WorldWideScience

Sample records for cooling equipment air-conditioners

  1. Stirling Air Conditioner for Compact Cooling

    Energy Technology Data Exchange (ETDEWEB)

    None

    2010-09-01

    BEETIT Project: Infinia is developing a compact air conditioner that uses an unconventional high efficient Stirling cycle system (vs. conventional vapor compression systems) to produce cool air that is energy efficient and does not rely on polluting refrigerants. The Stirling cycle system is a type of air conditioning system that uses a motor with a piston to remove heat to the outside atmosphere using a gas refrigerant. To date, Stirling systems have been expensive and have not had the right kind of heat exchanger to help cool air efficiently. Infinia is using chip cooling technology from the computer industry to make improvements to the heat exchanger and improve system performance. Infinia’s air conditioner uses helium gas as refrigerant, an environmentally benign gas that does not react with other chemicals and does not burn. Infinia’s improvements to the Stirling cycle system will enable the cost-effective mass production of high-efficiency air conditioners that use no polluting refrigerants.

  2. 48 CFR 52.223-12 - Refrigeration Equipment and Air Conditioners.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 2 2010-10-01 2010-10-01 false Refrigeration Equipment... Provisions and Clauses 52.223-12 Refrigeration Equipment and Air Conditioners. As prescribed in 23.804(b), insert the following clause: Refrigeration Equipment and Air Conditioners (MAY 1995) The Contractor...

  3. Methodology for uncertainty calculation of net total cooling effect estimation for rating room air conditioners and packaged terminal air conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Fonseca Diaz, Nestor [Universidad Tecnologica de Pereira, Facultad de Ingenieria Mecanica, Pereira (Colombia); University of Liege, Campus du Sart Tilman, Bat: B49, P33, B-4000 Liege (Belgium)

    2009-09-15

    This article presents the general procedure for uncertainty calculation of net total cooling effect estimation for rating room air conditioners and packaged terminal air conditioners, by means of measurements carried out in a test bench specially designed for this purpose. The uncertainty analysis presented in this work looks for establishing a confidence degree or certainty of experimental results. It is particularly important considering that international standards related to this type of analysis are too ambiguous when treating this subject. The uncertainty analysis is on the other hand an indispensable requirement to international standard ISO 17025 [ISO, 2005. International Standard. 17025. General Requirement to Test and Calibration Laboratories Competences. International Organization for Standardization, Geneva.], which must be applied to obtain the required quality levels according to the Word Trade Organization WTO. (author)

  4. Application of evaporative cooling on the condenser of window-air-conditioner

    Energy Technology Data Exchange (ETDEWEB)

    Hajidavalloo, Ebrahim [Shahid Chamran University, Department of Mechanical Engineering, Golestan St., Ahwaz, Khoozestan 61355 (Iran, Islamic Republic of)]. E-mail: hajidae_1999@yahoo.com

    2007-08-15

    Reduction of energy consumption is a major concern in the vapor compression refrigeration cycle especially in the area with very hot weather conditions (about 50 deg. C), where window-air-conditioners are usually used to cool homes. In this weather condition performance of air condenser window-air-conditioners decrease sharply and electrical power consumption increase considerably. These problems have activated the research programs in order to improve the performance of window-air-conditioners by enhancing heat transfer rate in the condenser. In this article, a new design with high commercialization potential for incorporating of evaporative cooling in the condenser of window-air-conditioner is introduced and experimentally investigated. A real air conditioner is used to test the innovation by putting two cooling pads in both sides of the air conditioner and injecting water on them in order to cool down the air before it passing over the condenser. The experimental results show that thermodynamic characteristics of new system are considerably improved and power consumption decreases by about 16% and the coefficient of performance increases by about 55%.

  5. 16 CFR Appendix H to Part 305 - Cooling Performance and Cost for Central Air Conditioners

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Cooling Performance and Cost for Central Air Conditioners H Appendix H to Part 305 Commercial Practices FEDERAL TRADE COMMISSION REGULATIONS UNDER SPECIFIC... Manufacturer's rated cooling capacities (Btu's/hr.) Range of SEER's Low High Single Package Units Central Air...

  6. Experimental study on split air conditioner with new hybrid equipment of energy storage and water heater all year round

    Energy Technology Data Exchange (ETDEWEB)

    Wang Shaowei [School of Mechanical and Power Engineering, Shanghai Jiao Tong University, Shanghai 200030 (China)]. E-mail: wswtop@sjtu.edu.cn; Liu Zhenyan [School of Mechanical and Power Engineering, Shanghai Jiao Tong University, Shanghai 200030 (China); Li Yuan [Qingdao Hisense Group Co. Ltd., Qingdao 266030 (China); Zhao Keke [Qingdao Hisense Group Co. Ltd., Qingdao 266030 (China); Wang Zhigang [Qingdao Hisense Group Co. Ltd., Qingdao 266030 (China)

    2005-11-15

    This paper presents a split air conditioner with a new hybrid equipment of energy storage and water heater all year round (ACWES). The authors made a special design on the storage tank to adjust the refrigerant capacity in the storage coils under different functions, instead of adding an accumulator to the system. An ACWES prototype, rebuilt from an original split air conditioner, has been finished, and experimental study of the operation processes of the prototype was done from which some important conclusions and suggestions have been made, which were helpful in the primary design and improvement of an ACWES system for potential users.

  7. ENERGY STAR Certified Non-AHRI Central Air Conditioner Equipment and Air Source Heat Pump

    Science.gov (United States)

    Certified models meet all ENERGY STAR requirements as listed in the Version 5.0 ENERGY STAR Program Requirements for Air Source Heat Pump and Central Air Conditioner Equipment that are effective as of September 15, 2015. A detailed listing of key efficiency criteria are available at http://www.energystar.gov/index.cfm?c=airsrc_heat.pr_crit_as_heat_pumps Listed products have been submitted to EPA by ENERGY STAR partners that do not participate in the AHRI certification program. EPA will continue to update this list with products that are certified by EPA-recognized certification bodies other than AHRI. The majority of ENERGY STAR products, certified by AHRI, can be found on the CEE/AHRI Verified Directory at http://www.ceedirectory.org/

  8. ENERGY STAR Certified Non-AHRI Central Air Conditioner Equipment and Air Source Heat Pump

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 5.0 ENERGY STAR Program Requirements for Air Source Heat Pump and Central Air Conditioner...

  9. Cooling the Planet: Opportunities for Deployment of Superefficient Room Air Conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Nihar [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Waide, Paul [Navigant Consulting Inc., Chicago, IL (United States); Phadke, Amol [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2013-04-01

    This report presents the results of an analysis, commissioned by the U.S. Department of Energy, of Air Conditioner (AC) efficiency in support of the Super-efficient Equipment and Appliance Deployment (SEAD) initiative.1 The International Energy Studies group at Lawrence Berkeley National Laboratory in collaboration with Navigant Consulting Inc. performed the analysis. SEAD aims to transform the global market by increasing the penetration of highly efficient equipment and appliances. SEAD partners work together in voluntary activities to: (1) “raise the efficiency ceiling” by pulling superefficient appliances and equipment into the market through cooperation on measures like incentives, procurement, awards, and research and development (R&D) investments; (2) “raise the efficiency floor” by working together to bolster national or regional policies like minimum efficiency standards; and (3) “strengthen the efficiency foundations” of programs by coordinating technical work to support these activities.2 The objective of this analysis is to provide the background technical information necessary to improve the efficiency of ACs and to provide a foundation for the activities of SEAD participating countries. We find that even the best currently available technology offers large efficiency improvement opportunities (35% to 50% reduction in energy consumption from the market average) in most SEAD countries. The cost effective efficiency improvements range from 20% to 30% reduction in energy consumption based on a consumer perspective.

  10. 大型空调器节能装置%Large Air-conditioner Energy-saving Equipment

    Institute of Scientific and Technical Information of China (English)

    刘扶岗; 李征涛; 李振华

    2012-01-01

    基于传统空调器性能测试台温度控制的原理,提出一种大型空调器节能实验装置,并简单介绍了该装置的节能原理。该试验台与传统空调器性能测试台不同的是在空气处理系统中加入了热回收换热器,有效利用室内外机室热回收换热器的热量来满足温度控制要求,从而减少了电加热器的能耗,节省了能源。%Based on the principle of temperature control of traditional air conditioner performance-testing bench, a new energy-saving equipment for large air conditioner is put forward. The energy saving principle of this equipment has been simply introduced. A heat recovery exchanger is put in the air handling system compared with the traditional air-conditioner laboratory. It is used to heat the air satisfying the demands for the temperature control in testing room, reducing the consumption of electric heaters and saving energy.

  11. Performance evaluation of a stack cooling system using CO{sub 2} air conditioner in fuel cell vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Chul; Won, Jong Phil [Thermal Management Research Center, Korea Automotive Technology Institute, Chungnam 330-912 (Korea); Park, Yong Sun; Lim, Tae Won [Corporate Research and Development Division, Hyundai-Kia Motors, Gyeonggi 449-912 (Korea); Kim, Min Soo [School of Mechanical and Aerospace Engineering, Seoul National University, Seoul 151-744 (Korea)

    2009-01-15

    A relation between the heat release from a fuel cell stack and an air conditioning system's performance was investigated. The air conditioning system installed in a fuel cell vehicle can be used for stack cooling when additional stack heat release is required over a fixed radiator capacity during high vehicle power generation. This study investigated the performance of a stack cooling system using CO{sub 2} air conditioner at various operating conditions. Also, the heat releasing effectiveness and mutual interference were analyzed and compared with those for the conventional radiator cooling system with/without cabin cooling. When the radiator coolant inlet temperature and flow rate were 65 C and 80 L/min, respectively, for the outdoor air inlet speed of 5 m/s, the heat release of the stack cooling system with the aid of CO{sub 2} air conditioner increased up to 36% more than that of the conventional radiator cooling system with cabin cooling. Furthermore, this increased by 7% versus the case without cabin cooling. (author)

  12. Unitary and room air-conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Christian, J.E.

    1977-09-01

    The scope of this technology evaluation on room and unitary air conditioners covers the initial investment and performance characteristics needed for estimating the operating cost of air conditioners installed in an ICES community. Cooling capacities of commercially available room air conditioners range from 4000 Btu/h to 36,000 Btu/h; unitary air conditioners cover a range from 6000 Btu/h to 135,000 Btu/h. The information presented is in a form useful to both the computer programmer in the construction of a computer simulation of the packaged air-conditioner's performance and to the design engineer, interested in selecting a suitably sized and designed packaged air conditioner.

  13. Semi-empiric model of an air cooled cabinet air conditioner for the dynamic analysis of the building and acclimation systems integrated behaviour; Modelo semi-empirico de condicionador de gabinete resfriado a ar para analise dinamica do comportamento integrado de edificacoes e sistemas de climatizacao

    Energy Technology Data Exchange (ETDEWEB)

    Correa, Jorge E. [Para Univ., Belem (Brazil). Dept. de Engenharia Mecanica]. E-mail: jecorrea@amazon.com.br; Melo, Claudio. E-mail: melo@nrva.ufsc.br; Negrao, Cezar O. R. E-mail: negrao@energia.damec.cefetpr.br

    2000-07-01

    This work presents a semi-empirical model for a air cooled case air conditioner. This model is to be inserted in the EPS-r program (Environmental System Performance - research version) allowing the dynamic analysis of the integrated behaviour of buildings and acclimation systems using this equipment. Results obtained from simulations under the operation conditions existing in Brazil are analysed.

  14. High-efficiency gas heat pump air-conditioner equipped with absorption refrigerator

    Science.gov (United States)

    Imai, Yosuke; Ohashi, Toshinori; Okamoto, Hiroaki; Hihara, Eiji; Kawakami, Ryuichiro

    On conventional gas heat pump(GHP), waste heat from gas engine that uses as driving source is emitted into outside. So from the standpoint of efficient use of waste heat, it is assumed that waste heat from gas engine is used as driving source of absorption chiller, and high temperature condensate refrigerant in GHP is subcooled to middle temperature by cold source from absorption cycle, and as a result, GHP makes more efficiency. However, in equipping GHP with absorption cycle, downsizing and high-efficiency of absorption cycle is required. In this study, air-cooled subcooled adiabatic absorber is focused and physical phenomenon in it is analyzed, and finally one perception of the optimized designing is shown.

  15. New and Green Multi-component Scaling and Corrosion Inhibitor for the Cooling Water of Central Air Conditioners

    Science.gov (United States)

    Li, Maodong; Dai, Chenlin; Yang, Bo; Qiao, Yue; Zhu, Zhiping

    2016-12-01

    A green multi-component inhibitor was developed in this study to obtain suitable scale and corrosion inhibitor for the cooling water treatment of central air conditioners. The inhibitor formulation consisted of hydrolyzed polymaleic anhydride/Tween-80/sodium N-lauroyl sarcosinate/tolyltriazole (named 4-HTSA). Weight loss test and electrochemical method were used to investigate the corrosion inhibition performance of 4-HTSA on A3 carbon steel and T2 red copper in synthetic cooling water, and the scale inhibition performance of 4-HTSA was studied by the calcium carbonate precipitation method. The influence of parameters, such as pH, temperature, scaling and corrosive ion, on 4-HTSA was researched. Scanning electron microscopy (SEM) and x-ray diffraction were used for examination of the scale, and corrosion coupons were analyzed by SEM/energy-dispersive x-ray spectroscopy. Results showed that 4-HTSA had excellent scale and corrosion inhibition performance and wide tolerance to pH, temperature and the concentration of scaling and corrosive ion. Polarization curves indicated that 4-HTSA was anodic inhibitor.

  16. Performance analysis of a ground-assisted direct evaporative cooling air conditioner

    Energy Technology Data Exchange (ETDEWEB)

    Heidarinejad, Ghassem; Khalajzadeh, Vahid [Department of Mechanical Engineering, Tarbiat Modares University, P.O. Box 14115-143, Tehran (Iran); Delfani, Shahram [Building and Housing Research Center (BHRC), P O Box 13145-1696, Tehran (Iran)

    2010-11-15

    In this paper, the results of performance analysis of a ground-assisted hybrid evaporative cooling system in Tehran have been discussed. A Ground Coupled Circuit (GCC) provides the necessary pre-cooling effects, enabling a Direct Evaporative Cooler (DEC) that cools the air even below its wet-bulb temperature. The GCC includes four vertical ground heat exchangers (GHE) which were arrayed in series configuration. In order to have an accurate prediction of the optimum performance of a GCC, a computational fluid dynamic simulation was performed. Simulation results revealed that the combination of GCC and DEC system could provide comfort condition whereas DEC alone did not. Based on the simulation results the cooling effectiveness of a hybrid system is more than 100%. Thus, this novel hybrid system could decrease the air temperature below the ambient wet-bulb temperature. This environmentally clean and energy efficient system can be considered as an alternative to the mechanical vapor compression systems. (author)

  17. Preliminary design package for residential heating/cooling system--Rankine air conditioner redesign

    Energy Technology Data Exchange (ETDEWEB)

    1978-12-01

    This report contains a summary of the preliminary redesign and development of a marketable single-family heating and cooling system. The objectives discussed are the interim design and schedule status of the Residential (3-ton) redesign, problem areas and solutions, and the definition of plans for future design and development activities. The proposed system for a single-family residential heating and cooling system is a single-loop, solar-assisted, hydronic-to-warm-air heating subsystem with solar-assisted domestic water heating and a Rankine-driven expansion air-conditioning subsystem.

  18. Preliminary design package for residential heating/cooling system: Rankine air conditioner redesign

    Science.gov (United States)

    1978-01-01

    A summary of the preliminary redesign and development of a marketable single family heating and cooling system is presented. The interim design and schedule status of the residential (3-ton) redesign, problem areas and solutions, and the definition of plans for future design and development activities were discussed. The proposed system for a single-family residential heating and cooling system is a single-loop, solar-assisted, hydronic-to-warm-air heating subsystem with solar-assisted domestic water heating and a Rankine-driven expansion air-conditioning subsystem.

  19. On the performance of air conditioner with heat pipe for cooling air in the condenser

    Energy Technology Data Exchange (ETDEWEB)

    Naphon, Paisarn, E-mail: paisarnn@swu.ac.t [Thermo-Fluids and Heat Transfer Enhancement Laboratory (TFHT), Department of Mechanical Engineering, Faculty of Engineering, Srinakharinwirot University, 63 Rangsit-Nakhornnayok Rd., Ongkharak, Nakhorn-Nayok 26120 (Thailand)

    2010-11-15

    Improvement of the air conditioning system performance by using the heat pipe for cooling air before entering the condenser is presented. In the experiment, the heat pipe is fabricated from the straight copper tube with the diameter and length of 10, 600 mm, respectively. The arrangements of the heat pipe sets are arranged in the staggered layout with the tube rows of 1, 2, 3. R134a refrigerant is used as working fluid in the heat pipe set for this present study. By comparing with a conventional air conditioning system, the air conditioning system with three rows of heat pipe gives the highest COP and EER with increasing of 6.4%, 17.5%, respectively. On the global warming and environment problems, the results of this study are expected to lead to guidelines that will allow the improved performance of the air conditioning systems which reduce its energy consumption.

  20. Dynamic Free Cooling. Efficient and energy saving air conditioner for datahotels; Dynamic Free Cooling. Efficient en energeibesparend airconditioningsysteem voor datacenters

    Energy Technology Data Exchange (ETDEWEB)

    Havenaar, D.

    2009-01-15

    Servers in data centres produce a large amount of heat, which has to be removed by ventilation and air conditioning systems. These systems have a vast energy consumption. Increasing energy costs and limited resources of available electricity are forcing the data centre industry to the use of energy efficient technical equipment. Dynamic Free Cooling is a contrN concept for data centre's air conditioning systems combining Hybrid Indirect Free Cooling Precision Air Conditiening Units, Fan Speed Controlled Dry Coolers and Speed Controlled Central Pumps to highly efficient precision cooling system. All system components are centrally controlled to minimize overall energy consumption depending on the Ambient Temperature and the Room Load Status. [Dutch] Servers in datacenters produceren een grote hoeveelheid warmte die moet worden afgevoerd door middel van ventilatie- en airconditioningsystemen. Deze systemen gebruiken een forse hoeveelheid elektrische energie. Toenemende energiekosten en de beperkte beschikbaarheid van elektriciteit zorgen ervoor dat datacenters steeds meer overgaan op het installeren van energie-efficiente systemen. Dynamic Free Cooling is een regelconcept voor airconditioningsystemen in combinatie met hybride indirecte vrije koeling in precisie-airconditioningunits, ventilatorgeregetde droge koelers en toerengeregetde centrale pompsystemen. AI deze systeemcomponenten worden centraal geregeld om het totale energiegebruik, afhankelijk van de omgevingstemperatuur en de koellast te minimaliseren.

  1. 77 FR 8178 - Test Procedures for Central Air Conditioners and Heat Pumps: Public Meeting

    Science.gov (United States)

    2012-02-14

    ...; ] DEPARTMENT OF ENERGY 10 CFR Part 430 Test Procedures for Central Air Conditioners and Heat Pumps: Public... discuss methodologies and gather comments on testing residential central air conditioners and heat pumps... residential central air conditioners and heat pumps that are single phase with rated cooling capacities less...

  2. 风冷式与水冷式单元空调机组的对比%Comparison between air-cooled and water-cooled unitary air conditioners

    Institute of Scientific and Technical Information of China (English)

    赵丽

    2012-01-01

    从不同方面比较了风冷式和水冷式单元空调机组的优缺点,包括机组能效比、名义工况冷源综合制冷性能系数、机房面积以及对总体建筑环境的影响.指出了对于大型会展建筑中冷热负荷具有临时性的空调区域,分散式风冷单元空调机组有较好的发展前景.%Compares the advantages and disadvantages of air-cooled and water-cooled unitary air conditioners from different aspects including the unit EER, the overall nominal working condition refrigerating coefficient of performance, the area of machine room, and the influence on the building environment. Points out that to the areas in convention and exhibition buildings with temporary cooling/ heating loads, there will be a better prospect for the decentralized air-cooled unitary air conditioners.

  3. 电子机柜空调器%Electronic Control Cabinet Air Conditioner

    Institute of Scientific and Technical Information of China (English)

    张强

    2014-01-01

    该文介绍了一种小型电子机柜空调器的设计方案,该空调器解决了密闭电子机柜散热的问题,能够在较小尺寸下达到1000W的制冷量,实现对相对密闭电子机柜小环境内温湿度的有效控制,提高机柜内电子设备的可靠性。%This paper introduces the design of a small electronic cabinet air-conditioner, the air-conditioner solves the sealed electronic cabinet cooling problems, have the cooling capacity of 1000W at a smaller size, realize the effective control of the rela-tive closed electronic cabinet small environment temperature and humidity, to improve the reliability of electronic equipment cabinet.

  4. China’s Three Giants in Air Conditioner Manufacturing Reduced Production to Cut Excessive Inventory

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    <正>Midea,Haier and Gree,China’s three giants in air conditioner manufacturing who have been troubled by an excessive inventory due to a cool summer this year,have cut their produc- tions,marking a premature end to the huge de- mand in China’s air conditioner market lasting for three consecutive years.Currently the whole industry has an inventory of more than 10 million air conditioners.

  5. EnerGuide room air conditioner directory 2004 : energy ratings for room air conditioners[Includes Energy Star qualified room air conditioners

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-04-01

    This guide lists all room air conditioners sold in Canada and offers advice on how to buy an energy efficient model as labelled under the EnerGuide rating system. The EnerGuide label is regulated under Canada's Energy Efficiency Regulations and is designed to help consumers estimate the annual electricity cost of running an appliance. The EnerGuide compares the energy consumption or energy efficiency of major household appliances and room air conditioners. The EnerGuide label displays a bar scale with an arrow that positions the model compared to the most energy-efficient and least energy efficient models in the same class. The EnerGuide concept uses standardized methods, in which all models of appliances sold in Canada are tested to determine their yearly energy use. The EnerGuide program was developed to protect the environment by reducing the demand for energy in Canada and to help consumers spend less money on energy. This simple guide allows consumers to determine the exact size of room air conditioner they need to meet their cooling needs. It was noted that the operating cost of a room air conditioner will vary depending on the climate, the energy efficiency rating of the air conditioner, temperature setting of the unit, fan operation and the local cost of electricity. The guide includes tables which reveal the energy consumption in kWh by province during the cooling season. tabs.

  6. Implementation of a model for the reduction of latent capacity of an air-conditioner at part-load conditions with continuous fan operation

    Energy Technology Data Exchange (ETDEWEB)

    Haddad, K.H.; Blake, J. [Natural Resources Canada, Ottawa, ON (Canada). CANMET Energy Technology Centre

    2004-07-01

    The performance of air-conditioners and their moisture removal effectiveness is degraded when the indoor circulation fan is in continuous mode and the compressor is off. Early experiments have shown that when the compressor is off, the cooling coil acts as an evaporative cooler and vapour condensates on its surface. This vapour goes back into the air stream and back to the conditioned space, resulting in higher humidity levels. A model has been developed by previous examiners to predict the degradation of the performance of the air-conditioner. The model accounts for the conditions of the air entering the coil, thermostat cycling rate, air-conditioner transient performance, and the moisture-retaining characteristics of the cooling coil. However, this model has not been used within a building energy simulation program. This paper demonstrates how the model can be used as part of an air-conditioning model in the ESP-r/HOT3000 building energy analysis program. Within ESP-r/HOT3000, the model can determine the effect of moisture evaporation from the coil, during compressor off-cycle within continuous fan operation. It can also examine the effect on temperature and relative humidity inside a residential building during the cooling season. The model can also determine the effect of equipment latent capacity degradation on electricity use by air conditioners. The study identifies the problems associated with an over-sized air conditioner. 5 refs., 3 tabs., 7 figs.

  7. The Study of the Legionella pneumophila Pollution and Killing Effects on Centralized Air-conditioners Cooling Circulating Water in Huizhou City%惠州市中央空调冷却循环水中嗜肺军团菌污染状况和杀灭效果观察

    Institute of Scientific and Technical Information of China (English)

    郑惠东; 杨建秀; 郑丽萍; 戴昌芳; 辜少红; 严琦瑞; 柯晓明

    2012-01-01

    Objective To understand the Legionella pneumophila pollution and the effects of killing Legionella pneumophila by electrolyzed water of Centralized Air Ventilation System in Huizhou City.Methods We culture and identify 123 units Legionella pneumophila,which collecting in the Centralized Air-conditioners cooling circulation water of Huizhou.A new type of low-voltage high-frequency electrolytic water equipment is applied by Guang Zhou Shui Li Qing Environmental Protection Technology Co.,Ltd.It can use physical way instead of chemicals to deal with Legionella pneumophila and other pathogenic microorganisms in cooling circulating water in centralized air-conditioners.Results In the survey of 123 units,448 water samples were collected,313 samples were prove out that contain Legionella pneumophila,the detection rate is 69.86%.At the same time,62 units which contain Legionella pneumophila were collected from Centralized Air-conditioners and deal with low voltage high frequency Electrolyzed Water equipment for 7-73 d.Finally,112 water samples,which from those units,were found out that all the Legionella pneumophila had been killed.The sterilizing rate for the Legionella pneumophila is 100%.Conclusion Part of Centralized Air-conditioners Cooling Circulating Water were Pollution by Legionella pneumophila in Huizhou,Daily inspection should be taken,The low-voltage high-frequency electrolytic water equipment can effectively control and sterilize Legionella pneumophila etc in the cooling water and chilled water in centralized air-conditioners.It has a good application prospect for this technology.%目的 了解惠州市中央空调冷却循环水中嗜肺军团菌污染情况和电解水对其的杀灭效果观察.方法 对惠州市123个单位中央空调冷却循环水进行嗜肺军团菌的培养和鉴定;然后采用源自广州水力清环保科技有限公司的新型低压高频电解水处理器,用物理方式代替化学药剂,处理中央空调冷却循环水

  8. 10 CFR 431.92 - Definitions concerning commercial air conditioners and heat pumps.

    Science.gov (United States)

    2010-01-01

    ... heat pumps. 431.92 Section 431.92 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Commercial Air Conditioners and Heat Pumps § 431.92 Definitions concerning commercial air conditioners and heat pumps. The following definitions apply...

  9. A Review of Solar Desiccant Air Conditioner

    Directory of Open Access Journals (Sweden)

    Dr. U. V. Kongre, D. P. Mahure, P. A. Zamre

    2014-04-01

    Full Text Available This paper represents a detailed study and description of a new solar-based air-conditioning technique. It uses solar energy to produce cold or hot air. This technology can be used to reduce the energy consumption and environmental impact of mechanical cooling system. The use of Desiccant cooling is used to perform air dehumidification operation by utilizing low grade heat source. The solar desiccant air conditioner uses solar power as the main energy source to help in the thermodynamic heat transfer process as well as heat transfer principles to convert ambient air into cooling air. With our constructed design we have seen temperature as well as humidity level drops throughout the desiccant cooling system. A significant advantage of this system is, it have no moving parts consequently they are noiseless, non-corrosive, cheap to maintain, long lasting in addition to being environmentally friendly with zero ozone depletion as well as zero global warming potentials.

  10. Rooftop Unitary Air Conditioner with Integral Dedicated Outdoor Air System

    Energy Technology Data Exchange (ETDEWEB)

    Tiax Llc

    2006-02-28

    Energy use of rooftop and other unitary air-conditioners in commercial applications accounts for about 1 quad (10{sup 15} Btu) of primary energy use annually in the U.S. [Reference 7]. The realization that this cooling equipment accounts for the majority of commercial building cooled floorspace and the majority also of commercial building energy use has spurred development of improved-efficiency equipment as well as development of stricter standards addressing efficiency levels. Another key market driver affecting design of rooftop air-conditioning equipment has been concern regarding comfort and the control of humidity. Trends for increases in outdoor air ventilation rates in certain applications, and the increasing concern about indoor air quality problems associated with humidity levels and moisture in buildings points to a need for improved dehumidification capability in air-conditioning equipment of all types. In many cases addressing this issue exacerbates energy efficiency, and vice versa. The integrated dedicated outdoor air system configuration developed in this project addresses both energy and comfort/humidity issues.

  11. Experimental Analysis on Solar Desiccant Air Conditioner

    Directory of Open Access Journals (Sweden)

    Dr. U. V. Kongre, C. M. Singh, A. B. Biswas

    2014-05-01

    Full Text Available The experiment investigated and evaluated the feasibility of an solar desiccant air conditioner. Its effectiveness as a possible air conditioner option used in household air conditioner or as an energy efficient and environmentally friendly alternative to conventional air conditioning units used in houses are evaluated. A solar water heater was used as heat gain. The model utilizes the technology of solar air conditioner system. The purpose in the long term would be reduced the consumption of electricity used for air conditioning, reduce harmful emission and hence saving money.

  12. Zero Carryover Liquid-Desiccant Air Conditioner for Solar Applications: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Lowenstein, A.; Slayzak, S.; Kozubal, E.

    2006-07-01

    A novel liquid-desiccant air conditioner that dries and cools building supply air will transform the use of direct-contact liquid-desiccant systems in HVAC applications, improving comfort, air quality, and providing energy-efficient humidity control.

  13. Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 1, Methodology

    Energy Technology Data Exchange (ETDEWEB)

    1993-11-01

    The Energy Policy and Conservation Act (P.L. 94-163), as amended, establishes energy conservation standards for 12 of the 13 types of consumer products specifically covered by the Act. The legislation requires the Department of Energy (DOE) to consider new or amended standards for these and other types of products at specified times. DOE is currently considering amending standards for seven types of products: water heaters, direct heating equipment, mobile home furnaces, pool heaters, room air conditioners, kitchen ranges and ovens (including microwave ovens), and fluorescent light ballasts and is considering establishing standards for television sets. This Technical Support Document presents the methodology, data, and results from the analysis of the energy and economic impacts of the proposed standards. This volume presents a general description of the analytic approach, including the structure of the major models.

  14. Improved Modeling of Residential Air Conditioners and Heat Pumps for Energy Calculations

    Energy Technology Data Exchange (ETDEWEB)

    Cutler, D.; Winkler, J.; Kruis, N.; Christensen, C.; Brendemuehl, M.

    2013-01-01

    This report presents improved air conditioner and heat pump modeling methods in the context of whole-building simulation tools, with the goal of enabling more accurate evaluation of cost effective equipment upgrade opportunities and efficiency improvements in residential buildings.

  15. LDDX: A High Efficiency Air Conditioner for DOD Buildings

    Science.gov (United States)

    2017-02-01

    remove moisture by overcooling the process air and so is expected to use 30% less electricity than conventional systems in applications with very...that are wetted with a liquid desiccant, move moisture from the process air to the cooling air . The pressure drop through the desiccant-wetted pads...as a conventional DX air conditioner (with slightly higher fan power due to the pressure drops across the inactive absorber and desorber pads). The

  16. Laboratory Performance Testing of Residential Window Air Conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Winkler, J.; Booten, C.; Christensen, D.; Tomerlin, J.

    2013-03-01

    Window air conditioners are the dominant cooling product for residences, in terms of annual unit sales. They are inexpensive, portable and can be installed by the owner. For this reason, they are an attractive solution for supplemental cooling, for retrofitting air conditioning into a home which lacks ductwork, and for renters. Window air conditioners for sale in the United States are required to meet very modest minimum efficiency standards. Four window air conditioners' performance were tested in the Advanced HVAC Systems Laboratory on NREL's campus in Golden, CO. In order to separate and study the refrigerant system's performance, the unit's internal leakage pathways, the unit's fanforced ventilation, and the leakage around the unit resulting from installation in a window, a series of tests were devised that focused on each aspect of the unit's performance. These tests were designed to develop a detailed performance map to determine whole-house performance in different climates. Even though the test regimen deviated thoroughly from the industry-standard ratings test, the results permit simple calculation of an estimated rating for both capacity and efficiency that would result from a standard ratings test. Using this calculation method, it was found that the three new air conditioners' measured performance was consistent with their ratings. This method also permits calculation of equivalent SEER for the test articles. Performance datasets were developed across a broad range of indoor and outdoor operating conditions, and used them to generate performance maps.

  17. Experimental investigation on thermoelectric air conditioner driven by solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Xu Lizhen; Li Yan; Qin Feng; Chen Changhe [Key Lab. for Thermal Science and Power Engineering, Ministry of Education of China, Dept. of Thermal Engineering, Tsinghua Univ., BJ (China)

    2008-07-01

    The thermoelectric devices can convert solar energy into a temperature difference to act as coolers or heater with the help of PV arrays, especially in the remote area without power network. The experiment device is composed of thermoelectric refrigeration modules, fan, air channel, cooling cabinet and temperature measurement system. The thermoelectric air conditioner (TEAC) system is tested with different working electric voltage of thermopile; its operational parameters are obtained for different operational conditions. The Coefficient of Performance (COP) is analyzed in experimental ways. The factors that affect the efficiency of TEAC are discussed on the basis of experimental investigation by air-cooled thermoelectric module and water-cooled thermoelectric module. (orig.)

  18. Control Technologies for Room Air-conditioner and Packaged Air-conditioner

    Science.gov (United States)

    Ito, Nobuhisa

    Trends of control technologies about air-conditioning machineries, especially room or packaged air conditioners, are presented in this paper. Multiple air conditioning systems for office buildings are mainly described as one application of the refrigeration cycle control technologies including sensors for thermal comfort and heating/ cooling loads are also described as one of the system control technologies. Inverter systems and related technologies for driving variable speed compressors are described in both case of including induction motors and brushless DC motors. Technologies for more accurate control to meet various kind of regulations such as ozone layer destruction, energy saving and global warming, and for eliminating harmonic distortion of power source current, as a typical EMC problem, will be urgently desired.

  19. Influence of local air velocity from air conditioner evaluated by salivary and skin biomarkers

    Energy Technology Data Exchange (ETDEWEB)

    Yamaguchi, Masaki; Takahashi, Takayuki; Yoshino, Yuichiro; Sasaki, Makoto [Graduate School of Engineering, Iwate University, 4-3-5 Ueda, Morioka 020-8551 (Japan); Nishimiya, Hajime [Asahi Kasei Homes Corporation, R and D Laboratories, 2-1 Samejima, Fuji, Shizuoka 416-8501 (Japan)

    2010-11-15

    The purpose of this paper is to reveal both the psychosomatic and the physical effects of local air velocity from an air conditioner using biomarkers which can be collected noninvasively. Salivary {alpha}-amylase activity (SAA) and salivary cortisol were used as the indexes of psychosomatic effects. The total protein (TP) collected from stratum corneum was used as an index of the physical condition of dry skin. A continuous experiment over a 5 days period in summer was conducted using 8 healthy young male adults for 2-types of airflow conditioners, a whole ceiling-type air conditioner (without local air velocity) and a normal-type air conditioner (with local air velocity). The subjects felt cool, windy, dry and uncomfortable when under the normal-type air conditioner as determined in a subjective evaluation. The SAA under the normal-type air conditioner fluctuated more widely than with the whole ceiling-type air conditioner. The level of salivary cortisol decreased more in a day under the normal-type air conditioner than with the whole ceiling-type air conditioner. These results showed that reducing local air velocity may provide more healthy psychosomatic conditions over the long-term. Moreover, the TP of a drying-exposed skin area showed a significant change during this experiment whereas the TP of drying-protected area was relatively unchanged. It was indicated that one week's exposure to local air velocity conditions possibly influences the drying of facial skin. Thus, air movement at low velocity can be provides more comfortable conditions not only psychosomatically but also physically. (author)

  20. Design of heat recovery system for a split air-conditioner

    Energy Technology Data Exchange (ETDEWEB)

    Narayanan, R.; Pundoor, M. [Curtin Univ. of Technology, Miri, Sarawak (Malaysia)

    2007-07-01

    The growth in demand for electrical energy is far exceeding the growth of the power supply. There is a significant demand to reduce energy consumption by all means. There is also a greater demand for energy efficient equipment. Although most houses have separate cooling and water heating systems, this paper demonstrated that air conditioning units and a water heaters can be combined. For example, the heat recovered from the condenser of an air-conditioner can be effectively used to heat water which can offer significant savings in electricity consumption. With the design of a heat recovery system, a percentage of heat rejected from an air conditioning unit can be reclaimed for heating. The paper presented the working principles including a system diagram of a combined air conditioner and hot water generation system. It also discussed the conceptual designs of a heat reclaim module. The six different design concepts were then presented. Design selection and criteria for design selection were also identified along with the advantages and limitations of each concept. Based on a comprehensive analysis and research with the help of a Pugh chart of convergence matrix, the final concept was chosen. 9 refs., 1 tab., 8 figs.

  1. High Efficiency Room Air Conditioner

    Energy Technology Data Exchange (ETDEWEB)

    Bansal, Pradeep [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-01-01

    This project was undertaken as a CRADA project between UT-Battelle and Geberal Electric Company and was funded by Department of Energy to design and develop of a high efficiency room air conditioner. A number of novel elements were investigated to improve the energy efficiency of a state-of-the-art WAC with base capacity of 10,000 BTU/h. One of the major modifications was made by downgrading its capacity from 10,000 BTU/hr to 8,000 BTU/hr by replacing the original compressor with a lower capacity (8,000 BTU/hr) but high efficiency compressor having an EER of 9.7 as compared with 9.3 of the original compressor. However, all heat exchangers from the original unit were retained to provide higher EER. The other subsequent major modifications included- (i) the AC fan motor was replaced by a brushless high efficiency ECM motor along with its fan housing, (ii) the capillary tube was replaced with a needle valve to better control the refrigerant flow and refrigerant set points, and (iii) the unit was tested with a drop-in environmentally friendly binary mixture of R32 (90% molar concentration)/R125 (10% molar concentration). The WAC was tested in the environmental chambers at ORNL as per the design rating conditions of AHAM/ASHRAE (Outdoor- 95F and 40%RH, Indoor- 80F, 51.5%RH). All these modifications resulted in enhancing the EER of the WAC by up to 25%.

  2. Cooling of electronic equipment

    DEFF Research Database (Denmark)

    A. Kristensen, Anders Schmidt

    2003-01-01

    Cooling of electronic equipment is studied. The design size of electronic equipment decrease causing the thermal density to increase. This affect the cooling which can cause for example failures of critical components due to overheating or thermal induced stresses. Initially a pin fin heat sink...... is considered as extruded profiles are inadequate for compact designs. An optimal pin fin shape and configuration is sought also taking manufacturing costs into consideration. Standard methods for geometrical modeling and thermal analysis are applied....

