WorldWideScience

Sample records for cordon counts

  1. A Trial-and-Error Method with Autonomous Vehicle-to-Infrastructure Traffic Counts for Cordon-Based Congestion Pricing

    Directory of Open Access Journals (Sweden)

    Zhiyuan Liu

    2017-01-01

    Full Text Available This study proposes a practical trial-and-error method to solve the optimal toll design problem of cordon-based pricing, where only the traffic counts autonomously collected on the entry links of the pricing cordon are needed. With the fast development and adoption of vehicle-to-infrastructure (V2I facilities, it is very convenient to autonomously collect these data. Two practical properties of the cordon-based pricing are further considered in this article: the toll charge on each entry of one pricing cordon is identical; the total inbound flow to one cordon should be restricted in order to maintain the traffic conditions within the cordon area. Then, the stochastic user equilibrium (SUE with asymmetric link travel time functions is used to assess each feasible toll pattern. Based on a variational inequality (VI model for the optimal toll pattern, this study proposes a theoretically convergent trial-and-error method for the addressed problem, where only traffic counts data are needed. Finally, the proposed method is verified based on a numerical network example.

  2. Cordon Pricing Considering Air Pollutants Emission

    Directory of Open Access Journals (Sweden)

    Shahriar Afandizadeh

    2016-04-01

    Full Text Available This paper considers the issue of air pollutants emission for the optimal and sustainable determination of cordon location, toll level, and price of park and ride (P&R. Although air pollutants emission decreases within the cordon by the implementation of cordon pricing scheme, it may increase outside the cordon and the whole network. Hence, air pollutants emission may only transfer from inside of the cordon to its outside. Therefore, in this paper, a multi-objective bi-level optimization model is developed. A solution algorithm is also presented based on the second version of strength Pareto evolutionary algorithm (SPEA2. The results reveal that this multi-objective model can be a useful tool for the sustainable and optimal design of the cordon and P&R scheme. In addition, cordon pricing is a multi-objective problem. Therefore, it is necessary to consider air pollutants emission. By choosing another non-dominated result in the solution space, air pollutants emission outside the cordon and the whole network can be reduced without a significant reduction in social welfare.

  3. Le kyste hydatique du cordon spermatique: une localisation exceptionnelle

    Science.gov (United States)

    Hamdane, Mohamed Moncef; Bougrine, Fethi; Msakni, Issam; Dhaoui-Ghozzi, Amen; Bouziani, Ammar

    2011-01-01

    L’ hydatidose est une anthropo-zoonose due au développement chez l'homme de la forme larvaire du taenia Echinococcus granulosis. La plupart des kystes hydatiques se localisent dans le foie et les poumons. Le kyste hydatique du cordon spermatique est extrêmement rare avec seulement 4 cas rapportés dans la littérature. Les auteurs rapportent dans cet article un nouveau cas d'hydatidose du cordon spermatique. Il s'agissait d'un homme de 40 ans qui consultait pour des douleurs scrotales évoluant depuis huit mois. L'examen clinique a mis en évidence une tuméfaction mobile, inguino-scrotale, droite. L’échographie testiculaire a objectivé une hernie inguinale droite associée à deux kystes épididymaires bilatéraux. Le patient a été opéré pour cure de son hernie avec découverte en per-opératoire d'un kyste du cordon spermatique qui a été réséqué. L'examen anatomopathologique a conclu à une hydatidose du cordon spermatique. PMID:22384304

  4. Social Optimality of Cordon Area Congestion Pricing in an Monocentric City

    Directory of Open Access Journals (Sweden)

    Harya S Dillon

    2015-04-01

    Full Text Available Abstrak. Kemacetan lalu lintas merupakan epidemi global yang telah melumpuhkan banyak kota. Dari sudut pandang ekonomi mikro, kemacetan dapat dipandang sebagai eksternalitas negatif dimana diperlukan bea Pigovian sebagai solusi atas ekuilibrium yang kurang optimal tersebut. Eksternalitas ini dirasakan dalam bentuk tundaan perjalanan dan pembangunan kota yang rakus lahan. Meskipun teori mengenai ketepatgunaan bea kemacetan (congestion pricing telah mapan sejak akhir 1970-an, penerapan dan implementasi kebijakan tertunda oleh kendala teknologi. Salah satu bentuk implementasi bayaran kemacetan yang sering dijumpai adalah bea lintas-kordon (cordon charging, dimana penglaju yang masuk ke wilayah pusat dibebani sejumlah biaya. Ketepatgunaan dari bea lintas-kordon telah dikaji secara empiris dan juga dengan simulasi numerik, namun penjelasan teoretis belum dilakukan secara tuntas. Penulis mengembangkan model kota monosentris untuk meneliti dampak kebijakan bea lintas-kordon pada kepadatan kota dan permintaan akan lahan kota (equilibrium rent. Bea lintas-kordon akan menaikkan harga lahan di pusat kota dan memperbesar gradien kurva tawaran-sewa (bid-rent curve. Namun yang lebih penting untuk diperhatikan adalah bahwa besaran ini ditentukan oleh parameter kordon. Dengan demikian dapat disimpulkan bahwa daya manfaat kebijakan ini sangat dipengaruhi oleh pilihan parameter kordon yang dibuat perencana.Kata kunci. kemacetan, bea lintas-kordon, kota monosentris, struktur kotaAbstract. Traffic congestion is a global epidemic that at time has put cities to a state of paralysis. From a microeconomics point of view, congestion can be approached as a negative externality that merits a Pigovian tax to correct the suboptimal equilibrium. Externalities manifest in delays and wasteful urbanization. While the efficiency of congestion pricing has been well established since the late 1970s, policy adoption and implementation have been delayed due to technological

  5. Development of a Model for a Cordon Pricing Scheme Considering Environmental Equity: A Case Study of Tehran

    Directory of Open Access Journals (Sweden)

    Shahriar Afandizadeh

    2016-02-01

    Full Text Available Congestion pricing strategy has been recognized as an effective countermeasure in the practical field of urban traffic congestion mitigation. Despite the positive effects of congestion pricing, its implementation has faced problems. This paper investigates the issue of environmental equity in cordon pricing and a park-and-ride scheme. Although pollution decreases inside the cordon by implementation of cordon pricing, air pollutants emission may increase in some links and in the whole network. Therefore, an increase in air emissions in the network means more emission outside the cordon. In fact, due to the implementation of this policy, air pollutants emission may transfer from inside to outside the cordon, creating a type of environmental inequity. To reduce this inequity, a bi-level optimization model with an equity constraint is developed. The proposed solution algorithm based on the second version of the strength Pareto evolutionary algorithm (SPEA2 is applied to the city network in Tehran. The results revealed that it seems reasonable to consider environmental equity as an objective function in cordon pricing. In addition, we can create a sustainable situation for the transportation system by improving environmental inequity with a relatively low reduction in social welfare. Moreover, there are environmental inequity impacts in real networks, which should be considered in the cordon pricing scheme.

  6. Undirected (solitary birdsong in female and male blue-capped cordon-bleus (Uraeginthus cyanocephalus and its endocrine correlates.

    Directory of Open Access Journals (Sweden)

    Nicole Geberzahn

    Full Text Available BACKGROUND: Birdsong is a popular model system in research areas such as vocal communication, neuroethology or neuroendocrinology of behaviour. As most research has been conducted on species with male-only song production, the hormone-dependency of male song is well established. However, female singing and its mechanisms are poorly understood. METHODOLOGY/PRINCIPAL FINDINGS: We characterised the song and its endocrine correlates of blue-capped cordon-bleus (Uraeginthus cyanocephalus, a species in which both sexes sing. Like other estrildids, they produce directed song during courtship and undirected (or solitary song in isolation, i.e. when the mate is not visible or absent. We compare solitary song of blue-capped cordon-bleus to published descriptions of the song of its relative, the zebra finch (Taeniopygia guttata. Solitary song of cordon-bleus shared some overall song features with that of zebra finches but differed in spectro-temporal song features, sequential stereotypy and sequential organisation. The song of cordon-bleus was dimorphic with respect to the larger size of syllable repertoires, the higher song duration and the lower variability of pitch goodness (measuring the pureness of harmonic sounds in males. However, in both sexes the overall plasma testosterone concentrations were low (ca. 300 pg/ml and did not correlate with the sexually dimorphic song motor pattern. Despite such low concentrations, the increase in the rate of solitary song coincided with an increase in the level of testosterone. Furthermore, the latency to start singing after the separation from the mate was related to hormone levels. CONCLUSIONS/SIGNIFICANCE: Our findings suggest that the occurrence of solitary song but not its motor pattern might be under the control of testosterone in female and male cordon-bleus.

  7. L-045: EPR-First Responders: Evaluation of the risk and establishment of inner cordoned area

    International Nuclear Information System (INIS)

    2011-01-01

    This conference is about the risk evaluation knowledge by the first responders in a radiological emergency. They have to establish the inner cordoned area , identify dangerous symbols , devices, packages, radioactive source, material and equipment used

  8. Análise numérica da pressão de ruptura de tubos à base de borracha e cordonéis poliméricos

    Directory of Open Access Journals (Sweden)

    Maikson Luiz Passaia Tonatto

    2015-02-01

    Full Text Available Este trabalho tem como objetivo estudar o efeito de cordonéis de poliéster, poliamida, poliaramida e híbrido poliamida/poliaramida como reforço de elastômeros utilizados na fabricação de mangotes. O comportamento do tubo elastomérico reforçado com cordonéis sob pressão interna foi simulado com análise por elementos finitos (FEA utilizando-se elementos chamados reinforcement bars. Foram realizados ensaios para se obter as propriedades em tração dos cordonéis para alimentar o modelo. O cordonel de poliaramida apresentou a maior tensão de ruptura, o de poliamida maior deformação na ruptura, e o híbrido apresentou valores intermediários. O critério de falha adotado para o tubo consistiu na análise do nível de carga no cordonel. Foram avaliadas, principalmente, a pressão e a deformação de ruptura do tubo elastomérico simulado frente à variação do ângulo de orientação dos cordonéis. Os resultados mostraram que ângulos próximos a 55° tornam o tubo mais resistente porém menos rígido no sentido longitudinal.

  9. Aislamiento de polisacáridos a partir de cordones umbilicales humanos

    Directory of Open Access Journals (Sweden)

    Guillermo Lago

    2002-12-01

    Full Text Available Se realizó el aislamiento y caracterización de polisacáridos obtenidos a partir de cordones umbilicales humanos mediante una modificación a la técnica de Danishevsky y Bella. Se trataron los cordones con solución de cloruro de sodio bajo condiciones de temperatura y agitación controlada y se precipitaron los polisacáridos mediante la adición de una disolución de bromuro de cetiltrimetilamonio al 1 %. Se resuspendió el sedimento obtenido en una solución de cloruro de sodio 0,4 mol/L eliminando algunas impurezas que no se solubilizan a esta fuerza iónica mediante centrifugación y se precipitó el producto de interés mediante la adición de etanol al sobrenadante, caracterizándose por métodos químicos. El producto puede ser empleado como materia prima para obtener un gel cicatrizante en la Industria Médico-Farmacéutica.The polysaccharides obtained from human umbilical cords by a modification of Danishevsky and Bella’s technique were isolated and characterized. The cords were treated with a sodium chloride solution under controlled temperature and agitation conditions. The polysaccharides were precipitated by adding a disolution of cetyltrimethylammonium 1 %. The sediment obtained in a sodium chloride solution 0.4 mol/L was resuspended, eliminating some impurities that were not soluble at this ionic force by centrifugation. The product of interest was precipitated by adding ethanol to the supernadant and it was characterized by chemical methods. This product may be used as a raw material to obtain a healing gel in the Medicopharmaceutical Industry.

  10. Memory effect triggered by exceptional event: the Rio Cordon study case

    Science.gov (United States)

    Rainato, Riccardo; Mao, Luca; Picco, Lorenzo; Garcia-Rama, Adriana; Aristide Lenzi, Mario

    2016-04-01

    In the mountain environment, the steep channels play a key-role in the drainage networks. Notably, the sediment transport processes that here occur, can affect aspects as the geomorphic changes, channel evolution, reservoir management, infrastructure design and hazard assessment. Due to the complex and changeable hydraulic and morphological features that characterize the mountain environment, the steep channels can exhibit fluvial and/or debris-flow transport with magnitude of sediment delivery that, in the same basin, may strongly vary from event to event. In the light of these challenging conditions, appears clear as an accurate monitoring and investigation of sediment dynamics is of critical importance in the steep mountain channels. Such monitoring has even more significance if it is maintained over long-period, enabling to investigate even the role of high magnitude/low frequency events. Using a dataset 29 years-wide, this work aims to investigate the temporal trend of sediment dynamic in the Rio Cordon (Eastern Italian Alps). The Rio Cordon is a steep mountain channel (mean slope = 13%) characterized by step-pool and riffle-pool morphology. The basin (5 km2)exhibits a prevalent nivo-pluvial runoff regime. Since 1986, the catchment is equipped with a monitoring station, that continuously records water discharge, bedload and suspended load (at 1 hr intervals, and 5 min intervals during floods). In September 1994 an exceptional event (RI > 100 years) occurred in the study site, mobilizing about 4000 tons of material. Currently, the structure is managed by ARPA Veneto - Regional Department for Land Safety. In terms of magnitude, the 31 floods recorded by the monitoring station show a wide range of hydraulic forcing (i.e. peak discharge and effective runoff) and amount transported. Specifically, Qpeak ranges within one order of magnitude (1.02 - 10.42 m3 s-1), while the amount of bedload and suspended load varies by more than 3 orders (i.e. 0.9 t transported by

  11. Impact du cordon sableux déposé à l’embouchure du site Ramsar de l’estuaire de l’Oued Massa (Maroc sur l’hydrologie et l’avifaune

    Directory of Open Access Journals (Sweden)

    M. EL BEKKAY

    2014-03-01

    Full Text Available Situé sur un des principaux axes de migration des oiseaux d’eau entre l’Europe et l’Afrique, l’estuaire de l’oued Massa, inscrit dans la liste Ramsar depuis 2005, a connu des modifications hydrologiques importantes, à la suite de l’installation en amont du barrage Youssef Ben Tachfine en 1972. En effet, l’installation de ce barrage a induit le dépôt d’un cordon de sable au niveau de l’embouchure, séparant les eaux de l’oued de celles de l’océan atlantique et transformant le site d’un écosystème estuarien en écosystème lagunaire. Le site est aussi le siège de changements irréguliers, enregistrés lors de disparitions temporaires du cordon de sable survenues à la suite des lâchés de barrages lors des précipitations abondantes comme c’était le cas en 1983, 1992, 1996 et 2010. Ce travail de recherche vise à étudier l’effet des modifications de l’écosystème à la suite de la disparition du cordon du sable de l’embouchure, sur l’évolution des paramètres physicochimiques du milieu et sur les oiseaux fréquentent le site. Pour ce faire plusieurs paramètres physicochimiques de l’eau (pH, oxygène dissous, température, salinité, azote ammoniacal, ortho-phosphate et nitrates ont été mesurés avant (2009 et après (2010 la dernière disparition du cordon de sable survenue en février 2010. Concernant l’influence des changements de l’écosystème sur l’avifaune, elle a été évaluée grâce au suivi de 7 espèces d’oiseaux parmi les plus caractéristiques de ce site Ramsar. Les résultats obtenus montrent que le passage de l’embouchure d’un état lagunaire vers un état estuarien à la suite de la disparition du cordon sableux s’est traduit principalement par l’amélioration de la qualité des eaux par accroissement des valeurs de l’oxygène dissous. Le milieu a connu aussi une augmentation de la salinité. Concernant les oiseaux d’eau, les sept espèces étudiées ont

  12. Part I: Improvement of the microbiological safety of two chilled semi-prepared meals by gamma radiation

    International Nuclear Information System (INIS)

    Farkas, J.; Andrassy, E.; Meszaros, L.; Beczner, J.; Polyak-Feher, K.; Gaal, O.; Lebovics, V.K.; Lugasi, A.

    2009-01-01

    Experimental batches of a stuffed pasta product, tortellini and slightly pre-fried breaded reconstituted turkey meat steaks with cheese and ham filling, cordon bleu, were prepared according to commercial recipes, then inoculated to 10 4 CFU/g with Staphylococcus aureus (in the case of tortellini) and to 10 6 CFU/g with Listeria monocytogenes (in the case of cordon bleu) prior to packaging in plastic pouches under a gas atmosphere of 20% CO 2 and 80% N 2 . The inoculated packages were irradiated at 3 kGy (tortellini) and 2 kGy (cordon bleu) by a 60 Co source. The applied radiation doses were sensorially acceptable with these products. The experimental batches of tortellini were stored at 15 deg. C, while the cordon bleu samples were stored at 5 and 9 deg. C, respectively. Non-irradiated samples were kept together with the respective irradiated ones. Storage was continued for 4 weeks and microbiological tests were performed before and after irradiation, and subsequently after every 7 d. Besides selective estimation of the counts of the test organisms, total aerobic counts, and in the case of cordon bleu, colony counts of lactic acid bacteria, Enterobacteriaceae, sulphite reducing Clostridia, yeasts and moulds were also selectively estimated. The 3 kGy dose reduced the S. aureus count in tortellini below the detection limit (lg CFU = 0.26), and it remained undetectably low in the irradiated samples during the whole 28 d of storage, while the S. aureus count in the non-irradiated samples increased up to 10 8 CFU/g by the 8th day. The Listeria count in the cordon bleu was reduced by irradiation from the initial lg CFU/g = 6.1 to lg CFU/g = 3.5. At 5 deg. C storage, this residual count remained stagnant up to 3 - 4 weeks, but started to increase at 9 deg. C after one week. In the non-irradiated samples, the Listeria count increased hundredfold over 4 weeks at 5 deg. C, and over 2 weeks at 9 deg. C. Sulphite reducing Clostridia were, and remained, undetectable (lg CFU

  13. An update of the sediment fluxes investigation in the Rio Cordon (Italy after 25 years of monitoring

    Directory of Open Access Journals (Sweden)

    Lorenzo Picco

    2012-12-01

    Full Text Available Quantification of bed-load transport in high-gradient mountain streams is important, but the field data needed to test transport models are scarce and difficult to obtain. In the present study, we describe the experimental station for monitoring water and sediment fluxes built in 1985 on the Rio Cordon, a small step-pool channel in the eastern Italian Alps. The measuring station consists of an inclined frame that separates fine from coarse sediments (D>20 mm, which are continuously measured by a series of ultrasonic sensors fitted above a storage area. The acquired 25-year dataset, which comprises a high-magnitude/ low-recurrence flood event, has allowed a magnitude-frequency analysis of bed-load volumes to be performed. Results from a combined frequency analysis of peak water discharge and total bed-load volumes are presented. In addition, the integration between the sediment transport dataset and the repeated surveys of sediment sources and of channel changes allowed us to assess the geomorphological effectiveness of different flood events. Despite the importance of the experimental station for making these bed-load observations possible, its maintenance costs are not low and these may have an impact on its future existence. At the same time, improving current instrumentation and future installations with novel technology would make the station an ideal location for calibrating surrogate techniques for sediment transport monitoring.

  14. Climate-scale modelling of suspended sediment load in an Alpine catchment debris flow (Rio Cordon-northeastern Italy)

    Science.gov (United States)

    Diodato, Nazzareno; Mao, Luca; Borrelli, Pasquale; Panagos, Panos; Fiorillo, Francesco; Bellocchi, Gianni

    2018-05-01

    Pulsing storms and prolonged rainfall can drive hydrological damaging events in mountain regions with soil erosion and debris flow in river catchments. The paper presents a parsimonious model for estimating climate forcing on sediment loads in an Alpine catchment (Rio Cordon, northeastern Italian Alps). Hydroclimatic forcing was interpreted by the novel CliSMSSL (Climate-Scale Modelling of Suspended Sediment Load) model to estimate annual sediment loads. We used annual data on suspended-solid loads monitored at an experimental station from 1987 to 2001 and on monthly precipitation data. The quality of sediment load data was critically examined, and one outlying year was identified and removed from further analyses. This outlier revealed that our model underestimates exceptionally high sediment loads in years characterized by a severe flood event. For all other years, the CliSMSSL performed well, with a determination coefficient (R2) equal to 0.67 and a mean absolute error (MAE) of 129 Mg y-1. The calibrated model for the period 1986-2010 was used to reconstruct sediment loads in the river catchment for historical times when detailed precipitation records are not available. For the period 1810-2010, the model results indicate that the past centuries have been characterized by large interannual to interdecadal fluctuations in the conditions affecting sediment loads. This paper argues that climate-induced erosion processes in Alpine areas and their impact on environment should be given more attention in discussions about climate-driven strategies. Future work should focus on delineating the extents of these findings (e.g., at other catchments of the European Alpine belt) as well as investigating the dynamics for the formation of sediment loads.

  15. A comparative ecophysiology of ecolly (vitis vinifera l.) under the traditional independent long-stem pruning and crawled cordon training

    International Nuclear Information System (INIS)

    Nan, L.; Zhao, X.; Liu, L.; Wang, H.; Li, H.

    2014-01-01

    The aim of this study was to compare the ecophysiology character of Ecolly grape (Vitis vinifera L.) with the new technology-single crawled cordon training (SCCT) and traditional method-independent long-stem pruning (ILSP). The connections among net photosynthesis rate (Pn), transpiration rate (Tr), instantaneous water utilization efficiency (WUEi), stomatal conductance (Cs) and intercellular CO/sub 2/ concentration (Ci) were always mutual and inextricable in the trial. The leaves in every stage had the highest Pn respectively when growing under the light irradiance of the different period. The ILSP showed a lower total photosynthetic capacity than the SCCT. There was the total semblable Tr for two pruning plants, but lower Tr in ILSP at the every position of the prior stage and riping stage (PS and RS) excluding the growing stage (GS). The WUEi declined because of the net CO/sub 2/ assimilation saturated and the transpiration constantly fleetly increased before the photosynthetic active radiation (PAR) increased to 600 meu mol m/sup -2/ s/sup -1/. The increased WUEis from the first to the second stage deduced that stomatal closure at high irradiance reduced more Tr than Pn, while the values decreased again in the last stage indicated that stomatal opening at low irradiance added more Tr than Pn. These results suggested that it may be possible technology to change trellises in order to obtain better ecophysiology character in this study. The growth variability of vine may be affected by a particular training style. (author)

  16. Compton suppression gamma-counting: The effect of count rate

    Science.gov (United States)

    Millard, H.T.

    1984-01-01

    Past research has shown that anti-coincidence shielded Ge(Li) spectrometers enhanced the signal-to-background ratios for gamma-photopeaks, which are situated on high Compton backgrounds. Ordinarily, an anti- or non-coincidence spectrum (A) and a coincidence spectrum (C) are collected simultaneously with these systems. To be useful in neutron activation analysis (NAA), the fractions of the photopeak counts routed to the two spectra must be constant from sample to sample to variations must be corrected quantitatively. Most Compton suppression counting has been done at low count rate, but in NAA applications, count rates may be much higher. To operate over the wider dynamic range, the effect of count rate on the ratio of the photopeak counts in the two spectra (A/C) was studied. It was found that as the count rate increases, A/C decreases for gammas not coincident with other gammas from the same decay. For gammas coincident with other gammas, A/C increases to a maximum and then decreases. These results suggest that calibration curves are required to correct photopeak areas so quantitative data can be obtained at higher count rates. ?? 1984.

  17. EcoCount

    Directory of Open Access Journals (Sweden)

    Phillip P. Allen

    2014-05-01

    Full Text Available Techniques that analyze biological remains from sediment sequences for environmental reconstructions are well established and widely used. Yet, identifying, counting, and recording biological evidence such as pollen grains remain a highly skilled, demanding, and time-consuming task. Standard procedure requires the classification and recording of between 300 and 500 pollen grains from each representative sample. Recording the data from a pollen count requires significant effort and focused resources from the palynologist. However, when an adaptation to the recording procedure is utilized, efficiency and time economy improve. We describe EcoCount, which represents a development in environmental data recording procedure. EcoCount is a voice activated fully customizable digital count sheet that allows the investigator to continuously interact with a field of view during the data recording. Continuous viewing allows the palynologist the opportunity to remain engaged with the essential task, identification, for longer, making pollen counting more efficient and economical. EcoCount is a versatile software package that can be used to record a variety of environmental evidence and can be installed onto different computer platforms, making the adoption by users and laboratories simple and inexpensive. The user-friendly format of EcoCount allows any novice to be competent and functional in a very short time.

  18. RBC count

    Science.gov (United States)

    ... by kidney disease) RBC destruction ( hemolysis ) due to transfusion, blood vessel injury, or other cause Leukemia Malnutrition Bone ... slight risk any time the skin is broken) Alternative Names Erythrocyte count; Red blood cell count; Anemia - RBC count Images Blood test ...

  19. Rising from the ashes: Changes in salmonid fish assemblages after 30 months of the Puyehue-Cordon Caulle volcanic eruption.

    Science.gov (United States)

    Lallement, Mailén; Macchi, Patricio J; Vigliano, Pablo; Juarez, Santiago; Rechencq, Magalí; Baker, Matthew; Bouwes, Nicolaas; Crowl, Todd

    2016-01-15

    Events such as volcanic eruptions may act as disturbance agents modifying the landscape spatial diversity and increasing environmental instability. On June 4, 2011 the Puyehue-Cordon Caulle volcanic complex located on Chile (2236 m.a.s.l., 40° 02' 24" S- 70° 14' 26" W) experience a rift zone eruption ejecting during the first day 950 million metric tons into the atmosphere. Due to the westerly winds predominance, ash fell differentially upon 24 million ha of Patagonia Argentinean, been thicker deposits accumulated towards the West. In order to analyze changes on stream fish assemblages we studied seven streams 8, 19 and 30 months after the eruption along the ash deposition gradient, and compare those data to pre eruption ones. Habitat features and structure of the benthic macroinvertebrate food base of fish was studied. After the eruption, substantial environmental changes were observed in association with the large amount of ash fallout. In western sites, habitat loss due to ash accumulation, changes in the riparian zone and morphology of the main channels were observed. Turbidity was the water quality variable which reflected the most changes throughout time, with NTU values decreasing sharply from West to East sites. In west sites, increased Chironomid densities were recorded 8 months after the initial eruption as well as low EPT index values. These relationships were reversed in the less affected streams farther away from the volcano. Fish assemblages were greatly influenced both by habitat and macroinvertebrate changes. The eruption brought about an initial sharp decline in fish densities and the almost total loss of young of the year in the most western streams affecting recruitment. This effect diminished rapidly with distance from the emission center. Thirty months after the eruption, environmental changes are still occurring as a consequence of basin wide ash remobilization and transport.

  20. Counting statistics in low level radioactivity measurements fluctuating counting efficiency

    International Nuclear Information System (INIS)

    Pazdur, M.F.

    1976-01-01

    A divergence between the probability distribution of the number of nuclear disintegrations and the number of observed counts, caused by counting efficiency fluctuation, is discussed. The negative binominal distribution is proposed to describe the probability distribution of the number of counts, instead of Poisson distribution, which is assumed to hold for the number of nuclear disintegrations only. From actual measurements the r.m.s. amplitude of counting efficiency fluctuation is estimated. Some consequences of counting efficiency fluctuation are investigated and the corresponding formulae are derived: (1) for detection limit as a function of the number of partial measurements and the relative amplitude of counting efficiency fluctuation, and (2) for optimum allocation of the number of partial measurements between sample and background. (author)

  1. Determining random counts in liquid scintillation counting

    International Nuclear Information System (INIS)

    Horrocks, D.L.

    1979-01-01

    During measurements involving coincidence counting techniques, errors can arise due to the detection of chance or random coincidences in the multiple detectors used. A method and the electronic circuits necessary are here described for eliminating this source of error in liquid scintillation detectors used in coincidence counting. (UK)

  2. Radiation counting statistics

    Energy Technology Data Exchange (ETDEWEB)

    Suh, M. Y.; Jee, K. Y.; Park, K. K.; Park, Y. J.; Kim, W. H

    1999-08-01

    This report is intended to describe the statistical methods necessary to design and conduct radiation counting experiments and evaluate the data from the experiment. The methods are described for the evaluation of the stability of a counting system and the estimation of the precision of counting data by application of probability distribution models. The methods for the determination of the uncertainty of the results calculated from the number of counts, as well as various statistical methods for the reduction of counting error are also described. (Author). 11 refs., 8 tabs., 8 figs.

  3. Radiation counting statistics

    Energy Technology Data Exchange (ETDEWEB)

    Suh, M. Y.; Jee, K. Y.; Park, K. K. [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-08-01

    This report is intended to describe the statistical methods necessary to design and conduct radiation counting experiments and evaluate the data from the experiments. The methods are described for the evaluation of the stability of a counting system and the estimation of the precision of counting data by application of probability distribution models. The methods for the determination of the uncertainty of the results calculated from the number of counts, as well as various statistical methods for the reduction of counting error are also described. 11 refs., 6 figs., 8 tabs. (Author)

  4. Radiation counting statistics

    International Nuclear Information System (INIS)

    Suh, M. Y.; Jee, K. Y.; Park, K. K.; Park, Y. J.; Kim, W. H.

    1999-08-01

    This report is intended to describe the statistical methods necessary to design and conduct radiation counting experiments and evaluate the data from the experiment. The methods are described for the evaluation of the stability of a counting system and the estimation of the precision of counting data by application of probability distribution models. The methods for the determination of the uncertainty of the results calculated from the number of counts, as well as various statistical methods for the reduction of counting error are also described. (Author). 11 refs., 8 tabs., 8 figs

  5. Tower counts

    Science.gov (United States)

    Woody, Carol Ann; Johnson, D.H.; Shrier, Brianna M.; O'Neal, Jennifer S.; Knutzen, John A.; Augerot, Xanthippe; O'Neal, Thomas A.; Pearsons, Todd N.

    2007-01-01

    Counting towers provide an accurate, low-cost, low-maintenance, low-technology, and easily mobilized escapement estimation program compared to other methods (e.g., weirs, hydroacoustics, mark-recapture, and aerial surveys) (Thompson 1962; Siebel 1967; Cousens et al. 1982; Symons and Waldichuk 1984; Anderson 2000; Alaska Department of Fish and Game 2003). Counting tower data has been found to be consistent with that of digital video counts (Edwards 2005). Counting towers do not interfere with natural fish migration patterns, nor are fish handled or stressed; however, their use is generally limited to clear rivers that meet specific site selection criteria. The data provided by counting tower sampling allow fishery managers to determine reproductive population size, estimate total return (escapement + catch) and its uncertainty, evaluate population productivity and trends, set harvest rates, determine spawning escapement goals, and forecast future returns (Alaska Department of Fish and Game 1974-2000 and 1975-2004). The number of spawning fish is determined by subtracting subsistence, sport-caught fish, and prespawn mortality from the total estimated escapement. The methods outlined in this protocol for tower counts can be used to provide reasonable estimates ( plus or minus 6%-10%) of reproductive salmon population size and run timing in clear rivers. 

  6. Counting carbohydrates

    Science.gov (United States)

    Carb counting; Carbohydrate-controlled diet; Diabetic diet; Diabetes-counting carbohydrates ... Many foods contain carbohydrates (carbs), including: Fruit and fruit juice Cereal, bread, pasta, and rice Milk and milk products, soy milk Beans, legumes, ...

  7. Repeatability of differential goat bulk milk culture and associations with somatic cell count, total bacterial count, and standard plate count

    OpenAIRE

    Koop, G.; Dik, N.; Nielen, M.; Lipman, L.J.A.

    2010-01-01

    The aims of this study were to assess how different bacterial groups in bulk milk are related to bulk milk somatic cell count (SCC), bulk milk total bacterial count (TBC), and bulk milk standard plate count (SPC) and to measure the repeatability of bulk milk culturing. On 53 Dutch dairy goat farms, 3 bulk milk samples were collected at intervals of 2 wk. The samples were cultured for SPC, coliform count, and staphylococcal count and for the presence of Staphylococcus aureus. Furthermore, SCC ...

  8. Standardization of 241Am by digital coincidence counting, liquid scintillation counting and defined solid angle counting

    International Nuclear Information System (INIS)

    Balpardo, C.; Capoulat, M.E.; Rodrigues, D.; Arenillas, P.

    2010-01-01

    The nuclide 241 Am decays by alpha emission to 237 Np. Most of the decays (84.6%) populate the excited level of 237 Np with energy of 59.54 keV. Digital coincidence counting was applied to standardize a solution of 241 Am by alpha-gamma coincidence counting with efficiency extrapolation. Electronic discrimination was implemented with a pressurized proportional counter and the results were compared with two other independent techniques: Liquid scintillation counting using the logical sum of double coincidences in a TDCR array and defined solid angle counting taking into account activity inhomogeneity in the active deposit. The results show consistency between the three methods within a limit of a 0.3%. An ampoule of this solution will be sent to the International Reference System (SIR) during 2009. Uncertainties were analysed and compared in detail for the three applied methods.

  9. Benjamin Thompson, Count Rumford Count Rumford on the nature of heat

    CERN Document Server

    Brown, Sanborn C

    1967-01-01

    Men of Physics: Benjamin Thompson - Count Rumford: Count Rumford on the Nature of Heat covers the significant contributions of Count Rumford in the fields of physics. Count Rumford was born with the name Benjamin Thompson on March 23, 1753, in Woburn, Massachusetts. This book is composed of two parts encompassing 11 chapters, and begins with a presentation of Benjamin Thompson's biography and his interest in physics, particularly as an advocate of an """"anti-caloric"""" theory of heat. The subsequent chapters are devoted to his many discoveries that profoundly affected the physical thought

  10. Counting cormorants

    DEFF Research Database (Denmark)

    Bregnballe, Thomas; Carss, David N; Lorentsen, Svein-Håkon

    2013-01-01

    This chapter focuses on Cormorant population counts for both summer (i.e. breeding) and winter (i.e. migration, winter roosts) seasons. It also explains differences in the data collected from undertaking ‘day’ versus ‘roost’ counts, gives some definitions of the term ‘numbers’, and presents two...

  11. Short communication: Repeatability of differential goat bulk milk culture and associations with somatic cell count, total bacterial count, and standard plate count.

    Science.gov (United States)

    Koop, G; Dik, N; Nielen, M; Lipman, L J A

    2010-06-01

    The aims of this study were to assess how different bacterial groups in bulk milk are related to bulk milk somatic cell count (SCC), bulk milk total bacterial count (TBC), and bulk milk standard plate count (SPC) and to measure the repeatability of bulk milk culturing. On 53 Dutch dairy goat farms, 3 bulk milk samples were collected at intervals of 2 wk. The samples were cultured for SPC, coliform count, and staphylococcal count and for the presence of Staphylococcus aureus. Furthermore, SCC (Fossomatic 5000, Foss, Hillerød, Denmark) and TBC (BactoScan FC 150, Foss) were measured. Staphylococcal count was correlated to SCC (r=0.40), TBC (r=0.51), and SPC (r=0.53). Coliform count was correlated to TBC (r=0.33), but not to any of the other variables. Staphylococcus aureus did not correlate to SCC. The contribution of the staphylococcal count to the SPC was 31%, whereas the coliform count comprised only 1% of the SPC. The agreement of the repeated measurements was low. This study indicates that staphylococci in goat bulk milk are related to SCC and make a significant contribution to SPC. Because of the high variation in bacterial counts, repeated sampling is necessary to draw valid conclusions from bulk milk culturing. 2010 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  12. Repeatability of differential goat bulk milk culture and associations with somatic cell count, total bacterial count, and standard plate count

    NARCIS (Netherlands)

    Koop, G.; Dik, N.; Nielen, M.; Lipman, L.J.A.

    2010-01-01

    The aims of this study were to assess how different bacterial groups in bulk milk are related to bulk milk somatic cell count (SCC), bulk milk total bacterial count (TBC), and bulk milk standard plate count (SPC) and to measure the repeatability of bulk milk culturing. On 53 Dutch dairy goat farms,

  13. Standardization of {sup 241}Am by digital coincidence counting, liquid scintillation counting and defined solid angle counting

    Energy Technology Data Exchange (ETDEWEB)

    Balpardo, C., E-mail: balpardo@cae.cnea.gov.a [Laboratorio de Metrologia de Radioisotopos, CNEA, Buenos Aires (Argentina); Capoulat, M.E.; Rodrigues, D.; Arenillas, P. [Laboratorio de Metrologia de Radioisotopos, CNEA, Buenos Aires (Argentina)

    2010-07-15

    The nuclide {sup 241}Am decays by alpha emission to {sup 237}Np. Most of the decays (84.6%) populate the excited level of {sup 237}Np with energy of 59.54 keV. Digital coincidence counting was applied to standardize a solution of {sup 241}Am by alpha-gamma coincidence counting with efficiency extrapolation. Electronic discrimination was implemented with a pressurized proportional counter and the results were compared with two other independent techniques: Liquid scintillation counting using the logical sum of double coincidences in a TDCR array and defined solid angle counting taking into account activity inhomogeneity in the active deposit. The results show consistency between the three methods within a limit of a 0.3%. An ampoule of this solution will be sent to the International Reference System (SIR) during 2009. Uncertainties were analysed and compared in detail for the three applied methods.

  14. Clean Hands Count

    Medline Plus

    Full Text Available ... Like this video? Sign in to make your opinion count. Sign in 131 2 Don't like this video? Sign in to make your opinion count. Sign in 3 Loading... Loading... Transcript The ...

  15. Noun Countability; Count Nouns and Non-count Nouns, What are the Syntactic Differences Between them?

    Directory of Open Access Journals (Sweden)

    Azhar A. Alkazwini

    2016-11-01

    Full Text Available Words that function as the subjects of verbs, objects of verbs or prepositions and which can have a plural form and possessive ending are known as nouns. They are described as referring to persons, places, things, states, or qualities and might also be used as an attributive modifier. In this paper, classes and subclasses of nouns shall be presented, then, noun countability branching into count and non-count nous shall be discussed. A number of present examples illustrating differences between count and non-count nouns and this includes determiner-head-co-occurrence restrictions of number, subject-verb agreement, in addition to some exceptions to this agreement rule shall be discussed. Also, the lexically inherent number in nouns and how inherently plural nouns are classified in terms of (+/- count are illustrated. This research will discuss partitive construction of count and non-count nouns, nouns as attributive modifier and, finally, conclude with the fact that there are syntactic difference between count and non-count in the English Language.

  16. Clean Hands Count

    Medline Plus

    Full Text Available ... starting stop Loading... Watch Queue Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with ... ads? Get YouTube Red. Working... Not now Try it free Find out why Close Clean Hands Count ...

  17. Count-to-count time interval distribution analysis in a fast reactor

    International Nuclear Information System (INIS)

    Perez-Navarro Gomez, A.

    1973-01-01

    The most important kinetic parameters have been measured at the zero power fast reactor CORAL-I by means of the reactor noise analysis in the time domain, using measurements of the count-to-count time intervals. (Author) 69 refs

  18. The effect of volume and quenching on estimation of counting efficiencies in liquid scintillation counting

    International Nuclear Information System (INIS)

    Knoche, H.W.; Parkhurst, A.M.; Tam, S.W.

    1979-01-01

    The effect of volume on the liquid scintillation counting performance of 14 C-samples has been investigated. A decrease in counting efficiency was observed for samples with volumes below about 6 ml and those above about 18 ml when unquenched samples were assayed. Two quench-correction methods, sample channels ratio and external standard channels ratio, and three different liquid scintillation counters, were used in an investigation to determine the magnitude of the error in predicting counting efficiencies when small volume samples (2 ml) with different levels of quenching were assayed. The 2 ml samples exhibited slightly greater standard deviations of the difference between predicted and determined counting efficiencies than did 15 ml samples. Nevertheless, the magnitude of the errors indicate that if the sample channels ratio method of quench correction is employed, 2 ml samples may be counted in conventional counting vials with little loss in counting precision. (author)

  19. TasselNet: counting maize tassels in the wild via local counts regression network.

    Science.gov (United States)

    Lu, Hao; Cao, Zhiguo; Xiao, Yang; Zhuang, Bohan; Shen, Chunhua

    2017-01-01

    Accurately counting maize tassels is important for monitoring the growth status of maize plants. This tedious task, however, is still mainly done by manual efforts. In the context of modern plant phenotyping, automating this task is required to meet the need of large-scale analysis of genotype and phenotype. In recent years, computer vision technologies have experienced a significant breakthrough due to the emergence of large-scale datasets and increased computational resources. Naturally image-based approaches have also received much attention in plant-related studies. Yet a fact is that most image-based systems for plant phenotyping are deployed under controlled laboratory environment. When transferring the application scenario to unconstrained in-field conditions, intrinsic and extrinsic variations in the wild pose great challenges for accurate counting of maize tassels, which goes beyond the ability of conventional image processing techniques. This calls for further robust computer vision approaches to address in-field variations. This paper studies the in-field counting problem of maize tassels. To our knowledge, this is the first time that a plant-related counting problem is considered using computer vision technologies under unconstrained field-based environment. With 361 field images collected in four experimental fields across China between 2010 and 2015 and corresponding manually-labelled dotted annotations, a novel Maize Tassels Counting ( MTC ) dataset is created and will be released with this paper. To alleviate the in-field challenges, a deep convolutional neural network-based approach termed TasselNet is proposed. TasselNet can achieve good adaptability to in-field variations via modelling the local visual characteristics of field images and regressing the local counts of maize tassels. Extensive results on the MTC dataset demonstrate that TasselNet outperforms other state-of-the-art approaches by large margins and achieves the overall best counting

  20. TasselNet: counting maize tassels in the wild via local counts regression network

    Directory of Open Access Journals (Sweden)

    Hao Lu

    2017-11-01

    Full Text Available Abstract Background Accurately counting maize tassels is important for monitoring the growth status of maize plants. This tedious task, however, is still mainly done by manual efforts. In the context of modern plant phenotyping, automating this task is required to meet the need of large-scale analysis of genotype and phenotype. In recent years, computer vision technologies have experienced a significant breakthrough due to the emergence of large-scale datasets and increased computational resources. Naturally image-based approaches have also received much attention in plant-related studies. Yet a fact is that most image-based systems for plant phenotyping are deployed under controlled laboratory environment. When transferring the application scenario to unconstrained in-field conditions, intrinsic and extrinsic variations in the wild pose great challenges for accurate counting of maize tassels, which goes beyond the ability of conventional image processing techniques. This calls for further robust computer vision approaches to address in-field variations. Results This paper studies the in-field counting problem of maize tassels. To our knowledge, this is the first time that a plant-related counting problem is considered using computer vision technologies under unconstrained field-based environment. With 361 field images collected in four experimental fields across China between 2010 and 2015 and corresponding manually-labelled dotted annotations, a novel Maize Tassels Counting (MTC dataset is created and will be released with this paper. To alleviate the in-field challenges, a deep convolutional neural network-based approach termed TasselNet is proposed. TasselNet can achieve good adaptability to in-field variations via modelling the local visual characteristics of field images and regressing the local counts of maize tassels. Extensive results on the MTC dataset demonstrate that TasselNet outperforms other state-of-the-art approaches by large

  1. Isospectral discrete and quantum graphs with the same flip counts and nodal counts

    Science.gov (United States)

    Juul, Jonas S.; Joyner, Christopher H.

    2018-06-01

    The existence of non-isomorphic graphs which share the same Laplace spectrum (to be referred to as isospectral graphs) leads naturally to the following question: what additional information is required in order to resolve isospectral graphs? It was suggested by Band, Shapira and Smilansky that this might be achieved by either counting the number of nodal domains or the number of times the eigenfunctions change sign (the so-called flip count) (Band et al 2006 J. Phys. A: Math. Gen. 39 13999–4014 Band and Smilansky 2007 Eur. Phys. J. Spec. Top. 145 171–9). Recent examples of (discrete) isospectral graphs with the same flip count and nodal count have been constructed by Ammann by utilising Godsil–McKay switching (Ammann private communication). Here, we provide a simple alternative mechanism that produces systematic examples of both discrete and quantum isospectral graphs with the same flip and nodal counts.

  2. Counting It Twice.

    Science.gov (United States)

    Schattschneider, Doris

    1991-01-01

    Provided are examples from many domains of mathematics that illustrate the Fubini Principle in its discrete version: the value of a summation over a rectangular array is independent of the order of summation. Included are: counting using partitions as in proof by pictures, combinatorial arguments, indirect counting as in the inclusion-exclusion…

  3. Low White Blood Cell Count

    Science.gov (United States)

    Symptoms Low white blood cell count By Mayo Clinic Staff A low white blood cell count (leukopenia) is a decrease ... of white blood cell (neutrophil). The definition of low white blood cell count varies from one medical ...

  4. Hanford whole body counting manual

    International Nuclear Information System (INIS)

    Palmer, H.E.; Brim, C.P.; Rieksts, G.A.; Rhoads, M.C.

    1987-05-01

    This document, a reprint of the Whole Body Counting Manual, was compiled to train personnel, document operation procedures, and outline quality assurance procedures. The current manual contains information on: the location, availability, and scope of services of Hanford's whole body counting facilities; the administrative aspect of the whole body counting operation; Hanford's whole body counting facilities; the step-by-step procedure involved in the different types of in vivo measurements; the detectors, preamplifiers and amplifiers, and spectroscopy equipment; the quality assurance aspect of equipment calibration and recordkeeping; data processing, record storage, results verification, report preparation, count summaries, and unit cost accounting; and the topics of minimum detectable amount and measurement accuracy and precision. 12 refs., 13 tabs

  5. CalCOFI Egg Counts

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish egg counts and standardized counts for eggs captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets], and...

  6. Count-doubling time safety circuit

    International Nuclear Information System (INIS)

    Keefe, D.J.; McDowell, W.P.; Rusch, G.K.

    1981-01-01

    There is provided a nuclear reactor count-factor-increase time monitoring circuit which includes a pulse-type neutron detector, and means for counting the number of detected pulses during specific time periods. Counts are compared and the comparison is utilized to develop a reactor scram signal, if necessary

  7. Count-doubling time safety circuit

    Science.gov (United States)

    Rusch, Gordon K.; Keefe, Donald J.; McDowell, William P.

    1981-01-01

    There is provided a nuclear reactor count-factor-increase time monitoring circuit which includes a pulse-type neutron detector, and means for counting the number of detected pulses during specific time periods. Counts are compared and the comparison is utilized to develop a reactor scram signal, if necessary.

  8. The Big Pumpkin Count.

    Science.gov (United States)

    Coplestone-Loomis, Lenny

    1981-01-01

    Pumpkin seeds are counted after students convert pumpkins to jack-o-lanterns. Among the activities involved, pupils learn to count by 10s, make estimates, and to construct a visual representation of 1,000. (MP)

  9. Galaxy number counts: Pt. 2

    International Nuclear Information System (INIS)

    Metcalfe, N.; Shanks, T.; Fong, R.; Jones, L.R.

    1991-01-01

    Using the Prime Focus CCD Camera at the Isaac Newton Telescope we have determined the form of the B and R galaxy number-magnitude count relations in 12 independent fields for 21 m ccd m and 19 m ccd m 5. The average galaxy count relations lie in the middle of the wide range previously encompassed by photographic data. The field-to-field variation of the counts is small enough to define the faint (B m 5) galaxy count to ±10 per cent and this variation is consistent with that expected from galaxy clustering considerations. Our new data confirm that the B, and also the R, galaxy counts show evidence for strong galaxy luminosity evolution, and that the majority of the evolving galaxies are of moderately blue colour. (author)

  10. Counting statistics in radioactivity measurements

    International Nuclear Information System (INIS)

    Martin, J.

    1975-01-01

    The application of statistical methods to radioactivity measurement problems is analyzed in several chapters devoted successively to: the statistical nature of radioactivity counts; the application to radioactive counting of two theoretical probability distributions, Poisson's distribution law and the Laplace-Gauss law; true counting laws; corrections related to the nature of the apparatus; statistical techniques in gamma spectrometry [fr

  11. Correlation between total lymphocyte count, hemoglobin, hematocrit and CD4 count in HIV patients in Nigeria.

    Science.gov (United States)

    Emuchay, Charles Iheanyichi; Okeniyi, Shemaiah Olufemi; Okeniyi, Joshua Olusegun

    2014-04-01

    The expensive and technology limited setting of CD4 count testing is a major setback to the initiation of HAART in a resource limited country like Nigeria. Simple and inexpensive tools such as Hemoglobin (Hb) measurement and Total Lymphocyte Count (TLC) are recommended as substitute marker. In order to assess the correlations of these parameters with CD4 count, 100 "apparently healthy" male volunteers tested HIV positive aged ≥ 20 years but ≤ 40 years were recruited and from whom Hb, Hct, TLC and CD4 count were obtained. The correlation coefficients, R, the Nash-Sutcliffe Coefficient of Efficiency (CoE) and the p-values of the ANOVA model of Hb, Hct and TLC with CD4 count were assessed. The assessments show that there is no significant relationship of any of these parameters with CD4 count and the correlation coefficients are very weak. This study shows that Hb, Hct and TLC cannot be substitute for CD4 count as this might lead to certain individuals' deprivation of required treatment.

  12. It counts who counts: an experimental evaluation of the importance of observer effects on spotlight count estimates

    DEFF Research Database (Denmark)

    Sunde, Peter; Jessen, Lonnie

    2013-01-01

    observers with respect to their ability to detect and estimate distance to realistic animal silhouettes at different distances. Detection probabilities were higher for observers experienced in spotlighting mammals than for inexperienced observers, higher for observers with a hunting background compared...... with non-hunters and decreased as function of age but were independent of sex or educational background. If observer-specific detection probabilities were applied to real counting routes, point count estimates from inexperienced observers without a hunting background would only be 43 % (95 % CI, 39...

  13. You can count on the motor cortex: Finger counting habits modulate motor cortex activation evoked by numbers

    Science.gov (United States)

    Tschentscher, Nadja; Hauk, Olaf; Fischer, Martin H.; Pulvermüller, Friedemann

    2012-01-01

    The embodied cognition framework suggests that neural systems for perception and action are engaged during higher cognitive processes. In an event-related fMRI study, we tested this claim for the abstract domain of numerical symbol processing: is the human cortical motor system part of the representation of numbers, and is organization of numerical knowledge influenced by individual finger counting habits? Developmental studies suggest a link between numerals and finger counting habits due to the acquisition of numerical skills through finger counting in childhood. In the present study, digits 1 to 9 and the corresponding number words were presented visually to adults with different finger counting habits, i.e. left- and right-starters who reported that they usually start counting small numbers with their left and right hand, respectively. Despite the absence of overt hand movements, the hemisphere contralateral to the hand used for counting small numbers was activated when small numbers were presented. The correspondence between finger counting habits and hemispheric motor activation is consistent with an intrinsic functional link between finger counting and number processing. PMID:22133748

  14. Total lymphocyte count and subpopulation lymphocyte counts in relation to dietary intake and nutritional status of peritoneal dialysis patients.

    Science.gov (United States)

    Grzegorzewska, Alicja E; Leander, Magdalena

    2005-01-01

    Dietary deficiency causes abnormalities in circulating lymphocyte counts. For the present paper, we evaluated correlations between total and subpopulation lymphocyte counts (TLC, SLCs) and parameters of nutrition in peritoneal dialysis (PD) patients. Studies were carried out in 55 patients treated with PD for 22.2 +/- 11.4 months. Parameters of nutritional status included total body mass, lean body mass (LBM), body mass index (BMI), and laboratory indices [total protein, albumin, iron, ferritin, and total iron binding capacity (TIBC)]. The SLCs were evaluated using flow cytometry. Positive correlations were seen between TLC and dietary intake of niacin; TLC and CD8 and CD16+56 counts and energy delivered from protein; CD4 count and beta-carotene and monounsaturated fatty acids 17:1 intake; and CD19 count and potassium, copper, vitamin A, and beta-carotene intake. Anorexia negatively influenced CD19 count. Serum albumin showed correlations with CD4 and CD19 counts, and LBM with CD19 count. A higher CD19 count was connected with a higher red blood cell count, hemoglobin, and hematocrit. Correlations were observed between TIBC and TLC and CD3 and CD8 counts, and between serum Fe and TLC and CD3 and CD4 counts. Patients with a higher CD19 count showed a better clinical-laboratory score, especially less weakness. Patients with a higher CD4 count had less expressed insomnia. Quantities of ingested vitamins and minerals influence lymphocyte counts in the peripheral blood of PD patients. Evaluation of TLC and SLCs is helpful in monitoring the effectiveness of nutrition in these patients.

