WorldWideScience

Sample records for coronary by-pass operations

  1. Magnesium sulphate and amiodarone prophylaxis for prevention of postoperative arrhythmia in coronary by-pass operations

    Directory of Open Access Journals (Sweden)

    Huysal Kagan

    2009-02-01

    Full Text Available Abstract Background The aim of this study was to investigate the use of prophylactic magnesium sulphate and amiodarone in treating arrhythmias that may occur following coronary bypass grafting operations. Methods The study population consisted of 192 consecutive patients who were undergoing coronary artery bypass grafting (CABG. Sixty-four patients were given 3 g of magnesium sulphate (MgSO4 [20 ml = 24.32 mEq/L Mg+2] in 100 cc of isotonic 0.9% solution over 2 hours intravenously at the following times: 12 hours prior to the operation, immediately following the operation, and on postoperative days 1, 2, and 3 (Group 1. Another group of 64 patients was given a preoperative infusion of amiodarone (1200 mg on first post-operative day (Group 2. After the operation amiodarone was administered orally at a dose of 600 mg/day. Sixty-four patients in group 3 (control group had 100 cc. isotonic 0.9% as placebo, during the same time periods. Results In the postoperative period, the magnesium values were significantly higher in Group 1 than in Group 2 for all measurements. The use of amiodarone for total arrhythmia was significantly more effective than prophylactic treatment with magnesium sulphate (p = 0.015. There was no difference between the two drugs in preventing supraventricular arrhythmia, although amiodarone significantly delayed the revealing time of atrial fibrillation (p = 0.026. Ventricular arrhythmia, in the form of ventricular extra systole, was more common in the magnesium prophylaxis group. The two groups showed no significant differences in other operative or postoperative measurements. No side effects of the drugs were observed. Conclusion Prophylactic use of magnesium sulphate and amiodarone are both effective at preventing arrhythmia that may occur following coronary by-pass operations. Magnesium sulphate should be used in prophylactic treatment since it may decrease arrhythmia at low doses. If arrhythmia should occur despite this

  2. The impact of avoiding cardiopulmonary by-pass during coronary artery bypass surgery in elderly patients: the Danish On-pump Off-pump Randomisation Study (DOORS)

    DEFF Research Database (Denmark)

    Houlind, Kim; Kjeldsen, Bo Juul; Madsen, Susanne Nørgaard

    2009-01-01

    BACKGROUND: Coronary Artery Bypass Graft operation for ischemic heart disease provides improved quality of life and, in some patients, prolonged survival. Concern has, however, been raised about complications that may be related to the use of cardiopulmonary by-pass (CPB) and aortic cross......-clamping. It has been hypothesized that when coronary artery by-pass grafting is performed without the use of CPB, the rate of serious complications is reduced. METHODS/DESIGN: The trial is designed as an open, randomized, controlled, clinical trial with blinded assessment of end-points. Patients at or above 70...... years of age, referred for surgical myocardial revascularisation, are included and randomised to receive coronary artery by-pass grafting either with or without the use of CPB and aortic cross-clamping. Follow-up is performed by clinical, biochemical, electrocardiographic, and angiographic data...

  3. The management of impending myocardial infarction using coronary artery by-pass grafting and an intra-aortic balloon pump.

    Science.gov (United States)

    Harris, P L; Woollard, K; Bartoli, A; Makey, A R

    1980-01-01

    Of 33 patients with impending myocardial infarction 25 were treated using a combination of coronary artery by-pass grafting and intra-aortic balloon pumping. Eight patients were treated with coronary artery by-pass grafting alone. Twenty-two of the 25 patients who were treated with the combined technique made a full recovery. Three patients sustained definite myocardial infarctions and one of these died. Five of the 8 patients treated by grafting alone suffered infarction and of these 3 died. The value of intra-aortic balloon pumping in combination with coronary artery by-pass grafting in the management of impending myocardial infarction is discussed.

  4. First-pass perfusion disturbance of coronary artery stenosis: an experimental study using MR imaging with Gd-DTPA enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Kyung Il; Lee, Young Ju [Ajou Univ. College of Medicine, Seoul (Korea, Republic of); Lim, Tae Hwan [Ulsan Univ. College of Medicine, Ulsan (Korea, Republic of)] [and others

    1997-11-01

    In order to determine the value of first-pass MR imaging in the diagnosis of myocardial ischemia, first-pass perfusion abnormality of coronary artery stenosis was observed in MRI after gadopentate dimeglumine(GD-DTPA) enhancement. The left anterior descending(LAD) coronary arteries of six dogs were subjected to approximately 70% stenosis confirmed by coronary angiography. Half an hour after adenosine and {sup 99m}Tc-sestamibi infusion, Gd-DTPA(0.2mmol/kg) and methylene blue were administered and termination was induced with potassium chloride. SE T1-weighted and single-photon emission computed tomography(SPECT) images were subsequently obtained and the findings of perfusion defect compared with specimen stain. Three dimensionally reconstructed MR images were used to measure signal intensity(SI) of normal myocardium and perfusion defect from their sectional and total volume. Five of six dogs with LAD artey stenosis ranging from 66% to 73% displayed perfusion defect on MRI, SPECT, and specimen stain, but the remaining dog with stenosis of 58% showed no such defect. MRI showed the perfusion defect as distinct low SI, enabling the measurement of percentage perfusion defect(24.4{+-}5.4%), which increased inferiorly. SI of normal myocardium and perfusion defect decreased inferiorly; their difference indicated stenosis-induced perfusion loss according to section location. Volumetric SI of normal myocardium and perfusion defect were 3.42{+-}0.52 and 2.16{+-}0.45, respectively(p<0.05). Gd-DTPA enhanced MRI displayed first-pass perfusion abnormality of coronary artery stenosis as perfusion defect with distinct low SI; this enabled the measurement of its volume and SI changes according to section location, and thus indicated the value of first-pass MR imaging in the diagnosis of myocardial ischemia.

  5. First-pass perfusion disturbance of coronary artery stenosis: an experimental study using MR imaging with Gd-DTPA enhancement

    International Nuclear Information System (INIS)

    Chung, Kyung Il; Lee, Young Ju; Lim, Tae Hwan

    1997-01-01

    In order to determine the value of first-pass MR imaging in the diagnosis of myocardial ischemia, first-pass perfusion abnormality of coronary artery stenosis was observed in MRI after gadopentate dimeglumine(GD-DTPA) enhancement. The left anterior descending(LAD) coronary arteries of six dogs were subjected to approximately 70% stenosis confirmed by coronary angiography. Half an hour after adenosine and 99m Tc-sestamibi infusion, Gd-DTPA(0.2mmol/kg) and methylene blue were administered and termination was induced with potassium chloride. SE T1-weighted and single-photon emission computed tomography(SPECT) images were subsequently obtained and the findings of perfusion defect compared with specimen stain. Three dimensionally reconstructed MR images were used to measure signal intensity(SI) of normal myocardium and perfusion defect from their sectional and total volume. Five of six dogs with LAD artey stenosis ranging from 66% to 73% displayed perfusion defect on MRI, SPECT, and specimen stain, but the remaining dog with stenosis of 58% showed no such defect. MRI showed the perfusion defect as distinct low SI, enabling the measurement of percentage perfusion defect(24.4±5.4%), which increased inferiorly. SI of normal myocardium and perfusion defect decreased inferiorly; their difference indicated stenosis-induced perfusion loss according to section location. Volumetric SI of normal myocardium and perfusion defect were 3.42±0.52 and 2.16±0.45, respectively(p<0.05). Gd-DTPA enhanced MRI displayed first-pass perfusion abnormality of coronary artery stenosis as perfusion defect with distinct low SI; this enabled the measurement of its volume and SI changes according to section location, and thus indicated the value of first-pass MR imaging in the diagnosis of myocardial ischemia

  6. A relative quantitative assessment of myocardial perfusion by first-pass technique: animal study

    Science.gov (United States)

    Chen, Jun; Zhang, Zhang; Yu, Xuefang; Zhou, Kenneth J.

    2015-03-01

    The purpose of this study is to quantitatively assess the myocardial perfusion by first-pass technique in swine model. Numerous techniques based on the analysis of Computed Tomography (CT) Hounsfield Unit (HU) density have emerged. Although these methods proposed to be able to assess haemodynamically significant coronary artery stenosis, their limitations are noticed. There are still needs to develop some new techniques. Experiments were performed upon five (5) closed-chest swine. Balloon catheters were placed into the coronary artery to simulate different degrees of luminal stenosis. Myocardial Blood Flow (MBF) was measured using color microsphere technique. Fractional Flow Reserve (FFR) was measured using pressure wire. CT examinations were performed twice during First-pass phase under adenosine-stress condition. CT HU Density (HUDCT) and CT HU Density Ratio (HUDRCT) were calculated using the acquired CT images. Our study presents that HUDRCT shows a good (y=0.07245+0.09963x, r2=0.898) correlation with MBF and FFR. In receiver operating characteristic (ROC) curve analyses, HUDRCT provides excellent diagnostic performance for the detection of significant ischemia during adenosine-stress as defined by FFR indicated by the value of Area Under the Curve (AUC) of 0.927. HUDRCT has the potential to be developed as a useful indicator of quantitative assessment of myocardial perfusion.

  7. Comprehensive Assessment of Coronary Artery Disease by Using First-Pass Analysis Dynamic CT Perfusion: Validation in a Swine Model.

    Science.gov (United States)

    Hubbard, Logan; Lipinski, Jerry; Ziemer, Benjamin; Malkasian, Shant; Sadeghi, Bahman; Javan, Hanna; Groves, Elliott M; Dertli, Brian; Molloi, Sabee

    2018-01-01

    Purpose To retrospectively validate a first-pass analysis (FPA) technique that combines computed tomographic (CT) angiography and dynamic CT perfusion measurement into one low-dose examination. Materials and Methods The study was approved by the animal care committee. The FPA technique was retrospectively validated in six swine (mean weight, 37.3 kg ± 7.5 [standard deviation]) between April 2015 and October 2016. Four to five intermediate-severity stenoses were generated in the left anterior descending artery (LAD), and 20 contrast material-enhanced volume scans were acquired per stenosis. All volume scans were used for maximum slope model (MSM) perfusion measurement, but only two volume scans were used for FPA perfusion measurement. Perfusion measurements in the LAD, left circumflex artery (LCx), right coronary artery, and all three coronary arteries combined were compared with microsphere perfusion measurements by using regression, root-mean-square error, root-mean-square deviation, Lin concordance correlation, and diagnostic outcomes analysis. The CT dose index and size-specific dose estimate per two-volume FPA perfusion measurement were also determined. Results FPA and MSM perfusion measurements (P FPA and P MSM ) in all three coronary arteries combined were related to reference standard microsphere perfusion measurements (P MICRO ), as follows: P FPA_COMBINED = 1.02 P MICRO_COMBINED + 0.11 (r = 0.96) and P MSM_COMBINED = 0.28 P MICRO_COMBINED + 0.23 (r = 0.89). The CT dose index and size-specific dose estimate per two-volume FPA perfusion measurement were 10.8 and 17.8 mGy, respectively. Conclusion The FPA technique was retrospectively validated in a swine model and has the potential to be used for accurate, low-dose vessel-specific morphologic and physiologic assessment of coronary artery disease. © RSNA, 2017.

  8. Prevalence of first-pass myocardial perfusion defects detected by contrast-enhanced dual-source CT in patients with non-ST segment elevation acute coronary syndromes

    Energy Technology Data Exchange (ETDEWEB)

    Schepis, Tiziano; Achenbach, Stephan; Marwan, Mohamed; Muschiol, Gerd; Ropers, Dieter; Daniel, Werner G.; Pflederer, Tobias [University of Erlangen, Department of Internal Medicine 2 (Cardiology), Erlangen (Germany)

    2010-07-15

    To investigate the prevalence and diagnostic value of first-pass myocardial perfusion defects (PD) visualised by contrast-enhanced multidetector computed tomography (MDCT) in patients admitted for a first acute coronary syndrome (ACS). Thirty-eight patients with non-ST segment elevation myocardial infarction (NSTEMI) or unstable angina (UA) and scheduled for percutaneous coronary intervention underwent dual-source CT immediately before catheterisation. CT images were analysed for the presence of any PD by using a 17-segment model. Results were compared with peak cardiac troponin-I (cTnI) and angiography findings. PD were seen in 21 of the 24 patients with NSTEMI (median peak cTnI level 7.07 ng/mL; range 0.72-37.07 ng/mL) and in 2 of 14 patients with UA. PD corresponded with the territory of the infarct-related artery in 20 out of 22 patients. In a patient-based analysis, sensitivity, specificity, negative and positive predictive values of any PD for predicting NSTEMI were 88%, 86%, 80% and 91%. Per culprit artery, the respective values were 86%, 75%, 80% and 83%. In patients with non-ST segment elevation ACS, first-pass myocardial PD in contrast-enhanced MDCT correlate closely with the presence of myocardial necrosis, as determined by increases in cTnI levels. (orig.)

  9. Congenital coronary-pulmonary artery fistula originating from right and left coronary artery

    Directory of Open Access Journals (Sweden)

    Ali Kemal Gür

    2013-12-01

    Full Text Available Coronary artery fistula (CAF is a rare congenital anomalywith an incidence of 1 in 50 000 live births. The fistula wasobserved at the right coronary artery in 53%, the left coronaryartery in 42% and both coronary artery in 5% of thecases. Echocardiography examination in a 46 year-oldwoman with the symptoms of chest pain, palpitation anddyspnea revealed a severe mitral valve insufficiency anda moderate to severe tricuspid valve insufficiency. A CAForiginating from the proximal part of the left anterior descendingartery (LAD and another fistula originating fromosteal part of the right coronary artery (RCA were detectedby coronary angiography. Both fistulas were draininginto the main pulmonary artery. The coronary artery fistulaclosed under cardiopulmonary by-pass. Mitral insufficiencyoriginated from the posterior leaflet was diagnosedintra-operative exploration, and thereafter it was repairedwith mitral annuloplasty including a quadrangular resectionand use of a 32 No St Jude mitral ring. Tricuspid valvewas repaired with Calangos Ring annuloplasty. Followingsix day hospital stay, the woman was discharged free ofany symptom.Key words: Dyspnea, double arteriovenous fistula, mitral and tricuspid insufficiency

  10. Clinical assessment of first pass radionuclide ventriculography after dipyridamole infusion in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Kanaya, Tohru; Tono-oka, Ichiro; Satoh, Satoshi; Yamaguchi, Yoshiko; Hoshi, Hikaru; Ikeda, Kozue; Tsuiki, Kai; Yasui, Shoji; Komatani, Akio

    1986-01-01

    First pass radionuclide ventriculography (RNV) was performed after dipyridamole (D) infusion in 33 patients with coronary artery disease (CAD) and 15 normal volunteers. RNV findings after D infusion were compared with those of conventional exercise RNV and body surface ECG mapping (MAP). For patients with multiple vessel disease, left ventricular ejection fraction (LVEF) was significantly lower after D infusion than at rest. Wall motion abnormality (WMA) sites induced by D infusion were well coincident with those induced by exercise. Pressure rate product at exercise was significantly higher than that after D infusion, suggesting the different mechanism of the occurrence of WMA after D infusion and at exercise. The incidence of ischemic reaction tended to be higher after D infusion than at exercise in 25 patients with CAD. There was negative correlation between ST depression on MAP after D infusion and LVEF on RNV after D infusion. This RNV after D infusion can be used as a supplement tool to conventional exercise RNV in the evaluation of the degree of coronary artery lesions and preserved left ventricular function. (Namekawa, K.)

  11. Improvements in Low-cost Ultrasonic Measurements of Blood Flow in "by-passes" Using Narrow & Broad Band Transit-time Procedures

    Science.gov (United States)

    Ramos, A.; Calas, H.; Diez, L.; Moreno, E.; Prohías, J.; Villar, A.; Carrillo, E.; Jiménez, A.; Pereira, W. C. A.; Von Krüger, M. A.

    The cardio-pathology by ischemia is an important cause of death, but the re-vascularization of coronary arteries (by-pass operation) is an useful solution to reduce associated morbidity improving quality of life in patients. During these surgeries, the flow in coronary vessels must be measured, using non-invasive ultrasonic methods, known as transit time flow measurements (TTFM), which are the most accurate option nowadays. TTFM is a common intra-operative tool, in conjunction with classic Doppler velocimetry, to check the quality of these surgery processes for implanting grafts in parallel with the coronary arteries. This work shows important improvements achieved in flow-metering, obtained in our research laboratories (CSIC, ICIMAF, COPPE) and tested under real surgical conditions in Cardiocentro-HHA, for both narrowband NB and broadband BB regimes, by applying results of a CYTED multinational project (Ultrasonic & computational systems for cardiovascular diagnostics). mathematical models and phantoms were created to evaluate accurately flow measurements, in laboratory conditions, before our new electronic designs and low-cost implementations, improving previous ttfm systems, which include analogic detection, acquisition & post-processing, and a portable PC. Both regimes (NB and BB), with complementary performances for different conditions, were considered. Finally, specific software was developed to offer facilities to surgeons in their interventions.

  12. Prediction of coronary artery disease in patients undergoing operations for mitral valve degeneration

    Science.gov (United States)

    Lin, S. S.; Lauer, M. S.; Asher, C. R.; Cosgrove, D. M.; Blackstone, E.; Thomas, J. D.; Garcia, M. J.

    2001-01-01

    OBJECTIVES: We sought to develop and validate a model that estimates the risk of obstructive coronary artery disease in patients undergoing operations for mitral valve degeneration and to demonstrate its potential clinical utility. METHODS: A total of 722 patients (67% men; age, 61 +/- 12 years) without a history of myocardial infarction, ischemic electrocardiographic changes, or angina who underwent routine coronary angiography before mitral valve prolapse operations between 1989 and 1996 were analyzed. A bootstrap-validated logistic regression model on the basis of clinical risk factors was developed to identify low-risk (coronary atherosclerosis was defined as 50% or more luminal narrowing in one or more major epicardial vessels, as determined by means of coronary angiography. RESULTS: One hundred thirty-nine (19%) patients had obstructive coronary atherosclerosis. Independent predictors of coronary artery disease include age, male sex, hypertension, diabetes mellitus,and hyperlipidemia. Two hundred twenty patients were designated as low risk according to the logistic model. Of these patients, only 3 (1.3%) had single-vessel disease, and none had multivessel disease. The model showed good discrimination, with an area under the receiver-operating characteristic curve of 0.84. Cost analysis indicated that application of this model could safely eliminate 30% of coronary angiograms, corresponding to cost savings of $430,000 per 1000 patients without missing any case of high-risk coronary artery disease. CONCLUSION: A model with standard clinical predictors can reliably estimate the prevalence of obstructive coronary atherosclerosis in patients undergoing mitral valve prolapse operations. This model can identify low-risk patients in whom routine preoperative angiography may be safely avoided.

  13. COMPLEX CORONARY PATTERN AFFECTING THE SURGICAL OUTCOME OF ARTERIAL SWITCH OPERATION

    Directory of Open Access Journals (Sweden)

    Amit

    2015-12-01

    Full Text Available BACKGROUND Arterial switch operation (ASO has become the procedure of choice for the transposition of great arteries as well as for Taussig-Bing anomaly. Relocation of coronary arteries remains a technical problem in anatomic correction of the transposed great arteries. The present prospective study is designed to analyse the effect of coronary artery pattern on surgical outcome of arterial switch operation. METHOD From August 2014 to November 2015, total 60 patients underwent ASO. The patients are divided in three groups. Group-A 21 patients with d-TGA with intact ventricle septum (d-TGA intact IVS, in Group-B 33 patients d-TGA with ventricular septal defect (d-TGA, VSD, and in Group C 6 Taussig Bing anomaly. The coronary pattern and outcome is analyzed. RESULTS The overall mortality related to coronary pattern was 5%. The 2 patients died due to Intramural coronary artery leading to post-operative ventricular dysfunction, another patient with single retro pulmonary coronary artery died secondary to low coronary implant leading to kinking in coronary artery and myocardial dysfunction. On 12 monthly follow up, one of the Patients in group A had right pulmonary artery stenosis with gradient of 30 mm of Hg. Another patient in group B had supravalvular gradient of 20 mm of Hg. CONCLUSION The ASO for TGA and Taussig-Bing anomaly has low early and late mortality. However, the mortality is still seen in the patients with Intramural coronary artery and in the patient with single coronary artery with retro pulmonary course.

  14. Prediction of coronary artery disease in patients undergoing operations for mitral valve degeneration

    Science.gov (United States)

    Lin, S. S.; Lauer, M. S.; Asher, C. R.; Cosgrove, D. M.; Blackstone, E.; Thomas, J. D.; Garcia, M. J.

    2001-01-01

    OBJECTIVES: We sought to develop and validate a model that estimates the risk of obstructive coronary artery disease in patients undergoing operations for mitral valve degeneration and to demonstrate its potential clinical utility. METHODS: A total of 722 patients (67% men; age, 61 +/- 12 years) without a history of myocardial infarction, ischemic electrocardiographic changes, or angina who underwent routine coronary angiography before mitral valve prolapse operations between 1989 and 1996 were analyzed. A bootstrap-validated logistic regression model on the basis of clinical risk factors was developed to identify low-risk (< or =5%) patients. Obstructive coronary atherosclerosis was defined as 50% or more luminal narrowing in one or more major epicardial vessels, as determined by means of coronary angiography. RESULTS: One hundred thirty-nine (19%) patients had obstructive coronary atherosclerosis. Independent predictors of coronary artery disease include age, male sex, hypertension, diabetes mellitus,and hyperlipidemia. Two hundred twenty patients were designated as low risk according to the logistic model. Of these patients, only 3 (1.3%) had single-vessel disease, and none had multivessel disease. The model showed good discrimination, with an area under the receiver-operating characteristic curve of 0.84. Cost analysis indicated that application of this model could safely eliminate 30% of coronary angiograms, corresponding to cost savings of $430,000 per 1000 patients without missing any case of high-risk coronary artery disease. CONCLUSION: A model with standard clinical predictors can reliably estimate the prevalence of obstructive coronary atherosclerosis in patients undergoing mitral valve prolapse operations. This model can identify low-risk patients in whom routine preoperative angiography may be safely avoided.

  15. Surgery of abdominal aortic aneurysm associated with coronary artery disease. Simultaneous or two staged operation

    International Nuclear Information System (INIS)

    Tanaka, Hiroyuki; Narisawa, Takashi; Mori, Takanobu; Masuda, Mikio; Kishi, Daijirou; Suzuki, Takashi; Takaba, Toshihiro

    2003-01-01

    Coronary artery disease (CAD) was evaluated by noninvasive examination in abdominal aortic aneurysm (AAA) patients. A simultaneous operation or a 2-staged operation was performed depending on the seriousness of the condition when both diseases were combined. A total of 36 patients underwent elective repair of AAA between 1996 and 2001. Coronary angiography (CAG) was performed only in patients with suspected CAD by dipyridamole myocardial scintigraphy. Significant CAD was found in 8 patients. Simultaneous operation was performed in 4 patients, and off-pump coronary artery bypass grafting (OPCAB) was performed in all cases of simultaneous operation. In 4 patients receiving 2-staged operations, 1 standard coronary artery bypass grafting (CABG), 1 OPCAB and 2 percutaneous transluminal coronary angioplasties (PTCA) were performed prior to AAA surgery. Twenty-eight patients underwent only AAA operation. Though there were no incidents of perioperative myocardial infarction or cardiac related deaths in this group, 2 patients died due to other causes (hemorrhage and duodenal perforation). In the 8 patients associated with CAD, 1 patient died of myonephrotic metabolic syndrome (MNMS) after simultaneous operation. The other 7 patients revived their social function soon of the discharge. Dipyridamole cardiac scintigraphy was considered to be an effective examination for evaluation of CAD in AAA patients. There was no need to perform CAG in all AAA patients. The policy of choosing simultaneous operation or 2-staged operation according to the seriousness of the 2 diseases seemed to be appropriate. (author)

  16. 78 FR 18479 - Drawbridge Operation Regulations; Pass Manchac, LA

    Science.gov (United States)

    2013-03-27

    ... governing the operation of the Canadian National (CN) Railroad automated bascule span drawbridge across Pass....gov . Type the docket number in the ``SEARCH'' box and click ``SEARCH.'' Click on Open Docket Folder... Operations, telephone 202-366-9826. SUPPLEMENTARY INFORMATION: The CN Railroad has requested a temporary...

  17. Integral diagnosis of coronary atherosclerosis by coronary multidetector computed tomography and by invasive coronary angiography

    International Nuclear Information System (INIS)

    Llerena Rojas, Luis Roberto; Llerena Rojas, Lorenzo D; Mendoza Rodriguez, Vladimir

    2013-01-01

    Coronary angiography by multidetector computed tomography (CMDCT) visualizes the wall and lumen of coronary arteries. Invasive coronary angiography (INVCA) only visualizes the arterial lumen but with better resolution

  18. Collector Efficiency in Downward-Type Double-Pass Solar Air Heaters with Attached Fins and Operated by External Recycle

    Directory of Open Access Journals (Sweden)

    Chii-Dong Ho

    2012-07-01

    Full Text Available The collector efficiency in a downward-type double-pass external-recycle solar air heater with fins attached on the absorbing plate has been investigated theoretically. Considerable improvement in collector efficiency is obtainable if the collector is equipped with fins and the operation is carried out with an external recycle. Due to the recycling, the desirable effect of increasing the heat transfer coefficient compensates for the undesirable effect of decreasing the driving force (temperature difference of heat transfer, while the attached fins provide an enlarged heat transfer area. The order of performances in the devices of same size is: double pass with recycle and fins > double pass with recycle but without fins > single pass without recycle and fins.

  19. Cell saver for on-pump coronary operations reduces systemic inflammatory markers: a randomized trial

    DEFF Research Database (Denmark)

    Damgaard, Sune; Nielsen, Claus Henrik; Andersen, Lars Willy

    2010-01-01

    This study investigated whether intraoperative use of a cell saver reduces the systemic inflammatory response after coronary operations using cardiopulmonary bypass (CPB).......This study investigated whether intraoperative use of a cell saver reduces the systemic inflammatory response after coronary operations using cardiopulmonary bypass (CPB)....

  20. [Psychoprophylaxis in patients after coronary artery bypass graft operations].

    Science.gov (United States)

    Rymaszewska, Joanna; Chładzińska-Kiejna, Sylwia; Górna, Renata; Kustrzycki, Wojciech

    2004-05-01

    The paper presented problems of quality of life and psychosocial functioning of patients following coronary artery bypass grafting operations. Possibilities of psychoprophylactic effects towards these patients and its efficacy were described.

  1. Operator radiation exposure during right or left transradial coronary angiography: A phantom study

    International Nuclear Information System (INIS)

    Sciahbasi, Alessandro; Rigattieri, Stefano; Sarandrea, Alessandro; Cera, Maria; Di Russo, Cristian; Fedele, Silvio; Romano, Silvio; Pugliese, Francesco Rocco; Penco, Maria

    2015-01-01

    Background: Previous studies showed a possible lower radiation dose absorbed by operators comparing LRA and RRA for percutaneous coronary procedures. The reasons of this lower radiation dose are not well known. The aim of this study was to evaluate the radiation dose absorbed by operators comparing left with right radial access (LRA and RRA respectively) during a simulated diagnostic coronary angiography using a phantom. Methods: A coronary angiography examination was simulated on a phantom by 5 operators using eight projections with 5 seconds fluoroscopy each. Each operator was equipped with 4 electronic dosimeters placed at thorax, at left wrist, at left head and at hip level. Radiation doses were expressed in picosievert and normalized by dose area product. Results: LRA compared to RRA was associated with a significant lower operator dose at wrist (36 pSv/cGYcm"2 [IQR 18–59 pSv/cGYcm"2] and 48 pSv/cGYcm"2 [IQR 22–148 pSv/cGYcm"2] respectively, p = 0.01) and thorax (3 pSv/cGYcm"2 [IQR 2–5 pSv/cGYcm"2] and 10 pSv/cGYcm"2 [6–23 pSv/cGYcm"2] respectively, p < 0.001) but with a significant higher radiation dose at hip level (102 pSv/cGYcm"2 [IQR 44–199 pSv/cGYcm"2] and 67 pSv/cGYcm"2 [IQR 39–132 pSv/cGYcm"2] respectively, p = 0.02). Conversely the radiation dose at left side of the head did not show significant differences between the two approaches. Conclusions: In this phantom study simulating a diagnostic coronarography the use of LRA compared to RRA was associated with a significant lower radiation dose at wrist and thorax but with an increased dose at hip level. Summary: To evaluate the radiation dose absorbed by operators comparing left with right radial access (LRA and RRA respectively) we simulated a diagnostic coronary angiography using a dedicated phantom. Operators were equipped with dedicated electronic dosimeters at wrist, hip, head and thorax level. LRA compared to RRA was associated with a significant lower operator dose at wrist and thorax

  2. 77 FR 31725 - Safety Zone; Belle Pass Dredge Operations, Belle Pass, Mile Marker 1.0 to Mile Marker (−0.2...

    Science.gov (United States)

    2012-05-30

    ... Environmental Health Risks and Safety Risks. This rule is not an economically significant rule and does not create an environmental risk to health or risk to safety that may disproportionately affect children. 11...-AA00 Safety Zone; Belle Pass Dredge Operations, Belle Pass, Mile Marker 1.0 to Mile Marker (-0.2), Port...

  3. Effects of Data Passing Semantics and Operating System Structure on Network I/O Performance

    National Research Council Canada - National Science Library

    Brustoloni, Jose

    1997-01-01

    .... Researchers have often proposed changing the semantics of I/O data passing, so as to make copying unnecessary, or the structure of the operating system, so as to reduce or eliminate data and control passing...

  4. Iterative deblending of simultaneous-source data using a coherency-pass shaping operator

    Science.gov (United States)

    Zu, Shaohuan; Zhou, Hui; Mao, Weijian; Zhang, Dong; Li, Chao; Pan, Xiao; Chen, Yangkang

    2017-10-01

    Simultaneous-source acquisition helps greatly boost an economic saving, while it brings an unprecedented challenge of removing the crosstalk interference in the recorded seismic data. In this paper, we propose a novel iterative method to separate the simultaneous source data based on a coherency-pass shaping operator. The coherency-pass filter is used to constrain the model, that is, the unblended data to be estimated, in the shaping regularization framework. In the simultaneous source survey, the incoherent interference from adjacent shots greatly increases the rank of the frequency domain Hankel matrix that is formed from the blended record. Thus, the method based on rank reduction is capable of separating the blended record to some extent. However, the shortcoming is that it may cause residual noise when there is strong blending interference. We propose to cascade the rank reduction and thresholding operators to deal with this issue. In the initial iterations, we adopt a small rank to severely separate the blended interference and a large thresholding value as strong constraints to remove the residual noise in the time domain. In the later iterations, since more and more events have been recovered, we weaken the constraint by increasing the rank and shrinking the threshold to recover weak events and to guarantee the convergence. In this way, the combined rank reduction and thresholding strategy acts as a coherency-pass filter, which only passes the coherent high-amplitude component after rank reduction instead of passing both signal and noise in traditional rank reduction based approaches. Two synthetic examples are tested to demonstrate the performance of the proposed method. In addition, the application on two field data sets (common receiver gathers and stacked profiles) further validate the effectiveness of the proposed method.

  5. Recurrent post-partum coronary artery dissection

    Directory of Open Access Journals (Sweden)

    Resnic Frederic S

    2010-10-01

    Full Text Available Abstract Coronary artery dissection is a rare but well-described cause for myocardial infarction during the post-partum period. Dissection of multiple coronary arteries is even less frequent. Here we present a case of recurrent post-partum coronary artery dissections. This unusual presentation poses unique problems for management. A 35 year-old female, gravida 3 para 2, presented with myocardial infarction 9 weeks and 3 days post-partum. Cardiac catheterization demonstrated left anterior descending (LAD dissection but an otherwise normal coronary anatomy. The lesion was treated with four everolimus eluting stents. Initially the patient made an unremarkable recovery until ventricular fibrillation arrest occurred on the following day. Unsynchronized cardioversion restored a normal sinus rhythm and repeat catheterization revealed new right coronary artery (RCA dissection. A wire was passed distally, but it was unclear whether this was through the true or false lumen and no stents could be placed. However, improvement of distal RCA perfusion was noted on angiogram. Despite failure of interventional therapy the patient was therefore treated conservatively. Early operation after myocardial infarction has a significantly elevated risk of mortality and the initial dissection had occurred within 24 hours. This strategy proved successful as follow-up transthoracic echocardiography after four months demonstrated a preserved left ventricular ejection fraction of 55-60% without regional wall motion abnormalities. The patient remained asymptomatic from a cardiac point of view.

  6. Evaluation of contrast wash-in and peak enhancement in adenosine first pass perfusion CMR in patients post bypass surgery

    Directory of Open Access Journals (Sweden)

    Schnackenburg Bernhard

    2010-05-01

    Full Text Available Abstract Background Adenosine first pass perfusion cardiovascular magnetic resonance (CMR yields excellent results for the detection of significant coronary artery disease (CAD. In patients with coronary artery bypass grafts (CABG the kinetics of a contrast bolus may by altered only due to different distances through the bypass grafts compared to native vessels, thereby possibly imitating a perfusion defect. The aim of the study was to evaluate semiquantitative perfusion parameters in order to assess possible differences in epicardial contrast kinetics in areas supplied by native coronaries and CABG, both without significant stenosis. Methods Twenty patients with invasive exclusion of significant CAD (control group and 38 patients with CABG without angiographically significant (≥50% stenosis in unbypassed coronaries or grafts were retrospectively included in the study. They underwent adenosine first pass (0.05 mmol/kg Gd-DTPA perfusion (3 short axis views/heart beat and late gadolinium enhancement (LGE imaging 1 day before invasive coronary angiography. Areas perfused by native coronaries and/or the different bypasses were identified in X-ray angiography using the 16 segment model. In each of these areas upslope and maximal signal intensity (SImax relative to the left ventricular parameters, time to 50% maximal signal intensity (TSI50%max and time to maximal signal intensity (TSImax were calculated. Results In areas perfused by coronary arteries with bypasses compared to native coronaries relative upslope and relative SImax did not show a significant difference. TSI50%max and TSImax in native coronaries and bypasses were 7.2s ± 1.9s vs. 7.5s ± 1.9s (p max resulted in a significant (p Conclusion Adenosine perfusion CMR in patients post CABG may be associated with a short delay in contrast arrival. However, once the contrast is in the myocardium there is similar wash-in kinetics and peak enhancement. Therefore, since the delay is only short

  7. Target vessel detection by epicardial ultrasound in off-pump coronary bypass surgery.

    Science.gov (United States)

    Hayakawa, Masato; Asai, Tohru; Kinoshita, Takeshi; Suzuki, Tomoaki; Shiraishi, Shoichiro

    2013-01-01

    The detection of embedded coronary arteries is difficult especially in off-pump coronary bypass surgery. From June 2010, we introduced high-frequency epicardial ultrasound (ECUS) to assess and evaluate embedded arteries during off-pump coronary bypass surgery. Between June 2010 and June 2011, a total of 89 consecutive patients underwent isolated coronary bypass surgery at our institution. The patients consisted of 72 men and 17 women with a mean age of 67.9 years. We routinely use the VeriQC system (MediStim, Oslo, Norway) to detect the target vessels in the operation. The patients were assigned to one of two groups, depending on whether ECUS was used in the operation (n = 10, ECUS group) or not (n = 79, non-ECUS group). We analyzed the impact of introducing the ECUS in terms of operative outcome. All patients underwent revascularization using the off-pump technique without emergent conversion to cardiopulmonary bypass during surgery. The total number of distal anastomoses was 299, and 12 target vessels could not be identified either visually or on palpation. Thus, the frequency of the embedded coronary arteries was 4.01% (12/299 cases). The preoperative profiles of the two groups were not significantly different. Operation time was significantly longer in the ECUS group (P = 0.02). There were no significant differences in postoperative outcome between the two groups. In the present study, in which the target coronary arteries could not be detected either visually or on palpation in 12 (4.01%) of 299 cases, the use of high-frequency ECUS allowed all patients to undergo off-pump coronary bypass surgery without conversion to cardiopulmonary bypass during the operation. High-frequency ECUS is therefore useful in off-pump coronary bypass surgery.

  8. YKL-40 a new biomarker in patients with acute coronary syndrome or stable coronary artery disease

    DEFF Research Database (Denmark)

    Wang, Y.Z.; Ripa, R.S.; Johansen, J.S.

    2008-01-01

    Background. YKL-40 is involved in remodelling and angiogenesis in non-cardiac inflammatory diseases. Aim was to quantitate plasma YKL-40 in patients with ST-elevation myocardial infarction (STEMI) or stable chronic coronary artery disease (CAD), and YKL-40 gene activation in human myocardium....... Methods and results. We included 73 patients: I) 20 patients with STEMI; II) 28 patients with stable CAD; III) 15 CAD patients referred for coronary by-pass surgery. YKL-40 mRNA expression was measured in myocardium subtended by stenotic or occluded arteries and areas with no apparent disease; and IV) 10...

  9. Non-obstructive coronary artery disease assessed by coronary computed tomography angiography

    DEFF Research Database (Denmark)

    Nielsen, L.; Bøtker, H. E.; Sorensen, H.

    2015-01-01

    Introduction: Coronary CT angiography (CTA) detects non-obstructive coronary artery disease (CAD) that may not be recognized by functional testing, but the prognostic impact is not well understood. This study aimed to compare the risk of myocardial infarction (MI) and all-cause mortality...... in patients without or with non-obstructive and obstructive CAD assessed by coronary CTA. Methods: Consecutive patients without known coronary artery disease (CAD) and with chest pain who underwent coronary CTA (>64-detector row) between January 2007 and December 2012 in the 10 centers participating...... in the Western Denmark Cardiac Computed Tomography Registry were included. The endpoints were 3-year MI or all-cause mortality. The coronary CTA result was defined as normal (0% luminal stenosis), non-obstructive CAD (1%-49% luminal stenosis) or obstructive CAD (>50% luminal stenosis; 1-vessel, 2-vessel, or 3...

  10. Flexibility and trackability of laser cut coronary stent systems.

    Science.gov (United States)

    Szabadíts, Péter; Puskás, Zsolt; Dobránszky, János

    2009-01-01

    Coronary stents are the most important supports in present day cardiology. Flexibility and trackability are two basic features of stents. In this paper, four different balloon-expandable coronary stent systems were investigated mechanically in order to compare their suitability. The coronary stent systems were assessed by measurements of stent flexibility as well as by comparison of forces during simulated stenting in a self-investigated coronary vessel model. The stents were cut by laser from a single tube of 316L stainless steel or L-605 (CoCr) cobalt chromium alloy. The one-and four-point bending tests were carried out to evaluate the stent flexibility E x I (Nmm(2)), under displacement control in crimped and expanded configurations. The flexibility of stents would be rather dependent on the design than on raw material. In general a more flexible stent needs lower tracking force during the implantation. The L-605 raw material stents need lower track force to pass through in the vessel model than the 316L raw material stents. The sort and long stents passed through the curved vessel model in different ways. The long stents nestled to the vessel wall at the outer arc and bent, while the short stents did not bend in the curve, only the delivery systems bent.

  11. The cristal (right superior septal) coronary artery and its relationship to anomalous left coronary origin

    International Nuclear Information System (INIS)

    Partridge, J.B.; Ridley, L.J.

    2011-01-01

    The cristal artery is an occasional finding, being visible in around 3% of coronary angiograms, arising from the proximal right coronary artery (RCA) and passing downwards and forwards through the muscle of the crista superventricularis. It supplies a variable volume of the superior interventricular septum, and can contribute to collateralization of the other septal vessels. When part or all of the left coronary artery (LCA) arises anomalously from the right coronary sinus, its passage to the left may be in the same pathway as a cristal artery, bearing a tell-tale septal vessel arising from its proximal segment. This helps to differentiate it from one that has a higher pathway, running between the great vessels, and which may have a greater correlation with sudden cardiac death.

  12. Phase changes caused by hyperventilation stress in spastic angina pectoris analyzed by first-pass radionuclide ventriculography

    International Nuclear Information System (INIS)

    Wu, Jin; Takeda, Tohoru; Ajisaka, Ryuichi; Masuoka, Takeshi; Watanabe, Sigeyuki; Sato, Motohiro; Itai, Yuji; Toyama, Hinako; Ishikawa, Nobuyoshi

    1999-01-01

    To understand the effect of hyperventilation (HV) stress in patients with spastic angina, left ventricular (LV) contraction was analyzed by quantitative phase analysis. The study was performed on 36 patients with spastic angina pectoris, including vasospastic angina pectoris (VspAP: 16 patients) and variant angina pectoris (VAP: 20 patients). First-pass radionuclide ventriculography (first-pass RNV) was performed at rest and after HV stress, and standard deviation of the LV phase distribution (SD) was analyzed. The SD was lower in patients with VspAP than in VAP(12.8±1.4 degrees vs. 14.6±2.2 degrees, p<0.005) at rest. After HV stress, the SD (HVSD) tended to increase in VspAP patients (62.5%), whereas the SD decreased in VAP patients (70%). Due to HV stress, the percentage change in SD (%SD) in VspAP patients was 8.9±23.7% whereas that in VAP patients was -9.1±17.3% (p<0.01). Moreover, phase histograms were divided into HVSD increase and HVSD decrease groups. The HVSD increase group had a decrease of HVEF, but the HVSD decrease group tended to have more decreased HVEF than the HVSD increase group. These results indicate that spastic angina pectoris patients show various responses to HV stress. The HVSD increase group might have additional myocardial ischemia due to regional coronary spasm. In contrast, in the HVSD decrease group severe LV dysfunction or diffuse wall motion abnormality might have been generated, and this caused a reduction in the SD value. Phase analysis would therefore add new information regarding electrocardiographically silent myocardial ischemia due to coronary spasm, and HV stress might increase sensitivity for the detection of abnormalities in quantitative phase analysis, especially in VspAP patients. (author)

  13. Phase changes caused by hyperventilation stress in spastic angina pectoris analyzed by first-pass radionuclide ventriculography

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Jin; Takeda, Tohoru; Ajisaka, Ryuichi; Masuoka, Takeshi; Watanabe, Sigeyuki; Sato, Motohiro; Itai, Yuji [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine; Toyama, Hinako; Ishikawa, Nobuyoshi

    1999-02-01

    To understand the effect of hyperventilation (HV) stress in patients with spastic angina, left ventricular (LV) contraction was analyzed by quantitative phase analysis. The study was performed on 36 patients with spastic angina pectoris, including vasospastic angina pectoris (VspAP: 16 patients) and variant angina pectoris (VAP: 20 patients). First-pass radionuclide ventriculography (first-pass RNV) was performed at rest and after HV stress, and standard deviation of the LV phase distribution (SD) was analyzed. The SD was lower in patients with VspAP than in VAP(12.8{+-}1.4 degrees vs. 14.6{+-}2.2 degrees, p<0.005) at rest. After HV stress, the SD (HVSD) tended to increase in VspAP patients (62.5%), whereas the SD decreased in VAP patients (70%). Due to HV stress, the percentage change in SD (%SD) in VspAP patients was 8.9{+-}23.7% whereas that in VAP patients was -9.1{+-}17.3% (p<0.01). Moreover, phase histograms were divided into HVSD increase and HVSD decrease groups. The HVSD increase group had a decrease of HVEF, but the HVSD decrease group tended to have more decreased HVEF than the HVSD increase group. These results indicate that spastic angina pectoris patients show various responses to HV stress. The HVSD increase group might have additional myocardial ischemia due to regional coronary spasm. In contrast, in the HVSD decrease group severe LV dysfunction or diffuse wall motion abnormality might have been generated, and this caused a reduction in the SD value. Phase analysis would therefore add new information regarding electrocardiographically silent myocardial ischemia due to coronary spasm, and HV stress might increase sensitivity for the detection of abnormalities in quantitative phase analysis, especially in VspAP patients. (author)

  14. Identification of coronary artery anatomy on dual-source cardiac computed tomography before arterial switch operation in newborns and young infants. Comparison with transthoracic echocardiography

    International Nuclear Information System (INIS)

    Goo, Hyun Woo

    2018-01-01

    Considering inherent limitations of transthoracic echocardiography, the diagnostic accuracy of cardiac CT in identifying coronary artery anatomy before arterial switch operation needs to be investigated with recently improved coronary artery visibility using electrocardiogram (ECG)-synchronized dual-source CT. To compare diagnostic accuracy between cardiac CT using a dual-source scanner and transthoracic echocardiography in identifying coronary artery anatomy before arterial switch operation in newborns and young infants. The study included 101 infants (median age 4 days, range 0 days to 10 months; M:F=78:23) who underwent ECG-synchronized cardiac dual-source CT and transthoracic echocardiography before arterial switch operation between July 2011 and December 2016. We evaluated and classified coronary artery anatomy on cardiac CT and transthoracic echocardiography. With the surgical findings as the reference standard, we compared the diagnostic accuracy for identifying coronary artery anatomy between cardiac CT and transthoracic echocardiography. The most common coronary artery pattern was the usual pattern (left coronary artery from sinus 1 and right coronary artery from sinus 2; 64.4%, 65/101), followed by a single coronary artery from sinus 2 and a conal branch from sinus 1 (7.9%, 8/101), the inverted pattern (5.9%, 6/101), the right coronary artery and left anterior descending artery from sinus 1 and the left circumflex artery from sinus 2 (5.9%, 6/101), and others. In 96 infants with surgically proven coronary artery anatomy, the diagnostic accuracy of cardiac CT was significantly higher than that of transthoracic echocardiography (91.7%, 88/96 vs. 54.2%, 52/96; P<0.0001). Diagnostic accuracy of cardiac CT is significantly higher than that of echocardiography in identifying coronary artery anatomy before arterial switch operation in newborns and young infants. (orig.)

  15. Identification of coronary artery anatomy on dual-source cardiac computed tomography before arterial switch operation in newborns and young infants. Comparison with transthoracic echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology, Seoul (Korea, Republic of)

    2018-02-15

    Considering inherent limitations of transthoracic echocardiography, the diagnostic accuracy of cardiac CT in identifying coronary artery anatomy before arterial switch operation needs to be investigated with recently improved coronary artery visibility using electrocardiogram (ECG)-synchronized dual-source CT. To compare diagnostic accuracy between cardiac CT using a dual-source scanner and transthoracic echocardiography in identifying coronary artery anatomy before arterial switch operation in newborns and young infants. The study included 101 infants (median age 4 days, range 0 days to 10 months; M:F=78:23) who underwent ECG-synchronized cardiac dual-source CT and transthoracic echocardiography before arterial switch operation between July 2011 and December 2016. We evaluated and classified coronary artery anatomy on cardiac CT and transthoracic echocardiography. With the surgical findings as the reference standard, we compared the diagnostic accuracy for identifying coronary artery anatomy between cardiac CT and transthoracic echocardiography. The most common coronary artery pattern was the usual pattern (left coronary artery from sinus 1 and right coronary artery from sinus 2; 64.4%, 65/101), followed by a single coronary artery from sinus 2 and a conal branch from sinus 1 (7.9%, 8/101), the inverted pattern (5.9%, 6/101), the right coronary artery and left anterior descending artery from sinus 1 and the left circumflex artery from sinus 2 (5.9%, 6/101), and others. In 96 infants with surgically proven coronary artery anatomy, the diagnostic accuracy of cardiac CT was significantly higher than that of transthoracic echocardiography (91.7%, 88/96 vs. 54.2%, 52/96; P<0.0001). Diagnostic accuracy of cardiac CT is significantly higher than that of echocardiography in identifying coronary artery anatomy before arterial switch operation in newborns and young infants. (orig.)

  16. Progression of left main coronary artery disease 3 years after Bentall operation in a young female with Marfan syndrome.

    Science.gov (United States)

    Nishino, Tomohiro; Ehara, Natsuhiko; Kim, Kitae; Yamamuro, Atsushi; Kitai, Takeshi; Kobori, Atsushi; Kinoshita, Makoto; Kaji, Shuichiro; Tani, Tomoko; Okada, Yukikatsu; Furukawa, Yutaka

    2013-04-01

    A 39-year-old woman with Marfan syndrome presented to our hospital with chest oppression on effort. She underwent aortic root remodeling combined with aortic valve replacement 14 years ago and Bentall operation for enlargement of remaining native Valsalva sinus 3 years ago. A coronary computed tomography and a coronary angiography showed left main coronary artery stenosis, which was subsequently treated with percutaneous coronary intervention using a bare-metal stent. Follow-up coronary angiography performed 1 year after stenting revealed no restenosis.

  17. Coronary microembolization with normal epicardial coronary arteries and no visible infarcts on nitrobluetetrazolium chloride-stained specimens: Evaluation with cardiac magnetic resonance imaging in a swine model

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Hang; Yun, Hong; Zeng, Meng Su [Dept. of Radiology, Zhongshan Hospital, Fudan University and Shanghai Institute of Medical Imaging, Shanghai (China); Ma, Jian Ying; Chen, Zhang Wei; Chang, Shu Fu [Dept. of Cardiology, Zhongshan Hospital, Fudan University and Shanghai Institute of Cardiovascular Diseases, Shanghai (China)

    2016-02-15

    To assess magnetic resonance imaging (MRI) features of coronary microembolization in a swine model induced by small-sized microemboli, which may cause microinfarcts invisible to the naked eye. Eleven pigs underwent intracoronary injection of small-sized microspheres (42 µm) and catheter coronary angiography was obtained before and after microembolization. Cardiac MRI and measurement of cardiac troponin T (cTnT) were performed at baseline, 6 hours, and 1 week after microembolization. Postmortem evaluation was performed after completion of the imaging studies. Coronary angiography pre- and post-microembolization revealed normal epicardial coronary arteries. Systolic wall thickening of the microembolized regions decreased significantly from 42.6 ± 2.0% at baseline to 20.3 ± 2.3% at 6 hours and 31.5 ± 2.1% at 1 week after coronary microembolization (p < 0.001 for both). First-pass perfusion defect was visualized at 6 hours but the extent was largely decreased at 1 week. Delayed contrast enhancement MRI (DE-MRI) demonstrated hyperenhancement within the target area at 6 hours but not at 1 week. The microinfarcts on gross specimen stained with nitrobluetetrazolium chloride were invisible to the naked eye and only detectable microscopically. Increased cTnT was observed at 6 hours and 1 week after microembolization. Coronary microembolization induced by a certain load of small-sized microemboli may result in microinfarcts invisible to the naked eye with normal epicardial coronary arteries. MRI features of myocardial impairment secondary to such microembolization include the decline in left ventricular function and myocardial perfusion at cine and first-pass perfusion imaging, and transient hyperenhancement at DE-MRI.

  18. Pre-operative anxiety in patients undergoing coronary artery bypass graft surgery – A cross-sectional study

    Directory of Open Access Journals (Sweden)

    C. Ramesh

    Full Text Available Background: Coronary artery bypass graft surgery is an important treatment for the patients with coronary artery disease to reduce angina and enhance the quality of life. Anxiety is a usual reaction to a stressful situation and is existing in patients awaiting surgery. Objective: The objective of the study was to assess pre-operative anxiety in patients who were undergoing coronary artery bypass graft surgery. Methods: A cross-sectional study consisting of 140 patients undergoing coronary artery bypass graft surgery were included in the study using a convenience sampling technique in a tertiary care referral hospital. The data was collected using state-trait anxiety inventory. The data were entered into SPSS (version – 20.0 for windows and descriptive and inferential statistics were performed. Results: The study enrolled 140 (117 males and 23 females patients. Their mean age was 57.29 ± 8.14 (range 35–70 years. Most of the patients 118 (84% had preoperative anxiety before coronary artery bypass graft surgery. There was an association found between gender and anxiety with Pearson chi-square value of 11.57 (p < 0.001. Discussion: Patients undergoing coronary artery bypass graft surgery is experiencing the high level of pre-operative anxiety and females had higher anxiety than the males. Identification of the pre-operative anxiety in patients undergoing CABG surgery is essential because it helps the health professionals and nurses to develop effective and appropriate interventions. Keywords: Preoperative period, Anxiety, Coronary artery bypass, Perioperative care

  19. Anomalous origin of right coronary artery from left coronary sinus.

    Science.gov (United States)

    Hamzeh, Gadah; Crespo, Alex; Estarán, Rafael; Rodríguez, Miguel A; Voces, Roberto; Aramendi, José I

    2008-08-01

    Anomalous aortic origin of the coronary arteries is uncommon but clinically significant. Manifestations vary from asymptomatic patients to those who present with angina pectoris, myocardial infarction, heart failure, syncope, arrhythmias, and sudden death. We describe 4 patients, aged 34 to 59 years, who were diagnosed with right coronary artery arising from the left sinus of Valsalva, confirmed by coronary angiography, which was surgically repaired. Three patients presented dyspnea and angina, and one with acute myocardial infarction. At operation, the right coronary artery was dissected at the take-off from the intramural course, and reimplanted into the right sinus of Valsalva. There was no mortality. One patient had associated coronary artery disease that required stent placement postoperatively. This reimplantation technique provides a good physiological and anatomical repair, eliminates a slit-like ostium, avoids compression of the coronary artery between the aorta and the pulmonary artery, and gives superior results to coronary artery bypass grafting or the unroofing technique.

  20. Photoacoustic Soot Spectrometer (PASS) Instrument Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Dubey, M [Los Alamos National Laboratory; Springston, S [Brookhaven National Laboratory; Koontz, A [Pacific Northwest National Laboratory; Aiken, A [Los Alamos National Laboratory

    2013-01-17

    The photoacoustic soot spectrometer (PASS) measures light absorption by aerosol particles. As the particles pass through a laser beam, the absorbed energy heats the particles and in turn the surrounding air, which sets off a pressure wave that can be detected by a microphone. The PASS instruments deployed by ARM can also simultaneously measure the scattered laser light at three wavelengths and therefore provide a direct measure of the single-scattering albedo. The Operator Manual for the PASS-3100 is included here with the permission of Droplet Measurement Technologies, the instrument’s manufacturer.

  1. Video-assisted minimally invasive coronary operations without cardiopulmonary bypass : A multicenter study

    NARCIS (Netherlands)

    Benetti, F; Mariani, MA; Sani, G; Boonstra, PW; Grandjean, JG; Giomarelli, P; Toscano, M

    1996-01-01

    Objective: The need to avoid the risks associated with cardiopulmonary bypass has led to the interest in coronary operations without cardiopulmonary bypass, Patients and methods: From April 1994 to September 1995, 44 patients (mean age 63.3 +/- 10.0 years, range 43 to 83 years) were selected for

  2. The minimum coronary artery diameter in which coronary spasm can be identified by synchrotron radiation coronary angiography

    International Nuclear Information System (INIS)

    Matsushita, Shonosuke; Hyodo, Kazuyuki; Imazuru, Tomohiro; Tokunaga, Chiho; Sato, Fujio; Enomoto, Yoshiharu; Hiramatsu, Yuji; Sakakibara, Yuzuru

    2008-01-01

    Background: Coronary vasospasm is defined as a temporary, intense narrowing of the coronary conduit artery. It brings about ischemic chest pain and becomes one of the causes of myocardial infarction. Coronary spasms are divided into two categories. One is the coronary spasm of the conduit artery and the other is the coronary microvascular spasm. Although coronary spasms are diagnosed with the images of coronary angiography, microvascular spasms cannot be diagnosed because of the limitations of conventional angiographic systems. However, synchrotron radiation coronary angiography (SRCA) can identify coronary arteries down to 100 μm in diameter in the beating heart and 50 μm in arrested heart. Aim: The purpose of this study was to confirm whether microvascular spasms could be identified or not using SRCA, and then down that size identification was possible. Methods: The Langendorff perfusion system with isolated rat hearts was employed. Krebs-Henseleit solution (KH solution) was used as a perfusate. 10 mM of 4-aminopyridine (4-AP: a voltage-gated potassium channel blocker; spasm inducer) was added to the KH solution and maintained for 5 min. SRCA was performed at pre-, during and 10 min after cessation of the KH solution with 4-AP. Coronary spasms were defined as a temporal 75% reduction of coronary arterial diameter. Results and conclusion: Multiple sizes of coronary arteries showed coronary spasms. The minimum stenosed coronary artery size was 100 μm. Since coronary microvascular spasms are seen in the arterioles (50-400 μm), coronary microvascular spasms may be diagnosed with the use of synchrotron radiation coronary angiography

  3. Current status of hybrid coronary revascularization.

    Science.gov (United States)

    Jaik, Nikhil P; Umakanthan, Ramanan; Leacche, Marzia; Solenkova, Natalia; Balaguer, Jorge M; Hoff, Steven J; Ball, Stephen K; Zhao, David X; Byrne, John G

    2011-10-01

    Hybrid coronary revascularization combines coronary artery bypass surgery with percutaneous coronary intervention techniques to treat coronary artery disease. The potential benefits of such a technique are to offer the patients the best available treatments for coronary artery disease while minimizing the risks of the surgery. Hybrid coronary revascularization has resulted in the establishment of new 'hybrid operating suites', which incorporate and integrate the capabilities of a cardiac surgery operating room with that of an interventional cardiology laboratory. Hybrid coronary revascularization has greatly augmented teamwork and cooperation between both fields and has demonstrated encouraging as well as good initial outcomes.

  4. Congenital coronary artery anomalies: diagnosis with 64 slice multidetector row computed tomography coronary angiography: A single Centre Study

    International Nuclear Information System (INIS)

    Srnivasan, K.G.; Gaikward, A.; Kannan, B.R.J.; Ritesh, K.; Ushanandini, K.P.

    2008-01-01

    Full text: Retrospective review of the congenital coronary artery (CA) anomalies detected by a 64-slice multidetector row computed tomographic (MDCT) angiography. The type of the anomaly, imaging characteristics, clinical relevance and the superiority of the MDCT over conventional coronary angiography are discussed. Multidetector row computed tomographic coronary angiography was carried out by the usual technique with 70 cc of non-ionic contrast agent and retrospective electrocardiogram gating. The volume data obtained were reconstructed in axial plane, along with volume-rendered three-dimensional reconstruction and virtual angioscopy in selected patients. The images were analysed by a radiologist, experienced in cardiac CT, and an experienced cardiologist. A retrospective review of the records was carried out, and subjects with congenital coronary anomalies were included in the study. Between 15 November 2005 and 27 February 2007, 1495 MDCT coronary angiograms were carried out. Eleven of them were found to have coronary anomalies. Five had absent left main CA. Two had interarterial course of the left main CA artery passing in between the right ventricular outflow tract and the root of aorta. In one patient, there was aberrant origin of right CA from the left aortic sinus with subsequent interarterial course and another one had aberrant origin of circumflex artery from the right aortic sinus. One patient each of congenitally absent circumflex artery and atresia of the right CA were found. Sixty-four slice MDCT coronary angiography provided accurate depiction of anomalous vessel origin and course along with the complex anatomical relation with the adjacent structures. CTcan be considered as a first-line imaging method for delineating coronary arterial anomalies.

  5. Evaluation of pulmonary hypertension using first-pass radionuclide angiography in patients with valvular heart disease

    International Nuclear Information System (INIS)

    Wang Xuemei; Shi Rongfang; Pan Shiwei; Fang Wei; Wang Daoyu; Wang Qi; Zhang Hailong

    2003-01-01

    Objective: To evaluate pulmonary hypertension (PH) using first-pass radionuclide angiography in patients with valvular heart disease. Methods: One hundred and forty patients (54 males, 86 females, average age of 44.75±10.84) with valvular disease were included in this study. Swan-Ganz thermodilution catheterization, echocardiography and first-pass radionuclide angiography were performed on all patients before surgery. Patients were divided into four groups: pulmonary artery pressure (PAP) normal group [mean PAP (MPAP)<20 mm Hg(1mm Hg=0.133 kPa)]; PAP slightly risen group (20 mm Hg≤MPAP<30 mm Hg); PAP moderately risen group (30 mm Hg≤MPAP<50 mm Hg); PAP highly risen group (MPAP≥50 mm Hg). Thirteen subjects with coronary heart disease and 40 normal subjects (36 males, 17 females, average age of 46.30±11.19) were included as control group. First-pass radionuclide angiography was performed on these subjects, Swan-Ganz thermodilution catheterization was performed on patients with coronary heart disease. Results: 1) Lung equilibrium time (LET) values by first-pass radionuclide angiography were (16.88±5.12), (15.89±4.69), (18.56±3.04), (25.37±5.89), (37.69±6.25) and (61.33±10.14) s in coronary heart disease group, normal subject group and four valvular heart disease groups, respectively. The differences were significant among four valvular heart disease groups; and among control group, PAP slightly risen group, PAP moderately risen group, PAP highly risen group (P<0.001). 2) Correlation coefficient between LET and MPAP from the afloat catheter manometer was 0.88 and between systolic PAP (SPAP) from echocardiography and SPAP from the afloat catheter manometer was 0.64. 3) Agreement was 71%, 78%, 81%, 100% between LET and MPAP in four valvular heart disease groups, respectively. 4) Sensitivity, specificity and accuracy of PAP using LET measuring was 85%, 79% and 83%, respectively. Conclusion: First-pass radionuclide angiography is an accurate and noninvasive

  6. Myocardial flow reserve is influenced by both coronary artery stenosis severity and coronary risk factors in patients with suspected coronary artery disease

    International Nuclear Information System (INIS)

    Tsukamoto, Takahiro; Naya, Masanao; Tsutsui, Hiroyuki; Morita, Koichi; Katoh, Chietsugu; Inubushi, Masayuki; Kuge, Yuji; Tamaki, Nagara

    2006-01-01

    Myocardial flow reserve (MFR) measurement has an important role in assessing the functional severity of coronary artery stenosis. However, a discrepancy between the anatomical severity of coronary artery stenosis and MFR is often observed. Such a discrepancy may be explained by coronary risk factors. In this study, we aimed to investigate the influence of coronary artery stenosis severity and risk factors on MFR. Seventy-four patients suspected to have coronary artery disease and seven age-matched healthy volunteers were enrolled. Myocardial blood flow (MBF) and MFR were measured using 15 O-labelled water PET. Regional MFR was calculated in regions with significant coronary artery stenosis (stenotic regions) and in regions without significant stenosis (remote regions). The contributions of coronary artery stenosis severity and coronary risk factors were assessed using univariate and multivariate analyses. In stenotic regions, MFR correlated inversely with coronary artery stenosis severity (r=-0.50, p<0.01). Univariate analysis did not show any significant difference in MFR between the patients with and the patients without each risk factor. In remote regions, however, MFR was significantly decreased in the diabetes and smoking groups (each p<0.05). By multivariate analysis, diabetes and smoking were independent predictors of MFR (each p<0.05). In the group with more than one risk factor, MFR was significantly lower (2.78±0.79) than in the other group (3.40±1.22, p<0.05). MFR is influenced not only by coronary stenosis severity but also by coronary risk factors. In particular, the influence of risk factors should be considered in regions without severe coronary stenosis. (orig.)

  7. A First-Order One-Pass CPS Transformation

    DEFF Research Database (Denmark)

    Danvy, Olivier; Nielsen, Lasse Reichstein

    2002-01-01

    We present a new transformation of call-by-value lambdaterms into continuation-passing style (CPS). This transformation operates in one pass and is both compositional and first-order. Because it operates in one pass, it directly yields compact CPS programs that are comparable to what one would...... write by hand. Because it is compositional, it allows proofs by structural induction. Because it is first-order, reasoning about it does not require the use of a logical relation. This new CPS transformation connects two separate lines of research. It has already been used to state a new and simpler...... correctness proof of a direct-style transformation, and to develop a new and simpler CPS transformation of control-flow information....

  8. A comparison of hybrid coronary revascularization and off-pump coronary revascularization.

    Science.gov (United States)

    Umakanthan, Ramanan; Leacche, Marzia; Gallion, Anna H; Byrne, John G

    2013-04-01

    Minimally invasive approaches to treat vascular disease have been accruing significant popularity over the last several decades. Due to progressive advances in technology, a variety of techniques are being now utilized in the field of cardiovascular surgery. The objectives of minimally invasive techniques are to curtail operative trauma and minimize perioperative morbidity without decreasing the quality of the treatment. The standard surgical approach for the treatment of coronary artery disease has traditionally been coronary artery bypass grafting surgery via median sternotomy. Off-pump coronary artery bypass grafting surgery offers a less invasive alternative and enables coronary revascularization to be performed without cardiopulmonary bypass. Hybrid coronary revascularization offers an even less invasive option in which minimally invasive direct coronary artery bypass can be combined with percutaneous coronary intervention. In this article, the authors review a recent publication comparing hybrid coronary revascularization and off-pump coronary artery bypass grafting surgery.

  9. Statistical coronary motion models for 2D + t/3D registration of X-ray coronary angiography and CTA

    DEFF Research Database (Denmark)

    Baka, N.; Metz, C. T.; Schultz, C.

    2013-01-01

    Accurate alignment of intra-operative X-ray coronary angiography (XA) and pre-operative cardiac CT angiography (CTA) may improve procedural success rates of minimally invasive coronary interventions for patients with chronic total occlusions. It was previously shown that incorporating patient...... specific coronary motion extracted from 4D CTA increases the robustness of the alignment. However, pre-operative CTA is often acquired with gating at end-diastole, in which case patient specific motion is not available. For such cases, we investigate the possibility of using population based coronary...

  10. Device Performance Improvement of Double-Pass Wire Mesh Packed Solar Air Heaters under Recycling Operation Conditions

    Directory of Open Access Journals (Sweden)

    Chii-Dong Ho

    2016-01-01

    Full Text Available The improvement of device performance of a recycling solar air heater featuring a wire mesh packing was investigated experimentally and theoretically. The application of the wire mesh packing and recycle-effect concept to the present study were proposed aiming to strengthen the convective heat-transfer coefficient due to increased turbulence. Comparisons were made among different designs, including the single-pass, flat-plate double-pass and recycling double-pass wire mesh packed operations. The collector efficiency of the recycling double-pass wire mesh packed solar air heater was much higher than that of the other configurations for various recycle ratios and mass flow rates scenarios. The power consumption increment due to implementing wire mesh in solar air heaters was also discussed considering the economic feasibility. A fairly good agreement between theoretical predictions and experimental measurements was achieved with an analyzed error of 1.07%–9.32%.

  11. Coronary plaque quantification and fractional flow reserve by coronary computed tomography angiography identify ischaemia-causing lesions

    DEFF Research Database (Denmark)

    Gaur, Sara; Øvrehus, Kristian Altern; Dey, Damini

    2016-01-01

    AIMS: Coronary plaque characteristics are associated with ischaemia. Differences in plaque volumes and composition may explain the discordance between coronary stenosis severity and ischaemia. We evaluated the association between coronary stenosis severity, plaque characteristics, coronary computed...... tomography angiography (CTA)-derived fractional flow reserve (FFRCT), and lesion-specific ischaemia identified by FFR in a substudy of the NXT trial (Analysis of Coronary Blood Flow Using CT Angiography: Next Steps). METHODS AND RESULTS: Coronary CTA stenosis, plaque volumes, FFRCT, and FFR were assessed...

  12. [INTERVENTIONAL AND SURGICAL TREATMENT OF THE ANGINA PECTORIS RECURRENCE AFTER CORONARY SHUNTING OPERATION].

    Science.gov (United States)

    Fanta, S M

    2015-12-01

    There were examined 134 patients, in whom in the clinic in 2005-2014 yrs a coronary shunting operation was performed. In patients with the angina pectoris recurrence a reoperation is indicated. The data of repeated coronaroventriculography and shuntography were analyzed. Efficacy of the surgical and interventional methods application in the patients was proved.

  13. Prognosis of non-significant coronary atherosclerotic disease detected by coronary artery tomography

    Energy Technology Data Exchange (ETDEWEB)

    Barros, Marcio Vinicius Lins; Siqueira, Bruna Pinto; Guimaraes, Carolina Camargos Braichi; Cruz, David Filipe Silva; Guimaraes, Leiziane Assuncao Alves; Lima, Maicom Marcio Perigolo, E-mail: marciovlbarros@gmail.com [Faculdade de Saude e Ecologia Humana, Vespasiano, MG (Brazil); Nunes, Maria do Carmo Pereira [Universidade de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Faculdade de Medicina; Siqueira, Maria Helena Albernaz [Hospital Materdei, Belo Horizonte, MG (Brazil)

    2015-07-15

    Introduction: Although studies have shown high diagnostic accuracy of coronary tomography (CT) in detecting coronary artery disease (CAD), data on the prognostic value of this method in patients with no significant coronary obstruction are limited. Objective: To evaluate the value of CT in predicting adverse events in patients with suspected CAD and no significant coronary obstruction. Methods: We prospectively evaluated 440 patients between January 2008 and July 2013 by MDCT, diagnosed with no significant obstruction or no atherosclerotic coronary obstruction with an average follow-up of 33 months. The outcomes evaluated were: cardiac death, myocardial infarction, unstable angina associated with hospitalization or coronary artery bypass grafting. Results: Of the 440 patients studied, 295 (67%) were men with mean age 55.9 ± 12.0 years. Non-significant obstruction was found in 152 (35%) of the patients and there were 49 (11%) outcomes. In the multivariate analysis using the Cox regression model, the predictors of clinical outcomes were non-significant obstruction on CT (hazard ratio 3.51; 95% CI 1.73 - 7.8; p <0.01), age and hypertension. Non-significant obstruction on CT was associated with adverse clinical outcomes and survival analysis showed a significant difference (log-rank 24.6; p <0.01) in predicting these outcomes. Conclusion: The detection of non-significant atherosclerotic obstruction by CT was associated with the presence of adverse events in patients with suspected CAD, which may prove useful in the risk stratification of these patients. (author)

  14. The value of coronary artery calcium score assessed by dual-source computed tomography coronary angiography for predicting presence and severity of coronary artery disease

    International Nuclear Information System (INIS)

    Almasi, Alireza; Pouraliakbar, Hamidreza; Sedghian, Ahmad; Karimi, Mohammad Ali; Firouzi, Ata; Tehrai, Mahmood

    2014-01-01

    Measuring coronary artery calcium score (CACS) using a dual-source CT scanner is recognized as a major indicator for assessing coronary artery disease. The present study aimed to validate the clinical significance of CACS in predicting coronary artery stenosis and its severity. This prospective study was conducted on 202 consecutive patients who underwent both conventional coronary angiography and dual-source (256-slice) computed tomography coronary angiography (CTA) for any reason in our cardiac imaging center from March to September 2013. CACS was measured by Agatston algorithm on non-enhanced CT. The severity of coronary artery disease was assessed by Gensini score on conventional angiography. There was a significant relationship between the number of diseased coronary vessels and mean calcium score, i.e. the mean calcium score was 202.25±450.06 in normal coronary status, 427.50±607.24 in single-vessel disease, 590.03±511.34 in two-vessel disease, and 953.35±1023.45 in three-vessel disease (p<0.001). There was a positive association between calcium score and Gensini score (r=0.636, p<0.001). In a linear regression model, calcium score was a strong determinant of the severity of coronary artery disease. Calcium scoring had an acceptable value for discriminating coronary disease from normal condition with optimal cutoff point of 350, yielding a sensitivity and specificity of 83% and 70%, respectively. Our study confirmed the strong relationship between the coronary artery calcium score and the presence and severity of stenosis in coronary arteries assessed by both the number of diseased coronary vessels and also by the Gnesini score

  15. Congenital coronary artery fistula

    International Nuclear Information System (INIS)

    Oh, Yeon Hee; Kim, Hong; Zeon, Seoc Kil; Suh, Soo Jhi

    1986-01-01

    Congenital coronary artery fistula (CCAF) is communication of a coronary artery or its main branch with one of the atria or ventricles, the coronary sinus, the superior vena cava, or the pulmonary artery. In Korean peoples, only 4 cases of the CCAF were reported as rare as worldwide and authors want to report another case of CCAF, confirmed by operation. 10-year-old girl shows a fistula between sinus node artery of the right coronary artery and right atrium on root aortogram with left-to-right shunt and Qp/Qs=1.58, in which simple ligation of the sinus node artery from right coronary artery was performed. All of the 5 Korean CCAF (4 were previously reported and 1 of authors) were originated from right coronary artery, and of which 4 were opening into right ventricle and 1 of authors were into right atrium. Associated cardiac anomaly was noted in only 1 case as single coronary artery. Ages were from 9 months of age to 10 years old and no adult left case were found. 3 were female and 2 were male patients.

  16. Fabrication of seamless calandria tubes by cold pilgering route using 3-pass and 2-pass schedules

    Science.gov (United States)

    Saibaba, N.

    2008-12-01

    Calandria tube is a large diameter, extremely thin walled zirconium alloy tube which has diameter to wall thickness ratio as high as 90-95. Such tubes are conventionally produced by the 'welded route', which involves extrusion of slabs followed by a series of hot and cold rolling passes, intermediate anneals, press forming of sheets into circular shape and closing the gap by TIG welding. Though pilgering is a well established process for the fabrication of seamless tubes, production of extremely thin walled tubes offers several challenges during pilgering. Nuclear fuel complex (NFC), Hyderabad, has successfully developed a process for the production of Zircaloy-4 calandria tubes by adopting the 'seamless route' which involves hot extrusion of mother blanks followed by three-pass pilgering or two-pass pilgering schedules. This paper deals with standardization of the seamless route processes for fabrication of calandria tubes, comparison between the tubes produced by 2-pass and 3-pass pilgering schedules, role of ultrasonic test charts for control of process parameters, development of new testing methods for burst testing and other properties.

  17. Fabrication of seamless calandria tubes by cold pilgering route using 3-pass and 2-pass schedules

    International Nuclear Information System (INIS)

    Saibaba, N.

    2008-01-01

    Calandria tube is a large diameter, extremely thin walled zirconium alloy tube which has diameter to wall thickness ratio as high as 90-95. Such tubes are conventionally produced by the 'welded route', which involves extrusion of slabs followed by a series of hot and cold rolling passes, intermediate anneals, press forming of sheets into circular shape and closing the gap by TIG welding. Though pilgering is a well established process for the fabrication of seamless tubes, production of extremely thin walled tubes offers several challenges during pilgering. Nuclear fuel complex (NFC), Hyderabad, has successfully developed a process for the production of Zircaloy-4 calandria tubes by adopting the 'seamless route' which involves hot extrusion of mother blanks followed by three-pass pilgering or two-pass pilgering schedules. This paper deals with standardization of the seamless route processes for fabrication of calandria tubes, comparison between the tubes produced by 2-pass and 3-pass pilgering schedules, role of ultrasonic test charts for control of process parameters, development of new testing methods for burst testing and other properties

  18. Coronary ostium occlusion by coronary cusp displacement in Williams syndrome.

    Science.gov (United States)

    Shiohama, Tadashi; Fujii, Katsunori; Ebata, Ryota; Funabashi, Nobusada; Matsumiya, Goro; Saito, Yuko Kazato; Takechi, Fumie; Yonemori, Yoko; Nakatani, Yukio; Shimojo, Naoki

    2016-06-01

    Williams syndrome is a contiguous gene deletion syndrome resulting from a heterozygous deletion on chromosome 7q11.23, and is characterized by distinctive facial features and supravalvular aortic stenosis (SVAS). This syndrome rarely presents unpredictable cardiac death, and yet, as illustrated in the present case, it is still not possible to predict it, even on close monitoring. We herein describe the case of a 6-year-old Japanese girl with Williams syndrome, who had sudden cardiac collapse due to cardiac infarction after pharyngitis. Cardiac failure followed a critical course that did not respond to catecholamine support or heart rest with extracardiac mechanical support. Although marked coronary stenosis was not present, the left coronary cusp abnormally adhered to the aortic wall, which may synergistically cause coronary ostium occlusion with SVAS. Altered hemodynamic state, even that caused by the common cold, may lead to critical myocardial events in Williams syndrome with SVAS. © 2015 Japan Pediatric Society.

  19. Coronary angioscopy: a monorail angioscope with movable guide wire.

    Science.gov (United States)

    Nanto, S; Ohara, T; Mishima, M; Hirayama, A; Komamura, K; Matsumura, Y; Kodama, K

    1991-03-01

    A new angioscope was devised for easier visualization of the coronary artery. In its tip, the angioscope (Olympus) with an outer diameter of 0.8 mm had a metal lumen, through which a 0.014-in steerable guide wire passed. Using a 8F guiding catheter and a guide wire, it was introduced into the distal coronary artery. With injection of warmed saline through the guiding catheter, the coronary segments were visualized. In the attempted 70 vessels (32 left anterior descending [LAD], 10 right coronary [RCA], 28 left circumflex [LCX]) from 48 patients, 60 vessels (86%) were successfully examined. Twenty-two patients who underwent attempted examination of both LAD and LCX; both coronary arteries were visualized in 19 patients (86%). In the proximal site of the lesion, 40 patients have the diagonal branch or the obtuse marginal branch. In 34 patients (85%) the angioscope was inserted beyond these branches. In 12 very tortuous vessels, eight vessels (67%) were examined. In conclusion, the new monorail coronary angioscope with movable guide wire is useful to examine the stenotic lesions of the coronary artery.

  20. The thermal performance of the two-pass, two-glass-cover solar air heater

    Energy Technology Data Exchange (ETDEWEB)

    Persad, P.; Sateunanathan, S.

    1983-08-01

    Analytic models are developed for the performance prediction of a two-glass-cover solar air heater operated in both the single-pass and two-pass modes. It is shown that the two-pass mode of operation is superior to the single-pass mode of operation over the range of collector inlet temperatures considered. This is seen to be mainly due to the fact that, in the two-pass mode of operation, the outer glass cover is cooled by the working fluid, thereby reducing the top losses. It is also shown that the performance in the two-pass mode of operation is independent of length, over the range of collector lengths considered, and that a critical plate spacing, dependent on the temperature level of operation of the collector, is indicated. Predicted values of performance are in good agreement with experimental results.

  1. Evaluation of the restenosis of coronary artery after percutaneous transluminal coronary angioplasty by three-dimensional coronary magnetic resonance angiography

    International Nuclear Information System (INIS)

    Arisaka, Hiraku

    2000-01-01

    Coronary magnetic resonance angiography (MRA) has been recently brought into clinical use, however, there has not been reports on the comparison with MRA and conventional contrast coronary angiography (CAG) in the detection of the localization and characteristics of coronary restenosis after percutaneous transluminal coronary angioplasty (PTCA). To assess the restenosis of coronary artery after PTCA, this study compared three-dimensional (3D) coronary MRA and CAG. One hundred three patients (76 males and 27 females, average age of 64.6±9.3 years old) were performed coronary MRA at 3-6 months after PTCA. The right coronary artery (RCA) group consist of 21 patients, the left anterior descending branch (LAD) 63 patients and the left circumflex branch (LCX) 19 patients. Coronary MRA was performed with the patients in supine position on a 1.5 T whole body scanner (MAGNETOM VISION, Siemens AG, Germany) using body array coil. The imaging technique used a 3-D gradient echo sequence with respiratory gating and fat suppression. The slice thickness was 2 mm, slab thickness 32 mm, a field of view of 300 mm and a matrix of 128 x 256. Other parameters were an echo time of 2.7 ms and a repetition time of 600 to 1100 msec. The measurement time of 1 imaging slab took 15 to 20 minutes depending on the patient's heart rate. The coronary arteries were reconstructed from the 3-D data set using a multiplanar reconstruction (MPR) technique. According to previous coronary MRA studies, a significant stenosis with a luminal reduction of ≥50% was assumed if a marked signal reduction or signal loss of a vessel segment was visible. In CAG, 57 of 103 patients showed restenosis. In coronary MRA, 37 of 103 patients demonstrated restenosis. The sensitivity, specificity, positive and negative predictive values were 64.9%, 100%, 100% and 69.6%, respectively. Predictive accuracy was 79.6%. Three-dimensional coronary MRA is useful in a noninvasive diagnostic method to evaluate the coronary

  2. Coronary artery atherosclerosis associated with shift work in chemical plant workers by using coronary CT angiography.

    Science.gov (United States)

    Kang, WonYang; Park, Won-Ju; Jang, Keun-Ho; Kim, Soo-Hyeon; Gwon, Do-Hyeong; Lim, Hyeong-Min; Ahn, Ji-Sung; Moon, Jai-Dong

    2016-08-01

    The aim of this study was to investigate whether shift work is related to elevated risk of coronary artery disease (CAD) by determining the coronary artery calcium (CAC) score and the presence of coronary artery stenosis by using coronary artery CT angiography (CCTA). In this study, 110 male workers participated and underwent a CCTA examination for CAC scoring, which represents coronary artery plaque, and were evaluated for luminal stenosis. All of the participants were working in the same chemical plant, of whom 70 worked day shifts and 40 worked rotating shifts. In a multivariate logistic regression analysis, including age, smoking status, alcohol consumption, regular exercise and waist circumference, shift work was associated with a 2.89-fold increase in the odds of developing coronary plaque compared with day work (OR, 2.89; 95% CI 1.07 to 7.82). The association between shift work and coronary plaque was strong after adjustment for age, low-density lipoprotein cholesterol, hypertension and diabetes mellitus (OR, 2.92; 95% CI 1.02 to 8.33). In addition, the number of years of shift work employment was associated with coronary plaque. However, no association was found between shift work and coronary artery stenosis. Shift work could induce CAD onset via the atherosclerotic process, and shift work employment duration was associated with an increased risk of atherosclerosis in male workers. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  3. Prognostic assessment of stable coronary artery disease as determined by coronary computed tomography angiography

    DEFF Research Database (Denmark)

    Hüche Nielsen, Lene; Bøtker, Hans Erik; Sørensen, Henrik T.

    2017-01-01

    Aims: To examine the 3.5 year prognosis of stable coronary artery disease (CAD) as assessed by coronary computed tomography angiography (CCTA) in real-world clinical practice, overall and within subgroups of patients according to age, sex, and comorbidity. Methods and results: This cohort study......, and comorbidity. Conclusion: Coronary artery disease determined by CCTA in real-world practice predicts the 3.5 year composite risk of late revascularization, myocardial infarction, and all-cause death across different groups of age, sex, or comorbidity burden....... included 16,949 patients (median age 57 years; 57% women) with new-onset symptoms suggestive of CAD, who underwent CCTA between January 2008 and December 2012. The endpoint was a composite of late coronary revascularization procedure >90 days after CCTA, myocardial infarction, and all-cause death...

  4. [Development of an automated processing method to detect coronary motion for coronary magnetic resonance angiography].

    Science.gov (United States)

    Asou, Hiroya; Imada, N; Sato, T

    2010-06-20

    On coronary MR angiography (CMRA), cardiac motions worsen the image quality. To improve the image quality, detection of cardiac especially for individual coronary motion is very important. Usually, scan delay and duration were determined manually by the operator. We developed a new evaluation method to calculate static time of individual coronary artery. At first, coronary cine MRI was taken at the level of about 3 cm below the aortic valve (80 images/R-R). Chronological change of the signals were evaluated with Fourier transformation of each pixel of the images were done. Noise reduction with subtraction process and extraction process were done. To extract higher motion such as coronary arteries, morphological filter process and labeling process were added. Using these imaging processes, individual coronary motion was extracted and individual coronary static time was calculated automatically. We compared the images with ordinary manual method and new automated method in 10 healthy volunteers. Coronary static times were calculated with our method. Calculated coronary static time was shorter than that of ordinary manual method. And scan time became about 10% longer than that of ordinary method. Image qualities were improved in our method. Our automated detection method for coronary static time with chronological Fourier transformation has a potential to improve the image quality of CMRA and easy processing.

  5. Magnetic Resonance Imaging Measurement of Left Ventricular Blood Flow and Coronary Flow Reserve in Patients with Chronic Heart Failure due to Coronary Artery Disease

    International Nuclear Information System (INIS)

    Aras, A.; Anik, Y.; Demirci, A.; Balci, N.C.; Kozdag, G.; Ural, D.; Komsuogl u, B.

