WorldWideScience

Sample records for coombs test

  1. Coombs test

    Science.gov (United States)

    Direct antiglobulin test; Indirect antiglobulin test; Anemia - hemolytic ... No special preparation is necessary for this test. ... There are 2 types of the Coombs test: Direct Indirect The direct ... that are stuck to the surface of red blood cells. Many diseases ...

  2. 21 CFR 864.9300 - Automated Coombs test systems.

    Science.gov (United States)

    2010-04-01

    ... Blood and Blood Products § 864.9300 Automated Coombs test systems. (a) Identification. An automated Coombs test system is a device used to detect and identify antibodies in patient sera or antibodies bound... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automated Coombs test systems. 864.9300 Section...

  3. Evaluation of a New and Rapid Serologic Test for Detecting Brucellosis: Brucella Coombs Gel Test.

    Science.gov (United States)

    Hanci, Hayrunisa; Igan, Hakan; Uyanik, Muhammet Hamidullah

    2017-01-01

    Many serological tests have been used for the diagnosis of human brucellosis. A new serological method is identified as Brucella Coombs gel test based on the principle of centrifugation gel system similar to the gel system used in blood group determination. In this system, if Brucella antibodies were present in the serum, antigen and antibody would remain as a pink complex on the gel. Otherwise, the pink Brucella antigens would precipitate at the bottom of the gel card system. In this study, we aimed to compare the Brucella Coombs gel test, a new, rapid screen and titration method for detection of non-agglutinating IgG with the Brucella Coombs test. For this study, a total of 88 serum samples were obtained from 45 healthy persons and 43 individuals who had clinical signs and symptoms of brucellosis. For each specimen, Rose Bengal test, standard agglutination test, Coombs test and Brucella Coombs gel test were carried out. Sensitivity and specificity of Brucella Coombs gel test were found as 100.0 and 82.2%, respectively. Brucella Coombs gel test can be used as a screening test with high sensitivity. By the help of pink Brucella antigen precipitation, the tests' evaluation is simple and objective. In addition, determination of Brucella antibody by rapid titration offers another important advantage.

  4. Comparison of a New and Rapid Method: Brucella Coombs Gel Test With Other Diagnostic Tests.

    Science.gov (United States)

    Kalem, Fatma; Ergün, Ayşe Gül; Durmaz, Süleyman; Doğan, Metin; Ertuğrul, Ömür; Gündem, Seval

    2016-09-01

    The aim of this study was to detect reliability of Brucella Coombs gel test (BCGT) by comparing with with ELISA (IgG + IgM), Standard agglutination test, and Brucella immunocapture agglutination methods in serological diagnosis of brucellosis. Brucella Coombs gel test (BCGT), Brucella ELISA (IgG + IgM), Standard agglutination test, and Brucella immunocapture agglutination tests of 78 patients with presumptive diagnosis of brucellosis which were sent to Microbiology Laboratory of Konya Numune Hospital from various regions of Konya were studied. Of 78 patients with ELISA IgG and IgM, STA, BICA and BCGT; 26, 21, 10, 12 and 12 were positive. When compared with BICA, the sensitivity and specifity of BCGT were 100% and 100%, respectively. According to results BCGT can be used as a diagnostic test in routine laboratories after more comprehensive studies in control groups and patients. © 2016 Wiley Periodicals, Inc.

  5. Detection of thrombocytic antibodies with the direct and indirect haemolysis inhibition test and the radioimmuno-Coombs test

    International Nuclear Information System (INIS)

    Mettenboerger, D.; Vith, E.

    1982-01-01

    Methods of application of the direct and indirect haemolysis inhibition test were studied in order to optimise the test parameters: The ultimate aim was to standardize the test method and compare its sensitivity in detecting various platelet antibodies with platelet indirect radioactive Coombs-test and the platelet immunofluorescence test. (orig.) [de

  6. Immune thrombocytopenia. Use of a Coombs antiglobulin test to detect IgG and C3 on platelets

    International Nuclear Information System (INIS)

    Cines, D.B.; Schreiber, A.D.

    1979-01-01

    We applied a radiolabeled Coombs antiglobulin test to the diagnosis and management of immune thrombocytopenia in adults and children. This assay substantiated that the majority of patients with idiopathic thrombocytopenic purpura have increased levels of IgG on their platelets. Platelets from a patient with the post-transfusion-purpura syndrome also carried increased IgG, indicating a role for IgG antibody or IgG-containing immune complexes in the destruction of host platelets in this disease. The radiolabeled Coombs test provides a general means to help diagnose, manage, and study immune platelet disorders

  7. Coombs Antiglobulin Test Using Brucella abortus 99 as Antigen To Detect Incomplete Antibodies Induced by B. abortus RB51 Vaccine in Cattle

    OpenAIRE

    Ciuchini, Franco; Adone, Rosanna; Pasquali, Paolo

    2002-01-01

    This study showed that vaccination of cattle with Brucella abortus rough strain RB51 induces incomplete antibodies that can be detectable by a Coombs antiglobulin test using the B. abortus 99 smooth strain.

  8. [Positive Distribution Rate of Coombs Test in Patients with Clinical Anemia and Blood Transfusion and Its Effect on Clinical Blood Transfusion].

    Science.gov (United States)

    Wu, Gang; Duan, Yu-Han

    2018-02-01

    To study the positive distribution rate of Coombs test in patients with clinical anemia and blood transfusion, and its effect on clinical blood transfusion. Seventy patients with hemoglobin level in the normal range were enrolled into control group, while 130 patients with anemia or blood transfusion who' s hemoglobin level was lower comfirmed by micro-column gel antihuman globin detection card and 70 surgical patients with anemia or blood transfusion who' s hemoglobin level was lower comfirmed by micro-column gel anti-human globin card were enrolled into anemia or blood transfusion (A or BT) group. And coomb' s test performed for all the patients, in which the positive patients in Department of Internal Medicine need to be re-typed. Among 70 surgical patients with anemia or blood transfusion, 14 cases were directly detected to be anti-human globine positive with detection rate 20%; among 130 internal medicine patients with anemia or blood transfusion, 54 cases were directly detected to be anti-human globine positive with detection rate 41.4%. Among 270 cases, the highest positive rate (66.7%) was observed in patients with 50-59 g/L of hemoglobin. According to type test, the samples of 54 patients with anemia in Department of Internal Medicine, who were directly selected to be anti-human globin positive, could be divided into anti-C3d(7 cases, accounting for 13.0%), anti-IgG(12 cases accounting for, 22.2%) and anti-C3d+anti-IgG(35 cases, accounting for 64.8%), while according to diseases, the anti-human globin positive ratio was high in tumor cancer, hephropathy and gastroenteropathy patients, and patients in intensive care unit, moreover the blood transfusion frequency of these patients was higher than that of patients with anti-human globin negative(Pblood transfusion, so as to ensure the effectiveness of blood transfusion.

  9. Service-Learning in Crisis Communication Education: Revisiting Coombs' Objectives for the Crisis Communication Course

    Science.gov (United States)

    Maresh-Fuehrer, Michelle M.

    2015-01-01

    The purpose of this study was to revisit Coombs' suggestions for teaching the crisis communication course using service-learning as a framework. The author sought to assess the effectiveness of using this method in terms of the benefits to both students and the partnering organization and students' perceptions of whether they met the learning…

  10. The F. E. College and the Community. Coombe Lodge Report Volume 7 Number 6. Study Conference 74/14.

    Science.gov (United States)

    Further Education Staff Coll., Blagdon (England).

    Speakers at the Coombe Lodge study conference covered a wide range of subjects related to the continuing education college and the community. They include: adult education: the Russell Report, the community, and the college (D. J. Moore); the FE college and the community (A.N. Fairbairn); the Abraham Moss Centre (R. Mitson); the community college…

  11. A case of coombs-positive severe late anemia without hyperbilirubinemia, refractory to blood transfusion, improved with immunoglobulin

    Directory of Open Access Journals (Sweden)

    Supriya Kushwah

    2017-01-01

    Full Text Available Rhesus hemolytic disease of newborn is a well-known disease with early and late complications mainly manifesting as severe hyperbilirubinemia requiring prompt treatment such as exchange transfusion and immunoglobulins. We report a case of Coombs-positive severe late anemia without hyperbilirubinemia which presented with features such as sepsis and failure to gain weight. Baby was refractory to blood transfusion initially, but later on successfully improved with immunoglobulins.

  12. Evaluation of an Immunocapture-Agglutination Test (Brucellacapt) for Serodiagnosis of Human Brucellosis

    Science.gov (United States)

    Orduña, Antonio; Almaraz, Ana; Prado, Ana; Gutierrez, M. Purificación; Garcia-Pascual, Agustina; Dueñas, Ana; Cuervo, Milagros; Abad, Ramon; Hernández, Beatriz; Lorenzo, Belen; Bratos, Miguel A.; Torres, Antonio Rodriguez

    2000-01-01

    We evaluated the validity and the usefulness of a new test for the diagnosis of human brucellosis based on an immunocapture-agglutination technique. A total of 315 sera from 82 patients with a diagnosis of brucellosis, 157 sera from patients in whom brucellosis was suspected but not confirmed, and 412 sera from people living in rural areas with endemic brucellosis were studied. The seroagglutination test (SAT), Coombs anti-Brucella test, and Brucellacapt test were evaluated. All the initial sera from the 82 patients proved to be positive in Brucellacapt and Coombs tests, while only 75 (91.4%) were positive in the SAT. If a ≥1/160 diagnostic threshold titer was defined for the Brucellacapt test, Coombs test, and SAT, the sensitivities were 95.1, 91.5, and 65.8%, respectively. Taking the same diagnostic threshold titer for the 157 sera from the unconfirmed but suspected patients, the specificities of the Brucellacapt, Coombs, and SAT were 81.5, 96.2, and 100%, respectively; for the 412 control sera, the specificities were 99.0, 99.8, and 100%. The diagnostic efficiency (area below the receiver operating characteristic curve) of Brucellacapt was 0.987852 (95% confidence interval [CI], 0.95109 to 0.99286), very similar to the diagnostic efficiency of the Coombs test (0.97611; 95% CI, 0.94781 to 0.99146) and higher than that of SAT (0.91013; 95% CI, 0.86649 to 0.94317). The results of the Brucellacapt test were compared with those of the Coombs test (correlation coefficient, 0.956; P = 0.000) and SAT (correlation coefficient, 0.866; P = 0.000). The study shows very good correlation between the Brucellacapt and Coombs tests, with a high concordance between titers obtained in the two tests. Nevertheless, lower correlation and concordance were found between the Brucellacapt and Coombs tests when the results for titers of ≥1/160 were compared (0.692; P = 0.000). In acute brucellosis, the Brucellacapt and Coombs tests render positive titers of ≥1/160. When the titers

  13. Diagnostic Efficacy of Modified Coagglutination Test in the Diagnosis of Human Brucellosis

    Directory of Open Access Journals (Sweden)

    Mohite S.T

    2013-07-01

    Full Text Available Background: Laboratory help is must for thediagnosis of human brucellosis due to proteanclinical manifestations. As culture is hazardous,time consuming and less sensitive, serologicaltests are preferred for the diagnosis. Aggluti-nation tests like Rose Bengal PlateTest (RBPT, Serum Agglutination tests (SAT,2-Mercaptoethanol test (2-ME that are com-monly employed for the diagnosis either lacksensitivity or specificity. Coombs test andBrucellacapt though are sensitive and specific,workout costly. Therefore, modifiedcoagglutination test was developed and its di-agnostic efficacy was evaluated. Aims and Ob-jectives: To develop modified coagglutinationtest for the diagnosis of human brucellosis andcompare it with Coombs test. Materials andMethods: Serum samples collected from 191brucellosis patients and 100 controls were sub-jected to 2-ME, Coombs test and modifiedcoagglutination test (MCOAG. Blood culturewas performed by Castaneda’s method in all thepatients. Results: Significant difference in thepositivity rate was seen between MCOAG and2-ME. The results of MCOAG were compa-rable with Coombs test. Conclusions: Modi-fied coagglutination test is a better option toCoombs test for the serodiagnosis of brucel-losis in resource constrained countries as it issensitive, specific and cost effective.

  14. BrucellaCapt versus classical tests in the serological diagnosis and management of human brucellosis.

    Science.gov (United States)

    Casanova, Aurora; Ariza, Javier; Rubio, Manuel; Masuet, Cristina; Díaz, Ramón

    2009-06-01

    The BrucellaCapt test is an immunocapture agglutination test suggested as a possible substitute for the Coombs test in the diagnosis of human brucellosis. Here it is compared with classical tests using 321 samples from 48 patients with brucellosis (6.9 +/- 1.7 samples per patient), including 20 patients with focal disease and 8 patients with a total of 9 relapse episodes (mean follow-up, 18 months). The BrucellaCapt test was used according to the manufacturer's instructions, and we also used a variant of the BrucellaCapt test in which the microtiter plates were not coated with antibodies against total human immunoglobulin (BCAPV). The correlation between the BrucellaCapt and BCAPV tests was 0.982 (P < 0.001), with 260 coincident pairs of titers (81%). The areas under the receiver operating characteristic curve for the BrucellaCapt and BCAPV tests with respect to the Coombs test were 0.969 and 0.960, respectively. Upon admission, the BrucellaCapt, BCAPV, and Coombs tests and the microagglutination test (MAT) were positive for all cases: titers were 1/2,560 by the BrucellaCapt test, 1/2,560 by the BCAPV test, 1/1,280 by the Coombs test, and 1/320 by the MAT. The decreases in the BrucellaCapt and BCAPV titers over time were pronounced in comparison with the Coombs titers. Cumulative probabilities of persistence 12 months after therapy were as follows: 80% by the BrucellaCapt test, 80% by the BCAPV test, 87% by the Coombs test, and 35% by the MAT. Serological changes during relapse were detected in seven cases (88%) by the Coombs test, in five cases by the BrucellaCapt and BCAPV tests, and in three cases by the MAT. The BrucellaCapt test is a sensitive, specific, and simple test for routine use in human brucellosis. Similar results were obtained with the BCAPV test. However, in some cases of relapse and chronic forms of the disease, the slight changes observed in low-affinity antibodies alone are better detected by the Coombs test.

  15. Avifaunal diversity and bird community responses to man-made habitats in St. Coombs Tea Estate, Sri Lanka

    Directory of Open Access Journals (Sweden)

    J. Dananjaya Kottawa-Arachchi

    2015-02-01

    Full Text Available A survey on birds was conducted at St. Coombs Tea Estate, Talawakelle, Sri Lanka with the objective of assessing the avifaunal diversity of a given tea plantation ecosystem. Bird populations were sampled in man-made habitats such as home garden, wetland, tea plantation, Eucalyptus plantation and small scale reservoir. Hundred-and-twenty counts were made for each habitat and in addition, activities of birds, feeding habits and food recourses were also observed. A total of 87 species, including 11 endemic and 11 migrant species of birds, was recorded, which included one globally threatened species, Kashmir Flycatcher Ficedula subrubra and 16 nationally threatened species. A majority of the bird species were observed in home gardens (75%, followed by reservoirs (57%, wetlands (48%, tea plantations (43% and in Eucalyptus plantations (23%. Home gardens support bird diversity while the species richness of endemic bird species increases thereby enabling these findings to be used as guidelines in long term conservational practices. Several conservation measures such as increasing plant diversity, introduction of shade trees and prevention of fire are recommended to conserve and enhance avifaunal diversity in tea plantations.

  16. The false sero-negativity of brucella standard agglutination test: Prozone phenomenon

    Directory of Open Access Journals (Sweden)

    İrfan Binici

    2011-12-01

    Full Text Available Objectives: We aimed to assess prozone phenomenon that is quite rare and causes false negativity in serological diagnosisof brucellosis with standard dilution titers.Materials and methods: In this study the tests of four cases that have false negative serological results were evaluated.Blood cultures were obtained from all cases while cerebrospinal fluid cultures were studied in the two cases. Standardagglutination test (SAT and Coombs test were performed to all patients.Results: SAT and Coombs test was negative in titers up to 1/640 in all cases. The SAT and Coombs tests in cerebrospinalfluid (CSF of the two cases with neurobrucellosis diagnosis were negative, as well. Since the clinical and laboratoryfindings suggested the brucellosis, the serums were restudied by diluting up to 1/10240 titer and we saw that the first3 cases became positive at a titer of 1/1280. The fourth case remained negative and therefore, we applied high dilutionCoombs test. This time the test gave a positive result at 1/10240 titer beginning from 1/2560 titer. B.melitensis wasisolated from two cases.Conclusion: SAT and Coombs’ test must be diluted to titers 1/2560 or more in order to exclude false sero-negativity incases with clinical and laboratory findings suggesting brucellosis. J Microbiol Infect Dis 2011; 1(3:110-113

  17. On the Equivalence of Constructed-Response and Multiple-Choice Tests.

    Science.gov (United States)

    Traub, Ross E.; Fisher, Charles W.

    Two sets of mathematical reasoning and two sets of verbal comprehension items were cast into each of three formats--constructed response, standard multiple-choice, and Coombs multiple-choice--in order to assess whether tests with indentical content but different formats measure the same attribute, except for possible differences in error variance…

  18. The use of the rapid osmotic fragility test as an additional test to diagnose canine immune-mediated haemolytic anaemia

    DEFF Research Database (Denmark)

    Paes, Geert; Paepe, Dominique; Meyer, Evelyne

    2013-01-01

    Background: Diagnosing canine immune-mediated haemolytic anaemia (IMHA) is often challenging because all currently available tests have their limitations. Dogs with IMHA often have an increased erythrocyte osmotic fragility (OF), a characteristic that is sometimes used in the diagnosis of IMHA...... hyperlipemic dogs (group 3), 10 dogs with lymphoma (group 4), 8 dogs with an infection (group 5) and 13 healthy dogs (group 6) were included. In all dogs, blood smear examination, in-saline auto-agglutination test, Coombs' test, COFT and ROFT were performed. In the COFT, OF5, OF50 and OF90 were defined...

  19. Solución adyuvante CM-95 tratada magnéticamente en comparación con el adyuvante de Freund para la obtención del suero de Coombs en conejo

    Directory of Open Access Journals (Sweden)

    Clara Martínez

    2009-12-01

    Full Text Available En este trabajo se evaluó la aplicación de la solución CM-95 tratada magnéticamente como adyuvante inmunológico, en comparación con el adyuvante de Freund, para la obtención del suero de Coombs en conejos, de gran demanda en bancos de sangre y hospitales, para el diagnóstico clínico de conflictos Rh y la enfermedad hemolítica del recién nacido, entre otras. Conejos Nueva Zelanda Blancos se inocularon por la vía subcutánea con suero humano obtenido de 30 donantes O+, unido con la solución CM-95 tratada magnéticamente como adyuvante inmunológico. Se empleó un esquema de inmunización de 40 días, donde se evaluó la dinámica en el título de anticuerpos anti IgG humano por la técnica de hemoaglutinación en tubos. Al antisuero se le determinó la calidad inmunológica por el título de heteroaglutininas de los grupos sanguíneos A, B y O, de anticuerpos anticomplemento C3b, C3d y C4b y anti IgG, antes y después de su purificación. El suero de Coombs con la solución adyuvante CM-95 tratada magnéticamente mostró valores similares a los obtenidos con el adyuvante de Freund. En el mismo se cumplió con los requisitos establecidos por el Centro Estatal para el Control de la Calidad de los Medicamentos, según las normativas de la FDA para este diagnosticador. Estos resultados abren nuevas perspectivas para el uso de la solución adyuvante en la obtención del suero de Coombs.

  20. Socialisation into Organizations. Coombe Lodge Working Paper.

    Science.gov (United States)

    Turner, C. M.

    Four aspects of the process of an individual's socialization into a new organization are examined: characteristics, stages, content, and practice. Socialization is defined as the process by which an individual comes to appreciate the values, abilities, expected behaviors, and social knowledge essential for assuming an organizational role and for…

  1. Test

    DEFF Research Database (Denmark)

    Bendixen, Carsten

    2014-01-01

    Bidrag med en kortfattet, introducerende, perspektiverende og begrebsafklarende fremstilling af begrebet test i det pædagogiske univers.......Bidrag med en kortfattet, introducerende, perspektiverende og begrebsafklarende fremstilling af begrebet test i det pædagogiske univers....

  2. Prognosis in canine idiopathic immune-mediated haemolytic anaemia

    NARCIS (Netherlands)

    Piek, C.J.

    2011-01-01

    Canine idiopathic immune-mediated haemolytic anaemia (iIMHA) is one of the most frequently occurring immune-mediated diseases in dogs. A gel-based Coombs' test was shown to perform equally well as a classical Coombs' test. Since the gel-based Coombs' test can be commercially produced and is easy and

  3. Diagnostic Tests in Human Brucellosis

    Directory of Open Access Journals (Sweden)

    Hamid Reza Nouri

    2014-07-01

    Full Text Available Context: Brucellosis represents a zoonotic bacterial disease, caused by a gram negative bacterium called Brucella. Between the diverses pecies of this bacteria, B. melitensis, B. abortus, B. suis and B. canis consist the main causes of the disease in humans.More than half a million new cases of Brucellosis are reported annually. Consequently, brucellosis is a remarkable threat for the health of society. Because of the multiple nonspecific clinical signs of this infection, such as fever (60% of cases, night sweating, insomnia and anorexia, which are similar to other diseases, the detection of brucellosis is time-consuming and needs more scrutiny. Evidence Acquisition: Blood culture is considered the gold standard for the detection of brucellosis and the sensitivity of this test in the acute form is high. However, for the chronic type of disease, it is remarkably low, in addition, in some cases, it needs long reaction times. Nevertheless, today, some kinds of tests like automatic culturing system and serological methods, such as Rose Bengal (RB test, serum agglutination test (SAT, 2-mercaptoethanol (2ME and coombs, which are operated based on agglutination, are useful for the problems mentioned earlier. Conclusion: Although serological methods are common for the diagnosis of brucellosis, false results are observable for several methods, such as the SAT method. Tests like the enzyme-linked immunosorbent assay (ELISA, for the screening of specific traits, although confirmed, have their advantages and defects. The lateral flow assay (LFA shows promising evidence to be effective in the diagnosis of brucellosis. The polymerase chain reaction (PCR is more prevalent than other common tests, according to sensitivity and fast answering potency in case of molecular diagnosis. Also, PCR is proper for patients' follow-up during the period of treatment and crimination of relapse by this method is easier compared to others.

  4. A radiolabeled antiglobulin test for crossmatching platelet transfusions

    International Nuclear Information System (INIS)

    Kickler, T.S.; Braine, H.G.; Ness, P.M.; Koester, A.; Bias, W.

    1983-01-01

    Despite the use of HLA-matched platelets for alloimmunized recipients, transfusion failures occur. In order to reduce these failures, researchers investigated the use of a radiolabeled antiglobulin technique for platelet crossmatching. The principle of the test is that of an indirect Coombs test using 125 I labeled goat anti-human IgG. Incompatibility is determined by calculating a radioactivity antiglobulin test (RAGT) index. Using this technique, researchers performed 89 crossmatches on 19 leukemic or aplastic patients who were refractory to random donor platelets and receiving varying degrees of HLA-matched platelets. Effectiveness of the transfusion was assessed from the posttransfusion corrected platelet count increment (CCI) determined at 1 and 20 hr. When the RAGT index was 1.9 or less, the mean CCI at 1 lhr was 17,570 +/- 7003/cu mm, n . 55. When the RAGT index was 2.0 or greater, the mean CCI was 4237 +/- 4100/cu mm, n . 34. At 20 hr when the RAGT index was 1.9 or less, the mean CCI was 8722 +/- 3143/cu mm, n . 33, and when the index was 2.0 or greater, the mean CCI was 571 +/- 1286/cu mm, n . 23. Using this technique, one false negative resulted. Nine positive crossmatches with good increments at 1 hr were found; at 20 hr, however, the survival of these units was zero. These data suggest that this method is a useful adjunct in the selection of platelets in the refractory patient

  5. Testing Testing Testing.

    Science.gov (United States)

    Deville, Craig; O'Neill, Thomas; Wright, Benjamin D.; Woodcock, Richard W.; Munoz-Sandoval, Ana; Gershon, Richard C.; Bergstrom, Betty

    1998-01-01

    Articles in this special section consider (1) flow in test taking (Craig Deville); (2) testwiseness (Thomas O'Neill); (3) test length (Benjamin Wright); (4) cross-language test equating (Richard W. Woodcock and Ana Munoz-Sandoval); (5) computer-assisted testing and testwiseness (Richard Gershon and Betty Bergstrom); and (6) Web-enhanced testing…

  6. Polytechnic Developments. Coombe Lodge Report, Study Conference 74/11.

    Science.gov (United States)

    Further Education Staff Coll., Blagdon (England).

    Papers on new developments in vocational-technical education in Britain include: the polytechnic, its academic board and organizational structure (J.V. Pepper, M. Emerson); the development of polytechnic courses: an analysis of the steps to be taken within the school to begin a new course (J.A. Sandbach); course validation and approval: the…

  7. College Government. Coombe Lodge Report, Collection of Papers.

    Science.gov (United States)

    Further Education Staff Coll., Blagdon (England).

    Five papers examine various facets of the new administrative structures of continuing education in England since 1970. Papers include: the chief administrative officer as college secretary (R.J. Stephens); the chief administrative officer and the academic board (A.M. Davis); the department head and the academic board (H.D. Law); decisionmaking and…

  8. Franchising in Post-16 Education. Coombe Lodge Report.

    Science.gov (United States)

    Evans, Geraldine; And Others

    1991-01-01

    This document contains eight papers in which the principals of eight U.S. and British postsecondary institutions describe the franchising negotiations and arrangements into which their schools have entered. Franchising arrangements at a wide variety of postsecondary institutions are discussed, including community colleges, polytechnics, further…

  9. Numerical modeling of the simulated gas hydrate production test at Mallik 2L-38 in the pilot scale pressure reservoir LARS - Applying the "foamy oil" model

    Science.gov (United States)

    Abendroth, Sven; Thaler, Jan; Klump, Jens; Schicks, Judith; Uddin, Mafiz

    2014-05-01

    In the context of the German joint project SUGAR (Submarine Gas Hydrate Reservoirs: exploration, extraction and transport) we conducted a series of experiments in the LArge Reservoir Simulator (LARS) at the German Research Centre of Geosciences Potsdam. These experiments allow us to investigate the formation and dissociation of hydrates at large scale laboratory conditions. We performed an experiment similar to the field-test conditions of the production test in the Mallik gas hydrate field (Mallik 2L-38) in the Beaufort Mackenzie Delta of the Canadian Arctic. The aim of this experiment was to study the transport behavior of fluids in gas hydrate reservoirs during depressurization (see also Heeschen et al. and Priegnitz et al., this volume). The experimental results from LARS are used to provide details about processes inside the pressure vessel, to validate the models through history matching, and to feed back into the design of future experiments. In experiments in LARS the amount of methane produced from gas hydrates was much lower than expected. Previously published models predict a methane production rate higher than the one observed in experiments and field studies (Uddin et al. 2010; Wright et al. 2011). The authors of the aforementioned studies point out that the current modeling approach overestimates the gas production rate when modeling gas production by depressurization. They suggest that trapping of gas bubbles inside the porous medium is responsible for the reduced gas production rate. They point out that this behavior of multi-phase flow is not well explained by a "residual oil" model, but rather resembles a "foamy oil" model. Our study applies Uddin's (2010) "foamy oil" model and combines it with history matches of our experiments in LARS. Our results indicate a better agreement between experimental and model results when using the "foamy oil" model instead of conventional models of gas flow in water. References Uddin M., Wright J.F. and Coombe D

  10. Evaluating eosin-5-maleimide binding as a diagnostic test for hereditary spherocytosis in newborn infants.

    Science.gov (United States)

    Christensen, R D; Agarwal, A M; Nussenzveig, R H; Heikal, N; Liew, M A; Yaish, H M

    2015-05-01

    Neonates with undiagnosed hereditary spherocytosis (HS) are at risk for developing hazardous hyperbilirubinemia and anemia. Making an early diagnosis of HS in a neonate can prompt anticipatory guidance to prevent these adverse outcomes. A recent comparison study showed that a relatively new diagnostic test for HS, eosin-5-maleimide (EMA)-flow cytometry, performs better than other available tests in confirming HS. However, reports have not specifically examined the performance of this test among neonates. We compared EMA-flow cytometry from blood samples of healthy control neonates vs samples from neonates suspected of having HS on the basis of severe Coombs-negative jaundice and spherocytes on blood film. The diagnosis of HS was later either confirmed or excluded based on clinical findings and next generation sequencing (NGS) after which we correlated the EMA-flow results with the diagnosis. EMA-flow was performed on the blood of 31 neonates; 20 healthy term newborns and 11 who were suspected of having HS. Eight of the 11 were later confirmed positive for HS and one was confirmed positive for hereditary elliptocytosis (HE). All nine had persistently abnormal erythroid morphology, reticulocytosis and anemia, and eight of the nine had relevant mutations discovered using NGS. The other was confirmed positive for HS on the basis that a parent had HS, and the neonate's spherocytosis, reticulocytosis and anemia persisted. The 20 healthy controls and the 2 in whom HS was initially suspected but later excluded all had EMA-flow results in the range reported in healthy children and adults. In contrast, all nine in whom HS or HE was confirmed had abnormal EMA-flow results consistent with previous reports in older children and adults with HS. Although our sample size is small, our findings are consistent with the literature in older children and adults suggesting that EMA-flow cytometric testing performs well in supporting the diagnosis of HS/HE during the early neonatal

  11. Test Architecture, Test Retrofit

    Science.gov (United States)

    Fulcher, Glenn; Davidson, Fred

    2009-01-01

    Just like buildings, tests are designed and built for specific purposes, people, and uses. However, both buildings and tests grow and change over time as the needs of their users change. Sometimes, they are also both used for purposes other than those intended in the original designs. This paper explores architecture as a metaphor for language…

  12. Diagnóstico laboratorial da anemia hemolítica auto-imune: características do teste manual direto do PolybreneÒ Laboratory diagnosis of auto-immune hemolytic anemia: characteristics of the manual direct test of PolybreneTM

    Directory of Open Access Journals (Sweden)

    G.W. Braga

    1998-03-01

    Full Text Available O teste manual direto do PolybreneÒ (TDP e o teste de Coombs direto (TCD foram utilizados para a detecção de IgG na superfície de hemácias de pacientes com diagnóstico clínico e laboratorial de anemia hemolítica auto-imune (AHAI. OBJETIVO: Comparar a sensibilidade e especificidade do TPD e do TCD no diagnóstico da AHAI. MÉTODO: Foram estudados 18 pacientes com diagnóstico clínico-laboratorial de AHAI. Como indivíduos controles, foram testados 20 doadores de sangue assintomáticos e 20 pacientes com anemia falciforme. RESULTADOS: O TCD foi positivo em 14 pacientes e negativo em quatro indivíduos, enquanto o TDP foi positivo em 17 pacientes e negativo em um indivíduo que apresentava TCD positivo devido a fixação de complemento (C3d nas hemácias. Todos os eluatos positivos realizados com a técnica de diclorometano revelaram anticorpos quentes com especificidade "anti-Rh". A sensibilidade do TDP (94% para detectar fixação de IgG in vivo foi significantemente maior (pThe direct manual PolybreneTM test (DPT and the direct antiglobulin tests (DAT were employed to detect antibody sensitizing red blood cell (RCB in patients with clinical and laboratorial findings of autoimmune hemolytic anemia (AIHA. PURPOSE: To compare the sensitivity and specificity of DPT and DAT in the diagnosis of AIHA. METHODS: Eighteen consecutive patients with diagnosis of AIHA were evaluated. The control group consisted of 20 normal volunteers blood donors and 20 patients with sickle cell anemia. All patients and controls were submitted to DPT and DAT. All DAT positive samples were further tested using monospecific reagents ( anti-IgG heavy chain and anti-C3d. Positive samples for either DPT or DAT were evaluated by eluate technique using. The dichloromethane (DCM. RESULTS: The DAT was positive in 14 patients and negative in 4 subjects, while the DPT was positive in 17 patients and negative in 1 individual who had a positive DAT owing to complement (C3d. All

  13. Testing Significance Testing

    Directory of Open Access Journals (Sweden)

    Joachim I. Krueger

    2018-04-01

    Full Text Available The practice of Significance Testing (ST remains widespread in psychological science despite continual criticism of its flaws and abuses. Using simulation experiments, we address four concerns about ST and for two of these we compare ST’s performance with prominent alternatives. We find the following: First, the 'p' values delivered by ST predict the posterior probability of the tested hypothesis well under many research conditions. Second, low 'p' values support inductive inferences because they are most likely to occur when the tested hypothesis is false. Third, 'p' values track likelihood ratios without raising the uncertainties of relative inference. Fourth, 'p' values predict the replicability of research findings better than confidence intervals do. Given these results, we conclude that 'p' values may be used judiciously as a heuristic tool for inductive inference. Yet, 'p' values cannot bear the full burden of inference. We encourage researchers to be flexible in their selection and use of statistical methods.

