WorldWideScience

Sample records for core noise diagnostics

  1. Studies on WWER core diagnostics

    International Nuclear Information System (INIS)

    Lunin, G.L.; Mitin, V.I.; Bulavin, V.V.

    1987-01-01

    The reliability and safety of nuclear power plants have decisive meaning under the situation that nuclear power generation steadily increases, and among various measures aiming at ensuring the reliability and safety in the operation of nuclear power plants, the countermeasures for protecting reactor core, main process equipment and high pressure circuits from damage have the important role, and the monitoring of condition and the organization of forecast, which are carried out continuously or periodically during the operation of nuclear power stations using the diagnostic expert system specially developed for the purpose, are included in them. Such monitoring enables the early detection of mechanical damage, increase of vibration, defects caused during operation and so on in reactor cores and primary and secondary circuits, and the continuous watching of defect developments. Also boiling in a core is detected, the place of abnormality occurrence is identified, and the intensity and characteristics of boiling are determined, thus the occurrence of dangerous condition is prevented. The developments of an in-core monitoring system and noise diagnostic systems are reported. (Kako, I.)

  2. Development and application of reactor noise diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Karlsson, Joakim K.H

    1999-04-01

    A number of problems in reactor noise diagnostics have been investigated within the framework of the present thesis. The six papers presented cover three relatively different areas, namely the use of analytical calculations of the neutron noise in simple reactor models, some aspects of boiling water reactor (BWR) stability and diagnostics of core barrel motion in pressurized water reactors (PWRs). The noise induced by small vibrations of a strong absorber has been the subject of several previous investigations. For a conventional {delta}-function source model, the equations can not be linearized in the traditional manner. Thus, a new source model, which is called the {epsilon}/d model, was developed. The correct solution has been derived in the {epsilon}/d model for both 1-D and 2-D reactor models. Recently, several reactor diagnostic problems have occurred which include a control rod partially inserted into the reactor core. In order to study such problems, we have developed an analytically solvable, axially non-homogenous, 2-D reactor model. This model has also been used to study the noise induced by a rod maneuvering experiment. Comparisons of the noise with the results of different reactor kinetic approximations have yielded information on the validity of the approximations in this relatively realistic model. In case of an instability event in a BWR, the noise may consist of one or several co-existing modes of oscillation and besides the fundamental mode, a regional first azimuthal mode has been observed in e.g. the Swedish BWR Ringhals-1. In order to determine the different stability characteristics of the different modes separately, it is important to be able to decompose the noise into its mode constituents. A separation method based on factorisation of the flux has been attempted previously, but without success. The reason for the failure of the factorisation method is the presence of the local component of the noise and its axial correlation properties. In

  3. Development and application of reactor noise diagnostics

    International Nuclear Information System (INIS)

    Karlsson, Joakim K.H.

    1999-04-01

    A number of problems in reactor noise diagnostics have been investigated within the framework of the present thesis. The six papers presented cover three relatively different areas, namely the use of analytical calculations of the neutron noise in simple reactor models, some aspects of boiling water reactor (BWR) stability and diagnostics of core barrel motion in pressurized water reactors (PWRs). The noise induced by small vibrations of a strong absorber has been the subject of several previous investigations. For a conventional δ-function source model, the equations can not be linearized in the traditional manner. Thus, a new source model, which is called the ε/d model, was developed. The correct solution has been derived in the ε/d model for both 1-D and 2-D reactor models. Recently, several reactor diagnostic problems have occurred which include a control rod partially inserted into the reactor core. In order to study such problems, we have developed an analytically solvable, axially non-homogenous, 2-D reactor model. This model has also been used to study the noise induced by a rod maneuvering experiment. Comparisons of the noise with the results of different reactor kinetic approximations have yielded information on the validity of the approximations in this relatively realistic model. In case of an instability event in a BWR, the noise may consist of one or several co-existing modes of oscillation and besides the fundamental mode, a regional first azimuthal mode has been observed in e.g. the Swedish BWR Ringhals-1. In order to determine the different stability characteristics of the different modes separately, it is important to be able to decompose the noise into its mode constituents. A separation method based on factorisation of the flux has been attempted previously, but without success. The reason for the failure of the factorisation method is the presence of the local component of the noise and its axial correlation properties. In the paper

  4. Enhanced Core Noise Modeling for Turbofan Engines

    Science.gov (United States)

    Stone, James R.; Krejsa, Eugene A.; Clark, Bruce J.

    2011-01-01

    This report describes work performed by MTC Technologies (MTCT) for NASA Glenn Research Center (GRC) under Contract NAS3-00178, Task Order No. 15. MTCT previously developed a first-generation empirical model that correlates the core/combustion noise of four GE engines, the CF6, CF34, CFM56, and GE90 for General Electric (GE) under Contract No. 200-1X-14W53048, in support of GRC Contract NAS3-01135. MTCT has demonstrated in earlier noise modeling efforts that the improvement of predictive modeling is greatly enhanced by an iterative approach, so in support of NASA's Quiet Aircraft Technology Project, GRC sponsored this effort to improve the model. Since the noise data available for correlation are total engine noise spectra, it is total engine noise that must be predicted. Since the scope of this effort was not sufficient to explore fan and turbine noise, the most meaningful comparisons must be restricted to frequencies below the blade passage frequency. Below the blade passage frequency and at relatively high power settings jet noise is expected to be the dominant source, and comparisons are shown that demonstrate the accuracy of the jet noise model recently developed by MTCT for NASA under Contract NAS3-00178, Task Order No. 10. At lower power settings the core noise became most apparent, and these data corrected for the contribution of jet noise were then used to establish the characteristics of core noise. There is clearly more than one spectral range where core noise is evident, so the spectral approach developed by von Glahn and Krejsa in 1982 wherein four spectral regions overlap, was used in the GE effort. Further analysis indicates that the two higher frequency components, which are often somewhat masked by turbomachinery noise, can be treated as one component, and it is on that basis that the current model is formulated. The frequency scaling relationships are improved and are now based on combustor and core nozzle geometries. In conjunction with the Task

  5. Research program in reactor core diagnostics with neutron noise methods: Stage 3. Final report

    International Nuclear Information System (INIS)

    Pazsit, I.; Garis, N.S.; Karlsson, J.; Racz, A.

    1997-09-01

    Stage 3 of the program has been executed 96-04-12. The long term goal is to develop noise methods for identification and localization of perturbations in reactor cores. The main parts of the program consist of modelling the noise source, calculation of the space- and frequency dependent transfer function, calculation of the neutron noise via a convolution of the transfer function of the system and the noise source, i.e. the perturbation, and finally finding an inversion or unfolding procedure to determine noise source parameters from the neutron noise. Most previous work is based on very simple (analytical) reactor models for the calculation of the transfer function as well as analytical unfolding methods. The purpose of this project is to calculate the transfer function in a more realistic model as well as elaborating powerful inversion methods that do not require analytical transfer functions. The work in stage 3 is described under the following headlines: Further investigation of simplified models for the calculation of the neutron noise; Further investigation of methods based on neural networks; Further investigation of methods for detecting the vibrations and impacting of detectors; Application of static codes for determination of the neutron noise using the adiabatic approximation

  6. DART Core/Combustor-Noise Initial Test Results

    Science.gov (United States)

    Boyle, Devin K.; Henderson, Brenda S.; Hultgren, Lennart S.

    2017-01-01

    Contributions from the combustor to the overall propulsion noise of civilian transport aircraft are starting to become important due to turbofan design trends and advances in mitigation of other noise sources. Future propulsion systems for ultra-efficient commercial air vehicles are projected to be of increasingly higher bypass ratio from larger fans combined with much smaller cores, with ultra-clean burning fuel-flexible combustors. Unless effective noise-reduction strategies are developed, combustor noise is likely to become a prominent contributor to overall airport community noise in the future. The new NASA DGEN Aero0propulsion Research Turbofan (DART) is a cost-efficient testbed for the study of core-noise physics and mitigation. This presentation gives a brief description of the recently completed DART core combustor-noise baseline test in the NASA GRC Aero-Acoustic Propulsion Laboratory (AAPL). Acoustic data was simultaneously acquired using the AAPL overhead microphone array in the engine aft quadrant far field, a single midfield microphone, and two semi-infinite-tube unsteady pressure sensors at the core-nozzle exit. An initial assessment shows that the data is of high quality and compares well with results from a quick 2014 feasibility test. Combustor noise components of measured total-noise signatures were educed using a two-signal source-separation method an dare found to occur in the expected frequency range. The research described herein is aligned with the NASA Ultra-Efficient Commercial Transport strategic thrust and is supported by the NASA Advanced Air Vehicle Program, Advanced Air Transport Technology Project, under the Aircraft Noise Reduction Subproject.

  7. Core Noise: Overview of Upcoming LDI Combustor Test

    Science.gov (United States)

    Hultgren, Lennart S.

    2012-01-01

    This presentation is a technical summary of and outlook for NASA-internal and NASA-sponsored external research on core (combustor and turbine) noise funded by the Fundamental Aeronautics Program Fixed Wing Project. The presentation covers: the emerging importance of core noise due to turbofan design trends and its relevance to the NASA N+3 noise-reduction goal; the core noise components and the rationale for the current emphasis on combustor noise; and the current and planned research activities in the combustor-noise area. Two NASA-sponsored research programs, with particular emphasis on indirect combustor noise, "Acoustic Database for Core Noise Sources", Honeywell Aerospace (NNC11TA40T) and "Measurement and Modeling of Entropic Noise Sources in a Single-Stage Low-Pressure Turbine", U. Illinois/U. Notre Dame (NNX11AI74A) are briefly described. Recent progress in the development of CMC-based acoustic liners for broadband noise reduction suitable for turbofan-core application is outlined. Combustor-design trends and the potential impacts on combustor acoustics are discussed. A NASA GRC developed nine-point lean-direct-injection (LDI) fuel injector is briefly described. The modification of an upcoming thermo-acoustic instability evaluation of the GRC injector in a combustor rig to also provide acoustic information relevant to community noise is presented. The NASA Fundamental Aeronautics Program has the principal objective of overcoming today's national challenges in air transportation. The reduction of aircraft noise is critical to enabling the anticipated large increase in future air traffic. The Quiet Performance Research Theme of the Fixed Wing Project aims to develop concepts and technologies to dramatically reduce the perceived community noise attributable to aircraft with minimal impact on weight and performance.

  8. Theoretical investigation of the neutron noise diagnostics of two-dimensional control rod vibrations in a PWR

    International Nuclear Information System (INIS)

    Pazsit, I.; Analytis, G.T.

    1980-01-01

    In order to develop a method for monitoring control rod vibrations by neutron noise measurements, the noise induced by two-dimensional vibrations of control elements is investigated. The two-dimensional Green's function relating the small stochastic cross-section fluctuations to the neutron noise is determined for a rectangular slab reactor in the modified one-group theory, and subsequently, the neutron response to two-dimensional vibrating noise sources is investigated. Two possible diagnostical applications are considered: (a) the reconstruction of the mechanical trajectory of the vibrating element by neutron noise measurements, and (b) the possibility of locating the vibrating element in the core. (author)

  9. Monitoring the mechanical vibration of in-core detector tubes and fuel channels via ICFD noise analysis

    International Nuclear Information System (INIS)

    Glockler, O.; Cooke, D.F.; Czuppon, G.J.; Kapoor, K.K.

    2000-01-01

    Vibrations of core internals are regularly monitored in the CANDU nuclear generating stations of Ontario Power Generation (OPG) via the noise analysis of in-core flux detectors (ICFDs). Voltage signals of standard station instrumentation are recorded by portable multi-channel high-speed high-resolution data acquisition systems, then statistical parameters are derived from the multi-channel time series measurements. Reactor noise analysis is a non-intrusive statistical technique regularly used in system surveillance, diagnostics and in actual operational I and C problems. It utilizes the dynamic information carried by the small fluctuations (noise) of station signals measured around their mean values during steady-state operation. The present paper discusses specific results related to the flow-induced mechanical vibrations of detector tubes and fuel channels. (author)

  10. Relationship of core exit-temperature noise to thermal-hydraulic conditions in PWRs

    International Nuclear Information System (INIS)

    Sweeney, F.J.; Upadhyaya, B.R.

    1983-01-01

    Core exit thermocouple temperature noise and neutron detector noise measurements were performed at the Loss of Fluid Test Facility (LOFT) reactor and a Westinghouse, 1148 MW(e) PWR to relate temperature noise to core thermal-hydraulic conditions. The noise analysis results show that the RMS of the temperature noise increases linearly with increasing core δT at LOFT and the commercial PWR. Out-of-core test loop temperature noise has shown similar behavior. The phase angle between core exit temperature noise and in-core or ex-core neutron noise is directly related to the core coolant flow velocity. However, if the thermocouple response time is slow, compared to the coolant transit time between the sensors, velocities inferred from the phase angle are lower than measured coolant flow velocities

  11. Core Noise Diagnostics of Turbofan Engine Noise Using Correlation and Coherence Functions

    Science.gov (United States)

    Miles, Jeffrey H.

    2009-01-01

    Cross-correlation and coherence functions are used to look for periodic acoustic components in turbofan engine combustor time histories, to investigate direct and indirect combustion noise source separation based on signal propagation time delays, and to provide information on combustor acoustics. Using the cross-correlation function, time delays were identified in all cases, clearly indicating the combustor is the source of the noise. In addition, unfiltered and low-pass filtered at 400 Hz signals had a cross-correlation time delay near 90 ms, while the low-pass filtered at less than 400 Hz signals had a cross-correlation time delay longer than 90 ms. Low-pass filtering at frequencies less than 400 Hz partially removes the direct combustion noise signals. The remainder includes the indirect combustion noise signal, which travels more slowly because of the dependence on the entropy convection velocity in the combustor. Source separation of direct and indirect combustion noise is demonstrated by proper use of low-pass filters with the cross-correlation function for a range of operating conditions. The results may lead to a better idea about the acoustics in the combustor and may help develop and validate improved reduced-order physics-based methods for predicting direct and indirect combustion noise.

  12. Some developments in core-barrel vibration diagnostics

    International Nuclear Information System (INIS)

    Pazsit, I.; Karlsson, J.; Garis, N.S.

    1998-01-01

    Diagnostics of core-barrel motion, and notably that of beam mode vibrations, has been usually performed by two distinct concepts. One strategy is to perform a qualitative analysis in the time domain, using descriptors such as vibration trajectory, probability distributions etc. This approach is rather realistic in the sense that it allows for general anisotropic pendular vibrations. The other strategy is to use frequency analysis with the goal of quantifying certain vibration properties. However, this second approach could so far handle only isotropic and unidirectional vibrations. In this paper we propose a unification of these two approaches by introducing a model by which general anisotropic vibrations can be quantified in the frequency domain. However, when separating the noise components prior to the frequency analysis, we suggest the use of symmetry properties of the noise in the time domain, based on reactor physics assumptions, as opposed to the earlier methods that use statistical independence of the components. Due to the unified approach, a combination of time and frequency domain analysis methods can be used for presentation and maximum information extraction

  13. Noise Diagnostics of Stationary and Non-Stationary Reactor Processes

    Energy Technology Data Exchange (ETDEWEB)

    Sunde, Carl

    2007-04-15

    This thesis concerns the application of noise diagnostics on different problems in the area of reactor physics involving both stationary and non-stationary core processes. Five different problems are treated, divided into three different parts. The first problem treated in the first part is the classification of two-phase flow regimes from neutron radiographic and visible light images with a neuro-wavelet algorithm. The algorithm consists of wavelet pre-processing and of an artificial neural network. The result indicates that the wavelet pre-processing is improving the training of the neural network. Next, detector tubes which are suspected of impacting on nearby fuel-assemblies in a boiling water reactor (BWR) are identified by both a classical spectral method and wavelet-based methods. It was found that there is good agreement between the different methods as well as with visual inspections of detector tube and fuel assembly damage made during the outage at the plant. The third problem addresses the determination of the decay ratio of a BWR from the auto-correlation function (ACF). Here wavelets are used, with some success, both for de-trending and de-nosing of the ACF and also for direct estimation of the decay ratio from the ACF. The second part deals with the analysis of beam-mode and shell-mode core-barrel vibrations in pressurised water reactors (PWRs). The beam-mode vibrations are analysed by using parameters of the vibration peaks, in spectra from ex core detectors. A trend analysis of the peak amplitude shows that the peak amplitude is changing during the fuel cycle. When it comes to the analysis of the shell-mode vibration, 1-D analytical and numerical calculations are performed in order to calculate the neutron noise induced in the core. The two calculations are in agreement and show that a large local noise component is present in the core which could be used to classify the shell-mode vibrations. However, a measurement made in the PWR Ringhals-3 shows

  14. Noise Diagnostics of Stationary and Non-Stationary Reactor Processes

    International Nuclear Information System (INIS)

    Sunde, Carl

    2007-01-01

    This thesis concerns the application of noise diagnostics on different problems in the area of reactor physics involving both stationary and non-stationary core processes. Five different problems are treated, divided into three different parts. The first problem treated in the first part is the classification of two-phase flow regimes from neutron radiographic and visible light images with a neuro-wavelet algorithm. The algorithm consists of wavelet pre-processing and of an artificial neural network. The result indicates that the wavelet pre-processing is improving the training of the neural network. Next, detector tubes which are suspected of impacting on nearby fuel-assemblies in a boiling water reactor (BWR) are identified by both a classical spectral method and wavelet-based methods. It was found that there is good agreement between the different methods as well as with visual inspections of detector tube and fuel assembly damage made during the outage at the plant. The third problem addresses the determination of the decay ratio of a BWR from the auto-correlation function (ACF). Here wavelets are used, with some success, both for de-trending and de-nosing of the ACF and also for direct estimation of the decay ratio from the ACF. The second part deals with the analysis of beam-mode and shell-mode core-barrel vibrations in pressurised water reactors (PWRs). The beam-mode vibrations are analysed by using parameters of the vibration peaks, in spectra from ex core detectors. A trend analysis of the peak amplitude shows that the peak amplitude is changing during the fuel cycle. When it comes to the analysis of the shell-mode vibration, 1-D analytical and numerical calculations are performed in order to calculate the neutron noise induced in the core. The two calculations are in agreement and show that a large local noise component is present in the core which could be used to classify the shell-mode vibrations. However, a measurement made in the PWR Ringhals-3 shows

  15. Systems for noise diagnostics of WWER nuclear power plants

    International Nuclear Information System (INIS)

    Por, G.

    1996-01-01

    The aim of this paper is to give a short overview of the noise diagnostics system developed by Hungarian firms which are in operation in WWER type NPP Units. Giving a list of systems developed for noise diagnostics of WWER reactors we present their main characteristics, their goal and some of their achievements. The second part deals with the problem of acceptance of noise system by NPP and regulations. (author). 24 refs

  16. Systems for noise diagnostics of WWER nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Por, G [Technical Univ. of Budapest, Budapest (Hungary)

    1997-12-31

    The aim of this paper is to give a short overview of the noise diagnostics system developed by Hungarian firms which are in operation in WWER type NPP Units. Giving a list of systems developed for noise diagnostics of WWER reactors we present their main characteristics, their goal and some of their achievements. The second part deals with the problem of acceptance of noise system by NPP and regulations. (author). 24 refs.

  17. Application of noise analysis methods in nuclear reactor diagnostics

    International Nuclear Information System (INIS)

    Dach, K.

    1985-01-01

    By statistical evaluation of the fluctuation component of signals from selected detectors, noise diagnostics detects conditions of equipment which might later result in failure. The objective of early diagnostics is to detect the failed integrity of primary circuit components, failed detectors or anomalies of the thermohydraulic process. The commonest method of experimental data analysis is spectral analysis in the frequency range 0 to 50 Hz. Recently, expert diagnostic systems have been built based on artificial intelligence systems. Czechoslovakia participates in the experimental research of noise diagnostics in the context of the development of diagnostic assemblies for WWER-440 reactors. (M.D.)

  18. Studies on neutron noise diagnostics of control rod vibrations by neural networks

    International Nuclear Information System (INIS)

    Roston, G.; Kozma, R.; Kitamura, M.; Garis, N.S.; Pazsit, I.

    1996-01-01

    This work is focussed on the study of a neutron noise based technique for the diagnostics of reactor core internal, in particular, excessively vibrating control rods. The use of a combination of physical models and neural networks offers an alternative way of performing the inversion procedure. The application of a neural network technique to determine the rod position from the detector spectra is much faster, more effective and simpler to use than the conventional method. (author). 5 refs., 1 fig., 1 tab

  19. Core component vibration monitoring in BWRs using neutron noise

    International Nuclear Information System (INIS)

    Fry, D.N.; Robinson, J.C.; Kryter, R.C.; Cole, O.C.

    1975-01-01

    Neutron noise from in-core fission detectors in a BWR was investigated to determine its effectiveness as a monitor of mechanical vibrations of core components. In this study the general properties of BWR neutron noise were characterized, and a signal enhancement method was implemented to improve the measurement sensitivity. (auth)

  20. Application of noise analysis to investigate core degradation process during PHEBUS-FPT1 test

    International Nuclear Information System (INIS)

    Oguma, Ritsuo

    1997-01-01

    Noise analysis has been performed for measurement data obtained during PHEBUS-FPT1 test. The purpose of the study is to evaluate the applicability of the noise analysis to the following problems: To get more knowledge about the physical processes going on during severe core conditions; To better understand the core melting process; To establish appropriate on-line shut-down data. Results of the study indicate that the noise analysis is quite promising as a tool for investigating physical processes during the experiment. Compared with conventional approach of evaluating the signal's mean value behaviour, the noise analysis can provide additional, more detailed information: It was found that the neutron flux signal is subjected to additional reactivity perturbations in conjunction with fuel melting and relocation. This can easily be detected by applying noise analysis for the neutron flux signal. It has been demonstrated that the method developed in the present study can provide more accurate estimates of the onset of fuel relocation than using temperature signals from thermocouples in the thermal shroud. Moreover, the result suggests a potential of the present method for tracking the whole process of relocation. The result of the data analysis suggests a possibility of sensor diagnostics which may be important for confirming the quality and reliability of the recorded data. Based on the results achieved it is believed that the combined use of noise analysis and thermocouple signals will provide reliable shut-down criteria for the experiment. 8 refs

  1. Noise variation by compressive stress on the model core of power transformers

    Energy Technology Data Exchange (ETDEWEB)

    Mizokami, Masato, E-mail: mizokami.g76.masato@jp.nssmc.com; Kurosaki, Yousuke

    2015-05-01

    The reduction of audible noise generated by cores for power transformers has been required due to environmental concern. It is known that compressive stress in the rolling direction of electrical steel affects magnetostriction and it can result in an increase in noise level. In this research, the effect of compressive stress to noise was investigated on a 3-phase 3-limb model core. Compressive stress was applied in the rolling direction of the limbs from the outside of the core. It increased the sound pressure levels and the slope of the rise was about 2 dBA/MPa. Magnetostriction on single sheet samples was also measured under compressive stress and the harmonic components of the magnetostriction were compared with those of noise. It revealed that the variation in magnetostriction with compressive stress did not entirely correspond to that in noise. In one of the experiments, localized bending happened on one limb during compressing the core. While deformation of the core had not been intended, the noise was measured. The deformation increased the noise by more than 10 dBA and it occurred on most of the harmonic components. - Highlights: • Audible noise was measured on a model core to which compressive stress was applied. • The stress in the rolling direction of the steel causes a rise in noise level. • The slope of the rise in sound pressure level up to 2.5 MPa is about 2 dBA/MPa. • Variation in magnetostriction by stress does not entirely agree with that in noise. • Bend arisen in the core causes an extreme increase in noise.

  2. Noise variation by compressive stress on the model core of power transformers

    International Nuclear Information System (INIS)

    Mizokami, Masato; Kurosaki, Yousuke

    2015-01-01

    The reduction of audible noise generated by cores for power transformers has been required due to environmental concern. It is known that compressive stress in the rolling direction of electrical steel affects magnetostriction and it can result in an increase in noise level. In this research, the effect of compressive stress to noise was investigated on a 3-phase 3-limb model core. Compressive stress was applied in the rolling direction of the limbs from the outside of the core. It increased the sound pressure levels and the slope of the rise was about 2 dBA/MPa. Magnetostriction on single sheet samples was also measured under compressive stress and the harmonic components of the magnetostriction were compared with those of noise. It revealed that the variation in magnetostriction with compressive stress did not entirely correspond to that in noise. In one of the experiments, localized bending happened on one limb during compressing the core. While deformation of the core had not been intended, the noise was measured. The deformation increased the noise by more than 10 dBA and it occurred on most of the harmonic components. - Highlights: • Audible noise was measured on a model core to which compressive stress was applied. • The stress in the rolling direction of the steel causes a rise in noise level. • The slope of the rise in sound pressure level up to 2.5 MPa is about 2 dBA/MPa. • Variation in magnetostriction by stress does not entirely agree with that in noise. • Bend arisen in the core causes an extreme increase in noise

  3. Monitoring core barrel motion by neutron noise diagnostics

    International Nuclear Information System (INIS)

    Por, G.

    1985-08-01

    The core barrel motion is detected by ionization chambers located around the reactor vessel. The method is based on the measurement of the neutron flux fluctuations. Calculations to determine the direction and the size of the motion are discussed. The identification of core barrel motion and its connection with the error of one of the main circulating pumps in the Rheinsberg nuclear power plant are described. Core barrel motion of 10 Hz with an amplitude less than 50 μm could be diagnozed at the Paks-1 reactor using the Dutch high accuracy evaluation system. (V.N.)

  4. Applications of a surveillance and diagnostics methodology using neutron noise from a pressurized-water reactor

    International Nuclear Information System (INIS)

    Wood, R.T.; Miller, L.F.; Perez, R.B.

    1992-01-01

    Two applications of a noise diagnostic methodology were performed with ex-core neutron detector data from a pressurized-water reactor (PWR). A feedback dynamics model of the neutron power spectral denisty was derived from a low-order whole-plant physical model made stochastic with the Langevin technique. From a functional fit to plant data, the response of the dynamic system to changes in important physical parameters was evaluated by a direct sensitivity analysis. In addition, changes in monitored spectra were related to changes in physical parameters, and detection thresholds using common surveillance discriminants were determined. A resonance model was developed from perturbation theory to give the ex-core neutron detector response for small in-core mechanical motions in terms of a pole-strength factor, a resonance asymmetry (or skewness) factor, a vibration damping factor, and a frequency of vibration. The mechanical motion paramters for several resonances were determined by a functional fit of the model to plant data taken at various times during a fuel cycle and were tracked to determined trends that indicated vibrational changes of reactor internals. In addition, the resonance model gave the ability to separate the resonant components of the power spectral density after the parameters had been identified. As a result, the behavior of several vibration peaks was monitored over a fuel cycle. The noise diagnostic methodology illustrated by these applications can be used in monitoring the condition of the reactor system. Early detection of degraded mechanical components or undesirable operating conditions by using such surveillance and diagnostic techniques would enhance plant safety. 15 refs., 6 figs., 1 tab

  5. Investigations of certain problems in reactor noise diagnostics

    International Nuclear Information System (INIS)

    Karlsson, Joakim.

    1997-06-01

    A number of problems in reactor noise diagnostics have been investigated within the framework of the present thesis. The papers presented cover three relatively different areas, namely neutron noise induced by small vibrations of a strong absorber, the decomposition of noise in BWRs with application to stability monitoring, and fluctuation analysis of soft x-ray signals from fusion plasmas. 18 refs, 6 figs

  6. Investigations of certain problems in reactor noise diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Karlsson, Joakim

    1997-06-01

    A number of problems in reactor noise diagnostics have been investigated within the framework of the present thesis. The papers presented cover three relatively different areas, namely neutron noise induced by small vibrations of a strong absorber, the decomposition of noise in BWRs with application to stability monitoring, and fluctuation analysis of soft x-ray signals from fusion plasmas. 18 refs, 6 figs.

  7. Model-based temperature noise monitoring methods for LMFBR core anomaly detection

    International Nuclear Information System (INIS)

    Tamaoki, Tetsuo; Sonoda, Yukio; Sato, Masuo; Takahashi, Ryoichi.

    1994-01-01

    Temperature noise, measured by thermocouples mounted at each core fuel subassembly, is considered to be the most useful signal for detecting and locating local cooling anomalies in an LMFBR core. However, the core outlet temperature noise contains background noise due to fluctuations in the operating parameters including reactor power. It is therefore necessary to reduce this background noise for highly sensitive anomaly detection by subtracting predictable components from the measured signal. In the present study, both a physical model and an autoregressive model were applied to noise data measured in the experimental fast reactor JOYO. The results indicate that the autoregressive model has a higher precision than the physical model in background noise prediction. Based on these results, an 'autoregressive model modification method' is proposed, in which a temporary autoregressive model is generated by interpolation or extrapolation of reference models identified under a small number of different operating conditions. The generated autoregressive model has shown sufficient precision over a wide range of reactor power in applications to artificial noise data produced by an LMFBR noise simulator even when the coolant flow rate was changed to keep a constant power-to-flow ratio. (author)

  8. Research and Development Program in Reactor Diagnostics and Monitoring with Neutron Noise Methods, Stage 18

    International Nuclear Information System (INIS)

    Pazsit, Imre; Nam, Tran Hoai; Dykin, Victor; Jonsson, Anders

    2013-01-01

    This report constitutes Stage 18 of a long-term research and development program concerning the development of diagnostics and monitoring methods for nuclear reactors. The objective of the research program is to contribute to the strategic research goal of competence and research capacity by building up competence within the Department of Nuclear Engineering at Chalmers University of Technology, regarding reactor physics, reactor dynamics and noise diagnostics. The purpose is also to contribute to the research goal of giving a basis for SSM's supervision by developing methods for identification and localization of perturbations in reactor cores. Results up to Stage 17 were reported in SKI and SSM reports, as listed in the report's summary

  9. Temperature noise characteristics of pressurized water reactors

    International Nuclear Information System (INIS)

    Sweeney, F.J.; Upadhyaya, B.R.

    1984-01-01

    The core exit temperature noise RMS is linearly related to the core ΔT at a commercial PWR and LOFT. Test loop observations indicate that this linear behavior becomes nonlinear with blockages, boiling, or power skews. The linear neutron flux to temperature noise phase behavior is indicative of a pure time delay process, which has been shown to be related to coolant flow velocity in the core. Therefore, temperature noise could provide a valuable diagnostic tool for the detection of coolant blockages, boiling, and sensor malfunction under both normal and accident conditions in a PWR

  10. Calculation of the ex-core neutron noise induced by fuel vibrations in PWRs

    International Nuclear Information System (INIS)

    Tran Hoai Nam; Cao Van Chung; Hoang Thanh Phi Hung; Hoang Van Khanh

    2015-01-01

    Calculation of the neutron noise induced by fuel assembly vibrations in two pressurized water reactor (PWR) cores has been performed to investigate the effect of cycle burnup on the properties of the ex-core detector noise. Pendular vibrations of individual fuel assemblies were assumed to occur at different locations in the core. The auto power spectra density (APSD) of the ex-core detector noise was evaluated with the assumption of stochastic vibrations along a random two-dimensional trajectory. The results show that no general monotonic variation of APSD was found. The increase of APSD occurs predominantly for peripheral assemblies. Assuming simultaneous vibrations of a number of fuel assemblies uniformly distributed over the core with the more realistic perturbation model, the effect of the peripheral assemblies will dominate and the increase of the amplitude of the ex-core neutron noise with burnup can be confirmed. (author)

  11. Developments and application of neutron noise diagnostics of sodium cooled fast reactors

    International Nuclear Information System (INIS)

    Zylbersztejn, F.

    2013-01-01

    The Sodium cooled Fast Reactor (SFR) is one of the six reactor types selected by the Generation-IV international forum (GIF), and the building of an industrial prototype is planned in France. The safety standard of the future SFR has to be equivalent to the EPR's. The general improvement of the safety of the new reactor goes through the examination of all the potentially harmful scenarios and both the study and monitoring of early signs. The mechanical deformations of the core can have harmful consequences in sodium fast reactors, such as unexpected power variations due to the reactivity increase in case of core compaction, or the excessive deterioration of the mechanical structures. The monitoring of such phenomena and of their potential early signs is then needed. The monitoring of such phenomena can be done with neutron detectors placed inside and outside the tank. This PhD thesis deals with the study of the neutron noise generated by the periodic deformation of the SFR core, restricted to the so-called core compaction or core flowering phenomenon, a deformation consisting in the variation of the inter-assembly sodium width by a radial bending the assemblies (the assemblies in SFR are held by the base). The PhD thesis has been performed within collaboration between CEA (France) and Chalmers Institute of Technology (Sweden). The work realized during the thesis led to the publication of 3 articles as first author and another as second author. This work has embraced the following topics: A state of the art of the monitoring of the core deformation phenomenon by interpretation of the noise measurements in SFR has been done. The PHENIX reactor multi physics measurements database has been scrutinized to provide an interpretation of the neutron noise bringing out mechanical vibration phenomena. An important conclusion was that the lack of theoretical knowledge about the neutron noise induced by the vibration phenomenon and the ill positioning of the neutron detectors

  12. Gear noise, vibration, and diagnostic studies at NASA Lewis Research Center

    Science.gov (United States)

    Zakrajsek, J. J.; Oswald, F. B.; Townsend, D. P.; Coy, J. J.

    1990-01-01

    The NASA Lewis Research Center and the U.S. Army Aviation Systems Command are involved in a joint research program to advance the technology of rotorcraft transmissions. This program consists of analytical as well as experimental efforts to achieve the overall goals of reducing weight, noise, and vibration, while increasing life and reliability. Recent analytical activities are highlighted in the areas of gear noise, vibration, and diagnostics performed in-house and through NASA and U.S. Army sponsored grants and contracts. These activities include studies of gear tooth profiles to reduce transmission error and vibration as well as gear housing and rotordynamic modeling to reduce structural vibration and transmission and noise radiation, and basic research into current gear failure diagnostic methodologies. Results of these activities are presented along with an overview of near-term research plans in the gear noise, vibration, and diagnostics area.

  13. Base neutron noise in PWRs

    International Nuclear Information System (INIS)

    Kosaly, G.; Albrecht, R.W.; Dailey, D.J.; Fry, D.N.

    1981-01-01

    Considerable activity has been devoted in recent years to the use of neutron noise for investigation of problems in pressurized-water reactors (PWRs). The investigators have found that neutron noise provides an effective way to monitor reactor internal vibrations such as vertical and lateral core motion; core support barrel and thermal shield shell modes, bending modes of fuel assemblies, and control rod vibrations. However, noise analysts have also concluded that diagnosis of a problem is easier if baseline data for normal plant operation is available. Therefore, the authors have obtained ex-core neutron noise signatures from eight PWRs to determine the similarity of signatures between plants and to build a base of data to determine the sources of neutron noise and thus the potential diagnostic information contained in the data. It is concluded that: (1) ex-core neutron noise contains information about the vibration of components in the pressure vessel; (2) baseline signature acquisition can aid understanding of plant specific vibration frequencies and provide a bases for diagnosis of future problems if they occur; and (3) abnormal core support barrel vibration can most likely be detected over and above the plant-to-plant signature variation observed thus far

  14. Applications of digital processing for noise removal from plasma diagnostics

    International Nuclear Information System (INIS)

    Kane, R.J.; Candy, J.V.; Casper, T.A.

    1985-01-01

    The use of digital signal techniques for removal of noise components present in plasma diagnostic signals is discussed, particularly with reference to diamagnetic loop signals. These signals contain noise due to power supply ripple in addition to plasma characteristics. The application of noise canceling techniques, such as adaptive noise canceling and model-based estimation, will be discussed. The use of computer codes such as SIG is described. 19 refs., 5 figs

  15. A study on the fault diagnostic techniques for reactor internal structures using neutron noise analysis

    International Nuclear Information System (INIS)

    Kim, Tae Ryong; Jeong, Seong Ho; Park, Jin Ho; Park, Jin Suk

    1994-08-01

    The unfavorable phenomena, such as flow induced vibration and aging process in reactor internals, cause degradation of structural integrity and may result in loosing some mechanical binding components which might impact other equipments and components or cause flow blockage. Since these malfunctions and potential failures change reactor noise signal, it is necessary to analyze reactor noise signal for early fault diagnosis in the point of few of safety and plant economics. The objectives of this study are to establish fault diagnostic and TS(thermal shield), and to develop a data acquisition and signal processing software system. In the first year of this study, an analysis technique for the reactor internal vibration using the reactor noise was proposed. With the technique proposed and the reactor noise signals (ex-core neutron and acceleration), the dynamic characteristics of Ulchin-1 reactor internals were obtained, and compared with those of Tricastin-1 which is the prototype of Ulchin-1. In the second year, a PC-based expert system for reactor internals fault diagnosis is developed, which included data acquisition, signal processing, feature extraction function, and represented diagnostic knowledge by the IF-THEN rule. To know the effect of the faults, the reactor internals of Ulchin-1 is modeled using FEM and simulated with an artificial defect given in the hold-down spring. Trend in the dynamic characteristics of reactor internals is also observed during one fuel cycle to know the effect of boron concentration. 100 figs, 7 tabs, 18 refs. (Author)

  16. Influence of fuel vibration on PWR neutron noise associated with core barrel motion

    International Nuclear Information System (INIS)

    Sweeney, F.J.; March-Leuba, J.

    1984-01-01

    Ex-core neutron detector noise has been utilized to monitor core support barrel (CSB) vibrations. In order to observe long-term changes, noise signals at Sequoyah-1 were monitored continuously during the whole first fuel cycle and part of the second cycle. Results suggest that neutron noise measurements performed infrequently may not provide adequate surveillance of the CSB because it may be difficult to separate noise amplitude changes due solely to CSB motion from changes caused by fuel motion and burnup

  17. Spatial Correlation in the Ambient Core Noise Field of a Turbofan Engine

    Science.gov (United States)

    Miles, Jeffrey Hilton

    2012-01-01

    An acoustic transfer function relating combustion noise and turbine exit noise in the presence of enclosed ambient core noise is investigated using a dynamic system model and an acoustic system model for the particular turbofan engine studied and for a range of operating conditions. Measurements of cross-spectra magnitude and phase between the combustor and turbine exit and auto-spectra at the turbine exit and combustor are used to show the presence of indirect and direct combustion noise over the frequency range of 0 400 Hz. The procedure used evaluates the ratio of direct to indirect combustion noise. The procedure used also evaluates the post-combustion residence time in the combustor which is a factor in the formation of thermal NOx and soot in this region. These measurements are masked by the ambient core noise sound field in this frequency range which is observable since the transducers are situated within an acoustic wavelength of one another. An ambient core noise field model based on one and two dimensional spatial correlation functions is used to replicate the spatially correlated response of the pair of transducers. The spatial correlation function increases measured attenuation due to destructive interference and masks the true attenuation of the turbine.

  18. Calculation of the neutron noise induced by periodic deformations of a large sodium-cooled fast reactor core

    International Nuclear Information System (INIS)

    Zylbersztejn, F.; Tran, H.N.; Pazsit, I.; Filliatre, P.; Jammes, C.

    2014-01-01

    The subject of this paper is the calculation of the neutron noise induced by small-amplitude stationary radial variations of the core size (core expansion/compaction, also called core flowering) of a large sodium-cooled fast reactor. The calculations were performed on a realistic model of the European Sodium Fast Reactor (ESFR) core with a thermal output of 3600 MW(thermal), using a multigroup neutron noise simulator. The multigroup cross sections and their fluctuations that represent the core geometry changes for the neutron noise calculations were generated by the code ERANOS. The space and energy dependences of the noise source represented by the core expansion/compaction and the induced neutron noise are calculated and discussed. (authors)

  19. Reactor internals vibration monitoring by neutron noise methods in PWRs

    International Nuclear Information System (INIS)

    Pazsit, I.; Por, G.; Lux, I.

    1983-01-01

    Certain elements of PWR cores such as control/fuel rods or cassettes, or other parts of reactor internals, often represent a vibration problem. Early analyses at operating PWR plant revealed that these vibrations can be detected by in-core neutron detectors, opening up the possibility of vibration monitoring and diagnostics by noise methods. Theoretical methods of calculating vibration induced neutron noise and its application to vibration diagnostics are summarized. Experiments to check theoretical conclusions are under way at the Central Research Institute for Physics, Budapest. (author)

  20. Upgrading the reactor noise diagnostic systems at the Paks NPP

    International Nuclear Information System (INIS)

    Czibok, T.; Dezsoe, Z.; Kiss, K.; Krinizs, K.; Lipcsei, S.

    2002-01-01

    The paper reports on the actual step in upgrading process of the reactor noise diagnostic systems at Paks NPP. This step has mainly a technical character. Renewal of facilities for signal conditioning and for data acquisition is going on. Autonomous systems at each of the four reactor units will be able to acquire a set of data series which can be arbitrarily chosen from the whole set of several hundred in-core neutron and other signals. The autonomous systems can be remotely controlled by a central computer through the local network. Modularity and extensibility are important features of the new systems: the size of the set of available signals can be extended and new modules for more advanced evaluations can be installed later. Present plans for system hardware upgrading are outlined, together with some technical details of measurement control, data acquisition moduls and network communication.(abstract)

  1. Application of neural networks and neutron noise for diagnostics of reactor internals vibration

    International Nuclear Information System (INIS)

    Garis, N.S.; Pazsit, I.; Gloeckler, O.

    1995-01-01

    It has long been known that vibration of reactor internals, in particular excessive vibrations of control rods, can be detected via the neutron noise they induce. Noise measurements are actually suitable to determine important diagnostic parameters such as the location of the vibrating rod and the vibration amplitude. An algorithm was earlier elaborated for this purpose, which is based on inversion of the expression describing the neutron noise as a function of vibration parameters. This inversion procedure is nevertheless complicated and not always unique. It was investigated whether a properly trained neural network can perform the inversion more effectively. It was found that artificial neural networks can be trained effectively to perform vibration diagnostics from neutron noise data fast, effectively and reliably. The present paper gives a description of the development and use of the neural networks for purposes of vibration diagnostics

  2. Research program in reactor core diagnostics with neutron noise methods: Stage 3. Final report; Forskningsprogram angaaende haerddiagnostik med neutronbrusmetoder. Etapp 3. Slutrapport

    Energy Technology Data Exchange (ETDEWEB)

    Pazsit, I.; Garis, N.S.; Karlsson, J.; Racz, A. [Chalmers Univ. of Technology, Goeteborg (Sweden). Dept. of Reactor Physics

    1997-09-01

    Stage 3 of the program has been executed 96-04-12. The long term goal is to develop noise methods for identification and localization of perturbations in reactor cores. The main parts of the program consist of modelling the noise source, calculation of the space- and frequency dependent transfer function, calculation of the neutron noise via a convolution of the transfer function of the system and the noise source, i.e. the perturbation, and finally finding an inversion or unfolding procedure to determine noise source parameters from the neutron noise. Most previous work is based on very simple (analytical) reactor models for the calculation of the transfer function as well as analytical unfolding methods. The purpose of this project is to calculate the transfer function in a more realistic model as well as elaborating powerful inversion methods that do not require analytical transfer functions. The work in stage 3 is described under the following headlines: Further investigation of simplified models for the calculation of the neutron noise; Further investigation of methods based on neural networks; Further investigation of methods for detecting the vibrations and impacting of detectors; Application of static codes for determination of the neutron noise using the adiabatic approximation. 12 refs, 18 figs.

  3. Vibration and noise diagnostics of nuclear power plants Pt. 1

    International Nuclear Information System (INIS)

    Nagy, I.

    1991-01-01

    Development, tasks and methodology of vibration and noise testing of nuclear power plants are overviewed. Reactor noise diagnostics methods are presented and their utilization at various reactors is summarized. Acoustic testing of primary circuit is also considered. Special attention is paid to leak detection and loose parts monitoring by acoustical testing methods. (R.P.) 11 refs.; 18 figs.; 1 tab

  4. Identifying functions for ex-core neutron noise analysis

    International Nuclear Information System (INIS)

    Avila, J.M.; Oliveira, J.C.

    1987-01-01

    A method of performing the phase analysis of signals arising from neutron detectors placed in the periphery of a pressurized water reactor is proposed. It consists in the definition of several identifying functions, based on the phases of cross power spectral densities corresponding to four ex-core neutron detectors. Each of these functions enhances the appearance of different sources of noise. The method, applied to the ex-core neutron fluctuation analysis of a French PWR, proved to be very useful as it allows quick recognition of various patterns in the power spectral densities. (orig.) [de

  5. The role of neural networks in reactor diagnostics and control

    International Nuclear Information System (INIS)

    Pazsit, I.; Kitamura, M.

    1997-01-01

    Reactor diagnostics and core diagnostics in particular, is an inverse task, just as most other diagnostics. One measures some physical parameter at some position, or the fluctuation thereof, which is given rise by the fluctuation of another parameter, presumably at a different position. In neutron noise diagnostics, the measured quantity is the neutron noise, whereas the cause, fluctuations of the core material, is called the open-quotes noise sourceclose quotes. The relationship between the cause (noise source) and the induced noise (effect) is determined by the physics of the process and can usually be described by a theory. This means that the direct task, calculation of the noise from the noise source, can always be achieved. In diagnostics, however, the process starts from the back end, i.e. one observes the effect of some cause. The task is to infer the cause (noise source) from the effect (induced noise), which is an inverse task (sometimes also called unfolding). The situation is very much similar even regarding control problems. The system state is described by a vector in the parameter space. When it deviates from the desired one, the control parameters need to be changed to bring the system into the desired state. The computation of the change in the state vector, due to a change in the control vector, can be calculated with no difficulty in principle. The control requires however the inverse task to be performed, i.e. to determine which changes of the control vector would bring the state vector into the desired state

  6. On the neutron noise diagnostics of pressurized water reactor control rod vibrations. 1. periodic vibrations

    International Nuclear Information System (INIS)

    Pazsit, I.; Glockler, O.

    1983-01-01

    Based on the theory of neutron noise arising from the vibration of a localized absorber, the possibility of rod vibration diagnostics is investigated. It is found that noise source characteristics, namely rod position and vibration trajectory and spectra, can be unfolded from measured neutron noise signals. For the localization process, the first and more difficult part of the diagnostics, a procedure is suggested whose novelty is that it is applicable in case of arbitrary vibration trajectories. Applicability of the method is investigated in numerical experiments where effects of background noise are also accounted for

  7. First evaluation of low frequency noise measurements of in core detector signals in the measuring assembly Rheinsberg

    International Nuclear Information System (INIS)

    Collatz, S.

    1982-01-01

    Reactor noise spectra of in core neutron detectors are measured in the low frequency range (0.03 Hz to 1 Hz) and evaluated. The increase of the effective noise signal value is due to pressure oscillations or oscillations of special steam volume portions. Thus boiling monitoring of reactor cores in PWR type reactors may be possible, if the low frequency noise of the whole set of in core detectors is taken into account

  8. Discrimination of ex-core neutron noise signatures using artificial neural networks

    International Nuclear Information System (INIS)

    Alguindigue, I.E.; Uhrig, R.E.; Cai, M.; Trenty, A.

    1993-01-01

    The vibratory behavior of the internals in a Pressurized Water Reactor, PWR, can be identified and monitored using ex-core neutron noise data from power detectors located at ionization chambers outside the vessel. The signatures collected from these sensors provide information regarding presence of contacts between the core barrel and the pressure vessel, and more importantly, a means of verifying the integrity of components in the system. This report describes a neural-network-based methodology for identifying the vibration mode of the core barrel, and for detecting a particular family of mechanical failures. Features are extracted from the neutron noise spectra and used for training neural network models to identify the different states of vibratory behavior typically exhibited by PWR'S. The technique was tested on data from twenty eight 900MW pressurized water reactors in France, and the results achieved are over 98% accurate

  9. The Role of Flow Diagnostic Techniques in Fan and Open Rotor Noise Modeling

    Science.gov (United States)

    Envia, Edmane

    2016-01-01

    A principal source of turbomachinery noise is the interaction of the rotating and stationary blade rows with the perturbations in the airstream through the engine. As such, a lot of research has been devoted to the study of the turbomachinery noise generation mechanisms. This is particularly true of fan and open rotors, both of which are the major contributors to the overall noise output of modern aircraft engines. Much of the research in fan and open rotor noise has been focused on developing theoretical models for predicting their noise characteristics. These models, which run the gamut from the semi-empirical to fully computational ones, are, in one form or another, informed by the description of the unsteady flow-field in which the propulsors (i.e., the fan and open rotors) operate. Not surprisingly, the fidelity of the theoretical models is dependent, to a large extent, on capturing the nuances of the unsteady flowfield that have a direct role in the noise generation process. As such, flow diagnostic techniques have proven to be indispensible in identifying the shortcoming of theoretical models and in helping to improve them. This presentation will provide a few examples of the role of flow diagnostic techniques in assessing the fidelity and robustness of the fan and open rotor noise prediction models.

  10. BWR core response to fluctuations in coolant flow and pressure, with implications on noise diagnosis and stability monitoring

    International Nuclear Information System (INIS)

    Blomstrand, J.H.; Andersson, S.A.

    1982-01-01

    Reactor dynamic tests, utilizing sinuosidal oscillations in pressure and recirculation flow, have been conducted in operating BWRs in Sweden and Finland. Test data recorded, as well as recordings of process noise, have been analyzed in terms of dynamic core properties. The results obtained show good qualitative agreement with model predictions of BWR core dynamics. Model studies can often support interpretation of dynamic information obtained from operating plants. Comparisons between model studies, dynamic tests and process noise may also provide improved understanding of test results and noise patterns; in this way it can be demonstrated that some neutron flux noise is caused by noise in coolant flow and steam flow. From reactor test data nd noise recordings, core stability parameters have been evaluated by a number of methods. These have been found to provide essentially the same results. The cores investigated were found to be very stable under normal operating conditions. In special operating points, outside the normal operating range, higher decay ratios may occur. The experience indicates that for BWR cores, operated at decay ratios above quarter damping, the stability parameters may be identified from the oscillatory behavior of the autocorrelation in the time domain of the neutron flux noise

  11. Localization of Vibrating Noise Sources in Nuclear Reactor Cores

    International Nuclear Information System (INIS)

    Hultqvist, Pontus

    2004-09-01

    In this thesis the possibility of locating vibrating noise sources in a nuclear reactor core from the neutron noise has been investigated using different localization methods. The influence of the vibrating noise source has been considered to be a small perturbation of the neutron flux inside the reactor. Linear perturbation theory has been used to construct the theoretical framework upon which the localization methods are based. Two different cases have been considered: one where a one-dimensional one-group model has been used and another where a two-dimensional two-energy group noise simulator has been used. In the first case only one localization method is able to determine the position with good accuracy. This localization method is based on finding roots of an equation and is sensitive to other perturbations of the neutron flux. It will therefore work better with the assistance of approximative methods that reconstruct the noise source to determine if the results are reliable or not. In the two-dimensional case the results are more promising. There are several different localization techniques that reproduce both the vibrating noise source position and the direction of vibration with enough precision. The approximate methods that reconstruct the noise source are substantially better and are able to support the root finding method in a more constructive way. By combining the methods, the results will be more reliable

  12. Noise analysis of Forsmark 1 data to investigate BWR core local instability

    International Nuclear Information System (INIS)

    Oguma, R.

    1998-04-01

    BWR core local instability was experienced at Forsmark 1 (F1) during reactor operation in cycle 16. The event has been studied by applying noise analysis and stability calculations to get insight into the event as well as to identify the cause of local instability. The present report is concerned with noise analysis of data collected during start-up in cycle 17. The results of the current study indicates: The F1 core is quite stable in cycle 17. The max. decay ratio (DR) value of 0.37 was obtained from the stability evaluation of an APRM (average power range monitor) and LPRM (local power range monitor) signals measured at 66% (APRM) of reactor power and 4252 Kg/s (SA-HC) of core flow. Compared with the power profile in cycle 17 (as well as in reactor F2), the core in cycle 16 had an extreme power profile with high power and bottom-shifted axial peak in the core periphery esp. at the four quadrant corners. Such a profile decreases the stability margin in the region. It is a common observation that the DR obtained from APRM tends to be higher than that from LPRM if the global instability mechanism is dominant in the core, and vice versa. The comparison of global and local DR values should be an effective method for detecting local instability during the reactor operation. In order to detect the local instability it is important to evaluate the core stability with sufficient number of LPRMs so as to cover the whole core cross section together with APRMs

  13. Modeling of Thermal Phase Noise in a Solid Core Photonic Crystal Fiber-Optic Gyroscope.

    Science.gov (United States)

    Song, Ningfang; Ma, Kun; Jin, Jing; Teng, Fei; Cai, Wei

    2017-10-26

    A theoretical model of the thermal phase noise in a square-wave modulated solid core photonic crystal fiber-optic gyroscope has been established, and then verified by measurements. The results demonstrate a good agreement between theory and experiment. The contribution of the thermal phase noise to the random walk coefficient of the gyroscope is derived. A fiber coil with 2.8 km length is used in the experimental solid core photonic crystal fiber-optic gyroscope, showing a random walk coefficient of 9.25 × 10 -5 deg/√h.

  14. Application of noise analysis for the study of core local instability at Forsmark 1

    International Nuclear Information System (INIS)

    Oguma, Ritsuo

    1997-10-01

    Core local instability was recently experienced at Forsmark 1 BWR. The event has been studied by applying noise analysis to data collected in January 1997 for the stability test. The result indicated that there was a region in the left corner of the core which was subject to instability due to neutronic and thermal-hydraulic coupling. The result of the noise analysis suggested two types of disturbance source, one in the vicinity of the detector string LPRM10 having resonant oscillation at 0.5 Hz and another relatively wide band noise in the neighbourhood of LPRM18. Three hypotheses have been examined as the possible cause, operational factor, abnormal fuel assembly, and wide band low frequency disturbance. Although the real cause has not been made clear from the noise analysis, it is likely that the operational factor played an important role as the cause. Further investigations are expected to be performed in the future. In order to detect the local instability it is important to have a stability monitor with a capability of monitoring a sufficient number of LPRMs so as to cover the whole core. This is important since local instability is a type of anomaly which should not occur during reactor operation

  15. Advances in noise analysis for nuclear plant surveillance and diagnostics

    International Nuclear Information System (INIS)

    Fry, N.; Clapp, N.E. Jr.; Sides, W.H. Jr.; Mihalczo, J.T.; King, W.T.

    1980-01-01

    An automated surveillance and baseline noise signature acquisition system is being demonstrated at Sequoyah-1. A nonperturbing method is also being developed for monitoring the subcritical reactivity during initial core loading in LWRs, in fuel storage and processing facilities, and during postaccident recovery operations such as Three Mile Island-2

  16. Physics measurements on WWER-440 diagnostic assemblies

    International Nuclear Information System (INIS)

    Dach, K.; Jirousek, V.; Kott, J.; Horak, J.; Teren, S.; Nemec, J.

    1980-01-01

    The aims of physics measurements using diagnostic assemblies are the development of neutron noise diagnostics methods, the improvement of knowledge of the physical properties of the WWER reactor cores, the testing of computer programs, and the specification of nuclear safety criteria and the obtaining of information allowing the optimum nuclear fuel economy. The instrumentation of diagnostic assemblies is briefly described, including miniature fission chambers, SPN detectors and calorimeters. The method of evaluating and experimental testing is shown. (M.S.)

  17. 'Kazmer' a complex noise diagnostic system for 1000 MWe PWR WWER type nuclear power units

    International Nuclear Information System (INIS)

    Por, G.

    1992-06-01

    Noise diagnostic systems have previously been developed and installed for the WWER-440 type reactors at the Paks Nuclear Power Plant, Hungary. Based on the experiences, the system has been extended and modified for use in 1000 MWe, WWER-1000 type units. KAZMER consists of three subsystem, the KARD reactor noise diagnostic system, ARGUS vibration monitoring system for rotation machinery, and ALMOS acoustic monitoring system. The installation of the KAZMER system at the Kalinin Nuclear Power Station, Russia, and the first operational experiences are outlined. (R.P.) 15 refs.; 9 figs

  18. Determining the Optimal Number of Core Needle Biopsy Passes for Molecular Diagnostics.

    Science.gov (United States)

    Hoang, Nam S; Ge, Benjamin H; Pan, Lorraine Y; Ozawa, Michael G; Kong, Christina S; Louie, John D; Shah, Rajesh P

    2018-03-01

    The number of core biopsy passes required for adequate next-generation sequencing is impacted by needle cut, needle gauge, and the type of tissue involved. This study evaluates diagnostic adequacy of core needle lung biopsies based on number of passes and provides guidelines for other tissues based on simulated biopsies in ex vivo porcine organ tissues. The rate of diagnostic adequacy for pathology and molecular testing from lung biopsy procedures was measured for eight operators pre-implementation (September 2012-October 2013) and post-implementation (December 2013-April 2014) of a standard protocol using 20-gauge side-cut needles for ten core biopsy passes at a single academic hospital. Biopsy pass volume was then estimated in ex vivo porcine muscle, liver, and kidney using side-cut devices at 16, 18, and 20 gauge and end-cut devices at 16 and 18 gauge to estimate minimum number of passes required for adequate molecular testing. Molecular diagnostic adequacy increased from 69% (pre-implementation period) to 92% (post-implementation period) (p < 0.001) for lung biopsies. In porcine models, both 16-gauge end-cut and side-cut devices require one pass to reach the validated volume threshold to ensure 99% adequacy for molecular characterization, while 18- and 20-gauge devices require 2-5 passes depending on needle cut and tissue type. Use of 20-gauge side-cut core biopsy needles requires a significant number of passes to ensure diagnostic adequacy for molecular testing across all tissue types. To ensure diagnostic adequacy for molecular testing, 16- and 18-gauge needles require markedly fewer passes.

  19. Subassembly faults diagnostic of an LMFBR type reactor by the measurement of temperature noise

    International Nuclear Information System (INIS)

    Kokorev, B.V.; Palkin, I.I.; Turchin, N.M.; Pallagi, D.; Horanyi, S.

    1979-09-01

    The subassembly faults detection possibility by temperature noise analysis of an LMFBR is described. The paper contains the results of diagnostical examinations obtained on electrically heated NaK test rigs. On the basis of these results the measurement of temperature noise RMS value seems to be a practicable method to detect local blockages in an early phase. (author)

  20. Modeling and analysis of neutron noise from an ex-core detector at a pressurized water reactor

    International Nuclear Information System (INIS)

    Wood, R.T.; Perez, R.B.

    1991-01-01

    Two applications of a noise diagnostic methodology were performed using ex-core neutron detector data from a pressurized water reactor (PWR). A feedback dynamics model of the neutron power spectral density (PSD) was derived from a low-order whole-plant physical model made stochastic using the Langevin technique. From a functional fit to plant data, the response of the dynamic system to changes in important physical parameters was evaluated by a direct sensitivity analysis. In addition, changes in monitored spectra were related to changes in physical parameters and detection thresholds using common surveillance discriminants were determined. A resonance model was developed from perturbation theory to give the ex-core neutron detector response for small in-core mechanical motions in terms of a pole-strength factor, a resonance asymmetry (or skewness) factor, a vibration damping factor, and a frequency of vibration. The mechanical motion parameters for several resonances were determined by a functional fit of the model to plant data taken at various times during a fuel cycle and were tracked to determine trends that indicated vibrational changes of reactor internals. In addition, the resonance model gave the ability to separate the resonant components of the PSD after the parameters had been identified. As a result, the behavior of several vibration peaks were monitored over a fuel cycle. 9 refs., 6 figs., 1 tab

  1. Measurement of two-phase flow variables in a BWR by analysis of in-core neutron detector noise signals

    International Nuclear Information System (INIS)

    Stekelenburg, A.J.C.; Hagen, T.H.J.J. van der

    1996-01-01

    In this paper, the state of the art of the measurement of two-phase flow variables in a boiling water reactor (BWR) by analysis of in-core neutron detector noise signals is given. It is concluded that the neutronic processes involved in neutron noise are quite well understood, but that little is known about the density fluctuations in two-phase flow which are the main cause of the neutron noise. For this reason, the neutron noise measurements, like the well known two-detector velocity measurements, are still difficult to interpret. By analyzing neutron noise measurements in a natural circulation cooled BWR, it is illustrated that, once a theory on the density fluctuations is developed, two-phase flow can be monitored with a single in-core detector. (author). 70 refs, 4 figs

  2. Location of core diagnostic information across various sequences in brain MRI and implications for efficiency of MRI scanner utilization.

    Science.gov (United States)

    Sharma, Aseem; Chatterjee, Arindam; Goyal, Manu; Parsons, Matthew S; Bartel, Seth

    2015-04-01

    Targeting redundancy within MRI can improve its cost-effective utilization. We sought to quantify potential redundancy in our brain MRI protocols. In this retrospective review, we aggregated 207 consecutive adults who underwent brain MRI and reviewed their medical records to document clinical indication, core diagnostic information provided by MRI, and its clinical impact. Contributory imaging abnormalities constituted positive core diagnostic information whereas absence of imaging abnormalities constituted negative core diagnostic information. The senior author selected core sequences deemed sufficient for extraction of core diagnostic information. For validating core sequences selection, four readers assessed the relative ease of extracting core diagnostic information from the core sequences. Potential redundancy was calculated by comparing the average number of core sequences to the average number of sequences obtained. Scanning had been performed using 9.4±2.8 sequences over 37.3±12.3 minutes. Core diagnostic information was deemed extractable from 2.1±1.1 core sequences, with an assumed scanning time of 8.6±4.8 minutes, reflecting a potential redundancy of 74.5%±19.1%. Potential redundancy was least in scans obtained for treatment planning (14.9%±25.7%) and highest in scans obtained for follow-up of benign diseases (81.4%±12.6%). In 97.4% of cases, all four readers considered core diagnostic information to be either easily extractable from core sequences or the ease to be equivalent to that from the entire study. With only one MRI lacking clinical impact (0.48%), overutilization did not seem to contribute to potential redundancy. High potential redundancy that can be targeted for more efficient scanner utilization exists in brain MRI protocols.

  3. Monitoring of core barrel vibrations in WWER type reactor using out-of-reactor ionization chambers

    International Nuclear Information System (INIS)

    Dach, K.

    1982-01-01

    Vibration of the core barrel is least desirable for safe operation of the PWR reactor. These mechanical vibrations are in correlation with the fluctuations of neutron flux density whose time and frequency analysis serves failure diagnosis. The mathematical model is described of the transfer of mechanical vibrations of the core barrel to neutron noise. Other steps are indicated indispensable for the application of the method of neutron noise analysis for in-service diagnostics of nuclear power plants. (Z.M.)

  4. Research and Development Program in Reactor Diagnostics and Monitoring with Neutron Noise Methods. Stage 8. Final report

    International Nuclear Information System (INIS)

    Pazsit, I.; Demaziere, C.; Arzhanov, V.

    2003-01-01

    This report constitutes Stage 8 of a long-term research and development program concerning the development of diagnostics and monitoring methods for nuclear reactors. A brief proposal for the continuation of this program in stage 9 is also given at the end of the report. The program executed in Stage 8 consists of three parts and the work performed in each part is summarized below. In Stage 7, an anomaly localisation algorithm was presented and applied to the Forsmark-1 channel instability event. This investigation was carried out with a set of static data that were typical of a generic BWR model, since no data except the Local Power Range Monitors (LPRMs) time signals recorded during the instability event were made accessible to us at that time. In the present Stage, these static data were obtained from Vattenfall Fuel AB, who used the SIMULATE-3 code. The first Section of this report is thus devoted to this anomaly localisation but this time with a relevant set of data, both regarding the static core conditions and regarding the LPRMs time signals. The noise source pointed out by the localisation algorithm was once again found to be very close to an unseated fuel assembly discovered during the fuel outage following the instability event. The localisation procedure relies in fact on the prior calculation of the reactor transfer function, carried out via the neutron noise simulator first presented in Stage 6 and later improved in Stage 7. The neutron noise simulator was also improved in this Stage. More precisely, a 2-D 2- group static core simulator was developed in order to calculate the static flux and the associated eigenvalue with a spatial discretization scheme compatible with the one in use in the neutron noise simulator, i.e. finite differences. It has generally been assumed that the Decay Ratio (DR), a parameter characterizing the stability of BWRs, is a space-independent parameter of the reactor, i.e. it is independent of which LPRM is used in the core to

  5. Reactor noise diagnostics based on multivariate autoregressive modeling: Application to LOFT [Loss-of-Fluid-Test] reactor process noise

    International Nuclear Information System (INIS)

    Gloeckler, O.; Upadhyaya, B.R.

    1987-01-01

    Multivariate noise analysis of power reactor operating signals is useful for plant diagnostics, for isolating process and sensor anomalies, and for automated plant monitoring. In order to develop a reliable procedure, the previously established techniques for empirical modeling of fluctuation signals in power reactors have been improved. Application of the complete algorithm to operational data from the Loss-of-Fluid-Test (LOFT) Reactor showed that earlier conjectures (based on physical modeling) regarding the perturbation sources in a Pressurized Water Reactor (PWR) affecting coolant temperature and neutron power fluctuations can be systematically explained. This advanced methodology has important implication regarding plant diagnostics, and system or sensor anomaly isolation. 6 refs., 24 figs

  6. Wind turbine noise diagnostics

    International Nuclear Information System (INIS)

    Richarz, W.; Richarz, H.

    2009-01-01

    This presentation proposed a self-consistent model for broad-band noise emitted from modern wind turbines. The simple source model was consistent with the physics of sound generation and considered the unique features of wind turbines. Although the acoustics of wind turbines are similar to those of conventional propellers, the dimensions of wind turbines pose unique challenges in diagnosing noise emission. The general features of the sound field were deduced. Source motion and source directivity appear to be responsible for amplitude variations. The amplitude modulation is likely to make wind-turbine noise more audible, and may be partly responsible for annoyance that has been reported in the literature. Acoustic array data suggests that broad-band noise is emitted predominantly during the downward sweep of each rotor blade. Source motion and source directivity account for the observed pattern. Rotor-tower interaction effects are of lesser importance. Predicted amplitude modulation ranges from 1 dB to 6dB. 2 refs., 9 figs.

  7. Comment on the in-core measurement in the WWER nuclear power plant

    International Nuclear Information System (INIS)

    Krett, V.; Dach, K.; Erben, O.

    1985-01-01

    The activity of the Nuclear Research Institute (NRI) Rez in the field of in-core measurement sensors is described in the paper. The results of comparison and calibration experiments realized on the WWR-S research reactor at the NRI are presented. Measurements with fission calorimeters and SPN detectors carried out in the framework of diagnostic fuel assembly program of WWER NPP reactors are described. Noise measurements with detectors of in-core instrumentation of diagnostic fuel assemblies are also mentioned. Comparison experiments on the WWER-440 NPP reactor are described and the method of function verification of neutron sensors of the in-core control system of these reactors is given. (author)

  8. Hardware Implementation of LMS-Based Adaptive Noise Cancellation Core with Low Resource Utilization

    Directory of Open Access Journals (Sweden)

    Omid Sharifi Tehrani

    2011-10-01

    Full Text Available A hardware implementation of adaptive noise cancellation (ANC core is proposed. Adaptive filters are widely used in different applications such as adaptive noise cancellation, prediction, equalization, inverse modeling and system identification. FIR adaptive filters are mostly used because of their low computation costs and their linear phase. Least mean squared algorithm (LMS is used to train FIR adaptive filter weights. Advances in semiconductor technology especially in digital signal processors (DSP and field programmable gate arrays (FPGA with hundreds of mega hertz in speed, will allow digital designers to embed essential digital signal processing units in small chips. But designing a synthesizable core on an FPGA is not always as simple as DSP chips due to complexity and limitations of FPGAs. In this paper we design anLMS-based FIR adaptive filter for adaptive noise cancellation based on VHDL97 hardware description language (HDL and Xilinx SPARTAN3E (XC3S500E which utilizes low resources and is high performance and FPGA-brand independent so can be implemented on different FPGA brands (Xilinx, ALTERA, ACTEL. Simulations are done in MODELSIM and MATLAB and implementation is done with Xilinx ISE. Finally, result are compared with other papers for better judgment.

  9. Study of core support barrel vibration monitoring using ex-core neutron noise analysis and fuzzy logic algorithm

    International Nuclear Information System (INIS)

    Christian, Robby; Song, Seon Ho; Kang, Hyun Gook

    2015-01-01

    The application of neutron noise analysis (NNA) to the ex-core neutron detector signal for monitoring the vibration characteristics of a reactor core support barrel (CSB) was investigated. Ex-core flux data were generated by using a nonanalog Monte Carlo neutron transport method in a simulated CSB model where the implicit capture and Russian roulette technique were utilized. First and third order beam and shell modes of CSB vibration were modeled based on parallel processing simulation. A NNA module was developed to analyze the ex-core flux data based on its time variation, normalized power spectral density, normalized cross-power spectral density, coherence, and phase differences. The data were then analyzed with a fuzzy logic module to determine the vibration characteristics. The ex-core neutron signal fluctuation was directly proportional to the CSB's vibration observed at 8Hz and15Hzin the beam mode vibration, and at 8Hz in the shell mode vibration. The coherence result between flux pairs was unity at the vibration peak frequencies. A distinct pattern of phase differences was observed for each of the vibration models. The developed fuzzy logic module demonstrated successful recognition of the vibration frequencies, modes, orders, directions, and phase differences within 0.4 ms for the beam and shell mode vibrations.

  10. Embedded Acoustic Sensor Array for Engine Fan Noise Source Diagnostic Test: Feasibility of Noise Telemetry via Wireless Smart Sensors

    Science.gov (United States)

    Zaman, Afroz; Bauch, Matthew; Raible, Daniel

    2011-01-01

    Aircraft engines have evolved into a highly complex system to meet ever-increasing demands. The evolution of engine technologies has primarily been driven by fuel efficiency, reliability, as well as engine noise concerns. One of the sources of engine noise is pressure fluctuations that are induced on the stator vanes. These local pressure fluctuations, once produced, propagate and coalesce with the pressure waves originating elsewhere on the stator to form a spinning pressure pattern. Depending on the duct geometry, air flow, and frequency of fluctuations, these spinning pressure patterns are self-sustaining and result in noise which eventually radiate to the far-field from engine. To investigate the nature of vane pressure fluctuations and the resulting engine noise, unsteady pressure signatures from an array of embedded acoustic sensors are recorded as a part of vane noise source diagnostics. Output time signatures from these sensors are routed to a control and data processing station adding complexity to the system and cable loss to the measured signal. "Smart" wireless sensors have data processing capability at the sensor locations which further increases the potential of wireless sensors. Smart sensors can process measured data locally and transmit only the important information through wireless communication. The aim of this wireless noise telemetry task was to demonstrate a single acoustic sensor wireless link for unsteady pressure measurement, and thus, establish the feasibility of distributed smart sensors scheme for aircraft engine vane surface unsteady pressure data transmission and characterization.

  11. Enhanced NIF neutron activation diagnostics.

    Science.gov (United States)

    Yeamans, C B; Bleuel, D L; Bernstein, L A

    2012-10-01

    The NIF neutron activation diagnostic suite relies on removable activation samples, leading to operational inefficiencies and a fundamental lower limit on the half-life of the activated product that can be observed. A neutron diagnostic system measuring activation of permanently installed samples could remove these limitations and significantly enhance overall neutron diagnostic capabilities. The physics and engineering aspects of two proposed systems are considered: one measuring the (89)Zr/(89 m)Zr isomer ratio in the existing Zr activation medium and the other using potassium zirconate as the activation medium. Both proposed systems could improve the signal-to-noise ratio of the current system by at least a factor of 5 and would allow independent measurement of fusion core velocity and fuel areal density.