  3. Application of central air conditioner system on modular drilling rig of offshore ifxed platform%集中空调系统在海洋固定平台模块钻机上的应用研究

    Institute of Scientific and Technical Information of China (English)

    罗立臣; 许瑞杰; 马冬辉

    2014-01-01

    Based on the air conditioner selection of Lu Feng7-2 oil ifeld modular drilling rig project, this paper determines two sets of selection of air conditioner by preliminary study, which are central and separation air conditioner systems, respectively. With comparison between the central air conditioner and the split air conditioner in cost, effciency, comfort, space, etc., it concludes that the central air conditioner system has the advantages of lower operation cost, higher energy effciency ratio, better comfort capability, smaller space occupation and so on. It also analyzes its superiority and prospect of application on the modular drilling rig of offshore ifxed platform, which can provide a certain reference for the room cooling design and the equipment selection.%结合陆丰7-2油田模块钻机项目空调选型,通过前期调查研究制定了两套空调选型方案:集中空调系统方案和分体空调系统方案。通过对比两者在费用、工作效率、舒适性、占用空间等方面的特点,得出集中空调系统具有初始投入及运行成本低、能效比高、舒适性好、占地面积小等方面的优点,并分析了集中空调在海洋固定平台模块钻机上使用的优越性以及应用前景,对海洋固定平台模块钻机的房间制冷设计及设备选型提供了一定的参考。

  4. Analysis and optimization of an adsorption air conditioner for electric vehicle applications

    Energy Technology Data Exchange (ETDEWEB)

    Aceves, S.M.

    1994-07-27

    This paper shows an analysis of the applicability of an adsorption system for electric vehicle (EV) air conditioning. Adsorption systems are designed and optimized to provide the required cooling for four combinations of vehicle characteristics and driving cycles. The resulting adsorption systems are compared with vapor compression air conditioners that can satisfy the cooling load. The objective function is the overall system weight, which includes the cooling system weight and the weight of the battery necessary to provide energy for air conditioner operation. The system with the minimum overall weight is considered to be the best. The results show the optimum values of all the variables, as well as temperatures and amounts adsorbed, for the adsorption and desorption processes. The results indicate that, for the conditions analyzed in this paper, vapor compression air conditioners are superior to adsorption systems, not only because they are lighter, but also because they have a higher COP and are more compact.

  5. Research on a compact adsorption room air conditioner

    Energy Technology Data Exchange (ETDEWEB)

    Yang, G.Z.; Xia, Z.Z.; Wang, R.Z.; Keletigui, Daou; Wang, D.C. [Institute of Refrigeration and Cryogenics, Shanghai Jiao Tong University, 1954 Huashan Road, Shanghai 200030 (China); Dong, Z.H.; Yang, X. [Panasonic R and D Center, Suzhou Co., Ltd., Suzhou 215000 (China)

    2006-09-15

    A novel compact adsorption room air conditioner with a cooling capacity of 1kW has been designed, and two prototypes have been built. A two bed, continuous adsorption refrigeration cycle with heat recovery and mass recovery is adopted. Micropore spherical silica gel and water are selected as the working pair. A gravity heat pipe with methanol as working medium is designed to output the cooling. Experimental investigations have indicated that under typical air conditioning conditions, for the first prototype, a cooling capacity of 687W and a COP (coefficient of performance) of 0.307 can be obtained. However, for the improved one, a cooling capacity of 790W and a COP of 0.446 can be reached. It is also proved that the operating temperatures have strong influences on the performance. The designed room air conditioner can be driven by a low grade heat source (<90{sup o}C) and has small dimensions of 300mm (depth), 500mm (width) and 950mm (height). (author)

  6. 冰蓄冷空调系统的设计及分析和测算%On design and analysis for ice storage air-conditioner system and its measurement

    Institute of Scientific and Technical Information of China (English)

    宋智军

    2012-01-01

    Taking the ice storage air-conditioner system at A5 Block Office Building along Jinrong Street in Beijing as the example, the paper provides the loading balance strategies for the ice storage air-conditioner system, according to the features of the ice storage technology, the allo- cation main machine and ice storage equipment, undertakes the reasonable measurement for its operation cost, and proves the installation capaci- ty of the ice storage system is 65% of the regular air-conditioner system and its operation cost takes up 53% of the regulation air-conditioner cooling system.%以北京金融街A5地块写字楼的冰蓄冷空调系统工程为例,根据冰蓄冷技术的特点,配置主机和蓄冰设备,给出了冰蓄冷系统的负荷平衡策略,并对其运行费用进行合理测算,表明冰蓄冷系统的装机容量是常规空调系统的65%,运行费用是常规空调制冷系统的53%。

  7. Feasibility analysis of solar air conditioner for buildings

    Energy Technology Data Exchange (ETDEWEB)

    Lian, Yongwang; Ma, Weibin [Chinese Academy of Sciences, Guangzhou (China). Guangzhou Inst. of Energy Conversion; Wu, Guoxiang [Guangzhou City Construction and Development Co. Ltd. (China)

    2008-07-01

    Technical and economic feasibility analysis on solar air conditioner for buildings is made in this paper, including the analysis of scientific and technological situation and development on solar air conditioner, the comparison on the technological characteristics among several styles of solar air conditioner, the analysis on the several ways of integration for solar air conditioners and buildings, energy consumption of domestic hot water, winter heating and summer air conditioner that supplied with fossil energy and solar energy are compared. A theoretical analysis on solar air conditioner driven by high temperature solar energy is presented. The conclusion is that the way of domestic hot water, winter heating and summer air conditioner for buildings supplied with one solar collector system is technical and economic feasible. (orig.)

  8. Strategy Guideline. HVAC Equipment Sizing

    Energy Technology Data Exchange (ETDEWEB)

    Burdick, Arlan [IBACOS, Inc., Pittsburgh, PA (United States)

    2012-02-01

    This guide describes the equipment selection of a split system air conditioner and furnace for an example house in Chicago, IL as well as a heat pump system for an example house in Orlando, FL. The required heating and cooling load information for the two example houses was developed in the Department of Energy Building America Strategy Guideline: Accurate Heating and Cooling Load Calculations.

  9. 75 FR 14368 - Energy Conservation Standards for Residential Central Air Conditioners and Heat Pumps: Public...

    Science.gov (United States)

    2010-03-25

    ... and heat pumps; the analytical framework, models, and tools that DOE is using to evaluate amended... Heat Pumps, EERE-2008-BT- STD-0006, 1000 Independence Avenue, SW., Washington, DC 20585-0121. Telephone... industrial equipment, including residential central air conditioners and heat pumps. (42 U.S.C. 6292(3)) In...

  10. Improved Modeling of Residential Air Conditioners and Heat Pumps for Energy Calculations

    Energy Technology Data Exchange (ETDEWEB)

    Cutler, D. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Winkler, J. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Kruis, N. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Christensen, C. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Brandemuehl, M. [Univ. of Colorado, Boulder, CO (United States)

    2013-01-01

    This report presents improved air conditioner and heat pump modeling methods in the context of whole-building simulation tools, with the goal of enabling more accurate evaluation of cost-effective equipment upgrade opportunities and efficiency improvements in residential buildings.

  11. An assessment of energy benefits of efficient household air-conditioners in Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Balbino Cardoso, R.; Horta Nogueira, L.A.; Palhares de Souza, E.; Haddad, J. [EXCEN Centro de Excelencia em Eficiencia Energetica, Universidade Federal de Itajuba-UNIFEI, Av. BPS 1303, CEP 37.500-903, Itajuba, Minas Gerais (Brazil)

    2012-08-15

    Increasing efficiency of electrical equipment is essential to national energy rationality, enabling energy consumption reduction and postponing inversion in distribution, transmission and generation, as well as mitigating environmental impacts associated with such activities. Considering such purposes, two actions have been promoted in Brazil: (a) minimum energy performance standards (MEPS) have been required for some appliances and (b) consumers have been informed about the most efficient products by 'endorsement labeling'. The purpose of this study is to assess window and split air-conditioners with Brazilian MEPS. To evaluate the impact of efficient air-conditioners in this market, a model was developed based on estimates for quantity of equipment in operation and unitary consumption, as determined by local temperature records. From this model, it was deduced that using only efficient conditioners (class A for Brazilian Labeling Program/INMETRO, with PROCEL Label) an annual saving of 322 GWh and a reduction in demand of 109 MW could be obtained in 2007. Furthermore, it was observed that the current MEPS established by Brazilian legislation for air-conditioners may be considered relatively low. Considering that MEPS are similar to those observed in China (the main exporter of air-conditioners to the Brazil), an energy saving of roughly 222 GWh could be achieved in the same year. Impacts on emission of greenhouse gases are also estimated.

  12. Experimental Study of Energy-Saving Air-Conditioner with Hot Water

    Institute of Scientific and Technical Information of China (English)

    CHEN Jian-bo; CHEN Dan; LU Ying

    2009-01-01

    Energy-saving air-conditioner with hot water is an air source heat pump air-conditioner,which can also supply hot water.The hot water is heated by a double pipe condenser connected with an air-cooled condenser in series in the system.This experiment of the energy-saving air-conditioner was carried out in the enthalpy-dif-ference air-conditioner laboratory.The hot water temperature and the compressor'S discharge and suction pres.sure were recorded in the working condition,where the ambient temperature was at 43℃,35℃,21℃,7℃,and 2℃separately.The results showed that the system operated stably and reliably. This system can supply 240 L hot water at 50℃in the whole year,and its coefficience of performance(COP)is much higher than the conventional air source heat pump system.Its energy conservation WaS proved by comparing the thermal effi.ciency with other sourece water heaters.

  13. Energy reduction of building air-conditioner with phase change material in Thailand

    Directory of Open Access Journals (Sweden)

    Nattaporn Chaiyat

    2014-11-01

    Full Text Available In this study, a concept of using phase change material (PCM for improving cooling efficiency of an air-conditioner had been presented under Thai climate. Paraffin waxes melting point at around 20 °C was selected to evaluate the thermal performance by reducing the air temperature entering the evaporating coil. The model of PCM celluloid balls had been performed with the air-conditioner. Moreover, the mathematical model of the air-conditioner with the PCM storage was developed and verified with the testing results. From the study results, it could be seen that the simulated data agreed quite well with the experimental result at the discrepant around 2–4%. Finally, the model was used to analyze the economic result which was found that the electrical consumption of the modified air-conditioner could be decreased 3.09 kW h/d. The electrical power consumption of the modified unit was 36.27 kW h/d at the operating time 15 h/d compared with 39.36 kW h/d of the normal unit at the operating time 12 h/d. The saving cost of the PCM bed could be 9.10% or 170.03 USD and the payback period was 4.15 y.

  14. Technical and economic analysis of energy efficiency of Chinese room air conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Fridley, David G.; Rosenquist, Gregory; Jiang, Lin; Li, Aixian; Xin, Dingguo; Cheng, Jianhong

    2001-02-01

    China has experienced tremendous growth in the production and sales of room air conditioners over the last decade. Although minimum room air conditioner energy efficiency standards have been in effect since 1989, no efforts were made during most of the 1990's to update the standard to be more reflective of current market conditions. In 1999, China's State Bureau of Technical Supervision (SBTS) included in their annual plan the development and revision of the 1989 room air conditioner standard, and experts from SBTS worked together with LBNL to analyze the new standards. Based on the engineering and life cycle-cost analyses performed, the most predominant type of room air conditioner in the Chinese market (split-type with a cooling capacity between 2500 and 4500 W (8500 Btu/h and 15,300Btu/h)) can have its efficiency increased cost-effectively to an energy efficiency ratio (EER) of 2.92 W/W (9.9 Btu/hr/W). If an EER standard of 2.92 W/W became effective in 2001, Chinese consumers would be estimated to save over 3.5 billion Yuan (420 million U.S. dollars) over the period of 2001-2020. Carbon emissions over the same period would be reduced by approximately 12 million metric tonnes.

  15. Low GWP Refrigerants Modelling Study for a Room Air Conditioner Having Microchannel Heat Exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Bo [ORNL; Bhandari, Mahabir S [ORNL

    2016-01-01

    Microchannel heat exchangers (MHX) have found great successes in residential and commercial air conditioning applications, being compact heat exchangers, to reduce refrigerant charge and material cost. This investigation aims to extend the application of MHXs in split, room air conditioners (RAC), per fundamental heat exchanger and system modelling. For this paper, microchannel condenser and evaporator models were developed, using a segment-to-segment modelling approach. The microchannel heat exchanger models were integrated to a system design model. The system model is able to predict the performance indices, such as cooling capacity, efficiency, sensible heat ratio, etc. Using the calibrated system and heat exchanger models, we evaluated numerous low GWP (global warming potential) refrigerants. The predicted system performance indices, e.g. cooling efficiency, compressor discharge temperature, and required compressor displacement volume etc., are compared. Suitable replacements for R22 and R-410A for the room air conditioner application are recommended.

  16. Alternatives to HCFC-22 for air conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Devotta, S. [Council of Scientific and Industrial Research, National Chemical Lab., Pune (India); Waghmare, A.V.; Domkundwar, B.M. [College of Engineering, Pune (India); Sawant, N.N. [National Inst. of Standards and Technology, Gaithersburg, MD (United States)

    2001-04-01

    Some selected fluids have been assessed for their suitability as alternatives to HCFC-22 for air conditioners. Only those refrigerants with zero ozone depletion potential are considered. NIST CYCLE{sub D} has been used for the comparative thermodynamic analysis. Among the refrigerants studied (HFC-134a, HC-290, R-407C, R-410A, and three blends of HFC-32, HFC-134a and HFC-125), HFC-134a offers the highest COP, but its capacity is the lowest and requires much larger compressors. The characteristics of HC-290 are very close to those of HCFC-22, and compressors require very little modification. Therefore, HC-290 is a potential candidate provided the risk concerns are mitigated as had been accomplished for refrigerators. For retrofitting, R-407C is probably the best candidate. (Author)

  17. Experimental study on split air conditioner with new hybrid equiment of energy storage and water heater all year round

    Energy Technology Data Exchange (ETDEWEB)

    Shaowei Wang; Zhenyan Liu [Shanghai Jiao Tong Univ. (China). School of Mechanical and Power Engineering; Yuan Li; Keke Zhao; Zhigang Wang [Qingdao Hisense Group Co. Ltd. (China)

    2005-11-01

    This paper presents a split air conditioner with a new hybrid equipment of energy storage and water heater all year round (ACWES). The authors made a special design on the storage tank to adjust the refrigerant capacity in the storage coils under different functions, instead of adding an accumulator to the system. An ACWES prototype, rebuilt from an original split air conditioner, has been finished, and experimental study of the operation processes of the prototype was done from which some important conclusions and suggestions have been made, which were helpful in the primary design and improvement of an ACWES system for potential users. (author)

  18. Improving Air-Conditioner and Heat Pump Modeling (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Winkler, J.

    2012-03-01

    A new approach to modeling residential air conditioners and heat pumps allows users to model systems by specifying only the more readily-available SEER/EER/HSPF-type metrics. Manufacturer data was used to generate full sets of model inputs for over 450 heat pumps and air conditioners. A sensitivity analysis identified which inputs can be safely defaulted 'behind-the-scenes' without negatively impacting the reliability of energy simulations.

  19. Improving Air-Conditioner and Heat Pump Modeling

    Energy Technology Data Exchange (ETDEWEB)

    Winkler, Jon [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2012-03-02

    This presentation describes a new approach to modeling residential air conditioners and heat pumps, which allows users to model systems by specifying only the more readily-available SEER/EER/HSPF-type metrics. Manufacturer data was used to generate full sets of model inputs for over 450 heat pumps and air conditioners. A sensitivity analysis identified which inputs can be safely defaulted “behind-the-scenes” without negatively impacting the reliability of energy simulations.

  20. Pulmonary functions in air conditioner users

    Directory of Open Access Journals (Sweden)

    Sandip M Hulke

    2013-01-01

    Full Text Available Context: In the modern lifestyle, use of air conditioner (AC has become very common. Aims: The present study was planned to assess the effect of ACs on pulmonary functions in young healthy non-smoker adults. Settings and Design: This study was a cross-sectional observational study. Sixty-six young adults (40 males and 26 females using ACs were compared with 70 non-AC users (young adults, 40 males and 30 females. Materials and Methods: Pulmonary function test was done using medical international research (MIR Spirolab II during home visits. Statistical Analysis Used: GraphPad Prism 5 software was used for analysis. Unpaired t test was used for lung function parameter. Chi- square test was used for the comparison of respiratory symptoms. Results: The results showed significant decrease in forced vital capacity (FVC (P < 0.05, forced expiratory volume in 1 s (FEV1 (P < 0.05, FEV1 as percentage of FVC in % [FEV1 (%] (P < 0.05, peak expiratory flow rate in L/s (PEFR (P < 0.05, forced expiratory flow rate in L/s in 25% of FVC (FEF25% (P < 0.05, and maximum voluntary ventilation (MVV (P < 0.01. Frequency of respiratory symptoms was higher in AC users. Conclusions: The results are suggestive of predisposition of AC users toward respiratory disorders in the form of mild airflow obstruction.

  1. Information technology equipment cooling method

    Energy Technology Data Exchange (ETDEWEB)

    Schultz, Mark D.

    2015-10-20

    According to one embodiment, a system for removing heat from a rack of information technology equipment may include a sidecar indoor air to liquid heat exchanger that cools air utilized by the rack of information technology equipment to cool the rack of information technology equipment. The system may also include a liquid to liquid heat exchanger and an outdoor heat exchanger. The system may further include configurable pathways to connect and control fluid flow through the sidecar heat exchanger, the liquid to liquid heat exchanger, the rack of information technology equipment, and the outdoor heat exchanger based upon ambient temperature and/or ambient humidity to remove heat generated by the rack of information technology equipment.

  2. 太阳能辐射空调器的研究%On Solar Radiant Air-conditioner

    Institute of Scientific and Technical Information of China (English)

    周亚东; 王军

    2014-01-01

    The paper introduces a solar radiant air-conditioner [1], which supplies heating and cooling for an office hall in one of the colleges in Haikou, Hainan. The system of the solar radiant air-conditioner uses solar water cooler and capillary network. The composition of the system is presented, and the major energy-saving parts of the system and the energy-saving performance ratio of the conventional temperature difference in air conditioning are analyzed from the thermodynamic theory. After running half a year, the system achieved the effects of substantial energy saving and reducing the thermal pollution of the environ-ment from the test data of the indicators. The system has the advantages of low investment and high utiliza-tion rate of the equipments.%介绍一种太阳能辐射空调器[1],为海南省海口市某学院办公事务大厅提供制冷的案例。系统用太阳冷水器与毛细管网相结合,介绍了其系统组成,并用热力学理论分析了本系统各主要节能部分与常规温差空调的节能效能比。系统运行半年,从各项指标检测数据看,取得了大幅节约能源,减少了对环境热污染的效果。该系统初投资少,设备利用率高,对今后的推广有一定的指导作用。

  3. Information technology equipment cooling system

    Science.gov (United States)

    Schultz, Mark D.

    2014-06-10

    According to one embodiment, a system for removing heat from a rack of information technology equipment may include a sidecar indoor air to liquid heat exchanger that cools warm air generated by the rack of information technology equipment. The system may also include a liquid to liquid heat exchanger and an outdoor heat exchanger. The system may further include configurable pathways to connect and control fluid flow through the sidecar heat exchanger, the liquid to liquid heat exchanger, the rack of information technology equipment, and the outdoor heat exchanger based upon ambient temperature and/or ambient humidity to remove heat from the rack of information technology equipment.

  4. Estimation of heat rejection based on the air conditioner use time and its mitigation from buildings in Taipei City

    Energy Technology Data Exchange (ETDEWEB)

    Hsieh, Chun-Ming; Aramaki, Toshiya; Hanaki, Keisuke [The University of Tokyo, Bunkyo-ku, Tokyo (Japan). Department of Urban Engineering

    2007-09-15

    The main work in the research focuses on the analysis and mitigation of the anthropogenic heat discharged from buildings, which is one of the main reasons leading to the heat island effect. The residential and commercial buildings, divided into 10 categories, with HVAC systems were analyzed by the building energy program, EnergyPlus. With the help of GIS, the heat rejection of all the residential and commercial buildings in DaAn Ward of Taipei City were evaluated, in which the spatial data and diurnal variation of the heat rejection were described by 3-h time periods. Furthermore, the effect of mitigation strategies was discussed. The first strategy was to change the wall/roof material of building envelope. The second and third strategies, from the viewpoint of energy saving, were to change the temperature setting of air conditioners and to turn off the lighting and equipment when not in use. The fourth strategy was to use a better efficiency of the cooling systems. Finally, the evaluation of installing the water-cooled cooling system, which discharges heat in the form of sensible and latent heat, was also included. (author)

  5. Application of adhesives in bus air conditioner%胶粘剂在大巴空调上的应用

    Institute of Scientific and Technical Information of China (English)

    林文

    2013-01-01

    The bus air conditioner is the important equipment for improving the riding comfort and the requirement for bus air conditioner is more and more high.The sealing problems including the leakage of refrigerant,water or air have great impact on the performance of bus air conditioner,which are important factors for the quality of bus air conditioning.This paper analyzed the applications of adhesives and sealants in the bus air conditioner.%汽车空调是提高汽车乘坐舒适性的重要设备,对汽车空调的质量要求越来越高。汽车空调中对空调性能起到很大影响的密封问题如漏制冷剂、漏水、漏风等,都是关系到空调质量的重要因素。本文就大巴空调使用胶粘剂、密封胶的情况进行了分析。

  6. Performance Characteristics of Cross-Fin-Tube-Type Heat Exchanger for Air Conditioner

    Science.gov (United States)

    Sasaki, Naoe; Kakiyama, Shiro; Sanuki, Noriyoshi

    The effects of enhanced heat transfer tube with ability to control the heat transfer disturbance by mechanical tube expanding were experimentally investigated on the performance characteristics of air-cooled cross-fin-tube-type heat exchanger for air conditioner. Three kinds of the enhanced heat transfer tube were developed and used in the experiment. The enhanced heat transfer tube was a kind of spirally grooved tube and composed with the fins smaller than those of the conventional spirally grooved tube excepting four fins located in orthogonal position on the tube circumference. The optimum groove number to enhance the performance of heat exchanger was also shown.

  7. ATMOSPHERIC MOISTURE CONDENSATION TO WATER RECOVERY BY HOME AIR CONDITIONERS

    Directory of Open Access Journals (Sweden)

    Amir Hossein Mahvi

    2013-01-01

    Full Text Available Earth’s atmosphere contains billion cubic meters of fresh water, which is considerable as a reliable water resource, especially in sultry areas. What is important in this context, how to extract the water, in an economic manner. In order to extract water from air conditioner, no need to spend any cost, because water produced as a by-product and trouble production. This cross-sectional study was conducted to evaluate the quantity and chemical quality of water obtained from Bandar Abbas air conditioners; at intervals beginning of March to early December of 2010. Sixty six samples were taken in cluster random plan. Bandar Abbas divided into four clusters; based on distance to shore and population density. Chemical tests which included: Turbidity, alkalinity, total hardness, Dissolved Solids (TDS and Electrical Conductivity (EC and quantity measurement were performed on them. Obtained water had slightly acidic pH, near to neutral range. Total dissolved solids, electrical conductivity, total hardness and alkalinity of extracted water were in low rate. Each air conditioner produced 36 liter per day averagely. Split types obtained more water to window air conditioners. With regard to some assumptions, approximately 4680 to 9360 cubic meter per day water is obtainable which is suitable for many municipal and industrial water applications.

  8. Design of direct solar PV driven air conditioner

    KAUST Repository

    Huang, Bin-Juine

    2015-12-05

    © 2015 Elsevier Ltd. Solar air conditioning system directly driven by stand-alone solar PV is studied. The air conditioning system will suffer from loss of power if the solar PV power generation is not high enough. It requires a proper system design to match the power consumption of air conditioning system with a proper PV size. Six solar air conditioners with different sizes of PV panel and air conditioners were built and tested outdoors to experimentally investigate the running probabilities of air conditioning at various solar irradiations. It is shown that the instantaneous operation probability (OPB) and the runtime fraction (RF) of the air conditioner are mainly affected by the design parameter rpL (ratio of maximum PV power to load power). The measured OPB is found to be greater than 0.98 at instantaneous solar irradiation IT > 600 W m-2 if rpL > 1.71 RF approaches 1.0 (the air conditioner is run in 100% with solar power) at daily-total solar radiation higher than 13 MJ m-2 day-1, if rpL > 3.

  9. Development of vehicle magnetic air conditioner (VMAC) technology. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Gschneidner, Karl A., Jr.; Pecharsky, V.K.; Jiles, David; Zimm, Carl B.

    2001-08-28

    The objective of Phase I was to explore the feasibility of the development of a new solid state refrigeration technology - magnetic refrigeration - in order to reduce power consumption of a vehicle air conditioner by 30%. The feasibility study was performed at Iowa State University (ISU) together with Astronautics Corporation of America Technology Center (ACATC), Madison, WI, through a subcontract with ISU.

  10. Effect of air-conditioner exposure on semen quality

    Institute of Scientific and Technical Information of China (English)

    Min-LiLu; Jun-QingWu; Qiu-YingYang; Wei-JinZhou; Er-ShengGao

    2004-01-01

    Aim: To investigate the effect of air-conditioner exposure on semen quality. Methods: The data came from the healthy male volunteers, aged 22 to 30 years, who went to centers for maternity and children health for premarital physical examination in Shanghai,Henan, Zbejiang and Hebei from December 1998 to February 2000.

  11. Development of light-weight Al scroll compressor for car air conditioner

    Energy Technology Data Exchange (ETDEWEB)

    Park, I.; Park, Y. [Dept. of Metallurgical Engineering, Pusan National Univ., Pusan (Korea); Choi, I. [Dept. of Mechanical and Materials Engineering, Korea Maritime Univ., Pusan (Korea)

    2004-07-01

    The scroll compressor with high cooling efficiency and lower oscillating noise can be a candidate material for a part of car air conditioner, household air conditioner and so on. When Al alloy with high strength is used for scroll compressor instead of cast iron, rotation speed can be increased by weight reduction. To design Al alloy which has enough mechanical properties to replace cast iron, the effect of alloying elements, such as Si(13-15%), Cu(4-5%), and Mg(0.5-1%) and cooling rates on the mechanical properties of squeeze cast Al alloy was studied. The influence of Sr and P modification treatment on Si morphology was also studied. Aluminum alloy over 400MPa of tensile strength and 2% elongation was developed. Al scroll samples was fabricated by squeeze casting machine(UBE 800ton) with using 2 cavity mold. Flow-3D which is a three dimensional melt flow analysis program was used to find most proper mold design and optimum process conditions for squeeze casting before making samples. Relationship between secondary dendrite arm spacing and cooling rate was simulated by Flow-3D and compared with experimental results. (orig.)

  12. 房间空调器综合性能优化及应用研究%Room Air Conditioner Combination Performance Optimization and Applied Research

    Institute of Scientific and Technical Information of China (English)

    王平; 张士友; 董际鼎

    2014-01-01

    制冷量、制热量、能效比和噪声是房间空调器最重要的性能指标。通过对空调器的噪声控制和降低噪声方法进行研究,合理处理空调器噪声、节能与产品成本的关系;采用提高空调器配机系数和高传热系数的热交换器提升空调器能效系数和冷重比。从理论分析结合实际操作方法,介绍了在降低噪声和产品成本的同时,提高空调器产品能效比、冷重比、配机系数等性能优化方法,并取得较好效果。%There are many performance indexes for room air conditioner, such as cooling capacity, heating capacity, EER and noise. Through research on the method of noise control and reducing of air conditioner, the relationship with noise, energy conservation and product cost of air conditioner is managed rationally. In order to increase the energy efficiency coefficient and cooling-weight ratio of air conditioner, the heat exchangers which could increase matching coefficient and heat transfer coefficient of air conditioner are used. The method of theoretical analysis and practical operating experience is used. Meanwhile the performance optimization methods for increasing EER, cooling-weight ratio and matching coefficient of air conditioner are introduced with inducing noise and product cost which achieve better efficiency.

  13. Analysis on Technology and Economic Feasibility of Air Conditioner%天然气空调的技术经济分析

    Institute of Scientific and Technical Information of China (English)

    何于涛; 魏敦崧; 刘敏飞

    2001-01-01

    文章简述了天然气应用于空调机组的技术概况,通过办公室空调冷热源的四种方案比较,分析了以天然气为驱动能源的空调机组的经济性,此外文章还就以天然气为驱动能源的空调机组对环境的影响以及在小区集中供冷供热中的应用前景进行了讨论.%This article briefs on the technology of applying NG to air conditioner. with the comparison between 4proposals on cooling and warming resources for office air conditioner, the economic feasibility of NG as drivingenergy is analyzed. Furthermore, this article discusses the environmental impact of air conditioner using NG,

  14. Using Field-Metered Data to Quantify Annual Energy Use of Portable Air Conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Burke, Thomas [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Willem, Henry [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Ni, Chun Chun [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Stratton, Hannah [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Chen, Yuting [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Ganeshalingam, Mohan [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Iyer, Maithili [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Price, Sarah [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Dunham, Camilla [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2014-12-01

    As many regions of the United States experience rising temperatures, consumers have come to rely increasingly on cooling appliances (including portable air conditioners) to provide a comfortable indoor temperature. Home occupants sometimes use a portable air conditioner (PAC) to maintain a desired indoor temperature in a single room or enclosed space. Although PACs in residential use are few compared to centrally installed and room air conditioning (AC) units, the past few years have witnessed an increase of PACs use throughout the United States. There is, however, little information and few research projects focused on the energy consumption and performance of PACs, particularly studies that collect information from field applications of PACs. The operation and energy consumption of PACs may differ among geographic locations and households, because of variations in cooling load, frequency, duration of use, and other user-selected settings. In addition, the performance of building envelope (thermal mass and air leakage) as well as inter-zonal mixing within the building would substantially influence the ability to control and maintain desirable indoor thermal conditions. Lawrence Berkeley National Laboratory (LBNL) conducted an initial field-metering study aimed at increasing the knowledge and data related to PAC operation and energy consumption in the United States.

  15. Design AND Fabrication OF Homemade Air Conditioner

    Directory of Open Access Journals (Sweden)

    Naikodi Mallappa,

    2014-04-01

    Full Text Available Human always tries for better comfort and sophistication at each level of his life. Considering air conditioning, evaporative cooler are used in less humidity and dry climate. The limitation of evaporative cooler is that it is not suitable in humid environment and also their performance is poor in the places where ventilation is not proper. The objective of this project is to increase the effectiveness of the ordinary table fan by using simple mechanism and overcome the limitation of evaporative cooler. In this project the table fan is wound with copper tube by copper wire. Vinyl tube is connected with one end of the copper tube and another end of vinyl tube is connected with pump. Pump immersed in the cooling chamber. Vinyl tube is connected with another end of copper tube another end of vinyl tube is immersed in the cooling chamber. Fan and pump connected with electricity pump and is sucks the cool water from the cooling chamber.

  16. A Proposal for the Time Domain Modeling of Split Air Conditioners for Consumer Reimbursement Studies

    Science.gov (United States)

    Rezende, Paulo Henrique Oliveira; Almeida Junior, Afonso Bernardino; Gondim, Isaque Nogueira; Oliveira, José Carlos

    2015-04-01

    This paper deals with computer application procedures for the evaluation of the causal consistency between anomalous phenomena manifested in electrical networks, along with the physical damage associated with electrical equipment and possible reimbursement requests. The focus is on the development of an air conditioner appliance model of the type known as split founded upon a representation, in the time domain, in accordance with the Alternative Transients Program (ATP) simulator requirements. This approach permits investigations concerning the performance of the product when submitted to ideal and non-ideal supply conditions. Once the equipment model is implemented in the program, a set of investigative studies are carried out to show the device performance under specific energy quality disturbance conditions. In addition, there are still the results for the validation of the process established through the correlation between computational performance of the air conditioner with corresponding studies carried out experimentally, which are presented herein. Moreover, once the effectiveness of the developed model is verified, it is implemented into the Requests for Reimbursement Software. Investigations related to the correlation between disturbances and the levels of thermal and dielectric tolerance are then performed aiming at illustrating the use of the research results for the reimbursement analyzes purposes.

  17. Development and Analysis of Desiccant Enhanced Evaporative Air Conditioner Prototype

    Energy Technology Data Exchange (ETDEWEB)

    Kozubal, E.; Woods, J.; Judkoff, R.

    2012-04-01

    This report documents the design of a desiccant enhanced evaporative air conditioner (DEVAP AC) prototype and the testing to prove its performance. Previous numerical modeling and building energy simulations indicate a DEVAP AC can save significant energy compared to a conventional vapor compression AC (Kozubal et al. 2011). The purposes of this research were to build DEVAP prototypes, test them to validate the numerical model, and identify potential commercialization barriers.

  18. Effects of Air Conditioner Use on Real-World Fuel Economy

    Energy Technology Data Exchange (ETDEWEB)

    Huff, Shean P [ORNL; West, Brian H [ORNL; Thomas, John F [ORNL

    2013-01-01

    Vehicle data were acquired on-road and on a chassis dynamometer to assess fuel consumption under several steady cruise conditions and at idle. Data were gathered for various air conditioner (A/C) settings and with the A/C off and the windows open. Two vehicles were used in the comparisonstudy: a 2009 Ford Explorer and a 2009 Toyota Corolla. At steady speeds between 64.4 and 112.7 kph (40 and 70 mph), both vehicles consumed more fuel with the A/C on at maximum cooling load (compressor at 100% duty cycle) than when driving with the windows down. The Explorer maintained this trend beyond 112.7 kph (70 mph), while the Corolla fuel consumption with the windows down matched that of running the A/C at 120.7 kph (75 mph), and exceeded it at 128.7 kph (80 mph). The largest incremental fuel consumption rate penalty due to air conditioner use occurred was nearly constant with a weakslight trend of increasing consumption with increasing compressor (and vehicle) speed. Lower consumption is seenobserved at idle for both vehicles, likely due to the low compressor speed at this operating point

  19. Energy Impacts of Oversized Residential Air Conditioners -- Simulation Study of Retrofit Sequence Impacts

    Energy Technology Data Exchange (ETDEWEB)

    Booten, C. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Christensen, C. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Winkler, J. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2014-11-01

    This research addresses the question of what are the energy consequences for oversizing of an air conditioner in a home. Conventional wisdom holds that oversizing the AC results in significant energy penalties. However, the reason for this was shown to be due to crankcase heaters and not due to cycling performance of the AC, and is only valid for a particular set of assumptions. Adding or removing individual characteristics, such as ducts or crankcase heaters, can have measurable impacts on energy use. However, with all other home characteristics held constant, oversizing the AC generally has a small effect on cooling energy use, even if the cycling performance of the unit is poor. The relevant aspects of air conditioner modeling are discussed to illustrate the effects of the cycling loss coefficient, Cd, capacity, climate, ducts and parasitic losses such as crankcase heaters. A case study of a typical 1960's vintage home demonstrates results in the context of whole building simulations using EnergyPlus.

  20. 空调器运行性能影响因素简析%Analysis on the Long-term Performance of Air Conditioner Operation

    Institute of Scientific and Technical Information of China (English)

    夏建军; 戴兴学; 叶檀

    2013-01-01

    The effects of on-off controlled air conditioners, outdoor temperature and dust contaminate on the performance of air conditioner are carried out on the 3 different rated capacity air conditioners in the paper. The results show that the effects on the cooling capacity and energy efficiency ratio are not more than 4% and 5% by on-off controlled air conditioner, 10% and 15% by temperature, 12% and 16% by dust contaminate respectively. So the dust contaminate and temperature on the air conditioner are important factors on evaluating the air conditioner is compliance with the long-term energy saving.%  本文通过3种不同额定制冷量的热泵型房间空调器研究了开停机、室外温度以及粉尘污染等因素对空调器长期运行性能的影响规律。结果表明,开停机对空调器制冷能力的最大衰减率不超过4%,EER不超过5%,室外温度对空调器制冷能力的最大衰减率不超过10%,EER不超过15%,粉尘污染对空调器制冷能力的最大衰减率不超过12%,EER不超过16%。因此,在实际评价空调器是否满足长效节能要求时,需着重考虑粉尘污染和温度负荷两个因素对空调器长期运行性能的影响。

  1. 空调四通阀端孔及内平面加工专机研制%Development of a customized equipment suitable to ending hole and interior plane processing of four-way valve in air conditioner

    Institute of Scientific and Technical Information of China (English)

    吕晓天; 刘中华; 应申舜; 林绿高

    2013-01-01

    This paper presents the customized equipment suittable to ending hole and interior plane processing of four-way valves, the customized equipment intergrates processing functions including burnishing, broaching, automatic workpiece loding and unloading. The operating principle of four-way valves is firstly presented; Then, the broaching process and burnishing process are respectively analyzed, on this basis, the basic structure of the customized equipment that integrating burnishing and broaching process is designed. Its operating principle is then presented, take the foundation for example, designs method of the key components of the customized equipment is presented; In the end, the application of the equipment is prospected. Practical application shows that the customized equipment is reliable, has simple structure and high degree automatization. In addition, it ensures easy maintenances and cleanness, can effectively improve the productivity of four-way valve.%设计了一种新型的空调专用四通阀端孔及内平面加工的专用机床,该专用机床集成挤光与拉削的加工工艺,并实现自动上下料.首先,介绍了四通阀工作原理;然后,分析了四通阀挤光和拉削加工工艺特点,在此基础上,设计了该挤光拉削一体化加工专机的机械结构;接着分析了其工作原理,并以底座为例,介绍了关键零部件的设计方法;最后给出了应用研究.应用结果表明,该四通阀加工专机工作可靠,结构简单,自动化程度高,便于维修、调整,可有效提高劳动生产率.