    2007-01-01

    Background: Coronary sinus flow reflects global cardiac perfusion and has been used for the assessment of myocardial flow reserve, which is reduced in chronic heart failure (CHF). Coronary flow reserve (CFR) can be measured by using phase-contrast (PC) velocity-encoded cine (VEC) magnetic resonance imaging (MRI). Purpose: To quantify and compare global left ventricular (LV) perfusion and CFR in patients with CHF and in a healthy control group by measuring coronary sinus flow with PC VEC MRI, and to correlate this with global LV perfusion, segmental first-pass perfusion, and viability in the same patients. Material and Methods: Cardiac MRI was performed in 20 patients with CHF of ischemic origin and in a control group of healthy subjects (n 11) at rest and after pharmacological stress induced by i.v. dipyridamole. The MRI protocol included cine MRI, VEC MRI, first-pass perfusion, and delayed contrast-enhanced MRI for viability. Global LV perfusion was quantified by measuring coronary sinus flow on VEC MRI at rest in all subjects. CFR was determined as the ratio of global LV perfusion before and after pharmacologic stress. Results: At rest, global LV perfusion was not significantly different in patients with CHF and the control group. After administration of dipyridamole, global LV perfusion and CFR were significantly lower in patients with CHF compared to the control group (P<0.001). An inverse correlation was observed between CFR and the number of infarcted and/or ischemic segments (P = 0.083, P 0.037). Conclusion: A combined cardiac MRI protocol including function and perfusion techniques together with VEC MRI can be used to evaluate global LV perfusion and CFR in patients with CHF. Global LV perfusion and CFR measurements may have potential in the monitoring of CHF. Impaired CFR may contribute to progressive decline in LV function in patients with CHF

  6. Magnetic Resonance Imaging Measurement of Left Ventricular Blood Flow and Coronary Flow Reserve in Patients with Chronic Heart Failure due to Coronary Artery Disease

    Energy Technology Data Exchange (ETDEWEB)

    Aras, A.; Anik, Y.; Demirci, A.; Balci, N.C.; Kozdag, G.; Ural, D.; Komsuoglu, B. (Radiology Dept. and Cardiology Dept., Kocaeli Univ. School of Medicine, Kocaeli (Turkey))

    2007-11-15

    Background: Coronary sinus flow reflects global cardiac perfusion and has been used for the assessment of myocardial flow reserve, which is reduced in chronic heart failure (CHF). Coronary flow reserve (CFR) can be measured by using phase-contrast (PC) velocity-encoded cine (VEC) magnetic resonance imaging (MRI). Purpose: To quantify and compare global left ventricular (LV) perfusion and CFR in patients with CHF and in a healthy control group by measuring coronary sinus flow with PC VEC MRI, and to correlate this with global LV perfusion, segmental first-pass perfusion, and viability in the same patients. Material and Methods: Cardiac MRI was performed in 20 patients with CHF of ischemic origin and in a control group of healthy subjects (n 11) at rest and after pharmacological stress induced by i.v. dipyridamole. The MRI protocol included cine MRI, VEC MRI, first-pass perfusion, and delayed contrast-enhanced MRI for viability. Global LV perfusion was quantified by measuring coronary sinus flow on VEC MRI at rest in all subjects. CFR was determined as the ratio of global LV perfusion before and after pharmacologic stress. Results: At rest, global LV perfusion was not significantly different in patients with CHF and the control group. After administration of dipyridamole, global LV perfusion and CFR were significantly lower in patients with CHF compared to the control group (P<0.001). An inverse correlation was observed between CFR and the number of infarcted and/or ischemic segments (P = 0.083, P = 0.037). Conclusion: A combined cardiac MRI protocol including function and perfusion techniques together with VEC MRI can be used to evaluate global LV perfusion and CFR in patients with CHF. Global LV perfusion and CFR measurements may have potential in the monitoring of CHF. Impaired CFR may contribute to progressive decline in LV function in patients with CHF

  7. A case of transient central diabetes insipidus after aorto-coronary bypass operation.

    Science.gov (United States)

    Yu, Chung-Hoon; Cho, Jang-Hee; Jung, Hee-Yeon; Lim, Jeong-Hoon; Jin, Mi-Kyung; Kwon, Owen; Hong, Kyung-Deuk; Choi, Ji-Young; Yoon, Se-Hee; Kim, Chan-Duck; Kim, Yong-Lim; Kim, Gun-Jik; Park, Sun-Hee

    2012-09-01

    Diabetes insipidus (DI) is characterized by excessive urination and thirst. This disease results from inadequate output of antidiuretic hormone (ADH) from the pituitary gland or the absence of the normal response to ADH in the kidney. We present a case of transient central DI in a patient who underwent a cardiopulmonary bypass (CPB) for coronary artery bypass grafting (CABG). A 44-yr-old male underwent a CABG operation. An hour after the operation, the patient developed polyuria and was diagnosed with central DI. The patient responded to desmopressin and completely recovered five days after surgery. It is probable that transient cerebral ischemia resulted in the dysfunction of osmotic receptors in the hypothalamus or hypothalamus-pituitary axis during CPB. It is also possible that cardiac standstill altered the left atrial non-osmotic receptor function and suppressed ADH release. Therefore, we suggest that central DI is a possible cause of polyuria after CPB.

  8. Takayasu Arteritis of the Coronary Arteries Presenting as Sudden Death in a White Teenager.

    Science.gov (United States)

    Hlavaty, Leigh; Diaz, Francisco; Sung, LokMan

    2015-09-01

    Takayasu arteritis is a rare disease that expresses chronic, large vessel inflammation. The etiology remains unclear and its presentation depends on the affected arteries. With coronary artery involvement, manifestations range from chest pain and shortness of breath to sudden death. We report a case of a 15-year-old white girl who presented with syncope immediately before passing. On autopsy, all 3 major coronary arteries grossly contained multiple proximal lesions that were consistent with Takayasu arteritis, microscopically. Takayasu arteritis solely affecting multiple coronary arteries is exceedingly rare. This report discusses the significance of coronary involvement in Takayasu arteritis at autopsy and sudden death.

  9. The Use of Tygon Tubing Sterilized by Gamma Radiation in Heart-Lung By-Pass Machines

    Energy Technology Data Exchange (ETDEWEB)

    Alladine, M. F.; Gibbons, J. R. P. [London Chest Hospital, London (United Kingdom)

    1967-09-15

    Tygon tubing is a co-polymer polyvinyl chloride. This tubing is used throughout the circuit of our heart-lung by-pass machines and had been sterilized by autoclaving or exposure to ethylene oxide gas. Tubing sterilized by autoclaving was noted to have a decrease in tensile strength and the transparency of the tubing was affected. Sterilization by ethylene oxide had the disadvantage that gas was often present in the lumen of the tube when connected to the machine. Lengths of Tygon tubing were sterilized by gamma radiation at varying radiation levels and temperatures. Bacteriological studies were done on the tubing and estimation of tensile strength carried out. We have found that a level of radiation of 2. 5 to 3. 0 Mrad at 20°C produces little or no change in tensile strength and the tubing remains bacteriologically sterile. Tygon tubing sterilized in this way has now been used in over sixty heart-lung by-pass machine operations. (author)

  10. Association between smoking habits and severity of coronary stenosis as assessed by coronary computed tomography angiography.

    Science.gov (United States)

    Yano, Masaya; Miura, Shin-Ichiro; Shiga, Yuhei; Miyase, Yuiko; Suematsu, Yasunori; Norimatsu, Kenji; Nakamura, Ayumi; Adachi, Sen; Nishikawa, Hiroaki; Saku, Keijiro

    2016-07-01

    Smoking promotes arteriosclerosis and is one of the most important coronary risk factors. However, few studies have investigated the association between smoking habits and the severity of coronary stenosis as assessed by coronary computed tomography angiography (CTA). We enrolled 416 patients [165/251 = smoker (past and current)/non-smoker)]. They had all undergone CTA and either were clinically suspected of having coronary artery disease (CAD) or had at least one cardiovascular risk factor. We divided the patients into smoking and non-smoking groups, and evaluated the presence of CAD, the number of significantly stenosed coronary vessels (VD), and the Gensini score as assessed by CTA in the two groups. The incidence of CAD, VD, the Gensini score, and coronary calcification score in the smoking group were all significantly greater than those in the non-smoking group (CAD, p = 0.009; VD, p = 0.003; Gensini score, p = 0.007; coronary calcification score, p = 0.01). Pack-year was significantly associated with VD and the Gensini score, and was strongly associated with multi-vessel disease (2- and 3-VD) (p < 0.05), whereas the duration of cessation in past smokers was not associated with VD or the Gensini score. Pack-year, but not the duration of cessation, may be the most important factor that was associated with the severity of coronary stenosis in terms of VD and the Gensini score.

  11. Combined evaluation of first-pass radionuclide angiography and epuilibrium radionuclide ventriculography in the diagnosis of coronary artery disease. Pt. 1

    International Nuclear Information System (INIS)

    Knesewitsch, P.; Kleinhans, E.; Buell, U.

    1986-01-01

    The results of 203 patients who underwent first-pass radionuclide angiography (FP), as well as quantitative equilibrium radionuclide ventriculography (qERNV), were stored in a data base system and evaluated statistically. In patients with coronary artery disease (CAD) without previous myocardial infarction (MI), evaluation of global and regional ejection fraction (gEF, rEF) at rest revealed a poor sensitivity of 64% (Rest-qERNV) and 69% (Rest-FP), respectively. In patients with a history of one previous MI, the sensitivity of both methods was equivalent: FP 87% and qERNV 84%. In patients with several MIs, sensitivity was higher than 90%. Concerning localization of MI, remarkable differences between FP and qERNV were found. In posterior wall infarction, the FP sensitivity was 87% and qERNV only 67%, whereas in anterior wall infarction, the results were similar for both methods.: 93% (FP) and 96% (qERNV), respectively. Since 30 0 RAO camera position achieves the best visualization of the anterior and posterior wall, FP is superior to qERNV in the evaluation of posterior wall asynergies. In addition, qERNV often fails to discriminate anterior and posterior wall motion abnormalities. (orig.)

  12. Single coronary artery; extremely rare coronary anomaly successfully treated surgically in young adult male.

    LENUS (Irish Health Repository)

    Shah, A R

    2010-05-01

    Single coronary artery arising from aortic root, is a rare congenital anomaly. A 30-year-old male presented with acute myocardial infarction (MI) complaining of chest pain and raised troponin levels. Emergency angiography showed no coronary lesions but both left and right coronary arteries arising from single ostium. Patient was operated electively and perioperative findings confirmed the diagnosis of single coronary artery, as left coronary artery after taking origin from right sinus of valsalva runs through the septum, before dividing into left anterior descending and circumflex branches. The single coronary ostium opened with a slit like incision over the course of left main coronary, making the size of ostium three to four times bigger than the native one. In addition left internal mammary artery was harvested and grafted to the left anterior descending branch distally. Patient made successful recovery. Four months follow up dobutamine stress echo showed no inducible ischemia.

  13. Morphological study on coronary ostial and clinicoangiographic analysis of isolated coronary ostial stenosis

    International Nuclear Information System (INIS)

    Kanoh, Tatsuji

    2007-01-01

    A morphological study of coronary ostia was performed in 70 autopsied human hearts, with particular attention being focused on the funnel-shaped structure, aging changes, and relation to atherosclerosis. The following results were obtained: The ostium is particularly well-defined and forms a funnel-shaped structure. The structure is predominantly a double circular shape on the right and comet-shaped on the left. The funnel-shaped structure of coronary ostia is characterized by a longitudinal smooth muscle arrangement in the inner layer and circular one in the outer layer. Including overhang formation, coronary sclerosis of the ostium appears mainly on the upper margin of the funnel-shaped structure of the right ostium and at the upper right margin of the left. In ischemic heart disease, along with changes in coronary arteries themselves, changes in the ostia of these arteries should be paid close attention. Ostial stenosis of the coronary artery in the absence of distal vessel obstructions, isolated ostial stenosis, is a rare form of coronary artery disease. In a previous review of the international literature, the incidence of coronary ostial stenosis varied between 0.13% and 2.7%. Among 7,500 patients undergoing selective coronary cineangiography at Juntendo University Hospital and Juntendo Urayasu Hospital from 1975 to 1990, five women (0.07%) were diagnosed as having ''isolated coronary ostial stenosis'', of which the cause is unknown. Atherosclerosis, particularly early premature atherome, congenital coronary anomaly, fibro-muscular dysplasia, Takayasu's aortitis, humoral factors, spasm, and iatrogenic events have been considered as its causes. In contrast to usual atherosclerotic coronary artery disease, patients with isolated coronary ostial stenosis of unknown etiology were characterized as being middle-aged, premenopausal, slender females having few coronary risk factors, experiencing severe angina pector is with marked ischemic electrocardiogram changes

  14. Evaluation of Coronary Artery Stenosis by Quantitative Flow Ratio During Invasive Coronary Angiography

    DEFF Research Database (Denmark)

    Westra, Jelmer; Tu, Shengxian; Winther, Simon

    2018-01-01

    BACKGROUND: Quantitative flow ratio (QFR) is a novel diagnostic modality for functional testing of coronary artery stenosis without the use of pressure wires and induction of hyperemia. QFR is based on computation of standard invasive coronary angiographic imaging. The purpose of WIFI II (Wire...... patients with suspected coronary artery disease on coronary computed tomographic angiography for diagnostic invasive coronary angiography. Fractional flow reserve (FFR) was measured in all segments with 30% to 90% diameter stenosis. Blinded observers calculated QFR (Medis Medical Imaging bv......, The Netherlands) for comparison with FFR. FFR was measured in 292 lesions from 191 patients. Ten (5%) and 9 patients (5%) were excluded because of FFR and angiographic core laboratory criteria, respectively. QFR was successfully computed in 240 out of 255 lesions (94%) with a mean diameter stenosis of 50...

  15. Cyanotic Congenital Heart Disease The Coronary Arterial Circulation

    Science.gov (United States)

    Perloff, Joseph K

    2012-01-01

    Background: The coronary circulation in cyanotic congenital heart disease (CCHD) includes the extramural coronary arteries, basal coronary blood flow, flow reserve, the coronary microcirculation, and coronary atherogenesis. Methods: Coronary arteriograms were analyzed in 59 adults with CCHD. Dilated extramural coronaries were examined histologically in six patients. Basal coronary blood flow was determined with N-13 positron emission tomography in 14 patients and in 10 controls. Hyperemic flow was induced by intravenous dipyridamole pharmacologic stress. Immunostaining against SM alpha-actin permitted microcirculatory morphometric analysis. Non-fasting total cholesterols were retrieved in 279 patients divided into four groups: Group A---143 cyanotic unoperated, Group B---47 rendered acyanotic by reparative surgery, Group C---41 acyanotic unoperated, Group D---48 acyanotic before and after operation. Results: Extramural coronary arteries were mildly or moderately dilated to ectatic in 49/59 angiograms. Histologic examination disclosed loss of medial smooth muscle, increased medial collagen, and duplication of internal elastic lamina. Basal coronary flow was appreciably increased. Hyperemic flow was comparable to controls. Remodeling of the microcirculation was based upon coronary arteriolar length, volume and surface densities. Coronary atherosclerosis was absent in both the arteriograms and the necropsy specimens. Conclusions: Extramural coronary arteries in CCHD dilate in response to endothelial vasodilator substances supplemented by mural attenuation caused by medial abnormalities. Basal coronary flow was appreciably increased, but hyperemic flow was normal. Remodeling of the microcirculation was responsible for preservation of flow reserve. The coronaries were atheroma-free because of the salutory effects of hypocholesterolemia, hypoxemia, upregulated nitric oxide, low platelet counts, and hyperbilirubinrmia. PMID:22845810

  16. Reverse 201Tl myocardial redistribution induced by coronary artery spasm

    International Nuclear Information System (INIS)

    Xiang Dingcheng; Yin Jilin; Gong Zhihua; Xie Zhenhong; Zhang Jinhe; Wen Yanfei; Yi Shaodong

    2010-01-01

    Objective: To investigate the mechanism of reverse redistribution (RR) on dipyridamole 201 Tl myocardial perfusion studies in the patients with coronary artery spasm. Methods: Twenty-six patients with coronary artery spasm and presented as RR on dipyridamole 201 Tl myocardial perfusion studies were enlisted as RR group, while other 16 patients with no coronary artery stenosis nor RR were enlisted as control group. Dipyridamole test was repeated during coronary angiography. Corrected thrombolysis in myocardial infarction (TIMI) frame count (CTFC) and TIMI myocardial perfusion grade (TMPG) were measured at RR related and non-RR related coronary arteries before and after dipyridamole infusion respectively. All of the data were analyzed by Student's t-test or χ 2 -test and correlation analysis. Results: Coronary artery angiography showed slower blood flow and lower myocardial perfusion in RR related vessels when compared with non-RR related vessels in RR group, but there was no significant difference among the main coronary arteries in control group. The perfusion defects of RR area at rest were positively related to slower blood velocity at corresponding coronary arteries (r = 0.79, t =10.18, P 0.05). Conclusion: RR is related to the decreased blood flow and myocardial perfusion induced by coronary artery spasm at rest, which may be improved by stress test such as intravenous dipyridamole infusion. (authors)

  17. Prognostic value of coronary atherosclerosis progression evaluated by coronary CT angiography in patients with stable angina

    International Nuclear Information System (INIS)

    Gu, Hui; Gao, Yang; Hou, Zhihui; Lu, Bin; Schoepf, U.J.; Snyder, Alan N.; Duguay, Taylor M.; Wang, Ximing

    2018-01-01

    To investigate the progression of coronary atherosclerosis burden by coronary CT angiography (CCTA) and to demonstrate its association with the incidence of major adverse cardiac events (MACE). We retrospectively studied patients with stable angina who had undergone repeat CCTA due to recurrent or worsening symptoms. Lipid-rich, fibrous, calcified and total plaque burden as well as coronary diameter stenosis were quantitatively analysed. The incidence of MACE during follow-up was determined. The final cohort consisted of 268 patients (mean age 52.9 ± 9.8 years, 71 % male) with a mean follow-up period of 4.6 ± 0.9 years. Patients with lipid-rich, fibrous, calcified and total plaque burden (%) progression, as well as coronary diameter stenosis (%) progression had a significantly higher incidence of MACE than those without (all p < 0.05). The progression of lipid-rich plaque (HR = 1.601, p = 0.021), total plaque burden (HR = 2.979, p = 0.043) and coronary diameter stenosis (HR = 4.327, p <0.001) were independent predictors of MACE (all p < 0.05). Patients presenting with recurrent or worsening symptoms associated with coronary artery disease who have coronary atherosclerosis progression on CCTA are at an increased risk of future MACE. (orig.)

  18. Prognostic value of coronary atherosclerosis progression evaluated by coronary CT angiography in patients with stable angina

    Energy Technology Data Exchange (ETDEWEB)

    Gu, Hui [Shandong University, Department of CT, Shandong Provincial Key Laboratory of Diagnosis and Treatment of Cardio-Cerebral Vascular Diseases, Shandong Medical Imaging Research Institute, Jinan, Shandong (China); Chinese Academy of Medical Sciences and Peking Union Medical College, Department of Radiology, Fuwai Hospital, State Key Laboratory of Cardiovascular Disease, National Centre for Cardiovascular Diseases, Beijing (China); Gao, Yang; Hou, Zhihui; Lu, Bin [Chinese Academy of Medical Sciences and Peking Union Medical College, Department of Radiology, Fuwai Hospital, State Key Laboratory of Cardiovascular Disease, National Centre for Cardiovascular Diseases, Beijing (China); Schoepf, U.J.; Snyder, Alan N.; Duguay, Taylor M. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Wang, Ximing [Shandong University, Department of CT, Shandong Provincial Key Laboratory of Diagnosis and Treatment of Cardio-Cerebral Vascular Diseases, Shandong Medical Imaging Research Institute, Jinan, Shandong (China)

    2018-03-15

    To investigate the progression of coronary atherosclerosis burden by coronary CT angiography (CCTA) and to demonstrate its association with the incidence of major adverse cardiac events (MACE). We retrospectively studied patients with stable angina who had undergone repeat CCTA due to recurrent or worsening symptoms. Lipid-rich, fibrous, calcified and total plaque burden as well as coronary diameter stenosis were quantitatively analysed. The incidence of MACE during follow-up was determined. The final cohort consisted of 268 patients (mean age 52.9 ± 9.8 years, 71 % male) with a mean follow-up period of 4.6 ± 0.9 years. Patients with lipid-rich, fibrous, calcified and total plaque burden (%) progression, as well as coronary diameter stenosis (%) progression had a significantly higher incidence of MACE than those without (all p < 0.05). The progression of lipid-rich plaque (HR = 1.601, p = 0.021), total plaque burden (HR = 2.979, p = 0.043) and coronary diameter stenosis (HR = 4.327, p <0.001) were independent predictors of MACE (all p < 0.05). Patients presenting with recurrent or worsening symptoms associated with coronary artery disease who have coronary atherosclerosis progression on CCTA are at an increased risk of future MACE. (orig.)

  19. Coronary spasm induced by dipyridamole

    International Nuclear Information System (INIS)

    Wartski, M.; Caussin, C.; Lancelin, B.

    2001-01-01

    A 59 years old man was admitted at hospital for recurrent instable angina 1 month after coronary artery bypass surgery. Coronary artery disease started with a transmural antero-septo-apical myocardial infarction without thrombolysis and a percutaneous angioplasty with endo-prothesis on proximal left anterior descendant artery (LAD) is performed Because of recurrent rest angina and subacute stent thrombosis, a coronary artery bypass surgery (CABG) is performed with anastomosis of the left internal thoracic artery on LAD. The patient is admitted for recurrent rest angina one month after CABG. On ECG performed during chest pain, a ST-T segment elevation occurred on inferior leads. Coronary angiography showed no significant stenosis on endo-prothesis and no bypass graft dysfunction. Dipyridamole scintigraphy was realized. 2 minutes after the beginning of Dipyridamole infusion, a ST-T elevation occurred on inferior leads and two marked antero-septal and inferior defects were noticed on myocardial scintigraphy. Images at rest showed a clear improvement in the anterior wall and the inferior wall became normally perfused Patient was treated with anti-spastic drugs and a new coronarography with methyl-ergotamine test was performed inducing chest pain, ST-T elevation on inferior leads and tri-truncular coronary spasm. Patient's treatment was then modified with introduction of Nifedipine. The patient did not experienced new recurrent chest pain and remained totally asymptomatic few months later. (authors)

  20. Additional diagnostic value of systolic dysfunction induced by dipyridamole stress cardiac magnetic resonance used in detecting coronary artery disease.

    Science.gov (United States)

    Husser, Oliver; Bodí, Vicente; Sanchís, Juan; Mainar, Luis; Núñez, Julio; López-Lereu, María P; Monmeneu, José V; Ruiz, Vicente; Rumiz, Eva; Moratal, David; Chorro, Francisco J; Llácer, Angel

    2009-04-01

    Dipyridamole stress perfusion cardiovascular magnetic resonance (CMR) is used to detect coronary artery disease (CAD). However, few data are available on the diagnostic value of the systolic dysfunction induced by dipyridamole. This study investigated whether the induction of systolic dysfunction supplements the diagnostic information provided by perfusion imaging in the detection of CAD. Overall, 166 patients underwent dipyridamole CMR and quantitative coronary angiography, with CAD being defined as a stenosis > or =70%. Systolic dysfunction at rest, systolic dysfunction with dipyridamole, induced systolic dysfunction, and stress first-pass perfussion deficit (PD) and delayed enhancement were quantified. In the multivariate analysis, PD (hazard ratio [HR]=1.6; 95% confidence interval [CI], 1.33-1.91;Pstatistic for predicting CAD (0.81 vs. 0.87; P=.02). Combining induced systolic dysfunction with perfusion imaging increases the diagnostic accuracy of detecting CAD and enables patients with severe ischemia and a high probability of CAD to be identified.

  1. Analysis for Involvement of TPP Operating in Accordance with Heating Schedule to Passing Through Failures of Electric Load Schedules

    Directory of Open Access Journals (Sweden)

    V. I. Nazarov

    2013-01-01

    Full Text Available The paper describes technical and economic evaluation of various methods pertaining to passing through failures of electric load at TPP which is operating in accordance with heating schedule.

  2. Noninvasive assessment of coronary collaterals in man by PET perfusion imaging

    International Nuclear Information System (INIS)

    Demer, L.L.; Gould, K.L.; Goldstein, R.A.; Kirkeeide, R.L.

    1990-01-01

    At present, coronary collateralization cannot be identified or assessed noninvasively in patients. In animal studies, coronary collaterals are associated with coronary steal, defined as a regional fall in perfusion during coronary arteriolar vasodilation. To determine the effect of coronary arteriolar vasodilation on collateral bed perfusion in man, myocardial perfusion imaging was performed before and after pharmacologic coronary vasodilation in patients with coronary artery disease (CAD). Regional myocardial activity of 82 Rb or 13 N ammonia was measured by positron emission tomography (PET) at rest and with intravenous dipyridamole/handgrip stress in 28 patients with angiographic collaterals and in 25 control patients with similar CAD severity by quantitative arteriography. Regional myocardial activity decreased after dipyridamole, indicating coronary steal, in 25 of 28 patients with angiographic collaterals and in only 4 of 25 control patients without angiographic collaterals. These findings suggest that developed collaterals are associated with myocardial steal in patients with CAD, allowing potential use of PET for non-invasive identification of coronary collateralization

  3. Improved diagnostic performance of exercise thallium-201 single photon emission computed tomography over planar imaging in the diagnosis of coronary artery disease: a receiver operating characteristic analysis

    International Nuclear Information System (INIS)

    Fintel, D.J.; Links, J.M.; Brinker, J.A.; Frank, T.L.; Parker, M.; Becker, L.C.

    1989-01-01

    Qualitative interpretation of tomographic and planar scintigrams, a five point rating scale and receiver operating characteristic analysis were utilized to compare single photon emission computed tomography and conventional planar imaging of myocardial thallium-201 uptake in the accuracy of the diagnosis of coronary artery disease and individual vessel involvement. One hundred twelve patients undergoing cardiac catheterization and 23 normal volunteers performed symptom-limited treadmill exercise, followed by stress and redistribution imaging by both tomographic and planar techniques, with the order determined randomly. Paired receiver operating characteristic curves revealed that single photon emission computed tomography was more accurate than planar imaging over the entire range of decision thresholds for the overall detection and exclusion of coronary artery disease and involvement of the left anterior descending and left circumflex coronary arteries. Tomography offered relatively greater advantages in male patients and in patients with milder forms of coronary artery disease, who had no prior myocardial infarction, only single vessel involvement or no lesion greater than or equal to 50 to 69%. Tomography did not appear to provide improved diagnosis in women or in detection of disease in the right coronary artery. Although overall detection of coronary artery disease was not improved in patients with prior myocardial infarction, tomography provided improved identification of normal and abnormal vascular regions. These results indicate that single photon emission computed tomography provides improved diagnostic performance compared with planar imaging in many clinical subgroups

  4. Evaluation of myocardial bridging by coronary computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Barros, Marcio Vinicius Lins; Rabelo, Daniel Rocha; Siqueira, Maria Helena Albernaz, E-mail: marciovlbarros@uol.com.br [Hospital Mater Dei, Belo Horizonte, MG (Brazil); Garretto, Luiza Samarane; Paula, Marcela Mascarenhas De; Carvalho, Marina Oliveira; Alves, Marina Rangel Moreira Barros [Faculdade de Saude e Ecologia Humana (FASEH), Vespasiano, MG (Brazil)

    2013-01-15

    The myocardial bridge (MB) is defined as a segment of an epicardial coronary artery that has an intramural course in the myocardium. Although MB is clinically silent in most cases, has been associated with myocardial ischemia, arrhythmias and sudden death. Coronary conventional angiography is the gold standard for detection of MB, but is invasive and cannot be sufficiently sensitive compared to autopsy studies. Recently, multislice computed tomography of coronary arteries (MCTCA) has allowed the detection of coronary artery course, including PM. Objectives: to evaluate MB prevalence in patients with suspected coronary artery disease undergoing MCTCA and to evaluate the predictive value of this method at medium term. Methods: during the period 2008 to 2011, 498 consecutive patients were examined by TMC for the diagnosis of coronary artery disease, being conducted to evaluate the presence of BM and followed for a mean follow-up of 23 months for the occurrence of cardiovascular hard events (death, hospitalization or revascularization). Results: patients mean age was 55.3 ± 14.2, being male 71.1%. Among the patients, 7.6% (38 patients) showed MB. Main findings included angina pectoris in 40% and a positive stress test in 34%. 34.2% had atherosclerotic disease, and one patient had significant coronary stenosis. During follow-up, no patients showed adverse events. Conclusion: MCTCA is a noninvasive technique with high accuracy in anatomical evaluation of the coronary arteries and may be particularly useful to assess the incidence, location and morphology of myocardial bridging in vivo. (author)

  5. Pre-operative high sensitive C-reactive protein predicts cardiovascular events after coronary artery bypass grafting surgery: A prospective observational study

    Directory of Open Access Journals (Sweden)

    Balciunas Mindaugas

    2009-01-01

    Full Text Available C-reactive protein is a powerful independent predictor of cardiovascular events in patients with coronary artery disease. The relation between C-reactive protein (CRP concentration and in-hospital outcome, after coronary artery bypass grafting (CABG, has not yet been established. The study aims to evaluate the predictive value of pre-operative CRP for in-hospital cardiovascular events after CABG surgery. High-sensitivity CRP (hs-CRP levels were measured pre-operatively on the day of surgery in 66 patients scheduled for elective on pump CABG surgery. Post-operative cardiovascular events such as death from cardiovascular causes, ischemic stroke, myocardial damage, myocardial infarction and low output heart failure were recorded. During the first 30 days after surgery, 54 patients were free from observed events and 14 developed the following cardiovascular events: 10 (15% had myocardial damage, four (6% had low output heart failure and two (3% suffered stroke. No patients died during the follow-up period. Serum concentration of hs-CRP ≥ 3.3 mg/l (cut-off point obtained by ROC analysis was related to higher risk of post-operative cardiovascular events (36% vs 6%, P = 0.01, myocardial damage (24% vs 6%, P = 0.04 and low output heart failure (12% vs 0%, P = 0.04. Multivariate logistic regression analysis showed that hs-CRP ≥ 3.3 mg/l ( P = 0.002, O.R.: 19.3 (95% confidence interval (CI 2.9-128.0, intra-operative transfusion of red blood cells ( P = 0.04, O.R.: 9.9 (95% C.I. 1.1-85.5 and absence of diuretics in daily antihypertensive treatment ( P = 0.02, O.R.: 15.1 (95% C.I. 1.4-160.6 were independent predictors of combined cardiovascular event. Patients having hs-CRP value greater or equal to 3.3 mg/l pre-operatively have an increased risk of post-operative cardiovascular events after on pump coronary artery bypass grafting surgery.

  6. Association between diabetes and different components of coronary atherosclerotic plaque burden as measured by coronary multidetector computed tomography.

    Science.gov (United States)

    Yun, Chun-Ho; Schlett, Christopher L; Rogers, Ian S; Truong, Quynh A; Toepker, Michael; Donnelly, Patrick; Brady, Thomas J; Hoffmann, Udo; Bamberg, Fabian

    2009-08-01

    The aim of the study was to assess differences in the presence, extent, and composition of coronary atherosclerotic plaque burden as detected by coronary multidetector computed tomography (MDCT) between patients with and without diabetes mellitus. We compared coronary atherosclerotic plaques (any plaque, calcified [CAP], non-calcified [NCAP, and mixed plaque [MCAP

  7. Imaging diagnosis of congenital heart disease with single coronary artery

    International Nuclear Information System (INIS)

    Zhu Ming; Li Yuhua; Zhong Yumin; Sun Aimin

    2003-01-01

    Objective: To report 56 cases of congenital heart disease with congenital single coronary artery and to evaluate the imaging diagnostic techniques. Methods: All 56 patients with congenital single coronary artery underwent angiocardiography. Contrast enhancement magnetic resonance angiography (CE MRA) was performed in 4 cases. 48 cases were confirmed by operation. Results: In these 56 cases, single left coronary artery was found in 44 cases and single right coronary artery was found in 12. Conclusion: Congenital heart disease with congenital single coronary artery is not rare and correct diagnosis is very important for surgery

  8. Calcified Plaque of Coronary Artery: Factors Influencing Overestimation of Coronary Artery Stenosis on Coronary CT Angiography

    International Nuclear Information System (INIS)

    Kim, Mok Hee; Kim, Yun Hyeon; Choi, Song; Seon, Hyun Ju; Jeong, Gwang Woo; Park, Jin Gyoon; Kang, Heoung Keun; Ko, Joon Seok

    2010-01-01

    To assess the influence of calcified plaque characteristics on the overestimation of coronary arterial stenosis on a coronary CT angiography (CCTA). The study included 271 coronary arteries with calcified plaques identified by CCTA, and based on 928 coronary arteries from 232 patients who underwent both CCTA and invasive coronary angiography (ICA). Individual coronary arteries were classified into two groups by agreement based on the degree of stenosis from each CCTA and ICA: 1) group A includes patients with concordant CCTA and ICA results and, 2) group B includes patients with an overestimation of CCTA compared to ICA. Parameters including total calcium score, calcium score of an individual coronary artery, calcium burden number of an individual coronary artery, and the density of each calcified plaque (calcium score / number of calcium burden) for each individual coronary artery were compared between the two groups. Of the 271 coronary arteries, 164 (60.5%) were overestimated on CCTA. The left anterior descending artery (LAD) had a significantly low rate of overestimation (47.1%) compared to the other coronary arteries (p=0.001). No significant differences for total calcium score, calcium score of individual coronary artery, and the density of each calcified plaque from individual coronary arteries between two groups was observed. However, a decreasing tendency for the rate of overestimation on CCTA was observed with an increase in calcium burden of individual coronary arteries (p<0.05). The evaluation of coronary arteries suggests that the degree of coronary arterial stenosis had a tendency to be overestimated by calcified plaques on CCTA. However, the rate of overestimation for the degree of coronary arterial stenosis by calcified plaques was not significantly influenced by total calcium score, calcium score of individual coronary artery, and density of each calcified plaque

  9. Hemodynamic analysis of sequential graft from right coronary system to left coronary system.

    Science.gov (United States)

    Wang, Wenxin; Mao, Boyan; Wang, Haoran; Geng, Xueying; Zhao, Xi; Zhang, Huixia; Xie, Jinsheng; Zhao, Zhou; Lian, Bo; Liu, Youjun

    2016-12-28

    Sequential and single grafting are two surgical procedures of coronary artery bypass grafting. However, it remains unclear if the sequential graft can be used between the right and left coronary artery system. The purpose of this paper is to clarify the possibility of right coronary artery system anastomosis to left coronary system. A patient-specific 3D model was first reconstructed based on coronary computed tomography angiography (CCTA) images. Two different grafts, the normal multi-graft (Model 1) and the novel multi-graft (Model 2), were then implemented on this patient-specific model using virtual surgery techniques. In Model 1, the single graft was anastomosed to right coronary artery (RCA) and the sequential graft was adopted to anastomose left anterior descending (LAD) and left circumflex artery (LCX). While in Model 2, the single graft was anastomosed to LAD and the sequential graft was adopted to anastomose RCA and LCX. A zero-dimensional/three-dimensional (0D/3D) coupling method was used to realize the multi-scale simulation of both the pre-operative and two post-operative models. Flow rates in the coronary artery and grafts were obtained. The hemodynamic parameters were also showed, including wall shear stress (WSS) and oscillatory shear index (OSI). The area of low WSS and OSI in Model 1 was much less than that in Model 2. Model 1 shows optimistic hemodynamic modifications which may enhance the long-term patency of grafts. The anterior segments of sequential graft have better long-term patency than the posterior segments. With rational spatial position of the heart vessels, the last anastomosis of sequential graft should be connected to the main branch.

  10. Myocardial imaging by direct injection of thallium-201 into coronary artery

    International Nuclear Information System (INIS)

    Sugihara, Hiroki; Inagaki, Suetsugu; Kubota, Yasushi

    1988-01-01

    Myocardial perfusion images were evaluated by direct injection of Thallium (Tl)-201 into coronary artery. Approximately 0.5 - 1 mCi of Tl-201 were instilled into the right coronary artery and/or the left coronary artery after coronary arteriography. Three images were obtained in the anterior, left anterior oblique and left lateral projections. Myocardial perfusion images of single photon emission computed tomography were also acquired in some patients. An image of supreme quality could be obtained in spite of small dose of Tl-201 since there was a lack of interference from background activity. Myocardial perfusion images corresponded to areas which were supplied by left or right coronary artery respectively. And the regional myocardial blood flow distribution of a coronary artery bypass graft could be revealed by instilling Tl-201 into the graft. Further, contribution of collateral channels to myocardial perfusion was showed. Not only left ventricle but also right ventricle was clearly visualized by injection of Tl-201 into right coronary artery. But in a case with arrhythmogenic right ventricular dysplasia, there was an area of decreased tracer uptake in the apex of the right ventricle which was identified as the site of dysplasia by electrophysiologic study. We conclude that direct injection of Tl-201 into coronary artery is an useful method to clarify the correlation between coronary anatomical findings and coronary perfusion and contribution of collaterals to myocardial perfusion, and also to detect the right ventricular myopathic site. (author)

  11. Nanomechanical characterization by double-pass force-distance mapping

    Energy Technology Data Exchange (ETDEWEB)

    Dagdas, Yavuz S; Tekinay, Ayse B; Guler, Mustafa O; Dana, Aykutlu [UNAM Institute of Materials Science and Nanotechnology, Bilkent University, 06800 Ankara (Turkey); Necip Aslan, M, E-mail: aykutlu@unam.bilkent.edu.tr [Department of Physics, Istanbul Technical University, Istanbul (Turkey)

    2011-07-22

    We demonstrate high speed force-distance mapping using a double-pass scheme. The topography is measured in tapping mode in the first pass and this information is used in the second pass to move the tip over the sample. In the second pass, the cantilever dither signal is turned off and the sample is vibrated. Rapid (few kHz frequency) force-distance curves can be recorded with small peak interaction force, and can be processed into an image. Such a double-pass measurement eliminates the need for feedback during force-distance measurements. The method is demonstrated on self-assembled peptidic nanofibers.

  12. Nanomechanical characterization by double-pass force-distance mapping

    International Nuclear Information System (INIS)

    Dagdas, Yavuz S; Tekinay, Ayse B; Guler, Mustafa O; Dana, Aykutlu; Necip Aslan, M

    2011-01-01

    We demonstrate high speed force-distance mapping using a double-pass scheme. The topography is measured in tapping mode in the first pass and this information is used in the second pass to move the tip over the sample. In the second pass, the cantilever dither signal is turned off and the sample is vibrated. Rapid (few kHz frequency) force-distance curves can be recorded with small peak interaction force, and can be processed into an image. Such a double-pass measurement eliminates the need for feedback during force-distance measurements. The method is demonstrated on self-assembled peptidic nanofibers.

  13. Sudden Death Due to Coronary Artery Lesions Long-term After the Arterial Switch Operation: A Systematic Review.

    NARCIS (Netherlands)

    van Wijk, Sebastiaan W.H.; van der Stelt, Femke; ter Heide, Henriëtte; Schoof, Paul H.; Doevendans, Pieter A.F.M.; Meijboom, Folkert J.; Breur, Johannes M.P.J.

    2017-01-01

    Background The arterial switch operation (ASO) is the preferred procedure for children with dextrotransposition of the great arteries or Taussig-Bing anomaly. Short- as well as long-term outcome of ASO are excellent, but coronary artery stenoses are reported as a common long-term complication. It

  14. Gender differences in coronary plaque composition by coronary computed tomography angiography.

    Science.gov (United States)

    Blaha, Michael J; Nasir, Khurram; Rivera, Juan J; Choi, Eue-Keun; Chang, Sung-A; Yoon, Yeonyee E; Chun, Eun Ju; Choi, Sang-il; Agatston, Arthur; Blumenthal, Roger S; Chang, Hyuk-Jae

    2009-12-01

    Coronary computed tomography angiography allows the differentiation of non-calcified (NCAP), calcified (CAP), and mixed coronary artery plaques (MCAP). Although males are thought to have a higher prevalence of atherosclerosis for a given age, there are currently few data regarding age-adjusted sex differences in plaque morphology and composition. We studied 1015 consecutive asymptomatic South Korean patients (49+/-10 years, 64% men) who underwent 64-slice coronary computed tomography angiography during a routine health evaluation. Coronary plaque characteristics were analyzed on a per-segment basis according to the modified AHA classification. Plaques with more than 50% calcified tissue were classified as CAP, plaques with less than 50% calcified tissue were classified as MCAP, and plaques without calcium were classified as NCAP. Multiple regression analysis was used to describe the cross-sectional association between sex and plaque-type burden (>or=2 affected segments) after adjustment for age and other cardiovascular risk factors. There was a greater prevalence of coronary plaque among men (13 vs. 4%, PNCAP was similar across sex (2 vs. 1%, P = 0.28). After multivariable adjustment, men have six to seven times greater odds of having an increased burden of CAP and MCAP, whereas no sex difference was observed in the burden of NCAP. In this population of asymptomatic middle-aged Korean individuals, males had a significantly greater burden of MCAP and CAP. Future studies will determine whether these differences contribute to the accelerated cardiovascular risk observed in men.

  15. Estimation of coronary flow reserve by sestamibi imaging in patients with mild hypertension and normal coronary arteries

    International Nuclear Information System (INIS)

    Storto, G.; Gallicchio, R.; Maddalena, F.; Pellegrino, T.; Petretta, M.; Fiumara, G.; Cuocolo, A.

    2015-01-01

    Patients with hypertension may exhibit abnormal vasodilator capacity during pharmacological vasodilatation. We assessed coronary flow reserve (CFR) by sestamibi imaging in hypertensive patients with normal coronary vessels. Twenty-five patients with untreated mild essential hypertension and normal coronary vessels and 10 control subjects underwent dipyridamole-rest Tc-99m sestamibi imaging. Myocardial blood flow (MBF) was estimated by measuring first transit counts in pulmonary artery and myocardial counts from tomograhic images. CFR was expressed as the ratio of stress to rest MBF. Coronary vascular resistances (CVR) were computed as the ratio between mean arterial pressure and MBF. Estimated MBF at rest was not different in patients and controls (1.11±0.59 vs. 1.14±0.28 counts/pixel/s; P=0.87). Conversely, stress MBF was lower in patients than in controls (1.55±0.47 vs. 2.68±0.53 counts/pixel/s; P<0.001). Thus, CFR was reduced in patients compared to controls (1.61±0.58 vs. 2.43±0.62; P<0.001). Rest and stress CVR values were higher in patients (P<0.001), while stress-induced changes in CVR were not different (P=0.08) between patients (-51%) and controls (-62%). In the overall study population, a significant relation between CFR and stress-induced changes in CVR was observed (r=-0.86; P<0.001). Sestamibi imaging may detect impaired coronary vascular function in response to dipyridamole in patients with untreated mild essential hypertension and normal coronary arteries. A mild increase in arterial blood pressure does not affect baseline MBF, but impairs coronary reserve due to the amplified resting coronary resistances.

  16. Early results of coronary artery bypass grafting with coronary endarterectomy for severe coronary artery disease

    Directory of Open Access Journals (Sweden)

    Toischer Karl

    2009-09-01

    Full Text Available Abstract Background Despite the existence of controversial debates on the efficiency of coronary endarterectomy (CE, it is still used as an adjunct to coronary artery bypass grafting (CABG. This is particularly true in patients with endstage coronary artery disease. Given the improvements in cardiac surgery and postoperative care, as well as the rising number of elderly patient with numerous co-morbidities, re-evaluating the pros and cons of this technique is needed. Methods Patient demographic information, operative details and outcome data of 104 patients with diffuse calcified coronary artery disease were retrospectively analyzed with respect to functional capacity (NYHA, angina pectoris (CCS and mortality. Actuarial survival was reported using a Kaplan-Meyer analysis. Results Between August 2001 and March 2005, 104 patients underwent coronary artery bypass grafting (CABG with adjunctive coronary endarterectomy (CE in the Department of Thoracic-, Cardiac- and Vascular Surgery, University of Goettingen. Four patients were lost during follow-up. Data were gained from 88 male and 12 female patients; mean age was 65.5 ± 9 years. A total of 396 vessels were bypassed (4 ± 0.9 vessels per patient. In 98% left internal thoracic artery (LITA was used as arterial bypass graft and a total of 114 vessels were endarterectomized. CE was performed on right coronary artery (RCA (n = 55, on left anterior descending artery (LAD (n = 52 and circumflex artery (RCX (n = 7. Ninety-five patients suffered from 3-vessel-disease, 3 from 2-vessel- and 2 from 1-vessel-disease. Closed technique was used in 18%, open technique in 79% and in 3% a combination of both. The most frequent endarterectomized localization was right coronary artery (RCA = 55%. Despite the severity of endstage atherosclerosis, hospital mortality was only 5% (n = 5. During follow-up (24.5 ± 13.4 months, which is 96% complete (4 patients were lost caused by unknown address 8 patients died (cardiac

  17. Randomized comparison of operator radiation exposure comparing transradial and transfemoral approach for percutaneous coronary procedures: rationale and design of the minimizing adverse haemorrhagic events by TRansradial access site and systemic implementation of angioX - RAdiation Dose study (RAD-MATRIX).

    Science.gov (United States)

    Sciahbasi, Alessandro; Calabrò, Paolo; Sarandrea, Alessandro; Rigattieri, Stefano; Tomassini, Francesco; Sardella, Gennaro; Zavalloni, Dennis; Cortese, Bernardo; Limbruno, Ugo; Tebaldi, Matteo; Gagnor, Andrea; Rubartelli, Paolo; Zingarelli, Antonio; Valgimigli, Marco

    2014-06-01

    Radiation absorbed by interventional cardiologists is a frequently under-evaluated important issue. Aim is to compare radiation dose absorbed by interventional cardiologists during percutaneous coronary procedures for acute coronary syndromes comparing transradial and transfemoral access. The randomized multicentre MATRIX (Minimizing Adverse Haemorrhagic Events by TRansradial Access Site and Systemic Implementation of angioX) trial has been designed to compare the clinical outcome of patients with acute coronary syndromes treated invasively according to the access site (transfemoral vs. transradial) and to the anticoagulant therapy (bivalirudin vs. heparin). Selected experienced interventional cardiologists involved in this study have been equipped with dedicated thermoluminescent dosimeters to evaluate the radiation dose absorbed during transfemoral or right transradial or left transradial access. For each access we evaluate the radiation dose absorbed at wrist, at thorax and at eye level. Consequently the operator is equipped with three sets (transfemoral, right transradial or left transradial access) of three different dosimeters (wrist, thorax and eye dosimeter). Primary end-point of the study is the procedural radiation dose absorbed by operators at thorax. An important secondary end-point is the procedural radiation dose absorbed by operators comparing the right or left radial approach. Patient randomization is performed according to the MATRIX protocol for the femoral or radial approach. A further randomization for the radial approach is performed to compare right and left transradial access. The RAD-MATRIX study will probably consent to clarify the radiation issue for interventional cardiologist comparing transradial and transfemoral access in the setting of acute coronary syndromes. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Early and long-term outcomes of coronary artery bypass grafting in patients with acute coronary syndrome versus stable angina pectoris.

    Science.gov (United States)

    Fukui, Toshihiro; Tabata, Minoru; Morita, Satoshi; Takanashi, Shuichiro

    2013-06-01

    The aim of the present study was to determine the early and long-term outcomes of coronary artery bypass grafting in patients with acute coronary syndrome and stable angina pectoris. From September 2004 to September 2011, 382 patients with acute coronary syndrome (unstable angina pectoris and non-ST-segment elevation myocardial infarction) and 851 patients with stable angina pectoris underwent first-time isolated coronary artery bypass grafting at our institute. The early and long-term outcomes were compared between the 2 groups. Patients with acute coronary syndrome were older, were more likely to be women, had a smaller body surface area, and were more likely to have left main coronary artery disease. In both groups, bilateral internal thoracic artery grafts were used in approximately 89% of the patients, and off-pump techniques in approximately 97% of the patients. The acute coronary syndrome group had a greater operative death rate (2.6% vs 0.1%) and a greater incidence of low output syndrome (3.1% vs 1.2%) and hemodialysis requirement (2.9% vs 1.1%). Multivariate regression analysis demonstrated that age, acute coronary syndrome, lower ejection fraction, and higher creatinine level before surgery were independent predictors of operative death. However, among the hospital survivors, no differences were seen in freedom from all death (85.4% ± 2.5% vs 87.7% ± 2.0%), cardiac death (97.4% ± 0.9% vs 96.5% ± 0.9%), or major adverse cardiac and cerebrovascular events (78.0% ± 2.9% vs 78.1% ± 2.3%) at 7 years between the patients with acute coronary syndrome and stable angina pectoris. Although acute coronary syndrome is an independent predictor of early mortality in patients undergoing coronary artery bypass grafting, the long-term outcomes after surgery were similar between patients with acute coronary syndrome and stable angina pectoris who survived the early postoperative period. Copyright © 2013 The American Association for Thoracic Surgery. Published by

  19. An experimental evaluation of multi-pass solar air heaters

    Energy Technology Data Exchange (ETDEWEB)

    Satcunanathan, S.; Persad, P.

    1980-12-01

    Three collectors of identical dimensions but operating in the single-pass, two-pass and three-pass modes were tested simultaneously under ambient conditions. It was found that the two-pass air heater was consistently better than the single-pass air heater over the day for the range of mass flow rates considered. It was also found that at a mass flow rate of 0.0095 kg s/sup -1/ m/sup -2/, the thermal performances of the two-pass and three-pass collectors were identical, but at higher flow rates the two-pass collector was superior to the three-pass collector, the superiority decreasing with increasing mass flow rate.

  20. Usefulness of detecting atherosclerosis by computed tomography. A relation to coronary artery stenosis

    International Nuclear Information System (INIS)

    Takasu, Junichiro; Yamamoto, Rie; Yokoyama, Kenichi

    1999-01-01

    Reports evaluating coronary artery calcification detection by nonenhanced computed tomography (CT) have verified the usefulness for diagnosis of coronary artery disease. In the condition of a mobile CT scanning at a public health examination, however, determination of coronary calcification remains unclear. We investigated, under this scanning condition, a relation between the characteristic of coronary artery calcification determined by conventional CT and coronary disease on arteriogram. The quantification of aortic wall thickening by enhanced CT was examined on the usefulness of detecting coronary artery disease. The CT density score and the characteristics of aortic atherosclerosis for 159 male patients 30 year-old or more (average age 60.7 years) were examined the relation to coronary artery stenoses. The CT density score was the strongest independent variable for determining the existence of coronary disease. The CT density cutoff score for detection of coronary disease was 50 equal to 50 HU the maximal CT density in the coronary arteries. The maximal aortic wall thickness was the strongest significant variable independent of the noted coronary risk factors for the severity of coronary stenosis on arteriogram. (author)

  1. Lack of a relationship between serum ferritin levels and coronary atherosclerosis evaluated by coronary arteriography

    Directory of Open Access Journals (Sweden)

    W.C. Manfroi

    1999-03-01

    Full Text Available Many clinical and epidemiological studies have demonstrated the relationship between serum ferritin and ischemic heart disease. In the present study we evaluated the relationship between coronary heart disease (CHD and serum ferritin levels in patients submitted to coronary arteriography. We evaluated 307 patients (210 (68.7% males; median age: 60 years who were submitted to coronary angiography, measurement of serum ferritin and identification of clinical events of ischemic heart disease. Serum ferritin is reported as quartiles. Ninety-six patients (31.27% had normal coronary angiography (group 1 and 211 (68.73% had coronary heart disease (group 2. Of the patients with CHD, 61 (28.9% had serum ferritin levels higher than 194 ng/ml (4th quartile, as opposed to only 14 (14.58% of those without CHD (P = 0.0067. In the 2nd quartile, 39 patients (18.48% had CHD, while 35 patients (36.46% had normal coronary arteries (P = 0.00064. Multivariate analysis of the data showed that the difference between groups was not statistically significant (P = 0.33. We conclude that there is no independent relationship between coronary heart disease and increased levels of serum ferritin.

  2. Fish pass assessment by remote control: a novel framework for quantifying the hydraulics at fish pass entrances

    Science.gov (United States)

    Kriechbaumer, Thomas; Blackburn, Kim; Gill, Andrew; Breckon, Toby; Everard, Nick; Wright, Ros; Rivas Casado, Monica

    2014-05-01

    Fragmentation of aquatic habitats can lead to the extinction of migratory fish species with severe negative consequences at the ecosystem level and thus opposes the target of good ecological status of rivers defined in the EU Water Framework Directive (WFD). In the UK, the implementation of the EU WFD requires investments in fish pass facilities of estimated 532 million GBP (i.e. 639 million Euros) until 2027 to ensure fish passage at around 3,000 barriers considered critical. Hundreds of passes have been installed in the past. However, monitoring studies of fish passes around the world indicate that on average less than half of the fish attempting to pass such facilities are actually successful. There is a need for frameworks that allow the rapid identification of facilities that are biologically effective and those that require enhancement. Although there are many environmental characteristics that can affect fish passage success, past research suggests that variations in hydrodynamic conditions, reflected in water velocities, velocity gradients and turbulences, are the major cues that fish use to seek migration pathways in rivers. This paper presents the first steps taken in the development of a framework for the rapid field-based quantification of the hydraulic conditions downstream of fish passes and the assessment of the attractivity of fish passes for salmonids and coarse fish in UK rivers. For this purpose, a small-sized remote control platform carrying an acoustic Doppler current profiler (ADCP), a GPS unit, a stereo camera and an inertial measurement unit has been developed. The large amount of data on water velocities and depths measured by the ADCP within relatively short time is used to quantify the spatial and temporal distribution of water velocities. By matching these hydraulic features with known preferences of migratory fish, it is attempted to identify likely migration routes and aggregation areas at barriers as well as hydraulic features that

  3. Generalizing Galileo's Passe-Dix Game

    Science.gov (United States)

    Hombas, Vassilios

    2012-01-01

    This article shows a generalization of Galileo's "passe-dix" game. The game was born following one of Galileo's [G. Galileo, "Sopra le Scoperte dei Dadi" (Galileo, Opere, Firenze, Barbera, Vol. 8). Translated by E.H. Thorne, 1898, pp. 591-594] explanations on a paradox that occurred in the experiment of tossing three fair "six-sided" dice.…

  4. Detection of coronary artery calcification by ultrafast CT and correlation with angiography

    International Nuclear Information System (INIS)

    Zhang Shaoxiong; Dai Ruping; Lu Bin

    1997-01-01

    To investigate the relationship between coronary calcification and significant coronary stenosis ninety patients including 81 men and 9 women were studied asithage ranging from 27∼72 years (mean, 58 years). All patients had both ultrafast CT (UFCT) examination and coronary angiography within one month. Single slice mode with ECG gating and thickness of 3 mm were used in UFCT scan. Selected coronary angiography was performed by the Judkins technique. Among 160 vessels in which coronary calcifications were identified, 74% had significant coronary stenosis (>50% stenosis), and 77% of 154 vessels with significant coronary stenosis had calcification demonstrable by UFCT. In the younger age group the sensitivity of calcification for evaluating stenosis of coronary artery was lower and the specificity was generally higher than those in the elderly group. UFCT is a promising procedure for detecting coronary arterial disease, since this examination has high sensitivity and specificity, easy to conduct, noninvasive, and widely applicable for screening a large population

  5. The treatment of malignant ventricular tachycardia by aorto-coronary saphenous vein bypass graft

    Science.gov (United States)

    Ikram, H.; Jeffery, R. M.; Parkins, R. A.; Makey, A. R.; Emery, E. R. J.; Stone, D. L.

    1974-01-01

    A 61-year-old man with a previous cardiac infarction had at least fifteen attacks of ventricular tachycardia which finally did not respond to either drug or electrical therapy. Angiography showed a blocked right coronary artery and a non-contractile portion of postero-inferior left ventricular wall. An aorto to right coronary saphenous vein bypass graft was inserted, and although attacks of tachycardia occurred following the operation these were of short duration and reverted spontaneously. He has been free of tachycardia for 5 weeks, with a greatly improved effort tolerance. ImagesFig. 2Fig. 3

  6. Randomized comparison of operator radiation exposure comparing transradial and transfemoral approach for percutaneous coronary procedures: rationale and design of the minimizing adverse haemorrhagic events by TRansradial access site and systemic implementation of angioX – RAdiation Dose study (RAD-MATRIX)

    International Nuclear Information System (INIS)

    Sciahbasi, Alessandro; Calabrò, Paolo; Sarandrea, Alessandro; Rigattieri, Stefano; Tomassini, Francesco; Sardella, Gennaro; Zavalloni, Dennis; Cortese, Bernardo; Limbruno, Ugo; Tebaldi, Matteo; Gagnor, Andrea; Rubartelli, Paolo; Zingarelli, Antonio; Valgimigli, Marco

    2014-01-01

    Background: Radiation absorbed by interventional cardiologists is a frequently under-evaluated important issue. Aim is to compare radiation dose absorbed by interventional cardiologists during percutaneous coronary procedures for acute coronary syndromes comparing transradial and transfemoral access. Methods: The randomized multicentre MATRIX (Minimizing Adverse Haemorrhagic Events by TRansradial Access Site and Systemic Implementation of angioX) trial has been designed to compare the clinical outcome of patients with acute coronary syndromes treated invasively according to the access site (transfemoral vs. transradial) and to the anticoagulant therapy (bivalirudin vs. heparin). Selected experienced interventional cardiologists involved in this study have been equipped with dedicated thermoluminescent dosimeters to evaluate the radiation dose absorbed during transfemoral or right transradial or left transradial access. For each access we evaluate the radiation dose absorbed at wrist, at thorax and at eye level. Consequently the operator is equipped with three sets (transfemoral, right transradial or left transradial access) of three different dosimeters (wrist, thorax and eye dosimeter). Primary end-point of the study is the procedural radiation dose absorbed by operators at thorax. An important secondary end-point is the procedural radiation dose absorbed by operators comparing the right or left radial approach. Patient randomization is performed according to the MATRIX protocol for the femoral or radial approach. A further randomization for the radial approach is performed to compare right and left transradial access. Conclusions: The RAD-MATRIX study will probably consent to clarify the radiation issue for interventional cardiologist comparing transradial and transfemoral access in the setting of acute coronary syndromes

  7. Randomized comparison of operator radiation exposure comparing transradial and transfemoral approach for percutaneous coronary procedures: rationale and design of the minimizing adverse haemorrhagic events by TRansradial access site and systemic implementation of angioX – RAdiation Dose study (RAD-MATRIX)

    Energy Technology Data Exchange (ETDEWEB)

    Sciahbasi, Alessandro, E-mail: alessandro.sciahbasi@fastwebnet.it [Interventional Cardiology, Sandro Pertini Hospital – ASL RMB, Rome (Italy); Calabrò, Paolo [Division of Cardiology - Department of Cardio-Thoracic Sciences - Second University of Naples (Italy); Sarandrea, Alessandro [HSE Management, Rome (Italy); Rigattieri, Stefano [Interventional Cardiology, Sandro Pertini Hospital – ASL RMB, Rome (Italy); Tomassini, Francesco [Department of Cardiology, Infermi Hospital, Rivoli (Italy); Sardella, Gennaro [La Sapienza University, Rome (Italy); Zavalloni, Dennis [UO Emodinamica e Cardiologia Invasiva, IRCCS, Istituto Clinico Humanitas, Rozzano (Italy); Cortese, Bernardo [Interventional Cardiology, Fatebenefratelli Hospital, Milan (Italy); Limbruno, Ugo [Cardiology Unit, Misericordia Hospital, Grosseto (Italy); Tebaldi, Matteo [Cardiology Department, University of Ferrara, Department of Cardiology (Italy); Gagnor, Andrea [Department of Cardiology, Infermi Hospital, Rivoli (Italy); Rubartelli, Paolo [Villa Scassi Hospital, Genova (Italy); Zingarelli, Antonio [San Martino Hospital, Genova (Italy); Valgimigli, Marco [Thoraxcenter, Rotterdam (Netherlands)

    2014-06-15

    Background: Radiation absorbed by interventional cardiologists is a frequently under-evaluated important issue. Aim is to compare radiation dose absorbed by interventional cardiologists during percutaneous coronary procedures for acute coronary syndromes comparing transradial and transfemoral access. Methods: The randomized multicentre MATRIX (Minimizing Adverse Haemorrhagic Events by TRansradial Access Site and Systemic Implementation of angioX) trial has been designed to compare the clinical outcome of patients with acute coronary syndromes treated invasively according to the access site (transfemoral vs. transradial) and to the anticoagulant therapy (bivalirudin vs. heparin). Selected experienced interventional cardiologists involved in this study have been equipped with dedicated thermoluminescent dosimeters to evaluate the radiation dose absorbed during transfemoral or right transradial or left transradial access. For each access we evaluate the radiation dose absorbed at wrist, at thorax and at eye level. Consequently the operator is equipped with three sets (transfemoral, right transradial or left transradial access) of three different dosimeters (wrist, thorax and eye dosimeter). Primary end-point of the study is the procedural radiation dose absorbed by operators at thorax. An important secondary end-point is the procedural radiation dose absorbed by operators comparing the right or left radial approach. Patient randomization is performed according to the MATRIX protocol for the femoral or radial approach. A further randomization for the radial approach is performed to compare right and left transradial access. Conclusions: The RAD-MATRIX study will probably consent to clarify the radiation issue for interventional cardiologist comparing transradial and transfemoral access in the setting of acute coronary syndromes.

  8. Quality of Life in Patients of Different Age Groups before and after Coronary Artery By-Pass Surgery

    Science.gov (United States)

    Jovanovic-Markovic, Snežana; Peric, Dejan; Rasic, Dragisa; Novakovic, Tatjana; Dejanovic, Bogdan; Borzanovic, Milorad

    2015-01-01

    Purpose: The study evaluates the changes in quality of life (QOL) six months after coronary artery bypass grafting (CABG) related to the patients’ age. Methods: The total of 243 consecutive patients completed the Nottingham Health Profile Questionnaire part 1 before and six months after CABG. Postoperative questionnaire was completed by 226 patients. Patients were divided into four examined groups (<50, 50–59, 60–69 and ≥70 years), according to their age. Results: Six months after CABG, the quality of life in different sections has been significantly improved in most patients.The analysis of the relation between the age and the changes in QOL of patients six months after CABG showed a significant correlation among the patients’ age and the improvement of QOL in the sections of physical mobility (r = 0.18, p = 0.008), social isolation (r = 0.17, p = 0.01) and energy ( r = 0.21, p = 0.002). The most prominent improvement was found in older patients. The age was not an independent predictor of QOL deterioration after CABG. Conclusions: The most noticeable improvement of QOL six months after CABG was found in older patients. Age is not the independent predictor of deterioration of QOL after CABG. PMID:26328597

  9. A Case Report of Coronary Arteriovenous Fistulas with an Unruptured Coronary Artery Aneurysm Successfully Treated by Surgery

    Directory of Open Access Journals (Sweden)

    Nobuhiro Takeuchi

    2012-01-01

    Full Text Available A 58-year-old female with a history of Wolff-Parkinson-White syndrome presented at our institution with palpitations and chest pain. Electrocardiography revealed paroxysmal supraventricular tachycardia with a heart rate of 188 beats/min. Antiarrhythmic drugs were ineffective, and tachycardia was resolved by electrical cardioversion. Transthoracic echocardiography revealed abnormal vessels around the right coronary artery (RCA and pulmonary artery (PA; in addition, we suspected coronary arteriovenous fistula (CAVF. Coronary angiography and coronary computed tomography revealed dilated fistula vessels, with a 1 cm saccular aneurysm around the RCA, originating from the proximal RCA and left anterior descending artery into the main trunk of PA. Therefore, we confirmed the diagnosis of CAVF with an unruptured aneurysm. We surgically ligated and clipped the fistula vessels and resected the aneurysm. The resected aneurysm measured  cm in size. Pathological examination of the resected aneurysm revealed hypertrophic walls comprising proliferating fibroblasts cells thin elastic fibers. Very few atherosclerotic changes manifested in the aneurysm walls. We report the case of a patient with CAVF and an unruptured coronary artery aneurysm who was successfully treated by surgery.

  10. Non-invasive prediction of hemodynamically significant coronary artery stenoses by contrast density difference in coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Hell, Michaela M., E-mail: michaela.hell@uk-erlangen.de [Department of Cardiology, University of Erlangen (Germany); Dey, Damini [Department of Biomedical Sciences, Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Taper Building, Room A238, 8700 Beverly Boulevard, Los Angeles, CA 90048 (United States); Marwan, Mohamed; Achenbach, Stephan; Schmid, Jasmin; Schuhbaeck, Annika [Department of Cardiology, University of Erlangen (Germany)

    2015-08-15

    Highlights: • Overestimation of coronary lesions by coronary computed tomography angiography and subsequent unnecessary invasive coronary angiography and revascularization is a concern. • Differences in plaque characteristics and contrast density difference between hemodynamically significant and non-significant stenoses, as defined by invasive fractional flow reserve, were assessed. • At a threshold of ≥24%, contrast density difference predicted hemodynamically significant lesions with a specificity of 75%, sensitivity of 33%, PPV of 35% and NPV of 73%. • The determination of contrast density difference required less time than transluminal attenuation gradient measurement. - Abstract: Objectives: Coronary computed tomography angiography (CTA) allows the detection of obstructive coronary artery disease. However, its ability to predict the hemodynamic significance of stenoses is limited. We assessed differences in plaque characteristics and contrast density difference between hemodynamically significant and non-significant stenoses, as defined by invasive fractional flow reserve (FFR). Methods: Lesion characteristics of 59 consecutive patients (72 lesions) in whom invasive FFR was performed in at least one coronary artery with moderate to high-grade stenoses in coronary CTA were evaluated by two experienced readers. Coronary CTA data sets were acquired on a second-generation dual-source CT scanner using retrospectively ECG-gated spiral acquisition or prospectively ECG-triggered axial acquisition mode. Plaque volume and composition (non-calcified, calcified), remodeling index as well as contrast density difference (defined as the percentage decline in luminal CT attenuation/cross-sectional area over the lesion) were assessed using a semi-automatic software tool (Autoplaq). Additionally, the transluminal attenuation gradient (defined as the linear regression coefficient between intraluminal CT attenuation and length from the ostium) was determined

  11. Tools for PV (photovoltaic) plant operators: Nowcasting of passing clouds

    International Nuclear Information System (INIS)

    Paulescu, Marius; Badescu, Viorel; Brabec, Marek

    2013-01-01

    The response time of a PV (photovoltaic) plant is very short and its output power follows the abrupt change in solar irradiance level due to alternate shadow by clouds. The sunshine number (SSN) is a Boolean quantity stating whether the sun is covered by clouds or not, thus being an appropriate parameter to predict the occurrence of direct solar radiation at ground level. Various ARIMA (Autoregressive Integrated Moving Average) models for SSN nowcasting are inferred and discussed in this paper. Actinometric and meteorological data measured at 15 s lag during June 2010 in Timisoara (Romania) are used. The forecasting accuracy is studied as a function of season, of the procedure used to obtain a binary time series and of the type of white noise distribution, respectively. It is demonstrated that the ARIMA(0,1,0) model forecasts SSN with the same accuracy as higher order ARIMA models. The forecasting accuracy decreases when the instability of the radiative regime increases. - Highlights: • Nowcasting of passing clouds is modeled by using a 15 s lag database. • ARIMA (Autoregressive Integrated Moving Average) (0,1,0) model is mostly recommended for nowcasting of passing clouds. • Models accuracy increases by increasing the radiative regime stability

  12. Evaluation of coronary artery remodeling in patients with acute coronary syndrome and stable angina by multislice computed tomography

    International Nuclear Information System (INIS)

    Imazeki, Takako; Sato, Yuichi; Inoue, Fumio; Anazawa, Takeo; Tani, Shigemasa; Matsumoto, Naoya; Takayama, Tadateru; Uchiyama, Takahisa; Saito, Satoshi

    2004-01-01

    Multislice computed tomography (MSCT) was used to evaluate coronary artery remodeling in patients with acute coronary syndrome (ACS) and stable angina (SA). MSCT was performed in 31 patients with ACS and 26 patients with SA and intravascular ultrasound (IVUS) was performed in 28 of these 57 patients. In both the MSCT and IVUS analyses, coronary artery remodeling was assessed by the remodeling index (RI): RI>1.10 was defined as positive coronary artery remodeling (PCAR) and RI<0.95 was defined as negative coronary artery remodeling (NCAR). The RI assessed by MSCT closely correlated with that of IVUS (r=0.86, n=28). The vessel area at the region of maximum luminal narrowing was also comparable between the MSCT and IVUS measurements (r=0.92). PCAR was present in 19 patients (61.3%) with ACS, but in none of the patients with SA (p<0.0001). However, NCAR was present in only 1 patient with ACS (3.2%), but was present in 18 patients (62.9%) with SA. The RI was significantly larger in patients with ACS (1.19±0.18) than in those with SA (0.89±0.10, p<0.0001). MSCT accurately assesses coronary artery remodeling. (author)

  13. Evaluation of coronary artery disease by helical CT using retrospective ECG-gating

    International Nuclear Information System (INIS)

    Kawawa, Yoko

    2001-01-01

    The purpose of this study is to evaluate the usefulness of helical CT using retrospective ECG-gating for visualization of the coronary artery and detection of coronary artery disease. We performed a coronary artery phantom study and established this new application, with 1-mm collimation, 1-mm table increment, and 0.1-mm reconstruction (0.8 sec/rotation). Helical CT of 31 patients with 39 coronary artery diseases (34 coronary artery stenoses, 1 vasospastic angina, 1 coronary artery dissection, 1 coronary artery ectasia and 2 coronary artery aneurysms) was performed in a single breath hold and ECG-gating without and with intravenous injection of nonionic iodine contrast material. We selected the images which were not affected by cardiac motion from the reconstruction images, in order to visualize the coronary artery for detection of coronary artery disease. The coronary artery was well visualized in 32 out of 39 vessels (82%). A good visualization of the coronary artery was correlated with the heart rate. Further, in this well visualized group, coronary artery diseases were detected in 24 out of 31 cases (77%). One case of vasospastic angina was not included. It was difficult to detect coronary artery disease in cases of heavily calcified vessels or in the left circumflex artery. Helical CT using this retrospective ECG-gating is a useful noninvasive examination for evaluation of coronary artery disease. (author)

  14. Evaluation by multislice computed tomography of atherosclerotic coronary artery plaques in non-culprit, remote coronary arteries of patients with acute coronary syndrome

    International Nuclear Information System (INIS)

    Kunimasa, Taeko; Sugi, Kaoru; Moroi, Masao; Sato, Yuichi

    2005-01-01

    Patients with acute coronary syndrome (ACS) frequently have vulnerable plaques in the remote coronary arteries, suggesting that ACS is part of the pan-coronary process. In the present study the computed tomography (CT) plaque density in non-culprit atherosclerotic coronary artery lesions was evaluated by multi-slice computed tomography (MSCT) in patients with ACS and non-ACS. MSCT was performed in 21 patients with ACS and 53 patients with non-ACS: 16 of the 21 ACS patients (76%) and 30 of the non-ACS 53 patients (57%) had non-calcified plaques in the non-culprit coronary arteries (p=0.18). CT-low-density plaques (CT density <68 Hounsfield units (HU)) were more frequent in the ACS group (13/16 patients, 81%) than in the non-ACS group (13/30 patients, 43%, p=0.03). In addition, the CT density of the non-culprit lesion was significantly lower in patients with ACS than in those with non-ACS (44.1±22.9 and 77.3±33.7 HU, respectively). Patients with ACS more frequently had CT-low-density plaques in the non-culprit, remote arteries than those with non-ACS, which suggests that ACS treatment should focus not only on stabilizing the culprit lesion but also on systemic stabilization of non-culprit lesions. (author)

  15. Left coronary arterial blood flow: Noninvasive detection by Doppler US

    International Nuclear Information System (INIS)

    Gramiak, R.; Holen, J.; Moss, A.J.; Gutierrez, O.H.; Picone, A.L.; Roe, S.A.

    1986-01-01

    Continuous wave (CW) and pulsed Doppler ultrasound studies with spectral analysis were used to detect the left coronary arterial blood flow in patients who were undergoing routine echocardiography. The pulmonary artery is a stable ultrasonic landmark from which detection of the blood flow can be effected. The left coronary artery can be distinguished by its blood flow toward the cardiac apex and by specific, functional flow features. Flow patterns vary among the left main, circumflex, and anterior descending arteries; patterns also vary with respiration cycles. In the present study, coronary arterial blood flow was detected in 58 of 70 patients (83%). Findings were validated by selectively injecting an agitated saline contrast medium into the left coronary artery and, in another study, by comparing human Doppler phasic flow waveforms with electromagnetic flowmeter recordings obtained in dogs

  16. Exercise training decreases store-operated Ca2+entry associated with metabolic syndrome and coronary atherosclerosis.

    Science.gov (United States)

    Edwards, Jason M; Neeb, Zachary P; Alloosh, Mouhamad A; Long, Xin; Bratz, Ian N; Peller, Cassandra R; Byrd, James P; Kumar, Sanjay; Obukhov, Alexander G; Sturek, Michael

    2010-02-01

    Stenting attenuates restenosis, but accelerated coronary artery disease (CAD) adjacent to the stent (peri-stent CAD) remains a concern in metabolic syndrome (MetS). Smooth muscle cell proliferation, a major mechanism of CAD, is mediated partly by myoplasmic Ca2+ dysregulation and store-operated Ca2+ entry (SOCE) via canonical transient receptor potential 1 (TRPC1) channels is proposed to play a key role. Exercise is known to prevent Ca2+ dysregulation in CAD. We tested the hypothesis that MetS increases SOCE and peri-stent CAD and exercise attenuates these events. Groups (n = 9 pigs each) were (i) healthy lean Ossabaw swine fed standard chow, (ii) excess calorie atherogenic diet fed (MetS), and (iii) aerobically exercise trained starting after 50 weeks of development of MetS (XMetS). Bare metal stents were placed after 54 weeks on diets, and CAD and SOCE were assessed 4 weeks later. Coronary cells were dispersed proximal to the stent (peri-stent) and from non-stent segments, and fura-2 fluorescence was used to assess SOCE, which was verified by Ni2+ blockade and insensitivity to nifedipine. XMetS pigs had increased physical work capacity and decreased LDL/HDL (P molecular expression of TRPC1, STIM1, and Orai1 in MetS.

  17. Congenital heart disease with high origin of coronary artery

    International Nuclear Information System (INIS)

    Zhu Ming; Li Yuhua; Zhong Yumin

    2002-01-01

    Objective: To report 6 cases of congenital heart disease with high origin of coronary artery and to evaluate the imaging method for diagnosis of congenital high origin of coronary artery. Methods: Six patients with congenital high origin of coronary artery underwent angiocardiography, echocardiography, and 2 patients also underwent magnetic resonance examination. All 6 cases were confirmed by operation. Results: All 6 cases were congenital high origin of right coronary artery. Angiocardiography made correct diagnosis in all 6 cases; MRI made the correct diagnosis in 1 of the 2 cases; echocardiography made 1 correct diagnosis. Conclusion: Correct diagnosis of congenital high origin of coronary artery was very important for patients with congenital heart disease. Angiocardiography was a very reliable imaging method and MRI can play an important role in preoperative diagnosis of congenital high origin of coronary artery

  18. Comparison of traditional cardiovascular risk models and coronary atherosclerotic plaque as detected by computed tomography for prediction of acute coronary syndrome in patients with acute chest pain.

    Science.gov (United States)

    Ferencik, Maros; Schlett, Christopher L; Bamberg, Fabian; Truong, Quynh A; Nichols, John H; Pena, Antonio J; Shapiro, Michael D; Rogers, Ian S; Seneviratne, Sujith; Parry, Blair Alden; Cury, Ricardo C; Brady, Thomas J; Brown, David F; Nagurney, John T; Hoffmann, Udo

    2012-08-01

    The objective was to determine the association of four clinical risk scores and coronary plaque burden as detected by computed tomography (CT) with the outcome of acute coronary syndrome (ACS) in patients with acute chest pain. The hypothesis was that the combination of risk scores and plaque burden improved the discriminatory capacity for the diagnosis of ACS. The study was a subanalysis of the Rule Out Myocardial Infarction Using Computer-Assisted Tomography (ROMICAT) trial-a prospective observational cohort study. The authors enrolled patients presenting to the emergency department (ED) with a chief complaint of acute chest pain, inconclusive initial evaluation (negative biomarkers, nondiagnostic electrocardiogram [ECG]), and no history of coronary artery disease (CAD). Patients underwent contrast-enhanced 64-multidetector-row cardiac CT and received standard clinical care (serial ECG, cardiac biomarkers, and subsequent diagnostic testing, such as exercise treadmill testing, nuclear stress perfusion imaging, and/or invasive coronary angiography), as deemed clinically appropriate. The clinical providers were blinded to CT results. The chest pain score was calculated and the results were dichotomized to ≥10 (high-risk) and modeling was performed to examine the association of risk scores and coronary plaque burden to the outcome of ACS. Unadjusted models were individually fitted for the coronary plaque burden and for Goldman, Sanchis, TIMI, and chest pain scores. In adjusted analyses, the authors tested whether the association between risk scores and ACS persisted after controlling for the coronary plaque burden. The prognostic discriminatory capacity of the risk scores and plaque burden for ACS was assessed using c-statistics. The differences in area under the receiver-operating characteristic curve (AUC) and c-statistics were tested by performing the -2 log likelihood ratio test of nested models. A p value capacity for the diagnosis of ACS. Plaque burden was

  19. Acute Heart Failure Triggered by Coronary Spasm With Transient Left Ventricular Dysfunction.

    Science.gov (United States)

    Adachi, Yusuke; Sakakura, Kenichi; Ibe, Tatsuro; Yoshida, Nanae; Wada, Hiroshi; Fujita, Hideo; Momomura, Shin-Ichi

    2017-04-06

    Coronary spasm is abnormal contraction of an epicardial coronary artery resulting in myocardial ischemia. Coronary spasm induces not only depressed myocardial contractility, but also incomplete myocardial relaxation, which leads to elevated ventricular filling pressure. We herein report the case of a 55-year-old woman who had repeated acute heart failure caused by coronary spasm. Acetylcholine provocation test with simultaneous right heart catheterization was useful for the diagnosis of elevated ventricular filling pressure as well as coronary artery spasm. We should add coronary spasm to a differential diagnosis for repeated acute heart failure.

  20. Role of coronary endothelium in cyclic AMP formation by the heart

    International Nuclear Information System (INIS)

    Kroll, K.; Schrader, J.

    1986-01-01

    In order to quantify the activation of adenylate cyclase of the coronary endothelium in vivo, endothelial adenine nucleotides of isolated guinea pig hearts were selectively pre-labeled by intracoronary infusion of tritiated (H3)-adenosine, and the coronary efflux of H3-cAMP was measured. The adenosine receptor agonist, NECA (12 μM), increased total cAMP release 4 fold, and raised H3-cAMP release 22 fold. Several classes of coronary vasodilators (adenosine, L-PIA, D-PIA, the beta 2-adrenergic agonist procaterol, and PGE1) caused dose-dependent increases in endothelial-derived H3-cAMP release. These increases were accompanied by decreases in vascular resistance, at agonist doses without positive intropic effects. Hypoxic perfusion also raised H3-cAMP release, and this was antagonized by theophylline. It is concluded: (1) cyclic AMP formation by coronary endothelium can dominate total cAMP production by the heart; (2) coronary endothelial adenylate cyclase-coupled receptors for adenosine (A2), catecholamines (beta2) and prostaglandins are activated in parallel with coronary vasodilation; (3) endothelial adenylate cyclase can be activated by endogenous adenosine

  1. A First-Order One-Pass CPS Transformation

    DEFF Research Database (Denmark)

    Danvy, Olivier; Nielsen, Lasse Reichstein

    2001-01-01

    We present a new transformation of λ-terms into continuation-passing style (CPS). This transformation operates in one pass and is both compositional and first-order. Previous CPS transformations only enjoyed two out of the three properties of being first-order, one-pass, and compositional......, but the new transformation enjoys all three properties. It is proved correct directly by structural induction over source terms instead of indirectly with a colon translation, as in Plotkin's original proof. Similarly, it makes it possible to reason about CPS-transformed terms by structural induction over...... source terms, directly.The new CPS transformation connects separately published approaches to the CPS transformation. It has already been used to state a new and simpler correctness proof of a direct-style transformation, and to develop a new and simpler CPS transformation of control-flow information....

  2. A First-Order One-Pass CPS Transformation

    DEFF Research Database (Denmark)

    Danvy, Olivier; Nielsen, Lasse Reichstein

    2003-01-01

    We present a new transformation of λ-terms into continuation-passing style (CPS). This transformation operates in one pass and is both compositional and first-order. Previous CPS transformations only enjoyed two out of the three properties of being first-order, one-pass, and compositional......, but the new transformation enjoys all three properties. It is proved correct directly by structural induction over source terms instead of indirectly with a colon translation, as in Plotkin's original proof. Similarly, it makes it possible to reason about CPS-transformed terms by structural induction over...... source terms, directly.The new CPS transformation connects separately published approaches to the CPS transformation. It has already been used to state a new and simpler correctness proof of a direct-style transformation, and to develop a new and simpler CPS transformation of control-flow information....

  3. Operating characteristics of a qualitative troponin assay for the diagnosis of acute coronary syndrome.

    Science.gov (United States)

    Farsi, Davood; Pishbin, Elham; Abbasi, Saeed; Hafezimoghadam, Peyman; Fathi, Marzieh; Zare, Mohammad Amin

    2013-04-01

    The troponin I serum level is widely used in acute coronary syndrome patients for their classification. The qualitative assay is faster and more available than the quantitative assay. The objective was to determine the operating characteristics of a qualitative troponin I assay compared with a quantitative method. This is a prospective observational study and patients suspected to have acute coronary syndrome were enrolled. A rapid troponin I test and a quantitative assay were carried out for each patient on arrival and 6 h after admission. A total of 262 patients were enrolled. The degree of agreement between the second rapid qualitative and quantitative troponin I was excellent (κ=0.946; 95% confidence interval, 0.903-0.989). The sensitivity, specificity, negative predictive value, and positive predictive value of the rapid qualitative troponin I test were 92.6, 100, 96.8, and 100%, respectively. In conclusion, this study reveals an excellent agreement between quantitative and qualitative bedside assays 6 h after admission in a sample of Iranian patients in the emergency department.

  4. Statistics of Epidemics in Networks by Passing Messages

    Science.gov (United States)

    Shrestha, Munik Kumar

    Epidemic processes are common out-of-equilibrium phenomena of broad interdisciplinary interest. In this thesis, we show how message-passing approach can be a helpful tool for simulating epidemic models in disordered medium like networks, and in particular for estimating the probability that a given node will become infectious at a particular time. The sort of dynamics we consider are stochastic, where randomness can arise from the stochastic events or from the randomness of network structures. As in belief propagation, variables or messages in message-passing approach are defined on the directed edges of a network. However, unlike belief propagation, where the posterior distributions are updated according to Bayes' rule, in message-passing approach we write differential equations for the messages over time. It takes correlations between neighboring nodes into account while preventing causal signals from backtracking to their immediate source, and thus avoids "echo chamber effects" where a pair of adjacent nodes each amplify the probability that the other is infectious. In our first results, we develop a message-passing approach to threshold models of behavior popular in sociology. These are models, first proposed by Granovetter, where individuals have to hear about a trend or behavior from some number of neighbors before adopting it themselves. In thermodynamic limit of large random networks, we provide an exact analytic scheme while calculating the time dependence of the probabilities and thus learning about the whole dynamics of bootstrap percolation, which is a simple model known in statistical physics for exhibiting discontinuous phase transition. As an application, we apply a similar model to financial networks, studying when bankruptcies spread due to the sudden devaluation of shared assets in overlapping portfolios. We predict that although diversification may be good for individual institutions, it can create dangerous systemic effects, and as a result

  5. Long-term results of a randomized controlled trial analyzing the role of systematic pre-operative coronary angiography before elective carotid endarterectomy in patients with asymptomatic coronary artery disease.

