WorldWideScience

Sample records for cooling mismatch tests

  1. Power-Cooling-Mismatch Test Series Test PCM-7. Experiment operating specifications. [PWR

    Energy Technology Data Exchange (ETDEWEB)

    Sparks, D.T.; Smith, R.H.; Stanley, C.J.

    1979-02-01

    The experiment operating specifications for the Power-Cooling-Mismatch (PCM) Test PCM-7 to be conducted in the Power Burst Facility are described. The PCM Test Series was designed on the basis of a parametric evaluation of fuel behavior response with cladding temperature, rod internal pressure, time in film boiling, and test rod power being the variable parameters. The test matrix, defined in the PCM Experiment Requirements Document (ERD), encompasses a wide range of situations extending from pre-CHF (critical heat flux) PCMs to long duration operation in stable film boiling leading to rod failure.

  2. 14 CFR 27.1043 - Cooling tests.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Cooling tests. 27.1043 Section 27.1043... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Cooling § 27.1043 Cooling tests. (a) General. For the tests... during the cooling tests must be of the minimum grade approved for the engines, and the mixture...

  3. 14 CFR 25.1043 - Cooling tests.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Cooling tests. 25.1043 Section 25.1043... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Cooling § 25.1043 Cooling tests. (a) General. Compliance... during the cooling tests must be the minimum grade approved for the engines, and the mixture...

  4. 14 CFR 29.1043 - Cooling tests.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Cooling tests. 29.1043 Section 29.1043... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Cooling § 29.1043 Cooling tests. (a) General. For the... (a)(1) of this section may exceed established limits. (3) The fuel used during the cooling tests...

  5. 14 CFR 23.1043 - Cooling tests.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Cooling tests. 23.1043 Section 23.1043... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Cooling § 23.1043 Cooling... established limits. (3) The fuel used during the cooling tests must be of the minimum grade approved for...

  6. Development of MisMatch Transmission Line (MMTL) system for ICH&CD test rig

    Science.gov (United States)

    Ajesh, P.; Jha, Akhil; Anand, Rohit; Harikrishna, JVS; Trivedi, Rajesh; Mukherjee, Aparajita

    2015-12-01

    India is responsible for delivery of 8+1(prototype) RF sources to ITER Organization. Each RF source will provide 2.5MW of RF power at 2 VSWR in the frequency range of 35 to 65MHz with other stringent specifications. To test the sources at full performance, India is developing unique 3MW test facility with variable load condition (up to VSWR 3.0 at any phase angle in between 0°-360°), consisting of high power 50 Ohm dummy load, phase shifter and stub. The combined assembly of phase shifter and stub is called MisMatch Transmission Line (MMTL) system. Detailed RF and thermal simulation of the MMTL system has been done as a part of developmental activity. Simulations predict maximum RF voltage and current in the MMTL system are 18kV and 400A, respectively. Thermal simulation shows that system can be operated at 1.7MW/CW/3VSWR without active cooling. A detailed design and initial test results of MMTL system considering RF & mechanical aspect for testing ITER ICRF sources is described in this paper.

  7. A match-mismatch test of a stage model of behaviour change in tobacco smoking

    NARCIS (Netherlands)

    Dijkstra, A; Conijn, B; De Vries, H

    2006-01-01

    Aims An innovation offered by stage models of behaviour change is that of stage-matched interventions. Match-mismatch studies are the primary test of this idea but also the primary test of the validity of stage models. This study aimed at conducting such a test among tobacco smokers using the Social

  8. A match-mismatch test of a stage model of behaviour change in tobacco smoking

    NARCIS (Netherlands)

    Dijkstra, A; Conijn, B; De Vries, H

    2006-01-01

    Aims An innovation offered by stage models of behaviour change is that of stage-matched interventions. Match-mismatch studies are the primary test of this idea but also the primary test of the validity of stage models. This study aimed at conducting such a test among tobacco smokers using the Social

  9. Performance testing of engineered corium cooling systems

    Energy Technology Data Exchange (ETDEWEB)

    Lomperski, S., E-mail: lomperski@anl.gov [Argonne National Laboratory, 9700 S. Cass Avenue, Argonne, IL 60439-4840 (United States); Farmer, M.T. [Argonne National Laboratory, 9700 S. Cass Avenue, Argonne, IL 60439-4840 (United States)

    2012-02-15

    Highlights: Black-Right-Pointing-Pointer Experiments tested two engineered corium cooling systems. Black-Right-Pointing-Pointer The systems passively inject water into corium from below. Black-Right-Pointing-Pointer These systems cool corium much faster than top flooding. - Abstract: The coolability of ex-vessel core debris continues to be an issue of concern in the realm of light water reactor safety. Extensive research into corium/concrete interaction phenomena has been unable to establish the certainty of melt quench and stabilization within the containment boundary for all credible cases of cooling restricted to top flooding. As a result, there has been continuing interest in engineered systems that can augment cooling. This paper describes the testing of two passive cooling concepts that inject water into corium from below via nozzles embedded within the basemat: one with porous concrete nozzles and the other with a type of composite nozzle. The latter supplements water injection with noncondensable gas to stabilize flow and suppress vapor explosions. Each test involved a 136 kg melt composed of 56/23/14 wt% UO{sub 2}/ZrO{sub 2}/siliceous concrete at an initial depth of 30 cm. The setup with the porous concrete nozzles successfully injected water into the melt at heads as low as 2.3 m. The composite nozzle test was partially successful, with three nozzles delivering coolant while a fourth was damaged by the melt and failed to inject water. The melts cooled twice as fast as similar ones tested in a top flooding configuration. These experiments confirmed earlier work at Forschungszentrum Karlsruhe and elsewhere indicating that cooling via bottom water injection is a particularly effective method for quenching ex-vessel corium melts.

  10. Preoperational test report, recirculation condenser cooling systems

    Energy Technology Data Exchange (ETDEWEB)

    Clifton, F.T.

    1997-11-04

    This represents a preoperational test report for Recirculation Condenser Systems, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The four system provide condenser cooling water for vapor space cooling of tanks AY1O1, AY102, AZ1O1, AZ102. Each system consists of a valved piping loop, a pair of redundant recirculation pumps, a closed-loop evaporative cooling tower, and supporting instrumentation; equipment is located outside the farm on concrete slabs. Piping is routed to the each ventilation condenser inside the farm via below-grade concrete trenches. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System.

  11. Ice slurry cooling development and field testing

    Energy Technology Data Exchange (ETDEWEB)

    Kasza, K.E. [Argonne National Lab., IL (United States); Hietala, J. [Northern States Power Co., Minneapolis, MN (United States); Wendland, R.D. [Electric Power Research Inst., Palo Alto, CA (United States); Collins, F. [USDOE, Washington, DC (United States)

    1992-07-01

    A new advanced cooling technology collaborative program is underway involving Argonne National Laboratory (ANL), Northern States Power (NSP) and the Electric Power Research Institute (EPRI). The program will conduct field tests of an ice slurry distributed load network cooling concept at a Northern States Power utility service center to further develop and prove the technology and to facilitate technology transfer to the private sector. The program will further develop at Argonne National Laboratory through laboratory research key components of hardware needed in the field testing and develop an engineering data base needed to support the implementation of the technology. This program will sharply focus and culminate research and development funded by both the US Department of Energy and the Electric Power Research Institute on advanced cooling and load management technology over the last several years.

  12. Ice slurry cooling development and field testing

    Energy Technology Data Exchange (ETDEWEB)

    Kasza, K.E. (Argonne National Lab., IL (United States)); Hietala, J. (Northern States Power Co., Minneapolis, MN (United States)); Wendland, R.D. (Electric Power Research Inst., Palo Alto, CA (United States)); Collins, F. (USDOE, Washington, DC (United States))

    1992-01-01

    A new advanced cooling technology collaborative program is underway involving Argonne National Laboratory (ANL), Northern States Power (NSP) and the Electric Power Research Institute (EPRI). The program will conduct field tests of an ice slurry distributed load network cooling concept at a Northern States Power utility service center to further develop and prove the technology and to facilitate technology transfer to the private sector. The program will further develop at Argonne National Laboratory through laboratory research key components of hardware needed in the field testing and develop an engineering data base needed to support the implementation of the technology. This program will sharply focus and culminate research and development funded by both the US Department of Energy and the Electric Power Research Institute on advanced cooling and load management technology over the last several years.

  13. Preoperational test report, recirculation condenser cooling systems

    Energy Technology Data Exchange (ETDEWEB)

    Clifton, F.T.

    1997-11-04

    This represents a preoperational test report for Recirculation Condenser Systems, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The four system provide condenser cooling water for vapor space cooling of tanks AY1O1, AY102, AZ1O1, AZ102. Each system consists of a valved piping loop, a pair of redundant recirculation pumps, a closed-loop evaporative cooling tower, and supporting instrumentation; equipment is located outside the farm on concrete slabs. Piping is routed to the each ventilation condenser inside the farm via below-grade concrete trenches. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System.

  14. 14 CFR 29.1045 - Climb cooling test procedures.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Climb cooling test procedures. 29.1045... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Cooling § 29.1045 Climb cooling test procedures. (a) Climb cooling tests must be conducted under this section for— (1) Category...

  15. Counter-Flow Cooling Tower Test Cell

    Directory of Open Access Journals (Sweden)

    Dvořák Lukáš

    2014-03-01

    Full Text Available The article contains a design of a functional experimental model of a cross-flow mechanical draft cooling tower and the results and outcomes of measurements. This device is primarily used for measuring performance characteristics of cooling fills, but with a simple rebuild, it can be used for measuring other thermodynamic processes that take part in so-called wet cooling. The main advantages of the particular test cell lie in the accuracy, size, and the possibility of changing the water distribution level. This feature is very useful for measurements of fills of different heights without the influence of the spray and rain zone. The functionality of this test cell has been verified experimentally during assembly, and data from the measurement of common film cooling fills have been compared against the results taken from another experimental line. For the purpose of evaluating the data gathered, computational scripts were created in the MATLAB numerical computing environment. The first script is for exact calculation of the thermal balance of the model, and the second is for determining Merkel’s number via Chebyshev’s method.

  16. Recommendations for J and CTOD testing of strength mismatched. GKSS and EDF view

    Energy Technology Data Exchange (ETDEWEB)

    Kocak, M.; Kim, Y.J.; Hornet, P

    1998-03-01

    Recommendations for toughness testing and evaluation procedures for weldments are given in this paper. For testing aspects, two testing methods are outlined, micro-flat tensile tests and the {delta}{sub 5} testing technique. The micro-flat tensile tests are extremely useful to measure tensile properties for the Heat Affected Zone (HAZ) of multipass welds and very thin weld regions such as laser beam or electron beam and it is rather universal. It can be applied to any type of test pieces as well as to structural components with surface breaking cracks. These two test methods can provide efficient tools for tensile and fracture testing of metallic materials joined by fusion welding technology including high power beam welding processes. For toughness evaluation aspects, the J estimation procedures for mismatched specimens are reviewed, including a summary of a new proposal for best estimates of the mismatch on the J integral. The new procedure covers not only weld metal cracks but also HAZ cracks. Finally some recommendations are given for further development. (author) 29 refs.

  17. Research on Test Unit for Determining Cooling Characteristics of Quenchants

    Institute of Scientific and Technical Information of China (English)

    LI Lin-lin; ZHANG Wei-min; CHEN Nai-lu; LIU Zhan-cang; LIU Yang

    2004-01-01

    According to ASTM Designation DXXXX Standard Test Method for Determination of Cooling Characteristics of Quenchants by Cooling Curve Analysis with Agitation (Drayton Unit), a test unit was designed using which the cooling characteristics of a quenchant at different flow rates and different temperatures can be determined. We discussed the effects of flow rate and temperature on cooling characteristics of fast speed quenching oil. The results show that this unit can be well used for determining cooling characteristics of quechants at different flow rates and different temperatures. At the same time our investigation can provide a reference to the establishment of a standard for determination of cooling characteristics of quenchants with agitation.

  18. Predictive genetic testing in children: constitutional mismatch repair deficiency cancer predisposing syndrome.

    Science.gov (United States)

    Bruwer, Zandrè; Algar, Ursula; Vorster, Alvera; Fieggen, Karen; Davidson, Alan; Goldberg, Paul; Wainwright, Helen; Ramesar, Rajkumar

    2014-04-01

    Biallelic germline mutations in mismatch repair genes predispose to constitutional mismatch repair deficiency syndrome (CMMR-D). The condition is characterized by a broad spectrum of early-onset tumors, including hematological, brain and bowel and is frequently associated with features of Neurofibromatosis type 1. Few definitive screening recommendations have been suggested and no published reports have described predictive testing. We report on the first case of predictive testing for CMMR-D following the identification of two non-consanguineous parents, with the same heterozygous mutation in MLH1: c.1528C > T. The genetic counseling offered to the family, for their two at-risk daughters, is discussed with a focus on the ethical considerations of testing children for known cancer-causing variants. The challenges that are encountered when reporting on heterozygosity in a child younger than 18 years (disclosure of carrier status and risk for Lynch syndrome), when discovered during testing for homozygosity, are addressed. In addition, the identification of CMMR-D in a three year old, and the recommended clinical surveillance that was proposed for this individual is discussed. Despite predictive testing and presymptomatic screening, the sudden death of the child with CMMR-D syndrome occurred 6 months after her last surveillance MRI. This report further highlights the difficulty of developing guidelines, as a result of the rarity of cases and diversity of presentation.

  19. Short-term pilot cooling tower tests

    Energy Technology Data Exchange (ETDEWEB)

    Suciu, D.F.; Miller, R.L.

    1980-01-01

    Two major problems are associated with the use of cooled geothermal water as coolant for the 5 MW(e) pilot plant at Raft River. They are: (1) a scaling potential owing to the chemical species present in solution, and (2) the corrosive nature of the geothermal water. Tests were conducted to obtain data so that methods can be devised to either reduce or eliminate effects from these problems. Data show that scaling can be prevented, but only by using a high concentration of dispersant. Pitting data, however, are not as conclusive and seem to indicate that pitting control cannot be realized, but this result cannot be substantiated without additional experimentation. Results also demonstrate that chromate can be removed by using either chemical destruction or ion exchange. Whichever method is used, EPA discharge limits for both chromate and zinc can be achieved. A preliminary economic analysis is presented.

  20. Test of Optical Stochastic Cooling in the IOTA Ring

    CERN Document Server

    Lebedev, V A; Zolotorev, M S

    2014-01-01

    A new 150 MeV electron storage ring is being built at Fermilab. The construction of a new machine pursues two goals: A test of highly non-linear integrable optics and a test of optical stochastic cooling. This paper discusses details of OSC arrangements, choice of major parameters of the cooling scheme and incoming experimental tests of the optical amplifier prototype which uses highly doped Ti-sapphire crystal as amplification medium.

  1. Test of Optical Stochastic Cooling in the IOTA Ring

    Energy Technology Data Exchange (ETDEWEB)

    Lebedev, V. A.; Tokpanov, Yu.; Zolotorev, M. S. [LBNL

    2013-09-26

    A new 150 MeV electron storage ring is being built at Fermilab. The construction of a new machine pursues two goals a test of highly non-linear integrable optics and a test of optical stochastic cooling. This paper discusses details of OSC arrangements, choice of major parameters of the cooling scheme and incoming experimental tests of the optical amplifier prototype which uses highly doped Ti-sapphire crystal as amplification medium.

  2. Differentiation of schizophrenia patients from healthy subjects by mismatch negativity and neuropsychological tests.

    Directory of Open Access Journals (Sweden)

    Yi-Ting Lin

    Full Text Available BACKGROUND: Schizophrenia is a heterogeneous disorder with diverse presentations. The current and the proposed DSM-V diagnostic system remains phenomenologically based, despite the fact that several neurobiological and neuropsychological markers have been identified. A multivariate approach has better diagnostic utility than a single marker method. In this study, the mismatch negativity (MMN deficit of schizophrenia was first replicated in a Han Chinese population, and then the MMN was combined with several neuropsychological measurements to differentiate schizophrenia patients from healthy subjects. METHODOLOGY/PRINCIPAL FINDINGS: 120 schizophrenia patients and 76 healthy controls were recruited. Each subject received examinations for duration MMN, Continuous Performance Test, Wisconsin Card Sorting Test, and Wechsler Adult Intelligence Scale Third Edition (WAIS-III. The MMN was compared between cases and controls, and important covariates were investigated. Schizophrenia patients had significantly reduced MMN amplitudes, and MMN decreased with increasing age in both patient and control groups. None of the neuropsychological indices correlated with MMN. Predictive multivariate logistic regression models using the MMN and neuropsychological measurements as predictors were developed. Four predictors, including MMN at electrode FCz and three scores from the WAIS-III (Arithmetic, Block Design, and Performance IQ were retained in the final predictive model. The model performed well in differentiating patients from healthy subjects (percentage of concordant pairs: 90.5%. CONCLUSIONS/SIGNIFICANCE: MMN deficits were found in Han Chinese schizophrenia patients. The multivariate approach combining biomarkers from different modalities such as electrophysiology and neuropsychology had a better diagnostic utility.

  3. Development and testing of the cooling coil cleaning end effector

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, K.I.; Mullen, O.D.; Powell, M.R.; Daly, D.S.; Engel, D.W.

    1997-09-30

    The Retrieval Process Development and Enhancement (KPD{ampersand}E) program has developed and tested an end effector to support the waste retrieval mission at the Idaho National Engineering and Environmental Laboratory (INEEL). The end effector was developed specifically to remove a sticky waste material from the cooling coils in the High Level Liquid Waste (HLLW) tank, and to vacuum up a sediment layer that has settled beneath the cooling coils. An extensive testing program was conducted in the hydraulic test bed (HTB) at the Pacific Northwest National Laboratory (PNNL) to evaluate the performance of the end effector under simulated in-tank conditions. A mock up of the cooling coils was installed in the test bed tank, and simulated waste materials were included to represent the sticky waste on the tubes and the particulate waste settled beneath them. The testing program focused on assessing long-duration mining strategies for cleaning the cooling coils and removing the particulate waste forms. The report describes the results of the end effector testing program at PNNL. Section 2 describes the physical characteristics of the HLLW tanks, including the layout of the cooling coils, and it also describes what is known of the waste forms in the tanks. Section 3 describes the cleaning and retrieval strategy that was used in developing the end effector design. Section 4 describes the cooling coil mockup in the hydraulic test bed. Section 5 discusses the rationale used in selecting the simulants for the tarry waste and particulate waste forms. Section 6 describes the tests that were performed to evaluate cleaning of the cooling coils and retrieval of the particulate simulant. Section 7 summarizes the cleaning and retrieval tests, assesses the relative importance of cleaning the cooling coils and retrieving the particulate waste, and suggests modifications that would simplify the end effector design.

  4. Testing aspects of advanced coherent electron cooling technique

    Energy Technology Data Exchange (ETDEWEB)

    Litvinenko, V.; Jing, Y.; Pinayev, I.; Wang, G.; Samulyak, R.; Ratner, D.

    2015-05-03

    An advanced version of the Coherent-electron Cooling (CeC) based on the micro-bunching instability was proposed. This approach promises significant increase in the bandwidth of the CeC system and, therefore, significant shortening of cooling time in high-energy hadron colliders. In this paper we present our plans of simulating and testing the key aspects of this proposed technique using the set-up of the coherent-electron-cooling proof-of-principle experiment at BNL.

  5. Preoperational test report, primary ventilation condenser cooling system

    Energy Technology Data Exchange (ETDEWEB)

    Clifton, F.T.

    1997-10-29

    This represents the preoperational test report for the Primary Ventilation Condenser Cooling System, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system uses a closed chilled water piping loop to provide offgas effluent cooling for tanks AY101, AY102, AZ1O1, AZ102; the offgas is cooled from a nominal 100 F to 40 F. Resulting condensation removes tritiated vapor from the exhaust stack stream. The piping system includes a package outdoor air-cooled water chiller with parallel redundant circulating pumps; the condenser coil is located inside a shielded ventilation equipment cell. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System.

  6. New Technique for Cryogenically Cooling Small Test Articles

    Science.gov (United States)

    Rodriquez, Karen M.; Henderson, Donald J.

    2011-01-01

    Convective heat removal techniques to rapidly cool small test articles to Earth-Moon L2 temperatures of 77 K were accomplished through the use of liquid nitrogen (LN2). By maintaining a selected pressure range on the saturation curve, test articles were cooled below the LN2 boiling point at ambient pressure in less than 30 min. Difficulties in achieving test pressures while maintaining the temperature tolerance necessitated a modification to the original system to include a closed loop conductive cold plate and cryogenic shroud

  7. Water-Cooled Components Testing Program. Water-cooled nozzle testing

    Energy Technology Data Exchange (ETDEWEB)

    1985-05-01

    This experimental program involving full-sized gas turbine components was directed towards investigating the nature, composition, and formation rates of the ash deposited on these components by the combustion of hot, minimally cleaned coal gas (MCCG) under actual operating environments. Fired combustion testing was performed using the hot coal gas generated by the fixed-bed coal gasifier in the GE/CRD Process Evaluation Facility (PEF). The hot gas was routed from the gasifier at approx.1000/sup 0/F to a hot cyclone for particulate removal, following which the gas was burned in the turbine simulator, a pressurized test rig. The cyclone was found to have an average particulate removal efficiency of approximately 98%. The concentration of total alkali in the fuel gas entering the turbine simulator was 0.3 to 0.6 ppM, half of which was water-soluble; this corresponds to 1 to 2 ppM in a liquid petroleum-based fuel. The ash content of the fuel gas was 9 to 16 ppM, which would correspond to 51 to 91 ppM of ash in a residual fuel oil, i.e., much lower than that usually found in the latter fuel. Very little ash was found to deposit on the water-cooled nozzle airfoils. Ash deposits on the airfoils were primarily PbSO/sub 4/ and Fe/sub 2/O/sub 3/, which proved to be readily removed by water washing. While the MCCG combustion process was satisfactory, testing indicated that a potential area of concern in burning hot MCCG fuel is the formation of carbonaceous deposits in the fuel nozzle and piping. Variations in operating parameters and procedures may be effective in avoiding such deposits. Test data and analysis thus provided clearer insight into the additional work needed to enable a gas turbine to utilize hot (>1000/sup 0/F), minimally cleaned coal gas fuel. Five problems are described. 5 refs., 82 figs., 26 tabs.

  8. Assessment of building cooling energy need through a quasi-steady state model: Simplified correlation for gain-loss mismatch

    Energy Technology Data Exchange (ETDEWEB)

    Corrado, V.; Fabrizio, E. [Dipartimento di Energetica (DENER), Politecnico di Torino, Torino (Italy)

    2007-07-01

    The objective of this work is to implement a simplified calculation procedure for building net energy need, based on a quasi-steady state model and on a monthly data set. In particular, it is intended to supply a formulation of the dynamic parameters and to adapt them to Italian climatic, typological, constructive and user data. The method was validated by determining the numerical correlations of the gain/loss utilization factor, through a comparison with a detailed building energy simulation software (EnergyPlus). The simulation was run on some test rooms defined by CEN (European Committee for Standardization) and on some real buildings that are representative of the Italian building stock, assuming weather data from different Italian locations (Torino, Roma, Palermo). The work shows that the accuracy of results is greatly affected by nonlinearities in the determination of the heat transfer and that the dynamic parameters are sensitive to some building features which are not taken into account in the CEN correlations. (author)

  9. High Temperature Gas-Cooled Test Reactor Options Status Report

    Energy Technology Data Exchange (ETDEWEB)

    Sterbentz, James William [Idaho National Lab. (INL), Idaho Falls, ID (United States); Bayless, Paul David [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-08-01

    Preliminary scoping calculations are being performed for a 100 MWt gas-cooled test reactor. The initial design uses standard prismatic blocks and 15.5% enriched UCO fuel. Reactor physics and thermal-hydraulics simulations have been performed to identify some reactor design features to investigate further. Current status of the effort is described.

  10. TESTING AND SIMULATION OF SOLID STATE HEATING AND COOLING

    Directory of Open Access Journals (Sweden)

    CHAKIB ALAOUI

    2011-02-01

    Full Text Available The latest model of solid state Peltier thermoelectric pumps was reviewed and improved. A heating-cooling chamber was designed and fabricated by using the Peltier modules, and its equivalent circuit was extracted and simulated. This chamber was tested under various values of input power in both cooling and heating modes of operations. The experimental results were compared with the proposed model. This model is proven to be accurate and can be extend to any Peltier based thermoelectric system for simulation, and can be used to simulated thermoelectric systems based on these modules.

  11. Performance test of solar-assisted ejector cooling system

    KAUST Repository

    Huang, Bin-Juine

    2014-03-01

    A solar-assisted ejector cooling/heating system (SACH-2k) is built and test result is reported. The solar-driven ejector cooling system (ECS) is connected in series with an inverter-type air conditioner (IAC). Several advanced technologies are developed in SACH-k2, including generator liquid level control in ECS, the ECS evaporator temperature control, and optimal control of fan power in cooling tower of ECS. From the field test results, the generator liquid level control performs quite well and keeps stable performance of ejector. The ECS evaporator temperature control also performs satisfactorily to keep ejector performance normally under low or fluctuating solar radiation. The fan power control system cooling tower performs stably and reduces the power consumption dramatically without affecting the ECS performance. The test results show that the overall system COPo including power consumptions of peripheral increases from 2.94-3.3 (IAC alone) to 4.06-4.5 (SACH-k2), about 33-43%. The highest COPo is 4.5. © 2013 Elsevier Ltd and IIR. All rights reserved.

  12. Model tests on cooling of gas turbine blades

    Energy Technology Data Exchange (ETDEWEB)

    Hosenfeld, H.G.; von Schwerdtner, O.A. (Kraftwerk Union A.G., Muelheim an der Ruhr (Germany, F.R.). Versuchswesen)

    1979-01-01

    The experimental handling of the blade cooling problems requires test facilities suited to each particular problem in order to obtain an independent variation of influence values. To carry out investigations with the high temperatures of the actual machine, however, would necessitate expenditure of time and money. Consideration of the Law of Similarity results in a reduction in temperature and pressure. A test arrangement is shown and typical results are explained by means of examples.

  13. Testing the transtheoretical model for fruit intake: comparing web-based tailored stage-matched and stage-mismatched feedback.

    Science.gov (United States)

    de Vet, Emely; de Nooijer, Jascha; de Vries, Nanne K; Brug, Johannes

    2008-04-01

    A match-mismatch test was conducted to test the transtheoretical model applied to fruit intake. Precontemplators and contemplators were randomly assigned to receive a web-based individualized precontemplation feedback (PCF), contemplation feedback (CF) or action feedback (AF) letter promoting fruit intake. Immediately and 1 week after reading this letter, post-test measures were obtained. Fruit intake increased significantly between pre- and post-test in contemplators, but not in precontemplators. No differences between the feedback conditions were found in fruit intake, stage progression, use or credibility of the feedback in precontemplators and contemplators. In precontemplators, also no differences between the conditions were found in personal relevance of the feedback. Contemplators, however, rated AF as more personally relevant than PCF or CF. To conclude, the present study failed to show superiority of stage-matched information in the promotion of fruit intake.

  14. High-Temperature Gas-Cooled Test Reactor Point Design

    Energy Technology Data Exchange (ETDEWEB)

    Sterbentz, James William [Idaho National Laboratory; Bayless, Paul David [Idaho National Laboratory; Nelson, Lee Orville [Idaho National Laboratory; Gougar, Hans David [Idaho National Laboratory; Kinsey, James Carl [Idaho National Laboratory; Strydom, Gerhard [Idaho National Laboratory; Kumar, Akansha [Idaho National Laboratory

    2016-04-01

    A point design has been developed for a 200 MW high-temperature gas-cooled test reactor. The point design concept uses standard prismatic blocks and 15.5% enriched UCO fuel. Reactor physics and thermal-hydraulics simulations have been performed to characterize the capabilities of the design. In addition to the technical data, overviews are provided on the technological readiness level, licensing approach and costs.

  15. Thermal Performance Testing of EMU and CSAFE Liquid Cooling Garments

    Science.gov (United States)

    Rhodes, Richard; Bue, Grant; Hakam, Mark; Radford, Tamara

    2013-01-01

    Future exploration missions require the development of a new liquid cooling garment (LCG) that offers greater system reliability, is more comfortable, and maximizes thermal performance. To inform the development of a future LCG a thermal performance test was conducted to evaluate three factors: (1) the effect of the thermal comfort undergarment (TCU) on tactile and thermal comfort, (2) the comparable thermal performance of an CSAFE developed engineering evaluation unit (EEU) LCG, which uses a commercial-off-the-shelf (COTS) wicking garment as the base, and (3) the performance of a torso or upper body only LCG configuration to evaluate a proposed auxiliary loop configuration. To evaluate the thermal performance of each configuration a metabolic suit test was conducted, utilizing suited subjects to generate metabolic heat by walking on a treadmill at various speeds. Three (3) test subjects of similar height and weight produced a metabolic load for five tests by either resting (300-600 BTU/hr), walking at a slow pace (1200 BTU/hr), and walking at a brisk pace (2200 BTU/hr). During the test, data was collected that would allow us to track the heat transfer to the LCG and ventilation system to determine the thermal performance of the LCG configurations. Four different test configurations were tested, with one configuration tested twice. The test results show that the CSAFE EEU LCG and EMU LCG had comparable performance. The testing also showed that an auxiliary loop LCG, sized similarly to the shirt-only configuration, should provide adequate cooling for contingency scenarios. Finally, the testing showed the previous analysis that assumed a UA deterioration from the TCU was too conservative and the TCU may prove to be acceptable for future development with additional analysis and testing.

  16. Fundamental tests of nature with cooled and stored exotic ions

    CERN Document Server

    CERN. Geneva

    2014-01-01

    The presentation will concentrate on recent applications with exciting results of Penning traps in atomic and nuclear physics with cooled and stored exotic ions. These are high-accuracy mass measurements of short-lived radionuclides, g-factor determinations of the bound-electron in highly-charged, hydrogen-like ions and g-factor measurements of the proton and antiproton. The experiments are dedicated, e.g., to astrophysics studies and to tests of fundamental symmetries in the case of mass measurements on radionuclides, and to the determination of fundamental constants and a CPT test in the case of the g-factor measurements.

  17. 77 FR 36014 - Initial Test Program of Emergency Core Cooling Systems for Boiling-Water Reactors

    Science.gov (United States)

    2012-06-15

    ... COMMISSION Initial Test Program of Emergency Core Cooling Systems for Boiling-Water Reactors AGENCY: Nuclear...-1277, ``Initial Test Program of Emergency Core Cooling Systems for Boiling- Water Reactors.'' This... testing features of emergency core cooling systems (ECCSs) for boiling-water reactors (BWRs). DATES...

  18. 78 FR 35330 - Initial Test Programs for Water-Cooled Nuclear Power Plants

    Science.gov (United States)

    2013-06-12

    ... COMMISSION Initial Test Programs for Water-Cooled Nuclear Power Plants AGENCY: Nuclear Regulatory Commission... revision to Regulatory Guide (RG), 1.68, ``Initial Test Programs for Water-Cooled Nuclear Power Plants... Initial Test Programs (ITPs) for light water cooled nuclear power plants. ADDRESSES: Please refer...

  19. Augmented dry cooling surface test program: analysis and experimental results

    Energy Technology Data Exchange (ETDEWEB)

    Parry, H.L.; MacGowan, L.J.; Kreid, D.K.; Wiles, L.E.; Faletti, D.W.; Johnson, B.M.

    1979-09-01

    Experiments were performed to assess the operating characteristics and potential performance of water-augmented dry cooling systems. The work was aimed at evaluating a deluged air-cooled HOETERV plate fin heat exchanger surface proposed for integrated dry/wet cooling systems and using test results to guide the development of a predictive analytical model. In the process, all-dry performance data were obtained for the HOETERV surface as well as for two Curtiss-Wright chipped fin surfaces. The dry heat transfer data indicate that a slotted Curtiss-Wright surface slightly outperforms the HOETERV and nonslotted Curtiss-Wright surfaces based on heat rejection rate per unit of fan power. However, all three surfaces are so close in performance that other factors, such as surface cost and piping and mounting costs, will probably determine which surface is preferred at a given installation. Comparisons of deluged HOETERV performance with dry HOETERV and Curtiss-Wright performance under prototypic conditions have established that deluging can provide considerable heat rejection enhancement, particularly at low ITD and low air humidity. A deluged HOETERV core operating at a 115/sup 0/F primary fluid temperature in 105/sup 0/F air at 10% relative humidity can reject over 7 times as much heat as a dry HOETERV core operating under the same conditions at the same air-side pressure drop. Deluged tests were performed to evaluate the effect of airflow rate, deluge flow rate and core tilt angle on performance. Both increased airflow and increased deluge flow increase both heat rejection rate and required fan power. Optimal airflow rate will thus be determined for a given location by the competing costs of heat exchanger surface area versus fan operation. Changes in core tilt angle from vertical to 16/sup 0/ from vertical have a negligible effect on performance.

  20. Thermal Performance Testing of EMU and OSS Liquid Cooling Garments

    Science.gov (United States)

    Rhodes, Richard; Bue, Grant; Hakam, Mary

    2012-01-01

    A test was conducted to evaluate three factors influencing the thermal performance of liquid cooling garments (LCG): (1) the comparable thermal performance of an Oceaneering developed engineering evaluation unit (EEU) prototype LDG, (2) the effect of the thermal comfort undergarment (TCU), and (3) the performance of a torso or upper body only LCG configuration. To evaluate the thermal performance of each configuration a metabolic test was conducted, utilizing suited subjects to generate the metabolic heat. For this study three (3) test subjects of similar health and weight produced a metabolic load on the LDG configuration by either resting (300-600 BTU/hr), walking at a slow pace (1200 BRU/hr), and walking at a brisk pace (2200 BTU/hr), as outlined in Figure 1, the metabolic profile. During the test, oxygen consumption, heart rate, relative humidity, air flow, inlet and outlet air pressure, inlet and outlet air temperature, delta air temperature, water flow (100 lb/hr), inlet water temperature (64 F), delta water temperature, water pressure, core body temperature, skin temperature, and sweat loss data was recorded. Four different test configurations were tested, with one configuration tested twice, as outlined in Table 1. The test was conducted with the suit subjects wearing the Demonstrator Suit, pressurized to vent pressure (approximately 0.5 psig). The demonstrator suit has an integrated ventilation duct system and was used to create a relevant environment with a captured ventilation return, an integrated vent tree, and thermal insulation from the environment.

  1. MISMATCH: A basis for semi-automatic functional mixed-signal test-pattern generation

    NARCIS (Netherlands)

    Kerkhoff, Hans G.; Tangelder, R.J.W.T.; Speek, Han; Engin, N.

    1996-01-01

    This paper describes a tool which assists the designer in the rapid generation of functional tests for mixed-signal circuits down to the actual test-signals for the tester. The tool is based on manipulating design data, making use of macro-based test libraries and tester resources provided by the

  2. Data on test results of vessel cooling system of high temperature engineering test reactor

    Energy Technology Data Exchange (ETDEWEB)

    Saikusa, Akio [Secretariat of Nuclear Safety Commission, Tokyo (Japan); Nakagawa, Shigeaki; Fujimoto, Nozomu; Tachibana, Yukio; Iyoku, Tatsuo [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment

    2003-02-01

    High Temperature Engineering Test Reactor (HTTR) is the first graphite-moderated helium gas cooled reactor in Japan. The rise-to-power test of the HTTR started on September 28, 1999 and thermal power of the HTTR reached its full power of 30 MW on December 7, 2001. Vessel Cooling System (VCS) of the HTTR is the first Reactor Cavity Cooling System (RCCS) applied for High Temperature Gas Cooled Reactors. The VCS cools the core indirectly through the reactor pressure vessel to keep core integrity during the loss of core flow accidents such as depressurization accident. Minimum heat removal of the VCS to satisfy its safety requirement is 0.3MW at 30 MW power operation. Through the performance test of the VCS in the rise-to-power test of the HTTR, it was confirmed that the VCS heat removal at 30 MW power operation was higher than 0.3 MW. This paper shows outline of the VCS and test results on the VCS performance. (author)

  3. Cooling performance test of the superconducting fault current limiter

    Energy Technology Data Exchange (ETDEWEB)

    Yeom, H.; Hong, Y. J.; Ko, J.; In, S.; Kim, H. B.; Park, S. J. [Korea Institute ofMachinery and Materials, Daejeon (Korea, Republic of); Kim, H.; Kim, H. R. [Korea Electric Power Corporation Research Institute, Daejeon (Korea, Republic of)

    2014-12-15

    The superconducting fault current limiter (SFCL) is an electrical power system device that detects the fault current automatically and limits the magnitude of the current below a certain safety level. The SFCL module does not have any electrical resistance below the critical temperature, which facilitates lossless power transmission in the electric power system. Once given the fault current, however, the superconducting conductor exhibits extremely high electrical resistance, and the magnitude of the current is accordingly limited to a low value. Therefore, SFCL should be maintained at a temperature below the critical temperature, which justifies the cryogenic cooling system as a mandatory component. This report is a study which reported on the cooling system for the 154 kV-class hybrid SFCL owned by Korea Electric Power Corporation (KEPCO). Using the cryocooler, the temperature of liquid nitrogen (LN2) was lowered to 71 K. The cryostat was pressurized to 5 bars to improve the dielectric strength of nitrogen and suppress nitrogen bubble foaming during operation of SFCL. The SFCL module was immersed in the liquid nitrogen of the cryostat to maintain the superconducting state. The performance test results of the key components such as cryocooler, LN2 circulation pump, cold box, and pressure builder are shown in this paper.

  4. Effect of Half Time Cooling on Thermoregulatory Responses and Soccer-Specific Performance Tests

    Directory of Open Access Journals (Sweden)

    Yang Zhang

    2014-03-01

    Full Text Available This study examined two active coolings (forearm and hand cooling, and neck cooling during a simulated half-time recovery on thermoregulatory responses and subsequent soccer-specific exercise performance. Following a 45-min treadmill run in the heat, participants (N=7 undertook 15-min recovery with either passive cooling, forearm and hand cooling, or neck cooling in a simulated cooled locker room environment. After the recovery, participants performed a 6×15-m sprint test and Yo-Yo Intermittent Recovery Level 1 test (YYIR1 in a temperate environment. During the 15-min recovery, rectal temperature fell significantly (p<0.05. Neither active coolings induced further reduction in rectal temperature compared to passive cooling. No effect of active coolings was found in repeated sprint test. However, neck cooling reduced (p<0.05 the thermal sensation (TS compared to passive cooling during the 15-min recovery. Active coolings attenuated (p<0.05 the sweat rate compared to passive cooling: 1.2±0.3 l•h-1 vs. 0.8±0.1 l•h-1 vs. 0.8±0.3 l•h-1, for passive cooling, forearm and hand cooling, and neck cooling, respectively. For passive cooling, elevated sweat rate resulted in higher (p<0.05 dehydration (2.1±0.3% compared to neck cooling (1.5±0.3% and forearm and hand cooling (1.4±0.3%. YYIR1 was improved (p<0.05 following forearm and hand cooling (869±320 m and neck cooling (814±328 m compared to passive cooling (654±311 m. Neck cooling (4.6±0.6 reduced (p=0.03 the session TS compared to passive cooling (5.3±0.5. These results suggest that active coolings effectively improved comfort and sweating response, which delayed exercise-heat induced performance diminish during a second bout of exercise.

  5. Test and evaluation of a solar-powered laboratory turbocompressor system for building heating and cooling. Final technical report. [Rankine cycle

    Energy Technology Data Exchange (ETDEWEB)

    Biancardi, F.R.; Meader, M.D. Melikian, G.; Landerman, A.M.; Hall, J.B.

    1977-03-01

    Extensive testing of an available laboratory Rankine-cycle turbocompressor cooling system was conducted over a range of temperatures consistent with present-day flat-plate and advanced medium-concentration solar collectors and at air- and water-cooled condenser temperature levels. Over 700 hours of testing demonstrated the high performance potential of such systems over a wide range of operational conditions and has provided design guidelines and preliminary specifications for future systems. Minor modifications were made to the laboratory system. These modifications included: (1) demonstration of three tons of cooling at a turbine inlet temperature of about 160 F, (2) efficient operation (i.e., COP of approximately 0.45) at turbine inlet temperatures of 240 F at air-cooled condenser temperatures, and (3) a COP in excess of 0.5 and more than five tons of cooling at system turbine inlet temperature levels of 200 F with water-cooled condenser temperatures. Generally, the test data correlated very well with detailed analytical design and off-design performance projections over the range of operating conditions. These data correlations indicate that the achieved performance levels were limited by mismatching of the existing turbomachinery elements. Data and experience obtained in this program substantiate the judgment that incorporating well-matched turbomachinery, based on existing technology, would result in the achievement of the full potential of a turbocompressor system for both air- and water-cooled operation. Prototype turbocompressor systems can be designed and developed which demonstrate high performance, (i.e., a COP approaching 1.0 and 0.75 for water and air-cooled operation, respectively), versatile operational features, permitting use of different collectors with a range of temperature capability, and potential for significant energy savings when used as solar-powered heating and cooling systems.

  6. ERP investigation of study-test background mismatch during face recognition in schizophrenia.

    Science.gov (United States)

    Guillaume, Fabrice; Guillem, François; Tiberghien, Guy; Stip, Emmanuel

    2012-01-01

    Old/new effects on event-related potentials (ERP) were explored in 20 patients with schizophrenia and 20 paired comparison subjects during unfamiliar face recognition. Extrinsic perceptual changes - which influence the overall familiarity of an item while retaining face-intrinsic features for use in structural face encoding - were manipulated between the study phase and the test. The question raised here concerns whether these perceptual incongruities would have a different effect on the sense of familiarity and the corresponding behavioral and ERP measures in the two groups. The results showed that schizophrenia patients were more inclined to consider old faces shown against a new background as distractors. This drop in face familiarity was accompanied by the disappearance of ERP old/new effects in this condition, i.e., FN400 and parietal old/new effects. Indeed, while ERP old/new recognition effects were found in both groups when the picture of the face was physically identical to the one presented for study, the ERP correlates of recognition disappeared among patients when the background behind the face was different. This difficulty in disregarding a background change suggests that recognition among patients with schizophrenia is based on a global perceptual matching strategy rather than on the extraction of configural information from the face. The correlations observed between FN400 amplitude, the rejection of faces with a different background, and the reality-distortion scores support the idea that the recognition deficit found in schizophrenia results from early anomalies that are carried over onto the parietal ERP old/new effect. Face-extrinsic perceptual variations provide an opportune situation for gaining insight into the social difficulties that patients encounter throughout their lives.

  7. Calculation and experimental test of the cooling factor of tungsten

    Science.gov (United States)

    Pütterich, T.; Neu, R.; Dux, R.; Whiteford, A. D.; O'Mullane, M. G.; Summers, H. P.; ASDEX Upgrade Team

    2010-02-01

    The cooling factor of W is evaluated using state of the art data for line radiation and an ionization balance which has been benchmarked with experiment. For the calculation of line radiation, level-resolved calculations were performed with the Cowan code to obtain the electronic structure and excitation cross sections (plane-wave Born approximation). The data were processed by a collisional radiative model to obtain electron density dependent emissions. These data were then combined with the radiative power derived from recombination rates and bremsstrahlung to obtain the total cooling factor. The effect of uncertainties in the recombination rates on the cooling factor was studied and was identified to be of secondary importance. The new cooling factor is benchmarked, by comparisons of the line radiation with spectral measurements as well as with a direct measurement of the cooling factor. Additionally, a less detailed calculation using a configuration averaged model was performed. It was used to benchmark the level-resolved calculations and to improve the prediction on radiation power from line radiation for ionization stages which are computationally challenging. The obtained values for the cooling factor validate older predictions from the literature. Its ingredients and the absolute value are consistent with the existing experimental results regarding the value itself, the spectral distribution of emissions and the ionization equilibrium. A table of the cooling factor versus electron temperature is provided. Finally, the cooling factor is used to investigate the operational window of a fusion reactor with W as intrinsic impurity. The minimum value of nTτE, for which a thermonuclear burn is possible, is increased by 20% for a W concentration of 3.0 × 10-5 compared with a plasma without any impurities, except for the He ash which is considered in both cases.

  8. Testing the accuracy of radiative cooling approximations in SPH simulations

    CERN Document Server

    Wilkins, Daniel R

    2011-01-01

    Hydrodynamical simulations of star formation have stimulated a need to develop fast and robust algorithms for evaluating radiative cooling. Here we undertake a critical evaluation of what is currently a popular method for prescribing cooling in SPH simulations, i.e. the polytropic cooling due originally to Stamatellos et al. This method uses the local density and potential to estimate the column density and optical depth to each particle and then uses these quantities to evaluate an approximate expression for the net radiative cooling. We evaluate the algorithm by considering both spherical and disc-like systems with analytic density and temperature structures. In spherical systems, the total cooling rate computed by the method is within around 20 for the astrophysically relevant case of opacity dominated by ice grains and is correct to within a factor of order unity for a range of opacity laws. In disc geometry, however, the method systematically under-estimates the cooling by a large factor at all heights i...

  9. Beam Test of a Dielectric Loaded High Pressure RF Cavity for Use in Muon Cooling Channels

    Energy Technology Data Exchange (ETDEWEB)

    Freemire, Ben [IIT, Chicago; Bowring, Daniel [Fermilab; Kochemirovskiy, Alexey [Chicago U.; Moretti, Alfred [Fermilab; Peterson, David [Fermilab; Tollestrup, Alvin [Fermilab; Torun, Yagmur [IIT, Chicago; Yonehara, Katsuya [Fermilab

    2016-06-01

    Bright muon sources require six dimensional cooling to achieve acceptable luminosities. Ionization cooling is the only known method able to do so within the muon lifetime. One proposed cooling channel, the Helical Cooling Channel, utilizes gas filled radio frequency cavities to both mitigate RF breakdown in the presence of strong, external magnetic fields, and provide the cooling medium. Engineering constraints on the diameter of the magnets within which these cavities operate dictate the radius of the cavities be decreased at their nominal operating frequency. To accomplish this, one may load the cavities with a larger dielectric material. A 99.5% alumina ring was inserted in a high pressure RF test cell and subjected to an intense proton beam at the MuCool Test Area at Fermilab. The results of the performance of this dielectric loaded high pressure RF cavity will be presented.

  10. Thermal-hydraulic tests of a recirculation cooling installation for the Rostov nuclear power station

    Science.gov (United States)

    Balunov, B. F.; Balashov, V. A.; Il'in, V. A.; Krayushnikov, V. V.; Lychakov, V. D.; Meshalkin, V. V.; Ustinov, A. N.; Shcheglov, A. A.

    2013-09-01

    Results obtained from thermal-hydraulic tests of the recirculation cooling installation used as part of the air cooling system under the containments of the Rostov nuclear power station Units 3 and 4 are presented. The operating modes of the installation during normal operation (air cooling on the surface of finned tubes), under the conditions of anticipated operational occurrences (air cooling and steam condensation from a steam-air mixture), and during an accident (condensation of pure steam) are considered. Agreement is obtained between the results of tests and calculations carried out according to the recommendations given in the relevant regulatory documents. A procedure of carrying out thermal calculation for the case of steam condensation from a steam-air mixture on the surface of fins is proposed. The possibility of efficient use of the recirculation cooling installation in the system for reducing emergency pressure under the containment of a nuclear power station is demonstrated.

  11. Testing Lorentz Invariance with Laser-Cooled Cesium Atomic Frequency Standards

    Science.gov (United States)

    Klipstein, William M.

    2004-01-01

    This slide presentation reviews the Lorentz invariance testing during the proposed PARCS experiment. It includes information on the primary atomic reference clock in space (PARCS), cesium, laser cooling, and the vision for the future.

  12. Performance test of the cryogenic cooling system for the superconducting fault current limiter

    Science.gov (United States)

    Hong, Yong-Ju; In, Sehwan; Yeom, Han-Kil; Kim, Heesun; Kim, Hye-Rim

    2015-12-01

    A Superconducting Fault Current Limiter is an electric power device which limits the fault current immediately in a power grid. The SFCL must be cooled to below the critical temperature of high temperature superconductor modules. In general, they are submerged in sub-cooled liquid nitrogen for their stable thermal characteristics. To cool and maintain the target temperature and pressure of the sub-cooled liquid nitrogen, the cryogenic cooling system should be designed well with a cryocooler and coolant circulation devices. The pressure of the cryostat for the SFCL should be pressurized to suppress the generation of nitrogen bubbles in quench mode of the SFCL. In this study, we tested the performance of the cooling system for the prototype 154 kV SFCL, which consist of a Stirling cryocooler, a subcooling cryostat, a pressure builder and a main cryostat for the SFCL module, to verify the design of the cooling system and the electric performance of the SFCL. The normal operation condition of the main cryostat is 71 K and 500 kPa. This paper presents tests results of the overall cooling system.

  13. Electrical and Thermal View Points for Designing Conduction-Cooled Specimen Holder for Short Sample Testing

    Science.gov (United States)

    Järvelä, J.; Stenvall, A.; Mikkonen, R.

    Theelectrical and stabilitypropertiesof superconductivestrandsareoftencharacterizedby short sample testing.These tests are often done in a measurement system where the sample is cooled by liquid cryogen or cold gas flow. In both approaches, the sample temperature during a measurement is stabilized by the abundance of available cooling power. This also helps to protect the sample during a thermal runaway i.e. quench. However, in some characterizations, e.g. minimum quench energy testing, the cooling conditions can have a significant effect on the results. Therefore a more adiabatic solution is prefer able as iten able seasier comparison of the results from different measurement stations. One solution to achieving the desired adiabacy is to use conduction-cooling and vacuum insulation. As there is no cooling fluidtorelyon, as cheme for sample protection has to be implemented. Inaconduction-cooled setup, one way to protect the sampleis to use an active protection system in conjunction with aproperly designed sample holder. In this publication, we present an electrical and thermal analysis of a conduction-cooled sample holder suitable for both critical current and minimum quench energy measurements. A coupled electro-thermal finite element method model was constructed to study the sample holder performance during measurement. For our application, the performance is defined by the ohmic losses in the holder component sand by the recovery time from as amplequench.

  14. High Powered Tests of Dielectric Loaded High Pressure RF Cavities for Use in Muon Cooling Channels

    Energy Technology Data Exchange (ETDEWEB)

    Freemire, Ben [IIT, Chicago; Bowring, Daniel [Fermilab; Kochemirovskiy, Alexey [Chicago U.; Moretti, Alfred [Fermilab; Peterson, David [Fermilab; Tollestrup, Alvin [Fermilab; Torun, Yagmur [IIT, Chicago; Yonehara, Katsuya [Fermilab

    2016-06-01

    Bright muon sources require six dimensional cooling to achieve acceptable luminosities. Ionization cooling is the only known method able to do so within the muon lifetime. One proposed cooling channel, the Helical Cooling Channel, utilizes gas filled radio frequency cavities to both mitigate RF breakdown in the presence of strong, external magnetic fields, and provide the cooling medium. Engineering constraints on the diameter of the magnets within which these cavities operate dictate the radius of the cavities be decreased at their nominal operating frequency. To accomplish this, one may load the cavities with a larger dielectric material. Alumina of purities ranging from 96 to 99.8% was tested in a high pressure RF test cell at the MuCool Test Area at Fermilab. The results of breakdown studies with pure nitrogen gas, and oxygen-doped nitrogen gas indicate the peak surface electric field on the alumina ranges between 10 and 15 MV/m. How these results affect the design of a prototype cooling channel cavity will be discussed.

  15. Critical Current Test of Liquid Hydrogen Cooled HTC Superconductors under External Magnetic Field

    Science.gov (United States)

    Shirai, Yasuyuki; Shiotsu, Masahiro; Tatsumoto, Hideki; Kobayashi, Hiroaki; Naruo, Yoshihiro; Nonaka, Satoshi; Inatani, Yoshifumi

    High-Tc (HTC) superconductors including MgB2 will show excellent properties under temperature of Liquid Hydrogen (LH2:20K), which has large latent heat and low viscosity coefficient. In order to design and fabricate the LH2 cooled superconducting energy devices, we must clear the cooling property of LH2 for superconductors, the cooling system and safety design of LH2 cooled superconducting devices and electro-magnetic property evaluation of superconductors (BSCCO, REBCO and MgB2) and their magnets cooled by LH2. As the first step of the study, an experimental setup which can be used for investigating heat transfer characteristics of LH2 in a pool and also in forced flow (circulation loop with a pump), and also for evaluation of electro-magnetic properties of LH2 cooled superconductors under external magnetic field (up to 7 T). In this paper, we will show a short sketch of the experimental set-up, practical experiences in safety operation of liquid hydrogen cooling system and example test results of critical current evaluation of HTC superconductors cooled by LH2.

  16. a Cabinet Level Thermal Test Vehicle to Evaluate Hybrid Double-Sided Cooling Schemes

    Science.gov (United States)

    Nie, Qihong; Joshi, Yogendra

    Packaging of power semiconductor devices presents some of the greatest thermal design challenges due to the resulting high heat fluxes. Advanced cooling techniques are desired to help meet these demands for current and future devices. A hybrid double-sided approach combining micro-channel liquid cooling, thermoelectric cooling, and forced air convection is investigated via a test vehicle for the thermal management of electronic cabinets. A reduction of 74% in the chip junction temperature rise was achieved by using double-sided cooling, compared to single-sided air convection. Further reduction can be achieved by utilizing thermoelectric cooling (TEC). Additional reductions of 22.4% and 6.5% were achieved by utilizing TEC in single-sided air cooling and double-sided cooling, respectively. The effect of water flow rates through the air-to-liquid heat exchanger and the microchannel heat sink on the chip junction temperature rise was insignificant, compared to the effect of TEC, and cooling configuration.

  17. Test Report on ISR Double-Loop, Spray-Cooled Inverter

    Energy Technology Data Exchange (ETDEWEB)

    Hsu, John S [ORNL; Coomer, Chester [ORNL; Campbell, Steven L [ORNL; Wiles, Randy H [ORNL; Lowe, Kirk T [ORNL; McFee, Marshall T [ORNL

    2007-02-01

    The Isothermal Systems Research, Inc. (ISR) double-loop, two-phase spray cooling system was designed to use 85 C transmission oil to cool a heat exchanger via a second cooling loop. The heat exchanger condenses the working fluid vapor back to liquid inside a sealed enclosure to allow for continuous spray cooling of electronics. In the ORNL tests, 85 C water/ethylene/glycol (WEG), which has better thermal properties than transmission oil, was substituted for the transmission oil. Because the ISR spray-cooling system requires a second cooling loop, the final inverter might be inherently larger than inverters that do not require a second-loop cooling system. The ISR test setup did not include a dc bus capacitor. Because the insulated gate bipolar transistor (IGBT) conduction test indicated that the ISR test setup could not be properly loaded thermally, no switching tests were conducted. Therefore it was not necessary to attach external capacitors outside the test setup. During load situations not exceeding 400A, the WEG inlet temperature was higher than the WEG outlet temperature. This meant that the 85 C WEG heat exchanger was not cooling the inverter and became a thermal load to the inverter. Only when the load was higher than 400A with a higher coolant temperature and the release valve actuated did the WEG heat exchanger start to cool the 2-phase coolant. The inverter relied strongly on the cooling of the huge aluminum enclosure located inside the ventilation chamber. In a hybrid vehicle, the inverter is situated under the hood, where the dependency on cooling provided by the enclosure may become a problem. The IGBT power dissipation with both sides being spray cooled was around 34 W/cm{sup 2} at 403A, with 995W total IGBT loss at 113.5 C projected junction temperature before the release valve was actuated. The current loading could rise higher than 403 A before reaching the 125 C junction temperature limit if the pressure buildup inside the enclosure could be

  18. 78 FR 63516 - Initial Test Program of Emergency Core Cooling Systems for New Boiling-Water Reactors

    Science.gov (United States)

    2013-10-24

    ... COMMISSION Initial Test Program of Emergency Core Cooling Systems for New Boiling-Water Reactors AGENCY... Cooling Systems for New Boiling-Water Reactors.'' This RG describes testing methods the NRC staff considers acceptable for demonstrating the operability of emergency core cooling systems (ECCSs) for boiling...

  19. Thermal analysis of lithium cooled natural circulation loop module for fuel rod testing in the Fast Flux Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    Eyler, L.L.; Kim, D.; Stover, R.L.; Beaver, T.R.

    1987-01-01

    Maximum heat removal capability of a lithium cooled natural circulation fuel rod test module design is determined. Loop geometry is optimized within limitations of design specifications for nominal operation temperatures, materials, and test module environment. Results provide test module operation limits and range of potential uncertainties. 3 refs., 12 figs.

  20. Cryogenic mechanical property testing system directly cooled by G-M cryocooler

    Science.gov (United States)

    Huang, R. J.; Liu, Q.; Li, L. F.; Gong, L. H.; Liu, H. M.; Xu, D.

    2014-01-01

    Cryogenic mechanical properties are generally considered to be some of the most important parameters in cryogenic engineering. Therefore, it is very important to test and investigate mechanical properties at low temperatures. Most systems for cryogenic mechanical property testing are cooled using liquid nitrogen (300 K-77 K) or liquid helium (77 K-4.2 K). As we know, liquid helium is relatively rare and thus expensive. In this study, to attain accurate and stable intermediate temperatures and reduce testing cost, a cryogenic mechanical property testing system cooled by a G-M cryocooler was studied and developed. In this system, the sample can be cooled down to 10.5 K after about 10 hours of running. The tension, bending and compression testing (load range up to 50 kN) can be carried out.

  1. Thermal cycling tests of actively cooled beryllium copper joints

    Energy Technology Data Exchange (ETDEWEB)

    Roedig, M.; Duwe, R.; Linke, J.; Schuster, A.; Wiechers, B. [Forschungszentrum Juelich GmbH (Germany)

    1998-01-01

    Screening tests (steady state heating) and thermal fatigue tests with several kinds of beryllium-copper joints have been performed in an electron beam facility. Joining techniques under investigation were brazing with silver containing and silver-free braze materials, hot isostatic pressing (HIP) and diffusion bonding (hot pressing). Best thermal fatigue performance was found for the brazed samples. (author)

  2. Experimental characterization of the ITER TF structure cooling in HELIOS test facility

    Science.gov (United States)

    Hoa, C.; Rousset, B.; Lacroix, B.; Nicollet, S.; Vallcorba, R.; Bessette, D.; Vostner, A.; Gauthier, F.

    2015-12-01

    During ITER plasma operation, large thermal loads are generated in the stainless steel Toroidal Field (TF) coil casing. To minimize the impact on the temperature of the TF Cable in Conduit Conductor (CICC), these heat loads are intercepted by case cooling channels which are implemented at the interface to the winding pack. One of the design options for the case cooling channels consists of a stainless steel pipe inserted in a rectangular groove which is machined in the casing and filled by a charged resin of high thermal conductivity. A higher number of cooling pipes is arranged at the plasma facing wall of the case, thus providing a better shielding to the TF conductor at high field. To assess the efficiency of the cooling pipes and their thermal coupling with the charged resin, experimental characterizations have been performed. First of all, the thermal resistance vs temperature of some of the individual components of a TF coil has been measured on representative samples in a cryogenic bench. Further characterizations have been performed on an integrated mock-up of the TF cooling scheme at cryogenic temperature in HELIOS test facility at CEA Grenoble. The mock-up consists of a piece of TF casing that can be heated uniformly on its surface, one cooling channel implemented in the groove which is filled with the charged resin, the filler, the ground insulation, the radial plate and one insulated CICC. The cooling pipe and the CICC are cooled by supercritical helium at 4.4 K and 5 bar; the instrumentation consists of temperature, pressure and mass flow sensors. Both stationary and transient operating modes have been investigated to assess the thermal efficiency of the case cooling design. The experimental tests are presented and the first results are discussed and analyzed in this document.

  3. Thermo-hydraulic analysis of the cool-down of the EDIPO test facility

    Science.gov (United States)

    Lewandowska, Monika; Bagnasco, Maurizio

    2011-09-01

    The first cool-down of the EDIPO (European DIPOle) test facility is foreseen to take place in 2011 by means of the existing 1.2 kW cryoplant at EPFL-CRPP Villigen. In this work, the thermo-hydraulic analysis of the EDIPO cool-down is performed in order both to assess the its duration and to optimize the procedure. The cool-down is driven by the helium flowing in both the outer cooling channel and in the windings connected hydraulically in parallel. We take into account limitations due to the pressure drop in the cooling circuit and the refrigerator capacity as well as heat conduction in the iron yoke. Two schemes of the hydraulic cooling circuit in the EDIPO windings are studied (coils connected in series and coils connected in parallel). The analysis is performed by means of an analytical model complemented by and numerical model. The results indicate that the cool-down to 5 K can be achieved in about 12 days.

  4. Testing the Large-scale Environments of Cool-core and Non-cool-core Clusters with Clustering Bias

    Science.gov (United States)

    Medezinski, Elinor; Battaglia, Nicholas; Coupon, Jean; Cen, Renyue; Gaspari, Massimo; Strauss, Michael A.; Spergel, David N.

    2017-02-01

    There are well-observed differences between cool-core (CC) and non-cool-core (NCC) clusters, but the origin of this distinction is still largely unknown. Competing theories can be divided into internal (inside-out), in which internal physical processes transform or maintain the NCC phase, and external (outside-in), in which the cluster type is determined by its initial conditions, which in turn leads to different formation histories (i.e., assembly bias). We propose a new method that uses the relative assembly bias of CC to NCC clusters, as determined via the two-point cluster-galaxy cross-correlation function (CCF), to test whether formation history plays a role in determining their nature. We apply our method to 48 ACCEPT clusters, which have well resolved central entropies, and cross-correlate with the SDSS-III/BOSS LOWZ galaxy catalog. We find that the relative bias of NCC over CC clusters is b = 1.42 ± 0.35 (1.6σ different from unity). Our measurement is limited by the small number of clusters with core entropy information within the BOSS footprint, 14 CC and 34 NCC clusters. Future compilations of X-ray cluster samples, combined with deep all-sky redshift surveys, will be able to better constrain the relative assembly bias of CC and NCC clusters and determine the origin of the bimodality.

  5. Making System Dynamics Cool IV: Teaching & Testing with Cases & Quizzes

    NARCIS (Netherlands)

    Pruyt, E.

    2012-01-01

    This follow-up paper presents cases and multiple choice questions for teaching and testing System Dynamics modeling. These cases and multiple choice questions were developed and used between January 2012 and April 2012 a large System Dynamics course (250+ 2nd year BSc and 40+ MSc students per year)

  6. Making System Dynamics Cool III: New Hot Teaching & Testing Cases

    NARCIS (Netherlands)

    Pruyt, E.

    2011-01-01

    This follow-up paper presents seven actual cases for testing and teaching System Dynamics developed and used between January 2010 and January 2011 for one of the largest System Dynamics courses (250+ students per year) at Delft University of Technology in the Netherlands. The cases presented in this

  7. Making System Dynamics Cool IV: Teaching & Testing with Cases & Quizzes

    NARCIS (Netherlands)

    Pruyt, E.

    2012-01-01

    This follow-up paper presents cases and multiple choice questions for teaching and testing System Dynamics modeling. These cases and multiple choice questions were developed and used between January 2012 and April 2012 a large System Dynamics course (250+ 2nd year BSc and 40+ MSc students per year)

  8. Vibration syndrome diagnosis using a cooling test verified by computerized photoplethysmography.

    Science.gov (United States)

    Dyszkiewicz, Andrzej; Tendera, Michał

    2006-04-01

    This study addresses the problem of vibration syndrome diagnosis by means of a cooling test verified by photoplethysmography. Measurement was taken on a small area on the fingertip plexus in which many arterio-venous anastomoses are present. In the opinion of many authors, flow disorders in this area are more typical for developing vibration syndrome than changes in the micro vessels. The study group comprised 128 subjects (58 women aged 40.9 +/- 5.4 years and 70 men aged 38.7 +/- 8.8 years) exposed to vibration. The control group consisted of 41 people (20 women aged 39.6 +/- 7.3 years and 21 men aged 39.3 +/- 6.4 years) who were not exposed to vibration. The patients were examined by a questionnaire and then a vibration perception threshold test and a cooling test were performed. The cooling test was verified both visually and using the computer method. Measurement data (S1, S2 and A) for each patient were obtained from averaging three pulse graphs. We departed from an average of 60 graphs (and more), the standard established in the literature, because of the cooling test specification, which causes huge thermodynamic parameter changeability in the plexus mass of the small finger under pulse waves coming one after another. A longer measurement time will reflect the thermal drift of the tested area in a direction to compensate for the reduced temperature. In the control group, all subjects showed an increase in planimetric indicators during the cooling test verified by computerized photoplethysmography. In the study group visual verification of the cooling test was positive in eight cases (6.2%) and the vibration perception threshold test was positive in seven cases (5.5%), but in computerized photoplethysmography the planimetric indicators decreased after cooling in 87 (67.4%) cases. Computer photoplethysmography is highly specific and shows greater sensitivity in detecting preclinical forms of vascular-type vibration syndrome when compared with palesthesiometry

  9. Optimal control and performance test of solar-assisted cooling system

    KAUST Repository

    Huang, B.J.

    2010-10-01

    The solar-assisted cooling system (SACH) was developed in the present study. The ejector cooling system (ECS) is driven by solar heat and connected in parallel with an inverter-type air conditioner (A/C). The cooling load can be supplied by the ECS when solar energy is available and the input power of the A/C can be reduced. In variable weather, the ECS will probably operate at off-design condition of ejector and the cooling capability of the ECS can be lost completely. In order to make the ejector operate at critical or non-critical double-choking condition to obtain a better performance, an electronic expansion valve was installed in the suction line of the ejector to regulate the opening of the expansion valve to control the evaporator temperature. This will make the SACH always produce cooling effect even at lower solar radiation periods while the ejector performs at off-design conditions. The energy saving of A/C is experimentally shown 50-70% due to the cooling performance of ECS. The long-term performance test results show that the daily energy saving is around 30-70% as compared to the energy consumption of A/C alone (without solar-driven ECS). The total energy saving of A/C is 52% over the entire test period. © 2010 Elsevier Ltd. All rights reserved.