  12. Noise Budget for the X-Ray Microcalorimeter Spectrometer (XMS) Core Array

    Science.gov (United States)

    Kilbourne, Caroline Anne

    2010-01-01

    The purpose of this document is to present and archive the noise budget for the XMS detector, in order, at this stage in mission planning, to learn the scale of the requirements placed on the other instrument subsystems. This document mainly concerns the core array, specifically the baseline version that emerged from the trade studies associated with the ESA Phase A study report. Qualitative extension to the Hydra approach to the outer array is included at the end.

  13. Prompt Neutron Decay Constant Determination Of Silicide Transition Core Using Noise Method

    International Nuclear Information System (INIS)

    Jujuratisbela, Uju; Yulianto, Yusi Eko; Cahyana

    2001-01-01

    Chairman of BATAN had decided to replace the Oxide fuel element type of RSG-GAS into silicide element type step by step. The replacement will create core transitions. Kinetic characteristic of the transition cores have to be monitored in order to know the deviation of core behavior. For that reason, the kinetic parameters have to be measured. Prompt neutron decay constant (alpha) is one of the kinetic parameters that has to be monitored continuously in the transition cores. In order not to disturb the normal operation of reactor, alpha parameter should be measured by using noise analysis method. The voltage of neutron flux at power of 15 MW is connected to preamplifier and filter then to the Dynamic Signal Analyzer Version-2 and then the auto power spectral density (APSD) was determined by using Fast Fourier transform. From the APSD curve of each channel of JKT03, the cut off frequency of each channel can be determined by using linear regression technique such that the prompt neutron decay constant can be estimated

  14. Functional requirements for core surveillance systems

    International Nuclear Information System (INIS)

    Andersson, T.

    2000-01-01

    Operating experience at Ringhals-2 has demonstrated the feasibility of a mixed core surveillance system comprised of fixed in-core detectors combined with the original movable detector system. A small number of fixed in-core detectors provide continuous measurement of the thermal margins while the movable detectors are used mainly at start-up to verify the expected power distribution. Reactor noise diagnostics and neural networks can further improve the monitoring system. The reliability of the movable detector system can be improved by mechanical simplification. Wear and maintenance costs are lowered if the required flux-mapping frequency is reduced. Improved computer codes make the measurement uncertainties less dependent on the number of instrumented positions. A mixed system requires new types of technical specifications. (author)

  15. Image processing methods for noise reduction in the TJ-II Thomson Scattering diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Dormido-Canto, S., E-mail: sebas@dia.uned.es [Departamento de Informatica y Automatica, UNED, Madrid 28040 (Spain); Farias, G. [Pontificia Universidad Catolica de Valparaiso, Valparaiso (Chile); Vega, J.; Pastor, I. [Asociacion EURATOM/CIEMAT para Fusion, Madrid 28040 (Spain)

    2012-12-15

    Highlights: Black-Right-Pointing-Pointer We describe an approach in order to reduce or mitigate the stray-light on the images and show the exceptional results. Black-Right-Pointing-Pointer We analyze the parameters to take account in the proposed process. Black-Right-Pointing-Pointer We report a simplified exampled in order to explain the proposed process. - Abstract: The Thomsom Scattering diagnostic of the TJ-II stellarator provides temperature and density profiles. The CCD camera acquires images corrupted with noise that, in some cases, can produce unreliable profiles. The main source of noise is the so-called stray-light. In this paper we describe an approach that allows mitigation of the effects that stray-light has on the images: extraction regions with connected-components. In addition, the robustness and effectiveness of the noise reduction technique is validated in two ways: (1) supervised classification and (2) comparison of electron temperature profiles.

  16. An Advanced Diagnostic Display for Core Protection Calculator System

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji-Hyeon; Jeong, See-Chae; Sohn, Se-Do [Korea Power Engineering Company, Daejeon (Korea, Republic of)

    2008-10-15

    The main purpose of a Nuclear Power Plant Instrumentation and Control (I and C) Display System is to provide operator's interface for I and C systems. The CPCS display(Shin-Kori 1 and 2) provides operators with 1) plant monitoring values of field input and algorithm variables that reflect the reactor core conditions, 2) operation values that operators can change and 3) CPCS status. It will be an optimal case if operators can understand the plant (including CPCS itself) condition intuitively with the displayed values but it is not easy in CPCS. For example, if the CPCS Channel Trouble light is lit, operators need some amount of time to investigate what caused the trouble light because there are more than hundred causes that can generate the channel trouble. If a Display supports diagnostic information that shows what cause the displayed alarms, it will greatly help operators in easy understanding the CPCS status. To provide these diagnostic information, this paper suggests an active self-explanatory display mechanism. This self-explanatory diagnostic display mechanism utilizes an ontology in XML that describes parent child, sibling relationships of display variables, through which in-depth, in-breadth diagnostic tracking is possible. This paper consists of two parts. First, the key features of CPCS Flat Panel Display System (FPDS) are described. Second, the features of active self explanatory diagnostic display are discussed.

  17. An Advanced Diagnostic Display for Core Protection Calculator System

    International Nuclear Information System (INIS)

    Kim, Ji-Hyeon; Jeong, See-Chae; Sohn, Se-Do

    2008-01-01

    The main purpose of a Nuclear Power Plant Instrumentation and Control (I and C) Display System is to provide operator's interface for I and C systems. The CPCS display(Shin-Kori 1 and 2) provides operators with 1) plant monitoring values of field input and algorithm variables that reflect the reactor core conditions, 2) operation values that operators can change and 3) CPCS status. It will be an optimal case if operators can understand the plant (including CPCS itself) condition intuitively with the displayed values but it is not easy in CPCS. For example, if the CPCS Channel Trouble light is lit, operators need some amount of time to investigate what caused the trouble light because there are more than hundred causes that can generate the channel trouble. If a Display supports diagnostic information that shows what cause the displayed alarms, it will greatly help operators in easy understanding the CPCS status. To provide these diagnostic information, this paper suggests an active self-explanatory display mechanism. This self-explanatory diagnostic display mechanism utilizes an ontology in XML that describes parent child, sibling relationships of display variables, through which in-depth, in-breadth diagnostic tracking is possible. This paper consists of two parts. First, the key features of CPCS Flat Panel Display System (FPDS) are described. Second, the features of active self explanatory diagnostic display are discussed

  18. Vibration and acoustic noise emitted by dry-type air-core reactors under PWM voltage excitation

    Science.gov (United States)

    Li, Jingsong; Wang, Shanming; Hong, Jianfeng; Yang, Zhanlu; Jiang, Shengqian; Xia, Shichong

    2018-05-01

    According to coupling way between the magnetic field and the structural order, structure mode is discussed by engaging finite element (FE) method and both natural frequency and modal shape for a dry-type air-core reactor (DAR) are obtained in this paper. On the basis of harmonic response analysis, electromagnetic force under PWM (Pulse Width Modulation) voltage excitation is mapped with the structure mesh, the vibration spectrum is gained and the consequences represents that the whole structure vibration predominates in the radial direction, with less axial vibration. Referring to the test standard of reactor noise, the rules of emitted noise of the DAR are measured and analyzed at chosen switching frequency matches the sample resonant frequency and the methods of active vibration and noise reduction are put forward. Finally, the low acoustic noise emission of a prototype DAR is verified by measurement.

  19. Investigation of space-energy effects in the reactivity measurement by neutron noise with ex-core detectors in a reflected LWR

    International Nuclear Information System (INIS)

    Lescano, V.H.; Behringer, K.

    1981-11-01

    Practical application of the zero-crossing correlation method for measuring slightly subcritical reactivities in a swimming pool reactor required the use of detector locations in the reflector zone near to the core boundary. Experimental investigations of neutron-noise cross-power spectra showed significant deviations from the point reactor model at higher frequencies (> 100 Hz). Nevertheless, the use of the point reactor model was found to be an useful approach in the analysis of the zero-crossing correlation method yielding results which agreed well with those obtained from the rod-drop method. The theoretical part of the work is concerned with a space-dependent model calculation in two-group diffusion theory to support the experimental findings. The model calculation can explain the trends observed in the neutron-noise spectra as well as the applicability of the point reactor model to the zero-crossing correlation method. To obtain better insight, the calculations have been extended to neutron-noise spectra when one or both detectors are located in the core zone. In the case of a large core and widely spaced detectors, with at least one detector in the core zone, a sink frequency appears in the spectra. This effect is well-known in coupled-core kinetics. (Auth.)

  20. Modeling and diagnostic techniques applicable to the analysis of pressure noise in pressurized water reactors and pressure-sensing systems

    International Nuclear Information System (INIS)

    Mullens, J.A.; Thie, J.A.

    1984-01-01

    Pressure noise data from a PWR are interpreted by means of a computer-implemented model. The model's parameters, namely hydraulic impedances and noise sources, are either calculated or deduced from fits to data. Its accuracy is encouraging and raises the possibility of diagnostic assistance for nuclear plant monitoring. A number of specific applications of pressure noise in the primary system of a PWR and in a pressure sensing system are suggested

  1. Using noise diagnostics for detection and monitoring of vibrations of RPV internals, and for cause analysis in Eastern German NPP with WWER-440/230 type reactors of the Russian design type

    International Nuclear Information System (INIS)

    Schumann, P.

    2000-10-01

    The report explains in detail applications and results of noise diagnostic measurements for examining vibrations which caused damage to reactor pressure vessel internals. The vibrations investigated were observed in 1975 and 1985 at the WWER-440/230 type reactors of the Russian design installed in units 1 and 2 of the Greifswald nuclear power plant, and were identified as dominant control element vibrations and abnormal core basket movements. The report presents essential operating characteristics recorded during disturbed reactor operation, the inspection results, and characteristic experimental findings from noise signal analyses and special tests examining the physical aspects of the vibration processes and their causes. Some recommendations have been derived relating to monitoring and minimization of such vibrations. (orig./CB) [de

  2. Implementation of New Reactivity Measurement System and New Reactor Noise Analysis Equipment in a VVER-440 Nuclear Power Plant

    Science.gov (United States)

    Vegh, János; Kiss, Sándor; Lipcsei, Sándor; Horvath, Csaba; Pos, István; Kiss, Gábor

    2010-10-01

    The paper deals with two recently developed, high-precision nuclear measurement systems installed at the VVER-440 units of the Hungarian Paks NPP. Both developments were motivated by the reactor power increase to 108%, and by the planned plant service time extension. The first part describes the RMR start-up reactivity measurement system with advanced services. High-precision picoampere meters were installed at each reactor unit and measured ionization chamber current signals are handled by a portable computer providing data acquisition and online reactivity calculation service. Detailed offline evaluation and analysis of reactor start-up measurements can be performed on the portable unit, too. The second part of the paper describes a new reactor noise diagnostics system using state-of-the-art data acquisition hardware and signal processing methods. Details of the new reactor noise measurement evaluation software are also outlined. Noise diagnostics at Paks NPP is a standard tool for core anomaly detection and for long-term noise trend monitoring. Regular application of these systems is illustrated by real plant data, e.g., results of standard reactivity measurements during a reactor startup session are given. Noise applications are also illustrated by real plant measurements; results of core anomaly detection are presented.

  3. Diagnostic accuracy of 22/25-gauge core needle in endoscopic ultrasound-guided sampling: systematic review and meta-analysis.

    Science.gov (United States)

    Oh, Hyoung-Chul; Kang, Hyun; Lee, Jae Young; Choi, Geun Joo; Choi, Jung Sik

    2016-11-01

    To compare the diagnostic accuracy of endoscopic ultrasound-guided core needle aspiration with that of standard fine-needle aspiration by systematic review and meta-analysis. Studies using 22/25-gauge core needles, irrespective of comparison with standard fine needles, were comprehensively reviewed. Pooled sensitivity, specificity, diagnostic odds ratio (DOR), and summary receiver operating characteristic curves for the diagnosis of malignancy were used to estimate the overall diagnostic efficiency. The pooled sensitivity, specificity, and DOR of the core needle for the diagnosis of malignancy were 0.88 (95% confidence interval [CI], 0.84 to 0.90), 0.99 (95% CI, 0.96 to 1), and 167.37 (95% CI, 65.77 to 425.91), respectively. The pooled sensitivity, specificity, and DOR of the standard needle were 0.84 (95% CI, 0.79 to 0.88), 1 (95% CI, 0.97 to 1), and 130.14 (95% CI, 34.00 to 495.35), respectively. The area under the curve of core and standard needle in the diagnosis of malignancy was 0.974 and 0.955, respectively. The core and standard needle were comparable in terms of pancreatic malignancy diagnosis. There was no significant difference in procurement of optimal histologic cores between core and standard needles (risk ratio [RR], 0.545; 95% CI, 0.187 to 1.589). The number of needle passes for diagnosis was significantly lower with the core needle (standardized mean difference, -0.72; 95% CI, -1.02 to -0.41). There were no significant differences in overall complications (RR, 1.26; 95% CI, 0.34 to 4.62) and technical failure (RR, 5.07; 95% CI, 0.68 to 37.64). Core and standard needles were comparable in terms of diagnostic accuracy, technical performance, and safety profile.

  4. Results and interpretation of noise measurements using in-core self powered neutron detector strings at Unit 2 of the Paks Nuclear Power Plant

    International Nuclear Information System (INIS)

    Gloeckler, O.; Por, G.; Valko, J.

    1986-11-01

    In-core neutron noise and fuel assembly outlet temperature noise measurements were performed at Unit 2 of Paks Nuclear Power Plant. Characteristics of the reactor and the noise measuring equipment are briefly described. The in-core Rhodium emitter selfpowered neutron detector strings positioned axially above the other show high coherence and linear phase at low frequencies indicating a marked transport effect, not regularly measured in PWRs. The coherence between horizontally placed neutron detectors is small and the phase is zero. A transport effect of different nature is obtained between neutron detectors (in-core and ex-core) and fuel assembly outlet thermocouples. The observed characteristics depend on reactor and fuel assembly power in a way supporting interpretation in terms of coolant density and void content changes and power feedback effects. During routine analysis vibration of 1.1 Hz appeared as a strong peak in the power spectra. The control assembly that was responsible for the observed behaviour could be localized with high certainty. (author)

  5. Studies on neutron noise diagnostics of control rod vibrations by neural networks; Obtencion de U{sub 3}O{sub 8} y UO{sub 2} a partir de ADU (diuranato amonico) precipitado con aplicacion de ultrasonido

    Energy Technology Data Exchange (ETDEWEB)

    Roston, G; Kozma, R; Kitamura, M [Tohoku Univ., Sendai (Japan); Garis, N S; Pazsit, I [Chalmers Univ. of Technology, Goeteborg (Sweden). Dept. of Reactor Physics

    1997-12-31

    This work is focussed on the study of a neutron noise based technique for the diagnostics of reactor core internal, in particular, excessively vibrating control rods. The use of a combination of physical models and neural networks offers an alternative way of performing the inversion procedure. The application of a neural network technique to determine the rod position from the detector spectra is much faster, more effective and simpler to use than the conventional method. (author). 5 refs., 1 fig., 1 tab.

  6. Meta-Review of CSF core biomarkers in Alzheimer’s disease: the state-of-the-art after the new revised diagnostic criteria

    Directory of Open Access Journals (Sweden)

    Daniel eFerreira

    2014-03-01

    Full Text Available Background: Current research criteria for Alzheimer’s disease (AD include Cerebrospinal Fluid (CSF biomarkers into the diagnostic algorithm. However, spreading their use to the clinical routine is still questionable. Objective: To provide an updated, systematic and critical review on the diagnostic utility of the CSF core biomarkers for AD. Data sources: MEDLINE, PreMedline, EMBASE, PsycInfo, CINAHL, Cochrane Library, and CRD.Eligibility criteria: 1a Systematic reviews with meta-analysis; 1b Primary studies published after the new revised diagnostic criteria; 2 Evaluation of the diagnostic performance of at least one CSF core biomarker.Results: The diagnostic performance of CSF biomarkers is generally satisfactory. They are optimal for discriminating AD patients from healthy controls. Their combination may also be suitable for Mild Cognitive Impairment (MCI prognosis. However, CSF biomarkers fail to distinguish AD from other forms of dementia. Limitations: 1 use of clinical diagnosis as standard instead of pathological postmortem confirmation; 2 variability of methodological aspects; 3 insufficiently long follow-up periods in MCI studies; and 4 lower diagnostic accuracy in primary care compared with memory clinics. Conclusions: Additional work needs to be done to validate the application of CSF core biomarkers as they are proposed in the new revised diagnostic criteria. The use of CSF core biomarkers in clinical routine is more likely if these limitations are overcome. Early diagnosis is going to be of utmost importance when effective pharmacological treatment will be available and the CSF core biomarkers can also be implemented in clinical trials for drug development.

  7. Meta-Review of CSF Core Biomarkers in Alzheimer’s Disease: The State-of-the-Art after the New Revised Diagnostic Criteria

    Science.gov (United States)

    Ferreira, Daniel; Perestelo-Pérez, Lilisbeth; Westman, Eric; Wahlund, Lars-Olof; Sarría, Antonio; Serrano-Aguilar, Pedro

    2014-01-01

    Background: Current research criteria for Alzheimer’s disease (AD) include cerebrospinal fluid (CSF) biomarkers into the diagnostic algorithm. However, spreading their use to the clinical routine is still questionable. Objective: To provide an updated, systematic and critical review on the diagnostic utility of the CSF core biomarkers for AD. Data sources: MEDLINE, PreMedline, EMBASE, PsycInfo, CINAHL, Cochrane Library, and CRD. Eligibility criteria: (1a) Systematic reviews with meta-analysis; (1b) Primary studies published after the new revised diagnostic criteria; (2) Evaluation of the diagnostic performance of at least one CSF core biomarker. Results: The diagnostic performance of CSF biomarkers is generally satisfactory. They are optimal for discriminating AD patients from healthy controls. Their combination may also be suitable for mild cognitive impairment (MCI) prognosis. However, CSF biomarkers fail to distinguish AD from other forms of dementia. Limitations: (1) Use of clinical diagnosis as standard instead of pathological postmortem confirmation; (2) variability of methodological aspects; (3) insufficiently long follow-up periods in MCI studies; and (4) lower diagnostic accuracy in primary care compared with memory clinics. Conclusion: Additional work needs to be done to validate the application of CSF core biomarkers as they are proposed in the new revised diagnostic criteria. The use of CSF core biomarkers in clinical routine is more likely if these limitations are overcome. Early diagnosis is going to be of utmost importance when effective pharmacological treatment will be available and the CSF core biomarkers can also be implemented in clinical trials for drug development. PMID:24715863

  8. Acoustic noise diagnostics of leaks. Report of the E O Paton Electric Welding Institute, Kiev, 1997

    International Nuclear Information System (INIS)

    Volkov, L.P.; Zverev, A.F.; Kozeletskii, V.F.; Leonov, A.N.

    1999-01-01

    Special attention has been paid in recent years to safe service of nuclear energy plant (NEP): various safety programmes are being developed and applied, measures are taken in reactors of the WWER-RBMK type, the Gospromatomnadzor is introducing a package of new standard requirements and documents, etc. Formation of leaks in equipment and pipelines, actual leakage and the discharge of the heat carrier outside the limits of contour I of the NEP leads to undesirable and sometimes serious consequences. In most cases, elimination of these consequences is associated with the need to use a large amount of material, personnel, shutdown of nuclear equipment, disruption of the ecological situation, and partial or complete loss of electric or thermal power. The 'leak prior to fracture' concept, accepted several years ago in the EEC countries and the USA has been used as a strong impetus for the rapid development of diagnostic means of inspection of pipelines and equipment, including acoustic equipment. The development of means of acoustic leak detection as a variety of noise diagnostics is still important because the utilisation of the possibilities of the methods of noise diagnostics makes it possible to solve a complex problem: recording the actual leakage event, determination of its position and the degree of risk. The majority of modern leak inspection methods, having a low sensitivity threshold, require development of special testing conditions, the use of indicator or test substances and, most importantly, they should not be remote controlled. For example, the mass spectrometric, halide, luminescent, bubble and capillary methods have a sensitivity threshold of 6.7·10 -11 -6.7·10 -4 m 3 Pa/s, but require the presence of an operator in the inspection area. The use of these methods for determining leakage in pipelines and equipment of nuclear power plant is out of the question and it is not possible to develop a system for remote control of NEP equipment using these

  9. Nuclear reactor pump diagnostics via noise analysis/artificial neural networks

    International Nuclear Information System (INIS)

    Keyvan, S.; Rabelo, L.C.

    1991-01-01

    A feasibility study is performed on the utilization of artificial neural networks as a tool for reactor diagnostics. Reactor pump signals utilized in a wear-out monitoring system developed for early detection of degradation of pump shaft are analyzed as a semi-benchmark test to study the feasibility of neural networks for pattern recognition. The Adaptive Resonance Theory (ART 2) paradigm of artificial neural networks is applied in this study. The signals are collected signals as well as generated signals simulating the wear progress. The wear-out monitoring system applies noise analysis techniques, and is capable of distinguishing between these signals and providing a measure of the progress of the degradation. This paper presents the results of the analysis of these data via the ART 2 paradigm

  10. Status of the R&D activities to the design of an ITER core CXRS diagnostic system

    Energy Technology Data Exchange (ETDEWEB)

    Mertens, Philippe, E-mail: ph.mertens@fz-juelich.de [Institute of Energy and Climate Research IEK-4 (Plasma Physics), Forschungszentrum Jülich (FZJ), Trilateral Euregio Cluster, D-52425 Jülich (Germany); Castaño Bardawil, David A. [Institute of Energy and Climate Research IEK-4 (Plasma Physics), Forschungszentrum Jülich (FZJ), Trilateral Euregio Cluster, D-52425 Jülich (Germany); Baross, Tétény [Wigner Research Centre for Physics (Wigner RCP), HU-1121 Budapest (Hungary); Biel, Wolfgang; Friese, Sebastian [Institute of Energy and Climate Research IEK-4 (Plasma Physics), Forschungszentrum Jülich (FZJ), Trilateral Euregio Cluster, D-52425 Jülich (Germany); Hawkes, Nick [Culham Centre for Fusion Energy (CCFE), Culham OX14 3DB (United Kingdom); Jaspers, Roger J.E. [Eindhoven University of Technology (TU/e), PO Box 513, NL-5600 MB Eindhoven (Netherlands); Kotov, Vladislav; Krasikov, Yury; Krimmer, Andreas; Litnovsky, Andrey; Marchuk, Oleksander; Neubauer, Olaf [Institute of Energy and Climate Research IEK-4 (Plasma Physics), Forschungszentrum Jülich (FZJ), Trilateral Euregio Cluster, D-52425 Jülich (Germany); Offermanns, Guido [Zentralinstitut für Engineering, Elektronik und Analytik ZEA-1 (Engineering and Technology), FZJ, Trilateral Euregio Cluster, D-52425 Jülich (Germany); Panin, Anatoly [Institute of Energy and Climate Research IEK-4 (Plasma Physics), Forschungszentrum Jülich (FZJ), Trilateral Euregio Cluster, D-52425 Jülich (Germany); and others

    2015-10-15

    Highlights: • The CXRS diagnostic for the core plasma of ITER will provide observation of the dedicated diagnostic beam (DNB) over a wide radial range, roughly r/a = 0.7 to 0. • A high performance (étendue × transmission, dynamic range) is expected for the port plug system since the beam attenuation is large and the background light omnipresent. • The design is particularly challenging in view of the ITER environment, especially with respect to the first mirror which faces the plasma. • The current status of development is presented by detailing several sub-systems before a four years design phase under an FPA between F4E and the ITER core CXRS Consortium (IC3). - Abstract: The CXRS (Charge-eXchange Recombination Spectroscopy) diagnostic for the core plasma of ITER will be designed to provide observation of the dedicated diagnostic beam (DNB) over a wide radial range, roughly from a normalised radius r/a = 0.7 to close to the plasma axis. The collected light will be transported through the Upper Port Plug #3 (UPP3) to a bundle of fibres and ultimately to a set of remote spectrometers. The design is particularly challenging in view of the ITER environment of particle, heat and neutron fluxes, temperature cycles, electromagnetic loads, vibrations, expected material degradation and fatigue, constraints against tritium penetration, integration in the plug and limited opportunities for maintenance. Moreover, a high performance (étendue × transmission, dynamic range) is expected for the port plug system since the beam attenuation is large and the background light omnipresent, especially in terms of bremsstrahlung, line radiation and reflections. The present contribution will give an overview of the current status and activities which deal with the core CXRS system, summarising the investigations which have taken place before entering the actual development and design phase.

  11. Power noise spectrum classification in the problem of the IBR-2 reactor

    International Nuclear Information System (INIS)

    Bargel, M.; Kitowski, J.; Pepelyshev, Yu.N.

    1988-01-01

    The classification spectrum results of random fluctuations in the IBR-2 energy pulse are presented. The work is performed for the application of the obtained results to the reactor diagnostics and the study of its noise uncontrolled states. For classification of the spectra the method of pattern recognition based upon the ISODATA heuristic algorithm is used. It is shown that a set of noise uncontrolled reactor states, registered during the reactor operation period at power of 0.4-2 MVt with the first variant of moving reflector (1983-1986) is formed into 4(5) most typical states. Each of the states corresponds to the general conditions of the reactor core cooling and provides the normal work of the moving reflector. However, these states differ in coolant flow, power level and peculiarities of the moving reflector rotation regime. One type of anomal power noise, connected with some disorder in the moving reflctor work, is isolated. This work also presents the possibility of control over the state of moving reflectors according to the change in the amplitude of power oscillations at some frequences. The reactor noise classification results can be used as the data bank for the IBR-2 reactor diagnostic system

  12. Fast measurements of the in-core coolant velocity in a BWR by neutron noise analysis

    International Nuclear Information System (INIS)

    Hagen, T.H.J.J. van der; Hoogenboom, J.E.

    1988-01-01

    A method to determine in-core coolant velocities from neutron noise within short time intervals has been developed. The accuracy of the method was determined by using a simulation set-up and by using signals of a twin self-powered neutron detector installed in the core of the Dodewaard BWR in the Netherlands. In-core coolant velocities can be estimated within 2.5 s with a standard deviation (due to statistics) less than 2.1%. The method is suitable for velocity monitoring as is shown by the application to a stepwise velocity change of the coolant in a model of a coolant channel of a BWR. The presented technique was applied to determine the variations of the coolant velocity in the Dodewaard core during normal operation and during pressure steps. Only minor variations of the coolant velocity were detected during normal reactor conditions. An increase of those variations with pressure lowering - indicating a lower thermal hydraulic stability - could be detected. A clear velocity response to pressure steps could be determined which was also reflected in the cross-spectrum of the velocity with the vessel pressure and with the in-core neutron flux. (author)

  13. The circuit of polychromator for Experimental Advanced Superconducting Tokamak edge Thomson scattering diagnostic

    International Nuclear Information System (INIS)

    Zang, Qing; Zhao, Junyu; Chen, Hui; Li, Fengjuan; Hsieh, C. L.

    2013-01-01

    The detector circuit is the core component of filter polychromator which is used for scattering light analysis in Thomson scattering diagnostic, and is responsible for the precision and stability of a system. High signal-to-noise and stability are primary requirements for the diagnostic. Recently, an upgraded detector circuit for weak light detecting in Experimental Advanced Superconducting Tokamak (EAST) edge Thomson scattering system has been designed, which can be used for the measurement of large electron temperature (T e ) gradient and low electron density (n e ). In this new circuit, a thermoelectric-cooled avalanche photodiode with the aid circuit is involved for increasing stability and enhancing signal-to-noise ratio (SNR), especially the circuit will never be influenced by ambient temperature. These features are expected to improve the accuracy of EAST Thomson diagnostic dramatically. Related mechanical construction of the circuit is redesigned as well for heat-sinking and installation. All parameters are optimized, and SNR is dramatically improved. The number of minimum detectable photons is only 10

  14. Low-noise cable for diagnostics, control and instrumentation of the ASDEX tokamak fusion experiment

    International Nuclear Information System (INIS)

    Gernhardt, J.

    1988-11-01

    ASDEX (Axially Symmetric Divertor EXperiment) is a large tokamak (R=1.65 m; a=0.4 m) with an air transformer. The relatively large stray field, Bz=10 mT=(100 G); for ρ=5 m, Bz=40 mT=(400 G); for ρ=3 m, BΦ=0.3 T=(3 kG); for ρ=3m, compared with that of an iron transformer, and the cable length 1≤30 m from the experiment to the control room, make mainly the magnetically induced and capacitively coupled noise signal in the cable relatively high. As a result of neutral injection (> 4 MW; 40 kV) and lower hybrid ion cyclotron and Alfven wave heating strong E-fields are produced and noise is coupled into the cables. These magnetic and electric field gradients during the plasma shot vary with time and location. This report tries to show how these noise signals can be reduced without reducing the broadcast frequency of the signal. The Electro Magnetic Compatibility and Interference (EMC, EMI) are discussed. The cost of diagnostic cable, connectors and cable ducts without mounting is approximately DM 700,000.--. (orig.)

  15. Ultrasound-guided diagnostic breast biopsy methodology: retrospective comparison of the 8-gauge vacuum-assisted biopsy approach versus the spring-loaded 14-gauge core biopsy approach

    Science.gov (United States)

    2011-01-01

    Background Ultrasound-guided diagnostic breast biopsy technology represents the current standard of care for the evaluation of indeterminate and suspicious lesions seen on diagnostic breast ultrasound. Yet, there remains much debate as to which particular method of ultrasound-guided diagnostic breast biopsy provides the most accurate and optimal diagnostic information. The aim of the current study was to compare and contrast the 8-gauge vacuum-assisted biopsy approach and the spring-loaded 14-gauge core biopsy approach. Methods A retrospective analysis was done of all ultrasound-guided diagnostic breast biopsy procedures performed by either the 8-gauge vacuum-assisted biopsy approach or the spring-loaded 14-gauge core biopsy approach by a single surgeon from July 2001 through June 2009. Results Among 1443 ultrasound-guided diagnostic breast biopsy procedures performed, 724 (50.2%) were by the 8-gauge vacuum-assisted biopsy technique and 719 (49.8%) were by the spring-loaded 14-gauge core biopsy technique. The total number of false negative cases (i.e., benign findings instead of invasive breast carcinoma) was significantly greater (P = 0.008) in the spring-loaded 14-gauge core biopsy group (8/681, 1.2%) as compared to in the 8-gauge vacuum-assisted biopsy group (0/652, 0%), with an overall false negative rate of 2.1% (8/386) for the spring-loaded 14-gauge core biopsy group as compared to 0% (0/148) for the 8-gauge vacuum-assisted biopsy group. Significantly more (P guided diagnostic breast biopsy procedure. Significantly more (P guided diagnostic breast biopsy procedure. Conclusions In appropriately selected cases, the 8-gauge vacuum-assisted biopsy approach appears to be advantageous to the spring-loaded 14-gauge core biopsy approach for providing the most accurate and optimal diagnostic information. PMID:21835024

  16. Development and applications of reactor noise analysis at Ontario Hydro's CANDU reactors

    International Nuclear Information System (INIS)

    Gloeckler, O.; Tulett, M.V.

    1995-01-01

    In 1992 a program was initiated to establish reactor noise analysis as a practical tool for plant performance monitoring and system diagnostics in Ontario Hydro's CANDU reactors. Since then, various CANDU-specific noise analysis applications have been developed and validated. The noise-based statistical techniques are being successfully applied as powerful troubleshooting and diagnostic tools to a wide variety of actual operational I and C problems. The dynamic characteristics of critical plant components, instrumentation and processes are monitored on a regular basis. Recent applications of noise analysis include (1) validating the dynamics of in-core flux detectors (ICFDS) and ion chambers, (2) estimating the prompt fraction ICFDs in noise measurements at full power and in power rundown tests, (3) identifying the cause of excessive signal fluctuations in certain flux detectors, (4) validating the dynamic coupling between liquid zone control signals, (5) detecting and monitoring mechanical vibrations of detector tubes induced by moderator flow, (6) estimating the dynamics and response time of RTD (Resistance Temperature Detector) temperature signals, (7) isolating the cause of RTD signal anomalies, (8) investigating the source of abnormal flow signal behaviour, (9) estimating the overall response time of flow and pressure signals, (10) detecting coolant boiling in fully instrumented fuel channels, (11) monitoring moderator circulation via temperature noise, and (12) predicting the performance of shut-off rods. Some of these applications are performed on an as-needed basis. The noise analysis program, in the Pickering-B station alone, has saved Ontario Hydro millions of dollars during its first three years. The results of the noise analysis program have been also reviewed by the regulator (Atomic Energy Control Board of Canada) with favorable results. The AECB have expressed interest in Ontario Hydro further exploiting the use of noise analysis technology. (author

  17. The Multi一physics Research on I ron一Core Vibration Noise of Power Reactor

    Directory of Open Access Journals (Sweden)

    LI U Ja

    2017-02-01

    Full Text Available On the basis of theoretical research releted to the magnetostriction and maxwell’.s equations,the fi- nite element coupling in the transient electromagnetic field coupling,structure and sound field coupling has been developed In thts paper by using the flnlte element sOftWare CO}IS01., Whleh establish a serles three-phase COT’e re- actor model, to analyzing the power frequency magnetic field distribution,core magnetostrictive displacement,max- well force displacement and sound pressure level of the three-phase series core reactor under the power frequency working state. According to transient magnetic field distribution in the simulation of the reactor,the magnetic flux density distribution inside the reactor and the vibration displacement distribution are calculated,the acoustic field distribution is measured alao. It is shown that physical field simulation results and measured data are basically in consisent by experiment,it is proved multi-physics coupling is an effective method for forecast of noise.

  18. Safety aspects of neutron noise diagnostics and loose parts monitoring in WWER reactors

    International Nuclear Information System (INIS)

    Por, G.

    1997-01-01

    In this paper our aim is to give very short introduction on different types of well selected noise diagnostics methods and then mentioning their occurrence in WWER reactors we analyze what impact they might have to operational safety and for ageing (which also affects on safety of the installations). We do not deny, that one of our main aim is to call the attention of management staff of NPP, which deals with safety, safety culture, maintenance and operation proving, that such methods and system can give not only benefit to economy but also impact on safety of nuclear installations. 14 refs, 6 figs

  19. The Effects of Signal Erosion and Core Genome Reduction on the Identification of Diagnostic Markers

    Directory of Open Access Journals (Sweden)

    Jason W. Sahl

    2016-09-01

    Full Text Available Whole-genome sequence (WGS data are commonly used to design diagnostic targets for the identification of bacterial pathogens. To do this effectively, genomics databases must be comprehensive to identify the strict core genome that is specific to the target pathogen. As additional genomes are analyzed, the core genome size is reduced and there is erosion of the target-specific regions due to commonality with related species, potentially resulting in the identification of false positives and/or false negatives.

  20. observer-based diagnostics and monitoring of vibrations in nuclear reactor core cooling system

    International Nuclear Information System (INIS)

    Siry, S.A K.

    2007-01-01

    analysis and diagnostics of vibration in industrial systems play a significant rule to prevent severe severe damages . drive shaft vibration is a complicated phenomenon composed of two independent forms of vibrations, translational and torsional. translational vibration measurements in case of the reactor core cooling system are introduced. the system under study consists of the three phase induction motor, flywheel, centrifugal pump, and two coupling between motor-flywheel, and flywheel-pump. this system structure is considered to be one where the blades are pegged into the discs fitting into the shafts. a non-linear model to simulate vibration in the reactor core cooling system will be introduced. simulation results of an operating reactor core cooling system using the actual parameters will be presented to validate the accuracy and reliability of the proposed analytical method the accuracy in analyzing the results depends on the system model. the shortcomings of the conventional model will be avoided through the use of that accurate nonlinear model which improve the simulation of the reactor core cooling system

  1. Research and Development Program in Reactor Diagnostics and Monitoring with Neutron Noise Methods. Stages 14 and 15

    International Nuclear Information System (INIS)

    Pazsit, Imre; Wihlstrand, Gustav; Tambouratzis, Tatiana; Jonsson, Anders; Dahl, Berit

    2009-12-01

    This report constitutes Stages 14 and 15 of a long-term research and development program concerning the development of diagnostics and monitoring methods for nuclear reactors. Stage 14 was a full one-year project, whereas Stage 15 consisted of a half-year project. The program executed in Stages 14 and 15 consists of the following three parts: - Study of criticality, neutron kinetics and neutron noise in molten salt reactors (MSR) (Stages 14 and 15); - An overview and introduction to fuzzy logics (Stage 14), and an application to two-phase flow identification (Stage 15) - Preparations for and execution of an IAEA-ICTP workshop on Neutron fluctuations, reactor noise and their applications in nuclear reactors (Stage 14)

  2. Research and Development Program in Reactor Diagnostics and Monitoring with Neutron Noise Methods. Stages 14 and 15

    Energy Technology Data Exchange (ETDEWEB)

    Pazsit, Imre; Wihlstrand, Gustav; Tambouratzis, Tatiana; Jonsson, Anders; Dahl, Berit (Chalmers Univ. of Technology, Dept. of Nuclear Engineering, SE-412 96 Goeteborg (Sweden))

    2009-12-15

    This report constitutes Stages 14 and 15 of a long-term research and development program concerning the development of diagnostics and monitoring methods for nuclear reactors. Stage 14 was a full one-year project, whereas Stage 15 consisted of a half-year project. The program executed in Stages 14 and 15 consists of the following three parts: - Study of criticality, neutron kinetics and neutron noise in molten salt reactors (MSR) (Stages 14 and 15); - An overview and introduction to fuzzy logics (Stage 14), and an application to two-phase flow identification (Stage 15) - Preparations for and execution of an IAEA-ICTP workshop on Neutron fluctuations, reactor noise and their applications in nuclear reactors (Stage 14)

  3. Development and applications of reactor noise analysis at Ontario Hydro`s CANDU reactors

    Energy Technology Data Exchange (ETDEWEB)

    Gloeckler, O [Ontario Hydro, Toronto, ON (Canada); Tulett, M V [Ontario Hydro, Pickering, ON (Canada). Pickering Generating Station

    1996-12-31

    In 1992 a program was initiated to establish reactor noise analysis as a practical tool for plant performance monitoring and system diagnostics in Ontario Hydro`s CANDU reactors. Since then, various CANDU-specific noise analysis applications have been developed and validated. The noise-based statistical techniques are being successfully applied as powerful troubleshooting and diagnostic tools to a wide variety of actual operational I and C problems. The dynamic characteristics of critical plant components, instrumentation and processes are monitored on a regular basis. Recent applications of noise analysis include (1) validating the dynamics of in-core flux detectors (ICFDS) and ion chambers, (2) estimating the prompt fraction ICFDs in noise measurements at full power and in power rundown tests, (3) identifying the cause of excessive signal fluctuations in certain flux detectors, (4) validating the dynamic coupling between liquid zone control signals, (5) detecting and monitoring mechanical vibrations of detector tubes induced by moderator flow, (6) estimating the dynamics and response time of RTD (Resistance Temperature Detector) temperature signals, (7) isolating the cause of RTD signal anomalies, (8) investigating the source of abnormal flow signal behaviour, (9) estimating the overall response time of flow and pressure signals, (10) detecting coolant boiling in fully instrumented fuel channels, (11) monitoring moderator circulation via temperature noise, and (12) predicting the performance of shut-off rods. Some of these applications are performed on an as-needed basis. The noise analysis program, in the Pickering-B station alone, has saved Ontario Hydro millions of dollars during its first three years. The results of the noise analysis program have been also reviewed by the regulator (Atomic Energy Control Board of Canada) with favorable results. The AECB have expressed interest in Ontario Hydro further exploiting the use of noise analysis technology. (author

  4. Calibration of the charge exchange recombination spectroscopy diagnostic for core poloidal rotation velocity measurements on JET

    International Nuclear Information System (INIS)

    Crombe, K.; Andrew, Y.; Giroud, C.; Hawkes, N.C.; Murari, A.; Valisa, M.; Oost, G. van; Zastrow, K.-D.

    2004-01-01

    This article describes recent improvements in the measurement of C 6+ impurity ion poloidal rotation velocities in the core plasma of JET using charge exchange recombination spectroscopy. Two independent techniques are used to provide an accurate line calibration. The first method uses a Perkin-Elmer type 303-306 samarium hollow cathode discharge lamp, with a Sm I line at 528.291 nm close to the C VI line at 529.1 nm. The second method uses the Be II at 527.06 nm and C III at 530.47 nm in the plasma spectrum as two marker lines on either side of the C VI line. Since the viewing chords have both a toroidal and poloidal component, it is important to determine the contribution of the toroidal rotation velocity component separately. The toroidal rotation velocity in the plasma core is measured with an independent charge exchange recombination spectroscopy diagnostic, looking tangentially at the plasma core. The contribution of this velocity along the lines of sight of the poloidal rotation diagnostic has been determined experimentally in L-mode plasmas keeping the poloidal component constant (K. Crombe et al., Proc. 30th EPS Conference, St. Petersburg, Russia, 7-11 July 2003, p. 1.55). The results from these experiments are compared with calculations of the toroidal contribution that take into account the original design parameters of the diagnostic and magnetic geometry of individual shots

  5. Noise diagnostic: An advanced technique in Cuba

    International Nuclear Information System (INIS)

    Aguilar, O.

    1992-01-01

    This paper examines the main steps of the noise analysis technique implementation in our country from 1988. The review identifies two main areas, improvements of Nuclear Power Plant operational surveillance techniques and non-nuclear industrial applications. Also reported are some of the on going researches programs including projects on noise analysis instrumentation developments at the Higher Institute for Nuclear Sciences and Technology

  6. Development of fault diagnostic technique using reactor noise analysis

    International Nuclear Information System (INIS)

    Park, Jin Ho; Kim, J. S.; Oh, I. S.; Ryu, J. S.; Joo, Y. S.; Choi, S.; Yoon, D. B.

    1999-04-01

    The ultimate goal of this project is to establish the analysis technique to diagnose the integrity of reactor internals using reactor noise. The reactor noise analyses techniques for the PWR and CANDU NPP(Nuclear Power Plants) were established by which the dynamic characteristics of reactor internals and SPND instrumentations could be identified, and the noise database corresponding to each plant(both Korean and foreign one) was constructed and compared. Also the change of dynamic characteristics of the Ulchin 1 and 2 reactor internals were simulated under presumed fault conditions. Additionally portable reactor noise analysis system was developed so that real time noise analysis could directly be able to be performed at plant site. The reactor noise analyses techniques developed and the database obtained from the fault simulation, can be used to establish a knowledge based expert system to diagnose the NPP's abnormal conditions. And the portable reactor noise analysis system may be utilized as a substitute for plant IVMS(Internal Vibration Monitoring System). (author)

  7. Development of fault diagnostic technique using reactor noise analysis

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jin Ho; Kim, J. S.; Oh, I. S.; Ryu, J. S.; Joo, Y. S.; Choi, S.; Yoon, D. B

    1999-04-01

    The ultimate goal of this project is to establish the analysis technique to diagnose the integrity of reactor internals using reactor noise. The reactor noise analyses techniques for the PWR and CANDU NPP(Nuclear Power Plants) were established by which the dynamic characteristics of reactor internals and SPND instrumentations could be identified, and the noise database corresponding to each plant(both Korean and foreign one) was constructed and compared. Also the change of dynamic characteristics of the Ulchin 1 and 2 reactor internals were simulated under presumed fault conditions. Additionally portable reactor noise analysis system was developed so that real time noise analysis could directly be able to be performed at plant site. The reactor noise analyses techniques developed and the database obtained from the fault simulation, can be used to establish a knowledge based expert system to diagnose the NPP's abnormal conditions. And the portable reactor noise analysis system may be utilized as a substitute for plant IVMS(Internal Vibration Monitoring System). (author)

  8. Plant diagnostics in power stations

    International Nuclear Information System (INIS)

    Sturm, A.; Doering, D.

    1985-01-01

    The method of noise diagnostics is dealt with as a part of plant diagnostics in nuclear power stations. The following special applications are presented: (1) The modular noise diagnostics system is used for monitoring primary coolant circuits and detecting abnormal processes due to mechanical vibrations, loose parts or leaks. (2) The diagnostics of machines and plants with antifriction bearings is based on bearing vibration measurements. (3) The measurement of the friction moment by means of acoustic emission analysis is used for evaluating the operational state of slide bearings

  9. What is the added value of combined core biopsy and fine needle aspiration in the diagnostic process of renal tumours?

    NARCIS (Netherlands)

    Barwari, K.; Kümmerlin, I.P.E.D.; Ten Kate, F.J.; Algaba, F.; Trias, I.; Wijkstra, H.; Rosette, de la J.J.M.C.H.; Laguna, M.P.

    2013-01-01

    Purpose Non-diagnostic results still hinder the routine use of core biopsy (CB) and fine needle aspiration (FNA) in the diagnostic process of renal tumours. Furthermore, substantial interobserver variability has been reported. We assessed the added value of combining the results of CB and FNA by

  10. What is the added value of combined core biopsy and fine needle aspiration in the diagnostic process of renal tumours?

    NARCIS (Netherlands)

    Barwari, K.; Kummerlin, I. P.; ten Kate, F. J.; Algaba, F.; Trias, I.; Wijkstra, H.; de la Rosette, J. J.; Laguna, P.

    2013-01-01

    Non-diagnostic results still hinder the routine use of core biopsy (CB) and fine needle aspiration (FNA) in the diagnostic process of renal tumours. Furthermore, substantial interobserver variability has been reported. We assessed the added value of combining the results of CB and FNA by five

  11. Factors influencing diagnostic yield of CT-guided percutaneous core needle biopsy for bone lesions

    International Nuclear Information System (INIS)

    Li, Y.; Du, Y.; Luo, T.Y.; Yang, H.F.; Yu, J.H.; Xu, X.X.; Zheng, H.J.; Li, B.

    2014-01-01

    Aim: To evaluate the factors influencing diagnostic yield of computed tomography (CT)-guided percutaneous core needle biopsy (CNB) for bone lesions. Materials and methods: Between September 2005 and July 2011, 162 consecutive CT-guided CNB procedures were performed in 155 patients. The variables analysed were age, sex, lesion location, lesion type, lesion size, specimen size, biopsy needle gauge, and individual radiologist. The factors influencing diagnostic yield of CT-guided percutaneous CNB for bone lesions were determined by multivariate analysis of variables. Results: The diagnostic yield was 81.5%. Diagnostic yield was 89.9% for lytic bone lesions and 48.5% for sclerotic bone lesions (p < 0.001), and 89.2% for lesions ≥3 cm and 73.4% for lesions <3 cm (p = 0.010). The significant factors influencing diagnostic yield of CT-guided percutaneous CNB for bone lesions were lesion type [p < 0.001; odds ratio (OR) for a lytic lesion was approximately 12 times higher than that for a sclerotic lesion; 95% confidence interval (CI): 4.22–34.01], and lesion size (p = 0.012; OR for a lesion size ≥3 cm was about five-times higher than that for a lesion size <3 cm; 95% CI: 1.42–16.71). Conclusion: Lesion type and lesion size are determining factors in diagnostic yield. The higher diagnostic yield is correlated with lytic lesion and lesion size ≥3 cm

  12. Computed-Tomography-Guided Percutaneous Core Needle Biopsies of Suspected Malignant Lymphomas: Impact of Biopsy, Lesion, and Patient Parameters on Diagnostic Yield

    International Nuclear Information System (INIS)

    Hesselmann, V.; Zaehringer, M.; Krug, B.; Wesselmann, C.; Haferkamp, K.; Wickenhauser, C.; Lackner, K.

    2004-01-01

    Purpose: To investigate the diagnostic yield of core needle biopsy in patients with malignant lymphoma. Material and Methods: Computed-tomography-guided core needle biopsies in patients with malignant lymphoma performed in the period 1996 to 2001 were evaluated retrospectively. A biopsy was considered as 'fully diagnostic' if a histological diagnosis, including the histologic subtype in the event of malignant lymphoma, was achieved and the clinical course and CT follow-up of at least 6 months confirmed the biopsy results. A biopsy was regarded as 'partly diagnostic' if histological work-up defined malignant lymphoma but not the histological subtype, and if histological diagnosis bore therapeutic relevance. Diagnostic yield was correlated with features such as size of specimen, location and depth of the target lesion, and experience of the investigator. Results: 45 biopsies were performed in 40 patients. With respect to definite histopathological diagnosis, 31 biopsies (68.9%) were diagnostic and 14 (31.1%) non-diagnostic. In 4 cases (8.8%), biopsies yielded partly diagnostic results, since therapy could be scheduled after biopsy without final sub-classification. Statistical analysis of biopsy parameters revealed that sample sizes were significantly larger in the diagnostic group. Conclusion: CT-guided biopsy can be considered as an alternative for lymphoma diagnosis and should be the first interventional procedure. The most important parameter for diagnostic success is the size of the specimen

  13. Research and development program in reactor diagnostics and monitoring with neutron noise methods. Stage 6. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Pazsit, I.; Demaziere, C.; Avdic, S.; Dahl, B. [Chalmers Univ. of Technology, Goeteborg (Sweden). Dept. of Reactor Physics

    2000-07-15

    by a finite difference scheme, similar to the one used in the previous stage. Actually, a relatively large and involved computational tool was elaborated, containing several modules. In the first module the static, space-dependent group constants are generated, to be used as input by the finite difference dynamic code. These are calculated through CASMO/SIMULATE for a realistic heterogeneous core. The dynamic code then calculates the noise for a number of hypothetical perturbations. The perturbations can be given either as direct changes in the cross-sections, or changes in the temperature of various components (coolant, fuel etc.). In the latter case the temperature fluctuations are converted into cross-section fluctuations by another module. Finally the noise is calculated in two or three dimensions by using the static group constants, the time derivatives, the delayed neutron data and the perturbations data. By a suitable choice of the perturbation, the Green's function can also be calculated, from which the noise induced by other perturbations can be calculated by integration. The model was verified through comparison to analytical calculations. It has been proposed a long time ago that the cross-correlation or coherence between the neutron noise, measured locally in the core, and the core-exit thermocouples can be used to determine the MTC. Such a method would have large advantages over the traditional ones because it would not interfere with the reactor operation. Earlier investigations showed nevertheless that the MTC value, obtained from such investigations, gave a quantitative value for the MTC that was 2 to 5 times lower than the true one. One very likely reason for this deviation lies in the fact that in the evaluation of the noise measurement, it is assumed that the temperature fluctuations, driving the neutron noise, are homogeneously distributed in the core, and that the response of the reactor is point-kinetic. In reality none of these two

  14. On the neutron noise diagnostics of pressurized water reactor control rod vibrations II. Stochastic vibrations

    International Nuclear Information System (INIS)

    Pazsit, I.; Glockler, O.

    1984-01-01

    In an earlier publication, using the theory of neutron fluctuations induced by a vibrating control rod, a complete formal solution of rod vibration diagnostics based on neutron noise measurements was given in terms of Fourier-transformed neutron detector time signals. The suggested procedure was checked in numerical simulation tests where only periodic vibrations could be considered. The procedure and its numerical testing are elaborated for stochastic two-dimensional vibrations. A simple stochastic theory of two-dimensional flow-induced vibrations is given; then the diagnostic method is formulated in the stochastic case, that is, in terms of neutron detector auto- and crosspower spectra. A previously suggested approximate rod localization technique is also formulated in the stochastic case. Applicability of the methods is then investigated in numerical simulation tests, using the proposed model of stochastic two-dimensional vibrations when generating neutron detector spectra that simulate measured data

  15. Approaches to Demonstrating the Reliability and Validity of Core Diagnostic Criteria for Chronic Pain.

    Science.gov (United States)

    Bruehl, Stephen; Ohrbach, Richard; Sharma, Sonia; Widerstrom-Noga, Eva; Dworkin, Robert H; Fillingim, Roger B; Turk, Dennis C

    2016-09-01

    The Analgesic, Anesthetic, and Addiction Clinical Trial Translations, Innovations, Opportunities, and Networks-American Pain Society Pain Taxonomy (AAPT) is designed to be an evidence-based multidimensional chronic pain classification system that will facilitate more comprehensive and consistent chronic pain diagnoses, and thereby enhance research, clinical communication, and ultimately patient care. Core diagnostic criteria (dimension 1) for individual chronic pain conditions included in the initial version of AAPT will be the focus of subsequent empirical research to evaluate and provide evidence for their reliability and validity. Challenges to validating diagnostic criteria in the absence of clear and identifiable pathophysiological mechanisms are described. Based in part on previous experience regarding the development of evidence-based diagnostic criteria for psychiatric disorders, headache, and specific chronic pain conditions (fibromyalgia, complex regional pain syndrome, temporomandibular disorders, pain associated with spinal cord injuries), several potential approaches for documentation of the reliability and validity of the AAPT diagnostic criteria are summarized. The AAPT is designed to be an evidence-based multidimensional chronic pain classification system. Conceptual and methodological issues related to demonstrating the reliability and validity of the proposed AAPT chronic pain diagnostic criteria are discussed. Copyright © 2016 American Pain Society. Published by Elsevier Inc. All rights reserved.

  16. Coupling-induced cooperative behaviour in dynamic ferromagnetic cores in the presence of a noise floor

    International Nuclear Information System (INIS)

    Bulsara, Adi R.; Lindner, John F.; In, Visarath; Kho, Andy; Baglio, Salvatore; Sacco, Vincenzo; Ando, Bruno; Longhini, Patrick; Palacios, Antonio; Rappel, Wouter-Jan

    2006-01-01

    Recently, we have shown the emergence of oscillations in overdamped undriven nonlinear dynamic systems subject to carefully crafted coupling schemes and operating conditions. Here, we summarize experimental results obtained on a system of N=3 coupled ferromagnetic cores, the underpinning of a 'coupled-core fluxgate magnetometer' (CCFM); the oscillatory behaviour is triggered when the coupling constant exceeds a threshold value (bifurcation point), and the oscillation frequency exhibits a characteristic scaling behaviour with the 'separation' of the coupling constant from its threshold value, as well as with an external target DC magnetic flux signal. The oscillations, which can be induced at frequencies ranging from a few Hz to high-kHz, afford a new detection scheme for weak target magnetic signals. We also present the first (numerical) results on the effects of a (Gaussian, exponentially correlated) noise floor on the spectral properties of the system response

  17. Coupling-induced cooperative behaviour in dynamic ferromagnetic cores in the presence of a noise floor

    Energy Technology Data Exchange (ETDEWEB)

    Bulsara, Adi R. [Space and Naval Warfare Systems Center San Diego, Code 2363, 53560 Hull Street, San Diego, CA 92152-5001 (United States)]. E-mail: bulsara@spawar.navy.mil; Lindner, John F. [Physics Department, College of Wooster, Wooster, OH 44691 (United States); In, Visarath [Space and Naval Warfare Systems Center San Diego, Code 2363, 53560 Hull Street, San Diego, CA 92152-5001 (United States); Kho, Andy [Space and Naval Warfare Systems Center San Diego, Code 2363, 53560 Hull Street, San Diego, CA 92152-5001 (United States); Baglio, Salvatore [Dipartimento di Ingegneria Elettrica Elettronica e dei Sistemi, Universita degli Studi di Catania, Viale A. Doria 6, 95125 Catania (Italy); Sacco, Vincenzo [Dipartimento di Ingegneria Elettrica Elettronica e dei Sistemi, Universita degli Studi di Catania, Viale A. Doria 6, 95125 Catania (Italy); Ando, Bruno [Dipartimento di Ingegneria Elettrica Elettronica e dei Sistemi, Universita degli Studi di Catania, Viale A. Doria 6, 95125 Catania (Italy); Longhini, Patrick [Nonlinear Dynamics Group, Department of Mathematics, San Diego State University, San Diego, CA 92182 (United States); Palacios, Antonio [Nonlinear Dynamics Group, Department of Mathematics, San Diego State University, San Diego, CA 92182 (United States); Rappel, Wouter-Jan [Physics Department, University of California at San Diego, La Jolla, CA 929093 (United States)

    2006-04-17

    Recently, we have shown the emergence of oscillations in overdamped undriven nonlinear dynamic systems subject to carefully crafted coupling schemes and operating conditions. Here, we summarize experimental results obtained on a system of N=3 coupled ferromagnetic cores, the underpinning of a 'coupled-core fluxgate magnetometer' (CCFM); the oscillatory behaviour is triggered when the coupling constant exceeds a threshold value (bifurcation point), and the oscillation frequency exhibits a characteristic scaling behaviour with the 'separation' of the coupling constant from its threshold value, as well as with an external target DC magnetic flux signal. The oscillations, which can be induced at frequencies ranging from a few Hz to high-kHz, afford a new detection scheme for weak target magnetic signals. We also present the first (numerical) results on the effects of a (Gaussian, exponentially correlated) noise floor on the spectral properties of the system response.

  18. Experiences with 'on-line' diagnostic instrumentation in nuclear power plants

    International Nuclear Information System (INIS)

    Gopal, R.; Ciaramitaro, W.; Smith, J.R.

    1981-01-01

    Over the past several years, Westinghouse has developed a coordinated system of on-line diagnostic instrumentation for the acquisition and analysis of data for diagnostics and incipient failure detection of critical plant equipment and systems. Primary motivation for this work is to improve Nuclear Steam Supply System (NSSS) availability and maintainability through the detection of malfunctions at their inception. These systems include: 1) Acoustic leak monitoring for detection and location of leaks in the primary system pressure boundary and other piping systems in PWR's; 2) Metal impact monitoring for detection of loose debris in the reactor vessel and steam generators; 3) Nuclear noise monitoring for monitoring core barrel vibration. Summarized in this paper are some of the features of the systems and inplant experience. (author)

  19. Research and development program in reactor diagnostics and monitoring with neutron noise methods. Stage 7. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Pazsit, I.; Demaziere, C.; Arzhanov, V. [Chalmers Univ. of Technology, Goeteborg (Sweden). Department of Reactor Physics; Garis, N.S. [Swedish Nuclear Power Inspectorate, Stockholm (Sweden)

    2001-08-01

    This report constitutes stage 7 of a long-term research and development program concerning the development of diagnostics and monitoring methods for nuclear reactors. A proposal for the continuation of this program in stage 8 is also given at the end of the report. In stage 6, the basic principles of a 3-D fully coupled neutronic/thermal-hydraulic simulator in the frequency domain were presented. The neutronic model relied on the two-group diffusion approximation, whereas the thermal-hydraulic algorithms relied on the so called 'lumped' model. The key element of this simulator was that only the static data were required which could be obtained from the Studsvik Scandpower CASMO-4/TABLES-3/ SIMULATE-3 code package. The simulator was developed with this underlying idea, which means that the calculation of the static fluxes and the eigenvalue were avoided. Depending on what kind of spatial discretization scheme which is used in the noise simulator to calculate the 'leakage' noise, it is not granted that the system remains critical by using the group constants supplied by SIMULATE. Nevertheless, when the system is critical, the balance equations should be fulfilled in all nodes with respect to the discretization scheme used. In concrete terms, the calculation of the static fluxes and eigenvalue can be avoided if the system is brought back to criticality by modifying the cross-sections so that the balance equations are always fulfilled with the chosen spatial discretization scheme. This approach was used in this study with the finite difference scheme. As pointed out in stage 6, the finite difference scheme is relatively inefficient compared to finite elements or nodal methods, but on the other hand it is rather easy to implement. These two more sophisticated schemes are planned to be investigated at a later stage, but for the time being the simulator relying on the finite difference scheme was improved as much as possible so that a 2-D entirely

  20. Noise and vibration analysis system

    International Nuclear Information System (INIS)

    Johnsen, J.R.; Williams, R.L.

    1985-01-01

    The analysis of noise and vibration data from an operating nuclear plant can provide valuable information that can identify and characterize abnormal conditions. Existing plant monitoring equipment, such as loose parts monitoring systems (LPMS) and neutron flux detectors, may be capable of gathering noise data, but may lack the analytical capability to extract useful meanings hidden in the noise. By analyzing neutron noise signals, the structural motion and integrity of core components can be assessed. Computer analysis makes trending of frequency spectra within a fuel cycle and from one cycle to another a practical means of core internals monitoring. The Babcock and Wilcox Noise and Vibration Analysis System (NVAS) is a powerful, compact system that can automatically perform complex data analysis. The system can acquire, process, and store data, then produce report-quality plots of the important parameter. Software to perform neutron noise analysis and loose parts analysis operates on the same hardware package. Since the system is compact, inexpensive, and easy to operate, it allows utilities to perform more frequency analyses without incurring high costs and provides immediate results

  1. Noise analysis based validation of the dynamics of in-core flux detectors and ion chambers used in SDS and RRS systems

    International Nuclear Information System (INIS)

    Gloeckler, O.; Cooke, D.; Tulett, M.V.

    1996-01-01

    The paper concentrates on some of the recent applications of reactor noise analysis in Ontario Hydro's CANDU stations, related to the dynamics of in-core flux detectors (ICFDs) and ion chambers. These applications include (1) detecting anomalies in the dynamics of ICFDs and ion chambers, (2) estimating the effective prompt fractions of ICFDs in power rundown tests and in noise measurement, (3) detecting the mechanical vibration of ICFD instrument tubes induced by moderator flow, (4) detecting the mechanical vibration of fuel channels induced by coolant flow, (5) identifying the cause of excessive signal fluctuations in certain flux detectors, (6) validating the dynamic coupling between liquid zone control signals. Some of these applications are performed on a regular basis. The noise analysis program, in the Pickering-B station alone, has saved Ontario Hydro millions of dollars during its first three years. The results of the noise analysis program have been also reviewed by the AECB with favorable results. The AECB have expressed interest in Ontario Hydro further exploiting the use of noise analysis technology (author)

  2. Power reactor noise measurements in Hungary

    International Nuclear Information System (INIS)

    Pallagi, D.; Horanyi, S.; Hargitai, T.

    1975-01-01

    An outline is given of the history of reactor noise research in Hungary. A brief description is given of studies in the WWR-SM reactor, a modified version of the original WWR-S thermal reactor, for the detection of in-core simulated boiling by analysis of the noise of out-of-core ionization chambers. Coolant velocity measurements by transit time analysis of temperature fluctuations are described. (U.K.)

  3. The simultaneous measurements of core and outer core density fluctuations in L-H transition using CO2 laser collective scattering diagnostic in the EAST superconducting tokamak

    International Nuclear Information System (INIS)

    Cao, G.M.; Li, Y.D.; Zhang, X.D.; Sun, P.J.; Hu, L.Q.; Li, J.G.; Wu, G.J.

    2013-01-01

    The H-mode is the projected basic operation scenario for the ITER tokamak. The turbulence de-correlation by the synergistic effect of zonal flow and equilibrium ExB flow shear is believed to be the reason for L-H transition, however, the detailed physical mechanism has not been identified so far. Tangential multi-channel CO 2 laser collective scattering diagnostic system (mainly k r measurement) was first installed to investigate electron density fluctuations on EAST tokamak. The measurements in a spontaneous dithering L-H transition show that in core plasma (0 < r/a < 0.5) the low-frequency fluctuations strengthen greatly before L-H transition; meanwhile in outer core plasma (0.2 < r/a < 1) the low-frequency fluctuations strengthen slightly. Bispectral analysis reveals that the coupling strength between low- and high-frequency fluctuations in both core and outer core plasma strengthens greatly before the transition, but the latter is greater than the former. The results indicate that the low-frequency fluctuations of the core and outer core plasma play active, but different, roles in the spontaneous L-H transition. (author)

  4. Dual-Energy Computed Tomography Angiography of the Lower Extremity Runoff: Impact of Noise-Optimized Virtual Monochromatic Imaging on Image Quality and Diagnostic Accuracy.

    Science.gov (United States)

    Wichmann, Julian L; Gillott, Matthew R; De Cecco, Carlo N; Mangold, Stefanie; Varga-Szemes, Akos; Yamada, Ricardo; Otani, Katharina; Canstein, Christian; Fuller, Stephen R; Vogl, Thomas J; Todoran, Thomas M; Schoepf, U Joseph

    2016-02-01

    The aim of this study was to evaluate the impact of a noise-optimized virtual monochromatic imaging algorithm (VMI+) on image quality and diagnostic accuracy at dual-energy computed tomography angiography (CTA) of the lower extremity runoff. This retrospective Health Insurance Portability and Accountability Act-compliant study was approved by the local institutional review board. We evaluated dual-energy CTA studies of the lower extremity runoff in 48 patients (16 women; mean age, 63.3 ± 13.8 years) performed on a third-generation dual-source CT system. Images were reconstructed with standard linear blending (F_0.5), VMI+, and traditional monochromatic (VMI) algorithms at 40 to 120 keV in 10-keV intervals. Vascular attenuation and image noise in 18 artery segments were measured; signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Five-point scales were used to subjectively evaluate vascular attenuation and image noise. In a subgroup of 21 patients who underwent additional invasive catheter angiography, diagnostic accuracy for the detection of significant stenosis (≥50% lumen restriction) of F_0.5, 50-keV VMI+, and 60-keV VMI data sets were assessed. Objective image quality metrics were highest in the 40- and 50-keV VMI+ series (SNR: 20.2 ± 10.7 and 19.0 ± 9.5, respectively; CNR: 18.5 ± 10.3 and 16.8 ± 9.1, respectively) and were significantly (all P traditional VMI technique and standard linear blending for evaluation of the lower extremity runoff using dual-energy CTA.

  5. Neutron noise analysis for malfunction diagnosis at sodium cooled reactors

    International Nuclear Information System (INIS)

    Hoppe, P.

    1978-09-01

    For the investigation of the potential use of neutron noise analysis at sodium cooled power reactors, measurements have been performed at the KNK I reactor over a period of 18 month under different operational conditions. The signal fluctuations of the following tranducers have been recorded: In-core and Ex-core neutron detectors, temperature-, flow-, pressure-, vibration- and acoustic sensors. These extensive measurements have been analyzed in the frequency range from 0,001 Hz to 1000 Hz with all currently known methods for the identification of noise sources. The following results have been found: - Neutron noise for f 20 Hz the white detection noise prevails. In the region from 1 Hz to 20 Hz the vibrations of core components contribute to neutron noise. - Neutron noise is influenced by the state of the plant. - The contributions to neutron noise due to the fluctuations of coolant flow and inlet temperature are small compared to those produced by the movements of the control rod initiated by the reactor control system. The quantitatively unidentifiable amount of reactivity fluctuations (0,6 time-dependent thermal bowing of the core. With respect to these results and by calculation of the neutron noise patterns to be expected for the SNR 300, the following possible applications for neutron noise analysis have been found: By means of neutron noise analysis only reactivity fluctuations can be identified and supervised which are produced by time dependent changes of the core geometry. Furthermore neutron noise analysis is well suited for a sensitive detection of control rod vibrations and of local sodium boiling. Finally it can be used for the surveillance of the proper functioning of the reactor control system and of the control rod drive mechanism. (orig./HP) 891 HP [de

  6. Pretreatment axillary ultrasonography and core biopsy in patients with suspected breast cancer: Diagnostic accuracy and impact on management

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Ortega, Maria Jose, E-mail: rserranogan@telefonica.net [Breast Imaging Center, Radiology Department, Hospital Universitario Reina Sofia, Avda. Menendez Pidal s/n, 14004 Cordoba (Spain); Alvarez Benito, Marina, E-mail: marinaalvarezbenito@telefonica.net [Breast Imaging Center, Radiology Department, Hospital Universitario Reina Sofia, Avda. Menendez Pidal s/n, 14004 Cordoba (Spain); Fuentes Vahamonde, Elena, E-mail: elena.fuentes.sspa@juntadeandalucia.es [Pathology Department, Hospital Universitario Reina Sofia, Avda. Menendez Pidal s/n, 14004 Cordoba (Spain); Rioja Torres, Pilar, E-mail: priojat@yahoo.es [Clinical Management Unit, Department of General and Digestive Surgery, Hospital Universitario Reina Sofia, Avda. Menendez Pidal s/n, 14004 Cordoba (Spain); Benitez Velasco, Ana, E-mail: abvelazco@yahoo.es [Nuclear Medicine Department, Hospital Universitario Reina Sofia, Avda. Menendez Pidal s/n, 14004 Cordoba (Spain); Martinez Paredes, Maria, E-mail: mariaparedes@uco.es [Radiology and Physical Medicine Area, University of Cordoba Medical School, Avda. Menendez Pidal s/n, 14004 Cordoba (Spain)

    2011-07-15

    Preoperative diagnosis of axillary metastases in breast cancer patients enables treatment planning. We aimed to evaluate the diagnostic accuracy of axillary ultrasonography and percutaneous biopsy, both alone and in combination, in detecting axillary metastases in patients with breast cancer and to assess the impact of these techniques on the patients' management. Materials and methods: Retrospective study of consecutive patients with suspected breast cancer examined between October 2006 and December 2008. The diagnosis of a primary tumor was histologically confirmed in all patients. All patients underwent axillary ultrasonography and percutaneous core biopsy (14G) of suspicious lymph nodes. We evaluated the morphological characteristics of the lymph nodes by ultrasonography. We calculated the diagnostic accuracy of ultrasonography and of core biopsy, and assessed the impact of these techniques on patients' treatment. Results: We evaluated 675 axillary regions and performed 291 core biopsies of axillary lymph nodes in 662 patients. In 650 patients, breast cancer was histologically confirmed and in 12 patients malignant tumors in other locations were confirmed. The sensitivity and specificity of axillary ultrasonography were 63.2% and 88.7%, respectively. The absence of a fatty hilum within the lymph node was the ultrasonographic finding with the highest positive predictive value for malignancy (93.1%). The sensitivity and specificity of axillary core biopsy were 69.1% and 100%, respectively. Sentinel lymph node biopsy was avoided in 33% of initial candidates and immediate breast reconstruction was undertaken in 35.1% of the patients with mastectomy and negative axillary core biopsy. Conclusions: Ultrasonography and axillary core biopsy enable adequate pretreatment staging in patients with breast cancer and has a positive impact on their management.

  7. Characterization of noise sources in nuclear power reactors

    International Nuclear Information System (INIS)

    Andhill, Gustav

    2004-03-01

    Algorithms for unfolding noise sources in nuclear power reactors are investigated. No preliminary knowledge of the functional form of the space dependence is assumed in contrast to the usual methods. The advantage of this is that the algorithms can be applied to various noise sources and the results can be interpreted without expert knowledge. The results can therefore be directly displayed to the plant operators. The precision will however be lower than that of the traditional methods because of the arbitrariness in the type of the noise source. Two different reactor models are studied. First a simple one-dimensional and homogeneous core is considered. Three methods for finding the noise source from the measured flux noise are investigated here. The first one is based on the inversion of an appropriate pre-calculated noise source-to-measured induced neutron noise transfer function. The second one relies on the use of the measured neutron noise as the solution of the equations giving the neutron noise induced by a given noise source. The advantage of this second method is that the noise source can be determined directly, i.e., without any Inversion of a transfer function. The second method is thus called the direct method. The last method is based on a reconstruction of the noise source by spatial Fourier expansion. The two latter techniques are found usable for different locations of the actual noise source in the 1D core. They are therefore tried on more sophisticated two-dimensional models of cores. The direct method is able both to determine the nature of the noise source and its location in 2D

  8. Characterization of noise sources in nuclear power reactors

    Energy Technology Data Exchange (ETDEWEB)

    Andhill, Gustav

    2004-03-01

    Algorithms for unfolding noise sources in nuclear power reactors are investigated. No preliminary knowledge of the functional form of the space dependence is assumed in contrast to the usual methods. The advantage of this is that the algorithms can be applied to various noise sources and the results can be interpreted without expert knowledge. The results can therefore be directly displayed to the plant operators. The precision will however be lower than that of the traditional methods because of the arbitrariness in the type of the noise source. Two different reactor models are studied. First a simple one-dimensional and homogeneous core is considered. Three methods for finding the noise source from the measured flux noise are investigated here. The first one is based on the inversion of an appropriate pre-calculated noise source-to-measured induced neutron noise transfer function. The second one relies on the use of the measured neutron noise as the solution of the equations giving the neutron noise induced by a given noise source. The advantage of this second method is that the noise source can be determined directly, i.e., without any Inversion of a transfer function. The second method is thus called the direct method. The last method is based on a reconstruction of the noise source by spatial Fourier expansion. The two latter techniques are found usable for different locations of the actual noise source in the 1D core. They are therefore tried on more sophisticated two-dimensional models of cores. The direct method is able both to determine the nature of the noise source and its location in 2D.