    Science.gov (United States)

    Illuminati, G; Schneider, F; Greco, C; Mangieri, E; Schiariti, M; Tanzilli, G; Barillà, F; Paravati, V; Pizzardi, G; Calio', F; Miraldi, F; Macrina, F; Totaro, M; Greco, E; Mazzesi, G; Tritapepe, L; Toscano, M; Vietri, F; Meyer, N; Ricco, J-B

    2015-04-01

    To evaluate the potential benefit of systematic preoperative coronary-artery angiography followed by selective coronary-artery revascularization on the incidence of myocardial infarction (MI) in patients undergoing carotid endarterectomy (CEA) without a previous history of coronary artery disease (CAD). We randomised 426 patients who were candidates for CEA, with no history of CAD, a normal electrocardiogram (ECG), and a normal cardiac ultrasound. In group A (n = 216) all patients underwent coronary angiography before CEA. In group B (n = 210) CEA was performed without coronary angiography. Patients were not blinded for relevant assessments during follow-up. Primary end-point was the occurrence of MI at 3.5 years. The secondary end-point was the overall survival rate. Median length of follow-up was 6.2 years. In group A, coronary angiography revealed significant coronary artery stenosis in 68 patients (31.5%). Among them, 66 underwent percutaneous Intervention (PCI) prior to CEA and 2 received combined CEA and coronary-artery bypass grafting (CABG). Postoperatively, no MI was observed in group A, whereas 6 MI occurred in group B, one of which was fatal (p = .01). During the study period, 3 MI occurred in group A (1.4%) and 33 were observed in group B (15.7%), 6 of which were fatal. The Cox model demonstrated a reduced risk of MI for patients in group A receiving coronary angiography (HR,.078; 95% CI, 0.024-0.256; p < .001). In addition, patients with diabetes and patients <70 years presented with an increased risk of MI. Survival analysis at 6 years by Kaplan-Meier estimates was 95.6 ± 3.2% in Group A and 89.7 ± 3.7% in group B (Log Rank = 6.54, p = .01). In asymptomatic coronary-artery patients, systematic coronary angiography prior to CEA followed by selective PCI or CABG significantly reduces the incidence of late MI and increases long-term survival. (ClinicalTrials.gov number, NCT02260453). Copyright © 2015 European Society for Vascular

  6. Coronary angioplasty with second generation Monorail catheters.

    Science.gov (United States)

    Pande, A K; Meier, B; Urban, P; Villavicencio, R; de la Serna, F; Moles, V

    1991-07-01

    The Monorail system (Schneider) consists of a balloon catheter in which the guidewire passes through the balloon itself, exits the catheter proximal to the balloon, and runs alongside its small shaft (3 French) through the length of the guiding catheter. It offers distinct advantages over conventional systems of coronary angioplasty. It facilitates contrast injections and permits rapid balloon exchanges. This system was used for coronary angioplasty in 273 unselected consecutive patients (age 59 +/- 10, mean 35 to 73 years). There were 216 patients (84%) undergoing single-vessel and 57 patients (16%) with multi-vessel coronary angioplasty. A total of 335 coronary stenoses were dilated, which included 35 total occlusions. The size of balloon used ranged from 2.0 to 4.25 mm (3.0 +/- 0.5 mm) and the severity of stenosis was 85 +/- 11%. Technical success was defined as a residual stenosis of less than 50% as determined angiographically. Clinical success was defined as technical success, and absence of a major inhospital complication defined as absence of myocardial infarction, lack of need for coronary arterial bypass surgery, and survival. The Monorail system was technically successful in 294/300 stenotic lesions (98%). It was clinically successful for 281 lesions (94%). Of the 35 total occlusions, technical success was obtained in 25 (71%). The residual stenosis of successful cases was 26 +/- 21%. The Monorail system was also successful in 5 patients with stenosis of more than 90% in whom conventional systems failed. The complications included acute occlusion causing acute myocardial infarction in 13 cases (5%), emergency coronary arterial bypass surgery in 1 patient (0.4%), and death in 4 patients (1.5%).(ABSTRACT TRUNCATED AT 250 WORDS)

  7. Successful percutaneous coronary intervention significantly improves coronary sinus blood flow as assessed by transthoracic echocardiography.

    Science.gov (United States)

    Lyubarova, Radmila; Boden, William E; Fein, Steven A; Schulman-Marcus, Joshua; Torosoff, Mikhail

    2018-06-01

    Transthoracic echocardiography (TTE) has been used to assess coronary sinus blood flow (CSBF), which reflects total coronary arterial blood flow. Successful angioplasty is expected to improve coronary arterial blood flow. Changes in CSBF after percutaneous coronary intervention (PCI), as assessed by TTE, have not been systematically evaluated. TTE can be utilized to reflect increased CSBF after a successful, clinically indicated PCI. The study cohort included 31 patients (18 females, 62 ± 11 years old) referred for diagnostic cardiac catheterization for suspected coronary artery disease and possible PCI, when clinically indicated. All performed PCIs were successful, with good angiographic outcome. CSBF per cardiac cycle (mL/beat) was measured using transthoracic two-dimensional and Doppler flow imaging as the product of coronary sinus (CS) area and CS flow time-velocity integral. CSBF per minute (mL/min) was calculated as the product of heart rate and CSBF per cardiac cycle. In each patient, CSBF was assessed prospectively, before and after cardiac catheterization with and without clinically indicated PCI. Within- and between-group differences in CSBF before and after PCI were assessed using repeated measures analysis of variance. Technically adequate CSBF measurements were obtained in 24 patients (77%). In patients who did not undergo PCI, there was no significant change in CSBF (278.1 ± 344.1 versus 342.7 ± 248.5, p = 0.36). By contrast, among patients who underwent PCI, CSBF increased significantly (254.3 ± 194.7 versus 618.3 ± 358.5 mL/min, p < 0.01, p-interaction = 0.03). Other hemodynamic and echocardiographic parameters did not change significantly before and after cardiac catheterization in either treatment group. Transthoracic echocardiographic assessment can be employed to document CSBF changes after angioplasty. Future studies are needed to explore the clinical utility of this noninvasive metric.

  8. [Management of coronary artery disease in diabetic patients with lower limb critical ischaemia: assessment of operational risk, drug therapy and indications for interventions].

    Science.gov (United States)

    Dedov, I I; Kalashnikov, V Iu; Terekhin, S A; Melkozerov, K V

    2012-01-01

    Despite obvious progress in management of diabetes mellitus, the DM-related complications rate remains inadmissibly high. Macroangiopathy is known to rank first amongst complications of diabetes mellitus, and coronary artery disease remains to be the major cause of death. Analysed herein are peculiarities of the clinical course in diabetic patients presenting with coronary artery disease and lower limb critical ischaemia, followed by discussing the issues concerning drug therapy, preoperative examination, and methods of diagnosis in this cohort of patients prior to vascular operations, assessment of the preoperative risk, indications for coronarography and myocardial revascularization. Also presented are the results of the main clinical trials dedicated to preoperative myocardial revascularization, including those in diabetic patients with limb critical ischaemia, and finally highlighting current importance of optimizing approaches to managing and working out algorithms of treatment policy for diabetic patients with a combination of coronary artery disease, diabetes mellitus, and critical limb ischaemia.

  9. High-resolution coronary MR angiography for evaluation of patients with anomalous coronary arteries: visualization of the intramural segment

    Energy Technology Data Exchange (ETDEWEB)

    Biko, David M. [UCSF Benioff Children' s Hospital Oakland, Department of Diagnostic Imaging, Oakland, CA (United States); The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Chung, Claudia; Chung, Taylor [UCSF Benioff Children' s Hospital Oakland, Department of Diagnostic Imaging, Oakland, CA (United States); Hitt, David M. [Philips Healthcare, Cleveland, OH (United States); Kurio, Gregory [UCSF Benioff Children' s Hospital Oakland, Department of Cardiology, Oakland, CA (United States); Reinhartz, Olaf [UCSF Benioff Children' s Hospital Oakland, Department of Cardiac Surgery, Oakland, CA (United States)

    2015-08-15

    Anomalous origin of the coronary artery from the contralateral coronary sinus is a rare coronary anomaly associated with sudden death. The inter-arterial course is most closely associated with sudden death, but it has been suggested that the presence of an intramural segment of a right anomalous coronary is associated with more symptoms and therefore may be an important criterion for intervention in these patients. To demonstrate that MR angiography can accurately determine the presence or absence of an intramural segment in an anomalous coronary artery. All studies of children who underwent MR angiography for the evaluation of an anomalous coronary artery were retrospectively reviewed by two pediatric radiologists in consensus. Criteria for an intramural anomalous coronary artery were the presence of a small or slit-like ostium and the relative smaller size of the proximal intramural portion of the coronary artery in relation to the more distal epicardial coronary artery. The anomalous coronary artery was classified as not intramural if these two findings were absent. These findings were correlated with operative reports confirming the presence or absence of an intramural segment. Twelve patients (86%) met MR angiography criteria for the presence of an intramural course. Only 2 patients (14%) met MR angiography criteria for a non-intramural course. When correlating with intraoperative findings, MR angiography was successful in distinguishing between intramural and non-intramural anomalous coronary arteries in all cases (P = 0.01). MR angiography may be able to reliably identify the intramural segment of an anomalous coronary artery in older children using the imaging criteria of a small or slit-like ostium and relative decrease in size of the proximal portion of the anomalous coronary artery compared to the distal portion of the anomalous coronary artery. Determining the presence of the intramural segment may help with surgical planning and may be an important

  10. Combined evaluation of regional coronary artery calcium and myocardial perfusion by {sup 82}Rb PET/CT in the identification of obstructive coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Zampella, Emilia; Assante, Roberta; Nappi, Carmela; Mainolfi, Ciro Gabriele; Green, Roberta; Cantoni, Valeria; Klain, Michele; Cuocolo, Alberto [University Federico II, Department of Advanced Biomedical Sciences, Naples (Italy); Acampa, Wanda [University Federico II, Department of Advanced Biomedical Sciences, Naples (Italy); National Council of Research, Institute of Biostructure and Bioimaging, Naples (Italy); Gaudieri, Valeria; Panico, Mariarosaria [National Council of Research, Institute of Biostructure and Bioimaging, Naples (Italy); Petretta, Mario [University Federico II, Department of Translational Medical Sciences, Naples (Italy); Slomka, Piotr J. [Cedars-Sinai Medical Center, Department of Medicine, Los Angeles, CA (United States); UCLA, David Geffen School of Medicine, Los Angeles, CA (United States)

    2018-04-15

    Cardiac imaging with PET/CT allows measurement of coronary artery calcium (CAC), myocardial perfusion and coronary vascular function. We investigated whether the combined assessment of regional CAC score, ischemic total perfusion deficit (ITPD) and quantitative coronary vascular function would further improve the diagnostic accuracy of PET/CT in predicting obstructive coronary artery disease (CAD). We analyzed 113 patients with suspected CAD referred to {sup 82}Rb PET/CT myocardial perfusion imaging with available coronary angiographic data. Obstructive CAD was defined as ≥75% stenosis. The receiver operating characteristic area under curve (AUC) was applied to evaluate the ability of CAC score, ITPD, hyperemic myocardial blood flow (MBF) and coronary flow reserve (CFR) to identify CAD. Vessels with obstructive CAD (71 vessels) had higher ITPD (4.6 ± 6.2 vs. 0.6 ± 1.3) and lower hyperemic MBF (1.01 ± 0.5 vs. 1.75 ± 0.6 ml/min/g) and CFR (1.56 ± 0.6 vs. 2.38 ± 0.7; all p < 0.001) than those without. In prediction of per-vessel CAD, the AUCs for the models including CAC/ITPD/hyperemic MBF (0.869) and CAC/ITPD/CFR (0.875) were higher (both p < 0.01) than for the model including CAC/ITPD (0.790). Compared with CAC/ITPD, continuous net reclassification improvement was 0.69 (95% bootstrap confidence interval, CI, 0.365-1.088) for the CAC/ITPD/hyperemic MBF model and 0.99 (95% bootstrap CI 0.64-1.26) for the CAC/ITPD/CFR model. Hyperemic MBF and CFR provide incremental information about the presence of CAD over CAC score and perfusion imaging parameters. The combined use of CAC, myocardial perfusion imaging and quantitative coronary vascular function in may help predict more accurately the presence of obstructive CAD. (orig.)

  11. Comparative cath-lab assessment of coronary stenosis by radiology technician, junior and senior interventional cardiologist in patients treated with coronary angioplasty.

    Science.gov (United States)

    Brunetti, Natale Daniele; Delli Carri, Felice; Ruggiero, Maria Assunta; Cuculo, Andrea; Ruggiero, Antonio; Ziccardi, Luigi; De Gennaro, Luisa; Di Biase, Matteo

    2014-03-01

    Exact quantification of plaque extension during coronary angioplasty (PCI) usually falls on interventional cardiologist (IC). Quantitative coronary stenosis assessment (QCA) may be possibly committed to the radiology technician (RT), who usually supports cath-lab nurse and IC during PCI. We therefore sought to investigate the reliability of QCA performed by RT in comparison with IC. Forty-four consecutive patients with acute coronary syndrome underwent PCI; target coronary vessel size beneath target coronary lesion (S) and target coronary lesion length (L) were assessed by the RT, junior IC (JIC), and senior IC (SIC) and then compared. SIC evaluation, which determined the final stent selection for coronary stenting, was considered as a reference benchmark. RT performance with QCA support in assessing target vessel size and target lesion length was not significantly different from SIC (r = 0.46, p < 0.01; r = 0.64, p < 0.001, respectively) as well as JIC (r = 0.79, r = 0.75, p < 0.001, respectively). JIC performance was significantly better than RT in assessing target vessel size (p < 0.05), while not significant when assessing target lesion length. RT may reliably assess target lesion by using adequate QCA software in the cath-lab in case of PCI; RT performance does not differ from SIC.

  12. Collateral Function in Patients with Coronary Occlusion Evaluated by 201Thallium Scintigraphy

    Directory of Open Access Journals (Sweden)

    Aida Hasanović

    2008-11-01

    Full Text Available The present study evaluated the impact of the angiographically documented collaterals on regional myocardial perfusion measured by 201thallium scintigraphy in patients with a chronic total occlusion.The study included 60 patients with chronic total occlusion who underwent rest-stress myocardial perfusion scintigraphy and coronary angiography. All patients had angiographic evidence of coronary collaterals. Patients were divided into two groups: group one had well-developed coronary collateral vessels (n=35 and group II had poor coronary collateral development (n=25.Patients with chronic total occlusion had severe and extensive stress-induced myocardial perfusion defects regardless of the grade of angiographic coronary collaterals. The perfusion defects in the group with good collaterals were predominantly reversible, suggesting that coronary collaterals preserved myocardial viability in the regions subtended by a total coronary occlusion. A significant correlation between good collaterals with complete protection and poor collaterals with no protection was noted.Our results demonstrate a protective effect of collaterals on myocardial perfusion during coronary occlusion. The effective angiographic collaterals may prevent resting regional wall motion abnormalities but do not appear to protect against stress-induced perfusion defect.

  13. Revascularização da artéria coronária direita intra-atrial Revascularization of intracavitary right coronary artery

    Directory of Open Access Journals (Sweden)

    Artur Lourenção Júnior

    1990-12-01

    Full Text Available A artéria coronária direita, em seu trajeto no sulco atrioventricular direito, pode, em raras ocasiões, penetrar na cavidade atrial direita. Esta variação anatômica poderá modificar a tática cirúrgica em operações de revascularização miocárdica. No presente trabalho, relatamos o caso em que a ponte de veia safena para a artéria coronária direita foi realizada em posição intra-atrial direita.The right coronary artery, during your course in the right atrioventricular sulcus, can sometimes penetrate the right atrial cavity. This anatomical variety can modify the surgical tactics in aortocoronary by-pass surgery. In this paper we present a patient in whom the by-pass with saphenous vein graft to the right coronary artery was made in right intracavitary position.

  14. Potential and limitations of radionuclide-based exercise testing before and after operation in the patient with coronary artery disease

    International Nuclear Information System (INIS)

    Borer, J.S.; Phillips, P.; Jacobstein, J.

    1982-01-01

    The authors assess the potential benefits and limitations of radionuclide cineangiography when used to select patients with ischemic heart disease for operation, to precisely plan the operation, and to assess the effects of such therapy. The results indicate that this technique provides potentially important benefits, but also several limitations. Additional studies are required to clarify the optimal role for this technique in the evaluation of the patient with coronary artery disease. (Auth.)

  15. Efficacy of RADPAD protective drape during coronary angiography.

    Science.gov (United States)

    Kherad, B; Jerichow, T; Blaschke, F; Noutsias, M; Pieske, B; Tschöpe, C; Krackhardt, F

    2018-06-01

    Ionizing radiation is an integral part of percutaneous coronary angiographies. Chronic exposure to low-dose radiation confers a risk for skin damage, eye lens opacities or cataracts, and malignant diseases to staff in the catheter laboratory. The RADPAD is a sterile surgical drape that reduces the effect of scatter radiation on the operator. We sought to assess the efficacy of RADPAD shields in reducing radiation dose experienced by operators during routine diagnostic coronary angiography. Sixty consecutive patients due to undergo elective coronary angiography were randomized in a 1:1 pattern to have their procedures performed with and without the RADPAD drape in situ. Dosimetry was performed on the left arm of the primary operator. There was no significant difference in the two main determents of radiation exposure in both groups: the screening times (102 ± 86 s for the RADPAD group vs. 105 ± 36 s for the control group, p = 0.9) and body mass index (BMI; 27.7 ± 4.2 kg/m 2 for the RADPAD group vs. 27.9 ± 5.5 kg/m 2 for the control group, p = 0.8). Moreover, there was no difference in the dose-area ratio (1337 ± 582 cGy/cm 2 for the RADPAD group vs. 1541 ± 804 cGy/cm 2 for the control group, p = 0.3) between the two patient groups. The primary operator radiation dose was significantly lower in the RADPAD group at 8.0 µSv (Q1: 3.2, Q3: 20.1) compared with 19.6 µSv (Q1: 7.1, Q3: 37.7) for the control group (p = 0.02). The RADPAD significantly reduces radiation exposure to primary operators during routine diagnostic coronary angiography in patients with a BMI > 25 kg/m 2 . It reduces total radiation exposure to primary operators by 59%, and the radiation exposure rate by 47%.

  16. Osteocalcin expression by circulating endothelial progenitor cells in patients with coronary atherosclerosis.

    Science.gov (United States)

    Gössl, Mario; Mödder, Ulrike I; Atkinson, Elizabeth J; Lerman, Amir; Khosla, Sundeep

    2008-10-14

    This study was designed to test whether patients with coronary atherosclerosis have increases in circulating endothelial progenitor cells (EPCs) expressing an osteogenic phenotype. Increasing evidence indicates a link between bone and the vasculature, and bone marrow and circulating osteogenic cells have been identified by staining for the osteoblastic marker, osteocalcin (OCN). Endothelial progenitor cells contribute to vascular repair, but repair of vascular injury may result in calcification. Using cell surface markers (CD34, CD133, kinase insert domain receptor [KDR]) to identify EPCs, we examined whether patients with coronary atherosclerosis had increases in the percentage of EPCs expressing OCN. We studied 72 patients undergoing invasive coronary assessment: control patients (normal coronary arteries and no endothelial dysfunction, n = 21) versus 2 groups with coronary atherosclerosis-early coronary atherosclerosis (normal coronary arteries but with endothelial dysfunction, n = 22) and late coronary atherosclerosis (severe, multivessel coronary artery disease, n = 29). Peripheral blood mononuclear cells were analyzed using flow cytometry. Compared with control patients, patients with early or late coronary atherosclerosis had significant increases (approximately 2-fold) in the percentage of CD34+/KDR+ and CD34+/CD133+/KDR+ cells costaining for OCN. Even larger increases were noted in the early and late coronary atherosclerosis patients in the percentage of CD34+/CD133-/KDR+ cells costaining for OCN (5- and 2-fold, p < 0.001 and 0.05, respectively). A higher percentage of EPCs express OCN in patients with coronary atherosclerosis compared with subjects with normal endothelial function and no structural coronary artery disease. These findings have potential implications for the mechanisms of vascular calcification and for the development of novel markers for coronary atherosclerosis.

  17. Assessment of coronary artery disease with nicorandil stress magnetic resonance imaging

    International Nuclear Information System (INIS)

    Kawase, Yoshio; Nichimoto, Masaki; Hato, Katsunori; Okajima, Kazue; Yoshikawa, Junichi

    2004-01-01

    Although dipyridamole and adenosine have been used as vasodilator agents, we believe they are inadequate for vasodilator perfusion magnetic resonance imaging, due to adverse effects (flushing, warmth, headaches, and arrhythmia). Nicorandil, a potassium channel opener, has been reported to increase coronary blood flow and it was associated with fewer adverse effects than adenosine or dipiridamole. We set out to investigate whether the coronary artery stenosis could be assessed by nicorandil stress perfusion magnetic resonance imaging. First-pass contrast-enhanced magnetic resonance images of the left ventricle acquired from 50 patients at rest and during intravenous administration of nicorandil using multi-slice turbo field echo with multi shot echo-planar-imaging. Coronary angiography was performed within 1 week. There was no adverse effects during nicorandil stress in any patients. The overall sensitivity and specificity of magnetic resonance imaging in identifying patients with significant stenosis of at least one coronary artery were 93.9% (31 of 33 patients) and 94.1% (16 of 17 patients), respectively. The sensitivity of magnetic resonance imaging for detecting significant stenosis in the left anterior descending artery was 87.5%; the sensitivity in the left circumflex artery was 80%; the sensitivity in the right coronary artery was 92.3%. Similar sensitivities were observed for all 3 vascular regions, indicating that all myocardial segments were visualized with similar image quality. The present study shows that nicorandil stress perfusion magnetic resonance imaging is a safe, feasible technique for assessing coronary artery stenosis severity in a totally-noninvasive manner. (authors)

  18. Quantitative relationship between coronary calcium content and coronary flow reserve as assessed by integrated PET/CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Curillova, Zelmira [Brigham and Women' s Hospital, Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Boston, MA (United States); VA Boston Healthcare System, Division of Cardiology, Department of Medicine, West Roxbury, MA (United States); Yaman, Bettina F.; Sitek, Arkadius; El Fakhri, Georges [Brigham and Women' s Hospital, Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Boston, MA (United States); Dorbala, Sharmila [Brigham and Women' s Hospital, Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Boston, MA (United States); Brigham and Women' s Hospital, Noninvasive Cardiovascular Imaging Program, Departments of Medicine (Cardiology) and Radiology, Boston, MA (United States); Kwong, Raymond Y. [Harvard Medical School, Division of Cardiovascular Medicine, Department of Medicine, Brigham and Women' s Hospital, Boston, MA (United States); Brigham and Women' s Hospital, Noninvasive Cardiovascular Imaging Program, Departments of Medicine (Cardiology) and Radiology, Boston, MA (United States); Anagnostopoulos, Constantinos [Brigham and Women' s Hospital, Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Boston, MA (United States); Royal Brompton Hospital, Department of Nuclear Medicine, London (United Kingdom); Di Carli, Marcelo F. [Brigham and Women' s Hospital, Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Boston, MA (United States); Harvard Medical School, Division of Cardiovascular Medicine, Department of Medicine, Brigham and Women' s Hospital, Boston, MA (United States); Brigham and Women' s Hospital, Noninvasive Cardiovascular Imaging Program, Departments of Medicine (Cardiology) and Radiology, Boston, MA (United States); Brigham and Women' s Hospital, Division of Nuclear Medicine and Molecular Imaging, Boston, MA (United States)

    2009-10-15

    To evaluate the relationship between coronary artery calcium (CAC) and coronary vasodilator function. We evaluated 136 patients without known coronary artery disease (CAD) undergoing vasodilator stress {sup 82}Rb PET/CT and CAC scoring who showed normal myocardial perfusion. The CAC score, resting and hyperemic myocardial blood flow (MBF), coronary flow reserve (CFR) and coronary vascular resistance were analyzed. Global and regional CAC scores showed significant but weak inverse correlations with hyperemic MBF (r=-0.31 and r=-0.26, p{<=}0.0002 respectively) and CFR (r=-0.28 and r=-0.2, p{<=}0.001 respectively). With increasing CAC score, there was a modest stepwise decline in CFR on a per-patient basis (1.8{+-}0.5 vs 1.7{+-}0.5 vs 1.5{+-}0.4, p=0.048, with total CAC=0, 1-400 and >400, respectively) and on a per-vessel basis. In multivariable modeling only body mass index and CAC score were predictive of CFR. In patients with an intermediate likelihood of, but without overt, CAD, there is a statistically significant but weak inverse correlation between CAC content and coronary vasodilator function. The strength of this association weakens after adjusting CAC scores for age, gender and coronary risk factors. This suggests that CAC and coronary vasodilator function provide biologically different information regarding atherosclerosis. (orig.)

  19. Quantitative relationship between coronary calcium content and coronary flow reserve as assessed by integrated PET/CT imaging

    International Nuclear Information System (INIS)

    Curillova, Zelmira; Yaman, Bettina F.; Sitek, Arkadius; El Fakhri, Georges; Dorbala, Sharmila; Kwong, Raymond Y.; Anagnostopoulos, Constantinos; Di Carli, Marcelo F.

    2009-01-01

    To evaluate the relationship between coronary artery calcium (CAC) and coronary vasodilator function. We evaluated 136 patients without known coronary artery disease (CAD) undergoing vasodilator stress 82 Rb PET/CT and CAC scoring who showed normal myocardial perfusion. The CAC score, resting and hyperemic myocardial blood flow (MBF), coronary flow reserve (CFR) and coronary vascular resistance were analyzed. Global and regional CAC scores showed significant but weak inverse correlations with hyperemic MBF (r=-0.31 and r=-0.26, p≤0.0002 respectively) and CFR (r=-0.28 and r=-0.2, p≤0.001 respectively). With increasing CAC score, there was a modest stepwise decline in CFR on a per-patient basis (1.8±0.5 vs 1.7±0.5 vs 1.5±0.4, p=0.048, with total CAC=0, 1-400 and >400, respectively) and on a per-vessel basis. In multivariable modeling only body mass index and CAC score were predictive of CFR. In patients with an intermediate likelihood of, but without overt, CAD, there is a statistically significant but weak inverse correlation between CAC content and coronary vasodilator function. The strength of this association weakens after adjusting CAC scores for age, gender and coronary risk factors. This suggests that CAC and coronary vasodilator function provide biologically different information regarding atherosclerosis. (orig.)

  20. Acute coronary syndrome caused by coronary vasospasms associated with Churg-Strauss syndrome: effects of betamethasone therapy.

    Science.gov (United States)

    Suzuki, Yuji; Nishiyama, Osamu; Sakai, Toshiaki; Niiyama, Masanobu; Itoh, Tomonori; Nakamura, Motoyuki

    2014-01-01

    A 42-year-old woman with a history of aspirin-induced asthma was admitted with severe chest pain. Emergency coronary angiography revealed coronary artery spasms. The administration of vasodilators did not suppress the anginal symptoms, and the differential white blood cell count continued to show eosinophilia. The patient's symptoms of aspirin-induced asthma, eosinophilia and other allergic states led to the diagnosis of Churg-Strauss syndrome (CSS). After starting betamethasone therapy, the eosinophilia and cardiac symptoms rapidly disappeared. Although coronary vasospasms related to CSS are rare, the present case suggests that a differential white blood cell count should be obtained in patients with refractory coronary vasospasms.

  1. Cardiovascular risk scores for coronary atherosclerosis.

    Science.gov (United States)

    Yalcin, Murat; Kardesoglu, Ejder; Aparci, Mustafa; Isilak, Zafer; Uz, Omer; Yiginer, Omer; Ozmen, Namik; Cingozbay, Bekir Yilmaz; Uzun, Mehmet; Cebeci, Bekir Sitki

    2012-10-01

    The objective of this study was to compare frequently used cardiovascular risk scores in predicting the presence of coronary artery disease (CAD) and 3-vessel disease. In 350 consecutive patients (218 men and 132 women) who underwent coronary angiography, the cardiovascular risk level was determined using the Framingham Risk Score (FRS), the Modified Framingham Risk Score (MFRS), the Prospective Cardiovascular Münster (PROCAM) score, and the Systematic Coronary Risk Evaluation (SCORE). The area under the curve for receiver operating characteristic curves showed that FRS had more predictive value than the other scores for CAD (area under curve, 0.76, P MFRS, PROCAM, and SCORE) may predict the presence and severity of coronary atherosclerosis.The FRS had better predictive value than the other scores.

  2. Coronary artery assessment by multidetector computed tomography in patients with prosthetic heart valves

    International Nuclear Information System (INIS)

    Habets, Jesse; Mali, Willem P.T.M.; Budde, Ricardo P.J.; Brink, Renee B.A. van den; Uijlings, Ruben; Spijkerboer, Anje M.; Chamuleau, Steven A.J.

    2012-01-01

    Patients with prosthetic heart valves may require assessment for coronary artery disease. We assessed whether valve artefacts hamper coronary artery assessment by multidetector CT. ECG-gated or -triggered CT angiograms were selected from our PACS archive based on the presence of prosthetic heart valves. The best systolic and diastolic axial reconstructions were selected for coronary assessment. Each present coronary segment was scored for the presence of valve-related artefacts prohibiting coronary artery assessment. Scoring was performed in consensus by two observers. Eighty-two CT angiograms were performed on a 64-slice (n = 27) or 256-slice (n = 55) multidetector CT. Eighty-nine valves and five annuloplasty rings were present. Forty-three out of 1160 (3.7%) present coronary artery segments were non-diagnostic due to valve artefacts (14/82 patients). Valve artefacts were located in right coronary artery (15/43; 35%), left anterior descending artery (2/43; 5%), circumflex artery (14/43; 32%) and marginal obtuse (12/43; 28%) segments. All cobalt-chrome containing valves caused artefacts prohibiting coronary assessment. Biological and titanium-containing valves did not cause artefacts except for three specific valve types. Most commonly implanted prosthetic heart valves do not hamper coronary assessment on multidetector CT. Cobalt-chrome containing prosthetic heart valves preclude complete coronary artery assessment because of severe valve artefacts. circle Most commonly implanted prosthetic heart valves do not hamper coronary artery assessment circle Prosthetic heart valve composition determines the occurrence of prosthetic heart valve-related artefacts circle Bjoerk-Shiley and Sorin tilting disc valves preclude diagnostic coronary artery segment assessment. (orig.)

  3. Coronary heart disease risk assessment and characterization of coronary artery disease using coronary CT angiography: comparison of asymptomatic and symptomatic groups

    International Nuclear Information System (INIS)

    Hwang, Y.; Kim, Y.; Chung, I.-M.; Ryu, J.; Park, H.

    2010-01-01

    Aim: To evaluate the prevalence of coronary artery disease (CAD) in relation to risk of coronary heart disease (CHD) and assess plaque characteristics from coronary computed tomography (CT) angiography in asymptomatic and symptomatic patients. Materials and methods: Three hundred and ninety consecutive patients [asymptomatic group, n = 138; symptomatic group (atypical or non-anginal chest pain), n = 252] were retrospectively enrolled. They were subsequently classified into three CHD risk categories, based on the National Cholesterol Education Program guidelines, and 10 year risks of coronary events were calculated using Framingham risk score. CT was evaluated for stenosis, plaque composition, and coronary calcium scores. Results: CAD was observed in 42% of the asymptomatic group and 62% of the symptomatic group. In the former, the prevalence of CAD in low-, moderate- and high-risk subgroups was 21.4, 47.4 and 65%, respectively, and was 33.3, 74.4, and 72.4% in the symptomatic group. Framingham 10-year risks of coronary events were significantly higher in patients with CAD than in normal participants, and receiver operating characteristics curves showed that discriminatory power was poor in the asymptomatic group and symptomatic men, and good in symptomatic women. Of the participants in the asymptomatic group, 12% exhibited only non-calcified plaques and of the symptomatic group, 7% exhibited only non-calcified plaques. The coronary calcium score was significantly higher for significant stenosis than for non-significant stenosis in both groups. Conclusions: The prevalence of CAD was not negligible even in subgroups with low-to-moderate CHD risk. Additionally, the Framingham risk score was effective for predicting CAD only in symptomatic women. Coronary calcium scores correlated with significant stenosis; however, a sizeable percentage of both groups had only non-calcified plaques.

  4. Single-frequency blue light generation by single-pass sum-frequency generation in a coupled ring cavity tapered laser

    DEFF Research Database (Denmark)

    Jensen, Ole Bjarlin; Petersen, Paul Michael

    2013-01-01

    A generic approach for generation of tunable single frequency light is presented. 340 mW of near diffraction limited, single-frequency, and tunable blue light around 459 nm is generated by sum-frequency generation (SFG) between two tunable tapered diode lasers. One diode laser is operated in a ring...... cavity and another tapered diode laser is single-passed through a nonlinear crystal which is contained in the coupled ring cavity. Using this method, the single-pass conversion efficiency is more than 25%. In contrast to SFG in an external cavity, the system is entirely self-stabilized with no electronic...

  5. Wavenumber-domain separation of rail contribution to pass-by noise

    Science.gov (United States)

    Zea, Elias; Manzari, Luca; Squicciarini, Giacomo; Feng, Leping; Thompson, David; Arteaga, Ines Lopez

    2017-11-01

    In order to counteract the problem of railway noise and its environmental impact, passing trains in Europe must be tested in accordance to a noise legislation that demands the quantification of the noise generated by the vehicle alone. However, for frequencies between about 500 Hz and 1600 Hz, it has been found that a significant part of the measured noise is generated by the rail, which behaves like a distributed source and radiates plane waves as a result of the contact with the train's wheels. Thus the need arises for separating the rail contribution to the pass-by noise in that particular frequency range. To this end, the present paper introduces a wavenumber-domain filtering technique, referred to as wave signature extraction, which requires a line microphone array parallel to the rail, and two accelerometers on the rail in the vertical and lateral direction. The novel contributions of this research are: (i) the introduction and application of wavenumber (or plane-wave) filters to pass-by data measured with a microphone array located in the near-field of the rail, and (ii) the design of such filters without prior information of the structural properties of the rail. The latter is achieved by recording the array pressure, as well as the rail vibrations with the accelerometers, before and after the train pass-by. The performance of the proposed method is investigated with a set of pass-by measurements performed in Germany. The results seem to be promising when compared to reference data from TWINS, and the largest discrepancies occur above 1600 Hz and are attributed to plane waves radiated by the rail that so far have not been accounted for in the design of the filters.

  6. Passing particle toroidal precession induced by electric field in a tokamak

    International Nuclear Information System (INIS)

    Andreev, V. V.; Ilgisonis, V. I.; Sorokina, E. A.

    2013-01-01

    Characteristics of a rotation of passing particles in a tokamak with radial electric field are calculated. The expression for time-averaged toroidal velocity of the passing particle induced by the electric field is derived. The electric-field-induced additive to the toroidal velocity of the passing particle appears to be much smaller than the velocity of the electric drift calculated for the poloidal magnetic field typical for the trapped particle. This quantity can even have the different sign depending on the azimuthal position of the particle starting point. The unified approach for the calculation of the bounce period and of the time-averaged toroidal velocity of both trapped and passing particles in the whole volume of plasma column is presented. The results are obtained analytically and are confirmed by 3D numerical calculations of the trajectories of charged particles

  7. Passing particle toroidal precession induced by electric field in a tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Andreev, V. V. [Peoples' Friendship University of Russia, Ordzhonikidze St. 3, Moscow 117198 (Russian Federation); Ilgisonis, V. I.; Sorokina, E. A. [Peoples' Friendship University of Russia, Ordzhonikidze St. 3, Moscow 117198 (Russian Federation); NRC “Kurchatov Institute”, Kurchatov Sq. 1, Moscow 123182 (Russian Federation)

    2013-12-15

    Characteristics of a rotation of passing particles in a tokamak with radial electric field are calculated. The expression for time-averaged toroidal velocity of the passing particle induced by the electric field is derived. The electric-field-induced additive to the toroidal velocity of the passing particle appears to be much smaller than the velocity of the electric drift calculated for the poloidal magnetic field typical for the trapped particle. This quantity can even have the different sign depending on the azimuthal position of the particle starting point. The unified approach for the calculation of the bounce period and of the time-averaged toroidal velocity of both trapped and passing particles in the whole volume of plasma column is presented. The results are obtained analytically and are confirmed by 3D numerical calculations of the trajectories of charged particles.

  8. Coronary plaque property evaluation by coronary CTA and its correlation with inflammatory molecules and MMPs/TIMPs

    Directory of Open Access Journals (Sweden)

    Wen-Bing Yang

    2017-11-01

    Full Text Available Objective: To study the evaluation value of coronary CTA for coronary plaque properties and its correlation with inflammatory molecules and MMPs/TIMPs. Methods: Patients who were diagnosed with acute coronary syndrome in Renmin Hospital of Wuhan University between August 2014 and December 2016 were selected as the ACS group of the research, patients who were diagnosed with stable angina pectoris were selected as the SAP group of the research, and healthy subjects who received physical examination during the same period were selected as the control group of the research. Coronary CTA was done to determine the coronary plaque properties of ACS group, and serum was collected from the three groups of subjects to determine the contents of inflammatory molecules and MMPs/TIMPs collagen metabolites. Results: Serum MIP-1α, MCP-1, sFGL-2, sCD14, CXCL5, I-CTP, III-CTP and EMMPRIN contents of ACS group and SAP group were higher than those of control group while TIMP1, TIMP2 contents were lower than those of control group; serum MIP-1α, MCP-1, sFGL-2, sCD14, CXCL5, I-CTP, III-CTP and EMMPRIN contents of ACS group were higher than those of SAP group while TIMP1 and TIMP2 contents were lower than those of SAP group. Serum MIP-1α, MCP-1, sFGL-2, sCD14, CXCL5, I-CTP, III-CTP and EMMPRIN contents of ACS patients with soft plaque and fibrous plaque were higher than those of ACS patients with calcified plaque while TIMP1 and TIMP2 contents were lower than those of ACS patients with calcified plaque; serum MIP-1α, MCP-1, sFGL-2, sCD14, CXCL5, I-CTP, III-CTP and EMMPRIN contents of ACS patients with soft plaque were higher than those of ACS patients with fibrous plaque while TIMP1, TIMP2 contents were lower than those of ACS patients with fibrous plaque. Conclusion: The coronary plaque property evaluation by coronary CTA is closely related to the changes of inflammatory response and MMPs/TIMPs collagen metabolism.

  9. Comparisons of images simultaneously documented by digital subtraction coronary arteriography and cine coronary arteriography

    International Nuclear Information System (INIS)

    Kimura, Koji; Takamiya, Makoto; Yamamoto, Kazuo; Ohta, Mitsushige; Naito, Hiroaki

    1988-01-01

    Using an angiography apparatus capable of simultaneously processing digital subtraction angiograms and cine angiograms, the diagnostic capabilities of both methods for the coronary arteries (DSCAG and Cine-CAG) were compared. Twenty stenotic lesions of the coronary arteries of 11 patients were evaluated using both modalities. The severity of stenosis using DSCAG with a 512x512x8 bit matrix was semiautomatically measured on the cathode ray tube (CRT) based on enlarged images on the screen of a Vanguard cine projector which were of the same size as those of or 10 times larger than images of Cine-CAG. The negative and positive hard copies of DSCAG images were also compared with those of Cine-CAG. The correlation coefficients of the severity of stenosis by DSCAG and Cine-CAG were as follows: (1) the same size DSCAG images on CRT to Cine-CAG, 0.95, (2) 10 times enlarged DSCAG images on CRT to Cine-CAG, 0.96, and (3) the same size DSCAG images on negative and positive hard copies to Cine-CAG, 0.97. The semiautomatically measured values of 10 times enlarged DSCAG images on CRT and the manually measured values of the same size negative and positive DSCAG images in hard copy closely correlated with the values measured using Cine-CAG. When the liver was superimposed in the long-axis projection, the diagnostic capabilities of DSCAG and Cine-CAG were compared. The materials included 10 left coronary arteriograms and 11 right coronary arteriograms. Diagnostically, DSCAG was more useful than Cine-CAG in the long-axis projection. (author)

  10. Volume and dimensions of angiographically normal coronary arteries assessed by multidetector computed tomography

    DEFF Research Database (Denmark)

    Sørensen, Samuel Kiil; Kühl, Jørgen Tobias; Fuchs, Andreas

    2017-01-01

    BACKGROUND: The objective of this study was to determine normal values for coronary artery volume (CAV) and individual vasculature and segment dimensions. METHODS: We examined 200 healthy volunteers with an Agatston score of 0 and a normal, high quality coronary CTA. Using 320 slice multidetector...... administration and left ventricular mass. The respective contribution of the left and right coronary vascularture is influenced by coronary dominance....

  11. Three-pass protocol scheme for bitmap image security by using vernam cipher algorithm

    Science.gov (United States)

    Rachmawati, D.; Budiman, M. A.; Aulya, L.

    2018-02-01

    Confidentiality, integrity, and efficiency are the crucial aspects of data security. Among the other digital data, image data is too prone to abuse of operation like duplication, modification, etc. There are some data security techniques, one of them is cryptography. The security of Vernam Cipher cryptography algorithm is very dependent on the key exchange process. If the key is leaked, security of this algorithm will collapse. Therefore, a method that minimizes key leakage during the exchange of messages is required. The method which is used, is known as Three-Pass Protocol. This protocol enables message delivery process without the key exchange. Therefore, the sending messages process can reach the receiver safely without fear of key leakage. The system is built by using Java programming language. The materials which are used for system testing are image in size 200×200 pixel, 300×300 pixel, 500×500 pixel, 800×800 pixel and 1000×1000 pixel. The result of experiments showed that Vernam Cipher algorithm in Three-Pass Protocol scheme could restore the original image.

  12. Passing the baton

    CERN Multimedia

    2011-01-01

    It was not only in South Korea that batons were being passed last week. While the cream of the world’s athletes were competing in the World Athletics Championships, the cream of the world’s accelerator scientists were on their way to San Sebastian in Spain for the International Particle Accelerator Conference.  One of them was carrying a rather special baton for a handover of a different kind.   When Fermilab’s Vladimir Shiltsev handed the high-energy frontier baton to CERN’s Mike Lamont on Tuesday, it marked the end of an era: a time to look back on the phenomenal contribution the Tevatron has made to particle physics over its 25-year operational lifetime, and the great contribution Fermilab has made over that period to global collaboration in particle physics. There’s always a lot of emotion involved in passing the baton. In athletics, it’s the triumph of wining or the heartbreak of losing. But for this special baton, the...

  13. Localization strategy for magnetic resonance coronary angiography

    International Nuclear Information System (INIS)

    Cheng Liuquan; Gao Yuangui; Sun Wei; Sheng Fugeng; Cai Youquan

    2003-01-01

    Objective: To develop a localization strategy for magnetic resonance coronary angiography (MRCA). Methods: In 89 subjects, the standard 4-chamber view and long-axis view of left and right ventricle were acquired using Fast-Imaging-Employing-Steady-State-Acquisition (FIESTA) sequence in CINE mode, and the trigger-delay time for mid-diastolic phase was determined. Coronary vessels including right coronary artery (RCA), left main (LM), left anterior descending (LAD), and left circumflex (LCX) were localized and imaged using 3- dimensional fat-suppressed FIESTA sequence during end-expiration. The reproducibility of the localization strategy was evaluated by taking the standard of coronary segmentation system recommended by American Heart Association. Results: Eighty-six subjects completed the examination with full respiratory co-operation and the indication ratio was 96.63%. Nine planes were optimized as the standard to target the main branches of coronary arteries, and a comprehensive reproducibility reached 100% in demonstrating the proximal and middle segment of RCA (AHA-18, 19), LM (AHA-1, 2), proximal and middle segment of LAD (AHA-3, 5, 7), and proximal LCX (AHA-10). The reproducibility for the demonstration of distal segments of LAD, LCX, and RCA (AHA-9, 14, 21) was 94.19%, 72.09%, and 96.51%, respectively. Conclusion: This is a simple and practical localization strategy for MRCA. It could image the proximal and middle segments of the coronary arteries with good reproducibility, which indicates the potential for clinical application

  14. Coronary Flow Velocity Reserve Assessed by Transthoracic Doppler

    DEFF Research Database (Denmark)

    Michelsen, Marie M; Peña, Adam; Mygind, Naja D

    2016-01-01

    the feasibility and factors associated with the quality of CFVR obtained in a large prospective study of women suspected of having microvascular disease. METHODS: Women with angina-like chest pain and no obstructive coronary artery disease on coronary angiography (

  15. Thallium-201 myocardial imaging during coronary vasodilation induced by oral dipyridamole

    International Nuclear Information System (INIS)

    Gould, K.L.; Sorenson, S.G.; Albro, P.; Caldwell, J.H.; Chaudhuri, T.; Hamilton, G.W.

    1986-01-01

    Myocardial perfusion imaging of 201 TI injected during maximum exercise has been an important diagnostic tool for coronary artery disease. Pharmacologic coronary vasodilation by i.v. infusion of dipyridamole may be used in lieu of exercise stress for purposes of diagnostic perfusion imaging. However, i.v. dipyridamole is not currently available from commercial sources for widespread routine use. Accordingly, this study was carried out in order to determine whether high dose, oral dipyridamole would be useful as a coronary vasodilator for purposes of diagnostic perfusion imaging. Fifty-eight patients undergoing diagnostic coronary arteriography also had myocardial perfusion imaging with 201TI under conditions of rest, maximum exercise stress, and high dose oral dipyridamole. Of those patients who had a defect on exercise thallium images, 75% also had a perfusion defect on thallium images after high dose oral dipyridamole. These results indicate that oral dipyridamole causes sufficient coronary arteriolar vasodilation and increase of coronary flow in nonstenotic arteries to identify perfusion defects comparable to those seen on maximum exercise stress in at least 75% of cases. In 25% of patients with exercise defects, no perfusion defect was seen after oral dipyridamole. Thus, oral dipyridamole is a potent coronary vasodilator, comparable to exercise stress in most cases, but in a minority of patients may not be comparable to exercise stress

  16. Acute organophosphorus poisoning complicated by acute coronary syndrome.

    Science.gov (United States)

    Pankaj, Madhu; Krishna, Kavita

    2014-07-01

    We report a case of 30 year old alcoholic male admitted with vomiting, drowsiness, limb weakness and fasciculations after alleged history of consumption of 30 ml of chlorpyriphos insecticide. He had low serum cholinesterase levels. With standard treatment for organophosphorus poisoning (OPP), he improved gradually until day 5, when he developed neck and limb weakness and respiratory distress. This intermediate syndrome was treated with oximes, atropine and artificial ventilation. During treatment, his ECG showed fresh changes of ST elevation. High CPK & CPK-MB levels, septal hypokinesia on 2D echo suggested acute coronary syndrome. Coronary angiography was postponed due to his bedridden and obtunded status. The patient finally recovered fully by day 15 and was discharged. Acute coronary syndrome is a rare occurrence in OP poisoning. The present case thus emphasises the need for careful electrocardiographic and enzymatic monitoring of all patients of organophosphorus poisoning to prevent potential cardiac complication which can prove fatal.

  17. Histologic Comparison of Vibrating Guidewire with Conventional Guidewire Technique in an Experimental Coronary In Vivo Model

    International Nuclear Information System (INIS)

    Katsouras, Christos S.; Michalis, Lampros K.; Malamou-Mitsi, Vassiliki D.; Niokou, Demetra; Giogiakas, Vassilios; Nikas, Dimitrios; Massouras, Gerasimos; Dallas, Pavlos; Tsetis, Dimitrios K.; Sideris, Dimitris A.; Rees, Michael R.

    2003-01-01

    Purpose: To compare the damage caused by vibrating guidewire manipulation and conventional guidewire manipulation of soft coronary wires in normal sheep coronary arteries. Methods: Using an intact sheep model the two methods of passing a coronary guidewire down a normal coronary artery under fluoroscopic screening control were studied. The resulting arterial damage caused by the two techniques was studied histologically. The severity of damage was scored from 1 (no damage) to 4 (severe damage) and expressed as: (a) percentage of damaged sections, (b) mean damage score per section and (c) percentage of sections suffering the most severe degree of damage (scores 3 and 4). Results: One hundred and sixty-eight sections were studied.The percentage of damaged sections was lower in the vibrating guidewire group (p 0.004). The mean damage score and the percentage of sections with a damage score of 3 or 4 were smaller in the vibrating guidewire group than in the conventional guidewire manipulation group (p = 0.001 and p =0.009, respectively). Conclusions: Both methods of guidewire manipulation cause identifiable vascular damage. The extent and severity of damage appear greater when the guidewire is manipulated manually

  18. Detection of coronary calcification in ultrafast CT compared to coronary angiography

    International Nuclear Information System (INIS)

    Koesling, S.; Hoffmann, U.; Rother, T.; Lieberenz, S.; Heywang-Koebrunner, S.H.; Schulz, H.G.

    1994-01-01

    The angiographical findings of 24 patients with coronary artery disease were compared with qualitative and quantitative detection of coronary calcification by ultrafast CT. Doubts concerning the capabilities of the ultrafast CT for a screening of coronary artery disease arise when the results of one third false positive and fase negative findings are considered. Variations in the quantification of coronary calcification were too great to allow a realistic assessment of the degree of stenosis of the coronary arteries. (orig.) [de

  19. Inhibition of coronary blood flow by a vascular waterfall mechanism.

    Science.gov (United States)

    Downey, J M; Kirk, E S

    1975-06-01

    The mechanism whereby systole inhibits coronary blood flow was examined. A branch of the left coronary artery was maximally dilated with an adenosine infusion, and the pressure-flow relationship was obtained for beating and arrested states. The pressure-flow curve for the arrested state was shifted toward higher pressures and in the range of pressures above peak ventricular pressure was linear and parallel to that for the arrested state. Below this range the curve for the beating state converged toward that for the arrested state and was convex to the pressure axis. These results were compared with a model of the coronary vasculature that consisted of numerous parallel channels, each responding to local intramyocardial pressure by forming vascular waterfalls. When intramyocardial pressure in the model was assigned values from zero at the epicardium to peak ventricular pressure at the endocardium, pressure-flow curves similar to the experimental ones resulted. Thus, we conclude that systole inhibits coronary perfusion by the formation of vascular waterfalls and that the intramyocardial pressures responsible for this inhibition do not significantly exceed peak ventricular pressure.

  20. Realisation of low-voltage square-root-domain all-pass filters

    Directory of Open Access Journals (Sweden)

    Farooq A. Khanday

    2013-10-01

    Full Text Available Novel l ow-voltage first-order and second-order square-root-domain all-pass filters derived systematically by means of transfer function decomposition and state -space synthesis techniques are proposed. The employment of only a few geometric-mean cells and grounded capacitors permits the circuits to absorb shunt parasitic capacitances, which is desirable for production in monolithic form . The circuits enjoy the features of electronic adjustment of frequency characteristics, wider dynamic range and low-voltage environment operation. The filters are employed to design high-order all-pass filters using cascade approach. First-order low-pass and second-order band-pass filters, being the inherited building blocks of the proposed low-order all-pass filters are also discussed. The behaviour of the filters is evaluated through simulations using Taiwan semiconductor manufacturing company 0.25 μm level-3 complementary metal oxide semiconductor process parameters, where the most important performance factors are considered.

  1. Congenital Left Circumflex Coronary Artery Atresia Detected by 64-Slice Computed Tomography: A Case Report

    Directory of Open Access Journals (Sweden)

    Chen-Yuan Liu

    2007-06-01

    Full Text Available A variety of coronary artery disorders, including intramyocardial coronary segments and coronary artery anomalies, can result in sudden cardiac death, especially in young adults. The detection of structural coronary artery abnormalities is important in the management of patients at risk of sudden cardiac death. Coronary artery anomalies occur in about 1% of the population. Congenital absence of left circumflex coronary artery (LCX is a very rare vascular anomaly, and few cases have been reported in the literature, with a frequency of only 0.003% in all patients who underwent coronary angiography. Although coronary catheterization is the gold standard for the evaluation of coronary arterial patency disease, noninvasive computed tomography (CT is considered the diagnostic method of choice for the detection and evaluation of coronary artery anomaly. Herein, we report the case of a 17-year-old girl who presented with exertional dyspnea and chest pain and who was studied at our emergency department with the final diagnosis of LCX atresia detected by 64-slice CT. She may be the first case of congenital LCX atresia proved by multislice CT.

  2. [Developments in percutaneous coronary intervention and coronary stents].

    Science.gov (United States)

    Simsek, C; Daemen, J; Zijlstra, F

    2014-01-01

    In The Netherlands, more than 30.000 patients undergo a percutaneous coronary intervention every year, during which a coronary stent implantation will be performed in 90% of the cases. It is estimated that more than 5 million coronary stent implantations will be performed worldwide this year. While these numbers are impressive, however, coronary stents still have as a limitation the possibility of stent thrombosis. This has been and is an important stimulus for the development of both coronary stents, from a bare metal stent via a drug eluting stent to the present-day development of bio-absorbable stents, and anti-platelet drugs,from acenocoumarol to thieropyridines. The possibility of shortening the period of use of this powerful medication by developing new kinds of non-thrombogenic stents would, for example, make it possible to achieve significant reductions in subsequent bleeding during (dental) procedures.

  3. The Coronary Artery Disease-Reporting and Data System (CAD-RADS): Prognostic and Clinical Implications Associated With Standardized Coronary Computed Tomography Angiography Reporting.

    Science.gov (United States)

    Xie, Joe X; Cury, Ricardo C; Leipsic, Jonathon; Crim, Matthew T; Berman, Daniel S; Gransar, Heidi; Budoff, Matthew J; Achenbach, Stephan; Ó Hartaigh, Bríain; Callister, Tracy Q; Marques, Hugo; Rubinshtein, Ronen; Al-Mallah, Mouaz H; Andreini, Daniele; Pontone, Gianluca; Cademartiri, Filippo; Maffei, Erica; Chinnaiyan, Kavitha; Raff, Gilbert; Hadamitzky, Martin; Hausleiter, Joerg; Feuchtner, Gudrun; Dunning, Allison; DeLago, Augustin; Kim, Yong-Jin; Kaufmann, Philipp A; Villines, Todd C; Chow, Benjamin J W; Hindoyan, Niree; Gomez, Millie; Lin, Fay Y; Jones, Erica; Min, James K; Shaw, Leslee J

    2018-01-01

    This study sought to assess clinical outcomes associated with the novel Coronary Artery Disease-Reporting and Data System (CAD-RADS) scores used to standardize coronary computed tomography angiography (CTA) reporting and their potential utility in guiding post-coronary CTA care. Clinical decision support is a major focus of health care policies aimed at improving guideline-directed care. Recently, CAD-RADS was developed to standardize coronary CTA reporting and includes clinical recommendations to facilitate patient management after coronary CTA. In the multinational CONFIRM (COronary CT Angiography EvaluatioN For Clinical Outcomes: An InteRnational Multicenter) registry, 5,039 patients without known coronary artery disease (CAD) underwent coronary CTA and were stratified by CAD-RADS scores, which rank CAD stenosis severity as 0 (0%), 1 (1% to 24%), 2 (25% to 49%), 3 (50% to 69%), 4A (70% to 99% in 1 to 2 vessels), 4B (70% to 99% in 3 vessels or ≥50% left main), or 5 (100%). Kaplan-Meier and multivariable Cox models were used to estimate all-cause mortality or myocardial infarction (MI). Receiver-operating characteristic (ROC) curves were used to compare CAD-RADS to the Duke CAD Index and traditional CAD classification. Referrals to invasive coronary angiography (ICA) after coronary CTA were also assessed. Cumulative 5-year event-free survival ranged from 95.2% to 69.3% for CAD-RADS 0 to 5 (p data, 57% of CAD-RADS 3 patients who received 30-day ICA were either asymptomatic or not receiving antianginal therapy at baseline, whereas only 32% had angina and were receiving medical therapy. CAD-RADS effectively identified patients at risk for adverse events. Frequent ICA use was observed among patients without severe CAD, many of whom were asymptomatic or not taking antianginal drugs. Incorporating CAD-RADS into coronary CTA reports may provide a novel opportunity to promote evidence-based care post-coronary CTA. Copyright © 2018 American College of Cardiology

  4. New noninvasive diagnosis of myocardial ischemia of the left circumflex coronary artery using coronary flow reserve measurement by transthoracic Doppler echocardiography. Comparison with thallium-201 single photon emission computed tomography

    International Nuclear Information System (INIS)

    Fujimoto, Kohei; Watanabe, Hiroyuki; Hozumi, Takeshi; Otsuka, Ryo; Hirata, Kumiko; Yamagishi, Hiroyuki; Yoshiyama, Minoru; Yoshikawa, Junichi

    2004-01-01

    The usefulness of coronary flow reserve measurement in the left circumflex coronary artery by transthoracic Doppler echocardiography to detect myocardial ischemia was compared with exercise thallium-201 single photon emission computed tomography (SPECT). Transthoracic Doppler echocardiography was performed in 110 patients with suspected coronary artery disease. Color Doppler signals of the left circumflex coronary artery flow in the apical four-chamber view were identified, and the velocities at rest and during hyperemia recorded for calculation of coronary flow reserve by the pulsed Doppler method. All patients underwent SPECT within 1 week of the transthoracic Doppler echocardiographic study. Coronary flow reserve in the left circumflex coronary artery was measured in 79 (72%) of 110 patients. SPECT revealed reversible perfusion defect in the left circumflex coronary artery territories in 12 of 69 patients excluding those with multivessel disease. Coronary flow reserve <2.0 had a sensitivity of 92% and specificity of 96% for reversible perfusion defect detected by SPECT. Noninvasive coronary flow reserve measurement in the left circumflex coronary artery by transthoracic Doppler echocardiography can estimate myocardial ischemia in the left ventricular lateral regions. (author)

  5. Assessment of coronary artery disease and calcified coronary plaque burden by computed tomography in patients with and without diabetes mellitus

    Energy Technology Data Exchange (ETDEWEB)

    Maffei, Erica; Seitun, Sara [Azienda Ospedaliero-Universitaria di Parma, Department of Radiology and Cardiology, Parma (Italy); Nieman, Koen; Weustink, Annick C.; Mollet, Nico R. [Erasmus Medical Center, Department of Radiology and Cardiology, Rotterdam (Netherlands); Martini, Chiara [Azienda Ospedaliero-Universitaria di Parma, Department of Radiology and Cardiology, Parma (Italy); Erasmus Medical Center, Department of Radiology and Cardiology, Rotterdam (Netherlands); Guaricci, Andrea Igoren [Azienda Ospedaliero-Universitaria di Foggia, Department of Cardiology, Foggia (Italy); Tedeschi, Carlo [Ospedale San Gennaro, Department of Cardiology, Naples (Italy); Berti, Elena; Grilli, Roberto [Regione Emilia-Romagna, Healthcare and Social Agency, Bologna (Italy); Messalli, Giancarlo [SDN Foundation, IRCCS, Naples (Italy); Cademartiri, Filippo [Azienda Ospedaliero-Universitaria di Parma, Department of Radiology and Cardiology, Parma (Italy); Erasmus Medical Center, Department of Radiology and Cardiology, Rotterdam (Netherlands); Azienda Ospedaliero-Universitaria - Parma, Department of Radiology, Parma (Italy)

    2011-05-15

    To compare the coronary atherosclerotic burden in patients with and without type-2 diabetes using CT Coronary Angiography (CTCA). 147 diabetic (mean age: 65 {+-} 10 years; male: 89) and 979 nondiabetic patients (mean age: 61 {+-} 13 years; male: 567) without a history of coronary artery disease (CAD) underwent CTCA. The per-patient number of diseased coronary segments was determined and each diseased segment was classified as showing obstructive lesion (luminal narrowing >50%) or not. Coronary calcium scoring (CCS) was assessed too. Diabetics showed a higher number of diseased segments (4.1 {+-} 4.2 vs. 2.1 {+-} 3.0; p < 0.0001); a higher rate of CCS > 400 (p < 0.001), obstructive CAD (37% vs. 18% of patients; p < 0.0001), and fewer normal coronary arteries (20% vs. 42%; p < 0.0001), as compared to nondiabetics. The percentage of patients with obstructive CAD paralleled increasing CCS in both groups. Diabetics with CCS {<=} 10 had a higher prevalence of coronary plaque (39.6% vs. 24.5%, p = 0.003) and obstructive CAD (12.5% vs. 3.8%, p = 0.01). Among patients with CCS {<=} 10 all diabetics with obstructive CAD had a zero CCS and one patient was asymptomatic. Diabetes was associated with higher coronary plaque burden. The present study demonstrates that the absence of coronary calcification does not exclude obstructive CAD especially in diabetics. (orig.)

  6. [Successful correction with stent-graft of coronary artery rupture after angioplasty].

    Science.gov (United States)

    Demin, V V

    2003-01-01

    Rupture and perforation of coronary arteries complicate in average 0.5% of radiosurgical coronary interventions and often are accompanied by serious consequences and high mortality. According to-type of coronary perforation different methods of correction are used, ranging from conservative measures to urgent cardiosurgical interventions. Coronary stent-grafts with 'sandwich' type of construction ore composed from two metal stents and PTFE layer between them. Development of such stents enabled effective radioguided endovascular repair of coronary ruptures. The paper presents the first Russian experience of stout-graft implantation for coronary artery rupture occurred during direct stenting of proximal anterior descending artery and balloon angioplasty in distal segment. The rupture occurred probably because of wall fragility between affected segment and muscular bridge. Stent-graft JoStent 16 mm in length connected with 3-mm balloon was implanted with subsequent complete restitution of blood flow, resolution of pain syndrome and ECG normalization. Echocardiography in operative theatre and one day after surgery showed no intrapericardial fluid. Stent-graft devices for urgent implantation in cases of coronary rupture must be included into obligatory equipment of radiosurgical facilities.

  7. Coronary CT Angiography in the Quantitative Assessment of Coronary Plaques

    Directory of Open Access Journals (Sweden)

    Zhonghua Sun

    2014-01-01

    Full Text Available Coronary computed tomography angiography (CCTA has been recently evaluated for its ability to assess coronary plaque characteristics, including plaque composition. Identification of the relationship between plaque composition by CCTA and patient clinical presentations may provide insight into the pathophysiology of coronary artery plaque, thus assisting identification of vulnerable plaques which are associated with the development of acute coronary syndrome. CCTA-generated 3D visualizations allow evaluation of both coronary lesions and lumen changes, which are considered to enhance the diagnostic performance of CCTA. The purpose of this review is to discuss the recent developments that have occurred in the field of CCTA with regard to its diagnostic accuracy in the quantitative assessment of coronary plaques, with a focus on the characterization of plaque components and identification of vulnerable plaques.

  8. Fuel-element failures in Hanford single-pass reactors 1944--1971

    Energy Technology Data Exchange (ETDEWEB)

    Gydesen, S.P.

    1993-07-01

    The primary objective of the Hanford Environmental Dose Reconstruction (HEDR) Project is to estimate the radiation dose that individuals could have received as a result of emissions since 1944 from the US Department of Energy`s (DOE) Hanford Site near Richland, Washington. To estimate the doses, the staff of the Source Terms Task use operating information from historical documents to approximate the radioactive emissions. One source of radioactive emissions to the Columbia River came from leaks in the aluminum cladding of the uranium metal fuel elements in single-pass reactors. The purpose of this letter report is to provide photocopies of the documents that recorded these failures. The data from these documents will be used by the Source Terms Task to determine the contribution of single-pass reactor fuel-element failures to the radioactivity of the reactor effluent from 1944 through 1971. Each referenced fuel-element failure occurring in the Hanford single-pass reactors is addressed. The first recorded failure was in 1948, the last in 1970. No records of fuel-element failures were found in documents prior to 1948. Data on the approximately 2000 failures which occurred during the 28 years (1944--1971) of Hanford single-pass reactor operations are provided in this report.

  9. Two-pass greedy regular expression parsing

    DEFF Research Database (Denmark)

    Grathwohl, Niels Bjørn Bugge; Henglein, Fritz; Nielsen, Lasse

    2013-01-01

    We present new algorithms for producing greedy parses for regular expressions (REs) in a semi-streaming fashion. Our lean-log algorithm executes in time O(mn) for REs of size m and input strings of size n and outputs a compact bit-coded parse tree representation. It improves on previous algorithms...... by: operating in only 2 passes; using only O(m) words of random-access memory (independent of n); requiring only kn bits of sequentially written and read log storage, where k ... and not requiring it to be stored at all. Previous RE parsing algorithms do not scale linearly with input size, or require substantially more log storage and employ 3 passes where the first consists of reversing the input, or do not or are not known to produce a greedy parse. The performance of our unoptimized C...

  10. Coronary blood flow and coronary stenosis correlations in ischemic heart patients

    International Nuclear Information System (INIS)

    Manukov, I.

    2003-01-01

    The aim of the study is the assessment of the methodology for the C-TIMI frame count by Gibson for easy and fast determination of the coronary blood flow during a selective coronary angiography. 75 patient have been studied with one-branch affection of the coronary arteries. The criteria for exclusion are: myocardial hypertrophy, valve lesions, myocardial infarction and dyslipidemia. Depending of the characteristics of the coronary stenotic changes, the patients have been divided into two groups: 1) Patients with 'ordinary' stenosis of the coronary artery and 2) Patients with 'complex' stenosis. The severity of the stenotic changes in percents is the same for the two groups - 78%±13% vs 81±12%, respectively. In the first group a pronounced correlation is observed between the severity of the coronary stenosis and the slowing of the coronary blood flow. The 'threshold' stenotic level is 89%. In the second group the lowest value of the coronary stenosis is 73% (p>0.01 vs group 1). No correlation is observed between the severity of the coronary stenosis and the slowing of the coronary blood flow. A conclusion is made that the Gibson method for the assessment of the blood flow is convenient for the daily practice not only for the assessment of the significance of the coronary changes, but also for fast analysis of the achieved reconstruction of the coronary arteries after angioplasty. Additional studies of the significance of the different signs of 'complexity' of the coronary stenosis for the slowing of the blood flow are necessary

  11. CT coronary angiography vs. invasive coronary angiography in CHD

    Directory of Open Access Journals (Sweden)

    Anja Hagen

    2012-04-01

    Full Text Available Scientific background: Various diagnostic tests including conventional invasive coronary angiography and non-invasive computed tomography (CT coronary angiography are used in the diagnosis of coronary heart disease (CHD. Research questions: The present report aims to evaluate the clinical efficacy, diagnostic accuracy, prognostic value cost-effectiveness as well as the ethical, social and legal implications of CT coronary angiography versus invasive coronary angiography in the diagnosis of CHD. Methods: A systematic literature search was conducted in electronic data bases (MEDLINE, EMBASE etc. in October 2010 and was completed with a manual search. The literature search was restricted to articles published from 2006 in German or English. Two independent reviewers were involved in the selection of the relevant publications. The medical evaluation was based on systematic reviews of diagnostic studies with invasive coronary angiography as the reference standard and on diagnostic studies with intracoronary pressure measurement as the reference standard. Study results were combined in a meta-analysis with 95 % confidence intervals (CI. Additionally, data on radiation doses from current non-systematic reviews were taken into account. A health economic evaluation was performed by modelling from the social perspective with clinical assumptions derived from the meta-analysis and economic assumptions derived from contemporary German sources. Data on special indications (bypass or in-stent-restenosis were not included in the evaluation. Only data obtained using CT scanners with at least 64 slices were considered. Results: No studies were found regarding the clinical efficacy or prognostic value of CT coronary angiography versus conventional invasive coronary angiography in the diagnosis of CHD. Overall, 15 systematic reviews with data from 44 diagnostic studies using invasive coronary angiography as the reference standard (identification of obstructive

  12. Supracristal ventricular septal defect with severe right coronary cusp prolapse

    International Nuclear Information System (INIS)

    Hussain, A.H.; Hanif, B.; Khan, G.; Hasan, K.

    2011-01-01

    The case of a 20 years old male, diagnosed as supracristal ventricular septal defect (VSD) for last 6 years is being presented. He came in emergency department with decompensated congestive cardiac failure. After initial stabilization, he underwent trans thoracic echocardiogram which showed large supracristal VSD, severely prolapsing right coronary cusp, severe aortic regurgitation and severe pulmonary hypertension. Right heart catheterization was performed which documented reversible pulmonary vascular resistance after high flow oxygen inhalation. He underwent VSD repair, right coronary cusp was excised and aortic valve was replaced by mechanical prosthesis. Post operative recovery was uneventful. He was discharged home in one week.The case of a 20 years old male, diagnosed as supracristal ventricular septal defect (VSD) for last 6 years is being presented. He came in emergency department with decompensated congestive cardiac failure. After initial stabilization, he underwent trans thoracic echocardiogram which showed large supracristal VSD, severely prolapsing right coronary cusp, severe aortic regurgitation and severe pulmonary hypertension. Right heart catheterization was performed which documented reversible pulmonary vascular resistance after high flow oxygen inhalation. He underwent VSD repair, right coronary cusp was excised and aortic valve was replaced by mechanical prosthesis. Post operative recovery was uneventful. He was discharged home in one week. (author)

  13. HUMAN CORONARY ARTERIES- A STUDY BASED ON GROSS ANATOMY AND CORONARY CAST

    Directory of Open Access Journals (Sweden)

    Vijayamma K. N

    2018-01-01

    Full Text Available BACKGROUND Present study is an attempt to throw light upon the coronary arterial pattern, variations in arterial distribution and extent of intercoronary anastomosis and arterial preponderance in different age groups. MATERIALS AND METHODS Total of 115 hearts were made use for this study. Ninety hearts were dissected for the gross anatomical study of coronary arteries and 25 hearts including three fetal hearts were used for the coronary cast study. The right and left coronary arteries were traced from aortic sinus along the atrioventricular groove to the area of its termination. The atrial ventricular and septal branches were traced and looked for anastomosis. Coronary casts were prepared by injecting coloured liquid latex through the coronary ostia and the branching pattern and anastomosis were studied. The coronary arterial pattern, extent of distribution of its branches, arterial preponderance and variations were observed. RESULTS It was found that 73 % cases of SA nodal branch arise from right coronary artery and 27 % from circumflex branch of left coronary artery. SA node has dual blood supply from both coronary arteries in 4% cases. Right coronary preponderance was observed in 83% of cases and left coronary preponderance in 11 % cases, and balanced supply in 6% cases. Coronary cast was helpful to understand the branching pattern of vessels, and the anastomosis of small capillaries. It was also seen that all 11 % of left preponderance were seen in male hearts and all of the 31 female hearts dissected were right preponderant. CONCLUSION Coronary arteries are called end arteries functionally. Right coronary artery originates from anterior aortic sinus in all cases except one which takes origin from posterior left aortic sinus along with left coronary artery. Right coronary preponderance is observed in 83% cases. Left coronary artery branching pattern shows variability. Left coronary preponderance was observed in 11% and all cases are male

  14. Economic consequences of extra by-passes in district heating networks. Investment-, running- and maintenance costs

    International Nuclear Information System (INIS)

    Herbert, P.

    1995-02-01

    For various reasons, extra by-passes are installed in district heating networks to ensure a high flow temperature when the water circulation is insufficient. By 'extra by-pass' we here mean a connection between the distribution pipe and the return pipe. This study mainly deals with extra by-passes to prevent freezing. The estimation of the extra by-pass costs is based on the district heating rates. Our assumption is that an extra by-pass can be regarded as a substation in the district heating network, with regard to the demand for the water flow, heat and power. The reason is the difficulty to obtain available facts to estimate the real costs concerning extra by-passes. Therefore, the method can not claim that the information about the costs is exact but gives an indication of the size of them. The valves in an extra by-pass can be set more or less open. We assume that manual valves in extra by-passes are wide open. Thermostatic valves are, however, assumed to be adjusted in order to cause a very small water flow. 2 refs, 16 figs, 9 tabs, 6 appendices

  15. INVESTIGATION OF SINGLE-PASS/DOUBLE-PASS TECHNIQUES ON FRICTION STIR WELDING OF ALUMINIUM

    Directory of Open Access Journals (Sweden)

    N.A.A. Sathari

    2014-12-01

    Full Text Available The aim of this research is to study the effects of single-pass/ double-pass techniques on friction stir welding of aluminium. Two pieces of AA1100 with a thickness of 6.0 mm were friction stir welded using a CNC milling machine at rotational speeds of 1400 rpm, 1600 rpm and 1800 rpm respectively for single-pass and double-pass. Microstructure observations of the welded area were studied using an optical microscope. The specimens were tested by using a tensile test and Vickers hardness test to evaluate their mechanical properties. The results indicated that, at low rotational speed, defects such as ‘surface lack of fill’ and tunnels in the welded area contributed to a decrease in mechanical properties. Welded specimens using double-pass techniques show increasing values of tensile strength and hardness. From this investigation it is found that the best parameters of FSW welded aluminium AA1100 plate were those using double-pass techniques that produce mechanically sound joints with a hardness of 56.38 HV and 108 MPa strength at 1800 rpm compared to the single-pass technique. Friction stir welding, single-pass/ double-pass techniques, AA1100, microstructure, mechanical properties.

  16. Coronary Vasospastic Angina: Assessment by Multidetector CT Coronary Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Koung Mi; Choi, Sang Il; Chun, Eun Ju; Kim, Jeong A; Youn, Tae Jin; Choi, Dong Ju [Seoul National University Bundang Hospital, Sungnam (Korea, Republic of)

    2012-01-15

    We aimed to describe the imaging findings of multidetector CT coronary angiography (MDCTA) in cases of vasospastic angina (VA) and to determine the accuracy of MDCTA in the identification of VA as compared with invasive coronary angiography with an ergonovine provocation test (CAG with an EG test). Fifty-three patients with clinically suspected VA were enrolled in this study. Two radiologists analyzed the stenosis degree, presence or absence of plaque, plaque composition, and a remodeling index of the related-segment in CAG with an EG test, which were used as a gold standard. We evaluated the diagnostic performances of MDCTA by comparing the MDCTA findings with those of CAG with an EG test. Among the 25 patients with positive CAG with an EG test, all 12 patients with significant stenosis showed no definite plaque with the negative arterial remodeling. Of the six patients with insignificant stenosis, three (50%) had non-calcified plaque (NCP), two (33%) had mixed plaque, and one (17%) had calcified plaque. When the criteria for significant stenosis with negative remodeling but no definite evidence of plaque as a characteristic finding of MDCTA were used, results showed sensitivities, specificities, positive predictive values (PPV), and negative predictive values (NPV) of 48%, 100%, 100%, and 68%, respectively. Significant stenosis with negative remodeling, but no definite evidence of plaque, is the characteristic finding on MDCTA of VA. Cardiac MDCTA shows good diagnostic performance with high specificity and PPV as compared with CAG with an EG test.

  17. Transradial access for coronary angiography: a single operator's experience of 500 cases

    International Nuclear Information System (INIS)

    Ali, J.; Aziz, S.; Javed, A.; Kayani, A.M.

    2011-01-01

    Objective: The purpose of the present study was to assess the feasibility, success, and safety of the transradial approach (TRA) for diagnostic coronary angiography. Study Design: Descriptive study. Place and Duration of Study: The study was carried out in Armed Forces Institute of Cardiology- National Institute of Heart Diseases (AFIC-NIHD) over a period of ten months from June 2009 to March 2010. Patients and Methods: We collected data of 500 consecutive patients who underwent coronary catheterization by the transradial approach. Transradial access was performed only if the Allen's test was normal (positive). Patients with previous CABG or requiring right heart catheterization were excluded from this study. Study endpoints included procedure success rate, vascular complications at access site, and major adverse cardiac and cerebrovascular events during hospitalization. Results: Mean age of the patients was 52 years (range 33-77 yrs) and 72.8% (n= 364) were men and 27.2% (n=136) were females. The vast majority of cases (98.4%) were elective. The right radial artery was used in 98% of cases. Procedural success was achieved in 90.6% cases (453/500). No case of vascular complications such as major access site bleeding, vascular perforation, radial artery occlusion, forearm ischemia, compartment syndrome or MACE was observed. Conclusion: Transradial access for coronary angiography is a safe, effective and elegant alternative to trans femoral access. (author)

  18. Incremental value of the CT coronary calcium score for the prediction of coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Genders, Tessa S.S. [Erasmus University Medical Center, Department of Epidemiology, P.O. Box 2040, CA, Rotterdam (Netherlands); Erasmus University Medical Center, Department of Radiology, P.O. Box 2040, CA, Rotterdam (Netherlands); Pugliese, Francesca; Mollet, Nico R.; Meijboom, W. Bob; Weustink, Annick C.; Mieghem, Carlos A.G. van; Feyter, Pim J. de [Erasmus University Medical Center, Department of Radiology, P.O. Box 2040, CA, Rotterdam (Netherlands); Erasmus University Medical Center, Department of Cardiology, P.O. Box 2040, CA, Rotterdam (Netherlands); Hunink, M.G.M. [Erasmus University Medical Center, Department of Epidemiology, P.O. Box 2040, CA, Rotterdam (Netherlands); Erasmus University Medical Center, Department of Radiology, P.O. Box 2040, CA, Rotterdam (Netherlands); Harvard University, Department of Health Policy and Management, Harvard School of Public Health, Boston (United States)

    2010-10-15

    To validate published prediction models for the presence of obstructive coronary artery disease (CAD) in patients with new onset stable typical or atypical angina pectoris and to assess the incremental value of the CT coronary calcium score (CTCS). We searched the literature for clinical prediction rules for the diagnosis of obstructive CAD, defined as {>=}50% stenosis in at least one vessel on conventional coronary angiography. Significant variables were re-analysed in our dataset of 254 patients with logistic regression. CTCS was subsequently included in the models. The area under the receiver operating characteristic curve (AUC) was calculated to assess diagnostic performance. Re-analysing the variables used by Diamond and Forrester yielded an AUC of 0.798, which increased to 0.890 by adding CTCS. For Pryor, Morise 1994, Morise 1997 and Shaw the AUC increased from 0.838 to 0.901, 0.831 to 0.899, 0.840 to 0.898 and 0.833 to 0.899. CTCS significantly improved model performance in each model. Validation demonstrated good diagnostic performance across all models. CTCS improves the prediction of the presence of obstructive CAD, independent of clinical predictors, and should be considered in its diagnostic work-up. (orig.)

  19. Incremental value of the CT coronary calcium score for the prediction of coronary artery disease

    International Nuclear Information System (INIS)

    Genders, Tessa S.S.; Pugliese, Francesca; Mollet, Nico R.; Meijboom, W. Bob; Weustink, Annick C.; Mieghem, Carlos A.G. van; Feyter, Pim J. de; Hunink, M.G.M.

    2010-01-01

    To validate published prediction models for the presence of obstructive coronary artery disease (CAD) in patients with new onset stable typical or atypical angina pectoris and to assess the incremental value of the CT coronary calcium score (CTCS). We searched the literature for clinical prediction rules for the diagnosis of obstructive CAD, defined as ≥50% stenosis in at least one vessel on conventional coronary angiography. Significant variables were re-analysed in our dataset of 254 patients with logistic regression. CTCS was subsequently included in the models. The area under the receiver operating characteristic curve (AUC) was calculated to assess diagnostic performance. Re-analysing the variables used by Diamond and Forrester yielded an AUC of 0.798, which increased to 0.890 by adding CTCS. For Pryor, Morise 1994, Morise 1997 and Shaw the AUC increased from 0.838 to 0.901, 0.831 to 0.899, 0.840 to 0.898 and 0.833 to 0.899. CTCS significantly improved model performance in each model. Validation demonstrated good diagnostic performance across all models. CTCS improves the prediction of the presence of obstructive CAD, independent of clinical predictors, and should be considered in its diagnostic work-up. (orig.)

  20. Vascular anastomosis by Argon Laser

    International Nuclear Information System (INIS)

    Gomes, O.M.; Macruz, R.; Armelin, E.; Brum, J.M.G.; Ribeiro, M.P.; Mnitentog, J.; Verginelli, G.; Pileggi, F.; Zerbini, E.J.

    1982-01-01

    Twenty four mongrel dogs, wheighing 13 to 24 kilograms were studied. After anesthesia, intubation and controlled ventilation, they were submitted to three types of vascular anastomosis: Group I - eight dogs with saphenous vein inter-carotid arteries by-pass: Group II - eight dogs with left mammary artery - left anterior descending coronary artery by-pass; Group III - eight dogs with venovenous anastomosis. In all groups 0.8 to 15 watts of Argon Laser power was applied to a total time of 90 to 300 seconds. The lower power for venovenous anastomosis and the greater for the arterial ones. The mean valves of resistence of the Laser anastomosis to pressure induced rupture was 730 mmHg in the immediate post operative study, and superior to 2.500 mmHg 30 days after. No signs of occlusion was demonstrated at the anastomosis sites by the angiographic and anathomo-patological study performed. (Author) [pt

  1. Assessment of coronary flow reserve by sestamibi imaging in patients with typical chest pain and normal coronary arteries

    International Nuclear Information System (INIS)

    Storto, Giovanni; Sorrentino, Anna R.; Pellegrino, Teresa; Liuzzi, Raffaele; Cuocolo, Alberto; Petretta, Mario

    2007-01-01

    We assessed coronary flow reserve (CFR) by sestamibi imaging in patients with typical chest pain, positive exercise stress test and normal coronary vessels. Thirty-five patients with typical chest pain and normal angiogram and 12 control subjects with atypical chest pain underwent dipyridamole/rest 99m Tc-sestamibi imaging. Myocardial blood flow (MBF) was estimated by measuring first transit counts in the pulmonary artery and myocardial counts from SPECT images. Estimated CFR was expressed as the ratio of stress to rest MBF. Rest MBF and CFR were corrected for rate-pressure product (RPP) and expressed as normalised MBF (MBF n ) and normalised CFR (CFR n ). Coronary vascular resistances (CVR) were calculated as the ratio between mean arterial pressure and estimated MBF. At rest, estimated MBF and MBF n were lower in controls than in patients (0.98 ± 0.4 vs 1.30 ± 0.3 counts/pixel/s and 1.14 ± 0.5 vs 1.64 ± 0.6 counts/pixel/s, respectively, both p n was still higher in controls than in patients (2.1 ± 0.5 vs 1.29 ± 0.5, p < 0.0001). At baseline, CVR values were lower (p < 0.01) in patients than in controls. Dipyridamole-induced changes in CVR were greater (p < 0.0001) in controls (-63%) than in patients (-35%). In the overall study population, a significant correlation between dipyridamole-induced changes in CVR and CFR was observed (r = -0.88, p < 0.0001). SPECT might represent a useful non-invasive method for assessing coronary vascular function in patients with angina and a normal coronary angiogram. (orig.)

  2. Quantitative relationship between coronary vasodilator reserve assessed by {sup 82}Rb PET imaging and coronary artery stenosis severity

    Energy Technology Data Exchange (ETDEWEB)

    Anagnostopoulos, Constantinos [Brigham and Women' s Hospital, Division of Nuclear Medicine/PET, Boston, MA (United States); Royal Brompton Hospital, Department of Nuclear Medicine, London (United Kingdom); Brigham and Women' s Hospital, Harvard Medical School, London (United Kingdom); Almonacid, Alexandra; Popma, Jeffrey J. [Brigham and Women' s Hospital, Division of Cardiovascular Medicine, Department of Medicine, Boston, MA (United States); Brigham and Women' s Hospital, Harvard Medical School, London (United Kingdom); El Fakhri, Georges [Brigham and Women' s Hospital, Division of Nuclear Medicine/PET, Boston, MA (United States); Royal Brompton Hospital, Department of Cardiology, London (United Kingdom); Curillova, Zelmira; Dorbala, Sharmila; Di Carli, Marcelo F. [Brigham and Women' s Hospital, Division of Nuclear Medicine/PET, Boston, MA (United States); Brigham and Women' s Hospital, Cardiovascular Imaging, Department of Radiology, Boston, MA (United States); Brigham and Women' s Hospital, Division of Cardiovascular Medicine, Department of Medicine, Boston, MA (United States); Brigham and Women' s Hospital, Harvard Medical School, London (United Kingdom); Sitek, Arkadiusz [Brigham and Women' s Hospital, Division of Nuclear Medicine/PET, Boston, MA (United States); Brigham and Women' s Hospital, Harvard Medical School, London (United Kingdom); Roughton, Michael [Royal Brompton Hospital, Department of Cardiology, London (United Kingdom)

    2008-09-15

    The relationship between myocardial blood flow (MBF) and stenosis severity has been determined previously using cyclotron-produced radiotracers such as {sup 15}O-H{sub 2}O and {sup 13}N-ammonia. An attractive alternative to overcome the limitations related to the use of cyclotron might be to use the generator-produced {sup 82}Rb as a flow tracer. The current study was undertaken to investigate the relationship between MBF and coronary vasodilator reserve (CVR) as measured by {sup 82}Rb positron emission tomography (PET) and the percent diameter stenosis as defined by quantitative coronary arteriography. We prospectively evaluated 22 individuals: 15 patients (60 {+-} 11 years of age) with angiographically documented coronary artery disease (CAD) and seven age-matched (56 {+-} 9 years) asymptomatic individuals without risk factors for CAD. Dynamic {sup 82}Rb PET was performed at rest and after dipyridamole vasodilation. MBF, CVR and an index of 'minimal coronary resistance' (MCR) were assessed in each of the three main coronary territories. Rest and stress MBF in regions subtended by vessels with less than 50% diameter stenosis was similar to that of the individuals with no risk factors for CAD. As a result, CVR was also similar in the two groups (1.9, interquartile [IQ] range from 1.7 to 2.7 vs. 2.2, IQ range from 2 to 3.4 respectively, p=0.09). CVR successfully differentiated coronary lesions with stenosis severity 70% to 89% from those with 50% to 69% stenosis (1, IQ range from 1 to 1.3 vs. 1.7, IQ range from 1.4 to 2), respectively, p=0.001. In addition, hyperaemic MBF (r{sup 2}=0.74, p<0.001), CVR (r {sup 2}=0.69, p<0.001) and MCR (r{sup 2}=0.78, p<0.001) measurements were inversely and non-linearly correlated to the percent diameter stenosis on angiography. MBF and CVR are inversely and non-linearly correlated to stenosis severity. Quantitative {sup 82}Rb PET can be a clinically useful tool for an accurate functional assessment of CAD. (orig.)

