8±2.9. The diagnostic performance of DECT was very good in identifying perfusion defects [area under ROC curve (AUC) of DECT 0.90 (0.86-0.94)] compared with SPECT, and remained unaffected when including only segments affected by beam hardening artifacts (BHA) [AUC= DECT 0.90 (0.84-0.96)]. Conclusions. In this pilot investigation, myocardial perfusion assessment by DECT imaging in patients with intermediate to high likelihood of CAD was feasible and remained unaffected by the presence of BHA. (authors) [es

  20. Non invasive evaluation of the coronary atherosclerosis illness in patients with silent ischemia: utility of the SPECT of myocardial perfusion. Electric, angiographic and image correlation; Valoracion no invasiva de la enfermedad ateroesclerosa coronaria en pacientes con isquemia silente: utilidad del SPECT de perfusion miocardica. Correlacion electrica, angiografica y de imagen

    Energy Technology Data Exchange (ETDEWEB)

    Puente B, A.; Roffe G, F.; Aceves C, J.; Gomez A, E. [Hospital Centro Medico Nacional 20 de Noviembre, ISSSTE, Mexico D.F. (Mexico)

    2005-07-01

    The objective of the work was to determine the utility of the SPECT (Single Photon Emission Computerized Tomography) of myocardial perfusion for the ischemia detection in asymptomatic patients with Coronary Atherosclerosis Illness. It was concluded that the SPECT of myocardial perfusion has a high sensitivity (97%) for the silent ischemia diagnosis.

  1. Evaluation of contrast wash-in and peak enhancement in adenosine first pass perfusion CMR in patients post bypass surgery

    Directory of Open Access Journals (Sweden)

    Schnackenburg Bernhard

    2010-05-01

    Full Text Available Abstract Background Adenosine first pass perfusion cardiovascular magnetic resonance (CMR yields excellent results for the detection of significant coronary artery disease (CAD. In patients with coronary artery bypass grafts (CABG the kinetics of a contrast bolus may by altered only due to different distances through the bypass grafts compared to native vessels, thereby possibly imitating a perfusion defect. The aim of the study was to evaluate semiquantitative perfusion parameters in order to assess possible differences in epicardial contrast kinetics in areas supplied by native coronaries and CABG, both without significant stenosis. Methods Twenty patients with invasive exclusion of significant CAD (control group and 38 patients with CABG without angiographically significant (≥50% stenosis in unbypassed coronaries or grafts were retrospectively included in the study. They underwent adenosine first pass (0.05 mmol/kg Gd-DTPA perfusion (3 short axis views/heart beat and late gadolinium enhancement (LGE imaging 1 day before invasive coronary angiography. Areas perfused by native coronaries and/or the different bypasses were identified in X-ray angiography using the 16 segment model. In each of these areas upslope and maximal signal intensity (SImax relative to the left ventricular parameters, time to 50% maximal signal intensity (TSI50%max and time to maximal signal intensity (TSImax were calculated. Results In areas perfused by coronary arteries with bypasses compared to native coronaries relative upslope and relative SImax did not show a significant difference. TSI50%max and TSImax in native coronaries and bypasses were 7.2s ± 1.9s vs. 7.5s ± 1.9s (p max resulted in a significant (p Conclusion Adenosine perfusion CMR in patients post CABG may be associated with a short delay in contrast arrival. However, once the contrast is in the myocardium there is similar wash-in kinetics and peak enhancement. Therefore, since the delay is only short

  2. Consideration of Normal Variation of Perfusion Measurements in the Quantitative Analysis of Myocardial Perfusion SPECT: Usefulness in Assessment of Viable Myocardium

    International Nuclear Information System (INIS)

    Paeng, Jin Chul; Lim, Il Han; Kim, Ki Bong; Lee, Dong Soo

    2008-01-01

    Although automatic quantification software of myocardial perfusion SPECT provides highly objective and reproducible quantitative measurements, there is still some limitation in the direct use of quantitative measurements. In this study we derived parameters using normal variation of perfusion measurements, and tried to test the usefulness of these parameters. In order to calculate normal variation of perfusion measurements on myocardial perfusion SPECT, 55 patients (M:F=28:27) of low-likelihood for coronary artery disease were enrolled and 201 Tl rest / 99m Tc-MIBI stress SPECT studies were performed. Using 20-segment model, mean (m) and standard deviation (SD) of perfusion were calculated in each segment. As a myocardial viability assessment group, another 48 patients with known coronary artery disease, who underwent coronary artery bypass graft surgery (CABG) were enrolled. 201 Tl rest / 99m Tc-MIBI stress / 201 Tl 24-hr delayed SPECT was performed before CABG and SPECT was followed up 3 months after CABG. From the preoperative 24-hr delayed SPECT, Q delay (perfusion measurement), Δ delay (Q delay .m) and Z delay ((Q delay .m)/SD) were defined and diagnostic performances of them for myocardial viability were evaluated using area under curve (AUC) on receiver operating characteristic (ROC) curve analysis. Segmental perfusion measurements showed considerable normal variations among segments. In men, the lowest segmental perfusion measurement was 51.8±6.5 and the highest segmental perfusion was 87.0±5.9, and they are 58.7±8.1 and 87.3±6.0, respectively in women. In the viability assessment, Q delay showed AUC of 0.633, while those for Δ delay and Z delay were 0.735 and 0.716, respectively. The AUCs of Δ delay and Z delay were significantly higher than that of Q delay (p=0.001 and 0.018, respectively). The diagnostic performance of Δ delay , which showed highest AUC, was 85% of sensitivity and 53% of specificity at the optimal cutoff of -24.7. On automatic

  3. Role of Coronary Myogenic Response in Pressure-Flow Autoregulation in Swine: A Meta-Analysis With Coronary Flow Modeling

    Science.gov (United States)

    Dick, Gregory M.; Namani, Ravi; Patel, Bhavesh; Kassab, Ghassan S.

    2018-01-01

    Myogenic responses (pressure-dependent contractions) of coronary arterioles play a role in autoregulation (relatively constant flow vs. pressure). Publications on myogenic reactivity in swine coronaries vary in caliber, analysis, and degree of responsiveness. Further, data on myogenic responses and autoregulation in swine have not been completely compiled, compared, and modeled. Thus, it has been difficult to understand these physiological phenomena. Our purpose was to: (a) analyze myogenic data with standard criteria; (b) assign results to diameter categories defined by morphometry; and (c) use our novel multiscale flow model to determine the extent to which ex vivo myogenic reactivity can explain autoregulation in vivo. When myogenic responses from the literature are an input for our model, the predicted coronary autoregulation approaches in vivo observations. More complete and appropriate data are now available to investigate the regulation of coronary blood flow in swine, a highly relevant model for human physiology and disease. PMID:29875686

  4. Role of Coronary Myogenic Response in Pressure-Flow Autoregulation in Swine: A Meta-Analysis With Coronary Flow Modeling

    Directory of Open Access Journals (Sweden)

    Gregory M. Dick

    2018-05-01

    Full Text Available Myogenic responses (pressure-dependent contractions of coronary arterioles play a role in autoregulation (relatively constant flow vs. pressure. Publications on myogenic reactivity in swine coronaries vary in caliber, analysis, and degree of responsiveness. Further, data on myogenic responses and autoregulation in swine have not been completely compiled, compared, and modeled. Thus, it has been difficult to understand these physiological phenomena. Our purpose was to: (a analyze myogenic data with standard criteria; (b assign results to diameter categories defined by morphometry; and (c use our novel multiscale flow model to determine the extent to which ex vivo myogenic reactivity can explain autoregulation in vivo. When myogenic responses from the literature are an input for our model, the predicted coronary autoregulation approaches in vivo observations. More complete and appropriate data are now available to investigate the regulation of coronary blood flow in swine, a highly relevant model for human physiology and disease.

  5. Systolic Compression of Epicardial Coronary and Intramural Arteries

    Science.gov (United States)

    Mohiddin, Saidi A.; Fananapazir, Lameh

    2002-01-01

    It has been suggested that systolic compression of epicardial coronary arteries is an important cause of myocardial ischemia and sudden death in children with hypertrophic cardiomyopathy. We examined the associations between sudden death, systolic coronary compression of intra- and epicardial arteries, myocardial perfusion abnormalities, and severity of hypertrophy in children with hypertrophic cardiomyopathy. We reviewed the angiograms from 57 children with hypertrophic cardiomyopathy for the presence of coronary and septal artery compression; coronary compression was present in 23 (40%). The left anterior descending artery was most often affected, and multiple sites were found in 4 children. Myocardial perfusion abnormalities were more frequently present in children with coronary compression than in those without (94% vs 47%, P = 0.002). Coronary compression was also associated with more severe septal hypertrophy and greater left ventricular outflow gradient. Septal branch compression was present in 65% of the children and was significantly associated with coronary compression, severity of septal hypertrophy, and outflow obstruction. Multivariate analysis showed that septal thickness and septal branch compression, but not coronary compression, were independent predictors of perfusion abnormalities. Coronary compression was not associated with symptom severity, ventricular tachycardia, or a worse prognosis. We conclude that compression of coronary arteries and their septal branches is common in children with hypertrophic cardiomyopathy and is related to the magnitude of left ventricular hypertrophy. Our findings suggest that coronary compression does not make an important contribution to myocardial ischemia in hypertrophic cardiomyopathy; however, left ventricular hypertrophy and compression of intramural arteries may contribute significantly. (Tex Heart Inst J 2002;29:290–8) PMID:12484613

  6. Quantification of myocardial perfusion using cardiac magnetic resonance imaging correlates significantly to rubidium-82 positron emission tomography in patients with severe coronary artery disease: A preliminary study

    International Nuclear Information System (INIS)

    Qayyum, Abbas A.; Hasbak, Philip; Larsson, Henrik B.W.; Christensen, Thomas E.; Ghotbi, Adam A.; Mathiasen, Anders B.

    2014-01-01

    Introduction: Aim was to compare absolute myocardial perfusion using cardiac magnetic resonance imaging (CMRI) based on Tikhonov's procedure of deconvolution and rubidium-82 positron emission tomography (Rb-82 PET). Materials and methods: Fourteen patients with coronary artery stenosis underwent rest and adenosine stress imaging by 1.5-Tesla MR Scanner and a mCT/PET 64-slice Scanner. CMRI were analyzed based on Tikhonov's procedure of deconvolution without specifying an explicit compartment model using our own software. PET images were analyzed using standard clinical software. CMRI and PET data was compared with Spearman's rho and Bland–Altman analysis. Results: CMRI results were strongly and significantly correlated with PET results for the absolute global myocardial perfusion differences (r = 0.805, p = 0.001) and for global myocardial perfusion reserve (MPR) (r = 0.886, p < 0.001). At vessel territorial level, CMRI results were also significantly correlated with absolute PET myocardial perfusion differences (r = 0.737, p < 0.001) and MPR (r = 0.818, p < 0.001). Each vessel territory had similar strong correlation for absolute myocardial perfusion differences (right coronary artery (RCA): r = 0.787, p = 0.001; left anterior descending artery (LAD): r = 0.796, p = 0.001; left circumflex artery (LCX): r = 0.880, p < 0.001) and for MPR (RCA: r = 0.895, p < 0.001; LAD: r = 0.886, p < 0.001; LCX: r = 0.886, p < 0.001). Conclusion: On a global and vessel territorial basis, CMRI-measured absolute myocardial perfusion differences and MPR were strongly and significantly correlated with the Rb-82 PET findings

  7. Quantification of myocardial perfusion using cardiac magnetic resonance imaging correlates significantly to rubidium-82 positron emission tomography in patients with severe coronary artery disease: A preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Qayyum, Abbas A., E-mail: abbas.ali.qayyum@regionh.dk [Department of Cardiology and Cardiac Catheterization Laboratory 2014, The Heart Centre, Rigshospitalet, University Hospital of Copenhagen and Faculty of Health Sciences, Copenhagen University, Blegdamsvej 9, 2100 Copenhagen (Denmark); Hasbak, Philip, E-mail: philip.hasbak@regionh.dk [Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, University Hospital of Copenhagen and Faculty of Health Sciences, Copenhagen University, Blegdamsvej 9, 2100 Copenhagen (Denmark); Larsson, Henrik B.W., E-mail: henrik.larsson@regionh.dk [Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, University Hospital of Copenhagen and Faculty of Health Sciences, Copenhagen University, Blegdamsvej 9, 2100 Copenhagen (Denmark); Functional Imaging Unit, Diagnostic Department, Glostrup Hospital, University Hospital of Copenhagen and Faculty of Health Sciences, Copenhagen University, Ndr. Ringvej 57, 2600 Copenhagen (Denmark); Christensen, Thomas E., E-mail: thomas.emil.christensen@regionh.dk [Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, University Hospital of Copenhagen and Faculty of Health Sciences, Copenhagen University, Blegdamsvej 9, 2100 Copenhagen (Denmark); Ghotbi, Adam A., E-mail: adam.ali.ghotbi@regionh.dk [Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, University Hospital of Copenhagen and Faculty of Health Sciences, Copenhagen University, Blegdamsvej 9, 2100 Copenhagen (Denmark); Mathiasen, Anders B., E-mail: anders.b.mathiasen@gmail.com [Department of Cardiology and Cardiac Catheterization Laboratory 2014, The Heart Centre, Rigshospitalet, University Hospital of Copenhagen and Faculty of Health Sciences, Copenhagen University, Blegdamsvej 9, 2100 Copenhagen (Denmark); and others

    2014-07-15

    Introduction: Aim was to compare absolute myocardial perfusion using cardiac magnetic resonance imaging (CMRI) based on Tikhonov's procedure of deconvolution and rubidium-82 positron emission tomography (Rb-82 PET). Materials and methods: Fourteen patients with coronary artery stenosis underwent rest and adenosine stress imaging by 1.5-Tesla MR Scanner and a mCT/PET 64-slice Scanner. CMRI were analyzed based on Tikhonov's procedure of deconvolution without specifying an explicit compartment model using our own software. PET images were analyzed using standard clinical software. CMRI and PET data was compared with Spearman's rho and Bland–Altman analysis. Results: CMRI results were strongly and significantly correlated with PET results for the absolute global myocardial perfusion differences (r = 0.805, p = 0.001) and for global myocardial perfusion reserve (MPR) (r = 0.886, p < 0.001). At vessel territorial level, CMRI results were also significantly correlated with absolute PET myocardial perfusion differences (r = 0.737, p < 0.001) and MPR (r = 0.818, p < 0.001). Each vessel territory had similar strong correlation for absolute myocardial perfusion differences (right coronary artery (RCA): r = 0.787, p = 0.001; left anterior descending artery (LAD): r = 0.796, p = 0.001; left circumflex artery (LCX): r = 0.880, p < 0.001) and for MPR (RCA: r = 0.895, p < 0.001; LAD: r = 0.886, p < 0.001; LCX: r = 0.886, p < 0.001). Conclusion: On a global and vessel territorial basis, CMRI-measured absolute myocardial perfusion differences and MPR were strongly and significantly correlated with the Rb-82 PET findings.

  8. Effect of Citrus paradisi extract and juice on arterial pressure both in vitro and in vivo.

    Science.gov (United States)

    Díaz-Juárez, J A; Tenorio-López, F A; Zarco-Olvera, G; Valle-Mondragón, L Del; Torres-Narváez, J C; Pastelín-Hernández, G

    2009-07-01

    Citrus paradisi (grapefruit) consumption is considered as beneficial and it is popularly used for the treatment of a vast array of diseases, including hypertension. In the present study, the coronary vasodilator and hypotensive effects of Citrus paradisi peel extract were assessed in the Langendorff isolated and perfused heart model and in the heart and lung dog preparation. In both models, Citrus paradisi peel extract decreased coronary vascular resistance and mean arterial pressure when compared with control values (60 +/- 15 x 10(7) dyn s cm(-5) vs 100 +/- 10 x 10(7) dyn s cm(-5) and 90 mmHg vs 130 +/- 15 mmHg, respectively). These decreases in coronary vascular resistance and mean arterial pressure were blocked when isolated and perfused hearts and mongrel dogs were pre-treated with L-NAME. In humans, Citrus paradisi juice decreased diastolic arterial pressure and systolic arterial pressure both in normotensive and hypertensive subjects. Citrus paradisi juice produced a greater decrease in mean arterial pressure when compared with Citrus sinensis juice, cow milk and a vitamin C-supplemented beverage. However, more detailed studies are required to isolate, purify and evaluate the chemical compounds responsible for this pharmacological effect and to clarify its possible role for treating hypertension. Copyright 2009 John Wiley & Sons, Ltd.

  9. Analysis of the diagnostic value of the Gated-SPECT study of myocardial perfusion in the diagnosis of coronary disease in users seen at the Hospital Rafael Angel Calderon Guardia

    International Nuclear Information System (INIS)

    Calvo Montero, Karla; Coto Rodriguez, Maria Fernanda

    2011-01-01

    An analysis of the diagnostic value of the Gated-SPECT study of myocardial perfusion with Sestamibi marked with 99m Tc for the diagnosis of Coronary Disease was performed at the Hospital Rafael Angel Calderon Guardia. 13 patients with nuclear study and coronary angiography performed, were selected for the investigation. An estimate of the sensitivity, specificity and predictive values of the myocardial perfusion study was performed for the detection of the disease. Then, these values were related to socio-demographic and clinical characteristics of the patients submitted to the diagnosis. The need to use appropriate criteria to request this type of study was evidenced when determining that most of the patients presented risk factors compared to 26% of patients who did not present any factor [es

  10. Myocardial perfusion scintigraphy with technetium99m-MIBI in the diagnosis of coronary artery disease in women

    International Nuclear Information System (INIS)

    Peix, A.T.; Chacon, D.; Ponce, F.; Torres, M.; Llerena, L.; Lopez, A.; Cabrera, O.; Maltas, A.M.; Carrillo, R.

    2002-01-01

    Aim: To assess the value of myocardial perfusion scintigraphy for coronary artery disease (CAD) in women, we compared the results of a technetium99m-methoxy-isobutyl-isonitrile ( 99m Tc-MIBI) scintigraphy with those of a coronary angiography in a group of women referred for evaluation of chest pain. Material and Methods: Twenty women, 15 of them postmenopausal, were included. A 99m Tc-MIBI myocardial scintigraphy with one-day protocol (rest-stress) was performed. When needed, a combined stress (ergometric plus dipyridamole) was used. Both qualitative and quantitative regional uptake analysis was done. In patients with normal coronary arteries and positive myocardial scintigraphies, measurements were made of serum cholesterol and triglycerides (CHOD-PAD enzymatic colorimetric test), and lipoprotein(a) -Lp(a)- (BioSCREEN Lp(a) method). Results: Change in regional uptake (stress/rest) was as follows: during stress 99m Tc-MIBI, 116 segments had normal uptake (from 93±9% to 94±7%), 52 had moderately reduced uptake (from 67±9% to 75±17%), and 12 had severely reduced uptake (from 33±9% to 64±28%). Qualitative and quantitative analysis coincided in 18 cases. The two non-coincident cases were patients in whom qualitative analysis and coronary angiography were normal, but on quantitative analysis it appeared a reversible defect in one case and a 'reverse redistribution' pattern in the other. Breast attenuation defects were detected in four cases. Myocardial scintigraphy and coronary angiography coincided in 70% cases (figure). The remainder 30% was constituted by patients with positive scintigraphy and normal coronary arteries; among these cases, the 71% were postmenopausal and had systolic hypertension, chest pain at rest, positive ergometric test and hypercholesterolemia (table). Conclusion: We concluded that 99m Tc-MIBI myocardial scintigraphy can help in the CAD diagnosis in postmenopausal women

  11. Coronary diastolic pressure-flow relation and zero flow pressure explained on the basis of intramyocardial compliance

    NARCIS (Netherlands)

    Spaan, J. A.

    1985-01-01

    In the controversy about the mechanisms determining the high zero flow pressures and the further interpretation of coronary diastolic pressure flow relations, this paper takes a stand in favor of intramyocardial compliance as the primary cause of the high zero flow pressures. An attempt has been

  12. Diagnosis of coronary artery disease

    International Nuclear Information System (INIS)

    Pfisterer, M.; Gordon, D.; Battler, A.; Ashburn, W.; Froelicher, V.; Kantonsspital Basel

    1979-01-01

    In order to compare the three non-invasive exercise tests Ecg, Thallium myocardial perfusion imaging and radionuclide angiography in the diagnosis of coronary artery disease, the results of these tests in a consecutive series of 30 patients and 14 controls were analyzed. In all 88 symptom-limited exercise tests a significantly higher double product (heart rate x systolic blood pressure, mm Hg/min) was reached on a treadmill test (for Ecg and Thallium scintigraphy) as compared to the supine bicycle ergometer exercise (for radionuclide angiography): 243.1 +- 61.1 vs. 215.2 +- 46.5 x 10 2 (p [de

  13. Myocardial perfusion magnetic resonance imaging using sliding-window conjugate-gradient HYPR methods in canine with stenotic coronary arteries.

    Science.gov (United States)

    Ge, Lan; Kino, Aya; Lee, Daniel; Dharmakumar, Rohan; Carr, James C; Li, Debiao

    2010-01-01

    First-pass perfusion magnetic resonance imaging (MRI) is a promising technique for detecting ischemic heart disease. However, the diagnostic value of the method is limited by the low spatial coverage, resolution, signal-to-noise ratio (SNR), and cardiac motion-related image artifacts. A combination of sliding window and conjugate-gradient HighlY constrained back-PRojection reconstruction (SW-CG-HYPR) method has been proposed in healthy volunteer studies to reduce the acquisition window for each slice while maintaining the temporal resolution of 1 frame per heartbeat in myocardial perfusion MRI. This method allows for improved spatial coverage, resolution, and SNR. In this study, we use a controlled animal model to test whether the myocardial territory supplied by a stenotic coronary artery can be detected accurately by SW-CG-HYPR perfusion method under pharmacological stress. Results from 6 mongrel dogs (15-25 kg) studies demonstrate the feasibility of SW-CG-HYPR to detect regional perfusion defects. Using this method, the acquisition time per cardiac cycle was reduced by a factor of 4, and the spatial coverage was increased from 2 to 3 slices to 6 slices as compared with the conventional techniques including both turbo-Fast Low Angle Short (FLASH) and echoplanar imaging (EPI). The SNR of the healthy myocardium at peak enhancement with SW-CG-HYPR (12.68 ± 2.46) is significantly higher (P < 0.01) than the turbo-FLASH (8.65 ± 1.93) and EPI (5.48 ± 1.24). The spatial resolution of SW-CG-HYPR images is 1.2 × 1.2 × 8.0 mm, which is better than the turbo-FLASH (1.8 × 1.8 × 8.0 mm) and EPI (2.0 × 1.8 × 8.0 mm). Sliding-window CG-HYPR is a promising technique for myocardial perfusion MRI. This technique provides higher image quality with respect to significantly improved SNR and spatial resolution of the myocardial perfusion images, which might improve myocardial perfusion imaging in a clinical setting.

  14. Diagnostic Value of Myocardial Perfusion SPECT with Dipyridamole in a Female Population

    International Nuclear Information System (INIS)

    Perez-Iruela, Juan; Pastor, Purificacion; Lumbreras, Luis; Martin, Ana M.; Ruiz, Francisco J.; Posadas, A.; Puentes, Carmen

    2009-01-01

    Background: Exercise stress scintigraphy is a safe procedure widely used for the diagnosis of ischemic heart disease. Pharmacologic stress testing is an important alternative. The delayed presentation of ischemic heart disease in women, together with a lower diagnostic accuracy of exercise stress testing in this population, has generated interest in the potential benefits provided by myocardial perfusion imaging tests. Objective: To determine the diagnostic value of myocardial perfusion images with 99m Tc-tetrofosmin in a one day protocol after a pharmacologic stress with dipyridamole in a female population, and the relation with the coronary territories using coronary angiography as a reference technique. Material and Methods: In total, 149 clinical charts of women with suspected ischemic heart disease undergoing myocardial perfusion imaging tests and coronary angiography were retrospectively analyzed. Results: Sensitivity and specificity were 94% (93.47%-94.53%) and 82% (80.94%-83.06%), respectively. Values of sensitivity and specificity according to coronary territories were 71.62% (70.88%-72.36%) and 76% (75.27%-76.73%) for the left anterior descending (LAD) artery, 69.09% (68.11%-70.07%) and 76.84% (76.26%-77.42%) for the left circumflex (LCx) coronary artery, and 87.23% (86.11%-88.36%) and 74.51% (73.97%-75.05%) for the right coronary artery (RCA), respectively. Conclusion: Myocardial perfusion scintigraphy with 99m Tc-tetrofosmin and dipyridamole using a one day stress-rest protocol has high sensitivity and specificity for the diagnosis of ischemic heart disease in women. (authors) [es

  15. Comparison of exercise electrocardiography and stress perfusion CMR for the detection of coronary artery disease in women

    Directory of Open Access Journals (Sweden)

    Greulich Simon

    2012-06-01

    Full Text Available Abstract Background Exercise electrocardiography (ECG is frequently used in the work-up of patients with suspected coronary artery disease (CAD, however the accuracy is reduced in women. Cardiovascular magnetic resonance (CMR stress testing can accurately diagnose CAD in women. To date, a direct comparison of CMR to ECG has not been performed. Methods and results We prospectively enrolled 88 consecutive women with chest pain or other symptoms suggestive of CAD. Patients underwent a comprehensive clinical evaluation, exercise ECG, a CMR stress test including perfusion and infarct imaging, and x-ray coronary angiography (CA within 24 hours. CAD was defined as stenosis ≥70% on quantitative analysis of CA. Exercise ECG, CMR and CA was completed in 68 females (age 66.4 ± 8.8 years, number of CAD risk factors 3.5 ± 1.4. The prevalence of CAD on CA was 29%. The Duke treadmill score (DTS in the entire group was −3.0 ± 5.4 and was similar in those with and without CAD (−4.5 ± 5.8 and −2.4 ± 5.1; P = 0.12. Sensitivity, specificity and accuracy for CAD diagnosis was higher for CMR compared with exercise ECG (sensitivities 85% and 50%, P = 0.02, specificities 94% and 73%, P = 0.01, and accuracies 91% and 66%, P = 0.0007, respectively. Even after applying the DTS the accuracy of CMR was higher compared to exercise ECG (area under ROC curve 0.94 ± 0.03 vs 0.56 ± 0.07; P = 0.0001. Conclusions In women with intermediate-to-high risk for CAD who are able to exercise and have interpretable resting ECG, CMR stress perfusion imaging has higher accuracy for the detection of relevant obstruction of the epicardial coronaries when directly compared to exercise ECG.

  16. Evaluation of coronary hemodynamics and exercise 201Tl-myocardial scintigraphy in patients with vasospastic angina

    International Nuclear Information System (INIS)

    Matsumura, Kentaro; Nakase, Emiko; Haiyama, Tohru; Hasegawa, Akira; Saito, Takayuki

    1992-01-01

    To clarify the coronary hemodynamics and myocardial perfusion in patients with vasospastic angina, we performed exercise 201 Tl-myocardial scintigraphy (planar and SPECT) in 72 patients and left coronary digital subtraction angiography (DSA) in 37 patients without significant organic coronary artery stenosis. Coronary artery spasm was documented by coronary angiography in all patients. Fifty-four patients (75%) developed exercise-induced 201 Tl-myocardial perfusion defect on SPECT. 201 Tl pulmonary uptake (L/H) was significantly increased in patients with vasospastic angina. Especially, L/H was higher in patients with multiple small perfusion defect on 201 Tl-SPECT, so that exercise-induced left ventricular dysfunction existed in patients with vasospastic angina and especially in cases of multiple small perfusion defect on 201 Tl-SPECT. The left coronary circulation time (CCT) was prolonged in patients with vasospastic angina. The mechanism of prolonged CCT is still unknown, but we suspected that prolonged CCT was induced by increased peripheral coronary vascular resistance in patients with vasospastic angina. It was concluded that the peripheral coronary circulation was disturbed in patients with vasospastic angina, but its abnormal coronary circulation had no relation to location of spasm-induced vessels. We concluded that impaired coronary microcirculation was taken a part of pathophysiology in vasospastic angina. (author)

  17. Large-Animal Biventricular Working Heart Perfusion System with Low Priming Volume-Comparison between in vivo and ex vivo Cardiac Function.

    Science.gov (United States)

    Abicht, Jan-Michael; Mayr, Tanja Axinja Jelena; Jauch, Judith; Guethoff, Sonja; Buchholz, Stefan; Reichart, Bruno; Bauer, Andreas

    2018-01-01

    Existing large-animal, ex vivo, cardiac perfusion models are restricted in their ability to establish an ischemia/reperfusion condition as seen in cardiac surgery or transplantation. Other working heart systems only challenge one ventricle or require a substantially larger priming volume. We describe a novel biventricular cardiac perfusion system with reduced priming volume. Juvenile pig hearts were cardiopleged, explanted, and reperfused ex vivo after 150 minutes of cold ischemia. Autologous whole blood was used as perfusate (minimal priming volume 350 mL). After 15 minutes of Langendorff perfusion (LM), the system was switched into a biventricular working mode (WM) and studied for 3 hours. During reperfusion, complete unloading of both ventricles and constant-pressure coronary perfusion was achieved. During working mode perfusion, the preload and afterload pressure of both ventricles was controlled within the targeted physiologic range. Functional parameters such as left ventricular work index were reduced in ex vivo working mode (in vivo: 787 ± 186 vs. 1 h WM 498 ± 66 mm Hg·mL/g·min; p  hours while functional and blood parameters are easily accessible. Moreover, because of the minimal priming volume, the novel ex vivo cardiac perfusion circuit allows for autologous perfusion, using the limited amount of blood available from the organ donating animal. Georg Thieme Verlag KG Stuttgart · New York.

  18. The role of coronary microvascular dysfunction in the genesis of cardiovascular diseases

    International Nuclear Information System (INIS)

    Parodi, O.; Sambuceti, G.

    1996-01-01

    Using PET, myocardial perfusion abnormalities secondary to microvascular disorders have beeen investigated in arterial hypertension (AH), dilated and hypertrophic cardiomyopathy (CM), as well as in ischemic heart disease (CAD). In AH, regional perfusion at rest is within the normal range, while the coronary reserve and flow response to increase in metabolic demand are blunted. Both dilated and hypertrophic CM demonstrate abnormal vasodilaing capability, wich as bee schown to be presented in the subclinical form of dilated DM; the reduction of coronary reserve is not related to the presence and extent of the hemodynamic impairment in dilated CM, and involved also nonhypertropied myocardium in asymmetric hypertropic CM. These finding indicate a primary involvement of coronary microcirculation in non advanced forms of dilated and hypertrophic CM. Finally, in patients with CAD, myocardia teritories supplied by angiographically normal coronary arteries schow abnormal coronary reserve and flow during pacing, tachycardia, indicating that, even in absence of epicardial coronary artery obstruction, microcirculation is impaired in subject with coronary atherosclerosis. this abnormally can smooth perfusion differences, between control andd jeopardized regions. Although the agreement with the angiographic documantation of coronary artery disease has been frequently considered to characterize the diagnostic reliability of these techiques, the evaluation of myocardial perfusion provides an independent tool for the functional assessment of patient with heart disease. The possibility of obtain measurement of regional myocardial blood flow, provided by positron emission thermography, helps to identify the mechanisms affecting flow regulation in the myocardium. This tool thus provides a new rationale for the application of perfusion imaging, to obtain a more precise characterization of these patients, beyond the agreement with the morphological angiographic picture

  19. Altered myocardial perfusion during dobutamine stress testing in silent versus symptomatic myocardial ischaemia assessed by quantitative MIBI SPET imaging

    International Nuclear Information System (INIS)

    Elhendy, A.; Geleijnse, M.L.; Roelandt, J.R.T.C.; Cornel, J.H.; Domburg, R.T van; Reijs, A.E.M.; Nierop, P.R.; Fioretti, P.M.

    1996-01-01

    The aim of the study was to compare the extent and severity of reversible underperfusion in silent versus painful myocardial ischaemia during the dobutamine stress test. A consecutive series of 85 patients with significant coronary artery disease and reversible perfusion defects on technetium-99m methoxyisobutylisonitrile single-photon emission tomography performed at rest and during high-dose dobutamine stress (up to 40 μg kg -1 min -1 ) were studied. The left ventricle was divided into six segments. An ischaemic perfusion score was derived quantitatively by subtracting the rest from the stress defect score. Patients with multivessel disease had a higher ischaemic score (610±762 vs 310±411, P<0.05) and a higher number of reversible perfusion defects (2.1±1.2 vs 1.1±0.8, P<0.01) than patients with single-vessel disease. Typical angina occurred in 37 patients (44%) during the test. There was no significant difference between patients with and patients without angina with respecft to age, gender, peak rate-pressure product, prevalence of previous myocardial infarction, diabetes mellitus, multivessel disease or number of stenotic coronary arteries. Stress, rest and ischaemic scores as well as the number and distribution of reversible defects were not different in patients with and patients without angina. Patients with angina more frequently had a history of typical angina before the test (43% vs 17%, P<0.01) and ST-segment depression during the test (54% vs 25%, P<0.01). It is concluded that in patients with coronary artery disease and ischaemia detected by dobutamine scintigraphy, the extent and severity of coronary artery disease and myocardial perfusion abnormalities are similar with or without angina during stess testing. (orig.)

  20. Single-photon emission computed tomography for the assessment of ventricular perfusion and function

    International Nuclear Information System (INIS)

    Gonzalez, Patricio; Dussaillant, Gaston; Gutierrez, Daniela; Berrocal, Isabel; Alay, Rita; Otarola, Sonia

    2013-01-01

    Background: Single-photon emission computed tomography (SPECT) can be used as a non-invasive tool for the assessment of coronary perfusion. Aim: To assess ventricular perfusion and function by SPECT in patients with single vessel coronary artery disease. Material and Methods: Among patients with indications for a coronary artery angiography, those with significant lesions in one vessel, were selected for the study. Within 24 hours, cardiac SPECT examinations on basal conditions and after high doses of dipyridamole, were performed. SPECT data from 38 patients with a low probability of coronary artery disease was used for comparisons. Results:Ten patients aged 61 ± 8 years (seven men) were studied. Visual analysis of SPECT revealed signs suggestive of ischemia in eight patients. The remaining two patients did not have perfusion disturbances. SPECT detected eight of ten abnormal vessels reported in the coronary artery angiography. There were two false negative results Summed stress, summed rest and summed difference scores were 9.78 ± 6.51, 3.22 ± 5.07 and 6.33 ± 4.97, respectively. The ejection fractions under stress and at rest were 53 ± 11.7% and 61 ± 15.7% respectively (p ≤ 0.01). The figures for the control group were 69.1 ± 13.5% and 75.2 ± 12.04% respectively (significantly different from patients). Two patients had a summed motion score above 14.9. Likewise, two patients had a summed thickening score above 10.9. Conclusions: SPECT detected 80% of coronary lesions found during coronary artery angiography. Visual analysis of perfusion is highly reliable for diagnosis. Quantitative parameters must be considered only as reference parameters

  1. Observed Influence of Nitroglycerine on Myocardial Perfusion Scintigraphy in Patients with Multiple Vessel Coronary Artery Disease and Well-Developed Collaterals

    International Nuclear Information System (INIS)

    Rasulova, Nigora; Nazirova, Lyudmila; Akhmedov, Khasan; Akhmedova, Dilyafruz; Djalalov, Farrukh; Seydaliev, Amet; Iskandarov, Farkhod; Kok, T. Y.

    2012-01-01

    The objective of this scientific work was to evaluate the extent and severity of perfusion abnormalities on myocardial perfusion scintigraphy (MPS) at rest and with sublingual nitroglycerine, in relation to the presence and anatomical location of collaterals demonstrated by selective coronary angiography (SCA). Twenty-eight patients with unstable angina underwent selective coronary angiography. Eighteen of them were diagnosed with myocardial infarction (MI) 2–15 days prior to examination. Presence or absence of collaterals was noted, with anatomical depiction of donor and recipient arteries as well as evaluation of degree of collateral flow. As an inclusion criterion, collateral flow had to be grade 2 (partial epicardial filling of the occluded artery) or 3 (complete epicardial filling of the occluded artery) in accordance with the Rentrop collateral flow classification. Flow was noted as follows: Complete antegrade (CA), complete retrograde (CR), partial antegrade (PA), and partial retrograde (PR). Myocardial perfusion scintigraphy using Tc-99m Sestamibi at rest and after sublingual administration of nitroglycerine was performed according to a 2-day protocol. Perfusion abnormalities, which were quantified using the 20-segments model and visual 5-point system (0, normal perfusion; 4, absent perfusion), were analyzed according to donor's and recipient's territories, as well as territories with limited or without collateral flow (PA/PR, grade 0–1 flow). A total of 84 arteries were analyzed, with stenosis in 79 of them. Arteries were divided into three groups: Donors (group I), recipients (group II), and arteries with limited or without collaterals (group III). In group I, there were 28 donor arteries, with mean severity of stenosis 71.3 ± 0.65%. In group II, there were 36 recipient arteries and mean severity of stenosis was 94.8 ± 0.26%. In group III, there were 20 arteries, and all of them had either no or poorly developed collaterals (mean severity

  2. Coronary microvasculopathy in heart transplantation: Consequences and therapeutic implications.

    Science.gov (United States)

    Vecchiati, Alessandra; Tellatin, Sara; Angelini, Annalisa; Iliceto, Sabino; Tona, Francesco

    2014-06-24

    Despite the progress made in the prevention and treatment of rejection of the transplanted heart, cardiac allograft vasculopathy (CAV) remains the main cause of death in late survival transplanted patients. CAV consists of a progressive diffuse intimal hyperplasia and the proliferation of vascular smooth muscle cells, ending in wall thickening of epicardial vessels, intramyocardial arteries (50-20 μm), arterioles (20-10 μm), and capillaries (system. The non-immunological factors are older donor age, ischemia-reperfusion time, hyperlipidemia and CMV infections. Diagnostic techniques that are able to assess microvascular function are lacking. Intravascular ultrasound and fractional flow reserve, when performed during coronary angiography, are able to detect epicardial coronary artery disease but are not sensitive enough to assess microvascular changes. Some authors have proposed an index of microcirculatory resistance during maximal hyperemia, which is calculated by dividing pressure by flow (distal pressure multiplied by the hyperemic mean transit time). Non-invasive methods to assess coronary physiology are stress echocardiography, coronary flow reserve by transthoracic Doppler echocardiography, single photon emission computed tomography, and perfusion cardiac magnetic resonance. In this review, we intend to analyze the mechanisms, consequences and therapeutic implications of microvascular dysfunction, including an extended citation of relevant literature data.

  3. Role of myocardial perfusion SPECT in asymptomatic diabetic patients

    International Nuclear Information System (INIS)

    Cho, I.; Chun, K.; Won, K.; Lee, H.; Park, J.; Shin, D.; Kim, Y.; Shim, B.; Lee, J.

    2002-01-01

    Purpose: It is important that early diagnosis and treatment of coronary artery disease in diabetic patients, but there are few reports on the prevalence of stress-induced myocardial perfusion abnormalities and the rates of cardiac event in patients with type 2 diabetes. We evaluated the scan findings on gated myocardial perfusion SPECT in asymptomatic diabetic patients. Methods: We performed pharmacological stress test and gated perfusion SPECT in 69 diabetic patients without cardiovascular symptom (mean age: 65 year, male 31 and female 38). Patients underwent two-day imaging protocol and stress study was performed injection of Tc-99m MIBI during adenosine infusion. We followed up these patients by reviewing medical records. Results: Fifty-two of 69 patients (74.5%) showed normal scan findings and 17 patients (24.6%) showed reversible or fixed perfusion defects. Three of 52 patients with normal scan findings showed decreased LV ejection fraction and decreased wall motion. Twenty-three patients with normal scan findings were possible to follow up for more than 1yr (mean time: 18.3±3.3 mo.) and they all had no cardiac event. Three patients with reversible perfusion defects were performed coronary angioplasty. Conclusion: Myocardial perfusion SPECT is a noninvasive method and maybe useful in early diagnosis and predicting prognosis in diabetic patients

  4. A noninvasive estimation of cerebral perfusion pressure using critical closing pressure.

    Science.gov (United States)

    Varsos, Georgios V; Kolias, Angelos G; Smielewski, Peter; Brady, Ken M; Varsos, Vassilis G; Hutchinson, Peter J; Pickard, John D; Czosnyka, Marek

    2015-09-01

    Cerebral blood flow is associated with cerebral perfusion pressure (CPP), which is clinically monitored through arterial blood pressure (ABP) and invasive measurements of intracranial pressure (ICP). Based on critical closing pressure (CrCP), the authors introduce a novel method for a noninvasive estimator of CPP (eCPP). Data from 280 head-injured patients with ABP, ICP, and transcranial Doppler ultrasonography measurements were retrospectively examined. CrCP was calculated with a noninvasive version of the cerebrovascular impedance method. The eCPP was refined with a predictive regression model of CrCP-based estimation of ICP from known ICP using data from 232 patients, and validated with data from the remaining 48 patients. Cohort analysis showed eCPP to be correlated with measured CPP (R = 0.851, p area under the curve of 0.913 (95% CI 0.883-0.944). When each recording session of a patient was assessed individually, eCPP could predict CPP with a 95% CI of the SD for estimating CPP between multiple recording sessions of 1.89-5.01 mm Hg. Overall, CrCP-based eCPP was strongly correlated with invasive CPP, with sensitivity and specificity for detection of low CPP that show promise for clinical use.

  5. Evaluation of portal hypertension: a comparison of the use of liver perfusion CT with wedge hepatic venous pressure and hepatic

    International Nuclear Information System (INIS)

    Chung, Dong Jin; Kim, Young Joong; Park, Yong Sung; Lee, Tae Hee; Kim, Chong Soo; Kang, Heung Keun

    2008-01-01

    We compared the hepatic perfusion indices obtained using hepatic perfusion CT with the wedge hepatic venous pressure (WHVP) and hepatic venous pressure gradient (HVPG) to determine the efficacy of the use of liver perfusion CT for the evaluation of portal hypertension. Thirty-five patients with liver cirrhosis underwent hepatic vein catheterization to measure WHVP and HVPG and underwent a liver perfusion CT examination. Arterial perfusion, portal perfusion, total perfusion and the hepatic perfusion index (HPI) were calculated by the methods described by Miles and Blomlely. The overall correlation coefficients (r) between the perfusion indices and WHVP and HVPG were calculated. An additional correlation coefficient of 23 alcoholic cirrhosis patients was calculated. Using Blomley's equation, HPI had a positive correlation with WHVP (r = .471; ρ < .05) and HVPG (r = .482; ρ < .05). For the alcoholic liver cirrhosis patients, HPI had a higher positive correlation with WHVP (r = .500; ρ < .05) and HVPG (r = .539; ρ < .05) than for the non-alcoholic cirrhosis patients. There was no statistical difference between the use of Miles' equation and Blomley's equation for the evaluation of portal hypertension. This preliminary study showed that HPI positively correlated with WHVP and HVPG, especially in alcoholic cirrhosis patients. Liver perfusion CT may be useful in the evaluation of portal hypertension

  6. Prognostic value of abnormal exercise myocardial perfusion imaging and its types in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Zhu Mei; Pan Zhongyun; Lin JInghui; Zhang Chunli; Nie Tao; Wang Yanfu

    1998-01-01

    Purpose: To evaluate the prognostic value of abnormal exercise myocardial perfusion imaging and its types in patients with coronary artery disease (CAD). Methods: 69 patients with CAD underwent exercise myocardial perfusing imaging and exercise ECG test. The images of all of them were abnormal. 45 patients were angiographically proved CAD. Follow-up period ranged from 6∼110 months and even longer than 12 months for patients with no cardiac events (CE). Results: CE occurred in 15 patients during the follow-up period. The CE incidence was 8.7% per year. Cox regression analysis revealed that there was a good correlation between the number of myocardial segments with reversible defects and future CE. Comparing the results of 13 patients with small extent irreversible defects with the data obtained from normal subjects reported previously, there was no significant difference between two no-CE rates (x 2 = 0.09, P>0.05). Conclusions: Normal myocardial images and irreversible defects involving rather small areas predicted an excellent prognosis. The better predictor of future CE is the quantity of myocardial segments with reversible defect

  7. Qualitative Resting Coronary Pressure Wave Form Analysis to Predict Fractional Flow Reserve.

    Science.gov (United States)

    Matsumura, Mitsuaki; Maehara, Akiko; Johnson, Nils P; Fearon, William F; De Bruyne, Bernard; Oldroyd, Keith G; Pijls, Nico H J; Jenkins, Paul; Ali, Ziad A; Mintz, Gary S; Stone, Gregg W; Jeremias, Allen

    2018-03-27

    To evaluate the predictability of resting distal coronary pressure wave forms for fractional flow reserve (FFR). Resting coronary wave forms were qualitatively evaluated for the presence of (i) dicrotic notch; (ii) diastolic dipping; and (iii) ventricularization. In a development cohort (n=88) a scoring system was developed that was then applied to a validation cohort (n=428) using a multivariable linear regression model to predict FFR and receiver operating characteristics (ROC) to predict FFR ≤0.8. In the development cohort, all 3 qualitative parameters were independent predictors of FFR. However, in a multivariable linear regression model in the validation cohort, qualitative wave form analysis did not further improve the ability of resting distal coronary to aortic pressure ratio (Pd/Pa) (p=0.80) or instantaneous wave-free ratio (iFR) (p=0.26) to predict FFR. Using ROC, the area under the curve of resting Pd/Pa (0.86 versus 0.86, P=0.08) and iFR (0.86 versus 0.86, P=0.26) did not improve by adding qualitative analysis. Qualitative coronary wave form analysis showed moderate classification agreement in predicting FFR but did not add substantially to the resting pressure gradients Pd/Pa and iFR; however, when discrepancies between quantitative and qualitative analyses are observed, artifact or pressure drift should be considered.

  8. Perfusion Computed Tomography for the Assessment of Myocardial Viability — a Case Series

    Directory of Open Access Journals (Sweden)

    Morariu Mirabela

    2016-06-01

    Full Text Available Myocardial viability plays an important role in preventing the development of left ventricular remodeling following an acute myocardial infarction. A preserved viability in the infarcted area has been demonstrated to be associated with a lower amplitude of the remodeling process, while the extent of the non-viable myocardium is directly correlated with the amplitude of the remodeling process. A number of methods are currently in use for the quantification of the viable myocardium, and some of them are based on the estimation of myocardial perfusion during pharmacologic stress. 64-slice Multi-detector Computed Tomography (MDCT during vasodilator stress test, associated with CT Coronary Angiography (CCTA has a high diagnostic accuracy in evaluating myocardial perfusion. In this article, we present a sequence of 3 clinical cases that presented with symptoms of myocardial ischemia, who underwent 64-slice MDCT imaging at rest and during adenosine stress test, in order to assess the extent of the hypoperfused myocardial areas. Coronary artery anatomy and the Coronary Calcium Score was assessed for all 3 patients by performing CT Coronary Angiography. The combination of CT Angiography and adenosine stress CT myocardial perfusion imaging can accurately detect atherosclerosic lesions that cause perfusion abnormalities, compared with the combination of invasive angiography and single-photon emission computed tomography (SPECT.

  9. Quantitative Myocardial Perfusion Imaging Versus Visual Analysis in Diagnosing Myocardial Ischemia: A CE-MARC Substudy.

    Science.gov (United States)

    Biglands, John D; Ibraheem, Montasir; Magee, Derek R; Radjenovic, Aleksandra; Plein, Sven; Greenwood, John P

    2018-05-01

    This study sought to compare the diagnostic accuracy of visual and quantitative analyses of myocardial perfusion cardiovascular magnetic resonance against a reference standard of quantitative coronary angiography. Visual analysis of perfusion cardiovascular magnetic resonance studies for assessing myocardial perfusion has been shown to have high diagnostic accuracy for coronary artery disease. However, only a few small studies have assessed the diagnostic accuracy of quantitative myocardial perfusion. This retrospective study included 128 patients randomly selected from the CE-MARC (Clinical Evaluation of Magnetic Resonance Imaging in Coronary Heart Disease) study population such that the distribution of risk factors and disease status was proportionate to the full population. Visual analysis results of cardiovascular magnetic resonance perfusion images, by consensus of 2 expert readers, were taken from the original study reports. Quantitative myocardial blood flow estimates were obtained using Fermi-constrained deconvolution. The reference standard for myocardial ischemia was a quantitative coronary x-ray angiogram stenosis severity of ≥70% diameter in any coronary artery of >2 mm diameter, or ≥50% in the left main stem. Diagnostic performance was calculated using receiver-operating characteristic curve analysis. The area under the curve for visual analysis was 0.88 (95% confidence interval: 0.81 to 0.95) with a sensitivity of 81.0% (95% confidence interval: 69.1% to 92.8%) and specificity of 86.0% (95% confidence interval: 78.7% to 93.4%). For quantitative stress myocardial blood flow the area under the curve was 0.89 (95% confidence interval: 0.83 to 0.96) with a sensitivity of 87.5% (95% confidence interval: 77.3% to 97.7%) and specificity of 84.5% (95% confidence interval: 76.8% to 92.3%). There was no statistically significant difference between the diagnostic performance of quantitative and visual analyses (p = 0.72). Incorporating rest myocardial

  10. Tensile strength decreases and perfusion pressure of 3-holed polyamide epidural catheters increases in long-term epidural infusion.

