WorldWideScience

Sample records for corneal opacity

  1. Pentacam-based phototherapeutic keratectomy outcome in superficial corneal opacities

    Directory of Open Access Journals (Sweden)

    Rashad MA

    2012-06-01

    Full Text Available Mohammad A RashadOphthalmology Department, Faculty of Medicine, Ain Shams University, Cairo, EgyptPurpose: This study aimed to evaluate the effectiveness of phototherapeutic keratectomy (PTK as an alternative treatment to keratoplasty using the Pentacam to assess depth of dense opacities.Methodology: PTK was performed in eleven eyes of ten patients with superficial corneal opacities after assessment by Scheimpflug images of the Pentacam for central corneal thickness (CCT and opacity level and depth.Results: The best-corrected spectacle visual acuity (BCSVA significantly improved. The preoperative mean logMAR was 0.85 (0.14 decimal equivalent, 6/42 Snellen's equivalent, and the final postoperative mean logMAR was 0.58 (0.26 decimal equivalent, 6/23 Snellen's equivalent. The mean preoperative CCT was 465.64 ± 71.94 µm. The mean programmed ablation depth was 142.09 ± 47.58 µm. The programmed ablation depth was correlated to mean logMAR early (1 month and not correlated later (6 months. None of the eyes lost lines of BCSVA or developed serious complications, such as keratectasia, delayed epithelialization, or corneal melting.Conclusion: Corneal scars extending beyond the anterior one-fifth of the cornea can be treated safely and effectively by PTK due to the smoothing effect, with reduction of the cylinder rather than complete opacity removal. This can decrease the need for keratoplasty.Keywords: phototherapeutic keratectomy, PTK, corneal opacities, Pentacam

  2. Image Analysis on Corneal Opacity:A Novel Method to Estimate Postmortem Interval in Rabbits

    Institute of Scientific and Technical Information of China (English)

    周兰; 刘艳; 刘良; 卓荦; 梁曼; 杨帆; 任亮; 朱少华

    2010-01-01

    Corneal opacity is one of the most commonly used parameters for estimating postmortem interval(PMI).This paper proposes a new method to study the relationship between changes of corneal opacity and PMI by processing and analyzing cornea images.Corneal regions were extracted from images of rabbits' eyes and described by color-based and texture-based features,which could represent the changes of cornea at different PMI.A KNN classifier was used to reveal the association of image features and PMI.The result of...

  3. Femtosecond laser-assisted keratoplasty in a child with corneal opacity:case report

    Directory of Open Access Journals (Sweden)

    E. Yu. Markova

    2014-01-01

    Full Text Available Corneal opacities are the fourth cause of blindness world-wide. Over the past two centuries, various corneal transplantation (i.e., keratoplasty methods have been developed and improved. Nowadays, femtolaserssisted keratoplasty is one of most promising techniques. Femtosecond laser have several advantages that provide additional surgical benefits. Among them, no thermal injury, the ability to cut deeply on a single plane and to perform various corneal profiles should be mentioned. In children, corneal disorders are of special importance while femtosecondassisted keraatoplasty case reports are rare. Here, we describe femtosecond laserssisted penetrating keratoplasty in a girl with a rough central corneal opacity.

  4. A novel congenital ichthyosiform syndrome with associated panhypopituitarism, corneal opacities and mental retardation.

    Science.gov (United States)

    Pandhi, Deepika; Khanna, Deepshikha; Singal, Archana; Madhu, Sri Venkata

    2007-11-01

    A 15-year-old male presented with ichthyosis since infancy with panhypopituitarism, short stature and knock-knees, delayed puberty, high scrotal retractile testes, mental retardation and corneal opacities. He developed recurrent tinea capitis and tinea corporis. The clinical symptomatology indicates that this case cannot be considered as a subtype of inherited ichthyosis group, but suggests a new syndrome as a separate nosologic entity. Two previously reported cases with possibly the same syndrome also had ichthyosis associated with variable endocrinopathy. Thorough endocrinological evaluation and appropriate intervention in patients of ichthyosis with short stature may reduce the morbidity associated with retarded skeletal growth and gonadal maturation.

  5. Opacity

    CERN Document Server

    Huebner, Walter F

    2014-01-01

    The interaction of radiation with matter is a fundamental process in the universe; in particular, the absorption and scattering of radiation by matter (the opacity) govern the formation, evolution, and structure of stars and planets.  But opacity is also important in many terrestrial applications in which radiation is the dominant means of energy transfer, such as controlled nuclear-fusion, laser ablation, atmospheric entry and reentry, and the "greenhouse" effect.  This book covers all aspects of opacity and equations of state for plasmas, gases, vapors, and dust and emphasizes the continuous transformation of phases and molecular compositions with changing density and temperature under conditions of local thermodynamic equilibrium (LTE) while preserving the basic abundances of the chemical elements in a mixture.

  6. Effects of Silicone Hydrogel Contact Lens Application on Corneal High-order Aberration and Visual Guality in Patients with Corneal Opacities

    Directory of Open Access Journals (Sweden)

    Sevda Aydın Kurna

    2012-03-01

    Full Text Available Pur po se: Evaluation of the corneal high-order aberrations and visual quality changes after application of silicone hydrogel contact lenses in patients with corneal opacities due to various etiologies. Ma te ri al and Met hod: Fifteen eyes of 13 patients with corneal opacities were included in the study. During the ophthalmologic examination before and after contact lens application, visual acuity was measured with Snellen acuity chart and contrast sensitivity - with Bailey-Lowie Charts in letters. Aberrations were measured with corneal aberrometer (NIDEK Magellan Mapper under a naturally dilated pupil. Spherical aberration, coma, trefoil, irregular astigmatism and total high-order root mean square (RMS values were recorded. Measurements were repeated with balafilcon A lenses (PureVision 2 HD, B&L on all patients. Re sults: Patient age varied between 23 and 50 years. Two eyes had subepithelial infiltrates due to adenoviral keratitis, 1 had nebulae due to previous infections or trauma, and 2 had Salzmann’s nodular degeneration. We observed a mean increase of 1 line in visual acuity and 5 letters in contrast sensitivity with contact lenses versus glasses in the patients. Mean RMS values of spherical aberration, irregular astigmatism and total high-order aberrations decreased significantly with contact lenses. Dis cus si on: Silicone hydrogel soft contact lenses may improve visual quality by decreasing the corneal aberrations in patients with corneal opacities. (Turk J Ophthalmol 2012; 42: 97-102

  7. Improvement of the Bovine Corneal Opacity and Permeability (BCOP) assay as an in vitro alternative to the Draize rabbit eye irritation test.

    Science.gov (United States)

    Verstraelen, Sandra; Jacobs, An; De Wever, Bart; Vanparys, Philippe

    2013-06-01

    Measurement of ocular irritancy is a necessary step in the safety evaluation of both industrial and consumer products. Assessment of the acute eye irritation potential is therefore part of the international regulatory requirements for testing of chemicals. The Bovine Corneal Opacity and Permeability (BCOP) assay is generally accepted as a valid in vitro alternative method to the Draize eye irritation test to detect corrosive and severe eye irritants (category 1), but has not proven sensitive enough to discriminate accurately moderate (category 2A/2B) to mild and non-irritating compounds. In the currently accepted BCOP assay, opacity is determined by the amount of light transmission through the cornea, and permeability is determined by the amount of sodium fluorescein dye that passes through all corneal cell layers. Both measurements are used to assign an In Vitro Irritancy Score (IVIS) for prediction of the in vivo ocular irritation potential of a test substance. Nowadays, opacity is measured by an OP-KIT opacitometer providing a center-weighted reading of light transmission by measuring changes in voltage when the transmission of white light passes through the cornea alters. As a consequence, this may underestimate opacity that develops as spots or heterogeneous opaque areas on the periphery of an isolated cornea. A prototype of a laser light-based opacitometer (PLLBO) allowing better measurement of opacities was developed by Van Goethem et al. (2010). This new device showed improved sensitivity to detect subtle changes in corneal transparency. Furthermore, the new opacitometer allowed the analysis of the complete corneal surface and was able to detect more efficiently opaque spots located along the sides of the excised corneas. A further improved prototype of the PLLBO was constructed in combination with a camera and a speckle noise reducer. Treatment conditions of the corneas in the cornea holders were optimized in order to mimic more the real in vivo situation

  8. Multilevel Analysis of Trachomatous Trichiasis and Corneal Opacity in Nigeria: The Role of Environmental and Climatic Risk Factors on the Distribution of Disease.

    Directory of Open Access Journals (Sweden)

    Jennifer L Smith

    Full Text Available The distribution of trachoma in Nigeria is spatially heterogeneous, with large-scale trends observed across the country and more local variation within areas. Relative contributions of individual and cluster-level risk factors to the geographic distribution of disease remain largely unknown. The primary aim of this analysis is to assess the relationship between climatic factors and trachomatous trichiasis (TT and/or corneal opacity (CO due to trachoma in Nigeria, while accounting for the effects of individual risk factors and spatial correlation. In addition, we explore the relative importance of variation in the risk of trichiasis and/or corneal opacity (TT/CO at different levels. Data from the 2007 National Blindness and Visual Impairment Survey were used for this analysis, which included a nationally representative sample of adults aged 40 years and above. Complete data were available from 304 clusters selected using a multi-stage stratified cluster-random sampling strategy. All participants (13,543 individuals were interviewed and examined by an ophthalmologist for the presence or absence of TT and CO. In addition to field-collected data, remotely sensed climatic data were extracted for each cluster and used to fit Bayesian hierarchical logistic models to disease outcome. The risk of TT/CO was associated with factors at both the individual and cluster levels, with approximately 14% of the total variation attributed to the cluster level. Beyond established individual risk factors (age, gender and occupation, there was strong evidence that environmental/climatic factors at the cluster-level (lower precipitation, higher land surface temperature, higher mean annual temperature and rural classification were also associated with a greater risk of TT/CO. This study establishes the importance of large-scale risk factors in the geographical distribution of TT/CO in Nigeria, supporting anecdotal evidence that environmental conditions are associated

  9. Medicinal management of corneal opacity in free ranging rhesus macaques (Macaca mulatta of Shivalik hills in Western Himalayas, Northern India

    Directory of Open Access Journals (Sweden)

    V. Kumar

    2015-05-01

    Full Text Available Corneal opacification was diagnosed in 17 free ranging rhesus macaques during detailed ophthalmic examination as a part of clinical health examination, at the monkey rescue sterilization centre in Hamirpur Himachal Pradesh, India. The cornea was completely opaque permitting only a little vision with respect to the affected eye. Medical management with topical ciprofloxacin and prednisolone along with ketoprofen and vitamin A was instituted. The corneal lesions subsided completely within one week following treatment. The treatment protocol successfully eliminated the discomfort and intraocular lesions with no serious subsequent irritation due to the treatment in these animals.

  10. Comparison of in vitro eye irritation potential by bovine corneal opacity and permeability (BCOP) assay to erythema scores in human eye sting test of surfactant-based formulations.

    Science.gov (United States)

    Cater, Kathleen C; Harbell, John W

    2008-01-01

    The bovine corneal opacity and permeability (BCOP) assay can be used to predict relative eye irritation potential of surfactant-based personal care formulations relative to a corporate benchmark. The human eye sting test is typically used to evaluate product claims of no tears/no stinging for children's bath products. A preliminary investigation was conducted to test a hypothesis that the BCOP assay could be used as a prediction model for relative ranking of human eye irritation responses under conditions of a standard human eye sting test to surfactant-based formulations. BCOP assays and human eye sting tests were conducted on 4 commercial and 1 prototype body wash (BW) developed specifically for children or as mild bath products. In the human eye sting test, 10 mul of a 10% dosing solution is instilled into one eye of each panelist (n = 20), and the contralateral eye is dosed with sterile water as a control. Bulbar conjunctival erythema responses of each eye are graded at 30 seconds by an ophthalmologist. The BCOP assay permeability values (optical density at 490 nm [OD(490)]) for the 5 BWs ranged from 0.438 to 1.252 (i.e., least to most irritating). By comparison, the number of panelists exhibiting erythema responses (mild to moderately pink) ranged from 3 of 20 panelists for the least irritating BW to 10 of 20 panelists for the most irritating BW tested. The relative ranking of eye irritation potential of the 5 BWs in the BCOP assay compares favorably with the relative ranking of the BWs in the human eye sting test. Based on these findings, the permeability endpoint of the BCOP assay, as described for surfactant-based formulations, showed promise as a prediction model for relative ranking of conjunctival erythema responses in the human eye. Consequently, screening of prototype formulations in the BCOP assay would allow for formula optimization of mild bath products prior to investment in a human eye sting test.

  11. SURGICAL OUTCOME OF TRIPLE PROCEDURE AS PENETRATING KERATOPLASTY WITH EXTRACAPSULAR CATARACT EXTRACTION WITH POSTERIOR CHAMBER INTRAOCULAR LENS IMPLANTATION IN PATIENTS WITH BOTH CENTRAL CORNEAL OPACITY AND ADVANCED CATARACT AT RURAL SET UP

    Directory of Open Access Journals (Sweden)

    Shubhangi Nigwekar, Kishor Badhe, Neeta Misra, Surekha Bangal

    2015-10-01

    Full Text Available Purpose: To study the surgical outcome of triple procedure as penetrating keratoplasty (PKP with conventional extra capsular cataract extraction (ECCE with posterior chamber intraocular lens (PCIOL implantation in patients with both central corneal opacity and advanced cataract at rural set up. Introduction: When corneal opacity and cataract present together then well-established and effective triple procedure is indicated. Prognosis for a clear graft is good in triple, as graft endothelium does not touch the hard nucleus which may occur in two steps or sequential surgery. It provides faster visual rehabilitation. Being single step procedure it reduces patient’s hospital stay, postoperative care and follows up visits. Methodology: In this hospital based observational , three years longitudinal study, we studied the surgical outcome of relatively rare one step triple procedure as PKP with conventional ECCE with PCIOL implantation in sulcus or in bag, in patients with both central corneal opacity and advanced cataract at rural set up. The outcome measures included graft clarity on slit lamp, postoperative unaided visual acuity with Snellen’s chart and the occurrence of postoperative complications after taking IEC permission and informed written consent in local language from study patients. Results: Out of 13 study patients mean age was 61.15yrs (Range50-80yrs. Follow up range was 9-34 months. At final follow up 9 patients (69.23% had clear grafts and 61.52% patients gained visual acuity >6/24. Graft failure was the most common post operative complication in 30.76% followed by Posterior capsular opacification (PCO in 15.38% patients which was treated well with YAG laser capsulotomy. Conclusion: Triple procedure gives good results in respect to graft clarity, unaided vision, and faster rehabilitation.

  12. Clinical application of ultrasound biomicroscopy in the treatment of congenital corneal opacities%超声生物显微镜在先天性角膜混浊诊疗中的应用价值

    Institute of Scientific and Technical Information of China (English)

    李东芳; 赵军; 李滢; 臧新杰; 应良

    2012-01-01

    Objective To investigate the clinical application of ultrasound biomicroscopy in the treatment of congenital corneal opacities.Methods Medical records of 20 eyes (15 patients) with congenital corneal opacity treated at our hospital from July 2004 to November 2011 were retrospectively reviewed.Best corrected visual acuity testing,intraocular pressure testing,slit-lamp anterior segment examination,fundus examination,slit-lamp microscopic photography,B scan examination,and ultrasound biomicroscopy were performed for analysis of complications of congenital corneal opacity and selection of surgical approaches.Results The ultrasound biomicroscopic examination showed that 5 eyes had no Descemet's membrane and corneal endothelium,20 eyes had anterior synechia,5 eyes had aniridia,3 eyes had loss of lens cortex,13 eyes had cataract,14 eyes had closed angle,and 3 eyes had pupillary membrane.14 of 20 eyes received surgical treatment,including penetrating keratoplasty combined with cataract extraction and trabeculectomy (5 eyes),penetrating keratoplasty combined with pupil angioplasty (3 eyes),penetrating keratoplasty combined with cataract extraction (3 eyes),penetrating keratoplasty combined with trabeculectomy (2 eyes),and lamellar keratoplasty (1 eye).Conclusions Ultrasound biomicroscopy is important to guide the diagnosis and treatment of congenital corneal opacity.%目的 探讨超声生物显微镜在治疗先天性角膜混浊的临床应用.方法 回顾分析2004年7月至2011年11月于我院收治的先天性角膜混浊患者15例20只眼,常规行最佳矫正视力检查、眼压检查、裂隙灯眼前节检查、眼底检查、大体照相、B型超声检查、超声生物显微镜检查,分析先天性角膜混浊的并发症及手术方式情况.结果 根据超声生物显微镜检查结果,先天性角膜混浊患者伴有角膜无后弹力膜和内皮层者5只眼,虹膜前粘连(Peter异常)者20只眼,虹膜缺损者5只眼,晶体皮质丢失者3

  13. Stellar Opacity

    Energy Technology Data Exchange (ETDEWEB)

    Rogers, F J; Iglesias, C A

    1999-11-07

    The monochromatic opacity, {kappa}{sub v}, quantifies the property of a material to remove energy of frequency v from a radiation field. A harmonic average of {kappa}{sub v}, known as the Rosseland mean, {kappa}{sub R}, is frequently used to simplify the calculation of energy transport in stars. The term ''opacity'' is commonly understood to refer to {kappa}{sub R}. Opacity plays an important role in stellar modeling because for most stars radiation is the primary mechanism for transporting energy from the nuclear burning region in the core to the surface. Depending on the mass, convection and electron thermal conduction can also be important modes of stellar energy transport. The efficiency of energy transport is related to the temperature gradient, which is directly proportional to the mean radiative opacity in radiation dominated regions. When the radiative opacity is large, convection can become the more efficient energy transport mechanism. Electron conductive opacity, the resistance of matter to thermal conduction, is inversely proportional to electron thermal conductivity. Thermal conduction becomes the dominant mode of energy transport at high density and low temperature.

  14. Research on bovine corneal opacity and permeability test integrating with histopathological evaluation%结合组织学评分的牛角膜浑浊和渗透性方法研究

    Institute of Scientific and Technical Information of China (English)

    陈彧; 喻欢; 程树军; 谈伟君; 秦瑶

    2016-01-01

    为了优化替代眼刺激动物试验的牛角膜浑浊和渗透性(BCOP)实验的方法,提高其适用范围和预测性,选取新鲜牛眼角膜,直接暴露液体化学受试物作用10 min,后孵育2 h并用荧光素钠处理90 min,采用浊度仪检测角膜浑浊度,用酶标仪检测荧光素钠渗透性,同时将角膜常规固定和制备组织学切片,观察组织学病理变化并评分,基于上述3个指标建立预测模型。结果显示,将角膜浑浊度和渗透性2个定量指标,与角膜上皮组织、基质组织和内皮细胞的组织学变化评分进行组合,可对轻微刺激到中等刺激的范围进行准确细分。研究表明,结合组织学观察的优化BCOP方法可提高其预测性,适用于眼刺激机制研究和化妆品评估。%In order to refine the alternative method for animal eye irritation test———the bovine corneal opacity and permeability (BCOP)test,and to enhance its application scope and predictability,the fresh bovine corneas were chosen and directly exposed to liquid chemical material to be tested for 10 min,post - incubated for 2 h and further treated with fluorescein sodium for 90 min. Then opacity of the treated corneas was measured with opacitometer;the permeability was determined with the multiskan spectrum microplate spectrophotometer and the histopathological changes of the cornea were observed and graded after routinely fixed and paraffin embedding. Finally,the predictive models based on the above three indices were established. The results showed that the corneal opacity and permeability,integrated with histopathological changes of epithelium, stroma and endothelium,the scope of irritation from mild level to moderate level can be accurately distinguished. In conclusion,the refined BCOP method integrated with histological observation could improve its predictability and suitable for study of eye irritation mechanism and cosmetic product evaluation.

  15. Survey of ocular irritation predictive capacity using Chorioallantoic Membrane Vascular Assay (CAMVA) and Bovine Corneal Opacity and Permeability (BCOP) test historical data for 319 personal care products over fourteen years.

    Science.gov (United States)

    Donahue, D A; Kaufman, L E; Avalos, J; Simion, F A; Cerven, D R

    2011-03-01

    The Chorioallantoic Membrane Vascular Assay (CAMVA) and Bovine Corneal Opacity and Permeability (BCOP) test are widely used to predict ocular irritation potential for consumer-use products. These in vitro assays do not require live animals, produce reliable predictive data for defined applicability domains compared to the Draize rabbit eye test, and are rapid and inexpensive. Data from 304 CAMVA and/or BCOP studies (319 formulations) were surveyed to determine the feasibility of predicting ocular irritation potential for various formulations. Hair shampoos, skin cleansers, and ethanol-based hair styling sprays were repeatedly predicted to be ocular irritants (accuracy rate=0.90-1.00), with skin cleanser and hair shampoo irritation largely dependent on surfactant species and concentration. Conversely, skin lotions/moisturizers and hair styling gels/lotions were repeatedly predicted to be non-irritants (accuracy rate=0.92 and 0.82, respectively). For hair shampoos, ethanol-based hair stylers, skin cleansers, and skin lotions/moisturizers, future ocular irritation testing (i.e., CAMVA/BCOP) can be nearly eliminated if new formulations are systematically compared to those previously tested using a defined decision tree. For other tested product categories, new formulations should continue to be evaluated in CAMVA/BCOP for ocular irritation potential because either the historical data exhibit significant variability (hair conditioners and mousses) or the historical sample size is too small to permit definitive conclusions (deodorants, make-up removers, massage oils, facial masks, body sprays, and other hair styling products). All decision tree conclusions should be made within a conservative weight-of-evidence context, considering the reported limitations of the BCOP test for alcohols, ketones, and solids.

  16. Ocular dimensions, corneal thickness, and corneal curvature in quarter horses with hereditary equine regional dermal asthenia.

    Science.gov (United States)

    Badial, Peres R; Cisneros-Àlvarez, Luis Emiliano; Brandão, Cláudia Valéria S; Ranzani, José Joaquim T; Tomaz, Mayana A R V; Machado, Vania M; Borges, Alexandre S

    2015-09-01

    The aim of this study was to compare ocular dimensions, corneal curvature, and corneal thickness between horses affected with hereditary equine regional dermal asthenia (HERDA) and unaffected horses. Five HERDA-affected quarter horses and five healthy control quarter horses were used. Schirmer's tear test, tonometry, and corneal diameter measurements were performed in both eyes of all horses prior to ophthalmologic examinations. Ultrasonic pachymetry was performed to measure the central, temporal, nasal, dorsal, and ventral corneal thicknesses in all horses. B-mode ultrasound scanning was performed on both eyes of each horse to determine the dimensions of the ocular structures and to calculate the corneal curvature. Each corneal region examined in this study was thinner in the affected group compared with the healthy control group. However, significant differences in corneal thickness were only observed for the central and dorsal regions. HERDA-affected horses exhibited significant increases in corneal curvature and corneal diameter compared with unaffected animals. The ophthalmologic examinations revealed mild corneal opacity in one eye of one affected horse and in both eyes of three affected horses. No significant between-group differences were observed for Schirmer's tear test, intraocular pressure, or ocular dimensions. Hereditary equine regional dermal asthenia-affected horses exhibit decreased corneal thickness in several regions of the cornea, increased corneal curvature, increased corneal diameter, and mild corneal opacity. Additional research is required to determine whether the increased corneal curvature significantly impacts the visual accuracy of horses with HERDA. © 2014 American College of Veterinary Ophthalmologists.

  17. Production of a corneal opacity mouse by N-ethyl-N-nitrosourea mutagenesis and chromosome mapping of the mutant gene%乙酰基亚硝基脲诱变的一种角膜混浊小鼠及其突变基因的染色体定位

    Institute of Scientific and Technical Information of China (English)

    陈兵; 糜婷; 倪俊达; 耿滕; 薛整风

    2014-01-01

    背景 乙酰基亚硝基脲(ENU)诱导小鼠基因突变是研究基因功能及建立人类疾病动物模型的一种有效手段. 目的 研究ENU诱变获得的1只角膜混浊小鼠角膜组织形态变化,并对其突变基因进行染色体定位.方法 选用8~10周龄的C57BL/6J (B6)雄鼠40只,腹腔内注射ENU.将注射后的雄鼠与同品系母鼠交配,在其后代小鼠中筛选眼部突变个体,并将突变个体与同品系小鼠配种以确定是否遗传.对ENU诱变获得1只角膜混浊小鼠的角膜行组织病理学观察.繁殖[(B6×D2) F1×B6] N2角膜混浊小鼠,用平均分布于小鼠染色体上的微卫星标记对N2小鼠染色体进行扫描.采用优势对数计分法(LOD)判定突变基因与微卫星是否连锁. 结果 将角膜呈现混浊小鼠与B6背景小鼠配种,在其59只后代中出现19只类似表型的突变小鼠.角膜组织病理学检查发现,该例角膜混浊小鼠角膜基质增厚,出现新生血管和炎性细胞浸润,成纤维细胞明显增多.突变基因与微卫星间的连锁分析发现,26个N2样品中突变基因与位于小鼠2号染色体63.42 cM处的D2Mi307位点发生3例交换,LOD值为3.79,该突变基因位于小鼠第2号染色体. 结论 成功获得角膜混浊小鼠并将其突变基因初步定位于2号染色体,有望为人类角膜混浊疾病研究提供一种新的小鼠模型.%Background N-ethyl-N-nitrosourea (ENU)-induced mouse mutagenesis is a powerful approach for the study of gene function and the generation of human disease models.Objective This study was to create the corneal morphologic change and map the mutant gene of a kind of corneal opacity in ENU mutagenesis in mouse.Methods ENU was intraperitoneally injected in forty C57BL/ 6J (B6) male mice aged 8-10 weeks old.The male mice were mated with the same strain female mice.Their progenies were screened for visible eye mutation,and the mutant mice were mated with the same strain mice to confirm the heredity of

  18. Corneal Laceration

    Medline Plus

    Full Text Available ... Laceration? Corneal Laceration Diagnosis Corneal Laceration Treatment What Is Corneal Laceration? Written By: Daniel Porter Reviewed By: ... A Harrison MD Sep. 01, 2016 The cornea is the clear front window of the eye . A ...

  19. Universe opacity and EBL

    CERN Document Server

    Vavrycuk, Vaclav

    2016-01-01

    The observed extragalactic background light (EBL) is affected by light attenuation due to absorption of light by galactic and intergalactic dust in the Universe. Even galactic opacity of 10-20 percent and minute universe intergalactic opacity of $0.01\\,\\mathrm{mag}\\,h\\,\\mathrm{Gpc}^{-1}$ at the local Universe have a significant impact on the EBL because obscuration of galaxies and density of intergalactic dust increase with redshift as $\\left(1+z\\right)^3$. Consequently, intergalactic opacity increases and the Universe becomes considerably opaque at $z > 3$. Adopting realistic values for galactic and intergalactic opacity, the estimates of the EBL for the expanding dusty universe are close to observations. The luminosity density evolution fits well measurements. The model reproduces a steep increase of the luminosity density at $z3.5$.

  20. [Regeneration and fibrosis of corneal tissues].

    Science.gov (United States)

    Simirskiĭ, V N

    2014-01-01

    In this review, the features of the regeneration of corneal tissue and its disorders leading to the development of fibrosis are considered. The data on the presence of stem (clonogenic) cell pool in the corneal tissues (epithelium, endothelium, stroma) are given; these cells can serve as a source for regeneration of the tissues at injury or various diseases. The main steps of regeneration of corneal tissues and their disorders that lead to outstripping proliferation of myofibroblasts and secretion of extracellular matrix in the wound area and eventually cause the formation of connective tissue scar and corneal opacity are considered. Particular attention is given to the successes of translational medicine in the treatment of corneal tissue fibrosis. The methods of cell therapy aimed at the restoration of stem cell pool of corneal tissues are the most promising. Gene therapy provides more opportunities; one of its main objectives is the suppression of the myofibroblast proliferation responsible for the development of fibrosis.

  1. Gelatinous drop-like corneal dystrophy: a review.

    Science.gov (United States)

    Kaza, Hrishikesh; Barik, Manas R; Reddy, Mamatha M; Mittal, Ruchi; Das, Sujata

    2017-01-01

    Gelatinous drop-like corneal dystrophy (GDLD) is a rare autosomal recessive form of corneal dystrophy characterised by subepithelial and stromal amyloid deposits. It is relatively common in Japan. It usually presents in the first two decades of life with subepithelial nodular lesions that later coalesce to form mulberry-like opacities. Although various surgical modalities have been attempted, recurrence remains a major challenge.

  2. Corneal Laceration

    Medline Plus

    Full Text Available ... your vision. Privacy Policy Related People with Advanced Keratoconus May Have A Future Alternative to Full Corneal ... 2016 Corneal Collagen Cross-linking Approved to Treat Keratoconus in U.S. Aug 01, 2016 Firework Blinds Teenager, ...

  3. Corneal Laceration

    Medline Plus

    Full Text Available ... lost sight from a corneal scar as a child. Now that I’m older, will a corneal transplant help me? May 15, 2015 Why Do My Eyes Burn After Inserting My Contacts? Feb 27, 2015 Dark ...

  4. Corneal Abrasions

    Science.gov (United States)

    ... and lead to a serious condition called a corneal ulcer . That's why it's important to see a doctor to get a corneal abrasion checked out. What Causes a Corneal ... and land on your cornea, tears help to wash the particles away. Sometimes, ...

  5. [Glycosaminoglycans in subepithelial opacity after excimer laser keratectomy].

    Science.gov (United States)

    Nakayasu, K; Gotoh, T; Ishikawa, T; Kanai, A

    1996-05-01

    We evaluated histochemically the characteristics of glycosaminoglycans and proteoglycans in the corneal subepithelial opacity after excimer laser keratectomy on rabbit corneas. We also performed the same evaluations on the cornea after mechanical keratectomy. Twenty days after the operations, the area immediately subjacent to the epithelium showed strong staining with toluidine blue, alcian blue, and colloidal iron. However, after treatment with chondroitinase ABC or chondroitinase AC, alcian blue staining in this area decreased dramatically. Antilarge proteoglycan antibody also reacted strongly in this area. Histochemical and immunohistochemical examination of the cornea where mechanical keratectomy was done showed basically similar findings with the cornea of excimer laser keratectomy. These results suggest that large-molecula proteoglycans with chondroitine sulfate side chains become localized in the subepithelial area after two different kinds of keratectomies. We presume from histochemical and immunohistochemical observations that the subepithelial opacity observed after excimer laser keratectomy is not a special reaction to excimer laser but simply a corneal scar formed after stromal resection.

  6. Universe opacity and EBL

    Science.gov (United States)

    Vavryčuk, Václav

    2017-02-01

    The observed extragalactic background light (EBL) is affected by light attenuation due to absorption of light by galactic and intergalactic dust in the Universe. Even galactic opacity of 10-20 per cent and minute universe intergalactic opacity of 0.01 mag h Gpc-1 at the local Universe have a significant impact on the EBL because obscuration of galaxies and density of intergalactic dust increase with redshift as (1 + z)3. Consequently, intergalactic opacity increases and the Universe becomes considerably opaque at z > 3. Adopting realistic values for galactic and intergalactic opacity, the estimates of the EBL for the expanding dusty universe are close to observations. The luminosity density evolution fits well measurements. The model reproduces a steep increase of the luminosity density at z EBL ranges from 100 to 200 nW m-2 sr-1 and is within the limits of 40 and 200 nW m-2 sr-1 of current EBL observations. The model predicts 98 per cent of the EBL coming from radiation of galaxies at z 3.5.

  7. Overapplication opacity in phonological acquisition

    Directory of Open Access Journals (Sweden)

    Olga Urek

    2013-02-01

    Full Text Available Normal 0 false false false EN-US JA X-NONE Phonological opacity is a challenge for parallel OT, which does not allow for intermediate levels of representation. Several modifications of the theory have been proposed over the years to incorporate opacity, all of them falling short of accounting for spontaneous opacity effects in developing grammars. In this paper I demonstrate that if certain independently motivated adjustments are made to the recent OT-based theory of opacity called Optimality Theory with Candidate Chains (OT-CC, see McCarthy 2007, it can successfully deal with spontaneous opacity effects.

  8. Molecular opacities for exoplanets.

    Science.gov (United States)

    Bernath, Peter F

    2014-04-28

    Spectroscopic observations of exoplanets are now possible by transit methods and direct emission. Spectroscopic requirements for exoplanets are reviewed based on existing measurements and model predictions for hot Jupiters and super-Earths. Molecular opacities needed to simulate astronomical observations can be obtained from laboratory measurements, ab initio calculations or a combination of the two approaches. This discussion article focuses mainly on laboratory measurements of hot molecules as needed for exoplanet spectroscopy.

  9. Corneal Laceration

    Science.gov (United States)

    ... drugs. These drugs thin the blood and may increase bleeding. After you have finished protecting the eye, see a physician immediately. Next Corneal Laceration Symptoms Related Ask an Ophthalmologist Answers I lost sight from a corneal scar as a child. Now that I’m older, ...

  10. Corneal Laceration

    Medline Plus

    Full Text Available ... Tips & Prevention News Ask an Ophthalmologist Patient Stories Español Eye Health / Eye Health A-Z Corneal Laceration ... Laceration Treatment What Is Corneal Laceration? Leer en Español: ¿Qué Es una Laceración de la Córnea? Written ...

  11. Corneal Laceration

    Medline Plus

    Full Text Available ... Health Find an Ophthalmologist Academy Store Eye Health A-Z Symptoms Glasses & Contacts Tips & Prevention News Ask ... Ophthalmologist Patient Stories Español Eye Health / Eye Health A-Z Corneal Laceration Sections What Is Corneal Laceration? ...

  12. Corneal Laceration

    Medline Plus

    Full Text Available ... Health Find an Ophthalmologist Academy Store Eye Health A-Z Symptoms Glasses & Contacts Tips & Prevention News Ask ... Ophthalmologist Patient Stories Español Eye Health / Eye Health A-Z Corneal Laceration Sections What Is Corneal Laceration? ...

  13. The molecular genetics of the corneal dystrophies--current status.

    Science.gov (United States)

    Klintworth, Gordon K

    2003-05-01

    The pertinent literature on inherited corneal diseases is reviewed in terms of the chromosomal localization and identification of the responsible genes. Disorders affecting the cornea have been mapped to human chromosome 1 (central crystalline corneal dystrophy, familial subepithelial corneal amyloidosis, early onset Fuchs dystrophy, posterior polymorphous corneal dystrophy), chromosome 4 (Bietti marginal crystalline dystrophy), chromosome 5 (lattice dystrophy types 1 and IIIA, granular corneal dystrophy types 1, 2 and 3, Thiel-Behnke corneal dystrophy), chromosome 9 (lattice dystrophy type II), chromosome 10 (Thiel-Behnke corneal dystrophy), chromosome 12 (Meesmann dystrophy), chromosome 16 (macular corneal dystrophy, fish eye disease, LCAT disease, tyrosinemia type II), chromosome 17 (Meesmann dystrophy, Stocker-Holt dystrophy), chromosome 20 (congenital hereditary endothelial corneal dystrophy types I and II, posterior polymorphous corneal dystrophy), chromosome 21 (autosomal dominant keratoconus) and the X chromosome (cornea verticillata, cornea farinata, deep filiform corneal dystrophy, keratosis follicularis spinulosa decalvans, Lisch corneal dystrophy). Mutations in nine genes (ARSC1, CHST6, COL8A2, GLA, GSN, KRT3, KRT12, M1S1and TGFBI [BIGH3]) account for some of the corneal diseases and three of them are associated with amyloid deposition in the cornea (GSN, M1S1, TGFBI) including most of the lattice corneal dystrophies (LCDs) [LCD types I, IA, II, IIIA, IIIB, IV, V, VI and VII] recognized by their lattice pattern of linear opacities. Genetic studies on inherited diseases affecting the cornea have provided insight into some of these disorders at a basic molecular level and it has become recognized that distinct clinicopathologic phenotypes can result from specific mutations in a particular gene, as well as some different mutations in the same gene. A molecular genetic understanding of inherited corneal diseases is leading to a better appreciation of the

  14. Indocyanine green staining for the triple corneal procedure.

    Science.gov (United States)

    Kobayashi, Akira; Segawa, Yoji; Nishimura, Akira; Shirao, Yutaka; Sugiyama, Kazuhisa

    2004-01-01

    In the triple corneal procedure, successful completion of capsulorhexis is of the utmost importance. Another use of indocyanine green dye for better visualization of the anterior lens capsule of mature cataract during the triple corneal procedure is described. Four consecutive patients (mean age, 69.5 years) with both mature cataracts and corneal opacity underwent the triple corneal procedure. After trephination of the recipient cornea, the anterior capsule of the lens was stained with indocyanine green. A continuous curvilinear capsulorhexis (CCC) was performed, after which conventional triple corneal procedures were followed. In all four cases, this technique markedly improved visualization of the lens capsule and resulted in successful and easy manipulation of the CCC and subsequent removal of residual lens cortex. Staining of the anterior capsule of mature cataract in the triple corneal procedure clearly defines the border of the capsule, thus allowing easy and complete execution of CCC.

  15. Corneal Laceration

    Medline Plus

    Full Text Available ... from Laundry Packets On the Rise Jun 30, 2017 People with Advanced Keratoconus May Have A Future Alternative to Full Corneal Transplantation Nov 29, 2016 Combating Eye Injuries from Air Guns Aug 30, ...

  16. Corneal transplant

    Science.gov (United States)

    ... lenses to achieve the best vision. Laser vision correction may be an option if you have nearsightedness, ... Editorial team. Related MedlinePlus Health Topics Corneal Disorders Refractive Errors Browse the Encyclopedia A.D.A.M., Inc. ...

  17. Corneal Laceration

    Medline Plus

    Full Text Available ... Pediatric Ophthalmology Education Center Oculofacial Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide ... What Is Corneal Laceration? Leer en Español: ¿Qué ...

  18. Corneal Laceration

    Medline Plus

    Full Text Available ... itself. A corneal laceration is a very serious injury and requires immediate medical attention to avoid severe ... Dangerous for Your Eyes Sep 20, 2017 Eye Injuries from Laundry Packets On the Rise Jun 30, ...

  19. Corneal Laceration

    Medline Plus

    Full Text Available ... itself. A corneal laceration is a very serious injury and requires immediate medical attention to avoid severe ... 27, 2015 Dark Spot in Vision After Blunt Trauma Dec 21, 2014 Pain a Year After Eyelid ...

  20. Corneal Laceration

    Medline Plus

    Full Text Available ... itself. A corneal laceration is a very serious injury and requires immediate medical attention to avoid severe ... and preserving your vision. Privacy Policy Related Eye Injuries from Laundry Packets On the Rise Jun 30, ...

  1. Corneal Laceration

    Medline Plus

    Full Text Available ... 2017 People with Advanced Keratoconus May Have A Future Alternative to Full Corneal Transplantation Nov 29, 2016 Combating Eye Injuries from Air Guns Aug 30, ... Public & Patients: Contact Us About ...

  2. Corneal Laceration

    Medline Plus

    Full Text Available ... by something sharp flying into the eye. It can also be caused by something striking the eye ... If the corneal laceration is deep enough it can cause a full thickness laceration. This is when ...

  3. Corneal Laceration

    Medline Plus

    Full Text Available ... Pediatric Ophthalmology Education Center Oculofacial Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide ... What Is Corneal Laceration? Written By: Daniel Porter ...

  4. Corneal Laceration

    Medline Plus

    Full Text Available ... By: Devin A Harrison MD Sep. 01, 2017 The cornea is the clear front window of the eye . A corneal laceration is a cut on the cornea. It is usually caused by something sharp ...

  5. Corneal Laceration

    Medline Plus

    Full Text Available ... itself. A corneal laceration is a very serious injury and requires immediate medical attention to avoid severe ... 27, 2015 Dark Spot in Vision After Blunt Trauma Dec 21, 2014 Pain a Year After Eyelid ...

  6. First Identification of a Triple Corneal Dystrophy Association: Keratoconus, Epithelial Basement Membrane Corneal Dystrophy and Fuchs' Endothelial Corneal Dystrophy

    Directory of Open Access Journals (Sweden)

    Cosimo Mazzotta

    2014-09-01

    Full Text Available Purpose: To report the observation of a triple corneal dystrophy association consisting of keratoconus (KC, epithelial basement membrane corneal dystrophy (EBMCD and Fuchs' endothelial corneal dystrophy (FECD. Methods: A 55-year-old male patient was referred to our cornea service for blurred vision and recurrent foreign body sensation. He reported bilateral recurrent corneal erosions with diurnal visual fluctuations. He underwent corneal biomicroscopy, Scheimpflug tomography, in vivo HRT confocal laser scanning microscopy and genetic testing for TGFBI and ZEB1 mutations using direct DNA sequencing. Results: Biomicroscopic examination revealed the presence of subepithelial central and paracentral corneal opacities. The endothelium showed a bilateral flecked appearance, and the posterior corneal curvature suggested a possible concomitant ectatic disorder. Corneal tomography confirmed the presence of a stage II KC in both eyes. In vivo confocal laser scanning microscopy revealed a concomitant bilateral EBMCD with hyperreflective deposits in basal epithelial cells, subbasal Bowman's layer microfolds and ridges with truncated subbasal nerves as pseudodendritic elements. Stromal analysis revealed honeycomb edematous areas, and the endothelium showed a strawberry surface configuration typical of FECD. The genetic analysis resulted negative for TGFBI mutations and positive for a heterozygous mutation in exon 7 of the gene ZEB1. Conclusion: This is the first case reported in the literature in which KC, EBMCD and FECD are present in the same patient and associated with ZEB1 gene mutation. The triple association was previously established by means of morphological analysis of the cornea using corneal Scheimpflug tomography and in vivo HRT II confocal laser scanning microscopy.

  7. A comparison between keratoconus and normal population based corneal endothelium

    Directory of Open Access Journals (Sweden)

    Mohamad Aghazade Amiri

    2015-07-01

    Conclusion: Keratoconus does not have any considerable effect on cell density, polymegethism and pleomorphism, in mild and moderate stages and corneal opacity risk caused by intraocular surgeries (such as: Cataract or Glaucoma surgeries and some diseases (such as diabetes and uveitis is similar in keratoconic and normal eyes.

  8. Corneal Transplantation

    DEFF Research Database (Denmark)

    Hjortdal, Jesper Østergaard

    Corneal transplantation has been performed for more than 100 years. Until 15 years ago the state-of-the art type of transplantation was penetrating keratoplasty, but since the start of this millennium, newly designed surgical techniques have developed considerably. Today, the vast majority of ker...

  9. Corneal Laceration

    Medline Plus

    Full Text Available ... Tips & Prevention News Ask an Ophthalmologist Patient Stories Español Eye Health / Eye Health A-Z Corneal Laceration ... After Eyelid Scratch Jul 28, 2014 Leer en Español: ¿Qué Es una Laceración de la Córnea? Find ...

  10. Corneal topography

    DEFF Research Database (Denmark)

    Andersen, J.; Koch-Jensen, P.; Østerby, Ole

    1993-01-01

    The central corneal zone is depicted on keratoscope photographs using a small target aperture and a large object distance. Information on the peripheral area is included by employing a hemispherical target with a dense circular and radial pattern. On a 16 mm (R = 8 mm) reference steel sphere...

  11. Corneal chromoblastomycosis.

    Science.gov (United States)

    Barton, K; Miller, D; Pflugfelder, S C

    1997-03-01

    We sought to illustrate the difficulty in managing uncommon, pigmented mold-related corneal ulceration and to highlight the role of itraconazole in treating these patients. We describe the management and clinical course of a patient with a recurring corneal infection caused by Fonsecaea pedrosoi and discuss this experience in the light of existing literature on management of cutaneous chromoblastomycosis. A corneal ulcer caused by this organism healed initially on treatment with topical and systemic antifungal medication, but infection recurred in the deep stroma 4 months after cessation of therapy. After failure to respond to a further period of medical therapy, a small therapeutic penetrating keratoplasty was performed. Culture of a fibrinous membrane from the anterior iris surface demonstrated intraocular fungal infection, and postoperatively, an episode of marked fibrinous uveitis developed, suggesting the presence of viable intraocular fungal elements. A large penetrating keratoplasty was therefore performed with excision of involved iris in combination with extracapsular cataract extraction. F. pedrosoi was again cultured from the fibrinous membrane adherent to the iris and from the anterior lens capsule. Postoperatively the patient received a 5-month course of systemic itraconazole, and no further recurrences have been encountered after a further 2 months. F. pedrosoi is the organism most commonly isolated from the chronic cutaneous mycosis, chromoblastomycosis, and is relatively resistant to medical therapy. As has been reported for cutaneous disease, surgery in combination with systemic itraconazole may provide the best chance of cure in corneal chromoblastomycosis.

  12. Enhancing OPAC Records for Discovery

    Directory of Open Access Journals (Sweden)

    Patrick Griffis

    2009-09-01

    Full Text Available This article proposes adding keywords and descriptors to the catalog records of electronic databases and media items to enhance their discovery. The authors contend that subject liaisons can add value to OPAC records and enhance discovery of electronic databases and media items by providing searchable keywords and resource descriptions. The authors provide an examination of OPAC records at their own library, which illustrates the disparity of useful keywords and descriptions within the notes field for media item records versus electronic database records. The authors outline methods for identifying useful keywords for indexing OPAC records of electronic databases. Also included is an analysis of the advantages of using Encore’s Community Tag and Community Review features to allow subject liaisons to work directly in the catalog instead of collaborating with cataloging staff

  13. Feline corneal disease.

    Science.gov (United States)

    Moore, Phillip Anthony

    2005-05-01

    The cornea is naturally transparent. Anything that interferes with the cornea's stromal architecture, contributes to blood vessel migration, increases corneal pigmentation, or predisposes to corneal edema, disrupts the corneas transparency and indicates corneal disease. The color, location, and shape and pattern of a corneal lesion can help in determining the underlying cause for the disease. Corneal disease is typically divided into congenital or acquired disorders. Congenital disorders, such as corneal dermoids are rare in cats, whereas acquired corneal disease associated with nonulcerative or ulcerative keratitis is common. Primary ocular disease, such as tear film instability, adenexal disease (medial canthal entropion, lagophthalmus, eyelid agenesis), and herpes keratitis are associated with the majority of acquired corneal disease in cats. Proliferative/eosinophilic keratitis, acute bullous keratopathy, and Florida keratopathy are common feline nonulcerative disorders. Nonprogressive ulcerative disease in cats, such as chronic corneal epithelial defects and corneal sequestration are more common than progressive corneal ulcerations.

  14. Equine corneal stromal abscesses

    DEFF Research Database (Denmark)

    Henriksen, M. D. L.; Andersen, P. H.; Plummer, C. E.

    2013-01-01

    The last 30 years have seen many changes in the understanding of the pathogenesis and treatment of equine corneal stromal abscesses (SAs). Stromal abscesses were previously considered an eye problem related to corneal bacterial infection, equine recurrent uveitis, corneal microtrauma and corneal...

  15. Crystalline Subtype of Pre-Descemetic Corneal Dystrophy

    Directory of Open Access Journals (Sweden)

    Rosa Dolz-Marco

    2014-01-01

    Full Text Available Purpose: To report corneal findings in a familial case of the crystalline subtype of pre- Descemetic corneal dystrophy. Case Report: A 19-year-old girl and her 44-year-old mother were found to have asymptomatic, bilateral, punctiform and multi-colored crystalline opacities across the whole posterior layer of the corneas. Endothelial specular microscopy revealed the presence of white round flecks located at different levels anterior to the endothelium. No systemic abnormalities or medications could be related to account for these findings. Conclusion: To the best of our knowledge, this is the third familial report of this rare corneal disorder. Differential diagnosis may include Schnyder corneal dystrophy, cystinosis, Bietti΄s dystrophy and monoclonal gammopathy.

  16. Iron opacity experiments for the solar interior

    Science.gov (United States)

    Nagayama, T.; Bailey, J. E.; Loisel, G.; Rochau, G. A.; Hansen, S. B.; Blancard, C.; Cosse, Ph.; Faussurier, G.; Gilleron, F.; Pain, J.-C.; Pradhan, A. K.; Orban, C.; Pinsonneault, M.; Nahar, S. N.; Iglesias, C. A.; Wilson, B.; Colgan, J.; Fontes, C.; Kilcrease, D.; Sherrill, M.; Macfarlane, J. J.; Golovkin, I.; Mancini, R. C.

    2014-10-01

    Iron opacity experiments near solar interior conditions are performed at SNL Z-machine to better constrain solar models. The SNL opacity science platform satisfies the many challenging requirements for opacity measurements and successfully determines iron opacities at multiple conditions. We found that the agreement between the modeled opacity and the measured opacity deteriorates as Te and ne are raised to approach solar interior conditions. While the inaccuracy of the modeled opacity partially resolves the solar abundance problem, the announcement of such discrepancies has a high impact on the astrophysics, atomic physics, and high energy density physics, and thus more scrutiny on the potential experimental flaws is critical. We report the synthetic investigation for potential sources of systematic uncertainties in the experiments. Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy under Contract DE-AC04-94AL85000.

  17. A new, band-shaped and whorled microcystic dystrophy of the corneal epithelium.

    Science.gov (United States)

    Lisch, W; Steuhl, K P; Lisch, C; Weidle, E G; Emmig, C T; Cohen, K L; Perry, H D

    1992-07-15

    Five family members and three unrelated patients (four women, four men, 23 to 71 years old) had a dystrophy of the corneal epithelium. Direct slit-lamp examination showed bilateral or unilateral, gray, band-shaped, and feathery opacities that sometimes appeared in whorled patterns. Retroillumination showed intraepithelial, densely crowded, clear microcysts. Light and electron microscopy disclosed diffuse vacuolization of the cytoplasm of epithelial cells in the affected area. Visual acuity was so reduced in three patients that abrasion of the corneal epithelium was performed. The corneal abnormalities recurred within months, with the same reduction in visual acuity as before. The corneal opacities were progressive in two patients but diminished noticeably in another after he began using a hard contact lens. We found no other ophthalmic irregularities or associated systemic abnormalities and no indication of drug-induced keratopathy.

  18. Induction of corneal collagen cross-linking in experimental corneal alkali burns in rabbits

    Directory of Open Access Journals (Sweden)

    Marcello Colombo-Barboza

    2014-10-01

    Full Text Available Objective: To evaluate the effect of riboflavin-ultraviolet-A-induced cross-linking (CXL following corneal alkali burns in rabbits. Methods: The right corneas and limbi of ten rabbits were burned using a 1N solution of NaOH and the animals were then divided into two groups: a control group submitted to clinical treatment alone and an experimental group that was treated 1 h after injury with CXL, followed by the same clinical treatment as administered to the controls. Clinical parameters were evaluated post-injury at 1, 7, 15, and 30 days by two independent observers. Following this evaluation, the corneas were excised and examined histologically. Results: There were no statistically significant differences in clinical parameters, such as hyperemia, corneal edema, ciliary injection, limbal ischemia, secretion, corneal neovascularization, symblepharon, or blepharospasm, at any of the time-points evaluated. However, the size of the epithelial defect was significantly smaller in the CXL group (p<0.05 (day 15: p=0.008 and day 30: p=0.008 and the extent of the corneal injury (opacity lesion was also smaller (day 30: p=0.021. Histopathology showed the presence of collagen bridges linking the collagen fibers in only the CXL group. Conclusions: These results suggest that the use of CXL may improve the prognosis of acute corneal alkali burns.

  19. Line Broadening and the Solar Opacity Problem

    Science.gov (United States)

    Krief, M.; Feigel, A.; Gazit, D.

    2016-06-01

    The calculation of line widths constitutes theoretical and computational challenges in the calculation of opacities of hot, dense plasmas. Opacity models use line broadening approximations that are untested at stellar interior conditions. Moreover, calculations of atomic spectra of the Sun indicate a large discrepancy in the K-shell line widths between several atomic codes and the Opacity-Project (OP). In this work, the atomic code STAR is used to study the sensitivity of solar opacities to line broadening. Variations in the solar opacity profile due to an increase of the Stark widths resulting from discrepancies with OP, are compared, in light of the solar opacity problem, with the required opacity variations of the present day Sun, as imposed by helioseismic and neutrino observations. The resulting variation profile is much larger than the discrepancy between different atomic codes, agrees qualitatively with the missing opacity profile, recovers about half of the missing opacity nearby the convection boundary, and has a little effect in the internal regions. Since it is hard to estimate quantitatively the uncertainty in the Stark widths, we show that an increase of all line widths by a factor of about ˜100 recovers quantitatively the missing opacity. These results emphasize the possibility that photoexcitation processes are not modeled properly, and more specifically, highlight the need for a better theoretical characterization of the line broadening phenomena at stellar interior conditions, and of the uncertainty due to the way it is implemented by atomic codes.

  20. Corneal ulcers in horses.

    Science.gov (United States)

    Williams, Lynn B; Pinard, Chantale L

    2013-01-01

    Corneal ulceration is commonly diagnosed by equine veterinarians. A complete ophthalmic examination as well as fluorescein staining, corneal cytology, and corneal bacterial (aerobic) and fungal culture and sensitivity testing are necessary for all infected corneal ulcers. Appropriate topical antibiotics, topical atropine, and systemic NSAIDs are indicated for all corneal ulcers. If keratomalacia (melting) is observed, anticollagenase/antiprotease therapy, such as autologous serum, is indicated. If fungal infection is suspected, antifungal therapy is a necessity. Subpalpebral lavage systems allow convenient, frequent, and potentially long-term therapy. Referral corneal surgeries provide additional therapeutic options when the globe's integrity is threatened or when improvement has not been detected after appropriate therapy.

  1. Corneal transplant - discharge

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/patientinstructions/000243.htm Corneal transplant - discharge To use the sharing features on this page, please enable JavaScript. You had a corneal transplant. Most of the tissue of your cornea (the ...

  2. Analytical opacity formulas for low Z plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Rubiano, J; Rodriguez, R; Gil, J M; Florido, R; Martel, P; Mendoza, M A; Suarez, D [Departamento de FIasica, Universidad de Las Palmas de GC, 35017 Las Palmas de GC (Spain); Minguez, E [Instituto de Fusion Nuclear DENIM. Universidad Politecnica de Madrid, 28019 Madrid (Spain)], E-mail: jgarcia@dfis.ulpgc.es

    2008-05-01

    The accurate computation of radiative opacities is basic in the ICF target physics analysis, in which the radiation is an important feature to determine in detail. For this reason, accurate analytical formulas for giving mean opacities versus temperature and density of the plasma seem to be a useful tool. In this work we analyse some analytical expressions found in the literature for the opacity low Z plasmas in a wide range of temperature and densities. The validity of these formulas for computing the opacity under NLTE conditions is investigated using the new code ABAKO.

  3. The corneal fibrosis response to epithelial-stromal injury.

    Science.gov (United States)

    Torricelli, Andre A M; Santhanam, Abirami; Wu, Jiahui; Singh, Vivek; Wilson, Steven E

    2016-01-01

    The corneal wound healing response, including the development of stromal opacity in some eyes, is a process that often leads to scarring that occurs after injury, surgery or infection to the cornea. Immediately after epithelial and stromal injury, a complex sequence of processes contributes to wound repair and regeneration of normal corneal structure and function. In some corneas, however, often depending on the type and extent of injury, the response may also lead to the development of mature vimentin+ α-smooth muscle actin+ desmin+ myofibroblasts. Myofibroblasts are specialized fibroblastic cells generated in the cornea from keratocyte-derived or bone marrow-derived precursor cells. The disorganized extracellular matrix components secreted by myofibroblasts, in addition to decreased expression of corneal crystallins in these cells, are central biological processes that result in corneal stromal fibrosis associated with opacity or "haze". Several factors are associated with myofibroblast generation and haze development after PRK surgery in rabbits, a reproducible model of scarring, including the amount of tissue ablated, which may relate to the extent of keratocyte apoptosis in the early response to injury, irregularity of stromal surface after surgery, and changes in corneal stromal proteoglycans, but normal regeneration of the epithelial basement membrane (EBM) appears to be a critical factor determining whether a cornea heals with relative transparency or vision-limiting stromal opacity. Structural and functional abnormalities of the regenerated EBM facilitate prolonged entry of epithelium-derived growth factors such as transforming growth factor β (TGF-β) and platelet-derived growth factor (PDGF) into the stroma that both drive development of mature myofibroblasts from precursor cells and lead to persistence of the cells in the anterior stroma. A major discovery that has contributed to our understanding of haze development is that keratocytes and corneal

  4. The GUI OPAC: Approach with Caution.

    Science.gov (United States)

    Hildreth, Charles R.

    1995-01-01

    Discusses the graphical user interface (GUI) online public access catalog (OPAC), a user interface that uses images to represent options. Topics include user interface design for information retrieval; designing effective bibliographic displays, including subject headings; two design principles; and what GUIs can bring to OPACs. (LRW)

  5. Corneal organ cultures in tyrosinemia release chemotactic factors.

    Science.gov (United States)

    Lohr, K M; Hyndiuk, R A; Hatchell, D L; Kurth, C E

    1985-05-01

    Corneal inflammation with subsequent scarring and blindness occurs in the inherited human metabolic disease tyrosinemia type II, yet putative inflammatory mediators in this disorder and in the avascular cornea in general are poorly defined. In a Tyr-fed rat model of tyrosinemia type II, intracellular crystals, presumably Tyr, are hypothesized to be responsible for the increased lysosomal activity observed in corneal epithelial lesions. Because polymorphonuclear leukocytes (PMNs) are seen only at the site of these lesions, we used this model to study humoral mediators released from Tyr-fed rat corneal organ cultures. Only Tyr-fed rats developed stromal edema and linear granular opacities in gray edematous corneal epithelium, compatible with a noninfectious keratitis. Electron micrographs confirmed epithelial edema and showed focal epithelial necrosis with PMN invasion of the stroma. Only Tyr-fed rat corneal culture supernatants contained chemotactic activity that was heat labile and moderately trypsin sensitive. Four peaks with varying amounts of chemotactic activity were found on Sephadex G-75 chromatography. Although the identity of these peaks of activity has not yet been established, we suggest that they may be responsible for the PMN infiltration observed in this model of corneal inflammation.

  6. Sands of Sahara after LASIK in Avellino Corneal Dystrophy

    Directory of Open Access Journals (Sweden)

    Flavio Mantelli

    2012-01-01

    Full Text Available We report the case of a patient diagnosed with Avellino corneal dystrophy (ACD who developed diffuse interstitial keratitis following excimer laser insitu keratomileusis (LASIK. ACD is an autosomal dominant corneal dystrophy characterized by multiple asymmetric stromal opacities that impair vision. Accepted treatments for this condition include corneal transplantation and phototherapeutic keratectomy (PTK. Our patient underwent LASIK at another institution to correct myopia. LASIK and photorefractive keratectomy (PRK are usually contraindicated in ACD for the high risk of disease recurrence and postoperative complications. The patient came to our attention lamenting blurry vision, decreased visual acuity, and photophobia. Ophthalmologic examination revealed bilateral interstitial keratitis, also known as “sands of Sahara”, a seldom-seen complication of LASIK characterized by fine and diffuse granular infiltrates at the surgical flap interface.The risk of developing interstitial keratitis, as in the case presented here, represents another valid reason for avoiding LASIK in patients with ACD.

  7. TSG-6 protects corneal endothelium from transcorneal cryoinjury in rabbits.

    Science.gov (United States)

    Kim, Jeong-Ah; Ko, Jung Hwa; Ko, Ah Young; Lee, Hyun Ju; Kim, Mee Kum; Wee, Won Ryang; Lee, Ryang Hwa; Fulcher, Samuel F; Oh, Joo Youn

    2014-07-17

    To investigate the effect of an anti-inflammatory protein, TNF-α stimulated gene/protein (TSG)-6 and an antiapoptotic protein, stanniocalcin (STC)-1 on corneal endothelium in rabbits with transcorneal cryoinjury. Transcorneal freezing (-80°C) was applied to rabbit corneas for 30 seconds. Immediately post injury, either TSG-6 (10 μg/100 μL), STC-1 (10 μg/100 μL), or the same volume of balanced salt solution (BSS) was injected into the anterior chamber. Each eye was examined for corneal opacity, corneal thickness, endothelial cell density, and endothelial hexagonality every 2 to 6 hours for 48 hours post injury. The concentrations of myeloperoxidase (MPO) and IL-1β were measured in the aqueous humor every 6 hours. At 48 hours post injury, each cornea was assayed for TNF-α, IL-1β, IL-6, and MPO, and histologically evaluated with alizarin red-trypan blue staining, hematoxylin-eosin staining, and immunostaining for neutrophils. Tumor necrosis factor-α stimulated gene/protein-6 significantly decreased the development of corneal opacity and edema after cryoinjury compared with STC-1 or BSS. The corneal endothelial cell density and hexagonality were markedly preserved by TSG-6. The mRNA levels of TNF-α, IL-1β, and IL-6 in the cornea and the protein levels of MPO and IL-1β in the aqueous humor and cornea were significantly lower in TSG-6-treated eyes than BSS-treated controls. Similarly, the expression of fibroblast growth factor-2 was reduced by TSG-6 treatment. Histologic evaluation demonstrated that neutrophil infiltration of the cornea was decreased in TSG-6-treated eyes. Tumor necrosis factor-α stimulated gene/protein-6 protected corneal endothelial cells from transcorneal cryoinjury through suppression of inflammation. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  8. Tissue engineering of corneal stroma with rabbit fibroblast precursors and gelatin hydrogels.

    Science.gov (United States)

    Mimura, Tatsuya; Amano, Shiro; Yokoo, Seiichi; Uchida, Saiko; Yamagami, Satoru; Usui, Tomohiko; Kimura, Yu; Tabata, Yasuhiko

    2008-01-01

    To isolate fibroblast precursors from rabbit corneal stroma using a sphere-forming assay, to engineer corneal stroma with the precursors and gelatin, and to establish the therapeutic application of precursors in a rabbit corneal stroma. In the in vitro study, a sphere-forming assay was performed to produce precursors from rabbit corneal stroma. Corneal stroma was engineered by cultivating precursors in porous gelatin for one week. In the in vivo study, the engineered corneal stromal sheet with precursors (precursor/gelatin group) or with fibroblasts (fibroblast /gelatin group) or without cells (gelatin group) was transplanted to a pocket of rabbit corneal stroma. Gene expression and extracellular matrix production were examined immunohistochemically in each group one week and four weeks after surgery. In the in vitro study, cells in the spheres were BrdU-positive, and their progeny were keratocan-positive. The study also showed that the corneas transplanted with a porous gelatin sheet did not show any opacity four weeks after transplantation in any group. In the gelatin sheet of the precursor/gelatin group, a more intense expression of type I collagen was observed relative to the other two groups four weeks after the surgery. Our findings demonstrate that the transplantation of fibroblast precursors combined with gelatin hydrogel into the corneal stroma is a possible treatment strategy for corneal stromal regeneration.

  9. Line broadening and the solar opacity problem

    CERN Document Server

    Krief, M; Gazit, D

    2016-01-01

    The calculation of line widths constitutes a theoretical as well as a computational challenge in the calculation of opacities of hot dense plasmas. Opacity models use line broadening approximations that are untested at stellar interior conditions. Moreover, calculations of atomic spectra nearby the convection zone boundary (CZB) of the sun, indicate a large discrepancy in the K-shell line widths between several atomic codes and the Opacity-Project. In this work, the atomic code STAR is used to study the sensitivity of solar opacities to line-broadening. Atomic spectra of several elements are analyzed and compared within the solar interior. Variations in the solar opacity profile due to changes in the Stark widths are shown to be significant and to result mainly due to K-shell lines. In light of the solar opacity problem, the results are compared with the required opacity variations of the present day sun, as imposed by helioseismic and neutrino observations. It is shown that an increase of the line widths res...

  10. Restricted fish feeding reduces cod otolith opacity

    DEFF Research Database (Denmark)

    Høie, H.; Folkvord, A.; Mosegaard, Henrik

    2008-01-01

    The purpose of this work was to examine the effect of reduced feeding and constant temperature on cod otolith opacity. Three groups of juvenile cod were given restricted food rations at different times for 4 months, resulting in depressed somatic growth. Otolith opacity was measured on pictures...... in otolith opacity were found between individual fish both within groups and between groups. In two of the three groups significantly more translucent otolith material was deposited in response to reduced feeding. Our results show that variations in feeding and hence fish growth resulted in variation...

  11. Corneal mucus plaques.

    Science.gov (United States)

    Fraunfelder, F T; Wright, P; Tripathi, R C

    1977-02-01

    Corneal mucus plaques adhered to the anterior corneal surface in 17 of 67 advanced cases of keratoconjunctivitis sicca. The plaques were translucent to opaque and varied in size and shape, from multiple isolated islands to bizarre patterns involving more than half the corneal surface. Ultrastructurally, they consisted of mucus mixed with desquamated degenerating epithelial cells and proteinaceous and lipoidal material. The condition may be symptomatic but can be controlled and prevented in most cases by topical ocular application of 10% acetylcysteine.

  12. Summary of Fe opacity measurement platform

    Energy Technology Data Exchange (ETDEWEB)

    Nagayama, Taisuke

    2016-05-01

    This powerpoint presentation goes over the Fe opacity measurement platform, including how the experiment works, what can be gathered from the measurements, what can be gathered from the simulations, and the limitations of the experiment.

  13. The neutrino opacity of neutron rich matter

    Energy Technology Data Exchange (ETDEWEB)

    Alcain, P.N., E-mail: pabloalcain@gmail.com [Departamento de Física, FCEyN, UBA and IFIBA, Conicet, Pabellón 1, Ciudad Universitaria, 1428 Buenos Aires (Argentina); IFIBA-CONICET (Argentina); Dorso, C.O. [Departamento de Física, FCEyN, UBA and IFIBA, Conicet, Pabellón 1, Ciudad Universitaria, 1428 Buenos Aires (Argentina); IFIBA-CONICET (Argentina)

    2017-05-15

    The study of neutron rich matter, present in neutron star, proto-neutron stars and core-collapse supernovae, can lead to further understanding of the behavior of nuclear matter in highly asymmetric nuclei. Heterogeneous structures are expected to exist in these systems, often referred to as nuclear pasta. We have carried out a systematic study of neutrino opacity for different thermodynamic conditions in order to assess the impact that the structure has on it. We studied the dynamics of the neutrino opacity of the heterogeneous matter at different thermodynamic conditions with semiclassical molecular dynamics model already used to study nuclear multifragmentation. For different densities, proton fractions and temperature, we calculate the very long range opacity and the cluster distribution. The neutrino opacity is of crucial importance for the evolution of the core-collapse supernovae and the neutrino scattering.

  14. New Generation of Los Alamos Opacity Tables

    Science.gov (United States)

    Colgan, James; Kilcrease, D. P.; Magee, N. H.; Sherrill, M. E.; Abdallah, J.; Hakel, P.; Fontes, C. J.; Guzik, J. A.; Mussack, K. A.

    2016-05-01

    We present a new generation of Los Alamos OPLIB opacity tables that have been computed using the ATOMIC code. Our tables have been calculated for all 30 elements from hydrogen through zinc and are publicly available through our website. In this poster we discuss the details of the calculations that underpin the new opacity tables. We also show several recent applications of the use of our opacity tables to solar modeling and other astrophysical applications. In particular, we demonstrate that use of the new opacities improves the agreement between solar models and helioseismology, but does not fully resolve the long-standing `solar abundance' problem. The Los Alamos National Laboratory is operated by Los Alamos National Security, LLC for the National Nuclear Security Administration of the U.S. Department of Energy under Contract No. DE-AC5206NA25396.

  15. Antifibrotic effect by activation of peroxisome proliferator-activated receptor-gamma in corneal fibroblasts.

    Science.gov (United States)

    Pan, Hongwei; Chen, Jiansu; Xu, Jintang; Chen, Miaojiao; Ma, Rong

    2009-11-10

    The transformation of quiescent keratocytes to active phenotypes and the ensuing fibrotic response play important roles in corneal scar formation. This study aims to observe the antifibrotic effect of peroxisome proliferator-activated receptor-gamma (PPARgamma) agonist on corneal fibroblasts cultured in vitro, and to explore the potential application of peroxisome proliferator-activated receptor agonist to the prevention of corneal opacity following wound repair. Rabbit corneal keratocytes were cultured in a medium containing 10% serum to induce their transformation to fibroblasts and myofibroblasts, which are similar to those that repair corneas. After incubation with the PPARgamma agonist pioglitazone at different concentrations, the effect of pioglitazone on the migration, contractility, and viability of corneal fibroblasts was examined. The secretion of matrix metalloproteinase-2 and matrix metalloproteinase-9 was determined by gelatin zymography, and the synthesis of collagen I and fibronectin was investigated by western blotting. Treatment with pioglitazone at concentrations ranging from 1 to 10 mum significantly decreased corneal fibroblast migration, as determined by scrape-wound assay, inhibited corneal fibroblast-induced collagen lattice contraction, and reduced MMP-2 and MMP-9 secretion into the supernatant of cell cultures in a dose-dependent manner. The expression of fibronectin was significantly decreased, while the expression of collagen I was only decreased when treated with 10 mum pioglitazone. Cell viability was not evidently changed compared to the control. This in vitro study demonstrated the anti-fibrotic effect of pioglitazone, suggesting that activation of PPARgamma may be a new approach for the treatment of corneal opacity and scar formation in the corneal wound healing process.