  2. Life Cycle Assessment of Residential Heating and Cooling Systems in Minnesota A comprehensive analysis on life cycle greenhouse gas (GHG) emissions and cost-effectiveness of ground source heat pump (GSHP) systems compared to the conventional gas furnace and air conditioner system

    Science.gov (United States)

    Li, Mo

    Ground Source Heat Pump (GSHP) technologies for residential heating and cooling are often suggested as an effective means to curb energy consumption, reduce greenhouse gas (GHG) emissions and lower homeowners' heating and cooling costs. As such, numerous federal, state and utility-based incentives, most often in the forms of financial incentives, installation rebates, and loan programs, have been made available for these technologies. While GSHP technology for space heating and cooling is well understood, with widespread implementation across the U.S., research specific to the environmental and economic performance of these systems in cold climates, such as Minnesota, is limited. In this study, a comparative environmental life cycle assessment (LCA) is conducted of typical residential HVAC (Heating, Ventilation, and Air Conditioning) systems in Minnesota to investigate greenhouse gas (GHG) emissions for delivering 20 years of residential heating and cooling—maintaining indoor temperatures of 68°F (20°C) and 75°F (24°C) in Minnesota-specific heating and cooling seasons, respectively. Eight residential GSHP design scenarios (i.e. horizontal loop field, vertical loop field, high coefficient of performance, low coefficient of performance, hybrid natural gas heat back-up) and one conventional natural gas furnace and air conditioner system are assessed for GHG and life cycle economic costs. Life cycle GHG emissions were found to range between 1.09 × 105 kg CO2 eq. and 1.86 × 10 5 kg CO2 eq. Six of the eight GSHP technology scenarios had fewer carbon impacts than the conventional system. Only in cases of horizontal low-efficiency GSHP and hybrid, do results suggest increased GHGs. Life cycle costs and present value analyses suggest GSHP technologies can be cost competitive over their 20-year life, but that policy incentives may be required to reduce the high up-front capital costs of GSHPs and relatively long payback periods of more than 20 years. In addition

  3. Life-cycle cost and payback period analysis for commercial unitary air conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Rosenquist, Greg; Coughlin, Katie; Dale, Larry; McMahon, James; Meyers, Steve

    2004-03-31

    This report describes an analysis of the economic impacts of possible energy efficiency standards for commercial unitary air conditioners and heat pumps on individual customers in terms of two metrics: life-cycle cost (LCC) and payback period (PBP). For each of the two equipment classes considered, the 11.5 EER provides the largest mean LCC savings. The results show how the savings vary among customers facing different electricity prices and other conditions. At 11.5 EER, at least 80% of the users achieve a positive LCC savings. At 12.0 EER, the maximum efficiency analyzed, mean LCC savings are lower but still positive. For the {ge} $65,000 Btu/h to <135,000 Btu/h equipment class, 59% of users achieve a positive LCC savings. For the $135,000 Btu/h to <240,000 Btu/h equipment class, 91% of users achieve a positive LCC savings.

  4. Small fan assisted air conditioner for thermal comfort and energy saving in Thailand

    Energy Technology Data Exchange (ETDEWEB)

    Atthajariyakul, Surat; Lertsatittanakorn, Charoenporn [Faculty of Engineering, Mahasarakham University, Khamriang, Kantaravichai, Mahasarakham 44150 (Thailand)

    2008-10-15

    From the fact that Thai people have a tolerance to high air temperature and are accustomed to high air movement from electric fans in non-air conditioned space, this paper proposes the use of small fan assisted air conditioners for human thermal comfort and energy saving in Thailand. In the study, a total 15 students were tested in a 2.5 x 3.5 x 2.5 m{sup 3} test room equipped with a 12,000 Btu/h split type air conditioner. During the tests, the room air temperature was varied from 25, 26, 27 and 28{sup o}C every 1 h. A small fan with 15 cm diameter was placed in front of each subject. In each hour, the small fan was varied to supply a small area with velocity from 0.2, 0.5, 1, 1.5 and 2 m/s. In each condition, the subjects were asked to vote for their thermal sensation. The results showed that the temperature set point could be increased up to 28{sup o}C when a small fan was used to supply local air velocity from 0.5 to 2 m/s according to individual preference. This would reduce the electricity consumption of the air conditioning unit. According to the proposed method, this can save energy for office buildings in the commercial sector as high as 1959.51 GWh/year. (author)

  5. Performance assessment of HC-290 as a drop-in substitute to HCFC-22 in a window air conditioner

    Energy Technology Data Exchange (ETDEWEB)

    Devotta, S. [National Environmental Engineering Research Institute, Nagpur (India); Padalkar, A.S. [National Chemical Laboratory, Pune (India). Process Development Division; Sane, N.K. [Walchand College of Engineering, Sangli (India). Department of Mechanical Engineering

    2005-06-01

    As per the Montreal Protocol, CFCs and HCFCs are being phased out. HCFC-22 is used in window air conditioners. This paper presents the experimental performance study of a window air conditioner with propane (HC-290), a natural refrigerant, as a drop-in substitute to HCFC-22. Experimental results showed that HC-290 had 6.6% lower cooling capacity for the lower operating conditions and 9.7% lower for the higher operating conditions with respect to HCFC-22. The coefficient of performance for HC-290 was 7.9% higher for the lower operating conditions and 2.8% higher for the higher operating conditions. The energy consumption of the unit with HC-290 was lower in the range 12.4-13.5% than HCFC-22. The discharge pressures for HC-290 were lower in the range 13.7-18.2% than HCFC-22. For HC-290, the pressure drop was lower than HCFC-22 in both heat exchangers. This paper also presents simulation results for the heat exchangers of an HCFC-22 window air conditioner with HC-290 as a drop-in substitute. The simulation has been carried out using EVAP-COND, a heat exchanger model developed by NIST [National Institute of Standards and Technology. EVAP-COND: simulation models for finned-tube heat exchangers, Maryland, USA (2003). http://www2.bfrl.nist.gov/software/evap-cond/ [18

  6. Active Participation of Air Conditioners in Power System Frequency Control Considering Users’ Thermal Comfort

    Directory of Open Access Journals (Sweden)

    Rongxiang Zhang

    2015-09-01

    Full Text Available Air conditioners have great potential to participate in power system frequency control. This paper proposes a control strategy to facilitate the active participation of air conditioners. For each air conditioner, a decentralized control law is designed to adjust its temperature set point in response to the system frequency deviation. The decentralized control law accounts for the user’s thermal comfort that is evaluated by a fuzzy algorithm. The aggregation of air conditioners’ response is conducted by using the Monte Carlo simulation method. A structure preserving model is applied to the multi-bus power system, in which air conditioners are aggregated at certain load buses. An inner-outer iteration scheme is adopted to solve power system dynamics. An experiment is conducted on a test air conditioner to examine the performance of the proposed decentralized control law. Simulation results on a test power system verify the effectiveness of the proposed strategy for air conditioners participating in frequency control.

  7. Installation Specifications of Air-Conditioners for Household and Similar Purposes

    Institute of Scientific and Technical Information of China (English)

    Hu Zhiqiang

    2011-01-01

    Background An air-conditioner known as "30% quality and 70% installation",the quality of its installation is closely related to its service life and application effect.Although air-conditioner manufacturers attach high importance to installation,and there are often the installation requirements specified in the product manual or instructions for installation,there are still no unified,scientific and complete national standards and corresponding regulations for household air-conditioner,which results in the less standardized installation of air-conditioner and the unacceptable quality of installation,and also leaves a lot of hidden quality and safety problems.By means of extensive market survey and the after-sale information statistical analysis of air-conditioner,it is discovered that the nonstandard installation of air-conditioner may lead to the following problems and accidents.

  8. Research on a Micro-Grid Frequency Modulation Strategy Based on Optimal Utilization of Air Conditioners

    Directory of Open Access Journals (Sweden)

    Qingzhu Wan

    2016-12-01

    Full Text Available With the proportion of air conditioners increasing gradually, they can provide a certain amount of frequency-controlled reserves for a micro-grid. Optimizing utilization of air conditioners and considering load response characteristics and customer comfort, the frequency adjustment model is a quadratic function model between the trigger temperature of the air conditioner compressor, and frequency variation is provided, which can be used to regulate the trigger temperature of the air conditioner when the micro-grid frequency rises and falls. This frequency adjustment model combines a primary frequency modulation method and a secondary frequency modulation method of the energy storage system, in order to optimize the frequency of a micro-grid. The simulation results show that the frequency modulation strategy for air conditioners can effectively improve the frequency modulation ability of air conditioners and frequency modulation effects of a micro-grid in coordination with an energy storage system.

  9. Hardware-in-the-Loop Simulation of a Distribution System with Air Conditioners under Model Predictive Control: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Sparn, Bethany F [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Ruth, Mark F [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Krishnamurthy, Dheepak [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Pratt, Annabelle [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Lunacek, Monte S [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Jones, Wesley B [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-08-01

    Many have proposed that responsive load provided by distributed energy resources (DERs) and demand response (DR) are an option to provide flexibility to the grid and especially to distribution feeders. However, because responsive load involves a complex interplay between tariffs and DER and DR technologies, it is challenging to test and evaluate options without negatively impacting customers. This paper describes a hardware-in-the-loop (HIL) simulation system that has been developed to reduce the cost of evaluating the impact of advanced controllers (e.g., model predictive controllers) and technologies (e.g., responsive appliances). The HIL simulation system combines large-scale software simulation with a small set of representative building equipment hardware. It is used to perform HIL simulation of a distribution feeder and the loads on it under various tariff structures. In the reported HIL simulation, loads include many simulated air conditioners and one physical air conditioner. Independent model predictive controllers manage operations of all air conditioners under a time-of-use tariff. Results from this HIL simulation and a discussion of future development work of the system are presented.

  10. Progress towards Managing Residential Electricity Demand: Impacts of Standards and Labeling for Refrigerators and Air Conditioners in India

    Energy Technology Data Exchange (ETDEWEB)

    McNeil, Michael A.; Iyer, Maithili

    2009-05-30

    The development of Energy Efficiency Standards and Labeling (EES&L) began in earnest in India in 2001 with the Energy Conservation Act and the establishment of the Indian Bureau of Energy Efficiency (BEE). The first main residential appliance to be targeted was refrigerators, soon to be followed by room air conditioners. Both of these appliances are of critical importance to India's residential electricity demand. About 15percent of Indian households own a refrigerator, and sales total about 4 million per year, but are growing. At the same time, the Indian refrigerator market has seen a strong trend towards larger and more consumptive frost-free units. Room air conditioners in India have traditionally been sold to commercial sector customers, but an increasing number are going to the residential sector. Room air conditioner sales growth in India peaked in the last few years at 20percent per year. In this paper, we perform an engineering-based analysis using data specific to Indian appliances. We evaluate costs and benefits to residential and commercial sector consumers from increased equipment costs and utility bill savings. The analysis finds that, while the BEE scheme presents net benefits to consumers, there remain opportunities for efficiency improvement that would optimize consumer benefits, according to Life Cycle Cost analysis. Due to the large and growing market for refrigerators and air conditioners in India, we forecast large impacts from the standards and labeling program as scheduled. By 2030, this program, if fully implemented would reduce Indian residential electricity consumption by 55 TWh. Overall savings through 2030 totals 385 TWh. Finally, while efficiency levels have been set for several years for refrigerators, labels and MEPS for these products remain voluntary. We therefore consider the negative impact of this delay of implementation to energy and financial savings achievable by 2030.

  11. Performance of a solar liquid desiccant air conditioner - An experimental and theoretical approach

    Energy Technology Data Exchange (ETDEWEB)

    Alizadeh, Shahab [Queensland University of Technology, Faculty of Built Environment and Engineering, GPO Box 2434, Brisbane 4001 (Australia)

    2008-06-15

    In this paper the results of testing a solar liquid desiccant air conditioner (LDAC) in the tropical climate of Queensland, Australia have been presented. The system uses polymer plate heat exchanger (PPHE) for dehumidification/indirect evaporative cooling, and a cooling pad as the direct evaporative cooler for the dry air leaving the PPHE. Lithium chloride, which is an effective desiccant in air dehumidification, was used in the experiments and a scavenger air regenerator concentrates the dilute solution from the dehumidifier using hot water from flat plate solar collectors. The data obtained from performance monitoring of the solar LDAC operating on a commercial site in Brisbane was compared with a previously developed model for the PPHE. The comparison reveals that good agreement exists between the experiments and model predictions. The inaccuracies are well within the measuring errors of the temperature, humidity and the air and solution flow rates. The above tests further indicate a satisfactory performance of the unit by independently controlling the air temperature and humidity inside the conditioned space. In order to prevent carryover of the solution particles into the environment, eliminators are used at outlet of the absorber unit and the regenerator. An alternative method in preventing the carryover is the use of indirect cooling, in which the supply air does not contact the solution. The method can be used to produce potable water from the atmospheric air in remote areas. The liquid desiccant system can be used in the HVAC industry, either as a packaged roof-top air conditioner, or as an air handler unit for commercial applications. The system could also be used for space heating in winter due to the property of desiccants to provide heat when wetted. (author)

  12. Optimal Design of Automotive Thermoelectric Air Conditioner (TEAC)

    Science.gov (United States)

    Attar, Alaa; Lee, HoSung; Weera, Sean

    2014-06-01

    The present work is an analytical study of the optimal design of an automotive thermoelectric air conditioner (TEAC) using a new optimal design method with dimensional analysis that has been recently developed by our research group. The optimal design gives not only the optimal current but also the optimal geometry (i.e., the number of thermocouples, the geometric factor, or the hot fluid parameters). The optimal design for the TEAC is carried out with two configurations: air-to-liquid and air-to-air heat exchangers.

  13. Analysis of Eco friendly Refrigerants Usage in Air-Conditioner

    Directory of Open Access Journals (Sweden)

    C. Chinnaraj

    2011-01-01

    Full Text Available Problem statement: There are two types of global warming contributions through refrigeration and air conditioning systems. The first one is the Direct Global Warming Potential (DGWP due to the emission of refrigerants and their interaction with heat radiation. The second one is the Indirect Global Warming Potential (IDGWP due to the emission of Carbon Dioxide (CO2 by consuming the energy that is generated through the combustion of fossil fuels. Most of refrigerants used in vapor Compression system were Chlorofluorocarbon (CFCs and Hydro Chlorofluorocarbon (HCFCs which contains chlorine and if any leakage in the system, these gases will go up and reach stratosphere. The chlorine atoms in the gases will act as a catalyst to destroy ozone layer and cause ozone depletion which causes health hazards, global warming, melting of polar ice caps and drought. Hence, it is necessary to minimize the Global warming and Ozone depletion. The refrigerant R22 widely used in the air-conditioners is a major Contributor of Chlorofluorocarbons (CFCs which cause irreparable loss to the ozone layer and has to be replaced. Approach: To conserve the energy and minimize the global warming, the systems should be designed as more energy efficient and also to minimize Ozone depletion, the eco friendly refrigerants are to be selected and tested as alternative refrigerants to R22. Hence, a window air conditioner of 3.5 kW capacity fitted with Electronic Expansion Valve (EEV instead of capillary tube as an expansion device, was tested for its performance with the selected eco friendly refrigerants R407C and R290 as an alternative to R22 under fixed indoor and outdoor chamber temperatures in the experimental set up and varying the EEV opening. Results: It has been observed from the experimental studies that when the smaller capacity R22 window air conditioner with EEV is retrofitted with R407C and R290, compared to the performance given by R22, the Coefficient Of Performance

  14. Experimental investigation of a CO{sub 2} automotive air conditioner

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Hongsheng; Chen, Jiangping; Chen, Zhijiu [Institute of Refrigeration and Cryogenics Engineering, Shanghai Jiao Tong University, Shanghai 200030 (China)

    2005-12-01

    In this study, a CO{sub 2} automotive air conditioner prototype was designed and constructed. The compressor was of swash plate design; the gas cooler and evaporator were made of fin-tubes; a manual expansion valve and an internal heat exchanger accumulator were used. The lubricant, the CO{sub 2} charge, the evaporator outlet pressure, the compressor speed, the air inlet temperature and flow rate of the gas cooler and the air flow rate of the evaporator were varied and the performance of the prototype was experimentally investigated in detail. The cooling capacity, compressor power consumption, CO{sub 2} mass flow rate, and COP value were analyzed. The experimental results showed that the CO{sub 2} system performance was greatly affected by different lubricants; the CO{sub 2} system performance was sensitive to the mass charge; the high side pressure affected the system performance greatly and a high side pressure controller was needed. (author)

  15. Modeling of a split type air conditioner with integrated water heater

    Energy Technology Data Exchange (ETDEWEB)

    Techarungpaisan, P.; Theerakulpisut, S.; Priprem, S. [Mechanical Engineering Department, Faculty of Engineering, Khon Kaen University, 123 Mittrapab Rd., Muang, Khon Kaen 40002 (Thailand)

    2007-04-15

    This paper presents a steady state simulation model to predict the performance of a small split type air conditioner with integrated water heater. The mathematical model consists of submodels of system components such as evaporator, condenser, compressor, capillary tube, receiver and water heater. These submodels were built based on fundamental principles of heat transfer, thermodynamics, fluid mechanics, empirical relationships and manufacturer's data as necessary. The model was coded into a simulation program and used to predict system parameters of interest such as hot water temperature, condenser exit air temperature, evaporator exit air temperature, mass flow rate of refrigerant, heat rejection in the condenser and cooling capacity of the system. The simulation results were compared with experimental data obtained from an experimental rig built for validating the mathematical model. It was found that the experimental and simulation results are in good agreement. (author)

  16. Performance assessment of HCFC-22 window air conditioner retrofitted with R-407C

    Energy Technology Data Exchange (ETDEWEB)

    Devotta, S. [National Environmental Engineering Research Institute, Nehru Marg, Nagpur 440 020 (India); Padalkar, A.S. [Process Development Division, National Chemical Laboratory, Homi Bhabha Road, Pune 411 008 (India); Sane, N.K. [Department of Mechanical Engineering, Walchand College of Engineering, Sangli 416 415 (India)

    2005-12-01

    This paper presents the experimental performance analysis of a 1.5 TR window air-conditioner, retrofitted with R-407C, as a substitute to HCFC-22. Experimental results showed that R-407C, for the operating conditions covered in this study, had lower cooling capacity in the range 2.1-7.9% with respect to HCFC-22. The coefficient of performance for R-407C was lower in the range 7.9-13.5%. The power consumption of the unit with R-407C was higher in the range 6-7% than HCFC-22. The discharge pressures for R-407C were higher in the range 11-13% than HCFC-22. This paper also presents simulation results of heat exchangers of an HCFC-22 window air conditioner retrofitted with R-407C. The simulation has been carried out using EVAP-COND, a heat exchanger model developed by National Institute of Standards and Technology, U.S.A. The simulated evaporator capacities are within +/-3% of the experimentally measured cooling capacities for both refrigerants. Simulation results for R-407C and HCFC-22 are compared. The exit temperatures of R-407C are lower by 1.9{sup o}C to 5.2{sup o}C in the condenser and are higher by 3.2{sup o}C to 3.8{sup o}C in the evaporator than HCFC-22. Evaporating pressures of R-407C are higher by 4.5-5.3% as compared to HCFC-22. The pressure drops of R-407C are lower in both the evaporator and the condenser as compared to HCFC-22. The outlet temperatures of air for HCFC-22 and R-407C in both heat exchangers are nearly the same. (author)

  17. Cooling Shelf For Electronic Equipment

    Science.gov (United States)

    Tanzer, Herbert J.

    1989-01-01

    Heat-pipe action cools and maintains electronics at nearly constant temperature. System designed to control temperatures of spacecraft shelves or baseplates by combining honeycomb sandwich panel with reservoir of noncondensable gas and processing resulting device as variable-conductance heat pipe. Device provides flat surface for mounting heat-dissipating electronics that is effectively cooled and maintained at nearly constant temperature. Potentially useful in freeze drying, refrigeration, and air conditioning.

  18. Energy performance and consumption for biogas heat pump air conditioner

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Zhenjun [Architectural Engineering College, Qingdao Agricultural University, 266109 (China); Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, Qingdao 266101 (China); Tianjin University, Tianjin, 300072 (China); Wu, Huaizhi; Wu, Meiling [Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, Qingdao 266101 (China); Tianjin University, Tianjin, 300072 (China)

    2010-12-15

    Biogas engine-driven heat pump air conditioner is a new-style system which includes biogas engine-driven heat pump, primary heat exchanger, second heat exchanger, sprayed room and fans, pumps, etc. In summertime, the air can be reheated by the waste heat water from the biogas engine in the system, while the air can be reheated and humidified by the waste heat water in winter. Reducing or displacing electrical heating requirements can achieve the great opportunity for significant energy savings. This paper, therefore, aims to improve the energy performance of the AC system by using the waste heat from the biogas engine. The mathematic model was used to research the BHPAC. Explicitly, we investigated the influence of various factors including the outdoor air temperature and humidity in summer and winter. Results show that the biogas engine-driven heat pump air conditioner can save more energy than the electrical power heat pump. In summer, the minimum for percentage of primary energy saving for BHPAC is over 25%. With the outdoor air dry-bulb temperature and the relative humidity rises, the saving energy percentage rises. In winter, the minimum for percentage of primary energy saving for BHPAC is 37%. The more the outdoor air relative humidity of the outdoor air decreases, the more the BHPAC saves energy. It is proved that the system which is a highly actively fully utilizing energy technology has good partial load characteristic and good effects of energy saving. (author)

  19. Bacterial community structures in air conditioners installed in Japanese residential buildings.

    Science.gov (United States)

    Hatayama, Kouta; Oikawa, Yurika; Ito, Hiroyuki

    2017-08-16

    The bacterial community structures in four Japanese split-type air conditioners were analyzed using a next-generation sequencer. A variety of bacteria were detected in the air filter of an air conditioner installed on the first floor. In the evaporator of this air conditioner, bacteria belonging to the genus Methylobacterium, or the family of Sphingomonadaceae, were predominantly detected. On the other hand, the majority of bacteria detected in the air filters and evaporators of air conditioners installed on the fifth and twelfth floors belonged to the family Enterobacteriaceae. The source of bacteria belonging to the family Enterobacteriaceae may have been aerosols generated by toilet flushing in the buildings. Our results suggested the possibility that the bacterial contamination in the air conditioners was affected by the floor level on which they were installed. The air conditioner installed on the lower floor, near the ground, may have been contaminated by a variety of outdoor bacteria, whereas the air conditioners installed on floors more distant from the ground may have been less contaminated by outdoor bacteria. However, these suppositions may apply only to the specific split-type air conditioners that we analyzed, because our sample size was small.

  20. 16 CFR 305.12 - Labeling for central air conditioners, heat pumps, and furnaces.

    Science.gov (United States)

    2010-01-01

    ... pumps, and furnaces. (a) Layout. All energy labels for central air conditioners, heat pumps, and... air conditioners and heat pumps. (1) Headlines and texts, as illustrated in the prototype and sample.... (ii) Each heat pump label, except as noted in paragraph (g)(4)(iii) of this section, shall contain two...

  1. The Usage of Household Split-type Air Conditioner on Naval Vessel%家用分体式空调器在舰船上的使用情况

    Institute of Scientific and Technical Information of China (English)

    何磊; 施晓波

    2013-01-01

    This paper expatiates some problems of small-sized water-cooling air conditioners using on naval ships. It analyses advantages of household wind-cooling split-type air conditioners compared with marine small-sized air conditioners. Some key technologies on installing and using of household air conditioners on naval ships are pointed out. Through theoretical analysis and survey, it is thought to be practicable to use household split-type air conditioners on naval vessel.%  详细阐述了船用小型水冷式空调器在舰船使用存在的一些问题,分析当前家用分体式空调器相比船用小型空调器的优点,并指出家用空调在舰船安装使用的关键技术。通过理论分析及实船反复调研,认为舰船上采用家用分体式空调器是可行的。

  2. Investigation of the compressor part-load behaviour and its effects on the per annum energy consumption of the air conditioner; Untersuchung des Kompressor-Teillastverhaltens im Hinblick auf den Jahresverbrauch der Klimaanlage

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Klaus; Lechner, Bernhard [Virtual Vehicle. Kompetenzzentrum - Das virtuelle Fahrzeug Forschungsgesellschaft mbH (ViF), Graz (Austria); Rieberer, Rene [Technische Univ. Graz (Austria); Moenkediek, Thomas [Audi AG, Ingolstadt (Germany)

    2010-07-01

    The air conditioning system is one of the most important ancillary units of a motor vehicle. Energetic optimization of air conditioners has been a key issue of research at AUDI AG during the past few years. As a rule, the cooling capacity of the air conditioner is controlled by adapting the compressor lift if the compressor is driven by the car engine and control via the rotational speed is not possible. As air conditioners ted to be designed for extreme conditions, the compressor will work at part load in most operating conditions. Optimization of the energetic efficiency of the air conditioner also means to look at the part-load behaviour of the compressor. Simulations have been used successfully by AUDI AG for many years now; the have helped to shorten development times and improve the product quality. The contribution describes an advanced model of a swivel plate compressor of a R134a cooling cycle with particular consideration of part-lift operation. The simulation model is based on measurements with continous recording of the piston lift. The focus is on the influence of reduced lift on the compressor efficiency. Another point of interest is the successful integration of the compressor model in the overall refrigerating cycle model which will be used for simulations of system performance and efficiency and for further optimization of the air conditioner. (orig.)

  3. Analysis on Thermodynamic Perfectibility of Room Air Conditioners%房间空调器的热力学完善度分析

    Institute of Scientific and Technical Information of China (English)

    李晓凤; 马一太; 闫秋辉

    2013-01-01

    According to analysis on the energy efficiency standards of the constant speed room air conditioner and the variable speed type, differences between the two kinds of air conditioners exist in division standard, grades of energy efficiency and outdoor temperature starting refrigeration. Therefore, a survey was made about cooling capacity and EER as well as energy efficiency grades of the constant and variable speed room air conditioners. The thermodynamic perfectibility of the two types of room air conditioners was calculated for the performance evaluation. The calculation results show that energy efficiency standard of variable speed room air conditioners in 2008 is lower than that of constant room air conditioners. A new energy efficiency standard of the variable speed air conditioner is suggested in accordance with the consistent thermodynamic perfectibility.%  通过对定速与转速可控房间空调器能效标准的分析,发现两类房间空调器的能效划分标准、划分等级以及制冷运行室外温度发生时间均有不同的规定。因此对国内市场上的定速房间空调器制冷量和制冷循环的能效比(EER)、转速可控房间空调器制冷量和制冷季节能效比(SEER)、以及定速房间空调器与转速可控房间空调器的能效等级现状等方面进行了调研统计。利用热力学完善度对两类房间空调器能效等级进行计算,发现2008版转速可控房间空气调节器的能效等级的热力学完善度偏低,根据热力学完善度相一致的原则,提出转速可控房间空调器新的能效标准等级的建议。

  4. Evaluation of environmental and physiological factors of a whole ceiling-type air conditioner using a salivary biomarker

    Energy Technology Data Exchange (ETDEWEB)

    Tahara, Yusuke; Yamaguchi, Masaki [Graduate School of Engineering, Iwate University, 4-3-5 Ueda, Morioka 020-8551 (Japan); Morito, Naomi; Nishimiya, Hajime; Yamagishi, Hideyuki [Asahi Kasei Homes Corporation, R and D Laboratories, 2-1 Samejima, Fuji, Shizuoka 416-8501 (Japan)

    2009-06-15

    In order to improve environmental condition such as humidity and airflow in living spaces, a whole ceiling-type air conditioner is proposed. This novel air conditioner exhaust dispersed airflow from the whole ceiling by using a 3-dimensional knit fabric. The purpose of this paper is to reveal the effects when controlling humidity and airflow using the whole ceiling-type air conditioner compared to a commercialized concentrated exhaust air conditioner (normal-type air conditioner) under the same temperature. Salivary {alpha}-amylase activity (SAA) was used as an index of sympathetic nervous activity. An acute experiment for a 15 min period was conducted using 12 healthy young female adults. No significant differences in room and skin temperatures were observed between the whole ceiling-type air conditioner and the normal-type air conditioner. The whole ceiling-type air conditioner showed 11.1% lower humidity than the normal-type air conditioner. The whole ceiling-type air conditioner showed one-thirteenth the airflow of the normal-type air conditioner. As a result, the PMV of the whole ceiling-type air conditioner was more comfortable level than the normal one. Moreover, subjective evaluation questionnaire revealed a significant difference was observed in wind perception (windy). The SAA of subjects under the whole ceiling-type air conditioner showed significantly low values compared with the normal-type air conditioner. It was found that the subject's sympathetic nervous activity has been inactivated under the conditions of the whole ceiling-type air conditioner. Thus, it was revealed that the whole ceiling-type air conditioner provides a more comfortable air environment by reducing physical stimulations to humans. (author)

  5. Direct Liquid Cooling for Electronic Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Coles, Henry; Greenberg, Steve

    2014-03-01

    This report documents a demonstration of an electronic--equipment cooling system in the engineering prototype development stage that can be applied in data centers. The technology provides cooling by bringing a water--based cooling fluid into direct contact with high--heat--generating electronic components. This direct cooling system improves overall data center energy efficiency in three ways: High--heat--generating electronic components are more efficiently cooled directly using water, capturing a large portion of the total electronic equipment heat generated. This captured heat reduces the load on the less--efficient air--based data center room cooling systems. The combination contributes to the overall savings. The power consumption of the electronic equipment internal fans is significantly reduced when equipped with this cooling system. The temperature of the cooling water supplied to the direct cooling system can be much higher than that commonly provided by facility chilled water loops, and therefore can be produced with lower cooling infrastructure energy consumption and possibly compressor-free cooling. Providing opportunities for heat reuse is an additional benefit of this technology. The cooling system can be controlled to produce high return water temperatures while providing adequate component cooling. The demonstration was conducted in a data center located at Lawrence Berkeley National Laboratory in Berkeley, California. Thirty--eight servers equipped with the liquid cooling system and instrumented for energy measurements were placed in a single rack. Two unmodified servers of the same configuration, located in an adjacent rack, were used to provide a baseline. The demonstration characterized the fraction of heat removed by the direct cooling technology, quantified the energy savings for a number of cooling infrastructure scenarios, and provided information that could be used to investigate heat reuse opportunities. Thermal measurement data were used

  6. 并联冷却的太阳能复合式空调节能特性%Energy-saving Character of a Solar Hybrid Air Conditioner with Parallel Condensers

    Institute of Scientific and Technical Information of China (English)

    康靖; 王劲柏

    2015-01-01

    A hybrid solar air-conditioner with consideration of solar energy’s characteristics is proposed in this paper. We use the air conditioner models, which established by steady-state distribution parameters method, to simulate the influence of chilling water temperature obtained by solar assisted cooling system on the hybrid air conditioner operation performance. The air conditioner operation characteristics studied by analyzing the flow rate variation. Through comparison with another kind of basic model, we obtained variation of the thermal efficiency COP, and analyzed the energy saving character of this air conditioner simply.%根据太阳能的特点,提出了一种并联冷却的太阳能复合式空调器,并用稳态分布参数法建立空调器模型,来模拟计算太阳能辅助冷却系统制取的冷水水温变化对复合式空调器运行效果的影响。通过分析制冷剂流量变化研究该空调器的运行特性,并与另一种基本运行模式对比,得到了其热效能COP值的变化情况,并对该空调器的节能特性进行了简单的分析。

  7. Comparative Analysis of Fuzzy Inference Systems for Air Conditioner

    Directory of Open Access Journals (Sweden)

    Swati R. Chaudhari

    2014-12-01

    Full Text Available In today’s world there is exponential increase in the use of air conditioning devices. The enhancement in utilization of such devices makes it essential for them to work with their full capability and efficiency. The fuzzy inference systems are best suited for the applications requiring easy interpretation, human reasoning, accurate decision making and control. The fuzzy inference systems resemble human decision making and generate precise solutions from approximate information. A comprehensive review of fuzzy inference systems with weighted average and defuzzification is covered in this paper. The objective of the paper is to provide the comparative analysis of fuzzy inference systems. This paper is a quick reference for the researchers in studying the characteristics of fuzzy inference system in air conditioner.

  8. Mycoflora of air-conditioners dust from Riyadh, Saudi Arabia.

    Science.gov (United States)

    Bagy, M M; Gohar, Y M

    1988-01-01

    Using the hair baiting technique, 6 genera and 14 species were collected on Sabouraud's dextrose agar from 37 dust samples from air-conditioners. The most common fungi were Chrysosporium tropicum, C. indicum, C. keratinophilum, Aspergillus flavus followed by Acremonium strictum and Scopulariopsis brevicaulis. Using the dilution-plate method, 26 genera and 52 species were collected from 37 dust samples on glucose-(23 genera and 45 species) and cellulose-(18 genera and 34 species) Czapek's agar at 28 degrees C. The most prevalent species were Aspergillus niger, A. flavus, Penicillium chrysogenum, Stachybotrys chartarum, Ulocladium atrum, Mucor racemosus and Fusarium solani and A. niger, A. flavus, Trichoderma viride, P. chrysogenum, Ulocladium atrum, Chaetomium globosum, C. spirale, Stachybotrys chartarum and Mucor racemosus on the two media, respectively.

  9. 电子工业厂房洁净空调系统施工监理的控制要点%On controlling points for construction inspection for cleaning air-conditioner system of electronic industrial workshops

    Institute of Scientific and Technical Information of China (English)

    吕坤

    2015-01-01

    Combining with engineering cases,the paper analyzes the features of cleaning air-conditioner system of electronic industrial workshops, and illustrates the monitoring controlling points for the cleaning air-conditioner system of electronic industrial workshops from the materials and equipment entry,installation of air-conditioner wind system and air-conditioner water system,so as to enhance the cleaning air-conditioner system to achieve the expected effect.%结合工程案例,分析了电子工业洁净空调系统的特点,并从材料和设备进场、空调风系统安装、空调水系统安装三个方面出发,阐述了电子工业厂房洁净空调系统施工的监理控制要点,促使洁净空调系统达到预期的效果。

  10. Research and Evaluation for a Bed Air-conditioner by Semiconductor Thermoelectric Effect%一种利用半导体热电效应的空调床的性能研究及其评价

    Institute of Scientific and Technical Information of China (English)

    周敬雯; 邓帅; 代彦军; 王如竹

    2012-01-01

    为了降低夜间空调能耗,基于帕尔帖效应设计了一种床体局部空调,简称空调床.空调床由床头制冷装置和床尾供暖装置构成,在满足床内舒适温度需求的同时,可以实现“头凉脚暖”的局部温度场.测试结果表明:冬季空调床维持床内温度为22℃时,功率为0.1 kW~0.2kW,脚部空气温度比头部约高6℃;夏季当室温低于30℃,床内维持28℃时,功率为0.06kW至0.12kW,脚部空气温度比头部约高1.5℃.此外,通过系统模拟分析可知,一定条件下,空调床的使用可在冬季夜间节约空调耗电约52%,夏季节约42%.%In order to reduce energy consumption of air-conditioner during night, one zoning air-conditioner fixed on the bed, namely bed AC, is developed based on peltier effect. The bed AC is equipped with a heating unit on the foot part and a cooling unit on the head part. It not only meets the thermal comfort of a bed, but also can create a comfortable environment about "warm foot and cool head". In winter, bed AC can maintain bed air temperature at 22℃, and its power is about 0.1kW~0.2kW, and foot air temperature is approximately 6℃ higher than that of head. In summer, if room temperature is lower than 30 ℃, bed AC can keep bed air temperature at 28℃, and its power varies from 0.06kW to 0.12kW, and head air temperature is nearly 1.5℃ lower than that of foot. By system simulation, the energy-saving performance is also studied. It can be found that energy saving rate of bed AC in winter and summer sleeping time is 52% and 42% respectively, compared with traditional split air-conditioner.

  11. Keeping cool: use of air conditioning by australians with multiple sclerosis.

    Science.gov (United States)

    Summers, Michael P; Simmons, Rex D; Verikios, George

    2012-01-01

    Despite the known difficulties many people with MS have with high ambient temperatures, there are no reported studies of air conditioning use and MS. This study systematically examined air conditioner use by Australians with MS. A short survey was sent to all participants in the Australian MS Longitudinal Study cohort with a response rate of 76% (n = 2,385). Questions included hours of air-conditioner use, areas cooled, type and age of equipment, and the personal effects of overheating. Air conditioners were used by 81.9% of respondents, with an additional 9.6% who could not afford an air conditioner. Regional and seasonal variation in air conditioning use was reported, with a national annual mean of 1,557 hours running time. 90.7% reported negative effects from overheating including increased fatigue, an increase in other MS symptoms, reduced household and social activities, and reduced work capacity. Households that include people with MS spend between 4 and 12 times more on keeping cool than average Australian households.

  12. Simulation System of Modular Air Conditioner Control Based on WinCC%基于WinCC的模块式空调机控制仿真系统

    Institute of Scientific and Technical Information of China (English)

    尤志强

    2016-01-01

    本设计是仿真模块式空调机的控制系统,系统的基本工艺流程是:通过温度传感器对室内外的温度进行检测,设定温度与室内温度进行比较,确定空调加热还是制冷。利用四通阀、热交换器、压缩机进行温度调节。%This design is simulating modular air conditioner control system,the basic process of the system is: measure the temperature of exterior and interior used to text by the temperature sensor,setting a temperature compare with the interior temperature, then determine the air conditioner is heating or cooling, in the end adjust the temperature by four-way valves,switches,and compressors.

  13. Understanding Energy Impacts of Oversized Air Conditioners; NREL Highlights, Research & Development, NREL (National Renewable Energy Laboratory)

    Energy Technology Data Exchange (ETDEWEB)

    None

    2015-06-01

    This NREL highlight describes a simulation-based study that analyzes the energy impacts of oversized residential air conditioners. Researchers found that, if parasitic power losses are minimal, there is very little increase in energy use for oversizing an air conditioner. The research demonstrates that new residential air conditioners can be sized primarily based on comfort considerations, because capacity typically has minimal impact on energy efficiency. The results of this research can be useful for contractors and homeowners when choosing a new air conditioner or heat pump during retrofits of existing homes. If the selected unit has a crankcase heater, performing proper load calculations to be sure the new unit is not oversized will help avoid excessive energy use.

  14. Design and performance prediction of a novel zeolite-water adsorption air conditioner

    Energy Technology Data Exchange (ETDEWEB)

    Wang, D.C. [Institute of Refrigeration and Cryogenics, School of Mechanical and Power Energy Engineering, Shanghai Jiao Tong University, 1954, Huashan Road, Shanghai 200030 (China); Xia, Z.Z. [Institute of Refrigeration and Cryogenics, School of Mechanical and Power Energy Engineering, Shanghai Jiao Tong University, 1954, Huashan Road, Shanghai 200030 (China); Wu, J.Y. [Institute of Refrigeration and Cryogenics, School of Mechanical and Power Energy Engineering, Shanghai Jiao Tong University, 1954, Huashan Road, Shanghai 200030 (China)]. E-mail: jywu@sjtu.edu.cn

    2006-03-15

    A novel adsorption air conditioner is designed that supplies 8-12 deg. C chilled water for the fan coil in the locomotive operator cabin. Different from other two-bed adsorption cooling systems, this system has two adsorption/desorption chambers. One adsorber, one condenser and one evaporator are housed in one and the same adsorption/desorption chamber. There are no valves installed in the vacuum side. So, the reliability of the system is improved greatly. This machine uses zeolite and water as the working pairs. This system is driven by 350-450 deg. C exhaust gas generated by the internal combustion engine of the locomotive. The designed refrigerating power and COP (coefficient of performance) are 5 kW and 0.25, respectively, according to the requirements for the refrigeration output in the locomotive operator cabin and the waste heat provided by the engine. In this paper, a model for this system is described, and the simulation results are discussed. The model is validated in principle by limited experimental data. According to the calculation results, the refrigerating power of the machine is up to 10 kW with gas inlet temperature of 450 deg. C and evaporating temperature of 6.5 deg. C. The adsorber can be heated from 97 deg. C to 423 deg. C or cooled from 423 deg. C to 97 deg. C in 1320 s. Therefore, the heat and mass transfer performance of the adsorber is improved greatly. A few experimental data prove these conclusions.