    Science.gov (United States)

    Kim, Pascal; Meyer, Urs; Schüpfer, Guido; Rukwied, Roman; Konrad, Christoph; Gerber, Helmut

    2011-01-01

    Epidural analgesia is an established method for pain management. The failure rate is 8% to 12% due to technical difficulties (catheter dislocation and/or disconnection; partial or total catheter occlusion) and management. The mechanical properties of the catheters, like tensile strength and flow rate, may also be affected by the analgesic solution and/or the tissue environment. We investigated the tensile strength and perfusion pressure of new (n=20), perioperatively (n=30), and postoperatively (n=73) used epidural catheters (20-gauge, polyamide, closed tip, 3 side holes; Perifix [B. Braun]). To prevent dislocation, epidural catheters were taped (n=5) or fixed by suture (n=68) to the skin. After removal, mechanical properties were assessed by a tensile-testing machine (INSTRON 4500), and perfusion pressure was measured at flow rates of 10, 20, and 40 mL/h. All catheters demonstrated a 2-step force transmission. Initially, a minimal increase of length could be observed at 15 N followed by an elongation of several cm at additional forces (7 N). Breakage occurred in the control group at 23.5±1.5 N compared with 22.4±1.6 N in perioperative and 22.4±1.7 N in postoperative catheters (Ptensile strength, whereas perfusion pressure at clinically used flow rates (10 mL/h) increased significantly from 19±1.3 to 44±72 mm Hg during long-term (≥7 days) epidural analgesia (Ptensile strength or perfusion pressure. Epidural catheter use significantly increases the perfusion pressure and decreases the tensile strength. Copyright © 2011 by American Society of Regional Anesthesia and Pain Medicine

  11. Percutaneous coronary intervention for poor coronary microcirculation reperfusion of patients with stable angina pectoris.

    Science.gov (United States)

    Li, J S; Zhao, X J; Ma, B X; Wang, Z

    2016-01-01

    Percutaneous coronary intervention (PCI) has been extensively applied to repair the forward flow of diseased coronary artery and can achieve significant curative results. However, some patients with acute myocardial infarction (AMI) develop non-perfusion or poor perfusion of cardiac muscle tissue after PCI, which increases the incidence of cardiovascular events and the death rate. PCI can dredge narrowed or infarct-related artery (IRA) and thus induce full reperfusion of ischemic myocardium. It is found in practice that some cases of AMI still have no perfusion or poor perfusion in myocardial tissue even though coronary angiography suggests opened coronary artery after PCI, which increases the incidence of vascular events and mortality. Therefore, to explore the detailed mechanism of PCI in treating coronary microcirculation of patients with stable angina pectoris, we selected 140 patients with stable angina pectoris for PCI, observing the index of microcirculatory resistance (IMR) of descending branch and changes of myocardial injury markers and left ventricular systolic function, and made a subgroup analysis based on the correlation between clinical indexes, IMR and other variables of diabetic and non-diabetic patients, PCI-related and non-PCI-related myocardial infarction patients. The results suggest that IMR of anterior descending branch after PCI was higher compared to that before PCI, and the difference was significant (P less than 0.05); creatine kinase-MB (CK-MB), myohemoglobin and high sensitive troponin T were all increased after PCI, and the difference was also significant (P less than 0.05); brain natriuretic peptide (BNP) level became higher after PCI, with significant difference (P less than 0.05); left ventricular ejection fraction (LVEF) declined after PCI, and the difference before and after PCI was statistically significant (P less than 0.05). Moreover, subgroup analysis results of the three groups all demonstrated statistically significant

  12. Cerebral perfution studies; Estudios de Perfusion Cerebral

    Energy Technology Data Exchange (ETDEWEB)

    Mut, Fernando [Universidad de la Republica, Montevideo (Uruguay). Centro de Medicina Nuclear

    1994-12-31

    For detecting in precocious form a coronary disease is necessary to aply a diagnostic techniques. The main considerations to be indicated in the present work are: physiological considerations, myocardial perfusion studies with radiotracers such as Talio 201, 99mTc, MIBI, 99mTc-Teboroxima, 99mTc-Fosfinas, instrumentation for obtain good images, proceedings protocols, studies interpretation, standards, SPECT, anomalies standards, coronary diseases.

  13. Stress-only myocardial perfusion scintigraphy: a prospective study on the accuracy and observer agreement with quantitative coronary angiography as the gold standard.

    Science.gov (United States)

    Ejlersen, June A; May, Ole; Mortensen, Jesper; Nielsen, Gitte L; Lauridsen, Jeppe F; Allan, Johansen

    2017-11-01

    Patients with normal stress perfusion have an excellent prognosis. Prospective studies on the diagnostic accuracy of stress-only scans with contemporary, independent examinations as gold standards are lacking. A total of 109 patients with typical angina and no previous coronary artery disease underwent a 2-day stress (exercise)/rest, gated, and attenuation-corrected (AC), 99m-technetium-sestamibi perfusion study, followed by invasive coronary angiography. The stress datasets were evaluated twice by four physicians with two different training levels (expert and novice): familiar and unfamiliar with AC. The two experts also made a consensus reading of the integrated stress-rest datasets. The consensus reading and quantitative data from the invasive coronary angiography were applied as reference methods. The sensitivity/specificity were 0.92-1.00/0.73-0.90 (reference: expert consensus reading), 0.93-0.96/0.63-0.82 (reference: ≥1 stenosis>70%), and 0.75-0.88/0.70-0.88 (reference: ≥1 stenosis>50%). The four readers showed a high and fairly equal sensitivity independent of their familiarity with AC. The expert familiar with AC had the highest specificity independent of the reference method. The intraobserver and interobserver agreements on the stress-only readings were good (readers without AC experience) to excellent (readers with AC experience). AC stress-only images yielded a high sensitivity independent of the training level and experience with AC of the nuclear physician, whereas the specificity correlated positively with both. Interobserver and intraobserver agreements tended to be the best for physicians with AC experience.

  14. Improvement of myocardial perfusion detected by 201Tl scintigraphy on cardiac rehabilitation for patients with coronary artery disease

    International Nuclear Information System (INIS)

    Li, Linxue; Nohara, Ryuji; Makita, Shigeru

    1996-01-01

    The effect of cardiac rehabilitation (mean 70±48 months) on myocardial perfusion was assessed using thallium-201 ( 201 Tl) exercise study in 63 patients with coronary artery disease (CAD). Subjects were those in a rehabilitation group (Rh=42) participating in supervised sports training two to three times per week and the control group (Ct=21) not taking active daily exercise. The interval between two 201 Tl SPECT studies was 19±16 months. After physical training, total duration of the exercise test increased from 443±112 to 536±121 seconds (+19%) in the Rh group, and from 484±129 to 432±115 seconds in the Ct group (-10.7%) (p 2 to 269.8±58 x 10 2 in the Rh group and decreased from 218.7±40 x 10 2 to 216.6±76 x 10 2 (p 201 Tl myocardial perfusion defect on exercise improved more in 54.8% (stress 59.5%, rest 35.7%) in the Rh group than in the Ct group (9.5%, p 201 Tl perfusion defect decreased from 68 (23.1%) to 49 regions (16.7%) of 294 total myocardial regions in the Rh group on exercise. However. it increased from 39 (26.5%) to 44 (29.9%) regions of 147 regions in the Ct group (p<0.01). Thus, cardiac rehabilitation increases exercise tolerance with improvement of myocardial perfusion. suggesting that cardiac rehabilitation is an advisable and effective treatment for patients with ischemic heart disease. (author)

  15. Functional Relevance of Coronary Artery Disease by Cardiac Magnetic Resonance and Cardiac Computed Tomography: Myocardial Perfusion and Fractional Flow Reserve

    Directory of Open Access Journals (Sweden)

    Gianluca Pontone

    2015-01-01

    Full Text Available Coronary artery disease (CAD is one of the leading causes of morbidity and mortality and it is responsible for an increasing resource burden. The identification of patients at high risk for adverse events is crucial to select those who will receive the greatest benefit from revascularization. To this aim, several non-invasive functional imaging modalities are usually used as gatekeeper to invasive coronary angiography, but the diagnostic yield of elective invasive coronary angiography remains unfortunately low. Stress myocardial perfusion imaging by cardiac magnetic resonance (stress-CMR has emerged as an accurate technique for diagnosis and prognostic stratification of the patients with known or suspected CAD thanks to high spatial and temporal resolution, absence of ionizing radiation, and the multiparametric value including the assessment of cardiac anatomy, function, and viability. On the other side, cardiac computed tomography (CCT has emerged as unique technique providing coronary arteries anatomy and more recently, due to the introduction of stress-CCT and noninvasive fractional flow reserve (FFR-CT, functional relevance of CAD in a single shot scan. The current review evaluates the technical aspects and clinical experience of stress-CMR and CCT in the evaluation of functional relevance of CAD discussing the strength and weakness of each approach.

  16. Blood pressure reactivity to psychological stress and coronary calcification in the Coronary Artery Risk Development in Young Adults Study.

    Science.gov (United States)

    Matthews, Karen A; Zhu, Sha; Tucker, Diane C; Whooley, Mary A

    2006-03-01

    A longstanding hypothesis is that individuals who exhibit large increases in blood pressure during psychological stress are at risk for atherosclerosis. We tested whether blood pressure changes during psychological stress predict subsequent coronary calcification (CaC) in young healthy adults. We evaluated 2816 healthy black and white women, 20 to 35 years of age, from the Coronary Artery Risk Development in Young Adults Study, who were not using medication for hypertension or diabetes in 1987-1988. Participants completed video game and star tracing tasks while their blood pressure was recorded. Thirteen years later (2000-2001), they completed computed tomography measures of CaC. Overall 9.3% (261 of 2816) had CaC present at follow-up. Each 10 mm Hg change in systolic blood pressure during the video game was associated with a 24% increased odds of having CaC at follow-up (unadjusted odds ratio, 1.24; 95% CI, 1.06 to 1.46; P=0.008). This association persisted after adjustment for age, race, sex, education, smoking, alcohol, family history of myocardial infarction, smoking, daily alcohol consumption, body mass index, and resting or baseline blood pressure (odds ratio, 1.31; 95% CI, 1.08 to 1.58; P=0.006). Blood pressure changes during the star tracing task were not associated with subsequent CaC. Blood pressure changes during a video game predicted the presence of CaC 13 years later. To our knowledge, this is the first study that reports blood pressure reactivity to a stressor being related to calcification in the coronary arteries. Blood pressure reactivity may provide useful prognostic information about future risk beyond standard risk factors.

  17. Ocular Perfusion Pressure and Pulsatile Ocular Blood Flow in Normal and Systemic Hypertensive Patients.

    Science.gov (United States)

    Kanadani, Fabio N; Figueiredo, Carlos R; Miranda, Rafaela Morais; Cunha, Patricia Lt; M Kanadani, Tereza Cristina; Dorairaj, Syril

    2015-01-01

    Glaucomatous neuropathy can be a consequence of insufficient blood supply, increase in intraocular pressure (IOP), or other risk factors that diminish the ocular blood flow. To determine the ocular perfusion pressure (OPP) in normal and systemic hypertensive patients. One hundred and twenty-one patients were enrolled in this prospective and comparative study and underwent a complete ophthalmologic examination including slit lamp examination, Goldmann applanation tonometry, stereoscopic fundus examination, and pulsatile ocular blood flow (POBF) measurements. The OPP was calculated as being the medium systemic arterial pressure (MAP) less the IOP. Only right eye values were considered for calculations using Student's t-test. The mean age of the patients was 57.5 years (36-78), and 68.5% were women. There was a statistically significant difference in the OPP of the normal and systemic hypertensive patients (p cite this article: Kanadani FN, Figueiredo CR, Miranda RM, Cunha PLT, Kanadani TCM, Dorairaj S. Ocular Perfusion Pressure and Pulsatile Ocular Blood Flow in Normal and Systemic Hypertensive Patients. J Curr Glaucoma Pract 2015;9(1):16-19.

  18. SPECT myocardial perfusion imaging. Long-term prognostic value in diabetic patients with and without coronary artery disease

    International Nuclear Information System (INIS)

    Koehli, M.; Monbaron, D.; Gaillard, R.C.; Ruiz, J.; Prior, J.O.; Bischof Delaloye, A.; Calcagni, M.L.; Fivaz-Arbane, M.; Stauffer, J.C.

    2006-01-01

    Aim: To determine the long-term prognostic value of SPECT myocardial perfusion imaging (MPI) for the occurrence of cardiovascular events in diabetic patients. Patients, methods: SPECT MPI of 210 consecutive Caucasian diabetic patients were analysed using Kaplan-Meier event-free survival curve and independent predictors were determined by Cox multivariate analyses. Results: Follow-up was complete in 200 (95%) patients with a median period of 3.0 years (0.8-5.0). The population was composed of 114 (57%) men, age 65 ± 10 years, 181 (90.5%) type 2 diabetes mellitus, 50 (25%) with a history of coronary artery disease (CAD) and 98 (49%) presenting chest pain prior to MPI. The prevalence of abnormal MPI was 58%. Patients with a normal MPI had neither cardiac death, nor myocardial infarction, independently of a history of coronary artery disease or chest pain. Among the independent predictors of cardiac death and myocardial infarction, the strongest was abnormal MPI (p 5-fold increase in cardiovascular events. This emphasizes the value of SPECT MPI in predicting and risk-stratifying cardiovascular events in diabetic patients. (orig.)

  19. Long-term cigarette smoking is associated with increased myocardial perfusion heterogeneity assessed by positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Meeder, J.G. [Department of Cardiology and National Research PET Center, University Hospital, Groningen (Netherlands); Blanksma, P.K. [Department of Cardiology and National Research PET Center, University Hospital, Groningen (Netherlands); Wall, E.E. van der [Department of Cardiology, University Hospital, Leiden (Netherlands); Anthonio, R.L. [Department of Cardiology and National Research PET Center, University Hospital, Groningen (Netherlands); Willemsen, A.T.M. [Department of Cardiology and National Research PET Center, University Hospital, Groningen (Netherlands); Pruim, J. [Department of Cardiology and National Research PET Center, University Hospital, Groningen (Netherlands); Vaalburg, W. [Department of Cardiology and National Research PET Center, University Hospital, Groningen (Netherlands); Lie, K.I. [Department of Cardiology and National Research PET Center, University Hospital, Groningen (Netherlands)

    1996-11-01

    The pathophysiology of smoking-related coronary events in patients with normal coronary arteries is incompletely understood. This study was conducted to explore, in subjects without symptoms of cardiovascular disease, the long-term effects of smoking on regional coronary artery vasoactivity, especially during sympathetic stimulation. In ten smoking and ten non-smoking sex- and age-matched healthy volunteers, segmental myocardial perfusion was studied using dynamic parametric nitrogen-13 ammonia positron emission tomography at rest and during sympathetic stimulation evoked by the cold pressor stimulation. Smokers demonstrated a higher myocardial perfusion at rest (116{+-}17 ml/min/100 g vs 96{+-}20 ml/min/100 g, P <0.01) and an impaired myocardial perfusion increase during cold pressor stimulation (1.02{+-}0.15 vs 1.18{+-}0.17, P <0.05). The heterogeneity of perfusion, expressed as coefficient of variation, was significantly different between the smoking and the non-smoking group. The coefficient of variation of segmental myocardial perfusion was higher in smokers at rest (17.5%{+-}4.2% vs 13.5%{+-}1.9%, P <0.05) and during cold pressor stimulation (17.0%{+-}3.2% vs 13.9%{+-}1.8%, P <0.05). We conclude that the long-term effects of smoking in healthy volunteers are associated with (1) increased myocardial perfusion at rest, (2) impaired myocardial perfusion response to cold pressor stimulation, and (3) increased myocardial perfusion heterogeneity both at rest and during cold pressor stimulation. These results may suggest that in healthy subjects the long-term effect of smoking is related to abnormal coronary artery vasoactivity, presumably induced by an interplay of regional endothelial dysfunction and autonomic dysregulation. (orig.). With 1 fig., 1 tab.

  20. Evaluation of portal hypertension: a comparison of the use of liver perfusion CT with wedge hepatic venous pressure and hepatic

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Dong Jin; Kim, Young Joong; Park, Yong Sung; Lee, Tae Hee [University of Konyang College of Medicine, Daejeon (Korea, Republic of); Kim, Chong Soo; Kang, Heung Keun [Chonbuk National University Medical School, Jeonju (Korea, Republic of)

    2008-09-15

    We compared the hepatic perfusion indices obtained using hepatic perfusion CT with the wedge hepatic venous pressure (WHVP) and hepatic venous pressure gradient (HVPG) to determine the efficacy of the use of liver perfusion CT for the evaluation of portal hypertension. Thirty-five patients with liver cirrhosis underwent hepatic vein catheterization to measure WHVP and HVPG and underwent a liver perfusion CT examination. Arterial perfusion, portal perfusion, total perfusion and the hepatic perfusion index (HPI) were calculated by the methods described by Miles and Blomlely. The overall correlation coefficients (r) between the perfusion indices and WHVP and HVPG were calculated. An additional correlation coefficient of 23 alcoholic cirrhosis patients was calculated. Using Blomley's equation, HPI had a positive correlation with WHVP (r = .471; {rho} < .05) and HVPG (r = .482; {rho} < .05). For the alcoholic liver cirrhosis patients, HPI had a higher positive correlation with WHVP (r = .500; {rho} < .05) and HVPG (r = .539; {rho} < .05) than for the non-alcoholic cirrhosis patients. There was no statistical difference between the use of Miles' equation and Blomley's equation for the evaluation of portal hypertension. This preliminary study showed that HPI positively correlated with WHVP and HVPG, especially in alcoholic cirrhosis patients. Liver perfusion CT may be useful in the evaluation of portal hypertension.

  1. The clinical value of planar thallium-201 myocardial perfusion scintigraphy

    International Nuclear Information System (INIS)

    Niemeyer, M.G.

    1989-01-01

    The clinical value of planar thalium-201 myocardial perfusion scintigraphy was examined, using visual and quantitative analysis, for the detection of presence, localization and extent of coronary disease, using coronary arteriography as gold standard. The indremental diagnostic yield of different noninvasive tests for the diagnosis and the severity of coronary artery disease was quantified by using multivariate discriminant analysis. (author). 284 refs.; 14 figs.; 37 tabs

  2. Improved Accuracy of Myocardial Perfusion SPECT for the Detection of Coronary Artery Disease by Utilizing a Support Vector Machines Algorithm

    Science.gov (United States)

    Arsanjani, Reza; Xu, Yuan; Dey, Damini; Fish, Matthews; Dorbala, Sharmila; Hayes, Sean; Berman, Daniel; Germano, Guido; Slomka, Piotr

    2012-01-01

    We aimed to improve the diagnostic accuracy of automatic myocardial perfusion SPECT (MPS) interpretation analysis for prediction of coronary artery disease (CAD) by integrating several quantitative perfusion and functional variables for non-corrected (NC) data by support vector machines (SVM), a computer method for machine learning. Methods 957 rest/stress 99mtechnetium gated MPS NC studies from 623 consecutive patients with correlating invasive coronary angiography and 334 with low likelihood of CAD (LLK < 5% ) were assessed. Patients with stenosis ≥ 50% in left main or ≥ 70% in all other vessels were considered abnormal. Total perfusion deficit (TPD) was computed automatically. In addition, ischemic changes (ISCH) and ejection fraction changes (EFC) between stress and rest were derived by quantitative software. The SVM was trained using a group of 125 pts (25 LLK, 25 0-, 25 1-, 25 2- and 25 3-vessel CAD) using above quantitative variables and second order polynomial fitting. The remaining patients (N = 832) were categorized based on probability estimates, with CAD defined as (probability estimate ≥ 0.50). The diagnostic accuracy of SVM was also compared to visual segmental scoring by two experienced readers. Results Sensitivity of SVM (84%) was significantly better than ISCH (75%, p < 0.05) and EFC (31%, p < 0.05). Specificity of SVM (88%) was significantly better than that of TPD (78%, p < 0.05) and EFC (77%, p < 0.05). Diagnostic accuracy of SVM (86%) was significantly better than TPD (81%), ISCH (81%), or EFC (46%) (p < 0.05 for all). The Receiver-operator-characteristic area-under-the-curve (ROC-AUC) for SVM (0.92) was significantly better than TPD (0.90), ISCH (0.87), and EFC (0.60) (p < 0.001 for all). Diagnostic accuracy of SVM was comparable to the overall accuracy of both visual readers (85% vs. 84%, p < 0.05). ROC-AUC for SVM (0.92) was significantly better than that of both visual readers (0.87 and 0.88, p < 0.03). Conclusion Computational

  3. Myocardial perfusion SPECT imaging in patients with myocardial bridging

    International Nuclear Information System (INIS)

    Fang Wei; Qiu Hong; Yang Weixian; Wang Feng; He Zuoxiang

    2008-01-01

    Objective: Stress myocardial perfusion SPECT imaging was used to assess myocardial ischemia in patients with myocardial bridging. Methods: Ninety-six patients with myocardial bridging of the left anterior descending artery documented by coronary angiography were included in this study. All under- went exercise or pharmacological stress myocardial perfusion SPECT assessing myocardial ischemia. None had prior myocardial infarction. One year follow-up by telephone interview was performed in all patients. Results The mean stenotic severity of systolic phase on angiography was (65 ± 19)%. In the SPECT study, 20 of 96 (20.8%) patients showed abnormal perfusion. This percentage was significantly higher than that of stress electrocardiogram (ECG). The higher positive rate of SPECT perfusion images was showed in the group of patients with severe systolic narrowing (≥75%) than that with mild-to-moderate systolic narrowing (50% vs 6.3%, P<0.001). The prevalence of abnormal image was significantly higher in ELDERLY PEOPLE; patients with STT change on rest ECG than in those with normal rest ECG (54.2% vs 9.7%, P<0.001). During follow-up, one patient with abnormal SPECT perfusion image sustained angina and accepted percutaneous coronary intervention, and no cardiac event occurred in patients with normal images. Conclusions: Stress myocardial perfusion SPECT imaging can be used effectively for assessing myocardial ischemia and has potential prognostic value for patients with myocardial bridging. (authors)

  4. Resting cardiointegram: correlation with stress thallium perfusion studies

    International Nuclear Information System (INIS)

    Gould, L.A.; Betzu, R.; Judge, D.; Lee, J.; Taddeo, M.; Yang, D.

    1988-01-01

    The cardiointegram is a noninvasive technique for the analysis of the electrical signals of the heart obtained by a transformation of the voltage versus time format by a series of integrations. The stress thallium perfusion study is a widely used test for the detection of coronary artery disease. In order to evaluate the correlation between the resting cardiointegram and the stress thallium 201 perfusion study, 20 patients with normal resting electrocardiograms underwent stress thallium tests and resting cardiointegrams. The cardiointegram was determined on two resting complexes of leads I, II, V4, V5, and V6 and called abnormal if five of ten complexes deviated outside a normalized template. There was concordance of the cardiointegram and the thallium study in 16 of 20 patients (80%). The sensitivity for the detection of coronary artery disease was 71%, and the specificity was 80%. The overall accuracy was 74%. Thus in patients with normal electrocardiograms, the cardiointegram is a useful noninvasive test for the detection of coronary artery disease

  5. Clinical significance of inter-arm pressure difference and ankle-brachial pressure index in patients with suspected coronary artery disease

    International Nuclear Information System (INIS)

    Igarashi, Yuko; Chikamori, Taishiro; Tomiyama, Hirofumi; Usui, Yasuhiro; Hida, Satoshi; Tanaka, Hirokazu; Nagao, Tadashi; Yamashina, Akira

    2007-01-01

    Although measuring blood pressure at the bilateral brachia is common in medical practice, its clinical significance in patients with suspected coronary artery disease (CAD) has not been fully clarified. The method of this study was to define the significance of inter-arm systolic blood pressure difference in patients with suspected CAD, and to assess the relationship between inter-arm pressure difference and CAD, simultaneous brachial and ankle blood pressure measurements and stress myocardial single-photon emission computed tomography (SPECT) were performed in 386 consecutive patients with suspected CAD, excluding those with previous myocardial infarction or coronary revascularization. Subclavian artery stenosis, defined as ≥15 mmHg inter-arm systolic blood pressure difference, was found in 27 patients (7%). Age (65±12 vs 65±11 years), male sex (21/27 vs 244/359), prevalence of hypertension (63% vs 56%), hypercholesterolemia (63% vs 62%), diabetes mellitus (33% vs 38%), cigarette smoking (44% vs 41%) and family history of CAD (15% vs 12%) were similar between patients with subclavian artery stenosis and those without. The incidence of decreased ankle-brachial pressure index (ABI) was higher (37% vs 12%, p=0.001), and percentage ischemic myocardium as assessed by SPECT was greater (9.0±8.5% vs 5.6±6.6%, p=0.05) in patients with subclavian artery stenosis than in those without. Furthermore, significant correlations were observed between inter-arm pressure difference and percentage ischemic myocardium (r=0.13; p=0.01), and ABI (r=-0.26, p<0.0001). Among 386 patients, 283 underwent coronary angiography, and 63% of those who had inter-arm blood pressure difference had CAD. Furthermore, 83% of those CAD patients had multi-vessel CAD, which is regarded as a high-risk subset for subsequent cardiac events. Inter-arm pressure difference is often found in patients with suspected CAD, and is associated with significant CAD and peripheral artery disease. Thus, inter

  6. New possibilities in the diagnosis of ischemia. CT-FFR and CT-Perfusion; Neue Moeglichkeiten der Ischaemiediagnostik. CT-FFR und CT-Perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Lehmkuhl, Lukas [Herz- und Gefaessklinik, Bad Neustadt an der Saale (Germany). Abt. fuer Radiologie; Krieghoff, Christian [Herzzentrum Leipzig (Germany); Gutberlet, Matthias [Herzzentrum Leipzig (Germany). Abt. fuer Diagnostische und Interventionelle Radiologie; Leipzig Univ. (Germany). Kardiologische Bildgebung

    2017-12-15

    Coronary CT-angiography (CCTA) plays an increasing role in the primary diagnostics of coronary artery disease (CAD) according to the present guidelines but also in clinical reality. The sensitivity and negative predictive value of CCTA is very high, but the specificity could still be improved. Newer techniques to assess myocardial ischemia like CT-FFR and CT-Perfusion may help to achieve that goal.

  7. Coronary artery stenosis and occlusion: value of 99Tcm-MIBI SPECT

    International Nuclear Information System (INIS)

    Gyoengyoesi, M.; Maul, F.-D.; Standke, R.; Klepzig, H. Jr.; Kaltenbach, M.; Hoer, G.

    1994-01-01

    The aim of this study was to evaluate and validate a new quantification method for 99 Tc m -sestamibi single photon emission computed tomographic (SPECT) myocardial imaging based on a four-slice analysis method and to check the functional results of percutaneous transluminal coronary angioplasty (PTCS). Using the calculated pathological area of the scintigram as an index for myocardial ischaemia, the overall sensitivity was 81-90% and the overall specificity was 74-98%. Analysis of variance of the repeated measurements revealed good reproducibility (coefficient of variation 8.4%). A significant correlation was found between the size of the exercise-induced perfusion defects and the degree of coronary stenosis. The comparison of radionuclide ventriculography and the perfusion image in 27 patients revealed a good correlation between the resting global ejection fraction and myocardial perfusion, but there was no correlation during exercise, indicating a dissociation between myocardial perfusion and function during exercise conditions in patients with coronary artery disease (CAD). (author)

  8. Perfusion of veins at arterial pressure increases the expression of KLF5 and cell cycle genes in smooth muscle cells

    International Nuclear Information System (INIS)

    Amirak, Emre; Zakkar, Mustafa; Evans, Paul C.; Kemp, Paul R.

    2010-01-01

    Vascular smooth muscle cell (VSMC) proliferation remains a major cause of veno-arterial graft failure. We hypothesised that exposure of venous SMCs to arterial pressure would increase KLF5 expression and that of cell cycle genes. Porcine jugular veins were perfused at arterial or venous pressure in the absence of growth factors. The KLF5, c-myc, cyclin-D and cyclin-E expression were elevated within 24 h of perfusion at arterial pressure but not at venous pressure. Arterial pressure also reduced the decline in SM-myosin heavy chain expression. These data suggest a role for KLF5 in initiating venous SMCs proliferation in response to arterial pressure.

  9. Clinical value of atropine-four minutes adenosine stressed 99Tcm-MIBI myocardial perfusion imaging in the diagnosis of coronary artery disease

    International Nuclear Information System (INIS)

    Peng Xulan; Zhang Baoniu; Jiang Sufang; Liang Hongwei; Liu Jun; Gao Guizhu; Ding Minghui; Hou Junfu

    2008-01-01

    Objective: The aim of this study was to compare the diagnostic efficacy of atropine-4 min adenosine stressed 99 Tc m -methoxyisobutylisonitrile (MIBI) myocardial perfusion imaging in the diagnosis of coronary artery disease (CAD). Methods: A total of 56 patients were divided into atropine-4 min adenosine stress (research group) and 6 min adenosine infusion (control group). The sex, age, the severity of CAD (judged by coronary, angiography) and associated symptoms were matched between the 2 groups. In research group, 0.5 mg atropine was injected intravenously 10 min before adenosine infusion. Adenosine was infused at a rate of 0.14 mg·kg -1 ·min -1 intravenously for 4 min and 6 min in research and control groups. At 3 min after adenosine infusion, 740 MBq 99 Tc m -MIBI was injected. SPECT myocardial imaging was obtained 1.5 h later. A rest myocardial perfusion imaging was performed on the following day. Results: (1) In research group and control group, the sensitivity, specificity, diagnostic accuracy was 85%, 6/8, 82% and 86%, 5/7, 82%, respectively (χ 2 0.05). (2)The sensitivity of the adenosine test for detection of single vessel, two vessels, three vessels disease were 6/7, 8/9, 3/4 and 7/8, 7/8, 4/5 in research group and control group, respectively(χ 2 0.05). (3) Side affects occurred in 82% of the patients in the research group and in 89% of the patients in the control group. The incidence of side effects in the two groups was not significantly different besides chest depression (43% and 68%, χ 2 =4.000, <0.05). Conclusions: Atropine-4 min adenosine infusion, in combination with perfusion tomography, has similar diagnostic efficacy for CAD to the 6 min protocol, and has lower incidence of chest depression than the standard 6 min infusion. (authors)

  10. Postural influence on intracranial and cerebral perfusion pressure in ambulatory neurosurgical patients

    DEFF Research Database (Denmark)

    Petersen, Lonnie Grove; Petersen, Johan Casper Grove; Andresen, Morten

    2016-01-01

    .4±4.2 mmHg when standing up (Phydrostatic pressure gradient with reference just below the heart, likely reflecting the venous hydrostatic...... indifference point. When upright, the decrease in ICP was attenuated, corresponding to formation of a separate hydrostatic gradient with reference to the base of the skull, likely reflecting the site of venous collapse. ICP therefore seems to be governed by pressure in the draining veins and collapse of neck......We evaluated postural effects on intracranial pressure (ICP) and cerebral perfusion pressure (CPP: mean arterial pressure (MAP) - ICP) in neurosurgical patients undergoing 24-hour ICP monitoring as part of their diagnostic workup. We identified 9 patients (5 women, age 44±20 yrs.; mean±SD) who were...

  11. Nuclear medicine and coronary artery disease: evaluation of tracers of myocardial perfusion and vulnerable atherosclerotic plaque; Medecine nucleaire et maladie coronarienne: evaluation de traceurs de la perfusion myocardique et de la plaque d'atherome vulnerable

    Energy Technology Data Exchange (ETDEWEB)

    Broisat, A

    2005-04-15

    Coronary artery disease is one of the primary cause of mortality worldwide. Nuclear medicine is the major imaging technique for diagnosis and following of this disease. perfusion: nowadays, major radioactive agents used in clinical practice are myocardial perfusion tracers. The reference tracer is thallium-201. However, {sup 201}Tl presents some drawbacks. {sup 99m}Tcn-noet has been proposed for its replacement. This study shows that in contrast with previous studies realized in vitro on cardio myocytes, verapamil, an l-type calcium channel inhibitor, does not inhibit myocardial fixation of {sup 99m}Tcn-noet in vivo in dog. This data is in agreement with the hypothesis of a non specific endothelial fixation of this tracer. Moreover, this study shows that as a pure tracer of myocardial perfusion, {sup 99m}Tcn-noet can also be used to assess myocardial viability on a model of myocardial chronic infarction in rat. atherosclerosis: disruption of vulnerable atherosclerotic plaques is the main event leading to coronary accidents. The second part of this study concerns the evaluation of new potential tracers of the vulnerable atherosclerotic plaque in an experimental model of rabbit with an inheritable hypercholesterolemia. The four tracers evaluated (b2702(r), b2702-I, b2702-Tc and Tc-raft-b2702) are synthetic peptides comprising the residues 75-84 of hla-b2702, a molecule known to link vcam-1, an adhesion molecule expressed in vulnerable atherosclerotic plaque. The autoradiography studies show that all tracers accumulate within atherosclerotic plaque expressing vcam- and that. i-b2702 shows the best plaque/control fixation ratio. (author)

  12. SPECT Myocardial Blood Flow Quantitation Concludes Equivocal Myocardial Perfusion SPECT Studies to Increase Diagnostic Benefits.

    Science.gov (United States)

    Chen, Lung-Ching; Lin, Chih-Yuan; Chen, Ing-Jou; Ku, Chi-Tai; Chen, Yen-Kung; Hsu, Bailing

    2016-01-01

    Recently, myocardial blood flow quantitation with dynamic SPECT/CT has been reported to enhance the detection of coronary artery disease in human. This advance has created important clinical applications to coronary artery disease diagnosis and management for areas where myocardial perfusion PET tracers are not available. We present 2 clinical cases that undergone a combined test of 1-day rest/dipyridamole-stress dynamic SPECT and ECG-gated myocardial perfusion SPECT scans using an integrated imaging protocol and demonstrate that flow parameters are capable to conclude equivocal myocardial perfusion SPECT studies, therefore increasing diagnostic benefits to add value in making clinical decisions.

  13. Validation of a model of left ventricular segmentation for interpretation of SPET myocardial perfusion images

    Energy Technology Data Exchange (ETDEWEB)

    Aepfelbacher, F.C.; Johnson, R.B.; Schwartz, J.G.; Danias, P.G. [Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA (United States); Chen, L.; Parker, R.A. [Biometrics Center, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA (United States); Parker, A.J. [Nuclear Medicine Division, Department of Radiology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA (United States)

    2001-11-01

    Several models of left ventricular segmentation have been developed that assume a standard coronary artery distribution, and are currently used for interpretation of single-photon emission tomography (SPET) myocardial perfusion imaging. This approach has the potential for incorrect assignment of myocardial segments to vascular territories, possibly over- or underestimating the number of vessels with significant coronary artery disease (CAD). We therefore sought to validate a 17-segment model of myocardial perfusion by comparing the predefined coronary territory assignment with the actual angiographically derived coronary distribution. We examined 135 patients who underwent both coronary angiography and stress SPET imaging within 30 days. Individualized coronary distribution was determined by review of the coronary angiograms and used to identify the coronary artery supplying each of the 17 myocardial segments of the model. The actual coronary distribution was used to assess the accuracy of the assumed coronary distribution of the model. The sensitivities and specificities of stress SPET for detection of CAD in individual coronary arteries and the classification regarding perceived number of diseased coronary arteries were also compared between the two coronary distributions (actual and assumed). The assumed coronary distribution corresponded to the actual coronary anatomy in all but one segment (3). The majority of patients (80%) had 14 or more concordant segments. Sensitivities and specificities of stress SPET for detection of CAD in the coronary territories were similar, with the exception of the RCA territory, for which specificity for detection of CAD was better for the angiographically derived coronary artery distribution than for the model. There was 95% agreement between assumed and angiographically derived coronary distributions in classification to single- versus multi-vessel CAD. Reassignment of a single segment (segment 3) from the LCX to the LAD

  14. Validation of a model of left ventricular segmentation for interpretation of SPET myocardial perfusion images

    International Nuclear Information System (INIS)

    Aepfelbacher, F.C.; Johnson, R.B.; Schwartz, J.G.; Danias, P.G.; Chen, L.; Parker, R.A.; Parker, A.J.

    2001-01-01

    Several models of left ventricular segmentation have been developed that assume a standard coronary artery distribution, and are currently used for interpretation of single-photon emission tomography (SPET) myocardial perfusion imaging. This approach has the potential for incorrect assignment of myocardial segments to vascular territories, possibly over- or underestimating the number of vessels with significant coronary artery disease (CAD). We therefore sought to validate a 17-segment model of myocardial perfusion by comparing the predefined coronary territory assignment with the actual angiographically derived coronary distribution. We examined 135 patients who underwent both coronary angiography and stress SPET imaging within 30 days. Individualized coronary distribution was determined by review of the coronary angiograms and used to identify the coronary artery supplying each of the 17 myocardial segments of the model. The actual coronary distribution was used to assess the accuracy of the assumed coronary distribution of the model. The sensitivities and specificities of stress SPET for detection of CAD in individual coronary arteries and the classification regarding perceived number of diseased coronary arteries were also compared between the two coronary distributions (actual and assumed). The assumed coronary distribution corresponded to the actual coronary anatomy in all but one segment (3). The majority of patients (80%) had 14 or more concordant segments. Sensitivities and specificities of stress SPET for detection of CAD in the coronary territories were similar, with the exception of the RCA territory, for which specificity for detection of CAD was better for the angiographically derived coronary artery distribution than for the model. There was 95% agreement between assumed and angiographically derived coronary distributions in classification to single- versus multi-vessel CAD. Reassignment of a single segment (segment 3) from the LCX to the LAD

  15. Long-term cigarette smoking is associated with increased myocardial perfusion heterogeneity assessed by positron emission tomography

    International Nuclear Information System (INIS)

    Meeder, J.G.; Blanksma, P.K.; Wall, E.E. van der; Anthonio, R.L.; Willemsen, A.T.M.; Pruim, J.; Vaalburg, W.; Lie, K.I.

    1996-01-01

    The pathophysiology of smoking-related coronary events in patients with normal coronary arteries is incompletely understood. This study was conducted to explore, in subjects without symptoms of cardiovascular disease, the long-term effects of smoking on regional coronary artery vasoactivity, especially during sympathetic stimulation. In ten smoking and ten non-smoking sex- and age-matched healthy volunteers, segmental myocardial perfusion was studied using dynamic parametric nitrogen-13 ammonia positron emission tomography at rest and during sympathetic stimulation evoked by the cold pressor stimulation. Smokers demonstrated a higher myocardial perfusion at rest (116±17 ml/min/100 g vs 96±20 ml/min/100 g, P <0.01) and an impaired myocardial perfusion increase during cold pressor stimulation (1.02±0.15 vs 1.18±0.17, P <0.05). The heterogeneity of perfusion, expressed as coefficient of variation, was significantly different between the smoking and the non-smoking group. The coefficient of variation of segmental myocardial perfusion was higher in smokers at rest (17.5%±4.2% vs 13.5%±1.9%, P <0.05) and during cold pressor stimulation (17.0%±3.2% vs 13.9%±1.8%, P <0.05). We conclude that the long-term effects of smoking in healthy volunteers are associated with (1) increased myocardial perfusion at rest, (2) impaired myocardial perfusion response to cold pressor stimulation, and (3) increased myocardial perfusion heterogeneity both at rest and during cold pressor stimulation. These results may suggest that in healthy subjects the long-term effect of smoking is related to abnormal coronary artery vasoactivity, presumably induced by an interplay of regional endothelial dysfunction and autonomic dysregulation. (orig.). With 1 fig., 1 tab

  16. Use of myocardial perfusion imaging to predict the effectiveness of coronary revascularisation in patients with stable angina pectoris

    International Nuclear Information System (INIS)

    Johansen, Allan; Hoeilund-Carlsen, Poul Flemming; Moeldrup, Mette; Christensen, Henrik Wulff; Vach, Werner; Haghfelt, Torben

    2005-01-01

    Coronary revascularisation is the treatment of choice in patients with stable angina who have significant stenoses. From a pathophysiological point of view, however, mitigation of angina is to be expected only in the presence of reversible ischaemia. Therefore it was the aim of this study to examine the effect of revascularisation on stable angina in relation to the myocardial perfusion imaging (MPI) pattern prior to intervention. Three hundred and eighty-four patients (58.0±8.8 years) referred for angiography underwent MPI. Prior to MPI and at 2-year follow-up, patients were classified as having typical angina, atypical angina, non-cardiac chest pain or no pain, and the severity of chest pain was graded according to the Canadian Cardiovascular Society (CCS) criteria. The patients themselves estimated their pain on a visual analogue scale. Management was based on symptoms and angiographic findings, since the results of MPI were not communicated. Among the 240 patients who were not revascularised, 79% had typical or atypical angina at study entrance versus 40% at follow-up. In comparison, 93% of the 144 revascularised patients had typical or atypical angina before intervention versus only 36% at follow-up. This additional advantage of invasive therapy was present only in patients with reversible defects; revascularisation had no additional effect in patients with normal perfusion or irreversible defects. Similarly, additional, significant reductions in CCS class and visual analogue score were observed exclusively in patients with reversible defects. In patients referred for coronary angiography owing to known or suspected stable angina, revascularisation was significantly more effective than medical treatment exclusively in patients with reversible ischaemia. (orig.)

  17. Very high coronary artery calcium score with normal myocardial perfusion SPECT imaging is associated with a moderate incidence of severe coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Yuoness, Salem A.; Goha, Ahmed M.; Romsa, Jonathan G.; Akincioglu, Cigdem; Warrington, James C.; Datta, Sudip; Gambhir, Sanjay; Urbain, Jean-Luc C.; Vezina, William C. [London Health Sciences Centre, Department of Nuclear Medicine, London, ON (Canada); Massel, David R. [London Health Sciences Centre, Division of Cardiology, London, ON (Canada); Martell, Rafael [Private Practice, London, ON (Canada)

    2015-09-15

    Myocardial perfusion imaging (MPI) has limitations in the presence of balanced multivessel disease (MVD) and left main (LM) coronary artery disease, occasionally resulting in false-normal results despite the high cardiovascular risk associated with this condition. The purpose of this study was to assess the incidence of severe coronary artery disease (CAD) in the presence of a very high Agatston coronary artery calcium (CAC) score (>1,000) in stable symptomatic patients without known CAD but with normal MPI results. A total of 2,659 prospectively acquired consecutive patients were referred for MPI and evaluation of CAC score by CT. Of this patient population, 8 % (222/2,659) had ischemia without myocardial infarction (MI) on MPI and 11 % (298/2,659) had abnormal MPI (MI and/or ischemia). On presentation 1 % of the patients (26/2,659) were symptomatic, had a CAC score >1,000 and normal MPI results. The definition of normal MPI was strict and included a normal hemodynamic response without ischemic ECG changes and normal imaging, particularly absence of transient ischemic dilation. All of these 26 patients with a CAC score >1,000 and normal MPI findings underwent cardiac catheterization. Of these 26 patients, 58 % (15/26) had severe disease (≥70 % stenosis) leading to revascularization. Of this group, 47 % (7/15) underwent percutaneous intervention, and 53 % (8/15) underwent coronary artery bypass grafting. All of these 15 patients had either MVD (14/15) or LM coronary artery disease (1/15), and represented 0.6 % (15/2,659) of all referred patients (95 % CI 0.3 - 0.9 %). The majority, 90 % (8/9), had severe CAD with typical chest pain. A very high CAC score (>1,000) with normal MPI in a small subset of symptomatically stable patients was associated with a moderate incidence of severe CAD (95 % CI 37 - 77 %). Larger studies and/or a meta-analysis of small studies are needed to more precisely estimate the incidence of CAD in this population. This study also supports

  18. Differential uptake of FDG and DG during post-ischaemic reperfusion in the isolated, perfused rat heart

    Energy Technology Data Exchange (ETDEWEB)

    Garlick, P.B.; Medina, R.A.; Southworth, R.; Marsden, P.K. [Department of Radiological Sciences, Guy' s, King' s and St. Thomas' School of Medicine, London (United Kingdom)

    1999-10-01

    Fluorine-18 2-fluoro-2-deoxyglucose (FDG) and 2-deoxyglucose (DG) are widely used as tracers of glucose uptake in the myocardium. Although there is agreement that the two analogues behave similarly to glucose under control conditions, there is growing evidence that some interventions (e.g. insulin stimulation or ischaemia/reperfusion) cause differential changes in their behaviour. The addition of a two-surface coil nuclear magnetic resonance (NMR) probe and a dual-perfusion cannula to our recently developed PET and NMR dual-acquisition (PANDA) system allows us to collect PET (FDG) images and phosphorus-31 NMR (2-deoxyglucose-6-phosphate) spectra simultaneously from each independently perfused coronary bed of the heart. We have used this technique to study the effect of regional ischaemia/reperfusion on FDG and DG uptake in the isolated, perfused rat heart. During control perfusion, FDG uptake was almost identical in both coronary beds. When one coronary bed was made ischaemic, FDG uptake ceased on that side but continued on the control side. Reperfusion failed to restore FDG uptake. In contrast, NMR spectra showed that, during reperfusion, the uptake and phosphorylation of DG did not differ between the two coronary beds. The results thus demonstrate that regional myocardial ischaemia/reperfusion has different effects on the uptake of FDG and DG in the isolated, perfused rat heart. (orig.)

  19. Differential uptake of FDG and DG during post-ischaemic reperfusion in the isolated, perfused rat heart

    International Nuclear Information System (INIS)

    Garlick, P.B.; Medina, R.A.; Southworth, R.; Marsden, P.K.

    1999-01-01

    Fluorine-18 2-fluoro-2-deoxyglucose (FDG) and 2-deoxyglucose (DG) are widely used as tracers of glucose uptake in the myocardium. Although there is agreement that the two analogues behave similarly to glucose under control conditions, there is growing evidence that some interventions (e.g. insulin stimulation or ischaemia/reperfusion) cause differential changes in their behaviour. The addition of a two-surface coil nuclear magnetic resonance (NMR) probe and a dual-perfusion cannula to our recently developed PET and NMR dual-acquisition (PANDA) system allows us to collect PET (FDG) images and phosphorus-31 NMR (2-deoxyglucose-6-phosphate) spectra simultaneously from each independently perfused coronary bed of the heart. We have used this technique to study the effect of regional ischaemia/reperfusion on FDG and DG uptake in the isolated, perfused rat heart. During control perfusion, FDG uptake was almost identical in both coronary beds. When one coronary bed was made ischaemic, FDG uptake ceased on that side but continued on the control side. Reperfusion failed to restore FDG uptake. In contrast, NMR spectra showed that, during reperfusion, the uptake and phosphorylation of DG did not differ between the two coronary beds. The results thus demonstrate that regional myocardial ischaemia/reperfusion has different effects on the uptake of FDG and DG in the isolated, perfused rat heart. (orig.)

  20. Integration of a capacitive pressure sensing system into the outer catheter wall for coronary artery FFR measurements

    Science.gov (United States)

    Stam, Frank; Kuisma, Heikki; Gao, Feng; Saarilahti, Jaakko; Gomes Martins, David; Kärkkäinen, Anu; Marrinan, Brendan; Pintal, Sebastian

    2017-05-01

    The deadliest disease in the world is coronary artery disease (CAD), which is related to a narrowing (stenosis) of blood vessels due to fatty deposits, plaque, on the arterial walls. The level of stenosis in the coronary arteries can be assessed by Fractional Flow Reserve (FFR) measurements. This involves determining the ratio between the maximum achievable blood flow in a diseased coronary artery and the theoretical maximum flow in a normal coronary artery. The blood flow is represented by a pressure drop, thus a pressure wire or pressure sensor integrated in a catheter can be used to calculate the ratio between the coronary pressure distal to the stenosis and the normal coronary pressure. A 2 Fr (0.67mm) outer diameter catheter was used, which required a high level of microelectronics miniaturisation to fit a pressure sensing system into the outer wall. The catheter has an eccentric guidewire lumen with a diameter of 0.43mm, which implies that the thickest catheter wall section provides less than 210 microns height for flex assembly integration consisting of two dies, a capacitive MEMS pressure sensor and an ASIC. In order to achieve this a very thin circuit flex was used, and the two chips were thinned down to 75 microns and flip chip mounted face down on the flex. Many challenges were involved in obtaining a flex layout that could wrap into a small tube without getting the dies damaged, while still maintaining enough flexibility for the catheter to navigate the arterial system.

  1. The role of pharmacological stress Tc-99m sestamibi myocardial perfusion imaging in an Australian population

    International Nuclear Information System (INIS)

    Howarth, D.M.; Booker, J.A.; Tan, T.S.K.; Bellamy, G.R.; Hardy, D.B.; Howarth, G.C.