  16. Opacity Issues in Games with Imperfect Information

    Directory of Open Access Journals (Sweden)

    Bastien Maubert

    2011-06-01

    Full Text Available We study in depth the class of games with opacity condition, which are two-player games with imperfect information in which one of the players only has imperfect information, and where the winning condition relies on the information he has along the play. Those games are relevant for security aspects of computing systems: a play is opaque whenever the player who has imperfect information never "knows" for sure that the current position is one of the distinguished "secret" positions. We study the problems of deciding the existence of a winning strategy for each player, and we call them the opacity-violate problem and the opacity-guarantee problem. Focusing on the player with perfect information is new in the field of games with imperfect-information because when considering classical winning conditions it amounts to solving the underlying perfect-information game. We establish the EXPTIME-completeness of both above-mentioned problems, showing that our winning condition brings a gap of complexity for the player with perfect information, and we exhibit the relevant opacity-verify problem, which noticeably generalizes approaches considered in the literature for opacity analysis in discrete-event systems. In the case of blindfold games, this problem relates to the two initial ones, yielding the determinacy of blindfold games with opacity condition and the PSPACE-completeness of the three problems.

  17. Observational Constraints on Submillimeter Dust Opacity

    CERN Document Server

    Shirley, Yancy L; Pontoppidan, Klaus M; Wilner, David J; Stutz, Amelia M; Bieging, John H; Evans, Neal J

    2010-01-01

    Infrared extinction maps and submillimeter dust continuum maps are powerful probes of the density structure in the envelope of star-forming cores. We make a direct comparison between infrared and submillimeter dust continuum observations of the low-mass Class 0 core, B335, to constrain the ratio of submillimeter to infrared opacity (\\kaprat) and the submillimeter opacity power-law index ($\\kappa \\propto \\lambda^{-\\beta}$). Using the average value of theoretical dust opacity models at 2.2 \\micron, we constrain the dust opacity at 850 and 450 \\micron . Using new dust continuum models based upon the broken power-law density structure derived from interferometric observations of B335 and the infall model derived from molecular line observations of B335, we find that the opacity ratios are $\\frac{\\kappa_{850}}{\\kappa_{2.2}} = (3.21 - 4.80)^{+0.44}_{-0.30} \\times 10^{-4}$ and $\\frac{\\kappa_{450}}{\\kappa_{2.2}} = (12.8 - 24.8)^{+2.4}_{-1.3} \\times 10^{-4}$ with a submillimeter opacity power-law index of $\\beta_{smm}...

  18. Radiation Transport for Explosive Outflows: Opacity Regrouping

    CERN Document Server

    Wollaeger, Ryan T

    2014-01-01

    Implicit Monte Carlo (IMC) and Discrete Diffusion Monte Carlo (DDMC) are methods used to stochastically solve the radiative transport and diffusion equations, respectively. These methods combine into a hybrid transport-diffusion method we refer to as IMC-DDMC. We explore a multigroup IMC-DDMC scheme that, in DDMC, combines frequency groups with sufficient optical thickness. We term this procedure "opacity regrouping". Opacity regrouping has previously been applied to IMC-DDMC calculations for problems in which the dependence of the opacity on frequency is monotonic. We generalize opacity regrouping to non-contiguous groups and implement this in \\supernu, a code designed to do radiation transport in high-velocity outflows with non-monotonic opacities. We find that regrouping of non-contiguous opacity groups generally improves the speed of IMC-DDMC radiation transport. We present an asymptotic analysis that informs the nature of the Doppler shift in DDMC groups and summarize the derivation of the Gentile-Fleck ...

  19. Analytical opacity formulas for ICF elements

    Energy Technology Data Exchange (ETDEWEB)

    Minguez, E. E-mail: minguez@denim.upm.es; Martel, P.; Gil, J.M.; Rubiano, J.G.; Rodriguez, R

    2002-01-01

    Local Thermodynamic Equilibrium (LTE) opacity codes have been developed by the Instituto de Fusion Nuclear (DENIM) during the last years. JIMENA code (Laser and Particle Beams 6 (1998) 265; Laser and Particle Beams 10 (1992) 651) is an opacity code that solves self-consistently, for each temperature and density, the radial Dirac equation with a local spherically symmetrical potential. Very recently we have developed a new opacity code, called ANALOP, that uses an analytical potential (JQSRT 54 (1995) 621), which can include density and temperature effects for atomic data calculations. Opacities are determined with these two codes for selected elements at different plasma conditions. This work is focused on the determination of Rosseland and Planck mean analytical formulas for several single elements used in ICF targets. A scaling law of these mean opacities is given as a function of the plasma parameters: electron temperature and plasma density. These opacities have been tested with numerical results from other codes and with available experimental results.

  20. RECURRENT CORNEAL EROSION SYNDROME (a review

    Directory of Open Access Journals (Sweden)

    S. V. Trufanov

    2015-01-01

    Full Text Available Recurrent corneal erosion (RCE syndrome is characterized by episodes of recurrent spontaneous epithelial defects. Main clinical symptoms (pain, redness, photophobia, lacrimation occurred at night. Corneal lesions revealed by slit lamp exam vary depending on the presence of corneal epithelium raise, epithelial microcysts or epithelial erosions, stromal infiltrates and opacities. Microtraumas, anterior corneal dystrophies, and herpesvirus give rise to RCE. Other causes or factors which increase the risk of RCE syndrome include meibomian gland dysfunction, keratoconjunctivitis sicca, diabetes, and post-LASIK conditions. Basal membrane abnormalities and instability of epithelial adhesion to stroma play a key role in RCE pathogenesis. Ultrastructural changes in RCE include abnormalities of basal epithelial cells and epithelial basal membrane, absence or deficiency of semi-desmosomes, loss of anchor fibrils. Increase in matrix metalloproteinases and collagenases which contribute to basal membrane destruction results in recurrent erosions and further development of abnormal basal membrane. The goals of RCE therapy are to reduce pain (in acute stage, to stimulate re-epithelization, and to restore «adhesion complex» of basal membrane. In most cases, RCE responds to simple conservative treatment that includes lubricants, healing agents, and eye patches. RCEs that are resistant to simple treatment, require complex approach. Non-invasive methods include long-term contact lens use, instillations of autologous serum (eye drops, injections of botulinum toxin (induces ptosis, antiviral agent use or oral intake of metalloproteinase inhibitors. Cell membrane stabilizers, i.e., antioxidants, should be included into treatment approaches as well. Antioxidant effect of Emoxipine promotes tissue reparation due to the prevention of cell membrane lipid peroxidation as well as due to its anti-hypoxic, angioprotective, and antiplatelet effects. If conservative therapy

  1. A new multiple noncontinuous puncture (pointage technique for corneal tattooing

    Directory of Open Access Journals (Sweden)

    Jin Hyoung Park

    2015-10-01

    Full Text Available AIM:To assess the safety and cosmetic efficacy of a new multiple noncontinuous transepithelial puncture technique for tattooing a decompensated cornea.METHODS:It was anon-comparative clinical case series study.The study examines 33 eyes in 33 patients with total corneal opacity due to corneal decompensation, which developed following intraocular surgery.Corneal tattooing was performed using the multiple noncontinuous transepithelial puncture technique (i.e. pointage. The safety of this new surgical strategy was assessed by occurrence of adverse events for the follow-up period. The cosmetic efficacy was determined by the patient’s cosmetic satisfaction and independent observer’s opinion about patient appearance.RESULTS:Seven women and 26 men were included in the study. The mean age was 46.4±17.5y (range:7-67. In total, 30 of 33 patients (91% reported cosmetic satisfaction within the follow-up period. Only 3 patients (9% required additional tattooing due to cosmetic unsatisfaction. Cosmetic outcomes were analyzed and classified as excellent or good in 13 (39% and 17 (52% patients, respectively. No serious adverse events developed, except delayed epithelial healing in 3 cases.CONCLUSION:The cosmetic outcomes of the multiple noncontinuous transepithelial puncture technique for corneal tattooing were good. The safety of this method is higher than conventional procedures. This new procedure also provides improved cost-effectiveness and safety over current corneal tattooing techniques.

  2. Spontaneous corneal perforation in an eye with Peters' anomaly

    Directory of Open Access Journals (Sweden)

    Kim M

    2013-07-01

    Full Text Available Moosang Kim, Seung-Chan Lee, Seung-Jun Lee Department of Ophthalmology, School of Medicine, Kangwon National University, Chuncheon, South Korea Abstract: A premature female infant underwent her first ophthalmologic examination at the age of 4 weeks. The initial examination of the baby was requested for evaluation of a ‘white spot’ on the surface of her right eye. She had been hospitalized in the neonatal intensive care unit because of systemic abnormalities, such as a right clavicle fracture and microcephaly. Slit-lamp examination of the right eye showed a central corneal opacity, corneal thinning, and an iridocorneal adhesion. The lens and fundus of the right eye could not be observed. We observed no pathologic findings in the left eye. The baby's parents were informed of the high risk for spontaneous corneal perforation without external pressure. At 42 days of age, an ophthalmologic examination of the infant was again requested for evaluation of ‘tears’ from her right eye 3 hours previously. Examination revealed corneal perforation, iris protrusion, and a flat anterior chamber. We performed emergent conjunctival flap surgery. Three months following surgery, the patient's right eye was successfully preserved with no sign of inflammation or leakage. Keywords: conjunctival flap, corneal perforation, Peters' anomaly

  3. Characterization of Corneal Indentation Hysteresis.

    Science.gov (United States)

    Ko, Match W L; Dongming Wei; Leung, Christopher K S

    2015-01-01

    Corneal indentation is adapted for the design and development of a characterization method for corneal hysteresis behavior - Corneal Indentation Hysteresis (CIH). Fourteen porcine eyes were tested using the corneal indentation method. The CIH measured in enucleated porcine eyes showed indentation rate and intraocular pressure (IOP) dependences. The CIH increased with indentation rate at lower IOP ( 25 mmHg). The CIH was linear proportional to the IOP within an individual eye. The CIH was positively correlated with the IOP, corneal in-plane tensile stress and corneal tangent modulus (E). A new method based on corneal indentation for the measurement of Corneal Indentation Hysteresis in vivo is developed. To our knowledge, this is the first study to introduce the corneal indentation hysteresis and correlate the corneal indentation hysteresis and corneal tangent modulus.

  4. Polysaccharide hydrogel combined with mesenchymal stem cells promotes the healing of corneal alkali burn in rats.

    Directory of Open Access Journals (Sweden)

    Yifeng Ke

    Full Text Available Corneal chemical burns are common ophthalmic injuries that may result in permanent visual impairment. Although significant advances have been achieved on the treatment of such cases, the structural and functional restoration of a chemical burn-injured cornea remains challenging. The applications of polysaccharide hydrogel and subconjunctival injection of mesenchymal stem cells (MSCs have been reported to promote the healing of corneal wounds. In this study, polysaccharide was extracted from Hardy Orchid and mesenchymal stem cells (MSCs were derived from Sprague-Dawley rats. Supplementation of the polysaccharide significantly enhanced the migration rate of primarily cultured rat corneal epithelial cells. We examined the therapeutic effects of polysaccharide in conjunction with MSCs application on the healing of corneal alkali burns in rats. Compared with either treatment alone, the combination strategy resulted in significantly better recovery of corneal epithelium and reduction in inflammation, neovascularization and opacity of healed cornea. Polysaccharide and MSCs acted additively to increase the expression of anti-inflammatory cytokine (TGF-β, antiangiogenic cytokine (TSP-1 and decrease those promoting inflammation (TNF-α, chemotaxis (MIP-1α and MCP-1 and angiogenesis (VEGF and MMP-2. This study provided evidence that Hardy Orchid derived polysaccharide and MSCs are safe and effective treatments for corneal alkali burns and that their benefits are additive when used in combination. We concluded that combination therapy with polysaccharide and MSCs is a promising clinical treatment for corneal alkali burns and may be applicable for other types of corneal disorder.

  5. RADIATION TRANSPORT FOR EXPLOSIVE OUTFLOWS: OPACITY REGROUPING

    Energy Technology Data Exchange (ETDEWEB)

    Wollaeger, Ryan T. [Department of Nuclear Engineering and Engineering Physics, University of Wisconsin, Madison 1500 Engineering Drive, 410 ERB, Madison, WI 53706 (United States); Van Rossum, Daniel R., E-mail: wollaeger@wisc.edu, E-mail: daan@flash.uchicago.edu [Flash Center for Computational Science, Department of Astronomy and Astrophysics, University of Chicago, Chicago, IL 60637 (United States)

    2014-10-01

    Implicit Monte Carlo (IMC) and Discrete Diffusion Monte Carlo (DDMC) are methods used to stochastically solve the radiative transport and diffusion equations, respectively. These methods combine into a hybrid transport-diffusion method we refer to as IMC-DDMC. We explore a multigroup IMC-DDMC scheme that in DDMC, combines frequency groups with sufficient optical thickness. We term this procedure ''opacity regrouping''. Opacity regrouping has previously been applied to IMC-DDMC calculations for problems in which the dependence of the opacity on frequency is monotonic. We generalize opacity regrouping to non-contiguous groups and implement this in SuperNu, a code designed to do radiation transport in high-velocity outflows with non-monotonic opacities. We find that regrouping of non-contiguous opacity groups generally improves the speed of IMC-DDMC radiation transport. We present an asymptotic analysis that informs the nature of the Doppler shift in DDMC groups and summarize the derivation of the Gentile-Fleck factor for modified IMC-DDMC. We test SuperNu using numerical experiments including a quasi-manufactured analytic solution, a simple 10 group problem, and the W7 problem for Type Ia supernovae. We find that opacity regrouping is necessary to make our IMC-DDMC implementation feasible for the W7 problem and possibly Type Ia supernova simulations in general. We compare the bolometric light curves and spectra produced by the SuperNu and PHOENIX radiation transport codes for the W7 problem. The overall shape of the bolometric light curves are in good agreement, as are the spectra and their evolution with time. However, for the numerical specifications we considered, we find that the peak luminosity of the light curve calculated using SuperNu is ∼10% less than that calculated using PHOENIX.

  6. The opacity of spiral galaxy disks V. Dust opacity, HI distributions and sub-mm emission

    NARCIS (Netherlands)

    Holwerda, BW; Gonzalez, RA; Allen, RJ; van der Kruit, PC

    2005-01-01

    The opacity of spiral galaxy disks, from counts of distant galaxies, is compared to HI column densities. The opacity measurements are calibrated using the "Synthetic Field Method" from Gonzalez et al. (1998, ApJ, 506, 152), Holwerda et al. (2005a, AJ, 129, 1381). When compared for individual disks,

  7. Current status of corneal xenotransplantation.

    Science.gov (United States)

    Kim, Mee Kum; Hara, Hidetaka

    2015-11-01

    Corneal allo-transplantation is a well-established technique to treat corneal blindness. However, the limited availability of human donors demands the exploration of alternative treatments such as corneal xenotransplantation (e.g., pigs as donors) and bioengineered corneas. Since the first attempt of corneal xenotransplantation using a donor pig cornea in 1844, great advances have been made in the development of genetically-engineered pigs, effective immunosuppressive protocols and the establishment of guidelines for the conduction of clinical trials. We highlight immunological and physio-anatomical barriers of corneal xenotransplantation, recent progress of corneal xenotransplantation in non-human-primates studies, and regulatory guidelines to conduct clinical trials for corneal xenotransplantation.

  8. OPserver: opacities and radiative accelerations on demand

    Science.gov (United States)

    Mendoza, C.; González, J.; Seaton, M. J.; Buerger, P.; Bellorín, A.; Meléndez, M.; Rodríguez, L. S.; Delahaye, F.; Zeippen, C. J.; Palacios, E.; Pradhan, A. K.

    2009-05-01

    We report on developments carried out within the Opacity Project (OP) to upgrade atomic database services to comply with e-infrastructure requirements. We give a detailed description of an interactive, online server for astrophysical opacities, referred to as OPserver, to be used in sophisticated stellar modelling where Rosseland mean opacities and radiative accelerations are computed at every depth point and each evolution cycle. This is crucial, for instance, in chemically peculiar stars and in the exploitation of the new asteroseismological data. OPserver, downloadable with the new OPCD_3.0 release from the Centre de Données Astronomiques de Strasbourg, France, computes mean opacities and radiative data for arbitrary chemical mixtures from the OP monochromatic opacities. It is essentially a client-server network restructuring and optimization of the suite of codes included in the earlier OPCD_2.0 release. The server can be installed locally or, alternatively, accessed remotely from the Ohio Supercomputer Center, Columbus, Ohio, USA. The client is an interactive web page or a subroutine library that can be linked to the user code. The suitability of this scheme in grid computing environments is emphasized, and its extension to other atomic database services for astrophysical purposes is discussed.

  9. Corneal blindness and xenotransplantation.

    Science.gov (United States)

    Lamm, Vladimir; Hara, Hidetaka; Mammen, Alex; Dhaliwal, Deepinder; Cooper, David K C

    2014-01-01

    Approximately 39 million people are blind worldwide, with an estimated 285 million visually impaired. The developing world shoulders 90% of the world's blindness, with 80% of causative diseases being preventable or treatable. Blindness has a major detrimental impact on the patient, community, and healthcare spending. Corneal diseases are significant causes of blindness, affecting at least 4 million people worldwide. The prevalence of corneal disease varies between parts of the world. Trachoma, for instance, is the second leading cause of blindness in Africa, after cataracts, but is rarely found today in developed nations. When preventive strategies have failed, corneal transplantation is the most effective treatment for advanced corneal disease. The major surgical techniques for corneal transplantation include penetrating keratoplasty (PK), anterior lamellar keratoplasty, and endothelial keratoplasty (EK). Indications for corneal transplantation vary between countries, with Fuchs' dystrophy being the leading indication in the USA and keratoconus in Australia. With the exception of the USA, where EK will soon overtake PK as the most common surgical procedure, PK is the overwhelming procedure of choice. Success using corneal grafts in developing nations, such as Nepal, demonstrates the feasibility of corneal transplantation on a global scale. The number of suitable corneas from deceased human donors that becomes available will never be sufficient, and so research into various alternatives, for example stem cells, amniotic membrane transplantation, synthetic and biosynthetic corneas, and xenotransplantation, is progressing. While each of these has potential, we suggest that xenotransplantation holds the greatest potential for a corneal replacement. With the increasing availability of genetically engineered pigs, pig corneas may alleviate the global shortage of corneas in the near future.

  10. Richner-Hanhart syndrome (tyrosinemia type II): a case report of delayed diagnosis with pseudodendritic corneal lesion.

    Science.gov (United States)

    Iskeleli, Güzin; Bilgeç, Mustafa Değer; Arici, Ceyhun; Atalay, Eray; Oğreden, Tülin; Aydin, Ahmet

    2011-01-01

    Richner-Hanhart syndrome (tyrosinemia type II) is a rare autosomal recessive disease associated with high serum tyrosine levels caused by the deficiency of tyrosine aminotransferase enzyme. We report a 15-year-old female patient with complaints of bilateral photophobia and tearing, which started during the infancy period. Biomicroscopic examination revealed bilateral circular corneal opacities on the inferior quadrant and small dendritic lesions at the center of the circular opacities. Blood tests showed a tyrosine level of 508 micromol/L (normal range: 30-150). On her dermatologic examination, plantar hyperkeratosis and seborrheic dermatitis were noted, and mild mental retardation was detected. One and a half months after the tyrosine- and phenylalanine-restricted diet, her tyrosine level dropped to 395 micromol/L level, her corneal lesions subsided, and a symptomatic relief was achieved. Tyrosinemia type II should be suspected in patients demonstrating dermatologic signs, especially palmoplantar keratosis, associated with bilateral pseudodendritic corneal lesions unresponsive to antiviral therapy.

  11. Design of the opacity spectrometer for opacity measurements at the National Ignition Facility

    Science.gov (United States)

    Ross, P. W.; Heeter, R. F.; Ahmed, M. F.; Dodd, E.; Huffman, E. J.; Liedahl, D. A.; King, J. A.; Opachich, Y. P.; Schneider, M. B.; Perry, T. S.

    2016-11-01

    Recent experiments at the Sandia National Laboratory Z facility have called into question models used in calculating opacity, of importance for modeling stellar interiors. An effort is being made to reproduce these results at the National Ignition Facility (NIF). These experiments require a new X-ray opacity spectrometer (OpSpec) spanning 540 eV-2100 eV with a resolving power E/ΔE > 700. The design of the OpSpec is presented. Photometric calculations based on expected opacity data are also presented. First use on NIF is expected in September 2016.

  12. Refractive corneal surgery - discharge

    Science.gov (United States)

    Nearsightedness surgery - discharge; Refractive surgery - discharge; LASIK - discharge; PRK - discharge ... You had refractive corneal surgery to help improve your vision. This surgery uses a laser to reshape your cornea. It corrects mild-to-moderate nearsightedness, ...

  13. Equine corneal surgery and transplantation.

    Science.gov (United States)

    Denis, Heidi M

    2004-08-01

    Corneal disease is common in equine ophthalmology and requires vigilant monitoring and appropriate therapy to optimize the outcome. Many equine corneal diseases, particularly those that progress rapidly, may benefit from surgical intervention. These include descemetoceles, deep corneal lacerations and ulcers, corneal perforation/iris prolapse, ulcerative keratitis, corneal stromal abscesses, and corneoscleral neoplasia. Indications for corneal transplantation include optical, tectonic, therapeutic, and cosmetic purposes. Corneal transplantation is most often implemented in equine patients for tectonic and therapeutic reasons when a cornea is compromised by corneal stromal abscess, iris prolapse, or neoplasia. This article provides an outline of when to consider surgical intervention for corneal disease, the procedures available and expected outcomes, and how appropriate early surgical intervention can dramatically improve the end result.

  14. Central corneal abscess.

    Science.gov (United States)

    van Bijsterveld, O P

    1976-05-01

    Central corneal abscess developed in the experimental animal after inoculation of biologically active staphylococcal strains in a paracentral epithelial lesion of the cornea. These abscesses did not ulcerate, developed only with high inocula, occurred more frequently in immunized rabbits. A serpiginous type of ulceration did not develop at the site of the initial epithelial lesion nor at any other place in the cornea. Histologically, the lesions consisted of densely packed polymorphonuclear leukocytes between the corneal lamellae.

  15. Effects of diabetic keratopathy on corneal optical density, central corneal thickness, and corneal endothelial cell counts.

    Science.gov (United States)

    Gao, Feng; Lin, Tao; Pan, Yingzhe

    2016-09-01

    Diabetic keratopathy is an ocular complication that occurs with diabetes. In the present study, the effect of diabetic keratopathy on corneal optical density, central corneal thickness, and corneal endothelial cell count was investigated. One hundred and eighty diabetic patients (360 eyes) were enrolled in the study during the period from March, 2012 to March, 2013. The patients were divided into three age groups: 10 years, with 60 patients per group (120 eyes). During the same period, 60 healthy cases (120 eyes) were selected and labeled as the normal control group. The Pentacam was used to measure the corneal optical density, and central corneal thickness. Specular microscopy was used to examine the corneal endothelial cell density. The coefficient of partial correlation was used to control age and correlate the analysis between the corneal optical density, corneal endothelial cell density, and central corneal thickness. The stage of the disease, the medial and intimal corneal optical density and central corneal thickness was analyzed in the diabetes group. The corneal optical density in the diabetes group increased compared with that of the normal control group. The medial and intimal corneal optical density and central corneal thickness were positively correlated with the course of the disease. However, the corneal endothelial cell density was not associated with the course of diabetes. There was a positive association between the medial and intimal corneal optical density and central corneal thickness of the diabetic patients. In conclusion, the results of the present study show that medial and intimal corneal optical density and central corneal thickness were sensitive indicators for early diabetic keratopathy.

  16. Detailed opacity calculations for stellar models

    Science.gov (United States)

    Pain, Jean-Christophe; Gilleron, Franck

    2016-10-01

    We present a state of the art of precise spectral opacity calculations illustrated by stellar applications. The essential role of laboratory experiments to check the quality of the computed data is underlined. We review some X-ray and XUV laser and Z-pinch photo-absorption measurements as well as X-ray emission spectroscopy experiments of hot dense plasmas produced by ultra-high-intensity laser interaction. The measured spectra are systematically compared with the fine-structure opacity code SCO-RCG. Focus is put on iron, due to its crucial role in the understanding of asteroseismic observations of Beta Cephei-type and Slowly Pulsating B stars, as well as in the Sun. For instance, in Beta Cephei-type stars (which should not be confused with Cepheid variables), the iron-group opacity peak excites acoustic modes through the kappa-mechanism. A particular attention is paid to the higher-than-predicted iron opacity measured on Sandia's Z facility at solar interior conditions (boundary of the convective zone). We discuss some theoretical aspects such as orbital relaxation, electron collisional broadening, ionic Stark effect, oscillator-strength sum rules, photo-ionization, or the ``filling-the-gap'' effect of highly excited states.

  17. Solar opacity calculations using the super-transition-array method

    CERN Document Server

    Krief, M; Gazit, D

    2016-01-01

    An opacity model based on the Super-Transition-Array (STA) method for the calculation of monochromatic opacities of local thermodynamic equilibrium plasmas was developed. The model is described and used to calculate spectral opacities for a solar model implementing the recent AGSS09 composition. Calculations are carried throughout the solar radiative zone. The relative contributions of different chemical elements and photon-matter processes to the total Rosseland mean opacity are analyzed in detail. Monochromatic opacities and charge state distributions were compared with the widely used Opacity-Project (OP) code, for several elements near the radiation-convection interface. STA Rosseland opacities for the solar mixture show a very good agreement with OP and the OPAL opacity code, throughout the radiation zone. Finally, an explicit STA calculation of the full AGSS09 photospheric mixture, including all heavy metals was performed. It was shown that due to their extremely low abundance, and despite being very go...

  18. A corneal mold to restore normal corneal dimensions.

    Science.gov (United States)

    Swinger, C A; Kornmehl, E W; York, S; Forman, J S

    1986-01-01

    A corneal mold is described that provides an MK corneal button of normal thickness and curvature from an edematous, post-mortem button. The uniform, processed tissue can then be used for experimental refractive surgery.

  19. Corneal Topography Analysis of Stromal Corneal Dystrophies

    OpenAIRE

    Kocluk, Yusuf; Yalniz-Akkaya, Zuleyha; Burcu, Ayse; Ornek, Firdevs

    2015-01-01

    Objective: The aim was to compare the corneal topography and tomography parameters of macular corneal dystrophy (MCD), granular corneal dystrophy (GCD) and lattice corneal dystrophy (LCD) patients obtained by Scheimpflug imaging system. Methods: The charts, photographs and topography images of patients were reviewed retrospectively. This study included 73 eyes of 73 patients (28 MCD, 20 GCG and 25 LCD patients). Topography images were obtained by Pentacam (Oculus Optikgerate, Wetzlar, Germany...

  20. [Corneal sensibility following epikeratophakia].

    Science.gov (United States)

    Biermann, H; Grabner, G; Baumgartner, I; Reim, M

    1992-07-01

    The postoperative rate of reinnervation following corneal surgery is widely considered to be a useful indicator of the healing process. This study reports the corneal sensitivity of 14 patients following epikeratophakia for different indications (myopia, aphakia and keratoconus) after time periods ranging from 7 to 104 weeks. All transplants were clear at the time of measurement. A newly developed aesthesiometer (using a low electric current for stimulation) was employed. Nine positions on the operated eye were chosen for the measurements, five locations of the non-operated fellow eye served as controls. On the operated eye the corneal sensitivity peripheral to the trephination were significantly reduced at the 9 and 12 o'clock positions as compared to the other eye. The 3 and 6 o'clock locations showed no significant difference. On the epikeratophakia lenticule the sensitivity was significantly reduced at all points, the center showing the largest difference (p less than 0.001). No correlation with age, sex or the indication for the procedure was observed. Although there was a trend of a positive correlation between the postoperative time period and the central corneal sensitivity, the follow-up was too short to reach significant levels. The nearly complete lack of corneal sensitivity, particularly in the center of the transplant is therefore well compatible with its long-time survival, even when the lenticule has been prepared with the cryolathe and lyophilized for transportation.

  1. Opacity of Shock-Generated Argon Plasmas

    Institute of Scientific and Technical Information of China (English)

    王藩侯; 陈敬平; 周显明; 李西军; 经福谦; 孟续军; 孙永盛

    2001-01-01

    Argon plasmas with uniform density and temperature are generated by a planar shock wave through argon gas. The opacities of argon plasma, covering the thermodynamic states at temperatures of 1.4-2.2eV and in densities of 0.0083- 0.015 g/cm3, are investigated by measuring the emitted radiance versus time at several visible wavelengths. Comparison of the measured opacities with those calculated demonstrates that the average atom model can be used well to describe the essential transport behaviour of photons in argon plasma under the abovementioned thermodynamic condition. A simplified and self-consistent method to deduce the reflectivity R(λ) at the baseplate surface is applied. It demonstrates that the values of R(λ) are all around 0.4 in the experiments, which are basically in agreement with those given by Erskine previously (1994 J. Quant. Spectrosc. Radiat.Transfer 51 97).

  2. Revitalizing the Library OPAC: Interface, Searching, and Display Challenges

    Directory of Open Access Journals (Sweden)

    Jia Mi

    2008-03-01

    Full Text Available The behavior of academic library users has drastically changed in recent years. Internet search engines have become the preferred tool over the library online public access catalog (OPAC for finding information. Libraries are losing ground to online search engines. In this paper, two aspects of OPAC use are studied: (1 the current OPAC interface and searching capabilities, and (2 the OPAC bibliographic display. The purpose of the study is to find answers to the following questions: Why is the current OPAC ineffective? What can libraries and librarians do to deliver an OPAC that is as good as search engines to better serve our users? Revitalizing the library OPAC is one of the pressing issues that has to be accomplished.

  3. Extended Opacity Tables with Higher Temperature-Density-Frequency Resolution

    Science.gov (United States)

    Schillaci, Mark; Orban, Chris; Delahaye, Franck; Pinsonneault, Marc; Nahar, Sultana; Pradhan, Anil

    2015-05-01

    Theoretical models for plasma opacities underpin our understanding of radiation transport in many different astrophysical objects. These opacity models are also relevant to HEDP experiments such as ignition scale experiments on NIF. We present a significantly expanded set of opacity data from the widely utilized Opacity Project, and make these higher resolution data publicly available through OSU's portal with dropbox.com. This expanded data set is used to assess how accurate the interpolation of opacity data in temperature-density-frequency dimensions must be in order to adequately model the properties of most stellar types. These efforts are the beginning of a larger project to improve the theoretical opacity models in light of experimental results at the Sandia Z-pinch showing that the measured opacity of Iron disagrees strongly with all current models.

  4. Hohlraum calculations for the NIF opacity platform

    Science.gov (United States)

    Dodd, E. S.; Perry, T. S.; Tregillis, I. L.; Kline, J. L.; Heeter, R. F.; Liedahl, D. A.; Opachich, Y. P.

    2015-11-01

    A summary of initial hohlraum calculations for planned opacity experiments at the National Ignition Facility (NIF) will be given. The purpose of these experiments is to make LTE opacity measurements of iron at the same conditions as previous experiments on Sandia's Z facility: 156 eV and 190 eV. Ongoing discrepancies between opacity data and theory make corroborating data highly important. The target considered in these calculations is a standard cylindrical hohlraum, with diameter 5.75 mm, but baffles have been placed between the laser hot spot and the sample to maintain the iron in LTE. The hohlraum is driven with a 3 ns flat top laser pulse, but limited to 500 kJ and only the outer beams. The inner beams will be used to drive a capsule implosion, which backlights the iron for the absorption measurements. The iron itself is a thin disk, mixed with magnesium as a spectroscopic tracer, and tamped with beryllium to minimize expansion. A description of the experimental set-up will be given. Supported under the US DOE by the Los Alamos National Security, LLC under contract DE-AC52-06NA25396.

  5. Galactic cold cores. V. Dust opacity

    Science.gov (United States)

    Juvela, M.; Ristorcelli, I.; Marshall, D. J.; Montillaud, J.; Pelkonen, V.-M.; Ysard, N.; McGehee, P.; Paladini, R.; Pagani, L.; Malinen, J.; Rivera-Ingraham, A.; Lefèvre, C.; Tóth, L. V.; Montier, L. A.; Bernard, J.-P.; Martin, P.

    2015-12-01

    Context. The project Galactic Cold Cores has carried out Herschel photometric observations of interstellar clouds where the Planck satellite survey has located cold and compact clumps. The sources represent different stages of cloud evolution from starless clumps to protostellar cores and are located in different Galactic environments. Aims: We examine this sample of 116 Herschel fields to estimate the submillimetre dust opacity and to search for variations that might be attributed to the evolutionary stage of the sources or to environmental factors, including the location within the Galaxy. Methods: The submillimetre dust opacity was derived from Herschel data, and near-infrared observations of the reddening of background stars are converted into near-infrared optical depth. We investigated the systematic errors affecting these parameters and used modelling to correct for the expected biases. The ratio of 250 μm and J band opacities is correlated with the Galactic location and the star formation activity. We searched for local variations in the ratio τ(250 μm)/τ(J) using the correlation plots and opacity ratio maps. Results: We find a median ratio of τ(250 μm) /τ(J) = (1.6 ± 0.2) × 10-3, which is more than three times the mean value reported for the diffuse medium. Assuming an opacity spectral index β = 1.8 instead of β = 2.0, the value would be lower by ~ 30%. No significant systematic variation is detected with Galactocentric distance or with Galactic height. Examination of the τ(250 μm) /τ(J) maps reveals six fields with clear indications of a local increase of submillimetre opacity of up to τ(250 μm) /τ(J) ~ 4 × 10-3 towards the densest clumps. These are all nearby fields with spatially resolved clumps of high column density. Conclusions: We interpret the increase in the far-infrared opacity as a sign of grain growth in the densest and coldest regions of interstellar clouds. Planck (http://www.esa.int/Planck) is a project of the European

  6. Anatomic Predictive Factors of Acute Corneal Hydrops in Keratoconus: An Optical Coherence Tomography Study.

    Science.gov (United States)

    Fuentes, Esteban; Sandali, Otman; El Sanharawi, Mohamed; Basli, Elena; Hamiche, Taous; Goemaere, Isabelle; Borderie, Vincent; Bouheraoua, Nacim; Laroche, Laurent

    2015-08-01

    To define the optical coherence tomography (OCT) corneal changes predisposing to acute corneal hydrops among patients with advanced keratoconus. Retrospective cohort study. A total of 191 advanced keratoconic eyes from 191 patients with advanced keratoconus cases were studied. Data collected from patients with advanced keratoconus cases were studied during a minimum period of 24 months of follow-up. High-resolution Fourier-domain corneal OCT (5 μm of axial resolution) and corneal topography were performed every 4 months during the follow-up. Several anatomic features at the keratoconus cone were analyzed with OCT, including epithelial and stromal thicknesses, the aspect of Bowman's layer, the presence of Vogt's striae, and stromal opacities. A comparative analysis between anatomic corneal features in eyes that developed corneal hydrops and those that did not develop this complication during the follow-up was performed. Evaluation of anatomic corneal changes at risk of developing a corneal hydrops on the basis of OCT findings. Eleven cases of corneal hydrops (5.8%) occurred in our series during a mean follow-up of 30 months (24-36 months). All of these patients were male and younger (23.7±5.9 years) than patients with no acute keratoconus (32.7±11.3 years). Increased epithelial thickening with stromal thinning at the conus and the presence of anterior hyperreflectives at the Bowman's layer level were significantly associated with corneal hydrops, whereas the presence of corneal scarring was a preventive factor. At the healing stage, a pan-stromal scar occurs, with a significant stromal thickening and cornea flattening. Increased epithelial thickening, stromal thinning at the keratoconus cone, anterior hyperreflectives at the Bowman's layer level, and the absence of stromal scarring are associated with a high risk of developing corneal hydrops. These aspects should be taken into account by the clinician in the evaluation of keratoconus eyes and in the planning of

  7. Mean gas opacity for circumstellar environments and equilibrium temperature degeneracy

    CERN Document Server

    Malygin, M G; Klahr, H; Dullemond, C P; Henning, Th

    2014-01-01

    In a molecular cloud dust opacity typically dominates over gas opacity, yet in the vicinities of forming stars dust is depleted, and gas is the sole provider of opacity. In the optically thin circumstellar environments the radiation temperature cannot be assumed to be equal to the gas temperature, hence the two-temperature Planck means are necessary to calculate the radiative equilibrium. By using the two-temperature mean opacity one does obtain the proper equilibrium gas temperature in a circumstellar environment, which is in a chemical equilibrium. A careful consideration of a radiative transfer problem reveals that the equilibrium temperature solution can be degenerate in an optically thin gaseous environment. We compute mean gas opacities based on the publicly available code DFSYNTHE by Kurucz and Castelli. We performed the calculations assuming local thermodynamic equilibrium and an ideal gas equation of state. The values were derived by direct integration of the high-resolution opacity spectrum. We prod...

  8. IPOPv2 online service for the generation of opacity tables

    Science.gov (United States)

    Delahaye, Franck; Zwölf, Carlo Maria; Zeippen, Claude J.; Mendoza, Claudio

    2016-03-01

    In the framework of the present phase - IPOPv2 - of the international Opacity Project (OP), a new web service has been implemented based on the latest release of the OP opacities. The user may construct online opacity tables to be conveniently included in stellar evolution codes in the format most commonly adopted by stellar physicists, namely the OPAL format. This facility encourages the use and comparison of both the OPAL and OP data sets in applications. The present service allows for the calculation of multi-element mixtures containing the 17 species (H, He, C, N, O, Ne, Na, Mg, Al, Si, S, Ar, Ca, Cr, Mn, Fe and Ni) considered by the OP, and underpins the latest release of OP opacities. This new service provides tables of Rosseland mean opacites using OP atomic data. We provide an alternative to the OPAL opacity services allowing direct comparison as well as study of the effect of uncertainties in stellar modeling due to mean opacities.

  9. IPOPv2 online service for the generation of opacity tables

    CERN Document Server

    Delahaye, F; Zeippen, C; Mendoza, C

    2015-01-01

    In the framework of the present phase -- IPOPv2 -- of the international Opacity Project (OP), a new web service has been implemented based on the latest release of the OP opacities. The user may construct online opacity tables to be conveniently included in stellar evolution codes in the format most commonly adopted by stellar physicists, namely the OPAL format. This facility encourages the use and comparison of both the OPAL and OP data sets in applications. The present service allows for the calculation of multi-element mixtures containing the 17 species (H, He, C, N, O, Ne, Na, Mg, Al, Si, S, Ar, Ca, Cr, Mn, Fe and Ni) considered by the OP, and underpins the latest release of OP opacities. This new service provides tables of Rosseland mean opacites using OP atomic data. We provide an alternative to the OPAL opacity services allowing direct comparison as well as study of the effect of uncertainties in stellar modeling due to mean opacities.

  10. Solar Opacity Calculations Using the Super-transition-array Method

    Science.gov (United States)

    Krief, M.; Feigel, A.; Gazit, D.

    2016-04-01

    A new opacity model has been developed based on the Super-Transition-Array (STA) method for the calculation of monochromatic opacities of plasmas in local thermodynamic equilibrium. The atomic code, named STAR (STA-Revised), is described and used to calculate spectral opacities for a solar model implementing the recent AGSS09 composition. Calculations are carried out throughout the solar radiative zone. The relative contributions of different chemical elements and atomic processes to the total Rosseland mean opacity are analyzed in detail. Monochromatic opacities and charge-state distributions are compared with the widely used Opacity Project (OP) code, for several elements near the radiation-convection interface. STAR Rosseland opacities for the solar mixture show a very good agreement with OP and the OPAL opacity code throughout the radiation zone. Finally, an explicit STA calculation was performed of the full AGSS09 photospheric mixture, including all heavy metals. It was shown that, due to their extremely low abundance, and despite being very good photon absorbers, the heavy elements do not affect the Rosseland opacity.

  11. SOLAR OPACITY CALCULATIONS USING THE SUPER-TRANSITION-ARRAY METHOD

    Energy Technology Data Exchange (ETDEWEB)

    Krief, M.; Feigel, A.; Gazit, D., E-mail: menahem.krief@mail.huji.ac.il [The Racah Institute of Physics, The Hebrew University, 91904 Jerusalem (Israel)

    2016-04-10

    A new opacity model has been developed based on the Super-Transition-Array (STA) method for the calculation of monochromatic opacities of plasmas in local thermodynamic equilibrium. The atomic code, named STAR (STA-Revised), is described and used to calculate spectral opacities for a solar model implementing the recent AGSS09 composition. Calculations are carried out throughout the solar radiative zone. The relative contributions of different chemical elements and atomic processes to the total Rosseland mean opacity are analyzed in detail. Monochromatic opacities and charge-state distributions are compared with the widely used Opacity Project (OP) code, for several elements near the radiation–convection interface. STAR Rosseland opacities for the solar mixture show a very good agreement with OP and the OPAL opacity code throughout the radiation zone. Finally, an explicit STA calculation was performed of the full AGSS09 photospheric mixture, including all heavy metals. It was shown that, due to their extremely low abundance, and despite being very good photon absorbers, the heavy elements do not affect the Rosseland opacity.

  12. Corneal Neurotoxicity Due to Topical Benzalkonium Chloride

    OpenAIRE

    Sarkar, Joy; Chaudhary, Shweta; Namavari, Abed; Ozturk, Okan; Chang, Jin-Hong; Yco, Lisette; Sonawane, Snehal; Khanolkar, Vishakha; Hallak, Joelle; Jain, Sandeep

    2012-01-01

    Topical application of benzalkonium chloride (BAK) to the eye causes dose-related corneal neurotoxicity. Corneal inflammation and reduction in aqueous tear production accompany neurotoxicity. Cessation of BAK treatment leads to recovery of corneal nerve density.

  13. Genetics of corneal endothelial dystrophies

    Indian Academy of Sciences (India)

    Chitra Kannabiran

    2009-12-01

    The corneal endothelium maintains the level of hydration in the cornea. Dysfunction of the endothelium results in excess accumulation of water in the corneal stroma, leading to swelling of the stroma and loss of transparency. There are four different corneal endothelial dystrophies that are hereditary, progressive, non-inflammatory disorders involving dysfunction of the corneal endothelium. Each of the endothelial dystrophies is genetically heterogeneous with different modes of transmission and/or different genes involved in each subtype. Genes responsible for disease have been identified for only a subset of corneal endothelial dystrophies. Knowledge of genes involved and their function in the corneal endothelium can aid understanding the pathogenesis of the disorder as well as reveal pathways that are important for normal functioning of the endothelium.

  14. First solar models with OPAS opacity tables

    CERN Document Server

    Pennec, Maëlle Le; Salmon, Sébastien; Blancard, Christophe; Cossé, Philippe; Faussurier, Gérald; Mondet, Guillaume

    2015-01-01

    Stellar seismology appears more and more as a powerful tool for a better determination of the fundamental properties of solar-type stars. However the particular case of Sun is still challenging. The helioseismic sound speed determination continues to disagree with the Standard Solar Model (SSM) prediction for about a decade, questioning the reliability of this model. One of the sources of uncertainty could be in the treatment of the transport of radiation from the solar core to the surface. In this letter, we use the new OPAS opacity tables, recently available for solar modelling, to address this issue. We discuss first the peculiarities of these tables, then we quantify their impact on the solar sound speed and density profiles using the reduced OPAS tables taken on the grids of the OPAL ones. We use the two evolution codes MESA and CLES that led to similar conclusions in the solar radiative zone. In comparison to commonly used OPAL opacity tables, the new solar models computed, for the most recent photosphe...

  15. Bilateral acute corneal calcification.

    Science.gov (United States)

    Freddo, T F; Leibowitz, H M

    1985-04-01

    A 38-year-old man with brittle, juvenile onset diabetes mellitus and bilateral severe dry eyes with recurrent corneal ulcers developed atypical band-shaped calcifications of both corneas during a 24-hour period. Serum calcium, phosphate, and carbon dioxide levels all were within normal limits. The patient was mildly uremic but was not in renal failure. When EDTA chelation failed to clear the deposits, partial keratectomies were performed in both eyes and the specimens were examined by light and electron microscopy, including energy dispersive x-ray analysis. Microscopic studies revealed an atypical calcific keratopathy which involved neither Bowman's layer nor the most superficial stromal lamellae. The deposits were confined to deeper lamellae in the anterior stroma and by electron microscopy were composed of extracellular crystalline aggregates. Energy dispersive x-ray analysis of these aggregates confirmed the presence of calcium and phosphate. Corneal dessication appeared to be a major contributing factor in the rapid formation of these deposits.

  16. Corneal blindness: prevention, treatment and rehabilitation

    Directory of Open Access Journals (Sweden)

    Matthew J Burton

    2009-12-01

    Full Text Available Blindness from corneal disease is a major ophthalmic public health problem. There are three important elements to addressing corneal blindness: prevention, treatment, and rehabilitation.

  17. Ketamine/Xylazine-Induced Corneal Damage in Mice.

    Directory of Open Access Journals (Sweden)

    Demelza Koehn

    Full Text Available We have observed that the commonly used ketamine/xylazine anesthesia mix can induce a focally severe and permanent corneal opacity. The purpose of this study was to establish the clinical and histological features of this deleterious side effect, its sensitivity with respect to age and anesthesia protocol, and approaches for avoiding it.Young C57BL/6J, C57BLKS/J, and SJL/J mice were treated with permutations of anesthesia protocols and compared using slit-lamp exams, optical coherence tomography, histologic analyses, and telemetric measurements of body temperature.Ketamine/xylazine induces corneal damage in mice with a variable frequency. Among 12 experimental cohorts, corneal damage associated with ketamine/xylazine was observed in 9 of them. Despite various treatments to avoid corneal dehydration during anesthesia, the frequency of corneas experiencing damage among responding cohorts was 42% (26% inclusive of all cohorts, which is significantly greater than the natural prevalence (5%. The damage was consistent with band keratopathy. It appeared as a white or gray horizontal band located proximal to the pupil and was positive for subepithelial calcium deposition with von Kossa stain.The sum of our clinical and histological observations is consistent with ketamine/xylazine-induced band keratopathy in mice. This finding is relevant for mouse studies involving the eye and/or vision-dependent behavioral assays, which would both be prone to artifact without appreciation of the damage caused by ketamine/xylazine anesthesia. Use of yohimbine is suggested as a practical means of avoiding this complication.

  18. [Therapy for systemic metabolic disorders based on the detection of basic corneal landmarks in childhood].

    Science.gov (United States)

    Lisch, W; Pitz, S; Geerling, G

    2013-06-01

    Many systemic lysosomal storage disorders show basic corneal opacities already in childhood. The lysosome is a cell organelle, produced by Golgi's apparatus, that is surrounded by a membrane and contains hydrolytic enzymes that break down food molecules, especially proteins and other complex molecules. The ophthalmologist's precise diagnosis of corneal clouding at the slit-lamp may reveal the correct interpretation of the specific lysosomal storage disorder. It is very important to diagnose such diseases as soon as possible because today the development of systemic enzymatic therapies has broadened the therapeutic armamentarium for the current standard of care. The following corneal landmarks of systemic storage diseases and of the modern systemic therapy are presented: cornea verticillata in Fabry's disease, periodic infusion of alpha-galactosidase a; Kayser-Fleischer's ring in Wilson's disease, zinc, trienetin, low copper diet; multiple, punctiform crystals in cystinosis, cysteamine, Raptor RP 103(DR cysteamine) that reduces the cytotoxity in form of continous dissolving of cystine from lysosome, renal transplantation, haematopoietic stem cell transplantation; peripheral ring, but not true lipid arc, and moderate stromal haze in LCAT-deficiency, injection of recombinant enzyme or of encapsulated LCAT-secreting cells; diffuse stromal haze in mucopolysaccharidoses (MPS). Enzyme replacement therapy is currently indicated for MPS I, MPS II, and MPS VI, haematopoietic stem cell transplantation; painful, bilateral pseudo-dendritic opacities in tyrosinemia type II (eponym: Richner-Hanhart syndrome), low phenylalanine and tyrosine diet result in complete disappearance of corneal alterations with a consecutive painfree period. Strict diet during the whole life is necessary to prevent corneal recurrences and the occurrence of palmo-plantar keratoses. Such therapies can enable the patient to lead an otherwise normal life for decades.

  19. Calculation of Free-Free Opacities

    Science.gov (United States)

    Bhatia, A. K.; Maiden, D.; Ritchie, A. B., Jr.

    2003-01-01

    Free-free absorption is an important contribution to the opacity for radiation transport through hot materials Temperatures can be as high as several keV, such that it becomes a computational challenge to solve the Schrodinger equation efficiently for rapidly oscillating continuum functions for high angular momenta. Several groups\\footnots, including ours, have studied the phase amplitude solution (PAS) of the Schrodinger equation, in which one solves equations for the wave function amplitude and phase, which are: smooth functions of the electron energy. It is also important to have an accurate Schroudinger benchmark for the development of the PAS method. We present results for dipole matrix elements, Gaunt factors, and cross sections for the absorption of radiation at various energies for Cs XIX at temperature=100 eV and density=0.187 g/cc for our newly developed PAS and Schrodinger benchmark.

  20. Surgery for Pulmonary Multiple Ground Glass Opacities

    Directory of Open Access Journals (Sweden)

    Qun WANG

    2016-06-01

    Full Text Available The incidence of pulmonary ground glass opacity (GGO has been increasing in recent years, with a great number of patients having multiple GGOs. Unfortunately, the management of multiple GGOs is still controversial. Pulmonary GGO is a radiological term, consisting of different pathological types. Some of the GGOs are early-staged lung cancer. GGO is an indolent nodule, only a small proportion of GGOs change during observation, which does not influence the efficacy of surgery. . The timing of surgery for multiple GGOs mainly depends on the predominant nodule and surgery is recommended if the solid component of the predominant nodule >5 mm. Either lobectomy or sub-lobectomy is feasible. GGOs other than the predominant nodule can be left unresected. Multiple GGOs with high risk factors need mediastinal lymph node dissection or sampling.

  1. An opacity-sampled treatment of water vapor

    Science.gov (United States)

    Alexander, David R.; Augason, Gordon C.; Johnson, Hollis R.

    1989-01-01

    Although the bands of H2O are strong in the spectra of cool stars and calculations have repeatedly demonstrated their significance as opacity sources, only approximate opacities are currently available, due both to the difficulty of accounting for the millions of lines involved and to the inadequacy of laboratory and theoretical data. To overcome these obstacles, a new treatment is presented, based upon a statistical representation of the water vapor spectrum derived from available laboratory data. This statistical spectrum of water vapor employs an exponential distribution of line strengths and random positions of lines whose overall properties are forced to reproduce the mean opacities observed in the laboratory. The resultant data set is then treated by the opacity-sampling method exactly as are all other lines, both molecular and atomic. Significant differences are found between the results of this improved treatment and the results obtained with previous treatments of water-vapor opacity.

  2. A New Generation of Los Alamos Opacity Tables

    CERN Document Server

    Colgan, J; Magee, N H; Sherrill, M E; Abdallah,, J; Hakel, P; Fontes, C J; Guzik, J A; Mussack, K A

    2016-01-01

    We present a new, publicly available, set of Los Alamos OPLIB opacity tables for the elements hydrogen through zinc. Our tables are computed using the Los Alamos ATOMIC opacity and plasma modeling code, and make use of atomic structure calculations that use fine-structure detail for all the elements considered. Our equation-of-state (EOS) model, known as ChemEOS, is based on the minimization of free energy in a chemical picture and appears to be a reasonable and robust approach to determining atomic state populations over a wide range of temperatures and densities. In this paper we discuss in detail the calculations that we have performed for the 30 elements considered, and present some comparisons of our monochromatic opacities with measurements and other opacity codes. We also use our new opacity tables in solar modeling calculations and compare and contrast such modeling with previous work.

  3. Corneal Densitometry for Quantification of Corneal Deposits in Monoclonal Gammopathies.

    Science.gov (United States)

    Enders, Philip; Holtick, Udo; Schaub, Friederike; Tuchscherer, Armin; Hermann, Manuel M; Scheid, Christoph; Cursiefen, Claus; Bachmann, Björn O

    2017-04-01

    To assess the capability of Scheimpflug-based densitometry of the cornea to quantify light chain deposits in patients with active monoclonal gammopathies. This is a case-control study in which data from a leading tertiary university center in myeloma care were analyzed. Ten eyes of 5 patients with monoclonal gammopathy and 26 eyes of 13 healthy controls undergoing clinical evaluation and Scheimpflug-based measurements were included in the study. The main outcome measures were densitometry data of the 4 corneal layers-anterior layer (AL), central layer (CL), posterior layer, and total layer (TL)-in 4 different annuli (central annular zone 0-2 mm, intermediate annular zone 2-6 mm, peripheral annular zone 6-10 mm, and total annular zone 0-12 mm). In 8 eyes of 4 patients with IgG-based gammopathy, corneal light backscatter was highest in the AL and decreased with increasing corneal depth. The peripheral annular zone showed a higher densitometry value compared with the corneal center. Compared with healthy controls, the AL (P < 0.001), the CL (P < 0.001), and the TL (P < 0.001) had significantly higher corneal light backscatter in patients with gammopathy in the total and the peripheral annular zones. In one patient with predominantly IgA-based disease, corneal light backscatter was not elevated. Scheimpflug-based densitometry of the cornea is able to quantify opacification by immunoglobulin G light chain deposits in monoclonal gammopathies. This noninvasive technique can complement presently used in vivo confocal microscopy and corneal photography to objectivize corneal changes. Densitometry might allow monitoring of corneal immunoglobulin deposits in follow-up examinations.

  4. Rosseland and Flux Mean Opacities for Compton Scattering

    Science.gov (United States)

    Poutanen, Juri

    2017-02-01

    Rosseland mean opacity plays an important role in theories of stellar evolution and X-ray burst models. In the high-temperature regime, when most of the gas is completely ionized, the opacity is dominated by Compton scattering. Our aim here is to critically evaluate previous works on this subject and to compute the exact Rosseland mean opacity for Compton scattering over a broad range of temperature and electron degeneracy parameter. We use relativistic kinetic equations for Compton scattering and compute the photon mean free path as a function of photon energy by solving the corresponding integral equation in the diffusion limit. As a byproduct we also demonstrate the way to compute photon redistribution functions in the case of degenerate electrons. We then compute the Rosseland mean opacity as a function of temperature and electron degeneracy and present useful approximate expressions. We compare our results to previous calculations and find a significant difference in the low-temperature regime and strong degeneracy. We then proceed to compute the flux mean opacity in both free-streaming and diffusion approximations, and show that the latter is nearly identical to the Rosseland mean opacity. We also provide a simple way to account for the true absorption in evaluating the Rosseland and flux mean opacities.

  5. Replicating the Z iron opacity experiments on the NIF

    Science.gov (United States)

    Perry, T. S.; Heeter, R. F.; Opachich, Y. P.; Ross, P. W.; Kline, J. L.; Flippo, K. A.; Sherrill, M. E.; Dodd, E. S.; DeVolder, B. G.; Cardenas, T.; Archuleta, T. N.; Craxton, R. S.; Zhang, R.; McKenty, P. W.; Garcia, E. M.; Huffman, E. J.; King, J. A.; Ahmed, M. F.; Emig, J. A.; Ayers, S. L.; Barrios, M. A.; May, M. J.; Schneider, M. B.; Liedahl, D. A.; Wilson, B. G.; Urbatsch, T. J.; Iglesias, C. A.; Bailey, J. E.; Rochau, G. A.

    2017-06-01

    X-ray opacity is a crucial factor of all radiation-hydrodynamics calculations, yet it is one of the least validated of the material properties in the simulation codes. Recent opacity experiments at the Sandia Z-machine have shown up to factors of two discrepancies between theory and experiment, casting doubt on the validity of the opacity models. Therefore, a new experimental opacity platform is being developed on the National Ignition Facility (NIF) not only to verify the Z-machine experimental results but also to extend the experiments to other temperatures and densities. The first experiments will be directed towards measuring the opacity of iron at a temperature of ∼160 eV and an electron density of ∼7 × 1021 cm-3. Preliminary experiments on NIF have demonstrated the ability to create a sufficiently bright point backlighter using an imploding plastic capsule and also a hohlraum that can heat the opacity sample to the desired conditions. The first of these iron opacity experiments is expected to be performed in 2017.

  6. Linear opacities on HRCT in bronchiolitis obliterans organising pneumonia

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, J.M.; Flower, C.D.R. [Dept. of Radiology, Addenbrookes Hospital, Univ. of Cambridge (United Kingdom); Schnyder, P.; Leuenberger, P. [Depts. of Radiology and Medicine, University Hospital, CHUV, Lausanne (Switzerland); Verschakelen, J. [Dept. of Radiology, University Hospital, Leuven (Belgium)

    1999-07-01

    The aim of this study was to report the high-resolution computed tomography (HRCT) appearances of linear opacities that may occur in isolation or in combination with other changes in bronchiolitis obliterans organising pneumonia (BOOP). Eleven patients with BOOP and linear opacities on HRCT were identified at three independent teaching hospitals. The HRCT images and clinical course of each patient were reviewed. Two distinct types of linear opacity were identified. The type-1 opacity extended in a radial manner along the line of the bronchi towards the pleura and was usually intimately related to bronchi. The type-2 opacity occurred in a sub-pleural location and bore no relationship to the bronchi. Both types occurred most commonly in the lower lobes, frequently were associated with multi-focal areas of consolidation and usually completely resolved with treatment. There was no associated bronchiectasis, irreversible volume loss or a reticular or honeycomb pattern. In 2 patients linear opacities were the sole abnormality on HRCT. Bronchiolitis obliterans organising pneumonia may occur in a pure ''linear form'' or HRCT may demonstrate linear opacities in addition to multi-focal consolidation. (orig.)

  7. Computing NLTE Opacities -- Node Level Parallel Calculation

    Energy Technology Data Exchange (ETDEWEB)

    Holladay, Daniel [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-09-11

    Presentation. The goal: to produce a robust library capable of computing reasonably accurate opacities inline with the assumption of LTE relaxed (non-LTE). Near term: demonstrate acceleration of non-LTE opacity computation. Far term (if funded): connect to application codes with in-line capability and compute opacities. Study science problems. Use efficient algorithms that expose many levels of parallelism and utilize good memory access patterns for use on advanced architectures. Portability to multiple types of hardware including multicore processors, manycore processors such as KNL, GPUs, etc. Easily coupled to radiation hydrodynamics and thermal radiative transfer codes.

  8. Calculation and Analysis of Mean Opacity of Gold Mixtures

    Institute of Scientific and Technical Information of China (English)

    YAN An-ying; JIANG Ming; CHENG Xin-lu; YANG Xiang-dong

    2007-01-01

    A screened hydrogenic model for l splitting (SHML) is used to calculate the Rosseland mean opacities of high-Z Au, Ta, Yb, Ho, Gd, Sm, Nd, Sn, Ag plasmas and mixtures of gold and these elements at high temperature (T=200-400eV) and dense (ρ=1g/cm3).From the calculated Rosseland mean opacities of the mixtures, Au-Nd seems to be a better choice than other mixtures.Simultaneously, the reason that the mean opacities of mixture of Au-Sn decrease slightly when T=400eV is analyzed.

  9. Opacity Calculations for Non-Local Thermodynamic Equilibrium Mixtures

    Institute of Scientific and Technical Information of China (English)

    吴泽清; 韩国兴; 逄锦桥

    2002-01-01

    Based on the average atom model, a non-local thermodynamic equilibrium (non-LTE) model is developed to calculate opacity for mixtures. This model could be applied to high-Z problems. The mean ionization degrees of SiO2 of the present calculation are slightly higher compared with another model for mixtures. As an example, the opacity of Au and Nd mixture is calculated. The results show concrete non-LTE effects and the increase in opacity of the mixture is shown clearly.

  10. In vivo confocal microscopy of an apparent deep stroma corneal dystrophy: a case report

    Science.gov (United States)

    2009-01-01

    A 41-year-old white woman was referred to our Department to rule out the presence of a Fuch's corneal dystrophy. On slit-lamp biomicroscopy, small bilateral punctuate opacities appearing mostly in the posterior stroma were observed, suggesting a differential diagnosis of pre-Descemet's dystrophy as opposed to Cornea Farinata. Confocal microscopy in the central cornea of both eyes revealed the normal appearance of superficial and basal epithelial layers. However throughout the full thickness of the cornea fine highly refractive granules, localized both in the keratocytes cytoplasm and in the stroma matrix were noted. In both eyes abnormal polymegatism and pleomorphism was observed. PMID:20062640

  11. Endoscopy-guided vitreoretinal surgery following penetrating corneal injury: a case report

    Directory of Open Access Journals (Sweden)

    Motoko Kawashima

    2010-08-01

    Full Text Available Motoko Kawashima1, Shinichi Kawashima2, Murat Dogru1,3, Makoto Inoue4, Jun Shimazaki1,51Department of Ophthalmology, Tokyo Dental College, Chiba, Japan; 2Department of Ophthalmology, International University of Health and Welfare, Tokyo, Japan; 3Department of Ocular Surface and Visual Optics, Keio University School of Medicine, Tokyo, Japan; 4Kyorin Eye Center, Tokyo, Japan; 5Department of Ophthalmology, Keio University School of Medicine, Tokyo, JapanIntroduction: Severe ocular trauma requires emergency surgery, and a fresh corneal graft may not always be available. We describe a case of perforating eye injury with corneal ­opacity, suspected endophthalmitis, and an intraocular foreign body. The patient was successfully treated with a two-step procedure comprising endoscopy-guided vitrectomy followed by corneal transplantation. This surgical technique offers a good option to vitrectomy with simultaneous keratoplasty in emergency cases where no graft is immediately available and there is the ­possibility of infection due to the presence of a foreign body.Case presentation: A 55-year-old Japanese woman was referred to our hospital with a ­perforating corneal and lens injury sustained with a muddy ferrous rod. Primary corneal sutures and lensectomy were performed immediately. Vitreoretinal surgery was required due to ­suspected endophthalmitis, vitreous hemorrhage, retinal detachment, dialysis and necrosis of the peripheral retina. Instead of conventional vitrectomy, endoscopy-guided vitreous surgery was performed with the Solid Fiber Catheter AS-611 (FiberTech, Tokyo, Japan due to the presence of corneal opacity and the unavailability of a donor cornea. The retina was successfully attached with the aid of a silicon oil tamponade. Following removal of the silicon oil at 3 months after surgery, penetrating keratoplasty and intraocular lens implantation with ciliary sulcus suture fixation were performed. At 6 months after penetrating

  12. Rosseland and flux mean opacities for Compton scattering

    CERN Document Server

    Poutanen, Juri

    2016-01-01

    Rosseland mean opacity plays an important role in theories of stellar evolution and X-ray burst models. In the high-temperature regime, when most of the gas is completely ionized, the opacity is dominated by Compton scattering. Our aim here is to critically evaluate previous works on this subject and to compute exact Rosseland mean opacity for Compton scattering in a broad range of temperatures and electron degeneracy parameter. We use relativistic kinetic equations for Compton scattering and compute the photon mean free path as a function of photon energy by solving the corresponding integral equation in the diffusion limit. As a byproduct we also demonstrate the way to compute photon redistribution functions in case of degenerate electrons. We then compute the Rosseland mean opacity as a function of temperature and electron degeneracy. We compare our results to the previous calculations and find a significant difference in the low-temperature regime and strong degeneracy. We find useful analytical expressio...

  13. Is Seeing Believing? Consumer Responses to Opacity of Product Packaging

    National Research Council Canada - National Science Library

    Sucharita Chandran; Rishtee Kumar Batra; Benjamin Lawrence

    2009-01-01

      Prior studies have shown that product and packaging design influences consumer reactions and purchase behaviors, however, research has neglected to examine a package's opacity or lack of transparency...

  14. Opacity Experiments At The National Ignition Facility (NIF)

    Science.gov (United States)

    Perry, T. S.; Kline, J. L.; Flippo, K. A.; Sherrill, M. E.; Dodd, E. S.; Devolder, B. G.; Urbatsch, T. J.; Heeter, R. F.; Schneider, M. B.; Liedahl, D. A.; Wilson, B. G.; Iglesias, C. A.; Opachich, Y. P.; Ross, P. W.; Bailey, J. E.; Rochau, G. A.

    2016-10-01

    X-ray opacities are essential to the radiation-hydrodynamic simulations used to model astrophysical systems or inertial confinement fusion experiments. Recent opacity experiments have shown up to a factor of two discrepancy between theory and experiment. To address this issue a new experimental opacity platform is being developed on the NIF to crosscheck the recent results. The first experiments, starting in 2017, will begin by measuring the opacity of iron at a temperature of 160 eV and an electron density of 7x1021 cm-3. This and several following presentations will describe this effort. This work was performed under the auspices of the U.S. Department of Energy by Los Alamos National Lab under Contract DE-AC52-06NA25396.

  15. [The effect of Solcoseryl eye gel in combination with neomycin and bacitracin on the healing of corneal lesions after foreign body removal].

    Science.gov (United States)

    Haydon, P

    1983-09-01

    The effect of Solcoseryl on the healing rate of corneal lesions after foreign body removal was assessed in a double-blind study. Solcoseryl is a protein-free hemodialysate which is widely used to stimulate tissue repair processes. The healing rate was determined by means of photodocumentation which was complete in 82 out of 92 cases. The Solcoseryl group showed in significantly faster healing rate and a lower tendency to development of corneal opacities than the control group. No side-effects were observed which could be attributed to either of the drugs used in the study.

  16. Experiment to measure oxygen opacity at high density and temperature

    Science.gov (United States)

    Keiter, Paul; Mussack, Katie; Orban, Chris; Colgan, James; Ducret, Jean-Eric; Fontes, Christopher J.; Guzik, Joyce Ann; Heeter, Robert F.; Kilcrease, Dave; Le Pennec, Maelle; Mancini, Roberto; Perry, Ted; Turck-Chièze, Sylvaine; Trantham, Matt

    2017-06-01

    In recent years, there has been a debate over the abundances of heavy elements (Z >2) in the solar interior. Recent solar atmosphere models [Asplund 2009] find a significantly lower abundance for C, N, and O compared to models used roughly a decade ago. This discrepancy has led to an investigation of opacities through laboratory experiments and improved opacity models for many of the larger contributors to the sun’s opacity, including iron and oxygen. Recent opacity measurements of iron disagree with opacity model predictions [Bailey et al, 2015]. Although these results are still controversial, repeated scrutiny of the experiment and data has not produced a conclusive reason for the discrepancy. New models have been implemented in the ATOMIC opacity code for C, O and Fe to address the solar abundance issue [Colgan, 2013]. Armstrong et al [2014] have also implemented changes in the ATOMIC code for low-Z elements. However, no data currently exists to test the low-Z material models in the regime relevant to the solar convection zone. We present an experimental design using the opacity platform developed at the National Ignition Facility to study the oxygen opacity at densities and temperatures near the solar convection zone conditions.This work is funded by the U.S. DOE, through the NNSA-DS and SC-OFES Joint Program in HEDPLP, grant No. DE-NA0001840, and the NLUF Program, grant No. DE-NA0000850, and through LLE, University of Rochester by the NNSA/OICF under Agreement No. DE-FC52-08NA28302.

  17. Analytical expressions for radiative opacities of low Z plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Rubiano, J G; Martel, P; Gil, J M; Rodriguez, R; Florido, R; Mendoza, M A [Departamento de Fisica, Universidad de Las Palmas de GC, Las Palmas de GC (Spain); Minguez, E, E-mail: jgarcia@dfis.ulpgc.e [Instituto de Fusion Nuclear (DENIM), Universidad Politecnica de Madrid, Madrid (Spain)

    2010-08-01

    In this work we obtain analytical expressions for the radiative opacity of several low Z plasmas (He, Li, Be, and B) in a wide range of temperatures and densities. These formulas are obtained by fitting the proposed expression to mean opacities data calculated by using the code ABAKO/ RAPCAL. This code computes the radiative properties of plasmas, both in LTE and NLTE conditions, under the detailed-level-accounting approach. It has been successfully validated in the range of interest in previous works.

  18. [Methods for sealing of corneal perforations].

    Science.gov (United States)

    Samoilă, O; Totu, Lăcrămioara; Călugăru, M

    2012-01-01

    A variety of corneal pathology can lead to corneal ulcers and perforations. A deep corneal ulcer may need surgical treatment to allow good volume restoration and reepithelisation. Corneal perforation must be sealed and when the perforation is large, the task of repairing the defect can be underwhelming. The elegant solution is the corneal transplant, but this is not always readily available, especially in undeveloped countries. We present here two cases with different solutions to seal the perforated cornea: the first one has a large peripheral defect and it is successfully sealed with scleral patch and the second one is central with small perforation and is successfully sealed with multilayered amniotic membrane. Both cases are followed for over 12 months and demonstrate good corneal restoration (both on clinical examination and corneal topography). Sclera and amniotic membrane can be used to seal corneal defects when corneal transplant is not readily available.