  10. Modeling of gap cooling phenomena in LAVA-4 test using MELCOR

    Energy Technology Data Exchange (ETDEWEB)

    Park, J.H.; Park, S.Y.; Kim, S.D.; Song, Y.M.; Kim, D.H. [Korea Atomic Energy Research Inst., Daeduk (Korea)

    2000-07-01

    During the severe accident, the coolability of hot debris in the hemispherical lower vessel head has been an important issue concerning the plant safety. KAERI has launched the 'SONATA' experimental program and series of LAVA test have been performed to examine the existence of initial gap and its effect on the cooling of hot debris. A gap-cooling phenomenon was modeled and implemented into the lower plenum model in MELCOR. The calculation with considering the gap cooling phenomena shows a good prediction of the rapid cool clown of the vessel wall and the debris. But this model needs more refinement and evaluation against the experimental results before application to the plant. (author)

  11. A cryogenic tensile testing apparatus for micro-samples cooled by miniature pulse tube cryocooler

    Science.gov (United States)

    Chen, L. B.; Liu, S. X.; Gu, K. X.; Zhou, Y.; Wang, J. J.

    2015-12-01

    This paper introduces a cryogenic tensile testing apparatus for micro-samples cooled by a miniature pulse tube cryocooler. At present, tensile tests are widely applied to measure the mechanical properties of materials; most of the cryogenic tensile testing apparatus are designed for samples with standard sizes, while for non-standard size samples, especially for microsamples, the tensile testing cannot be conducted. The general approach to cool down the specimens for tensile testing is by using of liquid nitrogen or liquid helium, which is not convenient: it is difficult to keep the temperature of the specimens at an arbitrary set point precisely, besides, in some occasions, liquid nitrogen, especially liquid helium, is not easily available. To overcome these limitations, a cryogenic tensile testing apparatus cooled by a high frequency pulse tube cryocooler has been designed, built and tested. The operating temperatures of the developed tensile testing apparatus cover from 20 K to room temperature with a controlling precision of ±10 mK. The apparatus configurations, the methods of operation and some cooling performance will be described in this paper.

  12. A Conduction-Cooled Superconducting Magnet System-Design, Fabrication and Thermal Tests

    DEFF Research Database (Denmark)

    Song, Xiaowei (Andy); Holbøll, Joachim; Wang, Qiuliang

    2015-01-01

    A conduction-cooled superconducting magnet system with an operating current of 105.5 A was designed, fabricated and tested for material processing applications. The magnet consists of two coaxial NbTi solenoid coils with an identical vertical height of 300 mm and is installed in a high-vacuumed c......A conduction-cooled superconducting magnet system with an operating current of 105.5 A was designed, fabricated and tested for material processing applications. The magnet consists of two coaxial NbTi solenoid coils with an identical vertical height of 300 mm and is installed in a high...

  13. Design, Fabrication, and Testing of an Auxiliary Cooling System for Jet Engines

    Science.gov (United States)

    Leamy, Kevin; Griffiths, Jim; Andersen, Paul; Joco, Fidel; Laski, Mark; Balser, Jeffrey (Technical Monitor)

    2001-01-01

    This report summarizes the technical effort of the Active Cooling for Enhanced Performance (ACEP) program sponsored by NASA. It covers the design, fabrication, and integrated systems testing of a jet engine auxiliary cooling system, or turbocooler, that significantly extends the use of conventional jet fuel as a heat sink. The turbocooler is designed to provide subcooled cooling air to the engine exhaust nozzle system or engine hot section. The turbocooler consists of three primary components: (1) a high-temperature air cycle machine driven by engine compressor discharge air, (2) a fuel/ air heat exchanger that transfers energy from the hot air to the fuel and uses a coating to mitigate fuel deposits, and (3) a high-temperature fuel injection system. The details of the turbocooler component designs and results of the integrated systems testing are documented. Industry Version-Data and information deemed subject to Limited Rights restrictions are omitted from this document.

  14. Design, fabrication and test of Load Bearing multilayer insulation to support a broad area cooled shield

    Science.gov (United States)

    Dye, S. A.; Johnson, W. L.; Plachta, D. W.; Mills, G. L.; Buchanan, L.; Kopelove, A. B.

    2014-11-01

    Improvements in cryogenic propellant storage are needed to achieve reduced or Zero Boil Off of cryopropellants, critical for long duration missions. Techniques for reducing heat leak into cryotanks include using passive multi-layer insulation (MLI) and vapor cooled or actively cooled thermal shields. Large scale shields cannot be supported by tank structural supports without heat leak through the supports. Traditional MLI also cannot support shield structural loads, and separate shield support mechanisms add significant heat leak. Quest Thermal Group and Ball Aerospace, with NASA SBIR support, have developed a novel Load Bearing multi-layer insulation (LBMLI) capable of self-supporting thermal shields and providing high thermal performance. We report on the development of LBMLI, including design, modeling and analysis, structural testing via vibe and acoustic loading, calorimeter thermal testing, and Reduced Boil-Off (RBO) testing on NASA large scale cryotanks. LBMLI uses the strength of discrete polymer spacers to control interlayer spacing and support the external load of an actively cooled shield and external MLI. Structural testing at NASA Marshall was performed to beyond maximum launch profiles without failure. LBMLI coupons were thermally tested on calorimeters, with superior performance to traditional MLI on a per layer basis. Thermal and structural tests were performed with LBMLI supporting an actively cooled shield, and comparisons are made to the performance of traditional MLI and thermal shield supports. LBMLI provided a 51% reduction in heat leak per layer over a previously tested traditional MLI with tank standoffs, a 38% reduction in mass, and was advanced to TRL5. Active thermal control using LBMLI and a broad area cooled shield offers significant advantages in total system heat flux, mass and structural robustness for future Reduced Boil-Off and Zero Boil-Off cryogenic missions with durations over a few weeks.

  15. Preliminary Tests of Nose- and Side- Entrance Blower Cooling Systems for Radial Engines, Special Report

    Science.gov (United States)

    Biermann, David; Valentine, E. Floyd

    1939-01-01

    Two cowling systems intended to reduce the drag and improve the low-speed cooling characteristics of conventional radial engine cowlings were tested in model form to determine the practicability of the methods. One cowling included a blower mounted on the rear face of a large propeller spinner which drew cooling air in through side entrance ducts located behind the equivalent engine orifice plate. The air was passed through the equivalent engine orifice plate from rear to front and out through a slot between the spinner and the engine plate. The blower produced substantially all the power necessary to circulate the cooling air in some cases, so the quantity of air flowing was independent of the air speed, Two types of blowers were used, a centrifugal type and one using airfoil blades which forced the air outward from the center of rotation. The other cowling was similar to the conventional N.A.C.A. cowling except for the addition of a large propeller spinner nose. The spinner was provided with a hole in the nose to admit cooling air and blower blades to increase the pressure for cooling at low speeds. The tests show that with both cowling types the basic drag of the nacelle was reduced substantially below that for the N.A.C.A. cowling by virtue of the better nose shape made possible by the spinner . The drag due to the side-entrance ducts was nearly zero when the openings were closed or when the blower was drawing in a certain quantity of air in proportion to the air speed. The drag increased, however, when air mas allowed to spill from the openings. The nose-entrance blower showed considerable promise as a cooling means although the blower tested was relatively inefficient, owing to the fact that the blower compartments evidently were expanded too rapidly under the conditions imposed. by the design.

  16. Design, construction, and testing of a residential solar heating and cooling system

    Energy Technology Data Exchange (ETDEWEB)

    Ward, D.S.; Loef, G.O.G.

    1976-06-01

    The NSF/CSU Solar House I solar heating and cooling system became operational on 1 July 1974. During the first months of operation the emphasis was placed on adjustment, ''tuning,'' and fault correction in the solar collection and the solar/fuel/cooling subsystems. Following this initial check out period, analysis and testing of the system utilizing a full year of data were accomplished. This report discusses the results of this analysis of the full year of operation. (WDM)

  17. High Temperature Gas-Cooled Test Reactor Point Design: Summary Report

    Energy Technology Data Exchange (ETDEWEB)

    Sterbentz, James William [Idaho National Lab. (INL), Idaho Falls, ID (United States); Bayless, Paul David [Idaho National Lab. (INL), Idaho Falls, ID (United States); Nelson, Lee Orville [Idaho National Lab. (INL), Idaho Falls, ID (United States); Gougar, Hans David [Idaho National Lab. (INL), Idaho Falls, ID (United States); Kinsey, J. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Strydom, Gerhard [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-03-01

    A point design has been developed for a 200-MW high-temperature gas-cooled test reactor. The point design concept uses standard prismatic blocks and 15.5% enriched uranium oxycarbide fuel. Reactor physics and thermal-hydraulics simulations have been performed to characterize the capabilities of the design. In addition to the technical data, overviews are provided on the technology readiness level, licensing approach, and costs of the test reactor point design.

  18. High Temperature Gas-Cooled Test Reactor Point Design: Summary Report

    Energy Technology Data Exchange (ETDEWEB)

    Sterbentz, James William [Idaho National Lab. (INL), Idaho Falls, ID (United States); Bayless, Paul David [Idaho National Lab. (INL), Idaho Falls, ID (United States); Nelson, Lee Orville [Idaho National Lab. (INL), Idaho Falls, ID (United States); Gougar, Hans David [Idaho National Lab. (INL), Idaho Falls, ID (United States); Strydom, Gerhard [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-01-01

    A point design has been developed for a 200-MW high-temperature gas-cooled test reactor. The point design concept uses standard prismatic blocks and 15.5% enriched uranium oxycarbide fuel. Reactor physics and thermal-hydraulics simulations have been performed to characterize the capabilities of the design. In addition to the technical data, overviews are provided on the technology readiness level, licensing approach, and costs of the test reactor point design.

  19. Design, Testing and Modeling of the Direct Reactor Auxiliary Cooling System for AHTRs

    Energy Technology Data Exchange (ETDEWEB)

    Lv, Quiping [The Ohio State Univ., Columbus, OH (United States); Sun, Xiaodong [The Ohio State Univ., Columbus, OH (United States); Chtistensen, Richard [The Ohio State Univ., Columbus, OH (United States); Blue, Thomas [The Ohio State Univ., Columbus, OH (United States); Yoder, Graydon [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Wilson, Dane [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-05-08

    The principal objective of this research is to test and model the heat transfer performance and reliability of the Direct Reactor Auxiliary Cooling System (DRACS) for AHTRs. In addition, component testing of fluidic diodes is to be performed to examine the performance and viability of several existing fluidic diode designs. An extensive database related to the thermal performance of the heat exchangers involved will be obtained, which will be used to benchmark a computer code for the DRACS design and to evaluate and improve, if needed, existing heat transfer models of interest. The database will also be valuable for assessing the viability of the DRACS concept and benchmarking any related computer codes in the future. The experience of making a liquid fluoride salt test facility available, with lessons learned, will greatly benefit the development of the Fluoride Salt-cooled High-temperature Reactor (FHR) and eventually the AHTR programs.

  20. Test Method for Thermal Characterization of Li-Ion Cells and Verification of Cooling Concepts

    Directory of Open Access Journals (Sweden)

    Rouven Christen

    2017-01-01

    Full Text Available Temperature gradients, thermal cycling and temperatures outside the optimal operation range can have a significant influence on the reliability and lifetime of Li-ion battery cells. Therefore, it is essential for the developer of large-scale battery systems to know the thermal characteristics, such as heat source location, heat capacity and thermal conductivity, of a single cell in order to design appropriate cooling measures. This paper describes an advanced test facility, which allows not only an estimation of the thermal properties of a battery cell, but also the verification of proposed cooling strategies in operation. To do this, an active measuring unit consisting of a temperature and heat flux density sensor and a Peltier element was developed. These temperature/heat flux sensing (THFS units are uniformly arranged around a battery cell with a spatial resolution of 25 mm. Consequently, the temperature or heat flux density can be controlled individually, thus forming regions with constant temperature (cooling or zero heat flux (insulation. This test setup covers the whole development loop from thermal characterization to the design and verification of the proposed cooling strategy.

  1. Plate coil thermal test bench for the Daniel K. Inouye Solar Telescope (DKIST) carousel cooling system

    Science.gov (United States)

    Phelps, LeEllen; Murga, Gaizka; Montijo, Guillermo; Hauth, David

    2014-08-01

    Analyses have shown that even a white-painted enclosure requires active exterior skin-cooling systems to mitigate dome seeing which is driven by thermal nonuniformities that change the refractive index of the air. For the Daniel K. Inouye Solar Telescope (DKIST) Enclosure, this active surface temperature control will take the form of a system of water cooled plate coils integrated into the enclosure cladding system. The main objective of this system is to maintain the surface temperature of the enclosure as close as possible to, but always below, local ambient temperature in order to mitigate this effect. The results of analyses using a multi-layer cladding temperature model were applied to predict the behavior of the plate coil cladding system and ultimately, with safety margins incorporated into the resulting design thermal loads, the detailed designs. Construction drawings and specifications have been produced. Based on these designs and prior to procurement of the system components, a test system was constructed in order to measure actual system behavior. The data collected during seasonal test runs at the DKIST construction site on Haleakalā are used to validate and/or refine the design models and construction documents as appropriate. The test fixture was also used to compare competing hardware, software, components, control strategies, and configurations. This paper outlines the design, construction, test protocols, and results obtained of the plate coil thermal test bench for the DKIST carousel cooling system.

  2. Physical design and cooling test of C-band standing wave accelerating tube

    Institute of Scientific and Technical Information of China (English)

    Bai Wei; Xu Zhou; Jin Xiao; Li Ming

    2006-01-01

    The physical design and cooling test of a C-band 2MeV standing wave (SW) accelerating tube are described in this paper. The designed accelerating structure consists of 3-cell buncher and 4-cell accelerating section with a total length of about 163mm , excited with 1MW magnetron. Dynamic simulation presents that about 150mA beam pulse current and 30% capture efficiency can be achieved. By means of nonlinear Gauss fit on electron transverse distribution, the diameter of beam spot FWHM (full width at half maximum of density distribution) is about 0.55mm. Cooling test results of the accelerating tube show that frequencies of cavities are tuned to 5527MHz and the field distribution of bunching section is about 3:9:10.

  3. High power testing of water-cooled waveguide for ITER-like ECH transmission lines

    Science.gov (United States)

    Anderson, J. P.; Doane, J. L.; Grunloh, H. J.; O'Neill, R. C.; Ikeda, R.; Oda, Y.; Takahashi, K.; Sakamoto, K.

    2017-05-01

    The results of high power testing of new water-cooled ECH waveguide components for ITER are presented. The components are a precision-coupled 4.2 m waveguide assembly, a short expansion joint, and water-cooled waveguide for gyrotron commissioning. The testing was conducted at the QST Naka Fusion Institute using gyrotron pulses of 450 kW at 170 GHz for 300 s. Analysis shows that the power absorbed per unit length for the various waveguide components are dependent on location in the transmission line with respect to high order mode generators, such as miter bends. Additionally, larger-than-expected reflections from the load led to high absorption levels in the transmission line.

  4. Cooling Performance Test of the SCT LV&HV Power Supply Rack

    CERN Document Server

    Böhm, J; Vacek, V

    2005-01-01

    The cooling performance test of the 52U rack, housing SCT LV&HV power supplies for 192 detector modules, being located in USA15 cavern, has been curried out. The rack was equipped with two air-water heat exchangers, air turbine, four vertical fan tray units under crates and horizontal fans in four Artesyn AC/DC power supply units. The resistive dummy loads for 192 power supply channels have been placed in four crates and housed in the adjacent rack.

  5. Facility Configuration Study of the High Temperature Gas-Cooled Reactor Component Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    S. L. Austad; L. E. Guillen; D. S. Ferguson; B. L. Blakely; D. M. Pace; D. Lopez; J. D. Zolynski; B. L. Cowley; V. J. Balls; E.A. Harvego, P.E.; C.W. McKnight, P.E.; R.S. Stewart; B.D. Christensen

    2008-04-01

    A test facility, referred to as the High Temperature Gas-Cooled Reactor Component Test Facility or CTF, will be sited at Idaho National Laboratory for the purposes of supporting development of high temperature gas thermal-hydraulic technologies (helium, helium-Nitrogen, CO2, etc.) as applied in heat transport and heat transfer applications in High Temperature Gas-Cooled Reactors. Such applications include, but are not limited to: primary coolant; secondary coolant; intermediate, secondary, and tertiary heat transfer; and demonstration of processes requiring high temperatures such as hydrogen production. The facility will initially support completion of the Next Generation Nuclear Plant. It will secondarily be open for use by the full range of suppliers, end-users, facilitators, government laboratories, and others in the domestic and international community supporting the development and application of High Temperature Gas-Cooled Reactor technology. This pre-conceptual facility configuration study, which forms the basis for a cost estimate to support CTF scoping and planning, accomplishes the following objectives: • Identifies pre-conceptual design requirements • Develops test loop equipment schematics and layout • Identifies space allocations for each of the facility functions, as required • Develops a pre-conceptual site layout including transportation, parking and support structures, and railway systems • Identifies pre-conceptual utility and support system needs • Establishes pre-conceptual electrical one-line drawings and schedule for development of power needs.

  6. Experimental test of the heating and cooling rate effect on blocking temperatures

    Science.gov (United States)

    Berndt, Thomas; Paterson, Greig A.; Cao, Changqian; Muxworthy, Adrian R.

    2017-07-01

    The cooling rates at which rocks acquire thermoremanent magnetizations (TRMs), affect their unblocking temperatures in thermal demagnetization experiments; similarly the heating rates at which the thermal demagnetization experiments are done also affect the unblocking temperature. We have tested the effects of variable cooling and heating rates on the unblocking temperatures of two natural non-interacting, magnetically uniform (single-domain, SD) (titano)magnetite samples and a synthetic SD magnetoferritin sample. While previous studies have only considered unblocking temperatures for stepwise thermal demagnetization data (i.e. the room-temperature magnetization after incremental heating), in this work we derive an expression for continuous thermal demagnetization of both TRMs and viscous remanent magnetizations (VRMs) and relate the heating rate to an effective equivalent hold time of a stepwise thermal demagnetization experiment. Through our analysis we reach four main conclusions: First, the theoretical expressions for the heating/cooling rate effect do not accurately predict experimentally observed blocking temperatures. Empirically, the relation can be modified incorporating a factor that amplifies both the temperature and the heating rate dependence of the heating/cooling rate effect. Using these correction factors, Pullaiah nomograms can accurately predict blocking temperatures of both TRMs and VRMs for continuous heating/cooling. Second, demagnetization temperatures are approximately predicted by published 'Pullaiah nomograms', but blocking occurs gradually over temperature intervals of 5-40 K. Third, the theoretically predicted temperatures correspond to ∼54-82 per cent blocking, depending on the sample. Fourth, the blocking temperatures can be used to obtain estimates of the atomic attempt time τ0, which were found to be 3 × 10-10 s for large grained (titano)magnetite, 1 × 10-13 s for small grained (titano)magnetite below the Verwey transition and 9

  7. Experimental testing of cooling by low pressure adsorption in a zeolite

    Energy Technology Data Exchange (ETDEWEB)

    Redman, C.M.

    1985-01-01

    A small scale facility was designed, constructed, and utilized to test the use of zeolite adsorption of water vapor to augment chill storage in ice for conventional space cooling. The facility uses solar-derived energy, for the heat source and evaporatively chilled water for the heat sump. The product cooling uses sublimation of ice instead of melting. The ZCAT facility utilizes a heat pumping technique in which a water vapor adsorbent functions as the compressor and condenser. The design was based on use of 13X zeolite as the adsorber because of its high adsorbence at low pressures. However, it has been determined that other materials such as silica gel should give superior performance. While zeolite 13X holds more water in the pressure and temperature ranges of interest, silica gel cycles more water and has less residue water. Both points are very important in the design of an efficient and cost effective system.

  8. Global cooling after the eruption of Mount Pinatubo: a test of climate feedback by water vapor.

    Science.gov (United States)

    Soden, Brian J; Wetherald, Richard T; Stenchikov, Georgiy L; Robock, Alan

    2002-04-26

    The sensitivity of Earth's climate to an external radiative forcing depends critically on the response of water vapor. We use the global cooling and drying of the atmosphere that was observed after the eruption of Mount Pinatubo to test model predictions of the climate feedback from water vapor. Here, we first highlight the success of the model in reproducing the observed drying after the volcanic eruption. Then, by comparing model simulations with and without water vapor feedback, we demonstrate the importance of the atmospheric drying in amplifying the temperature change and show that, without the strong positive feedback from water vapor, the model is unable to reproduce the observed cooling. These results provide quantitative evidence of the reliability of water vapor feedback in current climate models, which is crucial to their use for global warming projections.

  9. Testing of heating and cooling process of ADI cast iron with use of ATND method

    Directory of Open Access Journals (Sweden)

    A. Białobrzeski

    2008-10-01

    Full Text Available ADI (Austempered Ductile Iron cast iron, owing to its unique combination of high tensile strength and abrasion resistance with very goodplasticity, founds implementation in many branches of industry as a substitute of alloy cast steel and carburized or heat treated steels. Inspite of its solid position among producers and recipients of castings, there are still undertaken studies aimed at perfection of its propertiesand recognition of mechanisms enabling obtaining such properties.The paper presents implementation of thermal-voltage-derivative (ATND method to registration of heating and cooling course of ADIcast iron with EN-GJS-1200-2 grade. ADI cast iron with EN-GJS-1200-2 grade underwent the study. Heat treatment of the cast iron wasperformed in Foundry Institute with use of LT ADI-350/1000 processing line. Results obtained from the testing illustrate in graphic formregistered heating and cooling curves of investigated cast irons obtained with use of the ATND method.

  10. Computation over Mismatched Channels

    CERN Document Server

    Karamchandani, Nikhil; Diggavi, Suhas

    2012-01-01

    We consider the problem of distributed computation of a target function over a multiple-access channel. If the target and channel functions are matched (i.e., compute the same function), significant performance gains can be obtained by jointly designing the computation and communication tasks. However, in most situations there is mismatch between these two functions. In this work, we analyze the impact of this mismatch on the performance gains achievable with joint computation and communication designs over separation-based designs. We show that for most pairs of target and channel functions there is no such gain, and separation of computation and communication is optimal.

  11. Pre-irradiation testing of actively cooled Be-Cu divertor modules

    Energy Technology Data Exchange (ETDEWEB)

    Linke, J.; Duwe, R.; Kuehnlein, W. [Forschungszentrum Juelich GmbH (Germany)] [and others

    1995-09-01

    A set of neutron irradiation tests is prepared on different plasma facing materials (PFM) candidates and miniaturized components for ITER. Beside beryllium the irradiation program which will be performed in the High Flux Reactor (HFR) in Petten, includes different carbon fiber composites (CFQ) and tungsten alloys. The target values for the neutron irradiation will be 0.5 dpa at temperatures of 350{degrees}C and 700{degrees}C, resp.. The post irradiation examination (PIE) will cover a wide range of mechanical tests; in addition the degradation of thermal conductivity will be investigated. To determine the high heat flux (HHF) performance of actively cooled divertor modules, electron beam tests which simulate the expected heat loads during the operation of ITER, are scheduled in the hot cell electron beam facility JUDITH. These tests on a selection of different actively cooled beryllium-copper and CFC-copper divertor modules are performed before and after neutron irradiation; the pre-irradiation testing is an essential part of the program to quantify the zero-fluence high heat flux performance and to detect defects in the modules, in particular in the brazed joints.

  12. Mysterious ionization in cooling flow filaments: a test with deep COS FUV spectroscopy

    Science.gov (United States)

    Tremblay, Grant

    2013-10-01

    The Cosmic Origins Spectrograph is capable of unraveling a two decade old mystery regarding the filamentary emission line nebulae found in the brightest cluster galaxies {BCGs} of cool core {CC} clusters. These kpc-scale filaments are characterized by elevated H-alpha luminosities and puzzling ionization states that cannot be accounted for by recombination or photionization alone, and are instead excited by an unknown ionization mechanism. The most hotly debated proposed solutions invoke thermal conduction, shocks, or cosmic-ray heating, but progress toward consensus awaits unambiguous spectral discriminants between these models that can only be found in the FUV. We propose deep {9 orbit}, off-nuclear observations of two strategically selected BCGs in well-studied cool core clusters with cross-spectrum archival datasets. We also propose a shorter {5 orbit} on-nuclear observation for one of our targets to assess possible AGN contributions to the spectra. These proposed observations represent critical tests that can unambiguously discriminate between the various candidate ionziation models. Constraining the mechanisms by which CC BCG filaments are excited remains one of the most important roadblocks to a better understanding of cooling from hot ambient medium to cold star forming clouds and filaments, a process important for both galaxy and black hole growth. It is therefore important that, before HST ends its mission and we lose FUV capability, we advance our understanding of this decades old mystery.

  13. The ITER neutral beam test facility: Designs of the general infrastructure, cryosystem and cooling plant

    Energy Technology Data Exchange (ETDEWEB)

    Cordier, J.J. [Association EURATOM-CEA, DSM, Departement Recherche Fusion Controlee, CEA/Cadarache, bat 506, F-13108 Saint Paul Lez Durance Cedex (France)]. E-mail: jean-jacques.cordier@cea.fr; Hemsworth, R. [Association EURATOM-CEA, DSM, Departement Recherche Fusion Controlee, CEA/Cadarache, bat 506, F-13108 Saint Paul Lez Durance Cedex (France); Chantant, M. [Association EURATOM-CEA, DSM, Departement Recherche Fusion Controlee, CEA/Cadarache, bat 506, F-13108 Saint Paul Lez Durance Cedex (France); Gravil, B. [Association EURATOM-CEA, DSM, Departement Recherche Fusion Controlee, CEA/Cadarache, bat 506, F-13108 Saint Paul Lez Durance Cedex (France); Henry, D. [Association EURATOM-CEA, DSM, Departement Recherche Fusion Controlee, CEA/Cadarache, bat 506, F-13108 Saint Paul Lez Durance Cedex (France); Sabathier, F. [Association EURATOM-CEA, DSM, Departement Recherche Fusion Controlee, CEA/Cadarache, bat 506, F-13108 Saint Paul Lez Durance Cedex (France); Doceul, L. [Association EURATOM-CEA, DSM, Departement Recherche Fusion Controlee, CEA/Cadarache, bat 506, F-13108 Saint Paul Lez Durance Cedex (France); Thomas, E. [Association EURATOM-CEA, DSM, Departement Recherche Fusion Controlee, CEA/Cadarache, bat 506, F-13108 Saint Paul Lez Durance Cedex (France); Houtte, D. van [Association EURATOM-CEA, DSM, Departement Recherche Fusion Controlee, CEA/Cadarache, bat 506, F-13108 Saint Paul Lez Durance Cedex (France); Zaccaria, P. [CONSORZIO RFX Association EURATOM-ENEA, Corso Stati Uniti 4, I-35127 Padova (Italy); Antoni, V. [CONSORZIO RFX Association EURATOM-ENEA, Corso Stati Uniti 4, I-35127 Padova (Italy); Bello, S. Dal; Marcuzzi, D. [CONSORZIO RFX Association EURATOM-ENEA, Corso Stati Uniti 4, I-35127 Padova (Italy); Antipenkov, A.; Day, C.; Dremel, M. [FZK, Institut fuer Technische Physik, Karlsruhe 76021 (Germany); Mondino, P.L. [EFDA CSU, Max-Planck-Institut fuer Plasma Physik Boltzmannstr. 2, D-85748 Garching (Germany)

    2005-11-15

    The CEA Association is involved, in close collaboration with ENEA, FZK, IPP and UKAEA European Associations, in the first ITER neutral beam (NB) injector and the ITER neutral beam test facility design (EFDA task ref. TW3-THHN-IITF1). A total power of about 50 MW will have to be removed in steady state on the neutral beam test facility (NBTF). The main purpose of this task is to make progress with the detailed design of the first ITER NB injector and to start the conceptual design of the ITER NBTF. The general infrastructure layout of a generic site for the NBTF includes the test facility itself equipped with a dedicated beamline vessel [P.L. Zaccaria, et al., Maintenance schemes for the ITER neutral beam test facility, this conference] and integration studies of associated auxiliaries such as cooling plant, cryoplant and forepumping system.

  14. Initial Testing of the Stainless Steel NaK-Cooled Circuit (SNaKC)

    Science.gov (United States)

    Garber, Anne; Godfroy, Thomas

    2007-01-01

    An actively pumped alkali metal flow circuit, designed and fabricated at the NASA Marshall Space Flight Center, is currently undergoing testing in the Early Flight Fission Test Facility (EFF-TF). Sodium potassium (NaK) was selected as the primary coolant. Basic circuit components include: simulated reactor core, NaK to gas heat exchanger, electromagnetic liquid metal pump, liquid metal flowmeter, load/drain reservoir, expansion reservoir, test section, and instrumentation. Operation of the circuit is based around the 37-pin partial-array core (pin and flow path dimensions are the same as those in a full core), designed to operate at 33 kWt. This presentation addresses the construction, fill and initial testing of the Stainless Steel NaK-Cooled Circuit (SNaKC).

  15. Design, fabrication, and testing of a helium-cooled module for the ITER divertor

    Energy Technology Data Exchange (ETDEWEB)

    Baxi, C.B.; Smith, J.P.; Youchison, D.

    1994-08-01

    The International Thermonuclear Reactor (ITER) will have a single-null divertor with total power flow of 200 MW and a peak heat flux of about 5 MW/m{sup 2}. The reference coolant for the divertor is water. However, helium is a viable alternative and offers advantages from safety considerations, such as excellent radiation stability and chemical inertness. In order to prove the feasibility of helium cooling at ITER relevant heat flux conditions, General Atomics designed, fabricated, and tested a helium-cooled divertor module. The module was made from dispersion strengthened copper, with a heat flux surface 25 mm wide and 80 mm long, designed for twice the ITER divertor heat flux. Different techniques were examined to enhance the heat transfer, which in turn reduced the flow and pumping power required to cool the module. It was concluded that an extended surface was the most practical solution. An optimization study was performed to find the best extended surface parameters. The optimum extended surface geometry consisted of fins: 10 mm high, 0.4 mm thick with a 1 mm pitch. It was estimated to require a pumping power of 150 W to remove 20 kW of power. This is more than an order of magnitude reduction in pumping power requirement, compared to smooth surface. The module was fabricated by electric discharge machining (EDM) process. The testing was carried out at SNLA during August 1993. The testing confirmed the design calculations. The peak heat flux during the test was 10 MW/m{sup 2} applied over a surface area of 20 cm{sup 2}. The pumping power calculated from flow rate and pressure drop measurement was about 160 W, which was less than 1% of the power removed. It is planned to test the module to higher temperature limits and higher heat fluxes during coming months. As a result of this effort we conclude that helium cooling of the ITER divertor is feasible without requiring a very large helium pressure or a large pumping power.

  16. An Experimental Test Facility to Support Development of the Fluoride Salt Cooled High Temperature Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Yoder Jr, Graydon L [ORNL; Aaron, Adam M [ORNL; Cunningham, Richard Burns [University of Tennessee, Knoxville (UTK); Fugate, David L [ORNL; Holcomb, David Eugene [ORNL; Kisner, Roger A [ORNL; Peretz, Fred J [ORNL; Robb, Kevin R [ORNL; Wilgen, John B [ORNL; Wilson, Dane F [ORNL

    2014-01-01

    The need for high-temperature (greater than 600 C) energy exchange and delivery systems is significantly increasing as the world strives to improve energy efficiency and develop alternatives to petroleum-based fuels. Liquid fluoride salts are one of the few energy transport fluids that have the capability of operating at high temperatures in combination with low system pressures. The Fluoride Salt-Cooled High-Temperature Reactor design uses fluoride salt to remove core heat and interface with a power conversion system. Although a significant amount of experimentation has been performed with these salts, specific aspects of this reactor concept will require experimental confirmation during the development process. The experimental facility described here has been constructed to support the development of the Fluoride Salt Cooled High Temperature Reactor concept. The facility is capable of operating at up to 700 C and incorporates a centrifugal pump to circulate FLiNaK salt through a removable test section. A unique inductive heating technique is used to apply heat to the test section, allowing heat transfer testing to be performed. An air-cooled heat exchanger removes added heat. Supporting loop infrastructure includes a pressure control system; trace heating system; and a complement of instrumentation to measure salt flow, temperatures, and pressures around the loop. The initial experiment is aimed at measuring fluoride salt heat transfer inside a heated pebble bed similar to that used for the core of the pebble bed advanced high-temperature reactor. This document describes the details of the loop design, auxiliary systems used to support the facility, the inductive heating system, and facility capabilities.

  17. Optimized Heat Pipe Backup Cooling System Tested with a Stirling Convertor

    Science.gov (United States)

    Schwendeman, Carl L.; Tarau, Calin; Schifer, Nicholas A.; Anderson, William G.; Garner, Scott

    2016-01-01

    In a Stirling Radioisotope Power System (RPS), heat must be continuously removed from the General Purpose Heat Source (GPHS) modules to maintain the modules and surrounding insulation at acceptable temperatures. The Stirling convertor normally provides this cooling. If the Stirling convertor stops in the current system, the insulation is designed to spoil, preventing damage to the GPHS at the cost of an early termination of the mission. An alkali-metal variable conductance heat pipe (VCHP) can be used to passively allow multiple stops and restarts of the Stirling convertor by bypassing the heat during stops. In a previous NASA Small Business Innovation Research (SBIR) Program, Advanced Cooling Technologies, Inc. (ACT) developed a series of sodium VCHPs as backup cooling systems for the Stirling RPS. In 2012, one of these VCHPs was successfully tested at NASA Glenn Research Center with a Stirling convertor as an Advanced Stirling Radioisotope Generator (ASRG) backup cooling system. The prototype; however, was not optimized and did not reflect the final heat rejection path. ACT through further funding has developed a semioptimized prototype with the finalized heat path for testing at Glenn with a Stirling convertor. The semioptimized system features a two-phase radiator and is significantly smaller and lighter than the prior prototype to reflect a higher level of flight readiness. The VCHP is designed to activate and remove heat from the GPHS during stoppage with a small temperature increase from the nominal vapor temperature. This small temperature increase from nominal is low enough to avoid risking standard ASRG operation and spoiling of the multilayer insulation (MLI). The VCHP passively allows the Stirling convertor to be turned off multiple times during a mission with potentially unlimited off durations. Having the ability to turn the Stirling off allows for the Stirling to be reset and reduces vibrations on the platform during sensitive measurements or

  18. Standard Test Method for Measuring Heat Flux Using a Water-Cooled Calorimeter

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers the measurement of a steady heat flux to a given water-cooled surface by means of a system energy balance. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  19. Manufacturing and thermomechanical testing of actively cooled all beryllium high heat flux test pieces

    Energy Technology Data Exchange (ETDEWEB)

    Vasiliev, N.N.; Sokolov, Yu.A.; Shatalov, G.E. [and others

    1995-09-01

    One of the problems affiliated to ITER high heat flux elements development is a problem of interface of beryllium protection with heat sink routinely made of copper alloys. To get rid of this problem all beryllium elements could be used as heat receivers in places of enhanced thermal loads. In accordance with this objectives four beryllium test pieces of two types have been manufactured in {open_quotes}Institute of Beryllium{close_quotes} for succeeding thermomechanical testing. Two of them were manufactured in accordance with JET team design; they are round {open_quotes}hypervapotron type{close_quotes} test pieces. Another two ones are rectangular test sections with a twisted tape installed inside of the circular channel. Preliminary stress-strain analysis have been performed for both type of the test pieces. Hypervapotrons have been shipped to JET where they were tested on JET test bed. Thermomechanical testing of pieces of the type of {open_quotes}swirl tape inside of tube{close_quotes} have been performed on Kurchatov Institute test bed. Chosen beryllium grade properties, some details of manufacturing, results of preliminary stress-strain analysis and thermomechanical testing of the test pieces {open_quotes}swirl tape inside of tube{close_quotes} type are given in this report.

  20. Hydraulic and thermal testing of different helium cooled irradiation rig models for the IFMIF High Flux Test Module

    Energy Technology Data Exchange (ETDEWEB)

    Klein, Christine, E-mail: Christine.Klein@kit.edu; Arbeiter, Frederik; Martin, Thomas; Taubmann, Peter

    2016-03-15

    Highlights: • Two different single 1:1 irradiation rigs inside a mock-up container are presented. • Pressure drops in the single rig minichannels are measured. • Temperature fields are measured under different heater and flow conditions. • Predictability and reproducibility of the cooling flows can be shown. - Abstract: The hydraulic and thermal testing of two different irradiation rig models A and B, differing in the inlet nozzle design, bottom reflector length and steps inside a mock-up container is part of the HFTM validation activities which support the engineering design of the High Flux Test Module. The pressure drops for all models in the test section are measured for overall mass flow rates of 1–12 g/s and different absolute pressures of 1500 hPa and 2500 hPa at the pressure port at the inlet section. The pressure drops in different sections of the experiment and in the single rig minichannels are also measured with additional pressure ports on the surfaces of the rig models. Predictability and reproducibility of the cooling effects of the main cooling channels in the HFTM irradiation zone can be shown. Rig model B with a backward facing step is for high mass flow rates >∼7.5 g/s (this is the operation regime of the HFTM) superior to rig model A. Uniform perfusion of the multiple parallel minichannels of the irradiation rigs by helium gas is of importance to obtain uniform and predictable temperatures. Temperature fields under different heater and flow conditions have been measured.

  1. Antiviral activity of Small interfering RNAs: Specificity testing using heterologous virus reveals interferon-related effects overlooked by conventional mismatch controls

    DEFF Research Database (Denmark)

    Schyth, Brian Dall; Lorenzen, Niels; Pedersen, Finn Skou

    2006-01-01

    RNA interference by small interfering RNAs (siRNAs) is considered to be a highly specific method for knockdown of gene expression in eukaryotic cells via degradation of target mRNA. Mutated siRNA molecules with 1–4 mismatching nucleotides compared to the target mRNA are regularly used as specific...

  2. High Pressure Gas Filled RF Cavity Beam Test at the Fermilab MuCool Test Area

    Energy Technology Data Exchange (ETDEWEB)

    Freemire, Ben [Illinois Inst. of Technology, Chicago, IL (United States)

    2013-05-01

    The high energy physics community is continually looking to push the limits with respect to the energy and luminosity of particle accelerators. In the realm of leptons, only electron colliders have been built to date. Compared to hadrons, electrons lose a large amount of energy when accelerated in a ring through synchrotron radiation. A solution to this problem is to build long, straight accelerators for electrons, which has been done with great success. With a new generation of lepton colliders being conceived, building longer, more powerful accelerators is not the most enticing option. Muons have been proposed as an alternative particle to electrons. Muons lose less energy to synchrotron radiation and a Muon Collider can provide luminosity within a much smaller energy range than a comparable electron collider. This allows a circular collider to be built with higher attainable energy than any present electron collider. As part of the accelerator, but separate from the collider, it would also be possible to allow the muons to decay to study neutrinos. The possibility of a high energy, high luminosity muon collider and an abundant, precise source of neutrinos is an attractive one. The technological challenges of building a muon accelerator are many and diverse. Because the muon is an unstable particle, a muon beam must be cooled and accelerated to the desired energy within a short amount of time. This requirement places strict requisites on the type of acceleration and focusing that can be used. Muons are generated as tertiary beams with a huge phase space, so strong magnetic fields are required to capture and focus them. Radio frequency (RF) cavities are needed to capture, bunch and accelerate the muons. Unfortunately, traditional vacuum RF cavities have been shown to break down in the magnetic fields necessary for capture and focusing.

  3. The Design and Manufacturing Report of Non-Instrumented Rig for Dual-cooled Annular Fuel Irradiation Test in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dae Ho; Bang, Je Geon; Lim, Ik Sung; Kim, Sun Ki; Yang, Yong Sik; Song, Kun Woo; Seo, Chul Gyo; Park, Chan Kook

    2008-09-15

    This project is preparing to irradiation test of the developed double cooled annular fuel pellet in HANARO for pursuit advanced performance in High Performance Fuel Technology Development as a part Nuclear Mid and Long-term R and D Program. On the basis test rod is performed the nuclei property and preliminary fuel performance analysis, test rod and non-instrumented rig designed and manufactured for irradiation test in HANARO OR hole. This non- instrumented rig was confirmed the compatibility of HANARO and the integrity of rig structure, and satisfied the quality assurance requirements. This non- instrumented rig is adopt to the irradiation test for double cooled annular fuel pellet in HANARO.

  4. Test case specifications for coupled neutronics-thermal hydraulics calculation of Gas-cooled Fast Reactor

    Science.gov (United States)

    Osuský, F.; Bahdanovich, R.; Farkas, G.; Haščík, J.; Tikhomirov, G. V.

    2017-01-01

    The paper is focused on development of the coupled neutronics-thermal hydraulics model for the Gas-cooled Fast Reactor. It is necessary to carefully investigate coupled calculations of new concepts to avoid recriticality scenarios, as it is not possible to ensure sub-critical state for a fast reactor core under core disruptive accident conditions. Above mentioned calculations are also very suitable for development of new passive or inherent safety systems that can mitigate the occurrence of the recriticality scenarios. In the paper, the most promising fuel material compositions together with a geometry model are described for the Gas-cooled fast reactor. Seven fuel pin and fuel assembly geometry is proposed as a test case for coupled calculation with three different enrichments of fissile material in the form of Pu-UC. The reflective boundary condition is used in radial directions of the test case and vacuum boundary condition is used in axial directions. During these condition, the nuclear system is in super-critical state and to achieve a stable state (which is numerical representation of operational conditions) it is necessary to decrease the reactivity of the system. The iteration scheme is proposed, where SCALE code system is used for collapsing of a macroscopic cross-section into few group representation as input for coupled code NESTLE.

  5. Gas cooled fast breeder reactor design for a circulator test facility (modified HTGR circulator test facility)

    Energy Technology Data Exchange (ETDEWEB)

    1979-10-01

    A GCFR helium circulator test facility sized for full design conditions is proposed for meeting the above requirements. The circulator will be mounted in a large vessel containing high pressure helium which will permit testing at the same power, speed, pressure, temperature and flow conditions intended in the demonstration plant. The electric drive motor for the circulator will obtain its power from an electric supply and distribution system in which electric power will be taken from a local utility. The conceptual design decribed in this report is the result of close interaction between the General Atomic Company (GA), designer of the GCFR, and The Ralph M. Parson Company, architect/engineer for the test facility. A realistic estimate of total project cost is presented, together with a schedule for design, procurement, construction, and inspection.

  6. Test of a cryogenic set-up for a 10 meter long liquid nitrogen cooled superconducting power cable

    DEFF Research Database (Denmark)

    Træholt, Chresten; Rasmussen, Carsten; Kühle (fratrådt), Anders Van Der Aa;

    2000-01-01

    High temperature superconducting power cables may be cooled by a forced flow of sub-cooled liquid nitrogen. One way to do this is to circulate the liquid nitrogen (LN2) by means of a mechanical pump through the core of the cable and through a sub-cooler.Besides the cooling station, the cryogenics...... cable. We report on our experimental set-up for testing a 10 meter long high temperature superconducting cable with a critical current of 3.2 kA at 77K. The set-up consists of a custom designed cable end termination, current lead, coolant feed-through, liquid nitrogen closed loop circulation system...

  7. Development of the Water Cooled Ceramic Breeder Test Blanket Module in Japan

    Energy Technology Data Exchange (ETDEWEB)

    Enoeda, Mikio, E-mail: enoeda.mikio@jaea.go.jp [Japan Atomic Energy Agency, Naka-shi, Ibaraki-ken 311-0193 (Japan); Tanigawa, Hisashi; Hirose, Takanori; Suzuki, Satoshi; Ochiai, Kentaro; Konno, Chikara; Kawamura, Yoshinori; Yamanishi, Toshihiko; Hoshino, Tsuyoshi; Nakamichi, Masaru; Tanigawa, Hiroyasu; Ezato, Koichiro; Seki, Yohji; Yoshikawa, Akira; Tsuru, Daigo; Akiba, Masato [Japan Atomic Energy Agency, Naka-shi, Ibaraki-ken 311-0193 (Japan)

    2012-08-15

    The development of a Water Cooled Ceramic Breeder (WCCB) Test Blanket Module (TBM) is being performed as one of the most important steps toward DEMO blanket in Japan. For the TBM testing and evaluation toward DEMO blanket, the module fabrication technology development by a candidate structural material, reduced activation martensitic/ferritic steel, F82H, is one of the most critical items from the viewpoint of realization of TBM testing in ITER. In Japan, fabrication of a real scale first wall, side walls, a breeder pebble bed box and assembling of the first wall and side walls have succeeded. Recently, the real scale partial mockup of the back wall was fabricated. The fabrication procedure of the back wall, whose thickness is up to 90 mm, was confirmed toward the fabrication of the real scale back wall by F82H. Important key technologies are almost clarified for the fabrication of the real scale TBM module mockup. From the view point of testing and evaluation, development of the technology of the blanket tritium recovery, development of advanced breeder and multiplier pebbles and the development of the blanket neutronics measurement technology are also performed. Also, tritium production and recovery test using D-T neutron in the Fusion Neutronics Source (FNS) facility has been started as the verification test of tritium production performance. This paper overviews the recent achievements of the development of the WCCB TBM in Japan.

  8. An Analysis of Testing Requirements for Fluoride Salt Cooled High Temperature Reactor Components

    Energy Technology Data Exchange (ETDEWEB)

    Holcomb, David Eugene [ORNL; Cetiner, Sacit M [ORNL; Flanagan, George F [ORNL; Peretz, Fred J [ORNL; Yoder Jr, Graydon L [ORNL

    2009-11-01

    This report provides guidance on the component testing necessary during the next phase of fluoride salt-cooled high temperature reactor (FHR) development. In particular, the report identifies and describes the reactor component performance and reliability requirements, provides an overview of what information is necessary to provide assurance that components will adequately achieve the requirements, and then provides guidance on how the required performance information can efficiently be obtained. The report includes a system description of a representative test scale FHR reactor. The reactor parameters presented in this report should only be considered as placeholder values until an FHR test scale reactor design is completed. The report focus is bounded at the interface between and the reactor primary coolant salt and the fuel and the gas supply and return to the Brayton cycle power conversion system. The analysis is limited to component level testing and does not address system level testing issues. Further, the report is oriented as a bottom-up testing requirements analysis as opposed to a having a top-down facility description focus.

  9. Testing candidate interlayers for an enhanced water-cooled divertor target

    Energy Technology Data Exchange (ETDEWEB)

    Hancock, David, E-mail: david.hancock@ccfe.ac.uk [CCFE, Culham Science Centre, Oxfordshire OX14 3DB (United Kingdom); Barrett, Tom; Foster, James; Fursdon, Mike; Keech, Gregory; McIntosh, Simon; Timmis, William [CCFE, Culham Science Centre, Oxfordshire OX14 3DB (United Kingdom); Rieth, Michael; Reiser, Jens [Karlsruhe Institute of Technology, IAM-AWP, P.O. Box 3640, 76021 Karlsruhe (Germany)

    2015-10-15

    Highlights: • We introduce an optimised divertor target concept: the “Thermal Break”. • We suggest a candidate interlayer material for this concept: FeltMetal. • We describe a bespoke rig for testing the thermal conductivity of this material. • We present preliminary results for a number of samples. - Abstract: The design of a divertor target for DEMO remains one of the most challenging engineering tasks to be overcome on the path to fusion power. Under the European DEMO programme, a promising concept known as Thermal Break has been developed at CCFE. This concept is a variation of the ITER tungsten divertor in which the pure Copper interlayer between Copper Chrome Zirconium coolant pipe and Tungsten monoblock armour is replaced with a low thermal conductivity compliant interlayer, with the aim of reducing the thermal mismatch stress between the armour and structure. One candidate material for this interlayer is FeltMetal™ (Technetics Group, USA). This material consists of an amorphous matrix of fine copper wires which are sintered onto a thin copper foil, creating a sheet of approximately 1 mm thickness. FeltMetal has been successfully used for many years to provide compliant sliding electrical contacts for the MAST TF coils and on ALCATOR C-Mod and extensive material testing has therefore been undertaken to quantify thermal and mechanical properties. These tests, however, have not been performed under vacuum or DEMO-relevant conditions. A bespoke experimental test rig has therefore been designed and constructed with which to measure the interlayer thermal conductance as a function of temperature and pressure under vacuum conditions. The design of this apparatus and the results of experiments on FeltMetal as well as other candidate interlayers are presented here. In parallel, joint mockups using the candidate interlayers have been prepared and Thermal Break divertor target mockups have been manufactured, requiring the development of a dedicated

  10. Hydraulic testing of helium cooled irradiation rigs of the IFMIF High Flux Test Module

    Energy Technology Data Exchange (ETDEWEB)

    Klein, Christine, E-mail: Christine.Klein@kit.edu [Karlsruhe Institute of Technology, INR, Eggenstein-Leopoldshafen (Germany); Arbeiter, Frederik; Jackowski, Thomas; Martin, Thomas; Schlindwein, Georg [Karlsruhe Institute of Technology, INR, Eggenstein-Leopoldshafen (Germany)

    2012-08-15

    Highlights: Black-Right-Pointing-Pointer Uniform perfusion of the multiple parallel minichannels of the rig model B by helium gas, which is of importance to obtain uniform and predictable temperatures, could be verified by measuring the mean velocity profiles of the rectangular jets are measured using hot-wire anemometry. Black-Right-Pointing-Pointer The pressure drop in the test section with rig model B was measured and delivers data for the validation of computational fluid dynamics (CFD) modeling approach for application in the IFMIF High Flux Test Module. The pressure drop depends significantly on the pressure level; acceleration resulting from the volumetric expansion of helium gas has to be modeled carefully in simulations. Black-Right-Pointing-Pointer Measurements with strain gage show the pressure depending deformation of the compartment container without the rig. The results agree well with simulations and approximation calculations. - Abstract: The hydraulic testing of a single 1:1 irradiation rig inside a mock-up container is part of the validation activities which support the engineering design of the High Flux Test Module. Uniform perfusion of the multiple parallel minichannels of the irradiation rigs by helium gas is of importance to obtain uniform and predictable temperatures. To evaluate the uniform distribution to the different parallel minichannels, the mean velocity profiles of the rectangular jets are measured using hot-wire anemometry. The velocity profiles show a symmetric and constant distribution of the mass flow to the parallel minichannels. The pressure drop in the test section with one of the candidate rig shapes is measured. The pressure drop depends significantly on the entrance pressure level; acceleration resulting from the volumetric expansion of helium gas has to be taken into account in simulations. Measurements with strain gage show the pressure depending deformation of the compartment container without the rig. The results agree

  11. Mock-up Test for Isotope Target Transport and Cooling System

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Sang-pil; Kwon, Hyeok-jung; Kim, Han-sung; Cho, Yong-sub; Chung, Bo-hyun; Seol, Kyung-tae; Song, Young-gi; Kim, Dae-il; Min, Yi-sub [KOMAC, Gyeongju (Korea, Republic of)

    2015-10-15

    In this paper, we described the design and fabrication of the test mock-up of target transport and cooling system for the isotope production by using the 100-MeV proton irradiation. For Sr-82 production, RbCl target and aluminum dummy target was prepared. These targets are contained in the target carrier, which could transported by drive chain and guide rail system. Korea multi-purpose Accelerator Complex (KOMAC) has a plan to construct the new proton beam irradiation facility for the production of radioisotopes. Sr-82 and Cu-67 were selected as the target isotope in this facility, they are promising isotope for the PET imaging and cancer therapy. To produce Sr-82 by 100- MeV proton irradiation, RbCl were chosen as a target material due to their high melting point and easy separation. For the facility construction, we have designed targetry system which consists of target, target transport system and target cooling system. This paper describes the details of targetry system.

  12. Steep-Slope Assembly Testing of Clay and Concrete Tile With and Without Cool Pigmented Colors

    Energy Technology Data Exchange (ETDEWEB)

    Miller, William A [ORNL

    2005-11-01

    Cool color pigments and sub-tile venting of clay and concrete tile roofs significantly impact the heat flow crossing the roof deck of a steep-slope roof. Field measures for the tile roofs revealed a 70% drop in the peak heat flow crossing the deck as compared to a direct-nailed asphalt shingle roof. The Tile Roofing Institute (TRI) and its affiliate members are keenly interested in documenting the magnitude of the drop for obtaining solar reflectance credits with state and federal "cool roof" building efficiency standards. Tile roofs are direct-nailed or are attached to a deck with batten or batten and counter-batten construction. S-Misson clay and concrete tile roofs, a medium-profile concrete tile roof, and a flat slate tile roof were installed on fully nstrumented attic test assemblies. Temperature measures of the roof, deck, attic, and ceiling, heat flows, solar reflectance, thermal emittance, and the ambient weather were recorded for each of the tile roofs and also on an adjacent attic cavity covered with a conventional pigmented and directnailed asphalt shingle roof. ORNL measured the tile's underside temperature and the bulk air temperature and heat flows just underneath the tile for batten and counter-batten tile systems and compared the results to the conventional asphalt shingle.

  13. Vortex Diode Analysis and Testing for Fluoride Salt-Cooled High-Temperature Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Yoder Jr, Graydon L [ORNL; Elkassabgi, Yousri M. [Texas A& M University, Kingsville; De Leon, Gerardo I. [Texas A& M University, Kingsville; Fetterly, Caitlin N. [Texas A& M University, Kingsville; Ramos, Jorge A. [Texas A& M University, Kingsville; Cunningham, Richard Burns [University of Tennessee, Knoxville (UTK)

    2012-02-01

    Fluidic diodes are presently being considered for use in several fluoride salt-cooled high-temperature reactor designs. A fluidic diode is a passive device that acts as a leaky check valve. These devices are installed in emergency heat removal systems that are designed to passively remove reactor decay heat using natural circulation. The direct reactor auxiliary cooling system (DRACS) uses DRACS salt-to-salt heat exchangers (DHXs) that operate in a path parallel to the core flow. Because of this geometry, under normal operating conditions some flow bypasses the core and flows through the DHX. A flow diode, operating in reverse direction, is-used to minimize this flow when the primary coolant pumps are in operation, while allowing forward flow through the DHX under natural circulation conditions. The DRACSs reject the core decay heat to the environment under loss-of-flow accident conditions and as such are a reactor safety feature. Fluidic diodes have not previously been used in an operating reactor system, and therefore their characteristics must be quantified to ensure successful operation. This report parametrically examines multiple design parameters of a vortex-type fluidic diode to determine the size of diode needed to reject a particular amount of decay heat. Additional calculations were performed to size a scaled diode that could be tested in the Oak Ridge National Laboratory Liquid Salt Flow Loop. These parametric studies have shown that a 152.4 mm diode could be used as a test article in that facility. A design for this diode is developed, and changes to the loop that will be necessary to test the diode are discussed. Initial testing of a scaled flow diode has been carried out in a water loop. The 150 mm diode design discussed above was modified to improve performance, and the final design tested was a 171.45 mm diameter vortex diode. The results of this testing indicate that diodicities of about 20 can be obtained for diodes of this size. Experimental

  14. Develop and test an Internally Cooled, Cabled Superconductor (ICCS) for large scale MHD magnets

    Science.gov (United States)

    Marston, P. G.; Hale, J. R.; Dawson, A. M.

    1990-04-01

    The work included four principal tasks: (1) development of a design requirements definition for a retrofit MHD magnet system; (2) analysis of an internally cooled, cabled superconductor (ICCS) to use in that design; (3) design of an experiment to test a subscale version of that conductor, which is a NbTi, copper stabilized superconductor; and (4) proof-of-concept testing of the conductor. The program was carried forth through the third task with very successful development and test of a conventional ICCS conductor with 27 multifilamentary copper-superconductor composite strands and a new concept conductor in which, in each triplet, two strands were pure copper and the third strand was a multifilamentary composite. In reviewing the magnet design and the premises for the conductor design it became obvious that an extra barrier might be highly effective in enhancing magnet stability and protection. This concept was developed and a sample conductor manufactured and tested in comparison with an identical conductor lacking such an additional barrier. Results of these conductor tests confirm the potential value of such a barrier. Since the work of tasks 1 through 3 has been reported in detail in quarterly and semiannual reports, as well as in special reports prepared throughout the course of this project, this report reviews early work briefly and then discusses this last phase in great detail.

  15. Design and Test of Advanced Thermal Simulators for an Alkali Metal-Cooled Reactor Simulator

    Science.gov (United States)

    Garber, Anne E.; Dickens, Ricky E.

    2011-01-01

    The Early Flight Fission Test Facility (EFF-TF) at NASA Marshall Space Flight Center (MSFC) has as one of its primary missions the development and testing of fission reactor simulators for space applications. A key component in these simulated reactors is the thermal simulator, designed to closely mimic the form and function of a nuclear fuel pin using electric heating. Continuing effort has been made to design simple, robust, inexpensive thermal simulators that closely match the steady-state and transient performance of a nuclear fuel pin. A series of these simulators have been designed, developed, fabricated and tested individually and in a number of simulated reactor systems at the EFF-TF. The purpose of the thermal simulators developed under the Fission Surface Power (FSP) task is to ensure that non-nuclear testing can be performed at sufficiently high fidelity to allow a cost-effective qualification and acceptance strategy to be used. Prototype thermal simulator design is founded on the baseline Fission Surface Power reactor design. Recent efforts have been focused on the design, fabrication and test of a prototype thermal simulator appropriate for use in the Technology Demonstration Unit (TDU). While designing the thermal simulators described in this paper, effort were made to improve the axial power profile matching of the thermal simulators. Simultaneously, a search was conducted for graphite materials with higher resistivities than had been employed in the past. The combination of these two efforts resulted in the creation of thermal simulators with power capacities of 2300-3300 W per unit. Six of these elements were installed in a simulated core and tested in the alkali metal-cooled Fission Surface Power Primary Test Circuit (FSP-PTC) at a variety of liquid metal flow rates and temperatures. This paper documents the design of the thermal simulators, test program, and test results.

  16. Film Cooled Recession of SiC/SiC Ceramic Matrix Composites: Test Development, CFD Modeling and Experimental Observations

    Science.gov (United States)

    Zhu, Dongming; Sakowski, Barbara A.; Fisher, Caleb

    2014-01-01

    SiCSiC ceramic matrix composites (CMCs) systems will play a crucial role in next generation turbine engines for hot-section component applications because of their ability to significantly increase engine operating temperatures, reduce engine weight and cooling requirements. However, the environmental stability of Si-based ceramics in high pressure, high velocity turbine engine combustion environment is of major concern. The water vapor containing combustion gas leads to accelerated oxidation and corrosion of the SiC based ceramics due to the water vapor reactions with silica (SiO2) scales forming non-protective volatile hydroxide species, resulting in recession of the ceramic components. Although environmental barrier coatings are being developed to help protect the CMC components, there is a need to better understand the fundamental recession behavior of in more realistic cooled engine component environments.In this paper, we describe a comprehensive film cooled high pressure burner rig based testing approach, by using standardized film cooled SiCSiC disc test specimen configurations. The SiCSiC specimens were designed for implementing the burner rig testing in turbine engine relevant combustion environments, obtaining generic film cooled recession rate data under the combustion water vapor conditions, and helping developing the Computational Fluid Dynamics (CFD) film cooled models and performing model validation. Factors affecting the film cooled recession such as temperature, water vapor concentration, combustion gas velocity, and pressure are particularly investigated and modeled, and compared with impingement cooling only recession data in similar combustion flow environments. The experimental and modeling work will help predict the SiCSiC CMC recession behavior, and developing durable CMC systems in complex turbine engine operating conditions.

  17. Electron lenses and cooling for the Fermilab Integrable Optics Test Accelerator

    CERN Document Server

    Stancari, G; Lebedev, V; Nagaitsev, S; Prebys, E; Valishev, A

    2015-01-01

    Recently, the study of integrable Hamiltonian systems has led to nonlinear accelerator lattices with one or two transverse invariants and wide stable tune spreads. These lattices may drastically improve the performance of high-intensity machines, providing Landau damping to protect the beam from instabilities, while preserving dynamic aperture. The Integrable Optics Test Accelerator (IOTA) is being built at Fermilab to study these concepts with 150-MeV pencil electron beams (single-particle dynamics) and 2.5-MeV protons (dynamics with self fields). One way to obtain a nonlinear integrable lattice is by using the fields generated by a magnetically confined electron beam (electron lens) overlapping with the circulating beam. The required parameters are similar to the ones of existing devices. In addition, the electron lens will be used in cooling mode to control the brightness of the proton beam and to measure transverse profiles through recombination. More generally, it is of great interest to investigate whet...

  18. Cooling Tests of the NectarCAM camera for the Cherenkov Telescope Array

    CERN Document Server

    Moulin, E; Durand, D; Feirreira, O; Fesquet, M; Giebels, B; Glicenstein, J -F; Loiseau, D; Louis, F; Nunio, F; Rateau, S; consortia, CTA

    2015-01-01

    The NectarCAM is a camera proposed for the medium-sized telescopes in the framework of the Cherenkov Telescope Array (CTA), the next-generation observatory for very-high-energy gamma-ray astronomy. The cameras are designed to operate in an open environment and their mechanics must provide protection for all their components under the conditions defined for the CTA observatory. In order to operate in a stable environment and ensure the best physics performance, each NectarCAM will be enclosed in a slightly overpressurized, nearly air-tight, camera body, to prevent dust and water from entering. The total power dissipation will be ~7.7 kW for a 1855-pixel camera. The largest fraction is dissipated by the readout electronics in the modules. We present the design and implementation of the cooling system together with the test bench results obtained on the NectarCAM thermal demonstrator.

  19. Design and performance test of miniature capillary pumped loop for electronics cooling

    Institute of Scientific and Technical Information of China (English)

    万珍平; 皮丕辉; 付永清; 汤勇

    2008-01-01

    Considering two characteristics of compact heat dissipation room and high heat flux, a novel miniature capillary pumped loop (MCPL) for electronics cooling was proposed. MCPL consists of evaporator, condenser, vapor and liquid line dissipates heat by boiling and condensation of working fluids with no extra power consumption. Working fluid circulation is ensured by vapor pressure and capillary head. Saturated wick screens vapor and liquid, and ensures one-way flow of working fluid with no extra valve. In order to promote heat dissipation capacity of MCPL, the intensified boiling and condensation structures are embedded into evaporator and condenser respectively, which are useful to increasing boiling and condensation efficiency. Startup and run characteristics are tested by experiments in the condition of different power inputs and working fluids. MCPL is capable of dissipating 80 W of thermal energy and keeping the bottom substrate temperature of evaporator at 80 ℃.

  20. High power RF test of an 805 MHz RF cavity for a muon cooling channel

    Science.gov (United States)

    Li, D.; Corlett, J.; MacGill, R.; Rimmer, R.; Wallig, J.

    2002-05-01

    We present recent high power RF test results on an 805 MHz cavity for a muon cooling experiment at Lab G in Fermilab. In order to achieve high accelerating gradient for large transverse emittance muon beams, the cavity design has adopted a pillbox like shape with 16 cm diameter beam iris covered by thin Be windows, which are demountable to allow for RF tests of different windows. The cavity body is made from copper with stiff stainless steel rings brazed to the cavity body for window attachments. View ports and RF probes are available for visual inspections of the surface of windows and cavity and measurement of the field gradient. Maximum of three thermo-couples can be attached to the windows for monitoring the temperature gradient on the windows caused by RF heating. The cavity was measured to have Q0 of about 15,000 with copper windows and coupling constant of 1.3 before final assembling. A 12 MW peak power klystron is available at Lab G in Fermilab for the high power test. The cavity and coupler designs were performed using the MAFIA code in the frequency and the time domain. Numerical simulation results and cold test measurements on the cavity and coupler will be presented for comparisons.

  1. High power RF test of an 805 MHz RF cavity for a muon cooling channel

    Energy Technology Data Exchange (ETDEWEB)

    Li, Derun; Corlett, J.; MacGill, R.; Rimmer, R.; Wallig, J.; Zisman, M.; Moretti, A.; Qian, Z.; Wu, V.; Summers, D.; Norem, J.

    2002-05-30

    We present recent high power RF test results on an 805 MHz cavity for a muon cooling experiment at Lab G in Fermilab. In order to achieve high accelerating gradient for large transverse emittance muon beams, the cavity design has adopted a pillbox like shape with 16 cm diameter beam iris covered by thin Be windows, which are demountable to allow for RF tests of different windows. The cavity body is made from copper with stiff stainless steel rings brazed to the cavity body for window attachments. View ports and RF probes are available for visual inspections of the surface of windows and cavity and measurement of the field gradient. Maximum of three thermo-couples can be attached to the windows for monitoring the temperature gradient on the windows caused by RF heating. The cavity was measured to have Q{sub 0} of about 15,000 with copper windows and coupling constant of 1.3 before final assembling. A 12 MW peak power klystron is available at Lab G in Fermilab for the high power test. The cavity and coupler designs were performed using the MAFIA code in the frequency and the time domain. Numerical simulation results and cold test measurements on the cavity and coupler will be presented for comparisons.

  2. Mammalian mismatch repair

    DEFF Research Database (Denmark)

    Pena Diaz, Javier; Jiricny, Josef

    2012-01-01

    A considerable surge of interest in the mismatch repair (MMR) system has been brought about by the discovery of a link between Lynch syndrome, an inherited predisposition to cancer of the colon and other organs, and malfunction of this key DNA metabolic pathway. This review focuses on recent...... advances in our understanding of the molecular mechanisms of canonical MMR, which improves replication fidelity by removing misincorporated nucleotides from the nascent DNA strand. We also discuss the involvement of MMR proteins in two other processes: trinucleotide repeat expansion and antibody maturation...