    2003-01-01

    This observational study was performed in order to assess the exercise-related incremental diagnostic accuracy of Tc-99m sestamibi myocardial perfusion imaging (MPI) in a hospital-based Australian population, and to assess the relative roles of exercise and pharmacological stress in myocardial perfusion imaging (MPI). Two hundred and eight adult patients who had both Tc-99m sestamibi myocardial perfusion imaging and coronary angiography within a median time of 16 weeks were studied. The diagnostic end-point was coronary artery lesions of ≥50% and >70% stenosis detected on angiography. Using receiver operating characteristic curve analysis, the overall diagnostic accuracy was calculated, as well as the comparative accuracies in patients who undertook various levels of exercise stress testing (n=130) and those who received pharmacological (dipyridamole) stress testing (n=78). The overall respective diagnostic accuracy of Tc-99m sestamibi MPI for the diagnosis of coronary artery disease (>70% stenosis) was 81% and 76% when using the diagnostic criterion of ≥50% stenosis. On direct comparison of perfusion defects with angiographic stenoses, the respective sensitivity and specificity for the detection of >70% stenosis in each coronary artery territory was 73% and 79%. Pharmacological MPI showed a significantly greater sensitivity for the detection of localised stenoses compared to the overall group who had exercise MPI performed. Consequently, exercise stress MPI showed significantly more false negative lesions compared to dipyridamole stress imaging (p<0.003). However, a large proportion of patients were unable to perform to adequate exercise levels in this patient sample. We conclude that Tc-99m sestamibi myocardial perfusion imaging is an accurate non-invasive test for the diagnosis of coronary artery disease. Where any doubt exists as to the patient's ability to achieve exercise levels at or above 85% of the predicted value for age and gender, pharmacological

  2. Subendocardial versus transmural ischaemia in myocardial perfusion SPECT--a Monte Carlo study

    DEFF Research Database (Denmark)

    Bartosik, Jolanta; El-Ali, Henrik Hussein; Nilsson, Ulf

    2006-01-01

    Myocardial perfusion imaging with single-photon emission computed tomography (SPECT) is useful for the evaluation of patients with known or suspected coronary artery disease. Parameters of interest are the reduction in the blood perfusion (severity) and the lesion volume (extent). The aim of this...

  3. Myocardial perfusion scintigraphy with thallium-201 - principle and method

    International Nuclear Information System (INIS)

    Dressler, J.

    1981-01-01

    Since from the cardiological and cardio-surgical aspects non-invasive methods practicable in the diagnostics of regional myocardial blood perfusion are claiming priority, the myocardial perfusion scintigraphy with thallium 201 has gained more and more importance in the diagnostics of coronary heart diseases. Although radiothallium because of its nucleo-physical characteristics is not regarded as ideal radiopharmaceutical, it is at present, because of its potassium-analogue biokinetics the best radiopharmaceutical to represent the regional coronary perfusion distribution, the vitality and configuration of the heart muscle non-invasively. With careful clinical indication and under consideration of the physico-technical limitations, the informative value provided by the serial scintigraphy with thallium 201 is greater than that provided by the excercise ECG. Various possibilities for solving the problem of quantitative analysis of the myocardial scintigrams have been given. Up to the present day a standardised evaluation procedure corresponding to that of the visual scintigram interpretation has not yet found general acceptance. (orig.) [de

  4. The dream of a one-stop-shop : Meta-analysis on myocardial perfusion CT

    NARCIS (Netherlands)

    Pelgrim, Gert Jan; Dorrius, Monique; Xie, Xueqian; den Dekker, Martijn A. M.; Schoepf, U. Joseph; Henzler, Thomas; Oudkerk, Matthijs; Vliegenthart, Rozemarijn

    2015-01-01

    Purpose: To determine the diagnostic performance of computed tomography (CT) perfusion techniques for the detection of functionally relevant coronary artery disease (CAD) in comparison to reference standards, including invasive coronary angiography (ICA), single photon emission computed tomography

  5. Dipyridamole-induced ST segment depression during thallium-201 imaging in patients with coronary artery disease: angiographic and hemodynamic determinants

    International Nuclear Information System (INIS)

    Chambers, C.E.; Brown, K.A.

    1988-01-01

    To examine the angiographic and hemodynamic determinants of dipyridamole-induced ST segment depression in patients with coronary artery disease, 41 patients with angiographically documented coronary disease who underwent dipyridamole-thallium-201 myocardial scintigraphy were studied. Dipyridamole-induced ST depression occurred in 14 (34%) of the 41 patients. Stepwise multivariate logistic regression was performed to compare the predictive value of angiographic findings (good coronary collateral vessels, jeopardized collateral vessels, multivessel disease), hemodynamic changes (changes in heart rate, systolic pressure, diastolic pressure and rate-pressure product), thallium-201 results (perfusion defect, thallium-201 redistribution) and demographic data (age, gender, medications). Only the presence of good coronary collateral vessels (p less than 0.02) and increases in rate-pressure product after dipyridamole infusion (p less than 0.02) were significant multivariate predictors of dipyridamole-induced ST depression. Good collateral vessels were more common in the group with ST depression (11 [79%] of 14) than they were in the group without ST depression (6 [22%] of 27; p less than 0.001). Rate-pressure product increased 2,835 +/- 1,648 beats/min.mm Hg in the group with ST depression compared with 1,179 +/- 1,417 beats/min.mm Hg in patients without ST depression (p less than 0.005). In conclusion, dipyridamole-induced ST segment depression in patients with coronary artery disease appears to be related to 1) the presence of good coronary collateral vessels, which may act by facilitating coronary steal, and 2) increases in rate-pressure product, reflecting increased myocardial oxygen demand. These observations may explain the lack of prognostic value of dipyridamole-induced ST segment depression described in previous reports

  6. Diagnostic accuracy of static CT perfusion for the detection of myocardial ischemia

    DEFF Research Database (Denmark)

    Sørgaard, Mathias Holm; Kofoed, Klaus Fuglsang; Linde, Jesper James

    2016-01-01

    : Systematic literature review and meta-analysis of studies examining the diagnostic accuracy of static CTP imaging alone or combined with coronary CT angiography (CTA) in comparison to single photon emission computed tomography (SPECT), magnetic resonance perfusion (MRP), and/or invasive coronary angiography...

  7. Stenosis differentially affects subendocardial and subepicardial arterioles in vivo

    NARCIS (Netherlands)

    Merkus, D.; Vergroesen, I.; Hiramatsu, O.; Tachibana, H.; Nakamoto, H.; Toyota, E.; Goto, M.; Ogasawara, Y.; Spaan, J. A.; Kajiya, F.

    2001-01-01

    The presence of a coronary stenosis results primarily in subendocardial ischemia. Apart from the decrease in coronary perfusion pressure, a stenosis also decreases coronary flow pulsations. Applying a coronary perfusion system, we compared the autoregulatory response of subendocardial (n = 10) and

  8. Comparing CT perfusion with oxygen partial pressure in a rabbit VX2 soft-tissue tumor model

    International Nuclear Information System (INIS)

    Sun Changjin; Li Chao; Lv Haibo

    2014-01-01

    The aim of this study was to evaluate the oxygen partial pressure of the rabbit model of the VX2 tumor using a 64-slice perfusion CT and to compare the results with that obtained using the oxygen microelectrode method. Perfusion CT was performed for 45 successfully constructed rabbit models of a VX2 brain tumor. The perfusion values of the brain tumor region of interest, the blood volume (BV), the time to peak (TTP) and the peak enhancement intensity (PEI) were measured. The results were compared with the partial pressure of oxygen (PO2) of that region of interest obtained using the oxygen microelectrode method. The perfusion values of the brain tumor region of interest in 45 successfully constructed rabbit models of a VX2 brain tumor ranged from 1.3–127.0 (average, 21.1 ± 26.7 ml/min/ml); BV ranged from 1.2–53.5 ml/100g (average, 22.2 ± 13.7 ml/100g); PEI ranged from 8.7–124.6 HU (average, 43.5 ± 28.7 HU); and TTP ranged from 8.2–62.3 s (average, 38.8 ± 14.8 s). The PO2 in the corresponding region ranged from 0.14–47 mmHg (average, 16 ± 14.8 mmHg). The perfusion CT positively correlated with the tumor PO2, which can be used for evaluating the tumor hypoxia in clinical practice. (author)

  9. Comparing CT perfusion with oxygen partial pressure in a rabbit VX2 soft-tissue tumor model.

    Science.gov (United States)

    Sun, Chang-Jin; Li, Chao; Lv, Hai-Bo; Zhao, Cong; Yu, Jin-Ming; Wang, Guang-Hui; Luo, Yun-Xiu; Li, Yan; Xiao, Mingyong; Yin, Jun; Lang, Jin-Yi

    2014-01-01

    The aim of this study was to evaluate the oxygen partial pressure of the rabbit model of the VX2 tumor using a 64-slice perfusion CT and to compare the results with that obtained using the oxygen microelectrode method. Perfusion CT was performed for 45 successfully constructed rabbit models of a VX2 brain tumor. The perfusion values of the brain tumor region of interest, the blood volume (BV), the time to peak (TTP) and the peak enhancement intensity (PEI) were measured. The results were compared with the partial pressure of oxygen (PO2) of that region of interest obtained using the oxygen microelectrode method. The perfusion values of the brain tumor region of interest in 45 successfully constructed rabbit models of a VX2 brain tumor ranged from 1.3-127.0 (average, 21.1 ± 26.7 ml/min/ml); BV ranged from 1.2-53.5 ml/100g (average, 22.2 ± 13.7 ml/100g); PEI ranged from 8.7-124.6 HU (average, 43.5 ± 28.7 HU); and TTP ranged from 8.2-62.3 s (average, 38.8 ± 14.8 s). The PO2 in the corresponding region ranged from 0.14-47 mmHg (average, 16 ± 14.8 mmHg). The perfusion CT positively correlated with the tumor PO2, which can be used for evaluating the tumor hypoxia in clinical practice.

  10. Successful transcatheter closure of coronary artery fistula in a child with single coronary artery: a heavy load and a long road.

    Science.gov (United States)

    Phasalkar, Manjunath; Thakkar, Bhavesh; Poptani, Vishal

    2013-07-01

    Single coronary artery is an uncommon variation of the coronary circulation. After transposition of great arteries, coronary artery fistulas are the most common associated cardiac anomalies in these patients. Transcatheter closure of coronary artery fistula (CAF) involving single coronary artery is a challenging intervention. In the absence of contralateral coronary artery, a complex anatomy of the CAF and a large myocardial perfusion territory of the dominant circulation pose an additional risk during interventional procedure. We report our experience of a successful transcatheter closure of a coronary artery fistula in a patient with single coronary artery. Copyright © 2013 Wiley Periodicals, Inc.

  11. PLACENTAL GROWTH FACTOR AND CORONARY NEOANGIOGENESIS IN CORONARY HEART DISEASE

    Directory of Open Access Journals (Sweden)

    M. V. Tulikov

    2013-01-01

    Full Text Available Neoangiogenesis in coronary heart disease is a protective reaction aimed to improve ischemic myocardial perfusion, by increasing the number and size of arterial collaterals. Placental growth factor (PlGF is one of the key peptides regulating angiogenic processes in atherosclerosis. In particular, a number of investigators have shown that injection of recombinant PlGF into the system or regional blood flow can stimulate neoangiogenesis. On the other hand, there is evidence confirming the involvement of PlGF in the progression of atherosclerosis and in the development of acute coronary syndrome. In this connection, the problem of investigating the efficiency and safety of possible use of PlGF preparations, as well as its place in the diagnosis of coronary heart disease and acute coronary syndrome remains urgent

  12. Nuclear medicine and coronary artery disease: evaluation of tracers of myocardial perfusion and vulnerable atherosclerotic plaque; Medecine nucleaire et maladie coronarienne: evaluation de traceurs de la perfusion myocardique et de la plaque d'atherome vulnerable

    Energy Technology Data Exchange (ETDEWEB)

    Broisat, A

    2005-04-15

    Coronary artery disease is one of the primary cause of mortality worldwide. Nuclear medicine is the major imaging technique for diagnosis and following of this disease. perfusion: nowadays, major radioactive agents used in clinical practice are myocardial perfusion tracers. The reference tracer is thallium-201. However, {sup 201}Tl presents some drawbacks. {sup 99m}Tcn-noet has been proposed for its replacement. This study shows that in contrast with previous studies realized in vitro on cardio myocytes, verapamil, an l-type calcium channel inhibitor, does not inhibit myocardial fixation of {sup 99m}Tcn-noet in vivo in dog. This data is in agreement with the hypothesis of a non specific endothelial fixation of this tracer. Moreover, this study shows that as a pure tracer of myocardial perfusion, {sup 99m}Tcn-noet can also be used to assess myocardial viability on a model of myocardial chronic infarction in rat. atherosclerosis: disruption of vulnerable atherosclerotic plaques is the main event leading to coronary accidents. The second part of this study concerns the evaluation of new potential tracers of the vulnerable atherosclerotic plaque in an experimental model of rabbit with an inheritable hypercholesterolemia. The four tracers evaluated (b2702(r), b2702-I, b2702-Tc and Tc-raft-b2702) are synthetic peptides comprising the residues 75-84 of hla-b2702, a molecule known to link vcam-1, an adhesion molecule expressed in vulnerable atherosclerotic plaque. The autoradiography studies show that all tracers accumulate within atherosclerotic plaque expressing vcam- and that. i-b2702 shows the best plaque/control fixation ratio. (author)

  13. Relationship between inter-arm blood pressure difference and severity of coronary atherosclerosis.

    Science.gov (United States)

    Park, Se-Jun; Son, Jung-Woo; Park, Sang-Min; Choi, Hyun-Hee; Hong, Kyung-Soon

    2017-08-01

    A greater inter-arm blood pressure difference (IABPD) is associated with atherosclerosis, but its association with coronary artery disease is unknown. We investigated the relationship between IABPD and coronary atherosclerosis. We retrospectively reviewed blood pressure (BP) data that was measured simultaneously in both arms of patients who underwent initial coronary angiography. Coronary atherosclerosis was assessed using the Gensini score, based on quantitative coronary angiography findings. To adjust for the effect of baseline BP, the percentages of systolic IABPD to higher mean BP (cIABPD sys ), diastolic IABPD to higher mean BP (cIABPD dia ), and mean IABPD to higher mean BP (cIABPD mean ) were calculated as BP-adjusted IABPDs. We examined the records of 816 patients (516 males, mean age: 65.5 ± 11.8 years). The mean Gensini score was 33.4 ± 30.4, and the median was 25. All cIAPBDs had positive correlations with the Gensini score (cIABPD sys : r = 0.208, p < 0.001; cIABPD dia : r = 0.123, p < 0.001; cIABPD mean : r = 0.120, p = 0.001). Multiple regression analysis indicated that cIABPD sys was associated with the Gensini score, independently of age, gender, smoking, diabetes, hypertension and dyslipidemia (B = 0.031, p < 0.001). The BP-adjusted IABPD parameters are related to the severity of coronary artery disease. Further studies should investigate the use of the IABPD to improve management of coronary atherosclerosis. Copyright © 2017. Published by Elsevier B.V.

  14. Prevalence of asymptomatic coronary disease in fibrosing idiopathic interstitial pneumonias

    International Nuclear Information System (INIS)

    Cassagnes, Lucie; Gaillard, Vianney; Monge, Emmanuel; Faivre, Jean-Baptiste; Delhaye, Cédric; Molinari, Francesco; Petyt, Grégory; Hossein-Foucher, Claude; Wallaert, Benoit; Duhamel, Alain; Remy, Jacques; Remy-Jardin, Martine

    2015-01-01

    Background: Because of growing body of interest on the association between fibrosing idiopathic interstitial pneumonias (f-IIP) and ischaemic heart disease, we initiated this prospective study to evaluate the prevalence of asymptomatic coronary artery disease (CAD) in patients with f-IIP. Methods: Forty-two patients with f-IIP underwent noninvasive screening for CAD that included (a) a chest CT examination enabling calculation of the coronary artery calcium (CAC) score, then depiction of coronary artery stenosis; and (b) stress myocardial perfusion scintigraphy (MPS). Patients with significant coronary abnormalities, defined by a CAC score >400 or coronary artery stenosis >50% at CT and/or perfusion defect >5% at MPS, were referred to the cardiologist. Coronary angiography was indicated in presence of a perfusion defect >10% at MPS or significant left main or proximal left anterior descending stenosis whatever MPS findings. Results: Combining CT and MPS, significant abnormalities were detected in 32/42 patients (76%). The cardiologist: (a) did not consider further investigation in 21 patients (CT abnormalities but no ischaemia at MPS: 12/21; false-positive findings at MPS: 3/21; poor respiratory condition: 6/21); (b) proceeded to coronary angiography in 11 patients which confirmed significant stenoses in 5 patients (5/42; 12%). In the worst-case-scenario (i.e., inclusion of 6 patients with significant coronary artery abnormalities who were not investigated due to poor respiratory condition), the prevalence of CAD reached 26% (11/42). Conclusion: In the studied population of patients with f-IIP, asymptomatic CAD ranged between 12% and 26%

  15. Prevalence of asymptomatic coronary disease in fibrosing idiopathic interstitial pneumonias

    Energy Technology Data Exchange (ETDEWEB)

    Cassagnes, Lucie; Gaillard, Vianney [Department of Thoracic Imaging (EA 2694), Hospital Calmette, CHRU and Univ Lille 2 Nord de France, F-59000 Lille (France); Monge, Emmanuel [Department of Pulmonology, Center of Competence for Rare Pulmonary Diseases, Hospital Calmette, CHRU and Univ Lille 2 Nord de France, F-59000 Lille (France); Faivre, Jean-Baptiste [Department of Thoracic Imaging (EA 2694), Hospital Calmette, CHRU and Univ Lille 2 Nord de France, F-59000 Lille (France); Delhaye, Cédric [Department of Cardiology, Cardiology Hospital, CHRU and Univ Lille 2 Nord de France, F-59000 Lille (France); Molinari, Francesco [Department of Thoracic Imaging (EA 2694), Hospital Calmette, CHRU and Univ Lille 2 Nord de France, F-59000 Lille (France); Petyt, Grégory; Hossein-Foucher, Claude [Department of Nuclear Medicine, Hospital Salengro, CHRU and Univ Lille 2 Nord de France, F-59000 Lille (France); Wallaert, Benoit [Department of Pulmonology, Center of Competence for Rare Pulmonary Diseases, Hospital Calmette, CHRU and Univ Lille 2 Nord de France, F-59000 Lille (France); Duhamel, Alain [Department of Medical Statistics (EA 2694), Univ Lille Nord de France, F-59000 Lille (France); Remy, Jacques [Department of Thoracic Imaging (EA 2694), Hospital Calmette, CHRU and Univ Lille 2 Nord de France, F-59000 Lille (France); Remy-Jardin, Martine, E-mail: martine.remy@chru-lille.fr [Department of Thoracic Imaging (EA 2694), Hospital Calmette, CHRU and Univ Lille 2 Nord de France, F-59000 Lille (France)

    2015-01-15

    Background: Because of growing body of interest on the association between fibrosing idiopathic interstitial pneumonias (f-IIP) and ischaemic heart disease, we initiated this prospective study to evaluate the prevalence of asymptomatic coronary artery disease (CAD) in patients with f-IIP. Methods: Forty-two patients with f-IIP underwent noninvasive screening for CAD that included (a) a chest CT examination enabling calculation of the coronary artery calcium (CAC) score, then depiction of coronary artery stenosis; and (b) stress myocardial perfusion scintigraphy (MPS). Patients with significant coronary abnormalities, defined by a CAC score >400 or coronary artery stenosis >50% at CT and/or perfusion defect >5% at MPS, were referred to the cardiologist. Coronary angiography was indicated in presence of a perfusion defect >10% at MPS or significant left main or proximal left anterior descending stenosis whatever MPS findings. Results: Combining CT and MPS, significant abnormalities were detected in 32/42 patients (76%). The cardiologist: (a) did not consider further investigation in 21 patients (CT abnormalities but no ischaemia at MPS: 12/21; false-positive findings at MPS: 3/21; poor respiratory condition: 6/21); (b) proceeded to coronary angiography in 11 patients which confirmed significant stenoses in 5 patients (5/42; 12%). In the worst-case-scenario (i.e., inclusion of 6 patients with significant coronary artery abnormalities who were not investigated due to poor respiratory condition), the prevalence of CAD reached 26% (11/42). Conclusion: In the studied population of patients with f-IIP, asymptomatic CAD ranged between 12% and 26%.

  16. Exercise thallium-201 myocardial imaging in left main coronary artery disease: sensitive but not specific

    International Nuclear Information System (INIS)

    Rehn, T.; Griffith, L.S.; Achuff, S.C.; Bailey, I.K.; Bulkley, B.H.; Burow, R.; Pitt, B.; Becker, L.C.

    1981-01-01

    To determine the usefulness of thallium-201 scintigraphy for identifying left main coronary artery disease, the results of scintigraphy at rest and during exercise were compared in 24 patients with 50 percent or greater narrowing of the left main coronary artery and 80 patients with 50 percent or greater narrowing of one or more of the major coronary arteries but without left main coronary involvement. By segmental analysis of the scintigrams, perfusion defects were assigned to the left anterior descending, left circumflex or right coronary artery, singly or in combination, and the pattern of simultaneous left anterior descending and circumflex arterial defects was used to identify left main coronary artery disease. Of the 24 patients with left main coronary artery disease, 22 (92 percent) had abnormal exercise scintigrams. Despite this high sensitivity, the pattern of perfusion defects was not specific; the ''left main pattern'' was found in 3 patients (13 percent) with left main coronary artery disease but also in 3 (33 percent) of 9 patients with combined left anterior descending and left circumflex arterial disease, 4 (19 percent) of 21 patients with three vessel disease and 3 (6 percent) of 50 patients with one or two vessel disease but excluding the group with left anterior descending plus left circumflex arterial disease. The pattern of perfusion defects in the patients with left main coronary artery disease was determined by the location and severity of narrowings in the coronary arteries downstream from the left main arterial lesion. Concomitant lesions in other arteries were found in all patients with left main coronary disease (one vessel in 1 patient, two vessels in 7 patients and three vessels in 16). For this reason, it is unlikely that even with improvements in radiopharmaceutical agents and imaging techniques, myocardial perfusion scintigraphy will be sufficiently specific for definitive identification of left main coronary artery disease

  17. Decreased perfusion in myocardial region of normal donor artery secondary to collateral development

    International Nuclear Information System (INIS)

    Koga, Y.; Takahashi, M.; Kojima, A.; Takaki, Y.; Tomiguchi, S.; Hirota, Y.; Kugiyama, K.; Yasue, H.; Hayasaki, K.; Kumamoto Saiseikai Hospital

    1992-01-01

    Thirty-one patients suffering from single vessel exertional angina with collaterals (Group A) were evaluated by stress 201 Tl myocardial emission CT (Tl-SPECT) with 16 controls of severely stenotic single vessel exertional angina without collaterals (Group B). Group A included 21 patients (68%) who showed an extensive perfusion defect in double artery myocardial regions, including the normal donor artery myocardial region (DMR). However, there were no such cases in Group B, giving a significant difference between these 2 groups (p < 0.001). Four patients in Group A, having a perfusion defect both in DMR and in the collateral dependent myocardial region (CMR) underwent a successful percutaneous transluminal coronary angioplasty (PTCA) with disappearance of collaterals. Tl-SPECT findings after PTCA showed no perfusion defect either in CMR or in DMR. This has been explained on the basis that the coronary collaterals stole blood and produced perfusion defect in DMR. (orig.)

  18. The Effects Of L-Arginine And L-Name On Coronary Flow And Oxidative Stress In Isolated Rat Hearts

    Directory of Open Access Journals (Sweden)

    Sobot Tanja

    2015-12-01

    Full Text Available The aim of this experimental study was to assess the effects of the acute administration of L-arginine alone and in combination with L-NAME (a non-selective NO synthase inhibitor on the coronary flow and oxidative stress markers in isolated rat hearts. The experimental study was performed on hearts isolated from Wistar albino rats (n=12, male, 8 weeks old, body mass of 180-200 g. Retrograde perfusion of the isolated preparations was performed using a modified method according to the Langendorff technique with a gradual increase in the perfusion pressure (40–120 cmH2O. The following values were measured in the collected coronary effluents: coronary flow, released nitrites (NO production marker, superoxide anion radical and the index of lipid peroxidation (measured as thiobarbiturate reactive substances. The experimental protocol was performed under controlled conditions, followed by the administration of L-arginine alone (1 mmol and L-arginine (1 mmol + L-NAME (30 μmol. The results indicated that L-arginine did not significantly increase the coronary flow or the release of NO, TBARS and the superoxide anion radical. These effects were partially blocked by the joint administration of L-arginine + L-NAME, which indicated their competitive effect. Hence, the results of our study do not demonstrate significant effects of L-arginine administration on the coronary flow and oxidative stress markers in isolated rat hearts.

  19. Rest/exercise thallium myocardial perfusion imaging: a new and rapid technique to evaluate coronary artery disease

    International Nuclear Information System (INIS)

    Segall, G.M.; Zipkin, R.E.; Stanford Univ., CA

    1993-01-01

    Twenty-six patients underwent conventional exercise/4-h redistribution thallium myocardial perfusion imaging as well as rest/exercise imaging on different days. For the rest/exercise study, patients were inmaged 10 min after receiving 1 mCi thallium at rest. The resting study was immediately followed by symptom-limited treadmill exercise. Patients were injected with 2 mCi thallium at peak exercise and imaged 10 min later. The entire rest/exercise study was completed in 2 h. There was a high degree of correlation between the two studies. Of the 130 segments analysed, 84 were normal and 46 were abnormal by exercise/redistribution imaging whereas 88 were normal and 42 were abnormal by rest/exercise imaging. Among the 14 patients who had coronary arteriography, both exercise/redistribution and rest/exercise imaging correctly identified 23/35 segments as abnormal (sensitivity [pi003] 66% and 34/35 segments as normal (specificity=97%). Furthermore, abnormal segments were more likely to be reversible on the rest/exercise study. The results suggest that the accuracy of rest/exercise thallium imaging is equal to conventional exercise/redistribution imaging in the evaluation of coronary artery disease. The significant time economy and possible improvement in assessing myocardial viability are important potential advantages of this new technique. (Author)

  20. New noninvasive diagnosis of myocardial ischemia of the left circumflex coronary artery using coronary flow reserve measurement by transthoracic Doppler echocardiography. Comparison with thallium-201 single photon emission computed tomography

    International Nuclear Information System (INIS)

    Fujimoto, Kohei; Watanabe, Hiroyuki; Hozumi, Takeshi; Otsuka, Ryo; Hirata, Kumiko; Yamagishi, Hiroyuki; Yoshiyama, Minoru; Yoshikawa, Junichi

    2004-01-01

    The usefulness of coronary flow reserve measurement in the left circumflex coronary artery by transthoracic Doppler echocardiography to detect myocardial ischemia was compared with exercise thallium-201 single photon emission computed tomography (SPECT). Transthoracic Doppler echocardiography was performed in 110 patients with suspected coronary artery disease. Color Doppler signals of the left circumflex coronary artery flow in the apical four-chamber view were identified, and the velocities at rest and during hyperemia recorded for calculation of coronary flow reserve by the pulsed Doppler method. All patients underwent SPECT within 1 week of the transthoracic Doppler echocardiographic study. Coronary flow reserve in the left circumflex coronary artery was measured in 79 (72%) of 110 patients. SPECT revealed reversible perfusion defect in the left circumflex coronary artery territories in 12 of 69 patients excluding those with multivessel disease. Coronary flow reserve <2.0 had a sensitivity of 92% and specificity of 96% for reversible perfusion defect detected by SPECT. Noninvasive coronary flow reserve measurement in the left circumflex coronary artery by transthoracic Doppler echocardiography can estimate myocardial ischemia in the left ventricular lateral regions. (author)

  1. Myocardial perfusion as an indicator of graft patency after coronary artery bypass surgery

    International Nuclear Information System (INIS)

    Kolibash, A.J.; Call, T.D.; Bush, C.A.; Tetalman, M.R.; Lewis, R.P.

    1980-01-01

    Stress and resting myocardial perfusion were assessed in 38 patients who received 96 grafts. Stress perfusion was evaluated with thallium-201 and resting myocardial blood flow distribution with radiolabeled particles. When both stress and rest perfusion were normal, graft patency was 82% (51 of 62 grafts). Graft patency was also high (81%, 13 of 16) in areas where stress perfusion abnormalities resolved or become less apparent at rest. However, when stress perfusion defects remained unchanged at rest, the graf was likely to be occuluded (73%, 11 of 15). Maintenance of normal rest perfusion or improvement of rest perfusion postoperatively was also associated with a high graft patency rate (80%, 35 of 44), whereas the development of new rest perfusion defects postoperatively implied graft occlusion

  2. A relative quantitative assessment of myocardial perfusion by first-pass technique: animal study

    Science.gov (United States)

    Chen, Jun; Zhang, Zhang; Yu, Xuefang; Zhou, Kenneth J.

    2015-03-01

    The purpose of this study is to quantitatively assess the myocardial perfusion by first-pass technique in swine model. Numerous techniques based on the analysis of Computed Tomography (CT) Hounsfield Unit (HU) density have emerged. Although these methods proposed to be able to assess haemodynamically significant coronary artery stenosis, their limitations are noticed. There are still needs to develop some new techniques. Experiments were performed upon five (5) closed-chest swine. Balloon catheters were placed into the coronary artery to simulate different degrees of luminal stenosis. Myocardial Blood Flow (MBF) was measured using color microsphere technique. Fractional Flow Reserve (FFR) was measured using pressure wire. CT examinations were performed twice during First-pass phase under adenosine-stress condition. CT HU Density (HUDCT) and CT HU Density Ratio (HUDRCT) were calculated using the acquired CT images. Our study presents that HUDRCT shows a good (y=0.07245+0.09963x, r2=0.898) correlation with MBF and FFR. In receiver operating characteristic (ROC) curve analyses, HUDRCT provides excellent diagnostic performance for the detection of significant ischemia during adenosine-stress as defined by FFR indicated by the value of Area Under the Curve (AUC) of 0.927. HUDRCT has the potential to be developed as a useful indicator of quantitative assessment of myocardial perfusion.

  3. Ischaemic wound complications in above-knee amputations in relation to the skin perfusion pressure

    DEFF Research Database (Denmark)

    Holstein, P

    1980-01-01

    Healing of the stumps in 59 above-knee amputations was correlated with the local skin perfusion pressure (SPP) measured preoperatively as the external pressure required to stop isotope washout using 131I-(-) or 125I-(-) antipyrine mixed with histamine. Out of the 11 cases with an SPP below 30 mm...... ischaemic wound complications in above-knee amputations as has previously been shown to be the case in below-knee amputations....

  4. Diagnostic value of early post-exercise 99Tcm-MIBI ECG-gated myocardial perfusion imaging in severe coronary artery disease

    International Nuclear Information System (INIS)

    Li Dianfu; Huang Jun; Feng Jianlin; Cheng Xu; Li Xinli; Cao Kejiang

    2005-01-01

    Objective: To study and compare the diagnostic value in severe coronary artery disease (CAD) of 99 Tc m -methoxyisobutylisonitrile (MIBI) electrocardiogram (ECG)-gated early post-exercise myocardial perfusion imaging (G-MPI) with that of non-ECG-gated myocardial perfusion imaging (NG-MPI). Methods: Two hundred and fifteen suspected CAD patients had undergone G-MPI and coronary artery angiography (CAG) within one month were enrolled and distributed into three-vessel and non-three-vessel CAD groups according to CAG results (≥70%); the diagnostic values in severe CAD of G-MPI and NG-MPI were gained and compared to determine which one of the two protocols would be superior in identification of severe three-vessel CAD. Results: When the ≥70% diameter stenosis CAG was the diagnostic standard of severe CAD, the sensitivity of G-MPI and NG-MPI in the diagnosis of severe CAD were 95.3% (143/150) and 90.7% (136/150, χ 2 =2.509, P=0.113), but when the comparison specifically pinpointed to severe three-vessel CAD, there was significant difference between G-MPI [100%(51/51)] and NG-MPI [92.2% (47/51), χ 2 =4.163, P=0.041]. Diagnostic specificity of G-MPI was 80.0% and that of NG-MPI was 72.3% (χ 2 =1.059, P=0.303). Conclusions: The incremental diagnostic sensitivity of G-MPI adding to the NG-MPI in the diagnosis of severe CAD was mainly from the three-vessel subgroup patients. Exercise stress G-MPI has better diagnostic value in severe three-vessel CAD patients than NG-MPI. (authors)

  5. Evaluation of Blood Hemodynamics in Vascular Grafts after Total Arterial Coronary Revascularization

    Directory of Open Access Journals (Sweden)

    Ahmad Ali Amirghofran

    2016-07-01

    Full Text Available Arterial grafting has increasingly been advocated for the treatment of coronary artery disease in an attempt to improve the long-term results. In the quest to perform routine total arterial revascularization, composite Y graft methods are gaining popularity. The aim of our study was to evaluate whether blood flow in the left internal thoracic artery can provide sufficient perfusion to the entire cardiac muscle per se. Twenty patients with severe coronary artery stenosis who underwent complete arterial coronary revascularization using a composite graft entered our study. Blood flow in thoracic trunk was evaluated in three phases: cross-clamp on, cross-clamp off, and after weaning the patient from cardiopulmonary bypass. Mean arterial blood pressure in the thoracic trunk in these various positions was 62.7±3.7. left internal thora cic artery can provide sufficient blood flow to the cardiac muscles for both rest and exercise conditions.

  6. Myocardial perfusion in type 2 diabetes with left ventricular hypertrophy

    DEFF Research Database (Denmark)

    Hesse, Birger; Meyer, Christian; Nielsen, Flemming S

    2004-01-01

    The purpose of this study was to assess whether acute angiotensin-converting enzyme (ACE) inhibition would improve myocardial perfusion and perfusion reserve in a subpopulation of normotensive patients with diabetes and left ventricular hypertrophy (LVH), both independent risk factors of coronary...... disease. Using positron emission tomography (PET), we investigated the response of regional myocardial perfusion to acute ACE inhibition with i.v. infusion of perindoprilat (vs saline infusion as control, minimum interval 3 days) in 12 diabetic patients with LVH. Myocardial perfusion was quantified...... with controls, maximal perfusion was reduced in patients (1.8+/-0.6 vs 2.5+/-1.0 ml min(-1) g(-1); P2.7+/-1.0 vs 3.6+/-1.3; P=0.059). During perindoprilat infusion, myocardial perfusion reserve in patients increased to 3.9+/-0.9 ( P

  7. Influence of risk area size and location on native collateral resistance and ischemic zone perfusion

    International Nuclear Information System (INIS)

    Gumm, D.C.; Cooper, S.M.; Thompson, S.B.; Marcus, M.L.; Harrison, D.C.

    1988-01-01

    To examine the effect of risk area size on collateral resistance and ichemic region perfusion, the authors produced different sized risk areas by occluding either the left anterior descending (LAD) or the circumflex (Cx) coronary artery at different sites. The most proximal occlusion of the LAD and Cx produced risk areas of 43 ± 5 and 36 ± 2% of left ventricular (LV) mass, respectively, whereas distal LAD and Cx occlusions produced risk areas of 13 ± 2 and 17 ± 2% of LV weight, respectively. Although total collateral flow was highest to the largest risk areas, collateral flow per 100 g of ischemic myocardium was 80% higher to the small LAD risk area compared with the large LAD risk area and 43% higher to the small Cx risk area compared with the large Cx risk area. Collateral resistance, calculated from the transcollateral pressure and perfusion per 100 g of myocardium was significantly lower in the small risk areas than in the large ones. They examined the effect of risk area location on collateral perfusion and resistance. These experiments show that collateral resistance is influenced both by ischemic region size and location. Small risk areas receive more collateral flow per mass of tissue than large risk areas, and apical risk areas receive greater quantities of collateral flow than those located at the base. These data may explain why small risk areas often do not develop infarction after coronary occlusion

  8. Sex differences in absolute myocardial perfusion. Non-invasive H2(15)O-PET in young healthy adults.

    Science.gov (United States)

    Range, Felix T; Kies, Peter; Schäfers, Klaus P; Breithardt, Günter; Schober, Otmar; Wichter, Thomas; Schäfers, Michael A

    2016-09-26

    To investigate sex differences in myocardial perfusion especially in healthy individuals since former studies are rare and findings are controversial. Participants, methods: 26 subjects were enrolled: 16 healthy women (age: 34 ±7 years) were compared with 10 healthy men (age: 34 ± 3 years; p = ns). Myocardial blood flow (MBF) and coronary vascular resistance (CVR) were quantified at rest, during adenosine infusion and cold-pressor-testing, using positron emission tomography and radioactive-labelled water (H2(15)O-PET). Women showed higher MBF than men at rest (1.10 ± 0.18 vs. 0.85 ± 0.20 ml/min/ml; p = 0.003) and cold-stress (1.39 ± 0.38 vs. 1.06 ± 0.28 ml/min/ml; p = 0.026). Corrected for rate-pressure-product, baseline findings maintained significance (1.41 ± 0.33 vs. 1.16 ± 0.19 ml/min/ml; p = 0.024). CVR was lower in women at baseline (81 ± 14 vs. 107 ± 22 mmHg*ml(-1)*min*ml; p = 0.006) and during cold-pressor-testing (71 ± 17 vs. 91 ± 20 mmHg*ml(-1)*min*ml; p = 0.013). Under adenosine neither maximal MBF (4.06 ± 1.0 vs. 3.91 ± 0.88 ml/min/ml; p = ns) nor coronary flow reserve (3.07 ± 1.12 vs. 3.44 ± 0.92; p = ns) nor CVR (24 ± 8 vs. 24 ± 6 mmHg*ml(-1)*min*ml; p = ns) showed sex-related differences. Women show higher myocardial perfusion and lower coronary vascular resistance than men in physiologic states. Maximum perfusion and vasodilation under adenosine are not sex-specific.

  9. Increased Regional Epicardial Fat Volume Associated with Reversible Myocardial Ischemia in Patients with Suspected Coronary Artery Disease

    Science.gov (United States)

    Khawaja, Tuba; Greer, Christine; Thadani, Samir R.; Kato, Tomoko S.; Bhatia, Ketan; Shimbo, Daichi; Konkak, Andrew; Bokhari, Sabahat; Einstein, Andrew J.; Schulze, P. Christian

    2015-01-01

    Epicardial adipose tissue is a source of pro-inflammatory cytokines and has been linked to the development of coronary artery disease. No study has systematically assessed the relationship between local epicardial fat volume (EFV) and myocardial perfusion defects. We analyzed EFV in patients undergoing SPECT myocardial perfusion imaging combined with computed tomography (CT) for attenuation correction. Low-dose CT without contrast was performed in 396 consecutive patients undergoing SPECT imaging for evaluation of coronary artery disease. Regional thickness, cross-sectional areas, and total EFV were assessed. 295 patients had normal myocardial perfusion scans and 101 had abnormal perfusion scans. Mean EFVs in normal, ischemic, and infarcted hearts were 99.8 ± 82.3 cm3, 156.4 ± 121.9 cm3, and 96.3 ± 102.1 cm3, respectively (P < 0.001). Reversible perfusion defects were associated with increased local EFV compared to normal perfusion in the distribution of the right (69.2 ± 51.5 vs 46.6 ± 32.0 cm3; P = 0.03) and left anterior descending coronary artery (87.1 ± 76.4 vs 46.7 ± 40.6 cm3; P = 0.005). Our results demonstrate increased regional epicardial fat in patients with active myocardial ischemia compared to patients with myocardial scar or normal perfusion on nuclear perfusion scans. Our results suggest a potential role for cardiac CT to improve risk stratification in patients with suspected coronary artery disease. PMID:25339129

  10. Machine learning improves the accuracy of myocardial perfusion scintigraphy results

    International Nuclear Information System (INIS)

    Groselj, C.; Kukar, M.

    2002-01-01

    Objective: Machine learning (ML) an artificial intelligence method has in last decade proved to be an useful tool in many fields of decision making, also in some fields of medicine. By reports, its decision accuracy usually exceeds the human one. Aim: To assess applicability of ML in interpretation of the stress myocardial perfusion scintigraphy results in coronary artery disease diagnostic process. Patients and methods: The 327 patient's data of planar stress myocardial perfusion scintigraphy were reevaluated in usual way. Comparing them with the results of coronary angiography the sensitivity, specificity and accuracy of the investigation were computed. The data were digitized and the decision procedure repeated by ML program 'Naive Bayesian classifier'. As the ML is able to simultaneously manipulate with whatever number of data, all reachable disease connected data (regarding history, habitus, risk factors, stress results) were added. The sensitivity, specificity and accuracy of scintigraphy were expressed in this way. The results of both decision procedures were compared. Conclusion: Using ML method, 19 more patients out of 327 (5.8%) were correctly diagnosed by stress myocardial perfusion scintigraphy. In this way ML could be an important tool for myocardial perfusion scintigraphy decision making

  11. Adenosine stress cardiovascular magnetic resonance with variable-density spiral pulse sequences accurately detects coronary artery disease: initial clinical evaluation.

    Science.gov (United States)

    Salerno, Michael; Taylor, Angela; Yang, Yang; Kuruvilla, Sujith; Ragosta, Michael; Meyer, Craig H; Kramer, Christopher M

    2014-07-01

    Adenosine stress cardiovascular magnetic resonance perfusion imaging can be limited by motion-induced dark-rim artifacts, which may be mistaken for true perfusion abnormalities. A high-resolution variable-density spiral pulse sequence with a novel density compensation strategy has been shown to reduce dark-rim artifacts in first-pass perfusion imaging. We aimed to assess the clinical performance of adenosine stress cardiovascular magnetic resonance using this new perfusion sequence to detect obstructive coronary artery disease. Cardiovascular magnetic resonance perfusion imaging was performed during adenosine stress (140 μg/kg per minute) and at rest on a Siemens 1.5-T Avanto scanner in 41 subjects with chest pain scheduled for coronary angiography. Perfusion images were acquired during injection of 0.1 mmol/kg Gadolinium-diethylenetriaminepentacetate at 3 short-axis locations using a saturation recovery interleaved variable-density spiral pulse sequence. Significant stenosis was defined as >50% by quantitative coronary angiography. Two blinded reviewers evaluated the perfusion images for the presence of adenosine-induced perfusion abnormalities and assessed image quality using a 5-point scale (1 [poor] to 5 [excellent]). The prevalence of obstructive coronary artery disease by quantitative coronary angiography was 68%. The average sensitivity, specificity, and accuracy were 89%, 85%, and 88%, respectively, with a positive predictive value and negative predictive value of 93% and 79%, respectively. The average image quality score was 4.4±0.7, with only 1 study with more than mild dark-rim artifacts. There was good inter-reader reliability with a κ statistic of 0.67. Spiral adenosine stress cardiovascular magnetic resonance results in high diagnostic accuracy for the detection of obstructive coronary artery disease with excellent image quality and minimal dark-rim artifacts. © 2014 American Heart Association, Inc.

  12. Cost-effectiveness of substituting dual-energy CT for SPECT in the assessment of myocardial perfusion for the workup of coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, Mathias [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim–Heidelberg University, Mannheim (Germany); Nance, John W. [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Medicine, Division of Cardiology, Medical University of South Carolina, Charleston, SC (United States); Moscariello, Antonio [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Bioimaging and Radiological Sciences, Catholic University of Sacred Heart, “A. Gemelli” Hospital, Rome (Italy); Weininger, Markus; Rowe, Garrett W.; Ruzsics, Balazs [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Kang, Doo Kyoung [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiology, Ajou University School of Medicine, Suwon (Korea, Republic of); Chiaramida, Salvatore A. [Department of Medicine, Division of Cardiology, Medical University of South Carolina, Charleston, SC (United States); Schoenberg, Stefan O.; Fink, Christian [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim–Heidelberg University, Mannheim (Germany); and others

    2012-12-15

    Purpose: We compared cost-effectiveness and potential lifetime benefits of using dual-energy computed tomography (DECT) for myocardial perfusion assessment instead of single photon emission computed tomography (SPECT) for the workup of coronary artery disease (CAD). Materials and methods: A decision and simulation model was developed to estimate cost and health effects of using DECT myocardial perfusion imaging instead of SPECT for identifying patients in need of invasive imaging and possible revascularization. The model was based on the performance indices of stress/rest DECT compared with stress/rest SPECT for detecting myocardial perfusion deficits in 50 patients (mean age 61 ± 10 years) with CAD. Stress/rest perfusion and delayed enhancement cardiac MRI served as reference standard. For DECT a reimbursement of US$1700 was assumed but costs of cardiac MRI were not included in the model. All other actual healthcare costs in these patients were derived from MUSC's hospital billing system. Results: Compared with cardiac MRI, DECT (versus SPECT) had 90% (85%) sensitivity and 71% (58%) specificity for identifying patients with obstructive CAD. Compared with the no imaging and no treatment strategy, routine SPECT gained 13.49 quality-adjusted life-years (QALYs) with an incremental cost-effectiveness ratio (ICER) of US$3557 (in 2010) per QALY. In comparison, DECT ICER was lower (US$3.191 per QALY, p = 0.0002) and an additional 0.64 QALYs was obtained (total of 14.13 QALYs) if compared with the SPECT strategy as well as the no imaging and no treatment strategy. Conclusion: Using DECT as the first-line imaging test for myocardial perfusion for the workup of patients with CAD has the potential to provide gains in QALYs, while lowering costs if compared to routine myocardial perfusion SPECT.

  13. Withholding or Continuing Beta-Blocker Treatment Before Dipyridamole Myocardial Perfusion Imaging for the Diagnosis of Coronary Artery Disease? a Randomized Clinical Trial

    Directory of Open Access Journals (Sweden)

    Babak Fallahi

    2013-01-01

    Full Text Available Although it has been shown that acute beta-blocker administration may reduce the presence or severity of myocardial perfusion defects with dipyridamole stress, little information is available about the potential effect of chronic beta-blocker treatment on the sensitivity of dipyridamole myocardial perfusion imaging (DMPI.Methods As a randomized clinical trial, one hundred twenty patients (103 male and 17 female with angiographically confirmed CAD who were on long-term beta blocker therapy ([greater than or equal to]3 months enrolled in a randomized clinical trial study. The patients were allocated into two groups: Group A (n=60 in whom the beta-blocker agent was discontinued for 72h before DMPI and Group B (n=60 without discontinuation of beta-blockers prior to DMPI.ResultsNo significant difference was noted between the groups concerning age, sex, type of the injected radiotracer and number of involved coronary vessels. The mean rank of total perfusion scores for whole myocardium (irrespective of reversibility or irreversibility in group B was not significantly different from that of group A, (65.75 vs. 55.25, P=0.096. Regarding the only irreversible perfusion defects, the mean rank of perfusion score in group B was higher than that of group A for whole myocardium (72 vs. 49, P=0.0001; however, no difference was noted between two groups for only reversible perfusion defects (61.0 vs. 60.0, P=0.898. The overall sensitivity of DMPI for the diagnosis of CAD in group A (91.7% was not statistically different from group B (90%.ConclusionBeta-blocker withholding before DMPI did not generally affect the sensitivity of the test for the diagnostic purposes in our study. Thus, beta-blocker withdrawal for just the purpose of diagnostic imaging is not mandatory particularly when medication discontinuation may cause the patients to face increased risk of heart events.

  14. Cost-effectiveness of substituting dual-energy CT for SPECT in the assessment of myocardial perfusion for the workup of coronary artery disease

    International Nuclear Information System (INIS)

    Meyer, Mathias; Nance, John W.; Schoepf, U. Joseph; Moscariello, Antonio; Weininger, Markus; Rowe, Garrett W.; Ruzsics, Balazs; Kang, Doo Kyoung; Chiaramida, Salvatore A.; Schoenberg, Stefan O.; Fink, Christian

    2012-01-01

    Purpose: We compared cost-effectiveness and potential lifetime benefits of using dual-energy computed tomography (DECT) for myocardial perfusion assessment instead of single photon emission computed tomography (SPECT) for the workup of coronary artery disease (CAD). Materials and methods: A decision and simulation model was developed to estimate cost and health effects of using DECT myocardial perfusion imaging instead of SPECT for identifying patients in need of invasive imaging and possible revascularization. The model was based on the performance indices of stress/rest DECT compared with stress/rest SPECT for detecting myocardial perfusion deficits in 50 patients (mean age 61 ± 10 years) with CAD. Stress/rest perfusion and delayed enhancement cardiac MRI served as reference standard. For DECT a reimbursement of US$1700 was assumed but costs of cardiac MRI were not included in the model. All other actual healthcare costs in these patients were derived from MUSC's hospital billing system. Results: Compared with cardiac MRI, DECT (versus SPECT) had 90% (85%) sensitivity and 71% (58%) specificity for identifying patients with obstructive CAD. Compared with the no imaging and no treatment strategy, routine SPECT gained 13.49 quality-adjusted life-years (QALYs) with an incremental cost-effectiveness ratio (ICER) of US$3557 (in 2010) per QALY. In comparison, DECT ICER was lower (US$3.191 per QALY, p = 0.0002) and an additional 0.64 QALYs was obtained (total of 14.13 QALYs) if compared with the SPECT strategy as well as the no imaging and no treatment strategy. Conclusion: Using DECT as the first-line imaging test for myocardial perfusion for the workup of patients with CAD has the potential to provide gains in QALYs, while lowering costs if compared to routine myocardial perfusion SPECT.