  19. Corneal collagen crosslinking: a systematic review.

    Science.gov (United States)

    Sorkin, Nir; Varssano, David

    2014-01-01

    Keratoconus (KCN) is an ectatic disorder with progressive corneal thinning and a clinical picture of corneal protrusion, progressive irregular astigmatism, corneal fibrosis and visual deterioration. Other ectatic corneal disorders include: post-LASIK ectasia (PLE) and pellucid marginal degeneration (PMD). Corneal crosslinking (CXL) is a procedure whereby riboflavin sensitization with ultraviolet A radiation induces stromal crosslinks. This alters corneal biomechanics, causing an increase in corneal stiffness. In recent years, CXL has been an established treatment for the arrest of KCN, PLE and PMD progression. CXL has also been shown to be effective in the treatment of corneal infections, chemical burns, bullous keratopathy and other forms of corneal edema. This is a current review of CXL - its biomechanical principles, the evolution of CXL protocols in the past, present and future, indications for treatment, treatment efficacy and safety.

  20. Corneal Topographic Changes After Eyelid Ptosis Surgery.

    Science.gov (United States)

    Savino, Gustavo; Battendieri, Remo; Riso, Monica; Traina, Salvatore; Poscia, Andrea; DʼAmico, Giovanni; Caporossi, Aldo

    2016-04-01

    To evaluate the corneal topography and the topographic changes after ptosis surgery on patients affected by congenital and acquired blepharoptosis. Twenty eyes of 17 patients affected by acquired and congenital ptosis underwent surgical correction through anterior levator complex tightening. Computerized tomography (Syrius Sistem; CSO) was used to analyze any change in corneal astigmatism (CYL), simulated keratometry, anterior corneal symmetry index front, apical keratometry front, and central corneal thickness. Visual acuity, margin reflex distance, and levator function were also measured. After surgical ptosis repair, corneal topography demonstrated a reduction in average keratometry of 0.15 ± 0.47 diopters (D) and in corneal astigmatism of 0.26 ± 1.12 D. Significant differences were found in apical keratometry front (-1.84 ± 1.76 D) and in best-corrected visual acuity (-0.18 ± 0.06 logMAR) in the postoperative examinations. Central corneal thickness did not show significant differences between preoperative and postoperative examinations. Postoperative topographic maps showed a reduction of symmetry index front (0.10 ± 0.64 D). Eyelid ptosis modifies anterior corneal surface inducing refractive errors and modifying corneal astigmatism in patients, thus affecting the quality of vision. The surgical correction of blepharoptosis induces anterior corneal surface modification, restoring corneal symmetry and regular corneal astigmatism. Postoperative corneal topography showed normal corneal contours.

  1. Patching for corneal abrasion.

    Science.gov (United States)

    Lim, Chris H L; Turner, Angus; Lim, Blanche X

    2016-07-26

    Published audits have demonstrated that corneal abrasions are a common presenting eye complaint. Eye patches are often recommended for treating corneal abrasions despite the lack of evidence for their use. This systematic review was conducted to determine the effects of the eye patch when used to treat corneal abrasions. The objective of this review was to assess the effects of patching for corneal abrasion on healing and pain relief. We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (2016, Issue 4), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to May 2016), EMBASE (January 1980 to May 2016), Latin American and Caribbean Health Sciences Literature Database (LILACS) (January 1982 to May 2016), System for Information on Grey Literature in Europe (OpenGrey) (January 1995 to May 2016), the ISRCTN registry (www.isrctn.com/editAdvancedSearch), ClinicalTrials.gov (www.clinicaltrials.gov) and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 9 May 2016. We also searched the reference lists of included studies, unpublished 'grey' literature and conference proceedings and contacted pharmaceutical companies for details of unpublished trials. We included randomised and quasi-randomised controlled trials that compared patching the eye with no patching to treat simple corneal abrasions. Two authors independently assessed the risk of bias and extracted data. Investigators were contacted for further information regarding the quality of trials. The primary outcome was healing at 24, 48 and 72 hours while secondary outcomes included measures of pain, quality of life and adverse effects. We graded the certainty of the evidence using GRADE. We included 12 trials which

  2. Opacity spectra of silicon and carbon in ICF plasmas

    Science.gov (United States)

    Benredjem, D.; Calisti, A.; Ferri, S.; Gilleron, F.; Mondet, G.; Pain, J.-C.

    2017-03-01

    The knowledge of opacity is very important when one investigates the radiative properties of ICF and astrophysical plasmas. Germanium and silicon are good candidates as dopants in the ablator of some ICF schemes (LMJ in France, NIF at Livermore). In this work we calculate the opacity spectra of silicon and carbon mixtures. Two competitive methods were used. The first one is based on a detailed line calculation in which the atomic database is provided by the MCDF code. A lineshape code based on a fast algorithm was then adapted to the calculation of opacity profiles. All major line broadening mechanisms, including Zeeman splitting and Stark effect, are taken into account. This approach provides accurate opacity spectra but becomes rapidly prohibitive when the number of lines is large. To account for systems involving many ionic stages and thousands of lines, a second approach combines detailed line calculations and statistical calculations. This approach necessitates much smaller calculation times than the first one and is then more appropriate for extensive calculations. The monochromatic opacity and the Rosseland and Planck mean opacities are calculated for relevant densities and temperatures.

  3. Computational design of short pulse laser driven iron opacity experiments

    Science.gov (United States)

    Martin, M. E.; London, R. A.; Goluoglu, S.; Whitley, H. D.

    2017-02-01

    The resolution of current disagreements between solar parameters calculated from models and observations would benefit from the experimental validation of theoretical opacity models. Iron's complex ionic structure and large contribution to the opacity in the radiative zone of the sun make iron a good candidate for validation. Short pulse lasers can be used to heat buried layer targets to plasma conditions comparable to the radiative zone of the sun, and the frequency dependent opacity can be inferred from the target's measured x-ray emission. Target and laser parameters must be optimized to reach specific plasma conditions and meet x-ray emission requirements. The HYDRA radiation hydrodynamics code is used to investigate the effects of modifying laser irradiance and target dimensions on the plasma conditions, x-ray emission, and inferred opacity of iron and iron-magnesium buried layer targets. It was determined that plasma conditions are dominantly controlled by the laser energy and the tamper thickness. The accuracy of the inferred opacity is sensitive to tamper emission and optical depth effects. Experiments at conditions relevant to the radiative zone of the sun would investigate the validity of opacity theories important to resolving disagreements between solar parameters calculated from models and observations.

  4. Corneal collagen cross-linking

    Directory of Open Access Journals (Sweden)

    Jankov II Mirko

    2010-01-01

    Full Text Available Corneal collagen cross-linking (CXL with riboflavin and ultraviolet-A (UVA is a new technique of corneal tissue strengthening by using riboflavin as a photosensitizer and UVA to increase the formation of intra- and interfibrillar covalent bonds by photosensitized oxidation. Keratocyte apoptosis in the anterior segment of the corneal stroma all the way down to a depth of about 300 microns has been described and a demarcation line between the treated and untreated cornea has been clearly shown. It is important to ensure that the cytotoxic threshold for the endothelium has not been exceeded by strictly respecting the minimal corneal thickness. Confocal microscopy studies show that repopulation of keratocytes is already visible 1 month after the treatment, reaching its pre-operative quantity and quality in terms of functional morphology within 6 months after the treatment. The major indication for the use of CXL is to inhibit the progression of corneal ectasias, such as keratoconus and pellucid marginal degeneration. CXL may also be effective in the treatment and prophylaxis of iatrogenic keratectasia, resulting from excessively aggressive photoablation. This treatment has also been used to treat infectious corneal ulcers with apparent favorable results. Combination with other treatments, such as intracorneal ring segment implantation, limited topography-guided photoablation and conductive keratoplasty have been used with different levels of success.

  5. Recursive method for opacity expansion at finite temperature%Recursive method for opacity expansion at finite temperature

    Institute of Scientific and Technical Information of China (English)

    刘嘉; 康忠波; 王恩科

    2011-01-01

    Using a reaction operator approach, we derive the multiple-scattering induced gluon number distribution function to all orders in powers of opacity at finite temperature. The detailed balance effect is analyzed by taking into account both gluon emission a

  6. Excimer laser phototherapeutic keratectomy in conjunction with mitomycin C in corneal macular and granular dystrophies

    Directory of Open Access Journals (Sweden)

    Erdem Yuksel

    2016-04-01

    Full Text Available ABSTRACT Purpose: To evaluate the visual outcomes, recurrence patterns, safety, and efficacy of excimer laser phototherapeutic keratectomy (PTK in conjunction with mitomycin C (MMC for corneal macular and granular diystrophies. Methods: The patients were divided into two groups. Group 1 included patients with macular corneal dystrophy (MCD that caused superficial corneal plaque opacities, and Group 2 included patients with granular corneal dystrophy (GCD. Patients in both groups were pre-, peri-, and postoperatively evaluated. The groups were compared in terms of uncorrected visual acuity (VA, best spectacle-corrected VA, presence of mild or significant recurrence, and time of recurrence. Results: Eighteen eyes (nine with MCD and nine with GCD of 18 patients (10 men and eight women were included. PTK was performed for each eye that was included in this study. The mean ablation amount was 117.8 ± 24.4 µm and 83.5 ± 45.7 µm in MCD and GCD, respectively, (p=0.18. The postoperative improvement of the mean VA was similar between the two groups before recurrences (p>0.43 and after recurrences (p>0.71. There were no statistically significant differences in the recurrence rate and the recurrence-free period for any recurrence type. Conclusion: PTK was an effective, safe, and minimally invasive procedure for patients with MCD and GCD. PTK in conjunction with MMC was similarly effective for both groups in terms of recurrence and visual outcomes.

  7. Corneal stromal dystrophies: a clinical pathologic study

    Directory of Open Access Journals (Sweden)

    Elvira Barbosa Abreu

    2012-12-01

    Full Text Available INTRODUCTION: Corneal dystrophy is defined as bilateral and symmetric primary corneal disease, without previous associated ocular inflammation. Corneal dystrophies are classified according to the involved corneal layer in superficial, stromal, and posterior dystrophy. Incidence of each dystrophy varies according to the geographic region studied. PURPOSE: To evaluate the prevalence of stromal corneal dystrophies among corneal buttons specimens obtained by penetrating keratoplasty (PK in an ocular pathology laboratory and to correlate the diagnosis with patient age and gender. METHODS: Corneal button cases of penetrating keratoplasty from January-1996 to May-2009 were retrieved from the archives of The Henry C. Witelson Ophthalmic Pathology Laboratory and Registry, Montreal, Canada. The cases with histopathological diagnosis of stromal corneal dystrophies were stained with special stains (Peroxid acid Schiff, Masson trichrome, Congo red analyzed under polarized light, and alcian blue for classification and correlated with epidemiological information (age at time of PK and gender from patients' file. RESULTS: 1,300 corneal buttons cases with clinical diagnose of corneal dystrophy were retrieved. Stromal corneal dystrophy was found in 40 (3.1% cases. Lattice corneal dystrophy was the most prevalent with 26 cases (65%. Nineteen were female (73.07% and the PK was performed at average age of 59.3 years old. Combined corneal dystrophy was found in 8 (20% cases, 5 (62.5% of them were female and the average age of the penetrating keratoplasty was 54.8 years old. Granular corneal dystrophy was represented by 5 (12.5% cases, and 2 (40% of them were female. Penetrating keratoplasty was performed at average age of 39.5 years old in granular corneal dystrophy cases. Macular corneal dystrophy was present in only 1 (2.5% case, in a 36 years old female. CONCLUSION: Systematic histopathological approach and evaluation, including special stains in all stromal

  8. Evaluation of Factors Limiting Corneal Donation.

    Science.gov (United States)

    Röck, Daniel; Wude, Johanna; Yoeruek, Efdal; Bartz-Schmidt, Karl Ulrich; Röck, Tobias

    2016-11-15

    BACKGROUND This study aimed to investigate factors limiting corneal donation at the University Hospital Tübingen. MATERIAL AND METHODS We retrospectively studied all hospital deaths from January 2012 to December 2015, considering each deceased patient as a potential corneal donor. During this period an ophthalmic resident managed corneal donor procurement on a full-time basis. Various factors limiting corneal donation were examined. RESULTS Among the 3412 deaths, 2937 (86.1%) displayed nonfulfillment of corneal donation. Consent for corneal donation was obtained in 475 cases (13.9%). The mean annual corneal donation rate was 13.9 donors per 100 deaths (range: 11.2-17.8). The leading causes of nonfulfillment of corneal donations were refusal to donate (49.8%, 1698 cases) and medical contraindications (23.6%, 805 cases). After next-of-kin interview of 2173 potential donors (109 potential donors were excluded because of logistical problems), willingness to participate in corneal donation was present in 475 cases (21.9%), whereas in 1698 cases (78.1%) corneal donation was refused. CONCLUSIONS Our study showed refusal to donate is the most important factor limiting corneal donation. It seems that increasing the knowledge of people about corneal donation through public education and media are necessary to address the corneal shortage.

  9. Corneal Biomechanical Findings in Contact Lens Induced Corneal Warpage

    Science.gov (United States)

    Letafatnejad, Mojgan; Beheshtnejad, Amir Hooshang; Ghaffary, Seyed Reza; Hassanpoor, Narges; Yaseri, Mehdi

    2016-01-01

    Purpose. To evaluate the difference in biomechanical properties between contact lens induced corneal warpage and normal and keratoconic eyes. Method. Prospective observational case control study, where 94 eyes of 47 warpage suspicious and 46 eyes of 23 keratoconic patients were included. Warpage suspected cases were followed until a definite diagnosis was made (warpage, normal, or keratoconus). Results. 44 eyes of 22 patients had contact lens related corneal warpage. 46 eyes of 23 people were diagnosed as nonwarpage normal eyes. 46 eyes of 23 known keratoconus patients were included for comparison. The mean age of the participants was 23.8 ± 3.8 years, and 66.2% of the subjects were female. The demographic and refractive data were not different between warpage and normal groups but were different in the keratoconus group. The biomechanical properties (corneal hysteresis or CH and corneal resistance factor or CRF) were different with the highest value in the warpage group followed by normal and keratoconus groups. CRF was 10.08 ± 1.75, 9.23 ± 1.22, and 7.38 ± 2.14 and CH was 10.21 ± 1.57, 9.59 ± 1.21, and 8.69 ± 2.34 in the warpage, normal, and keratoconus groups, respectively. Conclusion. Corneal biomechanics may be different in people who develop contact lens induced warpage. PMID:27688908

  10. Reconstruction of Rabbit Corneal Layer Composed of Corneal Fibroblasts and Corneal Epithelium on the Lyophilized Amniotic Membrane

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Many researchers have employed the cryopreserved amniotic membrane(CAM) and corneal epithelial cells in the treatment of a severely damaged burned cornea, with corneal epithelial cells cultured on an amniotic membrane (AM). The lyophilized amniotic membrane (LAM) has a higher graft take and a longer shelf life; it is easier to store and safer because of gamma irradiation. Two Teflon rings(Ahn's supporter) were made for culturing the cells on the LAM, and were then used to support the LAM. To reconstruct a corneal layer composed of corneal fibroblasts and epithelium, the corneal fibroblasts were first cultivated on the stromal side of LAM for five days, followed by epithelial cells culture on the epithelial side, by using the air-liquid interface culture. The reconstructed corneal layer composed of corneal fibroblasts and corneal epithelial cells has a much healthier basal layer of corneal epithelium than the reconstructed corneal epithelium, which was got by using only corneal epithelial cells, and resembles the epithelium of normal corneas, without the horny layer. Thus, the reconstruction of the corneal layer by using a LAM is considered to be a good in vitro model, not only for its application in toxicological test kits, but also for transplantation in patients with a severely damaged cornea.

  11. Corneal biomechanics: a review.

    Science.gov (United States)

    Piñero, David P; Alcón, Natividad

    2015-03-01

    Biomechanics is often defined as 'mechanics applied to biology'. Due to the variety and complexity of the behaviour of biological structures and materials, biomechanics is better defined as the development, extension and application of mechanics for a better understanding of physiology and physiopathology and consequently for a better diagnosis and treatment of disease and injury. Different methods for the characterisation of corneal biomechanics are reviewed in detail, including those that are currently commercially available (Ocular Response Analyzer and CorVis ST). The clinical applicability of the parameters provided by these devices are discussed, especially in the fields of glaucoma, detection of ectatic disorders and orthokeratology. Likewise, other methods are also reviewed, such as Brillouin microscopy or dynamic optical coherence tomography and others with potential application to clinical practice but not validated for in vivo measurements, such as ultrasonic elastography. Advantages and disadvantages of all these techniques are described. Finally, the concept of biomechanical modelling is revised as well as the requirements for developing biomechanical models, with special emphasis on finite element modelling.

  12. Corneal Decompensation after Selective Laser Trabeculoplasty

    Directory of Open Access Journals (Sweden)

    Ahmet Ozkok

    2014-01-01

    Full Text Available A 64-year-old Caucasian man referred for decreased vision after selective laser trabeculoplasty (SLT. Slit lamp examination revealed diffuse corneal edema. Despite intensive topical treatment including steroids, corneal edema did not resolve; on the contrary, it advanced to bullous keratopathy. Corneal edema after SLT is an exceptionally rare complication and in all of the previous reports edema resolved with medical treatment. To the best of our knowledge, this is the first report presenting persistent corneal edema after SLT.

  13. Progress of research on corneal collagen cross-linking for corneal melting

    Directory of Open Access Journals (Sweden)

    Ke-Ren Xiao

    2016-06-01

    Full Text Available Corneal collagen cross-linking(CXLcould increase the mechanical strength, biological stability and halt ectasia progression due to covalent bond formed by photochemical reaction between ultraviolet-A and emulsion of riboflavin between collagen fibers in corneal stroma. Corneal melting is an autoimmune related noninfectious corneal ulcer. The mechanism of corneal melting, major treatment, the basic fundamental of ultraviolet-A riboflavin induced CXL and the clinical researches status and experiment in CXL were summarized in the study.

  14. Acute corneal hydrops in keratoconus

    Directory of Open Access Journals (Sweden)

    Prafulla K Maharana

    2013-01-01

    Full Text Available Acute corneal hydrops is a condition characterized by stromal edema due to leakage of aqueous through a tear in descemet membrane. The patient presents with sudden onset decrease in vision, photophobia, and pain. Corneal thinning and ectasias combined with trivial trauma to the eye mostly by eye rubbing is considered as the underlying cause. With conservative approach self-resolution takes around 2 to 3 months. Surgical intervention is required in cases of non-resolution of corneal edema to avoid complications and for early visual rehabilitation. Intracameral injection of air or gas such as perflouropropane is the most common surgical procedure done. Recent investigative modality such as anterior segment optical coherence tomography is an extremely useful tool for diagnosis, surgical planning, and postoperative follow up. Resolution of hydrops may improve the contact lens tolerance and visual acuity but most cases require keratoplasty for visual rehabilitation.

  15. Posterior Corneal Surface Stability after Femtosecond Laser-Assisted Keratomileusis

    Directory of Open Access Journals (Sweden)

    Carlo Cagini

    2015-01-01

    Full Text Available The purpose of this study was to evaluate posterior corneal surface variation after femtosecond laser-assisted keratomileusis in patients with myopia and myopic astigmatism. Patients were evaluated by corneal tomography preoperatively and at 1, 6, and 12 months. We analyzed changes in the posterior corneal curvature, posterior corneal elevation, and anterior chamber depth. Moreover, we explored correlation between corneal ablation depth, residual corneal thickness, percentage of ablated corneal tissue, and preoperative corneal thickness. During follow-up, the posterior corneal surface did not have a significant forward corneal shift: no significant linear relationships emerged between the anterior displacement of the posterior corneal surface and corneal ablation depth, residual corneal thickness, or percentage of ablated corneal tissue.

  16. Corneal Molecular and Cellular Biology for the Refractive Surgeon: The Critical Role of the Epithelial Basement Membrane.

    Science.gov (United States)

    Marino, Gustavo K; Santhiago, Marcony R; Torricelli, Andre A M; Santhanam, Abirami; Wilson, Steven E

    2016-02-01

    To provide an overview of the recent advances concerning the corneal molecular and cellular biology processes involved in the wound healing response after excimer laser surface ablation and LASIK surgery. Literature review. The corneal wound healing response is a complex cascade of events that impacts the predictability and stability of keratorefractive surgical procedures such as photorefractive keratectomy and LASIK. The generation and persistence of corneal myofibroblasts (contractile cells with reduced transparency) arise from the interaction of cytokines and growth factors such as transforming growth factor beta and interleukin 1 produced by epithelial and stromal cells in response to the corneal injury. Myofibroblasts, and the opaque extracellular matrix they secrete into the stroma, disturb the precise distribution and spacing of collagen fibers related to corneal transparency and lead to the development of vision-limiting corneal opacity (haze). The intact epithelial basement membrane has a pivotal role as a structure that regulates corneal epithelial-stromal interactions. Thus, defective regeneration of the epithelial basement membrane after surgery, trauma, or infection leads to the development of stromal haze. The apoptotic process following laser stromal ablation, which is proportional to the level of attempted correction, leads to an early decrease in anterior keratocyte density and the diminished contribution of these non-epithelial cells of components such as perlecan and nidogen-2 required for normal regeneration of the epithelial basement membrane. Haze persists until late repair of the defective epithelial basement membrane. Defective regeneration of the epithelial basement membrane has a critical role in determining whether a cornea heals with late haze after photorefractive keratectomy or with scarring at the flap edge in LASIK. Copyright 2016, SLACK Incorporated.

  17. 225 GHz Atmospheric Opacity Measurements from Two Arctic Sites

    CERN Document Server

    Matsushita, S; Martin-Cocher, P; Asada, K; Chen, C -P; Inoue, M; Paine, S; Turner, D; Steinbring, E

    2012-01-01

    We report the latest results of 225 GHz atmospheric opacity measurements from two arctic sites; one on high coastal terrain near the Eureka weather station, on Ellesmere Island, Canada, and the other at the Summit Station near the peak of the Greenland icecap. This is a campaign to search for a site to deploy a new telescope for submillimeter Very Long Baseline Interferometry and THz astronomy in the northern hemisphere. Since 2011, we have obtained 3 months of winter data near Eureka, and about one year of data at the Summit Station. The results indicate that these sites offer a highly transparent atmosphere for observations in submillimeter wavelengths. The Summit Station is particularly excellent, and its zenith opacity at 225 GHz is statistically similar to the Atacama Large Milllimeter/submillimeter Array in Chile. In winter, the opacity at the Summit Station is even comparable to that observed at the South Pole.

  18. Age of old objects constraints on cosmic opacity

    CERN Document Server

    Holanda, R F L; Dantas, M A

    2016-01-01

    In this paper, it is proposed a cosmological model independent method to constrain the cosmic opacity. As an approach never seen before in literature, we use the ages of 32 old passive galaxies distributed over the redshift interval $0.11 < z < 1.84$ and of 9 extremely old globular clusters in M31 galaxy to obtain opacity free luminosity distance. By comparing them to the 580 distance moduli of supernovae from the so-called Union 2.1 compilation we put limits on the cosmic opacity parametrized by $\\tau(z) = \\epsilon z/(1+z)$ (for $\\epsilon =0$ the transparent universe is recovered). Considering the cosmic background radiation constraints on the spatial curvature of the Universe no significant deviation from transparency is verified.

  19. Design And First Use of the NIF Opacity Spectrometer

    Science.gov (United States)

    King, J. A.; Ross, P. W.; Huffman, E. J.; Opachich, Y. P.; Heeter, R. F.; Ahmed, M.; Liedahl, D. A.; Schneider, M. B.; Dodd, E.; Flippo, K. A.; Kline, J. L.; Lopez, F. E.; Archuleta, T. N.; Perry, T. S.

    2016-10-01

    Recent experiments at the Sandia Z facility have raised questions about models used in calculating L-shell opacities of mid-Z elements. A platform is being developed to check these results at the National Ignition Facility (NIF). The NIF experiments require a new X-ray opacity spectrometer (OpSpec) for the iron L-shell X-ray band, spanning photon energies from 540 eV - 2100 eV with a resolving power E/ ΔE >700. The design of the OpSpec and photometric calculations based on expected opacity data are also presented. First use on NIF is expected in September 2016. This work was performed by National Security Technologies, LLC, under Contract No. DE-AC52-06NA25946 with the U.S. Department of Energy. DOE/NV/25946-2891.

  20. Infrared Opacities in Dense Atmospheres of Cool White Dwarf Stars

    CERN Document Server

    Kowalski, Piotr M; Dufour, Patrick

    2016-01-01

    Dense, He-rich atmospheres of cool white dwarfs represent a challenge to the modeling. This is because these atmospheres are constituted of a dense fluid in which strong multi-atomic interactions determine their physics and chemistry. Therefore, the ideal-gas-based description of absorption is no longer adequate, which makes the opacities of these atmospheres difficult to model. This is illustrated with severe problems in fitting the spectra of cool, He-rich stars. Good description of the infrared (IR) opacity is essential for proper assignment of the atmospheric parameters of these stars. Using methods of computational quantum chemistry we simulate the IR absorption of dense He/H media. We found a significant IR absorption from He atoms (He-He-He CIA opacity) and a strong pressure distortion of the H$_2$-He collision-induced absorption (CIA). We discuss the implication of these results for interpretation of the spectra of cool stars.

  1. Fractal Particles: Titan's Thermal Structure and IR Opacity

    Science.gov (United States)

    McKay, C. P.; Rannou, P.; Guez, L.; Young, E. F.; DeVincenzi, Donald (Technical Monitor)

    1998-01-01

    Titan's haze particles are the principle opacity at solar wavelengths. Most past work in modeling these particles has assumed spherical particles. However, observational evidence strongly favors fractal shapes for the haze particles. We consider the implications of fractal particles for the thermal structure and near infrared opacity of Titan's atmosphere. We find that assuming fractal particles with the optical properties based on laboratory tholin material and with a production rate that allows for a match to the geometric albedo results in warmer troposphere and surface temperatures compared to spherical particles. In the near infrared (1-3 microns) the predicted opacity of the fractal particles is up to a factor of two less than for spherical particles. This has implications for the ability of Cassini to image Titan's surface at 1 micron.

  2. Infrared Opacities in Dense Atmospheres of Cool White Dwarf Stars

    Science.gov (United States)

    Kowalski, P. M.; Blouin, S.; Dufour, P.

    2017-03-01

    Dense, He-rich atmospheres of cool white dwarfs represent a challenge to the modeling. This is because these atmospheres are constituted of a dense fluid in which strong multi-atomic interactions determine their physics and chemistry. Therefore, the ideal-gas-based description of absorption is no longer adequate, which makes the opacities of these atmospheres difficult to model. This is illustrated with severe problems in fitting the spectra of cool, He-rich stars. Good description of the infrared (IR) opacity is essential for proper assignment of the atmospheric parameters of these stars. Using methods of computational quantum chemistry we simulate the IR absorption of dense He/H media. We found a significant IR absorption from He atoms (He-He-He CIA opacity) and a strong pressure distortion of the H2-He collision-induced absorption (CIA). We discuss the implication of these results for the interpretation of the spectra of cool stars.

  3. Verification of Opacity and Diagnosability for Pushdown Systems

    Directory of Open Access Journals (Sweden)

    Koichi Kobayashi

    2013-01-01

    Full Text Available In control theory of discrete event systems (DESs, one of the challenging topics is the extension of theory of finite-state DESs to that of infinite-state DESs. In this paper, we discuss verification of opacity and diagnosability for infinite-state DESs modeled by pushdown automata (called here pushdown systems. First, we discuss opacity of pushdown systems and prove that opacity of pushdown systems is in general undecidable. In addition, a decidable class is clarified. Next, in diagnosability, we prove that under a certain assumption, which is different from the assumption in the existing result, diagnosability of pushdown systems is decidable. Furthermore, a necessary condition and a sufficient condition using finite-state approximations are derived. Finally, as one of the applications, we consider data integration using XML (Extensible Markup Language. The obtained result is useful for developing control theory of infinite-state DESs.

  4. Measuring the opacity of stellar interior matter in terrestrial laboratories

    Science.gov (United States)

    Bailey, James

    2015-11-01

    How does energy propagate from the core to the surface of the Sun, where it emerges to warm the Earth? Nearly a century ago Eddington recognized that the attenuation of radiation by stellar matter controls the internal structure of stars like the sun. Opacities for high energy density (HED) matter are challenging to calculate because accurate and complete descriptions of the energy levels, populations, and plasma effects such as continuum lowering and line broadening are needed for partially ionized atoms. This requires approximations, in part because billions of bound-bound and bound-free electronic transitions can contribute to the opacity. Opacity calculations, however, have never been benchmarked against laboratory measurements at stellar interior conditions. Laboratory opacity measurements were limited in the past by the challenges of creating and diagnosing sufficiently large and uniform samples at the extreme conditions found inside stars. In research conducted over more than 10 years, we developed an experimental platform on the Z facility and measured wavelength-resolved iron opacity at electron temperatures Te = 156-195 eV and densities ne = 0.7-4.0 x 1022 cm-3 - conditions very similar to the radiation/convection boundary zone within the Sun. The wavelength-dependent opacity in the 975-1775 eV photon energy range is 30-400% higher than models predict. This raises questions about how well we understand the behavior of atoms in HED plasma. These measurements may also help resolve decade-old discrepancies between solar model predictions and helioseismic observations. This talk will provide an overview of the measurements, investigations of possible errors, and ongoing experiments aimed at testing hypotheses to resolve the model-data discrepancy. Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy under contract DE-AC04-94AL85000.

  5. Correlations between corneal and total wavefront aberrations

    Science.gov (United States)

    Mrochen, Michael; Jankov, Mirko; Bueeler, Michael; Seiler, Theo

    2002-06-01

    Purpose: Corneal topography data expressed as corneal aberrations are frequently used to report corneal laser surgery results. However, the optical image quality at the retina depends on all optical elements of the eye such as the human lens. Thus, the aim of this study was to investigate the correlations between the corneal and total wavefront aberrations and to discuss the importance of corneal aberrations for representing corneal laser surgery results. Methods: Thirty three eyes of 22 myopic subjects were measured with a corneal topography system and a Tschernig-type wavefront analyzer after the pupils were dilated to at least 6 mm in diameter. All measurements were centered with respect to the line of sight. Corneal and total wavefront aberrations were calculated up to the 6th Zernike order in the same reference plane. Results: Statistically significant correlations (p corneal and total wavefront aberrations were found for the astigmatism (C3,C5) and all 3rd Zernike order coefficients such as coma (C7,C8). No statistically significant correlations were found for all 4th to 6th order Zernike coefficients except for the 5th order horizontal coma C18 (p equals 0.003). On average, all Zernike coefficients for the corneal aberrations were found to be larger compared to Zernike coefficients for the total wavefront aberrations. Conclusions: Corneal aberrations are only of limited use for representing the optical quality of the human eye after corneal laser surgery. This is due to the lack of correlation between corneal and total wavefront aberrations in most of the higher order aberrations. Besides this, the data present in this study yield towards an aberration balancing between corneal aberrations and the optical elements within the eye that reduces the aberration from the cornea by a certain degree. Consequently, ideal customized ablations have to take both, corneal and total wavefront aberrations, into consideration.

  6. FTS Measurements of Submillimeter-Wave Atmospheric Opacity at Pampa la Bola: III. Water Vapor, Liquid Water, and 183GHz Water Vapor Line Opacities

    Science.gov (United States)

    Matsushita, Satoki; Matsuo, Hiroshi

    2003-02-01

    Further analysis has been made on the millimeter- and submillimeter-wave (100-1600GHz or 3mm-188 μm) atmospheric opacity data taken with the Fourier Transform Spectrometer (FTS) at Pampa la Bola, 4800 m above the sea level in northern Chile, which is the site of the Atacama Large Millimeter/submillimeter Array (ALMA). Time-sequence plots of millimeter- and submillimeter-wave opacities show similar variations to each other, except for during the periods with liquid water (fog or clouds) in the atmosphere. Using millimeter- and submillimeter-wave opacity correlations under two conditions, which are affected and not affected by liquid water, we succeeded to separate the measured opacity into water vapor and liquid water opacity components. The water vapor opacity shows a good correlation with the 183GHz water vapor line opacity, which is also covered in the measured spectra. On the other hand, the liquid water opacity and the 183GHz line opacity show no correlation. S ince only the water vapor component is expected to affect the phase of interferometers significantly, and the submillimeter-wave opacity is less affected by the liquid water component, it may be possible to use the submillimeter-wave opacity for a phase correction of submillimeter interferometers.

  7. Progress in corneal wound healing.

    Science.gov (United States)

    Ljubimov, Alexander V; Saghizadeh, Mehrnoosh

    2015-11-01

    Corneal wound healing is a complex process involving cell death, migration, proliferation, differentiation, and extracellular matrix remodeling. Many similarities are observed in the healing processes of corneal epithelial, stromal and endothelial cells, as well as cell-specific differences. Corneal epithelial healing largely depends on limbal stem cells and remodeling of the basement membrane. During stromal healing, keratocytes get transformed to motile and contractile myofibroblasts largely due to activation of transforming growth factor-β (TGF-β) system. Endothelial cells heal mostly by migration and spreading, with cell proliferation playing a secondary role. In the last decade, many aspects of wound healing process in different parts of the cornea have been elucidated, and some new therapeutic approaches have emerged. The concept of limbal stem cells received rigorous experimental corroboration, with new markers uncovered and new treatment options including gene and microRNA therapy tested in experimental systems. Transplantation of limbal stem cell-enriched cultures for efficient re-epithelialization in stem cell deficiency and corneal injuries has become reality in clinical setting. Mediators and course of events during stromal healing have been detailed, and new treatment regimens including gene (decorin) and stem cell therapy for excessive healing have been designed. This is a very important advance given the popularity of various refractive surgeries entailing stromal wound healing. Successful surgical ways of replacing the diseased endothelium have been clinically tested, and new approaches to accelerate endothelial healing and suppress endothelial-mesenchymal transformation have been proposed including Rho kinase (ROCK) inhibitor eye drops and gene therapy to activate TGF-β inhibitor SMAD7. Promising new technologies with potential for corneal wound healing manipulation including microRNA, induced pluripotent stem cells to generate corneal

  8. Progress in corneal wound healing

    Science.gov (United States)

    Ljubimov, Alexander V.; Saghizadeh, Mehrnoosh

    2015-01-01

    Corneal wound healing is a complex process involving cell death, migration, proliferation, differentiation, and extracellular matrix remodeling. Many similarities are observed in the healing processes of corneal epithelial, stromal and endothelial cells, as well as cell-specific differences. Corneal epithelial healing largely depends on limbal stem cells and remodeling of the basement membrane. During stromal healing, keratocytes get transformed to motile and contractile myofibroblasts largely due to activation of transforming growth factor-β system. Endothelial cells heal mostly by migration and spreading, with cell proliferation playing a secondary role. In the last decade, many aspects of wound healing process in different parts of the cornea have been elucidated, and some new therapeutic approaches have emerged. The concept of limbal stem cells received rigorous experimental corroboration, with new markers uncovered and new treatment options including gene and microRNA therapy tested in experimental systems. Transplantation of limbal stem cell-enriched cultures for efficient re-epithelialization in stem cell deficiency and corneal injuries has become reality in clinical setting. Mediators and course of events during stromal healing have been detailed, and new treatment regimens including gene (decorin) and stem cell therapy for excessive healing have been designed. This is a very important advance given the popularity of various refractive surgeries entailing stromal wound healing. Successful surgical ways of replacing the diseased endothelium have been clinically tested, and new approaches to accelerate endothelial healing and suppress endothelial-mesenchymal transformation have been proposed including Rho kinase (ROCK) inhibitor eye drops and gene therapy to activate TGF-β inhibitor SMAD7. Promising new technologies with potential for corneal wound healing manipulation including microRNA, induced pluripotent stem cells to generate corneal epithelium, and

  9. [Corneal manifestations in systemic diseases].

    Science.gov (United States)

    Zarranz Ventura, J; De Nova, E; Moreno-Montañés, J

    2008-01-01

    Systemic diseases affecting the cornea have a wide range of manifestations. The detailed study of all pathologies that cause corneal alteration is unapproachable, so we have centered our interest in the most prevalent or characteristic of them. In this paper we have divided these pathologies in sections to facilitate their study. Pulmonar and conective tissue (like colagen, rheumatologic and idiopathic inflamatory diseases), dermatologic, cardiovascular, hematologic, digestive and hepatopancreatic diseases with corneal alteration are described. Endocrine and metabolic diseases, malnutrition and carential states are also studied, as well as some otorhinolaryngologic and genetic diseases that affect the cornea. Finally, a brief report of ocular toxicity induced by drugs is referred.

  10. The Non-local Thermodynamical Equilibrium Effects on Opacity

    Institute of Scientific and Technical Information of China (English)

    WU Ze-Qing; ZHANG Ben-Ai; QIU Yu-Bo

    2001-01-01

    Based on the detailed configuration accounting (DCA) model, a method is developed to include the resonant photoionization and the excitation-autoionization in the non-local thermodynamical equilibrium (NLTE) average atom(AA) model. Using this new model, the mean charge states and the opacity are calculated for NLTE high-Z plasmas and compared with other results. The agreement w ith AA model is poor at low electron density. The present results agree well with those of DCA model within 10%. The calculations show that the NLTE effects on opacity are strong.

  11. Model-independent constraints on the cosmic opacity

    CERN Document Server

    Holanda, R F L; Alcaniz, J S

    2012-01-01

    We use current measurements of the expansion rate $H(z)$ and cosmic background radiation bounds on the spatial curvature of the Universe to impose cosmological model-independent constraints on cosmic opacity. To perform our analyses, we compare opacity-free distance modulus from $H(z)$ data with those from two supernovae Ia compilations, namely, the Union2 and Sloan Digital Sky Survey samples. The influence of different SNe Ia light-curve fitters (SALT2 and MLCS2K2) on the results is also discussed. We find that these fitters present a significant conflict, with the MLCS2K2 method being incompatible with a flat and transparent universe.

  12. Ultra-dense Hot Low Z Line Transition Opacity Simulations

    Science.gov (United States)

    Sauvan, P.; Mínguez, E.; Gil, J. M.; Rodríguez, R.; Rubiano, J. G.; Martel, P.; Angelo, P.; Schott, R.; Philippe, F.; Leboucher-Dalimier, E.; Mancini, R.; Calisti, A.

    2002-12-01

    In this work two atomic physics models (the IDEFIX code using the dicenter model and the code based on parametric potentials ANALOP) have been used to calculate the opacities for bound-bound transitions in hot ultra-dense, low Z plasmas. These simulations are in connection with experiments carried out at LULI during the last two years, focused on bound-bound radiation. In this paper H-like opacities for aluminum and fluorine plasmas have been simulated, using both theoretical models, in a wide range of densities and temperatures higher than 200 eV.

  13. Clinical experiences of photo -therapeutic keratectomy on granular corneal dystrophy(Abstract)%角膜光學切削術治療角膜顆粒狀營養不良的臨床經驗

    Institute of Scientific and Technical Information of China (English)

    金在浩

    2001-01-01

    Six eyes (five patients ) with granular corneal dystrophies underwent photogherapeutic keratectomy (PTK) to ablate corneal opacities with using of two excimer lasers (Summit ExciMed UV 200LA and Visx Star).Follow-up range was from 6 months to 7 years (mean 3 yrs). And 5 patients were improved their corrected vision upto 20/20(20/40-20/20) within a few month after PTK except of one patient who received lamellar keratoplasty on both eyes in 15 yrs ago,underwent again two times PTKs on right eye on 14 yrs and 15 yrs later due to recurrences.There is no doubt that PTK is an advantageous and initial choice of treatment for vision improvement of granular corneal dystrophy instead of corneal grafting. Only one eye among six eyes was only developed to recurrent case.

  14. Corneal Regeneration After Photorefractive Keratectomy: A Review.

    Science.gov (United States)

    Tomás-Juan, Javier; Murueta-Goyena Larrañaga, Ane; Hanneken, Ludger

    2015-01-01

    Photorefractive keratectomy (PRK) remodels corneal stroma to compensate refractive errors. The removal of epithelium and the ablation of stroma provoke the disruption of corneal nerves and a release of several peptides from tears, epithelium, stroma and nerves. A myriad of cytokines, growth factors, and matrix metalloproteases participate in the process of corneal wound healing. Their balance will determine if reepithelization and stromal remodeling are appropriate. The final aim is to achieve corneal transparency for restoring corneal function, and a proper visual quality. Therefore, wound-healing response is critical for a successful refractive surgery. Our goal is to provide an overview into how corneal wounding develops following PRK. We will also review the influence of intraoperative application of mitomycin C, bandage contact lenses, anti-inflammatory and other drugs in preventing corneal haze and post-PRK pain. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  15. Corneal stroma microfibrils

    KAUST Repository

    Hanlon, Samuel D.

    2015-03-01

    Elastic tissue was first described well over a hundred years ago and has since been identified in nearly every part of the body. In this review, we examine elastic tissue in the corneal stroma with some mention of other ocular structures which have been more thoroughly described in the past. True elastic fibers consist of an elastin core surrounded by fibrillin microfibrils. However, the presence of elastin fibers is not a requirement and some elastic tissue is comprised of non-elastin-containing bundles of microfibrils. Fibers containing a higher relative amount of elastin are associated with greater elasticity and those without elastin, with structural support. Recently it has been shown that the microfibrils, not only serve mechanical roles, but are also involved in cell signaling through force transduction and the release of TGF-β. A well characterized example of elastin-free microfibril bundles (EFMBs) is found in the ciliary zonules which suspend the crystalline lens in the eye. Through contraction of the ciliary muscle they exert enough force to reshape the lens and thereby change its focal point. It is believed that the molecules comprising these fibers do not turn-over and yet retain their tensile strength for the life of the animal. The mechanical properties of the cornea (strength, elasticity, resiliency) would suggest that EFMBs are present there as well. However, many authors have reported that, although present during embryonic and early postnatal development, EFMBs are generally not present in adults. Serial-block-face imaging with a scanning electron microscope enabled 3D reconstruction of elements in murine corneas. Among these elements were found fibers that formed an extensive network throughout the cornea. In single sections these fibers appeared as electron dense patches. Transmission electron microscopy provided additional detail of these patches and showed them to be composed of fibrils (~10nm diameter). Immunogold evidence clearly

  16. Corneale crosslinking voor progressieve keratoconus

    NARCIS (Netherlands)

    Wisse, Robert P L; Soeters, Nienke; Godefrooij, Daniel A.; De Koning-Tahzib, Nayyirih G.

    2016-01-01

    Keratoconus is a corneal disease with onset typically occurring during puberty or early adulthood. The cornea progressively thins and acquires a cone-like shape which negatively affects visual acuity. In the early stages, visual acuity can be corrected with glasses or contact lenses. In more

  17. Corneale crosslinking voor progressieve keratoconus

    NARCIS (Netherlands)

    Wisse, Robert P L; Soeters, Nienke; Godefrooij, Daniel A.; De Koning-Tahzib, Nayyirih G.

    2016-01-01

    Keratoconus is a corneal disease with onset typically occurring during puberty or early adulthood. The cornea progressively thins and acquires a cone-like shape which negatively affects visual acuity. In the early stages, visual acuity can be corrected with glasses or contact lenses. In more advance

  18. Terahertz sensing of corneal hydration.

    Science.gov (United States)

    Singh, Rahul S; Tewari, Priyamvada; Bourges, Jean Louis; Hubschman, Jean Pierre; Bennett, David B; Taylor, Zachary D; Lee, H; Brown, Elliott R; Grundfest, Warren S; Culjat, Martin O

    2010-01-01

    An indicator of ocular health is the hydrodyanmics of the cornea. Many corneal disorders deteriorate sight as they upset the normal hydrodynamics of the cornea. The mechanisms include the loss of endothelial pump function of corneal dystophies, swelling and immune response of corneal graft rejection, and inflammation and edema, which accompany trauma, burn, and irritation events. Due to high sensitivity to changes of water content in materials, a reflective terahertz (300 GHz and 3 THz) imaging system could be an ideal tool to measure the hydration level of the cornea. This paper presents the application of THz technology to visualize the hydration content across ex vivo porcine corneas. The corneas, with a thickness variation from 470 - 940 µm, were successfully imaged using a reflective pulsed THz imaging system, with a maximum SNR of 50 dB. To our knowledge, no prior studies have reported on the use of THz in measuring hydration in corneal tissues or other ocular tissues. These preliminary findings indicate that THz can be used to accurately sense hydration levels in the cornea using a pulsed, reflective THz imaging system.

  19. Clinical Observation of Transepithelial Corneal Collagen Cross-linking by Iontophoresis of Riboflavin in Treatment of Keratoconus

    Institute of Scientific and Technical Information of China (English)

    Na Li; Zhengjun Fan; Xiujun Peng; Xu Pang; Chunyu Tian

    2014-01-01

    Purpose: To evaluate the efficacy and safety of transepithelial collagen cross-linking by iontophoretic delivery of riboflavin in treatment of progressive keratoconus.Methods:.Eleven patients (15 eyes) with progressive kerato-conus were enrolled. After 0.1% riboflavin-distilled water so-lution was deliveried via transepithelial iontophpresis for 5 min with 1 mA current, and ultraviolet radiation (370 nm,.3 mW /cm2) was performed at a 1.5 cm distance for 30 min. The fol-low up were 6 months in all eyes. The uncorrected visual acu-ity, corrected visual acuity,endothelial cell counting, corneal thickness,.intraocular pressure, corneal curvature, corneal to-pography,.OCT and corneal opacity before and 6-month after surgery were analyzed.Results: At 6 month postoperatively, mean uncorrected visual acuity and corrected visual acuity changed from 0.36 to 0.30 and from 0.42 to 0.57 without statistical significance..The mean value of each index of corneal curvature declined with-out statistical significance.Kmax value dereased from 60.91 to 59.91, and the astigmatism declined from 3.86 to 3.19. Cen-tral corneal thickness decreased from 460.93 μm to 455.40μm,.and thinnest corneal thickness declined from 450.87 μm to 440.60 μm with no statistical significance..Intraocular pres-sure was significantly elevated from 10.85 mmHg to 12.62 mmHg. Endothelial cell count did not change significantly. No corneal haze occurred. Mean depth of corneal demarcation line was 288.46 μm at 1 month postoperatively..Conclusion:.Transepithelial corneal collagen cross-linking by iontophoresis is effective and safe in the treatment of progres-sive keratoconus, and yields stable clinical outcomes during 6-month follow up..However,.long-term follow up is urgently required. (Eye Science 2014; 29:160-164)

  20. FIRST NEW SOLAR MODELS WITH OPAS OPACITY TABLES

    Energy Technology Data Exchange (ETDEWEB)

    Le Pennec, M.; Turck-Chièze, S.; Salmon, S. [CEA/IRFU/Service d’Astrophysique, CE Saclay, F-91191 Gif sur Yvette (France); Blancard, C.; Cossé, P.; Faussurier, G.; Mondet, G. [CEA, DAM, DIF, F-91297 Arpajon (France)

    2015-11-10

    Stellar seismology appears more and more as a powerful tool for a better determination of the fundamental properties of solar-type stars. However, the particular case of the Sun is still challenging. For about a decade now, the helioseismic sound-speed determination has continued to disagree with the standard solar model (SSM) prediction, questioning the reliability of this model. One of the sources of uncertainty could be in the treatment of the transport of radiation from the solar core to the surface. In this Letter, we use the new OPAS opacity tables, recently available for solar modeling, to address this issue. We discuss first the peculiarities of these tables, then we quantify their impact on the solar sound-speed and density profiles using the reduced OPAS tables taken on the grids of the OPAL ones. We use the two evolution codes, Modules for Experiments in Stellar Astrophysics and Code Liégeois d’Evolution Stellaire, that led to similar conclusions in the solar radiative zone. In comparison to commonly used OPAL opacity tables, the new solar models are computed for the most recent photospheric composition with OPAS tables and present improvements to the location of the base of the convective zone and to the description of the solar radiative zone in comparison to the helioseismic observations, even if the differences in the Rosseland mean opacity do not exceed 6%. We finally carry out a comparison to a solar model computed with the OP opacity tables.

  1. Design Parameter Studies of Emission-Based Iron Opacity Measurements

    Science.gov (United States)

    Martin, Madison E.; London, Richard A.; Goluoglu, Sedat; Whitley, Heather D.

    2016-10-01

    Opacity is a critical parameter in the transport of radiation in systems such as inertial confinement fusion capsules and stars. The resolution of current disagreements between solar models and helioseismological observations would benefit from experimental validation of theoretical opacity models. Short pulse lasers can be used to heat targets to higher temperatures and densities than long pulse lasers and pulsed power machines, thus potentially enabling access to x-ray emission spectra at conditions relevant to solar models. The radiation-hydrodynamic code HYDRA is used to investigate the effects of modifying laser energy, laser pulse length, and target dimensions on the plasma conditions, x-ray emission, and inferred opacity of a buried layer iron target. The accuracy of the opacity inference is sensitive to tamper emission and optical depth effects. An example design that reaches temperatures and densities relevant to the radiative zone of the sun while reducing optical depth and tamper emission effects will be discussed. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344. Lawrence Livermore National Security, LLC.

  2. 40 CFR 75.14 - Specific provisions for monitoring opacity.

    Science.gov (United States)

    2010-07-01

    ... calendar year. (d) Diesel-fired units and dual-fuel reciprocating engine units. The owner or operator of an affected diesel-fired unit or a dual-fuel reciprocating engine unit is exempt from the opacity monitoring... unit by changing its fuel mix, the owner or operator shall install, operate, and certify a continuous...

  3. The fog of change : opacity and asperity in organizations.

    OpenAIRE

    Hannan, M.T.; Pólos, L.; Carroll, G.R.

    2003-01-01

    Initial architectural change in organizations often induces other subsequent changes, generating lengthy cascades of changes in subordinate units. This article extends a formal model of cascading organizational change by examining the implications for organizational change of the limited foresight of those who initiate such change about unit interconnections (structural opacity) and the normative restrictiveness imposed on architectural features by organizational culture (cultural asperity). ...

  4. Management of corneal bee sting

    Directory of Open Access Journals (Sweden)

    Razmjoo H

    2011-12-01

    Full Text Available Hassan Razmjoo1,2, Mohammad-Ali Abtahi1,2,4, Peyman Roomizadeh1,3, Zahra Mohammadi1,2, Seyed-Hossein Abtahi1,3,41Medical School, Isfahan University of Medical Sciences (IUMS; 2Ophthalmology Ward, Feiz Hospital, IUMS; 3Isfahan Medical Students Research Center (IMSRC, IUMS; 4Isfahan Ophthalmology Research Center (IORC, Feiz Hospital, IUMS, Isfahan, IranAbstract: Corneal bee sting is an uncommon environmental eye injury that can result in various ocular complications with an etiology of penetrating, immunologic, and toxic effects of the stinger and its injected venom. In this study we present our experience in the management of a middle-aged male with a right-sided deep corneal bee sting. On arrival, the patient was complaining of severe pain, blurry vision with acuity of 160/200, and tearing, which he had experienced soon after the injury. Firstly, we administered conventional drugs for eye injuries, including topical antibiotic, corticosteroid, and cycloplegic agents. After 2 days, corneal stromal infiltration and edema developed around the site of the sting, and visual acuity decreased to 100/200. These conditions led us to remove the stinger surgically. Within 25 days of follow-up, the corneal infiltration decreased gradually, and visual acuity improved to 180/200. We suggest a two-stage management approach for cases of corneal sting. For the first stage, if the stinger is readily accessible or primary dramatic reactions, including infiltration, especially on the visual axis, exist, manual or surgical removal would be indicated. Otherwise, we recommend conventional treatments for eye injuries. Given this situation, patients should be closely monitored for detection of any worsening. If the condition does not resolve or even deteriorates, for the second stage, surgical removal of the stinger under local or generalized anesthesia is indicated.Keywords: bee sting, stinger, cornea, removal, management, surgery

  5. FTS measurements of submillimeter-wave opacity at Pampa la Bola

    Science.gov (United States)

    Matsuo, Hiroshi; Sakamoto, Akihiro; Matsushita, Satoki

    1998-07-01

    The first measurement of submillimeter-wave atmospheric opacity spectra at the Pampa la Bola site (Northern Chile, Atacama 4800 m altitude) has been performed during the winter season using a Fourier transform spectrometer (FTS). Atmospheric emission spectra, as a function of airmass, were measured under various weather conditions. Atmospheric opacity was evaluated from sky temperature at zenith as well as from tipping measurements, which are independent measure but give consistent results. The FTS opacity measurements also show good match with 220 GHz radiometer measurements. Correlations between millimeter-wave and submillimeter-wave opacities get worse when 220 GHz opacity is larger than 0.1. Deviations from the opacity correlation at each frequency show good correlations themselves but have different relative variations at each frequency. This indicates that atmospheric transparency cannot be characterized only by millimeter-wave opacity buy requires simultaneous opacity measurements at millimeter and submillimeter-wavelengths.

  6. Turning the tide of corneal blindness.

    Science.gov (United States)

    Oliva, Matthew S; Schottman, Tim; Gulati, Manoj

    2012-01-01

    Corneal diseases represent the second leading cause of blindness in most developing world countries. Worldwide, major investments in public health infrastructure and primary eye care services have built a strong foundation for preventing future corneal blindness. However, there are an estimated 4.9 million bilaterally corneal blind persons worldwide who could potentially have their sight restored through corneal transplantation. Traditionally, barriers to increased corneal transplantation have been daunting, with limited tissue availability and lack of trained corneal surgeons making widespread keratoplasty services cost prohibitive and logistically unfeasible. The ascendancy of cataract surgical rates and more robust eye care infrastructure of several Asian and African countries now provide a solid base from which to dramatically expand corneal transplantation rates. India emerges as a clear global priority as it has the world's largest corneal blind population and strong infrastructural readiness to rapidly scale its keratoplasty numbers. Technological modernization of the eye bank infrastructure must follow suit. Two key factors are the development of professional eye bank managers and the establishment of Hospital Cornea Recovery Programs. Recent adaptation of these modern eye banking models in India have led to corresponding high growth rates in the procurement of transplantable tissues, improved utilization rates, operating efficiency realization, and increased financial sustainability. The widespread adaptation of lamellar keratoplasty techniques also holds promise to improve corneal transplant success rates. The global ophthalmic community is now poised to scale up widespread access to corneal transplantation to meet the needs of the millions who are currently blind.

  7. Turning the tide of corneal blindness

    Directory of Open Access Journals (Sweden)

    Matthew S Oliva

    2012-01-01

    Full Text Available Corneal diseases represent the second leading cause of blindness in most developing world countries. Worldwide, major investments in public health infrastructure and primary eye care services have built a strong foundation for preventing future corneal blindness. However, there are an estimated 4.9 million bilaterally corneal blind persons worldwide who could potentially have their sight restored through corneal transplantation. Traditionally, barriers to increased corneal transplantation have been daunting, with limited tissue availability and lack of trained corneal surgeons making widespread keratoplasty services cost prohibitive and logistically unfeasible. The ascendancy of cataract surgical rates and more robust eye care infrastructure of several Asian and African countries now provide a solid base from which to dramatically expand corneal transplantation rates. India emerges as a clear global priority as it has the world′s largest corneal blind population and strong infrastructural readiness to rapidly scale its keratoplasty numbers. Technological modernization of the eye bank infrastructure must follow suit. Two key factors are the development of professional eye bank managers and the establishment of Hospital Cornea Recovery Programs. Recent adaptation of these modern eye banking models in India have led to corresponding high growth rates in the procurement of transplantable tissues, improved utilization rates, operating efficiency realization, and increased financial sustainability. The widespread adaptation of lamellar keratoplasty techniques also holds promise to improve corneal transplant success rates. The global ophthalmic community is now poised to scale up widespread access to corneal transplantation to meet the needs of the millions who are currently blind.

  8. Clinical applications of corneal confocal microscopy

    Directory of Open Access Journals (Sweden)

    Mitra Tavakoli

    2008-06-01

    Full Text Available Mitra Tavakoli1, Parwez Hossain2, Rayaz A Malik11Division of Cardiovascular Medicine, University of Manchester and Manchester Royal Infirmary, Manchester, UK; 2University of Southampton, Southampton Eye Unit, Southampton General Hospital, Southampton, UKAbstract: Corneal confocal microscopy is a novel clinical technique for the study of corneal cellular structure. It provides images which are comparable to in-vitro histochemical techniques delineating corneal epithelium, Bowman’s layer, stroma, Descemet’s membrane and the corneal endothelium. Because, corneal confocal microscopy is a non invasive technique for in vivo imaging of the living cornea it has huge clinical potential to investigate numerous corneal diseases. Thus far it has been used in the detection and management of pathologic and infectious conditions, corneal dystrophies and ecstasies, monitoring contact lens induced corneal changes and for pre and post surgical evaluation (PRK, LASIK and LASEK, flap evaluations and Radial Keratotomy, and penetrating keratoplasty. Most recently it has been used as a surrogate for peripheral nerve damage in a variety of peripheral neuropathies and may have potential in acting as a surrogate marker for endothelial abnormalities.Keywords: corneal confocal microscopy, cornea, infective keratitis, corneal dystrophy, neuropathy

  9. 77 FR 13997 - Quality Assurance Requirements for Continuous Opacity Monitoring Systems at Stationary Sources

    Science.gov (United States)

    2012-03-08

    ... AGENCY 40 CFR Part 60 RIN 2060-AH23 Quality Assurance Requirements for Continuous Opacity Monitoring... rule titled, ``Quality Assurance Requirements for Continuous Opacity Monitoring Systems at Stationary....regulations.gov or in hard copy at the Procedure 3--Quality Assurance Requirements for Continuous Opacity...

  10. Differential expression of epithelial basement membrane components nidogens and perlecan in corneal stromal cells in vitro.

    Science.gov (United States)

    Santhanam, Abirami; Torricelli, Andre A M; Wu, Jiahui; Marino, Gustavo K; Wilson, Steven E

    2015-01-01

    The purpose of this study was to examine the expression of corneal epithelial basement membrane (EBM) components in different corneal stromal cell types. In vitro model systems were used to explore the expression of EBM components nidogen-1, nidogen-2, and perlecan that are the primary components in the lamina lucida and the lamina densa that defectively regenerate in corneas with stromal opacity after in -9.0 D photorefractive keratectomy (PRK). Primary rabbit corneal stromal cells were cultured using varying serum concentrations and exogenous growth factors, including fibroblast growth factor (FGF)-2 and transforming growth factor (TGF)-β1, to optimize the growth of each cell type of interest. The expression of the keratocyte-specific marker keratocan and the myofibroblast-specific marker α-smooth muscle actin (α-SMA) were analyzed with real-time PCR, western blot, and immunocytochemical staining to evaluate the specificity of the cell types and select optimal conditions (high keratocan and low α-SMA for keratocytes; low keratocan and high α-SMA for myofibroblasts; low keratocan and low α-SMA for corneal fibroblasts). The expression of the EBM components nidogen-1, nidogen-2, and perlecan was evaluated in each corneal cell type using real-time PCR, immunostaining, and western blotting. In agreement with previous studies, serum-free DMEM was found to be optimal for keratocytes, DMEM with 10% serum and 40 ng/ml FGF-2 yielded the best marker profile for corneal fibroblasts, and DMEM with 1% serum and 2 ng/ml TGF-β1 was found to be optimal for myofibroblasts. Nidogen-1 and nidogen-2 mRNAs were highly expressed in keratocytes, whereas perlecan was highly expressed in myofibroblasts. In keratocytes, nidogen-2 and perlecan proteins were expressed predominantly in intracellular compartments, whereas in myofibroblasts expression of both EBM components was observed diffusely throughout the cell. Although the perlecan mRNA levels were high in the myofibroblasts, the

  11. Visual outcome after corneal transplantation for corneal perforation and iris prolapse in 37 horses

    DEFF Research Database (Denmark)

    Henriksen, Michala de Linde; Plummer, C. E.; Mangan, B.;

    2012-01-01

    We wanted to investigate the visual outcome of horses presented with iris prolapse and treated with corneal transplantation.......We wanted to investigate the visual outcome of horses presented with iris prolapse and treated with corneal transplantation....

  12. Determination of corneal image-forming properties from corneal topography.

    Science.gov (United States)

    Maloney, R K; Bogan, S J; Waring, G O

    1993-01-01

    Keratometry provides useful information about the cornea's image-forming properties, such as corneal astigmatism, but is inaccurate on irregular corneas. Quantitative corneal topographic information is now obtainable on irregular corneas, but is difficult for the clinician to interpret. We developed a method to determine the spherical power, astigmatism, and topographic irregularity of a cornea by finding the best-fit spherocylinder that was closest to its measured topography. Keratometric measurements and two videokeratographs were gathered prospectively on 262 normal and abnormal corneas. The best-fit measurements of spherical power, astigmatism, and topographic irregularity were reproducible with one standard deviation of 0.75 diopter or better; agreement with keratometric measurements in normal eyes was good (0.60 diopter or better). Topographic irregularity averaged 0.1 diopter on precision spheres, 0.4 diopter on 146 normal eyes, 0.8 diopter on 29 eyes after radial keratotomy, 2.0 diopters on 58 eyes after penetrating keratoplasty, and 3.0 diopters on 29 eyes with advanced keratoconus. We conclude the following: basic corneal image-forming properties can be measured from videokeratographs; the properties can be determined, by our methods, on irregular corneas in which keratometry is unreliable; and topographic irregularity provides a measure of irregular astigmatism.

  13. Genetics Home Reference: lattice corneal dystrophy type I

    Science.gov (United States)

    ... corneal dystrophy type I lattice corneal dystrophy type I Enable Javascript to view the expand/collapse boxes. ... All Close All Description Lattice corneal dystrophy type I is an eye disorder that affects the clear, ...

  14. Immunoglobulins in granular corneal dystrophy Groenouw type I

    DEFF Research Database (Denmark)

    Møller, H U; Bojsen-Møller, M; Schrøder, H D

    1993-01-01

    Three patients with granular corneal dystrophy Groenouw type I underwent corneal grafting, and cryostat sections of the corneal buttons were examined immunohistochemically for immunoglobulins. Positive results were obtained for IgG, Kappa-, and Lambda chains with immunofluorescence technique...

  15. Polar Value Analysis of Corneal Astigmatism in Intrastromal Corneal Ring Segment Implantation

    OpenAIRE

    Chang Rae Rho; Min-Ji Kim; Choun-Ki Joo

    2016-01-01

    Purpose. To evaluate surgically induced astigmatism (SIA) and the average corneal power change in symmetric intrastromal corneal ring segment (ICRS) implantation. Methods. The study included 34 eyes of 34 keratoconus patients who underwent symmetric Intacs SK ICRS implantation. The corneal pocket incision meridian was the preoperative steep meridian. Corneal power data were obtained before and 3 months after Intacs SK ICRS implantation using scanning-slit topography. Polar value analysis was ...

  16. EVIDENCE FOR ENVIRONMENTAL CHANGES IN THE SUBMILLIMETER DUST OPACITY

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Peter G.; Roy, Arabindo; Miville-Deschenes, Marc-Antoine [Canadian Institute for Theoretical Astrophysics, University of Toronto, 60 St. George Street, Toronto, ON M5S 3H8 (Canada); Bontemps, Sylvain [Observatoire de Bordeaux, BP 89, F-33270 Floirac (France); Ade, Peter A. R.; Griffin, Matthew; Hargrave, Peter C.; Mauskopf, Philip [Department of Physics and Astronomy, Cardiff University, 5 The Parade, Cardiff, CF24 3AA (United Kingdom); Bock, James J. [Jet Propulsion Laboratory, Pasadena, CA 91109-8099 (United States); Chapin, Edward L.; Halpern, Mark; Marsden, Gaelen [Department of Physics and Astronomy, University of British Columbia, 6224 Agricultural Road, Vancouver, BC V6T 1Z1 (Canada); Devlin, Mark J.; Dicker, Simon R.; Klein, Jeff [Department of Physics and Astronomy, University of Pennsylvania, 209 South 33rd Street, Philadelphia, PA 19104 (United States); Gundersen, Joshua O. [Department of Physics, University of Miami, 1320 Campo Sano Drive, Carol Gables, FL 33146 (United States); Hughes, David H. [Instituto Nacional de Astrofisica Optica y Electronica (INAOE), Aptdo. Postal 51 y 72000 Puebla (Mexico); Netterfield, Calvin B. [Department of Astronomy and Astrophysics, University of Toronto, 50 St. George Street, Toronto, ON M5S 3H4 (Canada); Olmi, Luca [INAF, Osservatorio Astrofisico di Arcetri, Largo E. Fermi 5, I-50125 (Italy); Patanchon, Guillaume [Laboratoire APC, 10, rue Alice Domon et Leonie Duquet F-75205 Paris (France); and others

    2012-05-20

    The submillimeter opacity of dust in the diffuse interstellar medium (ISM) in the Galactic plane has been quantified using a pixel-by-pixel correlation of images of continuum emission with a proxy for column density. We used multi-wavelength continuum data: three Balloon-borne Large Aperture Submillimeter Telescope bands at 250, 350, and 500 {mu}m and one IRAS band at 100 {mu}m. The proxy is the near-infrared color excess, E(J - K{sub s}), obtained from the Two Micron All Sky Survey. Based on observations of stars, we show how well this color excess is correlated with the total hydrogen column density for regions of moderate extinction. The ratio of emission to column density, the emissivity, is then known from the correlations, as a function of frequency. The spectral distribution of this emissivity can be fit by a modified blackbody, whence the characteristic dust temperature T and the desired opacity {sigma}{sub e}(1200) at 1200 GHz or 250 {mu}m can be obtained. We have analyzed 14 regions near the Galactic plane toward the Vela molecular cloud, mostly selected to avoid regions of high column density (N{sub H} > 10{sup 22} cm{sup -2}) and small enough to ensure a uniform dust temperature. We find {sigma}{sub e}(1200) is typically (2-4) Multiplication-Sign 10{sup -25} cm{sup 2} H{sup -1} and thus about 2-4 times larger than the average value in the local high Galactic latitude diffuse atomic ISM. This is strong evidence for grain evolution. There is a range in total power per H nucleon absorbed (and re-radiated) by the dust, reflecting changes in the strength of the interstellar radiation field and/or the dust absorption opacity. These changes in emission opacity and power affect the equilibrium T, which is typically 15 K, colder than at high latitudes. Our analysis extends, to higher opacity and lower temperature, the trend of increasing {sigma}{sub e}(1200) with decreasing T that was found at high latitudes. The recognition of changes in the emission opacity

  17. Obtaining corneal tissue for keratoplasty.

    Science.gov (United States)

    Navarro Martínez-Cantullera, A; Calatayud Pinuaga, M

    2016-10-01

    Cornea transplant is the most common tissue transplant in the world. In Spain, tissue donation activities depend upon transplant coordinator activities and the well-known Spanish model for organ and tissue donation. Tissue donor detection system and tissue donor evaluation is performed mainly by transplant coordinators using the Spanish model on donation. The evaluation of a potential tissue donor from detection until recovery is based on an exhaustive review of the medical and social history, physical examination, family interview to determine will of the deceased, and a laboratory screening test. Corneal acceptance criteria for transplantation have a wider spectrum than other tissues, as donors with active malignancies and infections are accepted for kearatoplasty in most tissue banks. Corneal evaluation during the whole process is performed to ensure the safety of the donor and the recipient, as well as an effective transplant. Last step before processing, corneal recovery, must be performed under standard operating procedures and in a correct environment. Copyright © 2016 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  18. Nuclear reaction rates and opacity in massive star evolution calculations

    Energy Technology Data Exchange (ETDEWEB)

    Bahena, D [Astronomical Institute of the Academy of Sciences, BocnI II 1401, 14131 Praha 4 (Czech Republic); Klapp, J [Instituto Nacional de Investigaciones Nucleares, Km. 36.5 Carr. Mexico-Toluca, 52750 Edo. de Mexico (Mexico); Dehnen, H, E-mail: jaime.klapp@inin.gob.m [Universitaet Konstanz, Fachbereich Physik, Fach M568, D-78457 Konstanz (Germany)

    2010-07-01

    Nuclear reaction rates and opacity are important parameters in stellar evolution. The input physics in a stellar evolution code determines the main theoretical characteristics of the stellar structure, evolution and nucleosynthesis of a star. For different input physics, in this work we calculate stellar evolution models of very massive first stars during the hydrogen and helium burning phases. We have considered 100 and 200M{sub s}un galactic and pregalactic stars with metallicity Z = 10{sup -6} and 10{sup 9}, respectively. The results show important differences from old to new formulations for the opacity and nuclear reaction rates, in particular the evolutionary tracks are significantly affected, that indicates the importance of using up to date and reliable input physics. The triple alpha reaction activates sooner for pregalactic than for galactic stars.

  19. Towards a new model of OPAC. From information to knowledge.

    Directory of Open Access Journals (Sweden)

    Antonella Iacono

    2013-07-01

    Full Text Available Il contributo analizza l’evoluzione dei cataloghi elettronici delle biblioteche alla luce delle nuove tecnologie del Web semantico e dei linked data. La trattazione è suddivisa in due parti distinte. In questa prima parte muovendo da un’analisi critica del modello funzionale degli ‘OPAC di nuova generazione’ e discovery tools si propone la necessità di una revisione del paradigma corrente di sviluppo che accogliendo le teorie dell’information behavior possa fondarsi sull'utente, sui suoi bisogni informativi, i suoi comportamenti e sull'analisi delle componenti che entrano in gioco nel processo di ricerca dell'informazione.Nella seconda parte, di prossima pubblicazione si è esplorerà la possibilità che i linked data possano essere la tecnologia più appropriata per la costruzione di nuovi OPAC basati sulla produzione di conoscenza all’interno del processo informativo. 