  14. Using the sense of coherence framework as a tactical approach to communicating corrective action in crisis situations

    OpenAIRE

    Simonsen, Daniel Morten; Jacobsen, Johan Martin Hjorth

    2013-01-01

    By combining attribution theory with crisis types, Coombs developed a theory of Situational Crisis Communication (SCCT) that recommends which crisis response strategy is appropriate for which crisis (Coombs, 1999; 2007; 2012). The seven response strategies presented in SCCT have been tested empirically; however, there still is a need for empirical contributions on the tactical level where the Crisis Communication Message (CCM) is developed, as argued here: “SCCT tries to answer the question o...

  15. Using the sense of coherence framework as a tactical approach to communicating corrective action in crisis situations

    DEFF Research Database (Denmark)

    Simonsen, Daniel Morten; Jacobsen, Johan Martin Hjorth

    By combining attribution theory with crisis types, Coombs developed a theory of Situational Crisis Communication (SCCT) that recommends which crisis response strategy is appropriate for which crisis (Coombs, 1999; 2007; 2012). The seven response strategies presented in SCCT have been tested...... empirically; however, there still is a need for empirical contributions on the tactical level where the Crisis Communication Message (CCM) is developed, as argued here: “SCCT tries to answer the question of when to use different crisis responses, but it does not help researchers address the question of how...... the response strategy named corrective action for our study. According to Coombs, corrective action means giving stakeholders information about a crisis and explaining what is being done to handle it (Coombs, 2012: 150). Corrective action shows stakeholders that their safety is a priority, and thus reduces...

  16. Seismic testing

    International Nuclear Information System (INIS)

    Sollogoub, Pierre

    2001-01-01

    This lecture deals with: qualification methods for seismic testing; objectives of seismic testing; seismic testing standards including examples; main content of standard; testing means; and some important elements of seismic testing

  17. Schirmer test

    Science.gov (United States)

    Tear test; Tearing test; Dry eye test; Basal secretion test; Sjögren - Schirmer; Schirmer's test ... used when the eye doctor suspects you have dry eye. Symptoms include dryness of the eyes or excessive ...

  18. Pinworm test

    Science.gov (United States)

    Oxyuriasis test; Enterobiasis test; Tape test ... diagnose this infection is to do a tape test. The best time to do this is in ... lay their eggs at night. Steps for the test are: Firmly press the sticky side of a ...

  19. Ultrasonic Testing

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyeong Jun; Kuk, Jeong Han

    2002-02-15

    This book introduces ultrasonic testing, which tells of outline of ultrasonic testing, principle of ultrasonic testing, prosperities of ultrasonic waves, radiographic test and ultrasonic test, basic theory on ultrasonic testing, mode conversion, transmission and diffraction, ultrasonic flaw detection and probe, standard test piece and reference test piece, like KS(JIS) ASME and ASTM, classification and properties of ultrasonic testing, straight beam method, angle beam method, ASME SEC.V.Art.5 ASTMA 388 and KS B 0817 Korean industrial standard.

  20. Trichomonas Testing

    Science.gov (United States)

    ... Genetic Tests for Targeted Cancer Therapy Glucose Tests Gonorrhea Testing Gram Stain Growth Hormone Haptoglobin hCG Pregnancy ... With some NAATs, samples collected for testing of gonorrhea and chlamydial infections can also be used to ...

  1. Ham test

    Science.gov (United States)

    Acid hemolysin test; Paroxysmal nocturnal hemoglobinuria - Ham test; PNH - Ham test ... BJ. In: Chernecky CC, Berger BJ, eds. Laboratory Tests and Diagnostic Procedures . 6th ed. Philadelphia, PA: Elsevier ...

  2. Magnesium Test

    Science.gov (United States)

    ... PF4 Antibody Hepatitis A Testing Hepatitis B Testing Hepatitis C Testing HER2/neu Herpes Testing High-sensitivity C-reactive Protein (hs-CRP) Histamine Histone Antibody HIV Antibody and HIV Antigen (p24) HIV Antiretroviral Drug Resistance Testing, Genotypic HIV Viral Load HLA Testing HLA- ...

  3. Lipase Test

    Science.gov (United States)

    ... PF4 Antibody Hepatitis A Testing Hepatitis B Testing Hepatitis C Testing HER2/neu Herpes Testing High-sensitivity C-reactive Protein (hs-CRP) Histamine Histone Antibody HIV Antibody and HIV Antigen (p24) HIV Antiretroviral Drug Resistance Testing, Genotypic HIV Viral Load HLA Testing HLA- ...

  4. Rubella Test

    Science.gov (United States)

    ... PF4 Antibody Hepatitis A Testing Hepatitis B Testing Hepatitis C Testing HER2/neu Herpes Testing High-sensitivity C-reactive Protein (hs-CRP) Histamine Histone Antibody HIV Antibody and HIV Antigen (p24) HIV Antiretroviral Drug Resistance Testing, Genotypic HIV Viral Load HLA Testing HLA- ...

  5. Mono Test

    Science.gov (United States)

    ... PF4 Antibody Hepatitis A Testing Hepatitis B Testing Hepatitis C Testing HER2/neu Herpes Testing High-sensitivity C-reactive Protein (hs-CRP) Histamine Histone Antibody HIV Antibody and HIV Antigen (p24) HIV Antiretroviral Drug Resistance Testing, Genotypic HIV Viral Load HLA Testing HLA- ...

  6. AMA Test

    Science.gov (United States)

    ... PF4 Antibody Hepatitis A Testing Hepatitis B Testing Hepatitis C Testing HER2/neu Herpes Testing High-sensitivity C-reactive Protein (hs-CRP) Histamine Histone Antibody HIV Antibody and HIV Antigen (p24) HIV Antiretroviral Drug Resistance Testing, Genotypic HIV Viral Load HLA Testing HLA- ...

  7. Learner Flexibility Profiles. Coombe Lodge Working Paper. Information Bank Number 1612.

    Science.gov (United States)

    Latcham, J.; Spencer, D. C.

    To help in the exploration of developments in increasing learning flexibility in Great Britain's further education system, this paper suggests the development of learner flexibility profiles as devices for analyzing and recording the nature and extent of student choice or discretion. The introductory section reviews developments in open learning…

  8. Learning Materials for Open Learning in Further Education. Coombe Lodge Working Paper. Information Bank Number 1606.

    Science.gov (United States)

    Latcham, J.

    Arguing that extensive efforts to produce open learning materials should not be undertaken until the possibility of using or adapting existing materials is considered, this paper identifies current sources of materials available in Great Britain for non-advanced further education. The first sections of the paper review common types of open…

  9. Flexistudy: A Development at Barnet College. Coombe Lodge Case Study. Information Bank Number 1351.

    Science.gov (United States)

    Albrecht, A.; Spencer, D. C.

    An outline is presented of Barnet College's flexistudy program, a system for providing a wider range of learning opportunities through a more flexible arrangement of course times and content to students who are unable to attend college regularly, who are too few in number to form a specialist class, or who wish to start school at some time other…

  10. Negotiating the Curriculum. Tutors and Students. Coombe Lodge Working Paper. Information Bank Number 1968.

    Science.gov (United States)

    Brace, Diane

    This working paper presents guidelines for negotiating learning contracts between tutors and postsecondary students enrolled in a vocational program. The first two sections discuss the general rationale for negotiating curricula and the specific benefits of conducting such negotiations with students over the age of 16. Addressed next is the…

  11. An American System of Staff Appraisal. Coombe Lodge Case Study. Information Bank Number 1017.

    Science.gov (United States)

    Latcham, J.

    Prepared for staff in the British further education system, this report describes and explains the formal staff assessment model used at Richland College, Texas. Introductory material describes the college, its student body, and its organization and structure. Next, the four components of the teacher evaluation system used in the Dallas Community…

  12. Coombe Island Extension, Density, and Calcification Data for 1822 to 1987

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Extension, Density, and Calcification data from 35 Porites coral cores covering the entire length of the Great Barrier Reef, Australia. Data set contains 35...

  13. Timothy Coombs: kriise tekib maailmas üha enam / intervjueerinud Kristel Abel

    Index Scriptorium Estoniae

    Coombs, Timothy

    2013-01-01

    Intervjuu riski- ja kriisikommunikatsiooni tippspetsialisti dr W. Timothy Coombsiga, kes räägib kriisikommunikatsiooni hetkeseisust ning jagab nõu, kuidas kriisikommunikatsiooniga toime tulla. Ta on välja arendanud situatsiooni kriisikommunikatsiooni teooria

  14. Matrix Management Structures in Higher Education. Coombe Lodge Working Paper. Information Bank Number 1394.

    Science.gov (United States)

    Cuthbert, Rob

    The matrix structure as an alternative to the departmental structure for colleges and universities is discussed, and the matrix system at Middlesex Polytechnic in England is used as illustration. The major impact of the introduction of a matrix structure is its effect on teaching activities within the institution. The matrix structure formally…

  15. Selection through Interviewing: Entrance Procedures in Teacher Recruitment. Coombe Lodge Research Report. Information Bank Number 1837.

    Science.gov (United States)

    Theodossin, Ernest

    This study looks briefly at work done in the field of teacher selection. It then examines the interviewing arrangements at Balls Park College (Australia) in 1970-71, when candidates were being selected for the teacher training course which began in October 1971. An attempt is made to discern relationships existing among: (1) the data available to…

  16. Neuropathy Tests

    Science.gov (United States)

    ... LD) Lactoferrin Lactose Tolerance Tests LDL Cholesterol LDL Particle Testing (LDL-P) Lead Legionella Testing Leptin Levetiracetam Lipase ... tests, such as computed tomography (CT) scans or magnetic resonance imaging ... suspected, additional testing may be performed to evaluate heart rate, blood ...

  17. Pharmacogenomic Testing

    Science.gov (United States)

    ... your family Plan for the future Insurance and financial planning Transition for children Emergency preparedness Testing & Services Testing ... Support Genetic Disease Information Find a Support Group Financial Planning Who Should I Tell? Genetic Testing & Counseling Compensation ...

  18. Predictive Testing

    Science.gov (United States)

    ... your family Plan for the future Insurance and financial planning Transition for children Emergency preparedness Testing & Services Testing ... Support Genetic Disease Information Find a Support Group Financial Planning Who Should I Tell? Genetic Testing & Counseling Compensation ...

  19. Syphilis Test

    Science.gov (United States)

    ... Genetic Tests for Targeted Cancer Therapy Glucose Tests Gonorrhea Testing Gram Stain Growth Hormone Haptoglobin hCG Pregnancy ... treated for another sexually transmitted disease , such as gonorrhea Is pregnant, during the first prenatal visit and ...

  20. Randomization tests

    CERN Document Server

    Edgington, Eugene

    2007-01-01

    Statistical Tests That Do Not Require Random Sampling Randomization Tests Numerical Examples Randomization Tests and Nonrandom Samples The Prevalence of Nonrandom Samples in Experiments The Irrelevance of Random Samples for the Typical Experiment Generalizing from Nonrandom Samples Intelligibility Respect for the Validity of Randomization Tests Versatility Practicality Precursors of Randomization Tests Other Applications of Permutation Tests Questions and Exercises Notes References Randomized Experiments Unique Benefits of Experiments Experimentation without Mani

  1. Test chamber

    NARCIS (Netherlands)

    Leferink, Frank Bernardus Johannes

    2009-01-01

    A test chamber for measuring electromagnetic radiation emitted by an apparatus to be tested or for exposing an apparatus to be tested to an electromagnetic radiation field. The test chamber includes a reverberation chamber made of a conductive tent fabric. To create a statistically uniform field in

  2. Tensile testing

    CERN Document Server

    2004-01-01

    A complete guide to the uniaxial tensile test, the cornerstone test for determining the mechanical properties of materials: Learn ways to predict material behavior through tensile testing. Learn how to test metals, alloys, composites, ceramics, and plastics to determine strength, ductility and elastic/plastic deformation. A must for laboratory managers, technicians, materials and design engineers, and students involved with uniaxial tensile testing. Tensile Testing , Second Edition begins with an introduction and overview of the test, with clear explanations of how materials properties are determined from test results. Subsequent sections illustrate how knowledge gained through tensile tests, such as tension properties to predict the behavior (including strength, ductility, elastic or plastic deformation, tensile and yield strengths) have resulted in improvements in materals applications. The Second Edition is completely revised and updated. It includes expanded coverage throughout the volume on a variety of ...

  3. Test quality

    International Nuclear Information System (INIS)

    Hartley, R.S.; Keller, A.E.

    1992-01-01

    Inservice testing of safety-related components at nuclear power plants is performed under the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (the Code). Subsections IWP and IWV of Section 11 of the Code state test method and frequency requirements for pumps and valves, respectively. Tests vary greatly in quality and frequency. This paper explores the concept of test quality and its relationship with operational readiness and preventive maintenance. This paper also considers the frequencies of component testing. Test quality is related to a test's ability to detect degradation that can cause component failure. The quality of the test depends on several factors, including specific parameters measured, system or component conditions, and instrument accuracy. The quality of some currently required tests for check valves, motor-operated valves, and pumps is also discussed. Suggestions are made to improve test quality by measuring different parameters, testing valves under load, and testing positive displacement pumps at high pressure and centrifugal pumps at high flow rate conditions. These suggestions can help to improve the level of assurance of component operational readiness gained from testing

  4. Test quality

    International Nuclear Information System (INIS)

    Hartley, R.S.; Keller, A.E.

    1992-01-01

    This document discusses inservice testing of safety-related components at nuclear power plants which is performed under the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (the Code). Subsections IWP and IWV of Section XI of the Code state test method and frequency requirements for pumps and valves respectively. Tests vary greatly in quality and frequency. This paper explores the concept of test quality and its relationship with operational readiness and preventive maintenance. This paper also considers the frequencies of component testing. Test quality is related to a test's ability to detect degradation that can cause component failure. The quality of the test depends on several factors, including specific parameters measured, system or component conditions, and instrument accuracy. The quality of some currently required tests for check valves, motor-operated valves, and pumps is also discussed. Suggestions are made to improve test quality by measuring different parameters, testing valves under load, and testing positive displacement pumps at high pressure and centrifugal pumps at high flow rate conditions. These suggestions can help to improve the level of assurance of component operational readiness gained from testing

  5. Randomization tests

    National Research Council Canada - National Science Library

    Edgington, Eugene S

    1980-01-01

    .... This book provides all the necessary theory and practical guidelines, such as instructions for writing computer programs, to permit experimenters to transform any statistical test into a distribution-free test...

  6. Laboratory Tests

    Science.gov (United States)

    ... Medical Devices Radiation-Emitting Products Vaccines, Blood & Biologics Animal & ... What are lab tests? Laboratory tests are medical devices that are intended for use on samples of blood, urine, or other tissues ...

  7. Triglycerides Test

    Science.gov (United States)

    ... K. Brunner & Suddarth's Handbook of Laboratory and Diagnostic Tests. 2 nd Ed, Kindle. Philadelphia: Wolters Kluwer Health, Lippincott Williams & Wilkins; c2014. Triglycerides; 491–2 p. Lab Tests ...

  8. Lactate Test

    Science.gov (United States)

    ... Plasma Free Metanephrines Platelet Count Platelet Function Tests Pleural Fluid Analysis PML-RARA Porphyrin Tests Potassium Prealbumin ... ency/article/000391.htm . (2002 January, Updated). Lactate (Liquid) Reagent Set. Pointe Scientific, Inc. [On-line Reagent ...

  9. Electrolytes Test

    Science.gov (United States)

    ... Plasma Free Metanephrines Platelet Count Platelet Function Tests Pleural Fluid Analysis PML-RARA Porphyrin Tests Potassium Prealbumin ... of potassium is found in the plasma , the liquid portion of the blood. Monitoring potassium is important ...

  10. Ferritin Test

    Science.gov (United States)

    ... normal" values. By comparing your test results with reference values, you and your healthcare provider can see if ... along with other iron tests , when a routine complete blood count (CBC) shows that a person's hemoglobin and hematocrit ...

  11. Cholesterol Test

    Science.gov (United States)

    ... artery disease. Other names for a cholesterol test: Lipid profile, Lipid panel What is it used for? If you ... Clinic [Internet]. Mayo Foundation for Medical Education and Research; c1998-2017.Cholesterol Test: Overview; 2016 Jan 12 [ ...

  12. Gonorrhea Test

    Science.gov (United States)

    ... Links Patient Resources For Health Professionals Subscribe Search Gonorrhea Testing Send Us Your Feedback Choose Topic At ... Sources Ask Us Also Known As GC Test Gonorrhea NAAT or NAT Neisseria gonorrhoeae Nucleic Acid Amplification ...

  13. Susceptibility Testing

    Science.gov (United States)

    ... Marker Bicarbonate (Total CO2) Bilirubin Blood Culture Blood Gases Blood Ketones Blood Smear Blood Typing Blood Urea ... hours depending on the method used. There are commercial tests available that offer rapid susceptibility testing and ...

  14. Nationale test

    DEFF Research Database (Denmark)

    2009-01-01

    Professor Sven Erik Nordenbo og centerleder Niels Egelund, begge DPU, i samtale om nationale test.......Professor Sven Erik Nordenbo og centerleder Niels Egelund, begge DPU, i samtale om nationale test....

  15. Nationale Test

    DEFF Research Database (Denmark)

    2009-01-01

    Hvad er egentlig formålet med de nationale test? Bliver eleverne klogere af at blive testet? Og er der en sammenhæng mellem bandekrig og nationale test? Fysisk medie: dpu.dk/tv......Hvad er egentlig formålet med de nationale test? Bliver eleverne klogere af at blive testet? Og er der en sammenhæng mellem bandekrig og nationale test? Fysisk medie: dpu.dk/tv...

  16. VDRL test

    Science.gov (United States)

    ... confirmed with another blood test to make the diagnosis of syphilis. Normal value ranges may vary slightly among different ... broken) Alternative Names Venereal disease research ... laboratory test (VDRL) – serum. In: Chernecky CC, Berger BJ, eds. Laboratory Tests and Diagnostic Procedures . 6th ed. St Louis, MO: Elsevier Saunders; ...

  17. Drug Testing

    Science.gov (United States)

    ... testing, substance abuse testing, toxicology screen, tox screen, sports doping tests What is it used for? Drug screening is used to find out whether or not a person has taken a certain drug or drugs. It ... Sports organizations. Professional and collegiate athletes usually need to ...

  18. HIV Testing

    Science.gov (United States)

    ... Abroad Treatment Basic Statistics Get Tested Find an HIV testing site near you. Enter ZIP code or city Follow HIV/AIDS CDC HIV CDC HIV/AIDS See RSS | ... All Collapse All Should I get tested for HIV? CDC recommends that everyone between the ages of ...

  19. Nondestructive Testing

    Energy Technology Data Exchange (ETDEWEB)

    Berger, Harold [Argonne National Laboratory

    1969-01-01

    A nondestructive test is an examination of an object in any manner which will not impair the future usefulness of the object. This booklet discusses a few basic methods of nondestructive testing, and some of their characteristics. In addition, it discusses possible future methods for nondestructive testing by taking a quick look at some of the methods now under study.

  20. Ultrasonic testing

    Energy Technology Data Exchange (ETDEWEB)

    Song, Sung Jin [Sungkwunkwan Univ., Seoul (Korea, Republic of); Jeong, Hyun Jo [Wonkwang Univ., Iksan (Korea, Republic of)

    2004-02-15

    For the proper performance of ultrasonic testing of steel welded joints, and anisotropic material it is necessary to have sound understanding on the underlying physics. To provide such an understanding, it is beneficial to have simulation tools for ultrasonic testing. In order to address such a need, we develop effective approaches to simulate angle beam ultrasonic testing with a personal computer. The simulation is performed using ultrasonic measurement models based on the computationally efficient multi-Gaussian beams. This reach will describe the developed ultrasonic testing models together with the experimental verification of their accuracy.

  1. Troponins Test

    Science.gov (United States)

    ... lab's website in order to provide you with background information about the test(s) you had performed. You will need to return ... C, Banfi G, Guidi GC. Influence of a half-marathon run on NT-proBNP and troponin ... MedlinePlus Medical Encyclopedia [On-line information]. Available online ...

  2. Insulin Test

    Science.gov (United States)

    ... hours before blood is collected, but occasionally a health practitioner may do testing when fasting is not possible, such as when a glucose tolerance test (see Glucose ) is done. In some cases, the health practitioner may request that a person fast longer ...

  3. Genetic Testing

    Science.gov (United States)

    ... is often the only way to determine if symptoms could possibly be related to celiac disease. For a person who faces this situation, a negative gene test would indicate that symptoms are not the result of celiac disease. A positive gene test, however, does not diagnose ...

  4. Potassium test

    Science.gov (United States)

    ... hyperkalemia ) may be due to: Addison disease (rare) Blood transfusion Certain medicines Crushed tissue injury Hyperkalemic periodic paralysis ... released. This may cause a falsely high result. Alternative Names Hypokalemia test; K+ Images Blood test References Mount DB. Disorders of potassium balance. ...

  5. Nationale test

    DEFF Research Database (Denmark)

    Bundsgaard, Jeppe; Puck, Morten Rasmus

    Nationale test skubber undervisning i en forkert retning. Det er lærerne og skolelederne enige om. Men særligt skolelederne ser også muligheder for at bruge testen til at få viden om elevernes faglige kompetencer og om undervisningen. Det kommer til udtryk i rapporten Nationale test: Danske lærere...

  6. Oedometer Tests

    DEFF Research Database (Denmark)

    Thorsen, Grete

    1996-01-01

    The paper describes the results of oedometer tests carried out with samples from Eemian fresh-water deposits and the methods used to determine the preconsolidation pressure from the test results. The influence of creep in the material on the apparent preconsolidation pressure is estimated from...

  7. TORCH Test

    Science.gov (United States)

    ... Parietal Cell Antibody Partial Thromboplastin Time (PTT, aPTT) Parvovirus B19 Pericardial Fluid Analysis Peritoneal Fluid Analysis Pertussis Tests ... enterovirus, Epstein-Barr virus , varicella-zoster virus , and parvovirus B19 . How is the sample collected for testing? A ...

  8. Automating Test Activities: Test Cases Creation, Test Execution, and Test Reporting with Multiple Test Automation Tools

    OpenAIRE

    Loke Mun Sei

    2015-01-01

    Software testing has become a mandatory process in assuring the software product quality. Hence, test management is needed in order to manage the test activities conducted in the software test life cycle. This paper discusses on the challenges faced in the software test life cycle, and how the test processes and test activities, mainly on test cases creation, test execution, and test reporting is being managed and automated using several test automation tools, i.e. Jira, ...

  9. Trypsinogen test

    Science.gov (United States)

    ... care provider about the meaning of your specific test results. What Abnormal Results ... vary in size, so it may be harder to get a blood sample from one person than another. Other risks associated with having ...

  10. Just testing

    International Nuclear Information System (INIS)

    Robinson, D.

    1985-01-01

    In the 1950s, most of the men who witnessed Britain's nuclear tests at Christmas Island in the Pacific were national servicemen, aged 19 or 20. Some revelled in sun and swimming, some were bored, some were too busy to be bored. How many of the twenty thousand servicemen involved in the tests suspected that they might be exposed to radiation that would reveal itself a generation later in blood and bone cancers, sterility, cataracts, or deformities in their children. The Ministry of Defence insists nobody was in danger. This book tells a different story, in the words of the servicemen, and of their medical reports, about secrets which are no longer Official. It is important not only to the victims of a government's extraordinary reluctance to face up to the tragic consequences of a programme of nuclear tests on Christmas Island and in Australia, but to anyone concerned with the damage that nuclear testing is still doing in the world today. (author)

  11. Test Ship

    Data.gov (United States)

    Federal Laboratory Consortium — The U. S. Navy dedicated the decommissioned Spruance Class destroyer ex-PAUL F. FOSTER (EDD 964), Test Ship, primarily for at sea demonstration of short range weapon...

  12. Injection Tests

    CERN Document Server

    Kain, V

    2009-01-01

    The success of the start-up of the LHC on 10th of September was in part due to the preparation without beam and injection tests in 2008. The injection tests allowed debugging and improvement in appropriate portions to allow safe, efficient and state-of-the-art commissioning later on. The usefulness of such an approach for a successful start-up becomes obvious when looking at the problems we encountered before and during the injection tests and could solve during this period. The outline of the preparation and highlights of the different injection tests will be presented and the excellent performance of many tools discussed. A list of shortcomings will follow, leading to some planning for the preparation of the run in 2009.

  13. Fungal Tests

    Science.gov (United States)

    ... Wu, A. (2006). Tietz Clinical Guide to Laboratory Tests, Fourth Edition. Saunders Elsevier, St. Louis, Missouri. Pp 1569, 1570, 1532, 1616. Forbes, B. et. al. (© 2007). Bailey & Scott's Diagnostic Microbiology, Twelfth Edition: Mosby Elsevier Press, St. Louis, Missouri. ...

  14. PTH Test

    Science.gov (United States)

    ... Gregory C. Sephel PhD FACB MT(ASCP). Lab Tests Online adjunct board member. Director Clinical Pathology, VA TN Valley Healthcare System; Associate Professor Pathology, Microbiology, Immunology, Vanderbilt University School of Medicine. Sources Used ...

  15. Phosphorus Test

    Science.gov (United States)

    ... be seen with increased intake of the mineral, hypocalcemia , and with kidney dysfunction. Someone with a mild ... usually detected because of the relationship with and effect on calcium levels . Calcium is routinely tested as ...

  16. Procalcitonin Test

    Science.gov (United States)

    ... normal" values. By comparing your test results with reference values, you and your healthcare provider can see if ... g., blood culture , urine culture ), lactate , blood gases , complete blood count (CBC) , and cerebrospinal fluid (CSF) analysis . When is ...

  17. RSV Test

    Science.gov (United States)

    ... Sex Hormone Binding Globulin (SHBG) Shiga toxin-producing Escherichia coli Sickle Cell Tests Sirolimus Smooth Muscle Antibody (SMA) ... University Medical Center, LAB Letter [On-line newsletter]. PDF available for download at http://www.stanfordhospital.com/ ...

  18. Prenatal Tests

    Science.gov (United States)

    ... tests are considered routine — that is, almost all pregnant women receiving prenatal care get them. They include things like checking urine (pee) levels for protein, sugar, or signs of infection. Other non-routine ...

  19. Progesterone Test

    Science.gov (United States)

    ... replacement therapy, or help diagnose the cause of abnormal uterine bleeding When To Get Tested? At specific times during ... receiving progesterone replacement therapy; when a woman has abnormal uterine bleeding Sample Required? A blood sample drawn from a ...

  20. Testosterone Test

    Science.gov (United States)

    ... Testing Triglycerides Troponin Tryptase Tumor Markers Uric Acid Urinalysis Urine Albumin and Albumin/Creatinine Ratio Urine Culture ... 2010) 2536–259. Centers for Disease Control Hormone Standardization website(HoST). Available online at http://www.cdc. ...

  1. Pertussis Tests

    Science.gov (United States)

    ... of Conditions Not Listed? Not Listed? Acidosis and Alkalosis Adrenal Insufficiency and Addison Disease Alcoholism Allergies Alzheimer ... tested? Pertussis, commonly called whooping cough, is a respiratory infection caused by the bacteria Bordetella pertussis . These ...

  2. Tests computarizados

    Directory of Open Access Journals (Sweden)

    R. Fernando Prialé Z.

    1983-12-01

    Full Text Available En primer lugar, se considera el impacto de las microcomputadoras en la actualidad, viéndolo como un hecho social destinado a traer profundos cambios: nos orientamos hacia una cultura informática cuyo signo es la posibilidad de tratar grandes cantidades de información. En segundo lugar; se analiza brevemente la importancia de los tests en el desarrollo de la psicología. Finalmente, se discute la posibilidad de aplicar la informática a la psicometría con el ejemplo del test de BARSIT.   The impact of microcomputers is discussed as a cultural fact that will bring profound changes in the near future: a society with an ubiquous capacity for treating big amounts of information. The importance of tests for the development of psychology is then analysed. Finaly, the possibility of applying microcomputers to psychometry is discussed trough a concrete example: The BARSIT test.

  3. VMA Test

    Science.gov (United States)

    ... spasms and rapid eye movements referred to as "dancing eyes, dancing feet." The VMA test may also be ordered ... a pheochromocytoma or neuroblastoma? People with a family history of multiple endocrine neoplasia (MEN2), a genetic condition ...

  4. Neuropsychological testing.

    Science.gov (United States)

    Zucchella, Chiara; Federico, Angela; Martini, Alice; Tinazzi, Michele; Bartolo, Michelangelo; Tamburin, Stefano

    2018-06-01

    Neuropsychological testing is a key diagnostic tool for assessing people with dementia and mild cognitive impairment, but can also help in other neurological conditions such as Parkinson's disease, stroke, multiple sclerosis, traumatic brain injury and epilepsy. While cognitive screening tests offer gross information, detailed neuropsychological evaluation can provide data on different cognitive domains (visuospatial function, memory, attention, executive function, language and praxis) as well as neuropsychiatric and behavioural features. We should regard neuropsychological testing as an extension of the neurological examination applied to higher order cortical function, since each cognitive domain has an anatomical substrate. Ideally, neurologists should discuss the indications and results of neuropsychological assessment with a clinical neuropsychologist. This paper summarises the rationale, indications, main features, most common tests and pitfalls in neuropsychological evaluation. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  5. Testing theories

    International Nuclear Information System (INIS)

    Casten, R F

    2015-01-01

    This paper discusses some simple issues that arise in testing models, with a focus on models for low energy nuclear structure. By way of simplified examples, we illustrate some dangers in blind statistical assessments, pointing out especially the need to include theoretical uncertainties, the danger of over-weighting precise or physically redundant experimental results, the need to assess competing theories with independent and physically sensitive observables, and the value of statistical tests properly evaluated. (paper)

  6. Simulating the gas hydrate production test at Mallik using the pilot scale pressure reservoir LARS

    Science.gov (United States)

    Heeschen, Katja; Spangenberg, Erik; Schicks, Judith M.; Priegnitz, Mike; Giese, Ronny; Luzi-Helbing, Manja

    2014-05-01

    hydrate dissociation applying the foamy oil approach, a method earlier adopted to model the Mallik production test (see abstract Abendroth et al., this volume). Combined with a dense set of data from a cylindrical electrical resistance tomography (ERT) array (see abstract Priegnitz et al., this volume), very valuable information were gained on the spatial as well as temporal formation and dissociation of gas hydrates as well as changes in permeability and resulting pathways for the fluid flow. Here we present the set-up and execution of the experiment and discuss the results from temperature and flow measurements with respect to the gas hydrate dissociation and characteristics of resulting fluid flow. Uddin, M., Wright, F., and Coombe, D. 2011. Numerical Study of Gas Evolution and Transport Behaviours in Natural Gas-Hydrate Reservoirs. Journal of Canadian Petroleum Technology 50, 70-89.

  7. Allergy testing - skin

    Science.gov (United States)

    Patch tests - allergy; Scratch tests - allergy; Skin tests - allergy; RAST test; Allergic rhinitis - allergy testing; Asthma - allergy testing; Eczema - allergy testing; Hayfever - allergy testing; Dermatitis - allergy testing; Allergy testing; ...