  15. [Myocardial perfusion imaging by digital subtraction angiography].

    Science.gov (United States)

    Kadowaki, H; Ishikawa, K; Ogai, T; Katori, R

    1986-03-01

    Several methods of digital subtraction angiography (DSA) were compared to determine which could better visualize regional myocardial perfusion using coronary angiography in seven patients with myocardial infarction, two with angina pectoris and five with normal coronary arteries. Satisfactory DSA was judged to be achieved if the shape of the heart on the mask film was identical to that on the live film and if both films were exactly superimposed. To obtain an identical mask film in the shape of each live film, both films were selected from the following three phases of the cardiac cycle; at the R wave of the electrocardiogram, 100 msec before the R wave, and 200 msec before the R wave. The last two were superior for obtaining mask and live films which were similar in shape, because the cardiac motion in these phases was relatively small. Using these mask and live films, DSA was performed either with the continuous image mode (CI mode) or the time interval difference mode (TID mode). The overall perfusion of contrast medium through the artery to the vein was adequately visualized using the CI mode. Passage of contrast medium through the artery, capillary and vein was visualized at each phase using TID mode. Subtracted images were displayed and photographed, and the density of the contrast medium was adequate to display contour lines as in a relief map. Using this DSA, it was found that regional perfusion of the contrast medium was not always uniform in normal subjects, depending on the typography of the coronary artery.(ABSTRACT TRUNCATED AT 250 WORDS)

  16. Myocardial images in nonacute coronary and noncoronary heart diseases

    International Nuclear Information System (INIS)

    Poe, N.D.; Eber, L.M.; Norman, A.S.; Selin, C.E.; Terao, E.N.

    1977-01-01

    To determine the variables that might affect interpretability of myocardial perfusion images in patients with acute myocardial infarctions, images obtained following intravenous administration of potassium-43 or cesium-129 were evaluated in 68 patients with nonacute coronary or noncoronary heart diseases, who were undergoing cardiac catheterization. Severe coronary arterial disease usually produces no distinctive perfusion defects in the resting state. Remote infarcts likewise tend to remain undetectable unless accompanied by wall-motion disturbances that can be detected by ventriculography. Left ventricular hypertrophy or cardiac dilatation can produce perfusion patterns indistinguishable from the ischemic defects of infarction. Right ventricular hypertrophy can cause image alterations that mimic infarcts in the left ventricle. In patients with acute myocardial infarction, sequential imaging studies with perfusion indicators should be of value in determining the effects of various therapeutic maneuvers on regional myocardial perfusion, but variations caused by conditions other than acute vascular occlusion limit the usefulness of perfusion imaging for diagnosing acute infarction. In suspected acute infarction, perfusion imaging will be used most effectively in conjunction with other imaging or nonimaging procedures that show the presence of damaged or necrotic myocardium. The information derived from this study should be generally applicable to the interpretation of imaging results obtained with the newer indicators of myocardial perfusion now in use or under development

  17. Influence of revascularization on myocardial perfusion, metabolism and function

    International Nuclear Information System (INIS)

    Kropp, Joachim; Krois, Markus; Eichhorn, Bernd; Fehske, Wolfgang; Likungu, James; Kirchhoff, P.G.; Luederitz, Berndt; Biersack, Hans-Juergen; Knapp, F.F. Jr.

    1993-01-01

    Thirty-nine patients with coronary artery disease (CAD) were investigated with sequential SPECT-scintigraphy after administration of 200 MBq of 15-(p-[I-123]iodophenyl)pentadecanoic acid (IPPA) at peak submaximal exercise. Twenty patients underwent coronary angioplasty (PTCA) from which 14 had control coronary arteriography (CA) and left ventricular cineventriculography (LVCV). Nineteen patients underwent bypass graft surgery (ACB) and stress sonography. Semi-quantification of uptake (Up, related to perfusion) and turnover (Tr, linked to metabolism) was obtained by segmental comparison of oblique slices. About 90% of the reperfused myocardial segments in the PTCA-group and 76% in the ACB-group showed an improvement of uptake after therapy (RUp). Out of these, 50% and 66% exhibited increased turnover (RTr) after PTCA or ACB, respectively. The remaining segments had persistingly pathologic RTr indicating a dissociation of improvement of perfusion and metabolism after therapy. Pathologic RTr was highly correlated with regional wall motion abnormalities (RWMA) after therapy in both groups. In the ACB-group improvement in RTr was correlated with improved RWM at rest and stress in 86% and 92%, respectively, whereas no improvement in RTr was correlated with impared function in 100% and 52%, respectively. IPPA-studies show potential to provide information about changes of perfusion and metabolism after reperfusion and IPPA-turnover is a good predictor of the pattern of contractile function. (author)

  18. Dipyridamole-thallium-201 tomography documenting improved myocardial perfusion with therapy in Kawasaki disease

    International Nuclear Information System (INIS)

    Nienaber, C.A.; Spielmann, R.P.; Hausdorf, G.

    1988-01-01

    Thallium-201 tomographic perfusion studies after pharmacologic vasodilation were performed in seven children (aged 2 years 8 months to 8 years 7 months), 3 to 20 months after the acute stage of the disease. In all patients coronary aneurysms were seen on cross-sectional echocardiograms. The scintigrams of six children showed no significant regional reduction of myocardial thallium-201 uptake. These children had remained asymptomatic in the follow-up period after the acute inflammatory stage of Kawasaki disease. Persistent and transient thallium defects were present in one child with acute posterolateral myocardial infarction; obstruction of two coronary vessels supplying the defect zones was confirmed by contrast angiography. After 8 months of treatment a follow-up nuclear scan showed marked reduction in the size of the defect and almost complete abolishment of the ischemic reaction. Thus tomographic thallium-201 perfusion scintigraphy in conjunction with vasodilation stress is useful to assess myocardial perfusion in children with Kawasaki disease and demonstrates marked improvement in regional perfusion after adequate medical therapy

  19. CT myocardial perfusion imaging: current status and future perspectives.

    Science.gov (United States)

    Yang, Dong Hyun; Kim, Young-Hak

    2017-07-01

    Computed tomography myocardial perfusion (CTP) combined with coronary computed tomography angiography (CCTA) may constitute a "1-stop shop" for the noninvasive diagnosis of hemodynamically significant coronary stenosis during a single CT examination. CTP shows high diagnostic performance and provides incremental value over CCTA for the detection of hemodynamically significant coronary stenosis in patients with a high Agatston calcium score or coronary artery stents. Future studies should determine the optimal protocol and clinical value of CTP for guiding revascularization strategy and prognostication. In this article, we review the current status and future perspectives of CTP, focusing on technical considerations, clinical applications, and future research topics.

  20. Long-term effect of prazosin administration on blood pressure, heart and structure of coronary artery of young spontaneously hypertensive rats.

    Science.gov (United States)

    Kristek, F; Koprdova, R

    2011-06-01

    The sympathetic nervous system belongs to the essential systems participating in blood pressure (BP) regulation. Inhibitory intervention into the key point of its operation (alfa 1 adrenoceptors) in the prehypertensive period of spontaneously hypertensive rats (SHR) might affect the development of the hypertension in later ontogenic periods. We studied the long-term effect of prazosin administration on the cardiovascular system of young Wistar rats and SHR. Four-week-old animals were used: Wistar rats, SHR, and Wistar rats and SHR receiving prazosin (10 mg/kg/day in tap water) by gavage. Blood pressure (BP) was measured weekly by the plethysmographic method. After six weeks under anaesthesia, the carotid artery was cannulated for BP registration, and the jugular vein was cannulated for administration of drugs. Afterwards, the animals were perfused with a glutaraldehyde fixative at a pressure of 120 mmHg. The septal branch of the left descending coronary artery was processed using electron microscopy. The prazosin administration evoked the following results in both groups: a decrease of BP and heart/body weight ratio, enhancement of hypotensive responses to acetylcholine (0.1 μg, 1 μg, and 10 μg), and an increase in the inner diameter of the coronary artery without changes in wall thickness, cross sectional area (CSA) (tunica intima+media), CSA of smooth muscle cells, and extracellular matrix. In the SHR group, a reduction was observed in BP increase after noradrenaline (1 μg) application. CSA of endothelial cells which was decreased in the SHR (compared to the control Wistar rats) was increased after prazosin treatment (up to control value). Long-term prazosin administration from early ontogeny partially prevented some pathological alterations in the cardiovascular system of SHR.

  1. Myocardial perfusion abnormalities in asymptomatic patients with systemic lupus erythematosus

    International Nuclear Information System (INIS)

    Hosenpud, J.D.; Montanaro, A.; Hart, M.V.; Haines, J.E.; Specht, H.D.; Bennett, R.M.; Kloster, F.E.

    1984-01-01

    Accelerated coronary artery disease and myocardial infarction in young patients with systemic lupus erythematosus is well documented; however, the prevalence of coronary involvement is unknown. Accordingly, 26 patients with systemic lupus were selected irrespective of previous cardiac history to undergo exercise thallium-201 cardiac scintigraphy. Segmental perfusion abnormalities were present in 10 of the 26 studies (38.5 percent). Five patients had reversible defects suggesting ischemia, four patients had persistent defects consistent with scar, and one patient had both reversible and persistent defects in two areas. There was no correlation between positive thallium results and duration of disease, amount of corticosteroid treatment, major organ system involvement or age. Only a history of pericarditis appeared to be associated with positive thallium-201 results (p less than 0.05). It is concluded that segmental myocardial perfusion abnormalities are common in patients with systemic lupus erythematosus. Whether this reflects large-vessel coronary disease or small-vessel abnormalities remains to be determined

  2. The use of hemoglobin saturation ratio as a means of measuring tissue perfusion in the development of heel pressure sores.

    Science.gov (United States)

    Aliano, Kristen A; Stavrides, Steve; Davenport, Thomas

    2013-09-01

    The heel is a common site of pressure ulcers. The amount of pressure and time needed to develop these wounds is dependent on various factors including pressure surface, the patient's anatomy, and co-morbidities. We studied the use of the hemoglobin saturation ratio as a means of assessing heel perfusion in various pressure settings. The mixed perfusion ratio in the heels of 5 volunteers was assessed on 3 pressure surfaces and at the time of off-load. The surfaces studied included: stretcher pad, plastic backboard without padding, and pressure reduction gel. Each surface was measured for 5 minutes with a real-time reading. On the stretcher, the average StO2% decrease for each pressure surface was 26.2 ± 10 (range 18-43). The average StO2% decrease on the backboard was 22.8 ± 12.3 (range 8-37), and 24.0 ± 4.8 (range 19-30) on the gel pad. The StO2% drop plateaued with the stretcher and gel pad, but with the backboard there was a continued slow drop at 5 minutes. This study demonstrates that hemoglobin oxygenation ratio may be effective in assessing a tissue's direct perfusion in the setting of tissue pressure and may also be beneficial to better assess the effects of pressure-reduction surfaces. Further studies will be needed to determine time to skin breakdown as it pertains to pressure and tissue oxygenation.

  3. System analysis of the dynamic response of the coronary circulation to a sudden change in heart rate.

    Science.gov (United States)

    Dankelman, J; Stassen, H G; Spaan, J A

    1990-03-01

    In this study the response of driving pressure/flow ration on an abrupt change in heart rate was analysed. The difference between the response obtained with constant pressure and constant flow perfusion was also studied. The responses show a fast initial reversed phase followed by a slow phase caused by regulation. To test whether the initial phase could be the result of mechanical changes in the coronary circulation, a model for regulation was extended by the addition of four different mechanical models originating from the literature. These extended models were able to explain the fast initial phase. However, the mechanical model consisting of an intramyocardial compliance (C = 0.08 ml mm Hg-1 100 g-1) with a variable venous resistance, and the model consisting of a waterfall and a small compliance (C = 0.007 ml mm Hg-1 100g-1) both explained these responses best. The analysis showed that there is no direct relationship between rate of change of vascular tone and rate of change of pressure/flow ratio. However, on the basis of the two extended models, it can be predicted that the half-time for the response of regulation to be complete is about 9s with constant pressure perfusion and 15 s with constant flow perfusion.

  4. The diagnosis of silent myocardial ischemia. Motion-Frozen (or morphing) myocardial perfusion imaging.

    Science.gov (United States)

    Chang, Cheng; Ye, Bo; Xie, Wenhui; Zhang, Daoliang; Lei, Bei; Ye, Xiaodan

    2016-01-01

    Silent myocardial ischemia is typically defined as objective evidence of myocardial ischemia in patients without subjective ischemia symptoms. Currently, coronary artery angiography is the gold standard for diagnosis of asymptomatic coronary artery disease (CAD). Computed tomography coronary angiography (CTCA) can visually demonstrate the morphology, trend and extent of coronary stenosis and is commonly used in clinical screening of CAD. Myocardial perfusion imaging can be used not only to identify whether anatomical stenosis causes myocardial dysfunction, but to also assess the risk stratification and prognosis of myocardial disease (MD). Myocardial perfusion imaging using morphing combined with CTCA can simultaneously show the relationship between CAD and myocardial ischemia from an anatomical and functional aspect. This allows earlier diagnosis of asymptomatic CAD myocardial ischemia, accurate identification of the culprit vessels, and could prevent unnecessary interventional therapy. The 1-day dobutamine stress/resting met-hod is also one of the methods used. The combination of CTCA and the morphing technique can provide anatomical and functional information on coronary arteries at the same time, significantly improving the diagnostic sensitivity, specificity, and accuracy of MD.

  5. Presurgical evaluation of cerebral perfusion reserve in patients for cardiovascular surgery using {sup 99m}Tc-ECD SPECT with diamox enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Matsumura, Kaname; Nakashima, Hiromichi; Tanaka, Kuniyoshi; Kitano, Tokio; Murashima, Shuichi; Takeda, Kan; Yuasa, Hiroshi; Yada, Isao; Nakagawa, Tsuyoshi [Mie Univ., Tsu (Japan). School of Medicine

    1996-03-01

    Cerebrovascular stroke is one of the major complications in cardiovascular surgery with cardiopulmonary bypass. The purpose of this study was to evaluate the usefulness of preoperative {sup 99m}Tc-ethyl cysteinate dimer (ECD) SPECT and acetazolamide (diamox) enhancement to predict neurological complications in cardiovascular surgery. Eighteen patients with coronary disease, valvular disease or aortic aneurysm were studied before the operations. Regional cerebral blood flow and perfusion reserve were evaluated using ECD SPECT before and after the intravenous administration of diamox (1 g). Three cases with moderate to severe baseline abnormalities and poor perfusion reserve had cerebral infarction postoperatively. Twelve cases with good to fair perfusion reserve had no neurological complication. Three cases having poor perfusion reserve had the operations with more intensive brain protection, in which higher perfusion pressure to the brain was maintained during cardiopulmonary bypass, and no neurological complication was observed. In conclusion, patients who have moderately or markedly abnormal baseline flow with poor perfusion reserve may have some risk of neurological complications in cardiovascular surgery. ECD SPECT with diamox enhancement may give information useful for selection of operation procedures. (author).

  6. Role of myocardial perfusion single photon emission computed tomography in pediatric cardiology practice

    Directory of Open Access Journals (Sweden)

    Sundaram P

    2009-01-01

    Full Text Available Diagnostic and prognostic power of myocardial perfusion imaging in patients with coronary artery disease has been demonstrated with planar imaging which was further improvised with addition of gated SPECT and newer Technetium labeled myocardial perfusion tracers like SestaMIBI, Tetrofosmin. Myocardial perfusion abnormalities at rest and after stress are considered to be the best predictors of cardiac event-free survival in adults with ischemic heart disease. This article highlights various myocardial perfusion imaging (MPIradiopharmaceuticals, exercise procedures, pharmacological stress protocols, indications for MPI and myocardial perfusion patterns in children with some of the common congenital and acquired heart diseases.

  7. Candida glabrata binds to glycosylated and lectinic receptors on the coronary endothelial luminal membrane and inhibits flow sense and cardiac responses to agonists.

    Science.gov (United States)

    Torres-Tirado, David; Knabb, Maureen; Castaño, Irene; Patrón-Soberano, Araceli; De Las Peñas, Alejandro; Rubio, Rafael

    2016-01-01

    Candida glabrata (CG) is an opportunistic fungal pathogen that initiates infection by binding to host cells via specific lectin-like adhesin proteins. We have previously shown the importance of lectin-oligosaccharide binding in cardiac responses to flow and agonists. Because of the lectinic-oligosaccharide nature of CG binding, we tested the ability of CG to alter the agonist- and flow-induced changes in cardiac function in isolated perfused guinea pig hearts. Both transmission and scanning electron microscopy showed strong attachment of CG to the coronary endothelium, even after extensive washing. CG shifted the coronary flow vs. auricular-ventricular (AV) delay relationship upward, indicating that greater flow was required to achieve the same AV delay. This effect was completely reversed with mannose, partially reversed with galactose and N-acetylgalactosamine, but hyaluronan had no effect. Western blot analysis was used to determine binding of CG to isolated coronary endothelial luminal membrane (CELM) receptors, and the results indicate that flow-sensitive CELM receptors, ANG II type I, α-adrenergic 1A receptor, endothelin-2, and VCAM-1 bind to CG. In addition, CG inhibited agonist-induced effects of bradykinin, angiotensin, and phenylephrine on AV delay, coronary perfusion pressure, and left ventricular pressure. Mannose reversed the inhibitory effects of CG on the agonist responses. These results suggest that CG directly binds to flow-sensitive CELM receptors via lectinic-oligosaccharide interactions with mannose and disrupts the lectin-oligosaccharide binding necessary for flow-induced cardiac responses. Copyright © 2016 the American Physiological Society.

  8. Diagnosis and prognosis of elderly patients with coronary artery disease. Assessment with dipyridamole thallium imaging

    International Nuclear Information System (INIS)

    Yamasaki, Fumiyasu; Takata, Jun; Seo, Hiromi; Chikamori, Taishiro; Yamada, Mitsutoshi; Yabe, Toshikazu; Doi, Yoshinori

    1995-01-01

    The diagnostic and prognostic value of dipyridamole perfusion scintigraphy was assessed in 147 patients with coronary artery disease aged 65 years and older. All patients underwent coronary angiography. Dipyridamole perfusion scintigraphy was performed safely in all patients. Multiple regression analysis showed that fixed defect and reversible defect were powerful detectors of coronary lesions, all patients with fixed disease and 94% of patients with only reversible defects had significant coronary lesion. Diffuse slow washout and ST depression were statistically significant for detection multivessel coronary lesions in patients with fixed disease, the sensitivity and specificity of diffuse slow washout and/or ST depression for detecting multivessel coronary lesions were 85% and 74%, respectively. Cox survival analysis identified diffuse slow washout as the best predictor of future cardiac events among the scintigraphic variables. Univariate analysis showed the best predictors were age (≥70), diffuse slow washout, and severe coronary lesions. Multivariate analysis showed diffuse slow washout and severe coronary lesions were the best predictors. Dividing the patients by age (≥70) showed that age and diffuse slow washout were good predictors. Scintigraphic and angiographic parameters found diffuse slow washout was the only good predictor. Dipyridamole perfusion scintigraphy is useful for the noninvasive detection of significant coronary artery disease in the elderly, and for predicting future cardiac events with similar predictability to angiographic findings. (S.Y.)

  9. Coronary microembolization with normal epicardial coronary arteries and no visible infarcts on nitrobluetetrazolium chloride-stained specimens: Evaluation with cardiac magnetic resonance imaging in a swine model

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Hang; Yun, Hong; Zeng, Meng Su [Dept. of Radiology, Zhongshan Hospital, Fudan University and Shanghai Institute of Medical Imaging, Shanghai (China); Ma, Jian Ying; Chen, Zhang Wei; Chang, Shu Fu [Dept. of Cardiology, Zhongshan Hospital, Fudan University and Shanghai Institute of Cardiovascular Diseases, Shanghai (China)

    2016-02-15

    To assess magnetic resonance imaging (MRI) features of coronary microembolization in a swine model induced by small-sized microemboli, which may cause microinfarcts invisible to the naked eye. Eleven pigs underwent intracoronary injection of small-sized microspheres (42 µm) and catheter coronary angiography was obtained before and after microembolization. Cardiac MRI and measurement of cardiac troponin T (cTnT) were performed at baseline, 6 hours, and 1 week after microembolization. Postmortem evaluation was performed after completion of the imaging studies. Coronary angiography pre- and post-microembolization revealed normal epicardial coronary arteries. Systolic wall thickening of the microembolized regions decreased significantly from 42.6 ± 2.0% at baseline to 20.3 ± 2.3% at 6 hours and 31.5 ± 2.1% at 1 week after coronary microembolization (p < 0.001 for both). First-pass perfusion defect was visualized at 6 hours but the extent was largely decreased at 1 week. Delayed contrast enhancement MRI (DE-MRI) demonstrated hyperenhancement within the target area at 6 hours but not at 1 week. The microinfarcts on gross specimen stained with nitrobluetetrazolium chloride were invisible to the naked eye and only detectable microscopically. Increased cTnT was observed at 6 hours and 1 week after microembolization. Coronary microembolization induced by a certain load of small-sized microemboli may result in microinfarcts invisible to the naked eye with normal epicardial coronary arteries. MRI features of myocardial impairment secondary to such microembolization include the decline in left ventricular function and myocardial perfusion at cine and first-pass perfusion imaging, and transient hyperenhancement at DE-MRI.

  10. [Surgical angioplasty of the left main coronary artery].

    Science.gov (United States)

    Vranes, Mile; Velinović, Milos; Kocica, Mladen; Mikić, Aleksandar; Velimirović, Dusan; Djukić, Petar

    2010-01-01

    The conventional treatment for isolated stenosis of the left main coronary artery is bypass surgery (myocardial revascularization). However, the process of atherosclerosis is not arrested by myocardial revascularization and it will lead to the occlusion of the left main coronary artery. Revascularization will establish retrograde perfusion for 50-70% of the myocardium of the left ventricle. Direct surgical angioplasty of the left main coronary artery enables normal physiological perfusion of the whole myocardium and better myocardial function. The aim of our study is to point out a new surgical approach of treating left main coronary artery stenosis. Between October 2002 and October 2003, direct surgical angioplasty of the main left coronary artery was performed on three patients with isolated stenosis of the left main coronary artery using the anterior approach and the pericardium as a patch. The procedure was performed under total endotracheal anaesthesia and standard cardiopulmonary circulation, moderate hypothermia, anterograde St. Tomas cardioplegia and local cooling. Patients were followed clinically, echocardiographically and by load-tests. All three patients were without complications. In postoperative follow-up (54-68 months) neither angina pectoris nor electrocardiographically registered ischaemic changes were found. Load-tests performed every six months on all three patients were negative. Surgical angioplasty of isolated stenosis of the left main coronary artery is a preferred method for treating this type of coronary disease. Contraindications for this type of treatment are stenosis of the left main coronary artery with bifurcation and advanced calcification of the left main coronary artery.

  11. Influence of a pressure gradient distal to implanted bare-metal stent on in-stent restenosis after percutaneous coronary intervention

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per; Thuesen, Leif

    2007-01-01

    pullback recording in the entire length of the artery. METHODS AND RESULTS: In 98 patients with angina pectoris, 1 de novo coronary lesion was treated with a bare-metal stent. After stent implantation, pressure wire measurements (P(d)=mean hyperemic coronary pressure and P(a)=mean aortic pressure) were......-stent restenosis after 9 months. CONCLUSIONS: A residual abnormal P(d)/P(a) distal to a bare-metal stent was an independent predictor of in-stent restenosis after implantation of a coronary bare-metal stent. Udgivelsesdato: 2007-Dec-11......BACKGROUND: Fractional flow reserve predicts cardiac events after coronary stent implantation. The aim of the present study was to assess the 9-month angiographic in-stent restenosis rate in the setting of optimal stenting and a persisting gradient distal to the stent as assessed by a pressure wire...

  12. CT myocardial perfusion imaging. Ready for prime time?

    Energy Technology Data Exchange (ETDEWEB)

    Takx, Richard A.P.; Celeng, Csilla [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Schoepf, U.J. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Medical University of South Carolina, Ashley River Tower, Heart and Vascular Center, Charleston, SC (United States)

    2018-03-15

    The detection of functional coronary artery stenosis with coronary CT angiography (CCTA) is suboptimal. Additional CT myocardial perfusion imaging (CT-MPI) may be helpful to identify patients with myocardial ischaemia in whom coronary revascularization therapy would be beneficial. CT-MPI adds incremental diagnostic and prognostic value over obstructive disease on CCTA. It allows for the quantitation of myocardial blood flow and calculation of coronary flow reserve and shows good correlation with {sup 15}O-H{sub 2}O positron emission tomography and invasive fractional flow reserve. In addition, patients prefer CCTA/CT-MPI over SPECT, MRI and invasive coronary angiography. CT-MPI is ready for clinical use for detecting myocardial ischaemia caused by obstructive disease. Nevertheless, the clinical utility of CT-MPI to identify ischaemia in patients with non-obstructive/microvascular disease still has to be established. (orig.)

  13. Wound healing in above-knee amputations in relation to skin perfusion pressure

    DEFF Research Database (Denmark)

    Holstein, P; Dovey, H; Lassen, N A

    1979-01-01

    In 59 above-knee amputations healing of the stumps was correlated with the local skin perfusion pressure (SPP) measured preoperatively as the external pressure required to stop isotope washout using 1318-- or 125I--antipyrine mixed with histamine. Out of the 11 cases with an SPP below 30 mm...... on the stumps was on average only slightly and insignificantly higher than the preoperative values, explaining why the preoperative values related so closely to the postoperative clinical course. We conclude that the SPP can be used to predict ischaemic wound complications in above-knee amputations as has...... previously been shown to be the case in below-knee amputations....

  14. Predicting late restenosis after coronary angioplasty by very early (12 to 24 h) thallium-201 scintigraphy: Implications with regard to mechanisms of late coronary restenosis

    International Nuclear Information System (INIS)

    Hardoff, R.; Shefer, A.; Gips, S.; Merdler, A.; Flugelman, M.Y.; Halon, D.A.; Lewis, B.S.

    1990-01-01

    To examine whether late coronary restenosis may be predicted by abnormalities of myocardial perfusion in the early hours after successful percutaneous transluminal coronary angioplasty and to study in greater detail the mechanisms involved in the development of late coronary restenosis after angioplasty, a prospective study was undertaken in 90 consecutive patients. Thallium-201 scintigrams were recorded at rest and during the stress of atrial pacing, 12 to 24 h after angioplasty, and the results were related to the findings at angiography in 70 patients undergoing late cardiac catheterization. A reversible thallium-201 perfusion defect was found in 39 (38%) of 104 myocardial regions supplied by the dilated coronary vessel and identified a subset of patients at high risk of late (6 to 12 months) angiographic restenosis (sensitivity 77%, specificity 67%). In contrast, late coronary restenosis developed in only 7 (11%) of 65 vessels and in 5 (14%) of 37 patients with a nonischemic thallium-201 scintigram on day 1 (p less than 0.005). Multivariate logistic regression analysis of 14 possible preangioplasty and periangioplasty clinical and angiographic variables selected reversible perfusion defect on the thallium-201 scintigram on day 1 (p = 0.016) and immediate postangioplasty residual coronary narrowing (p = 0.004) as significant independent predictors of late restenosis, with younger patient age as an additional less powerful predictor (p less than 0.05). The findings have important implications regarding the pathogenesis of late coronary restenosis in patients undergoing successful angioplasty and they imply that in the majority of these patients pathophysiologic events in the early minutes and hours after angioplasty may determine the development of late restenosis

  15. Cardiac PET/CT for the diagnosis and prognostic evaluation of coronary artery disease

    International Nuclear Information System (INIS)

    Geronazzo, R.J.; Romero, R.L.; Campisi, R.

    2014-01-01

    Coronary artery disease is considered by de World Health Organization (WHO) to be pandemic. Eighty percent of the deaths occurs secondary to coronary artery disease, stroke and diabetes, thus they can be prevented. All of them are related to the same risk factors. Ischemic heart disease is the mayor cause of death in Argentina in the elderly population. Primary prevention strategies are essential in the health system. Hence, image complementary methods are very important to accomplish risk stratification, secondary prevention and pre-surgical evaluation. Nuclear cardiology has occupied this place through myocardial perfusion studies with radiopharmaceuticals, using SPECT (Single photon emission computed tomography) that have improved the level of sensitivity and specificity with ECG gated. Furthermore, positron emission tomography (PET) can evaluate relative myocardial perfusion, quantify absolute myocardial blood flow and coronary flow reserve. With its capacity to quantify rest-peak stress left ventricular systolic function we can underscore for example “balance ischemia”. By using hybrid PET/CT, also we can get information of coronary artery calcium scoring and coronary angiography. Currently, with the available softwares, we can acquire images in List mode. It means, from a single acquisition, it allows multiple image reconstructions, along with the associated electrocardiographic phase. PET/CT uses radiopharmaceuticals with short physical half life, and in conjunction with the possibility of acquiring in 3D mode, the perfusion studies can be done in a short time and offers lower radiation exposure to the patient. The new softwares for routine correction of misalignments between transmission and emission images have helped to reduce the frequency of artifacts and improve diagnostic accuracy. Hybrid PET/CT technology allows functional evaluation of myocardial perfusion combined with anatomic characterization of the epicardial coronary arteries, thereby

  16. Diagnostic and prognostic role of myocardial perfusion scintigraphy in kidney transplant candidates: narrative review

    Directory of Open Access Journals (Sweden)

    Alberto Bestetti

    2016-10-01

    Full Text Available PurposeCardiac screening in adult kidney transplant candidates with myocardial perfusion scintigraphy (MPS can reveal findings associated with increased risk for coronary heart disease events, but the exact value of this screening test is still undetermined.MethodsNarrative review based on the available literature and guidelines on the yield, benefits, and harms of MPS screening in kidney transplant candidates.ResultsAlthough coronary angiography carries low risk in general population, it is not without risk particularly in patients with complex comorbid disease and the use of intravenous contrast media may precipitate a need for hospitalization and death. We could avoid invasive coronary angiography in patients with chronic kidney disease, although with high coronary calcium score, but good left ventricle function and normal perfusion, evaluated by Gated single-photon emission computed tomographic (SPECT MPS. In fact, although Gated SPECT MPS has not a high sensitivity, it provides some variables that are closely related to sudden death: post-stress and rest-ejection fraction and left ventricular volumes, left ventricle muscle mass, extent of ischemia and scar.ConclusionsGated SPECT MPS is a valid noninvasive cardiac screening test. It can be used as alternative to stress echocardiography in kidney transplant candidates with high cardiovascular risk and a positive or inconclusive exercise tolerance ECG test.Patients with abnormal perfusion and cardiac dysfunction should undergo invasive coronary artery imaging and endovascular treatment, while angiography could be avoided in patients with normal MPI, having good long-term prognosis.

  17. [The absence of risk factors for coronary disease in Yanomami Indians and the influence of acculturation on arterial pressure].

    Science.gov (United States)

    Mancilha-Carvalho, J J; Carvalho, J V; Lima, J A; Sousa e Silva, N A

    1992-10-01

    To investigate the hypothesis that hypertension and coronary heart disease are "civilization diseases", analyzing the distribution of their antecedents in an Indian population and observing the influence of acculturation on blood pressure. Seven hundred and twenty-five Yanomami Indians of both sexes, ages above 14 years, inhabitants of eight villages in Roraima and Amazonas states were examined. Measures related to all classical coronary risk factors were carried out and urine samples were collected to measure electrolytes. None of the known coronary risk factors were found. The blood pressure levels were low and did not increase with increasing age. There was influence of acculturation on blood pressure and it was in part mediated by increase in body weight and sodium intake. The absence of hypertension and other coronary risk factors and the increase of blood pressure with acculturation, among an isolated population, strongly suggest that these diseases are "civilization diseases".

  18. Effect of perfusion and irrigation flow rate variations on NaCl efflux from the isolated, perfused head of the marine teleost, Myoxocephalus octodecimspinosus

    Energy Technology Data Exchange (ETDEWEB)

    Claiborne, J.B. (Miami Univ., Coral Gables, FL (USA)); Evans, D.H. (Mt. Desert Island Biological Laboratory, Salsbury Cove, ME, USA)

    1981-06-01

    In vivo branchial blood pressure and unidirectional efflux values for NaCl were determined in the marine teleost, Myoxocephalus octodecimspinosus. Utilizing an isolated, perfused head preparation, perfused at in vivo pressure levels, NaCl efflux was measured and compared to in vivo values. The effect of variations in perfusion or irrigation rates on the ion efflux across the gills of the isolated head was also studied. The efflux of /sup 22/Na from the isolated, perfused head was found to be similar to in vivo values and dependent on perfusion flow and pressure. In vitro /sup 36/Cl efflux was lower than the efflux from intact animals and was determined to be flow/pressure independent. Irrigation rate changes at all rates tested did not affect the unidirectional efflux of either ion.

  19. Prognostic Value of Quantitative Stress Perfusion Cardiac Magnetic Resonance.

    Science.gov (United States)

    Sammut, Eva C; Villa, Adriana D M; Di Giovine, Gabriella; Dancy, Luke; Bosio, Filippo; Gibbs, Thomas; Jeyabraba, Swarna; Schwenke, Susanne; Williams, Steven E; Marber, Michael; Alfakih, Khaled; Ismail, Tevfik F; Razavi, Reza; Chiribiri, Amedeo

    2018-05-01

    This study sought to evaluate the prognostic usefulness of visual and quantitative perfusion cardiac magnetic resonance (CMR) ischemic burden in an unselected group of patients and to assess the validity of consensus-based ischemic burden thresholds extrapolated from nuclear studies. There are limited data on the prognostic value of assessing myocardial ischemic burden by CMR, and there are none using quantitative perfusion analysis. Patients with suspected coronary artery disease referred for adenosine-stress perfusion CMR were included (n = 395; 70% male; age 58 ± 13 years). The primary endpoint was a composite of cardiovascular death, nonfatal myocardial infarction, aborted sudden death, and revascularization after 90 days. Perfusion scans were assessed visually and with quantitative analysis. Cross-validated Cox regression analysis and net reclassification improvement were used to assess the incremental prognostic value of visual or quantitative perfusion analysis over a baseline clinical model, initially as continuous covariates, then using accepted thresholds of ≥2 segments or ≥10% myocardium. After a median 460 days (interquartile range: 190 to 869 days) follow-up, 52 patients reached the primary endpoint. At 2 years, the addition of ischemic burden was found to increase prognostic value over a baseline model of age, sex, and late gadolinium enhancement (baseline model area under the curve [AUC]: 0.75; visual AUC: 0.84; quantitative AUC: 0.85). Dichotomized quantitative ischemic burden performed better than visual assessment (net reclassification improvement 0.043 vs. 0.003 against baseline model). This study was the first to address the prognostic benefit of quantitative analysis of perfusion CMR and to support the use of consensus-based ischemic burden thresholds by perfusion CMR for prognostic evaluation of patients with suspected coronary artery disease. Quantitative analysis provided incremental prognostic value to visual assessment and

  20. Role of stress myocardial perfusion SPECT scan in detection and management of coronary artery disease: Nairobi experience

    International Nuclear Information System (INIS)

    Makhdomi, K.B.; Warshow, M.M.; Patel, P.K.J.; Shah, D.; Githegi, D.R.M.

    2002-01-01

    Aim: Stress myocardial perfusion scans have acquired a significant role in the detection and management of Coronary Artery Disease. However, this mode of investigation has only recently been available in Nairobi, and this is the first such study from East Africa. We undertook a comparison of our results with that in the literature, to see whether they conformed to it. Materials and Methods: We performed a review of our initial 82 evaluable studies. The scans were performed with 99mTc-Tetrofosmin, using the single day stress-rest protocol with SPECT acquisitions. We carried out a correlation of our scan findings with angiographic data (where available), and clinical follow-up. The clinical end points where furnished by the referring physicians. We focused on myocardial infarction, need for re-vascularisation, and death. The mean clinical follow-up was 21.8 months (range of 12 months to 39 months). Results: Eighty (98%) of the studies revealed concordance with angiographic findings and/or were predictive of clinical outcome. Two studies were discordant, and will be discussed. The results are comparable with those in the literature. Conclusion: It is concluded that stress myocardial perfusion studies, done at our Centre, had a good predictive value, with regards to the presence and severity of disease, and correlated with the clinical outcome data

  1. Skin perfusion pressure as an indicator of tissue perfusion in valvular heart surgery: Preliminary results from a prospective, observational study.

    Directory of Open Access Journals (Sweden)

    Young Song

    Full Text Available Hemodynamic management aims to provide adequate tissue perfusion, which is often altered during cardiac surgery with cardiopulmonary bypass (CPB. We evaluated whether skin perfusion pressure (SPP can be used for monitoring of adequacy of tissue perfusion in patients undergoing valvular heart surgery. Seventy-two patients undergoing valve replacement were enrolled. SPP and serum lactate level were assessed after anaesthesia induction (baseline, during CPB, after CPB-off, end of surgery, arrival at intensive care unit, and postoperative 6 h. Lactate was further measured until postoperative 48 h. Association of SPP with lactate and 30-day morbidity comprising myocardial infarction, acute kidney injury, stroke, prolonged intubation, sternal infection, reoperation, and mortality was assessed. Among the lactate levels, postoperative 6 h peak value was most closely linked to composite of 30-day morbidity. The SPP value during CPB and its % change from the baseline value were significantly associated with the postoperative 6 h peak lactate (r = -0.26, P = 0.030 and r = 0.47, P = 0.001, respectively. Optimal cut-off of % decrease in SPP during CPB from baseline value for the postoperative 6 h hyperlactatemia was 48% (area under curve, 0.808; 95% confidence interval (CI, 0.652-0.963; P = 0.001. Decrease in SPP >48% during CPB from baseline value was associated with a 12.8-fold increased risk of composite endpoint of 30-day morbidity (95% CI, 1.48-111.42; P = 0.021 on multivariate logistic regression. Large decrease in SPP during CPB predicts postoperative 6 h hyperlactatemia and 30-day morbidity, which implicates a promising role of SPP monitoring in the achievement of optimal perfusion during CPB.

  2. Skin perfusion pressure as an indicator of tissue perfusion in valvular heart surgery: Preliminary results from a prospective, observational study.

    Science.gov (United States)

    Song, Young; Soh, Sarah; Shim, Jae-Kwang; Park, Kyoung-Un; Kwak, Young-Lan

    2017-01-01

    Hemodynamic management aims to provide adequate tissue perfusion, which is often altered during cardiac surgery with cardiopulmonary bypass (CPB). We evaluated whether skin perfusion pressure (SPP) can be used for monitoring of adequacy of tissue perfusion in patients undergoing valvular heart surgery. Seventy-two patients undergoing valve replacement were enrolled. SPP and serum lactate level were assessed after anaesthesia induction (baseline), during CPB, after CPB-off, end of surgery, arrival at intensive care unit, and postoperative 6 h. Lactate was further measured until postoperative 48 h. Association of SPP with lactate and 30-day morbidity comprising myocardial infarction, acute kidney injury, stroke, prolonged intubation, sternal infection, reoperation, and mortality was assessed. Among the lactate levels, postoperative 6 h peak value was most closely linked to composite of 30-day morbidity. The SPP value during CPB and its % change from the baseline value were significantly associated with the postoperative 6 h peak lactate (r = -0.26, P = 0.030 and r = 0.47, P = 0.001, respectively). Optimal cut-off of % decrease in SPP during CPB from baseline value for the postoperative 6 h hyperlactatemia was 48% (area under curve, 0.808; 95% confidence interval (CI), 0.652-0.963; P = 0.001). Decrease in SPP >48% during CPB from baseline value was associated with a 12.8-fold increased risk of composite endpoint of 30-day morbidity (95% CI, 1.48-111.42; P = 0.021) on multivariate logistic regression. Large decrease in SPP during CPB predicts postoperative 6 h hyperlactatemia and 30-day morbidity, which implicates a promising role of SPP monitoring in the achievement of optimal perfusion during CPB.

  3. A clinical study of thallium-201 scintigraphy in hypertensive patients with and without left ventricular hypertrophy

    International Nuclear Information System (INIS)

    Ouyang Wei; He Guorong; Liu Jinhua; Huang Yuying; Qian Xuexian

    2001-01-01

    Objective: Based on coronary angiography, thallium-201 myocardial scintigraphy was evaluated in hypertensive patients with and without left ventricular hypertrophy, and the causes of its perfusion abnormalities were discussed. Methods: Thallium-201 myocardial scintigraphy was performed on 85 patients with clinically suspected coronary artery disease. Coronary angiography was performed on patients with perfusion abnormalities in one month after scintigraphy. Results: The rate of 201 Tl perfusion abnormalities in hypertensive patients with hypertrophy (85.7%) was higher than normal blood pressure (39.3%, P 201 Tl perfusion abnormalities occur in hypertensive patients with hypertrophy. The perfusion abnormalities may be caused not only by coronary large vessel disease, but also by coronary microvascular disease

  4. Relationship Between Adenosine - Induced ST Segment Depression During 99mTc-MIBI Scintigraphy and The Severity of Coronary Artery Disease

    International Nuclear Information System (INIS)

    Cho, Jung Ah; Choi, Jung Il; Kwak, Dong Suk

    1994-01-01

    Pharmacologic coronary vasodilation in conjunction with myocardial perfusion scintigraphy has become an alternative to dynamic exercise test for the diagnosis and risk stratification of coronary artery disease, especially in patients who are unable to perform adequate exercise. Dipyridamole and adenosine have been used for pharmacologic stress testing with myocardial perfusion imaging. Adenosine is a potent, coronary vasodilator with rapid onset of action, short half life, near maximal coronary vasodilation and less serious side effects. ST segment depression has been reported in about 7-15% of patients with coronary artery disease receiving dipyridamole in conjunction with myocardial perfusion imaging. The exact cause and clinical significance are not known. In order to evaluate the relationship between adenosine-induced ST segment depression during 99m Tc-MIBI myocardial perfusion scintigraphy and the severity of coronary artery disease, we performed 99m -MIBI imaging after intravenous infusion of adenosine in 120 patients with suspected coronary artery disease. Of the 120 patients, 28 also performed coronary angiography. There were 24 patients with ST segment depression during 99m Tc-MIIBI scintigraphy and 96 patients without ST segment depression. Adenosine was infused intravenously at a dose of 0.14 mg/kg per minute for 6 minutes and 99 MmTc-MIB1 was injected at 3 minute. We then compared the hemodynamic changes, side effects, scintigraphic and angiographic findings. Heart rate increased 90 ± 19 beats/minute in the group with ST depression compared with 80 ±16 beats/minute in the group without ST depression(p 9m Tc-MIBI images were abnormal in 23(96%) patients with ST segment depression and 66(69%) patients without ST segment depression(p 99m Tc-MIBI myocardial perfusion scintigraphy with intravenous adenosine is related to the severity of coronary artery disease.

  5. Normal value of functional parameters in gated myocardial perfusion SPECT in patients with low risk of coronary artery disease: emory cardiac tool box program

    Energy Technology Data Exchange (ETDEWEB)

    Kang, D. Y.; Kim, M. H.; Kim, Y. D.; Kim, D. K. [Donga University College of Medicine, Busan (Korea, Republic of)

    2002-07-01

    Absolute value of the functional data of gated myocardial perfusion SPECT is necessary to determine that individual patient is normal or not. Tc-99m MIBI gated myocardial perfusion SPECT was performed using emory cardiac tool box program. All patients (M:F=15:36, age 64{+-}10 yrs) showed normal myocardial perfusion. The patients with following characteristics were excluded; previous angina or MI, ECG change with Q wave or ST-T change, diabetes mellitus, hypercholesterolemia, typical chest pain and hypertension. In all patients, myocardial mass is 117{+-}23 g in stress gated SPECT, 106{+-}22 g in stress ungated SPECT and 102{+-}21 g in rest ungated SPECT. EDV is 90{+-}28 ml, ESV 26{+-}20 ml, SV 66{+-}21 ml, EF 73{+-}10 % and TID 1.06{+-}0.14. Myocardial mass in rest ungated SPECT is significantly different between men and women (p=0.025). Myocardial mass is significantly different between stress gated SPECT and stress ungated SPECT (p=0.000), and between stress ungated SPECT and rest ungated SPECT (p=0.003). We provide normal value of functional parameters to determine the abnormality of individual patients in patients with low risk of coronary artery disease.

  6. Coronary Physiology During Exercise and Vasodilation in the Healthy Heart and in Severe Aortic Stenosis.

    Science.gov (United States)

    Lumley, Matthew; Williams, Rupert; Asrress, Kaleab N; Arri, Satpal; Briceno, Natalia; Ellis, Howard; Rajani, Ronak; Siebes, Maria; Piek, Jan J; Clapp, Brian; Redwood, Simon R; Marber, Michael S; Chambers, John B; Perera, Divaka

    2016-08-16

    Severe aortic stenosis (AS) can manifest as exertional angina even in the presence of unobstructed coronary arteries. The authors describe coronary physiological changes during exercise and hyperemia in the healthy heart and in patients with severe AS. Simultaneous intracoronary pressure and flow velocity recordings were made in unobstructed coronary arteries of 22 patients with severe AS (mean effective orifice area 0.7 cm(2)) and 38 controls, at rest, during supine bicycle exercise, and during hyperemia. Stress echocardiography was performed to estimate myocardial work. Wave intensity analysis was used to quantify waves that accelerate and decelerate coronary blood flow (CBF). Despite a greater myocardial workload in AS patients compared with controls at rest (12,721 vs. 9,707 mm Hg/min(-1); p = 0.003) and during exercise (27,467 vs. 20,841 mm Hg/min(-1); p = 0.02), CBF was similar in both groups. Hyperemic CBF was less in AS compared with controls (2,170 vs. 2,716 cm/min(-1); p = 0.05). Diastolic time fraction was greater in AS compared with controls, but minimum microvascular resistance was similar. With exercise and hyperemia, efficiency of perfusion improved in the healthy heart, demonstrated by an increase in the relative contribution of accelerating waves. By contrast, in AS, perfusion efficiency decreased due to augmentation of early systolic deceleration and an attenuated rise in systolic acceleration waves. Invasive coronary physiological evaluation can be safely performed during exercise and hyperemia in patients with severe aortic stenosis. Ischemia in AS is not related to microvascular disease; rather, it is driven by abnormal cardiac-coronary coupling. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  7. Direct myocardial perfusion imaging in valvular heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Soto, R.C.; Durante, M.L.; Villacorta, E.V.; Torres, J.F.; Monzon, O.P.

    1981-02-01

    Twenty two patients with rheumatic valvular heart disease - 21 having a history of heart failure - were studied using direct coronary injection of /sup 99m/Tc labelled MAA particles during the course of hemodynamic and arteriographic studies. Myocardial perfusion deficit patterns have been shown to be consistent or indicative of either patchy, regional or gross ischemia. In patients with history of documented heart failure 90% (18 cases) had ischemic perfusion deficit in the involved ventricle. We conclude that diminished myocardial blood flow is an important mechanism contributing to the development of heart failure.

  8. Direct myocardial perfusion imaging in valvular heart disease

    International Nuclear Information System (INIS)

    Soto, R.C.; Durante, M.L.; Villacorta, E.V.; Torres, J.F.; Monzon, O.P.