  20. Model-independent constraints on the cosmic opacity

    Energy Technology Data Exchange (ETDEWEB)

    Holanda, R.F.L. [Departamento de Física, Universidade Estadual da Paraíba, 58429-500, Campina Grande - PB (Brazil); Carvalho, J.C.; Alcaniz, J.S., E-mail: holanda@uepb.edu.br, E-mail: carvalho@dfte.ufrn.br, E-mail: alcaniz@on.br [Departamento de Astronomia, Observatório Nacional, 20921-400, Rio de Janeiro - RJ (Brazil)

    2013-04-01

    We use current measurements of the expansion rate H(z) and cosmic background radiation bounds on the spatial curvature of the Universe to impose cosmological model-independent constraints on cosmic opacity. To perform our analyses, we compare opacity-free distance modulus from H(z) data with those from two type Ia supernovae compilations, namely, the Union2.1 plus the most distant spectroscopically confirmed SNe Ia (SCP-0401 at z = 1.713) and two Sloan Digital Sky Survey (SDSS) subsamples. We find that a completely transparent universe is in full agreement with the Union 2.1 + SNe Ia SCP-0401 sample. For the SDSS compilations, such universe is compatible with observations at < 1.5σ level regardless the SNe Ia light-curve fitting used.

  1. Design of Initial Opacity Platform at the National Ignition Facility

    Science.gov (United States)

    Heeter, R. F.; Ahmed, M. F.; Ayers, S. L.; Emig, J. A.; Iglesias, C. A.; Liedahl, D. A.; Schneider, M. B.; Wilson, B. G.; Huffman, E. J.; King, J. A.; Opachich, Y. P.; Ross, P. W.; Bailey, J. E.; Rochau, G. A.; Craxton, R. S.; Garcia, E. M.; McKenty, P. W.; Zhang, R.; Cardenas, T.; Devolder, B. G.; Dodd, E. S.; Kline, J. L.; Sherrill, M. E.; Perry, T. S.

    2016-10-01

    The absorption and re-emission of x-rays by partly stripped ions plays a critical role in stars and in many laboratory plasmas. A NIF Opacity Platform has been designed to resolve a persistent disagreement between theory and experiments on the Sandia Z facility, studying iron in conditions closely related to the solar radiation-convection transition boundary. A laser heated hohlraum ``oven'' will produce iron plasmas at temperatures >150 eV and electron densities >=7x1021/cm3, and be probed with continuum X-rays from a capsule implosion backlighter source. The resulting X-ray transmission spectra will be recorded on a specially designed Opacity Spectrometer. This work was performed under the auspices of the U.S. Department of Energy by LLNL under Contract DE-AC52-07NA27344.

  2. Equation of state and opacities for warm dense matter

    Directory of Open Access Journals (Sweden)

    Cotelo Manuel

    2013-11-01

    Full Text Available This work presents recent developments in the calculation of opacity and equation of state tables suitable for including in the radiation hydrodynamic code ARWEN [1] to study processes like ICF or X-ray secondary sources. For these calculations we use the code bigbart to compute opacities in LTE conditions, with self-consistent data generated with the Flexible Atomic Code (FAC [2]. Non-LTE effects are approximately taken into account by means of the new RADIOM model developed in [3], which makes use of existing LTE data tables. We use the screened-hydrogenic model [4] to derive the Equation of State (EOS using the population and energy of each level.

  3. Skewed gas flow technology offers antidote to opacity derates

    Energy Technology Data Exchange (ETDEWEB)

    Boyd, M. [ATCO Power AB (Canada). Battle River Generating Station

    2001-06-01

    Deratings due to opacity problems at the Battle River Generating Station in Alberta, Canada led ATCO Power to evaluate and install skewed gas flow technology (SGFT) in one-half of the Unit 5 twin-casing electrostatic precipitator during the August 2000 outage. Preliminary operating results show that the modified casing produces opacity readings at the outlet 40% lower than those seen at the outlet of the unmodified casing. The dust loading tests indicate a 27.5% improvement in collector efficiency. This article includes a technical review and evaluation of Battle River's SGFT installation, as well as the rationale used to provide the initial economic justification. 3 figs., 1 tab., 1 photo.

  4. Opacity calculations for Non-Local-Thermodynamic-Equilibrium plasmas

    Institute of Scientific and Technical Information of China (English)

    PANG Jin-qiao; WU Ze-qing; YAN Jun; HAN Guo-xing

    2004-01-01

    In this paper, we presented a method to calculate the spectral-resolved opacity for Non-Local-Thermodynamic-Equilibrium (non-LTE) plasmas. By solving the rate equations, we get the population. In the rate equations, configuration-averaged rate coefficients are used and the cross sections are calculated based on the first-perturbation theory. Using the detailed configuration accounting with the term structures treated by the unresolved transition array model, we calculated the spectral-resolved opacity of Al plasmas. The results are compared with those of other theoretical models. From the comparison, we can see that the present results fit well with other models for low-Z plasmas. For high-Z plasmas, we will give detailed discussion in the future.

  5. FTS Measurements of Submillimeter-Wave Atmospheric Opacity at Pampa la Bola

    Science.gov (United States)

    Matsuo, Hiroshi; Sakamoto, Akihiro; Matsushita, Satoki

    1998-06-01

    The first measurements of submillimeter-wave atmospheric opacity spectra at the Pampa la Bola site (Northern Chile, Atacama, 4800 m altitude) have been performed during the winter season using a Fourier transform spectrometer (FTS). Atmospheric emission spectra, as a function of airmass, were measured under various weather conditions. Atmospheric opacity was evaluated from sky temperature at the zenith as well as from tipping measurements, which are independent measures but give consistent results. Correlation diagrams between 220 GHz and 345 GHz, 410 GHz, 492 GHz, 675 GHz, 691 GHz, 809 GHz, 875 GHz are shown. Correlations between millimeter-wave and submillimeter-wave opacities get worse when 220 GHz opacity is larger than 0.1. Deviations from the opacity correlation at each frequency show good correlations themselves, but have different relative variations at each frequency. This indicates that atmospheric transparency cannot be characterized only by millimeter-wave opacity, but requires simultaneous opacity measurements at millimeter and submillimeter-wavelengths.

  6. A native-like corneal construct using donor corneal stroma for tissue engineering.

    Directory of Open Access Journals (Sweden)

    Jing Lin

    Full Text Available Tissue engineering holds great promise for corneal transplantation to treat blinding diseases. This study was to explore the use of natural corneal stroma as an optimal substrate to construct a native like corneal equivalent. Human corneal epithelium was cultivated from donor limbal explants on corneal stromal discs prepared by FDA approved Horizon Epikeratome system. The morphology, phenotype, regenerative capacity and transplantation potential were evaluated by hematoxylin eosin and immunofluorescent staining, a wound healing model, and the xeno-transplantation of the corneal constructs to nude mice. An optically transparent and stratified epithelium was rapidly generated on donor corneal stromal substrate and displayed native-like morphology and structure. The cells were polygonal in the basal layer and became flattened in superficial layers. The epithelium displayed a phenotype similar to human corneal epithelium in vivo. The differentiation markers, keratin 3, involucrin and connexin 43, were expressed in full or superficial layers. Interestingly, certain basal cells were immunopositive to antibodies against limbal stem/progenitor cell markers ABCG2 and p63, which are usually negative in corneal epithelium in vivo. It suggests that this bioengineered corneal epithelium shared some characteristics of human limbal epithelium in vivo. This engineered epithelium was able to regenerate in 4 days following from a 4mm-diameter wound created by a filter paper soaked with 1 N NaOH. This corneal construct survived well after xeno-transplantation to the back of a nude mouse. The transplanted epithelium remained multilayer and became thicker with a phenotype similar to human corneal epithelium. Our findings demonstrate that natural corneal stroma is an optimal substrate for tissue bioengineering, and a native-like corneal construct has been created with epithelium containing limbal stem cells. This construct may have great potential for clinical use in

  7. Controlled opacity in a class of nonlinear dielectric media

    Science.gov (United States)

    Bittencourt, E.; Camargo, G. H. S.; De Lorenci, V. A.; Klippert, R.

    2017-03-01

    Motivated by new technologies for designing and tailoring metamaterials, we seek properties for certain classes of nonlinear optical materials that allow room for a reversibly controlled opacity-to-transparency phase transition through the application of external electromagnetic fields. We examine some mathematically simple models for the dielectric parameters of the medium and compute the relevant geometric quantities that describe the speed and polarization of light rays.

  8. The EOSTA model for opacities and EOS calculations

    Science.gov (United States)

    Barshalom, Avraham; Oreg, Joseph

    2007-11-01

    The EOSTA model developed recently combines the STA and INFERNO models to calculate opacities and EOS on the same footing. The quantum treatment of the plasma continuum and the inclusion of the resulted shape resonances yield a smooth behavior of the EOS and opacity global quantities vs density and temperature. We will describe the combined model and focus on its latest improvements. In particular we have extended the use of the special representation of the relativistic virial theorem to obtain an exact differential equation for the free energy. This equation, combined with a boundary condition at the zero pressure point, serves to advance the LDA EOS results significantly. The method focuses on applicability to high temperature and high density plasmas, warm dens matter etc. but applies at low temperatures as well treating fluids and even solids. Excellent agreement is obtained with experiments covering a wide range of density and temperature. The code is now used to create EOS and opacity databases for the use of hydro-dynamical simulations.

  9. Formation of Jupiter using opacities based on detailed grain physics

    CERN Document Server

    Movshovitz, Naor; Podolak, Morris; Lissauer, Jack J

    2010-01-01

    Numerical simulations, based on the core-nucleated accretion model, are presented for the formation of Jupiter at 5.2 AU in 3 primordial disks with three different assumed values of the surface density of solid particles. The grain opacities in the envelope of the protoplanet are computed using a detailed model that includes settling and coagulation of grains and that incorporates a recalculation of the grain size distribution at each point in time and space. We generally find lower opacities than the 2% of interstellar values used in previous calculations [Hubickyj, O., Bodenheimer, P., Lissauer, J. J., 2005. Icarus 179, 415--431; Lissauer, J. J., Hubickyj, O., D'Angelo, G., Bodenheimer, P., 2009. Icarus 199, 338-350]. These lower opacities result in more rapid heat loss from and more rapid contraction of the protoplanetary envelope. For a given surface density of solids, the new calculations result in a substantial speedup in formation time as compared with those previous calculations. Formation times are c...

  10. Lens opacities after repeated exposure to ultraviolet radiation.

    Science.gov (United States)

    Michael, R; Löfgren, S; Söderberg, P G

    1999-12-01

    To investigate the effect of the interval between two, near-threshold exposures to ultraviolet radiation (UVR) on cataract development. One eye of Sprague-Dawley rats was exposed twice to 4 kJ/m2 narrow band UVR (lambdaMAX=300 nm) for 15 min each. The interval between exposures was 0, 6, 24 or 48 h. One week after the first exposure both lenses were removed for photography and measurement of the intensity of forward light scattering to quantify lens opacities. All exposed lenses developed cataract. Forward light scattering was the same after double exposure with no interval or a 6 h interval. Forward light scattering after a 24 or 48 h interval was nearly twofold greater than that following no interval or a 6 h interval. The exposed lenses in all groups had mild anterior surface opacities and intense equatorial opacities as judged with a stereomicroscope. Two, near-threshold UVR exposures at 0 or a 6 h interval produce the same degree of lens opacification. When the second exposure follows 24 or 48 h after the first, lenticular damage increases. Repair processes between 24 and 48 h after exposure appear to be sensitive to UVR, and an additional exposure during this time may aggravate cataract development.

  11. Enforcement of opacity security properties for ship information system

    Directory of Open Access Journals (Sweden)

    Bowen Xing

    2016-09-01

    Full Text Available In this paper, we consider the cybersecurity issue of ship information system (SIS from a new perspective which is called opacity. For a SIS, its confidential information (named as “secret” may be leaked through the working behaviors of each Distributed Control Unit (DCU from an outside observer called an “intruder” which is able to determine ship's mission state by detecting the source of each data flow from the corresponding DCUs in SIS. Therefore we proposed a dual layer mechanism to enforce opacity by activating non-essential DCU during secret mission. This mechanism is calculated by two types of insertion functions: Safety-assured insertion function (fIS and Admissibility-assured insertion function (fIA. Due to different objectives, fIS is designed to confuse intruder by constructing a non-secret behaviors from a unsafe one, and the division of fIA is to polish the modified output behaviors back to normal. We define the property of “I2–Enforceability” that dual layer insertion functions has the ability to enforce opacity. By a given mission map of SIS and the marked secret missions, we propose an algorithm to select fIS and compute its matchable fIA and then the DCUs which should be activated to release non-essential data flow in each step is calculable.

  12. Corneal tomography and biomechanics in primary pterygium.

    Science.gov (United States)

    Vanathi, M; Goel, Sahil; Ganger, Anita; Agarwal, Tushar; Dada, T; Khokhar, Sudarshan

    2017-05-13

    To study the Scheimpflug's imaging and corneal biomechanics in primary pterygium. A prospective observational study of 55 patients with unilateral primary nasal pterygium was done. The normal fellow eyes of patients with pterygium were taken as controls. Clinical parameters noted included visual acuity, values of corneal curvature by doing Scheimpflug imaging, wavefront aberrations in terms of higher and lower-order aberrations and corneal hysteresis (CH) as well as corneal resistance factor (CRF) values by using ocular response analyzer. Of the total 55 patients, mean age was 43.0 + 11.4 years (range: 20-72 years). Mean LogMar uncorrected visual acuity in pterygium eyes and control eyes was 0.21 + 0.20 and 0.12 + 0.15, respectively (p = 0.016). On Scheimpflug imaging the mean anterior corneal curvature values (Ka1/Ka2 D) were 41.09 + 3.38/44.33 + 2.29 in pterygium eyes, 43.13 + 1.79/43.98 + 2.17 in control eyes (p  0.05). Analysis of corneal aberrations showed significantly higher corneal wavefront aberrations in pterygium eyes. Highest correlation of corneal astigmatism was noted with corneal area encroached by pterygium (ρ = 0.540 for LOA and 0.553 for HOA) and distance from pupillary center (ρ = 0.531 for LOA and 0.564 for HOA). Corneal biomechanical parameters including CH and CRF were found to be lower in the pterygium eyes, though not statistically significant (p value 0.60 and 0.59, respectively). Pterygium leads to deterioration of visual performance not only by causing refractive and topographic changes but also by causing a significant increase in corneal wavefront aberrations.

  13. Effective Tree Scattering and Opacity at L-Band

    Science.gov (United States)

    Kurum, Mehmet; O'Neill, Peggy E.; Lang, Roger H.; Joseph, Alicia T.; Cosh, Michael H.; Jackson, Thomas J.

    2011-01-01

    This paper investigates vegetation effects at L-band by using a first-order radiative transfer (RT) model and truck-based microwave measurements over natural conifer stands to assess the applicability of the tau-omega) model over trees. The tau-omega model is a zero-order RT solution that accounts for vegetation effects with effective vegetation parameters (vegetation opacity and single-scattering albedo), which represent the canopy as a whole. This approach inherently ignores multiple-scattering effects and, therefore, has a limited validity depending on the level of scattering within the canopy. The fact that the scattering from large forest components such as branches and trunks is significant at L-band requires that zero-order vegetation parameters be evaluated (compared) along with their theoretical definitions to provide a better understanding of these parameters in the retrieval algorithms as applied to trees. This paper compares the effective vegetation opacities, computed from multi-angular pine tree brightness temperature data, against the results of two independent approaches that provide theoretical and measured optical depths. These two techniques are based on forward scattering theory and radar corner reflector measurements, respectively. The results indicate that the effective vegetation opacity values are smaller than but of similar magnitude to both radar and theoretical estimates. The effective opacity of the zero-order model is thus set equal to the theoretical opacity and an explicit expression for the effective albedo is then obtained from the zero- and first- order RT model comparison. The resultant albedo is found to have a similar magnitude as the effective albedo value obtained from brightness temperature measurements. However, it is less than half of that estimated using the theoretical calculations (0.5 - 0.6 for tree canopies at L-band). This lower observed albedo balances the scattering darkening effect of the large theoretical albedo

  14. Corneal laceration caused by river crab

    Directory of Open Access Journals (Sweden)

    Vinuthinee N

    2015-01-01

    Full Text Available Naidu Vinuthinee,1,2 Anuar Azreen-Redzal,1 Jaafar Juanarita,1 Embong Zunaina2 1Department of Ophthalmology, Hospital Sultanah Bahiyah, Alor Setar, 2Department of Ophthalmology, School of Medical Sciences, Universiti Sains Malaysia, Kubang Kerian, Malaysia Abstract: A 5-year-old boy presented with right eye pain associated with tearing and photophobia of 1-day duration. He gave a history of playing with a river crab when suddenly the crab clamped his fingers. He attempted to fling the crab off, but the crab flew and hit his right eye. Ocular examination revealed a right eye corneal ulcer with clumps of fibrin located beneath the corneal ulcer and 1.6 mm level of hypopyon. At presentation, the Seidel test was negative, with a deep anterior chamber. Culture from the corneal scrapping specimen grew Citrobacter diversus and Proteus vulgaris, and the boy was treated with topical gentamicin and ceftazidime eyedrops. Fibrin clumps beneath the corneal ulcer subsequently dislodged, and revealed a full-thickness corneal laceration wound with a positive Seidel test and shallow anterior chamber. The patient underwent emergency corneal toileting and suturing. Postoperatively, he was treated with oral ciprofloxacin 250 mg 12-hourly for 1 week, topical gentamicin, ceftazidime, and dexamethasone eyedrops for 4 weeks. Right eye vision improved to 6/9 and 6/6 with pinhole at the 2-week follow-up following corneal suture removal. Keywords: corneal ulcer, pediatric trauma, ocular injury

  15. Corneal staining after treatment with topical tetracycline

    NARCIS (Netherlands)

    R. Lapid-Gortzak; C.P. Nieuwendaal; A.R. Slomovic; L. Spanjaard

    2006-01-01

    Purpose: The purpose of this paper is to report a case of corneal staining after treatment with topical tetracycline. Methods: A patient with crystalline keratopathy caused by Streptococcus viridans after corneal transplantation was treated topically with tetracycline eye drops, based on results of

  16. Corneal cellular proliferation and wound healing

    OpenAIRE

    Gan, Lisha

    2000-01-01

    Background. Cellular proliferation plays an important role in both physiological and pathological processes. Epithelial hyperplasia in the epithelium, excessive scar formation in retrocorneal membrane formation and neovascularization are examples of excessive proliferation of cornea cells. Lack of proliferative ability causes corneal degeneration. The degree of proliferative and metabolic activity will directly influence corneal transparency and very evidently refractive res...

  17. Corynebacterium macginleyi isolated from a corneal ulcer

    Directory of Open Access Journals (Sweden)

    Kathryn Ruoff

    2010-02-01

    Full Text Available We report the isolation of Corynebacterium macginleyi from the corneal ulcer culture of a patient, later enrolled in the Steroids for Corneal Ulcer Trial (SCUT. To our knowledge this is the first published report from North America of the recovery of C. macginleyi from a serious ocular infection.

  18. Dorsally located corneal dermoid in a cat

    Directory of Open Access Journals (Sweden)

    Alexander J LoPinto

    2016-04-01

    Full Text Available Case summary A 2-month-old, male kitten was presented for evaluation of unilateral blepharospasm and epiphora involving the right eye. Ocular examination revealed conjunctivitis, a superficial corneal ulcer, reflex anterior uveitis and a haired mass within the dorsal cornea of the right eye. The mass was subsequently removed surgically via a lamellar keratectomy. Histologic evaluation of the mass via light microscopy revealed it to be comprised of normal-haired skin with mild inflammation. One week after surgical removal and medical management of the corneal ulcer, all ocular clinical signs had resolved with minimal corneal scarring. On re-examination 6 months following surgical excision of the mass, the kitten was noted to be comfortable with no significant corneal scarring. Relevance and novel information To our knowledge, this is the first case report of a dorsally located corneal dermoid in a cat.

  19. Corneal Topographical Changes Flollowing Strabismus Surgery

    Institute of Scientific and Technical Information of China (English)

    MaiGH; WangZ

    1999-01-01

    Purpose:To study corneal topographical changes after strabismus surgery.Methods:Computer-aided corneal topography was used in 43 strabismus patients(45 eyes)one or two days prior to and six or seven ays after strabismus surgery.The spherical and cylindrical equivalents were calculated based on the simulated keratometry.Results:After the surgery,only the changes at 3mm in the inferior quadrant were statistically significant.The changes at 3mm in the rest quadrants and the changes at 7mm were no significant.Significant changes in spherical equivalent were found post-operatively.neither the horizontal nor the verical meridional equivalent showed significant changes after surgery.Conclusions:The results of corneal topographical changes following strabismus surgery in our preliminary study indicated the little effect of strabismus surgery on corneal curvature and corneal astigmatism.

  20. Corneal neovascularization and contemporary antiangiogenic therapeutics.

    Science.gov (United States)

    Hsu, Chih-Chien; Chang, Hua-Ming; Lin, Tai-Chi; Hung, Kuo-Hsuan; Chien, Ke-Hung; Chen, Szu-Yu; Chen, San-Ni; Chen, Yan-Ting

    2015-06-01

    Corneal neovascularization (NV), the excessive ingrowth of blood vessels from conjunctiva into the cornea, is a common sequela of disease insult that can lead to visual impairment. Clinically, topical steroid, argon laser photocoagulation, and subconjunctival injection of bevacizumab have been used to treat corneal NV. Sometimes, the therapies are ineffective, especially when the vessels are large. Large vessels are difficult to occlude and easily recanalized. Scientists and physicians are now dedicated to overcoming this problem. In this article, we briefly introduce the pathogenesis of corneal NV, and then highlight the existing animal models used in corneal NV research-the alkali-induced model and the suture-induced model. Most of all, we review the potential therapeutic targets (i.e., vascular endothelial growth factor and platelet-derived growth factor) and their corresponding inhibitors, as well as the immunosuppressants that have been discovered in recent years by corneal NV studies.

  1. Plasma polymer-coated contact lenses for the culture and transfer of corneal epithelial cells in the treatment of limbal stem cell deficiency.

    Science.gov (United States)

    Brown, Karl David; Low, Suet; Mariappan, Indumathi; Abberton, Keren Maree; Short, Robert; Zhang, Hong; Maddileti, Savitri; Sangwan, Virender; Steele, David; Daniell, Mark

    2014-02-01

    Extensive damage to the limbal region of the cornea leads to a severe form of corneal blindness termed as limbal stem cell deficiency (LSCD). Whereas most cases of corneal opacity can be treated with full thickness corneal transplants, LSCD requires stem cell transplantation for successful ocular surface reconstruction. Current treatments for LSCD using limbal stem cell transplantation involve the use of murine NIH 3T3 cells and human amniotic membranes as culture substrates, which pose the threat of transmission of animal-derived pathogens and donor tissue-derived cryptic infections. In this study, we aimed to produce surface modified therapeutic contact lenses for the culture and delivery of corneal epithelial cells for the treatment of LSCD. This approach avoids the possibility of suture-related complications and is completely synthetic. We used plasma polymerization to deposit acid functional groups onto the lenses at various concentrations. Each surface was tested for its suitability to promote corneal epithelial cell adhesion, proliferation, retention of stem cells, and differentiation and found that acid-based chemistries promoted better cell adhesion and proliferation. We also found that the lenses coated with a higher percentage of acid functional groups resulted in a higher number of cells transferred onto the corneal wound bed in rabbit models of LSCD. Immunohistochemistry of the recipient cornea confirmed the presence of autologous, transplanted 5-bromo-2'-deoxyuridine (BrdU)-labeled cells. Hematoxylin staining has also revealed the presence of a stratified epithelium at 26 days post-transplantation. This study provides the first evidence for in vivo transfer and survival of cells transplanted from a contact lens to the wounded corneal surface. It also proposes the possibility of using plasma polymer-coated contact lenses with high acid functional groups as substrates for the culture and transfer of limbal cells in the treatment of LSCD.

  2. Corneal Regeneration by Deep Anterior Lamellar Keratoplasty (DALK Using Decellularized Corneal Matrix.

    Directory of Open Access Journals (Sweden)

    Yoshihide Hashimoto

    Full Text Available The purpose of this study is to demonstrate the feasibility of DALK using a decellularized corneal matrix obtained by HHP methodology. Porcine corneas were hydrostatically pressurized at 980 MPa at 10°C for 10 minutes to destroy the cells, followed by washing with EGM-2 medium to remove the cell debris. The HHP-treated corneas were stained with H-E to assess the efficacy of decellularization. The decellularized corneal matrix of 300 μm thickness and 6.0 mm diameter was transplanted onto a 6.0 mm diameter keratectomy wound. The time course of regeneration on the decellularized corneal matrix was evaluated by haze grading score, fluorescein staining, and immunohistochemistry. H-E staining revealed that no cell nuclei were observed in the decellularized corneal matrix. The decellularized corneal matrices were opaque immediately after transplantation, but became completely transparent after 4 months. Fluorescein staining revealed that initial migration of epithelial cells over the grafts was slow, taking 3 months to completely cover the implant. Histological sections revealed that the implanted decellularized corneal matrix was completely integrated with the receptive rabbit cornea, and keratocytes infiltrated into the decellularized corneal matrix 6 months after transplantation. No inflammatory cells such as macrophages, or neovascularization, were observed during the implantation period. The decellularized corneal matrix improved corneal transparency, and remodelled the graft after being transplanted, demonstrating that the matrix obtained by HHP was a useful graft for corneal tissue regeneration.

  3. Radiation attenuation and opacity in smoke and water sprays

    Science.gov (United States)

    Parent, Gilles; Boulet, Pascal; Morlon, Romain; Blanchard, Elizabeth

    2017-08-01

    Radiation attenuation through sprays, smoke and mixings of both media was studied in the infrared and in the visible range, by conducting real scale experiments in a corridor. The effect of water injection by a water mist nozzle and a sprinkler device was investigated. Radiation attenuation in the infrared range and opacity in the visible range were measured, by using a FTIR spectrometer and a dedicated opacimetry device especially designed for the present application. Experiments were done using either a blackbody source for attenuation characterization, or a heptane pool fire aimed at producing smoke for opacity measurements. For tests with smoke, the difficulties raised by the harsh environment involving a hot mixing of gas plus soot and vapor carrying water droplets were circumvented with an original device involving an optical fiber network. Mean infrared transmission was found equal to 12% for the water mist (with a 25 L/min water flowrate) and 37% for the sprinkler (with a 91 L/min water flowrate). Fitting the infrared transmission spectra with results obtained using a Monte Carlo simulation provided an estimation of the water volumetric fraction in the spray. It was shown that the better attenuation capability of the water mist is due to two factors: (1) a higher extinction coefficient of the water mist for a given water volumetric fraction due to the small size of the injected droplets and (2) a higher water volumetric fraction. Opacity measurements in the visible range yielded a measured extinction coefficient in good agreement with an estimation obtained with the Mie theory and the identified water volumetric fraction. Moreover, the water sprays (sprinkler or water mist) was seen to lead to a quick de-stratification of the smoke layer. When the spraying operation was stopped, the visibility re-increased in two main steps: a first step of fast increase and a second step of slow increase needing a few tens of seconds to get again a fully stratified smoke

  4. Sound speed and oscillation frequencies for solar models evolved with Los Alamos ATOMIC opacities

    CERN Document Server

    Guzik, Joyce A; Walczak, P; Wood, S R; Mussack, K; Farag, E

    2016-01-01

    Los Alamos National Laboratory has calculated a new generation of radiative opacities (OPLIB data using the ATOMIC code) for elements with atomic number Z=1-30 with improved physics input, updated atomic data, and finer temperature grid to replace the Los Alamos LEDCOP opacities released in the year 2000. We calculate the evolution of standard solar models including these new opacities, and compare with models evolved using the Lawrence Livermore National Laboratory OPAL (Iglesias and Rogers 1996) opacities. We use the solar abundance mixture of Asplund et al. (2009). The new Los Alamos ATOMIC opacities have steeper opacity derivatives than those of OPAL for temperatures and densities of the solar interior radiative zone. We compare the calculated nonadiabatic solar oscillation frequencies and solar interior sound speed to observed frequencies and helioseismic inferences. The calculated sound-speed profiles are similar for models evolved using either the updated Iben evolution code (see \\cite{Guzik2010}), or ...

  5. Prevalence of Lens Opacities in Adult Chinese Americans: The Chinese American Eye Study (CHES)

    OpenAIRE

    Varma, Rohit; Sun, Jie; Torres, Mina; Wu, Shuang; Hsu, Chunyi; Azen, Stanley Paul; McKean-Cowdin, Roberta; ,

    2016-01-01

    Purpose We determined the age- and sex-specific prevalence of posterior subcapsular (PSC), nuclear, cortical, and mixed lens opacities in a population-based sample of Chinese-American adults. Methods A population-based sample of Chinese-Americans 50 years and older, from 10 census tracts in Monterey Park, CA, USA, underwent a detailed interview and a comprehensive clinical examination that included assessment of different types of lens opacities by the slit-lamp–based Lens Opacities Classific...

  6. FTS measurements of submillimeter opacity and other site testing at Pampa la Bola

    Science.gov (United States)

    Matsushita, Satoki; Matsuo, Hiroshi; Sakamoto, Akihiro; Pardo, Juan R.

    2000-07-01

    We have carried out Fourier Transform Spectrometer (FTS) measurements of the millimeter and submillimeter-wave (150 - 1500 GHz or 2 mm - 200 micrometer) atmospheric opacity at Pampa la Bola, 4800 m above sea level in northern Chile on September 1997 and June 1998. One of the best transmission spectra show up to approximately 67% transmission at well- known submillimeter-wave windows. Supra-terahertz windows (located around 1035 GHz, 1350 GHz, and 1500 GHz) were identified in the same spectrum. The observed spectra can be well modeled by newly developed radiative-transfer calculations. Correlations between 220 GHz opacities and those of the center of submillimeter-wave windows or even those of the supra-terahertz windows are obtained using the entire data set. Good correlations were obtained except for the periods affected by the liquid water opacity component. We succeeded to separate the total opacity in two parts: the water vapor opacity and the liquid water opacity, using two frequencies, one in the millimeter domain and another one in the submillimeter. The separated water vapor opacity component shows good correlation with the 183 GHz pure water vapor line opacity which is also covered in the measured spectra, but the liquid water opacity component shows no correlation. The liquid water opacity component also shows no correlation with the phase fluctuation measured with the 11 GHz radio seeing monitor. Modeling of this component is currently under way. Combined with a statistical study of the 225 GHz opacity data of the Chajnantor site (approximately 7 km apart from Pampa la Bola), it is estimated that submillimeter-wave observations can be done with zenith opacity less than 1.0 (at the most transparent frequency in those windows) for about 50% of the winter season, assuming no presence of liquid water absorption.

  7. Factors Affecting Corneal Hysteresis in Taiwanese Adults

    Institute of Scientific and Technical Information of China (English)

    Jia-Kang Wang; Tzu-Lun Huang; Pei-Yuan Su; Pei-Yao Chang

    2015-01-01

    Purpose: To investigate the correlation of various corneal hysteresis (CH) factors in Chinese adults. Methods: From January 2009 to November 2011, the healthy right eyes of a total of 292 adults were recruited into the study. Goldmann-correlated intraocular pressure (IOPG) and CH were measured using an ocular response analyzer (ORA). Central corneal thickness was measured using the ORA’s in-tegrated handheld ultrasonic pachymeter. The IOLMaster was used to obtain the ocular biometric measurements including axial length, anterior chamber depth, and keratometric values. The Pearson correlation coefficient was used to test correla-tions between CH and quantitative factors. The chi-square test was used to detect differences in categorical values. Results: Longer axial length (P=0.0001), lower IOPG (P=0.03), older age(P=0.003),and thinner central corneal thick-ness (P=0.0001) were significantly associated with lower CH. The anterior chamber depth (P=0.34), gender (P=0.23), and corneal curvature (P=0.18) had no relationship to CH. Conclusion:Various factors including axial length, intraocular pressure, age, and central corneal thickness can affect measure-ment of corneal biomechanical properties in Chinese adults. But the anterior chamber depth, gender, and corneal curvature were irrelevant to CH.

  8. Corneal sensitivity in five horse breeds

    Directory of Open Access Journals (Sweden)

    Eunice Santos de Andrade

    Full Text Available ABSTRACT: This study aimed to determine and compare corneal sensitivity values in different regions of the cornea in five horse breeds. One hundred and forty five healthy horses, adults of both sexes, of the following breeds - Arabian horse (AH; n=20, Mangalarga Marchador (MM; n=50, Pure Blood Lusitano (PBL; n=35, Quarter Horse (QH; n=20, Brazilian Sport Horse (BSH; n=20-were investigated. Corneal touch threshold (CTT was measured with a Cochet-Bonnet esthesiometer in five different corneal regions. Measurements of the median central CTT were: 4.50±0.50cm (AH, 3.50±0.56cm (MM, 3.00±0.25cm (PBL, 2.50±0.44cm (QH and 2.50±0.00cm (BSH. The central region was the most sensitive and the dorsal region the least sensitive corneal region for all breeds. CTT values differed for corneal regions and horse breeds. The CTT values were different among the corneal regions and the horse breeds. Arabian horses presented higher sensitivity values being the most sensitive in all of the corneal regions.

  9. Corneal topographic changes following retinal surgery

    Directory of Open Access Journals (Sweden)

    Pandey RM

    2004-08-01

    Full Text Available Abstract Background To study the effect of retinal/ vitreoretinal surgeries on corneal elevations. Methods Patients who underwent retinal/ vitreoretinal surgeries were divided into 3 groups. Scleral buckling was performed in 11 eyes (Group 1. In 8 (25% eyes, vitreoretinal surgery was performed along with scleral buckling (Group 2. In 12 eyes, pars plana vitrectomy was performed for vitreous hemorrhage (Group 3. An encircling element was used in all the eyes. The parameters evaluated were best-corrected visual acuity (BCVA, change in axial length, and corneal topographic changes on Orbscan topography system II, preoperative and at 12 weeks following surgery. Results There was a statistically significant increase in anterior corneal elevation in all the three groups after surgery (p = 0.003, p = 0.008 & p = 0.003 respectively. The increase in posterior corneal elevation was highly significant in all the three groups after surgery (p = 0.0000, p = 0.0001 & p = 0.0001 respectively. The increase in the posterior corneal elevation was more than the increase in the anterior elevation and was significant statistically in all the three groups (group I: p = 0.02; group II: p = 0.01; group III: p = 0.008. Conclusions Retinal/ vitreoretinal surgeries cause a significant increase in the corneal elevations and have a greater effect on the posterior corneal surface.

  10. Differences between real and predicted corneal shapes after aspherical corneal ablation

    Science.gov (United States)

    Anera, Rosario G.; Villa, César; Jiménez, José R.; Gutiérrez, Ramón; Jiménez del Barco, Luis

    2005-07-01

    We study the differences between real and expected corneal shapes, using an aspherical ablation algorithm with a known equation and avoiding the limitation imposed by most studies of refractive surgery in which the ablation equations are not known. We have calculated the theoretical corneal shape predicted by this algorithm, comparing this shape with the real corneal topography. The results indicate that the deviations that appear in the corneal shape are significant for visual performance and for the correction of eye aberrations. If we include in this analysis the effect of reflection losses and nonnormal incidence on the cornea, we can reduce corneal differences, but they will remain significant. These results confirm that it is essential to minimize corneal differences to achieve effective correction in refractive surgery.

  11. Detailed Opacity Comparison for an Improved Stellar Modeling of the Envelopes of Massive Stars

    Science.gov (United States)

    Turck-Chièze, S.; Le Pennec, M.; Ducret, J. E.; Colgan, J.; Kilcrease, D. P.; Fontes, C. J.; Magee, N.; Gilleron, F.; Pain, J. C.

    2016-06-01

    Seismic observations have led to doubts or ambiguities concerning the opacity calculations used in stellar physics. Here, we concentrate on the iron-group opacity peak, due to iron, nickel, and chromium, located around T = 200,000 K for densities from {10}-8 {to} {10}-4 {{g}} {{cm}}-3, which creates some convective layers in stellar radiative envelopes for masses between 3 and 18 {M}⊙ . These conditions were extensively studied in the 1980s. More recently, inconsistencies between OP and OPAL opacity calculations have complicated the interpretation of seismic observations as the iron-group opacity peak excites acoustic and gravity modes in SPB, β Cephei, and sdB stars. We investigate the reliability of the theoretical opacity calculations using the modern opacity codes ATOMIC and SCO-RCG. We show their temperature and density dependence for conditions that are achievable in the laboratory and equivalent to astrophysical conditions. We also compare new theoretical opacity spectra with OP spectra and quantify how different approximations impact the Rosseland mean calculations.This detailed study estimates new ATOMIC and SCO-RCG Rosseland mean values for astrophysical conditions which we compare to OP values. Some puzzling questions are still under investigation for iron, but we find a strong increase in the Rosseland mean nickel opacity of a factor between 2 and 6 compared to OP. This appears to be due to the use of extrapolated atomic data for the Ni opacity within the OP calculations. A study on chromium is also shown.

  12. Morphological evaluation of normal human corneal epithelium

    DEFF Research Database (Denmark)

    Ehlers, Niels; Heegaard, Steffen; Hjortdal, Jesper

    2010-01-01

    PURPOSE: The human corneal epithelium is usually described as a 50-µm-thick layer of regular stratified squamous non-keratinized cells with a thickness of 5-7 cells. The purpose of this study is systemically to revisit the histopathological appearance of 100 corneas. METHODS: 5-µm-thick sections...... in Bowman's membrane. No intraepithelial microcysts, as found in Meesmann corneal dystrophy, were observed. CONCLUSION: The total corneal thickness was higher than reported in in vivo studies and with a wider variation. This may be an effect of uncontrolled swelling and dehydration during preparation...

  13. Evidence for Environmental Changes in the Submillimeter Dust Opacity

    CERN Document Server

    Martin, Peter G; Bontemps, Sylvain; Miville-Deschênes, Marc-Antoine; Ade, Peter A R; Bock, James J; Chapin, Edward L; Devlin, Mark J; Dicker, Simon R; Griffin, Matthew; Gundersen, Joshua O; Halpern, Mark; Hargrave, Peter C; Hughes, David H; Klein, Jeff; Marsden, Gaelen; Mauskopf, Philip; Netterfield, Calvin B; Olmi, Luca; Patanchon, Guillaume; Rex, Marie; Scott, Douglas; Semisch, Christopher; Truch, Matthew D P; Tucker, Carole; Tucker, Gregory S; Viero, Marco P; Wiebe, Donald V

    2011-01-01

    The submillimeter opacity of dust in the diffuse Galactic interstellar medium (ISM) has been quantified using a pixel-by-pixel correlation of images of continuum emission with a proxy for column density. We used three BLAST bands at 250, 350, and 500 \\mu m and one IRAS at 100 \\mu m. The proxy is the near-infrared color excess, E(J-Ks), obtained from 2MASS. Based on observations of stars, we show how well this color excess is correlated with the total hydrogen column density for regions of moderate extinction. The ratio of emission to column density, the emissivity, is then known from the correlations, as a function of frequency. The spectral distribution of this emissivity can be fit by a modified blackbody, whence the characteristic dust temperature T and the desired opacity \\sigma_e(1200) at 1200 GHz can be obtained. We have analyzed 14 regions near the Galactic plane toward the Vela molecular cloud, mostly selected to avoid regions of high column density (N_H > 10^{22} cm^-2) and small enough to ensure a u...

  14. Iron Opacity Platform Performance Characterization at the National Ignition Facility

    Science.gov (United States)

    Opachich, Y. P.; Ross, P. W.; Heeter, R. F.; Barrios, M. A.; Liedahl, D. A.; May, M. J.; Schneider, M. B.; Craxton, R. S.; Garcia, E. M.; McKenty, P. W.; Zhang, R.; Weaver, J. L.; Flippo, K. A.; Kline, J. L.; Perry, T. S.; Los Alamos National Laboratory Collaboration; Naval Research Laboratory Collaboration; University of Rochester LaboratoryLaser Energetics Collaboration; Lawrence Livermore National Lab Collaboration; National Security Technologies, LLC Collaboration

    2016-10-01

    A high temperature opacity platform has been fielded at the National Ignition Facility (NIF). The platform will be used to study opacity in iron at a temperature of 160 eV. The platform uses a 6 mm diameter hohlraum driven by 128 laser beams with 530 kJ of energy in a 3 ns pulse to heat an iron sample. Absorption spectra of the heated sample are generated with a broadband pulsed X-ray backlighter produced by imploding a vacuum-filled CH shell. The shell is 2 mm in diameter and 20 microns thick, driven by 64 beams with 250 kJ in a 2.5 ns pulse. The hohlraum and backlighter performance have both been investigated recently and will be discussed in this presentation. This work was performed by National Security Technologies, LLC, under Contract No. DE-AC52-06NA25946 with the U.S. Department of Energy. DOE/NV/25946-2892.

  15. Iron Opacity and the Pulsar of SN 1987A

    CERN Document Server

    Fryer, C L; Pinto, P A

    1999-01-01

    Neutron stars formed in Type II supernovae are likely to be initially obscured by late-time fallback. Although much of the late-time fallback is quickly accreted via neutrino cooling, some material remains on the neutron star, forming an atmosphere which slowly accretes through photon emission. In this paper, we derive structure equations of the fallback atmosphere and present results of one-dimensional simulations of that fallback. The atmosphere remaining after neutrino cooling becomes unimportant (less than the Compton Eddington limit) is only a fraction of the total mass accreted (10^-8 of the accreted mass or 10^-9 solar masses.) Recombined iron dominates the opacity in the outer regions leading to an opacity 1000-10,000 times higher than that of electron scattering alone. The resultant photon emission of the remnant atmosphere is limited to 1/1000th the Compton Eddington Luminosity. The late-time evolution of this system leads to the formation of a photon-driven wind from the accretion of the inner port...

  16. New dust opacity mapping from Viking Infrared Thermal Mapper data

    Science.gov (United States)

    Martin, Terry Z.; Richardson, Mark I.

    1993-01-01

    Global dust opacity mapping for Mars has been carried forward using the approach described by Martin (1986) for Viking IR Thermal Mapper data. New maps are presented for the period from the beginning of Viking observations, until Ls 210 deg in 1979 (1.36 Mars years). This range includes the second and more extensive planet-encircling dust storm observed by Viking, known as storm 1977b. Improvements in approach result in greater time resolution and smaller noise than in the earlier work. A strong local storm event filled the Hellas basin at Ls 170 deg, prior to the 1977a storm. Dust is retained in equatorial regions following the 1977b storm far longer than in mid-latitudes. Minor dust events appear to raise the opacity in northern high latitudes during northern spring. Additional mapping with high time resolution has been done for the periods of time near the major storm origins in order to search for clues to the mechanism of storm initiation. The first evidence of the start of the 1977b storm is pushed back to Ls 274.2 deg, preceding signs of the storm in images by about 15 hours.

  17. Galactic cold cores VI. Dust opacity spectral index

    CERN Document Server

    Juvela, M; Doi, Y; Hughes, A; Lefevre, C; Marshall, D J; Meny, C; Montillaud, J; Pagani, L; Paradis, D; Ristorcelli, I; Malinen, J; Montier, L A; Paladini, R; Pelkonen, V -M; Rivera-Ingraham, A

    2015-01-01

    The Galactic Cold Cores project has made Herschel observations of 116 fields where the Planck survey has found signs of cold dust emission. The fields contain sources in different environments and different phases of star formation. The dust opacity spectral index beta and the dust colour temperature T are derived using Herschel and Planck data. The relation between beta and T is examined for the whole sample and inside individual fields. Based on IRAS and Planck data, the fields are characterised by a median colour temperature of 16.1 K and a median opacity spectral index of beta=1.84. We observe a clear T-beta anti-correlation. In Herschel observations, constrained at lower resolution by Planck data, the variations follow the column density structure and beta(FIR) can rise to ~2.2 in individual clumps. The Planck 217 GHz band shows a systematic excess that is consistent with a general flattening of the dust emission spectrum at millimetre wavelengths. When fitted separately below and above 700 um, the media...

  18. Polar Value Analysis of Corneal Astigmatism in Intrastromal Corneal Ring Segment Implantation

    Science.gov (United States)

    Rho, Chang Rae; Kim, Min-Ji

    2016-01-01

    Purpose. To evaluate surgically induced astigmatism (SIA) and the average corneal power change in symmetric intrastromal corneal ring segment (ICRS) implantation. Methods. The study included 34 eyes of 34 keratoconus patients who underwent symmetric Intacs SK ICRS implantation. The corneal pocket incision meridian was the preoperative steep meridian. Corneal power data were obtained before and 3 months after Intacs SK ICRS implantation using scanning-slit topography. Polar value analysis was used to evaluate the SIA. Hotelling's trace test was used to compare intraindividual changes. Results. Three months postoperatively, the combined mean polar value for SIA changed significantly (Hotelling's T2 = 0.375; P = 0.006). The SIA was 1.54 D at 99° and the average corneal power decreased significantly by 3.8 D. Conclusion. Intacs SK ICRS placement decreased the average corneal power and corneal astigmatism compared to the preoperative corneal power and astigmatism when the corneal pocket incision was made at the preoperative steep meridian. PMID:27795856

  19. Polar Value Analysis of Corneal Astigmatism in Intrastromal Corneal Ring Segment Implantation

    Directory of Open Access Journals (Sweden)

    Chang Rae Rho

    2016-01-01

    Full Text Available Purpose. To evaluate surgically induced astigmatism (SIA and the average corneal power change in symmetric intrastromal corneal ring segment (ICRS implantation. Methods. The study included 34 eyes of 34 keratoconus patients who underwent symmetric Intacs SK ICRS implantation. The corneal pocket incision meridian was the preoperative steep meridian. Corneal power data were obtained before and 3 months after Intacs SK ICRS implantation using scanning-slit topography. Polar value analysis was used to evaluate the SIA. Hotelling’s trace test was used to compare intraindividual changes. Results. Three months postoperatively, the combined mean polar value for SIA changed significantly (Hotelling’s T2=0.375; P=0.006. The SIA was 1.54 D at 99° and the average corneal power decreased significantly by 3.8 D. Conclusion. Intacs SK ICRS placement decreased the average corneal power and corneal astigmatism compared to the preoperative corneal power and astigmatism when the corneal pocket incision was made at the preoperative steep meridian.

  20. MMSC-LIKE LIMBAL CELLS COTRANSPLANTATION PROMOTES LOCAL IMMUNOCORRECTION AND CORNEAL GRAFT TRANSPARENT RETENTION IN HIGH RISK KERATOPLASTY

    Directory of Open Access Journals (Sweden)

    S. A. Borzenok

    2014-01-01

    Full Text Available Aim was to evaluate clinical results of donor corneal graft survival in high-risk recipients in co-transplantation of preserved allogenic limbal grafts. Materials and methods. Two types of penetrative keratoplasties were carried out in patients with corneal graft opacities and high risk of rejection (n = 69. Co-transplantation of donor cornea and allogenic MMSC-like limbal cells in the form of limbal transplants was carried out in the 1st group (n = 36; in the 2nd group (n = 33 only the cornea was transplanted. Results. Observation of the patients during one year after surgery showed that the rate of transparent cornea engraftment increased in the 1st group (86,1 against 69,7% in the 2nd group. The density of endothelial cells was also higher in the 1st group (85,9 against 76,2% in the 2nd group. At the same time, progressive decreasing of pro-inflammatory cytokines (IL-6, IFNγ, TNFα and increasing of anti-inflammatory cytokines (IL-10, IL-1RA, TGFβ along with higher level of HLA-G5 were revealed in the recipients’ tear fluid in the 1st group in comparison to the 2nd group. Conclusion. Simultaneous transplantation of preserved limbal grafts with corneal graft in high-risk keratoplasty favors the transparent cornea engraftment, obviously, this is due to immunoregulatory activity of the MMSC-like limbal cells. 

  1. Keratitis after Implantation of Intrastromal Corneal Rings with Spontaneous Extrusion of the Segment

    Directory of Open Access Journals (Sweden)

    Juan Ibáñez-Alperte

    2010-09-01

    Full Text Available Purpose: To report a case of bacterial keratitis in a patient with a history of intrastromal corneal ring segments (INTACS® implantation to correct keratoconus. Methods: The patient’s history, clinical presentation, pathological analysis and therapeutic management were reviewed. Results: A 36-year-old-man was referred to our department due to decreased vision and intense pain in his left eye, 40 days after INTACS® implantation for keratoconus. Slit-lamp examination revealed epithelial defects and stromal infiltrates in the lower channel without evidence of the inferior ring. The anterior chamber also showed a significant fibrin reaction to hypopyon. A low-tension suture was removed at the site of the incision. Microbiological study of the conjunctival swab was positive for Staphylococcus epidermidis, but the corneal culture was sterile. The patient was treated with topical fortified and systemic antibiotics. The infection slowly resolved, leaving opacity at the inferior segment site. Conclusions: Infectious keratitis following INTACS implantation is an infrequent complication that can have important consequences without suitable and early therapeutic management.

  2. Surgical compensation of presbyopia with corneal inlays.

    Science.gov (United States)

    Konstantopoulos, Aris; Mehta, Jodhbir S

    2015-05-01

    Presbyopia, the physiological change in near vision that develops with ageing, gradually affects individuals older than 40 years and is a growing cause of visual disability due to ageing demographics of the global population. The routine use of computers and 'smartphones', combined with the affluence of the 'baby boomers' generation has set high standards for near vision correction. Corneal inlays are a relatively new treatment modality that is effective at compensating for presbyopia. The dimensions of these devices vary from 2 to 3.8 mm in diameter and 5 to 32 μm in thickness. They are implanted in the anterior corneal stroma of the non-dominant eye, most commonly, in a femtosecond laser created corneal pocket. They improve near vision by increasing the depth of focus, creating a hyper-prolate region of increased central cornea power or providing a refractive add power. This article reviews the literature on the efficacy and safety of corneal inlays.

  3. Conjunctival intraepithelial neoplasia with corneal furrow degeneration

    Directory of Open Access Journals (Sweden)

    Pukhraj Rishi

    2014-01-01

    Full Text Available A 68-year-old man presented with redness of left eye since six months. Examination revealed bilateral corneal furrow degeneration. Left eye lesion was suggestive of conjunctival squamous cell carcinoma, encroaching on to cornea. Anterior segment optical coherence tomography (AS-OCT confirmed peripheral corneal thinning. Fluorescein angiography confirmed intrinsic vascularity of lesion. Patient was managed with "no touch" surgical excision, dry keratectomy without alcohol, cryotherapy, and primary closure. Pathologic examination of removed tissue confirmed clinical diagnosis. Management of this particular case required modification of standard treatment protocol. Unlike the alcohol-assisted technique of tumor dissection described, ethyl alcohol was not used for risk of corneal perforation due to underlying peripheral corneal thinning. Likewise, topical steroids were withheld in the post-operative period. Three weeks post-operatively, left eye was healing well. Hence, per-operative usage of absolute alcohol and post-operative use of topical steroids may be best avoided in such eyes.

  4. Grain opacity and the bulk composition of extrasolar planets. II. An analytical model for the grain opacity in protoplanetary atmospheres

    CERN Document Server

    Mordasini, C

    2014-01-01

    Context. We investigate the grain opacity k_gr in the atmosphere of protoplanets. This is important for the planetary mass-radius relation since k_gr affects the H/He envelope mass of low-mass planets and the critical core mass of giant planets. Aims. The goal of this study is to derive an analytical model for k_gr. Methods. Our model is based on the comparison of the timescales of microphysical processes like grain settling in the Stokes and Epstein regime, growth by Brownian motion coagulation and differential settling, grain evaporation, and grain advection due to envelope contraction. With these timescales we derive the grain size, abundance, and opacity. Results. We find that the main growth process is differential settling. In this regime, k_gr has a simple functional form and is given as 27 Q/8 H rho in the Epstein regime and as 2 Q/H rho for Stokes drag. Grain dynamics lead to a typical radial structure of k_gr with high ISM-like values in the top layers but a strong decrease in the deeper parts where...

  5. Corneal topography and soft contact lens fit.

    Science.gov (United States)

    Young, Graeme; Schnider, Cristina; Hunt, Chris; Efron, Suzanne

    2010-05-01

    To determine which ocular topography variables affect soft contact lens fit. Fifty subjects each wore three pairs of soft lenses in random succession (Vistakon Acuvue 2, Vistakon Acuvue Advance, Ciba Vision Night & Day), and various aspects of lens fit were evaluated. The steeper base curves of each type were worn in one eye and the flatter base curves in the other eye. Corneal topography data were collected using a Medmont E300 corneal topographer (Camberwell, Australia). Corneal curvature, shape factor (SF), and corneal height were measured over a 10 mm chord and also over the maximum measurable diameter. These were measured in the horizontal, vertical, steepest, and flattest meridians. With each lens type, the steeper base curve provided the best fit on the greatest proportion of eyes and the significant differences in various aspects of fit were noted between base curves. For each lens type, there was no significant difference in mean K-reading between those eyes best fit with the steeper base curve and those eyes best fit with the flatter base curve. Two of the lenses showed a positive correlation between centration and horizontal corneal height (maximum), whereas one lens showed a negative correlation between centration and horizontal SF (SF = e). Several lenses showed a positive correlation between post-blink movement and horizontal or vertical corneal SF. The measurement of corneal topography using current Placido disc instrumentation allows a better prediction of soft lens fit than by keratometry, but it is not reliable enough to enable accurate selection of the best fitting base curve. Some correlations are evident between corneal measurements; however, trial fitting remains the method of choice for selection of soft lens base curve.

  6. Serological profile of candidates for corneal donation

    OpenAIRE

    Adroaldo Lunardelli; Richard Beraldini Alvarenga; Maria Luiza Assmann; Dário Eduardo de Lima Brum; Mirna Adolfina Barison

    2014-01-01

    Objetive: The purpose of this study is to map the serological profile of candidates to corneal donation at Irmandade Santa Casa de Misericórdia de Porto Alegre, identifying the percentage of disposal by serology and the marker involved. Methods: There have been analised – retrospectively – the results of serology of all corneal donors, made between the period of 1st january 2006 and 31st december 2012. Data analised were related to age, gender and the results of serology pert...

  7. Asphericity analysis using corneal wavefront and topographic meridional fits

    Science.gov (United States)

    Arba-Mosquera, Samuel; Merayo-Lloves, Jesús; de Ortueta, Diego

    2010-03-01

    The calculation of corneal asphericity as a 3-D fit renders more accurate results when it is based on the corneal wavefront aberrations rather than on the corneal topography of the principal meridians. A more accurate prediction could be obtained for hyperopic treatments compared to myopic treatments. We evaluate a method to calculate corneal asphericity and asphericity changes after refractive surgery. Sixty eyes of 15 consecutive myopic patients and 15 consecutive hyperopic patients (n=30 each) are retrospectively evaluated. Preoperative and 3-month-postoperative topographic and corneal wavefront analyses are performed using corneal topography. Ablations are performed using a laser with an aberration-free profile. Topographic changes in asphericity and corneal aberrations are evaluated for a 6-mm corneal diameter. The induction of corneal spherical aberrations and asphericity changes correlates with the achieved defocus correction. Preoperatively as well as postoperatively, asphericity calculated from the topography meridians correlates with asphericity calculated from the corneal wavefront in myopic and hyperopic treatments. A stronger correlation between postoperative asphericity and the ideally expected/predicted asphericity is obtained based on aberration-free assumptions calculated from corneal wavefront values rather than from the meridians. In hyperopic treatments, a better correlation can be obtained compared to the correlation in myopic treatments. Corneal asphericity calculated from corneal wavefront aberrations represents a 3-D fit of the corneal surface; asphericity calculated from the main topographic meridians represents a 2-D fit of the principal corneal meridians. Postoperative corneal asphericity can be calculated from corneal wavefront aberrations with higher fidelity than from corneal topography of the principal meridians. Hyperopic treatments show a greater accuracy than myopic treatments.

  8. Ocular irritation reversibility assessment for personal care products using a porcine corneal culture assay.

    Science.gov (United States)

    Donahue, Douglas A; Avalos, Javier; Kaufman, Lewis E; Simion, F Anthony; Cerven, Daniel R

    2011-04-01

    Personal care product manufacturers have used a broad spectrum of alternative ocular irritation assays during the past two decades because these tests do not require the use of live animals, they provide reliable predictive data, and they are relatively inexpensive to conduct. To complement these assays, the ex vivo Porcine Corneal Opacity Reversibility Assay (PorCORA) was recently developed using a corneal culture model to predict reversibility of ocular irritants. Three commercially available consumer products (a shampoo, a hair color glaze, and a hair colorant system containing 12% hydrogen peroxide) were each tested in two PorCORA study replicates in order to assess potential ocular damage reversibility for surfactant-, propylene carbonate-, and peroxide-based formulations, respectively. Under the exaggerated, in vitro study conditions, the surfactant-based shampoo may cause irreversible porcine corneal damage (histological changes in the epithelial squamous cell and/or basal cell layers), whereas the hair color glaze and 12% hydrogen peroxide product caused fully reversible ocular irritation (microscopic changes only in the superficial squamous cell layer). The hair color glaze and peroxide product results correlate with established in vivo data for similar compounds, but the shampoo results contradicted previous BCOP results (expected to be only a mild irritant). Therefore, although the PorCORA protocol shows promise in predicting the extent and reversibility of potential ocular damage caused by accidental consumer eye exposure to personal care products, the contradictory results for the surfactant-based shampoo indicate that more extensive validation testing of the PorCORA is necessary to definitively establish the protocol's reliability as a Draize test replacement.

  9. 77 FR 13977 - Quality Assurance Requirements for Continuous Opacity Monitoring Systems at Stationary Sources

    Science.gov (United States)

    2012-03-08

    ... AGENCY 40 CFR Part 60 RIN 2060-AH23 Quality Assurance Requirements for Continuous Opacity Monitoring... final rule titled, ``Quality Assurance Requirements for Continuous Opacity Monitoring Systems at... electronically in www.regulations.gov or in hard copy at the Procedure 3--Quality Assurance Requirements for...

  10. 77 FR 8160 - Quality Assurance Requirements for Continuous Opacity Monitoring Systems at Stationary Sources

    Science.gov (United States)

    2012-02-14

    ... AGENCY 40 CFR Part 60 RIN 2060-AH23 Quality Assurance Requirements for Continuous Opacity Monitoring...--Quality Assurance Requirements for Continuous Opacity Monitoring Systems at Stationary Sources Docket, EPA.... Rules establishing quality assurance requirements impose no costs independent from national emission...

  11. 77 FR 18709 - Quality Assurance Requirements for Continuous Opacity Monitoring Systems at Stationary Sources

    Science.gov (United States)

    2012-03-28

    ... AGENCY 40 CFR Part 60 RIN 2060-AH23 Quality Assurance Requirements for Continuous Opacity Monitoring... final rule. SUMMARY: The EPA published a direct final rule titled ``Quality Assurance Requirements for....regulations.gov or in hard copy at the Procedure 3--Quality Assurance Requirements for Continuous Opacity...

  12. 40 CFR Figure 1 to Subpart Qqq of... - Data Summary Sheet for Determination of Average Opacity

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Data Summary Sheet for Determination of.... 63, Subpt. QQQ, Fig. 1 Figure 1 to Subpart QQQ of Part 63—Data Summary Sheet for Determination of Average Opacity Clock time Number of converters blowing Converter aisle activity Average opacity for...

  13. Monocyte development inhibitor PRM-151 decreases corneal myofibroblast generation in rabbits.

    Science.gov (United States)

    Santhiago, M R; Singh, V; Barbosa, F L; Agrawal, V; Wilson, S E

    2011-11-01

    This study investigated whether PRM-151 (Promedior, Inc., Malvern, PA), a recombinant form of human pentraxin-2 (PTX-2, also referred to as serum amyloid P, hSAP), that inhibits differentiation of circulating monocytes into fibrocytes and profibrotic macrophages, could modulate generation of myofibroblasts after opacity-producing corneal injury in rabbits, and, therefore, have potential to reduce or prevent haze after PRK. Nine diopter PRK for myopia was performed with the VISX S4 IR laser. Four groups of 6 animals were treated in masked fashion: Group 1: 30 μl of topical PRM-151 (20 mg/ml) 6 times a day for 5 days; Group 2: 30 μl topical vehicle 6 times a day for 5 days; Group 3: 200 μl sub-conjunctival PRM-151 (total injection of 4 mg) immediately after surgery and every other day until day 8; Group 4: 200 μl sub-conjunctival injections of vehicle according to the same schedule as group 3. At one month after PRK, the animals were euthanized and immunohistochemistry was performed for the myofibroblast marker α-smooth muscle actin (SMA). The density of SMA+ cells/400× field in the central stroma was determined in each cornea. Myofibroblast density at one month after surgery was significantly lower (p = 0.006) after sub-conjunctival PRM-151 treatment (5.8 ± 2.8 cells/400× stromal field) compared to sub-conjunctival vehicle treatment (15.3 ± 2.9 cells/400× stromal field). There was no significant (p = 0.27) decrease in stromal myofibroblasts triggered by topical PRM-151 treatment (11.8 ± 6.6 cells/400× stromal field) compared to the topical vehicle treatment (14.2.8 ± 6.2 cells/400× stromal field). PRM-151 inhibits myofibroblast generation when administered by sub-conjunctival injection, but not when administered topically, after opacity-producing corneal injury. This study provides additional confirmation that bone marrow-derived cells contribute to corneal myofibroblast generation.

  14. Update on pathologic diagnosis of corneal infections and inflammations

    Directory of Open Access Journals (Sweden)

    Geeta K Vemuganti

    2011-01-01

    Full Text Available One of the most frequent types of corneal specimen that we received in our pathology laboratory is an excised corneal tissue following keratoplasty. Several of these cases are due to corneal infections or the sequelae, like corneal scar. Advances in the histological and molecular diagnosis of corneal infections and inflammations have resulted in rapid and accurate diagnosis of the infectious agent and in the overall understanding of the mechanisms in inflammatory diseases of the cornea. This review provides an update of histopathological findings in various corneal infections and inflammations.

  15. Fine-Tuning Two-Particle Interferometry; 2, Opacity Effects

    CERN Document Server

    Tomasik, Boris; Tomasik, Boris; Heinz, Ulrich

    1998-01-01

    We present a model study of single-particle spectra and two-particle Bose-Einstein correlations for opaque sources. We study the transverse mass dependence of the correlation radii R_\\perp, R_\\parallel and R_0 in the YKP parametrization and find a strong sensitivity of the temporal radius parameter R_0^2 to the source opacity. A simple comparison with the published data from 158 A GeV/c Pb+Pb collisions at CERN indicates that the pion source created in these collisions emits particles from the whole reaction volume and is not opaque. For opaque sources we find certain regions of inapplicability of the YKP parametrization which can be avoided by a slightly different parametrization for the correlator. The physical meaning of the modified parameters is briefly discussed.

  16. Galactic cold cores. VI. Dust opacity spectral index

    Science.gov (United States)

    Juvela, M.; Demyk, K.; Doi, Y.; Hughes, A.; Lefèvre, C.; Marshall, D. J.; Meny, C.; Montillaud, J.; Pagani, L.; Paradis, D.; Ristorcelli, I.; Malinen, J.; Montier, L. A.; Paladini, R.; Pelkonen, V.-M.; Rivera-Ingraham, A.

    2015-12-01

    Context. The Galactic Cold Cores project has carried out Herschel photometric observations of 116 fields where the Planck survey has found signs of cold dust emission. The fields contain sources in different environments and different phases of star formation. Previous studies have revealed variations in their dust submillimetre opacity. Aims: The aim is to measure the value of dust opacity spectral index and to understand its variations spatially and with respect to other parameters, such as temperature, column density, and Galactic location. Methods: The dust opacity spectral index β and the dust colour temperature T are derived using Herschel and Planck data. The relation between β and T is examined for the whole sample and inside individual fields. Results: Based on IRAS and Planck data, the fields are characterised by a median colour temperature of 16.1 K and a median opacity spectral index of β = 1.84. The values are not correlated with Galactic longitude. We observe a clear T-β anti-correlation. In Herschel observations, constrained at lower resolution by Planck data, the variations follow the column density structure and βFIR can rise to ~2.2 in individual clumps. The highest values are found in starless clumps. The Planck 217 GHz band shows a systematic excess that is not restricted to cold clumps and is thus consistent with a general flattening of the dust emission spectrum at millimetre wavelengths. When fitted separately below and above 700 μm, the median spectral index values are βFIR ~ 1.91 and β(mm) ~ 1.66. Conclusions: The spectral index changes as a function of column density and wavelength. The comparison of different data sets and the examination of possible error sources show that our results are robust. However, β variations are partly masked by temperature gradients and the changes in the intrinsic grain properties may be even greater. Planck http://www.esa.int/Planck is a project of the European Space Agency - ESA - with instruments

  17. Opacity measurements in shock-generated argon plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Erskine, D.

    1993-07-01

    Dense plasmas having uniform and constant density and temperature are generated by passage of a planar shock wave through gas. The opacity of the plasma is accurately measured versus wavelength by recording the risetime of emitted light. This technique is applicable to a wide variety of species and plasma conditions. Initial experiments in argon have produced plasmas with 2 eV temperatures, 0.004--0.04 g/cm{sup 3} densities, and coupling parameters {Gamma} {approximately}0.3--0.7. Measurements in visible light are compared with calculations using the HOPE code. An interesting peak in the capacity at 400 nm is observed for the first time and is identified with the 4s-5p transition in excited neutral argon atoms.

  18. The hybrid opacity code SCO-RCG: recent developments

    CERN Document Server

    Pain, Jean-Christophe; Porcherot, Quentin; Blenski, Thomas

    2013-01-01

    Absorption and emission spectra of multicharged-ion plasmas contain a huge number of electron configurations and electric-dipolar lines, which can be handled by global methods. However, some transition arrays consist only of a small bunch of lines. For that reason, we developed the hybrid opacity code SCO-RCG combining the (statistical) super-transition-array method and the (detailed) fine-structure calculation (requiring the diagonalization of the Hamiltonian matrix) of atomic structure. In order to decide whether a detailed treatment of lines is necessary and to determine the validity of statistical methods, the code involves criteria taking into account coalescence of lines and porosity (localized absence of lines) in transition arrays. Data required for the calculation of detailed transition arrays (Slater, spin-orbit and dipolar integrals) are provided by the super-configuration code SCO, which takes into account plasma screening effects on wavefunctions. Then, level energies and lines are calculated by ...

  19. Rosseland Mean Opacity of a High-Z Mixture Plasma

    Institute of Scientific and Technical Information of China (English)

    杨家敏; 许琰; 丁耀南; 丁永坤; 江少恩; 郑志坚; 缪文勇

    2003-01-01

    An eight-beam 0.351-μm laser with pulse duration of about 1.0ns and energy of 260 J per beam was injected into a cylindrical cavity to generate intense x-ray radiation on the Shengguang Ⅱ high power laser facility. A mixture foil of gold and gadolinium and a gold foil were attached on portion of a diagnostic hole in the mid-plane of the cavity and ablated by the intense x-ray radiation. The propagating time of the radiation heat wave in the mixture and the pure gold foil were measured with soft-x-ray spectrometer and by adopting space- and timeresolved measurement technology, respectively. The results show that the mixture of gold and gadolinium has higher Rosseland mean opacity than the gold sample in our experiment.

  20. Survival and integration of tissue-engineered corneal stroma in a model of corneal ulcer.

    Science.gov (United States)

    Zhang, Chao; Nie, Xin; Hu, Dan; Liu, Yuan; Deng, Zhihong; Dong, Rui; Zhang, Yongjie; Jin, Yan

    2007-08-01

    Tissue-engineered replacement of diseased or damaged tissue has become a reality for some types of tissue, such as skin and cartilage. Tissue-engineered corneal stroma represents a promising concept to overcome the limitations of cornea replacement with allograft. In this study, porcine cornea was decellularized by a series of extraction methods, and the in vivo biocompatibility of the scaffold was measured subcutaneously in rabbits (n = 8). These were not acutely rejected and no abscesses were observed by hematoxylin and eosin staining at the 8th week, indicating that the scaffolds had good biocompatibility. To investigate the potential value of clinical applications, rabbit stromal keratocytes were implanted onto decellularized scaffolds to fabricate tissue-engineered corneal stroma. Allograft, tissue-engineered corneal stroma, or scaffolds were implanted into a model of corneal ulcer. The survival and reconstruction of corneal transplantation were morphologically evaluated by light and electron microscopy until the 32nd week after implantation. Experiments involving transplantation indicated that the epithelial and stromal defect healed quickly, with improvement in corneal clarity. The integration of the graft was accompanied by neurite ingrowth from the host tissue. By 16 weeks after transplantation, the cornea had gradually regained an intact state similar to that of normal cornea. Our results demonstrate that the tissue-engineered corneal stroma with allogenetic cells is a promising therapeutic method for corneal injury.