  15. Heterogeneous counting on filter support media

    International Nuclear Information System (INIS)

    Long, E.; Kohler, V.; Kelly, M.J.

    1976-01-01

    Many investigators in the biomedical research area have used filter paper as the support for radioactive samples. This means that a heterogeneous counting of sample sometimes results. The count rate of a sample on a filter will be affected by positioning, degree of dryness, sample application procedure, the type of filter, and the type of cocktail used. Positioning of the filter (up or down) in the counting vial can cause a variation of 35% or more when counting tritiated samples on filter paper. Samples of varying degrees of dryness when added to the counting cocktail can cause nonreproducible counts if handled improperly. Count rates starting at 2400 CPM initially can become 10,000 CPM in 24 hours for 3 H-DNA (deoxyribonucleic acid) samples dried on standard cellulose acetate membrane filters. Data on cellulose nitrate filters show a similar trend. Sample application procedures in which the sample is applied to the filter in a small spot or on a large amount of the surface area can cause nonreproducible or very low counting rates. A tritiated DNA sample, when applied topically, gives a count rate of 4,000 CPM. When the sample is spread over the whole filter, 13,400 CPM are obtained with a much better coefficient of variation (5% versus 20%). Adding protein carrier (bovine serum albumin-BSA) to the sample to trap more of the tritiated DNA on the filter during the filtration process causes a serious beta absorption problem. Count rates which are one-fourth the count rate applied to the filter are obtained on calibrated runs. Many of the problems encountered can be alleviated by a proper choice of filter and the use of a liquid scintillation cocktail which dissolves the filter. Filter-Solv has been used to dissolve cellulose nitrate filters and filters which are a combination of cellulose nitrate and cellulose acetate. Count rates obtained for these dissolved samples are very reproducible and highly efficient

  16. LAWRENCE RADIATION LABORATORY COUNTING HANDBOOK

    Energy Technology Data Exchange (ETDEWEB)

    Group, Nuclear Instrumentation

    1966-10-01

    The Counting Handbook is a compilation of operational techniques and performance specifications on counting equipment in use at the Lawrence Radiation Laboratory, Berkeley. Counting notes have been written from the viewpoint of the user rather than that of the designer or maintenance man. The only maintenance instructions that have been included are those that can easily be performed by the experimenter to assure that the equipment is operating properly.

  17. The Kruskal Count

    OpenAIRE

    Lagarias, Jeffrey C.; Rains, Eric; Vanderbei, Robert J.

    2001-01-01

    The Kruskal Count is a card trick invented by Martin J. Kruskal in which a magician "guesses" a card selected by a subject according to a certain counting procedure. With high probability the magician can correctly "guess" the card. The success of the trick is based on a mathematical principle related to coupling methods for Markov chains. This paper analyzes in detail two simplified variants of the trick and estimates the probability of success. The model predictions are compared with simula...

  18. SPERM COUNT DISTRIBUTIONS IN FERTILE MEN

    Science.gov (United States)

    Sperm concentration and count are often used as indicators of environmental impacts on male reproductive health. Existing clinical databases may be biased towards subfertile men with low sperm counts and less is known about expected sperm count distributions in cohorts of fertil...

  19. Bayesian analysis of energy and count rate data for detection of low count rate radioactive sources.

    Science.gov (United States)

    Klumpp, John; Brandl, Alexander

    2015-03-01

    A particle counting and detection system is proposed that searches for elevated count rates in multiple energy regions simultaneously. The system analyzes time-interval data (e.g., time between counts), as this was shown to be a more sensitive technique for detecting low count rate sources compared to analyzing counts per unit interval (Luo et al. 2013). Two distinct versions of the detection system are developed. The first is intended for situations in which the sample is fixed and can be measured for an unlimited amount of time. The second version is intended to detect sources that are physically moving relative to the detector, such as a truck moving past a fixed roadside detector or a waste storage facility under an airplane. In both cases, the detection system is expected to be active indefinitely; i.e., it is an online detection system. Both versions of the multi-energy detection systems are compared to their respective gross count rate detection systems in terms of Type I and Type II error rates and sensitivity.

  20. Total bacterial count and somatic cell count in refrigerated raw milk stored in communal tanks

    Directory of Open Access Journals (Sweden)

    Edmar da Costa Alves

    2014-09-01

    Full Text Available The current industry demand for dairy products with extended shelf life has resulted in new challenges for milk quality maintenance. The processing of milk with high bacterial counts compromises the quality and performance of industrial products. The study aimed to evaluate the total bacteria counts (TBC and somatic cell count (SCC in 768 samples of refrigerated raw milk, from 32 communal tanks. Samples were collected in the first quarter of 2010, 2011, 2012 and 2013 and analyzed by the Laboratory of Milk Quality - LQL. Results showed that 62.5%, 37.5%, 15.6% and 27.1% of the means for TBC in 2010, 2011, 2012 and 2013, respectively, were above the values established by legislation. However, we observed a significant reduction in the levels of total bacterial count (TBC in the studied periods. For somatic cell count, 100% of the means indicated values below 600.000 cells/mL, complying with the actual Brazilian legislation. The values found for the somatic cell count suggests the adoption of effective measures for the sanitary control of the herd. However, the results must be considered with caution as it highlights the need for quality improvements of the raw material until it achieves reliable results effectively.

  1. Rainflow counting revisited

    Energy Technology Data Exchange (ETDEWEB)

    Soeker, H [Deutsches Windenergie-Institut (Germany)

    1996-09-01

    As state of the art method the rainflow counting technique is presently applied everywhere in fatigue analysis. However, the author feels that the potential of the technique is not fully recognized in wind energy industries as it is used, most of the times, as a mere data reduction technique disregarding some of the inherent information of the rainflow counting results. The ideas described in the following aim at exploitation of this information and making it available for use in the design and verification process. (au)

  2. Radon counting statistics - a Monte Carlo investigation

    International Nuclear Information System (INIS)

    Scott, A.G.

    1996-01-01

    Radioactive decay is a Poisson process, and so the Coefficient of Variation (COV) of open-quotes nclose quotes counts of a single nuclide is usually estimated as 1/√n. This is only true if the count duration is much shorter than the half-life of the nuclide. At longer count durations, the COV is smaller than the Poisson estimate. Most radon measurement methods count the alpha decays of 222 Rn, plus the progeny 218 Po and 214 Po, and estimate the 222 Rn activity from the sum of the counts. At long count durations, the chain decay of these nuclides means that every 222 Rn decay must be followed by two other alpha decays. The total number of decays is open-quotes 3Nclose quotes, where N is the number of radon decays, and the true COV of the radon concentration estimate is 1/√(N), √3 larger than the Poisson total count estimate of 1/√3N. Most count periods are comparable to the half lives of the progeny, so the relationship between COV and count time is complex. A Monte-Carlo estimate of the ratio of true COV to Poisson estimate was carried out for a range of count periods from 1 min to 16 h and three common radon measurement methods: liquid scintillation, scintillation cell, and electrostatic precipitation of progeny. The Poisson approximation underestimates COV by less than 20% for count durations of less than 60 min

  3. Hanford whole body counting manual

    International Nuclear Information System (INIS)

    Palmer, H.E.; Rieksts, G.A.; Lynch, T.P.

    1990-06-01

    This document describes the Hanford Whole Body Counting Program as it is administered by Pacific Northwest Laboratory (PNL) in support of the US Department of Energy--Richland Operations Office (DOE-RL) and its Hanford contractors. Program services include providing in vivo measurements of internally deposited radioactivity in Hanford employees (or visitors). Specific chapters of this manual deal with the following subjects: program operational charter, authority, administration, and practices, including interpreting applicable DOE Orders, regulations, and guidance into criteria for in vivo measurement frequency, etc., for the plant-wide whole body counting services; state-of-the-art facilities and equipment used to provide the best in vivo measurement results possible for the approximately 11,000 measurements made annually; procedures for performing the various in vivo measurements at the Whole Body Counter (WBC) and related facilities including whole body counts; operation and maintenance of counting equipment, quality assurance provisions of the program, WBC data processing functions, statistical aspects of in vivo measurements, and whole body counting records and associated guidance documents. 16 refs., 48 figs., 22 tabs

  4. Platelet Count and Plateletcrit

    African Journals Online (AJOL)

    strated that neonates with late onset sepsis (bacteremia after 3 days of age) had a dramatic increase in MPV and. PDW18. We hypothesize that as the MPV and PDW increase and platelet count and PCT decrease in sick children, intui- tively, the ratio of MPV to PCT; MPV to Platelet count,. PDW to PCT, PDW to platelet ...

  5. An Adaptive Smoother for Counting Measurements

    International Nuclear Information System (INIS)

    Kondrasovs Vladimir; Coulon Romain; Normand Stephane

    2013-06-01

    Counting measurements associated with nuclear instruments are tricky to carry out due to the stochastic process of the radioactivity. Indeed events counting have to be processed and filtered in order to display a stable count rate value and to allow variations monitoring in the measured activity. Smoothers (as the moving average) are adjusted by a time constant defined as a compromise between stability and response time. A new approach has been developed and consists in improving the response time while maintaining count rate stability. It uses the combination of a smoother together with a detection filter. A memory of counting data is processed to calculate several count rate estimates using several integration times. These estimates are then sorted into the memory from short to long integration times. A measurement position, in terms of integration time, is then chosen into this memory after a detection test. An inhomogeneity into the Poisson counting process is detected by comparison between current position estimate and the other estimates contained into the memory in respect with the associated statistical variance calculated with homogeneous assumption. The measurement position (historical time) and the ability to forget an obsolete data or to keep in memory a useful data are managed using the detection test result. The proposed smoother is then an adaptive and a learning algorithm allowing an optimization of the response time while maintaining measurement counting stability and converging efficiently to the best counting estimate after an effective change in activity. This algorithm has also the specificity to be low recursive and thus easily embedded into DSP electronics based on FPGA or micro-controllers meeting 'real life' time requirements. (authors)

  6. Counting probe

    International Nuclear Information System (INIS)

    Matsumoto, Haruya; Kaya, Nobuyuki; Yuasa, Kazuhiro; Hayashi, Tomoaki

    1976-01-01

    Electron counting method has been devised and experimented for the purpose of measuring electron temperature and density, the most fundamental quantities to represent plasma conditions. Electron counting is a method to count the electrons in plasma directly by equipping a probe with the secondary electron multiplier. It has three advantages of adjustable sensitivity, high sensitivity of the secondary electron multiplier, and directional property. Sensitivity adjustment is performed by changing the size of collecting hole (pin hole) on the incident front of the multiplier. The probe is usable as a direct reading thermometer of electron temperature because it requires to collect very small amount of electrons, thus it doesn't disturb the surrounding plasma, and the narrow sweep width of the probe voltage is enough. Therefore it can measure anisotropy more sensitively than a Langmuir probe, and it can be used for very low density plasma. Though many problems remain on anisotropy, computer simulation has been carried out. Also it is planned to provide a Helmholtz coil in the vacuum chamber to eliminate the effect of earth magnetic field. In practical experiments, the measurement with a Langmuir probe and an emission probe mounted to the movable structure, the comparison with the results obtained in reverse magnetic field by using a Helmholtz coil, and the measurement of ionic sound wave are scheduled. (Wakatsuki, Y.)

  7. A mind you can count on: validating breath counting as a behavioral measure of mindfulness

    Directory of Open Access Journals (Sweden)

    Daniel B Levinson

    2014-10-01

    Full Text Available Mindfulness practice of present moment awareness promises many benefits, but has eluded rigorous behavioral measurement. To date, research has relied on self-reported mindfulness or heterogeneous mindfulness trainings to infer skillful mindfulness practice and its effects. In four independent studies with over 400 total participants, we present the first construct validation of a behavioral measure of mindfulness, breath counting. We found it was reliable, correlated with self-reported mindfulness, differentiated long-term meditators from age-matched controls, and was distinct from sustained attention and working memory measures. In addition, we employed breath counting to test the nomological network of mindfulness. As theorized, we found skill in breath counting associated with more meta-awareness, less mind wandering, better mood, and greater nonattachment (i.e. less attentional capture by distractors formerly paired with reward. We also found in a randomized online training study that 4 weeks of breath counting training improved mindfulness and decreased mind wandering relative to working memory training and no training controls. Together, these findings provide the first evidence for breath counting as a behavioral measure of mindfulness.

  8. Principles of correlation counting

    International Nuclear Information System (INIS)

    Mueller, J.W.

    1975-01-01

    A review is given of the various applications which have been made of correlation techniques in the field of nuclear physics, in particular for absolute counting. Whereas in most cases the usual coincidence method will be preferable for its simplicity, correlation counting may be the only possible approach in such cases where the two radiations of the cascade cannot be well separated or when there is a longliving intermediate state. The measurement of half-lives and of count rates of spurious pulses is also briefly discussed. The various experimental situations lead to different ways the correlation method is best applied (covariance technique with one or with two detectors, application of correlation functions, etc.). Formulae are given for some simple model cases, neglecting dead-time corrections

  9. Delta count-rate monitoring system

    International Nuclear Information System (INIS)

    Van Etten, D.; Olsen, W.A.

    1985-01-01

    A need for a more effective way to rapidly search for gamma-ray contamination over large areas led to the design and construction of a very sensitive gamma detection system. The delta count-rate monitoring system was installed in a four-wheel-drive van instrumented for environmental surveillance and accident response. The system consists of four main sections: (1) two scintillation detectors, (2) high-voltage power supply amplifier and single-channel analyzer, (3) delta count-rate monitor, and (4) count-rate meter and recorder. The van's 6.5-kW generator powers the standard nuclear instrument modular design system. The two detectors are mounted in the rear corners of the van and can be run singly or jointly. A solid-state bar-graph count-rate meter mounted on the dashboard can be read easily by both the driver and passenger. A solid-state strip chart recorder shows trends and provides a permanent record of the data. An audible alarm is sounded at the delta monitor and at the dashboard count-rate meter if a detected radiation level exceeds the set background level by a predetermined amount

  10. DC KIDS COUNT e-Databook Indicators

    Science.gov (United States)

    DC Action for Children, 2012

    2012-01-01

    This report presents indicators that are included in DC Action for Children's 2012 KIDS COUNT e-databook, their definitions and sources and the rationale for their selection. The indicators for DC KIDS COUNT represent a mix of traditional KIDS COUNT indicators of child well-being, such as the number of children living in poverty, and indicators of…

  11. In vivo counting of uranium

    International Nuclear Information System (INIS)

    Palmer, H.E.

    1985-03-01

    A state-of-the-art radiation detector system consisting of six individually mounted intrinsic germanium planar detectors, each 20 cm 2 by 13 mm thick, mounted together such that the angle of the whole system can be changed to match the slope of the chest of the person being counted, is described. The sensitivity of the system for counting uranium and plutonium in vivo and the precedures used in calibrating the system are also described. Some results of counts done on uranium mill workers are presented. 15 figs., 2 tabs

  12. Beach-ridge series in northern Peru: chronology, correlation, and relationship with major Late Holocene El Niño events

    Directory of Open Access Journals (Sweden)

    1993-01-01

    Full Text Available SÉRIES DE CORDONS LITTORAUX DANS LE NORD DU PÉROU: CHRONOLOGIE, CORRÉLATION ET RELATION AVEC DES ÉPISODES EL NIÑO INTENSES DE L'HOLOCÈNE SUPÉRIEUR. Les séquences de cordons littoraux observés à proximité de l'embouchure des principaux fleuves de la côte nord du Pérou (rios Santa, Chira et Piura pourraient être des témoins des événements El Niño les plus intenses de la seconde moitié de l' Holocène. Pour vérifier cette hypothèse, nous réexaminons les principaux traits des deux séquences de cordons préservés de part et d'autre de l'embouchure du rio Chira, et en particulier l'ensemble des âges radiocarbone disponibles. Les cordons de ces deux localités diffèrent notamment par le type de sédiment, leurs dimensions et leur forme. Néanmoins, dans les deux cas, les processus de formation impliquent des conditions météorologiques et océanographiques particulières qui caractérisent les épisodes El Niño les plus intenses. Les datations par radiocarbone de coquilles marines (soit incluses dans le sédiment des cordons, soit recouvrant ces derniers et de charbons d'origine anthropique suggèrent que les deux séquences sont contemporaines et couvrent les derniers 4 500 ans. Les cordons se seraient formés à des intervalles de temps de l'ordre de 100-600 ans. La comparaison géomorphologique des deux séries de cordons, ainsi que leur disposition géométrique et l'ensemble des données radiochronologiques conduisent à proposer une corrélation chronologique des deux séquences. Cette corrélation tend à confirmer que ces constructions littorales sont liées aux anomalies océan /climat les plus intenses de type El Niño qui se soient produites durant les derniers milliers d'années. SECUENCIAS DE CORDONES LITORALES EN EL NORTE DEL PERÚ: CRONOLOGÍA, CORRELACIÓN Y RELACIONES CON MAYORES EVENTOS EL NIÑO DEL HOLOCENO TARDÍO. Las secuencias de cordones litorales observadas cerca de la desembocadura de los mayores r

  13. Alpha scintillation radon counting

    International Nuclear Information System (INIS)

    Lucas, H.F. Jr.

    1977-01-01

    Radon counting chambers which utilize the alpha-scintillation properties of silver activated zinc sulfide are simple to construct, have a high efficiency, and, with proper design, may be relatively insensitive to variations in the pressure or purity of the counter filling. Chambers which were constructed from glass, metal, or plastic in a wide variety of shapes and sizes were evaluated for the accuracy and the precision of the radon counting. The principles affecting the alpha-scintillation radon counting chamber design and an analytic system suitable for a large scale study of the 222 Rn and 226 Ra content of either air or other environmental samples are described. Particular note is taken of those factors which affect the accuracy and the precision of the method for monitoring radioactivity around uranium mines

  14. Equivalence of truncated count mixture distributions and mixtures of truncated count distributions.

    Science.gov (United States)

    Böhning, Dankmar; Kuhnert, Ronny

    2006-12-01

    This article is about modeling count data with zero truncation. A parametric count density family is considered. The truncated mixture of densities from this family is different from the mixture of truncated densities from the same family. Whereas the former model is more natural to formulate and to interpret, the latter model is theoretically easier to treat. It is shown that for any mixing distribution leading to a truncated mixture, a (usually different) mixing distribution can be found so that the associated mixture of truncated densities equals the truncated mixture, and vice versa. This implies that the likelihood surfaces for both situations agree, and in this sense both models are equivalent. Zero-truncated count data models are used frequently in the capture-recapture setting to estimate population size, and it can be shown that the two Horvitz-Thompson estimators, associated with the two models, agree. In particular, it is possible to achieve strong results for mixtures of truncated Poisson densities, including reliable, global construction of the unique NPMLE (nonparametric maximum likelihood estimator) of the mixing distribution, implying a unique estimator for the population size. The benefit of these results lies in the fact that it is valid to work with the mixture of truncated count densities, which is less appealing for the practitioner but theoretically easier. Mixtures of truncated count densities form a convex linear model, for which a developed theory exists, including global maximum likelihood theory as well as algorithmic approaches. Once the problem has been solved in this class, it might readily be transformed back to the original problem by means of an explicitly given mapping. Applications of these ideas are given, particularly in the case of the truncated Poisson family.

  15. Blood Count Tests: MedlinePlus Health Topic

    Science.gov (United States)

    ... Spanish WBC count (Medical Encyclopedia) Also in Spanish Topic Image MedlinePlus Email Updates Get Blood Count Tests ... WBC count Show More Show Less Related Health Topics Bleeding Disorders Blood Laboratory Tests National Institutes of ...

  16. Evaluation of lactate, white blood cell count, neutrophil count, procalcitonin and immature granulocyte count as biomarkers for sepsis in emergency department patients.

    Science.gov (United States)

    Karon, Brad S; Tolan, Nicole V; Wockenfus, Amy M; Block, Darci R; Baumann, Nikola A; Bryant, Sandra C; Clements, Casey M

    2017-11-01

    Lactate, white blood cell (WBC) and neutrophil count, procalcitonin and immature granulocyte (IG) count were compared for the prediction of sepsis, and severe sepsis or septic shock, in patients presenting to the emergency department (ED). We prospectively enrolled 501 ED patients with a sepsis panel ordered for suspicion of sepsis. WBC, neutrophil, and IG counts were measured on a Sysmex XT-2000i analyzer. Lactate was measured by i-STAT, and procalcitonin by Brahms Kryptor. We classified patients as having sepsis using a simplification of the 1992 consensus conference sepsis definitions. Patients with sepsis were further classified as having severe sepsis or septic shock using established criteria. Univariate receiver operating characteristic (ROC) analysis was performed to determine odds ratio (OR), area under the ROC curve (AUC), and sensitivity/specificity at optimal cut-off for prediction of sepsis (vs. no sepsis), and prediction of severe sepsis or septic shock (vs. no sepsis). There were 267 patients without sepsis; and 234 with sepsis, including 35 patients with severe sepsis or septic shock. Lactate had the highest OR (1.44, 95th% CI 1.20-1.73) for the prediction of sepsis; while WBC, neutrophil count and percent (neutrophil/WBC) had OR>1.00 (psepsis or septic shock, with an odds ratio (95th% CI) of 2.70 (2.02-3.61) and AUC 0.89 (0.82-0.96). Traditional biomarkers (lactate, WBC, neutrophil count, procalcitonin, IG) have limited utility in the prediction of sepsis. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  17. Serum Copper Level Significantly Influences Platelet Count, Lymphocyte Count and Mean Cell Hemoglobin in Sickle Cell Anemia

    Directory of Open Access Journals (Sweden)

    Okocha Chide

    2015-12-01

    Full Text Available Background Changes in serum micro nutrients levels affect a number of critically important metabolic processes; these could potentially influence blood counts and ultimately disease presentation in patients with sickle cell anemia (SCA. Objectives To evaluate the influence of serum micro-nutrients levels; zinc, copper, selenium and magnesium on blood counts in steady state SCA patients. Methods A cross sectional study that involved 28 steady state adult SCA subjects. Seven milliliters (mls of blood was collected; 3 mls was for hemoglobin electrophoresis and full blood count determination while 4 mls was for measurement of serum micro nutrients levels, by the atomic absorption spectrophotometry. Correlation between serum micro-nutrient levels and blood counts was done by the Pearson’s linear regression. Ethical approval was obtained from the institutional review board and each participant gave informed consent. All data was analyzed by SPSS software version 20. Results There was a significant correlation between serum copper levels and mean cell hemoglobin (MCH, platelet and lymphocyte counts (r = 0.418; P = 0.02, r = -0.376; P = 0.04 and r = -0.383; P = 0.04, respectively. There were no significant correlations between serum levels of other micro nutrients (selenium, zinc and magnesium and blood counts. Conclusions Copper influences blood count in SCA patients probably by inducing red cell haemolysis, oxidant tissue damage and stimulating the immune system.

  18. Correction for decay during counting in gamma spectrometry

    International Nuclear Information System (INIS)

    Nir-El, Y.

    2013-01-01

    A basic result in gamma spectrometry is the count rate of a relevant peak. Correction for decay during counting and expressing the count rate at the beginning of the measurement can be done by a multiplicative factor that is derived from integrating the count rate over time. The counting time substituted in this factor must be the live time, whereas the use of the real-time is an error that underestimates the count rate by about the dead-time (DT) (in percentage). This error of underestimation of the count rate is corroborated in the measurement of a nuclide with a high DT. The present methodology is not applicable in systems that include a zero DT correction function. (authors)

  19. Interpretation of galaxy counts

    International Nuclear Information System (INIS)

    Tinsely, B.M.

    1980-01-01

    New models are presented for the interpretation of recent counts of galaxies to 24th magnitude, and predictions are shown to 28th magnitude for future comparison with data from the Space Telescope. The results supersede earlier, more schematic models by the author. Tyson and Jarvis found in their counts a ''local'' density enhancement at 17th magnitude, on comparison with the earlier models; the excess is no longer significant when a more realistic mixture of galaxy colors is used. Bruzual and Kron's conclusion that Kron's counts show evidence for evolution at faint magnitudes is confirmed, and it is predicted that some 23d magnitude galaxies have redshifts greater than unity. These may include spheroidal systems, elliptical galaxies, and the bulges of early-type spirals and S0's, seen during their primeval rapid star formation

  20. Total lymphocyte count as a substitute to cd4 count in management of hiv infected individuals in resource limited society

    International Nuclear Information System (INIS)

    Daud, M.Y.; Qazi, R.A.

    2015-01-01

    Pakistan is a resource limited society and gold standard parameters to monitor HIV disease activity are very costly. The objective of the study was to evaluate total lymphocyte count (TLC) as a surrogate to CD4 count to monitor disease activity in HIV/AIDS in resource limited society. Methods: This cross sectional study was carried out at HIV/AIDS treatment centre, Pakistan Institute of Medical Sciences (PIMS), Islamabad. A total of seven hundred and seventy four (774) HIV positive patients were enrolled in this study, and their CD4 count and total lymphocyte count were checked to find any correlation between the two by using Spearman ranked correlation coefficient. Results: The mean CD4 count was (434.30 ± 269.23), with minimum CD4 count of (9.00), and maximum of (1974.00). The mean total lymphocyte count (TLC) was (6764.0052 ± 2364.02) with minimum TLC (1200.00) and maximum TLC was (20200.00). Using the Pearson's correlation (r) there was a significant and positive correlation between TLC and CD4 count. (r2=0.127 and p=0.000) at 0.01 level. Conclusion: Our study showed a significant positive correlation between CD4 count and total lymphocyte count (TLC), so TLC can be used as a marker of disease activity in HIV infected patients. (author)

  1. A counting-card circuit based on PCI bus

    International Nuclear Information System (INIS)

    Shi Jing; Li Yong; Chinese Academy of Sciences, Lanzhou; Su Hong; Dong Chengfu; Li Xiaogang; Ma Xiaoli

    2004-01-01

    A counting-card circuit based on PCI bus that we developed recently used for advanced personal computer will be introduced in this paper briefly. The maximum count capacity of this counting-card is 10 9 -1, ranging from 0 to 999 999 999, the maximum counting time range, 1 x 10 6 s, can be set in 1 cycle, the maximum counting rate is 20 MHz for positive input. (authors)

  2. TU-FG-209-03: Exploring the Maximum Count Rate Capabilities of Photon Counting Arrays Based On Polycrystalline Silicon

    Energy Technology Data Exchange (ETDEWEB)

    Liang, A K; Koniczek, M; Antonuk, L E; El-Mohri, Y; Zhao, Q [University of Michigan, Ann Arbor, MI (United States)

    2016-06-15

    Purpose: Photon counting arrays (PCAs) offer several advantages over conventional, fluence-integrating x-ray imagers, such as improved contrast by means of energy windowing. For that reason, we are exploring the feasibility and performance of PCA pixel circuitry based on polycrystalline silicon. This material, unlike the crystalline silicon commonly used in photon counting detectors, lends itself toward the economic manufacture of radiation tolerant, monolithic large area (e.g., ∼43×43 cm2) devices. In this presentation, exploration of maximum count rate, a critical performance parameter for such devices, is reported. Methods: Count rate performance for a variety of pixel circuit designs was explored through detailed circuit simulations over a wide range of parameters (including pixel pitch and operating conditions) with the additional goal of preserving good energy resolution. The count rate simulations assume input events corresponding to a 72 kVp x-ray spectrum with 20 mm Al filtration interacting with a CZT detector at various input flux rates. Output count rates are determined at various photon energy threshold levels, and the percentage of counts lost (e.g., due to deadtime or pile-up) is calculated from the ratio of output to input counts. The energy resolution simulations involve thermal and flicker noise originating from each circuit element in a design. Results: Circuit designs compatible with pixel pitches ranging from 250 to 1000 µm that allow count rates over a megacount per second per pixel appear feasible. Such rates are expected to be suitable for radiographic and fluoroscopic imaging. Results for the analog front-end circuitry of the pixels show that acceptable energy resolution can also be achieved. Conclusion: PCAs created using polycrystalline silicon have the potential to offer monolithic large-area detectors with count rate performance comparable to those of crystalline silicon detectors. Further improvement through detailed circuit

  3. Recursive algorithms for phylogenetic tree counting.

    Science.gov (United States)

    Gavryushkina, Alexandra; Welch, David; Drummond, Alexei J

    2013-10-28

    In Bayesian phylogenetic inference we are interested in distributions over a space of trees. The number of trees in a tree space is an important characteristic of the space and is useful for specifying prior distributions. When all samples come from the same time point and no prior information available on divergence times, the tree counting problem is easy. However, when fossil evidence is used in the inference to constrain the tree or data are sampled serially, new tree spaces arise and counting the number of trees is more difficult. We describe an algorithm that is polynomial in the number of sampled individuals for counting of resolutions of a constraint tree assuming that the number of constraints is fixed. We generalise this algorithm to counting resolutions of a fully ranked constraint tree. We describe a quadratic algorithm for counting the number of possible fully ranked trees on n sampled individuals. We introduce a new type of tree, called a fully ranked tree with sampled ancestors, and describe a cubic time algorithm for counting the number of such trees on n sampled individuals. These algorithms should be employed for Bayesian Markov chain Monte Carlo inference when fossil data are included or data are serially sampled.

  4. Photon-counting image sensors

    CERN Document Server

    Teranishi, Nobukazu; Theuwissen, Albert; Stoppa, David; Charbon, Edoardo

    2017-01-01

    The field of photon-counting image sensors is advancing rapidly with the development of various solid-state image sensor technologies including single photon avalanche detectors (SPADs) and deep-sub-electron read noise CMOS image sensor pixels. This foundational platform technology will enable opportunities for new imaging modalities and instrumentation for science and industry, as well as new consumer applications. Papers discussing various photon-counting image sensor technologies and selected new applications are presented in this all-invited Special Issue.

  5. A Survey of Italian Physicians' Opinion about Stem Cells Research: What Doctors Prefer and What the Law Requires

    OpenAIRE

    Frati, Paola; Gulino, Matteo; Pacchiarotti, Arianna; D'Errico, Stefano; Sicuro, Lorella; Fineschi, Vittorio

    2014-01-01

    To evaluate the Italian physicians' knowledge/information level about the therapeutic potential of stem cells, the research choice between embryonic and cordonal stem cells, and the preference between autologous and heterologous storage of cordonal stem cells, we performed a national survey. The questionnaire—distributed to 3361 physicians—involved physicians of different religious orientations and of different medical specialities. Most of the physicians involved (67%) were Catholics, and th...

  6. Platelet counting using the Coulter electronic counter.

    Science.gov (United States)

    Eggleton, M J; Sharp, A A

    1963-03-01

    A method for counting platelets in dilutions of platelet-rich plasm using the Coulter electronic counter is described.(1) The results obtained show that such platelet counts are at least as accurate as the best methods of visual counting. The various technical difficulties encountered are discussed.

  7. Automated uranium analysis by delayed-neutron counting

    International Nuclear Information System (INIS)

    Kunzendorf, H.; Loevborg, L.; Christiansen, E.M.

    1980-10-01

    Automated uranium analysis by fission-induced delayed-neutron counting is described. A short description is given of the instrumentation including transfer system, process control, irradiation and counting sites, and computer operations. Characteristic parameters of the facility (sample preparations, background, and standards) are discussed. A sensitivity of 817 +- 22 counts per 10 -6 g U is found using irradiation, delay, and counting times of 20 s, 5 s, and 10 s, respectively. Presicion is generally less than 1% for normal geological samples. Critical level and detection limits for 7.5 g samples are 8 and 16 ppb, respectively. The importance of some physical and elemental interferences are outlined. Dead-time corrections of measured count rates are necessary and a polynomical expression is used for count rates up to 10 5 . The presence of rare earth elements is regarded as the most important elemental interference. A typical application is given and other areas of application are described. (auther)

  8. Count rate effect in proportional counters

    International Nuclear Information System (INIS)

    Bednarek, B.

    1980-01-01

    A new concept is presented explaining changes in spectrometric parameters of proportional counters which occur due to varying count rate. The basic feature of this concept is that the gas gain of the counter remains constant in a wide range of count rate and that the decrease in the pulse amplitude and the detorioration of the energy resolution observed are the results of changes in the shape of original current pulses generated in the active volume of the counter. In order to confirm the validity of this statement, measurements of the gas amplification factor have been made in a wide count rate range. It is shown that above a certain critical value the gas gain depends on both the operating voltage and the count rate. (author)

  9. Resonance ionization spectroscopy: Counting noble gas atoms

    International Nuclear Information System (INIS)

    Hurst, G.S.; Payne, M.G.; Chen, C.H.; Willis, R.D.; Lehmann, B.E.; Kramer, S.D.

    1981-01-01

    The purpose of this paper is to describe new work on the counting of noble gas atoms, using lasers for the selective ionization and detectors for counting individual particles (electrons or positive ions). When positive ions are counted, various kinds of mass analyzers (magnetic, quadrupole, or time-of-flight) can be incorporated to provide A selectivity. We show that a variety of interesting and important applications can be made with atom-counting techniques which are both atomic number (Z) and mass number (A) selective. (orig./FKS)

  10. Counting and Surveying Homeless Youth: Recommendations from YouthCount 2.0!, a Community-Academic Partnership.

    Science.gov (United States)

    Narendorf, Sarah C; Santa Maria, Diane M; Ha, Yoonsook; Cooper, Jenna; Schieszler, Christine

    2016-12-01

    Communities across the United States are increasing efforts to find and count homeless youth. This paper presents findings and lessons learned from a community/academic partnership to count homeless youth and conduct an in depth research survey focused on the health needs of this population. Over a 4 week recruitment period, 632 youth were counted and 420 surveyed. Methodological successes included an extended counting period, broader inclusion criteria to capture those in unstable housing, use of student volunteers in health training programs, recruiting from magnet events for high risk youth, and partnering with community agencies to disseminate findings. Strategies that did not facilitate recruitment included respondent driven sampling, street canvassing beyond known hotspots, and having community agencies lead data collection. Surveying was successful in gathering data on reasons for homelessness, history in public systems of care, mental health history and needs, sexual risk behaviors, health status, and substance use. Youth were successfully surveyed across housing types including shelters or transitional housing (n = 205), those in unstable housing such as doubled up with friends or acquaintances (n = 75), and those who were literally on the streets or living in a place not meant for human habitation (n = 140). Most youth completed the self-report survey and provided detailed information about risk behaviors. Recommendations to combine research data collection with counting are presented.

  11. Improving the counting efficiency in time-correlated single photon counting experiments by dead-time optimization

    Energy Technology Data Exchange (ETDEWEB)

    Peronio, P.; Acconcia, G.; Rech, I.; Ghioni, M. [Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano (Italy)

    2015-11-15

    Time-Correlated Single Photon Counting (TCSPC) has been long recognized as the most sensitive method for fluorescence lifetime measurements, but often requiring “long” data acquisition times. This drawback is related to the limited counting capability of the TCSPC technique, due to pile-up and counting loss effects. In recent years, multi-module TCSPC systems have been introduced to overcome this issue. Splitting the light into several detectors connected to independent TCSPC modules proportionally increases the counting capability. Of course, multi-module operation also increases the system cost and can cause space and power supply problems. In this paper, we propose an alternative approach based on a new detector and processing electronics designed to reduce the overall system dead time, thus enabling efficient photon collection at high excitation rate. We present a fast active quenching circuit for single-photon avalanche diodes which features a minimum dead time of 12.4 ns. We also introduce a new Time-to-Amplitude Converter (TAC) able to attain extra-short dead time thanks to the combination of a scalable array of monolithically integrated TACs and a sequential router. The fast TAC (F-TAC) makes it possible to operate the system towards the upper limit of detector count rate capability (∼80 Mcps) with reduced pile-up losses, addressing one of the historic criticisms of TCSPC. Preliminary measurements on the F-TAC are presented and discussed.

  12. CalCOFI Larvae Counts Positive Tows

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for eggs captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  13. Set of counts by scintillations for atmospheric samplings

    International Nuclear Information System (INIS)

    Appriou, D.; Doury, A.

    1962-01-01

    The author reports the development of a scintillation-based counting assembly with the following characteristics: a photo-multiplier with a wide photo-cathode, a thin plastic scintillator for the counting of beta + alpha (and possibility of mounting an alpha scintillator), a relatively small own motion with respect to activities to be counted, a weakly varying efficiency. The authors discuss the counting objective, present equipment tests (counter, proportional amplifier and pre-amplifier, input drawer). They describe the apparatus operation, discuss the selection of scintillators, report the study of the own movement (electron-based background noise, total background noise, background noise reduction), discuss counts (influence of the external source, sensitivity to alpha radiations, counting homogeneity, minimum detectable activity) and efficiencies

  14. A Survey of Italian Physicians' Opinion about Stem Cells Research: What Doctors Prefer and What the Law Requires

    Directory of Open Access Journals (Sweden)

    Paola Frati

    2014-01-01

    Full Text Available To evaluate the Italian physicians' knowledge/information level about the therapeutic potential of stem cells, the research choice between embryonic and cordonal stem cells, and the preference between autologous and heterologous storage of cordonal stem cells, we performed a national survey. The questionnaire—distributed to 3361 physicians—involved physicians of different religious orientations and of different medical specialities. Most of the physicians involved (67% were Catholics, and the majority were gynaecologists and paediatricians (43% who are mainly in charge to inform future mothers about the possibility of cordonal stem cells conservation. The majority of the physicians interviewed do not have specific knowledge about stem cells (59%, most of them having only generic information (92%. The largest part of physicians prefer to use umbilical cord blood cells rather than embryonic stem cells. Nevertheless, a large percentage of physicians were in favour of embryo research, especially when embryos are supernumerary (44% versus 34%. Eighty-seven % of the physicians interviewed proved to have a general knowledge about stem cells and believe in their therapeutic potential. They prefer research on cordonal stem cells rather than on embryo stem cells. Although they are in favour of heterologous stem cells donation, they still prefer cryopreservation for personal use.

  15. Track counting in radon dosimetry

    International Nuclear Information System (INIS)

    Fesenbeck, Ingo; Koehler, Bernd; Reichert, Klaus-Martin

    2013-01-01

    The newly developed, computer-controlled track counting system is capable of imaging and analyzing the entire area of nuclear track detectors. The high optical resolution allows a new analysis approach for the process of automated counting using digital image processing technologies. This way, higher exposed detectors can be evaluated reliably by an automated process as well. (orig.)

  16. CalCOFI Egg Counts Positive Tows

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish egg counts and standardized counts for eggs captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets], and...

  17. Regression Models For Multivariate Count Data.

    Science.gov (United States)

    Zhang, Yiwen; Zhou, Hua; Zhou, Jin; Sun, Wei

    2017-01-01

    Data with multivariate count responses frequently occur in modern applications. The commonly used multinomial-logit model is limiting due to its restrictive mean-variance structure. For instance, analyzing count data from the recent RNA-seq technology by the multinomial-logit model leads to serious errors in hypothesis testing. The ubiquity of over-dispersion and complicated correlation structures among multivariate counts calls for more flexible regression models. In this article, we study some generalized linear models that incorporate various correlation structures among the counts. Current literature lacks a treatment of these models, partly due to the fact that they do not belong to the natural exponential family. We study the estimation, testing, and variable selection for these models in a unifying framework. The regression models are compared on both synthetic and real RNA-seq data.

  18. Validity of total leucocytes count and neutrophil count (differential leucocytes) in diagnosing suspected acute appendicitis

    International Nuclear Information System (INIS)

    Anwar, M.W.; Abid, I.

    2012-01-01

    Objective: To compare the diagnostic accuracy of Total Leucocytes Count (TLC) with Neutrophil count; Differential Leucocytes Count (DLC) in diagnosing cases of suspected acute appendicitis. Study design: Validation study. Place and duration of the study: Department of Surgery, Combined Military Hospital (CMH) Rawalpindi, from April 2008 to October 2008. Method: A total of 100 patients of Pain right iliac fossae who underwent appendicectomy were included. Detailed history of all the patients was taken for pain in right lower abdomen, its severity, its nature, relieving or provoking factors. Clinical examination was done in detail. Total and Differential Leucocytes Count was done. Every patient's appendix was examined grossly after appendicectomy for evidence of appendicitis. Diagnostic measures of TLC and DLC were calculated by standard formulas. Results: Sensitivity and specificity of TLC is 86.9% and 81.25% respectively and that of DLC is 82% and 68.75% respectively. Accuracy was 86% for TLC and 80% for DLC. Conclusion: TLC is more sensitive, specific and accurate test as compared to DLC and it should be used as diagnostic aid for suspected acute appendicitis cases. (author)

  19. Enhanced counting efficiency of Cerenkov radiation from bismuth-210

    International Nuclear Information System (INIS)

    Peck, G.A.; Smith, J.D.

    1998-01-01

    This paper describes the measurement of 210 Bi by Cerenkov counting in a commercial liquid scintillation counter. The counting efficiency in water is 0.17 counts per second per Becquerel (17%). When the enhancers Triton X-100 (15% v/v) and sodium salicylate (1% m/v) are added to the solution the counting efficiency for 210 Bi increases from 17% to 75%. The 210 Po daughter of 210 Bi causes interference of 0.85 counts per second per Becquerel in the presence of the enhancers but not in water. When 210 Bi and 210 Po are present in secular equilibrium the total counting efficiency is 160%. When 210 Bi and 210 Po are not in secular equilibrium the 210 Po can be removed immediately before counting by plating onto silver foil. The use of the enhancers gives a substantial increase in counting efficiency compared to counting in water. Compared with solutions used in liquid scintillation counting the enhancer solution is inexpensive and can be disposed of without environmental hazard. (author)

  20. Clean Hands Count

    Medline Plus

    Full Text Available ... why Close Clean Hands Count Centers for Disease Control and Prevention (CDC) Loading... Unsubscribe from Centers for Disease Control and Prevention (CDC)? Cancel Unsubscribe Working... Subscribe Subscribed ...

  1. Design and development of multiple sample counting setup

    International Nuclear Information System (INIS)

    Rath, D.P.; Murali, S.; Babu, D.A.R.

    2010-01-01

    Full text: The analysis of active samples on regular basis for ambient air activity and floor contamination from radio chemical lab accounts for major chunk of the operational activity in Health Physicist's responsibility. The requirement for daily air sample analysis on immediate counting and delayed counting from various labs in addition to samples of smear swipe check of lab led to the urge for development of system that could cater multiple sample analysis in a time programmed manner on a single sample loading. A multiple alpha/beta counting system for counting was designed and fabricated. It has arrangements for loading 10 samples in slots in order, get counted in a time programmed manner with results displayed and records maintained in PC. The paper describes the design and development of multiple sample counting setup presently in use at the facility has resulted in reduction of man-hour consumption in counting and recording of the results

  2. Automated vehicle counting using image processing and machine learning

    Science.gov (United States)

    Meany, Sean; Eskew, Edward; Martinez-Castro, Rosana; Jang, Shinae

    2017-04-01

    Vehicle counting is used by the government to improve roadways and the flow of traffic, and by private businesses for purposes such as determining the value of locating a new store in an area. A vehicle count can be performed manually or automatically. Manual counting requires an individual to be on-site and tally the traffic electronically or by hand. However, this can lead to miscounts due to factors such as human error A common form of automatic counting involves pneumatic tubes, but pneumatic tubes disrupt traffic during installation and removal, and can be damaged by passing vehicles. Vehicle counting can also be performed via the use of a camera at the count site recording video of the traffic, with counting being performed manually post-recording or using automatic algorithms. This paper presents a low-cost procedure to perform automatic vehicle counting using remote video cameras with an automatic counting algorithm. The procedure would utilize a Raspberry Pi micro-computer to detect when a car is in a lane, and generate an accurate count of vehicle movements. The method utilized in this paper would use background subtraction to process the images and a machine learning algorithm to provide the count. This method avoids fatigue issues that are encountered in manual video counting and prevents the disruption of roadways that occurs when installing pneumatic tubes

  3. Calculating concentration of inhaled radiolabeled particles from external gamma counting: External counting efficiency and attenuation coefficient of thorax

    International Nuclear Information System (INIS)

    Langenback, E.G.; Foster, W.M.; Bergofsky, E.H.

    1989-01-01

    We determined the overall external counting efficiency of radiolabeled particles deposited in the sheep lung. This efficiency permits the noninvasive calculation of the number of particles and microcuries from gamma-scintillation lung images of the live sheep. Additionally, we have calculated the attenuation of gamma radiation (120 keV) by the posterior chest wall and the gamma-scintillation camera collection efficiency of radiation emitted from the lung. Four methods were employed in our experiments: (1) by light microscopic counting of discrete carbonized polystyrene particles with a count median diameter (CMD) of 2.85 microns and tagged with cobalt-57, we delineated a linear relationship between the number of particles and the emitted counts per minute (cpm) detected by well scintillation counting; (2) from this conversion relationship we determined the number of particles inhaled and deposited in the lungs by scintillation counting fragments of dissected lung at autopsy; (3) we defined a linear association between the number of particles or microcuries contained in the lung and the emitted radiation as cpm detected by a gamma scintillation camera in the live sheep prior to autopsy; and (4) we compared the emitted radiation from the lungs of the live sheep to that of whole excised lungs in order to calculate the attenuation coefficient (ac) of the chest wall. The mean external counting efficiency was 4.00 X 10(4) particles/cpm (5.1 X 10(-3) microCi/cpm), the camera collection efficiency was 1 cpm/10(4) disintegrations per minute (dpm), and the ac had a mean of 0.178/cm. The external counting efficiency remained relatively constant over a range of particles and microcuries, permitting a more general use of this ratio to estimate number of particles or microcuries depositing after inhalation in a large mammalian lung if a similarly collimated gamma camera system is used

  4. Clean Hands Count

    Medline Plus

    Full Text Available ... Clean Hands Count Centers for Disease Control and Prevention (CDC) Loading... Unsubscribe from Centers for Disease Control and Prevention (CDC)? Cancel Unsubscribe Working... Subscribe Subscribed Unsubscribe 65K ...

  5. Clean Hands Count

    Medline Plus

    Full Text Available ... Clean Hands Count Centers for Disease Control and Prevention (CDC) Loading... Unsubscribe from Centers for Disease Control and Prevention (CDC)? Cancel Unsubscribe Working... Subscribe Subscribed Unsubscribe 66K ...

  6. Algorithm for counting large directed loops

    Energy Technology Data Exchange (ETDEWEB)

    Bianconi, Ginestra [Abdus Salam International Center for Theoretical Physics, Strada Costiera 11, 34014 Trieste (Italy); Gulbahce, Natali [Theoretical Division and Center for Nonlinear Studies, Los Alamos National Laboratory, NM 87545 (United States)

    2008-06-06

    We derive a Belief-Propagation algorithm for counting large loops in a directed network. We evaluate the distribution of the number of small loops in a directed random network with given degree sequence. We apply the algorithm to a few characteristic directed networks of various network sizes and loop structures and compare the algorithm with exhaustive counting results when possible. The algorithm is adequate in estimating loop counts for large directed networks and can be used to compare the loop structure of directed networks and their randomized counterparts.

  7. Logistic regression for dichotomized counts.

    Science.gov (United States)

    Preisser, John S; Das, Kalyan; Benecha, Habtamu; Stamm, John W

    2016-12-01

    Sometimes there is interest in a dichotomized outcome indicating whether a count variable is positive or zero. Under this scenario, the application of ordinary logistic regression may result in efficiency loss, which is quantifiable under an assumed model for the counts. In such situations, a shared-parameter hurdle model is investigated for more efficient estimation of regression parameters relating to overall effects of covariates on the dichotomous outcome, while handling count data with many zeroes. One model part provides a logistic regression containing marginal log odds ratio effects of primary interest, while an ancillary model part describes the mean count of a Poisson or negative binomial process in terms of nuisance regression parameters. Asymptotic efficiency of the logistic model parameter estimators of the two-part models is evaluated with respect to ordinary logistic regression. Simulations are used to assess the properties of the models with respect to power and Type I error, the latter investigated under both misspecified and correctly specified models. The methods are applied to data from a randomized clinical trial of three toothpaste formulations to prevent incident dental caries in a large population of Scottish schoolchildren. © The Author(s) 2014.

  8. Housing Inventory Count

    Data.gov (United States)

    Department of Housing and Urban Development — This report displays the data communities reported to HUD about the nature of their dedicated homeless inventory, referred to as their Housing Inventory Count (HIC)....

  9. Multiple-Event, Single-Photon Counting Imaging Sensor

    Science.gov (United States)

    Zheng, Xinyu; Cunningham, Thomas J.; Sun, Chao; Wang, Kang L.

    2011-01-01

    The single-photon counting imaging sensor is typically an array of silicon Geiger-mode avalanche photodiodes that are monolithically integrated with CMOS (complementary metal oxide semiconductor) readout, signal processing, and addressing circuits located in each pixel and the peripheral area of the chip. The major problem is its single-event method for photon count number registration. A single-event single-photon counting imaging array only allows registration of up to one photon count in each of its pixels during a frame time, i.e., the interval between two successive pixel reset operations. Since the frame time can t be too short, this will lead to very low dynamic range and make the sensor merely useful for very low flux environments. The second problem of the prior technique is a limited fill factor resulting from consumption of chip area by the monolithically integrated CMOS readout in pixels. The resulting low photon collection efficiency will substantially ruin any benefit gained from the very sensitive single-photon counting detection. The single-photon counting imaging sensor developed in this work has a novel multiple-event architecture, which allows each of its pixels to register as more than one million (or more) photon-counting events during a frame time. Because of a consequently boosted dynamic range, the imaging array of the invention is capable of performing single-photon counting under ultra-low light through high-flux environments. On the other hand, since the multiple-event architecture is implemented in a hybrid structure, back-illumination and close-to-unity fill factor can be realized, and maximized quantum efficiency can also be achieved in the detector array.

  10. Lazy reference counting for the Microgrid

    NARCIS (Netherlands)

    Poss, R.; Grelck, C.; Herhut, S.; Scholz, S.-B.

    2012-01-01

    This papers revisits non-deferred reference counting, a common technique to ensure that potentially shared large heap objects can be reused safely when they are both input and output to computations. Traditionally, thread-safe reference counting exploit implicit memory-based communication of counter

  11. Clean Hands Count

    Medline Plus

    Full Text Available ... stop Loading... Watch Queue Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. Working... Not now Try it free Find ...

  12. Preverbal and verbal counting and computation.

    Science.gov (United States)

    Gallistel, C R; Gelman, R

    1992-08-01

    We describe the preverbal system of counting and arithmetic reasoning revealed by experiments on numerical representations in animals. In this system, numerosities are represented by magnitudes, which are rapidly but inaccurately generated by the Meck and Church (1983) preverbal counting mechanism. We suggest the following. (1) The preverbal counting mechanism is the source of the implicit principles that guide the acquisition of verbal counting. (2) The preverbal system of arithmetic computation provides the framework for the assimilation of the verbal system. (3) Learning to count involves, in part, learning a mapping from the preverbal numerical magnitudes to the verbal and written number symbols and the inverse mappings from these symbols to the preverbal magnitudes. (4) Subitizing is the use of the preverbal counting process and the mapping from the resulting magnitudes to number words in order to generate rapidly the number words for small numerosities. (5) The retrieval of the number facts, which plays a central role in verbal computation, is mediated via the inverse mappings from verbal and written numbers to the preverbal magnitudes and the use of these magnitudes to find the appropriate cells in tabular arrangements of the answers. (6) This model of the fact retrieval process accounts for the salient features of the reaction time differences and error patterns revealed by experiments on mental arithmetic. (7) The application of verbal and written computational algorithms goes on in parallel with, and is to some extent guided by, preverbal computations, both in the child and in the adult.

  13. Determining Gate Count Reliability in a Library Setting

    OpenAIRE

    Jeffrey Phillips

    2016-01-01

    Objective – Patron counts are a common form of measurement for library assessment. To develop accurate library statistics, it is necessary to determine any differences between various counting devices. A yearlong comparison between card reader turnstiles and laser gate counters in a university library sought to offer a standard percentage of variance and provide suggestions to increase the precision of counts. Methods – The collection of library exit counts identified the differences be...