  15. Effect of heat recovery water heater system on the performance of residential split air conditioner using hydrocarbon refrigerant (HCR22)

    Science.gov (United States)

    Aziz, A.; Thalal; Amri, I.; Herisiswanto; Mainil, A. K.

    2017-09-01

    This This paper presents the performance of residential split air conditioner (RSAC) using hydrocarbon refrigerant (HCR22) as the effect on the use of heat recovery water heater system (HRWHS). In this study, RSAC was modified with addition of dummy condenser (trombone coil type) as heat recovery water heater system (HRWHS). This HRWHS is installed between a compressor and a condenser by absorbing a part of condenser waste heat. The results show that RSAC with HRWHS is adequate to generate hot water with the temperature range about 46.58˚C - 48.81˚C when compared to without HRWHS and the use of dummy condenser does not give significant effect to the split air conditioner performance. When the use of HRWHS, the refrigerant charge has increase about 19.05%, the compressor power consumption has slightly increase about 1.42% where cooling capacity almost the same with slightly different about 0.39%. The condenser heat rejection is lower about 2.68% and the COP has slightly increased about 1.05% when compared to without HRWHS. The use of HRWHS provide free hot water, it means there is energy saving for heating water without negative impact to the system performance of RSAC.

  16. 7 CFR 58.222 - Dry dairy product cooling equipment.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Dry dairy product cooling equipment. 58.222 Section 58... DAIRY PRODUCTS 1 General Specifications for Dairy Plants Approved for USDA Inspection and Grading Service 1 Equipment and Utensils § 58.222 Dry dairy product cooling equipment. Cooling equipment shall...

  17. Thermoeconomic optimization of small size central air conditioner

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, G.Q.; Wang, L.; Liu, L.; Wang, Z. [Hunan University (China). College of Civil Engineering

    2004-03-01

    The application of thermoeconomic optimization design in an air-conditioning system is important in achieving economical life cycle cost. Previous work on thermoeconomic optimization mainly focused on directly calculating exergy input into the system. However, it is usually difficult to do so because of the uncertainty of input power of fan on the air side of the heat-exchanger and that of pump in the system. This paper introduces a new concept that exergy input into the system can be substituted for the sum of exergy destruction and exergy output from the system according to conservation of exergy. Although it is also difficult for a large-scale system to calculate exergy destruction, it is feasible to do so for a small-scale system, for instance, villa air conditioner (VAC). In order to perform thermoeconomic optimization, a program is firstly developed to evaluate the thermodynamic property of HFC 134a on the basis of Martin-Hou state equation. Authors develop thermodynamic and thermoeconomic objective functions based on second law and thermoeconomic analysis of VAC system. Two optimization results are obtained. The design of VAC only aimed at decreasing the energy consumption is not comprehensive. Life cycle cost at thermoeconomic optimization is lower than that at thermodynamic optimization. (author)

  18. Dirty air conditioners: Energy implications of coil fouling

    Energy Technology Data Exchange (ETDEWEB)

    Siegel, Jeffrey; Walker, Iain; Sherman, Max

    2002-03-01

    Residential air conditioning is responsible for a substantial amount of peak electrical demand and energy consumption throughout most of the United States. Coil fouling, the deposition of indoor dusts and other particulate matter on evaporator heat exchangers, increases system pressure drop and, correspondingly, decreases system air flow and air conditioner performance. In this paper, we apply experimental and simulation results describing particle deposition on evaporator coils as well as research about indoor particle and dust concentrations to determine coil fouling rates. The results suggest that typical coils foul enough to double evaporator pressure drop in about 7.5 years, much sooner than the expected 15-30 year life time for an evaporator coil. The most important parameters in determining coil fouling times are the efficiency of the filter and indoor particle concentrations, although filter bypass and duct and coil design are important as well. The reduced air flows that result from coil fouling cause typical efficiency and capacity degradations of less than 5%, however they can be much greater for marginal systems or extreme conditions. These energy issues, as well as possible indoor air quality issues resulting from fouling by biological aerosols, suggest that regular coil cleaning to ameliorate low flow and the elimination of filter bypass should be an important part of residential air conditioning commissioning and maintenance practices.

  19. Performance characteristics of a turbo expander substituted for expansion valve on air-conditioner

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Soo-Yong [Department of Mechanical and Aerospace Engineering (ReCAPT), Gyeongsang National University, 900 Gajoa-dong, Jinju 660-701 (Korea); Cho, Chong-Hyun [School of Mechanical and Aerospace Engineering, Gyeongsang National University, 900 Gajoa-dong, Jinju 660-701 (Korea); Kim, Chaesil [Department of Mechanical Engineering, Changwon National University, 9 Sarim-dong, Changwon 641-773 (Korea)

    2008-09-15

    An experimental study is conducted on a small turbo expander which could be applied to the expansion process in place of expansion valves in refrigerator or air-conditioner to improve the cycle efficiency by recovering energy from the throttling process. The operating gas is HFC134a and the maximum cooling capacity of experiment apparatus is 32.7 kW. Four different turbo expanders are tested to find the performance characteristics of the turbo expander when they operate at a low partial admission rate. The partial admission rate is 1.70% or 2.37, and expanders are operated in the supersonic flow. In the experiment, pressure and temperature are measured at 10 different locations in the experimental apparatus. In addition to these measurements, output power at the turbo expander is measured through a generator installed on a rotor shaft with the rotational speed. Performance data of the turbo expander are obtained at many part load operations by adjusting the output power of the generator. A maximum of 15.8% total-to-static efficiency is obtained when the pressure ratio and the partial admission ratio are 2.37 and 1.70%, respectively. Experimental results show that the optimal velocity ratio decreases when the pressure ratio is decreased, and peak efficiencies, which are obtained at locally maximized efficiency depending on the operating condition, vary linearly against the subcooling temperature or the pressure ratio. (author)

  20. Using Field-Metered Data to Quantify Annual Energy Use of Portable Air Conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Burke, Thomas [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Dept., Environmental Energy Technologies Division; Willem, Henry [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Dept., Environmental Energy Technologies Division; Ni, Chun Chun [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Dept., Environmental Energy Technologies Division; Stratton, Hannah [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Dept., Environmental Energy Technologies Division; Chen, Yuting [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Dept., Environmental Energy Technologies Division; Ganeshalingam, Mohan [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Dept., Environmental Energy Technologies Division; Iyer, Maithili [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Dept., Environmental Energy Technologies Division; Price, Sarah [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Dept., Environmental Energy Technologies Division; Dunham, Camilla [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Dept., Environmental Energy Technologies Division

    2014-12-12

    As many regions of the United States experience rising temperatures, consumers have come to rely increasingly on cooling appliances (including portable air conditioners) to provide a comfortable indoor temperature. Home occupants sometimes use a portable air conditioner (PAC) to maintain a desired indoor temperature in a single room or enclosed space. Although PACs in residential use are few compared to centrally installed and room air conditioning (AC) units, the past few years have witnessed an increase of PACs use throughout the United States. There is, however, little information and few research projects focused on the energy consumption and performance of PACs, particularly studies that collect information from field applications of PACs. The operation and energy consumption of PACs may differ among geographic locations and households, because of variations in cooling load, frequency, duration of use, and other user-selected settings. In addition, the performance of building envelope (thermal mass and air leakage) as well as inter-zonal mixing within the building would substantially influence the ability to control and maintain desirable indoor thermal conditions. Lawrence Berkeley National Laboratory (LBNL) conducted an initial field-metering study aimed at increasing the knowledge and data related to PAC operation and energy consumption in the United States. LBNL performed its field-metering study from mid-April to late October 2014. The study, which monitored 19 sites in the Northeastern United States (4 in upstate New York and 15 near Philadelphia), collected real-time data on PAC energy consumption along with information regarding housing characteristics, consumer behavior, and environmental conditions that were expected to affect PAC performance. Given the limited number of test sites, this study was not intended to be statistically representative of PAC users in the United States but rather to understand the system response to the cooling demand and to

  1. Evaluation of Alternative Refrigerants for Mini-Split Air Conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Abdelaziz, Omar [ORNL; Shrestha, Som S [ORNL

    2017-01-01

    The phase-out of hydrochlorofluorocarbons (HCFC) refrigerants in developing countries is currently underway according to the Montreal Protocol. R-22 is one of the most commonly used HCFCs in the developing nations. It is extremely well suited for air conditioning and refrigeration (AC&R) in high ambient temperature environments. Non-Article 5 countries have already gone through the phase-out of HCFCs and settled on using R-410A as the refrigerant of choice for AC applications. Previous studies have shown that R-410A results in significant capacity and performance degradation at higher ambient temperature conditions. As such, there is a growing concern on finding alternative refrigerants to R-22 that would have zero ODP, lower GWP, and at the same time maintain acceptable performance at higher ambient temperatures. Furthermore, the developed world s transition through higher global warming potential (GWP) refrigerants like HFC and HFC blends resulted in significant direct CO2 equivalent emissions. It is imperative to develop a bridge for developing nations to avoid the transition from HCFC to HFC and then from HFC to alternative lower GWP refrigerants. This paper summarizes data from an experimental campaign on alternative refrigerant evaluation for R-22 and R-410A substitutes for mini-split air conditioners designed for high ambient environments. The experimental evaluation was performed according to ANSI/ASHRAE Standard 37 and the performance was rated at test conditions specified by ANSI/AHRI 210-240 and ISO 5151. Additional tests were conducted at outdoor ambient temperatures of 52 C (125.6 F) and 55 C (131 F) to evaluate their performance at high ambient conditions. Alternative refrigerants, some of which are proprietary, included R-444B, DR-3, N-20b, ARM-20b, R-290, and DR-93 as alternatives to R-22 and R-32, DR-55, L41-2, ARM-71A, and HPR-2A as alternatives to R-410A. The units performances were first verified using the baseline refrigerant and then drop

  2. An Application of Green Quality Function Deployment to Designing an Air Conditioner

    Directory of Open Access Journals (Sweden)

    Peetam Kumar Dehariya

    2015-07-01

    Full Text Available The paper tackles a systematic and operational approach to Green Quality Function Deployment (GQFD, a customer oriented survey based quality management system with regular improvement in product development. GQFD shows balance between product development and environmental protection. GQFD is not used to determine their attributes and their levels. GQFD captures what product developers “think” would best satisfy customer needs considering Environmental factor. This research used Air Conditioner as a case study for implementation of GQFD. In the design of a new Air Conditioner, apply GQFD to find out the most important parameter and functions from customer point of view and then find out Technical Characteristics. These important parameters are then put into house of quality and make relation matrix between voice of customer and Technical Characteristics. From the result of QFD applied to Air Conditioner are short out the parameter which are require modification according to voice of customer and the result has used for new design.

  3. On scheme design for central air-conditioner project in some wholesale market of Urumchi%乌鲁木齐某批发市场中央空调工程方案设计

    Institute of Scientific and Technical Information of China (English)

    杜维; 朱辉

    2012-01-01

    Taking the central air-conditioner system of some clothes wholesale market in Urumchi as the research object,the paper introduces the design scheme,the design ideas of the central air-conditioner in the project,indicates the main design parameter and the air-conditioner loading and the main equipment,and sums up the problems and solutions in the operation of the air-conditioners,so it achieves better operation effect.%以乌鲁木齐某服装批发市场中央空调系统为研究对象,介绍了该工程中央空调设计方案及设计思路,并将主要设计参数及空调负荷、主要设备加以说明,最后总结了空调运行中遇到的问题及解决办法,取得了良好的运行效果。

  4. Development of a metal hydride refrigeration system as an exhaust gas-driven automobile air conditioner

    Energy Technology Data Exchange (ETDEWEB)

    Qin, Feng; Chen, Jiangping; Chen, Zhijiu [Institute of Refrigeration and Cryogenics Engineering, Shanghai Jiaotong University, Shanghai 200030 (China); Lu, Manqi; Yang, Ke [Engineering Center, Institute of Metal Research, Chinese Academy of Sciences, Shenyang, Liaoning Province 110016 (China); Zhou, Yimin [Research Center, Zhejiang Yinlun Machinery Co. Ltd., Tiantai County, Zhejiang Province 317200 (China)

    2007-10-15

    Aiming at developing exhaust gas-driven automobile air conditioners, two types of systems varying in heat carriers were preliminarily designed. A new hydride pair LaNi{sub 4.61}Mn{sub 0.26}Al{sub 0.13}/La{sub 0.6}Y{sub 0.4}Ni{sub 4.8}Mn{sub 0.2} was developed working at 120-200 C/20-50 C/-10-0 C. P-C isotherms and reaction kinetics were tested. Reaction enthalpy, entropy and theoretical cycling coefficient of performance (COP) were deducted from Van't-Hoff diagram. Test results showed that the hydride pair has flat plateau slopes, fast reaction dynamics and small hystereses; the reaction enthalpy of the refrigeration hydride is -27.1 kJ/mol H{sub 2} and system theoretical COP is 0.711. Mean particle sizes during cycles were verified to be an intrinsic property affected by constitution, heat treatment and cycle numbers rather than initial grain sizes. Based on this work pair, cylindrical reactors were designed and a function proving metal hydride intermittent refrigeration system was constructed with heat conducting oil as heat source and water as heat sink. The reactor equivalent thermal conductivity is merely 1.3 W/(m K), which still has not meet practical requirement. Intermittent refrigeration cycles were achieved and the average cooling power is 84.6 W at 150 C/30 C/0 C with COP being 0.26. The regulations of cycling performance and minimum refrigeration temperature (MRT) were determined by altering heat source temperature. Results showed that cooling power and system COP increase while MRT decreases with the growth of heat source temperature. This study develops a new hydride pair and confirms its application in automobile refrigeration systems, while their heat transfer properties still need to be improved for better performance. (author)

  5. Performance Optimization of Alternative Lower Global Warming Potential Refrigerants in Mini-Split Room Air Conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Bo [ORNL; Abdelaziz, Omar [ORNL; Shrestha, Som S [ORNL

    2017-01-01

    Oak Ridge National laboratory (ORNL) recently conducted extensive laboratory, drop-in investigations for lower Global Warming Potential (GWP) refrigerants to replace R-22 and R-410A. ORNL studied propane, DR-3, ARM-20B, N-20B and R-444B as lower GWP refrigerant replacement for R-22 in a mini-split room air conditioner (RAC) originally designed for R-22; and, R-32, DR-55, ARM-71A, and L41-2, in a mini-split RAC designed for R-410A. We obtained laboratory testing results with very good energy balance and nominal measurement uncertainty. Drop-in studies are not enough to judge the overall performance of the alternative refrigerants since their thermodynamic and transport properties might favor different heat exchanger configurations, e.g. cross-flow, counter flow, etc. This study compares optimized performances of individual refrigerants using a physics-based system model tools. The DOE/ORNL Heat Pump Design Model (HPDM) was used to model the mini-split RACs by inputting detailed heat exchangers geometries, compressor displacement and efficiencies as well as other relevant system components. The RAC models were calibrated against the lab data for each individual refrigerant. The calibrated models were then used to conduct a design optimization for the cooling performance by varying the compressor displacement to match the required capacity, and changing the number of circuits, refrigerant flow direction, tube diameters, air flow rates in the condenser and evaporator at 100% and 50% cooling capacities. This paper compares the optimized performance results for all alternative refrigerants and highlights best candidates for R-22 and R-410A replacement.

  6. Prospect of Gas Air-conditioners Development%燃气空调器的发展前景

    Institute of Scientific and Technical Information of China (English)

    金佳宾; 焦文玲

    2000-01-01

    分析了燃气空调器的发展前景,提出了推广使用燃气空调器的途径。%In the paper, the wide prospect of gas air-conditioners development are analyzed, the way to popularize and use of gas air-conditioners are proposed.

  7. XP CEN/TS 14825 (June 2004). Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling. Testing and rating at part load conditions; XP CEN/TS 14825 Juin 2004 Climatiseurs, groupes refroidisseurs de liquide et pompes a chaleur avec compresseur entraine par moteur electrique pour le chauffage et la refrigeration. Essais et determination des caracteristiques a charge partielle

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-06-01

    This technical specification covers the tests of air conditioners, heat pumps and liquid chillers in partial load conditions. It specifies the terms and definitions, the testing methods, the test report and the calculation method when the power reduction is due to the cyclic operation of the apparatus or to a power reduction of the compressor(s). The power reductions linked with the temperatures or with the system are excluded. (J.S.)

  8. Study on Energy Efficiency Decay of on-duty Room Air Conditioners%在用房间空气调节器能效衰减研究

    Institute of Scientific and Technical Information of China (English)

    何曙; 袁雅青; 吴志东; 田波; 戴兴学

    2015-01-01

    53 sets of on-duty room air conditioners coming from different temperature areas, made from different manufactures, having different cooling capacities and having been used no less than 5 years were tested and ana-lyzed.Results show that except for the decay rate of energy efficiency of products with different brands various signifi-cantly, the effect of service temperature areas, on-duty duration and cooling capacity on the decay rate of energy ef-ficiency is negligible.The energy efficiency of domestic air conditioners served for more than 5 years is much less than the minimum allowable energy efficiency values stipulated in current standards with majority 20%~30%lower, some even 54%lower.In order to analyze the potential of energy conservation and carbon dioxide reduction caused by accel-erating eliminating the on-duty domestic air conditioners, the market share of on-duty air conditioners in China in 2008 was taken for case study.Results indicate that even if the on-duty air conditioners were replaced by new air con-ditioners of minimum allowable energy efficiency, it will save 214.7 billion kWh power and reduce carbon dioxide e-mission 214.7 million ton every cooling season.If they are replaced by higher energy efficiency air conditioners or vari-able-speed ones, the potential of energy conservation and carbon dioxide reduction will be bigger.%对53台来自在不同温区、不同品牌的、不同制冷量、使用了5年及以上的在用房间空气调节器能效进行了测试分析,结果表明除不同品牌的产品能效衰减率差异较大外,使用温区、使用年限、产品制冷量对空调能效衰减率的影响不大。使用了5年或更长时间的家用空调器能效水平远低于当前标准规定的能效限定值,普遍低20%~30%,最高可低54%。为分析加速淘汰在用空调器的节能减排潜力,以2008年中国在用空调器的保有量进行估算,即使以当前最低能效水平的空调器进行

  9. 16 CFR Appendix I to Part 305 - Heating Performance and Cost for Central Air Conditioners

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Heating Performance and Cost for Central Air Conditioners I Appendix I to Part 305 Commercial Practices FEDERAL TRADE COMMISSION REGULATIONS UNDER SPECIFIC... Manufacturer's rated heating capacity (Btu's/hr.) Range of HSPF's Low High Single Package Units Heat Pumps...

  10. Variable Frequency Air Conditioner is Expected to Become Mainstream Product in Rural Market

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    <正>If it can be argued that in 2011 the rural market played a crucial role in the development of air conditioner industry,judging from the present growth trend,in the 2012 refrigeration year the rural market will play an even more important

  11. Product lifetime, energy efficiency and climate change: A case study of air conditioners in Japan.

    Science.gov (United States)

    Nishijima, Daisuke

    2016-10-01

    This study proposed a modelling technique for estimating life-cycle CO2 emissions of durable goods by considering changes in product lifetime and energy efficiency. The stock and flow of durable goods was modelled by Weibull lifetime distributions and the trend in annual energy efficiency (i.e., annual electricity consumption) of an "average" durable good was formulated as a reverse logistic curve including a technologically critical value (i.e., limit energy efficiency) with respect to time. I found that when the average product lifetime is reduced, there is a trade-off between the reduction in emissions during product use (use phase), due to the additional purchases of new, more energy-efficient air conditioners, and the increase in emissions arising from the additional production of new air conditioners stimulated by the reduction of the average product lifetime. A scenario analysis focused on residential air conditioners in Japan during 1972-2013 showed that for a reduction of average lifetime of 1 year, if the air conditioner energy efficiency limit can be improved by 1.4% from the estimated current efficiency level, then CO2 emissions can be reduced by approximately the same amount as for an extension of average product lifetime of 1 year.

  12. The Oklahoma Field Test: Air-conditioning electricity savings from standard energy conservation measures, radiant barriers, and high-efficiency window air conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Ternes, M.P.; Levins, W.P.

    1992-08-01

    A field test Involving 104 houses was performed in Tulsa, Oklahoma, to measure the air-conditioning electricity consumption of low-income houses equipped with window air conditioners, the reduction in this electricity consumption attributed to the installation of energy conservation measures (ECMS) as typically installed under the Oklahoma Weatherization Assistance Program (WAP), and the reduction achieved by the replacement of low-efficiency window air conditioners with high-efficiency units and the installation of attic radiant barriers. Air-conditioning electricity consumption and indoor temperature were monitored weekly during the pre-weatherization period (June to September 1988) and post-weatherization period (May to September 1989). House energy consumption models and regression analyses were used to normalize the air-conditioning electricity savings to average outdoor temperature conditions and the pre-weatherization indoor temperature of each house. The following conclusions were drawn from the study: (1) programs directed at reducing air-conditioning electricity consumption should be targeted at clients with high consumption to improve cost effectiveness; (2) replacing low-efficiency air conditioners with high-efficiency units should be considered an option in a weatherization program directed at reducing air-conditioning electricity consumption; (3) ECMs currently being installed under the Oklahoma WAP (chosen based on effectiveness at reducing space-heating energy consumption) should continue to be justified based on their space-heating energy savings potential only; and (4) attic radiant barriers should not be included in the Oklahoma WAP if alternatives with verified savings are available or until further testing demonstrates energy savings or other benefits in this typo of housing.

  13. Performance of a split-type air conditioner matched with coiled adiabatic capillary tubes using HCFC22 and HC290

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Guobing [School of Energy and Power Engineering, North China Electric Power University, Beijing 102206 (China); Zhang, Yufeng [School of Environmental Science and Engineering, Tianjin University, Tianjin 300072 (China)

    2010-05-15

    This paper experimentally investigated the system performance of a split-type air conditioner matching with different coiled adiabatic capillary tubes for HCFC22 and HC290. Experiments were carried out in a room-type calorimeter. The results have shown that (1) similar cooling effects can be achieved by matching various capillary tubes of different inner diameters; (2) parallel capillary tubes presented better system performance and flow stability with weaker inlet pressure fluctuations than the single capillary tube; (3) with the coil diameter of the capillary tube increasing from 40 mm to 120 mm, the mass flow rate tended to increase slightly. But the cooling capacity, input power and energy efficiency ratio (EER) did not show evident tendency of change; (4) the refrigerant charge and mass flow rate for HC290 were only 44% and 47% of that for HCFC22, respectively, due to the much lower density. And HC290 had 4.7-6.7% lower cooling capacity and 12.1-12.3% lower input power with respect to HCFC22. However, the EER of HC290 can be 8.5% higher than that of HCFC22, which exhibits the advantage of using HC290. In addition, the experimental uncertainties were analyzed and some application concerns of HC290 were discussed. (author)

  14. LDDX: A High Efficiency Air Conditioner for DOD Buildings

    Science.gov (United States)

    2017-02-01

    cooling market . 7.1.2 Solving Building Humidity Problems Despite the preceding simplified analysis showing that a very large segment of the HVAC market ...this demonstration is to show that comfortable indoor conditions can be maintained in a large segment of DOD’s installations with a significant...unlikely that any cooling technology that provides an enhanced latent capacity will successfully compete in this broad segment of the comfort

  15. The Oklahoma Field Test: Air-Conditioning Electricity Savings from Standard Energy Conservation Measures, Radiant Barriers, and High-Efficiency Window Air Conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Ternes, M.P.

    1992-01-01

    A field test involving 104 houses was performed in Tulsa, Oklahoma, to measure the air-conditioning electricity consumption of low-income houses equipped with window air conditioners, the reduction in this electricity consumption attributed to the installation of energy conservation measures (ECMs) as typically installed under the Oklahoma Weatherization Assistance Program (WAP), and the reduction achieved by the replacement of low-efficiency window air conditioners with high-efficiency units and the installation of attic radiant barriers. Air-conditioning electricity consumption and indoor temperature were monitored weekly during the pre-weatherization period (June to September 1988) and post-weatherization period (May to September 1989). House energy consumption models and regression analyses were used to normalize the air-conditioning electricity savings to average outdoor temperature conditions and the pre-weatherization indoor temperature of each house. The average measured pre-weatherization air-conditioning electricity consumption was 1664 kWh/year ($119/year). Ten percent of the houses used less than 250 kWh/year, while another 10% used more than 3000 kWh/year. An average reduction in air-conditioning electricity consumption of 535 kWh/year ($38/year and 28% of pre-weatherization consumption) was obtained from replacement of one low-efficiency window air conditioner (EER less than 7.0) per house with a high-efficiency unit (EER greater than 9.0). For approximately the same cost, savings tripled to 1503 kWh/year ($107/year and 41% of pre-weatherization consumption) in those houses with initial air-conditioning electricity consumption greater than 2750 kWh/year. For these houses, replacement of a low-efficiency air conditioner with a high-efficiency unit was cost effective using the incremental cost of installing a new unit now rather than later; the average installation cost for these houses under a weatherization program was estimated to be $786. The

  16. Properties and Cycle Performance of Refrigerant Blends Operating Near and Above the Refrigerant Critical Point, Task 2: Air Conditioner System Study

    Energy Technology Data Exchange (ETDEWEB)

    Piotr A. Domanski; W. Vance Payne

    2002-10-31

    The main goal of this project was to investigate and compare the performance of an R410A air conditioner to that of an R22 air conditioner, with specific interest in performance at high ambient temperatures at which the condenser of the R410A system may be operating above the refrigerant's critical point. Part 1 of this project consisted of conducting comprehensive measurements of thermophysical for refrigerant R125 and refrigerant blends R410A and R507A and developing new equation of state formulations and mixture models for predicting thermophysical properties of HFC refrigerant blends. Part 2 of this project conducted performance measurements of split-system, 3-ton R22 and R410A residential air conditioners in the 80 to 135 F (27.8 to 57.2 C) outdoor temperature range and development of a system performance model. The performance data was used in preparing a beta version of EVAP-COND, a windows-based simulation package for predicting performance of finned-tube evaporators and condensers. The modeling portion of this project also included the formulation of a model for an air-conditioner equipped with a thermal expansion valve (TXV). Capacity and energy efficiency ratio (EER) were measured and compared. The R22 system's performance was measured over the outdoor ambient temperature range of 80 to 135 F (27.8 to 57.2 C). The same test range was planned for the R410A system. However, the compressor's safety system cut off the compressor at the 135.0 F (57.2 C) test temperature. The highest measurement on this system was at 130.0 F (54.4 C). Subsequently, a custom-manufactured R410A compressor with a disabled safety system and a more powerful motor was installed and performance was measured at outdoor temperatures up to 155.0 F (68.3 C). Both systems had similar capacity and EER performance at 82.0 F (27.8 C). The capacity and EER degradation of both systems were nearly linearly dependent with rising ambient outdoor ambient test temperatures. The

  17. INTEGRATED ENGINEERING - SERVICE TEST OF AIR CONDITIONERS, COMPACT VERTICAL, 60,000 BTU/HR, 60- AND 400-CYCLE.

    Science.gov (United States)

    A summary is presented of the engineering test of 60,000 Btu/hr compact vertical air conditioners. The purpose of the test was to determine conformance of the test items to required performance characteristics. (Author)

  18. Automotive absorption air conditioner utilizing solar and motor waste heat

    Science.gov (United States)

    Popinski, Z. (Inventor)

    1981-01-01

    In combination with the ground vehicles powered by a waste heat generating electric motor, a cooling system including a generator for driving off refrigerant vapor from a strong refrigerant absorbant solution is described. A solar collector, an air-cooled condenser connected with the generator for converting the refrigerant vapor to its liquid state, an air cooled evaporator connected with the condenser for returning the liquid refrigerant to its vapor state, and an absorber is connected to the generator and to the evaporator for dissolving the refrigerant vapor in the weak refrigerant absorbant solution, for providing a strong refrigerant solution. A pump is used to establish a pressurized flow of strong refrigerant absorbant solution from the absorber through the electric motor, and to the collector.

  19. Study on Variable Capacity Control Mechanism of Scroll Compressor for Automotive Air Conditioner

    Science.gov (United States)

    Hirano, Takahisa; Shigeoka, Tetsuo

    As for the automotive air conditioner, (1) to keep the automotive cabin temperature in a comfortable region, (2) to improve driving feeling, (3) to drive the air conditioning system economically through all seasons, are universally required. Recently, from these points, compressors with variable capacity control mechanism for automotive air conditioners have been remarkably requested. We have developed a scroll comoressor with variable capacity control mechanism. The capacity control mechanism, which changes the channel area of the bypass hole continuously, according to the suction gas pressure and the discharge gas pressure, has been developed. In this report, we describe the mechanism of variable capacity control and the performance simulation program that has been developed for the scroll compressor. Further, we describe the measuring results of cylinder pressure behavior, the results of energy loss analysis and the effect of comfort, drivability, power saving in the refrigerating cycle using the developed capacity control compressor.

  20. Techno-Economic Analysis of Indian Draft Standard Levels for RoomAir Conditioners

    Energy Technology Data Exchange (ETDEWEB)

    McNeil, Michael A.; Iyer, Maithili

    2007-03-01

    The Indian Bureau of Energy Efficiency (BEE) finalized its first set of efficiency standards and labels for room air conditioners in July of 2006. These regulations followed soon after the publication of levels for frost-free refrigerators in the same year. As in the case of refrigerators, the air conditioner program introduces Minimum Efficiency Performance Standards (MEPS) and comparative labels simultaneously, with levels for one to five stars. Also like the refrigerator program, BEE defined several successive program phases of increasing stringency. In support of BEE's refrigerator program, Lawrence Berkeley National Laboratory (LBNL) produced an analysis of national impacts of standards in collaboration with the Collaborative Labeling and Standards Program (CLASP). That analysis drew on LBNL's experience with standards programs in the United States, as well as many other countries. Subsequently, as part of the process for setting optimal levels for air conditioner regulations, CLASP commissioned LBNL to provide support to BEE in the form of a techno-economic evaluation of air conditioner efficiency technologies. This report describes the methodology and results of this techno-economic evaluation. The analysis consists of three components: (1) Cost effectiveness to consumers of efficiency technologies relative to current baseline. (2) Impacts on the current market from efficiency regulations. (3) National energy and financial impacts. The analysis relied on detailed and up-to-date technical data made available by BEE and industry representatives. Technical parameters were used in conjunction with knowledge about air conditioner use patterns in the residential and commercial sectors, and prevailing marginal electricity prices, in order to give an estimate of per-unit financial impacts. In addition, the overall impact of the program was evaluated by combining unit savings with market forecasts in order to yield national impacts. LBNL presented

  1. Transient modeling of an air conditioner with a rapid cycling compressor and multi-indoor units

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Wei-Jiang [Institute of Refrigeration and Cryogenics, Shanghai Jiaotong University, Shanghai 200240 (China); Zhang, Chun-Lu [College of Mechanical Engineering, Tongji University, 4800 Cao An Highway, Shanghai 201804 (China)

    2011-01-15

    Rapid cycling the compressor is an alternative of the variable speed compressor to modulate the capacity of refrigeration systems for the purpose of energy saving at part-load conditions. The multi-evaporator air conditioner combined with the rapid cycling compressor brings difficulties in control design because of the sophisticated system physics and dynamics. In this paper the transient model of a multi-split air conditioner with a digital scroll compressor is developed for predicting the system transients under performance modulations. The predicted cycling dynamics are in good agreement with the experimental data. Based on the validated model, the impact of compressor idle power and cycle period to the part load performance is discussed. (author)

  2. Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

    Directory of Open Access Journals (Sweden)

    CHENNUCHETTY CHINNARAJ,

    2010-09-01

    Full Text Available A window air conditioner of 3.5 K.W capacity fitted with expansion devices such as capillary tube, thermostatic expansion valve and Electronic expansion valve was tested for its coefficient of performance, power required and refrigeration effect with respect to the refrigerants R22 and R407C under different operating conditions .Initially evaporator temperature was maintained at 279 K and condenser temperature was varied and then the test was conducted again in the same window air conditioner with electronic expansion valve alone as expansion device and by varying the refrigerant super heat temperature at inlet to the compressor from 273K to 293K for the refrigerants R 22, R 407C and R 290 The performance of electronic expansion valve with eco friendly refrigerants shows a positive effect and enable the industry to favorably displace the R22 and other types of expansion devices.

  3. Transient modeling of an air conditioner with a rapid cycling compressor and multi-indoor units

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Weijiang [Institute of Refrigeration and Cryogenics, Shanghai Jiaotong University, Shanghai 200240 (China); Zhang Chunlu, E-mail: chunlu.zhang@carrier.utc.co [College of Mechanical Engineering, Tongji University, 4800 Cao An Highway, Shanghai 201804 (China)

    2011-01-15

    Rapid cycling the compressor is an alternative of the variable speed compressor to modulate the capacity of refrigeration systems for the purpose of energy saving at part-load conditions. The multi-evaporator air conditioner combined with the rapid cycling compressor brings difficulties in control design because of the sophisticated system physics and dynamics. In this paper the transient model of a multi-split air conditioner with a digital scroll compressor is developed for predicting the system transients under performance modulations. The predicted cycling dynamics are in good agreement with the experimental data. Based on the validated model, the impact of compressor idle power and cycle period to the part load performance is discussed.

  4. Experimental Study of the Controlling Characteristics of Inverter-Driven Multi-type Air Conditioner

    Institute of Scientific and Technical Information of China (English)

    金纪峰; 陈江平; 陈芝久

    2004-01-01

    The controlling algorithm was studied for the inverter-driven multi-type air conditioner using electronic expansion valve(EEV) in outdoor unit. The performance of inverter-driven air conditioner with two different units was investigated by varying the outdoor ambient temperature and compressor speed. Based on the test results, the effect of EEV opening on the indoor unit exit superheat was discussed. For the specified outdoor ambient temperature scope and the EEV opening, the superheats of indoor units decrease with the outdoor ambient temperature rising. Improper distribution of refrigerant into each indoor unit will causes excessive superheat difference between two indoor units. Suggestions were then given for the controlling of the superheat.

  5. Economical and environmental impact of room air conditioners energy labels in Malaysia

    Energy Technology Data Exchange (ETDEWEB)

    Mahlia, T.M.I.; Masjuki, H.H.; Choudhury, I.A.; Ghazali, N.N.N. [University of Malaya, Kuala Lumpur (Malaysia). Dept. of Mechanical Engineering

    2002-12-01

    The usage of residential electrical appliances for the last two decades has increased rapidly in Malaysia together with the increasing income per capita. Like other developing countries with hot and humid climates, Malaysia has been experiencing dramatic growth in the number of use of air conditioners, and the usage will be higher in the future. In order to reduce energy consumption in the residential sector, the Department of Electricity and Gas Supply considers implementing energy labels for room air conditioners sometime in the coming year. This study attempts to calculate the economical and environmental impact of implementing this program in Malaysia. The study found the savings has exceeded the investment cost and the program has reduced the emissions caused by burning fossil fuel. (author)

  6. 浅谈纺织空调节能设计%Discussion on Energy Saving Design of Textile Air-conditioner

    Institute of Scientific and Technical Information of China (English)

    谭兴霞; 贺晋; 李淑萍

    2012-01-01

    文章从纺织空调系统的设计角度,提出几种行之有效的节能措施,为纺织空调设计提供几种节能方案。%Several effective energy saving measures were put forward from the aspects of design of air-conditioner system, and several energy saving methods were provided for the design of air-conditioner.

  7. Comparative Research on Air Conditioner with Gas-injected Rotary Compressor through Injection Port on Blade

    OpenAIRE

    Xingru, Liu; Baolong, Wang; Wenxing, Shi

    2016-01-01

    Rotary compressors are widely utilized in air conditionders and heat pumps. However, when rotary compressors were applied in room air conditioners, VRFs and domestic water heaters, the systems will experience heavily degradation of the heating capacity and COP as the ambient temperature goes low. Aimed at these problems, considerable research has been carried out to raise a series of solutions, such as economizer technology, cascade-type vapor compression heat pump system and two stage coupli...

  8. Solar Application in Air Conditioner Field%太阳能在空调领域的应用

    Institute of Scientific and Technical Information of China (English)

    2012-01-01

    Firstly, the background of solar application in air conditioner field was introduced, in other words, century conundrum of energy crisis and environmental pollution gave birth to solar research and develop-ment of air conditioner. Secondly, from view of technology, the author review solar air conditionerindustry sta-tus in photothermal utilization and photovoltaic utilization. Thirdly, from view of human sustainable develop-ment and market demand, solar air conditioner application prospect was analyzed. Finally, combined with the solar energy and air conditioner industry technical development direction, the author analyze future development trend of solar air conditioner, and on this basis , the author put forward effective popularizing ways of solar air conditioner.%  本文介绍了太阳能在空调领域应用背景,从技术层面对太阳能空调的光热和光电利用现状进行了回顾和分析,并从人类可持续发展和市场需求角度对太阳能空调的应用前景做出分析。结合太阳能和空调行业的技术发展方向研究,分析了太阳能空调的未来发展趋势,并在此基础上提出太阳能空调推广的有效途径。

  9. China Energy Efficiency Round Robin Testing Results for Room Air Conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Nan; Fridley, David; Zheng, Nina; Pierrot, Andre

    2010-06-07

    consuming products has always been an important component of all countries energy strategies. As we all know, a very large amount of total energy consumption is due to energy consuming products and equipment, which account for about 50% of China's total energy consumption. However, the current average energy utilization efficiency of this sector is only about 60%, 10 percent lower than the international advanced level. Therefore, China's energy consuming products and equipment sector holds great energy-saving potential. On the other hand, the energy supplied to these products is mainly from fossil fuel combustion, a major source of greenhouse gas (GHG) emissions. Therefore, improving the energy efficiency and augmenting the market share of market-dominant energy consuming products is of significant importance to achieving China's energy saving and emission reduction target and is an effective means to deal with energy and environmental constraints and climate change issues. Main energy consuming products generally include widely-used home appliances, industrial equipment, office equipment, transportation vehicles, etc. China is one of the major manufacturers and exporters of energy end-using products such as air-conditioners, refrigerators, televisions, etc. Their overall energy efficiency is comparatively low and the products are poorly designed, leading to great energy-saving potential. For example, electricity consumption of air conditioners accounts for about 20% of China's total electricity consumption and 40% of the summer electricity peak load in large and medium cities. However, less than 5% of units sold in the domestic market in 2009 reached the standard's highly efficient level of grade 2 above. The electricity consumption of electric motors and their related drive systems accounts for about 60% of China's total electricity consumption; however, less than 2% of the domestic market share consists of energy-efficient electric motor

  10. 浅析可燃性冷媒空调的安全要求%Analysis on New Safety Requirements for Air Conditioner With Flammable Ignition Source

    Institute of Scientific and Technical Information of China (English)

    范建波; 陈信勇; 肖彪; 于丽

    2015-01-01

    The refrigerant of HCFCs will be phase-out and replaced gradually by environmental refrigerant which are flammable and explosible. At the same time, air conditioner are electrical equipment which contains a lot of live parts, it is easy to ignite flammable gases. This paper analyzes the protection of ignition source of the air conditioner with flammable refrigerant according to the standard. It provides the reference for related personnel.%目前空调行业有计划地进行逐步淘汰HCFCs制冷剂,取而代之的是具有可燃可爆特性的环保制冷剂.空调属于用电设备,含有大量的带电部件,容易点燃可燃性气体.本文结合空调安全标准,浅析可燃制冷剂空调点火源的防护要求,供相关人员参考.