  9. Noise investigations in boiling water and pressurized water reactors

    International Nuclear Information System (INIS)

    Kosaly, G.

    1979-08-01

    The paper begins with the general discussion of the neutron noise measured by in-core and ex-core detectors. The theory of BWR noise is surveyed in detail. After the theoretical survey the physical background of the measuring methods applied in the fluctuation analysis of BWRs is discussed. The section on PWR noise discusses the information content of the neutron, pressure and displacement signals about the vibration of the vessel and its internals. (author)

  10. Validation of the dynamics of SDS and RRS flux, flow, pressure and temperature signals using noise analysis technique

    International Nuclear Information System (INIS)

    Glockler, O.; Cooke, D.F.; Tulett, M.V.

    1995-01-01

    In 1992, a program was initiated to establish reactor noise analysis as a practical tool for plant performance monitoring and system diagnostics in Ontario Hydro's CANDU reactors. Since then, various CANDU-specific noise analysis applications have been developed and validated. The noise-based statistical techniques are being successfully applied as powerful troubleshooting and diagnostic tools to a wide variety of actual operational I and C problems. Critical plant components, instrumentation and processes are monitored on a regular basis, and their dynamic characteristics are verified on-power. Recent applications of noise analysis include (1) validating the dynamics of in-core flux detectors (ICFDS) and ion chambers, (2) estimating the prompt fraction ICFDs in noise measurements at full power and in power rundown tests, (3) identifying the cause of excessive signal fluctuations in certain flux detectors, (4) validating the dynamic coupling between liquid zone control signals, (5) detecting and monitoring mechanical vibrations of detector tubes, reactivity devices and fuel channels induced by moderator/coolant flow, (6) estimating the dynamics and response time of RTD temperature signals, (7) isolating the cause of RTD signal anomalies, (8) investigating the source of abnormal flow signal behaviour, (9) estimating the overall response time of flow and pressure signals, (1 0) detecting coolant boiling in fully instrumented fuel channels, (1 1) monitoring moderator circulation via temperature noise, and (12) predicting the performance of shut-off rods. Some of these applications are performed on an as needed basis. The noise analysis program, in the Pickering-B station alone, has saved Ontario Hydro millions of dollars during its first three years. The results of the noise analysis program have been also reviewed by the regulator (Atomic Energy Control Board of Canada) with favorable results. The AECB have expressed interest in Ontario Hydro further exploiting the

  11. Indoor Noise Loading in Residential Prefabricated Buildings

    Science.gov (United States)

    Kraus, Michal; Juhásová Šenitková, Ingrid

    2017-10-01

    Quality on indoor environment is among others also defined by an acoustic comfort and noise emissions. The indoor noise loading in the residential prefabricated buildings is specific problem related to structural design of these buildings. Problems with noise level of sanitary systems are mostly associated with hydraulic shock such as water distribution and sewage drainage. Another very common cause of excessive noise is also flushing the toilet or water fall on enamelled steel (bath or shower). This paper aims to analyse the acoustic properties in the residential prefabricated buildings. Sanitary core of the assessed apartment is in original condition without any alterations. The sanitary core is based on a formica (high-pressure laminate). The study discusses the maximum sound levels in the three assessed rooms for the three different noise sources. The values of maximum noise level are measured for the corridor, bedroom and living room. Sources of noise are common activities relating to the operation of sanitary core - the toilet flush in the toilet, falling water from the shower in the bathroom and the water falling on the bottom of the kitchen sink in the kitchen. Other sources of noise are eliminated or minimized during the experiment. The digital sound level meter Testo 815 is used for measurements. The measured values of maximum sound level LA,max [dB] are adjusted by the correction coefficient. The obtained values are compared with the hygienic limits for day and night period. Night hygienic limit (30 dB) is exceeded in all the rooms for all noise sources. This limit is exceeded from 17 to 73%. The values in the bedroom and the living room meet the daily hygienic limit (40 dB). The daily limit is exceeded only in the corridor. The highest values of noise are identified for the toilet flushing.

  12. A PIV Study of Slotted Air Injection for Jet Noise Reduction

    Science.gov (United States)

    Henderson, Brenda S.; Wernet, Mark P.

    2012-01-01

    Results from acoustic and Particle Image Velocimetry (PIV) measurements are presented for single and dual-stream jets with fluidic injection on the core stream. The fluidic injection nozzles delivered air to the jet through slots on the interior of the nozzle at the nozzle trailing edge. The investigations include subsonic and supersonic jet conditions. Reductions in broadband shock noise and low frequency mixing noise were obtained with the introduction of fluidic injection on single stream jets. Fluidic injection was found to eliminate shock cells, increase jet mixing, and reduce turbulent kinetic energy levels near the end of the potential core. For dual-stream subsonic jets, the introduction of fluidic injection reduced low frequency noise in the peak jet noise direction and enhanced jet mixing. For dual-stream jets with supersonic fan streams and subsonic core streams, the introduction of fluidic injection in the core stream impacted the jet shock cell structure but had little effect on mixing between the core and fan streams.

  13. Regression models of reactor diagnostic signals

    International Nuclear Information System (INIS)

    Vavrin, J.

    1989-01-01

    The application is described of an autoregression model as the simplest regression model of diagnostic signals in experimental analysis of diagnostic systems, in in-service monitoring of normal and anomalous conditions and their diagnostics. The method of diagnostics is described using a regression type diagnostic data base and regression spectral diagnostics. The diagnostics is described of neutron noise signals from anomalous modes in the experimental fuel assembly of a reactor. (author)

  14. Research and Development Program in Reactor Diagnostics and Monitoring with Neutron Noise Methods. Stage 11 and 12. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Sunde, C.; Pazsit, I.; Demaziere, C.; Dahl, O.; Mileshina, L. [Chalmers Univ. of Technology, Goeteborg (Sweden). Dept. of Nuclear Engineering

    2006-06-15

    This report describes the results obtained during Stage 11 and 12 of a long-term research and development program concerning the development of diagnostics and monitoring methods for nuclear reactors. The long-term goals are elaborated in more detail in e.g. the Final Reports of stage 1 and 2 (SKI Report 95:14 and 96:50). Higher order eigenfunctions and eigenvalues of the diffusion equation, describing a static core, have lost their significance when doing calculations in realistic systems, since there are usually made by nodal methods or other direct numerical techniques. However, there are situations when knowledge of the higher order modes is still useful. Such case is the separation of the global and regional flux oscillations in the case of BWR instability. Another case is the investigation of the stability properties of large inhomogeneous cores, which is usually quantified with the so-called eigenvalue separation, ES=1/k{sub 1} - 1/k{sub 0} where k{sub 0} and k{sub 1}, are the fundamental and first higher order eigenvalues, respectively. Numerical codes used for ICMF calculations usually do not have the option of calculating the higher order eigenvalues and eigenfunctions. In idealised systems, these can be calculated with semi-analytical methods. In order to get insight into the characteristics of the higher order eigenmodes of the neutron flux and the adjoint, these were calculated in a reflected homogeneous system with two-group theory. The adjoint eigenmodes are necessary if an orthogonality property needs to be used, such as the separation of the modes from a flux shape which is a sum of several eigenmodes. At the same time, the so-called numerical noise simulator, developed at the Dept., was extended such that it became suitable for the calculation of the higher order eigenmodes, both direct and adjoint ones. This simulator can treat real inhomogeneous cores, with an input deck compatible with that of SIMULATE. The simulator was used to calculate the

  15. Research and Development Program in Reactor Diagnostics and Monitoring with Neutron Noise Methods. Stage 11 and 12. Final report

    International Nuclear Information System (INIS)

    Sunde, C.; Pazsit, I.; Demaziere, C.; Dahl, O.; Mileshina, L.

    2006-06-01

    This report describes the results obtained during Stage 11 and 12 of a long-term research and development program concerning the development of diagnostics and monitoring methods for nuclear reactors. The long-term goals are elaborated in more detail in e.g. the Final Reports of stage 1 and 2 (SKI Report 95:14 and 96:50). Higher order eigenfunctions and eigenvalues of the diffusion equation, describing a static core, have lost their significance when doing calculations in realistic systems, since there are usually made by nodal methods or other direct numerical techniques. However, there are situations when knowledge of the higher order modes is still useful. Such case is the separation of the global and regional flux oscillations in the case of BWR instability. Another case is the investigation of the stability properties of large inhomogeneous cores, which is usually quantified with the so-called eigenvalue separation, ES=1/k 1 - 1/k 0 where k 0 and k 1 , are the fundamental and first higher order eigenvalues, respectively. Numerical codes used for ICMF calculations usually do not have the option of calculating the higher order eigenvalues and eigenfunctions. In idealised systems, these can be calculated with semi-analytical methods. In order to get insight into the characteristics of the higher order eigenmodes of the neutron flux and the adjoint, these were calculated in a reflected homogeneous system with two-group theory. The adjoint eigenmodes are necessary if an orthogonality property needs to be used, such as the separation of the modes from a flux shape which is a sum of several eigenmodes. At the same time, the so-called numerical noise simulator, developed at the Dept., was extended such that it became suitable for the calculation of the higher order eigenmodes, both direct and adjoint ones. This simulator can treat real inhomogeneous cores, with an input deck compatible with that of SIMULATE. The simulator was used to calculate the eigenfunctions and

  16. Power reactor noise

    International Nuclear Information System (INIS)

    Thie, J.A.

    1981-01-01

    This book concentrates on the different types of noise present in power reactors and how the analysis of this noise can be used as a tool for reactor monitoring and diagnostics. Noise analysis is a growing field that offers advantages such as simplicity, low cost, and natural multivariable interactions. A major advantage, continuous and undisturbed monitoring, supplies a means of obtaining early warnings of possible reactor malfunctions thus preventing further complications by alerting operators to a problem - and aiding in the diagnosis of that problem - before it demands major repairs. Following an introductory chapter, the theoretical basis for the various methods of noise analysis is explained, and full chapters are devoted to the fundamentals of statistics for time-domain analysis and Fourier series and related topics for frequency-domain analysis. General experimental techniques and associated theoretical considerations are reviewed, leading to discussion of practical applications in the latter half of the book. Besides chapters giving examples of neutron noise and acoustical noise, chapters are also devoted to extensive examples from pressurized water reactor and boiling water reactor power plants

  17. Representation of neutron noise data using neural networks

    International Nuclear Information System (INIS)

    Korsah, K.; Damiano, B.; Wood, R.T.

    1992-01-01

    This paper describes a neural network-based method of representing neutron noise spectra using a model developed at the Oak Ridge National Laboratory (ORNL). The backpropagation neural network learned to represent neutron noise data in terms of four descriptors, and the network response matched calculated values to within 3.5 percent. These preliminary results are encouraging, and further research is directed towards the application of neural networks in a diagnostics system for the identification of the causes of changes in structural spectral resonances. This work is part of our current investigation of advanced technologies such as expert systems and neural networks for neutron noise data reduction, analysis, and interpretation. The objective is to improve the state-of-the-art of noise analysis as a diagnostic tool for nuclear power plants and other mechanical systems

  18. Utility of core biopsy with concurrent ROSE FNA in the diagnosis of pancreatic tumor-does the biopsy add any diagnostic benefit?

    Science.gov (United States)

    Yan, Lei; Ikemura, Kenji; Park, Ji-Weon

    2018-02-01

    Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) and endoscopic ultrasound-guided core-needle biopsy (EUS-CNB) are widely used for diagnosis of pancreatic tumors. The aim of our study was to compare the diagnostic performance of ROSE EUS-FNA and EUS-CNB for diagnosis of pancreatic malignancy during the same EUS. Patients who underwent both FNA and CNB during the same EUS for pancreatic solid lesion were reviewed retrospectively. Sample adequacy, diagnostic yield (defined as percentage of definitive diagnosis), sensitivity and specificity for malignancy were compared between FNA and CNB. A total of 48 patients with solid pancreatic lesions were evaluated. The proportions of adequate samples were 48/48 (100%) for FNA and 45/48 (93.7%) for core biopsy (P = .24). The diagnostic yield was 42/48 (87.5%) and 33/48 (68.7%) for FNA and CNB respectively (P = .046). The incremental increase in diagnostic yield by combining both methods was 2/48 (4%). The diagnostic yield for malignancy was 30/32 (93.7%) for FNA and 23/32 (71.8%) for CNB (P = .043). The sensitivity for the diagnosis of malignancy for FNA and CNB were 90.6% and 69%, respectively (P = .045). The specificity was 100% for both methods. The sensitivity for diagnosing malignancy increased to 93.8% when the two methods were combined. The difference in diagnostic yield was not associated with lesion size or location. EUS-guided FNA is a superior method of assessing solid pancreatic lesion and pancreatic malignancy with better diagnostic yield and higher sensitivity than EUS-CNB. © 2017 Wiley Periodicals, Inc.

  19. Dynamic behaviour and neutron noise in molten salt reactors with circulating perturbations

    Energy Technology Data Exchange (ETDEWEB)

    Pazsit, I.; Dykin, V. [Chalmers Univ. of Tech., Nuclear Engineering, Goteborg (Sweden)

    2014-07-01

    This paper concerns the calculation of the neutron noise induced in Molten Salt Reactors (MSR) by the random fluctuations in space and time of the molten fuel cross sections which travel together with the fuel and pass the core region. The effect of such fluctuations was already discussed in several publications. The novelty of the present paper is that it takes into account that in addition to the delayed neutron precursors, also the cross section perturbations themselves, whose passing through the core induces the in-core neutron noise, return to the core inlet via the external loop from the core exit. The corresponding theory is developed, and some quantitative investigations are made of the characteristics of the noise, which can be attributed to the recirculation of the perturbation to the core. It is shown that the effect of the returning of the perturbations, even though it is also associated with a temporal decay, has a much stronger effect on the neutron noise spectra than that of the recirculation of the delayed neutron precursors. (author)

  20. Dynamic behaviour and neutron noise in molten salt reactors with circulating perturbations

    International Nuclear Information System (INIS)

    Pazsit, I.; Dykin, V.

    2014-01-01

    This paper concerns the calculation of the neutron noise induced in Molten Salt Reactors (MSR) by the random fluctuations in space and time of the molten fuel cross sections which travel together with the fuel and pass the core region. The effect of such fluctuations was already discussed in several publications. The novelty of the present paper is that it takes into account that in addition to the delayed neutron precursors, also the cross section perturbations themselves, whose passing through the core induces the in-core neutron noise, return to the core inlet via the external loop from the core exit. The corresponding theory is developed, and some quantitative investigations are made of the characteristics of the noise, which can be attributed to the recirculation of the perturbation to the core. It is shown that the effect of the returning of the perturbations, even though it is also associated with a temporal decay, has a much stronger effect on the neutron noise spectra than that of the recirculation of the delayed neutron precursors. (author)

  1. Experience with diagnostic instrumentation in nuclear power plants

    International Nuclear Information System (INIS)

    Gopal, R.; Ciaramitaro, W.

    1977-01-01

    Over the past several years, Westinghouse has developed a coordinated system of on-line diagnostic instrumentation for the acquisition and analysis of data for diagnostics and incipient failure detection of critical plant equipment and systems. Primary motivation for this work is to improve NSSS availability and Maintainability through the detection of malfunctions at their inception. These systems encompass the following areas: (1) Vibration Monitoring System for detection of changes in vibrational characteristics of the major components of Nuclear Steam Supply System (NSSS) and Balance of Plant (BOP); (2) Acoustic Monitoring System for detection and location of leaks in the primary system pressure boundary and other piping systems in PWRs; (3) Metal Impact Monitoring for detection of loose debris in the reactor vessel and steam generators; (4) Nuclear Noise Monitoring System for monitoring core barrel vibration; (5) Sensor Response Time Measurement System for detecting any degradation of process sensors; and (6) Transit Time Flow Meter for determining primary coolant flow rate. Summarized in this paper are some of the features of the systems and in-plant experience. These experiences demonstrate that diagnostic systems in combination with analytical and laboratory work for data interpretation do improve plant availability. (author)

  2. CT-guided core needle biopsy of pleural lesions: Evaluating diagnostic yield and associated complications

    International Nuclear Information System (INIS)

    Niu, Xiang Ke; Bhetuwal, Anup; Yang, Han Feng

    2015-01-01

    The purpose of this study was to retrospectively evaluate the diagnostic accuracy and complications of CT-guided core needle biopsy (CT-guided CNB) of pleural lesion and the possible effects of influencing factors. From September 2007 to June 2013, 88 consecutive patients (60 men and 28 women; mean [+/- standard deviation] age, 51.1 +/- 14.4 years; range, 19-78 years) underwent CT-guided CNB, which was performed by two experienced chest radiologists in our medical center. Out of 88 cases, 56 (63%) were diagnosed as malignant, 28 (31%) as benign and 4 (5%) as indeterminate for CNB of pleural lesions. The final diagnosis was confirmed by either histopathological diagnosis or clinical follow-up. The diagnostic accuracy, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and complication rates were statistically evaluated. Influencing factors (patient age, sex, lesion size, pleural-puncture angle, patient position, pleural effusion, and number of pleural punctures) were assessed for their effect on accuracy of CT-guided CNB using univariate and subsequent multivariate analysis. Diagnostic accuracy, sensitivity, specificity, PPV, and NPV were 89.2%, 86.1%, 100%, 100%, and 67.8%, respectively. The influencing factors had no significant effect in altering diagnostic accuracy. As far as complications were concerned, occurrence of pneumothorax was observed in 14 (16%) out of 88 patients. Multivariate analysis revealed lesion size/pleural thickening as a significant risk factor (odds ratio [OR]: 8.744, p = 0.005) for occurrence of pneumothorax. Moreover, presence of pleural effusion was noted as a significant protective factor (OR: 0.171, p = 0.037) for pneumothorax. CT-guided CNB of pleural lesion is a safe procedure with high diagnostic yield and low risk of significant complications.

  3. CT-guided core needle biopsy of pleural lesions: Evaluating diagnostic yield and associated complications

    Energy Technology Data Exchange (ETDEWEB)

    Niu, Xiang Ke [Dept. of Radiology, Affiliated Hospital of Chengdu University, Chengdu (China); Bhetuwal, Anup; Yang, Han Feng [Dept. of Radiology, Sichuan Key Laboratory of Medical Imaging, Affiliated Hospital of North Sichuan Medical College, Nanchong (China)

    2015-02-15

    The purpose of this study was to retrospectively evaluate the diagnostic accuracy and complications of CT-guided core needle biopsy (CT-guided CNB) of pleural lesion and the possible effects of influencing factors. From September 2007 to June 2013, 88 consecutive patients (60 men and 28 women; mean [+/- standard deviation] age, 51.1 +/- 14.4 years; range, 19-78 years) underwent CT-guided CNB, which was performed by two experienced chest radiologists in our medical center. Out of 88 cases, 56 (63%) were diagnosed as malignant, 28 (31%) as benign and 4 (5%) as indeterminate for CNB of pleural lesions. The final diagnosis was confirmed by either histopathological diagnosis or clinical follow-up. The diagnostic accuracy, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and complication rates were statistically evaluated. Influencing factors (patient age, sex, lesion size, pleural-puncture angle, patient position, pleural effusion, and number of pleural punctures) were assessed for their effect on accuracy of CT-guided CNB using univariate and subsequent multivariate analysis. Diagnostic accuracy, sensitivity, specificity, PPV, and NPV were 89.2%, 86.1%, 100%, 100%, and 67.8%, respectively. The influencing factors had no significant effect in altering diagnostic accuracy. As far as complications were concerned, occurrence of pneumothorax was observed in 14 (16%) out of 88 patients. Multivariate analysis revealed lesion size/pleural thickening as a significant risk factor (odds ratio [OR]: 8.744, p = 0.005) for occurrence of pneumothorax. Moreover, presence of pleural effusion was noted as a significant protective factor (OR: 0.171, p = 0.037) for pneumothorax. CT-guided CNB of pleural lesion is a safe procedure with high diagnostic yield and low risk of significant complications.

  4. Poultry Plant Noise Control

    Science.gov (United States)

    1982-01-01

    A demonstration conducted last winter at the Tip Top Poultry Plant intended to show poultry plant managers from all over the U.S. potential solutions to the problem of plant noise. Plastic covers used over sound absorbing materials need to meet cleanability requirements, high- pressure water cleaning and other harsh maintenance procedures peculiar to the poultry processing industry. For the demonstration, Fiber Flex, Inc. manufactured and donated 750 noise panels; Owens-Corning Fiberglas Corporation donated the fiberglas cores; and the cover material was purchased from Howe and Bainbridge. The Engineering Experiment Station (EES) conducted before and after noise surveys and is evaluating the effect of noise reduction on turnover and productivity in the demonstration plant. EES plans to conduct a noise abatement workshop and update a handbook to help poultry processors with noise problems. EES study and demonstration may be applicable to other food processing plants where similar sanitary constraints exist.

  5. Diagnostic feasibility and safety of CT-guided core biopsy for lung nodules less than or equal to 8 mm. A single-institution experience

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Ying-Yueh [Taipei Veterans General Hospital, Department of Radiology, Taipei (China); Chen, Chun-Ku [Taipei Veterans General Hospital, Department of Radiology, Taipei (China); National Yang-Ming University, School of Medicine, Taipei (China); National Yang-Ming University, Institute of Clinical Medicine, Taipei (China); Yeh, Yi-Chen [National Yang-Ming University, School of Medicine, Taipei (China); Taipei Veterans General Hospital, Department of Pathology and Laboratory Medicine, Taipei (China); Wu, Mei-Han [Taipei Veterans General Hospital, Department of Radiology, Taipei (China); National Yang-Ming University, School of Medicine, Taipei (China)

    2018-02-15

    This retrospective study evaluated the diagnostic yield and safety of CT-guided core biopsy of pulmonary nodules ≤8 mm. We determined the diagnostic yield and safety profile of CT-guided lung biopsies for 125 pulmonary nodules ≤8 mm. Pathological diagnoses were made by a combination of histopathological examination and imprint cytology. Results were compared with biopsy results for 134 pulmonary nodules >8 and ≤10 mm. Final diagnoses were established in 94 nodules ≤8 mm. The sensitivity, specificity and diagnostic accuracy of CT-guided core biopsy for nodules ≤8 mm were 87.1 % (61/70 nodules), 100 % (24/24) and 90.4 % (85/94), respectively. Diagnostic failure rates were comparable for nodules ≤8 mm and nodules >8 mm and ≤10 mm (9/94, 9.6 % and 7/111, 6.3 %, respectively, P=0.385). The rate of tube thoracostomy for nodules ≤8 mm was comparable to that for nodules >8 and ≤10 mm (1.6 % vs. 0.7 %, P=0.611). Nodules ≤6 mm had a higher non-diagnostic result rate of 15.4 % (6/39) than did nodules >8 and ≤10 mm (3.7 %, 5/134, P=0.017). CT-guided pulmonary biopsy is feasible for lung nodules ≤8 mm, especially those >6 mm, and has an acceptable diagnostic yield and safety profile. (orig.)

  6. Faraday-effect polarimeter diagnostic for internal magnetic field fluctuation measurements in DIII-D.

    Science.gov (United States)

    Chen, J; Ding, W X; Brower, D L; Finkenthal, D; Muscatello, C; Taussig, D; Boivin, R

    2016-11-01

    Motivated by the need to measure fast equilibrium temporal dynamics, non-axisymmetric structures, and core magnetic fluctuations (coherent and broadband), a three-chord Faraday-effect polarimeter-interferometer system with fast time response and high phase resolution has recently been installed on the DIII-D tokamak. A novel detection scheme utilizing two probe beams and two detectors for each chord results in reduced phase noise and increased time response [δb ∼ 1G with up to 3 MHz bandwidth]. First measurement results were obtained during the recent DIII-D experimental campaign. Simultaneous Faraday and density measurements have been successfully demonstrated and high-frequency, up to 100 kHz, Faraday-effect perturbations have been observed. Preliminary comparisons with EFIT are used to validate diagnostic performance. Principle of the diagnostic and first experimental results is presented.

  7. Faraday-effect polarimeter diagnostic for internal magnetic field fluctuation measurements in DIII-D

    International Nuclear Information System (INIS)

    Chen, J.; Ding, W. X.; Brower, D. L.; Finkenthal, D.; Muscatello, C.; Taussig, D.; Boivin, R.

    2016-01-01

    Motivated by the need to measure fast equilibrium temporal dynamics, non-axisymmetric structures, and core magnetic fluctuations (coherent and broadband), a three-chord Faraday-effect polarimeter-interferometer system with fast time response and high phase resolution has recently been installed on the DIII-D tokamak. A novel detection scheme utilizing two probe beams and two detectors for each chord results in reduced phase noise and increased time response [δb ∼ 1G with up to 3 MHz bandwidth]. First measurement results were obtained during the recent DIII-D experimental campaign. Simultaneous Faraday and density measurements have been successfully demonstrated and high-frequency, up to 100 kHz, Faraday-effect perturbations have been observed. Preliminary comparisons with EFIT are used to validate diagnostic performance. Principle of the diagnostic and first experimental results is presented.

  8. Research and Development Program in Reactor Diagnostics and Monitoring with Neutron Noise Methods. Stage 10. Final Report

    International Nuclear Information System (INIS)

    Demaziere, C.; Pazsit, I.; Sunde, S.; Wright, J.

    2004-12-01

    This report constitutes Stage 10 of a long-term research and development program concerning the development of diagnostics and monitoring methods for nuclear reactors. The program executed in Stage 10 consists of three parts and the work performed in each part is summarized below. A so-called 2-D 2-group neutron noise simulator was previously developed at the Department of Reactor Physics. This simulator is able to calculate the space-dependence of the neutron noise induced by localised or spatially-distributed absorbers of variable strength or by vibrating absorbers. These calculations are performed in the 2-group diffusion approximation and can treat an arbitrary heterogeneous 2-D system. The goal of the present investigation is to use the simulator for unfolding purposes, i.e. to reconstruct the noise source from the detector readings. This task is particularly challenging since the number of detectors available in a commercial PWR can be very low. In this study, five detectors are assumed to be present and evenly distributed in the core. Furthermore, only localised absorbers of variable strength are considered as perturbations. Numerical simulations were first carried out to verify that the space-dependent local and global components of the neutron noise were overwhelmingly large compared to the point-kinetic term of the neutron noise whose spatial structure does not depend on the position of the perturbation. The significance of the space-dependent global component is that its relaxation length is large enough, so that several neutron detectors can monitor it. Therefore, the neutron noise induced at the position of the detectors is itself a function of the position of the perturbation. Unfolding procedures could thus be considered. Prior to performing any unfolding, the type of the noise source has to be determined, since the algorithms developed in this report are based on the assumption of an absorber of variable strength. Such a noise source can also be

  9. A multi-group neutron noise simulator for fast reactors

    International Nuclear Information System (INIS)

    Tran, Hoai Nam; Zylbersztejn, Florian; Demazière, Christophe; Jammes, Christian; Filliatre, Philippe

    2013-01-01

    Highlights: • The development of a neutron noise simulator for fast reactors. • The noise equation is solved fully in a frequency-domain. • A good agreement with ERANOS on the static calculations. • Noise calculations induced by a localized perturbation of absorption cross section. - Abstract: A neutron noise simulator has been developed for fast reactors based on diffusion theory with multi-energy groups and several groups of delayed neutron precursors. The tool is expected to be applicable for core monitoring of fast reactors and also for other reactor types with hexagonal fuel assemblies. The noise sources are modeled through small stationary fluctuations of macroscopic cross sections, and the induced first order noise is solved fully in the frequency domain. Numerical algorithms are implemented for solving both the static and noise equations using finite differences for spatial discretization, where a hexagonal assembly is radially divided into finer triangular meshes. A coarse mesh finite difference (CMFD) acceleration has been used for accelerating the convergence of both the static and noise calculations. Numerical calculations have been performed for the ESFR core with 33 energy groups and 8 groups of delayed neutron precursors using the cross section data generated by the ERANOS code. The results of the static state have been compared with those obtained using ERANOS. The results show an adequate agreement between the two calculations. Noise calculations for the ESFR core have also been performed and demonstrated with an assumption of the perturbation of the absorption cross section located at the central fuel ring

  10. Research and development program in reactor diagnostics and monitoring with neutron noise methods. Stage 7. Final report

    International Nuclear Information System (INIS)

    Pazsit, I.; Demaziere, C.; Arzhanov, V.

    2001-08-01

    This report constitutes stage 7 of a long-term research and development program concerning the development of diagnostics and monitoring methods for nuclear reactors. A proposal for the continuation of this program in stage 8 is also given at the end of the report. In stage 6, the basic principles of a 3-D fully coupled neutronic/thermal-hydraulic simulator in the frequency domain were presented. The neutronic model relied on the two-group diffusion approximation, whereas the thermal-hydraulic algorithms relied on the so called 'lumped' model. The key element of this simulator was that only the static data were required which could be obtained from the Studsvik Scandpower CASMO-4/TABLES-3/ SIMULATE-3 code package. The simulator was developed with this underlying idea, which means that the calculation of the static fluxes and the eigenvalue were avoided. Depending on what kind of spatial discretization scheme which is used in the noise simulator to calculate the 'leakage' noise, it is not granted that the system remains critical by using the group constants supplied by SIMULATE. Nevertheless, when the system is critical, the balance equations should be fulfilled in all nodes with respect to the discretization scheme used. In concrete terms, the calculation of the static fluxes and eigenvalue can be avoided if the system is brought back to criticality by modifying the cross-sections so that the balance equations are always fulfilled with the chosen spatial discretization scheme. This approach was used in this study with the finite difference scheme. As pointed out in stage 6, the finite difference scheme is relatively inefficient compared to finite elements or nodal methods, but on the other hand it is rather easy to implement. These two more sophisticated schemes are planned to be investigated at a later stage, but for the time being the simulator relying on the finite difference scheme was improved as much as possible so that a 2-D entirely neutronic model could be

  11. Thyroid nodules with isolated macrocalcification: Malignancy and diagnostic efficacy of fine-needle aspiration and core needle biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Na, Dong Gyu; Kim, Dae Sik; Kim, Soo Jin [Dept. of Radiology, Human Medical Imaging and Intervention Center, Seoul (Korea, Republic of); Ryoo, Jae Wook [Dept. of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Jung, So Lyung [Dept. of Radiology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of)

    2016-07-15

    This study was performed to determine the malignancy risk of thyroid nodules with isolated macrocalcification and to evaluate the diagnostic efficacy of fine-needle aspiration (FNA) and core needle biopsy (CNB). From May 2008 to December 2014, a total of 44 patients with isolated macrocalcifications were enrolled from 4,081 consecutive patients who underwent FNA or CNB at a single institution. We assessed the malignancy risk of nodules with isolated macrocalcification. We compared the diagnostic results between FNA and CNB, and the diagnostic efficacy of each procedure was evaluated by the rate of inconclusive results. We compared the diagnostic performance for malignancy between FNA and CNB with a criterion of malignant or atypia/follicular lesion of undetermined significance (indeterminate) diagnostic results. We investigated whether the ultrasonographic feature of isolated macrocalcification was predictive of malignancy. The malignancy risk of nodules with isolated macrocalcification was 16.1% in 31 nodules with final diagnoses and 11.4% in all nodules. CNB demonstrated a significantly lower rate of nondiagnostic and inconclusive results than FNA (7.7% vs. 53.8%, P=0.002 and 15.4% vs. 57.7%, P=0.003, respectively) in 26 nodules that underwent both FNA and CNB. CNB showed a marginally higher diagnostic performance for identifying malignancy than FNA (P=0.067). The ultrasonographic features of the anterior margin of isolated macrocalcification were not predictive of malignancy (P>0.999). Thyroid nodules with isolated macrocalcification had a low to intermediate malignancy risk and should not be considered benign nodules. CNB showed a higher diagnostic efficacy than FNA in these nodules.

  12. Thyroid nodules with isolated macrocalcification: Malignancy and diagnostic efficacy of fine-needle aspiration and core needle biopsy

    International Nuclear Information System (INIS)

    Na, Dong Gyu; Kim, Dae Sik; Kim, Soo Jin; Ryoo, Jae Wook; Jung, So Lyung

    2016-01-01

    This study was performed to determine the malignancy risk of thyroid nodules with isolated macrocalcification and to evaluate the diagnostic efficacy of fine-needle aspiration (FNA) and core needle biopsy (CNB). From May 2008 to December 2014, a total of 44 patients with isolated macrocalcifications were enrolled from 4,081 consecutive patients who underwent FNA or CNB at a single institution. We assessed the malignancy risk of nodules with isolated macrocalcification. We compared the diagnostic results between FNA and CNB, and the diagnostic efficacy of each procedure was evaluated by the rate of inconclusive results. We compared the diagnostic performance for malignancy between FNA and CNB with a criterion of malignant or atypia/follicular lesion of undetermined significance (indeterminate) diagnostic results. We investigated whether the ultrasonographic feature of isolated macrocalcification was predictive of malignancy. The malignancy risk of nodules with isolated macrocalcification was 16.1% in 31 nodules with final diagnoses and 11.4% in all nodules. CNB demonstrated a significantly lower rate of nondiagnostic and inconclusive results than FNA (7.7% vs. 53.8%, P=0.002 and 15.4% vs. 57.7%, P=0.003, respectively) in 26 nodules that underwent both FNA and CNB. CNB showed a marginally higher diagnostic performance for identifying malignancy than FNA (P=0.067). The ultrasonographic features of the anterior margin of isolated macrocalcification were not predictive of malignancy (P>0.999). Thyroid nodules with isolated macrocalcification had a low to intermediate malignancy risk and should not be considered benign nodules. CNB showed a higher diagnostic efficacy than FNA in these nodules

  13. Core biopsies of the breast: Diagnostic pitfalls

    Directory of Open Access Journals (Sweden)

    Megha Joshi

    2011-01-01

    Full Text Available The incidence of breast cancer is increasing worldwide. In this review article, the authors compare and contrast the incidence of breast cancer, and the inherent differences in the United States (US and India in screening techniques used for diagnosing breast cancer. In spite of these differences, core biopsies of the breast are common for diagnosis of breast cancer in both countries. The authors describe "Best Practices" in the reporting and processing of core biopsies and in the analysis of estrogen receptor (ER, progesterone receptor (PR, and human epidermal growth factor Receptor 2 (Her2/neu. The pitfalls in the diagnosis of fibroepithelial lesions of the breast on core biopsy are discussed, as also the significance of pseudoangiomatous stromal hyperplasia of the breast (PASH is discussed in core biopsy. In this review, the management and diagnosis of flat epithelial atypia and radiation atypia are elaborated and the use of immunohistochemistry (IHC in papillary lesions, phyllodes tumor, and complex sclerosing lesions (radial scars is illustrated. Rarer lesions such as mucinous and histiocytoid carcinoma are also discussed.

  14. Measurements and Predictions of the Noise from Three-Stream Jets

    Science.gov (United States)

    Henderson, Brenda S.; Leib, Stewart J.; Wernet, Mark P.

    2015-01-01

    An experimental and numerical investigation of the noise produced by high-subsonic and supersonic three-stream jets was conducted. The exhaust system consisted of externally-mixed-convergent nozzles and an external plug. Bypass- and tertiary-to-core area ratios between 1.0 and 2.5, and 0.4 and 1.0, respectively, were studied. Axisymmetric and offset tertiary nozzles were investigated for heated and unheated conditions. For axisymmetric configurations, the addition of the third stream was found to reduce peak- and high-frequency acoustic levels in the peak-jet-noise direction, with greater reductions at the lower bypass-to-core area ratios. For the offset configurations, an offset duct was found to decrease acoustic levels on the thick side of the tertiary nozzle relative to those produced by the simulated two-stream jet with up to 8 dB mid-frequency noise reduction at large angles to the jet inlet axis. Noise reduction in the peak-jet-noise direction was greater for supersonic core speeds than for subsonic core speeds. The addition of a tertiary nozzle insert used to divert the third-stream jet to one side of the nozzle system provided no noise reduction. Noise predictions are presented for selected cases using a method based on an acoustic analogy with mean flow interaction effects accounted for using a Green's function, computed in terms of its coupled azimuthal modes for the offset cases, and a source model previously used for round and rectangular jets. Comparisons of the prediction results with data show that the noise model predicts the observed increase in low-frequency noise with the introduction of a third, axisymmetric stream, but not the high-frequency reduction. For an offset third stream, the model predicts the observed trend of decreased sound levels on the thick side of the jet compared with the thin side, but the predicted azimuthal variations are much less than those seen in the data. Also, the shift of the spectral peak to lower frequencies with

  15. Coupled-core fluxgate magnetometer: Novel configuration scheme and the effects of a noise-contaminated external signal

    International Nuclear Information System (INIS)

    Palacios, Antonio; Aven, John; In, Visarath; Longhini, Patrick; Kho, Andy; Neff, Joseph D.; Bulsara, Adi

    2007-01-01

    Recent theoretical and experimental work has shown that unidirectional coupling can induce oscillations in overdamped and undriven nonlinear dynamical systems that are non-oscillatory when uncoupled; in turn, this has been shown to lead to new mechanisms for weak (compared to the energy barrier height) signal detection and amplification. The potential applications include fluxgate magnetometers, electric field sensors, and arrays of Superconducting Quantum Interference Device (SQUID) rings. In the particular case of the fluxgate magnetometer, we have developed a ''coupled-core fluxgate magnetometer'' (CCFM); this device has been realized in the laboratory and its dynamics used to quantify many properties that are generic to this class of systems and coupling. The CCFM operation is underpinned by the emergent oscillatory behavior in a unidirectionally coupled ring of wound ferromagnetic cores, each of which can be treated as an overdamped bistable dynamic system when uncoupled. In particular, one can determine the regimes of existence and stability of the (coupling-induced) oscillations, and the scaling behavior of the oscillation frequency. More recently, we studied the effects of a (Gaussian) magnetic noise floor on a CCFM system realized with N=3 coupled ferromagnetic cores. In this Letter, we first introduce a variation on the basic CCFM configuration that affords a path to enhanced device sensitivity, particularly for N>=3 coupled elements. We then analyze the response of the basic CCFM configuration as well as the new setup to a dc target signal that has a small noisy component (or ''contamination'')

  16. Thermal and mechanical design of the plasma core CXRS diagnostics for the fusion reactor ITER; Thermische und mechanische Auslegung der Plasma Core CXRS Diagnostik des ITER Kernfusionsreaktors

    Energy Technology Data Exchange (ETDEWEB)

    Greza, H. [WTI Wissenschaftlich-Technische Ingenieurberatung GmbH, Juelich (Germany); Neubauer, O.; Wolters, J. [Forschungszentrum Juelich GmbH (Germany)

    2009-07-01

    In the frame of the research project ITER (international thermonuclear experimental reactor) the plasma state is monitored using the plasma core diagnostics CXRS (charge exchange recombination spectroscopy).The authors describe the thermal and mechanical design of the first mirror of the CXRS diagnostics. The components of the first mirror are exposed to high heat and neutron irradiation. The surface temperature will be 300 to 400 deg C. The misalignment tolerance is plus or minus 0.1 degree. The maximum mechanical stresses in the mirror have to be minimized. The design calculations use the finite element code ANSYS. The results indicate that the heat input from the plasma can be removed by the coolant flow. Further calculation shave to concern the brazed joints between mirror and cooling block.

  17. Thermal and mechanical design of the plasma core CXRS diagnostics for the fusion reactor ITER; Thermische und mechanische Auslegung der Plasma Core CXRS Diagnostik des ITER Kernfusionsreaktors

    Energy Technology Data Exchange (ETDEWEB)

    Greza, H.; Knauff, R. [Wissenschaftlich-Technische Ingenieurberatung GmbH (WTI), Juelich (Germany); Neubauer, O.; Wolters, J.; Offermanns, G.; Biel, W. [Forschungszentrum Juelich GmbH (Germany)

    2011-07-01

    In the frame of the research project ITER (international thermonuclear experimental reactor) the plasma state is monitored using the plasma core diagnostics CXRS (charge exchange recombination spectroscopy).The authors describe the thermal and mechanical design of the first mirror of the CXRS diagnostics. The components of the first mirror are exposed to high heat and neutron irradiation. The surface temperature will be 300 to 400 deg C. The misalignment tolerance is plus or minus 0.1 degree. The maximum mechanical stresses in the mirror have to be minimized. The design calculations use the finite element code ANSYS. The results indicate that the heat input from the plasma can be removed by the coolant flow. Further calculation shave to concern the brazed joints between mirror and cooling block.

  18. Diagnostic system and diagnostic experiences at the Paks Nuclear Power Plant

    International Nuclear Information System (INIS)

    Katona, Tamas

    1986-01-01

    The major functions of the diagnostic system of the first two units of the Paks Nuclear Power Plant are as follows: monitoring the mechanical integrity of the reactor and the primary coolant circuit by means of vibration diagnostics; leakage detection of the primary coolant circuit by means of high frequency sonic analysis; loose parts monitoring based on the analysis of high frequency signals of acceleration detectors; and monitoring the vibration state of the turbines and rotary machines by the latter method or by a procedure based on the detection of mechanical vibrations. Up-to-date vibration diagnostics is based on the information supplied by either acceleration detectors or pressure fluctuation detectors, or in-core and ex-core neutron detectors. (V.N.)

  19. Tuned Chamber Core Panel Acoustic Test Results

    Science.gov (United States)

    Schiller, Noah H.; Allen, Albert R.

    2016-01-01

    This report documents acoustic testing of tuned chamber core panels, which can be used to supplement the low-frequency performance of conventional acoustic treatment. The tuned chamber core concept incorporates low-frequency noise control directly within the primary structure and is applicable to sandwich constructions with a directional core, including corrugated-, truss-, and fluted-core designs. These types of sandwich structures have long, hollow channels (or chambers) in the core. By adding small holes through one of the facesheets, the hollow chambers can be utilized as an array of low-frequency acoustic resonators. These resonators can then be used to attenuate low-frequency noise (below 400 Hz) inside a vehicle compartment without increasing the weight or size of the structure. The results of this test program demonstrate that the tuned chamber core concept is effective when used in isolation or combined with acoustic foam treatments. Specifically, an array of acoustic resonators integrated within the core of the panels was shown to improve both the low-frequency absorption and transmission loss of the structure in targeted one-third octave bands.

  20. Correlation measurements for fusion plasma diagnostics

    International Nuclear Information System (INIS)

    Pazsit, I.

    1995-01-01

    A list of a few methods for plasma diagnostics via fluctuations (noise) analysis of random (both temporally and spatially) system parameters is reviewed. Analogy is drawn with certain noise analysis methods, used in the diagnostics of fission reactors. These methods have been applied also to fusion measurements to some extent. However, the treatment of fusion plasma fluctuations is dominated by an approach that allows for temporal randomness, but assumes periodicity in space. This approach suits well a large class of phenomena such as magnetic fluctuations (MHD effects), but is much less suited to treat localised effects such as turbulence and density fluctuations. This paper discusses the potentials of the former approach, i.e. ordinary noise analysis methods of non-periodic variables in fusion plasma diagnostics. A new recommendation is to use the crossed beam correlation analysis of soft X-ray signals for determining the local short-range correlations in the plasma and to perform a systematic exploration of the plasma spatial correlation structure with that and other methods. 16 refs, 7 figs

  1. Advanced Analytical Tools for the Characterization of Fundamental Jet Noise Sources and Structures, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — There is a need for innovative technologies and methods for noise reduction, noise prediction, and noise diagnostics. A comprehensive approach to reducing noise from...

  2. Characterization of the quasi-coherent oscillations by HIBP diagnostic in the TJ-II stellarator

    International Nuclear Information System (INIS)

    Krupnik, L.; Chmyga, A.A.; Dreval, N.; Khrebtov, S.M.; Komarov, A.D.; Kozachok, A.S.; Eliseev, L.; Melnikov, A.; Perfilov, S.V.; Alonso, A.; Pablos, J.L. de; Hidalgo, C.; Pedrosa, M.A.

    2005-01-01

    Quasicoherent oscillations have been observed in TJ-II plasma with different diagnostic. A recent improvement in the signal to noise ratio of the Heavy Ion Beam Probe (HIBP) diagnostic has allowed to observe the radial structure of these oscillations from the edge to the plasma core region. Edge quasi-coherent fluctuations (with frequencies near 20 kHz) have been observed in some configuration windows when plasma density / heating power are above a threshold. The amplitude of those modes tends to be larger in the low field side region. This result suggests the role of configuration (related to the presence of low order rationals in the plasma edge) and threshold gradients to trigger quasi-coherence modes. HIBP signals are strongly correlated with probe signals. When rationals move towards the plasma core (ρ ∼ 0.3), the modes are clearly seen in ECE emission and in HIBP secondary current and potential signals. These quasi-coherent oscillations (in range 20 kHz) have been connected with the development of electron internal transport barriers (e-ITB). Recent results show a decreasing in the mode amplitude as e-ITBs are fully developed. (author)

  3. Background noise exerts diverse effects on the cortical encoding of foreground sounds.

    Science.gov (United States)

    Malone, B J; Heiser, Marc A; Beitel, Ralph E; Schreiner, Christoph E

    2017-08-01

    In natural listening conditions, many sounds must be detected and identified in the context of competing sound sources, which function as background noise. Traditionally, noise is thought to degrade the cortical representation of sounds by suppressing responses and increasing response variability. However, recent studies of neural network models and brain slices have shown that background synaptic noise can improve the detection of signals. Because acoustic noise affects the synaptic background activity of cortical networks, it may improve the cortical responses to signals. We used spike train decoding techniques to determine the functional effects of a continuous white noise background on the responses of clusters of neurons in auditory cortex to foreground signals, specifically frequency-modulated sweeps (FMs) of different velocities, directions, and amplitudes. Whereas the addition of noise progressively suppressed the FM responses of some cortical sites in the core fields with decreasing signal-to-noise ratios (SNRs), the stimulus representation remained robust or was even significantly enhanced at specific SNRs in many others. Even though the background noise level was typically not explicitly encoded in cortical responses, significant information about noise context could be decoded from cortical responses on the basis of how the neural representation of the foreground sweeps was affected. These findings demonstrate significant diversity in signal in noise processing even within the core auditory fields that could support noise-robust hearing across a wide range of listening conditions. NEW & NOTEWORTHY The ability to detect and discriminate sounds in background noise is critical for our ability to communicate. The neural basis of robust perceptual performance in noise is not well understood. We identified neuronal populations in core auditory cortex of squirrel monkeys that differ in how they process foreground signals in background noise and that may

  4. Coupled-core fluxgate magnetometer: Novel configuration scheme and the effects of a noise-contaminated external signal

    Energy Technology Data Exchange (ETDEWEB)

    Palacios, Antonio [San Diego State University, Nonlinear Dynamical Systems Group, Department of Mathematics and Statistics, San Diego, CA 92182-7720 (United States)]. E-mail: palacios@euler.sdsu.edu; Aven, John [San Diego State University, Nonlinear Dynamical Systems Group, Department of Mathematics and Statistics, San Diego, CA 92182-7720 (United States); In, Visarath [Space and Naval Warfare Systems Center San Diego, Code 2363, 53560 Hull St, San Diego, CA 92152-5001 (United States)]. E-mail: visarath@spawar.navy.mil; Longhini, Patrick [Space and Naval Warfare Systems Center San Diego, Code 2363, 53560 Hull St, San Diego, CA 92152-5001 (United States); Kho, Andy [Space and Naval Warfare Systems Center San Diego, Code 2363, 53560 Hull St, San Diego, CA 92152-5001 (United States); Neff, Joseph D. [Space and Naval Warfare Systems Center San Diego, Code 2363, 53560 Hull St, San Diego, CA 92152-5001 (United States); Bulsara, Adi [Space and Naval Warfare Systems Center San Diego, Code 2363, 53560 Hull St, San Diego, CA 92152-5001 (United States)]. E-mail: bulsara@spawar.navy.mil

    2007-07-16

    Recent theoretical and experimental work has shown that unidirectional coupling can induce oscillations in overdamped and undriven nonlinear dynamical systems that are non-oscillatory when uncoupled; in turn, this has been shown to lead to new mechanisms for weak (compared to the energy barrier height) signal detection and amplification. The potential applications include fluxgate magnetometers, electric field sensors, and arrays of Superconducting Quantum Interference Device (SQUID) rings. In the particular case of the fluxgate magnetometer, we have developed a ''coupled-core fluxgate magnetometer'' (CCFM); this device has been realized in the laboratory and its dynamics used to quantify many properties that are generic to this class of systems and coupling. The CCFM operation is underpinned by the emergent oscillatory behavior in a unidirectionally coupled ring of wound ferromagnetic cores, each of which can be treated as an overdamped bistable dynamic system when uncoupled. In particular, one can determine the regimes of existence and stability of the (coupling-induced) oscillations, and the scaling behavior of the oscillation frequency. More recently, we studied the effects of a (Gaussian) magnetic noise floor on a CCFM system realized with N=3 coupled ferromagnetic cores. In this Letter, we first introduce a variation on the basic CCFM configuration that affords a path to enhanced device sensitivity, particularly for N>=3 coupled elements. We then analyze the response of the basic CCFM configuration as well as the new setup to a dc target signal that has a small noisy component (or ''contamination'')

  5. An automated computerized auscultation and diagnostic system for pulmonary diseases.

    Science.gov (United States)

    Abbas, Ali; Fahim, Atef

    2010-12-01

    Respiratory sounds are of significance as they provide valuable information on the health of the respiratory system. Sounds emanating from the respiratory system are uneven, and vary significantly from one individual to another and for the same individual over time. In and of themselves they are not a direct proof of an ailment, but rather an inference that one exists. Auscultation diagnosis is an art/skill that is acquired and honed by practice; hence it is common to seek confirmation using invasive and potentially harmful imaging diagnosis techniques like X-rays. This research focuses on developing an automated auscultation diagnostic system that overcomes the limitations inherent in traditional auscultation techniques. The system uses a front end sound signal filtering module that uses adaptive Neural Networks (NN) noise cancellation to eliminate spurious sound signals like those from the heart, intestine, and ambient noise. To date, the core diagnosis module is capable of identifying lung sounds from non-lung sounds, normal lung sounds from abnormal ones, and identifying wheezes from crackles as indicators of different ailments.

  6. Low noise signal-to-noise ratio enhancing readout circuit for current-mediated active pixel sensors

    International Nuclear Information System (INIS)

    Ottaviani, Tony; Karim, Karim S.; Nathan, Arokia; Rowlands, John A.

    2006-01-01

    Diagnostic digital fluoroscopic applications continuously expose patients to low doses of x-ray radiation, posing a challenge to both the digital imaging pixel and readout electronics when amplifying small signal x-ray inputs. Traditional switch-based amorphous silicon imaging solutions, for instance, have produced poor signal-to-noise ratios (SNRs) at low exposure levels owing to noise sources from the pixel readout circuitry. Current-mediated amorphous silicon pixels are an improvement over conventional pixel amplifiers with an enhanced SNR across the same low-exposure range, but whose output also becomes nonlinear with increasing dosage. A low-noise SNR enhancing readout circuit has been developed that enhances the charge gain of the current-mediated active pixel sensor (C-APS). The solution takes advantage of the current-mediated approach, primarily integrating the signal input at the desired frequency necessary for large-area imaging, while adding minimal noise to the signal readout. Experimental data indicates that the readout circuit can detect pixel outputs over a large bandwidth suitable for real-time digital diagnostic x-ray fluoroscopy. Results from hardware testing indicate that the minimum achievable C-APS output current that can be discerned at the digital fluoroscopic output from the enhanced SNR readout circuit is 0.341 nA. The results serve to highlight the applicability of amorphous silicon current-mediated pixel amplifiers for large-area flat panel x-ray imagers

  7. Comparison of diagnostic classification systems for delirium with new research criteria that incorporate the three core domains.

    Science.gov (United States)

    Trzepacz, Paula T; Meagher, David J; Franco, José G

    2016-05-01

    Diagnostic classification systems do not incorporate phenomenological research findings about the three core symptom domains of delirium (Attentional/Cognitive, Circadian, Higher Level Thinking). We evaluated classification performances of novel Trzepacz, Meagher, and Franco research diagnostic criteria (TMF) that incorporate those domains and ICD-10, DSM-III-R, DSM-IV, and DSM-5. Primary data analysis of 641 patients with mixed neuropsychiatric profiles. Delirium (n=429) and nondelirium (n=212) reference standard groups were identified using cluster analysis of symptoms assessed using the Delirium Rating Scale-Revised-98. Accuracy, sensitivity, specificity, positive and negative predictive values (PPV, NPV), and likelihood ratios (LR+, LR-) are reported. TMF criteria had high sensitivity and specificity (87.4% and 89.2%), more balanced than DSM-III-R (100% and 31.6%), DSM-IV (97.7% and 74.1%), DSM-5 (97.7% and 72.6%), and ICD-10 (66.2% and 100%). PPV of DSM-III-R, DSM-IV, and DSM-5 were 90%. ICD-10 had the lowest NPV (59.4%). TMF had the highest LR+ (8.06) and DSM-III-R the lowest LR- (0.0). Overall, values for DSM-IV and DSM-5 were similar, whereas for ICD-10 and DSM-III-R were inverse of each other. In the pre-existing cognitive impairment/dementia subsample (n=128), TMF retained its highest LR+ though specificity (58.3%) became less well balanced with sensitivity (87.9%), which still exceeded that of DSM. TMF research diagnostic criteria performed well, with more balanced sensitivity and specificity and the highest likelihood ratio for delirium identification. Reflecting the three core domains of delirium, TMF criteria may have advantages in biological research where delineation of this syndrome is important. Copyright © 2016. Published by Elsevier Inc.

  8. Iterative noise removal from temperature and density profiles in the TJ-II Thomson scattering

    International Nuclear Information System (INIS)

    Farias, G.; Dormido-Canto, S.; Vega, J.; Santos, M.; Pastor, I.; Fingerhuth, S.; Ascencio, J.

    2014-01-01

    TJ-II Thomson Scattering diagnostic provides temperature and density profiles of plasma. The CCD camera acquires images that are corrupted with some kind of noise called stray-light. This noise degrades both image contrast and measurement accuracy, which could produce unreliable profiles of the diagnostic. So far, several approaches have been applied in order to decrease the noise in the TJ-II Thomson scattering images. Since the presence of the noise is not global but located in some particular regions of the image, advanced processing techniques are needed. However such methods require of manual fine-tuning of parameters to reach a good performance. In this contribution, an iterative image processing approach is applied in order to reduce the stray light effects in the images of the TJ-II Thomson scattering diagnostic. The proposed solution describes how the noise can be iteratively reduced in the images when a key parameter is automatically adjusted during the iterative process

  9. Iterative noise removal from temperature and density profiles in the TJ-II Thomson scattering

    Energy Technology Data Exchange (ETDEWEB)

    Farias, G., E-mail: gonzalo.farias@ucv.cl [Pontificia Universidad Católica de Valparaíso, Av. Brasil 2147, Valparaíso (Chile); Dormido-Canto, S., E-mail: sebas@dia.uned.es [Departamento de Informática y Automática, UNED, 28040 Madrid (Spain); Vega, J., E-mail: jesus.vega@ciemat.es [Asociación EURATOM/CIEMAT para Fusión, Avd. Complutense 22, 28040 Madrid (Spain); Santos, M., E-mail: msantos@ucm.es [Departamento de Arquitectura de Computadores y Automática, Universidad Complutense de Madrid, 28040 Madrid (Spain); Pastor, I., E-mail: ignacio.pastor@ciemat.es [Asociación EURATOM/CIEMAT para Fusión, Avd. Complutense 22, 28040 Madrid (Spain); Fingerhuth, S., E-mail: sebastian.fingerhuth@ucv.cl [Pontificia Universidad Católica de Valparaíso, Av. Brasil 2147, Valparaíso (Chile); Ascencio, J., E-mail: j_ascencio21@hotmail.com [Pontificia Universidad Católica de Valparaíso, Av. Brasil 2147, Valparaíso (Chile)

    2014-05-15

    TJ-II Thomson Scattering diagnostic provides temperature and density profiles of plasma. The CCD camera acquires images that are corrupted with some kind of noise called stray-light. This noise degrades both image contrast and measurement accuracy, which could produce unreliable profiles of the diagnostic. So far, several approaches have been applied in order to decrease the noise in the TJ-II Thomson scattering images. Since the presence of the noise is not global but located in some particular regions of the image, advanced processing techniques are needed. However such methods require of manual fine-tuning of parameters to reach a good performance. In this contribution, an iterative image processing approach is applied in order to reduce the stray light effects in the images of the TJ-II Thomson scattering diagnostic. The proposed solution describes how the noise can be iteratively reduced in the images when a key parameter is automatically adjusted during the iterative process.

  10. Autonomous data acquisition system for Paks NPP process noise signals

    International Nuclear Information System (INIS)

    Lipcsei, S.; Kiss, S.; Czibok, T.; Dezso, Z.; Horvath, Cs.

    2005-01-01

    A prototype of a new concept noise diagnostics data acquisition system has been developed recently to renew the aged present system. This new system is capable of collecting the whole available noise signal set simultaneously. Signal plugging and data acquisition are performed by autonomous systems (installed at each reactor unit) that are controlled through the standard plant network from a central computer installed at a suitable location. Experts can use this central unit to process and archive data series downloaded from the reactor units. This central unit also provides selected noise diagnostics information for other departments. The paper describes the hardware and software architecture of the new system in detail, emphasising the potential benefits of the new approach. (author)

  11. Methodology for Identification of the Coolant Thermalhydraulic Regimes in the Core of Nuclear Reactors

    International Nuclear Information System (INIS)

    Sharaevsky, L.G.; Sharaevskaya, E.I.; Domashev, E.D.; Arkhypov, A.P.; Kolochko, V.N.

    2002-01-01

    The paper deals with one of the acute for the nuclear energy problem of accident regimes of NPPs recognition diagnostics using noise signal diagnostics methodology. The methodology intends transformation of the random noise signals of the main technological parameters at the exit of a nuclear facility (neutron flow, dynamic pressure etc.) which contain the important information about the technical status of the equipment. The effective algorithms for identification of random processes wore developed. After proper transformation its were considered as multidimensional random vectors. Automatic classification of these vectors in the developed algorithms is realized on the basis of the probability function in particular Bayes classifier and decision functions. Till now there no mathematical models for thermalhydraulic regimes of fuel assemblies recognition on the acoustic and neutron noises parameters in the core of nuclear facilities. The two mathematical models for analysis of the random processes submitted to the automatic classification is proposed, i.e. statistical (using Bayes classifier of acoustic spectral density diagnosis signals) and geometrical (on the basis of formation in the featured space of dividing hyper-plane). The theoretical basis of the bubble boiling regimes in the fuel assemblies is formulated as identification of these regimes on the basis of random parameters of auto spectral density of acoustic noise (ASD) measured in the fuel assemblies (dynamic pressure in the upper plenum in the paper). The elaborated algorithms allow recognize realistic status of the fuel assemblies. For verification of the proposed mathematical models the analysis of experimental measurements was carried out. The research of the boiling onset and definition of the local values of the flow parameters in the seven-beam fuel assembly (length of 1.3 m, diameter of 6 mm) have shown the correct identification of the bubble boiling regimes. The experimental measurements on

  12. High-frequency noise modeling of Si(Ge) bipolar transistors

    NARCIS (Netherlands)

    Vitale, F.

    2014-01-01

    The design and the optimization of electronic systems often requires a detailed knowledge of the inherent noise generated within semiconductor active devices, constituting the core of such systems. Examples of applications in which noise is a key issue include receiver front-ends in radiofrequency

  13. Acoustic Database for Turbofan Engine Core-Noise Sources. I; Volume

    Science.gov (United States)

    Gordon, Grant

    2015-01-01

    In this program, a database of dynamic temperature and dynamic pressure measurements were acquired inside the core of a TECH977 turbofan engine to support investigations of indirect combustion noise. Dynamic temperature and pressure measurements were recorded for engine gas dynamics up to temperatures of 3100 degrees Fahrenheit and transient responses as high as 1000 hertz. These measurements were made at the entrance of the high pressure turbine (HPT) and at the entrance and exit of the low pressure turbine (LPT). Measurements were made at two circumferential clocking positions. In the combustor and inter-turbine duct (ITD), measurements were made at two axial locations to enable the exploration of time delays. The dynamic temperature measurements were made using dual thin-wire thermocouple probes. The dynamic pressure measurements were made using semi-infinite probes. Prior to the engine test, a series of bench, oven, and combustor rig tests were conducted to characterize the performance of the dual wire temperature probes and to define and characterize the data acquisition systems. A measurement solution for acquiring dynamic temperature and pressure data on the engine was defined. A suite of hardware modifications were designed to incorporate the dynamic temperature and pressure instrumentation into the TECH977 engine. In particular, a probe actuation system was developed to protect the delicate temperature probes during engine startup and transients in order to maximize sensor life. A set of temperature probes was procured and the TECH977 engine was assembled with the suite of new and modified hardware. The engine was tested at four steady state operating speeds, with repeats. Dynamic pressure and temperature data were acquired at each condition for at least one minute. At the two highest power settings, temperature data could not be obtained at the forward probe locations since the mean temperatures exceeded the capability of the probes. The temperature data

  14. CT-guided transthoracic core needle biopsy for small pulmonary lesions: diagnostic performance and adequacy for molecular testing.

    Science.gov (United States)

    Tian, Panwen; Wang, Ye; Li, Lei; Zhou, Yongzhao; Luo, Wenxin; Li, Weimin

    2017-02-01

    Computed tomography (CT)-guided transthoracic needle biopsy is a well-established, minimally invasive diagnostic tool for pulmonary lesions. Few large studies have been conducted on the diagnostic performance and adequacy for molecular testing of transthoracic core needle biopsy (TCNB) for small pulmonary lesions. This study included CT-guided TCNB with 18-gauge cutting needles in 560 consecutive patients with small (≤3 cm) pulmonary lesions from January 2012 to January 2015. There were 323 males and 237 females, aged 51.8±12.7 years. The size of the pulmonary lesions was 1.8±0.6 cm. The sensitivity, specificity, accuracy and complications of the biopsies were investigated. The risk factors of diagnostic failure were assessed using univariate and multivariate analyses. The sample's adequacy for molecular testing of non-small cell lung cancer (NSCLC) was analyzed. The overall sensitivity, specificity, and accuracy for diagnosis of malignancy were 92.0% (311/338), 98.6% (219/222), and 94.6% (530/560), respectively. The incidence of bleeding complications was 22.9% (128/560), and the incidence of pneumothorax was 10.4% (58/560). Logistic multivariate regression analysis showed that the independent risk factors for diagnostic failure were a lesion size ≤1 cm [odds ratio (OR), 3.95; P=0.007], lower lobe lesions (OR, 2.83; P=0.001), and pneumothorax (OR, 1.98; P=0.004). Genetic analysis was successfully performed on 95.45% (168/176) of specimens diagnosed as NSCLC. At least 96.8% of samples with two or more passes from a lesion were sufficient for molecular testing. The diagnostic yield of small pulmonary lesions by CT-guided TCNB is high, and the procedure is relatively safe. A lesion size ≤1 cm, lower lobe lesions, and pneumothorax are independent risk factors for biopsy diagnostic failure. TCNB specimens could provide adequate tissues for molecular testing.

  15. Major aspects of the design of a first mirror for the ITER core CXRS diagnostics

    International Nuclear Information System (INIS)

    Krasikov, Yury; Panin, Anatoly; Biel, Wolfgang; Krimmer, Andreas; Litnovsky, Andrey; Mertens, Philippe; Neubauer, Olaf; Schrader, Michael

    2015-01-01

    Highlights: • Availability, technological issues, and changes in the ScMo structure to be solved in future. • Developed passively cooled mirror is a workable, flexible, scalable and robust concept. • The generic upper port plug is to be considerable customized. - Abstract: The ITER core charge exchange recombination spectroscopy diagnostics (cCXRS) occupies the vacuum vessel upper port #3 and includes, in its generic version, the following in-vessel components: an optical mirror system, a shutter, the diagnostic first wall and the neutron shielding block. The most vulnerable diagnostic mirror is obviously the first one (M1) directly observing the plasma. The M1 reference option is made of a single crystalline molybdenum (ScMo). The paper indicates major aspects influencing the first mirror design and identifies the most reasonable and reliable concept for cCXRS M1 at present. The applicability of the option presented is determined by many reasons, and especially, by the ITER generic upper port plug and its customization flexibility. The largest dimension of the mirror polished face is ∼300 mm. Such large ScMo workpieces are currently not available on the market. The mirror should be designed as an assembly of several ScMo pieces joined together. The M1 design is supported by multifield thermal, electromagnetic and structural analyses. The performed study confirms the feasibility of the proposed solutions. At the same time, the paper indicates numerous technological issues of the M1 unit to be solved in future.

  16. Major aspects of the design of a first mirror for the ITER core CXRS diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Krasikov, Yury, E-mail: y.krasikov@fz-juelich.de; Panin, Anatoly; Biel, Wolfgang; Krimmer, Andreas; Litnovsky, Andrey; Mertens, Philippe; Neubauer, Olaf; Schrader, Michael

    2015-10-15

    Highlights: • Availability, technological issues, and changes in the ScMo structure to be solved in future. • Developed passively cooled mirror is a workable, flexible, scalable and robust concept. • The generic upper port plug is to be considerable customized. - Abstract: The ITER core charge exchange recombination spectroscopy diagnostics (cCXRS) occupies the vacuum vessel upper port #3 and includes, in its generic version, the following in-vessel components: an optical mirror system, a shutter, the diagnostic first wall and the neutron shielding block. The most vulnerable diagnostic mirror is obviously the first one (M1) directly observing the plasma. The M1 reference option is made of a single crystalline molybdenum (ScMo). The paper indicates major aspects influencing the first mirror design and identifies the most reasonable and reliable concept for cCXRS M1 at present. The applicability of the option presented is determined by many reasons, and especially, by the ITER generic upper port plug and its customization flexibility. The largest dimension of the mirror polished face is ∼300 mm. Such large ScMo workpieces are currently not available on the market. The mirror should be designed as an assembly of several ScMo pieces joined together. The M1 design is supported by multifield thermal, electromagnetic and structural analyses. The performed study confirms the feasibility of the proposed solutions. At the same time, the paper indicates numerous technological issues of the M1 unit to be solved in future.

  17. Research and Development Program in Reactor Diagnostics and Monitoring with Neutron Noise Methods, Stage 16

    Energy Technology Data Exchange (ETDEWEB)

    Pazsit, Imre; Dykin, Victor; Jonsson, Anders; Demaziere, Christophe (Chalmers Univ. of Technology, Dept. of Nuclear Engineering, Goeteborg (Sweden))

    2010-12-15

    This report gives an account of the work performed by the Dept. of Nuclear Engineering, Chalmers Univ. of Technology, in the frame of a research contract with the Swedish Radiation Safety Authority (SSM), contract No. SSM 2009/2093. The present report is based on work performed by Imre Pazsit, Victor Dykin, Anders Jonsson and Christophe Demaziere, with Imre Pazsit being the project leader. This report describes the results obtained during Stage 16 of a long-term research and development program concerning the development of diagnostics and monitoring methods for nuclear reactors. The long-term goals are elaborated in more detail in e.g. the Final Reports of Stage 1 and 2 (SKI Report 95:14 and 96:50, Pazsit et al. 1995, 1996). Results up to Stage 15 were reported in (Pazsit et al. 1995, 1996, 1997, 1998, 1999, 2000, 2001, 2003a, 2003b; Demaziere et al, 2004; Sunde et al, 2006; Pazsit et al. 2008, 2009). A brief proposal for the continuation of this program in Stage 17 is also given at the end of the report. The program executed in Stage 16 consists of four parts as follows: - An overview of the present status of experience with BWR stability; - An investigation of the significance of the properties of the noise source for BWR instability; - Study of the dynamics of molten salt systems: construction of the adjoint and calculating the space dependent noise induced by propagating perturbations in the fuel; - A specific study of some novel methods of analysis of non-linear and non-stationary processes

  18. Research and Development Program in Reactor Diagnostics and Monitoring with Neutron Noise Methods, Stage 16

    International Nuclear Information System (INIS)

    Pazsit, Imre; Dykin, Victor; Jonsson, Anders; Demaziere, Christophe

    2010-12-01

    This report gives an account of the work performed by the Dept. of Nuclear Engineering, Chalmers Univ. of Technology, in the frame of a research contract with the Swedish Radiation Safety Authority (SSM), contract No. SSM 2009/2093. The present report is based on work performed by Imre Pazsit, Victor Dykin, Anders Jonsson and Christophe Demaziere, with Imre Pazsit being the project leader. This report describes the results obtained during Stage 16 of a long-term research and development program concerning the development of diagnostics and monitoring methods for nuclear reactors. The long-term goals are elaborated in more detail in e.g. the Final Reports of Stage 1 and 2 (SKI Report 95:14 and 96:50, Pazsit et al. 1995, 1996). Results up to Stage 15 were reported in (Pazsit et al. 1995, 1996, 1997, 1998, 1999, 2000, 2001, 2003a, 2003b; Demaziere et al, 2004; Sunde et al, 2006; Pazsit et al. 2008, 2009). A brief proposal for the continuation of this program in Stage 17 is also given at the end of the report. The program executed in Stage 16 consists of four parts as follows: - An overview of the present status of experience with BWR stability; - An investigation of the significance of the properties of the noise source for BWR instability; - Study of the dynamics of molten salt systems: construction of the adjoint and calculating the space dependent noise induced by propagating perturbations in the fuel; - A specific study of some novel methods of analysis of non-linear and non-stationary processes

  19. [Effects of urban noise on mental health].

    Science.gov (United States)

    Belojević, G; Jakovljević, B; Kocijancić, R; Pjerotić, L; Dimitrijević, J

    1995-01-01

    The results of the latest studies on the effects of urban noise on mental health are presented in this paper. Numerous psychiatric symptoms have been frequently noticed in the population of the settlements with a high level of urban noise: fatigue, headaches, tension, anxiety, irritability, bad concentration, insomnia, whith a consequently high consumption of psychotropic medicines. Higher admission rates in psychiatric hospitals have been noticed from noisy areas in comparison with low noise regions. By use of diagnostic psychiatric interviews it has been shown as well, that in sensitive categories of population positive correlation can be expected between the number of persons with mental disorder and the level of environmental noise. Noise annoyance and sleep disturbance, namely shortening or absence of the sleep phase 4 and REM, are the basic negative psychological effects of noise, with an adverse effect on mental health in general.

  20. Fundamental and applied research on core engine/combustion noise of aircraft engines

    Science.gov (United States)

    Plett, E. G.; Leshner, M. D.; Summerfield, M.