  14. Counting Word Frequencies with Python

    Directory of Open Access Journals (Sweden)

    William J. Turkel

    2012-07-01

    Full Text Available Your list is now clean enough that you can begin analyzing its contents in meaningful ways. Counting the frequency of specific words in the list can provide illustrative data. Python has an easy way to count frequencies, but it requires the use of a new type of variable: the dictionary. Before you begin working with a dictionary, consider the processes used to calculate frequencies in a list.

  15. Computerized radioautographic grain counting

    International Nuclear Information System (INIS)

    McKanna, J.A.; Casagrande, V.A.

    1985-01-01

    In recent years, radiolabeling techniques have become fundamental assays in physiology and biochemistry experiments. They also have assumed increasingly important roles in morphologic studies. Characteristically, radioautographic analysis of structure has been qualitative rather than quantitative, however, microcomputers have opened the door to several methods for quantifying grain counts and density. The overall goal of this chapter is to describe grain counting using the Bioquant, an image analysis package based originally on the Apple II+, and now available for several popular microcomputers. The authors discuss their image analysis procedures by applying them to a study of development in the central nervous system

  16. Cerenkov counting and Cerenkov-scintillation counting with high refractive index organic liquids using a liquid scintillation counter

    International Nuclear Information System (INIS)

    Wiebe, L.I.; Helus, F.; Maier-Borst, W.

    1978-01-01

    18 F and 14 C radioactivity was measured in methyl salicylate (MS), a high refractive index hybrid Cherenkov-scintillation generating medium, using a liquid scintillation counter. At concentrations of up to 21.4%, in MS, dimethyl sulfoxide (DMSO) quenched 14 C fluorescence, and with a 10-fold excess of DMSO over MS, 18 F count rates were reduced below that for DMSO alone, probably as a result of concentration-independent self-quenching due to 'dark-complex' formation. DMSO in lower concentrations did not reduce the counting efficiency of 18 F in MS. Nitrobenzene was a concentration-dependent quencher for both 14 C and 18 F in MS. Chlorobenzene (CB) and DMSO were both found to be weak Cherenkov generators with 18 F. Counting efficiencies for 18 F in MS, CB, and DMSO were 50.3, 7.8 and 4.3% respectively in the coincidence counting mode, and 58.1, 13.0 and 6.8% in the singles mode. 14 C efficiencies were 14.4 and 22.3% for coincidence and singles respectively, and 15.3 and 42.0% using a modern counter designed for coincidence and single photon counting. The high 14 C and 18 F counting efficiency in MS are discussed with respect to excitation mechanism, on the basis of quench and channels ratios changes observed. It is proposed that MS functions as an efficient Cherenkov-scintillation generator for high-energy beta emitters such as 18 F, and as a low-efficiency scintillator for weak beta emitting radionuclides such as 14 C. (author)

  17. Relationship between salivary flow rates and Candida albicans counts.

    Science.gov (United States)

    Navazesh, M; Wood, G J; Brightman, V J

    1995-09-01

    Seventy-one persons (48 women, 23 men; mean age, 51.76 years) were evaluated for salivary flow rates and Candida albicans counts. Each person was seen on three different occasions. Samples of unstimulated whole, chewing-stimulated whole, acid-stimulated parotid, and candy-stimulated parotid saliva were collected under standardized conditions. An oral rinse was also obtained and evaluated for Candida albicans counts. Unstimulated and chewing-stimulated whole flow rates were negatively and significantly (p Candida counts. Unstimulated whole saliva significantly (p Candida counts of 0 versus or = 500 count. Differences in stimulated parotid flow rates were not significant among different levels of Candida counts. The results of this study reveal that whole saliva is a better predictor than parotid saliva in identification of persons with high Candida albicans counts.

  18. Reticulocyte Count Test

    Science.gov (United States)

    ... htm. (2004 Summer). Immature Reticulocyte Fraction(IRF). The Pathology Center Newsletter v9(1). [On-line information]. Available ... Company, Philadelphia, PA [18th Edition]. Levin, M. (2007 March 8, Updated). Reticulocyte Count. MedlinePlus Medical Encyclopedia [On- ...

  19. Temporal trends in sperm count

    DEFF Research Database (Denmark)

    Levine, Hagai; Jørgensen, Niels; Martino-Andrade, Anderson

    2017-01-01

    a predefined protocol 7518 abstracts were screened and 2510 full articles reporting primary data on SC were reviewed. A total of 244 estimates of SC and TSC from 185 studies of 42 935 men who provided semen samples in 1973-2011 were extracted for meta-regression analysis, as well as information on years.......006, respectively). WIDER IMPLICATIONS: This comprehensive meta-regression analysis reports a significant decline in sperm counts (as measured by SC and TSC) between 1973 and 2011, driven by a 50-60% decline among men unselected by fertility from North America, Europe, Australia and New Zealand. Because......BACKGROUND: Reported declines in sperm counts remain controversial today and recent trends are unknown. A definitive meta-analysis is critical given the predictive value of sperm count for fertility, morbidity and mortality. OBJECTIVE AND RATIONALE: To provide a systematic review and meta-regression...

  20. CERNDxCTA counting mode chip

    International Nuclear Information System (INIS)

    Moraes, D.; Kaplon, J.; Nygard, E.

    2008-01-01

    This ASIC is a counting mode front-end electronic optimized for the readout of CdZnTe/CdTe and silicon sensors, for possible use in applications where the flux of ionizing radiation is high. The chip is implemented in 0.25 μm CMOS technology. The circuit comprises 128 channels equipped with a transimpedance amplifier followed by a gain shaper stage with 21 ns peaking time, two discriminators and two 18-bit counters. The channel architecture is optimized for the detector characteristics in order to achieve the best energy resolution at counting rates of up to 5 M counts/second. The amplifier shows a linear sensitivity of 118 mV/fC and an equivalent noise charge of about 711 e - , for a detector capacitance of 5 pF. Complete evaluation of the circuit is presented using electronic pulses and pixel detectors

  1. Seed counting system evaluation using arduino microcontroller

    Directory of Open Access Journals (Sweden)

    Paulo Fernando Escobar Paim

    2018-01-01

    Full Text Available The development of automated systems has been highlighted in the most diverse productive sectors, among them, the agricultural sector. These systems aim to optimize activities by increasing operational efficiency and quality of work. In this sense, the present work has the objective of evaluating a prototype developed for seed count in laboratory, using Arduino microcontroller. The prototype of the system for seed counting was built using a dosing mechanism commonly used in seeders, electric motor, Arduino Uno, light dependent resistor and light emitting diode. To test the prototype, a completely randomized design (CRD was used in a two-factorial scheme composed of three groups defined according to the number of seeds (500, 1000 and 1500 seeds tested, three speeds of the dosing disc that allowed the distribution in 17, 21 and 32 seeds per second, with 40 repetitions evaluating the seed counting prototype performance in different speeds. The prototype of the bench counter showed a moderate variability of seed number of counted within the nine tests and a high precision in the seed count on the distribution speeds of 17 and 21 seeds per second (s-1 up to 1500 seeds tested. Therefore, based on the observed results, the developed prototype presents itself as an excellent tool for counting seeds in laboratory.

  2. Using DNA to test the utility of pellet-group counts as an index of deer counts

    Science.gov (United States)

    T. J. Brinkman; D. K. Person; W. Smith; F. Stuart Chapin; K. McCoy; M. Leonawicz; K. Hundertmark

    2013-01-01

    Despite widespread use of fecal pellet-group counts as an index of ungulate density, techniques used to convert pellet-group numbers to ungulate numbers rarely are based on counts of known individuals, seldom evaluated across spatial and temporal scales, and precision is infrequently quantified. Using DNA from fecal pellets to identify individual deer, we evaluated the...

  3. Tutorial on X-ray photon counting detector characterization.

    Science.gov (United States)

    Ren, Liqiang; Zheng, Bin; Liu, Hong

    2018-01-01

    Recent advances in photon counting detection technology have led to significant research interest in X-ray imaging. As a tutorial level review, this paper covers a wide range of aspects related to X-ray photon counting detector characterization. The tutorial begins with a detailed description of the working principle and operating modes of a pixelated X-ray photon counting detector with basic architecture and detection mechanism. Currently available methods and techniques for charactering major aspects including energy response, noise floor, energy resolution, count rate performance (detector efficiency), and charge sharing effect of photon counting detectors are comprehensively reviewed. Other characterization aspects such as point spread function (PSF), line spread function (LSF), contrast transfer function (CTF), modulation transfer function (MTF), noise power spectrum (NPS), detective quantum efficiency (DQE), bias voltage, radiation damage, and polarization effect are also remarked. A cadmium telluride (CdTe) pixelated photon counting detector is employed for part of the characterization demonstration and the results are presented. This review can serve as a tutorial for X-ray imaging researchers and investigators to understand, operate, characterize, and optimize photon counting detectors for a variety of applications.

  4. Scintillation counting apparatus

    International Nuclear Information System (INIS)

    Noakes, J.E.

    1978-01-01

    Apparatus is described for the accurate measurement of radiation by means of scintillation counters and in particular for the liquid scintillation counting of both soft beta radiation and gamma radiation. Full constructional and operating details are given. (UK)

  5. Project and construction of counting system for neutron probe

    International Nuclear Information System (INIS)

    Monteiro, W.P.

    1985-01-01

    A counting system was developed for coupling neutron probe aiming to register pulses produced by slow neutron interaction in the detector. The neutron probe consists of fast neutron source, thermal neutron detector, amplifier circuit and pulse counting circuit. The counting system is composed by counting circuit, timer and signal circuit. (M.C.K.)

  6. Redescription of Chabaudacuaria multispinosa (Pérez Vigueras, 1938) n. g., n. comb. (Nematoda: Spirurida: Acuariidae) based on specimens from Ardea herodias L. and Nyctanassa violacea (L.) (Ardeidae) in Florida.

    Science.gov (United States)

    Mutafchiev, Yasen; Kinsella, John M

    2012-10-01

    Chabaudacuaria n. g. is erected, as monotypic, for C. multispinosa (Pérez Vigueras, 1938) n. comb. (Spirurida: Acuariidae) [syns Cheilospirura multispinosa Pérez Vigueras, 1938; Acuaria multispinosa (Pérez Vigueras, 1938) Yamaguti, 1961]. This species, a parasite of various ardeid birds, is redescribed by means of light and scanning electron microscopy based on material from great blue herons Ardea herodias L. and yellow-crowned night herons Nyctanassa violacea (L.) in Florida, USA. Chabaudacuaria n. g. resembles Acuaria Bremser, 1811, Cheilospirura Diesing, 1861, Skrjabinocerca Schikhobalova, 1930 and Xenocordon Mawson, 1982 in its straight cordons which do not anastomose. However, it can be distinguished from them by the didelphic-prodelphic uterus and the absence of caudal alae in the males. In the pattern of its cordons (consisting of a row of plates and a longitudinal ridge) and the absence of an area rugosa, the new genus is similar to Chevreuxia Seurat, 1918, Syncuaria Gil'bert, 1927, Aviculariella Wehr, 1931, Skrjabinocara Kurashvili, 1940, Decorataria Sobolev, 1949 and Desportesius Chabaud & Campana, 1949, which are characterised by anastomosing cordons. The didelphic-prodelphic female reproductive system of Chabaudacuaria is intermediate between the didelphic-amphidelphic uterus of Chevreuxia and the monodelphic-prodelphic uterus of Syncuaria, Aviculariella, Skrjabinocara, Desportesius and Decorataria. Therefore, the straight and non-anastomosing cordons are considered to be autapomorphic for Chabaudacuaria.

  7. Counts and colors of faint galaxies

    International Nuclear Information System (INIS)

    Kron, R.G.

    1980-01-01

    The color distribution of faint galaxies is an observational dimension which has not yet been fully exploited, despite the important constraints obtainable for galaxy evolution and cosmology. Number-magnitude counts alone contain very diluted information about the state of things because galaxies from a wide range in redshift contribute to the counts at each magnitude. The most-frequently-seen type of galaxy depends on the luminosity function and the relative proportions of galaxies of different spectral classes. The addition of color as a measured quantity can thus considerably sharpen the interpretation of galaxy counts since the apparent color depends on the redshift and rest-frame spectrum. (Auth.)

  8. Clean Hands Count

    Medline Plus

    Full Text Available ... is starting stop Loading... Watch Queue Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos ... empower patients to play a role in their care by asking or reminding healthcare providers to clean ...

  9. Cerenkov counting and Cerenkov-scintillation counting with high refractive index organic liquids using a liquid scintillation counter

    Energy Technology Data Exchange (ETDEWEB)

    Wiebe, L I; Helus, F; Maier-Borst, W [Deutsches Krebsforschungszentrum, Heidelberg (Germany, F.R.). Inst. fuer Nuklearmedizin

    1978-06-01

    /sup 18/F and /sup 14/C radioactivity was measured in methyl salicylate (MS), a high refractive index hybrid Cherenkov-scintillation generating medium, using a liquid scintillation counter. At concentrations of up to 21.4%, in MS, dimethyl sulfoxide (DMSO) quenched /sup 14/C fluorescence, and with a 10-fold excess of DMSO over MS, /sup 18/F count rates were reduced below that for DMSO alone, probably as a result of concentration-independent self-quenching due to 'dark-complex' formation. DMSO in lower concentrations did not reduce the counting efficiency of /sup 18/F in MS. Nitrobenzene was a concentration-dependent quencher for both /sup 14/C and /sup 18/F in MS. Chlorobenzene (CB) and DMSO were both found to be weak Cherenkov generators with /sup 18/F. Counting efficiencies for /sup 18/F in MS, CB, and DMSO were 50.3, 7.8 and 4.3% respectively in the coincidence counting mode, and 58.1, 13.0 and 6.8% in the singles mode. /sup 14/C efficiencies were 14.4 and 22.3% for coincidence and singles respectively, and 15.3 and 42.0% using a modern counter designed for coincidence and single photon counting. The high /sup 14/C and /sup 18/F counting efficiency in MS are discussed with respect to excitation mechanism, on the basis of quench and channels ratios changes observed. It is proposed that MS functions as an efficient Cherenkov-scintillation generator for high-energy beta emitters such as /sup 18/F, and as a low-efficiency scintillator for weak beta emitting radionuclides such as /sup 14/C.

  10. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 396 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Thomas Jefferson University & Jefferson ...

  11. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 094 views 1:19 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 411,974 ...

  12. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 741 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  13. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 786 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 413,702 ...

  14. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 824 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 409,492 ...

  15. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 414 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Thomas Jefferson University & Jefferson ...

  16. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 869 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  17. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 585 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 413,097 ...

  18. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 319 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  19. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 285 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  20. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 029 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 411,974 ...

  1. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 384 views 1:19 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Thomas Jefferson University & Jefferson ...

  2. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 460 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Thomas Jefferson University & Jefferson ...

  3. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 033 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  4. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 043 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 411,292 ...

  5. Development of a mobile application for manual traffic counts

    Directory of Open Access Journals (Sweden)

    Ghanim Mohammad

    2017-01-01

    Full Text Available The use of technology in performing traffic counts has become widely used by many transportation agencies and private sectors. Different technologies have been employed to perform such counts, such as inductive loops, image processing, Bluetooth technologies, and laser and infrared technologies. However, the use of these advanced technologies come with extra cost to develop, install, and maintain. While the use of advanced technologies provide reliable traffic counts and vehicle classifications data, the use of manual traffic is an inevitable task. Manual traffic counts can serve different purposes, such as performing quality control or conducting short-term traffic survey. Manual traffic counts are usually conducted with the use of the traditional paper-and-pencil approach or the use of hand-held devices that are specifically developed to assess performing manual traffic counts. In this paper, the development of a mobile app that can be used to assist those who need to perform manual traffic counts. The app can be used by many public agencies, private sectors, and college students to collect their traffic data. It also provides users with the capabilities of sharing their traffic counts instantly, where traffic counts can be extracted and processed quickly by other parties.

  6. SUMS Counts-Related Projects

    Data.gov (United States)

    Social Security Administration — Staging Instance for all SUMs Counts related projects including: Redeterminations/Limited Issue, Continuing Disability Resolution, CDR Performance Measures, Initial...

  7. Change-Point Methods for Overdispersed Count Data

    National Research Council Canada - National Science Library

    Wilken, Brian A

    2007-01-01

    .... Although the Poisson model is often used to model count data, the two-parameter gamma-Poisson mixture parameterization of the negative binomial distribution is often a more adequate model for overdispersed count data...

  8. Leveraging multiple datasets for deep leaf counting

    OpenAIRE

    Dobrescu, Andrei; Giuffrida, Mario Valerio; Tsaftaris, Sotirios A

    2017-01-01

    The number of leaves a plant has is one of the key traits (phenotypes) describing its development and growth. Here, we propose an automated, deep learning based approach for counting leaves in model rosette plants. While state-of-the-art results on leaf counting with deep learning methods have recently been reported, they obtain the count as a result of leaf segmentation and thus require per-leaf (instance) segmentation to train the models (a rather strong annotation). Instead, our method tre...

  9. Detection limits for radioanalytical counting techniques

    International Nuclear Information System (INIS)

    Hartwell, J.K.

    1975-06-01

    In low-level radioanalysis it is usually necessary to test the sample net counts against some ''Critical Level'' in order to determine if a given result indicates detection. This is an interpretive review of the work by Nicholson (1963), Currie (1968) and Gilbert (1974). Nicholson's evaluation of three different computational formulas for estimation of the ''Critical Level'' is discussed. The details of Nicholson's evaluation are presented along with a basic discussion of the testing procedures used. Recommendations are presented for calculation of confidence intervals, for reporting of analytical results, and for extension of the derived formula to more complex cases such as multiple background counts, multiple use of a single background count, and gamma spectrometric analysis

  10. Counts of low-Redshift SDSS quasar candidates

    International Nuclear Information System (INIS)

    Zeljko Ivezic

    2004-01-01

    We analyze the counts of low-redshift quasar candidates selected using nine-epoch SDSS imaging data. The co-added catalogs are more than 1 mag deeper than single-epoch SDSS data, and allow the selection of low-redshift quasar candidates using UV-excess and also variability techniques. The counts of selected candidates are robustly determined down to g = 21.5. This is about 2 magnitudes deeper than the position of a change in the slope of the counts reported by Boyle (and others) (1990, 2000) for a sample selected by UV-excess, and questioned by Hawkins and Veron (1995), who utilized a variability-selected sample. Using SDSS data, we confirm a change in the slope of the counts for both UV-excess and variability selected samples, providing strong support for the Boyle (and others) results

  11. Liquid scintillation counting of chlorophyll

    International Nuclear Information System (INIS)

    Fric, F.; Horickova, B.; Haspel-Horvatovic, E.

    1975-01-01

    A precise and reproducible method of liquid scintillation counting was worked out for measuring the radioactivity of 14 C-labelled chlorophyll a and chlorophyll b solutions without previous bleaching. The spurious count rate caused by luminescence of the scintillant-chlorophyll system is eliminated by using a suitable scintillant and by measuring the radioactivity at 4 to 8 0 C after an appropriate time of dark adaptation. Bleaching of the chlorophyll solutions is necessary only for measuring of very low radioactivity. (author)

  12. Radiation Counting System Software Using Visual Basic

    International Nuclear Information System (INIS)

    Nanda Nagara; Didi Gayani

    2009-01-01

    It has been created a Gamma Radiation Counting System using interface card, which paired with Personal Computer (PC) and operated by the Visual Basic program. The program was set through varied menu selections such as ”Multi Counting” , ”Counting and Record” and ”View Data”. An interface card for data acquisition was formed by using AMD9513 components as a counter and timer which can be programmed. This counting system was tested and used in waste facility in PTNBR and the result is quite good. (author)

  13. Protecting count queries in study design.

    Science.gov (United States)

    Vinterbo, Staal A; Sarwate, Anand D; Boxwala, Aziz A

    2012-01-01

    Today's clinical research institutions provide tools for researchers to query their data warehouses for counts of patients. To protect patient privacy, counts are perturbed before reporting; this compromises their utility for increased privacy. The goal of this study is to extend current query answer systems to guarantee a quantifiable level of privacy and allow users to tailor perturbations to maximize the usefulness according to their needs. A perturbation mechanism was designed in which users are given options with respect to scale and direction of the perturbation. The mechanism translates the true count, user preferences, and a privacy level within administrator-specified bounds into a probability distribution from which the perturbed count is drawn. Users can significantly impact the scale and direction of the count perturbation and can receive more accurate final cohort estimates. Strong and semantically meaningful differential privacy is guaranteed, providing for a unified privacy accounting system that can support role-based trust levels. This study provides an open source web-enabled tool to investigate visually and numerically the interaction between system parameters, including required privacy level and user preference settings. Quantifying privacy allows system administrators to provide users with a privacy budget and to monitor its expenditure, enabling users to control the inevitable loss of utility. While current measures of privacy are conservative, this system can take advantage of future advances in privacy measurement. The system provides new ways of trading off privacy and utility that are not provided in current study design systems.

  14. Alaska Steller Sea Lion Pup Count Database

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This database contains counts of Steller sea lion pups on rookeries in Alaska made between 1961 and 2015. Pup counts are conducted in late June-July. Pups are...

  15. Photon counting and fluctuation of molecular movement

    International Nuclear Information System (INIS)

    Inohara, Koichi

    1978-01-01

    The direct measurement of the fluctuation of molecular motions, which provides with useful information on the molecular movement, was conducted by introducing photon counting method. The utilization of photon counting makes it possible to treat the molecular system consisting of a small number of molecules like a radioisotope in the detection of a small number of atoms, which are significant in biological systems. This method is based on counting the number of photons of the definite polarization emitted in a definite time interval from the fluorescent molecules excited by pulsed light, which are bound to the marked large molecules found in a definite spatial region. Using the probability of finding a number of molecules oriented in a definite direction in the definite spatial region, the probability of counting a number of photons in a definite time interval can be calculated. Thus the measurable count rate of photons can be related with the fluctuation of molecular movement. The measurement was carried out under the condition, in which the probability of the simultaneous arrival of more than two photons at a detector is less than 1/100. As the experimental results, the resolving power of photon-counting apparatus, the frequency distribution of the number of photons of some definite polarization counted for 1 nanosecond are shown. In the solution, the variance of the number of molecules of 500 on the average is 1200, which was estimated from the experimental data by assuming normal distribution. This departure from the Poisson distribution means that a certain correlation does exist in molecular movement. In solid solution, no significant deviation was observed. The correlation existing in molecular movement can be expressed in terms of the fluctuation of the number of molecules. (Nakai, Y.)

  16. Restaurant 2 goes Cordon Bleu

    CERN Multimedia

    2007-01-01

    The Domaine de Chouilly. Who said fine cuisine was too expensive? For a whole week between the 19th and 23rd February you will have the opportunity to enjoy gastronomic delights a short walk away from your office for only 17 CHF. The Chef and his colleagues from the famous Chateauvieux restaurant at the Domaine de Chouilly will be coming to Restaurant No. 2 to prepare a different gastronomic delight each day and will bring with them their own ingredients, equipment and even their own crockery! The list of fare is mouthwatering: Limousin lamb filet au gratin served with two-olive tapenade, and filet of char served with dill and candied lemon are just two of the delicious dishes on the week's menu. Restaurant No. 2 has rustled up another innovation: at the beginning of March it will be starting a pasta serving area on the ground floor called 'The Olivetto Corner'. 'The Corner is designed for customers who don't have much time and for those who like their pasta al dente,' explains Jean-Marie Fornerod, who mana...

  17. Current status of liquid scintillation counting

    International Nuclear Information System (INIS)

    Klingler, G.W.

    1981-01-01

    Scintillation counting of alpha particles has been used since the turn of the century. The advent of pulse shape discrimination has made this method of detection accurate and reliable. The history, concepts and development of scintillation counting and pulse shape discrimination are discussed. A brief look at the ongoing work in the consolidation of components now used for pulse shape discrimination is included

  18. Counting Possibilia

    Directory of Open Access Journals (Sweden)

    Alfredo Tomasetta

    2010-06-01

    Full Text Available Timothy Williamson supports the thesis that every possible entity necessarily exists and so he needs to explain how a possible son of Wittgenstein’s, for example, exists in our world:he exists as a merely possible object (MPO, a pure locus of potential. Williamson presents a short argument for the existence of MPOs: how many knives can be made by fitting together two blades and two handles? Four: at the most two are concrete objects, the others being merely possible knives and merely possible objects. This paper defends the idea that one can avoid reference and ontological commitment to MPOs. My proposal is that MPOs can be dispensed with by using the notion of rules of knife-making. I first present a solution according to which we count lists of instructions - selected by the rules - describing physical combinations between components. This account, however, has its own difficulties and I eventually suggest that one can find a way out by admitting possible worlds, entities which are more commonly accepted - at least by philosophers - than MPOs. I maintain that, in answering Williamson’s questions, we count classes of physically possible worlds in which the same instance of a general rule is applied.

  19. Evaluation of misplaced event count rate using a scintillation camera

    International Nuclear Information System (INIS)

    Yanagimoto, Shin-ichi; Tomomitsu, Tatsushi; Muranaka, Akira

    1985-01-01

    Misplaced event count rates were evaluated using an acryl scatter body of various thickness and a gamma camera. The count rate in the region of interest (ROI) within the camera view field, which was thought to represent part of the misplaced event count rate, increased as the thickness of the scatter body was increased to 5 cm, followed by a steep decline in the count rate. On the other hand, the ratio of the count rate in the ROI to the total count rate continuously increased as the thickness of the scatter body was increased. As the thickness of the scatter body was increased, the count rates increased, and the increments of increase were greater in the lower energy region of the photopeak than in the higher energy region. In ranges energy other than the photopeak, the influence of the scatter body on the count rate in the ROI was the greatest at 76 keV, which was the lowest energy we examined. (author)

  20. Counting Knights and Knaves

    Science.gov (United States)

    Levin,Oscar; Roberts, Gerri M.

    2013-01-01

    To understand better some of the classic knights and knaves puzzles, we count them. Doing so reveals a surprising connection between puzzles and solutions, and highlights some beautiful combinatorial identities.

  1. Determining Gate Count Reliability in a Library Setting

    Directory of Open Access Journals (Sweden)

    Jeffrey Phillips

    2016-09-01

    Full Text Available Objective – Patron counts are a common form of measurement for library assessment. To develop accurate library statistics, it is necessary to determine any differences between various counting devices. A yearlong comparison between card reader turnstiles and laser gate counters in a university library sought to offer a standard percentage of variance and provide suggestions to increase the precision of counts. Methods – The collection of library exit counts identified the differences between turnstile and laser gate counter data. Statistical software helped to eliminate any inaccuracies in the collection of turnstile data, allowing this data set to be the base for comparison. Collection intervals were randomly determined and demonstrated periods of slow, average, and heavy traffic. Results – After analyzing 1,039,766 patron visits throughout a year, the final totals only showed a difference of .43% (.0043 between the two devices. The majority of collection periods did not exceed a difference of 3% between the counting instruments. Conclusion – Turnstiles card readers and laser gate counters provide similar levels of reliability when measuring patron activity. Each system has potential counting inaccuracies, but several methods exist to create more precise totals. Turnstile card readers are capable of offering greater detail involving patron identity, but their high cost makes them inaccessible for libraries with lower budgets. This makes laser gate counters an affordable alternative for reliable patron counting in an academic library.

  2. Genome Replikin Count Predicts Increased Infectivity/Lethality of Viruses

    OpenAIRE

    Samuel Bogoch; Elenore S. Bogoch

    2012-01-01

    The genomes of all groups of viruses whose sequences are listed on Pubmed, specimens since 1918, analyzed by a software from Bioradar UK Ltd., contain Replikins which range in concentration from a Replikin Count (number of Replikins per 100 amino acids) of less than 1 to 30 (see accompanying communications for higher Counts in tuberculosis, malaria, and cancer, associated with higher lethality). Counts of less than 4.0 were found in ‘resting’ virus states; Counts greater than 4....

  3. Effects of plutonium redistribution on lung counting

    International Nuclear Information System (INIS)

    Swinth, K.L.

    1976-01-01

    Early counts of Pu deposition in lungs will tend to overestimate lung contents since calibrations are performed with a uniform distribution and since a more favorable geometry exists in contaminated subjects because the activity is closer to the periphery of the lungs. Although the concentration into the outer regions of the lungs continues as evidenced by the autopsy studies, the counts performed by L X-rays will probably underestimate the lung content; because, simplistically, the geometry several years after exposure consists of a spherical shell with a point of activity in the center. This point of activity represents concentration in the lymph nodes from which the 60 keV gamma of 241 Am will be counted, but from which few of the L X-rays will be counted (this is an example of interorgan distribution). When a correction is made to the L X-ray intensity, the lymph node contribution will tend to increase the amount subtracted while correcting for 241 Am X-rays. It is doubtful that the relative increase in X-ray intensity by concentration in the pleural and sub-pleural regions will compensate for this effect. This will make the plutonium burden disappear while the 241 Am can still be detected. This effect has been observed in a case where counts with an intraesophageal probe indicated a substantial lymph node burden. In order to improve the accuracy of in vivo plutonium measurements, an improved understanding of pulmonary distribution and of distribution effects on in vivo counting are required

  4. Use of pliable bags in liquid scintillation counting

    International Nuclear Information System (INIS)

    Simonnet, G.; Jacquet, M.A.; Sharif, A.; Engler, R.

    1981-01-01

    Pliable plastic bags have been used to replace glass or plastic vials for liquid scintillation counting. The two major advantages of this method are the lower cost of the plastic bags and the fact that, per sample, the radioactive waste is significantly reduced. The following parameters have been checked: the impermeability of the bags to various scintillator mixtures and the fact that neither the irregular shape of the bags nor their position in the counting chamber had any effect on the results of the counting. The latter was also constant with time, at least over a period of 10 days. The technique has been used to count the radioactivity of 3 H-DNA precipitates prepared from bacteria and lymphocytes and deposited on filters impregnated with only 200 μl scintillator. It is a method that can be applied to the counting of any samples deposited on filters and insoluble in scintillator. (author)

  5. System and method of liquid scintillation counting

    International Nuclear Information System (INIS)

    Rapkin, E.

    1977-01-01

    A method of liquid scintillation counting utilizing a combustion step to overcome quenching effects comprises novel features of automatic sequential introduction of samples into a combustion zone and automatic sequential collection and delivery of combustion products into a counting zone. 37 claims, 13 figures

  6. BMI in relation to sperm count

    DEFF Research Database (Denmark)

    Sermondade, N; Faure, C; Fezeu, L

    2013-01-01

    BACKGROUND The global obesity epidemic has paralleled a decrease in semen quality. Yet, the association between obesity and sperm parameters remains controversial. The purpose of this report was to update the evidence on the association between BMI and sperm count through a systematic review...... with meta-analysis. METHODS A systematic review of available literature (with no language restriction) was performed to investigate the impact of BMI on sperm count. Relevant studies published until June 2012 were identified from a Pubmed and EMBASE search. We also included unpublished data (n = 717 men...... studies were included in the meta-analysis, resulting in a sample of 13 077 men from the general population and attending fertility clinics. Data were stratified according to the total sperm count as normozoospermia, oligozoospermia and azoospermia. Standardized weighted mean differences in sperm...

  7. Analysis of General Power Counting Rules in Effective Field Theory

    CERN Document Server

    Gavela, B M; Manohar, A V; Merlo, L

    2016-01-01

    We derive the general counting rules for a quantum effective field theory (EFT) in $\\mathsf{d}$ dimensions. The rules are valid for strongly and weakly coupled theories, and predict that all kinetic energy terms are canonically normalized. They determine the energy dependence of scattering cross sections in the range of validity of the EFT expansion. The size of cross sections is controlled by the $\\Lambda$ power counting of EFT, not by chiral counting, even for chiral perturbation theory ($\\chi$PT). The relation between $\\Lambda$ and $f$ is generalized to $\\mathsf{d}$ dimensions. We show that the naive dimensional analysis $4\\pi$ counting is related to $\\hbar$ counting. The EFT counting rules are applied to $\\chi$PT, to Standard Model EFT and to the non-trivial case of Higgs EFT, which combines the $\\Lambda$ and chiral counting rules within a single theory.

  8. Atmospheric mold spore counts in relation to meteorological parameters

    Science.gov (United States)

    Katial, R. K.; Zhang, Yiming; Jones, Richard H.; Dyer, Philip D.

    Fungal spore counts of Cladosporium, Alternaria, and Epicoccum were studied during 8 years in Denver, Colorado. Fungal spore counts were obtained daily during the pollinating season by a Rotorod sampler. Weather data were obtained from the National Climatic Data Center. Daily averages of temperature, relative humidity, daily precipitation, barometric pressure, and wind speed were studied. A time series analysis was performed on the data to mathematically model the spore counts in relation to weather parameters. Using SAS PROC ARIMA software, a regression analysis was performed, regressing the spore counts on the weather variables assuming an autoregressive moving average (ARMA) error structure. Cladosporium was found to be positively correlated (Pmodel was derived for Cladosporium spore counts using the annual seasonal cycle and significant weather variables. The model for Alternaria and Epicoccum incorporated the annual seasonal cycle. Fungal spore counts can be modeled by time series analysis and related to meteorological parameters controlling for seasonallity; this modeling can provide estimates of exposure to fungal aeroallergens.

  9. Pixel-Cluster Counting Luminosity Measurement in ATLAS

    CERN Document Server

    McCormack, William Patrick; The ATLAS collaboration

    2016-01-01

    A precision measurement of the delivered luminosity is a key component of the ATLAS physics program at the Large Hadron Collider (LHC). A fundamental ingredient of the strategy to control the systematic uncertainties affecting the absolute luminosity has been to compare the measurements of several luminometers, most of which use more than one counting technique. The level of consistency across the various methods provides valuable cross-checks as well as an estimate of the detector-related systematic uncertainties. This poster describes the development of a luminosity algorithm based on pixel-cluster counting in the recently installed ATLAS inner b-layer (IBL), using data recorded during the 2015 pp run at the LHC. The noise and background contamination of the luminosity-associated cluster count is minimized by a multi-component fit to the measured cluster-size distribution in the forward pixel modules of the IBL. The linearity, long-term stability and statistical precision of the cluster-counting method are ...

  10. Pixel-Cluster Counting Luminosity Measurement In ATLAS

    CERN Document Server

    AUTHOR|(SzGeCERN)782710; The ATLAS collaboration

    2017-01-01

    A precision measurement of the delivered luminosity is a key component of the ATLAS physics program at the Large Hadron Collider (LHC). A fundamental ingredient of the strategy to control the systematic uncertainties affecting the absolute luminosity has been to compare the measure- ments of several luminometers, most of which use more than one counting technique. The level of consistency across the various methods provides valuable cross-checks as well as an estimate of the detector-related systematic uncertainties. This poster describes the development of a luminosity algorithm based on pixel-cluster counting in the recently installed ATLAS inner b-layer (IBL), using data recorded during the 2015 pp run at the LHC. The noise and background contamination of the luminosity-associated cluster count is minimized by a multi-component fit to the measured cluster-size distribution in the forward pixel modules of the IBL. The linearity, long-term stability and statistical precision of the cluster- counting method a...

  11. Investigation of reduction in background counts of clover detector

    International Nuclear Information System (INIS)

    Kshetri, Ritesh

    2015-01-01

    The peak-to-total ratio can be improved by increasing the full energy peak (FEP) counts and/or by decreasing the background counts. It is notable that FEP counts will be effected by mode of operation, while background counts will be effected by both modes of operation and suppression cases. It would be interesting to know if the reduction in background is caused more by active suppression or by add back process. We introduce a simple formalism to investigate the reduction of background counts for different cases-single crystal or add back mode with active or passive suppression. A more sophisticated formalism for modeling a general composite detector had been presented in a series of six recent papers by the author

  12. Multiple sample, radioactive particle counting apparatus

    International Nuclear Information System (INIS)

    Reddy, R.R.V.; Kelso, D.M.

    1978-01-01

    An apparatus is described for determining the respective radioactive particle sample count being emitted from radioactive particle containing samples. It includes means for modulating the information on the radioactive particles being emitted from the samples, coded detecting means for sequentially detecting different respective coded combinations of the radioactive particles emitted from more than one but less than all of the samples, and processing the modulated information to derive the sample count for each sample. It includes a single light emitting crystal next to a number of samples, an encoder belt sequentially movable between the crystal and the samples. The encoder belt has a coded array of apertures to provide corresponding modulated light pulses from the crystal, and a photomultiplier tube to convert the modulated light pulses to decodable electrical signals for deriving the respective sample count

  13. CERN_DxCTA counting mode chip

    CERN Document Server

    Moraes, D; Nygård, E

    2008-01-01

    This ASIC is a counting mode front-end electronic optimized for the readout of CdZnTe/CdTe and silicon sensors, for possible use in applications where the flux of ionizing radiation is high. The chip is implemented in 0.25 μm CMOS technology. The circuit comprises 128 channels equipped with a transimpedance amplifier followed by a gain shaper stage with 21 ns peaking time, two discriminators and two 18-bit counters. The channel architecture is optimized for the detector characteristics in order to achieve the best energy resolution at counting rates of up to 5 M counts/second. The amplifier shows a linear sensitivity of 118 mV/fC and an equivalent noise charge of about 711 e−, for a detector capacitance of 5 pF. Complete evaluation of the circuit is presented using electronic pulses and pixel detectors.

  14. Allegheny County Traffic Counts

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — Traffic sensors at over 1,200 locations in Allegheny County collect vehicle counts for the Pennsylvania Department of Transportation. Data included in the Health...

  15. A multiwire proportional counter for very high counting rates

    International Nuclear Information System (INIS)

    Barbosa, A.F.; Guedes, G.P.; Tamura, E.; Pepe, I.M.; Oliveira, N.B.

    1997-12-01

    Preliminary measurements in a proportional counter with two independently counting wires showed that counting rates up to 10 6 counts/s per wire can be reached without critical loss in the true versus measured linearity relation. Results obtained with a detector containing 30 active wires (2 mm pitch) are presented. To each wire is associated a fast pre-amplifier and a discriminator channel. Global counting rates in excess to 10 7 events/s are reported. Data acquisition systems are described for 1D (real time) and 2D (off-line) position sensitive detection systems. (author)

  16. Method of inspecting Raschig rings by neutron absorption counting

    International Nuclear Information System (INIS)

    Morris, R.N.; Murri, R.L.; Hume, M.W.

    1979-01-01

    A neutron counting method for inspecting borosilicate glass Raschig rings and an apparatus designed specifically for this method are discussed. The neutron count ratios for rings of a given thickness show a linear correlation to the boron oxide content of the rings. The count ratio also has a linear relationship to the thickness of rings of a given boron oxide content. Consequently, the experimentally-determined count ratio and physically-measured thickness of Raschig rings can be used to statistically predict their boron oxide content and determine whether or not they meet quality control acceptance criteria

  17. Double counting in LDA + DMFT-The example of NiO

    Energy Technology Data Exchange (ETDEWEB)

    Karolak, M., E-mail: mkarolak@physnet.uni-hamburg.d [I. Institut fuer Theoretische Physik, Universitaet Hamburg, Jungiusstrasse 9, D-20355 Hamburg (Germany); Ulm, G.; Wehling, T. [I. Institut fuer Theoretische Physik, Universitaet Hamburg, Jungiusstrasse 9, D-20355 Hamburg (Germany); Mazurenko, V. [Theoretical Physics and Applied Mathematic Department, Urals State Technical University, 620002, Mira street 19, Yekaterinburg (Russian Federation); Poteryaev, A. [Institute of Metal Physics, Russian Academy of Sciences, 620041 Yekaterinburg GSP-170 (Russian Federation); Lichtenstein, A. [I. Institut fuer Theoretische Physik, Universitaet Hamburg, Jungiusstrasse 9, D-20355 Hamburg (Germany)

    2010-07-15

    An intrinsic issue of the LDA + DMFT approach is the so called double counting of interaction terms. How to choose the double-counting potential in a manner that is both physically sound and consistent is unknown. We have conducted an extensive study of the charge-transfer system NiO in the LDA + DMFT framework using quantum Monte Carlo and exact diagonalization as impurity solvers. By explicitly treating the double-counting correction as an adjustable parameter we systematically investigated the effects of different choices for the double counting on the spectral function. Different methods for fixing the double counting can drive the result from Mott insulating to almost metallic. We propose a reasonable scheme for the determination of double-counting corrections for insulating systems.

  18. Gross alpha/beta analyses in water by liquid scintillation counting

    International Nuclear Information System (INIS)

    Wong, C.T.; Lawrence Livermore National Laboratory, CA; Soliman, V.M.; Perera, S.K.

    2005-01-01

    The standard procedure for analyzing gross alpha and gross beta in water is evaporation of the sample and radioactivity determination of the resultant solids by proportional counting. This technique lacks precision, and lacks sensitivity for samples with high total dissolved solids. Additionally, the analytical results are dependent on the choice of radionuclide calibration standard and the sample matrix. Direct analysis by liquid scintillation counting has the advantages of high counting efficiencies and minimal sample preparation time. However, due to the small sample aliquants used for analysis, long count times are necessary to reach required detection limits. The procedure proposed consists of evaporating a sample aliquant to dryness, dissolving the resultant solids in a small volume of dilute acid, followed by liquid scintillation counting to determine radioactivity. This procedure can handle sample aliquants containing up to 500 mg of dissolved solids. Various acids, scintillation cocktail mixtures, instrument discriminator settings, and regions of interest (ROI) were evaluated to determine optimum counting conditions. Precision is improved and matrix effects are reduced as compared to proportional counting. Tests indicate that this is a viable alternative to proportional counting for gross alpha and gross beta analyses of water samples. (author)

  19. Application of RI-counting method for posttraumatic CSF rhinorrhea

    International Nuclear Information System (INIS)

    Itoh, Takahiko; Terai, Yoshinori; Fujimoto, Shunichiro; Kawauchi, Masamitsu.

    1987-01-01

    Numerous techniques and procedures have been reported for the evaluation of CSF fistulas. Especially metrizamide CT cisternography and radioisotope (RI) cisternography have been reported to be reliable for localizing the site of CSF leakage, however, it has been difficult to diagnose the existence and the site of CSF leakages in some cases. RI-counting method, measuring RI-count of intranasal cotton pledgets after the intrathecal injection of RI ( 111 In-DTPA) is thought to be the most reliable method for detecting the presence of CSF leakage in these cases. We used six cotton pledgets which were inserted into upper, middle, and lower meatuses on both side. Because the site of pledgets with ghest RI-count has anatomical relationship to the opening of the paranasal sinus, we can surmise the leakage of dural defect and CSF leakage. RI counting method was applied to two patients in whom it was difficult to diagnose the presence of CSF leakage with other procedures. The patients were free in position for four hours after the intrathecal injection of RI, and in the prone position for 30 minutes before RI-counting of intranasal cotton pledgets. After measuring the RI-counts of six pledgets, the counts were compared with each other. The cotton pledget inserted into left middle meatus showed the highest count in both cases. From this result and finding of conventional skull tomography we speculated the site of CSF leakage to be frontal sinus or ethmoid sinus. Operation demonstrated the opening of dura into the frontal sinus in one case, and ethmoid sinus in another case. As mentioned above, RI-counting method has the advantages of detecting the existence and the site of CSF leakage. (author)

  20. Is It Counting, or Is It Adding?

    Science.gov (United States)

    Eisenhardt, Sara; Fisher, Molly H.; Thomas, Jonathan; Schack, Edna O.; Tassell, Janet; Yoder, Margaret

    2014-01-01

    The Common Core State Standards for Mathematics (CCSSI 2010) expect second grade students to "fluently add and subtract within 20 using mental strategies" (2.OA.B.2). Most children begin with number word sequences and counting approximations and then develop greater skill with counting. But do all teachers really understand how this…

  1. 2013 Kids Count in Colorado! Community Matters

    Science.gov (United States)

    Colorado Children's Campaign, 2013

    2013-01-01

    "Kids Count in Colorado!" is an annual publication of the Children's Campaign, providing state and county level data on child well-being factors including child health, education, and economic status. Since its first release 20 years ago, "Kids Count in Colorado!" has become the most trusted source for data and information on…

  2. Implementation of a nonlinear filter for online nuclear counting

    International Nuclear Information System (INIS)

    Coulon, R.; Dumazert, J.; Kondrasovs, V.; Normand, S.

    2016-01-01

    Nuclear counting is a challenging task for nuclear instrumentation because of the stochastic nature of radioactivity. Event counting has to be processed and filtered to determine a stable count rate value and perform variation monitoring of the measured event. An innovative approach for nuclear counting is presented in this study, improving response time and maintaining count rate stability. Some nonlinear filters providing a local maximum likelihood estimation of the signal have been recently developed, which have been tested and compared with conventional linear filters. A nonlinear filter thus developed shows significant performance in terms of response time and measurement precision. The filter also presents the specificity of easy embedment into digital signal processor (DSP) electronics based on field-programmable gate arrays (FPGA) or microcontrollers, compatible with real-time requirements. © 2001 Elsevier Science. All rights reserved. - Highlights: • An efficient approach based on nonlinear filtering has been implemented. • The hypothesis test provides a local maximum likelihood estimation of the count rate. • The filter ensures an optimal compromise between precision and response time.

  3. Automatic spark counting of alpha-tracks in plastic foils

    International Nuclear Information System (INIS)

    Somogyi, G.; Medveczky, L.; Hunyadi, I.; Nyako, B.

    1976-01-01

    The possibility of alpha-track counting by jumping spark counter in cellulose acetate and polycarbonate nuclear track detectors was studied. A theoretical treatment is presented which predicts the optimum residual thickness of the etched foils in which completely through-etched tracks (i.e. holes) can be obtained for alpha-particles of various energies and angles of incidence. In agreement with the theoretical prediction it is shown that a successful spark counting of alpha-tracks can be performed even in polycarbonate foils. Some counting characteristics, such as counting efficiency vs particle energy at various etched foil thicknesses, surface spark density produced by electric breakdowns in unexposed foils vs foil thickness, etc. have been determined. Special attention was given to the spark counting of alpha-tracks entering thin detectors at right angle. The applicability of the spark counting technique is demonstrated in angular distribution measurements of the 27 Al(p,α 0 ) 24 Mg nuclear reaction at Ep = 1899 keV resonance energy. For this study 15 μm thick Makrofol-G foils and a jumping spark counter of improved construction were used. (orig.) [de

  4. Low-priced, time-saving, reliable and stable LR-115 counting system

    International Nuclear Information System (INIS)

    Tchorz-Trzeciakiewicz, D.E.

    2015-01-01

    Nuclear alpha particles leave etches (tracks) when they hit the surface of a LR-115 detector. The density of these tracks is used to measure radon concentration. Counting these tracks by human sense is tedious and time-consuming procedure and may introduce counting error, whereas most available automatic and semiautomatic counting systems are expensive or complex. An uncomplicated, robust, reliable and stable counting system using freely available on the Internet software as Digimizer™ and PhotoScape was developed and proposed. The effectiveness of the proposed procedure was evaluated by comparing the amount of tracks counted by software with the amount of tracks counted manually for 223 detectors. The percentage error for each analysed detector was obtained as a difference between automatic and manual counts divided by manual count. For more than 97% of detectors, the percentage errors oscillated between −3% and 3%. - Highlights: • Semiautomatic, uncomplicated procedure was proposed to count the amount of alpha tracks. • Freely available software on the Internet used as alpha tracks counting system for LR-115. • LR-115 detectors used to measure radon concentration and radon exhalation rate

  5. Color quench correction for low level Cherenkov counting.

    Science.gov (United States)

    Tsroya, S; Pelled, O; German, U; Marco, R; Katorza, E; Alfassi, Z B

    2009-05-01

    The Cherenkov counting efficiency varies strongly with color quenching, thus correction curves must be used to obtain correct results. The external (152)Eu source of a Quantulus 1220 liquid scintillation counting (LSC) system was used to obtain a quench indicative parameter based on spectra area ratio. A color quench correction curve for aqueous samples containing (90)Sr/(90)Y was prepared. The main advantage of this method over the common spectra indicators is its usefulness also for low level Cherenkov counting.

  6. Road safety performance measures and AADT uncertainty from short-term counts.

    Science.gov (United States)

    Milligan, Craig; Montufar, Jeannette; Regehr, Jonathan; Ghanney, Bartholomew

    2016-12-01

    The objective of this paper is to enable better risk analysis of road safety performance measures by creating the first knowledge base on uncertainty surrounding annual average daily traffic (AADT) estimates when the estimates are derived by expanding short-term counts with the individual permanent counter method. Many road safety performance measures and performance models use AADT as an input. While there is an awareness that the input suffers from uncertainty, the uncertainty is not well known or accounted for. The paper samples data from a set of 69 permanent automatic traffic recorders in Manitoba, Canada, to simulate almost 2 million short-term counts over a five year period. These short-term counts are expanded to AADT estimates by transferring temporal information from a directly linked nearby permanent count control station, and the resulting AADT values are compared to a known reference AADT to compute errors. The impacts of five factors on AADT error are considered: length of short-term count, number of short-term counts, use of weekday versus weekend counts, distance from a count to its expansion control station, and the AADT at the count site. The mean absolute transfer error for expanded AADT estimates is 6.7%, and this value varied by traffic pattern group from 5% to 10.5%. Reference percentiles of the error distribution show that almost all errors are between -20% and +30%. Error decreases substantially by using a 48-h count instead of a 24-h count, and only slightly by using two counts instead of one. Weekday counts are superior to weekend counts, especially if the count is only 24h. Mean absolute transfer error increases with distance to control station (elasticity 0.121, p=0.001), and increases with AADT (elasticity 0.857, proad safety performance measures that use AADT as inputs. Analytical frameworks for such analysis exist but are infrequently used in road safety because the evidence base on AADT uncertainty is not well developed. Copyright

  7. Monitoring Milk Somatic Cell Counts

    Directory of Open Access Journals (Sweden)

    Gheorghe Şteţca

    2014-11-01

    Full Text Available The presence of somatic cells in milk is a widely disputed issue in milk production sector. The somatic cell counts in raw milk are a marker for the specific cow diseases such as mastitis or swollen udder. The high level of somatic cells causes physical and chemical changes to milk composition and nutritional value, and as well to milk products. Also, the mastitic milk is not proper for human consumption due to its contribution to spreading of certain diseases and food poisoning. According to these effects, EU Regulations established the maximum threshold of admitted somatic cells in raw milk to 400000 cells / mL starting with 2014. The purpose of this study was carried out in order to examine the raw milk samples provided from small farms, industrial type farms and milk processing units. There are several ways to count somatic cells in milk but the reference accepted method is the microscopic method described by the SR EN ISO 13366-1/2008. Generally samples registered values in accordance with the admissible limit. By periodical monitoring of the somatic cell count, certain technological process issues are being avoided and consumer’s health ensured.

  8. Graphite nodule count and size distribution in thin-walled ductile cast iron

    DEFF Research Database (Denmark)

    Pedersen, Karl Martin; Tiedje, Niels Skat

    2008-01-01

    Graphite nodule count and size distribution have been analysed in thin walled ductile cast iron. The 2D nodule counts have been converted into 3D nodule count by using Finite Difference Method (FDM). Particles having a diameter smaller than 5 µm should be neglected in the nodule count as these ar......Graphite nodule count and size distribution have been analysed in thin walled ductile cast iron. The 2D nodule counts have been converted into 3D nodule count by using Finite Difference Method (FDM). Particles having a diameter smaller than 5 µm should be neglected in the nodule count...... as these are inclusions and micro porosities that do not influence the solidification morphology. If there are many small graphite nodules as in thin walled castings only 3D nodule count calculated by FDM will give reliable results. 2D nodule count and 3D nodule count calculated by simple equations will give too low...

  9. Calorie count - fast food

    Science.gov (United States)

    ... GO About MedlinePlus Site Map FAQs Customer Support Health Topics Drugs & Supplements Videos & Tools Español You Are Here: Home → Medical Encyclopedia → Calorie count - fast food URL of this page: //medlineplus.gov/ency/patientinstructions/ ...