  3. High performance message passing for the ATLAS DAQ/EF-1 project

    CERN Document Server

    Mornacchi, Giuseppe

    1999-01-01

    Summary form only. A message passing library has been developed in the context of the ATLAS DAQ/EF-1 project. It is used for time critical applications within the front-end part of the DAQ system, mainly to exchange data control messages between I/O processors. Key objectives of the design were low message overheads, efficient use of the data transfer buses, provision of broadcast functionality and a hardware and operating system independent implementation of the application interface. The design and implementation of the message passing library are presented. As required by the project, the implementation is based on commercial components, namely VMEbus, PCI, the Lynx-OS real-time operating system and an additional inter- processor link, PVIC. The latter offers broadcast functionality identified as being important to the overall performance of the message passing. In addition, performance benchmarks for all implementing buses are presented for both simple test programs and the full DAQ applications. (0 refs)...

  4. Coronary anomalies in Pakistani children with tetralogy of fallot

    International Nuclear Information System (INIS)

    Hussain, I.; Patel, N.

    2010-01-01

    To determine coronary artery anomalies in tetralogy of Fallot in Pakistani children as seen on angiography. Study Design: Case series. Place and Duration of Study: The National Institute of Cardiovascular Diseases, Karachi, Pakistan from July 2006 to July 2007. Methodology: Children under 15 years of age with echocardiographic diagnosis of tetralogy of Fallot were included in the study. All patients had pre-operative cardiac catheterization and angiography. Coronary arteries were studied with a nonselective aortic root angiogram in standard cranially tilted left anterior oblique view. The frequency of a normal and an anomalous coronary was determined. Results: Of the 83 patients, 78% were male and had a mean age of 8.9 years. Their mean weight was 14.3 kilograms. Seventy six (91.6%) had a normal coronary anatomy while 7 (8.4%) patients had anomalous coronary arteries. Among the patients with coronary anomalies, the commonest was a single origin coronary artery in 04 (57.14%) cases. Three (42.86%) had an anomalous origin of left anterior descending artery from the right coronary artery. Conclusion: Coronary artery anomalies were detected in 8.4% of the cases with tetralogy of Fallot. Single origin coronary artery anomaly was the commonest anomaly. (author)

  5. Differences in coronary plaque composition with aging measured by coronary computed tomography angiography.

    Science.gov (United States)

    Tota-Maharaj, Rajesh; Blaha, Michael J; Rivera, Juan J; Henry, Travis S; Choi, Eue-Keun; Chang, Sung-A; Yoon, Yeonyee E; Chun, Eun Ju; Choi, Sang-Il; Blumenthal, Roger S; Chang, Hyuk-Jae; Nasir, Khurram

    2012-07-12

    Little is known about the independent impact of aging on coronary plaque morphology and composition in the era of cardiac computed tomography angiography (CCTA). We studied 1015 consecutive asymptomatic South Korean subjects (49 ± 10 years, 64% men) who underwent 64-slice CCTA during routine health evaluation. Coronary plaque characteristics were analyzed on a per-segment basis according to the modified AHA classification. Plaques with >50% calcified tissue were classified as calcified (CAP), plaques with NCAP). Multiple regression analysis was employed to describe the cross-sectional association between age tertile and plaque type burden (≥ 2 affected segments) after adjustment for other cardiovascular risk factors. The prevalence of coronary plaque increased with age, (1st tertile: 7.5%, 3rd tertile: 38.5% [pNCAP to overall plaque burden decreased with age from nearly 50% in the first tertile to approximately 20% in the third, while there was a reciprocal increase in both MCAP and CAP subtypes. In multivariable analysis, patients in the oldest tertile had a 2.5-fold increase in burden of NCAP, yet a nearly 40-fold increase in MCAP and 16-fold increase in CAP compared to the youngest tertile. In conclusion, CCTA is an effective method for measuring age-related differences in the burden of individual coronary plaque subtypes. Future research is needed to determine whether the increase in mixed and calcified plaques seen with aging produce an independent contribution to the age-related increase in cardiovascular risk. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  6. Preoperative Scale to Determine All-Cause Readmission After Coronary Artery Bypass Operations.

    Science.gov (United States)

    Zywot, Aleksander; Lau, Christine S M; Glass, Nina; Bonne, Stephanie; Hwang, Franchesca; Goodman, Koren; Mosenthal, Anne; Paul, Subroto

    2018-04-01

    Coronary artery bypass graft (CABG) operations are associated with all-cause readmission rates of approximately 15%. In attempts to reduce readmission rates, the Hospital Readmission Reduction Program expanded to include CABG operations in 2015. The aim of this study was therefore to develop a predictive readmission scale that would identify patients at higher risk of readmission after CABG using commonly available administrative data. Data of 126,519 patients from California and New York (derivation cohort) and 94,318 patients from Florida and Washington (validation cohort) were abstracted from the State Inpatient Database (2006 to 2011). The readmission after CABG scale was developed to predict 30-day readmission risk and was validated against a separate cohort. Thirty-day CABG readmission rates were 23% in the derivation cohort and 21% in the validation cohort. Predictive factors included older age, female gender (odds ratio [OR], 1.34), African American ethnicity (OR, 1.13), Medicare or Medicaid insurance, and comorbidities, including renal failure (OR, 1.56) and congestive heart failure (OR, 2.82). These were independently predictive of increased readmission rates (p readmission scale was then created with these preoperative factors. When applied to the validation cohort, it explained 98% of the readmission variability. The readmission after CABG scale reliably predicts a patient's 30-day CABG readmission risk. By identifying patients at high-risk for readmission before their procedure, risk reduction strategies can be implemented to reduce readmissions and healthcare expenditures. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  7. High frequency fishbone driven by passing energetic ions in tokamak plasmas

    Science.gov (United States)

    Wang, Feng; Yu, L. M.; Fu, G. Y.; Shen, Wei

    2017-05-01

    High frequency fishbone instability driven by passing energetic ions was first reported in the Princeton beta experiment with tangential neutral-beam-injection (Heidbrink et al 1986 Phys. Rev. Lett. 57 835-8). It could play an important role for ITER-like burning plasmas, where α particles are mostly passing particles. In this work, a generalized energetic ion distribution function and finite drift orbit width effect are considered to improve the theoretical model for passing particle driving fishbone instability. For purely passing energetic ions with zero drift orbit width, the kinetic energy δ {{W}k} is derived analytically. The derived analytic expression is more accurate as compared to the result of previous work (Wang 2001 Phys. Rev. Lett. 86 5286-8). For a generalized energetic ion distribution function, the fishbone dispersion relation is derived and is solved numerically. Numerical results show that broad and off-axis beam density profiles can significantly increase the beam ion beta threshold {βc} for instability and decrease mode frequency.

  8. Emergency coronary angioplasty with stenting using Cordis® diagnostic coronary catheters when there is difficulty in engaging guide catheters and bench evaluation of diagnostic and guide catheters.

    Science.gov (United States)

    Arokiaraj, Mark Christopher

    2018-02-01

    Difficulty in engaging with guide catheters is not uncommon in acute emergencies. We aimed to evaluate the use of Cordis ® INFINITI diagnostic catheters to perform angioplasty in patients in whom the coronaries cannot be engaged using standard guide catheters. In 34 cases of acute coronary syndrome, when difficulty in engagement with two standard guide catheters was encountered with reasonable manipulations, angioplasty was performed using diagnostic catheters. In total, 40 stents were placed by this technique. Pushability and trackability, distal tip flexion and three-point bending tests were performed to evaluate the performance of the guide and diagnostic catheters. Angioplasty was performed easily in a setting where it would have been very difficult to perform. Coronary dissection occurred in one patient, treated by a stent. The stent and dilatation balloons were easily passed through the diagnostic catheters. Pressure tracings were clearly preserved with certain stent delivery systems, and at angioplasty, although there was slightly reduced opacification of the respective artery, the coronary anatomy was sufficiently visualized to perform angioplasty. No periprocedural target lesion complications were seen in any cases. Pushability and trackability tests showed good force transmission along a tortuous path with diagnostic catheters, and balanced force-displacement curves from three-point bending tests and distal tip softness tests. Angioplasty with stenting can be performed safely through 6F Cordis ® infiniti diagnostic catheters when difficulty in engaging guide catheters is encountered. Copyright © 2018 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  9. Reduction of cognitive performance by piracetam in patients undergoing coronary bypass surgery using heart-lung maschine

    OpenAIRE

    Alaaraj, Nour

    2015-01-01

    Introduction: The occurrence of cognitive dysfunction after coronary bypass surgery poses a relevant clinical problem. The precise pathophysiological mechanisms underlying post-operative cognitive dysfunction remain to be fully elucidated. However, it seems safe to assume that the etiology is multifactorial. Piracetam is approved for the treatment of chronic cognitive dysfunction in dementia. Emerging data suggests that piracetam may also be beneficial for post-operative cognitive outcomes. T...

  10. Coronary flow reserve index corrected by exercise load using Tl-201 SPECT

    International Nuclear Information System (INIS)

    Kubota, Yasushi; Sugihara, Hiroki; Azuma, Akihiro

    1990-01-01

    For simple, non-invasive evaluation of coronary flow reserve during exercise, we investigated the coronary flow reserve index using the ratio of change of fractional distribution in the regional myocardium to oxygen demand. The subjects included 24 patients with effort angina pectoris and 11 normal volunteers. PTCA was peformed for 11 patients. Using the biological properties of Tl-201 single photon emission computed tomography (SPECT) was performed at submaximal exercise and at rest by two successive injections of Tl-201 within a short time interval (double dose method). The correlation between the fractional distribution in the myocardium (Δ-Fract) and the oxygen demand during exercise and at rest were evaluated. Δ-Fract correlated well with the rate of change of the pressure rate product (Δ-PRP), and Δ-Fract/Δ-PRP (CRI) was a good indicator of the coronary flow reserve index. CRI in the ischemic region correlated well with the percent area stenosis of the supplying coronary artery and improved with resolution of percent area stenosis of the target coronary artery after PTCA, but in some cases they were not above the normal range. CRI as obtained by exercise SPECT using the double dose method is useful for non-invasively estimating the coronary flow reserve during exercise, and it can be used for evaluating the effect before and after PTCA. (author)

  11. Impact on adenosine stress cardiac magnetic resonance for recanalisation and follow up of chronic total coronary occlusions

    Energy Technology Data Exchange (ETDEWEB)

    Heyne, J.P. [Institute of Diagnostic and Interventional Radiology, Friedrich Schiller University Jena, Erlanger Allee 101, D-07740 Jena (Germany)], E-mail: Jens-Peter.Heyne@med.uni-jena.de; Goernig, M. [Clinic for Internal Medicine I, Friedrich Schiller University Jena, Erlanger Allee 101, D-07740 Jena (Germany)], E-mail: Matthias.Goernig@med.uni-jena.de; Feger, J. [Institute of Diagnostic and Interventional Radiology, Friedrich Schiller University Jena, Erlanger Allee 101, D-07740 Jena (Germany)], E-mail: Joachim.Feger@email.de; Kurrat, C. [Institute of Diagnostic and Interventional Radiology, Friedrich Schiller University Jena, Erlanger Allee 101, D-07740 Jena (Germany)], E-mail: Claudia.Kurrat@med.uni-jena.de; Werner, G.S. [Clinic for Internal Medicine I, Friedrich Schiller University Jena, Erlanger Allee 101, D-07740 Jena (Germany)], E-mail: Gerald.Werner@Klinikum-Darmstadt.de; Figulla, H.R. [Clinic for Internal Medicine I, Friedrich Schiller University Jena, Erlanger Allee 101, D-07740 Jena (Germany)], E-mail: Hans.Figulla@med.uni-jena.de; Kaiser, W.A. [Institute of Diagnostic and Interventional Radiology, Friedrich Schiller University Jena, Erlanger Allee 101, D-07740 Jena (Germany)], E-mail: Werner.Kaiser@med.uni-jena.de

    2007-09-15

    Objective: To evaluate the impact on cardiac magnetic resonance imaging (CMRI) with adenosine stress and delayed enhancement for indication and follow up after interventional recanalisation of chronic total coronary occlusions (CTOs). Material and methods: Twenty consecutive patients (15 males; 5 females; mean age 65 years) with CTO verified by cardiac catheterisation referred to CMRI. Sixteen of them got CMRI before and after coronary recanalisation. Wall motion abnormalities (WMAs), first pass perfusion with adenosine and viability were assessed using a 1.5 T MR scanner (Sonata; Siemens). CMRI results were compared with clinical classifications, the results of cardiac catheterisation and follow up angiography. Results: Sixteen patients had a successful recanalisation, 15 of the occluded coronary artery and one of collateral donor artery stenosis. After recanalisation all stress-induced progressive or new wall motion abnormalities (WMAs) of the corresponding segments and in the collateral donor territory (5 patients) and all adenosine induced perfusion defects (PD) or delay (12 patients) were regredient. 13/16 patients showed no transmural and one patient transmural delayed enhancement (DE) indicating myocardial scar. In 10/16 patients CSS grading of angina improved after recanalisation. Conclusion: After successful recanalisation of CTOs, patients with preinterventional stress-induced PDs and WMAs in viable myocardium did not display any signs of stress-induced ischemia postinterventionally. A comprehensive CMRI approach, including assessment of rest and stress WMAs, first pass perfusion and myocardial viability represents an important tool for the pre-interventional decision to recanalise CTOs and follow up.

  12. Regenerative beam breakup in multi-pass electron accelerators

    International Nuclear Information System (INIS)

    Vetter, A.M. Jr.

    1980-01-01

    Important electron coincidence experiments in the 1 to 2 GeV range require electron beams of high intensity and high duty factor. To provide such beams, multi-pass electron accelerator systems are being developed at many laboratories. The beam current in multi-pass electron machines is limited by bean breakup which arises from interaction of the electron beam with deflection modes of the accelerator structure. Achieving high beam intensity (50 to 100 μA) will require detailed understanding and careful control of beam breakup phenomena, and is the subject of this thesis. The TM 11 -like traveling wave theory is applied to obtain a physical understanding of beam-mode interactions and the principles of focussing in simple two-pass systems, and is used as a basis for general studies of the dependence of starting current on accelerator parameters in systems of many passes. The concepts developed are applied in analyzing beam breakup in the superconducting recyclotron at Stanford. Measurements of beam interactions with selected breakup modes are incorporated in a simple model in order to estimate relative strengths of breakup modes and to predict starting currents in five-pass operation. The improvement over these predicted currents required in order to obtain 50 to 100 μA beams is shown to be achievable with a combination of increased breakup mode loading and improved beam optics

  13. Coronary artery calcification detected by a mobile helical CT unit in a mass screening. The frequency and relationship to coronary risk factors and coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Itani, Yasutaka; Watanabe, Shigeru; Masuda, Yoshiaki [Chiba Univ. (Japan). School of Medicine; Hanamura, Kazuhisa; Asakura, Kazuhiro; Sone, Shusuke; Sunami, Yuko; Shimura, Akimitsu; Miyamoto, Tadaaki

    2001-06-01

    A strong relationship is known to exist between coronary artery disease (CAD) and coronary artery calcification (CAC) detected by CT. In this study, we investigated the frequency of CAC and the relationship between coronary risk factors, CAD and CAC in a mass screening using a mobile helical CT unit. The total number of participants was 10008 people undergoing a medical examination for lung cancer and tuberculosis using a mobile helical CT unit. We measured the CT density of the coronary artery to detect CAC. The CT density threshold for determining CAC was above +110HU. The frequency of CAC was 16.0% in the overall patient population and significantly higher in males than in females (20.6% vs 10.7%). Frequency increased with age in both genders. Hypertension and diabetes mellitus were significantly related to CAC. Smoking showed a correlation with CAC only in males. A significant relationship was observed between CAD and CAC in males. In particular, the relationship between them was strongest in males under 60 years of age. Furthermore, the odds ratio of CAC in predicting CAD increased with increasing risk factors in both genders. (author)

  14. Factors influencing delay time and coronary arterial density during coronary angiography with DSCT.

    Science.gov (United States)

    Tang, Lijun; Zhu, Xiaomei; Xu, Yi; Yu, Tongfu; Xu, Hai; Tang, Jinhua; Dogra, Vikram; Wang, Dehang

    2011-02-01

    CT angiography (CTA) plays an important role in diagnosing coronary arterial disease. Delay time and density of the coronary arteries related with patient-specific factors are essential for getting an optimal CTA image. To investigate various factors influencing delay time and coronary arterial density during coronary CTA with dual source CT. One hundred and sixteen consecutive subjects who underwent cardiac DSCT with retrospective ECG-gating were included. Factors including gender, age, height, weight, transversal cardiac diameter (TCD), transversal thoracic diameter (TTD), heart rate (HR), body surface area (BSA = [weight × height/3600](1/2)) and cardiothoracic ratio (CTR = TCD/TTD) were recorded, measured and calculated before administration of contrast media during coronary CT angiography. Delay time was determined as duration from the beginning of the injection to the density in the descending aorta at the level of right main pulmonary artery reaching a threshold of 100 HU. Coronary arterial density was measured at the mid portion of the right coronary artery. Regression analysis and stepwise regression analysis were used to investigate the influence of these factors on delay time and coronary arterial density. Delay time decreased with an increasing HR and it was shorter in women than men. Delay time increased with an increasing TCD. Delay time could be predicted by the formula: DT = 16.651-0.110 × HR + 1.902 × gender + 0.394 × TCD (where DT is abbreviation for delay time, gender is 0 for women and 1 for men). Coronary arterial density decreased with an increasing HR and weight. Coronary arterial density could be predicted by the formula: CAD = 923.42-4.099 × HR-3.293 × weight (CAD = coronary arterial density). There was no relationship between the other factors mentioned above and delay time or coronary arterial density. Delay time is influenced by HR, gender and TCD. Coronary arterial density also changes with HR and weight. So HR, gender, TCD and

  15. Experimental analysis of humidification process by air passing through seawater

    International Nuclear Information System (INIS)

    El-Agouz, S.A.; Abugderah, M.

    2008-01-01

    An experimental investigation of humidification process by air passing through seawater is presented. The main objective of this work was to determine the humid air behaviour through single-stage of heating-humidifying processes. This experimental work studied the influence of the operating conditions such as the water temperature, the headwater difference, the air velocity and the inlet air temperature to evaporator chamber on the vapour content difference and humidification efficiency. Two cases of different inlet conditions of ambient and heated air cases are studied. The experimental results show that, the vapour content difference and the humidification efficiency of the system is strongly affected by the saline water temperature in the evaporator chamber, headwater difference and the air velocity. The inlet air temperature to evaporator chamber variation was found to have a small affect on the vapour content difference. The obtained maximum vapour content difference of the air was about 222 gr w /kg a at 75 deg. C for water and air. The obtained vapour content is high compared to that obtained in literature for single-stage and very similar for multi-stage

  16. Coronary Artery Bypass in Octogenarians

    Directory of Open Access Journals (Sweden)

    Chen-Yen Chien

    2012-09-01

    Full Text Available Prevalence of coronary artery disease (CAD has increased with the expansion of life span among the elderly population in the world. Hence, the issue of the coronary artery bypass in octogenarians has attracted more attention. Recent literature about the topic revealed nearly the same excellent results as those in the younger population under the newly developed operative techniques and improving concept in perioperative management and postoperative care. In this article, we review the current status of the procedure that was thought to be dangerous in the earlier era, including its risk factors, result, and benefit.

  17. Assessment of coronary artery disease by post-mortem cardiac MR

    International Nuclear Information System (INIS)

    Ruder, Thomas D.; Bauer-Kreutz, Regula; Ampanozi, Garyfalia; Rosskopf, Andrea B.; Pilgrim, Thomas M.; Weber, Oliver M.; Thali, Michael J.; Hatch, Gary M.

    2012-01-01

    Objectives: Minimally invasive or virtual autopsies are being advocated as alternative to traditional autopsy, but have limited abilities to detect coronary artery disease. It was the objective of this study to assess if the occurrence of chemical shift artifacts (CSA) along the coronary arteries on non-contrast, post-mortem cardiac MR may be used to investigate coronary artery disease. Methods: We retrospectively compared autopsy and CT findings of 30 cases with significant (≥75%), insignificant (<75%), or absent coronary artery stenosis to post-mortem cardiac MR findings. The chi-square test was used to investigate if the occurrence of CSA depends on the presence or absence of stenosis. Sensitivity, specificity and predictive values were calculated for each finding. Results: CSA indicates the absence of (significant) stenosis (p < 0.001). The occurrence of paired dark bands in lieu of CSA on post-mortem cardiac MR suggests (significant) coronary arteries stenosis (p < 0.001). Both findings have a high specificity but low sensitivity. Conclusions: CSA is a marker of vessel patency. The presence of paired dark bands indicates stenosis. These criteria improve the ability of minimally invasive or virtual autopsy to detect coronary artery disease related deaths

  18. The human coronary vasodilatory response to acute mental stress is mediated by neuronal nitric oxide synthase

    Science.gov (United States)

    Khan, Sitara G.; Melikian, Narbeh; Shabeeh, Husain; Cabaco, Ana R.; Martin, Katherine; Khan, Faisal; O’Gallagher, Kevin; Chowienczyk, Philip J.

    2017-01-01

    Mental stress-induced ischemia approximately doubles the risk of cardiac events in patients with coronary artery disease, yet the mechanisms underlying changes in coronary blood flow in response to mental stress are poorly characterized. Neuronal nitric oxide synthase (nNOS) regulates basal coronary blood flow in healthy humans and mediates mental stress-induced vasodilation in the forearm. However, its possible role in mental stress-induced increases in coronary blood flow is unknown. We studied 11 patients (6 men and 5 women, mean age: 58 ± 14 yr) undergoing elective diagnostic cardiac catheterization and assessed the vasodilator response to mental stress elicited by the Stroop color-word test. Intracoronary substance P (20 pmol/min) and isosorbide dinitrate (1 mg) were used to assess endothelium-dependent and -independent vasodilation, respectively. Coronary blood flow was estimated using intracoronary Doppler recordings and quantitative coronary angiography to measure coronary artery diameter. Mental stress increased coronary flow by 34 ± 7.0% over the preceding baseline during saline infusion (P coronary artery diameter by 6.9 ± 3.7% (P = 0.02) and 0.5 ± 2.8% (P = 0.51) in the presence of S-methyl-l-thiocitrulline. The response to substance P did not predict the response to mental stress (r2 = −0.22, P = 0.83). nNOS mediates the human coronary vasodilator response to mental stress, predominantly through actions at the level of coronary resistance vessels. NEW & NOTEWORTHY Acute mental stress induces vasodilation of the coronary microvasculature. Here, we show that this response involves neuronal nitric oxide synthase in the human coronary circulation. Listen to this article’s corresponding podcast at http://ajpheart.podbean.com/e/nnos-and-coronary-flow-during-mental-stress/. PMID:28646032

  19. The human coronary vasodilatory response to acute mental stress is mediated by neuronal nitric oxide synthase.

    Science.gov (United States)

    Khan, Sitara G; Melikian, Narbeh; Shabeeh, Husain; Cabaco, Ana R; Martin, Katherine; Khan, Faisal; O'Gallagher, Kevin; Chowienczyk, Philip J; Shah, Ajay M

    2017-09-01

    Mental stress-induced ischemia approximately doubles the risk of cardiac events in patients with coronary artery disease, yet the mechanisms underlying changes in coronary blood flow in response to mental stress are poorly characterized. Neuronal nitric oxide synthase (nNOS) regulates basal coronary blood flow in healthy humans and mediates mental stress-induced vasodilation in the forearm. However, its possible role in mental stress-induced increases in coronary blood flow is unknown. We studied 11 patients (6 men and 5 women, mean age: 58 ± 14 yr) undergoing elective diagnostic cardiac catheterization and assessed the vasodilator response to mental stress elicited by the Stroop color-word test. Intracoronary substance P (20 pmol/min) and isosorbide dinitrate (1 mg) were used to assess endothelium-dependent and -independent vasodilation, respectively. Coronary blood flow was estimated using intracoronary Doppler recordings and quantitative coronary angiography to measure coronary artery diameter. Mental stress increased coronary flow by 34 ± 7.0% over the preceding baseline during saline infusion ( P stress increased coronary artery diameter by 6.9 ± 3.7% ( P = 0.02) and 0.5 ± 2.8% ( P = 0.51) in the presence of S -methyl-l-thiocitrulline. The response to substance P did not predict the response to mental stress ( r 2 = -0.22, P = 0.83). nNOS mediates the human coronary vasodilator response to mental stress, predominantly through actions at the level of coronary resistance vessels. NEW & NOTEWORTHY Acute mental stress induces vasodilation of the coronary microvasculature. Here, we show that this response involves neuronal nitric oxide synthase in the human coronary circulation.Listen to this article's corresponding podcast at http://ajpheart.podbean.com/e/nnos-and-coronary-flow-during-mental-stress/. Copyright © 2017 the American Physiological Society.

  20. Assessment of myocardial collateral circulation by intracoronary injection of radioactive microspheres and selective coronary angiography

    International Nuclear Information System (INIS)

    Uhde, W.

    1986-01-01

    In 46 patients selective coronary angiography was performed followed by selective coronary perfusion scintigraphy and a comparative assessment was made of the contralateral coronary collateral circulation. Intracoronary injection of radioactively marked imcrospheres resulted in the detection of microcirculatory processes and made it possible to evaluate the relative efficiency of coronary collaterals. This in turn meant a low-risk supplement and extension of the findings of coronary angiography. This holds particularly true for the area of the left ventricular myocardium. (author)

  1. Percutaneous coronary intervention versus coronary-artery bypass grafting for severe coronary artery disease

    NARCIS (Netherlands)

    P.W.J.C. Serruys (Patrick); M-C. Morice (Marie-Claude); A.P. Kappetein (Arie Pieter); A. Colombo (Antonio); D.R. Holmes Jr (David); M.J. Mack (Michael); E. Stahle (Elisabeth); T.E. Feldman (Ted); M.J.B.M. van den Brand (Marcel); E.J. Bass (Eric); N. van Dyck (Nic); K. Leadly (Katrin); K.D. Dawkins (Keith); F.W. Mohr (Friedrich)

    2009-01-01

    textabstractBACKGROUND Percutaneous coronary intervention (PCI) involving drug-eluting stents is increasingly used to treat complex coronary artery disease, although coronary-artery bypass grafting (CABG) has been the treatment of choice historically. Our trial compared PCI and CABG for treating

  2. Coronary artery bypass grafting without cardiopulmonary bypass and without interruption of native coronary flow using a novel anastomosis site restraining device ("Octopus").

    Science.gov (United States)

    Borst, C; Jansen, E W; Tulleken, C A; Gründeman, P F; Mansvelt Beck, H J; van Dongen, J W; Hodde, K C; Bredée, J J

    1996-05-01

    This study assessed the feasibility of coronary artery bypass grafting on the beating heart without interruption of native coronary blood flow using a novel anastomosis site restraining device. Recently, an end-to-side bypass technique was described that does not require interruption of flow in the recipient artery. By means of a suction device ("Octopus"), in 31 pigs the epicardium was grasped and immobilized through an arm contraption fixed to the operating table. In the first 15 consecutive pigs (study I), the two-dimensional motion of an epicardial beacon was monitored. In 16 subsequent pigs (study II), an internal mammary artery was grafted under the microscope in two steps to a proximal coronary artery segment, without cardiopulmonary bypass. First, the internal mammary artery was sutured end-to-side to the outside of the coronary artery. Secondly, an orifice was punched in the partitioning coronary wall by an excimer laser catheter introduced through a temporary side-branch of the internal mammary artery. Study II: During 43 suction periods in four anastomosis areas, immobilization was achieved for 15 to 169 min (>30 h in total) in 13 open- and 9 closed-chest procedures without hemodynamic deterioration. The area circumscribed by the edges of the beacon trajectory (area in which the anastomosis is to be tracked) was reduced from 73.0 +/- 43.0 mm(2) (mean +/- SD) to 1.3 +/- 0.5 mm(2) (p<0.001) in the open-chest and to 0.2 +/- 0.2 mm(2) in the closed-chest procedure. At 6 weeks, no myocardial or coronary suction lesions were found. Study II: Nonocclusive anastomosis surgery required 25 +/- 3 min. No leakage, serious arrhythmias, graft closure or hemodynamic deterioration occurred during the procedure or for 2 h after ligating the coronary artery proximally. At 6 weeks, all seven grafts were patent. Coronary bypass on the beating heart without interruption of coronary flow is feasible. In both open- and in closed-chest procedures, the "Octopus" reduced

  3. Periodontal disease, tooth loss and coronary heart disease assessed by coronary angiography: a cross-sectional observational study.

    Science.gov (United States)

    Zanella, S M; Pereira, S S; Barbisan, J N; Vieira, L; Saba-Chujfi, E; Haas, A N; Rösing, C K

    2016-04-01

    To evaluate the association between periodontal disease, tooth loss and coronary heart disease (CHD). There is still controversy about the relationship between periodontal disease and tooth loss with vessel obstruction assessed using coronary angiography. This cross-sectional study included 195 patients that underwent coronary angiography and presented with at least six teeth. Patients were classified into three categories of coronary obstruction severity: absence; one or more vessels with ≤ 50% obstruction; and one or more vessels with ≥ 50% obstruction. The extent of coronary obstruction was dichotomized into 0 and ≥ 1 affected vessels. A periodontist blinded to patient CHD status conducted a full mouth examination to determine mean clinical attachment loss, mean periodontal probing depth and tooth loss. Multiple logistic regression models were applied adjusting for age, gender, hypertension, smoking, body mass index, low-density lipoprotein cholesterol and C-reactive protein. Most patients were males (62.1%) older than 60 years (50.8%), and 61% of them had CHD. Mean periodontal probing depth, clinical attachment loss and tooth loss were 2.64 ± 0.72 mm, 4.40 ± 1.31 mm and 12.50 ± 6.98 teeth respectively. In the multivariable models, tooth loss was significantly associated with a higher chance of having at least one obstructed vessel (odds ratio = 1.04; 95% confidence interval 1.01-1.09) and with vessel obstruction ≥ 50% (odds ratio = 1.06; 95% confidence interval 1.01-1.11). No significant associations were found between periodontal variables and vessel obstruction. Tooth loss was found to be a risk indicator for CHD. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. [As cardioprotective and angiogenic biomarker, can ghrelin predict coronary collateral development and severity of coronary atherosclerosis?

    Science.gov (United States)

    Akboğa, Mehmet Kadri; Taçoy, Gülten; Yılmaz Demirtaş, Canan; Türkoğlu, Sedat; Boyacı, Bülent; Çengel, Atiye

    2017-06-01

    Ghrelin exerts protective effects on cardiovascular system by inhibiting progression of atherosclerosis, supression of vascular inflammation, and stimulating angiogenesis. Thus, the aim of this study was to investigate the effect of serum ghrelin on coronary collateral development and SYNTAX score in patients with severe coronary artery disease. Total of 91 patients who had ≥90% stenosis in at least one major coronary artery were prospectively included in this cross-sectional, observational study. Collateral degree was graded according to Rentrop-Cohen classification. Patients with grade 2 or 3 collateral degree were allocated to Good Collateral Group and patients with grade 0 or 1 collateral degree were included in Poor Collateral Group. Ghrelin and vascular endothelial growth factor A (VEGF-A) levels were measured using radioimmunoassay and ELISA kits. Serum ghrelin and VEGF-A levels were significantly higher in Good Collateral Group. Furthermore, ghrelin level showed significant inverse correlation with SYNTAX score (r=0.348; p=0.001). In multivariable regression analysis, ghrelin (Odds ratio, 1.013; 95% confidence interval, 1.011-1.017; p=0.013), VEGF-A, fasting plasma glucose and presence of chronic total occlusion were independent predictors of good collateral development. In receiver operating characteristic curve analysis, ghrelin value cut-off point of ≥781 pg/mL predicted good collateral development with sensitivity of 73.1% and specificity of 67.7%. Findings suggested that ghrelin has antioxidant and antiinflammatory properties that protect endothelial functions and also stimulate angiogenesis, which results in development of good coronary collateral and inhibition of progression of coronary atherosclerosis.

  5. Factors associated with coronary artery disease progression assessed by serial coronary computed tomography angiography

    International Nuclear Information System (INIS)

    Camargo, Gabriel Cordeiro; Gottlieb, Ilan; Rothstein, Tamara; Derenne, Maria Eduarda; Sabioni, Leticia; Lima, Ronaldo de Souza Leão; Lima, João A. C.

    2017-01-01

    Background: Coronary computed tomography angiography (CCTA) allows for noninvasive coronary artery disease (CAD) phenotyping. Factors related to CAD progression are epidemiologically valuable. Objective: To identify factors associated with CAD progression in patients undergoing sequential CCTA testing. Methods: We retrospectively analyzed 384 consecutive patients who had at least two CCTA studies between December 2005 and March 2013. Due to limitations in the quantification of CAD progression, we excluded patients who had undergone surgical revascularization previously or percutaneous coronary intervention (PCI) between studies. CAD progression was defined as any increase in the adapted segment stenosis score (calculated using the number of diseased segments and stenosis severity) in all coronary segments without stent (in-stent restenosis was excluded from the analysis). Stepwise logistic regression was used to assess variables associated with CAD progression. Results: From a final population of 234 patients, a total of 117 (50%) had CAD progression. In a model accounting for major CAD risk factors and other baseline characteristics, only age (odds ratio [OR] 1.04, 95% confidence interval [95%CI] 1.01–1.07), interstudy interval (OR 1.03, 95%CI 1.01–1.04), and past PCI (OR 3.66, 95%CI 1.77–7.55) showed an independent relationship with CAD progression. Conclusions: A history of PCI with stent placement was independently associated with a 3.7-fold increase in the odds of CAD progression, excluding in-stent restenosis. Age and interstudy interval were also independent predictors of progression. (author)

  6. Factors associated with coronary artery disease progression assessed by serial coronary computed tomography angiography

    Energy Technology Data Exchange (ETDEWEB)

    Camargo, Gabriel Cordeiro; Gottlieb, Ilan, E-mail: ilangottlieb@gmail.com [Casa de Saúde São José, Rio de Janeiro, RJ (Brazil); Rothstein, Tamara; Derenne, Maria Eduarda; Sabioni, Leticia; Lima, Ronaldo de Souza Leão [Centro de Diagnóstico por Imagem CDPI, Rio de Janeiro, RJ (Brazil); Lima, João A. C. [Johns Hopkins University, Baltimore (United States)

    2017-05-15

    Background: Coronary computed tomography angiography (CCTA) allows for noninvasive coronary artery disease (CAD) phenotyping. Factors related to CAD progression are epidemiologically valuable. Objective: To identify factors associated with CAD progression in patients undergoing sequential CCTA testing. Methods: We retrospectively analyzed 384 consecutive patients who had at least two CCTA studies between December 2005 and March 2013. Due to limitations in the quantification of CAD progression, we excluded patients who had undergone surgical revascularization previously or percutaneous coronary intervention (PCI) between studies. CAD progression was defined as any increase in the adapted segment stenosis score (calculated using the number of diseased segments and stenosis severity) in all coronary segments without stent (in-stent restenosis was excluded from the analysis). Stepwise logistic regression was used to assess variables associated with CAD progression. Results: From a final population of 234 patients, a total of 117 (50%) had CAD progression. In a model accounting for major CAD risk factors and other baseline characteristics, only age (odds ratio [OR] 1.04, 95% confidence interval [95%CI] 1.01–1.07), interstudy interval (OR 1.03, 95%CI 1.01–1.04), and past PCI (OR 3.66, 95%CI 1.77–7.55) showed an independent relationship with CAD progression. Conclusions: A history of PCI with stent placement was independently associated with a 3.7-fold increase in the odds of CAD progression, excluding in-stent restenosis. Age and interstudy interval were also independent predictors of progression. (author)

  7. Inversion prepared coronary MR angiography: direct visualization of coronary blood flow

    International Nuclear Information System (INIS)

    Katoh, M.; Spuentrup, E.; Buecker, A.; Guenther, R.W.; Stuber, M.; Manning, W.J.; Botnar, R.M.

    2005-01-01

    Purpose: visualization of coronary blood flow by means of a slice-selective inversion pre-pulse in concert with bright-blood coronary MRA. Materials and methods: coronary magnetic resonance angiography (MRA) of the right coronary artery (RCA) was performed in eight healthy adult subjects on a 1.5 Tesla MR system (Gyroscan ACS-NT, Philips Medical Systems, Best, NL) using a free-breathing navigator-gated and cardiac-triggered 3D steady-state free-precession (SSFP) sequence with radial k-space sampling. Imaging was performed with and without a slice-selective inversion pre-pulse, which was positioned along the main axis of the coronary artery but perpendicular to the imaging volume. Objective image quality parameters such as SNR, CNR, maximal visible vessel length, and vessel border definition were analyzed. Results: in contrast to conventional bright-blood 3D coronary MRA, the selective inversion pre-pulse provided a direct measure of coronary blood flow. In addition, CNR between the RCA and right ventricular blood pool was increased and the vessels had a tendency towards better delineation. Blood SNR and CNR between right coronary blood and epicardial fat were comparable in both sequences. (orig.)

  8. Performance of single-pass and by-pass multi-step multi-soil-layering systems for low-(C/N)-ratio polluted river water treatment.

    Science.gov (United States)

    Wei, Cai-Jie; Wu, Wei-Zhong

    2018-09-01

    Two kinds of hybrid two-step multi-soil-layering (MSL) systems loaded with different filter medias (zeolite-ceramsite MSL-1 and ceramsite-red clay MSL-2) were set-up for the low-(C/N)-ratio polluted river water treatment. A long-term pollutant removal performance of these two kinds of MSL systems was evaluated for 214 days. By-pass was employed in MSL systems to evaluate its effect on nitrogen removal enhancement. Zeolite-ceramsite single-pass MSL-1 system owns outstanding ammonia removal capability (24 g NH 4 + -Nm -2 d -1 ), 3 times higher than MSL-2 without zeolite under low aeration rate condition (0.8 × 10 4  L m -2 .h -1 ). Aeration rate up to 1.6 × 10 4  L m -2 .h -1 well satisfied the requirement of complete nitrification in first unit of both two MSLs. However, weak denitrification in second unit was commonly observed. By-pass of 50% influent into second unit can improve about 20% TN removal rate for both MSL-1 and MSL-2. Complete nitrification and denitrification was achieved in by-pass MSL systems after addition of carbon source with the resulting C/N ratio up to 2.5. The characters of biofilms distributed in different sections inside MSL-1 system well illustrated the nitrogen removal mechanism inside MSL systems. Two kinds of MSLs are both promising as an appealing nitrifying biofilm reactor. Recirculation can be considered further for by-pass MSL-2 system to ensure a complete ammonia removal. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. A New One-Pass Transformation into Monadic Normal Form

    DEFF Research Database (Denmark)

    Danvy, Olivier

    2003-01-01

    We present a translation from the call-by-value λ-calculus to monadic normal forms that includes short-cut boolean evaluation. The translation is higher-order, operates in one pass, duplicates no code, generates no chains of thunks, and is properly tail recursive. It makes a crucial use of symbolic...

  10. Coronary artery aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Koischwitz, D.; Harder, T.; Schuppan, U.; Thurn, P.

    1982-04-01

    Seven saccular coronary artery aneurysms have been demonstrated in the course of 1452 selective coronary artery angiograms. In six patients they were arterio-sclerotic; in one patient the aneurysm must have been congenital or of mycotic-embolic origin. The differential diagnosis between true aneurysms and other causes of vascular dilatation is discussed. Coronary artery aneurysms have a poor prognosis because of the possibility of rupture with resultant cardiac tamponade, or the development of thrombo-embolic myocardial infarction. These aneurysms can only be diagnosed by means of coronary angiography and require appropriate treatment.

  11. Roles of myocardial blood volume and flow in coronary artery disease: an experimental MRI study at rest and during hyperemia

    International Nuclear Information System (INIS)

    McCommis, Kyle S.; Goldstein, Thomas A.; Pilgram, Thomas; Abendschein, Dana R.; Misselwitz, Bernd; Gropler, Robert J.; Zheng, Jie

    2010-01-01

    To validate fast perfusion mapping techniques in a setting of coronary artery stenosis, and to further assess the relationship of absolute myocardial blood volume (MBV) and blood flow (MBF) to global myocardial oxygen demand. A group of 27 mongrel dogs were divided into 10 controls and 17 with acute coronary stenosis. On 1.5-T MRI, first-pass perfusion imaging with a bolus injection of a blood-pool contrast agent was performed to determine myocardial perfusion both at rest and during either dipyridamole-induced vasodilation or dobutamine-induced stress. Regional values of MBF and MBV were quantified by using a fast mapping technique. Color microspheres and 99m Tc-labeled red blood cells were injected to obtain respective gold standards. Microsphere-measured MBF and 99m Tc-measured MBV reference values correlated well with the MR results. Given the same changes in MBF, changes in MBV are twofold greater with dobutamine than with dipyridamole. Under dobutamine stress, MBV shows better association with total myocardial oxygen demand than MBF. Coronary stenosis progressively reduced this association in the presence of increased stenosis severity. MR first-pass perfusion can rapidly estimate regional MBF and MBV. Absolute quantification of MBV may add additional information on stenosis severity and myocardial viability compared with standard qualitative clinical evaluations of myocardial perfusion. (orig.)

  12. Roles of myocardial blood volume and flow in coronary artery disease: an experimental MRI study at rest and during hyperemia

    Science.gov (United States)

    McCommis, Kyle S.; Goldstein, Thomas A.; Abendschein, Dana R.; Misselwitz, Bernd; Pilgram, Thomas; Gropler, Robert J.

    2010-01-01

    Objective To validate fast perfusion mapping techniques in a setting of coronary artery stenosis, and to further assess the relationship of absolute myocardial blood volume (MBV) and blood flow (MBF) to global myocardial oxygen demand. Methods A group of 27 mongrel dogs were divided into 10 controls and 17 with acute coronary stenosis. On 1.5-T MRI, first-pass perfusion imaging with a bolus injection of a blood-pool contrast agent was performed to determine myocardial perfusion both at rest and during either dipyridamole-induced vasodilation or dobutamine-induced stress. Regional values of MBF and MBV were quantified by using a fast mapping technique. Color microspheres and 99mTc-labeled red blood cells were injected to obtain respective gold standards. Results Microsphere-measured MBF and 99mTc-measured MBV reference values correlated well with the MR results. Given the same changes in MBF, changes in MBV are twofold greater with dobutamine than with dipyridamole. Under dobutamine stress, MBV shows better association with total myocardial oxygen demand than MBF. Coronary stenosis progressively reduced this association in the presence of increased stenosis severity. Conclusions MR first-pass perfusion can rapidly estimate regional MBF and MBV. Absolute quantification of MBV may add additional information on stenosis severity and myocardial viability compared with standard qualitative clinical evaluations of myocardial perfusion. PMID:20182731

  13. In vitro evaluation of 56 coronary artery stents by 256-slice multi-detector coronary CT

    International Nuclear Information System (INIS)

    Steen, Henning; Andre, Florian; Korosoglou, Grigorios; Mueller, Dirk; Hosch, Waldemar; Kauczor, Hans-Ulrich; Giannitsis, Evangelos; Katus, Hugo A.

    2011-01-01

    Objective: We sought to investigate stent lumen visibility of 56 coronary stents with the newest 256-multi-slice-CT (256-MDCT) technology for different reconstruction algorithms in an in vitro model. Background: Early identification of in-stent restenosis (ISR) is important to avoid recurrent ischemia and prevent acute myocardial infarction (AMI). Since angiography has the disadvantage of high costs and its invasiveness, MDCT could be a convenient and safe non-invasive alternative for detection of ISR. Material and methods: Percentages of in-stent lumen diameter and in-stent signal attenuation (measured as contrast-to-noise ratio (CNR)) of 56 coronary stents (group A ≤2.5 mm; group B = 2.75-3.0 mm; group C = 3.5-4.0 mm) were evaluated in a coronary vessel in vitro phantom (iodine-filled plastic tubes) employing four different reconstruction algorithms (XCD, CC, CD, XCB) on a novel 256-MDCT (Philips-iCT, collimation = 128 mm x 0.625 mm; rotation time = 270 ms; tube current = 800 mA s with 120 kV). Analysis was conducted with the semi-automatical full-width-at-half-maximum (FWHM) method. P-values 60% for group C stents was significantly larger and CNR was significantly lower (both p 3.0 mm when analysed with cardio-dedicated sharp kernels, although clinical studies corroborating this claim should be performed. However, stents ≤3.0 mm reconstructed by soft kernels revealed insufficient in-stent lumen visualisation and should not be used in clinical practice. Further improvements in spatial and temporal image resolution as well as reductions of radiation exposure and image noise have to be accomplished for the ambitious goal of characterising both CT coronary artery anatomy and in-stent lumen.

  14. Accurate determination of high-risk coronary lesion type by multidetector cardiac computed tomography.

    Science.gov (United States)

    Alasnag, Mirvat; Umakanthan, Branavan; Foster, Gary P

    2008-07-01

    Coronary arteriography (CA) is the standard method to image coronary lesions. Multidetector cardiac computerized tomography (MDCT) provides high-resolution images of coronary arteries, allowing a noninvasive alternative to determine lesion type. To date, no studies have assessed the ability of MDCT to categorize coronary lesion types. The objective of this study was to determine the accuracy of lesion type categorization by MDCT using CA as a reference standard. Patients who underwent both MDCT and CA within 2 months of each other were enrolled. MDCT and CA images were reviewed in a blinded fashion. Lesions were categorized according to the SCAI classification system (Types I-IV). The origin, proximal and middle segments of the major arteries were analyzed. Each segment comprised a data point for comparison. Analysis was performed using the Spearman Correlation Test. Four hundred eleven segments were studied, of which 110 had lesions. The lesion distribution was as follows: 35 left anterior descending (LAD), 29 circumflex (Cx), 31 right coronary artery (RCA), 2 ramus intermedius, 8 diagonal, 4 obtuse marginal and 2 left internal mammary arteries. Correlations between MDCT and CA were significant in all major vessels (LAD, Cx, RCA) (p < 0.001). The overall correlation coefficient was 0.67. Concordance was strong for lesion Types II-IV (97%) and poor for Type I (30%). High-risk coronary lesion types can be accurately categorized by MDCT. This ability may allow MDCT to play an important noninvasive role in the planning of coronary interventions.

  15. Plaque disruption by coronary computed tomographic angiography in stable patients vs. acute coronary syndrome: a feasibility study.

    Science.gov (United States)

    Bilolikar, Abhay N; Goldstein, James A; Madder, Ryan D; Chinnaiyan, Kavitha M

    2016-03-01

    This study was designed to determine whether coronary CT angiography (CTA) can detect features of plaque disruption in clinically stable patients and to compare lesion prevalence and features between stable patients and those with acute coronary syndrome (ACS). We retrospectively identified patients undergoing CTA, followed by invasive coronary angiography (ICA) within 60 days. Quantitative 3-vessel CTA lesion analysis was performed on all plaques ≥25% stenosis to assess total plaque volume, low attenuation plaque (LAP, disruption, including ulceration and intra-plaque dye penetration (IDP). ICA was employed as a reference standard for disruption. A total of 145 (94 ACS and 51 stable) patients were identified. By CTA, plaque disruption was evident in 77.7% of ACS cases. Although more common among those with ACS, CTA also detected plaque disruption in 37.3% of clinically stable patients (P disruption as determined by CTA. Though the prevalence of plaque disruption is less than patients with ACS, these findings support the concept that some clinically stable patients may harbour 'silent' disrupted plaques. These findings may have implications for detection of 'at risk' plaques and patients. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  16. Factors influencing delay time and coronary arterial density during coronary angiography with DSCT

    International Nuclear Information System (INIS)

    Lijun Tang; Xiaomei Zhu; Yi Xu; Tongfu Yu; Hai Xu; Jinhua Tang; Dehang Wang; Dogra, Vikram

    2011-01-01

    Background: CT angiography (CTA) plays an important role in diagnosing coronary arterial disease. Delay time and density of the coronary arteries related with patient-specific factors are essential for getting an optimal CTA image. Purpose: To investigate various factors influencing delay time and coronary arterial density during coronary CTA with dual source CT. Material and Methods: One hundred and sixteen consecutive subjects who underwent cardiac DSCT with retrospective ECG-gating were included. Factors including gender, age, height, weight, transversal cardiac diameter (TCD), transversal thoracic diameter (TTD), heart rate (HR), body surface area (BSA = [weight x height/3600]1/2) and cardiothoracic ratio (CTR = TCD/TTD) were recorded, measured and calculated before administration of contrast media during coronary CT angiography. Delay time was determined as duration from the beginning of the injection to the density in the descending aorta at the level of right main pulmonary artery reaching a threshold of 100 HU. Coronary arterial density was measured at the mid portion of the right coronary artery. Regression analysis and stepwise regression analysis were used to investigate the influence of these factors on delay time and coronary arterial density. Results: Delay time decreased with an increasing HR and it was shorter in women than men. Delay time increased with an increasing TCD. Delay time could be predicted by the formula: DT = 16.651-0.110 x HR + 1.902 x gender + 0.394 x TCD (where DT is abbreviation for delay time, gender is 0 for women and 1 for men). Coronary arterial density decreased with an increasing HR and weight. Coronary arterial density could be predicted by the formula: CAD = 923.42-4.099 x HR-3.293 x weight (CAD = coronary arterial density). There was no relationship between the other factors mentioned above and delay time or coronary arterial density. Conclusion: Delay time is influenced by HR, gender and TCD. Coronary arterial density

  17. Redesign of emergency water supply system by-pass line from Cernavoda NPP Unit 1 and 2 using self regulating valves

    International Nuclear Information System (INIS)

    Tenescu, Mircea; Bigu, Melania; Nita, Iulian Pavel

    2010-01-01

    In this paper one considered improving the EWS (emergency water supply system) by-pass line in order to replace current manual operated valve with an self operated valve. This change is necessary in order to reduce the human error events in operation of the system in case of a DBE (design basis earthquake). The paper describes a theoretical and practical operation of a system using self regulating flow rate valves. Basically, the elimination of a possible human error in operating a system is important for nuclear safety in case of a DBE because it makes it avoidable in normal reactor cooling systems. The paper describes checking of the functioning of this equipment in operating conditions, investigating how it responds to various operating regimes. (authors)

  18. Notational analysis on tactical passing skills used by collegiate ...

    African Journals Online (AJOL)

    Notational analysis on tactical passing skills used by collegiate players in an indoor hockey masum tournament. K.N. Hasnor, H Hizan, M.I. Shahril, N.A. Kosni, M.R. Abdullah, A.B.H.M. Maliki, S.M. Mat-Rasid ...

  19. Coronary Anomaly and Coronary Artery Fistula as Cause of Angina Pectoris with Literature Review

    Directory of Open Access Journals (Sweden)

    Jayanth Koneru

    2011-01-01

    Full Text Available Coronary artery fistulas are rare anomalies of the coronary arteries that may sometimes cause symptoms by shunting blood flow away from the myocardial capillary network. We report the case of a 46-year old lady which shows the right coronary cusp giving rise to left main coronary artery called anomalous origin of a coronary artery (AOCA, and also a fistula between the left coronary artery and pulmonary artery. We describe our diagnostic approach and review the literature on the epidemiology, pathophysiology, the diagnostic modalities, and treatment options.

  20. Cirsoid Aneurysm of Coronary Arteries Associated with Arterioventricular Fistula Evaluated by 64-Multidetector CT Coronary Angiography: Depiction of a Case

    International Nuclear Information System (INIS)

    Marrone, Gianluca; Mamone, Giuseppe; Milazzo, Mariapina; Caruso, Settimo; Baravoglia, Cesar Hernandez; Vitulo, Patrizio; Gridelli, Bruno; Luca, Angelo

    2009-01-01

    A female patient with severe pulmonary hypertension was admitted for lung transplant evaluation. As an incidental finding, the chest CT showed diffuse and dilated coronaries, not detected at previous echocardiography. A coronary CT angiography was then performed using a 64-multidetector computed tomography (MDCT) scanner to better evaluate the coronary tree. The images obtained after postprocessing demonstrated tremendously aneurysmatic and tortuous coronary arteries and the presence of a septal branch deepening into the myocardium and penetrating the right ventricle cavity, forming an abnormal arterioventricular fistula. A causal relation between the aneurysms and the fistula is suspected.

  1. Anomalous origin of left coronary artery arising from the right coronary cusp presenting with chest discomfort and syncope on physical exercise

    Directory of Open Access Journals (Sweden)

    Ran Baik

    2010-02-01

    Full Text Available Anomalous origins of coronary arteries are a rare type of disease among children. These anomalies can be categorized into 3 types according to the anatomical relationship of the aorta and pulmonary trunks. Among these types, the interarterial type, as observed in our case, needs early diagnosis and treatment, because it can increase the risk for the patient, causing sudden cardiac death in young individuals. Although there are controversies concerning the management of anomalous origins of the left coronary artery (LCA in children, the result can be very beneficial, if treated accurately. Three well-known methods for correction of anomalous origins of LCA are re-implantation, coronary arterial bypass grafting (CABG, and unroofing. We report on the case of a 12-year-old girl who had chest discomfort and syncope with physical exercise and was later diagnosed with an anomalous origin of LCA by transthoracic echocardiography (TTE and heart computed tomography (CT. She underwent a corrective operation by re-implantation, CABG, and unroofing.

  2. Development of Coronary Pulse Wave Velocity: New Pathophysiological Insight Into Coronary Artery Disease.

    Science.gov (United States)

    Harbaoui, Brahim; Courand, Pierre-Yves; Cividjian, Andrei; Lantelme, Pierre

    2017-02-02

    Although aortic stiffness assessed by pulse wave velocity (PWV) is a strong predictor of coronary artery disease, the significance of local coronary stiffness has never been tackled. The first objective of this study was to describe a method of measuring coronary PWV (CoPWV) invasively and to describe its determinants. The second objective was to assess both CoPWV and aortic PWV in patients presenting with acute coronary syndromes or stable coronary artery disease. In 53 patients, CoPWV was measured from the delay in pressure wave and distance traveled as a pressure wire was withdrawn from the distal to the proximal coronary segment. Similarly, aortic PWV was measured invasively when the wire was pulled across the ascending aorta; carotid-femoral PWV was also measured noninvasively using the SphygmoCor system (AtCor Medical). Mean CoPWV was 10.3±6.1 m/s. Determinants of increased CoPWV were fractional flow reserve, diastolic blood pressure, and previous stent implantation in the recorded artery. CoPWV was lower in patients with acute coronary syndromes versus stable coronary artery disease (7.6±3 versus 11.5±6.4 m/s; P=0.02), and this persisted after adjustment for confounders. In contrast, aortic stiffness, assessed by aortic and carotid-femoral PWV, did not differ significantly. CoPWV seems associated with acute coronary events more closely than aortic PWV. High coronary compliance, whether per se or because it leads to a distal shift in compliance mismatch, may expose vulnerable plaques to high cyclic stretch. CoPWV is a new tool to assess local compliance at the coronary level; it paves the way for a new field of research. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  3. An efficient communication scheme for solving Sn equations on message-passing multiprocessors

    International Nuclear Information System (INIS)

    Azmy, Y.Y.

    1993-01-01

    Early models of Intel's hypercube multiprocessors, e.g., the iPSC/1 and iPSC/2, were characterized by the high latency of message passing. This relatively weak dependence of the communication penalty on the size of messages, in contrast to its strong dependence on the number of messages, justified using the Fan-in Fan-out algorithm (which implements a minimum spanning tree path) to perform global operations, such as global sums, etc. Recent models of message-passing computers, such as the iPSC/860 and the Paragon, have been found to possess much smaller latency, thus forcing a reexamination of the issue of performance optimization with respect to communication schemes. Essentially, the Fan-in Fan-out scheme minimizes the number of nonsimultaneous messages sent but not the volume of data traffic across the network. Furthermore, if a global operation is performed in conjunction with the message passing, a large fraction of the attached nodes remains idle as the number of utilized processors is halved in each step of the process. On the other hand, the Recursive Halving scheme offers the smallest communication cost for global operations but has some drawbacks

  4. Noninvasive assessment of coronary stenoses by myocardial imaging during pharmacologic coronary vasodilation. VI. Detection of coronary artery disease in human beings with intravenous N-13 ammonia and positron computed tomography

    International Nuclear Information System (INIS)

    Schelbert, H.R.; Wisenberg, G.; Phelps, M.E.; Gould, K.L.; Henze, E.; Hoffman, E.J.; Gomes, A.; Kuhl, D.E.

    1982-01-01

    The possibility of detecting mild coronary stenoses with positron computed tomography and nitrogen (N-13) ammonia administered during pharmacologic coronary vasodilation was previously demonstrated in chronically instrumented dogs. The feasibility of using this technique in human beings and its sensitivity in determining the degree and extent of coronary artery disease were examined in 13 young normal healthy volunteers and 32 patients with angiographically documented coronary artery disease. N-13 ammonia was administered intravenously and its distribution in the left ventricular myocardium recorded at rest and during dipyridamole-induced coronary hyperemia. In the 13 volunteers, N-13 activity was homogeneous at rest and during hyperemia, whereas 31 of the 32 patients had regional defects on the hyperemic images not present during rest. All six patients with double, all 10 with triple and 15 of 16 patients with single vessel disease (97 percent) were correctly identified with the technique. Two vessel involvement was correctly identified in five of the six patients with double vessel disease and three vessel disease in six of 10 patients. Of all 58 coronary stenoses, 52 (90 percent) were correctly identified. In a subgroup of 11 patients, the technique was compared with exercise thallium-201 planar images, which were abnormal in 10 (91 percent) whereas N-13 images were abnormal in all 11. Of the 19 stenosed coronary arteries in this subgroup, 11 (58 percent) were correctly identified with thallium-201 and 17 (89 percent) with tomography (p less than 0.01). It is concluded that cross-sectional imaging of the myocardial distribution of N-13 ammonia administered during pharmacologic coronary vasodilation is a highly sensitive and accurate means for noninvasive detection of coronary stenoses in human beings and for estimating the extent of coronary artery disease

  5. Multi-pass spectroscopic ellipsometry

    International Nuclear Information System (INIS)

    Stehle, Jean-Louis; Samartzis, Peter C.; Stamataki, Katerina; Piel, Jean-Philippe; Katsoprinakis, George E.; Papadakis, Vassilis; Schimowski, Xavier; Rakitzis, T. Peter; Loppinet, Benoit

    2014-01-01

    Spectroscopic ellipsometry is an established technique, particularly useful for thickness measurements of thin films. It measures polarization rotation after a single reflection of a beam of light on the measured substrate at a given incidence angle. In this paper, we report the development of multi-pass spectroscopic ellipsometry where the light beam reflects multiple times on the sample. We have investigated both theoretically and experimentally the effect of sample reflectivity, number of reflections (passes), angles of incidence and detector dynamic range on ellipsometric observables tanΨ and cosΔ. The multiple pass approach provides increased sensitivity to small changes in Ψ and Δ, opening the way for single measurement determination of optical thickness T, refractive index n and absorption coefficient k of thin films, a significant improvement over the existing techniques. Based on our results, we discuss the strengths, the weaknesses and possible applications of this technique. - Highlights: • We present multi-pass spectroscopic ellipsometry (MPSE), a multi-pass approach to ellipsometry. • Different detectors, samples, angles of incidence and number of passes were tested. • N passes improve polarization ratio sensitivity to the power of N. • N reflections improve phase shift sensitivity by a factor of N. • MPSE can significantly improve thickness measurements in thin films

  6. Treatment strategies in the left main coronary artery disease associated with acute coronary syndromes

    Directory of Open Access Journals (Sweden)

    Ahmet Karabulut

    2015-10-01

    Full Text Available Significant left main coronary artery (LMCA stenosis is not rare and reported 3 to 10% of patients undergoing coronary angiography. Unprotected LMCA intervention is a still clinical challenge and surgery is still going to be a traditional management method in many cardiac centers. With a presentation of drug eluting stent (DES, extensive use of IVUS and skilled operators, number of such interventions increased rapidly which lead to change in recommendation in the guidelines regarding LMCA procedures in the stable angina (Class 2a recommendation for ostial and shaft lesion and class 2b recommendation for distal bifurcation lesion. However, there was not clear consensus about the management of unprotected LMCA lesion associated with acute myocardial infarction (MI with a LMCA culprit lesion itself or distinct culprit lesion of other major coronary arteries. Surgery could be preferred as an obligatory management strategy even in the high risk patients. With this review, we aimed to demonstrate treatment strategies of LMCA disease associated with acute coronary syndrome, particularly acute myocardial infarction (MI. In addition, we presented a short case series with LMCA lesion and ST elevated acute MI in which culprit lesion placed either in the left anterior descending artery or circumflex artery. We reviewed the current medical literature and propose simple algorithm for management.

  7. Role of endothelial function in coronary slow-flow phenomenon with angiographically normal coronaries

    Directory of Open Access Journals (Sweden)

    Srikanth Nathani

    2016-01-01

    Conclusion: Coronary slow flow phenomenon is a marker of atherosclerosis (as documented by carotid intima media thickness and our study has also shown that endothelial function is significantly impaired in patients with coronary slow flow (as documented by impaired endothelial dependent vasodilatation than that of patients with normal epicardial coronaries with normal flow.

  8. Visualization of mcr mRNA in a methanogen by fluorescence in situ hybridization with an oligonucleotide probe and two-pass tyramide signal amplification (two-pass TSA-FISH).

    Science.gov (United States)

    Kubota, Kengo; Ohashi, Akiyoshi; Imachi, Hiroyuki; Harada, Hideki

    2006-09-01

    Two-pass tyramide signal amplification-fluorescence in situ hybridization (two-pass TSA-FISH) with a horseradish peroxidase (HRP)-labeled oligonucleotide probe was applied to detect prokaryotic mRNA. In this study, mRNA of a key enzyme for methanogenesis, methyl coenzyme M reductase (mcr), in Methanococcus vannielii was targeted. Applicability of mRNA-targeted probes to in situ hybridization was verified by Clone-FISH. It was observed that sensitivity of two-pass TSA-FISH was significantly higher than that of TSA-FISH, which was further increased by the addition of dextran sulphate in TSA working solution. Signals from two-pass TSA-FISH were more reliable compared to the weak, spotty signals yielded by TSA-FISH.

  9. Assessment of coronary flow reserve by sestamibi imaging in patients with typical chest pain and normal coronary arteries

    Energy Technology Data Exchange (ETDEWEB)

    Storto, Giovanni; Sorrentino, Anna R.; Pellegrino, Teresa; Liuzzi, Raffaele; Cuocolo, Alberto [University Federico II, Department of Biomorphological and Functional Sciences, Institute of Biostructures and Bioimages of the National Council of Research, Naples (Italy); Petretta, Mario [University Federico II, Department of Internal Medicine, Cardiovascular and Immunological Sciences, Naples (Italy)

    2007-08-15

    We assessed coronary flow reserve (CFR) by sestamibi imaging in patients with typical chest pain, positive exercise stress test and normal coronary vessels. Thirty-five patients with typical chest pain and normal angiogram and 12 control subjects with atypical chest pain underwent dipyridamole/rest {sup 99m}Tc-sestamibi imaging. Myocardial blood flow (MBF) was estimated by measuring first transit counts in the pulmonary artery and myocardial counts from SPECT images. Estimated CFR was expressed as the ratio of stress to rest MBF. Rest MBF and CFR were corrected for rate-pressure product (RPP) and expressed as normalised MBF (MBF{sub n}) and normalised CFR (CFR{sub n}). Coronary vascular resistances (CVR) were calculated as the ratio between mean arterial pressure and estimated MBF. At rest, estimated MBF and MBF{sub n} were lower in controls than in patients (0.98 {+-} 0.4 vs 1.30 {+-} 0.3 counts/pixel/s and 1.14 {+-} 0.5 vs 1.64 {+-} 0.6 counts/pixel/s, respectively, both p < 0.02). Stress MBF was not different between controls and patients (2.34 {+-} 0.8 vs 2.01 {+-} 0.7 counts/pixel/s, p=NS). Estimated CFR was 2.40 {+-} 0.3 in controls and 1.54 {+-} 0.3 in patients (p < 0.0001). After correction for the RPP, CFR{sub n} was still higher in controls than in patients (2.1 {+-} 0.5 vs 1.29 {+-} 0.5, p < 0.0001). At baseline, CVR values were lower (p < 0.01) in patients than in controls. Dipyridamole-induced changes in CVR were greater (p < 0.0001) in controls (-63%) than in patients (-35%). In the overall study population, a significant correlation between dipyridamole-induced changes in CVR and CFR was observed (r = -0.88, p < 0.0001). SPECT might represent a useful non-invasive method for assessing coronary vascular function in patients with angina and a normal coronary angiogram. (orig.)

  10. Fractional Flow Reserve Measurement by Coronary Computed Tomography Angiography: A Review with Future Directions

    Directory of Open Access Journals (Sweden)

    Asim Rizvi

    2016-12-01

    Full Text Available Invasive fractional flow reserve (FFR measurement is currently the gold standard for coronary intervention. FFR measurement by coronary computed tomography angiography (FFRCT is a novel and promising imaging technology that permits noninvasive assessment of physiologically significant coronary lesions. FFRCT is capable of combining the anatomic information provided by coronary computed tomography angiography with computational fluid dynamics to compute FFR. To date, several studies have reported the diagnostic performance of FFRCT compared with invasive FFR measurement as the reference standard. Further studies are now being implemented to determine the clinical feasibility and economic implications of FFRCT techniques. This article provides an overview and discusses the available evidence as well as potential future directions of FFRCT.

  11. Relationship between serum visfatin levels and coronary slow-flow phenomenon.

    Science.gov (United States)

    Cakmak, Huseyin Altug; Aslan, Serkan; Yalcin, Ahmet Arif; Akturk, Ibrahim Faruk; Yalcin, Burce; Uzun, Fatih; Ozturk, Derya; Erturk, Mehmet; Gul, Mehmet

    2015-09-01

    Increased levels of visfatin, a novel adipocytokine, are reported in atherosclerosis, obesity, and type 2 diabetes. The aim of the present study was to investigate the relationship between coronary slow flow (CSF) and visfatin in patients undergoing elective coronary angiography for suspected coronary artery disease. A total of 140 recruited participants (90 patients with CSF and 50 controls) were divided into two groups according to their coronary flow rates. Coronary flow was quantified by thrombolysis in myocardial infarction (TIMI) frame count (TFC). Serum visfatin levels were higher in the CSF group than in the control group (3.29 ± 1.11 vs. 2.70 ± 1.08 ng/ml, p = 0.003). A significant correlation was found between TFC and visfatin (r = 0.535, p < 0.001). The area under the receiver operating characteristic curve was 0.720 (95 % confidence interval, 0.622-0.817, p < 0.001) for visfatin in the diagnosis of CSF. If a cut-off value of 2.59 ng/ml was used, higher levels of visfatin could predict the presence of CSF with 78.9 % sensitivity and 64.0 % specificity. Visfatin levels might be a useful biomarker for predicting CSF in patients undergoing diagnostic coronary angiography.

  12. Prediction of acute coronary syndromes by urinary proteome analysis.

    Directory of Open Access Journals (Sweden)

    Nay M Htun

    Full Text Available Identification of individuals who are at risk of suffering from acute coronary syndromes (ACS may allow to introduce preventative measures. We aimed to identify ACS-related urinary peptides, that combined as a pattern can be used as prognostic biomarker. Proteomic data of 252 individuals enrolled in four prospective studies from Australia, Europe and North America were analyzed. 126 of these had suffered from ACS within a period of up to 5 years post urine sampling (cases. Proteomic analysis of 84 cases and 84 matched controls resulted in the discovery of 75 ACS-related urinary peptides. Combining these to a peptide pattern, we established a prognostic biomarker named Acute Coronary Syndrome Predictor 75 (ACSP75. ACSP75 demonstrated reasonable prognostic discrimination (c-statistic = 0.664, which was similar to Framingham risk scoring (c-statistics = 0.644 in a validation cohort of 42 cases and 42 controls. However, generating by a composite algorithm named Acute Coronary Syndrome Composite Predictor (ACSCP, combining the biomarker pattern ACSP75 with the previously established urinary proteomic biomarker CAD238 characterizing coronary artery disease as the underlying aetiology, and age as a risk factor, further improved discrimination (c-statistic = 0.751 resulting in an added prognostic value over Framingham risk scoring expressed by an integrated discrimination improvement of 0.273 ± 0.048 (P < 0.0001 and net reclassification improvement of 0.405 ± 0.113 (P = 0.0007. In conclusion, we demonstrate that urinary peptide biomarkers have the potential to predict future ACS events in asymptomatic patients. Further large scale studies are warranted to determine the role of urinary biomarkers in clinical practice.

  13. The relationship of plasma decoy receptor 3 and coronary collateral circulation in patients with coronary artery disease.

    Science.gov (United States)

    Yan, Youyou; Song, Dandan; Liu, Lulu; Meng, Xiuping; Qi, Chao; Wang, Junnan

    2017-11-15

    Previously, decoy receptor 3 (DcR3) was found to be a potential angiogenetic factor, while the relationship of DcR3 with coronary collateral circulation formation has not been investigated. In this study, we aimed to investigate whether plasma decoy receptor 3 levels was associated with CCC formation and evaluate its predictive power for CCC status in patients with coronary artery disease. Among patients who underwent coronary angiography with coronary artery disease and had a stenosis of ≥90% were included in our study. Collateral degree was graded according to Rentrope Cohen classification. Patients with grade 2 or 3 collateral degree were enrolled in good CCC group and patients with grade 0 or 1 collateral degree were enrolled in poor CCC group. Plasma DcR3 level was significantly higher in good CCC group (328.00±230.82 vs 194.84±130.63ng/l, p<0.01) and positively correlated with Rentrope grade (p<0.01). In addition, plasma DcR3 was also positively correlated with VEGF-A. Both ROC (receiver operating characteristic curve) and multinomial logistical regression analysis showed that plasma DcR3 displayed potent predictive power for CCC status. Higher plasma DcR3 level was related to better CCC formation and displayed potent predictive power for CCC status. Copyright © 2017. Published by Elsevier Inc.

  14. High coronary calcium score and post-procedural CK-MB are noninvasive predictors of coronary stent restenosis

    Directory of Open Access Journals (Sweden)

    Lee JB

    2017-02-01

    Full Text Available Jae-Beom Lee,1 Yun-Seok Choi,2 Woo-Baek Chung,2 Ami Kwon,2 Chul-Soo Park,2 Man-Young Lee2 1Anyang Sam Hospital, 2Division of Cardiology, Department of Internal Medicine, Youido St Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea Purpose: High coronary calcium score (CCS and post-procedural cardiac enzyme may be related with poor outcomes in patients with coronary stent implantation. Methods: A total of 1,072 patients (63.2% male, mean age: 61.7±10.3 years who underwent coronary multi-detect computed tomography at index procedure and follow-up coronary angiography (CAG after drug-eluting stent (DES were divided into two groups: those with and without target lesion revascularization (TLR; >50% reduction in luminal stent diameter or angina symptoms on follow-up CAG. The CCSs for predicting stent revascularization were elucidated. Results: There were no significant differences between the two groups with regard to risk factors. The initial CCS was significantly higher in the TLR group (1,102.4±743.7 vs 345.8±51.05, P=0.04. After adjustment of significant factors for TLR, only CCS and post-procedural creatine kinase MB form (CK-MB elevation were significant predictors of coronary artery TLR. Receiver operation curve revealed that >800 in CCS had 69% in sensitivity and 88% in specificity about predicting the TLR. Conclusion: High CCS with post-procedural CK-MB might be the useful predictors for TLR after DES implantation. Keywords: coronary restenosis, drug-eluting stents, calcium, creatine kinase

  15. Coronary Revascularization in Children at a Mexican Cardiac Center: Thirteen-Year Outcomes.

    Science.gov (United States)

    Ramírez-Marroquín, Samuel E; Iturriaga-Hernández, Alejandra; Calderón-Colmenero, Juan; Benita-Bordes, Antonio; Cervantes-Salazar, Jorge L

    2017-09-01

    The indications for pediatric coronary revascularization are diverse. There are a large proportion of patients with sequelae of severe inflammatory diseases such as Kawasaki disease, and other less common causes. Retrospective review of ten pediatric patients undergoing coronary artery bypass surgery from January 2004 to December 2016. Ten children and adolescents ranging in age from 2 to 17 (median, 6) years at operation were followed up for as long as 13 years with a median follow-up of 2 years. The surgical indications include ischemia symptoms and/or coronary stenosis angiographically documented. Diagnoses include Kawasaki disease, anomalous origin of the left coronary artery from the pulmonary artery, and iatrogenic lesion of the right coronary artery. All the surgical procedures were performed with cardiopulmonary bypass with crystalloid cardioplegic arrest. The number of distal anastomoses was 1.6 per patient, and the left internal thoracic artery was used in one patient, the right internal thoracic artery in four patients, bilateral internal thoracic artery in four patients, and bilateral internal thoracic artery plus left radial artery in one patient, most frequently for right coronary artery revascularization. The patients underwent noninvasive diagnostic study during follow-up to evaluate their coronary status. The ten patients had no symptoms, and there was no mortality. Although survival was excellent after pediatric coronary bypass in our center, we need to continue the follow-up. Coronary revascularization by means of arterial grafting is a safe and reliable surgical modality for coronary disease in children.

  16. Balloon Occlusion Types in the Treatment of Coronary Perforation during Percutaneous Coronary Intervention

    Directory of Open Access Journals (Sweden)

    Xiangfei Wang

    2014-01-01

    Full Text Available Coronary artery perforation is an uncommon complication in patients with coronary heart disease undergoing percutaneous coronary intervention. However, pericardial tamponade following coronary artery perforation may be lethal, and prompt treatment is crucial in managing such patients. Balloon occlusion and the reversal of anticoagulant activity are the common methods used to prevent cardiac tamponade by reducing the amount of bleeding. Herein, we discuss the pros and cons of currently used occlusion types for coronary perforation. Optimal balloon occlusion methods should reduce the amount of bleeding and ameliorate subsequent myocardial ischemia injury, even during cardiac surgery.

  17. Distal coronary hemoperfusion during percutaneous transluminal coronary angioplasty

    NARCIS (Netherlands)

    Muinck, Ebo Derk de

    1994-01-01

    In this thesis several aspects of passive and active coronary perfusion during coronary angioplasty are investigated. The autoperfusion balloon catheters that were evaluated are the Stack® and the RX-60® catheters (Advanced Cardiovascular Systems, inc., Santa Clara, California, U.S.A). The coronary

  18. The Diagnosis of Spontaneous Coronary Artery Dissection by Optical Coherence Tomography.

    Science.gov (United States)

    Kanda, Takahiro; Tawarahara, Kei; Matsukura, Gaku; Matsunari, Masayoshi; Takabayashi, Rumi; Tamura, Jun; Ozeki, Mariko; Ukigai, Hiroshi

    2018-02-15

    Spontaneous coronary artery dissection (SCAD) is rare, but it frequently presents as acute myocardial infarction. It is frequently fatal and most cases are diagnosed at autopsy. We herein present the case of a 65-year-old woman with ST-elevation and myocardial infarction due to SCAD. Optical coherence tomography (OCT) helped us to confirm the diagnosis. The information on the intravascular morphology provided by OCT imaging is much more detailed in comparison to that provided by coronary angiography (CAG) and intravascular ultrasound (IVUS).

  19. Association of Dyslipidemia and Sex With Coronary Artery Calcium Assessed by Coronary Computed Tomography Angiography.

    Science.gov (United States)

    Asami, Masahiko; Yamaji, Kyohei; Aoki, Jiro; Tanimoto, Shuzou; Watanabe, Mika; Horiuchi, Yu; Furui, Koichi; Kato, Nahoko; Hara, Kazuhiro; Tanabe, Kengo

    2017-10-21

    Previous studies reporting that statin increases coronary artery calcium (CAC) were conducted exclusively on patients with statin as a prevention, regardless of the presence or absence of dyslipidemia. The impact of sex on CAC has not been fully evaluated. We aimed to determine the association of dyslipidemia and sex with CAC using 320-row multi-detector computed tomography (MDCT).Of the 356 consecutive patients who underwent coronary MDCT, 251 patients were enrolled, after excluding those with prior stenting and/or coronary bypass grafting or images showing motion artifacts. The primary outcome measures were the percent calcium volume (PCV) and percent atheroma volume (PAV) per coronary vessel.Multivariable analyses indicated that PCV was significantly higher in dyslipidemia patients without statins than in the subjects without dyslipidemia [partial regression coefficient (PRC): 2.59, 95% confidence interval (CI): 0.83 to 4.34, P = 0.004]. In contrast, PCV was similar in dyslipidemia patients taking statins and those without dyslipidemia (PRC: -1.09, 95% CI: -2.82 to 0.65, P = 0.22). There was no significant difference in PCV between men and women, although women exhibited a significantly lower PAV (PRC: -2.87, 95% CI: -4.54 to -1.20, P = 0.001).In low-risk patients, these results could be translated into hypotheses, which should be tested in future prospective studies. Furthermore, there was no significant difference in CAC between men and women, but women had lower PAV than men.

  20. ACE (I/D polymorphism and response to treatment in coronary artery disease: a comprehensive database and meta-analysis involving study quality evaluation

    Directory of Open Access Journals (Sweden)

    Kitsios Georgios

    2009-06-01

    Full Text Available Abstract Background The role of angiotensin-converting enzyme (ACE gene insertion/deletion (I/D polymorphism in modifying the response to treatment modalities in coronary artery disease is controversial. Methods PubMed was searched and a database of 58 studies with detailed information regarding ACE I/D polymorphism and response to treatment in coronary artery disease was created. Eligible studies were synthesized using meta-analysis methods, including cumulative meta-analysis. Heterogeneity and study quality issues were explored. Results Forty studies involved invasive treatments (coronary angioplasty or coronary artery by-pass grafting and 18 used conservative treatment options (including anti-hypertensive drugs, lipid lowering therapy and cardiac rehabilitation procedures. Clinical outcomes were investigated by 11 studies, while 47 studies focused on surrogate endpoints. The most studied outcome was the restenosis following coronary angioplasty (34 studies. Heterogeneity among studies (p ACE I/D polymorphism on the response to treatment for the rest outcomes (coronary events, endothelial dysfunction, left ventricular remodeling, progression/regression of atherosclerosis, individual studies showed significance; however, results were discrepant and inconsistent. Conclusion In view of available evidence, genetic testing of ACE I/D polymorphism prior to clinical decision making is not currently justified. The relation between ACE genetic variation and response to treatment in CAD remains an unresolved issue. The results of long-term and properly designed prospective studies hold the promise for pharmacogenetically tailored therapy in CAD.

  1. Direct coronary stenting in reducing radiation and radiocontrast consumption

    International Nuclear Information System (INIS)

    Caluk, Jasmin; Osmanovic, Enes; Barakovic, Fahir; Kusljugic, Zumreta; Terzic, Ibrahim; Caluk, Selma; Sofic, Amela

    2010-01-01

    Coronary stenting is the primary means of coronary revascularization. There are two basic techniques of stent implantation: stenting with balloon predilatation of stenosis and stenting without predilatation (direct stenting). Limiting the time that a fluoroscope is activated and by appropriately managing the intensity of the applied radiation, the operator limits radiation in the environment, and this saves the exposure to the patient and all personnel in the room. Nephrotoxicity is one of the most important properties of radiocontrast. The smaller amount of radiocontrast used also provides multiple positive effects, primarily regarding the periprocedural risk for the patients with the reduced renal function. The goal of the study was to compare fluoroscopy time, the amount of radiocontrast, and expenses of material used in direct stenting and in stenting with predilatation. In a prospective study, 70 patients with coronary disease were randomized to direct stenting, or stenting with predilatation. Fluoroscopy time and radiocontrast use were significantly reduced in the directly stented patients in comparison to the patients stented with balloon-predilatation. The study showed a significant reduction of expenses when using a direct stenting method in comparison to stenting with predilatation. If the operator predicts that the procedure can be performed using direct stenting, he is encouraged to do so. Direct stenting is recommended for all percutaneous coronary interventions when appropriate conditions have been met. If direct stenting has been unsuccessful, the procedure can be converted to predilatation

  2. "Which pass is better?" Novel approaches to assess passing effectiveness in elite soccer.

    Science.gov (United States)

    Rein, Robert; Raabe, Dominik; Memmert, Daniel

    2017-10-01

    Passing behaviour is a key property of successful performance in team sports. Previous investigations however have mainly focused on notational measurements like total passing frequencies which provide little information about what actually constitutes successful passing behaviour. Consequently, this has hampered the transfer of research findings into applied settings. Here we present two novel approaches to assess passing effectiveness in elite soccer by evaluating their effects on majority situations and space control in front of the goal. Majority situations are assessed by calculating the number of defenders between the ball carrier and the goal. Control of space is estimated using Voronoi-diagrams based on the player's positions on the pitch. Both methods were applied to position data from 103 German First division games from the 2011/2012, 2012/2013 and 2014/2015 seasons using a big data approach. The results show that both measures are significantly related to successful game play with respect to the number of goals scored and to the probability of winning a game. The results further show that on average passes from the mid-field into the attacking area are most effective. The presented passing efficiency measures thereby offer new opportunities for future applications in soccer and other sports disciplines whilst maintaining practical relevance with respect to tactical training regimes or game performances analysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. A designated centre for people with disabilities operated by St John of God Community Services Ltd, Louth

    LENUS (Irish Health Repository)

    Daly, Caroline

    2013-01-01

    Proper assessment of the physiologic impact of coronary artery stenosis on the LV myocardium can affect patient prognosis and treatment decisions. Cardiac magnetic resonance imaging (CMR) assesses myocardial perfusion by imaging the myocardium during a first-pass transit of an intravenous gadolinium bolus, with spatial and temporal resolution substantially higher than nuclear myocardial perfusion imaging. Coupled with late gadolinium enhancement (LGE) imaging for infarction during the same imaging session, CMR with vasodilating stress perfusion imaging can qualitatively and quantitatively assess the myocardial extent of hypoperfusion from coronary stenosis independent of infarcted myocardium. This approach has been validated experimentally, and multiple clinical trials have established its diagnostic robustness when compared to stress single-photon emission computed tomography. In specialized centers, dobutamine stress CMR has been shown to have incremental diagnostic value above stress echocardiography due to its high imaging quality and ability to image the heart with no restriction of imaging window. This paper reviews the technical aspects, diagnostic utility, prognostic values, challenges to clinical adaptation, and future developments of stress CMR imaging.

  4. Visualization of coronary venous anatomy by cardiovascular magnetic resonance

    Directory of Open Access Journals (Sweden)

    Crean Andrew

    2009-08-01

    Full Text Available Abstract Background Coronary venous imaging with whole-heart cardiovascular magnetic resonance (CMR angiography has recently been described using developmental pulse sequences and intravascular contrast agents. However, the practical utility of coronary venous imaging will be for patients with heart failure in whom cardiac resynchronisation therapy (CRT is being considered. As such complementary information on ventricular function and myocardial viability will be required. The aim of this study was to determine if the coronary venous anatomy could be depicted as part of a comprehensive CMR protocol and using a standard extracellular contrast agent. Methods and Results Thirty-one 3D whole heart CMR studies, performed after intravenous administration of 0.05 mmol/kg gadolinium DTPA, were reviewed. The cardiac venous system was visualized in all patients. The lateral vein of the left ventricle was present in 74%, the anterior interventricular vein in 65%, and the posterior interventricular vein in 74% of patients. The mean maximum distance of demonstrable cardiac vein on the 3D images was 81.5 mm and was dependent on the quality of the 3D data set. Five patients showed evidence of myocardial infarction on late gadolinium enhancement (LGE images. Conclusion Coronary venous anatomy can be reliably demonstrated using a comprehensive CMR protocol and a standard extracellular contrast agent. The combination of coronary venous imaging, assessment of ventricular function and LGE may be useful in the management of patients with LV dysfunction being considered for CRT.