    1974-01-01

    Some results of a study of the importance of geometrical features of the combustor to combustion roughness and resulting noise are presented. Comparison is made among a perforated can flame holder, a plane slotted flame holder and a plane slotted flame holder which introduces two counter swirling streams. The latter is found to permit the most stable, quiet combustion. Crosscorrelations between the time derivative of chamber pressure fluctuations and far field noise are found to be stronger than between the far field noise and the direct chamber pressure signal. Temperature fluctuations in the combustor nozzle are also found to have a reasonably strong crosscorrelation with far field sound.

  1. Application of Continuous and Structural ARMA modeling for noise analysis of a BWR coupled core and plant instability event

    International Nuclear Information System (INIS)

    Demeshko, M.; Dokhane, A.; Washio, T.; Ferroukhi, H.; Kawahara, Y.; Aguirre, C.

    2015-01-01

    Highlights: • We demonstrate the first application of a novel CSARMA method. • We analyze the instability occurred in a Swiss BWR plant during power ascension. • Benchmarked the results against STP analysis. • The CSARMA results are consistent with the background physics and the STP results. • The instability was caused by disturbances in the pressure control system. - Abstract: This paper presents a first application of a novel Continuous and Structural Autoregressive Moving Average (CSARMA) modeling approach to BWR noise analysis. The CSARMA approach derives a unique representation of the system dynamics by more robust and reliable canonical models as basis for signal analysis in general and for reactor diagnostics in particular. In this paper, a stability event that occurred in a Swiss BWR plant during power ascension phase is analyzed as well as the time periods that preceded and followed the event. Focusing only on qualitative trends at this stage, the obtained results clearly indicate a different dynamical state during the unstable event compared to the two other stable periods. Also, they could be interpreted as pointing out a disturbance in the pressure control system as primary cause for the event. To benchmark these findings, the frequency-domain based signal transmission-path (STP) method is also applied. And with the STP method, we obtained similar relationships as mentioned above. This consistency between both methods can be considered as being a confirmation that the event was caused by a pressure control system disturbance and not induced by the core. Also, it is worth noting that the STP analysis failed to catch the relations among the processes during the stable periods, that were clearly indicated by the CSARMA method, since the last uses more precise models as basis

  2. Orbital Noise of the Earth Causes Intensity Fluctuation in the Geomagnetic Field

    Science.gov (United States)

    Liu, Han-Shou; Kolenkiewicz, R.; Wade, C., Jr.

    2003-01-01

    Orbital noise of Earth's obliquity can provide an insight into the core of the Earth that causes intensity fluctuations in the geomagnetic field. Here we show that noise spectrum of the obliquity frequency have revealed a series of frequency periods centered at 250-, 1OO-, 50-, 41-, 30-, and 26-kyr which are almost identical with the observed spectral peaks from the composite curve of 33 records of relative paleointensity spanning the past 800 kyr (Sint-800 data). A continuous record for the past two million years also reveals the presence of the major 100 kyr periodicity in obliquity noise and geomagnetic intensity fluctuations. These results of correlation suggest that obliquity noise may power the dynamo, located in the liquid outer core of the Earth, which generates the geomagnetic field.

  3. Utilizing benchmark data from the ANL-ZPR diagnostic cores program

    International Nuclear Information System (INIS)

    Schaefer, R. W.; McKnight, R. D.

    2000-01-01

    The support of the criticality safety community is allowing the production of benchmark descriptions of several assemblies from the ZPR Diagnostic Cores Program. The assemblies have high sensitivities to nuclear data for a few isotopes. This can highlight limitations in nuclear data for selected nuclides or in standard methods used to treat these data. The present work extends the use of the simplified model of the U9 benchmark assembly beyond the validation of k eff . Further simplifications have been made to produce a data testing benchmark in the style of the standard CSEWG benchmark specifications. Calculations for this data testing benchmark are compared to results obtained with more detailed models and methods to determine their biases. These biases or corrections factors can then be applied in the use of the less refined methods and models. Data testing results using Versions IV, V, and VI of the ENDF/B nuclear data are presented for k eff , f 28 /f 25 , c 28 /f 25 , and β eff . These limited results demonstrate the importance of studying other integral parameters in addition to k eff in trying to improve nuclear data and methods and the importance of accounting for methods and/or modeling biases when using data testing results to infer the quality of the nuclear data files

  4. Noise analysis method for monitoring the moderator temperature coefficient of pressurized water reactors: Neural network calibration

    International Nuclear Information System (INIS)

    Thomas, J.R. Jr.; Adams, J.T.

    1994-01-01

    A neural network was trained with data for the frequency response function between in-core neutron noise and core-exit thermocouple noise in a pressurized water reactor, with the moderator temperature coefficient (MTC) as target. The trained network was subsequently used to predict the MTC at other points in the same fuel cycle. Results support use of the method for operating pressurized water reactors provided noise data can be accumulated for several fuel cycles to provide a training base

  5. Nuclear power plant diagnostic system

    International Nuclear Information System (INIS)

    Prokop, K.; Volavy, J.

    1982-01-01

    Basic information is presented on diagnostic systems used at nuclear power plants with PWR reactors. They include systems used at the Novovoronezh nuclear power plant in the USSR, at the Nord power plant in the GDR, the system developed at the Hungarian VEIKI institute, the system used at the V-1 nuclear power plant at Jaslovske Bohunice in Czechoslovakia and systems of the Rockwell International company used in US nuclear power plants. These diagnostic systems are basically founded on monitoring vibrations and noise, loose parts, pressure pulsations, neutron noise, coolant leaks and acoustic emissions. The Rockwell International system represents a complex unit whose advantage is the on-line evaluation of signals which gives certain instructions for the given situation directly to the operator. The other described systems process signals using similar methods. Digitized signals only serve off-line computer analyses. (Z.M.)

  6. Application of some pattern recognition methods for the early detection of failures at NPP components by means of noise diagnosis

    International Nuclear Information System (INIS)

    Weiss, F.P.

    1985-01-01

    The automation of the decisions on normality or abnormality of the plant condition being based on automated measurements is an essential step for the integration of noise diagnostics into the control and safety system of a nuclear power plant. By reason of the stochastic character of noise diagnostic measuring quantities principles of statistical pattern recognition are used in order automatically to get a decision on the plant condition. Four different pattern recognition methods complementing each other have been developed respectively tested with data from a WWER-440 type reactor. These four methods are included in a specially written software package. According to stationarity, correlation and probability distribution type of the state describing features and according to the necessary detection sensitivity to failures either the decorrelation method, the cluster method, the Parzen method or the distribution test of Wilcoxon, Mann and Whitney has to be applied. The efficiency and the limits of the investigated methods are discussed in detail. In context with the surveillance of the WWER-440 core by means of the power spectral densities of neutron flux fluctuations it could as well experimentally as theoretically be shown that the logarithmic power spectral densities follow a Gaussian probability distribution. (author)

  7. Transition to turbulence and noise radiation in heated coaxial jet flows

    Energy Technology Data Exchange (ETDEWEB)

    Gloor, Michael, E-mail: gloor@ifd.mavt.ethz.ch; Bühler, Stefan; Kleiser, Leonhard [Institute of Fluid Dynamics, ETH Zurich, 8092 Zurich (Switzerland)

    2016-04-15

    Laminar-turbulent transition and noise radiation of a parametrized set of subsonic coaxial jet flows with a hot primary (core) stream are investigated numerically by Large-Eddy Simulation (LES) and direct noise computation. This study extends our previous research on local linear stability of heated coaxial jet flows by analyzing the nonlinear evolution of initially laminar flows disturbed by a superposition of small-amplitude unstable eigenmodes. First, a baseline configuration is studied to shed light on the flow dynamics of coaxial jet flows. Subsequently, LESs are performed for a range of Mach and Reynolds numbers to systematically analyze the influences of the temperature and the velocity ratios between the primary and the secondary (bypass) stream. The results provide a basis for a detailed analysis of fundamental flow-acoustic phenomena in the considered heated coaxial jet flows. Increasing the primary-jet temperature leads to an increase of fluctuation levels and to an amplification of far-field noise, especially at low frequencies. Strong mixing between the cold bypass stream and the hot primary stream as well as the intermittent character of the flow field at the end of the potential core lead to a pronounced noise radiation at an aft angle of approximately 35{sup ∘}. The velocity ratio strongly affects the shear-layer development and therefore also the noise generation mechanisms. Increasing the secondary-stream velocity amplifies the dominance of outer shear-layer perturbations while the disturbance growth rates in the inner shear layer decrease. Already for r{sub mic} > 40R{sub 1}, where r{sub mic} is the distance from the end of the potential core and R{sub 1} is the core-jet radius, a perfect 1/r{sub mic} decay of the sound pressure amplitudes is observed. The potential-core length increases for higher secondary-stream velocities which leads to a shift of the center of the dominant acoustic radiation in the downstream direction.

  8. ACVP-02: Plasma SIV/SHIV RNA Viral Load Measurements through the AIDS and Cancer Virus Program Quantitative Molecular Diagnostics Core | Frederick National Laboratory for Cancer Research

    Science.gov (United States)

    The SIV plasma viral load assay performed by the Quantitative Molecular Diagnostics Core (QMDC) utilizes reagents specifically designed to detect and accurately quantify the full range of SIV/SHIV viral variants and clones in common usage in the rese

  9. Summary from working group on noninterceptive diagnostics

    International Nuclear Information System (INIS)

    Chamberlin, D.D.

    1985-01-01

    The working group for noninterceptive diagnostics spent much of its time comparing diagnostic techniques from different fields and their possible application to high-power injectors. The group included backgrounds from electron beam diagnostics, fusion power diagnostics, cw ion source and transport design, and ion beam of diagnostics. The probability of success for adapting techniques from these different areas is quite difficult to judge, short of a detailed examination of each application. Unexpected flaws or unforeseen noise sources can eliminate an idea that would otherwise appear promising. The report presents several ideas that were discussed, with an indication of those ideas most likely to succeed if implemented

  10. Application of noise analysis technique for monitoring the moderator temperature coefficient of reactivity in pressurized water reactors

    International Nuclear Information System (INIS)

    Shieh, D.J.; Upadhyaya, B.R.; Sweeney, F.J.

    1987-01-01

    A new technique, based on the noise analysis of neutron detector and core-exit coolant temperature signals, is developed for monitoring the moderator temperature coefficient of reactivity in pressurized water reactors (PWRs). A detailed multinodal model is developed and evaluated for the reactor core subsystem of the loss-of-fluid test (LOFT) reactor. This model is used to study the effect of changing the sign of the moderator temperature coefficient of reactivity on the low-frequency phase angle relationship between the neutron detector and the core-exit temperature noise signals. Results show that the phase angle near zero frequency approaches - 180 deg for negative coefficients and 0 deg for positive coefficients when the perturbation source for the noise signals is core coolant flow, inlet coolant temperature, or random heat transfer

  11. Image quality - physical and diagnostic parameters. The radiologist's viewpoint

    International Nuclear Information System (INIS)

    Stender, H.St.

    1985-01-01

    The quality of a radiograph is determined by the diagnostic information it provides. This depends upon the visual detection of diagnostically relevant structures. The technical radiographic requirements are dependent upon the physical measurements and the physiological and optical conditions. Such physical factors as spatial resolution, contrast and noise are quantitative measurements, which must be oriented to the qualitative visual characteristics of the radiograph. The influence of subjective perception and complexity of structural noise on the detectability of details and structures particularly demands attention. Since radiographic quality depends upon the detection of diagnostically relevant structure and features, it is important to define these parameters on the basis of extensive radiographic analysis and the corresponding clinical findings. The diagnostically relevant radiographic parameters and image details and critical structures have been worked out for the examination of the lungs, colon, stomach, urinary tract and skeleton. Good image quality requires coordination of the physical-technical parameters with the visual ability of the observer, since only in this way can the diagnostic information be represented with sufficient clarity. (author)

  12. Propulsion Noise Reduction Research in the NASA Advanced Air Transport Technology Project

    Science.gov (United States)

    Van Zante, Dale; Nark, Douglas; Fernandez, Hamilton

    2017-01-01

    The Aircraft Noise Reduction (ANR) sub-project is focused on the generation, development, and testing of component noise reduction technologies progressing toward the NASA far term noise goals while providing associated near and mid-term benefits. The ANR sub-project has efforts in airframe noise reduction, propulsion (including fan and core) noise reduction, acoustic liner technology, and propulsion airframe aeroacoustics for candidate conventional and unconventional aircraft configurations. The current suite of propulsion specific noise research areas is reviewed along with emerging facility and measurement capabilities. In the longer term, the changes in engine and aircraft configuration will influence the suite of technologies necessary to reduce noise in next generation systems.

  13. Accessible or Inaccessible? Diagnostic Efficacy of CT-Guided Core Biopsies of Head and Neck Masses

    Energy Technology Data Exchange (ETDEWEB)

    Cunningham, Jane D., E-mail: janecunningham0708@gmail.com; McCusker, Mark W.; Power, Sarah; PearlyTi, Joanna; Thornton, John; Brennan, Paul; Lee, Michael J.; O’Hare, Alan; Looby, Seamus [Beaumont Hospital, Department of Radiology (Ireland)

    2015-04-15

    PurposeTissue sampling of lesions in the head and neck is challenging due to complex regional anatomy and sometimes necessitates open surgical biopsy. However, many patients are poor surgical candidates due to comorbidity. Thus, we evaluated the use of CT guidance for establishing histopathological diagnosis of head and neck masses.MethodsAll consecutive patients (n = 22) who underwent CT-guided core biopsy of head or neck masses between April 2009 and August 2012 were retrospectively reviewed using the departmental CT interventional procedures database. The indication for each biopsy performed was to establish or exclude a diagnosis of neoplasia in patients with suspicious head or neck lesions found on clinical examination or imaging studies. Patients received conscious sedation and 18 G, semiautomated core needle biopsies were performed by experienced neuroradiologists using 16-slice multidetector row CT imaging guidance (Somatom Definition Siemens Medical Solutions, Germany). Histopathology results of each biopsy were analysed.ResultsSixteen of 22 biopsies that were performed (73 %) yielded a pathological diagnosis. Anatomic locations biopsied included: masticator (n = 7), parapharyngeal (n = 3), parotid (n = 3), carotid (n = 3), perivertebral (n = 3), pharyngeal (n = 2), and retropharyngeal (n = 1) spaces. Six biopsies (27 %) were nondiagnostic due to inadequate tissue sampling, particularly small biopsy sample size and failure to biopsy the true sampling site due to extensive necrosis. No major complications were encountered.ConclusionsThe use of CT guidance to perform core biopsies of head and neck masses is an effective means of establishing histopathological diagnosis and reduces the need for diagnostic open surgical biopsy and general anaesthesia.

  14. Experience with a PC-based system for noise and DC signal analysis in PWRs

    International Nuclear Information System (INIS)

    Hashemian, H.M.

    1996-01-01

    A data acquisition system that was originally developed for noise diagnostics in PWRs was expanded to include DC signal analysis in addition to noise analysis. The system has been used in PWRs for reactor diagnostics, determination of root cause of process anomalies, instrument calibration verification, measurement of drop time of control and shutdown rods, testing of timing and sequencing of control rod drive mechanisms, emergency diesel generator monitoring, etc. These applications are reviewed in this paper. (author)

  15. Flow measurements using noise signals of axially displaced thermocouples

    Energy Technology Data Exchange (ETDEWEB)

    Kozma, R.; Hoogenboom, J.E. (Interuniversitair Reactor Inst., Delft (Netherlands))

    1990-01-01

    Determination of the flow rate of the coolant in the cooling channels of nuclear reactors is an important aspect of core monitoring. It is usually impossible to measure the flow by flowmeters in the individual channels due to the lack of space and safety reasons. An alternative method is based on the analysis of noise signals of the available in-core detectors. In such a noise method, a transit time which characterises the propagation of thermohydraulic fluctuations (density or temperature fluctuations) in the coolant is determined from the correlation between the noise signals of axially displaced detectors. In this paper, the results of flow measurements using axially displaced thermocouples in the channel wall will be presented. The experiments have been performed in a simulated MRT-type fuel assembly located in the research reactor HOR of the Interfaculty Reactor Institute, Delft. It was found that the velocities obtained via temperature noise correlation methods are significantly larger than the area-averaged velocity in the single-phase coolant flow. Model calculations show that the observed phenomenon can be explained by effects due to the radial velocity distribution in the channel. (author).

  16. Detection of HCV core antigen and its diagnostic significance

    Directory of Open Access Journals (Sweden)

    YANG Jie

    2013-02-01

    Full Text Available ObjectiveTo compare the abilities of the hepatitis C virus (HCV core antigen (cAg test and the HCV RNA assay for confirming anti-HCV presence in order to determine the clinical utility of the HCV-cAg as an alternative or confirmatory diagnostic tool. MethodsSerum samples collected from 158 patients diagnosed with HCV infection were subjected to the enzyme-linked immunosorbent assay-based HCV-cAg test. The optical density (OD measured values were used to calculate the ratio of specimen absorbance to the cutoff value (S/CO. Simultaneously, the serum samples were subjected to PCR-based nucleic acid amplification quantitative fluorescence detection of HCV RNA. ResultsNone of the serum samples had a S/CO value <1 for the HCV-cAg test (100% negative, but all of the samples had a S/CO value >5 (100% positive. The HCV-cAg test sensitivity was 87.05%, specificity was 76.67%, positive predictive value was 9653%, and negative predictive value was 44.23%. As the S/CO value gradually increased, the significantly higher positive coincident rate of the HCV RNA test decreased. The HCV RNA negative coincident rate was significantly higher than that of the HCV-cAg test. HCV-cAg S/CO values between 1 and 2 corresponded to an HCV RNA values between 1.0×103 copies/ml and 1.0×104 copies/ml. The highest S/CO value obtained was 1.992. ConclusionThe HCV-cAg test is comparable to the HCV RNA assay for diagnosing HCV infection.

  17. A wideband CMOS inductorless low noise amplifier employing noise cancellation for digital TV tuner applications

    International Nuclear Information System (INIS)

    Zhang Jihong; Bai Xuefei; Huang Lu

    2013-01-01

    A wideband inductorless low noise amplifier for digital TV tuner applications is presented. The proposed LNA scheme uses a composite NMOS/PMOS cross-coupled transistor pair to provide partial cancellation of noise generated by the input transistors. The chip is implemented in SMIC 0.18 μm CMOS technology. Measurement shows that the proposed LNA achieves 12.2–15.2 dB voltage gain from 300 to 900 MHz, the noise figure is below 3.1 dB and has a minimum value of 2.3 dB, and the best input-referred 1-dB compression point (IP1dB) is − 17 dBm at 900 MHz. The core consumes 7 mA current with a supply voltage of 1.8 V and occupies an area of 0.5 × 0.35 mm 2 . (semiconductor integrated circuits)

  18. Leak detection by vibrational diagnostic methods

    International Nuclear Information System (INIS)

    Siklossy, P.

    1983-01-01

    The possibilities and methods of leak detection due to mechanical failures in nuclear power plants are reviewed on the basis of the literature. Great importance is attributed to vibrational diagnostic methods for their adventageous characteristics which enable them to become final leak detecting methods. The problems of noise analysis, e.g. leak detection by impact sound measurements, probe characteristics, gain problems, probe selection, off-line analysis and correlation functions, types of leak noises etc. are summarized. Leak detection based on noise analysis can be installed additionally to power plants. Its maintenance and testing is simple. On the other hand, it requires special training and measuring methods. (Sz.J.)

  19. Wavelet and Spectral Analysis of Some Selected Problems in Reactor Diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Sunde, Carl

    2004-12-01

    Both spectral and wavelet analysis were successfully used in various diagnostic problems involving non-stationary core processes in nuclear power reactors. Three different problems were treated: two-phase flow identification, detector tube impacting and core-barrel vibrations. The first two problems are of non-stationary nature, whereas the last one is not. In the first problem, neutron radiographic and visible light images of four different vertical two-phase flow regimes, bubbly, slug, chum and annular flow, were analysed and classified with a neuro-wavelet algorithm. The algorithm consists of a wavelet part, using the 2-D discrete wavelet transform and of an artificial neural network. It classifies the different flow regimes with up to 99% efficiency. Detector tubes in a Boiling Water Reactor may execute vibrations and may also impact on nearby fuel-assemblies. Signals from in-core neutron detectors in Ringhals-1 were analysed, for detection of impacting, with both a classical spectral method and wavelet-based methods. The wavelet methods include both the discrete and the continuous 1-D wavelet transform. It was found that there is agreement between the different methods as well as with visual inspections made during the outage at the plant. However, the wavelet technique has the advantage that it does not require expert judgement for the interpretation of the analysis. In the last part two analytical calculations of the neutron noise, induced by shell-mode core-barrel vibrations, were carried out. The results are in good agreement with calculations from a numerical simulator. An out-of-phase behaviour between in-core and ex-core positions was found, which is in agreement with earlier measurements from the Pressurised Water Reactor Ringhals-3. The results from these calculations are planned to be used when diagnosing the shell-mode core-barrel vibrations in an operating plant.

  20. Wavelet and Spectral Analysis of Some Selected Problems in Reactor Diagnostics

    International Nuclear Information System (INIS)

    Sunde, Carl

    2004-12-01

    Both spectral and wavelet analysis were successfully used in various diagnostic problems involving non-stationary core processes in nuclear power reactors. Three different problems were treated: two-phase flow identification, detector tube impacting and core-barrel vibrations. The first two problems are of non-stationary nature, whereas the last one is not. In the first problem, neutron radiographic and visible light images of four different vertical two-phase flow regimes, bubbly, slug, chum and annular flow, were analysed and classified with a neuro-wavelet algorithm. The algorithm consists of a wavelet part, using the 2-D discrete wavelet transform and of an artificial neural network. It classifies the different flow regimes with up to 99% efficiency. Detector tubes in a Boiling Water Reactor may execute vibrations and may also impact on nearby fuel-assemblies. Signals from in-core neutron detectors in Ringhals-1 were analysed, for detection of impacting, with both a classical spectral method and wavelet-based methods. The wavelet methods include both the discrete and the continuous 1-D wavelet transform. It was found that there is agreement between the different methods as well as with visual inspections made during the outage at the plant. However, the wavelet technique has the advantage that it does not require expert judgement for the interpretation of the analysis. In the last part two analytical calculations of the neutron noise, induced by shell-mode core-barrel vibrations, were carried out. The results are in good agreement with calculations from a numerical simulator. An out-of-phase behaviour between in-core and ex-core positions was found, which is in agreement with earlier measurements from the Pressurised Water Reactor Ringhals-3. The results from these calculations are planned to be used when diagnosing the shell-mode core-barrel vibrations in an operating plant

  1. Inference of core barrel motion from neutron noise spectral density. [PWR

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, J.C.; Shahrokhi, F.; Kryter, R.C.

    1977-03-15

    A method was developed for inference of core barrel motion from the following statistical descriptors: cross-power spectral density, autopower spectral density, and amplitude probability density. To quantify the core barrel motion in a typical pressurized water reactor (PWR), a scale factor was calculated in both one- and two-dimensional geometries using forward, variational, and perturbation methods of discrete ordinates neutron transport. A procedure for selection of the proper frequency band limits for the statistical descriptors was developed. It was found that although perturbation theory is adequate for the calculation of the scale factor, two-dimensional geometric effects are important enough to rule out the use of a one-dimensional approximation for all but the crudest calculations. It was also found that contributions of gamma rays can be ignored and that the results are relatively insensitive to the cross-section set employed. The proper frequency band for the statistical descriptors is conveniently determined from the coherence and phase information from two ex-core power range neutron monitors positioned diametrically across the reactor vessel. Core barrel motion can then be quantified from the integral of the band-limited cross-power spectral density of two diametrically opposed ex-core monitors or, if the coherence between the pair is greater than or equal to 0.7, from a properly band-limited amplitude probability density function. Wide-band amplitude probability density functions were demonstrated to yield erroneous estimates for the magnitude of core barrel motion.

  2. Low-frequency noise as a diagnostic tool for OLED reliability

    NARCIS (Netherlands)

    Rocha, P.R.F.; Vandamme, L.K.J.; Meskers, S.C.J.; Gomes, H.L.; Leeuw, de D.M.; Weijer, van de P.

    2013-01-01

    Organic light emitting diodes (OLED), either based on polymers or small molecules, suffer from early failure: an unpredictable sudden increase in current with a total loss of light output. This work addresses this problem using small-signal impedance measurements and electrical noise techniques.

  3. Fast flux test facility noise data management

    International Nuclear Information System (INIS)

    Thie, J.A.

    1988-01-01

    An extensive collection of spectra from an automated data collection system at the Fast Flux Facility has features from neutron data extracted and managed by database software. Inquiry techniques, including screening, applied to database results show the influences of control rods on wideband noise and, more generally, abilities to detect diverse types of off-normal noise. Uncovering a temporary 0.1-Hz resonance shift gave additional diagnostic information on a 13-Hz mechanical motion characterized by the interference of two resonances. The latter phenomenon is discussed generically for possible application to other reactor types. (author)

  4. Aircraft Engine Noise Research and Testing at the NASA Glenn Research Center

    Science.gov (United States)

    Elliott, Dave

    2015-01-01

    The presentation will begin with a brief introduction to the NASA Glenn Research Center as well as an overview of how aircraft engine noise research fits within the organization. Some of the NASA programs and projects with noise content will be covered along with the associated goals of aircraft noise reduction. Topics covered within the noise research being presented will include noise prediction versus experimental results, along with engine fan, jet, and core noise. Details of the acoustic research conducted at NASA Glenn will include the test facilities available, recent test hardware, and data acquisition and analysis methods. Lastly some of the actual noise reduction methods investigated along with their results will be shown.

  5. Systematic classification and identification of noise spectra using perception-based neural networks

    Energy Technology Data Exchange (ETDEWEB)

    Racz, A.; Kiss, S. (KFKI-Atomic Energy Research Inst., Budapest (Hungary). Applied Reactor Physics Lab.)

    1994-01-01

    A general framework for the detection of gradually developing changes in a noise generating system is presented. The procedure is based on a new learning algorithm developed for neural networks with dynamically building architecture. The method has been tested by using almost a thousand noise spectra recorded from different detector types and from different detector positions. This work is part of a larger project, aimed at developing a noise diagnostic expert system. (author).

  6. Fuel-assembly vibration-induced neutron noise in PWRs

    International Nuclear Information System (INIS)

    Sweeney, F.J.; Renier, J.P.

    1983-01-01

    Space-dependent reactor kinetics calculations were performed to interpret observed increases in the amplitude of pressurized water reactor (PWR), ex-core neutron detector noise with increasing fuel burnup and correspondingly decreasing soluble boron concentration. These noise amplitude increases have occurred at both low frequencies (< 1.0 Hz) and in the 2.0- to 4.0-Hz frequency range. The noise amplitude increases in the 2.0- to 4.0-Hz frequency range have usually been accompanied by a decrease in the fundamental mode fuel assembly resonant frequency from 3.5 to 2.5 Hz over a fuel cycle, which has also been attributed to grid spacer spring relaxation

  7. Chamber Core Structures for Fairing Acoustic Mitigation

    National Research Council Canada - National Science Library

    Lane, Steven A; Henderson, Kyle; Williams, Andrew; Ardelean, Emil

    2007-01-01

    .... A composite chamber core fairing consists of many axial tubes sandwiched between face sheets, tubes that can be used as acoustic dampers to reduce low-frequency interior noise with virtually no added mass...

  8. Development of a noise-based method for the determination of the moderator temperature coefficient of reactivity (MTC) in pressurized water reactors (PWRs)

    International Nuclear Information System (INIS)

    Demaziere, C.

    2002-01-01

    The Moderator Temperature Coefficient of reactivity (MTC) is an important safety parameter of Pressurized Water Reactors (PWRs). In most countries, the so-called at-power MTC has to be measured a few months before the reactor outage, in order to determine if the MTC will not become too negative. Usually, the at-power MTC is determined by inducing a change in the moderator temperature, which has to be compensated for by other means, such as a change in the boron concentration. An MTC measurement using the boron dilution method is analysed in this thesis. It is demonstrated that the uncertainty of such a measurement technique is so large, that the measured MTC could become more negative than what the Technical Specifications allow. Furthermore, this technique incurs a disturbance of the plant operation. For this reason, another technique relying on noise analysis was proposed a few years ago. In this technique, the MTC is inferred from the neutron noise measured inside the core and the moderator temperature noise measured at the core-exit, in the same or in a neighbouring fuel assembly. This technique does not require any perturbation of the reactor operation, but was nevertheless proven to underestimate the MTC by a factor of 2 to 5. In this thesis, it is shown, both theoretically and experimentally, that the reason of the MTC underestimation by noise analysis is the radially loosely coupled character of the moderator temperature noise throughout the core. A new MTC noise estimator, accounting for this radially non-homogeneous moderator temperature noise is proposed and demonstrated to give the correct MTC value. This new MTC noise estimator relies on the neutron noise measured in a single point of the reactor and the radially averaged moderator temperature noise measured inside the core. In the case of the Ringhals-2 PWR in Sweden, Gamma-Thermometers (GTs) offer such a possibility since in dynamic mode they measure the moderator temperature noise, whereas in static

  9. Knowledge based diagnostics in nuclear power plants

    International Nuclear Information System (INIS)

    Baldeweg, F.; Fiedler, U.; Weiss, F.P.; Werner, M.

    1987-01-01

    In this paper a special process diagnostic system (PDS) is presented. It must be seen as the result of a long term work on computerized process surveillance and control; it includes a model based system for noise analysis of mechanical vibrations, which has recently been enhanced by using of knowledge based technique (expert systems). The paper discusses the process diagnostic frame concept and emphasize the vibration analysis expert system

  10. Stochastic aspects of two-dimensional vibration diagnostics

    International Nuclear Information System (INIS)

    Pazsit, I.; Antonopoulos-Domis, M.; Gloeckler, O.

    1985-01-01

    The aim of this paper is to investigate the stochastic features of two-dimensional lateral damped oscillations of PWR core internals, that are induced by random force components. It is also investigated how these vibrating components, or the forces giving rise to the vibrations could be diagnosed through the analysis of displacement or neutron noise signals. The approach pursued here is to select a realisation of the random force components, then the equations of the motion are integrated and the time history of displacement components is obtained. From here various statistical descriptors of the motion, such as trajectory pattern, spectra and PDF functions, etc. can be calculated. It was investigated how these statistical descriptors depend on the characteristics of the driving force for both stationary and non-stationary cases. A conclusion of possible diagnostical relevance is that, under certain circumstances, the PDF functions could be an indicator of whether a particular peak in the corresponding power spectra belongs to a resonance in system transfer or rather a resonance in the external driving force. (author)

  11. Stochastic aspects of two-dimensional vibration diagnostics

    International Nuclear Information System (INIS)

    Pazsit, I.; Antonopoulos-Domis, M.; Glockler, O.

    1984-01-01

    The aim of this paper is to investigate the stochastic features of two-dimensional lateral damped oscillations of PWR core internals that are induced by random force components. It is also investigated how these vibrating components, or the forces giving rise to the vibrations, could be diagnosed through the analysis of displacement or neutron noise signals. The approach pursued here is to select a realisation of the random force components, then the equations of the motion are integrated and the time history of displacement components is obtained. From here various statistical descriptors of the motion, such as trajectory pattern, spectra and PDF functions etc., can be calculated. It was investigated how these statistical descriptors depend on the characteristics of the driving force for both stationary and non-stationary cases. A conclusion of possible diagnostical relevance is that, under certain circumstances, the PDF functions could be an indicator of whether a particular peak in the corresponding power spectra belongs to a resonance in system transfer or rather a resonance in the external driving force

  12. Stochastic aspects of two-dimensional vibration diagnostics

    International Nuclear Information System (INIS)

    Pazsit, I.; Gloeckler, O.

    1984-01-01

    The aim of this paper is to investigate the stochastic features of two-dimensional lateral damped oscillations of PWR core internals that are induced by random force components. It is also investigated how these vibrating components, or the forces giving rise to the vibrations, could be diagnosed through the analysis of displacement or neutron noise signals. The approach pursued here is to select a realisation of the random force components, then the equations of the motion ar integrated and the time history of displacement components is obtained. From here various statistical descriptors of the motion, such as trajectory pattern, spectra and PDF functions etc., can be calculated. It was investigated how these statistical descriptors depend on the characteristics of the driving force for both stationary and non-stationary cases. A conclusion of possible diagnostical relevance is that, under certain circumstances, the PDF functions could be an indicator of whether a particular peak in the corresponding power spectra belongs to a resonance in system transfer or rather a resonance in the external driving force. (author)

  13. Coolant flow monitoring in a PWR core using noise analysis

    International Nuclear Information System (INIS)

    Kostic, Lj.

    1992-01-01

    Experimental investigations of the neutron and temperature noise field have been performed in the 1350 MW PWR nuclear power plant. Evaluation in the low frequency range, where both feedback effects and different thermohydraulics phenomena are dominant, succeeded in measuring the coolant velocity. This is important for determination and localization of essential deviations and possible anomalies. (author)

  14. Noise Prediction Module for Offset Stream Nozzles

    Science.gov (United States)

    Henderson, Brenda S.

    2011-01-01

    A Modern Design of Experiments (MDOE) analysis of data acquired for an offset stream technology was presented. The data acquisition and concept development were funded under a Supersonics NRA NNX07AC62A awarded to Dimitri Papamoschou at University of California, Irvine. The technology involved the introduction of airfoils in the fan stream of a bypass ratio (BPR) two nozzle system operated at transonic exhaust speeds. The vanes deflected the fan stream relative to the core stream and resulted in reduced sideline noise for polar angles in the peak jet noise direction. Noise prediction models were developed for a range of vane configurations. The models interface with an existing ANOPP module and can be used or future system level studies.

  15. NIF diagnostic damage and design issues

    International Nuclear Information System (INIS)

    Landen, N.

    1999-01-01

    The NIF target environment is evaluated with respect to target and diagnostic debris and with respect to instrument survivability in the presence of target debris and radiation. Quantitative estimates are arrived at by extrapolating from Nova and Omega experience using simple scaling arguments. Specifically, we evaluate the closest distance of approach of various components of DIM-based diagnostics such as target mounted pinhole arrays, open detectors, filters, x-ray optics, and spectrometers. We also include constraints on achieving adequate signal-to-noise on x-ray diagnostics. Four of the most important conclusions are as follows: (1) The required full NIF stand-off distance for heavily filtered detectors (e.g. multi-keV x-ray and particle detectors) as determined by concerns of diagnostic debris and diagnostic survivability to debris and radiation is no more than 100 cm. (2) Target mounted pinhole arrays and slits mounted a few cm from chamber center at NIF will survive long enough to record data and should be an acceptable source of shrapnel debris. (3) DIM-based instrument stand-off distances are compatible with achieving the same photon statistics (or better with ongoing improvements in detector resolution and noise) than available with current Nova and Omega SIM- or TIM-based instrumentation. Section II reviews target and diagnostic debris with respect to final optics. Section III reviews debris and radiation with respect to all diagnostic components. The following laser scaling between Nova/Omega and NIF is used throughout unless otherwise specified: laser energy E = 100x, drive duration τ = 6x and hence for a given laser intensity or hohlraum temperature, target size r approximately √(E/τ) = 4x. The 100x increase in E accounts for the fact that many Nova shots were performed with only 20 kJ and all LLNL Omega shots were performed with only 15 kJ

  16. Ambient diagnostics

    CERN Document Server

    Cai, Yang

    2014-01-01

    Part I. FundamentalsIntroductionWhat is Ambient Diagnostics?Diagnostic ModelsMultimedia IntelligenceCrowd SourcingSoft SensorsScience of SimplicityPersonal DiagnosesBasic AlgorithmsBasic ToolsSummaryProblemsTransformationEarly Discoveries of Heartbeat PatternsTransforms, Features, and AttributesSequential FeaturesSpatiotemporal FeaturesShape FeaturesImagery FeaturesFrequency Domain FeaturesMulti-Resolution FeaturesSummaryProblemsPattern RecognitionSimilarities and DistancesClustering MethodsClassification MethodsClassifier Accuracy MeasuresSummaryProblemsPart II. Multimedia IntelligenceSound RecognitionMicrophone AppsModern Acoustic Transducers (Microphones)Frequency Response CharacteristicsDigital Audio File FormatsHeart Sound SensingLung Sound SensingSnore MeterSpectrogram (STFT)Ambient Sound AnalysisSound RecognitionRecognizing Asthma SoundPeak ShiftFeature CompressionRegroupingNoise IssuesFuture ApplicationsSummaryProblemsColor SensorsColor SensingHuman Color VisionColor SensorsColor Matching ExperimentsC...

  17. Electrostatic noise measurement with a pair of spherical probes near interplanetary shocks

    International Nuclear Information System (INIS)

    Solomon, J.; Touzin, F.

    1991-01-01

    In order to obtain accurate measurements of electrostatic noise spectra on board the ISEE 1 satellite, near interplanetary shock waves, the authors perform a detailed theoretical and numerical study of an antenna consisting of a pair of spherical probes. They compute the quasi-thermal electrostatic noise observed theoretically on the antenna by assuming that the solar wind plasma can be properly represented by the sum of two Maxwellian distributions (core and halo). They study the dependence of the electrostatic spectra on the antenna length and on the different plasma parameters, particularly on the density and temperature ratio of the core and of the halo. They show that by also taking into account the instrumental noise and the shot noise on the antenna, a calibration factor can be precisely determined for the antenna that they consider. They display some results obtained from measurements of electrostatic noise spectra behind interplanetary shock waves. Finally, they discuss the real meaning of a specific halo temperature, and they show that, in a first approximation, the theoretical results are only slightly modified when they consider types of distributions other than Maxwellians

  18. Utilization of noise analysis technique for mechanical vibrations estimation in the ATUCHA1 and Embalse Argentine NPP

    International Nuclear Information System (INIS)

    Lescano, V.H.; Wentzeis, L.M.; Guevara, M.; Moreno, C.; Pineyro, J.

    1996-01-01

    In Argentine, comprehensive noise measurements have been performed with the reactor instrumentation of the PHWR power plant Atucha I and Embalse. The Embalse reactor is a CANDU-600 (600 Mwe) type pressurized heavy water reactor. It's a heavy water moderator and heavy water cooled natural uranium fueled pressure tube system. Signal of vanadium and platinum type in core-self power neutron detectors of ex-core ion chambers and of a moderator pressure sensor have been recorded and analysed. The vibration of reactor internals as vertical and horizontal in-core neutron flux detectors units and the coolant channels systems, consisting of calandria and pressure tubes with fuel bundles, have been identified and monitored during normal reactor operation. Atucha I, is a PHWR reactor natural uranium fueled, and heavy water moderated and cooled. Neutron noise techniques using of ex-core ionization chambers and in-core Vanadium SPND's were implemented, among others, in order to produce early detection of anomalous vibrations in the reactor internals. Noise analysis was successfully performed to identify normal and peculiar vibrations in particular reactor internals. (author)

  19. On the determination of boiling water reactor characteristics by noise analysis

    International Nuclear Information System (INIS)

    Kleiss, J.

    1983-01-01

    In boiling water reactors the main noise source is the boiling process in the core and the most important variable is the neutron flux, thus the effect of the steam bubbles on the neutron flux is studied in detail. An experiment has been performed in a small subcritical reactor to measure the response of a neutron detector to the passage of a single air bubble. A mathematical model for the description of the response was tested and the results agree very well with the experiment. Noise measurements in the Dodewaard boiling water reactor are discussed. The construction of a twin self-powered neutron detector, developed to perform steam velocity measurements in the core is described. The low-frequency part of the neutron noise characteristics is considered. The transfer functions exhibit a good agreement with ones obtained by independent means: control rod step experiments and model calculations. (Auth.)

  20. The diagnostic ability of an additional midline peripheral zone biopsy in transrectal ultrasonography-guided 12-core prostate biopsy to detect midline prostate cancer

    Directory of Open Access Journals (Sweden)

    Inpyeong Hwang

    2016-01-01

    Full Text Available Purpose: The goal of this study was to evaluate the diagnostic effect of adding a midline peripheral zone (PZ biopsy to the 12-core biopsy protocol used to diagnose prostate cancer (PC, and to assess the clinical and pathologic characteristics of midline-positive PC in order to identify a potential subgroup of patients who would require midline PZ biopsy. Methods: This study included 741 consecutive patients who underwent a transrectal ultrasonography-guided, 12-core prostate biopsy with an additional midline core biopsy between October 2012 and December 2013. We grouped patients by the presence or absence of PC and subdivided patients with PC based on the involvement of the midline core. The clinical characteristics of these groups were compared, including serum prostate-specific antigen (PSA concentrations, PSA density, and pathological features in the biopsy specimens. Results: PC was detected in 289 patients (39.0%. Among the PC patients, 66 patients (22.8% had midline PC. No patients were diagnosed with PC based only on a midline core. The Gleason scores, number of positive cores, tumor core length, serum PSA concentrations, and PSA density were significantly higher in patients with midline-positive PC (P<0.001. Furthermore, significant cancer was more frequent in the midline-positive group (98.5% vs. 78.0%. Conclusion: Patients showing a positive result for PC in a midline PZ biopsy were more likely to have multiple tumors or large-volume PC with a high tumor burden. However, our data indicated that an additional midline core biopsy is unlikely to be helpful in detecting occult midline PC.

  1. Noise diagnostics research at the Institute for Electric Power Research

    International Nuclear Information System (INIS)

    Voeroess, L.

    1983-01-01

    The main goal of recent research is the designing of a diagnostic system for the Paks nuclear power plant. It includes the designing of measuring cascades for measuring mechanical vibrations caused by flow and pressure fluctuations in the primary coolant circuit, the arrangement of measuring cascades for measuring turbine bearing vibrations in the secondary coolant circuit, and the development, manufacturing and commissioning of a central data acquisition and processing unit for the whole diagnostic system. Simultaneously computer models are developed for improving the interpretation. Moreover, it is planned to develop methods for estimating residual lifetime and the status of plant components. (author)

  2. Noise analysis of the Dodewaard boiling water reactor: characteristics and time history

    International Nuclear Information System (INIS)

    Veer, J.H.C. v.d.; Kema, N.V.

    1982-01-01

    Reactor noise measurements have been performed in the Dodewaard BWR since the eighth fuel cycle (1978). Analysis of the noise characteristics of the ex-core neutron detectors are reported. As a result characteristics of the global component of the boiling noise and the influence of oscillatory effects in reactor pressure control and steam flow rate are described. The influence of power feedback effects on the detection of global noise at low frequencies is given using point kinetic reactor theory. Results are reported on the behaviour of the neutron noise characteristics during one fuel cycle and on the behaviour from fuel cycle 8 to 11. (author)

  3. Design advances of the Core Plasma Thomson Scattering diagnostic for ITER.

    Czech Academy of Sciences Publication Activity Database

    Scannell, R.; Maslov, M.; Naylor, G.; O’Gorman, T.; Kempenaars, M.; Carr, M.; Bílková, Petra; Böhm, Petr; Giudicotti, L.; Pasqualotto, R.; Bassan, M.; Vayakis, G.; Walsh, M.; Huxford, R.

    2017-01-01

    Roč. 12, November (2017), č. článku C11010. ISSN 1748-0221. [International Symposium on Laser-Aided Plasma Diagnostics (LAPD2017) /18./. Prague, 24.09.2017-28.09.2017] Institutional support: RVO:61389021 Keywords : Nuclear instruments and methods for hot plasma diagnostics * Plasma diagnostics - interferometry * spectroscopy and imaging Subject RIV: BL - Plasma and Gas Discharge Physics OBOR OECD: 2.11 Other engineering and technologies Impact factor: 1.220, year: 2016 http://iopscience.iop.org/article/10.1088/1748-0221/12/11/C11010/pdf

  4. Molecular Diagnostics of the Internal Motions of Massive Cores

    Science.gov (United States)

    Pineda, Jorge; Velusamy, T.; Goldsmith, P.; Li, D.; Peng, R.; Langer, W.

    2009-12-01

    We present models of the internal kinematics of massive cores in the Orion molecular cloud. We use a sample of cores studied by Velusamy et al. (2008) that show red, blue, and no asymmetry in their HCO+ line profiles in equal proportion, and which therefore may represent a sample of cores in different kinematic states. We use the radiative transfer code RATRAN (Hogerheijde & van der Tak 2000) to model several transitions of HCO+ and H13CO+ as well as the dust continuum emission, of a spherical model cloud with radial density, temperature, and velocity gradients. We find that an excitation and velocity gradients are prerequisites to reproduce the observed line profiles. We use the dust continuum emission to constrain the density and temperature gradients. This allows us to narrow down the functional forms of the velocity gradient giving us the opportunity to test several theoretical predictions of velocity gradients produced by the effect of magnetic fields (e.g. Tassis et. al. 2007) and turbulence (e.g. Vasquez-Semanedi et al 2007).

  5. Analysis and development of deterministic and stochastic neutron noise computing techniques with applications to thermal and fast reactors

    International Nuclear Information System (INIS)

    Rouchon, Amelie

    2016-01-01

    Neutron noise analysis addresses the description of small time-dependent flux fluctuations induced by small global or local perturbations of the macroscopic cross-sections. These fluctuations may occur in nuclear reactors due to density fluctuations of the coolant, to vibrations of fuel elements, control rods, or any other structures in the core. In power reactors, ex-core and in-core detectors can be used to monitor neutron noise with the aim of detecting possible anomalies and taking the necessary measures for continuous safe power production. The objective of this thesis is to develop techniques for neutron noise analysis and especially to implement a neutron noise solver in the deterministic transport code APOLLO3 developed at CEA. A new Monte Carlo algorithm that solves the transport equations for the neutron noise has been also developed. In addition, a new vibration model has been developed. Moreover, a method based on the determination of a new steady state has been proposed for the linear and the nonlinear full theory so as to improve the traditional neutron noise theory. In order to test these new developments we have performed neutron noise simulations in one-dimensional systems and in a large pressurized water reactor with heavy baffle in two and three dimensions with APOLLO3 in diffusion and transport theories. (author) [fr

  6. Fission-powered in-core thermoacoustic sensor

    Energy Technology Data Exchange (ETDEWEB)

    Garrett, Steven L. [Graduate Program in Acoustics, Penn State University, University Park, Pennsylvania 16802 (United States); Smith, James A. [Fundamental Fuel Properties, Idaho National Laboratory, Idaho Falls, Idaho 83415 (United States); Smith, Robert W. M. [Applied Research Laboratory, Penn State University, State College, Pennsylvania 16804 (United States); Heidrich, Brenden J. [Nuclear Science User Facilities, Idaho National Laboratory, Idaho Falls, Idaho 83415 (United States); Heibel, Michael D. [Global Technology Development, Westinghouse Electric Company, Cranberry Township, Pennsylvania 16066 (United States)

    2016-04-04

    A thermoacoustic engine is operated within the core of a nuclear reactor to acoustically telemeter coolant temperature (frequency-encoded) and reactor power level (amplitude-encoded) outside the reactor, thus providing the values of these important parameters without external electrical power or wiring. We present data from two hydrophones in the coolant (far from the core) and an accelerometer attached to a structure outside the reactor. These signals have been detected even in the presence of substantial background noise generated by the reactor's fluid pumps.

  7. An ultra low noise AC beam transformer for deceleration and diagnostics of low intensity beams

    CERN Document Server

    González, C

    1999-01-01

    The design of a broad band ultra-low noise ferrite loaded AC beam transformer is presented. It is designed for use in the CERN Antiproton Decelerator (AD), where beams of a few 107 charges must be decelerated from 3.5 GeV/c to 100 MeV/c. It is used in the RF beam-phase loop, and for intensity and bunch shape measurements during deceleration. When the beam is debunched for cooling on magnetic flat tops, the pick-up is used for measurements of intensity and momentum distribution by means of longitudinal Schottky scans. When used as Schottky pick-up, the signal to noise ratio should be better by about 40 dB than the existing stripline based longitudinal Schottky pick-up. The integrated design of pick-up and associated low-noise amplifier is presented. The achieved noise performance of a few from 1 to 3 MHz is obtained by attaching a low-noise, high-impedance silicon JFET (junction field effect transistor) amplifier to a high-Q resonant ferrite loaded cavity, and then eliminating the resonant response by low-nois...

  8. Diagnostic system for primary circuits of pressurized-water reactors

    International Nuclear Information System (INIS)

    Liska, J.; Majer, J.

    1983-01-01

    The diagnostic system monitors the reactor, the main circulating pipe, the main circulating pump, the main shut-off valve, the steam generator and the pressurizer. Diagnostic signals are obtained from the sensors designed for operation measurements and from sensors for special diagnostic purposes. The following operations are carried out: detection of dangerous dynamic stress of components, detection of damage to functional surfaces of components, detection of occurrence and propagation of defects in component materials, detection of loose particles and foreign bodies, detection of coolant leakage, detection of coolant boiling in the core and detection of impermissible non-homogeneities of fields of physical quantities in the core. The diagnostic system comprises: monitoring, classification of properly investigated effects, periodical tracing and long-term tracing. The operational diagnostics system developed by the SKODA Concern consists of a vibration monitoring system, a spectral analysis system and a central evaluation system. (M.D.)

  9. Separated core turbofan engine; Core bunrigata turbofan engine

    Energy Technology Data Exchange (ETDEWEB)

    Saito, Y; Endo, M; Matsuda, Y; Sugiyama, N; Sugahara, N; Yamamoto, K [National Aerospace Laboratory, Tokyo (Japan)

    1996-04-01

    This report outlines the separated core turbofan engine. This engine is featured by parallel separated arrangement of a fan and core engine which are integrated into one unit in the conventional turbofan engine. In general, cruising efficiency improvement and noise reduction are achieved by low fan pressure ratio and low exhaust speed due to high bypass ratio, however, it causes various problems such as large fan and nacelle weight due to large air flow rate of a fan, and shift of an operating point affected by flight speed. The parallel separated arrangement is thus adopted. The stable operation of a fan and core engine is easily retained by independently operating air inlet unaffected by fan. The large degree of freedom of combustion control is also obtained by independent combustor. Fast response, simple structure and optimum aerodynamic design are easily achieved. This arrangement is also featured by flexibility of development and easy maintenance, and by various merits superior to conventional turbofan engines. It has no technological problems difficult to be overcome, and is also suitable for high-speed VTOL transport aircraft. 4 refs., 5 figs.

  10. Development of Lightweight, Compact, Structurally-Integrated Acoustic Liners for Broadband Low-Frequency Noise Mitigation

    Science.gov (United States)

    Chambers, Andrew T.

    Airborne noise with a low dominant frequency content (scope of conventional acoustic noise mitigation techniques using liners, foams or claddings owing to mass and volume considerations. Its low evanescence contributes significantly to environmental noise pollution, and unwanted structural vibrations causing diminished efficiency, comfort, payload integrity and mission capabilities. An alternative approach using liner configurations with realistic mass and volume constraints having innovative 'folded' core geometries is investigated to ascertain its low-frequency noise absorption characteristics. In contrast to mass-driven approaches, the folded core approach relies on tailoring interactions between acoustic resonances to tune the liner's impedance to suit the dominant low-frequency content of the source. This allows to keep non-structural mass-addition to a minimum, while retaining an overall thickness comparable to conventional liners for these low-frequency liner designs. The relative acoustic performance of various candidate folded core designs is evaluated by means of a new composite metric termed the Low-Frequency Performance (LFP) factor, which is educed from the absorption coefficient spectrum obtained using Zwikker-Kosten Transmission Line (ZKTL) theory-based numerical studies. An LFP-based software tool is developed to determine optimal 3D cavity packing for a prescribed liner volume and target frequency range. ZKTL-based parametric studies on core dimensions and face sheet porosity are utilized for detailed design of test articles. Experimental verification of absorption coefficient spectra conducted using 3D printed test articles in a normal incidence acoustic impedance tube yield good correlation with simulations. More than 100 Hz of continuous bandwidth with an absorption coefficient greater than 0.6 is shown to be possible in the 300 to 400 Hz range with a 38.1-mm (1.5-inch) thick liner. Further, the influence of face sheet type, Mach number, and

  11. Sensor response time monitoring using noise analysis

    International Nuclear Information System (INIS)

    Hashemian, H.M.; Thie, J.A.; Upadhyaya, B.R.; Holbert, K.E.

    1988-01-01

    Random noise techniques in nuclear power plants have been developed for system surveillance and for analysis of reactor core dynamics. The noise signals also contain information about sensor dynamics, and this can be extracted using frequency, amplitude and time domain analyses. Even though noise analysis has been used for sensor response time testing in some nuclear power plants, an adequate validation of this method has never been carried out. This paper presents the results of limited work recently performed to examine the validity of the noise analysis for sensor response time testing in nuclear power plants. The conclusion is that noise analysis has the potential for detecting gross changes in sensor response but it cannot be used for reliable measurement of response time until more laboratory and field experience is accumulated. The method is more advantageous for testing pressure sensors than it is for temperature sensors. This is because: 1) for temperature sensors, a method called Loop Current Step Response test is available which is quantitatively more exact than noise analysis, 2) no method currently exists for on-line testing of pressure transmitters other than the Power-Interrupt test which is applicable only to force balance pressure transmitters, and 3) pressure sensor response time is affected by sensing line degradation which is inherently taken into account by testing with noise analysis. (author)

  12. On the shock cell structure and noise of supersonic jets

    Science.gov (United States)

    Tam, C. K. W.; Jackson, J. A.

    1983-01-01

    A linear solution modeling the shock cell structure of an axisymmetric supersonic jet operated at off-design conditions is developed by the method of multiple-scales. The model solution takes into account the gradual spatial change of the mean flow in the downstream direction. Turbulence in the mixing layer of the jet has the tendency of smoothing out the sharp velocity and density gradients induced by the shocks. To simulate this effect, eddy viscosity terms are incorporated in the model. It is known that the interaction between the quasi-periodic shock cells and the downstream propagating large turbulence structures in the mixing layer of the jet is responsible for the generation of broadband shock associated noise. Experimentally, the dominant part of this noise has been found to originate from the part of the jet near the end of the potential core. Calculated shock cell spacing at the end of the jet core according to the present model is used to estimate the peak frequencies of the shock associated noise for a range of observation angles. Very favorable agreement with experimental measurements is found.

  13. Diagnostic accuracy of semi-automatic quantitative metrics as an alternative to expert reading of CT myocardial perfusion in the CORE320 study.

    Science.gov (United States)

    Ostovaneh, Mohammad R; Vavere, Andrea L; Mehra, Vishal C; Kofoed, Klaus F; Matheson, Matthew B; Arbab-Zadeh, Armin; Fujisawa, Yasuko; Schuijf, Joanne D; Rochitte, Carlos E; Scholte, Arthur J; Kitagawa, Kakuya; Dewey, Marc; Cox, Christopher; DiCarli, Marcelo F; George, Richard T; Lima, Joao A C

    2018-04-03

    To determine the diagnostic accuracy of semi-automatic quantitative metrics compared to expert reading for interpretation of computed tomography perfusion (CTP) imaging. The CORE320 multicenter diagnostic accuracy clinical study enrolled patients between 45 and 85 years of age who were clinically referred for invasive coronary angiography (ICA). Computed tomography angiography (CTA), CTP, single photon emission computed tomography (SPECT), and ICA images were interpreted manually in blinded core laboratories by two experienced readers. Additionally, eight quantitative CTP metrics as continuous values were computed semi-automatically from myocardial and blood attenuation and were combined using logistic regression to derive a final quantitative CTP metric score. For the reference standard, hemodynamically significant coronary artery disease (CAD) was defined as a quantitative ICA stenosis of 50% or greater and a corresponding perfusion defect by SPECT. Diagnostic accuracy was determined by area under the receiver operating characteristic curve (AUC). Of the total 377 included patients, 66% were male, median age was 62 (IQR: 56, 68) years, and 27% had prior myocardial infarction. In patient based analysis, the AUC (95% CI) for combined CTA-CTP expert reading and combined CTA-CTP semi-automatic quantitative metrics was 0.87(0.84-0.91) and 0.86 (0.83-0.9), respectively. In vessel based analyses the AUC's were 0.85 (0.82-0.88) and 0.84 (0.81-0.87), respectively. No significant difference in AUC was found between combined CTA-CTP expert reading and CTA-CTP semi-automatic quantitative metrics in patient based or vessel based analyses(p > 0.05 for all). Combined CTA-CTP semi-automatic quantitative metrics is as accurate as CTA-CTP expert reading to detect hemodynamically significant CAD. Copyright © 2018 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  14. Determination of fuel assembly vibrational modes through analysis of incore detector noise

    International Nuclear Information System (INIS)

    Johnson, R.S.

    1986-01-01

    In order to better characterize fuel assembly vibration at Duke Power Company's Oconee Nuclear Station, incore noise data were acquired an analyzed from prompt responding detectors incorporated in the Oconee 2, Cycle 7 core. Duke Power Company began actively pursuing an inhouse Neutron Noise Analysis program for routine surveillance of reactor internals vibration in 1979. Noise data has since been acquired and analyzed for twelve cycles of operation for the three Oconee units. Duke Power's Oconee Unit 2 is a Babcock and Wilcoxs pressurized water reactor with a rate thermal power of 2568MW. For Oconee 2, Cycle 7 operation, two test assemblies, each employing a string of seven axially-spaced, prompt responding hafnium detectors, were included in the final core design. Incore detector noise data were obtained during Cycle 7 at approximately 281 and 430 effective full power days (EFPD). In addition to the incore test detector signals, noise signals from the upper and lower chambers of the four excore power range detectors were recorded to aid in the analysis. The comparison of RMS signal levels for each incore detector and the phase relationships between detector locations within two test assemblies identified the first four fuel assembly bending modes associated with fixed end conditions

  15. A noise-optimized virtual monochromatic reconstruction algorithm improves stent visualization and diagnostic accuracy for detection of in-stent re-stenosis in lower extremity run-off CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Mangold, Stefanie [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Eberhard-Karls University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); De Cecco, Carlo N.; Yamada, Ricardo T.; Varga-Szemes, Akos; Stubenrauch, Andrew C.; Fuller, Stephen R. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Schoepf, U.J. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States); Caruso, Damiano [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); University of Rome ' ' Sapienza' ' , Department of Radiological Sciences, Oncology and Pathology, Rome (Italy); Vogl, Thomas J.; Wichmann, Julian L. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Nikolaou, Konstantin [Eberhard-Karls University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Todoran, Thomas M. [Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States)

    2016-12-15

    To evaluate the impact of noise-optimized virtual monochromatic imaging (VMI+) on stent visualization and accuracy for in-stent re-stenosis at lower extremity dual-energy CT angiography (DE-CTA). We evaluated third-generation dual-source DE-CTA studies in 31 patients with prior stent placement. Images were reconstructed with linear blending (F{sub 0}.5) and VMI+ at 40-150 keV. In-stent luminal diameter was measured and contrast-to-noise ratio (CNR) calculated. Diagnostic confidence was determined using a five-point scale. In 21 patients with invasive catheter angiography, accuracy for significant re-stenosis (≥50 %) was assessed at F{sub 0}.5 and 80 keV-VMI+ chosen as the optimal energy level based on image-quality analysis. At CTA, 45 stents were present. DSA was available for 28 stents whereas 12 stents showed significant re-stenosis. CNR was significantly higher with ≤80 keV-VMI+ (17.9 ± 6.4-33.7 ± 12.3) compared to F{sub 0}.5 (16.9 ± 4.8; all p < 0.0463); luminal stent diameters were increased at ≥70 keV (5.41 ± 1.8-5.92 ± 1.7 vs. 5.27 ± 1.8, all p < 0.001) and diagnostic confidence was highest at 70-80 keV-VMI+ (4.90 ± 0.48-4.88 ± 0.63 vs. 4.60 ± 0.66, p = 0.001, 0.0042). Sensitivity, negative predictive value and accuracy for re-stenosis were higher with 80 keV-VMI+ (100, 100, 96.4 %) than F{sub 0}.5 (90.9, 94.1, 89.3 %). 80 keV-VMI+ improves image quality, diagnostic confidence and accuracy for stent evaluation at lower extremity DE-CTA. (orig.)

  16. Vibration mode and vibration shape under excitation of a three phase model transformer core

    Science.gov (United States)

    Okabe, Seiji; Ishigaki, Yusuke; Omura, Takeshi

    2018-04-01

    Structural vibration characteristics and vibration shapes under three-phase excitation of a archetype transformer core were investigated to consider their influences on transformer noise. Acoustic noise and vibration behavior were measured in a three-limb model transformer core. Experimental modal analysis by impact test was performed. The vibration shapes were measured by a laser scanning vibrometer at different exciting frequencies. Vibration amplitude of the core in out-of-plane direction were relatively larger than those in other two in-plane directions. It was consistent with the result that the frequency response function of the core in out-of-plane direction was larger by about 20 dB or more than those in in-plane directions. There were many vibration modes having bending deformation of limbs in out-of-plane direction. The vibration shapes of the core when excited at 50 Hz and 60 Hz were almost the same because the fundamental frequencies of the vibration were not close to the resonance frequencies. When excitation frequency was 69 Hz which was half of one of the resonance frequencies, the vibration shape changed to the one similar to the resonance vibration mode. Existence of many vibration modes in out-of-plane direction of the core was presumed to be a reason why frequency characteristics of magnetostriction and transformer noise do not coincide.

  17. Investigation and measures to noise on spectroscopic measurement system in JT-60U

    International Nuclear Information System (INIS)

    Nagaya, Susumu; Kubo, Hirotaka; Sugie, Tatsuo; Onizawa, Masami; Kawai, Isao; Nakata, Hisao.

    1997-11-01

    Breakdown of a negative-ion-based neutral beam injection (N-NBI) has caused noise trouble to several systems. The control circuit of a spectroscopic measurement system had not well worked because of the noise. The noise has been measured by an optical-fiber isolation system during operation of JT-60U. The amplitude and the frequency were 15-18 V and 15 MHz respectively. The transmission noise has been reduced by putting ferrite cores to all cables connecting with the control circuits. As a result, the trouble with the spectroscopic measurement system has completely been solved. Adding condensers and resistors to the circuit was not effective to reduce the noise. (author)

  18. 18th informal meeting on reactor noise

    International Nuclear Information System (INIS)

    Dach, K.

    1986-01-01

    The proceedings contain the texts of 24 papers all of which fall under the INIS Subject Scope. The main purpose of the meeting of more than 90 scientists and specialists from 18 countries was for them to get acquainted with the current state and prospective development of noise diagnostics application in nuclear reactor operation. (Z.M.)

  19. Prompt neutron decay constant estimation of RSG-GAS at high power noise experiment

    International Nuclear Information System (INIS)

    Jujuratisbela, U.; Kristedjo; Tukiran; Pinem, S.; Iman, J.; Puryono; Sanjaya, A.; Suwarno

    1998-01-01

    The determination of prompt neutron decay constant (α) of RGS-GAS by using low power noise experiment method at the equilibrium core indicated that the result is not good. The bad result was due to the small ratio of the noise signal to background which was caused by low detector efficiency or contaminated core after long time operation. To solve the problem is tried by using noise experiment technique at high power. The voltage output of neutron detectors at power of 5, 12, and 23 MW were connected to preamplifier and filter then to the Dynamic Signal Analyzer Version-2 and then the power spectral density of each channel of JKT04 and JKT03, the cut off frequency of each channel can be determined by using linear regression technique such that the prompt neutron decay constant can be estimated

  20. Study of the noise propagation in PWR with coupled codes

    International Nuclear Information System (INIS)

    Verdu, G.; Garcia-Fenoll, M.; Abarca, A.; Miro, R.; Barrachina, T.

    2011-01-01

    The in-core detectors provide signals of the power distribution monitoring for the Reactor Protection System (RPS). The advanced fuel management strategies (high exposure) and the power upratings for PWR reactor types have led to an increase in the noise amplitude in detectors signals. In the present work a study of the propagation along the reactor core and the effects on the core power evolution of a small perturbation on the moderator density, using the coupled code RELAP5-MOD3.3/PARCSv2.7 is presented. The purpose of these studies is to be able to reproduce and analyze the in-core detector simulated signals. (author)

  1. Edge diagnostics for tandem mirror machines

    International Nuclear Information System (INIS)

    Allen, S.L.

    1984-01-01

    The edge plasma in a tandem mirror machine shields the plasma core from cold neutral gas and impurities. A variety of diagnostics are used to measure the fueling, shielding, and confinement of the edge plasma in both the end plug and central cell regions. Fast ion gauges and residual gas analyzers measure the gas pressure and composition outside of the plasma. An array of Langmuir probes is used to measure the electron density and temperature. Extreme ultraviolet (euv) and visible spectroscopy are used to measure both the impurity and deuterium densities and to estimate the shielding factor for the core plasma. The linear geometry of a tandem mirror also allows direct measurements of the edge plasma by sampling the ions and electrons lost but the ends of the machine. Representative data obtained by these diagnostics during operation of the Tandem Mirror Experiment (TMX) and Tandem Mirror Experiment-Upgrade (TMX-U) experiments are presented. Diagnostics that are currently being developed to diagnose the edge plasma are also discussed

  2. Advanced Low-Noise Research Fan Stage Design

    Science.gov (United States)

    Neubert, Robert; Bock, Larry; Malmborg, Eric; Owen-Peer, William

    1997-01-01

    This report describes the design of the Advanced Low-Noise Research Fan stage. The fan is a variable pitch design, which is designed at the cruise pitch condition. Relative to the cruise setting, the blade is closed at takeoff and opened for reverse thrust operation. The fan stage is a split flow design with fan exit guide vanes (FEGVs) and core stators. The fan stage design is combined with a nacelle and engine core duct to form a powered fan/nacelle subscale model. This model is intended for use in combined aerodynamic, acoustic, and structural testing in a wind tunnel. The fan has an outer diameter of 22 in. and a hub-to-tip of 0.426 in., which allows the use of existing NASA fan and cowl force balance and rig drive systems. The design parameters were selected to permit valid acoustic and aerodynamic comparisons with the Pratt & Whitney (P&W) 17- and 22-in. rigs previously tested under NASA contract. The fan stage design is described in detail. The results of the design axisymmetric and Navier-Stokes aerodynamic analysis are presented at the critical design conditions. The structural analysis of the fan rotor and attachment is included. The blade and attachment are predicted to have adequate low-cycle fatigue life and an acceptable operating range without resonant stress or flutter. The stage was acoustically designed with airfoil counts in the FEGV and core stator to minimize noise. A fan/FEGV tone analysis developed separately under NASA contract was used to determine the optimum airfoil counts. The fan stage was matched to the existing nacelle, designed under the previous P&W low-noise contract, to form a fan/nacelle model for wind tunnel testing. It is an axisymmetric nacelle for convenience in testing and analysis. Previous testing confirmed that the nacelle performed as required at various aircraft operating conditions.

  3. Broadband Shock Noise in Internally-Mixed Dual-Stream Jets

    Science.gov (United States)

    Bridges, James E.

    2009-01-01

    Broadband shock noise (BBSN) has been studied in some detail in single-flow jets and recently in dual-stream jets with separate flow exhaust systems. Shock noise is of great concern in these latter cases because of the noise created for the aircraft cabin by the underexpanded nozzle flow at cruise. Another case where shock noise is of concern is in the case of future supersonic aircraft that are expected to have bypass ratios small enough to justify internally mixed exhaust systems, and whose mission will push cycles to the point of imperfectly expanded flows. Dual-stream jets with internally mixed plume have some simplifying aspects relative to the separate flow jets, having a single shock structure given by the common nozzle pressure. This is used to separate the contribution of the turbulent shear layer to the broadband shock noise. Shock structure is held constant while the geometry and strength of the inner and merged shear layers are varying by changing splitter area ratio and core stream temperature. Flow and noise measurements are presented which document the efforts at separating the contribution of the inner shear layer to the broadband shock noise.

  4. Correlation ECE diagnostic in Alcator C-Mod

    International Nuclear Information System (INIS)

    Sung, C.; Irby, J.; Leccacorvi, R.; Vieira, R.; Oi, C.; Rice, J.; Reinke, M.; Gao, C.; Ennever, P.; Porkolab, M.; Churchill, R.; Theiler, C.; Walk, J.; Hughes, J.; Hubbard, A.; Greenwald, M.

    2015-01-01

    Correlation ECE (CECE) is a diagnostic technique that allows measurement of small amplitude electron temperature, Te, fluctuations through standard cross-correlation analysis methods. In Alcator C-Mod, a new CECE diagnostic has been installed[Sung RSI 2012], and interesting phenomena have been observed in various plasma conditions. We find that local Te fluctuations near the edge (ρ ~ 0:8) decrease across the linearto- saturated ohmic confinement transition, with fluctuations decreasing with increasing plasma density [Sung NF 2013], which occurs simultaneously with rotation reversals [Rice NF 2011]. Te fluctuations are also reduced across core rotation reversals with an increase of plasma density in RF heated L-mode plasmas, which implies that the same physics related to the reduction of Te fluctuations may be applied to both ohmic and RF heated L-mode plasmas. In I-mode plasmas, we observe the reduction of core Te fluctuations, which indicates changes of turbulence occur not only in the pedestal region but also in the core across the L/I transition [White NF 2014]. The present CECE diagnostic system in C-Mod and these experimental results are described in this paper

  5. Reactor noise analysis of experimental fast reactor 'JOYO'

    International Nuclear Information System (INIS)

    Ohtani, Hideji; Yamamoto, Hisashi

    1980-01-01

    As a part of dynamics tests in experimental fast reactor ''JOYO'', reactor noise tests were carried out. The reactor noise analysis techniques are effective for study of plant characteristics by determining fluctuations of process signals (neutron signal, reactor inlet temperature signals, etc.), which are able to be measured without disturbances for reactor operations. The aims of reactor noise tests were to confirm that no unstable phenomenon exists in ''JOYO'' and to gain initial data of the plant for reference of the future data. Data for the reactor noise tests treated in this paper were obtained at 50 MW power level. Fluctuations of process signals were amplified and recorded on analogue tapes. The analysis was performed using noise code (NOISA) of digital computer, with which statistical values of ASPD (auto power spectral density), CPSD (cross power spectral density), and CF (coherence function) were calculated. The primary points of the results are as follows. 1. RMS value of neutron signal at 50 MW power level is about 0.03 MW. This neutron fluctuation is not disturbing reactor operations. 2. The fluctuations of A loop reactor inlet temperatures (T sub(AI)) are larger than the fluctuations of B loop reactor inlet temperature (T sub(BI)). For this reason, the major driving force of neutron fluctuations seems to be the fluctuations of T sub(AI). 3. Core and blanket subassemblies can be divided into two halves (A and B region), with respect to the spacial motion of temperature in the reactor core. A or B region means the region in which sodium temperature fluctuations in subassembly are significantly affected by T sub(AI) or T sub(BI), respectively. This phenomenon seems to be due to the lack of mixing of A and B loop sodium in lower plenum of reactor vessel. (author)

  6. Tomographic capabilities of the new GEM based SXR diagnostic of WEST

    Science.gov (United States)

    Jardin, A.; Mazon, D.; O'Mullane, M.; Mlynar, J.; Loffelmann, V.; Imrisek, M.; Chernyshova, M.; Czarski, T.; Kasprowicz, G.; Wojenski, A.; Bourdelle, C.; Malard, P.

    2016-07-01

    The tokamak WEST (Tungsten Environment in Steady-State Tokamak) will start operating by the end of 2016 as a test bed for the ITER divertor components in long pulse operation. In this context, radiative cooling of heavy impurities like tungsten (W) in the Soft X-ray (SXR) range [0.1 keV; 20 keV] is a critical issue for the plasma core performances. Thus reliable tools are required to monitor the local impurity density and avoid W accumulation. The WEST SXR diagnostic will be equipped with two new GEM (Gas Electron Multiplier) based poloidal cameras allowing to perform 2D tomographic reconstructions in tunable energy bands. In this paper tomographic capabilities of the Minimum Fisher Information (MFI) algorithm developed for Tore Supra and upgraded for WEST are investigated, in particular through a set of emissivity phantoms and the standard WEST scenario including reconstruction errors, influence of noise as well as computational time.