  10. A multiwire proportional counter for very high counting rates

    Energy Technology Data Exchange (ETDEWEB)

    Barbosa, A F; Guedes, G P [Centro Brasileiro de Pesquisas Fisicas (CBPF), Rio de Janeiro, RJ (Brazil); Tamura, E [Laboratorio Nacional de Luz Sincrotron (LNLS), Campinas, SP (Brazil); Pepe, I M; Oliveira, N B [Bahia Univ., Salvador, BA (Brazil). Inst. de Fisica

    1997-12-01

    Preliminary measurements in a proportional counter with two independently counting wires showed that counting rates up to 10{sup 6} counts/s per wire can be reached without critical loss in the true versus measured linearity relation. Results obtained with a detector containing 30 active wires (2 mm pitch) are presented. To each wire is associated a fast pre-amplifier and a discriminator channel. Global counting rates in excess to 10{sup 7} events/s are reported. Data acquisition systems are described for 1D (real time) and 2D (off-line) position sensitive detection systems. (author) 13 refs., 6 figs.

  11. Counting on fine motor skills: links between preschool finger dexterity and numerical skills.

    Science.gov (United States)

    Fischer, Ursula; Suggate, Sebastian P; Schmirl, Judith; Stoeger, Heidrun

    2017-10-26

    Finger counting is widely considered an important step in children's early mathematical development. Presumably, children's ability to move their fingers during early counting experiences to aid number representation depends in part on their early fine motor skills (FMS). Specifically, FMS should link to children's procedural counting skills through consistent repetition of finger-counting procedures. Accordingly, we hypothesized that (a) FMS are linked to early counting skills, and (b) greater FMS relate to conceptual counting knowledge (e.g., cardinality, abstraction, order irrelevance) via procedural counting skills (i.e., one-one correspondence and correctness of verbal counting). Preschool children (N = 177) were administered measures of procedural counting skills, conceptual counting knowledge, FMS, and general cognitive skills along with parent questionnaires on home mathematics and fine motor environment. FMS correlated with procedural counting skills and conceptual counting knowledge after controlling for cognitive skills, chronological age, home mathematics and FMS environments. Moreover, the relationship between FMS and conceptual counting knowledge was mediated by procedural counting skills. Findings suggest that FMS play a role in early counting and therewith conceptual counting knowledge. © 2017 John Wiley & Sons Ltd.

  12. Loss-Free Counting with Digital Signal Processors

    International Nuclear Information System (INIS)

    Markku Koskelo; Dave Hall; Martin Moslinger

    2000-01-01

    Loss-free-counting (LFC) techniques have frequently been used with traditional analog pulse processing systems to compensate for the time or pulses lost when a spectroscopy system is unavailable (busy) for processing an accepted pulse. With the availability of second-generation digital signal processing (DSP) electronics that offer a significantly improved performance for both high and low count rate applications, the LFC technique has been revisited. Specific attention was given to the high and ultra-high count rate behavior, using high-purity germanium (HPGe) detectors with both transistor reset preamplifiers (TRP) and conventional RC preamplifiers. The experiments conducted for this work show that the known LFC techniques further benefit when combined with modern DSP pulse shaping

  13. Computed neutron coincidence counting applied to passive waste assay

    Energy Technology Data Exchange (ETDEWEB)

    Bruggeman, M.; Baeten, P.; De Boeck, W.; Carchon, R. [Nuclear Research Centre, Mol (Belgium)

    1997-11-01

    Neutron coincidence counting applied for the passive assay of fissile material is generally realised with dedicated electronic circuits. This paper presents a software based neutron coincidence counting method with data acquisition via a commercial PC-based Time Interval Analyser (TIA). The TIA is used to measure and record all time intervals between successive pulses in the pulse train up to count-rates of 2 Mpulses/s. Software modules are then used to compute the coincidence count-rates and multiplicity related data. This computed neutron coincidence counting (CNCC) offers full access to all the time information contained in the pulse train. This paper will mainly concentrate on the application and advantages of CNCC for the non-destructive assay of waste. An advanced multiplicity selective Rossi-alpha method is presented and its implementation via CNCC demonstrated. 13 refs., 4 figs., 2 tabs.

  14. Computed neutron coincidence counting applied to passive waste assay

    International Nuclear Information System (INIS)

    Bruggeman, M.; Baeten, P.; De Boeck, W.; Carchon, R.

    1997-01-01

    Neutron coincidence counting applied for the passive assay of fissile material is generally realised with dedicated electronic circuits. This paper presents a software based neutron coincidence counting method with data acquisition via a commercial PC-based Time Interval Analyser (TIA). The TIA is used to measure and record all time intervals between successive pulses in the pulse train up to count-rates of 2 Mpulses/s. Software modules are then used to compute the coincidence count-rates and multiplicity related data. This computed neutron coincidence counting (CNCC) offers full access to all the time information contained in the pulse train. This paper will mainly concentrate on the application and advantages of CNCC for the non-destructive assay of waste. An advanced multiplicity selective Rossi-alpha method is presented and its implementation via CNCC demonstrated. 13 refs., 4 figs., 2 tabs

  15. A mobile-device based applications software for industrial gamma radiography

    International Nuclear Information System (INIS)

    Acharya, Rajesh V.; Mitra, Anant; Kumar, Saroj; Lakshminarayana, Y.; Walinjkar, Parag; Kumar, Umesh

    2013-12-01

    The paper discusses a mobile device based application software for performing calculations required in industrial film radiography using radioisotope sources. The application enables the user to find residual life of a radioactive source, saving multiple source details in the phone memory, exposure time calculation required in gamma radiography and running multiple countdown clocks for accurate and convenient counting of exposure time. The application is also able to provide vibrating and audio alarms when the countdown finishes, automatic SMS facility to multiple users informing details of low activity sources in custody and cordon-off distances for open-source radiography. The application has been developed to work under Android, I-phone (Apple), Blackberry (RIM), Windows, Symbian operating systems and J2ME enabled feature phones. A simplified version of this application with limited features runs on java enabled low-cost mobile phones and tablets. (author)

  16. High Reproducibility of ELISPOT Counts from Nine Different Laboratories

    Directory of Open Access Journals (Sweden)

    Srividya Sundararaman

    2015-01-01

    Full Text Available The primary goal of immune monitoring with ELISPOT is to measure the number of T cells, specific for any antigen, accurately and reproducibly between different laboratories. In ELISPOT assays, antigen-specific T cells secrete cytokines, forming spots of different sizes on a membrane with variable background intensities. Due to the subjective nature of judging maximal and minimal spot sizes, different investigators come up with different numbers. This study aims to determine whether statistics-based, automated size-gating can harmonize the number of spot counts calculated between different laboratories. We plated PBMC at four different concentrations, 24 replicates each, in an IFN-γ ELISPOT assay with HCMV pp65 antigen. The ELISPOT plate, and an image file of the plate was counted in nine different laboratories using ImmunoSpot® Analyzers by (A Basic Count™ relying on subjective counting parameters set by the respective investigators and (B SmartCount™, an automated counting protocol by the ImmunoSpot® Software that uses statistics-based spot size auto-gating with spot intensity auto-thresholding. The average coefficient of variation (CV for the mean values between independent laboratories was 26.7% when counting with Basic Count™, and 6.7% when counting with SmartCount™. Our data indicates that SmartCount™ allows harmonization of counting ELISPOT results between different laboratories and investigators.

  17. A Word Count of Modern Arabic Prose.

    Science.gov (United States)

    Landau, Jacob M.

    This book presents a word count of Arabic prose based on 60 twentieth-century Egyptian books. The text is divided into an alphabetical list and a word frequency list. This word count is intended as an aid in the: (1) writing of primers and the compilation of graded readers, (2) examination of the vocabulary selection of primers and readers…

  18. Alaska Steller sea lion Count Database (Non-pups)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This database contains counts of adult and juvenile (non-pup) Steller sea lions on rookeries and haulouts in Alaska made between 1904 and 2015. Non-pup counts have...

  19. Proposals of counting method for bubble detectors and their intercomparisons

    International Nuclear Information System (INIS)

    Ramalho, Eduardo; Silva, Ademir X.; Bellido, Luis F.; Facure, Alessandro; Pereira, Mario

    2009-01-01

    The study of neutron's spectrometry and dosimetry has become significantly easier due to relatively new devices called bubble detectors. Insensitive to gamma rays and composed by superheated emulsions, they still are subjects of many researches in Radiation Physics and Nuclear Engineering. In bubble detectors, either exposed to more intense neutron fields or for a long time, when more bubbles are produced, the statistical uncertainty during the dosimetric and spectrometric processes is reduced. A proposal of this nature is set up in this work, which presents ways to perform counting processes for bubble detectors and an updated proceeding to get the irradiated detectors' images in order to make the manual counting easier. Twelve BDS detectors were irradiated by RDS111 cyclotron from IEN's (Instituto de Engenharia Nuclear) and photographed using an assembly specially designed for this experiment. Counting was proceeded manually in a first moment; simultaneously, ImagePro was used in order to perform counting automatically. The bubble counting values, either manual or automatic, were compared and the time to get them and their difficult levels as well. After the bubble counting, the detectors' standardizes responses were calculated in both cases, according to BDS's manual and they were also compared. Among the results, the counting on these devices really becomes very hard at a large number of bubbles, besides higher variations in counting of many bubbles. Because of the good agreement between manual counting and the custom program, the last one revealed a good alternative in practical and economical levels. Despite the good results, the custom program needs of more adjustments in order to achieve more accuracy on higher counting on bubble detectors for neutron measurement applications. (author)

  20. Learning to count begins in infancy: evidence from 18 month olds' visual preferences.

    Science.gov (United States)

    Slaughter, Virginia; Itakura, Shoji; Kutsuki, Aya; Siegal, Michael

    2011-10-07

    We used a preferential looking paradigm to evaluate infants' preferences for correct versus incorrect counting. Infants viewed a video depicting six fish. In the correct counting sequence, a hand pointed to each fish in turn, accompanied by verbal counting up to six. In the incorrect counting sequence, the hand moved between two of the six fish while there was still verbal counting to six, thereby violating the one-to-one correspondence principle of correct counting. Experiment 1 showed that Australian 18 month olds, but not 15 month olds, significantly preferred to watch the correct counting sequence. In experiment 2, Australian infants' preference for correct counting disappeared when the count words were replaced by beeps or by Japanese count words. In experiment 3, Japanese 18 month olds significantly preferred the correct counting video only when counting was in Japanese. These results show that infants start to acquire the abstract principles governing correct counting prior to producing any counting behaviour.

  1. Improving EWMA Plans for Detecting Unusual Increases in Poisson Counts

    Directory of Open Access Journals (Sweden)

    R. S. Sparks

    2009-01-01

    adaptive exponentially weighted moving average (EWMA plan is developed for signalling unusually high incidence when monitoring a time series of nonhomogeneous daily disease counts. A Poisson transitional regression model is used to fit background/expected trend in counts and provides “one-day-ahead” forecasts of the next day's count. Departures of counts from their forecasts are monitored. The paper outlines an approach for improving early outbreak data signals by dynamically adjusting the exponential weights to be efficient at signalling local persistent high side changes. We emphasise outbreak signals in steady-state situations; that is, changes that occur after the EWMA statistic had run through several in-control counts.

  2. Upper limits from counting experiments with multiple pipelines

    International Nuclear Information System (INIS)

    Sutton, Patrick J

    2009-01-01

    In counting experiments, one can set an upper limit on the rate of a Poisson process based on a count of the number of events observed due to the process. In some experiments, one makes several counts of the number of events, using different instruments, different event detection algorithms or observations over multiple time intervals. We demonstrate how to generalize the classical frequentist upper limit calculation to the case where multiple counts of events are made over one or more time intervals using several (not necessarily independent) procedures. We show how different choices of the rank ordering of possible outcomes in the space of counts correspond to applying different levels of significance to the various measurements. We propose an ordering that is matched to the sensitivity of the different measurement procedures and show that in typical cases it gives stronger upper limits than other choices. As an example, we show how this method can be applied to searches for gravitational-wave bursts, where multiple burst-detection algorithms analyse the same data set, and demonstrate how a single combined upper limit can be set on the gravitational-wave burst rate.

  3. Pill counts and pill rental: unintended entrepreneurial opportunities.

    Science.gov (United States)

    Viscomi, Christopher M; Covington, Melissa; Christenson, Catherine

    2013-07-01

    Prescription opioid diversion and abuse are becoming increasingly prevalent in many regions of the world, particularly the United States. One method advocated to assess compliance with opioid prescriptions is occasional "pill counts." Shortly before a scheduled appointment, a patient is notified that they must bring in the unused portion of their opioid prescription. It has been assumed that if a patient has the correct number and strength of pills that should be present for that point in a prescription interval that they are unlikely to be selling or abusing their opioids. Two cases are presented where patients describe short term rental of opioids from illicit opioid dealers in order to circumvent pill counts. Pill renting appears to be an established method of circumventing pill counts. Pill counts do not assure non-diversion of opioids and provide additional cash flow to illicit opioid dealers.

  4. Big drop. [Decline in sperm counts from environmental pollution

    Energy Technology Data Exchange (ETDEWEB)

    Castleman, M.

    Statisticians at the University of Copenhagen have published a review of sperm-count studies carried out from 1938-1990. After controlling for such things as counting techniques and sexual activity, they found that average sperm counts have decreased 42% over the last 50 years. After eliminating possible causes such as heat and differences in counting techniques, the only plausible cause left was environmental pollution. This finding correlates with a study performed in 1979 which found abnormally high concentrations of such toxic pollutants as DDT and PCBs in semen. The Copenhagen study suggests that even at low levels of exposure, environmental pollution is having biological consequences.

  5. Fitting a distribution to miccrobial counts: making sense of zeros

    DEFF Research Database (Denmark)

    Ribeiro Duarte, Ana Sofia; Stockmarr, Anders; Nauta, Maarten

    and standard deviation) and the prevalence of contaminated food units (one minus the proportion of “true zeros”) from a set of microbial counts. By running the model with in silico generated concentration and count data, we could evaluate the performance of this method in terms of estimation of the three......Non-detects or left-censored results are inherent to the traditional methods of microbial enumeration in foods. Typically, a low concentration of microorganisms in a food unit goes undetected in plate counts or most probable number (MPN) counts, and produces “artificial zeros”. However......, these “artificial zeros” are only a share of the total number of zero counts resulting from a sample, as their number adds up to the number of “true zeros” resulting from uncontaminated units. In the process of fitting a probability distribution to microbial counts, “artificial” and “true” zeros are usually...

  6. Correction to the count-rate detection limit and sample/blank time-allocation methods

    International Nuclear Information System (INIS)

    Alvarez, Joseph L.

    2013-01-01

    A common form of count-rate detection limits contains a propagation of uncertainty error. This error originated in methods to minimize uncertainty in the subtraction of the blank counts from the gross sample counts by allocation of blank and sample counting times. Correct uncertainty propagation showed that the time allocation equations have no solution. This publication presents the correct form of count-rate detection limits. -- Highlights: •The paper demonstrated a proper method of propagating uncertainty of count rate differences. •The standard count-rate detection limits were in error. •Count-time allocation methods for minimum uncertainty were in error. •The paper presented the correct form of the count-rate detection limit. •The paper discussed the confusion between count-rate uncertainty and count uncertainty

  7. Modeling Repeated Count Data : Some Extensions of the Rasch Poisson Counts Model

    NARCIS (Netherlands)

    van Duijn, M.A.J.; Jansen, Margo

    1995-01-01

    We consider data that can be summarized as an N X K table of counts-for example, test data obtained by administering K tests to N subjects. The cell entries y(ij) are assumed to be conditionally independent Poisson-distributed random variables, given the NK Poisson intensity parameters mu(ij). The

  8. Two, four, six, eight... stop and count before it is too late! An audit on swab, needle and instrument counts in theatre.

    LENUS (Irish Health Repository)

    Donnelly, T.

    2014-07-01

    A concurrent audit was conducted over a four week period to determine if the counting of swabs, needles and instruments for surgery adhered to local policy and recommended guidelines. Data were collected on 30 abdominal surgical procedures. This audit highlighted failings in the count process. It identified poor communication within the multidisciplinary team. There needs to be an increased awareness about local policy, national and international guidelines regarding the counting of swabs, needles and instruments for all surgical procedures.

  9. Limit of sensitivity of low-background counting equipment

    International Nuclear Information System (INIS)

    Homann, S.G.

    1991-01-01

    The Hazards Control Department's Radiological Measurements Laboratory (RML) analyzes many types of sample media in support of the Laboratory's health and safety program. The Department has determined that the equation for the minimum limit of sensitivity, MDC(α,β) = 2.71 + 3.29 (r b t s ) 1/2 is also adequate for RML counting systems with very-low-background levels. This paper reviews the normal distribution case and address the special case of determining the limit of sensitivity of a counting system when the background count rate is well known and small. In the latter case, we must use an exact test procedure based on the binomial distribution. However, the error in using the normal distribution for calculating a detection system's limit of sensitivity is not significant even as the total observed number of counts approaches or equals zero. 2 refs., 4 figs

  10. An Automatic Car Counting System Using OverFeat Framework

    Directory of Open Access Journals (Sweden)

    Debojit Biswas

    2017-06-01

    Full Text Available Automatic car counting is an important component in the automated traffic system. Car counting is very important to understand the traffic load and optimize the traffic signals. In this paper, we implemented the Gaussian Background Subtraction Method and OverFeat Framework to count cars. OverFeat Framework is a combination of Convolution Neural Network (CNN and one machine learning classifier (like Support Vector Machines (SVM or Logistic Regression. With this study, we showed another possible application area for the OverFeat Framework. The advantages and shortcomings of the Background Subtraction Method and OverFeat Framework were analyzed using six individual traffic videos with different perspectives, such as camera angles, weather conditions and time of the day. In addition, we compared the two algorithms above with manual counting and a commercial software called Placemeter. The OverFeat Framework showed significant potential in the field of car counting with the average accuracy of 96.55% in our experiment.

  11. An Automatic Car Counting System Using OverFeat Framework.

    Science.gov (United States)

    Biswas, Debojit; Su, Hongbo; Wang, Chengyi; Blankenship, Jason; Stevanovic, Aleksandar

    2017-06-30

    Automatic car counting is an important component in the automated traffic system. Car counting is very important to understand the traffic load and optimize the traffic signals. In this paper, we implemented the Gaussian Background Subtraction Method and OverFeat Framework to count cars. OverFeat Framework is a combination of Convolution Neural Network (CNN) and one machine learning classifier (like Support Vector Machines (SVM) or Logistic Regression). With this study, we showed another possible application area for the OverFeat Framework. The advantages and shortcomings of the Background Subtraction Method and OverFeat Framework were analyzed using six individual traffic videos with different perspectives, such as camera angles, weather conditions and time of the day. In addition, we compared the two algorithms above with manual counting and a commercial software called Placemeter. The OverFeat Framework showed significant potential in the field of car counting with the average accuracy of 96.55% in our experiment.

  12. The Copenhagen primary care differential count (CopDiff) database

    DEFF Research Database (Denmark)

    Andersen, Christen Bertel L; Siersma, V.; Karlslund, W.

    2014-01-01

    BACKGROUND: The differential blood cell count provides valuable information about a person's state of health. Together with a variety of biochemical variables, these analyses describe important physiological and pathophysiological relations. There is a need for research databases to explore assoc...... the construction of the Copenhagen Primary Care Differential Count database as well as the distribution of characteristics of the population it covers and the variables that are recorded. Finally, it gives examples of its use as an inspiration to peers for collaboration.......BACKGROUND: The differential blood cell count provides valuable information about a person's state of health. Together with a variety of biochemical variables, these analyses describe important physiological and pathophysiological relations. There is a need for research databases to explore...... Practitioners' Laboratory has registered all analytical results since July 1, 2000. The Copenhagen Primary Care Differential Count database contains all differential blood cell count results (n=1,308,022) from July 1, 2000 to January 25, 2010 requested by general practitioners, along with results from analysis...

  13. Relationship between γ detection dead-time and count correction factor

    International Nuclear Information System (INIS)

    Wu Huailong; Zhang Jianhua; Chu Chengsheng; Hu Guangchun; Zhang Changfan; Hu Gen; Gong Jian; Tian Dongfeng

    2015-01-01

    The relationship between dead-time and count correction factor was investigated by using interference source for purpose of high γ activity measurement. The count rates maintain several 10 s"-"l with γ energy of 0.3-1.3 MeV for 10"4-10"5 Bq radioactive source. It is proved that the relationship between count loss and dead-time is unconcerned at various energy and various count intensities. The same correction formula can be used for any nuclide measurement. (authors)

  14. Manifold-Based Visual Object Counting.

    Science.gov (United States)

    Wang, Yi; Zou, Yuexian; Wang, Wenwu

    2018-07-01

    Visual object counting (VOC) is an emerging area in computer vision which aims to estimate the number of objects of interest in a given image or video. Recently, object density based estimation method is shown to be promising for object counting as well as rough instance localization. However, the performance of this method tends to degrade when dealing with new objects and scenes. To address this limitation, we propose a manifold-based method for visual object counting (M-VOC), based on the manifold assumption that similar image patches share similar object densities. Firstly, the local geometry of a given image patch is represented linearly by its neighbors using a predefined patch training set, and the object density of this given image patch is reconstructed by preserving the local geometry using locally linear embedding. To improve the characterization of local geometry, additional constraints such as sparsity and non-negativity are also considered via regularization, nonlinear mapping, and kernel trick. Compared with the state-of-the-art VOC methods, our proposed M-VOC methods achieve competitive performance on seven benchmark datasets. Experiments verify that the proposed M-VOC methods have several favorable properties, such as robustness to the variation in the size of training dataset and image resolution, as often encountered in real-world VOC applications.

  15. Limits of reliability for the measurement of integral count

    International Nuclear Information System (INIS)

    Erbeszkorn, L.

    1979-01-01

    A method is presented for exact and approximate calculation of reliability limits of measured nuclear integral count. The formulae are applicable in measuring conditions which assure the Poisson distribution of the counts. The coefficients of the approximate formulae for 90, 95, 98 and 99 per cent reliability levels are given. The exact reliability limits for 90 per cent reliability level are calculated up to 80 integral counts. (R.J.)

  16. Quantitative Compton suppression spectrometry at elevated counting rates

    International Nuclear Information System (INIS)

    Westphal, G.P.; Joestl, K.; Schroeder, P.; Lauster, R.; Hausch, E.

    1999-01-01

    For quantitative Compton suppression spectrometry the decrease of coincidence efficiency with counting rate should be made negligible to avoid a virtual increase of relative peak areas of coincident isomeric transitions with counting rate. To that aim, a separate amplifier and discriminator has been used for each of the eight segments of the active shield of a new well-type Compton suppression spectrometer, together with an optimized, minimum dead-time design of the anticoincidence logic circuitry. Chance coincidence losses in the Compton suppression spectrometer are corrected instrumentally by comparing the chance coincidence rate to the counting rate of the germanium detector in a pulse-counting Busy circuit (G.P. Westphal, J. Rad. Chem. 179 (1994) 55) which is combined with the spectrometer's LFC counting loss correction system. The normally not observable chance coincidence rate is reconstructed from the rates of germanium detector and scintillation detector in an auxiliary coincidence unit, after the destruction of true coincidence by delaying one of the coincidence partners. Quantitative system response has been tested in two-source measurements with a fixed reference source of 60 Co of 14 kc/s, and various samples of 137 Cs, up to aggregate counting rates of 180 kc/s for the well-type detector, and more than 1400 kc/s for the BGO shield. In these measurements, the net peak areas of the 1173.3 keV line of 60 Co remained constant at typical values of 37 000 with and 95 000 without Compton suppression, with maximum deviations from the average of less than 1.5%

  17. Tutorial on Using Regression Models with Count Outcomes Using R

    Directory of Open Access Journals (Sweden)

    A. Alexander Beaujean

    2016-02-01

    Full Text Available Education researchers often study count variables, such as times a student reached a goal, discipline referrals, and absences. Most researchers that study these variables use typical regression methods (i.e., ordinary least-squares either with or without transforming the count variables. In either case, using typical regression for count data can produce parameter estimates that are biased, thus diminishing any inferences made from such data. As count-variable regression models are seldom taught in training programs, we present a tutorial to help educational researchers use such methods in their own research. We demonstrate analyzing and interpreting count data using Poisson, negative binomial, zero-inflated Poisson, and zero-inflated negative binomial regression models. The count regression methods are introduced through an example using the number of times students skipped class. The data for this example are freely available and the R syntax used run the example analyses are included in the Appendix.

  18. More accurate thermal neutron coincidence counting technique

    International Nuclear Information System (INIS)

    Baron, N.

    1978-01-01

    Using passive thermal neutron coincidence counting techniques, the accuracy of nondestructive assays of fertile material can be improved significantly using a two-ring detector. It was shown how the use of a function of the coincidence count rate ring-ratio can provide a detector response rate that is independent of variations in neutron detection efficiency caused by varying sample moderation. Furthermore, the correction for multiplication caused by SF- and (α,n)-neutrons is shown to be separable into the product of a function of the effective mass of 240 Pu (plutonium correction) and a function of the (α,n) reaction probability (matrix correction). The matrix correction is described by a function of the singles count rate ring-ratio. This correction factor is empirically observed to be identical for any combination of PuO 2 powder and matrix materials SiO 2 and MgO because of the similar relation of the (α,n)-Q value and (α,n)-reaction cross section among these matrix nuclei. However the matrix correction expression is expected to be different for matrix materials such as Na, Al, and/or Li. Nevertheless, it should be recognized that for comparison measurements among samples of similar matrix content, it is expected that some function of the singles count rate ring-ratio can be defined to account for variations in the matrix correction due to differences in the intimacy of mixture among the samples. Furthermore the magnitude of this singles count rate ring-ratio serves to identify the contaminant generating the (α,n)-neutrons. Such information is useful in process control

  19. Pedestrian count estimation using texture feature with spatial distribution

    Directory of Open Access Journals (Sweden)

    Hongyu Hu

    2016-12-01

    Full Text Available We present a novel pedestrian count estimation approach based on global image descriptors formed from multi-scale texture features that considers spatial distribution. For regions of interest, local texture features are represented based on histograms of multi-scale block local binary pattern, which jointly constitute the feature vector of the whole image. Therefore, to achieve an effective estimation of pedestrian count, principal component analysis is used to reduce the dimension of the global representation features, and a fitting model between image global features and pedestrian count is constructed via support vector regression. The experimental result shows that the proposed method exhibits high accuracy on pedestrian count estimation and can be applied well in the real world.

  20. Sperm count. Do we need a new reference value?

    Science.gov (United States)

    Cardona Maya, Walter

    2010-03-01

    To evaluate the sperm count in fertile men, general population, and infertile men in different regions of the world. Sperm counts were recorded according to their fertility status, proven fertility, men recruited from an andrology/infertility clinic, or healthy men. The average of sperm count in the different studies is lower in infertile men that in fertile men (p>0.001) and in the general population (p>0.001). Based on this analysis the normal sperm count is about 65 million per mL. Using these reference value, only the 25% of the studies in infertile men are above this value, and the 75% studies with fertile men (>65 x 106 sperm/mL).

  1. Detectors for proton counting. Si-APD and scintillation detectors

    International Nuclear Information System (INIS)

    Kishimoto, Shunji

    2008-01-01

    Increased intensity of synchrotron radiation requests users to prepare photon pulse detectors having higher counting rates. As detectors for photon counting, silicon-avalanche photodiode (Si-APD) and scintillation detectors were chosen for the fifth series of detectors. Principle of photon detection by pulse and need of amplification function of the detector were described. Structure and working principle, high counting rate measurement system, bunch of electrons vs. counting rate, application example of NMR time spectroscopy measurement and comments for users were described for the Si-APD detector. Structure of scintillator and photomultiplier tube, characteristics of scintillator and performance of detector were shown for the NaI detector. Future development of photon pulse detectors was discussed. (T. Tanaka)

  2. Problems associated with scintillation counting of NaH14CO3 and gel suspension counting of Ba14CO3

    International Nuclear Information System (INIS)

    MacRae, J.C.; Wilson, S.

    1978-01-01

    Liquid NaH 14 CO 3 was assayed in emulsion-type (NE260 and Unisolve) and dioxan-based (NE250) scintillation cocktails contained in glass or polyethylene vials kept at 2 0 or 24-30 0 C. Different particle size ranges of standard Ba 14 CO 3 were assayed by gel suspension counting in Cabosil scintillation cocktail and in NE260 following solubilisation in EDTA-tetrasodium salt. Initial detectable activities of NaH 14 CO 3 in glass and polyethylene vials in NE250, NE260 and Unisolve were 97 and 96, 68 and 83, 71 and 89% of the true value respectively. Subsequent losses of activity over 7 days with the emulsion-type scintillators was greater from the polyethylene vials. Addition of phenylethylamine to the NE260 and Unisolve cocktails gave the true activity levels for all vials with no loss of activity over 6 days. When different particle size ranges of Standard Ba 14 CO 3 were suspended in Cabosil scintillation cocktail there was considerable variation in counting efficiency (77-88%) with little relationship between particle size and counting efficiency. The relationship between counting efficiency and channels ratio was not sufficiently precise for predictive purposes. Solubilisation of Ba 14 CO 3 in EDTA-tetrasodium salt gave similar counting efficiency and channels ratio values for all samples. (U.K.)

  3. Effects of lek count protocols on greater sage-grouse population trend estimates

    Science.gov (United States)

    Monroe, Adrian; Edmunds, David; Aldridge, Cameron L.

    2016-01-01

    Annual counts of males displaying at lek sites are an important tool for monitoring greater sage-grouse populations (Centrocercus urophasianus), but seasonal and diurnal variation in lek attendance may increase variance and bias of trend analyses. Recommendations for protocols to reduce observation error have called for restricting lek counts to within 30 minutes of sunrise, but this may limit the number of lek counts available for analysis, particularly from years before monitoring was widely standardized. Reducing the temporal window for conducting lek counts also may constrain the ability of agencies to monitor leks efficiently. We used lek count data collected across Wyoming during 1995−2014 to investigate the effect of lek counts conducted between 30 minutes before and 30, 60, or 90 minutes after sunrise on population trend estimates. We also evaluated trends across scales relevant to management, including statewide, within Working Group Areas and Core Areas, and for individual leks. To further evaluate accuracy and precision of trend estimates from lek count protocols, we used simulations based on a lek attendance model and compared simulated and estimated values of annual rate of change in population size (λ) from scenarios of varying numbers of leks, lek count timing, and count frequency (counts/lek/year). We found that restricting analyses to counts conducted within 30 minutes of sunrise generally did not improve precision of population trend estimates, although differences among timings increased as the number of leks and count frequency decreased. Lek attendance declined >30 minutes after sunrise, but simulations indicated that including lek counts conducted up to 90 minutes after sunrise can increase the number of leks monitored compared to trend estimates based on counts conducted within 30 minutes of sunrise. This increase in leks monitored resulted in greater precision of estimates without reducing accuracy. Increasing count

  4. Single electron counting using a dual MCP assembly

    International Nuclear Information System (INIS)

    Yang, Yuzhen; Liu, Shulin; Zhao, Tianchi; Yan, Baojun; Wang, Peiliang; Yu, Yang; Lei, Xiangcui; Yang, Luping; Wen, Kaile; Qi, Ming

    2016-01-01

    The gain, pulse height resolution and peak-to-valley ratio of single electrons detected by using a Chevron configured Microchannel Plate (MCP) assembly are studied. The two MCPs are separated by a 280 µm gap and are biased by four electrodes. The purpose of the study is to determine the optimum bias voltage arrangements for single electron counting. By comparing the results of various bias voltage combinations, we conclude that good performance for the electron counting can be achieved by operating the MCP assembly in saturation mode. In addition, by applying a small reverse bias voltage across the gap while adjusting the bias voltages of the MCPs, optimum performance of electron counting can be obtained. - Highlights: • Dual MCPs assembly with four electrodes using different voltage combinations has been investigated for single electron counting. • Both the MCP voltages and the gap voltage can affect the gain, pulse height resolution and P/V ratio. • A high gain of the first stage MCP, a saturation mode of the second stage MCP and an appropriately reverse gap voltage can improve the resolution greatly. • The optimum voltage arrangements is significant for the design of MCP detectors in single electron counting applications.

  5. Real-time passenger counting by active linear cameras

    Science.gov (United States)

    Khoudour, Louahdi; Duvieubourg, Luc; Deparis, Jean-Pierre

    1996-03-01

    The companies operating subways are very much concerned with counting the passengers traveling through their transport systems. One of the most widely used systems for counting passengers consists of a mechanical gate equipped with a counter. However, such simple systems are not able to count passengers jumping above the gates. Moreover, passengers carrying large luggage or bags may meet some difficulties when going through such gates. The ideal solution is a contact-free counting system that would bring more comfort of use for the passengers. For these reasons, we propose to use a video processing system instead of these mechanical gates. The optical sensors discussed in this paper offer several advantages including well defined detection areas, fast response time and reliable counting capability. A new technology has been developed and tested, based on linear cameras. Preliminary results show that this system is very efficient when the passengers crossing the optical gate are well separated. In other cases, such as in compact crowd conditions, reasonable accuracy has been demonstrated. These results are illustrated by means of a number of sequences shot in field conditions. It is our belief that more precise measurements could be achieved, in the case of compact crowd, by other algorithms and acquisition techniques of the line images that we are presently developing.

  6. Spark counting technique with an aluminium oxide film

    International Nuclear Information System (INIS)

    Kawai, H.; Koga, T.; Morishima, H.; Niwa, T.; Nishiwaki, Y.

    1980-01-01

    Automatic spark counting of etch-pits on a polycarbonate film produced by nuclear fission fragments is now used for neutron monitoring in several countries. A method was developed using an aluminium oxide film instead of a polycarbonate as the neutron detector. Aluminium oxide films were prepared as follows: A cleaned aluminium plate as an anode and a nickel plate as a cathode were immersed in dilute sulfuric acid solution and electric current flowed between the electrodes at 12degC for 10-30 minutes. Electric current density was about 10 mA/cm 2 . The aluminium plate was then kept in boiling water for 10-30 minutes for sealing. The thickness of the aluminium oxide layer formed was about 1μm. The aluminium plate attached to a plate of suitable fissionable material, such as uranium or thorium, was irradiated with neutrons and set in a usual spark counter for fission track counting. One electrode was the aluminium plate and the other was an aluminized polyester sheet. Sparked pulses were counted with a usual scaler. The advantage of using spark counting with an aluminium oxide film for neutron monitoring is rapid measurement of neutron exposure, since chemical etching which is indispensable for spark counting with a polycarbonate detector film, is not needed. (H.K.)

  7. Fluorescent Biosensors Based on Single-Molecule Counting.

    Science.gov (United States)

    Ma, Fei; Li, Ying; Tang, Bo; Zhang, Chun-Yang

    2016-09-20

    Biosensors for highly sensitive, selective, and rapid quantification of specific biomolecules make great contributions to biomedical research, especially molecular diagnostics. However, conventional methods for biomolecular assays often suffer from insufficient sensitivity and poor specificity. In some case (e.g., early disease diagnostics), the concentration of target biomolecules is too low to be detected by these routine approaches, and cumbersome procedures are needed to improve the detection sensitivity. Therefore, there is an urgent need for rapid and ultrasensitive analytical tools. In this respect, single-molecule fluorescence approaches may well satisfy the requirement and hold promising potential for the development of ultrasensitive biosensors. Encouragingly, owing to the advances in single-molecule microscopy and spectroscopy over past decades, the detection of single fluorescent molecule comes true, greatly boosting the development of highly sensitive biosensors. By in vitro/in vivo labeling of target biomolecules with proper fluorescent tags, the quantification of certain biomolecule at the single-molecule level is achieved. In comparison with conventional ensemble measurements, single-molecule detection-based analytical methods possess the advantages of ultrahigh sensitivity, good selectivity, rapid analysis time, and low sample consumption. Consequently, single-molecule detection may be potentially employed as an ideal analytical approach to quantify low-abundant biomolecules with rapidity and simplicity. In this Account, we will summarize our efforts for developing a series of ultrasensitive biosensors based on single-molecule counting. Single-molecule counting is a member of single-molecule detection technologies and may be used as a very simple and ultrasensitive method to quantify target molecules by simply counting the individual fluorescent bursts. In the fluorescent sensors, the signals of target biomolecules may be translated to the

  8. An Automatic Car Counting System Using OverFeat Framework

    OpenAIRE

    Biswas, Debojit; Su, Hongbo; Wang, Chengyi; Blankenship, Jason; Stevanovic, Aleksandar

    2017-01-01

    Automatic car counting is an important component in the automated traffic system. Car counting is very important to understand the traffic load and optimize the traffic signals. In this paper, we implemented the Gaussian Background Subtraction Method and OverFeat Framework to count cars. OverFeat Framework is a combination of Convolution Neural Network (CNN) and one machine learning classifier (like Support Vector Machines (SVM) or Logistic Regression). With this study, we showed another poss...

  9. Counting SET-free sets

    OpenAIRE

    Harman, Nate

    2016-01-01

    We consider the following counting problem related to the card game SET: How many $k$-element SET-free sets are there in an $n$-dimensional SET deck? Through a series of algebraic reformulations and reinterpretations, we show the answer to this question satisfies two polynomiality conditions.

  10. Automation system for optical counting of nuclear tracks

    Energy Technology Data Exchange (ETDEWEB)

    Boulyga, S.F.; Boulyga, E.G.; Lomonosova, E.M.; Zhuk, I.V

    1999-06-01

    An automation system consisting of the microscope, video camera and Pentium PC with frame recorder was created. The system provides counting of nuclear tracks on the SSNTD surface with a resolution of 752 x 582 points, determination of the surface area and main axis of the track. The pattern recognition program was developed for operation in Windows 3.1 (or higher) ensuring a convenient interface with the user. In a comparison of the results on automatic track counting with the more accurate hand mode it was shown that the program enables the tracks to be detected even on images with a rather high noise level. It ensures a high accuracy of track counting being comparable with the accuracy of manual counting for densities of tracks in the range of up to 2{center_dot}10{sup 5} tracks/cm{sup 2}. The automatic system was applied in the experimental investigation of uranium and transuranium elements.

  11. Automation system for optical counting of nuclear tracks

    International Nuclear Information System (INIS)

    Boulyga, S.F.; Boulyga, E.G.; Lomonosova, E.M.; Zhuk, I.V.

    1999-01-01

    An automation system consisting of the microscope, video camera and Pentium PC with frame recorder was created. The system provides counting of nuclear tracks on the SSNTD surface with a resolution of 752 x 582 points, determination of the surface area and main axis of the track. The pattern recognition program was developed for operation in Windows 3.1 (or higher) ensuring a convenient interface with the user. In a comparison of the results on automatic track counting with the more accurate hand mode it was shown that the program enables the tracks to be detected even on images with a rather high noise level. It ensures a high accuracy of track counting being comparable with the accuracy of manual counting for densities of tracks in the range of up to 2·10 5 tracks/cm 2 . The automatic system was applied in the experimental investigation of uranium and transuranium elements

  12. Automation system for optical counting of nuclear tracks

    CERN Document Server

    Boulyga, S F; Lomonosova, E M; Zhuk, I V

    1999-01-01

    An automation system consisting of the microscope, video camera and Pentium PC with frame recorder was created. The system provides counting of nuclear tracks on the SSNTD surface with a resolution of 752 x 582 points, determination of the surface area and main axis of the track. The pattern recognition program was developed for operation in Windows 3.1 (or higher) ensuring a convenient interface with the user. In a comparison of the results on automatic track counting with the more accurate hand mode it was shown that the program enables the tracks to be detected even on images with a rather high noise level. It ensures a high accuracy of track counting being comparable with the accuracy of manual counting for densities of tracks in the range of up to 2 centre dot 10 sup 5 tracks/cm sup 2. The automatic system was applied in the experimental investigation of uranium and transuranium elements.

  13. Relationship of milking rate to somatic cell count.

    Science.gov (United States)

    Brown, C A; Rischette, S J; Schultz, L H

    1986-03-01

    Information on milking rate, monthly bucket somatic cell counts, mastitis treatment, and milk production was obtained from 284 lactations of Holstein cows separated into three lactation groups. Significant correlations between somatic cell count (linear score) and other parameters included production in lactation 1 (-.185), production in lactation 2 (-.267), and percent 2-min milk in lactation 2 (.251). Somatic cell count tended to increase with maximum milking rate in all lactations, but correlations were not statistically significant. Twenty-nine percent of cows with milking rate measurements were treated for clinical mastitis. Treated cows in each lactation group produced less milk than untreated cows. In the second and third lactation groups, treated cows had a shorter total milking time and a higher percent 2-min milk than untreated cows, but differences were not statistically significant. Overall, the data support the concept that faster milking cows tend to have higher cell counts and more mastitis treatments, particularly beyond first lactation. However, the magnitude of the relationship was small.

  14. An automated approach for annual layer counting in ice cores

    Science.gov (United States)

    Winstrup, M.; Svensson, A.; Rasmussen, S. O.; Winther, O.; Steig, E.; Axelrod, A.

    2012-04-01

    The temporal resolution of some ice cores is sufficient to preserve seasonal information in the ice core record. In such cases, annual layer counting represents one of the most accurate methods to produce a chronology for the core. Yet, manual layer counting is a tedious and sometimes ambiguous job. As reliable layer recognition becomes more difficult, a manual approach increasingly relies on human interpretation of the available data. Thus, much may be gained by an automated and therefore objective approach for annual layer identification in ice cores. We have developed a novel method for automated annual layer counting in ice cores, which relies on Bayesian statistics. It uses algorithms from the statistical framework of Hidden Markov Models (HMM), originally developed for use in machine speech recognition. The strength of this layer detection algorithm lies in the way it is able to imitate the manual procedures for annual layer counting, while being based on purely objective criteria for annual layer identification. With this methodology, it is possible to determine the most likely position of multiple layer boundaries in an entire section of ice core data at once. It provides a probabilistic uncertainty estimate of the resulting layer count, hence ensuring a proper treatment of ambiguous layer boundaries in the data. Furthermore multiple data series can be incorporated to be used at once, hence allowing for a full multi-parameter annual layer counting method similar to a manual approach. In this study, the automated layer counting algorithm has been applied to data from the NGRIP ice core, Greenland. The NGRIP ice core has very high temporal resolution with depth, and hence the potential to be dated by annual layer counting far back in time. In previous studies [Andersen et al., 2006; Svensson et al., 2008], manual layer counting has been carried out back to 60 kyr BP. A comparison between the counted annual layers based on the two approaches will be presented

  15. Counting Triangles to Sum Squares

    Science.gov (United States)

    DeMaio, Joe

    2012-01-01

    Counting complete subgraphs of three vertices in complete graphs, yields combinatorial arguments for identities for sums of squares of integers, odd integers, even integers and sums of the triangular numbers.

  16. Mutual interference of alpha and beta signals in counting

    International Nuclear Information System (INIS)

    Zhang Fengxiang; Ren Wei; Tang Shaohua; Han Suping; Du Xiangyang.

    1993-01-01

    When multi-wire proportional counters are used for monitoring of mixed contamination of α and β radioactivity, both of the signals should be distinguished as far as possible from requirement of radiation protection. The rules provided by the recommendation standard of International Electrotechnical Committee (IEC) and the national standard of China indicate: For fixed personal surface contamination monitoring assembly, the response of the α-counting channel to β events should be smaller than 1% of response of the α-counting channel to α events, and the response of β-counting channel to β events should be smaller than that of the response of α-counting channel to the same events. To distinguish one kind of signal from another, amplitude discrimination method is used usually. (3 figs)

  17. A new stratification of mourning dove call-count routes

    Science.gov (United States)

    Blankenship, L.H.; Humphrey, A.B.; MacDonald, D.

    1971-01-01

    The mourning dove (Zenaidura macroura) call-count survey is a nationwide audio-census of breeding mourning doves. Recent analyses of the call-count routes have utilized a stratification based upon physiographic regions of the United States. An analysis of 5 years of call-count data, based upon stratification using potential natural vegetation, has demonstrated that this uew stratification results in strata with greater homogeneity than the physiographic strata, provides lower error variance, and hence generates greatet precision in the analysis without an increase in call-count routes. Error variance was reduced approximately 30 percent for the contiguous United States. This indicates that future analysis based upon the new stratification will result in an increased ability to detect significant year-to-year changes.

  18. Metal ion levels and lymphocyte counts

    DEFF Research Database (Denmark)

    Penny, Jeannette Ø; Varmarken, Jens-Erik; Ovesen, Ole

    2013-01-01

    BACKGROUND AND PURPOSE: Wear particles from metal-on-metal arthroplasties are under suspicion for adverse effects both locally and systemically, and the DePuy ASR Hip Resurfacing System (RHA) has above-average failure rates. We compared lymphocyte counts in RHA and total hip arthroplasty (THA) an....../ppb. INTERPRETATION: Circulating T-lymphocyte levels may decline after surgery, regardless of implant type. Metal ions-particularly cobalt-may have a general depressive effect on T- and B-lymphocyte levels. Registered with ClinicalTrials.gov under # NCT01113762.......BACKGROUND AND PURPOSE: Wear particles from metal-on-metal arthroplasties are under suspicion for adverse effects both locally and systemically, and the DePuy ASR Hip Resurfacing System (RHA) has above-average failure rates. We compared lymphocyte counts in RHA and total hip arthroplasty (THA....... RESULTS: The T-lymphocyte counts for both implant types declined over the 2-year period. This decline was statistically significant for CD3(+)CD8(+) in the THA group, with a regression coefficient of -0.04 × 10(9)cells/year (95% CI: -0.08 to -0.01). Regression analysis indicated a depressive effect...

  19. Theory and application of Cerenkov counting

    Energy Technology Data Exchange (ETDEWEB)

    Ross, H.H.

    1976-01-01

    The production of Cherenkov radiation by charged particles moving through a transparent medium (the Cherenkov generator) is a strictly physical process that is virtually independent of the chemistry of the medium. Thus, it is possible to calculate easily all of the important parameters of the Cherenkov process such as excitation threshold, emission intensity, spectral distribution, directional characteristics, and time response. The results of many of these physical effects are unknown in conventional liquid scintillation spectroscopy and, therefore, many unique assay techniques have been developed as a result of their consideration. This paper discusses the theoretical basis of the Cherenkov process, explores the unusual characteristics of the phenomenon, and demonstrates how these unusual characteristics can be used to develop equally unusual counting methodologies. Particular emphasis is directed toward an analysis of published data (obtained with conventional liquid scintillation instrumentation) that would be difficult or impossible to obtain with other counting techniques. Also discussed is a new type of sample vial that uses an isolated waveshifting system. The device was specifically designed for Cherenkov counting.

  20. Absolute nuclear material assay using count distribution (LAMBDA) space

    Science.gov (United States)

    Prasad, Manoj K [Pleasanton, CA; Snyderman, Neal J [Berkeley, CA; Rowland, Mark S [Alamo, CA

    2012-06-05

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  1. Sperm motility and morphology as changing parameters linked to sperm count variations.

    OpenAIRE

    Dua A; Vaidya S

    1996-01-01

    Variations in semen analyses of 177 males over a 1 year period were assessed. The average means of total counts, motility, morphology, total motile count and non-motile % were determined for 5 classes of patients ranging from azoospermic to normospermic. Positive relationships between a falling sperm count, a decrease in motility and total motile counts were seen. Also, increasingly, abnormal forms were found with lower sperm counts.

  2. Platelet count is associated with cardiovascular disease, cancer and mortality

    DEFF Research Database (Denmark)

    Vinholt, P J; Hvas, A M; Frederiksen, H

    2016-01-01

    count (100-450×10(9)/L) and mortality, development of future cardiovascular disease (myocardial infarction, ischaemic stroke, or peripheral vascular disease), venous thromboembolism, bleeding or cancer in the general population. MATERIAL AND METHODS: We conducted a register-based cohort study of 21......,252 adults (≥20years) from the Danish General Suburban Population Study (GESUS). Laboratory results from GESUS were linked to information from national registers regarding morbidity and death. Cox proportional hazard regression was conducted with adjustment for age, sex, smoking status, haemoglobin......, leukocyte count, C-reactive protein and Charlson comorbidity index. RESULTS: We found a U-shaped relationship between mortality and platelet count. Mortality was significantly increased for platelet count 300×10(9)/L. When categorizing platelet count using the interval 201-250×10(9)/L...

  3. A study of cellular counting to determine minimum thresholds for adequacy for liquid-based cervical cytology using a survey and counting protocol.

    Science.gov (United States)

    Kitchener, Henry C; Gittins, Matthew; Desai, Mina; Smith, John H F; Cook, Gary; Roberts, Chris; Turnbull, Lesley

    2015-03-01

    Liquid-based cytology (LBC) for cervical screening would benefit from laboratory practice guidelines that define specimen adequacy for reporting of slides. The evidence base required to define cell adequacy should incorporate both ThinPrep™ (TP; Hologic, Inc., Bedford, MA, USA) and SurePath™ (SP; BD Diagnostics, Burlington, NC, USA), the two LBC systems used in the UK cervical screening programmes. The objectives of this study were to determine (1) current practice for reporting LBC in England, Wales and Scotland, (2) a reproducible method for cell counting, (3) the cellularity of slides classified as inadequate, negative or abnormal and (4) the impact of varying cellularity on the likelihood of detecting cytological abnormalities. The study involved four separate arms to pursue each of the four objectives. (1) A questionnaire survey of laboratories was conducted. (2) A standard counting protocol was developed and used by three experienced cytopathologists to determine a reliable and reproducible cell counting method. (3) Slide sets which included a range of cytological abnormalities were each sent to three laboratories for cell counting to study the correlation between cell counts and reported cytological outcomes. (4) Dilution of LBC samples by fluid only (unmixed) or by dilution with a sample containing normal cells (mixed) was performed to study the impact on reporting of reducing either the total cell count or the relative proportion of abnormal to normal cells. The study was conducted within the cervical screening programmes in England, Wales and Scotland, using routinely obtained cervical screening samples, and in 56 participating NHS cervical cytology laboratories. The study involved only routinely obtained cervical screening samples. There was no clinical intervention. The main outcome measures were (1) reliability of counting method, (2) correlation of reported cytology grades with cellularity and (3) levels of detection of abnormal cells in

  4. Study on advancement of in vivo counting using mathematical simulation

    Energy Technology Data Exchange (ETDEWEB)

    Kinase, Sakae [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2003-05-01

    To obtain an assessment of the committed effective dose, individual monitoring for the estimation of intakes of radionuclides is required. For individual monitoring of exposure to intakes of radionuclides, direct measurement of radionuclides in the body - in vivo counting- is very useful. To advance in a precision in vivo counting which fulfills the requirements of ICRP 1990 recommendations, some problems, such as the investigation of uncertainties in estimates of body burdens by in vivo counting, and the selection of the way to improve the precision, have been studied. In the present study, a calibration technique for in vivo counting application using Monte Carlo simulation was developed. The advantage of the technique is that counting efficiency can be obtained for various shapes and sizes that are very difficult to change for phantoms. To validate the calibration technique, the response functions and counting efficiencies of a whole-body counter installed in JAERI were evaluated using the simulation and measurements. Consequently, the calculations are in good agreement with the measurements. The method for the determination of counting efficiency curves as a function of energy was developed using the present technique and a physiques correction equation was derived from the relationship between parameters of correction factor and counting efficiencies of the JAERI whole-body counter. The uncertainties in body burdens of {sup 137}Cs estimated with the JAERI whole-body counter were also investigated using the Monte Carlo simulation and measurements. It was found that the uncertainties of body burdens estimated with the whole-body counter are strongly dependent on various sources of uncertainty such as radioactivity distribution within the body and counting statistics. Furthermore, the evaluation method of the peak efficiencies of a Ge semi-conductor detector was developed by Monte Carlo simulation for optimum arrangement of Ge semi-conductor detectors for

  5. Differences in meristic counts of the genus Clarias (pisces: clariidae ...

    African Journals Online (AJOL)

    Specific differences in meristic counts were exhibited in both the anal fin ray count and the vertebral count in the clariids of Anambra rver, Nigeria. There was a close numerical relationship between the number of anal fin rays and the number of vertebrae. The present study further justifies the taxonomic importance of anal fin ...