  8. Adaptive test

    DEFF Research Database (Denmark)

    Kjeldsen, Lars Peter; Eriksen, Mette Rose

    2010-01-01

    Artikelen er en evaluering af de adaptive tests, som blev indført i folkeskolen. Artiklen sætter særligt fokus på evaluering i folkeskolen, herunder bidrager den med vejledning til evaluering, evalueringsværktøjer og fagspecifkt evalueringsmateriale.......Artikelen er en evaluering af de adaptive tests, som blev indført i folkeskolen. Artiklen sætter særligt fokus på evaluering i folkeskolen, herunder bidrager den med vejledning til evaluering, evalueringsværktøjer og fagspecifkt evalueringsmateriale....

  9. Tests computarizados

    OpenAIRE

    Prialé Z., R. Fernando

    1983-01-01

    En primer lugar, se considera el impacto de las microcomputadoras en la actualidad, viéndolo como un hecho social destinado a traer profundos cambios: nos orientamos hacia una cultura informática cuyo signo es la posibilidad de tratar grandes cantidades de información. En segundo lugar; se analiza brevemente la importancia de los tests en el desarrollo de la psicología. Finalmente, se discute la posibilidad de aplicar la informática a la psicometría con el ejemplo del test de BARSIT.   The im...

  10. Testing Hubbert

    International Nuclear Information System (INIS)

    Brandt, Adam R.

    2007-01-01

    The Hubbert theory of oil depletion, which states that oil production in large regions follows a bell-shaped curve over time, has been cited as a method to predict the future of global oil production. However, the assumptions of the Hubbert method have never been rigorously tested with a large, publicly available data set. In this paper, three assumptions of the modern Hubbert theory are tested using data from 139 oil producing regions. These regions are sub-national (United States state-level, United States regional-level), national, and multi-national (subcontinental and continental) in scale. We test the assumption that oil production follows a bell-shaped curve by generating best-fitting curves for each region using six models and comparing the quality of fit across models. We also test the assumptions that production over time in a region tends to be symmetric, and that production is more bell-shaped in larger regions than in smaller regions

  11. Prealbumin Test

    Science.gov (United States)

    ... T. J. (© 2007). Mosby's Diagnostic and Laboratory Test Reference 8th Edition: Mosby, Inc., Saint Louis, MO. Pp 755-756. Clarke, W. and Dufour, D. R., Editors (© 2006). Contemporary Practice in Clinical Chemistry: AACC Press, Washington, DC. Pp 197. Banh, L. ( ...

  12. Genomic Testing

    Science.gov (United States)

    ... this database. Top of Page Evaluation of Genomic Applications in Practice and Prevention (EGAPP™) In 2004, the Centers for Disease Control and Prevention launched the EGAPP initiative to establish and test a ... and other applications of genomic technology that are in transition from ...

  13. Fibrinogen Test

    Science.gov (United States)

    ... thrombotic episode ) As a follow-up to an abnormal bleeding disorder test ( prothrombin time, PT or partial thromboplastin time, ... to help diagnose disseminated intravascular coagulation (DIC) or abnormal ... status of a progressive disease (such as liver disease ) over time or, rarely, ...

  14. (stress) testing

    African Journals Online (AJOL)

    However, maximal HR was significantly higher in all groups during their sporting activities than during stress testing in the laboratory (P < 0.01). Conclusions. Maximal HR in veteran athletes during specific sporting activities was significantly higher than that attained during a routine sECG. This finding was not sport-specific, ...

  15. Trypsinogen Test

    Science.gov (United States)

    ... exocrine.html. UPCMD (1998 – 2002). Cystic Fibrosis. University Pathology Consortium, LLC [On-line information]. Available online at http://www.upcmd.com/dot/examples/00218/description.html. Sainato, D., (2002, March). Genetic Testing for CF Going Mainstream? Clinical Laboratory ...

  16. Chymotrypsin Test

    Science.gov (United States)

    ... exocrine.html. UPCMD (1998 – 2002). Cystic Fibrosis. University Pathology Consortium, LLC [On-line information]. Available online at http://www.upcmd.com/dot/examples/00218/description.html. Sainato, D., (2002, March). Genetic Testing for CF Going Mainstream? Clinical Laboratory ...

  17. Radiographic Test

    Energy Technology Data Exchange (ETDEWEB)

    Lee, H.J; Yang, S.H. [Korea Electric Power Research Institute, Taejon (Korea)

    2002-07-01

    This report contains theory, procedure technique and interpretation of radiographic examination and written for whom preparing radiographic test Level II. To determine this baseline of technical competence in the examination, the individual must demonstrate a knowledge of radiography physics, radiation safety, technique development, radiation detection and measurement, facility design, and the characteristics of radiation-producing devices and their principles of operation. (author) 98 figs., 23 tabs.

  18. Testing Understanding and Understanding Testing.

    Science.gov (United States)

    Pedersen, Jean; Ross, Peter

    1985-01-01

    Provides examples in which graphs are used in the statements of problems or in their solutions as a means of testing understanding of mathematical concepts. Examples (appropriate for a beginning course in calculus and analytic geometry) include slopes of lines and curves, quadratic formula, properties of the definite integral, and others. (JN)

  19. Credibility test; Vertrauens-Test

    Energy Technology Data Exchange (ETDEWEB)

    Fuhs, Michael

    2009-07-01

    Solar wafer producers must prove their quality standards. Q-Cells has started a marketing office and opened their test center to journalists. They are aware that adherence to standards is going only half the way of quality assurance. The other half consists in gaining the customers' trust. (orig.)

  20. Knowledge Test

    DEFF Research Database (Denmark)

    Sørensen, Ole Henning

    1998-01-01

    The knowledge test is about competing temporal and spatial expressions of the politics of technological development and national prosperity in contemporary society. The discussion is based on literature of national systems of innovation and industrial networks of various sorts. Similarities...... and differences in the disparate theories are discussed through a critical perspective on metaphor, time, space, agency and technology. It is asserted that the process of globalization is leading to a new production of space-time perceptions and practices where localization and globalization is becoming...... increasingly important. National space is being contested and nation states need to perform differently....

  1. Testing SUSY

    CERN Document Server

    Cassel, S; Ross, G G

    2010-01-01

    If SUSY provides a solution to the hierarchy problem then supersymmetric states should not be too heavy. This requirement is quantified by the Barbieri-Giudice fine tuning measure that provides a quantitative test of SUSY as a solution to the hierarchy problem. The measure is useful in correlating the impact of the various experimental measurements relevant to the search for supersymmetry and also in identifying the most sensitive measurements for testing SUSY. In this paper we apply the measure to the CMSSM, computing it to two-loop order and taking account of current experimental limits and the constraint on dark matter abundance. Using this we determine the present limits on the CMSSM parameter space and identify the measurements at the LHC that are most significant in covering the remaining parameter space. Without imposing the LEP Higgs mass bound we show that the smallest fine tuning (1:14.5) consistent with a saturation of the relic density within the 1$\\sigma$ WMAP bounds corresponds to a Higgs mass o...

  2. Thrombotic Thrombocytopenic Purpura

    Science.gov (United States)

    ... creatinine (kre-AT-ih-neen) level may be high. Creatinine is a blood product that's normally removed by the kidneys. Coombs Test This blood test is used to find out whether TTP is the cause of hemolytic anemia . For this test, a sample ...

  3. Auto-immune Haemolytic Anaemia and Paroxys

    African Journals Online (AJOL)

    who presented with an acute auto-immune haemolytic anaemia. In addition to a persistently positive Coombs test, with specific red cell auto-antibodies, the acidified serum test and the sucrose haemolysis test were repeatedly positive. CASE REPORT. A 24-year-old Indian woman was admitted to hospital in. July 1969.

  4. Heart failure - tests

    Science.gov (United States)

    CHF - tests; Congestive heart failure - tests; Cardiomyopathy - tests; HF - tests ... the best test to: Identify which type of heart failure (systolic, diastolic, valvular) Monitor your heart failure and ...

  5. Nuclear stress test

    Science.gov (United States)

    ... Persantine stress test; Thallium stress test; Stress test - nuclear; Adenosine stress test; Regadenoson stress test; CAD - nuclear stress; Coronary artery disease - nuclear stress; Angina - nuclear ...

  6. Bacterial bioluminescence response to long-term exposure to reverse osmosis treated effluents from dye industries

    Digital Repository Service at National Institute of Oceanography (India)

    Ravindran, J.; Manikandan, B.; Shirodkar, P.V.; Francis, K.X.; ManiMurali, R.; Vethamony, P.

    essential and important in view of environmental pollution. Analysis of these effluents using physical and chemical methods is insufficient due to their complex nature and they may not reflect the biological effects (Coombe et al. 1999). In-vivo tests....K., and Duffy, L.K. 2007. Effects of total dissolved solids on aquatic organism: A review of literature and recommendation for salmonid species. Am. J Environ. Sci. 3: 1-6. 3. Coombe, V.T., Moore, K.W., and Hutchings, M.J. 1999. TIE and TRE: An abbreviated...

  7. The Current Provision for Further and Higher Education in Wales. Coombe Lodge Working Paper. Information Bank Number 1627.

    Science.gov (United States)

    Marsh, D. T.

    Provision for postsecondary higher education in Wales, the nature of the Welsh system, and future concerns are discussed. The roles of the Welsh Office and the Welsh Joint Education Committee contrast greatly with central organizations in England. There is one university in Wales, comprising seven constituent colleges. Additional institutions in…

  8. Computer-Based Testing: Test Site Security.

    Science.gov (United States)

    Rosen, Gerald A.

    Computer-based testing places great burdens on all involved parties to ensure test security. A task analysis of test site security might identify the areas of protecting the test, protecting the data, and protecting the environment as essential issues in test security. Protecting the test involves transmission of the examinations, identifying the…

  9. Mononucleosis spot test

    Science.gov (United States)

    Monospot test; Heterophile antibody test; Heterophile agglutination test; Paul-Bunnell test; Forssman antibody test ... The mononucleosis spot test is done when symptoms of mononucleosis are ... Fatigue Fever Large spleen (possibly) Sore throat Tender ...

  10. Coccidioides precipitin test

    Science.gov (United States)

    Coccidioidomycosis antibody test; Coccidioides blood test; Valley fever blood test ... There is no special preparation for the test. ... The precipitin test is one of several tests that can be done to determine if you are infected with coccidioides, which ...

  11. Myoglobin urine test

    Science.gov (United States)

    Urine myoglobin; Heart attack - myoglobin urine test; Myositis - myoglobin urine test; Rhabdomyolysis - myoglobin urine test ... The test involves only normal urination, which should cause no discomfort.

  12. Underground Nuclear Testing Program, Nevada Test Site

    International Nuclear Information System (INIS)

    1975-09-01

    The Energy Research and Development Administration (ERDA) continues to conduct an underground nuclear testing program which includes tests for nuclear weapons development and other tests for development of nuclear explosives and methods for their application for peaceful uses. ERDA also continues to provide nuclear explosive and test site support for nuclear effects tests sponsored by the Department of Defense. This Supplement extends the Environmental Statement (WASH-1526) to cover all underground nuclear tests and preparations for tests of one megaton (1 MT) or less at the Nevada Test Site (NTS) during Fiscal Year 1976. The test activities covered include numerous continuing programs, both nuclear and non-nuclear, which can best be conducted in a remote area. However, if nuclear excavation tests or tests of yields above 1 MT or tests away from NTS should be planned, these will be covered by separate environmental statements

  13. Test Review: TestDaF

    Science.gov (United States)

    Norris, John; Drackert, Anastasia

    2018-01-01

    The Test of German as a Foreign Language (TestDaF) plays a critical role as a standardized test of German language proficiency. Developed and administered by the Society for Academic Study Preparation and Test Development (g.a.s.t.), TestDaF was launched in 2001 and has experienced persistent annual growth, with more than 44,000 test takers in…

  14. Tests Related to Pregnancy

    Science.gov (United States)

    ... to learn. Search form Search Tests related to pregnancy You are here Home Testing & Services Testing for ... to Genetic Counseling . What Are Tests Related to Pregnancy? Pregnancy related testing is done before or during ...

  15. Brucellosis in childhood in the Western Cape | Hendricks | South ...

    African Journals Online (AJOL)

    The diagnosis was made on the basis of a positive serological titre (> 1:160) for Brucella abortus. The prozone phenomenon was encountered in 6 cases; however, the Coombs test confirmed the diagnosis in these cases. Children under 7 years were treated with co-trimoxazole and rifampicin and those over 7 years with ...

  16. Rebound hyperbilirubinaemia in neonates admitted to Mofid ...

    African Journals Online (AJOL)

    term neonates without a positive Coombs test were included, and only 1 patient was readmitted with rebound hyperbilirubinaemia. (this was thought to be due to breastmilk jaundice). Our ndings are therefore similar to those of Del Vecchio et al.,[8] who reported that 1 in 48 newborns required readmission for phototherapy.

  17. Leukemoid reaction, a rare manifestation of autoimmune hemolytic anemia in a case of small duct primary sclerosing cholangitis.

    Science.gov (United States)

    Salagre, Kaustubh D; Sahay, Ravindra Nath; Patil, Anuja; Pati, Anuja; Joshi, Amita; Shukla, Akash

    2013-10-01

    A 48 year old lady presented with jaundice and exertional breathlesness. Her laboratory reports showed anaemia, reticulocytosis, leucocytosis, elevated Lactate Dehydrogenase (LDH), alkaline phosphatase levels, hyperbillirubinemia and positive direct Coomb's test. After ruling out all the other causes of autoimmunity and hemolytic anemia, she was diagnosed as leukemoid reaction due to autoimmune hemolytic anemia with primary sclerosing cholangitis. Patient showed immediate improvement after corticosteroids.

  18. TREATMENT OF SEVERE PARKINSONISM WITH L-DOPA*

    African Journals Online (AJOL)

    1971-05-08

    May 8, 1971 ... rent research has given hope of providing more effective drug therapy. ... tion of dopamine in patients with parkinsonism as com- pared with normal ... count, blood urea, Coombs and liver function tests were carried out in each ...

  19. Design Driven Testing Test Smarter, Not Harder

    CERN Document Server

    Stephens, M

    2010-01-01

    The groundbreaking book Design Driven Testing brings sanity back to the software development process by flipping around the concept of Test Driven Development (TDD) - restoring the concept of using testing to verify a design instead of pretending that unit tests are a replacement for design. Anyone who feels that TDD is "Too Damn Difficult" will appreciate this book. Design Driven Testing shows that, by combining a forward-thinking development process with cutting-edge automation, testing can be a finely targeted, business-driven, rewarding effort. In other words, you'll learn how to test

  20. Learning software testing with Test Studio

    CERN Document Server

    Madi, Rawane

    2013-01-01

    Learning Software Testing with Test Studio is a practical, hands-on guide that will help you get started with Test Studio to design your automated solution and tests. All through the book, there are best practices and tips and tricks inside Test Studio which can be employed to improve your solution just like an experienced QA.If you are a beginner or a professional QA who is seeking a fast, clear, and direct to the point start in automated software testing inside Test Studio, this book is for you. You should be familiar with the .NET framework, mainly Visual Studio, C#, and SQL, as the book's

  1. Engine Test Facility (ETF)

    Data.gov (United States)

    Federal Laboratory Consortium — The Air Force Arnold Engineering Development Center's Engine Test Facility (ETF) test cells are used for development and evaluation testing of propulsion systems for...

  2. Optimizing the educational subject between testing and inclusion in an era of neoliberalism

    DEFF Research Database (Denmark)

    Hamre, Bjørn Frithiof; Morin, Anne; Ydesen, Christian

    2018-01-01

    In 1960, Philip H. Coombs (1915-2006), who was programme director for education at the Ford Foundation and head of the US delegation to the Organisation for European Economic Cooperation (OEEC), wrote: ‘[There is] a potential conflict between education’s obligation to promote the growth and freedom...... of the individual for its own sake and the necessity to serve the growth and security of society as a whole’. The quote stems from an OEEC publication on how to redesign education to better accommodate economic growth, improve education planning in light of the Cold War, and improve national educational data...... for the purpose of comparing Western education systems (OEEC, 1960). The quote eloquently sums up a fundamental schism regarding the very purpose of education that is not the least reflected in a political and professional tug of war over what education is and should be: Should education be a production factor...

  3. Thyroid Function Tests

    Science.gov (United States)

    ... Home » Thyroid Function Tests Leer en Español Thyroid Function Tests FUNCTION HOW DOES THE THYROID GLAND FUNCTION? ... Cancer Thyroid Nodules in Children and Adolescents Thyroid Function Tests Resources Thyroid Function Tests Brochure PDF En ...

  4. CEA (Carcinoembryonic Antigen) Test

    Science.gov (United States)

    ... Gene Mutations Testing Cytomegalovirus (CMV) Tests D-dimer Dengue Fever Testing Des-gamma-carboxy prothrombin (DCP) DHEAS ... Glance Why Get Tested? Primarily to monitor cancer treatment, including response to therapy and recurrence; as an ...

  5. Blood Test: Bilirubin

    Science.gov (United States)

    ... Videos for Educators Search English Español Blood Test: Bilirubin KidsHealth / For Parents / Blood Test: Bilirubin What's in ... liver or kidneys) is working. What Is a Bilirubin Test? A bilirubin test measures how much bilirubin ...

  6. Catecholamine blood test

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003561.htm Catecholamine blood test To use the sharing features on this page, ... measured with a urine test than with a blood test. How the Test is Performed A blood sample ...

  7. Anthrax blood test

    Science.gov (United States)

    Anthrax serology test; Antibody test for anthrax; Serologic test for B. anthracis ... This test may be performed when the health care provider suspects you have anthrax infection. The bacteria that cause ...

  8. Myoglobin blood test

    Science.gov (United States)

    Serum myoglobin; Heart attack - myoglobin blood test; Myositis - myoglobin blood test; Rhabdomyolysis - myoglobin blood test ... too high, it can damage the kidneys. This test is ordered when your health care provider suspects ...

  9. Blood sugar test

    Science.gov (United States)

    ... sugar; Blood sugar level; Fasting blood sugar; Glucose test; Diabetic screening - blood sugar test; Diabetes - blood sugar test ... The test may be done in the following ways: After you have not eaten anything for at least 8 ...

  10. Ketones urine test

    Science.gov (United States)

    Ketone bodies - urine; Urine ketones; Ketoacidosis - urine ketones test; Diabetic ketoacidosis - urine ketones test ... Urine ketones are usually measured as a "spot test." This is available in a test kit that ...

  11. Lactose tolerance tests

    Science.gov (United States)

    Hydrogen breath test for lactose tolerance ... Two common methods include: Lactose tolerance blood test Hydrogen breath test The hydrogen breath test is the preferred method. It measures the amount of hydrogen ...

  12. Test techniques for fracture mechanics testing

    International Nuclear Information System (INIS)

    Schwalbe, K.H.

    1980-01-01

    Test methods for fracture mechanics tests are described. Two groups of techniques are distinguished: Those for measurement of stable crack growth and those for determination of the loading parameters. (orig.) [de

  13. To test or not to test

    DEFF Research Database (Denmark)

    Rochon, Justine; Gondan, Matthias; Kieser, Meinhard

    2012-01-01

    Background: Student's two-sample t test is generally used for comparing the means of two independent samples, for example, two treatment arms. Under the null hypothesis, the t test assumes that the two samples arise from the same normally distributed population with unknown variance. Adequate...... control of the Type I error requires that the normality assumption holds, which is often examined by means of a preliminary Shapiro-Wilk test. The following two-stage procedure is widely accepted: If the preliminary test for normality is not significant, the t test is used; if the preliminary test rejects...... the null hypothesis of normality, a nonparametric test is applied in the main analysis. Methods: Equally sized samples were drawn from exponential, uniform, and normal distributions. The two-sample t test was conducted if either both samples (Strategy I) or the collapsed set of residuals from both samples...

  14. Materials testing 1985

    International Nuclear Information System (INIS)

    1985-01-01

    The following subjects were dealt with at the meeting: Testing with vibration loads; Hardness testing; Calibration of test devices and equipment; Test technique for compound materials; Vibration strength testing and expense of experiments; Solving problems in introducing forces into samples and components and process of ambulant materials testing. There are 17 separate abstracts from among 43 lectures. (orig./PW) [de

  15. 5-HIAA Test

    Science.gov (United States)

    ... PF4 Antibody Hepatitis A Testing Hepatitis B Testing Hepatitis C Testing HER2/neu Herpes Testing High-sensitivity C-reactive Protein (hs-CRP) Histamine Histone Antibody HIV Antibody and HIV Antigen (p24) HIV Antiretroviral Drug Resistance Testing, Genotypic HIV Viral Load HLA Testing HLA- ...

  16. Uric Acid Test

    Science.gov (United States)

    ... PF4 Antibody Hepatitis A Testing Hepatitis B Testing Hepatitis C Testing HER2/neu Herpes Testing High-sensitivity C-reactive Protein (hs-CRP) Histamine Histone Antibody HIV Antibody and HIV Antigen (p24) HIV Antiretroviral Drug Resistance Testing, Genotypic HIV Viral Load HLA Testing HLA- ...

  17. Direct Antiglobulin Test

    Science.gov (United States)

    ... PF4 Antibody Hepatitis A Testing Hepatitis B Testing Hepatitis C Testing HER2/neu Herpes Testing High-sensitivity C-reactive Protein (hs-CRP) Histamine Histone Antibody HIV Antibody and HIV Antigen (p24) HIV Antiretroviral Drug Resistance Testing, Genotypic HIV Viral Load HLA Testing HLA- ...

  18. CK-MB Test

    Science.gov (United States)

    ... PF4 Antibody Hepatitis A Testing Hepatitis B Testing Hepatitis C Testing HER2/neu Herpes Testing High-sensitivity C-reactive Protein (hs-CRP) Histamine Histone Antibody HIV Antibody and HIV Antigen (p24) HIV Antiretroviral Drug Resistance Testing, Genotypic HIV Viral Load HLA Testing HLA- ...

  19. Understanding Your Tests

    Science.gov (United States)

    ... PF4 Antibody Hepatitis A Testing Hepatitis B Testing Hepatitis C Testing HER2/neu Herpes Testing High-sensitivity C-reactive Protein (hs-CRP) Histamine Histone Antibody HIV Antibody and HIV Antigen (p24) HIV Antiretroviral Drug Resistance Testing, Genotypic HIV Viral Load HLA Testing HLA- ...

  20. Myasthenia Gravis Tests

    Science.gov (United States)

    ... PF4 Antibody Hepatitis A Testing Hepatitis B Testing Hepatitis C Testing HER2/neu Herpes Testing High-sensitivity C-reactive Protein (hs-CRP) Histamine Histone Antibody HIV Antibody and HIV Antigen (p24) HIV Antiretroviral Drug Resistance Testing, Genotypic HIV Viral Load HLA Testing HLA- ...

  1. Citric acid urine test

    Science.gov (United States)

    Urine - citric acid test; Renal tubular acidosis - citric acid test; Kidney stones - citric acid test; Urolithiasis - citric acid test ... No special preparation is necessary for this test. But the results ... test is usually done while you are on a normal diet. Ask your ...

  2. From Test Takers to Test Makers

    Science.gov (United States)

    Smith, Kari

    2009-01-01

    As a classroom teacher, Kari Smith realized that traditional objective tests don't always assess what students actually know. But tests are so deeply embedded in the education system that it would be difficult to do away with them entirely. Smith decided to make tests into learning tools. In this article, Smith describes three strategies for…

  3. CANFLEX fuel bundle strength tests (test report)

    International Nuclear Information System (INIS)

    Chang, Seok Kyu; Chung, C. H.; Kim, B. D.

    1997-08-01

    This document outlines the test results for the strength tests of the CANFLEX fuel bundle. Strength tests are performed to determine and verify the amount of the bundle shape distortion which is against the side-stops when the bundles are refuelling. There are two cases of strength test; one is the double side-stop test which simulates the normal bundle refuelling and the other is the single side-stop test which simulates the abnormal refuelling. the strength test specification requires that the fuel bundle against the side-stop(s) simulators for this test were fabricated and the flow rates were controlled to provide the required conservative hydraulic forces. The test rig conditions of 120 deg C, 11.2 MPa were retained for 15 minutes after the flow rate was controlled during the test in two cases, respectively. The bundle loading angles of number 13- number 15 among the 15 bundles were 67.5 deg CCW and others were loaded randomly. After the tests, the bundle shapes against the side-stops were measured and inspected carefully. The important test procedures and measurements were discussed as follows. (author). 5 refs., 22 tabs., 5 figs

  4. Test design requirements: Thermal conductivity probe testing

    International Nuclear Information System (INIS)

    Heath, R.E.

    1985-01-01

    This document establishes the test design requirements for development of a thermal conductivity probe test. The thermal conductivity probe determines in situ thermal conductivity using a line source transient heat conduction analysis. This document presents the rationale for thermal conductivity measurement using a thermal conductivity probe. A general test description is included. Support requirements along with design constraints are detailed to allow simple design of the thermal conductivity probe and test. The schedule and delivery requirements of the responsible test designer are also included. 7 refs., 1 fig

  5. Irradiation effects test series test IE-1 test results report

    International Nuclear Information System (INIS)

    Quapp, W.J.; Allison, C.M.; Farrar, L.C.; Mehner, A.S.

    1977-03-01

    The report describes the results of the first programmatic test in the Nuclear Regulatory Commission Irradiation Effects Test Series. This test (IE-1) used four 0.97m long PWR-type fuel rods fabricated from previously irradiated Saxton fuel. The objectives of this test were to evaluate the effect of fuel pellet density on pellet-cladding interaction during a power ramp and to evaluate the influence of the irradiated state of the fuel and cladding on rod behavior during film boiling operation. Data are presented on the behavior of irradiated fuel rods during steady-state operation, a power ramp, and film boiling operation. The effects of as-fabricated gap size, as-fabricated fuel density, rod power, and power ramp rate on pellet-cladding interaction are discussed. Test data are compared with FRAP-T2 computer model predictions, and comments on the consequences of sustained film boiling operation on irradiated fuel rod behavior are provided

  6. The Stimulus test stand

    International Nuclear Information System (INIS)

    Christofek, L.; Rapidis, P.; Reinhard, A.; Fermilab

    2005-01-01

    The Stimulus Test Stand was originally constructed and assembled for testing the SVX2 ASIC readout and then upgraded for SVX3 ASIC prototyping and testing. We have modified this system for SVX4 ASIC [1] prototype testing. We described the individual components below. Additional details for other hardware for SVX4 testing can be found in reference [2]. We provide a description of the Stimulus Test Stand used for prototype testing of the SVX4 chip

  7. CSF-VDRL test

    Science.gov (United States)

    ... test - CSF; Neurosyphilis - VDRL Images CSF test for syphilis References Chernecky CC, Berger BJ. Venereal disease research laboratory test (VDRL), test, cerebrospinal fluid – specimen. In: Chernecky CC, Berger BJ, eds. Laboratory Tests and Diagnostic Procedures . 6th ed. St Louis, MO: Elsevier Saunders; ...

  8. CO2 blood test

    Science.gov (United States)

    Bicarbonate test; HCO3-; Carbon dioxide test; TCO2; Total CO2; CO2 test - serum; Acidosis - CO2; Alkalosis - CO2 ... Many medicines can interfere with blood test results. Your health ... need to stop taking any medicines before you have this test. DO ...

  9. Tonopah Test Range - Index

    Science.gov (United States)

    Capabilities Test Operations Center Test Director Range Control Track Control Communications Tracking Radars Photos Header Facebook Twitter YouTube Flickr RSS Tonopah Test Range Top TTR_TOC Tonopah is the testing range of choice for all national security missions. Tonopah Test Range (TTR) provides research and

  10. Rail Impact Testing. Test Operations Procedure (TOP)

    Science.gov (United States)

    2008-09-15

    impact test. The rail impact test is used to verify structural integrity of the test item and the adequacy of the tie-down system and tie-down...strength of provisions, connection and supporting structural frame, paragraph 5.2.3 ** Superscript...parts, to include outriggers and booms) without advanced approval by SDDCTEA. Torque nuts on wire rope clips to their correct value. Torque cable

  11. Tractor accelerated test on test rig

    Directory of Open Access Journals (Sweden)

    M. Mattetti

    2013-09-01

    Full Text Available The experimental tests performed to validate a tractor prototype before its production, need a substantial financial and time commitment. The tests could be reduced using accelerated tests able to reproduce on the structural part of the tractor, the same damage produced on the tractor during real life in a reduced time. These tests were usually performed reproducing a particular harsh condition a defined number of times, as for example using a bumpy road on track to carry out the test in any weather condition. Using these procedures the loads applied on the tractor structure are different with respect to those obtained during the real use, with the risk to apply loads hard to find in reality. Recently it has been demonstrated how, using the methodologies designed for cars, it is possible to also expedite the structural tests for tractors. In particular, automotive proving grounds were recently successfully used with tractors to perform accelerated structural tests able to reproduce the real use of the machine with an acceleration factor higher than that obtained with the traditional methods. However, the acceleration factor obtained with a tractor on proving grounds is in any case reduced due to the reduced speed of the tractors with respect to cars. In this context, the goal of the paper is to show the development of a methodology to perform an accelerated structural test on a medium power tractor using a 4 post test rig. In particular, several proving ground testing conditions have been performed to measure the loads on the tractor. The loads obtained were then edited to remove the not damaging portion of signals, and finally the loads obtained were reproduced in a 4 post test rig. The methodology proposed could be a valid alternative to the use of a proving ground to reproduce accelerated structural tests on tractors.

  12. Color vision test

    Science.gov (United States)

    ... present from birth) color vision problems: Achromatopsia -- complete color blindness , seeing only shades of gray Deuteranopia -- difficulty telling ... Vision test - color; Ishihara color vision test Images Color blindness tests References Bowling B. Hereditary fundus dystrophies. In: ...

  13. Kidney function tests

    Science.gov (United States)

    Kidney function tests are common lab tests used to evaluate how well the kidneys are working. Such tests include: ... Oh MS, Briefel G. Evaluation of renal function, water, electrolytes ... and Management by Laboratory Methods . 23rd ed. Philadelphia, ...

  14. Liver Function Tests

    Science.gov (United States)

    ... digest food, store energy, and remove poisons. Liver function tests are blood tests that check to see ... as hepatitis and cirrhosis. You may have liver function tests as part of a regular checkup. Or ...

  15. Home blood sugar testing

    Science.gov (United States)

    Diabetes - home glucose testing; Diabetes - home blood sugar testing ... Usual times to test your blood sugar are before meals and at bedtime. Your provider may ask you to check your blood sugar 2 hours after a meal or ...

  16. Teratology testing under REACH.

    Science.gov (United States)

    Barton, Steve

    2013-01-01

    REACH guidelines may require teratology testing for new and existing chemicals. This chapter discusses procedures to assess the need for teratology testing and the conduct and interpretation of teratology tests where required.

  17. Celiac Disease Tests

    Science.gov (United States)

    ... diet When To Get Tested? When you have symptoms suggesting celiac disease, such as chronic diarrhea, abdominal pain, anemia , and ... Celiac tests are usually ordered for people with symptoms suggesting celiac disease, including anemia and abdominal pain. Sometimes celiac testing ...

  18. Aviation Flight Test

    Data.gov (United States)

    Federal Laboratory Consortium — Redstone Test Center provides an expert workforce and technologically advanced test equipment to conduct the rigorous testing necessary for U.S. Army acquisition and...

  19. Mark 1 Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Mark I Test Facility is a state-of-the-art space environment simulation test chamber for full-scale space systems testing. A $1.5M dollar upgrade in fiscal year...

  20. Growth hormone suppression test

    Science.gov (United States)

    ... Acromegaly - blood test; Gigantism - blood test Images Blood test References Kaiser U, Ho KKY. Pituitary physiology and diagnostic evaluation. In: Melmed S, Polonsky KS, Larsen PR, Kronenberg HM, eds. Williams Textbook of Endocrinology . 13th ed. Philadelphia, PA: Elsevier; ...

  1. Lactose Tolerance Tests

    Science.gov (United States)

    ... Plasma Free Metanephrines Platelet Count Platelet Function Tests Pleural Fluid Analysis PML-RARA Porphyrin Tests Potassium Prealbumin ... of these, the person tested is given a liquid to drink that contains a standard amount of ...

  2. Thyroid Diseases Tests

    Science.gov (United States)

    ... Gene Mutations Testing Cytomegalovirus (CMV) Tests D-dimer Dengue Fever Testing Des-gamma-carboxy prothrombin (DCP) DHEAS ... newborn blood screening programs since early detection and treatment can minimize long-term damage. Hashimoto thyroiditis : the ...