    1981-01-01

    Twenty two patients with rheumatic valvular heart disease - 21 having a history of heart failure - were studied using direct coronary injection of sup(99m)Tc labelled MAA particles during the course of hemodynamic and arteriographic studies. Myocardial perfusion deficit patterns have been shown to be consistent or indicative of either patchy, regional or gross ischemia. In patients with history of documented heart failure 90% (18 cases) had ischemic perfusion deficit in the involved ventricle. We conclude that diminished myocardial blood flow is an important mechanism contributing to the development of heart failure. (orig.) [de

  9. SU-C-201-04: Quantification of Perfusion Heterogeneity Based On Texture Analysis for Fully Automatic Detection of Ischemic Deficits From Myocardial Perfusion Imaging

    International Nuclear Information System (INIS)

    Fang, Y; Huang, H; Su, T

    2015-01-01

    Purpose: Texture-based quantification of image heterogeneity has been a popular topic for imaging studies in recent years. As previous studies mainly focus on oncological applications, we report our recent efforts of applying such techniques on cardiac perfusion imaging. A fully automated procedure has been developed to perform texture analysis for measuring the image heterogeneity. Clinical data were used to evaluate the preliminary performance of such methods. Methods: Myocardial perfusion images of Thallium-201 scans were collected from 293 patients with suspected coronary artery disease. Each subject underwent a Tl-201 scan and a percutaneous coronary intervention (PCI) within three months. The PCI Result was used as the gold standard of coronary ischemia of more than 70% stenosis. Each Tl-201 scan was spatially normalized to an image template for fully automatic segmentation of the LV. The segmented voxel intensities were then carried into the texture analysis with our open-source software Chang Gung Image Texture Analysis toolbox (CGITA). To evaluate the clinical performance of the image heterogeneity for detecting the coronary stenosis, receiver operating characteristic (ROC) analysis was used to compute the overall accuracy, sensitivity and specificity as well as the area under curve (AUC). Those indices were compared to those obtained from the commercially available semi-automatic software QPS. Results: With the fully automatic procedure to quantify heterogeneity from Tl-201 scans, we were able to achieve a good discrimination with good accuracy (74%), sensitivity (73%), specificity (77%) and AUC of 0.82. Such performance is similar to those obtained from the semi-automatic QPS software that gives a sensitivity of 71% and specificity of 77%. Conclusion: Based on fully automatic procedures of data processing, our preliminary data indicate that the image heterogeneity of myocardial perfusion imaging can provide useful information for automatic determination

  10. Study of Coronary Flow Reserve with Intravenous Use of Microbubbles (Contrast Echocardiography and Adenosine: Protocol for Clinical Application in Patients Suspected of Having Coronary Heart Disease

    Directory of Open Access Journals (Sweden)

    Morcerf Fernando

    2002-01-01

    Full Text Available OBJECTIVE: To test the feasibility, safety and accuracy of the adenosine protocol in the study of myocardial perfusion with microbubbles contrast echocardiography. METHODS: 81 pts (64 male, 60+11 years were submitted to contrast echocardiography with PESDA (sonicated solution of albumin 20%-1ml, dextrose 5%-12ml and deca-fluorobutane gas-8ml to study the myocardial perfusion at rest and after bolus injection of adenosine (6 to 18mg and to coronary angiography within 1 month each other. For each patient 3 left ventricle perfusion beds were considered (total of 243 territories. 208 territories were analyzed and 35 territories were excluded. PESDA was continuously infused (1-2ml/min, titrated for best myocardial contrast. Triggered (1:1 second harmonic imaging was used. RESULTS: Coronary angiography showed 70 flow limiting (> 75% lesions and 138 no flow limiting lesions. At rest an obvious myocardium contrast enhancement was seen in at least 1 segment of a territory in all patients. After adenosine injection an unquestionable further increase in myocardial contrast was observed in 136 territories (99% related to no flow limiting lesions, lasting < 10 s, and a myocardial perfusion defect was detected in 68 territories (97% related to flow limiting lesions. It was observed only 4 false results. There were no serious complications. CONCLUSION: Myocardial perfusion study with PESDA and adenosine protocol is a practical, safe and accurate method to analyze the coronary flow reserve.

  11. [An automatic system controlled by microcontroller for carotid sinus perfusion].

    Science.gov (United States)

    Yi, X L; Wang, M Y; Fan, Z Z; He, R R

    2001-08-01

    To establish a new method for controlling automatically the carotid perfusion pressure. A cheap practical automatic perfusion unit based on AT89C2051 micro controller was designed. The unit, LDB-M perfusion pump and the carotid sinus of an animal constituted an automatic perfusion system. This system was able to provide ramp and stepwise updown perfusion pattern and has been used in the research of baroreflex. It can insure the precision and reproducibility of perfusion pressure curve, and improve the technical level in corresponding medical field.

  12. Myocardial blood flow quantification for evaluation of coronary artery disease by positron emission tomography, cardiac magnetic resonance imaging, and computed tomography.

    Science.gov (United States)

    Waller, Alfonso H; Blankstein, Ron; Kwong, Raymond Y; Di Carli, Marcelo F

    2014-05-01

    The noninvasive detection of the presence and functional significance of coronary artery stenosis is important in the diagnosis, risk assessment, and management of patients with known or suspected coronary artery disease. Quantitative assessment of myocardial perfusion can provide an objective and reproducible estimate of myocardial ischemia and risk prediction. Positron emission tomography, cardiac magnetic resonance, and cardiac computed tomography perfusion are modalities capable of measuring myocardial blood flow and coronary flow reserve. In this review, we will discuss the technical aspects of quantitative myocardial perfusion imaging with positron emission tomography, cardiac magnetic resonance imaging, and computed tomography, and its emerging clinical applications.

  13. The effect of perfusion and irrigation flow rate variations on NaCl efflux from the isolated, perfused head of the marine teleost, Myoxocephalus octodecimspinosus

    International Nuclear Information System (INIS)

    Claiborne, J.B.; Evans, D.H.

    1981-01-01

    In vivo branchial blood pressure and unidirectional efflux values for NaCl were determined in the marine teleost, Myoxocephalus octodecimspinosus. Utilizing an isolated, perfused head preparation, perfused at in vivo pressure levels, NaCl efflux was measured and compared to in vivo values. The effect of variations in perfusion or irrigation rates on the ion efflux across the gills of the isolated head was also studied. The efflux of 22 Na from the isolated, perfused head was found to be similar to in vivo values and dependent on perfusion flow and pressure. In vitro 36 Cl efflux was lower than the efflux from intact animals and was determined to be flow/pressure independent. Irrigation rate changes at all rates tested did not affect the unidirectional efflux of either ion. (Auth.)

  14. Study of a new method for the evaluation of portal vein pressure by hepatic perfusion imaging

    International Nuclear Information System (INIS)

    Cheng Muhua; Ling Yunbiao; Pan Zhiheng; Zhang Feng; Chen Weizhen

    2002-01-01

    To study a new method for predication of portal vein pressure (PVP) by hepatic perfusion imaging. 25 hepato-cirrhotic cases and 13 normal controls were performed the hepatic perfusion imaging. According to two compartmental model the values of portal vein indexes (PVI) was calculated using curve slope, area and hepatic heart perfusion ratio methods etc. The relationship of PVI with different method to PVP was also observed. All PVI by three methods in hepatocirrhosis were higher than those in normal controls (P<0.01), and also positively correlated with the PVP, their correlated coefficients was 0.79, 0.60, 0.68 respectively. Among them the slope method was most markedly significant than normal control and closely correlated with PVP. PVI can sensitively reflect the changes of portal vein blood flow. And it was an atraumatic, simple method for the evaluation of PVP

  15. Comparison of adenosine and exercise stress 201Tl myocardial perfusion imaging for diagnosing coronary heart disease in women

    International Nuclear Information System (INIS)

    Li Jiangjin; Ma Shuren; Meng Tao; Bao Zhi; Cui Jianhe

    2011-01-01

    Objective: To compare the diagnostic value of adenosine and exercise stress myocardial perfusion imaging (MPI) for detecting coronary heart disease (CHD) in women. Methods: One hundred and thirty-eight patients with CHD were randomly divided into two groups: adenosine stress group (n=69)and exercise stress group (n=69). All patients underwent myocardial SPECT evaluation. Coronary angiography (CAG), referred as 'gold standard' , was performed in each patient within 1 week before or after MPI. The diagnostic value of the two stress MPI was compared with χ 2 test or Fisher's exact test. Results: In adenosine stress group, the sensitivity, negative predictive value and accuracy were 88.2% (45/51), 72.7% (16/22), 88.4% (61/69), respectively, which were not significantly different from those of the exercise stress group (91.7% (44/48), 66.7% (8/12), 81.2% (52/64); χ 2 =0.571, 0.714, 0.249, P>0.05). However, the false positive rate of adenosine stress (11.1%, 2/18) was significantly lower than that of exercise stress (50.0%, 8/16), P=0.023. Conclusions: Adenosine and exercise stress MPI have similar value for CHD diagnosis in women, however, adenosine stress MPI may have an advantage of low false positive rate. (authors)

  16. Imaging techniques in the diagnosis of coronary heart disease

    International Nuclear Information System (INIS)

    Frank, H.

    1997-01-01

    Coronary heart disease is the leading cause of death and disability worldwide. Coronary angiography makes it possible to visualize coronary artery stenosis and can be used for angioplasty and stent implantation; however, it does not allow the assessment of changes in myocardial microcirculation. The severity of an angiographically evaluated coronary stenosis does not always correspond to the extent of myocardial ischemia. Nonivasive techniques are needed to reexamine our reliance on coronary angiography and to explore the clinical value fo the physiological assessment of coronary artery stenoses. Such noninvasive techniques might become important tools in the future following an overal evaluation of coronary morphology, myocardial function and perfusion ascertained by all available methods. (orig.) [de

  17. Assessment of coronary artery disease with nicorandil stress magnetic resonance imaging

    International Nuclear Information System (INIS)

    Kawase, Yoshio; Nichimoto, Masaki; Hato, Katsunori; Okajima, Kazue; Yoshikawa, Junichi

    2004-01-01

    Although dipyridamole and adenosine have been used as vasodilator agents, we believe they are inadequate for vasodilator perfusion magnetic resonance imaging, due to adverse effects (flushing, warmth, headaches, and arrhythmia). Nicorandil, a potassium channel opener, has been reported to increase coronary blood flow and it was associated with fewer adverse effects than adenosine or dipiridamole. We set out to investigate whether the coronary artery stenosis could be assessed by nicorandil stress perfusion magnetic resonance imaging. First-pass contrast-enhanced magnetic resonance images of the left ventricle acquired from 50 patients at rest and during intravenous administration of nicorandil using multi-slice turbo field echo with multi shot echo-planar-imaging. Coronary angiography was performed within 1 week. There was no adverse effects during nicorandil stress in any patients. The overall sensitivity and specificity of magnetic resonance imaging in identifying patients with significant stenosis of at least one coronary artery were 93.9% (31 of 33 patients) and 94.1% (16 of 17 patients), respectively. The sensitivity of magnetic resonance imaging for detecting significant stenosis in the left anterior descending artery was 87.5%; the sensitivity in the left circumflex artery was 80%; the sensitivity in the right coronary artery was 92.3%. Similar sensitivities were observed for all 3 vascular regions, indicating that all myocardial segments were visualized with similar image quality. The present study shows that nicorandil stress perfusion magnetic resonance imaging is a safe, feasible technique for assessing coronary artery stenosis severity in a totally-noninvasive manner. (authors)

  18. Diagnostic performance of stress myocardial perfusion imaging for coronary artery disease: a systematic review and meta-analysis

    International Nuclear Information System (INIS)

    Jong, Marcus C. de; Genders, Tessa S.S.; Geuns, Robert-Jan van; Moelker, Adriaan; Hunink, M.G.M.

    2012-01-01

    To determine and compare the diagnostic performance of stress myocardial perfusion imaging (MPI) for the diagnosis of obstructive coronary artery disease (CAD), using conventional coronary angiography (CCA) as the reference standard. We searched Medline and Embase for literature that evaluated stress MPI for the diagnosis of obstructive CAD using magnetic resonance imaging (MRI), contrast-enhanced echocardiography (ECHO), single-photon emission computed tomography (SPECT) and positron emission tomography (PET). All pooled analyses were based on random effects models. Articles on MRI yielded a total of 2,970 patients from 28 studies, articles on ECHO yielded a sample size of 795 from 10 studies, articles on SPECT yielded 1,323 from 13 studies. For CAD defined as either at least 50 %, at least 70 % or at least 75 % lumen diameter reduction on CCA, the natural logarithms of the diagnostic odds ratio (lnDOR) for MRI (3.63; 95 % CI 3.26-4.00) was significantly higher compared to that of SPECT (2.76; 95 % CI 2.28-3.25; P = 0.006) and that of ECHO (2.83; 95 % CI 2.29-3.37; P = 0.02). There was no significant difference between the lnDOR of SPECT and ECHO (P = 0.52). Our results suggest that MRI is superior for the diagnosis of obstructive CAD compared with ECHO and SPECT. ECHO and SPECT demonstrated similar diagnostic performance. (orig.)

  19. The Groningen hypothermic liver perfusion pump : Functional evaluation of a new machine perfusion system

    NARCIS (Netherlands)

    van der Plaats, A.; Maathuis, M. H. J.; Hart, N. A. 't; Bellekom, A. A.; Hofker, H. S.; van der Houwen, E. B.; Verkerke, G. J.; Leuvenink, H. G. D.; Verdonck, P.; Ploeg, R. J.; Rakhorst, G.

    2006-01-01

    To improve preservation of donor livers, we have developed a portable hypothermic machine perfusion (HMP) system as an alternative for static cold storage. A prototype of the system was built and evaluated on functionality. Evaluation criteria included 24 h of adequate pressure controlled perfusion,

  20. Effects of isosorbide dinitrate on exertion-induced anomalous myocardial perfusion in coronary diseases studied with the aid of 201Th scintiscanning

    International Nuclear Information System (INIS)

    Wolf, R.; Pretschner, P.; Engel, H.J.; Hundeshagen, H.; Lichtlen, P.R.; Medizinische Hochschule Hannover

    1979-01-01

    The effect of isosorbide dinitrate (ISDN) (10 mg sublingually) on myocardial perfusion under ischemic conditions was analyzed in 14 patients with angiographically severe coronary artery disease and typical angina pectoris, using 201-thallium-myocardial scintiscanning. All patients underwent two identical scintiscans with the same work load during bicycle ergometry; a control scintiscan leading to angina and ST-depressions of > 0.1 mV was followed 4-6 weeks later by a scintiscan after ISDN; all drugs - except sublingual nitroglycerin - were withheld for an entire week. - Results: 25 of 39 new or enlarged, exercise-induced defects (64%) were normalized after ISDN; 14 new or enlarged defects remained unchanged (p [de

  1. Preserved regulation of renal perfusion pressure by small and intermediate conductance K-Ca channels in hypertensive mice with or without renal failure

    DEFF Research Database (Denmark)

    Waeckel, L.; Bertin, F.; Clavreul, N.

    2015-01-01

    -transgenic female mice expressing human angiotensinogen and renin (AR) genes received either control or a high-salt diet associated to a nitric oxide (NO) synthase inhibitor treatment (BLSL and ARSL). Changes in renal perfusion pressure (RPP) were measured in isolated perfused kidneys. BLSL and AR were moderately...

  2. Anomalous origin of the left coronary artery from the pulmonary artery with patent ductus arteriosus: a must to recognize entity.

    Science.gov (United States)

    Awasthy, Neeraj; Marwah, Ashutosh; Sharma, Rajesh; Dalvi, Bharat

    2010-09-01

    Anomalous left coronary artery from the pulmonary trunk (ALCAPA) presents in early infancy with a clinical picture of congestive heart failure with left ventricular (LV) dysfunction and mitral insufficiency. These manifestations of myocardial ischaemia may be masked in the presence of an associated patent ductus arteriosus (PDA) or ventricular septal defect (VSD) which prevents the fall of pulmonary artery pressures and allows perfusion of the anomalous coronary artery. We present a case of a patient with large PDA-associated ALCAPA and preserved LV function. The importance of such a finding lies in the fact that VSD closure or PDA ligation in such cases would unmask the ALCAPA.

  3. Initial multicentre experience of high-speed myocardial perfusion imaging: comparison between high-speed and conventional single-photon emission computed tomography with angiographic validation

    Energy Technology Data Exchange (ETDEWEB)

    Neill, Johanne [University College London Hospital, Institute of Nuclear Medicine, London (United Kingdom); The Prince Charles Hospital, Brisbane (Australia); Prvulovich, Elizabeth M.; Bomanji, Jamshed B. [University College London Hospital, Institute of Nuclear Medicine, London (United Kingdom); Fish, Matthews B. [Sacred Heart Medical Center (SHMC), Springfield, OR (United States); Berman, Daniel S.; Slomka, Piotr J. [Cedars-Sinai Medical Center, Los Angeles, CA (United States); Sharir, Tali [Procardia Maccabi Healthcare Services (PMHS), Tel Aviv (Israel); Martin, William H. [Vanderbilt University Medical Center (VUMC), Nashville, TN (United States); DiCarli, Marcelo F. [Brigham and Women' s Hospital (BWH), Boston, MA (United States); Ziffer, Jack A. [Baptist Hospital of Miami (BHM), Miami, FL (United States); Shiti, Dalia [Spectrum-Dynamics, Caesarea (Israel); Ben-Haim, Simona [University College London Hospital, Institute of Nuclear Medicine, London (United Kingdom); Chaim Sheba Medical Center, Department of Nuclear Medicine, Tel-Hashomer (Israel)

    2013-07-15

    High-speed (HS) single-photon emission computed tomography (SPECT) with a recently developed solid-state camera shows comparable myocardial perfusion abnormalities to those seen in conventional SPECT. We aimed to compare HS and conventional SPECT images from multiple centres with coronary angiographic findings. The study included 50 patients who had sequential conventional SPECT and HS SPECT myocardial perfusion studies and coronary angiography within 3 months. Stress and rest perfusion images were visually analysed and scored semiquantitatively using a 17-segment model by two experienced blinded readers. Global and coronary territorial summed stress scores (SSS) and summed rest scores (SRS) were calculated. Global SSS {>=}3 or coronary territorial SSS {>=}2 was considered abnormal. In addition the total perfusion deficit (TPD) was automatically derived. TPD >5 % and coronary territorial TPD {>=}3 % were defined as abnormal. Coronary angiograms were analysed for site and severity of coronary stenosis; {>=}50 % was considered significant. Of the 50 patients, 13 (26 %) had no stenosis, 22 (44 %) had single-vessel disease, 6 (12 %) had double-vessel disease and 9 (18 %) had triple-vessel disease. There was a good linear correlation between the visual global SSS and SRS (Spearman's {rho} 0.897 and 0.866, respectively; p < 0.001). In relation to coronary angiography, the sensitivities, specificities and accuracies of HS SPECT and conventional SPECT by visual assessment were 92 % (35/38), 83 % (10/12) and 90 % (45/50) vs. 84 % (32/38), 50 % (6/12) and 76 % (38/50), respectively (p < 0.001). The sensitivities, specificities and accuracies of HS SPECT and conventional SPECT in relation to automated TPD assessment were 89 % (31/35), 57 % (8/14) and 80 % (39/49) vs. 86 % (31/36), 77 % (10/13) and 84 % (41/49), respectively. HS SPECT allows fast acquisition of myocardial perfusion images that correlate well with angiographic findings with overall accuracy by visual

  4. Nuclear cardiology in acute coronary syndromes

    International Nuclear Information System (INIS)

    Bulow, H.; Schwaiger, M.

    2005-01-01

    Acute coronary syndromes are a frequent manifestation of a coronary artery disease, usually being associated with chest pain and presenting as a medical emergency. Since a considerable number of patients with chest pain, however, have a non cardiac etiology of trier pain, properly triaging these patients represents a diagnostic challenge for physicians in the emergency department. As the available diagnostic procedures have limited accuracy, many different diagnostic strategies have been evaluated. Among these, radionuclide myocardial perfusion imaging (MPI) at rest or in combination with stress procedures has been investigated in many trails. MPI has been proven to be useful, especially in a patient population with a low to intermediate probability of an ischemic event. Perfusion scintigraphy has a high sensitivity in the detection of myocardial infarction and reveals an excellent negative predictive value, allowing a safe discharge strategy of patients with a negative scan result. Moreover, it enables risk stratification and provides incremental and independent prognostic information regarding short to long term future cardiac adverse events. Several cost effectiveness studies have shown that perfusion imaging leads to lower overall direct costs, mainly by a reduction of unnecessary hospital admissions and diagnostic angiograms, without worsening of the clinical outcome of these patients. As a possible study endpoint, myocardial perfusion imaging in the acute setting enables the quantification of salvaged myocardium and therefore the evaluation of treatment efficacy. Besides perfusion agents, several infarcts avid radiopharmaceuticals have been developed, which in part show promising results. However, larger randomized trials evaluating these tracers in clinical settings are needed to warrant routine clinical application

  5. Exercise, stress or what. The non-invasive detection of latent coronary artery disease

    International Nuclear Information System (INIS)

    Coltart, J.; Robinson, P.S.

    1978-01-01

    This communication discusses the methods of detecting latent coronary artery disease in an entirely asymptomatic individual with no previous symptoms or signs suggestive of coronary artery disease. Isotope techniques are being increasingly employed in the detection and assessment of coronary artery disease in that they may enable the confirmation of the presence of ischaemia, the extent and location of the underlying coronary artery disease and the effect of ischaemia on overall and regional left ventricular function. Three groups of techniques are commonly employed: 1. assessment of myocardial perfusion; 2. labelling of acute myocardial infarction; 3. overall and regional left ventricular function studies. Isotopes of potassium were initially studied, and, despite technical problems with imaging, 43 K has proved a useful agent in that over a range of coronary flow rates from normal to severely reduced flow, myocardial uptake parallels myocardial blood flow. Myocardial perfusion imaging should enhance the sensitivity and specificity of exercise testing in the symptomatic population and should also be helpful in the asymptomatic population although data on such populations are as yet extremely limited. Acute infarct labelling has little relevance to the very early detection of coronary artery disease. Assessment of overall and regional left ventricular function using gated blood pool scanning at rest and possibly also during exercise has potentially very wide applications in ischaemic heart disease and in combination with myocardial perfusion scanning in the assessment of symptomatic ischaemic heart disease and the detection of ischaemia and coronary artery disease in the asymptomatic population. (Auth.)

  6. Stress-induced ST-segment deviation in relation to the presence and severity of coronary artery disease in patients with normal myocardial perfusion imaging.

    Science.gov (United States)

    Weinsaft, Jonathan W; Manoushagian, Shant J; Patel, Taral; Shakoor, Aqsa; Kim, Robert J; Mirchandani, Sunil; Lin, Fay; Wong, Franklin J; Szulc, Massimiliano; Okin, Peter M; Kligfield, Paul D; Min, James K

    2009-01-01

    To assess the utility of stress electrocardiography (ECG) for identifying the presence and severity of obstructive coronary artery disease (CAD) defined by coronary computed tomographic angiography (CCTA) among patients with normal nuclear myocardial perfusion imaging (MPI). The study population comprised 119 consecutive patients with normal MPI who also underwent CCTA (interval 3.5+/-3.8 months). Stress ECG was performed at the time of MPI. CCTA and MPI were interpreted using established scoring systems, and CCTA was used to define the presence and extent of CAD, which was quantified by a coronary artery jeopardy score. Within this population, 28 patients (24%) had obstructive CAD identified by CCTA. The most common CAD pattern was single-vessel CAD (61%), although proximal vessel involvement was present in 46% of patients. Patients with CAD were nearly three times more likely to have positive standard test responses (1 mm ST-segment deviation) than patients with patent coronary arteries (36 vs. 13%, P=0.007). In multivariate analysis, a positive ST-segment test response was an independent marker for CAD (odds ratio: 2.02, confidence interval: 1.09-3.78, P=0.03) even after adjustment for a composite of clinical cardiac risk factors (odds ratio: 1.85, confidence interval: 1.05-3.23, P=0.03). Despite uniformly normal MPI, mean coronary jeopardy score was three-fold higher among patients with positive compared to those with negative ST-segment response to exercise or dobutamine stress (1.9+/-2.7 vs. 0.5+/-1.4, P=0.03). Stress-induced ST-segment deviation is an independent marker for obstructive CAD among patients with normal MPI. A positive stress ECG identifies patients with a greater anatomic extent of CAD as quantified by coronary jeopardy score.

  7. [Image fusion of gated-SPECT and CT angiography in coronary artery disease. Importance of anatomic-functional correlation].

    Science.gov (United States)

    Nazarena Pizzi, M; Aguadé Bruix, S; Cuéllar Calabria, H; Aliaga, V; Candell Riera, J

    2010-01-01

    A 77-year old patient was admitted for acute coronary syndrome without ST elevation. His risk was stratified using the myocardial perfusion gated SPECT, mild inferior ischemia being observed. Thus, medical therapy was optimized and the patient was discharged. He continued with exertional dyspnea so a coronary CT angiography was performed. It revealed severe lesions in the proximal RCA. SPECT-CT fusion images correlated the myocardial perfusion defect with a posterior descending artery from the RCA, in a co-dominant coronary area. Subsequently, cardiac catheterism was indicated for his treatment. The current use of image fusion studies is limited to patients in whom it is difficult to attribute a perfusion defect to a specific coronary artery. In our patient, the fusion images helped to distinguish between the RCA and the circumflex artery as the culprit artery of ischemia. Copyright © 2010 Elsevier España, S.L. y SEMNIM. All rights reserved.

  8. Usefulness of combination post-stress dysfunction and perfusion imaging in technetium-99m-tetrofosmin myocardial scintigraphy

    International Nuclear Information System (INIS)

    Yamazaki, Yoko; Imai, Kamon; Konaka, Ryohei; Nakajima, Takatomo; Goto, Sayaka; Horie, Toshinobu; Saito, Satoshi; Ozawa, Yukio; Kanmatsuse, Katsuo

    2001-01-01

    Myocardial perfusion imaging has lower sensitivity for the diagnosis of coronary artery disease in patients with three-vessel disease. The presence of post-stress dysfunction of the left ventricle, evaluated by electrocardiography (ECG) gated single photon emission computed tomography (SPECT) with a quantitative gated SPECT program, was investigated in patients with coronary artery disease, and also whether combining post-stress dysfunction and myocardial perfusion imaging improved the diagnosis of coronary artery disease. ECG gated technetium-99m-tetrofosmin SPECT was performed using a one day, stress and rest, protocol in 139 patients. SPECT and coronary angiography were performed within 1 month. The coronary artery disease group consisted of 89 patients: 43 with one-vessel disease (1VD), 28 with two-vessel disease (2VD), and 18 with three-vessel disease (3VD). The group with zero-vessel disease (0VD) consisted of 50 patients. According to post-stress and rest ejection fraction (EF) and end-systolic volume (ESV), post-stress dysfunction is defined as follows: rest EF - post-stress EF≥5% and post-stress ESV - rest ESV≥5ml. In the coronary artery disease group, post-stress ESV was larger than rest ESV (37.8±26.4, 34.0±24.2 ml, p<0.001), and post-stress EF was lower than rest EF (61.5±11.1%, 64.2±10.8%, p<0.001). In the 0VD group, ESV and EF were the same for post-stress and rest (25.7±20.8, 26.2±21.6 ml, NS; 70.4±9.5%, 70.0±9.6%, NS). Post-stress dysfunction was 6.0% in the 0VD group and 30.3% in the coronary artery disease group (p<0.001). Furthermore, post-stress dysfunction in the 2VD (35.7%) and 3VD (38.9%) groups was higher than that in the 0VD group (p<0.01, p<0.01). Sensitivity of coronary artery disease diagnosis by myocardial perfusion imaging was 75%. The combination of post-stress dysfunction and myocardial perfusion imaging improved sensitivity from 75% to 82% (p<0.05), but reduced the specificity from 92% to 86% (p=0.08). Post

  9. Safety of adenosine stress myocardial perfusion imaging by a one-route infusion protocol

    International Nuclear Information System (INIS)

    Kawai, Yuko; Kishino, Koh

    2006-01-01

    When adenosine stress testing is performed, a vein is generally accessed in each arm. To determine whether the one-route infusion protocol, that is, infusion via one upper arm vein, is safe, myocardial perfusion imaging was performed during adenosine stress testing in patients with angina pectoris. Sixty-six consecutive patients (43 men, 68±11 years of age) with suspected coronary artery disease were enrolled in this study. For the stress test, adenosine was injected at 120 μg/kg/min for 6 minutes. Systolic blood pressure, diastolic blood pressure, and heart rate did not show any significant changes after injection of the adenosine and radioisotope (RI) tracer. Adverse events during infusion of the adenosine were seen in 42 (64%) patients and included chest discomfort/oppression in 17 (26%) and dyspnea/throat discomfort in 15 (23%). On the other hand, adverse events just after infusion of the RI tracer occurred in 5 (8%) patients and included chest oppression in 2 (3%) and dyspnea in 1 (2%). Almost all adverse events disappeared quickly without treatment. Therefore, we concluded that adenosine stress myocardial perfusion imaging using a one-route infusion protocol is safe and useful to do for patients unable to secure veins in both arms. (author)

  10. Effect of tamoxifen on the coronary vascular reactivity of spontaneously hypertensive female rats

    Directory of Open Access Journals (Sweden)

    M.V. Borgo

    2011-08-01

    Full Text Available Tamoxifen has been associated with a reduction in the incidence of myocardial infarction. However, the effects of tamoxifen on coronary reactivity have not been fully elucidated. The objective of this study was to determine the effects of chronic treatment with tamoxifen on coronary vascular reactivity in spontaneously hypertensive rats (SHR. Female SHR were divided into four groups (N = 7 each: sham-operated (SHAM, sham-operated and treated with tamoxifen (10 mg/kg by gavage for 90 days (TAMOX, ovariectomized (OVX, and ovariectomized and treated with tamoxifen (OVX+TAMOX. Mean arterial pressure (MAP, heart rate (HR, coronary perfusion pressure (CPP, and coronary vascular reactivity were measured. MAP and HR were reduced (9.42 and 11.67%, respectively in the OVX+TAMOX group compared to the OVX group (P < 0.01. The coronary vascular reactivity of the OVX+TAMOX group presented smaller vasoconstrictor responses to acetylcholine (2-64 µg when compared to the OVX group (P < 0.01 and this response was similar to that of the SHAM group. The adenosine-induced vasodilator response was greater in the TAMOX group compared to the SHAM and OVX groups (P < 0.05. Baseline CPP was higher in OVX+TAMOX and TAMOX groups (136 ± 3.6 and 130 ± 1.5 mmHg than in OVX and SHAM groups (96 ± 2 and 119 ± 2.3 mmHg; P < 0.01. Tamoxifen, when combined with OVX, attenuated the vasoconstriction induced by acetylcholine and increased the adenosine-induced vasodilatory response, as well as reducing the MAP, suggesting beneficial effects of tamoxifen therapy on coronary vascular reactivity after menopause.

  11. Myocardial perfusion modeling using MRI

    DEFF Research Database (Denmark)

    Larsson, H B; Fritz-Hansen, T; Rostrup, Egill

    1996-01-01

    In the present study, it is shown that it is possible to quantify myocardial perfusion using magnetic resonance imaging in combination with gadolinium diethylenetriaminopentaacetic acid (Gd-DTPA). Previously, a simple model and method for measuring myocardial perfusion using an inversion recovery...... turbo-FLASH (fast low-angle shot) sequence and Gd-DTPA has been presented. Here, an extension of the model is presented taking into account fast and slow water exchange between the compartments, enabling the calculation of the unidirectional influx constant (Ki) for Gd-DTPA, the distribution volume...... of Gd-DTPA (lambda), the vascular blood volume (Vb), and the time delay through the coronary arteries (delta T). The model was evaluated by computer simulation and used on experimental results from seven healthy subjects. The results in the healthy volunteers for a region of interest placed...

  12. Quantitation of the critically ischemic zone at risk during acute coronary occlusion using PET

    International Nuclear Information System (INIS)

    Merhige, M.; Garza, D.; Sease, D.; Rowe, R.W.; Tewson, T.; Emran, A.; Bolomey, L.; Gould, K.L.

    1991-01-01

    Critical myocardial ischemia has been defined experimentally during acute coronary occlusion as flow reduction of 50% or more since cellular ATP depletion begins to occur beyond this flow reduction threshold, placing tissue at risk of cellular injury. To test the hypothesis that critically ischemic fractional left ventricular mass can be measured noninvasively with PET, nine dogs were imaged in a multi-slice positron camera using the perfusion tracer 13N-ammonia, while radiolabeled microspheres were injected into the left atrium during acute coronary occlusion. Images were processed using a 50% threshold and the size of the resulting perfusion defect was expressed as a fraction of total left ventricular image volume. The critically ischemic left ventricular fraction determined in vitro from the microsphere perfusion data, ranged from 5% to 30% of the total left ventricular weight and correlated closely with that determined noninvasively by PET with r = 0.94 (y = 1.05X - 2.0%). The authors conclude that the fraction of left ventricular myocardium rendered critically ischemic during acute coronary occlusion can be measured accurately and noninvasively in vivo using perfusion imaging with positron emission tomography

  13. Patient-centric blood pressure-targeted cardiopulmonary resuscitation improves survival from cardiac arrest.

    Science.gov (United States)

    Sutton, Robert M; Friess, Stuart H; Naim, Maryam Y; Lampe, Joshua W; Bratinov, George; Weiland, Theodore R; Garuccio, Mia; Nadkarni, Vinay M; Becker, Lance B; Berg, Robert A

    2014-12-01

    Although current resuscitation guidelines are rescuer focused, the opportunity exists to develop patient-centered resuscitation strategies that optimize the hemodynamic response of the individual in the hopes to improve survival. To determine if titrating cardiopulmonary resuscitation (CPR) to blood pressure would improve 24-hour survival compared with traditional CPR in a porcine model of asphyxia-associated ventricular fibrillation (VF). After 7 minutes of asphyxia, followed by VF, 20 female 3-month-old swine randomly received either blood pressure-targeted care consisting of titration of compression depth to a systolic blood pressure of 100 mm Hg and vasopressors to a coronary perfusion pressure greater than 20 mm Hg (BP care); or optimal American Heart Association Guideline care consisting of depth of 51 mm with standard advanced cardiac life support epinephrine dosing (Guideline care). All animals received manual CPR for 10 minutes before first shock. Primary outcome was 24-hour survival. The 24-hour survival was higher in the BP care group (8 of 10) compared with Guideline care (0 of 10); P = 0.001. Coronary perfusion pressure was higher in the BP care group (point estimate +8.5 mm Hg; 95% confidence interval, 3.9-13.0 mm Hg; P < 0.01); however, depth was higher in Guideline care (point estimate +9.3 mm; 95% confidence interval, 6.0-12.5 mm; P < 0.01). Number of vasopressor doses before first shock was higher in the BP care group versus Guideline care (median, 3 [range, 0-3] vs. 2 [range, 2-2]; P = 0.003). Blood pressure-targeted CPR improves 24-hour survival compared with optimal American Heart Association care in a porcine model of asphyxia-associated VF cardiac arrest.

  14. Chronotropic response to vasodilator-stress in patients submitted to myocardial perfusion imaging: impact on the accuracy in detecting coronary stenosis

    International Nuclear Information System (INIS)

    Gimelli, Alessia; Coceani, Michele; Quaranta, Angela; Emdin, Michele; Liga, Riccardo; Marzullo, Paolo

    2015-01-01

    A lower heart rate response (HRR) during vasodilator MPI has been shown to have a relevant adverse prognostic impact. We sought to evaluate the interaction among individual HRR to vasodilator stress and myocardial perfusion imaging (MPI) accuracy in patients with suspected ischemic heart disease (IHD). One hundred and sixty-five consecutive patients were submitted to vasodilator-stress MPI on a cardiac camera equipped with cadmium-zinc-thelluride detectors and coronary angiography. A coronary stenosis >70 % was considered significant. In every patient, the summed difference score (SDS) was computed from MPI images. Patients were categorized according to the tertiles of the distribution of individual HRR during dipyridamole: ''Group 1'' (HRR < 8 bpm; lowest tertile); ''Group 2'' (8 ≤ HRR ≤ 12 bpm; middle tertile); ''Group 3'' (HRR >12 bpm; highest tertile). Significant coronary artery disease (CAD) was present in 102 (62 %) patients. In the overall population, MPI showed a significant accuracy (AUC: 0.81, 95 % CI 0.74-0.86; p < 0.001) in unmasking the presence of significant coronary stenosis. Interestingly, in patients with a blunted HRR during dipyridamole (''Group 1'') MPI showed a significantly lower sensitivity (68 %) in detecting CAD than in those with a higher HRR (''Group 3'') (91 %, p = 0.007), despite a preserved specificity (76 % vs 77 %, P=NS). Similarly, the correlation among CAD extent and post-stress LV functional stunning was limited to ''Group 3'' patients, while it disappeared in those with blunted HRR. In patients with suspected IHD, MPI sensitivity is strongly influenced by the magnitude of patient heart rate increase to the pharmacologic stressor, suggesting an interaction among blunted HRR and lower accuracy in unmasking CAD. (orig.)

  15. Chronotropic response to vasodilator-stress in patients submitted to myocardial perfusion imaging: impact on the accuracy in detecting coronary stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Gimelli, Alessia; Coceani, Michele; Quaranta, Angela; Emdin, Michele [Fondazione Toscana Gabriele Monasterio, Pisa (Italy); Liga, Riccardo [University Hospital of Pisa, Cardio-Thoracic and Vascular Department, Pisa (Italy); Marzullo, Paolo [Fondazione Toscana Gabriele Monasterio, Pisa (Italy); CNR, Institute of Clinical Physiology, Pisa (Italy)

    2015-11-15

    A lower heart rate response (HRR) during vasodilator MPI has been shown to have a relevant adverse prognostic impact. We sought to evaluate the interaction among individual HRR to vasodilator stress and myocardial perfusion imaging (MPI) accuracy in patients with suspected ischemic heart disease (IHD). One hundred and sixty-five consecutive patients were submitted to vasodilator-stress MPI on a cardiac camera equipped with cadmium-zinc-thelluride detectors and coronary angiography. A coronary stenosis >70 % was considered significant. In every patient, the summed difference score (SDS) was computed from MPI images. Patients were categorized according to the tertiles of the distribution of individual HRR during dipyridamole: ''Group 1'' (HRR < 8 bpm; lowest tertile); ''Group 2'' (8 ≤ HRR ≤ 12 bpm; middle tertile); ''Group 3'' (HRR >12 bpm; highest tertile). Significant coronary artery disease (CAD) was present in 102 (62 %) patients. In the overall population, MPI showed a significant accuracy (AUC: 0.81, 95 % CI 0.74-0.86; p < 0.001) in unmasking the presence of significant coronary stenosis. Interestingly, in patients with a blunted HRR during dipyridamole (''Group 1'') MPI showed a significantly lower sensitivity (68 %) in detecting CAD than in those with a higher HRR (''Group 3'') (91 %, p = 0.007), despite a preserved specificity (76 % vs 77 %, P=NS). Similarly, the correlation among CAD extent and post-stress LV functional stunning was limited to ''Group 3'' patients, while it disappeared in those with blunted HRR. In patients with suspected IHD, MPI sensitivity is strongly influenced by the magnitude of patient heart rate increase to the pharmacologic stressor, suggesting an interaction among blunted HRR and lower accuracy in unmasking CAD. (orig.)

  16. Coronary blood flow during cardiopulmonary resuscitation in swine

    International Nuclear Information System (INIS)

    Bellamy, R.F.; DeGuzman, L.R.; Pedersen, D.C.

    1984-01-01

    Recent papers have raised doubt as to the magnitude of coronary blood flow during closed-chest cardiopulmonary resuscitation. We will describe experiments that concern the methods of coronary flow measurement during cardiopulmonary resuscitation. Nine anesthetized swine were instrumented to allow simultaneous measurements of coronary blood flow by both electromagnetic cuff flow probes and by the radiomicrosphere technique. Cardiac arrest was caused by electrical fibrillation and closed-chest massage was performed by a Thumper (Dixie Medical Inc., Houston). The chest was compressed transversely at a rate of 66 strokes/min. Compression occupied one-half of the massage cycle. Three different Thumper piston strokes were studied: 1.5, 2, and 2.5 inches. Mean aortic pressure and total systemic blood flow measured by the radiomicrosphere technique increased as Thumper piston stroke was lengthened (mean +/- SD): 1.5 inch stroke, 23 +/- 4 mm Hg, 525 +/- 195 ml/min; 2 inch stroke, 33 +/- 5 mm Hg, 692 +/- 202 ml/min; 2.5 inch stroke, 40 +/- 6 mm Hg, 817 +/- 321 ml/min. Both methods of coronary flow measurement (electromagnetic [EMF] and radiomicrosphere [RMS]) gave similar results in technically successful preparations (data expressed as percent prearrest flow mean +/- 1 SD): 1.5 inch stroke, EMF 12 +/- 5%, RMS 16 +/- 5%; 2 inch stroke, EMF 30 +/- 6%, RMS 26 +/- 11%; 2.5 inch stroke, EMF 50 +/- 12%, RMS 40 +/- 20%. The phasic coronary flow signal during closed-chest compression indicated that all perfusion occurred during the relaxation phase of the massage cycle. We concluded that coronary blood flow is demonstrable during closed-chest massage, but that the magnitude is unlikely to be more than a fraction of normal

  17. Post Traumatic Cerebral Oedema in Severe Head Injury is Related to Intracranial Pressure and Cerebral Perfusion Pressure but not to Cerebral Compliance

    Directory of Open Access Journals (Sweden)

    U Nujaimin

    2009-07-01

    Full Text Available This was a prospective cohort study, carried out in the Neuro Intensive Care Unit, Department of Neurosciences, Hospital Universiti Sains Malaysia, Kubang Kerian Kelantan. The study was approved by the local ethics committee and was conducted between November 2005 and September 2007 with a total of 30 patients included in the study. In our study, univariate analysis showed a statistically significant relationship between mean intracranial pressure (ICP as well as cerebral perfusion pressure (CPP with both states of basal cistern and the degree of diffuse injury and oedema based on the Marshall classification system. The ICP was higher while CPP and compliance were lower whenever the basal cisterns were effaced in cases of cerebral oedema with Marshall III and IV. In comparison, the study revealed lower ICP, higher mean CPP and better mean cerebral compliance if the basal cisterns were opened or the post operative CT brain scan showed Marshall I and II. These findings suggested the surgical evacuation of clots to reduce the mass volume and restoration of brain anatomy may reduce vascular engorgement and cerebral oedema, therefore preventing intracranial hypertension, and improving cerebral perfusion pressure and cerebral compliance. Nevertheless the study did not find any significant relationship between midline shifts and mean ICP, CPP or cerebral compliance even though lower ICP, higher CPP and compliance were frequently observed when the midline shift was less than 0.5 cm. As the majority of our patients had multiple and diffuse brain injuries, the absence of midline shift did not necessarily mean lower ICP as the pathology was bilateral and even when after excluding the multiple lesions, the result remained insignificant. We assumed that the CT brain scan obtained after evacuation of the mass lesion to assess the state basal cistern and classify the diffuse oedema may prognosticate the intracranial pressure and cerebral perfusion pressure

  18. Comparative Study between Perfusion Changes and Positive Findings on Coronary Flow Reserve

    Directory of Open Access Journals (Sweden)

    Costantino Roberto Frack Costantini

    Full Text Available Abstract Background: Functional assessment of coronary artery obstruction is used in cardiology practice to correlate anatomic obstructions with flow decrease. Among such assessments, the study of the coronary fractional flow reserve (FFR has become the most widely used. Objective: To evaluate the correlation between FFR and findings of ischemia obtained by noninvasive methods including stress echocardiography and nuclear medicine and the presence of critical coronary artery obstruction. Methods: Retrospective study of cases treated with systematized and standardized procedures for coronary disease between March 2011 and August 2014. We included 96 patients with 107 critical coronary obstructions (> 50% in the coronary trunk and/or ≥ 70% in other segments estimated by quantitative coronary angiography (QCA and intracoronary ultrasound (ICUS. All cases presented ischemia in one of the noninvasive studies. Results: All 96 patients presented ischemia (100% in one of the functional tests. On FFR study with adenosine 140 g/kg/min, 52% of the cases had values ≤ 0.80. On correlation analysis for FFR ≤ 0.80, the evaluation of sensitivity, specificity, positive and negative predictive values, accuracy, and ROC curve in relation to the stenosis degree and length, and presence of ischemia, no significant values or strong correlation were observed. Conclusion: Coronary FFR using a cut-off value of 0.80 showed no correlation with noninvasive ischemia tests in patients with severe coronary artery obstructions on QCA and ICUS.

  19. Ivabradine in acute coronary syndromes: Protection beyond heart rate lowering.

    Science.gov (United States)

    Niccoli, Giampaolo; Borovac, Josip Anđelo; Vetrugno, Vincenzo; Camici, Paolo G; Crea, Filippo

    2017-06-01

    Ivabradine is a heart rate reducing agent that exhibits anti-ischemic effects through the inhibition of funny electrical current in the sinus node resulting in heart rate reduction, thus enabling longer diastolic perfusion time, and reduced myocardial oxygen consumption without detrimental changes in arterial blood pressure, coronary vasomotion, and ventricular contractility. The current guideline-based clinical use of Ivabradine is reserved for patients with stable angina pectoris who cannot tolerate or whose symptoms are inadequately controlled with beta blockers. In patients with chronic heart failure and reduced ejection fraction, Ivabradine has demonstrated beneficial effects in improving clinical outcomes when added to conventional therapy. However, the role of Ivabradine in acute coronary syndromes has not been established. Based on the results from some relevant preclinical studies and a limited amount of clinical data that were reported recently, the role of Ivabradine in acute ischemic events warrants further investigation. The aim of this review is to provide an overview of the available literature on the potential role of Ivabradine in the clinical context of acute coronary syndromes. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. AdVEGF-B186 and AdVEGF-DΔNΔC induce angiogenesis and increase perfusion in porcine myocardium.

    Science.gov (United States)

    Nurro, Jussi; Halonen, Paavo J; Kuivanen, Antti; Tarkia, Miikka; Saraste, Antti; Honkonen, Krista; Lähteenvuo, Johanna; Rissanen, Tuomas T; Knuuti, Juhani; Ylä-Herttuala, Seppo

    2016-11-01

    Coronary heart disease remains a significant clinical problem, and new therapies are needed especially for patients with refractory angina for whom the current therapies do not provide sufficient relief. The aim of this study was to find out if angiogenic gene therapy using new members of the vascular endothelial growth factor (VEGF) family, VEGF-B 186 and VEGF-D ΔNΔC , increase myocardial perfusion as measured by the positron emission tomography (PET) 15 O-imaging, and whether there would be coronary steal effect to the contralateral side. Furthermore, safety of intramyocardial angiogenic adenoviral gene transfer was evaluated. Intramyocardial adenoviral (Ad) VEGF-B 186 or AdVEGF-D ΔNΔC gene transfers were given endovascularly into the porcine posterolateral wall of the left ventricle (n=34). Six days later, PET 15 O-imaging for myocardial perfusion and coronary angiography were performed. AdVEGF-B 186 and AdVEGF-D ΔNΔC induced angiogenesis and increased total microvascular area 1.8-fold (95% CI 0.2 to 3.5) and 2.8-fold (95% CI 1.4 to 4.3), respectively. At rest, perfusion was maintained at normal levels, but at stress, relative perfusion was increased 1.4-fold (95% CI 1.1 to 1.7) for AdVEGF-B 186 and 1.3-fold (95% CI 1.0 to 1.7) for AdVEGF-D ΔNΔC , without causing coronary steal effect in the control area. The therapy was well tolerated and did not lead to any significant changes in laboratory safety parameters. Both AdVEGF-B 186 and AdVEGF-D ΔNΔC gene transfers induced efficient angiogenesis in the myocardium resulting in an increased myocardial perfusion measured by PET. Importantly, local perfusion increase did not induce any coronary steal effect. As such, both treatments seem suitable new candidates for the induction of therapeutic angiogenesis for the treatment of refractory angina. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  1. Brain Natriuretic Peptide, Atrial Natriuretic Peptide and Endothelin-1 response to peak exercise in patients with coronary artery disease and correlation with myocardial perfusion scintigraphy abnormalities

    International Nuclear Information System (INIS)

    Erbas, B.; Ergun, E.; Koray, Z.; Kabakci, G.; Yildirir, A.; Kes, S.

    2002-01-01

    Aim: Plasma Brain Natriuretic Peptide (BNP) has been known as a promising marker of ventricular dysfunction in cardiac patients. There are conflicting reports about its response to exercise testing. Therefore, this study was performed to investigate the exercise induced changes in BNP, Atrial Natriuretic Peptide (ANP) and Endothelin-1 (E) levels and their correlation with perfusion abnormalities on myocardial perfusion scintigraphy (MPS). Materials and Methods: Study group consisted of 35 patients (mean age=53.9+11.8) who underwent MPS with suspicion or diagnosis of coronary artery disease. Plasma levels of BNP, ANP, and E were measured at rest and after symptom-limited ergometry. Patients were divided into two groups according to the presence of perfusion abnormality (i.e. ischemia or infarction) on MPS. Results: BNP, ANP and E levels did not change significantly with exercise, however baseline levels of BNP, ANP levels and peak-exercise level of BNP in patients with perfusion abnormalities were significantly higher. Hypertensive patients with or without perfusion abnormalities had higher baseline BNP, ANP levels, and peak-exercise BNP levels compared to normotensives. BNP levels at rest and after exercise had a significant correlation with age (r=0.57, p=0.04; r=0.58, p=0.04), as well as baseline ANP values (r=0.37, p=0.033). Highest baseline BNP, ANP and exercise BNP levels were observed in patients with infarction. Conclusion: Exercise-testing did not induce significant changes in plasma levels of BNP, ANP and E. Higher BNP levels had correlation with the presence of ischemia, infarction and hypertension, as well as, increasing age

  2. PX-18 Protects Human Saphenous Vein Endothelial Cells under Arterial Blood Pressure.

    Science.gov (United States)

    Kupreishvili, Koba; Stooker, Wim; Emmens, Reindert W; Vonk, Alexander B A; Sipkens, Jessica A; van Dijk, Annemieke; Eijsman, Leon; Quax, Paul H; van Hinsbergh, Victor W M; Krijnen, Paul A J; Niessen, Hans W M

    2017-07-01

    Arterial blood pressure-induced shear stress causes endothelial cell apoptosis and inflammation in vein grafts after coronary artery bypass grafting. As the inflammatory protein type IIA secretory phospholipase A 2 (sPLA 2 -IIA) has been shown to progress atherosclerosis, we hypothesized a role for sPLA 2 -IIA herein. The effects of PX-18, an inhibitor of both sPLA 2 -IIA and apoptosis, on residual endothelium and the presence of sPLA 2 -IIA were studied in human saphenous vein segments (n = 6) perfused at arterial blood pressure with autologous blood for 6 hrs. The presence of PX-18 in the perfusion blood induced a significant 20% reduction in endothelial cell loss compared to veins perfused without PX18, coinciding with significantly reduced sPLA 2 -IIA levels in the media of the vein graft wall. In addition, PX-18 significantly attenuated caspase-3 activation in human umbilical vein endothelial cells subjected to shear stress via mechanical stretch independent of sPLA 2 -IIA. In conclusion, PX-18 protects saphenous vein endothelial cells from arterial blood pressure-induced death, possibly also independent of sPLA 2 -IIA inhibition. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Paradoxical hypotension during dobutamine infusion for myocardial perfusion scintigraphy

    International Nuclear Information System (INIS)

    Erguen, E.L.; Caner, B.; Atalar, E.; Karanfil, A.; Tokgoezoglu, L.