  7. Methods to characterize non-Gaussian noise in TAMA

    International Nuclear Information System (INIS)

    Ando, Masaki; Arai, K; Takahashi, R; Tatsumi, D; Beyersdorf, P; Kawamura, S; Miyoki, S; Mio, N; Moriwaki, S; Numata, K; Kanda, N; Aso, Y; Fujimoto, M-K; Tsubono, K; Kuroda, K

    2003-01-01

    We present a data characterization method for the main output signal of the interferometric gravitational-wave detector, in particular targeting at effective detection of burst gravitational waves from stellar core collapse. The time scale of non-Gaussian events is evaluated in this method, and events with longer time scale than real signals are rejected as non-Gaussian noises. As a result of data analysis using 1000 h of real data with the interferometric gravitational-wave detector TAMA300, the false-alarm rate was improved 10 3 times with this non-Gaussian noise evaluation and rejection method

  8. RANS Analyses of Turbofan Nozzles with Internal Wedge Deflectors for Noise Reduction

    Science.gov (United States)

    DeBonis, James R.

    2009-01-01

    Computational fluid dynamics (CFD) was used to evaluate the flow field and thrust performance of a promising concept for reducing the noise at take-off of dual-stream turbofan nozzles. The concept, offset stream technology, reduces the jet noise observed on the ground by diverting (offsetting) a portion of the fan flow below the core flow, thickening and lengthening this layer between the high-velocity core flow and the ground observers. In this study a wedge placed in the internal fan stream is used as the diverter. Wind, a Reynolds averaged Navier-Stokes (RANS) code, was used to analyze the flow field of the exhaust plume and to calculate nozzle performance. Results showed that the wedge diverts all of the fan flow to the lower side of the nozzle, and the turbulent kinetic energy on the observer side of the nozzle is reduced. This reduction in turbulent kinetic energy should correspond to a reduction in noise. However, because all of the fan flow is diverted, the upper portion of the core flow is exposed to the freestream, and the turbulent kinetic energy on the upper side of the nozzle is increased, creating an unintended noise source. The blockage due to the wedge reduces the fan mass flow proportional to its blockage, and the overall thrust is consequently reduced. The CFD predictions are in very good agreement with experimental flow field data, demonstrating that RANS CFD can accurately predict the velocity and turbulent kinetic energy fields. While this initial design of a large scale wedge nozzle did not meet noise reduction or thrust goals, this study identified areas for improvement and demonstrated that RANS CFD can be used to improve the concept.

  9. CT Fluoroscopy-Guided Core Biopsy for Diagnosis of Small ({<=} 20 mm) Pulmonary Nodules

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hye Larn; Kim, Yoon Kyung; Woo, Ok Hee; Yong, Hwan Seok; Kang, Eun Young [Dept. of Radiology, Korea University Guro Hospital, Korea University College of Medicine, Seoul (Korea, Republic of); Kim, Hyun Koo [Dept. of Thoracic Surgery, Korea University Guro Hospital, Korea University College of Medicine, Seoul (Korea, Republic of); Shin, Bong Kyung [Dept. of Pathology, Korea University Guro Hospital, Korea University College of Medicine, Seoul (Korea, Republic of)

    2011-10-15

    To evaluate the efficacy of CT fluoroscopy-guided core biopsy of small pulmonary nodules. This study included 62 patients (35 men, 27 women; age range, 36-85 years) that had a small ({<=} 20 mm) pulmonary nodule and underwent CT fluoroscopy-guided core biopsy. The overall diagnostic accuracy and complication rate were calculated. The diagnostic accuracy was compared between two groups according to the nodule size ({<=} 10 mm vs. > 10 mm), and nodule density (solid vs. subsolid). Malignant or premalignant lesions were finally diagnosed in 39 patients; 36 true-positive and three false-negative findings (sensitivity, 92%). A benign lesion was finally diagnosed in 23 patients, with no false-positive results (specificity, 100%). The overall diagnostic accuracy was 95%. The sensitivity and diagnostic accuracy were 85% and 91% for nodules {<=} 10 mm, and 96% and 97% for nodules > 10 mm (p > 0.05). The sensitivity and diagnostic accuracy were 93% and 96% in the solid group and 90% and 92% in the subsolid group (p > 0.05). Seventeen (27%) patients had a pneumothorax and two (3%) required a closed thoracostomy. CT fluoroscopy-guided core biopsy of small pulmonary nodules yields high diagnostic accuracy with acceptable complication rates.

  10. 1/f Noise and its coherence as a diagnostic tool for quality assessment of potentiometers

    NARCIS (Netherlands)

    Vandamme, E.P.; Vandamme, L.K.J.

    1994-01-01

    The excess noise of different types of potentiometers has been investigated, and all showed a 1/f noise power-spectral density. Two types of conductive tracks are considered: carbon black resin type and metal-oxide glass cermet type. Also considered are different types of sliders: 1) metal-point

  11. Improved Temperature Diagnostic for Non-Neutral Plasmas with Single-Electron Resolution

    Science.gov (United States)

    Shanman, Sabrina; Evans, Lenny; Fajans, Joel; Hunter, Eric; Nelson, Cheyenne; Sierra, Carlos; Wurtele, Jonathan

    2016-10-01

    Plasma temperature diagnostics in a Penning-Malmberg trap are essential for reliably obtaining cold, non-neutral plasmas. We have developed a setup for detecting the initial electrons that escape from a trapped pure electron plasma as the confining electrode potential is slowly reduced. The setup minimizes external noise by using a silicon photomultiplier to capture light emitted from an MCP-amplified phosphor screen. To take advantage of this enhanced resolution, we have developed a new plasma temperature diagnostic analysis procedure which takes discrete electron arrival times as input. We have run extensive simulations comparing this new discrete algorithm to our existing exponential fitting algorithm. These simulations are used to explore the behavior of these two temperature diagnostic procedures at low N and at high electronic noise. This work was supported by the DOE DE-FG02-06ER54904, and the NSF 1500538-PHY.

  12. Proceeding of JSPS-CAS core university program seminar on production and control of high performance plasmas with advanced plasma heating and diagnostic systems

    International Nuclear Information System (INIS)

    Gao Xiang; Morita, Shigeru

    2009-01-01

    The JSPS-CAS Core University Program (CUP) seminar on 'Production and control of high performance plasmas with advanced plasma heating and diagnostic systems' took place in Shiner hotel, Lijiang, China, 4-7 November 2008. This seminar was organized in the framework of CUP in the field of plasma and nuclear fusion. One special talk and 34 oral talks were presented in the seminar including 16 Japanese attendees. Production and control of high performance plasmas is a crucial issue for realizing an advanced nuclear fusion reactor in addition to developments of advanced plasma heating and diagnostics. This seminar was motivated along the issues. Results obtained from CUP activities during recent four years were summarized. Several crucial issues to be resolved near future were also extracted in this seminar. The 31 of the papers are indexed individually. (J.P.N.)

  13. Exploring cosmic origins with CORE: Inflation

    Science.gov (United States)

    Finelli, F.; Bucher, M.; Achúcarro, A.; Ballardini, M.; Bartolo, N.; Baumann, D.; Clesse, S.; Errard, J.; Handley, W.; Hindmarsh, M.; Kiiveri, K.; Kunz, M.; Lasenby, A.; Liguori, M.; Paoletti, D.; Ringeval, C.; Väliviita, J.; van Tent, B.; Vennin, V.; Ade, P.; Allison, R.; Arroja, F.; Ashdown, M.; Banday, A. J.; Banerji, R.; Bartlett, J. G.; Basak, S.; de Bernardis, P.; Bersanelli, M.; Bonaldi, A.; Borril, J.; Bouchet, F. R.; Boulanger, F.; Brinckmann, T.; Burigana, C.; Buzzelli, A.; Cai, Z.-Y.; Calvo, M.; Carvalho, C. S.; Castellano, G.; Challinor, A.; Chluba, J.; Colantoni, I.; Coppolecchia, A.; Crook, M.; D'Alessandro, G.; D'Amico, G.; Delabrouille, J.; Desjacques, V.; De Zotti, G.; Diego, J. M.; Di Valentino, E.; Feeney, S.; Fergusson, J. R.; Fernandez-Cobos, R.; Ferraro, S.; Forastieri, F.; Galli, S.; García-Bellido, J.; de Gasperis, G.; Génova-Santos, R. T.; Gerbino, M.; González-Nuevo, J.; Grandis, S.; Greenslade, J.; Hagstotz, S.; Hanany, S.; Hazra, D. K.; Hernández-Monteagudo, C.; Hervias-Caimapo, C.; Hills, M.; Hivon, E.; Hu, B.; Kisner, T.; Kitching, T.; Kovetz, E. D.; Kurki-Suonio, H.; Lamagna, L.; Lattanzi, M.; Lesgourgues, J.; Lewis, A.; Lindholm, V.; Lizarraga, J.; López-Caniego, M.; Luzzi, G.; Maffei, B.; Mandolesi, N.; Martínez-González, E.; Martins, C. J. A. P.; Masi, S.; McCarthy, D.; Matarrese, S.; Melchiorri, A.; Melin, J.-B.; Molinari, D.; Monfardini, A.; Natoli, P.; Negrello, M.; Notari, A.; Oppizzi, F.; Paiella, A.; Pajer, E.; Patanchon, G.; Patil, S. P.; Piat, M.; Pisano, G.; Polastri, L.; Polenta, G.; Pollo, A.; Poulin, V.; Quartin, M.; Ravenni, A.; Remazeilles, M.; Renzi, A.; Roest, D.; Roman, M.; Rubiño-Martin, J. A.; Salvati, L.; Starobinsky, A. A.; Tartari, A.; Tasinato, G.; Tomasi, M.; Torrado, J.; Trappe, N.; Trombetti, T.; Tucci, M.; Tucker, C.; Urrestilla, J.; van de Weygaert, R.; Vielva, P.; Vittorio, N.; Young, K.; Zannoni, M.

    2018-04-01

    We forecast the scientific capabilities to improve our understanding of cosmic inflation of CORE, a proposed CMB space satellite submitted in response to the ESA fifth call for a medium-size mission opportunity. The CORE satellite will map the CMB anisotropies in temperature and polarization in 19 frequency channels spanning the range 60–600 GHz. CORE will have an aggregate noise sensitivity of 1.7 μKṡ arcmin and an angular resolution of 5' at 200 GHz. We explore the impact of telescope size and noise sensitivity on the inflation science return by making forecasts for several instrumental configurations. This study assumes that the lower and higher frequency channels suffice to remove foreground contaminations and complements other related studies of component separation and systematic effects, which will be reported in other papers of the series "Exploring Cosmic Origins with CORE." We forecast the capability to determine key inflationary parameters, to lower the detection limit for the tensor-to-scalar ratio down to the 10‑3 level, to chart the landscape of single field slow-roll inflationary models, to constrain the epoch of reheating, thus connecting inflation to the standard radiation-matter dominated Big Bang era, to reconstruct the primordial power spectrum, to constrain the contribution from isocurvature perturbations to the 10‑3 level, to improve constraints on the cosmic string tension to a level below the presumptive GUT scale, and to improve the current measurements of primordial non-Gaussianities down to the fNLlocal inflation. Its capabilities will be further enhanced by combining with complementary future cosmological observations.

  14. Expression of Hepatitis C Virus Core and E2 antigenic recombinant proteins and their use for development of diagnostic assays.

    Science.gov (United States)

    Ali, Amjad; Nisar, Muhammad; Idrees, Muhammad; Rafique, Shazia; Iqbal, Muhammad

    2015-05-01

    Early diagnosis of HCV infection is based on detection of antibodies against HCV proteins using recombinant viral antigens. The present study was designed to select, clone and express the antigenic regions of Core and E2 genes from local HCV-3a genotype and to utilize the antigenic recombinant proteins (Core & E2) to develop highly sensitive, specific and economical diagnostic assays for detection of HCV infection. The antigenic sites were determined within Core and E2 genes and were then cloned in pET-28a expression vector. The right orientation of the desired inserted fragments of Core and E2 were confirmed via sequencing prior to expression and were then transformed in BL21 (DE3) pLysS strains of E. coli and induced with 0.5mM Isopropyl-b-D-thiogalactopyranoside (IPTG) for the production of antigenic recombinant proteins. The produced truncated antigens were then purified by Nickel affinity chromatography and were confirmed by western blotting, immunoblotting and enzyme-linked immunosorbent assay (ELISA). The expressed Core and E2 recombinant antigens were used to develop immunoblotting assay for the detection of anti-HCV antibodies in sera. With immunoblotting, a total of 93-HCV infected sera and 35-HCV negative individuals were tested for the presence of anti-HCV antibodies to the Core and E2 antigens. Recombinant antigen showed 100% reactivity against HCV infected sera, with no cross reactivity against HCV-negative sera. The immunoblot assay mixture of recombinant antigens (Core+E2) showed a strong reaction intensity in the test area (TA) as compared to the individual truncated Core and E2 recombinant antigens. In the in-house ELISA assay, mixed Core and E2 recombinant antigens showed 100% reactivity against a standardized panel of 150-HCV-positive sera and non reactivity against a standardized panel of 150 HCV-negative sera while also being non reactive to sera positive for other viral infections. The antigenic recombinant antigens also were tested for the

  15. Reactor noise in critical and accelerator driven sub-critical systems

    International Nuclear Information System (INIS)

    Degweker, S.B.; Rana, Y.S.

    2007-01-01

    Noise methods have long been used for reactor kinetics parameters measurement and as diagnostic tools for monitoring the health of a nuclear power plant. It is conceivable that noise techniques would find similar applications in ADS. Measurement/monitoring the degree of sub-criticality of an ADS is one such application for which noise based methods are being considered, among others such as the pulsed source method. For this reason, theoretical studies on ADS noise have appeared since the late nineties. The principal difference between critical reactor noise and ADS noise is due to the statistical properties of the source. Unlike the source due to radioactive decay present in ordinary reactors, the machine produced ADS source cannot be assumed to be a Poisson process. In addition the source is pulsed. All this requires a new theoretical approach to the subject. In a number of papers (beginning in 2000) such a theoretical approach has been developed in BARC. Over the years, our approach has received general acceptance. The paper gives a description of the subject of reactor noise and its applications in critical reactors. The theory of noise in ADS is then outlined, highlighting the differences in approach and results from that of critical reactors. (author)

  16. National NIF Diagnostic Program Interim Management Plan

    International Nuclear Information System (INIS)

    Warner, B

    2002-01-01

    The National Ignition Facility (NIF) has the mission of supporting Stockpile Stewardship and Basic Science research in high-energy-density plasmas. To execute those missions, the facility must provide diagnostic instrumentation capable of observing and resolving in time events and radiation emissions characteristic of the plasmas of interest. The diagnostic instrumentation must conform to high standards of operability and reliability within the NIF environment. These exacting standards, together with the facility mission of supporting a diverse user base, has led to the need for a central organization charged with delivering diagnostic capability to the NIF. The National NIF Diagnostics Program (NNDP) has been set up under the aegis of the NIF Director to provide that organization authority and accountability to the wide user community for NIF. The funds necessary to perform the work of developing diagnostics for NIF will be allocated from the National NIF Diagnostics Program to the participating laboratories and organizations. The participating laboratories and organizations will design, build, and commission the diagnostics for NIF. Restricted availability of funding has had an adverse impact, unforeseen at the time of the original decision to projectize NIF Core Diagnostics Systems and Cryogenic Target Handing Systems, on the planning and initiation of these efforts. The purpose of this document is to provide an interim project management plan describing the organizational structure and management processes currently in place for NIF Core Diagnostics Systems. Preparation of a Program Execution Plan for NIF Core Diagnostics Systems has been initiated and a current draft is provided as Attachment 1 to this document. The National NIF Diagnostics Program Interim Management Plan provides a summary of primary design criteria and functional requirements, current organizational structure, tracking and reporting procedures, and current planning estimates of project scope

  17. Vibration Finite Element Analysis of SC10 Dry-type Transformer Core

    Directory of Open Access Journals (Sweden)

    Gao Sheng Wei

    2014-06-01

    Full Text Available As the popularization and application of dry-type power transformer, its work when the vibration noise problem widely concerned, on the basis of time-varying electromagnetic field and structural mechanics equation, this paper established a finite element analysis model of dry-type transformer, through the electromagnetic field – Structural mechanics field – sound field more than physical field coupling calculation analysis, obtained in no load and the vibration modes of the core under different load and frequency. According to the transformer vibration mechanism, compared with the experimental data, verified the accuracy of the calculation results, as the core of how to provide the theory foundation and to reduce the noise of the experiment.

  18. Fractal characterization for noise signal validation in power reactors

    International Nuclear Information System (INIS)

    Aguilar Martinez, Omar

    2003-01-01

    Up to now, a great variety of methods is used for the dynamical characterization of different components of Nuclear Power Plants (NPPs). With this aim, time and spectral analysis are usually considered, and different tools of non-stationary and non-gaussian analysis are also presented. When applying non-lineal dynamics theory for noise signal validation purposes in power reactors, the extraction of fractal echoes plays a main role. Fractal characterization for noise signal validation purposes can be integrated to the task of processing and acquisition of time signals in noise (fluctuation parameters) analysis systems. The possibility of discrimination between deterministic chaotic signals and pure noise signals has been incorporated, as a complement; to noise signals analysis in normal and anomalous operational conditions in NPPs using a fractal approach. In this work the detailed analysis of a neutronic sensor response is considered and the fractal characterization of its dynamics state (i.e. sensor line) for noise signal classification, it is presented. The experiment from where the time series (signals) were obtained, was carried out at the Research Reactor of the Technical University of Budapest, Hungary, during a model experiment for ageing process study of in-core neutron detectors (author)

  19. Effects of noise-induced hearing loss within Port Harcourt metropolis ...

    African Journals Online (AJOL)

    This paper investigates the effects of Noise-Induced Hearing Loss within Port Harcourt Metropolis using a micro-controlled diagnostic audiometer (Kamplex KLD21).The data was obtained at two specific locations namely: Rivers State University of Science and Technology and Port Harcourt International Airport.

  20. Does image quality matter? Impact of resolution and noise on mammographic task performance

    International Nuclear Information System (INIS)

    Saunders, Robert S. Jr.; Baker, Jay A.; Delong, David M.; Johnson, Jeff P.; Samei, Ehsan

    2007-01-01

    The purpose of this study was to examine the effects of different resolution and noise levels on task performance in digital mammography. This study created an image set with images at three different resolution levels, corresponding to three digital display devices, and three different noise levels, with noise magnitudes similar to full clinical dose, half clinical dose, and quarter clinical dose. The images were read by five experienced breast imaging radiologists. The data were then analyzed to compute two accuracy statistics (overall classification accuracy and lesion detection accuracy) and performance at four diagnostic tasks (detection of microcalcifications, benign masses, malignant masses, and discrimination of benign and malignant masses). Human observer results showed decreasing display resolution had little effect on overall classification accuracy and individual diagnostic task performance, but increasing noise caused overall classification accuracy to decrease by a statistically significant 21% as the breast dose went to one quarter of its normal clinical value. The noise effects were most prominent for the tasks of microcalcification detection and mass discrimination. When the noise changed from full clinical dose to quarter clinical dose, the microcalcification detection performance fell from 89% to 67% and the mass discrimination performance decreased from 93% to 79%, while malignant mass detection performance remained relatively constant with values of 88% and 84%, respectively. As a secondary aim, the image set was also analyzed by two observer models to examine whether their performance was similar to humans. Observer models differed from human observers and each other in their sensitivity to resolution degradation and noise. The primary conclusions of this study suggest that quantum noise appears to be the dominant image quality factor in digital mammography, affecting radiologist performance much more profoundly than display resolution

  1. Calibration issues for neutron diagnostics

    International Nuclear Information System (INIS)

    Sadler, G.J.; Adams, J.M.; Barnes, C.W.

    1997-10-01

    In order for ITER to meet its operational and programmatic goals, it will be necessary to measure a wide range of plasma parameters. Some of the required parameters e.g., neutron yield, fusion power and power density, ion temperature profile in the core plasma, and characteristics of confined and escaping alpha particle populations are best measured by fusion product diagnostic techniques. To make these measurements, ITER will have dedicated diagnostic systems, including radial and vertical neutron cameras, neutron and gamma ray spectrometers, internal and external fission chambers, a neutron activation system, and diagnostics for confined and escaping alpha particles. Engineering integration of many of these systems is in progress, and other systems are under investigation. This paper summarizes the present state of design of fusion product diagnostic systems for ITER and discusses expected measurement capability

  2. Noise suppression by noise

    OpenAIRE

    Vilar, J. M. G. (José M. G.), 1972-; Rubí Capaceti, José Miguel

    2001-01-01

    We have analyzed the interplay between an externally added noise and the intrinsic noise of systems that relax fast towards a stationary state, and found that increasing the intensity of the external noise can reduce the total noise of the system. We have established a general criterion for the appearance of this phenomenon and discussed two examples in detail.

  3. Beam diagnostics and control for SLC

    International Nuclear Information System (INIS)

    Ross, M.C.

    1987-01-01

    Construction of the SLAC Linear Collider has posed some new problems in beam diagnostic device design. Typical beam sizes are small when compared with conventional storage rings, orbit tolerances are tighter and the pulsed nature of the machine means that signal to noise enhancement by averaging is not always possible. Thus the diagnostics must have high resolution, high absolute accuracy and must deliver data from a single puls. In practice the required performance level depends on the function and dynamics of a given region in the collider. In this paper, the authors review the major beam diagnostic system and then discuss the global data acquisition schemes. Because space is limited each system is described only in a very cursory fashion. More details may be found in the cited papers

  4. Core Muscle Injury/Sports Hernia/Athletic Pubalgia, and Femoroacetabular Impingement.

    Science.gov (United States)

    Ross, James R; Stone, Rebecca M; Larson, Christopher M

    2015-12-01

    Core muscle injury/sports hernia/athletic pubalgia is an increasingly recognized source of pain, disability, and time lost from athletics. Groin pain among athletes, however, may be secondary to various etiologies. A thorough history and comprehensive physical examination, coupled with appropriate diagnostic imaging, may improve the diagnostic accuracy for patients who present with core muscular injuries. Outcomes of nonoperative management have not been well delineated, and multiple operative procedures have been discussed with varying return-to-athletic activity rates. In this review, we outline the clinical entity and treatment of core muscle injury and athletic pubalgia. In addition, we describe the relationship between athletic pubalgia and femoroacetabular impingement along with recent studies that have investigated the treatment of these related disorders.

  5. Linear phase formation by noise simulator

    International Nuclear Information System (INIS)

    Hazi, G.; Por, G.

    1998-01-01

    A new simulation technique is introduced to study noise propagation in nuclear power plants. Noise processes are considered as time functions, and the dynamic behaviour of the reactor core is modelled by ordinary and partial differential equations. The equations are solved by numerical methods and the results (time series) are considered as virtual measurements. The auto power spectral density and the cross power spectral density of these time series are calculated by traditional techniques. The spectrum obtained is compared with the analytical solution to validate the new simulation approach. After validation, the simulator is expanded to investigate some physical phenomena which are unmanageable by analytical calculations. Propagating disturbances are studied, and the effect of non-flat flux shape on phase curves is demonstrated. Numerical problems also are briefly discussed. (author)

  6. Microprocessor-based integrated LMFBR core surveillance

    International Nuclear Information System (INIS)

    Gmeiner, L.

    1984-06-01

    This report results from a joint study of KfK and INTERATOM. The aim of this study is to explore the advantages of microprocessors and microelectronics for a more sophisticated core surveillance, which is based on the integration of separate surveillance techniques. Due to new developments in microelectronics and related software an approach to LMFBR core surveillance can be conceived that combines a number of measurements into a more intelligent decision-making data processing system. The following techniques are considered to contribute essentially to an integrated core surveillance system: - subassembly state and thermal hydraulics performance monitoring, - temperature noise analysis, - acoustic core surveillance, - failure characterization and failure prediction based on DND- and cover gas signals, and - flux tilting techniques. Starting from a description of these techniques it is shown that by combination and correlation of these individual techniques a higher degree of cost-effectiveness, reliability and accuracy can be achieved. (orig./GL) [de

  7. Identification of reactor failure states using noise methods, and spatial power distribution

    International Nuclear Information System (INIS)

    Vavrin, J.; Blazek, J.

    1981-01-01

    A survey is given of the results achieved. Methodical means and programs were developed for the control computer which may be used in noise diagnostics and in the control of reactor power distribution. Statistical methods of processing the noise components of the signals of measured variables were used for identifying failures of reactors. The method of the synthesis of the neutron flux was used for modelling and evaluating the reactor power distribution. For monitoring and controlling the power distribution a mathematical model of the reactor was constructed suitable for control computers. The uses of noise analysis methods are recommended and directions of further development shown. (J.P.)

  8. An Anomalous Noise Events Detector for Dynamic Road Traffic Noise Mapping in Real-Life Urban and Suburban Environments

    Directory of Open Access Journals (Sweden)

    Joan Claudi Socoró

    2017-10-01

    Full Text Available One of the main aspects affecting the quality of life of people living in urban and suburban areas is their continued exposure to high Road Traffic Noise (RTN levels. Until now, noise measurements in cities have been performed by professionals, recording data in certain locations to build a noise map afterwards. However, the deployment of Wireless Acoustic Sensor Networks (WASN has enabled automatic noise mapping in smart cities. In order to obtain a reliable picture of the RTN levels affecting citizens, Anomalous Noise Events (ANE unrelated to road traffic should be removed from the noise map computation. To this aim, this paper introduces an Anomalous Noise Event Detector (ANED designed to differentiate between RTN and ANE in real time within a predefined interval running on the distributed low-cost acoustic sensors of a WASN. The proposed ANED follows a two-class audio event detection and classification approach, instead of multi-class or one-class classification schemes, taking advantage of the collection of representative acoustic data in real-life environments. The experiments conducted within the DYNAMAP project, implemented on ARM-based acoustic sensors, show the feasibility of the proposal both in terms of computational cost and classification performance using standard Mel cepstral coefficients and Gaussian Mixture Models (GMM. The two-class GMM core classifier relatively improves the baseline universal GMM one-class classifier F1 measure by 18.7% and 31.8% for suburban and urban environments, respectively, within the 1-s integration interval. Nevertheless, according to the results, the classification performance of the current ANED implementation still has room for improvement.

  9. Empirical mode decomposition of the ECG signal for noise removal

    Science.gov (United States)

    Khan, Jesmin; Bhuiyan, Sharif; Murphy, Gregory; Alam, Mohammad

    2011-04-01

    Electrocardiography is a diagnostic procedure for the detection and diagnosis of heart abnormalities. The electrocardiogram (ECG) signal contains important information that is utilized by physicians for the diagnosis and analysis of heart diseases. So good quality ECG signal plays a vital role for the interpretation and identification of pathological, anatomical and physiological aspects of the whole cardiac muscle. However, the ECG signals are corrupted by noise which severely limit the utility of the recorded ECG signal for medical evaluation. The most common noise presents in the ECG signal is the high frequency noise caused by the forces acting on the electrodes. In this paper, we propose a new ECG denoising method based on the empirical mode decomposition (EMD). The proposed method is able to enhance the ECG signal upon removing the noise with minimum signal distortion. Simulation is done on the MIT-BIH database to verify the efficacy of the proposed algorithm. Experiments show that the presented method offers very good results to remove noise from the ECG signal.

  10. Kenaf Core Particleboard and Its Sound Absorbing Properties

    OpenAIRE

    Mohamad Jani Saad; Izran Kamal

    2012-01-01

    In this study, kenaf (Hibiscus cannabinus) core particleboards as insulation boards were manufactured. The boards were fabricated with three different densities i.e. 350 kg/m3, 450 kg/m3 and 550 kg/m3 at urea formaldehyde resin (UF) loadings of 8%, 10% and 12% (w/w) based on the dry weight of the kenaf core particles. The fabricated boards were evaluated for its noise acoustical coefficients (NAC) by following the ASTM E1050-98 standard requirements. The study revealed that boards with higher...

  11. A study of power fluctuations in a flip fuel reactor using the technique of noise analysis

    Energy Technology Data Exchange (ETDEWEB)

    Randall, J D; Wood, G C; Edwards, M A [Texas A and M University (United States)

    1974-07-01

    The Nuclear Science Center Reactor at Texas A and M University has experienced minor power fluctuations when operating at or near 1 megawatt. A noise analysis system was developed to investigate these fluctuations assuming that void formation, primarily due to nucleate boiling, was the cause. Experiments were carried out to correlate boiling noise with power level, fission product poisoning, and pool temperature. Results show that void formation in the core is the probable cause of the fluctuations with the onset of boiling occurring at 400 Kw. Data was also obtained that indicated the presence of boiling in a standard TRIGA core. (author)

  12. Recent progress in safety-related applications of reactor noise analysis

    International Nuclear Information System (INIS)

    Hirota, Jitsuya; Shinohara, Yoshikuni; Saito, Keiichi

    1982-01-01

    Recent progress in safety-related applications of reactor noise analysis is reviewed, mainly referring to various papers presented at the Third Specialists' Meeting on Reactor Noise (SMORN-III) held in Tokyo in 1981. Advances in application of autoregressive model, coherence analysis and pattern recognition technique are significant since SMORN-II in 1977. Development of reactor diagnosis systems based on noise analysis is in progress. Practical experiences in the safety-related applications to power plants are being accumulated. Advances in quantitative monitoring of vibration of internal structures in PWR and diagnosis of core stability and control system characteristics in BWR are notable. Acoustic methods are also improved to detect sodium boiling in LMFBR. The Reactor Noise Analysis Benchmark Test performed by Japan in connection with SMORN-III is successful so that it is possible to proceed to the second stage of the benchmark test. (author)

  13. Fast reactor core monitoring by analysis of temperature noise

    International Nuclear Information System (INIS)

    Dubuisson, B.; Smolarz, A.

    1984-01-01

    The study shows, with the results obtained, how it is possible to approach the problem of diagnosis with a technique based on the use of algorithms for statistical pattern recognition was justifiable. The results presented here, with a view to their use for fast breeder reactor core surveillance, are very encouraging, the most important point being the data representation. For this study, it was difficult to find the most suitable parameters for characterizing the various simulated core states, however, despite this handicap, the classification algorithm provided quite acceptable results. The second point concerns the characterization of a system's evolution. The criterion defined was chosen for adaptation to our algorithm. One acertained that it was possible to characterize evolution on the basis of this criterion as long as the rejected points were not too far from the known learning sets. Under these circumstances, the advantage in characterizing evolution in that the changes in evolution occur when the rejected points have a tendency to agglomerate in a small area of space could be seen. This phenomenon thus makes it possible to forsee whether the creation of a new class is possible. Where the rejected points are far away from the known learning sets, the criterion used proved to be too sensitive and the characterization of evolution was less satisfactory

  14. Investigation of space-energy effects in the reactivity measurement by neutron noise with excore detectors in a reflected LWR

    International Nuclear Information System (INIS)

    Lescano, V.H.; Behringer, K.

    1982-01-01

    Practical application of the zero-crossing correlation method for measuring slightly-subcritical reactivities in a swimming-pool reactor required the use of detector locations in the reflector zone near to the core boundary. Experimental investigations of neutron-noise cross-power spectra showed significant deviations from the point-reactor model at higher frequencies (> 100 Hz). Nevertheless, the use of the point-reactor model was found to be a useful approach in the analysis of the zero-crossing correlation method, yielding results which agreed well with those obtained from the rod-drop method. The theoretical part of the work is concerned with a space-dependent model calculation in two-group diffusion theory to support the experimental findings. The model calculation can explain the trends observed in the neutron-noise spectra as well as the applicability of the point-reactor model to the zero-crossing correlation method. To obtain better insight, the calculations have been extended to neutron-noise spectra when one or both detectors are located in the core zone. In the case of a large core and widely-spaced detectors, with at least one detector in the core zone, a sink frequency appears in the spectra. This effect is well known in coupled-core kinetics. (author)

  15. Investigation of power oscillation mechanisms based on noise analysis at Forsmark-1 BWR

    International Nuclear Information System (INIS)

    Oguma, Ritsuo

    1996-01-01

    Noise analysis has been performed for stability test data collected during reactor start-up in January 1989 at the boiling water reactor (BWR) Forsmark unit 1. A unique instrumentation to measure local coolant flow in this reactor allowed investigation of dynamic interactions between neutron flux and coolant flow noise signals at different radial positions in the core. The causal relationship for these signals was evaluated based on a method called signal transmission path (STP) analysis with the aim of identifying the principal mechanism of power oscillations in this reactor. The results of the present study indicated that large amplitude power oscillations were induced by two instability mechanisms concurrent in the core. The first is the global void reactivity feedback effect which played the most significant role to power oscillations at a resonant frequency of about 0.53 Hz. The second is the thermal-hydraulics coupling with neutron kinetics, inducing resonant oscillations at about 0.45 Hz. The latter was found to be active only in a certain core region. A peculiar phenomenon of amplitude modulations observed in some local power range monitor (LPRM) signals was also examined. It was interpreted to occur as the consequence of these two resonant power oscillations, the frequencies of which lie close to each other. The noise analysis technique applied in the present study is expected to be useful to get a deeper understanding of the power oscillation mechanism which is active in the reactor under evaluation. The technique may be applicable to BWRs with instruments to measure local channel flow together with in-core neutron detectors. (Author)

  16. Current status of core needle biopsy of the thyroid

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Jung Hwan [Dept. of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2017-04-15

    Thyroid nodules are a common clinical problem. Fine-needle aspiration (FNA) and large-needle biopsy have been used to diagnose thyroid nodules. Before the 1980s, large-needle biopsy was the standard procedure for the thyroid, but FNA became the standard diagnostic tool in the 1980s because it is a safe procedure that leads to accurate diagnoses. With advances in core needle biopsy (CNB) devices (i.e., spring-activated core needles) and development of high-resolution ultrasound, it has become possible to make accurate diagnoses while minimizing complications. Although 18- to 21-gauge core needles can be used to biopsy thyroid nodules, 18-gauge needles are most commonly used in Korea. The relationships among the size of the needle, the number of core specimens, and diagnostic accuracy have not yet been conclusively established, but the general tendency is that thinner needles cause less damage to the normal thyroid, but allow a smaller amount of thyroid tissue to be biopsied to be obtained. These relationships may be validated in the future.

  17. A 0.18 μm CMOS inductorless complementary-noise-canceling-LNA for TV tuner applications

    International Nuclear Information System (INIS)

    Yuan Haiquan; Lin Fujiang; Fu Zhongqian; Huang Lu

    2010-01-01

    This paper presents an inductorless complementary-noise-canceling LNA (CNCLNA) for TV tuners. The CNCLNA exploits single-to-differential topology, which consists of a common gate stage and a common source stage. The complementary topology can save power and improve the noise figure. Linearity is also enhanced by employing a multiple gated transistors technique. The chip is implemented in SMIC 0.18 μm CMOS technology. Measurement shows that the proposed CNCLNA achieves 13.5-16 dB voltage gain from 50 to 860 MHz, the noise figure is below 4.5 dB and has a minimum value of 2.9 dB, and the best P 1dB is -7.5 dBm at 860 MHz. The core consumes 6 mA current with a supply voltage of 1.8 V, while the core area is only 0.2 x 0.2 mm 2 . (semiconductor integrated circuits)

  18. Proceeding of JSPS-CAS Core University Program seminar on production and control of high performance plasmas with advanced plasma heating and diagnostic systems

    International Nuclear Information System (INIS)

    Gao Xiang; Morita, Shigeru

    2011-02-01

    The JSPS-CAS Core University Program (CUP) seminar on 'Production and control of high performance plasmas with advanced plasma heating and diagnostic systems' took place in Guilin Bravo Hotel, Guilin, China, 1-4 November 2010. This seminar was organized in the framework of CUP in the field of plasma and nuclear fusion. Two special talks and 46 oral talks were presented in the seminar including 36 Chinese, 18 Japanese and 4 Korean attendees. Production and control of high performance plasmas is a crucial issue for realizing an advanced nuclear fusion reactor in addition to developments of advanced plasma heating and diagnostics. This seminar was motivated along the issues. Results in the field of fusion experiments obtained through CUP activities during recent two years were summarized. Possible direction of future collaboration and further encouragement of scientific activity of younger scientists were also discussed in this seminar with future experimental plans in both countries. (author)

  19. Information contraction and extraction by multivariate autoregressive (MAR) modelling. Pt. 2. Dominant noise sources in BWRS

    International Nuclear Information System (INIS)

    Morishima, N.

    1996-01-01

    The multivariate autoregressive (MAR) modeling of a vector noise process is discussed in terms of the estimation of dominant noise sources in BWRs. The discussion is based on a physical approach: a transfer function model on BWR core dynamics is utilized in developing a noise model; a set of input-output relations between three system variables and twelve different noise sources is obtained. By the least-square fitting of a theoretical PSD on neutron noise to an experimental one, four kinds of dominant noise sources are selected. It is shown that some of dominant noise sources consist of two or more different noise sources and have the spectral properties of being coloured and correlated with each other. By diagonalizing the PSD matrix for dominant noise sources, we may obtain an MAR expression for a vector noise process as a response to the diagonal elements(i.e. residual noises) being white and mutually-independent. (Author)

  20. Power reactor noise studies and applications

    Energy Technology Data Exchange (ETDEWEB)

    Arzhanov, V

    2002-03-01

    The present thesis deals with the neutron noise arising in power reactor systems. Generally, it can be divided into two major parts: first, neutron noise diagnostics, or more specifically, novel methods and algorithms to monitor nuclear industrial reactors; and second, contributions to neutron noise theory as applied to power reactor systems. Neutron noise diagnostics is presented by two topics. The first one is a theoretical study on the possibility to use a newly proposed current-flux (C/F) detector in Pressurised Water Reactors (PWR) for the localisation of anomalies. The second topic concerns various methods to detect guide tube impacting in Boiling Water Reactors (BWR). The significance of these problems comes from the operational experience. The thesis describes a novel method to localise vibrating control rods in a PWR by using only one C/F detector. Another novel method, based on wavelet analysis, is put forward to detect impacting guide tubes in a BWR. Neutron noise theory is developed for both Accelerator Driven Systems (ADS) and traditional reactors. By design the accelerator-driven systems would operate in a subcritical mode with a strong external source. This calls for a revision of many concepts and methods that have been developed for traditional reactors and also it poses a number of new problems. As for the latter, the thesis investigates the space-dependent neutron noise caused by a fluctuating source. It is shown that the frequency-dependent spatial behaviour exhibits some new properties that are different from those known in traditional critical systems. On the other hand, various reactor physics approximations (point kinetic, adiabatic etc.) have not been defined yet for the subcritical systems. In this respect the thesis presents a systematic formulation of the above mentioned approximations as well as investigations of their properties. Another important problem in neutron noise theory is the treatment of moving boundaries. In this case one

  1. Power reactor noise studies and applications

    International Nuclear Information System (INIS)

    Arzhanov, V.

    2002-03-01

    The present thesis deals with the neutron noise arising in power reactor systems. Generally, it can be divided into two major parts: first, neutron noise diagnostics, or more specifically, novel methods and algorithms to monitor nuclear industrial reactors; and second, contributions to neutron noise theory as applied to power reactor systems. Neutron noise diagnostics is presented by two topics. The first one is a theoretical study on the possibility to use a newly proposed current-flux (C/F) detector in Pressurised Water Reactors (PWR) for the localisation of anomalies. The second topic concerns various methods to detect guide tube impacting in Boiling Water Reactors (BWR). The significance of these problems comes from the operational experience. The thesis describes a novel method to localise vibrating control rods in a PWR by using only one C/F detector. Another novel method, based on wavelet analysis, is put forward to detect impacting guide tubes in a BWR. Neutron noise theory is developed for both Accelerator Driven Systems (ADS) and traditional reactors. By design the accelerator-driven systems would operate in a subcritical mode with a strong external source. This calls for a revision of many concepts and methods that have been developed for traditional reactors and also it poses a number of new problems. As for the latter, the thesis investigates the space-dependent neutron noise caused by a fluctuating source. It is shown that the frequency-dependent spatial behaviour exhibits some new properties that are different from those known in traditional critical systems. On the other hand, various reactor physics approximations (point kinetic, adiabatic etc.) have not been defined yet for the subcritical systems. In this respect the thesis presents a systematic formulation of the above mentioned approximations as well as investigations of their properties. Another important problem in neutron noise theory is the treatment of moving boundaries. In this case one

  2. Expert system for fast reactor diagnostic

    International Nuclear Information System (INIS)

    Parcy, J.P.

    1982-09-01

    A general description of expert systems is given. The operation of a fast reactor is reviewed. The expert system to the diagnosis of breakdowns limited to the reactor core. The structure of the system is described: specification of the diagnostics; structure of the data bank and evaluation of the rules; specification of the prediagnostics and evaluation; explanation of the diagnostics; time evolution of the system; comparison with other expert systems. Applications to some cases of faults are finally presented [fr

  3. A Design of Experiments Investigation of Offset Streams for Supersonic Jet Noise Reduction

    Science.gov (United States)

    Henderson, Brenda; Papamoschou, Dimitri

    2014-01-01

    An experimental investigation into the noise characteristics of a dual-stream jet with four airfoils inserted in the fan nozzle was conducted. The intent of the airfoils was to deflect the fan stream relative to the core stream and, therefore, impact the development of the secondary potential core and noise radiated in the peak jet-noise direction. The experiments used a full-factorial Design of Experiments (DoE) approach to identify parameters and parameter interactions impacting noise radiation at two azimuthal microphone array locations, one of which represented a sideline viewing angle. The parameters studied included airfoil angle-of-attack, airfoil azimuthal location within the fan nozzle, and airfoil axial location relative to the fan-nozzle trailing edge. Jet conditions included subsonic and supersonic fan-stream Mach numbers. Heated jets conditions were simulated with a mixture of helium and air to replicate the exhaust velocity and density of the hot jets. The introduction of the airfoils was shown to impact noise radiated at polar angles in peak-jet noise direction and to have no impact on noise radiated at small and broadside polar angles and to have no impact on broadband-shock-associated noise. The DoE analysis showed the main effects impacting noise radiation at sideline-azimuthal-viewing angles included airfoil azimuthal angle for the airfoils on the lower side of the jet near the sideline array and airfoil trailing edge distance (with airfoils located at the nozzle trailing edge produced the lowest sound pressure levels). For an array located directly beneath the jet (and on the side of the jet from which the fan stream was deflected), the main effects impacting noise radiation included airfoil angle-of-attack and airfoil azimuthal angle for the airfoils located on the observation side of the jet as well and trailing edge distance. Interaction terms between multiple configuration parameters were shown to have significant impact on the radiated

  4. Implementation of the neutron noise technique under the UBERA-6 project

    International Nuclear Information System (INIS)

    Gomez, Angel; Bellino, Pablo A.

    2009-01-01

    Using the neutron noise technique, kinetics parameters estimations and power calibration were performed in the new core of the RA-6 reactor. These activities were carried on under the nuclear start-up of the UBERA-6 project, which consist in the change of core and power increase of the reactor. In a first stage, in joint with the power estimation, the decay constant of the prompt neutrons (α c ) was estimated. Its value was found to agree with the calculations obtained from neutron codes. Lately, in the high power stage, estimators of the calibration factors for the 16 N detection device were obtained. A thorough analysis of the linearity of the instrumentation used was done, and an alternative methodology was applied in order to estimate the aforementioned factor. The calibration factor obtained by the neutron noise technique was in agreement with the one obtained by thermal balance. (author)

  5. Effects of background noise on total noise annoyance

    Science.gov (United States)

    Willshire, K. F.

    1987-01-01

    Two experiments were conducted to assess the effects of combined community noise sources on annoyance. The first experiment baseline relationships between annoyance and noise level for three community noise sources (jet aircraft flyovers, traffic and air conditioners) presented individually. Forty eight subjects evaluated the annoyance of each noise source presented at four different noise levels. Results indicated the slope of the linear relationship between annoyance and noise level for the traffic noise was significantly different from that of aircraft and of air conditioner noise, which had equal slopes. The second experiment investigated annoyance response to combined noise sources, with aircraft noise defined as the major noise source and traffic and air conditioner noise as background noise sources. Effects on annoyance of noise level differences between aircraft and background noise for three total noise levels and for both background noise sources were determined. A total of 216 subjects were required to make either total or source specific annoyance judgements, or a combination of the two, for a wide range of combined noise conditions.

  6. Reduction of vibrational interference from the iron core on HBTXIA

    International Nuclear Information System (INIS)

    Wilcock, P.D.

    1981-01-01

    The HBTXIA machine is a toroidal reversed field pinch which utilises a 1 volt second iron core. This paper looks briefly at the sources of vibration from the iron core and describes the design of a novel support system that has been installed to minimise the transmission of vibration to plasma diagnostics and other equipment during the machine pulse. Vibration measurements on the completed installation when the core is driven to saturation are reported and compared with calculations for a ground mounted core. (author)

  7. Maximizing noise energy for noise-masking studies.

    Science.gov (United States)

    Jules Étienne, Cédric; Arleo, Angelo; Allard, Rémy

    2017-08-01

    Noise-masking experiments are widely used to investigate visual functions. To be useful, noise generally needs to be strong enough to noticeably impair performance, but under some conditions, noise does not impair performance even when its contrast approaches the maximal displayable limit of 100 %. To extend the usefulness of noise-masking paradigms over a wider range of conditions, the present study developed a noise with great masking strength. There are two typical ways of increasing masking strength without exceeding the limited contrast range: use binary noise instead of Gaussian noise or filter out frequencies that are not relevant to the task (i.e., which can be removed without affecting performance). The present study combined these two approaches to further increase masking strength. We show that binarizing the noise after the filtering process substantially increases the energy at frequencies within the pass-band of the filter given equated total contrast ranges. A validation experiment showed that similar performances were obtained using binarized-filtered noise and filtered noise (given equated noise energy at the frequencies within the pass-band) suggesting that the binarization operation, which substantially reduced the contrast range, had no significant impact on performance. We conclude that binarized-filtered noise (and more generally, truncated-filtered noise) can substantially increase the energy of the noise at frequencies within the pass-band. Thus, given a limited contrast range, binarized-filtered noise can display higher energy levels than Gaussian noise and thereby widen the range of conditions over which noise-masking paradigms can be useful.

  8. Active Noise Control for Dishwasher noise

    Science.gov (United States)

    Lee, Nokhaeng; Park, Youngjin

    2016-09-01

    The dishwasher is a useful home appliance and continually used for automatically washing dishes. It's commonly placed in the kitchen with built-in style for practicality and better use of space. In this environment, people are easily exposed to dishwasher noise, so it is an important issue for the consumers, especially for the people living in open and narrow space. Recently, the sound power levels of the noise are about 40 - 50 dBA. It could be achieved by removal of noise sources and passive means of insulating acoustical path. For more reduction, such a quiet mode with the lower speed of cycle has been introduced, but this deteriorates the washing capacity. Under this background, we propose active noise control for dishwasher noise. It is observed that the noise is propagating mainly from the lower part of the front side. Control speakers are placed in the part for the collocation. Observation part of estimating sound field distribution and control part of generating the anti-noise are designed for active noise control. Simulation result shows proposed active noise control scheme could have a potential application for dishwasher noise reduction.

  9. Identification of neutron noise sources in a boiling water reactor

    International Nuclear Information System (INIS)

    Sides, W.H. Jr.; Mathis, M.V.; Smith, C.M.

    1977-01-01

    Measurements were made at units 2 and 3 of the Browns Ferry Nuclear Power Plant in order to characterize the noise signatures of the neutron and process signals and to determine the usefulness of such signatures for anomaly detection in BWR-4s. Previous measurements and theoretical analyses of BWR noise by others were concerned with the determination of steam velocity and void fraction (using the local component of neutron noise) and with the sources of global noise. The work described is under a five-part program to develop a complete and systematic analysis and representation of BWR neutron and process noise through complementary measurements and stochastic model developments. The parts are: (1) recording as many neutron detector and process noise signals as are available in a BWR-4; (2) reducing these data to noise signatures in order to perform an empirical analysis of these signatures, and documenting the relationships between the signals from spatially separated neutron detectors and between neutron and process variables; (3) developing spatially dependent neutronic models coupled with thermal-hydraulic models to aid in interpreting the observed relationships among the measured noise signatures, (4) comparing measured noise signatures with model predictions to obtain additional insight into BWR-4 dynamic behavior and to validate the models; and (5) using these models to predict the sensitivity of noise monitoring for detection, surveillance, and diagnosis of postulated in-core anomalies in BWRs. The paper describes the procedures used to obtain the noise recordings and presents initial empirical analysis and observations pertaining to the noise signatures and the relationships between several noise variables in the 0.01- to 1-Hz range. The mathematical models have not been developed sufficiently to report theoretical results or to compare measured spectra with model predictions at this time

  10. Open Rotor - Analysis of Diagnostic Data

    Science.gov (United States)

    Envia, Edmane

    2011-01-01

    NASA is researching open rotor propulsion as part of its technology research and development plan for addressing the subsonic transport aircraft noise, emission and fuel burn goals. The low-speed wind tunnel test for investigating the aerodynamic and acoustic performance of a benchmark blade set at the approach and takeoff conditions has recently concluded. A high-speed wind tunnel diagnostic test campaign has begun to investigate the performance of this benchmark open rotor blade set at the cruise condition. Databases from both speed regimes will comprise a comprehensive collection of benchmark open rotor data for use in assessing/validating aerodynamic and noise prediction tools (component & system level) as well as providing insights into the physics of open rotors to help guide the development of quieter open rotors.

  11. Comparison of Histologic Core Portions Acquired from a Core Biopsy Needle and a Conventional Needle in Solid Mass Lesions: A Prospective Randomized Trial.

    Science.gov (United States)

    Lee, Ban Seok; Cho, Chang-Min; Jung, Min Kyu; Jang, Jung Sik; Bae, Han Ik

    2017-07-15

    The superiority of endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) over EUS-guided fine needle aspiration (EUS-FNA) remains controversial. Given the lack of studies analyzing histologic specimens acquired from EUS-FNB or EUS-FNA, we compared the proportion of the histologic core obtained from both techniques. A total of 58 consecutive patients with solid mass lesions were enrolled and randomly assigned to the EUS-FNA or EUS-FNB groups. The opposite needle was used after the failure of core tissue acquisition using the initial needle with up to three passes. Using computerized analyses of the scanned histologic slide, the overall area and the area of the histologic core portion in specimens obtained by the two techniques were compared. No significant differences were identified between the two groups with respect to demographic and clinical characteristics. Fewer needle passes were required to obtain core specimens in the FNB group (pcore (11.8%±19.5% vs 8.0%±11.1%, p=0.376) or in the diagnostic accuracy (80.6% vs 81.5%, p=0.935) between two groups. The proportion of histologic core and the diagnostic accuracy were comparable between the FNB and FNA groups. However, fewer needle passes were required to establish an accurate diagnosis in EUS-FNB.

  12. Metastatic renal cell carcinoma in the thyroid gland: ultrasonographic features and the diagnostic role of core needle biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Song, Ok Kyu; Koo, Ja Seung; Kwak, Jin Young; Moon, Hee Jung; Yoon, Jung Hyun; Kim, Eun Kyung [Severance Hospital, Yonsei University College of Medicine, Seoul(Korea, Republic of)

    2017-07-15

    The aims of this study were to present the ultrasonographic (US) features of metastatic renal cell carcinoma (RCC) in the thyroid gland and to evaluate the diagnostic utility of fine needle aspiration (FNA) and core needle biopsy (CNB). Eight patients with nine metastatic RCC nodules in the thyroid glands who were treated from January 2002 to March 2015 in a single tertiary hospital were consecutively selected and retrospectively reviewed. US features and clinical history were obtained from the institution’s medical database. FNA was performed nine times on eight nodules and CNB was performed six times on six nodules. The diagnostic utility of FNA and CNB was evaluated. All nine nodules showed mass formation without diffuse thyroid involvement. On ultrasonography, metastatic RCC nodules were solid (100%), hypoechoic (100%), and ovalshaped nodules with a well-defined smooth margin (88.9%) and increased vascularity (100%, with 55% showing extensive vascularity). No calcifications were noted in any nodules. Lymph node metastasis and direct extension to nearby structures beyond the thyroid gland were not found. One FNA (11%) was able to confirm metastatic RCC, whereas all six CNBs confirmed metastatic RCC. Metastatic RCC appears as oval-shaped hypoechoic solid nodules with well-defined smooth margins, no calcifications, and increased vascularity on ultrasonography. Characteristic US features along with a previous history of RCC should raise clinical suspicion, and CNB should be performed to make an accurate diagnosis.

  13. Plastic scintillation dosimetry for radiation therapy: minimizing capture of Cerenkov radiation noise

    International Nuclear Information System (INIS)

    Beddar, A Sam; Suchowerska, Natalka; Law, Susan H

    2004-01-01

    Over the last decade, there has been an increased interest in scintillation dosimetry using small water-equivalent plastic scintillators, because of their favourable characteristics when compared with other more commonly used detector systems. Although plastic scintillators have been shown to have many desirable dosimetric properties, as yet there is no successful commercial detector system of this type available for routine clinical use in radiation oncology. The main factor preventing this new technology from realizing its full potential in commercial applications is the maximization of signal coupling efficiency and the minimization of noise capture. A principal constituent of noise is Cerenkov radiation. This study reports the calculated capture of Cerenkov radiation by an optical fibre in the special case where the radiation is generated by a relativistic particle on the fibre axis and the fibre axis is parallel to the Cerenkov cone. The fraction of radiation captured is calculated as a function of the fibre core refractive index and the refractive index difference between the core and the cladding of the fibre for relativistic particles. This is then used to deduce the relative intensity captured for a range of fibre core refractive indices and fibre core-cladding refractive index differences. It is shown that the core refractive index has little effect on the amount of radiation captured compared to the refractive index difference. The implications of this result for the design of radiation therapy plastic scintillation dosimeters are considered

  14. Effectiveness of core biopsy for screen-detected breast lesions under 10 mm: implications for surgical management.

    Science.gov (United States)

    Farshid, Gelareh; Downey, Peter; Pieterse, Steve; Gill, P Grantley

    2017-09-01

    Technical advances have improved the detection of small mammographic lesions. In the context of mammographic screening, accurate sampling of these lesions by percutaneous biopsy is crucial in limiting diagnostic surgical biopsies, many of which show benign results. Women undergoing core biopsy between January 1997 and December 2007 for core histology, 345 women (43.0%) were immediately cleared of malignancy and 300 (37.4%) were referred for definitive cancer treatment. A further 157 women (19.6%) required diagnostic surgical biopsy because of indefinite or inadequate core results or radiological-pathological discordance, and one woman (0.1%) needed further imaging in 12 months. The open biopsies were malignant in 46 (29.3%) cases. The positive predictive value of malignant core biopsy was 100%. The negative predictive value for benign core results was 97.7%, and the false-negative rate was 2.6%. The lesion could not be visualized after core biopsy in 5.1% of women and in 4.0% of women with malignant core biopsies excision specimens did not contain residual malignancy. Excessive delays in surgery because of complications of core biopsy were not reported. Even at this small size range, core biopsy evaluation of screen-detected breast lesions is highly effective and accurate. A lesion miss rate of 3.1% and under-representation of lesions on core samples highlight the continued need for multidisciplinary collaboration and selective use of diagnostic surgical biopsy. © 2015 Royal Australasian College of Surgeons.

  15. Compact, Lightweight, Ceramic Matrix Composite (CMC) Based Acoustic Liners for Reducing Subsonic Jet Aircraft Engine Noise

    Science.gov (United States)

    Kiser, J. Douglas; Grady, Joseph E.; Miller, Christopher J.; Hultgren, Lennart S.; Jones, Michael G.

    2016-01-01

    Recent developments have reduced fan and jet noise contributions to overall subsonic aircraft jet-engine noise. Now, aircraft designers are turning their attention toward reducing engine core noise. The NASA Glenn Research Center and NASA Langley Research Center have teamed to investigate the development of a compact, lightweight acoustic liner based on oxide/oxide ceramic matrix composite (CMC) materials. The NASA team has built upon an existing oxide/oxide CMC sandwich structure concept that provides monotonal noise reduction. Oxide/oxide composites have good high temperature strength and oxidation resistance, which could allow them to perform as core liners at temperatures up to 1000C (1832F), and even higher depending on the selection of the composite constituents. NASA has initiated the evaluation of CMC-based liners that use cells of different lengths (variable-depth channels) or effective lengths to achieve broadband noise reduction. Reducing the overall liner thickness is also a major goal, to minimize the volume occupied by the liner. As a first step toward demonstrating the feasibility of our concepts, an oxide/oxide CMC acoustic testing article with different channel lengths was tested. Our approach, summary of test results, current status, and goals for the future are reported.

  16. Methods for surveillance of noise signals from nuclear power plants using auto power spectra

    International Nuclear Information System (INIS)

    Streich, M.

    1988-01-01

    A survey of methods for noise diagnostics applied in the nuclear power plant 'Bruno Leuschner' for surveillance of primary circuit is given. Considering a special example concept of surveillance of standard deviations is explained. (author)

  17. Center of Cancer Nanotechnology Excellence for Translational Diagnostics

    Science.gov (United States)

    The Center of Cancer Nanotechnology Excellence for Translational Diagnostics, which forms the third cycle CCNE Program at Stanford University, is a consortium that has three highly synchronized Projects and three Cores.

  18. Artificial intelligence system for technical diagnostics of photomasks

    OpenAIRE

    Kozin A. A.; Kozina Yu. Yu.

    2012-01-01

    The developed artificial intelligence system has a high level of noise immunity, so its inclusion in the hardware and software for technical diagnostics of photomasks will reduce the hardware requirements for its execution, and thereby reduce the cost of the complex. As a result it will allow to make a small-scale production profitable.

  19. [Variations in the diagnostic confirmation process between breast cancer mass screening units].

    Science.gov (United States)

    Natal, Carmen; Fernández-Somoano, Ana; Torá-Rocamora, Isabel; Tardón, Adonina; Castells, Xavier

    2016-01-01

    To analyse variations in the diagnostic confirmation process between screening units, variations in the outcome of each episode and the relationship between the use of the different diagnostic confirmation tests and the lesion detection rate. Observational study of variability of the standardised use of diagnostic and lesion detection tests in 34 breast cancer mass screening units participating in early-detection programmes in three Spanish regions from 2002-2011. The diagnostic test variation ratio in percentiles 25-75 ranged from 1.68 (further appointments) to 3.39 (fine-needle aspiration). The variation ratio in detection rates of benign lesions, ductal carcinoma in situ and invasive cancer were 2.79, 1.99 and 1.36, respectively. A positive relationship between rates of testing and detection rates was found with fine-needle aspiration-benign lesions (R(2): 0.53), fine-needle aspiration-invasive carcinoma (R(2): 0 28), core biopsy-benign lesions (R(2): 0.64), core biopsy-ductal carcinoma in situ (R(2): 0.61) and core biopsy-invasive carcinoma (R(2): 0.48). Variation in the use of invasive tests between the breast cancer screening units participating in early-detection programmes was found to be significantly higher than variations in lesion detection. Units which conducted more fine-needle aspiration tests had higher benign lesion detection rates, while units that conducted more core biopsies detected more benign lesions and cancer. Copyright © 2016 SESPAS. Published by Elsevier Espana. All rights reserved.

  20. Artificial intelligence system for technical diagnostics of photomasks

    Directory of Open Access Journals (Sweden)

    Kozin A. A.

    2012-02-01

    Full Text Available The developed artificial intelligence system has a high level of noise immunity, so its inclusion in the hardware and software for technical diagnostics of photomasks will reduce the hardware requirements for its execution, and thereby reduce the cost of the complex. As a result it will allow to make a small-scale production profitable.

  1. Deconvolution-based resolution enhancement of chemical ice core records obtained by continuous flow analysis

    DEFF Research Database (Denmark)

    Rasmussen, Sune Olander; Andersen, Katrine K.; Johnsen, Sigfus Johann

    2005-01-01

    Continuous flow analysis (CFA) has become a popular measuring technique for obtaining high-resolution chemical ice core records due to an attractive combination of measuring speed and resolution. However, when analyzing the deeper sections of ice cores or cores from low-accumulation areas...... of the data for high-resolution studies such as annual layer counting. The presented method uses deconvolution techniques and is robust to the presence of noise in the measurements. If integrated into the data processing, it requires no additional data collection. The method is applied to selected ice core...

  2. Bayesian analysis of ion beam diagnostics

    International Nuclear Information System (INIS)

    Toussaint, U. von; Fischer, R.; Dose, V.

    2001-01-01

    Ion beam diagnostics are routinely used for quantitative analysis of the surface composition of mixture materials up to a depth of a few μm. Unfortunately, advantageous properties of the diagnostics, like high depth resolution in combination with a large penetration depth, no destruction of the surface, high sensitivity for large as well as for small atomic numbers, and high sensitivity are mutually exclusive. Among other things, this is due to the ill-conditioned inverse problem of reconstructing depth distributions of the composition elements. Robust results for depth distributions are obtained with adaptive methods in the framework of Bayesian probability theory. The method of adaptive kernels allows for distributions which contain only the significant information of the data while noise fitting is avoided. This is achieved by adaptively reducing the degrees of freedom supporting the distribution. As applications for ion beam diagnostics Rutherford backscattering spectroscopy and particle induced X-ray emission are shown

  3. Low-noise magnetic observatory variometer with race-track sensors

    International Nuclear Information System (INIS)

    Janošek, M; Petrucha, V; Vlk, M

    2016-01-01

    We present a low-noise, high-stability observatory magnetometer with race-track sensors, as developed by the Czech Technical University in Prague for National Observatory of Athens. As opposed to the standard instruments, we used our novel race-track fluxgate sensors with planar oval core which were cut by state-of-the art pico-second UV-laser. The noise performance of the complete electronics and sensor chain is below 6 pT/√Hz @ 1 Hz. The electronics uses 24-bit 200-Hz A/D converter with simultaneous sampling and all digital processing is done in FPGA. The variometer with the sensors mounted on a MACOR cube has been successfully calibrated by scalar method. (paper)

  4. Poisson noise removal with pyramidal multi-scale transforms

    Science.gov (United States)

    Woiselle, Arnaud; Starck, Jean-Luc; Fadili, Jalal M.

    2013-09-01

    In this paper, we introduce a method to stabilize the variance of decimated transforms using one or two variance stabilizing transforms (VST). These VSTs are applied to the 3-D Meyer wavelet pyramidal transform which is the core of the first generation 3D curvelets. This allows us to extend these 3-D curvelets to handle Poisson noise, that we apply to the denoising of a simulated cosmological volume.

  5. Intelligent neural network diagnostic system

    International Nuclear Information System (INIS)

    Mohamed, A.H.

    2010-01-01

    Recently, artificial neural network (ANN) has made a significant mark in the domain of diagnostic applications. Neural networks are used to implement complex non-linear mappings (functions) using simple elementary units interrelated through connections with adaptive weights. The performance of the ANN is mainly depending on their topology structure and weights. Some systems have been developed using genetic algorithm (GA) to optimize the topology of the ANN. But, they suffer from some limitations. They are : (1) The computation time requires for training the ANN several time reaching for the average weight required, (2) Slowness of GA for optimization process and (3) Fitness noise appeared in the optimization of ANN. This research suggests new issues to overcome these limitations for finding optimal neural network architectures to learn particular problems. This proposed methodology is used to develop a diagnostic neural network system. It has been applied for a 600 MW turbo-generator as a case of real complex systems. The proposed system has proved its significant performance compared to two common methods used in the diagnostic applications.

  6. Practical Ranges of Loudness Levels of Various Types of Environmental Noise, Including Traffic Noise, Aircraft Noise, and Industrial Noise

    Directory of Open Access Journals (Sweden)

    Sabine A. Janssen

    2011-05-01

    Full Text Available In environmental noise control one commonly employs the A-weighted sound level as an approximate measure of the effect of noise on people. A measure that is more closely related to direct human perception of noise is the loudness level. At constant A-weighted sound level, the loudness level of a noise signal varies considerably with the shape of the frequency spectrum of the noise signal. In particular the bandwidth of the spectrum has a large effect on the loudness level, due to the effect of critical bands in the human hearing system. The low-frequency content of the spectrum also has an effect on the loudness level. In this note the relation between loudness level and A-weighted sound level is analyzed for various environmental noise spectra, including spectra of traffic noise, aircraft noise, and industrial noise. From loudness levels calculated for these environmental noise spectra, diagrams are constructed that show the relation between loudness level, A‑weighted sound level, and shape of the spectrum. The diagrams show that the upper limits of the loudness level for broadband environmental noise spectra are about 20 to 40 phon higher than the lower limits for narrowband spectra, which correspond to the loudness levels of pure tones. The diagrams are useful for assessing limitations and potential improvements of environmental noise control methods and policy based on A-weighted sound levels.

  7. Relationship between noise and job stress at a private thread spinning company

    Directory of Open Access Journals (Sweden)

    Andi Mursali

    2009-04-01

    Full Text Available Noise exposure is one of the major occupational hazards in many places, and has several health effects, including hearing loss and psychological effects such as sleep disturbances and mental stress. The objective of this research was to determine the relationship between noise and stress and other risk factors that affect job stress. A cross-sectional comparative design involved a total of 326 workers consisting of 220 workers in high noise conditions and 106 workers in low noise conditions. The data were collected directly from the respondents by filling out the questionnaire on worker characteristics, the stress diagnostic questionnaire, and the symptom checklist 90, through discussions with company management, and by measurement of noise levels. The job stress prevalence in workers in high noise conditions was 55% and in those in low noise conditions 24.5%. The results showed that risk factors such as gender of workers, noise conditions, habitual use of ear plugs, shift work, and work stressors had a significant relationship with job stress. Multivariate analysis indicated that the habit of using earplugs was a dominant risk factor causing job stress. The prevalence of job stress in high noise conditions was higher than that in workers in low noise conditions. Noise conditions have a significant relationship with job stress (OR=2.46; 95% CI 1.33 - 4.55. Workers in high noise conditions who did not always use or never had used ear plugs had a higher chance of experiencing stress than those in low noise conditions who did not need ear plugs (OR=21.76; 95% CI 8.09 - 58.52. This study supported that noise exerts its health effect via stress, since noise often raise stress in various ways.

  8. Diagnostic imaging in pregraduate integrated curricula

    International Nuclear Information System (INIS)

    Kainberger, F.; Kletter, K.

    2007-01-01

    Pregraduate medical curricula are currently undergoing a reform process that is moving away from a traditional discipline-related structure and towards problem-based integrated forms of teaching. Imaging sciences, with their inherently technical advances, are specifically influenced by the effects of paradigm shifts in medical education. The teaching of diagnostic radiology should be based on the definition of three core competencies: in vivo visualization of normal and abnormal morphology and function, diagnostic reasoning, and interventional treatment. On the basis of these goals, adequate teaching methods and e-learning tools should be implemented by focusing on case-based teaching. Teaching materials used in the fields of normal anatomy, pathology, and clinical diagnosis may help diagnostic radiology to play a central role in modern pregraduate curricula. (orig.)

  9. [Diagnostic imaging in pregraduate integrated curricula].

    Science.gov (United States)

    Kainberger, F; Kletter, K

    2007-11-01

    Pregraduate medical curricula are currently undergoing a reform process that is moving away from a traditional discipline-related structure and towards problem-based integrated forms of teaching. Imaging sciences, with their inherently technical advances, are specifically influenced by the effects of paradigm shifts in medical education. The teaching of diagnostic radiology should be based on the definition of three core competencies: in vivo visualization of normal and abnormal morphology and function, diagnostic reasoning, and interventional treatment. On the basis of these goals, adequate teaching methods and e-learning tools should be implemented by focusing on case-based teaching. Teaching materials used in the fields of normal anatomy, pathology, and clinical diagnosis may help diagnostic radiology to play a central role in modern pregraduate curricula.

  10. A study to evaluate the efficacy of image-guided core biopsy in the diagnosis and management of lymphoma-Results in 103 biopsies

    International Nuclear Information System (INIS)

    Vandervelde, C.; Kamani, T.; Varghese, A.; Ramesar, K.; Grace, R.; Howlett, D.C.

    2008-01-01

    The reason for this study was to evaluate the ability of image-guided core biopsy to replace surgical excision by providing sufficient diagnostic and treatment information. All consecutive image-guided core biopsies in patients with a final diagnosis of lymphoma over a 6-year period at our institution were collected retrospectively. Case notes and pathology reports were reviewed and the diagnostic techniques used were recorded. Pathology reports were graded according to their diagnostic completeness and their ability to provide treatment information. Out of a total of 328 instances of lymphoma, 103 image-guided core biopsies were performed in 96 patients. In 78% of these, the diagnostic information obtained from the biopsy provided a fully graded and subtyped diagnosis of lymphoma with sufficient information to initiate therapy. In the head and neck 67% of core biopsies were fully diagnostic for treatment purposes compared to 91% in the thorax, abdomen and pelvis. Image-guided core biopsy has a number of cost and safety advantages over surgical excision biopsy and in suitable cases it can obviate the need for surgery in cases of suspected lymphoma. This is especially relevant for elderly patients and those with poor performance status

  11. A study to evaluate the efficacy of image-guided core biopsy in the diagnosis and management of lymphoma-Results in 103 biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Vandervelde, C. [Department of Radiology, Eastbourne District General Hospital, Kings Drive, Eastbourne, East Sussex BN21 2UD (United Kingdom)], E-mail: clivevandervelde@gmail.com; Kamani, T. [Department of ENT Surgery, Eastbourne District General Hospital, Kings Drive, Eastbourne, East Sussex BN21 2UD (United Kingdom)], E-mail: tkamany@yahoo.com; Varghese, A. [Department of Radiology, Eastbourne District General Hospital, Kings Drive, Eastbourne, East Sussex BN21 2UD (United Kingdom)], E-mail: vargheseajay@hotmail.com; Ramesar, K. [Department of Histopathology, Eastbourne District General Hospital, Kings Drive, Eastbourne, East Sussex BN21 2UD (United Kingdom)], E-mail: keith.ramesar@esht.nhs.uk; Grace, R. [Department of Haematology, Eastbourne District General Hospital, Kings Drive, Eastbourne, East Sussex BN21 2UD (United Kingdom)], E-mail: richard.grace@esht.nhs.uk; Howlett, D.C. [Department of Radiology, Eastbourne District General Hospital, Kings Drive, Eastbourne, East Sussex BN21 2UD (United Kingdom)], E-mail: david.howlett@esht.nhs.uk

    2008-04-15

    The reason for this study was to evaluate the ability of image-guided core biopsy to replace surgical excision by providing sufficient diagnostic and treatment information. All consecutive image-guided core biopsies in patients with a final diagnosis of lymphoma over a 6-year period at our institution were collected retrospectively. Case notes and pathology reports were reviewed and the diagnostic techniques used were recorded. Pathology reports were graded according to their diagnostic completeness and their ability to provide treatment information. Out of a total of 328 instances of lymphoma, 103 image-guided core biopsies were performed in 96 patients. In 78% of these, the diagnostic information obtained from the biopsy provided a fully graded and subtyped diagnosis of lymphoma with sufficient information to initiate therapy. In the head and neck 67% of core biopsies were fully diagnostic for treatment purposes compared to 91% in the thorax, abdomen and pelvis. Image-guided core biopsy has a number of cost and safety advantages over surgical excision biopsy and in suitable cases it can obviate the need for surgery in cases of suspected lymphoma. This is especially relevant for elderly patients and those with poor performance status.