  3. What Is Diagnostic Testing?

    Science.gov (United States)

    ... your family Plan for the future Insurance and financial planning Transition for children Emergency preparedness Testing & Services Testing ... Support Genetic Disease Information Find a Support Group Financial Planning Who Should I Tell? Genetic Testing & Counseling Compensation ...

  4. Tests for H. pylori

    Science.gov (United States)

    ... ulcers and many cases of stomach inflammation (chronic gastritis). How the Test is Performed There are several ... treating bleeding, or making sure there is no cancer. Why the Test is Performed Testing is most ...

  5. BUN - blood test

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003474.htm BUN - blood test To use the sharing features on this page, ... for the Test Many medicines can interfere with blood test results. Your health care provider will tell you ...

  6. Porphyrins - blood test

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003372.htm Porphyrins blood test To use the sharing features on this page, ... blood or the urine . This article discusses the blood test. How the Test is Performed A blood sample ...

  7. Renin blood test

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003698.htm Renin blood test To use the sharing features on this page, ... renin test measures the level of renin in blood. How the Test is Performed A blood sample is needed . How ...

  8. Prolactin blood test

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003718.htm Prolactin blood test To use the sharing features on this page, ... test measures the amount of prolactin in the blood. How the Test is Performed A blood sample is needed . How ...

  9. Large Rotor Test Apparatus

    Data.gov (United States)

    Federal Laboratory Consortium — This test apparatus, when combined with the National Full-Scale Aerodynamics Complex, produces a thorough, full-scale test capability. The Large Rotor Test Apparatus...

  10. Ketones blood test

    Science.gov (United States)

    Acetone bodies; Ketones - serum; Nitroprusside test; Ketone bodies - serum; Ketones - blood; Ketoacidosis - ketones blood test ... fat cells break down in the blood. This test is used to diagnose ketoacidosis . This is a ...

  11. Dexamethasone suppression test

    Science.gov (United States)

    DST; ACTH suppression test; Cortisol suppression test ... During this test, you will receive dexamethasone. This is a strong man-made (synthetic) glucocorticoid medicine. Afterward, your blood is drawn ...

  12. Bone mineral density test

    Science.gov (United States)

    BMD test; Bone density test; Bone densitometry; DEXA scan; DXA; Dual-energy x-ray absorptiometry; p-DEXA; Osteoporosis - BMD ... need to undress. This scan is the best test to predict your risk of fractures, especially of ...

  13. Assessment and Testing.

    Science.gov (United States)

    Clapham, Caroline

    2000-01-01

    Explores the term "applied linguistics" and discusses the role of language testing within this discipline, the relationship between testing and teaching, and the relationship between testing and assessment (Author/VWL)

  14. Tips on Blood Testing

    Science.gov (United States)

    ... Test Pain, Discomfort and Anxiety Tips to Help Children through Their Medical Tests Tips to Help the Elderly through Their Medical Tests Find Us On Social Media: Facebook Twitter Google Plus Footer Menu Home About ...

  15. Blood Test: Testosterone

    Science.gov (United States)

    ... Test: Estradiol Precocious Puberty Understanding Puberty Endocrine System Male Reproductive System Getting a Blood Test (Video) All About Puberty Blood Test (Video) Male Reproductive System View more About Us Contact Us Partners Editorial ...

  16. Structural Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Provides a wide variety of testing equipment, fixtures and facilities to perform both unique aviation component testing as well as common types of materials testing...

  17. SPECT quality control tests

    International Nuclear Information System (INIS)

    Robilotta, C.C.; Rebelo, M.F.S.; Oliveira, M.A.; Abe, R.

    1987-01-01

    Quality control tests of tomographic system composed by a rotatory chamber (CGR Gammatomome T-9000) and a microcomputer are presented. Traditional quality control tests for scintilation chambers and specific tests for tomographic systems are reported. (M.A.C.) [pt

  18. Irradiation effects test Series Scoping Test 1: test results report

    International Nuclear Information System (INIS)

    Quapp, W.J.; Allison, C.M.; Farrar, L.C.

    1977-09-01

    The report describes the results of the first scoping test in the Irradiation Effects Test Series conducted by the Thermal Fuels Behavior Program, which is part of the Water Reactor Research Program of EG and G Idaho, Inc. The research is sponsored by the United States Nuclear Regulatory Commission. This test used an unirradiated, three-foot-long, PWR-type fuel rod. The objective of this test was to thoroughly evaluate the remote fabrication procedures to be used for irradiated rods in future tests, handling plans, and reactor operations. Additionally, selected fuel behavior data were obtained. The fuel rod was subjected to a series of preconditioning power cycles followed by a power increase which brought the fuel rod power to about 20.4 kW/ft peak linear heat rating at a coolant mass flux of 1.83 x 10 6 lb/hr-ft 2 . Film boiling occurred for a period of 4.8 minutes following flow reductions to 9.6 x 10 5 and 7.5 x 10 5 lb/hr-ft 2 . The test fuel rod failed following reactor shutdown as a result of heavy internal and external cladding oxidation and embrittlement which occurred during the film boiling operation

  19. Small test SDHW systems

    DEFF Research Database (Denmark)

    Vejen, Niels Kristian

    1999-01-01

    Three small test SDHW systems was tested in a laboratory test facility.The three SDHW systems where all based on the low flow principe and a mantle tank but the design of the systems where different.......Three small test SDHW systems was tested in a laboratory test facility.The three SDHW systems where all based on the low flow principe and a mantle tank but the design of the systems where different....

  20. Textiles Performance Testing Facilities

    Data.gov (United States)

    Federal Laboratory Consortium — The Textiles Performance Testing Facilities has the capabilities to perform all physical wet and dry performance testing, and visual and instrumental color analysis...

  1. Electromagnetic Interface Testing Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Electromagnetic Interface Testing facilitysupports such testing asEmissions, Field Strength, Mode Stirring, EMP Pulser, 4 Probe Monitoring/Leveling System, and...

  2. FOOD SAFETY TESTING LABORATORY

    Data.gov (United States)

    Federal Laboratory Consortium — This laboratory develops screening assays, tests and modifies biosensor equipment, and optimizes food safety testing protocols for the military and civilian sector...

  3. Thyroxine (T4) Test

    Science.gov (United States)

    ... K. Brunner & Suddarth's Handbook of Laboratory and Diagnostic Tests. 2 nd Ed, Kindle. Philadelphia: Wolters Kluwer Health, Lippincott Williams & Wilkins; c2014. Thryoxine, Serum 485 p. Lab Tests ...

  4. Laboratory for filter testing

    Energy Technology Data Exchange (ETDEWEB)

    Paluch, W.

    1987-07-01

    Filters used for mine draining in brown coal surface mines are tested by the Mine Draining Department of Poltegor. Laboratory tests of new types of filters developed by Poltegor are analyzed. Two types of tests are used: tests of scale filter models and tests of experimental units of new filters. Design and operation of the test stands used for testing mechanical properties and hydraulic properties of filters for coal mines are described: dimensions, pressure fluctuations, hydraulic equipment. Examples of testing large-diameter filters for brown coal mines are discussed.

  5. Mobile Test Capabilities

    Data.gov (United States)

    Federal Laboratory Consortium — The Electrical Power Mobile Test capabilities are utilized to conduct electrical power quality testing on aircraft and helicopters. This capability allows that the...

  6. GPS Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Global Positioning System (GPS) Test Facility Instrumentation Suite (GPSIS) provides great flexibility in testing receivers by providing operational control of...

  7. Hot Ground Vibration Tests

    Data.gov (United States)

    National Aeronautics and Space Administration — Ground vibration tests or modal surveys are routinely conducted to support flutter analysis for subsonic and supersonic vehicles. However, vibration testing...

  8. Test Control Center (TCC)

    Data.gov (United States)

    Federal Laboratory Consortium — The Test Control Center (TCC) provides a consolidated facility for planning, coordinating, controlling, monitoring, and analyzing distributed test events. ,The TCC...

  9. Moisture related test protocols for HVS testing

    CSIR Research Space (South Africa)

    Denneman, E

    2008-10-01

    Full Text Available outcomes of HVS tests where the moisture condition of the pavement or specific layers in the pavement is under investigation for a specific test. Practical guidance is then provided on the potential systems (how to manage the moisture – hardware) as well...

  10. Integrated Test and Evaluation Flight Test 3 Flight Test Plan

    Science.gov (United States)

    Marston, Michael Lawrence

    2015-01-01

    The desire and ability to fly Unmanned Aircraft Systems (UAS) in the National Airspace System (NAS) is of increasing urgency. The application of unmanned aircraft to perform national security, defense, scientific, and emergency management are driving the critical need for less restrictive access by UAS to the NAS. UAS represent a new capability that will provide a variety of services in the government (public) and commercial (civil) aviation sectors. The growth of this potential industry has not yet been realized due to the lack of a common understanding of what is required to safely operate UAS in the NAS. NASA's UAS Integration into the NAS Project is conducting research in the areas of Separation Assurance/Sense and Avoid Interoperability, Human Systems Integration (HSI), and Communication to support reducing the barriers of UAS access to the NAS. This research is broken into two research themes namely, UAS Integration and Test Infrastructure. UAS Integration focuses on airspace integration procedures and performance standards to enable UAS integration in the air transportation system, covering Sense and Avoid (SAA) performance standards, command and control performance standards, and human systems integration. The focus of Test Infrastructure is to enable development and validation of airspace integration procedures and performance standards, including the integrated test and evaluation. In support of the integrated test and evaluation efforts, the Project will develop an adaptable, scalable, and schedulable relevant test environment capable of evaluating concepts and technologies for unmanned aircraft systems to safely operate in the NAS. To accomplish this task, the Project will conduct a series of Human-in-the-Loop and Flight Test activities that integrate key concepts, technologies and/or procedures in a relevant air traffic environment. Each of the integrated events will build on the technical achievements, fidelity and complexity of the previous tests and

  11. Test report for core drilling ignitability testing

    International Nuclear Information System (INIS)

    Witwer, K.S.

    1996-01-01

    Testing was carried out with the cooperation of Westinghouse Hanford Company and the United States Bureau of Mines at the Pittsburgh Research Center in Pennsylvania under the Memorandum of Agreement 14- 09-0050-3666. Several core drilling equipment items, specifically those which can come in contact with flammable gasses while drilling into some waste tanks, were tested under conditions similar to actual field sampling conditions. Rotary drilling against steel and rock as well as drop testing of several different pieces of equipment in a flammable gas environment were the specific items addressed. The test items completed either caused no ignition of the gas mixture, or, after having hardware changes or drilling parameters modified, produced no ignition in repeat testing

  12. Digface characterization test plan (remote testing)

    International Nuclear Information System (INIS)

    Croft, K.; Hyde, R.; Allen, S.

    1993-08-01

    The objective of the Digface Characterization (DFC) Remote Testing project is to remotely deploy a sensor head (Mini-Lab) across a digface to determine if it can characterize the contents below the surface. The purpose of this project is to provide a robotics technology that allows removal of workers from hazards, increases speed of operations, and reduces life cycle costs compared to alternate methods and technologies. The Buried Waste Integrated Demonstration (BWID) is funding the demonstration, testing, and evaluation of DFC. This document describes the test plan for the DFC remote deployment demonstration for the BWID. The purposes of the test plan are to establish test parameters so that the demonstration results are deemed useful and usable and perform the demonstration in a safe manner and within all regulatory requirements

  13. Irradiation effects test series, test IE-5. Test results report

    International Nuclear Information System (INIS)

    Croucher, D.W.; Yackle, T.R.; Allison, C.M.; Ploger, S.A.

    1978-01-01

    Test IE-5, conducted in the Power Burst Facility at the Idaho National Engineering Laboratory, employed three 0.97-m long pressurized water reactor type fuel rods, fabricated from previously irradiated zircaloy-4 cladding and one similar rod fabricated from unirradiated cladding. The objectives of the test were to evaluate the influence of simulated fission products, cladding irradiation damage, and fuel rod internal pressure on pellet-cladding interaction during a power ramp and on fuel rod behavior during film boiling operation. The four rods were subjected to a preconditioning period, a power ramp to an average fuel rod peak power of 65 kW/m, and steady state operation for one hour at a coolant mass flux of 4880 kg/s-m 2 for each rod. After a flow reduction to 1800 kg/s-m 2 , film boiling occurred on one rod. Additional flow reductions to 970 kg/s-m 2 produced film boiling on the three remaining fuel rods. Maximum time in film boiling was 80s. The rod having the highest initial internal pressure (8.3 MPa) failed 10s after the onset of film boiling. A second rod failed about 90s after reactor shutdown. The report contains a description of the experiment, the test conduct, test results, and results from the preliminary postirradiation examination. Calculations using a transient fuel rod behavior code are compared with the test results

  14. Irradiation Effects Test Series: Test IE-3. Test results report

    International Nuclear Information System (INIS)

    Farrar, L.C.; Allison, C.M.; Croucher, D.W.; Ploger, S.A.

    1977-10-01

    The objectives of the test reported were to: (a) determine the behavior of irradiated fuel rods subjected to a rapid power increase during which the possibility of a pellet-cladding mechanical interaction failure is enhanced and (b) determine the behavior of these fuel rods during film boiling following this rapid power increase. Test IE-3 used four 0.97-m long pressurized water reactor type fuel rods fabricated from previously irradiated fuel. The fuel rods were subjected to a preconditioning period, followed by a power ramp to 69 kW/m at a coolant mass flux of 4920 kg/s-m 2 . After a flow reduction to 2120 kg/s-m 2 , film boiling occurred on the fuel rods. One rod failed approximately 45 seconds after the reactor was shut down as a result of cladding embrittlement due to extensive cladding oxidation. Data are presented on the behavior of these irradiated fuel rods during steady-state operation, the power ramp, and film boiling operation. The effects of a power ramp and power ramp rates on pellet-cladding interaction are discussed. Test data are compared with FRAP-T3 computer model calculations and data from a previous Irradiation Effects test in which four irradiated fuel rods of a similar design were tested. Test IE-3 results indicate that the irradiated state of the fuel rods did not significantly affect fuel rod behavior during normal, abnormal (power ramp of 20 kW/m per minute), and accident (film boiling) conditions

  15. Displacement compressors - acceptance tests

    CERN Document Server

    International Organization for Standardization. Geneva

    1996-01-01

    ISO 1217:2009 specifies methods for acceptance tests regarding volume rate of flow and power requirements of displacement compressors. It also specifies methods for testing liquid-ring type compressors and the operating and testing conditions which apply when a full performance test is specified.

  16. Refactoring test code

    NARCIS (Netherlands)

    A. van Deursen (Arie); L.M.F. Moonen (Leon); A. van den Bergh; G. Kok

    2001-01-01

    textabstractTwo key aspects of extreme programming (XP) are unit testing and merciless refactoring. Given the fact that the ideal test code / production code ratio approaches 1:1, it is not surprising that unit tests are being refactored. We found that refactoring test code is different from

  17. Load testing circuit

    DEFF Research Database (Denmark)

    2009-01-01

    A load testing circuit a circuit tests the load impedance of a load connected to an amplifier. The load impedance includes a first terminal and a second terminal, the load testing circuit comprising a signal generator providing a test signal of a defined bandwidth to the first terminal of the load...

  18. SAP crm integration testing

    OpenAIRE

    Černiavskaitė, Marija

    2017-01-01

    This Bachelor's thesis presents SAP CRM and integration systems testing analysis: investigation in SAP CRM and SAP PO systems, presentation of relationship between systems, introduction to third-party system (non-SAP) – Network Informational System (NIS) which has integration with SAP, presentation of best CRM testing practises, analysis and recommendation of integration testing. Practical integration testing is done in accordance to recommendations.

  19. 1968 Prototype Diagnostic Test.

    Science.gov (United States)

    Veterans Administration Hospital, Bedford, MA.

    This true-false diagnostic test was used for pretesting of employees at a Veterans Administration Hospital. The test is comprised of 20 items. An alternate test--Classification Questionnaire--was used for testing after remedial training. (For related document, see TM 002 334.) (DB)

  20. Liquid Rocket Engine Testing

    Science.gov (United States)

    Rahman, Shamim

    2005-01-01

    Comprehensive Liquid Rocket Engine testing is essential to risk reduction for Space Flight. Test capability represents significant national investments in expertise and infrastructure. Historical experience underpins current test capabilities. Test facilities continually seek proactive alignment with national space development goals and objectives including government and commercial sectors.

  1. Nationale test i naturfag

    DEFF Research Database (Denmark)

    Andreasen, Karen Egedal; Jensen, Lars Bang

    2015-01-01

    Kapitlet rummer en analyse og diskussion af test inden for naturfagsområdet og de fagforståelser de afspejler med fokus på de nationale test.......Kapitlet rummer en analyse og diskussion af test inden for naturfagsområdet og de fagforståelser de afspejler med fokus på de nationale test....

  2. Numeracy Tests For Dummies

    CERN Document Server

    Beveridge, Colin

    2012-01-01

    The easy way to get practice and excel at numeracy tests Whether you're looking for a new job, applying to certain university courses, or attempting to join the military, you're increasingly likely to face a numeracy test as part of the screening process. And the only way to prepare for a numeracy test is practise. Numeracy Tests For Dummies is an accessible one-stop guide to pass these test. Featuring expert advice, instruction, review, and plenty of practise, Numeracy Tests For Dummies will help you succeed. Numeracy Tests For Dummies contains instruction and revision on:Basic mathematical k

  3. Dtest Testing Software

    Science.gov (United States)

    Jain, Abhinandan; Cameron, Jonathan M.; Myint, Steven

    2013-01-01

    This software runs a suite of arbitrary software tests spanning various software languages and types of tests (unit level, system level, or file comparison tests). The dtest utility can be set to automate periodic testing of large suites of software, as well as running individual tests. It supports distributing multiple tests over multiple CPU cores, if available. The dtest tool is a utility program (written in Python) that scans through a directory (and its subdirectories) and finds all directories that match a certain pattern and then executes any tests in that directory as described in simple configuration files.

  4. ITER test programme

    International Nuclear Information System (INIS)

    Abdou, M.; Baker, C.; Casini, G.

    1991-01-01

    ITER has been designed to operate in two phases. The first phase which lasts for 6 years, is devoted to machine checkout and physics testing. The second phase lasts for 8 years and is devoted primarily to technology testing. This report describes the technology test program development for ITER, the ancillary equipment outside the torus necessary to support the test modules, the international collaboration aspects of conducting the test program on ITER, the requirements on the machine major parameters and the R and D program required to develop the test modules for testing in ITER. 15 refs, figs and tabs

  5. Pancreatic exocrine function testing

    International Nuclear Information System (INIS)

    Goff, J.S.

    1981-01-01

    It is important to understand which pancreatic function tests are available and how to interpret them when evaluating patients with malabsorption. Available direct tests are the secretin stimulation test, the Lundh test meal, and measurement of serum or fecal enzymes. Indirect tests assess pancreatic exocrine function by measuring the effect of pancreatic secretion on various nutrients. These include triglycerides labeled with carbon 14, cobalamin labeled with cobalt 57 and cobalt 58, and para-aminobenzoic acid bound to a dipeptide. Of all these tests the secretin stimulation test is the most accurate and reliable if done by experienced personnel. However, the indirect tests are simpler to do and appear to be comparable to the secretin test at detecting pancreatic exocrine insufficiency. These indirect tests are becoming clinically available and clinicians should familiarize themselves with the strengths and weaknesses of each

  6. Blanket testing in NET

    International Nuclear Information System (INIS)

    Chazalon, M.; Daenner, W.; Libin, B.

    1989-01-01

    The testing stages in NET for the performance assessment of the various breeding blanket concepts developed at the present time in Europe for DEMO (LiPb and ceramic blankets) and the requirements upon NET to perform these tests are reviewed. Typical locations available in NET for blanket testing are the central outboard segments and the horizontal ports of in-vessel sectors. These test positions will be connectable with external test loops. The number of test loops (helium, water, liquid metal) will be such that each major class of blankets can be tested in NET. The test positions, the boundary conditions and the external test loops are identified and the requirements for test blankets are summarized (author). 6

  7. Functional Testing Airborne Radars

    Science.gov (United States)

    1981-03-27

    recorded, and presented in accordance with this TOP? Yes No Comment : 2. Were the facilities, test equipment, instrumentation, and support accommo- dations...adequate to accomplish the test objectives? Yes No Comment : 3. Have all data collected been reviewed for correctness and completeness? Yes No ... Comment : 4. Were the test results compromised in any way due to insufficient test planning? Yes No . Comment : 5. Were the test results compromised in any

  8. Testing Aircraft Instruments.

    Science.gov (United States)

    1981-02-11

    1. Have test data been collected, recorded, and presented in accordance with this TOP? Yes No Comment : 2. Were the facilities, test equipment...instrumentation, and support accommodations adequate to accomplish the test objectives? Yes No Comment : 3. Have all data collected been reviewed for...correctness and completeness? Yes No Comment : 4. Were the test results compromised in any way due to insufficient test planning? Yes No Comment : 5. Were the

  9. Pancreatic Exocrine Function Testing

    OpenAIRE

    Berk, J. Edward

    1982-01-01

    It is important to understand which pancreatic function tests are available and how to interpret them when evaluating patients with malabsorption. Available direct tests are the secretin stimulation test, the Lundh test meal, and measurement of serum or fecal enzymes. Indirect tests assess pancreatic exocrine function by measuring the effect of pancreatic secretion on various nutrients. These include triglycerides labeled with carbon 14, cobalamin labeled with cobalt 57 and cobalt 58, and par...

  10. Testing experience with fast flux test facility

    International Nuclear Information System (INIS)

    Noordhoff, B.H.; McGough, C.B.; Nolan, J.E.

    1975-01-01

    Early FFTF project planning emphasized partial and full-scale testing of major reactor and plant prototype components under expected environmental conditions, excluding radiation fields. Confirmation of component performance during FFTF service was considered essential before actual FFTF startup, to provide increased assurance against FFTF startup delays or operational difficulties and downtime. Several new sodium facilities were constructed, and confirmation tests on the prototype components are now in progress. Test conditions and results to date are reported for the primary pump, intermediate heat exchanger, sodium-to-air dump heat exchanger, large and small sodium valves, purification cold trap, in-vessel handling machine, instrument tree, core restraint, control rod system, low-level flux monitor, closed loop ex-vessel machine, refueling equipment, and selected maintenance equipment. The significance and contribution of these tests to the FFTF and Liquid Metal Fast Breeder Reactor (LMFBR) program are summarized. (U.S.)

  11. Antimicrobials Products Tested or Pending Testing

    Science.gov (United States)

    The agency has completed testing of the majority of registered hospital disinfectants and tuberculocide products. The list of products can assist users in making informed choices regarding infection control in their facilities.

  12. The hardness test: a real mechanical test

    International Nuclear Information System (INIS)

    Rezakhanlou, R.

    1993-02-01

    During the service life, the mechanical properties of the PWR components change. It is necessary to determine precisely this evolution, but it is not always possible to draw a sample with the adequate size for the characterization. For this latter case we intend to calculate the stress-strain curve of a material from a hardness test results, because it is appropriate for testing on site and do not need any particular sample shape. This paper is the first bibliographical part of a larger study on the relation between the values measured during a hardness test (applied load, indentation diameter) and the mechanical properties of a solid obtained by a traction test. We have treated the problem within the general setting of two solids in contact. Thus, we expose general elastic, elasto-plastic and plastic models describing the indentation of a solid by a rigid indenter

  13. Test plan for core drilling ignitability testing

    International Nuclear Information System (INIS)

    Witwer, K.S.

    1996-01-01

    The objective of this testing is to determine if ignition occurs while core drilling in a flammable gas environment. Drilling parameters are chosen so as to provide bounding conditions for the core sampling environment. If ignition does not occur under the conditions set forth in this test, then a satisfactory level of confidence will be obtained which would allow field operations under the normal drilling conditions

  14. TESTING TESTS ON ACTIVE GALACTIC NUCLEI MICROVARIABILITY

    International Nuclear Information System (INIS)

    De Diego, Jose A.

    2010-01-01

    Literature on optical and infrared microvariability in active galactic nuclei (AGNs) reflects a diversity of statistical tests and strategies to detect tiny variations in the light curves of these sources. Comparison between the results obtained using different methodologies is difficult, and the pros and cons of each statistical method are often badly understood or even ignored. Even worse, improperly tested methodologies are becoming more and more common, and biased results may be misleading with regard to the origin of the AGN microvariability. This paper intends to point future research on AGN microvariability toward the use of powerful and well-tested statistical methodologies, providing a reference for choosing the best strategy to obtain unbiased results. Light curves monitoring has been simulated for quasars and for reference and comparison stars. Changes for the quasar light curves include both Gaussian fluctuations and linear variations. Simulated light curves have been analyzed using χ 2 tests, F tests for variances, one-way analyses of variance and C-statistics. Statistical Type I and Type II errors, which indicate the robustness and the power of the tests, have been obtained in each case. One-way analyses of variance and χ 2 prove to be powerful and robust estimators for microvariations, while the C-statistic is not a reliable methodology and its use should be avoided.

  15. Trends in software testing

    CERN Document Server

    Mohanty, J; Balakrishnan, Arunkumar

    2017-01-01

    This book is focused on the advancements in the field of software testing and the innovative practices that the industry is adopting. Considering the widely varied nature of software testing, the book addresses contemporary aspects that are important for both academia and industry. There are dedicated chapters on seamless high-efficiency frameworks, automation on regression testing, software by search, and system evolution management. There are a host of mathematical models that are promising for software quality improvement by model-based testing. There are three chapters addressing this concern. Students and researchers in particular will find these chapters useful for their mathematical strength and rigor. Other topics covered include uncertainty in testing, software security testing, testing as a service, test technical debt (or test debt), disruption caused by digital advancement (social media, cloud computing, mobile application and data analytics), and challenges and benefits of outsourcing. The book w...

  16. Pragmatics of Testing

    Directory of Open Access Journals (Sweden)

    İsmail Fırat ALTAY

    2007-10-01

    Full Text Available Teaching of a language is a very complicated issue and testing is anindispensable part of this matter. Thanks to testing teachers can assess efficiency ofteaching and learning atmosphere, and can get feedback about their learners. In order torealize this, a test should have some qualifications. One of these qualifications is aboutpragmatics. This paper aims at explaining what makes a test pragmatic and howpragmatic tests can be formed. So, examples of pragmatic tests of different types arepresented with explanations. Their pragmatic components and nature are focused on bygiving example test items on the problematic area of test questions prepared. Finally,the writer states his last words by making further comments and explanations onpragmatics of testing in the conclusion part.

  17. Relay test program

    International Nuclear Information System (INIS)

    Bandyopadhyay, K.K.; Kunkel, C.; Shteyngart, S.

    1994-02-01

    This report presents the results of a relay test program conducted by Brookhaven National Laboratory (BNL) under the sponsorship of the US Nuclear Regulatory Commission (NRC). The program is a continuation of an earlier test program the results of which were published in NUREG/CR-4867. The current program was carried out in two phases: electrical testing and vibration testing. The objective was primarily to focus on the electrical discontinuity or continuity of relays and circuit breaker tripping mechanisms subjected to electrical pulses and vibration loads. The electrical testing was conducted by KEMA-Powertest Company and the vibration testing was performed at Wyle Laboratories, Huntsville, Alabama. This report discusses the test procedures, presents the test data, includes an analysis of the data and provides recommendations regarding reliable relay testing

  18. Nondestructive testing of materials

    International Nuclear Information System (INIS)

    NUKEM has transferred know-how from reactor technology to materials testing. The high and to a large extent new quality standards in the nuclear industry necessitate reliable measuring and testing equipment of the highest precision. Many of the tasks presented to us could not be solved with the equipment available on the market, for which reason we have developed our own measuring, testing and control systems. We have therefore acquired considerable experience in dealing with specific measuring, testing and control tasks and can handle even out-of-the-way problems that are submitted to us from a wide variety of fields. Our mechanical systems for the checking of close-tolerance gaps, the automatic determination of pellet dimensions and the measurement of absolute lengths and absolute velocities are in use in many different industrial fields. We have succeeded in solving unusual testing and sorting problems with the aid of automated surface testing equipment working on optical principles. Our main activities in the field of non-destructive testing have been concentrated on ultrasonic and eddy current testing and, of late, acoustic emission analysis. NUKEM ultrasonic systems are notable for their high defect detection rate and testing accuracy, combined with high testing speed. The equipment we supply includes ultrasonic rotary systems for the production testing of quality tubes, ultrasonic immersion systems for the final testing of reactor cladding tubes, weld testing equipment, and test equipment for the bonds in multi-layer plates. (orig./RW) [de

  19. Gas Test Loop Booster Fuel Hydraulic Testing

    International Nuclear Information System (INIS)

    Gas Test Loop Hydraulic Testing Staff

    2006-01-01

    The Gas Test Loop (GTL) project is for the design of an adaptation to the Advanced Test Reactor (ATR) to create a fast-flux test space where fuels and materials for advanced reactor concepts can undergo irradiation testing. Incident to that design, it was found necessary to make use of special booster fuel to enhance the neutron flux in the reactor lobe in which the Gas Test Loop will be installed. Because the booster fuel is of a different composition and configuration from standard ATR fuel, it is necessary to qualify the booster fuel for use in the ATR. Part of that qualification is the determination that required thermal hydraulic criteria will be met under routine operation and under selected accident scenarios. The Hydraulic Testing task in the GTL project facilitates that determination by measuring flow coefficients (pressure drops) over various regions of the booster fuel over a range of primary coolant flow rates. A high-fidelity model of the NW lobe of the ATR with associated flow baffle, in-pile-tube, and below-core flow channels was designed, constructed and located in the Idaho State University Thermal Fluids Laboratory. A circulation loop was designed and constructed by the university to provide reactor-relevant water flow rates to the test system. Models of the four booster fuel elements required for GTL operation were fabricated from aluminum (no uranium or means of heating) and placed in the flow channel. One of these was instrumented with Pitot tubes to measure flow velocities in the channels between the three booster fuel plates and between the innermost and outermost plates and the side walls of the flow annulus. Flow coefficients in the range of 4 to 6.5 were determined from the measurements made for the upper and middle parts of the booster fuel elements. The flow coefficient for the lower end of the booster fuel and the sub-core flow channel was lower at 2.3

  20. Gas Test Loop Booster Fuel Hydraulic Testing

    Energy Technology Data Exchange (ETDEWEB)

    Gas Test Loop Hydraulic Testing Staff

    2006-09-01

    The Gas Test Loop (GTL) project is for the design of an adaptation to the Advanced Test Reactor (ATR) to create a fast-flux test space where fuels and materials for advanced reactor concepts can undergo irradiation testing. Incident to that design, it was found necessary to make use of special booster fuel to enhance the neutron flux in the reactor lobe in which the Gas Test Loop will be installed. Because the booster fuel is of a different composition and configuration from standard ATR fuel, it is necessary to qualify the booster fuel for use in the ATR. Part of that qualification is the determination that required thermal hydraulic criteria will be met under routine operation and under selected accident scenarios. The Hydraulic Testing task in the GTL project facilitates that determination by measuring flow coefficients (pressure drops) over various regions of the booster fuel over a range of primary coolant flow rates. A high-fidelity model of the NW lobe of the ATR with associated flow baffle, in-pile-tube, and below-core flow channels was designed, constructed and located in the Idaho State University Thermal Fluids Laboratory. A circulation loop was designed and constructed by the university to provide reactor-relevant water flow rates to the test system. Models of the four booster fuel elements required for GTL operation were fabricated from aluminum (no uranium or means of heating) and placed in the flow channel. One of these was instrumented with Pitot tubes to measure flow velocities in the channels between the three booster fuel plates and between the innermost and outermost plates and the side walls of the flow annulus. Flow coefficients in the range of 4 to 6.5 were determined from the measurements made for the upper and middle parts of the booster fuel elements. The flow coefficient for the lower end of the booster fuel and the sub-core flow channel was lower at 2.3.