  1. Iron Opacity Bump Changes the Stability and Structure of Accretion Disks in Active Galactic Nuclei

    CERN Document Server

    Jiang, Yan-Fei; Stone, James

    2016-01-01

    Accretion disks around supermassive black holes have regions where the Rosseland mean opacity can be much larger than the electron scattering opacity primarily due to the large number of bound-bound transitions in iron. We study the effects of this iron opacity "bump" on the thermal stability and vertical structure of radiation pressure dominated accretion disks, utilizing three dimensional radiation magneto-hydrodynamic simulations in the local shearing box approximation. The simulations self-consistently calculate the heating due to MHD turbulence caused by magneto-rotational instability and radiative cooling by using the radiative transfer module based on a variable Eddington tensor in Athena. For a $5\\times 10^8$ solar mass black hole with $\\sim 3\\%$ of the Eddington luminosity, a model including the iron opacity bump maintains its structure for more than $10$ thermal times without showing significant signs of thermal runaway. In contrast, if only electron scattering and free-free opacity are included as ...

  2. The statistical properties of stars and their dependence on metallicity: the effects of opacity

    CERN Document Server

    Bate, Matthew R

    2014-01-01

    We report the statistical properties of stars and brown dwarfs obtained from four radiation hydrodynamical simulations of star cluster formation that resolve masses down to the opacity limit for fragmentation. The calculations are identical except for their dust and gas opacities. Assuming dust opacity is proportional to metallicity, the calculations span a range of metallicities from 1/100 to 3 times solar, although we emphasise that changing the metallicity has other thermodynamic effects that the calculations do not capture (e.g. on the thermal coupling between gas and dust). All four calculations produce stellar populations whose statistical properties are difficult to distinguish from observed stellar systems, and we find no significant dependence of stellar properties on opacity. The mass functions and properties of multiple stellar systems are consistent with each other. However, we find protostellar mergers are more common with lower opacities. Combining the results from the three calculations with th...

  3. OPACITY MEASUREMENT AND THEORETICAL INVESTIGATION OF HOT SILICON PLASMA

    Energy Technology Data Exchange (ETDEWEB)

    Xiong, Gang; Yang, Jiamin; Zhang, Jiyan; Hu, Zhimin; Zhao, Yang; Qing, Bo; Yang, Guohong; Wei, Minxi; Yi, Rongqing; Song, Tianming; Li, Hang; Yuan, Zheng; Lv, Min [Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900 (China); Meng, Xujun; Xu, Yan; Wu, Zeqing; Yan, Jun, E-mail: zhangjiyanzjy@sina.com, E-mail: zhimin.hu@yahoo.com [Institute of Applied Physics and Computational Mathematics, Beijing 100088 (China)

    2016-01-01

    We report on opacity measurements of a silicon (Si) plasma at a temperature of (72 ± 5) eV and a density of (6.0 ± 1.2) mg cm{sup −3} in the photon energy range of 1790–1880 eV. A 23 μg cm{sup −2} Si foil tamped by 50 μg cm{sup −2} CH layers on each side was heated to a hot-dense plasma state by X-ray radiation emitted from a D-shaped gold cavity that was irradiated by intense lasers. Absorption lines of 1s − 2p transitions of Si xiii to Si ix ions have been measured using point-projection spectroscopy. The transmission spectrum of the silicon plasma was determined by comparing the light passing through the plasma to the light from the same shot passing by the plasma. The density of the Si plasma was determined experimentally by side-on radiography and the temperature was estimated from the radiation flux data. Radiative hydrodynamic simulations were performed to obtain the temporal evolutions of the density and temperature of the Si plasma. The experimentally obtained transmission spectra of the Si sample plasma have been reproduced using a detailed term account model with the local thermodynamic equilibrium approximation. The energy levels, oscillator strengths and photoionization cross-sections used in the calculation were generated by the flexible atomic code. The experimental transmission spectrum was compared with the theoretical calculation and good agreement was found. The present experimental spectrum and theoretical calculation were also compared with the new opacities available in the Los Alamos OPLIB database.

  4. Ultrasound biomicroscopy confirmation of corneal overriding due to improper suturing of full-thickness corneal laceration

    Directory of Open Access Journals (Sweden)

    Murat Kucukevcilioglu

    2014-12-01

    Full Text Available We herein present a case with corneal overriding due to improper suturing of a full-thickness corneal laceration. There was a 2.5-mm difference between horizontal and vertical white-to-white measurements in the cornea. However, slit lamp examination failed to demonstrate the exact architecture of the laceration. Ultrasound biomicroscopy defined the wound edges thoroughly and confirmed the presence of corneal overriding. Six weeks after suture enhancement, the abnormal oval appearance of the cornea was absent and correct apposition of the corneal edges was seen on ultrasound biomicroscopy. Ultrasound biomicroscopy can be used in preoperative surgical planning of cases with complicated corneal lacerations. It can be used to adjust and enhance wound architecture in eyes with penetrating injury.

  5. Measurements of the 492 GHz Atmospheric Opacity at Pampa la Bola and Rio Frio in Northern Chile

    Science.gov (United States)

    Hirota, Tomoya; Yamamoto, Satoshi; Sekimoto, Yutaro; Kohno, Kotaro; Nakai, Naomasa; Kawabe, Ryohei

    1998-02-01

    We have developed a transportable 492 GHz tipping radiometer to measure the atmospheric opacity at potential sites for future ground-based astronomical observations in the submillimeter-wave band. With this radiometer, we measured the atmospheric opacity at two sites in northern Chile, Pampa la Bola (elevation 4800 m) and Rio Frio (elevation 4100 m), each for a few days. The 492 GHz opacity mostly ranged from 0.5 to 1.5 during the measurements. The 220 GHz opacity was also measured at the same time. The 492 GHz opacity correlates well with the 220 GHz opacity, the ratio between the 492 and 220 GHz opacities being 21.2 +/- 0.4. This result supports the standard atmospheric model, and can be used to evaluate the observable fraction of time for submillimeter-wave observations on the basis of the long-term 220 GHz opacity data. } %

  6. 3.5 Year Monitoring of 225 GHz Opacity at the Summit of Greenland

    Science.gov (United States)

    Matsushita, Satoki; Asada, Keiichi; Martin-Cocher, Pierre L.; Chen, Ming-Tang; Ho, Paul T. P.; Inoue, Makoto; Koch, Patrick M.; Paine, Scott N.; Turner, David D.

    2017-02-01

    We present the 3.5 years monitoring results of 225 GHz opacity at the summit of the Greenland ice sheet (Greenland Summit Camp) at an altitude of 3200 m using a tipping radiometer. We chose this site as our submillimeter telescope (Greenland Telescope) site, because conditions are expected to have low submillimeter opacity and because its location offers favorable baselines to existing submillimeter telescopes for global-scale Very Long Baseline Interferometry. The site shows a clear seasonal variation with the average opacity lower by a factor of two during winter. The 25%, 50%, and 75% quartiles of the 225 GHz opacity during the winter months of November through April are 0.046, 0.060, and 0.080, respectively. For the winter quartiles of 25% and 50%, the Greenland site is about 10%-30% worse than the Atacama Large Millimeter/submillimeter Array (ALMA) or the South Pole sites. Estimated atmospheric transmission spectra in winter season are similar to the ALMA site at lower frequencies (\\lt 450 GHz), which are transparent enough to perform astronomical observations almost all of the winter time with opacities \\lt 0.5, but 10%-25% higher opacities at higher frequencies (\\gt 450 GHz) than those at the ALMA site. This is due to the lower altitude of the Greenland site and the resulting higher line wing opacity from pressure-broadened saturated water lines in addition to higher dry air continuum absorption at higher frequencies. Nevertheless, half of the winter time at the Greenland Summit Camp can be used for astronomical observations at frequencies between 450 GHz and 1000 GHz with opacities \\lt 1.2, and 10% of the time show \\gt 10 % transmittance in the THz (1035 GHz, 1350 GHz, and 1500 GHz) windows. Summer season is good for observations at frequencies lower than 380 GHz. One major advantage of the Greenland Summit Camp site in winter is that there is no diurnal variation due to the polar night condition, and therefore the durations of low-opacity conditions

  7. Changes on the corneal thickness and curvature after orthokeratology

    Science.gov (United States)

    Mitsui, Iwane; Yamada, Yoshiya

    2004-07-01

    To evaluate the corneal thickness and curvature changes after Orthokeratology contact lens wear, using the ORBSCAN II corneal topography system, corneal thickness and corneal curvature were measured on one hundred and twenty eyes of sixty patients before and after wearing the custom rigid gas permeable contact lenses for Orthokeratology. The contact lenses were specially designed for each eye. The subjects wore the orthokeratology lenses for approximately Four hours with their eyes closed. The corneal thickness of the subjects was increased on fifty-five eyes at not only the peripheral zone but also the center of the cornea. The average increase of central and peripheral corneal thickness was 18 micrometer and 22micrometer, respectively. The mean anterior curvature of corneal surface changed 1.25D. The mean posterior curvature of corneal endothelium side changed 0.75D.

  8. Acute Corneal Hydrops 3 Years after Intra-corneal Ring Segments and Corneal Collagen Cross-linking

    Science.gov (United States)

    Antonios, Rafic; Dirani, Ali; Fadlallah, Ali; Chelala, Elias; Hamadeh, Adib; Jarade, Elias

    2016-01-01

    This case report describes a 15-year-old male with allergic conjunctivitis and keratoconus, who underwent uneventful intra-corneal ring segment (ICRS) implantation and corneal collagen cross-linking (CXL) in the right eye. During the follow-up periods, the patient was noted to have several episodes of allergic conjunctivitis that were treated accordingly. At the 2 years postoperatively, he presented with another episode of allergic conjunctivitis and progression of keratoconus was suspected on topography. However, the patient was lost to follow-up, until he presented with acute hydrops at 3 years postoperatively. There are no reported cases of acute corneal hydrops in cross-linked corneas. We suspect the young age, allergic conjunctivitis and eye rubbing may be a risk factors associated with possible progression of keratoconus after CXL. Prolonged follow-up and aggressive control of the allergy might be necessary in similar cases. PMID:26957859

  9. [Representation and mathematical analysis of human corneal surface].

    Science.gov (United States)

    Tălu, Stefan; Tălu, Mihai; Giovanzana, Stefano

    2011-01-01

    In the description and analysis of human corneal surface are used various mathematical models based on parametric representations, used in biomechanical studies and 3D solid modeling of the cornea. Mathematical models are important into the biomechanics of the cornea to model the corneal behavior. Corneal biomechanics also has the potential to improve outcomes in refractive surgery. The objective of this paper is to present the most representative mathematical models currently used for modeling of human corneal in optics and biomechanics fields.

  10. Contact lens rehabilitation following repaired corneal perforations

    Directory of Open Access Journals (Sweden)

    Sreenivas V

    2006-03-01

    Full Text Available Abstract Background Visual outcome following repair of post-traumatic corneal perforation may not be optimal due to presence of irregular keratometric astigmatism. We performed a study to evaluate and compare rigid gas permeable contact lens and spectacles in visual rehabilitation following perforating corneal injuries. Method Eyes that had undergone repair for corneal perforating injuries with or without lens aspiration were fitted rigid gas permeable contact lenses. The fitting pattern and the improvement in visual acuity by contact lens over spectacle correction were noted. Results Forty eyes of 40 patients that had undergone surgical repair of posttraumatic corneal perforations were fitted rigid gas permeable contact lenses for visual rehabilitation. Twenty-four eyes (60% required aphakic contact lenses. The best corrected visual acuity (BCVA of ≥ 6/18 in the snellen's acuity chart was seen in 10 (25% eyes with spectacle correction and 37 (92.5% eyes with the use of contact lens (p Conclusion Rigid gas permeable contact lenses are better means of rehabilitation in eyes that have an irregular cornea due to scars caused by perforating corneal injuries.

  11. Corneal Phaeohyphomycosis Caused by Bipolaris hawaiiensis

    Directory of Open Access Journals (Sweden)

    Winai Chaidaroon

    2016-07-01

    Full Text Available Purpose: To report a rare case of keratitis infected by Bipolaris hawaiiensis. Methods: A patient who was diagnosed as fungal keratitis caused by B. hawaiiensis was retrospectively reviewed for history, clinical characteristics, risk factors, laboratory findings, treatments, and outcomes. Results: A 63-year-old man with a history of trauma and saw dust in the left eye presented with a corneal ulcer. Eye examination revealed whitish infiltration with a feathery edge and small brownish deposits in the anterior stroma of the left cornea. Numerous septate hyphal fragments were detected in a corneal specimen, and nucleotide sequence analysis identified B. hawaiiensis. Treatment was started with 5% natamycin eyedrops and oral itraconazole. Subsequently, a corneal plaque developed which did not respond to medication and debridement. The patient underwent therapeutic penetrating keratoplasty. Conclusions: B. hawaiiensis is a rare cause of corneal phaeohyphomycosis. A brownish pigmented infiltration is an important diagnostic clue, however microbiologic studies are required to obtain a definite diagnosis. Although antifungal medication and debridement are the mainstay of most corneal fungal infection, therapeutic penetrating keratoplasty can prevent morbidity related to this fungal infection.

  12. Corneal Phaeohyphomycosis Caused by Bipolaris hawaiiensis

    Science.gov (United States)

    Chaidaroon, Winai; Supalaset, Sumet; Tananuvat, Napaporn; Vanittanakom, Nongnuch

    2016-01-01

    Purpose To report a rare case of keratitis infected by Bipolaris hawaiiensis. Methods A patient who was diagnosed as fungal keratitis caused by B. hawaiiensis was retrospectively reviewed for history, clinical characteristics, risk factors, laboratory findings, treatments, and outcomes. Results A 63-year-old man with a history of trauma and saw dust in the left eye presented with a corneal ulcer. Eye examination revealed whitish infiltration with a feathery edge and small brownish deposits in the anterior stroma of the left cornea. Numerous septate hyphal fragments were detected in a corneal specimen, and nucleotide sequence analysis identified B. hawaiiensis. Treatment was started with 5% natamycin eyedrops and oral itraconazole. Subsequently, a corneal plaque developed which did not respond to medication and debridement. The patient underwent therapeutic penetrating keratoplasty. Conclusions B. hawaiiensis is a rare cause of corneal phaeohyphomycosis. A brownish pigmented infiltration is an important diagnostic clue, however microbiologic studies are required to obtain a definite diagnosis. Although antifungal medication and debridement are the mainstay of most corneal fungal infection, therapeutic penetrating keratoplasty can prevent morbidity related to this fungal infection. PMID:27721785

  13. Corneal trephination with the femtosecond laser.

    Science.gov (United States)

    Meltendorf, Christian; Schroeter, Jan; Bug, Reinhold; Kohnen, Thomas; Deller, Thomas

    2006-10-01

    To evaluate the feasibility and cut quality of corneal trephination in human donor corneal tissue with the femtosecond laser. Twelve human corneoscleral discs were inserted in an artificial anterior chamber. After corneal thickness measurement and tonometry, the cornea was mounted on a femtosecond laser (FEMTEC; 20/10 Perfect Vision, Heidelberg, Germany) through a contact lens (patient interface). Trephination was performed with diameters of 7.0, 7.5, 8.0, and 8.5 mm in 3 corneas each. The corneal button was removed from the corneoscleral disc in 2 of the 3 corneas in each case. The cut was not manipulated in the remaining corneas to enable histologic detection of possible tissue bridges. The cut edges were macroscopically and light-microscopically examined for quality. Corneal buttons and corneoscleral discs could be separated by blunt dissection in all cases. Tissue bridges were more common in thicker edematous corneas than in thinner ones. Both the macro- and microscopic examination disclosed smooth rectilinear cut margins with a perpendicular cut edge. This feasibility study shows that the femtosecond laser enables sufficient trephination of human donor corneas.

  14. Corneal reconstruction by stem cells and bioengineering

    Directory of Open Access Journals (Sweden)

    Arjamaa O

    2012-09-01

    Full Text Available Olli ArjamaaDepartment of Biology, University of Turku, Turku, FinlandAbstract: Almost 300 million people are visually impaired worldwide due to various eye diseases such as cataracts, glaucoma, age-related macular degeneration, diabetic retinopathy, and corneal diseases. Notably, ten million people are blind because of severe ocular surface diseases and the majority of cases occur in developing countries. Blinding ocular surface diseases have, however, become treatable by grafting of surface layers, or by full-thickness transplantation of the cornea. As the demand for human corneal tissue for surface reconstruction and transplantation far exceeds the supply, methods are being developed to supplement tissue donation. Xenotransplantation of the cornea or cells from genetically modified pigs may become one of the solutions. Transplantation of limbal stem cells within tissue biopsies, to restore the transparency of the cornea is another remarkable method, which has shown its potential in several clinical studies. The combination of stem cell technology and engineering of biocompatible tissue equivalent, still at preclinical stage, has shown us how synthetic corneal tissue is able to guide cultured corneal stromal stem cells of human origin, to become native-like stroma, the most important layer of the cornea. These findings give hope for a large-quantity production of biomaterial for corneal reconstruction. As such, clinical ophthalmologists should become more familiar with the methods of laboratory science.Keywords: eye, grafting, keratoplasty, xenotransplantation, cell reservoir, biocompatible tissue equivalent

  15. The impact of enhanced iron opacity on massive star pulsations: updated instability strips

    Science.gov (United States)

    Moravveji, Ehsan

    2016-01-01

    Recently, Bailey et al. made a direct measurement of the iron opacity at the physical conditions of the solar tachocline. They found that the wavelength-integrated iron opacity is roughly 75 per cent higher than what the Opacity Project (OP) and OPAL models predict. Here, we compute new opacity tables with enhanced iron and nickel contributions to the Rosseland mean opacity by 75 per cent each, and compute three dense MESA grids of evolutionary models for Galactic O- and B-type stars covering from 2.5 to 25 M⊙ from zero-age main sequence (ZAMS) until Teff = 10 000 K after the core hydrogen exhaustion. We carry out non-adiabatic mode stability analysis with GYRE, and update the extension of the instability strips of heat-driven p- and g-mode pulsators, and the hybrid slowly pulsating B (SPB) - β Cep stars. We compare the position of two confirmed late O-type β Cep and eight confirmed hybrid B-type pulsators with the new instability domains, and justify that ˜75 per cent enhancement, only in iron opacity, is sufficient to consistently reproduce the observed position of these stars on the log Teff versus log g plane. We propose that this improvement in opacities be incorporated in the input physics of new stellar models.

  16. Detailed investigations on radiative opacity and emissivity of tin plasmas in the extreme-ultraviolet region.

    Science.gov (United States)

    Zeng, Jiaolong; Gao, Cheng; Yuan, Jianmin

    2010-08-01

    Radiative opacity and emissivity of tin plasmas at average ionization degree of about 10 was investigated in detail by using a fully relativistic detailed level accounting approach, in which main physical effects on the opacity were carefully taken into account. Among these physical effects, configuration interaction, in particular core-valence electron correlations, plays an important role on the determination of accurate atomic data required in the calculation of opacity. It results in a strong narrowing of lines from all transition arrays and strong absorption is located in a narrow wavelength region of 12.5-14 nm for Sn plasmas. Using a complete accurate atomic data, we investigated the opacity of Sn plasmas at a variety of physical condition. Among the respective ions of Xe6+-Xe15+ , Xe10+ has the largest absorption cross section at 13.5 nm, while the favorable physical condition for maximal absorption at 13.5 nm do not mean that Xe10+ has the largest fraction. Comparison with other theoretical results showed that a complete set of consistent accurate atomic data, which lacks very much, is essential to predict accurate opacity. Our atomic model is useful and can be applied to interpret opacity experiments. Further benchmark experiments are urgently needed to clarify the physical effects on the opacity of Sn plasmas.

  17. Using xRage to Model Heat Flow for Experiments to Measure Opacities in HED Plasmas

    Science.gov (United States)

    Elgin, L.; Vandervort, R.; Keiter, P.; Drake, R. P.; Mussack, K.; Orban, C.

    2015-11-01

    We are developing a NIF proposal to measure opacities of C, N and O at temperatures and densities relevant to the base of the solar convection zone. Our proposed experiments would provide the first opacity measurements for these elements within this HED regime. A critical feature of our experimental platform is a super-sonic radiation front propagating within the targets. Under these conditions, density remains constant across the radiation front for a couple nanoseconds, enabling a window during which the opacities of the hot and cold target may be measured simultaneously. Afterwards, hydrodynamic effects create temperature and density gradients, which would obfuscate analysis of opacity data. We are using xRage to simulate heat flow within our targets in order to estimate the time scale over which temperature and density gradients evolve. These simulations will better inform our target design and diagnostic requirements. If successful, our experiments could yield the data necessary to validate existing opacity models or provide physical insights to inform the development of new opacity models. Accurate opacity models are essential to the understanding of radiation transport within HED systems, with applications ranging from astrophysics to ICF. U.S. Department of Energy, through the NNSA-DS and SC-OFES Joint Program in High-Energy-Density Laboratory Plasmas, grant #DE-NA0001840. Los Alamos National Laboratory, LA-UR-15-25490.

  18. Analysis of the horizontal corneal diameter, central corneal thickness, and axial length in premature infants

    Directory of Open Access Journals (Sweden)

    Ozdemir Ozdemir

    2014-08-01

    Full Text Available Purpose: To determine the horizontal corneal diameter, central corneal thickness, and axial length in premature infants. Methods: Infants with a birth weight of less than 2,500 g or with a gestation period of less than 36 weeks were included in the study. Infants with retinopathy of prematurity (ROP were allocated to Group 1 (n=138, while those without ROP were allocated to Group 2 (n=236. All infants underwent a complete ophthalmologic examination, including corneal diameter measurements, pachymetry, biometry, and fundoscopy. Between-group comparisons of horizontal corneal diameter, central corneal thickness, and axial lengths were performed. Independent sample t-tests were used for statistical analysis. Results: Data was obtained from 374 eyes of 187 infants (102 female, 85 male. The mean gestational age at birth was 30.7 ± 2.7 weeks (range 25-36 weeks, the mean birth weight was 1,514 ± 533.3 g (range 750-1,970 g, and the mean postmenstrual age at examination was 40.0 ± 4.8 weeks. The mean gestational age and the mean birth weight of Group 1 were statistically lower than Group 2 (p0.05. Conclusions: The presence of ROP in premature infants does not alter the horizontal corneal diameter, central corneal thickness, or axial length.

  19. 21 CFR 886.1450 - Corneal radius measuring device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Corneal radius measuring device. 886.1450 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1450 Corneal radius measuring device. (a) Identification. A corneal radius measuring device is an AC-powered device intended to...

  20. Systematic measurements of opacity dependence on temperature, density, and atomic number at stellar interior conditions

    Science.gov (United States)

    Bailey, James; Nagayama, T.; Loisel, G. P.; Rochau, G. A.; Blancard, C.; Colgan, J.; Cosse, Ph.; Faussurier, G.; Fontes, C. J.; Golovkin, I.; Hansen, S. B.; Iglesias, C. A.; Kilcrease, D. P.; Macfarlane, J. J.; Mancini, R. C.; Nahar, S. N.; Orban, C.; Pradhan, A. K.; Sherrill, M.; Wilson, B. G.; Pain, J. C.; Gilleron, F.

    2016-10-01

    Model predictions for iron opacity are notably different from measurements performed at conditions similar to the boundary between the solar radiation and convection zone. New measurements at the Sandia Z facility with chromium, iron, and nickel are providing a systematic study of how opacity changes with temperature, density, and atomic number. These measurements help further evaluate possibilities for experiment errors and help constrain hypotheses for opacity model refinements. Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy under contract DE-AC04-94AL85000.

  1. Theoretical Study of the Opacity for Mixture Materials at High Temperatures

    Institute of Scientific and Technical Information of China (English)

    颜君; 吴泽清; 逄锦桥; 邱玉波

    2002-01-01

    Using a detailed configuration accounting model with term structures treated by the unresolved transition array model, we have extensively investigated the opacities of mixt ure materials. For plasmas at the temperat ure of 250eV and density of 1 g/cm3, our calculated Rosseland mean opacities are in good agreement with other theoretical results. A high increase in the Rosseland mean opacity to 2944 cm2/g is achieved for a multi-element mixture compared to the value of 1729 cm2/g for pure gold. Various mixtures at other plasma conditions are also studied.

  2. Corneal nerve microstructure in Parkinson's disease.

    Science.gov (United States)

    Misra, Stuti L; Kersten, Hannah M; Roxburgh, Richard H; Danesh-Meyer, Helen V; McGhee, Charles N J

    2017-03-03

    Ocular surface changes and blink abnormalities are well-established in Parkinson's disease. Blink rate may be influenced by corneal sub-basal nerve density, however, this relationship has not yet been investigated in Parkinson's disease. This case-control study examined the ocular surface in patients with moderately severe Parkinson's disease, including confocal microscopy of the cornea. Fifteen patients with moderately severe Parkinson's disease (modified Hoehn and Yahr grade 3 or 4) and fifteen control participants were recruited. Ophthalmic assessment included slit-lamp examination, blink rate assessment, central corneal aesthesiometry and in vivo corneal confocal microscopy. The effect of disease laterality was also investigated. Of the 15 patients with Parkinson's disease, ten were male and the mean age was 65.5±8.6years. The corneal sub-basal nerve plexus density was markedly reduced in patients with Parkinson's disease (7.56±2.4mm/mm(2)) compared with controls (15.91±2.6mm/mm(2)) (pParkinson's disease (0.79±1.2mBAR) and the control group (0.26±0.35mBAR), p=0.12. Sub-basal nerve density was not significantly different between the eye ipsilateral to the side of the body with most-severe motor symptoms, and the contralateral eye. There was a significant positive correlation between ACE-R scores and sub-basal corneal nerve density (R(2)=0.66, p=0.02). This is the first study to report a significant reduction in corneal sub-basal nerve density in Parkinson's disease and demonstrate an association with cognitive dysfunction. These results provide further evidence to support the involvement of the peripheral nervous system in Parkinson's disease, previously thought to be a central nervous system disorder.

  3. Normal corneal endothelial cell density in Nigerians

    Directory of Open Access Journals (Sweden)

    Ewete T

    2016-03-01

    Full Text Available Temitope Ewete,1 Efeoghene Uchenna Ani,2 Adegboyega Sunday Alabi1 1MeCure Eye Center, Lagos, 2Department of Ophthalmology, University of Port Harcourt, Port Harcourt, Nigeria Aim: The aim of the study was to describe the corneal endothelial cell density of adults at the MeCure Eye Center and to determine the relationship between age, sex, and corneal endothelial cell density. Methods: This study was a retrospective study looking at those records of individuals who had undergone specular microscopy or corneal endothelial cell count measurement at the MeCure Eye Center. Results: The endothelial cell characteristics of 359 healthy eyes of 201 volunteers were studied. The mean corneal endothelial cell density (MCD was 2,610.26±371.87 cells/mm2 (range, 1,484–3,571 cells/mm2. The MCD decreased from 2,860.70 cells/mm2 in the 20–30-year age group to 2,493.06 cells/mm2 in the >70-year age group, and there was a statistically significant relationship between age and MCD with a P-value of <0.001. There was no statistically significant correlation between sex and corneal endothelial cell density (P=0.45. Conclusion: This study shows that endothelial cell density in Nigerian eyes is less than that reported in the Japanese, American, and Chinese eyes, and is comparable to that seen in Indian and Malaysian eyes. Keywords: corneal, endothelial cell density, Nigerian

  4. Mixed quotation: The grammar of apparently transparent opacity

    Directory of Open Access Journals (Sweden)

    Emar Maier

    2014-05-01

    Full Text Available The phenomenon of mixed quotation exhibits clear signs of both the apparent transparency of compositional language use and the opacity of pure quotation. I argue that the interpretation of a mixed quotation in- volves the resolution of a metalinguistic presupposition. The leading idea behind my proposal is that a mixed-quoted expression, say, “has an anomalous feature”, means what x referred to with the words ‘has an anomalous feature’. To understand how this solves the paradox, I set up a precise grammatical framework, explicitly connecting various levels of linguistic analysis: phonological forms, categorial syntax, and a dynamic picture of the semantics–pragmatics interface. In this framework I formalize and evaluate a presuppositional account of mixed quotation. Finally, I address the phenomenon of unquotation and argue that it is an essential ingredient for an elegant and empirically adequate analysis of mixed quotation in natural language. http://dx.doi.org/10.3765/sp.7.7 BibTeX info

  5. Corneal collagen crosslinking for keratoconus. A review

    Directory of Open Access Journals (Sweden)

    M. M. Bikbov

    2014-10-01

    Full Text Available Photochemical crosslinking is widely applied in ophthalmology. Its biochemical effect is due to the release of singlet oxygen that promotes anaerobic photochemical reaction. Keratoconus is one of the most common corneal ectasia affecting 1 in 250 to 250 000 persons. Currently, the rate of iatrogenic ectasia following eximer laser refractive surgery increases due to biomechanical weakening of the cornea. Morphologically and biochemically, ectasia is characterized by corneal layers thinning, contact between the stroma and epithelium resulting from Bowman’s membrane rupture, chromatin fragmentation in keratocyte nuclei, phagocytosis, abnormal staining and arrangement of collagen fibers, enzyme system disorders, and keratocyte apoptosis. In corneal ectasia, altered enzymatic processes result in the synthesis of abnormal collagen. Collagen packing is determined by the activity of various extracellular matrix enzymes which bind amines and aldehydes of collagen fiber amino acids. In the late stage, morphological changes of Descemet’s membrane (i.e., rupture and detachment develop. Abnormal hexagonal-shaped keratocytes and their apoptosis are the signs of endothelial dystrophy. The lack of analogs in domestic ophthalmology encouraged the scientists of Ufa Eye Research Institute to develop a device for corneal collagen crosslinking. The parameters of ultraviolet (i.e., wavelength, exposure time, power to achieve the desired effect were identified. The specifics of some photosensitizers in the course of the procedure were studied. UFalink, a device for UV irradiation of cornea, and photosensitizer Dextralink were developed and adopted. Due to the high risk of endothelial damage, this treatment is contraindicated in severe keratoconus (CCT less than 400 microns. Major effects of corneal collagen crosslinking are the following: Young’s modulus (modulus of elasticity increase by 328.9 % (on average, temperature tolerance increase by 5

  6. Corneal collagen crosslinking for keratoconus. A review

    Directory of Open Access Journals (Sweden)

    M. M. Bikbov

    2014-01-01

    Full Text Available Photochemical crosslinking is widely applied in ophthalmology. Its biochemical effect is due to the release of singlet oxygen that promotes anaerobic photochemical reaction. Keratoconus is one of the most common corneal ectasia affecting 1 in 250 to 250 000 persons. Currently, the rate of iatrogenic ectasia following eximer laser refractive surgery increases due to biomechanical weakening of the cornea. Morphologically and biochemically, ectasia is characterized by corneal layers thinning, contact between the stroma and epithelium resulting from Bowman’s membrane rupture, chromatin fragmentation in keratocyte nuclei, phagocytosis, abnormal staining and arrangement of collagen fibers, enzyme system disorders, and keratocyte apoptosis. In corneal ectasia, altered enzymatic processes result in the synthesis of abnormal collagen. Collagen packing is determined by the activity of various extracellular matrix enzymes which bind amines and aldehydes of collagen fiber amino acids. In the late stage, morphological changes of Descemet’s membrane (i.e., rupture and detachment develop. Abnormal hexagonal-shaped keratocytes and their apoptosis are the signs of endothelial dystrophy. The lack of analogs in domestic ophthalmology encouraged the scientists of Ufa Eye Research Institute to develop a device for corneal collagen crosslinking. The parameters of ultraviolet (i.e., wavelength, exposure time, power to achieve the desired effect were identified. The specifics of some photosensitizers in the course of the procedure were studied. UFalink, a device for UV irradiation of cornea, and photosensitizer Dextralink were developed and adopted. Due to the high risk of endothelial damage, this treatment is contraindicated in severe keratoconus (CCT less than 400 microns. Major effects of corneal collagen crosslinking are the following: Young’s modulus (modulus of elasticity increase by 328.9 % (on average, temperature tolerance increase by 5

  7. Corneal Topographic Analysis in Patients with Cataract

    Institute of Scientific and Technical Information of China (English)

    1994-01-01

    We studied the corneal curvature of 161 eyes in 101 patients, aged from 50 to 80 years (mean: 63 years), with senile cataract using the Topographic Modeling System (IMS) preoperatively. The results revealed that mean surface asymmetry index (SAD was 0. 36 and mean surface regularity index (SRI) 0. 79. Simulated keratometry reading (Sim K) was 44. 46 D, and 43. 56 D. Minimun K reading was 42. 60 D. The same patterns of corneal topography in both eyes were 50% in 60 patients who had binocular examination....

  8. Bessel Function Model for Corneal Topography

    CERN Document Server

    Okrasiński, Wojciech

    2011-01-01

    In this paper we consider a new nonlinear mathematical model for corneal topography formulated as two-point boudary value problem. We derive it from first physical principles and provide some mathematical analysis. The existence and uniqeness theorems are proved as well as various estimates on exact solution. At the end we fit the simplified model based on Modified Bessel Function of the First Kind with the real corneal data consisting of matrix of 123x123 points and obtain an error of order of 1%.

  9. Colletotrichum graminicola: a new corneal pathogen.

    Science.gov (United States)

    Ritterband, D C; Shah, M; Seedor, J A

    1997-05-01

    We report the first case of an ocular infection with the fungus Colletotrichum graminicola causing keratitis in a 27-year-old man. Twenty-four months after a postoperative course complicated by recurrent fungal keratitis requiring two penetrating keratoplasties, two anterior chamber washouts, a conjunctival flap, and medical treatment with topical natamycin, intracameral amphotericin B, and oral fluconazole. The patient has shown no signs of fungal recurrence despite a failed corneal graft. C. graminicola is a new corneal pathogen and should be included in the differential diagnosis of mycotic keratitis.

  10. Research on inhibition of corneal neovascularization

    Directory of Open Access Journals (Sweden)

    Zhang-Hui Yang

    2015-12-01

    Full Text Available Corneal transparency is the basis of the normal physiological functions.However, corneal neovascularization(CNVmay occur in the infection, mechanical and chemical injury or under other pathological conditions,which make the cornea lose original transparency and severe visual impairment. In recent years, along with the development of immunology, molecular biology, biochemistry and other disciplines, there is more in-depth understanding on the CNV, and clinical treatment of CNV has made new breakthroughs. This article provides an overview of the inhibition of CNV.

  11. Granular Corneal Dystrophy Manifesting after Radial Keratotomy

    Directory of Open Access Journals (Sweden)

    Sepehr Feizi

    2008-12-01

    Full Text Available

    PURPOSE: To report manifestation of granular corneal dystrophy after radial keratotomy (RK. CASE REPORT: A 32-year-old man presented with white radial lines in both corneas. He had undergone uncomplicated RK in both eyes 8 years ago. Preoperative refraction had been OD: -3.5 -0.75@180 and OS: -3.0 -0.5@175. Uncorrected visual acuity was OD: 8/10 and OS: 7/10; best corrected visual acuity was 9/10 in both eyes with OD: -0.5 -0.5@60 and OS: -0.75 -0.5@80. Slit lamp examination revealed discrete well-demarcated whitish lesions with clear intervening stroma in the central anterior cornea consistent with granular dystrophy. Similar opacities were present within the RK incisions. CONCLUSION: Granular dystrophy deposits may appear within RK incisions besides other previously reported locations.

  1. Computational Design of Short Pulse Laser Driven Iron Opacity Measurements at Stellar-Relevant Conditions

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Madison E. [Univ. of Florida, Gainesville, FL (United States)

    2017-05-20

    Opacity is a critical parameter in the simulation of radiation transport in systems such as inertial con nement fusion capsules and stars. The resolution of current disagreements between solar models and helioseismological observations would bene t from experimental validation of theoretical opacity models. Overall, short pulse laser heated iron experiments reaching stellar-relevant conditions have been designed with consideration of minimizing tamper emission and optical depth effects while meeting plasma condition and x-ray emission goals.

  2. Purification and partial characterization of the opacity-associated proteins of Neisseria gonorrhoeae

    OpenAIRE

    1984-01-01

    Gonococci, grown on agar, frequently give rise to opaque colonies. This opacity phenotype is associated with the presence of one or more outer membrane proteins of approximately 28,000 mol weight. These proteins are included within a class of proteins named proteins II. A method is described to isolate and purify the opacity-associated proteins from Neisseria gonorrhoeae. This method uses high concentrations of calcium and a zwitterionic detergent at pH 4.0. Under these conditions proteins II...

  3. The relationship between central corneal thickness and corneal curvature in adult Nigerians

    Directory of Open Access Journals (Sweden)

    E. Iyamu

    2011-12-01

    Full Text Available Purpose: The aim of this study was to provide average values for central corneal thickness (CCT and corneal curvature (CC and also to determine a regression model for the relationship between CCT and CC in adult Nigerians without glaucoma.Methods: A total of 95 subjects consisting of 56 males and 39 females aged between 20 and 69 years with mean age of 47.1 ± 14.1 years were recruited for the study. Central corneal thickness was measured by ultrasound pachymetry (SW-1000P ultrasound pachymeter, Tianjin Suowei Electronic Technology, China and corneal curvature was measured by keratometry (Bausch & Lomb keratometer H-135A, USA.Results: The average values of 550.1 ± 33.1µm and 43.0 ± 1.1 D were obtained for CCT and CC respectively. CCT significantly correlated with age (p=0.01, and the regression model predicts a decrease of 6.0 µm in CCT per decade. No significant association was found between CC and age (p=0.56. Also, no significant association was found between CCT and CC (p=0.07. Female subjects had significantly steeper corneas than their male counterparts.Conclusion: Central corneal thickness decreases with increasing age. Neither CCT nor age appear to be significantly correlated with corneal curvature. (S Afr Optom 2011 70(1 44-50

  4. CORNEAL STROMAL THINNING: A RARE CORNEAL COMPLICATION AFTER BARE SCL ERA PTERYG I UM EXCISION TECHNIQUE

    Directory of Open Access Journals (Sweden)

    Sulaiman Abdul

    2015-06-01

    Full Text Available INTRODUCTION : Bare sclera technique without using any anti - mitotic drugs are commonly employed in rural population. Corneal dellen formation and recurrence of pterygium are more common in these cases. But the corneal complication like stromal thinning, necrosis of corne a and sclera are not common. The corneal epithelium is a highly differentiated cell type that is self - renewing. Also corneal epithelium is important for the stromal replacement in the situations like chemical, thermal burns, ocular surgery like pterygium s urgery. Interference with status of stem cell replacement and as a consequent to it, stromal thinning is occurring in the pterygium surgery. P atient 1: A 68 yr s. old male patient underwent pterygium surgery ( B aresclera excision technique. After 30 days he developed corneal thinning with the punched out partial stromal loss without perforation or descmetocele or scleral thinning. Patient 2: A 60yr s. old male patient underwent pterygium surgery 2months back, he developed same type of corneal thinning. Both P atients were treated with tear drops and improved. CONCLUSION : The stromal thinning in these two cases is may be due to chemical factors like collagenase which might have been released from the traumatised conjunctival epithelial cells causing thinning wit hout replacement of stroma by limbal stem cells.

  5. Quantitative proteomic analysis of mice corneal tissues reveals angiogenesis-related proteins involved in corneal neovascularization.

    Science.gov (United States)

    Shen, Minqian; Tao, Yimin; Feng, Yifan; Liu, Xing; Yuan, Fei; Zhou, Hu

    2016-07-01

    Corneal neovascularization (CNV) was induced in Balb/c mice by alkali burns in the central area of the cornea with a diameter of 2.5mm. After fourteen days, the cornea from one eye was collected for histological staining for CNV examination, while the cornea from the other eye of the same mouse was harvested for proteomic analysis. The label-free quantitative proteomic approach was applied to analyze five normal corneal tissues (normal group mice n=5) and five corresponding neovascularized corneal tissues (model group mice n=5). A total of 2124 proteins were identified, and 1682 proteins were quantified from these corneal tissues. Among these quantified proteins, 290 proteins were significantly changed between normal and alkali burned corneal tissues. Of these significantly changed proteins, 35 were reported or predicted as angiogenesis-related proteins. Then, these 35 proteins were analyzed using Ingenuity Pathway Analysis Software, resulting in 26 proteins enriched and connected to each other in the protein-protein interaction network, such as Lcn-2, αB-crystallin and Serpinf1 (PEDF). These three significantly changed proteins were selected for further Western blotting validation. Consistent with the quantitative proteomic results, Western blotting showed that Lcn-2 and αB-crystallin were significantly up-regulated in CNV model, while PEDF was down-regulated. This study provided increased understanding of angiogenesis-related proteins involved in corneal vascular development, which will be useful in the ophthalmic clinic of specifically target angiogenesis.

  6. A brief history of corneal transplantation: From ancient to modern

    Directory of Open Access Journals (Sweden)

    Alexandra X Crawford

    2013-01-01

    Full Text Available This review highlights many of the fundamental concepts and events in the development of corneal transplantation - from ancient times to modern. Tales of eye, limb, and even heart transplantation appear in ancient and medieval texts; however, in the scientific sense, the original concepts of corneal surgery date back to the Greek physician Galen (130-200 AD. Although proposals to provide improved corneal clarity by surgical interventions, including keratoprostheses, were better developed by the 17 th and 18 th centuries, true scientific and surgical experimentation in this field did not begin until the 19 th century. Indeed, the success of contemporary corneal transplantation is largely the result of a culmination of pivotal ideas, experimentation, and perseverance by inspired individuals over the last 200 years. Franz Reisinger initiated experimental animal corneal transplantation in 1818, coining the term "keratoplasty". Subsequently, Wilhelmus Thorne created the term corneal transplant and 3 years later Samuel Bigger, 1837, reported successful corneal transplantation in a gazelle. The first recorded therapeutic corneal xenograft on a human was reported shortly thereafter in 1838-unsurprisingly this was unsuccessful. Further progress in corneal transplantation was significantly hindered by limited understanding of antiseptic principles, anesthesiology, surgical technique, and immunology. There ensued an extremely prolonged period of debate and experimentation upon the utility of animal compared to human tissue, and lamellar versus penetrating keratoplasty. Indeed, the first successful human corneal transplant was not performed by Eduard Zirm until 1905. Since that first successful corneal transplant, innumerable ophthalmologists have contributed to the development and refinement of corneal transplantation aided by the development of surgical microscopes, refined suture materials, the development of eye banks, and the introduction of

  7. A brief history of corneal transplantation: From ancient to modern.

    Science.gov (United States)

    Crawford, Alexandra Z; Patel, Dipika V; McGhee, Charles Nj

    2013-09-01

    This review highlights many of the fundamental concepts and events in the development of corneal transplantation - from ancient times to modern. Tales of eye, limb, and even heart transplantation appear in ancient and medieval texts; however, in the scientific sense, the original concepts of corneal surgery date back to the Greek physician Galen (130-200 AD). Although proposals to provide improved corneal clarity by surgical interventions, including keratoprostheses, were better developed by the 17(th) and 18(th) centuries, true scientific and surgical experimentation in this field did not begin until the 19(th) century. Indeed, the success of contemporary corneal transplantation is largely the result of a culmination of pivotal ideas, experimentation, and perseverance by inspired individuals over the last 200 years. Franz Reisinger initiated experimental animal corneal transplantation in 1818, coining the term "keratoplasty". Subsequently, Wilhelmus Thorne created the term corneal transplant and 3 years later Samuel Bigger, 1837, reported successful corneal transplantation in a gazelle. The first recorded therapeutic corneal xenograft on a human was reported shortly thereafter in 1838-unsurprisingly this was unsuccessful. Further progress in corneal transplantation was significantly hindered by limited understanding of antiseptic principles, anesthesiology, surgical technique, and immunology. There ensued an extremely prolonged period of debate and experimentation upon the utility of animal compared to human tissue, and lamellar versus penetrating keratoplasty. Indeed, the first successful human corneal transplant was not performed by Eduard Zirm until 1905. Since that first successful corneal transplant, innumerable ophthalmologists have contributed to the development and refinement of corneal transplantation aided by the development of surgical microscopes, refined suture materials, the development of eye banks, and the introduction of corticosteroids. Recent

  8. OPAC AS DOCUMENT RETRIEVAL TOOL: A CASE STUDY OF THE UNIVERSITY OF KASHMIR

    Directory of Open Access Journals (Sweden)

    Uzma Qadri, Research Scholar,

    2012-01-01

    Full Text Available The application of the information and communication technology has changed the entireenvironment of the library including cataloguing. Today, a number of libraries are providingOnline Public Access Cataloguing service to their users to find out their documents and theAllama Iqbal Library, University of Kashmir isn’t an exception. The main purpose of the study isto measure the faculty wise use of OPAC by the P G students of University of Kashmir. Toaccomplish the purpose of the study, survey method was adopted and questionnaire was used asdata collection tool. The questionnaire was distributed among 260 students selecting 10 students from each department in the month of May 2012. However, only 241 students returned the filled questionnaire with response rate of 92.69 %. The results revealed that 60% of the respondents use OPAC to search the library collection whereas 40% don’t use it at all. The students who use OPAC cite many features like time saving; fast response; remote access etc. and the students don’t use OPAC mostly due to awareness problem. This study found that most of the student learn to operate OPAC from themselves followed by friends/colleagues and library staff. The students search the library material mostly through subject, author and title approach. At the end, the fruitful suggestions are provided for greater use of OPAC.

  9. How the machine ‘thinks’: Understanding opacity in machine learning algorithms

    Directory of Open Access Journals (Sweden)

    Jenna Burrell

    2016-01-01

    Full Text Available This article considers the issue of opacity as a problem for socially consequential mechanisms of classification and ranking, such as spam filters, credit card fraud detection, search engines, news trends, market segmentation and advertising, insurance or loan qualification, and credit scoring. These mechanisms of classification all frequently rely on computational algorithms, and in many cases on machine learning algorithms to do this work. In this article, I draw a distinction between three forms of opacity: (1 opacity as intentional corporate or state secrecy, (2 opacity as technical illiteracy, and (3 an opacity that arises from the characteristics of machine learning algorithms and the scale required to apply them usefully. The analysis in this article gets inside the algorithms themselves. I cite existing literatures in computer science, known industry practices (as they are publicly presented, and do some testing and manipulation of code as a form of lightweight code audit. I argue that recognizing the distinct forms of opacity that may be coming into play in a given application is a key to determining which of a variety of technical and non-technical solutions could help to prevent harm.

  10. Coagulation and Fragmentation in molecular clouds. II. The opacity of the dust aggregate size distribution

    CERN Document Server

    Ormel, C W; Tielens, A G G M; Dominik, C; Paszun, D

    2011-01-01

    The dust size distribution in molecular clouds can be strongly affected by ice-mantle formation and (subsequent) grain coagulation. Following previous work where the dust size distribution has been calculated from a state-of-the art collision model for dust aggregates that involves both coagulation and fragmentation (Paper I), the corresponding opacities are presented in this study. The opacities are calculated by applying the effective medium theory assuming that the dust aggregates are a mix of 0.1{\\mu}m silicate and graphite grains and vacuum. In particular, we explore how the coagulation affects the near-IR opacities and the opacity in the 9.7{\\mu}m silicate feature. We find that as dust aggregates grow to {\\mu}m-sizes both the near-IR color excess and the opacity in the 9.7 {\\mu}m feature increases. Despite their coagulation, porous aggregates help to prolong the presence of the 9.7{\\mu}m feature. We find that the ratio between the opacity in the silicate feature and the near-IR color excess becomes lowe...

  11. How the machine ‘thinks’: Understanding opacity in machine learning algorithms

    Directory of Open Access Journals (Sweden)

    Jenna Burrell

    2016-01-01

    Full Text Available This article considers the issue of opacity as a problem for socially consequential mechanisms of classification and ranking, such as spam filters, credit card fraud detection, search engines, news trends, market segmentation and advertising, insurance or loan qualification, and credit scoring. These mechanisms of classification all frequently rely on computational algorithms, and in many cases on machine learning algorithms to do this work. In this article, I draw a distinction between three forms of opacity: (1 opacity as intentional corporate or state secrecy, (2 opacity as technical illiteracy, and (3 an opacity that arises from the characteristics of machine learning algorithms and the scale required to apply them usefully. The analysis in this article gets inside the algorithms themselves. I cite existing literatures in computer science, known industry practices (as they are publicly presented, and do some testing and manipulation of code as a form of lightweight code audit. I argue that recognizing the distinct forms of opacity that may be coming into play in a given application is a key to determining which of a variety of technical and non-technical solutions could help to prevent harm.

  12. Corneal injuries from liquid detergent pods.

    Science.gov (United States)

    Gray, Michael E; West, Constance E

    2014-10-01

    Laundry and dishwasher detergent "pods" were introduced to the United States market in 2010 and are sold by several manufacturers. They represent a high percentage of household cleaning product exposure in the United Kingdom. We present a consecutive case series of 10 children seen in a 9-month period with corneal injuries from exposure to liquid detergent pods.

  13. Evaluation and Treatment of Perioperative Corneal Abrasions

    Directory of Open Access Journals (Sweden)

    Kira L. Segal

    2014-01-01

    Full Text Available Purpose. To evaluate perioperative risk factors for corneal abrasion (CA and to determine current care for perioperative CA in a tertiary care setting. Methods. Hospital-based, cross-sectional study. In Operating Room and Post-Anesthesia Care Units patients, a comparison of cases and controls was evaluated to elucidate risk factors, time to treatment, and most common treatments prescribed for corneal abrasions. Results. 86 cases of corneal abrasion and 89 controls were identified from the 78,542 surgical procedures performed over 2 years. Statistically significant risk factors were age (P=0.0037, general anesthesia (P<0.001, greater average estimated blood loss (P<0.001, eyes taped during surgery (P<0.001, prone position (P<0.001, trendelenburg position (P<0.001, and supplemental oxygen en route to and in the Post-Anesthesia Care Units (P<0.001. Average time to complaint was 129 minutes. 94% of cases had an inpatient ophthalmology consult, with an average time to consult of 164 minutes. The most common treatment was artificial tears alone (40%, followed by combination treatment of antibiotic ointment and artificial tears (35.3%. Conclusions. Trendelenburg positioning is a novel risk factor for CA. Diagnosis and treatment of perioperative corneal abrasions by an ophthalmologist typically require three hours in the tertiary care setting.

  14. Serological profile of candidates for corneal donation

    Directory of Open Access Journals (Sweden)

    Adroaldo Lunardelli

    2014-10-01

    Full Text Available Objetive: The purpose of this study is to map the serological profile of candidates to corneal donation at Irmandade Santa Casa de Misericórdia de Porto Alegre, identifying the percentage of disposal by serology and the marker involved. Methods: There have been analised – retrospectively – the results of serology of all corneal donors, made between the period of 1st january 2006 and 31st december 2012. Data analised were related to age, gender and the results of serology pertinent to viral markers (HBsAg, anti-HBc, anti-HCV and anti-HIV, these, determined by immunosorbent tests (ELISA. Results: In the period of the study, there were 2476 corneal donors at the institution, with a major incidence on the male gender, on an average of 58.7 years old. 23% of retention because of serological unfitness was also identified, that is, 570 samples were non-negative to any of the used tests. The marker anti- HBc was the most prevalent on the studied population, followed by the Hepatitis C virus (HCV and by the Human Immunodeficiency Virus (HIV. Conclusion: From the data found through this study, it is essential to have the participation of an efficient service on the serological evaluation of the candidates to corneal donation, once the security of the receptor must be taken into consideration in a population of donors with 23% of unfitness prevalence, in which the most prevalent marker is the one of Hepatits B.

  15. Peptide Amphiphiles in Corneal Tissue Engineering

    Directory of Open Access Journals (Sweden)

    Martina Miotto

    2015-08-01

    Full Text Available The increasing interest in effort towards creating alternative therapies have led to exciting breakthroughs in the attempt to bio-fabricate and engineer live tissues. This has been particularly evident in the development of new approaches applied to reconstruct corneal tissue. The need for tissue-engineered corneas is largely a response to the shortage of donor tissue and the lack of suitable alternative biological scaffolds preventing the treatment of millions of blind people worldwide. This review is focused on recent developments in corneal tissue engineering, specifically on the use of self-assembling peptide amphiphiles for this purpose. Recently, peptide amphiphiles have generated great interest as therapeutic molecules, both in vitro and in vivo. Here we introduce this rapidly developing field, and examine innovative applications of peptide amphiphiles to create natural bio-prosthetic corneal tissue in vitro. The advantages of peptide amphiphiles over other biomaterials, namely their wide range of functions and applications, versatility, and transferability are also discussed to better understand how these fascinating molecules can help solve current challenges in corneal regeneration.

  16. Corneal topography measurements for biometric applications

    Science.gov (United States)

    Lewis, Nathan D.

    The term biometrics is used to describe the process of analyzing biological and behavioral traits that are unique to an individual in order to confirm or determine his or her identity. Many biometric modalities are currently being researched and implemented including, fingerprints, hand and facial geometry, iris recognition, vein structure recognition, gait, voice recognition, etc... This project explores the possibility of using corneal topography measurements as a trait for biometric identification. Two new corneal topographers were developed for this study. The first was designed to function as an operator-free device that will allow a user to approach the device and have his or her corneal topography measured. Human subject topography data were collected with this device and compared to measurements made with the commercially available Keratron Piccolo topographer (Optikon, Rome, Italy). A third topographer that departs from the standard Placido disk technology allows for arbitrary pattern illumination through the use of LCD monitors. This topographer was built and tested to be used in future research studies. Topography data was collected from 59 subjects and modeled using Zernike polynomials, which provide for a simple method of compressing topography data and comparing one topographical measurement with a database for biometric identification. The data were analyzed to determine the biometric error rates associated with corneal topography measurements. Reasonably accurate results, between three to eight percent simultaneous false match and false non-match rates, were achieved.

  17. Aspergillus terreus recovered from a corneal scraping.

    Science.gov (United States)

    Campbell, Suzanne

    2014-01-01

    A 52 year old, healthy male presented to his optometrist complaining of redness and irritation in the right eye. A foreign body was removed from the eye. The patient was started on ophthalmic solutions of vigamox and systane. At 48 hours, the patient reported increased redness, limited vision, and yellow discharge from the eye. The patient was referred to an ophthalmologist for further evaluation. Physical assessment revealed a superlative central infiltrate (extreme, centrally located injury that had permeated the cornea), diffuse corneal haze, and edema with a 3- to 4+ conjunctival injection and a 1 millimeter hypopyon (an effusion of pus into the anterior chamber of the eye). Corneal scrapings were collected for aerobic and anaerobic bacterial and fungal cultures. The patient was then prescribed. vancomycin, tobramycin, and natamycin ophthalmic eyedrops. On day three, fungal culture results indicated possible fungal forms seen. On day 12, results from the fungal culture of the corneal scraping revealed the causative agent to be Aspergillus terreus. Voriconazole eyedrops were added to the treatment regimen and continued for 10 weeks. The physician order for a fungal culture as well as laboratory data providing the final identification of Aspergillus terreus and laboratory comments indicating an elevated minimum inhibitory concentration (MIC) (> 2 microg/mL) to amphotericin B is associated with treatment failure positively impacted the patient outcome. After completion of the treatment regimen, a photo-therapeutic keratectomy (PTK) was performed in an attempt to remove the dense corneal scarring caused by the fungal infection.

  18. [Purulent corneal ulcers: etiology, pathogenesis, classification].

    Science.gov (United States)

    Kasparova, Evg A

    2015-01-01

    Advanced purulent corneal ulcer, as well as abscess, is a serious vision-threatening condition notable for its fulminant course and possible loss of the eye due to endophthalmitis. Its leading causes, pathogenesis, and classifications are described and analyzed in this paper.

  19. Change in corneal curvature induced by surgery

    NARCIS (Netherlands)

    G. van Rij (Gabriel)

    1987-01-01

    textabstractThe first section deals with the mechanisms by which sutures, incisions and intracorneal contact lenses produce a change in corneal curvature. To clarify the mechanisms by which incisions and sutures produce astigmatism, we made incisions and placed sutures in the corneoscleral limbus of

  20. Autophagy in granular corneal dystrophy type 2.

    Science.gov (United States)

    Choi, Seung-Il; Kim, Eung Kweon

    2016-03-01

    Autophagy is a lysosomal degradative process that is essential for cellular homeostasis and metabolic stress adaptation. Defective autophagy is involved in the pathogenesis of many diseases including granular corneal dystrophy type 2 (GCD2). GCD2 is an autosomal dominant disorder caused by substitution of histidine for arginine at codon 124 (R124H) in the transforming growth factor β-induced gene (TGFBI) on chromosome 5q31. Transforming growth factor β-induced protein (TGFBIp) is degraded by autophagy, but mutant-TGFBIp accumulates in autophagosomes and/or lysosomes, despite significant activation of basal autophagy, in GCD2 corneal fibroblasts. Furthermore, inhibition of autophagy induces cell death of GCD2 corneal fibroblasts through active caspase-3. As there is currently no pharmacological treatment for GCD2, development of novel therapies is required. A potential strategy for preventing cytoplasmic accumulation of mutant-TGFBIp in GCD2 corneal fibroblasts is to enhance mutant-TGFBIp degradation. This could be achieved by activation of the autophagic pathway. Here, we will consider the role and the potential therapeutic benefits of autophagy in GCD2, with focus on TGFBIp degradation, in light of the recently established role of autophagy in protein degradation.

  1. Polysaccharide coating of human corneal endothelium

    DEFF Research Database (Denmark)

    Schroder, H D; Sperling, S

    1977-01-01

    Electron microscopy revealed the presence of a 600-1500 A thick layer of polysaccharide on the surface of human corneal endothelial cells. The surface layer was visualized by combined fixation and staining in a mixture of ruthenium red and osmium tetroxide. The coating material was stable...

  2. Traumatic wound dehiscence after corneal keratoplasty

    Directory of Open Access Journals (Sweden)

    Patrick Frensel Tzelikis

    2015-10-01

    Full Text Available ABSTRACTPurpose:To assess patient characteristics, risk factors, outcomes, and the treatment of wound dehiscence (WD in patients after corneal keratoplasty.Methods:Retrospective chart review of 11 eyes of 11 patients with corneal grafts who underwent repair of WD from January 1, 2004 to December 31, 2012 at Hospital Oftalmologico de Brasilia.Results:Eight (72.7% patients were men and three were women. Six (54.5% patients had deep anterior lamellar keratoplasty (DALK and 5 had penetrating keratoplasty. The mean age at trauma was 31.1 years. The mean time from corneal keratoplasty to WD was 12.82 months (range, 3-33 months. The mean best-corrected visual acuity of patients before trauma was 20/60 (0.48 logMAR and after final treatment was 20/160 (0.90 logMAR (P=0.15. In one case, visual acuity decreased to no light perception because of retinal detachment and phthisis bulbi. Accidental blunt trauma and fall were the most common causes of WD.Conclusion:Patients who undergo corneal keratoplasty have a life-long risk of WD. The full-thickness rupture at the graft-host junction in our study suggests that the junction remains vulnerable, even following DALK, and can rupture with trauma. In our series, depending upon the severity of the trauma, postkeratoplastic WD can be associated with a good visual prognosis.

  3. Past and present of corneal refractive surgery

    DEFF Research Database (Denmark)

    Vestergaard, Anders Højslet

    Surgical correction of refractive errors is becoming increasingly popular. In the 1990s, the excimer laser revolutionized the field of corneal refractive surgery with PRK and LASIK, and lately refractive lenticule extraction (ReLEx) of intracorneal tissue, using only a femtosecond laser, has become...

  4. Functional characterization of antibodies against Neisseria gonorrhoeae opacity protein loops.

    Directory of Open Access Journals (Sweden)

    Jessica G Cole

    Full Text Available BACKGROUND: The development of a gonorrhea vaccine is challenged by the lack of correlates of protection. The antigenically variable neisserial opacity (Opa proteins are expressed during infection and have a semivariable (SV and highly conserved (4L loop that could be targeted in a vaccine. Here we compared antibodies to linear (Ab(linear and cyclic (Ab(cyclic peptides that correspond to the SV and 4L loops and selected hypervariable (HV(2 loops for surface-binding and protective activity in vitro and in vivo. METHODS/FINDINGS: Ab(SV cyclic bound a greater number of different Opa variants than Ab(SV linear, including variants that differed by seven amino acids. Antibodies to the 4L peptide did not bind Opa-expressing bacteria. Ab(SV (cyclic and Ab(HV2 (cyclic, but not Ab(SV (linear or Ab(HV2 linear agglutinated homologous Opa variants, and Ab(HV2BD (cyclic but not Ab(HV2BD (linear blocked the association of OpaB variants with human endocervical cells. Only Ab(HV2BD (linear were bactericidal against the serum resistant parent strain. Consistent with host restrictions in the complement cascade, the bactericidal activity of Ab(HV2BD (linear was increased 8-fold when rabbit complement was used. None of the antibodies was protective when administered vaginally to mice. Antibody duration in the vagina was short-lived, however, with <50% of the antibodies recovered 3 hrs post-administration. CONCLUSIONS: We conclude that an SV loop-specific cyclic peptide can be used to induce antibodies that recognize a broad spectrum of antigenically distinct Opa variants and have agglutination abilities. HV(2 loop-specific cyclic peptides elicited antibodies with agglutination and adherence blocking abilities. The use of human complement when testing the bactericidal activity of vaccine-induced antibodies against serum resistant gonococci is also important.

  5. Tratamento da úlcera corneana experimental com membrana amniótica Experimental corneal ulcer treated with amniotic membrane

    Directory of Open Access Journals (Sweden)

    Eliana Cristina Louza Monteiro

    2000-02-01

    examinations and the results were compared through variance analysis. Results: Morphometric results showed corneal ulcer in G2 at M1; corneal opacity was identified in the central area and was significantly larger in G1 at M3. New corneal vessels were more active in the G1 animals. Histopathologic evaluation revealed epithelial defects in two animals of G1 at M2, and in two of G2 at M1; stromal edema was more intense in G1, as well as the presence of new vessels. Conclusion: The use of homologous MA in the treatment of experimental corneal ulcer did not accelerate epithelial healing but it prevented stromal edema and new vessel formation. Epithelial healing was poorer in the central region of the cornea.

  6. Evaluation of a 345 nm Femtosecond Laser for Corneal Surgery with Respect to Intraocular Radiation Hazard.

    Directory of Open Access Journals (Sweden)

    Johannes Menzel-Severing

    Full Text Available We report our findings from a preclinical safety study designed to assess potential side effects of corneal ultraviolet femtosecond laser treatment on lens and retina.Refractive lenticules (-5 dpt with a diameter of 6 mm were created in the right cornea of eight Dutch Belted rabbits. Radiant exposure was 0.5 J/cm² in two animals and 18 J/cm² in six animals. The presence of lens opacities was assessed prior to and up to six months following laser application using Scheimpflug images (Pentacam, Oculus and backscatter analysis (Opacity Lensmeter 702, Interzeag. Ganzfeld flash and flicker electroretinogram (ERG recordings were obtained from both eyes prior to and up to six weeks following laser application. At the study endpoint, retinas were examined by light microscopy.Independent of energy dose applied, no cataract formation could be observed clinically or with either of the two objective methods used. No changes in ERG recordings over time and no difference between treated and untreated eye were detected. Histologically, retinal morphology was preserved and retinal pigment epithelium as well as photoreceptor inner and outer segments appeared undamaged. Quantitative digital image analysis did not reveal cell loss in inner or outer nuclear layers.Our analysis confirms theoretical considerations suggesting that ultraviolet femtosecond laser treatment of the cornea is safe for intraocular tissues. Transmitted light including stray light induces no photochemical effects in lens or retina at energy levels much higher than required for the clinical purpose. These conclusions cannot be applied to eyes with pre-existing retinal damage, as these may be more vulnerable to light.

  7. Oxygen-deficient metabolism and corneal edema.

    Science.gov (United States)

    Leung, B K; Bonanno, J A; Radke, C J

    2011-11-01

    Wear of low-oxygen-transmissible soft contact lenses swells the cornea significantly, even during open eye. Although oxygen-deficient corneal edema is well-documented, a self-consistent quantitative prediction based on the underlying metabolic reactions is not available. We present a biochemical description of the human cornea that quantifies hypoxic swelling through the coupled transport of water, salt, and respiratory metabolites. Aerobic and anaerobic consumption of glucose, as well as acidosis and pH buffering, are incorporated in a seven-layer corneal model (anterior chamber, endothelium, stroma, epithelium, postlens tear film, contact lens, and prelens tear film). Corneal swelling is predicted from coupled transport of water, dissolved salts, and especially metabolites, along with membrane-transport resistances at the endothelium and epithelium. At the endothelium, the Na+/K+ - ATPase electrogenic channel actively transports bicarbonate ion from the stroma into the anterior chamber. As captured by the Kedem-Katchalsky membrane-transport formalism, the active bicarbonate-ion flux provides the driving force for corneal fluid pump-out needed to match the leak-in tendency of the stroma. Increased lactate-ion production during hypoxia osmotically lowers the pump-out rate requiring the stroma to swell to higher water content. Concentration profiles are predicted for glucose, water, oxygen, carbon dioxide, and hydronium, lactate, bicarbonate, sodium, and chloride ions, along with electrostatic potential and pressure profiles. Although the active bicarbonate-ion pump at the endothelium drives bicarbonate into the aqueous humor, we find a net flux of bicarbonate ion into the cornea that safeguards against acidosis. For the first time, we predict corneal swelling upon soft-contact-lens wear from fundamental biophysico-chemical principles. We also successfully predict that hypertonic tear alleviates contact-lens-induced edema.

  8. Partial-thickness corneal tissue restoration after a chemical burn

    Directory of Open Access Journals (Sweden)

    Galan A

    2016-04-01

    Full Text Available Alessandro Galan, Anton Giulio Catania, Giuseppe Lo Giudice San Paolo Ophthalmic Center, San Antonio Hospital, Padova, Italy Purpose: We describe a case of full-thickness corneal restoration after an acute corneal burn with an acid agent. Methods: A 32-year-old male reported painful discomfort, redness, photophobia, and a decrease in visual acuity in the left eye after a unilateral burn with an acid agent. Slit-lamp examination revealed massive corneal melting involving necrotic sequestrum of the entire corneal surface. Surgical approach was carried out in order to preserve residual ocular tissues. Results: Extensive corneal–conjunctival layer curettage of the necrotic tissue was performed showing perfectly clear undamaged deep lamellar corneal layers. The patient underwent multilayered amniotic membrane transplantation and total capsular–conjunctival flap in order to preserve ocular tissue from further melting or corneal perforation. A complete and spontaneous “restitutio ad integrum” of the corneal layers was shown during the follow-up. The cornea was perfectly clear with restored normal anatomical architecture. Conclusion: In this case, a spontaneous full-thickness corneal tissue restoration occurred after an acute chemical burn. Studies about the mechanisms whereby different cells interact and replicate within the stroma may unveil the biology behind corneal regeneration and transparency. Keywords: amniotic membrane, chemical burn, corneal healing

  9. Emodin ameliorates lipopolysaccharides-induced corneal inflammation in rats

    Institute of Scientific and Technical Information of China (English)

    Guo-Ling; Chen; Jing-Jing; Zhang; Xin; Kao; Lu-Wan; Wei; Zhi-Yu; Liu

    2015-01-01

    · AIM: To investigate the effect of emodin on pseudomonas aeruginosa lipopolysaccharides(LPS)-induced corneal inflammation in rats.· METHODS: Corneal infection was induced by pseudomonas aeruginosa LPS in Wistar rats. The inflammation induced by LPS were examined by slit lamp microscope and cytological checkup of aqueous humor.Corneal tissue structure was observed by hematoxylin and eosin(HE) staining. The activation of nuclear factor kappa B(NF-κB) was determined by Western blot.Messenger ribonucleic acid(m RNA) of tumor necrosis factor-α(TNF-α) and intercellular adhesion molecule-1(ICAM-1) in LPS-challenged rat corneas were measured with reverse transcription-polymerase chain reaction(RT-PCR).· RESULTS: Typical manifestations of acute corneal inflammation were observed in LPS-induce rat model,and the corneal inflammatory response and structure were improved in rats pretreated with emodin. Treatment with emodin could improve corneal structure, reduce corneal injure by reducing corneal inflammatory response. Emodin could inhibit the decreasing lever of inhibitor of kappa B alpha(IкBα) express, and the m RNA expression of TNF-α and ICAM-1 in corneal tissues was also inhibited by emodin. The differences were statistically significant between groups treated with emodin and those without treatment(P <0.01).·CONCLUSION: Emodin could ameliorate LPS-induced corneal inflammation, which might via inhibiting the activation of NF-κB.