  12. Diagnostic performance of power doppler and ultrasound contrast agents in early imaging-based diagnosis of organ-confined prostate cancer: Is it possible to spare cores with contrast-guided biopsy?

    Energy Technology Data Exchange (ETDEWEB)

    Delgado Oliva, F., E-mail: frandelgol@hotmail.com; Arlandis Guzman, S.; Bonillo García, M.; Broseta Rico, E.; Boronat Tormo, F.

    2016-10-15

    Objectives: To evaluate the diagnostic performance of gray scale transrectal ultrasound-B-mode US (BMUS), power Doppler (PDUS), and sonographic contrast (CEUS) in early imaging-based diagnosis of localized prostate cancer (PCa) and to compare the diagnostic profitability of randomized biopsy (RB), US-targeted prostate biopsy by means of PDUS and CEUS. Material and methods: A single-center, prospective, transversal, epidemiological study was conducted from January 2010 to January 2014. We consecutively included patients who an imaging study of the prostate with BMUS, PDUS, and CEUS was performed, followed by prostate biopsy due to clinical suspicion of prostate cancer (PSA 4–20 ng/mL and/or rectal exam suggestive of malignancy). The diagnostic performance of BMUS, PDUS, and CEUS was determined by calculating the Sensitivity (S), Specificity (Sp), Predictive values (PV), and diagnostic odds ratio (OR) of the diagnosis tests and, for these variables, in the population general and based on their clinical stage according to rectal exam (cT1 and cT2). PCa detection rates determined by means of a randomized 10-core biopsy scheme were compared with detection rates of CEUS-targeted (SonoVue) 2-core biopsies. Results: Of the initial 984 patients, US contrast SonoVue was administered to 179 (18.2%). The PCa detection rate by organ of BMUS/PDUS in the global population was 38% versus 43% in the subpopulation with CEUS. The mean age of the patients was 64.3 ± 7.01 years (95% CI, 63.75–64.70); mean total PSA was 8.9 ± 3.61 ng/mL (95% CI, 8.67–9.13) and the mean prostate volume was 56.2 ± 29 cc (95% CI, 54.2–58.1). The detection rate by organ of targeted biopsy with BMUS, PDUS, and CEUS were as follows: Global population (10.6, 8.2, 24.5%), stage cT1 (5.6, 4.2, 16.4%), and stage cT2 (32.4, 22.3, 43.5%). Comparing the detection rates of the CEUS-targeted biopsy and randomized biopsy, the following results were obtained: Global population (24.5% vs. 41.8%), stage cT1 (16

  13. Diagnostic performance of power doppler and ultrasound contrast agents in early imaging-based diagnosis of organ-confined prostate cancer: Is it possible to spare cores with contrast-guided biopsy?

    International Nuclear Information System (INIS)

    Delgado Oliva, F.; Arlandis Guzman, S.; Bonillo García, M.; Broseta Rico, E.; Boronat Tormo, F.

    2016-01-01

    Objectives: To evaluate the diagnostic performance of gray scale transrectal ultrasound-B-mode US (BMUS), power Doppler (PDUS), and sonographic contrast (CEUS) in early imaging-based diagnosis of localized prostate cancer (PCa) and to compare the diagnostic profitability of randomized biopsy (RB), US-targeted prostate biopsy by means of PDUS and CEUS. Material and methods: A single-center, prospective, transversal, epidemiological study was conducted from January 2010 to January 2014. We consecutively included patients who an imaging study of the prostate with BMUS, PDUS, and CEUS was performed, followed by prostate biopsy due to clinical suspicion of prostate cancer (PSA 4–20 ng/mL and/or rectal exam suggestive of malignancy). The diagnostic performance of BMUS, PDUS, and CEUS was determined by calculating the Sensitivity (S), Specificity (Sp), Predictive values (PV), and diagnostic odds ratio (OR) of the diagnosis tests and, for these variables, in the population general and based on their clinical stage according to rectal exam (cT1 and cT2). PCa detection rates determined by means of a randomized 10-core biopsy scheme were compared with detection rates of CEUS-targeted (SonoVue) 2-core biopsies. Results: Of the initial 984 patients, US contrast SonoVue was administered to 179 (18.2%). The PCa detection rate by organ of BMUS/PDUS in the global population was 38% versus 43% in the subpopulation with CEUS. The mean age of the patients was 64.3 ± 7.01 years (95% CI, 63.75–64.70); mean total PSA was 8.9 ± 3.61 ng/mL (95% CI, 8.67–9.13) and the mean prostate volume was 56.2 ± 29 cc (95% CI, 54.2–58.1). The detection rate by organ of targeted biopsy with BMUS, PDUS, and CEUS were as follows: Global population (10.6, 8.2, 24.5%), stage cT1 (5.6, 4.2, 16.4%), and stage cT2 (32.4, 22.3, 43.5%). Comparing the detection rates of the CEUS-targeted biopsy and randomized biopsy, the following results were obtained: Global population (24.5% vs. 41.8%), stage cT1 (16

  14. Development of An On-Line, Core Power Distribution Monitoring System

    International Nuclear Information System (INIS)

    Tunc ALdemir; Don Miller; Peng Wang

    2007-01-01

    The objective of the proposed work was to develop a software package that can construct in three-dimensional core power distributions using the signals from constant temperature power sensors distributed in the reactor core. The software developed uses a mode-based state/parameter estimation technique that is particularly attractive when there are model uncertainties and/or large signal noise. The software yields the expected value of local power at the detector locations and points in between, as well as the probability distribution of the local power density

  15. Development of An On-Line, Core Power Distribution Monitoring System

    Energy Technology Data Exchange (ETDEWEB)

    Tunc ALdemir; Don Miller; Peng Wang

    2007-10-02

    The objective of the proposed work was to develop a software package that can construct in three-dimensional core power distributions using the signals from constant temperature power sensors distributed in the reactor core. The software developed uses a mode-based state/parameter estmation technique that is particularly attractive when there are model uncertainties and/or large signal noise. The software yields the expected value of local power at the detector locations and points in between, as well as the probability distribution of the local power density

  16. Correlation and flux tilt measurements of coupled-core reactor assemblies

    International Nuclear Information System (INIS)

    Harries, J.R.

    1976-01-01

    The systematics of coupling reactivity and time delay between cores have been investigated with a series of coupled-core assemblies on the AAEC Split-table Critical Facility. The assemblies were similar to the Universities' Training Reactor (UTR), but had graphite coupling region thickness of 450 mm, 600 mm and 800 mm. The coupling reactivity measured by both the cross-correlation of reactor noise and the flux tilt methods was stronger than for the UTRs, but showed a similar trend with core spacing. The cross-correlograms were analysed using the two-node model to derive the time delays between the cores. The time delays were compared with thermal neutron wave propagation, and found to be consistent when the time delays were added to the individual node response-function delays. (author)

  17. Road traffic noise: self-reported noise annoyance versus GIS modelled road traffic noise exposure.

    Science.gov (United States)

    Birk, Matthias; Ivina, Olga; von Klot, Stephanie; Babisch, Wolfgang; Heinrich, Joachim

    2011-11-01

    self-reported road traffic noise annoyance is commonly used in epidemiological studies for assessment of potential health effects. Alternatively, some studies have used geographic information system (GIS) modelled exposure to road traffic noise as an objective parameter. The aim of this study was to analyse the association between noise exposure due to neighbouring road traffic and the noise annoyance of adults, taking other determinants into consideration. parents of 951 Munich children from the two German birth cohorts GINIplus and LISAplus reported their annoyance due to road traffic noise at home. GIS modelled road traffic noise exposure (L(den), maximum within a 50 m buffer) from the noise map of the city of Munich was available for all families. GIS-based calculated distance to the closest major road (≥10,000 vehicles per day) and questionnaire based-information about family income, parental education and the type of the street of residence were explored for their potential influence. An ordered logit regression model was applied. The noise levels (L(den)) and the reported noise annoyance were compared with an established exposure-response function. the correlation between noise annoyance and noise exposure (L(den)) was fair (Spearman correlation r(s) = 0.37). The distance to a major road and the type of street were strong predictors for the noise annoyance. The annoyance modelled by the established exposure-response function and that estimated by the ordered logit model were moderately associated (Pearson's correlation r(p) = 0.50). road traffic noise annoyance was associated with GIS modelled neighbouring road traffic noise exposure (L(den)). The distance to a major road and the type of street were additional explanatory factors of the noise annoyance appraisal.

  18. Diagnostic technology of PWR plant equipment failures

    International Nuclear Information System (INIS)

    Nakamura, Tetsuo; Tanaka, Mamoru; Okamachi, Masao; Taguchi, Shozo; Nagashima, Kazuhiro; Ishikawa, Satoshi

    1985-01-01

    To confirm the soundness of the important facilities in a nuclear power plant contributes to the reliability of the plant operations and improvement of its operation rate. For this purpose, the following diagnostic techniques have been developed. (1). Vibration and loose parts monitoring: Detection of abnormal structural vibrations in the reactor, estimation of its mode, detection of loose parts in the primary system, and estimation of the position and energy of their collisions against the reactor vessel or the like. (2). Valve leak monitoring: Detection of leaks from primary valves in the primary cooling boundary, such as the pressurizer relief valve and safety valve, and estimation of the form of the leaks. (3). Detector noise response diagnosis: Diagnosis of degradation of principal process detectors during plant operation. Furthermore, a diagnostic system incorporating the above diagnostic technology applicable to actual plants has been experimentally manufactured and successfully verified. (author)

  19. Investigation of neural network paradigms for the development of automatic noise diagnostic/reactor surveillance systems

    International Nuclear Information System (INIS)

    Korsah, K.; Uhrig, R.E.

    1991-01-01

    The use of artificial intelligence (AI) techniques as an aid in the maintenance and operation of nuclear power plant systems has been recognized for the past several years, and several applications using expert systems technology currently exist. The authors investigated the backpropagation paradigm for the recognition of neutron noise power spectral density (PSD) signatures as a possible alternative to current methods based on statistical techniques. The goal is to advance the state of the art in the application of noise analysis techniques to monitor nuclear reactor internals. Continuous surveillance of reactor systems for structural degradation can be quite cost-effective because (1) the loss of mechanical integrity of the reactor internal components can be detected at an early stage before severe damage occurs, (2) unnecessary periodic maintenance can be avoided, (3) plant downtime can be reduced to a minimum, (4) a high level of plant safety can be maintained, and (5) it can be used to help justify the extension of a plant's operating license. The initial objectives were to use neutron noise PSD data from a pressurized water reactor, acquired over a period of ∼2 years by the Oak Ridge National Laboratory (ORNL) Power Spectral Density RECognition (PSDREC) system to develop networks that can (1) differentiate between normal neutron spectral data and anomalous spectral data (e.g., malfunctioning instrumentation); and (2) detect significant shifts in the positions of spectral resonances while reducing the effect of small, random shifts (in neutron noise analysis, shifts in the resonance(s) present in a neutron PSD spectrum are the primary means for diagnosing degradation of reactor internals). 11 refs, 8 figs

  20. Judgments of aircraft noise in a traffic noise background

    Science.gov (United States)

    Powell, C. A.; Rice, C. G.

    1975-01-01

    An investigation was conducted to determine subjective response to aircraft noise in different road traffic backgrounds. In addition, two laboratory techniques for presenting the aircraft noise with the background noise were evaluated. For one technique, the background noise was continuous over an entire test session; for the other, the background noise level was changed with each aircraft noise during a session. Subjective response to aircraft noise was found to decrease with increasing background noise level, for a range of typical indoor noise levels. Subjective response was found to be highly correlated with the Noise Pollution Level (NPL) measurement scale.

  1. Diagnostic grand rounds: A new teaching concept to train diagnostic reasoning

    International Nuclear Information System (INIS)

    Stieger, Stefan; Praschinger, Andrea; Kletter, Kurt; Kainberger, Franz

    2011-01-01

    Introduction: Diagnostic reasoning is a core skill in teaching and learning in undergraduate curricula. Diagnostic grand rounds (DGRs) as a subform of grand rounds are intended to train the students' skills in the selection of appropriate tests and in the interpretation of test results. The aim of this study was to test DGRs for their ability to improve diagnostic reasoning by using a pre-post-test design. Methods: During one winter term, all 398 fifth-year students (36.1% male, 63.9% female) solved 23 clinical cases presented in 8 DGRs. In an online questionnaire, a Diagnostic Thinking Inventory (DTI) with 41 items was evaluated for flexibility in thinking and structure of knowledge in memory. Results were correlated with those from a summative multiple-choice knowledge test and of the learning objectives in a logbook. Results: The students' DTI scores in the post-test were significantly higher than those reported in the pre-test. DTI scores at either testing time did not correlate with medical knowledge as assessed by a multiple-choice knowledge test. Abilities acquired during clinical clerkships as documented in a logbook could only account for a small proportion of the increase in the flexibility subscale score. This effect still remained significant after accounting for potential confounders. Conclusion: Establishing DGRs proofed to be an effective way of successfully improving both students' diagnostic reasoning and the ability to select the appropriate test method in routine clinical practice.

  2. Diagnostic grand rounds: A new teaching concept to train diagnostic reasoning

    Energy Technology Data Exchange (ETDEWEB)

    Stieger, Stefan, E-mail: stefan.stieger@univie.ac.at [Department of Basic Psychological Research, School of Psychology, University of Vienna, Liebiggasse 5, A-1010 Vienna (Austria); Praschinger, Andrea, E-mail: andrea.praschinger@meduniwien.ac.at [Core Unit for Medical Education (BEMAW), Medical University of Vienna, Spitalgasse 23, BT87, P.O. 10, A-1097 Vienna (Austria); Kletter, Kurt, E-mail: kurt.kletter@meduniwien.ac.at [Department of Nuclear Medicine, General Hospital of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Kainberger, Franz, E-mail: franz.kainberger@meduniwien.ac.at [Department of Radiology, General Hospital of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria)

    2011-06-15

    Introduction: Diagnostic reasoning is a core skill in teaching and learning in undergraduate curricula. Diagnostic grand rounds (DGRs) as a subform of grand rounds are intended to train the students' skills in the selection of appropriate tests and in the interpretation of test results. The aim of this study was to test DGRs for their ability to improve diagnostic reasoning by using a pre-post-test design. Methods: During one winter term, all 398 fifth-year students (36.1% male, 63.9% female) solved 23 clinical cases presented in 8 DGRs. In an online questionnaire, a Diagnostic Thinking Inventory (DTI) with 41 items was evaluated for flexibility in thinking and structure of knowledge in memory. Results were correlated with those from a summative multiple-choice knowledge test and of the learning objectives in a logbook. Results: The students' DTI scores in the post-test were significantly higher than those reported in the pre-test. DTI scores at either testing time did not correlate with medical knowledge as assessed by a multiple-choice knowledge test. Abilities acquired during clinical clerkships as documented in a logbook could only account for a small proportion of the increase in the flexibility subscale score. This effect still remained significant after accounting for potential confounders. Conclusion: Establishing DGRs proofed to be an effective way of successfully improving both students' diagnostic reasoning and the ability to select the appropriate test method in routine clinical practice.

  3. Acoustic Investigation of Jet Mixing Noise in Dual Stream Nozzles

    Science.gov (United States)

    Khavaran, Abbas; Dahl, Milo D.

    2012-01-01

    In an earlier study, a prediction model for jet noise in dual stream jets was proposed that is founded on velocity scaling laws in single stream jets and similarity features of the mean velocity and turbulent kinetic energy in dual stream flows. The model forms a composite spectrum from four component single-stream jets each believed to represent noise-generation from a distinct region in the actual flow. While the methodology worked effectively at conditions considered earlier, recent examination of acoustic data at some unconventional conditions indicate that further improvements are necessary in order to expand the range of applicability of the model. The present work demonstrates how these predictions compare with experimental data gathered by NASA and industry for the purpose of examining the aerodynamic and acoustic performance of such nozzles for a wide range of core and fan stream conditions. Of particular interest are jets with inverted velocity and temperature profiles and the appearance of a second spectral peak at small aft angles to the jet under such conditions. It is shown that a four-component spectrum succeeds in modeling the second peak when the aft angle refraction effects are properly incorporated into the model. A tradeoff of noise emission takes place between two turbulent regions identified as transition and fully mixed regions as the fan stream velocity exceeds that of the core stream. The effect of nozzle discharge coefficients will also be discussed.

  4. 32-core erbium/ytterbium-doped multicore fiber amplifier for next generation space-division multiplexed transmission system

    DEFF Research Database (Denmark)

    Jain, Saurabh; Castro, Carlos; Jung, Yongmin

    2017-01-01

    We present a high-core-count 32-core multicore erbium/ytterbium-doped fiber amplifier (32c-MC-EYDFA) in a cladding pumped configuration. A side pumping technique is employed for ease of pump coupling in this monolithic all-fiber amplifier. A minimum gain of >17 dB and an average noise figure (NF)...

  5. Quantum Noise Reduction with Pulsed Light in Optical Fibers.

    Science.gov (United States)

    Bergman, Keren

    Optical fibers offer considerable advantages over bulk nonlinear media for the generation of squeezed states. This thesis reports on experimental investigations of reducing quantum noise by means of squeezing in nonlinear fiber optic interferometers. Fibers have low insertion loss which allows for long interaction lengths. High field intensities are easily achieved in the small cores of single mode fibers. Additionally, the nonlinear process employed is self phase modulation or the Kerr effect, whose broad band nature requires no phase matching and can be exploited with ultra-short pulses of high peak intensity. All these advantageous features of fibers result in easily obtained large nonlinear phase shifts and subsequently large squeezing parameters. By the self phase modulation process a correlation is produced between the phase and amplitude fluctuations of the optical field. The attenuated or squeezed quadrature has a lower noise level than the initial level associated with the coherent state field before propagation. The resulting reduced quantum noise quadrature can be utilized to improve the sensitivity of a phase measuring instrument such as an interferometer. Because the Kerr nonlinearity is a degenerate self pumping process, the squeezed noise is at the same frequency as the pump field. Classical pump noise can therefore interfere with the desired measurement of the quantum noise reduction. The most severe noise process is the phase noise caused by thermally induced index modulation of the fiber. This noise termed Guided Acoustic Wave Brillouin Scattering, or GAWBS, by previous researchers is studied and analyzed. Experiments performed to overcome GAWBS successfully with several schemes are described. An experimental demonstration of an interferometric measurement with better sensitivity than the standard quantum limit is described. The results lead to new understandings into the limitations of quantum noise reduction that can be achieved in the

  6. Time-dependent electron temperature diagnostics for high-power aluminum z-pinch plasmas

    International Nuclear Information System (INIS)

    Sanford, T.W.L.; Nash, T.J.; Mock, R.C.

    1996-08-01

    Time-resolved x-ray pinhole photographs and time-integrated radially-resolved x-ray crystal-spectrometer measurements of azimuthally-symmetric aluminum-wire implosions suggest that the densest phase of the pinch is composed of a hot plasma core surrounded by a cooler plasma halo. The slope of the free-bound x-ray continuum, provides a time-resolved, model-independent diagnostic of the core electron temperature. A simultaneous measurement of the time-resolved K-shell line spectra provides the electron temperature of the spatially averaged plasma. Together, the two diagnostics support a 1-D Radiation-Hydrodynamic model prediction of a plasma whose thermalization on axis produces steep radial gradients in temperature, from temperatures in excess of a kilovolt in the core to below a kilovolt in the surrounding plasma halo

  7. Optical signal acquisition and processing in future accelerator diagnostics

    International Nuclear Information System (INIS)

    Jackson, G.P.; Elliott, A.

    1992-01-01

    Beam detectors such as striplines and wall current monitors rely on matched electrical networks to transmit and process beam information. Frequency bandwidth, noise immunity, reflections, and signal to noise ratio are considerations that require compromises limiting the quality of the measurement. Recent advances in fiber optics related technologies have made it possible to acquire and process beam signals in the optical domain. This paper describes recent developments in the application of these technologies to accelerator beam diagnostics. The design and construction of an optical notch filter used for a stochastic cooling system is used as an example. Conceptual ideas for future beam detectors are also presented

  8. Application of neutron noise analysis to a swimming pool research reactor

    International Nuclear Information System (INIS)

    Behringer, K.; Lescano, V.H.; Meier, F.; Phildius, J.; Winkler, H.

    1982-01-01

    This work is part of a programme of establishing practical applications of neutron noise techniques to a swimming pool research reactor and deals with two different items: (1) The identification of local boiling caused e.g. by a partial blockage of the coolant flow in a fuel element. Local boiling can easily lead to a burn-out situation. The onset of boiling can be detected by neutron noise analysis and a boiling detection system is presently under development. (2) The measurement of the time evolution of the reactivity induced by xenon after reactor shut-down by an on-line reactivity meter based on neutron noise analysis. From the data, the prompt neutron decay constant at delayed critical, the equilibrium xenon reactivity worth, and an estimate of the average steady-state power flux in the core before reactor shut-down were obtained. (author)

  9. Numerically modeling Brownian thermal noise in amorphous and crystalline thin coatings

    Science.gov (United States)

    Lovelace, Geoffrey; Demos, Nicholas; Khan, Haroon

    2018-01-01

    Thermal noise is expected to be one of the noise sources limiting the astrophysical reach of Advanced LIGO (once commissioning is complete) and third-generation detectors. Adopting crystalline materials for thin, reflecting mirror coatings, rather than the amorphous coatings used in current-generation detectors, could potentially reduce thermal noise. Understanding and reducing thermal noise requires accurate theoretical models, but modeling thermal noise analytically is especially challenging with crystalline materials. Thermal noise models typically rely on the fluctuation-dissipation theorem, which relates the power spectral density of the thermal noise to an auxiliary elastic problem. In this paper, we present results from a new, open-source tool that numerically solves the auxiliary elastic problem to compute the Brownian thermal noise for both amorphous and crystalline coatings. We employ the open-source deal.ii and PETSc frameworks to solve the auxiliary elastic problem using a finite-element method, adaptive mesh refinement, and parallel processing that enables us to use high resolutions capable of resolving the thin reflective coating. We verify numerical convergence, and by running on up to hundreds of compute cores, we resolve the coating elastic energy in the auxiliary problem to approximately 0.1%. We compare with approximate analytic solutions for amorphous materials, and we verify that our solutions scale as expected with changing beam size, mirror dimensions, and coating thickness. Finally, we model the crystalline coating thermal noise in an experiment reported by Cole et al (2013 Nat. Photon. 7 644–50), comparing our results to a simpler numerical calculation that treats the coating as an ‘effectively amorphous’ material. We find that treating the coating as a cubic crystal instead of as an effectively amorphous material increases the thermal noise by about 3%. Our results are a step toward better understanding and reducing thermal noise to

  10. Soft X-ray Tangential Imaging of the NSTX Core Plasma by Means of a MPGD Pin-hole Camera

    International Nuclear Information System (INIS)

    Pacella, D.; Leigheb, M.; Bellazzini, R.; Brez, A.; Finkenthal, M.; Stutman, D.; Kaita, R.; Sabbagh, S.A.

    2003-01-01

    A fast X-ray system based on a Micro Pattern Gas Detector has been used, for the first time, to investigate emission from the plasma core of the National Spherical Tokamak eXperiment (NSTX) at the Princeton Plasma Physics Laboratory. The results presented in this work demonstrate the capability of such a device to measure with a time resolution of the order of 1 ms the curvature and the elongation of the X-ray iso-emissivity contours, under various plasma conditions. Also, comparisons with the magnetic surface structure calculated by the EFIT code show good agreement between reconstructed flux surface and the soft X-ray emissions (SXR) for poloidal beta values up to 0.6. For greater values of beta, X-ray iso-emissivity contours become circular, while magnetic flux surface reconstructions yield elongation 1.5 < k < 2.2. The X-ray images have been acquired with a (statistical) signal to noise ratio (SNR) per pixel of about 30. Thanks to the direct and efficient X-ray conversion and its operation in a photon counting mode, this new diagnostic tool allows the routine investigation of the plasma core with a sampling rate of 1 kHz and extremely high SNR under all experimental conditions in NSTX

  11. Monitoring and diagnosis in situ: noise analysis; Vigilancia y diagnostico in situ analisis de ruido

    Energy Technology Data Exchange (ETDEWEB)

    Montalvo, C.; Garcia-Berrocal, A.

    2014-04-01

    Predictive maintenance based on surveillance and breakdowns diagnostics can be achieved through the analysis of the noise hidden in the signals. At the beginning noise analysis was development to monitor the power signals coming from neutron detectors. Nowadays its applications are very diverse. For instance: process sensors surveillance such us Resistance Temperature detectors, thermocouples and pressure transmitters, internals vibration monitoring, abnormal vibrations detection, etc. In this work some examples from the literature and from the authors experience are presented. (Author)

  12. RANZAR Body Systems Framework of diagnostic imaging examination descriptors

    International Nuclear Information System (INIS)

    Pitman, Alexander D.; Penlington, Lisa; Doromal, Darren; Vukolova, Natalia; Slater, Gregory

    2014-01-01

    A unified and logical system of descriptors for diagnostic imaging examinations and procedures is a desirable resource for radiology in Australia and New Zealand and is needed to support core activities of RANZCR. Existing descriptor systems available in Australia and New Zealand (including the Medicare DIST and the ACC Schedule) have significant limitations and are inappropriate for broader clinical application. An anatomically based grid was constructed, with anatomical structures arranged in rows and diagnostic imaging modalities arranged in columns (including nuclear medicine and positron emission tomography). The grid was segregated into five body systems. The cells at the intersection of an anatomical structure row and an imaging modality column were populated with short, formulaic descriptors of the applicable diagnostic imaging examinations. Clinically illogical or physically impossible combinations were ‘greyed out’. Where the same examination applied to different anatomical structures, the descriptor was kept identical for the purposes of streamlining. The resulting Body Systems Framework of diagnostic imaging examination descriptors lists all the reasonably common diagnostic imaging examinations currently performed in Australia and New Zealand using a unified grid structure allowing navigation by both referrers and radiologists. The Framework has been placed on the RANZCR website and is available for access free of charge by registered users. The Body Systems Framework of diagnostic imaging examination descriptors is a system of descriptors based on relationships between anatomical structures and imaging modalities. The Framework is now available as a resource and reference point for the radiology profession and to support core College activities.

  13. RANZCR Body Systems Framework of diagnostic imaging examination descriptors.

    Science.gov (United States)

    Pitman, Alexander G; Penlington, Lisa; Doromal, Darren; Slater, Gregory; Vukolova, Natalia

    2014-08-01

    A unified and logical system of descriptors for diagnostic imaging examinations and procedures is a desirable resource for radiology in Australia and New Zealand and is needed to support core activities of RANZCR. Existing descriptor systems available in Australia and New Zealand (including the Medicare DIST and the ACC Schedule) have significant limitations and are inappropriate for broader clinical application. An anatomically based grid was constructed, with anatomical structures arranged in rows and diagnostic imaging modalities arranged in columns (including nuclear medicine and positron emission tomography). The grid was segregated into five body systems. The cells at the intersection of an anatomical structure row and an imaging modality column were populated with short, formulaic descriptors of the applicable diagnostic imaging examinations. Clinically illogical or physically impossible combinations were 'greyed out'. Where the same examination applied to different anatomical structures, the descriptor was kept identical for the purposes of streamlining. The resulting Body Systems Framework of diagnostic imaging examination descriptors lists all the reasonably common diagnostic imaging examinations currently performed in Australia and New Zealand using a unified grid structure allowing navigation by both referrers and radiologists. The Framework has been placed on the RANZCR website and is available for access free of charge by registered users. The Body Systems Framework of diagnostic imaging examination descriptors is a system of descriptors based on relationships between anatomical structures and imaging modalities. The Framework is now available as a resource and reference point for the radiology profession and to support core College activities. © 2014 The Royal Australian and New Zealand College of Radiologists.

  14. [Investigation of noise hazards and hearing status of workers in outdoor quarries].

    Science.gov (United States)

    Zhang, Guoying; Tang, Zhifeng; Yao, Yongping; Wang, Haiying

    2014-08-01

    To investigate the noise hazards in open quarries and to provide a basis for further control of noise hazards. An investigation was performed during 2010 to 2011 among all open quarries in Deqing County of Zhejiang Province, China. The investigation included basic information of the quarries, the occupational health situation and noise intensity at the workplace, and the hearing loss of workers exposed to noise in quarry enterprises. The hearing test results were evaluated based on the Diagnostic criteria of occupational noise-induced hearing loss (GBZ 49-2007). A total of 25 enterprises with open quarries were investigated, of which only 30.4% (17/56) workplaces met the national standard. The median noise level was 92.5 dB (A). Fifty-four (10.6%) out of 508 workers in the 25 enterprises were diagnosed with binaural hearing loss in the initial physical examination, with 18.3% (93/508) under surveillance. The rate of normal hearing among crushing workers, mechanists, drilling workers, and blasting workers ranged between 27.6% and 41.4%, which was significantly lower than that among workers exposed to slight noise hazards (80.0%) or other workers (63.7%) (P drilling workers, and blasting workers most seriously jeopardized. Among crushing workers, those working in the first-line or unprotected second?line positions suffered more than the others. Further measures should be taken by the supervision department and the enterprises to control the noise hazards in open quarries.

  15. Investigations of the influence of feedback and coupling effects on neutron noise in a nuclear reactor

    International Nuclear Information System (INIS)

    Vath, W.

    1975-01-01

    Investigations are described of the influence of a known feedback, i.e., a control loop with known transfer function, on the spectra of neutron chamber signals. Theoretical formulas for the spectra are derived using the point reactor model. These formulas were verified by noise measurements in a zero power reactor. Special attention is given to the noise generated by the control loop, the influence of this feedback noise on the spectra being verified experimentally. In large reactors space dependent transfer functions must be taken into account. As a first approximation to handle the spatial dependence, the afore-mentioned investigations were extended to the two-point reactor model. Corresponding experimental work was done for the Argonaut Reactor Karlsruhe (ARK) with a symmetrical two-slab core loading. Coolant boiling in a BWR was investigated. The boiling must be considered as a feedback mechanism as well as an extrnal reactivity perturbation. In order to simulate the steam bubble content, nitrogen gas was injected into the water moderator of the ARK. By modulating the total gas flow according to the instantaneous reactor power the feedback effect was simulated. The gas flow produced a band-limited, white reactivity noise. The upper break frequency could be used to determine the travelling time of the bubbles through the core. (author)

  16. Error tolerance analysis of wave diagnostic based on coherent modulation imaging in high power laser system

    Science.gov (United States)

    Pan, Xingchen; Liu, Cheng; Zhu, Jianqiang

    2018-02-01

    Coherent modulation imaging providing fast convergence speed and high resolution with single diffraction pattern is a promising technique to satisfy the urgent demands for on-line multiple parameter diagnostics with single setup in high power laser facilities (HPLF). However, the influence of noise on the final calculated parameters concerned has not been investigated yet. According to a series of simulations with twenty different sampling beams generated based on the practical parameters and performance of HPLF, the quantitative analysis based on statistical results was first investigated after considering five different error sources. We found the background noise of detector and high quantization error will seriously affect the final accuracy and different parameters have different sensitivity to different noise sources. The simulation results and the corresponding analysis provide the potential directions to further improve the final accuracy of parameter diagnostics which is critically important to its formal applications in the daily routines of HPLF.

  17. Study of the core compaction effects and its monitoring in sodium cooled fast reactors

    International Nuclear Information System (INIS)

    Zylbersztejn, F.

    2012-01-01

    Conclusions: • On calculation of reactivity impacts of core compaction/flowering: → Upper bound of the reactivity coefficients for each type of deformation; → Uniform compaction model: significant reactivity impact; Circular symmetric model: small reactivity impact. • On the visibility of these phenomena by the neutron detectors: → The direct monitoring of the core compaction by neutron detector in the BCC is not possible. (the identification that the reactivity perturbations observed are due to variation of the core geometry). Perspectives of solutions: → Improved core design: reducing the effects. → Physical improvements: Steel resistance to deformations (irradiation, flexion); Direct devices: core constraint (prevents deformations). → Additional calculations: Considering more localized deformations; Advanced monitoring with neutron noise (in progress)

  18. Direct-reading dial for noise temperature and noise resistance

    DEFF Research Database (Denmark)

    Diamond, J.M.

    1967-01-01

    An attenuator arrangement for a noise generator is described. The scheme permits direct reading of both noise resistance and noise temperature¿the latter with a choice of source resistance.......An attenuator arrangement for a noise generator is described. The scheme permits direct reading of both noise resistance and noise temperature¿the latter with a choice of source resistance....

  19. Noise-induced cochlear synaptopathy in rhesus monkeys (Macaca mulatta).

    Science.gov (United States)

    Valero, M D; Burton, J A; Hauser, S N; Hackett, T A; Ramachandran, R; Liberman, M C

    2017-09-01

    Cochlear synaptopathy can result from various insults, including acoustic trauma, aging, ototoxicity, or chronic conductive hearing loss. For example, moderate noise exposure in mice can destroy up to ∼50% of synapses between auditory nerve fibers (ANFs) and inner hair cells (IHCs) without affecting outer hair cells (OHCs) or thresholds, because the synaptopathy occurs first in high-threshold ANFs. However, the fiber loss likely impairs temporal processing and hearing-in-noise, a classic complaint of those with sensorineural hearing loss. Non-human primates appear to be less vulnerable to noise-induced hair-cell loss than rodents, but their susceptibility to synaptopathy has not been studied. Because establishing a non-human primate model may be important in the development of diagnostics and therapeutics, we examined cochlear innervation and the damaging effects of acoustic overexposure in young adult rhesus macaques. Anesthetized animals were exposed bilaterally to narrow-band noise centered at 2 kHz at various sound-pressure levels for 4 h. Cochlear function was assayed for up to 8 weeks following exposure via auditory brainstem responses (ABRs) and otoacoustic emissions (OAEs). A moderate loss of synaptic connections (mean of 12-27% in the basal half of the cochlea) followed temporary threshold shifts (TTS), despite minimal hair-cell loss. A dramatic loss of synapses (mean of 50-75% in the basal half of the cochlea) was seen on IHCs surviving noise exposures that produced permanent threshold shifts (PTS) and widespread hair-cell loss. Higher noise levels were required to produce PTS in macaques compared to rodents, suggesting that primates are less vulnerable to hair-cell loss. However, the phenomenon of noise-induced cochlear synaptopathy in primates is similar to that seen in rodents. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Two-detector cross-correlation noise technique and its application in measuring reactor kinetic parameters

    International Nuclear Information System (INIS)

    Lu Guiping; Peng Feng; Yi Jieyi

    1988-01-01

    The two-detector cross-correlation noise technique is a new method of measuring reactor kinetic parameters developed in the sixties. It has the advantages of non-perturbation in core, high signal to noise ratio, low space dependent effect, and simple and reliable in measurement. A special set of cross-correlation analyzer has been prepared for measuring kinetic parameters of several reactor assemblies, such as the High Flux Engineering Test Reactor, its zero power mock up facility and a low enriched uranium light water lattice zero power facility

  1. Noise frame duration, masking potency and whiteness of temporal noise.

    Science.gov (United States)

    Kukkonen, Heljä; Rovamo, Jyrki; Donner, Kristian; Tammikallio, Marja; Raninen, Antti

    2002-09-01

    Because of the limited contrast range, increasing the duration of the noise frame is often the only option for increasing the masking potency of external, white temporal noise. This, however, reduces the high-frequency cutoff beyond which noise is no longer white. This study was conducted to determine the longest noise frame duration that produces the strongest masking effect and still mimics white noise on the detection of sinusoidal flicker. Contrast energy thresholds (E(th)) were measured for flicker at 1.25 to 20 Hz in strong, purely temporal (spatially uniform), additive, external noise. The masking power of white external noise, characterized by its spectral density at zero frequency N0, increases with the duration of the noise frame. For short noise frame durations, E(th) increased in direct proportion to N0, keeping the nominal signal-to-noise ratio [SNR = (E(th)/N0)(0.5)] constant at threshold. The masking effect thus increased with the duration of the noise frame and the noise mimicked white noise. When noise frame duration and N0 increased further, the nominal SNR at threshold started to decrease, indicating that noise no longer mimicked white noise. The minimum number of noise frames per flicker cycle needed to mimic white noise decreased with increasing flicker frequency from 8.3 at 1.25 Hz to 1.6 at 20 Hz. The critical high-frequency cutoff of detection-limiting temporal noise in terms of noise frames per signal cycle depends on the temporal frequency of the signal. This is opposite to the situation in the spatial domain and must be taken into consideration when temporal signals are masked with temporal noise.

  2. Low Noise Research Fan Stage Design

    Science.gov (United States)

    Hobbs, David E.; Neubert, Robert J.; Malmborg, Eric W.; Philbrick, Daniel H.; Spear, David A.

    1995-01-01

    This report describes the design of a Low Noise ADP Research Fan stage. The fan is a variable pitch design which is designed at the cruise pitch condition. Relative to the cruise setting, the blade is closed at takeoff and opened for reverse thrust operation. The fan stage is a split flow design with fan exit guide vanes and core stators. This fan stage design was combined with a nacelle and engine core duct to form a powered fan/nacelle, subscale model. This model is intended for use in aerodynamic performance, acoustic and structural testing in a wind tunnel. The model has a 22-inch outer fan diameter and a hub-to-top ratio of 0.426 which permits the use of existing NASA fan and cowl force balance designs and rig drive system. The design parameters were selected to permit valid acoustic and aerodynamic comparisons with the PW 17-inch rig previously tested under NASA contract. The fan stage design is described in detail. The results of the design axisymmetric analysis at aerodynamic design condition are included. The structural analysis of the fan rotor and attachment is described including the material selections and stress analysis. The blade and attachment are predicted to have adequate low cycle fatigue life, and an acceptable operating range without resonant stress or flutter. The stage was acoustically designed with airfoil counts in the fan exit guide vane and core stator to minimize noise. A fan-FEGV tone analysis developed separately under NASA contract was used to determine these airfoil counts. The fan stage design was matched to a nacelle design to form a fan/nacelle model for wind tunnel testing. The nacelle design was developed under a separate NASA contract. The nacelle was designed with an axisymmetric inlet, cowl and nozzle for convenience in testing and fabrication. Aerodynamic analysis of the nacelle confirmed the required performance at various aircraft operating conditions.

  3. Physics R and D in support of ITER/BPX diagnostic development

    International Nuclear Information System (INIS)

    Donne, A.J.H.; Boivin, R.; Costley, A.E.

    2003-01-01

    The development of diagnostics for a next step burning plasma experiment (BPX) is a major challenge. Within the International Tokamak Physics Activity (ITPA), one Topical Group (TG) specialises in diagnostics and aims to support the development and design of the needed systems. Several diagnostics issues have been identified as 'high priority' and form the focus of current work of the TG. The core of this paper is a presentation and discussion of recent progress in the field of these high priority research topics. Moreover, the status of the recently initiated International Diagnostic Database will be briefly described. (author)

  4. Proposed Diagnostic Criteria for Smartphone Addiction.

    Science.gov (United States)

    Lin, Yu-Hsuan; Chiang, Chih-Lin; Lin, Po-Hsien; Chang, Li-Ren; Ko, Chih-Hung; Lee, Yang-Han; Lin, Sheng-Hsuan

    2016-01-01

    Global smartphone penetration has led to unprecedented addictive behaviors. The aims of this study are to develop diagnostic criteria of smartphone addiction and to examine the discriminative ability and the validity of the diagnostic criteria. We developed twelve candidate criteria for characteristic symptoms of smartphone addiction and four criteria for functional impairment caused by excessive smartphone use. The participants consisted of 281 college students. Each participant was systematically assessed for smartphone-using behaviors by psychiatrist's structured diagnostic interview. The sensitivity, specificity, and diagnostic accuracy of the candidate symptom criteria were analyzed with reference to the psychiatrists' clinical global impression. The optimal model selection with its cutoff point of the diagnostic criteria differentiating the smartphone addicted subjects from non-addicted subjects was then determined by the best diagnostic accuracy. Six symptom criteria model with optimal cutoff point were determined based on the maximal diagnostic accuracy. The proposed smartphone addiction diagnostic criteria consisted of (1) six symptom criteria, (2) four functional impairment criteria and (3) exclusion criteria. Setting three symptom criteria as the cutoff point resulted in the highest diagnostic accuracy (84.3%), while the sensitivity and specificity were 79.4% and 87.5%, respectively. We suggested determining the functional impairment by two or more of the four domains considering the high accessibility and penetration of smartphone use. The diagnostic criteria of smartphone addiction demonstrated the core symptoms "impaired control" paralleled with substance related and addictive disorders. The functional impairment involved multiple domains provide a strict standard for clinical assessment.

  5. Proposed Diagnostic Criteria for Smartphone Addiction.

    Directory of Open Access Journals (Sweden)

    Yu-Hsuan Lin

    Full Text Available Global smartphone penetration has led to unprecedented addictive behaviors. The aims of this study are to develop diagnostic criteria of smartphone addiction and to examine the discriminative ability and the validity of the diagnostic criteria.We developed twelve candidate criteria for characteristic symptoms of smartphone addiction and four criteria for functional impairment caused by excessive smartphone use. The participants consisted of 281 college students. Each participant was systematically assessed for smartphone-using behaviors by psychiatrist's structured diagnostic interview. The sensitivity, specificity, and diagnostic accuracy of the candidate symptom criteria were analyzed with reference to the psychiatrists' clinical global impression. The optimal model selection with its cutoff point of the diagnostic criteria differentiating the smartphone addicted subjects from non-addicted subjects was then determined by the best diagnostic accuracy.Six symptom criteria model with optimal cutoff point were determined based on the maximal diagnostic accuracy. The proposed smartphone addiction diagnostic criteria consisted of (1 six symptom criteria, (2 four functional impairment criteria and (3 exclusion criteria. Setting three symptom criteria as the cutoff point resulted in the highest diagnostic accuracy (84.3%, while the sensitivity and specificity were 79.4% and 87.5%, respectively. We suggested determining the functional impairment by two or more of the four domains considering the high accessibility and penetration of smartphone use.The diagnostic criteria of smartphone addiction demonstrated the core symptoms "impaired control" paralleled with substance related and addictive disorders. The functional impairment involved multiple domains provide a strict standard for clinical assessment.

  6. Diagnostic Yield of CT-Guided Percutaneous Transthoracic Needle Biopsy for Diagnosis of Anterior Mediastinal Masses.

    Science.gov (United States)

    Petranovic, Milena; Gilman, Matthew D; Muniappan, Ashok; Hasserjian, Robert P; Digumarthy, Subba R; Muse, Victorine V; Sharma, Amita; Shepard, Jo-Anne O; Wu, Carol C

    2015-10-01

    The purpose of this study was to evaluate the diagnostic yield and accuracy of CT-guided percutaneous biopsy of anterior mediastinal masses and assess prebiopsy characteristics that may help to select patients with the highest diagnostic yield. Retrospective review of all CT-guided percutaneous biopsies of the anterior mediastinum conducted at our institution from January 2003 through December 2012 was performed to collect data regarding patient demographics, imaging characteristics of biopsied masses, presence of complications, and subsequent surgical intervention or medical treatment (or both). Cytology, core biopsy pathology, and surgical pathology results were recorded. A per-patient analysis was performed using two-tailed t test, Fisher's exact test, and Pearson chi-square test. The study cohort included 52 patients (32 men, 20 women; mean age, 49 years) with mean diameter of mediastinal mass of 6.9 cm. Diagnostic yield of CT-guided percutaneous biopsy was 77% (40/52), highest for thymic neoplasms (100% [11/11]). Non-diagnostic results were seen in 12 of 52 patients (23%), primarily in patients with lymphoma (75% [9/12]). Fine-needle aspiration yielded the correct diagnosis in 31 of 52 patients (60%), and core biopsy had a diagnostic rate of 77% (36/47). None of the core biopsies were discordant with surgical pathology. There was no statistically significant difference between the diagnostic and the nondiagnostic groups in patient age, lesion size, and presence of necrosis. The complication rate was 3.8% (2/52), all small self-resolving pneumothoraces. CT-guided percutaneous biopsy is a safe diagnostic procedure with high diagnostic yield (77%) for anterior mediastinal lesions, highest for thymic neoplasms (100%), and can potentially obviate more invasive procedures.

  7. Tree-structured vector quantization of CT chest scans: Image quality and diagnostic accuracy

    International Nuclear Information System (INIS)

    Cosman, P.C.; Tseng, C.; Gray, R.M.; Olshen, R.A.; Moses, L.E.; Davidson, H.C.; Bergin, C.J.; Riskin, E.A.

    1993-01-01

    The quality of lossy compressed images is often characterized by signal-to-noise ratios, informal tests of subjective quality, or receiver operating characteristic (ROC) curves that include subjective appraisals of the value of an image for a particular application. The authors believe that for medical applications, lossy compressed images should be judged by a more natural and fundamental aspect of relative image quality: their use in making accurate diagnoses. They apply a lossy compression algorithm to medical images, and quantify the quality of the images by the diagnostic performance of radiologists, as well as by traditional signal-to-noise ratios and subjective ratings. The study is unlike previous studies of the effects of lossy compression in that they consider non-binary detection tasks, simulate actual diagnostic practice instead of using paired tests or confidence rankings, use statistical methods that are more appropriate for non-binary clinical data than are the popular ROC curves, and use low-complexity predictive tree-structured vector quantization for compression rather than DCT-based transform codes combined with entropy coding. Their diagnostic tasks are the identification of nodules (tumors) in the lungs and lymphadenopathy in the mediastinum from computerized tomography (CT) chest scans. For the image modality, compression algorithm, and diagnostic tasks they consider, the original 12 bit per pixel (bpp) CT image can be compressed to between 1 bpp and 2 bpp with no significant changes in diagnostic accuracy

  8. Analysis of prostate cancer localization toward improved diagnostic accuracy of transperineal prostate biopsy

    Directory of Open Access Journals (Sweden)

    Yoshiro Sakamoto

    2014-09-01

    Conclusions: The concordance of prostate cancer between prostatectomy specimens and biopsies is comparatively favorable. According to our study, the diagnostic accuracy of transperineal prostate biopsy can be improved in our institute by including the anterior portion of the Apex-Mid and Mid regions in the 12-core biopsy or 16-core biopsy, such that a 4-core biopsy of the anterior portion is included.

  9. Elevated background noise in adult attention deficit hyperactivity disorder is associated with inattention.

    Science.gov (United States)

    Bubl, Emanuel; Dörr, Michael; Riedel, Andreas; Ebert, Dieter; Philipsen, Alexandra; Bach, Michael; Tebartz van Elst, Ludger

    2015-01-01

    Inattention and distractibility are core symptoms of attention deficit hyperactivity disorder (ADHD). Still the neuronal organization is largely unknown. Previously we studied the electrophysiological activity of a distinct neuronal network-the retina-and found no change in stimulus-driven neural activity in patients with ADHD. However there is growing evidence for an elevated non stimulus-driven neural activity, or neuronal background noise, as underlying pathophysiological correlate. To further examine the biological bases that might underlie ADHD and problems with inattention, we performed a new analysis to test the hypothesis of an elevated background noise as underlying neuronal correlate for ADHD and problems with inattention in humans. A direct measure of background noise in patients with ADHD has not been described yet. The retinal background noise was assessed based on pattern electroretinogram (PERG) data in 20 unmedicated ADHD patients and 20 healthy controls. The PERG is an electrophysiological measure for retinal ganglion cell function. ADHD severity was assessed by interview and questionnaire. Noise amplitude was significantly higher (138%) in patients with ADHD compared to the control group (p = 0.0047). Noise amplitude correlated significantly with psychometric measures for ADHD (CAARS) especially inattention (r = 0.44, p = 0.004). The data provide evidence that an elevated background noise is associated with symptoms of inattention in ADHD and support the use of therapeutic interventions that reduce noise and distraction in patients with ADHD.

  10. The Effect of Bypass Nozzle Exit Area on Fan Aerodynamic Performance and Noise in a Model Turbofan Simulator

    Science.gov (United States)

    Hughes, Christopher E.; Podboy, Gary, G.; Woodward, Richard P.; Jeracki, Robert, J.

    2013-01-01

    The design of effective new technologies to reduce aircraft propulsion noise is dependent on identifying and understanding the noise sources and noise generation mechanisms in the modern turbofan engine, as well as determining their contribution to the overall aircraft noise signature. Therefore, a comprehensive aeroacoustic wind tunnel test program was conducted called the Fan Broadband Source Diagnostic Test as part of the NASA Quiet Aircraft Technology program. The test was performed in the anechoic NASA Glenn 9- by 15-Foot Low Speed Wind Tunnel using a 1/5 scale model turbofan simulator which represented a current generation, medium pressure ratio, high bypass turbofan aircraft engine. The investigation focused on simulating in model scale only the bypass section of the turbofan engine. The test objectives were to: identify the noise sources within the model and determine their noise level; investigate several component design technologies by determining their impact on the aerodynamic and acoustic performance of the fan stage; and conduct detailed flow diagnostics within the fan flow field to characterize the physics of the noise generation mechanisms in a turbofan model. This report discusses results obtained for one aspect of the Source Diagnostic Test that investigated the effect of the bypass or fan nozzle exit area on the bypass stage aerodynamic performance, specifically the fan and outlet guide vanes or stators, as well as the farfield acoustic noise level. The aerodynamic performance, farfield acoustics, and Laser Doppler Velocimeter flow diagnostic results are presented for the fan and four different fixed-area bypass nozzle configurations. The nozzles simulated fixed engine operating lines and encompassed the fan stage operating envelope from near stall to cruise. One nozzle was selected as a baseline reference, representing the nozzle area which would achieve the design point operating conditions and fan stage performance. The total area change from

  11. Active noise control in a duct to cancel broadband noise

    Science.gov (United States)

    Chen, Kuan-Chun; Chang, Cheng-Yuan; Kuo, Sen M.

    2017-09-01

    The paper presents cancelling duct noises by using the active noise control (ANC) techniques. We use the single channel feed forward algorithm with feedback neutralization to realize ANC. Several kinds of ducts noises including tonal noises, sweep tonal signals, and white noise had investigated. Experimental results show that the proposed ANC system can cancel these noises in a PVC duct very well. The noise reduction of white noise can be up to 20 dB.

  12. Robotic vehicle uses acoustic sensors for voice detection and diagnostics

    Science.gov (United States)

    Young, Stuart H.; Scanlon, Michael V.

    2000-07-01

    An acoustic sensor array that cues an imaging system on a small tele- operated robotic vehicle was used to detect human voice and activity inside a building. The advantage of acoustic sensors is that it is a non-line of sight (NLOS) sensing technology that can augment traditional LOS sensors such as visible and IR cameras. Acoustic energy emitted from a target, such as from a person, weapon, or radio, will travel through walls and smoke, around corners, and down corridors, whereas these obstructions would cripple an imaging detection system. The hardware developed and tested used an array of eight microphones to detect the loudest direction and automatically setter a camera's pan/tilt toward the noise centroid. This type of system has applicability for counter sniper applications, building clearing, and search/rescue. Data presented will be time-frequency representations showing voice detected within rooms and down hallways at various ranges. Another benefit of acoustics is that it provides the tele-operator some situational awareness clues via low-bandwidth transmission of raw audio data for the operator to interpret with either headphones or through time-frequency analysis. This data can be useful to recognize familiar sounds that might indicate the presence of personnel, such as talking, equipment, movement noise, etc. The same array also detects the sounds of the robot it is mounted on, and can be useful for engine diagnostics and trouble shooting, or for self-noise emanations for stealthy travel. Data presented will characterize vehicle self noise over various surfaces such as tiles, carpets, pavement, sidewalk, and grass. Vehicle diagnostic sounds will indicate a slipping clutch and repeated unexpected application of emergency braking mechanism.

  13. Acoustic detection of a cavitation noise in the French breeder reactor Phenix

    International Nuclear Information System (INIS)

    Brunet, M.; Desprets, A.

    1981-06-01

    The French Phenix reactor is provided with an in-core multi-sensor acoustic surveillance system. But its efficiency with regard to early boiling detection is still to be proven. For lack of boiling events within the core, a cavitating dummy steel subassembly has been loaded into the reactor, as a simulation of boiling signal. Cavitation is controlled through a slow rise of the primary flow in various core conditions: isothermal situation and during a rise of power. Assuming that the signal to noise ratio is of the same order of magnitude for cavitation signals as for boiling ones, the response of several signal processing techniques is evaluated. Pulse connecting seems to be the most efficient conventional method while pattern recognition appears as a promising alternative solution

  14. Effective data-domain noise and streak reduction for X-ray CT

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Zhi; Zamyatin, Alexander A. [Toshiba Medical Research Institute USA, Inc., Vernon Hills, IL (United States); Akino, Naruomi [Toshiba Medical System Corporation, Tokyo (Japan)

    2011-07-01

    Streaks and noise caused by photon starvation can seriously impair the diagnostic value of the CT imaging. Existing processing methods often have several parameters to tune. The parameters can be ad hoc to the data sets. Iterative methods can achieve better results, however, at the cost of more hardware resources or longer processing time. This paper reports a new scheme of adaptive Gaussian filtering, which is based on the diffusion-derived scale-space concept. In scale-space view, filtering by Gaussians of different sizes is similar to decompose the data into a sequence of scales. The scale measure, which is the variance of the filter, should be linearly related to the noise standard deviation instead of the variance of the noise. This is a fundamental deviation in the way of using filters. The new filter has only one parameter that remains stable once tuned. Singlepass processing can usually reach the desired results. (orig.)

  15. Sounds and Noises. A Position Paper on Noise Pollution.

    Science.gov (United States)

    Chapman, Thomas L.

    This position paper focuses on noise pollution and the problems and solutions associated with this form of pollution. The paper is divided into the following five sections: Noise and the Ear, Noise Measurement, III Effects of Noise, Acoustics and Action, and Programs and Activities. The first section identifies noise and sound, the beginnings of…

  16. Retrospective study comparing six - and twelve-core prostate biopsy in detection of prostate cancer

    Directory of Open Access Journals (Sweden)

    Motoi Tobiume

    2008-02-01

    Full Text Available OBJECTIVE: We compared the safety and efficacy of the 12-core biopsy with those of the conventional systematic 6-core biopsy with PSA levels between 4.1 and 20.0 ng/mL. MATERIALS AND METHODS: This study included 428 patients who underwent a 6-core biopsy and 128 patients who underwent a 12-core biopsy. Biopsies were performed transrectally under ultrasound guidance. The 12-core biopsy scheme involved obtaining 6 far lateral cores. RESULTS: For patients with PSA level between 4.1 and 10.1 ng/mL, 47 of the 265 patients who underwent 6-core biopsy and 32 of the 91 patients who underwent a12-core biopsy were diagnosed with prostate cancer (p = 0.0006. Among the patients with a PSA level between 10.1 and 20.0 ng/mL, 48 of 163 patients who underwent the 6-core biopsy and 16 of 37 patients who underwent the 12-core biopsy were diagnosed with prostate cancer (p = 0.0606. Three of the 95 patients who were diagnosed with prostate cancer through the 6-core biopsy and 12 of the 48 patients who were diagnosed through the 12-core biopsy had cancer located in the anterior apex. The 12-core biopsy increased the diagnostic rate in the apex (p = 0.001. No statistically significant differences were found in incidence of complications. CONCLUSION: We concluded that the 12-core biopsy is a safe and more effective procedure for increasing the diagnostic rate of prostate cancer than the 6-core biopsy in patients with PSA level between 4.1 and 10.0 ng/mL, and the most useful anatomical area to be added was found to be cores from the anterior apex.

  17. Noise diagnosis - a method for early detection of failures in a nuclear plant

    International Nuclear Information System (INIS)

    Brinckmann, H.F.

    1981-01-01

    Noise diagnosis constitutes one method for early detection of plant failures. The method is based on the fact that nearly all undesired processes in a nuclear power plant make a measurable contribution to the noise portion of signals. Well-known examples of undesired processes in pressurized water reactors include core-barrel movement, the vibration of control elements, the appearance of loose parts in the coolant flow, and the process of coolant boiling. Each of these processes has been implicated in past nuclear plant failures. In the German Democratic Republic (GDR) P. Liewers and his colleagues have introduced noise analysis systems into the primary circuit of WWER-440 pressurized water reactors (PWR). The most progressive version (RAS-II) has become a prototype for research and routine investigations. This system is described. (author)

  18. Point-of-care diagnostics for niche applications.

    Science.gov (United States)

    Cummins, Brian M; Ligler, Frances S; Walker, Glenn M

    2016-01-01

    Point-of-care or point-of-use diagnostics are analytical devices that provide clinically relevant information without the need for a core clinical laboratory. In this review we define point-of-care diagnostics as portable versions of assays performed in a traditional clinical chemistry laboratory. This review discusses five areas relevant to human and animal health where increased attention could produce significant impact: veterinary medicine, space travel, sports medicine, emergency medicine, and operating room efficiency. For each of these areas, clinical need, available commercial products, and ongoing research into new devices are highlighted. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. System theory in medical diagnostic devices: an overview.

    Science.gov (United States)

    Baura, Gail D

    2006-01-01

    Medical diagnostics refers to testing conducted either in vitro or in vivo to provide critical health care information for risk assessment, early diagnosis, treatment, or disease management. Typical in vivo diagnostic tests include the computed tomography scan, magnetic resonance imaging, and blood pressure screening. Typical in vitro diagnostic tests include cholesterol, Papanicolaou smear, and conventional glucose monitoring tests. Historically, devices associated with both types of diagnostics have used heuristic curve fitting during signal analysis. However, since the early 1990s, a few enterprising engineers and physicians have used system theory to improve their core processing for feature detection and system identification. Current applications include automated Pap smear screening for detection of cervical cancer and diagnosis of Alzheimer's disease. Future applications, such as disease prediction before symptom onset and drug treatment customization, have been catalyzed by the Human Genome Project.

  20. Is stereotactic large-core needle biopsy beneficial prior to surgical treatment in BI-RADS 5 lesions?

    NARCIS (Netherlands)

    Hoorntje, LE; Peeters, PHM; Mali, WPTM; Rinkes, IHMB

    Introduction. Due to screening mammography, more nonpalpable mammographic lesions warrant histological evaluation. Stereotactic large-core needle biopsy (SLCNB) has been shown to be as effective in diagnosing these lesions as diagnostic surgical excision, and has become the preferred diagnostic

  1. Development of in-core measuring method using optical techniques

    International Nuclear Information System (INIS)

    Kakuta, Tsunemi; Shikama, Tatsuo; Narui, Minoru; Sagawa, Tsutomu.

    1994-01-01

    Since applying to more severe radiation environments in nuclear plants, e.g., in-core measuring systems, diagnostics for fusion reactors, radiation related subjects should be considered by more severe radiation and environmental conditions. Owing to this, preliminary studies of heavy neutron irradiation effects on optical fibers are conducted in the core region of fission reactor. Two kinds of SiO 2 core optical fibers, highly pure SiO 2 with OH content core and SiO 2 with fluorine doped core, were irradiated in the core region of Japan Material Testing Reactor (JMTR). Both fibers were irradiated with fast neutron (E>1.0 MeV) fluence of about 1.6x10 19 n/cm 2 and gamma-ray doses of 3.3x10 9 Gy. The optical absorption and the light-emission spectrum were measured in-situ along the irradiation. This paper mainly outlines the fundamental effects of neutron irradiation and discuss the possibility of neutron detection in the core region of reactor. (J.P.N.)

  2. MCNPX simulations of fast neutron diagnostics for accelerator-driven systems

    Energy Technology Data Exchange (ETDEWEB)

    Habob, Moinul

    2005-12-15

    In accelerator-driven systems, the neutron spectrum will extend all the way up to the incident beam energy, i.e., several hundred MeV or even up to GeV energies. The high neutron energy allows novel diagnostics with a set of measurement techniques that can be used in a sub-critical reactor environment. Such measurements are primarily connected to system safety and validation. This report shows that in-core fast-neutron diagnostics can be employed to monitor changes in the position of incidence of the primary proton beam onto the neutron production target. It has also been shown that fast neutrons can be used to detect temperature-dependent density changes in a liquid lead-bismuth target. Fast neutrons can escape the system via the beam pipe for the incident proton beam. Out-of-core monitoring of these so called back-streaming neutrons could potentially be used to monitor beam changes if the target has a suitable shape. Moreover, diagnostics of back-streaming neutrons might be used for validation of the system design.

  3. MCNPX simulations of fast neutron diagnostics for accelerator-driven systems

    International Nuclear Information System (INIS)

    Habib, Moinul

    2005-12-01

    In accelerator-driven systems, the neutron spectrum will extend all the way up to the incident beam energy, i.e., several hundred MeV or even up to GeV energies. The high neutron energy allows novel diagnostics with a set of measurement techniques that can be used in a sub-critical reactor environment. Such measurements are primarily connected to system safety and validation. This report shows that in-core fast-neutron diagnostics can be employed to monitor changes in the position of incidence of the primary proton beam onto the neutron production target. It has also been shown that fast neutrons can be used to detect temperature-dependent density changes in a liquid lead-bismuth target. Fast neutrons can escape the system via the beam pipe for the incident proton beam. Out-of-core monitoring of these so called back-streaming neutrons could potentially be used to monitor beam changes if the target has a suitable shape. Moreover, diagnostics of back-streaming neutrons might be used for validation of the system design

  4. Status of ITER neutron diagnostic development

    Science.gov (United States)

    Krasilnikov, A. V.; Sasao, M.; Kaschuck, Yu. A.; Nishitani, T.; Batistoni, P.; Zaveryaev, V. S.; Popovichev, S.; Iguchi, T.; Jarvis, O. N.; Källne, J.; Fiore, C. L.; Roquemore, A. L.; Heidbrink, W. W.; Fisher, R.; Gorini, G.; Prosvirin, D. V.; Tsutskikh, A. Yu.; Donné, A. J. H.; Costley, A. E.; Walker, C. I.

    2005-12-01

    Due to the high neutron yield and the large plasma size many ITER plasma parameters such as fusion power, power density, ion temperature, fast ion energy and their spatial distributions in the plasma core can be measured well by various neutron diagnostics. Neutron diagnostic systems under consideration and development for ITER include radial and vertical neutron cameras (RNC and VNC), internal and external neutron flux monitors (NFMs), neutron activation systems and neutron spectrometers. The two-dimensional neutron source strength and spectral measurements can be provided by the combined RNC and VNC. The NFMs need to meet the ITER requirement of time-resolved measurements of the neutron source strength and can provide the signals necessary for real-time control of the ITER fusion power. Compact and high throughput neutron spectrometers are under development. A concept for the absolute calibration of neutron diagnostic systems is proposed. The development, testing in existing experiments and the engineering integration of all neutron diagnostic systems into ITER are in progress and the main results are presented.

  5. Status of ITER neutron diagnostic development

    International Nuclear Information System (INIS)

    Krasilnikov, A.V.; Sasao, M.; Kaschuck, Yu.A.; Nishitani, T.; Batistoni, P.; Zaveryaev, V.S.; Popovichev, S.; Iguchi, T.; Jarvis, O.N.; Kaellne, J.; Fiore, C.L.; Roquemore, A.L.; Heidbrink, W.W.; Fisher, R.; Gorini, G.; Prosvirin, D.V.; Tsutskikh, A.Yu.; Donne, A.J.H.; Costley, A.E.; Walker, C.I.

    2005-01-01

    Due to the high neutron yield and the large plasma size many ITER plasma parameters such as fusion power, power density, ion temperature, fast ion energy and their spatial distributions in the plasma core can be measured well by various neutron diagnostics. Neutron diagnostic systems under consideration and development for ITER include radial and vertical neutron cameras (RNC and VNC), internal and external neutron flux monitors (NFMs), neutron activation systems and neutron spectrometers. The two-dimensional neutron source strength and spectral measurements can be provided by the combined RNC and VNC. The NFMs need to meet the ITER requirement of time-resolved measurements of the neutron source strength and can provide the signals necessary for real-time control of the ITER fusion power. Compact and high throughput neutron spectrometers are under development. A concept for the absolute calibration of neutron diagnostic systems is proposed. The development, testing in existing experiments and the engineering integration of all neutron diagnostic systems into ITER are in progress and the main results are presented

  6. Status of ITER neutron diagnostic development

    International Nuclear Information System (INIS)

    Sasao, M.; Krasilnikov, A.V.; Kaschuck, Yu.A.; Nishitani, T.; Batistoni, P.; Zaveryaev, V.S.; Popovichev, S.; Jarvis, O.N.; Iguchi, T.; Kaellne, J.; Fiore, C.L.; Roquemore, A.L.; Heidbrink, W.W.; Fisher, R.; Gorini, G.; Donne, A.J.H.; Costley, A.E.; Walker, C.I.

    2005-01-01

    Due to the high neutron yield and the large plasma size many ITER plasma parameters such as fusion power, power density, ion temperature, fast ion energy and their spatial distributions in the plasma core can be well measured by various neutron diagnostics. Neutron diagnostic systems under consideration and development for ITER include: radial and vertical neutron cameras (RNC and VNC), internal and external neutron flux monitors, neutron activation systems and neutron spectrometers. The two-dimensional neutron source strength and spectral measurements can be provided by the combined RNC and VNC. The neutron flux monitors need to meet the ITER requirement of time-resolved measurements of the neutron source strength and can provide the signals necessary for real-time control of the ITER fusion power. Compact and high throughput neutron spectrometers are under development. A concept for the absolute calibration of neutron diagnostic systems is proposed. The development, testing in existing experiments and the engineering integration of all neutron diagnostic systems into ITER are in progress and the main results are presented. (author)

  7. The efficacy of an ultrasound-guided core needle biopsy with an 18G cutting needle for the diagnosis of pancreatic diseases

    International Nuclear Information System (INIS)

    Jung, Sung Hwa; Park, Won Kyu; Chang, Jay Chun; Kim, Jae Woon; Cho, Jae Ho; Jang, Han Won; Lee, Jae Kyo; Choi, Joon Hyuk

    2008-01-01

    The objective of this study is to evaluate the efficacy and safety of an ultrasound-guided core needle biopsy with an 18G cutting needle in patients suspected of having a pancreatic disease by analyzing the diagnostic performance and complication rate. The study population comprised 35 consecutive patients who underwent an ultrasound-guided core needle biopsy using a high-speed biopsy gun accompanied with an 18G cutting-type needle between May of 2001 and October of 2005. The diagnostic performance (i.e., the acquisition rate and diagnostic accuracy) and complications associated with core needle biopsies were evaluated for its efficacy and safety. Thirty-six sessions of ultrasound-guided core needle biopsies were performed in 35 consecutive patients. All patients, except two (serous cystadenoma and autoimmune pancreatitis) were diagnosed with various subtypes of pancreatic cancer. The acquisition rate and diagnostic accuracy were 97% (35/36) and 94% (34/36), respectively. A complication occurred only in one patient (3%), which further proved to be a delayed complication (i.e., needle tract implantation). According to our findings, the ultrasound-guided core needle biopsy is a viable and safe method for the diagnosis of pancreatic diseases. Moreover, it enables the diagnosis of the pancreatic cancer subtype

  8. Concordance between fine-needle aspiration and core biopsies for osseous lesions by lesion imaging appearance and CT attenuation.

    Science.gov (United States)

    Li, John; Weissberg, Zoe; Bevilacqua, Thomas A; Yu, Gordon; Weber, Kristy; Sebro, Ronnie

    2018-04-01

    To compare the concordance between fine-needle aspiration and core biopsies for osseous lesions by lesion imaging appearance and CT attenuation. Retrospective review of 215 FNAs of osseous lesions performed in conjunction with core biopsy at our institution over a 6-year period (2011-2016). FNAs were interpreted independently of core biopsies. We assessed if FNA in conjunction with core biopsy increased diagnostic accuracy compared to core biopsy alone. We also calculated the concordance between FNA and core biopsy by lesion appearance, lesion CT attenuation, lesion histology, lesion location and FNA needle gauge size. Core biopsy alone provided the diagnosis in 207/215 cases (96.3%), however, the FNA provided the diagnosis in the remaining 8/215 cases (3.7%) where the core biopsy was non-diagnostic. There were 154 (71.6%) lytic lesions, 21 (9.8%) blastic lesions, 25 (11.6%) mixed lytic and blastic lesions and 15 (7.0%) lesions that were neither lytic nor blastic. The concordance between FNA and core biopsy for lytic osseous lesions (136/154 cases, 88.3%) was statistically significantly higher than that for blastic osseous lesions (13/21 cases, 61.9%) [P = 4.2 × 10 -3 ; 95% CI (0.02, 0.50)]. The concordance between FNA and core biopsy was higher for low-attenuation- (110/126) than high-attenuation (58/77) lesions (P = 0.028). The concordance between FNA and core biopsy was also higher for metastases (102/119 cases, 85.7%) than non-metastases (78/96, 81.3%) [P = 0.487; 95% CI (- 0.15, 0.065)]. There was no difference in the rate of concordance between FNA and core biopsy by lesion location or FNA needle gauge size (P > 0.05). FNA with core biopsy increases diagnostic rate compared to core biopsy alone or FNA alone. The concordance between FNA and core biopsy is higher for lytic lesions than for blastic lesions; and higher for low-attenuation lesions than for high-attenuation lesions.

  9. Dental flat panel conebeam CT in the evaluation of patients with inflammatory sinonasal disease: Diagnostic efficacy and radiation dose savings.

    Science.gov (United States)

    Leiva-Salinas, C; Flors, L; Gras, P; Más-Estellés, F; Lemercier, P; Patrie, J T; Wintermark, M; Martí-Bonmatí, L

    2014-01-01

    CT is the imaging modality of choice to study the paranasal sinuses; unfortunately, it involves significant radiation dose. Our aim was to assess the diagnostic validity, image quality, and radiation-dose savings of dental conebeam CT in the evaluation of patients with suspected inflammatory disorders of the paranasal sinuses. We prospectively studied 40 patients with suspected inflammatory disorders of the sinuses with dental conebeam CT and standard CT. Two radiologists analyzed the images independently, blinded to clinical information. The image quality of both techniques and the diagnostic validity of dental conebeam CT compared with the reference standard CT were assessed by using 3 different scoring systems. Image noise, signal-to-noise ratio, and contrast-to-noise ratio were calculated for both techniques. The absorbed radiation dose to the lenses and thyroid and parotid glands was measured by using a phantom and dosimeter chips. The effective radiation dose for CT was calculated. All dental conebeam CT scans were judged of diagnostic quality. Compared with CT, the conebeam CT image noise was 37.3% higher (P radiation dose to the lenses and parotid and thyroid glands with conebeam CT was 4%, 7.8%, and 7.3% of the dose delivered to the same organs by conventional CT (P Dental conebeam CT is a valid imaging procedure for the evaluation of patients with inflammatory sinonasal disorders. © 2014 by American Journal of Neuroradiology.