  1. Metamorphic Testing for Cybersecurity.

    Science.gov (United States)

    Chen, Tsong Yueh; Kuo, Fei-Ching; Ma, Wenjuan; Susilo, Willy; Towey, Dave; Voas, Jeffrey; Zhou, Zhi Quan

    2016-06-01

    Testing is a major approach for the detection of software defects, including vulnerabilities in security features. This article introduces metamorphic testing (MT), a relatively new testing method, and discusses how the new perspective of MT can help to conduct negative testing as well as to alleviate the oracle problem in the testing of security-related functionality and behavior. As demonstrated by the effectiveness of MT in detecting previously unknown bugs in real-world critical applications such as compilers and code obfuscators, we conclude that software testing of security-related features should be conducted from diverse perspectives in order to achieve greater cybersecurity.

  2. Theory of nonparametric tests

    CERN Document Server

    Dickhaus, Thorsten

    2018-01-01

    This textbook provides a self-contained presentation of the main concepts and methods of nonparametric statistical testing, with a particular focus on the theoretical foundations of goodness-of-fit tests, rank tests, resampling tests, and projection tests. The substitution principle is employed as a unified approach to the nonparametric test problems discussed. In addition to mathematical theory, it also includes numerous examples and computer implementations. The book is intended for advanced undergraduate, graduate, and postdoc students as well as young researchers. Readers should be familiar with the basic concepts of mathematical statistics typically covered in introductory statistics courses.

  3. Metamorphic Testing for Cybersecurity

    Science.gov (United States)

    Chen, Tsong Yueh; Kuo, Fei-Ching; Ma, Wenjuan; Susilo, Willy; Towey, Dave; Voas, Jeffrey

    2016-01-01

    Testing is a major approach for the detection of software defects, including vulnerabilities in security features. This article introduces metamorphic testing (MT), a relatively new testing method, and discusses how the new perspective of MT can help to conduct negative testing as well as to alleviate the oracle problem in the testing of security-related functionality and behavior. As demonstrated by the effectiveness of MT in detecting previously unknown bugs in real-world critical applications such as compilers and code obfuscators, we conclude that software testing of security-related features should be conducted from diverse perspectives in order to achieve greater cybersecurity. PMID:27559196

  4. Comparative Test Case Specification

    DEFF Research Database (Denmark)

    Kalyanova, Olena; Heiselberg, Per

     This document includes a definition of the comparative test cases DSF200_3 and DSF200_4, which previously described in the comparative test case specification for the test cases DSF100_3 and DSF200_3 [Ref.1]....... This document includes a definition of the comparative test cases DSF200_3 and DSF200_4, which previously described in the comparative test case specification for the test cases DSF100_3 and DSF200_3 [Ref.1]....

  5. Proficiency Testing in Nondestructive Testing (NDT)

    International Nuclear Information System (INIS)

    Amry Amin Abbas; Suhairy Sani; Mohamad Pauzi Ismail; Abd Nassir Ibrahim

    2014-01-01

    Department of Standard Malaysia (DSM) launched myPTP programme on 31 December 2013 in accordance to ISO/IC 17043. The standard states the requirements for Proficiency Testing. The provider of these services is called Proficiency Testing Provider (PTP). The role of PTP is to compare the proficiency level between inspection bodies or laboratories. With the assistance of expert panel, the PTP will determine the assigned value as reference to be compared to the values obtained from the inspection bodies or laboratories. Quality wise, this services is important as participation will improve wuality of the inspection quality continuously and increase confidence level of client and improve safety level. Requirement of PT in NDT is mentioned in SC1.5- Specific Criteria for Accreditation of Mechanical Testing and Non-Destructive Testing (NDT) for MS ISO/IEC17025 and MTR2- MIBAS Technical Requirements for Accreditation of NDT. This paper explains and discusses the result of this proficiency test done on a number of NDT companies that participated. (author)

  6. Irradiation Effects Test Series: Test IE-2. Test results report

    International Nuclear Information System (INIS)

    Allison, C.M.; Croucher, D.W.; Ploger, S.A.; Mehner, A.S.

    1977-08-01

    The report describes the results of a test using four 0.97-m long PWR-type fuel rods with differences in diametral gap and cladding irradiation. The objective of this test was to provide information about the effects of these differences on fuel rod behavior during quasi-equilibrium and film boiling operation. The fuel rods were subjected to a series of preconditioning power cycles of less than 30 kW/m. Rod powers were then increased to 68 kW/m at a coolant mass flux of 4900 kg/s-m 2 . After one hour at 68 kW/m, a power-cooling-mismatch sequence was initiated by a flow reduction at constant power. At a flow of 2550 kg/s-m 2 , the onset of film boiling occurred on one rod, Rod IE-011. An additional flow reduction to 2245 kg/s-m 2 caused the onset of film boiling on the remaining three rods. Data are presented on the behavior of fuel rods during quasiequilibrium and during film boiling operation. The effects of initial gap size, cladding irradiation, rod power cycling, a rapid power increase, and sustained film boiling are discussed. These discussions are based on measured test data, preliminary postirradiation examination results, and comparisons of results with FRAP-T3 computer model calculations

  7. Visual acuity test

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003396.htm Visual acuity test To use the sharing features on this page, please enable JavaScript. The visual acuity test is used to determine the smallest ...

  8. Learning Python testing

    CERN Document Server

    Arbuckle, Daniel

    2014-01-01

    This book is ideal if you want to learn about the testing disciplines and automated testing tools from a hands-on, conversational guide. You should already know Python and be comfortable with Python 3.

  9. EMI Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Supports electromagnetic interference/radio frequency interference (EMI/RFI) testing of flight hardware. It is also used to support custom RF testing up to...

  10. Urine specific gravity test

    Science.gov (United States)

    ... medlineplus.gov/ency/article/003587.htm Urine specific gravity test To use the sharing features on this page, please enable JavaScript. Urine specific gravity is a laboratory test that shows the concentration ...

  11. Ballistic Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Ballistic Test Facility is comprised of two outdoor and one indoor test ranges, which are all instrumented for data acquisition and analysis. Full-size aircraft...

  12. Ultrasonic testing X gammagraphy

    International Nuclear Information System (INIS)

    Mello Campos, A.M. de

    1989-01-01

    The experience of 10 years for substituting gammagraphy tests by ultrasonic tests is related. A comparative evaluation of data obtained from both techniques applied to welded butt joints is presented. (author)

  13. Extraocular muscle function testing

    Science.gov (United States)

    ... medlineplus.gov/ency/article/003397.htm Extraocular muscle function testing To use the sharing features on this page, please enable JavaScript. Extraocular muscle function testing examines the function of the eye muscles. ...

  14. Platelet Function Tests

    Science.gov (United States)

    ... Patient Resources For Health Professionals Subscribe Search Platelet Function Tests Send Us Your Feedback Choose Topic At ... Also Known As Platelet Aggregation Studies PFT Platelet Function Assay PFA Formal Name Platelet Function Tests This ...

  15. Variable Attitude Test Stand

    Data.gov (United States)

    Federal Laboratory Consortium — The Variable Attitude Test Stand designed and built for testing of the V-22 tilt rotor aircraft propulsion system, is used to evaluate the effect of aircraft flight...

  16. Insensitive Munitions Testing

    Data.gov (United States)

    Federal Laboratory Consortium — Insensitive Munitions Testing at RTC is conducted (IAW MILSTD-2105) at Test Area 4. Our engineers and technicians obtain data for hazards classification and safety...

  17. Lab and Imaging Tests

    Science.gov (United States)

    ... tests to help detect (diagnose) a blood cancer (leukemia, lymphoma, myeloma, myelodysplastic syndromes or myeloproliferative disease). You may need to undergo additional tests to confirm your diagnosis. Once your diagnosis is confirmed, your doctor may ...

  18. Learning Android application testing

    CERN Document Server

    Blundell, Paul

    2015-01-01

    If you are an Android developer looking to test your applications or optimize your application development process, then this book is for you. No previous experience in application testing is required.

  19. Genetic Testing for ALS

    Science.gov (United States)

    ... genetic counselor can help you work through the pros and cons of genetic testing based on your ... showing symptoms or what their progression will be. Technology is changing rapidly and costs of testing are ...

  20. Atlantic Test Range (ATR)

    Data.gov (United States)

    Federal Laboratory Consortium — ATR controls fully-instrumented and integrated test ranges that provide full-service support for cradle-to-grave testing. Airspace and surface target areas are used...

  1. The Danish National Tests

    DEFF Research Database (Denmark)

    Beuchert, Louise Voldby; Nandrup, Anne Brink

    In 2010, the Danish National Tests were implemented in the public compulsory schools as a mean of evaluating the performance of the public school system. The extensive test program consists of ten mandatory tests in six subjects in grades 2 through 8. In this paper, we share our insights from wor...... characteristics as well as pupils' 9th grade examination marks. We document a stable test score gap across grade levels and socio economic background and discuss the prospects of the national test data for future research....... within each test and argue that this is often a more feasible measure for data analyses compared to the transformed test score presented to pupils and teachers. We provide the reader with preliminary analyses of the relation between pupils' national test results and a wide range of pupil background...

  2. Uric acid test (image)

    Science.gov (United States)

    Uric acid urine test is performed to check for the amount of uric acid in urine. Urine is collected over a 24 ... for testing. The most common reason for measuring uric acid levels is in the diagnosis or treatment of ...

  3. Ethylene glycol blood test

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003564.htm Ethylene glycol blood test To use the sharing features ... enable JavaScript. This test measures the level of ethylene glycol in the blood. Ethylene glycol is a ...

  4. hs-CRP Test

    Science.gov (United States)

    ... the sample? No test preparation is needed; however, fasting for 9-12 hours before the blood sample ... such as colon cancer , complications of diabetes , and obesity. I have had cholesterol tests but never an ...

  5. Understanding Laboratory Tests

    Science.gov (United States)

    ... and Drug Administration (FDA) regulates the development and marketing of all laboratory tests that use test kits ... Cancer.gov en español Multimedia Publications Site Map Digital Standards for NCI Websites POLICIES Accessibility Comment Policy ...

  6. Corrosion Testing Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Corrosion Testing Facility is part of the Army Corrosion Office (ACO). It is a fully functional atmospheric exposure site, called the Corrosion Instrumented Test...

  7. Rocketball Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — This test facility offers the capability to emulate and measure guided missile radar cross-section without requiring flight tests of tactical missiles. This facility...

  8. PT and INR Test

    Science.gov (United States)

    ... Plasma Free Metanephrines Platelet Count Platelet Function Tests Pleural Fluid Analysis PML-RARA Porphyrin Tests Potassium Prealbumin ... and vitamin K (either in a multivitamin or liquid nutrition supplement) may decrease PT. Certain foods, such ...

  9. Helicobacter pylori Test

    Science.gov (United States)

    ... Plasma Free Metanephrines Platelet Count Platelet Function Tests Pleural Fluid Analysis PML-RARA Porphyrin Tests Potassium Prealbumin ... collected and then the person is given a liquid to drink. Another breath sample is collected at ...

  10. Static Loads Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Provides the capability to perform large-scale structural loads testing on spacecraft and other structures. Results from these tests can be used to verify...

  11. Antidiuretic hormone blood test

    Science.gov (United States)

    ... medlineplus.gov/ency/article/003702.htm Antidiuretic hormone blood test To use the sharing features on this page, please enable JavaScript. Antidiuretic blood test measures the level of antidiuretic hormone (ADH) in ...

  12. Gastrin blood test

    Science.gov (United States)

    Peptic ulcer - gastrin blood test ... A blood sample is needed . ... in the stomach, gastrin is released into the blood. As the acid ... provider may order this test if you have signs or symptoms of a ...

  13. HCG blood test - qualitative

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003509.htm HCG blood test - qualitative To use the sharing features on this page, please enable JavaScript. A qualitative HCG blood test checks if there is a hormone called human ...

  14. ACE blood test

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003567.htm ACE blood test To use the sharing features on this page, ... Alternative Names Serum angiotensin-converting enzyme; SACE Images Blood test References Carty RP, Pincus MR, Sarafraz-Yazdi E. ...

  15. LDH isoenzyme blood test

    Science.gov (United States)

    ... medlineplus.gov/ency/article/003499.htm LDH isoenzyme blood test To use the sharing features on this page, ... Names LD; LDH; Lactic (lactate) dehydrogenase isoenzymes Images Blood test References Carty RP, Pincus MR, Sarafraz-Yazdi E. ...

  16. Phosphorus blood test

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003478.htm Phosphorus blood test To use the sharing features on this page, please enable JavaScript. The phosphorus blood test measures the amount of phosphate in the blood. ...

  17. CEA blood test

    Science.gov (United States)

    Carcinoembryonic antigen blood test ... doing so for a short time before the test. ... When the needle is inserted to draw blood, some people feel ... may be some throbbing or a slight bruise. This soon goes away.

  18. Methylmalonic acid blood test

    Science.gov (United States)

    ... medlineplus.gov/ency/article/003565.htm Methylmalonic acid blood test To use the sharing features on this page, please enable JavaScript. The methylmalonic acid blood test measures the amount of methylmalonic acid in the ...

  19. TBG - blood test

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003374.htm TBG - blood test To use the sharing features on this page, please enable JavaScript. The TBG blood test measures the level of a protein that moves ...

  20. Calcitonin blood test

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003699.htm Calcitonin blood test To use the sharing features on this page, please enable JavaScript. The calcitonin blood test measures the level of the hormone calcitonin in ...

  1. Calcium blood test

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003477.htm Calcium blood test To use the sharing features on this page, please enable JavaScript. The calcium blood test measures the level of calcium in the blood. ...

  2. Aldolase blood test

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003566.htm Aldolase blood test To use the sharing features on this page, ... risk any time the skin is broken) Images Blood test References Berridge BR, Van Vleet JF, Herman E. ...

  3. Glucagon blood test

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003716.htm Glucagon blood test To use the sharing features on this page, please enable JavaScript. A glucagon blood test measures the amount of a hormone called glucagon ...

  4. Leucine aminopeptidase blood test

    Science.gov (United States)

    ... medlineplus.gov/ency/article/003559.htm Leucine aminopeptidase blood test To use the sharing features on this page, ... Alternative Names Serum leucine aminopeptidase; LAP - serum Images Blood test References Chernecky CC, Berger BJ. Leucine aminopeptidase (LAP) - ...

  5. Pyruvate kinase blood test

    Science.gov (United States)

    ... medlineplus.gov/ency/article/003357.htm Pyruvate kinase blood test To use the sharing features on this page, ... energy when oxygen levels are low. How the Test is Performed A blood sample is needed. In the laboratory, white blood ...

  6. Ammonia blood test

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003506.htm Ammonia blood test To use the sharing features on this page, ... Encephalopathy - ammonia; Cirrhosis - ammonia; Liver failure - ammonia Images Blood test References Chernecky CC, Berger BJ. Ammonia (NH3) - blood ...

  7. Antithrombin III blood test

    Science.gov (United States)

    ... medlineplus.gov/ency/article/003661.htm Antithrombin III blood test To use the sharing features on this page, ... a protein that helps control blood clotting. A blood test can determine the amount of AT III present ...

  8. Fibrinopeptide A blood test

    Science.gov (United States)

    ... medlineplus.gov/ency/article/003373.htm Fibrinopeptide A blood test To use the sharing features on this page, ... measure the level of this substance in your blood. How the Test is Performed A blood sample is needed. How ...

  9. Tularemia blood test

    Science.gov (United States)

    Tularemia test; Serology for Francisella tularensis ... This blood test is done when tularemia is suspected. ... Elsevier; 2017:chap 44. Chernecky CC, Berger BJ. Tularemia agglutinins - serum. In: Chernecky CC, Berger BJ, eds. ...

  10. RBC urine test

    Science.gov (United States)

    ... measurement for a result of this test. Normal value ranges may vary slightly among different laboratories. Some labs use different measurements or test different samples. Talk to your provider ...

  11. Mantoux Tuberculin Skin Test

    Centers for Disease Control (CDC) Podcasts

    Learn how to evaluate people for latent TB infection with the Mantoux tuberculin skin test. This podcast includes sections on administering and reading the Mantoux tuberculin skin test, the standard method for detecting latent TB infection since the 1930s.

  12. Large scale reflood test

    International Nuclear Information System (INIS)

    Hirano, Kemmei; Murao, Yoshio

    1980-01-01

    The large-scale reflood test with a view to ensuring the safety of light water reactors was started in fiscal 1976 based on the special account act for power source development promotion measures by the entrustment from the Science and Technology Agency. Thereafter, to establish the safety of PWRs in loss-of-coolant accidents by joint international efforts, the Japan-West Germany-U.S. research cooperation program was started in April, 1980. Thereupon, the large-scale reflood test is now included in this program. It consists of two tests using a cylindrical core testing apparatus for examining the overall system effect and a plate core testing apparatus for testing individual effects. Each apparatus is composed of the mock-ups of pressure vessel, primary loop, containment vessel and ECCS. The testing method, the test results and the research cooperation program are described. (J.P.N.)

  13. Test Preparation: Your Role

    Science.gov (United States)

    ... eating cooked meat may be required since some studies have shown that eating cooked meat prior to testing can temporarily increase the level of creatinine. Fecal occult blood test : certain food and/or medication restrictions may be required. Urine ...

  14. Testing for HIV

    Science.gov (United States)

    ... Medical Devices Radiation-Emitting Products Vaccines, Blood & Biologics Animal & Veterinary Cosmetics Tobacco Products Vaccines, Blood & Biologics Home Vaccines, Blood & Biologics Safety & Availability (Biologics) HIV Home Test Kits Testing for HIV Share Tweet Linkedin Pin it More ...

  15. Radiated Emissions Test Approach

    Science.gov (United States)

    2015-10-02

    1. Draft Department of Transportation (DOT) Test Plan to Develop : Interference Tolerance Masks for GNSS Receivers in the L1 : Radiofrequency Band (1559 1610 MHz) provides high level : overview of radiated emissions test setup : 2. Presenta...

  16. HPV DNA test

    Science.gov (United States)

    ... test; Cancer of cervix - HPV DNA test References Hacker NF. Cervical dysplasia and cancer. In: Hacker NF, Gambone JC, Hobel CJ, eds. Hacker and Moore's Essentials of Obstetrics and Gynecology . 6th ...

  17. Cross cultural usability testing

    DEFF Research Database (Denmark)

    Clemmensen, Torkil; Goyal, Shivam

    2005-01-01

    In this paper, we present the results of a pilot study in Denmark of cross cultural effects on Think Aloud usability testing. We provide an overview of previous research on cross cultural usability evaluation with a special focus on the relationship between the evaluator and the test user....... This relation was studied in an experiment with usability testing of a localized clipart application in which eight participants from Denmark and India formed pairs of evaluator-test user. The test users were asked to think aloud and the evaluators' role were to facilitate the test users thinking aloud...... and hereby identify usability problems with the clipart application. Data on the evaluators' and test users' behaviour were recorded and analyzed by coding and summarizing statistics on these behavioural events. The results show that Think Aloud Usability Test of a localized application is most effectively...

  18. Environmental Test Facility (ETF)

    Data.gov (United States)

    Federal Laboratory Consortium — The Environmental Test Facility (ETF) provides non-isolated shock testing for stand-alone equipment and full size cabinets under MIL-S-901D specifications. The ETF...

  19. The first PANDA tests

    International Nuclear Information System (INIS)

    Dreier, J.; Huggenberger, M.; Aubert, C.

    1996-01-01

    The PANDA test facility at PSI in Switzerland is used to study the long-term Simplified Boiling Water Reactor (SBWR) Passive Containment Cooling System (PCCS) performance. The PANDA tests demonstrate performance on a larger scale than previous tests and examine the effects of any non-uniform spatial distributions of steam and non-condensables in the system. The PANDA facility has a 1:1 vertical scale, and 1:25 ''system'' scale (volume, power, etc.). Steady-state PCCS condenser performance tests and extensive facility characterization tests have been completed. Transient system behavior tests were conducted late in 1995; results from the first three transient tests (M3 series) are reviewed. The first PANDA tests showed that the overall global behavior of the SBWR containment was globally repeatable and very favorable; the system exhibited great ''robustness.''

  20. Growth hormone stimulation test

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003377.htm Growth hormone stimulation test To use the sharing features on this page, please enable JavaScript. The growth hormone (GH) stimulation test measures the ability of ...

  1. USA Hire Testing Platform

    Data.gov (United States)

    Office of Personnel Management — The USA Hire Testing Platform delivers tests used in hiring for positions in the Federal Government. To safeguard the integrity of the hiring processes and ensure...

  2. Shock resistance testing

    International Nuclear Information System (INIS)

    Pouard, M.

    1984-03-01

    In the framework of mechanical tests and to answer the different requests for tests, the T.C.R (Transport Conditionnement et Retraitement) laboratory got test facilities. These installations allow to carry out tests of resistance to shocks, mainly at the safety level of components of nuclear power plants, mockups of transport casks for fuel elements and transport containers for radioactive materials. They include a tower and a catapult. This paper give a decription of the facilities and explain their operation way [fr

  3. Tests in Print II: An Index to Tests, Test Reviews, and the Literature on Specific Tests.

    Science.gov (United States)

    Buros, Oscar K., Ed.

    Tests in Print II is a comprehensive, annotated bibliography of all in-print tests published as separates for use with English-speaking subjects. The 1,155 two-column pages list 2,467 tests in print as of early 1974; 16,574 references through 1971 on specific tests; a reprinting of the 1974 APA-AERA-NCME Standards for Educational andPsychological…

  4. Liquid Rocket Engine Testing

    Science.gov (United States)

    2016-10-21

    Briefing Charts 3. DATES COVERED (From - To) 17 October 2016 – 26 October 2016 4. TITLE AND SUBTITLE Liquid Rocket Engine Testing 5a. CONTRACT NUMBER...298 (Rev. 8-98) Prescribed by ANSI Std. 239.18 Liquid Rocket Engine Testing SFTE Symposium 21 October 2016 Jake Robertson, Capt USAF AFRL...Distribution Unlimited. PA Clearance 16493 Liquid Rocket Engine Testing • Engines and their components are extensively static-tested in development • This

  5. Probe tests microweld strength

    Science.gov (United States)

    1965-01-01

    Probe is developed to test strength of soldered, brazed or microwelded joints. It consists of a spring which may be adjusted to the desired test pressure by means of a threaded probe head, and an indicator lamp. Device may be used for electronic equipment testing.

  6. Language Testing in Japan.

    Science.gov (United States)

    Brown, James Dean, Ed.; Yamashita, Sayoko Okada, Ed.

    Papers on second language testing in Japan include: "Differences Between Norm-Referenced and Criterion-Referenced Tests" (James Dean Brown); "Criterion-Referenced Test Construction and Evaluation" (Dale T. Griffe); "Behavioral Learning Objectives as an Evaluation Tool" (Judith A. Johnson); "Developing Norm-…

  7. [Memory Checking Tests].

    Science.gov (United States)

    Hart, Joseph T.

    Two basic tests for checking memory skills are included in these appendices. The first, the General Information Test, uses the same 150 items for each of its two versions. One version is a completion-type test which measures recall by requiring the examinee to supply a specific response. The other version supplements each of the 150 items with…

  8. Get Tested for HIV

    Science.gov (United States)

    ... AIDS: What is HIV/AIDS? Women and HIV/AIDS Next section ... Tested? Why do I need to get tested for HIV? The only way to know if you have HIV is to get tested. Many people with HIV don’t have any symptoms. In the United States, about 1 in 7 ...

  9. Testing Backbone.js

    CERN Document Server

    Roemer, Ryan

    2013-01-01

    This book is packed with the step by step tutorial and instructions in recipe format helping you setup test infrastructure and gradually advance your skills to plan, develop, and test your backbone applications.If you are a JavaScript developer looking for recipes to create and implement test support for your backbone application, then this book is ideal for you.

  10. Automation of radiometric testing

    International Nuclear Information System (INIS)

    Chekalin, A.S.; Temnik, A.K.; Butakova, G.E.; Goncharov, V.I.

    1983-01-01

    The main prerequisites for creation of automatic systems of radiometric testing as the means to increase the testing objectivity and quality have been considered, principles of their design being developed. The operating system is described for testing complex configuration products using RD-10R gamma flow detector as a sensor of initial information

  11. Estradiol blood test

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003711.htm Estradiol blood test To use the sharing features on this page, ... of estrogens. How the Test is Performed A blood sample is needed . How to Prepare for the Test Your health care provider may tell you to ...

  12. Nuclear Test Personnel Review

    Science.gov (United States)

    FOIA Electronic Reading Room Privacy Impact Assessment DTRA No Fear Act Reporting Nuclear Test Personnel Review NTPR Fact Sheets NTPR Radiation Dose Assessment Documents US Atmospheric Nuclear Test History Documents US Underground Nuclear Test History Reports NTPR Radiation Exposure Reports Enewetak

  13. 2017 Census Test

    Science.gov (United States)

    /Programs Latest Information Are you in a Survey? 2020 Census 2018 Census Test 2010 Census American Information Surveys/Programs Main Are you in a Survey? 2020 Census 2018 Census Test If you have received a Census. Latest Information The 2018 Census Test will take place in Pierce County, Wash.; Providence

  14. Usability testing for dummies

    CERN Multimedia

    CERN. Geneva

    2017-01-01

    Usability testing seems complicated and time-consuming. Is it though? In fact, it is the best way to understand how real users experience your product. In this interactive session, we will do a live usability test and you will get advice on how to conduct your own usability tests.

  15. Barron's SAT subject test

    CERN Document Server

    Jansen, MA, Robert

    2016-01-01

    Includes one diagnostic test and three complete tests, all questions answered and explained, self-assessment guides, and subject reviews. Also features test strategies, QR codes to short instructional videos, and a detailed appendix with equations, physical constants, and a basic math review.

  16. Toroid magnet test facility

    CERN Multimedia

    2002-01-01

    Because of its exceptional size, it was not feasible to assemble and test the Barrel Toroid - made of eight coils - as an integrated toroid on the surface, prior to its final installation underground in LHC interaction point 1. It was therefore decided to test these eight coils individually in a dedicated test facility.

  17. Dismantling the Mantel tests

    DEFF Research Database (Denmark)

    Guillot, Gilles

    The simple and partial Mantel tests are routinely used in many areas of evolutionary biology to assess the significance of the association between two or more matrices of distances relative to the same pairs of individuals or demes. Partial Mantel tests rather than simple Mantel tests are widely...

  18. Dismantling the Mantel tests

    DEFF Research Database (Denmark)

    Guillot, Gilles; Rousset, François

    2012-01-01

    1. The simple and partialMantel tests are routinely used in many areas of evolutionary biology to assess the significance of the association between two ormorematrices of distances relative to the same pairs of individuals or demes. Partial Mantel tests rather than simple Mantel tests are widely...

  19. A test management approach for structured testing

    NARCIS (Netherlands)

    Veenendaal, van E.P.W.M.; Pol, M.; Veenendaal, van E.P.W.M.; McMullan, J.

    1997-01-01

    Despite encouraging results with various quality improvement approaches, the IT industry is still far from achieving zero defect software. Testing will remain an important activity within software development and maintenance, often taking more than 30 - 40% of the total budget. Both the increasing

  20. Grimsel Test Site: heat test, final report

    International Nuclear Information System (INIS)

    Schneefuss, J.; Glaess, F.; Gommlich, G.; Schmidt, M.

    1989-05-01

    The Swiss concept for the storage of radioactive waste consists in placing it in compact, dense rock formations. An experiment 'Heat Test' carried out by the 'Gesellschaft fuer Strahlen- und Umweltforschung' in Nagra's Grimsel rock laboratory simulated the heat production of stored radioactive waste. The aim was to evaluate processes for the demonstration of the suitability of a final repository for heat-producing radioactive waste in cristalline rock, to investigate the thermic, mechanic and hydraulic reactions to an artificial heat source, and to develop corresponding calculating models. The duration of the tests was about 3 years. In this report the measured thermic, mechanic and hydraulic reactions are documented and discussed in detail. A simple, rotation symmetrical FEM-model was used for the preparatory and experiment-accompanying modelling of the thermomechanical conditions in the heat test. The test showed that suitable measuring methods for the surveillance of the geomechanics of a final repository are available and that the reactions of the crystalline host rock to the heat source remain locally limited and can be modelled with relatively small effort. 29 refs., 33 figs., 10 tabs

  1. Toroidal simulation magnet tests

    International Nuclear Information System (INIS)

    Walstrom, P.L.; Domm, T.C.

    1975-01-01

    A number of different schemes for testing superconducting coils in a simulated tokamak environment are analyzed for their merits relative to a set of test criteria. Two of the concepts are examined in more detail: the so-called cluster test scheme, which employs two large background field coils, one on either side of the test coil, and the compact torus, a low-aspect ratio toroidal array of a small number of coils in which all of the coils are essentially test coils. Simulation of the pulsed fields of the tokamak is discussed briefly

  2. 100 statistical tests

    CERN Document Server

    Kanji, Gopal K

    2006-01-01

    This expanded and updated Third Edition of Gopal K. Kanji's best-selling resource on statistical tests covers all the most commonly used tests with information on how to calculate and interpret results with simple datasets. Each entry begins with a short summary statement about the test's purpose, and contains details of the test objective, the limitations (or assumptions) involved, a brief outline of the method, a worked example, and the numerical calculation. 100 Statistical Tests, Third Edition is the one indispensable guide for users of statistical materials and consumers of statistical information at all levels and across all disciplines.

  3. Testing of abrasion materials

    International Nuclear Information System (INIS)

    Hummert, G.

    1983-01-01

    A method of abrasion testing according to ASTM C 704-76 a is presented for steel fibre concrete mortar, fusion-cast basalt and a surface coating material and results of practical interest are mentioned. Due to the high technical demands on these materials and their specific fields of application, the very first test already supplied interesting findings. From the user's point of view, the method is an interesting alternative to the common test methods, e.g. according to DIN 52 108 (wheel test according to Boehme). In English-speaking countries, testing according to ASTM is often mandatory in the refractory industry in order to assure constant quality of refractory materials after setting. The method is characterized by good comparability and high accuracy of measurement. Only the test piece is exchanged while the test conditions remain constant, so that accurate information on the material studied is obtained. (orig.) [de

  4. Earthquake likelihood model testing

    Science.gov (United States)

    Schorlemmer, D.; Gerstenberger, M.C.; Wiemer, S.; Jackson, D.D.; Rhoades, D.A.

    2007-01-01

    INTRODUCTIONThe Regional Earthquake Likelihood Models (RELM) project aims to produce and evaluate alternate models of earthquake potential (probability per unit volume, magnitude, and time) for California. Based on differing assumptions, these models are produced to test the validity of their assumptions and to explore which models should be incorporated in seismic hazard and risk evaluation. Tests based on physical and geological criteria are useful but we focus on statistical methods using future earthquake catalog data only. We envision two evaluations: a test of consistency with observed data and a comparison of all pairs of models for relative consistency. Both tests are based on the likelihood method, and both are fully prospective (i.e., the models are not adjusted to fit the test data). To be tested, each model must assign a probability to any possible event within a specified region of space, time, and magnitude. For our tests the models must use a common format: earthquake rates in specified “bins” with location, magnitude, time, and focal mechanism limits.Seismology cannot yet deterministically predict individual earthquakes; however, it should seek the best possible models for forecasting earthquake occurrence. This paper describes the statistical rules of an experiment to examine and test earthquake forecasts. The primary purposes of the tests described below are to evaluate physical models for earthquakes, assure that source models used in seismic hazard and risk studies are consistent with earthquake data, and provide quantitative measures by which models can be assigned weights in a consensus model or be judged as suitable for particular regions.In this paper we develop a statistical method for testing earthquake likelihood models. A companion paper (Schorlemmer and Gerstenberger 2007, this issue) discusses the actual implementation of these tests in the framework of the RELM initiative.Statistical testing of hypotheses is a common task and a

  5. Teacher Test Accountability.

    Directory of Open Access Journals (Sweden)

    Larry H. Ludlow

    2001-02-01

    Full Text Available Given the high stakes of teacher testing, there is no doubt that every teacher test should meet the industry guidelines set forth in the Standards for Educational and Psychological Testing. Unfortunately, however, there is no public or private business or governmental agency that serves to certify or in any other formal way declare that any teacher test does, in fact, meet the psychometric recommendations stipulated in the Standards. Consequently, there are no legislated penalties for faulty products (tests nor are there opportunities for test takers simply to raise questions about a test and to have their questions taken seriously by an impartial panel. The purpose of this article is to highlight some of the psychometric results reported by National Evaluation Systems (NES in their 1999 Massachusetts Educator Certification Test (MECT Technical Report, and more specifically, to identify those technical characteristics of the MECT that are inconsistent with the Standards. A second purpose of this article is to call for the establishment of a standing test auditing organization with investigation and sanctioning power. The significance of the present analysis is twofold: a psychometric results for the MECT are similar in nature to psychometric results presented as evidence of test development flaws in an Alabama class-action lawsuit dealing with teacher certification (an NES-designed testing system; and b there was no impartial enforcement agency to whom complaints about the Alabama tests could be brought, other than the court, nor is there any such agency to whom complaints about the Massachusetts tests can be brought. I begin by reviewing NES's role in Allen v. Alabama State Board of Education, 81-697-N. Next I explain the purpose and interpretation of standard item analysis procedures and statistics. Finally, I present results taken directly from the 1999 MECT Technical Report and compare them to procedures, results, and consequences of

  6. Fracture evaluation tests

    International Nuclear Information System (INIS)

    Robinson, G.C.