    1998-01-01

    Dobutamine as a predominant beta-1 agonist increases heart rate and myocardial contractility and at sufficient high doses, it also increases systolic blood pressure. This study was undertaken to describe instances of paradoxical hypotension during dobutamine infusion for Tl-201 myocardial perfusion SPECT study and the relationship between scintigraphic findings and hypotension occurred during dobutamine infusion. Methods: In 201 consecutive patients unable to perform adequate exercise, dobutamine Tl-201 myocardial SPECT was performed. Dobutamine was infused starting from 10 μg/kg/min increasing to 40 μ/kg/min. Paradoxical hypotension was defined as a decrease in systolic blood pressure ≥ 20 mmHg compared with baseline study. Paradoxical hypotension was observed in 40 patients (Group A) out of 201 (19.9%) while no significant change in systolic blood pressure was detected in the remaining 161 patients (Group B). Mean maximum fall in systolic blood pressure was 39±18 mmHg (range: 20-90). In 33 of 40 patients (83%) with paradoxical hypotension, scintigraphy was normal compared to 131 (81%) of the remaining 161 patients. In patients of Group A, angiography, echocardiography and tilt table tests were performed in 13, 11 and 6 patients respectively. Nine of 13 angiographic evaluations (69%), 10 of 11 echocardiographic evaluations (91%), all of the tilt table tests were normal. Additionally, all of the patients of Group A were clinically followed up at least 6 months after the myocardial perfusion scintigraphy. None of the patients had a cardiac event except one patient during the follow-up period. Conclusion: Paradoxical hypotension during dobutamine infusion for myocardial scintigraphy is not an uncommon finding and up to 19.9% patients may develop such hypotension. To maximize test safety, precautions should be taken during dobutamine myocardial stress test, since remarkable decrease in systolic blood pressure may occur. Unlike hypotension occurring with exercise

  4. Magnetic resonance cardiac perfusion imaging-a clinical perspective

    International Nuclear Information System (INIS)

    Hunold, Peter; Schlosser, Thomas; Barkhausen, Joerg

    2006-01-01

    Coronary artery disease (CAD) with its clinical appearance of stable or unstable angina and acute myocardial infarction is the leading cause of death in developed countries. In view of increasing costs and the rising number of CAD patients, there has been a major interest in reliable non-invasive imaging techniques to identify CAD in an early (i.e. asymptomatic) stage. Since myocardial perfusion deficits appear very early in the ''ischemic cascade'', a major breakthrough would be the non-invasive quantification of myocardial perfusion before functional impairment might be detected. Therefore, there is growing interest in other, target-organ-specific parameters, such as relative and absolute myocardial perfusion imaging. Magnetic resonance (MR) imaging has been proven to offer attractive concepts in this respect. However, some important difficulties have not been resolved so far, which still causes uncertainty and prevents the broad application of MR perfusion imaging in a clinical setting. This review explores recent technical developments in MR hardware, software and contrast agents, as well as their impact on the current and future clinical status of MR imaging of first-pass myocardial perfusion imaging. (orig.)

  5. Magnetic resonance cardiac perfusion imaging-a clinical perspective

    Energy Technology Data Exchange (ETDEWEB)

    Hunold, Peter; Schlosser, Thomas; Barkhausen, Joerg [University Hospital, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany)

    2006-08-15

    Coronary artery disease (CAD) with its clinical appearance of stable or unstable angina and acute myocardial infarction is the leading cause of death in developed countries. In view of increasing costs and the rising number of CAD patients, there has been a major interest in reliable non-invasive imaging techniques to identify CAD in an early (i.e. asymptomatic) stage. Since myocardial perfusion deficits appear very early in the ''ischemic cascade'', a major breakthrough would be the non-invasive quantification of myocardial perfusion before functional impairment might be detected. Therefore, there is growing interest in other, target-organ-specific parameters, such as relative and absolute myocardial perfusion imaging. Magnetic resonance (MR) imaging has been proven to offer attractive concepts in this respect. However, some important difficulties have not been resolved so far, which still causes uncertainty and prevents the broad application of MR perfusion imaging in a clinical setting. This review explores recent technical developments in MR hardware, software and contrast agents, as well as their impact on the current and future clinical status of MR imaging of first-pass myocardial perfusion imaging. (orig.)

  6. Functional Information in Coronary Artery Disease

    DEFF Research Database (Denmark)

    Kofoed, Klaus F; Sørgaard, Mathias H; Linde, Jesper J

    2017-01-01

    as an add-on to standard coronary CT angiography (CCTA), to identify regions of myocardial hypoperfusion, at rest and during adenosine stress. The principle of measurement is well-validated in animal experimental models, and CT myocardial perfusion imaging has a high degree of concordance with already...

  7. Normal stress-only myocardial single photon emission computed tomography predicts good outcome in patients with coronary artery stenoses between 40 and 70.

    Science.gov (United States)

    Jiang, Zhixin; Liu, Yangqing; Xin, Chaofan; Zhou, Yanli; Wang, Cheng; Zhao, Zhongqiang; Li, Chunxiang; Li, Dianfu

    2016-09-01

    Normal stress myocardial single photon emission computed tomography (SPECT) usually indicates good physiologic function of all coronary lesions, and also indicates a good outcome. We hypothesize that it can still predict good outcome in patients with coronary stenoses between 40 and 70%. A group of patients who underwent stress myocardial SPECT after coronary angiography were consecutively recruited in our center. Patients were eligible if they had one or more coronary stenoses between 40 and 70%. Patients with coronary stenoses greater than 50% diameter of left main or greater than 70% diameter of nonleft main epicardial vessels, and left ventricular ejection fraction less than 50% were excluded. The outcome was defined as major adverse events, including cardiac death, nonfatal myocardial infarction, and revascularization. Patients' survival curves were constructed accorded to the method of Kaplan and Meier and compared using the log-rank test. A study cohort of 77 patients was enrolled. According to the summed stress score, 43 patients were assigned to the perfusion defect group and 34 patients were assigned to the perfusion normal group. The follow-up duration was 6.4±0.3 years. In the perfusion normal group, only one of 34 (2.9%) patients developed major adverse events. In the perfusion defect group, six of 43 (14%) developed major adverse events, P-value of 0.041. It is safe to defer a percutaneous coronary intervention in patients with coronary stenoses between 40 and 70% and normal stress myocardial SPECT.

  8. Adenosine-induced coronary flow reserve in Watanabe heritable hyperlipidemic rabbits

    Energy Technology Data Exchange (ETDEWEB)

    Shimada, Kazuhiro; Yoshida, Katsuya [Chiba Univ. (Japan). School of Medicine; Tadokoro, Hiroyuki [and others

    2000-12-01

    The Watanabe heritable hyperlipidemic (WHHL) rabbit develops coronary atherosclerosis and hypercholesterolemia because of a genetic deficiency of low-density lipoprotein receptors and is therefore a good animal model for studying the relationships of coronary atherosclerosis, hypercholesterolemia and coronary flow reserve. The aim of the present study was to assess myocardial perfusion at baseline and during adenosine infusion (0.2 mg{center_dot}kg{sup -1}{center_dot}min{sup -1}) in 8 WHHL rabbits (13.8{+-}0.5 months) with {sup 13}N-ammonia, small-animal positron emission tomography (PET) and colored microspheres. Results were compared with those from 6 age-matched Japanese white rabbits. Plaque distribution was also examined in the extramural coronary arteries. All 8 WHHL rabbits had coronary plaques, with 6 showing multiple plaques. Mean global myocardial blood flow (ml{center_dot}min{sup -1}{center_dot}g{sup -1}) did not differ significantly between control and WHHL groups both at baseline (3.67{+-}0.72 vs 4.26{+-}1.12 ml{center_dot}min{sup -1}{center_dot}g{sup -1}, p=NS) and with adenosine (7.92{+-}2.00 vs 9.27{+-}2.91 ml{center_dot}min{sup -1}{center_dot}g{sup -1}, p=NS), nor did coronary flow reserve (2.16{+-}0.37 vs 2.18{+-}0.41, p=NS). None showed evidence of regional perfusion abnormalities by visual and semiquantitative analyses of PET images. It was concluded that WHHL rabbits preserve adenosine-induced coronary flow reserve despite coronary atherosclerosis and hypercholesterolemia, suggesting that a compensatory mechanism develops in this animal model. (author)

  9. Adenosine-induced coronary flow reserve in Watanabe heritable hyperlipidemic rabbits

    International Nuclear Information System (INIS)

    Shimada, Kazuhiro; Yoshida, Katsuya; Tadokoro, Hiroyuki

    2000-01-01

    The Watanabe heritable hyperlipidemic (WHHL) rabbit develops coronary atherosclerosis and hypercholesterolemia because of a genetic deficiency of low-density lipoprotein receptors and is therefore a good animal model for studying the relationships of coronary atherosclerosis, hypercholesterolemia and coronary flow reserve. The aim of the present study was to assess myocardial perfusion at baseline and during adenosine infusion (0.2 mg·kg -1 ·min -1 ) in 8 WHHL rabbits (13.8±0.5 months) with 13 N-ammonia, small-animal positron emission tomography (PET) and colored microspheres. Results were compared with those from 6 age-matched Japanese white rabbits. Plaque distribution was also examined in the extramural coronary arteries. All 8 WHHL rabbits had coronary plaques, with 6 showing multiple plaques. Mean global myocardial blood flow (ml·min -1 ·g -1 ) did not differ significantly between control and WHHL groups both at baseline (3.67±0.72 vs 4.26±1.12 ml·min -1 ·g -1 , p=NS) and with adenosine (7.92±2.00 vs 9.27±2.91 ml·min -1 ·g -1 , p=NS), nor did coronary flow reserve (2.16±0.37 vs 2.18±0.41, p=NS). None showed evidence of regional perfusion abnormalities by visual and semiquantitative analyses of PET images. It was concluded that WHHL rabbits preserve adenosine-induced coronary flow reserve despite coronary atherosclerosis and hypercholesterolemia, suggesting that a compensatory mechanism develops in this animal model. (author)

  10. Effects of coil closure of patent ductus arteriosus on left anterior descending coronary artery blood flow using transthoracic Doppler echocardiography.

    Science.gov (United States)

    Harada, Kenji; Toyono, Manotomo; Tamura, Masamichi

    2004-06-01

    Transthoracic Doppler echocardiography provides noninvasive measurements of coronary blood flow in the left anterior descending coronary artery (LAD). This method has the potential to show the effects of acute changes in loading conditions on blood flow. Coil closure of patent ductus arteriosus (PDA) is a model of acute changes in blood pressure and left ventricular (LV) preload that influences coronary blood flow. We applied this technique to assess the coronary blood flow changes for patients with PDA before and immediately after PDA coil closure. We examined 9 patients (1.8 +/- 1.1 years) with simple PDA and 8 age-matched healthy children. LV dimensions and LV mass were measured. Maximum peak flow velocity and flow volume in the LAD were measured. Pulmonary to systemic flow ratios (Qp/Qs) were obtained by cardiac catheterization. After PDA coil closure, LV end-diastolic dimension decreased, and systolic and diastolic blood pressures increased significantly. The maximum peak flow velocity, LAD flow volume, and the ratio of LAD flow volume to LV mass increased significantly. The changes in maximum peak flow velocity and the ratio of LAD flow volume to LV mass (F/M) correlated positively with the changes in diastolic pressure and Qp/Qs. In 5 patients who had Qp/Qs > 1.5, the mean F/M was significantly lower compared with control subjects, but they increased to normal values after coil closure of PDA. PDA coil closure increases diastolic pressure and decreases Qp/Qs, resulting in improvement of myocardial perfusion. These findings provide new insights into the relationship between cardiac function and coronary circulation in pediatric patients with heart diseases associated with PDA.

  11. Tomographic myocardial perfusion scintigraphy in children with Kawasaki disease

    International Nuclear Information System (INIS)

    Spielmann, R.P.; Nienaber, C.A.; Hausdorf, G.; Montz, R.

    1987-01-01

    Myocardial infarction and stenotic coronary lesions are serious late complications in children with Kawasaki disease. For the noninvasive assessment of myocardial perfusion, dipyridamole-redistribution 201 Tl emission computed tomography (ECT) was performed in seven children (age 2 8/12-8 7/12 yr) 3-20 mo after the acute stage of the disease. In all patients, coronary aneurysms had been demonstrated by cross-sectional echocardiography. The scintigrams of six children showed no significant regional reduction of myocardial thallium uptake. These children had remained asymptomatic since the acute stage of Kawasaki disease. Persistent and transient thallium defects were present in one child with documented myocardial infarction. For this patient, obstruction of corresponding coronary vessels was confirmed by contrast angiography. It is suggested, that 201 Tl ECT after dipyridamole-induced vasodilation may be used as a safe alternative to invasive coronary angiography for follow-up investigations in patients with Kawasaki disease

  12. Prediction of coronary artery bypass graft flow

    International Nuclear Information System (INIS)

    Tamiya, Eiji; Hada, Yoshiyuki; Asano, Ken-ichi; Iio, Masahiro.

    1991-01-01

    To predict the coronary artery bypass graft (CABG) flow based on the time density curve (TDC) obtained from the digital subtraction aortograms (DSA), we developed a pulsatile CABG model (perfusion pressure 60,130 mmHg, pulse rate 53,126/min, cardiac output 3-7 l/min, diameter of the graft 2.1∼6.0 mm). After positioning the regions of interest (ROI), we injected contrast medium(5∼40 ml/sec, 5∼40 ml) into the outlet conduit. Concerning the TDCs, we calculated appearance time (Ta), peak densities (Dp), peak time (Tp), disappearance time (Td), integral of TDC, ΔTp (difference of Tp between two ROI) and ΔTa (difference of Ta between two ROI). Perfusion pressure, graft flow and output curve were similar to those of patients with CABG. Ta, Tp, Td, and ΔTp were affected by both the injection rate and the volume of the contrast medium; while Dp and the TDC integral were only affected by the latter parameter. Under the same conditions of contrast medium injection, the TDC depended strongly on graft flow, diameter of the graft, output and pulse rate. 21.6+0.92π·d 2 /4·Δ1/ΔTp·60 provided the most accurate estimation of CABG flow (r=0.865, p<0.01). We conclude that densitometric analysis of DSA may be useful in the prediction of CABG flow. (author)

  13. Dipyridamole stress myocardial perfusion by computed tomography in patients with left bundle branch block

    OpenAIRE

    Cabeda, Est?van Vieira; Falc?o, Andr?a Maria Gomes; Soares Jr., Jos?; Rochitte, Carlos Eduardo; Nomura, C?sar Higa; ?vila, Luiz Francisco Rodrigues; Parga, Jos? Rodrigues

    2015-01-01

    Abstract Background: Functional tests have limited accuracy for identifying myocardial ischemia in patients with left bundle branch block (LBBB). Objective: To assess the diagnostic accuracy of dipyridamole-stress myocardial computed tomography perfusion (CTP) by 320-detector CT in patients with LBBB using invasive quantitative coronary angiography (QCA) (stenosis ≥ 70%) as reference; to investigate the advantage of adding CTP to coronary computed tomography angiography (CTA) and comp...

  14. Detection of myocardial ischemia of hypertrophic cardiomyopathy with gated 99Tcm-MIBI myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Jia Peng; Guo Wanhua; Du Minghua; Gao Ling

    2010-01-01

    Objective: To evaluate the value of gated 99 Tc m -methoxyisobutylisonitrile (MIBI) myocardial perfusion imaging in detection of myocardial ischemia in hypertrophic cardiomyopathy. Methods: Sixty-nine patients with clinically proven hypertrophic cardiomyopathy were divided into 2 groups using coronary angiogram as 'gold standard': positive group (n=19, narrowing ≥ 50%) and negative group (n=50, narrowing 99 Tc m -MIBI myocardial perfusion imaging was performed and positive in all 69 patients (41 males, 28 females, aged 35-75 years). Comparative analysis between the two groups was carried out using t-test. Results: In the positive group, reversible and irreversible perfusion defects were detected in 9 and 10 patients, respectively. Left ventricular ejection fraction (LVEF) increased to (69.1 ± 2.8)% in 8 patients and decreased to (42.8 ± 2.1)% in 11 patients. In the negative group, reversible and irreversible perfusion defects were found in 37 and 13 patients, respectively. LVEF increased to (70.8 ± 4.0)% in 38 patients and decreased to (48.9 ± 2.7)% in 12 patients. The values of ischemic area, severity and extent of perfusion defect, and LVEF were significantly different between the two groups (t=9.28, 16.51, 2.65; P 99 Tc m -MIBI myocardial perfusion imaging is valuable in assessing patients with hypertrophic cardiomyopathy. Detection for the presence or absence of coexisting coronary artery disease and myocardial ischemia has an important prognostic indication and management indication for these patients. (authors)

  15. Selective intra-coronary injection of sup(99m)Tc-labelled microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Degeorges, M; Roucayrol, J C; Comet, M; Sol, C; Devaux, J Y; Delebarre, P; d' Izarn, J J [Hopital Cochin, 75 - Paris (France)

    1977-02-01

    A technique of myocardial perfusion imaging and a clinical experience with this technique in 83 patients with coronary artery disease are described. sup(99m)Tc-labelled microspheres were injected directly into one or both major coronary arteries, at the time of coronary arteriography. Microspheres with a mean diameter of 15..mu.. were used. Myocardial infarcts resulting from small vessel occlusions were detected by this technique. The results were compared to those obtained with coronary arteriography and with scintigraphy using /sup 201/Tl or /sup 131/Cs administered intravenously. Certain conclusions regarding coronary arterial injection can be drawn from this comparison. The possibility of irregularities of microsphere distribution after intra-coronary injection must be considered.

  16. Frequency and severity of myocardial perfusion abnormalities using Tc-99m MIBI SPECT in cardiac syndrome X

    International Nuclear Information System (INIS)

    Saghari, Mohsen; Assadi, Majid; Eftekhari, Mohammad; Yaghoubi, Mohammad; Fard-Esfahani, Armaghan; Malekzadeh, Jan-Mohammad; Sichani, Babak Fallhi; Beiki, Davood; Takavar, Abbas

    2006-01-01

    Cardiac syndrome X is defined by a typical angina pectoris with normal or near normal (stenosis <40%) coronary angiogram with or without electrocardiogram (ECG) change or atypical angina pectoris with normal or near normal coronary angiogram plus a positive none-invasive test (exercise tolerance test or myocardial perfusion scan) with or without ECG change. Studies with myocardial perfusion imaging on this syndrome have indicated some abnormal perfusion scan. We evaluated the role of myocardial perfusion imaging (MPI) and also the severity and extent of perfusion abnormality using Tc-99m MIBI Single Photon Emission Computed Tomography (SPECT) in these patients. The study group consisted of 36 patients with cardiac syndrome X. The semiquantitative perfusion analysis was performed using exercise Tc-99m MIBI SPECT. The MPI results were analyzed by the number, location and severity of perfusion defects. Abnormal perfusion defects were detected in 13 (36.10%) cases, while the remaining 23 (63.90%) had normal cardiac imaging. Five of 13 (38.4%) abnormal studies showed multiple perfusion defects. The defects were localized in the apex in 3, apical segments in 4, midventricular segments in 12 and basal segments in 6 cases. Fourteen (56%) of all abnormal segments revealed mild, 7(28%) moderate and 4 (16%) severe reduction of tracer uptake. No fixed defects were identified. The vessel territories were approximately the same in all subjects. The Exercise treadmill test (ETT) was positive in 25(69%) and negative in 11(30%) patients. There was no consistent pattern as related to the extent of MPI defects or exercise test results. Our study suggests that multiple perfusion abnormalities with different levels of severity are common in cardiac syndrome X, with more than 30 % of these patients having at least one abnormal perfusion segment. Our findings suggest that in these patients microvascular angina is probably more common than is generally believed

  17. Transthoracic Doppler echocardiography compared with positron emission tomography for assessment of coronary microvascular dysfunction

    DEFF Research Database (Denmark)

    Michelsen, Marie Mide; Mygind, Naja Dam; Pena, Adam

    2017-01-01

    stenosis at invasive coronary angiography, TTDE CFVR by dipyridamole induced stress and MBFR by rubidium-82 PET with adenosine was successfully measured in 107 subjects. Repeatability of TTDE CFVR was assessed in 10 symptomatic women and in 10 healthy individuals. RESULTS: MBFR was systematically higher...... by time-interval between examinations. Results were similar when adjusting for rate pressure product or focusing on perfusion of the left anterior descending artery region. Limits of agreement (CI) for repeated CFVR in 10 healthy individuals and in 10 women with angina was 0.44 (0.21;0.68) and 0.48 (0...

  18. Regional cerebral perfusion in cardiovascular reflex syncope

    International Nuclear Information System (INIS)

    Toeyry, J.P.; Kuikka, J.T.; Laensimies, E.A.

    1997-01-01

    Little is known about the regional cerebral perfusion in subjects with presyncope or syncope, and the impact that autonomic nervous dysfunction has on it. Seven subjects with cardiovascular vasodepressor reflex syncope were studied. A baseline test was performed with the patients standing in the 70 upright position, while the passive head-up tilt table test with and without isoprenaline infusion was employed for provocation. Regional cerebral perfusion was assessed by means of single-photon emission tomography with technetium-99m labelled V-oxo-1,2-N,N 1 -ethylenedylbis-l-cysteine diethylester (baseline, and during blood pressure decline in the provocation test) and the autonomic nervous function by means of spectral analysis of heart rate variability (baseline, and before blood pressure decline in the provocation test). Every subject showed an abrupt decline in blood pressure in the provocation test (five with presyncope and two with syncope). The systolic and diastolic blood pressures decreased significantly (P<0.001) between the baseline and the provocation study time points (radiopharmaceutical injection and lowest systolic blood pressure). Mean cerebral perfusion as average count densities decreased upon provocation as compared with baseline (190±63 vs 307±90 counts/voxel, respectively, P=0.013). Hypoperfusion was most pronounced in the frontal lobe. These results suggest that cerebral perfusion decreases markedly during presyncope or syncope with systemic blood pressure decline in subjects with cardiovascular vasodepressor syncope. Furthermore, the autonomic nervous function remains unchanged before the systemic blood pressure decline. (orig.). With 3 figs., 2 tabs

  19. Correlation of the myocardial perfusion corrected by attenuation with the coronariography. Preliminary results; Correlacion de la perfusion miocardica corregida por atenuacion con la coronariografia

    Energy Technology Data Exchange (ETDEWEB)

    Garcia C, S.E.; Garcia O, R. [Servicio de Medicina Nuclear, Centro Medico ABC, Campis Observatorio, IAP (Mexico)

    2005-07-01

    The attenuation that suffers the radiation in the soft tissues of the hinders the appropriate interpretation of the myocardial perfusion studies, for what have been implemented attenuation correction systems to reduce the attenuation for soft tissues and to provide myocardial perfusion images more accurate in the diagnosis of coronary illness. The objective was to evaluate the utility of an attenuation correction system (with source of Gadolinium 153) to minimize the devices that look like true defects of myocardial perfusion, caused by soft tissues (mammary tissue, thoracic wall, abdomen, left hemi diaphragm), and to compare those interpretations of the studies with the interpretations of the corresponding coronariographies. The method consists of 95 electronic files which were revised with the concept of heart catheterization, being identified 20 patients from the masculine sex to those that underwent coronariography among May 1999 and December 2002, and that they had study of myocardial perfusion in a maximum period of 3 months foresaw to the invasive procedure. (Author)

  20. Use of corrosion casting techniques to evaluate coronary collateral vessels and anastomoses in hearts of canine cadavers.

    Science.gov (United States)

    Noestelthaller, Arne; Probst, Alexander; Koenig, Horst E

    2005-10-01

    To study and investigate branching patterns of the canine coronary arteries and collateral circulation by use of corrosion casting techniques. 31 hearts obtained from cadavers of clinically normal dogs of various ages and breeds and of either sex. 3-dimensional reproduction of coronary arteries was achieved by postmortem injection and perfusion with casting materials into the aortic sinus via the ascending aorta. Perfused hearts were macerated and carefully irrigated; the air-dried specimens were examined macroscopically and with a magnifying headset. Collateral arteries and inter- and intra-arterial anastomoses were successfully detected in 8 corrosion cast specimens. In total, 9 coronary collateral arteries and 3 interarterial anastomoses were found. Our finding of coronary collateral arteries in canine hearts is in agreement with recent findings in coronary flow study. On the basis of our results, vasodilation treatment to improve collateral vessel remodeling in dogs with myocardial dysfunction may be warranted.

  1. Determination of improved myocardial perfusion after aortocoronary bypass surgery by exercise 81Rb scintigraphy

    International Nuclear Information System (INIS)

    Lurie, A.J.; Salel, A.F.; Berman, D.S.; DeNardo, G.L.; Hurley, E.J.; Mason, D.T.

    1976-01-01

    Practical and noninvasive means are needed for evaluating efficacy of coronary bypass surgery (CBS) in improving blood flow (CBF) to ischemic myocardium in coronary patients. Revascularization was assessed in 15 patients by pre- and post-CBS rest and exercise rubidium-81 myocardial images with a scintillation camera equipped with pinhole collimator and high-energy shield. Ischemic areas were detected by decreased 81 Rb activity after exercise compared to rest. Before CBS all patients had exercise angina (EA), positive treadmill ECG (TECG), and abnormal exercise 81 Rb scans. After CBS all 15 patients had increased physical activity before angina or completion of treadmill exercise with increased heart rate-blood pressure product (HRBP) (+63 +/- 3.2 x 10(2) bpm - mm Hg) in 14 of 15 patients indicating increased CBF; four had positive TECG, and five had EA. The increased HRBP in 14 patients was associated with improved post-CBS exercise 81 Rb scans: six had normal patterns while nine were improved with less ischemic patterns. Further, lack of angina and increased exercise tolerance correlated closely with increased 81 Rb myocardial perfusion. Thus pre- and postoperative rest and exercise 81 Rb scintigraphy gives an accurate, noninvasive, objective approach for evaluation of CBF following CBS and demonstrates the usefulness of this revascularization procedure in coronary patients

  2. Myocardial ischemia in severe aortic regurgitation despite angiographically normal coronary arteries

    International Nuclear Information System (INIS)

    Aksoy, S.; Cam, N.; Guney, M.R.; Gurkan, U.; Oz, D.; Poyraz, E.; Eksik, A.; Agirbasli, M.

    2012-01-01

    Patients with severe aortic regurgitation frequently present with angina pectoris. The exact pathophysiology for angina in aortic regurgitation is not clear. Left ventricular hypertrophy and myocardial blood supply-demand mismatch have been the suggested mechanisms to explain ischemia. However, no conclusive clinical study exists to define the incidence of ischemia in patients with severe aortic regurgitation and normal coronary arteries. We, therefore, investigated the frequency of myocardial ischemia in relation to left ventricular hypertrophy or dilatation in patients with severe aortic regurgitation and normal coronary arteries. We reviewed the medical records of all patients (n=311) with aortic valve replacement due to aortic regurgitation between 2007 and 2010. We selected subjects with normal coronary arteries (n=182) for the study purpose, and we identified 35 patients who underwent myocardial perfusion scintigraphy prior to the coronary angiography (19 female and 16 male subjects; age 45.0±8.9 years). Left ventricular hypertrophy and dilatation were detected in 9 (26%) and 5 (14%) patients, respectively. Myocardial perfusion scintigraphy showed evidence of ischemia in 10 (29%) patients with normal coronary arteries. The presence of ischemia did not relate to the presence of left ventricular hypertrophy and/or dilatation. As a potential mechanism, aortic regurgitation causes backflow of blood from the aorta into the left ventricle, hence disturbs coronary flow dynamics. In conclusion, myocardial ischemia is common (nearly one-third) among patients with severe aortic regurgitation even in the absence of coronary obstruction, left ventricular hypertrophy and/or dilatation. (author)

  3. Comparison of adenosine and treadmill exercise thallium-201 stress tests for the detection of coronary artery disease

    International Nuclear Information System (INIS)

    Abe, Shinya; Takeishi, Yasuchika; Chiba, Junya; Ikeda, Kozue; Tomoike, Hitonobu

    1993-01-01

    To determine the clinical usefulness of adenosine Tl-201 imaging for the evaluation of coronary artery disease, 22 patients with suspected coronary artery disease who underwent adenosine and exercise Tl-201 single photon emission computed tomography (SPECT) were studied. The peak levels of heart rate (83 vs 123 bpm, p<0.001), systolic blood pressure (124 vs 164 mmHg, p<0.001), diastolic blood pressure (70 vs 86 mmHg, p<0.01) and rate pressure products (10220 vs 20410 bpm x mmHg, p<0.001) were markedly smaller during adenosine infusion than during exercise. Segmental agreements between adenosine and exercise tests were 90% (218 of 242 segments) regarding the presence of perfusion defects and 89% (215 of 242 segments) regarding the presence of redistribution. Regional Tl-201 uptake (r=0.85, p<0.001) and the extent (r=0.75, p<0.001) and intensity (r=0.83, p<0.001) of Tl-201 defects during adenosine testing were closely correlated with those of exercise testing. Adenosine and exercise tests showed similar sensitivities for the identification of individual coronary stenosis (85% vs 78%). However, in patients who were unable to perform adequate exercise (maximal heart rate<120 bpm), the sensitivity of adenosine imaging tended to be higher than that of exercise imaging (92% vs 69%, p=0.07). Adenosine Tl-201 imaging is an alternative to the exercise test for assessing the severity and loci of coronary artery disease, especially in patients who are unable to perform adequate physical exercise. (author)

  4. Direct effects of smoking on the heart: silent ischemic disturbances of coronary flow

    International Nuclear Information System (INIS)

    Deanfield, J.E.; Shea, M.J.; Wilson, R.A.; Horlock, P.; de Landsheere, C.M.; Selwyn, A.P.

    1986-01-01

    Cigarette smoking is strongly associated with ischemic heart disease and acute coronary events. The effect of smoking a single cigarette on regional myocardial perfusion was studied in 13 chronic smokers with typical stable angina pectoris using positron emission tomography and rubidium-82 ( 82 Rb). Findings were compared with the effects of physical exercise. After exercise, 8 patients (61%) had angina, ST depression and abnormal regional myocardial perfusion. Uptake of 82 Rb increased from 49 +/- 8 to 60 +/- 7 in remote myocardium, but decreased from 46 +/- 3 to 37 +/- 5 in an ischemic area. The remaining 5 patients (39%) had homogeneous increases in 82 Rb uptake without angina or ST depression. After smoking, 6 of the 8 patients with positive exercise test responses had a decrease in 82 Rb uptake, from 47 +/- 3 to 35 +/- 6 in the same segment of myocardium affected during exercise. However, in contrast to exercise, the events during smoking were largely silent. The absolute decreases in regional 82 Rb uptake after smoking occurred at significantly lower levels of myocardial oxygen demand than after exercise. This suggests that an impairment of coronary blood supply is responsible. Thus, in smokers with coronary artery disease, each cigarette can cause profound silent disturbances of regional myocardial perfusion that are likely to occur frequently during daily life. Such repeated insults may represent an important mechanism linking smoking with coronary events

  5. Assessment of myocardial collateral circulation by intracoronary injection of radioactive microspheres and selective coronary angiography

    International Nuclear Information System (INIS)

    Uhde, W.

    1986-01-01

    In 46 patients selective coronary angiography was performed followed by selective coronary perfusion scintigraphy and a comparative assessment was made of the contralateral coronary collateral circulation. Intracoronary injection of radioactively marked imcrospheres resulted in the detection of microcirculatory processes and made it possible to evaluate the relative efficiency of coronary collaterals. This in turn meant a low-risk supplement and extension of the findings of coronary angiography. This holds particularly true for the area of the left ventricular myocardium. (author)

  6. Counteracting negative venous line pressures to avoid arterial air bubbles: an experimental study comparing two different types of miniaturized extracorporeal perfusion systems.

    Science.gov (United States)

    Aboud, Anas; Mederos-Dahms, Hendrikje; Liebing, Kai; Zittermann, Armin; Schubert, Harald; Murray, Edward; Renner, Andre; Gummert, Jan; Börgermann, Jochen

    2015-05-29

    Because of its low rate of clinical complications, miniaturized extracorporeal perfusion systems (MEPS) are frequently used in heart centers worldwide. However, many recent studies refer to the higher probability of gaseous microemboli formation by MEPS, caused by subzero pressure values. This is the main reason why various de-airing devices were developed for today's perfusion systems. In the present study, we investigated the potential benefits of a simple one-way-valve connected to a volume replacement reservoir (OVR) for volume and pressure compensation. In an experimental study on 26 pigs, we compared MEPS (n = 13) with MEPS plus OVR (n = 13). Except OVR, perfusion equipment was identical in both groups. Primary endpoints were pressure values in the venous line and the right atrium as well as the number and volume of air bubbles. Secondary endpoints were biochemical parameters of systemic inflammatory response, ischemia, hemodilution and hemolysis. One animal was lost in the MEPS + OVR group. In the MEPS + OVR group no pressure values below -150 mmHg in the venous line and no values under -100 mmHg in right atrium were noticed. On the contrary, nearly 20% of venous pressure values in the MEPS group were below -150 and approximately 10% of right atrial pressure values were below -100 mmHg. Compared with the MEPS group, the bubble counter device showed lower numbers of arterial air bubbles in the MEPS + OVR group (mean ± SD: 13444 ± 5709 vs. 1 ± 2, respectively; p pressures and to reduce the number and volume of arterial air bubbles. This approach may lead to a lower rate of neurological complications.

  7. GAMMAGRAFÍA DE PERFUSIÓN MIOCÁRDICA EN MUJERES POSMENOPÁUSICAS CON ANGINA Y CORONARIAS EPICÁRDICAS ANGIOGRÁFICAMENTE NORMALES / Myocardial perfusion scintigraphy in postmenopausal women with angina and angiographically normal epicardial coronary

    Directory of Open Access Journals (Sweden)

    Sherien Sixto Fernández

    2011-03-01

    Full Text Available Introduction and Objectives: Microvascular angina is common in postmenopausal women. Myocardial ischemia was induced by stress testing, and reports have been published about the relationship between endothelial dysfunction and myocardial perfusion. The objective of this research was to determine whether myocardial ischemia can be evidenced by abnormalities in perfusion and function, as detected by myocardial scintigraphy in women with typical angina, normal coronary angiography and endothelial dysfunction. Methods: 59 women underwent lipid and endothelial function measurements by brachial artery ultrasound, in addition, a 24-hour ECG study (Holter. During the scintigraphy a stress-rest protocol was applied. Patients were divided into two groups according to presence (group I or absence (group II of myocardial perfusion defects. Results: 21 patients showed perfusion defects. 57 % of group I exhibited greater endothelial dysfunction. Only twelve patients showed reversible perfusion defects, and 75 % of the cases was associated with a reduction of post-stress left ventricular ejection fraction, greater than 5 %, and regional abnormalities of wall motion. Three patients in group I showed evidence of ischemia compared with four in Group II. Conclusions: The stress-induced ischemia was associated with a reduced post-stress ejection fraction and endothelial dysfunction in the studied women, and no ischemic changes in the Holter were found.

  8. Deficiency of sex hormones does not affect 17-ß-estradiol-induced coronary vasodilation in the isolated rat heart.

    Science.gov (United States)

    Santos, R L; Lima, J T; Rouver, W N; Moysés, M R

    2016-01-01

    The relaxation of coronary arteries by estrogens in the coronary vascular beds of naive and hypertensive rats has been well described. However, little is known about this action in gonadectomized rats. We investigated the effect of 17-ß-estradiol (E2) in coronary arteries from gonadectomized rats, as well as the contributions of endothelium-derived factors and potassium channels. Eight-week-old female and male Wistar rats weighing 220-300 g were divided into sham-operated and gonadectomized groups (n=9-12 animals per group). The baseline coronary perfusion pressure (CPP) was determined, and the vasoactive effects of 10 μM E2 were assessed by bolus administration before and after endothelium denudation or by perfusion with NG-nitro-L-arginine methyl ester (L-NAME), indomethacin, clotrimazole, L-NAME plus indomethacin, L-NAME plus clotrimazole or tetraethylammonium (TEA). The CPP differed significantly between the female and sham-operated male animals. Gonadectomy reduced the CPP only in female rats. Differences in E2-induced relaxation were observed between the female and male animals, but male castration did not alter this response. For both sexes, the relaxation response to E2 was, at least partly, endothelium-dependent. The response to E2 was reduced only in the sham-operated female rats treated with L-NAME. However, in the presence of indomethacin, clotrimazole, L-NAME plus indomethacin or L-NAME plus clotrimazole, or TEA, the E2 response was significantly reduced in all groups. These results highlight the importance of prostacyclin, endothelium-derived hyperpolarizing factor, and potassium channels in the relaxation response of coronary arteries to E2 in all groups, whereas nitric oxide may have had an important role only in the sham-operated female group.

  9. Stenosis differentially affects subendocardial and subepicardial arterioles in vivo.

    Science.gov (United States)

    Merkus, D; Vergroesen, I; Hiramatsu, O; Tachibana, H; Nakamoto, H; Toyota, E; Goto, M; Ogasawara, Y; Spaan, J A; Kajiya, F

    2001-04-01

    The presence of a coronary stenosis results primarily in subendocardial ischemia. Apart from the decrease in coronary perfusion pressure, a stenosis also decreases coronary flow pulsations. Applying a coronary perfusion system, we compared the autoregulatory response of subendocardial (n = 10) and subepicardial (n = 12) arterioles (production with N(G)-monomethyl-L-arginine abrogated the effect of the stenosis on flow. We conclude that the decrease in pressure caused by a stenosis in vivo results in a larger decrease in diameter of the subendocardial arterioles than in the subepicardial arterioles, and furthermore stenosis selectively decreases the dilatory response of subendocardial arterioles. These two findings expand our understanding of subendocardial vulnerability to ischemia.

  10. Perfusion imaging using rubidium-82 ((82)Rb) PET in rats with myocardial infarction

    DEFF Research Database (Denmark)

    Clemmensen, Andreas Ettrup; Ghotbi, Adam Ali; Bodholdt, Rasmus Poul

    2017-01-01

    Assessing myocardial perfusion using 82Rb-PET is emerging as a valuable clinical tool.1,2 The rapid decay (T½ = 76 s) allows for absolute quantification of both rest and stress perfusion within 30 minutes. In addition to evaluation of epicardial disease with perfusion defects, also evaluation...... of balanced coronary and small vessel disease is possible. For further evaluation of how 82Rb-PET can be used clinically, pre-clinical application of the method would be valuable. However, so far no data on the use of 82Rb-PET in small animals have been published nor has the use of 82Rb-PET, to the best...

  11. Electrocardiographic left ventricular hypertrophy without echocardiographic abnormalities evaluated by myocardial perfusion and fatty acid metabolic imaging

    International Nuclear Information System (INIS)

    Narita, Michihiro; Kurihara, Tadashi

    2000-01-01

    The pathophysiologic process in patients with electrocardiographic left ventricular hypertrophy with ST, T changes but without echocardiographic abnormalities was investigated by myocardial perfusion imaging and fatty acid metabolic imaging. Exercise stress 99m Tc-methoxy-isobutyl isonitrile (MIBI) imaging and rest 123 I-beta-methyl-p-iodophenyl pentadecanoic acid (BMIPP) imaging were performed in 59 patients with electrocardiographic hypertrophy including 29 without apparent cause including hypertension and echocardiographic hypertrophy, and 30 with essential hypertension. Coronary angiography was performed in 6 patients without hypertension and 4 with hypertension and biopsy specimens were obtained from the left ventricular apex from 6 patients without hypertension. Myocardial perfusion and 123 I-BMIPP images were classified into 3 types: normal, increased accumulation of the isotope at the left ventricular apex (high uptake) and defect. Transient perfusion abnormality and apical defect observed by 123 I-BMIPP imaging were more frequent in patients without hypertension than in patients with hypertension (32% vs. 17%, p=0.04671 in perfusion; 62% vs. 30%, p=0.0236 in 123 I-BMIPP). Eighteen normotensive patients with apical defect by 123 I-BMIPP imaging included 3 of 10 patients with normal perfusion at exercise, 6 of 10 patients with high uptake and 9 of 9 patients with perfusion defect. The defect size revealed by 123 I-BMIPP imaging was greater than that of the perfusion abnormality. Coronary stenoses were not observed and myocardial specimens showed myocardial disarray with hypertrophy. Moreover, 9 patients with hypertension and apical defects by 123 I-BMIPP showed 3 different types of perfusion. Many patients without hypertension show a pathologic process similar to hypertrophic cardiomyopathy. Perfusion and 123 I-BMIPP imaging are useful for the identification of these patients. (author)

  12. Large right ventricular sinusoids in an infant with aorta-left ventricular tunnel and proximal right coronary artery atresia.

    Science.gov (United States)

    Chen, Peter C; Spinner, Joseph A; Heinle, Jeffrey S

    2018-07-01

    We report a 1-month-old infant diagnosed with an aorta-left ventricular tunnel, ventricular septal defect, and right coronary atresia with right ventricular sinusoids. The patient's anatomy and physiology did not indicate right-ventricular-dependent coronary circulation, and therefore right ventricular decompression could be performed without compromising coronary perfusion during surgical correction. A detailed understanding of the coronary anatomy is critical in managing this defect when coronary anomalies are present.

  13. Effects of dipyridamole and aminophylline on hemodynamics, regional myocardial blood flow and thallium-201 washout in the setting of a critical coronary stenosis

    International Nuclear Information System (INIS)

    Granato, J.E.; Watson, D.D.; Belardinelli, L.; Cannon, J.M.; Beller, G.A.

    1990-01-01

    Experiments were performed to characterize the interaction of intravenous dipyridamole and aminophylline on thallium-201 transport kinetics, regional myocardial blood flow and systemic hemodynamics in the presence of a critical coronary artery stenosis. In 12 dogs with a critical left anterior descending coronary artery stenosis, arterial pressure decreased from a mean value (+/- SEM) of 107 +/- 6 to 94 +/- 3 mm Hg and distal left anterior descending artery pressure decreased from 70 +/- 7 to 55 +/- 4 mm Hg after intravenous administration of dipyridamole. In the left anterior descending perfusion zone, the endocardial/epicardial flow ratio decreased from 0.70 to 0.36 and the intrinsic thallium washout rate was significantly prolonged. Intravenous aminophylline reversed the dipyridamole-induced systemic hypotension and transmural coronary steal and restored the thallium washout rate to baseline values. In six other dogs, aminophylline alone resulted in no alterations in systemic and coronary hemodynamics or regional myocardial blood flow. As expected, dipyridamole-induced vasodilation and coronary steal were prevented by aminophylline pretreatment. These data show that in a canine model of partial coronary stenosis, systemic hypotension, adverse regional flow effects and prolonged thallium-201 washout consequent to intravenously administered dipyridamole are promptly reversed by intravenous aminophylline administration. Aminophylline alone had no significant hemodynamic and coronary flow effects. This study provides further insight into the altered thallium kinetics occurring as a consequence of dipyridamole-induced vasodilation and suggests that the prompt reversal of symptoms and signs of ischemia with aminophylline in patients receiving intravenous dipyridamole for clinical imaging studies probably reflects the reversal of transmural coronary steal

  14. The usefulness of preoperative exercise stress myocardial single photon emission CT with thallium-201 to predict the responses to coronary revascularization

    International Nuclear Information System (INIS)

    Narita, Michihiro; Kurihara, Tadashi; Murano, Kenichi; Usami, Masahisa; Minamino, Takazoh; Katoh, Osamu; Higashino, Yorihiko.

    1989-01-01

    To evaluate the usefulness of preoperative exercise stress (Ex) myocardial single photon emission CT (SPECT) with thallium-201 to predict the responses to coronary revascularization (CRV), Ex-SPECT's were obtained in 42 patients with coronary artery disease (CAD). In 34 patients angioplasty was performed and in 18 patients coronary bypass surgery was undergone. Before and after CVR, Ex-SPECT's were obtained both at immediately after Ex (Initial) and 3 hours later (RD) by the rotating gamma camera. Initial images before CRV showed definite perfusion defects (+3) in 76 myocardial segments. Perfusion abnormalities at RD images were graded into (+3 to 0) by visual interpretation. '+3' indicated fixed defect and '0' indicated no perfusion abnormality. At RD images 17 segments showed fixed defect and 59 segments showed improved perfusion more than one grade. After CRV, all 59 segments with improved perfusion at RD images showed improvement of perfusion in comparison with initial images before CRV. Out of 17 segments with fixed defect before CRV, 14 segments showed perfusion defect with +3, while 3 segments showed improved perfusion after CRV. These 3 segments had ECG evidence of myocardial infarction. In these 3 segments, Ex-SPECT's before CRV showed abnormally low myocardial Tl washout rate (WOR) despite they indicated fixed defect visually. On the contrary, other 14 segments with fixed defect showed normal WOR before CRV. In conclusion, visually interpreted Ex-SPECT's before CRV predict the myocardial perfusion after CRV in most of cases. In a small number (especially infarction segments) Ex-SPECT's before CRV cannot predict the improvement of myocardial perfusion after CRV by visual inspection, but WOR abnormality before CRV is useful to prospect their results. (author)

  15. Acetylcholine versus cold pressor testing for evaluation of coronary endothelial function.

    Directory of Open Access Journals (Sweden)

    Ahmed AlBadri

    Full Text Available Assessment of coronary endothelial function with intracoronary acetylcholine (IC-Ach provides diagnostic and prognostic data in patients with suspected coronary microvascular dysfunction (CMD, but is often not feasible due in part to the time and expertise needed for pharmacologic mixing. Cold pressor testing (CPT is a simple and safe stimulus useful for either invasive or non-invasive endothelial function testing and myocardial perfusion imaging but has not been specifically evaluated among symptomatic women with signs of ischemic heart disease (IHD who have no obstructive coronary artery disease (CAD.163 women with signs and symptoms of IHD and no obstructive CAD from the NHLBI- Women's Ischemia Syndrome Evaluation-Coronary Vascular Dysfunction (WISE-CVD study underwent coronary reactivity testing with a Doppler flow wire (FloWire® Volcano, San Diego, CA in the proximal left anterior descending artery. Coronary artery diameter and coronary blood flow (CBF assessed by core lab using QCA before and after IC-Ach (18.2 μg/ml infused over 3 minutes and during CPT.Mean age was 55 ± 12 years. Rate pressure product (RPP in response to IC-Ach did not change (baseline to peak, P = 0.26, but increased during CPT (363±1457; P = 0.0028. CBF in response to CPT was poorly correlated to IC-Ach CBF. Change in coronary artery diameter after IC-Ach correlated with change after CPT (r = 0.59, P<0.001. The correlation coefficient was stronger in subjects with coronary dilation to IC-Ach (r = 0.628, P<0.001 versus those without dilation (r = 0.353, P = 0.002, suggesting that other factors may be important to this relationship when endothelium is abnormal.In women with no obstructive CAD and suspected CMD, coronary diameter changes with IC-Ach and CPT are moderately-well correlated suggesting that CPT testing may be of some use, particularly among patients with normal endothelial function, however, not an alternative to IC-Ach for diagnosis of coronary

  16. Selective coronary scintigraphy

    International Nuclear Information System (INIS)

    Gambini, D.-J.