  3. Test Set-Up for the Cooling of Heavy Magnets by Controlled Way Down to 77 K

    Science.gov (United States)

    Bajas, H.; Bajko, M.; Benda, V.; Bottura, L.; Bourgeois, G.; Charrondiere, M.; Chiuchiolo, A.; Ferracin, P.; Guinchard, M.; Garcia, J. E. Muñoz; Giloux, C.; Juchno, M.; Perez, J. C.; de Rijk, G.; Viret, P.; Ziemianski, D. T.

    In the scope of the High Field Magnets work package of the European FP7-EuCARD project, the structure of the future dipole magnet RMC and FRESCA2 has been tested at liquid nitrogen temperature replacing the actual Nb3Sn-based coils by aluminium dummy coils. Such test aims at measuring during the cooling the evolution of the mechanical stresses and the temperatures via compensated strain gauges and carbon-ceramic sensors placed at various locations on the structure (shell, rods, yokes, dummy coils). These measurements help assess the thermo-mechanical behaviour of the assembly for different applied pre-stresses and validate the finite element simulation of the magnet cooling before including the definitive brittle Nb3Sn coils. For this purpose, a specific cool-down/warm-up nitrogen test station has been built up at CERN in order to control the required maximum temperature gradient in the magnet during both cooling and warming. In this paper, we present in detail the test facility, the instrumentation along with the automatic process control system. An analytical approach computing the expected temperature evolution during a thermal cycle is introduced and the temperature measurements related to the magnets cooling down to 77 K and warm up to room temperature are presented.

  4. DESIGN CHARACTERISTICS OF THE IDAHO NATIONAL LABORATORY HIGH-[TEMPERATURE GAS-COOLED TEST REACTOR

    Energy Technology Data Exchange (ETDEWEB)

    Sterbentz, James; Bayless, Paul; Strydom, Gerhard; Kumar, Akansha; Gougar, Hans

    2016-11-01

    A point design for a graphite-moderated, high-temperature, gas-cooled test reactor (HTG TR) has been developed by Idaho National Laboratory (INL) as part of a United States (U.S.) Department of Energy (DOE) initiative to explore and potentially expand the existing U.S. test reactor capabilities. This paper provides a summary of the design and its main attributes. The 200 MW HTG TR is a thermal-neutron spectrum reactor composed of hexagonal prismatic fuel and graphite reflector blocks. Twelve fuel columns (96 fuel blocks total and 6.34 m active core height) are arranged in two hexagonal rings to form a relatively compact, high-power density, annular core sandwiched between inner, outer, top, and bottom graphite reflectors. The HTG-TR is designed to operate at 7 MPa with a coolant inlet/outlet temperature of 325°C/650°C, and utilizes TRISO particle fuel from the DOE AGR Program with 425 ?m uranium oxycarbide (UCO) kernels and an enrichment of 15.5 wt% 235U. The primary mission of the HTG TR is material irradiation and therefore the core has been specifically designed and optimized to provide the highest possible thermal and fast neutron fluxes. The highest thermal neutron flux (3.90E+14 n/cm2s) occurs in the outer reflector, and the maximum fast flux levels (1.17E+14 n/cm2s) are produced in the central reflector column where most of the graphite has been removed. Due to high core temperatures under accident conditions, all the irradiation test facilities have been located in the inner and outer reflectors where fast flux levels decline. The core features a large number of irradiation positions with large test volumes and long test lengths, ideal for thermal neutron irradiation of large test articles. The total available test volume is more than 1100 liters. Up to four test loop facilities can be accommodated with pressure tube boundaries to isolate test articles and test fluids (e.g., liquid metal, liquid salt, light water) from the helium primary coolant system.

  5. Develop and test an internally cooled, cabled superconductor (ICCS) for large scale MHD magnets

    Energy Technology Data Exchange (ETDEWEB)

    Marston, P.G.; Hale, J.R.; Dawson, A.M.

    1990-04-30

    The work conducted under DOE/PETC Contract DE-AC22-84PC70512 has included four principal tasks, (1) development of a Design Requirements Definition for a retrofit MHD magnet system, (2) analysis of an internally cooled, cabled superconductor (ICCS) to use in that design, (3) design of an experiment to test a subscale version of that conductor, which is a NbTi, copper stabilized superconductor, and (4) proof-of-concept testing of the conductor. The program was carried forth through the third task with very successful development and test of a conventional ICCS conductor with 27 multifilamentary copper-superconductor composite strands and a new concept conductor in which, in each triplet, two strands were pure copper and the third strand was a multifilamentary composite. In reviewing the magnet design and the premises for the conductor design it became obvious that, since the principal source of perturbation in MHD magnets derives from slippage between coils, or between turns in a coil, thereby producing frictional heat which must flow through the conductor sheath and the helium to the superconductor strands, an extra barrier might be highly effective in enhancing magnet stability and protection. This concept was developed and a sample conductor manufactured and tested in comparison with an identical conductor lacking such an additional barrier. Results of these conductor tests confirm the potential value of such a barrier. As the work of tasks 1 through 3 has been reported in detail in quarterly and semiannual reports, as well as in special reports prepared throughout the course of this project, this report reviews early work briefly and then discusses this last phase in great detail. 8 refs., 36 figs.

  6. Design of the Wendelstein 7-X inertially cooled Test Divertor Unit Scraper Element

    Energy Technology Data Exchange (ETDEWEB)

    Lumsdaine, Arnold, E-mail: lumsdainea@ornl.gov [Oak Ridge National Laboratory, Oak Ridge, TN (United States); Boscary, Jean [Max Planck Institute for Plasma Physics, Garching (Germany); Fellinger, Joris [Max Planck Institute for Plasma Physics, Greifswald (Germany); Harris, Jeff [Oak Ridge National Laboratory, Oak Ridge, TN (United States); Hölbe, Hauke; König, Ralf [Max Planck Institute for Plasma Physics, Greifswald (Germany); Lore, Jeremy; McGinnis, Dean [Oak Ridge National Laboratory, Oak Ridge, TN (United States); Neilson, Hutch; Titus, Peter [Princeton Plasma Physics Lab, Princeton, NJ (United States); Tretter, Jörg [Max Planck Institute for Plasma Physics, Garching (Germany)

    2015-10-15

    Highlights: • The justification for the installation of the Test Divertor Unit Scraper Element is given. • Specially designed operational scenarios for the component are presented. • Plans for the design of the component are detailed. - Abstract: The Wendelstein 7-X stellarator is scheduled to begin operation in 2015, and to achieve full power steady-state operation in 2019. Computational simulations have indicated that for certain plasma configurations in the steady-state operation, the ends of the divertor targets may receive heat fluxes beyond their qualified technological limit. To address this issue, a high heat-flux “scraper element” (HHF-SE) has been designed that can protect the sensitive divertor target region. The surface profile of the HHF-SE has been carefully designed to meet challenging engineering requirements and severe spatial limitations through an iterative process involving physics simulations, engineering analysis, and computer aided design rendering. The desire to examine how the scraper element interacts with the plasma, both in terms of how it protects the divertor, and how it affects the neutral pumping efficiency, has led to the consideration of installing an inertially cooled version during the short pulse operation phase. This Test Divertor Unit Scraper Element (TDU-SE) would replicate the surface profile of the HHF-SE. The design and instrumentation of this component must be completed carefully in order to satisfy the requirements of the machine operation, as well as to support the possible installation of the HHF-SE for steady-state operation.

  7. Monte Carlo simulation of epitaxial growth on a (111) layer with mismatch

    Science.gov (United States)

    Tan, S.; Ghazali, A.; Lévy, J.-C. S.

    1997-04-01

    A high-temperature deposition of adatoms on a substrate with or without lattice mismatch from -10% to +10%, followed by slow cooling to a given temperature, is simulated by means of a Monte Carlo algorithm with Lennard-Jones interatomic pair potentials. Stranski-Krastanov growth is always observed with a lateral island size controlled by the lattice mismatch, while the deposition mode acts strongly on the island slope. Complete healing of the island structure never occurs before the tenth layer. The interlayer distance undergoes oscillations as a function of the layer number. This is observed for a ±10% mismatch as well as for a -5% mismatch.

  8. Construction and test of a cryocooler-cooled low-Tc SQUID gradiometer system

    NARCIS (Netherlands)

    Rijpma, A.P.; Krooshoop, H.J.G.; Lefevere, M.W.; Leeuwen, van E.P.; Holland, H.J.; Haken, ten B.; Brake, ter H.J.M.

    2008-01-01

    A cryocooler-cooled low-Tc SQUID gradiometer system was designed and constructed. It is based on a 4 K GM-cooler that is positioned several meters from the measuring head containing the SQUID sensors. The cooling power is transported by means of a circulating helium flow. Thus, there are three main

  9. Cool products for building envelope - Part I: Development and lab scale testing

    NARCIS (Netherlands)

    Revel, G.M.; Martarelli, M.; Emiliani, M.; Gozalbo, A.; Orts, M.J.; Bengochea, M.T.; Guaita Delgado, L.; Gaki, A.; Katsiapi, A.; Taxiarchou, M.; Arabatzis, I.; Fasaki, I.; Hermanns, S.

    2014-01-01

    The paper describes the methodology followed for the development of new cool products in order to widen the range of existing solutions both including coloured (even dark) materials and extending the application also to building vertical components. Cool coloured ceramic tiles and acrylic paints for

  10. Cool products for building envelope - Part I: Development and lab scale testing

    NARCIS (Netherlands)

    Revel, G.M.; Martarelli, M.; Emiliani, M.; Gozalbo, A.; Orts, M.J.; Bengochea, M.T.; Guaita Delgado, L.; Gaki, A.; Katsiapi, A.; Taxiarchou, M.; Arabatzis, I.; Fasaki, I.; Hermanns, S.

    2014-01-01

    The paper describes the methodology followed for the development of new cool products in order to widen the range of existing solutions both including coloured (even dark) materials and extending the application also to building vertical components. Cool coloured ceramic tiles and acrylic paints for

  11. Electron Lenses and Cooling for the Fermilab Integrable Optics Test Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Stancari, G. [Fermilab; Burov, A. [Fermilab; Lebedev, V. [Fermilab; Nagaitsev, S. [Fermilab; Prebys, E. [Fermilab; Valishev, A. [Fermilab

    2015-11-05

    Recently, the study of integrable Hamiltonian systems has led to nonlinear accelerator lattices with one or two transverse invariants and wide stable tune spreads. These lattices may drastically improve the performance of high-intensity machines, providing Landau damping to protect the beam from instabilities, while preserving dynamic aperture. The Integrable Optics Test Accelerator (IOTA) is being built at Fermilab to study these concepts with 150-MeV pencil electron beams (single-particle dynamics) and 2.5-MeV protons (dynamics with self fields). One way to obtain a nonlinear integrable lattice is by using the fields generated by a magnetically confined electron beam (electron lens) overlapping with the circulating beam. The required parameters are similar to the ones of existing devices. In addition, the electron lens will be used in cooling mode to control the brightness of the proton beam and to measure transverse profiles through recombination. More generally, it is of great interest to investigate whether nonlinear integrable optics allows electron coolers to exceed limitations set by both coherent or incoherent instabilities excited by space charge.

  12. Vibration test on KMRR reactor structure and primary cooling system piping

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Seung Hoh; Kim, Tae Ryong; Park, Jin Hoh; Park, Jin Suk; Ryoo, Jung Soo [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1994-10-01

    Most equipments, piping systems and reactor structures in nuclear power plants are subjected to flow induced vibration due to high temperature and high pressure coolant flowing inside or outside of the equipments, systems and structures. Because the flow induced vibration sometimes causes significant damage to reactor structures and piping systems, it is important and necessary to evaluate the vibration effect on them and to prove their structural integrity. Korea Multipurpose Research Reactor (KMRR) being constructed by KAERI is 30 MWt pool type research reactor. Since its main structures and piping systems were designed and manufactured in accordance with the standards and guidelines for commercial nuclear power plant, it was decided to evaluate their vibratory response in accordance with the standards and guidelines for commercial NPP. The objective of this vibration test is the assessment of vibration levels of KMRR reactor structure and primary cooling piping system for their structural integrity under the steady-state or transient operating condition. 38 figs, 14 tabs, 2 refs. (Author).

  13. Lattice design of the integrable optics test accelerator and optical stochastic cooling experiment at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Kafka, Gene [Illinois Inst. of Technology, Chicago, IL (United States)

    2015-05-01

    The Integrable Optics Test Accelerator (IOTA) storage ring at Fermilab will serve as the backbone for a broad spectrum of Advanced Accelerator R&D (AARD) experiments, and as such, must be designed with signi cant exibility in mind, but without compromising cost e ciency. The nonlinear experiments at IOTA will include: achievement of a large nonlinear tune shift/spread without degradation of dynamic aperture; suppression of strong lattice resonances; study of stability of nonlinear systems to perturbations; and studies of di erent variants of nonlinear magnet design. The ring optics control has challenging requirements that reach or exceed the present state of the art. The development of a complete self-consistent design of the IOTA ring optics, meeting the demands of all planned AARD experiments, is presented. Of particular interest are the precise control for nonlinear integrable optics experiments and the transverse-to-longitudinal coupling and phase stability for the Optical Stochastic Cooling Experiment (OSC). Since the beam time-of- ight must be tightly controlled in the OSC section, studies of second order corrections in this section are presented.

  14. Design, Testing and Modeling of the Direct Reactor Auxiliary Cooling System for FHRs

    Science.gov (United States)

    Lu, Qiuping

    Direct Reactor Auxiliary Cooling System (DRACS) is a passive decay heat removal system proposed for the Fluoride-salt-cooled High-temperature Reactor (FHR) that combines coated particle fuel and a graphite moderator with a liquid fluoride salt as the coolant. The DRACS features three coupled natural circulation/convection loops, relying completely on buoyancy as the driving force. These loops are coupled through two heat exchangers, namely, the DRACS Heat Exchanger (DHX) and the Natural Draft Heat Exchanger (NDHX). In addition, a fluidic diode is employed to minimize the parasitic flow into the DRACS primary loop and correspondingly the heat loss to the DRACS during normal operation of the reactor, but to keep the DRACS ready for activation, if needed, during accidents. While the DRACS concept has been proposed, there are no actual prototypic DRACS systems for FHRs built or tested in the literature. The primary goal of the present research is to design, test, and model the DRACS for FHR applications. Previously, a detailed modular design of the DRACS for a 20-MWth FHR was developed. As a starting point, the DRACS was designed to remove 1% of the reactor nominal power, i.e., 200 kW decay power. In addition, a detailed scaling analysis has been performed to develop the key non-dimensional numbers that characterize the DRACS system. Based on the previous work on the prototypic DRACS design and scaling analysis, two scaled-down test facilities have been designed and constructed, namely, Low-temperature DRACS Test Facility (LTDF) and High-temperature DRACS Test Facility (HTDF). The LTDF has a nominal power capacity of 6 kW. It uses 1.0-MPa water as the primary coolant, 0.1-MPa water as the secondary coolant, and ambient air as the ultimate heat sink. The main purpose of the LTDF is to examine the couplings among the three natural circulation/convection loops in the DRACS, as well as to provide design and operation experience for the HTDF. An extensive test matrix has

  15. Evaluation of the NightCool Nocturnal Radiation Cooling Concept: Annual Performance Assessment in Scale Test Buildings Stage Gate 1B

    Energy Technology Data Exchange (ETDEWEB)

    Parker, Danny S. [Florida Solar Energy Center, Cocoa, FL (United States); Sherwin, John R. [Florida Solar Energy Center, Cocoa, FL (United States)

    2008-03-01

    In this report, data is presented on the long-term comparative with all of NightCool system fully operational, with circulating fans when attic conditions are favorable for nocturnal cooling and with conventional air conditioning at other times. Data is included for a full year of the cooling season in Central Florida, which stretches from April to November of 2007.

  16. Electromagnetic analysis of the Korean helium cooled ceramic reflector test blanket module set

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Youngmin, E-mail: ymlee@nfri.re.kr [National Fusion Research Institute, Daejeon (Korea, Republic of); Ku, Duck Young [National Fusion Research Institute, Daejeon (Korea, Republic of); Lee, Dong Won [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Ahn, Mu-Young; Park, Yi-Hyun; Cho, Seungyon [National Fusion Research Institute, Daejeon (Korea, Republic of)

    2016-11-01

    Korean helium cooled ceramic reflector (HCCR) test blanket module set (TBM-set) will be installed at equatorial port #18 of Vacuum Vessel in ITER in order to test the breeding blanket performance for forthcoming fusion power plant. Since ITER tokamak has a set of electromagnetic coils (Central Solenoid, Poloidal Field and Toroidal Field coil set) around Vacuum Vessel, the HCCR TBM-set, the TBM and associated shield, is greatly influenced by magnetic field generated by these coils. In the case of fast transient electromagnetic events such as major disruption, vertical displacement event or magnet fast discharge, magnetic field and induced eddy current results in huge electromagnetic load, known as Lorentz load, on the HCCR TBM-set. In addition, the TBM-set experiences electromagnetic load due to magnetization of the structural material not only during the fast transient events but also during normal operation since the HCCR TBM adopts Reduced Activation Ferritic Martensitic (RAFM) steel as a structural material. This is known as Maxwell load which includes Lorentz load as well as load due to magnetization of structure material. This paper presents electromagnetic analysis results for the HCCR TBM-set. For analysis, a 20° sector finite model was constructed considering ITER configuration such as Vacuum Vessel, ITER shield blankets, Central Solenoid, Poloidal Field, Toroidal Field coil set as well as the HCCR TBM-set. Three major disruptions (operational event, likely event and highly unlikely event) were selected for analysis based on the load specifications. ANSYS-EMAG was used as a calculation tool. The results of EM analysis will be used as input data for the structural analysis.

  17. Microbial fouling community analysis of the cooling water system of a nuclear test reactor with emphasis on sulphate reducing bacteria.

    Science.gov (United States)

    Balamurugan, P; Joshi, M Hiren; Rao, T S

    2011-10-01

    Culture and molecular-based techniques were used to characterize bacterial diversity in the cooling water system of a fast breeder test reactor (FBTR). Techniques were selected for special emphasis on sulphate-reducing bacteria (SRB). Water samples from different locations of the FBTR cooling water system, in addition to biofilm scrapings from carbon steel coupons and a control SRB sample were characterized. Whole genome extraction of the water samples and SRB diversity by group specific primers were analysed using nested PCR and denaturing gradient gel electrophoresis (DGGE). The results of the bacterial assay in the cooling water showed that the total culturable bacteria (TCB) ranged from 10(3) to 10(5) cfu ml(-1); iron-reducing bacteria, 10(3) to 10(5) cfu ml(-1); iron oxidizing bacteria, 10(2) to 10(3) cfu ml(-1) and SRB, 2-29 cfu ml(-1). However, the counts of the various bacterial types in the biofilm sample were 2-3 orders of magnitude higher. SRB diversity by the nested PCR-DGGE approach showed the presence of groups 1, 5 and 6 in the FBTR cooling water system; however, groups 2, 3 and 4 were not detected. The study demonstrated that the PCR protocol influenced the results of the diversity analysis. The paper further discusses the microbiota of the cooling water system and its relevance in biofouling.

  18. A Reusable, Oxidizer-Cooled, Hybrid Aerospike Rocket Motor for Flight Test Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed innovation is to use the refrigerant capabilities of nitrous oxide (N2O) to provide the cooling required for reusable operation of an aerospike nozzle...

  19. Initial operation of a solar heating and cooling system in a full-scale solar building test facility

    Science.gov (United States)

    Knoll, R. H.; Miao, D.; Hamlet, I. L.; Jensen, R. N.

    1976-01-01

    The Solar Building Test Facility (SBTF) located at Hampton, Virginia became operational in early summer of 1976. This facility is a joint effort by NASA-Lewis and NASA-Langley to advance the technology for heating and cooling of office buildings with solar energy. Its purposes are to (1) test system components which include high-performing collectors, (2) test performance of complete solar heating and cooling system, (3) investigate component interactions and (4) investigate durability, maintenance and reliability of components. The SBTF consists of a 50,000 square foot office building modified to accept solar heated water for operation of an absorption air conditioner and for the baseboard heating system. A 12,666 square foot solar collector field with a 30,000 gallon storage tank provides the solar heated water. A description of the system and the collectors selected is given here, along with the objectives, test approach, expected system performance and some preliminary results.

  20. Application of Simulated Reactivity Feedback in Nonnuclear Testing of a Direct-Drive Gas-Cooled Reactor

    Science.gov (United States)

    Bragg-Sitton, S. M.; Webster, K. L.

    2007-01-01

    Nonnuclear testing can be a valuable tool in the development of an in-space nuclear power or propulsion system. In a nonnuclear test facility, electric heaters are used to simulate heat from nuclear fuel. Standard testing allows one to fully assess thermal, heat transfer, and stress related attributes of a given system but fails to demonstrate the dynamic response that would be present in an integrated, fueled reactor system. The integration of thermal hydraulic hardware tests with simulated neutronic response provides a bridge between electrically heated testing and full nuclear testing. By implementing a neutronic response model to simulate the dynamic response that would be expected in a fueled reactor system, one can better understand system integration issues, characterize integrated system response times and response and response characteristics, and assess potential design improvements with a relatively small fiscal investment. Initial system dynamic response testing was demonstrated on the integrated SAFE 100a heat pipe cooled, electrically heated reactor and heat exchanger hardware. This Technical Memorandum discusses the status of the planned dynamic test methodology for implementation in the direct-drive gas-cooled reactor testing and assesses the additional instrumentation needed to implement high-fidelity dynamic testing.

  1. Verification test results of a cutting technique for the ITER blanket cooling pipes

    Energy Technology Data Exchange (ETDEWEB)

    Shigematsu, Soichiro, E-mail: shigematsu.soichiro@jaea.go.jp [Japan Atomic Energy Agency, 801-1 Mukoyama, Naka, Ibaraki (Japan); Tanigawa, Hisashi; Aburadani, Atsushi; Takeda, Nobukazu; Kakudate, Satoshi [Japan Atomic Energy Agency, 801-1 Mukoyama, Naka, Ibaraki (Japan); Mori, Seiji; Nakahira, Masataka; Raffray, Rene; Merola, Mario [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France)

    2012-08-15

    For replacement of the first wall (FW) of the international thermonuclear experimental reactor (ITER), cutting and welding tools for the cooling pipes must be able to access a pipe from the surface side of the FW and cut/weld the pipe from the inside the cooling pipe (inner diameter: 42.72 mm, thickness: 2.77 mm). The cutting tool for the pipe end is required to cut a flat plate circularly from the surface side of the FW (cutting diameter: approximately 44 mm, plate thickness: 5 mm). To determine the specifications for both the tools and the blanket hydraulic connections, the ITER Organization (IO) and the Japan Domestic Agency (JADA) conducted research and development activities regarding the FW replacement. This paper describes the current status of the development of cutting tools for the cooling pipe connection.

  2. Colorado State University program for developing, testing, evaluating and optimizing solar heating and cooling systems

    Science.gov (United States)

    1993-01-01

    This program includes six tasks. The tasks are as follows: (1) a project measuring the performance of unique solar system components; (2) a project to develop a methodology for determining annual performance ratings of solar domestic hot water systems; (3) a project that will identify, analyze, design, build, and experimentally evaluate SDHW systems incorporating advanced concepts and components; (4) a liquid desiccant cooling system development project; (5) a project that will perform TRNSYS simulations to determine potential energy savings for desiccant cooling systems, especially in humid climates; and (6) a management task. The objectives and progress in each task are described.

  3. Analysis of the cool down related cavity performance of the European XFEL vertical acceptance tests

    CERN Document Server

    Wenskat, Marc

    2016-01-01

    It has been reported that the cool down dynamics across $T_c$ has a significant influence on the observed quality factors $Q_0$ of a cavity, which is most likely due to trapped flux. In this document we show the results of the investigation if such a correlation can be observed during the European XFEL cavity production.

  4. Topologically clustering: a method for discarding mismatches

    Science.gov (United States)

    Wang, Yongtao; Zhang, Dazhi; Gao, Chenqiang; Tian, Jinwen

    2007-11-01

    Wide baseline stereo correspondence has become a challenging and attractive problem in computer vision and its related applications. Getting high correct ratio initial matches is a very important step of general wide baseline stereo correspondence algorithm. Ferrari et al. suggested a voting scheme called topological filter in [3] to discard mismatches from initial matches, but they didn't give theoretical analysis of their method. Furthermore, the parameter of their scheme was uncertain. In this paper, we improved Ferraris' method based on our theoretical analysis, and presented a novel scheme called topologically clustering to discard mismatches. The proposed method has been tested using many famous wide baseline image pairs and the experimental results showed that the developed method can efficiently extract high correct ratio matches from low correct ratio initial matches for wide baseline image pairs.

  5. Testing a generalized cooling procedure in the complex Langevin simulation of chiral Random Matrix Theory

    CERN Document Server

    Nagata, Keitaro; Shimasaki, Shinji

    2015-01-01

    The complex Langevin method has been attracting much attention as a solution to the sign problem since the method was shown to work in finite density QCD in the deconfined phase by using the so-called gauge cooling procedure. Whether it works also in the confined phase with light quarks is still an open question, though. In order to shed light on this question, we apply the method to the chiral Random Matrix Theory, which describes the epsilon regime of finite density QCD. Earlier works reported that a naive implementation of the method fails to reproduce the known exact results and that the problem can be solved by choosing a suitable coordinate. In this work we stick to the naive implementation, and show that a generalized gauge cooling procedure can be used to avoid the problem.

  6. Application of Hot Strength and Ductility Test to Optimization of Secondary Cooling System in Billet Continuous Casting Process

    Institute of Scientific and Technical Information of China (English)

    WANG Biao; JI Zhen-ping; LIU Wen-hong; MA Jiao-cheng; XIE Zhi

    2008-01-01

    By means of Gleeble-1500 dynamic thermomechanical simulator,the continuous casting process for HRB335C steel was simulated using solidifying method and hot ductility and strength of the steel were determined.The test results indicate that there are three temperature regions of brittleness for HRB335C billet in the temperature range from 700℃ to solidification point;the first temperature region of brittleness is 1 300℃ to solidification point of the billet,the second temperature region of brittleness is 1 200-1 000℃,and the third temperature region of brittleness is 700-850℃;the steel is plastic at 850-1 000℃.The cracking sensitivity was studied in the different temperature zones of the brittleness for steel HRB335C and the target surface temperature curve for the secondary cooling is determined.With optimized process,the mathematical model of the steady temperature field with two-dimensional heat transfer for 150 mm×150 mm HRB335C steel billet was established to optimize the secondary cooling process.The conic relation of water distribution between secondary cooling water flux and casting speed is regressed.Keeping the surface temperature of billet before the straightening point above 1 000℃,the results of billet test indicate that there is free central shrinkage cavity.The billet defect is decreased greatly,and the quality of billet is obviously improved.

  7. Topical report : NSTF facilities plan for water-cooled VHTR RCCS : normal operational tests.

    Energy Technology Data Exchange (ETDEWEB)

    Farmer, M. T.; Kilsdonk, D. J.; Tzanos, C. P.; Lomperski, S.; Aeschlimann, R. W.; Nuclear Engineering Division

    2006-09-01

    As part of the Department of Energy (DOE) Generation IV roadmapping activity, the gas-cooled Very High Temperature Reactor (VHTR) has been selected as the principal concept for hydrogen production and other process-heat applications such as district heating and potable water production. On this basis, the DOE has selected the VHTR for additional R&D with the ultimate goal of demonstrating emission-free electricity and hydrogen production with this advanced reactor concept.

  8. Motion of flux transfer events: a test of the Cooling model

    Directory of Open Access Journals (Sweden)

    R. C. Fear

    2007-07-01

    Full Text Available The simple model of reconnected field line motion developed by Cooling et al. (2001 has been used in several recent case studies to explain the motion of flux transfer events across the magnetopause. We examine 213 FTEs observed by all four Cluster spacecraft under a variety of IMF conditions between November 2002 and June 2003, when the spacecraft tetrahedron separation was ~5000 km. Observed velocities were calculated from multi-spacecraft timing analysis, and compared with the velocities predicted by the Cooling model in order to check the validity of the model. After excluding three categories of FTEs (events with poorly defined velocities, a significant velocity component out of the magnetopause surface, or a scale size of less than 5000 km, we were left with a sample of 118 events. 78% of these events were consistent in both direction of motion and speed with one of the two model de Hoffmann-Teller (dHT velocities calculated from the Cooling model (to within 30° and a factor of two in the speed. We also examined the plasma signatures of several magnetosheath FTEs; the electron signatures confirm the hemisphere of connection indicated by the model in most cases. This indicates that although the model is a simple one, it is a useful tool for identifying the source regions of FTEs.

  9. Testing the cooling flow model in the intermediate polar EX Hydrae

    CERN Document Server

    Luna, G J M; Brickhouse, N S; Mauche, C W; Suleimanov, V; .,

    2015-01-01

    We use the best available X-ray data from the intermediate polar EX Hydrae to study the cooling-flow model often applied to interpret the X-ray spectra of these accreting magnetic white dwarf binaries. First, we resolve a long-standing discrepancy between the X-ray and optical determinations of the mass of the white dwarf in EX Hya by applying new models of the inner disk truncation radius. Our fits to the X-ray spectrum now agree with the white dwarf mass of 0.79 M$_{\\odot}$sun determined using dynamical methods through spectroscopic observations of the secondary. We use a simple isobaric cooling flow model to derive the emission line fluxes, emission measure distribution, and H-like to He-like line ratios for comparison with the 496 ks Chandra High Energy Transmission Grating observation of EX Hydrae. We find that the H/He ratios are not well reproduced by this simple isobaric cooling flow model and show that while H-like line fluxes can be accurately predicted, fluxes of lower-Z He-like lines are significa...

  10. Topical report: Natural convection shutdown heat removal test facility (NSTF) evaluation for generating additional reactor cavity cooling system (RCCS) data.

    Energy Technology Data Exchange (ETDEWEB)

    Farmer, M. T.; Kilsdonk, D. J.; Tzanos, C.P.; Lomperski, S.; Aeschlimann, R.W.; Pointer, D.; Nuclear Engineering Division

    2005-09-01

    As part of the Department of Energy (DOE) Generation IV roadmapping activity, the Very High Temperature gas cooled Reactor (VHTR) has been selected as the principal concept for hydrogen production and other process-heat applications such as district heating and potable water production. On this basis, the DOE has selected the VHTR for additional R&D with the ultimate goal of demonstrating emission-free electricity and hydrogen production with this advanced reactor concept. One of the key passive safety features of the VHTR is the potential for decay heat removal by natural circulation of air in a Reactor Cavity Cooling System (RCCS). The air-cooled RCCS concept is notably similar to the Reactor Vessel Auxiliary Cooling System (RVACS) that was developed for the General Electric PRISM sodium-cooled fast reactor. As part of the DOE R&D program that supported the development of this fast reactor concept, the Natural Convection Shutdown Heat Removal Test Facility (NSTF) was developed at ANL to provide proof-of-concept data for the RVACS under prototypic natural convection flow, temperature, and heat flux conditions. Due to the similarity between RVACS and the RCCS, current VHTR R&D plans call for the utilization of the NSTF to provide RCCS model development and validation data, in addition to supporting design validation and optimization activities. Both air-cooled and water-cooled RCCS designs are to be included. In support of this effort, ANL has been tasked with the development of an engineering plan for mechanical and instrumentation modifications to NSTF to ensure that sufficiently detailed temperature, heat flux, velocity and turbulence profiles are obtained to adequately qualify the codes under the expected range of air-cooled RCCS flow conditions. Next year, similar work will be carried out for the alternative option of a water-cooled RCCS design. Analysis activities carried out in support of this experiment planning task have shown that: (a) in the RCCS, strong

  11. Forced flow He vapor cooled critical current testing facility for measurements of superconductors in a wide temperature and magnetic field range

    Science.gov (United States)

    Baskys, Algirdas; Hopkins, Simon C.; Bader, Jakob; Glowacki, Bartek A.

    2016-10-01

    As superconducting materials find their way into applications, there is increasing need to verify their performance at operating conditions. Testing of critical current with respect to temperature and magnetic field is of particular importance. However, testing facilities covering a range of temperatures and magnetic fields can be costly, especially when considering the cooling power required in the cryogenic system in the temperature range below 65 K (inaccessible for LN2). Critical currents in excess of 500 A are common for commercial samples, making the testing of such samples difficult in setups cooled via a cryocooler, moreover it often does not represent the actual cooling conditions that the sample will experience in service. This work reports the design and operation of a low-cost critical current testing facility, capable of testing samples in a temperature range of 10-65 K, with magnetic field up to 1.6 T and measuring critical currents up to 900 A with variable cooling power.

  12. Performance of a 4 Kelvin pulse-tube cooled cryostat with dc SQUID amplifiers for bolometric detector testing

    CERN Document Server

    Barron, Darcy; Keating, Brian; Quillin, Ron; Stebor, Nathan; Wilson, Brandon

    2013-01-01

    The latest generation of cosmic microwave background (CMB) telescopes is searching for the undetected faint signature of gravitational waves from inflation in the polarized signal of the CMB. To achieve the unprecedented levels of sensitivity required, these experiments use arrays of superconducting Transition Edge Sensor (TES) bolometers that are cooled to sub-Kelvin temperatures for photon-noise limited performance. These TES detectors are read out using low- noise SQUID amplifiers. To rapidly test these detectors and similar devices in a laboratory setting, we constructed a cryogenic refrigeration chain consisting of a commercial two-stage pulse-tube cooler, with a base temperature of 3 K, and a closed-cycle 3He/4He/3He sorption cooler, with a base temperature of 220 mK. A commercial dc SQUID system, with sensors cooled to 4 K, was used as a highly-sensitive cryogenic ammeter. Due to the extreme sensitivity of SQUIDs to changing magnetic fields, there are several challenges involving cooling them with puls...

  13. Laboratory and Field Test of Movable Conduction-Cooled High-Temperature SMES for Power System Stability Enhancement

    DEFF Research Database (Denmark)

    Fang, Jiakun; Wen, J.; Wang, S.

    2013-01-01

    ’ effectiveness on improvements of system voltage stability and on the oscillation damping. Test results indicate that the SMES system has the features of fast response and four-quadrant power operation. The accessories for the movability of the SEMS system are well designed. The system is feasible to be used......This paper introduces the first movable conduction-cooled high temperature superconducting magnetic energy storage (SMES) system developed in China. The SMES is rated at 380 V / 35 kJ / 7 kW, consisting of the high temperature magnet confined in a dewar, the cryogenic unit, the converter...... in power systems....

  14. THE COMPONENT TEST FACILITY – A NATIONAL USER FACILITY FOR TESTING OF HIGH TEMPERATURE GAS-COOLED REACTOR (HTGR) COMPONENTS AND SYSTEMS

    Energy Technology Data Exchange (ETDEWEB)

    David S. Duncan; Vondell J. Balls; Stephanie L. Austad

    2008-09-01

    The Next Generation Nuclear Plant (NGNP) and other High-Temperature Gas-cooled Reactor (HTGR) Projects require research, development, design, construction, and operation of a nuclear plant intended for both high-efficiency electricity production and high-temperature industrial applications, including hydrogen production. During the life cycle stages of an HTGR, plant systems, structures and components (SSCs) will be developed to support this reactor technology. To mitigate technical, schedule, and project risk associated with development of these SSCs, a large-scale test facility is required to support design verification and qualification prior to operational implementation. As a full-scale helium test facility, the Component Test facility (CTF) will provide prototype testing and qualification of heat transfer system components (e.g., Intermediate Heat Exchanger, valves, hot gas ducts), reactor internals, and hydrogen generation processing. It will perform confirmation tests for large-scale effects, validate component performance requirements, perform transient effects tests, and provide production demonstration of hydrogen and other high-temperature applications. Sponsored wholly or in part by the U.S. Department of Energy, the CTF will support NGNP and will also act as a National User Facility to support worldwide development of High-Temperature Gas-cooled Reactor technologies.

  15. Design Report for the ½ Scale Air-Cooled RCCS Tests in the Natural convection Shutdown heat removal Test Facility (NSTF)

    Energy Technology Data Exchange (ETDEWEB)

    Lisowski, D. D. [Argonne National Lab. (ANL), Argonne, IL (United States); Farmer, M. T. [Argonne National Lab. (ANL), Argonne, IL (United States); Lomperski, S. [Argonne National Lab. (ANL), Argonne, IL (United States); Kilsdonk, D. J. [Argonne National Lab. (ANL), Argonne, IL (United States); Bremer, N. [Argonne National Lab. (ANL), Argonne, IL (United States); Aeschlimann, R. W. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2014-06-01

    The Natural convection Shutdown heat removal Test Facility (NSTF) is a large scale thermal hydraulics test facility that has been built at Argonne National Laboratory (ANL). The facility was constructed in order to carry out highly instrumented experiments that can be used to validate the performance of passive safety systems for advanced reactor designs. The facility has principally been designed for testing of Reactor Cavity Cooling System (RCCS) concepts that rely on natural convection cooling for either air or water-based systems. Standing 25-m in height, the facility is able to supply up to 220 kW at 21 kW/m2 to accurately simulate the heat fluxes at the walls of a reactor pressure vessel. A suite of nearly 400 data acquisition channels, including a sophisticated fiber optic system for high density temperature measurements, guides test operations and provides data to support scaling analysis and modeling efforts. Measurements of system mass flow rate, air and surface temperatures, heat flux, humidity, and pressure differentials, among others; are part of this total generated data set. The following report provides an introduction to the top level-objectives of the program related to passively safe decay heat removal, a detailed description of the engineering specifications, design features, and dimensions of the test facility at Argonne. Specifications of the sensors and their placement on the test facility will be provided, along with a complete channel listing of the data acquisition system.

  16. The ITER neutral beam test facility: designs of the general infrastructure, cryo-system and cooling plant

    Energy Technology Data Exchange (ETDEWEB)

    Cordier, J.J.; Hemsworth, R.; Chantant, M.; Gravil, B.; Henry, D.; Sabathier, F.; Doceul, L.; Thomas, E.; Van Houtte, D. [Association Euratom-CEA Cadarache (DSM/DRFC), 13 - Saint-Paul-lez-Durance (France). Dept. de Recherches sur la Fusion Controlee; Zaccaria, P.; Antoni, V.; Dal Bello, S.; Masiello, A.; Marcuzzi, D. [Consorzio RFX Association Euratom-ENEA, Padova (Italy); Antipenkov, A.; Dremel, M.; Day, C. [Institut fur Technische Physik, FZK, Karlsruhe (Germany); Mondino, P.L. [Max-Planck-Institut fuer Plasmaphysik, EFDA CSU, Garching (Germany)

    2004-07-01

    The CEA Association is involved, in close collaboration with ENEA, FZK, IPP and UKEA European Associations, in the first ITER neutral beam injector and the ITER neutral beam test facility design (NBTF). A total power of about 50 MW will have to be removed in steady state on the neutral beam test facility (NBTF). The main purpose of this task is to make progress with the detailed design of the first ITER NB injector and to start the conceptual design of the ITER NBTF. The general infrastructure layout of a generic site for the NBTF, includes the test facility itself equipped of a dedicated beamline vessel and integration studies of associated auxiliaries as cooling plant, cryo-plant and fore-pumping system. The general infrastructure and auxiliaries layout of the NBTF are described. (authors)

  17. The design of multi-megawatt actively cooled beam dumps for the Neutral-Beam Engineering Test Facility

    Science.gov (United States)

    Paterson, J. A.; Koehler, G.; Wells, R. P.

    1981-10-01

    To test neutral beam sources up to 170 keV, 65 Amps, with 30 second beam on times, actively cooled beam dumps for both the neutral and ionized particles are required. The dumps should be able to dissipate a wide range of power density profiles by utilizing a standard modular panel design which is incorporated into a moveable support structure. The thermal hydraulic design of the panels permit the dissipation of 2 kW/sq cm anywhere on the panel surface. The water requirements of the dumps are optimized by restricting the flow to panel sections where the heat flux falls short of the design value. The mechanical design of the beam-dump structures is described along with tests performed on two different panel designs. The dissipation capabilities of the panels were tested at the critical regions to verify their use in the beam dump assemblies.

  18. Activation analyses for the Korea helium cooled ceramic reflector test blanket module

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Cheol Woo, E-mail: cwl@kaeri.re.kr [Korea Atomic Energy Research Institute, 989 Daeduck-daero, Yuseong-gu, Daejeon 305-353 (Korea, Republic of); Lee, Young-Ouk [Korea Atomic Energy Research Institute, 989 Daeduck-daero, Yuseong-gu, Daejeon 305-353 (Korea, Republic of); Ahn, Mu-Young; Cho, Seungyon [National Fusion Research Institute, Gwahangno, Yuseong-gu, Daejeon 305-333 (Korea, Republic of); Lee, Dong Won [Korea Atomic Energy Research Institute, 989 Daeduck-daero, Yuseong-gu, Daejeon 305-353 (Korea, Republic of)

    2013-10-15

    The activation analyses were performed to obtain activities, inventories and dose rates after shutdown for the Korea HCCR TBM. MonteBurns code coupled with MCNP and CINDER codes was used in the activation calculation and the irradiation history based on the SA2 scenario was applied. The total activity in TBM after shutdown was evaluated as a value of 4.12 × 10{sup 16} Bq. Dose rates after shutdown from the activated HCCR TBM was estimated. The decay gamma-ray spectra in each region inside TBM were estimated based on the calculated activities. The dose rate at 0 cm–3 m from the FW surface of HCCR TBM was evaluated according to the cooling time of 1 day, 1 week, 1 month, 6 months and 1 year. The dose rate at 0 cm from the FW surface was evaluated to be 575.84 Sv/h at 1 day after shutdown.

  19. The development of test software for the inadequate core cooling monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Soon Sung

    1996-06-01

    The test software including the ICCMS simulator which is necessary for dynamic test for the ICCMS software in PWR is developed. The developed dynamic test software consists of the module test simulator, the integration test simulator, and the test result analyser. The simulator was programmed by C language according to the same algorithm requirements for the FORTRAN version ICCMS software, and also for the Factory Acceptance Test (FAT). And the simulator can be used as training tool for the reactor operator and system development tool for the performance improvement. (author). 4 tabs., 8 figs., 11 refs.

  20. Irradiation Test Plan of the Dual Cooled UO{sub 2} Annular Pellets

    Energy Technology Data Exchange (ETDEWEB)

    Bang, Je Geon; Kim, Dae Ho; Chun, Tae Hyun; Kim, Keon Sik; Kim, Hyung Kyu; In, Wang Ki; Yang, Yong Sik; Song, Kun Woo; Chae, Hee Taek; Seo, Chul Gyo

    2008-09-15

    In order to study the behavior of the UO{sub 2} annular pellet developed by the high performance fuel technology development project, irradiation test will be carried out in HANARO research reactor for 5 cycles up to the burnup 12 MWD/kgU. After irradiation test in HANARO, the test fuel rod will be transferred to the hot cell and examined to verify the in-pile behavior. For the irradiation test, new irradiation test rig was designed and manufactured. The out-pile verification test and safety evaluation were performed and the results showed that the test rig and test rod will maintain the integrity and satisfy all the safety requirements during irradiation test. Therefore, it is expected that UO{sub 2} annular fuel can be irradiated safely in HANARO.

  1. Biofouling characteristics and identification of preponderant bacteria at different nutrient levels in batch tests of a recirculating cooling water system.

    Science.gov (United States)

    Liu, Fang; Zhao, Chao-Cheng; Xia, Lu; Yang, Fei; Chang, Xin; Wang, Yong-Qiang

    2011-01-01

    Understanding the influence of nutrient levels on biofouling control is an important requirement for management strategies in a recirculating cooling water system. Nutrient limitation may be one way to control biofouling development without increasing biocide dosing. Therefore, this study was carried out to investigate the effects of nutrient levels on biofouling characteristics and to identify the preponderant bacteria in the batch tests with a simulated cooling water system. The biofouling characteristics were assessed by varying the biofoulant mass and the bacteria respiratory activity, which was estimated by measuring oxygen uptake rates. According to the results obtained in nutrient factor experiments, the biofouling could be better controlled at carbon, nitrogen and phosphorus concentrations of 30 mg N/L, 8 mg N/L and 1.0 mg P/L, respectively. Increasing carbon concentrations shortened the biofouling initial growth period and resulted in higher biofoulant mass. The preponderant bacteria strains involved in biofouling under two culture conditions were identified by applying both physiological and biochemical tests and further molecular biology techniques with phylogenetic affiliation analysis. Enterobacter (family Enterobacteriaceae), Staphylococcus (family Micrococcaceae), Bacillus (family Bacillaceae), Proteus (family Enterobacteriaceae), Neisseria (family Neisseriaceae) and Pseudomonas (family Pseudomonadaceae) were dominant in the conditions of lower carbon concentration (30 mg/L). Enterobacter are autotrophs, but the other five bacteria are all heterotrophs. In the conditions of higher carbon concentration (70 mg/L), Klebsiella (family Enterobacteriaceae), Enterobacter and Microbacterium (family Microbacteriaceae) were dominant; Enterobacter and Microbacterium are heterotrophs.

  2. Multi-Phase Methane Heat Transfer Testing/Modeling for Regenerative Cooling Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This proposal will complete testing of existing straight channel test articles with enhanced instrumentation.  Analytical work will focus on upgrades to the...

  3. Influence of framework design, contraction mismatch, and thermal history on porcelain checking in fixed partial dentures.

    Science.gov (United States)

    Anusavice, K J; Gray, A E

    1989-01-01

    The objective of this study was to characterize the relative influence of contraction mismatch, framework design, furnace type, cooling rate, and multiple firings on immediate or delayed checking in fixed partial dentures. Frameworks for 60 anterior bridges (three-unit fixed partial dentures) were cast from a low-expansion Au-Pd alloy (O) and a high-expansion Pd-Ag alloy (J). A high-expansion porcelain (B) was applied to each of three framework designs. Firing was performed at heating rates of 56 degrees C/min and 180 degrees C/min. Specimens were cooled at two rates after each of five glazing cycles. For O-B specimens which exhibited a negative thermal contraction mismatch between 600 degrees C and 25 degrees C, 60% of the bridge specimens failed when they were subjected to slow cooling preceded by either fast or slow heating. When J-B specimens (which exhibited a smaller negative contraction mismatch) were heated and cooled rapidly, no failures occurred through all of the firing cycles. However, cracks were observed in 13.3% of the J-B bridges which were slowly heated and rapidly cooled. Delayed cracks (after the fifth glaze cycle) developed over periods of up to two years only in bridges which were slowly cooled in the furnace chamber. The results of this study suggest that checking in conventional feldspathic porcelains can be promoted by slow cooling rates and an excessive number of firing cycles.

  4. A feasibility and optimization study to determine cooling time and burnup of advanced test reactor fuels using a nondestructive technique

    Energy Technology Data Exchange (ETDEWEB)

    Navarro, Jorge [Univ. of Utah, Salt Lake City, UT (United States)

    2013-12-01

    The goal of this study presented is to determine the best available non-destructive technique necessary to collect validation data as well as to determine burn-up and cooling time of the fuel elements onsite at the Advanced Test Reactor (ATR) canal. This study makes a recommendation of the viability of implementing a permanent fuel scanning system at the ATR canal and leads3 to the full design of a permanent fuel scan system. The study consisted at first in determining if it was possible and which equipment was necessary to collect useful spectra from ATR fuel elements at the canal adjacent to the reactor. Once it was establish that useful spectra can be obtained at the ATR canal the next step was to determine which detector and which configuration was better suited to predict burnup and cooling time of fuel elements non-destructively. Three different detectors of High Purity Germanium (HPGe), Lanthanum Bromide (LaBr3), and High Pressure Xenon (HPXe) in two system configurations of above and below the water pool were used during the study. The data collected and analyzed was used to create burnup and cooling time calibration prediction curves for ATR fuel. The next stage of the study was to determine which of the three detectors tested was better suited for the permanent system. From spectra taken and the calibration curves obtained, it was determined that although the HPGe detector yielded better results, a detector that could better withstand the harsh environment of the ATR canal was needed. The in-situ nature of the measurements required a rugged fuel scanning system, low in maintenance and easy to control system. Based on the ATR canal feasibility measurements and calibration results it was determined that the LaBr3 detector was the best alternative for canal in-situ measurements; however in order to enhance the quality of the spectra collected using this scintillator a deconvolution method was developed. Following the development of the deconvolution method

  5. On String Matching with Mismatches

    Directory of Open Access Journals (Sweden)

    Marius Nicolae

    2015-05-01

    Full Text Available In this paper, we consider several variants of the pattern matching with mismatches problem. In particular, given a text \\(T=t_1 t_2\\cdots t_n\\ and a pattern \\(P=p_1p_2\\cdots p_m\\, we investigate the following problems: (1 pattern matching with mismatches: for every \\(i, 1\\leq i \\leq n-m+1\\ output, the distance between \\(P\\ and \\(t_i t_{i+1}\\cdots t_{i+m-1}\\; and (2 pattern matching with \\(k\\ mismatches: output those positions \\(i\\ where the distance between \\(P\\ and \\(t_i t_{i+1}\\cdots t_{i+m-1}\\ is less than a given threshold \\(k\\. The distance metric used is the Hamming distance. We present some novel algorithms and techniques for solving these problems. We offer deterministic, randomized and approximation algorithms. We consider variants of these problems where there could be wild cards in either the text or the pattern or both. We also present an experimental evaluation of these algorithms. The source code is available at http://www.engr.uconn.edu/\\(\\sim\\man09004/kmis.zip.

  6. The thermal mismatch hypothesis explains host susceptibility to an emerging infectious disease.

    Science.gov (United States)

    Cohen, Jeremy M; Venesky, Matthew D; Sauer, Erin L; Civitello, David J; McMahon, Taegan A; Roznik, Elizabeth A; Rohr, Jason R

    2017-02-01

    Parasites typically have broader thermal limits than hosts, so large performance gaps between pathogens and their cold- and warm-adapted hosts should occur at relatively warm and cold temperatures, respectively. We tested this thermal mismatch hypothesis by quantifying the temperature-dependent susceptibility of cold- and warm-adapted amphibian species to the fungal pathogen Batrachochytrium dendrobatidis (Bd) using laboratory experiments and field prevalence estimates from 15 410 individuals in 598 populations. In both the laboratory and field, we found that the greatest susceptibility of cold- and warm-adapted hosts occurred at relatively warm and cool temperatures, respectively, providing support for the thermal mismatch hypothesis. Our results suggest that as climate change shifts hosts away from their optimal temperatures, the probability of increased host susceptibility to infectious disease might increase, but the effect will depend on the host species and the direction of the climate shift. Our findings help explain the tremendous variation in species responses to Bd across climates and spatial, temporal and species-level variation in disease outbreaks associated with extreme weather events that are becoming more common with climate change.

  7. DESIGN CHARACTERISTICS OF THE IDAHO NATIONAL LABORATORY HIGH-TEMPERATURE GAS-COOLED TEST REACTOR

    Energy Technology Data Exchange (ETDEWEB)

    Sterbentz, James; Bayless, Paul; Strydom, Gerhard; Kumar, Akansha; Gougar, Hans

    2016-11-01

    Uncertainty and sensitivity analysis is an indispensable element of any substantial attempt in reactor simulation validation. The quantification of uncertainties in nuclear engineering has grown more important and the IAEA Coordinated Research Program (CRP) on High-Temperature Gas Cooled Reactor (HTGR) initiated in 2012 aims to investigate the various uncertainty quantification methodologies for this type of reactors. The first phase of the CRP is dedicated to the estimation of cell and lattice model uncertainties due to the neutron cross sections co-variances. Phase II is oriented towards the investigation of propagated uncertainties from the lattice to the coupled neutronics/thermal hydraulics core calculations. Nominal results for the prismatic single block (Ex.I-2a) and super cell models (Ex.I-2c) have been obtained using the SCALE 6.1.3 two-dimensional lattice code NEWT coupled to the TRITON sequence for cross section generation. In this work, the TRITON/NEWT-flux-weighted cross sections obtained for Ex.I-2a and various models of Ex.I-2c is utilized to perform a sensitivity analysis of the MHTGR-350 core power densities and eigenvalues. The core solutions are obtained with the INL coupled code PHISICS/RELAP5-3D, utilizing a fixed-temperature feedback for Ex. II-1a.. It is observed that the core power density does not vary significantly in shape, but the magnitude of these variations increases as the moderator-to-fuel ratio increases in the super cell lattice models.

  8. Implementation of a Peltier-based cooling device for localized deep cortical deactivation during in vivo object recognition testing

    Science.gov (United States)

    Marra, Kyle; Graham, Brett; Carouso, Samantha; Cox, David

    2012-02-01

    While the application of local cortical cooling has recently become a focus of neurological research, extended localized deactivation deep within brain structures is still unexplored. Using a wirelessly controlled thermoelectric (Peltier) device and water-based heat sink, we have achieved inactivating temperatures (8 mm) than previously reported. After implanting the device into Long Evans rats' basolateral amygdala (BLA), an inhibitory brain center that controls anxiety and fear, we ran an open field test during which anxiety-driven behavioral tendencies were observed to decrease during cooling, thus confirming the device's effect on behavior. Our device will next be implanted in the rats' temporal association cortex (TeA) and recordings from our signal-tracing multichannel microelectrodes will measure and compare activated and deactivated neuronal activity so as to isolate and study the TeA signals responsible for object recognition. Having already achieved a top performing computational face-recognition system, the lab will utilize this TeA activity data to generalize its computational efforts of face recognition to achieve general object recognition.

  9. Testing the Large-Scale Environments of Cool-core and Noncool-core Clusters with Clustering Bias

    CERN Document Server

    Medezinski, Elinor; Coupon, Jean; Cen, Renyue; Gaspari, Massimo; Strauss, Michael A; Spergel, David N

    2016-01-01

    There is a well observed bimodality in X-ray astronomy between cool-core (CC) and non-cool-core (NCC) clusters, but the origin of this distinction is still largely unknown. Competing theories can be divided into internal (inside-out), in which internal physical processes transform or maintain the NCC phase, and external (outside-in), in which the cluster type is determined by its initial conditions, which in turn lead to different formation histories (i.e., assembly bias). We propose a new method that uses the relative assembly bias of CC to NCC clusters, as determined via the two-point cluster-galaxy cross-correlation function (CCF), to test whether formation history plays a role in determining their nature. We apply our method to 48 ACCEPT clusters, which have well resolved central entropies, and cross-correlate with the SDSS-III/BOSS LOWZ galaxy catalog. We find that the relative bias of NCC over CC clusters is $b = 1.42 \\pm 0.35$ ($1.6\\sigma$ different from unity). Our measurement is limited by the small ...

  10. Preliminary structural design and thermo-mechanical analysis of helium cooled solid breeder blanket for Chinese Fusion Engineering Test Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Li, Min; Chen, Hongli, E-mail: hlchen1@ustc.edu.cn; Zhou, Guangming; Liu, Qianwen; Wang, Shuai; Lv, Zhongliang; Ye, Minyou

    2015-02-15

    Highlights: • A helium cooled solid breeder blanket module was designed for CFETR. • Multilayer U-shaped pebble beds were adopted in the blanket module. • Thermal and thermo-mechanical analyses were carried out under normal operating conditions. • The analysis results were found to be acceptable. - Abstract: With the aim to bridge the R&D gap between ITER and fusion power plant, the Chinese Fusion Engineering Test Reactor (CFETR) was proposed to be built in China. The mission of CFETR is to address the essential R&D issues for achieving practical fusion energy. Its blanket is required to be tritium self-sufficient. In this paper, a helium cooled solid breeder blanket adopting multilayer U-shaped pebble beds was designed and analyzed. Thermo-mechanical analysis of the first wall and side wall combined with breeder unit was carried out for normal operating steady state conditions. The results showed that the maximum temperatures of the structural material, neutron multiplier and tritium breeder pebble beds are 523 °C, 558 °C and 787 °C, respectively, which are below the corresponding limits of 550 °C, 650 °C and 920 °C. The maximum equivalent stress of the structure is under the allowable value with a margin about 14.5%.

  11. Acceleration Test Method for Failure Prediction of the End Cap Contact Region of Sodium Cooled Fast Reactor Fuel Rod

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyung-Kyu; Lee, Young-Ho; Lee, Hyun-Seung; Lee, Kang-Hee [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2017-05-15

    This paper reports the results of an acceleration test to predict the contact-induced failure that could occur at the cylinder-to-hole joint for the fuel rod of a sodium-cooled fast reactor (SFR). To incorporate the fuel life of the SFR currently under development at KAERI (around 35,000 h), the acceleration test method of reliability engineering was adopted in this work. A finite element method was used to evaluate the flow-induced vibration frequency and amplitude for the test parameter values. Five specimens were tested. The failure criterion during the life of the SFR fuel was applied. The S-N curve of the HT-9, the material of concern, was used to obtain the acceleration factor. As a result, a test time of 16.5 h was obtained for each specimen. It was concluded that the B{sub 0.004} life would be guaranteed for the SFR fuel rods with 99% confidence if no failure was observed at any of the contact surfaces of the five specimens.

  12. The Hydraulic Test Report for Non-instrumented Irradiation Test Rig of DUO-Cooled Annular Pellet

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dae Ho; Lee, Kang Hee; Shin, Chang Hwan; Yang, Yong Sik; Kim, Sun Ki; Bang, Je Geon; Song, Kun Woo

    2007-08-15

    This report presents the results of pressure drop test and vibration test for non-instrumented rig of Advanced PWR DUO-Fuel Annular Pellet which were designed and fabricated by KAERI. From the pressure drop test results, it is noted that the flow velocity across the non-instrumented rig of Advanced PWR DUO-Fuel Annular Pellet corresponding to the pressure drop of 200 kPa is measured to be about 8.30 kg/sec. Vibration frequency results for the non-instrumented rig at the pump spin frequency ranges from 19.0 to 32.0 Hz, RMS(Root Mean Square) displacement for the non-instrumented rig of Advanced PWR DUO-Fuel Annular Pellet is less than 7.25 m, and the maximum displacement is less than 31.27 {mu}m. This test was performed at the FIVPET facility.

  13. Simulated growth of layers on a substrate with mismatch: structural studies

    Science.gov (United States)

    Tan, S.; Ghazali, A.; Lévy, J. C. S.

    1996-12-01

    High temperature deposition of metallic materials on a (111) face of a fcc substrate, followed by a slow cooling down to a given temperature, is simulated by means of a Monte-Carlo algorithm with Lennard-Jones interatomic pair potentials. Adsorption and growth modes on the surface are studied in order to determine whether the growth is three- or two-dimensional, according to relevant parameters such as lattice mismatch and relative atomic binding energy. For a ± 10% mismatch it is found that the Stranski-Krastanov process starts early and is later healed by the appearance of bridges between islands, after a deposition of about ten monolayers. The interlayer distance undergoes oscillations as a function of the layer number. This is observed for a ± 10% mismatch as well as for a 5% mismatch.

  14. Standard Practices for Simulated Service Testing for Corrosion of Metallic Containment Materials for Use With Heat-Transfer Fluids in Solar Heating and Cooling Systems

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1980-01-01

    1.1 These practices cover test procedures simulating field service for evaluating the performance under corrosive conditions of metallic containment materials in solar heating and cooling systems. All test results relate to the performance of the metallic containment material only as a part of a metal/fluid pair. Performance in these test procedures, taken by itself, does not necessarily constitute an adequate basis for acceptance or rejection of a particular metal/fluid pair in solar heating and cooling systems, either in general or in a particular design. 1.2 These practices describe test procedures used to evaluate the resistance to deterioration of metallic containment materials in the several conditions that may occur in operation of solar heating and cooling systems. These conditions include: (1) operating full flow; (2) stagnant empty vented; (3) stagnant, closed to atmosphere, non-draindown; and (4) stagnant, closed to atmosphere, draindown. 1.3 The recommended practices cover the following three te...

  15. Direct Mismatch Characterization of femto-Farad Capacitors

    KAUST Repository

    Omran, Hesham

    2015-08-17

    Reducing the capacitance of programmable capacitor arrays, commonly used in analog integrated circuits, is necessary for low-energy applications. However, limited mismatch data is available for small capacitors. We report mismatch measurement for a 2fF poly-insulator-poly (PIP) capacitor, which is the smallest reported PIP capacitor to the best of the authors’ knowledge. Instead of using complicated custom onchip circuitry, direct mismatch measurement is demonstrated and verified using Monte Carlo Simulations and experimental measurements. Capacitive test structures composed of 9 bit programmable capacitor arrays (PCAs) are implemented in a low-cost 0:35m CMOS process. Measured data is compared to mismatch of large PIP capacitors, theoretical models, and recently published data. Measurement results indicate an estimated average relative standard deviation of 0.43% for the 2fF unit capacitor, which is better than the reported mismatch of metal-oxide-metal (MOM) fringing capacitors implemented in an advanced 32nm CMOS process.

  16. Integral and Separate Effects Tests for Thermal Hydraulics Code Validation for Liquid-Salt Cooled Nuclear Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Peterson, Per

    2012-10-30

    The objective of the 3-year project was to collect integral effects test (IET) data to validate the RELAP5-3D code and other thermal hydraulics codes for use in predicting the transient thermal hydraulics response of liquid salt cooled reactor systems, including integral transient response for forced and natural circulation operation. The reference system for the project is a modular, 900-MWth Pebble Bed Advanced High Temperature Reactor (PB-AHTR), a specific type of Fluoride salt-cooled High temperature Reactor (FHR). Two experimental facilities were developed for thermal-hydraulic integral effects tests (IETs) and separate effects tests (SETs). The facilities use simulant fluids for the liquid fluoride salts, with very little distortion to the heat transfer and fluid dynamics behavior. The CIET Test Bay facility was designed, built, and operated. IET data for steady state and transient natural circulation was collected. SET data for convective heat transfer in pebble beds and straight channel geometries was collected. The facility continues to be operational and will be used for future experiments, and for component development. The CIET 2 facility is larger in scope, and its construction and operation has a longer timeline than the duration of this grant. The design for the CIET 2 facility has drawn heavily on the experience and data collected on the CIET Test Bay, and it was completed in parallel with operation of the CIET Test Bay. CIET 2 will demonstrate start-up and shut-down transients and control logic, in addition to LOFC and LOHS transients, and buoyant shut down rod operation during transients. Design of the CIET 2 Facility is complete, and engineering drawings have been submitted to an external vendor for outsourced quality controlled construction. CIET 2 construction and operation continue under another NEUP grant. IET data from both CIET facilities is to be used for validation of system codes used for FHR modeling, such as RELAP5-3D. A set of

  17. Stability test of conduction-cooled LTS/HTS composite coil

    Science.gov (United States)

    Cui, Ying Min; Wang, Yin Shun; Lv, Gang; Pi, Wei

    2016-06-01

    A small LTS/HTS composite coil made of NbTi/Cu and YBCO, with an inner diameter of 80 mm, an outer diameter of 88mm, a height of 50 mm, and an inductance of 5.5 μH, was designed to test its heat disturbance performance in a GM cryocooler. For comparison, a conventional LTS coil of a similar size made of NbTi/Cu wire was also tested. Transport current was applied from 50 A to 700 A at 8 K and 8.5 K, respectively. The two coils’ heat disturbance, minimum quench energy and quench propagation velocity performance were investigated and simulated. The results indicate that the LTS/HTS composite coil shows better thermal stability and is more fit for operation in conductive cryocooler systems compared to LTS coils.

  18. Clinicopathologic factors identify sporadic mismatch repair-defective colon cancers

    DEFF Research Database (Denmark)

    Halvarsson, Britta; Anderson, Harald; Domanska, Katarina;

    2008-01-01

    Identification of sporadic mismatch repair (MMR)-defective colon cancers is increasingly demanded for decisions on adjuvant therapies. We evaluated clinicopathologic factors for the identification of these prognostically favorable tumors. Histopathologic features in 238 consecutive colon cancers...... and excluded 61.5% of the tumors from MMR testing. This clinicopathologic index thus successfully selects MMR-defective colon cancers. Udgivelsesdato: 2008-Feb...

  19. On0Line Fuel Failure Monitor for Fuel Testing and Monitoring of Gas Cooled Very High Temperature Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Ayman I. Hawari; Mohamed A. Bourham

    2010-04-22

    IVery High Temperature Reactors (VHTR) utilize the TRISO microsphere as the fundamental fuel unit in the core. The TRISO microsphere (~ 1- mm diameter) is composed of a UO2 kernel surrounded by a porous pyrolytic graphite buffer, an inner pyrolytic graphite layer, a silicon carbide (SiC) coating, and an outer pyrolytic graphite layer. The U-235 enrichment of the fuel is expected to range from 4% – 10% (higher enrichments are also being considered). The layer/coating system that surrounds the UO2 kernel acts as the containment and main barrier against the environmental release of radioactivity. To understand better the behavior of this fuel under in-core conditions (e.g., high temperature, intense fast neutron flux, etc.), the US Department of Energy (DOE) is launching a fuel testing program that will take place at the Advanced Test Reactor (ATR) located at Idaho National Laboratory (INL). During this project North Carolina State University (NCSU) researchers will collaborate with INL staff for establishing an optimized system for fuel monitoring for the ATR tests. In addition, it is expected that the developed system and methods will be of general use for fuel failure monitoring in gas cooled VHTRs.

  20. Improvement of non destructive infrared test bed SATIR for examination of actively cooled tungsten armour Plasma Facing Components

    Energy Technology Data Exchange (ETDEWEB)

    Vignal, N., E-mail: nicolas.vignal@cea.fr; Desgranges, C.; Cantone, V.; Richou, M.; Courtois, X.; Missirlian, M.; Magaud, Ph.