  10. Ocular histopathological changes after eyeball enucleation induced by corneal trauma

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Objective: To observe the ocular histopathological changes aftereyeball enucleation induced by corneal trauma.Methods: Light microscopic examination was done on 117 eyeball specimens enucleated after corneal trauma (18 with corneal fissure and 99 with corneal perforating trauma).Results: Acute, subacute or chronic inflammatory changes, and fibrous membrane formation were observed in well-closed corneal wounds, whereas inflammation, atrophy and scar were observed in the focal tissues. But at the late period, secondary glaucoma, retinal detachment, endophthalmitis and eyeball atrophy resulted in blindness. Corneal fistula was observed in those with inadequate cure of wounds caused by ingrowth of corneal epithelium, embedment of iris and vitreous body, and large area of centrally located tissue deficiency of the corneal. A high incidence of endophthalmitis was noted due to the presence of corneal fistula. Severe inflammation was observed in the anterior segmental tissues with fibrous infiltration in the anterior chamber, which might result in rapid destruction of the eyeballs.Conclusions: Ocular pathology varies with the difference of the position, form, size and closing conditions of the corneal laceration after trauma.

  11. Anatomical characterization of central, apical and minimal corneal thickness

    Institute of Scientific and Technical Information of China (English)

    Federico; Saenz-Frances; Martha; Cecilia; Bermúdez-Vallecilla; Lara; Borrego-Sanz; Luis; Jaez; J; osé; Marìa; Martinez-de-la-Casa; Laura; Morales-Fernandez; Enrique; Santos-Bueso; Julián; Garcia-Sanchez; Julián; Garcia-Feijoo

    2014-01-01

    ·AIM: To anatomically locate the points of minimum corneal thickness and central corneal thickness(pupil center) in relation to the corneal apex.·METHODS: Observational, cross-sectional study, 299 healthy volunteers. Thickness at the corneal apex(AT),minimum corneal thickness(MT) and corneal thickness at the pupil center(PT) were determined using the pentacam. Distances from the corneal apex to MT(MD)and PT(PD) were calculated and their quadrant position(taking the corneal apex as the reference) determined:point of minimum thickness(MC) and point of central thickness(PC) depending on the quadrant position. Two multivariate linear regression models were constructed to examine the influence of age, gender, power of the flattest and steepest corneal axes, position of the flattest axis, corneal volume(determined using the Pentacam)and PT on MD and PD. The effects of these variables on MC and PC were also determined in two multinomial regression models.·RESULTS: MT was located at a mean distance of 0.909 mm from the apex(79.4% in the inferior-temporal quadrant). PT was located at a mean distance of 0.156 mm from the apex. The linear regression model for MD indicated it was significantly influenced by corneal volume(B =-0.024; 95% CI:-0.043 to-0.004). No significant relations were identified in the linear regression model for PD or the multinomial logisticregressions for MC and PC.·CONCLUSION: MT was typically located at the inferiortemporal quadrant of the cornea and its distance to the corneal apex tended to decrease with the increment of corneal volume.

  12. Anatomical characterization of central, apical and minimal corneal thickness

    Directory of Open Access Journals (Sweden)

    Federico Saenz-Frances

    2014-08-01

    Full Text Available AIM: To anatomically locate the points of minimum corneal thickness and central corneal thickness (pupil center in relation to the corneal apex.METHODS: Observational, cross-sectional study, 299 healthy volunteers. Thickness at the corneal apex (AT, minimum corneal thickness (MT and corneal thickness at the pupil center (PT were determined using the pentacam. Distances from the corneal apex to MT (MD and PT (PD were calculated and their quadrant position (taking the corneal apex as the reference determined:point of minimum thickness (MC and point of central thickness (PC depending on the quadrant position. Two multivariate linear regression models were constructed to examine the influence of age, gender, power of the flattest and steepest corneal axes, position of the flattest axis, corneal volume (determined using the Pentacam and PT on MD and PD. The effects of these variables on MC and PC were also determined in two multinomial regression models.RESULTS: MT was located at a mean distance of 0.909 mm from the apex (79.4% in the inferior-temporal quadrant. PT was located at a mean distance of 0.156 mm from the apex. The linear regression model for MD indicated it was significantly influenced by corneal volume (B=-0.024; 95%CI:-0.043 to -0.004. No significant relations were identified in the linear regression model for PD or the multinomial logistic regressions for MC and PC.CONCLUSION: MT was typically located at the inferior-temporal quadrant of the cornea and its distance to the corneal apex tended to decrease with the increment of corneal volume.

  13. Catarata polar anterior piramidal deslocada para a câmara anterior causando edema de córnea: relato de caso Corneal edema caused by a pyramidal anterior polar cataract dislocated to the anterior chamber: case report

    Directory of Open Access Journals (Sweden)

    Ramon Coral Ghanem

    2004-08-01

    Full Text Available Cataratas polares anteriores piramidais são opacidades cônicas que se projetam para a câmara anterior a partir da cápsula anterior do cristalino. Na grande maioria dos pacientes a opacidade permanece aderida e estável durante toda a vida. O objetivo deste trabalho é documentar uma manifestação incomum desse tipo de catarata: a deiscência espontânea das pirâmides para a câmara anterior causando descompensação endotelial e edema corneal bilateral. Relatamos o caso de uma paciente feminina, de 66 anos, branca, que apresentava edema corneal localizado inferiormente no olho direito associado à lesão nodular branco-esclerótica compatível com a pirâmide anterior da catarata polar. O olho esquerdo apresentava edema corneal difuso intenso e presença de uma catarata polar anterior com a região piramidal deslocada para a câmara anterior. Sabe-se que a pirâmide anterior pode permanecer inabsorvida na câmara anterior por longo período, pois é composta de tecido colágeno denso. Isto causa perda endotelial progressiva e edema corneal e deve ser considerada indicação de remoção cirúrgica da catarata polar anterior e de seu fragmento. Ressalta-se, também, a importância do bom senso no julgamento das cataratas polares anteriores, considerando-se tamanho da opacidade, simetria das opacidades e componente cortical associado, na tentativa de se evitar ambliopia.Pyramidal anterior polar cataracts are conical opacities that project into the anterior chamber from the anterior capsule of the lens. In the vast majority of patients the opacity remains bound and stable throughout life. We report an unusual complication of this type of cataract: spontaneous dehiscence of the pyramids to the anterior chamber causing bilateral endothelial damage and corneal edema. 66-year-old white woman presented with inferior corneal edema in the right eye and diffuse corneal edema in the left eye. A white nodular lesion was observed in the inferior angle

  14. Corneal collagen cross-linking to stop corneal ectasia exacerbated by radial keratotomy.

    Science.gov (United States)

    Mazzotta, Cosimo; Baiocchi, Stefano; Denaro, Rosario; Tosi, Gian Marco; Caporossi, Tomaso

    2011-02-01

    To assess the efficacy of riboflavin ultraviolet A (UV-A) corneal collagen cross-linking in the management of keratoconic corneal ectasia exacerbated by radial keratotomy (RK). A patient with progressive corneal ectasia and hyperopic shift, occurring 10 years after RK performed in the left eye, was treated with riboflavin UV-A corneal collagen cross-linking according to the Siena protocol: Pilocarpin 0.1% drop (1 hour before), lidocaine 4% drops 15 minutes before, mechanical scraping of epithelium (9-mm-diameter area), preirradiation stromal soaking for 10 minutes in riboflavin 0.1%-dextrane 20% (Ricrolin; Sooft Italy) applied every 2 minutes, and 30 minutes of total exposure (6 steps of 5 minutes) to solid-state UV-A illuminator (Caporossi, Baiocchi, Mazzotta Vega X linker; CSO Opthalmics, Florence, Italy), energy delivered 3 mW/cm, and irradiated area 9 mm in diameter. After the operation, uncorrected visual acuity and best spectacle-corrected visual acuity improved from 0.2 to 0.6 and from 0.3 to 0.8 Snellen lines, respectively, in a 12-month follow-up. Improved topographical K readings and corneal symmetry index were also recorded starting from the first postoperative month and continuing thereafter. No adverse effects were recorded after treatment. Riboflavin UV-A-induced corneal cross-linking seems to be a promising surgical option in the management of unstable corneal ectasia exacerbated by RK, particularly in eyes with preexisting keratoconus. A large cohort and longer follow-up are needed to determine its long-term efficacy in this clinical setting.

  15. Manifestaciones corneales en las enfermedades sistémicas Corneal manifestations in systemic diseases

    Directory of Open Access Journals (Sweden)

    J. Zarranz-Ventura

    2008-01-01

    Full Text Available Un gran número de enfermedades sistémicas presentan manifestaciones corneales dentro de su espectro de enfermedad. El estudio detallado de todos los cuadros que asocian patología corneal resulta inabarcable, por ello se presentan las enfermedades más prevalentes o características. Este estudio contempla las enfermedades pulmonares y conectivopatías (colagenosis, enfermedades reumatológicas y enfermedades inflamatorias idiopáticas, las enfermedades dermatológicas, cardiovasculares, hematológicas y la patología digestiva y hepatopancreática. Se contemplan también, por ocasionar alteraciones corneales, las enfermedades endocrinas y metabólicas con algunas situaciones de malnutrición y estados carenciales, las infecciones sistémicas y las enfermedades renales. Otro área que produce afectación corneal es la patología otorrinolaringológica y las enfermedades genéticas. Se repasa brevemente la toxicidad y las alteraciones corneales provocadas por fármacos.Systemic diseases affecting the cornea have a wide range of manifestations. The detailed study of all pathologies that cause corneal alteration is unapproachable, so we have centered our interest in the most prevalent or characteristic of them. In this paper we have divided these pathologies in sections to facilitate their study. Pulmonar and conective tissue (like colagen, rheumatologic and idiopathic inflamatory diseases, dermatologic, cardiovascular, hematologic, digestive and hepatopancreatic diseases with corneal alteration are described. Endocrine and metabolic diseases, malnutrition and carential states are also studied, as well as some otorhinolaryngologic and genetic diseases that affect the cornea. Finally, a brief report of ocular toxicity induced by drugs is referred.

  16. Iron Opacity Bump Changes the Stability and Structure of Accretion Disks in Active Galactic Nuclei

    Science.gov (United States)

    Jiang, Yan-Fei; Davis, Shane W.; Stone, James M.

    2016-08-01

    Accretion disks around supermassive black holes have regions where the Rosseland mean opacity can be larger than the electron scattering opacity due to the large number of bound-bound transitions in iron. We study the effects of this iron opacity “bump” on the thermal stability and vertical structure of radiation-pressure-dominated accretion disks, utilizing three-dimensional radiation magnetohydrodynamic (MHD) simulations in the local shearing box approximation. The simulations self-consistently calculate the heating due to MHD turbulence caused by magneto-rotational instability and radiative cooling by using the radiative transfer module based on a variable Eddington tensor in Athena. For a 5 × 108 solar mass black hole with ˜3% of the Eddington luminosity, a model including the iron opacity bump maintains its structure for more than 10 thermal times without showing significant signs of thermal runaway. In contrast, if only electron scattering and free-free opacity are included as in the standard thin disk model, the disk collapses on the thermal timescale. The difference is caused by a combination of (1) an anti-correlation between the total optical depth and the midplane pressure, and (2) enhanced vertical advective energy transport. These results suggest that the iron opacity bump may have a strong impact on the stability and structure of active galactic nucleus (AGN) accretion disks, and may contribute to a dependence of AGN properties on metallicity. Since this opacity is relevant primarily in UV emitting regions of the flow, it may help to explain discrepancies between observation and theory that are unique to AGNs.

  17. Experimental Validation of Modeled Fe Opacities at Conditions Approaching the Base of the Solar Convection Zone

    Science.gov (United States)

    Nagayama, Taisuke

    2013-10-01

    Knowledge of the Sun is a foundation for other stars. However, after the solar abundance revision in 2005, standard solar models disagree with helioseismic measurements particularly at the solar convection zone base (CZB, r ~ 0 . 7 ×RSun) [Basu, et al., Physics Reports 457, 217 (2008)]. One possible explanation is an underestimate in the Fe opacity at the CZB [Bailey et al., Phys. Plasmas 16, 058101 (2009)]. Modeled opacities are important physics inputs for plasma simulations (e.g. standard solar models). However, modeled opacities are not experimentally validated at high temperatures because of three challenging criteria required for reliable opacity measurements: 1) smooth and strong backlighter, 2) plasma condition uniformity, and 3) simultaneous measurements of plasma condition and transmission. Fe opacity experiments are performed at the Sandia National Laboratories (SNL) Z-machine aiming at conditions close to those at the CZB (i.e. Te = 190 eV, ne = 1 ×1023 cm-3). To verify the quality of the experiments, it is critical to investigate how well the three requirements are satisfied. The smooth and strong backlighter is provided by the SNL Z-pinch dynamic hohlraum. Fe plasma condition is measured by mixing Mg into the Fe sample and employing Mg K-shell line transmission spectroscopy. Also, an experiment is designed and performed to measure the level of non-uniformity in the Fe plasma by mixing Al and Mg dopants on the opposite side of the Fe sample and analyzing their spectra. We will present quantitative results on these investigations as well as the comparison of the measured opacity to modeled opacities. Sandia is a multi-program laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy under contract DE-AC04-94AL85000.

  18. The influence of urban area opacity on biologically active UV-B irradiance

    Science.gov (United States)

    Chubarova, Nataly; Rozental', Victor

    2013-04-01

    The study of UV irradiance changes in urban area is an essential problem due to the significant effect of UV irradiance on human health which can be positive (vitamin D synthesis) and negative (erythema, skin cancer, eye damage). According to the results of several experiments within the Moscow megacity we studied the effects of urban area opacity on the different types of biologically active UV-B irradiance on the base of a specially developed mobile photometric complex snd additional measurements of the urban opacity by Nikon Fisheye Converter FC-E8. We analyzed both the level of erythemally-active irradiance and the UV eye damaging radiation using the broadband UVB-1 YES pyranometer calibrated against ultraviolet spectroradiometer Bentham DTM-300 of the Medical University of Innsbruck (courtesy of Dr. M.Blumthaler). In order to estimate the effects of the urban opacity the measurements were normalized on similar measurements at the Meteorological Observatory of Moscow State University with zero opacity. This ratio is defined as an urban radiative transmittance (URT). Different atmospheric conditions were considered. In cloudy conditions the effect of opacity on URT is much less than that in conditions when the sun disk is open from clouds. We revealed some spectral features in transmittance of biologically active UV-B irradiance which is characterized by higher URT variations in overcast cloudy conditions due to more intensive scattering and smaller direct solar radiation component. In the absence of cloudiness the effect of opacity was studied for open and screening solar disk conditions. We obtained much higher URT in UVB spectral region compared with that for total solar irradiance for screening solar disk conditions with a significant URT dependence on the opacity only in UVB spectral region. No URT dependence was obtained for total solar irradiance in these conditions. Some model calculations were fulfilled to match the experimental results.

  19. Interferometer for measuring dynamic corneal topography

    Science.gov (United States)

    Micali, Jason Daniel

    The cornea is the anterior most surface of the eye and plays a critical role in vision. A thin fluid layer, the tear film, coats the outer surface of the cornea and serves to protect, nourish, and lubricate the cornea. At the same time, the tear film is responsible for creating a smooth continuous surface where the majority of refraction takes place in the eye. A significant component of vision quality is determined by the shape of the cornea and stability of the tear film. It is desirable to possess an instrument that can measure the corneal shape and tear film surface with the same accuracy and resolution that is currently performed on common optical elements. A dual interferometer system for measuring the dynamic corneal topography is designed, built, and verified. The completed system is validated by testing on human subjects. The system consists of two co-aligned polarization splitting Twyman-Green interferometers designed to measure phase instantaneously. The primary interferometer measures the surface of the tear film while the secondary interferometer simultaneously tracks the absolute position of the cornea. Eye motion, ocular variation, and a dynamic tear film surface will result in a non-null configuration of the surface with respect to the interferometer system. A non-null test results in significant interferometer induced errors that add to the measured phase. New algorithms are developed to recover the absolute surface topography of the tear film and corneal surface from the simultaneous interferometer measurements. The results are high-resolution and high-accuracy surface topography measurements of the in vivo cornea that are captured at standard camera frame rates. This dissertation will cover the development and construction of an interferometer system for measuring the dynamic corneal topography of the human eye. The discussion starts with the completion of an interferometer for measuring the tear film. The tear film interferometer is part of an

  20. Alterações corneanas pós-tracoma não associadas a entrópio ou triquíase Corneal findings not related to entropion or trichiasis after trachoma

    Directory of Open Access Journals (Sweden)

    Alessandra Pinheiro Chaves

    2001-08-01

    Full Text Available Objetivo: Descrever alterações corneanas pós-tracoma não associadas a deformidades palpebrais. Métodos: Foi realizada avaliação oftalmológica completa em 7 pacientes do ambulatório de Córnea e Doenças Externas da Escola Paulista de Medicina da Universidade Federal de São Paulo. Para o nosso estudo selecionamos pacientes com diagnóstico prévio de tracoma sem deformidades palpebrais, história pregressa de correção de entrópio ou epilação, mas com opacidades corneanas. Resultados: Dentre os achados oftalmológicos observados neste estudo destacaram-se: opacidade corneana bilateral em 100% dos casos, afinamento corneano em 85,7% dos casos, pannus superior bilateral em 71,4% dos casos e fibrose da conjuntiva tarsal superior bilateral em 85,7% dos casos. Conclusão: As alterações corneanas pós-tracomatosas podem-se manifestar sob diversas formas clínicas, incluindo opacidades, afinamentos, ceratites secundárias a infecção, vas-cularização, ectasias, alteração da sensibilidade e xerose. Na ausência de entrópio ou triquíase, estas alterações podem resultar de inflamação tracomatosa, ceratite intersticial ou formas de tratamento utilizadas no passado, no entanto a sua fisiopatologia ainda é controversa.Purpose: To describe corneal findings not related to eyelid involvement after trachoma. Methods: Complete ocular evaluation was performed in 7 patients from the Cornea and External Diseases Clinics of the Escola Paulista de Medicina -Universidade Federal de São Paulo. The selected patients had a previous diagnosis of trachoma with no eyelid deformities, previous entropion repair or trichiasis, but presented corneal opacities. Results: The most common findings were bilateral corneal opacities in 100% of the cases, corneal thinning in 85.7% of the cases, bilateral superior pannus in 71.4% of the cases and bilateral superior tarsal conjunctiva fibrosis in 85.7% of the cases. Conclusion: Corneal findings after trachoma

  1. Spontaneous corneal melting in pregnancy: a case report

    Directory of Open Access Journals (Sweden)

    Arya Sudesh K

    2007-11-01

    Full Text Available Abstract Background To report a case of spontaneous corneal melting in pregnancy. We reviewed the literature on corneal melting and the effect of pregnancy on cornea and collagen containing tissues. Case presentation A 29-year-old woman who underwent radial keratotomy in both eyes followed by trabeculectomy in her left eye developed corneal melting in the same eye, in her seventh month of pregnancy. Despite screening, no infectious or immune mediated condition could be identified. She was managed conservatively with cyanoacrylate glue, bandage contact lens, lubricants and antibiotics. Conclusion It may not always be possible to find the underlying cause of corneal melting but the more common underlying causes should be ruled out by proper investigations. Pregnancy with its host of hormonal changes could potentially have some effect on corneal collagen leading to corneal melting in compromised corneas.

  2. Systemic Immunomodulatory Strategies in High-risk Corneal Transplantation

    Science.gov (United States)

    Abud, Tulio B.; Di Zazzo, Antonio; Kheirkhah, Ahmad; Dana, Reza

    2017-01-01

    The cornea is the most commonly transplanted tissue in the body. Although corneal grafts generally have high success rates, transplantation onto inflamed and vascularized host beds, or so-called high-risk corneal transplantation, has a high rate of graft rejection. The management of this high-risk corneal transplantation is challenging and involves numerous measures. One of the key measures to prevent graft rejection in these cases is the use of systemic immunosuppressive agents. In this article, we will review the systemic immunosuppressive agents most commonly used for high-risk corneal transplantation, which include corticosteroids, cysclosporine A, tacrolimus, mycophenolate mofetil, and rapamycin. Benefits, risks, and published data on the use of these medications for high-risk corneal transplantation will be detailed. We will also summarize novel immunoregulatory approaches that may be used to prevent graft rejection in high-risk corneal transplantation.

  3. Abundances of Cloud-Related Gases in the Venus Atmosphere as Inferred from Observed Radio Opacity.

    Science.gov (United States)

    Steffes, Paul Gregory

    1982-03-01

    Various radio-analytical techniques have detected microwave opacity in the middle atmosphere of Venus, well above the main carbon dioxide opacity of the lower atmosphere. Consideration of the amount, distribution, and effects of the constituents which produce the main cloud layer at about 50 km altitude, indicate that such cloud-related gases, especially sulfuric acid vapor, are the predominant source of the observed opacity of the middle atmosphere. Theoretical and laboratory studies were made of the microwave absorption from three cloud-related gases: sulfur dioxide, sulfur trioxide, and gaseous sulfuric acid. While the measured absorption from sulfur dioxide under conditions for the middle atmosphere of Venus was found to be 50% larger than suggested by theory, the amount of sulfur dioxide required to explain the opacity as measured by radio occultation exceeded the abundance measured in situ by atmospheric probes, suggesting that there must be another important source of opacity. Sulfur trioxide was tested and found to be relatively transparent, but laboratory measurements of the microwave opacity of gaseous sulfuric acid under Venus atmospheric conditions indicate that it is an exceptionally strong absorber with absorptivity that has a surprisingly weak dependence on radio frequency. Initial theoretical studies also indicate a large absorptivity and weak frequency dependence, although the measured opacity is larger than the computed value, presumably due to deviations from Van Vleck-Weisskopf theory. The absorbing characteristics of sulfuric acid vapor appear to reconcile past inconsistencies among measurements and deductions concerning the constituents of the atmosphere of Venus, and radio occultation, radar reflection, and radio emission measurements of its opacity. The results of the current studies are used with previous data for the absorptivity of water vapor and carbon dioxide to model relative contributions to opacity as a function of height, in a way

  4. The Impact of Enhanced Iron Opacity on Massive Star Pulsations: Updated Instability Strips

    CERN Document Server

    Moravveji, Ehsan

    2015-01-01

    Recently, Bailey et al. (2015) made a direct measurement of the Iron opacity at the physical conditions of the solar tachocline. They found that the wavelength-integrated Iron opacity is roughly 75% higher that what the OP and OPAL models predict. Here, we compute new opacity tables with enhanced Iron and Nickel contributions to the Rosseland mean opacity by 75% each, and compute three dense MESA grids of evolutionary models for Galactic O- and B-type stars covering from 2.5 to 25 M$_\\odot$ from ZAMS until $T_{\\rm eff}=10\\,000$ K after the core hydrogen exhaustion. We carry out non-adiabatic mode stability analysis with GYRE, and update the extension of the instability strips of heat-driven p- and g-mode pulsators, and the hybrid pulsating SPB - $\\beta$ Cep stars. We compare the position of two confirmed late O-type $\\beta$ Cep and eight confirmed hybrid B-type pulsators with the new instability domains, and justify that $\\sim$75% enhancement, only in Iron opacity, is sufficient to consistently reproduce the ...

  5. Tamper asymmetry and its effect on transmission for x-ray driven opacity simulations

    Science.gov (United States)

    Morris, H. E.; Tregillis, I. L.; Hoffman, N. M.; Sherrill, M. E.; Fontes, C. J.; Marshall, A. J.; Urbatsch, T. J.; Bradley, P. A.

    2017-09-01

    This paper reports on synthetic transmission results from Lasnex [Zimmerman and Kruer, Comments Plasma Phys. 2, 51 (1975)] radiation-hydrodynamics simulations of opacity experiments carried out at Sandia National Laboratories' recently upgraded ZR facility. The focus is on experiments utilizing disk targets composed of a half-moon Fe/Mg mixture tamped on either end with 10-μm CH and an additional 35-μm beryllium tamper accessory on the end facing the spectrometer. Five x-ray sources with peak power ranging from 10 to 24 TW were used in the simulations to heat and backlight the opacity target. The dominant effect is that the beryllium behind the Fe/Mg mixture is denser and more opaque than the beryllium unshielded by metal during the times of greatest importance for the transmission measurement for all drives. This causes the simulated transmission to be lower than expected, and this is most pronounced for the case using the lowest drive power. While beryllium has a low opacity, its areal density is sufficiently high such that the expected reduction of the measured transmission is significant. This situation leads to an overestimate of iron opacity by 10%-215% for a photon energy range of 975-1775 eV for the 10-TW case. It is shown that if the tamper conditions are known, the transmission through each component of the target can be calculated and the resulting opacity can be corrected.

  6. Iron and Nickel spectral opacity calculations in conditions relevant for pulsating stellar envelopes and experiments

    Directory of Open Access Journals (Sweden)

    Gilles D.

    2013-11-01

    Full Text Available Seismology of stars is strongly developing. To address this question we have formed an international collaboration, OPAC, to perform specific experimental measurements, compare opacity calculations, and improve the opacity calculations in stellar codes [1]. We consider the following opacity codes: SCO, CASSANDRA, STA, OPAS, LEDCOP, OP, SCO-RCG. Their comparison has shown large differences for Fe and Ni in equivalent conditions of envelopes of type II supernova precursors, temperatures between 15 and 40 eV and densities of a few mg/cm3 [2–4]. LEDCOP, OPAS, SCO-RCG structure codes and STA give similar results and differ from OP ones for the lower temperatures and for spectral interval values [3]. In this work we discuss the role of Configuration Interaction (CI and the influence of the number of used configurations. We present and include in the opacity code comparisons new HULLAC-v9 calculations [5, 6] that include full CI. To illustrate the importance of this effect we compare different CI approximations (modes available in HULLAC-v9 [7]. These results are compared to previous predictions and to experimental data. Differences with OP results are discussed.

  7. Low-temperature gas opacity - AESOPUS: a versatile and quick computational tool

    CERN Document Server

    Marigo, Paola

    2009-01-01

    We introduce a new tool - AESOPUS: Accurate Equation of State and OPacity Utility Software - for computing the equation of state and the Rosseland mean (RM) opacities of matter in the ideal gas phase. Results are given as a function of one pair of state variables, (i.e. temperature T in the range 3.2 <= log(T) <= 4.5, and parameter R= rho/(T/10^6 K)^3 in the range -8 <= log(R) <= 1), and arbitrary chemical mixture. The chemistry is presently solved for about 800 species, consisting of almost 300 atomic and 500 molecular species. The gas opacities account for many continuum and discrete sources, including atomic opacities, molecular absorption bands, and collision-induced absorption. Several tests made on AESOPUS have proved that the new opacity tool is accurate in the results,flexible in the management of the input prescriptions, and agile in terms of computational time requirement. We set up a web-interface (http://stev.oapd.inaf.it/aesopus) which enables the user to compute and shortly retrieve ...

  8. Simultaneous unfolding of compression and opacity from time-resolved radiography

    Science.gov (United States)

    Swift, D.; Hawreliak, J.; Rothman, S.; Kritcher, A.; Doeppner, T.; Collins, G.; Gaffney, J.; Rose, S.

    2013-06-01

    Radiographs of symmetric objects can be analyzed to give the spatial variation of attenuation, as in the Abel inversion of an axisymmetric object. If the opacity is known, the mass density can be derived from the attenuation. The space- and time-variation of density is needed to make equation of state (EOS) measurements by radiography, e.g. by measuring the speed and compression of a shock. However, in our experiments using hohlraum drive at the National Ignition Facility (NIF) to perform EOS measurements at gigabar pressures with spherically-converging shocks, the opacity may vary by an order of magnitude because of ionization. We have developed a new algorithm to simultaneously deduce the compression and opacity of the sample given time-resolved radiographs with a Lagrangian location behind the shock, such as the edge of the sample. This approach relies on spatial integration to deduce the opacity in the region just behind the shock from the difference between the known and apparent mass. We assume that the change in opacity is dominated by shock-heating, so that subsequent variations, as shocked material is either released or compressed further, are negligible or can be accounted for by a model. We used this algorithm to analyze our NIF data on the Hugoniot of CH at 10-40 TPa. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.

  9. The significance of recurrent lung opacities in neonates on surfactant treatment for respiratory distress syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Odita, J.C. [Dept. of Radiology, Louisiana State Univ. Health Sciences Center, Shreveport (United States)

    2001-02-01

    Purpose. To determine the significance of recurrent opacities in chest radiographs of neonates on surfactant therapy for respiratory distress syndrome (RDS) after an initial period of improvement. Materials and methods. Serial pre- and post-surfactant chest radiographs on 94 preterm infants with RDS were analyzed and the pattern of chest radiographic response was classified as (a) clear, (b) recurrent opacities, and (c) no response. Their clinical characteristics were also recorded. Results. In 34 infants the RDS changes cleared within 3 days. 31 infants developed lung opacities within 10 days after an initial period of improvement. Twenty-nine infants failed to respond to the surfactant. The corresponding mean birth weights for the three groups were 1.74, 1.19, and 0.76 kg and the mean gestation ages 32.6, 27.7, and 25.4 weeks. The incidence of bronchopulmonary dysplasia (BPD) was highest among the slumping infants (72. % vs 50 % in no responders, P < 0.001) Conclusions. The pattern of chest radiographic response is primarily affected by gestation age and birth weight. Recurrent lung opacity after an initial positive response to surfactant therapy may be caused by such factors as edema from barotrauma and patent ductus arteriosus. Infants with intraventricular hemorrhage may demonstrate neurogenic edema. Other contributory factors include pneumonia and abnormal consumption of surfactant. Recurrent lung opacities after surfactant may be a predictor of chronic lung disease in the preterm infant. (orig.)

  10. Iron and Nickel spectral opacity calculations in conditions relevant for pulsating stellar envelopes and experiments

    CERN Document Server

    Gilles, D; Busquet, M; Thais, F; Loisel, G; Piau, L; Ducret, J E; Blenski, T; Blancard, C; Cossé, P; Faussurier, G; Gilleron, F; Pain, J C; Porcherot, Q; Guzik, J A; Kilcrease, D P; Magee, N H; Harris, J; Bastiani-Ceccotti, S; Delahaye, F; Zeippen, C J

    2012-01-01

    Seismology of stars is strongly developing. To address this question we have formed an international collaboration OPAC to perform specific experimental measurements, compare opacity calculations and improve the opacity calculations in the stellar codes [1]. We consider the following opacity codes: SCO, CASSANDRA, STA, OPAS, LEDCOP, OP, SCO-RCG. Their comparison has shown large differences for Fe and Ni in equivalent conditions of envelopes of type II supernova precursors, temperatures between 15 and 40 eV and densities of a few mg/cm3 [2, 3, 4]. LEDCOP, OPAS, SCO-RCG structure codes and STA give similar results and differ from OP ones for the lower temperatures and for spectral interval values [3]. In this work we discuss the role of Configuration Interaction (CI) and the influence of the number of used configurations. We present and include in the opacity code comparisons new HULLAC-v9 calculations [5, 6] that include full CI. To illustrate the importance of this effect we compare different CI approximation...

  11. Atomic structure considerations for the low-temperature opacity of Sn

    Science.gov (United States)

    Colgan, J.; Kilcrease, D. P.; Abdallah, J.; Sherrill, M. E.; Fontes, C. J.; Hakel, P.; Armstrong, G. S. J.

    2017-06-01

    We have begun a preliminary investigation into the opacity of Sn at low temperatures (emissivity and opacity of Sn is a crucial factor in determining the utility of Sn in EUV lithography, with numerous industrial implications. To this end, we have been exploring the accuracy of some approximations used in opacity models for the relevant ion stages of Sn (neutral through ∼ 18 times ionized). We find that the use of intermediate-coupling, as compared to full configuration-interaction, is not adequate to obtain accurate line positions of the important bound-bound transitions in Sn. One requires full configuration-interaction to properly describe the strong mixing between the various n = 4 sub-shells that give rise to the Δ n = 0 transitions that dominate the opacity spectrum at low temperatures. Since calculations that include full configuration-interaction for large numbers of configurations quickly become computationally prohibitive, we have explored hybrid calculations, in which full configuration-interaction is retained for the most important transitions, while intermediate-coupling is employed for all other transitions. After extensive exploration of the atomic structure properties, local-thermodynamic-equilibrium (LTE) opacities are generated using the ATOMIC code at selected temperatures and densities and compared to experiment.

  12. EXPERIMENTAL STUDY ON THE CORNEAL ENDOTHELIUM OF TRAUMATIC CATARACT

    Institute of Scientific and Technical Information of China (English)

    1991-01-01

    The cell morphology of corneal endothelium in 84 mice with experimental traumatic cataract was investigated with stained corneal buttons. In the experimental group, the boundaries between adjacent corneal endothelial cells were significantly distorted, some cell boundaries manifested degenerative changes that led to coalescence of the cells. The mean density and mean area of endothelial cells of the controls showed significant difference from those of the experimental group during the 12 weeks of observ...

  13. Corneal Ectasis among Wrestlers: Report of Two Cases

    OpenAIRE

    Mohammad Ali Zare Mehrjardi; Hadi Zare Mehrjardi; Abasali Gaeeni; Elham Ashrafi; Homa Naderifar

    2014-01-01

    Report keratoconus in two patients with a long history of wrestling without any risk factor for corneal ectasia and reviewing the possible pathogenesis. To confirm suspicion of keratoconus, corneal topography was performed using scanning slit topography system and Orbscan. In two wrestlers with the complaint of visual loss in their eyes and IOP raising, corneal topography was performed and development of keratoconus (KCN) was detected. Athletes involved in sports with high strenuous exercises...

  14. A brief history of corneal transplantation: From ancient to modern

    OpenAIRE

    Alexandra X Crawford; Patel, Dipika V.; Charles NJ McGhee

    2013-01-01

    This review highlights many of the fundamental concepts and events in the development of corneal transplantation - from ancient times to modern. Tales of eye, limb, and even heart transplantation appear in ancient and medieval texts; however, in the scientific sense, the original concepts of corneal surgery date back to the Greek physician Galen (130-200 AD). Although proposals to provide improved corneal clarity by surgical interventions, including keratoprostheses, were better developed by ...

  15. Retinal evaluation and treatment after refractive corneal surgery.

    Science.gov (United States)

    Swinger, C A; Kraushar, M F

    1985-08-01

    Refractive corneal surgery (a collective term used to describe a variety of surgical procedures that alter the refractive status of the eye through the surgical modification of corneal curvature) shows promise for use in situations where current methods of optical correction do not meet the patient's needs. This article reviews our experiences with the retinal evaluation of patients who have undergone corneal refractive surgery and offers recommendations for the treatment of retinal pathology after such surgery.

  16. Organism Isolation in Corneal Ulcer- Utility of Different Techniques

    OpenAIRE

    M Thapa; A.K. Sharma; D.N. Shah; S KC; Shrestha, S.

    2012-01-01

    Introduction: Various techniques are available for isolation of microorganism in cases of microbial keratitis including conventional methods of scraping, re-scraping inoculation in different media and corneal biopsy. Methods: This was a cross sectional descriptive study conducted from February 2002 to July 2003. A total of 161 eyes of corneal ulcers were evaluated with scraping inoculation. Re-scraping and corneal biopsy were performed in those cases which did not grow any organism in t...

  17. New null screen design for corneal topography

    Science.gov (United States)

    Campos-García, Manuel; Estrada-Molina, Amilcar; Díaz-Uribe, Rufino

    2011-09-01

    In this work we report the design of a null screen for corneal topography. Here we assume that the corneal surface is an ellipsoid with a diameter of 12 mm and a curvature radius of 7.8 mm. To avoid the difficulties in the alignment of the test system due to the face contour (eyebrows, nose, or eyelids), we design a conical null-screen with spots (similar to ellipses) drawn on it in such a way that its image, which is formed by reflection on the test surface, becomes an exact radial array of circular spots if the surface is perfect. Additionally, we performed a numerical simulation introducing Gaussian random errors in the coordinates of the centroids of the spots on the image plane, and in the coordinates of the sources (spots on the null-screen) in order to obtain the conical null-screen that reduces the error in the evaluation of the topography.

  18. Corneal Chromoblastomycosis Caused by Fonsecaea pedrosoi

    Directory of Open Access Journals (Sweden)

    Winai Chaidaroon

    2015-02-01

    Full Text Available Purpose: To report 2 unusual cases of fungal keratitis due to Fonsecaea pedrosoi. Methods: Two patients were diagnosed with Fonsecaea pedrosoi keratitis. Their files were reviewed for predisposing factors, clinical characteristics, microbiological study, treatment, and outcome. Results: Two consecutive patients presented with brownish pigmented corneal ulcers in their eyes after sustaining eye trauma from vegetative matter. In both cases, corneal scrapings were collected for microscopic examination and culture. Dematiaceous hyphae were seen on the smears, and dark pigmented colonies grew on the culture media, identified as F. pedrosoi. Both patients were treated and cured with combined topical antifungal agents and oral itraconazole. The first patient required an amniotic membrane patch, while the second received an intracameral amphotericin B injection. Conclusions: Pigmented infiltrates can be an important diagnostic clue, but a microscopic evaluation and culture are required to obtain an accurate diagnosis of Fonsecaea keratitis. The prompt diagnosis and combined antifungal treatment can prevent morbidity associated with this fungal infection.

  19. Prevalence of corneal astigmatism before cataract surgery.

    Science.gov (United States)

    Mohammadi, Mehran; Naderan, Mohammad; Pahlevani, Rozhin; Jahanrad, Ali

    2016-12-01

    The purpose of this study was to describe and analyze the prevalence and pattern of corneal astigmatism in cataract surgery candidates. In a prospective cross-sectional study, preoperative demographics, and keratometric and refractive values of cataract surgery candidates were collected from January 2013 to December 2014. Axial length (AL) and flat and steep keratometry measurements were optically measured by a partial coherence interferometry device (IOLMaster). This study consisted of 2156 eyes of 1317 patients with a mean age of 64.92 ± 11.48 (SD) (30-88 years). The mean of AL was 23.33 ± 1.37 mm, and the mean of corneal astigmatism was 1.12 ± 1.10 diopter (D) (range 0.0-7.00), in all patients. Furthermore, the mean of flat and steep keratometry were 43.70 ± 1.70 and 44.83 ± 1.79 D, respectively. Corneal astigmatism was 1.50 D or less in 1590 eyes (73.7 %), more than 1.50 D in 566 eyes (26.2 %), 3.00 D or more in 161 eyes (7.4 %), WTR in 796 eyes (36.9 %), ATR in 1010 eyes (46.8 %), and oblique in 350 eyes (16.2 %). ATR astigmatism axis significantly increased with the increase in age. Corneal astigmatism of most cataract surgery candidates fell between 0.50 and 1.50 D. The results of our study however is confined to our demographics might provide useful data for cataract patients, surgeons, and intraocular lens manufacturers for different purposes.

  20. Corneal Neurotoxicity Due to Topical Benzalkonium Chloride

    Science.gov (United States)

    Sarkar, Joy; Chaudhary, Shweta; Namavari, Abed; Ozturk, Okan; Chang, Jin-Hong; Yco, Lisette; Sonawane, Snehal; Khanolkar, Vishakha; Hallak, Joelle; Jain, Sandeep

    2012-01-01

    Purpose. The aim of this study was to determine and characterize the effect of topical application of benzalkonium chloride (BAK) on corneal nerves in vivo and in vitro. Methods. Thy1-YFP+ neurofluorescent mouse eyes were treated topically with vehicle or BAK (0.01% or 0.1%). Wide-field stereofluorescence microscopy was performed to sequentially image the treated corneas in vivo every week for 4 weeks, and changes in stromal nerve fiber density (NFD) and aqueous tear production were determined. Whole-mount immunofluorescence staining of corneas was performed with antibodies to axonopathy marker SMI-32. Western immunoblot analyses were performed on trigeminal ganglion and corneal lysates to determine abundance of proteins associated with neurotoxicity and regeneration. Compartmental culture of trigeminal ganglion neurons was performed in Campenot devices to determine whether BAK affects neurite outgrowth. Results. BAK-treated corneas exhibited significantly reduced NFD and aqueous tear production, and increased inflammatory cell infiltration and fluorescein staining at 1 week (P < 0.05). These changes were most significant after 0.1% BAK treatment. The extent of inflammatory cell infiltration in the cornea showed a significant negative correlation with NFD. Sequential in vivo imaging of corneas showed two forms of BAK-induced neurotoxicity: reversible neurotoxicity characterized by axonopathy and recovery, and irreversible neurotoxicity characterized by nerve degeneration and regeneration. Increased abundance of beta III tubulin in corneal lysates confirmed regeneration. A dose-related significant reduction in neurites occurred after BAK addition to compartmental cultures of dissociated trigeminal ganglion cells. Although both BAK doses (0.0001% and 0.001%) reduced nerve fiber length, the reduction was significantly more with the higher dose (P < 0.001). Conclusion. Topical application of BAK to the eye causes corneal neurotoxicity, inflammation, and reduced aqueous

  1. Analysis of correlation between corneal topographical data and visual performance

    Science.gov (United States)

    Zhou, Chuanqing; Yu, Lei; Ren, Qiushi

    2007-02-01

    Purpose: To study correlation among corneal asphericity, higher-order aberrations and visual performance for eyes of virgin myopia and postoperative laser in situ keratomileusis (LASIK). Methods: There were 320 candidates 590 eyes for LASIK treatment included in this study. The mean preoperative spherical equivalence was -4.35+/-1.51D (-1.25 to -9.75), with astigmatism less than 2.5 D. Corneal topography maps and contrast sensitivity were measured and analyzed for every eye before and one year after LASIK for the analysis of corneal asphericity and wavefront aberrations. Results: Preoperatively, only 4th and 6th order aberration had significant correlation with corneal asphericity and apical radius of curvature (pcorneal asphericity (pcorneal aberrations had no significant correlation with visual acuity and area under the log contrast sensitivity (AULCSF) (P>0.05). Postoperatively, corneal aberrations still didn't have significant correlation with visual acuity (P>0.05), but had significantly negative correlation with AULCSF (PCorneal asphericity had no significant correlation with AULCSF before and after the treatment (P>0.05). Conclusions: Corneal aberrations had different correlation with corneal profile and visual performance for eyes of virgin myopia and postoperative LASIK, which may be due to changed corneal profile and limitation of metrics of corneal aberrations.

  2. Clinical correlates of common corneal neovascular diseases: a literature review

    Institute of Scientific and Technical Information of China (English)

    Nizar; Saleh; Abdelfattah; Mohamed; Amgad; Amira; A; Zayed; Hamdy; Salem; Ahmed; E; Elkhanany; Heba; Hussein; Nawal; Abd; El-Baky

    2015-01-01

    A large subset of corneal pathologies involves the formation of new vessels(neovascularization), leading to compromised visual acuity. This article aims to review the clinical causes and presentations of corneal neovascularization(CNV) by examining the mechanisms behind common CNV-related corneal pathologies, with a particular focus on herpes simplex stromal keratitis,contact lenses-induced keratitis and CNV secondary to keratoplasty. Moreover, we reviewed CNV in the context of different types of corneal transplantation and keratoprosthesis, and summarized the most relevant treatment available so far.

  3. Decreased central corneal thickness in ankylosing spondylitis.

    Science.gov (United States)

    Ortak, Huseyin; Inanır, Ahmet; Demir, Selim; Uysal, Alper; Şahin, Şafak; Sağcan, Mustafa; Önder, Yalçın; Alim, Sait; Demir, Ayşe Kevser

    2014-04-01

    Central corneal thickness and dry eye tests were evaluated in a study population consisting of 68 ankylosing spondylitis patients diagnosed according to the modified New York criteria, and 61 age-matched controls without ankylosing spondylitis. A full ophthalmological evaluation was performed on each subject. All subjects were screened for age, gender, HLA-B27, tear break-up time test, Schirmer test, and duration of disease. Central corneal thickness was measured under topical anesthesia with an ultrasonic pachymeter. The mean central corneal thickness was 537.3 ± 30.6 μm, range 462-600 μm, in ankylosing spondylitis patients, whereas it was 551.7 ± 25.2 μm, range 510-620 μm, in controls (p = 0.005). The Schirmer test result was 7.3 ± 5.9 mm for the ankylosing spondylitis patients and 11.7 ± 5.8 mm for the control group (p = 0.002). Tear break-up time was 7.3 ± 3.2 s for the ankylosing spondylitis patients and 14.0 ± 4.5 s for the control group (p ankylosing spondylitis. In addition, attention must be given to lower dry eye tests in surgical interventions such as photorefractive keratectomy and laser in situ keratomileusis in ankylosing spondylitis patients.

  4. Meretoja's Syndrome: Lattice Corneal Dystrophy, Gelsolin Type

    Science.gov (United States)

    Abreu, C.; Neves, M.; Oliveira, L.; Beirão, M.

    2017-01-01

    Lattice corneal dystrophy gelsolin type was first described in 1969 by Jouko Meretoja, a Finnish ophthalmologist. It is caused by an autosomal dominant mutation in gelsolin gene resulting in unstable protein fragments and amyloid deposition in various organs. The age of onset is usually after the third decade of life and typical diagnostic triad includes progressive bilateral facial paralysis, loose skin, and lattice corneal dystrophy. We report a case of a 53-year-old female patient referred to our Department of Ophthalmology by severe dry eye and incomplete eyelid closure. She had severe bilateral facial paresis, significant orbicularis, and perioral sagging as well as hypoesthesia of extremities and was diagnosed with Meretoja's syndrome at the age of 50, confirmed by the presence of gelsolin mutation. At our observation she had bilateral diminished tear film break-up time and Schirmer test, diffuse keratitis, corneal opacification, and neovascularization in the left eye. She was treated with preservative-free lubricants and topical cyclosporine, associated with nocturnal complete occlusion of both eyes, and underwent placement of lacrimal punctal plugs. Ocular symptoms are the first to appear and our role as ophthalmologists is essential for the diagnosis, treatment, and monitoring of ocular alterations in these patients. PMID:28250773

  5. Putative epidermal stem cell convert into corneal epithelium-like cell under corneal tissue in vitro

    Institute of Scientific and Technical Information of China (English)

    GAO Nan; CUI GuangHui; WANG ZhiChong; HUANG Bing; GE Jian; LU Rong; ZHANG KeFei; FAN ZhiGang; LU Li; PENG Zhan

    2007-01-01

    Rhesus putative epidermal stem cells are being investigated for their potential use in regenerative corneal epithelium-like cells, which may provide a practical source of autologous seed cells for the construction of bioengineered corneas. The goal of this study was to investigate the potential of epidermal stem cells for trans-differentiation into corneal epithelium-like cells. Rhesus putative epidermal stem cells were isolated by type IV collagen attachment method. Flow cytometry analysis, immunohistology and RT-PCR were conducted to identify the expression of specific markers (β1, α6 integrin, K15, K1/K10, K3/K12 and CD71) on the isolated rapid attaching cells. The isolated cells were cocultured with human corneal limbal stroma and corneal epithelial cells. After coculture, the expression of the same specific markers was evaluated in order to identify expression difference caused by the coculture conditions. K3/K12 expression was analyzed in coculture cells on day 2, 4, 6, 8 and 10. Putative epidermal stem cells in conditioned culture media were used as control. Putative epidermal stem cells were predominant in rapid attaching cells by type IV collagen attachment isolation. Before being cocultured, the rhesus putative epidermal stem cells expressed K15, α6 and β1 integrin, but no CD71, K1/K10 and K3/K12. After coculture, these cells expressed K3/K12 (a marker of corneal epithelial cells), K15 and β 1 integrin, but no K1/K10. Cells being not coculture converted into terminally differentiated cells expressing K1/K10. These results indicate that rhesus putative epidermal stem cells can trans-differentiate into corneal epithelium-like cells and, therefore, may have potential therapeutic application as autologous seed cells for the construction of bioengineered corneas.

  6. Putative epidermal stem cell convert into corneal epithelium-like cell under corneal tissue in vitro

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Rhesus putative epidermal stem cells are being investigated for their potential use in regenerative corneal epithelium-like cells, which may provide a practical source of autologous seed cells for the construction of bioengineered corneas. The goal of this study was to investigate the potential of epi-dermal stem cells for trans-differentiation into corneal epithelium-like cells. Rhesus putative epidermal stem cells were isolated by type IV collagen attachment method. Flow cytometry analysis, immuno-histology and RT-PCR were conducted to identify the expression of specific markers (β1, α6 integrin, K15, K1/K10, K3/K12 and CD71) on the isolated rapid attaching cells. The isolated cells were cocultured with human corneal limbal stroma and corneal epithelial cells. After coculture, the expression of the same specific markers was evaluated in order to identify expression difference caused by the coculture conditions. K3/K12 expression was analyzed in coculture cells on day 2, 4, 6, 8 and 10. Putative epi-dermal stem cells in conditioned culture media were used as control. Putative epidermal stem cells were predominant in rapid attaching cells by type IV collagen attachment isolation. Before being co-cultured, the rhesus putative epidermal stem cells expressed K15, α6 and β1 integrin, but no CD71, K1/K10 and K3/K12. After coculture, these cells expressed K3/K12 (a marker of corneal epithelial cells), K15 and β 1 integrin, but no K1/K10. Cells being not coculture converted into terminally differentiated cells expressing K1/K10. These results indicate that rhesus putative epidermal stem cells can trans-differentiate into corneal epithelium-like cells and, therefore, may have potential therapeutic application as autologous seed cells for the construction of bioengineered corneas.

  7. Development of new therapeutic modalities for corneal endothelial disease focused on the proliferation of corneal endothelial cells using animal models.

    Science.gov (United States)

    Koizumi, Noriko; Okumura, Naoki; Kinoshita, Shigeru

    2012-02-01

    This review describes our recent attempts to develop new therapeutic modalities for corneal endothelial disease using animal models including non-human primate model in which the proliferative ability of corneal endothelial cells is severely limited, as is the case in humans. First, we describe our attempt to develop new surgical treatments using cultivated corneal endothelial cells for advanced corneal endothelial dysfunction. It includes two different approaches; a "corneal endothelial cell sheet transplantation" with cells grown on a type-I collagen carrier, and a "cell-injection therapy" combined with the application of Rho-kinase (ROCK) inhibitor. Recently, it was reported that the selective ROCK inhibitor, Y-27632, promotes cell adhesion and proliferation and inhibits the apoptosis of primate corneal endothelial cells in culture. When cultivated corneal endothelial cells were injected into the anterior chamber of animal eyes in the presence of ROCK inhibitor, endothelial cell adhesion was promoted and the cells achieved a high cell density and a morphology similar to corneal endothelial cells in vivo. We are also trying to develop a novel medical treatment for the early phase of corneal endothelial disease by the use of ROCK inhibitor eye drops. In rabbit and monkey experiments using partial endothelial dysfunction models, corneal endothelial wound healing was accelerated by the topical application of ROCK inhibitor to the ocular surface, and resulted in the regeneration of a corneal endothelial monolayer with a high endothelial cell density. We are now trying to advance the clinical application of these new therapies for patients with corneal endothelial dysfunction.

  8. Capsule implosions for continuum x-ray backlighting of opacity samples at the National Ignition Facility

    Science.gov (United States)

    Opachich, Y. P.; Heeter, R. F.; Barrios, M. A.; Garcia, E. M.; Craxton, R. S.; King, J. A.; Liedahl, D. A.; McKenty, P. W.; Schneider, M. B.; May, M. J.; Zhang, R.; Ross, P. W.; Kline, J. L.; Moore, A. S.; Weaver, J. L.; Flippo, K. A.; Perry, T. S.

    2017-06-01

    Direct drive implosions of plastic capsules have been performed at the National Ignition Facility to provide a broad-spectrum (500-2000 eV) X-ray continuum source for X-ray transmission spectroscopy. The source was developed for the high-temperature plasma opacity experimental platform. Initial experiments using 2.0 mm diameter polyalpha-methyl styrene capsules with ˜20 μm thickness have been performed. X-ray yields of up to ˜1 kJ/sr have been measured using the Dante multichannel diode array. The backlighter source size was measured to be ˜100 μm FWHM, with ˜350 ps pulse duration during the peak emission stage. Results are used to simulate transmission spectra for a hypothetical iron opacity sample at 150 eV, enabling the derivation of photometrics requirements for future opacity experiments.

  9. A consistent approach for mixed detailed and statistical calculation of opacities in hot plasmas

    CERN Document Server

    Porcherot, Quentin; Gilleron, Franck; Blenski, Thomas

    2011-01-01

    Absorption and emission spectra of plasmas with multicharged-ions contain transition arrays with a huge number of coalescent electric-dipole (E1) lines, which are well suited for treatment by the unresolved transition array and derivative methods. But, some transition arrays show detailed features whose description requires diagonalization of the Hamiltonian matrix. We developed a hybrid opacity code, called SCORCG, which combines statistical approaches with fine-structure calculations consistently. Data required for the computation of detailed transition arrays (atomic configurations and atomic radial integrals) are calculated by the super-configuration code SCO (Super-Configuration Opacity), which provides an accurate description of the plasma screening effects on the wave-functions. Level energies as well as position and strength of spectral lines are computed by an adapted RCG routine of R. D. Cowan. The resulting code provides opacities for hot plasmas and can handle mid-Z elements. The code is also a po...

  10. Atomic and Molecular Opacities for Brown Dwarf and Giant Planet Atmospheres

    CERN Document Server

    Sharp, C M; Sharp, Christopher M.; Burrows, Adam

    2006-01-01

    We present a comprehensive description of the theory and practice of opacity calculations from the infrared to the ultraviolet needed to generate models of the atmospheres of brown dwarfs and extrasolar giant planets. Methods for using existing line lists and spectroscopic databases in disparate formats are presented and plots of the resulting absorptive opacities versus wavelength for the most important molecules and atoms at representative temperature/pressure points are provided. Electronic, ro-vibrational, bound-free, bound-bound, free-free, and collision-induced transitions and monochromatic opacities are derived, discussed, and analyzed. The species addressed include the alkali metals, iron, heavy metal oxides, metal hydrides, $H_2$, $H_2O$, $CH_4$, $CO$, $NH_3$, $H_2S$, $PH_3$, and representative grains. [Abridged

  11. Smoke opacity in agricultural tractor in function of interior and metropolitano diesel mixture in mamona biodiesel

    Energy Technology Data Exchange (ETDEWEB)

    Tabile, Rubens Andre [Universidade de Sao Paulo (EESC/USP), Sao Carlos, SP (Brazil). Escola de Engenharia; Lopes, Afonso; Camara, Felipe Thomas da; Grotta, Danilo Cesar Checchio; Furlani, Carlos Eduardo Angeli [Universidade Estadual Paulista (DER/UNESP), Jaboticabal, SP (Brazil). Dept. de Engenharia Rural

    2008-07-01

    The great demand for energy sources by production systems allied to scarcity of fossil fuels has motivated the development and production of biodiesel, which is a fuel produced from renewable sources. Given that, the aim of this study was to compare smoke opacity of an agricultural tractor engine, working with metropolitano and interior diesel mixed to mamona biodiesel, in seven proportions. The tests were conducted in the Departamento de Engenharia Rural of UNESP/Jaboticabal - SP. The results showed that the diesel type did influence opacity of smoke, and metropolitano diesel showed best quality. It was also observed that, as biodiesel proportion increased, smoke opacity decreased until B75, turning to increase to B100. (author)

  12. The Hybrid Detailed / Statistical Opacity Code SCO-RCG: New Developments and Applications

    CERN Document Server

    Pain, Jean-Christophe; Porcherot, Quentin; Blenski, Thomas

    2013-01-01

    We present the hybrid opacity code SCO-RCG which combines statistical approaches with fine-structure calculations. Radial integrals needed for the computation of detailed transition arrays are calculated by the code SCO (Super-configuration Code for Opacity), which calculates atomic structure at finite temperature and density, taking into account plasma effects on the wave-functions. Levels and spectral lines are then computed by an adapted RCG routine of R. D. Cowan. SCO-RCG now includes the Partially Resolved Transition Array model, which allows one to replace a complex transition array by a small-scale detailed calculation preserving energy and variance of the genuine transition array and yielding improved high-order moments. An approximate method for studying the impact of strong magnetic field on opacity and emissivity was also recently implemented.

  13. Radio-opacity of commonly consumed bony fish in kelantan, malaysia.

    Science.gov (United States)

    Irfan, M; Ahmad Helmy, A K; Wan Shah Jihan, W D

    2012-10-01

    Fish is one of the major sources of protein among Malaysians. This has made incidents of fish bones lodged in the throat fairly common clinical problems. Plain radiograph, which is the first line of imaging in such cases, has been reported to have low sensitivity. Besides the location, the degree of radio-opacity of the bone is another important factor and is species dependent. This study was undertaken to determine the radio-opacity of bones from commonly consumed fish in Malaysia. A total of 15 types of fish were identified, six of them were opaque even when embedded and three were visualized in the simulated airway. In terms of radio-opacity, the commonly consumed fish in Malaysia possessed opaque bones and this fact can help doctors identify the location of the foreign body in the throat.

  14. The optical imaging of tarantula hair corneal injury: One case report and review of the literature.

    Science.gov (United States)

    Hu, Yuedong; Xu, Yuanyuan

    2017-09-01

    Tarantulas belonging to the Theraphosidae family are more and more popular as family pets. Ocular injuries caused by tarantulas are reported in several articles. We hereby report the first known case of ocular injury caused by a tarantula in China and observed by anterior segment optical coherence tomography (AS-OCT). A 22-year-old girl was referred to our hospital with one-week history of red and irritated left eye after she grabbed her molting Chilean Rose Tarantula. Her best-corrected visual acuity was 20/20 on both eyes. Her left eyelid was slightly red and edema. Slit-lamp examination found that more than a dozen of microscopic barbed hairs embedded into the cornea. AS-OCT showed that barbed hairs embedded in the cornea in different direction and the length of the hairs ranged from 173μm to 395μm. The anterior chamber was quiet with normal fundus and intraocular pressure. Topical steroid treatment was prescribed and the response was good. No corneal opacity or intraocular inflammation was observed after topical steroid treatment for one month. As exotic pets become more and more popular, the importance of wearing ocular protection when handling tarantulas should be emphasized when they are sold. Tarantulas are unsuitable pet for children. When a patient presents with an unusual red eye, pet-keeping history, spiders included, should be asked. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Manifestaciones corneales en las enfermedades sistémicas Corneal manifestations in systemic diseases

    OpenAIRE

    J. Zarranz-Ventura; E. De Nova; Moreno-Montañés, J

    2008-01-01

    Un gran número de enfermedades sistémicas presentan manifestaciones corneales dentro de su espectro de enfermedad. El estudio detallado de todos los cuadros que asocian patología corneal resulta inabarcable, por ello se presentan las enfermedades más prevalentes o características. Este estudio contempla las enfermedades pulmonares y conectivopatías (colagenosis, enfermedades reumatológicas y enfermedades inflamatorias idiopáticas), las enfermedades dermatológicas, cardiovasculares, hematológi...

  16. Corneal tissue welding with infrared laser irradiation after clear corneal incision.

    Science.gov (United States)

    Rasier, Rfat; Ozeren, Mediha; Artunay, Ozgür; Bahçecioğlu, Halil; Seçkin, Ismail; Kalaycoğlu, Hamit; Kurt, Adnan; Sennaroğlu, Alphan; Gülsoy, Murat

    2010-09-01

    The aim of this study was to investigate the potential of infrared lasers for corneal welding to seal corneal cuts done in an experimental animal model. Full-thickness corneal cuts on freshly enucleated bovine eyes were irradiated with infrared (809-nm diode, 980-nm diode, 1070-nm YLF, and 1980-nm Tm:YAP) lasers to get immediate laser welding. An 809-nm laser was used with the topical application of indocyanine green to enhance the photothermal interaction at the weld site. In total, 60 bovine eyes were used in this study; 40 eyes were used in the first part of the study for the determination of optimal welding parameters (15 eyes were excluded because of macroscopic carbonization, opacification, or corneal shrinkage; 2 eyes were used for control), and 20 eyes were used for further investigation of more promising lasers (YLF and Tm:YAP). Laser wavelength, irradiating power, exposure time, and spot size were the dose parameters, and optimal dose for immediate closure with minimal thermal damage was estimated through histological examination of welded samples. In the first part of the study, results showed that none of the applications was satisfactory. Full-thickness success rates were 28% (2 of 7) for 809-nm and for 980-nm diode lasers and 67% (2 of 3) for 1070-nm YLF and (4 of 6) for 1980-nm Tm:YAP lasers. In the second part of the study, YLF and Tm:YAP lasers were investigated with bigger sample size. Results were not conclusive but promising again. Five corneal incisions were full-thickness welded out of 10 corneas with 1070-nm laser, and 4 corneal incisions were partially welded out of 10 corneas with 1980-nm laser in the second part of the study. Results showed that noteworthy corneal welding could be obtained with 1070-nm YLF laser and 1980-nm Tm:YAP laser wavelengths. Furthermore, in vitro and in vivo studies will shed light on the potential usage of corneal laser welding technique.

  17. Corneal layer plate removal with Fluconazole injected corneal stroma and autologous conjunctival transplantation for keratomycosis

    Directory of Open Access Journals (Sweden)

    Li-Dong Yang

    2013-08-01

    Full Text Available AIM: To investigate the clinical effect of corneal layer plate removal with Fluconazole injected corneal stroma and autologous conjunctival transplantation for keratomycosis.METHODS: There were 168 cases suffered keratomycosis that the focus located shallow of the cornea and was not obvious to drug, who registered in our hospital from March 2005 to June 2010. In surgery we removed plate layer to cormea clear, the region was greater than focus for 0.5mm,then we injected fluconazole which is 2g/L density in corneal stroma to make the edema area greater than Removal of area for 0.5mm. At last we took pedicle conjunctival flap to cover the plant bed by continuous suture. Postoperative day use drug to drop eye and to observe that whether recurrent of the keratomycosis and how was the edema degrade, the blood supply of conjunctival graft pieces, how about the stimulating signs of the surgery eye, the vision.RESULTS: The improvement rate was 96.2% after surgery for seven days and the cure rate was 95.5% after surgery for one months. We found in 157 eyes accepted trigeminy surgery there were 6 eyes recurrence and the recurrence rate was 3.8%. The mean time of corneal stromal edema faded away was 13.4 hours. After surgery for one month there were 39 eyes(24.8%whose vision removed than preoperative, there were 91 eyes(58.0%whose vision were same as preoperative and there were 27 eyes(17.2%whose vision lower than preoperative. In these operations the loss ratio of corneal endothelium was from 0%-8%, the mean was 2.9%. The irritative symptoms postoperative were mild for 87%, moderate for 10% and severe for 3%. By this surgery the mean length of stay was 7.3 days so the mean hospitalization expenses only were 2160 RMB. Three months after surgery, 4 cases were slight corneal ectasia.CONCLUSION: This operation combined corneal layer plate removal, Fluconazole injected corneal stroma and autologous conjunctival transplantation for keratomycosis which was in

  18. Sound speed and oscillation frequencies for a solar model evolved with Los Alamos ATOMIC opacities

    Science.gov (United States)

    Guzik, Joyce Ann; Fontes, Christopher; Walczak, Przemyslaw; Wood, Suzannah R.; Mussack, Katie

    2015-08-01

    Los Alamos has calculated a new generation of radiative opacities for elements with atomic number Z=1-30 with improved physics input, updated atomic data, and finer temperature grid to replace the Los Alamos LEDCOP opacities released in the year 2000. We calculate the evolution of a standard solar model including these new opacities, and compare with a model evolved using the Lawrence Livermore National Laboratory OPAL opacities released about 1996. We use the solar abundance mixture of Asplund, Grevesse, Sauval, and Scott (2009), including 2015 updates. The Los Alamos ATOMIC opacities (Colgan et al. 2013a,b) are somewhat higher than those of OPAL for temperatures and densities near the base of the solar convection zone. We compare the calculated nonadiabatic solar oscillation frequencies and solar interior sound speed to observed frequencies and helioseismic inferences. We discuss the potential for increased opacities to partially mitigate the ‘solar abundance problem’.References:J. Colgan, D.P. Kilcrease, N.H. Magee, Jr., G.S.J. Armstrong, J. Abdallah, Jr., M.E. Sherrill, C.J. Fontes, H.L. Zhang and P. Hakel, Eighth International Conference on Atomic and Molecular Data and their Applications: ICAMDATA, Gaithersburg, MD 2012, AIP Conf. Proc. No. 1545, (AIP, New York, 2013a), pp. 17-26.J. Colgan, D.P. Kilcrease, N.H. Magee, Jr, G.S.J. Armstrong, J. Abdallah, Jr., M.E. Sherrill, C.J. Fontes, H.L. Zhang and P. Hakel, High Energy Density Physics 9, 369 (2013b).

  19. Determining Visible Opacity of Emissions Using the Digital Opacity Compliance System II: Look Out EPA Method 9, Here Comes the Digital Equivalent (Finally)

    Science.gov (United States)

    2010-06-16

    Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 2 TECHNICAL APROACH • DoD Recognition of the Costs and Subjectivity of Method 9 Monitoring...Image Capture Induction Analysis Report Interface XML Service Form Print TECHNICAL APROACH •Automate Method 9 Opacity Readings •Provide Compliance...Background = JPG EXIF Example Images From a Safe Distance Capture The Plume and Background TECHNICAL APROACH 6 Induction • Registration Method • Minimization

  20. Metal Hydride and Alkali Halide Opacities in Extrasolar Giant Planets and Cool Stellar Atmospheres

    Science.gov (United States)

    Weck, Philippe F.; Stancil, Phillip C.; Kirby, Kate; Schweitzer, Andreas; Hauschildt, Peter H.

    2006-01-01

    The lack of accurate and complete molecular line and continuum opacity data has been a serious limitation to developing atmospheric models of cool stars and Extrasolar Giant Planets (EGPs). We report our recent calculations of molecular opacities resulting from the presence of metal hydrides and alkali halides. The resulting data have been included in the PHOENIX stellar atmosphere code (Hauschildt & Baron 1999). The new models, calculated using spherical geometry for all gravities considered, also incorporate our latest database of nearly 670 million molecular lines, and updated equations of state.

  1. Complex asteroseismology of the hybrid B-type pulsator $\\gamma$ Pegasi: a test of stellar opacities

    CERN Document Server

    Walczak, Przemysław

    2010-01-01

    Using the updated oscillation spectrum of $\\gamma$ Pegasi, we construct a set of seismic models which reproduce two pulsational frequencies corresponding to the $\\ell=0$, p$_1$ and $\\ell=1$, g$_1$ modes. Then, we single out models which reproduce other well identified modes. Finally, we extend our seismic modelling by a requirement of fitting also values of the complex, nonadiabatic parameter $f$ associated to each mode frequency. Such complex asteroseismology of the B-type pulsators provides a unique test of stellar metallicity and opacities. In contrast to our previous studies, results for $\\gamma$ Peg indicate that both opacity tables, OPAL and OP, are equally preferred.

  2. QIKMIX: a quick-turnaround computer program for computing opacities of mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Abdallah, J. Jr.; Huebner, W.F.

    1979-05-01

    QIKMIX is a quick-turnaround computer code developed to compute the radiative Rosseland mean opacity of specified mixtures at specified temperature and density points. The QIKLIB data base, which QIKMIX uses, has been derived from the OPLIB library. For most mixtures, QIKMIX can compute opacities over a temperature range of 50 to 25,000 eV in less than 1 min of CDC 7600 computer time. The purpose of this report is to discuss the QIKLIB data base and the operation of the QIKMIX code.

  3. Photoperiodic regime influences onset of lens opacities in a non-human primate

    Directory of Open Access Journals (Sweden)

    Marko Dubicanac

    2017-05-01

    Full Text Available Background Opacities of the lens are typical age-related phenomena which have a high influence on photoreception and consequently circadian rhythm. In mouse lemurs, a small bodied non-human primate, a high incidence (more than 50% when >seven years of cataracts has been previously described during aging. Previous studies showed that photoperiodically induced accelerated annual rhythms alter some of mouse lemurs’ life history traits. Whether a modification of photoperiod also affects the onset of age dependent lens opacities has not been investigated so far. The aim of this study was therefore to characterise the type of opacity and the mouse lemurs’ age at its onset in two colonies with different photoperiodic regimen. Methods Two of the largest mouse lemur colonies in Europe were investigated: Colony 1 having a natural annual photoperiodic regime and Colony 2 with an induced accelerated annual cycle. A slit-lamp was used to determine opacities in the lens. Furthermore, a subset of all animals which showed no opacities in the lens nucleus in the first examination but developed first changes in the following examination were further examined to estimate the age at onset of opacities. In total, 387 animals were examined and 57 represented the subset for age at onset estimation. Results The first and most commonly observable opacity in the lens was nuclear sclerosis. Mouse lemurs from Colony 1 showed a delayed onset of nuclear sclerosis compared to mouse lemurs from Colony 2 (4.35 ± 1.50 years vs. 2.75 ± 0.99 years. For colony 1, the chronological age was equivalent to the number of seasonal cycles experienced by the mouse lemurs. For colony 2, in which seasonal cycles were accelerated by a factor of 1.5, mouse lemurs had experienced 4.13 ± 1.50 seasonal cycles in 2.75 ± 0.99 chronological years. Discussion Our study showed clear differences in age at the onset of nuclear sclerosis formation between lemurs kept under different

  4. Corneal donations in South Africa: A 15-year review.

    Science.gov (United States)

    York, Nicholas J; Tinley, Christopher

    2017-07-28

    Corneal pathology is one of the leading causes of preventable blindness in South Africa (SA). A corneal transplant can restore or significantly improve vision in most cases. However, in SA there is a gross shortage of corneal tissue available to ophthalmologists. Little has been published describing the magnitude of the problem. To describe trends in the number of corneal donors per year in SA, the number of corneal transplants performed each year, the origin of donors, the allocation of corneas to the public or private sector, and the demographics of donors. This was a retrospective review of all corneal donations to SA eye banks over the 15-year period 1 January 2002 - 31 December 2016. There was a progressive year-on-year decline in corneal donors over the study period, from 565 per year in 2002 to 89 in 2016. As a direct result, there has been an 85.5% decrease in the number of corneal transplants performed per year using locally donated corneas, from 1 049 in 2002 to 152 in 2016. Of the donors, 48.8% originated from mortuaries, 39.0% from private hospitals and 12.2% from government hospitals; donors from mortuaries showed the most significant decline over the 15-year period, decreasing by 94.8%. Of donated corneas, 79.3% were allocated to the private sector and 21.7% to the public sector. Males comprised 69.1% of donors, while 77.2% were white, 14.0% coloured, 6.3% black and 2.5% Indian/Asian. Donor age demonstrated a bimodal peak at 25 and 55 years. The number of corneal donations in SA has declined markedly, causing the burden of corneal disease requiring transplantation to rise steadily. Population groups with a low donor rate may have cultural and other objections to corneal donation, which should be a major focus of future research and initiatives aimed at reversing the current trends.