    1991-01-01

    In this report period, efforts have concentrated on defining the requirements for shallow-flaw beam testing. Analyses have been made to envelope the significant parameters for both deep- and shallow-flaw beams for three-point loading; that is, load to initiation of a frangible flaw, load to plastic collapse, LLD, and CMOD. An assessment was made of facilities capable of performing the tests identified by the parametric analyses discussed above. Two testing machines were identified for performing the scoped test series, the first a 550-kip Instron machine assigned to the Pressure Vessel Technology Section located in Building 9204-1 at the Y-12 Plant and the second a 220-kip MTS machine assigned to a mechanical testing group located at the K-25 Site. An existing bend test fixture previously used in the HSST clad plate test series is being modified for use in testing beams under other sponsorship but will be available for shared usage with the HSST shallow-flaw beam testing activities. To prevent the shared usage from having an adverse impact on the logistics of the HSST Program, the decision was made to procure a bend test fixture tailored specifically to serve the shallow flaw beam test series. A specification was prepared and procurement initiated. A survey is in progress for determining sources and costs of displacement-measuring instrumentation from both foreign and domestic sources. It appears that existing direct current displacement transducers available to the HSST Program may be adequate for the LLD measurements. These devices will be employed in the shakedown tests that are planned. A safety and environmental survey assessment for the beam testing conforming to the revised DOE rules has been prepared and approved

  7. Test Results for CSTR Test 4

    International Nuclear Information System (INIS)

    Lee, D.D.

    2001-01-01

    One of the 3 technologies currently being developed for the Savannah River Salt Waste Processing Program is the Small-Tank Tetraphenylborate Process (STTP). This process uses sodium tetraphenylborate to precipitate and remove radioactive Cs from the waste and monosodium titanate to sorb and remove radioactive Sr and actinides. ORNL is demonstrating this process at the 1:4000 scale using a 20-liter continuous-flow stirred tank reactor (CSTR) system. The primary goal of Test 4 was to verify that the STTP process could achieve and maintain the necessary Cs decontamination while TPB was actively decomposing. Even with TPB being decomposed by the off-normal conditions of this test, the decontaimination factor for 137 Cs obtained for the filtrate from the Slurry Concentrating Tank ranged from 47,000 to 646,000, exceeding the WAC standard

  8. Hot ductility testing and weld simulation tests

    International Nuclear Information System (INIS)

    Weber, G.; Schick, M.

    1999-01-01

    The objective of the project was to enhance the insight into the causes of intergranular cracks detected in austenitic circumferential welds at BWR pipes. The susceptibility of a variety of austenitic pipe materials to hot cracking during welding and in-service intergranular crack corrosion was examined. The assumption was cracking in the root area of the HAZ of a multiple-layer weld. Hot-ductility tests and weld simulation tests specifically designed for the project were performed with the austenitic LWR pipe materials 1.4553 (X6 CrNiNb 18 10 S), 1.4550 (X10 CrNiNb 18 9), 1.4533 (X6 CrNiTi 18 9, two weld pools), and a non-stabilized TP 304 (X5 CrNi 18 10). (orig./CB) [de

  9. Standard Test Method for Sandwich Corrosion Test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method defines the procedure for evaluating the corrosivity of aircraft maintenance chemicals, when present between faying surfaces (sandwich) of aluminum alloys commonly used for aircraft structures. This test method is intended to be used in the qualification and approval of compounds employed in aircraft maintenance operations. 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information. 1.3 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements appear in Section 9.

  10. Testing of the structural evaluation test unit

    International Nuclear Information System (INIS)

    Ammerman, D.J.; Bobbe, J.G.

    1995-01-01

    In the evaluation of the safety of radioactive material transportation it is important to consider the response of Type B packages to environments more severe than that prescribed by the hypothetical accident sequence in Title 10 Part 71 of the Code of Federal Regulations (NRC 1995). The impact event in this sequence is a 9-meter drop onto an essentially unyielding target, resulting in an impact velocity of 13.4 m/s. The behavior of 9 packages when subjected to impacts more severe than this is not well known. It is the purpose of this program to evaluate the structural response of a test package to these environments. Several types of structural response are considered. Of primary importance is the behavior of the package containment boundary, including the bolted closure and 0-rings. Other areas of concern are loss of shielding capability due to lead slump and the deceleration loading of package contents, that may cause damage to them. This type of information is essential for conducting accurate risk assessments on the transportation of radioactive materials. Currently very conservative estimates of the loss of package protection are used in these assessments. This paper will summarize the results of a regulatory impact test and three extra-regulatory impact tests on a sample package

  11. Test, dannelse og faglighed

    DEFF Research Database (Denmark)

    Schou, Lotte Rahbek

    2013-01-01

    Erfaringer fra blandt andet USA viser, at indførelse af obligatoriske nationale test får stor betydning for, hvilke former for faglighed der bliver dominerende i skolens undervisning. Hensigten har været at styrke de former for viden, som faktisk kan testes – ikke på bekostning af andre vidensfor...... vidensformer og indsigter - men simpelthen for blot at blive bedre til de dele af fagligheden, som kan testes. Forskning peger dog på, at obligatoriske test ikke blot styrker dele af fagligheden, men snarere bliver fuldstændig determinerende for hele fagligheden.......Erfaringer fra blandt andet USA viser, at indførelse af obligatoriske nationale test får stor betydning for, hvilke former for faglighed der bliver dominerende i skolens undervisning. Hensigten har været at styrke de former for viden, som faktisk kan testes – ikke på bekostning af andre...

  12. Pilocarpine iontophoresis test

    DEFF Research Database (Denmark)

    Hjortskov, N; Jepsen, Leif; Nielsen, B

    1995-01-01

    The pilocarpine iontophoresis test (P-test) is used as a predictor of the capacity to produce sweat. Therefore, we studied the reproducibility of this test in 12 normal subjects on 10 consecutive days. Furthermore, we determined whether the P-test reflects whole-body and regional sweat secretion...... during exercise in the heat. Finally, we determined whether the P-test stimulates the eccrine sweat glands to maximal sweat secretion. Six growth hormone-deficient (GHD) patients who are known to have decreased sweating, and 11 healthy control subjects were studied. To induce maximal sweat secretion......, the patients exercised on a bicycle ergometer at a workload corresponding to 40% of their maximal aerobic power (VO2max). The 11 healthy subjects exercised at a workload of 150 W. All subjects exercised for 60 min in ambient air at 35 degrees C, with 50% relative humidity. The P-test showed a mean day...

  13. Test plans for availability

    International Nuclear Information System (INIS)

    Rise, J.L.; Bjoerklund, O.

    1978-12-01

    In this work is developed principles for statistical test plans for availability compliance tests. Failure terminated and time terminated fixed size plans are considered as well as sequential test plans without and with failure and time truncation. The suggested methods are evaluated with respect to some important characteristics, namely the average number of failures to termination, the duration of the test and the operating characteristic function. The methods used are based on the assumption that up- and down-times can be considered gamma distributed. Simulation studies indicate that the methods are robust against reasonable deviations in distribution assumptions for the down-times. In the work is also outlined technical conditions and prerequisites applicable to availability compliance tests in general. The approach choosen seems very promising and is worth further development. It is based on the same fundamental principles as present is used in International standardization of equipment reliability testing. (author)

  14. Large scale model testing

    International Nuclear Information System (INIS)

    Brumovsky, M.; Filip, R.; Polachova, H.; Stepanek, S.

    1989-01-01

    Fracture mechanics and fatigue calculations for WWER reactor pressure vessels were checked by large scale model testing performed using large testing machine ZZ 8000 (with a maximum load of 80 MN) at the SKODA WORKS. The results are described from testing the material resistance to fracture (non-ductile). The testing included the base materials and welded joints. The rated specimen thickness was 150 mm with defects of a depth between 15 and 100 mm. The results are also presented of nozzles of 850 mm inner diameter in a scale of 1:3; static, cyclic, and dynamic tests were performed without and with surface defects (15, 30 and 45 mm deep). During cyclic tests the crack growth rate in the elastic-plastic region was also determined. (author). 6 figs., 2 tabs., 5 refs

  15. The engineering test facility

    International Nuclear Information System (INIS)

    Steiner, D.; Becraft, W.R.; Sager, P.H.

    1981-01-01

    The vehicle by which the fusion program would move into the engineering testing phase of fusion power development is designated the Engineering Test Facility (ETF). The ETF would provide a test-bed for reactor components in the fusion environment. In order to initiate preliminary planning for the ETF decision, the Office of Fusion Energy established the ETF Design Center activity to prepare the design of the ETF. This paper describes the design status of the ETF. (orig.)

  16. Engineering test facility

    International Nuclear Information System (INIS)

    Steiner, D.; Becraft, W.R.; Sager, P.H.

    1981-01-01

    The vehicle by which the fusion program would move into the engineering testing phase of fusion power development is designated the Engineering Test Facility (ETF). The ETF would provide a test-bed for reactor components in the fusion environment. In order to initiate preliminary planning for the ETF decision, the Office of Fusion Energy established the ETF Design Center activity to prepare the design of the ETF. This paper described the design status of the ETF

  17. Test planning and performance

    International Nuclear Information System (INIS)

    Zola, Maurizio

    2001-01-01

    Testing plan should include Safety guide Q4 - Inspection and testing - A testing plan should be prepared including following information: General information (facility name, item or system reference, procurement document reference, document reference number and status, associated procedures and drawings); A sequential listing of all testing activities; Procedure, work instruction, specification or standard to be followed in respect of each operation and test; Acceptance criteria; Identification of who is performing tests; Identification of hold points; Type of records to be prepared for each test; Persons and organizations having authority for final acceptance. Proposed activities sequence is: visual, electrical and mechanical checks; environmental tests (thermal aging, vibrations aging, radioactive aging); performance evaluation in extreme conditions; dynamic tests with functional checks; final electrical and mechanical checks The planning of the tests should always be performed taking into account an interpretative model: a very tight cooperation is advisable between experimental people and numerical people dealing with the analysis of more or less complex models for the seismic assessment of structures and components. Preparatory phase should include the choice of the following items should be agreed upon with the final user of the tests: Excitation points, Excitation types, Excitation amplitude with respect to frequency, Measuring points. Data acquisition, recording and storage, should take into account the characteristics of the successive data processing: to much data can be cumbersome to be processed, but to few data can make unusable the experimental results. The parameters for time history acquisition should be chosen taking into account data processing: for Shock Response Spectrum calculation some special requirements should be met: frequency bounded signal, high frequency sampling, shock noise. For stationary random-like excitation, the sample length

  18. Nondestructive testing method

    International Nuclear Information System (INIS)

    Porter, J.F.

    1996-01-01

    Nondestructive testing (NDT) is the use of physical and chemical methods for evaluating material integrity without impairing its intended usefulness or continuing service. Nondestructive tests are used by manufaturer's for the following reasons: 1) to ensure product reliability; 2) to prevent accidents and save human lives; 3) to aid in better product design; 4) to control manufacturing processes; and 5) to maintain a uniform quality level. Nondestructive testing is used extensively on power plants, oil and chemical refineries, offshore oil rigs and pipeline (NDT can even be conducted underwater), welds on tanks, boilers, pressure vessels and heat exchengers. NDT is now being used for testing concrete and composite materials. Because of the criticality of its application, NDT should be performed and the results evaluated by qualified personnel. There are five basic nondestructive examination methods: 1) liquid penetrant testing - method used for detecting surface flaws in materials. This method can be used for metallic and nonmetallic materials, portable and relatively inexpensive. 2) magnetic particle testing - method used to detect surface and subsurface flaws in ferromagnetic materials; 3) radiographic testing - method used to detect internal flaws and significant variation in material composition and thickness; 4) ultrasonic testing - method used to detect internal and external flaws in materials. This method uses ultrasonics to measure thickness of a material or to examine the internal structure for discontinuities. 5) eddy current testing - method used to detect surface and subsurface flaws in conductive materials. Not one nondestructive examination method can find all discontinuities in all of the materials capable of being tested. The most important consideration is for the specifier of the test to be familiar with the test method and its applicability to the type and geometry of the material and the flaws to be detected

  19. Biodiesel Test Plan

    Science.gov (United States)

    2014-07-01

    Biodiesel Test Plan Distribution Statement A: Approved for Public Release; distribution is unlimited. July 2014 Report No. CG-D-07-14...Appendix C) Biodiesel Test Plan ii UNCLAS//Public | CG-926 R&DC | G. W. Johnson, et al. Public | July 2014 N O T I C E This...Development Center 1 Chelsea Street New London, CT 06320 Biodiesel Test Plan iii UNCLAS//Public | CG-926 R&DC | G. W. Johnson, et al

  20. Dryden Aeronautical Test Range

    Data.gov (United States)

    Federal Laboratory Consortium — Recently redesignated to honor Dr. Hugh L. Dryden, NASA's Dryden Aeronautical Test Range (DATR) supports aerospace flight research and technology integration, space...

  1. GRE physics test

    CERN Document Server

    Fakhrudin, Hasan

    2010-01-01

    Designed for students and professionals looking to advance their careers, our test prep gives you everything you need to succeed. Focused chapter reviews cover all the information tested on the GRE Physics exam. Each review chapter contains examples to reinforce key concepts. The book includes four full-length practice tests based on the most recent GRE Physics exam. Each test contains every type of question that can be expected on the GRE so you can “practice for real” and boost your confidence before taking the exam.

  2. Cable tray fire tests

    International Nuclear Information System (INIS)

    Klamerus, L.J.

    1978-01-01

    Funds were authorized by the Nuclear Regulatory Commission to provide data needed for confirmation of the suitability of current design standards and regulatory guides for fire protection and control in water reactor power plants. The activities of this program through August 1978 are summarized. A survey of industry to determine current design practices and a screening test to select two cable constructions which were used in small scale and full scale testing are described. Both small and full scale tests to assess the adequacy of fire retardant coatings and full scale tests on fire shields to determine their effectiveness are outlined

  3. Calcium in Urine Test

    Science.gov (United States)

    ... K. Brunner & Suddarth's Handbook of Laboratory and Diagnostic Tests. 2 nd Ed, Kindle. Philadelphia: Wolters Kluwer Health, Lippincott Williams & Wilkins; c2014. Calcium, Serum; Calcium and Phosphates, Urine; ...

  4. Main Test Floor (MTF)

    Data.gov (United States)

    Federal Laboratory Consortium — Purpose: The MTF is employed to validate advanced structural concepts and verify new analytical methodologies. Test articles range in size from subcomponent to full...

  5. Cable aging tests

    International Nuclear Information System (INIS)

    Hubbard, G.

    1993-01-01

    This paper describes the results from aging, condition monitoring, and loss-of-coolant accident (LOCA) testing of class 1E electrical cables, per NUREG/CR-5772. This test was designed to test the performance of cables which had been aged with simultaneous radiation and thermal exposure. The tested cables included crosslinked polyolefin cables, ethylene propylene rubber cables, and miscellaneous cable types. Cables were exposed to 20, 40, and 60 years equivalent aging, and then exposed to LOCA tests at the end of their qualified life to determine the minimum insulation thickness needed for survival of the test. Failures were found in a large number of the tested cables. As a result the NRC has sent information notices to the industry regarding potential insulation problems. The results have raised the question of whether the artificial aging methods provide adequate testing methods. As a result of this testing the NRC is reviewing the artificial aging procedures, the adequacy of environmental qualification requirements for cable safety, and reexamining data from condition monitoring of installed cables

  6. Pavement Testing Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Comprehensive Environmental and Structural AnalysesThe ERDC Pavement Testing Facility, located on the ERDC Vicksburg campus, was originally constructed to provide an...

  7. Fire test database

    International Nuclear Information System (INIS)

    Lee, J.A.

    1989-01-01

    This paper describes a project recently completed for EPRI by Impell. The purpose of the project was to develop a reference database of fire tests performed on non-typical fire rated assemblies. The database is designed for use by utility fire protection engineers to locate test reports for power plant fire rated assemblies. As utilities prepare to respond to Information Notice 88-04, the database will identify utilities, vendors or manufacturers who have specific fire test data. The database contains fire test report summaries for 729 tested configurations. For each summary, a contact is identified from whom a copy of the complete fire test report can be obtained. Five types of configurations are included: doors, dampers, seals, wraps and walls. The database is computerized. One version for IBM; one for Mac. Each database is accessed through user-friendly software which allows adding, deleting, browsing, etc. through the database. There are five major database files. One each for the five types of tested configurations. The contents of each provides significant information regarding the test method and the physical attributes of the tested configuration. 3 figs

  8. Large coil test facility

    International Nuclear Information System (INIS)

    Nelms, L.W.; Thompson, P.B.

    1980-01-01

    Final design of the facility is nearing completion, and 20% of the construction has been accomplished. A large vacuum chamber, houses the test assembly which is coupled to appropriate cryogenic, electrical, instrumentation, diagnostc systems. Adequate assembly/disassembly areas, shop space, test control center, offices, and test support laboratories are located in the same building. Assembly and installation operations are accomplished with an overhead crane. The major subsystems are the vacuum system, the test stand assembly, the cryogenic system, the experimental electric power system, the instrumentation and control system, and the data aquisition system

  9. Repetitive Rockfall Trajectory Testing

    Directory of Open Access Journals (Sweden)

    Axel Volkwein

    2018-03-01

    Full Text Available Numerical simulations of rockfall trajectories are a standard procedure for evaluating rockfall hazards. For these simulations, corresponding software codes must be calibrated and evaluated based on field data. This study addresses methods of repeatable rockfall tests, and investigates whether it is possible to produce traceable and statistically analysable data. A testing series is described extensively covering how to conduct rockfall experiments and how certain elements of rockfall trajectories can be measured. The tests use acceleration and rotation sensors inside test blocks, a system to determine block positions over time, surveying measurements, and video recordings. All systems are evaluated regarding their usability in the field and for analyses. The highly detailed description of testing methods is the basis for sound understanding and reproducibility of the tests. This article serves as a reference for future publications and other rockfall field tests, both as a guide and as a basis for comparisons. First analyses deliver information on runout with a shadow angle ranging between 21 and 45 degrees for a slope consisting of homogeneous soft soil. A digital elevation model of the test site as well as point clouds of the used test blocks are part of this publication.

  10. Sodium blood test

    Science.gov (United States)

    ... medicines that may affect the test. These include: Antibiotics Antidepressants Some high blood pressure medicines Lithium Nonsteroidal anti-inflammatory drugs (NSAIDs) Water pills (diuretics) DO NOT stop ...

  11. Charcoal filter testing

    Energy Technology Data Exchange (ETDEWEB)

    Lyons, J. [Nuclear Regulatory Commission, Washington, DC (United States)

    1997-08-01

    In this very brief, informal presentation, a representative of the US Nuclear Regulatory Commission outlines some problems with charcoal filter testing procedures and actions being taken to correct the problems. Two primary concerns are addressed: (1) the process to find the test method is confusing, and (2) the requirements of the reference test procedures result in condensation on the charcoal and causes the test to fail. To address these problems, emergency technical specifications were processed for three nuclear plants. A generic or an administrative letter is proposed as a more permanent solution. 1 fig.

  12. Forensic DNA testing.

    Science.gov (United States)

    Butler, John M

    2011-12-01

    Forensic DNA testing has a number of applications, including parentage testing, identifying human remains from natural or man-made disasters or terrorist attacks, and solving crimes. This article provides background information followed by an overview of the process of forensic DNA testing, including sample collection, DNA extraction, PCR amplification, short tandem repeat (STR) allele separation and sizing, typing and profile interpretation, statistical analysis, and quality assurance. The article concludes with discussions of possible problems with the data and other forensic DNA testing techniques.

  13. Designing and testing prototypes

    NARCIS (Netherlands)

    Vereijken, P.; Wijnands, F.; Stol, W.

    1995-01-01

    This second progress report focuses on designing a theoretical prototype by linking parameters to methods and designing the methods in this context until they are ready for initial testing. The report focuses also on testing and improving the prototype in general and the methods in particular until

  14. Ultrasonic weld testing.

    Science.gov (United States)

    1970-12-01

    The study was broken down into two phases. Phase I consisted of a laboratory investigation of test specimens to determine the reliability of the ultrasonic equipment and testing procedure. Phase II was a field study where the knowledge, skills and ab...

  15. Coaxial test fixture

    Science.gov (United States)

    Praeg, Walter F.

    1986-01-01

    An assembly is provided for testing one or more contact material samples in a vacuum environment. The samples are positioned as an inner conductive cylinder assembly which is mounted for reciprocal vertical motion as well as deflection from a vertical axis. An outer conductive cylinder is coaxially positioned around the inner cylinder and test specimen to provide a vacuum enclosure therefor. A power source needed to drive test currents through the test specimens is connected to the bottom of each conductive cylinder, through two specially formed conductive plates. The plates are similar in form, having a plurality of equal resistance current paths connecting the power source to a central connecting ring. The connecting rings are secured to the bottom of the inner conductive assembly and the outer cylinder, respectively. A hydraulic actuator is also connected to the bottom of the inner conductor assembly to adjust the pressure applied to the test specimens during testing. The test assembly controls magnetic forces such that the current distribution through the test samples is symmetrical and that contact pressure is not reduced or otherwise disturbed.

  16. Poppering the Newell Test

    NARCIS (Netherlands)

    Taatgen, Niels A.

    2003-01-01

    The Newell Test as it is proposed by Anderson & Lebiere (A&L) has the disadvantage of being too positivistic, stressing areas a theory should cover, instead of attempting to exclude false predictions. Nevertheless, Newell's list can be used as the basis for a more stringent test with a stress on the

  17. Gastrin: The Test

    Science.gov (United States)

    ... lab's website in order to provide you with background information about the test(s) you had performed. You will need to return ... underlying condition. Although gastrinomas are rare, more than half of them are cancerous and can spread to other parts of your ... Helicobacter pylori , Gastric Acid Conditions: Endocrine Syndromes Elsewhere ...

  18. Testing as social practice

    DEFF Research Database (Denmark)

    Kousholt, Kristine

    2016-01-01

    In this article, the author challenges the implicit assumptions of tests as a neutral tool for measuring the individual’s learning achievement. Instead, testing is explored as a social practice which becomes part of children’s conduct of everyday life. The theoretical foundation for the analysis...

  19. Loglinear Rasch model tests

    NARCIS (Netherlands)

    Kelderman, Hendrikus

    1984-01-01

    Existing statistical tests for the fit of the Rasch model have been criticized, because they are only sensitive to specific violations of its assumptions. Contingency table methods using loglinear models have been used to test various psychometric models. In this paper, the assumptions of the Rasch

  20. Vocational Aptitude Test

    Directory of Open Access Journals (Sweden)

    Candiasa I Made

    2018-01-01

    Full Text Available Test for measuring vocational aptitude has been formulated and validated. There are three main constructs involved in vocational aptitude test, which are individual characteristics, activities that are likely to be selected, and professions that tend to be idolized. Individual characteristics indicate the individuals talents, whereas the activity that tends to be chosen leads to student interest in the activity, and the intended profession gives clues about the capability of themselves to pursue the profession. Content validity test with Lawse technique yields content validity ratio (CVR for all items are in the range 0.82-0.94 and content validity index (CVI = 0.88. The construct validity test yields comparative fit index (CFI = 0.918 and chi square coefficient (χ2 = 5.85 with significance (p = 0.002. These findings indicate that the test is valid either by content or construct. Furthermore, the reliability test with Alpha Cronbach found the alpha coefficient (α = 0.82. Finally, it can be concluded that vocational aptitude test can be utilized for early identification of student vocational aptitude. The hope, the test can help students to choose the appropriate vocational school, in order to obtain the better learning outcomes.

  1. Planter unit test stand

    Science.gov (United States)

    A planter test stand was developed to evaluate individual row-crop metering units in early 2013. This test stand provided the ability to quantify actual seed metering in terms of population, seed spacing, skips, and multiples over a range of meter RPMs and vacuum pressures. Preliminary data has been...

  2. Testing object Interactions

    NARCIS (Netherlands)

    Grüner, Andreas

    2010-01-01

    In this thesis we provide a unit testing approach for multi-purposes object-oriented programming languages in the style of Java and C#. Our approach includes the definition of a test specification language which results from extending the programming language with new designated specification

  3. Inspection- and test arrangement

    International Nuclear Information System (INIS)

    Weber, R.; Gallwas, J.

    1980-01-01

    The ultrasonic testing equipment is located on a wagon that can be moved on a circular rail fixed below the bottom of the cylindrical pressure vessel. To compensate thermal expansions between ground and rail, this rail is provided on its outside with radial sticks that are embedded in braces. The braces themselves are connected with the bottom that has to be tested. (DG) [de

  4. ALP - blood test

    Science.gov (United States)

    ... Tissues with higher amounts of ALP include the liver, bile ducts, and bone. A blood test can be done ... and the A.D.A.M. Editorial team. Bile Duct Diseases Read more Bone Diseases Read more Liver Function Tests Read more A.D.A.M., ...

  5. Follow-Up Testing

    Science.gov (United States)

    ... second should occur after 1 year on the gluten-free diet. After that, a celiac should receive follow-up ... test result is straightforward—a celiac on the gluten-free diet should have a negative test. The numerical value ...

  6. CLEAR test facility

    CERN Multimedia

    Ordan, Julien Marius

    2017-01-01

    A new user facility for accelerator R&D, the CERN Linear Electron Accelerator for Research (CLEAR), started operation in August 2017. CLEAR evolved from the former CLIC Test Facility 3 (CTF3) used by the Compact Linear Collider (CLIC). The new facility is able to host and test a broad range of ideas in the accelerator field.

  7. Preparing for CLIC tests

    CERN Multimedia

    Laurent Guiraud

    1999-01-01

    The Canon 5 undergoes first brazing for preparation in the CLIC study at the CLIC Test Facility 2 (CTF2). This will test injection for a proposed linear collider that will further explore discoveries made at the LHC. Electric fields in the canon will boost electrons into the acceleration fields of the collider.

  8. Proficiency tests, Evaluating

    NARCIS (Netherlands)

    Cofino, W.P.; Molenaar, J.; Torfs, P.J.J.F.

    2017-01-01

    Marine monitoring programs provide data that are essential for marine management. The reliability of such data is underpinned by proficiency tests. In the context of Quasimeme, a proficiency testing program for the marine environment, a statistical model has been developed in 2000 to evaluate data

  9. Vitamin A Test

    Science.gov (United States)

    ... was last reviewed on October 21, 2015. This article was last modified on June 29, 2018. At a Glance Why Get Tested? To detect vitamin A deficiency or toxicity When To Get Tested? When you have symptoms suggesting a vitamin A deficiency or excess, or are at risk for a deficiency Sample ...

  10. Hepatitis B Test

    Science.gov (United States)

    ... Links Patient Resources For Health Professionals Subscribe Search Hepatitis B Testing Send Us Your Feedback Choose Topic At ... Known As HBV Tests Hep B anti-HBs Hepatitis B Surface Antibody HBsAg Hepatitis B Surface Antigen HBeAg ...

  11. Testing confectionary products

    International Nuclear Information System (INIS)

    Kumar, M.; Smith, I.H.

    1983-01-01

    Cream-filled cakes are tested by passing a #betta#-ray from a #betta#-particle source to a detector and checking the #betta#-particle count to indicate if the cakes have been correctly filled with cream. The presence of a cake to be tested is sensed by an optical detector and incorrectly filled cakes are removed by a plunger. (author)

  12. Testing and Inclusive Schooling

    DEFF Research Database (Denmark)

    Morin, Anne; Hamre, Bjørn; Ydesen, Christian

    Testing and Inclusive Schooling provides a comparative on seemingly incompatible global agendas and efforts to include all children in the general school system, Thus reducing exclusion. With an examination of the international testing culture and the politics of inclusion currently permeating...

  13. SNL Abuse Testing Manual.

    Energy Technology Data Exchange (ETDEWEB)

    Orendorff, Christopher [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Lamb, Joshua [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Steele, Leigh Anna Marie [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-07-01

    This report describes recommended abuse testing procedures for rechargeable energy storage systems (RESSs) for electric vehicles. This report serves as a revision to the FreedomCAR Electrical Energy Storage System Abuse Test Manual for Electric and Hybrid Electric Vehicle Applications (SAND2005-3123).

  14. National HIV Testing Day

    Centers for Disease Control (CDC) Podcasts

    Dr. Kevin A. Fenton, Director of CDC's National Center for HIV/AIDS, Viral Hepatitis, STD, and TB Prevention, discusses National HIV Testing Day, an annual observance which raises awareness of the importance of knowing one's HIV status and encourages at-risk individuals to get an HIV test.

  15. Test dig selv!

    DEFF Research Database (Denmark)

    Hølge-Hazelton, Bibi; Nielsen, Gregers; Langstrup, Henriette

    2011-01-01

    Teknologirådet omkring rapporten ”Test dig selv! – Vurderinger og anbefalinger vedrørende anvendelse medicinsk udstyr til selvtestning. Offentliggjort d. 25.10.11.......Teknologirådet omkring rapporten ”Test dig selv! – Vurderinger og anbefalinger vedrørende anvendelse medicinsk udstyr til selvtestning. Offentliggjort d. 25.10.11....

  16. Over the air test

    DEFF Research Database (Denmark)

    2015-01-01

    [1] This invention relates to over-the-air testing of a device in an anechoic chamber. In particular, the invention is suitable for simulating both uplink and downlink over-the-air communication with a device under test even when the anechoic chamber has different numbers of uplink and downlink...

  17. The scapular dyskinesis test

    DEFF Research Database (Denmark)

    Christiansen, David Høyrup; Møller, Anders Damgaard; Vestergaard, Jesper Medom

    2017-01-01

    tests with which to identify scapular dyskinesis. PURPOSE OF THE STUDY: To evaluate intrarater and interrater reliability and predictive value of the Scapular Dyskinesis Test (SDT) in patients with subacromial impingement syndrome. METHODS: Forty-five patients with subacromial impingement syndrome were...

  18. Testing of Mortar Systems

    Science.gov (United States)

    2010-03-11

    IEP /TDP) or Independent Assessment Plan (IAP), and the test item and the procedures as outlined in this TOP. The following must also be considered...Command DTIC = Defense Technical Information Center DTP = Detailed Test Plan IAP = Independent Assessment Plan IEP = Independent Evaluation Plan IPT

  19. Automate functional testing

    Directory of Open Access Journals (Sweden)

    Ramesh Kalindri

    2014-06-01

    Full Text Available Currently, software engineers are increasingly turning to the option of automating functional tests, but not always have successful in this endeavor. Reasons range from low planning until over cost in the process. Some principles that can guide teams in automating these tests are described in this article.

  20. Solenoid Testing Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Current Configuration: Accommodate a device under test up to 2.8 m diameter, 0.7 m height and 15,000 lbs. weight. Up to 10 g/s, 4.5 K helium flow. Up to 250 A test...

  1. Robust test limits

    NARCIS (Netherlands)

    Albers, Willem/Wim; Kallenberg, W.C.M.; Otten, G.D.

    1997-01-01

    Because of inaccuracies of the measurement process inspection of manufactured parts requires test limits which are more strict than the given specification limits. Test limits derived under the assumption of normality for product characteristics turn out to violate the prescribed bound on the

  2. What Is Stress Testing?

    Science.gov (United States)

    ... would during exercise. You can then have the stress test. The medicine may make you flushed and anxious, but the effects go away as soon as the test is over. The medicine also may give you a headache. While you're exercising or getting medicine to ...