  11. Stochastic cooling equipment at the ISR

    CERN Multimedia

    1983-01-01

    The photo shows (centre) an experimental set-up for stochastic cooling of vertical betatron oscillations, used at the ISR in the years before the ICE ring was built. Cooling times of about 30 min were obtained in the low intensity range (~0.3 A). To be noted the four 50 Ohm brass input/output connections with cooling fins, and the baking-out sheet around the cylinder. On the left one sees a clearing electrode box allowing the electrode current to be measured, and the pressure seen by the beam to be evaluated.

  12. Measure Guideline. Air Conditioner Diagnostics, Maintenance, and Replacement

    Energy Technology Data Exchange (ETDEWEB)

    Springer, David [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Dakin, Bill [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States)

    2013-03-01

    This guideline responds to the need for an efficient means of identifying, diagnosing, and repairing faults in air conditioning systems in existing homes that are undergoing energy upgrades. Inadequate airflow due to constricted ducts or undersized filters, improper refrigerant charge, and other system defects can be corrected at a fraction of the cost of equipment replacement and can yield significant savings. The guideline presents a two-step approach to diagnostics and repair.

  13. Measure Guideline: Air Conditioner Diagnostics, Maintenance, and Replacement

    Energy Technology Data Exchange (ETDEWEB)

    Springer, D.; Dakin, B.

    2013-03-01

    This guideline responds to the need for an efficient means of identifying, diagnosing, and repairing faults in air conditioning systems in existing homes that are undergoing energy upgrades. Inadequate airflow due to constricted ducts or undersized filters, improper refrigerant charge, and other system defects can be corrected at a fraction of the cost of equipment replacement and can yield significant savings. The guideline presents a two-step approach to diagnostics and repair.

  14. Auto-ignition of lubricating oil working at high pressures in a compressor for an air conditioner

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chul Jin; Choi, Hyo Hyun [Department of Mechanical Engineering, Sejong University, Seoul 143-747 (Korea, Republic of); Sohn, Chae Hoon, E-mail: chsohn@sejong.ac.kr [Department of Mechanical Engineering, Sejong University, Seoul 143-747 (Korea, Republic of)

    2011-01-15

    Auto-ignition of lubricating oil working in a compressor for an air conditioner is studied experimentally. The adopted lubricating oil is an unknown mixture with multi-components and known to have flash point temperature of 170 deg. C. First, its auto-ignition temperature is measured 365 deg. C at atmospheric pressure. The lubricating oil works under high-pressure condition up to 30 atm and it is heated and cooled down repeatedly. Accordingly, auto-ignition temperatures or flammable limits of lubricating oil are required at high pressures with respect to fire safety. Because there is not a standard test method for the purpose, a new ignition-test method is proposed in this study and thereby, auto-ignition temperatures are measured over the pressure range below 30 atm. The measured temperatures range from 215 deg. C to 255 deg. C and they strongly depend on pressure of gas mixture consisting of oil vapor, nitrogen, and oxygen. They are close to flash point temperature and the lubricating oil can be hazardous when it works for high-pressure operating condition and abundant air flows into a compressor.

  15. Incidence of polybrominated diphenyl ethers in central air conditioner filter dust from a new office building

    Energy Technology Data Exchange (ETDEWEB)

    Ni Honggang; Cao Shanping; Chang Wenjing [Shenzhen Key Laboratory of Circular Economy, Shenzhen Graduate School, Peking University, Shenzhen 518055 (China); Zeng Hui, E-mail: huizeng0608@gmail.com [Shenzhen Key Laboratory of Circular Economy, Shenzhen Graduate School, Peking University, Shenzhen 518055 (China); Department of Ecology, College of Urban and Environmental Sciences, Peking University, Beijing 100871 (China)

    2011-07-15

    This study examined polybrominated diphenyl ethers (PBDEs) in central air conditioner filter (CACF) dust from a new office building in Shenzhen, China. Human exposure to PBDE via dust inhalation and ingestion were also estimated. PBDEs level in CACF dust was lower than those in the other countries and regions. Approximately 0.671 pg/kg bw/day PM{sub 2.5} (Particulate Matter up to 2.5 {mu}m in size) bounded {Sigma}{sub 15}PBDEs can be inhaled deep into the lungs and 4.123 pg/kg bw/day PM{sub 10} (Particulate Matter up to 10 {mu}m in size) bounded {Sigma}{sub 15}PBDEs tend to be deposited in the upper parts of the respiratory system. The average total intake of {Sigma}{sub 15}PBDEs via dust inhalation and ingestion for adults reached {approx}141 pg/kg bw/day in this building. This value was far below the reference dose (RfD) recommended by United States Environmental Protection Agency. Human exposure to PBDEs via dust inhalation and ingestion in the new building is less than the old ones. - Highlights: > Human exposure to PBDEs via dust inhalation and ingestion in the new building is less than that in the old ones. > PBDE emissions from indoor sources can be expected to continue for a long time as the PBDE-containing products in offices were to be kept many years. > The household consumer products, especially computers, are the main sources of PBDEs in central air conditioner filter dust. > Further studies are needed to fully understand the emission mechanism of PBDE from indoor consumer products. - PBDEs in central air conditioner filter dust from a new building were investigated

  16. Girth welding system for vortex type refrigeration compressor of air conditioner

    Institute of Scientific and Technical Information of China (English)

    Liu Xiaowen; Ma Caixia; Yang Siqian; Hu Jisheng

    2006-01-01

    According to the requirements of welding process for vortex type compressor of air conditioner manufactured in product line, a special girth welding machine with PLC as control core was developed, which had both upright and 45 ° incline service positions. And some key technologies were researched, such as structural design of machine body, reliable conduction of rotary weldments and quality control of welding process and so on. The experimental results showed that this machine could satisfy the requirements of welding quality and girth welding technology, results also proved the machine was a high-efficiency and low-cost automatic welding device.

  17. Deaths Due to Accidental Air Conditioner Compressor Explosion: A Case Series.

    Science.gov (United States)

    Behera, Chittaranjan; Bodwal, Jatin; Sikary, Asit K; Chauhan, Mohit Singh; Bijarnia, Manjul

    2017-01-01

    In an air-conditioning system, the compressor is a large electric pump that pressurizes the refrigerant gas as part of the process of turning it back into a liquid. The explosion of an air conditioner (AC) compressor is an uncommon event, and immediate death resulted from the blast effect is not reported in forensic literature. We report three such cases in which young AC mechanics were killed on the spot due to compressor blast, while repairing the domestic split AC unit. The autopsy findings, the circumstances leading to the explosion of the compressor, are discussed in this study. © 2016 American Academy of Forensic Sciences.

  18. Select Components and Finish System Design of a Window Air Conditioner with Propane

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Bo [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Abdelaziz, Omar [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-05-01

    This report describes the technical targets for developing a high efficiency window air conditioner (WAC) using propane (R-290). The baseline unit selected for this activity is a GE R-410A WAC. We established collaboration with a Chinese rotary compressor manufacturer, to select an R-290 compressor. We first modelled and calibrated the WAC system model using R-410A. Next, we applied the calibrated system model to design the R-290 WAC, and decided the strategies to reduce the system charge below 260 grams and achieve the capacity and efficiency targets.

  19. Experimental Study of the Effects of the Cycle Characteristics on the Refrigerant-Induced Noise in System Air-Conditioner

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Weui Bong [Pusan National University, Busan (Korea, Republic of); Han, Hyung Suk; Mo, Jin Yong; Lee, Jae Kwon [Samsung Electronics, Suwon (Korea, Republic of)

    2007-07-15

    The main sources of the refrigerant-induced noise can be classified 2 types according to its characteristics. One is due to the cyclic characteristics such as quality, velocity of the refrigerant, pressure drop and mass flow rate. The other is due to the structural characteristics such as distributed path pipe layout, distributor and expansion device. In this paper, the effects of cycle characteristics on the noise of multi-type system air-conditioner are investigated experimentally. In the indoor unit of multi-type air-conditioner, the variation of noise is examined when the in-flowing and out-flowing refrigerant to the indoor unit are 2-phase state according to its cycle control. And several factors are recommended in order to reduce the refrigerant-induced noise of the air-conditioner.

  20. Analysis for SEER of variable speed room air conditioner in China. Paper no. IGEC-1-104

    Energy Technology Data Exchange (ETDEWEB)

    Yitai, M.; Shengchun, L.; Lirong, M. [Tianjin Univ., Thermal Energy Research Inst., Tianjin (China)]. E-mail: liushch@tju.edu.cn

    2005-07-01

    In this paper, the calculation method for seasonal energy efficiency ratio (SEER) given in Standard JRA4046-1999 is analyzed and further modified. Based on temperature zone map of U.S., Japan and China and detailed weather data of eight Chinese cities in last 30 years, regional seasonal energy efficiency ratio (RSEER) and energy saving percentage of variable speed room air conditioner are analyzed and compared with various geographical regions in China. It is concluded that RSEER presents the associated effect of season, climate and geography, and therefore should be taken as an evaluation standard for room air conditioner, especially variable speed room air conditioner. Experimental measurements are conducted in the analysis to investigate the effect of energy efficiency ratio (EER) on the improvement of energy saving percentage and SEER. (author)

  1. Study on Water Treatment Technology of Central Air Conditioner%中央空调水处理研究

    Institute of Scientific and Technical Information of China (English)

    黎代华

    2015-01-01

    随着国家提倡节能减排,空调系统的节能越发引起人们的重视。文章通过介绍南博中央空调水处理,分析中央空调水系统中存在的问题,通过中央空调水处理提高中央空调制冷效率,从而实现节能的效果。%Due to the advocation of “energy saving and emission reduction” of Chinese government,more and more people pay attention to air conditioners energy conservation. This article analyzes the problems of central air conditioner water system,and discovers that the central air conditioner refrigeration efficiency will be improved through water treatment technology, and plenty of energy will be saved.

  2. Automatic line of high speed air-conditioner wing of Model YKC-12 air-conditioner wing%YKC-12空调翅片高速冲压自动生产线

    Institute of Scientific and Technical Information of China (English)

    周富才

    2001-01-01

    Construction and action principle of automatic line of high speed punching production of Model YKC-12 air-conditioner wing have been introduced in details.%介绍了YKC-12空调翅片高速冲压自动生产线的结构及其动作原理。

  3. Analysis of the life cycle of a air-conditioner: results of the study; L'analyse du cycle de vie d'un climatiseur: resultats d'etude

    Energy Technology Data Exchange (ETDEWEB)

    Barnabe, F. [CETIM, Pole d' Activite QSE, 93 - Saint-Ouen (France)

    2003-11-01

    French manufacturers of thermal, air-conditioning and refrigerating equipments, in association with the French technical center of mechanical industries (CETIM) and with the technical center of aeraulic and thermal industries (CETIAT), have carried out a life cycle analysis of a split cassette-type air-conditioner in order to qualitatively evaluate its impact on the environment. This paper presents the results of this study: more than 90% of the impacts take place during the phase of use and concern the energy consumption and the refrigerant leaks. The impact depends also on the geographic situation and on the energy sources used in the country for power generation. (J.S.)

  4. Experimental Determination of Demand Response Control Models and Cost of Control for Ensembles of Window-Mount Air Conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Geller, Drew Adam [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Backhaus, Scott N. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-09-29

    Control of consumer electrical devices for providing electrical grid services is expanding in both the scope and the diversity of loads that are engaged in control, but there are few experimentally-based models of these devices suitable for control designs and for assessing the cost of control. A laboratory-scale test system is developed to experimentally evaluate the use of a simple window-mount air conditioner for electrical grid regulation services. The experimental test bed is a single, isolated air conditioner embedded in a test system that both emulates the thermodynamics of an air conditioned room and also isolates the air conditioner from the real-world external environmental and human variables that perturb the careful measurements required to capture a model that fully characterizes both the control response functions and the cost of control. The control response functions and cost of control are measured using harmonic perturbation of the temperature set point and a test protocol that further isolates the air conditioner from low frequency environmental variability.

  5. 10 CFR Appendix F to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Room Air Conditioners

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Uniform Test Method for Measuring the Energy Consumption of Room Air Conditioners F Appendix F to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY... Appendix F to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of Room Air...

  6. DISPLACEMENT CONTROL AND KINETIC ANALYSIS OF A NOVEL VARIABLE DISPLACEMENT COMPRESSOR FOR AUTOMOTIVE AIR CONDITIONER

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    A novel variable displacement compressor (VDC) for automotive air conditioner (AAC) is introduced, which inherits the advantages of common wobble plate type VDC. It has fewer parts and makes less noise, and inst ead of pneumatic valve the displacement is controlled by electronic control valv e. In order to know the control mechanism well and get a good control effect, a mathematical model for the variable displacement mechanism is developed accordin g to the geometrical and kinematical information of the compressor. Using the mo del, the effect of relevant parameters on variable displace control is estimated . It is helpful to make the optimum decision in the flow control of AAC. As the novel displacement control device, the structure and control rule of electronic control valve is introduced. It can get better effect than the conventional pneu matic valves. And by using this new electronic control device, the optimum syste mic control of AAC is available.

  7. Experimental study on heat transfer performance of aluminium foam parallel-flow condenser in air conditioner

    Science.gov (United States)

    Zhang, X.; Wan, Z. M.; Chang, H. W.; Wang, Y. D.

    2017-01-01

    Open cell aluminium foam was used in parallel-flow condenser in air conditioner, and two condensers with different pore density were fabricated. The experimental study was conducted on the heat transfer performance and temperature distribution. The experimental results show that both of the heat transfer load and air pressure drop increase with the increase of pore density, air velocity is 2.5m/s, the heat transfer capacities of the condenser with 10PPI and 8PPI are 4.786kw and 3.344kW respectively. Along the flow direction of refrigerant, the outlet temperatures of refrigerant drop with the rise of air velocity when the inlet temperature is constant. The outlet temperature of the refrigerant decreases with the increase of pore density.

  8. EFFECT OF AIR CONDITIONER ON PULMONARY FUNCTIONS IN HEALTHY MALES IN AND AROUND RAICHUR CITY

    Directory of Open Access Journals (Sweden)

    Mohammed

    2015-05-01

    Full Text Available INTRODUCTION: Air conditioner by lowering temperature may affect human health since it has profound effect on our environment. Modern styles of living in urban areas have been considered potentially responsible for the development of airway allergic diseases due to pro liferating house dust mites & increasing concentration of indoor air pollutants, which lead to the elevation of serum Ig E levels or the enhancement of eosinophil activity. AIMS AND OBJECTIVE: To assess the effect of air conditioners (AC on pulmonary func tions in young healthy non - smoker male. MATERIALS AND METHOD S : The study group comprised of 20 male subjects who were using AC’s in their cars for at least 1 hr daily since last 6 months. While 20 male subjects who did not use AC at all served as controls. The pulmonary functions were assessed using Power lab 8/30 series with dual bio Amp/stimulator, manufactured by AD instruments, Australia, in a closed room the outcome of pulmonary function tests was presented as a mean ± SD for each of the parameter. The two groups were compared by applying unpaired ‘t’ test and P value of less than 0.05 was considered as significant . RESULTS: The peak expiratory flow rate (PEFR and Forced expiratory flow between 25 – 75% of vital capacity(FEF25 – 75 were significantly redu ced in subjects using car AC’s. CONCLUSION: In the presence of normal FEV1, reduced FEF 25 – 75%, which is the flow rate over the middle half of vital capacity, is an evidence of mild airflow limitation. The result is suggestive of predisposition of AC users towards respiratory disorders in form of mild airflow restriction

  9. Energy efficiency and energy saving air conditioners window and split type; Eficiencia energetica e economia de energia de condicionadores de ar tipo janela e split

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Edson Palhares de; Cardoso, Rafael Balbino; Nogueira, Luiz Augusto Horta [Universidade Federal de Itajuba (EXCEN/UNIFEI), MG (Brazil). Centro de Excelencia em Eficiencia Energetica

    2010-07-01

    The air-conditioners of window end Split type are responsible for a significant portion of energy consumption in residential sector of Brazil, from 20% of the sector. This study evaluates the impact energy of the Seal Program PROCEL in air-conditioners of window end Split type, showing the efficiency gains for the country in terms of energy saving. For this evaluation it was considered the effects of temperature and loss of performance due to age, PROCEL Stamp Program resulted in a power savings of 664 GWh in air-conditioners of window type residential sector in 2008. (author)

  10. Air conditioners: Moisturizers and cooling towers are critical components; Klimaanlagen: Befeuchter und Kuehltuerme als kritische Komponenten

    Energy Technology Data Exchange (ETDEWEB)

    Hackl, W.

    2003-10-15

    The VDI 6022 and VDI 3803 standards contain specifications for air conditioning systems in buildings, on the basis of which BWT developed a comprehensive hygienic concept based on modular technologies that can be combined according to the user's needs and require no chemical additives. [German] Die Richtlinien VDI 6022 und VDI 3803 beschreiben die Anforderungen an Raumlufttechnische Anlagen in der Gebaeudetechnik. Waehrend die VDI 6022 Qualitaetsvorgaben unter dem Blickwinkel der Hygiene macht, werden in den Anlagen und Tabellen der VDI 3803 die zulaessigen Wasserwerte aus technischer Sicht beschrieben. Auf Basis dieser Vorgaben hat BWT ein ganzheitliches Hygiene-Konzept entwickelt. Chemiefreie, je nach Anwendungsfall aufeinander abgestimmte Kombinations-Technologien stehen im Mittelpunkt. (orig.)

  11. Electric efficiency in lighting system and air conditioners replacement and automation of air conditioners split type in public buildings; Eficiencia eletrica na substituicao do sistema de iluminacao e de condicionadores de ar e automacao do sistema de condicionadores de ar tipo split em predios publicos

    Energy Technology Data Exchange (ETDEWEB)

    Vasconcellos, Arnulfo Barroso de; Apolonio, Roberto; Silva, Luciana Oliveira da; Gomes, Fernanda Leles [Universidade Federal de Mato Grosso (UFMT), MT (Brazil); Malheiro, Teresa Irene Ribeiro de Carvalho [Instituto Federal de Educacao, Ciencia e Tecnologia de Mato Grosso (IFMT), MT (Brazil); Barros, Regiane Silva de [Universidade Estadual de Campinas (UNICAMP), SP (Brazil)

    2010-07-01

    The reduction in expenditure on electricity is a major benefit not only consumers but also to utilities. In this context, this article examines the process of replacing the system of internal lighting, window type air conditioners and automation of Split type air conditioners from buildings of public institutions of the state of Mato Grosso during 2009 year and verifies the reduction in annual consumption of electric power and demand active power. Thus, measurements and calculations performed are presented for the interior lighting systems and air conditioners of these buildings before and after implementation of the process of replacing the system of internal lighting and window type air conditioners and automation of Split type air conditioners. This work is the result of integration among the Dealer Network Energy Rede Cemat, the Federal University of Mato Grosso (UFMT) and the Administration of all public buildings, where the academy answered these real issues, solving the specific problem presented. (author)

  12. Strategy Guideline: HVAC Equipment Sizing

    Energy Technology Data Exchange (ETDEWEB)

    Burdick, A.

    2012-02-01

    The heating, ventilation, and air conditioning (HVAC) system is arguably the most complex system installed in a house and is a substantial component of the total house energy use. A right-sized HVAC system will provide the desired occupant comfort and will run efficiently. This Strategy Guideline discusses the information needed to initially select the equipment for a properly designed HVAC system. Right-sizing of an HVAC system involves the selection of equipment and the design of the air distribution system to meet the accurate predicted heating and cooling loads of the house. Right-sizing the HVAC system begins with an accurate understanding of the heating and cooling loads on a space; however, a full HVAC design involves more than just the load estimate calculation - the load calculation is the first step of the iterative HVAC design procedure. This guide describes the equipment selection of a split system air conditioner and furnace for an example house in Chicago, IL as well as a heat pump system for an example house in Orlando, Florida. The required heating and cooling load information for the two example houses was developed in the Department of Energy Building America Strategy Guideline: Accurate Heating and Cooling Load Calculations.

  13. System performance and economic analysis of solar-assisted cooling/heating system

    KAUST Repository

    Huang, B.J.

    2011-11-01

    The long-term system simulation and economic analysis of solar-assisted cooling/heating system (SACH-2) was carried out in order to find an economical design. The solar heat driven ejector cooling system (ECS) is used to provide part of the cooling load to reduce the energy consumption of the air conditioner installed as the base-load cooler. A standard SACH-2 system for cooling load 3.5. kW (1. RT) and daily cooling time 10 h is used for case study. The cooling performance is assumed only in summer seasons from May to October. In winter season from November to April, only heat is supplied. Two installation locations (Taipei and Tainan) were examined.It was found from the cooling performance simulation that in order to save 50% energy of the air conditioner, the required solar collector area is 40m2 in Taipei and 31m2 in Tainan, for COPj=0.2. If the solar collector area is designed as 20m2, the solar ejector cooling system will supply about 17-26% cooling load in Taipei in summer season and about 21-27% cooling load in Tainan. Simulation for long-term performance including cooling in summer (May-October) and hot water supply in winter (November-April) was carried out to determine the monthly-average energy savings. The corresponding daily hot water supply (with 40°C temperature rise of water) for 20m2 solar collector area is 616-858L/day in Tainan and 304-533L/day in Taipei.The economic analysis shows that the payback time of SACH-2 decreases with increasing cooling capacity. The payback time is 4.8. years in Tainan and 6.2. years in Taipei when the cooling capacity >10. RT. If the ECS is treated as an additional device used as a protective equipment to avoid overheating of solar collectors and to convert the excess solar heat in summer into cooling to reduce the energy consumption of air conditioner, the payback time is less than 3 years for cooling capacity larger than 3. RT. © 2011 Elsevier Ltd.

  14. Corrosion Resistance of Zn and Cu Coated Steel Pipes as a Substitute for Cu Pipe in an Air Conditioner System

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Jae Gyeong; Park, Chan Jin; Hong, Sung Kil [Chonnam National University, Gwangju (Korea, Republic of)

    2009-02-15

    We investigated the corrosion resistance of Zn and Cu coated steel pipes as a substitute for Cu pipe in an air-conditioner system. In addition, the galvanic corrosion tendency between two dissimilar metal parts was studied. The corrosion resistance of the Cu electroplated steel was similar to that of Cu, while the corrosion rate of the Zn electro-galvanized and the galvalume (Zn-55 % Al) coated steels was much higher and not suitable for Cu substitute in artificial sea water and acidic rain environments. Furthermore, the galvanic difference between Cu electroplated steel and Cu was so small that the Cu coated steel pipe can be used as a substitute for Cu pipe in an air-conditioner system.

  15. Utilization of condensate water from evaporator of portable air conditioner%移动式空调机蒸发器冷凝水的利用

    Institute of Scientific and Technical Information of China (English)

    鲁贤德

    2012-01-01

    How to use the condensate water from evaporator of portable air conditioner is analyzed An improved method to increase the energy efficiency of portable air conditioner is studied.%对如何利用移动式空调机蒸发器产生的冷凝水进行分析,探讨提升移动式空调机能效比的一种改进方法.

  16. Use of nanoparticles to make mineral oil lubricants feasible for use in a residential air conditioner employing hydro-fluorocarbons refrigerants

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Ruixiang [School of Energy and Power Engineering, Xi' an Jiaotong University 710049 Xi' an (China); School of Environment and Energy Engineering, Beijing University of Civil Engineering and Architecture, No. 1, Zhanlan Guan Road, Beijing 100044 (China); Wu, Qingping; Wu, Yezheng [School of Energy and Power Engineering, Xi' an Jiaotong University 710049 Xi' an (China)

    2010-11-15

    The application of nano-fluids in refrigerating systems is considered to be a potential way to improve the energy efficiency and reliability of HVAC and R facilities and to make economic the use of environment-friendly refrigerants. In this paper, we report a method that uses nanoparticles to enhance the energy efficiency of retrofitted residential air conditioners (RAC) employing HFCs as alternative refrigerants. The reliability and performance of RAC with nanoparticles in the working fluid have been investigated experimentally. A new mineral-based nano-refrigeration oil (MNRO), formed by blending some nanoparticles (NiFe{sub 2}O{sub 4}) into naphthene based oil B32, was employed in the RAC using R410a as refrigerant. A method showing how to disperse the NiFe{sub 2}O{sub 4} nanoparticles in the mineral oil refrigeration lubricants is presented together with an investigation of their stability. The solubilities of the new MNRO in R134a, R407C, R410a and R425a were measured. The performances of the RAC, such as the cooling/heating capacity, the power input and the energy efficiency ratio, were determined. The results indicate that the mixture of R410a/MNRO works normally in the RAC. The cooling/heating EER of the RAC increased about 6% by replacing the Polyol-Easter oil VG 32 lubricant with MNRO. (author)

  17. Numerical Simulation of the Influence of Elliptical Tube Heat Exchanger in Indoor Unit of Air Conditioner on its Acoustic Field%椭圆管换热器对空调室内机声场影响的数值模拟

    Institute of Scientific and Technical Information of China (English)

    周遊; 张新强; 汪双凤

    2016-01-01

    Elliptical tube heat exchanger has been widely used in heat exchange equipment due to its good flow and heat transfer charac⁃teristics. In this paper we use computational fluid dynamics method to simulate the flow field and sound field generated by the indoor unit of air conditioner with elliptical finned tube heat exchanger , and make comparison with circular tube heat exchanger. The results show that for the inside the cross-flow, the structure of tubes in heat exchangers has no effect on the location and size of the eccentric vortex;compared with the circular tube finned heat exchanger with the same cross-sectional area, the air conditioners using elliptical tubes work better on increasing the air volume, improving cooling effect and reducing noise especially low-frequency noise under the same condi⁃tions. Above all, the conditioner using elliptical tubes in which the ratio of the long axis and short axis is 2. 0 can reduce noise 4 dB.%椭圆管换热器由于良好的流动和换热特性,在换热设备中有广泛的应用。本文利用计算流体力学方法,对椭圆管翅片换热器应用于空调室内机的流场和声场进行数值模拟,并与圆管作对比。计算结果表明,换热管形状对贯流风机内部偏心涡的形成位置和大小没有影响;与采用相同截面积的圆管翅片换热器的室内机相比,相同条件下,采用椭圆管换热器对于室内机增加风量,改善制冷性能,降低噪声尤其是低频噪声方面有良好的效果。其中,长短轴之比为2的椭圆管可以降低室内机噪声4 dB。

  18. Alternative Refrigerant Evaluation for High-Ambient-Temperature Environments: R-22 and R-410A Alternatives for Rooftop Air Conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Abdelaziz, Omar [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Shrestha, Som S. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Shen, Bo [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Linkous, Randall Lee [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Goetzler, William [Navigant Consulting Inc., Burlington, MA (United States); Guernsey, Matt [Navigant Consulting Inc., Burlington, MA (United States); Bargach, Youssef [Navigant Consulting Inc., Burlington, MA (United States)

    2016-09-01

    The Oak Ridge National Laboratory (ORNL) High-Ambient-Temperature Evaluation Program for Low-Global Warming Potential (Low-GWP) Refrigerants aims to develop an understanding of the performance of low-GWP alternative refrigerants relative to hydrochlorofluorocarbon (HCFC) and hydrofluorocarbon (HFC) refrigerants in packaged or Rooftop Unit (RTU) air conditioners under high-ambient-temperature conditions. This final report describes the parties involved, the alternative refrigerants selection process, the test procedures, and the final results.

  19. Performance Improvement of EMQ Bearings for Air-Conditioner%空调电机轴承的性能改进

    Institute of Scientific and Technical Information of China (English)

    王冰

    2013-01-01

      依据调查结果阐述、分析空调电机轴承国产化现状及存在问题,论述问题产生原因并提出改进建议。%Based on findings of the investigation,elaborate and analyse current situation and existing issues of localized EMQ bearings for air-conditioners. Illustrate the root cause of issues and propose the actions to improve.

  20. he Efficiency Analysis of Room Air Conditioners%房间空气调节器的效率分析

    Institute of Scientific and Technical Information of China (English)

    周子成

    2013-01-01

    本文介绍和论述房间空调器的效率现状及其提高的途径,如高效压缩机、高效换热器、变频驱动等。%The efficiency status of room air conditioners and its improving ways are introduced and discussed in this paper , such as high-efficiency compressors , high efficiency heat exchangers , and inverter drives etc..

  1. Effect of central ventilation and air conditioner system on the concentration and health risk from airborne polycyclic aromatic hydrocarbons

    Institute of Scientific and Technical Information of China (English)

    Jinze LV; Lizhong Zhu

    2013-01-01

    Central ventilation and air conditioner systems are widely utilized nowadays in public places for air exchange and temperature control,which significantly influences the transfer of pollutants between indoors and outdoors.To study the effect of central ventilation and air conditioner systems on the concentration and health risk from airborne pollutants,a spatial and temporal survey was carried out using polycyclic aromatic hydrocarbons (PAHs) as agent pollutants.During the period when the central ventilation system operated without air conditioning (AC-off period),concentrations of 2-4 ring PAHs in the model supermarket were dominated by outdoor levels,due to the good linearity between indoor air and outdoor air (rp > 0.769,p < 0.05),and the slopes (1.2-4.54) indicated that ventilating like the model supermarket increased the potential health risks from low molecular weight PAHs.During the period when the central ventilation and air conditioner systems were working simultaneously (AC-on period),although the total levels of PAHs were increased,the concentrations and percentage of the particulate PAHs indoors declined significantly.The BaP equivalency (BaPeq concentration indicated that utilization of air conditioning reduced the health risks from PAHs in the model supermarket.

  2. Effect of central ventilation and air conditioner system on the concentration and health risk from airborne polycyclic aromatic hydrocarbons.

    Science.gov (United States)

    Lv, Jinze; Zhu, Lizhong

    2013-03-01

    Central ventilation and air conditioner systems are widely utilized nowadays in public places for air exchange and temperature control, which significantly influences the transfer of pollutants between indoors and outdoors. To study the effect of central ventilation and air conditioner systems on the concentration and health risk from airborne pollutants, a spatial and temporal survey was carried out using polycyclic aromatic hydrocarbons (PAHs) as agent pollutants. During the period when the central ventilation system operated without air conditioning (AC-off period), concentrations of 2-4 ring PAHs in the model supermarket were dominated by outdoor levels, due to the good linearity between indoor air and outdoor air (r(p) > 0.769, p supermarket increased the potential health risks from low molecular weight PAHs. During the period when the central ventilation and air conditioner systems were working simultaneously (AC-on period), although the total levels of PAHs were increased, the concentrations and percentage of the particulate PAHs indoors declined significantly. The BaP equivalency (BaPeq) concentration indicated that utilization of air conditioning reduced the health risks from PAHs in the model supermarket.

  3. Life cycle analysis of retrofitting with high energy efficiency air-conditioner and fluorescent lamp in existing buildings

    Energy Technology Data Exchange (ETDEWEB)

    Techato, Kua-anan [International Postgraduate Programs in Environmental Management (Hazardous Waste Management) and ERI (Energy Research Institute), Chulalongkorn University, Bangkok 10330 (Thailand); Watts, Daniel J. [Otto H. York Center for Environmental Engineering and Science, New Jersey Institute of Technology, Newark, NJ 07102 (United States); Chaiprapat, Sumate [Department of Civil Engineering, Faculty of Engineering, Prince of Songkla University, Hat Yai Campus, Hat Yai, Songkhla 90112 (Thailand); National Center of Excellence for Environmental and Hazardous Waste Management-Satellite Center at Prince of Songkla University (Thailand)

    2009-01-15

    Life cycle analysis of mercury in discarded low energy efficiency fluorescent lamps (36 W) and of HCFC in air-conditioners (12,000 Btu) removed from service has been conducted in this study. The objective was to find out the environmental impact (EDIP 1997 category, waste evaluation) of the products that appear in the waste stream as a result of facility upgrades. The scope of the study starts from retrofitting of the lamps and air-conditioners through recycling and disposal. For a 36 W fluorescent lamp, the bulk waste 1.64E-5 kg, hazardous waste 1.11E-4 kg, radioactive waste 1.09E-9 kg, and slag-ash 6.02E-7 kg occurred at the end of life of the retrofitting cycle. For a 12,000 Btu air-conditioner, the bulk waste 0.58 kg, hazardous waste 0.11 kg, radioactive waste 0.0002 kg, and slag-ash 0.01 kg also occurred at the end of life of the retrofitting cycle. These small amounts become important when viewed at the country level. These quantities imply that the policy makers who deal with hazardous waste should be aware of this waste-generating characteristic before issuing any pertinent policy. Consideration of this characteristic and planning for appropriate waste management methods at the beginning stage will reduce any future problem of contamination by the hazardous waste. (author)

  4. Field evaluation of advanced controls for the retrofit of packaged air conditioners and heat pumps

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Weimin; Katipamula, Srinivas; Ngo, Hung; Underhill, Ronald M.; Taasevigen, Danny J.; Lutes, Robert G.

    2015-09-01

    This paper documents the magnitude of energy savings achievable in the field by retrofitting existing packaged rooftop units (RTUs) with advanced control strategies not ordinarily used for RTUs. A total of 66 RTUs on 8 different buildings were retrofitted with a commercially available advanced controller for improving RTU operational efficiency. The controller features enhanced air-side economizer control, multi-speed fan control, and demand controlled ventilation. Of the 66 RTUs, 18 are packaged heat pumps and the rest are packaged air conditioners with gas heat. The eight buildings cover four building types and four climate conditions. Based on the data collected for about a whole year, the advanced controller reduced the normalized annual RTU energy consumption between 22% and 90%, with an average of 57% for all RTUs. The average fractional savings uncertainty was 12% at 95% confidence level. Normalized annual electricity savings were in the range between 0.47 kWh/h (kWh per hour of RTU operation) and 7.21 kWh/h, with an average of 2.39 kWh/h. RTUs greater than 53 kW and runtime greater than 14 hours per day had payback periods less than 3 years even at $0.05/kWh.

  5. Flow control of a centrifugal fan in a commercial air conditioner

    Science.gov (United States)

    Kim, Jiyu; Bang, Kyeongtae; Choi, Haecheon; Seo, Eung Ryeol; Kang, Yonghun

    2015-11-01

    Air-conditioning fans require a low noise level to provide user comfort and quietness. The aerodynamic noise sources are generated by highly unsteady, turbulent structures near the fan blade. In this study, we investigate the flow characteristics of a centrifugal fan in an air-conditioner indoor unit and suggest control ideas to develop a low noise fan. The experiment is conducted at the operation condition where the Reynolds number is 163000 based on the blade tip velocity and chord length. Intermittent separation occurs at the blade leading edge and thus flow significantly fluctuates there, whereas vortex shedding occurs at the blade trailing edge. Furthermore, the discharge flow observed in the axial plane near the shroud shows low-frequency intermittent behaviors, resulting in high Reynolds stresses. To control these flow structures, we modify the shapes of the blade leading edge and shroud of the centrifugal fan and obtain noise reduction. The flow characteristics of the base and modified fans will be discussed. Supported by 0420-20130051.

  6. Development and testing of a multi-type air conditioner without using AC inverters

    Energy Technology Data Exchange (ETDEWEB)

    Shih-Cheng Hu; Rong-Hwa Yang [National Taipei University of Technology (China). Dept. of Air Conditioning and Refrigeration Engineering

    2005-02-01

    This paper reports the results from the development and performance testing of a cost effective, energy efficient, multi-type air conditioner that connected five indoor units (evaporators) to one outdoor unit (condenser) with a digital scroll compressor. Instead of using inverter technology, which has a potential risk of harmonic current emissions, this study used a digital scroll compressor, which provided the variable refrigerant volumes. The measured results for this innovative design showed: (1) The relationship between the degree of opening of the electronic expansion valves (s) and the compressor output ratio (%) could be represented by regression functions, which formed the basic parameters of the system control. (2) The developed system provided true zoning capability because it could run indoor units under part load conditions, therefore wasting little energy. The power consumption of the developed system was reduced from 1 00% to 25% when the full load was reduced to a partial load of 17%, saving more than 75% of the work required using a conventional unloading method. (3) The developed system has a broader range of capacity output (from 17% to 100%) than that of an AC variable frequency control system (from 48% to 104%). The developed system cost 20% less than a comparable system with an AC inverter. (author)

  7. The System Impact of Air-Conditioner Under-voltage Protection Schemes

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Ning; Yang, Bo; Huang, Zhenyu; Bravo, Richard

    2009-03-31

    This paper presents simulation results of evaluating an under-voltage protection scheme designed to take stalled air-conditioner (a/c) units offline such that the slow voltage recovery phenomena can be solved on areas heavily loaded with a/c motors during summer peak periods. A three feeder test-bed has been first used to quantify the effectiveness of the protection scheme and the sensitivity of the under-voltage relay settings. Then two real system events of the Western US power grid have been studied to evaluate the area impact of the protection scheme proposed by Southern California Edison. The study demonstrates that by taking all or most of the stalled a/c unit offline, the feeder voltage will recover in a few seconds, much quicker than the tens of seconds that the standard thermal relays imbedded in the motors need to trip the units. The drawback of the control scheme is that after the voltage recover, it settled at a higher voltage than before the faults because a large chuck of load has been shed.