  5. Myocardial scintigraphy using a fatty acid analogue detects coronary artery disease in hemodialysis patients.

    Science.gov (United States)

    Nishimura, Masato; Hashimoto, Tetsuya; Kobayashi, Hiroyuki; Fukuda, Toyofumi; Okino, Koji; Yamamoto, Noriyuki; Fujita, Hiroshi; Inoue Tsunehiko Nishimura, Naoto; Ono, Toshihiko

    2004-08-01

    Coronary artery disease contributes significantly to mortality in end-stage renal disease (ESRD) patients. Single-photon emission computed tomography (SPECT) using an iodinated fatty acid analogue, iodine-123-methyl iodophenylpentadecanoic acid (123I-BMIPP), can assess fatty acid metabolism in the myocardium. We investigated the ability of 123I-BMIPP SPECT to detect coronary artery disease in hemodialysis patients compared with 201thallium chloride (201Tl) SPECT. We prospectively studied 130 ESRD patients undergoing hemodialysis for a mean of 88.6 months (male/female, 77/53; mean age, 63.8 years). Dual SPECT using 123I-BMIPP and 201Tl was performed, followed by coronary angiography. SPECT findings were graded in 17 segments on a five-point scale (0, normal uptake; 4, none) and assessed as a summed score. By coronary angiography, 71.5% of patients (93/130) had significant coronary stenosis (> or =75%), and five patients showed coronary spasm without coronary stenosis. When a BMIPP summed score of 6 or more was defined as abnormal, sensitivity, specificity, and accuracy for detecting coronary artery disease by BMIPP SPECT were 98.0%, 65.6%, and 90.0%, respectively; in contrast, these parameters for detecting coronary artery disease by Tl SPECT were 84.7%, 46.9%, and 75.0%, respectively, when a Tl summed score of 1 or more was defined as abnormal. In receiver operating characteristic analysis, the area under the curve was 0.895 in BMIPP and 0.727 in Tl SPECT, respectively. Resting BMIPP SPECT is superior to Tl SPECT for detecting coronary lesions, and provides safe screening for coronary artery disease among maintenance hemodialysis patients.

  6. Pattern and predictors of dual antiplatelet use after coronary artery bypass graft surgery.

    Science.gov (United States)

    Mori, Makoto; Shioda, Kayoko; Yun, James J; Mangi, Abeel A; Darr, Umer; Geirsson, Arnar

    2018-02-01

    Resumption of dual antiplatelet therapy after coronary artery bypass grafting in patients presenting with acute coronary syndrome is recommended, but the current practice pattern in the United States remains unknown. We aimed to investigate the current pattern of dual antiplatelet therapy use after coronary artery bypass grafting at the Yale-New Haven Hospital. We conducted a single-center retrospective review of patients who presented with acute coronary syndrome and underwent coronary artery bypass grafting between 2014 and 2016. The primary outcome was hospital discharge with dual antiplatelet therapy. Mixed-effect multivariate logistic regression was used to evaluate predictors of dual antiplatelet therapy use or nonuse, accounting for surgeon-specific preference. The discriminatory ability of the model was evaluated with receiver operating characteristics analysis. Of 572 patients included, only 29% were discharged with dual antiplatelet therapy. In the mixed-effect multivariate model isolating surgeon preferences, increase in age (odds ratio, 0.95; 95% confidence interval, 0.92-0.98; P dual antiplatelet therapy use. Off-pump coronary artery bypass grafting compared with on-pump coronary artery bypass grafting was associated with increased odds of dual antiplatelet therapy use (odds ratio, 31.5; 95% confidence interval, 12.8-77.2; P dual antiplatelet therapy use in patients with acute coronary syndrome who underwent coronary artery bypass grafting was low and variable among surgeons. The use or nonuse was guided by previously established risk factors of recurrent ischemia and bleeding, along with surgeon preference. Published by Elsevier Inc.

  7. An angiographic technique for coronary fractional flow reserve measurement: in vivo validation.

    Science.gov (United States)

    Takarada, Shigeho; Zhang, Zhang; Molloi, Sabee

    2013-03-01

    Fractional flow reserve (FFR) is an important prognostic determinant in a clinical setting. However, its measurement currently requires the use of invasive pressure wire, while an angiographic technique based on first-pass distribution analysis and scaling laws can be used to measure FFR using only image data. Eight anesthetized swine were instrumented with flow probe on the proximal segment of the left anterior descending (LAD) coronary arteries. Volumetric blood flow from the flow probe (Qp), coronary pressure (Pa) and right atrium pressure (Pv) were continuously recorded. Flow probe-based FFR (FFRq) was measured from the ratio of flow with and without stenosis. To determine the angiography-based FFR (FFRa), the ratio of blood flow in the presence of a stenosis (QS) to theoretically normal blood flow (QN) was calculated. A region of interest in the LAD arterial bed was drawn to generate time-density curves using angiographic images. QS was measured using a time-density curve and the assumption that blood was momentarily replaced with contrast agent during the injection. QN was estimated from the total coronary arterial volume using scaling laws. Pressure-wire measurements of FFR (FFRp), which was calculated from the ratio of distal coronary pressure (Pd) divided by proximal pressure (Pa), were continuously obtained during the study. A total of 54 measurements of FFRa, FFRp, and FFRq were taken. FFRa showed a good correlation with FFRq (FFRa = 0.97 FFRq +0.06, r(2) = 0.80, p < 0.001), although FFRp overestimated the FFRq (FFRp = 0.657 FFRq + 0.313, r(2) = 0.710, p < 0.0001). Additionally, the Bland-Altman analysis showed a close agreement between FFRa and FFRq. This angiographic technique to measure FFR can potentially be used to evaluate both anatomical and physiological assessments of a coronary stenosis during routine diagnostic cardiac catheterization that requires no pressure wires.

  8. Severity of coronary artery disease in obese patients undergoing coronary angiography

    International Nuclear Information System (INIS)

    Javed, A.; Ali, J.; Kayani, A.M.

    2012-01-01

    Objective: To assess the relationship of severity of coronary artery disease with obesity in patients undergoing coronary angiography. Design: Cross sectional study. Place and Duration of Study: Armed Forces Institute of Cardiology - National Institute of Heart Diseases (AFIC-NIHD), 1st February 2010 to 31st August 2010 Patients and Methods: The study population included 468 patients undergoing coronary angiography. Obesity was classified according to the BMI using the National Institutes of Health (NIH) criteria as normal (BMI 21-24 kg/m2), overweight (BMI 25-29 kg/m2), obesity class I (BMI 30-34 kg/m2), obesity class II (BMI 35 to 39 kg/m2 and obesity class III (BMI 40 or above kg/m2). Coronary angiography data were obtained from the Siemens Queries software system, which maintains the database including detailed angiographic findings of all patients at this institution. Significant lesions were defined as those with >70% diameter narrowing of coronary arteries (>50% for the left main coronary artery). We attempted to quantify the 'severity of CAD' by ascertaining the prevalence of High-Risk Coronary Anatomy (HRCA). Results: Insignificant difference was observed in traditional risk factors i.e. age, diabetes mellitus and smoking except hypertension and gender. Statistically significantly low prevalence of HRCA was encountered in the obese group (57.7%) as compared to normal/overweight group (75.8%) (p < 0.05). Conclusion: We conclude that obesity is associated with less severe coronary artery disease. (author)

  9. [Pregnancy and coronary artery dissection].

    Science.gov (United States)

    Martínez-Quintana, Efrén; Rodríguez-González, Fayna

    2015-01-01

    Acute myocardial infarction during pregnancy is associated with high maternal and fetal mortality. Coronary atherosclerosis is the most common cause due to an increase in the age of the patients and the association with cardiovascular risk factors such as smoking, hypertension, diabetes mellitus, preeclampsia, and the existence of family history of coronary disease. However, thrombosis, coronary dissection or coronary vasospasms are other causes that may justify it. We report the case of a 33 weeks pregnant first-time mother, without cardiovascular risk factors, who presented an acute coronary event in the context of atherosclerotic disease and coronary dissection after percutaneous coronary intervention. Copyright © 2014 Sociedad Española de Arteriosclerosis. Published by Elsevier España. All rights reserved.

  10. Non-invasive assessment of coronary calcification

    International Nuclear Information System (INIS)

    Vliegenthart, Rozemarijn; Oei, Hok-Hay S.; Hofman, Albert; Oudkerk, Matthijs; Witteman, Jackqueline C. M.

    2004-01-01

    Electron-beam tomography (EBT) and multi-detector computed tomography (MDCT) enable the noninvasive assessment of coronary calcification. The amount of coronary calcification, as detected by EBT, has a close relation with the amount of coronary atherosclerosis, which is the substrate for the occurrence of myocardial infarction and sudden cardiac death. Calcification of the coronary arteries can be seen as a cumulative measure of life-time exposure to cardiovascular risk factors. Several studies have shown that the amount of coronary calcification is associated with the risk of coronary heart disease. Therefore, coronary calcification is a promising method for non-invasive detection of asymptomatic subjects at high risk of developing coronary heart disease. Whether measurement of coronary calcification also increases the predictive power of coronary events based on cardiovascular risk factors is topic of current research

  11. Selective coronary scintigraphy

    International Nuclear Information System (INIS)

    Gambini, D.-J.

    1975-01-01

    Isotopic techniques occupy a leading place amongst examinations practicable on coronary patients because of their reliability and the safety and simplicity of their use. The present work reviews the possible applications of selective coronary scintigraphy in pathology. After a brief discussion on scintigraphy, isotopic techniques for myocardium research, coronarography and other methods to study local myocardium perfusion the theoretical bases for the use of the exploration are studied, the techniques and methods employed are reported and the results discussed. Coronary scintigraphy consists of selective injection in the two coronary arteries previously catheterized during a coronarography, of two different populations of microspheres labelled with two physically short-lived indicators: 15μ 99m Tc-labelled serumalbumin microspheres, 10 to 15μ In-labelled siderophiline microspheres. Various studies have shown the complete harmlessness of the exploration when certain precautions are taken regarding the size and number of the spheres. The microspheres disperse into the downstream arterial territory proportionally to the number of capillaries present in the different parts of the irrigated region, and are temporarily stopped in the precapillaries. The preparation of the different images needed to interpret the Face and OAG examination for the left coronary, then for the right coronary, is carried out at the end of the coronarography and lasts about 45 minutes. It is also possible by selective injection in the aorta-coronary bridges to judge their functional condition by observation of the regions they irrigate. 56 patients of the Necker hospital cardiological clinic have been examined [fr

  12. Asymptomatic acute ischemic stroke after primary percutaneous coronary intervention in patients with acute coronary syndrome might be caused mainly by manipulating catheters or devices in the ascending aorta, regardless of the approach to the coronary artery

    International Nuclear Information System (INIS)

    Murai, Motonobu; Hazui, Hiroshi; Sugie, Akira

    2007-01-01

    Asymptomatic acute ischemic stroke (aAIS) following primary percutaneous coronary intervention (p-PCI) in patients with acute coronary syndrome (ACS) has not been studied in detail. Of 75 patients who underwent p-PCI, 26 (34.7%) developed aAIS as determined by diffusion-weighted magnetic resonance imaging (MRI). Including the approach to the coronary artery (via lower limb or right upper limb), 23 factors were compared between patients with (n=26) and without (n=49) aAIS. Age, hypertension, smoking, plasma glucose levels, Killip grade, right coronary artery (RCA) as culprit vessel, percutaneous coronary intervention (PCI) time, and the frequency of device insertion into the coronary artery differed in a statistically significant manner. However, multivariate analysis showed that the RCA (odds ratio 3.477) and the frequency of device insertion (1.375) were independent factors linked to the incidence of aAIS. Moreover, anterior or posterior location and left or right cerebral circulation of aAIS were equivalent in both approaches. Cranial MRI images following emergency PCI revealed that 34.7% of the patients with ACS had aAIS that might be caused by manipulating the catheter or devices in the ascending aorta, micro-air bubble embolism during injection, or micro-thrombus embolism derived from the ACS lesions during the PCI procedure. (author)

  13. Coronary artery calcification identified by CT in patients over forty years of age

    International Nuclear Information System (INIS)

    Woodring, J.H.; West, J.W.

    1989-01-01

    In a study of 100 unselected patients forty years of age or older, routine CT of the thorax demonstrated coronary artery calcification in 41%. Calcification of the left anterior descending was most common, occurring in 34%. For patients, sixty years of age and over, clinical evidence of coronary artery disease was 1.7 times more common in those with calcification compared to those without; however, for patients under 60, coronary artery disease was 5.5 times more common in those with calcification than those without. Because of the strong relationship which is known to exist between coronary artery calcification and coronary arteriosclerosis, we believe that the incidental discovery of coronary artery calcification on routine CT of the thorax has significance. All patients under 60 with coronary artery calcification discovered on CT should be investigated for hyperlipidemia if this has not been done, and, if they are not known to have a history of coronary artery disease, they should have a stress test and, if positive, arteriography may be warranted. 30 refs., 5 figs

  14. [Experimental evaluation of the role of the coronary sinus pressure in the regulation of coronary return volume via the coronary sinus. Surgical considerations in atrio-pulmonary diversion procedures].

    Science.gov (United States)

    Fantidis, P; Fernández Ruiz, M A; Madero Jarabo, R; Moreno Granados, F; Cordovilla Zurdo, G; Sanz Galeote, E

    1990-11-01

    In order to find out the validity of the vascular waterfall mechanism in coronary venous circulation, the role of coronary sinus pressure in the regulation of coronary return volume via the coronary sinus is studied in healthy animals. An experimental model of pressure regulation in the coronary sinus was prepared, and aortic pressure, EKG and the cardiac output (measured by thermodilution) were recorded. The return volume via the coronary sinus was measured at coronary sinus pressure of 10 or less, 15, 20, and 25 mmHg or more, for a total of 36 determinations. Increased coronary sinus pressure did not produce significant changes in aortic pressure, heart rate, cardiac index or coronary return volume via coronary sinus. When coronary sinus pressure was 25 mmHg or more, there was a significant decline in the average of coronary return volume via coronary sinus. Nevertheless, stepwise variant regression showed that the coronary sinus pressure per se does not condition the volume of coronary return via the coronary sinus. Our results suggest that in the healthy animals, the vascular waterfall mechanism in coronary venous circulation is not valid. Our results suggest that in the correction of congenital cardiac malformations using atriopulmonary anastomosis procedures, employing techniques that ensure coronary sinus drainage into the left atrium, in order to avoid the hemodynamic repercussions attributable to the vascular waterfall mechanism, is not justified.

  15. Reducing Radiation Dose in Coronary Angiography and Angioplasty Using Image Noise Reduction Technology.

    Science.gov (United States)

    Kastrati, Mirlind; Langenbrink, Lukas; Piatkowski, Michal; Michaelsen, Jochen; Reimann, Doris; Hoffmann, Rainer

    2016-08-01

    This study sought to quantitatively evaluate the reduction of radiation dose in coronary angiography and angioplasty with the use of image noise reduction technology in a routine clinical setting. Radiation dose data from consecutive 605 coronary procedures (397 consecutive coronary angiograms and 208 consecutive coronary interventions) performed from October 2014 to April 2015 on a coronary angiography system with noise reduction technology (Allura Clarity IQ) were collected. For comparison, radiation dose data from consecutive 695 coronary procedures (435 coronary angiograms and 260 coronary interventions) performed on a conventional coronary angiography system from October 2013 to April 2014 were evaluated. Patient radiation dosage was evaluated based on the cumulative dose area product. Operators and operator practice did not change between the 2 evaluated periods. Patient characteristics were collected to evaluate similarity of patient groups. Image quality was evaluated on a 5-grade scale in 30 patients of each group. There were no significant differences between the 2 evaluated groups in gender, age, weight, and fluoroscopy time (6.8 ± 6.1 vs 6.9 ± 6.3 minutes, not significant). The dose area product was reduced from 3195 ± 2359 to 983 ± 972 cGycm(2) (65%, p technology. Image quality was graded as similar between the evaluated systems (4.0 ± 0.7 vs 4.2 ± 0.6, not significant). In conclusion, a new x-ray technology with image noise reduction algorithm provides a substantial reduction in radiation exposure without the need to prolong the procedure or fluoroscopy time. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Role of coronary physiology in the contemporary management of coronary artery disease

    Science.gov (United States)

    Ruparelia, Neil; Kharbanda, Rajesh K

    2015-01-01

    Coronary artery disease (CAD) remains the leading cause of death worldwide with approximately 1 in 30 patients with stable CAD experiencing death or acute myocardial infarction each year. The presence and extent of resultant myocardial ischaemia has been shown to confer an increased risk of adverse outcomes. Whilst, optimal medical therapy (OMT) forms the cornerstone of the management of patients with stable CAD, a significant number of patients present with ischaemia refractory to OMT. Historically coronary angiography alone has been used to determine coronary lesion severity in both stable and acute settings. It is increasingly clear that this approach fails to accurately identify the haemodynamic significance of lesions; especially those that are visually “intermediate” in severity. Revascularisation based upon angiographic appearances alone may not reduce coronary events above OMT. Technological advances have enabled the measurement of physiological indices including the fractional flow reserve, the index of microcirculatory resistance and the coronary flow reserve. The integration of these parameters into the routine management of patients presenting to the cardiac catheterization laboratory with CAD represents a critical adjunctive tool in the optimal management of these patients by identifying patients that would most benefit from revascularisation and importantly also highlighting patients that would not gain benefit and therefore reducing the likelihood of adverse outcomes associated with coronary revascularisation. Furthermore, these techniques are applicable to a broad range of patients including those with left main stem disease, proximal coronary disease, diabetes mellitus, previous percutaneous coronary intervention and with previous coronary artery bypass grafting. This review will discuss current concepts relevant to coronary physiology assessment, its role in the management of both stable and acute patients and future applications. PMID

  17. Role of coronary physiology in the contemporary management of coronary artery disease.

    Science.gov (United States)

    Ruparelia, Neil; Kharbanda, Rajesh K

    2015-02-16

    Coronary artery disease (CAD) remains the leading cause of death worldwide with approximately 1 in 30 patients with stable CAD experiencing death or acute myocardial infarction each year. The presence and extent of resultant myocardial ischaemia has been shown to confer an increased risk of adverse outcomes. Whilst, optimal medical therapy (OMT) forms the cornerstone of the management of patients with stable CAD, a significant number of patients present with ischaemia refractory to OMT. Historically coronary angiography alone has been used to determine coronary lesion severity in both stable and acute settings. It is increasingly clear that this approach fails to accurately identify the haemodynamic significance of lesions; especially those that are visually "intermediate" in severity. Revascularisation based upon angiographic appearances alone may not reduce coronary events above OMT. Technological advances have enabled the measurement of physiological indices including the fractional flow reserve, the index of microcirculatory resistance and the coronary flow reserve. The integration of these parameters into the routine management of patients presenting to the cardiac catheterization laboratory with CAD represents a critical adjunctive tool in the optimal management of these patients by identifying patients that would most benefit from revascularisation and importantly also highlighting patients that would not gain benefit and therefore reducing the likelihood of adverse outcomes associated with coronary revascularisation. Furthermore, these techniques are applicable to a broad range of patients including those with left main stem disease, proximal coronary disease, diabetes mellitus, previous percutaneous coronary intervention and with previous coronary artery bypass grafting. This review will discuss current concepts relevant to coronary physiology assessment, its role in the management of both stable and acute patients and future applications.

  18. Comparison of cryogenic low-pass filters

    Science.gov (United States)

    Thalmann, M.; Pernau, H.-F.; Strunk, C.; Scheer, E.; Pietsch, T.

    2017-11-01

    Low-temperature electronic transport measurements with high energy resolution require both effective low-pass filtering of high-frequency input noise and an optimized thermalization of the electronic system of the experiment. In recent years, elaborate filter designs have been developed for cryogenic low-level measurements, driven by the growing interest in fundamental quantum-physical phenomena at energy scales corresponding to temperatures in the few millikelvin regime. However, a single filter concept is often insufficient to thermalize the electronic system to the cryogenic bath and eliminate spurious high frequency noise. Moreover, the available concepts often provide inadequate filtering to operate at temperatures below 10 mK, which are routinely available now in dilution cryogenic systems. Herein we provide a comprehensive analysis of commonly used filter types, introduce a novel compact filter type based on ferrite compounds optimized for the frequency range above 20 GHz, and develop an improved filtering scheme providing adaptable broad-band low-pass characteristic for cryogenic low-level and quantum measurement applications at temperatures down to few millikelvin.

  19. Comparison of cryogenic low-pass filters.

    Science.gov (United States)

    Thalmann, M; Pernau, H-F; Strunk, C; Scheer, E; Pietsch, T

    2017-11-01

    Low-temperature electronic transport measurements with high energy resolution require both effective low-pass filtering of high-frequency input noise and an optimized thermalization of the electronic system of the experiment. In recent years, elaborate filter designs have been developed for cryogenic low-level measurements, driven by the growing interest in fundamental quantum-physical phenomena at energy scales corresponding to temperatures in the few millikelvin regime. However, a single filter concept is often insufficient to thermalize the electronic system to the cryogenic bath and eliminate spurious high frequency noise. Moreover, the available concepts often provide inadequate filtering to operate at temperatures below 10 mK, which are routinely available now in dilution cryogenic systems. Herein we provide a comprehensive analysis of commonly used filter types, introduce a novel compact filter type based on ferrite compounds optimized for the frequency range above 20 GHz, and develop an improved filtering scheme providing adaptable broad-band low-pass characteristic for cryogenic low-level and quantum measurement applications at temperatures down to few millikelvin.

  20. PLACENTAL GROWTH FACTOR AND CORONARY NEOANGIOGENESIS IN CORONARY HEART DISEASE

    Directory of Open Access Journals (Sweden)

    M. V. Tulikov

    2013-01-01

    Full Text Available Neoangiogenesis in coronary heart disease is a protective reaction aimed to improve ischemic myocardial perfusion, by increasing the number and size of arterial collaterals. Placental growth factor (PlGF is one of the key peptides regulating angiogenic processes in atherosclerosis. In particular, a number of investigators have shown that injection of recombinant PlGF into the system or regional blood flow can stimulate neoangiogenesis. On the other hand, there is evidence confirming the involvement of PlGF in the progression of atherosclerosis and in the development of acute coronary syndrome. In this connection, the problem of investigating the efficiency and safety of possible use of PlGF preparations, as well as its place in the diagnosis of coronary heart disease and acute coronary syndrome remains urgent

  1. Effect of tamoxifen on the coronary vascular reactivity of spontaneously hypertensive female rats

    Directory of Open Access Journals (Sweden)

    M.V. Borgo

    2011-08-01

    Full Text Available Tamoxifen has been associated with a reduction in the incidence of myocardial infarction. However, the effects of tamoxifen on coronary reactivity have not been fully elucidated. The objective of this study was to determine the effects of chronic treatment with tamoxifen on coronary vascular reactivity in spontaneously hypertensive rats (SHR. Female SHR were divided into four groups (N = 7 each: sham-operated (SHAM, sham-operated and treated with tamoxifen (10 mg/kg by gavage for 90 days (TAMOX, ovariectomized (OVX, and ovariectomized and treated with tamoxifen (OVX+TAMOX. Mean arterial pressure (MAP, heart rate (HR, coronary perfusion pressure (CPP, and coronary vascular reactivity were measured. MAP and HR were reduced (9.42 and 11.67%, respectively in the OVX+TAMOX group compared to the OVX group (P < 0.01. The coronary vascular reactivity of the OVX+TAMOX group presented smaller vasoconstrictor responses to acetylcholine (2-64 µg when compared to the OVX group (P < 0.01 and this response was similar to that of the SHAM group. The adenosine-induced vasodilator response was greater in the TAMOX group compared to the SHAM and OVX groups (P < 0.05. Baseline CPP was higher in OVX+TAMOX and TAMOX groups (136 ± 3.6 and 130 ± 1.5 mmHg than in OVX and SHAM groups (96 ± 2 and 119 ± 2.3 mmHg; P < 0.01. Tamoxifen, when combined with OVX, attenuated the vasoconstriction induced by acetylcholine and increased the adenosine-induced vasodilatory response, as well as reducing the MAP, suggesting beneficial effects of tamoxifen therapy on coronary vascular reactivity after menopause.

  2. Model of the coronary circulation based on pressure dependence of coronary resistance and compliance

    NARCIS (Netherlands)

    Bruinsma, P.; Arts, T.; Dankelman, J.; Spaan, J. A.

    1988-01-01

    The effect of pressure-dependent changes in vascular volume, resistance and capacitance in the coronary micro-circulation, has been studied by a distributed mathematical model of the coronary micro-vasculature in the left ventricular wall. The model does not include regulation of coronary blood flow

  3. Coronary artery calcification in Kawasaki disease

    International Nuclear Information System (INIS)

    Ino, T.; Shimazaki, S.; Akimoto, K.; Park, I.; Nishimoto, K.; Yabuta, K.; Tanaka, A.

    1990-01-01

    To evaluate the angiographic features of coronary lesions in Kawasaki disease with coronary artery calcification, cinefluoroscopy and cineangiography were retrospectively reviewed in 116 patients who had undergone coronary angiography between 1982 and 1989. Angiographic abnormalities of coronary arteries were demonstrated in 55 of 116 patients. In 5 (9.1%) of the 55 patients, 9 with calcification were identified by cinefluoroscopy and chest X-ray. Eight of the 9 calcified lesions showed a circular or ring-shape configuration. Coronary angiography revealed a total occlusion of the right coronary artery with collateral circulation from the distal left coronary artery in 2 patients and a severe stenosis of the right coronary artery in 2 patients, in whom anticoagulant therapy had not been continued during the follow-up periods. The remaining patient in whom anticoagulant therapy had been continued had bilateral aneurysms but no significant stenosis. These results indicate that a ring-shape calcification on chest X-ray in 2 patients with a history of Kawasaki disease may suggest an involvement by coronary artery stenosis even when anticoagulant drugs had been given. Therefore, coronary angiography should be performed to evaluate the stenotic lesions if this type of calcification is found by routine radiographic examination. (orig.)

  4. Noninvasive Coronary Angiography with 64-Channel Multidetector Computed Tomography in Patients with Acute Coronary Syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Ulimoen, G. R.; Gjoennaess, E.; Atar, D.; Dahl, T.; Stranden, E.; Sandbaek, G. (Dept. of Radiology, Dept. of Vascular Diagnosis and Research, and Division of Cardiology, Aker Univ. Hospital, Oslo (Norway))

    2008-12-15

    Background: Advances in computer tomography (CT) imaging technology in recent years have facilitated the possibility of noninvasive coronary angiography. Purpose: To compare the diagnostic accuracy of 64-channel multidetector computed tomography (MDCT) with conventional invasive coronary angiography (ICA) for the detection of significant coronary stenosis in patients with acute coronary syndrome (ACS). Material and Methods: MDCT was performed in 60 patients classified with non-ST-elevation infarction (NSTEMI) or unstable angina and scheduled for ICA within 3 days. The diagnostic accuracy of MDCT was evaluated using quantitative coronary angiography (QCA) as the gold standard. Results: 48 out of 60 patients had interpretable scans by both MDCT and ICA. On a segment-based analysis, 488 out of 665 segments with a diameter of =1.5 mm, as defined by QCA, were interpretable by MDCT. Sensitivity was 78%, specificity 87%, positive predictive value 47%, and negative predictive value 97% in detecting and excluding significant coronary stenosis, as defined with MDCT. On a per patient-based analysis, sensitivity was 89%, specificity 50%, positive predictive value 84%, and negative predictive value 60%. Conclusion: Limited diagnostic accuracy restricts the usefulness of coronary MDCT in patient groups with a high pretest probability of disease, such as in acute coronary syndrome.

  5. Noninvasive Coronary Angiography with 64-Channel Multidetector Computed Tomography in Patients with Acute Coronary Syndrome

    International Nuclear Information System (INIS)

    Ulimoen, G. R.; Gjoennaess, E.; Atar, D.; Dahl, T.; Stranden, E.; Sandbaek, G.

    2008-01-01

    Background: Advances in computer tomography (CT) imaging technology in recent years have facilitated the possibility of noninvasive coronary angiography. Purpose: To compare the diagnostic accuracy of 64-channel multidetector computed tomography (MDCT) with conventional invasive coronary angiography (ICA) for the detection of significant coronary stenosis in patients with acute coronary syndrome (ACS). Material and Methods: MDCT was performed in 60 patients classified with non-ST-elevation infarction (NSTEMI) or unstable angina and scheduled for ICA within 3 days. The diagnostic accuracy of MDCT was evaluated using quantitative coronary angiography (QCA) as the gold standard. Results: 48 out of 60 patients had interpretable scans by both MDCT and ICA. On a segment-based analysis, 488 out of 665 segments with a diameter of =1.5 mm, as defined by QCA, were interpretable by MDCT. Sensitivity was 78%, specificity 87%, positive predictive value 47%, and negative predictive value 97% in detecting and excluding significant coronary stenosis, as defined with MDCT. On a per patient-based analysis, sensitivity was 89%, specificity 50%, positive predictive value 84%, and negative predictive value 60%. Conclusion: Limited diagnostic accuracy restricts the usefulness of coronary MDCT in patient groups with a high pretest probability of disease, such as in acute coronary syndrome

  6. Automated processing of first-pass radionuclide angiocardiography by factor analysis of dynamic structures

    Energy Technology Data Exchange (ETDEWEB)

    Cavailloles, F.; Valette, H.; Hebert, J.-L.; Bazin, J.-P.; Di Paola, R.; Capderou, A.

    1987-05-01

    A method for automatic processing of cardiac first-pass radionuclide study is presented. This technique, factor analysis of dynamic structures (FADS) provides an automatic separation of anatomical structures according to their different temporal behaviour, even if they are superimposed. FADS has been applied to 76 studies. A description of factor patterns obtained in various pathological categories is presented. FADS provides easy diagnosis of shunts and tricuspid insufficiency. Quantitative information derived from the factors (cardiac output and mean transit time) were compared to those obtained by the region of interest method. Using FADS, a higher correlation with cardiac catheterization was found for cardiac output calculation. Thus compared to the ROI method, FADS presents obvious advantages: a good separation of overlapping cardiac chambers is obtained; this operator independent method provides more objective and reproducible results.

  7. Automated processing of first-pass radionuclide angiocardiography by factor analysis of dynamic structures

    International Nuclear Information System (INIS)

    Cavailloles, F.; Valette, H.; Hebert, J.-L.; Bazin, J.-P.; Di Paola, R.; Capderou, A.

    1987-01-01

    A method for automatic processing of cardiac first-pass radionuclide study is presented. This technique, factor analysis of dynamic structures (FADS) provides an automatic separation of anatomical structures according to their different temporal behaviour, even if they are superimposed. FADS has been applied to 76 studies. A description of factor patterns obtained in various pathological categories is presented. FADS provides easy diagnosis of shunts and tricuspid insufficiency. Quantitative information derived from the factors (cardiac output and mean transit time) were compared to those obtained by the region of interest method. Using FADS, a higher correlation with cardiac catheterization was found for cardiac output calculation. Thus compared to the ROI method, FADS presents obvious advantages: a good separation of overlapping cardiac chambers is obtained; this operator independent method provides more objective and reproducible results. (author)

  8. Spontaneous coronary artery dissection associated with apical hypertrophic cardiomyopathy

    International Nuclear Information System (INIS)

    Tuncer, M.; Gumrukcuoglu, H.A.; Ekim, H.; Gunes, Y.; Simsek, H.

    2010-01-01

    Apical hypertrophic cardiomyopathy (HCM) is a relatively uncommon inherited disease. Spontaneous coronary artery dissection (SCAD) is also uncommonly observed, which often occurs in pregnant or post partum women but is rare in men. This report describes a 38 years old man with apical hypertrophic cardiomyopathy who developed SCAD leading to acute inferior myocardial infarction. After emergent appendectomy operation at another hospital, he was immediately transferred to the Cardiology Department of our hospital due to acute myocardial infarction. He emergently underwent coronary angiography which showed a long dissection involving the right coronary. He underwent an emergent CABG with cardiopulmonary bypass. Postoperative recovery was uneventful and he was discharged. According to our knowledge, no case of spontaneous coronary artery dissection associated with apical hypertrophic cardiomyopathy unrelated to postpartum period or oral contraceptive use has been reported so far. (author)

  9. Multiple giant coronary aneurysms arising from coronary istula to the pulmonary artery revealed in aorta CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Eun Ju; Lee, Ki Nam [Dept. of Radiology, Dong A University Hospital, Dong-A University College of Medicine, Busan (Korea, Republic of); Lee, Jong Min [Dept. of Radiology, Kyungpook National University Hospital, Kyungpook National University College of Medicine, Daegu (Korea, Republic of)

    2015-12-15

    Coronary fistula is a rare coronary abnormality through which blood drains into the cardiac chamber, great vessel or other vessels. In addition, giant aneurysm arising from coronary fistula is rare pathologic manifestation. Herein, we presented a rare case of multiple giant coronary artery aneurysms arising from coronary to pulmonary artery fistula in a 79-year-old woman presenting with sudden loss of consciousness. The aneurysms were detected using thoracic computed tomography angiography and consequently confirmed by invasive coronary angiography.

  10. Predicting late restenosis after coronary angioplasty by very early (12 to 24 h) thallium-201 scintigraphy: Implications with regard to mechanisms of late coronary restenosis

    International Nuclear Information System (INIS)

    Hardoff, R.; Shefer, A.; Gips, S.; Merdler, A.; Flugelman, M.Y.; Halon, D.A.; Lewis, B.S.

    1990-01-01

    To examine whether late coronary restenosis may be predicted by abnormalities of myocardial perfusion in the early hours after successful percutaneous transluminal coronary angioplasty and to study in greater detail the mechanisms involved in the development of late coronary restenosis after angioplasty, a prospective study was undertaken in 90 consecutive patients. Thallium-201 scintigrams were recorded at rest and during the stress of atrial pacing, 12 to 24 h after angioplasty, and the results were related to the findings at angiography in 70 patients undergoing late cardiac catheterization. A reversible thallium-201 perfusion defect was found in 39 (38%) of 104 myocardial regions supplied by the dilated coronary vessel and identified a subset of patients at high risk of late (6 to 12 months) angiographic restenosis (sensitivity 77%, specificity 67%). In contrast, late coronary restenosis developed in only 7 (11%) of 65 vessels and in 5 (14%) of 37 patients with a nonischemic thallium-201 scintigram on day 1 (p less than 0.005). Multivariate logistic regression analysis of 14 possible preangioplasty and periangioplasty clinical and angiographic variables selected reversible perfusion defect on the thallium-201 scintigram on day 1 (p = 0.016) and immediate postangioplasty residual coronary narrowing (p = 0.004) as significant independent predictors of late restenosis, with younger patient age as an additional less powerful predictor (p less than 0.05). The findings have important implications regarding the pathogenesis of late coronary restenosis in patients undergoing successful angioplasty and they imply that in the majority of these patients pathophysiologic events in the early minutes and hours after angioplasty may determine the development of late restenosis

  11. Large coronary intramural hematomas

    DEFF Research Database (Denmark)

    Antonsen, Lisbeth; Thayssen, Per; Jensen, Lisette Okkels

    2015-01-01

    Isolated spontaneous coronary intramural hematoma is a unique subset of spontaneous coronary artery dissection that is characterized by a hemorrhage limited to the medial-adventitial layers, causing subsequent hematoma formation without visible intimal flaps. It is an infrequent and serious...... diagnostics and treatment strategy. Coronary intramural hematomas can also occur iatrogenically, as a complication to percutaneous coronary intervention (PCI). Coronary angiography (CAG) has limited diagnostic value in the absence of intimal dissections, and lesions are often angiographically ambiguous....... Intravascular ultrasound (IVUS) is an important diagnostic tool in establishing the correct diagnosis, as it provides a complete vessel wall assessment, and enables morphometric information regarding the magnitude and severity of the underlying hematoma. Due to the rarity of this clinical scenario...

  12. Intraoperative echocardiographic imaging of coronary arteries and graft anastomoses during coronary artery bypass grafting without cardiopulmonary bypass.

    Science.gov (United States)

    Suematsu, Y; Takamoto, S; Ohtsuka, T

    2001-12-01

    No accepted approach exists for the intraoperative evaluation of the quality of coronary arteries and the technical adequacy of graft anastomoses during coronary artery bypass grafting without cardiopulmonary bypass. We assessed the accuracy of high-frequency epicardial echocardiography and power Doppler imaging in evaluating coronary arteries during coronary artery bypass grafting without cardiopulmonary bypass. To validate measurements of coronary arteries and graft anastomoses by high-frequency epicardial echocardiography and power Doppler imaging, we compared luminal diameters determined by these methods with diameters determined histologically in a study of off-pump coronary artery bypass grafting in 20 dogs. Technical errors were deliberately created in 10 grafts (stenosis group). The results of these animal validation studies showed that the maximum luminal diameters of coronary arteries and graft anastomoses measured by high-frequency epicardial echocardiography (HEE) and power Doppler imaging (PDI) correlated well with the histologic measurements: HEE = 1.027 x Histologic measurements + 0.005 (P anastomoses were examined intraoperatively by high-frequency epicardial echocardiography and power Doppler imaging, and luminal diameters determined by power Doppler imaging were compared with those determined by postoperative coronary angiography. The results demonstrated that graft anastomosis by power Doppler imaging correlated well with the angiographic measurements: PDI = 1.018 x Angiographic measurements - 0.106 (P anastomoses and can detect technical errors and inadequacies during coronary artery bypass grafting without cardiopulmonary bypass.

  13. By-pass flows and temperature distribution in a hot gas duct internally insulated by carbon stone

    International Nuclear Information System (INIS)

    Konuk, A.A.

    1979-01-01

    A mathematical model has been developed to calculate by-pass flows and temperature distribution in a hot gas duct internally insulated by carbon stone rings. The equations of conservation of mass and momentum are solved for a piping system to obtain axial and radial by-pass velocities. The energy equation is solved next by a marching method to obtain the radial temperature distribution along the duct. The results, although qualitative due to simplifications in the model, are useful to study the effects of duct geometry on its performance. (Author) [pt

  14. Regression of coronary atherosclerosis by simvastatin

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per; Pedersen, Knud Erik

    2004-01-01

    BACKGROUND: Angiography of the coronary arteries reflects only changes in luminal dimensions. With intravascular ultrasound, cross-sectional images can be obtained and area measurements can be added to calculate volumes of the external elastic membrane (EEM), plaque plus media (P+M), and lumen. T...

  15. Motivation is a crucial factor for adherence to a healthy lifestyle among people with coronary heart disease after percutaneous coronary intervention.

    Science.gov (United States)

    Kähkönen, Outi; Kankkunen, Päivi; Saaranen, Terhi; Miettinen, Heikki; Kyngäs, Helvi; Lamidi, Marja-Leena

    2015-10-01

    To test the Theory of Adherence of People with Chronic Disease with regard to adherence to treatment among patients with coronary heart disease after a percutaneous coronary intervention. Increased knowledge of the concept of adherence is needed for the development of nursing interventions and nursing guidelines for patients with coronary heart disease. A cross-sectional, multi-centre study. This study was conducted from February-December 2013 with 416 patients with coronary heart disease 4 months after undergoing a percutaneous coronary intervention. A self-reported questionnaire was used to assess their adherence to treatment. Data were analysed using structural equation modelling. The theory explained 45% of the adherence to a healthy lifestyle and 7% of the adherence to medication. Structural equation modelling confirmed that motivation and results of care had the highest association with adherence to a healthy lifestyle. Responsibility was associated with adherence to medication. Support from next of kin, support from nurses and physicians, and motivation, co-operation, fear of complications and a sense of normality were associated with adherence. Patients who are motivated to perform self-care and consider the results of care to be important were more likely to adhere to a healthy lifestyle. Responsible patients were more likely to adhere to their medication. It is important to account for these elements as a part of secondary prevention strategies among patients with coronary heart disease after a percutaneous coronary intervention. © 2015 John Wiley & Sons Ltd.

  16. A Case of Cardiac Cephalalgia Showing Reversible Coronary Vasospasm on Coronary Angiogram

    Science.gov (United States)

    Yang, YoungSoon; Jin, Dong Gyu; Jang, Il Mi; Jang, YoungHee; Na, Hae Ri; Kim, SanYun

    2010-01-01

    Background Under certain conditions, exertional headaches may reflect coronary ischemia. Case Report A 44-year-old woman developed intermittent exercise-induced headaches with chest tightness over a period of 10 months. Cardiac catheterization followed by acetylcholine provocation demonstrated a right coronary artery spasm with chest tightness, headache, and ischemic effect of continuous electrocardiography changes. The patient's headache disappeared following intra-arterial nitroglycerine injection. Conclusions A coronary angiogram with provocation study revealed variant angina and cardiac cephalalgia, as per the International Classification of Headache Disorders (code 10.6). We report herein a patient with cardiac cephalalgia that manifested as reversible coronary vasospasm following an acetylcholine provocation test. PMID:20607049

  17. Ultrastructural evaluation of multiple pass low energy versus single pass high energy radio-frequency treatment.

    Science.gov (United States)

    Kist, David; Burns, A Jay; Sanner, Roth; Counters, Jeff; Zelickson, Brian

    2006-02-01

    The radio-frequency (RF) device is a system capable of volumetric heating of the mid to deep dermis and selective heating of the fibrous septa strands and fascia layer. Clinically, these effects promote dermal collagen production, and tightening of these deep subcutaneous structures. A new technique of using multiple low energy passes has been described which results in lower patient discomfort and fewer side effects. This technique has also been anecdotally described as giving more reproducible and reliable clinical results of tissue tightening and contouring. This study will compare ultrastructural changes in collagen between a single pass high energy versus up to five passes of a multiple pass lower energy treatment. Three subjects were consented and treated in the preauricular region with the RF device using single or multiple passes (three or five) in the same 1.5 cm(2) treatment area with a slight delay between passes to allow tissue cooling. Biopsies from each treatment region and a control biopsy were taken immediately, 24 hours or 6 months post treatment for electron microscopic examination of the 0-1 mm and 1-2 mm levels. Sections of tissue 1 mm x 1 mm x 80 nm were examined with an RCA EMU-4 Transmission Electron Microscope. Twenty sections from 6 blocks from each 1 mm depth were examined by 2 blinded observers. The morphology and degree of collagen change in relation to area examined was compared to the control tissue, and estimated using a quantitative scale. Ultrastructural examination of tissue showed that an increased amount of collagen fibril changes with increasing passes at energies of 97 J (three passes) and 122 J (five passes), respectively. The changes seen after five multiple passes were similar to those detected after much more painful single pass high-energy treatments. This ultrastructural study shows changes in collagen fibril morphology with an increased effect demonstrated at greater depths of the skin with multiple low-fluence passes

  18. Vasomotor Regulation of Coronary Microcirculation by Oxidative Stress: Role of Arginase

    Directory of Open Access Journals (Sweden)

    Lih eKuo

    2013-08-01

    Full Text Available Overproduction of reactive oxygen species, i.e., oxidative stress, is associated with the activation of redox signaling pathways linking to inflammatory insults and cardiovascular diseases by impairing endothelial function and consequently blood flow dysregulation due to microvascular dysfunction. This review focuses on the regulation of vasomotor function in the coronary microcirculation by endothelial nitric oxide (NO during oxidative stress and inflammation related to the activation of L-arginine consuming enzyme arginase. Superoxide produced in the vascular wall compromises vasomotor function by not only scavenging endothelium-derived NO but also inhibiting prostacyclin synthesis due to formation of peroxynitrite. The upregulation of arginase contributes to the deficiency of endothelial NO and microvascular dysfunction in various vascular diseases by initiating or following oxidative stress and inflammation. Hydrogen peroxide, a diffusible and stable oxidizing agent, exerts vasodilator function and plays important roles in the physiological regulation of coronary blood flow. In occlusive coronary ischemia, the release of hydrogen peroxide from the microvasculature helps to restore vasomotor function of coronary collateral microvessels with exercise training. However, excessive production and prolonged exposure of microvessels to hydrogen peroxide impairs NO-mediated endothelial function by reducing L-arginine availability through hydroxyl radical-dependent upregulation of arginase. The redox signaling can be a double-edged sword in the microcirculation, which helps tissue survival in one way by improving vasomotor regulation and elicits oxidative stress and tissue injury in the other way by causing vascular dysfunction. The impact of vascular arginase on the development of vasomotor dysfunction associated with angiotensin II receptor activation, hypertension, ischemia-reperfusion, hypercholesterolemia and inflammatory insults is discussed.

  19. Importance of adequate exercise in the detection of coronary heart disease by radionuclide ventriculography

    International Nuclear Information System (INIS)

    Brady, T.J.; Thrall, J.H.; Lo, K.; Pitt, B.

    1980-01-01

    Rest and exercise radionuclide ventriculograms were obtained on 77 symptomatic patients without prior documented coronary artery disease (CAD). Coronary artery disease was present by angiograms in 48. Radionuclide ventriculography (RNV) was abnormal in 41 patients (overall sensitivity 85%). In 29 patients with normal coronary arteries, RNV was normal in 24 (specificity 83%). To determine if the exercise level affects sensitivity, the studies were graded for adequacy of exercise. It was considered adequate if patients developed (a) chest pain, or (b) ST segment depression of at least 1 mm, or (c) if they achieved a pressure rate product greater than 250. Among the 48 patients with coronary artery disease, 35 achieved adequate exercise. Thirty-three had an abnormal RNV (sensitivity 94%). In 13 patients who failed to achieve adequate exercise, RNV was abnormal in eight (sensitivity of only 62%). Some patients with coronary artery disease may have a normal ventricular response at inadequate levels of stress

  20. Anomalous Origin of the Right Coronary Artery from the Left Anterior Descending Coronary Artery in a Patient with Ascending Aortic Aneurysm

    Directory of Open Access Journals (Sweden)

    Ufuk Gürkan

    2012-04-01

    Full Text Available The incidence of coronary artery anomalies has been reported between 0.6 to 1.3% in angiographic series and 0.3% in autopsy series. An isolated single coronary artery (SCA is even a rarer congenital anomaly occurring in approximately 0.02% of the population. The ectopic origin of the right coronary artery (RCA from the left anterior descending (LAD artery is relatively rare and more benign than other types of anomalous origin of the RCAs. We report a case of an adult male patient with SCA anomaly in which the RCA takes off from the mid LAD. To the best of our knowledge, SCA anomaly coinciding with ascending aortic aneurysm which was treated with Bentall operation has never been described before.

  1. Improvement in recuperative gas cycles by means of a heat generator partly by-passing the recuperator. Application to open and closed cycles and to various kinds of energy

    International Nuclear Information System (INIS)

    Tilliette, Z.P.; Pierre, B.

    1979-01-01

    A particular arrangement applicable to open or closed recuperative gas cycles and consisting of a heat generator partly by-passing the low pressure side of the recuperator is proven to enhance advantages of gas cycles for energy production. The cogeneration of both power with a high efficiency owing to the recuperator and high temperature process heat becomes possible and economically attractive. Furthermore, additional possibilities appear for power generation by combined gas and steam or ammonia cycles. In any case the overall utilization coefficient of the primary energy is increased and the combined production of low or medium temperature heat can also be improved. The great operation flexibility of the system for combined energy generation is worth being emphasized: the by-pass arrangement involves no significant change in the operation conditions of the main turbocompressor as the heat output varies. Applications of this arrangement are made to: - open and closed gas cycle, power plants; - fossil, nuclear and solar energies. The overall heat conversion efficiency is tentatively estimated in order to appreciate the energy conversion capability of the investigated power plants

  2. Effect of Heart Rate and Coronary Calcification on the Diagnostic Accuracy of the Dual-Source CT Coronary Angiography in Patients with Suspected Coronary Artery Disease

    International Nuclear Information System (INIS)

    Meng, Lingdong; Cui, Lianqun; Cheng, Yuntao; Wu, Xiaoyan; Tang, Yuansheng; Wang, Yong; Xu, Fayun

    2009-01-01

    To evaluate the diagnostic accuracy of a dual-source computed tomography (DSCT) coronary angiography, with a particular focus on the effect of heart rate and calcifications. One hundred and nine patients with suspected coronary disease were divided into 2 groups according to a mean heart rate ( 400). Next, the effect of heart rate and calcification on the accuracy of coronary artery stenosis detection was analyzed by using an invasive coronary angiography as a reference standard. Coronary segments of less than 1.5 mm in diameter in an American Heart Association (AHA) 15-segment model were independently assessed. The mean heart rate during the scan was 71.8 bpm, whereas the mean Agatston score was 226.5. Of the 1,588 segments examined, 1,533 (97%) were assessable. A total of 17 patients had calcium scores above 400 Agatston U, whereas 50 had heart rates ≥ 70 bpm. Overall the sensitivity, specificity, positive predictive values (PPV) and negative predictive values (NPV) for significant stenoses were: 95%, 91%, 65%, and 99% (by segment), respectively and 97%, 90%, 81%, and 91% (by artery), respectively (n = 475). Heart rate showed no significant impact on lesion detection; however, vessel calcification did show a significant impact on accuracy of assessment for coronary segments. The specificity, PPV and accuracy were 96%, 80%, and 96% (by segment), respectively for an Agatston score less than 100% and 99%, 96% and 98% (by artery). For an Agatston score of greater to or equal to 400 the specificity, PPV and accuracy were reduced to 79%, 55%, and 83% (by segment), respectively and to 79%, 69%, and 85% (by artery), respectively. The DSCT provides a high rate of accuracy for the detection of significant coronary artery disease, even in patients with high heart rates and evidence of coronary calcification. However, patients with severe coronary calcification (> 400 U) remain a challenge to diagnose

  3. Prevalence of Congenital Coronary Artery Anomalies and Variants in 2697 Consecutive Patients Using 64-Detector Row Coronary CTAngiography

    International Nuclear Information System (INIS)

    Shabestari, Abbas Arjmand; Akhlaghpoor, Shahram; Tayebivaljozi, Reza; Fattahi Masrour, Farzaneh

    2012-01-01

    Coronary artery anomalies are not common, but could be very serious. This study determines the frequency of coronary anomalies and normal variants by multi-detector-row computed tomography (MDCT). The results of cardiac MDCT study in 2697 consecutive patients were analyzed retrospectively. Acquisition was performed by a 64-detector row CT machine. Imaging results were assessed by experienced radiologists. Myocardial bridging was by far the most frequent coronary variant (n = 576, 21.3%). Eighty-three subjects (3.1%) showed other coronary anomalies and variants. Anomalies of origination and course of the left main coronary artery (LMCA) were detected in 1.09% of the subjects. The frequency of these anomalies in the right coronary artery (RCA), left circumflex artery (LCx), left anterior descending artery (LAD), posterior descending artery (PDA) and obtuse marginal (OM) artery were 1.24%, 0.33%, 0.1%, 0.07% and 0.03%, respectively. The single coronary pattern was seen in 0.18% and coronary fistulas in 0.07%. Based on the fact that coronary CT-angiography using MDCT can display different coronary anomalies, this study shows similar results to other reports on the subject. Future advances in the performance of CT machines will further improve the quality of CT-based cardiac imaging

  4. Fate of coronary ostial anastomoses after the modified Bentall procedure.

    Science.gov (United States)

    Milano, Aldo D; Pratali, Stefano; Mecozzi, Gianclaudio; Boraschi, Piero; Braccini, Giovanni; Magagnini, Enrico; Bortolotti, Uberto

    2003-06-01

    Introduction of the modified Bentall procedure with the button technique has reduced but not eliminated anastomotic complications in patients receiving a composite aortic conduit. Particularly the true incidence of coronary ostial complications such as stenosis, kinking or pseudoaneurysm formation needs to be assessed. We reviewed 71 patients receiving a composite aortic conduit from November 1993 to November 1999 for chronic aneurysms (n = 51) or aortic dissection (n = 20), 12 of whom had Marfan syndrome. Patients were divided into two groups according to variations in the surgical technique. In group 1 (30 patients; 42%) the classic modified Bentall operation with the button technique was employed whereas in group 2 (41 patients; 58%) some technical modifications were added mainly consisting of a reinforcement suture joining the cut edge of the aortic wall and the prosthetic sewing ring and suture of the coronary buttons with an "endo-button" technique. To detect potential procedure-related complications particularly at the coronary ostia anastomoses follow-up included transthoracic two-dimensional echocardiography every 6 months and computerized tomographic angiography at 12 months or whenever indicated; in 20 patients a magnetic resonance imaging angiography and standard aortography with selective coronary angiography were also added. At a mean follow-up of 49 +/- 19 months anastomotic complications occurred in 4 patients (6%): in 2 a pseudoaneurysm developed at the distal aortic suture line and in 1 a pseudoaneurysm developed at the right coronary ostium after repair of acute aortic dissection; in 1 Marfan patient an aneurysm of the left coronary ostium developed. Such complications were unrelated to the two surgical techniques used in this series for reimplantaion of the coronary ostia. The modified Bentall operation is associated with an extremely low incidence of anastomotic complications particularly at the coronary ostia. More extensive use of new imaging

  5. Operation efficiency increasing of dual-purpose NPP's by means of improving turbine plants

    International Nuclear Information System (INIS)

    Ivanov, V.A.; Borovkov, V.M.; Levit, I.G.; Averbakh, Yu.A.; Titova, I.B.

    1984-01-01

    Ways of operation efficiency increasing power plants for combined electrisity prodUction and centralized heating with WWER-440 reactors and wet-steam heating-condensating turbines are considered. Two variants of floWsheets of by-pass steam distribution permitting to use energy of excess steam in a wide pressure range in the secondary circuit for keeping electric or thermal power of the power unit at a possibly higher level are analyzed. Optimum time of operating cycle prolongation of a heating WWER-440 poWer unit when using the suggested flowsheets with pipelines of by-pass distribution of excess steam covers 16-40 days for the range of change in expenditures at reconstruction for electric power and heat 13.5-17 rub/MWxh and 2-3 rub./MWxh. The maximum time of the reactor operating cycle prolongation for the considered situations makes up 30-80 days

  6. Percutaneous transluminal coronary angioplasty

    International Nuclear Information System (INIS)

    Przybojewski, J.Z.; Weich, H.F.H.

    1984-01-01

    The purpose of this article is to review PTCA, percutaneous transluminal coronary angioplasty, which can be considered to be a truly revolutionary and fairly simple invasive form of intervention to atherosclerotic obstruction. The 'epidemic' of IHD, ischaemic heart disease, in the Republic of South Africa calls for the employment of this technique, which has already been carried out in a few teaching hospitals in this country. Very recently, modified balloon dilatation catheters have been used percutaneously in the non-operative transluminal correction of congenital coarctation of the aorta in infants and children, congenital pulmonary value stenosis, and hypoplasia and stenosis of the pulmonary arteries. It has also been employed for PTCA and for the simultaneous occlusion of coronary-bronchial artery anastomosis using a detachable balloon. The isotopes thallium 201 and technetium 99 were also used in scintiscanning

  7. Anatomical studies of the coronary system in elasmobranchs: II. Coronary arteries in hexanchoid, squaloid, and carcharhinoid sharks.

    Science.gov (United States)

    De Andrés, A V; Muñoz-Chápuli, R; Sans-Coma, V; García-Garrido, L

    1992-07-01

    Coronary artery anatomy was studied in 16 shark species belonging to 9 families of the orders Hexanchiformes, Squaliformes, and Carcharhiniformes. The study included 101 specimens and used an injection-corrosion technique that obtained internal casts of the main trunks and coronary arterial branches. The results showed 2 main patterns of coronary arterial arrangement: the dorsoventral coronary trunk pattern, shared by lamnoid and advanced carcharhinoid sharks, and the lateral coronary trunk pattern, shown by hexanchoid and squaloid sharks. Scyliorhinus and Galeus had intermediate arrangements of their vessels.

  8. Automated processing of first-pass radionuclide angiocardiography by factor analysis of dynamic structures.

    Science.gov (United States)

    Cavailloles, F; Bazin, J P; Capderou, A; Valette, H; Herbert, J L; Di Paola, R

    1987-05-01

    A method for automatic processing of cardiac first-pass radionuclide study is presented. This technique, factor analysis of dynamic structures (FADS) provides an automatic separation of anatomical structures according to their different temporal behaviour, even if they are superimposed. FADS has been applied to 76 studies. A description of factor patterns obtained in various pathological categories is presented. FADS provides easy diagnosis of shunts and tricuspid insufficiency. Quantitative information derived from the factors (cardiac output and mean transit time) were compared to those obtained by the region of interest method. Using FADS, a higher correlation with cardiac catheterization was found for cardiac output calculation. Thus compared to the ROI method, FADS presents obvious advantages: a good separation of overlapping cardiac chambers is obtained; this operator independant method provides more objective and reproducible results. A number of parameters of the cardio-pulmonary function can be assessed by first-pass radionuclide angiocardiography (RNA) [1,2]. Usually, they are calculated using time-activity curves (TAC) from regions of interest (ROI) drawn on the cardiac chambers and the lungs. This method has two main drawbacks: (1) the lack of inter and intra-observers reproducibility; (2) the problem of crosstalk which affects the evaluation of the cardio-pulmonary performance. The crosstalk on planar imaging is due to anatomical superimposition of the cardiac chambers and lungs. The activity measured in any ROI is the sum of the activity in several organs and 'decontamination' of the TAC cannot easily be performed using the ROI method [3]. Factor analysis of dynamic structures (FADS) [4,5] can solve the two problems mentioned above. It provides an automatic separation of anatomical structures according to their different temporal behaviour, even if they are superimposed. The resulting factors are estimates of the time evolution of the activity in each

  9. Indications for coronary angiography

    International Nuclear Information System (INIS)

    Kaltenbach, M.; Vallbracht, C.

    1985-01-01

    Today selective coronary angiography, introduced by Sones in 1957, is used as clinical routine for diagnosing morphological changes in the coronary arteries. Hitherto, more recent techniques such as digital subtraction angiography cannot provide comparable information. Strict criteria for its indication depending on possible therapeutic consequences, have to be applied, although the risk is low with a letality of 0.01 to 0.05 percent. Radionuclear investigations can be used as additional tool in selected cases. The careful indication for coronary angiography usually implies the possible need for coronary bypass graft surgery of balloon angioplasty. (orig./MG) [de

  10. Simultaneous nephrectomy and coronary artery bypass grafting through extended sternotomy

    Directory of Open Access Journals (Sweden)

    Budrikis Algimantas

    2012-08-01

    Full Text Available Abstract Background The advances in surgical techniques, resuscitation and anesthesiology support over the last years have allowed simultaneous thoracic and abdominal operations to be made for cancer and concomitant severe heart vessel disease relieving the patient from several diseases simultaneously and achieving long lasting remission or cure. Clinical case A simultaneous nephrectomy and coronary artery bypass grafting procedure through extended sternotomy is reported. A 63-year-old man with severe coronary artery disease was found to have renal carcinoma. Diagnosis Postoperative pathological investigation of the tumor revealed the presence of renal cell carcinoma pT3a N0 M0, G2. Coronarography revealed advanced three-vessel coronary artery disease. Treatment We successfully performed a simultaneous curative surgery for renal carcinoma and coronary artery bypass graft surgery under cardiopulmonary bypass using a novel technique of extended sternotomy. Simultaneous surgery thus appears to be a beneficial and safe approach for the treatment of coronary artery disease and resectable renal cancer in carefully selected patients.

  11. Relation of coronary vasoreactivity and coronary calcification in asymptomatic subjects with a family history of premature coronary artery disease

    International Nuclear Information System (INIS)

    Pirich, Christian; Leber, Alexander; Knez, Andreas; Bengel, Frank M.; Nekolla, Stephan G.; Schwaiger, Markus; Haberl, Ralph

    2004-01-01

    Electron-beam computed tomography (EBCT) allows non-invasive imaging of coronary calcification and has been promoted as a screening tool for coronary artery disease (CAD) in asymptomatic high-risk subjects. This study assessed the relation of coronary calcifications to alterations in coronary vascular reactivity by means of positron emission tomography (PET) in asymptomatic subjects with a familial history of premature CAD. Twenty-one subjects (mean age 51±10 years) underwent EBCT imaging for coronary calcifications expressed as the coronary calcium score (CCS according to Agatston) and rest/adenosine-stress nitrogen-13 ammonia PET with quantification of myocardial blood flow (MBF) and coronary flow reserve (CFR). The mean CCS was 237±256 (median 146, range 0-915). The CCS was 100 units in 13. As defined by age-related thresholds, 15 subjects had an increased CCS (>75th percentile). Overall mean resting and stress MBF and CFR were 71±16 ml 100 g -1 min -1 , 218±54 ml 100 g -1 min -1 and 3.20±0.77, respectively. Three subjects with CCS ranging from 114 to 451 units had an abnormal CFR (<2.5). There was no relation between CCS and resting or stress MBF or CFR (r=0.17, 0.18 and 0.10, respectively). In asymptomatic subjects a pathological CCS was five times more prevalent than an abnormal CFR. The absence of any close relationship between CCS and CFR reflects the fact that quantitative myocardial perfusion imaging with PET characterises the dynamic process of vascular reactivity while EBCT is a measure of more stable calcified lesions in the arterial wall whose presence is closely related to age. (orig.)

  12. Stagnant loop syndrome resulting from small-bowel irradiation injury and intestinal by-pass

    International Nuclear Information System (INIS)

    Swan, R.W.

    1974-01-01

    Stagnant or blind-loop syndrome includes vitamin B12 malabsorption, steatorrhea, and bacterial overgrowth of the small intestine. A case is presented to demonstrate this syndrome occurring after small-bowel irradiation injury with exaggeration postenterocolic by-pass. Alteration of normal small-bowel flora is basic to development of the stagnant-loop syndrome. Certain strains of bacteria as Bacteriodes and E. coli are capable of producing a malabsorption state. Definitive therapy for this syndrome developing after severe irradiation injury and intestinal by-pass includes antibiotics. Rapid symptomatic relief from diarrhea and improved malabsorption studies usually follow appropriate antibiotic therapy. Recolonization of the loop(s) with the offending bacterial species may produce exacerbation of symptoms. Since antibiotics are effective, recognition of this syndrome is important. Foul diarrheal stools should not be considered a necessary consequence of irradiation injury and intestinal by-pass

  13. Passing and Catching in Rugby.

    Science.gov (United States)

    Namudu, Mike M.

    This booklet contains the fundamentals for rugby at the primary school level. It deals primarily with passing and catching the ball. It contains instructions on (1) holding the ball for passing, (2) passing the ball to the left--standing, (3) passing the ball to the left--running, (4) making a switch pass, (5) the scrum half's normal pass, (6) the…

  14. Determining the Optimal Number of Core Needle Biopsy Passes for Molecular Diagnostics.

    Science.gov (United States)

    Hoang, Nam S; Ge, Benjamin H; Pan, Lorraine Y; Ozawa, Michael G; Kong, Christina S; Louie, John D; Shah, Rajesh P

    2018-03-01

    The number of core biopsy passes required for adequate next-generation sequencing is impacted by needle cut, needle gauge, and the type of tissue involved. This study evaluates diagnostic adequacy of core needle lung biopsies based on number of passes and provides guidelines for other tissues based on simulated biopsies in ex vivo porcine organ tissues. The rate of diagnostic adequacy for pathology and molecular testing from lung biopsy procedures was measured for eight operators pre-implementation (September 2012-October 2013) and post-implementation (December 2013-April 2014) of a standard protocol using 20-gauge side-cut needles for ten core biopsy passes at a single academic hospital. Biopsy pass volume was then estimated in ex vivo porcine muscle, liver, and kidney using side-cut devices at 16, 18, and 20 gauge and end-cut devices at 16 and 18 gauge to estimate minimum number of passes required for adequate molecular testing. Molecular diagnostic adequacy increased from 69% (pre-implementation period) to 92% (post-implementation period) (p < 0.001) for lung biopsies. In porcine models, both 16-gauge end-cut and side-cut devices require one pass to reach the validated volume threshold to ensure 99% adequacy for molecular characterization, while 18- and 20-gauge devices require 2-5 passes depending on needle cut and tissue type. Use of 20-gauge side-cut core biopsy needles requires a significant number of passes to ensure diagnostic adequacy for molecular testing across all tissue types. To ensure diagnostic adequacy for molecular testing, 16- and 18-gauge needles require markedly fewer passes.

  15. Optimization of coronary attenuation in coronary computed tomography angiography using diluted contrast material.

    Science.gov (United States)

    Kawaguchi, Naoto; Kurata, Akira; Kido, Teruhito; Nishiyama, Yoshiko; Kido, Tomoyuki; Miyagawa, Masao; Ogimoto, Akiyoshi; Mochizuki, Teruhito

    2014-01-01

    The purpose of this study was to evaluate a personalized protocol with diluted contrast material (CM) for coronary computed tomography angiography (CTA). One hundred patients with suspected coronary artery disease underwent retrospective electrocardiogram-gated coronary CTA on a 256-slice multidetector-row CT scanner. In the diluted CM protocol (n=50), the optimal scan timing and CM dilution rate were determined by the timing bolus scan, with 20% CM dilution (5ml/s during 10s) being considered suitable to achieve the target arterial attenuation of 350 Hounsfield units (HU). In the body weight (BW)-adjusted protocol (n=50, 222mg iodine/kg), only the optimal scan timing was determined by the timing bolus scan. The injection rate and volume in the timing bolus scan and real scan were identical between the 2 protocols. We compared the means and variations in coronary attenuation between the 2 protocols. Coronary attenuation (mean±SD) in the diluted CM and BW-adjusted protocols was 346.1±23.9 HU and 298.8±45.2 HU, respectively. The diluted CM protocol provided significantly higher coronary attenuation and lower variance than did the BW-adjusted protocol (P<0.05, in each). The diluted CM protocol facilitates more uniform attenuation on coronary CTA in comparison with the BW-adjusted protocol.  

  16. Giant Coronary Artery Aneurysm Causing Acute Anterior Myocardial Infarction

    Directory of Open Access Journals (Sweden)

    Ahmet Yanık

    2016-01-01

    Full Text Available A 70-year-old man with hypertension was admitted to our coronary ICU with acute anterior MI. Emergent primary PCI was planned and coronary angiography was performed. LAD artery was totally occluded in the proximal segment just after a huge 32 × 26 mm sized aneurysm. Emergent CABG operation was performed in 75 minutes because of multivessel disease including the RCA and left circumflex artery. Aneurysm was ligated and coronary bypass was performed using LIMA and saphenous grafts. The postoperative course of the patient was uneventful. He was discharged with medical therapy including ASA, clopidogrel, and atorvastatin. He was asymptomatic at his polyclinic visit in the first month.

  17. Resistin Enhances Inflammatory Cytokine Production in Coronary Artery Tissues by Activating the NF-κB Signaling

    Directory of Open Access Journals (Sweden)

    Fang Gao

    2016-01-01

    Full Text Available Purpose. Kawasaki disease (KD is a systemic vasculitis and is a leading cause of coronary artery lesions (CALs in childhood. Our previous study has shown higher levels of serum Resistin in KD patients with coronary aneurysm. This study aimed at examining the association of Resistin with inflammatory cytokine expression in mouse model of coronary arteritis and determining the potential mechanisms. Methods. C57BL/6 mice were injected with Lactobacillus cell wall extract (LCWE to induce coronary arteritis. The relative levels of Resistin, TNF-α, IL-1β, and MMP-9 expression and inflammatory infiltrates in the coronary arteries were determined longitudinally by quantitative RT-PCR, ELISA, and histology. The effect of TLR4 and NF-κB activation on Resistin-induced TNF-α and IL-1β expression in human coronary artery endothelium cells (HCAECs was examined by quantitative RT-PCR. Results. Higher levels of Resistin, TNF-α, IL-1β, and MMP-9 expression were associated with the degrees of inflammatory infiltrates in the coronary artery walls of the LCWE-injected mice. Resistin enhanced TNF-α and IL-1β expression in HCAECs at 18 or 24 hours after stimulation. Pretreatment with anti-TLR4 attenuated Resistin-enhanced IL-1β, but not TNF-α, expression and pretreatment with parthenolide or QNZ demolished Resistin-enhanced TNF-α expression in HACECs. Pretreatment with parthenolide, but not QNZ, blocked Resistin-enhanced IL-1β expression in HCAECs. Conclusion. Resistin may enhance inflammation by cross-talking with TLR4/NF-κB signaling during the development of coronary arteritis in mice.

  18. Correlations Between the Gradient of Contrast Density, Evaluated by Cardio CT, and Functional Significance of Coronary Artery Stenosis

    Directory of Open Access Journals (Sweden)

    Orzan Marius

    2016-06-01

    Full Text Available Background: Assessment of the hemodynamic significance of a coronary artery stenosis is a challenging task, being extremely important for the establishment of indication for revascularization in atherosclerotic coronary artery stenosis. The aim of this study was to evaluate the role of a new marker reflecting the functional significance of a coronary artery stenosis, represented by the attenuation degree of contrast density along the stenosis by Coronary CT.

  19. Coronary artery anomalies in Turner Syndrome.

    Science.gov (United States)

    Viuff, Mette H; Trolle, Christian; Wen, Jan; Jensen, Jesper M; Nørgaard, Bjarne L; Gutmark, Ephraim J; Gutmark-Little, Iris; Mortensen, Kristian H; Gravholt, Claus Højbjerg; Andersen, Niels H

    Congenital heart disease, primarily involving the left-sided structures, is often seen in patients with Turner Syndrome. Moreover, a few case reports have indicated that coronary anomalies may be more prevalent in Turner Syndrome than in the normal population. We therefore set out to systematically investigate coronary arterial anatomy by computed tomographic coronary angiography (coronary CTA) in Turner Syndrome patients. Fifty consecutive women with Turner Syndrome (mean age 47 years [17-71]) underwent coronary CTA. Patients were compared with 25 gender-matched controls. Coronary anomaly was more frequent in patients with Turner Syndrome than in healthy controls [20% vs. 4% (p = 0.043)]. Nine out of ten abnormal cases had an anomalous left coronary artery anatomy (absent left main trunk, n = 7; circumflex artery originating from the right aortic sinus, n = 2). One case had a tubular origin of the right coronary artery above the aortic sinus. There was no correlation between the presence of coronary arterial anomalies and karyotype, bicuspid aortic valve, or other congenital heart defects. Coronary anomalies are highly prevalent in Turner Syndrome. The left coronary artery is predominantly affected, with an absent left main coronary artery being the most common anomaly. No hemodynamically relevant coronary anomalies were found. Copyright © 2016 Society of Cardiovascular Computed Tomography. All rights reserved.

  20. Milrinone infusion: A therapeutic option in coronary vasospasm after primary percutaneous transluminal coronary angioplasty

    Directory of Open Access Journals (Sweden)

    Singh Amarpal

    2009-01-01

    Full Text Available A 42-year-old male presented to the emergency department with acute chest pain. The electrocardiogram revealed inferior wall myocardial infarction. Emergency coronary angiography revealed total occlusion of the distal right coronary artery with thrombus. Patient was taken up for primary percutaneous coronary angioplasty with stenting of distal right coronary artery. Six hours following the procedure, the patient developed re-elevation of ST-segment in inferior leads of electrocardiogram and subsequent haemodynamic instability. Repeat coronary angiography revealed patent stent and coronary artery spasm in proximal part, which was relieved by intracoronary injection of nitroglycerine. After an hour, the patient re-developed symptoms of chest pain along with bradycardia, hypotension and ST segment elevation. Intravenous infusion of nitroglycerine did not improve the condition but produced persistent hypotension. Infusion of milrinone was then started. Over time, normalisation of electrocardiogram occurred. The patient was discharged in stable condition. This case suggests that milrinone may be effective in alleviating coronary artery spasm when the use of other agents fails

  1. Coronary artery disease confined to secondary branches of the left coronary system

    International Nuclear Information System (INIS)

    Iskandrian, A.S.; Klein, B.L.; Segal, B.L.; Kimbiris, D.; Bemis, C.E.

    1981-01-01

    Among 3,000 patients studied by coronary arteriography during a 4-year period, 31 patients (1%) had coronary artery disease limited to a diagonal branch of the left anterior descending (15 patients), marginal branch of the left circumflex (10 patients), or to both branches (6 patients). Ten patients had 50-69% and twenty-one had greater than or equal to 70% diameter narrowing. The suitability for grafting was noted in 20 patients as judged by the caliber and distribution of the diseased branches. Collaterals were noted in seven patients. Disease was present in 28 men and 3 women (age range 38-70 years). At least one major coronary risk factor was present in 27 patients. Angina was noted in 27 patients; prior myocardial infarction was noted in 5 patients by history and in 4 by ECG. The left ventriculogram was normal in 22 patients and showed mild segmental asynergy in 9; ejection fraction was normal in all. Exercise ECGs were positive in 12 of 25 patients; exercise 201thallium scans were positive in 13. All patients responded to medical therapy. In conclusion, among the population of patients who undergo catheterization, coronary branch disease is rare. The clinical findings are indistinguishable from patients with major coronary disease. Prognosis remains benign and patients respond to medical therapy

  2. Magnetic navigation in a coronary phantom: experimental results.

    Science.gov (United States)

    García-García, Héctor M; Tsuchida, Keiichi; Meulenbrug, Hans; Ong, Andrew T L; Van der Giessen, Willem J; Serruys, Patrick W

    2005-11-01

    The objective was to investigate the efficacy of a magnetic navigation system (MNS) in a coronary phantom. The number of coronary interventional procedures performed is steadily increasing with the availability of new devices to treat more complex lesions. Vessel tortuosity remains an important limiting factor in percutaneous coronary intervention. The MNS can orient the tip of magnetized wire. The coronary phantom is a representation of the coronary tree. Two operators using both a magnetic wire and a standard wire, measured the procedural time (PT), the fluoroscopic time (FT) and the radiation exposure/area product (DAP) required to navigate through to fourteen segments. Ten wire advancements were performed per segment. In all but two segments, the PT was significantly longer using magnetic navigation than using manual navigation. The median FT in the left main artery (LMA) - first septal segment was 7 seconds vs. 18 seconds, with magnetic and manual navigation respectively, (p=0.05); in the LMA - obtuse marginal segment the median FT was 15 seconds with magnetic navigation vs. 29.5 seconds with manual navigation, (p=0.01); in the segment from proximal right coronary artery (RCA1) to the acute marginal branch, the median FT was 8 seconds with magnetic vs. 11 seconds with manual navigation, (p=0.05); and in the RCA1 -posterior descending segment the median FT was 9.5 seconds with magnetic vs. 15 seconds with manual navigation, (p=0.006). The MNS facilitates wire access to distal segments in a coronary phantom, with a reduction in FT and radiation exposure using magnetic navigation in tortuous segments.

  3. The clinical research of off-pump coronary artery bypass grafting by small incision at the left chest.

    Science.gov (United States)

    Xiao, L-B; Zhang, Y-H; Zhou, J-W; Yang, M; Ling, Y-P; Gao, Z-S; Wang, Y-S

    2016-01-01

    To explore the clinical value of off-pump coronary artery bypass grafting by small incision at the left chest, and develop a better surgical regimen for coronary heart disease patients. 201 coronary heart disease patients who need coronary artery bypass grafting were required and randomly divided into 2 groups including a control group and an observation group. There were 107 cases in the control group who received coronary bypass grafting by extracorporeal circulation; there were 103 cases in the observation group who received off-pump coronary bypass grafting by small incision at the left chest. The duration of the mechanism ventilation, length of stay in ICU, hospitalization time, postoperative drainage volume, and the occurrence rate of complications were recorded and compared. The duration of mechanism ventilation, length of stay in ICU, hospitalization time and postoperative drainage volume in the control group were (19.21 ± 1.33) hours, (5.08 ± 0.57) days, (21.20 ± 2.34) days and (997.68 ± 96.35) mL, which were (7.73 ± 0.74) hours, (2.83 ± 0.16) days, (15.67 ± 1.18) days and (901.53 ± 89.32) mL in the observation group respectively, with statistical difference between the two groups (pdisease, pulmonary infection, perioperative cardiac infarction and mortality did not display a significant difference between the two groups (p > 0.05). Off-pump coronary artery bypass grafting by small incision at the left chest is a surgical method with less injury and fast recovery, which can be used as the preferred therapeutical method for the coronary heart disease patients who need coronary artery bypass grafting.

  4. Microstructural and mechanical responses to various rolling speeds determined in multi-pass break-down rolling of AZ31B alloy

    Science.gov (United States)

    Jia, Weitao; Tang, Yan; Ning, Fangkun; Le, Qichi; Cui, Jianzhong

    2018-04-01

    Different rolling operations of as-cast AZ31B alloy were performed under different rolling speed (18 ∼ 72 m min‑1) and rolling pass conditions at 400 °C. Microstructural studies, tensile testing and formability evaluation relevant to each rolling operation were investigated. For 1-pass rolling, coarse average grain size (CAGS) region gradually approached the center layer as the rolling speed increased. Moreover, twins, shear bands and coarse-grain structures were the dominant components in the microstructure of plates rolled at 18, 48 and 72 m min‑1, respectively, indicating the severe deformation inhomogeneity under the high reduction per pass condition. For 2-pass rolling and 4-pass rolling, dynamic recrystallization was observed to be well and CAGS region has substantially disappeared, indicating the significant improvement in deformation uniformity and further the grain homogenization under the conditions. Microstructure uniformity degree of 2-pass rolled plates did not vary much as the rolling speed varied. On this basis, shear band distribution dominated the deformation behavior during the uniaxial tension of the 2-pass rolled plates. However, microstructure uniformity accompanied by twin distribution played a leading role in stretching the 4-pass rolled plates.

  5. Coronary reserve of the right ventricle evaluated by double dose Tl-201 scintigraphy

    International Nuclear Information System (INIS)

    Sugihara, Hiroki; Adachi, Haruhiko; Nakagawa, Hiroaki

    1985-01-01

    Thallium-201 double dose scintigraphy was applied to exercise to estimate the coronary blood flow reserve of the left and right ventricles and this was compared with the degree of coronary artery stenosis. As an index of coronary reserve we measured the rate of change of blood flow distribution (ΔF) calculated from the change in myocardial radioactivity following thallium-201 injections, once at rest and once during exercise. With submaximal exercise the increases in ΔF of the left ventricle were less in patients with ischemic heart disease than in the control subjects, and were less as the number of diseased coronary vessels increased. The increases of ΔF of the right ventricle were less in patients with stenosis of the proximal portion of the right coronary artery than in patients without stenosis and in the control subjects. The more severe the stenosis of the proximal portion of the right coronary artery, the smaller the ΔF of the right ventricle. These results indicate that evaluation of the ΔF in the left and right ventricles is useful in estimating coronary artery stenosis. (author)

  6. Coronary Plaque Volume and Composition Assessed by Computed Tomography Angiography in Patients With Late-Onset Major Depression

    DEFF Research Database (Denmark)

    Devantier, Torben Albert; Nørgaard, Bjarne Linde; Ovrehus, Kristian Altern

    2013-01-01

    Background: Depression is a stronger predictor for the onset of or death from clinical coronary artery disease than traditional cardiovascular risk factors. The association between depression and coronary artery disease has previously been investigated in non-contrast enhanced computed tomography...... studies with conflicting results. The aim of this study was to further elucidate the depression-coronary artery disease relation by use of coronary computed tomography angiography. Methods: The calcified and noncalcified coronary plaque volumes were determined by semiautomatic volumetric quantification...... with controls (14% vs. 7%, p = 0.044). Correspondingly, having depression was associated with an increased calcified plaque proportion of 11.3 [95% confidence interval: 2.63-20.1; p = 0.012] percentage points after adjustment for demographics and cardiovascular risk factors. Conclusion: The proportion...

  7. Subclinical Coronary Plaque Burden in Asymptomatic Relatives of Patients With Documented Premature Coronary Artery Disease

    DEFF Research Database (Denmark)

    Christiansen, Morten Krogh; Jensen, Jesper Møller; Bøtker, Hans Erik

    Introduction: A family history of premature coronary artery disease (CAD) is a well-known risk factor for adverse coronary events with age of onset being inversely related to the degree of heritability. Hypothesis: We hypothesized that asymptomatic first degree relatives, of patients with premature...... CAD, suffer a high burden of subclinical coronary atherosclerosis. Methods: First degree relatives, aged 30-65 years, of patients with a documented coronary revascularization procedure before the age of 40 years, were invited to participate in the study. Participants were matched by age, sex...... and absence of a family history, with patients referred for coronary CT angiography (CTA) because of atypical angina or non-anginal chest pain. A pooled blinded analysis was performed. The main outcome measure was the number of plaque-affected coronary segments. Results: 88 relatives and 88 symptomatic...

  8. Intravenous coronary angiography by electron beam computed tomography : a clinical evaluation

    NARCIS (Netherlands)

    Rensing, B J; Bongaerts, A; van Geuns, R J; van Ooijen, P; Oudkerk, M; de Feyter, P J

    1998-01-01

    BACKGROUND: -Noninvasive detection of coronary stenoses with electron beam CT (EBCT) after intravenous injection of contrast medium has recently emerged. We sought to determine the diagnostic accuracy of EBCT angiography in the clinical setting using conventional coronary angiography as the "gold

  9. Prevalence of Coronary Artery Intramyocardial Course in a Large Population of Clinical Patients Detected by Multislice Computed Tomography Coronary Angiography

    Energy Technology Data Exchange (ETDEWEB)

    De Rosa, R.; Sacco, M.; Tedeschi, C.; Pepe, R.; Capogrosso, P.; Montemarano, E.; Rotondo, A.; Runza, G.; Midiri, M.; Cademartiri, F. (UO di Radiologia, Ospedale San Gennaro, Napoli (Italy))

    2008-10-15

    Background: Intramyocardial course, an inborn coronary anomaly, is defined as a segment of a major epicardial coronary artery that runs intramurally through the myocardium; in particular, we distinguish myocardial bridging, in which the vessel returns to an epicardial position after the muscle bridge, and intramyocardial course, which is described as a vessel running and ending in the myocardium. Purpose: To evaluate the prevalence of myocardial bridging and intramyocardial course of coronary arteries as defined by multidetector computed tomography (MDCT) angiography. Material and Methods: The study population consisted of 242 consecutive patients (211 men, 31 women; mean age 59+-6 years) with atypical chest pain admitted to our hospital between December 2004 and September 2006. All MDCT examinations were performed using a 16-detector-row scanner (Aquilion 16 CFX; Toshiba Medical System, Tokyo, Japan). Patients with heart rate above 65 bpm received 50 mg atenolol orally for 3 days prior to the MDCT scan, or they increased their usual therapy with beta-blockers, in order to obtain a prescan heart rate <60 bpm. Curved multiplanar and 3D volume reconstructions were performed to explore coronary anatomy. Results: In 235 patients, the CT scan was successful and images were appropriate for evaluation. The prevalence of myocardial bridging and intramyocardial course of coronary arteries was 18.7% (47 cases) in our patient population. In 30 segments (63.8%), the vessels ran and ended in the myocardium. In the remaining 17 segments (36.2%), the vessels returned to an epicardial position after the muscle bridge. We found no difference in the prevalence of this inborn coronary anomaly when comparing different clinical characteristics of the study population (sex, age, body-mass index [BMI], etc.). The mean length of the subepicardial artery was 7 mm (range 5-12 mm), and the mean depth in the diastolic phase was 1.9 mm (range 1.2-2.3 mm). There was no significant difference of

  10. A rare anomaly: Double right coronary artery

    Directory of Open Access Journals (Sweden)

    Dursun Çayan Akkoyun

    2013-01-01

    Full Text Available Coronary artery anomalies are rare anomalies. Theseare usually asymptomatic and are discovered incidentally.Double right coronary artery (RCA is a rare coronaryartery anomaly. Although there is controversy aboutidentification and classification of double RCA, it is oftena benign condition, but it can be complicated by atherosclerosisand can lead to serious conditions such asmyocardial infarction (MI and may be accompanied byother anomalies. In our case, double RCA were detectedin coronary angiography for acute anterior MI, and in thenext session successful percutaneous coronary interventionwas performed.Key words: Coronary anomaly, coronary angiography,coronary stenosis

  11. A study of estimating cutting depth for multi-pass nanoscale cutting by using atomic force microscopy

    International Nuclear Information System (INIS)

    Lin, Zone-Ching; Hsu, Ying-Chih

    2012-01-01

    This paper studies two models for estimating cutting depth of multi-pass nanoscale cutting by using an atomic force microscopy (AFM) probe. One estimates cutting depth for multi-pass nanoscale cutting by using regression equations of nanoscale contact pressure factor (NCP factor) while the other uses equation of specific down force energy (SDFE). This paper proposes taking a diamond-coated probe of AFM as the cutting tool to carry out multi-pass nanoscale cutting experiments on the surface of sapphire substrate. In the process of experimentation, different down forces are set, and the probe shape of AFM is known, then using each down force to multi-pass cutting the sapphire substrate. From the measured experimental data of a central cutting depth of the machining groove by AFM, this paper calculates the specific down force energy of each down force. The experiment results reveal that the specific down force energy of each case of multi-pass nanoscale cutting for different down forces under a probe of AFM is close to a constant value. This paper also compares the nanoscale cutting results from estimating cutting depths for each pass of multi-pass among the experimental results and the calculating results obtained by the two theories models. It is found that the model of specific down force energy can calculate cutting depths for each nanoscale cutting pass by one equation. It is easier to use than the multi-regression equations of the nanoscale contact pressure factor. Besides, the estimations of cutting depth results obtained by the model of specific down force energy are closer to that of the experiment results. It shows that the proposed specific down force energy model in this paper is an acceptable model.