    2013-10-15

    Highlights: • Non destructive infrared techniques for control ITER like PFCs. • Reflective surface such as W induce a measurement temperature error. • Numerical data processing by evaluation of the local emissivity. • SATIR test bed can control metallic surface with low and variable emissivity. -- Abstract: For steady state (magnetic) thermonuclear fusion devices which need large power exhaust capability and have to withstand heat fluxes in the range 10–20 MW m{sup −2}, advanced Plasma Facing Components (PFCs) have been developed. The importance of PFCs for operating tokamaks requests to verify their manufacturing quality before mounting. SATIR is an IR test bed validated and recognized as a reliable and suitable tool to detect cooling defaults on PFCs with CFC armour material. Current tokamak developments implement metallic armour materials for first wall and divertor; their low emissivity causes several difficulties for infrared thermography control. We present SATIR infrared thermography test bed improvements for W monoblocks components without defect and with calibrated defects. These results are compared to ultrasonic inspection. This study demonstrates that SATIR method is fully usable for PFCs with low emissivity armour material.

  1. Pilot-plant testing of magnetic filters for the N-Reactor primary cooling circuit

    Energy Technology Data Exchange (ETDEWEB)

    Emory, B.B.

    1982-01-01

    Data obtained during the laboratory loop test program using the high power HGMF indicates that removal efficiency for /sup 60/Co and subsequently the bulk of the crud, will be greater than 90% at field strength above .1 Tesla for the expanded metal mesh matrix. However, since /sup 54/Mn seems to exhibit paramagnetic behavior and the possibility of quantities of alpha iron forming during reactor shut down from oxygen inleakage, a field strength of .5 to 1 Tesla may be more appropriate for a full scale on-reactor installation. Crud loading of 50 gm per kg of matrix weight are readily obtainable and up to twice that amount has been reached.

  2. Experimental investigations of flow distribution in coolant system of Helium-Cooled-Pebble-Bed Test Blanket Module

    Energy Technology Data Exchange (ETDEWEB)

    Ilić, M.; Schlindwein, G., E-mail: georg.schlindwein@kit.edu; Meyder, R.; Kuhn, T.; Albrecht, O.; Zinn, K.

    2016-02-15

    Highlights: • Experimental investigations of flow distribution in HCPB TBM are presented. • Flow rates in channels close to the first wall are lower than nominal ones. • Flow distribution in central chambers of manifold 2 is close to the nominal one. • Flow distribution in the whole manifold 3 agrees well with the nominal one. - Abstract: This paper deals with investigations of flow distribution in the coolant system of the Helium-Cooled-Pebble-Bed Test Blanket Module (HCPB TBM) for ITER. The investigations have been performed by manufacturing and testing of an experimental facility named GRICAMAN. The facility involves the upper poloidal half of HCPB TBM bounded at outlets of the first wall channels, at outlet of by-pass pipe and at outlets of cooling channels in breeding units. In this way, the focus is placed on the flow distribution in two mid manifolds of the 4-manifold system: (i) manifold 2 to which outlets of the first wall channels and inlet of by-pass pipe are attached and (ii) manifold 3 which supplies channels in breeding units with helium coolant. These two manifolds are connected with cooling channels in vertical/horizontal grids and caps. The experimental facility has been built keeping the internal structure of manifold 2 and manifold 3 exactly as designed in HCPB TBM. The cooling channels in stiffening grids, caps and breeding units are substituted by so-called equivalent channels which provide the same hydraulic resistance and inlet/outlet conditions, but have significantly simpler geometry than the real channels. Using the conditions of flow similarity, the air pressurized at 0.3 MPa and at ambient temperature has been used as working fluid instead of HCPB TBM helium coolant at 8 MPa and an average temperature of 370 °C. The flow distribution has been determined by flow rate measurements at each of 28 equivalent channels, while the pressure distribution has been obtained measuring differential pressure at more than 250 positions. The

  3. Electron cooling

    Science.gov (United States)

    Meshkov, I.; Sidorin, A.

    2004-10-01

    The brief review of the most significant and interesting achievements in electron cooling method, which took place during last two years, is presented. The description of the electron cooling facilities-storage rings and traps being in operation or under development-is given. The applications of the electron cooling method are considered. The following modern fields of the method development are discussed: crystalline beam formation, expansion into middle and high energy electron cooling (the Fermilab Recycler Electron Cooler, the BNL cooler-recuperator, cooling with circulating electron beam, the GSI project), electron cooling in traps, antihydrogen generation, electron cooling of positrons (the LEPTA project).

  4. Stochastic Cooling

    Energy Technology Data Exchange (ETDEWEB)

    Blaskiewicz, M.

    2011-01-01

    Stochastic Cooling was invented by Simon van der Meer and was demonstrated at the CERN ISR and ICE (Initial Cooling Experiment). Operational systems were developed at Fermilab and CERN. A complete theory of cooling of unbunched beams was developed, and was applied at CERN and Fermilab. Several new and existing rings employ coasting beam cooling. Bunched beam cooling was demonstrated in ICE and has been observed in several rings designed for coasting beam cooling. High energy bunched beams have proven more difficult. Signal suppression was achieved in the Tevatron, though operational cooling was not pursued at Fermilab. Longitudinal cooling was achieved in the RHIC collider. More recently a vertical cooling system in RHIC cooled both transverse dimensions via betatron coupling.

  5. Stability and Phase Noise Tests of Two Cryo-Cooled Sapphire Oscillators

    Science.gov (United States)

    Dick, G. John; Wang, Rabi T.

    1998-01-01

    A cryocooled Compensated Sapphire Oscillator (CSO), developed for the Cassini Ka-band Radio Science experiment, and operating in the 8K - 10K temperature range was previously demonstrated to show ultra-high stability of sigma(sub y) = 2.5 x 10 (exp -15) for measuring times 200 seconds less than or equal to tau less than or equal to 600 seconds using a hydrogen maser as reference. We present here test results for a second unit which allows CSO short-term stability and phase noise to be measured for the first time. Also included are design details of a new RF receiver and an intercomparison with the first CSO unit. Cryogenic oscillators operating below about 10K offer the highest possible short term stability of any frequency sources. However, their use has so far been restricted to research environments due to the limited operating periods associated with liquid helium consumption. The cryocooled CSO is being built in support of the Cassini Ka-band Radio Science experiment and is designed to operate continuously for periods of a year or more. Performance targets are a stability of 3-4 x 10 (exp -15) (1 second less than or equal to tau less than or equal to 100 seconds) and phase noise of -73dB/Hz @ 1Hz measured at 34 GHz. Installation in 5 stations of NASA's deep space network (DSN) is planned in the years 2000 - 2002. In the previous tests, actual stability of the CSO for measuring times tau less than or equal to 200 seconds could not be directly measured, being masked by short-term fluctuations of the H-maser reference. Excellent short-term performance, however, could be inferred by the success of an application of the CSO as local oscillator (L.O.) to the JPL LITS passive atomic standard, where medium-term stability showed no degradation due to L.O. instabilities at a level of (sigma)y = 3 x 10 (exp -14)/square root of tau. A second CSO has now been constructed, and all cryogenic aspects have been verified, including a resonator turn-over temperature of 7.907 K

  6. Testing of a low cooled ceramic nozzle vane under transient conditions

    Energy Technology Data Exchange (ETDEWEB)

    Dilzer, M.; Gutmann, C.; Schulz, A.; Wittig, S. [Univ. of Karlsruhe (Germany). Inst. fuer Thermische Stroemungsmaschinen

    1999-04-01

    At the Institut fuer Thermische Stroemungsmaschinen, University of Karlsruhe (ITS), a design technology has been introduced to reduce the mechanically and especially the thermally induced stresses in ceramic components. The concept is based on a three-layered construction (outer ceramic shell, heat insulating layer, and metallic core) and an optimization of the thicknesses of the single layers, in order to obtain a homogeneous temperature distribution in the ceramic structure. The optimization is performed by finite element analyses in combination with failure probability calculations. This methodology has been applied to increase the reliability of a first stage Sintered Silicon Carbide (SSiC) ceramic nozzle vane of a stationary gas turbine (70 MW/1400 C). As a result is was found that the mechanically and thermally induced loads have been reduced considerably and do not exceed 100 MPa, thus achieving adequate life based upon failure probability calculations. Even in a trip situation (fuel cutoff), when the highest loads do occur, the calculations demonstrate a significantly reduced failure probability. The results of the finite element analyses were verified by simulating the typical operating conditions after fuel cutoff in a test rig.

  7. Performance test of current lead cooled by a cryocooler in low temperature superconducting magnet system

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yeon Suk, E-mail: ychoi@kbsi.re.kr; Kim, Myung Su

    2013-11-15

    Highlights: •The current lead with multi-contact connector in the joint was fabricated for performance test. •The electrical contact resistance in the joint was measured during magnet charging. •The resistances of the joint were 0.4–0.9 mΩ for 40–80 K. •The heat generation due to electrical contact resistance was reduced below 1 W by multiple spring louvers. -- Abstract: In a low temperature superconducting magnet system, heat leakage through current leads is one of the major factors in cryogenic load. The semi-retractable current lead is a good option because the conductive heat leakage can be eliminated after the excitation of the magnet. It is composed of a normal metal element, conducting the current from room temperature to intermediate temperature, and an HTS element, conducting the current down to liquid helium temperature. The normal metal element is disengaged from the HTS element through the multi-contact connector without disturbance to the insulating vacuum space and without requiring complete removal of the normal metal element. The intermediate block with a lockable set point is thermally connected to the first stage of cryocooler and carries current through a strip of louvered material. The electrical contact resistance of multi-contact connector in the intermediate block is measured during magnet charging process. The effects of current level as well as operating temperature on the heat generation in the joint block are also discussed.

  8. Scaling Studies for High Temperature Test Facility and Modular High Temperature Gas-Cooled Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Richard R. Schult; Paul D. Bayless; Richard W. Johnson; James R. Wolf; Brian Woods

    2012-02-01

    The Oregon State University (OSU) High Temperature Test Facility (HTTF) is an integral experimental facility that will be constructed on the OSU campus in Corvallis, Oregon. The HTTF project was initiated, by the U.S. Nuclear Regulatory Commission (NRC), on September 5, 2008 as Task 4 of the 5-year High Temperature Gas Reactor Cooperative Agreement via NRC Contract 04-08-138. Until August, 2010, when a DOE contract was initiated to fund additional capabilities for the HTTF project, all of the funding support for the HTTF was provided by the NRC via their cooperative agreement. The U.S. Department of Energy (DOE) began their involvement with the HTTF project in late 2009 via the Next Generation Nuclear Plant (NGNP) project. Because the NRC's interests in HTTF experiments were only centered on the depressurized conduction cooldown (DCC) scenario, NGNP involvement focused on expanding the experimental envelope of the HTTF to include steady-state operations and also the pressurized conduction cooldown (PCC).

  9. Design, modification and test of the conduction cooled high-current current leads for the superconducting magnet

    Science.gov (United States)

    Peng, Quanling; Cheng, Da; Xu, Fengyu; Yang, Xiangchen; Wang, Ting; Wei, Xiaotao

    2017-09-01

    Conduction cooled current leads, which bring the current from the room temperature terminal down to the cryogenic environment, were used in common recently in large scale superconducting accelerators for its low cost, sample design and low heat load. In practice, the current lead is designed contained in a stainless steel tube. The heat load can be incepted in steps by thermal anchors, where one end is attached to the stainless steel tube, while the other end is connected with the cold shield of the cryomodule. Since the limitation of the welding technique, a thicker stainless steel tube needs to be used, and hence the thermal anchors cannot provide enough pressure to deform the tube enough to be in direct contact with the current lead, which may lead to temperature instability and bring extra heat load to the cryogenic system. An excellent option of epoxy filled current lead can realize the fully contact and reduce the heat load effectively. This paper will present the process of the current lead design, optimization, numerical simulation and cryogenic test, the test results show that the current lead can keep in a stable operation and low heat load.

  10. Development of a test facility for analyzing transients in supercritical water-cooled reactors by fractional scaling analysis

    Energy Technology Data Exchange (ETDEWEB)

    Roberto, Thiago D., E-mail: thiagodbtr@gmail.com [Instituto de Engenharia Nuclear (IEN/CNEN—RJ), Rua Hélio de Almeida, 75 21941-972, Rio de Janeiro Caixa-Postal: 68550, RJ (Brazil); Silva, Mário A. B. da, E-mail: mabs500@gmail.com [Departamento de Energia Nuclear (CTG/UFPE), Av. Professor Luiz Freire, 1000, Recife 50740-540, PE (Brazil); Lapa, Celso M.F., E-mail: lapa@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN—RJ), Rua Hélio de Almeida, 75 21941-972, Rio de Janeiro Caixa-Postal: 68550, RJ (Brazil)

    2016-01-15

    The feasibility of performing experiments using water under supercritical conditions is limited by technical and financial difficulties. These difficulties can be overcome by using model fluids that are characterized by feasible supercritical conditions, that is, lower critical pressure and critical temperature. Experimental investigations are normally used to determine the conditions under which model fluids reliably represent supercritical fluids under steady-state conditions. A fluid-to-fluid scaling approach has been proposed to determine the model fluids that represent supercritical fluids in a transient state. Recently, a similar technique known as fractional scaling analysis was developed to establish the conditions under which experiments can be performed using models that represent transients in prototypes. This paper presents a fractional scaling analysis application to determine parameters for a test facility in which transient conditions in supercritical water-cooled reactors are simulated by using carbon dioxide as a model fluid, whose critical point conditions are more feasible than those of water. Similarity is obtained between water (prototype) and carbon dioxide (model) by depressurization in a simple vessel. The main parameters required for the construction of a future test facility are obtained using the proposed method.

  11. Progress of R&D on water cooled ceramic breeder for ITER test blanket system and DEMO

    Energy Technology Data Exchange (ETDEWEB)

    Kawamura, Yoshinori, E-mail: kawamura.yoshinori@jaea.go.jp [Japan Atomic Energy Agency, 801-1 Mukoyama, Naka, Ibaraki 311-0193 (Japan); Tanigawa, Hisashi; Hirose, Takanori; Enoeda, Mikio [Japan Atomic Energy Agency, 801-1 Mukoyama, Naka, Ibaraki 311-0193 (Japan); Sato, Satoshi [Japan Atomic Energy Agency, 2-4 Shirane Shirakata, Tokai, Ibaraki 319-1195 (Japan); Ochiai, Kentaro [Japan Atomic Energy Agency, 2-166 Omotedate Obuchi, Rokkasho, Aomori 039-3212 (Japan); Konno, Chikara; Edao, Yuki; Hayashi, Takumi [Japan Atomic Energy Agency, 2-4 Shirane Shirakata, Tokai, Ibaraki 319-1195 (Japan); Hoshino, Tsuyoshi; Nakamichi, Masaru; Tanigawa, Hiroyasu [Japan Atomic Energy Agency, 2-166 Omotedate Obuchi, Rokkasho, Aomori 039-3212 (Japan); Nishi, Hiroshi; Suzuki, Satoshi; Ezato, Koichiro; Seki, Yohji [Japan Atomic Energy Agency, 801-1 Mukoyama, Naka, Ibaraki 311-0193 (Japan); Yamanishi, Toshihiko [Japan Atomic Energy Agency, 2-166 Omotedate Obuchi, Rokkasho, Aomori 039-3212 (Japan)

    2016-11-01

    Highlights: • Thermo-hydraulic calculation in the TBM at the water ingress event has been done. • Shielding calculations for the ITER equatorial port #18 were conducted by using C-lite model. • Prototypic pebbles of Be{sub 17}Ti{sub 2} and Be{sub 12}V had a good oxidation property similar to Be{sub 12}Ti pebble. • Li rich Li{sub 2}TiO{sub 3} pebbles were successfully fabricated using the emulsion method by controlling sintering atmosphere. • New tritium production/recovery experiments at FNS have been started by using ionization chamber as on-line gas monitor. - Abstract: The development of a water cooled ceramic breeder (WCCB) test blanket module (TBM) is being performed as one of the most important steps toward DEMO blanket in Japan. For the TBM testing and development of DEMO blanket, R&D has been performed on the module fabrication technology, breeder and multiplier pebble fabrication technology, tritium production rate evaluation, as well as structural and safety design activities. The fabrication of full-scale first wall, side walls, breeder pebble bed box and back wall was completed, and assembly of TBM with box structure was successfully achieved. Development of advanced breeder and multiplier pebbles for higher chemical stability was continued for future DEMO blanket application. From the view point of TBM test result evaluation and DEMO blanket performance design, the development of the blanket tritium transport simulation technology, investigation of the TBM neutron measurement technology and the evaluation of the tritium production and recovery test using D-T neutron in the fusion neutron source (FNS) facility has been performed. This paper provides an overview of the recent achievements of the development of the WCCB Blanket in Japan.

  12. Development and test of the $\\rm CO_2$ evaporative cooling system for the LHCb UT Tracker Upgrade

    CERN Document Server

    Coelli, Simone

    2017-01-01

    Abstract: The LHCb upgrade requires a new silicon strip tracker detector placed between the vertex locator and the magnet. The new detector will have improved performance in charged particle tracking and triggering. The front-end electronics will be in the active area, close to the sensors: this is a key feature driving the mechanical and cooling detector design, together with the requirement to make the sensors work below −5°C, to withstand radiation damage. The new design exploits a cooling system based on $\\rm CO_2$ evaporation at temperatures around −25°C. The support structure for the sensor modules is a lightweight carbon fiber mechanical structure embedding a cooling pipe, designed to pass underneath the read-out ASICs, which are the main thermal power sources to be cooled down. Here a description of the detector will be given, with a main focus on the cooling system and on the progress done to its qualification.

  13. Selective nanoscale growth of lattice mismatched materials

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung-Chang; Brueck, Steven R. J.

    2017-06-20

    Exemplary embodiments provide materials and methods of forming high-quality semiconductor devices using lattice-mismatched materials. In one embodiment, a composite film including one or more substantially-single-particle-thick nanoparticle layers can be deposited over a substrate as a nanoscale selective growth mask for epitaxially growing lattice-mismatched materials over the substrate.

  14. Self-Pressurization and Spray Cooling Simulations of the Multipurpose Hydrogen Test Bed (MHTB) Ground-Based Experiment

    Science.gov (United States)

    Kartuzova, O.; Kassemi, M.; Agui, J.; Moder, J.

    2014-01-01

    This paper presents a CFD (computational fluid dynamics) model for simulating the self-pressurization of a large scale liquid hydrogen storage tank. In this model, the kinetics-based Schrage equation is used to account for the evaporative and condensing interfacial mass flows. Laminar and turbulent approaches to modeling natural convection in the tank and heat and mass transfer at the interface are compared. The flow, temperature, and interfacial mass fluxes predicted by these two approaches during tank self-pressurization are compared against each other. The ullage pressure and vapor temperature evolutions are also compared against experimental data obtained from the MHTB (Multipuprpose Hydrogen Test Bed) self-pressurization experiment. A CFD model for cooling cryogenic storage tanks by spraying cold liquid in the ullage is also presented. The Euler- Lagrange approach is utilized for tracking the spray droplets and for modeling interaction between the droplets and the continuous phase (ullage). The spray model is coupled with the VOF (volume of fluid) model by performing particle tracking in the ullage, removing particles from the ullage when they reach the interface, and then adding their contributions to the liquid. Droplet ullage heat and mass transfer are modeled. The flow, temperature, and interfacial mass flux predicted by the model are presented. The ullage pressure is compared with experimental data obtained from the MHTB spray bar mixing experiment. The results of the models with only droplet/ullage heat transfer and with heat and mass transfer between the droplets and ullage are compared.

  15. Flexible Residential Test Facility: Impact of Infiltration and Ventilation on Measured Cooling Season Energy and Moisture Levels

    Energy Technology Data Exchange (ETDEWEB)

    Parker, Danny S. [BA-PIRC/Florida Solar Energy Center, Cocoa, FL (United States); Cummings, Jamie E. [BA-PIRC/Florida Solar Energy Center, Cocoa, FL (United States); Vieira, Robin K. [BA-PIRC/Florida Solar Energy Center, Cocoa, FL (United States); Fairey, III, Phillip W. [BA-PIRC/Florida Solar Energy Center, Cocoa, FL (United States); Sherwin, John S. [BA-PIRC/Florida Solar Energy Center, Cocoa, FL (United States); Withers, Jr., Charles [BA-PIRC/Florida Solar Energy Center, Cocoa, FL (United States); Hoak, David [BA-PIRC/Florida Solar Energy Center, Cocoa, FL (United States); Beal, David [BA-PIRC/Florida Solar Energy Center, Cocoa, FL (United States)

    2016-09-01

    Air infiltration and ventilation in residential buildings is a very large part of the heating loads, but empirical data regarding the impact on space cooling has been lacking. Moreover, there has been little data on how building tightness might relate to building interior moisture levels in homes in a hot and humid climate. To address this need, BA-PIRC has conducted research to assess the moisture and cooling load impacts of airtightness and mechanical ventilation in two identical laboratory homes in the hot-humid climate over the cooling season.

  16. Flexible Residential Test Facility: Impact of Infiltration and Ventilation on Measured Cooling Season Energy and Moisture Levels

    Energy Technology Data Exchange (ETDEWEB)

    Parker, D.; Kono, J.; Vieira, R.; Fairey, P.; Sherwin, J.; Withers, C.; Hoak, D.; Beal, D.

    2014-05-01

    Air infiltration and ventilation in residential buildings is a very large part of the heating loads, but empirical data regarding the impact on space cooling has been lacking. Moreover, there has been little data on how building tightness might relate to building interior moisture levels in homes in a hot and humid climate. To address this need, BA-PIRC has conducted research to assess the moisture and cooling load impacts of airtightness and mechanical ventilation in two identical laboratory homes in the hot-humid climate over the cooling season.

  17. Thermal-mechanical and thermal-hydraulic integrated study of the Helium-Cooled Lithium Lead Test Blanket Module

    Energy Technology Data Exchange (ETDEWEB)

    Chiovaro, P., E-mail: pg.chiovaro@din.unipa.it [Dipartimento di Ingegneria Nucleare, Universita di Palermo, Palermo (Italy); Di Maio, P.A.; Giammusso, R.; Lupo, Q.; Vella, G. [Dipartimento di Ingegneria Nucleare, Universita di Palermo, Palermo (Italy)

    2010-12-15

    The Helium-Cooled Lithium Lead Test Blanket Module (HCLL-TBM) is one of the two TBM to be installed in an ITER equatorial port since day 1 of operation, with the specific aim to investigate the main concept functionalities and issues such as high efficiency helium cooling, resistance to thermo-mechanical stresses, manufacturing techniques, as well as tritium transport, magneto-hydrodynamics effects and corrosion. In particular, in order to show a DEMO-relevant thermo-mechanical and thermal-hydraulic behavior, the HCLL-TBM has to meet several requirements especially as far as its coolant thermofluid-dynamic conditions and its thermal-mechanical field are concerned. The present paper is focused on the assessment of the HCLL-TBM thermal-mechanical performances under both nominal and accidental load conditions, by adopting a computational approach based on the Finite Element Method. A realistic 3D finite element model of the whole HCLL-TBM, in the horizontal first wall design has been set up, consisting of about 597,000 elements and 767,000 nodes. In particular, since the thermal fields of both the module and the coolant are strictly coupled, the helium flow domain has been modeled too and a thermal contact model has been set up to properly simulate the convective heat transfer between the structure wall and the coolant. Pure conductive heat transfer has been assumed within the Pb-Li eutectic alloy of the breeder units. The volumetric density of the nuclear deposited power, recently calculated at Department of Nuclear Engineering of the University of Palermo by the MCNP 4C code, has been applied as distributed thermal load in order to assess the potential influence on the module thermo-mechanical performances of the markedly non-uniform poloidal and toroidal distributions that have been predicted within the Segment Box. Different loading scenarios have been considered as to the heat flux onto the module First Wall. Steady state and transient thermal-mechanical analyses

  18. Mismatch Receptive Fields in Mouse Visual Cortex.

    Science.gov (United States)

    Zmarz, Pawel; Keller, Georg B

    2016-11-23

    In primary visual cortex, a subset of neurons responds when a particular stimulus is encountered in a certain location in visual space. This activity can be modeled using a visual receptive field. In addition to visually driven activity, there are neurons in visual cortex that integrate visual and motor-related input to signal a mismatch between actual and predicted visual flow. Here we show that these mismatch neurons have receptive fields and signal a local mismatch between actual and predicted visual flow in restricted regions of visual space. These mismatch receptive fields are aligned to the retinotopic map of visual cortex and are similar in size to visual receptive fields. Thus, neurons with mismatch receptive fields signal local deviations of actual visual flow from visual flow predicted based on self-motion and could therefore underlie the detection of objects moving relative to the visual flow caused by self-motion. VIDEO ABSTRACT.

  19. Zero energy buildings and mismatch compensation factors

    DEFF Research Database (Denmark)

    Lund, Henrik; Marszal, Anna Joanna; Heiselberg, Per

    2011-01-01

    This paper takes an overall energy system approach to analysing the mismatch problem of zero energy and zero emission buildings (ZEBs). The mismatch arises from hourly differences in energy production and consumption at the building level and results in the need for exchange of electricity via...... of the energy production unit. Based on historical data for the electricity supply area in western Denmark, this paper makes a first attempt to quantify mismatch compensation factors. The results indicate that such compensation factors are a little below one for buildings with photovoltaics (PV) and a little...... the public grid even though the building has an annual net-exchange of zero. This paper argues that, when looked upon from the viewpoint of the overall electricity supply system, a mismatch can be both negative and positive. Moreover, there are often both an element of levelling out mismatches between...

  20. Mismatching Perspectives and Pacific Transculturality

    Directory of Open Access Journals (Sweden)

    Anne Holden Rønning

    2013-01-01

    Full Text Available Increased critical consciousness and awareness of interculturality in a global and glocal context at the beginning of the twenty-first century has increasingly used the concept of transculturation when discussing modernities. Politically transculturation can be used to describe processes of negotiation in contemporary society that lead to social awareness and solidarity, as well as ensuring the continuity of societies. The fusing of cultural forms leads to a mismatching of perspectives, hence some critics have preferred to use the terms translation and/or transliteracy to describe this concept. Transculturation is related to the “normal processes of artistic borrowing and influence, by which any culture makes part of its contribution to the conversation of mankind,” as Les Murray maintained, and “it engages multiple lines of difference simultaneously” with overlapping boundaries (Rogers 491. Referring to various authors and linking it to cultural appropriation and border crossings, this article examines how the narrative expression of Both Sides of the Moon, to cite the title of Alan Duff’s book, is a key feature of Pacific writing, in an area where centuries of migration from near and far have exposed different cultures to each other on social, political, linguistic and aesthetic levels. These ‘contact zones’, to use Mary Pratt’s words, provide the reader with constantly moving translated identities, cultural hybridity and a use of language that has a highly local significance in a global context.

  1. Preliminary Tests of Blowers of Three Designs Operating in Conjunction with a Wing-Duct Cooling System for Radial Engines, Special Report

    Science.gov (United States)

    Biermann, David; Valentine, E. Floyd

    1939-01-01

    This paper is one of several dealing with methods intended to reduce the drag of present-day radial engine installations and improve the cooling at zero and low air speeds, The present paper describes model wind-tunnel tests of blowers of three designs tested in conjunction with a wing-nacelle combination. The principle of operation involved consists of drawing cooling air into ducts located in the wing root at the point of maximum slipstream velocity, passing the air through the engine baffles from rear to front, and exhausting the air through an annular slot located between the propeller and the engine with the aid of a blower mounted on the spinner. The test apparatus consisted essentially of a stub wing having a 5-foot chord and a 15-foot span, an engine nacelle of 20 inches diameter enclosing a 25-horsepower electric motor, and three blowers mounted on propeller spinners. Two of the blowers utilize centrifugal force while the other uses the lift from airfoils to force the air out radially through the exit slot. Maximum efficiencies of over 70 percent were obtained for the system as a whole. Pressures were measured over the entire flight range which were in excess of those necessary to cool present-day engines, The results indicated that blowers mounted on propeller spinners could be built sufficiently powerful and efficient to warrant their use as the only, or chief, means of forcing air through the cooling system, so that cooling would be independent of the speed of the airplane.

  2. Flight Test Research for APU Cooling System of Transport Airplane%运输类飞机APU冷却系统飞行试验研究

    Institute of Scientific and Technical Information of China (English)

    李丽

    2014-01-01

    The lfight test of an Auxiliary Power Unit (APU) compartment cooling system is one subject of the certiifcation tests that must be demonstrated according to airworthiness standards for transport category airplanes. On the basis of an APU cooling system, a whole typical lfight proifle temperature data were studied. The methods of airworthiness demonstration lfight test about APU the cooling test was determined on the basis of analyzing the test results.%运输类飞机适航标准规定APU冷却系统飞行试验是APU系统适航取证试飞必须进行的科目之一。以某型民用飞机的APU冷却系统为对象,研究一个典型飞行剖面内APU冷却系统相关温度参数的变化情况,对试验结果进行了分析,提出APU冷却系统适航验证试飞方法。

  3. INITIAL COOLING EXPERIMENT (ICE)

    CERN Multimedia

    1978-01-01

    ICE was built in 1977, in a record time of 9 months, using the modified bending magnets of the g-2 muon storage ring. Its purpose was to verify the validity of stochastic and electron cooling for the antiproton project, to be launched in 1978. Already early in 1978, stochastic cooling proved a resounding success, such that the antiproton (p-pbar)project was entirely based on it. Tests of electron cooling followed later: protons of 46 MeV kinetic energy were cooled with an electron beam of 26 kV and 1.3 A. The cage seen prominently in the foreground houses the HV equipment, adjacent to the "cooler" installed in a straight section of the ring. With some modifications, the cooler was later transplanted into LEAR (Low Energy Antiproton Ring) and then, with further modifications, into the AD (Antiproton Decelerator), where it cools antiprotons to this day (2006). See also: 7711282, 7802099, 7908242.

  4. Influence of sequence mismatches on the specificity of recombinase polymerase amplification technology.

    Science.gov (United States)

    Daher, Rana K; Stewart, Gale; Boissinot, Maurice; Boudreau, Dominique K; Bergeron, Michel G

    2015-04-01

    Recombinase polymerase amplification (RPA) technology relies on three major proteins, recombinase proteins, single-strand binding proteins, and polymerases, to specifically amplify nucleic acid sequences in an isothermal format. The performance of RPA with respect to sequence mismatches of closely-related non-target molecules is not well documented and the influence of the number and distribution of mismatches in DNA sequences on RPA amplification reaction is not well understood. We investigated the specificity of RPA by testing closely-related species bearing naturally occurring mismatches for the tuf gene sequence of Pseudomonas aeruginosa and/or Mycobacterium tuberculosis and for the cfb gene sequence of Streptococcus agalactiae. In addition, the impact of the number and distribution of mismatches on RPA efficiency was assessed by synthetically generating 14 types of mismatched forward primers for detecting five bacterial species of high diagnostic relevance such as Clostridium difficile, Staphylococcus aureus, S. agalactiae, P. aeruginosa, and M. tuberculosis as well as Bacillus atropheus subsp. globigii for which we use the spores as internal control in diagnostic assays. A total of 87 mismatched primers were tested in this study. We observed that target specific RPA primers with mismatches (n > 1) at their 3'extrimity hampered RPA reaction. In addition, 3 mismatches covering both extremities and the center of the primer sequence negatively affected RPA yield. We demonstrated that the specificity of RPA was multifactorial. Therefore its application in clinical settings must be selected and validated a priori. We recommend that the selection of a target gene must consider the presence of closely-related non-target genes. It is advisable to choose target regions with a high number of mismatches (≥36%, relative to the size of amplicon) with respect to closely-related species and the best case scenario would be by choosing a unique target gene.

  5. Quality of Experience for Large Ultra-High-Resolution Tiled Displays with Synchronization Mismatch

    Directory of Open Access Journals (Sweden)

    Deshpande Sachin

    2011-01-01

    Full Text Available This paper relates to quality of experience when viewing images, video, or other content on large ultra-high-resolution displays made from individual display tiles. We define experiments to measure vernier acuity caused by synchronization mismatch for moving images. The experiments are used to obtain synchronization mismatch acuity threshold as a function of object velocity and as a function of occlusion or gap width. Our main motivation for measuring the synchronization mismatch vernier acuity is its relevance in the application of tiled display systems, which create a single contiguous image using individual discrete panels arranged in a matrix with each panel utilizing a distributed synchronization algorithm to display parts of the overall image. We also propose a subjective assessment method for perception evaluation of synchronization mismatch for large ultra-high-resolution tiled displays. For this, we design a synchronization mismatch measurement test video set for various tile configurations for various interpanel synchronization mismatch values. The proposed method for synchronization mismatch perception can evaluate tiled displays with or without tile bezels. The results from this work can help during design of low-cost tiled display systems, which utilize distributed synchronization mechanisms for a contiguous or bezeled image display.

  6. Danish Cool

    DEFF Research Database (Denmark)

    Toft, Anne Elisabeth

    2016-01-01

    Danish Cool. Keld Helmer-Petersen, Photography and the Photobook Handout exhibition text in English and Chinese by Anne Elisabeth Toft, Curator The exhibition Danish Cool. Keld Helmer-Petersen, Photography and the Photobook presents the ground-breaking work of late Danish photographer Keld Helmer...

  7. Reduced-scale water test of natural circulation for decay heat removal in loop-type sodium-cooled fast reactor

    Energy Technology Data Exchange (ETDEWEB)

    Murakami, T., E-mail: murakami@criepi.denken.or.jp [Central Research Institute of Electric Power Industry, 1646 Abiko, Chiba (Japan); Eguchi, Y., E-mail: eguchi@criepi.denken.or.jp [Central Research Institute of Electric Power Industry, 1646 Abiko, Chiba (Japan); Oyama, K., E-mail: kazuhiro_oyama@mfbr.mhi.co.jp [Mitsubishi FBR Systems, Inc., 2-34-17 Jinguumae, Shibuya, Tokyo (Japan); Watanabe, O., E-mail: osamu4_watanabe@mfbr.mhi.co.jp [Mitsubishi FBR Systems, Inc., 2-34-17 Jinguumae, Shibuya, Tokyo (Japan)

    2015-07-15

    Highlights: • The natural circulation characteristics of a loop-type SFR are examined by a water test. • The performance of decay heat removal system is evaluated using a similarity law. • The effects of flow deviation in the parallel piping of a primary loop are clarified. • The reproducibility of the natural circulation test is confirmed. - Abstract: Water tests of a loop-type sodium-cooled fast reactor have been conducted to physically evaluate the natural circulation characteristics. The water test apparatus was manufactured as a 1/10-scale mock-up of the Japan Sodium-Cooled Fast Reactor, which adopts a decay heat removal system (DHRS) utilizing natural circulation. Tests simulating a variety of events and operation conditions clarified the thermal hydraulic characteristics and core-cooling performance of the natural circulation in the primary loop. Operation conditions such as the duration of the pump flow coast-down and the activation time of the DHRS affect the natural circulation characteristics. A long pump flow coast-down cools the upper plenum of the reactor vessel (RV). This causes the loss of the buoyant force in the RV. The test result indicates that a long pump flow coast-down tends to result in a rapid increase in the core temperature because of the loss of the buoyant force. The delayed activation of the DHRS causes a decrease in the natural circulation flow rate and a temperature rise in the RV. Flow rate deviation and a reverse flow appear in the parallel cold-leg piping in some events, which cause thermal stratification in the cold-leg piping. The DHRS prevents the core temperature from fatally rise even for the most severe design-basis event, in which sodium leakage in a secondary loop of the DHRS and the opening failure of a single damper of the air cooler occur simultaneously. In the water test for the case of siphon break in the primary loop, which is one of the design extension conditions, a circulation flow consisting of ascendant

  8. The Impact of Public Policies on Skill Mismatch : cross-country analysis in OECD economies

    OpenAIRE

    Mauriès, Arthur-Alexandre

    2016-01-01

    Governments aim at reducing skill mismatch because of the adverse effects that it can trigger at the individual and firm level as well as at the country level. Skill mismatch has been defined as a persistent phenomenon with long lasting cross-country differences (Mavromaras et al., 2013). This phenomenon could thus be explained by equivalent cross-country differences in national public policies. The purpose of this thesis is to test the impact of public policies on the probability of being sk...

  9. Water-cooled electronics

    CERN Document Server

    Dumont, G; Righini, B

    2000-01-01

    LHC experiments demand on cooling of electronic instrumentation will be extremely high. A large number of racks will be located in underground caverns and counting rooms, where cooling by conventional climatisation would be prohibitively expensive. A series of tests on the direct water cooling of VMEbus units and of their standard power supplies is reported. A maximum dissipation of 60 W for each module and more than 1000 W delivered by the power supply to the crate have been reached. These values comply with the VMEbus specifications. (3 refs).

  10. Educational Mismatches and Labor Market Outcomes: Evidence from Both Vertical and Horizontal Mismatches in Thailand

    Science.gov (United States)

    Pholphirul, Piriya

    2017-01-01

    Purpose: Educational mismatches constitute negative impacts on labor markets in most countries, Thailand is no exception. The purpose of this paper is to quantify the degree of educational mismatch in Thailand and its impacts on labor market outcomes. Design/methodology/approach: This study analyzes data obtained from Thailand's Labor Force Survey…

  11. Does PGA external stenting reduce compliance mismatch in venous grafts?

    Directory of Open Access Journals (Sweden)

    Zou Liang-jian

    2007-04-01

    Full Text Available Abstract Background Autogenous vein grafting is widely used in regular bypassing procedures. Due to its mismatch with the host artery in both mechanical property and geometry, the graft often over expands under high arterial blood pressure and forms a step-depth where eddy flow develops, thus causing restenosis, fibrous graft wall, etc. External stents, such as sheaths being used to cuff the graft, have been introduced to eliminate these mismatches and increase the patency. Although histological and immunochemical studies have shown some positive effects of the external stent, the mechanical mismatch under the protection of an external stent remains poorly analyzed. Methods In this study, the jugular veins taken from hypercholesterolemic rabbits were transplanted into the carotid arteries, and non-woven polyglycolic acid (PGA fabric was used to fabricate the external stents to study the effect of the biodegradable external stent. Eight weeks after the operation, the grafts were harvested to perform mechanical tests and histological examinations. An arc tangent function was suggested to describe the relationship between pressure and cross-sectional area to analyse the compliance of the graft. Results The results from the mechanical tests indicated that grafts either with or without external stents displayed large compliance in the low-pressure range and were almost inextensible in the high-pressure range. This was very different from the behavior of the arteries or veins in vivo. The data from histological tests showed that, with external stents, collagen fibers were more compact, whilst those in the graft without protection were looser and thicker. No elastic fiber was found in either kind of grafts. Furthermore, grafts without protection were over-expanded which resulted in much bigger cross-sectional areas. Conclusion The PGA external extent contributes little to the reduction of the mechanical mismatch between the graft and its host artery

  12. Leak tightness tests on actively cooled plasma facing components: Lessons learned from Tore Supra experience and perspectives for the new fusion machines

    Energy Technology Data Exchange (ETDEWEB)

    Chantant, M., E-mail: michel.chantant@cea.fr; Lambert, R.; Gargiulo, L.; Hatchressian, J.-C.; Guilhem, D.; Samaille, F.; Soler, B.

    2015-10-15

    Highlights: • Test procedures for the qualification of the tightness of actively cooled plasma facing components were defined. • The test is performed after the component manufacturing and before its set-up in the vacuum vessel. • It allows improving the fusion machine availability. • The lessons of tests over 20 years at Tore Supra are presented. - Abstract: The fusion machines under development or construction (ITER, W7X) use several hundreds of actively cooled plasma facing components (ACPFC). They are submitted to leak tightness requirements in order to get an appropriate vacuum level in the vessel to create the plasma. During the ACPFC manufacturing and before their installation in the machine, their leak tightness performance must be measured to check that they fulfill the vacuum requirements. A relevant procedure is needed which allows to segregate potential defects. It must also be optimized in terms of test duration and costs. Tore Supra, as an actively cooled Tokamak, experienced several leaks on ACPFCs during the commissioning and during the operation of the machine. A test procedure was then defined and several test facilities were set-up. Since 1990 the tightness of all the new ACPFCs is systematically tested before their installation in Tore Supra. During the qualification test, the component is set up in a vacuum test tank, and its cooling circuits are pressurized with helium. It is submitted to 3 temperature cycles from room temperature up to the baking temperature level in Tore Supra (200 °C) and two pressurization tests are performed (6 MPa at room temperature and 4 MPa at 200 °C) at each stage. At the end of the last cycle when the ACPFC is at room temperature and pressurized with helium at 6 MPa, the measured leak rate must be lower than 5 × 10{sup −11} Pa m{sup 3} s{sup −1}, the pressure in the test tank being <5 × 10{sup −5} Pa. A large experience has been gained on ACPFCs with carbon parts on stainless steel and Cu

  13. On the safety and performance demonstration tests of Prototype Gen-IV Sodium-Cooled Fast Reactor and validation and verification of computational codes

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Bum; Jeong, Ji Young; Lee, Tae Ho; Kim, Sung Kyun; Euh, Dong Jin; Joo, Hyung Kook [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    The design of Prototype Gen-IV Sodium-Cooled Fast Reactor (PGSFR) has been developed and the validation and verification (V and V) activities to demonstrate the system performance and safety are in progress. In this paper, the current status of test activities is described briefly and significant results are discussed. The large-scale sodium thermal-hydraulic test program, Sodium Test Loop for Safety Simulation and Assessment-1 (STELLA-1), produced satisfactory results, which were used for the computer codes V and V, and the performance test results of the model pump in sodium showed good agreement with those in water. The second phase of the STELLA program with the integral effect tests facility, STELLA-2, is in the detailed design stage of the design process. The sodium thermal-hydraulic experiment loop for finned-tube sodium-to-air heat exchanger performance test, the intermediate heat exchanger test facility, and the test facility for the reactor flow distribution are underway. Flow characteristics test in subchannels of a wire-wrapped rod bundle has been carried out for safety analysis in the core and the dynamic characteristic test of upper internal structure has been performed for the seismic analysis model for the PGSFR. The performance tests for control rod assemblies (CRAs) have been conducted for control rod drive mechanism driving parts and drop tests of the CRA under scram condition were performed. Finally, three types of inspection sensors under development for the safe operation of the PGSFR were explained with significant results.

  14. Wavelength mismatch effect in electromagnetically induced absorption

    Science.gov (United States)

    Bharti, Vineet; Wasan, Ajay; Natarajan, Vasant

    2016-07-01

    We present a theoretical investigation of the phenomenon of electromagnetically induced absorption (EIA) in a 4-level system consisting of vee and ladder subsystems. The four levels are coupled using one weak probe field, and two strong control fields. We consider an experimental realization using energy levels of Rb. This necessitates dealing with different conditions of wavelength mismatch-near-perfect match where all three wavelengths are approximately equal; partial mismatch where the wavelength of one control field is less than the other fields; and complete mismatch where all three wavelengths are unequal. We present probe absorption profiles with Doppler averaging at room temperature to account for experiments in a room temperature Rb vapor cell. Our analysis shows that EIA resonances can be studied using Rydberg states excited with diode lasers.

  15. Wavelength mismatch effect in electromagnetically induced absorption

    CERN Document Server

    Bharti, Vineet; Natarajan, Vasant

    2016-01-01

    We present a theoretical investigation of the phenomenon of electromagnetically induced absorption (EIA) in a 4-level system consisting of vee and ladder subsystems. The four levels are coupled using one weak probe field, and two strong control fields. We consider an experimental realization using energy levels of Rb. This necessitates dealing with different conditions of wavelength mismatch---near-perfect match where all three wavelengths are approximately equal; partial mismatch where the wavelength of one control field is less than the other fields; and complete mismatch where all three wavelengths are unequal. We present probe absorption profiles with Doppler averaging at room temperature to account for experiments in a room temperature Rb vapor cell. Our analysis shows that EIA resonances can be studied using Rydberg states excited with diode lasers.

  16. Second sector cool down

    CERN Multimedia

    2007-01-01

    At the beginning of July, cool-down is starting in the second LHC sector, sector 4-5. The cool down of sector 4-5 may occasionally generate mist at Point 4, like that produced last January (photo) during the cool-down of sector 7-8.Things are getting colder in the LHC. Sector 7-8 has been kept at 1.9 K for three weeks with excellent stability (see Bulletin No. 16-17 of 16 April 2007). The electrical tests in this sector have got opt to a successful start. At the beginning of July the cryogenic teams started to cool a second sector, sector 4-5. At Point 4 in Echenevex, where one of the LHC’s cryogenic plants is located, preparations for the first phase of the cool-down are underway. During this phase, the sector will first be cooled to 80 K (-193°C), the temperature of liquid nitrogen. As for the first sector, 1200 tonnes of liquid nitrogen will be used for the cool-down. In fact, the nitrogen circulates only at the surface in the ...

  17. Gauge cooling for the singular-drift problem in the complex Langevin method --a test in Random Matrix Theory for finite density QCD

    CERN Document Server

    Nagata, Keitaro; Shimasaki, Shinji

    2016-01-01

    Recently, the complex Langevin method has been applied successfully to finite density QCD either in the deconfinement phase or in the heavy dense limit with the aid of a new technique called the gauge cooling. In the confinement phase with light quarks, however, convergence to wrong limits occurs due to the singularity in the drift term caused by small eigenvalues of the Dirac operator including the mass term. We propose that this singular-drift problem should also be overcome by the gauge cooling with different criteria for choosing the complexified gauge transformation. The idea is tested in chiral Random Matrix Theory for finite density QCD, where exact results are reproduced at zero temperature with light quarks. It is shown that the gauge cooling indeed changes drastically the eigenvalue distribution of the Dirac operator measured during the Langevin process. Despite its non-holomorphic nature, this eigenvalue distribution has a universal diverging behavior at the origin in the chiral limit due to a gene...

  18. Simulation of the Passive Condensation Cooling Tank of the PASCAL Test Facility using the Component Thermal-hydraulic Analysis Code CUPID

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Hyoung Kyu; Lee, Seung Jun; Yoon, Han Young [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2012-05-15

    The need for a multi-dimensional analysis of transient thermal hydraulic phenomena in a component of a nuclear reactor is increasing with the advanced design features, such as a direct vessel injection system, a gravity-driven safety injection system, and a passive cooling system. Motivated by this, the development of a new thermal-hydraulic analysis code, named CUPID, is in progress at KAERI (Korea Atomic Energy Research Institute). Its numerical solver and two-phase flow models have been verified against standard conceptual problems of single and two-phase flows and validated for thermal-hydraulic experiments in our previous studies. The simulation of the passive secondary cooling system, PAFS (Passive Auxiliary Feedwater System) has been considered as one of the practical applications of CUPID. In the present study, the PCCT (Passive Condensation Cooling Tank) of the PASCAL test facility was analyzed with CUPID prior to simulating the prototype PAFS system. The objectives of the PASCAL simulation were to validate physical models of CUPID and its applicability to the PAFS analysis. This paper presents the two-dimensional transient calculation results and the comparisons with the experimental data

  19. Gauge cooling for the singular-drift problem in the complex Langevin method — a test in Random Matrix Theory for finite density QCD

    Science.gov (United States)

    Nagata, Keitaro; Nishimura, Jun; Shimasaki, Shinji

    2016-07-01

    Recently, the complex Langevin method has been applied successfully to finite density QCD either in the deconfinement phase or in the heavy dense limit with the aid of a new technique called the gauge cooling. In the confinement phase with light quarks, however, convergence to wrong limits occurs due to the singularity in the drift term caused by small eigenvalues of the Dirac operator including the mass term. We propose that this singular-drift problem should also be overcome by the gauge cooling with different criteria for choosing the complexified gauge transformation. The idea is tested in chiral Random Matrix Theory for finite density QCD, where exact results are reproduced at zero temperature with light quarks. It is shown that the gauge cooling indeed changes drastically the eigenvalue distribution of the Dirac operator measured during the Langevin process. Despite its non-holomorphic nature, this eigenvalue distribution has a universal diverging behavior at the origin in the chiral limit due to a generalized Banks-Casher relation as we confirm explicitly.

  20. Mismatch and noise in modern IC processes

    CERN Document Server

    Marshall, Andrew

    2009-01-01

    Component variability, mismatch, and various noise effects are major contributors to design limitations in most modern IC processes. Mismatch and Noise in Modern IC Processes examines these related effects and how they affect the building block circuits of modern integrated circuits, from the perspective of a circuit designer.Variability usually refers to a large scale variation that can occur on a wafer to wafer and lot to lot basis, and over long distances on a wafer. This phenomenon is well understood and the effects of variability are included in most integrated circuit design with the use

  1. An analytical study of mismatched complementary media

    CERN Document Server

    Zhu, Lin; Ma, Hongru

    2016-01-01

    Complementary media (CM) interacting with arbitrarily situated obstacles are usually less discussed. In this paper, an analytical framework based on multiple scattering theory is established for analyzing such a mismatched case. As examples, CM-based devices, i.e., a superlens and superscatterer, are discussed. From an analysis, the cancellation mechanism of the mismatched CM is studied. In addition, numerical results are provided for illustration. Moreover, further study shows that such cancellation effects might rely on specific conditions. Actually, the conclusions are not restricted to any specific frequencies; they could be extended to many other areas including applications to active cloaking, antennas, and wireless power transfer.

  2. SERI Desiccant Cooling Test Facility. Status report. Preliminary data on the performance of a rotary parallel-passage silica-gel dehumidifier

    Energy Technology Data Exchange (ETDEWEB)

    Schultz, K.J.

    1986-04-01

    This report describes the SERI Desiccant Cooling Test Facility. The facility can test bench-scale rotary dehumidifiers over a wide range of controlled conditions. We constructed and installed in the test loop a prototype parallel-passage rotary dehumidifier that has spirally wound polyester tape coated with silica gel. The initial tests gave satisfactory results indicating that approximately 90% of the silica gel was active and the overall Lewis number of the wheel was near unity. The facility has several minor difficulties including an inability to control humidity satisfactorily and nonuniform and highly turbulent inlet velocities. To completely validate the facility requires a range of dehumidifier designs. Several choices are available including constructing a second parallel-passage dehumidifier with the passage spacing more uniform.

  3. Do anticodons of misacylated tRNAs preferentially mismatch codons coding for the misloaded amino acid?

    Directory of Open Access Journals (Sweden)

    Seligmann Hervé

    2010-05-01

    Full Text Available Abstract Background Accurate amino acid insertion during peptide elongation requires tRNAs loaded by cognate amino acids and that anticodons match codons. However, tRNA misloading does not necessarily cause misinsertions: misinsertion is avoided when anticodons mismatch codons coding for misloaded amino acids. Presentation of the hypothesis Occasional compensation of misacylation by codon-anticodon mismatch necessarily occurs. Putatively, occasional error compensation may be enhanced beyond the random combination of independent errors in tRNA loading and codon-anticodon interactions: tRNA misacylation might alter potentials for codon-anticodon mismatches, perhaps specifically increasing potentials for mismatching those codons coding for the misacylated non-cognate amino acid. This hypothetical phenomenon is called 'error coordination', in distinction from 'error compensation' that assumes independence between misacylation and mismatch. Testing the hypothesis Eventually, the hypothesis should be tested for each combination of amino acid misacylation and codon-anticodon mismatch, by comparing stabilities or frequencies of mismatched codon-anticodon duplexes formed by tRNAs loaded by their cognate amino acid with stabilities formed by that tRNA when misloaded with the amino acid coded by the mismatched codon. Competitive mismatching experiments between misloaded and correctly loaded tRNAs could also be useful, yet more sophisticated experiments. Implications of the hypothesis Detecting error coordination implies estimating error compensation, which also promotes protein synthesis accuracy. Hence even in the absence of evidence for error coordination, experiments would yield very useful insights into misacylation and mismatch processes. In case experiments consider post-transcriptional RNA modifications (especially at wobble positions, results on codon-anticodon mismatches would enable significant improvements and sophistications of secondary

  4. A new Newton's law of cooling?

    Science.gov (United States)

    Kleiber, M

    1972-12-22

    Several physiologists confuse Fourier's law of animal heat flow with Newton's law of cooling. A critique of this error in 1932 remained ineffective. In 1969 Molnar tested Newton's cooling law. In 1971 Strunk found Newtonian cooling unrealistic for animals. Unfortunately, he called the Fourier formulation of animal heat flow, requiring post-Newtonian observations, a "contemporary Newtonian law of cooling."

  5. LHC cooling gains ground

    CERN Multimedia

    Huillet-Miraton Catherine

    The nominal cryogenic conditions of 1.9 K have been achieved in sectors 5-6 and 7-8. This means that a quarter of the machine has reached the nominal conditions for LHC operation, having attained a temperature of below 2 K (-271°C), which is colder than interstellar space! Elsewhere, the cryogenic system in Sector 8-1 has been filled with liquid helium and cooled to 2K and will soon be available for magnet testing. Sectors 6-7 and 2-3 are being cooled down and cool-down operations have started in Sector 3-4. Finally, preparations are in hand for the cool-down of Sector 1-2 in May and of Sector 4-5, which is currently being consolidated. The LHC should be completely cold for the summer. For more information: http://lhc.web.cern.ch/lhc/Cooldown_status.htm.

  6. Proof-of-Concept Testing of the Passive Cooling System (T-CLIP™) for Solar Thermal Applications at an Elevated Temperature

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Jun [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Applied Engineering and Technology; Quintana, Donald L. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Applied Engineering and Technology; Vigil, Gabrielle M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Applied Engineering and Technology; Perraglio, Martin Juan [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Applied Engineering and Technology; Farley, Cory Wayne [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Applied Engineering and Technology; Tafoya, Jose I. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Applied Engineering and Technology; Martinez, Adam L. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Applied Engineering and Technology

    2015-11-30

    The Applied Engineering and Technology-1 group (AET-1) at Los Alamos National Laboratory (LANL) conducted the proof-of-concept tests of SolarSPOT LLC’s solar thermal Temperature- Clipper, or T-CLIP™ under controlled thermal conditions using a thermal conditioning unit (TCU) and a custom made environmental chamber. The passive T-CLIP™ is a plumbing apparatus that attaches to a solar thermal collector to limit working fluid temperature and to prevent overheating, since overheating may lead to various accident scenarios. The goal of the current research was to evaluate the ability of the T-CLIP™ to control the working fluid temperature by using its passive cooling mechanism (i.e. thermosiphon, or natural circulation) in a small-scale solar thermal system. The assembled environmental chamber that is thermally controlled with the TCU allows one to simulate the various possible weather conditions, which the solar system will encounter. The performance of the T-CLIP™ was tested at two different target temperatures: 1) room temperature (70 °F) and 2) an elevated temperature (130 °F). The current test campaign demonstrated that the T-CLIP™ was able to prevent overheating by thermosiphon induced cooling in a small-scale solar thermal system. This is an important safety feature in situations where the pump is turned off due to malfunction or power outages.

  7. Game, set, match for factor VIII mismatch?

    Science.gov (United States)

    Miller, Connie H

    2015-08-13

    In this issue of Blood, Gunasekera et al provide evidence that the high rate of factor VIII (FVIII) inhibitors seen in black hemophilia A (HA) patients is not due to a mismatch between the structure of treatment products and FVIII genotypes common in blacks.

  8. Distributivity and Agreement mismatches in Serbian

    NARCIS (Netherlands)

    Bosnic, Ana

    2016-01-01

    This paper presents a truth value judgment study done on two types of numerals in the Serbian numerical system and corresponding verbal agreement mismatch that is characteristic for the numerals in question. Recent work on agreement and distributivity suggests that singular verbal marking promotes d

  9. 屋顶栽培藤本蔬菜绿化降温试验%Greening and Temperature Cooling Test for Cultivating Lianoid Vegetables on Roof

    Institute of Scientific and Technical Information of China (English)

    解盼; 龙岳林

    2014-01-01

    Roof thermal radiation is an important reason causing urban thermal environment effect, and the roof greening is an effective way to reduce the thermal radiation. This study selects the balsam pear, lentils and towel gourd as test materials and adopts box-type cultivation method on the roof with steel mesh stent to respectively observe their growth adaptability and compare their temperature cooling effect for roof. The results showed that before middle July, the growth of sponge gourd and bitter melon was vigorous, but gradually declined with increasing temperature after middle July, but lentils had strong ability to resist high temperature, so it can maintain a strong growth state until met the frost; for greening and temperature cooling effect, before middle July, there was no significant difference among three kinds of vegetable, but lentils was obviously better than sponge gourd and bitter after middle July. Cultivating lianoid vegetables on roof has significant temperature cooling effect, the higher the temperature is, the temperature cooling effect the more obvious, especially at 12:00, the temperature cooling range was the largest by 8.7℃.%屋顶热辐射是导致城市热环境效应产生的一个重要原因,屋顶绿化是减轻热辐射的一项有效措施。选用苦瓜、扁豆和丝瓜作试验材料,在屋顶上采用箱式栽培方式,搭建钢丝网作支架,分别观测其生长适应性,并比较屋面降温效果。结果表明:7月中旬前丝瓜与苦瓜生长旺盛,7月中旬后随着温度升高而逐渐衰退,而扁豆具有较强的抗高温能力,一直保持旺盛生长状态,直到遇霜枯死;绿化降温效果7月中旬之前3种蔬菜无明显差异,7月中旬以后扁豆明显优于丝瓜和苦瓜。屋顶栽培藤本蔬菜降温效果显著,气温越高降温越明显,特别是在中午12:00降温幅度最大,达到8.7℃。

  10. Thermal Test and Numerical Simulation of Nodular Cast Iron Cooling Stave%球墨铸铁冷却壁热态实验与数值模拟

    Institute of Scientific and Technical Information of China (English)

    洪军; 左海滨; 张建良; 李峰光; 沈猛; 铁金艳

    2014-01-01

    为测定消失模工艺生产的球墨铸铁冷却壁的实际冷却性能,进行1∶1热态实验.同时建立铸铁冷却壁三维稳态传热模型,模拟铸铁冷却壁的温度场分布.热态实验结果表明:该球墨铸铁冷却壁壁体与冷却水之间的综合换热系数为228W/(m2·℃),与日本新日铁第四代冷却壁相近.炉温变化对冷却壁热面温度的影响大于其对冷却壁冷面温度的影响.提高冷却水速可以降低冷却壁壁体温度,但效果不明显.模型计算结果与热态实验的比较,验证了计算模型的有效性.%To determine the actual performance of nodular cast iron stave produced by lost foam casting,the 1∶1 thermal test was carried out.The 3D steady-state heat transfer model was established to calculate the temperature field of cast iron cooling stave.Thermal test results show that the cast iron cooling stave has good cooling ability,the integrated heat transfer coefficient is 228 W/ (m2· ℃),which is close to Nippon Steel fourth-generation stave.Effect of furnace gas temperature on hot face temperature is greater than effect on cold face temperature.Increasing of cooling water velocity can lower hot face temperature,but the effect is not obvious.The comparison between computational model and thermal test verified the validity of the computational model.

  11. Ventilative Cooling

    DEFF Research Database (Denmark)

    Heiselberg, Per Kvols; Kolokotroni, Maria

    This report, by venticool, summarises the outcome of the work of the initial working phase of IEA ECB Annex 62 Ventilative Cooling and is based on the findings in the participating countries. It presents a summary of the first official Annex 62 report that describes the state-of-the-art of ventil......This report, by venticool, summarises the outcome of the work of the initial working phase of IEA ECB Annex 62 Ventilative Cooling and is based on the findings in the participating countries. It presents a summary of the first official Annex 62 report that describes the state...

  12. DnaN clamp zones provide a platform for spatiotemporal coupling of mismatch detection to DNA replication.

    Science.gov (United States)

    Lenhart, Justin S; Sharma, Anushi; Hingorani, Manju M; Simmons, Lyle A

    2013-02-01

    Mismatch repair (MMR) increases the fidelity of DNA replication by identifying and correcting replication errors. Processivity clamps are vital components of DNA replication and MMR, yet the mechanism and extent to which they participate in MMR remains unclear. We investigated the role of the Bacillus subtilis processivity clamp DnaN, and found that it serves as a platform for mismatch detection and coupling of repair to DNA replication. By visualizing functional MutS fluorescent fusions in vivo, we find that MutS forms foci independent of mismatch detection at sites of replication (i.e. the replisome). These MutS foci are directed to the replisome by DnaN clamp zones that aid mismatch detection by targeting the search to nascent DNA. Following mismatch detection, MutS disengages from the replisome, facilitating repair. We tested the functional importance of DnaN-mediated mismatch detection for MMR, and found that it accounts for 90% of repair. This high dependence on DnaN can be bypassed by increasing MutS concentration within the cell, indicating a secondary mode of detection in vivo whereby MutS directly finds mismatches without associating with the replisome. Overall, our results provide new insight into the mechanism by which DnaN couples mismatch recognition to DNA replication in living cells.

  13. Advanced Cooling Technology Development Program (ACTD). Tests Results from AEDC Track G Tests of Aerojet TCNTs Using Propylene Glycol Analysis Report. (Final)

    Science.gov (United States)

    1983-03-01

    Changes, Test 5751 37 14 Test 5749 and 5751 Thermal Test Data Comparison with Code Predictions 38 15 Test 5768 Thermal Test Data Comparison with Code...observed recession. [lowever, the thermal test data in this region was obscured by flare from the model holder. On test 5768 the measured...ray photographs, and image converter camera thermal plots. As was mentioned previously the thermal test data is somewhat distorted due to model flare

  14. Cool snacks

    DEFF Research Database (Denmark)

    Grunert, Klaus G; Brock, Steen; Brunsø, Karen

    2016-01-01

    such a product requires an interdisciplinary effort where researchers with backgrounds in psychology, anthropology, media science, philosophy, sensory science and food science join forces. We present the COOL SNACKS project, where such a blend of competences was used first to obtain thorough insight into young...

  15. On the Safety and Performance Demonstration Tests of Prototype Gen-IV Sodium-Cooled Fast Reactor and Validation and Verification of Computational Codes

    Directory of Open Access Journals (Sweden)

    Jong-Bum Kim

    2016-10-01

    Full Text Available The design of Prototype Gen-IV Sodium-Cooled Fast Reactor (PGSFR has been developed and the validation and verification (V&V activities to demonstrate the system performance and safety are in progress. In this paper, the current status of test activities is described briefly and significant results are discussed. The large-scale sodium thermal-hydraulic test program, Sodium Test Loop for Safety Simulation and Assessment-1 (STELLA-1, produced satisfactory results, which were used for the computer codes V&V, and the performance test results of the model pump in sodium showed good agreement with those in water. The second phase of the STELLA program with the integral effect tests facility, STELLA-2, is in the detailed design stage of the design process. The sodium thermal-hydraulic experiment loop for finned-tube sodium-to-air heat exchanger performance test, the intermediate heat exchanger test facility, and the test facility for the reactor flow distribution are underway. Flow characteristics test in subchannels of a wire-wrapped rod bundle has been carried out for safety analysis in the core and the dynamic characteristic test of upper internal structure has been performed for the seismic analysis model for the PGSFR. The performance tests for control rod assemblies (CRAs have been conducted for control rod drive mechanism driving parts and drop tests of the CRA under scram condition were performed. Finally, three types of inspection sensors under development for the safe operation of the PGSFR were explained with significant results.

  16. Circuit mismatch influence on performance of paralleling silicon carbide MOSFETs

    DEFF Research Database (Denmark)

    Li, Helong; Munk-Nielsen, Stig; Pham, Cam

    2014-01-01

    This paper focuses on circuit mismatch influence on performance of paralleling SiC MOSFETs. Power circuit mismatch and gate driver mismatch influences are analyzed in detail. Simulation and experiment results show the influence of circuit mismatch and verify the analysis. This paper aims to give...... suggestions on paralleling discrete SiC MOSFETs and designing layout of power modules with paralleled SiC MOSFETs dies....

  17. Stochastic cooling

    Energy Technology Data Exchange (ETDEWEB)

    Bisognano, J.; Leemann, C.

    1982-03-01

    Stochastic cooling is the damping of betatron oscillations and momentum spread of a particle beam by a feedback system. In its simplest form, a pickup electrode detects the transverse positions or momenta of particles in a storage ring, and the signal produced is amplified and applied downstream to a kicker. The time delay of the cable and electronics is designed to match the transit time of particles along the arc of the storage ring between the pickup and kicker so that an individual particle receives the amplified version of the signal it produced at the pick-up. If there were only a single particle in the ring, it is obvious that betatron oscillations and momentum offset could be damped. However, in addition to its own signal, a particle receives signals from other beam particles. In the limit of an infinite number of particles, no damping could be achieved; we have Liouville's theorem with constant density of the phase space fluid. For a finite, albeit large number of particles, there remains a residue of the single particle damping which is of practical use in accumulating low phase space density beams of particles such as antiprotons. It was the realization of this fact that led to the invention of stochastic cooling by S. van der Meer in 1968. Since its conception, stochastic cooling has been the subject of much theoretical and experimental work. The earliest experiments were performed at the ISR in 1974, with the subsequent ICE studies firmly establishing the stochastic cooling technique. This work directly led to the design and construction of the Antiproton Accumulator at CERN and the beginnings of p anti p colliding beam physics at the SPS. Experiments in stochastic cooling have been performed at Fermilab in collaboration with LBL, and a design is currently under development for a anti p accumulator for the Tevatron.

  18. Design of Refractory Metal Heat Pipe Life Test Environment Chamber, Cooling System, and Radio Frequency Heating System

    Science.gov (United States)

    Martin, J. J.; Bragg-Sitton, S. M.; Reid, R. S.; Stewart, E. T.; Davis, J. D.

    2011-01-01

    A series of 16 Mo-44.5%Re alloy/sodium heat pipes will be experimentally tested to examine heat pipe aging. To support this evaluation, an environmental test chamber and a number of auxiliary subsystems are required. These subsystems include radio frequency (RF) power supplies/inductive coils, recirculation water coolant loops, and chamber gas conditioning. The heat pipes will be grouped, based on like power and gas mixture requirements, into three clusters of five units each, configured in a pentagonal arrangement. The highest powered heat pipe will be tested separately. Test chamber atmospheric purity is targeted at test hardware, providing warning indicators followed by automatic shutdown should potentially damaging conditions develop. During hardware construction, a number of checkout tests.many making use of stainless steel prototype heat pipes that are already fabricated.will be required to verify operation.