  8. Development and testing of a multi-type air conditioner without using AC inverters

    Energy Technology Data Exchange (ETDEWEB)

    Hu, S.-C. E-mail: f10870@ntut.edu.tw; Yang, R.-H

    2005-02-01

    This paper reports the results from the development and performance testing of a cost effective, energy efficient, multi-type air conditioner that connected five indoor units (evaporators) to one outdoor unit (condenser) with a digital scroll compressor. Instead of using inverter technology, which has a potential risk of harmonic current emissions, this study used a digital scroll compressor, which provided the variable refrigerant volumes. The measured results for this innovative design showed: (1) The relationship between the degree of opening of the electronic expansion valves (s) and the compressor output ratio (%) could be represented by regression functions, which formed the basic parameters of the system control. (2) The developed system provided true zoning capability because it could run indoor units under part load conditions, therefore wasting little energy. The power consumption of the developed system was reduced from 100% to 25% when the full load was reduced to a partial load of 17%, saving more than 75% of the work required using a conventional un-loading method. (3) The developed system has a broader range of capacity output (from 17% to 100%) than that of an AC variable frequency control system (from 48% to 104%). The developed system cost 20% less than a comparable system with an AC inverter.

  9. Technology Roadmaps: Energy-efficient Buildings: Heating and Cooling Equipment

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-07-01

    Buildings account for almost a third of final energy consumption globally and are an equally important source of CO2 emissions. Currently, both space heating and cooling as well as hot water are estimated to account for roughly half of global energy consumption in buildings. Energy-efficient and low/zero-carbon heating and cooling technologies for buildings have the potential to reduce CO2 emissions by up to 2 gigatonnes (Gt) and save 710 million tonnes oil equivalent (Mtoe) of energy by 2050. Most of these technologies -- which include solar thermal, combined heat and power (CHP), heat pumps and thermal energy storage -- are commercially available today. The Energy-Efficient Buildings: Heating and Cooling Equipment Roadmap sets out a detailed pathway for the evolution and deployment of the key underlying technologies. It finds that urgent action is required if the building stock of the future is to consume less energy and result in lower CO2 emissions. The roadmap concludes with a set of near-term actions that stakeholders will need to take to achieve the roadmap's vision.

  10. Design of a novel solar air conditioner using a solid-phase absorber. Phase 1. Draft final report, September 20, 1977-September 30, 1978

    Energy Technology Data Exchange (ETDEWEB)

    Offenhartz, P O.D.; Marston, J M; Brown, F C; Mattos, C; Harrington, L; Brummer, S B

    1978-01-01

    Experimental and analytical work carried out in Phase I of this program indicate that the reaction of CaCl/sub 2/.H/sub 2/O (calcium chloride monohydrate) with H/sub 2/O vapor to form CaCl/sub 2/.2H/sub 2/O (dihydrate) is thermodynamically and kinetically suitable for use in a solid-phase absorption solar air conditioner with built-in energy storage. The calculated thermal coefficient of performance is 0.69 or greater, with forced air heat rejection to ambient air at 95/sup 0/F. The required solar collector temperature should be about 250/sup 0/F. Electric power pumping requirements should be modest since no fluid recirculation is involved, and since the novel finned-tube-in container heat exchanger has been designed for low pressure drop as well as high effectiveness. Furthermore, the salt pellet container/heat exchanger is quite compact, since the storage energy density is approximately 6000 Btu/ft/sup 3/. The complete cost of a 3-ton residential cooling system with sufficient storage for 100% solar operation is projected to be about $15,000, excluding only the collector. This cost includes provision for domestic hot water heating and winter space heating at a thermal coefficient of performance ca. 1.7.

  11. Thermal comfort and indoor air quality in the lecture room with 4-way cassette air-conditioner and mixing ventilation system

    Energy Technology Data Exchange (ETDEWEB)

    Noh, Kwang-Chul; Jang, Jae-Soo; Oh, Myung-Do [Department of Mechanical and Information Engineering, University of Seoul, Seoul 130-743 (Korea, Republic of)

    2007-02-15

    We performed the experimental and the numerical studies on thermal comfort (TC) and indoor air quality (IAQ) in the lecture room with cooling loads when the operating conditions are changed. Predicted mean vote (PMV) value and CO{sub 2} concentration of the lecture room were measured and compared to the numerical results. Both of them showed a reasonable agreement with each other and then we applied the numerical model to analyze TC and IAQ for a couple of different operating conditions. From the results we found that the increment of the discharge angle of 4-way cassette air-conditioner makes uniformity of TC worse, but rarely affects IAQ. It turned out that TC and IAQ are hardly affected by the variation of the discharge airflow. Finally TC was merely affected by the increment of the ventilation rate, but when the ventilation rate is more than 800m{sup 3}/h, the average CO{sub 2} concentration can be satisfied with the standard limits of Japanese in our case studies. (author)

  12. Experimental study of a R-407C drop-in test on an off-the-shelf air conditioner with a counter-cross-flow evaporator

    Energy Technology Data Exchange (ETDEWEB)

    Mei, V.C.; Domitrovic, R.; Chen, F.C.

    1998-03-01

    An off-the-shelf 2-ton window air conditioner having an energy efficiency ratio of 10 was used to perform a drop-in test with R-407C. Laboratory tests were performed using a parallel-cross-flow (PCF) evaporator and a counter-cross-flow (CCF) evaporator. The CCF configuration is designed to take advantage of the temperature glide of R-407C so that the warm evaporator inlet air will be in contact with the higher temperature part of the evaporator coils first. The test results indicated that, at the Air Conditioning and Refrigeration Institute-rated indoor and outdoor conditions, the cooling capacity was 8% higher and system coefficient of performance about 3.8% higher for the CCF evaporator than for the PCF evaporator. The test results also showed that the latent load for CCF was 30.6% higher than for PCF. The far better dehumidification effect provided by the CCF evaporator design is desirable for areas where the latent load is high. The experimental findings should be useful for future efforts to design a dehumidifier that uses a zeotropic refrigerant that provides a significant temperature glide. R-22 test data from a previous project are included as a reference.

  13. Chemical Risk Evaluation: A Case Study in an Automotive Air Conditioner Production Facility

    Directory of Open Access Journals (Sweden)

    Tengku Hanidza T.I.

    2010-01-01

    Full Text Available There has been limited knowledge on worker’s exposure to chemicals used in the automotive industries. The purpose of this study is to assess chemical risk and to determine the adequacy of the existing control measures to reduce chemical exposure. A cross sectional survey was conducted in a factory involving installation and servicing of automotive air conditioner units. Qualitative exposure assessment was carried out following the Malaysian Chemical Health Risk Assessment Manual (CHRA. There were 180 employees, 156 workers worked in the production line, which constitutes six work units Tube fin pressed, Brazing, Welding, Final assembly, Piping and Kit II. From the chemical risk evaluation for each work unit, 26 chemical compounds were used. Most of the chemicals were irritants (eye and skin and some were asphyxiants and sensitizers. Based on the work assignment, 93 out of 180 (51.67% of the workers were exposed to chemicals. The highest numbers of workers exposed to chemicals were from the Brazing section (22.22% while the Final Assembly section was the lowest (1.67%. Health survey among the workers showed occurrence of eye irritation, skin irritation, and respiratory irritation, symptoms usually associated with chemical exposure. Using a risk rating matrix, several work process were identified as having ‘significant risk’. For these areas, the workers are at risk of adverse health effects since chemical exposure is not adequately controlled. This study recommends corrective actions be taken in order to control the level of exposure and to provide a safe work environment for workers.

  14. 连接管在空调器降成本机型中的灵活运用%Flexible application of connecting pipe into the cost reduction machine type of air conditioner

    Institute of Scientific and Technical Information of China (English)

    冼志健; 梁勤奋

    2012-01-01

    在原有空调器配置不变的前提下,空调器连接管的灵活搭配应用,不但可以改善空调器制冷效果,而且能够降低空调器整机成本,提高其市场竞争力.%Under the original air conditioner configuration unchanged, the application of flexible collocation into air conditioner's connecting pipe,not only can improve the refrigeration effect of air conditioner,but also can reduce the cost of air conditioner and improve their market competitiveness.

  15. Fighting Fire with Fire: Superlattice Cooling of Silicon Hotspots to Reduce Global Cooling Requirements

    Energy Technology Data Exchange (ETDEWEB)

    Biswas, S; Tiwari, M; Sherwood, T; Theogarajan, L; Chong, F T

    2010-10-05

    The running costs of data centers are dominated by the need to dissipate heat generated by thousands of server machines. Higher temperatures are undesirable as they lead to premature silicon wear-out; in fact, mean time to failure has been shown to decrease exponentially with temperature (Black's law). Although other server components also generate heat, microprocessors still dominate in most server configurations and are also the most vulnerable to wearout as the feature sizes shrink. Even as processor complexity and technology scaling have increased the average energy density inside a processor to maximally tolerable levels, modern microprocessors make extensive use of hardware structures such as the load-store queue and other CAM-based units, and the peak temperatures on chip can be much worse than even the average temperature of the chip. In recent studies, it has been shown that hot-spots inside a processor can generate {approx} 800W/cm{sup 2} heat flux whereas the average heat flux is only 10-50W/cm{sup 2}, and due to this disparity in heat generation, the temperature in hot spots may be up to 30 C more than average chip temperature. The key problem processor hot-spots create is that in order to prevent some critical hardware structures from wearing out faster, the air conditioners in a data center have to be provisioned for worst case requirements. Worse yet, air conditioner efficiencies decrease exponentially as the desired ambient temperature decreases relative to the air outside. As a result, the global cooling costs in data centers, which nearly equals the IT equipment power consumption, are directly correlated with the maximum hot spot temperatures of processors, and there is a distinct requirement for a cooling technique to mitigate hot-spots selectively so that the global air conditioners can operate at higher, more efficient, temperatures. We observe that localized cooling via superlattice microrefrigeration presents exactly this opportunity

  16. 一种多效应移动式节能环保空调设计%Design of mobile energy-saving air-conditioner with multiple effects

    Institute of Scientific and Technical Information of China (English)

    卢满怀; 汤绮婷; 于晓光

    2012-01-01

    It introduces the design of a kind of energy saving air-conditioner with multi- effects,with normal water as refrigerant, by applying comprehensively triple refrigeration technology of the air-conditioner covering water surface evaporative refrigeration,semiconductor refrigeration and heat lithium bromide absorption refrigerationAt the same time, higher environmental cleanliness and the result of cooling efficiency are realized by increasing air flow and controlling temperature and humidity.The experiment evidences that the new air-conditioner is more creative in energy conservation, emission reduction,human comfort improvement as well as convenience in use,cost and price than the traditional oneAs the air-conditioning design principles is not the same with the traditional, no fixed installation is necessary,which can be applied not only in open environment but also in densely populated areas for improving the quality of air and decreasing the temperature with significant advantages in the cooling rate,health,economy,and environmental protection.%介绍了一种以常态水为冷媒,综合应用水表面蒸发制冷、半导体制冷和溴化锂吸收半导体余热制冷的三重制冷技术的多效应移动式节能环保空调;同时,通过加大风流量和温湿度的控制,实现提高环境洁净度和制冷效率的效果.实验证明,与传统空调相比,研究的环保空调在节能减排、提高人体舒适度、使用便捷性、价格成本等方面有很大的创新.由于空调的设计原理与传统空调不一样,无需固定安装,使用环境可开放式,在人口密集地方既能降温又能提高空气的质量,在降温速度、卫生、经济、环保等方面有显著的优点.

  17. 机车空调电源的比较与分析%Comparison and Analysis of Locomotive Air-conditioner Power Supply

    Institute of Scientific and Technical Information of China (English)

    陈泽武

    2013-01-01

    总结了内燃机车、电力机车常用的空调电源的电路结构形式,简单探讨了空调电源电路的设计要点,并对电力机车的交直交与直交2种形式的空调电源电路进行了较为详细的对比分析,指出了各自的优点与不足;同时,介绍了机车空调电源变频调速的一般性原理,比较了定频与变频机车空调电源各自的优缺点.%Circuit structures of air-conditioner power supply for diesel locomotive and electric locomotive were summarized,and key points of air-conditioner power supply design were discussed.Two types of air-conditioner power supply circuit i.e.AC/DC/AC and DC/AC convert circuit were compared in detail,advantages and defects of which were pointed out.At the same time,principle of air-conditioner variable frequency speed regulation was introduced,as well as the characteristics of fix-frequency and vari-frequency air-conditioner was compared.

  18. 基于复合热源的热泵型空调器%Heat pump air conditioner based on multiple heat sources

    Institute of Scientific and Technical Information of China (English)

    吴国珊; 凌勋

    2012-01-01

    It is proposed that the air-water multiple heat sources could be the heat source of heat pump air conditioner. Based on the current study condition, the heat pump air conditioner which has a air/family waste water multiple heat source is preliminary designed. The working cycle and characteristics of the air conditioner are analyzed by using the thermodynamic principle. The results show that the refrigeration performance of the heat pump air conditioner is better than that of air source heat pump air conditioner, the heating performance and the situation which the outdoor heat exchanger frosts are improved.%提出将空气-水作为热泵型空调器的复合热源.根据当前的研究状况,初步设计空气-水复合热源热泵型空调器,利用热力学原理分析该空调器的工作循环和特点,结果表明该空调器的制冷性能高于空气源热泵空调器,制热和室外换热器结霜状况得到一定改善.

  19. Choice of a system for heat recovery. Efficiency of an air conditioner; Systeemkeuze voor warmteterugwinning. Meer efficientie uit luchtbehandelingsinstallatie

    Energy Technology Data Exchange (ETDEWEB)

    Van Gorkom, F.H.J.

    2004-05-01

    The use of heat recovery in an air conditioning system improves the efficiency. An overview is given of different air conditioners where heat recovery is applied: twincoil, heat exchanger, heat wheel, and the Kantherm system. [Dutch] Warmteterugwinning levert efficiente luchtbehandelingsinstallaties op. Voor het toepassen van warmteterugwinning is een aantal systemen beschikbaar. In dit artikel komen zowel de twincoil, de platenwisselaar, het warmtewiel en het Kantherm-systeem aan bod. De systemen worden kort beschreven en daarnaast beoordeeld op hun rendement, toepassingsmogelijkheden, voor- en nadelen en kosten voor de levenscyclus.

  20. Discussion on Refitting Air Conditioner on EVs%关于电动汽车空调改装探讨

    Institute of Scientific and Technical Information of China (English)

    谷丰

    2011-01-01

    Based on the analysis and explanation of its working principle and refitting method, the author presents the basic thinking of electric refit of air conditioner on traditional vehicles.%针对纯电动汽车空调在传统汽车空调基础上的改装,结合其工作原理及改装方法进行一定的分析说明,提出对传统汽车空调电动化改装的基本思路。

  1. Design and Techno-economic Analysis of Domestic Solar Bubble Pump Driven Absorption Air-conditioner%一种家用太阳能气泡泵吸收式空调的系统设计与技术经济性分析

    Institute of Scientific and Technical Information of China (English)

    谢应明; 周兴法; 舒欢; 刘道平; 刘妮

    2014-01-01

    In order to effectively solve the problems of high power consumption and noisy in traditional domestic air conditioner , a new type of domestic solar bubble pump absorption air-conditioner was developed .In this air conditioner , the lithium-bromide ab-sorption chiller was driven by solar and the traditional mechanical pump was replaced by the bubble pump .Under the design re-quirement of cooling capacity of 16.5kW and heating capacity of 18.0kW, bubble pump with inner diameter of 0.05m and im-mersed height of 0.5m, solar collector with area of 20m2 and heat storage tank with volume of 1m3 were selected by theoretical calculation.Finally, techno-economic comparison of this apparatus with traditional air-conditioner shows that the solar bubble pump absorption air conditioner has greater superiority .%为了有效解决传统家用空调的高耗电和噪声问题,开发了一种新型的家用太阳能气泡泵吸收式空调装置。该装置采用太阳能驱动溴化锂吸收式制冷机组,并以气泡泵代替传统的机械泵。在空调制冷量为16.5kW和制热量为18.0kW的设计要求下,通过理论计算选择内径为0.05m和沉浸高度为0.5m的气泡泵、集热面积为20m2太阳能集热器以及容积为1m3的蓄热水槽。最后,将该装置与普通家用空调进行技术经济比较,得出太阳能气泡泵吸收式空调有很大的优越性。

  2. 空调运行管理中的节能研究%Energy-saving research in operation management of air-conditioners

    Institute of Scientific and Technical Information of China (English)

    王元

    2012-01-01

    对空调系统运行管理中的节能进行了研究,并对空调系统运行管理的节能基础及节能措施进行了分析,通过采取良好的节能措施降低空调系统的能源消耗,从而有利于社会经济的良好发展。%The paper studies the energy-saving in the operation management of the air-conditioner system,analyzes the energy-saving foundation and the energy-saving measures of the operation management of the air-conditioner system,and reduces the source consumption of the air-conditioner system by adopting better energy-saving measures,so as to enhance the better development of the society and economy.

  3. R407C在客车空调中的应用技术%Application Technology of R407C to Bus/Coach Air-conditioner

    Institute of Scientific and Technical Information of China (English)

    周玉文

    2015-01-01

    The author introduces the calculation method of R407C and R134a theoretical thermodynamic cycle, an-alyzes the effects variation of R407C on the bus/coach air-conditioner performance, and the selection of parts and materials for R407C bus/coach air-conditioner. This can provide a reference for the design of R407C bus/coach air-conditioner.%介绍R407C与R134a理论热力循环计算方法;对R407C客车空调系统性能的变化、零部件和材料的选用进行技术分析;为R407C客车空调器的研发设计提供参考。

  4. 谈建筑暖通空调的设计要点%On design for architectural heat-ventilation air-conditioners

    Institute of Scientific and Technical Information of China (English)

    王康成

    2015-01-01

    The paper indicates the concept for the heat-ventilation air-conditioner system,describes its basic key points of design from the design planning,loading calculation of air-conditioners,and ventilation system design,and puts forward the matters needing attention in the design,so as to ensure the design quality of the heat-ventilation air-conditioner system.%简述了暖通空调系统的含义,从设计规划、空调负荷计算、通风系统设计等方面,论述了建筑暖通空调的基本设计要点,提出了在设计中应该注意的问题,以保证暖通空调系统的设计质量。

  5. 带冷凝热回收的家用空调器的研究%Study on domestic air conditioner with condensing heat recovery

    Institute of Scientific and Technical Information of China (English)

    史德福; 陈华; 黄耀坤

    2012-01-01

    随着生活水平的提高,家用空调器的使用逐年增加.空调器在夏季向室内供冷的同时,不仅给室外环境造成了热污染,而且还造成了能源的浪费.因此,很多学者都提出了空调冷凝热回收理论并进行了实验研究.文中分析了在家用空调器回收冷凝热的可行性及研究现状;介绍了家用空调器采用的冷凝热回收系统的形式及其分类;提出了一种带冷凝热回收装置的多功能热泵系统,并对该系统循环加热式冷凝热回收进行了实验研究和分析.%With tne improvement of living standards, the use of domestic air conditioner gradually increases year by year. In summer, air conditioner will consume a lot of energy for maintaining indoor air conditions and discharge lots of condensation heat into the environment which cause the environmental thermal pollution and waste of energy. Therefore, many scholars have put forward the theory and carried out the experimental studies on air conditioner with condensing heat recovery. In this study, the feasibility of recycling condensing heat on domestic air conditioner was analyzed. The form and assortment of air conditioner system with the condensing heat recovery were introduced. A multi functional hybrid domestic air conditioner system was put out, the circulating water heater of recovering condensing heat was tested and the results were analyzed.

  6. A review on test procedure, energy efficiency standards and energy labels for room air conditioners and refrigerator-freezers

    Energy Technology Data Exchange (ETDEWEB)

    Mahlia, T.M.I.; Saidur, R. [Department of Mechanical Engineering, University of Malaya, 50603 Kuala Lumpur (Malaysia)

    2010-09-15

    Air conditioners and refrigerator-freezers are major energy users in a household environment and hence efficiency improvement of these appliances can be considered as an important step to reduce their energy consumption along with environmental pollution prevention. Energy efficiency standards and labels are commonly used tools to reduce the energy uses for household appliances for many countries around the world. The first step towards adopting energy efficiency standards is to establish a test procedure for rating and testing of an appliance. It may be mentioned that an energy test procedure is the technical foundation for energy efficiency standards, energy labels, and other related programs. This paper reviews requirements and specifications of various international test standards for testing and rating of room air conditioners and refrigerators. A review on the development of the energy efficiency standards has been provided as well. Finally, energy labels that provide some useful information for identifying energy efficient products have been reviewed for these appliances. It may be stated that the review will be useful for the developing countries who wish to develop these energy savings strategies. It is also expected to be useful to revise the existing strategies for a few selected countries who already implemented these strategies earlier. (author)

  7. The design of the motor bracket for reduction of structure-borne noise in package air-conditioner

    Energy Technology Data Exchange (ETDEWEB)

    Sim, Hyoun Jin; Lee, Sung Jin; Oh, Jae Eung [Hanyang University, Seoul (Korea, Republic of); Kang, Tae Ho [WiniaMando, Asan (Korea, Republic of); Lee, Jung Yoon [Kyonggi University, Suwon (Korea, Republic of)

    2006-02-15

    As the economic power is improved and the customer's demand is hard to please, the noise and vibration is the most important yardstick that can determine the quality of the product. Especially, as the air-conditioner's demand increase suddenly, the product of quality and the noise is becoming a decisive factor of determining whether purchase the product or not. Therefore, every manufactory is investing a lot of money and research to cut down the unpleasantness induced from noise and vibration. And they are emphasizing their product's difference by advertising a silence very actively. With these reason, the demand of a silent indoor air-conditioner is the essential research filed when the product is developed. In this study, the noise and vibration is visualized in the space and frequency domain by using experimental methods such as Operational Deflection Shape (ODS), modal testing and sound intensity. Also the location of noise source and its characteristic is analyzed in an acoustical point of view to reduce the structure borne noise that come from the fan motor, and the pertinent control method is suggested. Furthermore, the most suitable shape of the motor bracket is suggested by applying FEM and DOE (Design of Experiments) in the noise and vibration point a view.

  8. Performance of a prototype micro wind turbine in the manmade wind field from air conditioner of buildings

    Directory of Open Access Journals (Sweden)

    K. H. Goh

    2012-03-01

    Full Text Available Harnessing waste energy from the manmade air fields of buildings presents a new area of renewable energy to explore. Due to the unpredictability of the natural wind, this study is to evaluate the practicality for harnessing waste energy from the air conditioner exhaust units which are a more constant and predictable source available in the buildings. A prototype of the micro wind turbine has been designed to minimize the negative effect of the exhaust sources. After the micro wind turbine was manufactured, the performance of the turbine was tested in the selected air conditioner exhaust unit. Increasing the rotor solidity and decreasing the resistance of the generator contribute to improved starting torque and decreased generator break in torque respectively in the design. The power generation of the micro wind turbine increases with an increase of the rotor speed. The 24-hour operation of the prototype presents an observation for both exhaust performance and power generation prediction when the prototype is mounted on the exhaust unit.

  9. Optimal Design Principle for Air Conditioner with Refrigerant R290%R290空调器的优化设计原则

    Institute of Scientific and Technical Information of China (English)

    高晶丹; 丁国良; 王婷婷; 高屹峰; 宋吉

    2013-01-01

    The principle for optimal design for air conditioners with refrigerant R290 is proposed. The principle is based on the thermal performance analysis and comparison of the three refrigerants, which are R290, R22 and R410A. The principle includes the optimal design of compressor, condenser, evaporator and orifice set: the compressor discharge rate of R290 air conditioner should be bigger; the condenser of R290 air conditioner can adopt heat exchangers with smaller diameter tubes; the evaporator of R290 air conditioner can adopt heat exchangers with smaller diameter tubes;the capillary length of R290 air conditioner should be about 39%longer than that of R22 air conditioner, and should be about 44%shorter than that of R410A air conditioner. Meanwhile, the suggestion of how to guarantee the security of R290 air conditioner is also proposed in this paper.%  在分析比较 R290、R22、R410A 三种工质热力性能的基础上,对采用 R290工质的空调器提出了优化设计原则。优化设计原则主要针对压缩机、冷凝器、蒸发器、节流装置四大部件:R290空调器的压缩机应增加排量;R290空调器的冷凝器可采用小管径换热器;R290空调器的蒸发器可采用小管径换热器;R290空调器的毛细管应比R22空调器的长约39%,比R410A空调器的短约44%。在提出R290空调器优化设计原则的同时,本文对保证R290空调器安全性提出了建议。

  10. 常规空调器用于低温制冷研究%Study on Low Temperature Refrigeration with Conventional Air Conditioner

    Institute of Scientific and Technical Information of China (English)

    孙静; 时红臣

    2015-01-01

    对常规空调器用于低温制冷进行了研究,通过控制系统改造实现了系统在低温下稳定运行,控制系统改造方案可以实现常规空调机组低温制冷功能。%n this paper, how to achieve low temperatur air conditioning with conventional air conditioner were studied, through the control system renovation, air conditioning system run stably at low temperatur , the control system renovation scheme can realize the low temperature refrigeration function of conventional air conditioner.

  11. Natural refrigerants for air conditioners in passenger cars. A contribution to climate protection. Background; Natuerliche Kaeltemittel fuer PKW-Klimaanlagen. Ein Beitrag zum Klimaschutz. Hintergrund

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, Gabriele; Plehn, Wolfgang

    2010-09-15

    Air conditioners in passenger cars contain a refrigerant which significantly increases the greenhouse effect. Currently about 30 % of global emissions of partially fluorinated hydrocarbons originate from these air conditioners. According to the directive 2006/40/EC, this refrigerant must be replaced by a less harmful substance. Under this aspect, the contribution under consideration initially reports on the stock and level of air conditioning of passenger cars as well as on the refrigerant tetrafluoroethane. Subsequently, refrigerants for air conditioning of passenger cars such as carbon dioxide, 1.1-difluoroethane and 2,3,3,3-tetrafluoro propylene are described. Overall, the refrigerant carbon dioxide is the best alternative for mobile air conditioning.

  12. Microbiota fúngica dos condicionadores de ar nas unidades de terapia intensiva de Teresina, PI Fungus microbiota in air conditioners in intensive care units in Teresina, Piauí

    Directory of Open Access Journals (Sweden)

    Mitra Mobin

    2006-12-01

    Full Text Available Com intuito de identificar a microbiota fúngica em condicionadores de ar nas unidades de terapia intensiva de hospitais públicos e particulares de Teresina-PI, coletou-se material sólido de dez UTIs, isolando 33 espécies pertencentes às Moniliaceae e Dematiaceae, sendo primeira referência para o Piauí. Registrou-se elevada freqüência de Aspergillus niger Van Tieghem (60%; Aspergillus fumigatus Fres (50%; Trichoderma koningii Oudem (50%, Aspergillus flavus Link: Fr (40%. A validade da limpeza dos condicionadores de ar ultrapassou em todas as UTIs, a quantidade de unidades formadoras de colônia estava além do permitido pela Portaria 176/00 do Ministério da Saúde. É importante que os profissionais estejam munidos de equipamento de proteção individual, além de adotar medidas de controle de infecção hospitalar, sensibilizar para a existência de infecções fúngicas, melhorar ventilação de ar, possibilitando arejamento do ambiente e limpar periodicamente os condicionadores de ar, conscientizando os profissionais de saúde da importância destes fungos no ambiente hospitalar.With the aim of identifying the fungus microbiota in air conditioners in intensive care units (ICUs within public and private hospitals in Teresina, Piauí, solid material was collected from ten different ICUs. Thirty-three species of Moniliaceae and Dematiaceae were isolated, which was the first report of these in Piauí. High frequencies of Aspergillus niger Van Tieghem (60%, Aspergillus fumigatus Fres (50%, Trichoderma koningii Oudem (50% and Aspergillus flavus Link: Fr. (40% were recorded. The air conditioner cleanliness validity had expired in all the ICUs, and the quantity of colony-forming units exceeded the levels permitted by Law 176/00 from the Ministry of Health. It is important to provide individual protection equipment for professionals, adopt hospital infection control measures, raise the awareness of the presence of fungus infection, improve

  13. Adoption of the Energy-saving Technology of Central Air Conditioner in Modern Hospital%现代医院中央空调节能技术的应用

    Institute of Scientific and Technical Information of China (English)

    鲁晶; 彭承琳; 牟帮易

    2012-01-01

      能源是当今世界性的迫切问题,提高空调的制冷效果对于节约能源和减少医院的运营成本,都具有十分重要的意义。鉴于当前节能环保、全球气候异常等问题,本文对医院中央空调系统如何“节能”问题进行了论述。目前利用废热、余热作为能源的溴化锂吸收式冷水机组越来越受到关注。本文对溴化锂吸收式冷水机组的新技术及应用也进行了介绍,并作了中央空调系统关于节能的几个方面的比较。%  Energy is the most urgent problem in the world. To improve the cooling efficiency of air conditioner plays an important role in saving energy and cost control of hospital operations. As the environmental issues and global climate changes have drawn the concern of governments and people worldwide at present time, this article elaborates energy saving of central air conditioner system in hospital. LiBr absorption chil ers which use the waste heat as the power source are get ing more and more popular today. Some new technologies and applications of LiBr absorption Chil er are also discussed in the article. Energy saving of the central air conditioning system are analyzed and compared in some aspects at the same time.

  14. 中央空调节能技术分析%On technical analysis of central air-conditioner for saving energy

    Institute of Scientific and Technical Information of China (English)

    董云龙

    2009-01-01

    From three aspects of the air-conditioner design, the control in key links, the energy-saving measures in using process and the management of the central air-conditioner, the paper analyzes and sums up the energy-saving of the central air-conditioner system and provides opinions for the energy-saving of the central air-conditioner system, so as to enhance the devdopment of the architectural energy-saving and the creation of the conservation-mined society.%从空调设计中的关键环节控制、空调使用过程中的节能措施以及中央空调的管理三个方面,对中央空调系统的节能进行了分析和总结,为中央空调系统的节能提供了有意义的看法,以促进建筑节能的发展和节约型社会的创建.

  15. Fire cause investigation of a air conditioner fault fire%对一起空调器故障引发火灾的原因分析

    Institute of Scientific and Technical Information of China (English)

    于深源

    2012-01-01

    介绍了一起空调器故障引发火灾的现场勘查认定.在未能发现空调器是否发生过故障的情况下,根据空调室内机内及室内部分冷媒管线聚氨酯保温护套的异常痕迹,证明了空调器异常运行、冷媒管异常发热的情况,并结合中国科学院沈阳金属研究所鉴定结论,正确认定了火灾原因.%Fire scene renaissance of a air conditioner fault fire was analyzed. In the event that air conditioner failure could' t be identified, based on abnormal traces of air conditioner indoor unit and some indoor refrigerant pipeline polyurethane insulation sheath, it was proved that the air conditioner didn't run properly and the refrigerant pipe heated abnormally. Combined with identification of Institute of Metal Research, Chinese A-cademy of Sciences, fire cause was identified.

  16. Effect of deflecting ring on noise generated by outdoor set of a split-unit air conditioner

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Junwei; Ding, Guoliang [Institute of Refrigeration and Cryogenics, Shanghai JiaoTong University, Shanghai 200030 (China)

    2006-05-15

    In order to analyze the influence of the deflecting ring on the noise generated by the outdoor set of a split-unit air conditioner, the flow field in the outdoor set is simulated with the CFD software STAR-CD, the relative turbulent intensities are computed and the influence of the width and contoured duct of the deflecting ring on the noise generated by the outdoor set is analyzed. The results of computation and experiment show that there is an optimal width of the deflecting ring, corresponding to the minimum noise generated by the outdoor set. In addition, the influence of the contoured duct of the deflecting ring on the noise generated by the outdoor set is analyzed and a double contoured duct is designed. The results of computation and experiment verify that the deflecting ring with double contoured duct can improve the aerodynamic performance and reduce the noise generated by the outdoor set. (author)

  17. 提高空调产品性能研究%The Research of Improve the Air-conditioner Performance

    Institute of Scientific and Technical Information of China (English)

    2012-01-01

      本研究通过对家用空调结构优化设计,提高内机循环风量,以及对蒸发器结构优化,输入输出管采用多进多出管,使制冷剂流入、流出均匀,大大提高空调制冷能力和能效。%Using the optimized design for the structure of air conditioner can improve the circulating air flow of indoor unit. Optimizing the structure of the evaporator, and using multiple-out tube for input & output pipe can make the inflow & outflow of refrigerant uniform, which greatly improves product’s ability and energy efficiency.

  18. Performance of mixture refrigerant R152a/R125/R32 in domestic air-conditioner

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Jiangtao; Chu, Yingjie; Hu, Jing; Liu, Zhigang [State Key Laboratory of Multiphase Flow in Power Engineering, Xi' an Jiaotong University, Xi' an, Shaanxi 710049 (China)

    2009-08-15

    This work reports a ternary blend R152a/R125/R32 with a mass ratio of 48/18/34 as a potential alternative to R22. A computer code has been developed with NIST REFPROP 7.0 for the comparative analysis of thermophysical properties and refrigerant performance of this new mixture and of R22. A drop-in test of this new mixture was performed in a domestic air-conditioner originally designed for R22. Both the calculation and experimental results showed that this new mixture could be regarded as a most likely drop-in substitute for R22 in many applications. The flammability of this ternary blend was also studied with an explosion apparatus to prove that it could be used safely. Besides, simulation of the refrigerant cycle leakage showed that the variation of composition due to leakage was so little that there is no much performance degradation. (author)

  19. Comparative analysis of thermal storage cooling and storage battery cooling using photovoltaic generation. Part 2. Research on architectural systematization of energy conversion devices; Taiyoko hatsuden ni yoru chikunetsu reibo to chikuden reibo ni tsuite. 2. Energy henkan no kenchiku system ka ni kansuru kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Ito, N.; Kimura, G.; Fukao, S.; Shimizu, T.; Sunaga, N.; Tsunoda, M.; Muro, K.; Yamanaka, S. [Tokyo Metropolitan University, Tokyo (Japan)

    1996-10-27

    For use in energy self-sufficient buildings, a system was studied capable of retaining for its own use the excess of power produced by a photovoltaic power generation system without releasing it to the commercial system. Summertime cooling was considered. The storage battery cooling system was provided with two solar cell systems and, in the daytime, one was used for cooling and the other for charging batteries for nighttime cooling. In the cold heat storage cooling system, cold heat accumulators (red bricks) were provided in the wall and floor, and under the floor, and the floor was a grating for proper ventilation between the room and underfloor space. With the solar cell-driven air conditioner out of operation, cold heat was fed to the room from the underfloor cold heat accumulators by a fan. In storage battery cooling, solar power covered 60% of what the air conditioner used. In the presence of sufficient power in storage, the air conditioner stayed on at night without buying commercial power, when the room temperature was 25{degree}C. In the cold heat accumulation cooling, 50% of the air conditioner power consumption was covered by solar power. It is recommended to install cold heat accumulators not in the room but in a separate space, such as the underfloor space, where they are exposed to the cooling cold air direct from an air conditioner for future retrieval of cold heat. 2 refs., 9 figs., 3 tabs.

  20. 空调器使用陋习及其解决方案分析%Analysis of the Bad Habits in Use of Air Conditioner and Solutions

    Institute of Scientific and Technical Information of China (English)

    朱王武; 余志强; 陈志; 邹文才; 潘卢义; 徐名艳

    2015-01-01

    After the observation of the air conditioner usage, it found many bad habits in use, such as, overuse of air conditioners, turned air conditioners without person, and so on. These bad habits cause the unnecessary energy waste of air conditioner. For this, this paper proposed an energy-saving control device which is based on the outdoor temperature, indoor staff conditions and time mode, can correct the bad habits, and is suitable for small air conditioner. Application of the device can reduce unnecessary energy and labor costs, improve management efficiency, and also can bring good economic benefits to the family and unit, and it has positive significance for the energy conservation and emission reduction of society.%经过对空调器使用习惯的观察发现,普遍存在着空调器过度使用、无人却开机等多种的使用不良习惯。这些习惯造成了空调器不必要的能源浪费。对此,提出一种基于室外气温、室内人员情况和时间模式的、可纠正不良使用习惯的、面向小型空调器的节能控制装置。该装置的应用能减少不必要的能源和人工开支,提高管理效率,给单位和家庭还可带来不错的经济效益,对整个社会的节能减排具有积极意义。

  1. Experimental investigation of HFC407C/HC290/HC600a mixture in a window air conditioner

    Energy Technology Data Exchange (ETDEWEB)

    Jabaraj, D.B.; Avinash, P.; Lal, D. Mohan; Renganarayan, S. [Department of Mechanical Engineering, College of Engineering, Anna University, Chennai 600 025 (India)

    2006-09-15

    HCFC22, one of the widely used refrigerants in window air conditioners must be phased out soon as per the Montreal protocol. Presently, HFC407C is considered as a potential drop in substitute for HCFC22, but retrofitting HCFC22 systems with HFC407C with polyol ester oil (POE) is a major issue as HFC407C is immiscible with mineral oil. The miscibility issue of HFC407C with mineral oil was overcome with the addition of a HC blend to it. The above technoeconomic feasibility issues to retrofit the existing HCFC22 systems with an ozone friendly refrigerant and retain the energy efficiency of the system are challenges in the air conditioning sector. In this present work, an experimental analysis has been conducted in a window air conditioner retrofitted with eco-friendly refrigerant mixtures of HFC407C/HC290/HC600a without changing the mineral oil. Its performance, as well as energy consumption, was compared with the conventional one. It is observed that the mixtures demand lengthening of the condenser in order to maintain the discharge pressure within acceptable limits. This also resulted in better heat transfer at the condenser. Therefore, in this study, the condenser tube length was increased by 19% to suit the mixtures as compared to HCFC22. Compared to HCFC22, the refrigeration capacity of the new mixture was 9.54-12.76% higher than that of HCFC22, while the actual COP was found to be 11.91-13.24% higher than that of HCFC22. The overall performance has proved that the HFC407C/HC blend refrigerant mixture could be an eco-friendly substitute to phase out HCFC22. (author)

  2. AN EXPERIMENTAL ANALYSIS OF THE EFFECT OF REFRIGERANT CHARGE LEVEL AND OUTDOOR CONDITION ON A WINDOW AIR CONDITIONER

    Directory of Open Access Journals (Sweden)

    M Herbert Raj

    2010-01-01

    Full Text Available R22 is an hydrochlorofluorocarbon widely used in refrigerant and air conditioning plants and although it has a low ozone depletion potential (0.05, it is necessary to consider the large amount that commonly escapes from commercial units to the atmosphere. This paper presents experimental investigation on the performance of a window air conditioner operated with R22 and the M20 (80% R407C and 20% HC blend by wt. refrigerant mixture tested under different refrigerant charge levels and outdoor conditions. Experiments were conducted in accordance with the Bureau of Indian standards procedure in a psychrometric test facility. Capillary and charge optimization tests were conducted for the both R22 and the M20 refrigerant mixture based on maximum coefficient of performance. Refrigerant charge in the air conditioner was systematically varied and the influences of refrigerant charge quantities and outdoor conditions on system performance are studied for both R22 and the M20 refrigerant mixture. At each charge levels, the outdoor room conditions were changed in accordance with Bureau of Indian standards. It is observed that R22 is more sensitive to deviations in charge levels as compared to the M20 refrigerant mixture. A decrease in charge level of about 7% reduced the system refrigerating capacity by 11.3% with R22 while with the M20 refrigerant mixture it reduces by 6.9% only. Similarly an over charge by 7% reduces the refrigerating capacity of the system by 13.8% with R22 while with M20 it reduces by 6.5% only.