  6. Validation of an automated colony counting system for group A Streptococcus.

    Science.gov (United States)

    Frost, H R; Tsoi, S K; Baker, C A; Laho, D; Sanderson-Smith, M L; Steer, A C; Smeesters, P R

    2016-02-08

    The practice of counting bacterial colony forming units on agar plates has long been used as a method to estimate the concentration of live bacteria in culture. However, due to the laborious and potentially error prone nature of this measurement technique, an alternative method is desirable. Recent technologic advancements have facilitated the development of automated colony counting systems, which reduce errors introduced during the manual counting process and recording of information. An additional benefit is the significant reduction in time taken to analyse colony counting data. Whilst automated counting procedures have been validated for a number of microorganisms, the process has not been successful for all bacteria due to the requirement for a relatively high contrast between bacterial colonies and growth medium. The purpose of this study was to validate an automated counting system for use with group A Streptococcus (GAS). Twenty-one different GAS strains, representative of major emm-types, were selected for assessment. In order to introduce the required contrast for automated counting, 2,3,5-triphenyl-2H-tetrazolium chloride (TTC) dye was added to Todd-Hewitt broth with yeast extract (THY) agar. Growth on THY agar with TTC was compared with growth on blood agar and THY agar to ensure the dye was not detrimental to bacterial growth. Automated colony counts using a ProtoCOL 3 instrument were compared with manual counting to confirm accuracy over the stages of the growth cycle (latent, mid-log and stationary phases) and in a number of different assays. The average percentage differences between plating and counting methods were analysed using the Bland-Altman method. A percentage difference of ±10 % was determined as the cut-off for a critical difference between plating and counting methods. All strains measured had an average difference of less than 10 % when plated on THY agar with TTC. This consistency was also observed over all phases of the growth

  7. Statistical tests to compare motif count exceptionalities

    Directory of Open Access Journals (Sweden)

    Vandewalle Vincent

    2007-03-01

    Full Text Available Abstract Background Finding over- or under-represented motifs in biological sequences is now a common task in genomics. Thanks to p-value calculation for motif counts, exceptional motifs are identified and represent candidate functional motifs. The present work addresses the related question of comparing the exceptionality of one motif in two different sequences. Just comparing the motif count p-values in each sequence is indeed not sufficient to decide if this motif is significantly more exceptional in one sequence compared to the other one. A statistical test is required. Results We develop and analyze two statistical tests, an exact binomial one and an asymptotic likelihood ratio test, to decide whether the exceptionality of a given motif is equivalent or significantly different in two sequences of interest. For that purpose, motif occurrences are modeled by Poisson processes, with a special care for overlapping motifs. Both tests can take the sequence compositions into account. As an illustration, we compare the octamer exceptionalities in the Escherichia coli K-12 backbone versus variable strain-specific loops. Conclusion The exact binomial test is particularly adapted for small counts. For large counts, we advise to use the likelihood ratio test which is asymptotic but strongly correlated with the exact binomial test and very simple to use.

  8. Complete Blood Count (For Parents)

    Science.gov (United States)

    ... Kids Deal With Injections and Blood Tests Blood Culture Anemia Blood Test: Basic Metabolic Panel (BMP) Blood Test: Hemoglobin Basic Blood Chemistry Tests Word! Complete Blood Count (CBC) Medical Tests and Procedures ( ...

  9. Sperm motility and morphology as changing parameters linked to sperm count variations.

    Directory of Open Access Journals (Sweden)

    Dua A

    1996-10-01

    Full Text Available Variations in semen analyses of 177 males over a 1 year period were assessed. The average means of total counts, motility, morphology, total motile count and non-motile % were determined for 5 classes of patients ranging from azoospermic to normospermic. Positive relationships between a falling sperm count, a decrease in motility and total motile counts were seen. Also, increasingly, abnormal forms were found with lower sperm counts.

  10. CalCOFI Larvae Counts, Scientific Names CI to CO

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  11. CalCOFI Larvae Counts, Scientific Names DH to EC

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  12. CalCOFI Larvae Counts, Scientific Names TF to U

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  13. CalCOFI Larvae Counts, Scientific Names HJ to ID

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  14. CalCOFI Larvae Counts, Scientific Names AN to AR

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  15. CalCOFI Larvae Counts, Scientific Names SJ to ST

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  16. CalCOFI Larvae Counts, Scientific Names CP to DE

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  17. CalCOFI Larvae Counts, Scientific Names C to CE

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  18. CalCOFI Larvae Counts, Scientific Names EV to GN

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  19. CalCOFI Larvae Counts, Scientific Names V to Z

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  20. CalCOFI Larvae Counts, Scientific Names ED to EU

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  1. CalCOFI Larvae Counts, Scientific Names SD to SI

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  2. CalCOFI Larvae Counts, Scientific Names MB to MO

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  3. CalCOFI Larvae Counts, Scientific Names LJ to MA

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  4. CalCOFI Larvae Counts, Scientific Names AS to BA

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  5. CalCOFI Larvae Counts, Scientific Names SB to SC

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  6. CalCOFI Larvae Counts, Scientific Names MP to NA

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  7. CalCOFI Larvae Counts, Scientific Names SU to TE

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  8. CalCOFI Larvae Counts, Scientific Names PL to PO

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  9. CalCOFI Larvae Counts, Scientific Names IE to LA

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  10. CalCOFI Larvae Counts, Scientific Names A to AM

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  11. CalCOFI Larvae Counts, Scientific Names HB to HI

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  12. CalCOFI Larvae Counts, Scientific Names OM to OX

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  13. CalCOFI Larvae Counts, Scientific Names Q to SA

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  14. CalCOFI Larvae Counts, Scientific Names PP to PZ

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  15. CalCOFI Larvae Counts, Scientific Names GO to HA

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  16. CalCOFI Larvae Counts, Scientific Names NB to OL

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  17. CalCOFI Larvae Counts, Scientific Names LB to LI

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  18. CalCOFI Larvae Counts, Scientific Names BCE to BZ

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  19. CalCOFI Larvae Counts, Scientific Names CD to CH

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  20. CalCOFI Larvae Counts, Scientific Names OY to PI

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  1. Point Count Length and Detection of Forest Neotropical Migrant Birds

    Science.gov (United States)

    Deanna K. Dawson; David R. Smith; Chandler S. Robbins

    1995-01-01

    Comparisons of bird abundances among years or among habitats assume that the rates at which birds are detected and counted are constant within species. We use point count data collected in forests of the Mid-Atlantic states to estimate detection probabilities for Neotropical migrant bird species as a function of count length. For some species, significant differences...

  2. Men of physics Count Rumford on the nature of heat

    CERN Document Server

    Brown, Sanborn C

    2013-01-01

    Men of Physics: Benjamin Thompson—Count Rumford: Count Rumford on the Nature of Heat presents the life and works of Count Rumford, an American-born British physicist and inventor. This book is divided in two parts. The first part gives a biographical sketch of Count Rumford, Benjamin Thompson, who was born on March 23, 1753 and died in 1814. This part also discusses the contemporary caloric theory and the reason why Rumford disbelieved the theory. The second part presents his technical works, discoveries, and contributions in the field of physics. Some of which are his demonstration of the e

  3. Quality control of radiation counting systems and measurement of minimum detectable activity

    International Nuclear Information System (INIS)

    Song, Byoung Chul; Han, Sung Sim; Kim, Young Bok; Jee, Kwang Yong; Sohn, Se Chul

    2004-01-01

    Various radiation counters have been using to determine radioactivity of radwastes for disposal. A radiation counting system was set up using a radiation detector chosen in this study and its stability was investigated through the periodic determination of background and counting efficiencies in accordance with a quality control program to increase the confidence level. The average background level for the γ-spectrometer was 1.59 cps and the average counting level for the standard sample was 45248 dps within 20 confidence levels. The average alpha background level for the low background α/β counting system was 0.31 cpm and the efficiency for alpha counting was 34.38 %. The average beta background level for the α/β counting system was 1.30 cpm and the efficiency for beta counting was 46.5%. The background level in the region of 3H and 14C for the liquid scintillation counting system was 2.52 and 3.31 cpm and the efficiency for alpha counting was 58.5 and 95.6%, respectively. The minimum detectable activity for the γ-spectrometer was found to be 3.2 Bq/mL and 3.8 Bq/mL for the liquid scintillation counter, and 20.5 and 23.0 Bq/mL, respectively for the α and β counting system

  4. Analysis of spatial count data using Kalman smoothing

    DEFF Research Database (Denmark)

    Dethlefsen, Claus

    2007-01-01

    We consider spatial count data from an agricultural field experiment. Counts of weed plants in a field have been recorded in a project on precision farming. Interest is in mapping the weed intensity so that the dose of herbicide applied at any location can be adjusted to the amount of weed present...

  5. Another Crisis Can We Count on the Reserves?

    Science.gov (United States)

    1994-05-16

    the " marshmallow " of volunteerism is something that is too soft of a concept to be counted upon. It only makes sense to develop a more well-defined...unrealistic. Involuntary activation has proven to be a hollow concept in practice, and planners are reluctant to count on the " marshmallow " of

  6. Material screening with HPGe counting station for PandaX experiment

    International Nuclear Information System (INIS)

    Wang, X.; Chen, X.; Fu, C.; Ji, X.; Liu, X.; Xie, P.; Zhang, T.; Mao, Y.; Wang, S.; Wang, H.

    2016-01-01

    A gamma counting station based on high-purity germanium (HPGe) detector was set up for the material screening of the PandaX dark matter experiments in the China Jinping Underground Laboratory. Low background gamma rate of 2.6 counts/min within the energy range of 20 to 2700 keV is achieved due to the well-designed passive shield. The sentivities of the HPGe detetector reach mBq/kg level for isotopes like K, U, Th, and even better for Co and Cs, resulted from the low-background rate and the high relative detection efficiency of 175%. The structure and performance of the counting station are described in this article. Detailed counting results for the radioactivity in materials used by the PandaX dark-matter experiment are presented. The upgrading plan of the counting station is also discussed.

  7. Theory of photoelectron counting statistics

    International Nuclear Information System (INIS)

    Blake, J.

    1980-01-01

    The purpose of the present essay is to provide a detailed analysis of those theoretical aspects of photoelectron counting which are capable of experimental verification. Most of our interest is in the physical phenomena themselves, while part is in the mathematical techniques. Many of the mathematical methods used in the analysis of the photoelectron counting problem are generally unfamiliar to physicists interested in the subject. For this reason we have developed the essay in such a fashion that, although primary interest is focused on the physical phenomena, we have also taken pains to carry out enough of the analysis so that the reader can follow the main details. We have chosen to present a consistently quantum mechanical version of the subject, in that we follow the Glauber theory throughout. (orig./WL)

  8. Liquid scintillation counting system with automatic gain correction

    International Nuclear Information System (INIS)

    Frank, R.B.

    1976-01-01

    An automatic liquid scintillation counting apparatus is described including a scintillating medium in the elevator ram of the sample changing apparatus. An appropriate source of radiation, which may be the external source for standardizing samples, produces reference scintillations in the scintillating medium which may be used for correction of the gain of the counting system

  9. Exponential Martingales and Changes of Measure for Counting Processes

    DEFF Research Database (Denmark)

    Sokol, Alexander; Hansen, Niels Richard

    2015-01-01

    We give sufficient criteria for the Doléans-Dade exponential of a stochastic integral with respect to a counting process local martingale to be a true martingale. The criteria are adapted particularly to the case of counting processes and are sufficiently weak to be useful and verifiable, as we i...... illustrate by several examples. In particular, the criteria allow for the construction of for example nonexplosive Hawkes processes, counting processes with stochastic intensities depending on diffusion processes as well as inhomogeneous finite-state Markov processes....

  10. Fast sequential Monte Carlo methods for counting and optimization

    CERN Document Server

    Rubinstein, Reuven Y; Vaisman, Radislav

    2013-01-01

    A comprehensive account of the theory and application of Monte Carlo methods Based on years of research in efficient Monte Carlo methods for estimation of rare-event probabilities, counting problems, and combinatorial optimization, Fast Sequential Monte Carlo Methods for Counting and Optimization is a complete illustration of fast sequential Monte Carlo techniques. The book provides an accessible overview of current work in the field of Monte Carlo methods, specifically sequential Monte Carlo techniques, for solving abstract counting and optimization problems. Written by authorities in the

  11. Application of neutron multiplicity counting to waste assay

    Energy Technology Data Exchange (ETDEWEB)

    Pickrell, M.M.; Ensslin, N. [Los Alamos National Lab., NM (United States); Sharpe, T.J. [North Carolina State Univ., Raleigh, NC (United States)

    1997-11-01

    This paper describes the use of a new figure of merit code that calculates both bias and precision for coincidence and multiplicity counting, and determines the optimum regions for each in waste assay applications. A {open_quotes}tunable multiplicity{close_quotes} approach is developed that uses a combination of coincidence and multiplicity counting to minimize the total assay error. An example is shown where multiplicity analysis is used to solve for mass, alpha, and multiplication and tunable multiplicity is shown to work well. The approach provides a method for selecting coincidence, multiplicity, or tunable multiplicity counting to give the best assay with the lowest total error over a broad spectrum of assay conditions. 9 refs., 6 figs.

  12. Counting statistics and loss corrections for the APS

    International Nuclear Information System (INIS)

    Lee, W.K.; Mills, D.M.

    1992-01-01

    It has been suggested that for timing experiments, it might be advantageous to arrange the bunches in the storage ring in an asymmetrical mode. In this paper, we determine the counting losses from pulsed x-ray sources from basic probabilistic arguments and from Poisson statistics. In particular the impact on single photon counting losses of a variety of possible filling modes for the Advanced Photon Source (APS) is examined. For bunches of equal current, a loss of 10% occurs whenever the count rate exceeds 21% of the bunch repetition rate. This changes slightly when bunches containing unequal numbers of particles are considered. The results are applied to several common detector/electronics systems

  13. Counting statistics and loss corrections for the APS

    International Nuclear Information System (INIS)

    Lee, W.K.; Mills, D.M.

    1992-01-01

    It has been suggested that for timing experiments, it might be advantageous to arrange the bunches in the storage ring in an asymmetrical mode. In this paper, we determine the counting losses from pulsed x-ray sources from basic probabilistic arguments and from Poisson statistics. In particular the impact on single-photon counting losses of a variety of possible filling modes for the Advanced Photon Source (APS) is examined. For bunches of equal current, a loss of 10% occurs whenever the count rate exceeds 21% of the bunch repetition rate. This changes slightly when bunches containing unequal numbers of particles are considered. The results are applied to several common detector/electronics systems

  14. Formación de un cordón litoral en Máncora-Perú, a raíz de El Niño de 1983

    Directory of Open Access Journals (Sweden)

    1993-01-01

    Full Text Available FORMATION D'UN CORDON LITTORAL A MANCORA, PEROU, APRÈS LE EL NIÑO DE 1983. On a prôné que les cordons littoraux fossiles de Colán, au nord du Pérou, pourraient s'être formés au cours d’événements très forts de phénomènes El Niño (Mega-Niño. Ce travail présente des informations sur la formation à Máncora, Pérou, d’un nouveau cordon suite à un événement extraordinaire El Niño en 1983, certainement le plus fort enregistré depuis la conquête espagnole. Cette formation est présentée comme une preuve de ce qui a été prôné pour Colán. Se ha postulado que los cordones litorales fósiles de Colán, en el norte del Perú, podrían haber sido formados durante eventos muy intensos del fenómeno El Niño (Mega-Niños. El presente trabajo documenta la formación en Máncora, Perú, de un nuevo cordón como consecuencia del evento extraordinario de El Niño de 1983, probablemente el más fuerte registrado en los últimos siglos desde la conquista española. Se presenta esta formación como evidencia de lo postulado para los cordones de Colán. ON THE FORMATION OF A NEW BEACH RIDGE IN MANCORA, PERU, AFTER EL NIÑO OF 1983. It has been postulated that the fossil discrete coastal ridges in Colán, Perú, were formed during extremely strong El Niño events of the past (Mega-Niños. This paper reports the formation of a new beach ridge in Máncora, Perú, after the extraordinary El Niño of 1983, probably the strongest El Niño registered in the last centuries, after the spanish conquest. The formation of this ridge is presented as evidence of what was postulated for the beach ridges of Colán.

  15. Accuracy and precision in activation analysis: counting

    International Nuclear Information System (INIS)

    Becker, D.A.

    1974-01-01

    Accuracy and precision in activation analysis was investigated with regard to counting of induced radioactivity. The various parameters discussed include configuration, positioning, density, homogeneity, intensity, radioisotopic purity, peak integration, and nuclear constants. Experimental results are presented for many of these parameters. The results obtained indicate that counting errors often contribute significantly to the inaccuracy and imprecision of analyses. The magnitude of these errors range from less than 1 percent to 10 percent or more in many cases

  16. Remote system for counting of nuclear pulses

    International Nuclear Information System (INIS)

    Nieves V, J.A.; Garcia H, J.M.; Aguilar B, M.A.

    1999-01-01

    In this work, it is describe technically the remote system for counting of nuclear pulses, an integral system of the project radiological monitoring in a petroleum distillation tower. The system acquires the counting of incident nuclear particles in a nuclear detector which process this information and send it in serial form, using the RS-485 toward a remote receiver, which can be a Personal computer or any other device capable to interpret the communication protocol. (Author)

  17. Eosinophil count is positively correlated with coronary artery calcification

    International Nuclear Information System (INIS)

    Tanaka, Muhei; Fukui, Michiaki; Yamasaki, Masahiro; Hasegawa, Goji; Oda, Yohei; Nakamura, Naoto; Tomiyasu, Ki-ichiro; Akabame, Satoshi; Nakano, Koji

    2012-01-01

    Recent studies suggested that allergic disorders and increased eosinophil count were associated with atherosclerosis. The purpose of this study was to assess the relationship between eosinophil count and coronary artery calcification (CAC). We performed a cross-sectional study in 1363 consecutive participants with clinical suspicion of coronary heart disease (CHD). We evaluated the relationships between CAC score determined by multislice CT and peripheral eosinophil count as well as major cardiovascular risk factors, including age, body mass index, smoking status, hypertension, dyslipidemia, diabetes mellitus (DM), high-sensitivity C-reactive protein and estimated glomerular filtration rate (eGFR). Sex (P=0.0004), hypertension (P=0.0002), dyslipidemia (P=0.0004) and DM (P=0.0061) were associated with log (CAC+1), respectively. Positive correlations were found between log (CAC+1), and age (r=0.325, P<0.0001) and eosinophil count (r=0.165, P<0.0001). Negative correlations were found between log (CAC+1) and eGFR (r=-0.166, P<0.0001). Multivariate linear regression analysis demonstrated that age (β=0.314, P<0.0001), sex (β=0.124, P<0.0001), hypertension (β=0.084, P=0.0008), DM (β=0.108, P<0.0001), eGFR (β=-0.079, P=0.0021) and eosinophil count (β=0.147, P<0.0001) were independent determinants of log (CAC+1). In conclusion, eosinophil count correlated positively with CAC in participants with clinical suspicion of CHD. (author)

  18. Make My Trip Count 2015

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — The Make My Trip Count (MMTC) commuter survey, conducted in September and October 2015 by GBA, the Pittsburgh 2030 District, and 10 other regional transportation...

  19. Platelet Counts, MPV and PDW in Culture Proven and Probable Neonatal Sepsis and Association of Platelet Counts with Mortality Rate

    International Nuclear Information System (INIS)

    Ahmad, M. S.; Waheed, A.

    2014-01-01

    Objective: To determine frequency of thrombocytopenia and thrombocytosis, the MPV (mean platelet volume) and PDW (platelet distribution width) in patients with probable and culture proven neonatal sepsis and determine any association between platelet counts and mortality rate. Study Design: Descriptive analytical study. Place and Duration of Study: NICU, Fazle Omar Hospital, from January 2011 to December 2012. Methodology: Cases of culture proven and probable neonatal sepsis, admitted in Fazle Omar Hospital, Rabwah, were included in the study. Platelet counts, MPV and PDW of the cases were recorded. Mortality was documented. Frequencies of thrombocytopenia ( 450000/mm3) were ascertained. Mortality rates in different groups according to platelet counts were calculated and compared by chi-square test to check association. Results: Four hundred and sixty nine patients were included; 68 (14.5%) of them died. One hundred and thirty six (29%) had culture proven sepsis, and 333 (71%) were categorized as probable sepsis. Thrombocytopenia was present in 116 (24.7%), and thrombocytosis was present in 36 (7.7%) cases. Median platelet count was 213.0/mm3. Twenty eight (27.7%) patients with thrombocytopenia, and 40 (12.1%) cases with normal or raised platelet counts died (p < 0.001). Median MPV was 9.30, and median PDW was 12.30. MPV and PDW of the patients who died and who were discharged were not significantly different from each other. Conclusion: Thrombocytopenia is a common complication of neonatal sepsis. Those with thrombocytopenia have higher mortality rate. No significant difference was present between PDW and MPV of the cases who survived and died. (author)

  20. Health Behavior Theory in Popular Calorie Counting Apps: A Content Analysis

    OpenAIRE

    Davis, Siena F; Ellsworth, Marisa A; Payne, Hannah E; Hall, Shelby M; West, Joshua H; Nordhagen, Amber L

    2016-01-01

    Background Although the Health & Fitness category of the Apple App Store features hundreds of calorie counting apps, the extent to which popular calorie counting apps include health behavior theory is unknown. Objective This study evaluates the presence of health behavior theory in calorie counting apps. Methods Data for this study came from an extensive content analysis of the 10 most popular calorie counting apps in the Health & Fitness category of the Apple App Store. Results Each app was ...

  1. Problems and precision of the alpha scintillation radon counting system

    International Nuclear Information System (INIS)

    Lucas, H.F.; Markuu, F.

    1985-01-01

    Variations in efficiency as large as 3% have been found for radon scintillation counting systems in which the photomultiplier tubes are sensitive to the thermoluminescent photons emitted by the scintillator after exposure to light or for which the resolution has deteriorated. The additional standard deviation caused by counting a radon chamber on multiple counting systems has been evaluated and the effect, if present, did not exceed about 0.1%. The chambers have been calibrated for the measurement of radon in air, and the standard deviation was equal to statistical counting error combined with a systematic error of 1.1%. 3 references, 2 figures, 2 tables

  2. Daily variability of strongyle fecal egg counts in horses

    DEFF Research Database (Denmark)

    Carstensen, Helena; Larsen, Lene; Ritz, Christian

    2013-01-01

    Strongyle parasites are ubiquitous in grazing horses and constitute a potential threat to equine health. Feces were collected from six horses four times daily over a period of 5 days. Fecal egg counts (FECs) were performed to identify any diurnal rhythms in strongyle egg shedding and to quantify...... variability at the different levels: individual horses, repeated counts, repeated subsamples, different time points, and different days. No significant differences in FECs were found between the different time points (P = .11). The variables-horse, day, subsample, and egg count-accounted for a variance of 104...... subsamples and repeated egg counts on the same subsamples, whereas the variability of FECs between following days can be considered negligible. The findings of this study have implication for designing and performing field surveillance of strongyle FEC levels and applying the FEC reduction test...

  3. Detection and counting systems

    International Nuclear Information System (INIS)

    Abreu, M.A.N. de

    1976-01-01

    Detection devices based on gaseous ionization are analysed, such as: electroscopes ionization chambers, proportional counters and Geiger-Mueller counters. Scintillation methods are also commented. A revision of the basic concepts in electronics is done and the main equipment for counting is detailed. In the study of gama spectrometry, scintillation and semiconductor detectors are analysed [pt

  4. Radiation intensity counting system

    International Nuclear Information System (INIS)

    Peterson, R.J.

    1982-01-01

    A method is described of excluding the natural dead time of the radiation detector (or eg Geiger-Mueller counter) in a ratemeter counting circuit, thus eliminating the need for dead time corrections. Using a pulse generator an artificial dead time is introduced which is longer than the natural dead time of the detector. (U.K.)

  5. Development of a stained cell nuclei counting system

    Science.gov (United States)

    Timilsina, Niranjan; Moffatt, Christopher; Okada, Kazunori

    2011-03-01

    This paper presents a novel cell counting system which exploits the Fast Radial Symmetry Transformation (FRST) algorithm [1]. The driving force behind our system is a research on neurogenesis in the intact nervous system of Manduca Sexta or the Tobacco Hornworm, which was being studied to assess the impact of age, food and environment on neurogenesis. The varying thickness of the intact nervous system in this species often yields images with inhomogeneous background and inconsistencies such as varying illumination, variable contrast, and irregular cell size. For automated counting, such inhomogeneity and inconsistencies must be addressed, which no existing work has done successfully. Thus, our goal is to devise a new cell counting algorithm for the images with non-uniform background. Our solution adapts FRST: a computer vision algorithm which is designed to detect points of interest on circular regions such as human eyes. This algorithm enhances the occurrences of the stained-cell nuclei in 2D digital images and negates the problems caused by their inhomogeneity. Besides FRST, our algorithm employs standard image processing methods, such as mathematical morphology and connected component analysis. We have evaluated the developed cell counting system with fourteen digital images of Tobacco Hornworm's nervous system collected for this study with ground-truth cell counts by biology experts. Experimental results show that our system has a minimum error of 1.41% and mean error of 16.68% which is at least forty-four percent better than the algorithm without FRST.

  6. Quality control methods in accelerometer data processing: identifying extreme counts.

    Directory of Open Access Journals (Sweden)

    Carly Rich

    Full Text Available Accelerometers are designed to measure plausible human activity, however extremely high count values (EHCV have been recorded in large-scale studies. Using population data, we develop methodological principles for establishing an EHCV threshold, propose a threshold to define EHCV in the ActiGraph GT1M, determine occurrences of EHCV in a large-scale study, identify device-specific error values, and investigate the influence of varying EHCV thresholds on daily vigorous PA (VPA.We estimated quantiles to analyse the distribution of all accelerometer positive count values obtained from 9005 seven-year old children participating in the UK Millennium Cohort Study. A threshold to identify EHCV was derived by differentiating the quantile function. Data were screened for device-specific error count values and EHCV, and a sensitivity analysis conducted to compare daily VPA estimates using three approaches to accounting for EHCV.Using our proposed threshold of ≥ 11,715 counts/minute to identify EHCV, we found that only 0.7% of all non-zero counts measured in MCS children were EHCV; in 99.7% of these children, EHCV comprised < 1% of total non-zero counts. Only 11 MCS children (0.12% of sample returned accelerometers that contained negative counts; out of 237 such values, 211 counts were equal to -32,768 in one child. The medians of daily minutes spent in VPA obtained without excluding EHCV, and when using a higher threshold (≥19,442 counts/minute were, respectively, 6.2% and 4.6% higher than when using our threshold (6.5 minutes; p<0.0001.Quality control processes should be undertaken during accelerometer fieldwork and prior to analysing data to identify monitors recording error values and EHCV. The proposed threshold will improve the validity of VPA estimates in children's studies using the ActiGraph GT1M by ensuring only plausible data are analysed. These methods can be applied to define appropriate EHCV thresholds for different accelerometer models.

  7. Application of PSD for low level alpha counting using liquid scintillation counting

    International Nuclear Information System (INIS)

    Krishnamachari, G.; Vaze, P.K.; Iyer, M.R.

    1989-01-01

    In the liquid scintillator the light produced by alpha particles decays differently than those produced by electrons. Pulse shape discrimination (PSD) methods are employed to estimate low levels of alpha emitting radionuclides by reducing the background due to either beta or gamma events. An attempt is being made to develop a liquid scintillation counting sytem using a simple PSD circuit to achieve a background of 0.01 counts/min. The PSD circuit is based on measuring zero cross over points to differentiate particle types. The input signal is first differentiated by a delay line and subsequently by a RC circuit. The width of the initial part of the doubly differentiated pulse is different for alpha and beta pulses. This width is converted to amplitude by a time-to-amplitude converter (TAC). The higher amplitude pulses from the TAC are due to alpha particles and they are separated by an integral discriminator. The output from the integral discriminator opens a linear gate to record the pulse height spectrum. The figure of merit of the PSD circuit and background in the alpha energy channel have been worked out using different scintillator types. (author). 4 figs

  8. Temporal aggregation of migration counts can improve accuracy and precision of trends

    Directory of Open Access Journals (Sweden)

    Tara L. Crewe

    2016-12-01

    Full Text Available Temporal replicate counts are often aggregated to improve model fit by reducing zero-inflation and count variability, and in the case of migration counts collected hourly throughout a migration, allows one to ignore nonindependence. However, aggregation can represent a loss of potentially useful information on the hourly or seasonal distribution of counts, which might impact our ability to estimate reliable trends. We simulated 20-year hourly raptor migration count datasets with known rate of change to test the effect of aggregating hourly counts to daily or annual totals on our ability to recover known trend. We simulated data for three types of species, to test whether results varied with species abundance or migration strategy: a commonly detected species, e.g., Northern Harrier, Circus cyaneus; a rarely detected species, e.g., Peregrine Falcon, Falco peregrinus; and a species typically counted in large aggregations with overdispersed counts, e.g., Broad-winged Hawk, Buteo platypterus. We compared accuracy and precision of estimated trends across species and count types (hourly/daily/annual using hierarchical models that assumed a Poisson, negative binomial (NB or zero-inflated negative binomial (ZINB count distribution. We found little benefit of modeling zero-inflation or of modeling the hourly distribution of migration counts. For the rare species, trends analyzed using daily totals and an NB or ZINB data distribution resulted in a higher probability of detecting an accurate and precise trend. In contrast, trends of the common and overdispersed species benefited from aggregation to annual totals, and for the overdispersed species in particular, trends estimating using annual totals were more precise, and resulted in lower probabilities of estimating a trend (1 in the wrong direction, or (2 with credible intervals that excluded the true trend, as compared with hourly and daily counts.

  9. Is total lymphocyte count related to nutritional markers in hospitalized older adults?

    Directory of Open Access Journals (Sweden)

    Vânia Aparecida LEANDRO-MERHI

    Full Text Available ABSTRACT BACKGROUND Older patients are commonly malnourished during hospital stay, and a high prevalence of malnutrition is found in hospitalized patients aged more than 65 years. OBJECTIVE To investigate whether total lymphocyte count is related to other nutritional markers in hospitalized older adults. METHODS Hospitalized older adults (N=131 were recruited for a cross-sectional study. Their nutritional status was assessed by the Nutritional Risk Screening (NRS, anthropometry, and total lymphocyte count. The statistical analyses included the chi-square test, Fisher's exact test, and Mann-Whitney test. Spearman's linear correlation coefficient determined whether total lymphocyte count was correlated with the nutritional markers. Multiple linear regression determined the parameters associated with lymphocyte count. The significance level was set at 5%. RESULTS According to the NRS, 41.2% of the patients were at nutritional risk, and 36% had mild or moderate depletion according to total lymphocyte count. Total lymphocyte count was weakly correlated with mid-upper arm circumference (r=0.20507; triceps skinfold thickness (r=0.29036, and length of hospital stay (r= -0.21518. Total lymphocyte count in different NRS categories differed significantly: older adults who were not at nutritional risk had higher mean and median total lymphocyte count ( P =0.0245. Multiple regression analysis showed that higher lymphocyte counts were associated with higher triceps skinfold thicknesses and no nutritional risk according to the NRS. CONCLUSION Total lymphocyte count was correlated with mid-upper arm circumference, triceps skinfold thickness, and nutritional risk according to the NRS. In multiple regression the combined factors that remained associated with lymphocyte count were NRS and triceps skinfold thickness. Therefore, total lymphocyte count may be considered a nutritional marker. Other studies should confirm these findings.

  10. Effect of strategic deworming of village cattle in Uganda with moxidectin pour-on on faecal egg count and pasture larval counts : short communication

    Directory of Open Access Journals (Sweden)

    J.W. Magona

    2004-06-01

    Full Text Available Strategic application of moxidectin pour-on (Cydectin(R was evaluated in Uganda for its effect on pasture larval counts and gastrointestinal nematode faecal egg counts in village cattle kept under tethering (semi-intensive grazing management. The strategic deworming schedule involved treating cattle twice at an interval of 2 months, at the end of the 1st wet season and during the 2nd wet season. Two groups of 30 cattle, each consisting of a treated and a control group, were examined for nematode infections every 4 weeks from June 1999 to January 2000. The treated group had significantly lower mean faecal egg counts than the untreated groups (t-value = 2.47, P < 0.05. Generally, the pasture larval counts on treated farms were lower than on untreated ones, but not significantly so (t-value = 2.22, P = 0.068. Pasture larval counts with different nematode species on treated farms were lower than on untreated ones, but the differences were not significant for Haemonchus spp. (t-value=1.68, P=0.145, Oesophagostomum spp. (t-value= 1.87, P=0.111, Trichostrongylus spp. (t-value=1.93, P=0.102, Dictyocaulus spp. (t-value= -0.74, P=0.485 and Cooperia spp. (t-value=-1.00, P=0.356. Treated farms did , however, have significantly lower pasture larval counts of Bunostomum spp. (t-value=4.64, P<0.05. This study has revealed that the application ofmoxidectin pour-on on cattle has an effect on faecal egg count and pasture contamination under the tethering grazing system. Moxidectin pour-on and the strategic deworming schedule evaluated here could be used for the control of gastrointestinal nematode infections in cattle by small-scale farmers who practise tethering or semi-intensive grazing management in Uganda and other tropical countries, especially where there is a bimodal rainfall pattern.

  11. Agreement of manual cell counts and automated counts of the scil Vet abc Plus(+) hematology analyzer for analysis of equine synovial fluid.

    Science.gov (United States)

    Van de Water, Eline; Oosterlinck, Maarten; Duchateau, Luc; Pille, Frederik

    2016-06-01

    The purpose of this study was to determine whether the scil Vet abc Plus(+) (SCIL Animal Care Company, Altorf, France), an impedance hematology analyzer, can accurately quantify and differentiate nucleated blood cells (NBCs) in equine synovial fluid. Synovial fluid samples (n=242) in different stages of experimentally induced inflammation were analyzed with and without hyaluronidase pretreatment and compared to manual hemocytometer counts and smear reviews. No significant effect of hyaluronidase pretreatment was observed. Total nucleated cell counts of the scil Vet abc Plus(+) were significantly higher compared to the manual method (P=0.02), yet the difference was small and clinically irrelevant (ratio manual/automated count equal to 0.97 with 95% CI [0.95, 1.00]). Differential cell counts of the scil Vet abc Plus(+) were not accurate. In conclusion, the scil Vet abc Plus(+) hematology analyzer is highly accurate for quantification, but not accurate for differentiation of NBCs in equine synovial fluid. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. How to count an introduction to combinatorics

    CERN Document Server

    Allenby, RBJT

    2010-01-01

    What's It All About? What Is Combinatorics? Classic Problems What You Need to Know Are You Sitting Comfortably? Permutations and Combinations The Combinatorial Approach Permutations CombinationsApplications to Probability Problems The Multinomial Theorem Permutations and Cycles Occupancy Problems Counting the Solutions of Equations New Problems from Old A ""Reduction"" Theorem for the Stirling Numbers The Inclusion-Exclusion Principle Double Counting Derangements A Formula for the Stirling NumbersStirling and Catalan Numbers Stirling Numbers Permutations and Stirling Numbers Catalan Numbers Pa

  13. Internal dosimetry by whole body counting techniques

    International Nuclear Information System (INIS)

    Sharma, R.C.

    1995-01-01

    Over decades, whole body counting and bioassay - the two principal methods of internal dosimetry have been most widely used to assess, limit and control the intakes of radioactive materials and the consequent internal doses by the workers in nuclear industry. This paper deals with the whole body counting techniques. The problems inherent in the interpretation of monitoring data and likely future directions of development in the assessments of internal doses by direct methods are outlined. (author). 14 refs., 9 figs., 1 tab

  14. Optimizing the duration of point counts for monitoring trends in bird populations

    Science.gov (United States)

    Jared Verner

    1988-01-01

    Minute-by-minute analysis of point counts of birds in mixed-conifer forests in the Sierra National Forest, central California, showed that cumulative counts of species and individuals increased in a curvilinear fashion but did not reach asymptotes after 10 minutes of counting. Comparison of the expected number of individuals counted per hour with various combinations...

  15. Passive hand movements disrupt adults’ counting strategies

    Directory of Open Access Journals (Sweden)

    Ineke eImbo

    2011-09-01

    Full Text Available In the present study, we experimentally tested the role of hand motor circuits in simple-arithmetic strategies. Educated adults solved simple additions (e.g., 8+3 or simple subtractions (e.g., 11–3 while they were required to retrieve the answer from long-term memory (e.g., knowing that 8+3 = 11, to transform the problem by making an intermediate step (e.g., 8+3 = 8+2+1 = 10+1 = 11 or to count one-by-one (e.g., 8+3 = 8…9…10…11. During the process of solving the arithmetic problems, the experimenter did or did not move the participants’ hand on a 4-point matrix. The results show that passive hand movements disrupted the counting strategy while leaving the other strategies unaffected. This pattern of results is in agreement with a procedural account, showing that the involvement of hand motor circuits in adults’ mathematical abilities is reminiscent of finger counting during childhood.

  16. Optimizing the calculation of point source count-centroid in pixel size measurement

    International Nuclear Information System (INIS)

    Zhou Luyi; Kuang Anren; Su Xianyu

    2004-01-01

    Purpose: Pixel size is an important parameter of gamma camera and SPECT. A number of Methods are used for its accurate measurement. In the original count-centroid method, where the image of a point source(PS) is acquired and its count-centroid calculated to represent PS position in the image, background counts are inevitable. Thus the measured count-centroid (Xm) is an approximation of the true count-centroid (Xp) of the PS, i.e. Xm=Xp+(Xb-Xp)/(1+Rp/Rb), where Rp is the net counting rate of the PS, Xb the background count-centroid and Rb the background counting rate. To get accurate measurement, Rp must be very big, which is unpractical, resulting in the variation of measured pixel size. Rp-independent calculation of PS count-centroid is desired. Methods: The proposed method attempted to eliminate the effect of the term (Xb-Xp)/(1+Rp/Rb) by bringing Xb closer to Xp and by reducing Rb. In the acquired PS image, a circular ROI was generated to enclose the PS, the pixel with the maximum count being the center of the ROI. To choose the diameter (D) of the ROI, a Gaussian count distribution was assumed for the PS, accordingly, K=I-(0.5)D/R percent of the total PS counts was in the ROI, R being the full width at half maximum of the PS count distribution. D was set to be 6*R to enclose most (K=98.4%) of the PS counts. The count-centroid of the ROI was calculated to represent Xp. The proposed method was tested in measuring the pixel size of a well-tuned SPECT, whose pixel size was estimated to be 3.02 mm according to its mechanical and electronic setting (128*128 matrix, 387 mm UFOV, ZOOM=1). For comparison, the original method, which was use in the former versions of some commercial SPECT software, was also tested. 12 PSs were prepared and their image acquired and stored. The net counting rate of the PSs increased from 10cps to 1183cps. Results: Using the proposed method, the measured pixel size (in mm) varied only between 3.00 and 3.01( mean= 3.01±0.00) as Rp increased

  17. Count Nouns - Mass Nouns, Neat Nouns - Mess Nouns

    Directory of Open Access Journals (Sweden)

    Fred Landman

    2010-12-01

    Full Text Available In this paper I propose and formalize a theory of the mass-count distinction in which the denotations of count nouns are built from non-overlapping generators, while the denotations of mass nouns are built from overlapping generators. Counting is counting of generators, and it will follow that counting is only correct on count denotations. I will show that the theory allows two kinds of mass nouns: mess mass nouns with denotations built from overlapping minimal generators, and neat mass nouns with denotations built from overlapping generators, where the overlap is not located in the minimal generators. Prototypical mass nouns like meat and mud are of the first kind. I will argue that mass nouns like furniture and kitchenware are of the second type. I will discuss several phenomena—all involving one way or the other explicitly or implicitly individual classifiers like stuks in Dutch—that show that both distinctions mass/count and mess/neat are linguistically robust. I will show in particular that nouns like kitchenware pattern in various ways like count nouns, and not like mess mass nouns, and that these ways naturally involve the neat structure of their denotation. I will also show that they are real mass nouns: they can involve measures in the way mess mass nouns can and count nouns cannot. I will discuss grinding interpretations of count nouns, here rebaptized fission interpretations, and argue that these interpretations differ in crucial ways from the interpretations of lexical mass nouns. The paper will end with a foundational problem raised by fission interpretations, and in the course of this, atomless interpretation domains will re-enter the scene through the back door.ReferencesBarner, D. & Snedeker, J. 2005. ‘Quantity judgements and individuation: evidence that mass nouns count’. Cognition 97: 41–66.http://dx.doi.org/10.1016/j.cognition.2004.06.009PMid:16139586Bunt, H. 1985. Mass Terms and Model Theoretic Semantics. Cambridge

  18. Soil Characteristics, Microbial Compostion of Plot, Leaf Count and ...

    African Journals Online (AJOL)

    Soil Characteristics, Microbial Compostion of Plot, Leaf Count and Sprout Studies of Cocoyam ( Colocasia [Schott] and Xanthosoma [Schott], Araceae) Collected in Edo State, ... Science, Technology and Arts Research Journal ... Government Areas (LGA) in Edo state and describe them based on leaf count and sprout

  19. Step-count guidelines referenced on 60-minutes of moderate/vigorous physical activity

    Directory of Open Access Journals (Sweden)

    Fabio Eduardo Fontana

    2015-03-01

    Full Text Available The purpose of this study was to establish step-count guidelines for sixth-grade students and assess the ability of step-counts to discriminate between students achieving and not achieving 60-minutes of moderate to vigorous physical activity daily. 201 sixth-grade students completed the study. They wore a pedometer and an accelerometer at the waist level for one full day. ROC curves were used to establish step-count guidelines and determine the diagnostic accuracy of step-counts. Sixth grade students need 12,118 steps/day to reach adequate daily levels of physical activity. The AUC indicated good diagnostic accuracy of step-counts. Suggested step-count guidelines can be a useful tool for identifying children who need to increase their daily levels of physical activity. The step-count cutoff proposed in this study is adequate for discriminating between sixth grade students reaching and not reaching recommended levels of physical activity.

  20. Bayesian approach in MN low dose of radiation counting

    International Nuclear Information System (INIS)

    Serna Berna, A.; Alcaraz, M.; Acevedo, C.; Navarro, J. L.; Alcanzar, M. D.; Canteras, M.

    2006-01-01

    The Micronucleus assay in lymphocytes is a well established technique for the assessment of genetic damage induced by ionizing radiation. Due to the presence of a natural background of MN the net MN is obtained by subtracting this value to the gross value. When very low doses of radiation are given the induced MN is close even lower than the predetermined background value. Furthermore, the damage distribution induced by the radiation follows a Poisson probability distribution. These two facts pose a difficult task to obtain the net counting rate in the exposed situations. It is possible to overcome this problem using a bayesian approach, in which the selection of a priori distributions for the background and net counting rate plays an important role. In the present work we make a detailed analysed using bayesian theory to infer the net counting rate in two different situations: a) when the background is known for an individual sample, using exact value value for the background and Jeffreys prior for the net counting rate, and b) when the background is not known and we make use of a population background distribution as background prior function and constant prior for the net counting rate. (Author)

  1. Drone-based Object Counting by Spatially Regularized Regional Proposal Network

    OpenAIRE

    Hsieh, Meng-Ru; Lin, Yen-Liang; Hsu, Winston H.

    2017-01-01

    Existing counting methods often adopt regression-based approaches and cannot precisely localize the target objects, which hinders the further analysis (e.g., high-level understanding and fine-grained classification). In addition, most of prior work mainly focus on counting objects in static environments with fixed cameras. Motivated by the advent of unmanned flying vehicles (i.e., drones), we are interested in detecting and counting objects in such dynamic environments. We propose Layout Prop...

  2. Relationship between salivary flow rates and Candida counts in subjects with xerostomia.

    Science.gov (United States)

    Torres, Sandra R; Peixoto, Camila Bernardo; Caldas, Daniele Manhães; Silva, Eline Barboza; Akiti, Tiyomi; Nucci, Márcio; de Uzeda, Milton

    2002-02-01

    This study evaluated the relationship between salivary flow and Candida colony counts in the saliva of patients with xerostomia. Sialometry and Candida colony-forming unit (CFU) counts were taken from 112 subjects who reported xerostomia in a questionnaire. Chewing-stimulated whole saliva was collected and streaked in Candida plates and counted in 72 hours. Species identification was accomplished under standard methods. There was a significant inverse relationship between salivary flow and Candida CFU counts (P =.007) when subjects with high colony counts were analyzed (cutoff point of 400 or greater CFU/mL). In addition, the median sialometry of men was significantly greater than that of women (P =.003), even after controlling for confounding variables like underlying disease and medications. Sjögren's syndrome was associated with low salivary flow rate (P =.007). There was no relationship between the median Candida CFU counts and gender or age. There was a high frequency (28%) of mixed colonization. Candida albicans was the most frequent species, followed by C parapsilosis, C tropicalis, and C krusei. In subjects with high Candida CFU counts there was an inverse relationship between salivary flow and Candida CFU counts.

  3. Operation voltage of the counting system of nuclear traces in solids

    International Nuclear Information System (INIS)

    Garcia, M.L.; Quirino, L.L.; Mireles, F.; Davila, J.I.; Pinedo, J.L.; Lugo, J.F.; Vadillo, V.E.

    2002-01-01

    The semi-automatic counting system based on electric spark and used for traces reading in solid state detectors is evaluated for obtaining its counting voltage and also the breaking voltage of material. In the treatment of the solid state detectors it is continued the NTD methodology for concluding with the individual counting of the films, whose graphics offer the existing relationship among the applied voltage and the traces number. From each film a counting and breaking voltages are obtained. Finally, an average voltage of all them is estimated. (Author)

  4. Study of mast cell count in skin tags

    Directory of Open Access Journals (Sweden)

    Zaher Hesham

    2007-01-01

    Full Text Available Background: Skin tags or acrochordons are common tumors of middle-aged and elderly subjects. They consist of loose fibrous tissue and occur mainly on the neck and major flexures as small, soft, pedunculated protrusions. Objectives: The aim was to compare the mast cells count in skin tags to adjacent normal skin in diabetic and nondiabetic participants in an attempt to elucidate the possible role of mast cells in the pathogenesis of skin tags. Participants and Methods: Thirty participants with skin tags were divided into group I (15 nondiabetic participants and group II (15 diabetic participants. Three biopsies were obtained from each participant: a large skin tag, a small skin tag and adjacent normal skin. Mast cell count from all the obtained sections was carried out, and the mast cell density was expressed as the average mast cell count/high power field (HPF. Results: A statistically significant increase in mast cells count in skin tags in comparison to normal skin was detected in group I and group II. There was no statistically significant difference between mast cell counts in skin tags of both the groups. Conclusion: Both the mast cell mediators and hyperinsulinemia are capable of inducing fibroblast proliferation and epidermal hyperplasia that are the main pathologic abnormalities seen in all types of skin tags. However, the presence of mast cells in all examined skin tags regardless of diabetes and obesity may point to the possible crucial role of mast cells in the etiogenesis of skin tags through its interaction with fibroblasts and keratinocytes.

  5. Counting in Lattices: Combinatorial Problems from Statistical Mechanics.

    Science.gov (United States)

    Randall, Dana Jill

    In this thesis we consider two classical combinatorial problems arising in statistical mechanics: counting matchings and self-avoiding walks in lattice graphs. The first problem arises in the study of the thermodynamical properties of monomers and dimers (diatomic molecules) in crystals. Fisher, Kasteleyn and Temperley discovered an elegant technique to exactly count the number of perfect matchings in two dimensional lattices, but it is not applicable for matchings of arbitrary size, or in higher dimensional lattices. We present the first efficient approximation algorithm for computing the number of matchings of any size in any periodic lattice in arbitrary dimension. The algorithm is based on Monte Carlo simulation of a suitable Markov chain and has rigorously derived performance guarantees that do not rely on any assumptions. In addition, we show that these results generalize to counting matchings in any graph which is the Cayley graph of a finite group. The second problem is counting self-avoiding walks in lattices. This problem arises in the study of the thermodynamics of long polymer chains in dilute solution. While there are a number of Monte Carlo algorithms used to count self -avoiding walks in practice, these are heuristic and their correctness relies on unproven conjectures. In contrast, we present an efficient algorithm which relies on a single, widely-believed conjecture that is simpler than preceding assumptions and, more importantly, is one which the algorithm itself can test. Thus our algorithm is reliable, in the sense that it either outputs answers that are guaranteed, with high probability, to be correct, or finds a counterexample to the conjecture. In either case we know we can trust our results and the algorithm is guaranteed to run in polynomial time. This is the first algorithm for counting self-avoiding walks in which the error bounds are rigorously controlled. This work was supported in part by an AT&T graduate fellowship, a University of

  6. An automated cell-counting algorithm for fluorescently-stained cells in migration assays

    Directory of Open Access Journals (Sweden)

    Novielli Nicole M

    2011-10-01

    Full Text Available Abstract A cell-counting algorithm, developed in Matlab®, was created to efficiently count migrated fluorescently-stained cells on membranes from migration assays. At each concentration of cells used (10,000, and 100,000 cells, images were acquired at 2.5 ×, 5 ×, and 10 × objective magnifications. Automated cell counts strongly correlated to manual counts (r2 = 0.99, P

  7. How fast can quantum annealers count?

    International Nuclear Information System (INIS)

    Hen, Itay

    2014-01-01

    We outline an algorithm for the quantum counting problem using adiabatic quantum computation (AQC). We show that the mechanism of quantum-adiabatic evolution may be utilized toward estimating the number of solutions to a problem, and not only to find them. Using local adiabatic evolution, a process in which the adiabatic procedure is performed at a variable rate, the problem of counting the number of marked items in an unstructured database is solved quadratically faster than the corresponding classical algorithm. The above algorithm provides further evidence for the potentially powerful capabilities of AQC as a paradigm for more efficient problem solving on a quantum computer, and may be used as the basis for solving more sophisticated problems. (paper)

  8. Phase space quark counting rule

    International Nuclear Information System (INIS)

    Wei-gin, C.; Lo, S.

    1980-01-01

    A simple quark counting rule based on phase space consideration suggested before is used to fit all 39 recent experimental data points on inclusive reactions. Parameter free relations are found to agree with experiments. Excellent detail fits are obtained for 11 inclusive reactions

  9. Optimizing the calculation of point source count-centroid in pixel size measurement

    International Nuclear Information System (INIS)

    Zhou Luyi; Kuang Anren; Su Xianyu

    2004-01-01

    Pixel size is an important parameter of gamma camera and SPECT. A number of methods are used for its accurate measurement. In the original count-centroid method, where the image of a point source (PS) is acquired and its count-centroid calculated to represent PS position in the image, background counts are inevitable. Thus the measured count-centroid (X m ) is an approximation of the true count-centroid (X p ) of the PS, i.e. X m =X p + (X b -X p )/(1+R p /R b ), where Rp is the net counting rate of the PS, X b the background count-centroid and Rb the background counting. To get accurate measurement, R p must be very big, which is unpractical, resulting in the variation of measured pixel size. R p -independent calculation of PS count-centroid is desired. Methods: The proposed method attempted to eliminate the effect of the term (X b -X p )/(1 + R p /R b ) by bringing X b closer to X p and by reducing R b . In the acquired PS image, a circular ROI was generated to enclose the PS, the pixel with the maximum count being the center of the ROI. To choose the diameter (D) of the ROI, a Gaussian count distribution was assumed for the PS, accordingly, K=1-(0.5) D/R percent of the total PS counts was in the ROI, R being the full width at half maximum of the PS count distribution. D was set to be 6*R to enclose most (K=98.4%) of the PS counts. The count-centroid of the ROI was calculated to represent X p . The proposed method was tested in measuring the pixel size of a well-tuned SPECT, whose pixel size was estimated to be 3.02 mm according to its mechanical and electronic setting (128 x 128 matrix, 387 mm UFOV, ZOOM=1). For comparison, the original method, which was use in the former versions of some commercial SPECT software, was also tested. 12 PSs were prepared and their image acquired and stored. The net counting rate of the PSs increased from 10 cps to 1183 cps. Results: Using the proposed method, the measured pixel size (in mm) varied only between 3.00 and 3.01 (mean

  10. Automatic quench compensation for liquid scintillation counting system

    International Nuclear Information System (INIS)

    Nather, R.E.