  19. Long term out-of-pile thermocouple tests in conditions representative for nuclear gas-cooled high temperature reactors

    OpenAIRE

    LAURIE Mathias; FOURREZ Stéphane; FUETTERER Michael; LAPETITE Jean-Marc; SADLI M.; MORICE Ronan; FAILLEAU G

    2013-01-01

    During irradiation tests at high temperature failure of commercial Inconel 600 sheathed thermocouples is commonly encountered. As instrumentation, in particular thermocouples are considered safety-relevant both for irradiation tests and for commercial reactors, JRC and THERMOCOAX joined forces to solve this issue by performing out-of-pile tests with thermocouples mimicking the environment encountered by high temperature reactor (HTR) in-core instrumentation. The objective was to screen innova...

  20. Long Term Out-of-pile Thermocouple Tests in Conditions Representative for Nuclear Gas-cooled High Temperature Reactors

    OpenAIRE

    LAURIE Mathias; FOURREZ Stephane; FUETTERER Michael; LAPETITE Jean-Marc

    2011-01-01

    During irradiation tests at high temperature, failure of commercial Inconel 600 sheathed thermocouples is commonly encountered. To understand and remediate this problem, out-ofpile tests were performed with thermocouples in carburizing atmospheres which can be assumed to be at least locally representative for High Temperature Reactors. The objective was to screen those thermocouples which would consecutively be used under irradiation. Two such screening tests have been performed with a set of...

  1. Long term out-of-pile thermocouple tests in conditions representative for nuclear gas-cooled high temperature reactors

    Energy Technology Data Exchange (ETDEWEB)

    Laurie, M., E-mail: mathias.laurie@ec.europa.eu [European Commission, Joint Research Centre, Institut für Transurane, Hermann-von-Helmholtz-Platz 1, 76344, Eggenstein-Leopoldshafen (Germany); Fourrez, S. [THERMOCOAX SAS, Rue du Pré Neuf, 61100 Saint Georges des Groseillers (France); Fütterer, M.A.; Lapetite, J.M. [European Commission, Joint Research Centre, Institut für Transurane, Hermann-von-Helmholtz-Platz 1, 76344, Eggenstein-Leopoldshafen (Germany); Sadli, M.; Morice, R.; Failleau, G. [Laboratoire commun de métrologie LNE-Cnam, 61 rue du Landy, F-92310 Saint-Denis (France)

    2014-05-01

    During irradiation tests at high temperature failure of commercial Inconel 600 sheathed thermocouples is commonly encountered. As instrumentation, in particular thermocouples are considered safety-relevant both for irradiation tests and for commercial reactors, JRC and THERMOCOAX joined forces to solve this issue by performing out-of-pile tests with thermocouples mimicking the environment encountered by high temperature reactor (HTR) in-core instrumentation. The objective was to screen innovative sheathed thermocouples which would consecutively be tested under irradiation. Two such screening tests have been performed in high temperature environment (i.e. temperature in the range 1100–1150 °C) with purposely contaminated helium atmosphere (mainly CH{sub 4}, CO, CO{sub 2}, O{sub 2} impurities) representative for high temperature reactor carburizing atmospheres. The first set of thermocouples embedded in graphite (mainly conventional N type thermocouples and thermocouples with innovative sheaths) was tested in a dedicated furnace at THERMOCOAX lab with helium flushing. The second out-of-pile test at JRC with a partly different set of thermocouples replicated the original test for comparison. Performance indicators such as thermal drift, insulation resistance and loop resistance were monitored. Through these long-term screening tests the effect of several parameters were investigated: niobium sleeves, bending, diameter, sheath composition as well as the chemical environment. SEM examinations were performed to analyze local damage (bending zone, sheath). The present paper describes the two tests, sums up data collected during these tests in terms of thermocouple behavior and describes further instrumentation testing work with fixed point mini cells for qualification under irradiation.

  2. Skill mismatch and use in developed countries: Evidence from the PIAAC study

    NARCIS (Netherlands)

    Allen, J.P.; Levels, M.; van der Velden, R.K.W.

    2013-01-01

    In this paper we develop and test a new set of measures of skill mismatches, based on data on skill levels and skill use in the domains of literacy and numeracy from the PIAAC project. The measures we develop represent the extent of skill use relative to one’s own skill level. We test the measures b

  3. Cooling Performance of an Impingement Cooling Device Combined with Pins

    Institute of Scientific and Technical Information of China (English)

    Dongliang QUAN; Songling LIU; Jianghai LI; Gaowen LIU

    2005-01-01

    Experimental study and one dimensional model analysis were conducted to investigate cooling performance of an integrated impingement and pin fin cooling device. A typical configuration specimen was made and tested in a large scale low speed closed-looped wind tunnel. Detailed two-dimensional contour maps of the temperature and cooling effectiveness were obtained for different pressure ratios and therefore different coolant flow-rates through the tested specimen. The experimental results showed that very high cooling effectiveness can be achieved by this cooling device with relatively small amount of coolant flow. Based on the theory of transpiration cooling in porous material, a one dimensional heat transfer model was established to analyze the effect of various parameters on cooling effectiveness. It was found from this model that the variation of heat transfer on the gas side, including heat transfer coefficient and film cooling effectiveness, of the specimen created much more effect on its cooling effectiveness than that of the coolant side. The predictions of the one-dimensional mode were compared and agreed well with the experimental data.

  4. Architectural mismatch issues in identity management deployment

    DEFF Research Database (Denmark)

    Andersen, Mads Schaarup

    2010-01-01

    Integrating Commercial Off-The-Shelf products in a company's software product portfolio offers business value, but introduces challenges from a software architecture perspective. In this paper, the research challenges in relation to identity management in the Danish municipality administration...... system called Opus, are outlined. Opus BRS is the identity management part of Opus. Opus integrates SAP, legacy mainframe systems, and other third party systems of the individual municipality. Each of these systems define their own software architecture and access control model, leading to architectural...... mismatch with an impact on security, usability, and maintainability. The research project is discussed and access control and identity provisioning are recognized as the major areas of interest in relation to the mismatch challenges. The project is carried out in close cooperation with KMD, one...

  5. Mechanisms and functions of DNA mismatch repair

    Institute of Scientific and Technical Information of China (English)

    Guo MinLi

    2008-01-01

    DNA mismatch repair (MMR) is a highly conserved biological pathway that plays a key role in maintaining genomic stability. The specificity of MMR is primarily for base-base mismatches and insertion/deletion mispairs generated dur-ing DNA replication and recombination. MMR also suppresses homeologous recombination and was recently shown to play a role in DNA damage signaling in eukaryotic cells. Escherichia coli MutS and MutL and their eukaryotic homo-logs, MutSα and MutLα, respectively, are key players in MMR-associated genome maintenance. Many other protein components that participate in various DNA metabolic pathways, such as PCNA and RPA, are also essential for MMR. Defects in MMR are associated with genome-wide instability, predisposition to certain types of cancer including he-reditary non-polyposis colorectal cancer, resistance to certain chemotherapeutic agents, and abnormalities in meiosis and sterility in mammalian systems.

  6. A very cool cooling system

    CERN Multimedia

    Antonella Del Rosso

    2015-01-01

    The NA62 Gigatracker is a jewel of technology: its sensor, which delivers the time of the crossing particles with a precision of less than 200 picoseconds (better than similar LHC detectors), has a cooling system that might become the precursor to a completely new detector technique.   The 115 metre long vacuum tank of the NA62 experiment. The NA62 Gigatracker (GTK) is composed of a set of three innovative silicon pixel detectors, whose job is to measure the arrival time and the position of the incoming beam particles. Installed in the heart of the NA62 detector, the silicon sensors are cooled down (to about -20 degrees Celsius) by a microfluidic silicon device. “The cooling system is needed to remove the heat produced by the readout chips the silicon sensor is bonded to,” explains Alessandro Mapelli, microsystems engineer working in the Physics department. “For the NA62 Gigatracker we have designed a cooling plate on top of which both the silicon sensor and the...

  7. Development and Testing of Cool-Season Grass Species, Varieties and Hybrids for Biomass Feedstock Production in Western North America

    Directory of Open Access Journals (Sweden)

    Steven R. Larson

    2017-01-01

    Full Text Available Breeding of native cool-season grasses has the potential to improve forage production and expand the range of bioenergy feedstocks throughout western North America. Basin wildrye (Leymus cinereus and creeping wildrye (Leymus triticoides rank among the tallest and most rhizomatous grasses of this region, respectively. The objectives of this study were to develop interspecific creeping wildrye (CWR × basin wildrye (BWR hybrids and evaluate their biomass yield relative to tetraploid ‘Trailhead’, octoploid ‘Magnar’ and interploidy-hybrid ‘Continental’ BWR cultivars in comparison with other perennial grasses across diverse single-harvest dryland range sites and a two-harvest irrigated production system. Two half-sib hybrid populations were produced by harvesting seed from the tetraploid self-incompatible Acc:641.T CWR genet, which was clonally propagated by rhizomes into isolated hybridization blocks with two tetraploid BWR pollen parents: Acc:636 and ‘Trailhead’. Full-sib hybrid seed was also produced from a controlled cross of tetraploid ‘Rio’ CWR and ‘Trailhead’ BWR plants. In space-planted range plots, the ‘Rio’ CWR × ‘Trailhead’ BWR and Acc:641.T CWR × Acc:636 BWR hybrids displayed high-parent heterosis with 75% and 36% yield advantages, respectively, but the Acc:641.T CWR × ‘Trailhead’ BWR hybrid yielded significantly less than its BWR high-parent in this evaluation. Half-sib CWR × BWR hybrids of Acc:636 and ‘Trailhead’ both yielded as good as or better than available BWR cultivars, with yields similar to switchgrass (Panicum virgatum, in the irrigated sward plots. These results elucidate opportunity to harness genetic variation among native grass species for the development of forage and bioenergy feedstocks in western North America.

  8. Effects of Mismatched Parameter on Chaotic Synchronization

    Institute of Scientific and Technical Information of China (English)

    PENGJiang-hua; FANGJin-qing

    2003-01-01

    Chaos-based security communication has become one of the most interesting hot subjects for research of chaotic theory in real world since. In recent years, secure communication via synchronized chaos has been intensely studied. However, in practical application it is difficult to construct two complete identical chaotic systems since there are many reasons to induce parameter mismatch between two systems (response system and drive system).

  9. Skill mismatch and overeducation in transition economies

    OpenAIRE

    Kupets, Olga

    2015-01-01

    Large imbalances between the supply and demand for skills in transition economies are driven by rapid economic restructuring, misalignment of the education system with labor market needs, and underdeveloped adult education and training systems. The costs of mismatches can be large and long-lasting for workers, firms, and economies, with long periods of overeducation implying a loss of human capital for individuals and ineffective use of resources for the economy. To make informed decisions, p...

  10. Prediction calculations and experiments for the first criticality of the 10 MW High Temperature Gas-cooled Reactor-Test Module

    Energy Technology Data Exchange (ETDEWEB)

    Jing Xingqing E-mail: jingxq@d103.inet.tsinghua.edu.cn; Xu Xiaolin; Yang Yongwei; Qu Ronghong

    2002-10-01

    The 10 MW High Temperature Gas-cooled Reactor-Test Module (HTR-10) is a pebble bed experimental reactor built by the Institute of Nuclear Energy Technology (INET), Tsinghua University. This paper introduces the first critical prediction calculations and the experiments for the HTR-10. The German VSOP neutronics code is used for the prediction calculations of the first loading. The characteristics of pebble-bed high temperature gas-cooled reactors are taken into account, including the double heterogeneity of the fuel element, the buckling feedback of the spectrum calculation, the effect of the mixture of fuel elements and graphite balls, and the correction of the diffusion coefficients in the upper cavity based on transport theory. Also considered are the effects of impurities in the fuel elements, in the graphite balls and in the reflector graphite on the reactivity. The number of fuel elements and graphite balls in the initial core is predicted to provide reference for the first criticality experiment. The critical experiment adopts a method of extrapolating to approach criticality. The first criticality was attained on December 1, 2000. The first criticality experiment shows that the predicted critical number of the fuel elements and graphite balls is in close agreement with the experimental results. Their relative error is less than 1.0%, implying the physical predictions and the results of the criticality experiment are much beyond expectations.

  11. Simulation of the passive condensation cooling tank of the PASCAL test facility using the component thermal-hydraulic analysis code CUPID

    Energy Technology Data Exchange (ETDEWEB)

    Cho, H. K.; Lee, S. J.; Kang, K. H.; Yoon, H. Y. [Korea Atomic Energy Research Inst., 1045 Daeduk-daero, Daejeon (Korea, Republic of)

    2012-07-01

    For the analysis of transient two-phase flows in nuclear reactor components, a three-dimensional thermal hydraulics code, named CUPID, has been being developed. In the present study, the CUPID code was applied for the simulation of the PASCAL (PAFS Condensing Heat Removal Assessment Loop) test facility constructed with an aim of validating the cooling and operational performance of the PAFS (Passive Auxiliary Feedwater System). The PAFS is one of the advanced safety features adopted in the APR+ (Advanced Power Reactor +), which is intended to completely replace the conventional active auxiliary feedwater system. This paper presents the preliminary simulation results of the PASCAL facility performed with the CUPID code in order to verify its applicability to the thermal-hydraulic phenomena inside the system. A standalone calculation for the passive condensation cooling tank was performed by imposing a heat source boundary condition and the transient thermal-hydraulic behaviors inside the system, such as the water level, temperature and velocity, were qualitatively investigated. The simulation results verified that the natural circulation and boiling phenomena in the water pool can be well reproduced by the CUPID code. (authors)

  12. Lawrence Livermore National Laboratory (LLNL) Experimental Test Site (Site 300) Salinity Evaluation and Minimization Plan for Cooling Towers and Mechanical Equipment Discharges

    Energy Technology Data Exchange (ETDEWEB)

    Daily III, W D

    2010-02-24

    This document was created to comply with the Central Valley Regional Water Quality Control Board (CVRWQCB) Waste Discharge Requirement (Order No. 98-148). This order established new requirements to assess the effect of and effort required to reduce salts in process water discharged to the subsurface. This includes the review of technical, operational, and management options available to reduce total dissolved solids (TDS) concentrations in cooling tower and mechanical equipment water discharges at Lawrence Livermore National Laboratory's (LLNL's) Experimental Test Site (Site 300) facility. It was observed that for the six cooling towers currently in operation, the total volume of groundwater used as make up water is about 27 gallons per minute and the discharge to the subsurface via percolation pits is 13 gallons per minute. The extracted groundwater has a TDS concentration of 700 mg/L. The cooling tower discharge concentrations range from 700 to 1,400 mg/L. There is also a small volume of mechanical equipment effluent being discharged to percolation pits, with a TDS range from 400 to 3,300 mg/L. The cooling towers and mechanical equipment are maintained and operated in a satisfactory manner. No major leaks were identified. Currently, there are no re-use options being employed. Several approaches known to reduce the blow down flow rate and/or TDS concentration being discharged to the percolation pits and septic systems were reviewed for technical feasibility and cost efficiency. These options range from efforts as simple as eliminating leaks to implementing advanced and innovative treatment methods. The various options considered, and their anticipated effect on water consumption, discharge volumes, and reduced concentrations are listed and compared in this report. Based on the assessment, it was recommended that there is enough variability in equipment usage, chemistry, flow rate, and discharge configurations that each discharge location at Site 300

  13. Measurement of transmission efficiency for 400 MeV proton beam through collimator at Fermilab MuCool Test Area using Chromox-6 scintillation screen.

    Science.gov (United States)

    Jana, M R; Chung, M; Freemire, B; Hanlet, P; Leonova, M; Moretti, A; Palmer, M; Schwarz, T; Tollestrup, A; Torun, Y; Yonehara, K

    2013-06-01

    The MuCool Test Area (MTA) at Fermilab is a facility to develop the technology required for ionization cooling for a future Muon Collider and∕or Neutrino Factory. As part of this research program, feasibility studies of various types of RF cavities in a high magnetic field environment are in progress. As a unique approach, we have tested a RF cavity filled with a high pressure hydrogen gas with a 400 MeV proton beam in an external magnetic field (B = 3 T). Quantitative information about the number of protons passing through this cavity is an essential requirement of the beam test. The MTA is a flammable gas (hydrogen) hazard zone. Due to safety reasons, no active (energized) beam diagnostic instrument can be used. Moreover, when the magnetic field is on, current transformers (toroids) used for beam intensity measurements do not work due to the saturation of the ferrite material of the transformer. Based on these requirements, we have developed a passive beam diagnostic instrumentation using a combination of a Chromox-6 scintillation screen and CCD camera. This paper describes details of the beam profile and position obtained from the CCD image with B = 0 T and B = 3 T, and for high and low intensity proton beams. A comparison is made with beam size obtained from multi-wires detector. Beam transmission efficiency through a collimator with a 4 mm diameter hole is measured by the toroids and CCD image of the scintillation screen. Results show that the transmission efficiency estimated from the CCD image is consistent with the toroid measurement, which enables us to monitor the beam transmission efficiency even in a high magnetic field environment.

  14. Cooling technique

    Energy Technology Data Exchange (ETDEWEB)

    Salamon, Todd R; Vyas, Brijesh; Kota, Krishna; Simon, Elina

    2017-01-31

    An apparatus and a method are provided. Use is made of a wick structure configured to receive a liquid and generate vapor in when such wick structure is heated by heat transferred from heat sources to be cooled off. A vapor channel is provided configured to receive the vapor generated and direct said vapor away from the wick structure. In some embodiments, heat conductors are used to transfer the heat from the heat sources to the liquid in the wick structure.

  15. Rapid cooled lens cell

    Science.gov (United States)

    Stubbs, David M.; Hsu, Ike C.

    1991-12-01

    This paper describes the optomechanical design, thermal analysis, fabrication, and test evaluation processes followed in developing a rapid cooled, infrared lens cell. Thermal analysis was the key engineering discipline exercised in the design phase. The effect of thermal stress on the lens, induced by rapid cooling of the lens cell, was investigated. Features of this lens cell that minimized the thermal stress will be discussed in a dedicated section. The results of thermal analysis on the selected lens cell design and the selection of the flow channel design in the heat exchanger will be discussed. Throughout the paper engineering drawings, illustrations, analytical results, and photographs of actual hardware are presented.

  16. The Eukaryotic Mismatch Recognition Complexes Track with the Replisome during DNA Synthesis.

    Directory of Open Access Journals (Sweden)

    Joanna E Haye

    2015-12-01

    Full Text Available During replication, mismatch repair proteins recognize and repair mispaired bases that escape the proofreading activity of DNA polymerase. In this work, we tested the model that the eukaryotic mismatch recognition complex tracks with the advancing replisome. Using yeast, we examined the dynamics during replication of the leading strand polymerase Polε using Pol2 and the eukaryotic mismatch recognition complex using Msh2, the invariant protein involved in mismatch recognition. Specifically, we synchronized cells and processed samples using chromatin immunoprecipitation combined with custom DNA tiling arrays (ChIP-chip. The Polε signal was not detectable in G1, but was observed at active origins and replicating DNA throughout S-phase. The Polε signal provided the resolution to track origin firing timing and efficiencies as well as replisome progression rates. By detecting Polε and Msh2 dynamics within the same strain, we established that the mismatch recognition complex binds origins and spreads to adjacent regions with the replisome. In mismatch repair defective PCNA mutants, we observed that Msh2 binds to regions of replicating DNA, but the distribution and dynamics are altered, suggesting that PCNA is not the sole determinant for the mismatch recognition complex association with replicating regions, but may influence the dynamics of movement. Using biochemical and genomic methods, we provide evidence that both MutS complexes are in the vicinity of the replisome to efficiently repair the entire spectrum of mutations during replication. Our data supports the model that the proximity of MutSα/β to the replisome for the efficient repair of the newly synthesized strand before chromatin reassembles.

  17. MutS recognition: Multiple mismatches and sequence context effects

    Indian Academy of Sciences (India)

    Amita Joshi; Basuthkar J Rao

    2001-12-01

    Escherichia coli MutS is a versatile repair protein that specifically recognizes not only various types of mismatches but also single stranded loops of up to 4 nucleotides in length. Specific binding, followed by the next step of tracking the DNA helix that locates hemi-methylated sites, is regulated by the conformational state of the protein as a function of ATP binding/hydrolysis. Here, we study how various molecular determinants of a heteroduplex regulate mismatch recognition by MutS, the critical first step of mismatch repair. Using classical DNase I footprinting assays, we demonstrate that the hierarchy of MutS binding to various types of mismatches is identical whether the mismatches are present singly or in multiples. Moreover, this unique hierarchy is indifferent both to the differential level of DNA helical flexibility and to the unpaired status of the mismatched bases in a heteroduplex. Surprisingly, multiple mismatches exhibit reduced affinity of binding to MutS, compared to that of a similar single mismatch. Such a reduction in the affinity might be due to sequence context effects, which we established more directly by studying two identical single mismatches in an altered sequence background. A mismatch, upon simply being flipped at the same location, elicits changes in MutS specific contacts, thereby underscoring the importance of sequence context in modulating MutS binding to mismatches.

  18. Eukaryotic Mismatch Repair in Relation to DNA Replication.

    Science.gov (United States)

    Kunkel, Thomas A; Erie, Dorothy A

    2015-01-01

    Three processes act in series to accurately replicate the eukaryotic nuclear genome. The major replicative DNA polymerases strongly prevent mismatch formation, occasional mismatches that do form are proofread during replication, and rare mismatches that escape proofreading are corrected by mismatch repair (MMR). This review focuses on MMR in light of increasing knowledge about nuclear DNA replication enzymology and the rate and specificity with which mismatches are generated during leading- and lagging-strand replication. We consider differences in MMR efficiency in relation to mismatch recognition, signaling to direct MMR to the nascent strand, mismatch removal, and the timing of MMR. These studies are refining our understanding of relationships between generating and repairing replication errors to achieve accurate replication of both DNA strands of the nuclear genome.

  19. SU-C-213-07: Fabrication and Testing of a 3D-Printed Small Animal Rectal Cooling Device to Evaluate Local Hypothermia as a Radioprotector During Prostate SBRT

    Energy Technology Data Exchange (ETDEWEB)

    Hrycushko, B; Chopra, R; Futch, C; Bing, C; Wodzak, M; Stojadinovic, S; Jiang, S; Medin, P [UT Southwestern Medical Center, Dallas, TX (United States)

    2015-06-15

    Purpose: The protective effects of induced or even accidental hypothermia on the human body are widespread with several medical uses currently under active research. In vitro experiments using human cell lines have shown hypothermia provides a radioprotective effect that becomes more pronounced at large, single-fraction doses common to SBRT treatments. Relevant to prostate SBRT, this work details the fabrication and testing of a 3D-printed cooling device to facilitate the investigation of the radioprotective effect of local hypothermia on the rat rectum. Methods: A 3cm long, two-channel rectal cooling device was designed in SOLIDWORKS CAD for 3D printing. The water intake nozzle is connected to a 1mm diameter brass pipe from which water flows and circulates back around to the exit nozzle. Both nozzles are connected by plastic tubing to a water chiller pump. Following leak-proof testing, fiber optic temperature probes were used to evaluate the temperature over time when placed adjacent to the cooling device within a rat rectum. MRI thermometry characterized the relative temperature distribution in concentric ROIs surrounding the probe. CBCT images from a small-animal irradiator were evaluated for imaging artifacts which could affect Monte Carlo dose calculations during treatment planning. Results: The rectal temperature adjacent to the cooling device decreased from body temperature (37°C) to 15°C in 10–20 minutes from device insertion. Rectal temperature was maintained at 15±3°C during active cooling. MRI thermometry tests revealed a steep temperature gradient with increasing distance from the cooling device, with the desired temperature range maintained within the surrounding few millimeters. Conclusion: A 3D printed rectal cooling device was fabricated for the purpose of inducing local hypothermia in rat rectums. Rectal cooling capabilities were characterized in-vivo to facilitate an investigation of the radioprotective effect of hypothermia for late rectal

  20. Test of a cryogenic set-up for a 10 meter long liquid nitrogen cooled superconducting power cable

    DEFF Research Database (Denmark)

    Træholt, Chresten; Rasmussen, Carsten; Kühle (fratrådt), Anders Van Der Aa

    2000-01-01

    cable. We report on our experimental set-up for testing a 10 meter long high temperature superconducting cable with a critical current of 3.2 kA at 77K. The set-up consists of a custom designed cable end termination, current lead, coolant feed-through, liquid nitrogen closed loop circulation system...

  1. Long term out-of-pile thermocouple tests in conditions representative for nuclear gas-cooled high temperature reactors

    Energy Technology Data Exchange (ETDEWEB)

    Laurie, M. [European Commission, Joint Research Centre, Inst. for Energy, P.O. Box 2, NL-1755 ZG Petten (Netherlands); Fourrez, S. [THERMOCOAX SAS, BP 26, Planquivon, F-61438 Flers Cedex (France); Fuetterer, M. A.; Lapetite, J. M. [European Commission, Joint Research Centre, Inst. for Energy, P.O. Box 2, NL-1755 ZG Petten (Netherlands)

    2011-07-01

    During irradiation tests at high temperature, failure of commercial Inconel 600 sheathed thermocouples is commonly encountered. To understand and remedy this problem, out-of-pile tests were performed with thermocouples in carburizing atmospheres which can be assumed to be at least locally representative for High Temperature Reactors. The objective was to screen those thermocouples which would consecutively be used under irradiation. Two such screening tests have been performed with a set of thermocouples embedded in graphite (mainly conventional Type N thermocouples and thermocouples with innovative sheaths) in a dedicated furnace with helium flushing. Performance indicators such as thermal drift, insulation and loop resistance were monitored and compared to those from conventional Type N thermocouples. Several parameters were investigated: niobium sleeves, bending, thickness, sheath composition, temperature as well as the chemical environment. After the tests, Scanning Electron Microscopy (SEM) examinations were performed to analyze possible local damage in wires and in the sheath. The present paper describes the two experiments, summarizes results and outlines further work, in particular to further analyze the findings and to select suitable thermocouples for qualification under irradiation. (authors)

  2. Development and testing of thermal energy storage modules for use in active solar heating and cooling systems

    Science.gov (United States)

    Parker, J. C.

    1981-04-01

    The project development requirements and criteria are presented along with technical data for the modules. Performance tests included: ducting, temperature, pressure and air flow measurements, dry and wet bulb temperature; duct pressure measurements; and air conditioning apparatus checks; installation, operation, and maintenance instructions are included.

  3. Model-based control of a fuel cell cooling circuit with automatic software testing; Modellbasierte Steuerung des Kuehlkreislaufes einer Brennstoffzelle mit automatisiertem Test der Software

    Energy Technology Data Exchange (ETDEWEB)

    Schaefer, Sascha

    2012-07-01

    For reconstruction and control of the volume flow in a cooling circuit a fuel cell system is analyzed, and physical models of the fluid temperature and pump volume flow are derived. On this basis, functional models for derivation of software algorithms are presented which enable model-based calculation of the volume flow in a fluid circuit and coolant pump control on the basis of detailed system modelling. The available functions enable complete control and diagnosis of the volume flow. The functional models in Matlab/Simulink will be implemented in a control unit; they are discussed in the context of a software development process. It is stressed that correctness of the functions must be assured, and a trial automation system for functional models of this type is presented. (orig./AKB) [German] Zur Rekonstruktion und Steuerung des Volumenstroms in einem Kuehlkreislauf, wird ein Brennstoffzellensystem analysiert und physikalische Modelle fuer die Fluidtemperatur und den Pumpenvolumenstrom werden hergeleitet. Basierend auf diesen Zusammenhaengen werden Funktionsmodelle zur Ableitung von Softwarealgorithmen vorgestellt. Diese ermoeglichen es den Volumenstrom in einem Fluidkreislauf modellbasiert zu bestimmen bzw. die Kuehlmittelpumpe basierend auf einer detaillierten Systemmodellierung zu steuern. Die zur Verfuegung stehenden Funktionen erlauben eine komplette Regelung, Steuerung und Diagnose des Volumenstroms. Die Funktionsmodelle, in Matlab/Simulink realisiert und zur Ausfuehrung auf einem Steuergeraet vorgesehen, werden im Kontext eines Softwareentwicklungsprozesses diskutiert. Es wird die Notwendigkeit der Sicherstellung der Korrektheit der Funktionen herausgearbeitet und ein Testautomatisierungssystem fuer solche Funktionsmodelle vorgestellt.

  4. Understanding the Mismatch Between Coaches' and Players' Perceptions of Exertion.

    Science.gov (United States)

    Brink, Michel S; Kersten, Anna W; Frencken, Wouter G P

    2017-04-01

    A mismatch between the training exertion intended by a coach and the exertion perceived by players is well established in sports. However, it is unknown whether coaches can accurately observe exertion of individual players during training. Furthermore, the discrepancy in coaches' and players' perceptions has not been explained. To determine the relation between intended and observed training exertion by the coach and perceived training exertion by the players and establish whether on-field training characteristics, intermittent endurance capacity, and maturity status explain the mismatch. During 2 mesocycles of 4 wk (in November and March), rating of intended exertion (RIE), rating of observed exertion (ROE), and rating of perceived exertion (RPE) were monitored in 31 elite young soccer players. External and internal training loads were objectively quantified with accelerometers (PlayerLoad) and heart-rate monitors (TRIMPmod). Results of an interval shuttle-run test (ISRT) and age at peak height velocity (APHV) were determined for all players. RIE, ROE, and RPE were monitored in 977 training sessions. The correlations between RIE and RPE (r = .58; P players will do and what they actually did on the field. When doing this, they consider the intermittent endurance capacity of individual players.

  5. Random test of R22 and HFC leakage in cooling installations; Steekproefonderzoek R22 en HFK lekkage koelinstallaties

    Energy Technology Data Exchange (ETDEWEB)

    Pennartz, F.; Van den Bovenkamp, M. [KWA Bedrijfsadviseurs, Amersfoort (Netherlands)

    2013-02-15

    KWA Business Consultants has conducted a random test survey in the dairy industry, meat industry and a peer group in other food sectors. The main goal was to obtain data on the size and trends of R22 and HFC emissions in the period 2007-2010. The survey is carried out by collecting the data of refilling refrigeration installations that have been registered by the refrigeration contractors. In total 1984 installations of 193 companies participated in the random test [Dutch] Begin 2012 is in opdracht van Agentschap NL onderzoek uitgevoerd naar lekkages van R22 en HFK koudemiddelen uit koelinstallaties in de sectoren zuivel, vlees en overige gerelateerde sectoren in de voedingsmiddelenindustrie. Het onderzoek had de vorm van een steekproef. Er hebben 193 bedrijven deelgenomen; 1984 koelinstallaties zijn onderzocht. Het gemiddelde lekpercentages is 7. De lekkages zijn afkomstig van 10 procent van de installaties uit de onderzoeksgroep.

  6. Design validation of an air cooled turbo generator by using fibre optic sensors in a shop test

    Science.gov (United States)

    Bosselmann, T.; Willsch, M.; Villnow, M.; Strack, S.; Chernogorski, V.; Weidner, J. R.; Roeding, R.; Schwanengel, U.; Trefflich, L.; Lindholm, S.; Abromitis, E.

    2012-06-01

    The increasing need of energy and the increasing share of renewables in electric power generation demands higher flexibility in the operation of conventional power plants. Turbo generators have to face higher stress during operation without consuming additional life time. For the first time in a shop test a new generator design was extensively evaluated by using about 250 fibre optic sensors - mostly new developed - to control temperature, strain, movement and vibration.

  7. ATLAS - Liquid Cooling Systems

    CERN Multimedia

    Bonneau, P.

    1998-01-01

    Photo 1 - Cooling Unit - Side View Photo 2 - Cooling Unit - Detail Manifolds Photo 3 - Cooling Unit - Rear View Photo 4 - Cooling Unit - Detail Pump, Heater and Exchanger Photo 5 - Cooling Unit - Detail Pump and Fridge Photo 6 - Cooling Unit - Front View

  8. Daytime Locations in Spatial Mismatch: Job Accessibility and Employment at Reentry From Prison.

    Science.gov (United States)

    Sugie, Naomi F; Lens, Michael C

    2017-04-01

    Individuals recently released from prison confront many barriers to employment. One potential obstacle is spatial mismatch-the concentration of low-skilled, nonwhite job-seekers within central cities and the prevalence of relevant job opportunities in outlying areas. Prior research has found mixed results about the importance of residential place for reentry outcomes. In this article, we propose that residential location matters for finding work, but this largely static measure does not capture the range of geographic contexts that individuals inhabit throughout the day. We combine novel, real-time GPS information on daytime locations and self-reported employment collected from smartphones with sophisticated measures of job accessibility to test the relative importance of spatial mismatch based on residence and daytime locations. Our findings suggest that the ability of low-skilled, poor, and urban individuals to compensate for their residential deficits by traveling to job-rich areas is an overlooked and salient consideration in spatial mismatch perspectives.

  9. Field trial of three different Plasmodium vivax-detecting rapid diagnostic tests with and without evaporative cool box storage in Afghanistan

    Directory of Open Access Journals (Sweden)

    Mohammad Nader

    2011-06-01

    Full Text Available Abstract Background Accurate parasitological diagnosis of malaria is essential for targeting treatment where more than one species coexist. In this study, three rapid diagnostic tests (RDTs (AccessBio CareStart (CSPfPan, CareStart PfPv (CSPfPv and Standard Diagnostics Bioline (SDBPfPv were evaluated for their ability to detect natural Plasmodium vivax infections in a basic clinic setting. The potential for locally made evaporative cooling boxes (ECB to protect the tests from heat damage in high summer temperatures was also investigated. Methods Venous blood was drawn from P. vivax positive patients in Jalalabad, Afghanistan and tested against a panel of six RDTs. The panel comprised two of each test type; one group was stored at room temperature and the other in an ECB. RDT results were evaluated against a consensus gold standard based on two double-read reference slides and PCR. The sensitivity, specificity and a measure of global performance for each test were determined and stratified by parasitaemia level and storage condition. Results In total, 306 patients were recruited, of which 284 were positive for P. vivax, one for Plasmodium malariae and none for Plasmodium falciparum; 21 were negative. All three RDTs were specific for malaria. The sensitivity and global performance index for each test were as follows: CSPfPan [98.6%, 95.1%], CSPfPv [91.9%, 90.5%] and SDBPfPv [96.5%, 82.9%], respectively. CSPfPv was 16% less sensitive to a parasitaemia below 5,000/μL. Room temperature storage of SDBPfPv led to a high proportion of invalid results (17%, which reduced to 10% in the ECB. Throughout the testing period, the ECB maintained ~8°C reduction over ambient temperatures and never exceeded 30°C. Conclusions Of the three RDTs, the CSPfPan test was the most consistent and reliable, rendering it appropriate for this P. vivax predominant region. The CSPfPv test proved unsuitable owing to its reduced sensitivity at a parasitaemia below 5,000/

  10. Barbed Congruence of Asymmetry and Mismatch

    Institute of Scientific and Technical Information of China (English)

    Xiao-Ju Dong; Yu-Xi Fu

    2007-01-01

    The X calculus is a model of concurrent and mobile systems. It emphasizes that communications are information exchanges. In the paper, two constructions are incorporated into the framework of the chi calculus, which are asymmetric communication and mismatch condition widely used in applications. Since the barbed bisimilarity has proved its generality and gained its popularity as an effective approach to generating a reasonable observational equivalence, we study both the operational and algebraic properties of the barbed bisimilarity in this enriched calculus. The investigation supports an improved understanding of the bisimulation behaviors of the model. It also gives a general picture of how the two constructions affect the observational theory.

  11. Visual mismatch negativity: A predictive coding view

    Directory of Open Access Journals (Sweden)

    Gabor eStefanics

    2014-09-01

    Full Text Available An increasing number of studies investigate the visual mismatch negativity (vMMN or use the vMMN as a tool to probe various aspects of human cognition. This paper reviews the theoretical underpinnings of vMMN in the light of methodological considerations and provides recommendations for measuring and interpreting the vMMN. The following key issues are discussed from the experimentalist’s point of view in a predictive coding framework: 1 experimental protocols and procedures to control ‘refractoriness’ effects; 2 methods to control attention; 3 vMMN and veridical perception.

  12. STATUS OF TRISO FUEL IRRADIATIONS IN THE ADVANCED TEST REACTOR SUPPORTING HIGH-TEMPERATURE GAS-COOLED REACTOR DESIGNS

    Energy Technology Data Exchange (ETDEWEB)

    Davenport, Michael; Petti, D. A.; Palmer, Joe

    2016-11-01

    The United States Department of Energy’s Advanced Reactor Technologies (ART) Advanced Gas Reactor (AGR) Fuel Development and Qualification Program is irradiating up to seven low enriched uranium (LEU) tri-isotopic (TRISO) particle fuel (in compact form) experiments in the Advanced Test Reactor (ATR) located at the Idaho National Laboratory (INL). These irradiations and fuel development are being accomplished to support development of the next generation reactors in the United States. The experiments will be irradiated over the next several years to demonstrate and qualify new TRISO coated particle fuel for use in high temperature gas reactors. The goals of the experiments are to provide irradiation performance data to support fuel process development, to qualify fuel for normal operating conditions, to support development and validation of fuel performance and fission product transport models and codes, and to provide irradiated fuel and materials for post irradiation examination (PIE) and safety testing. The experiments, which will each consist of several independent capsules, will be irradiated in an inert sweep gas atmosphere with individual on-line temperature monitoring and control of each capsule. The sweep gas will also have on-line fission product monitoring on its effluent to track performance of the fuel in each individual capsule during irradiation. The first experiment (designated AGR-1) started irradiation in December 2006 and was completed in November 2009. The second experiment (AGR-2) started irradiation in June 2010 and completed in October 2013. The third and fourth experiments have been combined into a single experiment designated (AGR-3/4), which started its irradiation in December 2011 and completed in April 2014. Since the purpose of this experiment was to provide data on fission product migration and retention in the NGNP reactor, the design of this experiment was significantly different from the first two experiments, though the control

  13. Cool visitors

    CERN Multimedia

    2006-01-01

    Pictured, from left to right: Tim Izo (saxophone, flute, guitar), Bobby Grant (tour manager), George Pajon (guitar). What do the LHC and a world-famous hip-hop group have in common? They are cool! On Saturday, 1st July, before their appearance at the Montreux Jazz Festival, three members of the 'Black Eyed Peas' came on a surprise visit to CERN, inspired by Dan Brown's Angels and Demons. At short notice, Connie Potter (Head of the ATLAS secretariat) organized a guided tour of ATLAS and the AD 'antimatter factory'. Still curious, lead vocalist Will.I.Am met CERN physicist Rolf Landua after the concert to ask many more questions on particles, CERN, and the origin of the Universe.

  14. Repair of mismatched basepairs in mammalian DNA

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, J.H.; Hare, J.T.

    1991-08-01

    We have concentrated on three specific areas of our research plan. Our greatest emphasis is on the role of single strand nicks in influencing template strand selection in mismatch repair. We have found, that the ability of a nick in one strand to influence which strand is repaired is not a simple function of distance from the mismatched site but rather that an hot spot where a nick is more likely to have an influence can exist. The second line was production of single-genotype heteroduplexes in order to examine independently the repair of T/G and A/C mispairs within the same sequence context as in our mixed mispair preparations. We have shown preparations of supercoiled heteroduplex can be prepared that were exclusively T/G or exclusively A/C at the mispair site. The third effort has been to understand the difference in repair bias of different cell lines or different transfection conditions as it may relate to different repair systems in the cell. We have identified some of the sources of variation, including cell cycle position. We hope to continue this work to more precisely identify the phase of the cell cycle.

  15. Scale Mismatches in Management of Urban Landscapes

    Directory of Open Access Journals (Sweden)

    Christine Alfsen-Norodom

    2006-12-01

    Full Text Available Urban landscapes constitute the future environment for most of the world’s human population. An increased understanding of the urbanization process and of the effects of urbanization at multiple scales is, therefore, key to ensuring human well-being. In many conventional natural resource management regimes, incomplete knowledge of ecosystem dynamics and institutional constraints often leads to institutional management frameworks that do not match the scale of ecological patterns and processes. In this paper, we argue that scale mismatches are particularly pronounced in urban landscapes. Urban green spaces provide numerous important ecosystem services to urban citizens, and the management of these urban green spaces, including recognition of scales, is crucial to the well-being of the citizens. From a qualitative study of the current management practices in five urban green spaces within the Greater Stockholm Metropolitan Area, Sweden, we found that 1 several spatial, temporal, and functional scales are recognized, but the cross-scale interactions are often neglected, and 2 spatial and temporal meso-scales are seldom given priority. One potential effect of the neglect of ecological cross-scale interactions in these highly fragmented landscapes is a gradual reduction in the capacity of the ecosystems to provide ecosystem services. Two important strategies for overcoming urban scale mismatches are suggested: 1 development of an integrative view of the whole urban social–ecological landscape, and 2 creation of adaptive governance systems to support practical management.

  16. Mismatch repair in Streptococcus pneumoniae: relationship between base mismatches and transformation efficiencies.

    Science.gov (United States)

    Claverys, J P; Méjean, V; Gasc, A M; Sicard, A M

    1983-10-01

    Genetic transformation in Streptococcus pneumoniae involves the insertion of single-stranded pieces of donor DNA into a recipient genome. Efficiencies of transformation strongly depend on the mutations (markers) carried by donor DNA. Markers are classified according to their transforming efficiencies into very high, high, intermediate, and low efficiency. The last is approximately 1/20th as efficient as the first. This marker effect is under the control of the Hex system, which is thought to correct mismatches at the donor-recipient heteroduplex stage in transformation. To investigate this effect, wild type, mutant, and revertant DNA sequences at five genetic sites within the amiA locus were determined. The results show that low-efficiency markers arise from transitional changes A . T to G . C. The transversion A . T to T . A corresponds to an intermediate-efficiency marker. Transversions G . C to T . A and G . C to C . G lead to high-efficiency markers. Among the eight possible mismatches that could exist transiently at the heteroduplex stage in transformation, only two--namely, A/G and C/C--are not corrected by the Hex system. It is noteworthy that the four possible base pairs (A . T, T . A, G . C, and C . G) have been encountered at the very same site (amiA6 site), which constitutes a good illustration of the marker effect. DNA sequence analysis also reveals that short deletions (33 or 34 bases long) are integrated with very high efficiencies. These results confirm that the Hex system corrects point mismatches harbored in donor-recipient heteroduplexes thousands of bases long. The correction pattern of the Hex system toward multiple-base mismatches has also been investigated. Its behavior toward double-base mismatches is complex, suggesting that neighboring sequences may affect the detection of mispaired bases.

  17. Development of a fuel-rod simulator and small-diameter thermocouples for high-temperature, high-heat-flux tests in the Gas-Cooled Fast Reactor Core Flow Test Loop

    Energy Technology Data Exchange (ETDEWEB)

    McCulloch, R.W.; MacPherson, R.E.

    1983-03-01

    The Core Flow Test Loop was constructed to perform many of the safety, core design, and mechanical interaction tests in support of the Gas-Cooled Fast Reactor (GCFR) using electrically heated fuel rod simulators (FRSs). Operation includes many off-normal or postulated accident sequences including transient, high-power, and high-temperature operation. The FRS was developed to survive: (1) hundreds of hours of operation at 200 W/cm/sup 2/, 1000/sup 0/C cladding temperature, and (2) 40 h at 40 W/cm/sup 2/, 1200/sup 0/C cladding temperature. Six 0.5-mm type K sheathed thermocouples were placed inside the FRS cladding to measure steady-state and transient temperatures through clad melting at 1370/sup 0/C.

  18. A Review for Model Plant Mismatch Measures in Process Monitoring

    Institute of Scientific and Technical Information of China (English)

    王洪; 谢磊; 宋执环

    2012-01-01

    Model is usually necessary for the design of a control loop. Due to simplification and unknown dynamics, model plant mismatch is inevitable in the control loop. In process monitoring, detection of mismatch and evaluation of its influences are demanded. In this paper several mismatch measures are presented based on different model descriptions. They are categorized into different groups from different perspectives and their potential in detection and diagnosis is evaluated. Two case studies on mixing process and distillation process demonstrate the efficacy of the framework of mismatch monitoring.

  19. Progress of the Water Cooling System for CYCIAE-100

    Institute of Scientific and Technical Information of China (English)

    LI; Zhen-guo; WU; Long-cheng; LIU; Geng-guo

    2013-01-01

    The water cooling system for CYCIAE-100 has achieved a significant progress in 2013,its progress can be summarized as follows:1)The deionized water production equipment and the main circulating water cooling unit are installed and tested.2)The circulating water cooling unit for high power target and circulating water cooling unit for vacuum helium compressor are installed and tested.

  20. Automated effective band structures for defective and mismatched supercells

    Science.gov (United States)

    Brommer, Peter; Quigley, David

    2014-12-01

    In plane-wave density functional theory codes, defects and incommensurate structures are usually represented in supercells. However, interpretation of E versus k band structures is most effective within the primitive cell, where comparison to ideal structures and spectroscopy experiments are most natural. Popescu and Zunger recently described a method to derive effective band structures (EBS) from supercell calculations in the context of random alloys. In this paper, we present bs_sc2pc, an implementation of this method in the CASTEP code, which generates an EBS using the structural data of the supercell and the underlying primitive cell with symmetry considerations handled automatically. We demonstrate the functionality of our implementation in three test cases illustrating the efficacy of this scheme for capturing the effect of vacancies, substitutions and lattice mismatch on effective primitive cell band structures.

  1. ADAPTIVE CALIBRATION OF I AND Q MISMATCH IN QUADRATURE RECEIVER

    Institute of Scientific and Technical Information of China (English)

    Yang Xuexian; Hou Zifeng; Zhang Qunying; Ning Yanqing

    2002-01-01

    The mismatch of in-phase and quadrature channels in quadrature receiver affects and constrains radar detection performance in coherent radar. It is necessary to keep the in-phase and quadrature branches symmetrical. In this letter, an adaptive method to detect imbalance parameters is derived by means of evaluating channel errors from the received signal sequences.No matter how the bias degree of the gain and phase errors in I/Q channels are, the proposed adaptive scheme can obtain good calibration results. And the required calculations are only a few multiplications and additions. No need of a special test signal, the introduced method is simple to implement and easy to operate.

  2. Performance of Air-cooled Engine Cylinders Using Blower Cooling

    Science.gov (United States)

    Schey, Oscar W; Ellerbrock, Herman H , Jr

    1936-01-01

    An investigation was made to obtain information on the minimum quantity of air and power required to cool conventional air cooled cylinders at various operating conditions when using a blower. The results of these tests show that the minimum power required for satisfactory cooling with an overall blower efficiency of 100 percent varied from 2 to 6 percent of the engine power depending on the operating conditions. The shape of the jacket had a large effect on the cylinder temperatures. Increasing the air speed over the front of the cylinder by keeping the greater part of the circumference of the cylinder covered by the jacket reduced the temperatures over the entire cylinder.

  3. Resolution of Mismatched Overlap Holliday Junction Intermediates by the Tyrosine Recombinase IntDOT.

    Science.gov (United States)

    Ringwald, Kenneth; Yoneji, Sumiko; Gardner, Jeffrey

    2017-05-15

    CTnDOT is an integrated conjugative element found in Bacteroides species. CTnDOT contains and transfers antibiotic resistance genes. The element integrates into and excises from the host chromosome via a Holliday junction (HJ) intermediate as part of a site-specific recombination mechanism. The CTnDOT integrase, IntDOT, is a tyrosine recombinase with core-binding, catalytic, and amino-terminal (N) domains. Unlike well-studied tyrosine recombinases, such as lambda integrase (Int), IntDOT is able to resolve Holliday junctions containing heterology (mismatched bases) between the sites of strand exchange. All known natural isolates of CTnDOT contain mismatches in the overlap region between the sites of strand exchange. Previous work showed that IntDOT was unable to resolve synthetic Holliday junctions containing mismatched bases to products in the absence of the arm-type sites and a DNA-bending protein. We constructed synthetic HJs with the arm-type sites and tested them with the Bacteroides host factor (BHFa). We found that the addition of BHFa stimulated resolution of HJ intermediates with mismatched overlap regions to products. In addition, the L1 site is required for directionality of the reaction, particularly when the HJ contains mismatches. BHFa is required for product formation when the overlap region contains mismatches, and it stimulates resolution to products when the overlap region is identical. Without this DNA bending, the N domain of IntDOT is likely unable to bind the L1 arm-type site. These findings suggest that BHFa bends DNA into the necessary conformation for the higher-order complexes, including the L1 site, that are required for product formation.IMPORTANCE CTnDOT is a mobile element that carries antibiotic resistance genes and moves by site-selective recombination and subsequent conjugation. The recombination reaction is catalyzed by an integrase IntDOT that is a member of the tyrosine recombinase family. The reaction proceeds through ordered

  4. Hippocampal Mismatch Signals Are Modulated by the Strength of Neural Predictions and Their Similarity to Outcomes.

    Science.gov (United States)

    Long, Nicole M; Lee, Hongmi; Kuhl, Brice A

    2016-12-14

    The hippocampus is thought to compare predicted events with current perceptual input, generating a mismatch signal when predictions are violated. However, most prior studies have only inferred when predictions occur without measuring them directly. Moreover, an important but unresolved question is whether hippocampal mismatch signals are modulated by the degree to which predictions differ from outcomes. Here, we conducted a human fMRI study in which subjects repeatedly studied various word-picture pairs, learning to predict particular pictures (outcomes) from the words (cues). After initial learning, a subset of cues was paired with a novel, unexpected outcome, whereas other cues continued to predict the same outcome. Critically, when outcomes changed, the new outcome was either "near" to the predicted outcome (same visual category as the predicted picture) or "far" from the predicted outcome (different visual category). Using multivoxel pattern analysis, we indexed cue-evoked reactivation (prediction) within neocortical areas and related these trial-by-trial measures of prediction strength to univariate hippocampal responses to the outcomes. We found that prediction strength positively modulated hippocampal responses to unexpected outcomes, particularly when unexpected outcomes were close, but not identical, to the prediction. Hippocampal responses to unexpected outcomes were also associated with a tradeoff in performance during a subsequent memory test: relatively faster retrieval of new (updated) associations, but relatively slower retrieval of the original (older) associations. Together, these results indicate that hippocampal mismatch signals reflect a comparison between active predictions and current outcomes and that these signals are most robust when predictions are similar, but not identical, to outcomes. Although the hippocampus is widely thought to signal "mismatches" between memory-based predictions and outcomes, previous research has not linked

  5. Manufacturing and high heat-flux testing of brazed actively cooled mock-ups with Ti-doped graphite and CFC as plasma-facing materials

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Rosales, C; Ordas, N; Lopez-Galilea, I [CEIT and Tecnun (University of Navarra), 20018 San Sebastian (Spain); Pintsuk, G; Linke, J [Forschungszentrum Juelich GmbH, EURATOM Association, 52425 Juelich (Germany); Gualco, C; Grattarola, M; Mataloni, F [Ansaldo Ricerche S.p.A., I-16152 Genoa (Italy); Ramos Fernandez, J M; MartInez Escandell, M [Departamento de Quimica Inorganica, University of Alicante, E-03690 Alicante (Spain); Centeno, A; Blanco, C [Instituto Nacional del Carbon (CSIC), Apdo. 73, E-33080 Oviedo (Spain)], E-mail: cgrosales@ceit.es

    2009-12-15

    In the frame of the EU project ExtreMat new Ti-doped isotropic graphites and carbon fibre-reinforced carbons (CFCs) with high thermal conductivity and reduced chemical erosion were brazed to a CuCrZr heat-sink to produce flat-tile actively cooled mock-ups (MUs). Brazing was done using a low CTE interlayer to shift the stresses to the metal-metal interface. These MUs were exposed to high heat-fluxes in the electron beam facility JUDITH. Screening tests were conducted increasing the heat load stepwise up to 15 MW m{sup -2}, followed by 100 cycles at 15 MW m{sup -2}, subsequent screening up to 20 MW m{sup -2} and 100 cycles at 20 MW m{sup -2}. All MUs withstood screening at 15 MW m{sup -2} and most of them survived screening at 20 MW m{sup -2}. Ti-doped CFC MUs showed a significant improvement compared with the undoped reference CFC, surviving several cycles at 20 MW m{sup -2} on all tiles. One of the Ti-doped graphite MUs withstood 100 cycles at 20 MW m{sup -2} on one tile, representing a promising result.

  6. Laboratory Studies of Technological Strength of Heat-Resistant Steels 15H1N1F Using the Small Sample Tests with Artificial Cooling

    Directory of Open Access Journals (Sweden)

    V. S. Drizhov

    2015-01-01

    under numerous test conditions has shown that it is reasonable to use the artificial heat sink small samples to study both damages under reiterated heating and cooling cracks.

  7. Design and analysis of mismatch probes for long oligonucleotide microarrays

    Energy Technology Data Exchange (ETDEWEB)

    Deng, Ye; He, Zhili; Van Nostrand, Joy D.; Zhou, Jizhong

    2008-08-15

    Nonspecific hybridization is currently a major concern with microarray technology. One of most effective approaches to estimating nonspecific hybridizations in oligonucleotide microarrays is the utilization of mismatch probes; however, this approach has not been used for longer oligonucleotide probes. Here, an oligonucleotide microarray was constructed to evaluate and optimize parameters for 50-mer mismatch probe design. A perfect match (PM) and 28 mismatch (MM) probes were designed for each of ten target genes selected from three microorganisms. The microarrays were hybridized with synthesized complementary oligonucleotide targets at different temperatures (e.g., 42, 45 and 50 C). In general, the probes with evenly distributed mismatches were more distinguishable than those with randomly distributed mismatches. MM probes with 3, 4 and 5 mismatched nucleotides were differentiated for 50-mer oligonucleotide probes hybridized at 50, 45 and 42 C, respectively. Based on the experimental data generated from this study, a modified positional dependent nearest neighbor (MPDNN) model was constructed to adjust the thermodynamic parameters of matched and mismatched dimer nucleotides in the microarray environment. The MM probes with four flexible positional mismatches were designed using the newly established MPDNN model and the experimental results demonstrated that the redesigned MM probes could yield more consistent hybridizations. Conclusions: This study provides guidance on the design of MM probes for long oligonucleotides (e.g., 50 mers). The novel MPDNN model has improved the consistency for long MM probes, and this modeling method can potentially be used for the prediction of oligonucleotide microarray hybridizations.

  8. Mismatch Analysis of TAB-on-Glass Connection With ACF

    Science.gov (United States)

    2000-07-01

    element model be used in the mismatch analysis if a more accurate prediction of OLB mismatch is desired. REFERENCES 1. H. Atarashi, N. Kakimoto , H...Yamamura, N. Kakimoto , K. Naitoh, and T. Nukii, "Bare-chip face-down bonding technology using conductive particles and lightsetting adhesives:ELASTIC

  9. Influence of halo doping profiles on MOS transistor mismatch

    NARCIS (Netherlands)

    Andricciola, P.; Tuinhout, H.

    2009-01-01

    Halo implants are used in modern CMOS technology to reduce the short channel effect. However, the lateral non-uniformity of the channel doping has been proven to degenerate the mismatch performance. With this paper we want to discuss the influence of the halo profile on MOS transistor mismatch. The

  10. Design and analysis of mismatch probes for long oligonucleotide microarrays

    Energy Technology Data Exchange (ETDEWEB)

    Deng, Ye; He, Zhili; Van Nostrand, Joy D.; Zhou, Jizhong

    2008-08-15

    Nonspecific hybridization is currently a major concern with microarray technology. One of most effective approaches to estimating nonspecific hybridizations in oligonucleotide microarrays is the utilization of mismatch probes; however, this approach has not been used for longer oligonucleotide probes. Here, an oligonucleotide microarray was constructed to evaluate and optimize parameters for 50-mer mismatch probe design. A perfect match (PM) and 28 mismatch (MM) probes were designed for each of ten target genes selected from three microorganisms. The microarrays were hybridized with synthesized complementary oligonucleotide targets at different temperatures (e.g., 42, 45 and 50 C). In general, the probes with evenly distributed mismatches were more distinguishable than those with randomly distributed mismatches. MM probes with 3, 4 and 5 mismatched nucleotides were differentiated for 50-mer oligonucleotide probes hybridized at 50, 45 and 42 C, respectively. Based on the experimental data generated from this study, a modified positional dependent nearest neighbor (MPDNN) model was constructed to adjust the thermodynamic parameters of matched and mismatched dimer nucleotides in the microarray environment. The MM probes with four flexible positional mismatches were designed using the newly established MPDNN model and the experimental results demonstrated that the redesigned MM probes could yield more consistent hybridizations. Conclusions: This study provides guidance on the design of MM probes for long oligonucleotides (e.g., 50 mers). The novel MPDNN model has improved the consistency for long MM probes, and this modeling method can potentially be used for the prediction of oligonucleotide microarray hybridizations.

  11. Mismatch-Shaped Pseudo-Passive Two-Capacitor DAC

    DEFF Research Database (Denmark)

    Steensgaard-Madsen, Jesper; Moon, Un-Ku; Temes, Gabor C.

    1999-01-01

    A simple mismatch-shaping scheme is proposed for a two-capacitor DAC. Unlike in other mismatch-shaping systems, the shaped error is generated by direct filtering of a well-defined bounded signal, which can be generated as white noise. The operation is closely related to a specific digital interpo...

  12. Mismatch-Shaping Serial Digital-to-Analog Converter

    DEFF Research Database (Denmark)

    Steensgaard-Madsen, Jesper; Moon, Un-Ku; Temes, Gabor C.

    1999-01-01

    A simple but accurate pseudo-passive mismatch-shaping D/A converter is described. A digital state machine is used to control the switching sequence of a symmetric two-capacitor network that performs the D/A conversion. The error caused by capacitor mismatch is uncorrelated with the input signal a...

  13. Speaking Self-Assessment: Mismatches between Learners' and Teachers' Criteria

    Science.gov (United States)

    Babaii, Esmat; Taghaddomi, Shahin; Pashmforoosh, Roya

    2016-01-01

    Perceptual (mis)matches between teachers and learners are said to affect learning success or failure. Self-assessment, as a formative assessment tool, may, inter alia, be considered a means to minimize such mismatches. Therefore, the present study investigated the extent to which learners' assessment of their own speaking performance, before and…

  14. Educational Mismatch of Graduates: A Multidimensional and Fuzzy Indicator

    Science.gov (United States)

    Betti, Gianni; D'Agostino, Antonella; Neri, Laura

    2011-01-01

    In this paper we attempt to measure the educational mismatch, seen as a problem of overeducation, using a multidimensional and fuzzy methodology. Educational mismatch can be difficult to measure because many factors can converge to its definition and the traditional unidimensional indicators presented in literature can offer a restricted view of…

  15. Key achievements in elementary R&D on water-cooled solid breeder blanket for ITER test blanket module in JAERI

    Science.gov (United States)

    Suzuki, S.; Enoeda, M.; Hatano, T.; Hirose, T.; Hayashi, K.; Tanigawa, H.; Ochiai, K.; Nishitani, T.; Tobita, K.; Akiba, M.

    2006-02-01

    This paper presents the significant progress made in the research and development (R&D) of key technologies on the water-cooled solid breeder blanket for the ITER test blanket modules in JAERI. Development of module fabrication technology, bonding technology of armours, measurement of thermo-mechanical properties of pebble beds, neutronics studies on a blanket module mockup and tritium release behaviour from a Li2TiO3 pebble bed under neutron-pulsed operation conditions are summarized. With the improvement of the heat treatment process for blanket module fabrication, a fine-grained microstructure of F82H can be obtained by homogenizing it at 1150 °C followed by normalizing it at 930 °C after the hot isostatic pressing process. Moreover, a promising bonding process for a tungsten armour and an F82H structural material was developed using a solid-state bonding method based on uniaxial hot compression without any artificial compliant layer. As a result of high heat flux tests of F82H first wall mockups, it has been confirmed that a fatigue lifetime correlation, which was developed for the ITER divertor, can be made applicable for the F82H first wall mockup. As for R&D on the breeder material, Li2TiO3, the effect of compression loads on effective thermal conductivity of pebble beds has been clarified for the Li2TiO3 pebble bed. The tritium breeding ratio of a simulated multi-layer blanket structure has successfully been measured using 14 MeV neutrons with an accuracy of 10%. The tritium release rate from the Li2TiO3 pebble has also been successfully measured with pulsed neutron irradiation, which simulates ITER operation.

  16. A periodic table of symmetric tandem mismatches in RNA.

    Science.gov (United States)

    Wu, M; McDowell, J A; Turner, D H

    1995-03-14

    The stabilities and structures of a series of RNA octamers containing symmetric tandem mismatches were studied by UV melting and imino proton NMR. The free energy increments for tandem mismatch formation are found to depend upon both mismatch sequence and adjacent base pairs. The observed sequence dependence of tandem mismatch stability is UGGU > GUUG > GAAG > or = AGGA > UUUU > CAAC > or = CUUC approximately UCCU approximately CCCC approximately ACCA approximately AAAA, and the closing base pair dependence is 5'G3'C > 5'C3'G > 5'U3'A approximately 5'A3'U. These results differ from expectations based on models used in RNA folding algorithms and from the sequence dependence observed for folding of RNA hairpins. Imino proton NMR results indicate the sequence dependence is partially due to hydrogen bonding within mismatches.

  17. The effect of base pair mismatch on DNA strand displacement

    CERN Document Server

    Broadwater, Bo

    2016-01-01

    DNA strand displacement is a key reaction in DNA homologous recombination and DNA mismatch repair and is also heavily utilized in DNA-based computation and locomotion. Despite its ubiquity in science and engineering, sequence-dependent effects of displacement kinetics have not been extensively characterized. Here, we measured toehold-mediated strand displacement kinetics using single-molecule fluorescence in the presence of a single base pair mismatch. The apparent displacement rate varied significantly when the mismatch was introduced in the invading DNA strand. The rate generally decreased as the mismatch in the invader was encountered earlier in displacement. Our data indicate that a single base pair mismatch in the invader stalls branch migration, and displacement occurs via direct dissociation of the destabilized incumbent strand from the substrate strand. We combined both branch migration and direct dissociation into a model, which we term, the concurrent displacement model, and used the first passage t...

  18. Heterogenous mismatch-repair status in colorectal cancer

    DEFF Research Database (Denmark)

    Joost, Patrick; Veurink, Nynke; Holck, Susanne;

    2014-01-01

    , heterogenous mismatch repair protein staining in order to delineate expression patterns and underlying mechanisms. METHODS: Heterogenous staining patterns that affected at least one of the mismatch repair proteins MLH1, PMS2, MSH2 and MSH6 were identified in 14 colorectal cancers. Based on alternative...... expression patterns macro-dissected and micro-dissected tumor areas were separately analyzed for microsatellite instability and MLH1 promoter methylation. RESULTS: Heterogenous retained/lost mismatch repair protein expression could be classified as intraglandular (within or in-between glandular formations....... CONCLUSIONS: Heterogenous mismatch repair status can be demonstrated in colorectal cancer. Though rare, attention to this phenomenon is recommended since it corresponds to differences in mismatch repair status that are relevant for correct classification. VIRTUAL SLIDES: The virtual slide(s) for this article...

  19. Micro channel evaporative $CO_2$ cooling for the upgrade of the LHCb vertex detector

    CERN Document Server

    Buytaert, J; Dumps, R; Greening, E; John, M; Leflat, A; Li, Y; Mapelli, A; Nomerotski, A; Romagnoli, G; Verlaat, B

    2013-01-01

    Local thermal management of detector electronics through ultra-thin micro-structured silicon cooling plates is a very promising technique for pixel detectors in high energy physics experiments, especially at the LHC where the heavily irradiated sensors must be operated at temperatures below − 20 1 C. It combines a very high thermal ef fi ciency with a very low addition of mass and space, and suppresses all problems of CTE mismatch between the heat source and the heat sink. In addition, the use of CO 2 as evaporative coolant liquid brings all the bene fi ts of reliable and stable operation, but the high pressures involved impose additional challenges on the micro channel design and the fl uidic connectivity. A series of designs have already been prototyped and tested for LHCb. The challenges, the current status of the measurements and the solutions under development will be described

  20. The contrasting structures of mismatched DNA sequences containing looped-out bases (bulges) and multiple mismatches (bubbles).

    Science.gov (United States)

    Bhattacharyya, A; Lilley, D M

    1989-09-12

    We have studied the structure and reactivities of two kinds of mismatched DNA sequences--unopposed bases, or bulges, and multiple mismatched pairs of bases. These were generated in a constant sequence environment, in relatively long DNA fragments, using a technique based on heteroduplex formation between sequences cloned into single-stranded M13 phage. The mismatched sequences were studied from two points of view, viz 1. The mobility of the fragments on gel electrophoresis in polyacrylamide was studied in order to examine possible bending of the DNA due to the presence of the mismatch defect. Such bending would constitute a global effect on the conformation of the molecule. 2. Sequences in and around the mismatches were studied using enzyme and chemical probes of DNA structure. This would reveal more local structural effects of the mismatched sequences. We observed that the structures of the bulges and the multiple mismatches appear to be fundamentally different. The bulged sequences exhibited a large gel retardation, consistent with a significant bending of the DNA at the bulge, and whose magnitude depends on the number of mismatched bases. The larger bulges were sensitive to cleavage by single-strand specific nucleases, and modified by diethyl pyrocarbonate (adenines) or osmium tetroxide (thymines) in a non-uniform way, suggesting that the bulges have a precise structure that leads to exposure of some, but not all, of the bases. In contrast the multiple mismatches ('bubbles') cause very much less bending of the DNA fragment in which they occur, and uniform patterns of chemical reactivity along the length of the mismatched sequences, suggesting a less well defined, and possibly flexible, structure. The precise structure of the bulges suggests that such features may be especially significant for recognition by proteins.