  12. Noninvasive detection of coronary artery disease by dipyridamole-loading 201thallium myocardial scintigraphy

    International Nuclear Information System (INIS)

    Hamashige, Naohisa; Doi, Yoshinori; Yonezawa, Yoshihiro; Odawara, Hiroaki; Ozawa, Toshio; Akagi, Naoki; Yoshida, Shoji; Maeda, Tomoho

    1986-01-01

    Fifty patients with suspected coronary artery disease (CAD) were given i.v. infusion of 0.568 mg/kg of dipyridamole (DP) for 4 min in the supine position, and were loaded by stepping. Myocardial DP scanning (DP scintigraphy) was then performed with i.v. injection of 3 mCi of Tl-201 chloride. Findings were compared with those of coronary angiography and treadmill ECG. DP scintigraphy had higher sensitivity (90 %) and specificity (95 %) than treadmill ECG (76 % and 67 %) in diagnosing a ≥ 75 % coronary stenosis. Twenty nine patients had significant CAD: Reversible defects were associated with chest pain in 79 %, and with ST depression in 76 %. Not only relative differences in blood flow between the normal and diseased sites but also ischemia was suggested to be responsible for these defects. Increased rate pressure product by DP scintigraphy was slight (34 %) compared with that by treadmill ECG (105 %), suggesting a strong involvement of redistribution of coronary blood flow in the occurrence of ischemia. Increased myocardial oxygen consumption due to stepping was considered as the cause of ischemia as well, because the incidence of chest pain and ST depression was higher than previously reported. Chest pain and ST depression improved by i.v. injection of aminophylline. (Namekawa, K.)

  13. Coronary tortuosity: a long and winding road.

    NARCIS (Netherlands)

    Zegers, E.S.; Meursing, B.T.J.; Oude Ophuis, A.J.M.

    2007-01-01

    Coronary tortuosity is a phenomenon often encountered by cardiologists performing coronary angiography. The aetiology and clinical importance of coronary tortuosity are still unclear. Coronary tortuosity without fixed atherosclerotic stenosis in patients with angina pectoris and an abnormal exercise

  14. Wavenumber–domain separation of rail contribution to pass-by noise

    NARCIS (Netherlands)

    Zea, Elias; Manzari, Luca; Squicciarini, Giacomo; Feng, Leping; Thompson, David; Arteaga, Ines Lopez

    2017-01-01

    In order to counteract the problem of railway noise and its environmental impact, passing trains in Europe must be tested in accordance to a noise legislation that demands the quantification of the noise generated by the vehicle alone. However, for frequencies between about 500 Hz and 1600 Hz, it

  15. Evaluation of hemodynamic significance of coronary fistulae. Diagnostic integration between coronary angiography and stress/rest myocardial scintigraphy

    International Nuclear Information System (INIS)

    Rubini, G.; Sebastiani, M.

    2000-01-01

    after percutaneous coronary angiography of the right coronary artery stenosis. Due to the onset of angina stress/rest 99m Tc sestamibi myocardial perfusion single photon emission tomography was performed to evaluate stress/rest perfusion (75 Watt, 125 b/m, 88% max frequency, arterial pressure 200 mmHg, double max product 25000 with ST depression of 1.5 mm in V1-V4) and identified an irreversible perfusion defect due to infarction and a reversible perfusion defect of the anterior wall and apex due to ischemia caused by the anomalous flow through the coronary fistula. The correspondence between the site of the coronary artery where the fistula originates, identified by coronary angiography, and the reversible perfusion defects, identified by stress/rest 99m Tc sestamibi myocardial perfusion single photon emission tomography, indicates that the anomalous flow through the fistula may cause myocardial ischemia. The irreversible perfusion defects of the inferior wall are the result of right coronary artery subocclusive stenosis. Coronary fistulae cause myocardial ischemia only in a small number of patients. Data obtained from single photon emission tomography in evaluation stress/rest myocardial perfusion, correlated with data from coronary angiography, have shown that changes in patients with terminal coronary anomalies may be due to different coronary diseases: ischemia to anomalous flow through the fistula and myocardial infarction to subocclusive right coronary artery stenosis. Stress/rest 99m Tc sestamibi single photon emission tomography for the evaluation of myocardial perfusion is a reliable means of assessing the functional importance of the terminal coronary anomalies detected by coronary angiography. Evaluation of the hemodynamic importance of the coronary fistulae is indispensable in programming corrective surgery [it

  16. Off-pump coronary artery bypass surgery in severe left ventricular dysfunction.

    Science.gov (United States)

    Azarfarin, Rasoul; Pourafkari, Leili; Parvizi, Rezayat; Alizadehasl, Azin; Mahmoodian, Roghaiyeh

    2010-02-01

    Our aim was to examine hospital outcomes of coronary artery bypass surgery in patients with and without left ventricular dysfunction, with regard to the surgical technique (off- or on-pump). Between March 2007 and March 2008, 689 consecutive patients underwent isolated first-time coronary artery bypass; 127 had ejection fractions fractions >30% (group 2). Data of preoperative risk profiles and hospital outcomes were collected prospectively. Off-pump operations were performed in 49 (38.6%) patients in group 1 and 196 (34.9%) in group 2. The incidences of infectious, neurologic, and cardiac complications postoperatively were significantly higher in group 1. In multivariate analysis, preoperative ejection fraction operations, but no significant difference in mortality was observed between those undergoing off-pump or conventional surgery in either group. Off-pump surgery helped to limit the increased morbidity rate after coronary bypass in patients with ventricular dysfunction.

  17. Subclinical coronary atherosclerosis by multi-scan axial tomography and its association with hyperglycemia

    International Nuclear Information System (INIS)

    Buchaca Faxas, Emilio F; Bencomo Rodriguez, Llimia; Bermudez Rojas, Sergio

    2010-01-01

    A study was conducted to assess the usefulness of multi-scan axial tomography techniques to detect, in a subclinical stage, the coronary damage in patients presenting with diabetes mellitus (DM) to describe the frequency of asymptomatic atherosclerotic affection and its potential association with the fasting and postprandial hyperglycemia. In study were included 59 patients with type 2 diabetes to compare the results of coronary calcium determination with the findings of angiography by multi-scan axial computed tomography (CAT-M). There was a concordance of a 44.1% between both studies, as well as a predominance of soft plaques in the 55.9 % of patients. The 42.4 % showed a narrowing of arterial lumen, which was significant in the 16.5 % of total. A high figure of patients with hyperglycemia had coronary damage compared to those ills with a good glycemia control (p = 0.024). This relation was more evident with the postprandial hyperglycemia (= 0.016). Hyperglycemia had a high opportunity (5.99 times) to detect coronary lesions by TAC-C compared to other major atherosclerosis risk factors like the high blood pressure, smoking, dyslipemias expressed in a significant way (p 0.045). We conclude that Angio TAC-C and Calcio Score techniques are useful to detect lesions of coronary arteries in patients with type 2 diabetes mellitus without symptoms of myocardial ischemia, which was associated to presence of a hyperglycemia, fundamentally postprandial

  18. Association between epicardial fat volume and coronary plaques diagnosed by multislice computed tomography

    Directory of Open Access Journals (Sweden)

    José A. Morán Quijada

    2016-01-01

    Full Text Available Introduction: Coronary atherosclerotic disease is a major cause of death in Cuba and elsewhere. The volume of epicardial fat is considered a new cardiovascular risk factor because of its association with coronary atherogenesis.Objective: To determine, by multislice computed tomography, the association between epicardial fat volume and the presence of coronary atherosclerotic plaques.Method: A descriptive study was conducted with a universe of 130 patients with chest pain suggestive of ischemic heart disease, of which 117 were selected by opinion sampling. These patients underwent a calcium score study, a coronary angiography and a measurement of the epicardial fat volume.Results: Male patients predominated (54.7% and those aged 60-69 years (32.5%. A high volume of epicardial fat was found in 51.3% of patients, affecting 52.8% of women; 78.9% of patients with a calcium score between 100 and 399 UH had a high volume of epicardial fat, just as 71.2% of those with plaques and 100% of those with 4 or 5 plaques; 41% of patients had various types of plaque, which were mainly located in the anterior descending artery (88.1%.Conclusions: The measurement of the volume of epicardial fat is a useful tool to estimate the presence of coronary disease. When it was high, it was associated with older age, female gender and the presence of a higher calcium score, more plaques, more injuries and a greater involvement of the anterior descending artery.

  19. The PASS project architectural model

    International Nuclear Information System (INIS)

    Day, C.T.; Loken, S.; Macfarlane, J.F.

    1994-01-01

    The PASS project has as its goal the implementation of solutions to the foreseen data access problems of the next generation of scientific experiments. The architectural model results from an evaluation of the operational and technical requirements and is described in terms of an abstract reference model, an implementation model and a discussion of some design aspects. The abstract reference model describes a system that matches the requirements in terms of its components and the mechanisms by which they communicate, but does not discuss policy or design issues that would be necessary to match the model to an actual implementation. Some of these issues are discussed, but more detailed design and simulation work will be necessary before choices can be made

  20. Coronary Artery Anomalies in Animals

    Directory of Open Access Journals (Sweden)

    Brian A. Scansen

    2017-04-01

    Full Text Available Coronary artery anomalies represent a disease spectrum from incidental to life-threatening. Anomalies of coronary artery origin and course are well-recognized in human medicine, but have received limited attention in veterinary medicine. Coronary artery anomalies are best described in the dog, hamster, and cow though reports also exist in the horse and pig. The most well-known anomaly in veterinary medicine is anomalous coronary artery origin with a prepulmonary course in dogs, which limits treatment of pulmonary valve stenosis. A categorization scheme for coronary artery anomalies in animals is suggested, dividing these anomalies into those of major or minor clinical significance. A review of coronary artery development, anatomy, and reported anomalies in domesticated species is provided and four novel canine examples of anomalous coronary artery origin are described: an English bulldog with single left coronary ostium and a retroaortic right coronary artery; an English bulldog with single right coronary ostium and transseptal left coronary artery; an English bulldog with single right coronary ostium and absent left coronary artery with a prepulmonary paraconal interventricular branch and an interarterial circumflex branch; and a mixed-breed dog with tetralogy of Fallot and anomalous origin of all coronary branches from the brachiocephalic trunk. Coronary arterial fistulae are also described including a coronary cameral fistula in a llama cria and an English bulldog with coronary artery aneurysm and anomalous shunting vessels from the right coronary artery to the pulmonary trunk. These examples are provided with the intent to raise awareness and improve understanding of such defects.

  1. Adenosine stress cardiovascular magnetic resonance with variable-density spiral pulse sequences accurately detects coronary artery disease: initial clinical evaluation.

    Science.gov (United States)

    Salerno, Michael; Taylor, Angela; Yang, Yang; Kuruvilla, Sujith; Ragosta, Michael; Meyer, Craig H; Kramer, Christopher M

    2014-07-01

    Adenosine stress cardiovascular magnetic resonance perfusion imaging can be limited by motion-induced dark-rim artifacts, which may be mistaken for true perfusion abnormalities. A high-resolution variable-density spiral pulse sequence with a novel density compensation strategy has been shown to reduce dark-rim artifacts in first-pass perfusion imaging. We aimed to assess the clinical performance of adenosine stress cardiovascular magnetic resonance using this new perfusion sequence to detect obstructive coronary artery disease. Cardiovascular magnetic resonance perfusion imaging was performed during adenosine stress (140 μg/kg per minute) and at rest on a Siemens 1.5-T Avanto scanner in 41 subjects with chest pain scheduled for coronary angiography. Perfusion images were acquired during injection of 0.1 mmol/kg Gadolinium-diethylenetriaminepentacetate at 3 short-axis locations using a saturation recovery interleaved variable-density spiral pulse sequence. Significant stenosis was defined as >50% by quantitative coronary angiography. Two blinded reviewers evaluated the perfusion images for the presence of adenosine-induced perfusion abnormalities and assessed image quality using a 5-point scale (1 [poor] to 5 [excellent]). The prevalence of obstructive coronary artery disease by quantitative coronary angiography was 68%. The average sensitivity, specificity, and accuracy were 89%, 85%, and 88%, respectively, with a positive predictive value and negative predictive value of 93% and 79%, respectively. The average image quality score was 4.4±0.7, with only 1 study with more than mild dark-rim artifacts. There was good inter-reader reliability with a κ statistic of 0.67. Spiral adenosine stress cardiovascular magnetic resonance results in high diagnostic accuracy for the detection of obstructive coronary artery disease with excellent image quality and minimal dark-rim artifacts. © 2014 American Heart Association, Inc.

  2. Assessment of coronary artery stent patency by electron-beam CT

    International Nuclear Information System (INIS)

    Knollmann, Friedrich D.; Felix, Roland; Moeller, Joerg; Gebert, Axel; Bethge, Christian

    2004-01-01

    Following coronary angioplasty and stent implantation, restenosis remains common and its outcome difficult to predict. We set out to determine the diagnostic accuracy of electron-beam computed tomography (EBCT) for the non-invasive detection of stent obstruction. In a prospective, blinded investigation, we included 152 coronary artery segments in 117 patients treated with a stent implant. All segments were evaluated by a dynamic EBCT study that depicted contrast bolus passage distal to the stent and a CT angiographic study of the entire coronary arteries. It was found that delayed contrast enhancement in the distal segment correlated with angiographic stent obstruction (Spearman's rank correlation, P=0.008), while all other indicators of stent occlusion did not correlate with angiographic diagnosis. However, direct comparison of patients with obstruction of less vs. more than 75% of luminal diameter did not yield any statistically significant differences of distal enhancement delay, and for the detection of >90% occlusion, the sensitivity was 72% at a specificity of 60%. Although delayed contrast enhancement distal to the stent upon EBCT did correlate with angiographical obstruction, the correlation did not suffice to appear clinically satisfactory. (orig.)

  3. Assessment of coronary artery stent patency by electron-beam CT

    Energy Technology Data Exchange (ETDEWEB)

    Knollmann, Friedrich D.; Felix, Roland [Department of Radiology, Charite, Campus Virchow-Klinikum, Humboldt-University, Augustenburger Platz 1, 13353, Berlin (Germany); Moeller, Joerg; Gebert, Axel; Bethge, Christian [Department of Cardiology, Juedisches Krankenhaus, Berlin (Germany)

    2004-08-01

    Following coronary angioplasty and stent implantation, restenosis remains common and its outcome difficult to predict. We set out to determine the diagnostic accuracy of electron-beam computed tomography (EBCT) for the non-invasive detection of stent obstruction. In a prospective, blinded investigation, we included 152 coronary artery segments in 117 patients treated with a stent implant. All segments were evaluated by a dynamic EBCT study that depicted contrast bolus passage distal to the stent and a CT angiographic study of the entire coronary arteries. It was found that delayed contrast enhancement in the distal segment correlated with angiographic stent obstruction (Spearman's rank correlation, P=0.008), while all other indicators of stent occlusion did not correlate with angiographic diagnosis. However, direct comparison of patients with obstruction of less vs. more than 75% of luminal diameter did not yield any statistically significant differences of distal enhancement delay, and for the detection of >90% occlusion, the sensitivity was 72% at a specificity of 60%. Although delayed contrast enhancement distal to the stent upon EBCT did correlate with angiographical obstruction, the correlation did not suffice to appear clinically satisfactory. (orig.)

  4. Multislice CT coronary angiography: effect of sublingual nitroglycerine on the diameter of coronary arteries

    International Nuclear Information System (INIS)

    Dewey, M.; Hamm, B.; Hoffmann, H.

    2006-01-01

    Purpose: to investigate the influence of sublingual glycerol trinitrate (1.2 mg, Nitrate [nitroglycerine], Nitrolingual N spray) on the coronary artery diameter on multislice computed tomography (MSCT) coronary angiography. Materials and methods: out of our database of patients who underwent MSCT (slice thickness of 0.5 mm, Aquilion, Toshiba) coronary angiography between July 2003 and November 2005 (950 patients) we retrospectively identified patients with follow-up examinations who received Nitrate for one examination while another examination was performed without Nitrate (10 patients). Another 10 patients who underwent two MSCT examinations with sublingual Nitrate administration were randomly selected from this database to serve as control group. For the resulting 40 MSCT examinations, blinded MSCT datasets were prepared, which were randomly evaluated by a reader blinded to the patient information and whether or not Nitrate had been given. The proximal coronary artery diameters were measured for the left main coronary artery (LMA), the left anterior descending coronary artery (LAD), the left circumflex coronary artery (LCX), and the right coronary artery (RCA) in all 40 datasets, resulting in altogether 160 measurements. Results: the proximal diameters of all four coronary arteries were significantly larger on the MSCT coronary angiograms obtained after sublingual administration of Nitrate compared with the examinations in the same 10 patients without Nitrate (p < 0.001). The average diameters without and with Nitrate for the LMA, LAD, LCX, and RCA were 4.3 ± 1.1 vs. 4.8 ± 0.9 mm (12% increase, p < 0.005), 3.0 ± 0.6 vs. 3.5 ± 0.5 mm (17% increase, p < 0.001), 2.7 ± 0.6 vs. 3.2 ± 0.7 mm (19% increase, p < 0.005), and 2.9 ± 0.9 vs. 3.5 ± 0.7 mm (21% increase, p < 0.005), respectively. In the control group of 10 patients who underwent two MSCT coronary angiographies after sublingual Nitrate, no significant difference in the proximal diameter of all four

  5. Metropolitan all-pass and inter-city quantum communication network.

    Science.gov (United States)

    Chen, Teng-Yun; Wang, Jian; Liang, Hao; Liu, Wei-Yue; Liu, Yang; Jiang, Xiao; Wang, Yuan; Wan, Xu; Cai, Wei-Qi; Ju, Lei; Chen, Luo-Kan; Wang, Liu-Jun; Gao, Yuan; Chen, Kai; Peng, Cheng-Zhi; Chen, Zeng-Bing; Pan, Jian-Wei

    2010-12-20

    We have demonstrated a metropolitan all-pass quantum communication network in field fiber for four nodes. Any two nodes of them can be connected in the network to perform quantum key distribution (QKD). An optical switching module is presented that enables arbitrary 2-connectivity among output ports. Integrated QKD terminals are worked out, which can operate either as a transmitter, a receiver, or even both at the same time. Furthermore, an additional link in another city of 60 km fiber (up to 130 km) is seamless integrated into this network based on a trusted relay architecture. On all the links, we have implemented protocol of decoy state scheme. All of necessary electrical hardware, synchronization, feedback control, network software, execution of QKD protocols are made by tailored designing, which allow a completely automatical and stable running. Our system has been put into operation in Hefei in August 2009, and publicly demonstrated during an evaluation conference on quantum network organized by the Chinese Academy of Sciences on August 29, 2009. Real-time voice telephone with one-time pad encoding between any two of the five nodes (four all-pass nodes plus one additional node through relay) is successfully established in the network within 60 km.

  6. Coronary Artery Disease

    DEFF Research Database (Denmark)

    Christiansen, Morten Krogh

    2017-01-01

    A family history of coronary artery disease (CAD) is an important risk factor for adverse coronary events, in particular if the disease has an early onset. The risk of CAD is influenced by genetic and environmental factors with a greater genetic contribution earlier in life. Through recent years......), and to characterize and quantify subclinical atherosclerosis in their relatives. Furthermore, the aim was to explore the impact of common genetic risk variants on the age of onset, familial clustering and disease severity. In study I, 143 patients with early- onset CAD were recruited from the Western Denmark Heart...... Registry and risk factor control was evaluated. The study revealed that risk factors are common in early-onset CAD and that a large room for risk factor improvement remains. In study II, we used coronary computed tomography angiography to compare the coronary plaque burden and characteristics between 88...

  7. Automatic detection of coronary arterial branches from X-ray angiograms

    International Nuclear Information System (INIS)

    Lu, Shan; Eiho, Shigeru

    1992-01-01

    This paper describes a method to trace the coronary arterial boundaries automatically from x-ray angiograms. We developed an automatic procedure to detect the edges of an artery with its branches. The edge point is evaluated by a function based on smoothing differential operator on a searching line which is obtained by using the continuous properties of the arterial edges. Thus the boundary points along the artery are detected automatically. If there exists a branch on the boundary, it can be detected automatically. This information about the branch is stored on the stack of the search information and will be used to detect the branch artery. In our edge detection process, the required user interaction is only the manual definition of a starting point for the search, the direction of the search and the range for search. We tested this method on some images generated by a computer with different stenoses and on a coronary angiogram. These results show that this method is useful for analyzing coronary angiograms. (author)

  8. Bilateral carotid endarterectomy combined with myocardial revascularization during the same surgical act

    Directory of Open Access Journals (Sweden)

    Mulinari Leonardo Andrade

    2000-01-01

    Full Text Available The best surgical approach for the treatment of patients with severe cerebral artery disease and simultaneous serious coronary artery disease still remains controversial. In this report we present a case of a 72-year-old female patient admitted to the hospital with unstable angina. Triple coronary artery obstructive disease and severe bilateral carotid artery stenosis were diagnosed. A combined, simultaneous surgical procedure was performed. After total circulatory by-pass with a membrane oxygenator, the patient's body temperature was lowered to 32°C. During the cool-down period, three proximal anastomoses of segments of autologous saphenous veins were performed in the ascending aorta. Immediately afterwards, bilateral carotid endarterectomy was performed, followed by three distal anastomoses to coronary arteries. The patient showed a satisfactory post-operative outcome. It was concluded that the combination of moderate hypothermia, hemodilution with appropriate hemodynamic control, as used in this patient, was an effective method of cerebral protection. The simultaneous approach of carotid endarterectomy and coronary artery by-pass surgery should be seen as a safe option for the treatment of this type of patient.

  9. Mid-term follow-up outcomes of 2-staged hybrid coronary revascularization compared with off-pump coronary artery bypass for patients with multivessel coronary artery disease.

    Science.gov (United States)

    Wu, Song; Ling, Yunpeng; Fu, Yuanhao; Zhang, Lufeng; Yang, Hang; Guo, Lijun; Gao, Wei; Wan, Feng

    2017-06-01

    Two-staged hybrid coronary revascularization (HCR) is a novel procedure in selected patients with multivessel coronary artery disease. However, few studies are available on the mid-term or long-term outcomes of this 2-staged procedure as compared to off-pump coronary artery bypass (OPCAB). To compare in-hospital and mid-term follow-up outcomes of 2-staged HCR with OPCAB in patients with multivessel coronary artery disease. The present retrospective study analyzed the data from 73 patients who underwent the 2-staged HCR (HCR group) during 2012-2014 at the heart center. Three hundred and eighty-three patients who underwent conventional OPCAB by the same surgeon were selected for the comparative analysis performed on in-hospital and mid-term follow-up outcomes between the two groups. No significant difference was observed in the preoperative outcome between the two groups. The HCR group had a shorter operation duration (152.9 ±43.8 vs. 262.6 ±51.8 min, p < 0.05), less bleeding (558.6 ±441.3 vs. 1035.5 ±613.3 ml, p < 0.05), shorter mechanical ventilation (9.4 ±7.4 vs. 19.0 ±18.3 h, p < 0.05), and less blood transfusion (12 (16.4%) vs. 200 (52.2%), p < 0.05). The mean follow-up duration was 25.0 ±9.6 months in the HCR group and 22.8 ±10.6 months in the OPCAB group. The incidence of major adverse cardiac or cerebrovascular events (MACCE) was similar in both groups (4 (5.5%) vs. 10 (2.8%), p = 0.408). The estimated 3-year survival was similar in both groups (log-rank χ 2 = 1.041, p = 0.308). The 2-staged HCR is a safe and effective surgical procedure and may offer similar mid-term follow-up outcomes to OPCAB.

  10. Fractional Flow Reserve Assessment of a Significant Coronary Stenosis Masked by a Downstream Serial Lesion

    Directory of Open Access Journals (Sweden)

    Lawrence Yu-Min Liu

    2016-01-01

    Full Text Available Fractional flow reserve (FFR has been recognized as an effective tool to determine functional significance in intermediate coronary lesions and FFR-guided percutaneous coronary intervention (PCI improves clinical outcomes. However, hemodynamic interaction between serial stenoses within one coronary artery complicates the assessment of functional severity of each individual lesion. We present a case in which FFR measurement by intracoronary bolus injection of adenosine helps to make appropriate revascularization decision in serial stenoses when the procedures are performed systemically and properly.

  11. Deficiency of sex hormones does not affect 17-ß-estradiol-induced coronary vasodilation in the isolated rat heart.

    Science.gov (United States)

    Santos, R L; Lima, J T; Rouver, W N; Moysés, M R

    2016-01-01

    The relaxation of coronary arteries by estrogens in the coronary vascular beds of naive and hypertensive rats has been well described. However, little is known about this action in gonadectomized rats. We investigated the effect of 17-ß-estradiol (E2) in coronary arteries from gonadectomized rats, as well as the contributions of endothelium-derived factors and potassium channels. Eight-week-old female and male Wistar rats weighing 220-300 g were divided into sham-operated and gonadectomized groups (n=9-12 animals per group). The baseline coronary perfusion pressure (CPP) was determined, and the vasoactive effects of 10 μM E2 were assessed by bolus administration before and after endothelium denudation or by perfusion with NG-nitro-L-arginine methyl ester (L-NAME), indomethacin, clotrimazole, L-NAME plus indomethacin, L-NAME plus clotrimazole or tetraethylammonium (TEA). The CPP differed significantly between the female and sham-operated male animals. Gonadectomy reduced the CPP only in female rats. Differences in E2-induced relaxation were observed between the female and male animals, but male castration did not alter this response. For both sexes, the relaxation response to E2 was, at least partly, endothelium-dependent. The response to E2 was reduced only in the sham-operated female rats treated with L-NAME. However, in the presence of indomethacin, clotrimazole, L-NAME plus indomethacin or L-NAME plus clotrimazole, or TEA, the E2 response was significantly reduced in all groups. These results highlight the importance of prostacyclin, endothelium-derived hyperpolarizing factor, and potassium channels in the relaxation response of coronary arteries to E2 in all groups, whereas nitric oxide may have had an important role only in the sham-operated female group.

  12. Diagnosing coronary artery disease after a positive coronary computed tomography angiography

    DEFF Research Database (Denmark)

    Nissen, L; Winther, S; Westra, J

    2018-01-01

    Aims: Perfusion scans after coronary computed tomography angiography (CCTA) in patients with suspected coronary artery disease (CAD) may reduce unnecessary invasive coronary angiographies (ICAs). However, the diagnostic accuracy of perfusion scans after primary CCTA is unknown. The aim...

  13. Clinical and angiographic profile of patients with markedly elevated coronary calcium scores (≥1000) detected by electron beam computed tomography

    International Nuclear Information System (INIS)

    Almeda, Francis Q.; Shah, Rima; Senter, Shaun; Kason, Thomas T.; Haynie, Justin; Calvin, James E.; Kavinsky, Clifford J.; Snell, R. Jeffrey; Schaer, Gary L.; McLaughlin, Vallerie V.

    2004-01-01

    Objective: The objective of this study was to determine the clinical and angiographic profile of patients with extremely high coronary artery calcium scores (CACS; ≥1000) by electron beam computed tomography (EBCT). Methods: All patients at Rush University Medical Center who had a calcium score ≥1000 and a coronary angiogram performed from 1997 to 2002 were identified using a prospectively collected database. The baseline demographics, symptom status, and degree of coronary stenosis by angiography and subsequent rate of coronary intervention were compared with that of patients with calcium scores <1000. Results: The clinical and angiographic profile of patients with severe coronary calcification, detected by EBCT, revealed that patients with scores ≥1000 had a significantly higher prevalence of coronary stenosis ≥50% compared with patients with scores <1000 (97% vs. 57%, P<.001). The group with CACS ≥1000 was more likely to be male (90% vs. 75%, P=.027) and was older (64±8 vs. 59±10, P=.001) compared with the group with less severe calcification. Although there was a significantly higher rate of luminal stenosis detected by coronary angiography in the cohort with CACS ≥1000, there was no difference in subsequent percutaneous coronary intervention (PCI) and utilization of intracoronary stents between the two groups. Conclusions: A markedly elevated coronary calcium score (≥1000) is correlated with increasing age and is associated with an increased likelihood of coronary stenosis ≥50%. However, the decision to perform coronary angiography in patients with severe coronary calcification should not be based solely on these findings, but should remain primarily dependent on the degree of ischemia detected by clinical and functional assessment

  14. Serial assessment of left ventricular function following coronary bypass surgery by radionuclide angiocardiography

    International Nuclear Information System (INIS)

    Kawasuji, Michio; Sawa, Shigeharu; Sakakibara, Naoki; Iwa, Takashi; Taki, Junichi; Bunko, Hisashi

    1988-01-01

    The serial change in left ventricular function was investigated by radionuclide angiocardiography in 25 patients undergoing coronary artery bypass grafting (CABG). Multiple gated equilibrium blood pool imaging was performed at rest before, and at 1, 2 and 4 weeks after the operation and also during exercise on a supine bicycle ergometer before and 4 weeks after surgery. Global ejection fraction at rest was unchanged after CABG while peak ejection rate increased significantly at 1 and 2 weeks (p < 0.01 and p < 0.05 respectively) after the operation. Peak filling rate at rest was generally unchanged after surgery but peak filling rate during the first third of diastole at rest decreased significantly at 1 and 2 weeks (p < 0.01 and p < 0.05). After CABG, the increases in ejection fraction and peak ejection rate with exercise were significantly greater than those values measured before surgery. The increases, due to exercise, in peak filling rate and peak filling rate during the first third of diastole were unchanged after the operation. Radionuclide angiocardiography affords a safe, noninvasive, and highly reproducible procedure for serially assessing ventricular function in patients undergoing CABG. Our study revealed early diastolic dysfunction within 2 weeks of surgery and that CABG abolished abnormalities in left ventricular function induced by exercise. (author)

  15. Optical coherence tomography following percutaneous coronary intervention with Excimer laser coronary atherectomy

    Energy Technology Data Exchange (ETDEWEB)

    Rawlins, John, E-mail: john.rawlins@doctors.net.uk; Talwar, Suneel; Green, Mark; O’Kane, Peter

    2014-01-15

    The indications for Excimer laser coronary atherectomy (ELCA) have been refined in modern interventional practice. With the expanding role for optical coherence tomography (OCT) providing high-resolution intra-coronary imaging, this article examines the appearance of the coronary lumen after ELCA. Each indication for ELCA is discussed and illustrated with a clinical case, followed by detailed analysis of the OCT imaging pre and post ELCA. The aim of the article is to provide information to interventional cardiologists to facilitate decision making during PCI, when ELCA has been used as part of the interventional strategy.

  16. A Dynamic Continuation-Passing Style for Dynamic Delimited Continuations

    DEFF Research Database (Denmark)

    Biernacki, Dariusz; Danvy, Olivier; Millikin, Kevin Scott

    2005-01-01

    We present a new abstract machine that accounts for dynamic delimited continuations. We prove the correctness of this new abstract machine with respect to a pre-existing, definitional abstract machine. Unlike this definitional abstract machine, the new abstract machine is in defunctionalized form......, which makes it possible to state the corresponding higher-order evaluator. This evaluator is in continuation+state passing style and threads a trail of delimited continuations and a meta-continuation. Since this style accounts for dynamic delimited continuations, we refer to it as `dynamic continuation......-passing style.' We show that the new machine operates more efficiently than the definitional one and that the notion of computation induced by the corresponding evaluator takes the form of a monad. We also present new examples and a new simulation of dynamic delimited continuations in terms of static ones....

  17. Coronary hemodynamics in vasospastic angina

    International Nuclear Information System (INIS)

    Matsumura, Kentaro; Kubota, Shinobu; Serizawa, Takashi; Nakase, Emiko; Kawai, Ichiro; Saito, Takayuki

    1991-01-01

    To evaluate the coronary circulation and myocardial perfusion dynamics, we performed left coronary digital subtraction angiography (DSA) in 35 patients with vasospastic angina. The left coronary circulation time (CCT) measured from the proximal left coronary artery to the coronary sinus was 5.77±0.86 sec, and the left epicardial conducting artery transmission time (CAT) measured from the proximal left coronary artery to the apical area was 2.65±0.82 sec in normal controls. The CCT and CAT were significantly prolonged in patients with vasospastic angina, indicating that the coronary peripheral vascular resistance is probably greater after the cessation of nitrates and Ca ++ -antagonists. After the intracoronary injection of ergonovine malate, the CCT was slightly shortened, but the apical T 1/2 was significantly prolonged in patients with vasospastic angina. This suggested that coronary vasospasm is present not only in the epicardial arteries but also in coronary arteries with peripheral resistance. These phenomena were not observed in normal controls. We performed left coronary DSA after conventional left coronary cineangiography. When the CCT exceeded 6.7 sec, we considered that the coronary circulation was significantly impaired. We concluded that the coronary DSA is very useful for evaluating abnormal coronary circulation in patients with vasospastic angina during myocardial perfusion. (author)

  18. Successful treatment of coronary artery pseudoaneurysm by graft stent, which developed after the implantation of bare metal stent

    Directory of Open Access Journals (Sweden)

    Utku Şenol

    2013-03-01

    Full Text Available Although coronary artery pseudoaneurysm which couldoccur following percutaneous coronary interventions is arare complication, it can be mortal. As soon as the pseudoaneurysmis diagnosed, it should be treated by percutaneousintervention or surgery. Graft stent implantationis a preferred treatment for appropriate patients. In thiscase report, we presented a successful treatment of coronaryartery pseudoaneurysm by graft stent; which developedafter the implantation of bare metal stent into theleft anterior descending coronary artery. J Clin Exp Invest2013; 4 (1: 126-129Key words: Coronary artery, pseudoaneurysm, graft stent

  19. The safety and feasibility of guidezilla catheter in complex coronary interventions and an observational study.

    Science.gov (United States)

    Ma, Jianying; Hou, Lei; Qian, Juying; Ge, Lei; Zhang, Feng; Chang, Shufu; Xu, Rende; Qin, Qing; Ge, Junbo

    2017-10-01

    The monorail Guidezilla guide extension catheter was designed to provide additional backup and facilitate device delivery in percutaneous coronary intervention (PCI) for complex coronary anatomy such as chronic total occlusion (CTO), extreme vessel tortuosity, diseased bypass grafts, and anomalous coronary arteries, among others.The present retrospective, single-center study included 188 consecutive patients who underwent PCI using the Guidezilla catheter from March 2015 to August 2016. Study outcomes were rates of target lesion crossing success, procedural success, and complications.The Guidezilla catheter was used most commonly in PCI of CTOs (45%) and heavy proximal calcification (37%), followed by tortuosity (10%), previously deployed proximal stents (4%), and coronary artery anomaly (4%). The right coronary artery (48%) was most commonly intervened followed by the left ascending (35%) and left circumflex (17%) arteries. Rates of target lesion crossing success and procedural success were both 99%, with one device-related periprocedural complication, namely proximal vessel dissection secondary to deep insertion which was successfully treated with stent implantation. Ninety percent of PCI were performed and completed successfully by radial access.In a single center with experienced operators, the use of the Guidezilla guide extension catheter in PCI of complex coronary anatomy performed mostly via radial artery access appeared safe and efficacious, and greatly facilitated device delivery.

  20. Coronary arterio-venous fistula associated acute coronary syndrome: A case-report and review of literature

    Directory of Open Access Journals (Sweden)

    V.H. Contreras-Gutiérrez

    2017-01-01

    Full Text Available A 56-year-old woman with no medical history presented to the emergency department complaining of oppressive chest pain of three hours of duration triggered by walking. An electrocardiogram (ECG performed at hospital admission showed ST-segment depression and T-wave inversion in left precordial and inferior leads. Serum troponin I levels were above the normal values. Non ST-segment elevation acute coronary syndrome (NSTEACS was diagnosed and an invasive approach with a percutaneous coronary intervention was performed. No obstructive coronary lesions were observed. However a tortuous coronary fistula emerging from the left-anterior descending coronary artery to the pulmonary artery was observed. Coronary arterio-venous fistulas are present in 0.002% of the general population and in 0.25% of patients undergoing cardiac catheterization for any cause. Most of them are asymptomatic. Ischemic symptoms may develop but are infrequent in patients with no atherosclerotic disease.

  1. Rest period duration of the coronary arteries: Implications for magnetic resonance coronary angiography

    International Nuclear Information System (INIS)

    Shechter, Guy; Resar, Jon R.; McVeigh, Elliot R.

    2005-01-01

    Magnetic resonance (MR) and computed tomography coronary imaging is susceptible to artifacts caused by motion of the heart. The presence of rest periods during the cardiac and respiratory cycles suggests that images free of motion artifacts could be acquired. In this paper, we studied the rest period (RP) duration of the coronary arteries during a cardiac contraction and a tidal respiratory cycle. We also studied whether three MR motion correction methods could be used to increase the respiratory RP duration. Free breathing x-ray coronary angiograms were acquired in ten patients. The three-dimensional (3D) structure of the coronary arteries was reconstructed from a biplane acquisition using stereo reconstruction methods. The 3D motion of the arterial model was then recovered using an automatic motion tracking algorithm. The motion field was then decomposed into separate cardiac and respiratory components using a cardiac respiratory parametric model. For the proximal-to-middle segments of the right coronary artery (RCA), a cardiac RP (<1 mm 3D displacement) of 76±34 ms was measured at end systole (ES), and 65±42 ms in mid-diastole (MD). The cardiac RP was 80±25 ms at ES and 112±42 ms at MD for the proximal 5 cm of the left coronary tree. At end expiration, the respiratory RP (in percent of the respiratory period) was 26±8% for the RCA and 27±17% for the left coronary tree. Left coronary respiratory RP (<0.5 mm 3D displacement) increased with translation (32% of the respiratory period), rigid body (51%), and affine (79%) motion correction. The RCA respiratory RP using translational (27%) and rigid body (33%) motion correction were not statistically different from each other. Measurements of the cardiac and respiratory rest periods will improve our understanding of the temporal and spatial resolution constraints for coronary imaging

  2. Contemporary sex differences among patients with acute coronary syndrome treated by emergency percutaneous coronary intervention.

    Science.gov (United States)

    Wada, Hideki; Ogita, Manabu; Miyauchi, Katsumi; Tsuboi, Shuta; Konishi, Hirokazu; Shitara, Jun; Kunimoto, Mitsuhiro; Sonoda, Taketo; Iso, Takashi; Ebina, Hideki; Aoki, Eriko; Kitamura, Kenichi; Tamura, Hiroshi; Suwa, Satoru; Daida, Hiroyuki

    2017-10-01

    Acute coronary syndrome (ACS) is an important cause of mortality and morbidity in the general population. Recent advances in percutaneous coronary intervention (PCI) and optimal medical treatment have helped to improve the prognosis of patients with ACS. The previous reports indicated that women with ACS have a higher risk of adverse outcomes. However, sex differences in clinical outcomes with contemporary coronary revascularization and medical therapy for ACS have not been elucidated. We analyzed data from 676 consecutive patients with ACS (female, n = 166; male, n = 510) who were treated by emergency PCI between 2011 and 2014 at Juntendo Shizuoka Hospital. The patients were grouped according to sex. We defined major adverse cardiovascular events as a composite of all-cause death and ACS recurrence at 1 year and compared rates of major adverse cardiac events (MACE) between the groups. Women were older (75.4 ± 11.0 vs. 66.2 ± 12.2 years) and had a higher rate of multi-vessel disease, chronic kidney disease, and Killip IV at presentation. The cumulative rate of MACE at 1 year was significantly higher among women than men (17.5 vs. 10.2 %, p = 0.02, log-rank test). However, the association between women and a higher risk of MACE was attenuated after adjusting for age (HR 1.25, 95 % CI 0.77-2.00, p = 0.36) and other variables (HR 0.93, 95 % CI 0.36-2.44, p = 0.88). Adjustment for age and other risk factors attenuated sex differences in mid-term clinical outcomes among patients with ACS after emergency PCI.

  3. Improved assessment of functional severity of coronary artery stenosis by analysis of combined intracoronary pressure and flow velocity signals

    NARCIS (Netherlands)

    Nolte, F.

    2014-01-01

    Coronary artery disease (CAD) accounts for almost 2 million deaths per year within the EU. CAD is often characterized by focal narrowing of epicardial arteries, limiting coronary arterial flow and myocardial perfusion. Treatment of critical lesions by percutaneous coronary intervention (PCI) can be

  4. Appearance of microvascular obstruction on high resolution first-pass perfusion, early and late gadolinium enhancement CMR in patients with acute myocardial infarction

    Directory of Open Access Journals (Sweden)

    Redwood Simon

    2009-08-01

    Full Text Available Abstract Background The presence and extent of microvascular obstruction (MO after acute myocardial infarction can be measured by first-pass gadolinium-enhanced perfusion cardiovascular magnetic resonance (CMR or after gadolinium injection with early or late enhancement (EGE/LGE imaging. The volume of MO measured by these three methods may differ because contrast agent diffusion into the MO reduces its apparent extent over time. Theoretically, first-pass perfusion CMR should be the most accurate method to measure MO, but this technique has been limited by lower spatial resolution than EGE and LGE as well as incomplete cardiac coverage. These limitations of perfusion CMR can be overcome using spatio-temporal undersampling methods. The purpose of this study was to compare the extent of MO by high resolution first-pass k-t SENSE accelerated perfusion, EGE and LGE. Methods 34 patients with acute ST elevation myocardial infarction, treated successfully with primary percutaneous coronary intervention (PPCI, underwent CMR within 72 hours of admission. k-t SENSE accelerated first-pass perfusion MR (7 fold acceleration, spatial resolution 1.5 mm × 1.5 mm × 10 mm, 8 slices acquired over 2 RR intervals, 0.1 mmol/kg Gd-DTPA, EGE (1–4 minutes after injection with a fixed TI of 440 ms and LGE images (10–12 minutes after injection, TI determined by a Look-Locker scout were acquired. MO volume was determined for each technique by manual planimetry and summation of discs methodology. Results k-t SENSE first-pass perfusion detected more cases of MO than EGE and LGE (22 vs. 20 vs. 14, respectively. The extent of MO imaged by first-pass perfusion (median mass 4.7 g, IQR 6.7 was greater than by EGE (median mass 2.3 g, IQR 7.1, p = 0.002 and LGE (median mass 0.2 g, IQR 2.4, p = 0.0003. The correlation coefficient between MO mass measured by first-pass perfusion and EGE was 0.91 (p Conclusion The extent of MO following acute myocardial infarction appears larger on

  5. Recovery of distal coronary flow reserve in LAD and LCx after Y-Graft intervention assessed by transthoracic echocardiography

    Science.gov (United States)

    2010-01-01

    Background Y- graft (Y-G) is a graft formed by the Left Internal Mammary Artery (LIMA) connected to the Left Anterior Descending Artery (LAD) and by a free Right Internal Mammary Artery (RIMA) connected to LIMA and to a Marginal artery of Left Circumflex Artery (LCx). Aim of the work was to study the flow of this graft during a six months follow-up to assess whether the graft was able to meet the request of all the left coronary circulation, and to assess whether it could be done by evaluation of coronary flow reserve (CFR). Methods In 13 consecutive patients submitted to Y-G (13 men), CFR was measured in distal LAD and in distal LCx from 1 week after , every two months, up to six months after operation (a total of 8 tests for each patient) by means of transthoracic echocardiography (TTE) and Adenosine infusion (140 mcg/kg/min for 3-6 min). A Sequoia 256, Acuson-Siemens, was used. Contrast was used when necessary (Levovist 300 mg/ml solution at a rate of 0,5-1 ml/min). Max coronary flow diastolic velocity post-/pre-test ≥2 was considered normal CFR. Results Coronary arteriography revealed patency of both branches of Y-G after six months. Accuracy of TTE was 100% for LAD and 85% for LCx. Feasibility was 100% for LAD and 85% for LCx. CFR improved from baseline in LAD (2.21 ± 0.5 to 2.6 ± 0.5, p = 0.03) and in LCx (1.7 ± 1 to 2.12 ± 1, p = 0.05). CFR was under normal at baseline in 30% of patients vs 8% after six months in LAD (p = 0.027), and in 69% of patients vs 30% after six months in LCx (p = 0.066). Conclusion CFR in Y-G is sometimes reduced in both left territories postoperatively but it improves at six months follow-up. A follow-up can be done non-invasively by TTE and CFR evaluation. PMID:20716357

  6. Exercise left ventricular performance in patients with chest pain, ischemic-appearing exercise electrocardiograms, and angiographically normal coronary arteries

    International Nuclear Information System (INIS)

    Berger, H.J.; Sands, M.J.; Davies, R.A.; Wackers, F.J.; Alexander, J.; Lachman, A.S.; Williams, B.W.; Zaret, B.L.

    1981-01-01

    Left ventricular performance was evaluated using first-pass radionuclide angiocardiography in 31 patients with chest pain, an ischemic-appearing exercise electrocardiogram, and angiographically normal coronary arteries at rest and during maximal upright bicycle exercise. 201 Tl imaging was done in all patients after treadmill exercise and in selected patients after ergonovine provocation. Resting left ventricular performance was normal in all patients. An abnormal ejection fraction response to exercise was detected in 12 of 31 patients. Regional dysfunction was present during exercise in four patients, all of whom also had abnormal global responses. Three of these 12 patients and two additional patients had exercise-induced 201 Tl perfusion defects. In all nine patients who underwent ergonovine testing, there was no suggestion of coronary arterial spasm. Thus, left ventricular dysfunction during exercise, in the presence of normal resting performance, was found in a substantial number of patients with chest pain, an ischemic-appearing exercise electrocardiogram, and normal coronary arteries

  7. Single left coronary ostium and an anomalous prepulmonic right coronary artery in 2 dogs with congenital pulmonary valve stenosis.

    Science.gov (United States)

    Visser, Lance C; Scansen, Brian A; Schober, Karsten E

    2013-06-01

    A coronary artery anomaly characterized by the presence of a single left coronary ostium with absence of the right coronary ostium and an anomalous prepulmonic right coronary artery course was observed in two dogs with concurrent congenital pulmonary valve stenosis. This unique coronary artery anatomy is similar to the previously described single right coronary ostium with anomalous prepulmonic left coronary artery, the so-called type R2A anomaly, in that an anomalous coronary artery encircles the pulmonary valve annulus. Both dogs of this report, a boxer and an English bulldog, were of breeds known to be at risk for the type R2A anomaly. As such, veterinarians should be aware that the echocardiographic presence of a left coronary ostium in a dog with pulmonary valve stenosis does not exclude the possibility of a prepulmonic coronary artery anomaly that may enhance the risk of complications during balloon pulmonary valvuloplasty. A descriptive naming convention for coronary artery anomalies in dogs is also presented, which may be preferable to the older coding classification scheme. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Feasibility of a Modified E-PASS and POSSUM System for Postoperative Risk Assessment in Patients with Spinal Disease.

    Science.gov (United States)

    Chun, Dong Hyun; Kim, Do Young; Choi, Sun Kyu; Shin, Dong Ah; Ha, Yoon; Kim, Keung Nyun; Yoon, Do Heum; Yi, Seong

    2018-04-01

    This retrospective case control study aimed to evaluate the feasibility of using Estimation of Physiological Ability and Surgical Stress (E-PASS) and Physiological and Operative Severity Score for the enumeration of Mortality and Morbidity (POSSUM) systems in patients undergoing spinal surgical procedures. Degenerative spine disease has increased in incidence in aging societies, as has the number of older adult patients undergoing spinal surgery. Many older adults are at a high surgical risk because of comorbidity and poor general health. We retrospectively reviewed 217 patients who had undergone spinal surgery at a single tertiary care. We investigated complications within 1 month after surgery. Criteria for both skin incision in E-PASS and operation magnitude in the POSSUM system were modified to fit spine surgery. We calculated the E-PASS and POSSUM scores for enrolled patients, and investigated the relationship between postoperative complications and both surgical risk scoring systems. To reinforce the predictive ability of the E-PASS system, we adjusted equations and developed modified E-PASS systems. The overall complication rate for spinal surgery was 22.6%. Forty-nine patients experienced 58 postoperative complications. Nineteen major complications, including hematoma, deep infection, pleural effusion, progression of weakness, pulmonary edema, esophageal injury, myocardial infarction, pneumonia, reoperation, renal failure, sepsis, and death, occurred in 17 patients. The area under the receiver operating characteristic curve (AUC) for predicted postoperative complications after spine surgery was 0.588 for E-PASS and 0.721 for POSSUM. For predicted major postoperative complications, the AUC increased to 0.619 for E-PASS and 0.842 for POSSUM. The AUC of the E-PASS system increased from 0.588 to 0.694 with the Modified E-PASS equation. The POSSUM system may be more useful than the E-PASS system for estimating postoperative surgical risk in patients undergoing

  9. Clinical evaluation of coronary territory map by using unfolded map of Tl-201 myocardial SPECT

    International Nuclear Information System (INIS)

    Uehara, Toshiisa; Nishimura, Tsunehiko; Katafuchi, Tetsuro; Yamagami, Hidetoshi; Kumita, Shinichirou; Hayashida, Kohei; Hayashi, Makoto

    1990-01-01

    Coronary territory map was developed on unfolded map of exercise Tl-201 myocardial SPECT. Each coronary territory was determined by summing the each unfolded map of 54 cases of single vessel disease respectively, and standardizing with normal pattern obtained from normal patients. The diagnostic accuracy of coronary territory map to identify the diseased coronary artery was analyzed in 104 clinical cases and was compared with that of planar and SPECT visual diagnosis, simple unfolded map (raw map) and extent and severity map. The results were as follows. (1) Territory map showed excellent diagnostic accuracy in single or double vessel disease, especially in diagnosis of left circumflex coronary artery lesion. (2) In triple vessel disease, the diagnostic accuracy of territory map or other unfolded maps was 30% at best, and was inferior to planar or SPECT visual analysis. The cause of this inferiority seemed that the quantitatively analyzed map had no information about the degree of Tl-uptake into lung or myocardium, which give useful information in visual diagnosis. (3) The diagnostic agreement ratio in two observers was the highest in territory map diagnosis, so that the territory map diagnosis seemed to be the most objective one. (4) The unfolded map diagnosis with apical display obtained from long-axis tomogram was useful to diagnose left anteior descending coronary (LAD) lesion, which improve not only the sensitivity of LAD but also specificity of right coronary artery single vessel disease. (author)

  10. Diagnostic performance of coronary CT angiography, stress dual-energy CT perfusion, and stress perfusion single-photon emission computed tomography for coronary artery disease: Comparison with combined invasive coronary angiography and stress perfusion cardiac MRI

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Hyun Woo; Ko, Sung Min; Hwang, Hweung Kon; So, Young; Yi, Jeong Geun [Konkuk University Medical Center, Research Institute of Biomedical Science, Konkuk University School of Medicine, Seoul (Korea, Republic of); Lee, Eun Jeong [Dept. of Nuclear Medicine, Seoul Medical Center, Seoul (Korea, Republic of)

    2017-06-15

    To investigate the diagnostic performance of coronary computed tomography angiography (CCTA), stress dual-energy computed tomography perfusion (DE-CTP), stress perfusion single-photon emission computed tomography (SPECT), and the combinations of CCTA with myocardial perfusion imaging (CCTA + DE-CTP and CCTA + SPECT) for identifying coronary artery stenosis that causes myocardial hypoperfusion. Combined invasive coronary angiography (ICA) and stress perfusion cardiac magnetic resonance (SP-CMR) imaging are used as the reference standard. We retrospectively reviewed the records of 25 patients with suspected coronary artery disease, who underwent CCTA, DE-CTP, SPECT, SP-CMR, and ICA. The reference standard was defined as ≥ 50% stenosis by ICA, with a corresponding myocardial hypoperfusion on SP-CMR. For per-vascular territory analysis, the sensitivities of CCTA, DE-CTP, SPECT, CCTA + DE-CTP, and CCTA + SPECT were 96, 96, 68, 93, and 68%, respectively, and specificities were 72, 75, 89, 85, and 94%, respectively. The areas under the receiver operating characteristic curve (AUCs) were 0.84 ± 0.05, 0.85 ± 0.05, 0.79 ± 0.06, 0.89 ± 0.04, and 0.81 ± 0.06, respectively. For per-patient analysis, the sensitivities of CCTA, DE-CTP, SPECT, CCTA + DE-CTP, and CCTA + SPECT were 100, 100, 89, 100, and 83%, respectively; the specificities were 14, 43, 57, 43, and 57%, respectively; and the AUCs were 0.57 ± 0.13, 0.71 ± 0.11, 0.73 ± 0.11, 0.71 ± 0.11, and 0.70 ± 0.11, respectively. The combination of CCTA and DE-CTP enhances specificity without a loss of sensitivity for detecting hemodynamically significant coronary artery stenosis, as defined by combined ICA and SP-CMR.

  11. Perioperative outcomes in minimally invasive direct coronary artery bypass versus off-pump coronary artery bypass with sternotomy.

    Science.gov (United States)

    Tekin, Ali İhsan; Arslan, Ümit

    2017-09-01

    Surgical treatment of isolated left anterior descending coronary artery disease can be performed with either minimally invasive direct coronary artery bypass via a left anterior thoracotomy (MIDCAB) or off-pump coronary artery bypass via a median sternotomy (OPCAB). To compare the perioperative outcomes of patients undergoing MIDCAB or OPCAB surgery. Patients who underwent either MIDCAB or OPCAB for isolated left anterior descending (LAD) coronary artery disease between October 2013 and December 2015 were retrospectively evaluated. Operations were carried out by the same surgical team. Preoperative, intraoperative and postoperative data of the patients were recorded for analyses. Twenty-three patients (7 females, 16 males) underwent MIDCAB surgery, and 24 patients (4 female, 20 males) underwent OPCAB surgery. The two groups were comparable regarding preoperative patient characteristics. Duration of mechanical ventilation (5.1 ±0.7 h vs. 6.6 ±0.9 h), intensive care unit stay (19.4 ±2.5 h vs. 45.8 ±5.4 h) and hospital stay (4.3 ±0.4 days vs. 5.6 ±0.8 days) were significantly shorter in the MIDCAB group (p < 0.01). Patients in the OPCAB group required significantly more blood transfusions (1.83 ±0.38 units vs. 0.17 ±0.38 units) and fresh frozen plasma use (2.33 ±0.96 units vs. 0.69 ±0.76 units) (p < 0.01). Conversion to sternotomy was not required in the MIDCAB group. There was no mortality, conversion to cardiopulmonary bypass or serious complication in either group. We believe that the MIDCAB technique is more advantageous than the OPCAB technique in the treatment of patients with a critical LAD lesion.

  12. Current practice of transradial approach for coronary procedures: A survey by the Italian Society of Interventional Cardiology (SICI-GISE) and the Italian Radial Club

    International Nuclear Information System (INIS)

    Rigattieri, Stefano; Valsecchi, Orazio; Sciahbasi, Alessandro; Tomassini, Francesco; Limbruno, Ugo; Marchese, Alfredo; La Manna, Alessio; Mauro, Ciro; Varbella, Ferdinando; Berti, Segio; Tarantino, Fabio F.; Musumeci, Giuseppe

    2017-01-01

    Background: Transradial approach (TRA) for percutaneous coronary procedures is associated with improved patient outcome and is being increasingly adopted worldwide. We surveyed Italian interventional cardiologists in order to take a snapshot of the current practice of TRA. Methods: A web-based questionnaire was emailed to all members of the Italian Society of Interventional Cardiology. Results: The survey was taken by 508 respondents. Cardiogenic shock and chronic total occlusions represented the principal limitations to TRA. Right TRA was the default approach for 81% of respondents. Both diagnostic and interventional procedures were routinely performed through 6 Fr sheaths (83% and 93%, respectively); dedicated TRA curves were used in 11% of diagnostic and in about 3% of interventional procedures. Almost 70% of the operators did not assess dual hand circulation. In case of crossover, the contralateral radial artery was the preferred site (57%). Radial artery hemostasis was mostly achieved by pneumatic bracelet (64%) and patency of the radial artery during hemostasis was ensured in 60% of cases. Pre-discharge patency of the radial artery was routinely assessed by almost 60% of respondents. For diagnostic procedures, adequate heparin anticoagulation (5000 IU) was only given by 45% of operators. Most respondents believed that TRA is associated with greater radiation exposure for both the patient (82%) and the operator (98%) as compared to transfemoral approach. Conclusions: This survey provides contemporary data about the adoption of TRA in Italy and gives interesting insights about several technical and clinical issues related to the practice of this vascular approach for coronary procedures. - Highlights: • Transradial approach for coronary procedures is becoming increasingly popular. • We conducted a survey on the contemporary practice of transradial approach in Italy. • We appraised several clinical and technical issues related to transradial approach.

  13. Current practice of transradial approach for coronary procedures: A survey by the Italian Society of Interventional Cardiology (SICI-GISE) and the Italian Radial Club

    Energy Technology Data Exchange (ETDEWEB)

    Rigattieri, Stefano, E-mail: stefanorigattieri@yahoo.it [Interventional Cardiology Unit, Sandro Pertini Hospital, Roma (Italy); Valsecchi, Orazio [Cardiovascular Department, Papa Giovanni XXIII Hospital, Bergamo (Italy); Sciahbasi, Alessandro [Interventional Cardiology Unit, Sandro Pertini Hospital, Roma (Italy); Tomassini, Francesco [Cardiology Department, Ospedale degli Infermi, Rivoli (Italy); Limbruno, Ugo [Cardiology Unit, Azienda USL Toscana Sudest, Grosseto (Italy); Marchese, Alfredo [Interventional Cardiology Unit, Anthea Hospital, GVM Care & Research, Bari (Italy); La Manna, Alessio [Cardiovascular Department, Ferrarotto Hospital, University of Catania (Italy); Mauro, Ciro [Cardiovascular Department, Cardarelli Hospital, Napoli (Italy); Varbella, Ferdinando [Cardiology Department, Ospedale degli Infermi, Rivoli (Italy); Berti, Segio [Department of Cardiology, Fondazione Toscana “Gabriele Monasterio”, Ospedale del Cuore, Massa (Italy); Tarantino, Fabio F. [Cardiology Unit, Ospedale G.B. Morgagni-L. Pierantoni, Forlì (Italy); Musumeci, Giuseppe [Cardiovascular Department, Papa Giovanni XXIII Hospital, Bergamo (Italy)

    2017-04-15

    Background: Transradial approach (TRA) for percutaneous coronary procedures is associated with improved patient outcome and is being increasingly adopted worldwide. We surveyed Italian interventional cardiologists in order to take a snapshot of the current practice of TRA. Methods: A web-based questionnaire was emailed to all members of the Italian Society of Interventional Cardiology. Results: The survey was taken by 508 respondents. Cardiogenic shock and chronic total occlusions represented the principal limitations to TRA. Right TRA was the default approach for 81% of respondents. Both diagnostic and interventional procedures were routinely performed through 6 Fr sheaths (83% and 93%, respectively); dedicated TRA curves were used in 11% of diagnostic and in about 3% of interventional procedures. Almost 70% of the operators did not assess dual hand circulation. In case of crossover, the contralateral radial artery was the preferred site (57%). Radial artery hemostasis was mostly achieved by pneumatic bracelet (64%) and patency of the radial artery during hemostasis was ensured in 60% of cases. Pre-discharge patency of the radial artery was routinely assessed by almost 60% of respondents. For diagnostic procedures, adequate heparin anticoagulation (5000 IU) was only given by 45% of operators. Most respondents believed that TRA is associated with greater radiation exposure for both the patient (82%) and the operator (98%) as compared to transfemoral approach. Conclusions: This survey provides contemporary data about the adoption of TRA in Italy and gives interesting insights about several technical and clinical issues related to the practice of this vascular approach for coronary procedures. - Highlights: • Transradial approach for coronary procedures is becoming increasingly popular. • We conducted a survey on the contemporary practice of transradial approach in Italy. • We appraised several clinical and technical issues related to transradial approach.

  14. [Comparison of 64 MDCT coronary CTA and coronary angiography in the detection of coronary artery stenosis in low risk patients with stable angina and acute coronary syndrome].

    Science.gov (United States)

    Cazalas, G; Sarran, A; Amabile, N; Chaumoitre, K; Marciano-Chagnaud, S; Jacquier, A; Paganelli, F; Panuel, M

    2009-09-01

    To determine the accuracy of 64 MDCT coronary CTA (CCTA) compared to coronary angiography in low risk patients with stable angina and acute coronary syndrome and determine the number of significant coronary artery stenoses ( 50%) in these patients. Materials and methods. Fifty-five patients underwent CCTA using a 32 MDCT unit with z flying focus allowing the acquisition of 64 slices of 0.6 mm thickness as well as coronary angiography (gold standard). Nine patients were excluded due to prior coronary artery bypass surgery (n=4), insufficient breath hold (n=3), calcium scoring>1000 (n=1) and delay between both examinations over 4 months (n=1). Forty-six patients: 27 males and 19 females were included. CCTA results were compared to coronary angiography per segment and artery with threshold detection of stenoses 50%. The degree of correlation between both examinations was performed using a regression analysis with a Pearson correlation coefficient<0.05 considered significant. The overall accuracy of CCTA was 90%; limitations related to the presence of calcifications, motion artifacts or insufficient vessel opacification. The correlation for all analyzed segments was 96.4%. Thirty-eight of 50 significant stenoses seen on coronary angiography were correctly detected on CCTA. Sensitivity, specificity, PPVC and NPV for detection of stenoses 50% were 76%, 98.3%, 80.3% and 97.7% respectively. Evaluation per segment had a NPV of 96.8% (interventricular and diagonal segments) to 100% (main trunk). Our results for specificity and NPV are similar to reports from the literature. This suggests that CCTA in this clinical setting may replace coronary angiography.

  15. Impact of gender on outcome after coronary artery bypass surgery.

    Science.gov (United States)

    Ennker, Ina C; Albert, Alexander; Pietrowski, Detlef; Bauer, Kerstin; Ennker, Juergen; Florath, Ines

    2009-06-01

    Following recent studies concerning the increased risk of coronary artery bypass surgery for women, the impact of sex is still a controversial issue. Between 1996 and 2006, 9,527 men and 3,079 women underwent isolated coronary artery bypass in our institute. To adjust for dissimilarities in preoperative risk profiles, propensity score-based matching was applied. Before adjustment, clinical outcomes in terms of operative mortality, arrhythmias, intensive care unit stay, and maximum creatine kinase-MB levels were significantly different for men and women. After balancing the preoperative characteristics, including height, no significant differences in clinical outcomes were observed. However, there was decreased use of internal mammary artery, less total arterial revascularization, and increasing creatine kinase-MB levels with decreasing height. This study supports the theory that female sex per se does not increase operative risk, but shorter height, which is more common in women, affects the outcome, probably due to technical difficulties in shorter patients with smaller internal mammary arteries and coronary vessels. Thus women may especially benefit from sequential arterial grafting.

  16. A prototype for the PASS Permanent All Sky Survey

    Science.gov (United States)

    Deeg, H. J.; Alonso, R.; Belmonte, J. A.; Horne, K.; Alsubai, K.; Collier Cameron, A.; Doyle, L. R.

    2004-10-01

    A prototype system for the Permanent All Sky Survey (PASS) project is presented. PASS is a continuous photometric survey of the entire celestial sphere with a high temporal resolution. Its major objectives are the detection of all giant-planet transits (with periods up to some weeks) across stars up to mag 10.5, and to deliver continuously photometry that is useful for the study of any variable stars. The prototype is based on CCD cameras with short focal length optics on a fixed mount. A small dome to house it at Teide Observatory, Tenerife, is currently being constructed. A placement at the antarctic Dome C is also being considered. The prototype will be used for a feasibility study of PASS, to define the best observing strategies, and to perform a detailed characterization of the capabilities and scope of the survey. Afterwards, a first partial sky surveying will be started with it. That first survey may be able to detect transiting planets during its first few hundred hours of operation. It will also deliver a data set around which software modules dealing with the various scientific objectives of PASS will be developed. The PASS project is still in its early phase and teams interested in specific scientific objectives, in providing technical expertise, or in participating with own observations are invited to collaborate.

  17. Primary Percutaneous Coronary Intervention for ST elevation myocardial infarction complicated by Cardiogenic Shock

    International Nuclear Information System (INIS)

    Shaikh, A. H.; Hanif, B.; Pathan, A.; Khan, W.; Hashmani, S.; Raza, M.; Nasir, S.

    2013-01-01

    Objective: To determine the outcomes of primary percutaneous coronary intervention for ST elevation myocardial infarction complicated by cardiogenic shock. Methods: The retrospective study was conducted at the Tabba Heart Institute, a private-sector facility in Karachi. It reviewed the medical records of 56 consecutive patients between January 2009 and June 2011 with acute ST elevation myocardial infarction complicated by cardiogenic shock and subjected to primary percutaneous coronary intervention. The primary end point was in-hospital mortality and its predictors. SPSS 14 was used for statistical analysis. Results: The mean age of the study patients was 63+-11.7 years; 38 (68%) were male; 32 (57%) were hypertensive; and 39 (69%) were diabetic. Most infarcts were anterior in location (n=36; 64%). Besides, 33 (59%) required ventilatory support. Intra-aortic balloon pump was placed in 30 (54%), and 33 (59%) patients had multivessel coronary artery disease. In-hospital mortality occurred in 26 (46%). Multivariate logistic regression analysis showed that age >60 years (p= 0.05), diabetes (p <0.01) and left ventricular ejection fraction <40% (p= 0.01) were independent predictors of in-hospital mortality. Conclusions: Results emphasise the need of aggressive management of patients with cardiogenic shock utilising primary percutaneous coronary intervention as a reperfusion strategy to improve clinical outcomes. (author)

  18. THE PLURAL LESION CORONARY AND CYTOKINES DISBALANCE IN PATIENTS WITH CORONARY ATHEROSCLEROSIS

    Directory of Open Access Journals (Sweden)

    Martynov AV

    2012-12-01

    Full Text Available The aim of the study was to examine the levels of the main pro-inflammatory and anti-inflammatory cytokines in patients with ischemic heart disease, and the study of the possible impact of persistent herpes virus infection plural lesion coronary arteries. A total of 57 patients (mean age 49,3 ± 3,7 years IHD s hemodynamically significant stenoses of the coronary vessels. Conducted virological examination, including the definition of hypertension HSV1, HSV2, HHV6, SMV, VZV and VEB immunofluorescent and cytokines ІL-1β, ІL-6 ІL-8, TNF by ELISA in serum. Found increased levels of proinflammatory cytokines ІL-1β, ІL-6 and FNPα of IHD patients who had hemodynamically significant stenoses of coronary vessels. ІL-6 level in patients with 2 or more significant coronary artery lesions exceeded the rate of patients with a damaged coronary artery in 1.67 TNFα, ІL-8 - 1.37 ІL-1β and 1.28 times respectively. In patients with plural coronary vascular damage was the most common combination of CMV, VEB and HHV6. Since CMV was detected in more than 60% of patients with injuries of two spacecraft and nearly 76% from three spacecraft, VEB was detected in 72% and 88%, respectively.

  19. Multi-slice spiral CT of the coronary arteries: improved vessel presentation by means of a standard software

    International Nuclear Information System (INIS)

    Schmitt, R.; Froehner, S.; Coblenz, G.; Christopoulos, G.; Brunn, J.; Mueller, M.; Kerber, S.; Fellner, F.

    2001-01-01

    Material and methods: Image data of 151 patients suffering from coronary artery disease were calculated by means of retrospective triggering at four different diastolic delay times in contrast-enhanced CT. The large coronary segments were subsequently reconstructed in two planes with multiplanar volume reconstruction (MPVR). Results: On the pre-condition that data sets were acquired at sinus rhythm and at a heart beat rate lower than 65/min coronary arteries could be depicted over a long distance in single or double angulated reconstruction planes with the help of MPVR. Time consumption for image reconstruction was reasonable. Additionally to the anatomy of the coronary arteries in two different planes, typical CT findings in occluding coronary artery disease are presented. (orig.) [de

  20. Management of cardiac arrest caused by coronary artery spasm: epinephrine/adrenaline versus nitrates.

    Science.gov (United States)

    Kiss, Gabor; Corre, Olivier; Gueret, Gildas; Nguyen Ba, Vinh; Gilard, Martine; Boschat, Jaques; Arvieux, Charles Chistian

    2009-01-01

    Cardiopulmonary resuscitation guidelines imply the use of epinephrine/adrenaline during cardiopulmonary arrest. However, in cardiac arrest situations resulting from coronary artery spasm (CAS), the use of epinephrine/adrenaline could be deleterious. A 49-year-old patient underwent an emergency coronarography with an attempt to stent the coronary arteries. Radiologic imaging revealed a positive methylergonovine maleate (Methergine, Novartis Pharmaceuticals, East Hanover, NJ) test, with subocclusive CAS in several coronary vessels leading to electromechanical dissociation. Cardiopulmonary resuscitation was performed, and intracoronary boluses of isosorbide dinitrate were given to treat CAS. Epinephrine/adrenaline was not administered during resuscitation. Spontaneous circulation was obtained after cardioversion for ventricular fibrillation, and the patient progressively regained consciousness. Resuscitation guidelines do not specify the use of trinitrate derivatives in cardiac arrest situations caused by CAS. The pros and cons of the use of nitrates and epinephrine/adrenaline during cardiac arrest caused by CAS are analyzed in this case report.

  1. Belief propagation decoding of quantum channels by passing quantum messages

    International Nuclear Information System (INIS)

    Renes, Joseph M

    2017-01-01

    The belief propagation (BP) algorithm is a powerful tool in a wide range of disciplines from statistical physics to machine learning to computational biology, and is ubiquitous in decoding classical error-correcting codes. The algorithm works by passing messages between nodes of the factor graph associated with the code and enables efficient decoding of the channel, in some cases even up to the Shannon capacity. Here we construct the first BP algorithm which passes quantum messages on the factor graph and is capable of decoding the classical–quantum channel with pure state outputs. This gives explicit decoding circuits whose number of gates is quadratic in the code length. We also show that this decoder can be modified to work with polar codes for the pure state channel and as part of a decoder for transmitting quantum information over the amplitude damping channel. These represent the first explicit capacity-achieving decoders for non-Pauli channels. (fast track communication)

  2. Belief propagation decoding of quantum channels by passing quantum messages

    Science.gov (United States)

    Renes, Joseph M.

    2017-07-01

    The belief propagation (BP) algorithm is a powerful tool in a wide range of disciplines from statistical physics to machine learning to computational biology, and is ubiquitous in decoding classical error-correcting codes. The algorithm works by passing messages between nodes of the factor graph associated with the code and enables efficient decoding of the channel, in some cases even up to the Shannon capacity. Here we construct the first BP algorithm which passes quantum messages on the factor graph and is capable of decoding the classical-quantum channel with pure state outputs. This gives explicit decoding circuits whose number of gates is quadratic in the code length. We also show that this decoder can be modified to work with polar codes for the pure state channel and as part of a decoder for transmitting quantum information over the amplitude damping channel. These represent the first explicit capacity-achieving decoders for non-Pauli channels.

  3. Increased epicardial fat volume quantified by 64-multidetector computed tomography is associated with coronary atherosclerosis and totally occlusive lesions

    International Nuclear Information System (INIS)

    Ueno, Koji; Anzai, Toshihisa; Jinzaki, Masahiro

    2009-01-01

    The relationship between the epicardial fat volume measured by 64-slice multidetector computed tomography (MDCT) and the extension and severity of coronary atherosclerosis was investigated. Both MDCT and conventional coronary angiography (CAG) were performed in 71 consecutive patients who presented with effort angina. The volume of epicardial adipose tissue (EAT) was measured by MDCT. The severity of coronary atherosclerosis was assessed by evaluating the extension of coronary plaques in 790 segments using MDCT data, and the percentage diameter stenosis in 995 segments using CAG data. The estimated volume of EAT indexed by body surface area was defined as VEAT. Increased VEAT was associated with advanced age, male sex, degree of metabolic alterations, a history of acute coronary syndrome (ACS) and the presence of total occlusions, and showed positive correlation with the stenosis score r=0.28, P=0.02) and the atheromatosis score (r=0.67, P 3 /m 2 ) to be the strongest independent determinant of the presence of total occlusions odds ratio 4.64. P=0.02). VEAT correlates with the degree of metabolic alterations and coronary atheromatosis. Excessive accumulation of EAT might contribute to the development of ACS and coronary total occlusions. (author)

  4. Myocardial damage in successful vessel coronary angioplasty as assessed by creatinine kinase and its myocardium band isoenzyme levels

    International Nuclear Information System (INIS)

    Abbas, S.; Samor, N.A.; Kayani, A.M.

    2008-01-01

    To determine the frequency of myocardial damage in elective, successful, single vessel percutaneous coronary angioplasty by assessing myocardial band (MB), creatinine kinase levels and to find out the association of common modifiable risk factors with myocardial damage in patients undergoing single vessel coronary angioplasty. Fifty patients undergoing elective and successful single vessel percutaneous coronary angioplasty were evaluated with creatinine kinase and creatinine kinase MB levels before and after 8 hours and 1st day following coronary angioplasty. Studied variables included the length of stent deployed, maximum deployment pressure and total balloon inflation time, apart from hypertension, cholesterol level, smoking and diabetes mellitus. Out of 50 patients, 9 had raised creatinine kinase at 8 hours (18%) and 10 had raised creatinine kinase (20%) on 1st day following coronary angioplasty, 7 (14%) patients and 8 (16%) patients had raised creatinine kinase MB levels at 8 hours and 1st day following coronary angioplasty respectively. The rise of either was equal to or more than 3 times the normal limits. Modifiable risk factors, significantly associated with myocardial damage, were diabetes mellitus (p=0.006) and LDL levels (p=0.009) in patients undergoing single vessel coronary angioplasty. Successful elective, uncomplicated, single vessel coronary angioplasty resulted in some myocardial damage evident by mild rise in cardiac enzymes but rise of creatinine kinase MB above 3 times of normal, which signifies percutaneous coronary angioplasty-related myocardial infarction, was not seen. There was a significant association between diabetes mellitus, LDL levels and myocardial damage in patients undergoing coronary angioplasty but no significant association was found between hypertension, smoking and myocardial damage. (author)

  5. Frequency and importance of radiologically visible coronary scleroses

    International Nuclear Information System (INIS)

    Hoyer, B.

    1981-01-01

    The importance of radiologically visible coronary sceleroses for an early diagnosing of coronary heart disease was investigated. In 3 mixed collectives of patients with and without coronary heart diseases who had had a coronary angiography were examined retrospectively for coronary sclerosis (group I: standard films, group II: old X-ray findings, group III: fluoroscopy before beginning coronary angiography). In the retrospective evaluation, the sensitivity to the recognition of coronary heart disease was low. With prospective examination by means of fluoroscopy, coronary calcification could be proven in 37.66% of the patients with coronary diseases (sensitivity); the specificity (no coronary calcification in persons without coronary disease) was 99%. The duration and extent of a calcification do not show a definite influence on the severity of the disease. Several coronary scleroses in one or several vessels mostly indicate a vascular disease. Coronary scleroses are not necessarily located in the same point as coronary stenoses: in 85.5% of the patients with coronary sclerosis of the left truncus, haemodynamically important stenoses were found only in following vascular regions. Considering the high specificity of coronary scleroses in the fluoroscopic picture and the high sensitivity under favourable conditions, this method seems to be suitable as a screening method for early recognition of coronary heart diseases in the asymptomatic stage. A proven coronary sclerosis should in any case be the cause for continuing the search for a coronary heart disease. The radiation exposure during fluoroscopy of coronary sclerosis is low if the adjustment is correct, it takes little time, the patient is not put to discomfort. (orig./MG) [de

  6. Experimental study of boundary-layer transition on an airfoil induced by periodically passing wake

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, W.P. [Center for Turbulence and Flow Control Research Institute of Advanced Machinery and Design, Seoul National University (Korea); Park, T.C.; Kang, S.H. [School of Mechanical and Aerospace Engineering, Seoul National University (Korea)

    2002-02-01

    Hot-wire measurements are performed in boundary-layer flows developing on a NACA 0012 airfoil over which wakes pass periodically. The periodic wakes are generated by rotating circular cylinders clockwise or counterclockwise around the airfoil. The time- and phase-averaged mean streamwise velocities and turbulence fluctuations are measured to investigate the phenomena of wake-induced transition. Especially, the phase-averaged wall shear stresses are evaluated using a computational Preston tube method. The passing wakes significantly change the pressure distribution on the airfoil, which has influence on the transition process of the boundary layer. The orientation of the passing wake alters the pressure distribution in a different manner. Due to the passing wake, the turbulent patches are generated inside the laminar boundary layer on the airfoil, and the boundary layer becomes temporarily transitional. The patches propagate downstream at a speed smaller than the free-stream velocity and merge together further downstream. Relatively high values of phase-averaged turbulence fluctuations in the outer part of the boundary layer indicate the possibility that breakdown occurs in the outer layer away from the wall. It is confirmed that the phase-averaged mean velocity profile has two dips in the outer region of the transitional boundary layer for each passing cycle. (orig.)

  7. Coronary plaque morphology on multi-modality imagining and periprocedural myocardial infarction after percutaneous coronary intervention

    Directory of Open Access Journals (Sweden)

    Akira Sato

    2016-06-01

    Full Text Available Percutaneous coronary intervention (PCI may be complicated by periprocedural myocardial infarction (PMI as manifested by elevated cardiac biomarkers such as creatine kinase (CK-MB or troponin T. The occurrence of PMI has been shown to be associated with worse short- and long-term clinical outcome. However, recent studies suggest that PMI defined by biomarker levels alone is a marker of atherosclerosis burden and procedural complexity but in most cases does not have independent prognostic significance. Diagnostic multi-modality imaging such as intravascular ultrasound, optical coherence tomography, coronary angioscopy, near-infrared spectroscopy, multidetector computed tomography, and magnetic resonance imaging can be used to closely investigate the atherosclerotic lesion in order to detect morphological markers of unstable and vulnerable plaques in the patients undergoing PCI. With the improvement of technical aspects of multimodality coronary imaging, clinical practice and research are increasingly shifting toward defining the clinical implication of plaque morphology and patients outcomes. There were numerous published data regarding the relationship between pre-PCI lesion subsets on multi-modality imaging and post-PCI biomarker levels. In this review, we discuss the relationship between coronary plaque morphology estimated by invasive or noninvasive coronary imaging and the occurrence of PMI. Furthermore, this review underlies that the value of the multimodality coronary imaging approach will become the gold standard for invasive or noninvasive prediction of PMI in clinical practice.

  8. Development and characterization of a coronary polylactic acid stent prototype generated by selective laser melting.

    Science.gov (United States)

    Flege, Christian; Vogt, Felix; Höges, Simon; Jauer, Lucas; Borinski, Mauricio; Schulte, Vera A; Hoffmann, Rainer; Poprawe, Reinhart; Meiners, Wilhelm; Jobmann, Monika; Wissenbach, Konrad; Blindt, Rüdiger

    2013-01-01

    In-stent restenosis is still an important issue and stent thrombosis is an unresolved risk after coronary intervention. Biodegradable stents would provide initial scaffolding of the stenosed segment and disappear subsequently. The additive manufacturing technology Selective Laser Melting (SLM) enables rapid, parallel, and raw material saving generation of complex 3- dimensional structures with extensive geometric freedom and is currently in use in orthopedic or dental applications. Here, SLM process parameters were adapted for poly-L-lactid acid (PLLA) and PLLA-co-poly-ε-caprolactone (PCL) powders to generate degradable coronary stent prototypes. Biocompatibility of both polymers was evidenced by assessment of cell morphology and of metabolic and adhesive activity at direct and indirect contact with human coronary artery smooth muscle cells, umbilical vein endothelial cells, and endothelial progenitor cells. γ-sterilization was demonstrated to guarantee safety of SLM-processed parts. From PLLA and PCL, stent prototypes were successfully generated and post-processing by spray- and dip-coating proved to thoroughly smoothen stent surfaces. In conclusion, for the first time, biodegradable polymers and the SLM technique were combined for the manufacturing of customized biodegradable coronary artery stent prototypes. SLM is advocated for the development of biodegradable coronary PLLA and PCL stents, potentially optimized for future bifurcation applications.

  9. Cardiac symptoms before sudden cardiac death caused by coronary artery disease

    DEFF Research Database (Denmark)

    Jabbari, Reza; Risgaard, Bjarke; Holst, Anders G

    2013-01-01

    The aim of this nationwide case-control study was to identify and characterise symptoms before sudden death of young persons who had died due to coronary artery disease (CAD).......The aim of this nationwide case-control study was to identify and characterise symptoms before sudden death of young persons who had died due to coronary artery disease (CAD)....

  10. A Two-Pass Exact Algorithm for Selection on Parallel Disk Systems.

    Science.gov (United States)

    Mi, Tian; Rajasekaran, Sanguthevar

    2013-07-01

    Numerous OLAP queries process selection operations of "top N", median, "top 5%", in data warehousing applications. Selection is a well-studied problem that has numerous applications in the management of data and databases since, typically, any complex data query can be reduced to a series of basic operations such as sorting and selection. The parallel selection has also become an important fundamental operation, especially after parallel databases were introduced. In this paper, we present a deterministic algorithm Recursive Sampling Selection (RSS) to solve the exact out-of-core selection problem, which we show needs no more than (2 + ε ) passes ( ε being a very small fraction). We have compared our RSS algorithm with two other algorithms in the literature, namely, the Deterministic Sampling Selection and QuickSelect on the Parallel Disks Systems. Our analysis shows that DSS is a (2 + ε )-pass algorithm when the total number of input elements N is a polynomial in the memory size M (i.e., N = M c for some constant c ). While, our proposed algorithm RSS runs in (2 + ε ) passes without any assumptions. Experimental results indicate that both RSS and DSS outperform QuickSelect on the Parallel Disks Systems. Especially, the proposed algorithm RSS is more scalable and robust to handle big data when the input size is far greater than the core memory size, including the case of N ≫ M c .

  11. Acute Thrombotic Coronary Occlusion in a Patient with Coronary Artery Anomaly

    Directory of Open Access Journals (Sweden)

    Beganu Elena

    2017-09-01

    Full Text Available Patients with coronary artery anomalies are more susceptible to develop acute thrombotic coronary occlusions due to the abnormal anatomy of these arteries and the disturbance of the pathophysiological mechanisms that lead to an accelerated atherosclerosis development. The following article presents the case of a 64-year-old female patient diagnosed with anterior ST-segment elevation myocardial infarction. The patient underwent primary percutaneous coronary intervention, which revealed the absence of the right coronary artery and separated origins of the left anterior descending artery and the left circumflex artery from the aorta.

  12. FORMATION OF SIX SIGMA INFRASTRUCTURE FOR THE CORONARY STENTING PROCESS

    Directory of Open Access Journals (Sweden)

    Mehmet Tolga Taner

    2013-10-01

    Full Text Available The purpose of this study is to show how a tertiary care center in Turkey operating mainly in cardiology initiated Six Sigma principles to reduce the number of complications occuring during coronary stent insertion process. A Six Sigma’s Define-Measure-Analyze-Improve-Control (DMAIC model for coronary stent insertion is suggested. Data were collected for 24-months. Twenty-two Critical-to-Quality (CTQ factors were identified for successful coronary stent insertion. The most frequent causes of complications in the process were found to be patients with previous bypass surgery or PCI, inexperience of staff members, highly damaged vessel structure, thin and/or long vessel diameter, inappropriate selection of stent type, inappropriate selection of balloon type and poor image quality.

  13. Evaluation of right coronary anomalous origin with mulpi-slice spiral CT

    International Nuclear Information System (INIS)

    Shi Heshui; Han Ping; Kong Xiangquan; Feng Hansheng; Brambs, H.-J.; Hoffmann, M.H.K.