  5. Comparison of corneal sensitivity, tear function and corneal staining following laser in situ keratomileusis with two femtosecond laser platforms

    Directory of Open Access Journals (Sweden)

    Petznick A

    2013-03-01

    Full Text Available Andrea Petznick,1 Annabel Chew,2 Reece C Hall,2 Cordelia ML Chan,2 Mohamad Rosman,1,2 Donald Tan,1–3 Louis Tong,1–4 Jodhbir S Mehta1–31Singapore Eye Research Institute, Singapore; 2Singapore National Eye Centre, Singapore; 3Department of Ophthalmology, Yong Loo Lin School of Medicine, National University of Singapore, Singapore; 4Duke-NUS Graduate Medical School, SingaporePurpose: To evaluate longitudinal changes in corneal sensitivity, tear function, and corneal staining in patients who underwent laser in situ keratomileusis (LASIK using two different femtosecond lasers.Methods: In a prospective, randomized clinical trial, contralateral eyes of 45 patients underwent flap creation by either VisuMax or IntraLase™ femtosecond laser. Corneal sensitivity, tear break up time (TBUT, Schirmer’s test, and corneal fluorescein staining were assessed preoperatively and at 1 week, 1 month, and 3 months postoperatively.Results: There were no statistical differences in any clinical outcome measure between the two femtosecond lasers (P > 0.05, although there was a trend towards slightly lower reductions for corneal sensitivity and TBUT in VisuMax-operated eyes. Overall, corneal sensitivity was significantly reduced at 1 week (P 0.05.Conclusion: This study showed that changes in corneal sensitivity, tear function, and corneal staining were statistically similar in LASIK using VisuMax and IntraLase femtosecond lasers for flap creation. However, the trend towards faster recovery of corneal sensitivity and TBUT observed in VisuMax-operated eyes may be attributable to improved technical specifications.Keywords: femtosecond laser, corneal sensitivity, tear film break-up time, Schirmer’s, corneal staining

  6. Open-Source Tools for Enhancing Full-Text Searching of OPACs: Use of Koha, Greenstone and Fedora

    Science.gov (United States)

    Anuradha, K. T.; Sivakaminathan, R.; Kumar, P. Arun

    2011-01-01

    Purpose: There are many library automation packages available as open-source software, comprising two modules: staff-client module and online public access catalogue (OPAC). Although the OPAC of these library automation packages provides advanced features of searching and retrieval of bibliographic records, none of them facilitate full-text…

  7. 40 CFR 62.15380 - How must I monitor opacity for air curtain incinerators that burn 100 percent yard waste?

    Science.gov (United States)

    2010-07-01

    ... waste? (a) Use EPA Reference Method 9 in Appendix A of 40 CFR part 60 to determine compliance with the opacity limit. (b) Conduct an initial test for opacity as specified in § 60.8 of subpart A of 40 CFR part... curtain incinerators that burn 100 percent yard waste? 62.15380 Section 62.15380 Protection of...

  8. 40 CFR 75.18 - Specific provisions for monitoring emissions from common and by-pass stacks for opacity.

    Science.gov (United States)

    2010-07-01

    ... emissions from common and by-pass stacks for opacity. 75.18 Section 75.18 Protection of Environment... Provisions § 75.18 Specific provisions for monitoring emissions from common and by-pass stacks for opacity. (a) Unit using common stack.When an affected unit utilizes a common stack with other affected...

  9. Outcome of corneal transplantation: can a prioritisation system predict outcome?

    OpenAIRE

    Saunders, Patrick P R; Sibley, Lyn M; Richards, John S F; Simon P. Holland; Chow, Debbie L; Courtright, Paul

    2002-01-01

    Background: In 1995 a prioritisation system for patients waiting for corneal transplantation surgery was adopted in British Columbia. In 1997 a routine outcome assessment programme was adopted. The authors sought to determine the outcomes of corneal transplant surgery in the province of British Columbia and to evaluate if they were associated with waiting list prioritisation.

  10. Genomics of corneal wound healing: a review of the literature.

    Science.gov (United States)

    Maycock, Nick J R; Marshall, John

    2014-05-01

    Corneal wound healing is a complex process: its mechanisms and the underlying genetic control are not fully understood. It involves the integrated actions of multiple growth factors, cytokines and proteases produced by epithelial cells, stromal keratocytes, inflammatory cells and lacrimal gland cells. Following an epithelial insult, multiple cytokines are released triggering a cascade of events that leads to repair the epithelial defect and remodelling of the stroma to minimize the loss of transparency and function. In this review, we examine the literature surrounding the genomics of corneal wound healing with respect to the following topics: epithelial and stromal wound healing (including inhibition); corneal neovascularisation; the role of corneal nerves in wound healing; the endothelium; the role of aquaporins and aptamers. We also examine the effect of ectasia on corneal wound healing with regard to keratoconus and following corneal surgery. A better understanding of the cellular and molecular changes that occur during repair of corneal wounds will provide the opportunity to design treatments that selectively modulate key phases of the healing process resulting in scars that more closely resemble normal corneal architecture.

  11. Applications and advantages of corneal crosslinking for treatment of keratoconus

    NARCIS (Netherlands)

    Soeters, N.

    2015-01-01

    Keratoconus is a corneal disorder in which the cornea becomes cone-shaped due to stromal thinning and corneal weakening. It mainly affects young individuals and although the prevalence is low (1:2000), the impact on quality of life is high. Despite much effort, still no cure has been found for

  12. Applications and advantages of corneal crosslinking for treatment of keratoconus

    NARCIS (Netherlands)

    Soeters, N.

    2015-01-01

    Keratoconus is a corneal disorder in which the cornea becomes cone-shaped due to stromal thinning and corneal weakening. It mainly affects young individuals and although the prevalence is low (1:2000), the impact on quality of life is high. Despite much effort, still no cure has been found for kerat

  13. Effects of genipin corneal crosslinking in rabbit corneas.

    Science.gov (United States)

    Avila, Marcel Y; Narvaez, Mauricio; Castañeda, Juan P

    2016-07-01

    To evaluate the effect of genipin, a natural crosslinking agent, in rabbit eyes. Department of Ophthalmology, Universidad Nacional de Colombia Centro de Tecnologia Oftalmica, Bogotá, Colombia. Experimental study. Ex vivo rabbit eyes (16; 8 rabbits) were treated with genipin 1.00%, 0.50%, and 0.25% for 5 minutes with a vacuum device to increase corneal permeability. Penetration was evaluated using Scheimpflug pachymetry (Pentacam). In the in vivo model (20 rabbits; 1 eye treated, 1 eye with vehicle), corneas were crosslinked with genipin as described. Corneal curvature, corneal pachymetry, and intraocular pressure (IOP) assessments as well as slitlamp examinations were performed 0, 7, 30, and 60 days after treatment. In the ex vivo model, Scheimpflug pachymetry showed deep penetration in the rabbit corneas with an increase in corneal density and a dose-dependent relationship. Corneal flattening was observed in treated eyes (mean 4.4 diopters ± 0.5 [SD]) compared with the control eyes. Pachymetry and IOP were stable in all evaluations. No eye showed toxicity in the anterior chamber or in the lens. Corneal crosslinking induced by genipin produced significant flattening of the cornea with no toxicity in rabbit eyes. This crosslinking could be useful in the treatment of corneal ectasia and in the modification of corneal curvature. None of the authors has a financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  14. Less Invasive Corneal Transepithelial Electrical Resistance Measurement Method.

    Science.gov (United States)

    Uematsu, Masafumi; Mohamed, Yasser Helmy; Onizuka, Naoko; Ueki, Ryotaro; Inoue, Daisuke; Fujikawa, Azusa; Sasaki, Hitoshi; Kitaoka, Takashi

    2016-01-01

    To evaluate acute corneal permeability changes after instillation of benzalkonium chloride (BAC) using a newly developed in vivo less invasive corneal transepithelial electrical resistance (TER) measurement method in animals and humans. We previously developed an in vivo method for measuring corneal TER using intraocular electrodes in animals. This method can be used to precisely measure the decline of the corneal barrier function after instillation of BAC. To lessen the invasiveness of that procedure, we further refined the method for measuring the corneal TER by developing electrodes that could be placed on the surface of the cornea and in the conjunctival sac instead of inserting them into the anterior chamber. Corneal TER changes before and after exposure to 0.02% BAC were determined in this study using the new device in both rabbits and humans. There was a significant decrease in the corneal TER after exposure of the cornea to 0.02% BAC solution in both rabbits and humans (Pmeasurement method enables us for the first time to measure TER of the human cornea, allowing safe and reliable investigation of the direct effect of different eye drop treatments on the corneal epithelium. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Corneal stem cells and tissue engineering: Current advancesand future perspectives

    Institute of Scientific and Technical Information of China (English)

    2015-01-01

    Major advances are currently being made in regenerativemedicine for cornea. Stem cell-based therapiesrepresent a novel strategy that may substituteconventional corneal transplantation, albeit there aremany challenges ahead given the singularities of eachcellular layer of the cornea. This review recapitulatesthe current data on corneal epithelial stem cells,corneal stromal stem cells and corneal endothelialcell progenitors. Corneal limbal autografts containingepithelial stem cells have been transplanted in humansfor more than 20 years with great successful rates,and researchers now focus on ex vivo cultures andother cell lineages to transplant to the ocular surface.A small population of cells in the corneal endotheliumwas recently reported to have self-renewal capacity,although they do not proliferate in vivo . Two mainobstacles have hindered endothelial cell transplantationto date culture protocols and cell delivery methods tothe posterior cornea in vivo . Human corneal stromalstem cells have been identified shortly after therecognition of precursors of endothelial cells. Stromalstem cells may have the potential to provide a directcell-based therapeutic approach when injected tocorneal scars. Furthermore, they exhibit the ability todeposit organized connective tissue in vitro and maybe useful in corneal stroma engineering in the future.Recent advances and future perspectives in the field arediscussed.

  16. In Vivo Corneal Biomechanical Properties with Corneal Visualization Scheimpflug Technology in Chinese Population

    Directory of Open Access Journals (Sweden)

    Ying Wu

    2016-01-01

    Full Text Available Purpose. To determine the repeatability of recalculated corneal visualization Scheimpflug technology (CorVis ST parameters and to study the variation of biomechanical properties and their association with demographic and ocular characteristics. Methods. A total of 783 healthy subjects were included in this study. Comprehensive ophthalmological examinations were conducted. The repeatability of the recalculated biomechanical parameters with 90 subjects was assessed by the coefficient of variation (CV and intraclass correlation coefficient (ICC. Univariate and multivariate linear regression models were used to identify demographic and ocular factors. Results. The repeatability of the central corneal thickness (CCT, deformation amplitude (DA, and first/second applanation time (A1/A2-time exhibited excellent repeatability (CV% ≤ 3.312% and ICC ≥ 0.929 for all measurements. The velocity in/out (Vin/out, highest concavity- (HC- radius, peak distance (PD, and DA showed a normal distribution. Univariate linear regression showed a statistically significant correlation between Vin, Vout, DA, PD, and HC-radius and IOP, CCT, and corneal volume, respectively. Multivariate analysis showed that IOP and CCT were negatively correlated with Vin, DA, and PD, while there was a positive correlation between Vout and HC-radius. Conclusion. The ICCs of the recalculated parameters, CCT, DA, A1-time, and A2-time, exhibited excellent repeatability. IOP, CCT, and corneal volume significantly influenced the biomechanical properties of the eye.

  17. Customized toric intraocular lens implantation for correction of extreme corneal astigmatism due to corneal scarring

    Directory of Open Access Journals (Sweden)

    R Bassily

    2010-03-01

    Full Text Available R Bassily, J LuckOphthalmology Department, Royal United Hospital, Combe Park, Bath, UKAbstract: A 76-year-old woman presented with decreased visual function due to cataract formation. Twenty-five years prior she developed right sided corneal ulceration that left her with 10.8 diopters (D of irregular astigmatism at 71.8° (steep axis. Her uncorrected visual acuity was 6/24 and could only ever wear a balanced lens due to the high cylindrical error. Cataract surgery was planned with a custom designed toric intraocular lens (IOL with +16.0 D sphere inserted via a wound at the steep axis of corneal astigmatism. Postoperative refraction was -0.75/+1.50 × 177° with a visual acuity of 6/9 that has remained unchanged at six-week follow-up with no IOL rotation. This case demonstrates the value of high power toric IOLs for the correction of pathological corneal astigmatism.Keywords: intraocular lens, corneal ulceration, visual acuity, scarring

  18. Gaseous Mean Opacities for Giant Planet and Ultracool Dwarf Atmospheres over a Range of Metallicities and Temperatures

    CERN Document Server

    Freedman, Richard S; Fortney, Jonathan J; Lupu, Roxana E; Marley, Mark S; Lodders, Katharina

    2014-01-01

    We present new calculations of Rosseland and Planck gaseous mean opacities relevant to the atmospheres of giant planets and ultracool dwarfs. Such calculations are used in modeling the atmospheres, interiors, formation, and evolution of these objects. Our calculations are an expansion of those presented in Freedman et al. (2008) to include lower pressures, finer temperature resolution, and also the higher metallicities most relevant for giant planet atmospheres. Calculations span 1 microbar to 300 bar, and 75 K to 4000 K, in a nearly square grid. Opacities at metallicities from solar to 50 times solar abundances are calculated. We also provide an analytic fit to the Rosseland mean opacities over the grid in pressure, temperature, and metallicity. In addition to computing mean opacities at these local temperatures, we also calculate them with weighting functions up to 7000 K, to simulate the mean opacities for incident stellar intensities, rather than locally thermally emitted intensities. The chemical equilib...

  19. Comment on "Large enhancement in high-energy photoionization of Fe XVII and missing continuum plasma opacity"

    CERN Document Server

    Blancard, C; Cossé, Ph; Faussurier, G; Fontes, C J; Gilleron, F; Golovkin, I; Hansen, S B; Iglesias, C A; Kilcrease, D P; MacFarlane, J J; More, R M; Pain, J -C; Sherrill, M; Wilson, B G

    2016-01-01

    Recent R-matrix calculations claim to produce a significant enhancement in the opacity of Fe XVII due to atomic core excitations [S. N. Nahar & A.K. Pradhan, Phys. Rev. Letters 116, 235003 (2016), arXiv:1606.02731] and assert that this enhancement is consistent with recent measurements of higher-than-predicted iron opacities [J. E. Bailey et al., Nature 517, 56 (2015)]. This comment shows that the standard opacity models which have already been directly compared with experimental data produce photon absorption cross-sections for Fe XVII that are effectively equivalent to (and in fact larger than) the new R-matrix opacities. Thus, the new R-matrix results cannot be expected to significantly impact the existing discrepancies between theory and experiment because they produce neither a "large enhancement" nor account for "missing continuum plasma opacity" relative to standard models.

  20. Evidence-based Homoeopathy: A case of corneal abscess

    Directory of Open Access Journals (Sweden)

    Sandeep Sudhakar Sathye

    2016-01-01

    Full Text Available Corneal abscess is a circumscribed collection of pus within the layers of cornea. It is usually endogenous in origin and commonly found near the limbal blood vessels close to corneal margin. Treatment in modern medicine is use of local and systemic antibiotics. Homoeopathy has mentioned medicines for corneal abscess. A case reported was a female of 68 years of age suffering from symptoms of redness, dull pain, and foreign body sensation in the right eye and was diagnosed as corneal abscess. The homoeopathic medicine Hepar sulphuris 200C was prescribed on the basis of pathology. Abscess was reduced considerably within 5 days and it was absorbed completely in 21 days. No recurrence of abscess was observed thereafter. Ocular photographs during follow-up visits have provided documentary evidence about the effectiveness of homoeopathic Hepar sulphuris 200C in corneal abscess.

  1. Paracentral Corneal Dellen:A Rare Sign of Graves Ophthalmopathy

    Institute of Scientific and Technical Information of China (English)

    Jianhua Yan; Zhongyao Wu

    2003-01-01

    Purpose: To report a rare sign, paracentral corneal dellen that developed in a middleaged female patient with Graves ophthalmopathy.Methods:A paracentral corneal dellen developed in the left eye in a 42-year-old woman who was diagnosed as Graves ophthalmopathy. The patient had remarkable upper eyelid retraction, upper eyelid lag and upward motility restriction. The Graves ophthalmopathy was classified as Grade V according to NOSPECS classification.Results:Local artificial tear film and 0.3% Tobramycin eye drops were administered to both eyes.Twenty-four hours later, the left corneal dellen disappeared.Conclusions:Graves ophthalmopathy can lead to paracentral corneal dellen because of severe upper eyelid retraction and upward motility restriction of the eye in spite of the lack of lagophthalmos. Artificial tear drop and antibiotic eye drop therapy helped even though the patient did not have corneal exposure.

  2. Mechanism of Corneal Endothelial Cells Lesion during Phacoemulsification and Aspiration

    Institute of Scientific and Technical Information of China (English)

    Songtao Yuan; Lina Xie; Qinghuai Liu; Nanrong Yuan

    2003-01-01

    Purpose: To evaluate the proportions of corneal endothelial lesion caused by differentfactors during phacoemulsification and aspiration.Methods: Fourteen cats (twenty eight eyes) were divided into four groups. The processedfactors were ultrasonic power, lens extraction by phacoemulsification or not, and lensextraction using different levels of ultrasonic power. The density of central cornealendothelial cells was measured before and after operation.Results: There is no statistic difference between pre-operation density and post-operationdensity for releasing ultrasonic power only without lens extraction group. But for the lensextraction group, there is difference in density of central corneal endothelial cells andthe higher level of ultrasonic power, the more the central corneal endothelial cells densitydecreased through operation.Conclusion: The primary factor that causes corneal endothelial lesion duringphacoemulsification and aspiration procedure is debris of lens nucleus, and the otherfactors cause the lesion of corneal endothelium in normal operations just in very smalldegree.

  3. Biomechanical and morphological corneal response to placement of intrastromal corneal ring segments for keratoconus.

    Science.gov (United States)

    Dauwe, Caroline; Touboul, David; Roberts, Cynthia J; Mahmoud, Ashraf M; Kérautret, Julien; Fournier, Pierre; Malecaze, François; Colin, Joseph

    2009-10-01

    To evaluate the biomechanical and morphological changes in keratoconic corneas after Intacs intrastromal corneal ring segment (ICRS) implantation. Department of Ophthalmology, National Reference Center for Keratoconus, Bordeaux University, Bordeaux, France. Keratoconic eyes were retrospectively analyzed after ICRS implantation; preoperative and 6-month postoperative evaluation were done using the Ocular Response Analyzer (ORA) and the Orbscan II topographer. Biomechanical parameters included corneal hysteresis (CH), the corneal resistance factor (CRF), and other parameters extracted from the signal curves. Morphological parameters included simulated keratometry and the cone location magnitude index from the axial map (aCLMI) and tangential map (tCLMI). Parameters were extracted using software designed to read and process topographic maps. There were no significant differences between preoperatively and postoperatively in mean CH (7.7 mm Hg +/- 1.4 [SD] versus 7.4 +/- 1.4 mm Hg) or mean CRF (6.6 +/- 1.8 mm Hg versus 6.1 +/- 1.4 mm Hg). Only 2 ORA signal parameters were significantly different. Topographic parameters with significant decreases were minimum central keratometry (K) (mean change -5.8 +/- 2.9 diopters [D]) (P<.001), minimum central K (mean change -5.8 +/- 2.3 D) (P<.001), mean aCLMI (9.6 +/- 2.7 preoperatively versus 7.7 +/- 2.5 postoperatively) (P<.009), and mean tCLMI (18.9 +/- 2.8 versus 12.9 +/- 4.4) (P<.002). The only significant correlation between biomechanical and topographic parameters was postoperative ORA infrared signal peak 1 and postoperative aCLMI. Intrastromal corneal ring implantation significantly decreased corneal curvature, with preoperative values predicting magnitude of change. However, it did not alter the viscoelastic biomechanical parameters of CH and CRF.

  4. Corneal confocal microscopy is a rapid reproducible ophthalmic technique for quantifying corneal nerve abnormalities.

    Science.gov (United States)

    Kalteniece, Alise; Ferdousi, Maryam; Adam, Safwaan; Schofield, Jonathan; Azmi, Shazli; Petropoulos, Ioannis; Soran, Handrean; Malik, Rayaz A

    2017-01-01

    To assess the effect of applying a protocol for image selection and the number of images required for adequate quantification of corneal nerve pathology using in vivo corneal confocal microscopy (IVCCM). IVCCM was performed in 35 participants by a single examiner. For each participant, 4 observers used a standardized protocol to select 6 central corneal nerve images to assess the inter-observer variability. Furthermore, images were selected by a single observer on two occasions to assess intra-observer variability and the effect of sample size was assessed by comparing 6 with 12 images. Corneal nerve fiber density (CNFD), branch density (CNBD) and length (CNFL) were quantified using fully automated software. The data were compared using the intra class correlation coefficient (ICC) and Bland-Altman agreement plots for all experiments. The ICC values for CNFD, CNBD and CNFL were 0.93 (P<0.0001), 0.96 (P<0.0001) and 0.95 (P<0.0001) for inter-observer variability and 0.95 (P<0.0001), 0.97 (P<0.001) and 0.97 (P<0.0001) for intra-observer variability. For sample size variability, ICC values were 0.94 (P<0.0001), 0.95 (P<0.0001), and 0.96 (P<0.0001) for CNFD, CNBD and CNFL. Bland-Altman plots showed excellent agreement for all parameters. This study shows that implementing a standardized protocol to select IVCCM images results in high intra and inter-observer reproducibility for all corneal nerve parameters and 6 images are adequate for analysis. IVCCM could therefore be deployed in large multicenter clinical trials with confidence.

  5. Intrastromal corneal ring segments delay corneal grafting in patients with keratoconus

    Directory of Open Access Journals (Sweden)

    Luiz Arthur F. Beniz

    2016-02-01

    Full Text Available ABSTRACT Purpose: To assess the impact of intrastromal corneal ring segments (ICRS as a surgical alternative to corneal grafting in patients with keratoconus who were scheduled for a corneal transplant. Methods: This single-surgeon, single-center, retrospective, observational case series study included 19 eyes of 18 patients (mean age, 23.36 ± 6.22 years with a confirmed diagnosis of keratoconus. These patients were enrolled from the State of Goiás, Brazil corneal graft waiting list. Following extensive pre-operative testing, including the measurement of best-corrected visual acuity (BCVA, applanation tonometry, biomicroscopy, funduscopy, pachymetry, and corneal topography, patients were implanted with Keraring® ICRS. Patients underwent clinical examination at postoperative days 1, 7, 30, 90, and 180 and were examined again 2 years following surgery. Results: At the 2-year cut-off following ICRS implantation (mean follow-up, 28.72 ± 4.71 months, there was a statistically significant improvement in BCVA (logMAR from 0.59 ± 0.35 preoperatively to 0.35 ± 0.45 postoperatively ( p <0.01. Three of 19 eyes (15.8% still required keratoplasty. In the remaining patients (84.2%, BCVA was managed with spectacles (52.6% or contact lenses (31.6%. One patient developed infectious keratitis, requiring removal of ICR at the first postoperative visit. Conclusion: ICRS implantation may be a surgical alternative to keratoplasty in patients with keratoconus. This procedure may delay or even eliminate the need for keratoplasty in such patients.

  6. 77 FR 8209 - Quality Assurance Requirements for Continuous Opacity Monitoring Systems at Stationary Sources

    Science.gov (United States)

    2012-02-14

    ... AGENCY 40 CFR Part 60 RIN 2060-AH23 Quality Assurance Requirements for Continuous Opacity Monitoring... standards as specified in federally enforceable regulations. The quality assurance requirements will be... standards to the quality assurance requirements in Appendix F of 40 CFR Part 60 in the ``Rules and...

  7. Impact of Internet Search Engines on OPAC Users: A Study of Punjabi University, Patiala (India)

    Science.gov (United States)

    Kumar, Shiv

    2012-01-01

    Purpose: The aim of this paper is to study the impact of internet search engine usage with special reference to OPAC searches in the Punjabi University Library, Patiala, Punjab (India). Design/methodology/approach: The primary data were collected from 352 users comprising faculty, research scholars and postgraduate students of the university. A…

  8. Effect of Media Opacity on Retinal Nerve Fiber Layer Thickness Measurements by Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Dae Woong Lee

    2010-01-01

    Full Text Available Purpose: To assess the effect of ocular media opacity on retinal nerve fiber layer (RNFL thickness measurements by optical coherence tomography (OCT. Methods: In this prospective, non-randomized clinical study, ocular examinations and OCT measurements were performed on 77 cataract patients, 80 laser refractive surgery patients and 90 patients whose signal strength on OCT was different on two consecutive measurements. None of the eyes had preexisting retinal or optic nerve pathology, including glaucoma. Cataracts were classified according to the Lens Opacity Classification System III (LOCS III. All eyes were scanned with the Stratus OCT using the Fast RNFL program before and three months after surgery. Internal fixation was used during scanning and all eyes underwent circular scans around the optic disc with a diameter of 3.4 mm. Results: Average RNFL thickness, quadrant thickness and signal strength significantly increased after cataract surgery (P<0.05. Cortical and posterior subcapsular cataracts, but not nuclear cataracts, had a significant influence on RNFL thickness measurements (P<0.05. There was no significant difference between OCT parameters before and after laser refractive surgery. In eyes for which different signal strengths were observed, significantly larger RNFL thickness values were obtained on scans with higher signal strengths. Conclusion: OCT parameters are affected by ocular media opacity because of changes in signal strength; cortical cataracts have the most significant effect followed by posterior subcapsular opacities. Laser refractive procedures do not seem to affect OCT parameters significantly.

  9. Gluon Radiation off Hard Quarks in a Nuclear Environment Opacity Expansion

    CERN Document Server

    Wiedemann, Urs Achim

    2000-01-01

    We study the relation between the Baier-Dokshitzer-Mueller-Peigne-Schiff (BDMPS) and Zakharov formalisms for medium-induced gluon radiation off hard quarks, and the radiation off very few scattering centers. Based on the non-abelian Furry approximation for the motion of hard partons in a spatially extended colour field, we derive a compact diagrammatic and explicitly colour trivial expression for the N-th order term of the kt-differential gluon radiation cross section in an expansion in the opacity of the medium. Resumming this quantity to all orders in opacity, we obtain Zakharov's path-integral expression (supplemented with a regularization prescription). This provides a new proof of the equivalence of the BDMPS and Zakharov formalisms which extends previous arguments to the kt-differential cross section. We give explicit analytical results up to third order in opacity for both the gluon radiation cross section of free incoming and of in-medium produced quarks. The N-th order term in the opacity expansion o...

  10. Important consequences of atomic diffusion inside main-sequence stars: opacities, extra-mixing, oscillations

    Directory of Open Access Journals (Sweden)

    Deal M.

    2017-01-01

    Full Text Available Atomic diffusion, including the effects of radiative accelerations on individual elements, leads to important variations of the chemical composition inside stars. The accumulation of important elements in specific layers leads to a local increase of the average opacity and to hydrodynamic instabilities that modify the internal stellar structure. This can also have important consequences for asteroseismology.

  11. Opportunities for Laboratory Opacity Chemistry Studies to Facilitate Characterization of Young Giant Planets and Brown Dwarfs

    Science.gov (United States)

    Marley, Mark; Freedman, Richard S.

    2015-01-01

    The thermal emission spectra of young giant planets is shaped by the opacity of atoms and molecules residing in their atmospheres. While great strides have been made in improving the opacities of important molecules, particularly NH3 and CH4, at high temperatures, much more work is needed to understand the opacity and chemistry of atomic Na and K. The highly pressure broadened fundamental band of Na and K in the optical stretches into the near-infrared, strongly influencing the shape of the Y and K spectral bands. Since young giant planets are bright in these bands it is important to understand the influences on the spectral shape. Discerning gravity and atmospheric composition is difficult, if not impossible, without both good atomic opacities as well as an excellent understanding of the relevant atmospheric chemistry. Since Na and K condense at temperatures near 500 to 600 K, the chemistry of the condensation process must be well understood as well, particularly any disequilibrium chemical pathways. Comparisons of the current generation of sophisticated atmospheric models and available data, however, reveal important shortcomings in the models. We will review the current state of observations and theory of young giant planets and will discuss these and other specific examples where improved laboratory measurements for alkali compounds have the potential of substantially improving our understanding of these atmospheres.

  12. Influence of the atmospheric opacity cycle on the near surface environment of Gale Crater on Mars

    Science.gov (United States)

    de la Torre Juarez, Manuel; Gomez-Elvira, Javier; Guzewich, Scott David; Lemmon, Mark T.; Martinez, German; Mason, Emily; Navarro, Sara; Newman, Claire E.; Smith, Michael D.; Retortillo, Alvaro de Vicente

    2016-10-01

    The Mars atmospheric dust changes the capacity of the atmosphere to absorb solar radiation or release outgoing thermal infrared radiation. This alters the atmospheric heat exchange fluxes and can interfere with the global circulation. The response of near surface pressure, temperature and winds has been characterized at the higher northern latitudes of 45 degree N at the Viking landing sites. The Rover Environmental Monitoring Station (REMS) on Curiosity allows a similar characterization at near-equatorial latitudes of 4.5 degree S. Using MCAM-880 nm opacities as a measure of local atmospheric dust load, we analyze the response of changes in surface variables measured by REMS and compare to those observed by Viking. As on Viking, diurnal and semidiurnal pressure tide amplitudes track very closely the atmospheric opacity and the mean daily pressure shows the increased wave activity. Temperature tides show a more complex response that combines its sensitivity to changes in dust and cloud opacities. Differences in UV opacities for the REMS set of finite spectral windows are explored during the dust and clear seasons.

  13. Asymptotic Giant Branch stars at low metallicity: the challenging interplay between mass loss and molecular opacities

    CERN Document Server

    Ventura, Paolo

    2010-01-01

    We investigate the main physical properties of low-metallicity Asymptotic Giant Branch stars, with the aim of quantifying the uncertainties that presently affect the predicted chemical yields of these stars, associated to mass loss and description of molecular opacities. We find that above a threshold mass, M ~ 3.5Msun for Z=0.001, the results are little dependent on the opacity treatment, as long as hot-bottom burning prevents the surface C/O ratio from exceeding unity; the yields of these massive AGB stars are expected to be mostly determined by the efficiency of convection, with a relatively mild dependence on the mass-loss description. A much higher degree of uncertainty is associated to the yields of less massive models, which critically depend on the adopted molecular opacities. An interval of masses exists, say 2.0-3.0Msun, (the exact range depends on mass loss), in which HBB may be even extinguished following the cooling produced by the opacity of C-bearing molecules. The yields of these stars are the...

  14. [Corneal permeability of topically applied pirenzepine solution].

    Science.gov (United States)

    Wang, Kai-di; Zhang, Jin-song; Yan, Pan-shi

    2006-06-01

    To study the corneal permeability of three different pirenzepine eye-drop solutions and provide reference for further clinical use. Sixty-three New Zealand white rabbits were divided into three groups. Each group of rabbits received 2% pirenzepine (pirenzepine group), 2% pirenzepine with 0.1% hyaluronic acid (hyaluronic acid group), or 2% pirenzepine with 0.1% azone (azone group). One drop eye-drops was applied to conjunctive sac every 5 min for six times. Aqueous samples were obtained from each group at 0.5, 1.0, 2.0, 4.0, 8.0, 12.0, 24.0 h after the last drop, respectively. Concentration of pirenzepine in these samples was determined by the HPLC (high pressure liquid chromatography). Stimulation symptom of rabbit eyes was also observed. The concentrations of pirenzepine in aqueous humor were (0.40 +/- 0.06) microg/ml at 0.5 h, (0.53 +/- 0.03) microg/ml at 1.0 h, (1.52 +/- 0.33) microg/ml at 2.0 h and (0.15 +/- 0.02) microg/ml at 4.0 h in pirenzepine group. Aqueous humor concentration of pirenzepine in both 2% pirenzepine with 0.1% azone and 2% pirenzepine with 0.1% hyaluronic acid were significantly higher than that of single pirenzepine application, and their bioavailability in the groups with combinations of pirenzepine with 0.1% azone or 0.1% hyaluronic acid were 23.0 times and 3.4 times higher than that of single pirenzepine usage. No obvious irritate symptom was found in rabbit of all three groups after eye-drop applying. The combination application of pirenzepine with azone or hyaluronic acid has higher corneal permeability compared with pirenzepine alone. This result indicates that azone and hyaluronic acid could be used in pirenzepine eye-drop solution to increase corneal permeability.

  15. Automated Decision Tree Classification of Corneal Shape

    Science.gov (United States)

    Twa, Michael D.; Parthasarathy, Srinivasan; Roberts, Cynthia; Mahmoud, Ashraf M.; Raasch, Thomas W.; Bullimore, Mark A.

    2011-01-01

    Purpose The volume and complexity of data produced during videokeratography examinations present a challenge of interpretation. As a consequence, results are often analyzed qualitatively by subjective pattern recognition or reduced to comparisons of summary indices. We describe the application of decision tree induction, an automated machine learning classification method, to discriminate between normal and keratoconic corneal shapes in an objective and quantitative way. We then compared this method with other known classification methods. Methods The corneal surface was modeled with a seventh-order Zernike polynomial for 132 normal eyes of 92 subjects and 112 eyes of 71 subjects diagnosed with keratoconus. A decision tree classifier was induced using the C4.5 algorithm, and its classification performance was compared with the modified Rabinowitz–McDonnell index, Schwiegerling’s Z3 index (Z3), Keratoconus Prediction Index (KPI), KISA%, and Cone Location and Magnitude Index using recommended classification thresholds for each method. We also evaluated the area under the receiver operator characteristic (ROC) curve for each classification method. Results Our decision tree classifier performed equal to or better than the other classifiers tested: accuracy was 92% and the area under the ROC curve was 0.97. Our decision tree classifier reduced the information needed to distinguish between normal and keratoconus eyes using four of 36 Zernike polynomial coefficients. The four surface features selected as classification attributes by the decision tree method were inferior elevation, greater sagittal depth, oblique toricity, and trefoil. Conclusions Automated decision tree classification of corneal shape through Zernike polynomials is an accurate quantitative method of classification that is interpretable and can be generated from any instrument platform capable of raw elevation data output. This method of pattern classification is extendable to other classification

  16. Mycotic corneal ulcers in upper Assam

    Directory of Open Access Journals (Sweden)

    Reema Nath

    2011-01-01

    Full Text Available Purpose : To study the association of various risk factors and epidemiological variables of mycotic keratitis treated at a tertiary referral hospital of upper Assam. Materials and Methods: In this hospital-based prospective study a total of 310 consecutive corneal ulcer cases attending the ophthalmology outpatient department of Assam Medical College were enrolled between April 2007 and March 2009. After clinical and slit-lamp biomicroscopic examination in all suspected cases, smears and culture examination for fungus was done to establish the etiology. Demographic information and associated probable risk factors of individual cases were noted in a predesigned questionnaire. Results: In 188 (60.6% cases fungal etiology could be established. Out of them 67.6% were males. The most commonly affected age group was 41-50 years (25.5%. The maximum (23.4% cases were reported during the paddy harvesting season in Assam (January and February. Fungal element could be demonstrated in 65.2% cases in direct potassium hydroxide (KOH mount. The commonest predisposing factor was corneal injury (74.5%. While diabetes was a significant systemic predisposing factor in mixed bacterial and fungal infections in 11.1% cases, blocked naso-lacrimal duct was the local predisposing factor in 11.1% of cases. Fusarium solani (25% was the commonest isolate followed by Aspergillus species (19%, Curvularia species (18.5% and Penicillium species (15.2%. Yeasts were isolated in 2.7% (n=5 cases. Conclusions : Ocular trauma was the commonest cause of fungal corneal ulcer in Assam and Fusarium solani was the commonest species responsible for it. Most of the mycotic ulcer cases come from rural areas including the tea gardens.

  17. Fractal dimension based corneal fungal infection diagnosis

    Science.gov (United States)

    Balasubramanian, Madhusudhanan; Perkins, A. Louise; Beuerman, Roger W.; Iyengar, S. Sitharama

    2006-08-01

    We present a fractal measure based pattern classification algorithm for automatic feature extraction and identification of fungus associated with an infection of the cornea of the eye. A white-light confocal microscope image of suspected fungus exhibited locally linear and branching structures. The pixel intensity variation across the width of a fungal element was gaussian. Linear features were extracted using a set of 2D directional matched gaussian-filters. Portions of fungus profiles that were not in the same focal plane appeared relatively blurred. We use gaussian filters of standard deviation slightly larger than the width of a fungus to reduce discontinuities. Cell nuclei of cornea and nerves also exhibited locally linear structure. Cell nuclei were excluded by their relatively shorter lengths. Nerves in the cornea exhibited less branching compared with the fungus. Fractal dimensions of the locally linear features were computed using a box-counting method. A set of corneal images with fungal infection was used to generate class-conditional fractal measure distributions of fungus and nerves. The a priori class-conditional densities were built using an adaptive-mixtures method to reflect the true nature of the feature distributions and improve the classification accuracy. A maximum-likelihood classifier was used to classify the linear features extracted from test corneal images as 'normal' or 'with fungal infiltrates', using the a priori fractal measure distributions. We demonstrate the algorithm on the corneal images with culture-positive fungal infiltrates. The algorithm is fully automatic and will help diagnose fungal keratitis by generating a diagnostic mask of locations of the fungal infiltrates.

  18. Production of Hypoxia-induced Corneal Edema in Aged Eyes

    Institute of Scientific and Technical Information of China (English)

    Alan K. Cheung; Andrew W. Siu; Digby W. Cheung; Edwin C. Mo

    2004-01-01

    Purpose:Corneal thickness assessment is a common clinical procedure applied in corneal and contact lens care. This study aims to investigate the effect of age on hypoxiainduced corneal swelling.Methods:Eighteen male subjects were equally divided into the younger [(23.7±0.8) and older [(74.4±2.5) years old]groups.Each subject wore a thick soft contact lens (uniform thickness of 0.3 mm) on the left cornea. With the contact lens in place, the baseline central corneal thickness was measured using a specially designed photo-pachometer. The lens was then patched behind the closed eyelids, producing an extremely hypoxic stress to the cornea. The change in central corneal thickness was monitored every 20 minutes with momentary disruptions to the hypoxic stress over the next 2 hours. The increase in thickness was taken as an index of corneal edema. The rate of change in corneal thickness, as derived from a non-linear mathematical model, was compared between groups. Results:The corneal thickness of both age groups increased significantly with time (P<0.000 1 ). The mean corneal swelling constant for the older subjects was 16.5 × 10-3 (S.E.M. = 2.65 × 10-3) and the value for the younger subjects was 46.5 × 10-3 (S.E.M. = 3.25× 10-3). The difference was statistically significant (P < 0.000 1 ).Conclusion:Aging cornea has a slower hypoxia-induced edema response compared with the younger group. Whether it is caused by a decreased corneal lactate production or an increased resistance to physical expansion deserves further investigation. Eye Science2004;20:1-5.

  19. Riboflavin concentration in corneal stroma after intracameral injection

    Institute of Scientific and Technical Information of China (English)

    Na; Li; Xiu-Jun; Peng; Zheng-Jun; Fan; Xu; Pang; Yu; Xia; Teng-Fei; Wu

    2015-01-01

    AIM: To evaluate the enrichment of riboflavin in the corneal stroma after intracameral injection to research the barrier ability of the corneal endothelium to riboflavin in vivo.METHODS: The right eyes of 30 New Zealand white rabbits were divided into three groups. Different concentrations riboflavin-balanced salt solutions(BSS)were injected into the anterior chamber(10 with 0.5%, 10 with 1%, and 10 with 2%). Eight corneal buttons of 8.5mm in diameter from each group were dissected at 30 min after injection and the riboflavin concentrations in the corneal stroma were determined using high-performance liquid chromatography(HPLC) after removing the epithelium and endothelium. The other two rabbits in every group were observed for 24 h and sacrificed. As a comparison, the riboflavin concentrations from 16 corneal stromal samples were determined using HPLC after instillation of 0.1% riboflavin-BSS solution for30 min on the corneal surface(8 without epithelium and 8with intact epithelium).RESULTS: The mean riboflavin concentrations were11.19, 18.97, 25.08, 20.18, and 1.13 μg/g for 0.5%, 1%, 2%,de-epithelialzed samples, and the transepithelial groups,respectively. The color change of the corneal stroma and the HPLC results showed that enrichment with riboflavin similar to classical de-epithelialized corneal collagen crosslinking(CXL) could be achieved by intracameral 1%riboflavin-BSS solution after 30min; the effect appeared to be continuous for at least 30 min.CONCLUSION: Riboflavin can effectively penetrate the corneal stroma through the endothelium after an intracameral injection in vivo, so it could be an enhancing method that could improve the corneal riboflavin concentration in transepithelial CXL.

  20. A Novel Technique to Calculate UV Opacity at Gale Crater from MSL/REMS Measurements

    Science.gov (United States)

    Vicente-Retortillo, Álvaro; Martínez, Germán M.; Renno, Nilton O.; Lemmon, Mark T.; Mason, Emily L.; de la Torre-Juárez, Manuel

    2016-04-01

    The Rover Environmental Monitoring Station (REMS) on board the Mars Science Laboratory (MSL) mission carries a UV sensor that for the first time is measuring the solar radiation at the surface of Mars in six bands between 200 and 380 nm [1]. Here we present a novel methodology to calculate the atmospheric opacity by using the UV photodiode output currents measured by this sensor (TELRDR products) and ancillary (ADR) data. We estimate the diffuse and total radiation signals by analyzing the events in which the direct solar beam was temporarily blocked by the masthead or by the mast of the rover. Then we use a radiative transfer model with updated radiative properties of the Martian aerosols ([2], [3]) based on the Monte-Carlo method to retrieve the UV opacity from those measurements. Therefore, this methodology is not sensitive to the degradation of the sensor due to the deposition of dust on it. In addition, by using TELRDR and ADR data, inconsistencies in the processed reduced data (ENVRDR and MODRDR products, in units of W/m2) found when the solar zenith angle relative to REMS rover frame is above 30° are avoided. In order to validate our technique, we compare the UV opacities with those derived from Mastcam observations at 880 nm. We find that both opacities show a good agreement and follow a similar seasonal trend, with the UV opacity showing values generally lower than at 880 nm. The difference between both opacities varies over the year, with the minimum difference occurring during the first half of the winter, when both opacities show their annual lowest values. The temporal variation of this difference may be used to analyze changes in the dust size distribution. [1] Gómez-Elvira, J., Armiens, C., Castañer, L., Domínguez, M., Genzer, M. et al. REMS: the environmental sensor suite for the Mars Science Laboratory rover. Space Sci. Rev., 170 (1-4), 583-640, 2012. [2] Vicente-Retortillo, A., Valero, F., Vázquez, L. and Martínez, G. M. A model to calculate

  1. Corneal surface reconstruction - a short review

    Directory of Open Access Journals (Sweden)

    Madhavan H N

    2009-01-01

    Full Text Available Cornea is the clear, dome-shaped surface that covers the front of the eye and when damage due to burns or injury and several other diseases, stem cells residing in its rim called "limbus" are stimulated to multiply to support growth of new epithelial cells over its surface. If this ready source of stem cells is damaged or destroyed the natural repair is not possible and such a condition is known as corneal limbal stem cell deficiency (CLSCD disease. Stem cell transplant helps such persons to regenerate the corneal surface. Human corneal limbal stem cell transplantation is at present an established procedure with reasonable good clinical outcome particularly when autologous limbal epithelial tissue from a fellow unaffected eye is used. 1, 2 A major concern related to the autograft is the possibility of CLSCD at the donor site, 3 techniques that allowed the expansion of a small limbal biopsy in the laboratory using cell cultures that could be then transplanted to the affected eye have been developed ,4, 5 Human amniotic membrane (HAM is used as a scaffold for both culturing the human limbal epithelial cells and for ocular surface reconstruction with the cultured limbal epithelial cells. 4-7 However, researchers have used alternative scaffolds like collagen 8, fibrin gel 9 and cross-linked gel of fibronectin and fibrin. 10 All these are biological materials and also need for animal 3T3 feeder layer for stem cell cultures. The properties of HAM are unique including antiadhesive effects, bacteriostatic effects, wound protection, pain reduction, and improvement of epithelialization and characteristically lacking imunogenicity. The use of amniotic membrane transplantation (AMT to treat ocular surface abnormalities was first reported by Graziella Pellegrini, chief of stem cell laboratory at Giovanni Paolo Hospital in Venice, Italy, who was the first to demonstrate the limbal stem cell transplant in 1997. Amniotic membrane has been successfully used in

  2. Graft Biomechanics Following Three Corneal Transplantation Techniques

    Science.gov (United States)

    Feizi, Sepehr; Montahai, Talieh; Moein, Hamidreza

    2015-01-01

    Purpose: To compare corneal biomechanical properties following three different transplantation techniques, including Descemet stripping automated endothelial keratoplasty (DSAEK), deep anterior lamellar keratoplasty (DALK) and penetrating keratoplasty (PK) in comparison to normal eyes. Methods: This cross-sectional comparative study included 118 eyes: 17 eyes of 17 patients received DSAEK, 23 eyes of 21 patients underwent DALK using Anwar's big bubble technique, and 45 eyes of 36 patients had PK; 33 right eyes of 33 normal subjects served as the control group. Using the ocular response analyzer (ORA, Reichert Ophthalmic Instruments, Buffalo, New York, USA), corneal hysteresis (CH) and corneal resistance factor (CRF) were measured and compared among the study groups at least 3 months after all sutures were removed. Results: Mean patient age was 26.9 ± 5.0 years in the control group, 28.8 ± 4.2 in the PK group, 27.2 ± 6.5 in the DALK group, and 62.5 ± 16.8 in the DSAEK group (P < 0.001). Central corneal thickness (CCT) was 539.0 ± 24.8, 567.5 ± 38.8, 547.0 ± 42.6 and 631.1 ± 84.8 μm, respectively (P < 0.001). CH and CRF were significantly lower in the DSAEK group (7.79 ± 2.0 and 7.88 ± 1.74 mmHg, respectively) as compared to the PK (10.23 ± 2.07 and 10.13 ± 2.22 mmHg, respectively) and DALK (9.64 ± 2.07 and 9.36 ± 2.09 mmHg, respectively) groups. The two latter groups demonstrated biomechanical parameters comparable to normal subjects (9.84 ± 1.59 and 9.89 ± 1.73 mmHg, respectively). Conclusion: Graft biomechanical parameters after DSAEK are lower than those following PK and DALK. After PK and DALK in keratoconic eyes, these metrics are increased to normal values. These differences may have implications for interpreting intraocular pressure or planning graft refractive surgery after keratoplasty. PMID:26730307

  3. 人角膜内皮细胞增殖特性及能力的研究进展%Research progress on proliferative property and capacity of human corneal endothelium

    Institute of Scientific and Technical Information of China (English)

    潘飞; 姚玉峰

    2011-01-01

    Primary and secondary corneal endothelial decompensation leads to stromal edema,corneal opacity and loss of visual acuity. The pathogenesis of corneal endothelial decompensation is that adult corneal endothelium in vivo lacks of a robust proliferative response to injury, does not divide sufficiently to replace the lost cells. Previous studies indicate that cell-cell contact inhibition and transforming growth factor-beta2 (TGF-β2) in aqueous humor may be responsible for maintaining human endothelial cells in a non-replicative state in vivo. The results of the experimental investigation by using immunofluorescent staining of the cell cycle-associated proteins and cell proliferation marker Ki67 in corneal endothelium indicate that human corneal endothelial cells in vivo are arrested in the G1-phase and have not exited from the cell cycle. Successful outgrowth in culture of human corneal endothelial cells in vitro and the establishment of the immortalized human endothelial cell line, provide strong evidence that corneal endothelial cells retain proliferative capacity. Experiments with cell culture ex vivo demonstrate that corneal endothelial cells cultured from young donors grow more robustly than those from older donors, and cells cultured from peripheral area of corneas show greater cell density than central regions. Studies have demonstrated that in vitro human corneal endothelia undergo mitotic changes in response to stimulation of growth promoting agents,such as growth factors, EDTA and extracelluar matrix. Identification of corneal endothelial stem cells and isolation and culture of human endothelial precursor cells in vitro will be beneficial for further investigation regarding the mechanism of corneal endothelial regeneration as well as corneal endothelial cells in vitro culture.%原发性和继发性角膜内皮失代偿导致角膜基质水肿、角膜混浊和视力下降,其发生的病理生理基础在于成年人角膜内皮细胞失去增殖能力,损

  4. Acute corneal hydrops during pregnancy with spontaneous resolution after corneal cross-linking for keratoconus: a case report.

    Science.gov (United States)

    Stock, Ricardo Alexandre; Thumé, Thaís; Bonamigo, Elcio Luiz

    2017-02-25

    Keratoconus may progress to acute corneal hydrops even after cross-linking. In some cases, keratoconus progresses during pregnancy. In this report, we present a case of a patient with increased anterior stromal resistance after cross-linking that would favor nonprogression of keratoconus during pregnancy. We report that cross-linking is likely to have had a protective effect in a white pregnant patient with acute corneal hydrops who showed rapid improvement, as documented by corneal topography. Improvement occurred within 8 days, whereas up to 250 days are reported in the literature. No keratoconus progression occurred in the 20-month follow-up period. Cross-linking failed to prevent the occurrence of acute corneal hydrops after rupture of Descemet's membrane but most likely helped to accelerate the resolution of the condition. Corneal hardening resulting from cross-linking may have also contributed to stabilizing keratoconus during pregnancy.

  5. Autofluorescence imaging of macular pigment: influence and correction of ocular media opacities

    Science.gov (United States)

    Sharifzadeh, Mohsen; Obana, Akira; Gohto, Yuko; Seto, Takahiko; Gellermann, Werner

    2014-09-01

    The healthy adult human retina contains in its macular region a high concentration of blue-light absorbing carotenoid compounds, known as macular pigment (MP). Consisting of the carotenoids lutein, zeaxanthin, and meso-zeaxanthin, the MP is thought to shield the vulnerable tissue layers in the retina from light-induced damage through its function as an optical attenuator and to protect the tissue cells within its immediate vicinity through its function as a potent antioxidant. Autofluorescence imaging (AFI) is emerging as a viable optical method for MP screening of large subject populations, for tracking of MP changes over time, and for monitoring MP uptake in response to dietary supplementation. To investigate the influence of ocular media opacities on AFI-based MP measurements, in particular, the influence of lens cataracts, we conducted a clinical trial with a large subject population (93 subjects) measured before and after cataract surgery. General AFI image contrast, retinal blood vessel contrast, and presurgery lens opacity scores [Lens Opacities Classification System III (LOCS III)] were investigated as potential predictors for image degradation. These clinical results show that lens cataracts can severely degrade the achievable pixel contrasts in the AFI images, which results in nominal MP optical density levels that are artifactually reduced. While LOCS III scores and blood vessel contrast are found to be only a weak predictor for this effect, a strong correlation exists between the reduction factor and the image contrast, which can be quantified via pixel intensity histogram parameters. Choosing the base width of the histogram, the presence or absence of ocular media opacities can be determined and, if needed, the nominal MP levels can be corrected with factors depending on the strength of the opacity.

  6. The heritability of glaucoma-related traits corneal hysteresis, central corneal thickness, intraocular pressure, and choroidal blood flow pulsatility.

    Directory of Open Access Journals (Sweden)

    Ellen E Freeman

    Full Text Available PURPOSE: The purpose of this work was to investigate the heritability of potential glaucoma endophenotypes. We estimated for the first time the heritability of the pulsatility of choroidal blood flow. We also sought to confirm the heritability of corneal hysteresis, central corneal thickness, and 3 ways of measuring intraocular pressure. METHODS: Measurements were performed on 96 first-degree relatives recruited from Maisonneuve-Rosemont Hospital in Montreal. Corneal hysteresis was determined using the Reichert Ocular Response Analyser. Central corneal thickness was measured with an ultrasound pachymeter. Three measures of intraocular pressure were obtained: Goldmann-correlated and corneal compensated intraocular pressure using the Ocular Response Analyser, and Pascal intraocular pressure using the Pascal Dynamic Contour Tonometer. The pulsatility of choroidal blood velocity and flow were measured in the sub-foveolar choroid using single-point laser Doppler flowmetry (Oculix. We estimated heritability using maximum-likelihood variance components methods implemented in the SOLAR software. RESULTS: No significant heritability was detected for the pulsatility of choroidal blood flow or velocity. The Goldman-correlated, corneal compensated, and Pascal measures of intraocular pressure measures were all significantly heritable at 0.94, 0.79, and 0.53 after age and sex adjustment (p = 0.0003, p = 0.0023, p = 0.0239. Central corneal thickness was significantly heritable at 0.68 (p = 0.0078. Corneal hysteresis was highly heritable but the estimate was at the upper boundary of 1.00 preventing us from giving a precise estimate. CONCLUSION: Corneal hysteresis, central corneal thickness, and intraocular pressure are all heritable and may be suitable as glaucoma endophenotypes. The pulsatility of choroidal blood flow and blood velocity were not significantly heritable in this sample.

  7. [New stimulants of corneal reparative regeneration].

    Science.gov (United States)

    Egorov, E A; Kalinin, N I; Kiiasov, A P

    1999-01-01

    The efficacy of corneregel, a drug containing pantothenic acid, a component of coenzyme A, in healing of corneal wounds has been evaluated. The study was carried out on 19 rabbits (38 eyes) with standard corneal defect made with a 5-mm trephine for lamellar transplantation of the cornea, divided into 2 groups: 1) instillations of corneregel (10 eyes) and 0.25% levomycetin solution (10 eyes) and 2) 20% solcoseryl gel (9 eyes) and 0.25% levomycetin (9 eyes). Time course of changes were evaluated by biomicroscopy (fluorescent test), histologically (hematoxylin-eosin staining), and immunohistochemically after 1, 2, 4, 7, 30, and 90 days. Proliferative activity was studied by expression of the proliferating cell nuclear antigen and the migration capacity of cells by expression of alpha-smooth muscle actin. The terms of epithelialization were as follows: corneregel 10 +/- 7 h, 20% solcoseryl gel 108 +/- 10 h, levomycetin 124 +/- 6.93 h. Earlier epithelialization in the corneregel group was apparently due to increased expression of alpha-smooth muscle actin and increase in the cell migration capacity. Hence, corneregel is recommended for practical use as a stimulant of reparative regeneration of the cornea.

  8. Bilateral Keratectasia 34 Years after Corneal Transplant

    Directory of Open Access Journals (Sweden)

    Xavier Valldeperas

    2010-07-01

    Full Text Available We report the clinical findings of a patient with severe bilateral keratectasia 34 years after a penetrating keratoplasty (PK in both eyes. An otherwise healthy 67-year-old man complained of deterioration of the eyesight in both eyes over the last 6 months. The patient was diagnosed with bilateral keratoconus at the age of 32 years, and he underwent a bilateral PK. At presentation, visual acuity was 20/200 in the right eye and light perception in the left eye. A Pentacam pachymetric map revealed a central pachymetry of 720 µm in the right eye and of 710 µm in the left eye, as well as an average paracentral pachymetry of 436 and 270 µm in the 9-mm zone in the right and the left eye, respectively. Corneal topography revealed bilateral irregular and asymmetric bowing with generalized steepening and high corneal power. We describe a case of bilateral keratectasia 34 years after PK in a patient who was originally diagnosed with bilateral keratoconus.

  9. Femtosecond laser's application in the corneal surgery

    Directory of Open Access Journals (Sweden)

    Shu-Liang Wang

    2015-10-01

    Full Text Available With the rapid development over the past two decades,femtosecond(10-15slasers(FShas become a new application in ophthalmic surgery. As laser power is defined as energy delivered per unit time, decreasing the pulse duration to femtosecond level(100fsnot only increases the power delivered but also decreases the fluence threshold for laser induced optical breakdown. In ablating tissue, FS has an edge over nanosecond lasers as there is minimal collateral damage from shock waves and heat conduction during surgical ablation. Thus, application of FS has been widely spread, from flap creation for laser-assisted in situ keratomileusis(LASIKsurgery, cutting of donor and recipient corneas in keratoplasty, creation of pockets for intracorneal ring implantation. FS applied in keratoplasty is mainly used in making graft and recipient bed, and can exactly cut different tissue of keratopathy. FS can also cut partial tissue of cornea, even if it is under the moderate corneal macula and corneal edema condition.

  10. IOL Power Calculation after Corneal Refractive Surgery

    Directory of Open Access Journals (Sweden)

    Maddalena De Bernardo

    2014-01-01

    Full Text Available Purpose. To describe the different formulas that try to overcome the problem of calculating the intraocular lens (IOL power in patients that underwent corneal refractive surgery (CRS. Methods. A Pubmed literature search review of all published articles, on keyword associated with IOL power calculation and corneal refractive surgery, as well as the reference lists of retrieved articles, was performed. Results. A total of 33 peer reviewed articles dealing with methods that try to overcome the problem of calculating the IOL power in patients that underwent CRS were found. According to the information needed to try to overcome this problem, the methods were divided in two main categories: 18 methods were based on the knowledge of the patient clinical history and 15 methods that do not require such knowledge. The first group was further divided into five subgroups based on the parameters needed to make such calculation. Conclusion. In the light of our findings, to avoid postoperative nasty surprises, we suggest using only those methods that have shown good results in a large number of patients, possibly by averaging the results obtained with these methods.

  11. Clinical utility of the KAMRA corneal inlay.

    Science.gov (United States)

    Naroo, Shehzad Anjam; Bilkhu, Paramdeep Singh

    2016-01-01

    The treatment of presbyopia has been the focus of much scientific and clinical research over recent years, not least due to an increasingly aging population but also the desire for spectacle independence. Many lens and nonlens-based approaches have been investigated, and with advances in biomaterials and improved surgical methods, removable corneal inlays have been developed. One such development is the KAMRA™ inlay where a small entrance pupil is exploited to create a pinhole-type effect that increases the depth of focus and enables improvement in near visual acuity. Short- and long-term clinical studies have all reported significant improvement in near and intermediate vision compared to preoperative measures following monocular implantation (nondominant eye), with a large proportion of patients achieving Jaeger (J) 2 to J1 (~0.00 logMAR to ~0.10 logMAR) at the final follow-up. Although distance acuity is reduced slightly in the treated eye, binocular visual acuity and function remain very good (mean 0.10 logMAR or better). The safety of the inlay is well established and easily removable, and although some patients have developed corneal changes, these are clinically insignificant and the incidence appears to reduce markedly with advancements in KAMRA design, implantation technique, and femtosecond laser technology. This review aims to summarize the currently published peer-reviewed studies on the safety and efficacy of the KAMRA inlay and discusses the surgical and clinical outcomes with respect to the patient's visual function.

  12. Corneal power evaluation after myopic corneal refractive surgery using artificial neural networks.

    Science.gov (United States)

    Koprowski, Robert; Lanza, Michele; Irregolare, Carlo

    2016-11-15

    Efficacy and high availability of surgery techniques for refractive defect correction increase the number of patients who undergo to this type of surgery. Regardless of that, with increasing age, more and more patients must undergo cataract surgery. Accurate evaluation of corneal power is an extremely important element affecting the precision of intraocular lens (IOL) power calculation and errors in this procedure could affect quality of life of patients and satisfaction with the service provided. The available device able to measure corneal power have been tested to be not reliable after myopic refractive surgery. Artificial neural networks with error backpropagation and one hidden layer were proposed for corneal power prediction. The article analysed the features acquired from the Pentacam HR tomograph, which was necessary to measure the corneal power. Additionally, several billion iterations of artificial neural networks were conducted for several hundred simulations of different network configurations and different features derived from the Pentacam HR. The analysis was performed on a PC with Intel(®) Xeon(®) X5680 3.33 GHz CPU in Matlab(®) Version 7.11.0.584 (R2010b) with Signal Processing Toolbox Version 7.1 (R2010b), Neural Network Toolbox 7.0 (R2010b) and Statistics Toolbox (R2010b). A total corneal power prediction error was obtained for 172 patients (113 patients forming the training set and 59 patients in the test set) with an average age of 32 ± 9.4 years, including 67% of men. The error was at an average level of 0.16 ± 0.14 diopters and its maximum value did not exceed 0.75 dioptres. The Pentacam parameters (measurement results) providing the above result are tangential anterial/posterior. The corneal net power and equivalent k-reading power. The analysis time for a single patient (a single eye) did not exceed 0.1 s, whereas the time of network training was about 3 s for 1000 iterations (the number of neurons in the hidden layer was 400).

  13. Hypercalcemia Leads to Delayed Corneal Wound Healing in Ovariectomized Rats.

    Science.gov (United States)

    Nagai, Noriaki; Ogata, Fumihiko; Kawasaki, Naohito; Ito, Yoshimasa; Funakami, Yoshinori; Okamoto, Norio; Shimomura, Yoshikazu

    2015-01-01

    Hypercalcemia is often observed in postmenopausal women as well as in patients with primary hyperparathyroidism or malignant tumors. In this study, we investigated the relationship between calcium ion (Ca(2+)) levels in lacrimal fluid and the rate of corneal wound healing in hypercalcemia using ovariectomized (OVX) rat debrided corneal epithelium. We also determined the effects of Ca(2+) levels on cell adhesion, proliferation and viability in a human cornea epithelial cell line (HCE-T). The calcium content in bones of OVX rats decreased after ovariectomy. Moreover, the Ca(2+) content in the blood of OVX rats was increased 1 month after ovariectomy, and decreased. The Ca(2+) content in the lacrimal fluid of OVX rats was also increased after ovariectomy, and then decreased similarly as in blood. Corneal wound healing in OVX rats was delayed in comparison with Sham rats (control rats), and a close relationship was observed between the Ca(2+) levels in lacrimal fluid and the rate of corneal wound healing in Sham and OVX rats (y=-0.7863x+8.785, R=0.78, n=25). In addition, an enhancement in Ca(2+) levels caused a decrease in the viability in HCE-T cells. It is possible that enhanced Ca(2+) levels in lacrimal fluid may cause a decrease in the viability of corneal epithelial cells, resulting in a delay in corneal wound healing. These findings provide significant information that can be used to design further studies aimed at reducing corneal damage of patients with hypercalcemia.

  14. 2-YEAR EXPERIENCE OF CORNEAL COLLAGEN CROSSLINKING IN KERATOCONUS TREATMENT

    Directory of Open Access Journals (Sweden)

    D. D. Dement’ev

    2015-01-01

    Full Text Available Aim. To assess reliability, efficacy, and stability of corneal collagen crosslinking (CXL results for stage I‑II keratoconus.Patients and methods. 2‑year (2012-2014 results of CXL were analyzed. CXL was performed on 20 eyes of 15 patients (13 men and 2 women, mean age 31 years. Stage 1 keratoconus was diagnosed in 13 eyes, stage 2 keratoconus was diagnosed in 2 eyes. Primary stage 1‑2 keratoconus was diagnosed in 17 eyes, keratoconus after corneal refractive surgery (LASIK, radial keratotomy was diagnosed in 3 eyes. Preoperative and postoperative examination included uncorrected (UCVA and best-corrected (BCVA visual acuity measurement, pachymetry, corneal topography (total astigmatism measurement, and biomicroscopy. Follow-up period varied from 1 to 24 months.Results. All patients reported on vision improvement. Preoperatively, mean UCVA and BCVA were 0.4 and 0.64, respectively. Postoperatively, mean UCVA and BCVA were 0.49 and 0.66, respectively. Preoperatively and postoperatively, total astigmatism was 2.1 D and 2.0 D, respectively, while mean central corneal thickness was 454 μm and 447 μm, respectively.Conclusions. Corneal collagen crosslinking for stage 1‑2 keratoconus provides mild UCVA and BCVA improvement, decrease in total astigmatism and central corneal thickness. CXL provides stable results of treatment of primary stage 1‑2 keratoconus and keratoconus after corneal refractive surgery. 

  15. Characteristics of corneal lens chitin in dragonfly compound eyes.

    Science.gov (United States)

    Kaya, Murat; Sargin, Idris; Al-Jaf, Ivan; Erdogan, Sevil; Arslan, Gulsin

    2016-08-01

    Chitin in the compound eyes of arthropods serves as a part of the visual system. The quality of chitin in such highly specialised body parts deserves more detailed examination. Chitin in the corneal (ommatidial) lenses of dragonfly (Sympetrum fonscolombii) compound eyes was isolated by using the classical chemical method. The chitin content of the corneal lenses was determined to be quite high (20.3±0.85%). The FT-IR analysis showed that corneal lens chitin was in the α-form as found in all arthropod species where mechanical strength is required. The surface morphology analysis by scanning electron microscopy revealed that the outer part of corneal lenses consisted of long chitin fibrils with regular arrays of papillary structures while the smoother inner part had concentric lamellated chitin formation with shorter chitin nanofibrils. Chitinase enzymatic digestion studies, elemental analysis results and the degree of acetylation value showed the purity of chitin samples from corneal lens. The maximum degradation temperature value of the corneal lens chitin was observed at 369.2°C. X-ray analysis revealed that corneal lens chitin has high crystallinity index; 96.4%. Identification of chitin found in ommaditia of insect compound eyes can provide insights into insect vision and chitin-based optical material design studies.

  16. Cytocompatibility of Three Corneal Cell Types with Amniotic Membrane

    Institute of Scientific and Technical Information of China (English)

    CHENJian-su; CHENRui; XUJin-tang; DINGYong; ZHAOSong-bin; LISui-lian

    2004-01-01

    Rabbit limbal corneal epithelial cells, corneal endothelial cells and keratocytes were cultured on amniotic membrane. Phase contrast microscope examination was performed daily. Histological and scan electron microscopic examinations were carried out to observe the growth, arrangement and adhesion of cultivated cells. Results showed that three corneal cell types seeded on amniotic membrane grew well and had normal cell morphology. Cultured cells attached firmly on the surface of amniotic membrane. Corneal epithelial cells showed singular layer or stratification. Cell boundaries were formed and tightly opposed. Corneal endothelial cells showed cobblestone or polygonal morphologic characteristics that appeared uniform in size. The cellular arrangement was compact. Keratocytes elongated and showed triangle or dendritic morphology with many intercellular joints which could form networks. In conclusion, amniotic membrane has good scaffold property, diffusion effect and compatibility with corneal cells. The basement membrane side of amniotic membrane facilitated the growth of corneal epithelial cells and endothelial cells and cell junctions were tightly developed. The spongy layer of amniotic membrane facilitated the growth of keratocytes and intercellular joints were rich. Amniotic membrane is an ideal biomaterial for layering tissue engineered cornea.