  1. The poor homology stringency in the heteroduplex allows strand exchange to incorporate desirable mismatches without sacrificing recognition in vivo.

    Science.gov (United States)

    Danilowicz, Claudia; Yang, Darren; Kelley, Craig; Prévost, Chantal; Prentiss, Mara

    2015-07-27

    RecA family proteins are responsible for homology search and strand exchange. In bacteria, homology search begins after RecA binds an initiating single-stranded DNA (ssDNA) in the primary DNA-binding site, forming the presynaptic filament. Once the filament is formed, it interrogates double-stranded DNA (dsDNA). During the interrogation, bases in the dsDNA attempt to form Watson-Crick bonds with the corresponding bases in the initiating strand. Mismatch dependent instability in the base pairing in the heteroduplex strand exchange product could provide stringent recognition; however, we present experimental and theoretical results suggesting that the heteroduplex stability is insensitive to mismatches. We also present data suggesting that an initial homology test of 8 contiguous bases rejects most interactions containing more than 1/8 mismatches without forming a detectable 20 bp product. We propose that, in vivo, the sparsity of accidental sequence matches allows an initial 8 bp test to rapidly reject almost all non-homologous sequences. We speculate that once the initial test is passed, the mismatch insensitive binding in the heteroduplex allows short mismatched regions to be incorporated in otherwise homologous strand exchange products even though sequences with less homology are eventually rejected. © The Author(s) 2015. Published by Oxford University Press on behalf of Nucleic Acids Research.

  2. [Avoidance of patient-prosthesis mismatch].

    Science.gov (United States)

    Sakamoto, Y; Hashimoto, K

    2006-04-01

    To minimize the incidence of patient-prosthesis mismatch (PPM), we have routinely adopted aortic root enlargement to avoid PPM for patients with small aortic annulus. The aim of this study was to review our strategy of avoiding PPM. The Carpentier-Edwards Perimount (CEP) valves were implanted in 53 patients who were mostly aged over 65 and the St. Jude Medical (SJM) mechanical valves were used in 128 patients aged under 65. A standard 21-mm SJM valve was used in only 3 patients and no 19-mm valves were employed. However, 19-mm CEP valves were used in 12 patients with a small body surface area (1.43 +/- 0.14 m2). Of these, 26 patients (14.4%) who had a small aortic annulus and 24 patients aged under 65 underwent aortic root enlargement. No patient receiving an SJM valve had an projected indexed effective orifice area (EOAI) small annulus, the first choice for avoiding PPM is aortic annular enlargement, which may be avoided by high performance mechanical valves with larger EOA.

  3. Design and Control of Hydronic Radiant Cooling Systems

    Science.gov (United States)

    Feng, Jingjuan

    Improving energy efficiency in the Heating Ventilation and Air conditioning (HVAC) systems in buildings is critical to achieve the energy reduction in the building sector, which consumes 41% of all primary energy produced in the United States, and was responsible for nearly half of U.S. CO2 emissions. Based on a report by the New Building Institute (NBI), when HVAC systems are used, about half of the zero net energy (ZNE) buildings report using a radiant cooling/heating system, often in conjunction with ground source heat pumps. Radiant systems differ from air systems in the main heat transfer mechanism used to remove heat from a space, and in their control characteristics when responding to changes in control signals and room thermal conditions. This dissertation investigates three related design and control topics: cooling load calculations, cooling capacity estimation, and control for the heavyweight radiant systems. These three issues are fundamental to the development of accurate design/modeling tools, relevant performance testing methods, and ultimately the realization of the potential energy benefits of radiant systems. Cooling load calculations are a crucial step in designing any HVAC system. In the current standards, cooling load is defined and calculated independent of HVAC system type. In this dissertation, I present research evidence that sensible zone cooling loads for radiant systems are different from cooling loads for traditional air systems. Energy simulations, in EnergyPlus, and laboratory experiments were conducted to investigate the heat transfer dynamics in spaces conditioned by radiant and air systems. The results show that the magnitude of the cooling load difference between the two systems ranges from 7-85%, and radiant systems remove heat faster than air systems. For the experimental tested conditions, 75-82% of total heat gain was removed by radiant system during the period when the heater (simulating the heat gain) was on, while for air

  4. Studies Related to the Oregon State University High Temperature Test Facility: Scaling, the Validation Matrix, and Similarities to the Modular High Temperature Gas-Cooled Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Richard R. Schultz; Paul D. Bayless; Richard W. Johnson; William T. Taitano; James R. Wolf; Glenn E. McCreery

    2010-09-01

    The Oregon State University (OSU) High Temperature Test Facility (HTTF) is an integral experimental facility that will be constructed on the OSU campus in Corvallis, Oregon. The HTTF project was initiated, by the U.S. Nuclear Regulatory Commission (NRC), on September 5, 2008 as Task 4 of the 5 year High Temperature Gas Reactor Cooperative Agreement via NRC Contract 04-08-138. Until August, 2010, when a DOE contract was initiated to fund additional capabilities for the HTTF project, all of the funding support for the HTTF was provided by the NRC via their cooperative agreement. The U.S. Department of Energy (DOE) began their involvement with the HTTF project in late 2009 via the Next Generation Nuclear Plant project. Because the NRC interests in HTTF experiments were only centered on the depressurized conduction cooldown (DCC) scenario, NGNP involvement focused on expanding the experimental envelope of the HTTF to include steady-state operations and also the pressurized conduction cooldown (PCC). Since DOE has incorporated the HTTF as an ingredient in the NGNP thermal-fluids validation program, several important outcomes should be noted: 1. The reference prismatic reactor design, that serves as the basis for scaling the HTTF, became the modular high temperature gas-cooled reactor (MHTGR). The MHTGR has also been chosen as the reference design for all of the other NGNP thermal-fluid experiments. 2. The NGNP validation matrix is being planned using the same scaling strategy that has been implemented to design the HTTF, i.e., the hierarchical two-tiered scaling methodology developed by Zuber in 1991. Using this approach a preliminary validation matrix has been designed that integrates the HTTF experiments with the other experiments planned for the NGNP thermal-fluids verification and validation project. 3. Initial analyses showed that the inherent power capability of the OSU infrastructure, which only allowed a total operational facility power capability of 0.6 MW, is

  5. Hybrid radiator cooling system

    Science.gov (United States)

    France, David M.; Smith, David S.; Yu, Wenhua; Routbort, Jules L.

    2016-03-15

    A method and hybrid radiator-cooling apparatus for implementing enhanced radiator-cooling are provided. The hybrid radiator-cooling apparatus includes an air-side finned surface for air cooling; an elongated vertically extending surface extending outwardly from the air-side finned surface on a downstream air-side of the hybrid radiator; and a water supply for selectively providing evaporative cooling with water flow by gravity on the elongated vertically extending surface.

  6. Parametric Adaptive Radar Detector with Enhanced Mismatched Signals Rejection Capabilities

    Directory of Open Access Journals (Sweden)

    Liu Bin

    2010-01-01

    Full Text Available We consider the problem of adaptive signal detection in the presence of Gaussian noise with unknown covariance matrix. We propose a parametric radar detector by introducing a design parameter to trade off the target sensitivity with sidelobes energy rejection. The resulting detector merges the statistics of Kelly's GLRT and of the Rao test and so covers Kelly's GLRT and the Rao test as special cases. Both invariance properties and constant false alarm rate (CFAR behavior for this detector are studied. At the analysis stage, the performance of the new receiver is assessed and compared with several traditional adaptive detectors. The results highlight better rejection capabilities of this proposed detector for mismatched signals. Further, we develop two two-stage detectors, one of which consists of an adaptive matched filter (AMF followed by the aforementioned detector, and the other is obtained by cascading a GLRT-based Subspace Detector (SD and the proposed adaptive detector. We show that the former two-stage detector outperforms traditional two-stage detectors in terms of selectivity, and the latter yields more robustness.

  7. Oblique effect in visual mismatch negativity

    Directory of Open Access Journals (Sweden)

    Endre eTakács

    2013-09-01

    Full Text Available We investigated whether visual orientation anisotropies (known as oblique effect exist in non-attended visual changes using event-related potentials (ERP. We recorded visual mismatch negativity (vMMN which signals violation of sequential regularities. In the visual periphery unattended, task-irrelevant Gábor patches were displayed in an oddball sequence while subjects performed a tracking task in the central field. A moderate change (50° in the orientation of stimuli revealed no consistent change-related components. However we found orientation-related differences around 170 ms in occipito-temporal areas in the amplitude of the ERPs evoked by standard stimuli. In a supplementary experiment we determined the amount of orientation difference that is needed for change detection in an active, attended paradigm. Results exhibited the classical oblique effect; subjects detected 10° deviations from cardinal directions, while threshold from oblique directions was 17°. These results provide evidence that perception of change could be accomplished at significantly smaller thresholds, than what elicits vMMN. In Experiment2 we increased the orientation change to 90°. Deviant-minus-standard difference was negative in occipito-parietal areas, between 120-200 ms after stimulus onset. VMMNs to changes from cardinal angles were larger and more sustained than vMMNs evoked by changes from oblique angles. Changes from cardinal orientations represent a more detectable signal for the automatic change detection system than changes from oblique angles, thus increased vMMN to these larger deviances might be considered a variant of the magnitude of deviance effect rarely observed in vMMN studies.

  8. Energy Efficient Electronics Cooling Project

    Energy Technology Data Exchange (ETDEWEB)

    Steve O' Shaughnessey; Tim Louvar; Mike Trumbower; Jessica Hunnicutt; Neil Myers

    2012-02-17

    Parker Precision Cooling Business Unit was awarded a Department of Energy grant (DE-EE0000412) to support the DOE-ITP goal of reducing industrial energy intensity and GHG emissions. The project proposed by Precision Cooling was to accelerate the development of a cooling technology for high heat generating electronics components. These components are specifically related to power electronics found in power drives focused on the inverter, converter and transformer modules. The proposed cooling system was expected to simultaneously remove heat from all three of the major modules listed above, while remaining dielectric under all operating conditions. Development of the cooling system to meet specific customer's requirements and constraints not only required a robust system design, but also new components to support long system functionality. Components requiring further development and testing during this project included pumps, fluid couplings, cold plates and condensers. All four of these major categories of components are required in every Precision Cooling system. Not only was design a key area of focus, but the process for manufacturing these components had to be determined and proven through the system development.

  9. Thermal-Hydraulic Analysis of an Experimental Reactor Cavity Cooling System with Air. Part I: Experiments; Part II: Separate Effects Tests and Modeling

    Energy Technology Data Exchange (ETDEWEB)

    Corradin, Michael [Univ. of Wisconsin, Madison, WI (United States). Dept. of Engineering Physics; Anderson, M. [Univ. of Wisconsin, Madison, WI (United States). Dept. of Engineering Physics; Muci, M. [Univ. of Wisconsin, Madison, WI (United States). Dept. of Engineering Physics; Hassan, Yassin [Texas A & M Univ., College Station, TX (United States); Dominguez, A. [Texas A & M Univ., College Station, TX (United States); Tokuhiro, Akira [Univ. of Idaho, Moscow, ID (United States); Hamman, K. [Univ. of Idaho, Moscow, ID (United States)

    2014-10-15

    This experimental study investigates the thermal hydraulic behavior and the heat removal performance for a scaled Reactor Cavity Cooling System (RCCS) with air. A quarter-scale RCCS facility was designed and built based on a full-scale General Atomics (GA) RCCS design concept for the Modular High Temperature Gas Reactor (MHTGR). The GA RCCS is a passive cooling system that draws in air to use as the cooling fluid to remove heat radiated from the reactor pressure vessel to the air-cooled riser tubes and discharged the heated air into the atmosphere. Scaling laws were used to preserve key aspects and to maintain similarity. The scaled air RCCS facility at UW-Madison is a quarter-scale reduced length experiment housing six riser ducts that represent a 9.5° sector slice of the full-scale GA air RCCS concept. Radiant heaters were used to simulate the heat radiation from the reactor pressure vessel. The maximum power that can be achieved with the radiant heaters is 40 kW with a peak heat flux of 25 kW per meter squared. The quarter-scale RCCS was run under different heat loading cases and operated successfully. Instabilities were observed in some experiments in which one of the two exhaust ducts experienced a flow reversal for a period of time. The data and analysis presented show that the RCCS has promising potential to be a decay heat removal system during an accident scenario.

  10. Communication in the Home and Classroom: Match or Mismatch?

    Science.gov (United States)

    Iglesias, Aquiles

    1985-01-01

    The article examines variations in communication of cultural-linguistic minority children at home and in school and describes a communicative match/mismatch model. Implications of educational policy and program development are noted. (CL)

  11. Elastic-plastic fracture mechanics of strength-mismatching

    Energy Technology Data Exchange (ETDEWEB)

    Parks, D.M.; Ganti, S.; McClintock, F.A. [Massachusetts Institute of Technology, Cambridge, MA (United States)

    1996-12-31

    Approximate solutions to stress-fields are provided for a strength-mismatched interface crack in small-scale yielding (SSY) for non-hardening and low hardening materials. Variations of local deformation intensities, characterized by a J-type contour integral, are proposed. The softer material experiences a higher deformation intensity level, J{sub S}, while the harder material sees a much lower deformation intensity level, J{sub H}, compared to that obtained from the applied J near the respective homogeneous crack-tips. For a low hardening material, the stress fields are obtained by scaling from an elastic/perfectly-plastic problem, based on an effective mismatch, M{sub eff}, which is a function of mismatch, M, and the hardening exponent, n. Triaxial stress build-up is discussed quantitatively in terms of M. The influence of strength-mismatch on cleavage fracture is discussed using Weibull statistics.

  12. Use of local convective and radiant cooling at warm environment

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor; Krejcirikova, Barbora; Kaczmarczyk, Jan

    2012-01-01

    with one panel equipped with small fans. A reference condition without cooling was tested as well. The response of the subjects to the exposed conditions was collected by computerized questionnaires. The cooling devices significantly (p.... The acceptability of the thermal environment was similar for all cooling devices. The acceptability of air movement and PAQ increased when the local cooling methods were used. The best results were achieved with personalized ventilation and cooling fan. The minimal improvement in PAQ was reported when the radiant...

  13. Robust Control of Urban Industrial Water Mismatching Uncertain System

    Directory of Open Access Journals (Sweden)

    LI Kebai

    2013-02-01

    Full Text Available Urban industrial water system parameter fluctuation producing uncertainty may not occur in a control input channel, can be applied mismatching uncertain system to describe. Based on Lyapunov direct method and linear matrix inequality, design the urban industrial water mismatching uncertain system feedback stabilization robust control scheme. Avoid the defects that the feedback stabilization control method based on the matrix Riccati equation need to preset equation parameters, easier to solve and can reduce the conservative.

  14. User image mismatch in anaesthesia alarms: a cognitive systems analysis.

    Science.gov (United States)

    Raymer, Karen E; Bergström, Johan

    2013-01-01

    In this study, principles of Cognitive Systems Engineering are used to better understand the human-machine interaction manifesting in the use of anaesthesia alarms. The hypothesis is that the design of the machine incorporates built-in assumptions of the user that are discrepant with the anaesthesiologist's self-assessment, creating 'user image mismatch'. Mismatch was interpreted by focusing on the 'user image' as described from the perspectives of both machine and user. The machine-embedded image was interpreted through document analysis. The user-described image was interpreted through user (anaesthesiologist) interviews. Finally, an analysis was conducted in which the machine-embedded and user-described images were contrasted to identify user image mismatch. It is concluded that analysing user image mismatch expands the focus of attention towards macro-elements in the interaction between man and machine. User image mismatch is interpreted to arise from complexity of algorithm design and incongruity between alarm design and tenets of anaesthesia practice. Cognitive system engineering principles are applied to enhance the understanding of the interaction between anaesthesiologist and alarm. The 'user image' is interpreted and contrasted from the perspectives of machine as well as the user. Apparent machine-user mismatch is explored pertaining to specific design features.

  15. Shape forming by thermal expansion mismatch and shape memory locking in polymer/elastomer laminates

    Science.gov (United States)

    Yuan, Chao; Ding, Zhen; Wang, T. J.; Dunn, Martin L.; Qi, H. Jerry

    2017-10-01

    This paper studies a novel method to fabricate three-dimensional (3D) structure from 2D thermo-responsive shape memory polymer (SMP)/elastomer bilayer laminate. In this method, the shape change is actuated by the thermal mismatch strain between the SMP and the elastomer layers upon heating. However, the glass transition behavior of the SMP locks the material into a new 3D shape that is stable even upon cooling. Therefore, the second shape becomes a new permanent shape of the laminate. A theoretical model that accounts for the temperature-dependent thermomechanical behavior of the SMP material and thermal mismatch strain between the two layers is developed to better understand the underlying physics. Model predictions and experiments show good agreement and indicate that the theoretical model can well predict the bending behavior of the bilayer laminate. The model is then used in the optimal design of geometrical configuration and material selection. The latter also illustrates the requirement of thermomechanical behaviors of the SMP to lock the shape. Based on the fundamental understandings, several self-folding structures are demonstrated by the bilayer laminate design.

  16. Modelling trial-by-trial changes in the mismatch negativity.

    Directory of Open Access Journals (Sweden)

    Falk Lieder

    Full Text Available The mismatch negativity (MMN is a differential brain response to violations of learned regularities. It has been used to demonstrate that the brain learns the statistical structure of its environment and predicts future sensory inputs. However, the algorithmic nature of these computations and the underlying neurobiological implementation remain controversial. This article introduces a mathematical framework with which competing ideas about the computational quantities indexed by MMN responses can be formalized and tested against single-trial EEG data. This framework was applied to five major theories of the MMN, comparing their ability to explain trial-by-trial changes in MMN amplitude. Three of these theories (predictive coding, model adjustment, and novelty detection were formalized by linking the MMN to different manifestations of the same computational mechanism: approximate Bayesian inference according to the free-energy principle. We thereby propose a unifying view on three distinct theories of the MMN. The relative plausibility of each theory was assessed against empirical single-trial MMN amplitudes acquired from eight healthy volunteers in a roving oddball experiment. Models based on the free-energy principle provided more plausible explanations of trial-by-trial changes in MMN amplitude than models representing the two more traditional theories (change detection and adaptation. Our results suggest that the MMN reflects approximate Bayesian learning of sensory regularities, and that the MMN-generating process adjusts a probabilistic model of the environment according to prediction errors.

  17. Systematic misestimation in a vernier task arising from contrast mismatch.

    Science.gov (United States)

    Sun, Hao; Lee, Barry B; Baraas, Rigmor C

    2008-01-01

    Luminance signals mediated by the magnocellular (MC) pathway play an important role in vernier tasks. MC ganglion cells show a phase advance in their responses to sinusoidal stimuli with increasing contrast due to contrast gain control mechanisms. If the phase information in MC ganglion cell responses were utilized by central mechanisms in vernier tasks, one might expect systematic errors caused by the phase advance. This systematic error may contribute to the contrast paradox phenomenon, where vernier performance deteriorates, rather than improves, when only one of the target pair increases in contrast. Vernier psychometric functions for a pair of gratings of mismatched contrast were measured to seek such misestimation. In associated electrophysiological experiments, MC and parvocellular (PC) ganglion cells' responses to similar stimuli were measured to provide a physiological reference. The psychophysical experiments show that a high-contrast grating is perceived as phase advanced in the drift direction compared to a low-contrast grating, especially at a high drift rate (8 Hz). The size of the phase advance was comparable to that seen in MC cells under similar stimulus conditions. These results are consistent with the MC pathway supporting vernier performance with achromatic gratings. The shifts in vernier psychometric functions were negligible for pairs of chromatic gratings under the conditions tested here, consistent with the lack of phase advance both in responses of PC ganglion cells and in frequency-doubled chromatic responses of MC ganglion cells.

  18. The Visual Mismatch Negativity Elicited with Visual Speech Stimuli

    Directory of Open Access Journals (Sweden)

    Benjamin T. Files

    2013-07-01

    Full Text Available The visual mismatch negativity (vMMN, deriving from the brain’s response to stimulus deviance, is thought to be generated by the cortex that represents the stimulus. The vMMN response to visual speech stimuli was used in a study of the lateralization of visual speech processing. Previous research suggested that the right posterior temporal cortex has specialization for processing simple non-speech face gestures, and the left posterior temporal cortex has specialization for processing visual speech gestures. Here, visual speech consonant-vowel (CV stimuli with controlled perceptual dissimilarities were presented in an electroencephalography (EEG vMMN paradigm. The vMMNs were obtained using the comparison of event-related potentials (ERPs for separate CVs in their roles as deviant versus their roles as standard. Four separate vMMN contrasts were tested, two with the perceptually far deviants (i.e., zha or fa and two with the near deviants (i.e., zha or ta. Only far deviants evoked the vMMN response over the left posterior temporal cortex. All four deviants evoked vMMNs over the right posterior temporal cortex. The results are interpreted as evidence that the left posterior temporal cortex represents speech stimuli that are perceived as different consonants, and the right posterior temporal cortex represents face gestures that may not be discriminable as different CVs.

  19. Design Impedance Mismatch Physical Unclonable Functions for IoT Security

    Directory of Open Access Journals (Sweden)

    Xiaomin Zheng

    2017-01-01

    Full Text Available We propose a new design, Physical Unclonable Function (PUF scheme, for the Internet of Things (IoT, which has been suffering from multiple-level security threats. As more and more objects interconnect on IoT networks, the identity of each thing is very important. To authenticate each object, we design an impedance mismatch PUF, which exploits random physical factors of the transmission line to generate a security unique private key. The characteristic impedance of the transmission line and signal transmission theory of the printed circuit board (PCB are also analyzed in detail. To improve the reliability, current feedback amplifier (CFA method is applied on the PUF. Finally, the proposed scheme is implemented and tested. The measure results show that impedance mismatch PUF provides better unpredictability and randomness.

  20. Maximum Likelihood A Priori Knowledge Interpolation-Based Handset Mismatch Compensation for Robust Speaker Identification

    Institute of Scientific and Technical Information of China (English)

    LIAO Yuanfu; ZHUANG Zhixian; YANG Jyhher

    2008-01-01

    Unseen handset mismatch is the major source of performance degradation in speaker identifica-tion in telecommunication environments.To alleviate the problem,a maximum likelihood a priori knowledge interpolation (ML-AKI)-based handset mismatch compensation approach is proposed.It first collects a set of handset characteristics of seen handsets to use as the a priori knowledge for representing the space of handsets.During evaluation the characteristics of an unknown test handset are optimally estimated by in-terpolation from the set of the a pdod knowledge.Experimental results on the HTIMIT database show that the ML-AKI method can improve the average speaker identification rate from 60.0% to 74.6% as compared with conventional maximum a posteriori-adapted Gaussian mixture models.The proposed ML-AKI method is a promising method for robust speaker identification.

  1. Applying different equations to evaluate the level of mismatch between students and school furniture.

    Science.gov (United States)

    Castellucci, H I; Arezes, P M; Molenbroek, J F M

    2014-07-01

    The mismatch between students and school furniture is likely to result in a number of negative effects, such as uncomfortable body posture, pain, and ultimately, it may also affect the learning process. This study's main aim is to review the literature describing the criteria equations for defining the mismatch between students and school furniture, to apply these equations to a specific sample and, based on the results, to propose a methodology to evaluate school furniture suitability. The literature review comprises one publications database, which was used to identify the studies carried out in the field of the abovementioned mismatch. The sample used for testing the different equations was composed of 2261 volunteer subjects from 14 schools. Fifteen studies were found to meet the criteria of this review and 21 equations to test 6 furniture dimensions were identified. Regarding seat height, there are considerable differences between the two most frequently used equations. Although seat to desk clearance was evaluated by knee height, this condition seems to be based on the false assumption that students are sitting on a chair with a proper seat height. Finally, the proposed methodology for suitability evaluation of school furniture should allow for a more reliable analysis of school furniture.

  2. Single-Cylinder Engine Tests of Porous Chrome-Plated Cylinder Barrels with Special Bore Coatings for Radial Air-Cooled Engines

    Science.gov (United States)

    1946-01-01

    sulphamate solution at room temperature having a hydrogen-ion concentration of 1.5. The cylinder was plated for 2 minutes with a current density of 40...for any metal combination (reference 3), engine friction may be reduced somewhat by the use of a silver overplate as a bearing material on the...Cooled Engines. NACA ARR No. E5L18, 1945. 3. Hoyt, Samuel L.: Metals and Alloys Data Book. Reinhold Pub. Corp., 1943, p. 281. 4. Downing, B. F

  3. Liquid-Cooled Garment

    Science.gov (United States)

    1977-01-01

    A liquid-cooled bra, offshoot of Apollo moon suit technology, aids the cancer-detection technique known as infrared thermography. Water flowing through tubes in the bra cools the skin surface to improve resolution of thermograph image.

  4. Effects of Emotional Intelligence on the Impression of Irony Created by the Mismatch between Verbal and Nonverbal Cues.

    Science.gov (United States)

    Jacob, Heike; Kreifelts, Benjamin; Nizielski, Sophia; Schütz, Astrid; Wildgruber, Dirk

    2016-01-01

    Emotional information is conveyed through verbal and nonverbal signals, with nonverbal cues often being considered the decisive factor in the judgment of others' emotional states. The aim of the present study was to examine how verbal and nonverbal cues are integrated by perceivers. More specifically, we tested whether the mismatch between verbal and nonverbal information was perceived as an expression of irony. Moreover, we investigated the effects of emotional intelligence on the impression of irony. The findings revealed that the mismatch between verbal and nonverbal information created the impression of irony. Furthermore, participants higher in emotional intelligence were faster at rating such stimuli as ironic expressions.

  5. Influence of the Strength Mismatch of a Narrow Gap Welded Joint of SA508 on the Plastic η Factor

    Science.gov (United States)

    Koo, J. M.; Huh, Y.; Seok, C. S.

    2012-11-01

    In this article, the influence of the strength mismatch of a narrow gap welded joint of SA508 on the η factor was evaluated. The η factor is the principal parameter that determines the plastic portion of the J-integral. The specimens for tensile and hardness tests were collected from piping with narrow gap welding and the stress-strain curve and hardness were obtained from those. From these results, the Ramberg-Osgood (R-O) constant was obtained. Also, the finite element analysis was performed with variations in the strength mismatch and the weld width. The η factor equation considering the strength mismatch and the weld width of a narrow gap welded joint was suggested.

  6. Component testing of a ground based gas turbine steam cooled rich-burn primary zone combustor for emissions control of nitrogeneous fuels

    Science.gov (United States)

    Schultz, D. F.

    1986-01-01

    This effort summarizes the work performed on a steam cooled, rich-burn primary zone, variable geometry combustor designed for combustion of nitrogeneous fuels such as heavy oils or synthetic crude oils. The steam cooling was employed to determine its feasibility and assess its usefulness as part of a ground based gas turbine bottoming cycle. Variable combustor geometry was employed to demonstrate its ability to control primary and secondary zone equivalence ratios and overall pressure drop. Both concepts proved to be highly successful in achieving their desired objectives. The steam cooling reduced peak liner temperatures to less than 800 K. This low temperature offers the potential of both long life and reduced use of strategic materials for liner fabrication. These degrees of variable geometry were successfully employed to control air flow distribution within the combustor. A variable blade angle axial flow air swirler was used to control primary zone air flow, while the secondary and tertiary zone air flows were controlled by rotating bands which regulated air flow to the secondary zone quench holes and the dilutions holes respectively.

  7. The (Mis)Match between supply and demand labor systems in Kosovo on employability skills: The moderating effects of personal attributes in transition to employment

    OpenAIRE

    Bujar Gallopeni

    2013-01-01

    This study addresses the mismatch between labor supply and labor demand in Kosovo and how this is related to employability skills. Self-report questionnaires were used for collecting data from two groups of respondents, employees and employers, in order to consider both sides of the labor. The within and between groups analyses were conducted using paired sample t-test in the level of skills acquisition and skills requirement. Results indicate that there is a mismatch between labor supply and...

  8. Data center cooling system

    Energy Technology Data Exchange (ETDEWEB)

    Chainer, Timothy J; Dang, Hien P; Parida, Pritish R; Schultz, Mark D; Sharma, Arun

    2015-03-17

    A data center cooling system may include heat transfer equipment to cool a liquid coolant without vapor compression refrigeration, and the liquid coolant is used on a liquid cooled information technology equipment rack housed in the data center. The system may also include a controller-apparatus to regulate the liquid coolant flow to the liquid cooled information technology equipment rack through a range of liquid coolant flow values based upon information technology equipment temperature thresholds.

  9. Mismatch repair balances leading and lagging strand DNA replication fidelity.

    Directory of Open Access Journals (Sweden)

    Scott A Lujan

    Full Text Available The two DNA strands of the nuclear genome are replicated asymmetrically using three DNA polymerases, α, δ, and ε. Current evidence suggests that DNA polymerase ε (Pol ε is the primary leading strand replicase, whereas Pols α and δ primarily perform lagging strand replication. The fact that these polymerases differ in fidelity and error specificity is interesting in light of the fact that the stability of the nuclear genome depends in part on the ability of mismatch repair (MMR to correct different mismatches generated in different contexts during replication. Here we provide the first comparison, to our knowledge, of the efficiency of MMR of leading and lagging strand replication errors. We first use the strand-biased ribonucleotide incorporation propensity of a Pol ε mutator variant to confirm that Pol ε is the primary leading strand replicase in Saccharomyces cerevisiae. We then use polymerase-specific error signatures to show that MMR efficiency in vivo strongly depends on the polymerase, the mismatch composition, and the location of the mismatch. An extreme case of variation by location is a T-T mismatch that is refractory to MMR. This mismatch is flanked by an AT-rich triplet repeat sequence that, when interrupted, restores MMR to > 95% efficiency. Thus this natural DNA sequence suppresses MMR, placing a nearby base pair at high risk of mutation due to leading strand replication infidelity. We find that, overall, MMR most efficiently corrects the most potentially deleterious errors (indels and then the most common substitution mismatches. In combination with earlier studies, the results suggest that significant differences exist in the generation and repair of Pol α, δ, and ε replication errors, but in a generally complementary manner that results in high-fidelity replication of both DNA strands of the yeast nuclear genome.

  10. Mismatch-mediated error prone repair at the immunoglobulin genes.

    Science.gov (United States)

    Chahwan, Richard; Edelmann, Winfried; Scharff, Matthew D; Roa, Sergio

    2011-12-01

    The generation of effective antibodies depends upon somatic hypermutation (SHM) and class-switch recombination (CSR) of antibody genes by activation induced cytidine deaminase (AID) and the subsequent recruitment of error prone base excision and mismatch repair. While AID initiates and is required for SHM, more than half of the base changes that accumulate in V regions are not due to the direct deamination of dC to dU by AID, but rather arise through the recruitment of the mismatch repair complex (MMR) to the U:G mismatch created by AID and the subsequent perversion of mismatch repair from a high fidelity process to one that is very error prone. In addition, the generation of double-strand breaks (DSBs) is essential during CSR, and the resolution of AID-generated mismatches by MMR to promote such DSBs is critical for the efficiency of the process. While a great deal has been learned about how AID and MMR cause hypermutations and DSBs, it is still unclear how the error prone aspect of these processes is largely restricted to antibody genes. The use of knockout models and mice expressing mismatch repair proteins with separation-of-function point mutations have been decisive in gaining a better understanding of the roles of each of the major MMR proteins and providing further insight into how mutation and repair are coordinated. Here, we review the cascade of MMR factors and repair signals that are diverted from their canonical error free role and hijacked by B cells to promote genetic diversification of the Ig locus. This error prone process involves AID as the inducer of enzymatically-mediated DNA mismatches, and a plethora of downstream MMR factors acting as sensors, adaptors and effectors of a complex and tightly regulated process from much of which is not yet well understood.

  11. Testing and numerical simulation of natural draft cooling tower%自然通风冷却塔运行实测与模拟

    Institute of Scientific and Technical Information of China (English)

    胡天乐; 谢晓云; 江亿

    2016-01-01

    Through practical measurement on a natural draft cooling tower in a 150 MW unit,the efficiency and coefficient of heat and mass transfer in the tower were obtained,and several problems during the tower operation and its performance optimization direction were found.On this basis,the temperature and pres-sure distribution in rain area and filling area of the cooling tower were numerically simulated.The results show that,with the filling material thickness of 3.0 m inside the cooling tower,42.1% temperature drop needs 55.8% pressure loss,and the optimum thickness of the padding is around 2.5 m.The optimum oper-ation strategy of this circulating cooling water pump is one pump with two towers,and the wet bulb effi-ciency of the cooling tower can reach 75.0%,the net power generation can increase by 3.007 MW com-pared with the unit using two pumps with one tower strategy.%通过对某150 MW机组的自然通风冷却塔进行实际测试,得到该冷却塔的热质交换效率与系数,并发现其运行过程中的一些问题及性能优化方向;基于此,采用微元差分法对该冷却塔的雨区和填料区进行温度及压力分布的数值模拟.结果表明:在该冷却塔的填料厚度为3.0 m时,其仅贡献42.1%的温降却需要损耗55.8%的空气压降,冷却塔最优填料厚度约为2.5 m;该机组的最优循环冷却水泵运行策略为1泵拖2塔,此时冷却塔的湿球效率可达75.0%,机组净发电量比其他循环冷却水泵运行策略多3.007 MW.

  12. Stochastic cooling in RHIC

    Energy Technology Data Exchange (ETDEWEB)

    Brennan,J.M.; Blaskiewicz, M. M.; Severino, F.

    2009-05-04

    After the success of longitudinal stochastic cooling of bunched heavy ion beam in RHIC, transverse stochastic cooling in the vertical plane of Yellow ring was installed and is being commissioned with proton beam. This report presents the status of the effort and gives an estimate, based on simulation, of the RHIC luminosity with stochastic cooling in all planes.

  13. 基于状态空间法的大型气候环境实验室热负荷仿真模型%A Climatic Test Laboratory Cooling Capacity Calculation Model Based on Space State Method

    Institute of Scientific and Technical Information of China (English)

    马建军; 刘海燕; 成竹

    2016-01-01

    Objective To establish a thermal-load calculation model applied in large climatic test laboratory, the calculation result will help the design of cooling system.Methods First, every potential thermal source was analyzed. Then thermal calcula-tion method and simulation module for thermal source was founded in Simulink. At last a thermal-load simulation models of cooling capacity dominant was set up and applied in the thermal calculation of chamber cooling process.Results The thermal load calculation models is time efficiency for thermal calculation of large climatic test laboratory and convenient in modules update. Thermal load of large climatic test laboratory during cooling down is larger than 3500 kW, thermal load of the floor is more than 50% of the total thermal load.Conclusion The calculation result will help the design of air-condition system and cooling system, and the optimization of control strategy.%目的:建立可用于大型气候环境实验室初期设计热负荷计算的方法和模型,对实验室的热负荷进行计算,为制冷系统选型提供依据。方法通过分析实验室的组成结构和热负荷来源,基于状态空间法建立各部分的热负荷计算方法,在Simulink中搭建以制冷量为输入参数的实验室热负荷计算仿真模型,对实验室空载降温过程进行仿真。结果该仿真模型可以快速对实验室热负荷进行计算,并且可以方便地增减热负荷模块,实验室在降温过程中热负荷达3500 kW以上,地板结构的热负荷占到了总热负荷50%以上。结论热负荷计算结果可应用于空调系统和制冷系统的设计和选型,以及控制策略的优化。

  14. Laser cooling of solids

    OpenAIRE

    Nemova, Galina

    2009-01-01

    Parallel to advances in laser cooling of atoms and ions in dilute gas phase, which has progressed immensely, resulting in physics Nobel prizes in 1997 and 2001, major progress has recently been made in laser cooling of solids. I compare the physical nature of the laser cooling of atoms and ions with that of the laser cooling of solids. I point out all advantages of this new and very promising area of laser physics. Laser cooling of solids (optical refrigeration) at the present time can be lar...

  15. The Effect of Codon Mismatch on the Protein Translation System.

    Directory of Open Access Journals (Sweden)

    Dinglin Zhang

    Full Text Available Incorrect protein translation, caused by codon mismatch, is an important problem of living cells. In this work, a computational model was introduced to quantify the effects of codon mismatch and the model was used to study the protein translation of Saccharomyces cerevisiae. According to simulation results, the probability of codon mismatch will increase when the supply of amino acids is unbalanced, and the longer is the codon sequence, the larger is the probability for incorrect translation to occur, making the synthesis of long peptide chain difficult. By comparing to simulation results without codon mismatch effects taken into account, the fraction of mRNAs with bound ribosome decrease faster along the mRNAs, making the 5' ramp phenomenon more obvious. It was also found in our work that the premature mechanism resulted from codon mismatch can reduce the proportion of incorrect translation when the amino acid supply is extremely unbalanced, which is one possible source of high fidelity protein synthesis after peptidyl transfer.

  16. HLA Mismatching Strategies for Solid Organ Transplantation - a Balancing Act

    Directory of Open Access Journals (Sweden)

    Andrea A. Zachary

    2016-12-01

    Full Text Available HLA matching provides numerous benefits in organ transplantation including better graft function, fewer rejection episodes, longer graft survival, and the possibility of reduced immunosuppression. Mismatches are attended by more frequent rejection episodes that require increased immunosuppression that, in turn, can increase the risk of infection and malignancy. HLA mismatches also incur the risk of sensitization, which can reduce the opportunity and increase waiting time for a subsequent transplant. However, other factors such as donor age, donor type, and immunosuppression protocol, can affect the benefit derived from matching. Further, finding a well matched donor may not be possible for all patients and usually prolongs waiting time. Strategies to optimize transplantation for patients without a well matched donor should take into account the immunologic barrier represented by different mismatches: what are the least immunogenic mismatches considering the patient’s HLA phenotype; should repeated mismatches be avoided; is the patient sensitized to HLA and, if so, what are the strengths of the patient’s antibodies? This information can then be used to define the HLA type of an immunologically optimal donor and the probability of such a donor occurring. A probability that is considered to be too low, may require expanding the donor population through paired donation or modifying what is acceptable which may require employing treatment to overcome immunologic barriers such as increased immunosuppression or desensitization. Thus, transplantation must strike a balance between the risk associated with waiting for the optimal donor and the risk associated with a less than optimal donor.

  17. Visual mismatch negativity reveals automatic detection of sequential regularity violation

    Directory of Open Access Journals (Sweden)

    Gábor eStefanics

    2011-05-01

    Full Text Available Sequential regularities are abstract rules based on repeating sequences of environmental events, which are useful to make predictions about future events. As the processes underlying visual mismatch negativity (vMMN are sensitive to complex stimulus changes, this event-related potential component, like its auditory counterpart, may be an index of a primitive system of intelligence. Here we tested whether the visual system is capable to detect abstract sequential regularity in unattended stimulus sequences. In our first experiment we investigated the emergence of vMMN and other change-related activity to stimuli violating abstract rules. Red and green disk patterns were delivered in pairs. When in the majority of pairs the colors were identical within the pairs, deviant pairs with different colors for the second member of the pair elicited vMMN. Spatially more extended vMMN responses with longer latency were observed for deviants with 10% compared to 30% probability. In our second experiment utilizing oddball sequences, we tested the emergence of vMMN to violations of a concrete, feature-based rule of a repetition of a standard color. Deviant colors elicited a vMMN response in the oddball sequences. VMMN was larger for the second member of the pair, i.e. after a shorter stimulus onset asynchrony (SOA. This result corresponds to the expected SOA/(vMMN relationship. Our results show that the system underlying vMMN is sensitive to abstract probability rules and this component can be considered as a correlate of violated predictions about the characteristics of environmental events.

  18. Effects of cooling rates on microstructure and microhardness of lead-free Sn-3.5%Ag solders

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    The microstructure and microhardness of Sn-3.5%Ag solders were explored in the cooling rate ranging from 0.08 to 104 K/s.Under rapid cooling condition, the strong kinetic undercooling effect leads to the actual solidification process starting at the temperature lower than the equilibrium eutectic point, and the actual metastable eutectic point shifts to the higher Ag concentration. Hence, the higher the applied cooling rate is, the more the volume fraction of primaryβ-Sn crystal forms. At the same time, the separation of primaryβ-Sn crystal favors restraining the formation of bulk Ag3Sn intermetallic compounds (IMCs) in solder due to the mismatch crystalline orientation relationship, those Ag3Sn phase separating through the eutectic reaction could hardly cling to the primary β-Sn crystal and grow up. Additionally, the Vickers hardness test shows that fineβ-Sn and spherical Ag3Sn phase in the rapidly solidified alloy strongly improves the microhardness of the Sn-3.5%Ag solder.

  19. Match/mismatch between the Mytilus edulis larval supply and seston quality: effect on recruitment.

    Science.gov (United States)

    Toupoint, Nicolas; Gilmore-Solomon, Lisandre; Bourque, François; Myrand, Bruno; Pernet, Fabrice; Olivier, Frédéric; Tremblay, Réjean

    2012-08-01

    We considered Cushing's match/mismatch theory in a heterotrophic environment and hypothesized that settlement and recruitment success in blue mussel are higher when the food supply is rich in polyunsaturated and essential fatty acids (PUFA/EFA). To test this hypothesis, we monitored larval development as well as fatty acid composition in trophic resources during two successive reproductive seasons. The decoupling we found between the presence of competent larvae in the water column and settlement rates strongly suggests that metamorphosis is delayed until conditions are suitable. In both years, the major mussel settlement peak was synchronized with a phytoplanktonic pulse rich in EFA, consisting of a large autotrophic bloom in 2007 and a short but substantial peak of picoeukaryotes in 2008. These results suggest a "trophic settlement trigger" that indirectly affects recruitment by strongly improving the settlement rate. Despite similar larval settlement rates during both years, the lower 2007 recruitment likely resulted from a mismatch with a high lipid-quality trophic resource. The seasonal trophic conditions differed greatly between the two years, with fatty acids profiles reflecting heterotrophic plankton production in 2007 and mostly autotrophic production in 2008. In agreement with Cushing's theory, our results highlight a match/mismatch, related to the food lipid quality rather than food quantity. For the first time, we show that the recruitment in marine bivalves may be dependent on phytoplanktonic pulses characterized by high levels of PUFA.

  20. Compensation strategy to reduce geometry and mechanics mismatches in porous biomaterials built with Selective Laser Melting.

    Science.gov (United States)

    Bagheri, Zahra S; Melancon, David; Liu, Lu; Johnston, R Burnett; Pasini, Damiano

    2016-05-06

    The accuracy of Additive Manufacturing processes in fabricating porous biomaterials is currently limited by their capacity to render pore morphology that precisely matches its design. In a porous biomaterial, a geometric mismatch can result in pore occlusion and strut thinning, drawbacks that can inherently compromise bone ingrowth and severely impact mechanical performance. This paper focuses on Selective Laser Melting of porous microarchitecture and proposes a compensation scheme that reduces the morphology mismatch between as-designed and as-manufactured geometry, in particular that of the pore. A spider web analog is introduced, built out of Ti-6Al-4V powder via SLM, and morphologically characterized. Results from error analysis of strut thickness are used to generate thickness compensation relations expressed as a function of the angle each strut formed with the build plane. The scheme is applied to fabricate a set of three-dimensional porous biomaterials, which are morphologically and mechanically characterized via micro Computed Tomography, mechanically tested and numerically analyzed. For strut thickness, the results show the largest mismatch (60% from the design) occurring for horizontal members, reduces to 3.1% upon application of the compensation. Similar improvement is observed also for the mechanical properties, a factor that further corroborates the merit of the design-oriented scheme here introduced.

  1. Mismatch or allostatic load? Timing of life adversity differentially shapes gray matter volume and anxious temperament

    Science.gov (United States)

    Kuhn, Manuel; Scharfenort, Robert; Schümann, Dirk; Schiele, Miriam A.; Münsterkötter, Anna L.; Deckert, Jürgen; Domschke, Katharina; Haaker, Jan; Kalisch, Raffael; Pauli, Paul; Reif, Andreas; Romanos, Marcel; Zwanzger, Peter

    2016-01-01

    Traditionally, adversity was defined as the accumulation of environmental events (allostatic load). Recently however, a mismatch between the early and the later (adult) environment (mismatch) has been hypothesized to be critical for disease development, a hypothesis that has not yet been tested explicitly in humans. We explored the impact of timing of life adversity (childhood and past year) on anxiety and depression levels (N = 833) and brain morphology (N = 129). Both remote (childhood) and proximal (recent) adversities were differentially mirrored in morphometric changes in areas critically involved in emotional processing (i.e. amygdala/hippocampus, dorsal anterior cingulate cortex, respectively). The effect of adversity on affect acted in an additive way with no evidence for interactions (mismatch). Structural equation modeling demonstrated a direct effect of adversity on morphometric estimates and anxiety/depression without evidence of brain morphology functioning as a mediator. Our results highlight that adversity manifests as pronounced changes in brain morphometric and affective temperament even though these seem to represent distinct mechanistic pathways. A major goal of future studies should be to define critical time periods for the impact of adversity and strategies for intervening to prevent or reverse the effects of adverse childhood life experiences. PMID:26568620

  2. ATLAS' major cooling project

    CERN Multimedia

    2005-01-01

    In 2005, a considerable effort has been put into commissioning the various units of ATLAS' complex cryogenic system. This is in preparation for the imminent cooling of some of the largest components of the detector in their final underground configuration. The liquid helium and nitrogen ATLAS refrigerators in USA 15. Cryogenics plays a vital role in operating massive detectors such as ATLAS. In many ways the liquefied argon, nitrogen and helium are the life-blood of the detector. ATLAS could not function without cryogens that will be constantly pumped via proximity systems to the superconducting magnets and subdetectors. In recent weeks compressors at the surface and underground refrigerators, dewars, pumps, linkages and all manner of other components related to the cryogenic system have been tested and commissioned. Fifty metres underground The helium and nitrogen refrigerators, installed inside the service cavern, are an important part of the ATLAS cryogenic system. Two independent helium refrigerators ...

  3. Questioning the role of phenology shifts and trophic mismatching in a planktonic food web

    Science.gov (United States)

    Atkinson, Angus; Harmer, Rachel A.; Widdicombe, Claire E.; McEvoy, Andrea J.; Smyth, Tim J.; Cummings, Denise G.; Somerfield, Paul J.; Maud, Jacqueline L.; McConville, Kristian

    2015-09-01

    In a warming climate, differential shifts in the seasonal timing of predators and prey have been suggested to lead to trophic "mismatches" that decouple primary, secondary and tertiary production. We tested this hypothesis using a 25-year time-series of weekly sampling at the Plymouth L4 site, comparing 57 plankton taxa spanning 4 trophic levels. During warm years, there was a weak tendency for earlier timings of spring taxa and later timings of autumn taxa. While this is in line with many previous findings, numerous exceptions existed and only a few taxa (e.g. Gyrodinium spp., Pseudocalanus elongatus, and Acartia clausi) showed consistent, strong evidence for temperature-related timing shifts, revealed by all 4 of the timing indices that we used. Also, the calculated offsets in timing (i.e. "mismatches") between predator and prey were no greater in extreme warm or cold years than during more average years. Further, the magnitude of these offsets had no effect on the "success" of the predator, in terms of their annual mean abundance or egg production rates. Instead numerous other factors override, including: inter-annual variability in food quantity, high food baseline levels, turnover rates and prolonged seasonal availability, allowing extended periods of production. Furthermore many taxa, notably meroplankton, increased well before the spring bloom. While theoretically a chronic mismatch, this likely reflects trade-offs for example in predation avoidance. Various gelatinous taxa (Phaeocystis, Noctiluca, ctenophores, appendicularians, medusae) may have reduced these predation constraints, with variable, explosive population outbursts likely responding to improved conditions. The match-mismatch hypothesis may apply for highly seasonal, pulsed systems or specialist feeders, but we suggest that the concept is being over-extended to other marine systems where multiple factors compensate.

  4. Climate warming, ecological mismatch at arrival and population decline in migratory birds

    Science.gov (United States)

    Saino, Nicola; Ambrosini, Roberto; Rubolini, Diego; von Hardenberg, Jost; Provenzale, Antonello; Hüppop, Kathrin; Hüppop, Ommo; Lehikoinen, Aleksi; Lehikoinen, Esa; Rainio, Kalle; Romano, Maria; Sokolov, Leonid

    2011-01-01

    Climate is changing at a fast pace, causing widespread, profound consequences for living organisms. Failure to adjust the timing of life-cycle events to climate may jeopardize populations by causing ecological mismatches to the life cycle of other species and abiotic factors. Population declines of some migratory birds breeding in Europe have been suggested to depend on their inability to adjust migration phenology so as to keep track of advancement of spring events at their breeding grounds. In fact, several migrants have advanced their spring arrival date, but whether such advancement has been sufficient to compensate for temporal shift in spring phenophases or, conversely, birds have become ecologically mismatched, is still an unanswered question, with very few exceptions. We used a novel approach based on accumulated winter and spring temperatures (degree-days) as a proxy for timing of spring biological events to test if the progress of spring at arrival to the breeding areas by 117 European migratory bird species has changed over the past five decades. Migrants, and particularly those wintering in sub-Saharan Africa, now arrive at higher degree-days and may have therefore accumulated a ‘thermal delay’, thus possibly becoming increasingly mismatched to spring phenology. Species with greater ‘thermal delay’ have shown larger population decline, and this evidence was not confounded by concomitant ecological factors or by phylogenetic effects. These findings provide general support to the largely untested hypotheses that migratory birds are becoming ecologically mismatched and that failure to respond to climate change can have severe negative impacts on their populations. The novel approach we adopted can be extended to the analysis of ecological consequences of phenological response to climate change by other taxa. PMID:20861045

  5. Efficient energy storage in liquid desiccant cooling systems

    Energy Technology Data Exchange (ETDEWEB)

    Hublitz, Astrid

    2008-07-18

    Liquid Desiccant Cooling Systems (LDCS) are open loop sorption systems for air conditioning that use a liquid desiccant such as a concentrated salt solution to dehumidify the outside air and cool it by evaporative cooling. Thermochemical energy storage in the concentrated liquid desiccant can bridge power mismatches between demand and supply. Low-flow LDCS provide high energy storage capacities but are not a state-of-the-art technology yet. The key challenge remains the uniform distribution of the liquid desiccant on the heat and mass transfer surfaces. The present research analyzes the factors of influence on the energy storage capacity by simulation of the heat and mass transfer processes and specifies performance goals for the distribution of the process media. Consequently, a distribution device for the liquid desiccant is developed that reliably meets the performance goals. (orig.)

  6. Bilayer thickness mismatch controls domain size in biomimetic membranes

    Science.gov (United States)

    Heberle, Frederick A.; Petruzielo, Robin S.; Pan, Jianjun; Drazba, Paul; Kučerka, Norbert; Standaert, Robert F.; Feigenson, Gerald W.; Katsara, John

    2013-03-01

    In order to promote functionality, cells may alter the spatial organization of membrane lipids and proteins, including separation of liquid phases into distinct domains. In model membranes, domain size and morphology depend strongly on composition and temperature, but the physicochemical mechanisms controlling them are poorly understood. Theoretical work suggests a role for interfacial energy at domain boundaries, which may be driven in part by thickness mismatch between a domain and its surrounding bilayer. However, no direct evidence linking thickness mismatch to domain size in free-standing bilayers has been reported. We describe the use of Small Angle Neutron Scattering (SANS) to detect domains in simplified lipid-only models that mimic the composition of plasma membrane. We find that domain size is controlled by the degree of acyl chain unsaturation of low-melting temperature lipids, and that this size transition is correlated to changes in the thickness mismatch between coexisting liquid phases.

  7. Hydrophobic mismatch sorts SNARE proteins into distinct membrane domains

    Science.gov (United States)

    Milovanovic, Dragomir; Honigmann, Alf; Koike, Seiichi; Göttfert, Fabian; Pähler, Gesa; Junius, Meike; Müllar, Stefan; Diederichsen, Ulf; Janshoff, Andreas; Grubmüller, Helmut; Risselada, Herre J.; Eggeling, Christian; Hell, Stefan W.; van den Bogaart, Geert; Jahn, Reinhard

    2015-01-01

    The clustering of proteins and lipids in distinct microdomains is emerging as an important principle for the spatial patterning of biological membranes. Such domain formation can be the result of hydrophobic and ionic interactions with membrane lipids as well as of specific protein-protein interactions. Here using plasma membrane-resident SNARE proteins as model, we show that hydrophobic mismatch between the length of transmembrane domains (TMDs) and the thickness of the lipid membrane suffices to induce clustering of proteins. Even when the TMDs differ in length by only a single residue, hydrophobic mismatch can segregate structurally closely homologous membrane proteins in distinct membrane domains. Domain formation is further fine-tuned by interactions with polyanionic phosphoinositides and homo and heterotypic protein interactions. Our findings demonstrate that hydrophobic mismatch contributes to the structural organization of membranes.

  8. Dynamic-mismatch mapping for digitally-assisted DACs

    CERN Document Server

    Tang, Yongjian; van Roermund, Arthur

    2013-01-01

    This book describes a novel digital calibration technique called dynamic-mismatch mapping (DMM) to improve the performance of digital to analog converters (DACs).  Compared to other techniques, the DMM technique has the advantage of calibrating all mismatch errors without any noise penalty, which is particularly useful in order to meet the demand for high performance DACs in rapidly developing applications, such as multimedia and communication systems.   ·         Discusses fundamental performance limitations of digital to analog converters and summarizes existing design/calibration techniques; ·         Introduces a novel digital calibration technique, called dynamic-mismatch mapping (DMM) to improve both static and dynamic performance of DACs; ·         Includes two state-of-the-art DAC design examples with in-depth discussion.

  9. Determining the functional significance of mismatch repair gene missense variants using biochemical and cellular assays

    DEFF Research Database (Denmark)

    Heinen, Christopher D; Juel Rasmussen, Lene

    2012-01-01

    provided an important experimental tool for studying the functional consequences of VUS. However, beyond this repair assay, a number of other experimental methods have been developed that allow us to test the effect of a VUS on discrete biochemical steps or other aspects of MMR function. Here, we describe......ABSTRACT: With the discovery that the hereditary cancer susceptibility disease Lynch syndrome (LS) is caused by deleterious germline mutations in the DNA mismatch repair (MMR) genes nearly 20 years ago, genetic testing can now be used to diagnose this disorder in patients. A definitive diagnosis...

  10. The Distances to Open Clusters from Main-Sequence Fitting. V. Extension of Color Calibration and Test using Cool and Metal-Rich Stars in NGC 6791

    CERN Document Server

    An, Deokkeun; Pinsonneault, Marc H; Lee, Jae-Woo

    2015-01-01

    We extend our effort to calibrate stellar isochrones in the Johnson-Cousins ($BVI_C$) and the 2MASS ($JHK_s$) filter systems based on observations of well-studied open clusters. Using cool main-sequence (MS) stars in Praesepe, we define empirical corrections to the Lejeune et al. color-effective temperature ($T_{\\rm eff}$) relations down to $T_{\\rm eff} \\sim 3600$ K, complementing our previous work based on the Hyades and the Pleiades. We apply empirically corrected isochrones to existing optical and near-infrared photometry of cool ($T_{\\rm eff} \\leq 5500$ K) and metal-rich ([Fe/H]$=+0.37$) MS stars in NGC 6791. The current methodology relies on an assumption that color-$T_{\\rm eff}$ corrections are independent of metallicity, but we find that estimates of color-excess and distance from color-magnitude diagrams with different color indices converge on each other at the precisely known metallicity of the cluster. Along with a satisfactory agreement with eclipsing binary data in the cluster, we view the improv...

  11. Potenciales evocados cognitivos: Utilidad de la mismatch negativity Cognitive evoked potentials: Perspectives for mismatch negativity

    Directory of Open Access Journals (Sweden)

    I.G. Gurtubay

    2009-01-01

    Full Text Available Las técnicas de potenciales evocados cognitivos están consideradas como largas y técnicamente complejas, por ello a pesar de su potencial utilidad, su uso en la práctica clínica no está muy extendida. Los recientes avances en el registro, análisis y mejoras en el software de manejo de estas señales, han reducido notablemente estos problemas. De entre todos los potenciales cognitivos es la Mismatch negativity, la que por sus especiales características en cuanto a requisitos de generación y probada utilidad clínica, destaca como la más prometedora. La capacidad de ser generada sin requerimientos atencionales la hace especialmente útil para la valoración de sujetos con bajo nivel de conciencia, sirviendo entre otras cosas, para predecir el despertar del coma. La incorporación de dicha técnica a la batería de técnicas neurofisiológicas que valoran el estado de estos sujetos va suponer una mejora sustancial en la evaluación de casos cuyo manejo en la práctica clínica es sumamente complejo.The techniques of cognitive evoked potentials are considered long and technically complex, which is why their use in clinical practice is not very widespread in spite of their potential utility. Recent advances in registering and analysis, together with improvement of the software managing these signals, have appreciably reduced these problems. Mismatch negativity stands out as the most promising of all the cognitive potentials due to its special characteristics regarding its generation requisites and its proven clinical utility. The fact that it can be generated without care requirements makes it especially useful for evaluating subjects with a low level of consciousness; it serves for predicting when they will emerge from a coma, amongst other uses. The incorporation of this technique into the arsenal of neurophysiological techniques for evaluating the state of these subjects will bring a substantial improvement in the evaluation of cases

  12. 螺旋管圈水冷壁鳍片焊缝专用超声检测技术%The Special Ultrasonic Testing Technology for Fins Weld of Spiral Water Cooled Wall Tube

    Institute of Scientific and Technical Information of China (English)

    严祯荣; 陈学东; 罗晓明

    2015-01-01

    针对螺旋管圈水冷壁鳍片焊缝裂纹的产生特性,开发了专用微型超声波检测探头和超声波检测仪器。在刻有近似鳍片裂纹和平底孔的螺旋管圈水冷壁试件上进行了验证性检测试验。在鳍片宽度仅5 mm 的狭长检测空间,通过鳍片单一面耦合,实现了双面鳍片焊缝缺陷检测,能够方便、有效地应用到超超临界锅炉螺旋管圈水冷壁检修环节。%For features of fins crack initiation of spiral water cooled wall tube,a special miniature ultrasonic probe and ultrasonic testing instrument were developed.The confirmatory tests were carried out on specimen of spiral water cooled wall tube,which were engraved with the approximate fins weld crack and flat bottom holes.The confirmatory tests have realized detection of the double fins weld defect in the long and narrow space detection of the only 5 mm fin width,through the fins of the single surface coupling,which can be conveniently and effectively applied to the overhaul of spiral water cooled wall tube of ultra supercritical boiler.

  13. Stochastic cooling in RHIC

    Energy Technology Data Exchange (ETDEWEB)

    Brennan J. M.; Blaskiewicz, M.; Mernick, K.

    2012-05-20

    The full 6-dimensional [x,x'; y,y'; z,z'] stochastic cooling system for RHIC was completed and operational for the FY12 Uranium-Uranium collider run. Cooling enhances the integrated luminosity of the Uranium collisions by a factor of 5, primarily by reducing the transverse emittances but also by cooling in the longitudinal plane to preserve the bunch length. The components have been deployed incrementally over the past several runs, beginning with longitudinal cooling, then cooling in the vertical planes but multiplexed between the Yellow and Blue rings, next cooling both rings simultaneously in vertical (the horizontal plane was cooled by betatron coupling), and now simultaneous horizontal cooling has been commissioned. The system operated between 5 and 9 GHz and with 3 x 10{sup 8} Uranium ions per bunch and produces a cooling half-time of approximately 20 minutes. The ultimate emittance is determined by the balance between cooling and emittance growth from Intra-Beam Scattering. Specific details of the apparatus and mathematical techniques for calculating its performance have been published elsewhere. Here we report on: the method of operation, results with beam, and comparison of results to simulations.

  14. Neighboring extremal optimal control design including model mismatch errors

    Energy Technology Data Exchange (ETDEWEB)

    Kim, T.J. [Sandia National Labs., Albuquerque, NM (United States); Hull, D.G. [Texas Univ., Austin, TX (United States). Dept. of Aerospace Engineering and Engineering Mechanics

    1994-11-01

    The mismatch control technique that is used to simplify model equations of motion in order to determine analytic optimal control laws is extended using neighboring extremal theory. The first variation optimal control equations are linearized about the extremal path to account for perturbations in the initial state and the final constraint manifold. A numerical example demonstrates that the tuning procedure inherent in the mismatch control method increases the performance of the controls to the level of a numerically-determined piecewise-linear controller.

  15. Advanced radar detection schemes under mismatched signal models

    CERN Document Server

    Bandiera, Francesco

    2009-01-01

    Adaptive detection of signals embedded in correlated Gaussian noise has been an active field of research in the last decades. This topic is important in many areas of signal processing such as, just to give some examples, radar, sonar, communications, and hyperspectral imaging. Most of the existing adaptive algorithms have been designed following the lead of the derivation of Kelly's detector which assumes perfect knowledge of the target steering vector. However, in realistic scenarios, mismatches are likely to occur due to both environmental and instrumental factors. When a mismatched signal

  16. Sub-recoil cooling up to nano-Kelvin. Direct measurement of spatial coherency length. New tests for Levy statistics; Refroidissement laser subrecul au nanokelvin. Mesure directe de la longueur de coherence spatiale. Nouveaux tests des statistiques de Levy

    Energy Technology Data Exchange (ETDEWEB)

    Saubamea, B

    1998-12-15

    This thesis presents a new method to measure the temperature of ultracold atoms from the spatial autocorrelation function of the atomic wave-packets. We thus determine the temperature of metastable helium-4 atoms cooled by velocity selective dark resonance, a method known to cool the atoms below the temperature related to the emission or the absorption of a single photon by an atom at rest, namely the recoil temperature. This cooling mechanism prepares each atom in a coherent superposition of two wave-packets with opposite mean momenta, which are initially superimposed and then drift apart. By measuring the temporal decay of their overlap, we have access to the Fourier transform of the momentum distribution of the atoms. Using this method, we can measure temperatures as low as 5 nK, 800 times as small as the recoil temperature. Moreover we study in detail the exact shape of the momentum distribution and compare the experimental results with two different theoretical approaches: a quantum Monte Carlo simulation and an analytical model based on Levy statistics. We compare the calculated line shape with the one deduced from simulations, and each theoretical model with experimental data. A very good agreement is found with each approach. We thus demonstrate the validity of the statistical model of sub-recoil cooling and give the first experimental evidence of some of its characteristics: the absence of steady-state, the self-similarity and the non Lorentzian shape of the momentum distribution of the cooled atoms. All these aspects are related to the non ergodicity of sub-recoil cooling. (author)

  17. The MICE Demonstration of Ionization Cooling

    Energy Technology Data Exchange (ETDEWEB)

    Pasternak, J.; Blackmore, V.; Hunt, C.; Lagrange, J-B.; Long, K.; Collomb, N.; Snopok, P.

    2015-05-01

    Muon beams of low emittance provide the basis for the intense, well-characterised neutrino beams necessary to elucidate the physics of flavour at the Neutrino Factory and to provide lepton-antilepton collisions at energies of up to several TeV at the Muon Collider. The International Muon Ionization Cooling Experiment (MICE) will demonstrate ionization cooling, the technique by which it is proposed to reduce the phase-space volume occupied by the muon beam at such facilities. In an ionization cooling channel, the muon beam passes through a material (the absorber) in which it loses energy. The energy lost is then replaced using RF cavities. The combined effect of energy loss and re-acceleration is to reduce the transverse emittance of the beam (transverse cooling). A major revision of the scope of the project was carried out over the summer of 2014. The revised project plan, which has received the formal endorsement of the international MICE Project Board and the international MICE Funding Agency Committee, will deliver a demonstration of ionization cooling by September 2017. In the revised configuration a central lithium-hydride absorber provides the cooling effect. The magnetic lattice is provided by the two superconducting focus coils and acceleration is provided by two 201 MHz single-cavity modules. The phase space of the muons entering and leaving the cooling cell will be measured by two solenoidal spectrometers. All the superconducting magnets for the ionization cooling demonstration are available at the Rutherford Appleton Laboratory and the first single-cavity prototype is under test in the MuCool Test Area at Fermilab. The design of the cooling demonstration experiment will be described together with a summary of the performance of each of its components. The cooling performance of the revised configuration will also be presented.

  18. Load shift control schemes for residential cooling devices. Results of a field test; Ergebnisse eines Feldtests zum oszillationsfreien Lastmanagement von Kuehl-/Gefriergeraeten in Privathaushalten auf Basis von Temperaturvorgaben

    Energy Technology Data Exchange (ETDEWEB)

    Hinrichs, Christian [Oldenburg Univ. (Germany); Luensdorf, Ontje; Sonnenschein, Michael [OFFIS Institut fuer Informatik, Oldenburg (Germany); Loewenstein, Claas [EWE AG, Oldenburg (Germany)

    2012-07-01

    Due to the increasing integration of renewable energy resources with fluctuating feed-in of electrical power, the use of flexible loads in energy management systems gains more and more interest lately. However, because of technical restrictions, direct control of the power consumption of such appliances is usually not feasible. The contribution at hand presents a control mechanism for domestic cooling devices, which is based on temperature set points and thus can be realized using standard comfort functions. The proposed mechanism is able to actively reverse synchronizations of device states, and hence prevents oscillations in the resulting load curve. Results of a field test are shown subsequently. (orig.)

  19. Investigations of Air-cooled Turbine Rotors for Turbojet Engines II : Mechanical Design, Stress Analysis, and Burst Test of Modified J33 Split-disk Rotor / Richard H. Kemp and Merland L. Moseson

    Science.gov (United States)

    Kemp, Richard H; Moseson, Merland L

    1952-01-01

    A full-scale J33 air-cooled split turbine rotor was designed and spin-pit tested to destruction. Stress analysis and spin-pit results indicated that the rotor in a J33 turbojet engine, however, showed that the rear disk of the rotor operated at temperatures substantially higher than the forward disk. An extension of the stress analysis to include the temperature difference between the two disks indicated that engine modifications are required to permit operation of the two disks at more nearly the same temperature level.