  3. Influence of surrounding structures upon the aerodynamic and acoustic performance of the outdoor unit of a split air-conditioner

    Science.gov (United States)

    Wu, Chengjun; Liu, Jiang; Pan, Jie

    2014-07-01

    DC-inverter split air-conditioner is widely used in Chinese homes as a result of its high-efficiency and energy-saving. Recently, the researches on its outdoor unit have focused on the influence of surrounding structures upon the aerodynamic and acoustic performance, however they are only limited to the influence of a few parameters on the performance, and practical design of the unit requires more detailed parametric analysis. Three-dimensional computational fluid dynamics(CFD) and computational aerodynamic acoustics(CAA) simulation based on FLUENT solver is used to study the influence of surrounding structures upon the aforementioned properties of the unit. The flow rate and sound pressure level are predicted for different rotating speed, and agree well with the experimental results. The parametric influence of three main surrounding structures(i.e. the heat sink, the bell-mouth type shroud and the outlet grille) upon the aerodynamic performance of the unit is analyzed thoroughly. The results demonstrate that the tip vortex plays a major role in the flow fields near the blade tip and has a great effect on the flow field of the unit. The inlet ring's size and throat's depth of the bell-mouth type shroud, and the through-flow area and configuration of upwind and downwind sections of the outlet grille are the most important factors that affect the aerodynamic performance of the unit. Furthermore, two improved schemes against the existing prototype of the unit are developed, which both can significantly increase the flow rate more than 6 %(i.e. 100 m3·h-1) at given rotating speeds. The inevitable increase of flow noise level when flow rate is increased and the advantage of keeping a lower rotating speed are also discussed. The presented work could be a useful guideline in designing the aerodynamic and acoustic performance of the split air-conditioner in engineering practice.

  4. A fundamentally new approach to air-cooled heat exchangers.

    Energy Technology Data Exchange (ETDEWEB)

    Koplow, Jeffrey P.

    2010-01-01

    We describe breakthrough results obtained in a feasibility study of a fundamentally new architecture for air-cooled heat exchangers. A longstanding but largely unrealized opportunity in energy efficiency concerns the performance of air-cooled heat exchangers used in air conditioners, heat pumps, and refrigeration equipment. In the case of residential air conditioners, for example, the typical performance of the air cooled heat exchangers used for condensers and evaporators is at best marginal from the standpoint the of achieving maximum the possible coefficient of performance (COP). If by some means it were possible to reduce the thermal resistance of these heat exchangers to a negligible level, a typical energy savings of order 30% could be immediately realized. It has long been known that a several-fold increase in heat exchanger size, in conjunction with the use of much higher volumetric flow rates, provides a straight-forward path to this goal but is not practical from the standpoint of real world applications. The tension in the market place between the need for energy efficiency and logistical considerations such as equipment size, cost and operating noise has resulted in a compromise that is far from ideal. This is the reason that a typical residential air conditioner exhibits significant sensitivity to reductions in fan speed and/or fouling of the heat exchanger surface. The prevailing wisdom is that little can be done to improve this situation; the 'fan-plus-finned-heat-sink' heat exchanger architecture used throughout the energy sector represents an extremely mature technology for which there is little opportunity for further optimization. But the fact remains that conventional fan-plus-finned-heat-sink technology simply doesn't work that well. Their primary physical limitation to performance (i.e. low thermal resistance) is the boundary layer of motionless air that adheres to and envelops all surfaces of the heat exchanger. Within this

  5. 无人值守基站空调室外机防盗方案探讨%Discussion of Guard Against Theft for Outdoor Air Conditioner in Unattended Base Station

    Institute of Scientific and Technical Information of China (English)

    闫保辉

    2011-01-01

    Outdoor air conditioners are missing seriously from unattended base station.In this paper,the discussion of guard against theft is given from the following aspects: installation of outdoor air conditioner,report of alarms,and accurate location of GPS terminal to lost outdoor air conditioner.%无人值守基站空调室外机丢失严重。文中从室外机安装,告警上报,GPS定位终端对丢失的室外机精确定位几方面提出了一种空调室外机防盗方案。

  6. 10 CFR 434.517 - HVAC systems and equipment.

    Science.gov (United States)

    2010-01-01

    ... zone Packaged terminal air conditioner with space heater or heat pump, one heating/cooling unit per... conditioner w/space heater (Note 8) Hot water (Note 8, 12) Hot water (Note 12) or electric resistance (Note B... and Reference Buildings 1,2 Building/space occupancy System No. (Table 517.4.1) Remarks (Table 517.4.1...

  7. VRF air conditioner connected to the central control system. LON interface in the Sparkasse Greiz administrative building; Einsatz einer VRF-Klimaanlage mit Anbindung an die GLT. Ermoeglicht in der Sparkasse Greiz durch LON-Schnittstelle

    Energy Technology Data Exchange (ETDEWEB)

    Loescher, L. [Mitsubishi Electric Europe B.V., Dresden (Germany)

    2007-07-15

    Central monitoring and control systems ensure automatic control and optimum operating conditions of heating systems, air conditioners and ventilation systems. The operating cost is minimized by early intervention. (orig.)

  8. Autonomous solar air conditioner. 100 percent solar powered; Solar autarke Klimatisierung. Mit 100% Sonnenenergie

    Energy Technology Data Exchange (ETDEWEB)

    Hindenburg, C. [Fraunhofer ISE, Freiburg (Germany)

    2004-11-01

    Autonomous solar cooling is an interesting option in all cases where storage of chilled products brings about large inherent thermal (cold) storage potential, e.g. wine production. There are also applications in air conditioning of buildings in which autonomous solar cooling systems are technically feasible and economically interesting. (orig.) [German] Generell sind alle Faelle von Prozesskuehlung, in denen durch die Lagerung von gekuehlten Produkten prozessinhaerent grosse thermische (Kaelte-)Speicher vorhanden sind, fuer die solar autarke Kuehlung interessant, beispielsweise die Weinherstellung. Es gibt aber auch Anwendungsfaelle im Bereich der Gebaeudeklimatisierung, bei denen eine solar autarke Kuehlung technisch machbar und zugleich oekonomisch darstellbar ist. (orig.)

  9. Improving Best Air Conditioner Efficiency by 20-30% through a High Efficiency Fan and Diffuser Stage Coupled with an Evaporative Condenser Pre-Cooler

    Energy Technology Data Exchange (ETDEWEB)

    Parker, Danny S; Sherwin, John R; Raustad, Richard

    2014-04-10

    The Florida Solar Energy Center (FSEC) conducted a research project to improve the best residential air conditioner condenser technology currently available on the market by retrofitting a commercially-available unit with both a high efficiency fan system and an evaporative pre-cooler. The objective was to integrate these two concepts to achieve an ultra-efficient residential air conditioner design. The project produced a working prototype that was 30% more efficient compared to the best currently-available technologies; the peak the energy efficiency ratio (EER) was improved by 41%. Efficiency at the Air-Conditioning and Refrigeration Institute (ARI) standard B-condition which is used to estimate seasonal energy efficiency ratio (SEER), was raised from a nominal 21 Btu/Wh to 32 Btu/Wh.

  10. Electrical and Control System Air Conditioner Teaching%空调器电气与控制系统教学的思考

    Institute of Scientific and Technical Information of China (English)

    吴雷; 阳丽

    2013-01-01

    空调器电气与控制系统部分是整个空调器教学中十分重要的内容,作者通过理论与实践教学,发现了当下在空调器教学中遇到的问题,并反思总结了一些有意义的经验做法。%Conditioner electrical and control parts of the system is the air conditioner is very important teaching content through the theory and practice of teaching, found a moment in the air conditioner problems encountered in teaching and reflect summa-rizes some meaningful experience approach.

  11. 谈暖通空调节能问题%On energy-saving issues in heat-supply and ventilation air-conditioners

    Institute of Scientific and Technical Information of China (English)

    张志宇

    2016-01-01

    The paper introduces the meanings in the energy-saving design of heat-supply and ventilation air-conditioners,illustrates the design methods from the heat-supply,ventilation and air-conditioners,and sums up the precautions in the energy-saving design,so as to improve the u-tility ratio of the resources and enhance the extension of the energy-saving technique.%介绍了暖通空调节能设计的意义,从供暖、通风、空调三方面,阐述了暖通空调节能设计的方法,总结了节能设计中的注意事项,有利于提高能源的利用率,促进节能技术的推广应用。

  12. Study on breeding of acaroid mites in room air conditioners in Wuhu, China%芜湖地区居室空调粉螨污染研究

    Institute of Scientific and Technical Information of China (English)

    湛孝东; 陈琪; 郭伟; 李朝品

    2013-01-01

    目的 了解芜湖地区居室内空调粉螨的污染情况.方法 于2012年6-10月采集芜湖市居民家用柜式空调和壁挂式空调隔尘网的灰尘,对孳生的螨类进行分类鉴定,并按种统计个体数.率的比较采用x2检验.结果 共收集202份空调隔尘网积尘样本,检出螨类3265只,其中粉螨2796只,隶属6科14属18种;平均孳生密度为10.39只/g,孳生率为70.79%;柜式空调隔尘网积尘中螨类孳生率为58.73%,壁挂式空调螨类孳生率为76.26%,二者差异有统计学意义(x2=6.442,P<0.05).麦食螨科、粉螨科和食甜螨科构成比较高,分别为53.47%、20.96%和18.13%.结论 芜湖地区柜式空调和壁挂式空调隔尘网粉螨孳生情况严重,物种多样性丰富.%Objective To investigate the breeding of acaroid mites in room air conditioners in Wuhu,China.Methods Dust was collected from the dust screens of the cabinet air conditioners and wall-mounted air conditioners used by Wuhu residents from June to October 2012.The mites breeding in the dust were classified and identified,and the mites of each species were counted.The mite breeding rates were compared by chi-square test.Results A total of 202 dust samples were collected from the dust screens of air conditioners; 3265 mites,including 2796 acaroid mites,were detected from the dust samples,and they were identified as 18 species,14 genera,and 6 families.The mean breeding density was 10.39 mites/g of dust,and the breeding rate was 70.79%.The mite breeding rate for the cabinet air conditioners was 58.73%,versus 76.26% for the wall-mounted air conditioners (x2=6.442,P<0.05).Pyroglyphidae,Acaridae,and Glycyphagidae were commonly seen and accounted for 53.47%,20.96%,and 18.13% of the total tmites,respectively.Conclusion In Wuhu,acaroid mites breed heavily in the dust screens of cabinet air conditioners and wall-mounted air conditioners,with high species diversity.

  13. Development and Application of Air Conditioner with Energy-saving Condensate Water Nebulization for Vehicle%车载冷凝雾化节能空调的开发与应用

    Institute of Scientific and Technical Information of China (English)

    卢建萍

    2011-01-01

    The author introduces a new type of auto air-conditioner, which has marked energy-saving effect through condensation water nebulization. This auto air-conditioner could be widely applied.%介绍一种带冷凝水雾化装置的新型空调系统。该系统具有明显的节能降耗效果,应用前景广泛。

  14. Strict Implementation of Air-Conditioner Temperature Control Standards to Actively Help Public Building Energy Saving%严格执行空调温控标准积极助力公共建筑节能

    Institute of Scientific and Technical Information of China (English)

    上海市节能监察中心

    2015-01-01

    简要介绍了2015年空调温控监察工作,提出了存在的主要问题、解决方法及今后空调温控监察的打算和建议.%The article introduces air-conditioner temperature control supervision work and puts forward existing problems, solutions and plans and suggestions on air-conditioner temperature control supervision in the future.

  15. 蓄能空调技术及其发展%The Technology and Development of Energy-storage Air-conditioners

    Institute of Scientific and Technical Information of China (English)

    叶水泉

    2002-01-01

    In this article importance of using energy storage technology in peak-clipping and valley-filling of the demandside management in our country' s power systems is generally discussed. With a practical application in projects, superiorityof the energy-storage air-conditioner is tested and proved. This article comprehensively presents some methods taken byadministration branches of domestic and international governments in supporting its application as well as its current appli-cation situation abroad.

  16. Alternative Refrigerant Evaluation for High-Ambient Temperature Environments: R-22 and R-410A Alternatives for Mini-Split Air Conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Abdelaziz, Omar [ORNL; Munk, Jeffrey D [ORNL; Shrestha, Som S [ORNL; Linkous, Randall Lee [ORNL; Goetzler, William [Navigant Consulting Inc.; Guernsey, Matt [Navigant Consulting Inc.; Kassuga, Theo [Navigant Consulting Inc.

    2015-08-01

    The Oak Ridge National Laboratory (ORNL) High-Ambient Temperature Testing Program for Low-GWP Refrigerants aims to develop an understanding of the performance of low-Global Warming Potential (low-GWP) alternatives to Hydrochlorofluorocarbon (HCFC) and Hydrofluorocarbon (HFC) refrigerants in mini-split air conditioners under high ambient temperature conditions. This interim working paper describes the parties involved, the alternative refrigerants selection process, the test procedures, and the preliminary results.

  17. Alternative Refrigerant Evaluation for High-Ambient-Temperature Environments: R-22 and R-410A Alternatives for Mini-Split Air Conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Abdelaziz, Omar [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Shrestha, Som S. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Munk, Jeffrey D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Linkous, Randall Lee [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Goetzler, William [Navigant Consulting Inc., Burlington, MA (United States); Guernsey, Matt [Navigant Consulting Inc., Burlington, MA (United States); Kassuga, Theo [Navigant Consulting Inc., Burlington, MA (United States)

    2015-10-01

    The Oak Ridge National Laboratory (ORNL) High-Ambient-Temperature Evaluation Program for low– global warming potential (Low-GWP) Refrigerants aims to develop an understanding of the performance of low-GWP alternative refrigerants to hydrochlorofluorocarbon (HCFC) and hydrofluorocarbon (HFC) refrigerants in mini-split air conditioners under high-ambient-temperature conditions. This final report describes the parties involved, the alternative refrigerant selection process, the test procedures, and the final results.

  18. Air cooler ducts. A simple kind of air conditioner; Luftkuehlschaechte. Eine einfache Teilklimaanlage

    Energy Technology Data Exchange (ETDEWEB)

    Glueck, B. [F und E TGA, Joessnitz (Germany); Westsaechsische Hochschule Zwickau (F.H.) (Germany)

    2005-07-01

    Air cooler duct cabinets are used increasingly for cooling and demoisturizing of room air and fresh air, sometimes also as auxiliary heating systems. They are more complex than conventional and have specific characteristics concerning construction, dimensioning, optimisation and control. A newly developed computer program enables pre-assessment of specific operational situations. (orig.)

  19. Accelerating Improvements in the Energy Efficiency of Room Air Conditioners (RACs) in India: Potential, Cost-Benefit, and Policies (Interim Assessment)

    Energy Technology Data Exchange (ETDEWEB)

    Abhyankar, Nikit [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Shah, Nihar [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Park, Won Young [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Phadke, Amol [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-06-01

    Falling AC prices, increasing incomes, increasing urbanization, and high cooling requirements due to hot climate are all driving increasing uptake of Room Air Conditioners (RACs) in the Indian market. Air conditioning already comprises 40-60% of summer peak load in large metropolitan Indian cities such as Delhi and is likely to contribute 150 GW to the peak demand in 2030. Standards and labeling policies have contributed to improving the efficiency of RACs in India by about 2.5% in the last 10 years (2.5% per year) while inflation adjusted RAC prices have continued to decline. In this paper, we assess the technical feasibility, cost-benefit, and required policy enhancements by further accelerating the efficiency improvement of RACs in India. We find that there are examples of significantly more accelerated improvements such as those in Japan and Korea where AC efficiency improved by more than 7% per year resulting in almost a doubling of energy efficiency in 7 to 10 years while inflation adjusted AC prices continued to decline. We find that the most efficient RAC sold on the Indian market is almost twice as efficient as the typical AC sold on the market and hence see no technology constraints in a similar acceleration of improvement of efficiency. If starting 2018, AC efficiency improves at a rate of 6% instead of 3%, 40-60 GW of peak load (equivalent to connected load of 5-6 billion LED bulbs), and over 75 TWh/yr (equivalent to 60 million consumers consuming 100 kWh/month) will be saved by 2030; total peak load reduction would be as high as 50 GW. The net present value (NPV) of the consumer benefit between 2018-2030 will range from Rs 18,000 Cr in the most conservative case (in which prices don’t continue to decline and increase based estimates of today’s cost of efficiency improvement) to 140,000 Cr in a more realistic case (in which prices are not affected by accelerated efficiency improvement as shown by historical experience). This benefit is achievable by

  20. Study on load levelling by means of the control of air conditioner operation; Kuchoki kado seigyo ni yoru fuka heijunka ni kansuru ichikosatsu

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, H. [Hiroshima University, Hiroshima (Japan); Sadakuni, S. [Japan Broadcasting Corp., Tokyo (Japan)

    1995-04-20

    The recent drastic increase in the number of air conditioners has caused sharp and narrow peaks in summer seasons due to the inherent temperature sensitive characteristics. The authors proposed to reduce the peak power demand by controlling air conditioner operations, verifying its effectiveness on peak demand clipping. However, the former study has shortcomings in that any qualitative treatment of room temperatures or pleasant feeling was not attempted and it did not provide a way of assessing peak demand clipping in a power system as a whole. In this paper, we shall first propose a new control method that can compromise pleasant feeling and reduction in power demand. Although air conditioners are used to pursue `pleasant feeling`, this contradicts to reduce power consumption and further more the concept of `pleasant feeling` is very vague. Hence, `Weber-Fechner`s law` is utilized to quantify the pleasant feeling which is treated as fuzzy quantity. Fuzzy co-ordination method is used to compromise power demand curtailment and pleasantness. In the second part of this paper, we shall propose an approach of assessing the amount of peak load clipping when the newly proposed control strategy is adopted in a real size power system: A decrease in the required generation capacity is estimated provided that the Loss of Load Probability (LOLP) is maintained at the same level before and after the application of the new control strategy. The reduction can be regarded as a dividend of load management. 5 refs., 9 figs., 5 tabs.

  1. Air- conditioner Energy Saving Renovation of Gaokai District IDC Telecom Room in Tangshan%IDC机房空调节能改造工程

    Institute of Scientific and Technical Information of China (English)

    刘婷婷; 田浩

    2011-01-01

    本文介绍了中国联通唐山分公司高开区IDC(互联网数据中心)机房空调的节能改造工程,根据改造后空调机组耗电量的实测数据,对节能型机房空调与普通型机房空调的能耗进行了对比,证实了改造后机房空调方案具有很好的节能效果,可为相似老旧通信机房的节能改造提供参考.%The air - conditioner energy saving renovation of Gaokai district IDC (Internet Data Center) telecom room of China Unicom Tangshan Branch was introduced in this paper. According to the measured power consumption of the air conditioning units after renovation, the energy consumption of energy - sav-ing telecom room air conditioners and common telecom room air conditioners were also compared in this paper. It was proved that the energy saving effect after renovation was extremely obvisus. This paper may be a reference for the energy saving renovation of similar old telecom rooms.

  2. Sub-cooled liquid nitrogen cryogenic system with neon turbo-refrigerator for HTS power equipment

    Science.gov (United States)

    Yoshida, S.; Hirai, H.; Nara, N.; Ozaki, S.; Hirokawa, M.; Eguchi, T.; Hayashi, H.; Iwakuma, M.; Shiohara, Y.

    2014-01-01

    We developed a prototype sub-cooled liquid nitrogen (LN) circulation system for HTS power equipment. The system consists of a neon turbo-Brayton refrigerator with a LN sub-cooler and LN circulation pump unit. The neon refrigerator has more than 2 kW cooling power at 65 K. The LN sub-cooler is a plate-fin type heat exchanger and is installed in a refrigerator cold box. In order to carry out the system performance tests, a dummy cryostat having an electric heater was set instead of a HTS power equipment. Sub-cooled LN is delivered into the sub-cooler by the LN circulation pump and cooled within it. After the sub-cooler, sub-cooled LN goes out from the cold box to the dummy cryostat, and comes back to the pump unit. The system can control an outlet sub-cooled LN temperature by adjusting refrigerator cooling power. The refrigerator cooling power is automatically controlled by the turbo-compressor rotational speed. In the performance tests, we increased an electric heater power from 200 W to 1300 W abruptly. We confirmed the temperature fluctuation was about ±1 K. We show the cryogenic system details and performance test results in this paper.

  3. Discussion the Term and Application of the Direct Evaporative Cooling in Ventilation Cooling%浅谈直接蒸发冷却通风降温术语及其应用

    Institute of Scientific and Technical Information of China (English)

    夏青; 黄翔; 殷清海

    2012-01-01

    With the development of national economy,more and more air conditioner applications.However,in our different regions and different places,in order to ensure the indoor temperature and humidity requirements,the need to adopt the situation of air conditioning systems are different.The article passes the interpretation of the terms for direct evaporative cooling in ventilation cooling,and thus studies the two terms of their correct expression and definitions of the two forms,and discusses the importance of air conditioner in ventilation cooling,also the standards about the direct evaporative cooling unit equipment briefly,it shows that in the heat of the large space as industrial workshop、high temperature workshop that the places produce a large amount of sensible heat is very economical.%通过诠释直接蒸发冷却通风降温术语,进而对两种系统形式术语的正确表达及其定义进行了探讨,并简单阐述了直接蒸发冷却通风降温的重要性以及单元式直接蒸发冷却设备相关标准,认为在以显热散热量为主的大空间工业厂房、高温车间等产生工艺余热的场所采用蒸发冷却技术是非常经济合理的。

  4. Cost-Benefit of Improving the Efficiency of Room Air Conditioners (Inverter and Fixed Speed) in India

    Energy Technology Data Exchange (ETDEWEB)

    Phadke, Amol [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Shah, Nihar [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Abhyankar, Nikit [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Park, Won Young [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Diddi, Saurabh [Bureau of Energy Efficiency, Government of India (India); Ahuja, Deepanshu [Collaborative Labeling and Appliance Standards Program (CLASP), Washington, DC (United States); Mukherjee, P. K. [Collaborative Labeling and Appliance Standards Program (CLASP), Washington, DC (United States); Walia, Archana [Collaborative Labeling and Appliance Standards Program (CLASP), Washington, DC (United States)

    2016-06-01

    Improving efficiency of air conditioners (ACs) typically involves improving the efficiency of various components such as compressors, heat exchangers, expansion valves, refrigerant,and fans. We estimate the incremental cost of improving the efficiency of room ACs based on the cost of improving the efficiency of its key components. Further, we estimate the retail price increase required to cover the cost of efficiency improvement, compare it with electricity bill savings, and calculate the payback period for consumers to recover the additional price of a more efficient AC. The finding that significant efficiency improvement is cost effective from a consumer perspective is robust over a wide range of assumptions. If we assume a 50% higher incremental price compared to our baseline estimate, the payback period for the efficiency level of 3.5 ISEER is 1.1 years. Given the findings of this study, establishing more stringent minimum efficiency performance criteria (one-star level) should be evaluated rigorously considering significant benefits to consumers, energy security, and environment

  5. Cost-Benefit of Improving the Efficiency of Room Air Conditioners (Inverter and Fixed Speed) in India

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Nihar [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Division; Abhyankar, Nikit [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Division; Park, Won Young [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Division; Phadke, Amol [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Division; Diddi, Saurabh [Government of India, New Delhi (India). Bureau of Energy Efficiency; Ahuja, Deepanshu [Collaborative Labeling and Appliance Standards Program (CLASP), Washington, DC (United States); Mukherjee, P. K. [Collaborative Labeling and Appliance Standards Program (CLASP), Washington, DC (United States); Walia, Archana [Collaborative Labeling and Appliance Standards Program (CLASP), Washington, DC (United States)

    2016-06-30

    Improving efficiency of air conditioners (ACs) typically involves improving the efficiency of various components such as compressors, heat exchangers, expansion valves, refrigerant and fans. We estimate the incremental cost of improving the efficiency of room ACs based on the cost of improving the efficiency of its key components. Further, we estimate the retail price increase required to cover the cost of efficiency improvement, compare it with electricity bill savings, and calculate the payback period for consumers to recover the additional price of a more efficient AC. We assess several efficiency levels, two of which are summarized below in the report. The finding that significant efficiency improvement is cost effective from a consumer perspective is robust over a wide range of assumptions. If we assume a 50% higher incremental price compared to our baseline estimate, the payback period for the efficiency level of 3.5 ISEER is 1.1 years. Given the findings of this study, establishing more stringent minimum efficiency performance criteria (one star level) should be evaluated rigorously considering significant benefits to consumers, energy security and environment.

  6. Performance of a new refrigeration cycle using refrigerant mixture R32/R134a for residential air-conditioner applications

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Jianyong; Yu, Jianlin [Department of Refrigeration and Cryogenic Engineering, School of Energy and Power Engineering, Xi' an Jiaotong University, Xi' an 710049 (China)

    2008-07-01

    In this paper, a new refrigeration cycle (NRC) using the binary non-azeotropic refrigerant mixture R32/R134a is presented, which can be an alternative refrigeration cycle applied in residential air-conditioner. In the NRC, refrigerant circuit of the evaporator is separated into two branches. Because the non-azeotropic mixture has the characteristic of temperature glide, an important benefit of such configuration is that the Lorentz cycle can be realized. Compared with that of conventional cycle configuration, the new cycle efficiency can be improved. The calculating results show that, in the conventional refrigeration cycle (CRC), the mixture R32/R134a has a close performance to that is obtainable with pure refrigerant R22. However, the mixture R32/R134a in the NRC will result in a better performance. The maximal COP can be improved in a range of 8-9% over that of the CRC, and the volumetric refrigerating capacity can be approximately increased by 9.5%. (author)

  7. Experimental investigation of using ambient energy to cool Internet Data Center with thermosyphon heat exchanger

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, F.; Tian, X.; Ma, G. [Beijing Univ. of Technology, Beijing (China). College of Environmental and Energy Engineering

    2010-07-01

    The energy consumption of the air-conditioning system at the Internet Data Center (IDC) in Beijing comprises 40 per cent of the building's total energy consumption. Of all the energy energy management strategies available at the IDC, the most unique one is the use of ambient energy to cool the IDC by the thermosyphon heat exchanger. Atmospheric energy can reduce the air conditioner's running time while maintaining the humidity and cleanliness of the IDC. In this study, an IDC test model was set up to analyze the heat dissipating characteristics and the energy consumption of the thermosyphon heat exchanger and the air conditioner in the IDC for winter conditions. The heat dissipating capacity of the building envelope was measured and calculated. The energy consumption of the air conditioner was compared under different indoor and outdoor temperatures. The study showed that the heat dissipating need of the IDC cannot be met just by the heat dissipation of the building envelope in winter conditions. The heat dissipating capacity of the IDC building envelope comprises 19.5 per cent of the total heat load. The average energy consumption of the air conditioner is 3.5 to 4 kWh per day. The temperature difference between indoor and outdoor temperature in the IDC with the thermosyphon heat exchanger was less than 20 degrees C, and the energy consumption of the thermosyphon heat exchanger comprised only 41 per cent of that of the air conditioner. 8 refs., 1 tab., 8 figs.

  8. Air Conditioner Selection with TOPSIS and VIKOR Methods In Multi Criteria Decision Making

    Directory of Open Access Journals (Sweden)

    İrfan ERTUĞRUL

    2014-06-01

    Full Text Available Technological and global changes nowadays enable air conditioning sector to gain a higher importance. Short and long term risks for comsumers, the use of air conditioningtechnology with cost minimization, the increase of product charesteristics and firms, and the variability of product features have led to the need for multi-criteria decision. Therefore, caring the multiple criteria and the alternatives, the multi-criteria decision making techniques are taken to the scope of application. The purpose of the study is to determine the factors which affect the decision of air conditioning choice and to present the preference ranking suggestion. Having the nearly have got the approximately equivalent heating and cooling capacity, air conditionings in A+ class are included in the scope of related research. In application, when choosing air conditioning products, Topsis and Vikor that are multi-criteria decision-making methods are used and the results are compared and evaluated. When choosing air conditioning products, preference plansa re presented in the application.

  9. High-Efficiency Variable Dehumidification for Air Conditioners: ClimaStat

    Energy Technology Data Exchange (ETDEWEB)

    West, Michael K., Ph.D. P.E.

    2006-04-30

    Advantek has successfully developed the first low-cost technology offering significant improvement in both Seasonal Energy Efficiency (SEER) and comfort & humidity control. A production prototype was constructed based on a commercial roof top package unit. The prototype was operated under a wide range of psychrometric conditions. Test data was analyzed to identify refinements, which were implemented to further improve performance in an iterative procedure that resulted in a fully optimized technology. The latest results show an increase in dehumidification capacity of 56% with ClimaStat™ in full dehumidify mode vs. with ClimaStat™ off. Dehumidification improved by a factor of 1.7 to 1.9 – meaning that the unit can provide nearly twice the water removal per unit of sensible cooling load. Performance testing results have been consistent, verifiable and repeatable. . ClimaStat™ cost-effectively controls humidity on-demand and improves indoor air quality while reducing annual energy costs. Test data clearly shows that ClimaStat™ costs 20% to 60% less to operate. ClimaStat™ is ready for market.

  10. Cooling system having dual suction port compressor

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Guolian

    2017-08-29

    A cooling system for appliances, air conditioners, and other spaces includes a compressor, and a condenser that receives refrigerant from the compressor. The system also includes an evaporator that receives refrigerant from the condenser. Refrigerant received from the condenser flows through an upstream portion of the evaporator. A first portion of the refrigerant flows to the compressor without passing through a downstream portion of the evaporator, and a second portion of the refrigerant from the upstream portion of the condenser flows through the downstream portion of the evaporator after passing through the upstream portion of the evaporator. The second portion of the refrigerant flows to the compressor after passing through the downstream portion of the evaporator. The refrigeration system may be configured to cool an appliance such as a refrigerator and/or freezer, or it may be utilized in air conditioners for buildings, motor vehicles, or other such spaces.

  11. 基于Matlab的CRH2动车组空调变频控制仿真%Simulation of Air Conditioner Frequency Conversion Control of CRH2 EMUs Based on Matlab

    Institute of Scientific and Technical Information of China (English)

    夏海龙; 杨美传; 刘峰

    2012-01-01

    介绍了CRH2动车组空调控制系统,并用Matlab/Simulink对动车组空调系统进行建模仿真,将空调变频控制系统与通断式空调控制系统二者作用下的客室温度和制冷量作比较分析,同时对过分相时动车组空调运行做了仿真.仿真模型能够较好地模拟动车组空调运行过程中客室温度和制冷量的变化.%Air conditioner control system of CRH2 EMUs was introduced and simulated based on Matlab/Simulink. Passenger room temperature and refrigerating output with frequency conversion control air conditioner system and on/off air conditioner control system was compared and analyzed, as well as air conditioner operation during train passing neutral sections was simulated. The built model simulates passenger room temperature and refrigerating output with air conditioner system well.

  12. Understanding the Dehumidification Performance of Air-Conditioning Equipment at Part-Load Conditions

    Energy Technology Data Exchange (ETDEWEB)

    Don B. Shirey III; Hugh I. Henderson Jr; Richard A. Raustad

    2006-01-01

    Air conditioner cooling coils typically provide both sensible cooling and moisture removal. Data from a limited number of field studies (Khattar et al. 1985; Henderson and Rengarajan 1996; Henderson 1998) have demonstrated that the moisture removal capacity of a cooling coil degrades at part-load conditions--especially when the supply fan operates continuously while the cooling coil cycles on and off. Degradation occurs because moisture that condenses on the coil surfaces during the cooling cycle evaporates back into air stream when the coil is off. This degradation affects the ability of cooling equipment to maintain proper indoor humidity levels and may negatively impact indoor air quality. This report summarizes the results of a comprehensive project to better understand and quantify the moisture removal (dehumidification) performance of cooling coils at part-load conditions. A review of the open literature was initially conducted to learn from previous research on this topic. Detailed performance measurements were then collected for eight cooling coils in a controlled laboratory setting to understand the impact of coil geometry and operating conditions on transient moisture condensation and evaporation by the coils. Measurements of cooling coil dehumidification performance and space humidity levels were also collected at seven field test sites. Finally, an existing engineering model to predict dehumidification performance degradation for single-stage cooling equipment at part-load conditions (Henderson and Rengarajan 1996) was enhanced to include a broader range of fan control strategies and an improved theoretical basis for modeling off-cycle moisture evaporation from cooling coils. The improved model was validated with the laboratory measurements, and this report provides guidance for users regarding proper model inputs. The model is suitable for use in computerized calculation procedures such as hourly or sub-hourly building energy simulation programs (e

  13. 77 FR 16769 - Energy Conservation Program for Certain Industrial Equipment: Energy Conservation Standards and...

    Science.gov (United States)

    2012-03-22

    ... provisions from Air- Conditioning, Heating, and Refrigeration Institute (AHRI) operations manuals in its test... ASHRAE equipment during a representative average use cycle. In addition, DOE must determine that the... procedure specifically tailored to computer room air conditioners, and confirmation that the basic model...

  14. Introduction of the New Edition of Air-conditioner Safety Standard%关于新版空调安全标准介绍

    Institute of Scientific and Technical Information of China (English)

    田磊

    2013-01-01

    This paper introduces the new major points of the air-conditioner standard GB 4706.32-2012, and points out the key points of changes of new standard, and briefly interprets the concept of software evaluation.%  本文介绍了新版空调标准GB 4706.32-2012的主要新增点,指出了关键性的变化点,对软件评估的概念做了简要解读。

  15. Plug-bit design of residential air conditioners Thinking%住宅外挂空调机位设计的思考

    Institute of Scientific and Technical Information of China (English)

    许群枫

    2011-01-01

    This paper investigates the existing exterior design of residential external air conditioners bit placement method,concludes its four possible seat designs,and further leads to thinking and looking forward to a better future.%对现行住宅外观设计上的外挂空调机位摆置方式进行了调查研究,总结其四种可行的机位设计,并进一步引出思考,展望美好的未来。

  16. 基于CAN总线的电动客车空调控制方案%Air-conditioner Control Project for Electric Bus Based on CAN Bus

    Institute of Scientific and Technical Information of China (English)

    杨桥生

    2012-01-01

    The author simply introduces two kinds of present control modes for air-conditioner of electric bus in domestic market,puts forward a new kind of its control mode based on CAN bus,and design the CAN's messages reports.%简述国内电动客车空调的两种控制模式;提出一种基于CAN总线的电动客车空调控制模式,并设计CAN通讯报文。

  17. Leakage Evaluation of Blend Refrigerant HCFC-22/HFC-152a for Auto mobile Air Conditioners%混合工质HCFC-22/HFC-152a汽车空调系统中泄漏性能分析

    Institute of Scientific and Technical Information of China (English)

    张华; 谷松

    2001-01-01

    A analysis of leakage is carried out for automobile air conditioner charged with HCFC-22/HFC-152a. The performance of automobile air conditioners doesn,t obvio usly change when leakage of the blend refrigerant happens. The HCFC-22/HFC-152a( 40/60mass%) can be used as alternative refrigerant in the transition period of e xisting automobile air conditioners.%对采用HCFC-22/HFC-152a混合制冷剂的汽车空调的 泄漏性能进行了分析;说明了HCFC-22/HFC-152a混合制冷剂不会因泄漏引起制冷系统性 能的显著变化,它可作为现有的汽车空调系统的过渡替代工质。

  18. New Test Requirement for Energy Efficiency of Air Conditioner for European Market%关于欧盟市场空调新能效的测试要求

    Institute of Scientific and Technical Information of China (English)

    臧松彦; 刘勃宏

    2013-01-01

      According to the new energy requirement for air conditioner performed from Jan. 1, 2013 and the newly-released European Standards (EN14825: 2012), the testing and calculation method of Seasonal Energy Efficiency Ratio (SEER) and Seasonal Coefficient of Performance (SCOP) of air conditioner was illustrated with inverter air-conditioner, and it could be taken for reference.%  本文根据欧盟2013年1月1日起执行生效的空调新的能源要求,以及最新发布的欧洲标准(EN14825:2012),以变频空调为例阐述空调季节能效比(SEER)和季节性能系数(SCOP)的测试计算方法,以供相关人员参考。

  19. 中央空调风系统管道清洗的调查探讨%On exploration for investigation of pipeline cleaning of central air-conditioner wind system

    Institute of Scientific and Technical Information of China (English)

    温嘉

    2012-01-01

    The study illustrates the necessity for the cleaning of the central air-conditioner system,introduces the development status and problems in the cleaning industry of the central pipeline air-conditioner system at home and abroad,and has the perspective for the future of the cleaning industry of the central air-conditioner system in China.%阐述了中央空调风系统清洗的必要性,介绍了国内外中央空调风系统管道清洗行业的发展状况和存在的问题,展望了我国中央空调风系统管道清洗行业发展的大好前景。

  20. On design for air-conditioners and ventilation in some orient home household square in Shanxi%山西某地东方家园家居广场的空调与通风设计

    Institute of Scientific and Technical Information of China (English)

    王业辉

    2012-01-01

    重点介绍了某家居广场的空调、通风的设计特点,阐述了空调方式、防排烟、空调自控及节能等的设计,强调了空调设计中节能的重要性及消防设计的重要性,以期引起相关设计人员重视。%The paper mainly introduces the design features for the air-conditioners and ventilation of the household square,mainly illustrates the design for the air-conditioning ways,the smoke control,the auto-control system of air-conditioners,and its energy-saving,and emphasizes the importance of the energy-saving and the fire-control design in the air-conditioner design,so as to draw the attention of relative design personnel.