  17. Investigation of the value of a photographic tool to measure self-perception of enamel opacities

    Directory of Open Access Journals (Sweden)

    Davies Gill M

    2012-10-01

    Full Text Available Abstract Background The standard measurement of oral conditions that are mainly of cosmetic concern can be carried out by a trained clinical professional, or they can be assessed and reported by the individuals who may have the condition or be aware of others who have it. Enamel opacities of anterior teeth are examples of such a condition. At a public health level the interest is only about opacities that are of aesthetic concern, so the need for an index that records opacities that the public perceive to be a problem is clear. Measurement methods carried out by highly trained professionals, using unnatural conditions are not indicated at this level. This study reports on the testing of a novel epidemiological tool that aims to report on the prevalence and impact of self-perceived enamel opacities in a population of young adolescents. Methods A dental health survey was carried out using a random sample of 12-year-old school pupils during 2008/09 by Primary Care Organisations (PCOs in England. This included the use of a novel self-perception tool which aimed to measure individual’s self-perception of the presence and impact of enamel opacities to produce population measures. This tool comprised questions asking about the presence of white marks on their teeth and whether these marks bothered the volunteers and a sheet of grouped photographs of anterior teeth showing opacities ranging from TF 0, TF 1–2 to TF 2–3. Volunteers were asked which of the groups of photographs looked more like their own teeth. Examining teams from a convenience sample of 3 PCOs from this survey agreed to undertake additional measurements to assess the value of the self-perception tool. Volunteer pupils were asked the questions on a second occasion, some time after the first and clinical examiners recorded their assessments of the most closely matching set of photographs of the volunteers on two occasions. Results The tool was feasible to use, with 74% of pupils

  18. Impact of facial conformation on canine health: corneal ulceration.

    Directory of Open Access Journals (Sweden)

    Rowena M A Packer

    Full Text Available Concern has arisen in recent years that selection for extreme facial morphology in the domestic dog may be leading to an increased frequency of eye disorders. Corneal ulcers are a common and painful eye problem in domestic dogs that can lead to scarring and/or perforation of the cornea, potentially causing blindness. Exaggerated juvenile-like craniofacial conformations and wide eyes have been suspected as risk factors for corneal ulceration. This study aimed to quantify the relationship between corneal ulceration risk and conformational factors including relative eyelid aperture width, brachycephalic (short-muzzled skull shape, the presence of a nasal fold (wrinkle, and exposed eye-white. A 14 month cross-sectional study of dogs entering a large UK based small animal referral hospital for both corneal ulcers and unrelated disorders was carried out. Dogs were classed as affected if they were diagnosed with a corneal ulcer using fluorescein dye while at the hospital (whether referred for this disorder or not, or if a previous diagnosis of corneal ulcer(s was documented in the dogs' histories. Of 700 dogs recruited, measured and clinically examined, 31 were affected by corneal ulcers. Most cases were male (71%, small breed dogs (mean± SE weight: 11.4±1.1 kg, with the most commonly diagnosed breed being the Pug. Dogs with nasal folds were nearly five times more likely to be affected by corneal ulcers than those without, and brachycephalic dogs (craniofacial ratio <0.5 were twenty times more likely to be affected than non-brachycephalic dogs. A 10% increase in relative eyelid aperture width more than tripled the ulcer risk. Exposed eye-white was associated with a nearly three times increased risk. The results demonstrate that artificially selecting for these facial characteristics greatly heightens the risk of corneal ulcers, and such selection should thus be discouraged to improve canine welfare.

  19. Impact of facial conformation on canine health: corneal ulceration.

    Science.gov (United States)

    Packer, Rowena M A; Hendricks, Anke; Burn, Charlotte C

    2015-01-01

    Concern has arisen in recent years that selection for extreme facial morphology in the domestic dog may be leading to an increased frequency of eye disorders. Corneal ulcers are a common and painful eye problem in domestic dogs that can lead to scarring and/or perforation of the cornea, potentially causing blindness. Exaggerated juvenile-like craniofacial conformations and wide eyes have been suspected as risk factors for corneal ulceration. This study aimed to quantify the relationship between corneal ulceration risk and conformational factors including relative eyelid aperture width, brachycephalic (short-muzzled) skull shape, the presence of a nasal fold (wrinkle), and exposed eye-white. A 14 month cross-sectional study of dogs entering a large UK based small animal referral hospital for both corneal ulcers and unrelated disorders was carried out. Dogs were classed as affected if they were diagnosed with a corneal ulcer using fluorescein dye while at the hospital (whether referred for this disorder or not), or if a previous diagnosis of corneal ulcer(s) was documented in the dogs' histories. Of 700 dogs recruited, measured and clinically examined, 31 were affected by corneal ulcers. Most cases were male (71%), small breed dogs (mean± SE weight: 11.4±1.1 kg), with the most commonly diagnosed breed being the Pug. Dogs with nasal folds were nearly five times more likely to be affected by corneal ulcers than those without, and brachycephalic dogs (craniofacial ratio ulcer risk. Exposed eye-white was associated with a nearly three times increased risk. The results demonstrate that artificially selecting for these facial characteristics greatly heightens the risk of corneal ulcers, and such selection should thus be discouraged to improve canine welfare.

  20. Using corneal topography design personalized cataract surgery programs

    Directory of Open Access Journals (Sweden)

    Jin-Ou Huang

    2014-08-01

    Full Text Available AIM:To investigate how to design personalized cataract surgery programs to achieve surgical correction of preoperative corneal astigmatism with surgical astigmatism under the guidance of corneal topography, improve postoperative visual quality and reduce the cost of treatment. METHODS: Totally 202 cases(226 eyescataract patients were divided into randomized treatment group and individualized treatment group. According to the method and location of the incision, randomized treatment group were divided into 8 groups. Surgical astigmatism after different incision were calculated with the use of preoperative and postoperative corneal astigmatism through vector analysis method. Individualized treatment groups were designed personably for surgical method with reference of every surgically induced astigmatism, the surgical method chooses the type of surgical incision based on close link between preoperative corneal astigmatism and surgically induced astigmatism, and the incision was located in the steep meridian. The postoperative corneal astigmatism of individualized treatment group was observed. RESULTS: Postoperative corneal astigmatism of individualized treatment group were lower than that of 3.0mm clear corneal tunnel incision in the randomized treatment group, there were statistically significance difference, while with 3.0mm sclera tunnel incision group there were no statistically significance difference. After 55.8% of patients with the use of individualized surgical plan could undergo the operation of extracapsular cataract extraction with relatively low cost and rigid intraocular lens implantation, the per capita cost of treatment could be reduced. CONCLUSION: Personalized cataract surgery programs are designed to achieve surgical correction of preoperative corneal astigmatism under the use of corneal topography, improve postoperative visual quality and reduce the cost of treatment.

  1. Methylene blue-related corneal edema and iris discoloration.

    Science.gov (United States)

    Timucin, Ozgur Bulent; Karadag, Mehmet Fatih; Aslanci, Mehmet Emin; Baykara, Mehmet

    2016-04-01

    We report the case of a 70-year-old female patient who developed corneal edema and iris discoloration following the inadvertent use of 1% methylene blue instead of 0.025% trypan blue to stain the anterior capsule during cataract phacoemulsification surgery. Copious irrigation was performed upon realization of incorrect dye use. Corneal edema and iris discoloration developed during the early postoperative period and persisted at 24-months follow-up. However, keratoplasty was not required. The intracameral use of 1% methylene blue has a cytotoxic effect on the corneal endothelium and iris epithelium. Copious irrigation for at least 30 min using an anterior chamber maintainer may improve outcomes.

  2. Repositioning of pedicle conjunctival flap performed for refractory corneal ulcer

    Directory of Open Access Journals (Sweden)

    Ashok Sharma

    2014-01-01

    Full Text Available A 50-year-old male was referred with a previous history of conjunctival flap (CF for a nonhealing fungal corneal ulcer with extreme corneal thinning in the right eye. The peritomy for the CF extended from 6:30 to 9:30 clock h on the cornea. The CF was disengaged, peritomy area deepithelialized, and CF was repositioned. He later underwent penetrating keratoplasty and achieved 20/40 best corrected visual acuity. The authors present a new concept for surgically repositioning CF s to the original site immediately after healing of the corneal ulcer.

  3. Repositioning of pedicle conjunctival flap performed for refractory corneal ulcer.

    Science.gov (United States)

    Sharma, Ashok; Mohan, Kanwar; Sharma, Rajan; Nirankari, Verinder S

    2014-01-01

    A 50-year-old male was referred with a previous history of conjunctival flap (CF) for a nonhealing fungal corneal ulcer with extreme corneal thinning in the right eye. The peritomy for the CF extended from 6:30 to 9:30 clock h on the cornea. The CF was disengaged, peritomy area deepithelialized, and CF was repositioned. He later underwent penetrating keratoplasty and achieved 20/40 best corrected visual acuity. The authors present a new concept for surgically repositioning CF s to the original site immediately after healing of the corneal ulcer.

  4. Septo-optic dysplasia with bilateral congenital corneal anesthesia.

    Science.gov (United States)

    Chow, Clement C; Kapur, Rashmi; Wood, Michael G; Setabutr, Pete; Tu, Elmer Y

    2009-10-01

    Septo-optic dysplasia, or de Morsier syndrome, is characterized by optic nerve hypoplasia with an absent septum pellucidum and/or pituitary abnormalities. Congenital corneal anesthesia is a rare disorder that has been associated with many neurological disorders. Here we present a patient with both conditions who was successfully treated with permanent lateral tarsorrhaphy and aggressive lubrication. To our knowledge, congenital corneal anesthesia has not been reported in association with septo-optic dysplasia. The purpose of this report is to make pediatric ophthalmologists aware of a potential association since the diagnosis of congenital corneal anesthesia is often difficult and delayed.

  5. UUnilateral corneal edema caused by a hidden foreign body.

    Science.gov (United States)

    Galvis, V; Tello, A; Frederick, G A; Laiton, A N

    2017-09-01

    A middle-aged adult male was referred to our institution due to unilateral corneal edema for a possible corneal transplant. At first, the patient denied a history of trauma. A small foreign body, which had been overlooked by the primary ophthalmologist, was detected by gonioscopy, embedded in the anterior chamber angle. It was successfully surgically removed and visual results were good. In any patient with unilateral unexplained corneal edema, it is necessary to rule out the presence of a foreign body in the anterior chamber. Copyright © 2016 Sociedad Española de Oftalmología. Publicado por Elsevier España, S.L.U. All rights reserved.

  6. An ab initio HCN/HNC rotational-vibrational line list and opacity function for astronomy

    Science.gov (United States)

    Harris, Gregory John

    HCN/HNC is an important molecule which is found throughout the universe. For example HCN/HNC is known to exist in comets, planetary atmospheres and the interstellar medium. HCN is also an important opacity source in carbon rich stars (C-stars). HCN masers have been observed in the circumstellar material around these C-stars and also in galaxies. Jorgensen and co-workers investigated model carbon star atmospheres in which they included HCN as an opacity source. They found that including a HCN opacity function had a remarkable effect: the atmosphere expanded by five times and the pressure of the atmosphere in the surface layers dropped by one or two orders of magnitude. This suggests that a full and detailed treatment of the rotational-vibrational spectrum of HCN/HNC could have a profound effect on the models of carbon stars, this provides the main motivation in this work. The temperatures of the stars in which HCN is an important opacity source Teff = 2000 - 3000 K. If HCN and HNC are in thermodynamic equilibrium it would be expected that HNC as well as HCN are found in significant populations. The transition dipoles of the fundamental bands of HNC are more than twice as strong as their HCN counter parts. These factors mean that both HCN and HNC will be considered, which makes a semiglobal treatment of the [H,C,N] system necessary. In this thesis an ab initio HCN/HNC linelist, from which accurate spectra and opacity functions can be calculated, is computed. Within this thesis I present least squares fits for ab initio semiglobal potential energy, dipole moment, relativistic correction and adiabatic correction surfaces. The potential energy surface (PES) is morphed for HNC geometries of the potential to improve the HNC representation of the surface. The PES and dipole moment surface (DMS) are used to perform quantum mechanical nuclear motion (rotational-vibrational) calculations with the DVR3D suite of codes. Preliminary calculations are made to optimise a ro

  7. Corneal modeling using conic section fits of PAR corneal topography system measurements

    Science.gov (United States)

    Zipper, Stanley; Manns, Fabrice; Fernandez, Viviana; Sandadi, Samith; Ho, Arthur; Parel, Jean-Marie A.

    2001-06-01

    The purpose of this study was to measure the average shape and variability of human corneas and to develop a tool for analyzing, height, curvature, and aberrations based on a conic section model. Fresh Eye Bank Eyes were placed in Dextran until the corneal thickness reached a physiological value. The eyes were placed in a custom made holder and measured using an intraoperative PAR Corneal Topography System (CTS) mounted on an operation microscope. Topography was measured before and after removal of the epithelium. A series of MATLAB functions were written to analyze the raw-z (height) data in polar coordinates. The functions fit conic sections to the PAR CTS data along hemi-meridians at 5 degree(s) intervals. The conic shape factor and apical radius were used to calculate and display the curvature. The dependence of these parameters with meridional position was examined.

  8. Corneal melanosis successfully treated using topical mitomycin-C and alcohol corneal epitheliectomy: a 3-year follow-up case report

    Directory of Open Access Journals (Sweden)

    Mehmet Balcı

    2015-08-01

    Full Text Available ABSTRACTWe report a case of primary acquired corneal melanosis without atypia associated with corneal haze in a patient with a history of limbal malignant melanoma and the effect of mitomycin-C. A 75-year-old woman with a history of limbal malignant melanoma presented with loss of vision in right eye. Corneal examination showed a patchy melanotic pigmentation with a central haze. Topical mitomycin-C improved visual acuity and corneal haze. However, the pigmented lesions persisted, and they were removed with alcohol corneal epitheliectomy. Histopathological examination demonstrated primary acquired melanosis without atypia. The lesions were successfully removed, and there were no recurrences during the follow-up period of 36 months. The association of conjunctival and corneal melanosis without atypia is a rare condition. In addition, co-existence of central corneal haze and melanosis may decrease visual acuity. Topical mitomycin-C and alcohol corneal epitheliectomy can be useful treatments in this condition.

  9. Corneal melanosis successfully treated using topical mitomycin-C and alcohol corneal epitheliectomy: a 3-year follow-up case report.

    Science.gov (United States)

    Balcı, Mehmet; Yağcı, Ramazan; Güler, Emre; Haltaş, Hacer; Duman, Rahmi; Hepşen, İbrahim F

    2015-01-01

    We report a case of primary acquired corneal melanosis without atypia associated with corneal haze in a patient with a history of limbal malignant melanoma and the effect of mitomycin-C. A 75-year-old woman with a history of limbal malignant melanoma presented with loss of vision in right eye. Corneal examination showed a patchy melanotic pigmentation with a central haze. Topical mitomycin-C improved visual acuity and corneal haze. However, the pigmented lesions persisted, and they were removed with alcohol corneal epitheliectomy. Histopathological examination demonstrated primary acquired melanosis without atypia. The lesions were successfully removed, and there were no recurrences during the follow-up period of 36 months. The association of conjunctival and corneal melanosis without atypia is a rare condition. In addition, co-existence of central corneal haze and melanosis may decrease visual acuity. Topical mitomycin-C and alcohol corneal epitheliectomy can be useful treatments in this condition.

  10. Intraoperative Corneal Thickness Changes during Pulsed Accelerated Corneal Cross-Linking Using Isotonic Riboflavin with HPMC

    Directory of Open Access Journals (Sweden)

    Ahmed M. Sherif

    2016-01-01

    Full Text Available Purpose. To evaluate corneal thickness changes during pulsed accelerated corneal cross-linking (CXL for keratoconus using a new isotonic riboflavin formula. Methods. In this prospective, interventional, clinical study patients with grades 1-2 keratoconus (Amsler-Krumeich classification underwent pulsed accelerated (30 mW/cm2 CXL after application of an isotonic riboflavin solution (0.1% with HPMC for 10 minutes. Central corneal thickness (CCT measurements were taken using ultrasound pachymetry before and after epithelial removal, after riboflavin soaking, and immediately after completion of UVA treatment. Results. Twenty eyes of 11 patients (4 males, 7 females were enrolled. Mean patient age was 26±3 (range from 18 to 30 years. No intraoperative or postoperative complications were observed in any of the patients. Mean CCT was 507±35 μm (range: 559–459 μm before and 475±40 μm (range: 535–420 μm after epithelial removal (P<0.001. After 10 minutes of riboflavin instillation, there was a statistically significant decrease of CCT by 6.2% from 475±40 μm (range: 535–420 μm to 446±31 μm (range: 508–400 (P<0.005. There was no other statistically significant change of CCT during UVA irradiation. Conclusions. A significant decrease of corneal thickness was demonstrated during the isotonic riboflavin with HPMC application while there was no significant change during the pulsed accelerated UVA irradiation.

  11. Generation of corneal epithelial cells from induced pluripotent stem cells derived from human dermal fibroblast and corneal limbal epithelium.

    Directory of Open Access Journals (Sweden)

    Ryuhei Hayashi

    Full Text Available Induced pluripotent stem (iPS cells can be established from somatic cells. However, there is currently no established strategy to generate corneal epithelial cells from iPS cells. In this study, we investigated whether corneal epithelial cells could be differentiated from iPS cells. We tested 2 distinct sources: human adult dermal fibroblast (HDF-derived iPS cells (253G1 and human adult corneal limbal epithelial cells (HLEC-derived iPS cells (L1B41. We first established iPS cells from HLEC by introducing the Yamanaka 4 factors. Corneal epithelial cells were successfully induced from the iPS cells by the stromal cell-derived inducing activity (SDIA differentiation method, as Pax6(+/K12(+ corneal epithelial colonies were observed after prolonged differentiation culture (12 weeks or later in both the L1B41 and 253G1 iPS cells following retinal pigment epithelial and lens cell induction. Interestingly, the corneal epithelial differentiation efficiency was higher in L1B41 than in 253G1. DNA methylation analysis revealed that a small proportion of differentially methylated regions still existed between L1B41 and 253G1 iPS cells even though no significant difference in methylation status was detected in the specific corneal epithelium-related genes such as K12, K3, and Pax6. The present study is the first to demonstrate a strategy for corneal epithelial cell differentiation from human iPS cells, and further suggests that the epigenomic status is associated with the propensity of iPS cells to differentiate into corneal epithelial cells.

  12. Rovibrationally-resolved photodissociation of NH and application to the solar UV opacity

    Science.gov (United States)

    Shen, G.; Kuri, A.; Fontenla, J. M.; Stancil, P. C.; Wang, J. G.

    2014-05-01

    Rovibrationally-resolved photodissociation cross sections of NH have been evaluated using a combination of ab initio and experimentally derived potential curves and dipole transition moments. Here we present results for the three electronic transitions: 23Σ- interstellar gas, cross sections for X3Σ- (v = 0 , J = 0) to 23Σ- and 23 Π dominate, but for the high density and temperature conditions in stellar atmospheres, the LTE cross section to the A3 Π becomes competitive. Explicit application of the cross sections to the solar UV opacity will be presented. In particular, the NH photodissociation opacity is found to affect the non-LTE behavior of some species such as Cr I and V I. The work at UGA was partially supported by NASA grant HST-AR-11776.01-A. The work of JMF was supported by NASA LWS grant NNX09AJ22G. GS acknowledges travel support by the International Cooperation and Exchange Foundation of CAEP.

  13. Radiative ablation with two ionizing-fronts when opacity displays a sharp absorption edge

    CERN Document Server

    Poujade, Olivier; Vandenboomgaerde, Marc

    2014-01-01

    The interaction of a strong flux of photons with matter through an ionizing-front (I-front) is an ubiquitous phenomenon in the context of astrophysics and inertial confinement fusion (ICF) where intense sources of radiation put matter into motion. When the opacity of the irradiated material varies continuously in the radiation spectral domain, only one single I-front is formed. In contrast, as numerical simulations tend to show, when the opacity of the irradiated material presents a sharp edge in the radiation spectral domain, a second I-front (an edge-front) can form. A full description of the mechanism behind the formation of this edge-front is presented in this article. It allows to understand supernumerary shocks (edge-shocks), displayed by ICF simulations, that might affect the robustness of the design of fusion capsules in actual experiments. Moreover, it may have consequences in various domains of astrophysics where ablative flows occur.

  14. Time-Dependent Photoionization in a Dusty Medium II Evolution of Dust Distributions and Optical Opacities

    CERN Document Server

    Perna, R; Fiore, F; Perna, Rosalba; Lazzati, Davide; Fiore, Fabrizio

    2003-01-01

    The interaction of a radiation field with a dusty medium is a relevant issue in several astrophysical contexts. We use the time-dependent photoionization code in a dusty medium developed by Perna & Lazzati (2002), to study the modifications in the dust distribution and the relative optical opacities when a strong X-ray UV radiation flux propagates into a medium. We find that silicates are preferentially destroyed with respect to graphite, and the extinction curve becomes significantly flatter (hence implying less reddening), with the characteristic bump at lambda 2175 A highly suppressed, due to the destruction of the small graphite grains. This could explain the observational lack of such a feature in GRB afterglow and AGN spectra. For a very intense and highly variable source irradiating a compact and dense region, time variability in the optical opacity resulting from dust destruction can be observed on a relatively short timescale. We show that, under these circumstances, monitoring the time variabili...

  15. Utilitarian Opacity Model for Aggregate Particles in Protoplanetary Nebulae and Exoplanet Atmospheres

    CERN Document Server

    Cuzzi, Jeffrey N; Davis, Sanford S

    2013-01-01

    As small solid grains grow into larger ones in protoplanetary nebulae, or in the cloudy atmospheres of exoplanets, they generally form porous aggregates rather than solid spheres. A number of previous studies have used highly sophisticated schemes to calculate opacity models for irregular, porous particles with size much smaller than a wavelength. However, mere growth itself can affect the opacity of the medium in far more significant ways than the detailed compositional and/or structural differences between grain constituents once aggregate particle sizes exceed the relevant wavelengths. This physics is not new; our goal here is to provide a model that provides physical insight and is simple to use in the increasing number of protoplanetary nebula evolution, and exoplanet atmosphere, models appearing in recent years, yet quantitatively captures the main radiative properties of mixtures of particles of arbitrary size, porosity, and composition. The model is a simple combination of effective medium theory with...

  16. Opacity of Hot and Dense Plasmas of a Mixture using an Average-Atom Approach

    Institute of Scientific and Technical Information of China (English)

    袁建民

    2002-01-01

    An average-atom model is proposed to calculate the opacities of hot and dense plasmas of a mixture. A self-consistent scheme is used to reach the requirements of the same temperature and chemical potential for all kinds ofatoms in the mixtures, the same electron density at the boundaries between the atoms, and the electrical neutralitywithin each atomic sphere. The orbital energies and wavefunctions for the bound electrons are calculated withthe Dirac-Slater equations. The occupation numbers at each orbital of each kind of atom are determined by theFermi-Dirac distribution with the same chemical potential for all kinds of atoms. As an example, the opacity ofthe mixture of Au and Cd is calculated at a few temperatures and densities.

  17. Submillimeter fourier-transform spectrometer measurements of atmospheric opacity above mauna kea.

    Science.gov (United States)

    Serabyn, E; Weisstein, E W; Lis, D C; Pardo, J R

    1998-04-20

    We present accurately calibrated submillimeter atmospheric transmission spectra obtained with a Fourier-transform spectrometer at the Caltech Submillimeter Observatory on Mauna Kea, Hawaii. These measurements cover the 0.9-0.3-mm wavelength range and are the first in a series aimed at defining the terrestrial long-wave atmospheric transmission curve. The 4.1-km altitude of the Mauna Kea site provides access to extremely low zenith water-vapor columns, permitting atmospheric observations at frequencies well above those possible from sea level. We describe the calibration procedures, present our first well-calibrated transmission spectra, and compare our results with those of a single-layer atmospheric transmission model, AT. With an empirical best-fit continuum opacity term included, this simple single-layer model provides a remarkably good fit to the opacity data for H(2)O line profiles described by either van Vleck-Weisskopf or kinetic shapes.

  18. Opacities and Spectra of the r-process Ejecta from Neutron Star Mergers

    CERN Document Server

    Kasen, Daniel; Barnes, Jennifer

    2013-01-01

    Material ejected during (or immediately following) the merger of two neutron stars may assemble into heavy elements by the r-process. The subsequent radioactive decay of the nuclei can power electromagnetic emission similar to, but significantly dimmer than, an ordinary supernova. Identifying such events is an important goal of future transient surveys, offering new perspectives on the origin of r-process nuclei and the astrophysical sources of gravitational waves. Predictions of the transient light curves and spectra, however, have suffered from the uncertain optical properties of heavy ions. Here we consider the opacity of expanding r-process material and argue that it is dominated by line transitions from those ions with the most complex valence electron structure, namely the lanthanides. For a few representative ions, we run atomic structure models to calculate radiative data for tens of millions of lines. We find that the resulting r-process opacities are orders of magnitude larger than that of ordinary ...

  19. Evolution and chemical yields of AGB stars: effects of low-temperature opacities

    CERN Document Server

    Ventura, Paolo

    2009-01-01

    The studies focused on the Thermally-Pulsing Asymptotic Giant Branch phase experienced by low- and intermediate-mass stars are extremely important in many astrophysical contexts. In particular, a detailed computation of their chemical yields is essential for several issues, ranging from the chemical evolution of galaxies, to the mechanisms behind the formation of globular clusters. Among all the uncertainties affecting the theoretical modelling of this phase, and described in the literature, it remains to be fully clarified which results are severely affected by the use of inadequate low-temperature opacities, that are in most cases calculated on the basis of the original chemical composition of the stars, and do not consider the changes in the surface chemistry due to the occurrence of the third dredge-up and hot-bottom burning. Our investigation is aimed at investigating this point. By means of full evolutionary models including new set of molecular opacities computed specifically with the AESOPUS tool, we ...

  20. Automatic system for corneal ulcer diagnostic: II

    Science.gov (United States)

    Ventura, Liliane; Chiaradia, Caio; Faria de Sousa, Sidney J.

    1998-06-01

    Corneal Ulcer is a deepithelization of the cornea and it is a very common disease in agricultural countries. The clinician most used parameter in order to identify a favorable ulcer evolution is the regress of the affected area. However, this kind of evaluation is subjective, once just the horizontal and vertical axes are measured based on a graduated scale and the affected area is estimated. Also, the registration of the disease is made by photographs. In order to overcome the subjectiveness and to register the images in a more accessible way (hard disks, floppy disks, etc.), we have developed an automatic system in order to evaluate the affected area (the ulcer). An optical system is implemented in a Slit Lamp (SL) and connected to a CCD detector. The image is displayed in PC monitor by a commercial frame grabber and a dedicated software for determining the area of the ulcer (precision of 20 mm) has been developed.

  1. [Corneal collagen cross-linking for keratoconus].

    Science.gov (United States)

    Zotov, V V; Pashtaev, N P; Pozdeeva, N A

    2015-01-01

    Over the last decade, corneal collagen cross-linking (CXL) has become a conventional treatment method for progressive keratoconus. Laboratory studies have shown that CXL increases the diameter of collagen fibers and also the number of intra- and interfibrillar cross-links, thus, increasing biomechanical strength of the irradiated cornea. As confirmed by a series of clinical and randomized controlled trials, CXL is able to slow down and, perhaps, to stop the progression of keratoconus. In most post-CXL patients visual acuity improves, while keratometric readings, spherical equivalent, and higher order aberrations reduce. Although published results prove CXL effective in the treatment of progressive keratoconus, its late consequences are yet unknown. This article reviews the stages of CXL development and results of published experimental and clinical studies. Prospects for CXL modifications that do not require epithelial debridement are discussed.

  2. Another Risk From Cigarette Smoking: Corneal Burn

    Directory of Open Access Journals (Sweden)

    Volkan Hürmeriç

    2012-12-01

    Full Text Available A 21-year-old male presented with corneal injury in his left eye after one of his friends had moved his arm backwards and accidentally hit his eye with the lit end of a cigarette. Slit lamp examination revealed epithelial defect and significant stromal edema at the superior temporal quadrant of the cornea. Cigarette ashes were noted in his lashes and inferior conjunctival fornix at the initial examination in the emergency service. 6 weeks after the injury, slit lamp examination revealed stromal thinning and haze in the temporal part of the cornea. His best spectacle-corrected distance visual acuity was 20/25 with a refractive error of -6.75x135 diopters in the left eye. Our case demonstrates that ocular thermal injury due to cigarette smoking can cause serious damage to the ocular tissues. (Turk J Oph thal mol 2012; 42: 484-5

  3. Design and validation of a corneal bioreactor.

    Science.gov (United States)

    Leonard, Elissa K; Pai, Vincent H; Amberg, Philip; Gardner, Jens; Orwin, Elizabeth J

    2012-12-01

    Mechanical strain is an important signal that influences the behavior and properties of cells in a wide variety of tissues. Physiologically similar mechanical strain can revert cultured cells to a more normal phenotype. Here, we have demonstrated that 3% equibiaxial (EB) and uniaxial strains confer favorable protein expression in cultured rabbit corneal fibroblasts (RCFs), with approximately 35% and 65% reduction in expression of α-smooth muscle actin (α-SMA), respectively. We have designed a novel bioreactor that is capable of imparting up to 7% EB strain and up to 6% EB strain using a cornea-shaped post. Additional features of the bioreactor include the application of shear stress to cells in culture and the ability to image cells using optical coherence microscopy (OCM) without being removed from the system. Copyright © 2012 Wiley Periodicals, Inc.

  4. Putative Corneal Neuralgia Responding to Vitamin D Supplementation

    Directory of Open Access Journals (Sweden)

    Eric L. Singman

    2013-09-01

    Full Text Available A patient with putative corneal neuralgia was incidentally discovered to have hypovitaminosis D. Supplementation of vitamin D appears to have led to a resolution of the patient's pain, whereas other efforts to treat the patient were unsuccessful.

  5. Review of photokeratitis: Corneal response to ultraviolet radiation (UVR exposure*

    Directory of Open Access Journals (Sweden)

    L A. Moore

    2010-12-01

    Full Text Available The development of photokeratitis in response to natural solar ultraviolet radiation (UVR is prevalent in individuals participating in outdoor recreational activities in environments with high reflective surfaces, such as beach activities, water sports and snow skiing. Eye care practitioners (ECPs are frequently encouraged by manufacturers and researchers to recommend UVR-blocking eyewear in the form of sunglasses and contact lenses. However, little is known about the precise nature of the corneal tissue response in the development of photokeratitis. This paper reviews the mechanisms responsible for the development of photokeratitis. Clinical signs and symptoms of photokeratitis, UVR corneal threshold and action spectra, corneal cellular changes and ocular protection from corneal UVR exposure are discussed. The content of this article will be useful to ECPs in making appropriate recommendations when prescribing UVR-protec-tive eyewear. (S Afr Optom 2010 69(3 123-131

  6. Treatment of Corneal Lesions in Individuals with Vernal Keratoconjunctivitis

    Directory of Open Access Journals (Sweden)

    Naoki Kumagai

    2005-01-01

    Full Text Available Vernal keratoconjunctivitis, a severe form of allergic conjunctival disease, is characterized by the development of various types of corneal lesions in conjunction with proliferative changes in the conjunctiva. Expression of bioactive substances, such as chemokines and adhesion molecules, by corneal fibroblasts likely contribute to the formation of corneal lesions by promoting local infiltration, activation, and survival of immune cells. Proliferation and deposition of extracellular matrix by conjunctival fibroblasts also may provide conditions which support the activation and survival of immune cells. Topical administration of corticosteroids is the principal mode of treatment for conjunctival inflammation in individuals with vernal keratoconjunctivitis. In some individuals, however, the surgical removal of conjunctival giant papillae or of corneal plaques is indicated.

  7. Substratum topography modulates corneal fibroblast to myofibroblast transformation.

    Science.gov (United States)

    Myrna, Kathern E; Mendonsa, Rima; Russell, Paul; Pot, Simon A; Liliensiek, Sara J; Jester, James V; Nealey, Paul F; Brown, Donald; Murphy, Christopher J

    2012-02-01

    The transition of corneal fibroblasts to the myofibroblast phenotype is known to be important in wound healing. The purpose of this study was to determine the effect of topographic cues on TGFβ-induced myofibroblast transformation of corneal cells. Rabbit corneal fibroblasts were cultured on nanopatterned surfaces having topographic features of varying sizes. Cells were cultured in media containing TGFβ at concentrations ranging from 0 to 10 ng/mL. RNA and protein were collected from cells cultured on topographically patterned and planar substrates and analyzed for the myofibroblast marker α-smooth muscle actin (αSMA) and Smad7 expression by quantitative real time PCR. Western blot and immunocytochemistry analysis for αSMA were also performed. Cells grown on patterned surfaces demonstrated significantly reduced levels of αSMA (P fibroblast phenotype while pathologic microenvironmental alterations may be permissive for increased myofibroblast differentiation and the development of fibrosis and corneal haze.

  8. Shadow photogrammetric apparatus for the quantitative evaluation of corneal buttons.

    Science.gov (United States)

    Denham, D; Mandelbaum, S; Parel, J M; Holland, S; Pflugfelder, S; Parel, J M

    1989-11-01

    We have developed a technique for the accurate, quantitative, geometric evaluation of trephined and punched corneal buttons. A magnified shadow of the frontal and edge views of a corneal button mounted on the rotary stage of a modified optical comparator is projected onto the screen of the comparator and photographed. This process takes approximately three minutes. The diameters and edge profile at any meridian photographed can subsequently be analyzed from the film. The precision in measuring the diameters of well cut corneal buttons is +/- 23 microns, and in measuring the angle of the edge profile is +/- 1 degree. Statistical analysis of inter observer variability indicated excellent reproducibility of measurements. Shadow photogrammetry offers a standardized, accurate, and reproducible method for analysis of corneal trephination.

  9. CT opacity in the lungs was preceded by increased MDP activity on bone scintigraphy.

    Science.gov (United States)

    Song, Le; Zhang, Weifang; Zhang, Yanyan

    2014-11-01

    Elevated 99mTc-methylene diphosphonate (MDP) uptake in the left lung was demonstrated in a 41-year-old man with chronic lymphocytic leukemia. Lung infection was considered because the patient also had fever and pancytopenia. However, the thoracic CT performed the next day did not reveal abnormality which could explain the cause of left lung MDP activity. The repeated thoracic CTs weeks later demonstrated multiple ground-glass opacity in the left lung.

  10. Conceptual design of initial opacity experiments on the national ignition facility

    Science.gov (United States)

    Heeter, R. F.; Bailey, J. E.; Craxton, R. S.; Devolder, B. G.; Dodd, E. S.; Garcia, E. M.; Huffman, E. J.; Iglesias, C. A.; King, J. A.; Kline, J. L.; Liedahl, D. A.; McKenty, P. W.; Opachich, Y. P.; Rochau, G. A.; Ross, P. W.; Schneider, M. B.; Sherrill, M. E.; Wilson, B. G.; Zhang, R.; Perry, T. S.

    2017-02-01

    Accurate models of X-ray absorption and re-emission in partly stripped ions are necessary to calculate the structure of stars, the performance of hohlraums for inertial confinement fusion and many other systems in high-energy-density plasma physics. Despite theoretical progress, a persistent discrepancy exists with recent experiments at the Sandia Z facility studying iron in conditions characteristic of the solar radiative-convective transition region. The increased iron opacity measured at Z could help resolve a longstanding issue with the standard solar model, but requires a radical departure for opacity theory. To replicate the Z measurements, an opacity experiment has been designed for the National Facility (NIF). The design uses established techniques scaled to NIF. A laser-heated hohlraum will produce X-ray-heated uniform iron plasmas in local thermodynamic equilibrium (LTE) at temperatures eV and electron densities 21~\\text{cm}-3$ . The iron will be probed using continuum X-rays emitted in a ps, diameter source from a 2 mm diameter polystyrene (CH) capsule implosion. In this design, of the NIF beams deliver 500 kJ to the mm diameter hohlraum, and the remaining directly drive the CH capsule with 200 kJ. Calculations indicate this capsule backlighter should outshine the iron sample, delivering a point-projection transmission opacity measurement to a time-integrated X-ray spectrometer viewing down the hohlraum axis. Preliminary experiments to develop the backlighter and hohlraum are underway, informing simulated measurements to guide the final design.

  11. Limb-darkening opacity experiment using a laser-heated plasma

    Energy Technology Data Exchange (ETDEWEB)

    Hoffman, N.M.; Miller, L.W.; Mack, J.M.

    1978-10-01

    The limb-darkening technique, a method for measuring monochromatic opacity information, which has had successful astrophysical applications, is reviewed. The application of the technique to laser-produced plasmas in materials and regimes of temperature and density of interest to weapons designers is discussed, and the magnitude of the limb-darkening effect in such situations is estimated. Finally, an experimental study, now in progress, to evaluate the feasibility of this approach is described. 10 figures.

  12. Central Corneal Thickness in Adult Chinese

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    The central corneal thickness (CCT) in age 48 years or less of Chinese was characterized and its relationship with gender, age, refraction and intraocular pressure (IOP) was investigated.Right eyes of 1669 participants were included in this study (880 men, 52.7 % and 789 women,47.3 %). Mean age of the samples was 23.8±5.9 years. After the examination of corneal topography and refraction, Goldman applanation tonometry was carried out by one physician. Tonometric values were the mean of three consecutive readings. Subsequently, another physician carried out ultrasonic pachymetry with the DGH 2000 AP ultrasonic pachymeter. Six measuremen ts were made at the center of the cornea of each eye. The mean value was used for analysis. The results showed that mean CCT of male participants was 551.33± 34. 62 μm, 5.79 μm more than that of female participants. Linear regression analyses revealed that CCT was negatively related with age only in female and no association was found between refractive status and CCT. IOP was positively related to CCT, and there was a difference in IOP of 1.5 mmHg (1 mmHg=0. 133 kPa) per 100 μm difference in CCT. Ocular hypertension group was prone to have thicker cornea than average. The results indicated that in adult Chinese CCT tended to decrease with aging in female only. IOP measured by Goldmann tonometry was positively related with CCT so that CCT should be measured along with IOP.

  13. Clinical utility of the KAMRA corneal inlay

    Directory of Open Access Journals (Sweden)

    Naroo SA

    2016-05-01

    Full Text Available Shehzad Anjam Naroo, Paramdeep Singh Bilkhu Ophthalmic Research Group, School of Life & Health Sciences, Aston University, Birmingham, UK Abstract: The treatment of presbyopia has been the focus of much scientific and clinical research over recent years, not least due to an increasingly aging population but also the desire for spectacle independence. Many lens and nonlens-based approaches have been investigated, and with advances in biomaterials and improved surgical methods, removable corneal inlays have been developed. One such development is the KAMRA™ inlay where a small entrance pupil is exploited to create a pinhole-type effect that increases the depth of focus and enables improvement in near visual acuity. Short- and long-term clinical studies have all reported significant improvement in near and intermediate vision compared to preoperative measures following monocular implantation (nondominant eye, with a large proportion of patients achieving Jaeger (J 2 to J1 (~0.00 logMAR to ~0.10 logMAR at the final follow-up. Although distance acuity is reduced slightly in the treated eye, binocular visual acuity and function remain very good (mean 0.10 logMAR or better. The safety of the inlay is well established and easily removable, and although some patients have developed corneal changes, these are clinically insignificant and the incidence appears to reduce markedly with advancements in KAMRA design, implantation technique, and femtosecond laser technology. This review aims to summarize the currently published peer-reviewed studies on the safety and efficacy of the KAMRA inlay and discusses the surgical and clinical outcomes with respect to the patient’s visual function. Keywords: presbyopia, refractive surgery, implants, cornea

  14. Opacity measurement of a gold plasma at T{sub e} = 85 eV

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Jiyan; Yang Jiamin; Yang Guohong; Li Hang; Yuan Zheng; Zhao Yang; Xiong Gang; Bao Lihua; Huang Chenwu; Ding Yongkun; Zhang Baohan; Zheng Zhijian [Research Center of Laser Fusion, P. O. Box 919-986, Mianyang 621900 (China); Xu Yan; Wu Zheqing; Yan Jun [Institute of Applied Physics and Computational Mathematics, Beijing 100088 (China)

    2011-11-15

    The opacity of a gold plasma at the temperature of 85 eV and density of 0.02 g/cm{sup 3} was measured over the energy range from 150 eV to 1200 eV. The gold sample was heated by thermal x-ray radiation generated with a foam-baffled gold cavity. The sample transmission was obtained from the backlight, absorption and self-emission spectra measured by a time-gated, spatially resolved grating spectrometer, with the backlight and absorption spectra being measured simultaneously in a single shot and the self-emission in another shot. The temperature and density of the gold absorber were determined by the hydrodynamic simulation with Multi-1D code, which was partially tested by the reemission radiative flux measurements of the heated sample. This work permits the first test of opacity models over the photon energy range that dominates the Rosseland mean opacity at the temperature of interest for the inertial confinement fusion.

  15. Probing cosmic opacity at high redshifts with gamma-ray bursts

    CERN Document Server

    Holanda, R F L

    2014-01-01

    Probing the evolution of the universe at high redshifts with standard candles is a powerful way to discriminate dark energy models, where an open question nowadays is whether this component is constant or evolves with time. One possible source of ambiguity in this kind of analyses comes from cosmic opacity, which can mimick a dark enery behaviour. However, most tests of cosmic opacity have been restricted to the redshift range $z2$) for a flat $\\Lambda$CDM model. A possible degenerescence of the results with the adopted cosmological model is also investigated by considering a flat XCDM model. The limits on cosmic opacity in the redshift range $0

  16. Technical Note: Optical properties of desert dust with non-spherical particles: data incorporated to OPAC

    Directory of Open Access Journals (Sweden)

    P. Koepke

    2015-02-01

    Full Text Available Mineral desert dust particles in general are no spheres and assuming spherical particles, instead of more realistic shapes, has significant effects on modeled optical dust properties and so on the belonging remote sensing procedures for desert dust and the derived radiative forcing. Thus in a new version of the data base OPAC (Optical Properties of Aerosols and Clouds; Hess et al., 1998, the optical properties of the mineral particles are modeled describing the particles as spheroids with size dependent aspect ratio distributions, but with the size distributions and the spectral refractive indices not changed against the previous version of OPAC. The spheroid assumption strongly improves the scattering functions, but pays regard to the limited knowledge on particle shapes in an actual case. The relative deviations of the phase functions of non-spherical mineral particles from those of spherical particles are up to +60% at scattering angles of about 130° and up to −60% in the backscatter region, but the deviations are generally small for optical properties that are independent of the scattering angle. The improved version of OPAC (4.0 is freely available under http://www.rascin.net/

  17. Iron and molecular opacities and the evolution of Population I stars

    Science.gov (United States)

    Stothers, Richard B.; Chin, Chao-Wen

    1993-01-01

    Effects of recent opacity revisions on the evolution of Population I stars are explored over the range 1.5-60 solar masses. Opacity parameters considered include the angular momentum coupling scheme for iron, the relative iron abundance, the total metal abundance, and diatomic and triatomic molecular sources. Only the total metal abundance exerts an important control over the evolutionary tracks. Blue loops on the H-R diagram during core helium burning can be very sensitive to opacity, but only insofar as the simple formation or suppression of a blue loop is concerned. The blue loops are most robust for stellar masses around 10 solar masses. We confirm, from a comparison of stellar models with observational data, that the total metal abundance is close to solar and that convective core overshooting is likely to be very slight. The new models predict the existence of an iron convection zone in the envelope and a great widening of the main-sequence band in the H-R diagram at luminosities brighter than 100,000 solar luminosities.

  18. Changes Of Dust Opacity With Density in the Orion A Molecular Cloud

    CERN Document Server

    Roy, Arabindo; Polychroni, Danae; Bontemps, Sylvain; Abergel, Alain; Andre, Philippe; Arzoumanian, Doris; Di Francesco, James; Hill, Tracey; Konyves, Vera; Nguyen-Luong, Quang; Pezzuto, Stefano; Schneider, Nicola; Testi, Leonardo; White, Glenn

    2012-01-01

    We have studied the opacity of dust grains at submillimeter wavelengths by estimating the optical depth from imaging at 160, 250, 350, and 500 um from the Herschel Gould Belt Survey and comparing this to a column density obtained from the 2MASS-derived color excess E(J-Ks). Our main goal was to investigate the spatial variations of the opacity due to "big" grains over a variety of environmental conditions and thereby quantify how emission properties of the dust change with column (and volume) density. The central and southern areas of the Orion A molecular cloud examined here, with NH ranging from 1.5X10^21 cm^-2 to 50X10^21 cm^-2, are well suited to this approach. We fit the multi-frequency Herschel spectral energy distributions (SEDs) of each pixel with a modified blackbody to obtain the temperature, T, and optical depth, \\tau(1200), at a fiducial frequency of 1200 GHz (250 um). Using a calibration of NH/E(J-Ks)for the interstellar medium (ISM) we obtained the opacity (dust emission cross-section per H nucl...

  19. The effect of preheating and opacity on the sorption and solubility of a composite resin.

    Science.gov (United States)

    Castro, Fabrício Luscino Alves de; Pazinatto, Flávia Bittencourt; de Lima, Érick; Cesar, Paulo Francisco; Reges, Rogério Vieira

    2016-01-01

    This study evaluated the influence of material opacity and preheating on the sorption and solubility of a composite resin material. A commercially available composite resin and an 8 × 2-mm circular metallic matrix were used to fabricate a total of 60 specimens in 6 shades, of which 3 had conventional opacity (CA2, CA3, and CA3.5) and 3 were opaque (OA2, OA3, and OA3.5). Specimens were prepared at a room temperature of 25°C or preheated to 60°C (n = 5 per shade at each temperature). The specimens were weighed 3 times: M1, dried for 24 hours at 37°C; M2, stored for 7 days in 75% ethanol at 37°C; and M3, dried for an additional 24 hours at 37°C. The weights were used to calculate the sorption and solubility of the composite resin and were analyzed using 2-way analysis of variance and Tukey tests (α = 5%). Composite resin specimens heated at 60°C yielded lower values of sorption and solubility than did specimens prepared at 25°C (P composite shades were found to be similar (P > 0.05), except for shade CA2, which presented a greater mean solubility value than OA2 (P = 0.004). Therefore, preheating was beneficial, as it lowered both the sorption and solubility of the evaluated composite resin, but opacity had little effect on these properties.

  20. The assessment of lens opacity postmortem and its implication in forensics.

    Science.gov (United States)

    Stemberga, Valter; Petaros, Anja; Kovacevic, Damir; Coklo, Miran; Simicevic, Neven; Bosnar, Alan

    2013-11-01

    Visual impairment, mostly due to cataracts, has been demonstrated to be an important factor associated with traffic accidents. Although vision screening is standard procedure during licensing in order to prevent motor vehicle accidents, an eye exam is not typically administered after an accident has already occurred. Postmortem assessment of lens opacity in victims of car accidents would provide helpful information for attesting to the liability of the parties in specific accidents, determining the circumstances of the accident, and developing preventive measures for both drivers and pedestrians alike. In this paper, we explore the use of different methods and their limitations for assessing lens opacity postmortem. We discuss the possible use and benefits of a simple, but as-yet untested method: retrobulbar translucency. The method would be based on the recording of shadows formed by opaque regions of the lens while the eye is illuminated from the back with a rigid source of light. The efficacy and objectivity of the method, its reproducibility, and the inter- and intra-observer error should be tested before implementing such a technique to be regularly used to determine lens opacity in cadavers.

  1. 3.5-Year Monitoring of 225 GHz Opacity at the Summit of Greenland

    CERN Document Server

    Matsushita, Satoki; Martin-Cocher, Pierre L; Chen, Ming-Tang; Ho, Paul T P; Inoue, Makoto; Koch, Patrick M; Paine, Scott N; Turner, David D

    2016-01-01

    We present the 3.5-yr monitoring results of 225 GHz opacity at the summit of the Greenland ice sheet (Greenland Summit Camp) at an altitude of 3200 m using a tipping radiometer. We chose this site as our submillimeter telescope (Greenland Telescope; GLT) site, because its location offers favorable baselines to existing submillimeter telescopes for global-scale VLBI. The site shows a clear seasonal variation with the average opacity lower by a factor of two during winter. For the winter quartiles of 25% and 50%, the Greenland site is about 10%-30% worse than the ALMA or the South Pole sites. Estimated atmospheric transmission spectra in winter season are similar to the ALMA site at lower frequencies (450 GHz) than those at the ALMA site. This is due to the lower altitude of the Greenland site. Nevertheless, half of the winter time at the Greenland site can be used for astronomical observations at frequencies between 450 GHz and 1000 GHz with opacities 10% transmittance in the THz (1035 GHz, 1350 GHz, and 1500 ...

  2. Opacity and Color Changes of Light-Cured Ideal Makoo (IDM

    Directory of Open Access Journals (Sweden)

    M.Ghavam

    2004-03-01

    Full Text Available Statement of Problem: Esthetic materials undergo some physical and mechanical changes,during their service in oral cavity.Purpose: The aim of this study was the evaluation of the color and opacity stability of Ideal Makoo (IDM composites and compare it with Tetric ceram.Material and methods: Fifteen disk shaped samples of each material was divided into three groups of five. Different aging treatments were applied to each group. The contrast ratio of 1mm thickness and rE of the samples were evaluated at base line and after aging,using CIE system and Data Flash spectrophotometer. All the samples were kept at 37°C.Results: Baseline opacity of IDM was relatively high (77.60%±8.6. Both materials showed increased opacity after aging. The highest rE belonged to IDM samples of B group, which was significantly more than Tetric Ceram (P<0.05. Tetric Ceram, also showed some degree of color change (rE=4.60 and 5.79, on black and white background,respectively, which is noticeable clinically.Conclusion: The research showed that IDM can not be a reliable esthetic material, unless some improvements in the chemical composition will be achieved.

  3. Knoop microhardness and FT-Raman evaluation of composite resins: influence of opacity and photoactivation source

    Directory of Open Access Journals (Sweden)

    Luis Gustavo Barrotte Albino

    2011-06-01

    Full Text Available The aim of this study was to evaluate the degree of conversion by Knoop microhardness (KHN and FT-Raman spectroscopy (FTIR of one nanofilled (Filtek Supreme-3M-ESPE [FS] and one microhybrid composite (Charisma-Heraeus-Kulzer [CH], each with different opacities, namely enamel, dentin, and translucent, which were photo-activated by a quartz-tungsten-halogen lamp (QTH and a light-emitting diode (LED. Resin was bulk inserted into a disc-shaped mold that was 2.0 mm thick and 4 mm in diameter, obtaining 10 samples per group. KHN and FTIR values were analyzed by two-way ANOVA and Tukey's tests (α = 0.05. Nanofilled resin activated by a LED presented higher microhardness values than samples activated by a QTH for dentin opacity (p < 0.05. The microhybrid resin showed no differences in KHN or FTIR values with different activation sources or opacity. The nanofilled dentin and enamel resins showed lower FTIR values than the translucent resin. The KHN values of the translucent resins were not influenced by the light source.

  4. An Analysis of Source Tilting and Sub-cell Opacity Sampling for IMC

    Energy Technology Data Exchange (ETDEWEB)

    Wollaeger, Ryan T. [Los Alamos National Laboratory; Urbatsch, Todd J. [Los Alamos National Laboratory; Wollaber, Allan B. [Los Alamos National Laboratory; Densmore, Jeffery D. [Los Alamos National Laboratory

    2012-08-02

    Implicit Monte Carlo (IMC) is a stochastic method for solving the radiative transfer equations for multiphysics application with the material in local thermodynamic equilibrium. The IMC method employs a fictitious scattering term that is computed from an implicit discretization of the material temperature equation. Unfortunately, the original histogram representation of the temperature and opacity with respect to the spatial domain leads to nonphysically fast propagation of radiation waves through optically thick material. In the past, heuristic source tilting schemes have been used to mitigate the numerical teleportation error of the radiation particles in IMC that cause this overly rapid radiation wave propagation. While improving the material temperature profile throughout the time duration, these tilting schemes alone do not generally alleviate the teleportation error to suitable levels. Another means of potentially reducing teleportation error in IMC is implementing continuous sub-cell opacities based on sub-cell temperature profiles. We present here an analysis of source tilting and continuous sub-cell opacity sampling applied to various discretizations of the temperature equation. Through this analysis, we demonstrate that applying both heuristics does not necessarily yield more accurate results if the discretization of the material equation is inconsistent with the Monte Carlo sub-cell transport.

  5. Literature Review of OPAC2.0 During 2005 - 2009 in China%2005—2010年OPAC2.0国内文献研究综述

    Institute of Scientific and Technical Information of China (English)

    顾磊

    2011-01-01

    This paper gives a comprehensive literature review of OPAC2.0 during 2005 -2010 in China, which summarizes the philosophy, the overall functions and contents, the core functions, the applied techniques and the construction approach of OPAC2.0. According to the research results, the basic theory research on the OPAC2.0 in China is rich, but the practice research is relatively poor.%对2005—2010年“国内OPAC2.0”的相关研究文献进行搜集与分析,总结OPAC2.0的理念、整体功能和内容、核心功能、采用的技术及实现途径等国内发展现状。从以上研究的成果来看,我国OPAC2.0的研究在基本理论方面的探讨趋近成熟,内容丰富,但是关于实际应用方面的研究还较欠缺。

  6. The Active Metabolite of Leflunomide A771726 Inhibits Corneal Neovascularization

    Institute of Scientific and Technical Information of China (English)

    Mingchang ZHANG; Nian HAO; Fang BIAN

    2008-01-01

    The effects of A771726, the active metabolite of leflunomide, on experimental rat corneal neovascularization (NV) in vivo and on cultured human umbilical vein endothelial cells in vitro were studied. The corneal NV was induced by alkali burn in 40 SD rats. The rats were randomly divided into 4 groups with 10 rats in each group. Group A was treated with 0.9% sodium chloride (control group), and group B, group C and group D were given different concentrations of A771726 eye drops (0.5%,l.0%,2.0% respectively) 4 times daily during days 0-28. The occurrence and development of corneal NV were observed at 4,7,14,21 and 28 day after alkali burn by a slit lamp microscope. The cultured human umbilical vein endothelial cells (ECV-304) were incubated with A771726 solution at different concentrations (20,40,80,160,320μmol/L) for 36h. The proliferation of cells was assessed by methyl thiazolyl tetrazolium (MTT), and the expression of proliferating cell nuclear antigen (PCNA) in cells was detected by using immunofluorescence under the laser confocal microscope. The rat model showed that the onset of corneal NV was delayed and progression of corneal NV was inhibited in the groups C and D. The corneal NV areas in groups C and D were significantly smaller than in groups A and B (P0.05). A771726 solution (≥40μmol/L) could inhibit proliferation of human umbilical vein endothelial cells and decrease the expression of PCNA in cells significantly. A771726, as the active metabolite of leflunomide, strongly prevented corneal NV induced by alkali burn in the in vivo model, and inhibited proliferation of human umbilical vein endothelial cells in the in vitro model. Therefore, A771726 may serve as an angiogenic inhibitor in the treatment of corneal NV.

  7. Pilot Study of Corneal Sensitivity and Its Association in Keratoconus.

    Science.gov (United States)

    Mandathara, Preeji S; Stapleton, Fiona J; Kokkinakis, Jim; Willcox, Mark D P

    2017-02-01

    To evaluate corneal sensitivity and its association with other clinical parameters in keratoconus. Twenty-four subjects with keratoconus aged between 18 and 65 years were recruited in this cross-sectional study. Ocular symptoms, corneal topography, tear variables such as tear osmolarity, volume and lower tear meniscus height, ocular surface staining, central sensitivity threshold (CST), and corneal subepithelial nerve mapping were obtained. Association between central CST and other clinical variables was examined using the Spearman correlation coefficient. Partial correlation was performed to control for effects of confounding factors. Data from the most severe eye of each subject were included in analyses. Based on the maximum simulated keratometry (Kmax) reading, subjects were graded as having mild (N = 11; K max ≤ 52 D) or severe (N = 13; K max > 52 D) keratoconus. Central corneal sensitivity was lower (ie, increased CST) in the severe keratoconus group compared with that in the mild keratoconus group (median, interquartile range: 1.09; 0.60-19.66 vs. 0.51; 0.39-1.51 g/mm, P = 0.035). In bivariate correlations, reduced corneal sensitivity in keratoconus was associated with age (ρ = 0.42, P = 0.040), disease duration (ρ = 0.49, P = 0.015) and severity (ρ = 0.44; P = 0.032), lower central nerve fiber density (ρ = -0.68, P = 0.014), contact lens wear (ρ = 0.44; P = 0.025), and contact lens tolerance (ρ = 0.46; P = 0.033). After adjusting for contact lens wear, reduced corneal sensitivity was negatively associated with ocular symptoms (ρ = -0.426, P = 0.048) and pain sensitivity (ρ = -0.423, P = 0.045) and positively associated with corneal staining (ρ = 0.52, P = 0.011). Altered corneal sensitivity in keratoconus affected ocular symptoms and ocular surface health, which may have significant impact on the success of management options for keratoconus.

  8. [The use of iontophoresis in corneal crosslinking technique].

    Science.gov (United States)

    Stanca, Horia T; Tabacaru, Bogdana

    2013-01-01

    Iontophoresis is a method of facilitating the penetration of a drug through an intact tissue in the presence of an low intensity electrical current. In corneal crosslinking technique, iontophoresis is used for transepitelial impregnation of cornea with riboflavin. Compared to passive technique of corneal impregnation, iontophoresis shortens the time needed for impregnation, the time of exposure to UVA radiation and does not require de-epithelialisation.

  9. On fractional Bessel equation and the description of corneal topography

    CERN Document Server

    Okrasiński, Wojciech

    2012-01-01

    In this note we apply a modified fractional Bessel differential equation to the problem of describing corneal topography. We find the solution in terms of the power series. This solution has an interesting behavior at infinity which is a generalization of the classical results for modified Bessel function of order 0. Our model fits the real corneal geometry data with an error of order of a few per cent.

  10. ROLE OF CORNEAL COLLAGEN CROSS LINKING IN KERATOCONUS

    OpenAIRE

    Atul; Superna; Bhimasankar; Vijayleela

    2015-01-01

    To evaluate the outcome of collagen cross linkage using riboflavin 0.1% and ultraviolet A radiation of a wavelength 370nm . PURPOSE : To determine the effect of collagen cross linking for keratoconus on pachymetry , corneal topography, uncorrected visual acuity, specular count, IOP at 1, 3, 6 months . METHODS : The current study was designed as a prospective interventional trial of corneal collagen cross - linking in subjects w...

  11. Hypertonic saline in the treatment of corneal jellyfish stings.

    Science.gov (United States)

    Yu Yao, Hsin; Cho, Ta Hsiung; Lu, Ching Hsiang; Lin, Feng Chi; Horng, Chi Ting

    2016-02-01

    A 20-year-old male soldier was hit by the jellyfish. The ophthalmic examination revealed that epithelial keratitis and corneal oedema in the right eye. We prescribed 3% NaCl eyedrops and 0.3% Norfloxacin eyedrops in the treatment of the corneal jellyfish stings. Two weeks later, the cornea in the right eye healed. In this case report, 3% NaCl eyedrops was effective in the treatment of acute phase of jellyfish stings of the cornea.

  12. Morphometrics of corneal growth in chicks raised in constant light.

    Science.gov (United States)

    Wahl, Christina; Li, Tong; Choden, Tsering; Howland, Howard

    2009-03-01

    In this study we wish to augment our understanding of the effect of environment on corneal growth and morphology. To understand how corneal development of chicks raised in constant light differs from that of 'normal' eyes exposed to cyclic periods of light and dark, white Leghorn chicks were raised under either constant light (approximately 700 lux at cage top) or in 12 h light/12 h dark conditions for up to 12 weeks after hatching. To determine whether corneal expansion is uniform, some birds from each group received corneal tattoos for periodic photographic assessment. By 16 days of age, constant light corneas weighed less than light/dark regimen corneas [7.39 +/- 0.35 mg (SE) vs. 8.47 mg +/- 0.26 mg SE wet weight, P < or = 0.05], and corresponding differences were seen in corneal dry weights. Spatial expansion of the corneal surface was uniform in both groups, but the rate of expansion was slower in constant light chicks [0.0327 +/- 0.009 (SE) vs. 0.144 +/- 0.018 (SE) mm(2) day(-1) for normal chicks, P < or = 0.001]. At 1 day of age, there were 422 +/- 12.5 (SE) stromal cells 0.01 mm(-2) in the central cornea and 393 +/- 21.5 (SE) stromal cells 0.01 mm(-2 )peripherally. Although this difference is not statistically significant, the cell densities in the central cornea were always larger than those of the peripheral cornea in all eight measurements over a 10.5-week period, and this difference is significant (P < or = 0.008, binomial test). Light/dark regimen birds show no such consistent difference in cell densities between central and peripheral corneas. Thus, the density distribution of corneal stromal cells of chicks grown in constant light differs from that of normal chicks. Taken together, all these observations suggest that diurnal cycles of light and darkness are necessary for normal corneal growth.

  13. Electrically assisted delivery of macromolecules into the corneal epithelium

    OpenAIRE

    HAO, JINSONG; Li, S. Kevin; Liu, Chia-Yang; Kao, Winston W. Y.

    2009-01-01

    Electrically assisted delivery is noninvasive and has been investigated in a number of ocular drug delivery studies. The objectives of this study were to examine the feasibility of electrically assisted delivery of macromolecules such as small interfering RNA (siRNA) into the corneal epithelium, to optimize the iontophoresis and electroporation methods, and to study the mechanisms of corneal iontophoresis for macromolecules. Anodal and cathodal iontophoresis, electroporation and their combina...

  14. Solar neutrinos and the influences of opacity, thermal instability, additional neutrino sources, and a central black hole on solar models

    Science.gov (United States)

    Stothers, R. B.; Ezer, D.

    1972-01-01

    Significant quantities that affect the internal structure of the sun are examined for factors that reduce the temperature near the sun's center. The four factors discussed are: opacity, central black hole, thermal instability, and additional neutrino sources.

  15. Corneal Cell Morphology in Keratoconus: A Confocal Microscopic Observation

    Science.gov (United States)

    Ghosh, Somnath; Mutalib, Haliza Abdul; Kaur, Sharanjeet; Ghoshal, Rituparna; Retnasabapathy, Shamala

    2017-01-01

    Purpose To evaluate corneal cell morphology in patients with keratoconus using an in vivo slit scanning confocal microscope. Methods A cross-sectional study was conducted to evaluate the corneal cell morphology of 47 keratoconus patients and 32 healthy eyes without any ocular disease. New keratoconus patients with different disease severities and without any other ocular co-morbidity were recruited from the ophthalmology department of a public hospital in Malaysia from June 2013 to May 2014. Corneal cell morphology was evaluated using an in vivo slit-scanning confocal microscope. Qualitative and quantitative data were analysed using a grading scale and the Nidek Advanced Visual Information System software, respectively. Results The corneal cell morphology of patients with keratoconus was significantly different from that of healthy eyes except in endothelial cell density (P = 0.072). In the keratoconus group, increased level of stromal haze, alterations such as the elongation of keratocyte nuclei and clustering of cells at the anterior stroma, and dark bands in the posterior stroma were observed with increased severity of the disease. The mean anterior and posterior stromal keratocyte densities and cell areas among the different stages of keratoconus were significantly different (P 0.05) among the three stages of keratoconus. Conclusion Confocal microscopy observation showed significant changes in corneal cell morphology in keratoconic cornea from normal healthy cornea. Analysis also showed significant changes in different severities of keratoconus. Understanding the corneal cell morphology changes in keratoconus may help in the long-term monitoring and management of keratoconus. PMID:28894403

  16. Corneal pain activates a trigemino-parabrachial pathway in rats.

    Science.gov (United States)

    Aicher, Sue A; Hegarty, Deborah M; Hermes, Sam M

    2014-03-06

    Corneal pain is mediated by primary afferent fibers projecting to the dorsal horn of the medulla, specifically the trigeminal nucleus caudalis. In contrast to reflex responses, the conscious perception of pain requires transmission of neural activity to higher brain centers. Ascending pain transmission is mediated primarily by pathways to either the thalamus or parabrachial nuclei. We previously showed that some corneal afferent fibers preferentially contact parabrachial-projecting neurons in the rostral pole of the trigeminal nucleus caudalis, but the role of these projection neurons in transmitting noxious information from the cornea has not been established. In the present study, we show that noxious stimulation of the corneal surface activates neurons in the rostral pole of the nucleus caudalis, including parabrachially projecting neurons that receive direct input from corneal afferent fibers. We used immunocytochemical detection of c-Fos protein as an index of neuronal activation after noxious ocular stimulation. Animals had previously received injections of a retrograde tracer into either thalamic or parabrachial nuclei to identify projection neurons in the trigeminal dorsal horn. Noxious stimulation of the cornea induced c-Fos in neurons sending projections to parabrachial nuclei, but not thalamic nuclei. We also confirmed that corneal afferent fibers identified with cholera toxin B preferentially target trigeminal dorsal horn neurons projecting to the parabrachial nucleus. The parabrachial region sends ascending projections to brain regions involved in emotional and homeostatic responses. Activation of the ascending parabrachial system may explain the extraordinary salience of stimulation of corneal nociceptors.

  17. Analysis of corneal esthesia in patients undergoing photorefractive keratectomy

    Directory of Open Access Journals (Sweden)

    Elmar Torres Neto

    2015-12-01

    Full Text Available ABSTRACT Purpose: To quantitatively analyze corneal esthesia in patients undergoing photorefractive keratectomy (PRK surgery. Methods: Forty-five patients selected for PRK in one eye underwent corneal esthesia using a Cochet-Bonnet esthesiometer preoperatively and 30 and 90 days postoperatively. Patients with a refractive diopter error of 4 or greater received intraoperative 0.02% mitomycin C for 20 s. Results: Twenty-four (53.3% of the 45 eyes received intraoperative 0.02% mitomycin. Decreased sensitivity was observed on postoperative day 30. By postoperative day 90, corneal esthesia had normalized but remained 14.9% lower than preoperative levels. In the mitomycin group, no recovery of corneal esthesia to normal sensitivity levels was observed. The mean esthesiometer level was 39.2 mm on postoperative day 90 (P<0.001. Conclusions: The results of the present study demonstrate recovery of corneal esthesia to normal levels at 90 days postoperatively in patients who did not receive mitomycin C. In patients administered mitomycin C, a 23.59% reduction in the corneal touch threshold was observed compared with preoperative levels indicating a failure of recovery to normal levels.

  18. Congenital Corneal Anesthesia and Neurotrophic Keratitis: Diagnosis and Management

    Directory of Open Access Journals (Sweden)

    Flavio Mantelli

    2015-01-01

    Full Text Available Neurotrophic keratitis (NK is a rare degenerative disease of the cornea caused by an impairment of corneal sensory innervation, characterized by decreased or absent corneal sensitivity resulting in epithelial keratopathy, ulceration, and perforation. The aetiopathogenesis of corneal sensory innervation impairment in children recognizes the same range of causes as adults, although they are much less frequent in the pediatric population. Some extremely rare congenital diseases could be considered in the aetiopathogenesis of NK in children. Congenital corneal anesthesia is an extremely rare condition that carries considerable diagnostic and therapeutic problems. Typically the onset is up to 3 years of age and the cornea may be affected in isolation or the sensory deficit may exist as a component of a congenital syndrome, or it may be associated with systemic somatic anomalies. Accurate diagnosis and recognition of risk factors is important for lessening long-term sequelae of this condition. Treatment should include frequent topical lubrication and bandage corneal or scleral contact lenses. Surgery may be needed in refractory cases. The purpose of this review is to summarize and update data available on congenital causes and treatment of corneal hypo/anesthesia and, in turn, on congenital NK.

  19. Corneal lesion as the initial manifestation of tyrosinemia type II.

    Science.gov (United States)

    Tsai, Chun-Pin; Lin, Pei-Yu; Lee, Ni-Chung; Niu, Dau-Ming; Lee, Shui-Mei; Hsu, Wen-Ming

    2006-06-01

    Tyrosinemia type II (Richner-Hanhart syndrome) is a rare autosomal recessive disease with deficiency of tyrosine aminotransferase and subsequently increasing level of serum tyrosine. We report the case of a 2-year-old girl who was referred due to bilateral corneal lesions. Slit-lamp examination showed small granular white deposits arranged in a dendritic pattern in the superficial central cornea of both eyes. Physical examination revealed painful, non-pruritic, hyperkeratotic plaques on the soles, palms and fingertips. Mental evaluation demonstrated developmental delay for her age. Blood examination revealed serum tyrosine level to be 1868 microM (normal range, 30-110 microM), which decreased to 838 microM with 2-month diet on tyrosine and phenylalanine restriction. The corneal and skin lesions resolved completely. However, the corneal deposits recurred a month later as her mother failed to strictly control the diet because the little girl was losing weight and activity. With specific formula and adjusted diet regimen, the corneal lesions decreased again. Corneal pseudodendritic deposits may be the initial manifestation in patients with tyrosinemia type II. Early diagnosis and intervention with diet control are crucial for preventing permanent visual and developmental deficits. Corneal deposits can be one of the parameters in monitoring the efficacy of diet control.

  20. Azithromycin (AZM) treatment increases survival of high risk corneal allotransplants

    Science.gov (United States)

    Medina, Carlos A.; Rowe, Alexander M.; Yun, Hongmin; Knickelbein, Jared E.; Lathrop, Kira L.; Hendricks, Robert L.

    2012-01-01

    Purpose To test the therapeutic efficacy of AZM, a macrolide antibiotic for prolonging murine “high risk” corneal allograft survival. Methods Fully MHC mismatched corneas were transplanted from C57BL/6 donors to BALB/c recipients with suture-induced vascularized “high risk” corneal beds. Recipient mice were either not treated or treated with topical AZM, oral AZM, or both. Evaluation of graft vascularization and clarity was performed in masked fashion. Lymph nodes were excised and analyzed for CD4, FoxP3, and CD44 by flow cytometry; and for T cell priming by proliferation and cytokine production in mixed lymphocyte cultures. Corneal whole mounts were evaluated by confocal microscopy. Results The incidence of graft rejection in the control group (81.8%) was significantly reduced by AZM treatment (18.2% topical, 21.7% oral, 33.3% topical + oral), although corneal vascularization was not affected by treatment. The frequency of corneas that retained complete clarity following transplantation was higher in the AZM treated groups. Reduced graft rejection in the AZM treated groups was not associated with a reduced allospecific T cell response or increased frequency of T regulatory cells. Conclusions AZM is effective in prolonging survival of “high risk” corneal allografts by an as yet undefined mechanism that does not appear to involve modulation of corneal neovascularization or allo-specific T cell priming. PMID:23407315