  20. Experimental investigations on showerhead cooling on a blunt body

    Energy Technology Data Exchange (ETDEWEB)

    Falcoz, C.; Ott, P. [Ecole Polytechnique Federale de Lausanne (EPFL), Laboratoire de Thermique Appliquee et de Turbomachines (LTT), 1015 Lausanne (Switzerland); Weigand, B. [Institut fuer Thermodynamik der Luft- und Raumfahrt (ITLR), Stuttgart University, Pfaffenwaldring 31, 70569 Stuttgart (Germany)

    2006-04-15

    In modern gas turbines, the turbine airfoil leading edge is currently protected from the hot gases by specific film cooling schemes, so-called showerhead cooling. The present paper shows an experimental study of different showerhead cooling geometries on a blunt body. For these tests, TLC (thermochromatic liquid crystals) have been used for measuring the film cooling performance and the heat transfer. Detailed experimental results for the aerodynamics, the film cooling effectiveness and the heat transfer enhancement are presented for different film cooling geometries. (author)

  1. MUTYH and the mismatch repair system: partners in crime?

    Science.gov (United States)

    Niessen, Renée C; Sijmons, Rolf H; Ou, J; Olthof, Sandra G M; Osinga, Jan; Ligtenberg, Marjolijn J; Hogervorst, Frans B L; Weiss, Marjan M; Tops, Carli M J; Hes, Frederik J; de Bock, Geertruida H; Buys, Charles H C M; Kleibeuker, Jan H; Hofstra, Robert M W

    2006-03-01

    Biallelic germline mutations of MUTYH-a gene encoding a base excision repair protein-are associated with an increased susceptibility of colorectal cancer. Whether monoallelic MUTYH mutations also increase cancer risk is not yet clear, although there is some evidence suggesting a slight increase of risk. As the MUTYH protein interacts with the mismatch repair (MMR) system, we hypothesised that the combination of a monoallelic MUTYH mutation with an MMR gene mutation increases cancer risk. We therefore investigated the prevalence of monoallelic MUTYH mutations in carriers of a germline MMR mutation: 40 carriers of a truncating mutation (group I) and 36 of a missense mutation (group II). These patients had been diagnosed with either colorectal or endometrial cancer. We compared their MUTYH mutation frequencies with those observed in a group of 134 Dutch colorectal and endometrial cancer patients without an MMR gene mutation (0.7%) and those reported for Caucasian controls (1.5%). In group I one monoallelic MUTYH mutation was found (2.5%). In group II five monoallelic germline MUTYH mutations were found (14%), four of them in MSH6 missense mutation carriers (20%). Of all patients with an MMR gene mutation, only those with a missense mutation showed a significantly higher frequency of (monoallelic) MUTYH mutations than the Dutch cancer patients without MMR gene mutations (P = 0.002) and the published controls (P = 0.001). These results warrant further study to test the hypothesis of mutations in MMR genes (in particular MSH6) and MUTYH acting together to increase cancer risk.

  2. Effect of aripiprazole on mismatch negativity (MMN in schizophrenia.

    Directory of Open Access Journals (Sweden)

    Zhenhe Zhou

    Full Text Available BACKGROUND: Cognitive deficits are considered core symptoms of the schizophrenia. Cognitive function has been found to be a better predictor of functional outcome than symptom levels. Changed mismatch negativity (MMN reflects abnormalities of early auditory processing in schizophrenia. Up to now, no studies for the effects of aripiprazole on MMN in schizophrenia have been reported. METHODOLOGY/PRINCIPAL FINDINGS: Subjects included 26 patients with schizophrenia, and 26 controls. Psychopathology was rated in patients with the Positive and Negative Syndrome Scale (PANSS at baseline, after 4- and 8-week treatments with aripiprazole. Auditory stimuli for ERP consisted of 100 millisecond/1000 Hz standards, intermixed with 100 millisecond/1500 Hz frequency deviants and 250 millisecond/1000 Hz duration deviants. EEG was recorded at Fz. BESA 5.1.8 was used to perform data analysis. MMN waveforms were obtained by subtracting waveforms elicited by standards from waveforms elicited by frequency- or duration-deviant stimuli. Aripiprazole decreased all PANSS. Patients showed smaller mean amplitudes of frequency and duration MMN at baseline than did controls. A repeated measure ANOVA with sessions (i.e., baseline, 4- and 8-week treatments and MMN type (frequency vs. duration as within-subject factors revealed no significant MMN type or MMN type × session main effect for MMN amplitudes. Session main effect was significant. LSD tests demonstrated significant differences between MMN amplitudes at 8 weeks and those at both baseline and 4 weeks. There was significant negative correlation between changes in amplitudes of frequency and duration MMN and changes in PANSS total scores at baseline and follow-up periods. CONCLUSIONS: Aripiprazole improved the amplitudes of MMN. MMN offers objective evidence that treatment with the aripiprazole may ameliorate preattentive deficits in schizophrenia.

  3. Cooling by Thermodynamic Induction

    Science.gov (United States)

    Patitsas, S. N.

    2017-03-01

    A method is described for cooling conductive channels to below ambient temperature. The thermodynamic induction principle dictates that the electrically biased channel will cool if the electrical conductance decreases with temperature. The extent of this cooling is calculated in detail for both cases of ballistic and conventional transport with specific calculations for carbon nanotubes and conventional metals, followed by discussions for semiconductors, graphene, and metal-insulator transition systems. A theorem is established for ballistic transport stating that net cooling is not possible. For conventional transport, net cooling is possible over a broad temperature range, with the range being size-dependent. A temperature clamping scheme for establishing a metastable nonequilibrium stationary state is detailed and followed with discussion of possible applications to on-chip thermoelectric cooling in integrated circuitry and quantum computer systems.

  4. Cooling by Thermodynamic Induction

    Science.gov (United States)

    Patitsas, S. N.

    2016-11-01

    A method is described for cooling conductive channels to below ambient temperature. The thermodynamic induction principle dictates that the electrically biased channel will cool if the electrical conductance decreases with temperature. The extent of this cooling is calculated in detail for both cases of ballistic and conventional transport with specific calculations for carbon nanotubes and conventional metals, followed by discussions for semiconductors, graphene, and metal-insulator transition systems. A theorem is established for ballistic transport stating that net cooling is not possible. For conventional transport, net cooling is possible over a broad temperature range, with the range being size-dependent. A temperature clamping scheme for establishing a metastable nonequilibrium stationary state is detailed and followed with discussion of possible applications to on-chip thermoelectric cooling in integrated circuitry and quantum computer systems.

  5. Radiant Floor Cooling Systems

    DEFF Research Database (Denmark)

    Olesen, Bjarne W.

    2008-01-01

    In many countries, hydronic radiant floor systems are widely used for heating all types of buildings such as residential, churches, gymnasiums, hospitals, hangars, storage buildings, industrial buildings, and smaller offices. However, few systems are used for cooling.This article describes a floor...... cooling system that includes such considerations as thermal comfort of the occupants, which design parameters will influence the cooling capacity and how the system should be controlled. Examples of applications are presented....

  6. 40 CFR 1065.122 - Engine cooling and lubrication.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Engine cooling and lubrication. 1065.122 Section 1065.122 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... lubrication. (a) Engine cooling. Cool the engine during testing so its intake-air, oil, coolant, block,...

  7. Initial Cooling Experiment (ICE)

    CERN Multimedia

    Photographic Service

    1978-01-01

    In 1977, in a record-time of 9 months, the magnets of the g-2 experiment were modified and used to build a proton/antiproton storage ring: the "Initial Cooling Experiment" (ICE). It served for the verification of the cooling methods to be used for the "Antiproton Project". Stochastic cooling was proven the same year, electron cooling followed later. Also, with ICE the experimental lower limit for the antiproton lifetime was raised by 9 orders of magnitude: from 2 microseconds to 32 hours. For its previous life as g-2 storage ring, see 7405430. More on ICE: 7711282, 7809081, 7908242.

  8. High energy electron cooling

    Energy Technology Data Exchange (ETDEWEB)

    Parkhomchuk, V. [Budker Institute of Nuclear Physics, Novosibirsk (Russian Federation)

    1997-09-01

    High energy electron cooling requires a very cold electron beam. The questions of using electron cooling with and without a magnetic field are presented for discussion at this workshop. The electron cooling method was suggested by G. Budker in the middle sixties. The original idea of the electron cooling was published in 1966. The design activities for the NAP-M project was started in November 1971 and the first run using a proton beam occurred in September 1973. The first experiment with both electron and proton beams was started in May 1974. In this experiment good result was achieved very close to theoretical prediction for a usual two component plasma heat exchange.

  9. Power electronics cooling apparatus

    Science.gov (United States)

    Sanger, Philip Albert; Lindberg, Frank A.; Garcen, Walter

    2000-01-01

    A semiconductor cooling arrangement wherein a semiconductor is affixed to a thermally and electrically conducting carrier such as by brazing. The coefficient of thermal expansion of the semiconductor and carrier are closely matched to one another so that during operation they will not be overstressed mechanically due to thermal cycling. Electrical connection is made to the semiconductor and carrier, and a porous metal heat exchanger is thermally connected to the carrier. The heat exchanger is positioned within an electrically insulating cooling assembly having cooling oil flowing therethrough. The arrangement is particularly well adapted for the cooling of high power switching elements in a power bridge.

  10. Test of different measures for the prevention of scaling in the cooling system of Grohnde nuclear power plant; Test verschiedener Massnahmen zur Verhuetung von Kalkablagerungen im Kuehlsystem des Kernkraftwerks Grohnde

    Energy Technology Data Exchange (ETDEWEB)

    Czolkoss, W. [Taprogge GmbH, Wetter (Germany); Jacobi, G.; Schueler, A. [Gemeinschaftskernkraftwerk Grohnde GmbH, Emmerthal (Germany); Fichte, W. [Allianz-Zentrum fuer Technik GmbH (AZT), Ismaning (Germany)

    2002-07-01

    In the cooling system of the Grohnde Nuclear Power Plant, heavy calcium carbonate precipitations have occurred in the turbine condenser and in the cooling tower since 1994. Those precipitations cause performance losses and high cleaning costs. Reasons for the intensified precipitation are apparently the biologically upgraded water quality of the river Weser, as well as specific operational conditions of the cooling system (partial recirculation of cooling water). It was noticed that the formation of calcium carbonate deposits occurred within a limited period of less than two weeks in May. The calcium precipitation was that strong during this time that it could not be stopped despite the immediate application of corundum cleaning balls in the tube cleaning system. (orig.) [German] Im Kuehlsystem des Kernkraftwerks Grohnde kommt es seit 1994 zu starken Kalkausfaellungen im Turbinenkondensator und im Kuehlturm, die Leistungsverluste und hohe Reinigungskosten verursachen. Das Auftreten der Kalkabscheidungen haengt offensichtlich mit der oekologisch verbesserten Wasserqualitaet der Weser und spezifischen Betriebsbedingungen des Kuehlsystems zusammen. Die Auswertung der Betriebsmessdaten des Kuehlwassers zeigt, dass eine der Ursachen der zeitlich begrenzten, extremen Kalkabscheidung im Kuehlsystem offenbar das Wachstum von Mikroorganismen in der Weser ist, aus der das Kuehlsystem gespeist wird. (orig.)

  11. A research on thermoelectric generator's electrical performance under temperature mismatch conditions for automotive waste heat recovery system

    Directory of Open Access Journals (Sweden)

    Z.B. Tang

    2015-03-01

    Full Text Available The thermoelectric generators recover useful energy by the function of thermoelectric modules which can convert waste heat energy into electricity from automotive exhaust. In the actual operation, the electrical connected thermoelectric modules are operated under temperature mismatch conditions and then the problem of decreased power output causes due to the inhomogeneous temperature gradient distribution on heat exchanger surface. In this case study, an individual module test system and a test bench have been carried out to test and analyze the impact of thermal imbalance on the output electrical power at module and system level. Variability of the temperature difference and clamping pressure are also tested in the individual module measurement. The system level experimental results clearly describe the phenomenon of thermoelectric generator's decreased power output under mismatched temperature condition and limited working temperature. This situation is improved with thermal insulation on the modules and proved to be effective.

  12. High Performance Torso Cooling Garment

    Science.gov (United States)

    Conger, Bruce; Makinen, Janice

    2016-01-01

    The concept proposed in this paper is to improve thermal efficiencies of the liquid cooling and ventilation garment (LCVG) in the torso area, which could facilitate removal of LCVG tubing from the arms and legs, thereby increasing suited crew member mobility. EVA space suit mobility in micro-gravity is challenging, and it becomes even more challenging in the gravity of Mars. By using shaped water tubes that greatly increase the contact area with the skin in the torso region of the body, the heat transfer efficiency can be increased. This increase in efficiency could provide the required liquid cooling via torso tubing only; no arm or leg LCVG tubing would be required. Benefits of this approach include increased crewmember mobility, enhanced evaporation cooling, increased comfort during Mars EVA tasks, and easing of the overly dry condition in the helmet associated with the Advanced Extravehicular Mobility Unit (EMU) ventilation loop currently under development. This report describes analysis and test activities performed to evaluate the potential improvements to the thermal performance of the LCVG. Analyses evaluated potential tube shapes for improving the thermal performance of the LCVG. The analysis results fed into the selection of flat flow strips to improve thermal contact with the skin of the suited test subject. Testing of small segments was performed to compare thermal performance of the tubing approach of the current LCVG to the flat flow strips proposed as the new concept. Results of the testing is presented along with recommendations for future development of this new concept.

  13. Educational Mismatch and Spatial Flexibility in Italian Local Labour Markets

    Science.gov (United States)

    Croce, Giuseppe; Ghignoni, Emanuela

    2015-01-01

    According to recent literature, this paper highlights the relevance of spatial mobility as an explanatory factor of the individual risk of job-education mismatch. To investigate this causal link, we use individual information about daily home-to-work commuting time and choices to relocate in a different local area to get a job. Our model takes…

  14. Responses of Transmembrane Peptide and Lipid Chains to Hydrophobic Mismatch

    Institute of Scientific and Technical Information of China (English)

    YANG Lei; LI Jian-tao; QI Hai-yan; LI Fei

    2012-01-01

    Hydrophobic mismatch between the hydrophobic length of membrane proteins and hydrophobic thickness of membranes is a crucial factor in controlling protein function and assembly.We combined fluorescence with circular dichroism(CD) and attenuated total reflection infrared(ATR-IR) spectroscopic methods to investigate the behaviors of the peptide and lipids under hydrophobic mismatch using a model peptide from the fourth transmembrane domain of natural resistance-associated macrophage protein 1 (Nramp 1),the phosphatidylcholines(PCs) and phosphatidylglycerols(PGs) with different lengths of acyl chains(14:0,16:0 and 18:0).In all PG lipid membranes,the peptide forms stable α-helix structure,and the helix axis is parallel to lipid chains.The helical span and orientation hardly change in varying thickness of PG membranes,while the lipid chains can deform to accommodate to the hydrophobic surface of embedded peptide.By comparison,the helical structures of the model peptide in PC lipid membranes are less stable.Upon incorporation with PC lipid membranes,the peptide can deform itself to accommodate to the hydrophobic thickness of lipid membranes in response to hydrophobic mismatch.In addition,hydrophobic mismatch can increase the aggregation propensity of the peptide in both PC and PG lipid membranes and the peptide in PC membranes has more aggregation tendency than that in PG membranes.

  15. Interplay between quantum confinement and dielectric mismatch for ultrashallow dopants

    NARCIS (Netherlands)

    Mol, J.A.; Salfi, J.; Miwa, J.A.; Simmons, M.Y.; Rogge, S.

    2013-01-01

    Understanding the electronic properties of dopants near an interface is a critical challenge for nanoscale devices. We have determined the effect of dielectric mismatch and quantum confinement on the ionization energy of individual acceptors beneath a hydrogen passivated silicon (100) surface. While

  16. Supply and Demand Mismatches in Training: Can Anything Be Done?

    Science.gov (United States)

    Castro, Claudio de Moura; de Andrade, Antonio Cabral

    1990-01-01

    Vocational training often fails to provide what employers need and students want. To correct supply/demand mismatches requires improving feedback from employers, increasing the flow of information, bringing schools closer to businesses, rewarding institutions for successful employment of graduates, and providing incentives for entrepreneurs. (SK)

  17. Bisimulation Lattice of Asymmetric Chi Calculus with Mismatch

    Institute of Scientific and Technical Information of China (English)

    Dong Xiaoju(董笑菊); Zhong Farong; Fu Yuxi

    2003-01-01

    This paper carries out a systematic investigation into the bisimulation lattice of asymmetric chi calculus with a mismatch combinator. It is shown that all the sixty three L-bisimilarities collapse to twelve distinct relations and they form a bisimulation lattice with respect to set inclusion. The top of the lattice coincides with the barbed bisimilarity.

  18. Understanding the Mismatch Between Coaches' and Players' Perceptions of Exertion

    NARCIS (Netherlands)

    Brink, Michel S.; Kersten, Anna W.; Frencken, Wouter G. P.

    2017-01-01

    A mismatch between the training exertion intended by a coach and the exertion perceived by players is well established in sports. However, it is unknown whether coaches can accurately observe exertion of individual players during training. Furthermore, the discrepancy in coaches' and players' percep

  19. Phase mismatched optical parametric generation in semiconductor magnetoplasma

    Science.gov (United States)

    Dubey, Swati; Ghosh, S.; Jain, Kamal

    2017-05-01

    Optical parametric generation involves the interaction of pump, signal, and idler waves satisfying law of conservation of energy. Phase mismatch parameter plays important role for the spatial distribution of the field along the medium. In this paper instead of exactly matching wave vector, a small mismatch is admitted with a degree of phase velocity mismatch between these waves. Hence the medium must possess certain finite coherence length. This wave mixing process is well explained by coupled mode theory and one dimensional hydrodynamic model. Based on this scheme, expressions for threshold pump field and transmitted intensity have been derived. It is observed that the threshold pump intensity and transmitted intensity can be manipulated by varying doping concentration and magnetic field under phase mismatched condition. A compound semiconductor crystal of n-InSb is assumed to be shined at 77 K by a 10.6μm CO2 laser with photon energy well below band gap energy of the crystal, so that only free charge carrier influence the optical properties of the medium for the I.R. parametric generation in a semiconductor plasma medium. Favorable parameters were explored to incite the said process keeping in mind the cost effectiveness and conversion efficiency of the process.

  20. Diagnostic criteria for constitutional mismatch repair deficiency syndrome

    DEFF Research Database (Denmark)

    Wimmer, Katharina; Kratz, Christian P; Vasen, Hans F A;

    2014-01-01

    Constitutional mismatch repair deficiency (CMMRD) syndrome is a distinct childhood cancer predisposition syndrome that results from biallelic germline mutations in one of the four MMR genes, MLH1, MSH2, MSH6 or PMS2. The tumour spectrum is very broad, including mainly haematological, brain...

  1. DNA mismatch repair: Dr. Jekyll and Mr. Hyde?

    Science.gov (United States)

    Hsieh, Peggy

    2012-09-14

    In this issue, Peña-Diaz et al. (2012) describe a pathway for somatic mutation in nonlymphoid cells termed noncanonical DNA mismatch repair, whereby the error-prone translesion polymerase Pol-η substitutes for high-fidelity replicative polymerases to resynthesize excised regions opposite DNA damage. Copyright © 2012 Elsevier Inc. All rights reserved.

  2. BEPS Action 2: Neutralizing the Effects on Hybrid Mismatch Arrangements

    NARCIS (Netherlands)

    de Boer, R.; Marres, O.

    2015-01-01

    Curbing tax arbitrage is one of the main priorities of the Organization for Economic Cooperation and Development (OECD) (endorsed by the G20 and the G8) ever since the public debate on base erosion fully erupted. Neutralizing the effect of hybrid mismatch arrangements has become Action No. 2 of the

  3. Mismatch of Vocational Graduates: What Penalty on French Labour Market?

    Science.gov (United States)

    Beduwe, Catherine; Giret, Jean-Francois

    2011-01-01

    This study explores individual effects of educational mismatch on wages, job satisfaction and on-the-job-search on French labour market. We distinguish between horizontal matches (job matches with field of studies) and vertical matches (job matches the level of qualification) on the one hand and skills matches (worker's assessment) on the other…

  4. Discriminating DNA mismatches by electrochemical and gravimetric techniques.

    Science.gov (United States)

    Mazouz, Zouhour; Fourati, Najla; Zerrouki, Chouki; Ommezine, Asma; Rebhi, Lamia; Yaakoubi, Nourdin; Kalfat, Rafik; Othmane, Ali

    2013-10-15

    A silicon nitride functionalized electrode and a 104 MHz lithium tantalate (LiTaO₃) surface acoustic wave (SAW) sensor have been used to investigate target-probe recognition processes. Electrochemical and gravimetric measurements have been considered to monitor hybridization of single base mismatch (SBM) in synthetic oligonucleotides and single-nucleotide polymorphisms ApoE in real clinical genotypes. Obvious discrimination of SBM in nucleotides has been shown by both gravimetric and electrochemical techniques, without labeling nor amplification. Investigations on mismatches nature and position have also been considered. For guanine-adenine (GA), guanine-thymine (GT) and guanine-guanine (GG) mismatches, the sensors responses present a dependence upon positions. Considering the capacitance variations and hybridization rates, results showed that gravimetric transduction is more sensitive than electrochemical one. Moreover, the highest value of GT hybridization rate (in the middle position) was found in accordance with the nearest-neighbor model, where the considered configuration appears as the most thermodynamically stable. For the real samples, where the electrochemical transduction, by combining capacitance and flat-band potential measurements, were found more sensitive, the results show that the realized sensor permits an unambiguous discrimination of recognition between fully complementary, non-complementary and single base mismatched targets, and even between the combination of differently matched strands.

  5. Channel normalization technique for speech recognition in mismatched conditions

    CSIR Research Space (South Africa)

    Kleynhans, N

    2008-11-01

    Full Text Available , where one wishes to use any available training data for a variety of purposes. Research into a new channel normalization (CN) technique for channel mismatched speech recognition is presented. A process of inverse linear filtering is used in order...

  6. Resolving Architectural Mismatches of COTS Through Architectural Reconciliation

    NARCIS (Netherlands)

    Avgeriou, Paris; Guelfi, Nicolas

    2005-01-01

    The integration of COTS components into a system under development entails architectural mismatches. These have been tackled, so far, at the component level, through component adaptation techniques, but they also must be tackled at an architectural level of abstraction. In this paper we propose an

  7. Mismatch-shaping switching for two-capacitor DAC

    DEFF Research Database (Denmark)

    Steensgaard-Madsen, Jesper; Moon, U.; Temes, G.C.

    1998-01-01

    A mismatch-shaping scheme is proposed for a two-capacitor digital-to-analogue converter (DAC). It uses a delta-sigma loop for finding the optimal switching sequence for each input word. Simulations indicate that the scheme can be used for the realisation of DACs with 16 bit linearity and SNR perf...

  8. Understanding the Mismatch Between Coaches' and Players' Perceptions of Exertion

    NARCIS (Netherlands)

    Brink, Michel S; Kersten, Anna W; Frencken, Wouter G

    2016-01-01

    A mismatch between the intended training exertion by the coach and the perceived exertion by players is well established in sports. However, it is unknown if coaches are able to accurately observe exertion of individual players during training. Furthermore, the discrepancy in coaches' and players' p

  9. Investigating Interaural Frequency-Place Mismatches via Bimodal Vowel Integration

    DEFF Research Database (Denmark)

    Guérit, François; Santurette, Sébastien; Chalupper, Josef;

    2014-01-01

    For patients having residual hearing in one ear and a cochlear implant (CI) in the opposite ear, interaural place-pitch mismatches might be partly responsible for the large variability in individual benefit. Behavioral pitch-matching between the two ears has been suggested as a way to individuali...

  10. BEPS Action 2: Neutralizing the Effects on Hybrid Mismatch Arrangements

    NARCIS (Netherlands)

    de Boer, R.; Marres, O.

    2015-01-01

    Curbing tax arbitrage is one of the main priorities of the Organization for Economic Cooperation and Development (OECD) (endorsed by the G20 and the G8) ever since the public debate on base erosion fully erupted. Neutralizing the effect of hybrid mismatch arrangements has become Action No. 2 of the

  11. Mismatch of Vocational Graduates: What Penalty on French Labour Market?

    Science.gov (United States)

    Beduwe, Catherine; Giret, Jean-Francois

    2011-01-01

    This study explores individual effects of educational mismatch on wages, job satisfaction and on-the-job-search on French labour market. We distinguish between horizontal matches (job matches with field of studies) and vertical matches (job matches the level of qualification) on the one hand and skills matches (worker's assessment) on the other…

  12. Mismatched feature detection with finer granularity for emotional speaker recognition

    Institute of Scientific and Technical Information of China (English)

    Li CHEN; Ying-chun YANG; Zhao-hui WU

    2014-01-01

    The shapes of speakers’ vocal organs change under their different emotional states, which leads to the deviation of the emotional acoustic space of short-time features from the neutral acoustic space and thereby the degradation of the speaker recognition performance. Features deviating greatly from the neutral acoustic space are considered as mismatched features, and they negatively affect speaker recognition systems. Emotion variation produces different feature deformations for different phonemes, so it is reasonable to build a fi ner model to detect mismatched features under each phoneme. However, given the difficulty of phoneme recognition, three sorts of acoustic class recognition- phoneme classes, Gaussian mixture model (GMM) tokenizer, and probabilistic GMM tokenizer- are proposed to replace phoneme recognition. We propose feature pruning and feature regulation methods to process the mismatched features to improve speaker recognition performance. As for the feature regulation method, a strategy of maximizing the between-class distance and minimizing the within-class distance is adopted to train the transformation matrix to regulate the mismatched features. Experiments conducted on the Mandarin affective speech corpus (MASC) show that our feature pruning and feature regulation methods increase the identifi cation rate (IR) by 3.64% and 6.77%, compared with the baseline GMM-UBM (universal background model) algorithm. Also, corresponding IR increases of 2.09% and 3.32% can be obtained with our methods when applied to the state-of-the-art algorithm i-vector.

  13. SKILLS MISMATCH OF THE YOUNG PEOPLE AT THE EUROPEAN LEVEL

    Directory of Open Access Journals (Sweden)

    Hatos Roxana

    2015-07-01

    Full Text Available Transition from school to work is a main issue with many fields of study. Studies on transition from school to work, have highlight the importance of two categories of factors at the level of the individual formal proceedings which may affect how easy it is to graduate to integrate into the labor market: 1 so far as the educational systems are transmitting specific competences as compared with those general and 2 so far as there are direct links between employers and the education system. In this way, are reduced the costs of selection and allocation for employers. A poor articulation between educational institutions and the labor market produce a high level of unmatched competences of assimilated by formal education and competencies required of the labor market (skill mismatch (Parodi et al., 2012. The surveys with European employers reflect particular difficulties that they are experiencing in employment vacancies. Investigation on the European companies in the spring of 2013 found that 40% of the firms in the EU have difficulty in finding employees with suitable qualification (CEDEFOP-European Center for the Development of the Vocational Training, 2014. Skills mismatch is a generic term that refers to various types of imbalances between skills and competences offered and those required in the labor market. Concept has become one intensely discussed and submitted to measurement in international research on the background concerns the under-utilization human resource. Numerous opinion polls with employers come to the same unexpected conclusion - that despite high unemployment many posts can't find occupants satisfactorily prepared and identify the causes: most of them criticized the lack of skills of the candidates or the absence of skills specific to the workplace. Based on the latest studies on international databases have built a set of questions that, through secondary analysis, we tried to find answers. Questions that we try to give answer

  14. Design of a rapidly cooled cryogenic mirror

    Science.gov (United States)

    Plummer, Ron; Hsu, Ike

    1993-01-01

    The paper discusses the design, analysis, and testing of a rapidly cooled beryllium cryogenic mirror, which is the primary mirror in the four-element optical system for the Long Wavelength Infrared Advanced Technology Seeker. The mirror is shown to meet the requirement of five minutes for cooling to cryogenic operating temperature; it also maintains its optical figure and vacuum integrity and meets the nuclear specification. Results of a detailed thermal analysis on the mirror showed that, using nitrogen gas at 80 K as coolant, the front face of the mirror can be cooled from an initial temperature of 300 K to less than 90 K within five minutes. In a vacuum chamber, using liquid nitrogen as coolant, the mirror can be cooled to 80 K within 1.5 min. The mirror is well thermally insulated, so that it can be maintained at less than its operating temperature for a long time without active cooling.

  15. The effect of cooling water on magnet vibrations

    CERN Document Server

    Redaelli, S; Coosemans, Williame; Schnell, Wolfgang

    2002-01-01

    The quadrupole magnets in the CLIC Test Facility II (CTF2) incorporate a water cooling circuit. In the frame-work of the CLIC stability study, the mechanical vibrations of the magnets were measured for different flows of cool-ing water. We present the results and compare them with simple theoretical estimates. It is shown that the vibra-tion requirements of the Compact LInear Collider (CLIC) quadrupoles with cooling water can basically be met.

  16. Inductive cooling in quantum magnetomechanics

    Science.gov (United States)

    Romero-Sanchez, Erick; Twamley, Jason; Bowen, Warwick P.; Vanner, Michael R.

    Coupling to light or microwave fields allows quantum control of the motion of a mechanical oscillator, and offers prospects for precision sensing, quantum information systems, and tests of fundamental physics. In cavity electromechanics ground state cooling has been achieved using resolved sideband cooling. Here we present an alternative approach based on a magnetomechanical system that inductively couples an LC resonator to a mechanical oscillator. The experimental setup consists of a micro cantilever with a pyramidal magnetic tip attached at the end of the beam. The sharp end of the magnetic tip is positioned close to the planar microfabricated inductor of the LC resonator. The displacement in the position of the end of the cantilever generates a change in flux through the coil inducing an electromotive force in the circuit. The current in the LC resonator generates a magnetic field, and then a force between the tip and the coil. When they are strongly coupled and the mechanical resonance frequency ωm exceeds the electrical decay rate of the resonator γe, resolved sideband cooling can be used to cool the mechanics. We present estimations for the coupling rates and the experimental parameters required for these experiments. E. Romero acknowledges to CONACyT.

  17. Elastocaloric cooling: Stretch to actively cool

    Science.gov (United States)

    Ossmer, Hinnerk; Kohl, Manfred

    2016-10-01

    The elastocaloric effect can be exploited in solid-state cooling technologies as an alternative to conventional vapour compression. Now, an elastocaloric device based on the concept of active regeneration achieves a temperature lift of 15.3 K and efficiencies competitive with other caloric-based approaches.

  18. Measure Guideline: Ventilation Cooling

    Energy Technology Data Exchange (ETDEWEB)

    Springer, D.; Dakin, B.; German, A.

    2012-04-01

    The purpose of this measure guideline on ventilation cooling is to provide information on a cost-effective solution for reducing cooling system energy and demand in homes located in hot-dry and cold-dry climates. This guideline provides a prescriptive approach that outlines qualification criteria, selection considerations, and design and installation procedures.

  19. The final cool down

    CERN Multimedia

    Thursday 29th May, the cool-down of the final sector (sector 4-5) of LHC has begun, one week after the start of the cool-down of sector 1-2. It will take five weeks for the sectors to be cooled from room temperature to 5 K and a further two weeks to complete the cool down to 1.9 K and the commissioning of cryogenic instrumentation, as well as to fine tune the cryogenic plants and the cooling loops of cryostats.Nearly a year and half has passed since sector 7-8 was cooled for the first time in January 2007. For Laurent Tavian, AT/CRG Group Leader, reaching the final phase of the cool down is an important milestone, confirming the basic design of the cryogenic system and the ability to operate complete sectors. “All the sectors have to operate at the same time otherwise we cannot inject the beam into the machine. The stability and reliability of the cryogenic system and its utilities are now very important. That will be the new challenge for the coming months,” he explains. The status of the cool down of ...

  20. Solar absorption cooling

    NARCIS (Netherlands)

    Kim, D.-S.

    2007-01-01

    As the world concerns more and more on global climate changes and depleting energy resources, solar cooling technology receives increasing interests from the public as an environment-friendly and sustainable alternative. However, making a competitive solar cooling machine for the market still

  1. Passive evaporative cooling

    NARCIS (Netherlands)

    Tzoulis, A.

    2011-01-01

    This "designers' manual" is made during the TIDO-course AR0531 Smart & Bioclimatic Design. Passive techniques for cooling are a great way to cope with the energy problem of the present day. This manual introduces passive cooling by evaporation. These methods have been used for many years in traditi

  2. Data center cooling method

    Energy Technology Data Exchange (ETDEWEB)

    Chainer, Timothy J.; Dang, Hien P.; Parida, Pritish R.; Schultz, Mark D.; Sharma, Arun

    2015-08-11

    A method aspect for removing heat from a data center may use liquid coolant cooled without vapor compression refrigeration on a liquid cooled information technology equipment rack. The method may also include regulating liquid coolant flow to the data center through a range of liquid coolant flow values with a controller-apparatus based upon information technology equipment temperature threshold of the data center.

  3. Liquid Cooled Garments

    Science.gov (United States)

    1979-01-01

    Astronauts working on the surface of the moon had to wear liquid-cooled garments under their space suits as protection from lunar temperatures which sometimes reach 250 degrees Fahrenheit. In community service projects conducted by NASA's Ames Research Center, the technology developed for astronaut needs has been adapted to portable cooling systems which will permit two youngsters to lead more normal lives.

  4. Solar absorption cooling

    NARCIS (Netherlands)

    Kim, D.-S.

    2007-01-01

    As the world concerns more and more on global climate changes and depleting energy resources, solar cooling technology receives increasing interests from the public as an environment-friendly and sustainable alternative. However, making a competitive solar cooling machine for the market still remain

  5. Coherent electron cooling

    Energy Technology Data Exchange (ETDEWEB)

    Litvinenko,V.

    2009-05-04

    Cooling intense high-energy hadron beams remains a major challenge in modern accelerator physics. Synchrotron radiation is still too feeble, while the efficiency of two other cooling methods, stochastic and electron, falls rapidly either at high bunch intensities (i.e. stochastic of protons) or at high energies (e-cooling). In this talk a specific scheme of a unique cooling technique, Coherent Electron Cooling, will be discussed. The idea of coherent electron cooling using electron beam instabilities was suggested by Derbenev in the early 1980s, but the scheme presented in this talk, with cooling times under an hour for 7 TeV protons in the LHC, would be possible only with present-day accelerator technology. This talk will discuss the principles and the main limitations of the Coherent Electron Cooling process. The talk will describe the main system components, based on a high-gain free electron laser driven by an energy recovery linac, and will present some numerical examples for ions and protons in RHIC and the LHC and for electron-hadron options for these colliders. BNL plans a demonstration of the idea in the near future.

  6. Rapid identification of a major diffusion/perfusion mismatch in distal internal carotid artery or middle cerebral artery ischemic stroke

    Directory of Open Access Journals (Sweden)

    Hakimelahi Reza

    2012-11-01

    Full Text Available Abstract Background We tested the hypothesis that in patients with occlusion of the terminal internal carotid artery and/or the proximal middle cerebral artery, a diffusion abnormality of 70 ml or less is accompanied by a diffusion/perfusion mismatch of at least 100%. Methods Sixty-eight consecutive patients with terminal ICA and/or proximal MCA occlusions and who underwent diffusion/perfusion MRI within 24 hours of stroke onset were retrospectively identified. DWI and mean transit time (MTT volumes were measured. Prospectively, 48 consecutive patients were identified with the same inclusion criteria. DWI and time to peak (TTP lesion volumes were measured. A large mismatch volume was defined as an MTT or TTP abnormality at least twice the DWI lesion volume. Results In the retrospective study, 49 of 68 patients had a DWI lesion volume ≤ 70 ml (mean 20.2 ml; SEM 2.9 ml. A DWI/MTT mismatch of > 100% was observed in all 49 patients (P  100% was present in all 35 (P  Conclusions Acute stroke patients with major anterior circulation artery occlusion are exceedingly likely to have a major diffusion/perfusion mismatch if the diffusion lesion volume is 70 ml or less. This suggests that physiology-based patient assessments may be made using only vessel imaging and diffusion MRI as a simple alternative to perfusion imaging.

  7. Modeling gasodynamic vortex cooling

    Science.gov (United States)

    Allahverdyan, A. E.; Fauve, S.

    2017-08-01

    We aim at studying gasodynamic vortex cooling in an analytically solvable, thermodynamically consistent model that can explain limitations on the cooling efficiency. To this end, we study an angular plus radial flow between two (coaxial) rotating permeable cylinders. Full account is taken of compressibility, viscosity, and heat conductivity. For a weak inward radial flow the model qualitatively describes the vortex cooling effect, in terms of both temperature and the decrease of the stagnation enthalpy, seen in short uniflow vortex (Ranque) tubes. The cooling does not result from external work and its efficiency is defined as the ratio of the lowest temperature reached adiabatically (for the given pressure gradient) to the lowest temperature actually reached. We show that for the vortex cooling the efficiency is strictly smaller than 1, but in another configuration with an outward radial flow, we find that the efficiency can be larger than 1. This is related to both the geometry and the finite heat conductivity.

  8. Hydronic rooftop cooling systems

    Science.gov (United States)

    Bourne, Richard C.; Lee, Brian Eric; Berman, Mark J.

    2008-01-29

    A roof top cooling unit has an evaporative cooling section that includes at least one evaporative module that pre-cools ventilation air and water; a condenser; a water reservoir and pump that captures and re-circulates water within the evaporative modules; a fan that exhausts air from the building and the evaporative modules and systems that refill and drain the water reservoir. The cooling unit also has a refrigerant section that includes a compressor, an expansion device, evaporator and condenser heat exchangers, and connecting refrigerant piping. Supply air components include a blower, an air filter, a cooling and/or heating coil to condition air for supply to the building, and optional dampers that, in designs that supply less than 100% outdoor air to the building, control the mixture of return and ventilation air.

  9. INITIAL COOLING EXPERIMENT (ICE)

    CERN Multimedia

    1979-01-01

    ICE was built in 1977, using the modified bending magnets of the g-2 muon storage ring (see 7405430). Its purpose was to verify the validity of stochastic and electron cooling for the antiproton project. Stochastic cooling proved a resounding success early in 1978 and the antiproton project could go ahead, now entirely based on stochastic cooling. Electron cooling was experimented with in 1979. The 26 kV equipment is housed in the cage to the left of the picture, adjacent to the "e-cooler" located in a straight section of the ring. With some modifications, the cooler was later transplanted into LEAR (Low Energy Antiproton Ring) and then, with further modifications, into the AD (Antiproton Decelerator), where it cools antiprotons to this day (2006). See also: 7711282, 7802099, 7809081.

  10. Thermal-Hydraulic System Study of the Helium Cooled Pebble Bed (HCPB) Test Blanket Module (TBM) for ITER Using System Code RELAP5

    Science.gov (United States)

    Jin, Xuezhou; R, Meyder

    2005-04-01

    The HCPB concept has been a European DEMO reference concept for nearly one decade. Detailed thermal-hydraulic study on the control behavior of the whole system is one of the important parts of this development. The thermal-hydraulic effect of the TBM-combined cooling circuit during a cyclic operation in ITER has been studied using the system code RELAP5. The RELAP5 is based on an one-dimensional, transient two-fluid model for the flow of a two-phase steam-water mixture that can contain noncondensable components like Helium. The RELAP5-models are modified to take the cyclic operation of the circulator, heat exchanger, bypass, valves etc in to account. A sequence of operational phases is investigated, starting from the cold state through the heating phase that brings the system to a stand-by condition, followed by typical power cycles applied in ITER. The results show that the implemented control mechanisms keep the inlet temperature to the TBM and the total mass flow rate at the required values through all phases.

  11. Thermal-Hydraulic System Study of the Helium Cooled Pebble Bed (HCPB) Test Blanket Module (TBM) for ITER Using System Code RELAP5

    Institute of Scientific and Technical Information of China (English)

    Jin Xuezhou; R. Meyder

    2005-01-01

    The HCPB concept has been a European DEMO reference concept for nearly one decade. Detailed thermal-hydraulic study on the control behavior of the whole system is one of the important parts of this development. The thermal-hydraulic effect of the TBM-combined cooling circuit during a cyclic operation in ITER has been studied using the system code RELAP5. The RELAP5 is based on an one-dimensional, transient two-fluid model for the flow of a two-phase steam-water mixture that can contain noncondensable components like Helium. The RELAP5-models are modified to take the cyclic operation of the circulator, heat exchanger, bypass, valves etc in to account. A sequence of operational phases is investigated, starting from the cold state through the heating phase that brings the system to a stand-by condition, followed by typical power cycles applied in ITER. The results show that the implemented control mechanisms keep the inlet temperature to the TBM and the total mass flow rate at the required values through all phases.

  12. The hippocampus is sensitive to the mismatch in novelty between items and their contexts.

    Science.gov (United States)

    Thakral, Preston P; Yu, Sarah S; Rugg, Michael D

    2015-03-30

    In previous functional magnetic resonance imaging (fMRI) studies of continuous recognition memory it was reported that new items elicit greater hippocampal activity than old (repeated) items (hippocampal 'novelty' effects). Rather than reflecting recency differences between new and old items, hippocampal novelty effects may instead reflect the novelty of the association between test items and the experimental context, or a mismatch in the novelty of the test item and the context. The present continuous recognition study assessed these possibilities by manipulating item-context associations on a trial-by-trial basis. Each trial comprised the presentation of an object-word (context-item) pair. Repeated items were paired either with the same context as on their first presentation, a different but previously presented context, or a new context. The task was to judge whether each item was old or new, regardless of the study status of the associated context. We found no evidence that hippocampal novelty effects reflected either item and context recency, or the novelty of the item-context association. Rather, enhanced hippocampal activity was elicited when the novelty of the item and its context mismatched. These findings support the possibility that hippocampal novelty effects reflect, at least in part, the disjunction in novelty between test items and their contexts.

  13. Evaporative Cooling of Antiprotons to Cryogenic Temperatures

    Science.gov (United States)

    Andresen, G. B.; Ashkezari, M. D.; Baquero-Ruiz, M.; Bertsche, W.; Bowe, P. D.; Butler, E.; Cesar, C. L.; Chapman, S.; Charlton, M.; Fajans, J.; Friesen, T.; Fujiwara, M. C.; Gill, D. R.; Hangst, J. S.; Hardy, W. N.; Hayano, R. S.; Hayden, M. E.; Humphries, A.; Hydomako, R.; Jonsell, S.; Kurchaninov, L.; Lambo, R.; Madsen, N.; Menary, S.; Nolan, P.; Olchanski, K.; Olin, A.; Povilus, A.; Pusa, P.; Robicheaux, F.; Sarid, E.; Silveira, D. M.; So, C.; Storey, J. W.; Thompson, R. I.; van der Werf, D. P.; Wilding, D.; Wurtele, J. S.; Yamazaki, Y.

    2010-07-01

    We report the application of evaporative cooling to clouds of trapped antiprotons, resulting in plasmas with measured temperature as low as 9 K. We have modeled the evaporation process for charged particles using appropriate rate equations. Good agreement between experiment and theory is observed, permitting prediction of cooling efficiency in future experiments. The technique opens up new possibilities for cooling of trapped ions and is of particular interest in antiproton physics, where a precise CPT test on trapped antihydrogen is a long-standing goal.

  14. Evaporative Cooling of Antiprotons to Cryogenic Temperatures

    CERN Document Server

    Andresen, G B; Baquero-Ruiz, M; Bertsche, W; Bowe, P D; Butler, E; Cesar, C L; Chapman, S; Charlton, M; Fajans, J; Friesen, T; Fujiwara, M C; Gill, D R; Hangst, J S; Hardy, W N; Hayano, R S; Hayden, M E; Humphries, A; Hydomako, R; Jonsell, S; Kurchaninov, L; Lambo, R; Madsen, N; Menary, S; Nolan, P; Olchanski, K; Olin, A; Povilus, A; Pusa, P; Robicheaux, F; Sarid, E; Silveira, D M; So, C; Storey, J W; Thompson, R I; van der Werf, D P; Wilding, D; Wurtele, J S; Yamazaki, Y

    2010-01-01

    We report the application of evaporative cooling to clouds of trapped antiprotons, resulting in plasmas with measured temperature as low as 9~K. We have modeled the evaporation process for charged particles using appropriate rate equations. Good agreement between experiment and theory is observed, permitting prediction of cooling efficiency in future experiments. The technique opens up new possibilities for cooling of trapped ions and is of particular interest in antiproton physics, where a precise CPT test on trapped antihydrogen is a long-standing goal.

  15. Mismatch Responses to Lexical Tone, Initial Consonant, and Vowel in Mandarin-Speaking Preschoolers

    Science.gov (United States)

    Lee, Chia-Ying; Yen, Huei-ling; Yeh, Pei-wen; Lin, Wan-Hsuan; Cheng, Ying-Ying; Tzeng, Yu-Lin; Wu, Hsin-Chi

    2012-01-01

    The present study investigates how age, phonological saliency, and deviance size affect the presence of mismatch negativity (MMN) and positive mismatch response (P-MMR). This work measured the auditory mismatch responses to Mandarin lexical tones, initial consonants, and vowels in 4- to 6-year-old preschoolers using the multiple-deviant oddball…

  16. 风冷冷热水机组测试系统的优化改进%Optimization of the Test System for Air-Cooled and Cold/Hot Water Unit

    Institute of Scientific and Technical Information of China (English)

    田杰; 余晓明; 李萌; 忍继斌; 张强

    2016-01-01

    在原有实验系统的基础上,对风冷冷热水机组进行优化设计,并针对常规系统中余热存在浪费的现象,以及制冷机和空气加热器同时工作造成极大能源浪费的问题进行了优化改进。为了节省风冷冷热水机组性能测试试验室的耗电量,提出了一种新型试验室节能改进设计方案,即在工况机组上增设热回收器回收利用高温高压气体,以期达到节能目的。%The air-cooled and cold/hot water unit is optimized with the original experiment system. Both the waste heat in the general system and the serious energy waste while refrigerators and air heaters operate together, are improved. In order to save the power consumption of performance testing laboratory for air -cooled and cold/hot water unit, this paper presents a new type of energy saving improvement solution for laboratory design installing the heat reclaiming device on the operated unit to recovery air of high temperature and high pressure, and achieve the goal of energy saving.

  17. Measuring the coolness of interactive products: the COOL questionnaire

    DEFF Research Database (Denmark)

    Bruun, Anders; Raptis, Dimitrios; Kjeldskov, Jesper;

    2016-01-01

    is the COOL questionnaire. We based the creation of the questionnaire on literature suggesting that perceived coolness is decomposed to outer cool (the style of a product) and inner cool (the personality characteristics assigned to it). In this paper, we focused on inner cool, and we identified 11 inner cool......, rebelliousness and usability. These factors and their underlying 16 question items comprise the COOL questionnaire. The whole process of creating the questionnaire is presented in detail in this paper and we conclude by discussing our work against related work on coolness and HCI....

  18. Cool WISPs for stellar cooling excesses

    Energy Technology Data Exchange (ETDEWEB)

    Giannotti, Maurizio [Barry Univ., Miami Shores, FL (United States). Physical Sciences; Irastorza, Igor [Zaragoza Univ. (Spain). Dept. de Fisica Teorica; Redondo, Javier [Zaragoza Univ. (Spain). Dept. de Fisica Teorica; Max-Planck-Institut fuer Physik, Muenchen (Germany); Ringwald, Andreas [DESY Hamburg (Germany). Theory Group

    2015-12-15

    Several stellar systems (white dwarfs, red giants, horizontal branch stars and possibly the neutron star in the supernova remnant Cassiopeia A) show a preference for a mild non-standard cooling mechanism when compared with theoretical models. This exotic cooling could be provided by Weakly Interacting Slim Particles (WISPs), produced in the hot cores and abandoning the star unimpeded, contributing directly to the energy loss. Taken individually, these excesses do not show a strong statistical weight. However, if one mechanism could consistently explain several of them, the hint could be significant. We analyze the hints in terms of neutrino anomalous magnetic moments, minicharged particles, hidden photons and axion-like particles (ALPs). Among them, the ALP represents the best solution. Interestingly, the hinted ALP parameter space is accessible to the next generation proposed ALP searches, such as ALPS II and IAXO.

  19. Cool WISPs for stellar cooling excesses

    CERN Document Server

    Giannotti, Maurizio; Redondo, Javier; Ringwald, Andreas

    2015-01-01

    Several stellar systems (white dwarfs, red giants, horizontal branch stars and possibly the neutron star in the supernova remnant Cassiopeia A) show a preference for a mild non-standard cooling mechanism when compared with theoretical models. This exotic cooling could be provided by Weakly Interacting Slim Particles (WISPs), produced in the hot cores and abandoning the star unimpeded, contributing directly to the energy loss. Taken individually, these excesses do not show a strong statistical weight. However, if one mechanism could consistently explain several of them, the hint could be significant. We analyze the hints in terms of neutrino anomalous magnetic moments, minicharged particles, hidden photons and axion-like particles (ALPs). Among them, the ALP represents the best solution. Interestingly, the hinted ALP parameter space is accessible to the next generation proposed ALP searches, such as ALPS II and IAXO.

  20. Mismatches in Phenology of Birds and Their Food Due to Climate Change: Big Data, Analytical Challenges, and Scale Sensitivity

    Science.gov (United States)

    Mayor, S.; Andrew, M. E.; Elmendorf, S.; Guralnick, R. P.; Minor, E. S.; Schneider, D.; Tersigni, V.; Thibault, K. M.; Tingley, M. W.; Withey, J. C.

    2013-12-01

    We explored analytical issues that come with challenging ecological concepts against large data sets. As an example, we examined the expected mismatch between the phenology (annual timing) of endothermic migratory birds with the phenology of primarily ectothermic (degree-day dependent) food resources. We hypothesized that bird phenology, which is often tightly hormonally tied to day length cues would be increasing out of phase the phenology of their food resources, due to increases in both mean and variability of spring temperatures. Specifically, we tested whether bird populations have been able to match their migration times to the timing of spring 'greenup', when food resources become plentiful. If not, we also test if suboptimal migration timing resulted in negative fitness consequences for individual bird species? We expected (1) a mismatch between optimal migration time and observed migration time; (2) greater variation in mean timing of ectothermic prey resources than migratory arrival of endothermic birds; (3) higher per capita survival and reproduction of species with the smallest optimal/observed migration timing mismatch. We tested these expectations with rich datasets extensive in both time and space. We brought together nearly a decade of migratory arrival records for over 100 bird species across the continental U.S. (eBird) with remotely sensed (MODIS) time of spring greenup, which is concurrent with insect abundance, and survival and reproduction estimates for each bird species (MAPS). In testing these questions with large data sets, we encountered several challenges. First, selecting the spatial scale(s) of analyses involve a priori estimation of scale(s) at which birds select food resources, and mismatches depend on analytical scale. To assess a mismatch in phenology (between birds and food), we attempted to minimize a mismatch in scales (between analyses and phenomena). Second, forming causal linkages between variables relied on previous

  1. 10 MW高温气冷堆反应堆压力容器的出厂水压试验%Hydraulic Pressure Test of Pressure Vessel of 10 MW High Temperature Gas-cooled Reactor

    Institute of Scientific and Technical Information of China (English)

    刘俊杰; 张征明; 何树延; 王金海

    2001-01-01

    The hydraulic pressure test of 10MW Hight Temperature Gas-cooled Reactorc(HTR-10) pressure vessel was successfully performed according to the requirement of the section NB-6200, ASME Ⅲ code. The test requirement, the test results and the test evaluations are described in detail. The test tension was effectively and rationally done through an hydraulic tensionor, which was developed at institue of nuclear energy technology of Tsinghua University. The strain and deformation of the HTR-10 pressure vessel were also measured.%根据ASME规范第Ⅲ卷NB-6200节的规定,对10MW高温气冷堆压力容器的水压试验要求、试验过程,试验结果及评价进行了叙述。用清华大学核能技术设计研究院研制的液压张拉机对主螺栓实施了合理及有效的张拉,对压力容器进行了应变和变形测量,取得了反应堆压力容器水压试验的圆满成功。

  2. Noise and mismatch optimization for capacitive MEMS readout

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Chong; Wu Qisong; Yin Tao; Yang Haigang, E-mail: yanghg@mail.ie.ac.c [Institute of Electronics, Chinese Academy of Sciences, Beijing 100190 (China)

    2009-11-15

    This paper presents a high precision CMOS readout circuit for a capacitive MEMS gyroscope. A continuous time topology is employed as well as the chopper noise cancelling technique. A detailed analysis of the noise and mismatch of the capacitive readout circuit is given. The analysis and measurement results have shown that thermal noise dominates in the proposed circuit, and several approaches should be used for both noise and mismatch optimization. The circuit chip operates under a single 5 V supply, and has a measured capacitance resolution of 0.2 aF/sq rootHz. With such a readout circuit, the gyroscope can accurately measure the angular rate with a sensitivity of 15.3 mV/{sup 0}/s. (semiconductor integrated circuits)

  3. Noise and mismatch optimization for capacitive MEMS readout

    Institute of Scientific and Technical Information of China (English)

    Zhang Chong; Wu Qisong; Yin Tao; Yang Haigang

    2009-01-01

    This paper presents a high precision CMOS readout circuit for a capacitive MEMS gyroscope. A continuous time topology is employed as well as the chopper noise cancelling technique. A detailed analysis of the noise and mismatch of the capacitive readout circuit is given. The analysis and measurement results have shown that thermal noise dominates in the proposed circuit, and several approaches should be used for both noise and mismatch optimization. The circuit chip operates under a single 5 V supply, and has a measured capacitance resolution of 0.2 aF/√Hz. With such a readout circuit, the gyroscope can accurately measure the angular rate with a sensitivity of 15.3 mV/°/s.

  4. Fuzzy Backstepping Sliding Mode Control for Mismatched Uncertain System

    Directory of Open Access Journals (Sweden)

    H. Q. Hou

    2014-06-01

    Full Text Available Sliding mode controllers have succeeded in many control problems that the conventional control theories have difficulties to deal with; however it is practically impossible to achieve high-speed switching control. Therefore, in this paper an adaptive fuzzy backstepping sliding mode control scheme is derived for mismatched uncertain systems. Firstly fuzzy sliding mode controller is designed using backstepping method based on the Lyapunov function approach, which is capable of handling mismatched problem. Then fuzzy sliding mode controller is designed using T-S fuzzy model method, it can improve the performance of the control systems and their robustness. Finally this method of control is applied to nonlinear system as a case study; simulation results are also provided the performance of the proposed controller.

  5. Effect of resonant-frequency mismatch on attractors.

    Science.gov (United States)

    Wang, Xingang; Lai, Ying-Cheng; Lai, Choy Heng

    2006-06-01

    Resonant perturbations are effective for harnessing nonlinear oscillators for various applications such as controlling chaos and inducing chaos. Of physical interest is the effect of small frequency mismatch on the attractors of the underlying dynamical systems. By utilizing a prototype of nonlinear oscillators, the periodically forced Duffing oscillator and its variant, we find a phenomenon: resonant-frequency mismatch can result in attractors that are nonchaotic but are apparently strange in the sense that they possess a negative Lyapunov exponent but its information dimension measured using finite numerics assumes a fractional value. We call such attractors pseudo-strange. The transition to pesudo-strange attractors as a system parameter changes can be understood analytically by regarding the system as nonstationary and using the Melnikov function. Our results imply that pseudo-strange attractors are common in nonstationary dynamical systems.

  6. Mismatch between classroom furniture and anthropometric measures in Chilean schools.

    Science.gov (United States)

    Castellucci, H I; Arezes, P M; Viviani, C A

    2010-07-01

    Children spend about five hours per day sitting down while doing their school work. Considering this as well as the potential inadequate use of school furniture, it is likely that some anatomical-functional changes and problems in the learning process may occur. The aim of this study was to compare furniture sizes within three different schools with the anthropometric characteristics of Chilean students in the Valparaíso region, in order to evaluate the potential mismatch between them. The sample consisted of 195 volunteer students (94 male, 101 female) of the 8th grade, ranging from 12.5 to 14.5 years of age from 3 different schools. Regarding the methodology, 6 anthropometric measures (Stature, Popliteal height, Buttock-popliteal length, Elbow height while sitting, Hip width, Thigh thickness and Subscapular height) were gathered, as well as 8 dimensions from the school furniture. For the evaluation of classroom furniture a match criterion equation was defined. After considering the existing classroom furniture dimensions in each match criterion equation, the anthropometric characteristics of the considered population were compared in order to determine the mismatch between them. Results indicated that seat height, which should be considered as the starting point for the design of classroom furniture, was appropriate for students' popliteal height in only 14% of the 2 out of the 3 schools, and 28% in the third. Seat to desk height was too high and mismatched 99% of the students in one school and 100% in the others. Therefore, it was possible to conclude that the classroom's furniture was inadequate in almost all the analyzed cases and subjects. It is possible that the high mismatch percentage found between furniture and students' anthropometry can be associated to the fact that the acquisition and selection of the furniture was made without any ergonomic concern or criteria.

  7. Match mismatch processes underlie human hippocampal responses to associative novelty.

    Science.gov (United States)

    Kumaran, Dharshan; Maguire, Eleanor A

    2007-08-08

    The hippocampus has long been proposed to play a critical role in novelty detection through its ability to act as a comparator between past and present experience. A recent study provided evidence for this hypothesis by characterizing hippocampal responses to sequence novelty, a type of associative novelty where familiar items appear in a new temporal order. Here, we ask whether a hippocampal match-mismatch (i.e., comparator) mechanism operates selectively to identify the violation of predictions within the temporal domain or instead also underlies the processing of associative novelty in other domains (e.g., spatial). We used functional magnetic resonance imaging and a repetition paradigm in which subjects viewed sequences of objects presented in distinct locations on the screen and performed an incidental target detection task. The left hippocampus exhibited a pattern of activity consistent with that of an associative match-mismatch detector, with novelty signals generated only in conditions where one contextual component was novel and the other repeated. In contrast, right hippocampal activation signaled the presence of objects in familiar locations. Our results suggest that hippocampal match-mismatch computations constitute a general mechanism underpinning the processing of associative novelty. These findings support a model in which hippocampal mismatch signals rely critically on the recall of previous experience, a process that only occurs when novel sensory inputs overlap significantly with stored representations. More generally, the current study also offers insights into how the hippocampus automatically represents the spatiotemporal context of our experiences, a function that may relate to its role in episodic memory.

  8. Phenotypic mismatches reveal escape from arms-race coevolution.

    Science.gov (United States)

    Hanifin, Charles T; Brodie, Edmund D; Brodie, Edmund D

    2008-03-11

    Because coevolution takes place across a broad scale of time and space, it is virtually impossible to understand its dynamics and trajectories by studying a single pair of interacting populations at one time. Comparing populations across a range of an interaction, especially for long-lived species, can provide insight into these features of coevolution by sampling across a diverse set of conditions and histories. We used measures of prey traits (tetrodotoxin toxicity in newts) and predator traits (tetrodotoxin resistance of snakes) to assess the degree of phenotypic mismatch across the range of their coevolutionary interaction. Geographic patterns of phenotypic exaggeration were similar in prey and predators, with most phenotypically elevated localities occurring along the central Oregon coast and central California. Contrary to expectations, however, these areas of elevated traits did not coincide with the most intense coevolutionary selection. Measures of functional trait mismatch revealed that over one-third of sampled localities were so mismatched that reciprocal selection could not occur given current trait distributions. Estimates of current locality-specific interaction selection gradients confirmed this interpretation. In every case of mismatch, predators were "ahead" of prey in the arms race; the converse escape of prey was never observed. The emergent pattern suggests a dynamic in which interacting species experience reciprocal selection that drives arms-race escalation of both prey and predator phenotypes at a subset of localities across the interaction. This coadaptation proceeds until the evolution of extreme phenotypes by predators, through genes of large effect, allows snakes to, at least temporarily, escape the arms race.

  9. Phenotypic mismatches reveal escape from arms-race coevolution.

    Directory of Open Access Journals (Sweden)

    Charles T Hanifin

    2008-03-01

    Full Text Available Because coevolution takes place across a broad scale of time and space, it is virtually impossible to understand its dynamics and trajectories by studying a single pair of interacting populations at one time. Comparing populations across a range of an interaction, especially for long-lived species, can provide insight into these features of coevolution by sampling across a diverse set of conditions and histories. We used measures of prey traits (tetrodotoxin toxicity in newts and predator traits (tetrodotoxin resistance of snakes to assess the degree of phenotypic mismatch across the range of their coevolutionary interaction. Geographic patterns of phenotypic exaggeration were similar in prey and predators, with most phenotypically elevated localities occurring along the central Oregon coast and central California. Contrary to expectations, however, these areas of elevated traits did not coincide with the most intense coevolutionary selection. Measures of functional trait mismatch revealed that over one-third of sampled localities were so mismatched that reciprocal selection could not occur given current trait distributions. Estimates of current locality-specific interaction selection gradients confirmed this interpretation. In every case of mismatch, predators were "ahead" of prey in the arms race; the converse escape of prey was never observed. The emergent pattern suggests a dynamic in which interacting species experience reciprocal selection that drives arms-race escalation of both prey and predator phenotypes at a subset of localities across the interaction. This coadaptation proceeds until the evolution of extreme phenotypes by predators, through genes of large effect, allows snakes to, at least temporarily, escape the arms race.

  10. Induced Diffraction in Phase-Mismatched Second-Harmonic Generation

    Institute of Scientific and Technical Information of China (English)

    SU Wen-Hua; QIAN Lie-Jia; FU Xi-Quan; YANG Hua; ZHU He-Yuan

    2007-01-01

    We show analytically that in phase-mismatched second-harmonic generation,an effective diffraction is induced at the second-harmonic (SH) frequency.Numerical simulation results agree with the analytical predictions.Compared to the case of linear propagation,the effect of the overall diffraction at the SH frequency becomes doubled due to the induced diffraction,which causes an interesting result that the SH beam width will be larger than that of the fundamental field.

  11. Energy Detection of Multilevel PAM Signals with Systematic Threshold Mismatch

    Directory of Open Access Journals (Sweden)

    Antti Anttonen

    2009-01-01

    Full Text Available We address a symbol decision problem with spectrally efficient energy detected multilevel pulse amplitude modulated (PAM signals. First, we analytically quantify the relationship between a systematic threshold mismatch and the required increase of the average signal-to-noise ratio to preserve a desired symbol error rate. For the case in which such an increase is not tolerable, we present a novel near-optimal multilevel threshold selection scheme, which is accurate for a wide range of system parameters.

  12. Field testing of behavioral barriers for fish exclusion at cooling-water intake systems, Central Hudson Gas and Electric Company Roseton Generating Station: Final report

    Energy Technology Data Exchange (ETDEWEB)

    Matousek, J.A.; Wells, A.W.; McGroddy, P.M.

    1988-09-01

    A seasonal field testing program was conducted during 1986 and 1987 to evaluate the effectiveness of behavioral barriers at Central Hudson Gas and Electric Corporations's Roseton Generating Station located in the euryhaline section of the Hudson River. This station was selected as representative of power plants with shoreline riverine/estuarine intake systems. Three commercially available devices (air bubble curtain, pneumatic gun, and underwater strobe light) were tested alone and in combination to determine their effectiveness in reducing impingement. The primary testing method incorporated three or four 6-h impingement collections during each test date, each consisting of two randomly assigned 3-h samples: one was an experimental test with a behavioral device in operation, the other a control test with no device operating. The effectiveness of the devices at excluding fish was determined by comparing impingement data from experimental and control periods. Results of the program do not establish that the deployment of underwater strobe lights, pneumatic guns, an air bubble curtain, or various combinations of the three devices will effectively lower fish impingement at power plants similar in design and location to the Roseton plant. Deterrent effectiveness was found to be species-specific and related to time of day. 51 refs., 67 figs., 72 tabs.

  13. Memory-based mismatch response to frequency changes in rats.

    Directory of Open Access Journals (Sweden)

    Piia Astikainen

    Full Text Available Any occasional changes in the acoustic environment are of potential importance for survival. In humans, the preattentive detection of such changes generates the mismatch negativity (MMN component of event-related brain potentials. MMN is elicited to rare changes ('deviants' in a series of otherwise regularly repeating stimuli ('standards'. Deviant stimuli are detected on the basis of a neural comparison process between the input from the current stimulus and the sensory memory trace of the standard stimuli. It is, however, unclear to what extent animals show a similar comparison process in response to auditory changes. To resolve this issue, epidural potentials were recorded above the primary auditory cortex of urethane-anesthetized rats. In an oddball condition, tone frequency was used to differentiate deviants interspersed randomly among a standard tone. Mismatch responses were observed at 60-100 ms after stimulus onset for frequency increases of 5% and 12.5% but not for similarly descending deviants. The response diminished when the silent inter-stimulus interval was increased from 375 ms to 600 ms for +5% deviants and from 600 ms to 1000 ms for +12.5% deviants. In comparison to the oddball condition the response also diminished in a control condition in which no repetitive standards were presented (equiprobable condition. These findings suggest that the rat mismatch response is similar to the human MMN and indicate that anesthetized rats provide a valuable model for studies of central auditory processing.