    1978-01-01

    A method of automatic quench compensation is provided, where a reference measure of quench is taken on a sample prior to taking a sample count. The measure of quench is then compared with a reference voltage source which has been established to vary in proportion to the variation of the measure of quench with the level of a system parameter required to restore at least one isotope spectral energy endpoint substantially to a selected counting window discriminator level in order to determine the amount of adjustment of the system parameter required to restore the endpoint. This is followed by the appropriate adjustment of the system parameter required to restore the relative position of the discriminator windows and the sample spectrum and is followed in turn by taking a sample count

  11. A high dynamic range pulse counting detection system for mass spectrometry.

    Science.gov (United States)

    Collings, Bruce A; Dima, Martian D; Ivosev, Gordana; Zhong, Feng

    2014-01-30

    A high dynamic range pulse counting system has been developed that demonstrates an ability to operate at up to 2e8 counts per second (cps) on a triple quadrupole mass spectrometer. Previous pulse counting detection systems have typically been limited to about 1e7 cps at the upper end of the systems dynamic range. Modifications to the detection electronics and dead time correction algorithm are described in this paper. A high gain transimpedance amplifier is employed that allows a multi-channel electron multiplier to be operated at a significantly lower bias potential than in previous pulse counting systems. The system utilises a high-energy conversion dynode, a multi-channel electron multiplier, a high gain transimpedance amplifier, non-paralysing detection electronics and a modified dead time correction algorithm. Modification of the dead time correction algorithm is necessary due to a characteristic of the pulse counting electronics. A pulse counting detection system with the capability to count at ion arrival rates of up to 2e8 cps is described. This is shown to provide a linear dynamic range of nearly five orders of magnitude for a sample of aprazolam with concentrations ranging from 0.0006970 ng/mL to 3333 ng/mL while monitoring the m/z 309.1 → m/z 205.2 transition. This represents an upward extension of the detector's linear dynamic range of about two orders of magnitude. A new high dynamic range pulse counting system has been developed demonstrating the ability to operate at up to 2e8 cps on a triple quadrupole mass spectrometer. This provides an upward extension of the detector's linear dynamic range by about two orders of magnitude over previous pulse counting systems. Copyright © 2013 John Wiley & Sons, Ltd.

  12. Recent trends in counts of migrant hawks from northeastern North America

    Science.gov (United States)

    Titus, K.; Fuller, M.R.

    1990-01-01

    Using simple regression, pooled-sites route-regression, and nonparametric rank-trend analyses, we evaluated trends in counts of hawks migrating past 6 eastern hawk lookouts from 1972 to 1987. The indexing variable was the total count for a season. Bald eagle (Haliaeetus leucocephalus), peregrine falcon (Falco peregrinus), merlin (F. columbarius), osprey (Pandion haliaetus), and Cooper's hawk (Accipiter cooperii) counts increased using route-regression and nonparametric methods (P 0.10). We found no consistent trends (P > 0.10) in counts of sharp-shinned hawks (A. striatus), northern goshawks (A. gentilis) red-shouldered hawks (Buteo lineatus), red-tailed hawks (B. jamaicensis), rough-legged hawsk (B. lagopus), and American kestrels (F. sparverius). Broad-winged hawk (B. platypterus) counts declined (P < 0.05) based on the route-regression method. Empirical comparisons of our results with those for well-studied species such as the peregrine falcon, bald eagle, and osprey indicated agreement with nesting surveys. We suggest that counts of migrant hawks are a useful and economical method for detecting long-term trends in species across regions, particularly for species that otherwise cannot be easily surveyed.

  13. Comprehensive nuclear counting and detector characterisation system for the radiochemistry laboratory

    International Nuclear Information System (INIS)

    Parthasarathy, R.; Saisubalakshmi, D.; Mishra, G.K.; Srinivas, K.C.; Venkatasubramani, C.R.

    2004-01-01

    The paper describes a comprehensive nuclear pulse counting system that can cater to up to seven nuclear detector set-ups located in different places in the laboratory. Each detector set up has an interfacing module that conditions the amplifier pulses and transmits them to a common counting system. The microcontroller-based system receives these pulses through a multiplexer and counts the pulses for a user specified preset time. The system has a routine to determine detector plateau characteristics and fix the detector operating voltage. In this mode, the system collects the EHT-versus- counts data in a EHT programmed sequence and plots the profile. The system conducts the counting routine for a stipulated number of times and does all necessary statistical tests to ensure the proper functioning of the detector under test. The system also includes a test routine that checks the performance of the counting system by connecting it to a local pulse generator. The microcontroller based system interacts with a PC through RS232 communication for user interaction and reporting. (author)

  14. An automated approach for annual layer counting in ice cores

    Directory of Open Access Journals (Sweden)

    M. Winstrup

    2012-11-01

    Full Text Available A novel method for automated annual layer counting in seasonally-resolved paleoclimate records has been developed. It relies on algorithms from the statistical framework of hidden Markov models (HMMs, which originally was developed for use in machine speech recognition. The strength of the layer detection algorithm lies in the way it is able to imitate the manual procedures for annual layer counting, while being based on statistical criteria for annual layer identification. The most likely positions of multiple layer boundaries in a section of ice core data are determined simultaneously, and a probabilistic uncertainty estimate of the resulting layer count is provided, ensuring an objective treatment of ambiguous layers in the data. Furthermore, multiple data series can be incorporated and used simultaneously. In this study, the automated layer counting algorithm has been applied to two ice core records from Greenland: one displaying a distinct annual signal and one which is more challenging. The algorithm shows high skill in reproducing the results from manual layer counts, and the resulting timescale compares well to absolute-dated volcanic marker horizons where these exist.

  15. Poissonian and binomial models in radionuclide metrology by liquid scintillation counting

    International Nuclear Information System (INIS)

    Grau Malonda, A.

    1990-01-01

    Binomial and Poissonian models developed for calculating the counting efficiency from a free parameter is analysed in this paper. This model have been applied to liquid scintillator counting systems with two or three photomultipliers. It is mathematically demostrated that both models are equivalent and that the counting efficiencies calculated either from one or the other model are identical. (Author)

  16. Phase-space quark counting rule

    Energy Technology Data Exchange (ETDEWEB)

    Wei-Gin, Chao; Lo, Shui-Yin [Academia Sinica, Beijing (China). Inst. of High Energy Physics

    1981-05-21

    A simple quark counting rule based on the phase-space consideration suggested before is used to fit all 39 recent experimental data points on inclusive reactions. Parameter-free relations are found to agree with experiments. Excellent detail fits are obtained for 11 inclusive reactions.

  17. Advanced digital counting rate meter for gamma ray logging

    International Nuclear Information System (INIS)

    Kannan, S.; Meenakshi Sundari, A.; Rai, A.K.

    2013-01-01

    A compact, hand held controller based Advanced Digital Count Rate Meter (ADCRM) as a replacement of bulky Count Rate (analog) Meters (SBL-2A) was designed, developed and fabricated to carry out Gamma-Ray borehole logging with Geiger Muller (GM) tubes and Scintillation (SC) detectors. In the hardware the functionality of analog meter simulation, digital counting of gamma events and auto reference adjustment to use different length of armour cable winches were implemented. The in-built software evaluates grade in ppm and at the end of logging, the reports are prepared automatically. ADCRM was developed in-house to assist the uranium mineral exploration in AMD. (author)

  18. Can reliable sage-grouse lek counts be obtained using aerial infrared technology

    Science.gov (United States)

    Gillette, Gifford L.; Coates, Peter S.; Petersen, Steven; Romero, John P.

    2013-01-01

    More effective methods for counting greater sage-grouse (Centrocercus urophasianus) are needed to better assess population trends through enumeration or location of new leks. We describe an aerial infrared technique for conducting sage-grouse lek counts and compare this method with conventional ground-based lek count methods. During the breeding period in 2010 and 2011, we surveyed leks from fixed-winged aircraft using cryogenically cooled mid-wave infrared cameras and surveyed the same leks on the same day from the ground following a standard lek count protocol. We did not detect significant differences in lek counts between surveying techniques. These findings suggest that using a cryogenically cooled mid-wave infrared camera from an aerial platform to conduct lek surveys is an effective alternative technique to conventional ground-based methods, but further research is needed. We discuss multiple advantages to aerial infrared surveys, including counting in remote areas, representing greater spatial variation, and increasing the number of counted leks per season. Aerial infrared lek counts may be a valuable wildlife management tool that releases time and resources for other conservation efforts. Opportunities exist for wildlife professionals to refine and apply aerial infrared techniques to wildlife monitoring programs because of the increasing reliability and affordability of this technology.

  19. Factor V Leiden is associated with increased sperm count

    NARCIS (Netherlands)

    van Mens, T. E.; Joensen, U. N.; Bochdanovits, Z.; Takizawa, A.; Peter, J.; Jørgensen, N.; Szecsi, P. B.; Meijers, J. C. M.; Weiler, H.; Rajpert-de Meyts, E.; Repping, S.; Middeldorp, S.

    2017-01-01

    STUDY QUESTION: Is the thrombophilia mutation factor V Leiden (FVL) associated with an increased total sperm count? SUMMARY ANSWER: Carriers of FVL have a higher total sperm count than non-FVL-carriers, which could not be explained by genetic linkage or by observations in a FVL-mouse model. WHAT IS

  20. Standardization of Ga-68 by coincidence measurements, liquid scintillation counting and 4πγ counting.

    Science.gov (United States)

    Roteta, Miguel; Peyres, Virginia; Rodríguez Barquero, Leonor; García-Toraño, Eduardo; Arenillas, Pablo; Balpardo, Christian; Rodrígues, Darío; Llovera, Roberto

    2012-09-01

    The radionuclide (68)Ga is one of the few positron emitters that can be prepared in-house without the use of a cyclotron. It disintegrates to the ground state of (68)Zn partially by positron emission (89.1%) with a maximum energy of 1899.1 keV, and partially by electron capture (10.9%). This nuclide has been standardized in the frame of a cooperation project between the Radionuclide Metrology laboratories from CIEMAT (Spain) and CNEA (Argentina). Measurements involved several techniques: 4πβ-γ coincidences, integral gamma counting and Liquid Scintillation Counting using the triple to double coincidence ratio and the CIEMAT/NIST methods. Given the short half-life of the radionuclide assayed, a direct comparison between results from both laboratories was excluded and a comparison of experimental efficiencies of similar NaI detectors was used instead. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. Empirical Derivation of Correction Factors for Human Spiral Ganglion Cell Nucleus and Nucleolus Count Units.

    Science.gov (United States)

    Robert, Mark E; Linthicum, Fred H

    2016-01-01

    Profile count method for estimating cell number in sectioned tissue applies a correction factor for double count (resulting from transection during sectioning) of count units selected to represent the cell. For human spiral ganglion cell counts, we attempted to address apparent confusion between published correction factors for nucleus and nucleolus count units that are identical despite the role of count unit diameter in a commonly used correction factor formula. We examined a portion of human cochlea to empirically derive correction factors for the 2 count units, using 3-dimensional reconstruction software to identify double counts. The Neurotology and House Histological Temporal Bone Laboratory at University of California at Los Angeles. Using a fully sectioned and stained human temporal bone, we identified and generated digital images of sections of the modiolar region of the lower first turn of cochlea, identified count units with a light microscope, labeled them on corresponding digital sections, and used 3-dimensional reconstruction software to identify double-counted count units. For 25 consecutive sections, we determined that double-count correction factors for nucleus count unit (0.91) and nucleolus count unit (0.92) matched the published factors. We discovered that nuclei and, therefore, spiral ganglion cells were undercounted by 6.3% when using nucleolus count units. We determined that correction factors for count units must include an element for undercounting spiral ganglion cells as well as the double-count element. We recommend a correction factor of 0.91 for the nucleus count unit and 0.98 for the nucleolus count unit when using 20-µm sections. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.

  2. A computer simulation used to investigate optimization in low level counting

    International Nuclear Information System (INIS)

    Brown, R.C.; Kephart, G.S.

    1984-01-01

    The differential form of the interval distribution for randomly spaced events such as radioactive decay is represented as dP/sub t/=ae - /supat/dt, the Poisson distribution. As applied to radioactive decay, this states that the probability (dP/sub t/) of the duration of a particular interval (elapsed time between counts) will be between t and t+dt as a function of the count rate (a). Thus a logarithmic transformation of this probability distribution results in a linear function whose slope and intercept are defined by the count rate. The effort expended in defining the interval distribution of a given radiation measurement equates in the laboratory to measuring and accumulating discrete time intervals between events rather than the usual approach of counting events per unit time. It follows from basic information theory that this greater effort should result in an improved statistical confidence in determinations of the ''true'' count rate (a). Using a random number generator as an analog of the discrete decay event, the authors have devised a Monte Carlo approach to investigate application of the above theory to the low level counting situation. This investigative approach is well suited to sensitivity analyses such that any constraints on proposed optimization techniques can be well defined prior to introducing these methods into the counting requirements in the laboratory

  3. Decay counting in the age of AMS

    International Nuclear Information System (INIS)

    Arnold, J.R.

    1987-01-01

    Up to the advent of AMS, all the accomplishments of 14 C dating, and the studies of 10 Be and other long-lived radionuclides, were made by low-level decay counting, the technique pioneered by W.F. Libby. It will hardly be news to people at this conference that, while much was accomplished in the three decades when counting prevailed, the world has now changed decisively. I will try to give an account of where low-level counting was 'before the revolution', and of what its usefulness is today. There are still some remarkable examples of its application, the best being the neutrino experiment of Raymond Davis, and its potential successors. Some cosmogenic nuclides, whose half-lives are less than 10 3 yr, are still best measured by decay; this will continue unless the overall ion yield of AMS systems rises markedly from present levels. One long-lived nuclide, 53 Mn, is still best measured by neutron activation as 312-day 54 Mn, but this may not continue. (orig.)

  4. Accuracy in activation analysis: count rate effects

    International Nuclear Information System (INIS)

    Lindstrom, R.M.; Fleming, R.F.

    1980-01-01

    The accuracy inherent in activation analysis is ultimately limited by the uncertainty of counting statistics. When careful attention is paid to detail, several workers have shown that all systematic errors can be reduced to an insignificant fraction of the total uncertainty, even when the statistical limit is well below one percent. A matter of particular importance is the reduction of errors due to high counting rate. The loss of counts due to random coincidence (pulse pileup) in the amplifier and to digitization time in the ADC may be treated as a series combination of extending and non-extending dead times, respectively. The two effects are experimentally distinct. Live timer circuits in commercial multi-channel analyzers compensate properly for ADC dead time for long-lived sources, but not for pileup. Several satisfactory solutions are available, including pileup rejection and dead time correction circuits, loss-free ADCs, and computed corrections in a calibrated system. These methods are sufficiently reliable and well understood that a decaying source can be measured routinely with acceptably small errors at a dead time as high as 20 percent

  5. Decay counting in the age of AMS

    International Nuclear Information System (INIS)

    Arnold, J.R.

    1987-01-01

    Up to the advent of AMS, all the accomplishments of 14 C dating, and the studies of 10 Be and other long-lived radionuclides, were made by low-level decay counting, the technique pioneered by W.F. Libby. It will hardly be news to people at this conference that, while much was accomplished in the three decades when counting prevailed, the world has now changed decisively. He will try to give an account of where low-level counting was before the revolution, and of what its usefulness is today. There are still some remarkable examples of its application, the best being the neutrino experiment of Raymond Davis, and its potential successors. Some cosmogenic nuclides, whose half-lives are less than 10 3 yr, are still best measured by decay; this will continue unless the overall ion yield of AMS systems rises markedly from present levels. One long-lived nuclide, 53 Mn, is still best measured by neutron activation as 312-day 54 Mn, but this may not continue

  6. Experimental Study for Automatic Colony Counting System Based Onimage Processing

    Science.gov (United States)

    Fang, Junlong; Li, Wenzhe; Wang, Guoxin

    Colony counting in many colony experiments is detected by manual method at present, therefore it is difficult for man to execute the method quickly and accurately .A new automatic colony counting system was developed. Making use of image-processing technology, a study was made on the feasibility of distinguishing objectively white bacterial colonies from clear plates according to the RGB color theory. An optimal chromatic value was obtained based upon a lot of experiments on the distribution of the chromatic value. It has been proved that the method greatly improves the accuracy and efficiency of the colony counting and the counting result is not affected by using inoculation, shape or size of the colony. It is revealed that automatic detection of colony quantity using image-processing technology could be an effective way.

  7. Vote Counting as Mathematical Proof

    DEFF Research Database (Denmark)

    Schürmann, Carsten; Pattinson, Dirk

    2015-01-01

    then consists of a sequence (or tree) of rule applications and provides an independently checkable certificate of the validity of the result. This reduces the need to trust, or otherwise verify, the correctness of the vote counting software once the certificate has been validated. Using a rule...

  8. Recent progress with digital coincidence counting

    International Nuclear Information System (INIS)

    Butcher, K.S.A.; Watt, G.C.; Alexiev, D.

    1999-01-01

    Digital Coincidence Counting (DCC) is a new technique, based on the older method of analogue coincidence counting. It has been developed by ANSTO as a faster more reliable means of determining the activity of ionising radiation samples. The technique employs a dual channel analogue to digital converter acquisition system for collecting pulse information from a 4Π beta detector and a NaI(Tl) gamma detector. The digitised pulse information is stored on a high speed hard disk and timing information for both channels is also stored. The data may subsequently be recalled and analysed using software based algorithms. The system is operational and results are now being routinely collected and analysed. Some of the early work is presented for Co-60, Na-22 and Sm-153

  9. Bayesian Kernel Mixtures for Counts.

    Science.gov (United States)

    Canale, Antonio; Dunson, David B

    2011-12-01

    Although Bayesian nonparametric mixture models for continuous data are well developed, there is a limited literature on related approaches for count data. A common strategy is to use a mixture of Poissons, which unfortunately is quite restrictive in not accounting for distributions having variance less than the mean. Other approaches include mixing multinomials, which requires finite support, and using a Dirichlet process prior with a Poisson base measure, which does not allow smooth deviations from the Poisson. As a broad class of alternative models, we propose to use nonparametric mixtures of rounded continuous kernels. An efficient Gibbs sampler is developed for posterior computation, and a simulation study is performed to assess performance. Focusing on the rounded Gaussian case, we generalize the modeling framework to account for multivariate count data, joint modeling with continuous and categorical variables, and other complications. The methods are illustrated through applications to a developmental toxicity study and marketing data. This article has supplementary material online.

  10. Liquid scintillation: Sample preparation and counting atypical emissions

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    Liquid scintillation sample preparation has the most published information but the least amount of definitive technical direction because the chemical and physical nature of the samples from biological investigations varies widely. This chapter discusses the following related topics: Aqueous Samples; Tissue Solubilizers; Absorption of 14 CO 2 ; Sample Combustion Methods; Heterogeneous Systems; Sample Preparation Problems (colored samples, chemiluminescence, photoluminescence, static electricity); Counting Various Types of Emitters; Counting Atypical Emissions. 2 refs., 2 figs

  11. Differential white cell count by centrifugal microfluidics.

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, Gregory Jon; Tentori, Augusto M.; Schaff, Ulrich Y.

    2010-07-01

    We present a method for counting white blood cells that is uniquely compatible with centrifugation based microfluidics. Blood is deposited on top of one or more layers of density media within a microfluidic disk. Spinning the disk causes the cell populations within whole blood to settle through the media, reaching an equilibrium based on the density of each cell type. Separation and fluorescence measurement of cell types stained with a DNA dye is demonstrated using this technique. The integrated signal from bands of fluorescent microspheres is shown to be proportional to their initial concentration in suspension. Among the current generation of medical diagnostics are devices based on the principle of centrifuging a CD sized disk functionalized with microfluidics. These portable 'lab on a disk' devices are capable of conducting multiple assays directly from a blood sample, embodied by platforms developed by Gyros, Samsung, and Abaxis. [1,2] However, no centrifugal platform to date includes a differential white blood cell count, which is an important metric complimentary to diagnostic assays. Measuring the differential white blood cell count (the relative fraction of granulocytes, lymphocytes, and monocytes) is a standard medical diagnostic technique useful for identifying sepsis, leukemia, AIDS, radiation exposure, and a host of other conditions that affect the immune system. Several methods exist for measuring the relative white blood cell count including flow cytometry, electrical impedance, and visual identification from a stained drop of blood under a microscope. However, none of these methods is easily incorporated into a centrifugal microfluidic diagnostic platform.

  12. Calibration of a liquid scintillation counter for alpha, beta and Cerenkov counting

    International Nuclear Information System (INIS)

    Scarpitta, S.C.; Fisenne, I.M.

    1996-07-01

    Calibration data are presented for 25 radionuclides that were individually measured in a Packard Tri-Carb 2250CA liquid scintillation (LS) counter by both conventional and Cerenkov detection techniques. The relationships and regression data between the quench indicating parameters and the LS counting efficiencies were determined using microliter amounts of tracer added to low 40 K borosilicate glass vials containing 15 mL of Insta-Gel XF scintillation cocktail. Using 40 K, the detection efficiencies were linear over a three order of magnitude range (10 - 10,000 mBq) in beta activity for both LS and Cerenkov counting. The Cerenkov counting efficiency (CCE) increased linearly (42% per MeV) from 0.30 to 2.0 MeV, whereas the LS efficiency was >90% for betas with energy in excess of 0.30 MeV. The CCE was 20 - 50% less than the LS counting efficiency for beta particles with maximum energies in excess of 1 MeV. Based on replicate background measurements, the lower limit of detection (LLD) for a 1-h count at the 95% confidence level, using water as a solvent, was 0.024 counts sec- -1 and 0.028 counts sec-1 for plastic and glass vials, respectively. The LLD for a 1-h-count ranged from 46 to 56 mBq (2.8 - 3.4 dpm) for both Cerenkov and conventional LS counting. This assumes: (1) a 100% counting efficiency, (2) a 50% yield of the nuclide of interest, (3) a 1-h measurement time using low background plastic vials, and (4) a 0-50 keV region of interest. The LLD is reduced an order of magnitude when the yield recovery exceeds 90% and a lower background region is used (i.e., 100 - 500 keV alpha region of interest). Examples and applications of both Cerenkov and LS counting techniques are given in the text and appendices

  13. The distribution of controlled drugs on banknotes via counting machines.

    Science.gov (United States)

    Carter, James F; Sleeman, Richard; Parry, Joanna

    2003-03-27

    Bundles of paper, similar to sterling banknotes, were counted in banks in England and Wales. Subsequent analysis showed that the counting process, both by machine and by hand, transferred nanogram amounts of cocaine to the paper. Crystalline material, similar to cocaine hydrochloride, could be observed on the surface of the paper following counting. The geographical distribution of contamination broadly followed Government statistics for cocaine usage within the UK. Diacetylmorphine, Delta(9)-tetrahydrocannabinol (THC) and 3,4-methylenedioxymethylamphetamine (MDMA) were not detected during this study.

  14. Scale-dependent associations of Band-tailed Pigeon counts at mineral sites

    Science.gov (United States)

    Overton, Cory T.; Casazza, Michael L.; Coates, Peter S.

    2010-01-01

    The abundance of Band-tailed Pigeons (Patagioenas fasciata monilis) has declined substantially from historic numbers along the Pacific Coast. Identification of patterns and causative factors of this decline are hampered because habitat use data are limited, and temporal and spatial variability patterns associated with population indices are not known. Furthermore, counts are influenced not only by pigeon abundance but also by rate of visitation to mineral sites, which may not be consistent. To address these issues, we conducted mineral site counts during 2001 and 2002 at 20 locations from 4 regions in the Pacific Northwest, including central Oregon and western Washington, USA, and British Columbia, Canada. We developed inference models that consisted of environmental factors and spatial characteristics at multiple spatial scales. Based on information theory, we compared models within a final set that included variables measured at 3 spatial scales (0.03 ha, 3.14 ha, and 7850 ha). Pigeon counts increased from central Oregon through northern Oregon and decreased into British Columbia. After accounting for this spatial pattern, we found that pigeon counts increased 12% ± 2.7 with a 10% increase in the amount of deciduous forested area within 100 m from a mineral site. Also, distance from the mineral site of interest to the nearest known mineral site was positively related to pigeon counts. These findings provide direction for future research focusing on understanding the relationships between indices of relative abundance and complete counts (censuses) of pigeon populations by identifying habitat characteristics that might influence visitation rates. Furthermore, our results suggest that spatial arrangement of mineral sites influences Band-tailed Pigeon counts and the populations which those counts represent.

  15. Development of an automated asbestos counting software based on fluorescence microscopy.

    Science.gov (United States)

    Alexandrov, Maxym; Ichida, Etsuko; Nishimura, Tomoki; Aoki, Kousuke; Ishida, Takenori; Hirota, Ryuichi; Ikeda, Takeshi; Kawasaki, Tetsuo; Kuroda, Akio

    2015-01-01

    An emerging alternative to the commonly used analytical methods for asbestos analysis is fluorescence microscopy (FM), which relies on highly specific asbestos-binding probes to distinguish asbestos from interfering non-asbestos fibers. However, all types of microscopic asbestos analysis require laborious examination of large number of fields of view and are prone to subjective errors and large variability between asbestos counts by different analysts and laboratories. A possible solution to these problems is automated counting of asbestos fibers by image analysis software, which would lower the cost and increase the reliability of asbestos testing. This study seeks to develop a fiber recognition and counting software for FM-based asbestos analysis. We discuss the main features of the developed software and the results of its testing. Software testing showed good correlation between automated and manual counts for the samples with medium and high fiber concentrations. At low fiber concentrations, the automated counts were less accurate, leading us to implement correction mode for automated counts. While the full automation of asbestos analysis would require further improvements in accuracy of fiber identification, the developed software could already assist professional asbestos analysts and record detailed fiber dimensions for the use in epidemiological research.

  16. Cherenkov radiation effects on counting efficiency in extremely quenched liquid scintillation samples

    International Nuclear Information System (INIS)

    Grau Carles, A.; Grau Malonda, A.; Rodriguez Barquero, L.

    1993-01-01

    The CIEMAT/NIST tracer method has successfully standardized nuclides with diverse quench values and decay schemes in liquid scintillation counting. However, the counting efficiency is computed inaccurately for extremely quenched samples. This article shows that when samples are extremely quenched, the counting efficiency in high-energy beta-ray nuclides depends principally on the Cherenkov effect. A new technique is described for quench determination, which makes the measurement of counting efficiency possible when scintillation counting approaches zero. A new efficiency computation model for pure beta-ray nuclides is also described. The results of the model are tested experimentally for 89 Sr, 90 Y, 36 Cl and 204 Tl nuclides with independence of the quench level. (orig.)

  17. Compositions and process for liquid scintillation counting

    International Nuclear Information System (INIS)

    1974-01-01

    Liquid scintillation counting compositions which include certain polyethoxylated poly(oxypropylene) emulsifiers allow stable dispersion of aqueous or other samples merely by shaking. Preferred are mixtures of such emulsifiers which give homogeneous monophasic-appearing dispersions over wide ranges of temperature and aqueous sample content. Certain of these emulsifiers, without being mixed, are of particular advantage when used in analysis of samples obtained through radioimmunoassay techniques which are extremely difficult to disperse. Certain of these emulsifiers, also without being mixed, uniformly give homogeneous monophasic-appearing aqueous counting samples over much wider ranges of aqueous sample content and temperature than prior sample emulsifiers

  18. Quantitative monitoring of the fluorination process by neutron counting

    International Nuclear Information System (INIS)

    Russo, P.A.; Appert, Q.D.; Biddle, R.S.; Kelley, T.A.; Martinez, M.M.; West, M.H.

    1993-01-01

    Plutonium metal is produced by reducing PuF 4 prepared from PuO 2 by fluorination. Both fluorination and reduction are batch processes at the Los Alamos Plutonium Facility. The conversion of plutonium oxide to fluoride greatly increases the neutron yield, a result of the high cross section for alpha-neutron (α,n) reactions on fluorine targets compared to the (more than 100 times) smaller α,n yield on oxygen targets. Because of the increase, total neutron counting can be used to monitor the conversion process. This monitoring ability can lead to an improved metal product, reduced scrap for recycle, waste reduction, minimized reagent usage, and reduce personnel radiation exposures. A new stirred-bed fluorination process has been developed simultaneously with a recent evaluation of an automated neutron-counting instrument for quantitative process monitoring. Neutrons are counted with polyethylene-moderated 3 He-gas proportional counters. Results include a calibration of the real-time neutron-count-rate indicator for the extent of fluorination using reference values obtained from destructive analysis of samples from the blended fluoroinated batch

  19. Eosinophil count, allergies, and rejection in pediatric heart transplant recipients.

    Science.gov (United States)

    Arbon, Kate S; Albers, Erin; Kemna, Mariska; Law, Sabrina; Law, Yuk

    2015-08-01

    Allograft rejection and long-term immunosuppression remain significant challenges in pediatric heart transplantation. Pediatric recipients are known to have fewer rejection episodes and to develop more allergic conditions than adults. A T-helper 2 cell dominant phenotype, manifested clinically by allergies and an elevated eosinophil count, may be associated with immunologic quiescence in transplant recipients. This study assessed whether the longitudinal eosinophil count and an allergic phenotype were associated with freedom from rejection. This single-center, longitudinal, observational study included 86 heart transplant patients monitored from 1994 to 2011. Post-transplant biannual complete blood counts, allergic conditions, and clinical characteristics related to rejection risk were examined. At least 1 episode of acute cellular rejection (ACR) occurred in 38 patients (44%), antibody-mediated rejection (AMR) occurred in 11 (13%), and 49 patients (57%) were diagnosed with an allergic condition. Patients with ACR or AMR had a lower eosinophil count compared with non-rejectors (p = 0.011 and p = 0.022, respectively). In the multivariable regression analysis, the presence of panel reactive antibodies to human leukocyte antigen I (p = 0.014) and the median eosinophil count (p = 0.011) were the only independent covariates associated with AMR. Eosinophil count (p = 0.010) and female sex (p = 0.009) were independent risk factors for ACR. Allergic conditions or young age at transplant were not protective from rejection. This study demonstrates a novel association between a high eosinophil count and freedom from rejection. Identifying a biomarker for low rejection risk may allow a reduction in immunosuppression. Further investigation into the role of the T-helper 2 cell phenotype and eosinophils in rejection quiescence is warranted. Copyright © 2015 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  20. A measurement technique for counting processes

    International Nuclear Information System (INIS)

    Cantoni, V.; Pavia Univ.; De Lotto, I.; Valenziano, F.

    1980-01-01

    A technique for the estimation of first and second order properties of a stationary counting process is presented here which uses standard instruments for analysis of a continuous stationary random signal. (orig.)

  1. VSRR Provisional Drug Overdose Death Counts

    Data.gov (United States)

    U.S. Department of Health & Human Services — This data contains provisional counts for drug overdose deaths based on a current flow of mortality data in the National Vital Statistics System. National...

  2. Effective dark count rate reduction by modified SPAD gating circuit

    Energy Technology Data Exchange (ETDEWEB)

    Prochazka, Ivan; Blazej, Josef, E-mail: blazej@fjfi.cvut.cz; Kodet, Jan

    2015-07-01

    For our main application of single photon counting avalanche detectors in focus – laser ranging of space objects and laser time transfer – the ultimate requirements are relatively large and homogeneous active area having a diameter of 100 to 200 µm and a sub-picosecond stability of timing. The detector dark count rate and after-pulsing probability are parameters of relatively lower, but not negligible importance. In presented paper we will focused on them. We have developed a new active quenching and gating scheme which can reduce afterpulsing effect and hence also effective dark count rate at lower temperature. In satellite laser ranging system the effective dark count rate was reduced more than 35 times. This improvement will contribute in increasing the data yield and hence to increase precision and productivity. - Highlights: • Signal and quenching path in a control circuit stayed unaffected by gating. • The detector package optimized for laser time transfer systems is considered. • After-pulsing effect is reduced by a modification of the use of gate signal. • The dark count rate is reduced for gate rates of the order of units of kHz.

  3. Average sperm count remains unchanged despite reduction in maternal smoking

    DEFF Research Database (Denmark)

    Priskorn, L; Nordkap, L; Bang, A K

    2018-01-01

    STUDY QUESTION: How are temporal trends in lifestyle factors, including exposure to maternal smoking in utero, associated to semen quality in young men from the general population? SUMMARY ANSWER: Exposure to maternal smoking was associated with lower sperm counts but no overall increase in sperm...... temporal trends. Parental age increased, and exposure in utero to maternal smoking declined from 40% among men investigated in 1996-2000 to 18% among men investigated in 2011-2016. Exposure to maternal smoking was associated with lower sperm counts but no overall increase in sperm counts was observed...... counts was observed during the study period despite a decrease in this exposure. WHAT IS KNOWN ALREADY: Meta-analyses suggest a continuous decline in semen quality but few studies have investigated temporal trends in unselected populations recruited and analysed with the same protocol over a long period...

  4. Nearest neighbors by neighborhood counting.

    Science.gov (United States)

    Wang, Hui

    2006-06-01

    Finding nearest neighbors is a general idea that underlies many artificial intelligence tasks, including machine learning, data mining, natural language understanding, and information retrieval. This idea is explicitly used in the k-nearest neighbors algorithm (kNN), a popular classification method. In this paper, this idea is adopted in the development of a general methodology, neighborhood counting, for devising similarity functions. We turn our focus from neighbors to neighborhoods, a region in the data space covering the data point in question. To measure the similarity between two data points, we consider all neighborhoods that cover both data points. We propose to use the number of such neighborhoods as a measure of similarity. Neighborhood can be defined for different types of data in different ways. Here, we consider one definition of neighborhood for multivariate data and derive a formula for such similarity, called neighborhood counting measure or NCM. NCM was tested experimentally in the framework of kNN. Experiments show that NCM is generally comparable to VDM and its variants, the state-of-the-art distance functions for multivariate data, and, at the same time, is consistently better for relatively large k values. Additionally, NCM consistently outperforms HEOM (a mixture of Euclidean and Hamming distances), the "standard" and most widely used distance function for multivariate data. NCM has a computational complexity in the same order as the standard Euclidean distance function and NCM is task independent and works for numerical and categorical data in a conceptually uniform way. The neighborhood counting methodology is proven sound for multivariate data experimentally. We hope it will work for other types of data.

  5. The real-time fitting of radioactive decay curves. Pt. 3. Counting during sampling

    International Nuclear Information System (INIS)

    Hartley, B.M.

    1994-01-01

    An analysis of a least-squares method for the real-time fitting of the theoretical total count function to the actual total count from radioactive decays has been given previously for the case where counting takes place after a sample is taken. The counting may be done in a number of different counting systems which distinguish between different types or energies of radiation emitted from the sample. The method would allow real-time determination of the numbers of atoms and hence activities of the individual isotopes present and has been designated the Time Evolved Least-Squares method (TELS). If the radioactivity which is to be measured exists as an aerosol or in a form where a sample is taken at a constant rate it may be possible to count during sampling and by so doing reduce the total time required to determine the activity of the individual isotopes present. The TELS method is extended here to the case where counting and the evaluation of the activity takes place concurrently with the sampling. The functions which need to be evaluated are derived and the calculations required to implement the method are discussed. As with the TELS method of counting after sampling the technique of counting during sampling and the simultaneous evaluation of activity could be achieved in real-time. Results of testing the method by computer simulation for two counting schemes for the descendants of radon are presented. ((orig.))

  6. Maximum entropy deconvolution of low count nuclear medicine images

    International Nuclear Information System (INIS)

    McGrath, D.M.

    1998-12-01

    Maximum entropy is applied to the problem of deconvolving nuclear medicine images, with special consideration for very low count data. The physics of the formation of scintigraphic images is described, illustrating the phenomena which degrade planar estimates of the tracer distribution. Various techniques which are used to restore these images are reviewed, outlining the relative merits of each. The development and theoretical justification of maximum entropy as an image processing technique is discussed. Maximum entropy is then applied to the problem of planar deconvolution, highlighting the question of the choice of error parameters for low count data. A novel iterative version of the algorithm is suggested which allows the errors to be estimated from the predicted Poisson mean values. This method is shown to produce the exact results predicted by combining Poisson statistics and a Bayesian interpretation of the maximum entropy approach. A facility for total count preservation has also been incorporated, leading to improved quantification. In order to evaluate this iterative maximum entropy technique, two comparable methods, Wiener filtering and a novel Bayesian maximum likelihood expectation maximisation technique, were implemented. The comparison of results obtained indicated that this maximum entropy approach may produce equivalent or better measures of image quality than the compared methods, depending upon the accuracy of the system model used. The novel Bayesian maximum likelihood expectation maximisation technique was shown to be preferable over many existing maximum a posteriori methods due to its simplicity of implementation. A single parameter is required to define the Bayesian prior, which suppresses noise in the solution and may reduce the processing time substantially. Finally, maximum entropy deconvolution was applied as a pre-processing step in single photon emission computed tomography reconstruction of low count data. Higher contrast results were

  7. Determining reactor fuel elements broken by Cerenkov counting

    International Nuclear Information System (INIS)

    Guo Juhao; Dong Shiyuan; Feng Yuying

    1996-01-01

    The basis and method of determining fuel elements broken in a reactor by Cerenkov counting measured with liquid scintillation spectrometer are introduced. The radioactive characteristic of the radiation nuclides generating Cherenkov radiation in the primary water of 200 MW nuclear district heating reactor is analyzed. The activity of the activation products in the primary water and the fission products in the fuel elements are calculated. A feasibility of Cerenkov counting measure was analyzed. This method is simple and quick

  8. CERN{sub D}xCTA counting mode chip

    Energy Technology Data Exchange (ETDEWEB)

    Moraes, D. [CERN, CH-1211 Geneva 23 (Switzerland)], E-mail: danielle.moraes@cern.ch; Kaplon, J. [CERN, CH-1211 Geneva 23 (Switzerland); Nygard, E. [Interon AS, Asker, Norway and DX-ray Inc., Northridge, CA (United States)

    2008-06-11

    This ASIC is a counting mode front-end electronic optimized for the readout of CdZnTe/CdTe and silicon sensors, for possible use in applications where the flux of ionizing radiation is high. The chip is implemented in 0.25 {mu}m CMOS technology. The circuit comprises 128 channels equipped with a transimpedance amplifier followed by a gain shaper stage with 21 ns peaking time, two discriminators and two 18-bit counters. The channel architecture is optimized for the detector characteristics in order to achieve the best energy resolution at counting rates of up to 5 M counts/second. The amplifier shows a linear sensitivity of 118 mV/fC and an equivalent noise charge of about 711 e{sup -}, for a detector capacitance of 5 pF. Complete evaluation of the circuit is presented using electronic pulses and pixel detectors.

  9. Atom counting with accelerator mass spectrometry

    International Nuclear Information System (INIS)

    Kutschera, Walter

    1995-01-01

    A brief review of the current status and some recent applications of accelerator mass spectrometry (AMS) are presented. Some connections to resonance ionization mass spectroscopy (RIS) as the alternate atom counting method are discussed

  10. NMR metabolomics of esca disease-affected Vitis vinifera cv. Alvarinho leaves.

    Science.gov (United States)

    Lima, Marta R M; Felgueiras, Mafalda L; Graça, Gonçalo; Rodrigues, João E A; Barros, António; Gil, Ana M; Dias, Alberto C P

    2010-09-01

    Esca is a destructive disease that affects vineyards leading to important losses in wine production. Information about the response of Vitis vinifera plants to this disease is scarce, particularly concerning changes in plant metabolism. In order to study the metabolic changes in Vitis plants affected by esca, leaves from both infected and non-affected cordons of V. vinifera cv. Alvarinho (collected in the Vinho Verde region, Portugal) were analysed. The metabolite composition of leaves from infected cordons with visible symptoms [diseased leaves (dl)] and from asymptomatic cordons [healthy leaves (hl)] was evaluated by 1D and 2D (1)H-nuclear magnetic resonance (NMR) spectroscopy. Principal component analysis (PCA) of the NMR spectra showed a clear separation between dl and hl leaves, indicating differential compound production due to the esca disease. NMR/PCA analysis allowed the identification of specific compounds characterizing each group, and the corresponding metabolic pathways are discussed. Altogether, the study revealed a significant increase of phenolic compounds in dl, compared with hl, accompanied by a decrease in carbohydrates, suggesting that dl are rerouting carbon and energy from primary to secondary metabolism. Other metabolic alterations detected comprised increased levels of methanol, alanine, and gamma-aminobutyric acid in dl, which might be the result of the activation of other defence mechanisms.

  11. Determination of phosphorus-32 in wet-digested plant leaves by Cerenkov counting

    International Nuclear Information System (INIS)

    Wahid, P.A.; Kamalam, N.V.; Sankar, S.J.

    1985-01-01

    A method of determination of 32 P activity in leaf samples by Cerenkov counting technique is described. The method involves wet digestion of oven-dried leaves with 1:1 nitric-perchloric acid mixture followed by transferring the digest into a scintillation counting vial with distilled water upto a final volume of 20 mL, and determining the activity in a liquid scintillation system. Reproducible count rates can be obtained if the vials are counted after 4h allowing the silica in the digest to settle. (author)

  12. Counting on dis-inhibition: a circuit motif for interval counting and selectivity in the anuran auditory system.

    Science.gov (United States)

    Naud, Richard; Houtman, Dave; Rose, Gary J; Longtin, André

    2015-11-01

    Information can be encoded in the temporal patterning of spikes. How the brain reads these patterns is of general importance and represents one of the greatest challenges in neuroscience. We addressed this issue in relation to temporal pattern recognition in the anuran auditory system. Many species of anurans perform mating decisions based on the temporal structure of advertisement calls. One important temporal feature is the number of sound pulses that occur with a species-specific interpulse interval. Neurons representing this pulse count have been recorded in the anuran inferior colliculus, but the mechanisms underlying their temporal selectivity are incompletely understood. Here, we construct a parsimonious model that can explain the key dynamical features of these cells with biologically plausible elements. We demonstrate that interval counting arises naturally when combining interval-selective inhibition with pulse-per-pulse excitation having both fast- and slow-conductance synapses. Interval-dependent inhibition is modeled here by a simple architecture based on known physiology of afferent nuclei. Finally, we consider simple implementations of previously proposed mechanistic explanations for these counting neurons and show that they do not account for all experimental observations. Our results demonstrate that tens of millisecond-range temporal selectivities can arise from simple connectivity motifs of inhibitory neurons, without recourse to internal clocks, spike-frequency adaptation, or appreciable short-term plasticity. Copyright © 2015 the American Physiological Society.

  13. Sources and magnitude of sampling error in redd counts for bull trout

    Science.gov (United States)

    Jason B. Dunham; Bruce Rieman

    2001-01-01

    Monitoring of salmonid populations often involves annual redd counts, but the validity of this method has seldom been evaluated. We conducted redd counts of bull trout Salvelinus confluentus in two streams in northern Idaho to address four issues: (1) relationships between adult escapements and redd counts; (2) interobserver variability in redd...

  14. CoC Housing Inventory Count Reports

    Data.gov (United States)

    Department of Housing and Urban Development — Continuum of Care (CoC) Homeless Assistance Programs Housing Inventory Count Reports are a snapshot of a CoC’s housing inventory, available at the national and state...

  15. A Method for Counting Moving People in Video Surveillance Videos

    Directory of Open Access Journals (Sweden)

    Mario Vento

    2010-01-01

    Full Text Available People counting is an important problem in video surveillance applications. This problem has been faced either by trying to detect people in the scene and then counting them or by establishing a mapping between some scene feature and the number of people (avoiding the complex detection problem. This paper presents a novel method, following this second approach, that is based on the use of SURF features and of an ϵ-SVR regressor provide an estimate of this count. The algorithm takes specifically into account problems due to partial occlusions and to perspective. In the experimental evaluation, the proposed method has been compared with the algorithm by Albiol et al., winner of the PETS 2009 contest on people counting, using the same PETS 2009 database. The provided results confirm that the proposed method yields an improved accuracy, while retaining the robustness of Albiol's algorithm.

  16. A Method for Counting Moving People in Video Surveillance Videos

    Directory of Open Access Journals (Sweden)

    Conte Donatello

    2010-01-01

    Full Text Available People counting is an important problem in video surveillance applications. This problem has been faced either by trying to detect people in the scene and then counting them or by establishing a mapping between some scene feature and the number of people (avoiding the complex detection problem. This paper presents a novel method, following this second approach, that is based on the use of SURF features and of an -SVR regressor provide an estimate of this count. The algorithm takes specifically into account problems due to partial occlusions and to perspective. In the experimental evaluation, the proposed method has been compared with the algorithm by Albiol et al., winner of the PETS 2009 contest on people counting, using the same PETS 2009 database. The provided results confirm that the proposed method yields an improved accuracy, while retaining the robustness of Albiol's algorithm.

  17. A Method for Counting Moving People in Video Surveillance Videos

    Science.gov (United States)

    Conte, Donatello; Foggia, Pasquale; Percannella, Gennaro; Tufano, Francesco; Vento, Mario

    2010-12-01

    People counting is an important problem in video surveillance applications. This problem has been faced either by trying to detect people in the scene and then counting them or by establishing a mapping between some scene feature and the number of people (avoiding the complex detection problem). This paper presents a novel method, following this second approach, that is based on the use of SURF features and of an [InlineEquation not available: see fulltext.]-SVR regressor provide an estimate of this count. The algorithm takes specifically into account problems due to partial occlusions and to perspective. In the experimental evaluation, the proposed method has been compared with the algorithm by Albiol et al., winner of the PETS 2009 contest on people counting, using the same PETS 2009 database. The provided results confirm that the proposed method yields an improved accuracy, while retaining the robustness of Albiol's algorithm.

  18. Investigating Children's Abilities to Count and Make Quantitative Comparisons

    Science.gov (United States)

    Lee, Joohi; Md-Yunus, Sham'ah

    2016-01-01

    This study was designed to investigate children's abilities to count and make quantitative comparisons. In addition, this study utilized reasoning questions (i.e., how did you know?). Thirty-four preschoolers, mean age 4.5 years old, participated in the study. According to the results, 89% of the children (n = 30) were able to do rote counting and…

  19. Passive hand movements disrupt adults' counting strategies.

    Science.gov (United States)

    Imbo, Ineke; Vandierendonck, André; Fias, Wim

    2011-01-01

    In the present study, we experimentally tested the role of hand motor circuits in simple-arithmetic strategies. Educated adults solved simple additions (e.g., 8 + 3) or simple subtractions (e.g., 11 - 3) while they were required to retrieve the answer from long-term memory (e.g., knowing that 8 + 3 = 11), to transform the problem by making an intermediate step (e.g., 8 + 3 = 8 + 2 + 1 = 10 + 1 = 11) or to count one-by-one (e.g., 8 + 3 = 8…9…10…11). During the process of solving the arithmetic problems, the experimenter did or did not move the participants' hand on a four-point matrix. The results show that passive hand movements disrupted the counting strategy while leaving the other strategies unaffected. This pattern of results is in agreement with a procedural account, showing that the involvement of hand motor circuits in adults' mathematical abilities is reminiscent of finger counting during childhood.

  20. On temporal correlations in high-resolution frequency counting

    OpenAIRE

    Dunker, Tim; Hauglin, Harald; Rønningen, Ole Petter

    2016-01-01

    We analyze noise properties of time series of frequency data from different counting modes of a Keysight 53230A frequency counter. We use a 10 MHz reference signal from a passive hydrogen maser connected via phase-stable Huber+Suhner Sucoflex 104 cables to the reference and input connectors of the counter. We find that the high resolution gap-free (CONT) frequency counting process imposes long-term correlations in the output data, resulting in a modified Allan deviation that is characteristic...

  1. Pulse mode counting system with parallel port interface

    International Nuclear Information System (INIS)

    Farooq, M.A.; Mushtaq, N.; Sultan, M.; Karim, A.

    2010-11-01

    Pulse mode Counting System (PPCS) module has been designed and developed which is compatible with SPP (Standard Parallel Port) and EPP Enhanced Parallel Port). This system can capture, present and store real time data in a well formatted form. The stored data is in a format that can be imported in different packages for further analysis. The purpose of this system is to facilitate the research experiments having frequency range up to 4 MHz and storing range up to 16 million counts. (author)

  2. Generating ActiGraph counts from raw acceleration recorded by an alternative monitor

    DEFF Research Database (Denmark)

    Brønd, Jan Christian; Andersen, Lars Bo; Arvidsson, Daniel

    2017-01-01

    Introduction: Raw acceleration data collected by the ActiGraph accelerometer is aggregated using a proprietary method into arbitrary physical activity intensity units called counts, which has been extensively calibrated and validated against energy expenditure. Generating ActiGraph counts from any...... second across all rotational frequencies compared to the original ActiGraph method. Applying the aggregation method to the 24-hour free-living recordings resulted in an epoch level bias ranging from -16.2 to 0.9 counts per 10 second, a relative difference in the averaged physical activity (counts per...

  3. Pitch Counts in Youth Baseball and Softball: A Historical Review.

    Science.gov (United States)

    Feeley, Brian T; Schisel, Jessica; Agel, Julie

    2018-07-01

    Pitching injuries are getting increased attention in the mass media. Many references are made to pitch counts and the role they play in injury prevention. The original purpose of regulating the pitch count in youth baseball was to reduce injury and fatigue to pitchers. This article reviews the history and development of the pitch count limit in baseball, the effect it has had on injury, and the evidence regarding injury rates on softball windmill pitching. Literature search through PubMed, mass media, and organizational Web sites through June 2015. Pitch count limits and rest recommendations were introduced in 1996 after a survey of 28 orthopedic surgeons and baseball coaches showed injuries to baseball pitchers' arms were believed to be from the number of pitches thrown. Follow-up research led to revised recommendations with more detailed guidelines in 2006. Since that time, data show a relationship between innings pitched and upper extremity injury, but pitch type has not clearly been shown to affect injury rates. Current surveys of coaches and players show that coaches, parents, and athletes often do not adhere to these guidelines. There are no pitch count guidelines currently available in softball. The increase in participation in youth baseball and softball with an emphasis on early sport specialization in youth sports activities suggests that there will continue to be a rise in injury rates to young throwers. The published pitch counts are likely to positively affect injury rates but must be adhered to by athletes, coaches, and parents.

  4. Counting dyons in N=4 string theory

    CERN Document Server

    Dijkgraaf, R; Verlinde, Herman L

    1997-01-01

    We present a microscopic index formula for the degeneracy of dyons in four-dimensional N=4 string theory. This counting formula is manifestly symmetric under the duality group, and its asymptotic growth reproduces the macroscopic Bekenstein-Hawking entropy. We give a derivation of this result in terms of the type II five-brane compactified on K3, by assuming that its fluctuations are described by a closed string theory on its world-volume. We find that the degeneracies are given in terms of the denominator of a generalized super Kac-Moody algebra. We also discuss the correspondence of this result with the counting of D-brane states.

  5. Reviving common standards in point-count surveys for broad inference across studies

    Science.gov (United States)

    Matsuoka, Steven M.; Mahon, C. Lisa; Handel, Colleen M.; Solymos, Peter; Bayne, Erin M.; Fontaine, Patricia C.; Ralph, C.J.