    2006-01-01

    Objective: To evaluate the role of 16-slice spiral computed tomography angiography (MSCTA) to identify the anomalous origin and anatomic course of the right coronary artery (RCA) with conventional X-ray coronary angiography (CAG) serving as standard of reference. Methods: MSCTA data in 8 patients with anomalous RCA were retrospectively analyzed for the study, 7 of them had also undergone CAG examinations. MSCTA and CAG images were analyzed in blinded fashion for accuracy of anomalous artery origin and path detection. Results were compared in a secondary consensus evaluation. Virtual endoscopy (VE) was used to evaluate the orifice of the anomalous arteries and its relationship with the adjacent ostia of normal arteries. Multi-planar reconstruction (MPR), curved MPR, thin-slab maximum intensity projection (MIP), volume rendering (VR) or slab VR (cut-plane VR) were used to assess the aberrant path of the RCA and its relationship with the adjacent large vessels. At least two views of the RCA were analyzed on CAG. Results: The anomalous RCA for all 8 patients were correctly displayed on MSCTA. RCA originated from the left sinus of Valsalva in 6 patients, one RCA from the end of left main coronary artery, another RCA arose from the posterior sinus of Valsalva. The anomalous ostia showed no stenosis. All of them passed between the aortic root and the pulmonary artery. For 7 patients with CAG alone correct identification of the abnormality was achieved in only 71%. Conclusion: MSCTA was superior to show the anomalous orifice and path of the RCA, it should be considered as a prime non-invasive imaging tool for suspected coronary anomalies. (authors)

  14. High-resolution imaging of coronary calcifications by intense low-energy fluoroscopic X-ray obtained from synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Ohtsuka, S.; Sugishita, Y.; Takeda, T.; Itai, Y.; Tada, J.; Hyodo, K.; Ando, M. [Inst. of Clinical Medicine, Univ. of Tsukuba, Ibaraki (Japan). Dept. of Cardiology

    2000-07-01

    In order to obtain an intense monochromatic low-energy X-ray from synchrotron radiation (SR) and apply it to detect coronary calcifications, the SR beam was reflected with a silicon crystal to be expanded (150 mm in height and 80 mm in width) and to be monochromatized at an energy level of 37 keV. The X-ray was intermittently irradiated to obtain dynamic imaging of 30 images/s. Images were recorded by a digital fluorography system. The low-energy X-ray from SR sharply visualized calcification of coronary arteries, while conventional X-ray could not visualize coronary calcification. The intense monochromatic low-energy X-ray from SR is sensitive, has high-resolution for imaging coronary calcification and may serve as a screening method for coronary artery disease.

  15. Acute occlusion of the coronary artery after transluminal balloon coronary angioplasty

    International Nuclear Information System (INIS)

    Savchenko, A.P.; Matchin, Yu.G.; Lyakishev, A.A.

    1995-01-01

    The research was aimed at elucidation of the relationship of the clinical and angiographic factors, on the one hand, and development of acute occlusion following transluminal balloon coronary angioplasty TBCA, on the other. TBCA was carried out in 162 patients. Eight (4.9 %) patients developed acute occlusion of the coronary artery, which was complicated by acute myocardial infarction in 50 % cases. 35 refs.; 4 tabs

  16. Multiple Culprit Coronary Artery Thrombosis in a Patient with Coronary Ectasia

    Directory of Open Access Journals (Sweden)

    Bruno da Silva Matte

    2018-01-01

    Full Text Available We here report a case of ST-elevation myocardial infarction (STEMI due to simultaneous acute coronary artery occlusions of two major coronary arteries in a patient with coronary ectasia. The patient had been previously submitted to percutaneous coronary angioplasty with bare metal stent implantation in both culprit vessels. Very late stent thrombosis could be the cause of the first occlusion, triggering the event in the other vessel. In addition, concomitant embolic sources were not identified. Although routine aspiration thrombectomy in STEMI was not proven to be beneficial in randomized clinical trials, it was of great value in this case. We also discuss the relation between coronary ectasia, chronic inflammatory status, and increased platelet activity which may have caused plaque disruption in another already vulnerable vessel.

  17. Repair of anomalous aortic origin of a coronary artery in 113 patients: a Congenital Heart Surgeons' Society report.

    Science.gov (United States)

    Poynter, Jeffrey A; Bondarenko, Igor; Austin, Erle H; DeCampli, William M; Jacobs, Jeffrey P; Ziemer, Gerhard; Kirshbom, Paul M; Tchervenkov, Christo I; Karamlou, Tara; Blackstone, Eugene H; Walters, Henry L; Gaynor, J William; Mery, Carlos M; Pearl, Jeffrey M; Brothers, Julie A; Caldarone, Christopher A; Williams, William G; Jacobs, Marshall L; Mavroudis, Constantine

    2014-10-01

    Anomalous aortic origin of a coronary artery (AAOCA) encompasses a wide morphologic spectrum, which has impeded consensus regarding indications for the diverse repair strategies. We constructed a profile of current surgical techniques and explore their application to morphologic variants. Patients<30 years old (n=113) with isolated AAOCA who underwent operations at 29 Congenital Heart Surgeons Society (CHSS) institutions from 1998 to 2012 were identified from the CHSS AAOCA Registry. Operative findings were related to surgical techniques at index repairs by cross-tabulation. Anomalous origin of the left main or left anterior descending coronary artery was present in 33 (29%) patients and of the right coronary artery in 78 (69%) patients; 2 arteries originated directly above the commissure between the left and right sinuses. There were 101 (89%) interarterial and intramural (IA/IM) arteries, 10 (9%) were interarterial but not intramural (IA/NIM) and 2 (2%) were neither interarterial nor intramural. Intramural arteries were unroofed in 100 (88%) operations, usually with intimal tacking after incision (n=47) or excision (n=25) of the common wall. Coronary reimplantation (n=11), pulmonary artery relocation (n=7; 5 for IA/NIM), simple ostioplasty (without unroofing; n=3), coronary artery bypass grafting (n=2), and ostial window (n=1) were less common. In 37 (33%) operations, a valvar commissure was taken down; 33 were resuspended. Current surgical repair of AAOCA is individualized to morphology, particularly the presence of intramural and/or interarterial segments. This report is foundational for future planned CHSS studies that will examine interventional and noninterventional outcomes and ultimately guide management of AAOCA. © The Author(s) 2014.

  18. Evaluation of the early enhancement of coronary atherosclerotic plaque by contrast-enhanced MR angiography

    Energy Technology Data Exchange (ETDEWEB)

    Li Tao [Department of Radiology, The General Hospital of Chinese People' s Armed Police Forces, Number 69, Yong Ding Road, Hai Dian District, Beijing (China); Department of Radiology, Chinese People' s Liberation Army General Hospital, Number 28, Fu Xing Road, Hai Dian District, Beijing (China); Zhao Xihai [Department of Radiology, Chinese People' s Liberation Army General Hospital, Number 28, Fu Xing Road, Hai Dian District, Beijing (China); Liu Xin [Paul C. Lauterbur Biomedical Imaging Center, Institute of Biomedical and Health Engineering, Shenzhen Institute of Advanced Technology, Chinese Academy of Science, Shenzhen 518067 (China); Gao Jianhua [Department of Radiology, The General Hospital of Chinese People' s Armed Police Forces, Number 69, Yong Ding Road, Hai Dian District, Beijing (China); Zhao Shaohong [Department of Radiology, Chinese People' s Liberation Army General Hospital, Number 28, Fu Xing Road, Hai Dian District, Beijing (China); Li Xin; Zhou Weihua [Department of Radiology, The General Hospital of Chinese People' s Armed Police Forces, Number 69, Yong Ding Road, Hai Dian District, Beijing (China); Cai Zulong [Department of Radiology, Chinese People' s Liberation Army General Hospital, Number 28, Fu Xing Road, Hai Dian District, Beijing (China); Zhang Weiguo [Cardiovascular and Neurological Consulting Institute, 6771 San Fernando, Irving, TX 75039 (United States); Yang Li, E-mail: Yangli301@yahoo.com [Department of Radiology, Chinese People' s Liberation Army General Hospital, Number 28, Fu Xing Road, Hai Dian District, Beijing (China)

    2011-10-15

    Purpose: To evaluate the early enhancement of coronary atherosclerotic plaque using contrast-enhanced MR angiography (CE-MRA) and investigate the association between unstable angina pectoris (UAP) and early enhancement of the plaque. Methods: Forty-one patients presenting with angina pectoris and demonstrating single-vessel disease with non-calcified plaque and significant coronary stenosis ({>=}50%) on CTA were consecutively recruited for coronary CE-MRA. Contrast-to-noise ratio of the culprit plaque guided by CTA was measured on a cross-sectional multi-planar reconstruction image of the plaque on both pre- and post-CE-MRA. A 50% increasing of CNR was defined as plaque enhancement. The association between early enhancement of the plaques and UAP was analyzed. Results: Thirty-seven non-calcified plaques with significant coronary stenosis were detected in the 37 patients on MRA. 4 subjects were excluded because coronary atherosclerotic plaques were inadequate for identification on MRA. Of the 37 patients, 18 patients had UAP and other 19 patients presented stable angina pectoris (SAP). Of the 37 plaques on CE-MRA, 13 and 24 plaques presented early enhancement and no enhancement, respectively. Of the 13 early-enhanced plaques, 11 (85%) and 2 (15%) were found in the patients with UAP and SAP, respectively (p < 0.01). Of the 37 patients, 11 (61%) with UAP and 2 (11%) with SAP had early-enhanced plaques, respectively (p < 0.01). Conclusion: CE-MRA allows detection of early enhancement of coronary atherosclerotic plaque. The early enhancement is common in unstable angina and could be a sign of vulnerability.

  19. TPG bus passes

    CERN Multimedia

    Staff Association

    2013-01-01

    The CERN Staff Association will stop selling TPG bus passes. All active and retired members of the CERN personnel will be able to purchase Unireso bus passes from the CERN Hostel - Building 39 (Meyrin site) from 1st February 2013. For more information: https://cds.cern.ch/journal/CERNBulletin/2013/04/Announcements/1505279?ln=en

  20. Real-time digital signal recovery for a multi-pole low-pass transfer function system.

    Science.gov (United States)

    Lee, Jhinhwan

    2017-08-01

    In order to solve the problems of waveform distortion and signal delay by many physical and electrical systems with multi-pole linear low-pass transfer characteristics, a simple digital-signal-processing (DSP)-based method of real-time recovery of the original source waveform from the distorted output waveform is proposed. A mathematical analysis on the convolution kernel representation of the single-pole low-pass transfer function shows that the original source waveform can be accurately recovered in real time using a particular moving average algorithm applied on the input stream of the distorted waveform, which can also significantly reduce the overall delay time constant. This method is generalized for multi-pole low-pass systems and has noise characteristics of the inverse of the low-pass filter characteristics. This method can be applied to most sensors and amplifiers operating close to their frequency response limits to improve the overall performance of data acquisition systems and digital feedback control systems.

  1. The relationship between coronary artery calcification detected by non-gated multi-detector CT in patients with suspected ischemic heart disease and myocardial ischemia detected by thallium exercise stress testing

    International Nuclear Information System (INIS)

    Nishida, Chikako; Okajima, Kaoru; Yamamoto, Takashi; Hattori, Ryuichi; Kudo, Takashi; Nishimura, Yasumasa

    2005-01-01

    The objective of this study was to examine whether we could predict myocardial ischemia when coronary artery calcification is detected by non-gated multidetector CT in patients with suspected ischemic heart disease. Eighty-three patients suspected of having ischemic heart disease (55 men, 28 women; age range 36-83 years; mean age 68 years) underwent multidetector CT and Tl-201 single photon emission computed tomography. Prediction of myocardial ischemia by coronary arterial calcification detected on CT was evaluated by comparing the coronary artery territories that showed calcification with the area of myocardial ischemia determined by SPECT. The sensitivity, specificity, positive predictive value, and negative predictive value of multidetector CT for predicting myocardial ischemia were calculated. Coronary angiography was also examined and compared with multidetector CT. Risk factors, including hypertension, smoking, hyperlipidemia, diabetes, and family history, were compared for evidence of coronary artery calcification detected by multidetector CT and myocardial ischemia detected by thallium nuclear scans. For analysis by patients, the sensitivity, specificity, positive predictive value, and negative predictive value of coronary artery calcification for myocardial ischemia detection were 65, 63, 56, and 71%, respectively. Similarly, for analysis by coronary arterial territories, those values were 56, 77, 41 and 86%, respectively. Coronary stenosis on CAG was also related to the ischemia determined by SPECT and calcification on multidetector CT. Ischemia was better influenced by risk factors than was coronary arterial calcification. For analysis by coronary arterial territories, the specificity and negative predictive value of coronary arterial calcification seen by multidetector CT are relatively high. (author)

  2. Three-Dimensional Respiratory-Gated Coronary Mr Angiography with Reference to X-Ray Coronary Angiography

    International Nuclear Information System (INIS)

    Ikonen, A. E. J.; Manninen, H. I.; Vainio, P.; Vanninen, R. L.; Matsi, P. J.; Soimakallio, S.; Hirvonen, T.P.J.; Hartikainen, J.E.K.

    2003-01-01

    Purpose: To assess the clinical value of three-dimensional coronary MR angiography (CMRA) in the detection of significant coronary artery stenosis using conventional X-ray angiography as the standard reference. Material and Methods: Sixty-nine patients underwent X-ray coronary angiography and CMRA because of suspected or previously diagnosed coronary artery disease. MRI was performed with a 1.5-T whole body imaging system using ECG-triggered 3D gradient echo sequence with retrospective navigator echo respiratory gating and fat suppression. Results: A total of 276 coronary artery segments were analyzed. The X-ray coronary angiography was normal in 22 patients. Significant proximal stenoses (exceeding 50%) or occlusions were present in 102 coronary artery segments. In all, 120 stenoses or occlusions were identified in CMRA. Sixteen percent of the coronary artery segments had to be excluded because of poor image quality. The overall sensitivity and specificity for MRA for identification of significant stenosis were 75% and 62%, respectively. CMRA correctly detected 89% of patients with at least one vessel disease, but 6 patients with coronary artery disease would have been missed. Conclusions: Because of the high data exclusion and false-negative case rate, CMRA with retrospective navigator echo triggering is at present not suitable as a clinical screening method in coronary artery disease

  3. Coronary artery anomalies in adults: imaging at dual source CT coronary angiography

    International Nuclear Information System (INIS)

    Laspas, Fotios; Roussakis, Arkadios; Mourmouris, Christos; Kritikos, Nikolaos; Efthimiadou, Roxani; Andreou, John

    2013-01-01

    Congenital abnormalities of the coronary arteries have an incidence of 1%, and most of these are benign. However, a small number are associated with myocardial ischaemia and sudden death. Various imaging modalities are available for coronary artery assessment. Recently, multi-detector CT has emerged as an accurate diagnostic tool for defining coronary artery anomalies. The purpose of this pictorial essay is to review the dual source CT appearance of congenital anomalies of the coronary arteries in adults.

  4. Prevalence of Atherosclerotic Coronary Stenosis in Asymptomatic North Indian Population: A Post-mortem Coronary Angiography Study.

    Science.gov (United States)

    Bansal, Yogender Singh; Mandal, Shatrugan Prasad; Kumar, Senthil; Setia, Puneet

    2015-09-01

    A preliminary study of coronaries using post-mortem angiography was undertaken to see the prevalence of atherosclerotic coronary stenosis in non-cardiac unnatural deaths. This study was conducted in a tertiary care centre located in Chandigarh. A total of 128 medico-legal cases were studied comprising 88 males and 40 females. Post-mortem examinations of these MLC cases were conducted in the Department of Forensic Medicine, PGIMER, Chandigarh. All hearts were visually screened by post-mortem coronary angiography first and then grossly examined using serial transverse incision technique in positive screening cases to find the degree of narrowing. Of the study group, 34% males and 20% females showed evidence of narrowing on angiography. Of the males showing coronary stenosis, 83% had single vessel disease and 13% had double vessel disease, while only one individual had triple vessel disease. In cases of female, all the cases of coronary stenosis were single vessel disease. Left anterior descending coronary artery (LAD) was the most common vessel involved, followed by right coronary artery (RCA) & Left circumflex artery (LCX) and in cases of double vessel disease, LAD in combination with LCX was responsible for 75% of the cases. Remarkably 23.6% of study population in the age group of less than 40 years showed appreciable narrowing in at least one of the coronaries. In general, the prevalence of CAD is on the rise, particularly in younger population owing to the changes in their lifestyle and food habits. This preliminary study revealed evidence of narrowing of at least one coronary in 34% male and 20% female population and 23.6% subjects were less than 40 years old. Further detailed studies are needed especially in younger age group and to support the need for preventive cardiology in the early years of life.

  5. A comparison of directional atherectomy with coronary angioplasty in patients with coronary artery disease

    NARCIS (Netherlands)

    E.J. Topol (Eric); F. Leya; C.A. Pinkerton; P.L. Whitlow (Patrick); B. Hofling; C.A. Simonton; R.R. Masden; P.W.J.C. Serruys (Patrick); M.B. Leon (Martin); D.O. Williams (David); S.B. King 3rd (Spencer); B. Daniel; D.B. Mark (Daniel); J.M. Isner; D.R. Holmes Jr (David); S.G. Ellis (Stephen); K.L. Lee (Kerry); G.P. Keeler; L.G. Berdan (Lisa); T. Hinohara; R.M. Califf (Robert)

    1993-01-01

    textabstractBACKGROUND. Directional coronary atherectomy is a new technique of coronary revascularization by which atherosclerotic plaque is excised and retrieved from target lesions. With respect to the rate of restenosis and clinical outcomes, it is not known how this procedure compares with

  6. Coronary MR angiography: current status

    International Nuclear Information System (INIS)

    Danias, P.G.; Manning, W.J.

    2000-01-01

    Since first described in the early 1990s, coronary magnetic resonance angiography (MRA) has evolved as a promising noninvasive modality for imaging of the coronary arteries and evaluation of coronary artery disease. Despite technical limitations, coronary MRA has established value for imaging of anomalous coronary arteries and assessment of bypass graft patency. Current research focuses on the development of optimal respiratory compensation strategies, improved spatial and temporal resolution and faster acquisition of image data. The accurate detection of stenoses and assessment of the severity of coronary atherosclerosis is presently being evaluated with large multi-center studies. With further technique enhancements and more clinical experience, coronary MRA is likely to become the dominant noninvasive modality in clinical cardiology. (orig.) [de

  7. Stent implantation and vascular healing of a spontaneous coronary artery dissection assessed by optical coherence tomography in a patient with acute coronary syndrome

    DEFF Research Database (Denmark)

    Hansen, Kirstine Nørregaard; Antonsen, Lisbeth; Jensen, Lisette Okkels

    2018-01-01

    A 60-year old woman with non-ST-segment elevation myocardial infarction, underwent coronary angiogram combined with optical coherence tomography (OCT) revealing a long dissection in the right coronary artery. The patient experienced peri-procedural chest pain, the electrocardiogram showed ST...

  8. WebPASS Explorer (HR Personnel Management)

    Data.gov (United States)

    US Agency for International Development — WebPass Explorer (WebPASS Framework): USAID is partnering with DoS in the implementation of their WebPass Post Personnel (PS) Module. WebPassPS does not replace...

  9. Message passing for quantified Boolean formulas

    International Nuclear Information System (INIS)

    Zhang, Pan; Ramezanpour, Abolfazl; Zecchina, Riccardo; Zdeborová, Lenka

    2012-01-01

    We introduce two types of message passing algorithms for quantified Boolean formulas (QBF). The first type is a message passing based heuristics that can prove unsatisfiability of the QBF by assigning the universal variables in such a way that the remaining formula is unsatisfiable. In the second type, we use message passing to guide branching heuristics of a Davis–Putnam–Logemann–Loveland (DPLL) complete solver. Numerical experiments show that on random QBFs our branching heuristics give robust exponential efficiency gain with respect to state-of-the-art solvers. We also manage to solve some previously unsolved benchmarks from the QBFLIB library. Apart from this, our study sheds light on using message passing in small systems and as subroutines in complete solvers

  10. Preliminary analysis of proteome alterations in non-aneurysmal, internal mammary artery tissue from patients with abdominal aortic aneurysms

    DEFF Research Database (Denmark)

    Kidholm, Christina Lund; Beck, Hans Christian; Madsen, Julie Bukh

    2018-01-01

    with AAA and 33 sex- and age-matched controls without AAA. Samples were selected from a biobank of leftover internal mammary arterial tissue gathered at coronary by-pass operations. Results We identified and quantitated 877 proteins, of which 44 were differentially expressed between the two groups (nominal...

  11. Conventional blood conservation techniques in 500 consecutive coronary artery bypass operations.

    Science.gov (United States)

    Ovrum, E; Holen, E A; Abdelnoor, M; Oystese, R

    1991-09-01

    With use of a nonpharmacological, simple, and inexpensive program for blood conservation, 500 consecutive patients underwent elective coronary artery bypass grafting without need of homologous red cell transfusions in 493 (98.6%). At least one internal mammary artery was grafted in all but 1 patient, with supplemental saphenous vein grafts. Intraoperatively, autologous heparinized blood was removed before bypass and retransfused at the conclusion of extracorporeal circulation. The volume remaining in the oxygenator and tubing set was returned without cell processing or hemofiltration. Using the hard-shell cardiotomy reservoir from the heart-lung machine, autotransfusion of the shed mediastinal blood was continued hourly up to 18 hours after operation. The mean postoperative mediastinal blood loss was 643 +/- 354 mL, whereas 624 +/- 296 mL was autotransfused. Thirteen patients (2.6%) needed reexploration for bleeding, of whom 7 (7/500, 1.4%) received homologous blood. No other patients required red cell transfusions. In addition, 9 patients were given a mean of 2.6 units of fresh frozen plasma because of suspected coagulopathy. No platelets were transfused, and no cryoprecipitate therapy was undertaken. Thus, in total, 484 patients (96.8%) were not exposed to any homologous blood products during the hospital stay. At discharge, the mean hemoglobin concentration was 121 +/- 14 g/L (12.1 +/- 1.4 g/dL) and the hematocrit, 0.36 +/- 0.04. Postoperative complications were few. There was one in-hospital death (0.2%).

  12. The efficacy of hemodialysis in interventional therapy in coronary artery disease patients with chronic renal insufficiency.

    Science.gov (United States)

    Zhai, Hongxia; Li, Liang; Yin, Yaxin; Zhang, Jinjin; Chen, Haiwei; Liu, Runmei; Xia, Yun-feng

    2016-01-01

    The aim of this study was to explore the efficacy and safety of hemodialysis in interventional therapy for patients with coronary artery disease combined with chronic renal insufficiency. With the aging and social development, the number of coronary artery disease patients with chronic renal insufficiency gradually increased. Total 58 coronary heart disease patients with chronic renal dysfunction were selected. These patients were characterized with typical angina symptoms and typical electrocardiogram (ECG) changes of onset angina. Continuous oral administration of sodium bicarbonate tablets 1 g 3/day × 3 days and slow intravenous input sodium chloride 1000 ∼1500 mL 3-12 h before operation were given. By this way, all patients were treated by hydration and alkalization. After percutaneous coronary intervention (PCI) treatment, patients were immediately transferred to undergo 4 h of dialysis treatment without removing indwelling of femoral artery puncture sheath tube to protect renal function. Changes in renal function including serum creatinine, glomerular filtration rate, and urine were observed and recorded. All patients were successfully underwent PCI treatment. Within one month after PCI, there were no obvious complication and no stent thrombosis occurred. Among of 58 patients, 56 cases showed no significant increase in serum creatinine levels compared with those before operation. However, serum creatinine level of one patient increased to 251 umol/L and one patient still required permanent dialysis. Using hemodialysis in interventional therapy in coronary artery disease patients with chronic renal insufficiency could significantly improve the prognosis of the patients.

  13. Effects of exercise training on coronary transport capacity

    International Nuclear Information System (INIS)

    Laughlin, M.H.

    1985-01-01

    Coronary transport capacity was estimated in eight sedentary control and eight exercise-trained anesthetized dogs by determining the differences between base line and the highest coronary blood flow and permeability-surface area product (PS) obtained during maximal adenosine vasodilation with coronary perfusion pressure constant. The anterior descending branch of the left coronary artery was cannulated and pump- perfused under constant-pressure conditions (approximately equal to 100 Torr) while aortic, central venous, and coronary perfusion pressures, heart rate, electrocardiogram, and coronary flow were monitored. Myocardial extraction and PS of 51 Cr-labeled ethylenediaminetetraacetic acid were determined with the single-injection indicator-diffusion method. The efficacy of the 16 +/- 1 wk exercise training program was shown by significant increases in the succinate dehydrogenase activities of the gastrocnemius, gluteus medialis, and long head of triceps brachii muscles. There were no differences between control and trained dogs for either resting coronary blood flow or PS. During maximal vasodilation with adenosine, the trained dogs had significantly lower perfusion pressures with constant flow and, with constant-pressure vasodilation, greater coronary blood flow and PS. It is concluded that exercise training in dogs induces an increased coronary transport capacity that includes increases in coronary blood flow capacity (26% of control) and capillary diffusion capacity (82% of control)

  14. Coronary In-Stent Restenosis: Assessment with Corrected Coronary Opacification Difference across Coronary Stents Measured with CT Angiography.

    Science.gov (United States)

    Gao, Yang; Lu, Bin; Hou, Zhi Hui; Yu, Fang Fang; Yin, Wei Hua; Wang, Zhi Qiang; Wu, Yong Jian; Mu, Chao Wei; Meinel, Felix G; McQuiston, Andrew D; Schoepf, U Joseph

    2015-05-01

    To determine whether changes in coronary opacification normalized to the aorta (corrected coronary opacification [CCO]) across stents can help identify in-stent restenosis (ISR) severity with use of invasive coronary angiography as the standard of reference. This study was approved by the institutional review board, and the requirement to obtain informed consent was waived. The authors retrospectively analyzed 106 patients (88 men, 18 women; mean age, 59.6 years ± 10.4; age range, 36-84 years) who had previously undergone stent implantation within 3 months of coronary computed tomographic (CT) angiography. Attenuation values in the coronary lumen were measured proximal and distal to the stents and normalized to the descending aorta. The CCO difference across the stent was compared with the severity of ISR. One-way analysis of variance least significant difference was used for comparison. A total of 141 stents were assessed. Seventy-six stents were normally patent, 18 had ISR of less than 50%, 28 had ISR of 50%-99%, and 19 were fully occluded. The median CCO differences in the four groups were 0.078, 0.163, 0.346, and 0.606, respectively. There was no significant difference between stents with an ISR of at least 50% and those with total occlusion (P = .056), although the other groups had significant differences at pairwise comparison (P stents smaller than 3 mm in diameter, the median CCO differences in the four groups were 0.086, 0.136, 0.390, and 0.471, respectively. The CCO differences across normal stents and stents with ISR of less than 50% were significantly less than those across stents with an ISR of at least 50% and those with total occlusion (P stents with no ISR and those with an ISR of less than 50% (P = .821) and between stents with an ISR of at least 50% and those with an ISR of 100% (P = .836). The CCO difference across coronary stents is related to ISR severity in obstructive ISR in stents smaller than 3 mm in diameter. © RSNA, 2014.

  15. Forest Analysis by Single-Pass Millimeterwave SAR Tomography

    OpenAIRE

    Schmitt, Michael; Zhu, Xiao Xiang

    2016-01-01

    Recent investigations show that millimeterwave SAR tomography provides an interesting means for the analysis of forested areas, especially if single-pass systems are employed. Providing very high resolutions in the decimeter domain and highly coherent data also for slightly windy conditions, even individual trees can be considered. Besides, it has been shown that a certain amount of canopy penetration is possible in spite of the short wavelength.

  16. Relationship between coronary flow reserve evaluated by phase-contrast cine cardiovascular magnetic resonance and serum eicosapentaenoic acid

    Science.gov (United States)

    2013-01-01

    Background Long-term intake of long-chain n-3 polyunsaturated fatty acids (n-3 PUFAs), especially eicosapentaenoic acid (EPA) is associated with a low risk for cardiovascular disease. Phase-contrast cine cardiovascular magnetic resonance (PC cine CMR) can assess coronary flow reserve (CFR). The present study investigates the relationship between CFR evaluated by PC cine CMR and the serum EPA. Methods We studied 127 patients (male, 116 (91%); mean age, 72.2 ± 7.4 years) with known or suspected coronary artery disease (CAD). X-ray coronary angiography revealed no significant coronary arterial stenoses (defined as luminal diameter reduction ≥50% on quantitative coronary angiogram (QCA) analysis) in all study participants. Breath-hold PC cine CMR images of the coronary sinus (CS) were acquired to assess blood flow of the CS both at rest and during adenosine triphosphate (ATP) infusion. We calculated CFR as CS blood flow during ATP infusion divided by that at rest. Patients were allocated to groups according to whether they had high (n = 64, EPA ≥ 75.8 μg/mL) or low (n = 63, EPA  2.5, which is the previously reported lower limit of normal flow reserve without obstructive CAD. Multivariate analysis revealed that EPA is an independent predictor of CFR > 2.5 (odds ratio, 1.01; 95% confidence interval, 1.00 – 1.02, p = 0.008). Conclusions The serum EPA is significantly correlated with CFR in CAD patients without significant coronary artery stenosis. PMID:24359564

  17. Survival of Juvenile Chinook Salmon Passing the Bonneville Dam Spillway in 2007

    Energy Technology Data Exchange (ETDEWEB)

    Ploskey, Gene R.; Weiland, Mark A.; Hughes, James S.; Zimmerman, Shon A.; Durham, Robin E.; Fischer, Eric S.; Kim, Jina; Townsend, R. L.; Skalski, J. R.; Buchanan, Rebecca A.; McComas, Roy L.

    2008-12-01

    The U.S. Army Corps of Engineers Portland District (CENWP) funds numerous evaluations of fish passage and survival on the Columbia River. In 2007, the CENWP asked Pacific Northwest National Laboratory to conduct an acoustic telemetry study to estimate the survival of juvenile Chinook salmon passing the spillway at Bonneville Dam. This report documents the study results which are intended to be used to improve the conditions juvenile anadromous fish experience when passing through the dams that the Corps operates on the river.

  18. Complex Coronary Hemodynamics - Simple Analog Modelling as an Educational Tool.

    Science.gov (United States)

    Parikh, Gaurav R; Peter, Elvis; Kakouros, Nikolaos

    2017-01-01

    Invasive coronary angiography remains the cornerstone for evaluation of coronary stenoses despite there being a poor correlation between luminal loss assessment by coronary luminography and myocardial ischemia. This is especially true for coronary lesions deemed moderate by visual assessment. Coronary pressure-derived fractional flow reserve (FFR) has emerged as the gold standard for the evaluation of hemodynamic significance of coronary artery stenosis, which is cost effective and leads to improved patient outcomes. There are, however, several limitations to the use of FFR including the evaluation of serial stenoses. In this article, we discuss the electronic-hydraulic analogy and the utility of simple electrical modelling to mimic the coronary circulation and coronary stenoses. We exemplify the effect of tandem coronary lesions on the FFR by modelling of a patient with sequential disease segments and complex anatomy. We believe that such computational modelling can serve as a powerful educational tool to help clinicians better understand the complexity of coronary hemodynamics and improve patient care.

  19. Advantages in diagnosis of coronary artery disease by a combination of nuclear medicine methods

    International Nuclear Information System (INIS)

    Schmidt, H.A.E.; Birk, W.; Michele, E.

    1983-01-01

    Investigations on 106 patients with coronary artery disease were performed to improve the diagnosis of myocardial ischemia by combining myocardial scintigraphy and gated blood pool studies. The results show that it is possible to enhance the detection of coronary artery and to classify haemodynamic efficiency. In addition we found that in investigations performed on patients with arrhytmia and under stress conditions the 'hybrid-technique' is superior to the framemode acquisition method. (orig.) [de

  20. Spontaneous Recanalization of the Obstructed Right Coronary Artery Caused by Blunt Chest Trauma.

    Science.gov (United States)

    Haraguchi, Yumiko; Sakakura, Kenichi; Yamamoto, Kei; Taniguchi, Yousuke; Nakashima, Ikue; Wada, Hiroshi; Sanui, Masamitsu; Momomura, Shin-Ichi; Fujita, Hideo

    2018-03-30

    Blunt chest trauma can cause a wide variety of injuries including acute myocardial infarction (AMI). Although AMI due to coronary artery dissection caused by blunt chest trauma is very rare, it is associated with high morbidity and mortality. In the vast majority of patients with AMI, primary percutaneous coronary interventions (PCI) are performed to recanalize obstructed arteries, but PCI carries a substantial risk of hemorrhagic complications in the acute phase of trauma. We report a case of AMI due to right coronary artery (RCA) dissection caused by blunt chest trauma. The totally obstructed RCA was spontaneously recanalized with medical therapy. We could avoid primary PCI in the acute phase of blunt chest trauma because electrocardiogram showed early reperfusion signs. We performed an elective PCI in the subacute phase when the risk of bleeding subsided. Since the risk of severe hemorrhagic complications is greater in the acute phase of blunt chest trauma as compared with the late phase, deferring emergency PCI is reasonable if signs of recanalization are observed.

  1. Physiological assessment of coronary lesion severity: fractional flow reserve versus nonhyperaemic indices.

    Science.gov (United States)

    Robertson, Keith E; Hennigan, Barry; Berry, Colin; Oldroyd, Keith G

    2015-08-01

    Coronary angiography alone cannot accurately identify the haemodynamic impact of a coronary artery stenosis. Current international guidelines for myocardial revascularization recommend that inducible ischaemia should be demonstrated before the consideration of percutaneous coronary intervention. Invasive physiological assessment of coronary stenosis severity has increasingly been utilized for this purpose and use of the best validated technique, fractional flow reserve (FFR), has been shown to improve clinical outcomes in patients with stable and unstable coronary artery disease. This has led to the use of FFR being recommended in international revascularization guidelines, despite which, clinical uptake has been limited. One potential reason for slow adoption has been the requirement for maximal hyperaemia at the time of FFR measurement, usually achieved by the administration of pharmacological vasodilators such as adenosine. In some healthcare systems, adenosine is expensive and, in addition, its use can be associated with significant, albeit transient, adverse effects that patients (and some operators) find uncomfortable. Consequently, several methods of nonhyperaemic lesion assessment and their potential role in decision making have been reported. In this review we will review and discuss the current evidence for hyperaemic and nonhyperaemic methods of lesion assessment. We will also look at hybrid strategies that utilize both hyperaemic and nonhyperaemic methods as a means of potentially maintaining diagnostic accuracy while minimizing the requirement for adenosine administration and discuss whether or not they represent viable clinical alternatives.

  2. Assessment of coronary arteries in infants by 64-detector-row multislice spiral computed tomography

    International Nuclear Information System (INIS)

    Tahara, Masahiro; Waki, Chiaki; Komatsu, Hiroaki; Hayashi, Tomohiro; Sato, Tomoyasu

    2008-01-01

    Heart rate is one of the most important factors for optimal visualization of cardiac CT. We investigated the relation between heart rate and visibility of the coronary arteries with 64-detector row multislice spiral computed tomography (MSCT). Three simulated coronary artery stenosis models (3, 4, and 5 mm) were attached to a moving heart phantom and scanned using 64-detector row MSCT. The heart rate of the phantom was varied between 60 and 150 beats per minutes (bpm). The visibility of simulated coronary arteries was assessed in comparison between cardiac half reconstruction (CHR) and multi-sector reconstruction (MSR). Then contrast-enhanced 64-detector row MSCT was performed in 16 patients under 3 years of age with congenital heart disease and Kawasaki disease without heart rate control. The visibility of coronary artery segments was graded on a three-point scale. The simulated coronary artery patency was detected in the moving phantom at maximum heart rate (150 bpm) with MSR. Minimum lumen diameter was 0.75 mm. Electrocardiogram (ECG)-gated cardiac CT was performed in 9 patients, and non-ECG-gated cardiac CT was performed in 7 patients. The origin and proximal course of coronary arteries in all 9 patients with ECG-gated acquisition were visually evaluated. 64-detector row MSCT with ECG-gated acquisition is able to visualize the origin and proximal course of coronary arteries in infants under 3 years of age. (author)

  3. [Minimally invasive coronary artery surgery].

    Science.gov (United States)

    Zalaquett, R; Howard, M; Irarrázaval, M J; Morán, S; Maturana, G; Becker, P; Medel, J; Sacco, C; Lema, G; Canessa, R; Cruz, F

    1999-01-01

    There is a growing interest to perform a left internal mammary artery (LIMA) graft to the left anterior descending coronary artery (LAD) on a beating heart through a minimally invasive access to the chest cavity. To report the experience with minimally invasive coronary artery surgery. Analysis of 11 patients aged 48 to 79 years old with single vessel disease that, between 1996 and 1997, had a LIMA graft to the LAD performed through a minimally invasive left anterior mediastinotomy, without cardiopulmonary bypass. A 6 to 10 cm left parasternal incision was done. The LIMA to the LAD anastomosis was done after pharmacological heart rate and blood pressure control and a period of ischemic pre conditioning. Graft patency was confirmed intraoperatively by standard Doppler techniques. Patients were followed for a mean of 11.6 months (7-15 months). All patients were extubated in the operating room and transferred out of the intensive care unit on the next morning. Seven patients were discharged on the third postoperative day. Duplex scanning confirmed graft patency in all patients before discharge; in two patients, it was confirmed additionally by arteriography. There was no hospital mortality, no perioperative myocardial infarction and no bleeding problems. After follow up, ten patients were free of angina, in functional class I and pleased with the surgical and cosmetic results. One patient developed atypical angina on the seventh postoperative month and a selective arteriography confirmed stenosis of the anastomosis. A successful angioplasty of the original LAD lesion was carried out. A minimally invasive left anterior mediastinotomy is a good surgical access to perform a successful LIMA to LAD graft without cardiopulmonary bypass, allowing a shorter hospital stay and earlier postoperative recovery. However, a larger experience and a longer follow up is required to define its role in the treatment of coronary artery disease.

  4. Influence of psychological and coronary parameters on coronary patient rehospitalization

    Directory of Open Access Journals (Sweden)

    Nikolić Gordana

    2010-01-01

    Full Text Available Introduction. Psychological reactions are often comorbid with coronary risk factors and could be important for a six-month outcome. Objective. Determination of anxiety level, depression and aggression, persistence of risk health behaviour, stress life events, and coronary risk factors after coronary event and a predictive value of those parameters for six-month rehospitalization. Methods. In the group with Angina Pectoris (E1=30 and the group with Acute Myocardial Infarction (E2=33, there were applied, at baseline and after 6 months, the following: Semistructured Clinical Interview based on ICD-10, for depressive episode and anxiety disorder, Hamilton Anxiety Scale (HAMA, Hamilton Depression Scale (HAMD, KON-6 sigma Scale for aggression, Holms-Rahe Scale (H-R for stress events and Questionnaire for risk behaviour: alcohol consumption, smoking, lack of physical activity. Group differences were assessed by t-test and chi-square test, p<0.05, regression analysis for assessing initial variables, a predictive value for six month rehospitalization. Results. After acute coronary event, the anxiety and depression levels were mild and aggression was low in E1 and mild in E2. Stress event score was significantly higher in E2 (H-R=115.18 than in E1 (H-R=72.20, p<0.05. After 6 months, the results were the same except for a significantly lower stress event score in E1 (H-R=49.48, and in E2 (H-R=91.65, but still significantly higher than in E1. Coronary parameters were reduced, smokers' rate was increased in E1. Alcohol consumption, hypercholesterolaemia and hereditary tendency were predictive for six- month rehospitalization. Conclusion. After acute cardiac event, hospitalized coronary patients had a mild anxiety, depression and aggression level as well as after six months. The infarct patients had experienced more stress life events in the previous year than the angina patients. Risk health behaviour did not change in the following six months, with the

  5. CT coronary angiography versus conventional invasive coronary angiography. The view of the referring physician

    Energy Technology Data Exchange (ETDEWEB)

    Maurer, Martin H. [Charite - Universitaetsmedizin Berlin (Germany). Dept. of Radiology; Universitaetsspital Bern (Switzerland). Dept. fuer Diagnostische, Interventionelle und Paediatrische Radiologie; Zimmermann, E.; Hamm, B. [Charite - Universitaetsmedizin Berlin (Germany). Dept. of Radiology; Dewey, M.

    2014-12-15

    Assessment of experience gained by local referring physicians with the procedure of coronary computed tomographic angiography (CCTA) in the everyday clinical routine. A 25-item questionnaire was sent to 179 physicians, who together had referred a total of 1986 patients for CCTA. They were asked about their experience to date with CCTA, the indications for coronary imaging, and their practice in referring patients for noninvasive CCTA or invasive catheter angiography. 53 questionnaires (30%) were assessable, corresponding to more than 72% of the patients referred. Of the referring physicians who responded, 94% saw a concrete advantage of CCTA in the treatment of patients, whereby 87% were 'satisfied' or 'very satisfied' with the reporting. For excluding coronary heart disease (CHD) where there was a low pre-test probability of disease, the physicians considered CCTA to be superior to conventional coronary diagnosis (4.2 on a scale of 1-5) and vice versa for acute coronary syndrome (1.6 of 5). The main reasons for unsuitability of CCTA for CT diagnosis were claustrophobia and the absence of a sinus rhythm. The level of exposure to radiation in CCTA was estimated correctly by only 42% of the referring physicians. 90% of the physicians reported that their patients evaluated their coronary CT overall as 'positive' or 'neutral', while 87% of the physicians whose patients had undergone both procedures reported that the patients had experienced CCTA as the less disagreeable of the two. CCTA is accepted by the referring physicians as an alternative imaging procedure for the exclusion of CHD and received a predominantly positive assessment from both the referring physicians and the patients.

  6. Functional significance of coronary collateral circulation during dynamic exercise evaluated by thallium-201 myocardial scintigraphy

    International Nuclear Information System (INIS)

    Wainwright, R.J.; Maisey, M.N.; Edwards, A.C.; Sowton, E.

    1980-01-01

    Sixty-five patients with angiographically documented coronary artery disease were investigated by thallium-201 ( 201 Tl) scintigraphy to determine the role of the collateral circulation during dynamic exercise. Fifty-three patients had complete proximal occlusion of at least one major coronary artery. One patient had total occlusion of all three major coronary arteries. Sixty-four collateral channels were identified, graded, and compared with corresponding regions of the myocardial scintigram. Tracer uptake was also graded and classified as various degrees of protection from ischaemia. A significant correlation between good collaterals with complete protection and poor or absent collaterals with no protection was noted. Seventeen patients (20 occluded vessels) had total coronary occlusion without myocardial infarction. Collaterals conferred protection in 9/15 occlusions whereas no protection was seen in five occlusions without collaterals. There was no difference in the protective role of homocoronary and heterocoronary collateral vessels. Hypertrophy of the first septal left anterior descending perforator conferred significant protection from ischaemia in contrast to bridging collaterals and ghosting. During exercise the right coronary bed is preferentially protected from ischaemia, in contrast to the left anterior descending territory. This probably reflects the direction of a transmural flow gradient between left and right ventricles during exercise. (author)

  7. Nuclear medical quality control of transluminal coronary angioplastic (TCA)

    International Nuclear Information System (INIS)

    Klepzig, H. Jr.; Scherer, D.; Kober, G.; Kaltenbach, M.; Maul, F.D.; Standke, R.; Hoer, G.; Kanemoto, N.

    1984-01-01

    To assess the results of transluminal coronary angioplasty 48 patients with coronary heart disease were investigated at rest and during exercise with the ECG (46 patients), thallium-201 myocardial scintigraphy (26 patients), and equilibrium radionuclide ventriculography (38 patients). Exercise stress test was quantified by means of an ischemia score, myocardial scintigraphy by an vitality index and by corresponding redistribution factors, and radionuclide ventriculography by ejection fraction and maximum systolic volume change as a fraction of enddiastolic volume. The patients were divided into three groups: 36 patients had successful TCA (group 1); 6 patients underwent aortocoronary bypass operation (ACB, group 2); in 6 patients TCA was unsuccessful, they served as control (group 3). On average TCA yielded a reduction of coronary artery stenosis from 83% to 44%. Functional improvement was comparable in group 1 and 2: Ischemia score was reduced significantly. Perfusion index increased, the corresponding redistribution factors decreased. Left ventricular ejection fraction increased at rest and during exercise. Maximum systolic volume change increased correspondingly. Only slight changes were noted in group 3. Three months later 2 of 16 reinvestigated patients showed a restenosis and one a new narrowing distal to the successfully dilated stenosis. Functional deterioration could be demonstrated in these, whilst maintainance of the good functional results was documented in the others. (orig./MG) [de

  8. Coronary Angiography Findings and Its Determinants in Patients Presenting With Acute Coronary Syndrome: A Descriptive Analysis from Asian Population.

    Science.gov (United States)

    Chourasiya, M; Satheesh, S; Selvaraj, R; Jayaraman, B; Pillai, A A

    2017-10-01

    The aim was to study the angiographic profile in patients presented as acute coronary syndrome and its relation with risk factors and comparison between genders. This prospective observational study was performed on total 352 patients of acute coronary syndrome were analyzed for various risk factors, angiographic pattern in Jawaharlal Institute of Postgraduate Medical Education and Research (JIPMER), Puducherry, South India from January 2015 to July 2016. Mean age of presentation was 52.62±11.63 years. Male were 271(77.0%) and female were 81(23.0%). Majority of patients were STEMI (67.6%) followed by UA (24.4%) and NSTEMI (8%). Smoker was 117(33.3%) patients. Hypertensive were 124(35.2%) of patients and 149(42.3%) were diabetics. Family history of CAD was positive in 45(12.8%). On angiographic evaluation left main reference diameter was lower in females (4.02±0.72) than males (4.07±0.82). LAD was most commonly involved followed by RCA and LCX among all three group of acute coronary syndrome. Left main was least involved (8.3%). In STEMI SVD (40.3%) was most common presentation, after that DVD was seen in 22.3%, TVD in 10.5%, non-obstructive coronary was seen in 16% of patients and normal coronary was seen in 11% of patients. In UA 28%, 22.8%, 13.2%, 15.8%, 20.2% was seen in SVD, DVD, TVD, non-obstructive and normal coronary respectively. Long length coronary lesions (>20mm) were seen in majority in all type of acute coronary syndrome. Coronary lesion length was not associated with presentation acute coronary syndrome and genders. Male were most commonly presented as acute coronary syndrome. STEMI was most common presentation. Diabetic was most prevalent risk factor. SVD was most common angiographic pattern and LAD was most common involved arteries.

  9. Adverse effects in coronary angiography: a comparative study of different temperature contrast medium

    International Nuclear Information System (INIS)

    Zhou Peng; Wang Qiulin; Cai Guocai; Li Lu; Jiang Licheng; Yang Zhen; Huang Xiuping

    2011-01-01

    Objective: To investigate the correlation between different temperature contrast medium and the occurrence of adverse effects, including the chest discomfort, the changes of heart rate, ST segment and T wave, the operating time and the used dosage of contrast medium, in performing coronary angiography. Methods: According to the contrast medium temperature used in coronary angiography, the patients were randomly divided into two groups: room temperature group (n=521) and warm temperature group (n=522). The contrast medium used in warm temperature group was bathed in 37 ℃ water for 60 minutes when the coronary angiography was carried out. The T Wave amplitude changes ≥ 0.01 mv, ST segment depression ≥ 0.05 mv, changes in heart rate ≥ 10 times/min were brought into the positive accounting. The occurrence of adverse effects, such as palpitation, chest distress and pectoralgia, the operative time and the used dosage of contrast medium were recorded. The results were analyzed and compared between the two groups. Results: Statistically significant differences in the changes of heart rate, ST segment deviation, T wave change and operating time existed between the two groups (P<0.05). And the difference in the occurrence of adverse effects between the two groups was also statistically significant (P<0.05). Conclusion: When performing coronary angiography, warming of the contrast medium with water bath is greatly conducive to the prevention of cardiac adverse effects. (authors)

  10. Physiologic assessment of coronary artery fistula

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, N.C.; Beauvais, J. (Creighton Univ., Omaha, NE (USA))

    1991-01-01

    Coronary artery fistula is an uncommon clinical entity. The most common coronary artery fistula is from the right coronary artery to the right side of the heart, and it is less frequent to the pulmonary artery. The effect of a coronary artery fistula may be physiologically significant because of the steal phenomenon resulting in coronary ischemia. Based on published reports, it is recommended that patients with congenital coronary artery fistulas be considered candidates for elective surgical correction to prevent complications including development of congestive heart failure, angina, subacute bacterial endocarditis, myocardial infarction, and coronary aneurysm formation with rupture or embolization. A patient is presented in whom treadmill-exercise thallium imaging was effective in determining the degree of coronary steal from a coronary artery fistula, leading to successful corrective surgery.

  11. Physiologic assessment of coronary artery fistula

    International Nuclear Information System (INIS)

    Gupta, N.C.; Beauvais, J.

    1991-01-01

    Coronary artery fistula is an uncommon clinical entity. The most common coronary artery fistula is from the right coronary artery to the right side of the heart, and it is less frequent to the pulmonary artery. The effect of a coronary artery fistula may be physiologically significant because of the steal phenomenon resulting in coronary ischemia. Based on published reports, it is recommended that patients with congenital coronary artery fistulas be considered candidates for elective surgical correction to prevent complications including development of congestive heart failure, angina, subacute bacterial endocarditis, myocardial infarction, and coronary aneurysm formation with rupture or embolization. A patient is presented in whom treadmill-exercise thallium imaging was effective in determining the degree of coronary steal from a coronary artery fistula, leading to successful corrective surgery

  12. Cerebroprotective effect of piracetam in patients undergoing coronary bypass burgery.

    Science.gov (United States)

    Holinski, Sebastian; Claus, Benjamin; Alaaraj, Nour; Dohmen, Pascal Maria; Kirilova, Kremena; Neumann, Konrad; Uebelhack, Ralf; Konertz, Wolfgang

    2008-11-01

    Reduction of cognitive function is a possible side effect after cardiac surgery using cardiopulmonary bypass. We investigated the cerebroprotective effect of piracetam on cognitive performance in patients undergoing coronary artery bypass surgery under cardiopulmonary bypass. Patients scheduled for elective, primary and isolated coronary bypass surgery were randomised either to piracetam or placebo group. The study was performed in a double blind fashion. Patients received either 12 g piracetam or placebo at the beginning of the operation. Six neuropsychological subtests from the Syndrom Kurz Test and the Alzheimer's Disease Assessment Scale were performed preoperatively and on the third postoperative day. To assess the overall cognitive function and the degree of cognitive decline across all tests after surgery we combined the six test-scores by principal component analysis. A total number of 120 patients were enrolled into the study. Preoperative overall cognitive function were not significantly different between the groups. The postoperative combined score of the neuropsychological tests showed a deterioration of cognitive function in both groups (placebo-pre: -0.06+/-0.99 vs placebo-post: -1.38+/-1.11; ppiracetam-pre: 0.06+/-1.02 vs piracetam-post: -0.65+/-0.93; ppiracetam patients performed significantly better compared to the placebo patients after the operation and had a less decline of overall cognitive function (pPiracetam has a cerebroprotective effect in patients undergoing coronary artery bypass surgery with the use of cardiopulmonary bypass. It reduces an early postoperative substantial decline of neuropsychological abilities.

  13. Myocardial segmentation based on coronary anatomy using coronary computed tomography angiography: Development and validation in a pig model

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Mi Sun [Chung-Ang University College of Medicine, Department of Radiology, Chung-Ang University Hospital, Seoul (Korea, Republic of); Yang, Dong Hyun; Seo, Joon Beom; Kang, Joon-Won; Lim, Tae-Hwan [Asan Medical Center, University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Seoul (Korea, Republic of); Kim, Young-Hak; Kang, Soo-Jin; Jung, Joonho [Asan Medical Center, University of Ulsan College of Medicine, Heart Institute, Seoul (Korea, Republic of); Kim, Namkug [Asan Medical Center, University of Ulsan College of Medicine, Department of Convergence Medicine, Seoul (Korea, Republic of); Heo, Seung-Ho [Asan Medical Center, University of Ulsan College of Medicine, Asan institute for Life Science, Seoul (Korea, Republic of); Baek, Seunghee [Asan Medical Center, University of Ulsan College of Medicine, Department of Clinical Epidemiology and Biostatistics, Seoul (Korea, Republic of); Choi, Byoung Wook [Yonsei University, Department of Diagnostic Radiology, College of Medicine, Seoul (Korea, Republic of)

    2017-10-15

    To validate a method for performing myocardial segmentation based on coronary anatomy using coronary CT angiography (CCTA). Coronary artery-based myocardial segmentation (CAMS) was developed for use with CCTA. To validate and compare this method with the conventional American Heart Association (AHA) classification, a single coronary occlusion model was prepared and validated using six pigs. The unstained occluded coronary territories of the specimens and corresponding arterial territories from CAMS and AHA segmentations were compared using slice-by-slice matching and 100 virtual myocardial columns. CAMS more precisely predicted ischaemic area than the AHA method, as indicated by 95% versus 76% (p < 0.001) of the percentage of matched columns (defined as percentage of matched columns of segmentation method divided by number of unstained columns in the specimen). According to the subgroup analyses, CAMS demonstrated a higher percentage of matched columns than the AHA method in the left anterior descending artery (100% vs. 77%; p < 0.001) and mid- (99% vs. 83%; p = 0.046) and apical-level territories of the left ventricle (90% vs. 52%; p = 0.011). CAMS is a feasible method for identifying the corresponding myocardial territories of the coronary arteries using CCTA. (orig.)

  14. [THE INFLUENCE OF MONO- AND MULTIVASCULAR LESIONS OF CORONARY ARTERIES ON THE COURSE OF CORONARY HEART DISEASE IN PATIENTS WITH DIABETES MELLITUS TYPE 2].

    Science.gov (United States)

    Sypalo, A; Kravchun, P; Kadykova, O

    2017-03-01

    The article assesses the influence of mono- and multivascular lesions of coronary arteries on the course of coronary heart disease at patients with diabetes mellitus type 2. For this purpose, a comprehensive survey of 75 patients with coronary heart disease and diabetes mellitus type 2 was arranged. Depending on the number of vascular lesions of the coronary arteries, according to the data of coronary arteries computer tomography, all patients were divided into two subgroups. The first subgroup included 27 patients with coronary heart disease and diabetes mellitus type 2 with monovascular lesions of coronary arteries. To the second subgroup were included 48 patients with coronary heart disease and diabetes mellitus type 2 with multivascular lesions of coronary arteries. During the analysis of carbohydrate metabolism in cases of coronary heart disease and diabetes mellitus type 2 the HOMA index increase by 25.40% and insulin level increase by 17.05% were revealed at patients with multivascular lesions of coronary arteries in comparison with patients with monovascular lesions of coronary arteries, respectively. The combination of coronary heart disease and diabetes mellitus type 2 with multivascular lesions of coronary arteries was associated with an increase of sortilin level (233,47±47,85 ng/l). A significant increase in triglycerides, lipoprotein cholesterol of very low density influences greatly on the progression of coronary atherosclerosis with lesions of greater number of coronary arteries at patients surveyed. At patients with coronary heart disease and diabetes mellitus type 2 with multivascular lesions of coronary arteries the left ventricle myocardial re-modeling occurred through the increase of left ventricle's size and cavity.

  15. Coronary heart disease

    Science.gov (United States)

    Heart disease, Coronary heart disease, Coronary artery disease; Arteriosclerotic heart disease; CHD; CAD ... buildup of plaque in the arteries to your heart. This may also be called hardening of the ...

  16. Digital remote viewing system for coronary care unit

    International Nuclear Information System (INIS)

    Cho, P.S.; Tillisch, J.; Huang, H.K.

    1987-01-01

    A digital remote viewing system developed for the coronary care unit at the UCLA Medical Center has been in clinical operation since March 1, 1987. The present system consists of three 512-line monitors, VAX 11/750, Gould IP8500 image processor and a broad-band communication system. The patients' images are acquired with a computed radiography system and are transmitted to the coronary care unit, which is five floors above the radiology department. This exhibit presents the architecture and the performance characteristics of the system. Also, the second-generation system, which consists of an intelligent local work station with three 1,024-line monitors and a fast digital communication network, will be introduced

  17. Coronary artery anatomy and variants

    Energy Technology Data Exchange (ETDEWEB)

    Malago, Roberto; Pezzato, Andrea; Barbiani, Camilla; Alfonsi, Ugolino; Nicoli, Lisa; Caliari, Giuliana; Pozzi Mucelli, Roberto [Policlinico G.B. Rossi, University of Verona, Department of Radiology, Verona (Italy)

    2011-12-15

    Variants and congenital anomalies of the coronary arteries are usually asymptomatic, but may present with severe chest pain or cardiac arrest. The introduction of multidetector CT coronary angiography (MDCT-CA) allows the detection of significant coronary artery stenosis. Improved performance with isotropic spatial resolution and higher temporal resolution provides a valid alternative to conventional coronary angiography (CCA) in many patients. MDCT-CA is now considered the ideal tool for three-dimensional visualization of the complex and tortuous anatomy of the coronary arteries. With multiplanar and volume-rendered reconstructions, MDCT-CA may even outperform CCA in determining the relative position of vessels, thus providing a better view of the coronary vascular anatomy. The purpose of this review is to describe the normal anatomy of the coronary arteries and their main variants based on MDCT-CA with appropriate reconstructions. (orig.)

  18. Assessment Of Coronary Arterial Stents By Multislice-CT Angiography

    International Nuclear Information System (INIS)

    Maintz, D.; Fallenberg, E. M.; Heindel, W.; Fischbach, R.; Grude, M.

    2003-01-01

    Purpose: To assess patency and lumen visibility of coronary artery stents by multislice-CT angiography (MSCTA) in comparison with conventional coronary angiography as the standard of reference. Material and Methods: 47 stents of 13 different types were evaluated in 29 patients. MSCTA was performed on a 4-slice scanner with a standard coronary protocol (detector collimation 4 x 1 mm; table feed 1.5 mm/rotation, 400 mAs, 120 kV). Image evaluation was performed by two readers who were blinded to the reports from the catheter angiography. MIP reconstructions were evaluated for image quality on a 4-point scale (1 = poor, 4 = excellent) and stent patency (contrast distal to the stent as an indirect patency sign). Axial images and multiplanar reformations through the stents were used for assessment of stent lumen visibility (measurement of the visible stent lumen diameter) and detection of relevant in-stent stenosis (50%). Results: Image quality was fair to good on average (score 2.64 ± 1.0) and depended on the heart rate (heart rate 45-60: average score 3.2, heart rate 61-70: average score 2.8, heart rate >71: average score 1.4). Thirty-seven stents were correctly classified as patent, 1 was correctly classified as occluded and 9 stents were not assessable due to insufficient image quality because of triggering artifacts. Parts of the stent lumen could be visualized in 30 cases. On average, 20-40% of the stent lumen diameter was visible. Twenty-five stents were correctly classified as having no stenosis, 1 was falsely classified as stenosed, 1 was correctly classified as occluded. In 20 stents lumen visibility was not sufficient for stenosis evaluation. Conclusion: Although the stent lumen may be partly visualized in most stents, a reliable evaluation of in-stent stenoses does not seem practical by 4-slice MSCT. Nevertheless, for stent patency evaluation, MS-CTA might provide valuable clinical information. With submillimeter MSCT (e.g. 16-slice scanners) and more

  19. Coronary stent on coronary CT angiography: Assessment with model-based iterative reconstruction technique

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Chae; Kim, Yeo Koon; Chun, Eun Ju; Choi, Sang IL [Dept. of of Radiology, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of)

    2016-05-15

    To assess the performance of model-based iterative reconstruction (MBIR) technique for evaluation of coronary artery stents on coronary CT angiography (CCTA). Twenty-two patients with coronary stent implantation who underwent CCTA were retrospectively enrolled for comparison of image quality between filtered back projection (FBP), adaptive statistical iterative reconstruction (ASIR) and MBIR. In each data set, image noise was measured as the standard deviation of the measured attenuation units within circular regions of interest in the ascending aorta (AA) and left main coronary artery (LM). To objectively assess the noise and blooming artifacts in coronary stent, we additionally measured the standard deviation of the measured attenuation and intra-luminal stent diameters of total 35 stents with dedicated software. All image noise measured in the AA (all p < 0.001), LM (p < 0.001, p = 0.001) and coronary stent (all p < 0.001) were significantly lower with MBIR in comparison to those with FBP or ASIR. Intraluminal stent diameter was significantly higher with MBIR, as compared with ASIR or FBP (p < 0.001, p = 0.001). MBIR can reduce image noise and blooming artifact from the stent, leading to better in-stent assessment in patients with coronary artery stent.

  20. Experimental and Numerical Evaluation of the By-Pass Flow in a Catalytic Plate Reactor for Hydrogen Production

    DEFF Research Database (Denmark)

    Sigurdsson, Haftor Örn; Kær, Søren Knudsen

    2011-01-01

    Numerical and experimental study is performed to evaluate the reactant by-pass flow in a catalytic plate reactor with a coated wire mesh catalyst for steam reforming of methane for hydrogen generation. By-pass of unconverted methane is evaluated under different wire mesh catalyst width to reactor...

  1. Breath-hold two-dimensional MR angiography of coronary arteries. Comparison with conventional coronary angiography in ten cases

    International Nuclear Information System (INIS)

    Li Liwei; Zhang Wanshi; Liu Chaozhong; Lu Xiaoyan; Xu Jiaxing

    1997-01-01

    Purpose: To assess the diagnostic value of two-dimensional coronary magnetic resonance (MR) angiography in patients evaluated for ischemic heart disease. Materials and methods: Ten patients who underwent selective cardiac catheterization with coronary MR angiography were evaluated with two-dimensional coronary MR angiography. Coronary MR angiography was performed with breath-hold fat-suppressed ECG-gated Turbo-FLASH with K-space segmentation using a 1.5 T imager. Results: The left main coronary artery, proximal left anterior descending artery, circumflex artery and right coronary artery were demonstrated in all cases. Continuous segments (mean) of left anterior descending, circumflex and right coronary arteries visualized on MRA were 6.72 +- 3.16 cm, 3.67 +- 4.81 cm and 7.93 +- 3.12 cm respectively. The overall sensitivity for detection of hemodynamically significant coronary artery lesion (≥50%) was 62.5% respectively. Conclusion: Breath-hold two-dimensional coronary MR angiography was useful in showing relatively long segments of the main coronary arteries and also has potential in depicting hemodynamically significant coronary artery lesions

  2. Coronary artery analysis: Computer-assisted selection of best-quality segments in multiple-phase coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Chuan, E-mail: chuan@umich.edu; Chan, Heang-Ping; Hadjiyski, Lubomir M.; Chughtai, Aamer; Wei, Jun; Kazerooni, Ella A. [Department of Radiology, The University of Michigan, Ann Arbor, Michigan 48109-0904 (United States)

    2016-10-15

    Purpose: The authors are developing an automated method to identify the best-quality coronary arterial segment from multiple-phase coronary CT angiography (cCTA) acquisitions, which may be used by either interpreting physicians or computer-aided detection systems to optimally and efficiently utilize the diagnostic information available in multiple-phase cCTA for the detection of coronary artery disease. Methods: After initialization with a manually identified seed point, each coronary artery tree is automatically extracted from multiple cCTA phases using our multiscale coronary artery response enhancement and 3D rolling balloon region growing vessel segmentation and tracking method. The coronary artery trees from multiple phases are then aligned by a global registration using an affine transformation with quadratic terms and nonlinear simplex optimization, followed by a local registration using a cubic B-spline method with fast localized optimization. The corresponding coronary arteries among the available phases are identified using a recursive coronary segment matching method. Each of the identified vessel segments is transformed by the curved planar reformation (CPR) method. Four features are extracted from each corresponding segment as quality indicators in the original computed tomography volume and the straightened CPR volume, and each quality indicator is used as a voting classifier for the arterial segment. A weighted voting ensemble (WVE) classifier is designed to combine the votes of the four voting classifiers for each corresponding segment. The segment with the highest WVE vote is then selected as the best-quality segment. In this study, the training and test sets consisted of 6 and 20 cCTA cases, respectively, each with 6 phases, containing a total of 156 cCTA volumes and 312 coronary artery trees. An observer preference study was also conducted with one expert cardiothoracic radiologist and four nonradiologist readers to visually rank vessel segment

  3. Coronary artery analysis: Computer-assisted selection of best-quality segments in multiple-phase coronary CT angiography

    International Nuclear Information System (INIS)

    Zhou, Chuan; Chan, Heang-Ping; Hadjiyski, Lubomir M.; Chughtai, Aamer; Wei, Jun; Kazerooni, Ella A.

    2016-01-01

    Purpose: The authors are developing an automated method to identify the best-quality coronary arterial segment from multiple-phase coronary CT angiography (cCTA) acquisitions, which may be used by either interpreting physicians or computer-aided detection systems to optimally and efficiently utilize the diagnostic information available in multiple-phase cCTA for the detection of coronary artery disease. Methods: After initialization with a manually identified seed point, each coronary artery tree is automatically extracted from multiple cCTA phases using our multiscale coronary artery response enhancement and 3D rolling balloon region growing vessel segmentation and tracking method. The coronary artery trees from multiple phases are then aligned by a global registration using an affine transformation with quadratic terms and nonlinear simplex optimization, followed by a local registration using a cubic B-spline method with fast localized optimization. The corresponding coronary arteries among the available phases are identified using a recursive coronary segment matching method. Each of the identified vessel segments is transformed by the curved planar reformation (CPR) method. Four features are extracted from each corresponding segment as quality indicators in the original computed tomography volume and the straightened CPR volume, and each quality indicator is used as a voting classifier for the arterial segment. A weighted voting ensemble (WVE) classifier is designed to combine the votes of the four voting classifiers for each corresponding segment. The segment with the highest WVE vote is then selected as the best-quality segment. In this study, the training and test sets consisted of 6 and 20 cCTA cases, respectively, each with 6 phases, containing a total of 156 cCTA volumes and 312 coronary artery trees. An observer preference study was also conducted with one expert cardiothoracic radiologist and four nonradiologist readers to visually rank vessel segment

  4. Assessment of coronary artery aneurysms in paediatric patients with Kawasaki disease by multidetector row CT angiography: feasibility and comparison with 2D echocardiography

    International Nuclear Information System (INIS)

    Chu, W.C.W.; Lam, W.W.M.; Mok, G.C.F.; Yam, M.; Sung, R.Y.T.

    2006-01-01

    Transthoracic ECHO is the locally accepted method for coronary surveillance of patients with Kawasaki disease but it may have limited visualization in the older child. To assess the feasibility of multidetector CT (MDCT) angiography in the follow-up of coronary artery aneurysms in children with previous Kawasaki disease. Six children (5 boys, 1 girl; mean age 11.5 years) with known Kawasaki disease and coronary artery involvement underwent CT coronary angiography using 16-detector MDCT. The visualized lengths and diameter of all coronary segments were measured. The number, size and location of coronary artery aneurysms were recorded and compared with recent ECHO. Twelve coronary artery aneurysms (seven saccular, five fusiform) were identified by MDCT angiography. One saccular aneurysm at the junction of the distal right coronary artery and posterior descending artery was not detected by ECHO while the remaining six in proximal segments were detected by both modalities. Two of five fusiform aneurysms were not detected by ECHO due to their small sizes. Excellent agreement was found between CT and ECHO for maximal diameter and length of the visualized aneurysms. MDCT angiography accurately defines coronary artery aneurysms. It is more sensitive for detecting aneurysms at distal coronary segments and fusiform aneurysms of small size

  5. Arterial bending angle and wall morphology correlate with slow coronary flow: Determination with multidetector CT coronary angiography

    International Nuclear Information System (INIS)

    Kantarci, Mecit; Guendogdu, Fuat; Doganay, Selim; Duran, Cihan; Kalkan, M. Emin; Sagsoz, M. Erdem; Kucuk, Osman; Karakaya, Afak; Kucuk, Ahmet; Akguen, Metin

    2011-01-01

    Background and purpose: The purpose of this study was to assess angulations and vessel wall morphology that could lead to bending head loss in the RCA and LMCA arteries of patients with slow coronary flow (SCF) evaluated by MDCT coronary angiography. Methods: The study involved 51 patients (45 males, mean age: 59.6 years) who were diagnosed with SCF by coronary angiography. Diagnosis of SCF was based on thrombolysis in myocardial infarction (TIMI) frame count. Fifty-one patients with absence of slow flow were selected as the control group. The angulations of the main coronary arteries with the aorta were measured from the axial images obtained through MDCT coronary angiography, and the findings were recorded. In addition, the coronary artery walls of these patients were evaluated. For statistical analysis, SPSS for Windows 10.0 (SPSS Inc., Chicago, IL) was used. For comparisons of the angles, either independent samples t test or the Mann-Whitney U test was used where appropriate. Results: The results of the study indicated that 38 patients had SCF in the LAD. Comparisons of patients with SCF with the controls revealed that in the patients with SCF, the mean angle of the LMCA with the aorta (40.9 ± 20.5 o ) was statistically significantly smaller than the mean angle of the LMCA with the aorta in the control cases (71.8 ± 11 o ). In 12 patients, slow flow was detected in the RCA. Those with slow flow in the RCA had significantly smaller angles (mean: 33.2 ± 20.4 o ) than the other cases (mean: 78.9 ± 10.7 o ). Conclusion: A small angle of origin of the main coronary arteries from the aorta, measured on MDCT examinations is correlated with slow blood flow in those vessels, as calculated by the TIMI frame count in catheter coronary angiography.

  6. Arterial bending angle and wall morphology correlate with slow coronary flow: Determination with multidetector CT coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Kantarci, Mecit, E-mail: akkanrad@hotmail.com [Department of Radiology, Medical Faculty, Atatuerk University, Erzurum (Turkey); Guendogdu, Fuat [Department of Cardiology, Medical Faculty, Atatuerk University, Erzurum (Turkey); Doganay, Selim [Department of Radiology, Medical Faculty, Erciyes University, Kayseri (Turkey); Duran, Cihan [Department of Radiology, Bilim University, Florence Nightingale Hospital, Istanbul (Turkey); Kalkan, M. Emin [Department of Cardiology, Medical Faculty, Atatuerk University, Erzurum (Turkey); Sagsoz, M. Erdem [Department of Radiology, Medical Faculty, Atatuerk University, Erzurum (Turkey); Kucuk, Osman [Department of Electronic Engineering, Engineering Faculty, Atatuerk University, Erzurum (Turkey); Karakaya, Afak [Department of Radiology, Medical Faculty, Atatuerk University, Erzurum (Turkey); Kucuk, Ahmet [Department of Mathematics, Science Faculty, Atatuerk University, Erzurum (Turkey); Akguen, Metin [Department of Chest, Medical Faculty, Atatuerk University, Erzurum (Turkey)

    2011-01-15

    Background and purpose: The purpose of this study was to assess angulations and vessel wall morphology that could lead to bending head loss in the RCA and LMCA arteries of patients with slow coronary flow (SCF) evaluated by MDCT coronary angiography. Methods: The study involved 51 patients (45 males, mean age: 59.6 years) who were diagnosed with SCF by coronary angiography. Diagnosis of SCF was based on thrombolysis in myocardial infarction (TIMI) frame count. Fifty-one patients with absence of slow flow were selected as the control group. The angulations of the main coronary arteries with the aorta were measured from the axial images obtained through MDCT coronary angiography, and the findings were recorded. In addition, the coronary artery walls of these patients were evaluated. For statistical analysis, SPSS for Windows 10.0 (SPSS Inc., Chicago, IL) was used. For comparisons of the angles, either independent samples t test or the Mann-Whitney U test was used where appropriate. Results: The results of the study indicated that 38 patients had SCF in the LAD. Comparisons of patients with SCF with the controls revealed that in the patients with SCF, the mean angle of the LMCA with the aorta (40.9 {+-} 20.5{sup o}) was statistically significantly smaller than the mean angle of the LMCA with the aorta in the control cases (71.8 {+-} 11{sup o}). In 12 patients, slow flow was detected in the RCA. Those with slow flow in the RCA had significantly smaller angles (mean: 33.2 {+-} 20.4{sup o}) than the other cases (mean: 78.9 {+-} 10.7{sup o}). Conclusion: A small angle of origin of the main coronary arteries from the aorta, measured on MDCT examinations is correlated with slow blood flow in those vessels, as calculated by the TIMI frame count in catheter coronary angiography.

  7. Normal left ventricular emptying in coronary artery disease at rest: analysis by radiographic and equilibrium radionuclide ventriculography

    International Nuclear Information System (INIS)

    Denenberg, B.S.; Makler, P.T.; Bove, A.A.; Spann, J.F.

    1981-01-01

    The volume ejected early in systole has been proposed as an indicator of abnormal left ventricular function that is present at rest in patients with coronary artery disease with a normal ejection fraction and normal wall motion. The volume ejected in systole was examined by calculating the percent change in ventricular volume using both computer-assisted analysis of biplane radiographic ventriculograms at 60 frames/s and equilibrium gated radionuclide ventriculograms. Ventricular emptying was examined with radiographic ventriculography in 33 normal patients and 23 patients with coronary artery disease and normal ejection fraction. Eight normal subjects and six patients with coronary artery disease had both radiographic ventriculography and equilibrium gated radionuclide ventriculography. In all patients, there was excellent correlation between the radiographic and radionuclide ventricular emptying curves (r . 0.971). There were no difference in the ventricular emptying curves of normal subjects and patients with coronary artery disease whether volumes were measured by radiographic or equilibrium gated radionuclide ventriculography. It is concluded that the resting ventricular emptying curves are identical in normal subjects and patients with coronary artery disease who have a normal ejection fraction and normal wall motion

  8. Determinants and Outcomes of Stroke Following Percutaneous Coronary Intervention by Indication.

    Science.gov (United States)

    Myint, Phyo Kyaw; Kwok, Chun Shing; Roffe, Christine; Kontopantelis, Evangelos; Zaman, Azfar; Berry, Colin; Ludman, Peter F; de Belder, Mark A; Mamas, Mamas A

    2016-06-01

    Stroke after percutaneous coronary intervention (PCI) is a serious complication, but its determinants and outcomes after PCI in different clinical settings are poorly documented. The British Cardiovascular Intervention Society (BCIS) database was used to study 560 439 patients who underwent PCI in England and Wales between 2006 and 2013. We examined procedural-type specific determinants of ischemic and hemorrhagic stroke and the likelihood of subsequent 30-day mortality and in-hospital major adverse cardiovascular events (a composite of in-hospital mortality, myocardial infarction or reinfarction, and repeat revascularization). A total of 705 stroke cases were recorded (80% ischemic). Stroke after an elective PCI or PCI for acute coronary syndrome indications was associated with a higher risk of adverse outcomes compared with those without stroke; 30-day mortality and major adverse cardiovascular events outcomes in fully adjusted model were odds ratios 37.90 (21.43-67.05) and 21.05 (13.25-33.44) for elective and 5.00 (3.96-6.31) and 6.25 (5.03-7.77) for acute coronary syndrome, respectively. Comparison of odds of these outcomes between these 2 settings showed no differences; corresponding odds ratios were 1.24 (0.64-2.43) and 0.63 (0.35-1.15), respectively. Hemorrhagic and ischemic stroke complications are uncommon, but serious complications can occur after PCI and are independently associated with worse mortality and major adverse cardiovascular events outcomes in both the elective and acute coronary syndrome setting irrespective of stroke type. Our study provides a better understanding of the risk factors and prognosis of stroke after PCI by procedure type, allowing physicians to provide more informed advice around stroke risk after PCI and counsel patients and their families around outcomes if such neurological complications occur. © 2016 American Heart Association, Inc.

  9. Percutaneous brachial artery catheterization for coronary angiography and percutaneous coronary interventions (pci): an encouraging experience of 100 cases

    International Nuclear Information System (INIS)

    Islam, Z.U.; Maken, G.R.; Saif, M.; Khattak, Z.A.

    2013-01-01

    Objective: To evaluate the practicability and safety of the percutaneous transbrachial approach (TBA) for diagnostic coronary angiography and therapeutic percutaneous coronary interventions. Study Design: Quasi experimental study. Place and Duration of Study: The study was carried out in Armed Forces Institute of Cardiology- National Institute of Heart Diseases (AFIC-NIHD) from March 2009 to May 2011. Patients and Methods: We collected data of 100 consecutive patients who underwent coronary catheterization by the percutaneous transbrachial approach. Transbrachial catheterization was performed only if the radial access failed or radial pulse was feeble. Study endpoints included successful brachial artery catheterization, vascular and neurological complications at access site and procedure success rate. Results: Mean age of the patients was 54 years (range 33-79 yrs) and 65(65%) were males and 35 (35%) were females. The right brachial artery was used in all of the cases. Procedural success was achieved in 100% of the patients. Coronary angiography was performed in 70 patients and percutaneous coronary interventions were done in 30 cases. Out of these 30 cases, PCI to left coronary arteries (LAD and LCX) were performed in 19 patients while 11 patients had PCI to right coronary artery (RCA). No case of vascular complications such as major access site bleeding, vascular perforation, brachial artery occlusion causing forearm ischemia, compartment syndrome, vascular spasm or failure to catheterize coronary arteries requiring alternate vascular access were observed. Conclusion: Brachial artery is a safe and easily accessible approach for coronary angiography and percutaneous coronary interventions. (author)

  10. The Relationship of Body Composition and Coronary Artery Calcification in Apparently Healthy Korean Adults

    Directory of Open Access Journals (Sweden)

    Jung-Hee Yu

    2013-03-01

    Full Text Available BackgroundWe investigated the association of coronary artery calcium score (CACS with body composition and insulin resistance in apparently healthy Korean adults.MethodsNine hundred forty-five participants (mean age, 48.9 years; 628 men in a medical check-up program were selected for analysis. Body composition was assessed by bioelectrical impedance analysis (BIA. Insulin resistance was evaluated using the homeostasis model assessment of insulin resistance (HOMA-IR. The CACS was assessed by multidetector computed tomography.ResultsOne hundred forty-six subjects (15.4% showed coronary artery calcification and 148 subjects (15.7% had metabolic syndrome. CACS showed a significant positive correlation with age, fasting glucose level, waist circumference (WC, blood pressure, hemoglobin A1c, HOMA-IR, and waist-hip ratio (WHR assessed by BIA. CACS had a negative correlation with high density lipoprotein cholesterol (HDL-C. Subjects with high CACS showed significantly higher mean WHRs and lower mean values for lean body mass compared with subjects without coronary artery calcification. In logistic regression analyses with coronary artery calcification as the dependent variable, the highest quartile of WHR showed a 3.125-fold increased odds ratio for coronary artery calcification compared with the lowest quartile after adjustment for confounding variables. When receiver operating characteristics analyses were performed with coronary artery calcification as the result variable, WHR showed the largest area under the curve (AUC value among other variables except for age and WC in women (AUC=0.696 for WHR, 0.790 for age, and 0.719 for WC in women.ConclusionIn our study population of apparently healthy Korean adults, WHR was the most significant predictor for coronary artery calcification among other confounding factors, suggesting that it may have implication as a marker for early atherosclerosis.

  11. Online Angiography Image-Based FFR Assessment During Coronary Catheterization: A Single-Center Study.

    Science.gov (United States)

    Kornowski, Ran; Vaknin-Assa, Hana; Assali, Abid; Greenberg, Gabriel; Valtzer, Orna; Lavi, Ifat

    2018-03-15

    To assess the diagnostic performance of angiography-derived fractional flow reserve (FFRangio) measurements in patients with stable coronary artery disease when used online in the catheterization laboratory during routine coronary angiography. FFR, an index of the hemodynamic severity of coronary stenosis, is derived from invasive measurements using a pressure-monitoring guidewire and hyperemic stimulus. While FFR is the gold standard, it remains under-utilized. FFRangio may have several advantages owing to the reduced operator time, no wire-related or procedural complications, and no need for administration of vasodilators. FFRangio is a novel technology that uses a patient's hemodynamic data and routine angiograms to generate FFR values at each point along the coronary tree. We present the online application of the system where FFRangio was successfully used in the catheterization laboratory during routine coronary angiography and compared to invasive FFR. Fifty-three patients (79% men) and 60 coronary lesions were analyzed. Values derived using FFRangio ranged from 0.58-0.96 and correlated closely (Pearson's correlation coefficient, r=0.91; Psystem. In this single-center experience, FFRangio values showed high correlation rates to invasive FFR.

  12. Congenital Absence of Left Circumflex Artery Detected by Computed Tomography Coronary Angiography: A Case Report

    Directory of Open Access Journals (Sweden)

    Keerati Hongsakul

    2012-01-01

    Full Text Available The congenital absence of the left circumflex artery (LCx is a very rare congenital anomaly of coronary arteries, but it is benign. Currently, the best modality for the diagnosis of coronary anomalies is computed tomography coronary angiography (CTCA. We report a case of congenitally absent LCx with an atypical chest pain.

  13. Transesophageal echocardiography in the assessment of coronary arteries

    International Nuclear Information System (INIS)

    Adamek-Kosmider, A.; Kasprzak, J.; Kosmider, M.; Krzeminska-Pakula, M.

    1993-01-01

    The study was undertaken to assess the usefulness of TEE for evaluation of morphology and flow in coronary arteries. TEE (2D, spectral and color Doppler imaging) and coronary angiography were performed in 75 patients - 41 with valvular heart disease and 34 with ischemic heart disease. Proximal coronary artery stenosis was detected by coronarography in 11 pts (9-left main coronary artery, 2-right coronary artery). TEE visualization of proximal coronary arteries was possible in all pts. Echocardiographic features of artery stenosis were: the narrowing of the vessel in 2D image (9 pts), high flow velocity spectral Doppler (4 pts, mean 135 cm/s vs 55 cm/s in normal arteries) and mosaic, turbulent flow in color Doppler (10 pts). Sensitivity and specificity of TEE for coronary artery stenosis detection was respectively 81%/98% for 2D imaging and 90%/100% for color Doppler. TEE is a new, noninvasive and safe method for the evaluation of proximal coronary arteries. Detection of LMCA stenosis prior to atheterization may enhance the safety of coronary angiography. (author)

  14. All-optical OFDM demultiplexing by spectral magnification and optical band-pass filtering

    DEFF Research Database (Denmark)

    Palushani, Evarist; Mulvad, Hans Christian Hansen; Kong, Deming

    2013-01-01

    We propose spectral magnification of optical-OFDM super-channels using time-lenses, enabling reduced inter-carrier-interference in subcarrier detection by simple band-pass filtering. A demonstration on an emulated 100 Gbit/s DPSK optical-OFDM channel shows improved sensitivities after 4-times spe...

  15. High ratio of triglycerides to hdl-cholesterol predicts extensive coronary disease

    Directory of Open Access Journals (Sweden)

    Protasio Lemos da Luz

    2008-01-01

    Full Text Available An abnormal ratio of triglycerides to HDL-cholesterol (TG/HDL-c indicates an atherogenic lipid profile and a risk for the development of coronary disease. OBJECTIVE: To investigate the association between lipid levels, specifically TG/HDL-c, and the extent of coronary disease. METHODS: High-risk patients (n = 374 submitted for coronary angiography had their lipid variables measured and coronary disease extent scored by the Friesinger index. RESULTS: The subjects consisted of 220 males and 154 females, age 57.2 ± 11.1 years, with total cholesterol of 210± 50.3 mg/dL, triglycerides of 173.8 ± 169.8 mg/dL, HDL-cholesterol (HDL-c of 40.1 ± 12.8 mg/dL, LDL-cholesterol (LDL-c of 137.3 ± 46.2 mg/dL, TG/HDL-c of 5.1 ± 5.3, and a Friesinger index of 6.6 ± 4.7. The relationship between the extent of coronary disease (dichotomized by a Friesenger index of 5 and lipid levels (normal vs. abnormal was statistically significant for the following: triglycerides, odds ratio of 2.02 (1.31-3.1; p = 0.0018; HDL-c, odds ratio of 2.21 (1.42-3.43; p = 0.0005; and TG/HDL-c, odds ratio of 2.01(1.30-3.09; p = 0.0018. However, the relationship was not significant between extent of coronary disease and total cholesterol [1.25 (0.82-1.91; p = 0.33] or LDL-c [1.47 (0.96-2.25; p = 0.0842]. The chi-square for linear trends for Friesinger > 4 and lipid quartiles was statistically significant for triglycerides (p = 0.0017, HDL-c (p = 0.0001, and TG/HDL-c (p = 0.0018, but not for total cholesterol (p = 0.393 or LDL-c (p = 0.0568. The multivariate analysis by logistic regression OR gave 1.3 ± 0.79 (p = .0001 for TG/HDL-c, 0.779 ± 0.074 (p = .0001 for HDL-c, and 1.234 ± 0.097 (p = 0.03 for LDL. Analysis of receiver operating characteristic curves showed that only TG/HDL-c and HDL-c were useful for detecting extensive coronary disease, with the former more strongly associated with disease. CONCLUSIONS: Although some lipid variables were associated with the extent of

  16. Advanced 2-dimensional quantitative coronary angiographic analysis for prediction of fractional flow reserve in intermediate coronary stenoses.