  3. Prematurely terminated slug tests

    International Nuclear Information System (INIS)

    Karasaki, K.

    1990-07-01

    A solution of the well response to a prematurely terminated slug test (PTST) is presented. The advantages of a PTST over conventional slug tests are discussed. A systematized procedure of a PTST is proposed, where a slug test is terminated in the midpoint of the flow point, and the subsequent shut-in data is recorded and analyzed. This method requires a downhole shut-in device and a pressure transducer, which is no more than the conventional deep-well slug testing. As opposed to slug tests, which are ineffective when a skin is present, more accurate estimate of formation permeability can be made using a PTST. Premature termination also shortens the test duration considerably. Because in most cases no more information is gained by completing a slug test to the end, the author recommends that conventional slug tests be replaced by the premature termination technique. This study is part of an investigation of the feasibility of geologic isolation of nuclear wastes being carried out by the US Department of Energy and the National Cooperative for the Storage of Radioactive Waste of Switzerland

  4. Chemical Reactivity Test (CRT)

    Energy Technology Data Exchange (ETDEWEB)

    Zaka, F. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-12-13

    The Chemical Reactivity Test (CRT) is used to determine the thermal stability of High Explosives (HEs) and chemical compatibility between (HEs) and alien materials. The CRT is one of the small-scale safety tests performed on HE at the High Explosives Applications Facility (HEAF).

  5. Parent's Guide to Understanding Tests.

    Science.gov (United States)

    CTB / McGraw-Hill, Monterey, CA.

    This brief introduction to testing is geared to parents. Types of tests are defined, such as standardized tests, achievement tests, norm referenced tests, criterion referenced tests, and aptitude tests. Various types of scores (grade equivalent, percentile rank, and stanine are also defined, and the uses made of tests by administrators, teachers,…

  6. Thermal Testing Measurements Report

    Energy Technology Data Exchange (ETDEWEB)

    R. Wagner

    2002-09-26

    The purpose of the Thermal Testing Measurements Report (Scientific Analysis Report) is to document, in one report, the comprehensive set of measurements taken within the Yucca Mountain Project Thermal Testing Program since its inception in 1996. Currently, the testing performed and measurements collected are either scattered in many level 3 and level 4 milestone reports or, in the case of the ongoing Drift Scale Test, mostly documented in eight informal progress reports. Documentation in existing reports is uneven in level of detail and quality. Furthermore, while all the data collected within the Yucca Mountain Site Characterization Project (YMP) Thermal Testing Program have been submitted periodically to the Technical Data Management System (TDMS), the data structure--several incremental submittals, and documentation formats--are such that the data are often not user-friendly except to those who acquired and processed the data. The documentation in this report is intended to make data collected within the YMP Thermal Testing Program readily usable to end users, such as those representing the Performance Assessment Project, Repository Design Project, and Engineered Systems Sub-Project. Since either detailed level 3 and level 4 reports exist or the measurements are straightforward, only brief discussions are provided for each data set. These brief discussions for different data sets are intended to impart a clear sense of applicability of data, so that they will be used properly within the context of measurement uncertainty. This approach also keeps this report to a manageable size, an important consideration because the report encompasses nearly all measurements for three long-term thermal tests. As appropriate, thermal testing data currently residing in the TDMS have been reorganized and reformatted from cumbersome, user-unfriendly Input-Data Tracking Numbers (DTNs) into a new set of Output-DTNs. These Output-DTNs provide a readily usable data structure

  7. Testing for Chronic Diarrhea.

    Science.gov (United States)

    Raman, M

    Chronic diarrhea is a frequently encountered symptom in clinical practice. The etiologies for chronic diarrhea are diverse and broad with varying clinical implications. A useful method of categorizing chronic diarrhea to guide a diagnostic work-up is a pathophysiology-based framework. Chronic diarrhea may be categorized as malabsorptive, secretory, osmotic, and inflammatory or motility related. Frequently, overlap between categories may exist for any given diarrhea etiology and diagnostic testing must occur with an understanding of the differential diagnosis. Investigations to achieve a diagnosis for chronic diarrhea range from screening blood and stool tests to more directed testing such as diagnostic imaging, and endoscopic and histological evaluation. The pathophysiology-based framework proposed in this chapter will allow the clinician to select screening tests followed by targeted tests to minimize cost and complications to the patient, while providing a highly effective method to achieve an accurate diagnosis. © 2017 Elsevier Inc. All rights reserved.

  8. LHC synchronization test successful

    CERN Multimedia

    The synchronization of the LHC's clockwise beam transfer system and the rest of CERN's accelerator chain was successfully achieved last weekend. Tests began on Friday 8 August when a single bunch of a few particles was taken down the transfer line from the SPS accelerator to the LHC. After a period of optimization, one bunch was kicked up from the transfer line into the LHC beam pipe and steered about 3 kilometres around the LHC itself on the first attempt. On Saturday, the test was repeated several times to optimize the transfer before the operations group handed the machine back for hardware commissioning to resume on Sunday. The anti-clockwise synchronization systems will be tested over the weekend of 22 August.Picture:http://lhc-injection-test.web.cern.ch/lhc-injection-test/

  9. Equipment for hydraulic testing

    International Nuclear Information System (INIS)

    Jacobsson, L.; Norlander, H.

    1981-07-01

    Hydraulic testing in boreholes is one major task of the hydrogeological program in the Stripa Project. A new testing equipment for this purpose was constructed. It consists of a downhole part and a surface part. The downhole part consists of two packers enclosing two test-sections when inflated; one between the packers and one between the bottom packer and the bottom of the borehole. A probe for downhole electronics is also included in the downhole equipment together with electrical cable and nylon tubing. In order to perform shut-in and pulse tests with high accuracy a surface controlled downhole valve was constructed. The surface equipment consists of the data acquisition system, transducer amplifier and surface gauges. In the report detailed descriptions of each component in the whole testing equipment are given. (Auth.)

  10. Biocide patch tests

    DEFF Research Database (Denmark)

    Andersen, Klaus Ejner; Veien, Niels

    1985-01-01

    Routine patch testing with a series of 6 industrial biocides containing methylene-bis-thiocyanate (Cytox 3522), benzisothiazolin-3-one (BIT), chlorocresol (Preventol CMK), 2-n-octyl-4-isothiazolin-3-one (Kathon 893), polyhydroxymethylene monobenzylether (Preventol D2) or 1,3,5-tris (hydroxy......-ethyl) hexahydrotriazine (Grotan BK) was carried out in 6 Danish out-patient clinics to evaluate guinea pig allergy test results with the same compounds. A total of 1652 consecutive patients with dermatitis were tested. The usefulness of this patch test battery was limited. There were a few positive reactions to Cytox...... of male patients and atopics, but significant differences in the frequencies of occupational cases, hand eczemas, and leg ulcers/stasis dermatitis, indicating possible variations in referral patterns, use of patch tests, and/or environmental factors....

  11. Mechanical Testing of MLCCs

    Science.gov (United States)

    Teverovsky, Alexander A.

    2016-01-01

    Cracking of multilayer ceramic capacitors, MLCCs, remains a serious problem for space systems. This problem increases substantially for large size capacitors and in cases when manual soldering is involved or the system experiences mechanical shock or vibration. In any case, a fracture occurs when the sum of external and internal mechanical stresses exceeds the strength of the part. To reduce the probability of cracking, the level of stress should be reduced, e.g. by optimizing the assembly workmanship and rules for board design, and the strength of the parts increased by selecting the most mechanically robust capacitors. The latter might possibly be achieved by selecting MLCCs based on the in-situ measurements of mechanical characteristics using four types of tests: flexural strength, hardness, fracture toughness, and flex bend testing. Note that military specifications MIL-PRF-123 and MIL-PRF-55681 do not have requirements for mechanical testing of the parts. However, specifications for automotive industry components employ two types of mechanical tests: beam load (break strength) test per AEC-Q200-003 and board flex test per AEC-Q200-005. A recent military specification for thin dielectric capacitors, MIL-PRF-32535, has one mechanical test, board flex testing, that is similar to AEC-Q200-005. The purpose of this report was assessment of the efficiency of different mechanical tests for selection robust capacitors and comparison of mechanical characteristics of Base Metal Electrode (BME) and Precious Metal Electrode (PME) capacitors. The report has three parts related to the first three mechanical tests mentioned above.

  12. Flushable reagent stool blood test

    Science.gov (United States)

    Stool occult blood test - flushable home test; Fecal occult blood test - flushable home test ... This test is performed at home with disposable pads. You can buy the pads at the drug store without ...

  13. Repository simulation tests

    International Nuclear Information System (INIS)

    Wicks, G.G.; Bibler, N.E.; Jantzen, C.M.; Plodinec, M.J.

    1984-01-01

    The repository simulation experiments described in this paper are designed to assess the performance of SRP waste glass under the most realistic repository conditions that can be obtained in the laboratory. These tests simulate the repository environment as closely as possible and introduce systematically the variability of the geology, groundwater chemistry, and waste package components during the leaching of the waste glass. The tests evaluate waste form performance under site-specific conditions, which differ for each of the geologic repositories under consideration. Data from these experiments will aid in the development of a realistic source term that can describe the release of radionuclides from SRP waste glass as a component of proposed waste packages. Hence, this information can be useful to optimize waste package design for SRP waste glass and to provide data for predicting long-term performance and subsequent conformance to regulations. The repository simulation tests also help to bridge the gap in interpreting results derived from tests performed under the control of the laboratory to the uncertainity and variability of field tests. In these experiments, site-specific repository components and conditions are emphasized and only the site specific materials contact the waste forms. An important feature of these tests is that both actual and simulated waste glasses are tested identically. 7 figures, 2 tables

  14. Mathematics Admission Test Remarks

    Directory of Open Access Journals (Sweden)

    Ideon Erge

    2016-12-01

    Full Text Available Since 2014, there have been admission tests in mathematics for applicants to the Estonian University of Life Sciences for Geodesy, Land Management and Real Estate Planning; Civil Engineering; Hydraulic Engineering and Water Pollution Control; Engineering and Technetronics curricula. According to admission criteria, the test must be taken by students who have not passed the specific mathematics course state exam or when the score was less than 20 points. The admission test may also be taken by those who wish to improve their state exam score. In 2016, there were 126 such applicants of whom 63 took the test. In 2015, the numbers were 129 and 89 and in 2014 150 and 47 accordingly. The test was scored on scale of 100. The arithmetic average of the score was 30.6 points in 2016, 29.03 in 2015 and 18.84 in 2014. The test was considered to be passed with 1 point in 2014 and 20 points in 2015 and 2016. We analyzed test results and gave examples of problems which were solved exceptionally well or not at all.

  15. MXIbus data throughput tests

    International Nuclear Information System (INIS)

    Botlo, M.; Dunning, J.; Jagieski, M.; Miller, L.; Romero, A.

    1992-11-01

    A series of tests were conducted to evaluate data transfer rates using the MXIbus architecture. The tests were conducted by the DAQ group in the Physics Research Division. The MXIbus from National Instruments provides a multisystem extension interface bus. It allows multiple VME chassis to be networked. Other bus architectures that can participate in the network include VXIbus, IBM PC-AT bus, Sun Sbus, Mac NuBus and stand-alone instruments with the appropriate MXIbus adapter cards. From a functional standpoint the MXIbus provides the capability to enlarge the address space in a fashion that is transparent to the software application. The tests were designed to measure data throughput when using the MSIbus with other industry off-the-shelf hardware. This report contains discussions on: MXIbus architecture and general guidelines; the commercial hardware and software used in each set of tests; and a brief description of each set of tests, observations and guidelines; the commercial hardware and software used in each set of tests; and a brief description of each set of tests, observations and conclusions

  16. Invalid Permutation Tests

    Directory of Open Access Journals (Sweden)

    Mikel Aickin

    2010-01-01

    Full Text Available Permutation tests are often presented in a rather casual manner, in both introductory and advanced statistics textbooks. The appeal of the cleverness of the procedure seems to replace the need for a rigorous argument that it produces valid hypothesis tests. The consequence of this educational failing has been a widespread belief in a “permutation principle”, which is supposed invariably to give tests that are valid by construction, under an absolute minimum of statistical assumptions. Several lines of argument are presented here to show that the permutation principle itself can be invalid, concentrating on the Fisher-Pitman permutation test for two means. A simple counterfactual example illustrates the general problem, and a slightly more elaborate counterfactual argument is used to explain why the main mathematical proof of the validity of permutation tests is mistaken. Two modifications of the permutation test are suggested to be valid in a very modest simulation. In instances where simulation software is readily available, investigating the validity of a specific permutation test can be done easily, requiring only a minimum understanding of statistical technicalities.

  17. Eco-Test at Vehicle Testing Centres

    Directory of Open Access Journals (Sweden)

    Nada Štrumberger

    2003-09-01

    Full Text Available Following the world conference on sustainable developmentof ecology, the care for the environment has to be strictlycomplied with, and this should be the task both of every individualand of the society as an organised whole. The work presentsconcrete measurements from practice and the indicators of thesituation regarding motor vehicles in Croatia. The EGO-TESThas been performed in Croatia according to the European Uniondirectives; first on the vehicles with petrol engines. Now, it isstarting to be applied on the vehicles with Diesel engines as well.Compliance with the EGO TEST regarding motor vehicles inCroatia will take into consideration the guidelines provided bythe European Union and thus reduce the harm from exhaustgases and noise pollution, and increase the possibility of usingmotor vehicles in order to reduce the danger and increase thesafety on the roads by excluding old vehicles from traffic.

  18. Seroepidemiology of human brucellosis in nomads in a rural area of Iran

    Directory of Open Access Journals (Sweden)

    Ali Sharafi Chegeni

    2014-08-01

    Full Text Available Objective: To survey the seroprevalence of brucellosis among nomads in Shoulabad, Lorestan province, Iran. Methods: In this descriptive study, a total of 5 847 person took part by randomized cluster sampling and 312 of them with clinical feature of brucellosis were selected. The diagnosis of brucellosis was made with a standard tube agglutination test (STAT, Coombs test, and 2-mercaptoethanol (2ME test, and the results with titers equal 1:80 or more were considered positive. Results: The seroprevalnce of anti-Brucella titer was 29.5% for STAT, 29.9% for Coombs test and 21.1% for 2ME test. Overall, 92, 93 and 66 patients had titers of 1:80 or higher in STAT, Coombs test and 2ME test, respectively. Seroprevalence was more among males (54.3% than females (45.7%. There is statistical difference between seroprevalence of infection and age (P<0.05. Based on age group, 10-19 years age group was more affected (37%. Conclusions: This results confirmed the necessity of conducting comprehensive and scheduled program of seroprevalence survey, particularly in nomad area, which aims at reducing the incidence of brucellosis as well as to guide planning programs by decision makers to improve community health.

  19. Parallelize Automated Tests in a Build and Test Environment

    OpenAIRE

    Durairaj, Selva Ganesh

    2016-01-01

    This thesis investigates the possibilities of finding solutions, in order to reduce the total time spent for testing and waiting times for running multiple automated test cases in a test framework. The “Automated Test Framework”, developed by Axis Communications AB, is used to write the functional tests to test both hardware and software of a resource. The functional tests that tests the software is considered in this thesis work. In the current infrastructure, tests are executed sequentially...

  20. Software Testing as Science

    Directory of Open Access Journals (Sweden)

    Ingrid Gallesdic

    2013-06-01

    Full Text Available The most widespread opinion among people who have some connection with software testing is that this activity is an art. In fact, books have been published widely whose titles refer to it as art, role or process. But because software complexity is increasing every year, this paper proposes a new approach, conceiving the test as a science. This is because the processes by which they are applied are the steps of the scientific method: inputs, processes, outputs. The contents of this paper examines the similarities and test characteristics as science.

  1. Turbine Engine Testing.

    Science.gov (United States)

    1981-01-01

    English climate. (c) Functional Testing Functional testing is a ’catch all’ title for the multitude of tests required to examine and confirm or correct the...rage I I I , I ’s slot envs Atar ONK propulsent les Miraiges IV de la levce A~rientic Strat~giqiie l-vanlaisc, tanilis tilit leg mcters Atar 91K50 sent...moignent. Irtuwi Atar 9 ~K50 est tine version MANv~ du motenr Atar 9K proptilsant le hirdaceur vi1 *c ~Ik (lttur 11 et dest in 5 6qtiiper I ’avion polyvalent

  2. Instant testing with QUnit

    CERN Document Server

    Sheiko, Dmitry

    2013-01-01

    Filled with practical, step-by-step instructions and clear explanations for the most important and useful tasks. A concise guide full of step-by-step recipes to teach you how to perform automated testing using QUnit.""Instant Testing with QUnit"" is for anyone working with JavaScript who is looking for a powerful and easy-to-use testing framework. The reader does not need to know any particular framework, only the basic principles of JavaScript and HTML.

  3. Accelerated cyclic corrosion tests

    Directory of Open Access Journals (Sweden)

    Prošek T.

    2016-06-01

    Full Text Available Accelerated corrosion testing is indispensable for material selection, quality control and both initial and residual life time prediction for bare and painted metallic, polymeric, adhesive and other materials in atmospheric exposure conditions. The best known Neutral Salt Spray (NSS test provides unrealistic conditions and poor correlation to exposures in atmosphere. Modern cyclic accelerated corrosion tests include intermittent salt spray, wet and dry phases and eventually other technical phases. They are able to predict the material performance in service more correctly as documented on several examples. The use of NSS should thus be restricted for quality control.

  4. Progress test utopia.

    Science.gov (United States)

    van der Vleuten, Cees; Freeman, Adrian; Collares, Carlos Fernando

    2018-04-01

    This paper discusses the advantages of progress testing. A utopia is described where medical schools would work together to develop and administer progress testing. This would lead to a significant reduction of cost, an increase in the quality of measurement and phenomenal feedback to learner and school. Progress testing would also provide more freedom and resources for more creative in-school assessment. It would be an educationally attractive alternative for the creation of cognitive licensing exams. A utopia is always far away in the future, but by formulating a vision for that future we may engage in discussions on how to get there.

  5. Application testing with Capybara

    CERN Document Server

    Robbins, Matthew

    2013-01-01

    Start performing integration testing with Capybara immediately. This book will get you up and running quickly and assumes no knowledge or experience of the technology.This book is for developers and testers who have had some exposure to Ruby but who want to know how to test their applications using Capybara and its compatible drivers, such as Selenium-Webdriver and Rack-Test. The examples are deliberately kept simple and example HTML mark-up is always included so that you can copy the examples to practice and experiment on your own machine.

  6. Laboratory testing in hyperthyroidism.

    Science.gov (United States)

    Grebe, Stefan K G; Kahaly, George J

    2012-09-01

    The clinical diagnosis of hypo- or hyperthyroidism is difficult (full text available online: http://education.amjmed.com/pp1/272). Clinical symptoms and signs are often non-specific, and there is incomplete correlation between structural and functional thyroid gland changes. Laboratory testing is therefore indispensible in establishing the diagnosis of thyrotoxicosis. Similar considerations apply to treatment monitoring. Laboratory testing also plays a crucial role in establishing the most likely cause for a patient's hyperthyroidism. Finally, during pregnancy, when isotopic scanning is relatively contraindicated and ultrasound is more difficult to interpret, laboratory testing becomes even more important. Copyright © 2012. Published by Elsevier Inc.

  7. Thermal test options

    International Nuclear Information System (INIS)

    Koski, J.A.; Keltner, N.R.; Sobolik, K.B.

    1993-02-01

    Shipping containers for radioactive materials must be qualified to meet a thermal accident environment specified in regulations, such at Title 10, Code of Federal Regulations, Part 71. Aimed primarily at the shipping container design, this report discusses the thermal testing options available for meeting the regulatory requirements, and states the advantages and disadvantages of each approach. The principal options considered are testing with radiant heat, furnaces, and open pool fires. The report also identifies some of the facilities available and current contacts. Finally, the report makes some recommendations on the appropriate use of these different testing methods

  8. Reduction in language testing

    DEFF Research Database (Denmark)

    Dimova, Slobodanka; Jensen, Christian

    2013-01-01

    /video recorded speech samples and written reports produced by two experienced raters after testing. Our findings suggest that reduction or reduction-like pronunciation features are found in tested L2 speech, but whenever raters identify and comment on such reductions, they tend to assess reductions negatively......This study represents an initial exploration of raters' comments and actual realisations of form reductions in L2 test speech performances. Performances of three L2 speakers were selected as case studies and illustrations of how reductions are evaluated by the raters. The analysis is based on audio...

  9. GRE math tests

    CERN Document Server

    Kolby, Jeff

    2014-01-01

    Twenty-three GRE Math Tests! The GRE math section is not easy. There is no quick fix that will allow you to ""beat"" the section. But GRE math is very learnable. If you study hard and master the techniques in this book, your math score will improve--significantly! The GRE cannot be ""beaten."" But it can be mastered--through hard work, analytical thought, and by training yourself to think like a test writer. Many of the problems in this book are designed to prompt you to think like a test writer. For example, you will find ""Duals."" These are pairs of similar problems in which only one prop

  10. GTK beam test 2017

    CERN Document Server

    Vostinic, Snezana

    2017-01-01

    The GTK is in operation at NA62 since 2014 and is among the few silicon pixel detectors performing 4D tracking. This summer, a beam test was conducted to study the phenomena determining the detector time resolution. The project described here contributed to the beam test preparation, data taking and data analyses. One of the main goals of the test was to understand the weight field contribution to the detector time resolution. This field is distorting the signal pulse shape at the edge of the pixel. Hence, to study this effect, the position of the hits inside the pixel has to be determined. An external telescope was therefore used for this purpose.

  11. TestComplete cookbook

    CERN Document Server

    Alpaev, Gennadiy

    2013-01-01

    A practical cookbook, with a perfect package of simple, medium, and advanced recipes targeted at basic programmers as well as expert software testers, who will learn to create, manage, and run automated tests. It is packed with problem-solving recipes that are supported by simple examples.If you are a software tester or a programmer who is involved with testing automation using TestComplete, this book is ideal for you! You will be introduced to the very basics of using the tool, as well as polish any previously gained knowledge in using the tool. If you are already aware of programming basics,

  12. Inspection and test planning

    International Nuclear Information System (INIS)

    Miller, T.

    1980-01-01

    Purpose of Quality Plan - arrangement of all necessary tests or inspections as far as possible filted to certain components or systems. Subject of Quality Plan - precise determination of tests or inspections and - according to the actual safety significance - the certificates to be done. Disposition of Quality Plan - accommodation of tests to the actual state of fabrication. Application of Quality Plan - to any component or system that is regarded. Supervision of Employment - by authorized personnel of manufacturer, customer or authority providing exact employment of quality plan. Overservance of Instructions - certificates given by authorized personnel. (orig./RW)

  13. Allergy Skin Tests

    Science.gov (United States)

    ... and symptoms. Medications can interfere with results Before scheduling a skin test, bring your doctor a list ... of Privacy Practices Notice of Nondiscrimination Manage Cookies Advertising Mayo Clinic is a not-for-profit organization ...

  14. Creatinine urine test

    Science.gov (United States)

    Urine creatinine test ... Creatinine is a chemical waste product of creatine. Creatine is a chemical the body makes to supply ... done to see how well your kidneys work. Creatinine is removed by the body entirely by the ...

  15. Nitroblue tetrazolium test

    Science.gov (United States)

    ... infections. Normal value ranges may vary slightly from one lab to another. Talk to your doctor about the meaning of your test results. What Abnormal Results Mean If the sample does not change color when NBT is added, ...

  16. FTA-ABS test

    Science.gov (United States)

    ... Chernecky CC, Berger BJ, eds. Laboratory Tests and Diagnostic Procedures . 6th ed. St Louis, MO: Elsevier Saunders; 2013:533-534. Radolf JD, Tramont EC, Salazar JC. Syphilis ( Treponema pallidum ). In: Bennett JE, Dolin R, Blaser ...

  17. Test Your Sodium Smarts

    Science.gov (United States)

    ... You may be surprised to learn how much sodium is in many foods. Sodium, including sodium chloride ... foods with little or no salt. Test your sodium smarts by answering these 10 questions about which ...

  18. Penetration testing with Perl

    CERN Document Server

    Berdeaux, Douglas

    2014-01-01

    If you are an expert Perl programmer interested in penetration testing or information security, this guide is designed for you. However, it will also be helpful for you even if you have little or no Linux shell experience.

  19. CPK isoenzymes test

    Science.gov (United States)

    ... such as dexamethasone This list is not all-inclusive. How the Test will Feel You may feel ... Cardiology, Harborview Medical Center, University of Washington Medical School, Seattle, WA. Also reviewed by David Zieve, MD, ...

  20. Histoplasma skin test

    Science.gov (United States)

    Histoplasmosis skin test ... health care provider cleans an area of your skin, usually the forearm. An allergen is injected just below the cleaned skin surface. An allergen is a substance that causes ...

  1. Climatic Environmental Test Facilities

    Data.gov (United States)

    Federal Laboratory Consortium — RTTC has an extensive suite of facilities for supporting MIL-STD-810 testing, toinclude: Temperature/Altitude, Rapid Decompression, Low/High Temperature,Temperature...

  2. Testing strong interaction theories

    International Nuclear Information System (INIS)

    Ellis, J.

    1979-01-01

    The author discusses possible tests of the current theories of the strong interaction, in particular, quantum chromodynamics. High energy e + e - interactions should provide an excellent means of studying the strong force. (W.D.L.)

  3. Materials Test Station

    Data.gov (United States)

    Federal Laboratory Consortium — When completed, the Materials Test Station at the Los Alamos Neutron Science Center will meet mission need. MTS will provide the only fast-reactor-like irradiation...

  4. C-Peptide Test

    Science.gov (United States)

    ... insulin injections or an insulin pump; when your health practitioner suspects that you have insulin resistance ; when you have documented ... Preparation Needed? Fasting for 8 to 10 hours before blood testing ...

  5. Coagulation Factors Test

    Science.gov (United States)

    ... Blood Testing Alpha-1 Antitrypsin Alpha-fetoprotein (AFP) Tumor Marker AMAS Aminoglycoside Antibiotics Ammonia Amniocentesis Amylase ANCA/MPO/ ... Beta-2 Microglobulin Kidney Disease Beta-2 Microglobulin Tumor Marker Bicarbonate (Total CO2) Bilirubin Blood Culture Blood Gases ...

  6. ROSE MIU Testing

    Science.gov (United States)

    Austin, Rebekah

    2015-01-01

    Overview of work done by Rebekah Austin during Pathways Internship work tour. Describes ROSE MIU (Reconfigurable Operational Spacecraft for Science and Exploration Module Interface Unit) features and test plan.

  7. Creatine phosphokinase test

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003503.htm Creatine phosphokinase test To use the sharing features on this page, please enable JavaScript. Creatine phosphokinase (CPK) is an enzyme in the body. ...

  8. Final focus test beam

    International Nuclear Information System (INIS)

    1991-03-01

    This report discusses the following: the Final Focus Test Beam Project; optical design; magnets; instrumentation; magnetic measurement and BPM calibration; mechanical alignment and stabilization; vacuum system; power supplies; control system; radiation shielding and personnel protection; infrastructure; and administration

  9. Practical acoustic emission testing

    CERN Document Server

    2016-01-01

    This book is intended for non-destructive testing (NDT) technicians who want to learn practical acoustic emission testing based on level 1 of ISO 9712 (Non-destructive testing – Qualification and certification of personnel) criteria. The essential aspects of ISO/DIS 18436-6 (Condition monitoring and diagnostics of machines – Requirements for training and certification of personnel, Part 6: Acoustic Emission) are explained, and readers can deepen their understanding with the help of practice exercises. This work presents the guiding principles of acoustic emission measurement, signal processing, algorithms for source location, measurement devices, applicability of testing methods, and measurement cases to support not only researchers in this field but also and especially NDT technicians.

  10. Prenatal Genetic Diagnostic Tests

    Science.gov (United States)

    ... are available for many inherited disorders. The main disadvantage is that diagnostic testing carries a very small ... chromosomes, arranged in order of size. Microarray: A technology that examines all of a person’s genes to ...

  11. Newborn Screening Tests

    Science.gov (United States)

    ... don't have enough biotinidase, an enzyme that recycles biotin (a B vitamin) in the body. Biotinidase ... about additional tests: Do you have a family history of an inherited disorder? Have you previously given ...

  12. Dynamics test on structures

    International Nuclear Information System (INIS)

    De Canio, G.; Ranieri, N.

    2009-01-01

    Shake table tests allow to assess the effectiveness of technologies for structures protection from natural events such as earthquakes. The article summarizes the remarkable results of the most significant projects. [it

  13. AC Test Chambers

    Data.gov (United States)

    Federal Laboratory Consortium — The Psychrometric Test Chamber’s primary purpose is to evaluate the performance of split type central air conditioners and heat pumps in the cooling capacity range...

  14. Liver Function Tests

    Science.gov (United States)

    ... Liver Function Tests Clinical Trials Liver Transplant FAQs Medical Terminology Diseases of the Liver Alagille Syndrome Alcohol-Related ... the Liver The Progression of Liver Disease FAQs Medical Terminology HOW YOU CAN HELP Sponsorship Ways to Give ...

  15. Potassium Blood Test

    Science.gov (United States)

    ... K. Brunner & Suddarth's Handbook of Laboratory and Diagnostic Tests. 2 nd Ed, Kindle. Philadelphia: Wolters Kluwer Health, Lippincott Williams & Wilkins; c2014. Potassium, Serum; 426–27 p. Lab ...

  16. SP-100 Test Site

    International Nuclear Information System (INIS)

    Cox, C.M.; Mahaffey, M.K.; Miller, W.C.

    1988-01-01

    Preparatory activities are well under way at Hanford to convert the 309 Containment Building and its associated service wing to a 2.5 MWt nuclear test facility for the SP-100 Ground Engineering System (GES) test. Preliminary design is complete, encompassing facility modifications, a secondary heat transport system, a large vacuum system to enclose the high temperature reactor, a test assembly cell and handling system, control and data processing systems, and safety and auxiliary systems. The design makes extensive use of existing equipment to minimize technical risk and cost. Refurbishment of this equipment is 75% complete. The facility has been cleared of obstructing equipment from its earlier reactor test. Current activities are focusing on definitive design and preparation of the Preliminary Safety Analysis Report (PSAR) aimed at procurement and construction approvals and schedules to achieve reactor criticality by January 1992. 6 refs

  17. Tuberculin Skin Testing

    Science.gov (United States)

    ... Appendix 1 Appendix 2 Appendix 3 Interim Laboratory Biosafety Guidance for XDR Mycobacterium tuberculosis strains Data & Statistics ... The Mantoux tuberculin skin test (TST) is the standard method of determining whether a person is infected ...

  18. Concrete decontamination scoping tests

    International Nuclear Information System (INIS)

    Archibald, K.E.

    1995-01-01

    This report details the research efforts and scoping tests performed at the Idaho Chemical Process Plant using scabbling, chemical, and electro-osmotic decontamination techniques on radiologically contaminated concrete

  19. Methylmalonic Acid Test

    Science.gov (United States)

    ... Factor Antibody Iron Iron Tests JAK2 Mutation Kidney Stone Analysis Kidney Stone Risk Panel KRAS Mutation Lactate Lactate Dehydrogenase (LD) ... in Previous Reviews Clarke, W. and Dufour, D. R., Editors (2006). Contemporary Practice in Clinical Chemistry, AACC ...

  20. Lyme Disease Tests

    Science.gov (United States)

    ... Wu, A. (© 2006). Tietz Clinical Guide to Laboratory Tests, 4th Edition: Saunders Elsevier, St. Louis, MO. Pp 1538. Forbes, B. et. al. (© 2007). Bailey & Scott's Diagnostic Microbiology, 12th Edition: Mosby Elsevier Press, St. Louis, MO. ...

  1. Chickenpox and Shingles Tests

    Science.gov (United States)

    ... Wu, A. (© 2006). Tietz Clinical Guide to Laboratory Tests , Fourth Edition: Saunders Elsevier, St. Louis, MO. Pp 1623. Forbes, B. et. al. (© 2007). Bailey & Scott's Diagnostic Microbiology , Twelfth Edition: Mosby Elsevier Press, St. Louis, MO. ...

  2. ELECTROFORCE 3330 TEST SYSTEM

    Data.gov (United States)

    Federal Laboratory Consortium — The Bose Electroforce 3330 is a test system with an axial electromagnetic linear motor, a torsional motor, and an environmental chamber for high and low temperature...