    2014-01-01

    We revisit the common standards recommended by Ralph et al. (1993, 1995a) for conducting point-count surveys to assess the relative abundance of landbirds breeding in North America. The standards originated from discussions among ornithologists in 1991 and were developed so that point-count survey data could be broadly compared and jointly analyzed by national data centers with the goals of monitoring populations and managing habitat. Twenty years later, we revisit these standards because (1) they have not been universally followed and (2) new methods allow estimation of absolute abundance from point counts, but these methods generally require data beyond the original standards to account for imperfect detection. Lack of standardization and the complications it introduces for analysis become apparent from aggregated data. For example, only 3% of 196,000 point counts conducted during the period 1992-2011 across Alaska and Canada followed the standards recommended for the count period and count radius. Ten-minute, unlimited-count-radius surveys increased the number of birds detected by >300% over 3-minute, 50-m-radius surveys. This effect size, which could be eliminated by standardized sampling, was ≥10 times the published effect sizes of observers, time of day, and date of the surveys. We suggest that the recommendations by Ralph et al. (1995a) continue to form the common standards when conducting point counts. This protocol is inexpensive and easy to follow but still allows the surveys to be adjusted for detection probabilities. Investigators might optionally collect additional information so that they can analyze their data with more flexible forms of removal and time-of-detection models, distance sampling, multiple-observer methods, repeated counts, or combinations of these methods. Maintaining the common standards as a base protocol, even as these study-specific modifications are added, will maximize the value of point-count data, allowing compilation and

  6. An Economical Fast Discriminator for Nuclear Pulse Counting

    International Nuclear Information System (INIS)

    Issarachai, Opas; Punnachaiya, Suvit

    2009-07-01

    Full text: This research work was aimed to develop a fast discriminator at low cost but high capability for discrimination a nanosecond nuclear pulse. The fast discriminator can be used in association with fast photon counting system. The designed structure consisted of the ultra-fast voltage comparator using ADCMP601 integrated circuit, the monostable multivibrator with controllable pulse width output by propagation delay of logic gate, and the fast response buffer amplifier. The tested results of pulse height discrimination of 0-5 V nuclear pulse with 20 ns (FWHM) pulse width showed the correlation coefficient (R 2 ) between discrimination level and pulse height was 0.998, while the pulse rate more than 10 MHz could be counted. The 30 ns logic pulse width output revealed high stable and could be smoothly driven to low impedance load at 50 Ω. For pulse signal transmission to the counter, it was also found that the termination of reflected signal must be considered because it may cause pulse counting error

  7. Cache-Oblivious Planar Orthogonal Range Searching and Counting

    DEFF Research Database (Denmark)

    Arge, Lars; Brodal, Gerth Stølting; Fagerberg, Rolf

    2005-01-01

    present the first cache-oblivious data structure for planar orthogonal range counting, and improve on previous results for cache-oblivious planar orthogonal range searching. Our range counting structure uses O(Nlog2 N) space and answers queries using O(logB N) memory transfers, where B is the block...... size of any memory level in a multilevel memory hierarchy. Using bit manipulation techniques, the space can be further reduced to O(N). The structure can also be modified to support more general semigroup range sum queries in O(logB N) memory transfers, using O(Nlog2 N) space for three-sided queries...... and O(Nlog22 N/log2log2 N) space for four-sided queries. Based on the O(Nlog N) space range counting structure, we develop a data structure that uses O(Nlog2 N) space and answers three-sided range queries in O(logB N+T/B) memory transfers, where T is the number of reported points. Based...

  8. Automatic counting of microglial cell activation and its applications

    Directory of Open Access Journals (Sweden)

    Beatriz I Gallego

    2016-01-01

    Full Text Available Glaucoma is a multifactorial optic neuropathy characterized by the damage and death of the retinal ganglion cells. This disease results in vision loss and blindness. Any vision loss resulting from the disease cannot be restored and nowadays there is no available cure for glaucoma; however an early detection and treatment, could offer neuronal protection and avoid later serious damages to the visual function. A full understanding of the etiology of the disease will still require the contribution of many scientific efforts. Glial activation has been observed in glaucoma, being microglial proliferation a hallmark in this neurodegenerative disease. A typical project studying these cellular changes involved in glaucoma often needs thousands of images - from several animals - covering different layers and regions of the retina. The gold standard to evaluate them is the manual count. This method requires a large amount of time from specialized personnel. It is a tedious process and prone to human error. We present here a new method to count microglial cells by using a computer algorithm. It counts in one hour the same number of images that a researcher counts in four weeks, with no loss of reliability.

  9. Eutectic cell and nodule count as the quality factors of cast iron

    Directory of Open Access Journals (Sweden)

    E. Fraś

    2008-10-01

    Full Text Available In this work the predictions based on a theoretical analysis aimed at elucidating of eutectic cell count or nodule counts N wereexperimentally verified. The experimental work was focused on processing flake graphite and ductile iron under various inoculationconditions in order to achieve various physicochemical states of the experimental melts. In addition, plates of various wall thicknesses, s were cast and the resultant eutectic cell or nodule counts were established. Moreover, thermal analysis was used to find out the degree of maximum undercooling for the graphite eutectic, Tm. A relationship was found between the eutectic cell or nodule count and the maximum undercooling Tm.. In addition it was also found that N can be related to the wall thickness of plate shaped castings. Finally, the present work provides a rational for the effect of technological factors such as the melt chemistry, inoculation practice, and holding temperature and time on the resultant cell count or nodule count of cast iron. In particular, good agreement was found between the predictions of the theoretical analysis and the experimental data.

  10. Counting problems for number rings

    NARCIS (Netherlands)

    Brakenhoff, Johannes Franciscus

    2009-01-01

    In this thesis we look at three counting problems connected to orders in number fields. First we study the probability that for a random polynomial f in Z[X] the ring Z[X]/f is the maximal order in Q[X]/f. Connected to this is the probability that a random polynomial has a squarefree

  11. Health Advocacy--Counting the Costs

    Science.gov (United States)

    Dyall, Lorna; Marama, Maria

    2010-01-01

    Access to, and delivery of, safe and culturally appropriate health services is increasingly important in New Zealand. This paper will focus on counting the costs of health advocacy through the experience of a small non government charitable organisation, the Health Advocates Trust, (HAT) which aimed to provide advocacy services for a wide range of…

  12. Concurrent non-deferred reference counting on the Microgrid: first experiences

    NARCIS (Netherlands)

    Herhut, S.; Joslin, C.; Scholz, S.-B.; Poss, R.; Grelck, C.

    2011-01-01

    We present a first evaluation of our novel approach for non- deferred reference counting on the Microgrid many-core architecture. Non-deferred reference counting is a fundamental building block of im- plicit heap management of functional array languages in general and Sin- gle Assignment C in

  13. How much do women count if they not counted?

    Directory of Open Access Journals (Sweden)

    Federica Taddia

    2006-01-01

    Full Text Available The condition of women throughout the world is marked by countless injustices and violations of the most fundamental rights established by the Universal Declaration of human rights and every culture is potentially prone to commit discrimination against women in various forms. Women are worse fed, more exposed to physical violence, more exposed to diseases and less educated; they have less access to, or are excluded from, vocational training paths; they are the most vulnerable among prisoners of conscience, refugees and immigrants and the least considered within ethnic minorities; from their very childhood, women are humiliated, undernourished, sold, raped and killed; their work is generally less paid compared to men’s work and in some countries they are victims of forced marriages. Such condition is the result of old traditions that implicit gender-differentiated education has long promoted through cultural models based on theories, practices and policies marked by discrimination and structured differentially for men and women. Within these cultural models, the basic educational institutions have played and still play a major role in perpetuating such traditions. Nevertheless, if we want to overcome inequalities and provide women with empowerment, we have to start right from the educational institutions and in particular from school, through the adoption of an intercultural approach to education: an approach based on active pedagogy and on methods of analysis, exchange and enhancement typical of socio-educational animation. The intercultural approach to education is attentive to promote the realisation of each individual and the dignity and right of everyone to express himself/herself in his/her own way. Such an approach will give women the opportunity to become actual agents of collective change and to get the strength and wellbeing necessary to count and be counted as human beings entitled to freedom and equality, and to have access to all

  14. Silicon Quantum Dots with Counted Antimony Donor Implants

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Meenakshi [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Center for Integrated Nanotechnologies; Pacheco, Jose L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Center for Integrated Nanotechnologies; Perry, Daniel Lee [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Center for Integrated Nanotechnologies; Garratt, E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Center for Integrated Nanotechnologies; Ten Eyck, Gregory A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Center for Integrated Nanotechnologies; Wendt, Joel R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Center for Integrated Nanotechnologies; Manginell, Ronald P. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Center for Integrated Nanotechnologies; Luhman, Dwight [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Center for Integrated Nanotechnologies; Bielejec, Edward S. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Center for Integrated Nanotechnologies; Lilly, Michael [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Center for Integrated Nanotechnologies; Carroll, Malcolm S. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Center for Integrated Nanotechnologies

    2015-10-01

    Deterministic control over the location and number of donors is crucial to donor spin quantum bits (qubits) in semiconductor based quantum computing. A focused ion beam is used to implant close to quantum dots. Ion detectors are integrated next to the quantum dots to sense the implants. The numbers of ions implanted can be counted to a precision of a single ion. Regular coulomb blockade is observed from the quantum dots. Charge offsets indicative of donor ionization, are observed in devices with counted implants.

  15. White Blood Cell Counts and Malaria

    National Research Council Canada - National Science Library

    McKenzie, F. E; Prudhomme, Wendy A; Magill, Alan J; Forney, J. R; Permpanich, Barnyen; Lucas, Carmen; Gasser, Jr., Robert A; Wongsrichanalai, Chansuda

    2005-01-01

    White blood cells (WBCs) were counted in 4697 individuals who presented to outpatient malaria clinics in Maesod, Tak Province, Thailand, and Iquitos, Peru, between 28 May and 28 August 1998 and between 17 May and 9 July 1999...

  16. Coincidence and noncoincidence counting (81Rb and 43K): a comparative study

    International Nuclear Information System (INIS)

    Ikeda, S.; Duken, H.; Tillmanns, H.; Bing, R.J.

    1975-01-01

    The accuracy of imaging and resolution obtained with 81 Rb and 43 K using coincidence and noncoincidence counting was compared. Phantoms and isolated infarcted dog hearts were used. The results clearly show the superiority of coincidence counting with a resolution of 0.5 cm. Noncoincidence counting failed to reveal even sizable defects in the radioactive source. (U.S.)

  17. HgCdTe APD-based linear-mode photon counting components and ladar receivers

    Science.gov (United States)

    Jack, Michael; Wehner, Justin; Edwards, John; Chapman, George; Hall, Donald N. B.; Jacobson, Shane M.

    2011-05-01

    Linear mode photon counting (LMPC) provides significant advantages in comparison with Geiger Mode (GM) Photon Counting including absence of after-pulsing, nanosecond pulse to pulse temporal resolution and robust operation in the present of high density obscurants or variable reflectivity objects. For this reason Raytheon has developed and previously reported on unique linear mode photon counting components and modules based on combining advanced APDs and advanced high gain circuits. By using HgCdTe APDs we enable Poisson number preserving photon counting. A metric of photon counting technology is dark count rate and detection probability. In this paper we report on a performance breakthrough resulting from improvement in design, process and readout operation enabling >10x reduction in dark counts rate to ~10,000 cps and >104x reduction in surface dark current enabling long 10 ms integration times. Our analysis of key dark current contributors suggest that substantial further reduction in DCR to ~ 1/sec or less can be achieved by optimizing wavelength, operating voltage and temperature.

  18. Analysis of dental caries using generalized linear and count regression models

    Directory of Open Access Journals (Sweden)

    Javali M. Phil

    2013-11-01

    Full Text Available Generalized linear models (GLM are generalization of linear regression models, which allow fitting regression models to response data in all the sciences especially medical and dental sciences that follow a general exponential family. These are flexible and widely used class of such models that can accommodate response variables. Count data are frequently characterized by overdispersion and excess zeros. Zero-inflated count models provide a parsimonious yet powerful way to model this type of situation. Such models assume that the data are a mixture of two separate data generation processes: one generates only zeros, and the other is either a Poisson or a negative binomial data-generating process. Zero inflated count regression models such as the zero-inflated Poisson (ZIP, zero-inflated negative binomial (ZINB regression models have been used to handle dental caries count data with many zeros. We present an evaluation framework to the suitability of applying the GLM, Poisson, NB, ZIP and ZINB to dental caries data set where the count data may exhibit evidence of many zeros and over-dispersion. Estimation of the model parameters using the method of maximum likelihood is provided. Based on the Vuong test statistic and the goodness of fit measure for dental caries data, the NB and ZINB regression models perform better than other count regression models.

  19. Changes in total and differential white cell counts, total lymphocyte ...

    African Journals Online (AJOL)

    Background: Published reports on the possible changes in the various immune cell populations, especially the total lymphocyte and CD4 cell counts, during the menstrual cycle in Nigerian female subjects are relatively scarce. Aim: To determine possible changes in the total and differential white blood cell [WBC] counts, ...

  20. Liquid scintillation, counting, and compositions

    International Nuclear Information System (INIS)

    Sena, E.A.; Tolbert, B.M.; Sutula, C.L.

    1975-01-01

    The emissions of radioactive isotopes in both aqueous and organic samples can be measured by liquid scintillation counting in micellar systems. The micellar systems are made up of scintillation solvent, scintillation solute and a mixture of surfactants, preferably at least one of which is relatively oil-soluble water-insoluble and another which is relatively water-soluble oil-insoluble

  1. Hybrid statistics-simulations based method for atom-counting from ADF STEM images

    Energy Technology Data Exchange (ETDEWEB)

    De wael, Annelies, E-mail: annelies.dewael@uantwerpen.be [Electron Microscopy for Materials Science (EMAT), University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp (Belgium); De Backer, Annick [Electron Microscopy for Materials Science (EMAT), University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp (Belgium); Jones, Lewys; Nellist, Peter D. [Department of Materials, University of Oxford, Parks Road, OX1 3PH Oxford (United Kingdom); Van Aert, Sandra, E-mail: sandra.vanaert@uantwerpen.be [Electron Microscopy for Materials Science (EMAT), University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp (Belgium)

    2017-06-15

    A hybrid statistics-simulations based method for atom-counting from annular dark field scanning transmission electron microscopy (ADF STEM) images of monotype crystalline nanostructures is presented. Different atom-counting methods already exist for model-like systems. However, the increasing relevance of radiation damage in the study of nanostructures demands a method that allows atom-counting from low dose images with a low signal-to-noise ratio. Therefore, the hybrid method directly includes prior knowledge from image simulations into the existing statistics-based method for atom-counting, and accounts in this manner for possible discrepancies between actual and simulated experimental conditions. It is shown by means of simulations and experiments that this hybrid method outperforms the statistics-based method, especially for low electron doses and small nanoparticles. The analysis of a simulated low dose image of a small nanoparticle suggests that this method allows for far more reliable quantitative analysis of beam-sensitive materials. - Highlights: • A hybrid method for atom-counting from ADF STEM images is introduced. • Image simulations are incorporated into a statistical framework in a reliable manner. • Limits of the existing methods for atom-counting are far exceeded. • Reliable counting results from an experimental low dose image are obtained. • Progress towards reliable quantitative analysis of beam-sensitive materials is made.

  2. Deep 3 GHz number counts from a P(D) fluctuation analysis

    Science.gov (United States)

    Vernstrom, T.; Scott, Douglas; Wall, J. V.; Condon, J. J.; Cotton, W. D.; Fomalont, E. B.; Kellermann, K. I.; Miller, N.; Perley, R. A.

    2014-05-01

    Radio source counts constrain galaxy populations and evolution, as well as the global star formation history. However, there is considerable disagreement among the published 1.4-GHz source counts below 100 μJy. Here, we present a statistical method for estimating the μJy and even sub-μJy source count using new deep wide-band 3-GHz data in the Lockman Hole from the Karl G. Jansky Very Large Array. We analysed the confusion amplitude distribution P(D), which provides a fresh approach in the form of a more robust model, with a comprehensive error analysis. We tested this method on a large-scale simulation, incorporating clustering and finite source sizes. We discuss in detail our statistical methods for fitting using Markov chain Monte Carlo, handling correlations, and systematic errors from the use of wide-band radio interferometric data. We demonstrated that the source count can be constrained down to 50 nJy, a factor of 20 below the rms confusion. We found the differential source count near 10 μJy to have a slope of -1.7, decreasing to about -1.4 at fainter flux densities. At 3 GHz, the rms confusion in an 8-arcsec full width at half-maximum beam is ˜ 1.2 μJy beam-1, and a radio background temperature ˜14 mK. Our counts are broadly consistent with published evolutionary models. With these results, we were also able to constrain the peak of the Euclidean normalized differential source count of any possible new radio populations that would contribute to the cosmic radio background down to 50 nJy.

  3. Standardization of Ga-68 by coincidence measurements, liquid scintillation counting and 4πγ counting

    International Nuclear Information System (INIS)

    Roteta, Miguel; Peyres, Virginia; Rodríguez Barquero, Leonor; García-Toraño, Eduardo; Arenillas, Pablo; Balpardo, Christian; Rodrígues, Darío; Llovera, Roberto

    2012-01-01

    The radionuclide 68 Ga is one of the few positron emitters that can be prepared in-house without the use of a cyclotron. It disintegrates to the ground state of 68 Zn partially by positron emission (89.1%) with a maximum energy of 1899.1 keV, and partially by electron capture (10.9%). This nuclide has been standardized in the frame of a cooperation project between the Radionuclide Metrology laboratories from CIEMAT (Spain) and CNEA (Argentina). Measurements involved several techniques: 4πβ−γ coincidences, integral gamma counting and Liquid Scintillation Counting using the triple to double coincidence ratio and the CIEMAT/NIST methods. Given the short half-life of the radionuclide assayed, a direct comparison between results from both laboratories was excluded and a comparison of experimental efficiencies of similar NaI detectors was used instead. - Highlights: ► We standardized the positron emitter Ga-68 in a bilateral cooperation. ► We used several techniques, as coincidence, integral gamma and liquid scintillation. ► An efficiency comparison replaced a direct comparison of reference materials.

  4. Red Blood Cell Count Automation Using Microscopic Hyperspectral Imaging Technology.

    Science.gov (United States)

    Li, Qingli; Zhou, Mei; Liu, Hongying; Wang, Yiting; Guo, Fangmin

    2015-12-01

    Red blood cell counts have been proven to be one of the most frequently performed blood tests and are valuable for early diagnosis of some diseases. This paper describes an automated red blood cell counting method based on microscopic hyperspectral imaging technology. Unlike the light microscopy-based red blood count methods, a combined spatial and spectral algorithm is proposed to identify red blood cells by integrating active contour models and automated two-dimensional k-means with spectral angle mapper algorithm. Experimental results show that the proposed algorithm has better performance than spatial based algorithm because the new algorithm can jointly use the spatial and spectral information of blood cells.

  5. Characteristics of commercially available well scintillation counting systems

    International Nuclear Information System (INIS)

    Morris, A.C. Jr.; Dudley, R.A.

    1977-01-01

    The document contains data on commercially available well scintillation counting systems as collected during early 1977, and up-dated in July 1977, by the staff of the Medical Application Section, Division of Life Sciences, IAEA. These data also appear as Appendix 2 of IAEA-201, Well Scintillation Counting Systems for Nuclear Medicine Applications in Developing Countries, Vienna, 1977. An attempt was made to include instruments currently offered by all manufacturers. However, it is inevitable that several manufacturers remain unknown to the Section, and a number of known manufacturers failed to provide adequate information. (orig.) [de

  6. 20 CFR 418.3405 - What types of resources do we count?

    Science.gov (United States)

    2010-04-01

    ... of resources that are ordinarily liquid are stocks, bonds, mutual fund shares, promissory notes... workdays, we will not count it as a resource. (b) We count the equity value of real property as a resource...

  7. Is automated platelet counting still a problem in thrombocytopenic blood?

    Directory of Open Access Journals (Sweden)

    Raimundo Antônio Gomes Oliveira

    Full Text Available CONTEXT: Reliable platelet counting is crucial for indicating prophylactic platelet transfusion in thrombocytopenic patients. OBJECTIVE: To evaluate the precision and accuracy of platelet counting for thrombocytopenic patients, using four different automated counters in comparison with the Brecher & Cronkite reference method recommended by the International Committee for Standardization in Hematology (ICSH. TYPE OF STUDY: Automated platelet counting assessment in thrombocytopenic patients. SETTING: Hematology Laboratory, Hospital do Servidor Público Estadual de São Paulo, and the Hematology Division of Instituto Adolfo Lutz, São Paulo, SP, Brazil. MAIN MEASUREMENTS: Brecher & Cronkite reference method and four different automated platelet counters. PARTICIPANTS: 43 thrombocytopenic patients with platelet counts of less than 30,000/µl RESULTS: The ADVIA-120 (Bayer, Coulter STKS, H1 System (Technicom-Bayer and Coulter T-890 automatic instruments presented great precision and accuracy in relation to laboratory thrombocytopenic samples obtained by diluting blood from normal donors. However, when thrombocytopenic patients were investigated, all the counters except ADVIA (which is based on volume and refraction index showed low accuracy when compared to the Brecher & Cronkite reference method (ICSH. The ADVIA counter showed high correlation (r = 0.947. However, all counters showed flags in thrombocytopenic samples. CONCLUSION: The Brecher & Cronkite reference method should always be indicated in thrombocytopenic patients for platelet counts below 30,000 plt /µl obtained in one dimensional counters.

  8. Reproducibility of Manual Platelet Estimation Following Automated Low Platelet Counts

    Directory of Open Access Journals (Sweden)

    Zainab S Al-Hosni

    2016-11-01

    Full Text Available Objectives: Manual platelet estimation is one of the methods used when automated platelet estimates are very low. However, the reproducibility of manual platelet estimation has not been adequately studied. We sought to assess the reproducibility of manual platelet estimation following automated low platelet counts and to evaluate the impact of the level of experience of the person counting on the reproducibility of manual platelet estimates. Methods: In this cross-sectional study, peripheral blood films of patients with platelet counts less than 100 × 109/L were retrieved and given to four raters to perform manual platelet estimation independently using a predefined method (average of platelet counts in 10 fields using 100× objective multiplied by 20. Data were analyzed using intraclass correlation coefficient (ICC as a method of reproducibility assessment. Results: The ICC across the four raters was 0.840, indicating excellent agreement. The median difference of the two most experienced raters was 0 (range: -64 to 78. The level of platelet estimate by the least-experienced rater predicted the disagreement (p = 0.037. When assessing the difference between pairs of raters, there was no significant difference in the ICC (p = 0.420. Conclusions: The agreement between different raters using manual platelet estimation was excellent. Further confirmation is necessary, with a prospective study using a gold standard method of platelet counts.

  9. Poisson and negative binomial item count techniques for surveys with sensitive question.

    Science.gov (United States)

    Tian, Guo-Liang; Tang, Man-Lai; Wu, Qin; Liu, Yin

    2017-04-01

    Although the item count technique is useful in surveys with sensitive questions, privacy of those respondents who possess the sensitive characteristic of interest may not be well protected due to a defect in its original design. In this article, we propose two new survey designs (namely the Poisson item count technique and negative binomial item count technique) which replace several independent Bernoulli random variables required by the original item count technique with a single Poisson or negative binomial random variable, respectively. The proposed models not only provide closed form variance estimate and confidence interval within [0, 1] for the sensitive proportion, but also simplify the survey design of the original item count technique. Most importantly, the new designs do not leak respondents' privacy. Empirical results show that the proposed techniques perform satisfactorily in the sense that it yields accurate parameter estimate and confidence interval.

  10. Research about an automatic timing count system based on LabView

    International Nuclear Information System (INIS)

    Yan Jie; Liu Rong; Jian Li; Lu Xinxin; Zhu Tonghua; Wang Mei; Wen Zhongwei; Lin Jufang; Li Cheng

    2009-01-01

    Based on the LabView Virtual Instrument Development Platform and the GPIB instrument control and data transmission bus protocol, the design and research of a virtual instrument about an automatic timing count system using ORTEC 974 Counter/Timer is introduced in this paper. Comparing with the real instrument, the virtual instrument system enriched the timing count function and carried out the remote control of the real instrument. The counts and measured time can be recorded automatically during the measurement process for the further analysis and processing. (authors)

  11. Making fingers and words count in a cognitive robot

    Directory of Open Access Journals (Sweden)

    Vivian Milagros De La Cruz

    2014-02-01

    Full Text Available Evidence from developmental as well as neuroscientific studies suggest that finger counting activity plays an important role in the acquisition of numerical skills in children. It has been claimed that this skill helps in building motor-based representations of number that continue to influence number processing well into adulthood, facilitating the emergence of number concepts from sensorimotor experience through a bottom-up process. The act of counting also involves the acquisition and use of a verbal number system of which number words are the basic building blocks. Using a Cognitive Developmental Robotics paradigm we present results of a modeling experiment on whether finger counting and the association of number words (or tags to fingers, could serve to bootstrap the representation of number in a cognitive robot, enabling it to perform basic numerical operations such as addition. The cognitive architecture of the robot is based on artificial neural networks, which enable the robot to learn both sensorimotor skills (finger counting and linguistic skills (using number words. The results obtained in our experiments show that learning the number words in sequence along with finger configurations helps the fast building of the initial representation of number in the robot. Number knowledge, is instead, not as efficiently developed when number words are learned out of sequence without finger counting. Furthermore, the internal representations of the finger configurations themselves, developed by the robot as a result of the experiments, sustain the execution of basic arithmetic operations, something consistent with evidence coming from developmental research with children. The model and experiments demonstrate the importance of sensorimotor skill learning in robots for the acquisition of abstract knowledge such as numbers.

  12. Data analysis in emission tomography using emission-count posteriors

    International Nuclear Information System (INIS)

    Sitek, Arkadiusz

    2012-01-01

    A novel approach to the analysis of emission tomography data using the posterior probability of the number of emissions per voxel (emission count) conditioned on acquired tomographic data is explored. The posterior is derived from the prior and the Poisson likelihood of the emission-count data by marginalizing voxel activities. Based on emission-count posteriors, examples of Bayesian analysis including estimation and classification tasks in emission tomography are provided. The application of the method to computer simulations of 2D tomography is demonstrated. In particular, the minimum-mean-square-error point estimator of the emission count is demonstrated. The process of finding this estimator can be considered as a tomographic image reconstruction technique since the estimates of the number of emissions per voxel divided by voxel sensitivities and acquisition time are the estimates of the voxel activities. As an example of a classification task, a hypothesis stating that some region of interest (ROI) emitted at least or at most r-times the number of events in some other ROI is tested. The ROIs are specified by the user. The analysis described in this work provides new quantitative statistical measures that can be used in decision making in diagnostic imaging using emission tomography. (paper)

  13. Data analysis in emission tomography using emission-count posteriors

    Science.gov (United States)

    Sitek, Arkadiusz

    2012-11-01

    A novel approach to the analysis of emission tomography data using the posterior probability of the number of emissions per voxel (emission count) conditioned on acquired tomographic data is explored. The posterior is derived from the prior and the Poisson likelihood of the emission-count data by marginalizing voxel activities. Based on emission-count posteriors, examples of Bayesian analysis including estimation and classification tasks in emission tomography are provided. The application of the method to computer simulations of 2D tomography is demonstrated. In particular, the minimum-mean-square-error point estimator of the emission count is demonstrated. The process of finding this estimator can be considered as a tomographic image reconstruction technique since the estimates of the number of emissions per voxel divided by voxel sensitivities and acquisition time are the estimates of the voxel activities. As an example of a classification task, a hypothesis stating that some region of interest (ROI) emitted at least or at most r-times the number of events in some other ROI is tested. The ROIs are specified by the user. The analysis described in this work provides new quantitative statistical measures that can be used in decision making in diagnostic imaging using emission tomography.

  14. Radon Daughters Background Reduction in Alpha Particles Counting System

    International Nuclear Information System (INIS)

    Dadon, S. S.; Pelled, O.; Orion, I.

    2014-01-01

    The ABPC method is using a serially occurring events of the beta decay of the 214Bi fallow by alpha decay of the 214Po that take place almost simultaneously to detect the Pseudo Coincidence Event (PCE) from the RDP, and to subtract them from the gross alpha counts. 267 This work showed that it is possible to improve the efficiency of RDP background reduction, including subtracting the 218Po contribution by using the ABPC method based on a single solid state silicon PIPS detector. False counts percentage obtained at the output of the PCE circuit were smaller than 0.1%. The results show that the PCE circuit was not influenced by non RDP alpha emitters. The PCE system did not reduce the non PCE of the 218Po. After 20 minutes the 218Po was strongly decayed, and its contribution became negligible. In order to overcome this disadvantage, a mathematical matching calculations for the 214Po and the 218Po decay equations were employed, and a constant ratio of the APo214(0) / APo218(0) was obtained. This ratio can be used to estimate the count rate of the 218Po at the first 20 minutes, and to subtract it from the total count rate in order to obtain correct RDP reduction

  15. Double hard scattering without double counting

    Energy Technology Data Exchange (ETDEWEB)

    Diehl, Markus [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Gaunt, Jonathan R. [VU Univ. Amsterdam (Netherlands). NIKHEF Theory Group; Schoenwald, Kay [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany)

    2017-02-15

    Double parton scattering in proton-proton collisions includes kinematic regions in which two partons inside a proton originate from the perturbative splitting of a single parton. This leads to a double counting problem between single and double hard scattering. We present a solution to this problem, which allows for the definition of double parton distributions as operator matrix elements in a proton, and which can be used at higher orders in perturbation theory. We show how the evaluation of double hard scattering in this framework can provide a rough estimate for the size of the higher-order contributions to single hard scattering that are affected by double counting. In a numeric study, we identify situations in which these higher-order contributions must be explicitly calculated and included if one wants to attain an accuracy at which double hard scattering becomes relevant, and other situations where such contributions may be neglected.

  16. Going Online to Make Learning Count

    Directory of Open Access Journals (Sweden)

    Cathy Brigham

    2011-01-01

    Full Text Available Adult students often come to higher education with college-level learning that they have acquired outside of the classroom – from the workplace, military service, self-study, or hobbies. For decades, many forward-thinking colleges and universities have been offering services to evaluate that learning and award it college credit that counts towards a degree. However, for a range of reasons, not every institution can offer prior learning assessment (PLA in every discipline or for every student. With funding from several U.S. philanthropic organizations, the Council for Adult and Experiential Learning (CAEL is launching Learning Counts, a national online service that will offer students a range of opportunities to have their learning evaluated for college credit. This online service will expand the capacity of institutions offering PLA to students and provide an efficient and scalable delivery mechanism for the awarding of credit through PLA.

  17. Double hard scattering without double counting

    International Nuclear Information System (INIS)

    Diehl, Markus; Gaunt, Jonathan R.

    2017-02-01

    Double parton scattering in proton-proton collisions includes kinematic regions in which two partons inside a proton originate from the perturbative splitting of a single parton. This leads to a double counting problem between single and double hard scattering. We present a solution to this problem, which allows for the definition of double parton distributions as operator matrix elements in a proton, and which can be used at higher orders in perturbation theory. We show how the evaluation of double hard scattering in this framework can provide a rough estimate for the size of the higher-order contributions to single hard scattering that are affected by double counting. In a numeric study, we identify situations in which these higher-order contributions must be explicitly calculated and included if one wants to attain an accuracy at which double hard scattering becomes relevant, and other situations where such contributions may be neglected.

  18. Single ion counting with a MCP (microchannel plate) detector

    Energy Technology Data Exchange (ETDEWEB)

    Tawara, Hiroko; Sasaki, Shinichi; Miyajima, Mitsuhiro [National Lab. for High Energy Physics, Tsukuba, Ibaraki (Japan); Shibamura, Eido

    1996-07-01

    In this study, a single-ion-counting method using alpha-particle-impact ionization of Ar atoms is demonstrated and the preliminary {epsilon}{sub mcp} for Ar ions with incident energies of 3 to 4.7 keV is determined. The single-ion counting by the MCP is aimed to be performed under experimental conditions as follows: (1) A signal from the MCP is reasonably identified as incidence of single Ar-ion. (2) The counting rate of Ar ions is less than 1 s{sup -1}. (3) The incident Ar ions are not focused on a small part of an active area of the MCP, namely, {epsilon}{sub mcp} is determined with respect to the whole active area of the MCP. So far, any absolute detection efficiency has not been reported under these conditions. (J.P.N.)

  19. Device for treating plastic counting vials containing radioactive liquids

    International Nuclear Information System (INIS)

    Neidhart, B.; Brindoepke, H.W.; Flocke, W.; Kringe, K.P.; Lippmann, C.H.

    1985-01-01

    The treatment consists of separating the radioactive contents of the counting vial from its plastic components. The apparatus consists of a device for continuously supplying the counting vials to be treated, a means for crushing the vials into chips of plastic and a facility by means of which the radioactive contents of the counting vial and the separated plastic chips are collected separately from one another. A stirring assembly with a motor-driven stirrer and an alignment device are also provided. The radioactive substances pass through a sieve while the plastic chips slide down the sieve chute and into another container. All the metal parts of the facility are of stainless steel. The plastic chips collected in the sieve holder are washed and, after drying, are removed as negligibly radioactive solids. The weakly radioactive wash liquid is separated and collected. (orig./PW)

  20. Lower white blood cell counts in elite athletes training for highly aerobic sports.

    Science.gov (United States)

    Horn, P L; Pyne, D B; Hopkins, W G; Barnes, C J

    2010-11-01

    White cell counts at rest might be lower in athletes participating in selected endurance-type sports. Here, we analysed blood tests of elite athletes collected over a 10-year period. Reference ranges were established for 14 female and 14 male sports involving 3,679 samples from 937 females and 4,654 samples from 1,310 males. Total white blood cell counts and counts of neutrophils, lymphocytes and monocytes were quantified. Each sport was scaled (1-5) for its perceived metabolic stress (aerobic-anaerobic) and mechanical stress (concentric-eccentric) by 13 sports physiologists. Substantially lower total white cell and neutrophil counts were observed in aerobic sports of cycling and triathlon (~16% of test results below the normal reference range) compared with team or skill-based sports such as water polo, cricket and volleyball. Mechanical stress of sports had less effect on the distribution of cell counts. The lower white cell counts in athletes in aerobic sports probably represent an adaptive response, not underlying pathology.

  1. Relationship of blood and milk cell counts with mastitic pathogens in Murrah buffaloes

    Directory of Open Access Journals (Sweden)

    C. Singh

    2010-02-01

    Full Text Available The present study was undertaken to see the effect of mastitic pathogens on the blood and milk counts of Murrah buffaloes. Milk and blood samples were collected from 9 mastitic Murrah buffaloes. The total leucocyte Counts (TLC and Differential leucocyte counts (DLC in blood were within normal range and there was a non-significant change in blood counts irrespective of different mastitic pathogens. Normal milk quarter samples had significantly (P<0.01 less Somatic cell counts (SCC. Lymphocytes were significantly higher in normal milk samples, whereas infected samples had a significant increase (P<0.01 in milk neutrophils. S. aureus infected buffaloes had maximum milk SCC, followed by E. coli and S. agalactiae. Influx of neutrophils in the buffalo mammary gland was maximum for S. agalactiae, followed by E.cli and S. aureus. The study indicated that level of mastitis had no affect on blood counts but it influenced the milk SCC of normal quarters.

  2. Counting a Culture of Mealworms

    Science.gov (United States)

    Ashbrook, Peggy

    2007-01-01

    Math is not the only topic that will be discussed when young children are asked to care for and count "mealworms," a type of insect larvae (just as caterpillars are the babies of butterflies, these larvae are babies of beetles). The following activity can take place over two months as the beetles undergo metamorphosis from larvae to adults. As the…

  3. On Counting the Rational Numbers

    Science.gov (United States)

    Almada, Carlos

    2010-01-01

    In this study, we show how to construct a function from the set N of natural numbers that explicitly counts the set Q[superscript +] of all positive rational numbers using a very intuitive approach. The function has the appeal of Cantor's function and it has the advantage that any high school student can understand the main idea at a glance…

  4. The Fallacy of Word-Counts.

    Science.gov (United States)

    Engels, L.K.

    1968-01-01

    The greatest fallacy of word counts, the author maintains, lies in the fact that advocates of frequency lists stress the high percentage without telling the whole truth. It has become common to pretend that a frequency list of 3,000 words covers 95 percent of the language, that it enables a person to speak and understand a foreign language by…

  5. Somatic cell counts in bulk milk and their importance for milk processing

    Science.gov (United States)

    Savić, N. R.; Mikulec, D. P.; Radovanović, R. S.

    2017-09-01

    Bulk tank milk somatic cell counts are the indicator of the mammary gland health in the dairy herds and may be regarded as an indirect measure of milk quality. Elevated somatic cell counts are correlated with changes in milk composition The aim of this study was to assess the somatic cell counts that significantly affect the quality of milk and dairy products. We examined the somatic cell counts in bulk tank milk samples from 38 farms during the period of 6 months, from December to the May of the next year. The flow cytometry, Fossomatic was used for determination of somatic cell counts. In the same samples content of total proteins and lactose was determined by Milcoscan. Our results showed that average values for bulk tank milk samples were 273,605/ml from morning milking and 292,895/ml from evening milking. The average values for total proteins content from morning and evening milking are 3,31 and 3,34%, respectively. The average values for lactose content from morning and evening milking are 4,56 and 4,63%, respectively. The highest somatic cell count (516,000/ml) was detected in bulk tank milk sample from evening milk in the Winter and the lowest content of lactose was 4,46%. Our results showed that obtained values for bulk tank milk somatic cell counts did not significantly affected the content of total proteins and lactose.

  6. Evaluation for asbestos exposure in lung cancer surgery cases. Relationships between asbestos body count and pleural plaques and between asbestos body count and pulmonary fibrosis

    International Nuclear Information System (INIS)

    Yusa, Toshikazu; Yasukawa, Tomohisa; Shioda, Hironobu; Hirai, Fumiko; Hiroshima, Kenzo; Kishimoto, Takumi

    2011-01-01

    This study was designed to examine the significance of pleural plaques and pulmonary fibrosis in the evaluation of asbestos exposure level. The subjects were patients who had undergone surgery for lung cancer. There were 64 patients who had pleural plaques based on surgical findings (pleural plaque group) and 9 patients who had neither a history of asbestos exposure nor pleural plaque (control group). An examination was performed regarding the extent of pleural plaques and the presence or absence of pulmonary fibrosis. The relationships between these findings and the asbestos body count in the resected lung were investigated. If chest CT showed no pleural plaque, the case was classified as class 0. If chest CT showed pleural plaques, the CT slice with the most extensive pleural plaque in either side was selected. If the plaque extended to less than one quarter of the inner chest wall, the case was classified as class 1. If the extent was one quarter or more, the case was classified as class 2. The cases were considered to have pulmonary fibrosis if the fibrotic findings were equivalent to those of asbestosis of type 1 or more by chest X-ray photography (XP) and if fibrosis was observed in CT. All other cases were considered not to have pulmonary fibrosis. The median asbestos body counts were 1,018 bodies per gram of dried lung in the pleural plaque group and 263 per gram of dried lung in the control group. There was a statistically significant difference between these groups (p=0.0034). There were 25 patients with class 0 pleural plaque, 17 patients with class 1, and 22 patients with class 2. Their median asbestos body counts were 612, 439, and 5,626 bodies, respectively. All class 0 or 1 patients had an asbestos body count of less than 5,000 bodies. There was no significant difference in the counts between patients with class 0 and 1. All class 2 patients had an asbestos body count of 1,000 bodies or more. The count of class 2 patients was significantly higher

  7. Age determination in manatees using growth-layer-group counts in bone

    Science.gov (United States)

    Marmontel, M.; O'Shea, T.J.; Kochman, H.I.; Humphrey, S.R.

    1996-01-01

    Growth layers were observed in histological preparations of bones of known-age, known minimum-age, and tetracycline-marked free-ranging and captive Florida manatees (Trichechus manatus latirostris), substantiating earlier preliminary findings of other studies. Detailed analysis of 17 new case histories showed that growth-layer group (GLG) counts in the periotic bone were consistent with known age, or time since tetracycline administration, but were less reliable in other bones. GLG counts were also made in periotic bones of 1,196 Florida manatees of unknown age found dead from 1974 through 1991. These counts were conducted in order to assess variability and to determine relationships among estimated age, size, sex, and degree of bone resorption. Resorption can interfere with accuracy of GLG counts. This effect does not occur until ages greater than about 15 yr and body lengths greater than 300 cm are attained. GLGs were also observed in periotic bones of Antillean manatees (Trichechus manatus manatus) but were not validated against known-age specimens. Use of GLG counts in the periotic bone is suitable for application to studies of population dynamics and other age-related aspects of manatee biology.

  8. Three-dimensional passive sensing photon counting for object classification

    Science.gov (United States)

    Yeom, Seokwon; Javidi, Bahram; Watson, Edward

    2007-04-01

    In this keynote address, we address three-dimensional (3D) distortion-tolerant object recognition using photon-counting integral imaging (II). A photon-counting linear discriminant analysis (LDA) is discussed for classification of photon-limited images. We develop a compact distortion-tolerant recognition system based on the multiple-perspective imaging of II. Experimental and simulation results have shown that a low level of photons is sufficient to classify out-of-plane rotated objects.

  9. Characterization of a new computer-ready photon counting system

    Science.gov (United States)

    Andor, Gyorgy

    1998-08-01

    The photon-counting system seems to be the best solution for extremely low optical power measurements. The Hamamatsu HC135 photon counting module has a built-in high-voltage power supply amplifier, discriminator, micro-controller with an RS232 serial output. It requires only a +5V supply voltage and an IBM PC or compatible computer to run. The system is supplied with an application software. This talk is about the testing of the device.

  10. Evaluation of Deterministic and Stochastic Components of Traffic Counts

    Directory of Open Access Journals (Sweden)

    Ivan Bošnjak

    2012-10-01

    Full Text Available Traffic counts or statistical evidence of the traffic processare often a characteristic of time-series data. In this paper fundamentalproblem of estimating deterministic and stochasticcomponents of a traffic process are considered, in the context of"generalised traffic modelling". Different methods for identificationand/or elimination of the trend and seasonal componentsare applied for concrete traffic counts. Further investigationsand applications of ARIMA models, Hilbert space formulationsand state-space representations are suggested.

  11. Automatic, time-interval traffic counts for recreation area management planning

    Science.gov (United States)

    D. L. Erickson; C. J. Liu; H. K. Cordell

    1980-01-01

    Automatic, time-interval recorders were used to count directional vehicular traffic on a multiple entry/exit road network in the Red River Gorge Geological Area, Daniel Boone National Forest. Hourly counts of entering and exiting traffic differed according to recorder location, but an aggregated distribution showed a delayed peak in exiting traffic thought to be...

  12. Counting efficiency formulae for two, three or four photomultiplier systems

    International Nuclear Information System (INIS)

    Grau Malonda, A.

    1993-01-01

    Counting efficiency formulae as a function of the non-detection probability and the electron distributions for systems with two, three or dour photomultipliers are obtained in this paper. It is assumed that the photocathode electron emission follows the Poisson distribution. The obtained formulae are basic to compute the counting efficiency in liquid scintillation spectrometers

  13. Pregnancies with Platelet Count Lower Than 70000 Platelets/μl

    Directory of Open Access Journals (Sweden)

    Semih Mun

    2006-08-01

    CONCLUSION: If thrombocyte count of a pregnant is not less than 70000/μl and her symptoms are not related with thrombocytopenia then only follow up for platelet counts is sufficient in pregnancy. However if it is less than 70000/μl, treatment of thrombocytopenia and strict follow up of patient is necessary.

  14. The Money/Counting Kit. The Prospectus Series, Paper No. 6.

    Science.gov (United States)

    Musumeci, Judith

    The Money/Counting Kit for Handicapped Children and Youth, frees the teacher from lessons in money and counting concepts and enables a student to learn at his own rate with immediate feedback from activity cards, name cards, thermoformed coin cards (optional), and self-instructional booklets. The activity cards, which may be used individually or…

  15. Baseline CD4 lymphocyte count among HIV patients in Kano ...

    African Journals Online (AJOL)

    kemrilib

    macrophages), the devastating effect of HIV on the immune system is not surprising. Given that HIV induced immunodeficiency is largely due to infection and gradual depletion of. CD4+ T-helper cells, CD4 count has become a useful indicator of immune function in infected patients. Hence CD4 count along with viral load ...

  16. Evaluating call-count procedures for measuring local mourning dove populations

    Science.gov (United States)

    Armbruster, M.J.; Baskett, T.S.; Goforth, W.R.; Sadler, K.C.

    1978-01-01

    Seventy-nine mourning dove call-count runs were made on a 32-km route in Osage County, Missouri, May 1-August 31, 1971 and 1972. Circular study areas, each 61 ha, surrounding stop numbers 4 and 5, were delineated for intensive nest searches and population estimates. Tallies of cooing male doves along the entire call-count route were quite variable in repeated runs, fluctuating as much as 50 percent on consecutive days. There were no consistent relationships between numbers of cooing males tallied at stops 4 and 5 and the numbers of current nests or doves estimated to be present in the surrounding study areas. We doubt the suitability of call-count procedures to estimate precisely the densities of breeding pairs, nests or production of doves on small areas. Our findings do not dispute the usefulness of the national call-count survey as an index to relative densities of mourning doves during the breeding season over large portions of the United States, or as an index to annual population trends.

  17. Re-Visiting the Competence/Performance Debate in the Acquisition of the Counting Principles

    Science.gov (United States)

    Le Corre, Mathieu; Van de Walle, Gretchen; Brannon, Elizabeth M.; Carey, Susan.

    2006-01-01

    Advocates of the ''continuity hypothesis'' have argued that innate non-verbal counting principles guide the acquisition of the verbal count list (Gelman & Gallistel, 1978). Some studies have supported this hypothesis, but others have suggested that the counting principles must be constructed anew by each child. Defenders of the continuity…

  18. Accurate disintegration-rate measurement of 55Fe by liquid scintillation counting

    International Nuclear Information System (INIS)

    Steyn, J.; Oberholzer, P.; Botha, S.M.

    1979-01-01

    A method involving liquid scintillation counting is described for the accurate measurement of disintegration rate of 55 Fe. The method is based on the use of calculated efficiency functions together with either of the nuclides 54 Mn and 51 Cr as internal standards for measurement of counting efficiencies by coincidence counting. The method was used by the NAC during a recent international intercomparison of radioactivity measurements, and a summary of the results obtained by nine participating laboratories is presented. A spread in results of several percent is evident [af

  19. Investigation of internal conversion electron lines by track counting technique

    CERN Document Server

    Islamov, T A; Kambarova, N T; Muminov, T M; Lebedev, N A; Solnyshkin, A A; Aleshin, Yu D; Kolesnikov, V V; Silaev, V I; Niipf-Tashgu, T

    2001-01-01

    The methodology of counting the tracks of the internal conversion electron (ICE) in the nuclear photoemulsion is described. The results on counting the ICE tracks on the photoplates for sup 1 sup 6 sup 1 Ho, sup 1 sup 6 sup 3 Tm, sup 1 sup 6 sup 6 Tm, sup 1 sup 3 sup 5 Ce is described. The above results are obtained through the MBI-9 microscope and the MAS-1 automated facility. The ICE track counting on the photoplates provides for essentially higher sensitivity as compared to the photometry method. This makes it possible to carry out measurements with the sources by 1000 times weaker as by the study into the density of blackening

  20. Factor V Leiden is associated with increased sperm count.

    Science.gov (United States)

    van Mens, T E; Joensen, U N; Bochdanovits, Z; Takizawa, A; Peter, J; Jørgensen, N; Szecsi, P B; Meijers, J C M; Weiler, H; Rajpert-De Meyts, E; Repping, S; Middeldorp, S

    2017-11-01

    Is the thrombophilia mutation factor V Leiden (FVL) associated with an increased total sperm count? Carriers of FVL have a higher total sperm count than non-FVL-carriers, which could not be explained by genetic linkage or by observations in a FVL-mouse model. FVL has a high prevalence in Caucasians despite detrimental health effects. Carriers have been shown to have higher fecundity, which might partly explain this evolutionary paradox. We determined FVL status in two cohorts (Dutch, n = 627; Danish, n = 854) of consecutively included men without known causes for spermatogenic failure, and performed an individual patient data meta-analysis of these two cohorts together with one previously published (Dutch, n = 908) cohort. We explored possible biological underpinnings for the relation between sperm count and FVL, by use of a FVL-mouse model and investigations of genetic linkage. Participants were male partners of subfertile couples (two Dutch cohorts) and young men from the general population (Danish cohort): FVL carrier rate was 4.0%, 4.6% and 7.3%, respectively. There were differences in smoking, abstinence time and age between the cohorts. We corrected for these in the primary analysis, which consisted of a mixed linear effects model, also incorporating unobjectified population differences. In public haplotype data from subjects of European descent, we explored linkage disequilibrium of FVL with all known single nucleotide polymorphisms in a 1.5 MB region around the F5 gene with an R2 cutoff of 0.8. We sequenced exons of four candidate genes hypothesized to be linked to FVL in a subgroup of FVL carriers with extreme sperm count values. The animal studies consisted of never mated 15-18-week-old C57BL/J6 mice heterozygous and homozygous for FVL and wild-type mice. We compared spermatogenesis parameters (normalized internal genitalia weights, epididymis sperm content and sperm motility) between FVL and wild-type mice. Human FVL carriers have a higher total sperm

  1. The impact of finger counting habits on arithmetic in adults and children.

    Science.gov (United States)

    Newman, Sharlene D; Soylu, Firat

    2014-07-01

    Here, we explored the impact of finger counting habits on arithmetic in both adults and children. Two groups of participants were examined, those that begin counting with their left hand (left-starters) and those that begin counting with their right hand (right-starters). For the adults, performance on an addition task in which participants added 2 two-digit numbers was compared. The results revealed that left-starters were slower than right-starters when adding and they had lower forward and backward digit-span scores. The children (aged 5-12) showed similar results on a single-digit timed addition task-right-starters outperformed left-starters. However, the children did not reveal differences in working memory or verbal and non-verbal intelligence as a function of finger counting habit. We argue that the motor act of finger counting influences how number is represented and suggest that left-starters may have a more bilateral representation that accounts for the slower processing.

  2. How Fred Hoyle Reconciled Radio Source Counts and the Steady State Cosmology

    Science.gov (United States)

    Ekers, Ron

    2012-09-01

    In 1969 Fred Hoyle invited me to his Institute of Theoretical Astronomy (IOTA) in Cambridge to work with him on the interpretation of the radio source counts. This was a period of extreme tension with Ryle just across the road using the steep slope of the radio source counts to argue that the radio source population was evolving and Hoyle maintaining that the counts were consistent with the steady state cosmology. Both of these great men had made some correct deductions but they had also both made mistakes. The universe was evolving, but the source counts alone could tell us very little about cosmology. I will try to give some indication of the atmosphere and the issues at the time and look at what we can learn from this saga. I will conclude by briefly summarising the exponential growth of the size of the radio source counts since the early days and ask whether our understanding has grown at the same rate.

  3. Comment on: 'A Poisson resampling method for simulating reduced counts in nuclear medicine images'.

    Science.gov (United States)

    de Nijs, Robin

    2015-07-21

    In order to be able to calculate half-count images from already acquired data, White and Lawson published their method based on Poisson resampling. They verified their method experimentally by measurements with a Co-57 flood source. In this comment their results are reproduced and confirmed by a direct numerical simulation in Matlab. Not only Poisson resampling, but also two direct redrawing methods were investigated. Redrawing methods were based on a Poisson and a Gaussian distribution. Mean, standard deviation, skewness and excess kurtosis half-count/full-count ratios were determined for all methods, and compared to the theoretical values for a Poisson distribution. Statistical parameters showed the same behavior as in the original note and showed the superiority of the Poisson resampling method. Rounding off before saving of the half count image had a severe impact on counting statistics for counts below 100. Only Poisson resampling was not affected by this, while Gaussian redrawing was less affected by it than Poisson redrawing. Poisson resampling is the method of choice, when simulating half-count (or less) images from full-count images. It simulates correctly the statistical properties, also in the case of rounding off of the images.

  4. Peak-counts blood flow model-errors and limitations

    International Nuclear Information System (INIS)

    Mullani, N.A.; Marani, S.K.; Ekas, R.D.; Gould, K.L.