    1975-01-01

    Isotopic techniques occupy a leading place amongst examinations practicable on coronary patients because of their reliability and the safety and simplicity of their use. The present work reviews the possible applications of selective coronary scintigraphy in pathology. After a brief discussion on scintigraphy, isotopic techniques for myocardium research, coronarography and other methods to study local myocardium perfusion the theoretical bases for the use of the exploration are studied, the techniques and methods employed are reported and the results discussed. Coronary scintigraphy consists of selective injection in the two coronary arteries previously catheterized during a coronarography, of two different populations of microspheres labelled with two physically short-lived indicators: 15μ 99m Tc-labelled serumalbumin microspheres, 10 to 15μ In-labelled siderophiline microspheres. Various studies have shown the complete harmlessness of the exploration when certain precautions are taken regarding the size and number of the spheres. The microspheres disperse into the downstream arterial territory proportionally to the number of capillaries present in the different parts of the irrigated region, and are temporarily stopped in the precapillaries. The preparation of the different images needed to interpret the Face and OAG examination for the left coronary, then for the right coronary, is carried out at the end of the coronarography and lasts about 45 minutes. It is also possible by selective injection in the aorta-coronary bridges to judge their functional condition by observation of the regions they irrigate. 56 patients of the Necker hospital cardiological clinic have been examined [fr

  17. Influence of revascularization on myocardial perfusion, metabolism and function evaluated with I-123-IPPA

    International Nuclear Information System (INIS)

    Kropp, J.; Krois, M.; Eichhorn, B.; Feske, W.; Likungu, J.; Kirchhoff, P.J.; Luederitz, B.; Biersack, H.J.; Knapp, F.F. Jr.

    1993-01-01

    Patients with coronary artery disease (CAD) were investigated with sequential SPECT-scintigraphy after administration of 200 MBq of 15-(p-[I-123]iodophenyl)pentadecanoic acid (IPPA) at peak submaximal exercise. Twenty patients underwent coronary angioplasty (PTCA) from which 14 had control coronary arteriography (CA) and left ventricular cineventriculography (LVCV). Nineteen pts underwent bypass graft surgery (ACB) and stress sonagraphy. Semi-quantification of uptake (Up related to perfusion) and turnover (Tr) was obtained by segmental comparison of oblique slices. About 90% of the reperfused myocardial segments in the PTCA-group and 76% in the ACB-group showed an improvement of uptake after therapy (RUp). Of these, 50% and 66% exhibited increased turnover (RTr) after PTCA or ACB. Pathologic RTr was highly correlated with regional wall motion abnormalities after therapy in both groups. In the ACB-group presence of improvement of RTr was correlated with improved RWM at rest and stress. IPPA-studies show potential to provide information about changes of perfusion and metabolism after reperfusion and IPPA-turnover is a good predictor of the pattern of contractile function

  18. Increased perfusion pressure enhances the expression of endothelin (ETB) and angiotensin II (AT1, AT2) receptors in rat mesenteric artery smooth muscle cells

    DEFF Research Database (Denmark)

    Lindstedt, Isak; Xu, Cang-Bao; Zhang, Yaping

    2009-01-01

    and luminally perfused in a perfusion chamber. After either exposure to no ("organ culture" (0 mmHg)), normal (85/75 mmHg) or high pressure (160/150 mmHg) at constant flow for 1-17 h, the vessel segments were snap frozen and real-time polymerase chain reaction was performed to quantify the ET- and AT-receptor m...

  19. Dipyridamole 201T1 myocardial perfusion tomography and bull's--eye analysis for quantitative evaluation of CAD

    International Nuclear Information System (INIS)

    Jiang Maosong; Tang Xi

    1992-01-01

    To assess the ability of quantitative analysis of dipyridamole 201 T1 tomography for detecting and localizing coronary artery disease (CAD), 55 patients with angiographically proved CAD ( = 50% stenosis) were studied. All patients underwent dipyridamole 201 T1 myocardial perfusion tomography and coronary arteriography. The overall sensitivity for detection of CAD by Bull's-eye analysis was 89% (50 patients) and 92% (51 patients) with visual analysis. The sensitivity for detecting individual vessel involvement with the Bull'-eye analysis was 88% for LAD. 81% for RCA and 67% for LCX. With visual analysis, the results were 88%, 83% and 58% respectively. The overall rate of detection was 87% in lesions greater than or equal to 75% stenosis vs 59% in those under 75% stenosis (P 201 T1 tomography using Bull's-eye display is a highly accurate reproducible technique for the detection of patients with CAD and the localization of individual coronary vessel, and it offers the potential to quantify the percentage of the abnormally perfused myocardium

  20. The value of myocardial perfusion imaging in differentiating between idiopathic dilated cardiomyopathy from the ischemic form

    International Nuclear Information System (INIS)

    Fad, A.; Emami, F.; Eftekhari, M.; Saghari, M.; Fallahi, B.; Beiki, D.; Tkavar, A.

    2004-01-01

    Introduction: differentiating between ischemic cardiomyopathy and idiopathic dilated cardiomyopathy is important as coronary revascularization can improve prognosis in the ischemic subgroup. Due to inherent problems of coronary angiography in patients with depressed ejection fraction introducing a noninvasive tool to diagnose those who will benefit from angiography seems to be rewarding. We examined usefulness of myocardial perfusion scan in this group of patients. Materials and methods: study was performed on 64 patients (62 male and 2 female) aged 57.1 ± 6.7 y (mean ± SD) all with dilation of the left ventricular cavity and ejection fraction less than 40 % by echocardiography. Myocardial perfusion scan was performed in stress and rest phases. All the patients had coronary angiography which was used as the gold standard test. On each set of images, heart was arbitrary divided into 17 segments and perfusion abnormality in each segment was scored by a 5 grade scoring system (0-4). Summed stress Score was used as the scan criteria to differentiate dilated ischemic from idiopathic cardiomyopathy. Scores more than 17 were considered ischemic, and less than that, idiopathic. Results were compared with angiography. Results: from total 40 cases of ischemic cardiomyopathy (proved by angiography) 39 were correctly diagnosed by scan and only one case was mis categorized as idiopathic dilated cardiomyopathy . All 24 cases of idiopathic dilated cardiomyopathy were correctly diagnosed by scintigraphy. Sensitivity, specificity, positive predictive value, and negative predictive value of myocardial perfusion imaging for discrimination between ischemic and idiopathic dilated cardiomyopathy were 97.5 %, 100 %, 100 %, and 96 % respectively. Conclusion: Considering excellent accuracy of myocardial perfusion scan with scoring system in discrimination of ischemic dilated cardiomyopathy from idiopathic cardiomyopathy, this noninvasive test could be considered the main diagnostic test

  1. Characteristics of images of angiographically proven normal coronary arteries acquired by adenosine-stress thallium-201 myocardial perfusion SPECT/CT-IQ[Symbol: see text]SPECT with CT attenuation correction changed stepwise.

    Science.gov (United States)

    Takahashi, Teruyuki; Tanaka, Haruki; Kozono, Nami; Tanakamaru, Yoshiki; Idei, Naomi; Ohashi, Norihiko; Ohtsubo, Hideki; Okada, Takenori; Yasunobu, Yuji; Kaseda, Shunichi

    2015-04-01

    Although several studies have shown the diagnostic and prognostic value of CT-based attenuation correction (AC) of single photon emission computed tomography (SPECT) images for diagnosing coronary artery disease (CAD), this issue remains a matter of debate. To clarify the characteristics of CT-AC SPECT images that might potentially improve diagnostic performance, we analyzed images acquired using adenosine-stress thallium-201 myocardial perfusion SPECT/CT equipped with IQ[Symbol: see text]SPECT (SPECT/CT-IQ[Symbol: see text]SPECT) from patients with angiographically proven normal coronary arteries after changing the CT attenuation correction (CT-AC) in a stepwise manner. We enrolled 72 patients (Male 36, Female 36) with normal coronary arteries according to findings of invasive coronary angiography or CT-angiography within three months after a SPECT/CT study. Projection images were reconstructed at CT-AC values of (-), 40, 60, 80 and 100 % using a CT number conversion program according to our definition and analyzed using polar maps according to sex. CT attenuation corrected segments were located from the mid- and apical-inferior spread through the mid- and apical-septal regions and finally to the basal-anterior and basal- and mid-lateral regions in males, and from the mid-inferior region through the mid-septal and mid-anterior, and mid-lateral regions in females as the CT-AC values increased. Segments with maximal mean counts shifted from the apical-anterior to mid-anterolateral region under both stress and rest conditions in males, whereas such segments shifted from the apical-septal to the mid-anteroseptal region under both stress and rest conditions in females. We clarified which part of the myocardium and to which degree CT-AC affects it in adenosine-stress thallium-201 myocardial perfusion SPECT/CT-IQ[Symbol: see text]SPECT images by changing the CT-AC value stepwise. We also identified sex-specific shifts of segments with maximal mean counts that changed as

  2. Relationship between systemic hypertension, perfusion pressure and glaucoma: A comparative study in an adult Indian population

    Directory of Open Access Journals (Sweden)

    Amit K Deb

    2014-01-01

    Full Text Available Aims: To study the relationship between blood pressure (BP, intraocular pressure (IOP, mean ocular perfusion pressure (MOPP and primary open angle glaucoma (POAG in patients with hypertension and compare it to a control group of normotensives. Design: Cross-sectional observational study. Materials and Methods: A total of 108 subjects with primary hypertension and 100 age-matched controls without hypertension were enrolled for the study. IOP measurement using Noncontact Tonometer and dilated fundus evaluation using + 90 D lens were done for all cases. Single recording of BP was taken. Gonioscopy, Humphrey′s central visual fields, optical coherence tomography and pachymetry were done for all subjects with IOP > 21 mm Hg or C: D ratio ≥ 0.5 or asymmetry of > 0.2. Statistical Analysis: Univariate and multivariate multinomial regression models were used to determine the association between covariates and risk of glaucoma or glaucoma suspect. Results: There was no difference in the glaucoma status between subjects with and without hypertension. Subjects on antihypertensive medications were 1΍ times more likely to have suspicious glaucoma (odds ratio [OR] =1.56] and nearly twice as likely to have POAG (OR = 1.85. In addition, we found a 31% and 12% reduction in risk of having POAG (95% confidence interval [CI] =13-45%, P = 0.001 and glaucoma suspect (95% CI = 2-21%, P = 0.03 respectively with every 1 mm Hg increment in MOPP. Conclusion: Subjects on antihypertensive medications are more likely to have either glaucoma or glaucoma suspect, and higher ocular perfusion pressure offers relative protection from glaucomatous damage.

  3. 13N-Ammonia pet-derived ventricular synchrony correlates with myocardial perfusion reserve better than left ventricular ejection fraction : A study in infarcted patients

    NARCIS (Netherlands)

    Juarez-Orozco, Luis Eduardo; Slart, Riemer; Tio, Rene A.; Inarra-Talboy, Fernando; Monroy, Andrea; Ayala-German, AnaGabriela; Dierckx, Rudi A.; Rosas, Erick Alexanderson

    2016-01-01

    Background: PET myocardial perfusion allows myocardial perfusion reserve (MPR) quantification as well as left ventricular ejection fraction (LVEF) and synchrony estimation through phase analysis. There is a relationship between MPR and LVEF and both have proven prognostic value in coronary artery

  4. Uridine Adenosine Tetraphosphate-Induced Coronary Relaxation Is Blunted in Swine With Pressure Overload: A Role for Vasoconstrictor Prostanoids.

    Science.gov (United States)

    Zhou, Zhichao; Lankhuizen, Inge M; van Beusekom, Heleen M; Cheng, Caroline; Duncker, Dirk J; Merkus, Daphne

    2018-01-01

    Plasma levels of the vasoactive substance uridine adenosine tetraphosphate (Up 4 A) are elevated in hypertensive patients and Up 4 A-induced vascular contraction is exacerbated in various arteries isolated from hypertensive animals, suggesting a potential role of Up 4 A in development of hypertension. We previously demonstrated that Up 4 A produced potent and partially endothelium-dependent relaxation in the porcine coronary microvasculature. Since pressure-overload is accompanied by structural abnormalities in the coronary microvasculature as well as by endothelial dysfunction, we hypothesized that pressure-overload blunts the coronary vasodilator response to Up 4 A, and that the involvement of purinergic receptors and endothelium-derived factors is altered. The effects of Up 4 A were investigated using wire-myography in isolated coronary small arteries from Sham-operated swine and swine with prolonged (8 weeks) pressure overload of the left ventricle induced by aortic banding (AoB). Expression of purinergic receptors and endothelium-derived factors was assessed in isolated coronary small arteries using real-time PCR. Up 4 A (10 -9 to 10 -5 M) failed to produce contraction in isolated coronary small arteries from either Sham or AoB swine, but produced relaxation in preconstricted arteries, which was significantly blunted in AoB compared to Sham. Blockade of purinergic P1, and P2 receptors attenuated Up 4 A-induced coronary relaxation more, while the effect of P2X 1 -blockade was similar and the effects of A 2A - and P2Y 1 -blockade were reduced in AoB as compared to Sham. mRNA expression of neither A1, A2, A3, nor P2X 1 , P2X 7 , P2Y 1 , P2Y 2 , nor P2Y 6 -receptors was altered in AoB as compared to Sham, while P2Y 12 expression was higher in AoB. eNOS inhibition attenuated Up 4 A-induced coronary relaxation in both Sham and AoB. Additional blockade of cyclooxygenase enhanced Up 4 A-induced coronary relaxation in AoB but not Sham swine, suggesting the involvement

  5. Pulmonary O2 transfer during pulsatile and non-pulsatile perfusion.

    Science.gov (United States)

    Hauge, A; Nicolaysen, G

    1980-07-01

    The importance of the perfusion pattern for the oxygen transfer has been examined in isolated rabbit lungs perfused with plasma at constant volume inflow. The lungs were ventilated with constant tidal volume and constant end-expiratory pressure. Following a standardized rise in FIO2 the rate of rise in pulmonary venous PO2 (delta PO2/delta t) was measured during alternately pulsatile and non-pulsatile perfusion in normal lungs and in lungs made edematous by elevation of left atrial pressure. In normal lungs there was no difference in delta PO2/delta t when the two modes of perfusion were compared. In edematous lungs delta PO/delta t was statistically higher during pulsatile perfusion, indicating a beneficial effect of flow- and pressure pulsations, e.g. a better distribution of V/Q ratios throughout the lungs. In a separate series of expts. the advancement of a high O2 front through the airways was measured, and the two perfusion patterns compared. Since no difference was found, we suggest that the phenomenon of "cardiogenic gas mixing" in the airways in vivo is a result of a direct action of the heart on the lungs rather than arterial pulsations.

  6. Perfusion single photon emission computed tomography of myocardium with 99mTc-tetra-phosmine (Myoview)

    International Nuclear Information System (INIS)

    Khusainova, Sh.K.; Zholdybaj, Zh.; Potapov, A.V.; Karaev, O.S.; Akhmetova, G.R.

    2003-01-01

    The aim of the work is study of diagnostic valuation of myocardium scintigraphy with help of the 99m Tc-tetrophosmin, Myoview in determination of latent coronary blood-circulation destabilization in liquidators of the Chernobyl accident (LChA) and persons living in the Semipalatinsk test site (STS) region. The perfusion myocardium scintigraphy was made to 71 patients (5 women and 66 men) from those - 33 LChA and 37 - residents of STS region. The examination was carried out in 'ADAC Genesys Epic' apparatus (USA). Mean age of the patients was 46.3±2.3 years old. In the result of examination the left ventricle myocardium perfusion reduction on 30 % and more was revealed. The distribution of radiopharmaceutical by the myocardium parts were relatively proportional both with pharmacologic load (ATF, dipiridamol) and the rest in 48 (67.7 %) patients. So, the 99m Tc-tetrophosmin, Myoview pharmaceutical allows with high rate estimate the myocardium perfusion and get a high qualitative images, that permits to identify localization, character and distribution of myocardium perfusion reduction in the revealed areas. In the result of myocardine scintigraphy with the pharmacologic load trial conducting the both the latent coronary blood-circulation destabilization forms and the incoming ones were differentiated

  7. Normal myocardial perfusion scan portends a benign prognosis independent from the pretest probability of coronary artery disease. Sub-analysis of the J-ACCESS study

    International Nuclear Information System (INIS)

    Imamura, Yosihiro; Fukuyama, Takaya; Nishimura, Sigeyuki; Nishimura, Tsunehiko

    2009-01-01

    We assessed the usefulness of gated stress/rest 99mTc-tetrofosmin myocardial perfusion single photon emission computed tomography (SPECT) to predict ischemic cardiac events in Japanese patients with various estimated pretest probabilities of coronary artery disease (CAD). Of the 4031 consecutively registered patients for a J-ACCESS (Japanese Assessment of Cardiac Events and Survival Study by Quantitative Gated SPECT) study, 1904 patients without prior cardiac events were selected. Gated stress/rest myocardial perfusion SPECT was performed and segmental perfusion scores and quantitative gated SPECT results were derived. The pretest probability for having CAD was estimated using the American College of Cardiology/American Heart Association/American College of Physicians- American Society of Internal Medicine guideline data for the management of patients with chronic stable angina, which includes age, gender, and type of chest discomfort. The patients were followed up for three years. During the three-year follow-up period, 96 developed ischemic cardiac events: 17 cardiac deaths, 8 nonfatal myocardial infarction, and 71 clinically driven revascularization. The summed stress score (SSS) was the most powerful independent predictor of all ischemic cardiac events (hazard ratio 1.077, confidence interval (CI) 1.045-1.110). Abnormal SSS (>3) was associated with a significantly higher cardiac event rate in patients with an intermediate to high pretest probability of CAD. Normal SSS (≤3) was associated with a low event rate in patients with any pretest probability of CAD. Myocardial perfusion SPECT is useful for further risk-stratification of patients with suspected CAD. The abnormal scan result (SSS>3) is discriminative for subsequent cardiac events only in the groups with an intermediate to high pretest probability of CAD. The salient result is that normal scan results portend a benign prognosis independent from the pretest probability of CAD. (author)

  8. Relationship between pre-extubation positive endexpiratory pressure and oxygenation after coronary artery bypass grafting

    Directory of Open Access Journals (Sweden)

    Reijane Oliveira Lima

    2015-08-01

    Full Text Available Abstract Introduction After removal of endotracheal tube and artificial ventilation, ventilatory support should be continued, offering oxygen supply to ensure an arterial oxygen saturation close to physiological. Objective: The aim of this study was to investigate the effects of positive-end expiratory pressure before extubation on the oxygenation indices of patients undergoing coronary artery bypass grafting. Methods: A randomized clinical trial with seventy-eight patients undergoing coronary artery bypass grafting divided into three groups and ventilated with different positive-end expiratory pressure levels prior to extubation: Group A, 5 cmH2O (n=32; Group B, 8 cmH2O (n=26; and Group C, 10 cmH2O (n=20. Oxygenation index data were obtained from arterial blood gas samples collected at 1, 3, and 6 h after extubation. Patients with chronic pulmonary disease and those who underwent off-pump, emergency, or combined surgeries were excluded. For statistical analysis, we used Shapiro-Wilk, G, Kruskal-Wallis, and analysis of variance tests and set the level of significance at P<0.05. Results Groups were homogenous with regard to demographic, clinical, and surgical variables. There were no statistically significant differences between groups in the first 6 h after extubation with regard to oxygenation indices and oxygen therapy utilization. Conclusion: In this sample of patients undergoing coronary artery bypass grafting, the use of different positive-end expiratory pressure levels before extubation did not affect gas exchange or oxygen therapy utilization in the first 6 h after endotracheal tube removal.

  9. Perfusion Pressure Cerebral Infarct (PPCI) trial - the importance of mean arterial pressure during cardiopulmonary bypass to prevent cerebral complications after cardiac surgery

    DEFF Research Database (Denmark)

    Vedel, Anne G.; Holmgaard, Frederik; Rasmussen, Lars Simon

    2016-01-01

    Background: Debilitating brain injury occurs in 1.6–5 % of patients undergoing cardiac surgery with cardiopulmonary bypass. Diffusion-weighted magnetic resonance imaging studies have reported stroke-like lesions in up to 51 % of patients after cardiac surgery. The majority of the lesions seem...... to be caused by emboli, but inadequate blood flow caused by other mechanisms may increase ischaemia in the penumbra or cause watershed infarcts. During cardiopulmonary bypass, blood pressure can be below the lower limit of cerebral autoregulation. Although much debated, the constant blood flow provided...... by the cardiopulmonary bypass system is still considered by many as appropriate to avoid cerebral ischaemia despite the low blood pressure. Methods/design: The Perfusion Pressure Cerebral Infarct trial is a single-centre superiority trial with a blinded outcome assessment. The trial is randomising 210 patients...

  10. Clinical perspective of coronary computed tomographic angiography in diagnosis of coronary artery disease

    International Nuclear Information System (INIS)

    Chang, Hyuk-Jae; Chung, Namsik

    2011-01-01

    Since a 4-detector row coronary computed tomographic angiography (CCTA) was launched in 1998, CCTA has experienced rapid improvement of imaging qualities with the ongoing evolution of computed tomography (CT) technology. The diagnostic accuracy of CCTA to detect coronary artery stenosis is well established, whereas improvements are still needed to reduce the overestimation of coronary artery disease (CAD) and assess plaque composition. CCTA has been used to evaluate CAD in various clinical settings. For example, CCTA could be an efficient initial triage tool at emergency departments for patients with acute chest pain with low-to-intermediate risk because of its high negative predictive value. In patients with suspected CAD, CCTA could be a cost-effective alternative to myocardial perfusion imaging and exercise electrocardiogram for the initial coronary evaluation of patients with intermediate pre-test likelihood suspected CAD. However, in asymptomatic populations, there is a lack of studies that show an improved prognostic power of CCTA over other modalities. Therefore, the clinical use of CCTA to detect CAD for purposes of risk stratification in asymptomatic individuals should be discouraged. As CT technology evolves, CCTA will provide better quality coronary imaging and non-coronary information with lower radiation exposure. Future studies should cover these ongoing technical improvements and evaluate the prognostic power of CCTA in various clinical settings of CAD in large, well-designed, randomized trials. (author)

  11. The prognostic value of 99MTc-MIBI stress-rest myocardial perfusion imaging in patients suspected with coronary artery disease

    International Nuclear Information System (INIS)

    Wu Zhifang; Li Sijin; Liu Jianzhong; Zhang Wanchun

    2004-01-01

    Objective: To evaluate the prognostic value of 99mTc-MIBI stress-rest myocardial perfusion imaging (MPI) for patients suspected with coronary artery disease (CAD). Methods: 206 consecutive patients suspected with CAD (165 males, 41 females; age range 16-90 years, mean age 55.94±12.46 years) underwent 99mTc-MIBI stress-rest myocardial perfusion imaging (two days protocol), 57 pts with hypertension, 68 pts with hyperlipemia, 39 pts with diabetes and 62 pts with the family history of CAD. According to the imaging results, the 206 patients were divided into 3 groups. G1, normal, 135 pts; G2, reversible defects, 20 pts; G3, fixed defects, 51 pts. The mean time of follow-up was 33.25±14.95 (1-56) months. Results: The rate of cardiac events (CE) occurrence of the three groups was 1.5% (2/135), 65% ( 13/20) and 7.8% (4/51) respectively and there was significant difference between them. Kaplan-Meier survival curves analyzing the no-CE rates in the three groups, ischemic patients demonstrated a more significantly lower than normal and infarction ones in the no-CE rates(Log-rank statistic, chi-square 124.89, P <0.0001). The better predictor of future cardiac events is the reversible defect. Over all, 23.9% of the patients with abnormal stress MPI occurred cardiac events, but only 7.5% of the patients with abnormal rest ones did(chi-square 5.80, P =0.016). The prognoses of patients with normal stress MPI result were better than those with normal rest ones (1.5% versus 9.7%, chi-square 8.94, P =0.0028). Compared with rest MPI, the stress one is a better predictable method to analyze the patient' s condition and evaluate the prognosis. Conclusions: 99mTc-MIBI stress-rest myocardial perfusion imaging is a better Methods to evaluate the prognosis of patients suspected with CAD, and the rate of CE occurrence was 65% in reversible defects patients in this study. (authors)

  12. Noninvasive assessment of changes in myocardial perfusion and ventricular performance following exercise training

    International Nuclear Information System (INIS)

    Tubau, J.; Witztum, K.; Froelicher, V.; Jensen, D.; Atwood, E.; McKirnan, M.D.; Reynolds, J.; Ashburn, W.

    1982-01-01

    Seventeen coronary patients (CAD) underwent 201 Tl treadmill and radionuclide (RNV) ejection fraction supine bicycle testing before and after 5.6 +/- 1.6 (mean +/- SD) months of an exercise program. Thallium data were assessed both using analog images and a computerized circumferential profile technique. Patients exercised on the treadmill to a higher workload after the exercise program, but achieved a similar pressure-rate product. When interpreting the analog thallium images, only 50% agreement was obtained for the assessment of changes in myocardial perfusion (pre/post-training). The computer technique, however, had low inter-intraobserver variability (6%) and better agreement (90.5%). Using the circumferential profile method, five patients improved (a total of 11 regions) and one patient worsened (with two regions). Before the exercise program, the ejection fraction (EF) response to supine bike exercise was normal (an increase greater than 11%) in four, flat in seven, and severely abnormal (a decrease of more than 4%) in six patients. After the exercise program, even though achieving similar or higher pressure-rate products, six patients improved their EF response, nine did not change, and two worsened. Of the five patients who improved their thallium images, one improved his EF response, two remained normal, and two did not change. One patient worsened both his thallium study and the EF response after the exercise program. Changes in thallium exercise images and the EF response to supine exercise occurred in our patients after an exercise program, but were not always concordant. Indeed, of five patients with exercise-induced ischemic ST changes before and after training, the EF response improved in three whereas myocardial perfusion was unchanged. Reasons for this lack of agreement are discussed, and have been considered in the planning of a randomized trial of the effects of an exercise program on myocardial perfusion and function

  13. Impaired exercise-related myocardial uptake of technetium-99m-tetrofosmin in relation to coronary narrowing and diabetic state

    International Nuclear Information System (INIS)

    Sasao, Hisataka; Nakata, Tomoaki; Tsuchihashi, Kazufumi; Wakabayashi, Takeru; Nakahara, Norifumi; Doi, Atsushi; Hashimoto, Akiyoshi; Kobayashi, Hiroshi; Shimamoto, Kazuaki

    2001-01-01

    Despite the diagnostic efficacy of stress myocardial perfusion imaging, the correlation between the actual perfusion tracer activity and diseased state of a coronary artery has not been studied in detail. We estimated exercise-related perfusion augmentation in relation to disease states of a coronary artery in diabetic and non-diabetic patients by a newly developed quantitative technetium (Tc)-99m-tetrofosmin myocardial imaging technique. Tc-99m-tetrofosmin tomographic imaging with an exercise-rest protocol was performed in 26 stable coronary patients and in 8 age-matched controls. Percent increase (%IR) in myocardial count during symptom-limited submaximal exercise-stress was calculated in 16 non-infarcted polar map segments and in each coronary territory by a subtraction technique with corrections for physical decay and injected tracer doses, and the results were compared with those of angiographically quantified coronary diameter stenosis (%DS). Percent IR and peak heart rate during exercise showed a positive linear correlation both in coronary territories with significant stenosis (%DS≥75%) and in control or non-stenotic (%DS<75%) territories. The regression line in stenotic regions was, however, significantly (p<0.01) shifted downward compared to that in non-stenotic regions. Percent IR in stenotic regions showed a significant inverse correlation with %DS. Coronary stenosis of 75% or more was identified by a %IR cutoff value of 40% with 77% sensitivity, 70% specificity, and an accuracy of 72%. In coronary territories with a %DS of less than 75%, %IR in diabetic patients was significantly lower (46±15%) than that in non-diabetic patients (61±25%). Thus, blunted exercise-related augmentation of myocardial uptake of Tc-99m-tetrofosmin correlates with the severity of coronary narrowing and diabetic state. (author)

  14. Clinical value, cost-effectiveness, and safety of myocardial perfusion scintigraphy: a position statement

    DEFF Research Database (Denmark)

    Marcassa, C.; Bax, J.J.; Bengel, F.

    2008-01-01

    Mortality rates due to coronary artery disease (CAD) have declined in recent years as result of improved prevention, diagnosis, and management. Nonetheless, CAD remains the leading cause of death worldwide with most casualties expected to occur in developing nations. Myocardial perfusion scintigr...

  15. Tolerance and safety of pharmacologic coronary vasodilation with adenosine in association with thallium-201 scintigraphy in patients with suspected coronary artery disease

    International Nuclear Information System (INIS)

    Abreu, A.; Mahmarian, J.J.; Nishimura, S.; Boyce, T.M.; Verani, M.S.

    1991-01-01

    Adenosine thallium-201 myocardial scintigraphy is a promising test for coronary artery disease detection, but its safety has not been reported in large patient cohorts. Accordingly, the tolerance and safety profile of adenosine infusion were analyzed in 607 patients (351 men, 256 women, mean age 63 ± 11 years) undergoing this test either because of suspected coronary artery disease (Group I, n = 482) or for risk stratification early (5.2 ± 2.8 days) after myocardial infarction (Group II, n = 125). Adenosine increased the heart rate from 74.5 ± 14.0 to 91.8 ± 15.9 beats/min (p less than 0.001) and decreased systolic blood pressure from 137.8 ± 26.8 to 120.7 ± 26.1 mm Hg (p less than 0.001). Side effects were frequent and similar in both groups. Flushing occurred in 35%, chest pain in 34%, headache in 21% and dyspnea in 19% of patients. Only 35.6% of Group I patients with chest pain during adenosine infusion had concomitant transient perfusion abnormalities, compared with 60.7% of Group II patients (p less than 0.05). First- and second-degree AV block occurred in 9.6% and 3.6% of patients, respectively, and ischemic ST changes in 12.5% of cases. Concomitance of chest pain and ischemic ST depression was uncommon (6%) but, when present, predicted perfusion abnormalities in 73% of patients. Most side effects ceased rapidly after stopping the adenosine infusion. The side effects were severe in only 1.6% of patients and in only six patients (1%) was it necessary to discontinue the infusion. No serious adverse reactions such as acute myocardial infarction or death occurred

  16. General concepts of ventricular function, Myocardial perfusion, and exercise physiology relevant to nuclear cardiology

    International Nuclear Information System (INIS)

    Kronenberg, M.W.; Becker, L.C.

    1988-01-01

    Knowledge of ventricular mechanics, the physiology of the coronary circulation, and exercise physiology is necessary for the accurate interpretation of radionuclide ventriculographic and myocardial perfusion images. This chapter outlines these important basic concepts as applied to the whole heart

  17. Quantitative perfusion parameters in a cohort of patients with no known ischemic heart disease and normal myocardial perfusion imaging studied by 82Rb-PET

    DEFF Research Database (Denmark)

    Hoff, Camilla; Balche, Abdallah; Majgaard, J

    Purpose 82Rb perfusion PET allows for visual as well as quantitative interpretation of myocardial function. Whereas visual interpretation relies on intra-individual redistribution of the tracer between rest and stress studies, quantitative interpretation of absolute flow values requires robust.......86 mL/g/min. Global coronary flow reserve (CFR) was 2.81 (±SD 0.71). EF at rest was 65.3% (±SD 10) and during stress 69% (±SD 12.3), yielding an EF reserve of 4.5%. TPD at rest and stress was 6% (±SD 4). Conclusion Based on a representative population of patients in which coronary artery disease...

  18. Corpuls CPR Generates Higher Mean Arterial Pressure Than LUCAS II in a Pig Model of Cardiac Arrest

    Directory of Open Access Journals (Sweden)

    S. Eichhorn

    2017-01-01

    Full Text Available According to the European Resuscitation Council guidelines, the use of mechanical chest compression devices is a reasonable alternative in situations where manual chest compression is impractical or compromises provider safety. The aim of this study is to compare the performance of a recently developed chest compression device (Corpuls CPR with an established system (LUCAS II in a pig model. Methods. Pigs (n = 5/group in provoked ventricular fibrillation were left untreated for 5 minutes, after which 15 min of cardiopulmonary resuscitation was performed with chest compressions. After 15 min, defibrillation was performed every 2 min if necessary, and up to 3 doses of adrenaline were given. If there was no return of spontaneous circulation after 25 min, the experiment was terminated. Coronary perfusion pressure, carotid blood flow, end-expiratory CO2, regional oxygen saturation by near infrared spectroscopy, blood gas, and local organ perfusion with fluorescent labelled microspheres were measured at baseline and during resuscitation. Results. Animals treated with Corpuls CPR had significantly higher mean arterial pressures during resuscitation, along with a detectable trend of greater carotid blood flow and organ perfusion. Conclusion. Chest compressions with the Corpuls CPR device generated significantly higher mean arterial pressures than compressions performed with the LUCAS II device.

  19. Continuous Perfusion of Saphenous Vein by Oxygenated Blood during Beating Coronary Surgery

    Directory of Open Access Journals (Sweden)

    Mohammad Hossein Mandegar

    2015-09-01

    Full Text Available Background: The saphenous vein remains the most commonly used conduit for coronary artery bypass surgery (CABG. However, the long-term success of surgical revascularization is largely limited by development of occlusion in vein grafts. Objectives: We sought to reduce graft ischemia by maintaining the blood flow into the harvested vein throughout surgery at lowest costs and without special devices. Patients and Methods: This study was conducted on three hundred patients aged 58.5 ± 8 years undergoing elective first-time off-pump CABG with saphenous veins. Results: In addition to preserving nutritional materials and oxygen, the veins harvested via this novel technique did not go into spasm and were not subjected to high-pressure distension, eventually resulting in minimal damage to the endothelium. Conclusions: This technique confers favorable myocardial function and protection in the presence of left ventricular dysfunction, especially in elderly patients.

  20. Relation of coronary vasoreactivity and coronary calcification in asymptomatic subjects with a family history of premature coronary artery disease

    International Nuclear Information System (INIS)

    Pirich, Christian; Leber, Alexander; Knez, Andreas; Bengel, Frank M.; Nekolla, Stephan G.; Schwaiger, Markus; Haberl, Ralph

    2004-01-01

    Electron-beam computed tomography (EBCT) allows non-invasive imaging of coronary calcification and has been promoted as a screening tool for coronary artery disease (CAD) in asymptomatic high-risk subjects. This study assessed the relation of coronary calcifications to alterations in coronary vascular reactivity by means of positron emission tomography (PET) in asymptomatic subjects with a familial history of premature CAD. Twenty-one subjects (mean age 51±10 years) underwent EBCT imaging for coronary calcifications expressed as the coronary calcium score (CCS according to Agatston) and rest/adenosine-stress nitrogen-13 ammonia PET with quantification of myocardial blood flow (MBF) and coronary flow reserve (CFR). The mean CCS was 237±256 (median 146, range 0-915). The CCS was 100 units in 13. As defined by age-related thresholds, 15 subjects had an increased CCS (>75th percentile). Overall mean resting and stress MBF and CFR were 71±16 ml 100 g -1 min -1 , 218±54 ml 100 g -1 min -1 and 3.20±0.77, respectively. Three subjects with CCS ranging from 114 to 451 units had an abnormal CFR (<2.5). There was no relation between CCS and resting or stress MBF or CFR (r=0.17, 0.18 and 0.10, respectively). In asymptomatic subjects a pathological CCS was five times more prevalent than an abnormal CFR. The absence of any close relationship between CCS and CFR reflects the fact that quantitative myocardial perfusion imaging with PET characterises the dynamic process of vascular reactivity while EBCT is a measure of more stable calcified lesions in the arterial wall whose presence is closely related to age. (orig.)

  1. Prognostic utility of carotid ultrasound and cardiac SPECT imaging in coronary artery bypass patients

    International Nuclear Information System (INIS)

    Bosevski, M.; Peovska, I.; Maksimovic, J.; Vavlukis, M.; Meskovska, S.

    2006-01-01

    The aim of our study was to evaluate the role of myocardial perfusion imaging (MPI) and common carotid artery intima-media thickness (CCA IMT) in the prognosis of patients with coronary artery disease referred for coronary artery bypass surgery (CABG) in a newly made prognostic model. 63 patients (age 60.36 ± 8.28 years) with angiographically established coronary artery disease referred for CABG were evaluated for: age, smoking, family disposition, dyslipidaemia, arterial hypertension, obesity, diabetes mellitus, previous myocardial infarction and revascularization. Patients underwent nitrate enhanced Gated SPECT myocardial perfusion imaging, with 17-segment analysis for calculation of perfusion scores and viability index. Common carotid artery IMT was measured by B-mode ultrasound. Patients were followed for cardiovascular events 12 months after CABG. The obtained data reported mean values of left ventricular ejection fraction (LVEF) 46.2±14.4%, viability index 0.76± 0.55, SRS 17.76±13.81 and summed nitrate score 12.89 ±10.36. Ultrasound detected CCA IMT 0.90± 0.24 mm, with increased value in 67.2% and presence of carotid plaques in 27.1% of pts. We registered 14 events and 8.8% mortality rate. Multiple regression modelling showed bilateral carotid plaque presence as a predictor of total events. Viability index and CCA IMT have been found as independent death predictors. Myocardial perfusion viability index and CCA IMT are predictors, independently associated with prognosis of patients referred for CABG. (author)

  2. Integrated SPECT/CT for assessment of haemodynamically significant coronary artery lesions in patients with acute coronary syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Rispler, Shmuel [Technion - Israel Institute of Technology, Department of Cardiology, Rambam Health Care Campus and the B. Rappaport Faculty of Medicine, Haifa (Israel); Technion - Israel Institute of Technology, Department of Nuclear Medicine, Rambam Health Care Campus and the B. Rappaport Faculty of Medicine, Haifa (Israel); Aronson, Doron; Roguin, Ariel; Beyar, Rafael [Technion - Israel Institute of Technology, Department of Cardiology, Rambam Health Care Campus and the B. Rappaport Faculty of Medicine, Haifa (Israel); Abadi, Sobhi; Engel, Ahuva [Technion - Israel Institute of Technology, Department of Medical Imaging, Rambam Health Care Campus and the B. Rappaport Faculty of Medicine, Haifa (Israel); Israel, Ora; Keidar, Zohar [Technion - Israel Institute of Technology, Department of Nuclear Medicine, Rambam Health Care Campus and the B. Rappaport Faculty of Medicine, Haifa (Israel)

    2011-10-15

    Early risk stratification in patients with non-ST elevation acute coronary syndromes (NSTE-ACS) is important since the benefit from more aggressive and costly treatment strategies is proportional to the risk of adverse clinical events. In the present study we assessed whether hybrid single photon emission computed tomography (SPECT)/coronary computed tomography angiography (CCTA) technology could be an appropriate tool in stratifying patients with NSTE-ACS. SPECT/CCTA was performed in 90 consecutive patients with NSTE-ACS. The Thrombolysis in Myocardial Infarction risk score (TIMI-RS) was used to classify patients as low- or high-risk. Imaging was performed using SPECT/CCTA to identify haemodynamically significant lesions defined as >50% stenosis on CCTA with a reversible perfusion defect on SPECT in the corresponding territory. CCTA demonstrated at least one lesion with >50% stenosis in 35 of 40 high-risk patients (87%) as compared to 14 of 50 low-risk patients (35%; TIMI-RS <3; p <0.0001). Of the 40 high-risk and 50 (16%) low-risk TIMI-RS patients, 16 (40%) and 8 (16%), respectively, had haemodynamically significant lesions (p = 0.01). Patients defined as high-risk by a high TIMI-RS, a positive CCTA scan or both (n = 45) resulted in a sensitivity of 95%, specificity of 49%, PPV of 35% and NPV of 97% for having haemodynamically significant coronary lesions. Those with normal perfusion were spared revascularization procedures, regardless of their TIMI-RS. Noninvasive assessment of coronary artery disease by SPECT/CCTA may play an important role in risk stratification of patients with NSTE-ACS by better identifying the subgroup requiring intervention. (orig.)

  3. Integrated SPECT/CT for assessment of haemodynamically significant coronary artery lesions in patients with acute coronary syndrome

    International Nuclear Information System (INIS)

    Rispler, Shmuel; Aronson, Doron; Roguin, Ariel; Beyar, Rafael; Abadi, Sobhi; Engel, Ahuva; Israel, Ora; Keidar, Zohar

    2011-01-01

    Early risk stratification in patients with non-ST elevation acute coronary syndromes (NSTE-ACS) is important since the benefit from more aggressive and costly treatment strategies is proportional to the risk of adverse clinical events. In the present study we assessed whether hybrid single photon emission computed tomography (SPECT)/coronary computed tomography angiography (CCTA) technology could be an appropriate tool in stratifying patients with NSTE-ACS. SPECT/CCTA was performed in 90 consecutive patients with NSTE-ACS. The Thrombolysis in Myocardial Infarction risk score (TIMI-RS) was used to classify patients as low- or high-risk. Imaging was performed using SPECT/CCTA to identify haemodynamically significant lesions defined as >50% stenosis on CCTA with a reversible perfusion defect on SPECT in the corresponding territory. CCTA demonstrated at least one lesion with >50% stenosis in 35 of 40 high-risk patients (87%) as compared to 14 of 50 low-risk patients (35%; TIMI-RS <3; p <0.0001). Of the 40 high-risk and 50 (16%) low-risk TIMI-RS patients, 16 (40%) and 8 (16%), respectively, had haemodynamically significant lesions (p = 0.01). Patients defined as high-risk by a high TIMI-RS, a positive CCTA scan or both (n = 45) resulted in a sensitivity of 95%, specificity of 49%, PPV of 35% and NPV of 97% for having haemodynamically significant coronary lesions. Those with normal perfusion were spared revascularization procedures, regardless of their TIMI-RS. Noninvasive assessment of coronary artery disease by SPECT/CCTA may play an important role in risk stratification of patients with NSTE-ACS by better identifying the subgroup requiring intervention. (orig.)

  4. Discrepancy between microsphere and diffusible tracer estimates of perfusion to ischemic myocardium

    International Nuclear Information System (INIS)

    Yoshida, S.; Akizuki, S.; Gowski, D.; Downey, J.M.

    1985-01-01

    This study critically tests the ability of microspheres to accurately measure perfusion to ischemic myocardium. The left anterior descending coronary artery was cannulated and perfused with arterial blood. The perfusion line was clamped, and a sidearm between the clamp and the cannula was opened to the atmosphere, allowing blood to flow retrograde from the distal segment of the artery. Measurement of regional blood flow during retrograde flow diversion with 15-micron microspheres revealed essentially zero flow to the perfused segment (0.005 ml X min-1 X g-1). Measurements under the same conditions by either 86 Rb uptake or 133 Xe washout revealed that an appreciable perfusion of the tissue persisted during retrograde flow diversion (0.043 and 0.11 ml X min-1 X g-1, respectively, for the 2 methods). Thus, the authors have identified a condition during which microspheres indicate zero flow to the tissue but diffusible tracers can both be washed in and washed out at a brisk rate. They conclude that with simple occlusion there is a hidden component of perfusion to an ischemic zone that cannot be measured by microspheres, causing them to underestimate flow by about 25% in that condition

  5. Correlation between cerebral hemodynamic and perfusion pressure changes in non-human primates

    Science.gov (United States)

    Ruesch, A.; Smith, M. A.; Wollstein, G.; Sigal, I. A.; Nelson, S.; Kainerstorfer, J. M.

    2017-02-01

    The mechanism that maintains a stable blood flow in the brain despite changes in cerebral perfusion pressure (CPP), and therefore guaranties a constant supply of oxygen and nutrients to the neurons, is known as cerebral auto-regulation (CA). In a certain range of CPP, blood flow is mediated by a vasomotor adjustment in vascular resistance through dilation of blood vessels. CA is known to be impaired in diseases like traumatic brain injury, Parkinson's disease, stroke, hydrocephalus and others. If CA is impaired, blood flow and pressure changes are coupled and thee oxygen supply might be unstable. Lassen's blood flow auto-regulation curve describes this mechanism, where a plateau of stable blood flow in a specific range of CPP corresponds to intact auto-regulation. Knowing the limits of this plateau and maintaining CPP within these limits can improve patient outcome. Since CPP is influenced by both intracranial pressure and arterial blood pressure, long term changes in either can lead to auto-regulation impairment. Non-invasive methods for monitoring blood flow auto-regulation are therefore needed. We propose too use Near infrared spectroscopy (NIRS) too fill this need. NIRS is an optical technique, which measures microvascular changes in cerebral hemoglobin concentration. We performed experiments on non-human primates during exsanguination to demonstrate that thee limits of blood flow auto-regulation can be accessed with NIRS.

  6. Quantitative relationship between coronary calcium content and coronary flow reserve as assessed by integrated PET/CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Curillova, Zelmira [Brigham and Women' s Hospital, Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Boston, MA (United States); VA Boston Healthcare System, Division of Cardiology, Department of Medicine, West Roxbury, MA (United States); Yaman, Bettina F.; Sitek, Arkadius; El Fakhri, Georges [Brigham and Women' s Hospital, Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Boston, MA (United States); Dorbala, Sharmila [Brigham and Women' s Hospital, Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Boston, MA (United States); Brigham and Women' s Hospital, Noninvasive Cardiovascular Imaging Program, Departments of Medicine (Cardiology) and Radiology, Boston, MA (United States); Kwong, Raymond Y. [Harvard Medical School, Division of Cardiovascular Medicine, Department of Medicine, Brigham and Women' s Hospital, Boston, MA (United States); Brigham and Women' s Hospital, Noninvasive Cardiovascular Imaging Program, Departments of Medicine (Cardiology) and Radiology, Boston, MA (United States); Anagnostopoulos, Constantinos [Brigham and Women' s Hospital, Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Boston, MA (United States); Royal Brompton Hospital, Department of Nuclear Medicine, London (United Kingdom); Di Carli, Marcelo F. [Brigham and Women' s Hospital, Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Boston, MA (United States); Harvard Medical School, Division of Cardiovascular Medicine, Department of Medicine, Brigham and Women' s Hospital, Boston, MA (United States); Brigham and Women' s Hospital, Noninvasive Cardiovascular Imaging Program, Departments of Medicine (Cardiology) and Radiology, Boston, MA (United States); Brigham and Women' s Hospital, Division of Nuclear Medicine and Molecular Imaging, Boston, MA (United States)

    2009-10-15

    To evaluate the relationship between coronary artery calcium (CAC) and coronary vasodilator function. We evaluated 136 patients without known coronary artery disease (CAD) undergoing vasodilator stress {sup 82}Rb PET/CT and CAC scoring who showed normal myocardial perfusion. The CAC score, resting and hyperemic myocardial blood flow (MBF), coronary flow reserve (CFR) and coronary vascular resistance were analyzed. Global and regional CAC scores showed significant but weak inverse correlations with hyperemic MBF (r=-0.31 and r=-0.26, p{<=}0.0002 respectively) and CFR (r=-0.28 and r=-0.2, p{<=}0.001 respectively). With increasing CAC score, there was a modest stepwise decline in CFR on a per-patient basis (1.8{+-}0.5 vs 1.7{+-}0.5 vs 1.5{+-}0.4, p=0.048, with total CAC=0, 1-400 and >400, respectively) and on a per-vessel basis. In multivariable modeling only body mass index and CAC score were predictive of CFR. In patients with an intermediate likelihood of, but without overt, CAD, there is a statistically significant but weak inverse correlation between CAC content and coronary vasodilator function. The strength of this association weakens after adjusting CAC scores for age, gender and coronary risk factors. This suggests that CAC and coronary vasodilator function provide biologically different information regarding atherosclerosis. (orig.)

  7. Quantitative relationship between coronary calcium content and coronary flow reserve as assessed by integrated PET/CT imaging

    International Nuclear Information System (INIS)

    Curillova, Zelmira; Yaman, Bettina F.; Sitek, Arkadius; El Fakhri, Georges; Dorbala, Sharmila; Kwong, Raymond Y.; Anagnostopoulos, Constantinos; Di Carli, Marcelo F.

    2009-01-01

    To evaluate the relationship between coronary artery calcium (CAC) and coronary vasodilator function. We evaluated 136 patients without known coronary artery disease (CAD) undergoing vasodilator stress 82 Rb PET/CT and CAC scoring who showed normal myocardial perfusion. The CAC score, resting and hyperemic myocardial blood flow (MBF), coronary flow reserve (CFR) and coronary vascular resistance were analyzed. Global and regional CAC scores showed significant but weak inverse correlations with hyperemic MBF (r=-0.31 and r=-0.26, p≤0.0002 respectively) and CFR (r=-0.28 and r=-0.2, p≤0.001 respectively). With increasing CAC score, there was a modest stepwise decline in CFR on a per-patient basis (1.8±0.5 vs 1.7±0.5 vs 1.5±0.4, p=0.048, with total CAC=0, 1-400 and >400, respectively) and on a per-vessel basis. In multivariable modeling only body mass index and CAC score were predictive of CFR. In patients with an intermediate likelihood of, but without overt, CAD, there is a statistically significant but weak inverse correlation between CAC content and coronary vasodilator function. The strength of this association weakens after adjusting CAC scores for age, gender and coronary risk factors. This suggests that CAC and coronary vasodilator function provide biologically different information regarding atherosclerosis. (orig.)

  8. Intact nitric oxide production is obligatory for the sustained flow response during hypercapnic acidosis in guinea pig heart.