    Science.gov (United States)

    Opolski, Maksymilian P; Pregowski, Jerzy; Kruk, Mariusz; Kepka, Cezary; Staruch, Adam D; Witkowski, Adam

    2014-07-01

    The widespread clinical application of coronary computed tomography angiography (CCTA) has resulted in increased referral patterns of patients with intermediate coronary stenoses to invasive coronary angiography. We evaluated the application of advanced quantitative coronary angiography (A-QCA) for predicting fractional flow reserve (FFR) in intermediate coronary lesions detected on CCTA. Fifty-six patients with 66 single intermediate coronary lesions (≥ 50% to 80% stenosis) on CCTA prospectively underwent coronary angiography and FFR. A-QCA including calculation of the Poiseuille-based index defined as the ratio of lesion length to the fourth power of the minimal lumen diameter (MLD) was performed. Significant stenosis was defined as FFR ≤ 0.80. The mean FFR was 0.86 ± 0.09, and 18 lesions (27%) were functionally significant. FFR correlated with lesion length (R=-0.303, P=0.013), MLD (R=0.527, P44%, and >69%, respectively (maximum negative predictive value of 94% for MLA, maximum positive predictive value of 58% for diameter stenosis). The Poiseuille-based index was the most accurate (C statistic 0.86, sensitivity 100%, specificity 71%, positive predictive value 56%, and negative predictive value 100%) predictor of FFR ≤ 0.80, but showed the lowest interobserver agreement (intraclass correlation coefficient 0.37). A-QCA might be used to rule out significant ischemia in intermediate stenoses detected by CCTA. The diagnostic application of the Poiseuille-based angiographic index is precluded by its high interobserver variability.

  17. Impact of coronary dominance on in-hospital outcomes after percutaneous coronary intervention in patients with acute coronary syndrome.

    Directory of Open Access Journals (Sweden)

    Toshiki Kuno

    Full Text Available OBJECTIVE: This study evaluated the manner in which coronary dominance affects in-hospital outcomes of acute coronary syndrome (ACS patients undergoing percutaneous coronary intervention (PCI. BACKGROUND: Previous studies have shown that left dominant coronary anatomies are associated with worse prognoses in patients with coronary artery disease. METHODS: Data were analyzed from 4873 ACS patients undergoing PCI between September 2008 and April 2013 at 14 hospitals participating in the Japanese Cardiovascular Database Registry. The patients were grouped based on diagnostic coronary angiograms performed prior to PCI; those with right- or co-dominant anatomy (RD group and those with left-dominant anatomy (LD group. RESULTS: The average patient age was 67.6±11.8 years and both patient groups had similar ages, coronary risk factors, comorbidities, and prior histories. The numbers of patients presenting with symptoms of heart failure, cardiogenic shock, or cardiopulmonary arrest were significantly higher in the LD group than in the RD group (heart failure: 650 RD patients [14.7%] vs. 87 LD patients [18.8%], P = 0.025; cardiogenic shock: 322 RD patients [7.3%] vs. 48 LD patients [10.3%], P = 0.021; and cardiopulmonary arrest: 197 RD patients [4.5%] vs. 36 LD patients [7.8%], P = 0.003. In-hospital mortality was significantly higher among LD patients than among RD patients (182 RD patients [4.1%] vs. 36 LD patients [7.8%], P = 0.001. Multivariate logistic regression analysis revealed that LD anatomy was an independent predictor for in-hospital mortality (odds ratio, 1.75; 95% confidence interval, 1.06-2.89; P = 0.030. CONCLUSION: Among ACS patients who underwent PCI, LD patients had significantly worse in-hospital outcomes compared with RD patients, and LD anatomy was an independent predictor of in-hospital mortality.

  18. [Endarterectomy of the coronary arteries].

    Science.gov (United States)

    Fischer, V; Simkovic, I; Holoman, M; Verchvodko, P; Janotík, P; Galbánek, J; Hulman, M; Kostelnicák, J; Jurco, R; Slezák, J

    1992-02-01

    The authors analyze 50 patients with endarterectomy of the coronary arteries during the periods of 1972-1974 and 1988-1990. The results of endarterectomy of the right and left coronary artery provide evidence of its justification in indicated cases whereby contrary to some departments the results of endarterectomy of the left coronary artery are comparable with endarterectomy of the right coronary artery.

  19. [Leisure-time sport activities and cardiac outpatient therapy in coronary patients].

    Science.gov (United States)

    Heitkamp, Hans-Christian; Schimpf, Thomas M; Hipp, Arno; Niess, Andreas

    2005-03-01

    Exercise intensity in coronary patients is controlled by heart rate measurements. Very few investigations have compared the maximum heart rate in cardiac outpatient groups, in leisure-time sport activities, and especially in swimming. Within different exercise conditions 21 coronary patients, nine in well-compensated cardiac condition joining a training group and twelve joining the exercise group with lower intensity, without signs of heart failure, engaged in an incremental bicycle ergometry. A six-lead ECG was derived at the same time with a 24-h ECG. The performance tolerance was measured by the pulse limit derived in 20 patients; one patient failed to show signs of subjective or objective ischemia. During a 24-h ECG monitoring, the patients took part in a 1-h standardized cardiac outpatient program, a standardized swimming program 4 x 25 m, and a typical self-selected leisure-time activity. The patients showed a peak work capacity of 2.2 W/kg and a symptom-free work capacity of 1.3 W/kg. The derived upper heart rate limit was passed during swimming by 19, during leisure-time activity by 16, and during cardiac outpatient program by two patients. The maximum of the mean overriding the limit occurred in leisure-time activity. Signs of ischemia occurred during ergometry in 15, during swimming training in ten patients, during leisure-time activity in eight, and during cardiac outpatient therapy in one. Arrhythmia leisure-time sport activity in 15, during cardiac outpatient therapy in 17, and during swimming in eight patients. Arrhythmia Lown IVa occurred in one patient each during ergometry, leisure sports, and during the night. Coronary patients are in danger to exercise beyond the pulse limit during swimming and other leisure-time sports and not during cardiac outpatient therapy. The upper heart rate limit should be observed during swimming and other endurance leisure-time activities, and is of little importance during cardiac outpatient therapy.

  20. Topographic association of angioscopic yellow plaques with coronary atherosclerotic plaque: assessment with quantitative colorimetry in human coronary artery autopsy specimens.

    Science.gov (United States)

    Ishibashi, Fumiyuki; Lisauskas, Jennifer B; Kawamura, Akio; Waxman, Sergio

    2008-01-01

    Yellow plaques seen during coronary angioscopy are thought to be the surrogates for superficial intimal lipids in coronary plaque. Given diffuse and heterogeneous nature of atherosclerosis, yellow plaques in coronaries may be seen as several yellow spots on diffuse coronary plaque. We examined the topographic association of yellow plaques with coronary plaque. In 40 non-severely stenotic ex-vivo coronary segments (average length: 52.2 +/- 3.1 mm), yellow plaques were examined by angioscopy with quantitative colorimetry. The segments were cut perpendicular to the long axis of the vessel at 2 mm intervals, and 1045 slides with 5 microm thick tissue for whole segments were prepared. To construct the plaque surface, each tissue slice was considered to be representative of the adjacent 2 mm. The circumference of the lumen and the lumen border of plaque were measured in each slide, and the plaque surface region was constructed. Coronary plaque was in 37 (93%) of 40 segments, and consisted of a single mass [39.9 +/- 3.9 (0-100) mm, 311.3 +/- 47.4 (0.0-1336.2) mm2]. In 30 (75%) segments, multiple (2-9) yellow plaques were detected on a mass of coronary plaque. The number of yellow plaques correlated positively with coronary plaque surface area (r = 0.77, P colorimetry, some of them are associated with lipid cores underneath thin fibrous caps, may be used to assess the extent of coronary plaque. Further research using angioscopy could be of value to study the association of high-risk coronaries with acute coronary syndromes.

  1. Coronary artery bypass surgery in the diabetic patient.

    LENUS (Irish Health Repository)

    Maher, M

    2012-02-03

    Coronary artery and peripheral occlusive arterial disease frequently complicate diabetes mellitus, with death due to atherosclerotic coronary artery disease being three times more likely in diabetic compared to non-diabetic patients. The profile of 32 diabetic patients and 32 matched controls who underwent coronary artery bypass (CABG) is studied and their early and late postoperative outcomes are described. The mean age was 61 +\\/- 1 year in both groups. The diabetic group comprised 26 non-insulin dependent and 6 insulin dependent diabetics, who had a mean duration of diabetes of 8.5 years (range 2 months--35 years). The median number of grafts per patient performed in the diabetic group and the control group was 3.5 and 3 respectively. There was no mortality in the series, however considerably greater wound morbidity rates were encountered in the diabetic group when compared to matched controls. One renal transplant patient in the diabetic group suffered irreversible acute tubular necrosis and became dialysis dependent post-operatively. Longterm follow-up showed no longterm mortality in either group, with full relief of angina achieved in 75% of diabetic patients compared with 87.5% of matched controls. In addition diabetic patients suffered greater longterm cardiac morbidity than the control group (21.8% versus 12.5%). The results of this study suggest that CABG is a safe operation for the diabetic patient. Diabetic patients receive satisfactory symptomatic relief of angina, but suffer increased perioperative wound complications and greater incidence of longterm cardiac morbidity.

  2. Detection of coronary calcium with electron beam tomography in coronary artery disease

    International Nuclear Information System (INIS)

    Haberl, R.; Knez, A.; Becker, A.; Becker, C.; Bruening, R.; Reiser, M.; Maass, A.; Steinbeck, G.

    1998-01-01

    Purpose: Coronary calcium is a powerful indicator of arteriosclerosis and can be detected very precisely with electron beam tomography. The method can be applied in patients with known coronary artery disease or in asymptomatic patients at risk of arteriosclerotic disease. Results: At the University of Munich we performed an EBT scan of the heart in 1100 patients within the last year. In 567 patients coronary angiography was performed also (±3 days). Confirming previous reports in the literature, we found a correlation of the calcium score with the age and gender of the patients. Severe coronary artery disease (stenoses ≥ 75%) was associated with significantly more calcium than less severe CAD. The calcium score did not discriminate between one-, two- and three-vessel disease. The site of calcification does not correlate with the localization of stenoses. Thirty-three percent of the patients with significant coronary artery disease showed a normal age-adjusted calcium score; a total of 8.1% of patients with severe stenoses did not reveal any coronary calcification (score =0). With asymptomatic patients there are only a few studies available. Soft plaques cannot be detected with EBT, but in most patients soft plaques occur together with hard plaques. Our results show that spiral CT of the newest generation may also be used for calcium screening. There was an excellent correlation of the calcium scores of EBT and spiral CT at all levels of calcification. Discussion: Coronary calcium is a sensitive marker of coronary artery disease. In the clinical setting EBT is indicated in patients with known coronary artery disease (to evaluate prognosis), in patients who are unable to perform a stress test, and in patients with atypical chest pain. However, lack of calcification may be associated with severe stenoses in a minority of patients. The clinical value in asymptomatic patients needs to be defined: Randomized studies are necessary. We see a possible indication in

  3. Computed tomography angiography and perfusion to assess coronary artery stenosis causing perfusion defects by single photon emission computed tomography

    DEFF Research Database (Denmark)

    Rochitte, Carlos E; George, Richard T; Chen, Marcus Y

    2014-01-01

    AIMS: To evaluate the diagnostic power of integrating the results of computed tomography angiography (CTA) and CT myocardial perfusion (CTP) to identify coronary artery disease (CAD) defined as a flow limiting coronary artery stenosis causing a perfusion defect by single photon emission computed...... emission computed tomography (SPECT/MPI). Sixteen centres enroled 381 patients who underwent combined CTA-CTP and SPECT/MPI prior to conventional coronary angiography. All four image modalities were analysed in blinded independent core laboratories. The prevalence of obstructive CAD defined by combined ICA...... tomography (SPECT). METHODS AND RESULTS: We conducted a multicentre study to evaluate the accuracy of integrated CTA-CTP for the identification of patients with flow-limiting CAD defined by ≥50% stenosis by invasive coronary angiography (ICA) with a corresponding perfusion deficit on stress single photon...

  4. Characterization of gut microbiota profiles in coronary artery disease patients using data mining analysis of terminal restriction fragment length polymorphism: gut microbiota could be a diagnostic marker of coronary artery disease.

    Science.gov (United States)

    Emoto, Takuo; Yamashita, Tomoya; Kobayashi, Toshio; Sasaki, Naoto; Hirota, Yushi; Hayashi, Tomohiro; So, Anna; Kasahara, Kazuyuki; Yodoi, Keiko; Matsumoto, Takuya; Mizoguchi, Taiji; Ogawa, Wataru; Hirata, Ken-Ichi

    2017-01-01

    The association between atherosclerosis and gut microbiota has been attracting increased attention. We previously demonstrated a possible link between gut microbiota and coronary artery disease. Our aim of this study was to clarify the gut microbiota profiles in coronary artery disease patients using data mining analysis of terminal restriction fragment length polymorphism (T-RFLP). This study included 39 coronary artery disease (CAD) patients and 30 age- and sex- matched no-CAD controls (Ctrls) with coronary risk factors. Bacterial DNA was extracted from their fecal samples and analyzed by T-RFLP and data mining analysis using the classification and regression algorithm. Five additional CAD patients were newly recruited to confirm the reliability of this analysis. Data mining analysis could divide the composition of gut microbiota into 2 characteristic nodes. The CAD group was classified into 4 CAD pattern nodes (35/39 = 90 %), while the Ctrl group was classified into 3 Ctrl pattern nodes (28/30 = 93 %). Five additional CAD samples were applied to the same dividing model, which could validate the accuracy to predict the risk of CAD by data mining analysis. We could demonstrate that operational taxonomic unit 853 (OTU853), OTU657, and OTU990 were determined important both by the data mining method and by the usual statistical comparison. We classified the gut microbiota profiles in coronary artery disease patients using data mining analysis of T-RFLP data and demonstrated the possibility that gut microbiota is a diagnostic marker of suffering from CAD.

  5. Measurement of flow by-passing and turbulent mixing in a model of a fast-reactor steam generator

    International Nuclear Information System (INIS)

    Little, A.J.; Fallows, T.; Central Electricity Generating Board, Leatherhead

    1989-01-01

    A description is given of measurements of edge by-pass velocities and turbulent mixing in a model of a fast reactor steam generator. The velocity measurements were carried out using a DANTEC triple-split fibre probe which allowed both the speed and flow angle of a velocity vector to be measured in a plane normal to the axis of the probe. The measurements revealed the presence of reverse flows in the by-pass and adjacent in-bank channels downstream of a grid plate. The magnitude of the by-pass flow was reduced considerably by the insertion of a kicker grid at the mid point between grid plates. Turbulent mixing measurements revealed that circumferential mixing in channels near the by-pass channel was up to 5 times greater than the radial mixing. The level of radial mixing at the edge of the bank was similar to that measured near the centre of the bank. A method of transposing mass diffusion measurements in air to thermal diffusivities of sodium is discussed. (orig.)

  6. Determining the proportion of coronary segments assessable on 16-slice CT coronary angiography: a brief report

    International Nuclear Information System (INIS)

    Soon, K. H.; Cox, N.; Eccleston, D.; Lim, Y.; Chaitowitz, I.; Bell, K. W.; Kelly, A-M.

    2007-01-01

    Computed tomography coronary angiography (CT-CA) is becoming a popular non-invasive coronary imaging method. We aimed to determine the proportion of coronary segments assessable on a 16-slice CT in comparison with conventional selective coronary angiography (SCA). We identified all patients who had both 16-slice CT-CA and recent SCA (less than 12 months) from March 2004 to July 2005. Two CT reporters blinded to SCA independently classified coronary segment assessability on CT-CA. A cardiologist blinded to CT findings classified assess-ability of coronary segments on SCA. Data were analysed using descriptive statistics and proportion of agreement. Ninety-five study pairs were included in the analysis. Of those, 1161 coronary segments were deemed assessable on SCA and 1103 segments (95%) were also assessable on CT-CA. Nonassessable segments on CT-CA were predominantly in the distal segments and branches of coronary arteries. Reasons for nonassessability were small calibre (48.3%), motion artefacts (20.7%) and poorly reconstructed segments (22.4%). The 16-slice CT was able to assess a high proportion of but not all coronary segments. Nonassessable segments were predominantly distal segments or branches of coronary arteries. Motion artefacts due to heart-rate changes, small calibre and poorly reconstructed images were main causes of nonassessability on 16-slice CT-CA

  7. Blooming Artifact Reduction in Coronary Artery Calcification by A New De-blooming Algorithm: Initial Study.

    Science.gov (United States)

    Li, Ping; Xu, Lei; Yang, Lin; Wang, Rui; Hsieh, Jiang; Sun, Zhonghua; Fan, Zhanming; Leipsic, Jonathon A

    2018-05-02

    The aim of this study was to investigate the use of de-blooming algorithm in coronary CT angiography (CCTA) for optimal evaluation of calcified plaques. Calcified plaques were simulated on a coronary vessel phantom and a cardiac motion phantom. Two convolution kernels, standard (STND) and high-definition standard (HD STND), were used for imaging reconstruction. A dedicated de-blooming algorithm was used for imaging processing. We found a smaller bias towards measurement of stenosis using the de-blooming algorithm (STND: bias 24.6% vs 15.0%, range 10.2% to 39.0% vs 4.0% to 25.9%; HD STND: bias 17.9% vs 11.0%, range 8.9% to 30.6% vs 0.5% to 21.5%). With use of de-blooming algorithm, specificity for diagnosing significant stenosis increased from 45.8% to 75.0% (STND), from 62.5% to 83.3% (HD STND); while positive predictive value (PPV) increased from 69.8% to 83.3% (STND), from 76.9% to 88.2% (HD STND). In the patient group, reduction in calcification volume was 48.1 ± 10.3%, reduction in coronary diameter stenosis over calcified plaque was 52.4 ± 24.2%. Our results suggest that the novel de-blooming algorithm could effectively decrease the blooming artifacts caused by coronary calcified plaques, and consequently improve diagnostic accuracy of CCTA in assessing coronary stenosis.

  8. Relationship of Hypertension to Coronary Atherosclerosis and Cardiac Events in Patients With Coronary Computed Tomographic Angiography.

    Science.gov (United States)

    Nakanishi, Rine; Baskaran, Lohendran; Gransar, Heidi; Budoff, Matthew J; Achenbach, Stephan; Al-Mallah, Mouaz; Cademartiri, Filippo; Callister, Tracy Q; Chang, Hyuk-Jae; Chinnaiyan, Kavitha; Chow, Benjamin J W; DeLago, Augustin; Hadamitzky, Martin; Hausleiter, Joerg; Cury, Ricardo; Feuchtner, Gudrun; Kim, Yong-Jin; Leipsic, Jonathon; Kaufmann, Philipp A; Maffei, Erica; Raff, Gilbert; Shaw, Leslee J; Villines, Todd C; Dunning, Allison; Marques, Hugo; Pontone, Gianluca; Andreini, Daniele; Rubinshtein, Ronen; Bax, Jeroen; Jones, Erica; Hindoyan, Niree; Gomez, Millie; Lin, Fay Y; Min, James K; Berman, Daniel S

    2017-08-01

    Hypertension is an atherosclerosis factor and is associated with cardiovascular risk. We investigated the relationship between hypertension and the presence, extent, and severity of coronary atherosclerosis in coronary computed tomographic angiography and cardiac events risk. Of 17 181 patients enrolled in the CONFIRM registry (Coronary CT Angiography Evaluation for Clinical Outcomes: An International Multicenter Registry) who underwent ≥64-detector row coronary computed tomographic angiography, we identified 14 803 patients without known coronary artery disease. Of these, 1434 hypertensive patients were matched to 1434 patients without hypertension. Major adverse cardiac events risk of hypertension and non-hypertensive patients was evaluated with Cox proportional hazards models. The prognostic associations between hypertension and no-hypertension with increasing degree of coronary stenosis severity (nonobstructive or obstructive ≥50%) and extent of coronary artery disease (segment involvement score of 1-5, >5) was also assessed. Hypertension patients less commonly had no coronary atherosclerosis and more commonly had nonobstructive and 1-, 2-, and 3-vessel disease than the no-hypertension group. During a mean follow-up of 5.2±1.2 years, 180 patients experienced cardiac events, with 104 (2.0%) occurring in the hypertension group and 76 (1.5%) occurring in the no-hypertension group (hazard ratios, 1.4; 95% confidence intervals, 1.0-1.9). Compared with no-hypertension patients without coronary atherosclerosis, hypertension patients with no coronary atherosclerosis and obstructive coronary disease tended to have higher risk of cardiac events. Similar trends were observed with respect to extent of coronary artery disease. Compared with no-hypertension patients, hypertensive patients have increased presence, extent, and severity of coronary atherosclerosis and tend to have an increase in major adverse cardiac events. © 2017 American Heart Association, Inc.

  9. Vehicle dynamic effects in the course of passing over turnouts

    Directory of Open Access Journals (Sweden)

    Zelenka J.

    2007-11-01

    Full Text Available For the quantification of vehicle dynamic effects at passing over turnouts at a higher speed there was developed a methodology for evaluating of acceleration measured on vehicle axle boxes in the year 2003. The methodology is based on statistical evaluation of lateral and vertical acceleration measured values at passing over both critical parts of a turnout (tongue, frog. The created methodology was used for investigation of vehicle dynamic effects by running at speed up to 230 km/h in the year 2004 in terms of high speed tests of tilting-body unit class 680 CD. There was found relatively high values of dynamic effects already at a speed 160 km/h. In terms of tilting-body unit class 680 tests at a higher speed in curves of chosen track lines of 1st and 2nd corridor of Czech Railways there was carried out also verification of curved turnouts state according to methodology mentioned above with a view to possibility of speed increasing at curved throats of chosen stations. Lateral vehicle dynamic effects at passing over a curved turnout frog area were evaluated. There were carried out simulation calculations of vehicle passing over a turnout based on measured geometric parameters of wheelset as well as chosen turnouts. Results of the calculations were compared with measurements. The increased vehicle dynamic effects found in pulsed beats character influence negatively the turnouts part (not only wheel contacting parts as well as operating life all unsuspended parts of vehicles.

  10. Coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Dewey, Marc [Charite - Universitaetsmedizin Berlin (Germany). Inst. fuer Radiologie

    2009-07-01

    Coronary CT angiography has attained increasing scientific attention at academic institutions and has become a highly accurate diagnostic modality. Extending this knowledge into a practice setting is the purpose of 'Coronary CT Angiography'. This book will assist you in integrating cardiac CT into your daily practice, while also giving an overview of the current technical status and applications. The specific features of scanners from all four main vendors are also presented providing an objective overview of noninvasive coronary angiography using CT. (orig.)

  11. Coffee consumption and coronary calcification: The Rotterdam coronary calcification study

    NARCIS (Netherlands)

    G.J. van Woudenbergh (Geertruida); R. Vliegenthart (Rozemarijn); F.J.A. van Rooij (Frank); A. Hofman (Albert); M. Oudkerk (Matthijs); J.C.M. Witteman (Jacqueline); J.M. Geleijnse (Marianne)

    2008-01-01

    textabstractBACKGROUND - The role of coffee in the cardiovascular system is not yet clear. We examined the relation of coffee intake with coronary calcification in a population-based cohort. METHODS AND RESULTS - The study involved 1570 older men and women without coronary heart disease who

  12. Determination of human coronary artery composition by Raman spectroscopy.

    Science.gov (United States)

    Brennan, J F; Römer, T J; Lees, R S; Tercyak, A M; Kramer, J R; Feld, M S

    1997-07-01

    We present a method for in situ chemical analysis of human coronary artery using near-infrared Raman spectroscopy. It is rapid and accurate and does not require tissue removal; small volumes, approximately 1 mm3, can be sampled. This methodology is likely to be useful as a tool for intravascular diagnosis of artery disease. Human coronary artery segments were obtained from nine explanted recipient hearts within 1 hour of heart transplantation. Minces from one or more segments were obtained through grinding in a mortar and pestle containing liquid nitrogen. Artery segments and minces were excited with 830 nm near-infrared light, and Raman spectra were collected with a specially designed spectrometer. A model was developed to analyze the spectra and quantify the amounts of cholesterol, cholesterol esters, triglycerides and phospholipids, and calcium salts present. The model provided excellent fits to spectra from the artery segments, indicating its applicability to intact tissue. In addition, the minces were assayed chemically for lipid and calcium salt content, and the results were compared. The relative weights obtained using the Raman technique agreed with those of the standard assays within a few percentage points. The chemical composition of coronary artery can be quantified accurately with Raman spectroscopy. This opens the possibility of using histochemical analysis to predict acute events such as plaque rupture, to follow the progression of disease, and to select appropriate therapeutic interventions.

  13. Clopidogrel administration prior to coronary artery bypass grafting surgery: the cardiologist's panacea or the surgeon's headache?

    Science.gov (United States)

    Kapetanakis, Emmanouil I; Medlam, Diego A; Boyce, Steven W; Haile, Elizabeth; Hill, Peter C; Dullum, Mercedes K C; Bafi, Ammar S; Petro, Kathleen R; Corso, Paul J

    2005-03-01

    Thrombotic complications after percutaneous coronary intervention procedures have decreased in past years mainly due to the use of clopidogrel antiplatelet therapy. However, the risk of bleeding due to enhanced and irreversible platelet inhibition in patients who will require surgical coronary revascularization instead has not been adequately addressed in the literature. The purpose of this study was to evaluate the effect of pre-operative clopidrogel exposure in haemorrhage-related re-exploration rates, peri-operative transfusion requirements, morbidity, and mortality in patients undergoing coronary artery bypass grafting (CABG) surgery. A study population of 2359 patients undergoing isolated CABG between January 2000 and June 2002 was reviewed. Of these, 415 (17.6%) received clopidogrel prior to CABG surgery, and 1944 (82.4%) did not. A risk-adjusted logistic regression analysis was used to assess the association between clopidogrel pre-medication (vs. no) and haemostatic re-operation, intraoperative and post-operative blood transfusion rates, and multiple transfusions received. Haemorrhage-related pre-operative risk factors identified from the literature and those found significant in a univariate model were used. Furthermore, a sub-cohort, matched-pair by propensity scores analysis, was also conducted. The clopidogrel group had a higher likelihood of haemostatic re-operation [OR = 4.9, (95% CI, 2.63-8.97), P < 0.01], an increase in total packed red blood cell transfusions [OR = 2.2, (95% CI, 1.70-2.84), P < 0.01], multiple unit blood transfusions [OR = 1.9, (95% CI, 1.33-2.75), P < 0.01] and platelet transfusions [OR = 2.6, (95% CI, 1.95-3.56), P < 0.01]. Surgical outcomes and operative mortality [OR = 1.5, (95% CI, 0.36-6.51), P = 0.56] were not significantly different. Pre-operative clopidogrel exposure increases the risk of haemostatic re-operation and the requirements for blood and blood product transfusion during, and after, CABG surgery.

  14. The relationship between fasting blood glucose variability and coronary artery collateral formation in type 2 diabetes patients with coronary artery disease.

    Science.gov (United States)

    Cheng, Gang; Mahmoudi, Hilda; Chokshi, Binna; Fernandez, Marlena; Kazemi, Vahid; Lamaa, Nader

    2017-09-01

    Coronary collaterals are an alternative source of blood supply to ischemic myocardium. Well-developed coronary collateral arteries in patients with coronary artery disease (CAD) limit the size of acute myocardial infarction and improves survival. The aim of this study was to investigate the relationship between glycemic variability and coronary collateral formation in patients with type 2 diabetes mellitus and CAD. Consecutive patients undergoing percutaneous coronary intervention or coronary artery bypass grafting procedures were studied. Multivariate logistic regression models were used to examine the association between coronary artery collateral formation graded by Rentrope classification and glycemic variability, measured by coefficient variation of fasting blood glucose. In our study, we retrospectively enrolled 300 patients, of whom 239 were diabetic (age: 70.1±11.9, 56% men) and 61 were nondiabetic (age: 71.5±11.5, 72% men). Diabetic patients were further stratified as follows: those with poor coronary collateral artery development (n=171, age: 69.7±12.4, 55% men) and those with good coronary collateral artery development (n=68, age 71.1±10.8, 59% men) according to the Rentrope classification. Our findings did not show association between glycemic variability and coronary collateral vessels development after controlling for potential confounders (odds ratio: 2.51; 95% confidence interval: 0.57-11.03; P=0.22). The culprit lesion (≥75% stenosis) in the left anterior descending artery and the right coronary artery was more frequent in the good collateral group compared with the poor collateral group (66 vs. 50%, P=0.02; 63 vs. 45%, P=0.01 respectively). Glycemic variability is not associated with coronary collateral artery formation in patients with type 2 diabetes mellitus and CAD.

  15. Coronary blood flow and coronary stenosis correlations in ischemic heart patients; Interventsionalni protseduri pod obrazen kontrol v usloviyata na dobolnichnata pomosht

    Energy Technology Data Exchange (ETDEWEB)

    Manukov, I [Plovdiv, (Bulgaria)

    2003-07-01

    The aim of the study is the assessment of the methodology for the C-TIMI frame count by Gibson for easy and fast determination of the coronary blood flow during a selective coronary angiography. 75 patient have been studied with one-branch affection of the coronary arteries. The criteria for exclusion are: myocardial hypertrophy, valve lesions, myocardial infarction and dyslipidemia. Depending of the characteristics of the coronary stenotic changes, the patients have been divided into two groups: 1) Patients with 'ordinary' stenosis of the coronary artery and 2) Patients with 'complex' stenosis. The severity of the stenotic changes in percents is the same for the two groups - 78%{+-}13% vs 81{+-}12%, respectively. In the first group a pronounced correlation is observed between the severity of the coronary stenosis and the slowing of the coronary blood flow. The 'threshold' stenotic level is 89%. In the second group the lowest value of the coronary stenosis is 73% (p>0.01 vs group 1). No correlation is observed between the severity of the coronary stenosis and the slowing of the coronary blood flow. A conclusion is made that the Gibson method for the assessment of the blood flow is convenient for the daily practice not only for the assessment of the significance of the coronary changes, but also for fast analysis of the achieved reconstruction of the coronary arteries after angioplasty. Additional studies of the significance of the different signs of 'complexity' of the coronary stenosis for the slowing of the blood flow are necessary.

  16. Assessment of PASS Effectiveness under Severe Accidents in Nuclear Power Plants

    International Nuclear Information System (INIS)

    Choi, Yu Jung; Lee, Sung Bok; Kim, Hyeong Taek; Lee, Jin Yong

    2008-01-01

    Following the accident at Three Mile Island Unit 2 (TMI-2) on March 28, 1979, the USNRC formed a lessons-learned Task Force to identify and evaluate safety concerns originating with the TMI-2 accident. NUREG-0578 documented the results of the task force effort. One of the recommendations of the task force was for licensees to upgrade the capability to obtain samples from the reactor coolant system and containment atmosphere under high radioactivity conditions and to provide the capability for chemical and spectral analyses of high-level samples on site. NUREG-0737 contained the details of the TMI recommendations that were to be implemented by the licensees. Additional criteria for post accident sampling system(PASS) were issued by Regulatory Guide 1.97. As the results, PASS has been installed on nuclear power plants(NPPs) in Korea as well as United States. However, significant improvements have been achieved since the TMI-2 accident in the areas of understanding risks associated with nuclear plant operations and developing better strategies for managing the response to potential severe accidents at NPPs. Thus, the requirements for PASS have been re-evaluated in some reports. According to the reports, the samples and measurements from PASS do not contribute significantly to emergency management response to severe accidents due to the long analyzing time, 3 hours. Hence, this paper focused on the development of the quantitative analysis methodology to analyze the sequence of the severe accident in Yonggwang nuclear power plants (YGN) and presented the results of the analysis according to the developed methodology

  17. Three-dimensional coronary MR angiography with continuous administration of Gd-DTPA. Delineation and detection of coronary artery stenosis

    International Nuclear Information System (INIS)

    Yokoyama, Kenichi

    1999-01-01

    Three-dimensional coronary MR angiography (3D coronary MRA) with Gd-DTPA administration was performed in 19 patients to evaluate the vascular delineation and diagnostic capability for stenotic lesions. A 3D fast low-angle shot (FLASH) with a navigator echo respiratory gating technique was used with a superconducting 1.5 tesla MR system (Vision, Siemens Medical Systems, Erlangen, Germany). Administration of the conventional T 1 contrast agent with extra-cellular distribution produced a significant increase in the SNR and CNR of the proximal coronary arterial images. Visual score of both the source images and the multiplanar reconstruction (MPR) images assessed by three radiologists was superior to those on control images (without contrast enhancement). The MRA findings of stenotic lesions of the coronary artery were compared with the results of the conventional coronary angiographic study. Overall sensitivity and specificity for the detection of stenosis were almost the same as those of control images. In conclusion, 3D coronary MRA with Gd-DTPA administration improved coronary artery delineation. However, further technical improvements are required to enhance the value of the technique in detecting stenoses. (author)

  18. Optimal timing of coronary invasive strategy in non-ST-segment elevation acute coronary syndromes

    DEFF Research Database (Denmark)

    Navarese, Eliano P; Gurbel, Paul A; Andreotti, Felicita

    2013-01-01

    The optimal timing of coronary intervention in patients with non-ST-segment elevation acute coronary syndromes (NSTE-ACSs) is a matter of debate. Conflicting results among published studies partly relate to different risk profiles of the studied populations.......The optimal timing of coronary intervention in patients with non-ST-segment elevation acute coronary syndromes (NSTE-ACSs) is a matter of debate. Conflicting results among published studies partly relate to different risk profiles of the studied populations....

  19. Coronary Artery Calcium Distribution and Interscan Measurement Variability in End-Stage Renal and Coronary Heart Disease Patients

    International Nuclear Information System (INIS)

    Serafin, Z.; Laskowska, K.; Marzec, M.; Lasek, W.; Sinjab, T.A.; Wlodarczyk, Z.

    2009-01-01

    Background: Coronary heart disease patients and end-stage renal disease patients have been documented to have an increased amount of coronary artery calcifications (CAC). Purpose: To evaluate the distribution of CAC and its influence on interscan variability of measurement in end-stage renal disease and coronary heart disease patients, proven to have calcifications. Material and Methods: 69 patients having CAC, including 34 with coronary heart disease and 35 with end-stage renal disease, were scanned twice with multidetector-row computed tomography (MDCT). Amount of CAC was determined as the number of calcified lesions (CN), total calcium score (CS), calcium volume (CV), and calcium mass (CM). Distribution of CAC was evaluated on a per-patient basis as the median CS and CM of a single lesion. Density of the calcifications was calculated as the patient's CM divided by CV. Results: The overall median CS was 457.2, and the median CM was 75.6 mg. There were no significant differences in the number of calcified lesions, CS, or CM between the two groups. Both CS and CM of a single lesion, as well as the mean calcium density were lower in renal disease patients (P<0.05) than in coronary heart disease subjects. The relative interscan variability of coronary calcium measurement was higher in the renal disease group (P<0.05). There was a negative correlation between the calcium concentration and the relative interscan variability. Conclusion: The results indicate that the coronary calcium distribution influences the measurement interscan reproducibility, and the distribution may differ between end-stage renal disease patients and coronary heart disease patients, reflecting the dissimilar nature of coronary calcifications in those groups

  20. Coronary Artery Calcium Distribution and Interscan Measurement Variability in End-Stage Renal and Coronary Heart Disease Patients

    Energy Technology Data Exchange (ETDEWEB)

    Serafin, Z.; Laskowska, K.; Marzec, M.; Lasek, W. (Dept. of Radiology and Diagnostic Imaging, Nicolaus Copernicus Univ., Collegium Medicum, Bydgoszcz (Poland)); Sinjab, T.A.; Wlodarczyk, Z. (Dept. of Transplantology, Nicolaus Copernicus Univ., Collegium Medicum, Bydgoszcz (Poland))

    2009-04-15

    Background: Coronary heart disease patients and end-stage renal disease patients have been documented to have an increased amount of coronary artery calcifications (CAC). Purpose: To evaluate the distribution of CAC and its influence on interscan variability of measurement in end-stage renal disease and coronary heart disease patients, proven to have calcifications. Material and Methods: 69 patients having CAC, including 34 with coronary heart disease and 35 with end-stage renal disease, were scanned twice with multidetector-row computed tomography (MDCT). Amount of CAC was determined as the number of calcified lesions (CN), total calcium score (CS), calcium volume (CV), and calcium mass (CM). Distribution of CAC was evaluated on a per-patient basis as the median CS and CM of a single lesion. Density of the calcifications was calculated as the patient's CM divided by CV. Results: The overall median CS was 457.2, and the median CM was 75.6 mg. There were no significant differences in the number of calcified lesions, CS, or CM between the two groups. Both CS and CM of a single lesion, as well as the mean calcium density were lower in renal disease patients (P<0.05) than in coronary heart disease subjects. The relative interscan variability of coronary calcium measurement was higher in the renal disease group (P<0.05). There was a negative correlation between the calcium concentration and the relative interscan variability. Conclusion: The results indicate that the coronary calcium distribution influences the measurement interscan reproducibility, and the distribution may differ between end-stage renal disease patients and coronary heart disease patients, reflecting the dissimilar nature of coronary calcifications in those groups.

  1. Posttraumatic Stress Disorder Disturbs Coronary Tone and Its Regulatory Mechanisms.

    Science.gov (United States)

    Lazuko, Svetlana S; Kuzhel, Olga P; Belyaeva, Lyudmila E; Manukhina, Eugenia B; Fred Downey, H; Tseilikman, Olga B; Komelkova, Maria V; Tseilikman, Vadim E

    2018-01-01

    Posttraumatic stress disorder (PTSD) is associated with myocardial injury, but changes in coronary regulatory mechanisms in PTSD have not been investigated. This study evaluated the effect of PTSD-inducing stress on coronary tone and its regulation by nitric oxide (NO) and voltage-gated K + channels. PTSD was induced by exposing rats to predator stress, 15 min daily for 10 days, followed by 14 stress-free days. Presence of PTSD was confirmed by the elevated plus-maze test. Coronary tone was evaluated from changes in coronary perfusion pressure of Langendorff isolated hearts. Predator stress induced significant decreases in coronary tone of isolated hearts and in blood pressure of intact rats. L-NAME, a non-selective NO synthase (NOS) inhibitor, but not S-MT, a selective iNOS inhibitor, and increased coronary tone of control rats. In PTSD rats, both L-NAME and S-MT increased coronary tone. Therefore, the stress-induced coronary vasodilation resulted from NO overproduction by both iNOS and eNOS. NOS induction was apparently due to systemic inflammation as evidenced by increased serum interleukin-1β and C-reactive protein in PTSD rats. Decreased corticosterone in PTSD rats may have contributed to inflammation and its effect on coronary tone. PTSD was also associated with voltage-gated K + channel dysfunction, which would have also reduced coronary tone.

  2. [Single coronary artery and right aortic arch].

    Science.gov (United States)

    Martínez-Quintana, Efrén; Rodríguez-González, Fayna

    2015-01-01

    Coronary anomalies are mostly asymptomatic and diagnosed incidentally during coronary angiography or echocardiography. However, they must be taken into account in the differential diagnosis of angina, dyspnea, syncope, acute myocardial infarction or sudden death in young patients. The case is presented of two rare anomalies, single coronary artery originating from right sinus of Valsalva and right aortic arch, in a 65 year-old patient with atherosclerotic coronary artery disease treated percutaneously. Copyright © 2014 Sociedad Española de Arteriosclerosis. Published by Elsevier España. All rights reserved.

  3. Prognosis for medically treated elderly patients with coronary artery disease. Analysis by the cox model

    International Nuclear Information System (INIS)

    Furuno, Takashi; Yamasaki, Fumiyasu; Yabe, Toshikazu; Matsumura, Yoshihisa; Kitaoka, Hiroaki; Doi, Yoshinori

    1997-01-01

    The prognostic importance of age among well-known prognostic factors such as extent of coronary artery lesions, cardiac function, and myocardial ischemia was evaluated in 147 elderly patients with coronary artery disease aged 65 years or older who underwent dipyridamole perfusion scintigraphy and coronary angiography. After excluding 32 patients who initially underwent percutaneous transluminal coronary angioplasty (PTCA) or coronary artery bypass grafting (CABG), 115 patients who were initially treated medically were analysed by the Cox model for cardiac events during a mean follow-up period of 29±22 months. Among the 114 patients who were available for follow-up, nine patients (7.9%) had cardiac events, including five cardiac deaths and four non-fatal cardiac events (requiring PTCA or CABG). When the 114 patients were divided into three age-groups; 53 patients aged 65-69 years, 42 aged 70-74 years and 19 aged 75 years or older, the incidence of cardiac death was highest in those aged 75 years or older. Univariate analysis showed that age of 70 years or older (hazards ratio 15.15, p=0.004), scintigraphic diffuse slow washout (hazards ratio 8.77, p=0.002), and triple-vessel or left main trunk disease (hazards ratio 6.36, p=0.05) were important prognostic factors. Multivariate analysis showed that scintigraphic diffuse slow washout (hazards ratio 6.33, p=0.05), and triple-vessel or left main trunk disease (hazards ratio 11.94 p=0.05) were statistically significant as independent prognostic factors. However, when age of 70 years or older was included in the analysis, it showed higher hazards ratio (21.21, p=0.03) than that of scintigraphic diffuse slow washout (7.36) or triple-vessel or left main trunk disease (5.30). Age of 70 years or older may be a significant prognostic factor in elderly patients with coronary artery disease which has an equivalent importance to the extent of coronary lesions. (author)

  4. Patient Versus Physician Variation in Use of Transradial Percutaneous Coronary Intervention.

    Science.gov (United States)

    Shamim, Shariq; Tang, Fengming; Safley, David; Jones, Philip; Spertus, John A; Baklanov, Dmitri

    2017-06-15

    The prevalence of radial access for transradial catheterization remains low in the United States, occurring in only 28% of cases in the National Cardiovascular Data Registry (NCDR) CathPCI. It is unknown whether the low adoption rate has been influenced by patient characteristics or is more operator dependent. In a 10-center study, we compared clinical and demographic characteristics among 323 radial and 1,506 femoral access percutaneous coronary intervention (PCIs) performed by 65 interventionists capable of radial PCI. We created a hierarchical logistic regression model to identify operator and patient characteristics associated with radial PCI and the median rate ratio to quantify the variation across operators. A subset was interviewed to assess health literacy and preferences in shared medical decision making. Radial access was used in 17.7% of patients. Patient factors associated with lower rate of radial PCI were previous PCI (33.4% vs 41.4%, p = 0.008), history of coronary artery bypass graft (8.4% vs 23.0%, p <0.001), and chronic total occlusion PCI (10.2% vs 17.9%, p <0.001). Operator characteristics associated with lower rate of radial PCI are being older, being longer in practice, lower number of publications, and Southern practice location. The range of radial use across operators was 1% to 99% and the median rate ratio was 1.97. Patients with radial access had lower health literacy, as assessed by the Rapid Estimate of Adult Literacy in Medicine Revised (REALM) score (6.6 ± 2.6 vs 7.1 ± 2.0, p = 0.03) but did not differ in their preferences for shared decision making. In conclusion, our study demonstrates a high degree of variability of radial access for PCI among different operators, with few differences in patient characteristics, suggesting that improvement efforts should focus on operators. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Coffee consumption and coronary calcification - The Rotterdam Coronary Calcification Study

    NARCIS (Netherlands)

    van Woudenbergh, Geertruida J.; Vliegenthart, Rozemarijn; van Rooij, Frank J. A.; Hofman, Albert; Oudkerk, Matthijs; Witteman, Jacqueline C. M.; Geleijnse, Johanna M.

    Background-The role of coffee in the cardiovascular system is not yet clear. We examined the relation of coffee intake with coronary calcification in a population-based cohort. Methods and Results-The study involved 1570 older men and women without coronary heart disease who participated in the

  6. Complete remission of coronary vasculitis in Churg-Strauss Syndrome by prednisone and cyclophosphamide

    NARCIS (Netherlands)

    Riksen, N.P.; Gehlmann, H.R.; Brouwer, A.E.; Deuren, M. van

    2013-01-01

    The heart is involved in up to 50% of all patients with Churg-Strauss syndrome, but vasculitis of the coronary arteries has only been rarely documented. We present a young patient with severe coronary aneurysms and stenotic lesions due to a Churg-Strauss vasculitis. Prompt therapy with prednisone

  7. Coronary CT angiography in clinical triage of patients at high risk of coronary artery disease

    DEFF Research Database (Denmark)

    Kühl, J Tobias; Hove, Jens D; Kristensen, Thomas S

    2017-01-01

    OBJECTIVES: To test if cardiac computed tomography angiography (CCTA) can be used in the triage of patients at high risk of coronary artery disease. DESIGN: The diagnostic value of 64-detector CCTA was evaluated in 400 patients presenting with non-ST segment elevation myocardial infarction using...... invasive coronary angiography (ICA) as the reference method. The relation between the severity of disease by CCTA and a combined endpoint of death, re-hospitalization due to new myocardial infarction, or symptom-driven coronary revascularization was assessed. RESULTS: CCTA detects significant (>50...... in patients with high likelihood of coronary artery disease and could, in theory, be used to triage high risk patients. As many obstacles remain, including logistical and safety issues, our study does not support the use of CCTA as an additional diagnostic test before ICA in an all-comer NSTEMI population....

  8. [Surgical angioplasty of the left main coronary artery].

    Science.gov (United States)

    Vranes, Mile; Velinović, Milos; Kocica, Mladen; Mikić, Aleksandar; Velimirović, Dusan; Djukić, Petar

    2010-01-01

    The conventional treatment for isolated stenosis of the left main coronary artery is bypass surgery (myocardial revascularization). However, the process of atherosclerosis is not arrested by myocardial revascularization and it will lead to the occlusion of the left main coronary artery. Revascularization will establish retrograde perfusion for 50-70% of the myocardium of the left ventricle. Direct surgical angioplasty of the left main coronary artery enables normal physiological perfusion of the whole myocardium and better myocardial function. The aim of our study is to point out a new surgical approach of treating left main coronary artery stenosis. Between October 2002 and October 2003, direct surgical angioplasty of the main left coronary artery was performed on three patients with isolated stenosis of the left main coronary artery using the anterior approach and the pericardium as a patch. The procedure was performed under total endotracheal anaesthesia and standard cardiopulmonary circulation, moderate hypothermia, anterograde St. Tomas cardioplegia and local cooling. Patients were followed clinically, echocardiographically and by load-tests. All three patients were without complications. In postoperative follow-up (54-68 months) neither angina pectoris nor electrocardiographically registered ischaemic changes were found. Load-tests performed every six months on all three patients were negative. Surgical angioplasty of isolated stenosis of the left main coronary artery is a preferred method for treating this type of coronary disease. Contraindications for this type of treatment are stenosis of the left main coronary artery with bifurcation and advanced calcification of the left main coronary artery.

  9. Comparison of Early Outcomes with Three Approaches for Combined Coronary Revascularization and Carotid Endarterectomy

    Directory of Open Access Journals (Sweden)

    Arzu Antal Dönmez

    Full Text Available Abstract Objective: This study aims to compare three different surgical approaches for combined coronary and carotid artery stenosis as a single stage procedure and to assess effect of operative strategy on mortality and neurological complications. Methods: This retrospective study involves 136 patients who had synchronous coronary artery revascularization and carotid endarterectomy in our institution, between January 2002 and December 2012. Patients were divided into 3 groups according to the surgical technique used. Group I included 70 patients who had carotid endarterectomy, followed by coronary revascularization with on-pump technique, group II included 29 patients who had carotid endarterectomy, followed by coronary revascularization with off-pump technique, group III included 37 patients who had coronary revascularization with on-pump technique followed by carotid endarterectomy under aortic cross-clamp and systemic hypothermia (22-27ºC. Postoperative outcomes were evaluated. Results: Overall early mortality and stroke rate was 5.1% for both. There were 3 (4.3% deaths in group I, 2 (6.9% deaths in group II and 2 (5.4% deaths in group III. Stroke was observed in 5 (7.1% patients in group I and 2 (6.9% in group II. Stroke was not observed in group III. No statistically significant difference was observed for mortality and stroke rates among the groups. Conclusion: We identified no significant difference in mortality or neurologic complications among three approaches for synchronous surgery for coronary and carotid disease. Therefore it is impossible to conclude that a single principle might be adapted into standard practice. Patient specific risk factors and clinical conditions might be important in determining the surgical tecnnique.

  10. Receiver operating characteristic analysis improves diagnosis by radionuclide ventriculography

    International Nuclear Information System (INIS)

    Dickinson, C.Z.; Forman, M.B.; Vaugh, W.K.; Sandler, M.P.; Kronenberg, M.W.

    1985-01-01

    Receiver operating characteristic analysis (ROC) evaluates continuous variables to define diagnostic criteria for the optimal sensitivity (SENS) and specificity (SPEC) of a test. The authors studied exercise-induced chest pain (CP), ST-changes on electrocardiography (ECG) and rest-exercise gated radionuclide ventriculography (RVG) using ROC to clarify the optimal criteria for detecting myocardial ischemia due to coronary artherosclerosis (CAD). The data of 95 consecutive patients studied with coronary angiography, rest-exercise RVG and ECG were reviewed. 77 patients had ''significant'' CAD (≥50% lesions). Exercise-induced CP, ECG abnormalities (ST-T shifts) and RVG abnormalities (change in ejection fraction, 2-view regional wall motion change and relative end-systolic volume) were evaluated to define optimal SENS/SPEC of each and for the combined data. ROC curves were constructed by multiple logistic regression (MLR). By MLR, RVG alone was superior to ECG and CP. The combination of all three produced the best ROC curve for the entire group and for clinical subsets based on the number of diseased vessels and the presence or absence of prior myocardial infarction. When CP, ECG and RVG were combined, the optimal SENS/SPEC for detection of single vessel disease was 88/86. The SENS/SPEC for 3 vessel disease was 93/95. Thus, the application of RVG for the diagnosis of myocardial ischemia is improved with the inclusion of ECG and CP data by the use of a multiple logistic regression model. ROC analysis allows clinical application of multiple data for diagnosing CAD at desired SENS/SPEC rather than by arbitrary single-standard criteria

  11. General Anesthesia in the Surgical Treatment of Coronary Heart Disease

    Directory of Open Access Journals (Sweden)

    N. A. Karpun

    2012-01-01

    Full Text Available The paper deals with the problem of anesthetic maintenance during surgical correction of coronary blood flow. The basis for this is the results of the investigations conducted at the V. A. Negovsky Research Institute of General Reanimatology, the objective of which was to improve the results of surgical treatment in patients with different forms of coronary heart disease (CHD, by optimizing the anesthetic maintenance of open heart surgery. Clinical and special examinations were made in 367 patients who had undergone surgical treatment (aortocoronary bypass surgery; formation of a mammary coronary anastomosis; resection and plastic repair of left ventricular aneurysms; thrombectomy from the heart chambers for CHD and its complications. The main methodological approach to this study is to personalize intensive therapy and general anesthesia, which are relied on both evidence-based medicine and an individual pathophysiological approach. The paper details how to choose the basic mode of general anesthesia depending on the form of CHD and myocardial contractile function. Furthermore, the authors propose methods for optimizing the perioperative period: postoperative analgesia; correction of the aggregate state of blood; operative hemodilution; prevention and correction of critically reduced blood oxygen capacity 

  12. Imaging techniques in the diagnosis of coronary heart disease

    International Nuclear Information System (INIS)

    Frank, H.

    1997-01-01

    Coronary heart disease is the leading cause of death and disability worldwide. Coronary angiography makes it possible to visualize coronary artery stenosis and can be used for angioplasty and stent implantation; however, it does not allow the assessment of changes in myocardial microcirculation. The severity of an angiographically evaluated coronary stenosis does not always correspond to the extent of myocardial ischemia. Nonivasive techniques are needed to reexamine our reliance on coronary angiography and to explore the clinical value fo the physiological assessment of coronary artery stenoses. Such noninvasive techniques might become important tools in the future following an overal evaluation of coronary morphology, myocardial function and perfusion ascertained by all available methods. (orig.) [de

  13. Sand transport in a two pass internal cooling duct with rib turbulators

    International Nuclear Information System (INIS)

    Singh, Sukhjinder; Tafti, Danesh; Reagle, Colin; Delimont, Jacob; Ng, Wing; Ekkad, Srinath

    2014-01-01

    Highlights: • Highest particle impingement observed in the bend and first quarter of 2nd pass. • Average particle impingement per pitch is 28% higher in the second pass. • Rib faces are by far the most susceptible to particle impingement. • Particle impingement is sensitive to particle size. • Particle impingement is sensitive to wall collision model used. - Abstract: Jet engines often operate under dirty conditions where large amounts of particulate matter can be ingested, especially, sand, ash and dirt. Particulate matter in different engine components can lead to degradation in performance. The focus of this study is to investigate the sand transport and deposition in the internal cooling passages of turbine blades. A two pass stationary square duct with rib turbulators subjected to sand ingestion is studied using Large Eddy Simulations (LES). Each pass has ribs on two opposite walls and aligned normal to the main flow direction. The rib pitch to rib height (P/e) is 9.28, the rib height to channel hydraulic diameter (e/D h ) is 0.0625 and calculations have been carried out for a bulk Reynolds number of 25,000. Particle sizes in the range 0.5–25 μm are considered, with the same size distribution as found in Arizona Road Dust (medium). Large Eddy Simulation (LES) with a wall-model is used to model the flow and sand particles are modeled using a discrete Lagrangian framework. Results quantify the distribution of particle impingement density on all surfaces. Highest particle impingement density is found in the first quarter section of the second pass after the 180° turn, where the recorded impingement is more than twice that of any other region. It is also found that the average particle impingement per pitch is 28% higher in the second pass than the first pass. Results show lower particle tendency to impact the region immediately behind the rib in the first pass compared to the second pass where particle impingement is more uniform in the region

  14. Cross-reacting antibacterial auto-antibodies are produced within coronary atherosclerotic plaques of acute coronary syndrome patients.

    Directory of Open Access Journals (Sweden)

    Filippo Canducci

    Full Text Available Coronary atherosclerosis, the main condition predisposing to acute myocardial infarction, has an inflammatory component caused by stimuli that are yet unknown. We molecularly investigated the nature of the immune response within human coronary lesion in four coronary plaques obtained by endoluminal atherectomy from four patients. We constructed phage-display libraries containing the IgG1/kappa antibody fragments produced by B-lymphocytes present in each plaque. By immunoaffinity, we selected from these libraries a monoclonal antibody, arbitrarily named Fab7816, able to react both with coronary and carotid atherosclerotic tissue samples. We also demonstrated by confocal microscopy that this monoclonal antibody recognized human transgelin type 1, a cytoskeleton protein involved in atherogenesis, and that it co-localized with fibrocyte-like cells transgelin+, CD68+, CD45+ in human sections of coronary and carotid plaques. In vitro fibrocytes obtained by differentiating CD14+ cells isolated from peripheral blood mononuclear cells also interacted with Fab7816, thus supporting the hypothesis of a specific recognition of fibrocytes into the atherosclerotic lesions. Interestingly, the same antibody, cross-reacted with the outer membrane proteins of Proteus mirabilis and Klebsiella pneumoniae (and possibly with homologous proteins of other enterobacteriaceae present in the microbiota. From all the other three libraries, we were able to clone, by immunoaffinity selection, human monoclonal antibodies cross-reacting with bacterial outer membrane proteins and with transgelin. These findings demonstrated that in human atherosclerotic plaques a local cross-reactive immune response takes place.

  15. Gain claming in single-pass and double-pass L-band erbium-doped fiber amplifiers

    International Nuclear Information System (INIS)

    Harun, S.W.; Ahmad, H.

    2004-01-01

    Gain clamping is demonstrated in single-pass and double-pass long wavelength band erbium-doped fiber amplifiers. A C/L-band wavelength division multiplexing coupler is used in single-pass system to generate a laser at 1566 nm. The gain for the amplifier is clamped at 15.5 dB with gain variation of less than 0.2 dB from input signal power of -40 to -14 dBm with almost negligible noise figure penalty. However, the flatness of gain spectrum is slightly degraded due to the un-optimisation of erbium-doped fiber length. The advantage of this configuration is that the oscillating light does not appear at the output of the amplifier. A highly efficient gain-clamped long wavelength band erbium-doped fiber amplifiers with improved noise figure characteristic is demonstrated by simply adding a broadband conventional band fiber Bragg grating in double pass system. The combination of the fiber Bragg grating and optical circulator has created laser in the cavity for gain clamping. By adjusting the power combination of pumps 1 and 2, the clamped gain level can be controlled. The amplifier gain is clamped at 28.1 dB from -40 to -25 dBm with gain variation of less than 0.5 dB by setting the pumps 1 and 2 at 59.5 and 50.6 mW, respectively. The gain is also flat from 1574 nm to 1604 nm with gain variation of less than 3 dB. The corresponding noise figure varies from 5.6 to 7.6 dB, which is 0.8 to 2.6 dB reduced compared to those of unclamped amplifier (Authors)

  16. Coffee Consumption and Coronary Calcification: The Rotterdam Coronary Calcification Study

    NARCIS (Netherlands)

    Woudenbergh, van G.J.; Vliegenthart, R.; Rooij, van F.J.A.; Hofman, A.; Oudkerk, M.; Witteman, J.C.M.; Geleijnse, J.M.

    2008-01-01

    Background¿ The role of coffee in the cardiovascular system is not yet clear. We examined the relation of coffee intake with coronary calcification in a population-based cohort. Methods and Results¿ The study involved 1570 older men and women without coronary heart disease who participated in the

  17. The Angio-Seal™ femoral closure device allows immediate ambulation after coronary angiography and percutaneous coronary intervention

    DEFF Research Database (Denmark)

    Hvelplund, Anders; Jeger, Raban; Osterwalder, Remo

    2011-01-01

    To test the safety of immediate mobilisation of patients undergoing coronary angiography and percutaneous coronary intervention (PCI) closed with Angio-Seal™ -a femoral vascular closure device.......To test the safety of immediate mobilisation of patients undergoing coronary angiography and percutaneous coronary intervention (PCI) closed with Angio-Seal™ -a femoral vascular closure device....

  18. Highly efficient single-pass sum frequency generation by cascaded nonlinear crystals

    DEFF Research Database (Denmark)

    Hansen, Anders Kragh; Andersen, Peter E.; Jensen, Ole Bjarlin

    2015-01-01

    , despite differences in the phase relations of the involved fields. An unprecedented 5.5 W of continuous-wave diffraction-limited green light is generated from the single-pass sum frequency mixing of two diode lasers in two periodically poled nonlinear crystals (conversion efficiency 50%). The technique......The cascading of nonlinear crystals has been established as a simple method to greatly increase the conversion efficiency of single-pass second-harmonic generation compared to a single-crystal scheme. Here, we show for the first time that the technique can be extended to sum frequency generation...... is generally applicable and can be applied to any combination of fundamental wavelengths and nonlinear crystals....

  19. Evaluation of left ventricular ejection fraction by first pass radionuclide cardioangiography

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, T; Imai, Y; Kagawa, M; Hayashi, M; Kozuka, T [National Cardiovascular Center, Suita, Osaka (Japan)

    1980-02-01

    The left ventricular ejection fraction can be assessed by recording the passage of peripherally administered radioactive bolus through the heart which is first pass method. In this study, the accuracy and validity of first pass method were examined in the patients with cardiac catheterization. After sup(99m)Tc-HSA as a bolus was injected intravenouslly, the time-activity curve was recorded with a scintillation camera and online minicomputer system. The ejection fraction was calculated by the average of three cardiac cycles which corresponded to the left ventricular volume changes during each cardiac cycles. The results correlated well with those obtained by biplane cineangiography in the twenty patients without arrythmias (r = 0.89) and moreover, this technique was applied to the fifteen patients with atrial fibrillation such as mitral valvular diseases, congestive cardiomyopathy, Good correlation of the ejection fraction (r = 0.84) was obtained. The findings, however, demonstrated that the time-activity curve must be generated from the region of interest which fits the left ventricular blood pool precisely and must be corrected for the contribution arizing from noncardiac background structures (two matrix method). In conclusion, this noninvasive method appears particularly useful for serial evaluation of the patients with cardiac dysfunctions and would be available for the routine examination of ventricular functions.

  20. Detection of angina-related coronary artery in patients with unstable angina pectoris by using 123I-BMIPP myocardial scintigraphy

    International Nuclear Information System (INIS)

    Oka, Toshiaki; Inoue, Seiji; Asano, Ryuta; Handa, Atsushi; Iguchi, Nobuo; Sumiyoshi, Tetsuya; Hosoda, Saichi; Kobayashi, Hideki; Kusakabe, Kiyoko.

    1996-01-01

    To evaluate the diagnostic accuracy of detection of angina-related coronary arteries in patients with unstable angina pectoris. Twenty patients with unstable angina pectoris underwent 123 I-BMIPP scintigraphy at rest. A mean duration from last anginal attack to 123 I-BMIPP scintigraphy was 4.8±3.2 days. Seventeen of 20 angina-related coronary territories were detected by reduced 123 -BMIPP uptake. The sensitivity and specificity for detection of angina-related coronary arteries were 85% and 95%, respectively. The decrease in myocardial uptake of 123 I-BMIPP agreed with the decrease in regional wall motion by using ultrasonic echocardiography. 123 I-BMIPP scintigraphy may be useful for detection of angina-related coronary artery in a routine clinical examination in patients with unstable angina pectoris. (author)

  1. Diagnostic performance of instantaneous wave-free ratio for the evaluation of coronary stenosis severity confirmed by fractional flow reserve: A PRISMA-compliant meta-analysis of randomized studies.

    Science.gov (United States)

    Man, Wanrong; Hu, Jianqiang; Zhao, Zhijing; Zhang, Mingming; Wang, Tingting; Lin, Jie; Duan, Yu; Wang, Ling; Wang, Haichang; Sun, Dongdong; Li, Yan

    2016-09-01

    The instantaneous wave-free ratio (iFR) is a new vasodilator-free index of coronary stenosis severity. The aim of this meta-analysis is to assess the diagnostic performance of iFR for the evaluation of coronary stenosis severity with fractional flow reserve as standard reference. We searched PubMed, EMBASE, CENTRAL, ProQuest, Web of Science, and International Clinical Trials Registry Platform (ICTRP) for publications concerning the diagnostic value of iFR. We used a random-effects covariate to synthesize the available data of sensitivity, specificity, positive likelihood ratio (LR+), negative likelihood ratio (LR-), and diagnostic odds ratio (DOR). Overall test performance was summarized by the summary receiver operating characteristic curve (sROC) and the area under the curve (AUC). Eight studies with 1611 subjects were included in the meta-analysis. The pooled sensitivity, specificity, LR+, LR-, and DOR for iFR were respectively 73.3% (70.1-76.2%), 86.4% (84.3-88.3%), 5.71 (4.43-7.37), 0.29 (0.22-0.38), and 20.54 (16.11-26.20). The area under the summary receiver operating characteristic curves for iFR was 0.8786. No publication bias was identified. The available evidence suggests that iFR may be a new, simple, and promising technology for coronary stenosis physiological assessment.

  2. Reproducibility of coronary atherosclerotic plaque characteristics in populations with low, intermediate, and high prevalence of coronary artery disease by multidetector computer tomography

    DEFF Research Database (Denmark)

    de Knegt, Martina C; Linde, Jesper J; Fuchs, Andreas

    2016-01-01

    To evaluate the interobserver agreement of visual coronary plaque characteristics by 320-slice multidetector computed tomography (MDCT) in three populations with low, intermediate and high CAD prevalence and to identify determinants for the reproducible assessment of these plaque characteristics...

  3. Quantitative relationship between coronary artery calcium and myocardial blood flow by hybrid rubidium-82 PET/CT imaging in patients with suspected coronary artery disease.

    Science.gov (United States)

    Assante, Roberta; Zampella, Emilia; Arumugam, Parthiban; Acampa, Wanda; Imbriaco, Massimo; Tout, Deborah; Petretta, Mario; Tonge, Christine; Cuocolo, Alberto

    2017-04-01

    We assessed the relationship between coronary artery calcium (CAC) score, myocardial blood flow (MBF) and coronary flow reserve (CFR) in patients undergoing hybrid 82 Rb positron emission tomography (PET)/computed tomography (CT) imaging for suspected CAD. We also evaluated if CAC score is able to predict a reduced CFR independently from conventional coronary risk factors. A total of 637 (mean age 58 ± 13 years) consecutive patients were studied. CAC score was measured according to the Agatston method and patients were categorized into 4 groups (0, 0.01-99.9, 100-399.9, and ≥400). Baseline and hyperemic MBF were automatically quantified. CFR was calculated as the ratio of hyperemic to baseline MBF and it was considered reduced when <2. Global CAC score showed a significant inverse correlation with hyperemic MBF and CFR (both P < .001), while no correlation between CAC score and baseline MBF was found. At multivariable logistic regression analysis age, diabetes and CAC score were independently associated with reduced CFR (all P < .001). The addition of CAC score to clinical data increased the global chi-square value for predicting reduced CFR from 81.01 to 91.13 (P < .01). Continuous net reclassification improvement, obtained by adding CAC score to clinical data, was 0.36. CAC score provides incremental information about coronary vascular function over established CAD risk factors in patients with suspected CAD and it might be helpful for identifying those with a reduced CFR.

  4. Morphometry of the coronary ostia and the structure of coronary arteries in the shorthair domestic cat.

    Directory of Open Access Journals (Sweden)

    Karolina Barszcz

    Full Text Available The aim of this study was to measure the area of the coronary ostia, assess their localization in the coronary sinuses and to determine the morphology of the stem of the left and right coronary arteries in the domestic shorthair cat. The study was conducted on 100 hearts of domestic shorthair cats of both sexes, aged 2-18 years, with an average body weight of 4.05 kg. A morphometric analysis of the coronary ostia was carried out on 52 hearts. The remaining 48 hearts were injected with a casting material in order to carry out a morphological assessment of the left and right coronary arteries. In all the studied animals, the surface of the left coronary artery ostium was larger than the surface of the right coronary artery ostium. There were four types of the left main coronary artery: type I (23 animals, 49%-double-branched left main stem (giving off the left circumflex branch and the interventricular paraconal branch, which in turn gave off the septal branch, type II (12 animals, 26%-double-branched left main stem (giving off the left circumflex branch and the interventricular paraconal branch without the septal branch, type III (11 animals, 23%-triple-branched left main stem (giving off the left circumflex branch, interventricular branch and the septal branch, type IV (1 animal, 2%-double-branched left main stem (giving off the interventricular paraconal branch and the left circumflex branch, which in turn gave off the septal branch. The left coronary artery ostium is greater than the right one. There is considerable diversity in the branches of proximal segment of the left coronary artery, while the right coronary artery is more conservative. These results can be useful in defining the optimal strategies in the endovascular procedures involving the coronary arteries or the aortic valve in the domestic shorthair cat.

  5. Coronary artery bypass surgery in a patient with Kartagener syndrome: a case report and literature review

    Directory of Open Access Journals (Sweden)

    Bougioukas Ioannis

    2010-08-01

    Full Text Available Abstract Kartagener syndrome consists of congenital bronchiectasis, sinusitis, and total situs inversus in half of the patients. A patient diagnosed with Kartagener syndrome was reffered to our department due to 3-vessel coronary disease. An off-pump coronary artery bypass operation was performed using both internal thoracic arteries and a saphenous vein graft. We performed a literature review for cases with Kartagener syndrome, coronary surgery and dextrocardia. Although a few cases of dextrocardia were found in the literature, no case of Kartagener syndrome was mentioned.

  6. Analysis of Biomechanical Structure and Passing Techniques in Basketball

    OpenAIRE

    Ricardo E. Izzo; Luca Russo

    2011-01-01

    The basketball is a complex sport, which these days has become increasingly linked to its’ psychophysical aspects rather than to the technical ones. Therefore, it is important to make a through study of the passing techniques from the point of view of the type of the pass and its’ biomechanics. From the point of view of the type of the used passes, the most used is the two-handed chest pass with a frequency of 39.9%. This is followed, in terms of frequency, by one-handed passes – the baseball...

  7. Coronary triglyceride deposition in contemporary advanced diabetics.

    Science.gov (United States)

    Ikeda, Yoshihiko; Zaima, Nobuhiro; Hirano, Ken-ichi; Mano, Masayuki; Kobayashi, Kunihisa; Yamada, Sohsuke; Yamaguchi, Satoshi; Suzuki, Akira; Kanzaki, Hideaki; Hamasaki, Toshimitsu; Kotani, Jun-ichi; Kato, Seiya; Nagasaka, Hironori; Setou, Mitsutoshi; Ishibashi-Ueda, Hatsue

    2014-07-01

    It is of importance to clarify pathophysiology of diabetic heart diseases such as heart failure and coronary artery disease. We reported a novel clinical phenotype called triglyceride deposit cardiomyovasculopathy (TGCV), showing aberrant TG accumulation in both coronary arteries and myocardium, in a cardiac transplant recipient. Here, we examined autopsied diabetics for TG deposition in cardiovasculature. Consecutive series of hearts from advanced diabetes mellitus (DM) subjects (DM group: DMG, n = 20) and those from age- and sex-matched non-diabetic controls (non DM group: NDMG, n = 20) were examined. The diagnostic criteria of 'advanced DM' was made based on 2014 Clinical Practice Recommendations proposed by the American Diabetes Association. The mean duration of DM was 15.8 years. All DMG suffered from heart diseases including coronary artery diseases and 14 subjects had multi-vessel disease. Tissue TG contents were measured biochemically. Coronary arterial TG contents was significantly higher in DMG compared with NDMG. Spatial distribution of TG in transverse sections of coronary arteries showed TG deposition mainly in smooth muscle cells by Imaging Mass Spectrometry. Abundant TG deposition in coronary artery might be associated with advanced DM. © 2014 Japanese Society of Pathology and Wiley Publishing Asia Pty Ltd.

  8. Dynamic interaction between myocardial contraction and coronary flow.

    Science.gov (United States)

    Beyar, R; Sideman, S

    1997-01-01

    Phasic coronary flow is determined by the dynamic interaction between central hemodynamics and myocardial and ventricular mechanics. Various models, including the waterfall, intramyocardial pump and myocardial structural models, have been proposed for the coronary circulation. Concepts such as intramyocardial pressure, local elastance and others have been proposed to help explain the coronary compression by the myocardium. Yet some questions remain unresolved, and a new model has recently been proposed, linking a muscle collagen fibrous model to a physiologically based coronary model, and accounting for transport of fluids across the capillaries and lymphatic flow between the interstitial space and the venous system. One of the unique features of this model is that the intramyocardial pressure (IMP) in the interstitial space is calculated from the balance of forces and fluid transport in the system, and is therefore dependent on the coronary pressure conditions, the myocardial function and the transport properties of the system. The model predicts a wide range of experimentally observed phenomena associated with coronary compression.

  9. High-pass filtering of input signals by the Ih current in a non-spiking neuron, the retinal rod bipolar cell.

    Directory of Open Access Journals (Sweden)

    Lorenzo Cangiano

    Full Text Available Hyperpolarization-activated cyclic nucleotide-sensitive (HCN channels mediate the I(f current in heart and I(h throughout the nervous system. In spiking neurons I(h participates primarily in different forms of rhythmic activity. Little is known, however, about its role in neurons operating with graded potentials as in the retina, where all four channel isoforms are expressed. Intriguing evidence for an involvement of I(h in early visual processing are the side effects reported, in dim light or darkness, by cardiac patients treated with HCN inhibitors. Moreover, electroretinographic recordings indicate that these drugs affect temporal processing in the outer retina. Here we analyzed the functional role of HCN channels in rod bipolar cells (RBCs of the mouse. Perforated-patch recordings in the dark-adapted slice found that RBCs exhibit I(h, and that this is sensitive to the specific blocker ZD7288. RBC input impedance, explored by sinusoidal frequency-modulated current stimuli (0.1-30 Hz, displays band-pass behavior in the range of I(h activation. Theoretical modeling and pharmacological blockade demonstrate that high-pass filtering of input signals by I(h, in combination with low-pass filtering by passive properties, fully accounts for this frequency-tuning. Correcting for the depolarization introduced by shunting through the pipette-membrane seal, leads to predict that in darkness I(h is tonically active in RBCs and quickens their responses to dim light stimuli. Immunohistochemistry targeting candidate subunit isoforms HCN1-2, in combination with markers of RBCs (PKC and rod-RBC synaptic contacts (bassoon, mGluR6, Kv1.3, suggests that RBCs express HCN2 on the tip of their dendrites. The functional properties conferred by I(h onto RBCs may contribute to shape the retina's light response and explain the visual side effects of HCN inhibitors.

  10. First pass effect by infusing 99mTc-human serum albumin into the hepatic artery

    International Nuclear Information System (INIS)

    Ozawa, Takashi; Kimura, Kousaburou; Koyanagi, Yasuhisa

    1988-01-01

    The fundamental principles of intra-arterial infusion chemotherapy are thought to be increased local drug concentration and the ''first-pass'' effect. The concentration in the rest of the body can only be decreased if there is local elimination of the infused drug before reaching the systemic circulation. This is referred to as the ''first-pass'' effect. In the evaluation of ''first-pass'' effect, the uptake of liver after infusing 99m Tc-human serum albumin ( 99m Tc-HSA) in the hepatic artery by injecting the subcutaneously implanted silicon reservoir was compared with that obtained after intravenous administration of 99m Tc-HSA. In order to remove the factor of portal infusion, each count of liver up take had been continued for only 24 seconds after starting the liver uptake. The results are as follows : for 24 cases excepting 6 cases with catheter obstruction, the mean i.a./i.v. ratio was 7.92 ± 3.34 (range 3.25 to 17.25). Although the elimination rate of drugs in the liver varies with each drug, the infusion of intraarterial chemotherapy should be about 8 times more concentrative than intravenous administration on the ''first-pass'' effect. (author)

  11. Relationship between internal medicine program board examination pass rates, accreditation standards, and program size.

    Science.gov (United States)

    Falcone, John L; Gonzalo, Jed D

    2014-01-19

    To determine Internal Medicine residency program compliance with the Accreditation Council for Graduate Medical Education 80% pass-rate standard and the correlation between residency program size and performance on the American Board of Internal Medicine Certifying Examination. Using a cross-sectional study design from 2010-2012 American Board of Internal Medicine Certifying Examination data of all Internal Medicine residency pro-grams, comparisons were made between program pass rates to the Accreditation Council for Graduate Medical Education pass-rate standard. To assess the correlation between program size and performance, a Spearman's rho was calculated. To evaluate program size and its relationship to the pass-rate standard, receiver operative characteristic curves were calculated. Of 372 Internal Medicine residency programs, 276 programs (74%) achieved a pass rate of =80%, surpassing the Accreditation Council for Graduate Medical Education minimum standard. A weak correlation was found between residency program size and pass rate for the three-year period (p=0.19, pInternal Medicine residency programs complied with Accreditation Council for Graduate Medical Education pass-rate standards, a quarter of the programs failed to meet this requirement. Program size is positively but weakly associated with American Board of Internal Medicine Certifying Examination performance, suggesting other unidentified variables significantly contribute to program performance.

  12. Glucosa-Insulin-Potassium (GIK) solution used with diabetic patients provides better recovery after coronary bypass operations.

    Science.gov (United States)

    Straus, Slavenka; Gerc, Vjekoslav; Kacila, Mirsad; Faruk, Custovic

    2013-01-01

    Tight blood glucose control has become a therapeutical goal for anesthetic management for patients scheduled for cardiac surgery, especially if they are diabetic patients. This study was created to confirm the benefits of intraoperative GIK solution usage during coronary bypass operation of diabetic patients. Patients with type 1 and 2 diabetes mellitus (DM) referred for coronary artery bypass grafting (CABG) were randomized to receive GIK solution (GIK--study group) in the first 24 hours intraoperatively or to receive official Clinical protocol without GIK solution (non GIK - control group). The primary clinical outcome was the cardiac index (CI) since it represents the most sensitive measure of cardiac work in the immediate postoperative period, and the secondary clinical outcomes were the glycemic control, insulin consumption, duration of mechanical ventilation (MV), potassium level and atrial fibrillation (AF) appearance. One hundred diabetic patients, divided into two groups, were included in the study. The cardiac index did not show a significant difference, although the study group had CI with only minor variations than those of the controlled group, hence the reason we considered the study group as the more stable. The atrial fibrillation showed a difference between two groups, with 14 (28%) patients with postoperative AF in the control group compared with 3 (6%) patients with postoperative AF in the study group. As potassium values were stable in study group, we concluded that it can be one of the reasons for less postoperative AF in this group. The duration of MV showed a significant difference (0,003) between the two groups as well. In the study group the average MV time was 534,38 minutes, compared with the control group with 749,20 minutes. The average value of glucose was 11.1 mmol/l in the control group vs. 9.8 mmol/l in the study group. The study group had less insulin consumption in order to maintain target glycemia (p = 0.001). In the non GIK

  13. Aneurysmal coronary artery disease: An overview

    Science.gov (United States)

    ElGuindy, Mohamed S.

    Aneurysmal coronary artery disease (ACAD) comprises both coronary artery aneurysms (CAA) and coronary artery ectasia (CAE). The reported prevalence of ACAD varies widely from 0.2 to 10%, with male predominance and a predilection for the right coronary artery (RCA). Atherosclerosis is the commonest cause of ACAD in adults, while Kawasaki disease is the commonest cause in children and adolescents, as well as in the Far East. Most patients are asymptomatic, but when symptoms do exist, they are usually related to myocardial ischemia. Coronary angiography is the mainstay of diagnosis, but follow up is best achieved using noninvasive imaging that does not involve exposure to radiation. The optimal management strategy in patients with ACAD remains controversial. Medical therapy is indicated for the vast majority of patients and includes antiplatelets and/or anticoagulants. Covered stents effectively limit further expansion of the affected coronary segments. Surgical ligation, resection, and coronary artery bypass grafting are appropriate for large lesions and for associated obstructive coronary artery disease. PMID:29564347

  14. Greek Acute Coronary Syndrome Score for the Prediction of In-hospital and 30-Day Mortality of Patients With an Acute Coronary Syndrome.

    Science.gov (United States)

    Panagiotakos, Demosthenes B; Pitsavos, Christos; Georgousopoulou, Ekavi N; Notara, Venetia; Stefanadis, Christodoulos

    2015-01-01

    Risk evaluation of patients hospitalized with acute coronary syndrome (ACS) may contribute to their short-term prognosis improvement. The aim of this work was to develop a prediction index (score) for the risk assessment of 30-day death of ACS patients, using clinical and biological measurements at hospital admission. A sample of 6 Greek hospitals was selected, and almost all consecutive 2172 ACS patients from October 2003 to September 2004 were enrolled. Sociodemographic, biochemical, clinical, and lifestyle characteristics were recorded. Using as components age, systolic blood pressure, white blood cell count, creatine kinase-MB, and creatinine levels at the time of admission and the time between the onset of symptoms and presentation at hospital, a risk score (Greek Acute Coronary Syndrome score; range, 6-36) was developed and tested against in-hospital and 30-day outcome of the patients. The Greek Acute Coronary Syndrome score showed strong discriminating ability for in-hospital mortality (area under the receiver operating characteristic curve, 0.812; 95% confidence interval, 0.750-0.874; P period.

  15. Nuclear cardiology and coronary surgery

    DEFF Research Database (Denmark)

    Eckardt, R.; Andersen, L.I.; Hesse, B.

    2008-01-01

    Rising age, repeated percutaneous coronary revascularizations, and co-morbidity such as overweight, diabetes, and hypertension, characterize a change over the last 20-30 years in coronary patients referred to coronary artery bypass grafting (CABG). This patient group represents a great part of to...

  16. Model for Estimation of Thermal History Produced by a Single Pass Underwater Wet Weld

    National Research Council Canada - National Science Library

    Dill, Jay

    1997-01-01

    Thermal history calculations for single pass underwater wet weldments were made by solving the appropriate beat transfer equations using the three-dimensional Crank-Nicholson finite difference method...

  17. Left main coronary artery obstruction by dislodged native-valve calculus after transcatheter aortic valve replacement.

    Science.gov (United States)

    Durmaz, Tahir; Ayhan, Huseyin; Keles, Telat; Aslan, Abdullah Nabi; Erdogan, Kemal Esref; Sari, Cenk; Bilen, Emine; Akcay, Murat; Bozkurt, Engin

    2014-08-01

    Transcatheter aortic valve replacement can be an effective, reliable treatment for severe aortic stenosis in surgically high-risk or ineligible patients. However, various sequelae like coronary artery obstruction can occur, not only in the long term, but also immediately after the procedure. We present the case of a 78-year-old woman whose left main coronary artery became obstructed with calculus 2 hours after the transfemoral implantation of an Edwards Sapien XT aortic valve. Despite percutaneous coronary intervention in that artery, the patient died. This case reminds us that early recognition of acute coronary obstruction and prompt intervention are crucial in patients with aortic stenosis who have undergone transcatheter aortic valve replacement.

  18. First-in-Man Computed Tomography-Guided Percutaneous Revascularization of Coronary Chronic Total Occlusion Using a Wearable Computer: Proof of Concept.

    Science.gov (United States)

    Opolski, Maksymilian P; Debski, Artur; Borucki, Bartosz A; Szpak, Marcin; Staruch, Adam D; Kepka, Cezary; Witkowski, Adam

    2016-06-01

    We report a case of successful computed tomography-guided percutaneous revascularization of a chronically occluded right coronary artery using a wearable, hands-free computer with a head-mounted display worn by interventional cardiologists in the catheterization laboratory. The projection of 3-dimensional computed tomographic reconstructions onto the screen of virtual reality glass allowed the operators to clearly visualize the distal coronary vessel, and verify the direction of the guide wire advancement relative to the course of the occluded vessel segment. This case provides proof of concept that wearable computers can improve operator comfort and procedure efficiency in interventional cardiology. Copyright © 2016 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  19. Quantitative thallium-201 single-photon emission computed tomography during maximal pharmacologic coronary vasodilation with adenosine for assessing coronary artery disease

    International Nuclear Information System (INIS)

    Nishimura, S.; Mahmarian, J.J.; Boyce, T.M.; Verani, M.S.

    1991-01-01

    The diagnostic value of maximal pharmacologic coronary vasodilation with intravenously administered adenosine in conjunction with thallium-201 single-photon emission computed tomography (SPECT) for detection of coronary artery disease was investigated in 101 consecutive patients who had concomitant coronary arteriography. Tomographic images were assessed visually and from computer-quantified polar maps of the thallium-201 distribution. Significant coronary artery disease, defined as greater than 50% luminal diameter stenosis, was present in 70 patients. The sensitivity for detecting patients with coronary artery disease using quantitative analysis was 87% in the total group, 82% in patients without myocardial infarction and 96% in those with prior myocardial infarction; the specificity was 90%. The sensitivity for diagnosing coronary artery disease in patients without infarction with single-, double-and triple-vessel disease was 76%, 86% and 90%, respectively. All individual stenoses were identified in 68% of patients with double-vessel disease and in 65% of those with triple-vessel disease. The extent of the perfusion defects, as quantified by polar maps, was directly related to the extent of coronary artery disease. In conclusion, quantitative thallium-201 SPECT during adenosine infusion has high sensitivity and specificity for diagnosing the presence of coronary artery disease, localizing the anatomic site of coronary stenosis and identifying the majority of affected vascular regions in patients with multivessel involvement

  20. Comparison of Myocardial Perfusion Scintigraphy and Coronary Angiography Results

    Directory of Open Access Journals (Sweden)

    Umut Elboga

    2017-05-01

    Full Text Available Aim: Coronary artery disease (CAD is one of the most frequent causes of mortality and morbidity worldwide. Coronary angiography is the gold standard for the anatomical diagnosis of coronary artery stenosis. Myocardial Perfusion Scintigraphy (MPS is a non-invasive imaging modality used for the diagnosis of CAD. In this study, we aimed to compare the findings of MPS and coronary angiogram. Material and Method: Eighty-one patients (37 males, 44 females; mean age 55 ± 10.95 years with angina and detected perfusion defects on MPS were included in this study. All of the patients underwent coronary angiogram. A narrowing %u2265 50% was considered pathological on the coronary angiography. Results: Findings of the coronary angiogram and MPS were compared and found consistent in 51 (63% patients. A coronary narrowing < 50% was detected by coronary angiogram in 4 (5% of the remaining patients. Coronary angiogram was found to be normal in the remaining 26 patients (32% and these patients were evaluated as cardiac syndrome X (CSX known as microvascular angina (MA. Discussion: The findings showed that MPS is superior to coronary angiogram in the early diagnosis of myocardial perfusion disorders at the microvascular level. Therefore, we concluded that MPS should be the primary diagnostic tool to begin treatment before an anatomically large narrowing occurs in the coronaries.