    1984-01-01

    The peak-counts model has several advantages, but its use may be limited due to the condition that the venous egress may not be negligible at the time of peak-counts. Consequently, blood flow measurements by the peak-counts model will depend on the bolus size, bolus duration, and the minimum transit time of the bolus through the region of interest. The effect of bolus size on the measurement of extraction fraction and blood flow was evaluated by injecting 1 to 30ml of rubidium chloride in the femoral vein of a dog and measuring the myocardial activity with a beta probe over the heart. Regional blood flow measurements were not found to vary with bolus sizes up to 30ml. The effect of bolus duration was studied by injecting a 10cc bolus of tracer at different speeds in the femoral vein of a dog. All intravenous injections undergo a broadening of the bolus duration due to the transit time of the tracer through the lungs and the heart. This transit time was found to range from 4-6 second FWHM and dominates the duration of the bolus to the myocardium for up to 3 second injections. A computer simulation has been carried out in which the different parameters of delay time, extraction fraction, and bolus duration can be changed to assess the errors in the peak-counts model. The results of the simulations show that the error will be greatest for short transit time delays and for low extraction fractions

  5. Efficiency calibration of a liquid scintillation counter for 90Y Cherenkov counting

    International Nuclear Information System (INIS)

    Vaca, F.; Garcia-Leon, M.

    1998-01-01

    In this paper a complete and self-consistent method for 90 Sr determination in environmental samples is presented. It is based on the Cherenkov counting of 90 Y with a conventional liquid scintillation counter. The effects of color quenching on the counting efficiency and background are carefully studied. A working curve is presented which allows to quantify the correction in the counting efficiency depending on the color quenching strength. (orig.)

  6. Colour quenching corrections on the measurement of 90Sr through Cerenkov counting

    International Nuclear Information System (INIS)

    Mosqueda, F.; Villa, M.; Vaca, F.; Bolivar, J.P.

    2007-01-01

    The determination of 90 Sr through the Cerenkov radiation emitted by its descendant 90 Y is a well-known method and firmly established in literature. Nevertheless, in order to obtain an accurate result based on a Cerenkov measurement, the experimental work must be extremely rigorous because the efficiency of Cerenkov counting is especially sensitive to the presence of colour. Any traces of colour in the sample produce a decrease in the number of photons detected in the photomultipliers and, therefore, this might cause a diminution in Cerenkov counting efficiency. It is essential not only to detect the effect of colour quenching in the sample but also to correct the decrease in counting efficiency. For this reason, colour quenching correction curves versus counting efficiency are usually done when measuring through Cerenkov counting. One of the most widely used techniques to evaluate colour quenching in these measurements is the channel ratio method, which consists of the measurement of the shift of the spectrum measuring the ratio of counts in two different windows. The selection of the windows for the application of the corrections might have an influence on the quality of the fitting parameters of the correction curves efficiency versus colour quenching degree and hence on the final 90 Sr result. This work is focused on the calculation of the counting efficiency decrease using the channel ratio method and on obtaining the best fitting correction curve. For this purpose, empirical curves obtained through artificial quenchers have been studied and the results have been tested in real samples. Additionally, given that the Packard Tri-Carb 3170 TR/SL liquid scintillation counter is a novel detector for use in Cerenkov counting, the previous calibration of the Tri-Carb 3170 TR/SL detector, necessary for the measurement of 90 Sr, is included

  7. Haematological changes in HIV infection with correlation to CD4 cell count

    Directory of Open Access Journals (Sweden)

    SS Parinitha

    2012-03-01

    Full Text Available BackgroundHIV infection is associated with a wide range of haematological abnormalities.Methods and ObjectivesThe objectives in this study were to study haematological changes in HIV patients and to correlate them with CD4 cell counts. Two hundred and fifty HIV positive patients referred to the haematology laboratory section for complete haemogram in whom CD4 count was done were included in the study. Haematologic parameters and CD4 counts were studied in each of these patients.Descriptive statistics were applied. Association between two attributes was calculated by chi-square test and p value less than 0.05 was considered statistically significant.ResultsAmong 250 patients, anaemia was seen in 210 (84% cases. The most common type was normocytic normochromic (40.4%. Lymphopenia was seen in 163 (65.2% cases and thrombocytopenia in 45 (18% cases. The majority of cases (70% had CD4 cell counts below 200 cells/mm3. Fifty-four cases (21.6% had CD4 counts between 200 to 499 cells/mm3 and 21 (8.4% cases had CD4 counts more than 500 cells/ mm3.In patients with CD4 counts less than 200 cells/mm3, anaemia was seen in 91.4% cases, leucopenia in 26.8%cases, lymphopenia in 80% cases and thrombocytopenia in 21.7% cases.ConclusionHaematologic manifestations of HIV infection are common and more frequent with progression of disease. The present study revealed a significant increase in the number of cases of anaemia, and lymphopenia, with decreasing CD4 cell counts. Thrombocytopenia is also seen but does not show significant increase with disease progression. The study also highlights the importance of simultaneously treating HIV patients for haematologic manifestations to reduce morbidity.

  8. CD4 T lymphocyte counts in patients undergoing splenectomy during living donor liver transplantation.

    Science.gov (United States)

    Natsuda, Koji; Eguchi, Susumu; Takatsuki, Mistuhisa; Soyama, Akihiko; Hidaka, Masaaki; Hara, Takanobu; Kugiyama, Tota; Baimakhanov, Zhassulan; Ono, Shinichiro; Kitasato, Amane; Fujita, Fumihiko; Kanetaka, Kengo; Kuroki, Tamotsu

    2016-02-01

    The role of splenectomy in increasing the CD4-positive T lymphocyte counts (hereafter: CD4 counts) and the CD4 to CD8 ratio have not yet been fully investigated, especially in the case of HIV-positive patients undergoing liver transplantation (LT). The change in the total lymphocyte counts of 32 patients who underwent one-stage splenectomy with living donor (LD) LT with (n=13) or without rituximab (RTX, n=19) therapy were examined to validate our cohort of ABO-incompatible LDLT with RTX. Subsequently, perioperative changes in CD4 counts and the CD 4 to CD8 ratio were measured in 13 patients who underwent ABO-incompatible LDLT/RTX with splenectomy. (1) The administration of RTX did not significantly affect the total lymphocyte counts of patients after LDLT/splenectomy in any of the observation periods. (2) The CD4 counts were significantly higher at 2years after LDLT in comparison to the perioperative CD4 counts but not within the 3-month period (p=0.039). The CD4/CD8 ratio gradually decreased after LDLT/splenectomy under RTX treatment. An immediate increase in the CD4 counts therefore cannot be expected after LDLT with splenectomy. The total lymphocyte and CD4 counts were rather stable in the peritransplant period even in ABO incompatible LDLT with RTX. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. 25 CFR 12.36 - Does other law enforcement training count?

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Does other law enforcement training count? 12.36 Section 12.36 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR LAW AND ORDER INDIAN COUNTRY LAW ENFORCEMENT Qualifications and Training Requirements § 12.36 Does other law enforcement training count? All requests for evaluation of equivalent...

  10. Fast pulse discriminator for photon counting at high photon densities

    International Nuclear Information System (INIS)

    Benoit, R.; Pedrini, A.

    1977-03-01

    A fast tunnel diode discriminator for photon counting up to 200MHz count frequency is described. The tunnel diode is operated on its apparent I.V. characteristics displayed when the diode is driven into its oscillating region. The pulse shaper-discriminator is completely D.C. coupled in order to avoid base-line shift at high pulse rates

  11. Estimation of atomic interaction parameters by photon counting

    DEFF Research Database (Denmark)

    Kiilerich, Alexander Holm; Mølmer, Klaus

    2014-01-01

    Detection of radiation signals is at the heart of precision metrology and sensing. In this article we show how the fluctuations in photon counting signals can be exploited to optimally extract information about the physical parameters that govern the dynamics of the emitter. For a simple two......-level emitter subject to photon counting, we show that the Fisher information and the Cram\\'er- Rao sensitivity bound based on the full detection record can be evaluated from the waiting time distribution in the fluorescence signal which can, in turn, be calculated for both perfect and imperfect detectors...

  12. Recommendations for monitoring avian populations with point counts: a case study in southeastern Brazil

    Directory of Open Access Journals (Sweden)

    Vagner Cavarzere

    2013-01-01

    Full Text Available In the northern hemisphere, bird counts have been fundamental in gathering data to understand population trends. Due to the seasonality of the northern hemisphere, counts take place during two clearly defined moments in time: the breeding season (resident birds and winter (after migration. Depending on location, Neotropical birds may breed at any time of year, may or may not migrate, and those patterns are not necessarily synchronous among species. Also in contrast to the northern hemisphere, population trends and the impact of rapid urbanization and deforestation are unknown and unmonitored. Throughout one year, we used point counts to better understand temporal patterns of bird species richness and relative abundance in the state of São Paulo, southeastern Brazil, to examine how to implement similar bird counts in tropical America. We counted birds twice each day on 10 point transects (20 points day‑1, separated by 200 m, with a 100 m limited detection radius in a semideciduous tropical forest. Both species richness and bird abundance were greater in the morning, but accumulation curves suggest that longer-duration afternoon counts would reach the same total species as in morning counts. Species richness and bird abundance did not vary seasonally and unique species were counted every month; relatively few species (20% were present in all months. Most (84% known forest species in the area were encountered. We suggest that point counts can work here as they do in the northern hemisphere. We recommend that transects include at least 20 points and that the simplest timing of bird counts would also be seasonal, using timing of migration of austral migrants (and six months later to coordinate counts. We propose that bird counts in Brazil, and elsewhere in Latin America, would provide data to help understand population trends, but would require greater effort than in temperate latitudes due to greater species richness and different dynamics of

  13. L-041: EPR-First Responders: Establishment of zones and Emergency Facilities

    International Nuclear Information System (INIS)

    2011-01-01

    This conference is about the specific areas and facilities in a radiological emergency such as safety zones, inner cordoned area, public information center, a contamination control area and a temporary morgue area

  14. A Next Generation Digital Counting System For Low-Level Tritium Studies (Project Report)

    International Nuclear Information System (INIS)

    Bowman, P.

    2016-01-01

    Since the early seventies, SRNL has pioneered low-level tritium analysis using various nuclear counting technologies and techniques. Since 1999, SRNL has successfully performed routine low-level tritium analyses with counting systems based on digital signal processor (DSP) modules developed in the late 1990s. Each of these counting systems are complex, unique to SRNL, and fully dedicated to performing routine tritium analyses of low-level environmental samples. It is time to modernize these systems due to a variety of issues including (1) age, (2) lack of direct replacement electronics modules and (3) advances in digital signal processing and computer technology. There has been considerable development in many areas associated with the enterprise of performing low-level tritium analyses. The objective of this LDRD project was to design, build, and demonstrate a Next Generation Tritium Counting System (NGTCS), while not disrupting the routine low-level tritium analyses underway in the facility on the legacy counting systems. The work involved (1) developing a test bed for building and testing new counting system hardware that does not interfere with our routine analyses, (2) testing a new counting system based on a modern state of the art DSP module, and (3) evolving the low-level tritium counter design to reflect the state of the science.

  15. A Vision-Based Counting and Recognition System for Flying Insects in Intelligent Agriculture

    Directory of Open Access Journals (Sweden)

    Yuanhong Zhong

    2018-05-01

    Full Text Available Rapid and accurate counting and recognition of flying insects are of great importance, especially for pest control. Traditional manual identification and counting of flying insects is labor intensive and inefficient. In this study, a vision-based counting and classification system for flying insects is designed and implemented. The system is constructed as follows: firstly, a yellow sticky trap is installed in the surveillance area to trap flying insects and a camera is set up to collect real-time images. Then the detection and coarse counting method based on You Only Look Once (YOLO object detection, the classification method and fine counting based on Support Vector Machines (SVM using global features are designed. Finally, the insect counting and recognition system is implemented on Raspberry PI. Six species of flying insects including bee, fly, mosquito, moth, chafer and fruit fly are selected to assess the effectiveness of the system. Compared with the conventional methods, the test results show promising performance. The average counting accuracy is 92.50% and average classifying accuracy is 90.18% on Raspberry PI. The proposed system is easy-to-use and provides efficient and accurate recognition data, therefore, it can be used for intelligent agriculture applications.

  16. Fast counting electronics for neutron coincidence counting

    International Nuclear Information System (INIS)

    Swansen, J.E.

    1987-01-01

    This patent describes a high speed circuit for accurate neutron coincidence counting comprising: neutron detecting means for providing an above-threshold signal upon neutron detection; amplifying means inputted by the neutron detecting means for providing a pulse output having a pulse width of about 0.5 microseconds upon the input of each above threshold signal; digital processing means inputted by the pulse output of the amplifying means for generating a pulse responsive to each input pulse from the amplifying means and having a pulse width of about 50 nanoseconds effective for processing an expected neutron event rate of about 1 Mpps: pulse stretching means inputted by the digital processing means for producing a pulse having a pulse width of several milliseconds for each pulse received form the digital processing means; visual indicating means inputted by the pulse stretching means for producing a visual output for each pulse received from the digital processing means; and derandomizing means effective to receive the 50 ns neutron event pulses from the digital processing means for storage at a rate up to the neutron event rate of 1 Mpps and having first counter means for storing the input neutron event pulses

  17. Characterization of spectrometric photon-counting X-ray detectors at different pitches

    Science.gov (United States)

    Jurdit, M.; Brambilla, A.; Moulin, V.; Ouvrier-Buffet, P.; Radisson, P.; Verger, L.

    2017-09-01

    There is growing interest in energy-sensitive photon-counting detectors based on high flux X-ray imaging. Their potential applications include medical imaging, non-destructive testing and security. Innovative detectors of this type will need to count individual photons and sort them into selected energy bins, at several million counts per second and per mm2. Cd(Zn)Te detector grade materials with a thickness of 1.5 to 3 mm and pitches from 800 μm down to 200 μm were assembled onto interposer boards. These devices were tested using in-house-developed full-digital fast readout electronics. The 16-channel demonstrators, with 256 energy bins, were experimentally characterized by determining spectral resolution, count rate, and charge sharing, which becomes challenging at low pitch. Charge sharing correction was found to efficiently correct X-ray spectra up to 40 × 106 incident photons.s-1.mm-2.

  18. Why calories count: from science to politics

    National Research Council Canada - National Science Library

    Nestle, Marion; Nesheim, Malden C

    2012-01-01

    .... They are also hard to understand. In Why Calories Count, Marion Nestle and Malden Nesheim explain in clear and accessible language what calories are and how they work, both biologically and politically...

  19. Photon Counting Using Edge-Detection Algorithm

    Science.gov (United States)

    Gin, Jonathan W.; Nguyen, Danh H.; Farr, William H.

    2010-01-01

    New applications such as high-datarate, photon-starved, free-space optical communications require photon counting at flux rates into gigaphoton-per-second regimes coupled with subnanosecond timing accuracy. Current single-photon detectors that are capable of handling such operating conditions are designed in an array format and produce output pulses that span multiple sample times. In order to discern one pulse from another and not to overcount the number of incoming photons, a detection algorithm must be applied to the sampled detector output pulses. As flux rates increase, the ability to implement such a detection algorithm becomes difficult within a digital processor that may reside within a field-programmable gate array (FPGA). Systems have been developed and implemented to both characterize gigahertz bandwidth single-photon detectors, as well as process photon count signals at rates into gigaphotons per second in order to implement communications links at SCPPM (serial concatenated pulse position modulation) encoded data rates exceeding 100 megabits per second with efficiencies greater than two bits per detected photon. A hardware edge-detection algorithm and corresponding signal combining and deserialization hardware were developed to meet these requirements at sample rates up to 10 GHz. The photon discriminator deserializer hardware board accepts four inputs, which allows for the ability to take inputs from a quadphoton counting detector, to support requirements for optical tracking with a reduced number of hardware components. The four inputs are hardware leading-edge detected independently. After leading-edge detection, the resultant samples are ORed together prior to deserialization. The deserialization is performed to reduce the rate at which data is passed to a digital signal processor, perhaps residing within an FPGA. The hardware implements four separate analog inputs that are connected through RF connectors. Each analog input is fed to a high-speed 1

  20. CANOPY STRUCTURE AND DEPOSITION EFFICIENCY OF VINEYARD SPRAYERS

    Directory of Open Access Journals (Sweden)

    Gianfranco Pergher

    2007-06-01

    Full Text Available A field study was performed to analyse how deposition efficiency from an axial-fan sprayer was affected by the canopy structure of vines trained to the High Cordon, Low Cordon and Casarsa systems, at beginning of flowering and beginning of berry touch growth stages. An empirical calibration method, providing a dose rate adjustment roughly proportional to canopy height, was used. The canopy structure was assessed using the Point Quadrat method, and determining the leaf area index (LAI and the leaf layer index (LLI. Spray deposits were measured by colorimetry, using a water soluble dye (Tartrazine as a tracer. Correlation between deposits and canopy parameters were analysed and discussed. Foliar deposits per unit leaf area were relatively constant, suggesting that empirical calibration can reduce deposit variability associated with different training systems and growth stages. Total foliar deposition ranged from 33.6% and 82.3% of total spray volume, and increased proportionally with the LLI up to LLI<4. Deposits on bunches significantly decreased with the LLI in the grape zone. The results suggest that sprayer efficiency is improved by a regular, symmetrical canopy, with few leaf layers in the grape zone as in Low Cordon. However, a LLI<3 over the whole canopy and >40% gaps in the foliage both reduced total deposition, and may increase the risk for larger drift losses.

  1. Automatic vehicle counting system for traffic monitoring

    Science.gov (United States)

    Crouzil, Alain; Khoudour, Louahdi; Valiere, Paul; Truong Cong, Dung Nghy

    2016-09-01

    The article is dedicated to the presentation of a vision-based system for road vehicle counting and classification. The system is able to achieve counting with a very good accuracy even in difficult scenarios linked to occlusions and/or presence of shadows. The principle of the system is to use already installed cameras in road networks without any additional calibration procedure. We propose a robust segmentation algorithm that detects foreground pixels corresponding to moving vehicles. First, the approach models each pixel of the background with an adaptive Gaussian distribution. This model is coupled with a motion detection procedure, which allows correctly location of moving vehicles in space and time. The nature of trials carried out, including peak periods and various vehicle types, leads to an increase of occlusions between cars and between cars and trucks. A specific method for severe occlusion detection, based on the notion of solidity, has been carried out and tested. Furthermore, the method developed in this work is capable of managing shadows with high resolution. The related algorithm has been tested and compared to a classical method. Experimental results based on four large datasets show that our method can count and classify vehicles in real time with a high level of performance (>98%) under different environmental situations, thus performing better than the conventional inductive loop detectors.

  2. Do your syringes count?

    International Nuclear Information System (INIS)

    Brewster, K.

    2002-01-01

    Full text: This study was designed to investigate anecdotal evidence that residual Sestamibi (MIBI) activity vaned in certain situations. For rest studies different brands of syringes were tested to see if the residuals varied. The period of time MIBI doses remained in the syringe between dispensing and injection was also considered as a possible source of increased residual counts. Stress Mibi syringe residual activities were measured to assess if the method of stress test affected residual activity. MIBI was reconstituted using 13 Gbq of Technetium in 3mls of normal saline then boiled for 10 minutes. Doses were dispensed according to department protocol and injected via cannula. Residual syringes were collected for three syringe types. In each case the barrel and plunger were measured separately. As the syringe is flushed during the exercise stress test and not the pharmacological stress test the chosen method was recorded. No relationship was demonstrated between the time MIBI remained in a syringe prior to injection and residual activity. Residual activity was not affected by method of stress test used. Actual injected activity can be calculated if the amount of activity remaining in the syringe post injection is known. Imaging time can be adjusted for residual activity to optimise count statistics. Preliminary results in this study indicate there is no difference in residual activity between syringe brands.Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  3. Generalized estimators of avian abundance from count survey data

    Directory of Open Access Journals (Sweden)

    Royle, J. A.

    2004-01-01

    Full Text Available I consider modeling avian abundance from spatially referenced bird count data collected according to common protocols such as capture-recapture, multiple observer, removal sampling and simple point counts. Small sample sizes and large numbers of parameters have motivated many analyses that disregard the spatial indexing of the data, and thus do not provide an adequate treatment of spatial structure. I describe a general framework for modeling spatially replicated data that regards local abundance as a random process, motivated by the view that the set of spatially referenced local populations (at the sample locations constitute a metapopulation. Under this view, attention can be focused on developing a model for the variation in local abundance independent of the sampling protocol being considered. The metapopulation model structure, when combined with the data generating model, define a simple hierarchical model that can be analyzed using conventional methods. The proposed modeling framework is completely general in the sense that broad classes of metapopulation models may be considered, site level covariates on detection and abundance may be considered, and estimates of abundance and related quantities may be obtained for sample locations, groups of locations, unsampled locations. Two brief examples are given, the first involving simple point counts, and the second based on temporary removal counts. Extension of these models to open systems is briefly discussed.

  4. Poor prognostic role of the pretreatment platelet counts in colorectal cancer: A meta-analysis.

    Science.gov (United States)

    Rao, Xu-Dong; Zhang, Hua; Xu, Zheng-Shui; Cheng, Hua; Shen, Wei; Wang, Xin-Ping

    2018-06-01

    Recently, a wide variety of studies have suggested that elevated platelet counts are associated with survival in patients with colorectal cancer. On one hand several studies suggest a negative connection in colorectal cancer patients with pre-operative thrombocytosis, on the other hand other studies contradicts this. However, it remains unknown whether elevated platelet counts are associated with survival in colorectal cancer patients. We therefore conducted this meta-analysis to evaluate the prognostic role of platelet counts in colorectal cancer. PubMed, Embase, and the Cochrane Library databases were searched from their inception to October 15, 2016 to identify relevant studies that have explored the prognostic role of platelet counts in colorectal cancer. Studies that examined the association between platelet counts and prognoses in colorectal cancer and that provided a hazard ratio (HR) and 95% confidence interval (CI) for overall survival (OS) and/or disease-free survival (DFS) were included. This meta-analysis included 9 retrospective cohort studies involving 3413 patients with colorectal cancer. OS was shorter in patients with elevated platelet counts than in patients with normal counts (HR 2.11, 95% CI: 1.68-2.65). For DFS, an elevated platelet count was also a poor predictor (HR 2.51, 95% CI: 1.84-3.43). In this meta-analysis, we suggest that an elevated platelet count is a negative predictor of survival in both primary colorectal cancer and resectable colorectal liver metastases.

  5. Liquid scintillation alpha counting and spectrometry and its application to bone and tissue samples

    International Nuclear Information System (INIS)

    McDowell, W.J.; Weiss, J.F.

    1976-01-01

    Three methods for determination of alpha-emitting nuclides using liquid scintillation counting are compared, and the pertinent literature is reviewed. Data showing the application of each method to the measurement of plutonium concentration in tissue and bone samples are presented. Counting with a commercial beta-liquid scintillation counter and an aqueous-phase-accepting scintillator is shown to be accurate only in cases where the alpha activity is high (several hundred counts/min or more), only gross alpha counting is desired, and beta-gamma emitters are known to be absent from the sample or present at low levels compared with the alpha activity. Counting with the same equipment and an aqueous immiscible scintillator containing an extractant for the nuclide of interest (extractive scintillator) is shown to allow better control of alpha peak shift due to quenching, a significant reduction of beta-gamma interference, and, usually, a low background. The desirability of using a multichannel pulse-height analyzer in the above two counting methods is stressed. The use of equipment and procedures designed for alpha liquid scintillation counting is shown to allow alpha spectrometry with an energy resolution capability of 200 to 300 keV full-peak-width-at-half-peak-height and a background of 0.3 to 1.0 counts/min, or as low as 0.01 counts/min if pulse-shape discrimination methods are used. Methods for preparing animal bone and tissue samples for assay are described

  6. Automation of Sample Transfer and Counting on Fast Neutron ActivationSystem

    International Nuclear Information System (INIS)

    Dewita; Budi-Santoso; Darsono

    2000-01-01

    The automation of sample transfer and counting were the transfer processof the sample to the activation and counting place which have been done byswitch (manually) previously, than being developed by automaticallyprogrammed logic instructions. The development was done by constructed theelectronics hardware and software for that communication. Transfer timemeasurement is on seconds and was done automatically with an error 1.6 ms.The counting and activation time were decided by the user on seconds andminutes, the execution error on minutes was 8.2 ms. This development systemwill be possible for measuring short half live elements and cyclic activationprocesses. (author)

  7. Correction for intrinsic and set dead-time losses in radioactivity counting

    International Nuclear Information System (INIS)

    Wyllie, H.A.

    1992-12-01

    Equations are derived for the determination of the intrinsic dead time of the components which precede the paralysis unit in a counting system for measuring radioactivity. The determination depends on the extension of the set dead time by the intrinsic dead time. Improved formulae are given for the dead-time correction of the count rate of a radioactive source in a single-channel system. A variable in the formulae is the intrinsic dead time which is determined concurrently with the counting of the source. The only extra equipment required in a conventional system is a scaler. 5 refs., 2 tabs., 21 figs

  8. Pulse-duration discrimination for increasing counting characteristic plateau and for improving counting rate stability of a scintillation counter

    International Nuclear Information System (INIS)

    Kuz'min, M.G.

    1977-01-01

    For greater stability of scintillation counters operation, discussed is the possibility for increasing the plateau and reducing its slope. Presented is the circuit for discrimination of the signal pulses from input pulses of a photomultiplier. The counting characteristics have been measured with the scintillation detectors being irradiated by different gamma sources ( 60 Co, 137 Cs, 241 Am) and without the source when the scintillation detector is shielded by a tungsten cylinder with a wall thickness of 23 mm. The comparison has revealed that discrimination in duration increase the plateau and reduces its slope. Proceeding from comparison of the noise characteristics, the relationship is found between the noise pulse number and gamma radiation energy. For better stability of the counting rate it is suggested to introduce into the scintillation counter the circuit for duration discrimination of the output pulses of a photomultiplier

  9. Nutritional status, quality of life and CD4 cell count of adults living ...

    African Journals Online (AJOL)

    Keywords: CD4 cell count; Quality of Life; adults; nutritional status; nutritional intake. Nutritional status .... used to calculate the Body Mass Index (BMI). BMI was ... fat consumption as a percentage of the total food energy intake, and component ..... except when the CD4 counts fall very low.5,27 The CD4 cell count may offer a ...

  10. Count data, detection probabilities, and the demography, dynamics, distribution, and decline of amphibians.

    Science.gov (United States)

    Schmidt, Benedikt R

    2003-08-01

    The evidence for amphibian population declines is based on count data that were not adjusted for detection probabilities. Such data are not reliable even when collected using standard methods. The formula C = Np (where C is a count, N the true parameter value, and p is a detection probability) relates count data to demography, population size, or distributions. With unadjusted count data, one assumes a linear relationship between C and N and that p is constant. These assumptions are unlikely to be met in studies of amphibian populations. Amphibian population data should be based on methods that account for detection probabilities.

  11. What counts? Visual and verbal cues interact to influence what is considered a countable thing.

    Science.gov (United States)

    Chesney, Dana L; Gelman, Rochel

    2015-07-01

    Many famous paintings illustrate variations in what we here dub "referential depth." For example, paintings often include not only portrayals of uniquely referenced items, but also reflections of those items in mirrors or other polished surfaces. If a painting includes both a dancer and that dancer's reflection in a mirror, are there one or two dancers in the painting? Although there are two images of a dancer, both images reference the exact same dancer. Consequently, counting both may seem to violate the constraint against double counting (Gelman & Gallistel, 1978). This illustrates that determining which things "count" in a given context may not be straightforward. Here we used counting tasks paired with illustrations that manipulated referential depth to investigate the conceptual, perceptual, and language variables that may influence whether a "thing" is a "countable thing." Across four experiments, 316 participants counted items in displays that included both foreground items and items placed inside mirrors, picture frames, and windows. Referential depth and frame boundaries both influenced counting: For one thing, participants were more likely to count items contained by windows than by picture frames or mirrors. Moreover, items in mirrors were rarely counted unless they were interpreted as reflections of items "off screen." Also, the items contained inside windows were sometimes (~10% of trials) excluded from the counts, when counting them would require crossing frame boundaries. We concluded that conceptual and perceptual contexts both influence people's decisions about the physical boundaries of the to-be-counted set and which items within these boundaries are countable.

  12. Undercooling, nodule count and carbides in thin walled ductile cast iron

    DEFF Research Database (Denmark)

    Pedersen, Karl Martin; Tiedje, Niels Skat

    2008-01-01

    Ductile cast iron has been cast in plate thicknesses between 2 to 8 mm. The temperature has been measured during the solidification and the graphite nodule count and size distribution together with the type and amount of carbides have been analysed afterwards. Low nodule count gives higher...

  13. Refined tropical curve counts and canonical bases for quantum cluster algebras

    DEFF Research Database (Denmark)

    Mandel, Travis

    We express the (quantizations of the) Gross-Hacking-Keel-Kontsevich canonical bases for cluster algebras in terms of certain (Block-Göttsche) weighted counts of tropical curves. In the process, we obtain via scattering diagram techniques a new invariance result for these Block-Göttsche counts....

  14. Clustering method for counting passengers getting in a bus with single camera

    Science.gov (United States)

    Yang, Tao; Zhang, Yanning; Shao, Dapei; Li, Ying

    2010-03-01

    Automatic counting of passengers is very important for both business and security applications. We present a single-camera-based vision system that is able to count passengers in a highly crowded situation at the entrance of a traffic bus. The unique characteristics of the proposed system include, First, a novel feature-point-tracking- and online clustering-based passenger counting framework, which performs much better than those of background-modeling-and foreground-blob-tracking-based methods. Second, a simple and highly accurate clustering algorithm is developed that projects the high-dimensional feature point trajectories into a 2-D feature space by their appearance and disappearance times and counts the number of people through online clustering. Finally, all test video sequences in the experiment are captured from a real traffic bus in Shanghai, China. The results show that the system can process two 320×240 video sequences at a frame rate of 25 fps simultaneously, and can count passengers reliably in various difficult scenarios with complex interaction and occlusion among people. The method achieves high accuracy rates up to 96.5%.

  15. A New Method for Calculating Counts in Cells

    Science.gov (United States)

    Szapudi, István

    1998-04-01

    In the near future, a new generation of CCD-based galaxy surveys will enable high-precision determination of the N-point correlation functions. The resulting information will help to resolve the ambiguities associated with two-point correlation functions, thus constraining theories of structure formation, biasing, and Gaussianity of initial conditions independently of the value of Ω. As one of the most successful methods of extracting the amplitude of higher order correlations is based on measuring the distribution of counts in cells, this work presents an advanced way of measuring it with unprecedented accuracy. Szapudi & Colombi identified the main sources of theoretical errors in extracting counts in cells from galaxy catalogs. One of these sources, termed as measurement error, stems from the fact that conventional methods use a finite number of sampling cells to estimate counts in cells. This effect can be circumvented by using an infinite number of cells. This paper presents an algorithm, which in practice achieves this goal; that is, it is equivalent to throwing an infinite number of sampling cells in finite time. The errors associated with sampling cells are completely eliminated by this procedure, which will be essential for the accurate analysis of future surveys.

  16. Characterization of spectrometric photon-counting X-ray detectors at different pitches

    International Nuclear Information System (INIS)

    Jurdit, M.; Moulin, V.; Ouvrier-Buffet, P.; Verger, L.; Brambilla, A.; Radisson, P.

    2017-01-01

    There is growing interest in energy-sensitive photon-counting detectors based on high flux X-ray imaging. Their potential applications include medical imaging, non-destructive testing and security. Innovative detectors of this type will need to count individual photons and sort them into selected energy bins, at several million counts per second and per mm 2 . Cd(Zn)Te detector grade materials with a thickness of 1.5 to 3 mm and pitches from 800 μm down to 200 μm were assembled onto interposer boards. These devices were tested using in-house-developed full-digital fast readout electronics. The 16-channel demonstrators, with 256 energy bins, were experimentally characterized by determining spectral resolution, count rate, and charge sharing, which becomes challenging at low pitch. Charge sharing correction was found to efficiently correct X-ray spectra up to 40 × 10 6 incident photons.s −1 .mm −2 .

  17. Bayesian inference from count data using discrete uniform priors.

    Directory of Open Access Journals (Sweden)

    Federico Comoglio

    Full Text Available We consider a set of sample counts obtained by sampling arbitrary fractions of a finite volume containing an homogeneously dispersed population of identical objects. We report a Bayesian derivation of the posterior probability distribution of the population size using a binomial likelihood and non-conjugate, discrete uniform priors under sampling with or without replacement. Our derivation yields a computationally feasible formula that can prove useful in a variety of statistical problems involving absolute quantification under uncertainty. We implemented our algorithm in the R package dupiR and compared it with a previously proposed Bayesian method based on a Gamma prior. As a showcase, we demonstrate that our inference framework can be used to estimate bacterial survival curves from measurements characterized by extremely low or zero counts and rather high sampling fractions. All in all, we provide a versatile, general purpose algorithm to infer population sizes from count data, which can find application in a broad spectrum of biological and physical problems.

  18. High sensitivity neutron activation analysis using coincidence counting method

    International Nuclear Information System (INIS)

    Suzuki, Shogo; Okada, Yukiko; Hirai, Shoji

    1999-01-01

    Four kinds of standard samples such as river sediment (NIES CRM No.16), Typical Japanese Diet, otoliths and river water were irradiated by TRIGA-II (100 kW, 3.7x10 12 n cm -2 s -1 ) for 6 h. After irradiation and cooling, they were analyzed by the coincidence counting method and a conventional γ-ray spectrometry. Se, Ba and Hf were determined by 75 Se 265 keV, 131 Ba 496 keV and 181 Hf 482 keV. On the river sediment sample, Ba and Hf showed the same values by two methods, but Se value contained Ta by the conventional method, although the coincidence counting method could analyze Se. On Typical Japanese Diet and otoliths, Se could be determined by two methods and Ba and Hf determined by the coincidence counting method but not determined by the conventional method. Se value in the river water agreed with the authorization value. (S.Y.)

  19. Low white blood cell count and cancer

    Science.gov (United States)

    ... gov/ency/patientinstructions/000675.htm Low white blood cell count and cancer To use the sharing features on this page, please enable JavaScript. White blood cells (WBCs) fight infections from bacteria, viruses, fungi, and ...

  20. Optimization of time-correlated single photon counting spectrometer

    International Nuclear Information System (INIS)

    Zhang Xiufeng; Du Haiying; Sun Jinsheng

    2011-01-01

    The paper proposes a performance improving scheme for the conventional time-correlated single photon counting spectrometer and develops a high speed data acquisition card based on PCI bus and FPGA technologies. The card is used to replace the multi-channel analyzer to improve the capability and decrease the volume of the spectrometer. The process of operation is introduced along with the integration of the spectrometer system. Many standard samples are measured. The experimental results show that the sensitivity of the spectrometer is single photon counting, and the time resolution of fluorescence lifetime measurement can be picosecond level. The instrument could measure the time-resolved spectroscopy. (authors)

  1. Liquid scintillation counting (LSC) - an overview

    International Nuclear Information System (INIS)

    Ravi, S.; Mathew, K.M.

    2005-01-01

    In Liquid Scintillation Counting, the amount of light produced is proportional to the amount of radiation present in the sample and the energy of the light produced is proportional to the energy of the radiation that is present in the sample. This makes LSC a very convenient tool to measure radioactivity

  2. Investigation on Carbohydrate Counting Method in Type 1 Diabetic Patients

    Directory of Open Access Journals (Sweden)

    Osman Son

    2014-01-01

    Full Text Available Objective. The results from Diabetes Control and Complications Trial (DCCT have propounded the importance of the approach of treatment by medical nutrition when treating diabetes mellitus (DM. During this study, we tried to inquire carbohydrate (Kh count method’s positive effects on the type 1 DM treatment’s success as well as on the life quality of the patients. Methods. 22 of 37 type 1 DM patients who applied to Eskişehir Osmangazi University, Faculty of Medicine Hospital, Department of Endocrinology and Metabolism, had been treated by Kh count method and 15 of them are treated by multiple dosage intensive insulin treatment with applying standard diabetic diet as a control group and both of groups were under close follow-up for 6 months. Required approval was taken from the Ethical Committee of Eskişehir Osmangazi University, Medical Faculty, as well as informed consent from the patients. The body weight of patients who are treated by carbohydrate count method and multiple dosage intensive insulin treatment during the study beginning and after 6-month term, body mass index, and body compositions are analyzed. A short life quality and medical research survey applied. At statistical analysis, t-test, chi-squared test, and Mann-Whitney U test were used. Results. There had been no significant change determined at glycemic control indicators between the Kh counting group and the standard diabetic diet and multiple dosage insulin treatment group in our study. Conclusion. As a result, Kh counting method which offers a flexible nutrition plan to diabetic individuals is a functional method.

  3. ChromAIX2: A large area, high count-rate energy-resolving photon counting ASIC for a Spectral CT Prototype

    Science.gov (United States)

    Steadman, Roger; Herrmann, Christoph; Livne, Amir

    2017-08-01

    Spectral CT based on energy-resolving photon counting detectors is expected to deliver additional diagnostic value at a lower dose than current state-of-the-art CT [1]. The capability of simultaneously providing a number of spectrally distinct measurements not only allows distinguishing between photo-electric and Compton interactions but also discriminating contrast agents that exhibit a K-edge discontinuity in the absorption spectrum, referred to as K-edge Imaging [2]. Such detectors are based on direct converting sensors (e.g. CdTe or CdZnTe) and high-rate photon counting electronics. To support the development of Spectral CT and show the feasibility of obtaining rates exceeding 10 Mcps/pixel (Poissonian observed count-rate), the ChromAIX ASIC has been previously reported showing 13.5 Mcps/pixel (150 Mcps/mm2 incident) [3]. The ChromAIX has been improved to offer the possibility of a large area coverage detector, and increased overall performance. The new ASIC is called ChromAIX2, and delivers count-rates exceeding 15 Mcps/pixel with an rms-noise performance of approximately 260 e-. It has an isotropic pixel pitch of 500 μm in an array of 22×32 pixels and is tile-able on three of its sides. The pixel topology consists of a two stage amplifier (CSA and Shaper) and a number of test features allowing to thoroughly characterize the ASIC without a sensor. A total of 5 independent thresholds are also available within each pixel, allowing to acquire 5 spectrally distinct measurements simultaneously. The ASIC also incorporates a baseline restorer to eliminate excess currents induced by the sensor (e.g. dark current and low frequency drifts) which would otherwise cause an energy estimation error. In this paper we report on the inherent electrical performance of the ChromAXI2 as well as measurements obtained with CZT (CdZnTe)/CdTe sensors and X-rays and radioactive sources.

  4. Smart pile-up consideration for evaluation of high count rate EDS spectra

    International Nuclear Information System (INIS)

    Eggert, F; Anderhalt, R; Nicolosi, J; Elam, T

    2012-01-01

    This work describes a new pile-up consideration for the very high count rate spectra which are possible to acquire with silicon drift detector (SDD) technology. Pile-up effects are the major and still remaining challenge with the use of SDD for EDS in scanning electron microscopes (SEM) with ultra thin windows for soft X-ray detection. The ability to increase the count rates up to a factor of 100 compared with conventional Si(Li) detectors, comes with the problem that the pile-up recognition (pile-up rejection) in pulse processors is not able to improve by the same order of magnitude, just only with a factor of about 3. Therefore, it is common that spectra will show significant pile-up effects if count rates of more than 10000 counts per second (10 kcps) are used. These false counts affect both automatic qualitative analysis and quantitative evaluation of the spectra. The new idea is to use additional inputs for pile-up calculation to shift the applicability towards very high count rates of up to 200 kcps and more, which can be easily acquired with the SDD. The additional input is the 'known' (estimated) background distribution, calculated iteratively during all automated qualitative or quantitative evaluations. This additional knowledge gives the opportunity for self adjustment of the pile-up calculation parameters and avoids over-corrections which challenge the evaluation as well as the pile-up artefacts themselves. With the proposed method the pile-up correction is no longer a 'correction' but an integral part of all spectra evaluation steps. Examples for the application are given with evaluation of very high count rate spectra.

  5. The increase in leucocyte count during menstruation is a function of ...

    African Journals Online (AJOL)

    Menstruation is an endocrine mediated physiologic cyclical bleeding per vagina in a non-pregnant woman of the reproductive age group. Blood is a good culture medium for bacteria and as such, menstruation can affect leucocytes count. This study is aimed at evaluating leucocytes count during menstruation. Fifty-eight ...

  6. 26 CFR 1.963-3 - Distributions counting toward a minimum distribution.

    Science.gov (United States)

    2010-04-01

    ... earnings and profits and 100 shares of only one class of stock outstanding. Domestic corporation M, not... distribution of earnings and profits which is attributable to an increase in current earnings, invested in... counting toward a minimum distribution. (a) Conditions under which earnings and profits are counted toward...

  7. Variants of the Borda count method for combining ranked classifier hypotheses

    NARCIS (Netherlands)

    van Erp, Merijn; Schomaker, Lambert; Schomaker, Lambert; Vuurpijl, Louis

    2000-01-01

    The Borda count is a simple yet effective method of combining rankings. In pattern recognition, classifiers are often able to return a ranked set of results. Several experiments have been conducted to test the ability of the Borda count and two variant methods to combine these ranked classifier

  8. Evaluation of Petrifilm Lactic Acid Bacteria Plates for Counting Lactic Acid Bacteria in Food.

    Science.gov (United States)

    Kanagawa, Satomi; Ohshima, Chihiro; Takahashi, Hajime; Burenqiqige; Kikuchi, Misato; Sato, Fumina; Nakamura, Ayaka; Mohamed, Shimaa M; Kuda, Takashi; Kimura, Bon

    2018-06-01

    Although lactic acid bacteria (LAB) are used widely as starter cultures in the production of fermented foods, they are also responsible for food decay and deterioration. The undesirable growth of LAB in food causes spoilage, discoloration, and slime formation. Because of these adverse effects, food companies test for the presence of LAB in production areas and processed foods and consistently monitor the behavior of these bacteria. The 3M Petrifilm LAB Count Plates have recently been launched as a time-saving and simple-to-use plate designed for detecting and quantifying LAB. This study compares the abilities of Petrifilm LAB Count Plates and the de Man Rogosa Sharpe (MRS) agar medium to determine the LAB count in a variety of foods and swab samples collected from a food production area. Bacterial strains isolated from Petrifilm LAB Count Plates were identified by 16S rDNA sequence analysis to confirm the specificity of these plates for LAB. The results showed no significant difference in bacterial counts measured by using Petrifilm LAB Count Plates and MRS medium. Furthermore, all colonies growing on Petrifilm LAB Count Plates were confirmed to be LAB, while yeast colonies also formed in MRS medium. Petrifilm LAB Count Plates eliminated the plate preparation and plate inoculation steps, and the cultures could be started as soon as a diluted food sample was available. Food companies are required to establish quality controls and perform tests to check the quality of food products; the use of Petrifilm LAB Count Plates can simplify this testing process for food companies.

  9. Quality of raw cow milk in Republic of Macedonia determined through the testing of somatic cell count and total viable count

    Directory of Open Access Journals (Sweden)

    Angelovski Ljupco

    2008-11-01

    Full Text Available Somatic cells count and total viable count are criteria used to estimate the compliance of raw cow milk with the Book of rules for demands for safety and hygiene and procedures for official controls of milk and milk products, Official Gazette of RM 157/2007. According to the given demands, raw milk operators are obliged to conduct all procedures and to guarantee that milk is in compliance with the criteria laid down in Book of rules. At the same time, Republic of Macedonia have to fulfill EU criteria laid down in Directive 92/46 (Council directive 92/46/EEC laying down the health rules for the production and placing on the market of raw milk, heat-treated milk and milkbased products for quality of raw milk as part of implementation of community legislation and milk production. The independent laboratory for milk quality control at FVM-Skopje, in frame of its activities in the period February- August 2008 has conducted a study for obtaining preliminary results for the situation with raw milk quality produced in R. of Macedonia for somatic cells counts and total viable count. In the study we analyzed 2065 samples for TVC and 1625 samples for SCC of raw milk samples produced in different parts of the country. From the tested samples only 41,8% fulfill criteria for SCC and 41,45% criteria for TVC lay down in Book of rules for 2008. Assessment of the results in light of Council Directive it is obvious that only 42,7% of the samples for SCC and 10,7% for TVC fulfill the criteria of Council Directive having in mind different requirements vs. Book of rules.

  10. Count-to-count time interval distribution analysis in a fast reactor; Estudio de la distribucion de intervalos de tiempo entre detecciones consecutivas de neutrones en un reactor rapido

    Energy Technology Data Exchange (ETDEWEB)

    Perez-Navarro Gomez, A

    1973-07-01

    The most important kinetic parameters have been measured at the zero power fast reactor CORAL-I by means of the reactor noise analysis in the time domain, using measurements of the count-to-count time intervals. (Author) 69 refs.

  11. Recubrimiento de Stellite 6 sobre acero inoxidable realizado con láser de CO2 para válvulas de escape de motores diesel

    Directory of Open Access Journals (Sweden)

    Cadenas, M.

    2002-12-01

    Full Text Available To reduce the recovery or the replacement costs of diesel engine exhaust valves, they are manufactured with an economic base material, and a coating which is deposited on the seat valve in order to reach high hardness and good impact, corrosion and high temperature wear resistance (>550 °C and without lubrication. In this work, appropriate laser cladding parameters have been determined to obtain Stellite 6 coatings over AISI 304 steel (as plane test specimens and SAE EV8 steel (as valves substrates. One and two superimposed tracks were deposited on the seat valves, and modifying the laser power as a function of the rotated angle at the beginning and the end of the circular tracks, pores and cracks have been minimized and the thickness of the track were made uniform. Hardness, dilution and final microstructure of the different coatings have been analysed. A 10 % dilution and 550 HV in the tracks over plane test specimens was observed, while valves with one track showed 25 % and 430 HV respectively. With two superimposed tracks the hardness was up to 470 HV in the upper track.

    Para abaratar el coste de recuperación o sustitución de válvulas de escape en motores diesel, estas se fabrican con un material base económico, recubriéndose el asiento de la válvula con otro material al que se exigirá elevada dureza y buena resistencia al impacto, a la corrosión y al desgaste erosivo en caliente (>550 °C y sin lubricación. Partiendo de esta idea, en el presente trabajo se han determinado los parámetros adecuados para realizar, mediante la técnica de plaqueado láser, un recubrimiento con Stellite 6, sobre sustratos de acero AISI 304 (probetas planas y SAE EV8 (válvulas reales. Sobre las válvulas, se depositaron uno y dos cordones superpuestos, se minimizó la presencia de poros y grietas, modificando el grado de solape inicial y final de los cordones circulares y la potencia en función del ángulo girado. Así, se

  12. Reduction of CMOS Image Sensor Read Noise to Enable Photon Counting.

    Science.gov (United States)

    Guidash, Michael; Ma, Jiaju; Vogelsang, Thomas; Endsley, Jay

    2016-04-09

    Recent activity in photon counting CMOS image sensors (CIS) has been directed to reduction of read noise. Many approaches and methods have been reported. This work is focused on providing sub 1 e(-) read noise by design and operation of the binary and small signal readout of photon counting CIS. Compensation of transfer gate feed-through was used to provide substantially reduced CDS time and source follower (SF) bandwidth. SF read noise was reduced by a factor of 3 with this method. This method can be applied broadly to CIS devices to reduce the read noise for small signals to enable use as a photon counting sensor.

  13. Going Online to Make Learning Count

    Science.gov (United States)

    Brigham, Cathy; Klein-Collins, Rebecca

    2011-01-01

    Adult students often come to higher education with college-level learning that they have acquired outside of the classroom--from the workplace, military service, self-study, or hobbies. For decades, many forward-thinking colleges and universities have been offering services to evaluate that learning and award it college credit that counts towards…

  14. A comparison of point counts with a new acoustic sampling method ...

    African Journals Online (AJOL)

    We showed that the estimates of species richness, abundance and community composition based on point counts and post-hoc laboratory listening to acoustic samples are very similar, especially for a distance limited up to 50 m. Species that were frequently missed during both point counts and listening to acoustic samples ...

  15. Characterization Of The Alpha/Beta Counting System Type MPC 9400 And Its Utilization

    International Nuclear Information System (INIS)

    Makhsum; Sutarman; Fikri, Hanif; Handoko, Djati

    2000-01-01

    Have been carried out the experiment to determine the operation voltage, instrument stability, counting efficiency, figure of merit, and minimum detectable activity. This instrument used to count gross alpha and gross beta. This instrument belongs good stability at the confidence level of 95 % and the background count that was 0,144 cpm for alpha and 22,65 cpm for beta. The counting efficiency was 27,41 % (electrodeposition of Am-241), 6,57 % (deposition of Am-241), 51,82 % (deposition of Sr-90). The limit of detectable activity was 1,04 x 10 exp.-2 Bq (electrodeposition of Am-241), 4,35 x 10 exp.-2 Bq (% deposition of Sr 90)

  16. Influence of the type of milking and storage of milk on the chem ical composition, Somatic Cell Count and bacterial count Total

    Directory of Open Access Journals (Sweden)

    Aline Leite Peixoto

    2017-03-01

    Full Text Available The refrigeration of milk and the usage of mechanical milking are important to obtain milk in accordance with quality standards. In this work we evaluated the influence of the type of milking process and type of storage on the quality of the refrigerated milk. It was obtained 1363 refrigerated milk samples stored in single or collective expansion tanks, from manually or mechanically milked animals. The experiment was carried out in a 2x2 randomized factorial scheme. Two types of expansion tanks (single and collective and two types of milking (manual and mechanical. The average comparison test and Tukey test was carried out with 95% confidence. The levels of fat, protein, lactose and defatted dry extract, were evaluated according to the type of milking and type of milk storage. The values obtained were higher when compared to the values stabilished by the Ministry of Agriculture, Livestock and Food Supply. The level of milk fat was higher in samples with somatic cell count above 501,000 SC/mL. However, the levels of protein and defatted dry extract were higher in samples with somatic cell count below 500,000 SC/mL. The type of milking and the type of storage have influence on parameters related to milk quality such as levels of fat, protein, lactose and somatic cell count. The milk chemical composition revealed in accordance with the values stabilished by the Brazilian legislation. The total bacterial count did not vary with storage type nor the type of milking.

  17. Dependence of a whole body counting efficiency on body size and composition

    International Nuclear Information System (INIS)

    Venturini, Luzia; Campos, Vicente P.; Berti, Eduardo A.R.

    2001-01-01

    An approach is described to evaluate the counting efficiency dependence, on the geometry measurement and on the material density, for whole body measurement. The counting efficiency is evaluated using Monte Carlo Method to simulate the history of the photons, from its emission to its total absorption or escape from the detector. Theoretical calculations of the counting efficiency are presented for two phantoms of the BOMAB family. The phantoms are considered to be filled with water and with a material constituted as described by Snyder et al. (author)

  18. Dependence of a whole body counting efficiency on body size and composition

    Energy Technology Data Exchange (ETDEWEB)

    Venturini, Luzia; Campos, Vicente P.; Berti, Eduardo A.R. [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)

    2001-07-01

    An approach is described to evaluate the counting efficiency dependence, on the geometry measurement and on the material density, for whole body measurement. The counting efficiency is evaluated using Monte Carlo Method to simulate the history of the photons, from its emission to its total absorption or escape from the detector. Theoretical calculations of the counting efficiency are presented for two phantoms of the BOMAB family. The phantoms are considered to be filled with water and with a material constituted as described by Snyder et al. (author)

  19. Cognitive Processes Related to Counting in Students with Special Educational Needs

    Science.gov (United States)

    Carrasumada, S.; Vendrell, R.; Ribera, G.; Montserrat, M.

    2006-01-01

    This study is aimed at the mechanisms used by students with an intellectual disability in the counting process. The assessment of the counting process is carried out through experimental tests inspired by the basic principles of Gelman and Gallistel, namely one-to-one, stable order, cardinality, abstraction and order irrelevance. This is a…

  20. Pedestrian Counting with Occlusion Handling Using Stereo Thermal Cameras

    DEFF Research Database (Denmark)

    Kristoffersen, Miklas Strøm; Dueholm, Jacob Velling; Gade, Rikke

    2016-01-01

    and the complexity of scenes with many people occluding one another. To address these challenges, this paper introduces the use of a stereo thermal camera setup for pedestrian counting. We investigate the reconstruction of 3D points in a pedestrian street with two thermal cameras and propose an algorithm......The number of pedestrians walking the streets or gathered in public spaces is a valuable piece of information for shop owners, city governments, event organizers and many others. However, automatic counting that takes place day and night is challenging due to changing lighting conditions...