  10. The prediction of noise and installation effects of high-subsonic dual-stream jets in flight

    Science.gov (United States)

    Saxena, Swati

    ( TTR = 2.7) are studied and related to the noise characteristics of the jet. Both flow and noise predictions show good agreement with PIV and microphone measurements. The potential core lengths and nozzle wall boundary characteristics are studied to understand the differences between the numerical potential core lengths as compared to experiments. The flight velocity exponent, m is calculated from the noise reduction in overall sound pressure levels (OASPL, dB) and relative velocity (V j -- Vcf) at all jet inlet (angular) angles. The variation of the exponent, m at lower (50° to 90°) and higher aft inlet angles (120° to 150°) is studied and compared with available measurements. Previous studies have shown a different variation of the exponent with inlet angles while the current numerical data match well with recent experiments conducted on the same nozzle geometry. Today, turbofans are the most efficient engines in service used in almost all major commercial aircraft. Turbofans have a dual-stream exhaust nozzle with primary and secondary flow whose flow and noise characteristics are different from that of single stream jets. A Boeing-designed coaxial nozzle, with area ratio of As/Ap = 3.0, is used to study dual-stream jet noise in the present research. In this configuration, the primary nozzle extends beyond the secondary nozzle, which is representative of large turbofan engines in commercial service. The flow calculations are performed at high subsonic Mach numbers in the primary and secondary nozzles (Mpj = 0.85, Msj = 0.95) with heated core flow, TTRp = 2.26 and unheated fan flow, TTRs = 1.0. The co-flow of Mcf = 0.2 is used. The subscript p, s and amb represent the primary (core) nozzle, the secondary (fan) nozzle, and the ambient flow conditions, respectively. The statistical properties in the primary and secondary shear layers are studied and compared with those of the single stream jets. It has been found that the eddy convection velocity is lower in dual

  11. Noise-induced hearing loss: a recreational noise perspective.

    Science.gov (United States)

    Ivory, Robert; Kane, Rebecca; Diaz, Rodney C

    2014-10-01

    This review will discuss the real-world risk factors involved in noise-induced hearing loss as a result of common and popular recreational activities prone to mid and high levels of noise exposure. Although there are currently no interventional measures available to reverse or mitigate preexisting hearing loss from noise, we discuss the vital importance of hearing loss prevention from noise exposure avoidance and reduction. Despite a seeming understanding of the effects of noise exposure from various recreational activities and devices, a large percentage of the general public who is at risk of such noise-induced hearing loss still chooses to refrain from using hearing protection instruments. While occupational exposures pose the greatest traditional risk to hearing conservation in selected workers, recreational risk factors for noise-induced hearing loss may be more insidious in overall effect given the indifferent attitude of much of the general public and particularly our youths toward hearing protection during recreational activities. Active counseling regarding the consequences of excessive noise exposure and the potential benefits to hearing from usage of hearing protection instruments is critical to providing best possible care in the hearing health professions.

  12. Development of global data warehouse for beam diagnostics at SSRF

    International Nuclear Information System (INIS)

    Lai Longwei; Leng Yongbin; Yan Yingbing; Chen Zhichu

    2015-01-01

    The beam diagnostic system is adequate during the daily operation and machine study at the Shanghai Synchrotron Radiation Facility (SSRF). Without the effective event detecting mechanism, it is difficult to dump and analyze abnormal phenomena such as the global orbital disturbance, the malfunction of the BPM and the noise of the DCCT. The global beam diagnostic data warehouse was built in order to monitor the status of the accelerator and the beam instruments. The data warehouse was designed as a Soft IOC hosted on an independent server. Once abnormal phenomena happen it will be triggered and will store the relevant data for further analysis. The results show that the data warehouse can detect abnormal phenomena of the machine and the beam diagnostic system effectively, and can be used for calculating confidential indicators of the beam instruments. It provides an efficient tool for the improvement of the beam diagnostic system and accelerator. (authors)

  13. Practical ranges of loudness levels of various types of environmental noise, including traffic noise, aircraft noise, and industrial noise

    NARCIS (Netherlands)

    Salomons, E.M.; Janssen, S.A.

    2011-01-01

    In environmental noise control one commonly employs the A-weighted sound level as an approximate measure of the effect of noise on people. A measure that is more closely related to direct human perception of noise is the loudness level. At constant A-weighted sound level, the loudness level of a

  14. Noise Reduction and Correction in the IPNS Linac ESEM

    Science.gov (United States)

    Dooling, J. C.; Brumwell, F. R.; Donley, L.; McMichael, G. E.; Stipp, V. F.

    2004-11-01

    The Energy Spread and Energy Monitor (ESEM) is an on-line, non-intrusive diagnostic used to characterize the output beam from the 200-MHz, 50-MeV IPNS linac. The energy spread is determined from a 3-size, longitudinal emittance measurement; whereas the energy is derived from time of flight (TOF) analysis. Signals are detected on 50-ohm, stripline beam position monitors (BPMs) terminated in their characteristic impedance. Each BPM is constructed with four striplines: top, bottom, left and right. The ESEM signals are taken from the bottom stripline in four separate BPM locations in the 50-MeV transport line between the linac and the synchrotron. Deterministic linac noise is sampled before and after the 70-microsecond macropulse. The noise phasor is vectorially subtracted from the beam signal. Noise subtraction is required at several frequencies, especially the fundamental and fifth harmonics (200 MHz and 1 GHz). It is also necessary to correct for attenuation and dispersion in the co-axial signal cables. Presently, the analysis assumes a single particle distribution to determine energy and energy spread. Work is on-going to allow for more realistic longitudinal distributions to be included in the analysis.

  15. Transient plasma estimation: a noise cancelling/identification approach

    International Nuclear Information System (INIS)

    Candy, J.V.; Casper, T.; Kane, R.

    1985-03-01

    The application of a noise cancelling technique to extract energy storage information from sensors occurring during fusion reactor experiments on the Tandem Mirror Experiment-Upgrade (TMX-U) at the Lawrence Livermore National Laboratory (LLNL) is examined. We show how this technique can be used to decrease the uncertainty in the corresponding sensor measurements used for diagnostics in both real-time and post-experimental environments. We analyze the performance of algorithm on the sensor data and discuss the various tradeoffs. The algorithm suggested is designed using SIG, an interactive signal processing package developed at LLNL

  16. Diagnostic accuracy of contemporary multidetector computed tomography (MDCT) for the detection of lumbar disc herniation

    Energy Technology Data Exchange (ETDEWEB)

    Notohamiprodjo, S.; Stahl, R.; Braunagel, M.; Kazmierczak, P.M.; Thierfelder, K.M.; Treitl, K.M.; Wirth, S. [University Hospital of Munich, LMU Munich, Institute for Clinical Radiology, Munich (Germany); Notohamiprodjo, M. [University Hospital Tuebingen, Eberhard Karls University Tuebingen, Diagnostic and Interventional Radiology, Tuebingen (Germany)

    2017-08-15

    To evaluate the diagnostic accuracy of multidetector CT (MDCT) for detection of lumbar disc herniation with MRI as standard of reference. Patients with low back pain underwent indicated MDCT (128-row MDCT, helical pitch), 60 patients with iterative reconstruction (IR) and 67 patients with filtered back projection (FBP). Lumbar spine MRI (1.5 T) was performed within 1 month. Signal-to-noise ratios (SNR) of cerebrospinal fluid (CSF), annulus fibrosus (AF) and the spinal cord (SC) were determined for all modalities. Two readers independently rated image quality (IQ), diagnostic confidence and accuracy in the diagnosis of lumbar disc herniation using MRI as standard of reference. Inter-reader correlation was assessed with weighted κ. Sensitivity, specificity, precision and accuracy of MDCT for disc protrusion were 98.8%, 96.5%, 97.1%, 97.8% (disc level), 97.7%, 92.9%, 98.6%, 96.9% (patient level). SNR of IR was significantly higher than FBP. IQ was significantly better in IR owing to visually reduced noise and improved delineation of the discs. κ (>0.90) was excellent for both algorithms. MDCT of the lumbar spine yields high diagnostic accuracy for detection of lumbar disc herniation. IR improves image quality so that the provided diagnostic accuracy is principally equivalent to MRI. (orig.)

  17. Effects of a traffic noise background on judgements of aircraft noise

    Science.gov (United States)

    Powell, C. A.; Rice, C. G.

    1974-01-01

    A study was conducted in which subjects judged aircraft noises in the presence of road traffic background noise. Two different techniques for presenting the background noises were evaluated. For one technique, the background noise was continuous over the whole of a test session. For the other, the background noise was changed with each aircraft noise. A range of aircraft noise levels and traffic noise levels were presented to simulate typical indoor levels.

  18. Challenges for Plasma Diagnostic in a Next Step Device (FIRE)

    International Nuclear Information System (INIS)

    Young, Kenneth M.

    2002-01-01

    The physics program of any next-step tokamak such as FIRE [Fusion Ignition Research Experiment] sets demands for plasma measurement which are at least as comprehensive as on present tokamaks, with the additional capabilities needed for control of the plasma and for understanding the effects of the alpha-particles. The diagnostic instrumentation must be able to provide the fine spatial and temporal resolution required for the advanced tokamak plasma scenarios. It must also be able to overcome the effects of neutron- and gamma-induced electrical noise in ceramic components or detectors, and fluorescence and absorption in optical components. There are practical engineering issues of minimizing radiation streaming while providing essential diagnostic access to the plasma. Many diagnostics will require components at or close to the first wall, e.g., ceramics and MI cable for magnetic diagnostics and mirrors for optical diagnostics; these components must be mounted to operate, and survive, i n fluxes which require special material selection. A better set of diagnostics of alpha-particles than that available for the TFTR [Tokamak Fusion Test Reactor] is essential; it must be qualified well before moving into D-T [deuterim-tritium] experiments. A start has been made to assessing the potential implementation of key diagnostics for the FIRE device. The present status is described

  19. Evaluation of noise pollution in oil extracting region of Lavan and the effect of noise enclosure on noise abatement

    Directory of Open Access Journals (Sweden)

    F. Golbabaei

    2007-09-01

    Full Text Available Background and aims   Overexposure to industrial noise pollution induce hearing loss workers. Occupational hearing loss may cause interference whit oral communication, so it may  increase the risk of occupational accidents in workplace as well as affects whit social activities.  This study was conducted on Lavan Island, are of oil extracting regions in the south of Iran. The  object of this study was to evaluate noise pollution and determining the effect of noise enclosure  on noise abatement.   Methods   The noise sources were recognized and noise pressure level was measured by CEL- 440. Noise dose of the exposed workers in high level noise area were measured by CEL 272.   Results   Major noise sources were gas turbines, diesel generators, compressors, fans and gas containing pips, noise contour map revealers that noise level were higher than the recommended national exposure limit. The results of workers noise dose show that their noise exposure were  higher than the recommended value, (p<0.001. Finally, by using the results of noise frequency  analysis of different noise sources, the noise pressure level of each sources was determined in   terms of enclosing them.   Conclusion   By enclosing the noise sources, noise pressure levels can be lowered douse to  acceptable levels but limitation of applying enclosure should be regarded.  

  20. Noise cancellation properties of displacement noise free interferometer

    International Nuclear Information System (INIS)

    Sato, Shuichi; Kawamura, Seiji; Nishizawa, Atsushi; Chen Yanbei

    2010-01-01

    We have demonstrated the practical feasibility of a displacement- and frequency-noise-free laser interferometer (DFI) by partially implementing a recently proposed optical configuration using bi-directional Mach-Zehnder interferometers (MZIs). The noise cancellation efficiency was evaluated by comparing the displacement noise spectrum of the MZIs and the DFI, demonstrating up to 50 dB of noise cancellation. In addition, the possible extension of DFI as QND device is explored.

  1. Coupled core criticality calculations with control rods located in the central reflector region

    Energy Technology Data Exchange (ETDEWEB)

    Sobhy, M [Reactor depatrment, nuclear research center, Inshaas (Egypt)

    1995-10-01

    The reactivity of a coupled core is controlled by a set of control rods distributed in the central reflector region. The reactor contains two compact cores cooled and moderated by light water. Control rods are designed to have reactivity worths sufficient to start, control and shutdown the coupled system. Each core in a coupled system is in subcritical conditions without any absorber then each core needs to the other core to fulfill nuclear chain reaction and to approach the criticality. In this case, each core is considered clean which is suitable for research reactor with low flux disturbance and better neutron economy, in addition to the advantage of disappearing the cut corner fuel baskets. This facilitate the in core fuel management with identical fuel baskets. Hot spots will disappear. This leads to a good heat transfer process. the excess reactivity and the shutdown margin are calculated for some of reflector as coupling region gives sufficient area for coupled core are calculated cost. The fluctuations of reactivity for coupled core are calculated by noise analysis technique and compared with that for rode core. The results show low reactivity perturbation associated with coupled core.

  2. Evaluation of The Value of Core Needle Biopsy in The Diagnosis of a Breast Mass

    Directory of Open Access Journals (Sweden)

    Asieh Sadat Fattahi

    2016-06-01

    Full Text Available Background: Core needle biopsy (CNB with histological findings is regarded as one of the most important diagnostic measures that make preoperative assessment and planning for appropriate treatment possible. The aim of this study was to determine the sensitivity and specificity of core biopsy results in our patients with benign and malignant breast lumps, especially for borderline breast lesions, by using a classification method.Methods: In this study, 116 patients who were referred to the Surgery Clinic of Ghaem Hospital, Mashhad University of Medical Sciences, Mashhad, Iran with breast lump and underwent diagnostic procedures such as mammography and ultrasound were selected. Core needle biopsy (Tru-cut #14 or 16 was performed. After that, excisional biopsy was done. The benign, malignant and unspecified samples obtained by core needle biopsy were evaluated with the samples of the surgical and pathological findings. Then, false positive, false negative, sensitivity, specificity, and diagnostic accuracy of the core needle biopsy method were calculated. Also, the National Health Service Breast Screening Program (NHSBSP classification was employed.Results: The mean age of the participants in this study was 39±13.13 years and the mean tumor size was 2.7 cm. An average of 3.35 biopsies was taken from all patients. Most of the pathology samples taken from CNB and excisional biopsy were compatible with invasive ductal carcinoma. Of the B type classifications, B5 was the most frequent in both methods. Borderline lesions B3 and B4 had a change in their category after surgery. About 2.5% of the samples in core biopsy were inadequate. Skin bruising was the most common core biopsy complication reported. While, the most common complication of excisional biopsy was hematoma. Accuracy, sensitivity, specificity, positive and negative predictive values of the core needle biopsy procedure compared with excisional biopsy was 95.5%, 92.6%, 100%, 100%, and 91

  3. Enhanced vibration diagnostics using vibration signature analysis

    International Nuclear Information System (INIS)

    Ahmed, S.; Shehzad, K.; Zahoor, Y.; Mahmood, A.; Bibi, A.

    2001-01-01

    Symptoms will appear in equipment, as well as in human beings. when 'suffering from sickness. Symptoms of abnormality in equipment are vibration, noise, deformation, temperature, pressure, electric current, crack, wearing, leakage etc. these are called modes of failure. If the mode of failure is vibration then the vibration signature analysis can be effectively used in order to diagnose the machinery problems. Much valuable information is contained within these vibration 'Spectra' or 'Signatures' but is only of use if the analyst can unlock its 'Secrets'. This paper documents a vibration problem in the motor of a centrifugal pump (Type ETA). It focuses mainly on the roll of modern vibration monitoring system in problem analysis. The problem experienced was the motor unstability and noise due to high vibration. Using enhanced vibration signature data, the problem was analyzed. which suggested that the rotor eccentricity was the cause of excessive noise and vibration in the motor. In conclusion, advanced electronic monitoring and diagnostic systems provide powerful information for machine's condition assessment and problem analysis. Appropriate interpretation and use of this information is important for accurate and effective vibration analysis. (author)

  4. Two dimensional radiated power diagnostics on Alcator C-Mod

    International Nuclear Information System (INIS)

    Reinke, M. L.; Hutchinson, I. H.

    2008-01-01

    The radiated power diagnostics for the Alcator C-Mod tokamak have been upgraded to measure two dimensional structure of the photon emissivity profile in order to investigate poloidal asymmetries in the core radiation. Commonly utilized unbiased absolute extreme ultraviolet (AXUV) diode arrays view the plasma along five different horizontal planes. The layout of the diagnostic set is shown and the results from calibrations and recent experiments are discussed. Data showing a significant, 30%-40%, inboard/outboard emissivity asymmetry during ELM-free H-mode are presented. The ability to use AXUV diode arrays to measure absolute radiated power is explored by comparing diode and resistive bolometer-based emissivity profiles for highly radiative L-mode plasmas seeded with argon. Emissivity profiles match in the core but disagree radially outward resulting in an underprediction of P rad of nearly 50% by the diodes compared to P rad determined using resistive bolometers.

  5. Two dimensional radiated power diagnostics on Alcator C-Moda)

    Science.gov (United States)

    Reinke, M. L.; Hutchinson, I. H.

    2008-10-01

    The radiated power diagnostics for the Alcator C-Mod tokamak have been upgraded to measure two dimensional structure of the photon emissivity profile in order to investigate poloidal asymmetries in the core radiation. Commonly utilized unbiased absolute extreme ultraviolet (AXUV) diode arrays view the plasma along five different horizontal planes. The layout of the diagnostic set is shown and the results from calibrations and recent experiments are discussed. Data showing a significant, 30%-40%, inboard/outboard emissivity asymmetry during ELM-free H-mode are presented. The ability to use AXUV diode arrays to measure absolute radiated power is explored by comparing diode and resistive bolometer-based emissivity profiles for highly radiative L-mode plasmas seeded with argon. Emissivity profiles match in the core but disagree radially outward resulting in an underprediction of Prad of nearly 50% by the diodes compared to Prad determined using resistive bolometers.

  6. Masking potency and whiteness of noise at various noise check sizes.

    Science.gov (United States)

    Kukkonen, H; Rovamo, J; Näsänen, R

    1995-02-01

    The masking effect of spatial noise can be increased by increasing either the rms contrast or check size of noise. In this study, the authors investigated the largest noise check size that still mimics the effect of white noise in grating detection and how it depends on the bandwidth and spatial frequency of a grating. The authors measured contrast energy thresholds, E, for vertical cosine gratings at various spatial frequencies and bandwidths. Gratings were embedded in two-dimensional spatial noise. The side length of the square noise checks was varied in the experiments. The spectral density, N(0,0), of white spatial noise at zero frequency was calculated by multiplying the noise check area by the rms contrast of noise squared. The physical signal-to-noise ratio at threshold [E/N(0,0)]0.5 was initially constant but then started to decrease. The largest noise check that still produced a constant physical signal-to-noise ratio at threshold was directly proportional to the spatial frequency. When expressed as a fraction of grating cycle, the largest noise check size depended only on stimulus bandwidth. The smallest number of noise checks per grating cycle needed to mimic the effect of white noise decreased from 4.2 to 2.6 when the number of grating cycles increased from 1 to 64. Spatial noise can be regarded as white in grating detection if there are at least four square noise checks per grating cycle at all spatial frequencies.

  7. Influence of Spanwise Boundary Conditions on Slat Noise Simulations

    Science.gov (United States)

    Lockard, David P.; Choudhari, Meelan M.; Buning, Pieter G.

    2015-01-01

    The slat noise from the 30P/30N high-lift system is being investigated through computational fluid dynamics simulations with the OVERFLOW code in conjunction with a Ffowcs Williams-Hawkings acoustics solver. In the present study, two different spanwise grids are being used to investigate the effect of the spanwise extent and periodicity on the near-field unsteady structures and radiated noise. The baseline grid with periodic boundary conditions has a short span equal to 1/9th of the stowed chord, whereas the other, longer span grid adds stretched grids on both sides of the core, baseline grid to allow inviscid surface boundary conditions at both ends. The results indicate that the near-field mean statistics obtained using the two grids are similar to each other, as are the directivity and spectral shapes of the radiated noise. However, periodicity forces all acoustic waves with less than one wavelength across the span to be two-dimensional, without any variation in the span. The spanwise coherence of the acoustic waves is what is needed to make estimates of the noise that would be radiated from realistic span lengths. Simulations with periodic conditions need spans of at least six slat chords to allow spanwise variation in the low-frequencies associated with the peak of broadband slat noise. Even then, the full influence of the periodicity is unclear, so employing grids with a fine, central region and highly stretched meshes that go to slip walls may be a more efficient means of capturing the spanwise decorrelation of low-frequency acoustic phenomena.

  8. A wideband LNA employing gate-inductive-peaking and noise-canceling techniques in 0.18 μm CMOS

    International Nuclear Information System (INIS)

    Bao Kuan; Fan Xiangning; Li Wei; Zhang Li; Wang Zhigong

    2012-01-01

    This paper presents a wideband low noise amplifier (LNA) for multi-standard radio applications. The low noise characteristic is achieved by the noise-canceling technique while the bandwidth is enhanced by gate-inductive-peaking technique. High-frequency noise performance is consequently improved by the flattened gain over the entire operating frequency band. Fabricated in 0.18 μm CMOS process, the LNA achieves 2.5 GHz of −3 dB bandwidth and 16 dB of gain. The gain variation is within ±0.8 dB from 300 MHz to 2.2 GHz. The measured noise figure (NF) and average IIP3 are 3.4 dB and −2 dBm, respectively. The proposed LNA occupies 0.39 mm 2 core chip area. Operating at 1.8 V, the LNA drains a current of 11.7 mA. (semiconductor integrated circuits)

  9. Non-Markovian noise

    International Nuclear Information System (INIS)

    Fulinski, A.

    1994-01-01

    The properties of non-Markovian noises with exponentially correlated memory are discussed. Considered are dichotomic noise, white shot noise, Gaussian white noise, and Gaussian colored noise. The stationary correlation functions of the non-Markovian versions of these noises are given by linear combinations of two or three exponential functions (colored noises) or of the δ function and exponential function (white noises). The non-Markovian white noises are well defined only when the kernel of the non-Markovian master equation contains a nonzero admixture of a Markovian term. Approximate equations governing the probability densities for processes driven by such non-Markovian noises are derived, including non-Markovian versions of the Fokker-Planck equation and the telegrapher's equation. As an example, it is shown how the non-Markovian nature changes the behavior of the driven linear process

  10. Reactor Core Design and Analysis for a Micronuclear Power Source

    Directory of Open Access Journals (Sweden)

    Hao Sun

    2018-03-01

    Full Text Available Underwater vehicle is designed to ensure the security of country sea boundary, providing harsh requirements for its power system design. Conventional power sources, such as battery and Stirling engine, are featured with low power and short lifetime. Micronuclear reactor power source featured with higher power density and longer lifetime would strongly meet the demands of unmanned underwater vehicle power system. In this paper, a 2.4 MWt lithium heat pipe cooled reactor core is designed for micronuclear power source, which can be applied for underwater vehicles. The core features with small volume, high power density, long lifetime, and low noise level. Uranium nitride fuel with 70% enrichment and lithium heat pipes are adopted in the core. The reactivity is controlled by six control drums with B4C neutron absorber. Monte Carlo code MCNP is used for calculating the power distribution, characteristics of reactivity feedback, and core criticality safety. A code MCORE coupling MCNP and ORIGEN is used to analyze the burnup characteristics of the designed core. The results show that the core life is 14 years, and the core parameters satisfy the safety requirements. This work provides reference to the design and application of the micronuclear power source.

  11. User interface design and system integration aspects of core monitoring systems

    International Nuclear Information System (INIS)

    Berg, O.; Bodal, T.; Hornaes, A.; Porsmyr, J.

    2000-01-01

    The present paper describes our experience with the SCORPIO core monitoring system using generic building blocks for the MMI and system integration. In this context the different layers of the software system are discussed starting with the communication system, interfacing of various modules (e.g. physics codes), administration of several modules and generation of graphical user interfaces for different categories of end-users. A method by which re-use of software components can make the system development and maintenance more efficient is described. Examples are given from different system installation projects. The methodology adopted is considered particularly important in the future, as it is anticipated that core monitoring systems will be expanded with new functions (e.g. information from technical specifications, procedures, noise analysis, etc). Further, efficient coupling of off-line tools for core physics calculations and on-line modules in core monitoring can pave the way for cost savings. (authors)

  12. Prediction of Hydrophobic Cores of Proteins Using Wavelet Analysis.

    Science.gov (United States)

    Hirakawa; Kuhara

    1997-01-01

    Information concerning the secondary structures, flexibility, epitope and hydrophobic regions of amino acid sequences can be extracted by assigning physicochemical indices to each amino acid residue, and information on structure can be derived using the sliding window averaging technique, which is in wide use for smoothing out raw functions. Wavelet analysis has shown great potential and applicability in many fields, such as astronomy, radar, earthquake prediction, and signal or image processing. This approach is efficient for removing noise from various functions. Here we employed wavelet analysis to smooth out a plot assigned to a hydrophobicity index for amino acid sequences. We then used the resulting function to predict hydrophobic cores in globular proteins. We calculated the prediction accuracy for the hydrophobic cores of 88 representative set of proteins. Use of wavelet analysis made feasible the prediction of hydrophobic cores at 6.13% greater accuracy than the sliding window averaging technique.

  13. The effects of noise reduction, sharpening, enhancement, and image magnification on diagnostic accuracy of a photostimulable phosphor system in the detection of non-cavitated approximal dental caries

    International Nuclear Information System (INIS)

    Kajan, Zahra Dalili; Davalloo, Reza Tayefeh; Tavangar, Mayam; Valizade, Fatemeh

    2015-01-01

    Contrast, sharpness, enhancement, and density can be changed in digital systems. The important question is to what extent the changes in these variables affect the accuracy of caries detection. Forty eight extracted human posterior teeth with healthy or proximal caries surfaces were imaged using a photostimulable phosphor (PSP) sensor. All original images were processed using a six-step method: (1) applying 'Sharpening 2' and 'Noise Reduction' processing options to the original images; (2) applying the 'Magnification 1:3' option to the image obtained in the first step; (3) enhancing the original images by using the 'Diagonal/' option; (4) reviewing the changes brought about by the third step of image processing and then, applying 'Magnification 1:3'; (5) applying 'Sharpening UM' to the original images; and (6) analyzing the changes brought about by the fifth step of image processing, and finally, applying 'Magnification 1:3.' Three observers evaluated the images. The tooth sections were evaluated histologically as the gold standard. The diagnostic accuracy of the observers was compared using a chi-squared test. The accuracy levels irrespective of the image processing method ranged from weak (18.8%) to intermediate (54.2%), but the highest accuracy was achieved at the sixth image processing step. The overall diagnostic accuracy level showed a statistically significant difference (p=0.0001). This study shows that the application of 'Sharpening UM' along with the 'Magnification 1:3' processing option improved the diagnostic accuracy and the observer agreement more effectively than the other processing procedures.

  14. The effects of noise reduction, sharpening, enhancement, and image magnification on diagnostic accuracy of a photostimulable phosphor system in the detection of non-cavitated approximal dental caries

    Energy Technology Data Exchange (ETDEWEB)

    Kajan, Zahra Dalili; Davalloo, Reza Tayefeh; Tavangar, Mayam; Valizade, Fatemeh [Faculty of Dentistry, Guilan University of Medical Sciences, Rasht (Iran, Islamic Republic of)

    2015-06-15

    Contrast, sharpness, enhancement, and density can be changed in digital systems. The important question is to what extent the changes in these variables affect the accuracy of caries detection. Forty eight extracted human posterior teeth with healthy or proximal caries surfaces were imaged using a photostimulable phosphor (PSP) sensor. All original images were processed using a six-step method: (1) applying 'Sharpening 2' and 'Noise Reduction' processing options to the original images; (2) applying the 'Magnification 1:3' option to the image obtained in the first step; (3) enhancing the original images by using the 'Diagonal/' option; (4) reviewing the changes brought about by the third step of image processing and then, applying 'Magnification 1:3'; (5) applying 'Sharpening UM' to the original images; and (6) analyzing the changes brought about by the fifth step of image processing, and finally, applying 'Magnification 1:3.' Three observers evaluated the images. The tooth sections were evaluated histologically as the gold standard. The diagnostic accuracy of the observers was compared using a chi-squared test. The accuracy levels irrespective of the image processing method ranged from weak (18.8%) to intermediate (54.2%), but the highest accuracy was achieved at the sixth image processing step. The overall diagnostic accuracy level showed a statistically significant difference (p=0.0001). This study shows that the application of 'Sharpening UM' along with the 'Magnification 1:3' processing option improved the diagnostic accuracy and the observer agreement more effectively than the other processing procedures.

  15. Diagnostic Setup for Characterization of Near-Anode Processes in Hall Thrusters

    International Nuclear Information System (INIS)

    Dorf, L.; Raitses, Y.; Fisch, N.J.

    2003-01-01

    A diagnostic setup for characterization of near-anode processes in Hall-current plasma thrusters consisting of biased and emissive electrostatic probes, high-precision positioning system and low-noise electronic circuitry was developed and tested. Experimental results show that radial probe insertion does not cause perturbations to the discharge and therefore can be used for accurate near-anode measurements

  16. Noise-induced annoyance from transportation noise: short-term responses to a single noise source in a laboratory.

    Science.gov (United States)

    Kim, Jaehwan; Lim, Changwoo; Hong, Jiyoung; Lee, Soogab

    2010-02-01

    An experimental study was performed to compare the annoyances from civil-aircraft noise, military-aircraft noise, railway noise, and road-traffic noise. Two-way within-subjects designs were applied in this research. Fifty-two subjects, who were naive listeners, were given various stimuli with varying levels through a headphone in an anechoic chamber. Regardless of the frequency weighting network, even under the same average energy level, civil-aircraft noise was the most annoying, followed by military-aircraft noise, railway noise, and road-traffic noise. In particular, penalties in the time-averaged, A-weighted sound level (TAL) of about 8, 5, and 5 dB, respectively, were found in the civil-aircraft, military-aircraft, and railway noises. The reason could be clarified through the high-frequency component and the variability in the level. When people were exposed to sounds with the same maximum A-weighted level, a railway bonus of about 3 dB was found. However, transportation noise has been evaluated by the time-averaged A-weighted level in most countries. Therefore, in the present situation, the railway bonus is not acceptable for railway vehicles with diesel-electric engines.

  17. Ultrasound-guided percutaneous core needle biopsy of splenic lesions

    Energy Technology Data Exchange (ETDEWEB)

    Park, SangIk; Shin, Yong Moon; Won, Hyung Jin; Kim, Pyo Nyun; Lee, Moon Gyu [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2017-05-15

    To evaluate the safety and efficacy of ultrasound-guided percutaneous core needle biopsy of splenic lesions. This retrospective study included 30 patients who underwent percutaneous core needle biopsy of their splenic lesions using 18- or 20-gauge needles between January 2001 and July 2016 in a single tertiary care center. The characteristics of the splenic lesions were determined by reviewing the ultrasound and computed tomography examinations. Acquisition rate and diagnostic accuracy were calculated, using pathologic results of the splenectomy specimen, clinical course and/or imaging follow-up as a reference standard. Post-procedure complications were identified from electronic medical records, laboratory findings and computed tomography images. Seventy-three specimens were obtained from the 30 patients and splenectomy was performed in 2 patients. Twenty-nine of the 30 patients had focal splenic lesions, while the remaining patient had homogeneous splenomegaly. Acquisition rate and diagnostic accuracy were 80.0% (24/30) and 76.7% (23/30), respectively. Perisplenic hemorrhage without hemodynamic instability developed in one patient. Ultrasound-guided percutaneous core needle biopsy of splenic lesions is a safe method for achieving a histopathologic diagnosis and can be considered as an alternative to splenectomy in patients with a high risk of splenectomy-related complications.

  18. Ultrasound-guided percutaneous core needle biopsy of splenic lesions

    International Nuclear Information System (INIS)

    Park, SangIk; Shin, Yong Moon; Won, Hyung Jin; Kim, Pyo Nyun; Lee, Moon Gyu

    2017-01-01

    To evaluate the safety and efficacy of ultrasound-guided percutaneous core needle biopsy of splenic lesions. This retrospective study included 30 patients who underwent percutaneous core needle biopsy of their splenic lesions using 18- or 20-gauge needles between January 2001 and July 2016 in a single tertiary care center. The characteristics of the splenic lesions were determined by reviewing the ultrasound and computed tomography examinations. Acquisition rate and diagnostic accuracy were calculated, using pathologic results of the splenectomy specimen, clinical course and/or imaging follow-up as a reference standard. Post-procedure complications were identified from electronic medical records, laboratory findings and computed tomography images. Seventy-three specimens were obtained from the 30 patients and splenectomy was performed in 2 patients. Twenty-nine of the 30 patients had focal splenic lesions, while the remaining patient had homogeneous splenomegaly. Acquisition rate and diagnostic accuracy were 80.0% (24/30) and 76.7% (23/30), respectively. Perisplenic hemorrhage without hemodynamic instability developed in one patient. Ultrasound-guided percutaneous core needle biopsy of splenic lesions is a safe method for achieving a histopathologic diagnosis and can be considered as an alternative to splenectomy in patients with a high risk of splenectomy-related complications

  19. Application of diagnostics to determine motor operated valve operational readiness

    International Nuclear Information System (INIS)

    Eissenberg, D.M.

    1987-01-01

    ORNL has been carrying out an aging assessment of motor-operated valves (MOVs) with the primary objective of recommending diagnostic methods for detecting and trending aging. As a result of experimental investigations at ORNL, it was discovered that the motor current during a valve stroke was a very useful diagnostic parameter for detecting and trending many MOV drive train load variations. The motor current signatures were analyzed at four levels: mean value for a stroke, gross trends during a stroke, transients, and noise frequency spectra. Examples illustrating the use of this technique are presented. The use of motor current signature analysis was also shown to apply to other electric motor driven equipment. Future work includes developing a data base of MOV diagnostics, including criteria for determining the extent of degradation and application of the technique to other LWR motor driven safety equipment

  20. Application of diagnostics to determine motor-operated valve operational readiness

    International Nuclear Information System (INIS)

    Eissenberg, D.M.

    1986-01-01

    ORNL has been carrying out an aging assessment of motor-operated valves (MOVs) with the primary objective of recommending diagnostic methods for detecting and trending aging. As a result of experimental investigations at ORNL, it was discovered that the motor current during a valve stroke was a very useful diagnostic parameter for detecting and trending many MOV drive train load variations. The motor curent signatures were analyzed at four levels: mean value for a stroke, gross trends during a stroke, transients, and noise frequency spectra. Examples illustrating the use of this technique are presented. The use of motor current signature analysis was also shown to apply to other electric motor driven equipment. Future work includes developing a data base of MOV diagnostics, including criteria for determining the extent of degradation and application of the technique to other LWR motor driven safety equipment

  1. Real Time Phase Noise Meter Based on a Digital Signal Processor

    Science.gov (United States)

    Angrisani, Leopoldo; D'Arco, Mauro; Greenhall, Charles A.; Schiano Lo Morille, Rosario

    2006-01-01

    A digital signal-processing meter for phase noise measurement on sinusoidal signals is dealt with. It enlists a special hardware architecture, made up of a core digital signal processor connected to a data acquisition board, and takes advantage of a quadrature demodulation-based measurement scheme, already proposed by the authors. Thanks to an efficient measurement process and an optimized implementation of its fundamental stages, the proposed meter succeeds in exploiting all hardware resources in such an effective way as to gain high performance and real-time operation. For input frequencies up to some hundreds of kilohertz, the meter is capable both of updating phase noise power spectrum while seamlessly capturing the analyzed signal into its memory, and granting as good frequency resolution as few units of hertz.

  2. Environmental noise and noise modelling-some aspects in Malaysian development

    International Nuclear Information System (INIS)

    Leong, Mohd Salman; Mohd Shafiek bin Hj Yaacob

    1994-01-01

    Environmental noise is of growing concern in Malaysia with the increasing awareness of the need for an environmental quality consistent with improved quality of life. While noise is one of the several elements in an Environmental Impact Assessment report, the degree of emphasis in the assessment is not as thorough as other aspects in the EIA study. The measurements, prediction (if at all any), and evaluation tended to be superficial. The paper presents a summary of correct noise descriptors and annoyance assessment parameters appropriate for the evaluation of environmental noise. The paper further highlights current inadequacies in the Environmental Quality Act for noise pollution, and annoyance assessment. Some examples of local noise pollution are presented. A discussion on environmental noise modelling is presented. Examples illustrating environmental noise modelling for a mining operation and a power station are given. It is the authors' recommendation that environmental noise modelling be made mandatory in all EIA studies such that a more definitive assessment could be realised

  3. Annoyance of low frequency noise and traffic noise

    DEFF Research Database (Denmark)

    Mortensen, F.R.; Poulsen, Torben

    2001-01-01

    The annoyance of different low frequency noise sources was determined and compared to the annoyance from traffic noise. Twenty-two subjects participated in laboratory listening tests. The sounds were presented by loudspeakers in a listening room and the spectra of the low frequency noises were...

  4. Electric noise component with density f-1 identified on ISEE 3

    International Nuclear Information System (INIS)

    Hoang, S.; Steinberg, J.L.; Couturier, P.; Feldman, W.C.

    1982-01-01

    An electric noise component with an f - 1 spectrum is observed with the SBH radioastronomy receivers on ISEE 3 at frequencies lower than the plasma frequency f/sub p/. On the Z antenna (electrical length for long waves is 7 m) this component is 5--10 times more intense than the predicted thermal noise level. Its spectral density is proportional to f/sub p/ f - 1 (T/sub c/)/sup 1/2/, where T/sub c/ is the core electron temperature and f is the observing frequency. On the S antenna (90 m tip to tip) the new component is much weaker and most probably represents the high-frequency part of a noise spectrum found by Kellogg (1981) with an antenna of the same length. This author interpreted it as mostly due to electron acoustic waves and Doppler shifted ion acoustic waves, but this interpretation has not been confirmed by more accurate calculations (Couturier et al., 1982). Kellogg's spectrum also shows an f - 1 frequency dependence and, if extrapolated assuming the same law as for the Z antenna, approximately fits our S antenna observations. The S antenna f - 1 noise is deeply spin modulated with the minimum electric field in the direction of the solar wind flow as seen in the spacecraft frame of reference. The modulation factor decreases with increasing frequency, becomes negligible when the new component intensity becomes negligible as compared with thermal noise, and increases with the solar wind velocity. The f - 1 component shows some of the properties which are expected from shot noise (direction of minimum intensity) but its spectral index is -1 while shot noise is supposed to show a spectral index -2

  5. Evaluating noise abatement measures using strategic noise maps

    NARCIS (Netherlands)

    Borst, H.C.; Miedema, H.M.E.; Laan, W.P.N. van der; Lohman, W.J.A.

    2006-01-01

    Noise annoyance due to transportation is widespread in industrialized countries and in urban areas in the developing countries. The European Noise Directive (END) requires an assessment of the noise situation as well as the formulation of action plans for the reduction of the number of people

  6. Feasibility Study on a Neutral Beam Diagnostic Injector for TJ-II

    Energy Technology Data Exchange (ETDEWEB)

    McCarthy, K. J.; Balbin, R.; Lopez-Fraguas, A.

    2003-07-01

    A diagnostic neutral beam system is proposed for the TJ-II stellarator. The main goal of installing such a system in TJ-II is to increase the signal to noise ratio and provide spatial resolution in diagnostic systems based on Charge Exchange Recombination Spectroscopy and Neutral Particle Analysis, while also opening up new opportunities for physics studies in this magnetically confined plasma device. After outlining the unique characteristics of the TJ-II and reviewing available diagnostic injector systems, the compact system selected for TJ-II is presented together with estimates of the resulting increased signal levels Finally other important aspects are discussed, in particular its location and orientation, as well as possible solutions to avoid perturbing the TJ-II magnetic configurations in the heliac device. (Author) 31 refs.

  7. Feasibility Study on a Neutral Beam Diagnostic Injector for TJ-II

    International Nuclear Information System (INIS)

    McCarthy, K. J.; Balbin, R.; Lopez-Fraguas, A.

    2003-01-01

    A diagnostic neutral beam system is proposed for the TJ-II stellarator. The main goal of installing such a system in TJ-II is to increase the signal to noise ratio and provide spatial resolution in diagnostic systems based on Charge Exchange Recombination Spectroscopy and Neutral Particle Analysis, while also opening up new opportunities for physics studies in this magnetically confined plasma device. After outlining the unique characteristics of the TJ-II and reviewing available diagnostic injector systems, the compact system selected for TJ-II is presented together with estimates of the resulting increased signal levels Finally other important aspects are discussed, in particular its location and orientation, as well as possible solutions to avoid perturbing the TJ-II magnetic configurations in the heliac device. (Author) 31 refs

  8. The Effect of Flywheel Unbalance on Gear Noise in the Hydraulic Power Plant Turbo-Generator

    Directory of Open Access Journals (Sweden)

    Tomeh Elias

    2017-01-01

    Full Text Available The Effect of Flywheel Unbalance on Gear Noise in the Hydraulic Power Plant Turbo-Generator. Hydraulic power plants are systems that produce electrical energy with high investment costs. In order to fulfil their goals, investments should create conditions for a safe production of energy in a long lasting and reliable way, and with the required power and quality. These goals are possible to reach by an optional control process linked to a systematic monitoring of the operating machinery state, using the method of vibration diagnostics. Lately, there has been an increase of noise level in the hydraulic power plants.

  9. Identification of multivariate models for noise analysis of nuclear plant

    International Nuclear Information System (INIS)

    Zwingelstein, G.C.; Upadhyaya, B.R.

    1979-01-01

    During the normal operation of a pressurized water reactor, neutron noise analysis with multivariate autoregressive procedures in a valuable diagnostic tool to extract dynamic characteristics for incipient failure detection. The first part of the paper will describe in details the equations for estimating the multivariate autoregressive model matrices and the structure of various matrices. The matrices are estimated by solving a set of matrix operations, called Yule-Walker equations. The selection of optimal model order will also be discussed. Once the optimal parameter set is obtained, simple and fast calculations are used to determine the auto power spectral density, cross spectra, coherence function, phase. In addition the spectra may be decomposed into components being contributed from different noise sources. An application using neutron flux data collected on a nuclear plant will illustrate the efficiency of the method

  10. Noise annoys: effects of noise on breeding great tits depend on personality but not on noise characteristics

    NARCIS (Netherlands)

    Naguib, M.; Van Oers, K.; Braakhuis, A.; Griffioen, M.; De Goede, P.; Waas, J.R.

    2013-01-01

    Anthropogenic noise can have serious implications for animals, especially when they communicate acoustically. Yet, the impacts of noise may depend not only on noise characteristics but also on an individual's coping style or personality. We tested whether noise is more disturbing if it masks

  11. A fuzzy logic intelligent diagnostic system for spacecraft integrated vehicle health management

    Science.gov (United States)

    Wu, G. Gordon

    1995-01-01

    Due to the complexity of future space missions and the large amount of data involved, greater autonomy in data processing is demanded for mission operations, training, and vehicle health management. In this paper, we develop a fuzzy logic intelligent diagnostic system to perform data reduction, data analysis, and fault diagnosis for spacecraft vehicle health management applications. The diagnostic system contains a data filter and an inference engine. The data filter is designed to intelligently select only the necessary data for analysis, while the inference engine is designed for failure detection, warning, and decision on corrective actions using fuzzy logic synthesis. Due to its adaptive nature and on-line learning ability, the diagnostic system is capable of dealing with environmental noise, uncertainties, conflict information, and sensor faults.

  12. Updated design for a low-noise, wideband transimpedance photodiode amplifier

    International Nuclear Information System (INIS)

    Paul, S. F.; Marsala, R.

    2006-01-01

    The high-speed rotation diagnostic developed for Columbia's HBT-EP tokamak requires a high quantum efficiency, very low drift detector/amplifier combination. An updated version of the circuit developed originally for the beam emission spectroscopy experiment on TFTR is being used. A low dark current (2 nA at 15 V bias), low input source capacitance (2 pF) FFD-040 N-type Si photodiode is operated in photoconductive mode. It has a quantum efficiency of 40% at the 468.6 nm (He II line that is being observed). A low-noise field-effect transistor (InterFET IFN152 with e Na =1.2 nV/√Hz) is used to reduce the noise in the transimpedance preamplifier (A250 AMPTEK op-amp) and a very high speed (unity-gain bandwidth=200 MHz) voltage feedback amplifier (LM7171) is used to restore the frequency response up to 100 kHz. This type of detector/amplifier is photon-noise limited at this bandwidth for incident light with a power of >∼2 nW. The circuit has been optimized using SIMETRIX 4.0 SPICE software and a prototype circuit has been tested successfully. Though photomultipliers and avalanche photodiodes can detect much lower light levels, for light levels >2 nW and a 10 kHz bandwidth, this detector/amplifier combination is more sensitive because of the absence of excess (internally generated) noise

  13. A retrospective analysis of ultrasound-guided large core needle ...

    African Journals Online (AJOL)

    A retrospective analysis of ultrasound-guided large core needle biopsies of breast lesions at a regional public hospital in Durban, KwaZulu-Natal, South Africa. ... Objective: To assess the influence of technical variables on the diagnostic yield of breast specimens obtained by using US-LCNB, and the sensitivity of detecting ...

  14. Surveillance of vibrations in PWR

    International Nuclear Information System (INIS)

    Espefaelt, R.; Lorenzen, J.; Aakerhielm, F.

    1980-07-01

    The core of a PWR - including fuel elements, internal structure, control rods and core support structure inside the pressure vessel - is subjected to forces which can cause vibrations. One sensitive means to detect and analyse such vibrations is by means of the noise from incore and excore neutron detector signals. In this project noise recordings have been made on two occasions in the Ringhals 2 plant and the obtained data been analysed using the Studsvik Noise Analysis Program System (SNAPS). The results have been intepreted and a detailed description of the vibrational status of the core and pressure vessel internals has been produced. On the basis of the obtained results it is proposed that neutron signal noise analysis should be performed at each PWR plant in the beginning, middle and end of each fuel cycle and an analysis be made using the methods developed in the project. It would also provide a contribution to a higher degree of preparedness for diagnostic tasks in case of unexpected and abnormal events. (author)

  15. Evidence for the diagnostic criteria of delirium: an update.

    Science.gov (United States)

    Blazer, Dan G; van Nieuwenhuizen, Adrienne O

    2012-05-01

    Since the publication of DSM-III in 1980, the essential criteria for delirium have been reduced progressively through DSM-III-R to DSM-IV. As the field moves toward DSM-V and ICD-11, new data can shed light on the nosological changes that are needed so that diagnostic criteria can reflect empirical data. In this study, we reassess the existing or potential criteria for delirium. Phenomenological studies in recent years have informed the criteria for delirium, including the appropriateness of the term 'consciousness' as a core symptom of the diagnosis, additional symptoms of delirium that are frequent but are not currently part of the diagnostic criteria, subsyndromal delirium, motoric subtypes of delirium (hyperactive, hypoactive), and the association of delirium with dementia. Recent studies suggest that motoric subtypes should be included as a subtype for delirium but that subsyndromal delirium, although a useful research construct, should not be included in clinical diagnostic criteria given the frequent fluctuation in symptoms over short periods. In addition, though the core symptoms are probably adequate to make the diagnosis, clinicians must be aware of the frequency of other symptoms, for symptoms such as profound sleep disturbance or psychotic symptoms may dominate the clinical picture.

  16. The effects of noise reduction technologies on the acceptance of background noise.

    Science.gov (United States)

    Lowery, Kristy Jones; Plyler, Patrick N

    2013-09-01

    Directional microphones (D-Mics) and digital noise reduction (DNR) algorithms are used in hearing aids to reduce the negative effects of background noise on performance. Directional microphones attenuate sounds arriving from anywhere other than the front of the listener while DNR attenuates sounds with physical characteristics of noise. Although both noise reduction technologies are currently available in hearing aids, it is unclear if the use of these technologies in isolation or together affects acceptance of noise and/or preference for the end user when used in various types of background noise. The purpose of the research was to determine the effects of D-Mic, DNR, or the combination of D-Mic and DNR on acceptance of noise and preference when listening in various types of background noise. An experimental study in which subjects were exposed to a repeated measures design was utilized. Thirty adult listeners with mild sloping to moderately severe sensorineural hearing loss participated (mean age 67 yr). Acceptable noise levels (ANLs) were obtained using no noise reduction technologies, D-Mic only, DNR only, and the combination of the two technologies (Combo) for three different background noises (single-talker speech, speech-shaped noise, and multitalker babble) for each listener. In addition, preference rankings of the noise reduction technologies were obtained within each background noise (1 = best, 3 = worst). ANL values were significantly better for each noise reduction technology than baseline; and benefit increased significantly from DNR to D-Mic to Combo. Listeners with higher (worse) baseline ANLs received more benefit from noise reduction technologies than listeners with lower (better) baseline ANLs. Neither ANL values nor ANL benefit values were significantly affected by background noise type; however, ANL benefit with D-Mic and Combo was similar when speech-like noise was present while ANL benefit was greatest for Combo when speech spectrum noise was

  17. Community noise

    Science.gov (United States)

    Bragdon, C. R.

    Airport and community land use planning as they relate to airport noise reduction are discussed. Legislation, community relations, and the physiological effect of airport noise are considered. Noise at the Logan, Los Angeles, and Minneapolis/St. Paul airports is discussed.

  18. Identification of mechanical vibrations in a PWR reactor using neutron noise signal analysis of the standard instrumentation; Identifikacija mehanichkih varijacija analizom signala shuma standardne neutronske instrumentacije PWR reaktora

    Energy Technology Data Exchange (ETDEWEB)

    Kostic, Lj [Institut za Nuklearne Nauke Boris Kidric, Belgrade (Yugoslavia); Runkel, J [Institut fuer Kerntechnik und Zerstoerungsfreie Pruefverfahren, Hannover (Germany)

    1988-07-01

    The neutron noise signals in a PWR power plant were analysed in terms of auto- and cross-power spectral densities, phases and coherences. Core barrel motion, fuel element vibrations and reactivity noise effect due to pressure variations have been monitored and analysed. (author)

  19. Cat Swarm Optimization Based Functional Link Artificial Neural Network Filter for Gaussian Noise Removal from Computed Tomography Images

    Directory of Open Access Journals (Sweden)

    M. Kumar

    2016-01-01

    Full Text Available Gaussian noise is one of the dominant noises, which degrades the quality of acquired Computed Tomography (CT image data. It creates difficulties in pathological identification or diagnosis of any disease. Gaussian noise elimination is desirable to improve the clarity of a CT image for clinical, diagnostic, and postprocessing applications. This paper proposes an evolutionary nonlinear adaptive filter approach, using Cat Swarm Functional Link Artificial Neural Network (CS-FLANN to remove the unwanted noise. The structure of the proposed filter is based on the Functional Link Artificial Neural Network (FLANN and the Cat Swarm Optimization (CSO is utilized for the selection of optimum weight of the neural network filter. The applied filter has been compared with the existing linear filters, like the mean filter and the adaptive Wiener filter. The performance indices, such as peak signal to noise ratio (PSNR, have been computed for the quantitative analysis of the proposed filter. The experimental evaluation established the superiority of the proposed filtering technique over existing methods.

  20. Gradients in giant branch morphology in the core of 47 Tucanae

    Science.gov (United States)

    Bailyn, Charles D.

    1994-01-01

    I describe an algorithm which uses the high spatial resolution of the Hubble Space Telescope to complement the high spatial-to-noise, approximately symmetric point response function, relatively large spatial coverage, and standard filters available from ground based images of crowded fields. Applying this technique to the central regions of the globular cluster 47 Tucanae, I find that the morphology of the giant branch in the core is significantly different from that in more distant regions (r approximately equals 5 to 10 core radii) of the cluster. In particular, there appear to be fewer bright giants in the core, along with an enhanced `asymptotic giant branch' (AGB) sequence. Depletion of giants has been observed in the cores of other dense clusters, and may be due to `stripping' of large stars by stellar encounters and/or mass transfer in binary systems. Central concentrations of true asymptotic giant branch stars are not expected to result from dynamical processes; possibly some of these stars may be evolved blue stragglers.

  1. Analysis of the Vortex Street Generated at the Core-Bypass Lip of a Jet-Engine Nozzle

    Science.gov (United States)

    Nogueira, José; Legrand, Mathieu; Nauri, Sara; Rodríguez, Pedro A.; Lecuona, Antonio

    The reduction of the noise generated by jet-engine aircrafts is of growing concern in the present society. A better understanding of the aircraft noise production and the development of predictive tools is of great interest. Within this framework, the CoJeN (Coaxial Jet Noise) European Project includes the measurement of the flow field and the noise generated by typical turbofan jet-engine nozzles. One of the many aspects of interest is the occasional presence of acoustic tones of a defined frequency, symptomatic of the presence of quasiperiodic coherent structures within the flow. This chapter analyzes the characteristics of a vortex street in the core-bypass lip of one of the nozzles under study. The measurements were made by means of advanced PIV techniques within the above-mentioned project.

  2. Dose classification scheme for digital imaging techniques in diagnostic radiology

    International Nuclear Information System (INIS)

    Hojreh, A.

    2002-04-01

    Purpose: image quality in diagnostic radiology is determined in crucial extent by the signal-noise-ratio, which is proportional to the applied x-ray dose. Onward technological developments in the diagnostic radiology are therefore frequently connected with a dose increase, which subjectively is hardly or even not perceptible. The aim of this work was to define reproducible standards for image quality as a function of dose and expected therapeutical consequence in case of computed tomography of the paranasal sinuses and the upper and lower jaw (dental CT), whereby practical-clinical purposes are considered. Materials and methods: the image quality of computed tomography of the paranasal sinuses and dental CT was determined by standard deviation of the CT-numbers (pixel noise) in a region of interest of the phantom of American Association of Physicists in Medicine (AAPM phantom) and additionally in the patients CT images. The diagnostic quality of the examination was classified on the basis of patients CT images in three dose levels (low dose, standard dose and high dose). Results: the pixel noise of CT of the paranasal sinuses with soft tissue reconstruction amounts to 19.3 Hounsfield units (HU) for low dose, 8.8 HU for standard dose, and below 8 HU for high dose. The pixel noise of the dental CT with bone (high resolution) reconstruction amounts to 344 HU for low dose, 221 HU for standard dose, and below 200 HU for high dose. Suitable indications for low dose CT are the scanning of body regions with high contrast differences, like the bony delimitations of air-filled spaces of the facial bones, and radiological follow-up examinations with dedicated questions such as axis determination in dental implantology, as well as the images of objects with small diameter such as in case of children. The standard dose CT can be recommended for all cases, in which precise staging of the illness plays an indispensable role for the diagnosis and therapy planning. With high dose

  3. Noise Estimation and Quality Assessment of Gaussian Noise Corrupted Images

    Science.gov (United States)

    Kamble, V. M.; Bhurchandi, K.

    2018-03-01

    Evaluating the exact quantity of noise present in an image and quality of an image in the absence of reference image is a challenging task. We propose a near perfect noise estimation method and a no reference image quality assessment method for images corrupted by Gaussian noise. The proposed methods obtain initial estimate of noise standard deviation present in an image using the median of wavelet transform coefficients and then obtains a near to exact estimate using curve fitting. The proposed noise estimation method provides the estimate of noise within average error of +/-4%. For quality assessment, this noise estimate is mapped to fit the Differential Mean Opinion Score (DMOS) using a nonlinear function. The proposed methods require minimum training and yields the noise estimate and image quality score. Images from Laboratory for image and Video Processing (LIVE) database and Computational Perception and Image Quality (CSIQ) database are used for validation of the proposed quality assessment method. Experimental results show that the performance of proposed quality assessment method is at par with the existing no reference image quality assessment metric for Gaussian noise corrupted images.

  4. Report on inter-noise 99; Inter-noise 99 sanka hokok

    Energy Technology Data Exchange (ETDEWEB)

    Koike, H. [Japan Automobile Research Institute Inc., Tsukuba (Japan)

    2000-04-01

    Inter-Noise (International Congress on Noise Control Engineering) is a society on noise/vibration and the control technology. Inter-Noise 99 was held on December 6, 7 and 8, 1999, at Fort Lauderdale, Florida, the U.S. The theme was Noise Control in the New Millennium. The number of the participants registered was 555 (151 from the U.S., 89 from Japan, 248 from European countries, and 69 from Asian/other countries). Dr. Harold Marshall gave a keynote lecture titled Noise Control by Design in the 21st Century - An Architectural Acoustic Perspective. From a standpoint of architectural acoustics, he stated the perspective, subjects, and course of the technical development pertaining to technologies needed in the 21st century. The papers read are mostly from the following fields: measuring technology, military exercise noise, modeling, forecast and simulation, aerodynamic/underwater sound, etc. In the session on the tire noise where the author read a paper, 14 papers were read. The number of the papers read was more than that in 1998, probably influenced by the tire noise regulation in Europe and Japan. (translated by NEDO)

  5. Noise frame duration, masking potency and whiteness of temporal noise

    OpenAIRE

    Kukkonen, Helja; Rovamo, Jyrki; Donner, Kristian; Tammikallio, Marja; Raninen, Antii

    2002-01-01

    PURPOSE. Because of the limited contrast range, increasing the duration of the noise frame is often the only option for increasing the masking potency of external, white temporal noise. This, however, reduces the high-frequency cutoff beyond which noise is no longer white. This study was conducted to determine the longest noise frame duration that produces the strongest masking effect and still mimics white noise on the detection of sinusoidal flicker. \\ud \\ud METHODS. Contrast energy thresho...

  6. Noise

    Science.gov (United States)

    Noise is all around you, from televisions and radios to lawn mowers and washing machines. Normally, you ... sensitive structures of the inner ear and cause noise-induced hearing loss. More than 30 million Americans ...

  7. Effects of adaptive statistical iterative reconstruction on radiation dose reduction and diagnostic accuracy of pediatric abdominal CT

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Sohi; Kim, Myung-Joon; Lee, Mi-Jung [Yonsei University College of Medicine, Department of Radiology and Research Institute of Radiological Science, Severance Children' s Hospital, Seoul (Korea, Republic of); Yoon, Choon-Sik [Yonsei University College of Medicine, Department of Radiology, Gangnam Severance Hospital, Seoul (Korea, Republic of); Kim, Dong Wook; Hong, Jung Hwa [Yonsei University College of Medicine, Biostatistics Collaboration Unit, Seoul (Korea, Republic of)

    2014-12-15

    Since children are more radio-sensitive than adults, there is a need to minimize radiation exposure during CT exams. To evaluate the effects of adaptive statistical iterative reconstruction (ASIR) on radiation dose reduction, image quality and diagnostic accuracy in pediatric abdominal CT. We retrospectively reviewed the abdominal CT examinations of 41 children (24 boys and 17 girls; mean age: 10 years) with a low-dose radiation protocol and reconstructed with ASIR (the ASIR group). We also reviewed routine-dose abdominal CT examinations of 41 age- and sex-matched controls reconstructed with filtered-back projection (control group). Image quality was assessed objectively as noise measured in the liver, spleen and aorta, as well as subjectively by three pediatric radiologists for diagnostic acceptability using a four-point scale. Radiation dose and objective image qualities of each group were compared with the paired t-test. Diagnostic accuracy was evaluated by reviewing follow-up imaging studies and medical records in 2012 and 2013. There was 46.3% dose reduction of size-specific dose estimates in ASIR group (from 13.4 to 7.2 mGy) compared with the control group. Objective noise was higher in the liver, spleen and aorta of the ASIR group (P < 0.001). However, the subjective image quality was average or superior in 84-100% of studies. Only one image was subjectively rated as unacceptable by one reviewer. There was only one case with interpretational error in the control group and none in the ASIR group. Use of the ASIR technique resulted in greater than a 45% reduction in radiation dose without impairing subjective image quality or diagnostic accuracy in pediatric abdominal CT, despite increased objective image noise. (orig.)

  8. Effects of adaptive statistical iterative reconstruction on radiation dose reduction and diagnostic accuracy of pediatric abdominal CT

    International Nuclear Information System (INIS)

    Bae, Sohi; Kim, Myung-Joon; Lee, Mi-Jung; Yoon, Choon-Sik; Kim, Dong Wook; Hong, Jung Hwa

    2014-01-01

    Since children are more radio-sensitive than adults, there is a need to minimize radiation exposure during CT exams. To evaluate the effects of adaptive statistical iterative reconstruction (ASIR) on radiation dose reduction, image quality and diagnostic accuracy in pediatric abdominal CT. We retrospectively reviewed the abdominal CT examinations of 41 children (24 boys and 17 girls; mean age: 10 years) with a low-dose radiation protocol and reconstructed with ASIR (the ASIR group). We also reviewed routine-dose abdominal CT examinations of 41 age- and sex-matched controls reconstructed with filtered-back projection (control group). Image quality was assessed objectively as noise measured in the liver, spleen and aorta, as well as subjectively by three pediatric radiologists for diagnostic acceptability using a four-point scale. Radiation dose and objective image qualities of each group were compared with the paired t-test. Diagnostic accuracy was evaluated by reviewing follow-up imaging studies and medical records in 2012 and 2013. There was 46.3% dose reduction of size-specific dose estimates in ASIR group (from 13.4 to 7.2 mGy) compared with the control group. Objective noise was higher in the liver, spleen and aorta of the ASIR group (P < 0.001). However, the subjective image quality was average or superior in 84-100% of studies. Only one image was subjectively rated as unacceptable by one reviewer. There was only one case with interpretational error in the control group and none in the ASIR group. Use of the ASIR technique resulted in greater than a 45% reduction in radiation dose without impairing subjective image quality or diagnostic accuracy in pediatric abdominal CT, despite increased objective image noise. (orig.)

  9. Accuracy of CT-guided percutaneous core needle biopsy for assessment of pediatric musculoskeletal lesions

    International Nuclear Information System (INIS)

    Hryhorczuk, Anastasia L.; Strouse, Peter J.; Biermann, J.S.

    2011-01-01

    CT-guided percutaneous core needle biopsy has been shown in adults to be an effective diagnostic tool for a large number of musculoskeletal malignancies. To characterize our experience with CT-guided percutaneous core needle biopsy of pediatric bone lesions and determine its utility in diagnosing pediatric osseous lesions, in a population where such lesions are commonly benign. From 2000 to 2009, 61 children underwent 63 CT-guided percutaneous biopsies. Radiological, pathological and clinical records were reviewed. Fourteen biopsies (22%) were performed on malignant lesions, while 49 biopsies (78%) were performed on benign lesions. Forty-nine of the 63 biopsies (78%) were adequate; these children underwent no further tissue sampling. Fourteen of the 63 biopsies (22%) were inadequate or non-conclusive. Of these patients, 12 underwent open biopsy. Retrospective analysis of percutaneous biopsies in these patients demonstrates that 9/12 provided clinically relevant information, and 4/12 patients received final diagnoses that confirmed initial core biopsy findings. No malignancies were diagnosed as benign on percutaneous biopsy. Overall, percutaneous core needle biopsy provided accurate diagnostic information in 84% (53/63) of biopsies. Our results demonstrate that CT-guided percutaneous biopsy is safe and beneficial in children. This study supports the use of CT-guided percutaneous core needle biopsy for primary diagnosis of pediatric bone lesions. (orig.)

  10. Exploring cosmic origins with CORE: Mitigation of systematic effects

    Science.gov (United States)

    Natoli, P.; Ashdown, M.; Banerji, R.; Borrill, J.; Buzzelli, A.; de Gasperis, G.; Delabrouille, J.; Hivon, E.; Molinari, D.; Patanchon, G.; Polastri, L.; Tomasi, M.; Bouchet, F. R.; Henrot-Versillé, S.; Hoang, D. T.; Keskitalo, R.; Kiiveri, K.; Kisner, T.; Lindholm, V.; McCarthy, D.; Piacentini, F.; Perdereau, O.; Polenta, G.; Tristram, M.; Achucarro, A.; Ade, P.; Allison, R.; Baccigalupi, C.; Ballardini, M.; Banday, A. J.; Bartlett, J.; Bartolo, N.; Basak, S.; Baumann, D.; Bersanelli, M.; Bonaldi, A.; Bonato, M.; Boulanger, F.; Brinckmann, T.; Bucher, M.; Burigana, C.; Cai, Z.-Y.; Calvo, M.; Carvalho, C.-S.; Castellano, M. G.; Challinor, A.; Chluba, J.; Clesse, S.; Colantoni, I.; Coppolecchia, A.; Crook, M.; D'Alessandro, G.; de Bernardis, P.; De Zotti, G.; Di Valentino, E.; Diego, J.-M.; Errard, J.; Feeney, S.; Fernandez-Cobos, R.; Finelli, F.; Forastieri, F.; Galli, S.; Genova-Santos, R.; Gerbino, M.; González-Nuevo, J.; Grandis, S.; Greenslade, J.; Gruppuso, A.; Hagstotz, S.; Hanany, S.; Handley, W.; Hernandez-Monteagudo, C.; Hervías-Caimapo, C.; Hills, M.; Keihänen, E.; Kitching, T.; Kunz, M.; Kurki-Suonio, H.; Lamagna, L.; Lasenby, A.; Lattanzi, M.; Lesgourgues, J.; Lewis, A.; Liguori, M.; López-Caniego, M.; Luzzi, G.; Maffei, B.; Mandolesi, N.; Martinez-González, E.; Martins, C. J. A. P.; Masi, S.; Matarrese, S.; Melchiorri, A.; Melin, J.-B.; Migliaccio, M.; Monfardini, A.; Negrello, M.; Notari, A.; Pagano, L.; Paiella, A.; Paoletti, D.; Piat, M.; Pisano, G.; Pollo, A.; Poulin, V.; Quartin, M.; Remazeilles, M.; Roman, M.; Rossi, G.; Rubino-Martin, J.-A.; Salvati, L.; Signorelli, G.; Tartari, A.; Tramonte, D.; Trappe, N.; Trombetti, T.; Tucker, C.; Valiviita, J.; Van de Weijgaert, R.; van Tent, B.; Vennin, V.; Vielva, P.; Vittorio, N.; Wallis, C.; Young, K.; Zannoni, M.

    2018-04-01

    We present an analysis of the main systematic effects that could impact the measurement of CMB polarization with the proposed CORE space mission. We employ timeline-to-map simulations to verify that the CORE instrumental set-up and scanning strategy allow us to measure sky polarization to a level of accuracy adequate to the mission science goals. We also show how the CORE observations can be processed to mitigate the level of contamination by potentially worrying systematics, including intensity-to-polarization leakage due to bandpass mismatch, asymmetric main beams, pointing errors and correlated noise. We use analysis techniques that are well validated on data from current missions such as Planck to demonstrate how the residual contamination of the measurements by these effects can be brought to a level low enough not to hamper the scientific capability of the mission, nor significantly increase the overall error budget. We also present a prototype of the CORE photometric calibration pipeline, based on that used for Planck, and discuss its robustness to systematics, showing how CORE can achieve its calibration requirements. While a fine-grained assessment of the impact of systematics requires a level of knowledge of the system that can only be achieved in a future study phase, the analysis presented here strongly suggests that the main areas of concern for the CORE mission can be addressed using existing knowledge, techniques and algorithms.

  11. A study on the noise characteristics of polymer ball bearings under various lubrication conditions

    Science.gov (United States)

    Dinç, S. K.; Temiz, V.; Kamburoǧlu, E.

    2013-12-01

    Polymer bearings are generally praised by the manufacturers for running silently. However such statements never go beyond qualitative assumptions. Therefore, studying polymer ball bearing noise would have been meaningful solely on the perspective of silent running machinery. On the other hand, the service life of a polymer ball bearing is unpredictable and there's no preventive maintenance practice that provides data regarding the condition of a polymer ball bearing. In this study, we assume that an investigation of their noise characteristics could also reveal clues concerning their performances. The main objective of this study is to determine the noise characteristics of polymer ball bearings lubricated with different lubricant greases of varying viscosity grades through experimental means. Sound pressure level measurements of SKF brand polymer bearings with polypropylene rings, polypropylene cage and glass balls were made with a 1/2 inch microphone in 1/3-octave bands, at frequencies up to 12.5 kHz, under various radial loads and rotational speeds. The bearings were mounted on a shaft driven by an AC motor with stepless speed control, adjustable between 0 - 1400 rpm. The ball bearings were running inside an acoustic chamber designed for the insulation of environmental noise and the noise of the motor at target frequencies. The resulting sound pressure level spectra were evaluated and the effects of the lubrication conditions on the noise of the ball bearing and possible diagnostic insight that could be gained through studying bearing noise characteristics were discussed.

  12. Measurement of nuclear reactor noise at low power; Merenje nuklearnog reaktorskog suma na malim snagama

    Energy Technology Data Exchange (ETDEWEB)

    Velickovic, Lj [Boris Kidric Institute of nuclear sciences, Vinca, Belgrade (Yugoslavia)

    1968-07-01

    Theoretical interpretation of reactor noise experiments is based on stochastic model developed and described in this paper. Ratio l/{beta} as well as subcriticality level can be determined bu measuring transfer function. In this paper the ratio l/{beta} was determined directly from auto-correlation functions for different critical configurations of the RB zero power reactor core and not by transfer function. This simplified the procedure significantly. It was found that the 0.5 W power level is most suitable for experimental study of neutron fluctuations. In this case fluctuations are intense compared to noise of the detector and electronic devices used.

  13. [The role of acoustic impedance test in the diagnosis for occupational noise induced deafness].

    Science.gov (United States)

    Chen, H; Xue, L J; Yang, A C; Liang, X Y; Chen, Z Q; Zheng, Q L

    2018-01-20

    Objective: To investigate the characteristics of acoustic impedance test and its diagnostic role for occupational noise induced deafness, in order to provide an objective basis for the differential diagnosis of occupational noise induced deafness. Methods: A retrospective study was conducted to investigate the cases on the diagnosis of occupational noise-induced deafness in Guangdong province hospital for occupational disease prevention and treatment from January 2016 to January 2017. A total of 198 cases (396 ears) were divided into occupation disease group and non occupation disease group based on the diagnostic criteria of occupational noise deafness in 2014 edition, acoustic conductivity test results of two groups were compared including tympanograms types, external auditory canal volume, tympanic pressure, static compliance and slope. Results: In the occupational disease group, 204 ears were found to have 187 ears (91.67%) of type A, which were significantly higher than those in the non occupational disease group 143/192 (74.48%) , the difference was statistically significant (χ(2)=21.038, P occupation disease group in other type were 16/204 (7.84%) , 3/204 (1.47%) , were lower than Ad or As type of occupation disease group (15.63%) , other type (9.38%) , the differences were statistically significant[ (χ(2)=5.834, P Occupation disease group canal volume average (1.68±0.39) ml higher than that of non occupation disease group (1.57 ± 0.47) ml, the difference was statistically significant ( t =2.756, P occupation disease group mean static compliance (1.06±0.82) ml higher than that of non occupation disease group (0.89±0.64) ml. The difference was statistically singificant ( t =2.59, P occupational noise induced deafness, More than 90% of the confirmed cases showed an A-form tympanograms, it is one of the objective examination methods which can be used in the differential diagnosis of pseudo deafness.

  14. Application of the neutron noise analysis technique in nuclear power plants

    International Nuclear Information System (INIS)

    Lescano, Victor H.; Wentzeis, Luis M.

    1999-01-01

    Using the neutron noise analysis in nuclear power plants, and without producing any perturbation in the normal operation of the plant, information of the vibration state of the reactor internals and the behavior of the operating conditions of the reactor primary circuit can be obtained. In Argentina, the neutron noise analysis technique is applied in customary way in the nuclear power plants Atucha I and Embalse. A database was constructed and vibration frequencies corresponding to different reactor internals were characterized. Reactor internals with particular mechanical vibrations have been detected and localized. In the framing of a cooperation project between Argentina and Germany, we participated in the measurements, analysis and modelisation, using the neutron noise technique, in the Obrigheim and Gundremmingen nuclear power plants. In the nuclear power plant Obrigheim (PWR, 350 M We), correlations between the signals measured from self-power neutron detectors and accelerometers located inside the reactor core, were made. In the nuclear power plant Gundremmingen (BWR, 1200 M We) we participated in the study of a particular mechanical vibration detected in one of the instrumentation tube. (author)

  15. The role of Urbis' noise and noise effects maps in local policy

    NARCIS (Netherlands)

    Borst, H.C.