  3. Manipulator comparative testing program

    International Nuclear Information System (INIS)

    Draper, J.V.; Handel, S.J.; Sundstrom, E.; Herndon, J.N.; Fujita, Y.; Maeda, M.

    1986-01-01

    The Manipulator Comparative Testing Program examined differences among manipulator systems from the United States and Japan. The manipulator systems included the Meidensha BILARM 83A, the Model M-2 of Central Research Laboratories Division of Sargent Industries (CRL), and the GCA Corporation PaR Systems Model 6000. The site of testing was the Remote Operations Maintenance Demonstration (ROMD) facility, operated by the Fuel Recycle Division in the Consolidated Fuel Reprocessing Program at the Oak Ridge National Laboratory (ORNL). In all stages of testing, operators using the CRL Model M-2 manipulator had consistently lower times to completion and error rates than they did using other machines. Performance was second best with the Meidensha BILARM 83A in master-slave mode. Performance with the BILARM in switchbox mode and the PaR 6000 manipulator was approximately equivalent in terms of criteria recorded in testing. These data show no impact of force reflection on task performance

  4. IPv6 Testing

    National Research Council Canada - National Science Library

    Landis, Christopher B

    2006-01-01

    .... The DoD is also forming working relationships to conduct testing and share information. IPv6 was developed to resolve the issues of IPv4, mainly the limited amount of addresses and lack of security...

  5. Five Common Glaucoma Tests

    Science.gov (United States)

    ... About Us Donate In This Section Five Common Glaucoma Tests en Español email Send this article to ... year or two after age 35. A Comprehensive Glaucoma Exam To be safe and accurate, five factors ...

  6. Get Tested for Glaucoma!

    Science.gov (United States)

    ... of this page please turn Javascript on. Feature: Glaucoma Get Tested for Glaucoma! Past Issues / Fall 2009 Table of Contents Taylor ... aoa.org/ When were you finally diagnosed with glaucoma? Not until 1969, after a game of basketball. ...

  7. Lepromin skin test

    Science.gov (United States)

    ... if left untreated. It is caused by Mycobacterium leprae bacteria. This test is a research tool that ... Renault CA, Ernst JD. Mycobacterium leprae (leprosy). In: Bennett ... Principles and Practice of Infectious Diseases, Updated Edition . ...

  8. Combustor Section Acoustic Test

    National Research Council Canada - National Science Library

    Swanson, Andrew

    2003-01-01

    .... Following successful coupon and subelement tests on laser welding of Inco 625 heat exchangers, a full-scale scramjet flowpath section was fabricated to more realistically demonstrate the viability of the design concept...

  9. HIV Resistance Testing

    Science.gov (United States)

    ... 14, 2016 Select a Language: Fact Sheet 126 HIV Resistance Testing WHAT IS RESISTANCE? HOW DOES RESISTANCE ... ARVs. If you miss doses of your medications, HIV will multiply more easily. More mutations will occur. ...

  10. Dementia: Diagnosis and Tests

    Science.gov (United States)

    ... our e-newsletter! Aging & Health A to Z Dementia Diagnosis & Tests If you or someone you care ... To determine whether an older adult might have dementia, a healthcare professional will: Ask about the person’s ...

  11. Automatic Test Systems Aquisition

    National Research Council Canada - National Science Library

    1994-01-01

    We are providing this final memorandum report for your information and use. This report discusses the efforts to achieve commonality in standards among the Military Departments as part of the DoD policy for automatic test systems (ATS...

  12. Combinatorial Testing for VDM

    DEFF Research Database (Denmark)

    Larsen, Peter Gorm; Lausdahl, Kenneth; Battle, Nick

    2010-01-01

    by forgotten preconditions as well as broken invariants and post-conditions. Trace definitions are defined as regular expressions describing possible sequences of operation calls, and are conceptually similar to UML sequence diagrams. In this paper we present a tool enabling test automation based on VDM traces......Abstract—Combinatorial testing in VDM involves the automatic generation and execution of a large collection of test cases derived from templates provided in the form of trace definitions added to a VDM specification. The main value of this is the rapid detection of run-time errors caused......, and explain how it is possible to reduce large collections of test cases in different ways. Its use is illustrated with a small case study....

  13. Accelerated test program

    Science.gov (United States)

    Ford, F. E.; Harkness, J. M.

    1977-01-01

    A brief discussion on the accelerated testing of batteries is given. The statistical analysis and the various aspects of the modeling that was done and the results attained from the model are also briefly discussed.

  14. Haptoglobin blood test

    Science.gov (United States)

    The haptoglobin blood test measures the level of haptoglobin in your blood. Haptoglobin is a protein produced by the liver. It attaches to a certain type of hemoglobin in the blood. Hemoglobin is a blood cell that carries oxygen.

  15. Testing existence of antigravity

    CERN Document Server

    Hajdukovic, D

    2006-01-01

    After a brief review of arguments in favor of antigravity (as gravitational repulsion between matter and antimatter) we present a simple idea for an experimental test using antiprotons. Different experimental realizations of the same basic idea are considered

  16. Platelet antibodies blood test

    Science.gov (United States)

    This blood test shows if you have antibodies against platelets in your blood. Platelets are a part of the blood ... Chernecky CC, Berger BJ. Platelet antibody - blood. In: Chernecky ... caused by platelet destruction, hypersplenism, or hemodilution. ...

  17. HIV Genotypic Resistance Testing

    Science.gov (United States)

    ... Disorders Fibromyalgia Food and Waterborne Illness Fungal Infections Gout Graves Disease Guillain-Barré Syndrome Hashimoto Thyroiditis Heart ... antiretroviral therapy (ART) drugs. The test analyzes the genes of the HIV strain infecting the person to ...

  18. Wind Tunnel Testing Facilities

    Data.gov (United States)

    Federal Laboratory Consortium — NASA Ames Research Center is pleased to offer the services of our premier wind tunnel facilities that have a broad range of proven testing capabilities to customers...

  19. Receiver Test Selection Criteria

    Science.gov (United States)

    2015-03-12

    The DOT requests that GPS manufacturers submit receivers for test in the following TWG categories: - Aviation (non-certified), cellular, general location/navigation, high precision, timing, networks, and space-based receivers - Each receiver should b...

  20. On Cooper's Nonparametric Test.

    Science.gov (United States)

    Schmeidler, James

    1978-01-01

    The basic assumption of Cooper's nonparametric test for trend (EJ 125 069) is questioned. It is contended that the proper assumption alters the distribution of the statistic and reduces its usefulness. (JKS)

  1. Hepatitis A Test

    Science.gov (United States)

    ... Links Patient Resources For Health Professionals Subscribe Search Hepatitis A Testing Send Us Your Feedback Choose Topic At ... IgG HAV-Ab total Anti-HAV Formal Name Viral Hepatitis A Antibody This article was last reviewed on ...

  2. Scheduling the powering tests

    CERN Document Server

    Barbero-Soto, E; Casas-Lino, M P; Fernandez-Robles, C; Foraz, K; Pojer, M; Saban, R; Schmidt, R; Solfaroli-Camillocci, M; Vergara-Fernandez, A

    2008-01-01

    The Large Hadron Collider is now entering in its final phase before receiving beam, and the activities at CERN between 2007 and 2008 have shifted from installation work to the commissioning of the technical systems ("hardware commissioning"). Due to the unprecedented complexity of this machine, all the systems are or will be tested as far as possible before the cool-down starts. Systems are firstly tested individually before being globally tested together. The architecture of LHC, which is partitioned into eight cryogenically and electrically independent sectors, allows the commissioning on a sector by sector basis. When a sector reaches nominal cryogenic conditions, commissioning of the magnet powering system to nominal current for all magnets can be performed. This paper briefly describes the different activities to be performed during the powering tests of the superconducting magnet system and presents the scheduling issues raised by co-activities as well as the management of resources.

  3. A1C Test

    Science.gov (United States)

    ... Testing Triglycerides Troponin Tryptase Tumor Markers Uric Acid Urinalysis Urine Albumin and Albumin/Creatinine Ratio Urine Culture ... referenced to an accepted laboratory method (National Glycohemoglobin Standardization Program certified) should be used for diagnostic or ...

  4. Lactic acid test

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003507.htm Lactic acid test To use the sharing features on this page, please enable JavaScript. Lactic acid is mainly produced in muscle cells and red ...

  5. Chloride test - blood

    Science.gov (United States)

    Serum chloride test ... A greater-than-normal level of chloride is called hyperchloremia. It may be due to: Carbonic anhydrase inhibitors (used to treat glaucoma) Diarrhea Metabolic acidosis Respiratory alkalosis (compensated) Renal ...

  6. Growth hormone test

    Science.gov (United States)

    ... is called acromegaly . In children it is called gigantism . Too little growth hormone can cause a slow ... growth due to excess GH during childhood, called gigantism. (A special test is done to confirm this ...

  7. [Alternatives to animal testing].

    Science.gov (United States)

    Fabre, Isabelle

    2009-11-01

    The use of alternative methods to animal testing are an integral part of the 3Rs concept (refine, reduce, replace) defined by Russel & Burch in 1959. These approaches include in silico methods (databases and computer models), in vitro physicochemical analysis, biological methods using bacteria or isolated cells, reconstructed enzyme systems, and reconstructed tissues. Emerging "omic" methods used in integrated approaches further help to reduce animal use, while stem cells offer promising approaches to toxicologic and pathophysiologic studies, along with organotypic cultures and bio-artificial organs. Only a few alternative methods can so far be used in stand-alone tests as substitutes for animal testing. The best way to use these methods is to integrate them in tiered testing strategies (ITS), in which animals are only used as a last resort.

  8. Airborne Test Bed Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Laboratory operates the main hangar on the Hanscom Air Force Base flight line. This very large building (~93,000sqft) accommodates the Laboratory's airborne test...

  9. Ouellette Thermal Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Thermal Test Facility is a joint Army/Navy state-of-the-art facility (8,100 ft2) that was designed to:Evaluate and characterize the effect of flame and thermal...

  10. Regeneration Study Test Data

    Data.gov (United States)

    U.S. Environmental Protection Agency — Data (2 excel files) consist of the analytical test results on water sample collected from the two adsorption media tanks of the arsenic removal system during the...

  11. Space Electronic Test Engineering

    Science.gov (United States)

    Chambers, Rodney D.

    2004-01-01

    The Space Power and Propulsion Test Engineering Branch at NASA Glenn Research center has the important duty of controlling electronic test engineering services. These services include test planning and early assessment of Space projects, management and/or technical support required to safely and effectively prepare the article and facility for testing, operation of test facilities, and validation/delivery of data to customer. The Space Electronic Test Engineering Branch is assigned electronic test engineering responsibility for the GRC Space Simulation, Microgravity, Cryogenic, and Combustion Test Facilities. While working with the Space Power and Propulsion Test Engineering Branch I am working on several different assignments. My primary assignment deals with an electrical hardware unit known as Sunny Boy. Sunny Boy is a DC load Bank that is designed for solar arrays in which it is used to convert DC power form the solar arrays into AC power at 60 hertz to pump back into the electricity grid. However, there are some researchers who decided that they would like to use the Sunny Boy unit in a space simulation as a DC load bank for a space shuttle or even the International Space Station hardware. In order to do so I must create a communication link between a computer and the Sunny Boy unit so that I can preset a few of the limits (such power, set & constant voltage levels) that Sunny Boy will need to operate using the applied DC load. Apart from this assignment I am also working on a hi-tech circuit that I need to have built at a researcher s request. This is a high voltage analog to digital circuit that will be used to record data from space ion propulsion rocket booster tests. The problem that makes building this circuit so difficult is that it contains high voltage we must find a way to lower the voltage signal before the data is transferred into the computer to be read. The solution to this problem was to transport the signal using infrared light which will lower

  12. Ignitron long pulse testing

    International Nuclear Information System (INIS)

    Bronner, G.; Murray, J.G.; Duritt, S.P.

    1975-01-01

    Tests were performed on three types of ignitrons at current levels of from 2500 to 5000 Amperes and conduction periods of up to 5 seconds. Both mechanical deterioration and changes in certain electrical static characteristics were observed and used as criteria for test terminations. Significant results were the selection of a moderately priced tube type for the PLT ohmic heating system and the choice of a conductor connection arrangement which extends tube life. (auth)

  13. Eddy current testing

    Energy Technology Data Exchange (ETDEWEB)

    Song, Sung Jin; Lee, Hyang Beom; Kim, Young Hwan [Soongsil Univ., Seoul (Korea, Republic of); Shin, Young Kil [Kunsan Univ., Gunsan (Korea, Republic of)

    2004-02-15

    Eddy current testing has been widely used for non destructive testing of steam generator tubes. In order to retain reliability in ECT, the following subjects were carried out in this study: numerical modeling and analysis of defects by using BC and RPC probes in SG tube, preparation of absolute coil impedance plane diagram by FEM. Signal interpretation of the eddy current signals obtained from nuclear power plants.

  14. Building 431 fire tests

    International Nuclear Information System (INIS)

    Alvares, N.J.; Beason, D.G.; Ford, H.W.; Magee, M.W.

    1977-01-01

    An extensive discussion of considerations for fire protection in the LLL mirror fusion test facility (MFTF) is presented. Because of the large volume and high bays of the building, sufficient data on fire detection is unavailable. Results of fire detection tests using controlled fire sources in the building are presented. Extensive data concerning the behavior of the building atmosphere are included. Candidate fire detection instrumentation and extinguishing systems for use in the building are briefly reviewed

  15. Eddy current testing

    International Nuclear Information System (INIS)

    Song, Sung Jin; Lee, Hyang Beom; Kim, Young Hwan; Shin, Young Kil

    2004-02-01

    Eddy current testing has been widely used for non destructive testing of steam generator tubes. In order to retain reliability in ECT, the following subjects were carried out in this study: numerical modeling and analysis of defects by using BC and RPC probes in SG tube, preparation of absolute coil impedance plane diagram by FEM. Signal interpretation of the eddy current signals obtained from nuclear power plants

  16. Nondestructive testing 89

    International Nuclear Information System (INIS)

    1989-01-01

    The proceedings contain 24 contributions, out of which 14 have been inputted in INIS. These deal with materials for nondestructive testing and various nondestructive testing systems, with the evaluation of radiograms and with the application of radiographic, ultrasonic and eddy current methods to the detection of defects in materials, to the inspection of nuclear reactor components and in other fields of technology. (B.S.)

  17. Bayesian Hypothesis Testing

    Energy Technology Data Exchange (ETDEWEB)

    Andrews, Stephen A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Sigeti, David E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-11-15

    These are a set of slides about Bayesian hypothesis testing, where many hypotheses are tested. The conclusions are the following: The value of the Bayes factor obtained when using the median of the posterior marginal is almost the minimum value of the Bayes factor. The value of τ2 which minimizes the Bayes factor is a reasonable choice for this parameter. This allows a likelihood ratio to be computed with is the least favorable to H0.

  18. Functional Task Test (FTT)

    Science.gov (United States)

    Bloomberg, Jacob J.; Mulavara, Ajitkumar; Peters, Brian T.; Rescheke, Millard F.; Wood, Scott; Lawrence, Emily; Koffman, Igor; Ploutz-Snyder, Lori; Spiering, Barry A.; Feeback, Daniel L.; hide

    2009-01-01

    This slide presentation reviews the Functional Task Test (FTT), an interdisciplinary testing regimen that has been developed to evaluate astronaut postflight functional performance and related physiological changes. The objectives of the project are: (1) to develop a set of functional tasks that represent critical mission tasks for the Constellation Program, (2) determine the ability to perform these tasks after space flight, (3) Identify the key physiological factors that contribute to functional decrements and (4) Use this information to develop targeted countermeasures.

  19. Extended Life Coolant Testing

    Science.gov (United States)

    2016-06-06

    number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. 1. REPORT DATE (DD-MM-YYYY) 06-06-2016 2. REPORT TYPE Interim Report 3. DATES COVERED ... Corrosion Testing of Traditional and Extended Life Coolants 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Hansen, Gregory A. T...providing vehicle specific coolants. Several laboratory corrosion tests were performed according to ASTM D1384 and D2570, but with a 2.5x extended time

  20. Phototube testing for CDF

    International Nuclear Information System (INIS)

    Devlin, T.; Cruz, J.; Joshi, U.; Kazlauskis, K.; Muehleisen, C.; Yang, T.S.; Nodulman, L.

    1988-01-01

    Photomultiplier tubes for the Collider Detector at Fermilab were subjected to preinstallation testing for stability, linearity and other properties. An apparatus is described which provided computer control of light sources, monitoring of environmental conditions and data logging of responses from up to 48 photomultipliers simultaneously. Statistical summaries of the test results are included for 1041 tubes for the central electromagnetic calorimeter and 687 tubes for the endwall hadron calorimeter. (orig.)

  1. National HIV Testing Day

    Centers for Disease Control (CDC) Podcasts

    2011-06-09

    Dr. Kevin A. Fenton, Director of CDC's National Center for HIV/AIDS, Viral Hepatitis, STD, and TB Prevention, discusses National HIV Testing Day, an annual observance which raises awareness of the importance of knowing one's HIV status and encourages at-risk individuals to get an HIV test.  Created: 6/9/2011 by National Center for HIV/AIDS, Viral Hepatitis, STD, and TB Prevention (NCHHSTP).   Date Released: 6/9/2011.

  2. Comparative Test Case Specification

    DEFF Research Database (Denmark)

    Kalyanova, Olena; Heiselberg, Per

    This document includes the specification on the IEA task of evaluation building energy simulation computer programs for the Double Skin Facades (DSF) constructions. There are two approaches involved into this procedure, one is the comparative approach and another is the empirical one. In the comp....... In the comparative approach the outcomes of different software tools are compared, while in the empirical approach the modelling results are compared with the results of experimental test cases. The comparative test cases include: ventilation, shading and geometry....

  3. Testing of Military Towbars

    Science.gov (United States)

    2016-09-28

    Sieve analysis data are recorded using DD Form 1206 and the grain size distribution - aggregate grading chart. DD Form 1207 will be used to present...606 28 September 2016 6 b. Design load. The amount of load that the towbar was designed for as predicted by analysis . The design load is to be...test. Performance tests required for a complete towing analysis include the following: (1) Physical Characteristics (TOP 02-2-5004). (2

  4. Mantoux Tuberculin Skin Test

    Centers for Disease Control (CDC) Podcasts

    2006-11-22

    Learn how to evaluate people for latent TB infection with the Mantoux tuberculin skin test. This podcast includes sections on administering and reading the Mantoux tuberculin skin test, the standard method for detecting latent TB infection since the 1930s.  Created: 11/22/2006 by National Center for HIV, STD and TB Prevention (NCHHSTP).   Date Released: 12/12/2006.

  5. First Stage Acceptance Test

    Science.gov (United States)

    1960-01-01

    This photograph shows the intense smoke and fire created by the five F-1 engines from a test firing of the Saturn V first stage (S-1C) in the S-1C test stand at the Marshall Space Flight Center. The towering 363-foot Saturn V was a multi-stage, multi-engine launch vehicle standing taller than the Statue of Liberty. Altogether, the Saturn V engines produced as much power as 85 Hoover Dams.

  6. Sparse matrix test collections

    Energy Technology Data Exchange (ETDEWEB)

    Duff, I.

    1996-12-31

    This workshop will discuss plans for coordinating and developing sets of test matrices for the comparison and testing of sparse linear algebra software. We will talk of plans for the next release (Release 2) of the Harwell-Boeing Collection and recent work on improving the accessibility of this Collection and others through the World Wide Web. There will only be three talks of about 15 to 20 minutes followed by a discussion from the floor.

  7. Automated Test Case Generation

    CERN Multimedia

    CERN. Geneva

    2015-01-01

    I would like to present the concept of automated test case generation. I work on it as part of my PhD and I think it would be interesting also for other people. It is also the topic of a workshop paper that I am introducing in Paris. (abstract below) Please note that the talk itself would be more general and not about the specifics of my PhD, but about the broad field of Automated Test Case Generation. I would introduce the main approaches (combinatorial testing, symbolic execution, adaptive random testing) and their advantages and problems. (oracle problem, combinatorial explosion, ...) Abstract of the paper: Over the last decade code-based test case generation techniques such as combinatorial testing or dynamic symbolic execution have seen growing research popularity. Most algorithms and tool implementations are based on finding assignments for input parameter values in order to maximise the execution branch coverage. Only few of them consider dependencies from outside the Code Under Test’s scope such...

  8. Proof tests on reliability

    International Nuclear Information System (INIS)

    Mishima, Yoshitsugu

    1983-01-01

    In order to obtain public understanding on nuclear power plants, tests should be carried out to prove the reliability and safety of present LWR plants. For example, the aseismicity of nuclear power plants must be verified by using a large scale earthquake simulator. Reliability test began in fiscal 1975, and the proof tests on steam generators and on PWR support and flexure pins against stress corrosion cracking have already been completed, and the results have been internationally highly appreciated. The capacity factor of the nuclear power plant operation in Japan rose to 80% in the summer of 1983, and considering the period of regular inspection, it means the operation of almost full capacity. Japanese LWR technology has now risen to the top place in the world after having overcome the defects. The significance of the reliability test is to secure the functioning till the age limit is reached, to confirm the correct forecast of deteriorating process, to confirm the effectiveness of the remedy to defects and to confirm the accuracy of predicting the behavior of facilities. The reliability of nuclear valves, fuel assemblies, the heat affected zones in welding, reactor cooling pumps and electric instruments has been tested or is being tested. (Kako, I.)

  9. Fission product separations testing

    Energy Technology Data Exchange (ETDEWEB)

    Bostick, D.A.; DePaoli, S.M. [Oak Ridge National Lab., TN (United States)

    1997-10-01

    The initial goal of this task is to adequately understand the treatment needs of the end user in treating contaminated wastewater. These needs are then incorporated into the evaluation of new treatment technologies for wastewater treatment. Pertinent information is than supplied to the end user so that they can select a preferred process to meet their waste treatment needs. New sorbent materials, ion-exchange materials, or other processes of interest to DOE`s Office of Environmental Restoration (EM-40) will be evaluated initially for the removal of {sup 90}Sr and {sup 137}Cs from groundwater and process wastewater. Laboratory studies will strive to obtain a quantitative understanding of the behavior of these new materials and to evaluate their sorption efficiency in reference to a standard benchmark treatment technique. Testing of the new materials will begin by conducting scoping tests where new treatment materials are compared with standard, commercially available materials in batch shaker tests. Experimental data for the most promising sorbents will then be fit to an equilibrium model so that nuclide sorption can be predicted for variable wastewater composition. Additional testing with actual wastewater will be conducted with two or three of the most effective treatment methods. Once batch testing of a treatment method is completed, dynamic column tests will be performed to validate the equilibrium sorption model and to obtain the defining column operating parameters for scaling up the technology.

  10. Terrestrial photovoltaic cell process testing

    Science.gov (United States)

    Burger, D. R.

    1985-01-01

    The paper examines critical test parameters, criteria for selecting appropriate tests, and the use of statistical controls and test patterns to enhance PV-cell process test results. The coverage of critical test parameters is evaluated by examining available test methods and then screening these methods by considering the ability to measure those critical parameters which are most affected by the generic process, the cost of the test equipment and test performance, and the feasibility for process testing.

  11. AFFTC Instruction 99-1, Test and Evaluation Test Plans

    National Research Council Canada - National Science Library

    Crane, Roger

    2002-01-01

    .... Test Information Sheets (TISs) are actually appendices to test plans and contain sufficient information for use by a flight test engineer to develop flight test cards and for management to discern the overall technical approach being taken...

  12. Virtual Sensor Test Instrumentation

    Science.gov (United States)

    Wang, Roy

    2011-01-01

    Virtual Sensor Test Instrumentation is based on the concept of smart sensor technology for testing with intelligence needed to perform sell-diagnosis of health, and to participate in a hierarchy of health determination at sensor, process, and system levels. A virtual sensor test instrumentation consists of five elements: (1) a common sensor interface, (2) microprocessor, (3) wireless interface, (4) signal conditioning and ADC/DAC (analog-to-digital conversion/ digital-to-analog conversion), and (5) onboard EEPROM (electrically erasable programmable read-only memory) for metadata storage and executable software to create powerful, scalable, reconfigurable, and reliable embedded and distributed test instruments. In order to maximize the efficient data conversion through the smart sensor node, plug-and-play functionality is required to interface with traditional sensors to enhance their identity and capabilities for data processing and communications. Virtual sensor test instrumentation can be accessible wirelessly via a Network Capable Application Processor (NCAP) or a Smart Transducer Interlace Module (STIM) that may be managed under real-time rule engines for mission-critical applications. The transducer senses the physical quantity being measured and converts it into an electrical signal. The signal is fed to an A/D converter, and is ready for use by the processor to execute functional transformation based on the sensor characteristics stored in a Transducer Electronic Data Sheet (TEDS). Virtual sensor test instrumentation is built upon an open-system architecture with standardized protocol modules/stacks to interface with industry standards and commonly used software. One major benefit for deploying the virtual sensor test instrumentation is the ability, through a plug-and-play common interface, to convert raw sensor data in either analog or digital form, to an IEEE 1451 standard-based smart sensor, which has instructions to program sensors for a wide variety of

  13. Endurance test of DUPIC irradiation test rig-003

    Energy Technology Data Exchange (ETDEWEB)

    Moon, J.S; Yang, M.S.; Lee, C.Y.; Ryu, J.S.; Jeon, H.G

    2001-04-01

    This report presents the pressure drop, vibration and endurance test results for DUPIC Irradiation Test Rig-003 which was design and fabricated by KAERI. From the pressure drop and vibration test results, it is verified that DUPIC Irradiation Test Rig-003 satisfied the limit conditions of HANARO. And, remarkable wear is not observed in DUPIC Irradiation Test Rig-003 during 40 endurance test days.

  14. Test report - caustic addition system operability test procedure

    International Nuclear Information System (INIS)

    Parazin, R.E.

    1995-01-01

    This Operability Test Report documents the test results of test procedure WHC-SD-WM-OTP-167 ''Caustic Addition System Operability Test Procedure''. The Objective of the test was to verify the operability of the 241-AN-107 Caustic Addition System. The objective of the test was met

  15. Simulator testing system (STS)

    International Nuclear Information System (INIS)

    Miller, V.N.

    1990-01-01

    In recent years there has been a greater demand placed on the capabilities and time usage of real-time nuclear plant simulators due to NRC, INPO and utilities requirements. The requirements applied to certification, new simulators, upgrades, modifications, and maintenance of the simulators vary; however, they all require the capabilities of the simulator to be tested whether it is for NRC 10CFR55.45b requirements, ATP testing of new simulators, ATP testing of upgrades with or without panels, adding software/hardware due to plant modifications, or analyzing software/hardware problems on the simulator. This paper describes the Simulator Testing System (STS) which addresses each one of these requirements placed on simulators. Special attention will be given to ATP testing of upgrades without the use of control room panels. The capabilities and applications of the four parts of STS which are the Display Control Software (DCS), Procedure Control Software (PCS), Display Generator Software (DGS) and the Procedure Generator Software (PGS) will be reviewed

  16. Appearance test device

    International Nuclear Information System (INIS)

    Watanabe, Tadao.

    1995-01-01

    The device of the present invention photographs glass solidification products of high level radioactive wastes by a camera to inspect the state for the surface of the glass solidification products. Namely, illumination light is irradiated to the surface of a material to be tested containing radioactive substances to photograph the surface to be tested and the photographed images are displayed. A photographing unit enhousing an illumination light source and the camera for photographing the surface to be detected is movable in the longitudinal direction of the object to be detected. A first reflector is disposed for reflecting the illumination light from the light source in a horizontal direction intersecting the longitudinal direction described above and reflecting the reflection light from the object to be tested to the camera. A second reflector is disposed to a position opposing to the end face of the object to be detected for entering the illumination light from the first reflector to the end face of the object to be tested and reflecting the reflection light from the end face of the object to be detected to the first reflector. In a device thus composed, the upper and lower end faces of the object to be tested can be illuminated and photographed without facing the photographing unit to the object to be inspected. (I.S.)

  17. The performance testing

    International Nuclear Information System (INIS)

    Mayr, A.

    1975-01-01

    Concerning the time-schedule of reactor performance tests they normally begin when suppliers or constructors have finished construction and made all necessary construction and coordinated tests. If the last-mentioned tests are conducted profoundly, they contribute substantially to a quick and simple carrying-out of the last performance tests and to the general quality of components and systems. At this stage all components of a system should be properly fixed, machinery, instruments and electrical components adjusted and calibrated, all set-points tested, electrical and other supply units in operation or ready to operate and all functions pretested. Just at this stage of the work most of the existing defects and failures of systems can be found. Remembering the fact that the difficulty of operation of complex systems results from detail problems, it is extremely useful to remove all things of this kind as soon as possible, at the latest at this time where it is done easily and normally quickly without influencing start-up-procedures of other systems or even of the total plant. (orig./TK) [de

  18. Decades of nuclear testing

    International Nuclear Information System (INIS)

    Miettinen, J.K.

    1995-01-01

    The United States carried out the world's first nuclear test in 1945. The test marked the beginning of an arms race between the great powers that lasted for decades. Innumerable nuclear test explosions were detonated to test and refine the weapons. The arms race picked up speed in the 1950s and culminated in 1958, when the United States detonated 77 and the Soviet Union 35 nuclear explosions. This was followed by the first pause in nuclear testing, brought about through the efforts of the Pugwash organisation consisting of the world's foremost scientists. Finland, too, received its share of the radioactive fallout coming from atmospheric nuclear explosions. Rain water samples have been studied for radioactivity in Finland since the mid-1950s. The first studies to determine the internal radiation doses caused by radioactive substances in man were conducted in the late 1950s by measuring cesium and strontium contents in grass and in milk. The efficiency of research and radiation monitoring improved in the 1960s, which was also a time when training in the sector developed rapidly. In consequence, when the accident in Chernobyl took place Finland had already gained valuable experience needed for rapid determination of unexpected fallout. (orig.) (3 figs.)

  19. Relays undergo seismic tests

    International Nuclear Information System (INIS)

    Burton, J.C.

    1977-01-01

    Utilities are required by the Nuclear Regulatory Commission to document that seismic vibration will not adversely affect critical electrical equipment. Seismic testing should be designed to determine the malfunction level (fragility testing). Input possibilities include a continuous sine, a decaying sine, a sine beat, random vibrations, and combinations of random vibrations and sine beat. The sine beat most accurately simulates a seismic event. Test frequencies have a broad range in order to accommodate a variety of relay types and cabinet mounting. Simulation of motion along three axes offers several options, but is best achieved by three in-phase single-axis vibration machines that are less likely to induce testing fatigue failure. Consensus on what constitutes relay failure favors a maximum two microsecond discontinuity. Performance tests should be conducted for at least two of the following: (1) nonoperating modes, (2) operating modes, or (3) the transition above the two modes, with the monitoring mode documented for all three. Results should specify a capability curve of maximum safe seismic acceleration and a graph plotting acceleration with sine-beat frequency

  20. Test Room Stability Plan

    International Nuclear Information System (INIS)

    1993-01-01

    This plan documents the combination of designs, installations, programs, and activities that ensures that the underground excavations at the Waste Isolation Pilot Plant (WIPP), in which transuranic (TRU) waste may be emplaced during the Test Phase, will remain sufficiently stable and safe during that time. The current ground support systems installed at the WIPP are the result of over ten years of data collection from hundreds of geomechanical instruments and thousands of hours of direct observation of the changing conditions of the openings. In addition, some of the world's most respected experts on salt rock mechanics have provided input in the design process and concurrence on the suitability of the final design. The general mine rockbolt pattern and the ground support system for the test rooms are designed to specifically address the fracture and deformation geometries observed today at the WIPP. After an introductory chapter, this plan describes the general underground design, then proceeds to an account of general ground support performance, and finally focuses on the details of the special test room ground support systems. One such system already installed in Room 1, Panel 1, is described in comprehensive detail. Other test rooms in Panel 1, whether full-size or smaller, will be equipped with systems that ensure stability to the same or equivalent extent. They will benefit from the experience gained in the first test room, which in turn benefitted from the data and knowledge accumulated during previous stages (e.g., the Site and Preliminary Design Validation program) of the project