  14. Educational mismatch in the labour market: overqualification and its implications

    Directory of Open Access Journals (Sweden)

    Marija Bečić

    2013-12-01

    Full Text Available Educational mismatch as a labour market disruption has lately attracted the interest of many economic experts and scholars. This interest is spurred by considerable improvements in the educational profile of the population, combined with changes in the demand for highly-qualified workers linked to technological developments. The mismatch can appear if an increase in highly-qualified workforce supply is not accom - panied by an equal growth in the demand. Overqualification is one such type of mismatch: it means that knowledge and skills acquired during formal education remain unused in the workplace. Many economies face this problem that can have negative consequences for individuals, businesses, and the government alike. This paper provides an overview of the basic concepts related to overqualification, focusing on the possible implications of this phenomenon, given that employee dissatisfaction can affect businesses and their productivity, and ultimately, the country as a whole. Systematization of previous research and analysis of the basic concepts related to overqualification can contribute to the literature in economics of education in Croatia and create a foundation for future research

  15. Current status of the Scandiatransplant acceptable mismatch program.

    Science.gov (United States)

    Weinreich, I D; Pedersen, F; Grunnet, N

    2013-04-01

    This article describes the Scandiatransplant Acceptable Mismatch Program (STAMP), which was set into action in 2009. The aim of STAMP is to define human leukocyte antigens (HLA) toward which the potential kidney recipient has not developed antibodies, as "acceptable mismatches" in the Scandiatransplant database. In many cases this may improve the probability for a highly immunized recipient to receive a suitable kidney graft from a deceased donor. Using data extracted from the Scandiatransplant database on the outcomes of the program after the first 3 years, 31/115 recipients included in the program have undergone transplantation. From 2008 to 2011 the mean waiting time for highly immunized patients has decreased from 42 to 37 months. Continuous evaluation and follow-up of the program is essential to improve the procedures and outcomes. Calculation of transplantability based on a given set of acceptable mismatches was added to the program in 2011, based on the historical deceased donor pool providing the possibility of a specific patient to receive a kidney through STAMP. It is still a challenge for the tissue typing laboratories to determine which detected HLA antibodies are clinical relevant. We concluded that STAMP has had the intended effects, however adjustments and improvements is an ongoing process. As an improvment of the program HLA-C was added to the STAMP search algorithm in September 2012.

  16. Semiblind Hyperspectral Unmixing in the Presence of Spectral Library Mismatches

    Science.gov (United States)

    Fu, Xiao; Ma, Wing-Kin; Bioucas-Dias, Jose M.; Chan, Tsung-Han

    2016-09-01

    The dictionary-aided sparse regression (SR) approach has recently emerged as a promising alternative to hyperspectral unmixing (HU) in remote sensing. By using an available spectral library as a dictionary, the SR approach identifies the underlying materials in a given hyperspectral image by selecting a small subset of spectral samples in the dictionary to represent the whole image. A drawback with the current SR developments is that an actual spectral signature in the scene is often assumed to have zero mismatch with its corresponding dictionary sample, and such an assumption is considered too ideal in practice. In this paper, we tackle the spectral signature mismatch problem by proposing a dictionary-adjusted nonconvex sparsity-encouraging regression (DANSER) framework. The main idea is to incorporate dictionary correcting variables in an SR formulation. A simple and low per-iteration complexity algorithm is tailor-designed for practical realization of DANSER. Using the same dictionary correcting idea, we also propose a robust subspace solution for dictionary pruning. Extensive simulations and real-data experiments show that the proposed method is effective in mitigating the undesirable spectral signature mismatch effects.

  17. Halo formation from mismatched beam-beam interactions

    Energy Technology Data Exchange (ETDEWEB)

    Qiang, Ji

    2003-05-23

    In this paper, we report on the halo formation and emittance growth driven by a parametric resonance during mismatched beam-beam collisions. In the regime of the weak-strong beam-beam interaction, if two beams have the same machine tunes, on-axis head-on collisions between a mismatched strong beam and a weak beam will not cause the formation of halo. However, if the two beams collide with an initial offset, the beam-beam force from the mismatched strong beam can cause halo formation and emittance growth in the weak beam. Meanwhile, if two beams have different machine tunes, for opposite charged colliding beams, when the machine tune of the weak beam is smaller than that of strong beam, there is emittance growth in the weak beam. When the machine tune of the weak beam is larger than that of the strong beam, there is little emittance growth. In the regime of strong-strong beam-beam interaction, halo is formed in both beams even when the two beams collide head-on on the axis with equal machine tunes. This puts a strong requirement for a good beam match during the injection to colliders in order to avoid the emittance growth.

  18. Infra-red parametric generation: Phase mismatch condition

    Energy Technology Data Exchange (ETDEWEB)

    Ghosh, S.; Dubey, Swati; Jain, Kamal, E-mail: Jainrupam1987@gmail.com [School of Studies in Physics, Vikram University, Ujjain (M.P.) India-456010 (India)

    2015-07-31

    An analytical investigation is made for the Infrared parametric generation in doped semiconductor plasma under phase mismatch condition. Theoretical formulations are undertaken to determine induced polarization and threshold pump field for the onset of parametric generation in semiconductor plasma medium. The origin of this nonlinear interaction lies in the second order optical susceptibility arising due to the induced nonlinear current density in piezoelectric medium. Numerical estimations are made for n- type InSb at 77 K duly irradiated by a pulsed 10.6µm CO{sub 2} laser. It is very difficult to attain exact phase matching in experimental frame so we have considered a tolerable small phase mismatch in order to attain a new result. Its effect on the Infrared parametric generation in compound semiconductor is examined through induced polarization. Transmitted intensity is determined to have an idea about conversion efficiency of the said process. Phase mismatch tends to raise the required pump field to stimulate the parametric generation. Transmitted intensity is found to decrease with coherence length lc and increase carrier concentration n{sub 0}, which is favorable for improved conversion efficiency.

  19. Infra-red parametric generation: Phase mismatch condition

    Science.gov (United States)

    Ghosh, S.; Dubey, Swati; Jain, Kamal

    2015-07-01

    An analytical investigation is made for the Infrared parametric generation in doped semiconductor plasma under phase mismatch condition. Theoretical formulations are undertaken to determine induced polarization and threshold pump field for the onset of parametric generation in semiconductor plasma medium. The origin of this nonlinear interaction lies in the second order optical susceptibility arising due to the induced nonlinear current density in piezoelectric medium. Numerical estimations are made for n- type InSb at 77 K duly irradiated by a pulsed 10.6µm CO2 laser. It is very difficult to attain exact phase matching in experimental frame so we have considered a tolerable small phase mismatch in order to attain a new result. Its effect on the Infrared parametric generation in compound semiconductor is examined through induced polarization. Transmitted intensity is determined to have an idea about conversion efficiency of the said process. Phase mismatch tends to raise the required pump field to stimulate the parametric generation. Transmitted intensity is found to decrease with coherence length lc and increase carrier concentration n0, which is favorable for improved conversion efficiency.

  20. Cooling Devices in Laser therapy.

    Science.gov (United States)

    Das, Anupam; Sarda, Aarti; De, Abhishek

    2016-01-01

    Cooling devices and methods are now integrated into most laser systems, with a view to protecting the epidermis, reducing pain and erythema and improving the efficacy of laser. On the basis of method employed, it can be divided into contact cooling and non-contact cooling. With respect to timing of irradiation of laser, the nomenclatures include pre-cooling, parallel cooling and post-cooling. The choice of the cooling device is dictated by the laser device, the physician's personal choice with respect to user-friendliness, comfort of the patient, the price and maintenance costs of the device. We hereby briefly review the various techniques of cooling, employed in laser practice.

  1. Brain responses to audiovisual speech mismatch in infants are associated with individual differences in looking behaviour.

    Science.gov (United States)

    Kushnerenko, Elena; Tomalski, Przemyslaw; Ballieux, Haiko; Ribeiro, Helena; Potton, Anita; Axelsson, Emma L; Murphy, Elizabeth; Moore, Derek G

    2013-11-01

    Research on audiovisual speech integration has reported high levels of individual variability, especially among young infants. In the present study we tested the hypothesis that this variability results from individual differences in the maturation of audiovisual speech processing during infancy. A developmental shift in selective attention to audiovisual speech has been demonstrated between 6 and 9 months with an increase in the time spent looking to articulating mouths as compared to eyes (Lewkowicz & Hansen-Tift. (2012) Proc. Natl Acad. Sci. USA, 109, 1431-1436; Tomalski et al. (2012) Eur. J. Dev. Psychol., 1-14). In the present study we tested whether these changes in behavioural maturational level are associated with differences in brain responses to audiovisual speech across this age range. We measured high-density event-related potentials (ERPs) in response to videos of audiovisually matching and mismatched syllables /ba/ and /ga/, and subsequently examined visual scanning of the same stimuli with eye-tracking. There were no clear age-specific changes in ERPs, but the amplitude of audiovisual mismatch response (AVMMR) to the combination of visual /ba/ and auditory /ga/ was strongly negatively associated with looking time to the mouth in the same condition. These results have significant implications for our understanding of individual differences in neural signatures of audiovisual speech processing in infants, suggesting that they are not strictly related to chronological age but instead associated with the maturation of looking behaviour, and develop at individual rates in the second half of the first year of life.

  2. Understanding mismatches in body size, speed and power among adolescent rugby union players.

    Science.gov (United States)

    Krause, Lyndon M; Naughton, Geraldine A; Denny, Greg; Patton, Declan; Hartwig, Tim; Gabbett, Tim J

    2015-05-01

    With adolescent sport increasingly challenged by mismatches in size, new strategies are important to maximize participation. The objectives were to (1) improve the understanding of mismatches in physical size, speed and power in adolescent rugby union players, (2) explore associations between size and performance with demographic, playing-history, and injury profiles, and (3) explore the applicability of existing criteria for age/body mass-based dispensation (playing-down) strategies. Cross-sectional study. Four hundred and eighty-five male community rugby union players were recruited from three Australian states selected to represent community-based U12, U13, U14 and U15 players. Body mass, stature, speed (10, 30, and 40 m sprints) and lower-leg power (relative peak power and relative peak force) were measured. Independent student t-tests, linear regressions and Chi square analyses were undertaken. Mean values in age groups for size, speed and power masked considerable overlap in the ranges within specific age groups of adolescent rugby players. Only a small proportion of players (approximately 5%) shared the highest and lowest tertiles for speed, relative peak power and body mass. Physical size was not related to injury. The mean body mass of current community rugby union players was above the 75th percentile on normative growth-charts. The notion that bigger, faster, and more powerful characteristics occur simultaneously in adolescent rugby players was not supported in the present study. Current practices in body mass-based criteria for playing down an age group lack a sufficient evidence for decision-making. Dispensation solely based on body mass may not address mismatch in junior rugby union. Copyright © 2014 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  3. Variable flowering phenology and pollinator use in a community suggest future phenological mismatch

    Science.gov (United States)

    Petanidou, Theodora; Kallimanis, Athanasios S.; Sgardelis, Stefanos P.; Mazaris, Antonios D.; Pantis, John D.; Waser, Nickolas M.

    2014-08-01

    Recent anthropogenic climate change is strongly associated with average shifts toward earlier seasonal timing of activity (phenology) in temperate-zone species. Shifts in phenology have the potential to alter ecological interactions, to the detriment of one or more interacting species. Recent models predict that detrimental phenological mismatch may increasingly occur between plants and their pollinators. One way to test this prediction is to examine data from ecological communities that experience large annual weather fluctuations. Taking this approach, we analyzed interactions over a four-year period among 132 plant species and 665 pollinating insect species within a Mediterranean community. For each plant species we recorded onset and duration of flowering and number of pollinator species. Flowering onset varied among years, and a year of earlier flowering of a species tended to be a year of fewer species pollinating its flowers. This relationship was attributable principally to early-flowering species, suggesting that shifts toward earlier phenology driven by climate change may reduce pollination services due to phenological mismatch. Earlier flowering onset of a species also was associated with prolonged flowering duration, but it is not certain that this will counterbalance any negative effects of lower pollinator species richness on plant reproductive success. Among plants with different life histories, annuals were more severely affected by flowering-pollinator mismatches than perennials. Specialized plant species (those attracting a smaller number of pollinator species) did not experience disproportionate interannual fluctuations in phenology. Thus they do not appear to be faced with disproportionate fluctuations in pollinator species richness, contrary to the expectation that specialists are at greatest risk of losing mutualistic interactions because of climate change.

  4. Why Exercise Is Cool

    Science.gov (United States)

    ... to Know About Puberty Train Your Temper Why Exercise Is Cool KidsHealth > For Kids > Why Exercise Is ... day and your body will thank you later! Exercise Makes Your Heart Happy You may know that ...

  5. Waveguide cooling system

    Science.gov (United States)

    Chen, B. C. J.; Hartop, R. W.

    1981-04-01

    An improved system is described for cooling high power waveguides by the use of cooling ducts extending along the waveguide, which minimizes hot spots at the flanges where waveguide sections are connected together. The cooling duct extends along substantially the full length of the waveguide section, and each flange at the end of the section has a through hole with an inner end connected to the duct and an opposite end that can be aligned with a flange hole in another waveguide section. Earth flange is formed with a drainage groove in its face, between the through hole and the waveguide conduit to prevent leakage of cooling fluid into the waveguide. The ducts have narrowed sections immediately adjacent to the flanges to provide room for the installation of fasteners closely around the waveguide channel.

  6. Warm and Cool Dinosaurs.

    Science.gov (United States)

    Mannlein, Sally

    2001-01-01

    Presents an art activity in which first grade students draw dinosaurs in order to learn about the concept of warm and cool colors. Explains how the activity also helped the students learn about the concept of distance when drawing. (CMK)

  7. Cooling of wood briquettes

    Directory of Open Access Journals (Sweden)

    Adžić Miroljub M.

    2013-01-01

    Full Text Available This paper is concerned with the experimental research of surface temperature of wood briquettes during cooling phase along the cooling line. The cooling phase is an important part of the briquette production technology. It should be performed with care, otherwise the quality of briquettes could deteriorate and possible changes of combustion characteristics of briquettes could happen. The briquette surface temperature was measured with an IR camera and a surface temperature probe at 42 sections. It was found that the temperature of briquette surface dropped from 68 to 34°C after 7 minutes spent at the cooling line. The temperature at the center of briquette, during the 6 hour storage, decreased to 38°C.

  8. Stacking with stochastic cooling

    Energy Technology Data Exchange (ETDEWEB)

    Caspers, Fritz E-mail: Fritz.Caspers@cern.ch; Moehl, Dieter

    2004-10-11

    Accumulation of large stacks of antiprotons or ions with the aid of stochastic cooling is more delicate than cooling a constant intensity beam. Basically the difficulty stems from the fact that the optimized gain and the cooling rate are inversely proportional to the number of particles 'seen' by the cooling system. Therefore, to maintain fast stacking, the newly injected batch has to be strongly 'protected' from the Schottky noise of the stack. Vice versa the stack has to be efficiently 'shielded' against the high gain cooling system for the injected beam. In the antiproton accumulators with stacking ratios up to 10{sup 5} the problem is solved by radial separation of the injection and the stack orbits in a region of large dispersion. An array of several tapered cooling systems with a matched gain profile provides a continuous particle flux towards the high-density stack core. Shielding of the different systems from each other is obtained both through the spatial separation and via the revolution frequencies (filters). In the 'old AA', where the antiproton collection and stacking was done in one single ring, the injected beam was further shielded during cooling by means of a movable shutter. The complexity of these systems is very high. For more modest stacking ratios, one might use azimuthal rather than radial separation of stack and injected beam. Schematically half of the circumference would be used to accept and cool new beam and the remainder to house the stack. Fast gating is then required between the high gain cooling of the injected beam and the low gain stack cooling. RF-gymnastics are used to merge the pre-cooled batch with the stack, to re-create free space for the next injection, and to capture the new batch. This scheme is less demanding for the storage ring lattice, but at the expense of some reduction in stacking rate. The talk reviews the 'radial' separation schemes and also gives some

  9. Cooling of electronic equipment

    DEFF Research Database (Denmark)

    A. Kristensen, Anders Schmidt

    2003-01-01

    Cooling of electronic equipment is studied. The design size of electronic equipment decrease causing the thermal density to increase. This affect the cooling which can cause for example failures of critical components due to overheating or thermal induced stresses. Initially a pin fin heat sink...... is considered as extruded profiles are inadequate for compact designs. An optimal pin fin shape and configuration is sought also taking manufacturing costs into consideration. Standard methods for geometrical modeling and thermal analysis are applied....

  10. Anomalous law of cooling

    OpenAIRE

    Lapas, Luciano C.; Ferreira, Rogelma M. S.; Oliveira, Fernando A.; Rubí, J. Miguel

    2014-01-01

    We analyze the temperature relaxation phenomena of systems in contact with a thermal reservoir that undergo a non-Markovian diffusion process. From a generalized Langevin equation, we show that the temperature is governed by a law of cooling of the Newton's law type in which the relaxation time depends on the velocity autocorrelation and is then characterized by the memory function. The analysis of the temperature decay reveals the existence of an anomalous cooling in which the temperature ma...

  11. Cooling tower waste reduction

    Energy Technology Data Exchange (ETDEWEB)

    Coleman, S.J.; Celeste, J.; Chine, R.; Scott, C.

    1998-05-01

    At Lawrence Livermore National Laboratory (LLNL), the two main cooling tower systems (central and northwest) were upgraded during the summer of 1997 to reduce the generation of hazardous waste. In 1996, these two tower systems generated approximately 135,400 lbs (61,400 kg) of hazardous sludge, which is more than 90 percent of the hazardous waste for the site annually. At both, wet decks (cascade reservoirs) were covered to block sunlight. Covering the cascade reservoirs reduced the amount of chemical conditioners (e.g. algaecide and biocide), required and in turn the amount of waste generated was reduced. Additionally, at the northwest cooling tower system, a sand filtration system was installed to allow cyclical filtering and backflushing, and new pumps, piping, and spray nozzles were installed to increase agitation. the appurtenance upgrade increased the efficiency of the cooling towers. The sand filtration system at the northwest cooling tower system enables operators to continuously maintain the cooling tower water quality without taking the towers out of service. Operational costs (including waste handling and disposal) and maintenance activities are compared for the cooling towers before and after upgrades. Additionally, the effectiveness of the sand filter system in conjunction with the wet deck covers (northwest cooling tower system), versus the cascade reservoir covers alone (south cooling tower south) is discussed. the overall expected return on investment is calculated to be in excess of 250 percent. this upgrade has been incorporated into the 1998 DOE complex-wide water conservation project being led by Sandia National Laboratory/Albuquerque.

  12. Cooling with Superfluid Helium

    CERN Document Server

    Lebrun, P

    2014-01-01

    The technical properties of helium II (‘superfluid’ helium) are presented in view of its applications to the cooling of superconducting devices, particularly in particle accelerators. Cooling schemes are discussed in terms of heat transfer performance and limitations. Large-capacity refrigeration techniques below 2 K are reviewed, with regard to thermodynamic cycles as well as process machinery. Examples drawn from existing or planned projects illustrate the presentation. Keywords: superfluid helium, cryogenics

  13. Laser cooling of solids

    Energy Technology Data Exchange (ETDEWEB)

    Epstein, Richard I [Los Alamos National Laboratory; Sheik-bahae, Mansoor [UNM

    2008-01-01

    We present an overview of solid-state optical refrigeration also known as laser cooling in solids by fluorescence upconversion. The idea of cooling a solid-state optical material by simply shining a laser beam onto it may sound counter intuitive but is rapidly becoming a promising technology for future cryocooler. We chart the evolution of this science in rare-earth doped solids and semiconductors.

  14. Statistics Analysis Measures Painting of Cooling Tower

    Directory of Open Access Journals (Sweden)

    A. Zacharopoulou

    2013-01-01

    Full Text Available This study refers to the cooling tower of Megalopolis (construction 1975 and protection from corrosive environment. The maintenance of the cooling tower took place in 2008. The cooling tower was badly damaged from corrosion of reinforcement. The parabolic cooling towers (factory of electrical power are a typical example of construction, which has a special aggressive environment. The protection of cooling towers is usually achieved through organic coatings. Because of the different environmental impacts on the internal and external side of the cooling tower, a different system of paint application is required. The present study refers to the damages caused by corrosion process. The corrosive environments, the application of this painting, the quality control process, the measures and statistics analysis, and the results were discussed in this study. In the process of quality control the following measurements were taken into consideration: (1 examination of the adhesion with the cross-cut test, (2 examination of the film thickness, and (3 controlling of the pull-off resistance for concrete substrates and paintings. Finally, this study refers to the correlations of measurements, analysis of failures in relation to the quality of repair, and rehabilitation of the cooling tower. Also this study made a first attempt to apply the specific corrosion inhibitors in such a large structure.

  15. Stacking with Stochastic Cooling

    CERN Document Server

    Caspers, Friedhelm

    2004-01-01

    Accumulation of large stacks of antiprotons or ions with the aid of stochastic cooling is more delicate than cooling a constant intensity beam. Basically the difficulty stems from the fact that the optimized gain and the cooling rate are inversely proportional to the number of particles seen by the cooling system. Therefore, to maintain fast stacking, the newly injected batch has to be strongly protected from the Schottky noise of the stack. Vice versa the stack has to be efficiently shielded against the high gain cooling system for the injected beam. In the antiproton accumulators with stacking ratios up to 105, the problem is solved by radial separation of the injection and the stack orbits in a region of large dispersion. An array of several tapered cooling systems with a matched gain profile provides a continuous particle flux towards the high-density stack core. Shielding of the different systems from each other is obtained both through the spatial separation and via the revolution frequencies (filters)....

  16. Alternative Room Cooling System

    Directory of Open Access Journals (Sweden)

    Md. Fazle Rabbi

    2015-06-01

    Full Text Available The rapidly growing population results in an increasing demand for much more residential and commercial buildings, which leads to vertical growth of the buildings and needs proper ventilation of those buildings. Natural air ventilation system is not sufficient for conventional building structures. Hence fans and air-conditioners are must to meet the requirement of proper ventilation as well as space conditioning. Globally building sector consumes largest energy in heating, cooling, ventilation and space conditioning. This load can be minimized by the application of solar chimney and modification in building structure for heating, cooling, ventilation and space conditioning. Passive solar cooling is a subject of interest to provide cooling by using the sun, a powerful energy source. This is done for ensuring human comfort in hot climates. ASHRAE (American Society of Heating, Refrigerating and Air Conditioning Engineers defines Comfort as ‘that state of mind which expresses satisfaction with the thermal environment.’ The present paper describes the development of a solar passive cooling system, which can provide thermal cooling throughout the summer season in hot and humid climates. The constructed passive system works on natural convection mode of air. Such system reduces the inside temperature of up to 5°C from the atmospheric temperature. Temperature can further be reduced by the judicious use of night ventilation.

  17. Comparing Social Stories™ to Cool versus Not Cool

    Science.gov (United States)

    Leaf, Justin B.; Mitchell, Erin; Townley-Cochran, Donna; McEachin, John; Taubman, Mitchell; Leaf, Ronald

    2016-01-01

    In this study we compared the cool versus not cool procedure to Social Stories™ for teaching various social behaviors to one individual diagnosed with autism spectrum disorder. The researchers randomly assigned three social skills to the cool versus not cool procedure and three social skills to the Social Stories™ procedure. Naturalistic probes…

  18. Numerical simulations of material mismatch and ductile crack growth

    Energy Technology Data Exchange (ETDEWEB)

    Oestby, Erling

    2002-07-01

    Both the global geometry and inhomogeneities in material properties will influence the fracture behaviour of structures in presence of cracks. In this thesis numerical simulations have been used to investigate how some aspects of both these issues affect the conditions at the crack-tip. The thesis is organised in an introduction chapter, summarising the major findings and conclusions, a review chapter, presenting the main aspects of the developments in the field of fracture mechanics, and three research papers. Paper I considers the effect of mismatch in hardening exponent on the local near-tip stress field for stationary interface cracks in bi-materials under small scale yielding conditions. It is demonstrated that the stress level in the weaker material increases compared to what is found in the homogeneous material for the same globally applied load level, with the effect being of increasing importance as the crack-tip is approached. Although a coupling between the radial and angular dependence of the stress fields exists, the evolving stress field can still be normalised with the applied J. The effect on the increase in stress level can closely be characterised by the difference in hardening exponent, {delta}n, termed the hardening mismatch, and is more or less independent of the absolute level of hardening in the two materials. Paper II and Ill deal with the effects of geometry, specimen size, hardening level and yield stress mismatch in relation to ductile crack growth. The ductile crack growth is simulated through use of the Gurson model. In Paper H the effect of specimen size on the crack growth resistance is investigated for deep cracked bend and shallow cracked tensile specimens. At small amounts of crack growth the effect of specimen size on the crack growth resistance is small, but a more significant effect is found for larger amounts of crack growth. The crack growth resistance decreases in smaller specimens loaded in tension, whereas the opposite is

  19. Measuring the coolness of interactive products: the COOL questionnaire

    DEFF Research Database (Denmark)

    Bruun, Anders; Raptis, Dimitrios; Kjeldskov, Jesper

    2016-01-01

    characteristics. These were used to create an initial pool of question items and 2236 participants were asked to assess 16 mobile devices. By performing exploratory and confirmatory factor analyses, we identified three factors that can measure the perceived inner coolness of interactive products: desirability...... is the COOL questionnaire. We based the creation of the questionnaire on literature suggesting that perceived coolness is decomposed to outer cool (the style of a product) and inner cool (the personality characteristics assigned to it). In this paper, we focused on inner cool, and we identified 11 inner cool...

  20. Application of Cooling Water in Controlled Runout Table Cooling on Hot Strip Mill

    Institute of Scientific and Technical Information of China (English)

    LIU Zheng-dong; I V Samarasekera

    2004-01-01

    The controlled runout table cooling is essential in determining the final mechanical properties and flatness of steel strip. The heat of a hot steel strip is mainly extracted by cooling water during runout. In order to study the heat transfer by water jet impingement boiling during runout, a pilot facility was constructed at the University of British Columbia. On this pilot facility, the water jet impingement tests were carried out under various cooling conditions to investigate the effect of processing parameters, such as cooling water temperature, water jet impingement velocity, initial strip temperature, water flow rate, water nozzle diameter and array of water nozzles, on the heat transfer of heated strip. The results obtained contribute to the optimization of cooling water during runout.

  1. High stable, high efficient ultraviolet laser with angle-phase-mismatching compensation by adjusting temperature of the nonlinear crystals

    Science.gov (United States)

    Yang, Houwen; Wang, Bo; Wang, Junhua; Li, Xiaofang; Liu, Zhaojun; Cheng, Wenyong

    2017-03-01

    We demonstrated an ultraviolet laser at 355 nm using a type-I and a type-II phase-matching nonlinear optical crystal of LiB3O5 (LBO). A method of adjusting temperature for compensation is presented. The crystal temperature is controlled by proportional integral derivative (PID) thermal controllers with a  ±0.01 °C resolution. The value of wave vector mismatch, distance of light propagation in nonlinear crystals, effective nonlinear coefficient, theoretical analysis and calculation of conversion efficiency versus temperature are discussed. The experimental results show that the average output power of the 355 nm laser is 1.24 W with the pump power of 13.33 W, when the repetition frequency is 15 kHz. The pulse duration is 9.8 ns, and the beam quality factors are of Mx2   =  1.8, My2   =  1.7. The conversion efficiency from 808 nm to 355 nm laser is 9.3%, which nearly reaches the optimum value reported so far and is limited by the wavelength mismatch between the pumping and absorbing lasers. The 355 nm output power instability of the laser device is 0.45% in 2 h. A compact no-water-cooling ultraviolet laser with high stability and high efficiency is obtained.

  2. Native mass spectrometry provides direct evidence for DNA mismatch-induced regulation of asymmetric nucleotide binding in mismatch repair protein MutS

    NARCIS (Netherlands)

    M.C. Monti; S.X. Cohen (Serge); A. Fish (Alexander); H.H.K. Winterwerp (Herrie); A. Barendregt (Arjan); P. Friedhoff (Peter); A. Perrakis (Anastassis); A.J.R. Heck (Albert); T.K. Sixma (Titia); R.H.H. van den Heuvel (Robert); J.H.G. Lebbink (Joyce)

    2011-01-01

    textabstractThe DNA mismatch repair protein MutS recognizes mispaired bases in DNA and initiates repair in an ATP-dependent manner. Understanding of the allosteric coupling between DNA mismatch recognition and two asymmetric nucleotide binding sites at opposing sides of the MutS dimer requires ident

  3. Set-up and performance testing of a superconducting magnet cooled by a G-M cryocooler%G-M制冷机冷却的超导磁体研制及性能试验

    Institute of Scientific and Technical Information of China (English)

    杨志达; 刘华军; 孙浩伟; 武玉; 韩伟实

    2009-01-01

    针对超导磁体液氦易挥发、需要不断补充的问题,为研制的超导磁体加装了G-M制冷机.为了使磁体漏热量与制冷机的两级制冷量相匹配,对系统液氦和液氮温区的传导漏热、辐射漏热和对流漏热3种热载荷进行了计算,对制冷机单独进行了制冷量和最低温度的测试,结果表明磁体漏热量与制冷机制冷量相匹配.制冷机与磁体杜瓦装配后用制冷机冷却磁体,5 d时间将磁体温度冷却到4.2K.向磁体输入液氦并励磁,3 d时间内超导液面计数值下降不明显,表明磁体可实现自供液氦和零蒸发,装置在无补液情况下可长期运行.%A Gifford-McMahon (G-M) cryocooler was installed in a superconducting magnet which, due to evaporation of liquid helium, needed continuous helium replenishment. The thermal loss which was causing evaporation needed to be matched by the cooling capacity of the 1st and 2nd heads of its proposed refrigeration cryocooler. The thermal loss from conduction, radiation and convection in systemic liquid helium and the liquid helium warm area was calculated. The cooling capacity and the lowest temperature achievable by the cryocooler were also tested. Since the cryocooler was intended to cool off the magnet's cryostat, they were physically integrated. The cryostat achieved a temperature of 4.2K in five days. Field excitation and superconducting liquid level dropped insignificantly in those three days. This indicates that liquid helium can be supplied to the magnet with zero vaporization loss, allowing the magnet to run a long time without renewing liquid helium.

  4. Development of hardware simulators for tests of solar cooling/heating subsystems and systems. Phase II. Unsteady state hardware simulation of residential absorption chiller

    Energy Technology Data Exchange (ETDEWEB)

    Auh, P.C.

    1979-09-01

    The main work involves the experimental study to determine transient and cycling performance characteristics of an advanced solar absorption chiller. Laboratory tests of the second generation Arkla chiller (Solaire 36, model WF36), using the BNL simulator, have been performed. Chiller performance has also been measured against fast and slow cycling periods under both the conventional and modified control modes. The degree of performance improvement under the modified control mode, as a function of the cycle period and such effects on the integrated chiller performance, have been thoroughly investigated.

  5. Study of cover source mismatch in steganalysis and ways to mitigate its impact

    Science.gov (United States)

    Kodovský, Jan; Sedighi, Vahid; Fridrich, Jessica

    2014-02-01

    When a steganalysis detector trained on one cover source is applied to images from a different source, generally the detection error increases due to the mismatch between both sources. In steganography, this situation is recognized as the so-called cover source mismatch (CSM). The drop in detection accuracy depends on many factors, including the properties of both sources, the detector construction, the feature space used to represent the covers, and the steganographic algorithm. Although well recognized as the single most important factor negatively affecting the performance of steganalyzers in practice, the CSM received surprisingly little attention from researchers. One of the reasons for this is the diversity with which the CSM can manifest. On a series of experiments in the spatial and JPEG domains, we refute some of the common misconceptions that the severity of the CSM is tied to the feature dimensionality or their "fragility." The CSM impact on detection appears too difficult to predict due to the effect of complex dependencies among the features. We also investigate ways to mitigate the negative effect of the CSM using simple measures, such as by enlarging the diversity of the training set (training on a mixture of sources) and by employing a bank of detectors trained on multiple different sources and testing on a detector trained on the closest source.

  6. Identification of the human chromosomal region containing the iridogoniodysgenesis anomaly locus by genomic-mismatch scanning.

    Science.gov (United States)

    Mirzayans, F; Mears, A J; Guo, S W; Pearce, W G; Walter, M A

    1997-01-01

    Genome-mismatch scanning (GMS) is a new method of linkage analysis that rapidly isolates regions of identity between two genomes. DNA molecules from regions of identity by descent from two relatives are isolated based on their ability to form extended mismatch-free heteroduplexes. We have applied this rapid technology to identify the chromosomal region shared by two fifth-degree cousins with autosomal dominant iridogoniodysgenesis anomaly (IGDA), a rare ocular neurocristopathy. Markers on the short arm of human chromosome 6p were recovered, consistent with the results of conventional linkage analysis conducted in parallel, indicating linkage of IGDA to 6p25. Control markers tested on a second human chromosome were not recovered. A GMS error rate of approximately 11% was observed, well within an acceptable range for a rapid, first screening approach, especially since GMS results would be confirmed by family analysis with selected markers from the putative region of identity by descent. These results demonstrate not only the value of this technique in the rapid mapping of human genetic traits, but the first application of GMS to a multicellular organism. Images Figure 2 PMID:9245991

  7. Mismatched single stranded antisense oligonucleotides can induce efficient dystrophin splice switching

    Directory of Open Access Journals (Sweden)

    Kole Ryszard

    2011-10-01

    Full Text Available Abstract Background Antisense oligomer induced exon skipping aims to reduce the severity of Duchenne muscular dystrophy by redirecting splicing during pre-RNA processing such that the causative mutation is by-passed and a shorter but partially functional Becker muscular dystrophy-like dystrophin isoform is produced. Normal exons are generally targeted to restore the dystrophin reading frame however, an appreciable subset of dystrophin mutations are intra-exonic and therefore have the potential to compromise oligomer efficiency, necessitating personalised oligomer design for some patients. Although antisense oligomers are easily personalised, it remains unclear whether all patient polymorphisms within antisense oligomer target sequences will require the costly process of producing and validating patient specific compounds. Methods Here we report preclinical testing of a panel of splice switching antisense oligomers, designed to excise exon 25 from the dystrophin transcript, in normal and dystrophic patient cells. These patient cells harbour a single base insertion in exon 25 that lies within the target sequence of an oligomer shown to be effective at removing exon 25. Results It was anticipated that such a mutation would compromise oligomer binding and efficiency. However, we show that, despite the mismatch an oligomer, designed and optimised to excise exon 25 from the normal dystrophin mRNA, removes the mutated exon 25 more efficiently than the mutation-specific oligomer. Conclusion This raises the possibility that mismatched AOs could still be therapeutically applicable in some cases, negating the necessity to produce patient-specific compounds.

  8. Screening for mutations in kidney-related genes using SURVEYOR nuclease for cleavage at heteroduplex mismatches.

    Science.gov (United States)

    Voskarides, Konstantinos; Deltas, Constantinos

    2009-07-01

    SURVEYOR is a new mismatch-specific plant DNA endonuclease that is very efficient for mutation scanning in heteroduplex DNA. It is much faster, cheaper, more sensitive, and easier to perform than other "traditional" mutation detection methods such as single-strand conformation polymorphism analysis, denaturing high-performance liquid chromatography, heteroduplex analysis, and phage resolvases. This is the first comprehensive report on the use of SURVEYOR for screening genes implicated in a spectrum of inherited renal diseases. Of the 48.2 kb screened, 44 variations were identified, accounting for one variation per 1.1 kb. The re-sequencing of multiple samples did not reveal any variation that had not been identified by SURVEYOR, attesting to its high fidelity. Additionally, we tested this enzyme against 15 known variants, 14 of which it identified, thus showing a sensitivity of 93%. We showed that the genetic heterogeneity of renal diseases can be easily overcome using this enzyme with a high degree of confidence and no bias for any specific variations. We also showed for the first time that SURVEYOR does not demonstrate any preference regarding mismatch cleavage at specific positions. Disadvantages of using SURVEYOR include enhanced exonucleolytic activity for some polymerase chain reaction products and less than 100% sensitivity. We report that SURVEYOR can be used as a mutation detection method with a high degree of confidence, offering an excellent alternative for low-budget laboratories and for the rapid manipulation of multiple genes.

  9. The definition of cool

    Energy Technology Data Exchange (ETDEWEB)

    Nichiporuk, A.

    2005-05-01

    A new air cooling system at Agnico-Eagle's LaRonde mine, located in the Abitibi Region of Quebec is described. The new system serves a mine operating at 7,250 plus feet level. The system is installed at the surface; it utilizes ammonia to cool water, which cools the air. The system consists of four compressors which lower the temperature of the ammonia to minus 2 degrees C. Water, which at this temperature is 14 degrees, and ammonia pass through a plate heat exchanger simultaneously, however, without coming into contact with each other. The heat transfer that occurs causes the water's temperature to drop to 2 degrees C. The total volume of water cooled is 220 litres per second. The system is capable of reducing 636,000 cfm of air from 30 degrees C to 6 degrees C, to which 214,000 cfm of non-cooled air is added. This mixture, which is maintained at approximately 8 degrees C throughout the summer season, is sent underground to the deepest parts of the mine. The system runs from June to September, depending on the weather. In the evenings, when the temperature dips to around four to five degrees C, the water is shut down and side doors are opened to prevent the water from freezing.

  10. Film cooling enhancement with surface restructure

    Science.gov (United States)

    Chen, Shuping

    Discrete-hole film cooling is used extensively in turbine components. In past decades, many research works concerning this technique have been published. Recently, efforts have been directed at seeking technologies that would increase film cooling effectiveness. Particularly, surface reshaping through protective coatings, such as a thermal barrier coating (TBC), is very attractive to turbine designers because extra machining work is not needed for its application. In the present work, film cooling enhancement with surface restructure is experimentally studied using an infrared (IR) imaging technique. The first surface structure studied is the surface with flow-aligned blockers. The studied configurations include single-hole and three-hole-row structures. The single-hole case is used for studying the effects of blocker design parameters, which include blocker height (0.2D, 0.4D, and 0.6D), distance between two neighboring blockers (0.8D, D, and 1.2D), blocker length (2", 4", and 6"), and blowing ratio M (0.43 and 0.93). The design with the best performance is chosen for the three-hole-row cases. The second surface shape studied, is the so-called upstream ramp, which is placed in front of a row of film cooling holes. Investigated geometrical parameters include upstream ramp angles (8.5°, 15°, and 24°) and blowing ratio M (0.29, 0.43, 0.57, 0.93, and 1.36). Detailed local film cooling effectiveness and heat transfer coefficient are measured using an IR imaging technique. The third film cooling concept is the so-called trenched film cooling holes, i.e., film cooling holes sitting in a transverse groove. The film cooling structure for this experimental test consists of a three-hole row embedded in a trench 0.5D in depth and 2D in width, where D is the diameter of the holes. Five blowing ratios (0.29, 0.43, 0.57, 0.93, and 1.36) are tested. Based on the tested results, the three film cooling schemes are also compared. To implement the experimental work, a test system

  11. Silicon micro-fluidic cooling for NA62 GTK pixel detectors

    CERN Document Server

    Romagnoli, G; Brunel, B; Catinaccio, A; Degrange, J; Mapelli, A; Morel, M; Noel, J; Petagna, P

    2015-01-01

    Silicon micro-channel cooling is being studied for efficient thermal management in application fields such as high power computing and 3D electronic integration. This concept has been introduced in 2010 for the thermal management of silicon pixel detectors in high energy physics experiments. Combining the versatility of standard micro-fabrication processes with the high thermal efficiency typical of micro-fluidics, it is possible to produce effective thermal management devices that are well adapted to different detector configurations. The production of very thin cooling devices in silicon enables a minimization of material of the tracking sensors and eliminates mechanical stresses due to the mismatch of the coefficient of thermal expansion between detectors and cooling systems. The NA62 experiment at CERN will be the first high particle physics experiment that will install a micro-cooling system to perform the thermal management of the three detection planes of its Gigatracker pixel detector.

  12. Physiologic and Functional Responses of MS Patients to Body Cooling Using Commercially Available Cooling Garments

    Science.gov (United States)

    Ku, Yu-Tsuan E.; Montgomery, Leslie D.; Lee, Hank C.; Luna, Bernadette; Webbon, Bruce W.; Mead, Susan C. (Technical Monitor)

    1999-01-01

    Personal cooling systems are widely used in industrial and aerospace environments to alleviate thermal stress. Increasingly they are also used by heat sensitive multiple sclerosis (HSMS) patients to relieve symptoms and improve quality of life. There are a variety of cooling systems commercially available to the MS community. However, little information is available regarding the comparative physiological changes produced by routine operation of these various systems. The objective of this study was to document and compare the patient response to two passive cooling vests and one active cooling garment. The Life Enhancement Technology, Inc. (LET) lightweight active cooling vest with cap, the MicroClimate Systems (MCS) Change of Phase garment, and the Steele Vest were each used to cool 13 male and 13 female MS subjects (31 to 67 yr.) in this study. The subjects, seated in an upright position at normal room temperature (approximately 22 C), were tested with one of the cooling garments. Oral, fight and left ear temperatures were logged manually every 5 min. An-n, leg, chest and rectal temperatures; heart rate; and respiration were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. Each subject was given a series of subjective and objective evaluation tests before and after cooling. The LET and Steele vests test groups had similar, significant (P less than 0.01) cooling effects on oral and ear canal temperature, which decreased approximately 0.4 C, and 0.3 C, respectively. Core temperature increased (N.S.) with all three vests during cooling. The LET vest produced the coldest (P less than 0.01) skin temperature. Overall, the LET vest provided the most improvement on subjective and objective performance measures. These results show that the garment configurations tested do not elicit a similar thermal response in all MS patients. Cooling with the LET active garment configuration resulted in the lowest body temperatures for the MS subjects; cooling with

  13. Single-molecule multiparameter fluorescence spectroscopy reveals directional MutS binding to mismatched bases in DNA

    NARCIS (Netherlands)

    M. Cristovao (Michele); E. Sisamakis (Evangelos); M.M. Hingorani (Manju); A.D. Marx (Andreas); C.P. Jung (Caroline); P.J. Rothwell (Paul); C.A.M. Seidel (Claus A.); P. Friedhoff (Peter)

    2012-01-01

    textabstractMismatch repair (MMR) corrects replication errors such as mismatched bases and loops in DNA. The evolutionarily conserved dimeric MMR protein MutS recognizes mismatches by stacking a phenylalanine of one subunit against one base of the mismatched pair. In all crystal structures of G:T mi

  14. Single-molecule multiparameter fluorescence spectroscopy reveals directional MutS binding to mismatched bases in DNA

    NARCIS (Netherlands)

    M. Cristovao (Michele); E. Sisamakis (Evangelos); M.M. Hingorani (Manju); A.D. Marx (Andreas); C.P. Jung (Caroline); P.J. Rothwell (Paul); C.A.M. Seidel (Claus A.); P. Friedhoff (Peter)

    2012-01-01

    textabstractMismatch repair (MMR) corrects replication errors such as mismatched bases and loops in DNA. The evolutionarily conserved dimeric MMR protein MutS recognizes mismatches by stacking a phenylalanine of one subunit against one base of the mismatched pair. In all crystal structures of G:T

  15. Aspects of Household Cooling Technology

    OpenAIRE

    Mrzyglod, Matthias; Holzer, Stefan

    2014-01-01

    Actually available household cooling appliances in the highest efficiency class may consume less then 10W average electrical power. To achieve such power consumptions special challenges for the cooling system had to overcome. The related cooling system design has to consider several effects, which arise from the corresponding low cooling capacity demand, start/stop cycles and additional power consumptions by control accessories. The lecture provides symptomatic aspects of cooling technology, ...

  16. Mismatch negativity, social cognition, and functional outcomes in patients after traumatic brain injury

    Directory of Open Access Journals (Sweden)

    Hui-yan Sun

    2015-01-01

    Full Text Available Mismatch negativity is generated automatically, and is an early monitoring indicator of neuronal integrity impairment and functional abnormality in patients with brain injury, leading to decline of cognitive function. Antipsychotic medication cannot affect mismatch negativity. The present study aimed to explore the relationships of mismatch negativity with neurocognition, daily life and social functional outcomes in patients after brain injury. Twelve patients with traumatic brain injury and 12 healthy controls were recruited in this study. We examined neurocognition with the Wechsler Adult Intelligence Scale-Revised China, and daily and social functional outcomes with the Activity of Daily Living Scale and Social Disability Screening Schedule, respectively. Mismatch negativity was analyzed from electroencephalogram recording. The results showed that mismatch negativity amplitudes decreased in patients with traumatic brain injury compared with healthy controls. Mismatch negativity amplitude was negatively correlated with measurements of neurocognition and positively correlated with functional outcomes in patients after traumatic brain injury. Further, the most significant positive correlations were found between mismatch negativity in the fronto-central region and measures of functional outcomes. The most significant positive correlations were also found between mismatch negativity at the FCz electrode and daily living function. Mismatch negativity amplitudes were extremely positively associated with Social Disability Screening Schedule scores at the Fz electrode in brain injury patients. These experimental findings suggest that mismatch negativity might efficiently reflect functional outcomes in patients after traumatic brain injury.

  17. Mismatch negativity, social cognition, and functional outcomes in patients after traumatic brain injury

    Institute of Scientific and Technical Information of China (English)

    Hui-yan Sun; Qiang Li; Xi-ping Chen; Lu-yang Tao

    2015-01-01

    Mismatch negativity is generated automatically, and is an early monitoring indicator of neuronal integrity impairment and functional abnormality in patients with brain injury, leading to decline of cognitive function. Antipsychotic medication cannot affect mismatch negativity. The present study aimed to explore the relationships of mismatch negativity with neurocognition, daily life and social functional outcomes in patients after brain injury. Twelve patients with traumatic brain injury and 12 healthy controls were recruited in this study. We examined neurocogni-tion with the Wechsler Adult Intelligence Scale-Revised China, and daily and social functional outcomes with the Activity of Daily Living Scale and Social Disability Screening Schedule, re-spectively. Mismatch negativity was analyzed from electroencephalogram recording. The results showed that mismatch negativity amplitudes decreased in patients with traumatic brain injury compared with healthy controls. Mismatch negativity amplitude was negatively correlated with measurements of neurocognition and positively correlated with functional outcomes in patients after traumatic brain injury. Further, the most signiifcant positive correlations were found be-tween mismatch negativity in the fronto-central region and measures of functional outcomes. The most signiifcant positive correlations were also found between mismatch negativity at the FCz electrode and daily living function. Mismatch negativity amplitudes were extremely positive-ly associated with Social Disability Screening Schedule scores at the Fz electrode in brain injury patients. These experimental ifndings suggest that mismatch negativity might efifciently relfect functional outcomes in patients after traumatic brain injury.

  18. Doppler cooling a microsphere

    CERN Document Server

    Barker, P F

    2010-01-01

    Doppler cooling the center-of-mass motion of an optically levitated microsphere via the velocity dependent scattering force from narrow whispering gallery mode (WGM) resonances is described. Light that is red detuned from the WGM resonance can be used to damp the center-of-mass motion in a process analogous to the Doppler cooling of atoms. Leakage of photons out of the microsphere when the incident field is near resonant with the narrow WGM resonance acts to damp the motion of the sphere. The scattering force is not limited by saturation, but can be controlled by the incident power. Cooling times on the order of seconds are calculated for a 20 micron diameter silica microsphere trapped within optical tweezers, with a Doppler temperature limit in the microKelvin regime.

  19. Natural radiative cooling

    Energy Technology Data Exchange (ETDEWEB)

    Lazzarin, R.

    1979-01-01

    Natural radiative cooling at night was measured based on the surface-radiation spectrum after the heat balance of the surface exposed to the sun had been reradiated. A concept equivalent to the sky temperature and a concept useful for obtaining the net heat flux are discussed. The highest possible equilibrium temperature of the selective surface can be lowered; however, how to apply this practically is not yet known. A simple radiator, completely enclosed by a transparent screen, can produce a significant and inexpensive cooling effect. The results of experiments carried out in an area such as Padua, Italy, where the climate is not suitable for cooling purposes can still be predicted theoretically. The possibility of using the collector for heat collection during the day and as a radiator at night is indicated.

  20. Clean cooling; Saubere Kuehlung

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1998-07-01

    The round hybrid cooling towers which Balcke-Duerr GmbH is currently building for the 550-MW-IGCC-power-station of a refinery project on Sardinia have to meet particularly stringent requirements as seawater is used for cooling. The advantages are: Avoidance of visible plume with minimal energy consumption, optimal plume exit velocity and discharge, greatest possible stability of the plume column, avoidance of interference and recirculation, high operating reliability of the cooling tower. (orig.) [Deutsch] Derzeit werden die Kuehltuerme fuer ein 550-MW-IGCC-Kraftwerk einer Raffinierie auf Sardinien errichtet. Die Anforderungen an die Technik sind hoch, denn gekuehlt wird mit Seewasser. Zum Einsatz kommen Hybridrundkuehltuerme der Balcke-Duerr GmbH, Ratingen. Damit setzt das Unternehmen diesen Typ erstmals ausserhalb von Deutschland ein. (orig.)

  1. Monitoring Cray Cooling Systems

    Energy Technology Data Exchange (ETDEWEB)

    Maxwell, Don E [ORNL; Ezell, Matthew A [ORNL; Becklehimer, Jeff [Cray, Inc.; Donovan, Matthew J [ORNL; Layton, Christopher C [ORNL

    2014-01-01

    While sites generally have systems in place to monitor the health of Cray computers themselves, often the cooling systems are ignored until a computer failure requires investigation into the source of the failure. The Liebert XDP units used to cool the Cray XE/XK models as well as the Cray proprietary cooling system used for the Cray XC30 models provide data useful for health monitoring. Unfortunately, this valuable information is often available only to custom solutions not accessible by a center-wide monitoring system or is simply ignored entirely. In this paper, methods and tools used to harvest the monitoring data available are discussed, and the implementation needed to integrate the data into a center-wide monitoring system at the Oak Ridge National Laboratory is provided.

  2. A comparison of surface wave tomography in the Atlantic Ocean with the plate model: mismatches and implications for the lithosphere-asthenosphere system

    Science.gov (United States)

    Fishwick, S.; Crosby, A. G.

    2009-12-01

    The oceans should be one of the most straightforward regions within which to investigate the lithosphere-asthenosphere boundary, because their thermal structure appears to be so simple. However, this assertion assumes our present understanding of the oceanic lithosphere is correct, which is derived principally from observations of heat flow and subsidence beneath the ocean floor. These observations show large positive deviations from half-space cooling models after 60-80 Ma, which indicate that conductive cooling does not continue forever as the plate moves away from the ridge. Instead, data from the oldest ocean floor are better fit by a thermal plate model with a thickness of 90-100 km, which is gently modulated by convection within the upper mantle. The physical interpretation of the fixed temperature basal boundary condition is that heat is supplied to the base of the plate by small-scale convection in the thermal boundary layer underlying the rigid lid. We compare the expected shear velocities given the plate cooling model with the velocities observed from surface wave tomography. Tomographic data sets for both Africa and South America have been combined to place constraints on the velocity structure beneath the Atlantic Ocean. The velocities observed in the tomography are faster than expected at lithospheric depths, and an age-velocity relationship continues to around 125km - a depth at which the plate model predicts uniform temperatures. Some aspect of these discrepancies could be due to the vertical parameterisation and smearing within the surface wave tomography. To test this possibility, we compare the dispersion characteristics for the theoretical model with the surface wave dispersion data, and also observe a similar mismatch. A more likely source of error is the conversion between velocity and temperature, particularly given our limited knowledge of the attenuation structure of the region. These results have important implications for our understanding

  3. Research on Cooling Effectiveness in Stepped Slot Film Cooling Vane

    Institute of Scientific and Technical Information of China (English)

    LI Yulong; WU Hong; ZHOU Feng; RONG Chengjun

    2016-01-01

    As one of the most important developments in air cooling technology for hot parts of the aero-engine,film cooling technology has been widely used.Film cooling hole structure exists mainly in areas that have high temperature,uneven cooling effectiveness issues when in actual use.The first stage turbine vanes of the aero-engine consume the largest portion of cooling air,thereby the research on reducing the amount of cooling air has the greatest potential.A new stepped slot film cooling vane with a high cooling effectiveness and a high cooling uniformity was researched initially.Through numerical methods,the affecting factors of the cooling effectiveness of a vane with the stepped slot film cooling structure were researched.This paper focuses on the cooling effectiveness and the pressure loss in different blowing ratio conditions,then the most reasonable and scientific structure parameter can be obtained by analyzing the results.The results show that 1.0 mm is the optimum slot width and 10.0 is the most reasonable blowing ratio.Under this condition,the vane achieved the best cooling result and the highest cooling effectiveness,and also retained a low pressure loss.

  4. Approaches to diagnose DNA mismatch repair gene defects in cancer

    DEFF Research Database (Denmark)

    Peña-Diaz, Javier; Rasmussen, Lene Juel

    2016-01-01

    The DNA repair pathway mismatch repair (MMR) is responsible for the recognition and correction of DNA biosynthetic errors caused by inaccurate nucleotide incorporation during replication. Faulty MMR leads to failure to address the mispairs or insertion deletion loops (IDLs) left behind...... already been well defined and their pathogenicity assessed. Despite this substantial wealth of knowledge, the effects of a large number of alterations remain uncharacterized (variants of uncertain significance, VUSs). The advent of personalized genomics is likely to increase the list of VUSs found in MMR...

  5. Quasisynchronization in Quorum Sensing Systems with Parameter Mismatches

    Directory of Open Access Journals (Sweden)

    Jianbao Zhang

    2014-01-01

    Full Text Available The paper investigates quasisynchronization in a communication system, which consists of cells communicating through quorum sensing. With the help of Lyapunov function method and Lur’e system approach, some sufficient conditions for quasisynchronization are presented, and a bound on the synchronization errors is derived. The obtained theoretical results show that the synchronization quality is influenced by two parameters detrimentally: the error bound depends almost linearly on the mismatches between cells and depends sensitively on the diffusion rates of the signals inward the cell membrane. Numerical experiments are carried out to verify the theoretical results.

  6. Optimal control design that accounts for model mismatch errors

    Energy Technology Data Exchange (ETDEWEB)

    Kim, T.J. [Sandia National Labs., Albuquerque, NM (United States); Hull, D.G. [Texas Univ., Austin, TX (United States). Dept. of Aerospace Engineering and Engineering Mechanics

    1995-02-01

    A new technique is presented in this paper that reduces the complexity of state differential equations while accounting for modeling assumptions. The mismatch controls are defined as the differences between the model equations and the true state equations. The performance index of the optimal control problem is formulated with a set of tuning parameters that are user-selected to tune the control solution in order to achieve the best results. Computer simulations demonstrate that the tuned control law outperforms the untuned controller and produces results that are comparable to a numerically-determined, piecewise-linear optimal controller.

  7. Phoneme discrimination and mismatch negativity in English and Japanese speakers

    OpenAIRE

    Bomba, Marie D.; Choly, David; Elizabeth W Pang

    2011-01-01

    Neural templates for phonemes in one’s native language are formed early in life; these can be modified but are difficult to form de novo. These can be examined with mismatch negativity. Three phonemic contrasts were presented to adult native English compared to Japanese speakers who acquired English later: vowels native to both languages (/i//iy/); consonant-vowel contrasts (/da//wa/) phonemic in both languages; and consonant-vowel contrasts phonemic in English but not in Japanese (/ra//la/)....

  8. Anomalous law of cooling.

    Science.gov (United States)

    Lapas, Luciano C; Ferreira, Rogelma M S; Rubí, J Miguel; Oliveira, Fernando A

    2015-03-14

    We analyze the temperature relaxation phenomena of systems in contact with a thermal reservoir that undergoes a non-Markovian diffusion process. From a generalized Langevin equation, we show that the temperature is governed by a law of cooling of the Newton's law type in which the relaxation time depends on the velocity autocorrelation and is then characterized by the memory function. The analysis of the temperature decay reveals the existence of an anomalous cooling in which the temperature may oscillate. Despite this anomalous behavior, we show that the variation of entropy remains always positive in accordance with the second law of thermodynamics.

  9. Anomalous law of cooling

    Science.gov (United States)

    Lapas, Luciano C.; Ferreira, Rogelma M. S.; Rubí, J. Miguel; Oliveira, Fernando A.

    2015-03-01

    We analyze the temperature relaxation phenomena of systems in contact with a thermal reservoir that undergoes a non-Markovian diffusion process. From a generalized Langevin equation, we show that the temperature is governed by a law of cooling of the Newton's law type in which the relaxation time depends on the velocity autocorrelation and is then characterized by the memory function. The analysis of the temperature decay reveals the existence of an anomalous cooling in which the temperature may oscillate. Despite this anomalous behavior, we show that the variation of entropy remains always positive in accordance with the second law of thermodynamics.

  10. Superconductor rotor cooling system

    Science.gov (United States)

    Gamble, Bruce B.; Sidi-Yekhlef, Ahmed; Schwall, Robert E.; Driscoll, David I.; Shoykhet, Boris A.

    2002-01-01

    A system for cooling a superconductor device includes a cryocooler located in a stationary reference frame and a closed circulation system external to the cryocooler. The closed circulation system interfaces the stationary reference frame with a rotating reference frame in which the superconductor device is located. A method of cooling a superconductor device includes locating a cryocooler in a stationary reference frame, and transferring heat from a superconductor device located in a rotating reference frame to the cryocooler through a closed circulation system external to the cryocooler. The closed circulation system interfaces the stationary reference frame with the rotating reference frame.

  11. A Cool Emperor Penguin

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    哇,这只帝企鹅的胸前居然有个心形!It’s cool!(乐天:没错,它的胸前少了这幺撮毛,应该会感觉挺凉快的)cool在这里可不是“凉快”的意思,而是“酷.帅气”的意思。我们《英语大王》的英文名字就叫English Cool Kids哦!(乐天拿出一副墨镜戴上:

  12. Gas cooled fast reactor

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1972-06-01

    Although most of the development work on fast breeder reactors has been devoted to the use of liquid metal cooling, interest has been expressed for a number of years in alternative breeder concepts using other coolants. One of a number of concepts in which interest has been retained is the Gas-Cooled Fast Reactor (GCFR). As presently envisioned, it would operate on the uranium-plutonium mixed oxide fuel cycle, similar to that used in the Liquid Metal Fast Breeder Reactor (LMFBR), and would use helium gas as the coolant.

  13. Quantum thermodynamic cooling cycle

    CERN Document Server

    Palao, J P; Gordon, J M; Palao, Jose P.; Kosloff, Ronnie; Gordon, Jeffrey M.

    2001-01-01

    The quantum-mechanical and thermodynamic properties of a 3-level molecular cooling cycle are derived. An inadequacy of earlier models is rectified in accounting for the spontaneous emission and absorption associated with the coupling to the coherent driving field via an environmental reservoir. This additional coupling need not be dissipative, and can provide a thermal driving force - the quantum analog of classical absorption chillers. The dependence of the maximum attainable cooling rate on temperature, at ultra-low temperatures, is determined and shown to respect the recently-established fundamental bound based on the second and third laws of thermodynamics.

  14. DEVELOPMENT OF SINGLE-PHASED WATER-COOLING RADIATOR FOR COMPUTER CHIP

    Institute of Scientific and Technical Information of China (English)

    ZENG Ping; CHENG Guangming; LIU Jiulong; YANG Zhigang; SUN Xiaofeng; PENG Taijiang

    2007-01-01

    In order to cool computer chip efficiently with the least noise, a single phase water-cooling radiator for computer chip driven by piezoelectric pump with two parallel-connection chambers is developed. The structure and work principle of this radiator is described. Material, processing method and design principles of whole radiator are also explained. Finite element analysis (FEA) software,ANSYS, is used to simulate the heat distribution in the radiator. Testing equipments for water-cooling radiator are also listed. By experimental tests, influences of flowrate inside the cooling system and fan on chip cooling are explicated. This water-cooling radiator is proved more efficient than current air-cooling radiator with comparison experiments. During cooling the heater which simulates the working of computer chip with different power, the water-cooling radiator needs shorter time to reach lower steady temperatures than current air-cooling radiator.

  15. OVERPREDICTION OF FEAR IN PANIC DISORDER PATIENTS WITH AGORAPHOBIA - DOES THE (MIS)MATCH MODEL GENERALIZE TO EXPOSURE IN-VIVO THERAPY

    NARCIS (Netherlands)

    VANHOUT, WJPJ; EMMELKAMP, PMG

    1994-01-01

    The purpose of this study was to test the (mis)match model of Rachman and co-workers during real life exposure therapy in panic disorder patients with agoraphobic avoidance. The results showed that although the patients tended to overpredict their expected fear before the exposure sessions, their pr

  16. Overprediction of fear in panic disorder patients with agoraphobia: Does the (mis)match model generalize to exposure in vivo therapy?

    NARCIS (Netherlands)

    van Hout, W.J.P.J.; Emmelkamp, P.M.G.

    1994-01-01

    The purpose of this study was to test the (mis)match model of Rachman and co-workers during real life exposure therapy in panic disorder patients with agoraphobic avoidance. The results showed that although the patients tended to overpredict their expected fear before the exposure sessions, their pr

  17. 冷却速率对无铅再流焊焊点质量的影响(待续)%Effect of Cooling Rate on Solder Joint Quality In Lead-free Reflow Soldering

    Institute of Scientific and Technical Information of China (English)

    史建卫

    2012-01-01

    Cooling rate affects mechanic property and reliability of solder joint markedly in lead-free reflow soldering.Rapid cooling rate can fine structure,control indirectly thickness and modality of intermetallic compound,affect failure style and reinforce performance of solder joint,but stress induced by mismatching between components and PCB materials brings about invalidation of produce.Summarize the work of documents and projects a experiment of oven cooling,air cooling and water cooling for reflow soldering,test solder joints strength and analyze metallograph of interface compound as well.The optimums cooling rate is 3 to 6 Celsius per seconds in electronic industry.%无铅再流焊中冷却速率影响焊点力学性能及可靠性。快速冷却可以细化组织,间接控制金属间化合物厚度和形态,影响焊点断裂模式,提高焊点综合性能。但是由于元件与PCB等材料的热不匹配性而造成的较大应力,易造成元件或焊点失效等。通过对文献中研究结果的总结,设计了炉冷、空冷和水冷等几种再流焊冷却方式,并对焊点进行了强度测试和组织成分分析,建议工业用最佳冷却斜率控制在3℃/s~6℃/s。

  18. 冷却速率对无铅再流焊焊点质量的影响(待续)%Effect of Cooling Rate on Solder Joint Quality In Lead-free Reflow Soldering

    Institute of Scientific and Technical Information of China (English)

    史建卫

    2011-01-01

    Cooling rate affects mechanic property and reliability of solder joint markedly in lead-free reflow soldering.Rapid cooling rate can fine structure,control indirectly thickness and modality of intermetallic compound,affect failure style and reinforce performance of solder joint,but stress induced by mismatching between components and PCB materials brings about invalidation of produce.Summarize the work of documents and projects a experiment of oven cooling,air cooling and water cooling for reflow soldering,tests solder joints strength and analyze metallograph of interface compound as well.The optimums cooling rate is 3 to 6 Celsius per seconds in electronic industry.%无铅再流焊中冷却速率影响焊点力学性能及可靠性。快速冷却可以细化组织,间接控制金属间化合物厚度和形态,影响焊点断裂模式,提高焊点综合性能。但是由于元件与PCB等材料的热不匹配性而造成的较大应力,易造成元件或焊点失效等。通过对文献中研究结果的总结,设计了炉冷、空冷和水冷等几种再流焊冷却方式,并对焊点进行了强度测试和组织成分分析,建议最佳冷却斜率控制在3℃/s~6℃/s。

  19. 冷却速率对无铅再流焊焊点质量的影响(续完)%Effect of Cooling Rate on Solder Joint Quality In Lead-free Reflow Soldering

    Institute of Scientific and Technical Information of China (English)

    史建卫

    2012-01-01

    Cooling rate affects mechanic property and reliability of solder joint markedly in lead-free reflow soldering. Rapid cooling rate can fine structure, control indirectly thickness and modality of intermetallic compound, affect failure style and reinforce performance of solder joint, but stress induced by mismatching between components and PCB materials brings about invalidation of produce. Summarize the work of documents and projects a experiment of oven cooling, air cooling and water cooling for reflow soldering, test solder joints strength and analyze metallograph of interface compound as well. The optimums cooling rate is 3 to 6 Celsius per seconds in electronic industry,%无铅再流焊中冷却速率影响焊点力学性能及可靠性。快速冷却可以细化组织,间接控制金属间化合物厚度和形态,影响焊点断裂模式,提高焊点综合性能。但是由于元件与PCB等材料的热不匹配性而造成的较大应力,易造成元件或焊点失效等。通过对文献中研究结果的总结,设计了炉冷、空冷和水冷等几种再流焊冷却方式,并对焊点进行了强度测试和组织成分分析,建议工业用最佳冷却斜率控制在3℃/s~6℃/s。

  20. Toward a phenological mismatch in estuarine pelagic food web?

    Science.gov (United States)

    Chevillot, Xavier; Drouineau, Hilaire; Lambert, Patrick; Carassou, Laure; Sautour, Benoit; Lobry, Jérémy

    2017-01-01

    Alterations of species phenology in response to climate change are now unquestionable. Until now, most studies have reported precocious occurrence of life cycle events as a major phenological response. Desynchronizations of biotic interactions, in particular predator-prey relationships, are however assumed to strongly impact ecosystems’ functioning, as formalized by the Match-Mismatch Hypothesis (MMH). Temporal synchronicity between juvenile fish and zooplankton in estuaries is therefore of essential interest since estuaries are major nursery grounds for many commercial fish species. The Gironde estuary (SW France) has suffered significant alterations over the last three decades, including two Abrupt Ecosystem Shifts (AES), and three contrasted intershift periods. The main objective of this study was to depict modifications in fish and zooplankton phenology among inter-shift periods and discuss the potential effects of the resulting mismatches at a community scale. A flexible Bayesian method was used to estimate and compare yearly patterns of species abundance in the estuary among the three pre-defined periods. Results highlighted (1) an earlier peak of zooplankton production and entrance of fish species in the estuary and (2) a decrease in residence time of both groups in the estuary. Such species-specific phenological changes led to changes in temporal overlap between juvenile fish and their zooplanktonic prey. This situation questions the efficiency and potentially the viability of nursery function of the Gironde estuary, with potential implications for coastal marine fisheries of the Bay of Biscay. PMID:28355281