    Science.gov (United States)

    Heintz, Anke; Koch, Thea; Deussen, Andreas

    2005-04-01

    The mechanisms underlying hypercapnic coronary dilation remain unsettled. This study tests the hypothesis that flow dependent NO production is obligatory for the hypercapnic flow response. In isolated, constant pressure (CP) perfused guinea pig hearts a step change of arterial pCO(2) from 38.6 to 61.4 mm Hg induced a bi-phasic flow response with an early transient (maximum 60 s) and a consecutive persisting flow rise (121.6+/-6.6 (S.D.) % after 10 min). In contrast, when perfused with constant flow (CF), perfusion pressure only transiently (2 min) fell by 7.4+/-4.8 % following the step change of arterial pCO(2). In CP perfused hearts L-NAME (100 micromol/l) specifically abolished the delayed flow rise during hypercapnic acidosis (102.37+/-2.9% after 10 min), whereas the inhibitor had no effect on perfusion pressure response in CF perfused hearts. Under CP perfusion arterial hypercapnia resulted in a transient rise of coronary cGMP release (from 0.69+/-0.35 to 1.12+/-0.68 pmol/ml), which was abolished after L-NAME. Surprisingly, the K(+)ATP channel blocker glibenclamide did not have any significant effect on the hypercapnic flow response but largely blunted reactive hyperemia after a 20 s flow stop. The delayed steady state hypercapnic flow response in guinea pig heart requires intact NO production. The absence of a persisting decrease in coronary resistance under CF perfusion points to an important role of shear stress dependent NO production.

  9. Development of Coronary Pulse Wave Velocity: New Pathophysiological Insight Into Coronary Artery Disease.

    Science.gov (United States)

    Harbaoui, Brahim; Courand, Pierre-Yves; Cividjian, Andrei; Lantelme, Pierre

    2017-02-02

    Although aortic stiffness assessed by pulse wave velocity (PWV) is a strong predictor of coronary artery disease, the significance of local coronary stiffness has never been tackled. The first objective of this study was to describe a method of measuring coronary PWV (CoPWV) invasively and to describe its determinants. The second objective was to assess both CoPWV and aortic PWV in patients presenting with acute coronary syndromes or stable coronary artery disease. In 53 patients, CoPWV was measured from the delay in pressure wave and distance traveled as a pressure wire was withdrawn from the distal to the proximal coronary segment. Similarly, aortic PWV was measured invasively when the wire was pulled across the ascending aorta; carotid-femoral PWV was also measured noninvasively using the SphygmoCor system (AtCor Medical). Mean CoPWV was 10.3±6.1 m/s. Determinants of increased CoPWV were fractional flow reserve, diastolic blood pressure, and previous stent implantation in the recorded artery. CoPWV was lower in patients with acute coronary syndromes versus stable coronary artery disease (7.6±3 versus 11.5±6.4 m/s; P=0.02), and this persisted after adjustment for confounders. In contrast, aortic stiffness, assessed by aortic and carotid-femoral PWV, did not differ significantly. CoPWV seems associated with acute coronary events more closely than aortic PWV. High coronary compliance, whether per se or because it leads to a distal shift in compliance mismatch, may expose vulnerable plaques to high cyclic stretch. CoPWV is a new tool to assess local compliance at the coronary level; it paves the way for a new field of research. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  10. Skin perfusion pressure measured with a photo sensor in an air-filled plastic balloon: validity and reproducibility on the lower leg in normal subjects and patients suspected of obliterative arterial disease

    International Nuclear Information System (INIS)

    Nielsen, Steen Levin; Nielsen, Anne Lerberg; Vind, Susanne Haase; Thomassen, Anders

    2011-01-01

    An inflatable small plastic bag including a photo sensor was constructed for measurement of skin perfusion pressure avoiding the rim of the photo sensor over bony and tendineous surfaces of the tibia below the knee, at the ankle, and on the dorsal forefoot. Compression was obtained using a conical blood pressure cuff with continuous decrease from suprasystolic arm pressure. The validity of skin perfusion pressure with the new device was compared to that of isotope washout below the knee in normal subjects and in patients with an ischemic forefoot with acceptable agreement. The method had a high reproducibility within and between days in normal subjects. Compared to systolic arterial pressure measured using a strain gauge with a cuff on the ankle in normal subjects and patients with intermittent claudication the new device showed blood pressure in the skin closer to the diastolic pressure. The new pressure device thus had acceptable validity and reproducibility for estimation of the skin perfusion pressure and can be used on bony and tendineous sites on the lower limb in regions where critical wound healing is frequent, e.g. ankle and forefoot

  11. Restoration of myocardial blood flow following percutaneous coronary balloon dilatation and stent implantation: Assessment with qualitative and quantitative contrast-enhanced magnetic resonance imaging

    International Nuclear Information System (INIS)

    Sensky, P.R.; Samani, N.J.; Horsfield, M.A.; Cherryman, G.R.

    2002-01-01

    AIM: To examine the serial use of magnetic resonance imaging (MRI) to evaluate regional myocardial perfusion changes following percutaneous coronary angioplasty and stent implantation (PTCA). MATERIALS AND METHODS: Six patients with single vessel coronary artery disease (CAD) underwent contrast-enhanced first pass MRI immediately prior to (visit A) and within 7 days after (visit B) PTCA. Three sequential short axis slices were obtained after gadodiamide (Gd) bolus (0.025 mmol/kg -1 ) at rest and during adenosine. Each short axis was divided radially into eight regions of interest (ROIs). ROIs were anatomically assigned to a coronary artery territory (CAT). Stress and rest qualitative and quantitative (unidirectional extraction fraction constant (K i ); index of myocardial perfusion reserve (MPRI) = stressK i / restK i ) perfusion parameters were determined for ROI supplied by remote and stenosed/stented vessels for each visit. RESULTS: In stented ROIs the number of ROIs demonstrating normal perfusion, as opposed to reversible perfusion deficits, increased. Qualitative perfusion assessment in remote CATs was unchanged. MPRI in stenotic CATs was lower than in remote CATs at visit A (P < 0.001). Following PTCA, MPRI increased in stented CATs (P < 0.001) but was unchanged in remote CATs. CONCLUSION: Restoration of myocardial perfusion following PTCA can be delineated with qualitative and quantitative perfusion MRI. Although at present the investigation is technically complex and not perfectly sensitive or specific, MRI has the potential to be a valuable tool for patient follow-up and evaluation of revascularization strategy efficacy. Sensky, P.R. et al. (2002)

  12. Dynamic CT myocardial perfusion imaging: detection of ischemia in a porcine model with FFR verification

    Science.gov (United States)

    Fahmi, Rachid; Eck, Brendan L.; Vembar, Mani; Bezerra, Hiram G.; Wilson, David L.

    2014-03-01

    Dynamic cardiac CT perfusion (CTP) is a high resolution, non-invasive technique for assessing myocardial blood ow (MBF), which in concert with coronary CT angiography enable CT to provide a unique, comprehensive, fast analysis of both coronary anatomy and functional ow. We assessed perfusion in a porcine model with and without coronary occlusion. To induce occlusion, each animal underwent left anterior descending (LAD) stent implantation and angioplasty balloon insertion. Normal ow condition was obtained with balloon completely de ated. Partial occlusion was induced by balloon in ation against the stent with FFR used to assess the extent of occlusion. Prospective ECG-triggered partial scan images were acquired at end systole (45% R-R) using a multi-detector CT (MDCT) scanner. Images were reconstructed using FBP and a hybrid iterative reconstruction (iDose4, Philips Healthcare). Processing included: beam hardening (BH) correction, registration of image volumes using 3D cubic B-spline normalized mutual-information, and spatio-temporal bilateral ltering to reduce partial scan artifacts and noise variation. Absolute blood ow was calculated with a deconvolutionbased approach using singular value decomposition (SVD). Arterial input function was estimated from the left ventricle (LV) cavity. Regions of interest (ROIs) were identi ed in healthy and ischemic myocardium and compared in normal and occluded conditions. Under-perfusion was detected in the correct LAD territory and ow reduction agreed well with FFR measurements. Flow was reduced, on average, in LAD territories by 54%.

  13. Effectiveness of Myocardial Contrast Echocardiography Quantitative Analysis during Adenosine Stress versus Visual Analysis before Percutaneous Therapy in Acute Coronary Pain: A Coronary Artery TIMI Grading Comparing Study

    Science.gov (United States)

    Yang, Lixia; Mu, Yuming; Quaglia, Luiz Augusto; Tang, Qi; Guan, Lina; Wang, Chunmei; Shih, Ming Chi

    2012-01-01

    The study aim was to compare two different stress echocardiography interpretation techniques based on the correlation with thrombosis in myocardial infarction (TIMI ) flow grading from acute coronary syndrome (ACS) patients. Forty-one patients with suspected ACS were studied before diagnostic coronary angiography with myocardial contrast echocardiography (MCE) at rest and at stress. The correlation of visual interpretation of MCE and TIMI flow grade was significant. The quantitative analysis (myocardial perfusion parameters: A, β, and A × β) and TIMI flow grade were significant. MCE visual interpretation and TIMI flow grade had a high degree of agreement, on diagnosing myocardial perfusion abnormality. If one considers TIMI flow grade <3 as abnormal, MCE visual interpretation at rest had 73.1% accuracy with 58.2% sensitivity and 84.2% specificity and at stress had 80.4% accuracy with 76.6% sensitivity and 83.3% specificity. The MCE quantitative analysis has better accuracy with 100% of agreement with different level of TIMI flow grading. MCE quantitative analysis at stress has showed a direct correlation with TIMI flow grade, more significant than the visual interpretation technique. Further studies could measure the clinical relevance of this more objective approach to managing acute coronary syndrome patient before percutaneous coronary intervention (PCI). PMID:22778555

  14. Noninvasive physiologic assessment of coronary stenoses using cardiac CT.

    Science.gov (United States)

    Xu, Lei; Sun, Zhonghua; Fan, Zhanming

    2015-01-01

    Coronary CT angiography (CCTA) has become an important noninvasive imaging modality in the diagnosis of coronary artery disease (CAD). CCTA enables accurate evaluation of coronary artery stenosis. However, CCTA provides limited information on the physiological significance of stenotic lesions. A noninvasive "one-stop-shop" diagnostic test that can provide both anatomical significance and functional significance of stenotic lesions would be beneficial in the diagnosis and management of CAD. Recently, with the introduction of novel techniques, such as myocardial CT perfusion, CT-derived fractional flow reserve (FFRCT), and transluminal attenuation gradient (TAG), CCTA has emerged as a noninvasive method for the assessment of both anatomy of coronary lesions and its physiological consequences during a single study. This review provides an overview of the current status of new CT techniques for the physiologic assessments of CAD.

  15. Complete inhibition of creatine kinase in isolated perfused rat hearts

    International Nuclear Information System (INIS)

    Fossel, E.T.; Hoefeler, H.

    1987-01-01

    Transient exposure of an isolated isovolumic perfused rat heart to low concentrations (0.5 mM) of perfusate-born iodoacetamide resulted in complete inhibition of creatine kinase and partial inhibition of glyceraldehyde-3-phosphate dehydrogenase in the heart. At low levels of developed pressure, hearts maintained mechanical function, ATP, and creatine phosphate levels at control values. However, iodoacetamide-inhibited hearts were unable to maintain control values of end diastolic pressure or peak systolic pressure as work load increased. Global ischemia resulted in loss of all ATP without loss of creatine phosphate, indicating lack of active creatine kinase. These results indicate that isovolumic perfused rat hearts are able to maintain normal function and normal levels of high-energy phosphates without active creatine kinase at low levels of developed pressure. 31 P-NMR of the heart was carried out

  16. Dependence of Intramyocardial Pressure and Coronary Flow on Ventricular Loading and Contractility: A Model Study

    NARCIS (Netherlands)

    Bovendeerd, P.H.M.; Borsje, P.; Arts, M.G.J.; Vosse, van de F.N.

    2006-01-01

    The phasic coronary arterial inflow during the normal cardiac cycle has been explained with simple (waterfall, intramyocardial pump) models, emphasizing the role of ventricular pressure. To explain changes in isovolumic and low afterload beats, these models were extended with the effect of

  17. Roles of myocardial blood volume and flow in coronary artery disease: an experimental MRI study at rest and during hyperemia

    International Nuclear Information System (INIS)

    McCommis, Kyle S.; Goldstein, Thomas A.; Pilgram, Thomas; Abendschein, Dana R.; Misselwitz, Bernd; Gropler, Robert J.; Zheng, Jie

    2010-01-01

    To validate fast perfusion mapping techniques in a setting of coronary artery stenosis, and to further assess the relationship of absolute myocardial blood volume (MBV) and blood flow (MBF) to global myocardial oxygen demand. A group of 27 mongrel dogs were divided into 10 controls and 17 with acute coronary stenosis. On 1.5-T MRI, first-pass perfusion imaging with a bolus injection of a blood-pool contrast agent was performed to determine myocardial perfusion both at rest and during either dipyridamole-induced vasodilation or dobutamine-induced stress. Regional values of MBF and MBV were quantified by using a fast mapping technique. Color microspheres and 99m Tc-labeled red blood cells were injected to obtain respective gold standards. Microsphere-measured MBF and 99m Tc-measured MBV reference values correlated well with the MR results. Given the same changes in MBF, changes in MBV are twofold greater with dobutamine than with dipyridamole. Under dobutamine stress, MBV shows better association with total myocardial oxygen demand than MBF. Coronary stenosis progressively reduced this association in the presence of increased stenosis severity. MR first-pass perfusion can rapidly estimate regional MBF and MBV. Absolute quantification of MBV may add additional information on stenosis severity and myocardial viability compared with standard qualitative clinical evaluations of myocardial perfusion. (orig.)

  18. Roles of myocardial blood volume and flow in coronary artery disease: an experimental MRI study at rest and during hyperemia

    Science.gov (United States)

    McCommis, Kyle S.; Goldstein, Thomas A.; Abendschein, Dana R.; Misselwitz, Bernd; Pilgram, Thomas; Gropler, Robert J.

    2010-01-01

    Objective To validate fast perfusion mapping techniques in a setting of coronary artery stenosis, and to further assess the relationship of absolute myocardial blood volume (MBV) and blood flow (MBF) to global myocardial oxygen demand. Methods A group of 27 mongrel dogs were divided into 10 controls and 17 with acute coronary stenosis. On 1.5-T MRI, first-pass perfusion imaging with a bolus injection of a blood-pool contrast agent was performed to determine myocardial perfusion both at rest and during either dipyridamole-induced vasodilation or dobutamine-induced stress. Regional values of MBF and MBV were quantified by using a fast mapping technique. Color microspheres and 99mTc-labeled red blood cells were injected to obtain respective gold standards. Results Microsphere-measured MBF and 99mTc-measured MBV reference values correlated well with the MR results. Given the same changes in MBF, changes in MBV are twofold greater with dobutamine than with dipyridamole. Under dobutamine stress, MBV shows better association with total myocardial oxygen demand than MBF. Coronary stenosis progressively reduced this association in the presence of increased stenosis severity. Conclusions MR first-pass perfusion can rapidly estimate regional MBF and MBV. Absolute quantification of MBV may add additional information on stenosis severity and myocardial viability compared with standard qualitative clinical evaluations of myocardial perfusion. PMID:20182731

  19. SPECT myocardial perfusion imaging. Long-term prognostic value in diabetic patients with and without coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Koehli, M. [Dept. of Endocrinology, Diabetology and Metabolism, Univ. Hospital Lausanne (Switzerland); Dept. of Nuclear Medicine, Univ. Hospital Lausanne (Switzerland); Monbaron, D.; Gaillard, R.C.; Ruiz, J. [Dept. of Endocrinology, Diabetology and Metabolism, Univ. Hospital Lausanne (Switzerland); Prior, J.O.; Bischof Delaloye, A. [Dept. of Nuclear Medicine, Univ. Hospital Lausanne (Switzerland); Calcagni, M.L. [Dept. of Nuclear Medicine, Univ. Hospital Lausanne (Switzerland); Dept. of Cardiology, Univ. Hospital Lausanne (Switzerland); Fivaz-Arbane, M.; Stauffer, J.C. [Inst. of Nuclear Medicine, Univ. Cattolica del Sacro Cuore, Roma (Italy)

    2006-07-01

    Aim: To determine the long-term prognostic value of SPECT myocardial perfusion imaging (MPI) for the occurrence of cardiovascular events in diabetic patients. Patients, methods: SPECT MPI of 210 consecutive Caucasian diabetic patients were analysed using Kaplan-Meier event-free survival curve and independent predictors were determined by Cox multivariate analyses. Results: Follow-up was complete in 200 (95%) patients with a median period of 3.0 years (0.8-5.0). The population was composed of 114 (57%) men, age 65 {+-} 10 years, 181 (90.5%) type 2 diabetes mellitus, 50 (25%) with a history of coronary artery disease (CAD) and 98 (49%) presenting chest pain prior to MPI. The prevalence of abnormal MPI was 58%. Patients with a normal MPI had neither cardiac death, nor myocardial infarction, independently of a history of coronary artery disease or chest pain. Among the independent predictors of cardiac death and myocardial infarction, the strongest was abnormal MPI (p < 0.0001), followed by history of CAD (Hazard Ratio (HR) = 15.9; p = 0.0001), diabetic retinopathy (HR = 10.0; p = 0.001) and inability to exercise (HR = 7.7; p = 0.02). Patients with normal MPI had a low revascularisation rate of 2.4% during the follow-up period. Compared to normal MPI, cardiovascular events increased 5.2 fold for reversible defects, 8.5 fold for fixed defects and 20.1 fold for the association of both defects. Conclusion: Diabetic patients with normal MPI had on excellent prognosis independently of history of CAD. On the opposite, an abnormal MPI led to a > 5-fold increase in cardiovascular events. This emphasizes the value of SPECT MPI in predicting and risk-stratifying cardiovascular events in diabetic patients. (orig.)

  20. Nuclear Cardiology in Acute Coronary Syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Paeng, Jin Chul; Lee, Dong Soo [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2009-06-15

    Nuclear myocardial perfusion imaging is very effective in the evaluation of patients with suspicious acute coronary syndrome (ACS), for adequate diagnosis and treatment. There have been many clinical evidences to support the efficacy and cost-effectiveness. In addition, many authoritative guidelines support the utility of myocardial perfusion imaging in ACS with an appropriate diagnostic protocol. However, with the development of other cardiac imaging modalities, the choice of modality for the diagnosis of suspicious ACS now depends on the availability of each modality in each institute. Newly developed imaging technologies, especially including molecular imaging, are expected to have great potential not only for diagnosis but also for primary, secondary, and tertiary prevention of ACS.

  1. Nuclear Cardiology in Acute Coronary Syndrome

    International Nuclear Information System (INIS)

    Paeng, Jin Chul; Lee, Dong Soo

    2009-01-01

    Nuclear myocardial perfusion imaging is very effective in the evaluation of patients with suspicious acute coronary syndrome (ACS), for adequate diagnosis and treatment. There have been many clinical evidences to support the efficacy and cost-effectiveness. In addition, many authoritative guidelines support the utility of myocardial perfusion imaging in ACS with an appropriate diagnostic protocol. However, with the development of other cardiac imaging modalities, the choice of modality for the diagnosis of suspicious ACS now depends on the availability of each modality in each institute. Newly developed imaging technologies, especially including molecular imaging, are expected to have great potential not only for diagnosis but also for primary, secondary, and tertiary prevention of ACS

  2. Value of heart-lung ratio of 99Tcm N-NOET in detection of coronary artery disease

    International Nuclear Information System (INIS)

    Zhang Wanchun; Li Sijin; Liu Jianzhong; Hu Guang; Wang Jin; Lv Jiyuan

    2005-01-01

    To investigate the relationship between the heart-lung ratio (HLR) assessed with exercise 99 Tc m N-NOET myocardial perfusion imaging and coronary artery disease (CAD), 10 normal volunteers (7 male and 3 female, aged 40.0 ± 5.8 years), and 40 suspected CAD patients (21 male and 19 female, aged 55.2 ± 8.5 years) underwent exercise (30 min)-delayed (2 and 4 h postinjection) 99 Tc m -NOET gated myocardial perfusion imaging, and the HLR at different time was calculated. 13 patients among them took the coronary angiography in two months. According to the exercise heart-lung ratio (EXHLR), 50 subjects were divided into two groups. G1(n=36, EXHLR≥2) included 10 normal volunteers, 5 patients with normal coronary arteries, and the rest 21 patients had no relevant symptom and cardiac event in the follow-up period of 4 to 12 months. The image was normal in all of the subjects in G1. In G2 (n=14, EXHLR 99 Tc m N-NOET may be useful as a diagnostic index in CAD because it is more sensitive than myocardial perfusion imaging. (authors)

  3. Visualization of the coronary arteries. 6

    International Nuclear Information System (INIS)

    Koch, M.; Von Schulthess, G.K.

    1991-01-01

    Since MRI is very sensitive to motion, flow and perfusion, in addition to its ability to depict detailed morphology, it has many excellent advantages as a tool for studying vascular structures. These include its noninvasive nature, excellent and to a large degree user adjustable contrast between flowing blood and cardiovascular structures, and the ability to produce direct images in any plane. The coronary arteries can be identified in their proximal parts when imaging is done using sections perpendicular to the aortic root, more distally located portions are detected inconsistently and should not be confounded with cardiac veins. With gradient-echo imaging and MR angiograpic (MRA) methods the coronaries can be visualized well, because their is a positive, rather than a negative vascular contrast as found in spin-echo (SE) images. With regard to coronary artery imaging, to date MRA does not challenge the primary role of conventional coronary angiography. Conventional angiograms have superior spatial resolution and are less sensitive to degradation by flow disturbances. Current MRA is a purely experimental procedure and MRI of the coronary vessels is a research endeavour. (author). 32 refs.; 7 figs

  4. Myocardial perfusion scintigraphy in Germany in 2009: utilization and state of the practice

    Energy Technology Data Exchange (ETDEWEB)

    Lindner, Oliver; Burchert, Wolfgang [University Hospital of the Ruhr University Bochum, Institute of Radiology, Nuclear Medicine and Molecular Imaging, Heart and Diabetes Centre North Rhine-Westphalia, Bad Oeynhausen (Germany); Bengel, Frank M. [Hanover University School of Medicine, Department of Nuclear Medicine, Hannover (Germany); Zimmermann, Rainer [Klinikum Pforzheim GmbH, Cardiology Department, Pforzheim (Germany); Dahl, Juergen vom [Kliniken Maria Hilf GmbH, Cardiology Department, Moenchengladbach (Germany); Schaefers, Michael [Westfaelische Wilhelms Universitaet Muenster, European Institute of Molecular Imaging, Muenster (Germany)

    2011-08-15

    Since 2006, the working group Cardiovascular Nuclear Medicine of the German Society of Nuclear Medicine, in cooperation with the working group Nuclear Cardiology of the German Cardiac Society, has been surveying the utilization and technical realization of myocardial perfusion scintigraphy (MPS) in Germany. This paper presents the results of the reporting year 2009. A total of 291 centres participated in the inquiry, including 179 private practices (PP), 86 hospitals (HO) and 26 university hospitals (UH). MPS of 98,103 patients were reported. The MPS numbers per million population (pmp) were estimated at 2,360; 76% of the MPS were performed in PP, 17% in HO and 7% in UH. The ratio of MPS to coronary angiography to revascularization was 0.5 to 2.3 to 1. Data from 134 centres which participated in the surveys from 2005 to 2009 showed a decrease in MPS utilization of 2.2%. Nearly half of the MPS were requested by ambulatory care cardiologists. Of all MPS studies, 89% were conducted with {sup 99m}Tc perfusion tracers. Ergometry was the preferred stress test (69%). Adenosine was used in 16%, adenosine + exercise in 7%, dipyridamole in 3%, dipyridamole + exercise in 5% and dobutamine in <1%. Gated single proton emission computed tomography (SPECT) acquisition was performed in 56% of all rest MPS and in 56% of all stress MPS. Both rest and stress MPS were ECG gated in 41%. Only 33% of the centres always performed a quantification of the perfusion studies, whereas 51% did not apply any quantification; 4% of the MPS studies were corrected for attenuation, and 17 centres used transmission sources of 12 CT-based systems. A scan activity of 2,380 MPS pmp is in the upper third of the European range. The ratios to coronary angiography and to revascularization suggest that angiography dominates diagnosis and management of coronary artery disease (CAD). The clinical and technical realizations reveal that the predominant goals of further trainings to optimize MPS are in the field

  5. Behavior patterns and coronary heart disease

    Science.gov (United States)

    Townsend, J. C.; Cronin, J. P.

    1975-01-01

    The relationships between two behavioral patterns, cardiac risk factors, and coronary heart disease are investigated. Risk factors used in the analysis were family history of coronary disease, smoking, cholesterol, obesity, systotic blood pressure, diastolic blood pressure, blood sugar, uric acid, erythrocyte sedimentation rate, and white blood unit. It was found that conventional, non-behavioral pattern risk factors alone were not significantly related to coronary heart disease.

  6. Combined use of 64-slice computed tomography angiography and gated myocardial perfusion SPECT for the detection of functionally relevant coronary artery stenoses. First results in a clinical setting concerning patients with stable angina

    International Nuclear Information System (INIS)

    Hacker, M.; Hack, N.; Tiling, R.; Jakobs, T.; Nikolaou, K.; Becker, C.; Ziegler, F. von; Knez, A.; Koenig, A.; Klauss, V.

    2007-01-01

    Aim: In patients with stable angina pectoris both morphological and functional information about the coronary artery tree should be present before revascularization therapy is performed. High accuracy was shown for spiral computed tomography (MDCT) angiography acquired with a 64-slice CT scanner compared to invasive coronary angiography (ICA) in detecting obstructive'' coronary artery disease (CAD). Gated myocardial SPECT (MPI) is an established method for the noninvasive assessment of functional significance of coronary stenoses. Aim of the study was to evaluate the combination of 64-slice CT angiography plus MPI in comparison to ICA plus MPI in the detection of hemodynamically relevant coronary artery stenoses in a clinical setting. Patients, methods: 30 patients (63 ± 10.8 years, 23 men) with stable angina (21 with suspected, 9 with known CAD) were investigated. MPI, 64-slice CT angiography and ICA were performed, reversible and fixed perfusion defects were allocated to determining lesions separately for MDCT angiography and ICA. The combination of MDCT angiography plus MPI was compared to the results of ICA plus MPI. Results: Sensitivity, specificity, negative and positive predictive value for the combination of MDCT angiography plus MPI was 85%, 97%, 98% and 79%, respectively, on a vessel-based and 93%, 87%, 93% and 88%, respectively, on a patient-based level. 19 coronary arteries with stenoses =50% in both ICA and MDCT angiography showed no ischemia in MPI. Conclusion: The combination of 64-slice CT angiography and gated myocardial SPECT enabled a comprehensive non-invasive view of the anatomical and functional status of the coronary artery tree. (orig.)

  7. Combined use of 64-slice computed tomography angiography and gated myocardial perfusion SPECT for the detection of functionally relevant coronary artery stenoses. First results in a clinical setting concerning patients with stable angina

    Energy Technology Data Exchange (ETDEWEB)

    Hacker, M.; Hack, N.; Tiling, R. [Klinikum Grosshadern (Germany). Dept. of Nuclear Medicine; Jakobs, T.; Nikolaou, K.; Becker, C. [Klinikum Grosshadern (Germany). Dept. of Clinical Radiology; Ziegler, F. von; Knez, A. [Klinikum Grosshadern (Germany). Dept. of Cardiology; Koenig, A.; Klauss, V. [Medizinische Poliklinik-Innenstadt, Univ. of Munich (Germany). Dept. of Cardiology

    2007-07-01

    Aim: In patients with stable angina pectoris both morphological and functional information about the coronary artery tree should be present before revascularization therapy is performed. High accuracy was shown for spiral computed tomography (MDCT) angiography acquired with a 64-slice CT scanner compared to invasive coronary angiography (ICA) in detecting ''obstructive'' coronary artery disease (CAD). Gated myocardial SPECT (MPI) is an established method for the noninvasive assessment of functional significance of coronary stenoses. Aim of the study was to evaluate the combination of 64-slice CT angiography plus MPI in comparison to ICA plus MPI in the detection of hemodynamically relevant coronary artery stenoses in a clinical setting. Patients, methods: 30 patients (63 {+-} 10.8 years, 23 men) with stable angina (21 with suspected, 9 with known CAD) were investigated. MPI, 64-slice CT angiography and ICA were performed, reversible and fixed perfusion defects were allocated to determining lesions separately for MDCT angiography and ICA. The combination of MDCT angiography plus MPI was compared to the results of ICA plus MPI. Results: Sensitivity, specificity, negative and positive predictive value for the combination of MDCT angiography plus MPI was 85%, 97%, 98% and 79%, respectively, on a vessel-based and 93%, 87%, 93% and 88%, respectively, on a patient-based level. 19 coronary arteries with stenoses =50% in both ICA and MDCT angiography showed no ischemia in MPI. Conclusion: The combination of 64-slice CT angiography and gated myocardial SPECT enabled a comprehensive non-invasive view of the anatomical and functional status of the coronary artery tree. (orig.)

  8. Technetium myocardial perfusion scanning in prerenal transplant evaluation in the United kingdom.

    LENUS (Irish Health Repository)

    Wong, C F

    2008-06-01

    Because death with a functioning graft remains one of the most important causes of long-term renal transplant failure, cardiac risk stratification and screening for coronary artery disease are essential components of pretransplant assessment. Pretransplant screening for occult coronary artery disease in a subset of these patients may improve outcome. The UK follows the European Best practice guideline 1.5.5 E. Although echocardiography, thallium myocardial perfusion scanning (MPS), dobutamine stress echocardiography, and coronary angiography have been suggested as means of cardiovascular assessment, the best means of assessment remains undetermined. Therefore, we investigated the role of 99m technetium sestamibi myocardial perfusion scanning as an assessment tool for identifying those patients with end-stage renal failure at high risk of cardiovascular death after renal transplantation. Retrospectively, we studied 126 patients that had a MPS as part of their pretransplant assessment. Overall unadjusted survival was 65% at 3 years. Twelve deaths resulted from cardiovascular causes. A reversible defect on MPS was associated with a fatal cardiac event and all-cause mortality. The unadjusted hazard ratio of cardiac event with reversible defect on MPS was 3.1 (95% confidence interval, 1.1 to 18.2) and hazard ratio of death with reversible defect on MPS was 1.92 (95% confidence interval, 1.1 to 4.4). Thus, MPS may be a useful tool in cardiac risk stratification and in selecting patients with a favorable outcome after renal transplantation. Our patients with a reversible defect in particular have increased cardiac mortality. This group may benefit from coronary angiography.

  9. Limitations of regional myocardial thallium clearance for identification of disease in individual coronary arteries

    International Nuclear Information System (INIS)

    Becker, L.C.; Rogers, W.J. Jr.; Links, J.M.; Corn, C.

    1989-01-01

    The purpose of this study was to critically evaluate the usefulness of postexercise regional myocardial thallium-201 clearance for identifying disease in individual coronary arteries. Exercise and redistribution planar imaging studies were performed in 114 subjects, including 19 normal volunteers and 95 patients undergoing cardiac catheterization (70 with and 25 without greater than or equal to 50% narrowing in one or more coronary arteries). Thallium clearance was measured from predefined myocardial regions corresponding to the left anterior descending, left circumflex and right coronary arteries and was expressed as the percent decrease in activity at 4 h, assuming monoexponential clearance. In regions perfused by a normal or insignificantly diseased coronary artery, mean 4 h clearance was 58.9 +/- 9.4% for normal volunteers, 43.1 +/- 15.5% for catheterized patients without coronary artery disease and 36.3 +/- 24.9% for catheterized patients with coronary artery disease (p less than 0.001 patients with coronary artery disease versus normal volunteers). Clearance from normal regions was significantly associated with two measures of exercise performance: percent of predicted maximal heart rate achieved (r = 0.49) and exercise duration (r = 0.35). In regions perfused by a stenotic coronary artery, mean clearance was lower (31.1 +/- 19.8%) but was not significantly different from that in normal regions in the same patients. Clearance from diseased regions was also associated with maximal exercise heart rate (r = 0.28) and exercise duration (r = 0.41), but not with percent coronary artery stenosis (r = 0.02). After taking exercise performance into account, the number of diseased vessels or the presence or absence of disease in a given vessel had little influence on regional thallium clearance

  10. Aid in the detection of myocardial perfusion abnormality utilizing SPECT atlas and images registration: preliminary results

    International Nuclear Information System (INIS)

    Padua, Rodrigo Donizete Santana de; Oliveira, Lucas Ferrari de; Marques, Paulo Mazzoncini de Azevedo; Groote, Jean-Jacques Georges Soares de; Castro, Adelson Antonio de; Ana, Lauro Wichert; Simoes, Marcus Vinicius

    2008-01-01

    To develop an atlas of myocardial perfusion scintigraphy and evaluating its applicability in computer-aided detection of myocardial perfusion defects in patients with ischemic heart disease. The atlas was created with rest-stress myocardial perfusion scintigraphic images of 20 patients of both genders with low probability of coronary artery disease and considered as normal by two experienced observers. Techniques of image registration and mathematical operations on images were utilized for obtaining template images depicting mean myocardial uptake and standard deviation for each gender and physiological condition. Myocardial perfusion scintigraphy images of one male and one female patient were aligned with the corresponding atlas template image, and voxels with myocardial uptake rates two standard deviations below the mean voxel value of the respective region in the atlas template image were highlighted on the tomographic sections and confirmed as perfusion defects by both observe. The present study demonstrated the creation of an atlas of myocardial perfusion scintigraphy with promising results of this tool as an aid in the detection of myocardial perfusion defects. However, further prospective validation with a more representative sample is recommended. (author)

  11. Aid in the detection of myocardial perfusion abnormality utilizing SPECT atlas and images registration: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Padua, Rodrigo Donizete Santana de [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Div. de Cardiologia]. E-mail: rodrigo_dsp@hcrp.fmrp.usp.br; Oliveira, Lucas Ferrari de [Universidade Federal de Pelotas (UFPel), RS (Brazil). Inst. de Fisica e Matematica. Dept. de Tecnologia da Informacao; Marques, Paulo Mazzoncini de Azevedo [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Centro de Ciencias das Imagens e Fisica Medica; Groote, Jean-Jacques Georges Soares de [Instituto de Ensino Superior COC, Ribeirao Preto, SP (Brazil). Lab. of Artifical Intelligence and Applications; Castro, Adelson Antonio de [Universidade de Sao Paulo (USP), Ribeirao Preto, SP, (Brazil). Faculdade de Medicina; Ana, Lauro Wichert [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Centro de Ciencias das Imagens e Fisica Medica; Simoes, Marcus Vinicius [Universidade de Sao Paulo (USP), Ribeirao Preto, SP, (Brazil). Faculdade de Medicina. Divisao de Cardiologia

    2008-11-15

    To develop an atlas of myocardial perfusion scintigraphy and evaluating its applicability in computer-aided detection of myocardial perfusion defects in patients with ischemic heart disease. The atlas was created with rest-stress myocardial perfusion scintigraphic images of 20 patients of both genders with low probability of coronary artery disease and considered as normal by two experienced observers. Techniques of image registration and mathematical operations on images were utilized for obtaining template images depicting mean myocardial uptake and standard deviation for each gender and physiological condition. Myocardial perfusion scintigraphy images of one male and one female patient were aligned with the corresponding atlas template image, and voxels with myocardial uptake rates two standard deviations below the mean voxel value of the respective region in the atlas template image were highlighted on the tomographic sections and confirmed as perfusion defects by both observe. The present study demonstrated the creation of an atlas of myocardial perfusion scintigraphy with promising results of this tool as an aid in the detection of myocardial perfusion defects. However, further prospective validation with a more representative sample is recommended. (author)

  12. SPET in cardiology. Diagnosis, prognosis and management of patients with coronary artery disease

    International Nuclear Information System (INIS)

    Tamaki, N.; Morita, K.

    2005-01-01

    Stress myocardial perfusion imaging has been considered as a most valuable means for diagnosis and treatment strategy in patients with suspected and known coronary artery disease. 99m TC perfusion imaging agents provide excellent myocardial perfusion images. In addition, greater photon flux from the tracer permits simultaneous assessment of regional perfusion and function with use ECG-gated acquisition. Gated SPET imaging technique has a potential for higher diagnostic accuracy for diagnosis of coronary artery disease and assessment of the disease severity. In addition, radionuclide imaging plays an important role to differentiate reversible ischemic myocardium which may improve LV function after revascularization from irreversible scar in patients with history of myocardial infraction. While FDG-PET is considered as a most reliable means for myocardial assessment, SPET imaging has been widely used for the viability assessment, with gaining higher accuracy for predicting reversible ischemia. Recently a variety of new radiopharmaceutical agents have been introduced to probe myocardial function 'in vivo' ( 123 I)BMIPP, a branched fatty acid analog, has been used for metabolic imaging using SPET. Less uptake of BMIPP than perfusion is often observed in the ischemic myocardium. Such a perfusion metabolic mismatch which seems to be similarly observed in FDG-PET is identified in the stunned or hibernating myocardium with regional dysfunctions. Severe ischemia is identified as reduced BMIPP uptake at rest, suggesting its role as an ischemic memory imaging. These new techniques will provide insights into new pathological states in the ischemic heart disease and enable to select optimal treatment of these patients

  13. Relationships Between Components of Blood Pressure and Cardiovascular Events in Patients with Stable Coronary Artery Disease and Hypertension.

    Science.gov (United States)

    Vidal-Petiot, Emmanuelle; Greenlaw, Nicola; Ford, Ian; Ferrari, Roberto; Fox, Kim M; Tardif, Jean-Claude; Tendera, Michal; Parkhomenko, Alexander; Bhatt, Deepak L; Steg, P Gabriel

    2018-01-01

    Observational studies have shown a J-shaped relationship between diastolic blood pressure (BP) and cardiovascular events in hypertensive patients with coronary artery disease. We investigated whether the increased risk associated with low diastolic BP reflects elevated pulse pressure (PP). In 22 672 hypertensive patients with coronary artery disease from the CLARIFY registry (Prospective Observational Longitudinal Registry of Patients With Stable Coronary Artery Disease), followed for a median of 5.0 years, BP was measured annually and averaged. The relationships between PP and diastolic BP, alone or combined, and the primary composite outcome (cardiovascular death or myocardial infarction) were analyzed using multivariable Cox proportional hazards models. Adjusted hazard ratios for the primary outcome were 1.62 (95% confidence interval [CI], 1.40-1.87), 1.00 (ref), 1.07 (95% CI, 0.94-1.21), 1.54 (95% CI, 1.32-1.79), and 2.34 (95% CI, 1.95-2.81) for PPhypertensive patients with coronary artery disease persists in patients within the lowest-risk PP range and is therefore unlikely to be solely the consequence of an increased PP reflecting advanced vascular disease. URL: http://www.clarify-registry.com. Unique identifier: ISRCTN43070564. © 2017 American Heart Association, Inc.

  14. Rest/stress myocardial perfusion imaging: A means to prevent missed acute ischemic coronary syndrome diagnoses

    International Nuclear Information System (INIS)

    Fink-Bennett, D.; Pattekar, A.M.

    2002-01-01

    Aim: The sensitivity and specificity of rest/stress (R/S) myocardial perfusion imaging (MPI) in detecting an acute ischemic coronary syndrome (AICS) was determined in 100 consecutive patients (pts) admitted to the Chest Pain Clinic-Observation Unit (CPC-OU) with chest pain (CP) of suspected cardiac etiology and a negative (neg) or non diagnostic (dx) EKG. There were 57 females and 43 males, 30-83 years of age. 50 studies were performed from 1/15/98 to 4/2/98; 50 from 11/19/99 to 1/10/00. Material and Methods: An AICS was deemed present if a reversible perfusion defect was demonstrated scintigraphically; a ?50% luminal narrow angiographically. No AICS if the pt had a normal R/S MPI, a fixed defect with normal wall motion and thickening, a neg cardiac catheterization, or was free of cardiac symptoms and had no history of a vascular event for 2-3 years post CPC-OU admission. 13 pts with a positive MPI had a cardiac catheterization, none with a neg MPI. SPECT rest MPI's were performed 30-90 minutes (mins) post 10.0 mCi of technetium 99m Sestamibi. SPECT stress MPI's were performed following a 6-8 hour acute myocardial infarction enzyme (CP-MB/Troponin 1) rule out and 30-90 mins post 30.0 mCi of technetium 99m Sestamibi. Results: 29 pts were lost to follow-up. There were 12 true positive, 5 false positive, 54 true negative and 0 false negative studies. The sensitivity, specificity, positive and negative predictive value of a R/S MPI in detecting an AICS is 100%, 91%, 70% and 100%, respectively. An AICS was detected in 12% of pts admitted to the CPC-OU; a finding that correlates with its reported incidence of 2-12%. 6 were managed medically, 3 required emergent bypass surgery, 3 were stented. Conclusion: R/S MPI should be included in the CPC-OU dx work-up of pts with CP of suspected cardiac etiology to prevent missed AICS diagnoses. Patient care will be optimized and health care and medical malpractice awards for failure to diagnosis an acute myocardial infarction

  15. Quantitative thallium-201 single-photon emission computed tomography during maximal pharmacologic coronary vasodilation with adenosine for assessing coronary artery disease

    International Nuclear Information System (INIS)

    Nishimura, S.; Mahmarian, J.J.; Boyce, T.M.; Verani, M.S.

    1991-01-01

    The diagnostic value of maximal pharmacologic coronary vasodilation with intravenously administered adenosine in conjunction with thallium-201 single-photon emission computed tomography (SPECT) for detection of coronary artery disease was investigated in 101 consecutive patients who had concomitant coronary arteriography. Tomographic images were assessed visually and from computer-quantified polar maps of the thallium-201 distribution. Significant coronary artery disease, defined as greater than 50% luminal diameter stenosis, was present in 70 patients. The sensitivity for detecting patients with coronary artery disease using quantitative analysis was 87% in the total group, 82% in patients without myocardial infarction and 96% in those with prior myocardial infarction; the specificity was 90%. The sensitivity for diagnosing coronary artery disease in patients without infarction with single-, double-and triple-vessel disease was 76%, 86% and 90%, respectively. All individual stenoses were identified in 68% of patients with double-vessel disease and in 65% of those with triple-vessel disease. The extent of the perfusion defects, as quantified by polar maps, was directly related to the extent of coronary artery disease. In conclusion, quantitative thallium-201 SPECT during adenosine infusion has high sensitivity and specificity for diagnosing the presence of coronary artery disease, localizing the anatomic site of coronary stenosis and identifying the majority of affected vascular regions in patients with multivessel involvement

  16. Impact of the Absolute Difference in Diastolic Blood Pressure Between Arms in Patients With Coronary Artery Disease

    OpenAIRE

    Hitaka, Yuka; Miura, Shin-ichiro; Koyoshi, Rie; Shiga, Yuhei; Miyase, Yuiko; Norimatsu, Kenji; Nakamura, Ayumi; Adachi, Sen; Kuwano, Takashi; Sugihara, Makoto; Ike, Amane; Nishikawa, Hiroaki; Saku, Keijiro

    2015-01-01

    Background We investigated the relationship between the severity and presence of coronary artery disease (CAD) and a difference in systolic and diastolic blood pressure (SBP and DBP) between arms or between lower limbs. Methods We enrolled 277 patients who underwent coronary angiography. We calculated the absolute (|right BP (rt. BP) - left BP (lt. BP)|) and relative (rt. BP - lt. BP) differences in SBP or DBP between arms or between lower limbs, and assessed the severity of CAD in terms of t...

  17. Noninvasive Physiologic Assessment of Coronary Stenoses Using Cardiac CT

    Directory of Open Access Journals (Sweden)

    Lei Xu

    2015-01-01

    Full Text Available Coronary CT angiography (CCTA has become an important noninvasive imaging modality in the diagnosis of coronary artery disease (CAD. CCTA enables accurate evaluation of coronary artery stenosis. However, CCTA provides limited information on the physiological significance of stenotic lesions. A noninvasive “one-stop-shop” diagnostic test that can provide both anatomical significance and functional significance of stenotic lesions would be beneficial in the diagnosis and management of CAD. Recently, with the introduction of novel techniques, such as myocardial CT perfusion, CT-derived fractional flow reserve (FFRCT, and transluminal attenuation gradient (TAG, CCTA has emerged as a noninvasive method for the assessment of both anatomy of coronary lesions and its physiological consequences during a single study. This review provides an overview of the current status of new CT techniques for the physiologic assessments of CAD.

  18. Role of adenosine 99MTc sestamibi myocardial perfusion spect in evaluation of symptomatic hypertensives with recent onset left bundle branch block

    International Nuclear Information System (INIS)

    Padma, S.; Sundaram, P.S.; Zachariah, M.; Hariads, K.K.

    2004-01-01

    Objectives: Adenosine pharmacological stress Myocardial Perfusion Imaging (AMPI) is the preferred imaging modality for IHD evaluation in pts with Left Bundle Branch Block (LBBB). Good prognosis has been reported in recent onset LBBB pts with normal MPI. Our aim was to evaluate the utility and analyze the predictive value of SestaMIBI AMPI in symptomatic recent onset LBBB hypertensives for coronary artery disease evaluation. Methods: 29 hypertensive pts, age range 36-72yrs, mean 54+ 6 yrs, M:F- 21:8 with recent onset complete LBBB, under evaluation for typical/atypical angina who had AMPI between Nov 02-Nov 03, were retrospectively analyzed. LBBB was diagnosed ECG wise if there is prolonged QRS complex i.e. 0.125sec or more in sinus/supraventricular rhythm, a QS or rS complex in lead 1, and an R-wave peak time of 0.06sec in leads 1, V5 or V6 with no Q wave in same lead. Pts with prior Myocardial Infarct / revasularisation, pacemaker induced LBBB were excluded. Single day 6 min. Adenosine infusion Stress-rest 99m Tc MIBI gated MPI was performed with a dual head variable angle Gamma Camera at 76-degree angle. Coronary Angiogram (CAG) correlation was available in 24 pts. Results: Myocardial perfusion SPECT images were assessed visually and by a 20-segment model. Location, extent and severity of the LV perfusion defects were evaluated. 6/29 pts (20.7%) had normal stress-rest perfusion in all LV segments.12 (41.4%) had isolated septal fixed defect with normal perfusion in rest of the segments.3 pts (10.3%)showed isolated reversible septal defects while 8(27.6%) had reversible septal defects with reversible defects in other LV segments also. Pts with fixed septal perfusion defect showed moderate to good septal wall thickening in gated SPECT images. While all pts with multiple reversible perfusion defects had angiographically proven coronary artery disease (i.e. 3pts had LAD lesion, 2 had Triple vessel and 3 showed double vessel lesions), 1 out of 3 pts with isolated

  19. Correlation of the myocardial perfusion corrected by attenuation with the coronariography. Preliminary results

    International Nuclear Information System (INIS)

    Garcia C, S.E.; Garcia O, R.

    2005-01-01

    The attenuation that suffers the radiation in the soft tissues of the hinders the appropriate interpretation of the myocardial perfusion studies, for what have been implemented attenuation correction systems to reduce the attenuation for soft tissues and to provide myocardial perfusion images more accurate in the diagnosis of coronary illness. The objective was to evaluate the utility of an attenuation correction system (with source of Gadolinium 153) to minimize the devices that look like true defects of myocardial perfusion, caused by soft tissues (mammary tissue, thoracic wall, abdomen, left hemi diaphragm), and to compare those interpretations of the studies with the interpretations of the corresponding coronariographies. The method consists of 95 electronic files which were revised with the concept of heart catheterization, being identified 20 patients from the masculine sex to those that underwent coronariography among May 1999 and December 2002, and that they had study of myocardial perfusion in a maximum period of 3 months foresaw to the invasive procedure. (Author)

  20. Association between left ventricular perfusion defects and myocardial deformation indexes in heart transplantation recipients.

    Science.gov (United States)

    D'Andrea, Antonello; De Rimini, Maria Luisa; America, Raffaella; Cirillo, Chiara; Riegler, Lucia; Limongelli, Giuseppe; D'Alto, Michele; Salerno, Gemma; Maiello, Ciro; Muto, Pietro; Russo, Maria Giovanna; Calabrò, Raffaele; Bossone, Eduardo; Pacileo, Giuseppe

    2017-10-01

    The aim of the study was to analyze possible correlations between strain echocardiography (STE) and PET myocardial perfusion in a population of heart transplantation (HTx) recipients showing preserved left ventricular (LV) ejection fraction. By STE, LV global longitudinal strain (LV GLS) was lower in HTx. PET showed no transient or chronic ischemia in 83 of 115 HTx (73%). Fixed perfusion defects were observed in 17% of HTx and reversible ischemia in 10%. Significant coronary stenosis was observed only in 10 cases. GLS was independently associated with age at HTx and fixed perfusion defects (HR 0.41; P<.001). Such relationships underline STE ability to early identify HTx pts with subclinical myocardial dysfunction during long-term follow-up. © 2017, Wiley Periodicals, Inc.