    2001-01-01

    An important aspect of the EU noise policy is mapping of noise and noise effects and the formulation of noise action plans. In the Netherlands, due to the new policy on noise (MIG), the municipalities will be responsible for the formulation of a local noise policy. An instrument for the assessment

  16. ECG signal performance de-noising assessment based on threshold tuning of dual-tree wavelet transform.

    Science.gov (United States)

    El B'charri, Oussama; Latif, Rachid; Elmansouri, Khalifa; Abenaou, Abdenbi; Jenkal, Wissam

    2017-02-07

    Since the electrocardiogram (ECG) signal has a low frequency and a weak amplitude, it is sensitive to miscellaneous mixed noises, which may reduce the diagnostic accuracy and hinder the physician's correct decision on patients. The dual tree wavelet transform (DT-WT) is one of the most recent enhanced versions of discrete wavelet transform. However, threshold tuning on this method for noise removal from ECG signal has not been investigated yet. In this work, we shall provide a comprehensive study on the impact of the choice of threshold algorithm, threshold value, and the appropriate wavelet decomposition level to evaluate the ECG signal de-noising performance. A set of simulations is performed on both synthetic and real ECG signals to achieve the promised results. First, the synthetic ECG signal is used to observe the algorithm response. The evaluation results of synthetic ECG signal corrupted by various types of noise has showed that the modified unified threshold and wavelet hyperbolic threshold de-noising method is better in realistic and colored noises. The tuned threshold is then used on real ECG signals from the MIT-BIH database. The results has shown that the proposed method achieves higher performance than the ordinary dual tree wavelet transform into all kinds of noise removal from ECG signal. The simulation results indicate that the algorithm is robust for all kinds of noises with varying degrees of input noise, providing a high quality clean signal. Moreover, the algorithm is quite simple and can be used in real time ECG monitoring.

  17. Noise in Optical Amplifiers

    DEFF Research Database (Denmark)

    Jeppesen, Palle

    1997-01-01

    Noise in optical amplifiers is discussed on the basis of photons and electromagntic fields. Formulas for quantum noise from spontaneous emission, signal-spontaneous beat noise and spontaneous-spontaneous beat noise are derived.......Noise in optical amplifiers is discussed on the basis of photons and electromagntic fields. Formulas for quantum noise from spontaneous emission, signal-spontaneous beat noise and spontaneous-spontaneous beat noise are derived....

  18. Exploring crosstalk noise generated in the N-port router used in the WDM-based ONoC

    Science.gov (United States)

    Zhang, Zhendong; Xie, Yiyuan; Song, Tingting; He, Chao; Li, Jiachao; Liu, Yong

    2017-07-01

    Compared with optical network-on-chip (ONoC) with single wavelength, ONoC adopting wavelength division multiplexing (WDM) technology possesses a very prominent advantage-higher bandwidth. Therefore, WDM-based ONoC has been considered one of the most promising ways to relieve the rapidly increasing traffic load in communication systems. A WDM-based router, as the core equipment of WDM-based ONoC, is influenced by crosstalk noise, especially the nonlinear crosstalk noise generated by the four-wave mixing effect. Thus, to explore the performance of the N-port nonblocking optical router using WDM, we propose a universal analytic model to analyze the transmission loss, crosstalk noise, optical signal-to-noise ratio (OSNR), and bit error ratio (BER). The research results show that crosstalk noise varies along with signals at different wavelengths in the same channel. For signals with the same wavelength, the noises generated in the different transmission paths are obviously different from each other. For research of transmission loss, OSNR, and BER, similar results can be obtained. Based on the eye diagrams, we can learn that crosstalk noise will cause signal distortion to a certain extent. With this model, capability of this kind of multiport optical router using WDM can be understood conveniently.

  19. Evaluation of noise pollution in urban traffic hubs—Noise maps and measurements

    International Nuclear Information System (INIS)

    Fiedler, Paulo Eduardo Kirrian; Zannin, Paulo Henrique Trombetta

    2015-01-01

    A study was made of some of the main traffic hubs in a Latin American metropolis, in order to determine the presence or absence of noise by means of noise measurements and acoustic mapping. To characterize noise in the evaluated road stretches, 232 measurements were taken at different points. The Predictor software package was used for the noise mapping calculations. Noise sensitive areas, e.g., hospitals, were identified in the evaluated road stretches. Noise maps were calculated for two hospitals, showing the current levels of noise that reach their facades. Hypothetical scenarios were simulated by making changes in the composition of traffic and total number of vehicles, and an assessment was made of the potential influence of these modifications in reducing the noise levels reaching the facades of the buildings in question. The simulations indicated that a 50% reduction in total traffic flow, or a 50% reduction in heavy vehicle traffic flow, would reduce the noise levels by about 3 dB(A). - Highlights: • Evaluation of noise pollution in urban traffic hubs • Street systems • Environmental noise impacts • Noise mapping

  20. Evaluation of noise pollution in urban traffic hubs—Noise maps and measurements

    Energy Technology Data Exchange (ETDEWEB)

    Fiedler, Paulo Eduardo Kirrian; Zannin, Paulo Henrique Trombetta, E-mail: paulo.zannin@pesquisador.cnpq.br

    2015-02-15

    A study was made of some of the main traffic hubs in a Latin American metropolis, in order to determine the presence or absence of noise by means of noise measurements and acoustic mapping. To characterize noise in the evaluated road stretches, 232 measurements were taken at different points. The Predictor software package was used for the noise mapping calculations. Noise sensitive areas, e.g., hospitals, were identified in the evaluated road stretches. Noise maps were calculated for two hospitals, showing the current levels of noise that reach their facades. Hypothetical scenarios were simulated by making changes in the composition of traffic and total number of vehicles, and an assessment was made of the potential influence of these modifications in reducing the noise levels reaching the facades of the buildings in question. The simulations indicated that a 50% reduction in total traffic flow, or a 50% reduction in heavy vehicle traffic flow, would reduce the noise levels by about 3 dB(A). - Highlights: • Evaluation of noise pollution in urban traffic hubs • Street systems • Environmental noise impacts • Noise mapping.

  1. Temporal compounding: a novel implementation and its impact on quality and diagnostic value in echocardiography.

    Science.gov (United States)

    Perperidis, Antonios; Cusack, David; White, Audrey; McDicken, Norman; MacGillivray, Tom; Anderson, Tom

    2015-06-01

    Temporal compounding can be used to suppress acoustic noise in transthoracic cardiac ultrasound by spatially averaging partially decorrelated images acquired over consecutive cardiac cycles. However, the reliable spatial and temporal alignment of the corresponding frames in consecutive cardiac cycles is vital for effective implementation of temporal compounding. This study introduces a novel, efficient, accurate and robust technique for the spatiotemporal alignment of consecutive cardiac cycles with variable temporal characteristics. Furthermore, optimal acquisition parameters, such as the number of consecutive cardiac cycles used, are derived. The effect of the proposed implementation of temporal compounding on cardiac ultrasound images is quantitatively assessed (32 clinical data sets providing a representative range of image qualities and diagnostic values) using measures such as tissue signal-to-noise ratio, chamber signal-to-noise ratio, tissue/chamber contrast and detectability index, as well as a range of clinical measurements, such as chamber diameter and wall thickness, performed during routine echocardiographic examinations. Temporal compounding (as implemented) consistently improved the image quality and diagnostic value of the processed images, when compared with the original data by: (i) increasing tissue and cavity signal-to-noise ratios as well as tissue/cavity detectability index, (ii) improving the corresponding clinical measurement repeatability and inter-operator measurement agreement, while (iii) reducing the number of omitted measurements caused by data corruption. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  2. Use and evaluation of molecular diagnostics for pneumonia etiology studies

    NARCIS (Netherlands)

    Bhat, Niranjan; O'Brien, Katherine L.; Karron, Ruth A.; Driscoll, Amanda J.; Murdoch, David R.; Black, Robert E.; Bhutta, Zulfiqar A.; Campbell, Harry; Cherian, Thomas; Crook, Derrick W.; de Jong, Menno D.; Dowell, Scott F.; Graham, Stephen M.; Klugman, Keith P.; Lanata, Claudio F.; Madhi, Shabir A.; Martin, Paul; Nataro, James P.; Piazza, Franco M.; Qazi, Shamim A.; Zar, Heather J.

    2012-01-01

    Comprehensive microbiological testing will be a core function of the Pneumonia Etiology Research for Child Health (PERCH) project. The development stage of PERCH provided the time and resources necessary for us to conduct a comprehensive review of the current state of respiratory diagnostics. These

  3. A report on the second specialists' meeting on reactor noise (SMORN II) Gatlinburg, Tennessee, September 19th-23rd 1977

    International Nuclear Information System (INIS)

    Greef, C.P.

    1978-03-01

    The current state of power reactor noise analysis as presented at the Second Specialists' Meeting on Reactor Noise (SMORN II) is reviewed. Practical successes include the analysis of PWR core support barrel motions and BWR instrument tube vibrations, leading to better understanding of the Physical processes involved. Future applications to LMFBRs are being actively pursued, but more information is required, notably on background noise sources in operating reactors. Theoretical understanding is improving in a number of specific areas, but general fundamental progress is hampered by the multiplicity of potential noise sources in a reactor. Past attempts to automate noise analysis so that simplified information may be presented to the reactor operator have not been totally successful. This has resulted from an over-hasty application of the techniques before all of the factors involved in physical phenomena were fully appreciated. (author)

  4. Adaptive EMG noise reduction in ECG signals using noise level approximation

    Science.gov (United States)

    Marouf, Mohamed; Saranovac, Lazar

    2017-12-01

    In this paper the usage of noise level approximation for adaptive Electromyogram (EMG) noise reduction in the Electrocardiogram (ECG) signals is introduced. To achieve the adequate adaptiveness, a translation-invariant noise level approximation is employed. The approximation is done in the form of a guiding signal extracted as an estimation of the signal quality vs. EMG noise. The noise reduction framework is based on a bank of low pass filters. So, the adaptive noise reduction is achieved by selecting the appropriate filter with respect to the guiding signal aiming to obtain the best trade-off between the signal distortion caused by filtering and the signal readability. For the evaluation purposes; both real EMG and artificial noises are used. The tested ECG signals are from the MIT-BIH Arrhythmia Database Directory, while both real and artificial records of EMG noise are added and used in the evaluation process. Firstly, comparison with state of the art methods is conducted to verify the performance of the proposed approach in terms of noise cancellation while preserving the QRS complex waves. Additionally, the signal to noise ratio improvement after the adaptive noise reduction is computed and presented for the proposed method. Finally, the impact of adaptive noise reduction method on QRS complexes detection was studied. The tested signals are delineated using a state of the art method, and the QRS detection improvement for different SNR is presented.

  5. The Assessment of Noise Exposure and Noise Annoyance at a Petrochemical Company

    Directory of Open Access Journals (Sweden)

    S. Farhang Dehghan

    2013-12-01

    .Conclusion: Based on the obtained results of investigating the noise level (objective exposure as well as the noise annoyance (subjective exposure at the studied company, it is necessary to adopt the management –technical noise reduction measures at manufacturing sectors as the personal noise exposure and environmental noise exposure and also noise personal exposure of administrative staff can be decreased.

  6. Noise pollution resources compendium

    Science.gov (United States)

    1973-01-01

    Abstracts of reports concerning noise pollution are presented. The abstracts are grouped in the following areas of activity: (1) sources of noise, (2) noise detection and measurement, (3) noise abatement and control, (4) physical effects of noise and (5) social effects of noise.

  7. Solar noise storms

    CERN Document Server

    Elgaroy, E O

    2013-01-01

    Solar Noise Storms examines the properties and features of solar noise storm phenomenon. The book also presents some theories that can be used to gain a better understanding of the phenomenon. The coverage of the text includes topics that cover the features and behavior of noise storms, such as the observable features of noise storms; the relationship between noise storms and the observable features on the sun; and ordered behavior of storm bursts in the time-frequency plane. The book also covers the spectrum, polarization, and directivity of noise storms. The text will be of great use to astr

  8. Low noise constant current source for bias dependent noise measurements

    International Nuclear Information System (INIS)

    Talukdar, D.; Bose, Suvendu; Bardhan, K. K.; Chakraborty, R. K.

    2011-01-01

    A low noise constant current source used for measuring the 1/f noise in disordered systems in ohmic as well as nonohmic regime is described. The source can supply low noise constant current starting from as low as 1 μA to a few tens of milliampere with a high voltage compliance limit of around 20 V. The constant current source has several stages, which can work in a standalone manner or together to supply the desired value of load current. The noise contributed by the current source is very low in the entire current range. The fabrication of a low noise voltage preamplifier modified for bias dependent noise measurements and based on the existing design available in the MAT04 data sheet is also described.

  9. Proceedings of the 2009 spring noise conference : noise awareness : supporting sound partnerships

    International Nuclear Information System (INIS)

    2009-01-01

    This conference provided a forum for industry, government, public, academics and acoustical professionals to discuss innovations in environmental and occupational noise identification, measurement, regulation and control. In addition to raising awareness about expanding noise issues, the conference objectives were to promote responsible industrial development and to identify strategies for reducing workplace noise exposure. The papers focused on research, developments and case studies and highlighted current issues and advancements in technology and software. Speakers from around the world discussed topics ranging from occupational noise issues to low frequency. The 8 sessions were entitled: (1) plenary session, (2) architecture, community planning and public health: effects of noise and noise control, (3) modeling, measurement and technology; (4) noise awareness and education: public, occupational and industrial, (5) regulations and economics: bylaws, legislation and the economics of noise control; (6) student papers, (7) vibration, industrial noise, transportation noise and occupational noise control, and (8) lunch speakers. The conference featured 46 presentations, of which 19 have been catalogued separately for inclusion in this database. refs., tabs., figs.

  10. Noise in strong laser-atom interactions: Phase telegraph noise

    International Nuclear Information System (INIS)

    Eberly, J.H.; Wodkiewicz, K.; Shore, B.W.

    1984-01-01

    We discuss strong laser-atom interactions that are subjected to jump-type (random telegraph) random-phase noise. Physically, the jumps may arise from laser fluctuations, from collisions of various kinds, or from other external forces. Our discussion is carried out in two stages. First, direct and partially heuristic calculations determine the laser spectrum and also give a third-order differential equation for the average inversion of a two-level atom on resonance. At this stage a number of general features of the interaction are able to be studied easily. The optical analog of motional narrowing, for example, is clearly predicted. Second, we show that the theory of generalized Poisson processes allows laser-atom interactions in the presence of random telegraph noise of all kinds (not only phase noise) to be treated systematically, by means of a master equation first used in the context of quantum optics by Burshtein. We use the Burshtein equation to obtain an exact expression for the two-level atom's steady-state resonance fluorescence spectrum, when the exciting laser exhibits phase telegraph noise. Some comparisons are made with results obtained from other noise models. Detailed treatments of the effects ofmly jumps, or as a model of finite laser bandwidth effects, in which the laser frequency exhibits random jumps. We show that these two types of frequency noise can be distinguished in light-scattering spectra. We also discuss examples which demonstrate both temporal and spectral motional narrowing, nonexponential correlations, and non-Lorentzian spectra. Its exact solubility in finite terms makes the frequency-telegraph noise model an attractive alternative to the white-noise Ornstein-Uhlenbeck frequency noise model which has been previously applied to laser-atom interactions

  11. Measurement of reactivity temperature coefficient by noise method in a power reactor

    International Nuclear Information System (INIS)

    Aguilar, O.

    1986-07-01

    The temperature reactivity coefficient was estimated on the basis of noise measurements performed in a PWR. The magnitude of the coefficient was evaluated by relating the values of the APSD and CPSD between ex-core neutron detector signals and fuel assembly outlet thermocouple in the low frequency range. Comparison with δρ/δT measurements performed in PWR by standard methods supports the validity of the results. (author)

  12. Background Noise Reduction Using Adaptive Noise Cancellation Determined by the Cross-Correlation

    Science.gov (United States)

    Spalt, Taylor B.; Brooks, Thomas F.; Fuller, Christopher R.

    2012-01-01

    Background noise due to flow in wind tunnels contaminates desired data by decreasing the Signal-to-Noise Ratio. The use of Adaptive Noise Cancellation to remove background noise at measurement microphones is compromised when the reference sensor measures both background and desired noise. The technique proposed modifies the classical processing configuration based on the cross-correlation between the reference and primary microphone. Background noise attenuation is achieved using a cross-correlation sample width that encompasses only the background noise and a matched delay for the adaptive processing. A present limitation of the method is that a minimum time delay between the background noise and desired signal must exist in order for the correlated parts of the desired signal to be separated from the background noise in the crosscorrelation. A simulation yields primary signal recovery which can be predicted from the coherence of the background noise between the channels. Results are compared with two existing methods.

  13. Classical noise, quantum noise and secure communication

    International Nuclear Information System (INIS)

    Tannous, C; Langlois, J

    2016-01-01

    Secure communication based on message encryption might be performed by combining the message with controlled noise (called pseudo-noise) as performed in spread-spectrum communication used presently in Wi-Fi and smartphone telecommunication systems. Quantum communication based on entanglement is another route for securing communications as demonstrated by several important experiments described in this work. The central role played by the photon in unifying the description of classical and quantum noise as major ingredients of secure communication systems is highlighted and described on the basis of the classical and quantum fluctuation dissipation theorems. (review)

  14. Application of diagnostic system for diesel engines in nuclear power plant

    International Nuclear Information System (INIS)

    Yoshinaga, Takeshi

    2004-01-01

    The diagnostic system for diesel engines makes a diagnosis of secular change and abnormal indications of diesel engines (DG) by combination of characteristic analysis of engine, lubricating oil, fuel oil, and cooling water. The principles of diagnostic system for DG, results of confirmation of the efficiency and the maintenance plan for DG in the Japan Atomic Power Company are described. DG in the company is classified to a safety device in order to supply the power source to the Emergency Core Cooling System etc., when the power source in the plant is lost, for example, at lightning struck. Characteristics of DG, outline of the diagnostic system for DG, diagnostic technologies such as engine signature analysis, chemical analysis of samples, temperature measurement, degradation mode of DG, and training in the company are stated. (S.Y.)

  15. Frame-Transfer Gating Raman Spectroscopy for Time-Resolved Multiscalar Combustion Diagnostics

    Science.gov (United States)

    Nguyen, Quang-Viet; Fischer, David G.; Kojima, Jun

    2011-01-01

    Accurate experimental measurement of spatially and temporally resolved variations in chemical composition (species concentrations) and temperature in turbulent flames is vital for characterizing the complex phenomena occurring in most practical combustion systems. These diagnostic measurements are called multiscalar because they are capable of acquiring multiple scalar quantities simultaneously. Multiscalar diagnostics also play a critical role in the area of computational code validation. In order to improve the design of combustion devices, computational codes for modeling turbulent combustion are often used to speed up and optimize the development process. The experimental validation of these codes is a critical step in accepting their predictions for engine performance in the absence of cost-prohibitive testing. One of the most critical aspects of setting up a time-resolved stimulated Raman scattering (SRS) diagnostic system is the temporal optical gating scheme. A short optical gate is necessary in order for weak SRS signals to be detected with a good signal- to-noise ratio (SNR) in the presence of strong background optical emissions. This time-synchronized optical gating is a classical problem even to other spectroscopic techniques such as laser-induced fluorescence (LIF) or laser-induced breakdown spectroscopy (LIBS). Traditionally, experimenters have had basically two options for gating: (1) an electronic means of gating using an image intensifier before the charge-coupled-device (CCD), or (2) a mechanical optical shutter (a rotary chopper/mechanical shutter combination). A new diagnostic technology has been developed at the NASA Glenn Research Center that utilizes a frame-transfer CCD sensor, in conjunction with a pulsed laser and multiplex optical fiber collection, to realize time-resolved Raman spectroscopy of turbulent flames that is free from optical background noise (interference). The technology permits not only shorter temporal optical gating (down

  16. Radiation dose reduction through combining positron emission tomography/computed tomography (PET/CT) and diagnostic CT in children and young adults with lymphoma.

    Science.gov (United States)

    Qi, Zhihua; Gates, Erica L; O'Brien, Maureen M; Trout, Andrew T

    2018-02-01

    Both [F-18]2-fluoro-2-deoxyglucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT) and diagnostic CT are at times required for lymphoma staging. This means some body segments are exposed twice to X-rays for generation of CT data (diagnostic CT + localization CT). To describe a combined PET/diagnostic CT approach that modulates CT tube current along the z-axis, providing diagnostic CT of some body segments and localization CT of the remaining body segments, thereby reducing patient radiation dose. We retrospectively compared total patient radiation dose between combined PET/diagnostic CT and separately acquired PET/CT and diagnostic CT exams. When available, we calculated effective doses for both approaches in the same patient; otherwise, we used data from patients of similar size. To confirm image quality, we compared image noise (Hounsfield unit [HU] standard deviation) as measured in the liver on both combined and separately acquired diagnostic CT images. We used t-tests for dose comparisons and two one-sided tests for image-quality equivalence testing. Mean total effective dose for the CT component of the combined and separately acquired diagnostic CT exams were 6.20±2.69 and 8.17±2.61 mSv, respectively (PCT effective dose. Image noise was not statistically significantly different between approaches (12.2±1.8 HU vs. 11.7±1.5 HU for the combined and separately acquired diagnostic CT images, respectively). A combined PET/diagnostic CT approach as described offers dose savings at similar image quality for children and young adults with lymphoma who have indications for both PET and diagnostic CT examinations.

  17. THE EFFECT OF LINE-OF-SIGHT TEMPERATURE VARIATION AND NOISE ON DUST CONTINUUM OBSERVATIONS

    International Nuclear Information System (INIS)

    Shetty, Rahul; Kauffmann, Jens; Goodman, Alyssa A.; Ercolano, Barbara; Schnee, Scott

    2009-01-01

    We investigate the effect of line-of-sight temperature variations and noise on two commonly used methods to determine dust properties from dust-continuum observations of dense cores. One method employs a direct fit to a modified blackbody spectral energy distribution (SED); the other involves a comparison of flux ratios to an analytical prediction. Fitting fluxes near the SED peak produces inaccurate temperature and dust spectral index estimates due to the line-of-sight temperature (and density) variations. Longer wavelength fluxes in the Rayleigh-Jeans part of the spectrum (∼> 600 μm for typical cores) may more accurately recover the spectral index, but both methods are very sensitive to noise. The temperature estimate approaches the density-weighted temperature, or 'column temperature', of the source as short wavelength fluxes are excluded. An inverse temperature-spectral index correlation naturally results from SED fitting, due to the inaccurate isothermal assumption, as well as noise uncertainties. We show that above some 'threshold' temperature, the temperatures estimated through the flux ratio method can be highly inaccurate. In general, observations with widely separated wavelengths, and including shorter wavelengths, result in higher threshold temperatures; such observations thus allow for more accurate temperature estimates of sources with temperatures less than the threshold temperature. When only three fluxes are available, a constrained fit, where the spectral index is fixed, produces less scatter in the temperature estimate when compared to the estimate from the flux ratio method.

  18. Image noise reduction technology reduces radiation in a radial-first cardiac catheterization laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Gunja, Ateka; Pandey, Yagya [Department of Veterans Affairs, Jesse Brown VA Medical Center, Chicago, IL (United States); Division of Cardiology, Department of Medicine, University of Illinois at Chicago, Chicago, IL (United States); Xie, Hui [Division of Epidemiology and Biostatistics, University of Illinois at Chicago, Chicago, IL (United States); Faculty of Health Sciences, Simon Fraser University, Burnaby, BC (Canada); Wolska, Beata M. [Department of Physiology and Biophysics, Center for Cardiovascular Research, University of Illinois at Chicago, Chicago, IL (United States); Shroff, Adhir R.; Ardati, Amer K. [Department of Veterans Affairs, Jesse Brown VA Medical Center, Chicago, IL (United States); Division of Cardiology, Department of Medicine, University of Illinois at Chicago, Chicago, IL (United States); Vidovich, Mladen I., E-mail: miv@uic.edu [Department of Veterans Affairs, Jesse Brown VA Medical Center, Chicago, IL (United States); Division of Cardiology, Department of Medicine, University of Illinois at Chicago, Chicago, IL (United States)

    2017-04-15

    Background: Transradial coronary angiography (TRA) has been associated with increased radiation doses. We hypothesized that contemporary image noise reduction technology would reduce radiation doses in the cardiac catheterization laboratory in a typical clinical setting. Methods and results: We performed a single-center, retrospective analysis of 400 consecutive patients who underwent diagnostic and interventional cardiac catheterizations in a predominantly TRA laboratory with traditional fluoroscopy (N = 200) and a new image noise reduction fluoroscopy system (N = 200). The primary endpoint was radiation dose (mGy cm{sup 2}). Secondary endpoints were contrast dose, fluoroscopy times, number of cineangiograms, and radiation dose by operator between the two study periods. Radiation was reduced by 44.7% between the old and new cardiac catheterization laboratory (75.8 mGy cm{sup 2} ± 74.0 vs. 41.9 mGy cm{sup 2} ± 40.7, p < 0.0001). Radiation was reduced for both diagnostic procedures (45.9%, p < 0.0001) and interventional procedures (37.7%, p < 0.0001). There was no statistically significant difference in radiation dose between individual operators (p = 0.84). In multivariate analysis, radiation dose remained significantly decreased with the use of the new system (p < 0.0001) and was associated with weight (p < 0.0001), previous coronary artery bypass grafting (p < 0.0007) and greater than 3 stents used (p < 0.0004). TRA was used in 90% of all cases in both periods. Compared with a transfemoral approach (TFA), TRA was not associated with higher radiation doses (p = 0.20). Conclusions: Image noise reduction technology significantly reduces radiation dose in a contemporary radial-first cardiac catheterization clinical practice. - Highlights: • Radial arterial access has been associated with higher doses compared to femoral access. • In a radial-first cardiac catheterization laboratory (90% radial) we examined radiation doses reduction with a contemporary image-noise

  19. Image noise reduction technology reduces radiation in a radial-first cardiac catheterization laboratory

    International Nuclear Information System (INIS)

    Gunja, Ateka; Pandey, Yagya; Xie, Hui; Wolska, Beata M.; Shroff, Adhir R.; Ardati, Amer K.; Vidovich, Mladen I.

    2017-01-01

    Background: Transradial coronary angiography (TRA) has been associated with increased radiation doses. We hypothesized that contemporary image noise reduction technology would reduce radiation doses in the cardiac catheterization laboratory in a typical clinical setting. Methods and results: We performed a single-center, retrospective analysis of 400 consecutive patients who underwent diagnostic and interventional cardiac catheterizations in a predominantly TRA laboratory with traditional fluoroscopy (N = 200) and a new image noise reduction fluoroscopy system (N = 200). The primary endpoint was radiation dose (mGy cm"2). Secondary endpoints were contrast dose, fluoroscopy times, number of cineangiograms, and radiation dose by operator between the two study periods. Radiation was reduced by 44.7% between the old and new cardiac catheterization laboratory (75.8 mGy cm"2 ± 74.0 vs. 41.9 mGy cm"2 ± 40.7, p < 0.0001). Radiation was reduced for both diagnostic procedures (45.9%, p < 0.0001) and interventional procedures (37.7%, p < 0.0001). There was no statistically significant difference in radiation dose between individual operators (p = 0.84). In multivariate analysis, radiation dose remained significantly decreased with the use of the new system (p < 0.0001) and was associated with weight (p < 0.0001), previous coronary artery bypass grafting (p < 0.0007) and greater than 3 stents used (p < 0.0004). TRA was used in 90% of all cases in both periods. Compared with a transfemoral approach (TFA), TRA was not associated with higher radiation doses (p = 0.20). Conclusions: Image noise reduction technology significantly reduces radiation dose in a contemporary radial-first cardiac catheterization clinical practice. - Highlights: • Radial arterial access has been associated with higher doses compared to femoral access. • In a radial-first cardiac catheterization laboratory (90% radial) we examined radiation doses reduction with a contemporary image-noise compared to

  20. Two novel plasma diagnostic tools: fiber sensors and phase conjugation

    International Nuclear Information System (INIS)

    Jahoda, F.C.

    1985-01-01

    A rapidly developing technology (single-mode optical fiber sensors) and recent fundamental research in nonlinear optics (phase conjugation) both offer opportunities for novel plasma diagnostics. Single-mode fiber sensors can replace electrical wire probes for current and magnetic field measurements with advantages in voltage insulation requirements, electromagnetic noise immunity, much greater bandwidth, and some configuration flexibility. Faraday rotation measurements through fibers wound on the ZT-40M RFP have demonstrated quantitative results, but competing linear birefringence effects still hinder independent interpretation. Twisted fiber may solve this problem. Optical phase conjugation (in which a phase reversed copy of a laser beam is generated) allows real time distortion corrections in laser diagnostics. Self-pumped phase conjugation in BaTiO 3 improves the quality of phase conjugation imagery and greatly simplifies experimentation directed toward plasma diagnostics. Our initial applications are a) time-differential refractometry with high spatial resolution and b) intracavity absorption Zeeman spectroscopy

  1. Diagnostic System of Drill Condition in Laminated Chipboard Drilling Process

    Directory of Open Access Journals (Sweden)

    Swiderski Bartosz

    2017-01-01

    Full Text Available The paper presents an on-line automatic system for recognition of the drill condition in a laminated chipboard drilling process. Two states of the drill are considered: the sharp enough (still able to drill holes acceptable for processing quality and worn out (excessive drill wear, not satisfactory from the quality point of view of the process. The automatic system requires defining the diagnostic features, which are used as the input attributes to the classifier. The features have been generated from 5 registered signals: feed force, cutting torque, noise, vibration and acoustic emission. The statistical parameters defined on the basis of the auto regression model of these signals have been used as the diagnostic features. The sequential step-wise feature selection is applied for choosing the most discriminative set of features. The final step of recognition is done by support vector machine classifier working in leave one out mode. The results of numerical experiments have confirmed good quality of the proposed diagnostic system.

  2. Innovative diagnostics for ITER physics addressed in JET

    Energy Technology Data Exchange (ETDEWEB)

    Murari, A; Alfier, A; Pasqualotto, R [Associazione EURATOM-ENEA per la Fusione, Consorzio RFX, 4-35127 Padova (Italy); Edlington, T; Andrew, Y; Arnoux, G; Beurskens, M; Coad, P; Kempenaars, M; Kiptily, V; Meigs, A [Euratom/UKAEA Fusion Association, Culham Science Centre, Abingdon, Oxon, OX14 3DB (United Kingdom); Alonso, A; Hidalgo, C [Asociacion EURATOM-CIEMAT para Fusion, CIEMAT, Madrid (Spain); Crombe, C [Department of Applied Physics, Ghent University, Rozier 44, 900 Gent (Belgium); Gauthier, E; Giroud, C; Hong, S; Loarer, T [Association EURATOM-CEA, CEA Cadarache, 13108 Saint-Paul-lez-Durance (France); Tala, T [Association EURATOM-Tekes, VTT, PO Box 1000, FIN-02044 VTT (Finland)

    2008-12-15

    In recent years, JET diagnostic capability has been significantly improved to widen the range of physical phenomena that can be studied and thus contribute to the understanding of some ITER relevant issues. The most significant results reported in this paper refer to the plasma wall interactions, the interplay between core and edge physics and fast particles. A synergy between new infrared cameras, visible cameras and spectroscopy diagnostics has allowed investigating a series of new aspects of the plasma wall interactions. The power loads on the plasma facing components of JET main chambers have been assessed at steady state and during transient events like ELMs and disruptions. Evidence of filaments in the edge region of the plasma has been collected with a new fast visible camera and high resolution Thomson scattering. The physics of detached plasmas and some new aspects of dust formation have also been devoted particular attention. The influence of the edge plasma on the core has been investigated with upgraded active spectroscopy, providing new information on momentum transport and the effects of impurity injection on ELMs and ITBs and their interdependence. Given the fact that JET is the only machine with a plasma volume big enough to confine the alphas, a coherent programme of diagnostic developments for the energetic particles has been undertaken. With upgraded {gamma}-ray spectroscopy and a new scintillator probe, it is now possible to study both the redistribution and the losses of the fast particles in various plasma conditions.

  3. Modelling of magnetostriction of transformer magnetic core for vibration analysis

    Science.gov (United States)

    Marks, Janis; Vitolina, Sandra

    2017-12-01

    Magnetostriction is a phenomenon occurring in transformer core in normal operation mode. Yet in time, it can cause the delamination of magnetic core resulting in higher level of vibrations that are measured on the surface of transformer tank during diagnostic tests. The aim of this paper is to create a model for evaluating elastic deformations in magnetic core that can be used for power transformers with intensive vibrations in order to eliminate magnetostriction as a their cause. Description of the developed model in Matlab and COMSOL software is provided including restrictions concerning geometry and properties of materials, and the results of performed research on magnetic core anisotropy are provided. As a case study modelling of magnetostriction for 5-legged 200 MVA power transformer with the rated voltage of 13.8/137kV is conducted, based on which comparative analysis of vibration levels and elastic deformations is performed.

  4. Modelling of magnetostriction of transformer magnetic core for vibration analysis

    Directory of Open Access Journals (Sweden)

    Marks Janis

    2017-12-01

    Full Text Available Magnetostriction is a phenomenon occurring in transformer core in normal operation mode. Yet in time, it can cause the delamination of magnetic core resulting in higher level of vibrations that are measured on the surface of transformer tank during diagnostic tests. The aim of this paper is to create a model for evaluating elastic deformations in magnetic core that can be used for power transformers with intensive vibrations in order to eliminate magnetostriction as a their cause. Description of the developed model in Matlab and COMSOL software is provided including restrictions concerning geometry and properties of materials, and the results of performed research on magnetic core anisotropy are provided. As a case study modelling of magnetostriction for 5-legged 200 MVA power transformer with the rated voltage of 13.8/137kV is conducted, based on which comparative analysis of vibration levels and elastic deformations is performed.

  5. Definition of 1992 Technology Aircraft Noise Levels and the Methodology for Assessing Airplane Noise Impact of Component Noise Reduction Concepts

    Science.gov (United States)

    Kumasaka, Henry A.; Martinez, Michael M.; Weir, Donald S.

    1996-01-01

    This report describes the methodology for assessing the impact of component noise reduction on total airplane system noise. The methodology is intended to be applied to the results of individual study elements of the NASA-Advanced Subsonic Technology (AST) Noise Reduction Program, which will address the development of noise reduction concepts for specific components. Program progress will be assessed in terms of noise reduction achieved, relative to baseline levels representative of 1992 technology airplane/engine design and performance. In this report, the 1992 technology reference levels are defined for assessment models based on four airplane sizes - an average business jet and three commercial transports: a small twin, a medium sized twin, and a large quad. Study results indicate that component changes defined as program final goals for nacelle treatment and engine/airframe source noise reduction would achieve from 6-7 EPNdB reduction of total airplane noise at FAR 36 Stage 3 noise certification conditions for all of the airplane noise assessment models.

  6. Rating environmental noise on the basis of noise maps

    NARCIS (Netherlands)

    Miedema, H.M.E.; Borst, H.C.

    2006-01-01

    A system that rates noise on the basis of noise maps has been developed which is based on empirical exposure-response relationships, so that effects in the community will be lower if the system gives a better rating. It is consistent with noise metrics and effect endpoint chosen in the EU, i.e., it

  7. Yesterday's noise - today's signal

    International Nuclear Information System (INIS)

    Serdula, K.J.

    1978-01-01

    Plant performance can be improved by noise analysis. This paper describes noise characteristics, imposed noise and response functions, a case history of cost benefits derived from application of noise analysis techniques, areas for application of noise analysis techniques with special reference to the Gentilly-1 nuclear generating station, and the validity of noise measurement results. (E.C.B.)

  8. Noise suppression in duct

    International Nuclear Information System (INIS)

    Ahmed, A.; Barfeh, M.A.G.

    2001-01-01

    In air-conditioning system the noise generated by supply fan is carried by conditioned air through the ductwork. The noise created in ductwork run may be transmission, regenerative and ductborne. Transmission noise is fan noise, regenerative noise is due to turbulence in flow and ductborne noise is the noise radiating from duct to surroundings. Some noise is attenuated in ducts also but if noise level is high then it needs to be attenuated. A simple mitre bend can attenuate-noise. This principle is extended to V and M-shape ducts with inside lining of fibreglass, which gave maximum attenuation of 77 dB and 62 dB respectively corresponding to 8 kHz frequency as compared to mitre, bend giving maximum 18 dB attenuation. Sound level meter measured sound levels with octave band filter and tests were conducted in anechoic room. A V-shape attenuator can be used at fan outlet and high frequency noise can be minimized greatly. (author)

  9. The neutron imaging diagnostic at NIF (invited).

    Science.gov (United States)

    Merrill, F E; Bower, D; Buckles, R; Clark, D D; Danly, C R; Drury, O B; Dzenitis, J M; Fatherley, V E; Fittinghoff, D N; Gallegos, R; Grim, G P; Guler, N; Loomis, E N; Lutz, S; Malone, R M; Martinson, D D; Mares, D; Morley, D J; Morgan, G L; Oertel, J A; Tregillis, I L; Volegov, P L; Weiss, P B; Wilde, C H; Wilson, D C

    2012-10-01

    A neutron imaging diagnostic has recently been commissioned at the National Ignition Facility (NIF). This new system is an important diagnostic tool for inertial fusion studies at the NIF for measuring the size and shape of the burning DT plasma during the ignition stage of Inertial Confinement Fusion (ICF) implosions. The imaging technique utilizes a pinhole neutron aperture, placed between the neutron source and a neutron detector. The detection system measures the two dimensional distribution of neutrons passing through the pinhole. This diagnostic has been designed to collect two images at two times. The long flight path for this diagnostic, 28 m, results in a chromatic separation of the neutrons, allowing the independently timed images to measure the source distribution for two neutron energies. Typically the first image measures the distribution of the 14 MeV neutrons and the second image of the 6-12 MeV neutrons. The combination of these two images has provided data on the size and shape of the burning plasma within the compressed capsule, as well as a measure of the quantity and spatial distribution of the cold fuel surrounding this core.

  10. The neutron imaging diagnostic at NIF (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Merrill, F. E.; Clark, D. D.; Danly, C. R.; Drury, O. B.; Fatherley, V. E.; Gallegos, R.; Grim, G. P.; Guler, N.; Loomis, E. N.; Martinson, D. D.; Mares, D.; Morley, D. J.; Morgan, G. L.; Oertel, J. A.; Tregillis, I. L.; Volegov, P. L.; Wilde, C. H.; Wilson, D. C. [Los Alamos National Laboratory, Los Alamos, New Mexico 87544 (United States); Bower, D.; Dzenitis, J. M. [Livermore National Laboratory, Livermore, California 94550 (United States); and others

    2012-10-15

    A neutron imaging diagnostic has recently been commissioned at the National Ignition Facility (NIF). This new system is an important diagnostic tool for inertial fusion studies at the NIF for measuring the size and shape of the burning DT plasma during the ignition stage of Inertial Confinement Fusion (ICF) implosions. The imaging technique utilizes a pinhole neutron aperture, placed between the neutron source and a neutron detector. The detection system measures the two dimensional distribution of neutrons passing through the pinhole. This diagnostic has been designed to collect two images at two times. The long flight path for this diagnostic, 28 m, results in a chromatic separation of the neutrons, allowing the independently timed images to measure the source distribution for two neutron energies. Typically the first image measures the distribution of the 14 MeV neutrons and the second image of the 6-12 MeV neutrons. The combination of these two images has provided data on the size and shape of the burning plasma within the compressed capsule, as well as a measure of the quantity and spatial distribution of the cold fuel surrounding this core.

  11. Effect of a television digital noise reduction device on fluoroscopic image quality and dose rate

    International Nuclear Information System (INIS)

    Jaffe, C.C.; Orphanoudakis, S.C.; Ablow, R.C.

    1982-01-01

    In conventional fluoroscopy, the current, and therefore the dose rate, is usually determined by the level at which the radiologist visualizes a just tolerable amount of photon ''mottle'' on the video monitor. In this study, digital processing of the analogue video image reduced noise and generated a television image at half the usual exposure rate. The technique uses frame delay to compare an incoming frame with the preceding output frame. A first-order recursive filter implemented under a motion-detection scheme operates on the image of a point-by-point basis. This effective motion detection algorithm permits noise suppression without creating noticeable lag in moving structures. Eight radiologists evaluated images of vesicoureteral reflux in the pig for noise, contrast, resolution, and general image quality on a five-point preferential scale. They rated the digitally processed fluoroscopy images equivalent in diagnostic value to unprocessed images

  12. Wide-band CMOS low-noise amplifier exploiting thermal noise canceling

    OpenAIRE

    Bruccoleri, F.; Klumperink, Eric A.M.; Nauta, Bram

    2004-01-01

    Known elementary wide-band amplifiers suffer from a fundamental tradeoff between noise figure (NF) and source impedance matching, which limits the NF to values typically above 3 dB. Global negative feedback can be used to break this tradeoff, however, at the price of potential instability. In contrast, this paper presents a feedforward noise-canceling technique, which allows for simultaneous noise and impedance matching, while canceling the noise and distortion contributions of the matching d...

  13. Application of noise analysis on the operation of the RSG-GAS reactor

    International Nuclear Information System (INIS)

    Surian P, Tukiran S

    1999-01-01

    The RSG-GAS reactor has been operating for radioisotope production and experiments so that it is necessary to perform analysis of the reactor operation. analysis was done based on reactor noise experiment. Neutron noise at low and high power of the RSG-GAS has been analyzed using time and frequency domain with aim to determine the safety of reactor operation. The safety of reactor operation based on two parameters as, prompt neutron decay constant and decay ratio. The parameters are useful for reactor operation, so it is necessary to determine accurately. For determining prompt neutron decay constant, neutron density in the core of reactor which operated at 10 k W, was collected by using Fission Chamber detectors (FC). Based on power spectral density (PSD) was achieved break frequency about 23 Hz, so that the prompt neutron decay constant is about 151 sec -1 . While at at high power 20 MW, neutron density was collected by using Compensated Ionization Chamber (CIC) detector. The result at high power showed that there is reactivity effect in the core because of fluctuation in temperature and density of the coolant, and the decay ratio of 0.20, showed that the reactor is still operation in stable

  14. Rotor Wake/Stator Interaction Noise Prediction Code Technical Documentation and User's Manual

    Science.gov (United States)

    Topol, David A.; Mathews, Douglas C.

    2010-01-01

    This report documents the improvements and enhancements made by Pratt & Whitney to two NASA programs which together will calculate noise from a rotor wake/stator interaction. The code is a combination of subroutines from two NASA programs with many new features added by Pratt & Whitney. To do a calculation V072 first uses a semi-empirical wake prediction to calculate the rotor wake characteristics at the stator leading edge. Results from the wake model are then automatically input into a rotor wake/stator interaction analytical noise prediction routine which calculates inlet aft sound power levels for the blade-passage-frequency tones and their harmonics, along with the complex radial mode amplitudes. The code allows for a noise calculation to be performed for a compressor rotor wake/stator interaction, a fan wake/FEGV interaction, or a fan wake/core stator interaction. This report is split into two parts, the first part discusses the technical documentation of the program as improved by Pratt & Whitney. The second part is a user's manual which describes how input files are created and how the code is run.

  15. Automated tru-cut imaging-guided core needle biopsy of canine ...

    African Journals Online (AJOL)

    The purpose of this study was to evaluate the diagnostic value of imaging-guided core needle biopsy for canine orbital mass diagnosis. A second excisional biopsy obtained during surgery or necropsy was used as the reference standard. A prospective feasibility study was conducted in 23 canine orbital masses at a single ...

  16. Diagnosis methods based on noise analysis at Cernavoda NPP, Romania

    International Nuclear Information System (INIS)

    Banica, Constantin; Dobrea, Dumitru

    1999-01-01

    This paper describes a recent noise analysis of the neutronic signals provided by in-core flux detectors (ICFD) and ion chambers (IC). This analysis is part of on-going program developed for Unit 1 of the Cernavoda NPP, Romania, with the following main objectives: - prediction of detector failures based on pattern recognition; - determination of fast excursions from steady states; - detection of abnormal mechanical vibrations in the reactor core. The introduction presents briefly the reactor, the location of ICFD's and IC's. The second section presents the data acquisition systems and their capabilities. The paper continues with a brief presentation of the numerical methods used for analysis (section 3). The most significant results can be found in section 4, while section 5 concludes about useful information that can be obtained from the neutronic signals at high power steady-state operation. (authors)

  17. Modelling the influence of noise of the image sensor for blood cells recognition in computer microscopy

    Science.gov (United States)

    Nikitaev, V. G.; Nagornov, O. V.; Pronichev, A. N.; Polyakov, E. V.; Dmitrieva, V. V.

    2017-12-01

    The first stage of diagnostics of blood cancer is the analysis of blood smears. The application of decision-making support systems would reduce the subjectivity of the diagnostic process and avoid errors, resulting in often irreversible changes in the patient's condition. In this regard, the solution of this problem requires the use of modern technology. One of the tools of the program classification of blood cells are texture features, and the task of finding informative among them is promising. The paper investigates the effect of noise of the image sensor to informative texture features with application of methods of mathematical modelling.

  18. Combat aircraft noise

    Science.gov (United States)

    Sgarbozza, M.; Depitre, A.

    1992-04-01

    A discussion of the characteristics and the noise levels of combat aircraft and of a transport aircraft in taking off and landing are presented. Some methods of noise reduction are discussed, including the following: operational anti-noise procedures; and concepts of future engines (silent post-combustion and variable cycle). Some measurement results concerning the noise generated in flight at great speeds and low altitude will also be examined. Finally, the protection of the environment of French air bases against noise will be described and the possibilities of regulation examined.

  19. Measurement of macroscopic plasma parameters with a radio experiment: Interpretation of the quasi-thermal noise spectrum observed in the solar wind

    Science.gov (United States)

    Couturier, P.; Hoang, S.; Meyer-Vernet, N.; Steinberg, J. L.

    1983-01-01

    The ISEE-3 SBH radio receiver has provided the first systematic observations of the quasi-thermal (plasma waves) noise in the solar wind plasma. The theoretical interpretation of that noise involves the particle distribution function so that electric noise measurements with long antennas provide a fast and independent method of measuring plasma parameters: densities and temperatures of a two component (core and halo) electron distribution function have been obtained in that way. The polarization of that noise is frequency dependent and sensitive to the drift velocity of the electron population. Below the plasma frequency, there is evidence of a weak noise spectrum with spectral index -1 which is not yet accounted for by the theory. The theoretical treatment of the noise associated with the low energy (thermal) proton population shows that the moving electrical antenna radiates in the surrounding plasma by Carenkov emission which becomes predominant at the low frequencies, below about 0.1 F sub P.

  20. Plasma Diagnostics of Coronal Dimming Events

    Science.gov (United States)

    Vanninathan, Kamalam; Veronig, Astrid M.; Dissauer, Karin; Temmer, Manuela

    2018-04-01

    Coronal mass ejections are often associated with coronal dimmings, i.e., transient dark regions that are most distinctly observed in Extreme Ultra-violet wavelengths. Using Atmospheric Imaging Assembly (AIA) data, we apply Differential Emission Measure diagnostics to study the plasma characteristics of six coronal dimming events. In the core dimming region, we find a steep and impulsive decrease of density with values up to 50%–70%. Five of the events also reveal an associated drop in temperature of 5%–25%. The secondary dimming regions also show a distinct decrease in density, but less strong, decreasing by 10%–45%. In both the core and the secondary dimming the density changes are much larger than the temperature changes, confirming that the dimming regions are mainly caused by plasma evacuation. In the core dimming, the plasma density reduces rapidly within the first 20–30 minutes after the flare start and does not recover for at least 10 hr later, whereas the secondary dimming tends to be more gradual and starts to replenish after 1–2 hr. The pre-event temperatures are higher in the core dimming (1.7–2.6 MK) than in the secondary dimming regions (1.6–2.0 MK). Both core and secondary dimmings are best observed in the AIA 211 and 193 Å filters. These findings suggest that the core dimming corresponds to the footpoints of the erupting flux rope rooted in the AR, while the secondary dimming represents plasma from overlying coronal structures that expand during the CME eruption.

  1. Listen to the noise: noise is beneficial for cognitive performance in ADHD.

    Science.gov (United States)

    Söderlund, Göran; Sikström, Sverker; Smart, Andrew

    2007-08-01

    Noise is typically conceived of as being detrimental to cognitive performance. However, given the mechanism of stochastic resonance, a certain amount of noise can benefit performance. We investigate cognitive performance in noisy environments in relation to a neurocomputational model of attention deficit hyperactivity disorder (ADHD) and dopamine. The Moderate Brain Arousal model (MBA; Sikström & Söderlund, 2007) suggests that dopamine levels modulate how much noise is required for optimal cognitive performance. We experimentally examine how ADHD and control children respond to different encoding conditions, providing different levels of environmental stimulation. Participants carried out self-performed mini tasks (SPT), as a high memory performance task, and a verbal task (VT), as a low memory task. These tasks were performed in the presence, or absence, of auditory white noise. Noise exerted a positive effect on cognitive performance for the ADHD group and deteriorated performance for the control group, indicating that ADHD subjects need more noise than controls for optimal cognitive performance. The positive effect of white noise is explained by the phenomenon of stochastic resonance (SR), i.e., the phenomenon that moderate noise facilitates cognitive performance. The MBA model suggests that noise in the environment, introduces internal noise into the neural system through the perceptual system. This noise induces SR in the neurotransmitter systems and makes this noise beneficial for cognitive performance. In particular, the peak of the SR curve depends on the dopamine level, so that participants with low dopamine levels (ADHD) require more noise for optimal cognitive performance compared to controls.

  2. A comparison of diagnostic performance of vacuum-assisted biopsy and core needle biopsy for breast microcalcification: a systematic review and meta-analysis.

    Science.gov (United States)

    Huang, Xu Chen; Hu, Xu Hua; Wang, Xiao Ran; Zhou, Chao Xi; Wang, Fei Fei; Yang, Shan; Wang, Gui Ying

    2018-03-16

    Core needle biopsy (CNB) and vacuum-assisted biopsy (VAB) are both popularly used breast percutaneous biopsies. Both of them have become reliable alternatives to open surgical biopsy (OSB) for breast microcalcification (BM). It is controversial that which biopsy method is more accurate and safer for BM. Hence, we conducted this meta-analysis to compare the diagnostic performance between CNB and VAB for BM, aiming to find out the better method. Articles according with including and excluding criteria were collected from the databases, PubMed, Embase, and the Cochrane Library. Preset outcomes were abstracted and pooled to find out the potential advantages in CNB or VAB. Seven studies were identified and entered final meta-analysis from initially found 138 studies. The rate of ductal carcinoma in situ (DCIS) underestimation was significantly lower in VAB than CNB group [risk ratio (RR) = 1.83, 95% confidence interval (CI) 1.40 to 2.40, p < 0.001]. The microcalcification retrieval rate was significantly higher in VAB than CNB group (RR = 0.89, 95% CI 0.81 to 0.98, p = 0.02), while CNB owned a significantly lower complication rate than VAB (RR = 0.18, 95% CI 0.03 to 0.93, p = 0.04). The atypical ductal hyperplasia (ADH) underestimation rates were not compared for the limited number of studies reporting this outcome. Compared with CNB, VAB shows better diagnostic performance in DCIS underestimation rate and microcalcification retrieval rate. However, CNB shows a significantly lower complication rate. More studies are needed to verify these findings.

  3. An image-processing method to detect sub-optical features based on understanding noise in intensity measurements.

    Science.gov (United States)

    Bhatia, Tripta

    2018-02-01

    Accurate quantitative analysis of image data requires that we distinguish between fluorescence intensity (true signal) and the noise inherent to its measurements to the extent possible. We image multilamellar membrane tubes and beads that grow from defects in the fluid lamellar phase of the lipid 1,2-dioleoyl-sn-glycero-3-phosphocholine dissolved in water and water-glycerol mixtures by using fluorescence confocal polarizing microscope. We quantify image noise and determine the noise statistics. Understanding the nature of image noise also helps in optimizing image processing to detect sub-optical features, which would otherwise remain hidden. We use an image-processing technique "optimum smoothening" to improve the signal-to-noise ratio of features of interest without smearing their structural details. A high SNR renders desired positional accuracy with which it is possible to resolve features of interest with width below optical resolution. Using optimum smoothening, the smallest and the largest core diameter detected is of width [Formula: see text] and [Formula: see text] nm, respectively, discussed in this paper. The image-processing and analysis techniques and the noise modeling discussed in this paper can be used for detailed morphological analysis of features down to sub-optical length scales that are obtained by any kind of fluorescence intensity imaging in the raster mode.

  4. Diagnostic performance of power doppler and ultrasound contrast agents in early imaging-based diagnosis of organ-confined prostate cancer: Is it possible to spare cores with contrast-guided biopsy?

    Science.gov (United States)

    Delgado Oliva, F; Arlandis Guzman, S; Bonillo García, M; Broseta Rico, E; Boronat Tormo, F

    2016-10-01

    To evaluate the diagnostic performance of gray scale transrectal ultrasound-B-mode US (BMUS), power Doppler (PDUS), and sonographic contrast (CEUS) in early imaging-based diagnosis of localized prostate cancer (PCa) and to compare the diagnostic profitability of randomized biopsy (RB), US-targeted prostate biopsy by means of PDUS and CEUS. A single-center, prospective, transversal, epidemiological study was conducted from January 2010 to January 2014. We consecutively included patients who an imaging study of the prostate with BMUS, PDUS, and CEUS was performed, followed by prostate biopsy due to clinical suspicion of prostate cancer (PSA 4-20ng/mL and/or rectal exam suggestive of malignancy). The diagnostic performance of BMUS, PDUS, and CEUS was determined by calculating the Sensitivity (S), Specificity (Sp), Predictive values (PV), and diagnostic odds ratio (OR) of the diagnosis tests and, for these variables, in the population general and based on their clinical stage according to rectal exam (cT1 and cT2). PCa detection rates determined by means of a randomized 10-core biopsy scheme were compared with detection rates of CEUS-targeted (SonoVue) 2-core biopsies. Of the initial 984 patients, US contrast SonoVue was administered to 179 (18.2%). The PCa detection rate by organ of BMUS/PDUS in the global population was 38% versus 43% in the subpopulation with CEUS. The mean age of the patients was 64.3±7.01years (95% CI, 63.75-64.70); mean total PSA was 8.9±3.61ng/mL (95% CI, 8.67-9.13) and the mean prostate volume was 56.2±29cc (95% CI, 54.2-58.1). The detection rate by organ of targeted biopsy with BMUS, PDUS, and CEUS were as follows: Global population (10.6, 8.2, 24.5%), stage cT1 (5.6, 4.2, 16.4%), and stage cT2 (32.4, 22.3, 43.5%). Comparing the detection rates of the CEUS-targeted biopsy and randomized biopsy, the following results were obtained: Global population (24.5% vs. 41.8%), stage cT1 (16% vs. 35%), and stage cT2 (43.5% vs. 66.6%), with a p value0

  5. Accuracy of Core Needle Biopsy Versus Fine Needle Aspiration Cytology for Diagnosing Salivary Gland Tumors

    Directory of Open Access Journals (Sweden)

    In Hye Song

    2015-03-01

    Full Text Available Background: Core needle biopsy is a relatively new technique used to diagnose salivary gland lesions, and its role in comparison with fine needle aspiration cytology needs to be refined. Methods: We compared the results of 228 ultrasound-guided core needle biopsy and 371 fine needle aspiration procedures performed on major salivary gland tumors with their postoperative histological diagnoses. Results: Core needle biopsy resulted in significantly higher sensitivity and more accurate tumor subtyping, especially for malignant tumors, than fine needle aspiration. No patient developed major complications after core needle biopsy. Conclusions: We recommend ultrasoundguided core needle biopsy as the primary diagnostic tool for the preoperative evaluation of patients with salivary gland lesions, especially when malignancy is suspected.

  6. Experimental determination of neutron lifetimes through macroscopic neutron noise in the IPEN/MB-01 reactor

    Energy Technology Data Exchange (ETDEWEB)

    Gonnelli, Eduardo; Diniz, Ricardo [Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP Travessa R-400, 05508-900, Cidade Universitaria, Sao Paulo (Brazil)

    2013-05-06

    The neutron lifetimes of the core, reflector, and global were experimentally obtained through macroscopic neutron noise in the IPEN/MB-01 reactor for five levels of subcriticality. The theoretical Auto Power Spectral Densities were derived by point kinetic equations taking the reflector effect into account, and one of the approaches consider an additional group of delayed neutrons.

  7. Prewhitening for Rank-Deficient Noise in Subspace Methods for Noise Reduction

    DEFF Research Database (Denmark)

    Hansen, Per Christian; Jensen, Søren Holdt

    2005-01-01

    A fundamental issue in connection with subspace methods for noise reduction is that the covariance matrix for the noise is required to have full rank, in order for the prewhitening step to be defined. However, there are important cases where this requirement is not fulfilled, e.g., when the noise...... has narrow-band characteristics, or in the case of tonal noise. We extend the concept of prewhitening to include the case when the noise covariance matrix is rank deficient, using a weighted pseudoinverse and the quotient SVD, and we show how to formulate a general rank-reduction algorithm that works...... also for rank deficient noise. We also demonstrate how to formulate this algorithm by means of a quotient ULV decomposition, which allows for faster computation and updating. Finally we apply our algorithm to a problem involving a speech signal contaminated by narrow-band noise....

  8. BWR noise spectra and application of noise analysis to FBR

    International Nuclear Information System (INIS)

    Nomura, T.

    1975-01-01

    Work related to noise analysis, in Tokyo Shibaura Electric Co. Ltd. (Toshiba) and Nippon Atomic Industry Group Co. Ltd. (NAIG) for the past several years is reviewed. After considering the Japan-United States Seminar on Reactor Noise Analysis in 1968, other subjects discussed were boiling water reactor noise analysis and work in relation to FBR. Parts of these are related to each other. For example, boiling detection and temperature fluctuations are problems pertinent to both fields. As the main problems in zero-power-reactor noise are now basically understood, only a brief description of the experiments involving the advanced two detector method is made. Focus is rather placed on the area of power plant noise. (author)

  9. Detectors for LIDAR type Thomson scattering diagnostics

    International Nuclear Information System (INIS)

    Hirsch, K.

    1991-04-01

    A report on the capability of the microchannel plate photomultiplier type (ITT F4128) presently used at the JET LIDAR Thomson Scattering System is given. Detailed investigation on time response, low noise amplification, shutter ratio, gating behaviour, linear mode of operation and saturation pulse recovery carried out during the design phase for LIDAR are presented. New investigation with respect to dc- and gated operation showed no measurable changes in sensitivity of this MCP photomultiplier. Comparing this type of detector with other MCP photomultipliers and with streak cameras some detection schemes for future LIDAR type diagnostic are proposed. (orig.)

  10. Utilization of noise analysis technique for mechanical vibrations estimation in the ATUCHA{sub 1} and Embalse Argentine NPP; Uso de la tecnica de analisis de ruido para la estimacion de vibraciones mecanicas en las centrales nucleares argentinas Atucha I y Embalse

    Energy Technology Data Exchange (ETDEWEB)

    Lescano, V.H.; Wentzeis, L.M. [Comision Nacional de Energia Atomica, Buenos Aires (Argentina). Centro Atomico Constituyentes; Guevara, M.; Moreno, C. [Nucleoelectrica Argentina S.A., Cordoba (Argentina). Central Nuclear Embalse; Pineyro, J. [Nucleoelectrica Argentina S.A., Buenos Aires (Argentina). Central Nuclear Atucha I

    1996-07-01

    In Argentine, comprehensive noise measurements have been performed with the reactor instrumentation of the PHWR power plant Atucha I and Embalse. The Embalse reactor is a CANDU-600 (600 Mwe) type pressurized heavy water reactor. It's a heavy water moderator and heavy water cooled natural uranium fueled pressure tube system. Signal of vanadium and platinum type in core-self power neutron detectors of ex-core ion chambers and of a moderator pressure sensor have been recorded and analysed. The vibration of reactor internals as vertical and horizontal in-core neutron flux detectors units and the coolant channels systems, consisting of calandria and pressure tubes with fuel bundles, have been identified and monitored during normal reactor operation. Atucha I, is a PHWR reactor natural uranium fueled, and heavy water moderated and cooled. Neutron noise techniques using of ex-core ionization chambers and in-core Vanadium SPND's were implemented, among others, in order to produce early detection of anomalous vibrations in the reactor internals. Noise analysis was successfully performed to identify normal and peculiar vibrations in particular reactor internals. (author)

  11. Turbofan Noise Studied in Unique Model Research Program in NASA Glenn's 9- by 15-Foot Low-Speed Wind Tunnel

    Science.gov (United States)

    Hughes, Christopher E.

    2001-01-01

    A comprehensive aeroacoustic research program called the Source Diagnostic Test was recently concluded in NASA Glenn Research Center's 9- by 15-Foot Low Speed Wind Tunnel. The testing involved representatives from Glenn, NASA Langley Research Center, GE Aircraft Engines, and the Boeing Company. The technical objectives of this research were to identify the different source mechanisms of noise in a modern, high-bypass turbofan aircraft engine through scale-model testing and to make detailed acoustic and aerodynamic measurements to more fully understand the physics of how turbofan noise is generated.

  12. Noise Gating Solar Images

    Science.gov (United States)

    DeForest, Craig; Seaton, Daniel B.; Darnell, John A.

    2017-08-01

    I present and demonstrate a new, general purpose post-processing technique, "3D noise gating", that can reduce image noise by an order of magnitude or more without effective loss of spatial or temporal resolution in typical solar applications.Nearly all scientific images are, ultimately, limited by noise. Noise can be direct Poisson "shot noise" from photon counting effects, or introduced by other means such as detector read noise. Noise is typically represented as a random variable (perhaps with location- or image-dependent characteristics) that is sampled once per pixel or once per resolution element of an image sequence. Noise limits many aspects of image analysis, including photometry, spatiotemporal resolution, feature identification, morphology extraction, and background modeling and separation.Identifying and separating noise from image signal is difficult. The common practice of blurring in space and/or time works because most image "signal" is concentrated in the low Fourier components of an image, while noise is evenly distributed. Blurring in space and/or time attenuates the high spatial and temporal frequencies, reducing noise at the expense of also attenuating image detail. Noise-gating exploits the same property -- "coherence" -- that we use to identify features in images, to separate image features from noise.Processing image sequences through 3-D noise gating results in spectacular (more than 10x) improvements in signal-to-noise ratio, while not blurring bright, resolved features in either space or time. This improves most types of image analysis, including feature identification, time sequence extraction, absolute and relative photometry (including differential emission measure analysis), feature tracking, computer vision, correlation tracking, background modeling, cross-scale analysis, visual display/presentation, and image compression.I will introduce noise gating, describe the method, and show examples from several instruments (including SDO

  13. Adaptive Noise Suppression of Pediatric Lung Auscultations With Real Applications to Noisy Clinical Settings in Developing Countries

    Science.gov (United States)

    Emmanouilidou, Dimitra; McCollum, Eric D.; Park, Daniel E.

    2015-01-01

    Goal Chest auscultation constitutes a portable low-cost tool widely used for respiratory disease detection. Though it offers a powerful means of pulmonary examination, it remains riddled with a number of issues that limit its diagnostic capability. Particularly, patient agitation (especially in children), background chatter, and other environmental noises often contaminate the auscultation, hence affecting the clarity of the lung sound itself. This paper proposes an automated multiband denoising scheme for improving the quality of auscultation signals against heavy background contaminations. Methods The algorithm works on a simple two-microphone setup, dynamically adapts to the background noise and suppresses contaminations while successfully preserving the lung sound content. The proposed scheme is refined to offset maximal noise suppression against maintaining the integrity of the lung signal, particularly its unknown adventitious components that provide the most informative diagnostic value during lung pathology. Results The algorithm is applied to digital recordings obtained in the field in a busy clinic in West Africa and evaluated using objective signal fidelity measures and perceptual listening tests performed by a panel of licensed physicians. A strong preference of the enhanced sounds is revealed. Significance The strengths and benefits of the proposed method lie in the simple automated setup and its adaptive nature, both fundamental conditions for everyday clinical applicability. It can be simply extended to a real-time implementation, and integrated with lung sound acquisition protocols. PMID:25879837

  14. Nodewise analytical calculation of the transfer function

    International Nuclear Information System (INIS)

    Makai, Mihaly

    1994-01-01

    The space dependence of neutron noise has so far been mostly investigated in homogeneous core models. Application of core diagnostic methods to locate a malfunction requires however that the transfer function be calculated for real, inhomogeneous cores. A code suitable for such purpose must be able to handle complex arithmetic and delta-function source. Further requirements are analytical dependence in one spatial variable and fast execution. The present work describes the TIDE program written to fulfil the above requirements. The core is subdivided into homogeneous, square assemblies. An analytical solution is given, which is a generalisation of the inhomogeneous response matrix method. (author)

  15. Noise sensitivity and reactions to noise and other environmental conditions

    NARCIS (Netherlands)

    Miedema, H.M.E.; Vos, H.

    2003-01-01

    This article integrates findings from the literature and new results regarding noise sensitivity. The new results are based on analyses of 28 combined datasets (N=23 038), and separate analyses of a large aircraft noise study (N=10939). Three topics regarding noise sensitivity are discussed, namely,

  16. Adaptive noise cancellation

    International Nuclear Information System (INIS)

    Akram, N.

    1999-01-01

    In this report we describe the concept of adaptive noise canceling, an alternative method of estimating signals corrupted by additive noise of interference. The method uses 'primary' input containing the corrupted signal and a 'reference' input containing noise correlated in some unknown way with the primary noise, the reference input is adaptively filtered and subtracted from the primary input to obtain the signal estimate. Adaptive filtering before subtraction allows the treatment of inputs that are deterministic or stochastic, stationary or time variable. When the reference input is free of signal and certain other conditions are met then noise in the primary input can be essentially eliminated without signal distortion. It is further shown that the adaptive filter also acts as notch filter. Simulated results illustrate the usefulness of the adaptive noise canceling technique. (author)

  17. Prediction of broadband trailing edge noise from a NACA0012 airfoil using wall-modeled large-eddy simulation

    Science.gov (United States)

    Mehrabadi, Mohammad; Bodony, Daniel

    2017-11-01

    In modern high-bypass ratio turbofan engines, the reduction of jet exhaust noise through engine design has increased the acoustic importance of the main fan to the point where it can be the primary source of noise in the fight direction of an airplane. While fan noise has been reduced by improved fan designs, its broadband component, originating from the interaction of turbulent flow with a solid surface, still remains an issue. Broadband fan noise is generated by several mechanisms, usually involving a turbulent boundary layer interacting with a solid surface. To prepare for a wall modeled large eddy simulation (WMLES) of the NASA/GE source diagnostic test fan, we study the broadband noise due to the turbulent flow on a NACA0012 airfoil at zero degree angle-of-attack, a chord-based Reynolds number of 408,000, and a Mach number of 0.115 using WMLES. We investigate the prediction of transition-to-turbulence and sound generation from the WMLES and examine its predictability compared with available experimental and DNS datasets for the same flow conditions. Verification of WMLES for such a canonical problem is crucial since it provides useful insight about the WMLES approach before using it for broadband fan noise prediction. AeroAcoustics Research Consortium.

  18. Critical Low-Noise Technologies Being Developed for Engine Noise Reduction Systems Subproject

    Science.gov (United States)

    Grady, Joseph E.; Civinskas, Kestutis C.

    2004-01-01

    NASA's previous Advanced Subsonic Technology (AST) Noise Reduction Program delivered the initial technologies for meeting a 10-year goal of a 10-dB reduction in total aircraft system noise. Technology Readiness Levels achieved for the engine-noise-reduction technologies ranged from 4 (rig scale) to 6 (engine demonstration). The current Quiet Aircraft Technology (QAT) project is building on those AST accomplishments to achieve the additional noise reduction needed to meet the Aerospace Technology Enterprise's 10-year goal, again validated through a combination of laboratory rig and engine demonstration tests. In order to meet the Aerospace Technology Enterprise goal for future aircraft of a 50- reduction in the perceived noise level, reductions of 4 dB are needed in both fan and jet noise. The primary objectives of the Engine Noise Reduction Systems (ENRS) subproject are, therefore, to develop technologies to reduce both fan and jet noise by 4 dB, to demonstrate these technologies in engine tests, and to develop and experimentally validate Computational Aero Acoustics (CAA) computer codes that will improve our ability to predict engine noise.

  19. Diagnostic Performance on Low Dose Computed Tomography For Acute Appendicitis Among Attending and Resident Radiologists

    International Nuclear Information System (INIS)

    Chang, Chih-Chen; Wong, Yon-Cheong; Wu, Cheng-Hsien; Chen, Huan-Wu; Wang, Li-Jen; Lee, Yu-Hsien; Wu, Patricia Wanping; Irama, Wiwan; Chen, Wei Yuan; Chang, Chee-Jen

    2016-01-01

    Low-dose computed tomography (LDCT) techniques can reduce exposure to radiation. Several previous studies have shown that radiation dose reduction in LDCT does not decrease the diagnostic performance for appendicitis among attending radiologists. But, the LDCT diagnostic performance for acute appendicitis in radiology residents with variable training levels has not been well discussed. To compare inter-observer and intra-observer differences of diagnostic performance on non-enhanced LDCT (NE-LDCT) and contrast-enhanced standard dose CT (CE-SDCT) for acute appendicitis among attending and resident radiologists. This retrospective study included 101 patients with suspected acute appendicitis who underwent NE-LDCT and CE-SDCT. The CT examinations were interpreted and recorded on a five-point scale independently by three attending radiologists and three residents with 4, 1 and 1 years of training. Diagnostic performance for acute appendicitis of all readers on both examinations was represented by area under receiver operating characteristic (ROC) curves. Inter-observer and intra-observer AUC values were compared using Jackknife FROC software on both modalities. The diagnostic accuracy of each reader on NE-LDCT was compared with body mass index (BMI) subgroups and noise using independent T test. Diagnostic performances for acute appendicitis were not statistically different for attending radiologists at both examinations. Better performance was noted on the CE-SDCT with a borderline significant difference (P = 0.05) for senior radiology resident. No statistical difference of AUC values was observed between attending radiologists and fourth year resident on both examinations. Statistically signifi@@cant differences of AUC values were observed between attending radiologists and first year residents (P = 0.001 ~ 0.018) on NE-LDCT. Diagnostic accuracies of acute appendicitis on NE-LDCT for each reader were not significantly related to BMI or noise. Attending radiologists

  20. Phenomenon of entropic stochastic resonance with asymmetric dichotomous noise and white noise

    International Nuclear Information System (INIS)

    Guo, Feng; Li, Shao-Fu; Cheng, Xiao-Feng

    2012-01-01

    The entropic stochastic resonance (ESR) in a confined system subject to asymmetric dichotomous noise, white noise, and a periodic square-wave signal is investigated. Under the adiabatic approximation condition, by use of the properties of the dichotomous noise, we obtain the expression of the output signal-to-noise ratio (SNR) based on two-state theory. The SNR is shown to be a nonmonotonic function of the strength and asymmetry of the dichotomous noise, the intensity of the white noise, and the amplitude of the square-wave signal. The SNR varies non-monotonically with increases in the parameters of the confined structure. The influence of the correlation rate of the dichotomous noise and the frequency of the external constant force on the SNR is also discussed.