  1. STUDY ON HOT SAND COOLING EQUIPMENT WITH DAMPING SAND CASCADE AND VERTICAL SPOUTED-FLUIDIZED BED

    Institute of Scientific and Technical Information of China (English)

    L.C. Wang; F. Wang; X.H. You

    2005-01-01

    A new kind of hot sand cooling equipment with vertical spouted-fluidized bed is developed in this paper. It is similar to the traditional horizontal vibrating fluidized boiling cooler in principle but different from it in structure. The processing principle of the cooler is analyzed. The influence of main structural and processing parameters on the cooling effect and its mechanism are researched. Other characteristics of the cooler are discussed also. Experiment results show that the cooling efficiency η is equal to or larger than 83%, the temperature of output sand is less than 40℃ with the temperature of input sand is about between 80 and 90℃, and the productivity is 5t/(h·m)

  2. Metal hydride air conditioner

    Institute of Scientific and Technical Information of China (English)

    YANG; Ke; DU; Ping; LU; Man-qi

    2005-01-01

    The relationship among the hydrogen storage properties, cycling characteristics and thermal parameters of the metal hydride air conditioning systems was investigated. Based on a new alloy selection model, three pairs of hydrogen storage alloys, LaNi4.4 Mn0.26 Al0.34 / La0.6 Nd0.4 Ni4.8 Mn0.2 Cu0. 1, LaNi4.61Mn0. 26 Al0.13/La0.6 Nd0.4 Ni4.8 Mn0.2 Cu0. 1 and LaNi4.61 Mn0.26 Al0.13/La0.6 Y0.4 Ni4.8 Mn0. 2, were selected as the working materials for the metal hydride air conditioning system. Studies on the factors affecting the COP of the system showed that higher COP and available hydrogen content need the proper operating temperature and cycling time,large hydrogen storage capacity, flat plateau and small hysterisis of hydrogen alloys, proper original input hydrogen content and mass ratio of the pair of alloys. It also needs small conditioning system was established by using LaNi4.61 Mn0.26 Al0. 13/La0.6 Y0.4 Ni4.8 Mn0.2 alloys as the working materials, which showed that under the operating temperature of 180℃/40℃, a low temperature of 13℃ was reached, with COP =0.38 and Wnet =0.09 kW/kg.

  3. 基于SINDA/FLUINT平台的R290房间空调器仿真%R290 room air- conditioner simulation based on SINDA/FLUINT

    Institute of Scientific and Technical Information of China (English)

    梁杰荣; 李廷勋

    2011-01-01

    R290 is environment -friendly natural refrigerant, but it is flammable. According to IEC 60335 the charge is limited strictly in room air conditioner (RAC). In this paper, simulating models of R290 room air conditioner were developed based on SINDA/FLUINT, and the models were verified by comparing the simulated temperature distribution and system performance like COP and indoor air humidity with experiment results. With the models, the R290 mass distribution and pressure drop among the RAC components were calculated. It is found that refrigerant concentrates in condenser (62%), while pressure drop is mainly produced in evaporator, liquid line and vapor line.%R290制冷剂是环保自然工质,但具有可燃性,在空调中对充注量要求非常严格.基于SINDA/FLUINT仿真平台对R290系统进行建模,通过与温度和运行性能的实验数据对比,检验了模型的可靠性;计算分析了R290空调器内各部件的制冷剂分布及沿程压损.计算结果表明,冷媒主要集中在冷凝器(62%);沿程压损主要集中在蒸发器,液相管和气相管.

  4. 某图书馆暖通空调系统设计分析%On heat-supply and ventilation air-conditioner system of some library

    Institute of Scientific and Technical Information of China (English)

    王秀山

    2016-01-01

    According to the design ideas for the library,from heat-supply and ventilation air-conditioner system,cold and heat source system,in-terior layout,professional cooperation and other aspects,the paper analyzes a series of problems in the heat-supply and ventilation air-conditioner of some library,and illustrates respective treatment measures,so as to create the comfortable reading environment with suitable temperature and humidity.%根据图书馆的设计理念,从暖通空调系统、冷热源系统、室内系统布置、专业配合等方面,分析了某图书馆暖通空调设计中存在的一系列问题,并阐述了相应的处理措施,旨在创造出温湿度适宜、环境清新的阅读环境.

  5. Specific characteristics of the R744 (CO2) air conditioner for compact cars; Besonderheiten der R744 (CO{sub 2}) Klimaanlagen fuer Kleinfahrzeuge

    Energy Technology Data Exchange (ETDEWEB)

    Kicherer, S.; Huenemoerder, W. [DENSO AUTOMOTIVE Deutschland GmbH, Eching (Germany)

    2005-07-01

    The European Union intends to ban halogenated fluorochlorocarbons (HCFC). Substitute refrigerants should have a global warming potential (GPW) of less than 150. The current refrigerant R134a has a GWP in the order of 1300 and will be banned. For the future, the German car industry is focusing on CO2 (carbon dioxide, R744). The advantages are a GWP of 1 (reference value for comparisons with H-CFC) and an excellent performance both in air conditioners and in combined air conditioners that can also serve as heat pumps. The cold generation capacity, however, is lower than with R134a in conditions of high ambient temperatures (above 35 ) and with the engine in idle operation, so that higher fuel consumption and slower acceleration may be a problem especially in compact vehicles with low rotary momentum. The specific characteristics of CO2 systems must therefore be taken into acount in car development in order to be able to optimize fuel consumption of the compressor. The contribution focuses on these characteristics and presents possible solutions. (orig.)

  6. On energy-saving of central air-conditioners in green buildings%绿色建筑中央空调节能

    Institute of Scientific and Technical Information of China (English)

    冯润娣

    2011-01-01

    阐述了绿色建筑的含义及我国绿色建筑的发展现状,指出建筑节能成为绿色建筑的核心内容,分析了中央空调系统在许多企业中所占的能耗比例越来越大,通过对中央空调实施有效的节能措施,达到节能的效果。%The paper illustrates the concept of the green buildings and the development status for the green buildings in China,points out the architectural energy-saving as the core content for the green buildings,analyzes the increasing consumption percentage of the central air-conditioner system in many enterprises,so as to achieve the energy-saving effect by implementing the effective energy-saving measures for the central air-conditioners.

  7. 恒温恒湿空调机PLC控制程序优化%Optimization of the PLC Control Program of Constant Temperature and Humidity Air Conditioners

    Institute of Scientific and Technical Information of China (English)

    戴建国

    2014-01-01

    optimized the PLC control program of constant temperature and humidity air conditioners in the production areas of Guangzhou Cigarette Factory. Using the methods of adjusting air moisture content of the air supply outlet to adjust relative air humidity, adopting cascade PID double loop adjustment in the PID algorithm of temperature and humidity, increasing the working condition recognition and correction of logic in each air conditioner and constructing intelligent air conditioning control module to realize automatic temperature and humidity adjustment, remarkable energy-saving effect has been achieved.%优化了广州卷烟厂生产区域空调恒温恒湿空调机的PLC控制程序,采取的措施包括调节送风口的空气中的含湿量从而调节环境的空气相对湿度,在温度及湿度的PID算法上采用串级PID双环调节,在各台空调机增加工况识别及修正逻辑,构建智能空调控制模块实现温湿度自动偏移等,取得了显著的节能效果。

  8. RESULTS OF USING MOBILE AIR CONDITIONER TO CONTROL CORN TEMPERATUER IN SILO IN SOUTH OF CHINA%南方立筒仓应用移动空调控温储存玉米研究

    Institute of Scientific and Technical Information of China (English)

    黄启迪

    2012-01-01

    对立筒仓的玉米应用移动空调进行控温储存试验,试验表明通过空调间歇性控温能确保玉米安全度夏储存安全,降低粮食保管费用.%Mobile air conditioner was used to control corn temperature in silo. The results showed that intermittent ventilation by using air conditioner can ensure corn stored safely in summer, it also can reduce storage costs.

  9. 新型车用空调平行流蒸发器湿工况性能的研究%A Research on the Wet Performance of New Parallel Flow Evaporator for Automotive Air Conditioners

    Institute of Scientific and Technical Information of China (English)

    施骏业; 瞿晓华; 祁照岗; 陈江平

    2011-01-01

    对新型车用空调平行流蒸发器湿工况性能进行了试验研究,并与层叠式蒸发器进行了比较.动态浸渍试验结果表明平行流蒸发器凝水排除能力较优;焓差法试验结果表明,在不同的稳定工况下,与层叠式蒸发器相比,平行流蒸发器的制冷能力较强(最高差3.3%),空气侧压降较高,全换热系数大21.3%~29%,除湿率略高.试验结果总体表明,新型平行流蒸发器性能优良,完全可以取代层叠式蒸发器.%An experimental study is carried out on the wet performance of new parallel flow evaporator for automotive air conditioners, which is then compared with baseline laminated evaporator.Dynamic dip test results show that parallel flow evaporator has better condensate drainage performance.The results of enthalpy difference test reveal that, under different working conditions, compared with laminated evaporator, the parallel flow evaporator has slightly higher cooling capacity (up to 3.3% difference), higher air side pressure drop, 21.3% ~29% higher over all heat transfer coefficient and slightly higher dehumidify rate.The results of all tests indicate that the new parallel flow evaporator has excellent performance and can by all means replace laminated evaporator.

  10. Analysis of annual cooling energy requirements for glazed academic buildings

    Energy Technology Data Exchange (ETDEWEB)

    Sulaiman, S.A. [Universiti Teknologi Petronas, Tronoh, Perak (Malaysia). Dept. of Mechanical Engineering; Hassan, A.H. [Vinyl Chloride Malaysia Sdn Bhd, Terengganu (Malaysia). Dept. of Engineering

    2011-07-01

    Malaysia experienced rapid increase in energy consumption in the last decade due to its high economic growth and increase in the standard living of household. Energy is becoming more costly and the situation is worsened by the global warming as a result of greenhouse gas emission. A more efficient energy usage and significant reduction in the released emission is therefore required. Space cooling with the use of air conditioners is practiced all year round in Malaysia and this accounts for 42% of total electricity energy consumption for commercial buildings and 30% of residential buildings. Reduction in the energy used for cooling in the built environment is a vital step to energy conservation in Malaysia. The objective of the present study was to analyze the annual cooling energy of highly glazed academic buildings which are located in a university in Malaysia. The outcome of the study would enable further remedial actions in reducing the energy consumption of the buildings' air conditioning system. The study is conducted by computer simulation using EnergyPlus software to calculate the cooling energy of a selected building or area. Comparison is made against the rated equipment load (i.e., the air handling unit) installed in the buildings. Since the buildings in the present study are not constructed parallel to each other the effect of building orientations with respect to the sun positions are also studied. The implications of shades such as venetian blind on the cooling energy are investigated in assessing their effectiveness in reducing the cooling energy, apart from providing thermal comfort to the occupants. In the aspect of operation, the present study includes the effects of reducing the set point air temperature and infiltration of outdoor air due to doors that are left open by the occupants. It is found from the present study that there are significant potentials for savings in the cooling energy of the buildings.

  11. Development of an Integrated Residential Heating, Ventilation, Cooling, and Dehumidification System for Residences

    Energy Technology Data Exchange (ETDEWEB)

    Hoeschele, M.A.; D.A. Springer

    2008-06-18

    The Need and the Opportunity Codes such as ASHRAE 90.2 and IECC, and programs such as Energy Star and Builders Challenge, are causing new homes to be built to higher performance standards. As a result sensible cooling loads in new homes are going down, but indoor air quality prerogatives are causing ventilation rates and moisture loads to increase in humid climates. Conventional air conditioners are unable to provide the low sensible heat ratios that are needed to efficiently cool and dehumidify homes since dehumidification potential is strongly correlated with cooling system operating hours. The project team saw an opportunity to develop a system that is at least as effective as a conventional air conditioner plus dehumidifier, removes moisture without increasing the sensible load, reduces equipment cost by integrating components, and simplifies installation. Project Overview Prime contractor Davis Energy Group led a team in developing an Integrated Heating, Ventilation, Cooling, and Dehumidification (I-HVCD) system under the DOE SBIR program. Phase I and II SBIR project activities ran from July 2003 through December 2007. Tasks included: (1) Mechanical Design and Prototyping; (2) Controls Development; (3) Laboratory and Field Testing; and (4) Commercialization Activities Technology Description. Key components of the prototype I-HVCD system include an evaporator coil assembly, return and outdoor air damper, and controls. These are used in conjunction with conventional components that include a variable speed air handler or furnace, and a two-stage condensing unit. I-HVCD controls enable the system to operate in three distinct cooling modes to respond to indoor temperature and relative humidity (RH) levels. When sensible cooling loads are high, the system operates similar to a conventional system but varies supply airflow in response to indoor RH. In the second mode airflow is further reduced, and the reheat coil adds heat to the supply air. In the third mode, the

  12. 空调器运行过程能值分析%Emergy Analysis on the Operation of an Air Conditioner

    Institute of Scientific and Technical Information of China (English)

    卢苇; 郑立星; 曾钰姣; 潘树林

    2011-01-01

    The emmergy analysis model of the operation of an air conditioner was established and some emergy indicators, such as transformity ( TV) , net emergy yield ratio ( EYR ) , environmental loading ratio ( ELR) and emergy sustainable index (ESI) ,were proposed based on this model. Besides,the formulae of environmental services were put forward. With the increase of outdoor ambient temperature or the decrease of indoor return air temperature, Tt and ELR rise, while EYR and ESI diminish. Those indicate that the air conditioner consumes more resources and the system sustainability decreases. The emergy analysis is more profound and comprehensive than the conventional thermodynamic analysis. The proposed emergy indicators present the total resources (including emergy resource) use efficiency of the system. Furthermore, different types of pollution can be quantitatively compared with according to emergy analysis, which finds out the thermal pollution ( a kind of energetic pollution) from the operation of an air conditioner consumes more than 7000 times as many environmental services as the simultaneous material pollution does.%建立了空调器运行过程能值分析模型,依据该模型构建了能值转换率(Tr)、净能值产出率(EYR)、环境负荷率(ELR)和能值可持续性指数(ESI)等能值指标,并给出了环境服务的计算式.随室外环境温度升高或室内回风温度降低,空调器的Tr增大、EYR减小、ELR增大、ESI减小,表明空调器消耗的资源增多,系统可持续性降低.能值分析比常规热力学分析深刻、全面,能值指标反映了系统包括能源在内的总资源利用效率.此外,能值分析实现了不同类型污染对环境影响的定量比较,发现空调器运行过程产生的热污染(能量型污染)所消耗的环境服务比物质型污染多7000余倍.

  13. 浅析某血液制品车间的洁净空调设计%Brief Analysis of Design of Cleaning Air-conditioner Used in One Blood Product Workshop

    Institute of Scientific and Technical Information of China (English)

    邓盼盼

    2015-01-01

    Based on the design of cleaning air-conditioner used in one blood product workshop, and combined with the special condition and design requirements, the principles and methods in designing cleaning air-conditioner were introduced in this article. At the same time, the notices in the design of cleaning air-conditioner and the special features in designing cleaning air-conditioner for blood products were analyzed and discussed.%以某血液制品生产车间的洁净空调设计过程为依据,结合该类药品生产的特殊情况及设计要求,介绍了洁净空调系统设计的原则及方法等问题,分析探讨了洁净空调设计时应该注意的事项以及该类药品的洁净空调设计的特殊性。

  14. A Scheme of Complying the Safe Standard for Axis of Motor in Air-Conditioner Outdoor Unit%空调室外电机轴的标准符合性研究

    Institute of Scientific and Technical Information of China (English)

    臧松彦; 马洁丹

    2014-01-01

    Aiming at the safety problem of grounding continuity of axis of the air-conditioner outdoor unit motor, this paper performs the analyses for the question, by means of the analysis of relevant safety standards for air conditioner and the judgment of the grounding reliability for ball bearing in CTL decision. Finally, it proposes a scheme that electromotor in air-conditioner uses ball-bearing to comply with its grounding reliability of standard, with the structure of air-conditioner and electromotor.%本文针对本文针对空调室外机轴接地连续性的安全问题展开分析通过剖析空调相关安全标中准针对空调器具对应条款的具体要求以及CTL决议针对电机球型轴承对可靠性接地的判定,结合空调外机结构、电机结构,提出空调电机轴采用球型轴承的方案,解决其接地的标准符合性。

  15. 用于可燃制冷剂空调器测试的焓差试验室设计%Enthalpy Test Apparatus Design for Flammable Refrigerants Testing Air Conditioner

    Institute of Scientific and Technical Information of China (English)

    戴雪伟; 李敏; 吴俊荣; 姜敬德; 金星; 李瑛

    2014-01-01

    根据相关安全性要求对可燃制冷剂空调器焓差试验室的设计进行了研究,同时运用在制冷产品检测和试验装置研制工作中积累的实践经验,对传统空调器焓差试验室在电气、可燃制冷剂浓度监测和强制通风系统、可燃制冷剂空调器试验房间、空气处理机等方面进行技术改造和再设计,使其具有防爆能力,以满足可燃制冷剂空调器的测试要求。%According to the relevant safety requirements, the design of flammable air conditioner refrigerant enthalpy difference lab was studied. Development of work experience in refrigeration products inspection and testing device, the traditional air conditioner enthalpy difference lab was modified and redesigned in the electrical, flammable refrigerant concentration monitoring and forced ventilation system, flammable refrigerant air conditioner test room, air processor and so on, and had the ability to meet the explosive, flammable air conditioner refrigerant testing requirements.

  16. Seasonal performance of air conditioners - an analysis of the DOE test procedures: the thermostat and measurement errors. Report No. 2

    Energy Technology Data Exchange (ETDEWEB)

    Lamb, G.D.; Tree, D.R.

    1981-01-01

    Two aspects of the DOE test procedures are analyzed. First, the role of the thermostat in controlling the cycling of conditioning equipment is investigated. The test procedures call for a cycling scheme of 6 minutes on, 24 minutes off for Test D. To justify this cycling scheme as being representative of cycling in the field, it is assumed that the thermostat is the major factor in controlling the cycle rate. This assumption is examined by studying a closed-loop feedback model consisting of a thermostat, a heating/cooling plant and a conditioned space. Important parameters of this model are individually studied to determine their influence on the system. It is found that the switch differential and the anticipator gain are the major parameters in controlling the cycle rate. This confirms the thermostat's dominant role in the cycling of a system. The second aspect of the test procedures concerns transient errors or differences in the measurement of cyclic capacity. In particular, errors due to thermocouple response, thermocouple grid placement, dampers and nonuniform velocity and temperature distributions are considered. Problems in these four areas are mathematically modeled and the basic assumptions are stated. Results from these models help to clarify the problem areas and give an indication of the magnitude of the errors involved. It is found that major disagreement in measured capacity can arise in these four areas and can be mainly attributed to test set-up differences even though such differences are allowable in the test procedures. An understanding of such differences will aid in minimizing many problems in the measurement of cyclic capacity.

  17. CO{sub 2} leak detection in motor car air conditioner components; CO{sub 2}-Lecksuche an Teilen fuer Automobilklimaanlagen

    Energy Technology Data Exchange (ETDEWEB)

    Schopphoff, A. [Pfeiffer Vacuum, Asslar (Germany)

    2005-07-01

    A test chamber is presented which can detect leak rates of < 0,5 g/a in a CO{sub 2} air conditioner. Requirements are: 1. a low CO{sub 2} background, which is achieved by evacuation of a vacuum chamber; 2. a sensitive sensor (mass spectrometer) with equally high sensitivity for all gases. [German] Mit Hilfe der vorgestellten Testkammer lassen sich Leckraten von < 0,5 g/a in einer CO{sub 2}-Klimaanlage detektieren. Voraussetzung sind: 1. ein niedriger CO{sub 2} Untergrund, der in diesem Aufbau durch das Evakuieren einer Vakuumkammer erreicht wird, und 2. ein empfindlicher Sensor, der alle Gase mit gleicher hoher Genauigkeit messen kann (Massenspektrometer).

  18. Effect of the air outlet louver on the noise generated by the outdoor set of a split-unit air conditioner

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Junwei; Ding, Guoliang [Department of Power and Energy Engineering, Institute of Refrigeration and Cryogenics, Shanghai Jiao Tong University, 1954 Huashan Road, Shanghai 200030 (China)

    2006-10-15

    In order to analyze the influence of the air outlet louver on the noise generated by the outdoor set of a split-unit air conditioner, the flow field in the outdoor set is simulated with the CFD software STAR-CD. The relative turbulent intensities are computed and the influence of the shape and the steel wire diameter of the air outlet louver on the noise generated by the outdoor set is analyzed. The results of computation and experiment show that the circular shape of air outlet louver gives benefit of noise decrease. An air outlet louver with different diameters of steel wires is designed on the basis of analysis of the influence of the steel wire diameter of the air outlet louver on the noise. The computation and experiment validate that the air outlet louver with different diameters of steel wires can improve the aerodynamic performance and reduce the noise generated by the outdoor set. (author)

  19. Power-supply control circuit to reduce standby power consumption of air conditioner%一种能够降低空调待机功耗的电源控制电路

    Institute of Scientific and Technical Information of China (English)

    樊建海

    2012-01-01

    A power-supply control circuit was designed to reduce the standby power consumption of air conditioners. The control circuit determines the working status of an air conditioner by a sampling circuit to detect the actual operating current, and cuts off the power at socket automatically when the air conditioner is in standby mode for more than a minute or so. The actual measurement proves that the control circuit can effectively reduce the standby power consumption of air conditioner. The standby power consumption is less than 1 W when the control circuit is working. The optocoupler triac taken as a core element and the infrared receiver are used in the control circuit. The control circuit does not affect the normal use of the air conditioner's remote controller when it is working%为了有效降低空调的待机功耗,设计了一种旨在降低空调待机功耗的电源控制电路.该控制电路通过取样电路检测空调实际工作电流的大小,判断空调的工作状态,当检测到空调处于待机状态超过1 min左右,控制电路自动切断空调插座的电源.实测证明该控制电路可以有效降低空调的待机功耗,可以做到待机功耗不大于1W.该控制电路采用光耦可控硅作为核心控制元件,控制电路中使用了红外接收器,其正常工作时不会影响空调遥控器的正常使用.

  20. Solar space heating and cooling by selective use of the components of a desiccant cooling system

    Science.gov (United States)

    Abbud, Ihsan Aladdin

    The economic advantages of by-passing various components of a desiccant cooling system under conditions not requiring their use are estimated by evaluating the annual costs of heating and cooling a commercial building in three representative U.S. cities. Life-cycle costs of systems employing solar heat for space heating and desiccant regeneration are compared with those using electric heat. The costs of purchasing and operating heating and desiccant cooling systems, with and without solar heat supply, are compared with those employing conventional heating and vapor compression cooling. The conditions under which commercial buildings can be cooled with desiccant systems at costs competitive with conventional systems are identified. A commercially available vapor compression air conditioner is used as a standard of comparison for energy consumption and room comfort. Heating and cooling requirements of the building are determined by use of the BLAST computer model in a simulation of long term system operation. Performance of the desiccant cooling system and life cycle savings obtained by its use are determined by simulation employing the TRNSYS computer model. TRNSYS compatible subroutines are developed to simulate operation of the desiccant equipment, the building, and the controllers that operate and monitor the system components. The results are presented in tabular and graphical form. This study shows that in the widely different climates represented in Los Angeles, New York, and Miami, by-passing various components in the desiccant cooling system when they are not needed is economically advantageous. Operation cost of the complete system decreased by 47.3% in Los Angeles, by 30.9% in New York City, and by 23.9% in Miami by not operating the desiccant wheel and other elements. The ventilation desiccant cooling system has major economic advantage over conventional systems under conditions of moderate humidity, as in Los Angeles and New York City. In Miami, however

  1. Research on influence law of capillary length on performance of room air conditioner in non-standard working condition%非标工况下毛细管长度对家用空调器性能影响规律的研究

    Institute of Scientific and Technical Information of China (English)

    段亮; 熊军; 陈绍林

    2012-01-01

    通过研究家用空调器的制冷量、能效比、排气温度、吸气温度等随室外温度和毛细管长度的变化规律,得出增加毛细管长度有利于提升高温工况下的制冷量,缩短毛细管长度有利于提升低温工况下的制冷量的结论,对于空调系统匹配有一定的指导意义.%The influence law of capillary length and outdoor temperature on cooling capacity, COP, exhaust temperature, suction temperature of room air conditioner are analyzed. The results show that increasing capillary length is benefit for cooling capacity under high temperature condition and decreasing length brings advantage to cooling capacity under low temperature condition. The study will provide reference for air-conditioning system matching.

  2. Temperature control of bench-scaled batch reactor equipped with a monofluid heating/cooling system

    Science.gov (United States)

    Teng, Hai-peng; Song, Yi-ming

    2014-04-01

    An advanced control concept, Predictive Functional Control (PFC), is applied for temperature control of a bench-scaled batch reactor equipped with monofluid heating/cooling system. First principles process models are developed. Based on achieved models, significant process variables, which are difficult or impossible to measure online, are estimated from easily measured variables, and cascade PFC control strategy has been projected and implemented in Matlab R14. The dynamics of individual subunits is explicitly taken into consideration by internal model in the control algorithms, and model uncertainty, various process disturbances are compensated by modification of internal model. The experimental results present an excellent capability of tracking the set point, and the success of PFC technique as a process control paradigm is illustratively demonstrated.

  3. Highly efficient heat recovery system for phosphoric acid fuel cells used for cooling telecommunication equipment

    Science.gov (United States)

    Ishizawa, Maki; Okada, Shigeru; Yamashita, Takashi

    To protect the global environment by using energy more efficiently, NTT is developing a phosphoric acid fuel cell (PAFC) energy system for telecommunication cogeneration systems. Fuel cells are used to provide electrical power to telecommunication equipment and the heat energy is used by absorption refrigerators to cool the telecommunication rooms throughout the year. We have recently developed a highly efficient system for recovering heat and water from the exhaust gases of a 200-kW (rated power) fuel cell. It is composed of a shell-and-tube type heat exchanger to recover high-temperature heat and a direct-contact cooler to recover the water efficiently and simply. The reformer and cathode exhaust gases from the fuel cell are first supplied to the heat exchanger and then to the cooler. The high-temperature (85-60°C) heat can be recovered, and the total efficiency including the heat recovered from the fuel-cell stack coolant can be improved by supplying the recovered heat to the dual-heat-input absorption refrigerator. The water needed for operating the fuel cell is also recovered from the exhaust gases. We are currently applying this heat and water recovery system to the PC25C-type fuel cell. Maximum total efficiency including electrical power efficiency is estimated to be 78% at the rated power of 200 kW: composed of 17% heat recovery for the fuel-cell stack coolant, 21% from the exhaust gas by improving the heat exchanger, and 40% from electrical conversion. Next, we plan to evaluate the usefulness of this heat recovery system for cooling telecommunication equipment.

  4. 基于太阳能辐射技术的热能转换空调制冷技术研究%Research on Cooler Air conditioner Based on Thermal Conversion of Solar Radiation Technology

    Institute of Scientific and Technical Information of China (English)

    李裕斌

    2016-01-01

    This paper presents technical approach on cooler air conditioner based on thermal conver-sion of solar radiation technology,i.e.transforming solar energy to heat energy,and use the heat energy to achieve refrigeration.We developed a new solar absorption air conditioning system based on the thermal conversion of solar radiation technology.Through verification studies,the operating characteristics of so-lar collector and heat storage system of air conditioning systems,and operating characteristics of the re-frigeration unit are verified.The experiment shows:the air conditioning system can operate continuously and stably for 8 hours.The average cooling capacity is 4 kW,and the maximum cooling capacity is 4.7 kW.The system COP average is 0.3.Therefore,this new solar absorption air conditioning system based on thermal conversion of solar radiation technology provides a feasible method to realize large scale,low cost application of solar energy.%给出了以太阳能辐射技术为基础的热能转换空调制冷技术的技术方法,即将太阳能转变成热能,使用热能进行制冷。以太阳能辐射技术的热能转换为基础,研制了新型的太阳能吸收式空调系统,并且通过实验研究,验证了该系统的集热、蓄热特性以及制冷机组的运行热性。实验表明,该空调系统可连续8 h 稳定地工作,最大制冷量可达到4.7 kW,平均值也可达到4 kW,该空调系统性能参数 COP,平均可达到0.3。因此,基于太阳能辐射技术的热能转换空调制冷技术为太阳能规模化、低成本应用提供了行之有效的新方法。

  5. Research Proposal for the Design and Engineering Phase of a Solar Heating and Cooling System Experiment at the Warner Robins Public Library, Warner Robins, Georgia. Submitted to the United States Energy Research and Development Administration.

    Science.gov (United States)

    Phillips, Warren H.; And Others

    A number of reasons are advanced to include a solar heating and cooling experiment in a library building. The unique aspects of the experiment are to be a seasonally adjustable collector tilt and testing of a new generation of absorption air conditioners. After a brief description of the proposed experiment, the proposal contains forms filed by…

  6. On comparison of schemes for air-conditioners in some super-high-rise office buildings%某超高层办公楼空调方案比选

    Institute of Scientific and Technical Information of China (English)

    杨帆; 张博

    2012-01-01

    Under the environment of prosperous development of super-high-rise buildings,the paper analyzes some problems in the design of the air-conditioner system in the super-high-rise buildings according to the features of the super-high-rise buildings and combining some practice experience,compares many schemes,and chooses the most economical and applied air-conditioner system.%在超高层建筑蓬勃发展的环境下,针对超高层建筑特点,结合实践经验,分析了超高层空调系统设计中需注意的问题,并对多种方案进行比选,进而选出最经济、最适用的空调系统。

  7. 两种可应用于恶劣环境的空调高防腐粉末%Two types of High-anticorrosive Powder Applied in Air-conditioner in Severe Environment

    Institute of Scientific and Technical Information of China (English)

    林路; 江秀华

    2014-01-01

    本文介绍两种空调用高防腐粉末的设计及在空调钢板上的应用,并通过盐雾实验来评定其防腐性能。结果表明,高防腐粉末可以有效提高空调的防腐性,扩大空调的使用环境。%This paper introduces the design of high-anticorrosive powder and the time the salt spray test in the steel plate of air-conditioner that can be attained. The practical conditions indicates that high-anticorrosive powder effec-tively improves the corrosion resistance of air-conditioner, and expands the operating environment of it.

  8. 移动空调噪声控制技术的研究与实践%The Research and Practice of Portable Air Conditioner Noise Control Technology

    Institute of Scientific and Technical Information of China (English)

    2012-01-01

    This text focuses on analyzing the reason and course of the noise generated from portable air conditioner. With test data and analytic technology, it concludes that present noise control technology for air conditioner, which was proved effective in practice.%  本文主要就移动空调器噪声产生的机理进行分析研究,应用试验分析技术和解析分析技术,从而总结出目前移动空调器的噪声控制方法,并且在实践中被证明是有效的。

  9. 管翅式全铝换热器在家用空调上的应用研究%Application Research on Fin Tube Aluminum Exchanger Used for Room Air Conditioners

    Institute of Scientific and Technical Information of China (English)

    2012-01-01

    In this article, fin tube aluminum exchanger used for room air conditioners are studied and ana-lyzed in different aspects, including material option, experiment analysis and welding technology. Moreover, the feasibility which fin tube aluminum exchanger may be used for room air conditioners is raised.%  本文对家用空调器换热器采用管翅式全铝换热器的材料选择、试验分析、焊接工艺等进行了研究和分析,提出了管翅式全铝换热器在家用空调器上的应用可行性。

  10. 浅析美国窗式空调的能效法规和标准%Analysis on Performance Code and Standard of Window Air Conditioner in USA

    Institute of Scientific and Technical Information of China (English)

    李玉玲; 范建波

    2015-01-01

    本文根据美国窗式空调的能效法规和标准,概括了美国对窗式空调的能效要求,介绍了评估方法、限值要求、计算方法、能源之星、能源标签.同时,结合美国最新能效政策,提出一些建议,以供参考.%According to the performance code and standard of window air conditioner in USA, this paper analyzes the performance degree of window air conditioner. It introduces the evaluation method, the limit value, the verification method, the Energy Star, and the energy label. Combined with the new policy of USA, some suggestions are provided to reference.

  11. Hardware Circuit Design of Intelligent Power Module FSBB30CH60DA in the Frequency Conversion Air-conditioner%变频空调智能功率模块FSBB30CH60DA硬件电路设计

    Institute of Scientific and Technical Information of China (English)

    刘群群

    2016-01-01

    With the continued popularity of frequency conversion air-conditioner, the application of intelligent power module is more and more widely. This paper studies the hardware circuit design of fair child power module FSB-B30CH60DA in the frequency conversion air-conditioner. It proves that this power module circuit has the characteris-tics of sable operation, low cost, and high value of utility.%随着变频空调的不断普及,智能功率模块的应用越来越广泛,本文研究变频空调中仙童功率模块FSBB30CH60DA的硬件电路设计,此功率模块电路性能可靠、成本低廉,实用性好。

  12. Wide multi air-conditioning system using new cooling medium HFC407C; Shinreibai HFC407C saiyo no wide multi eakon

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    A multi air conditioner for a building was commercialized which used, as a substitute for the cooling medium HCFC(hydro chloro fluoro carbon)22, a new cooling medium HFC(hydro fluoro carbon)407C containing no chlorine atom that destroys the ozone layer. Since the new cooling medium HFC407C was a mixture of three kinds of cooling mediums having different boiling points, there were problems such as lowered performance through composition change in a heat exchanger and lowered lubricity due to no chlorine content. In order to solve these problems, high efficiency of the heat exchanger by the use of a new heat exchanger tube was contrived, as were improvement of the compressor, employment of a new lubricating oil, security of performance and enhancement of reliability through the optimum super heat control. As a result, the new cooling medium series was completed succeeding the advantage of the wide multi air-conditioners. (translated by NEDO)

  13. 基于运行时间的变频型房间空调器季节能效比和潜力温度分析%Study on Seasonal Energy Efficiency Ratio and Potential Temperature of Variable-Speed Room Air Conditioner Based on Running Time

    Institute of Scientific and Technical Information of China (English)

    田镇; 谷波

    2013-01-01

    Seasonal energy efficiency ratio (SEER) of three variable-speed air conditioners under three kinds of running time was analyzed, respectively. Running time frequency (RTF) was taken to characterize the distribution of running time on temperature intervals. Bar graph was used to show the distribution of cooling load and energy consumption on temperature intervals. The results show that, the smaller the temperature under maximum RTF, the higher the SEER is. The faster the accumulation speed of RTF on low temperature intervals, the higher the SEER is. The regularity of distribution of cooling load and energy consumption on temperature intervals is decided by running time. The potential temperature can be showed on the bar graph, which has high reference value in performance optimization and selection of variable-speed room air conditioner.%计算了3台变频型房间空调器基于北京、上海、广州3种运行时间的季节能效比(SEER);采用运行时间频数(RTF)表征空调器运行时间在温度区间上的分布规律;绘制了3台空调器基于3种运行时间的制冷量和耗电量分布图.结果表明:RTF最大值对应的温度越小,SEER越大;RTF在低温段累计速度越快,SEER越大;空调器制冷量和耗电量在温度区间上的分布规律由运行时间决定;基于运行时间的制冷量和耗电量分布图能够直观反映当地的潜力温度,可为空调器性能的优化和选型提供参考依据.

  14. Fiscal 1997 survey report. Survey consigned to NEDO of the development of energy use rationalization home welfare equipment systems; 1997 nendo energy shiyo gorika zaitaku fukushi kiki system kaihatsu chosa. Itaku kenkyu seika hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    For the purpose of constructing new home welfare equipment systems of an energy effective use type, an investigational analysis was conducted of characteristics of the structure of houses considered of aged people, characteristics of the use of home welfare equipment, etc. As to the subject on space warming/cooling, it was found that the hour of stay-at-home of the aged tends to be longer, and the hour to be required for warming/cooling is longer, that the aged gradually lose senses regarding the peripheral environmental temperature, and the temperature to be considered should be at warmer/cooler levels, and that they are weak in heat shock, and the space of house where the temperature is uneven should be removed. Further, from the study in each welfare techno-house, possibilities were pointed out of further energy conservation in houses considered of the aged and home welfare equipment systems like the weight reduction of home welfare equipment systems and reduction of stand-by power, high air-tightness/high thermal insulation of houses for the aged, use of waste heat from air conditioners, introduction of solar energy to stand-by power and electrically-driven wheel chairs. 257 figs., 89 tabs.

  15. Solar-Powered, Liquid-Desiccant Air Conditioner for Low-Electricity Humidity Control: Report and Summary Report

    Energy Technology Data Exchange (ETDEWEB)

    Dean, J.; Kozubal, E.; Herrmann, L.; Miller, J.; Lowenstein, A.; Barker, G.; Slayzak, S.

    2012-11-01

    The primary objective of this project was to demonstrate the capabilities of a new high-performance, liquid-desiccant dedicated outdoor air system (DOAS) to enhance cooling efficiency and comfort in humid climates while substantially reducing electric peak demand at Tyndall Air Force Base (AFB), which is 12 miles east of Panama City, Florida.

  16. 几种隔音棉在空调器降噪中的应用%Application of Several Kinds of Cotton Insulations in the Noise Reduction of Split-system Air Conditioner

    Institute of Scientific and Technical Information of China (English)

    张帆

    2015-01-01

    空调器使用隔音棉吸收因压缩机运行产生的噪音。本文通过对隔音棉所使用的不同的纤维层和橡胶层进行分析,探讨不同材料的纤维层搭配不同材料的橡胶层对空调器压缩机噪音的影响。结论表明,空调器压缩机的噪音会因纤维层的不同、橡胶层的不同,表现出不同的噪音值。%The noise generated from compressor’s running will be reduced by using cotton insulation in a split-system air conditioner. In this paper, through the analysis of different cotton fiber layers and rubber layers, it discusses the influence of the noise of a split-system air conditioner when using different fiber layers and different rubber layers. It concludes that the noise of the compressor of the split-system air conditioner will vary depending on different fiber layers and different rubber layers.

  17. A Design and Optimization of the AIER-SIDE Configuration System for Wall-mounted Air Conditioner%壁挂式空调送风机系统设计优化

    Institute of Scientific and Technical Information of China (English)

    2012-01-01

      壁挂式空调送风机系统结构紧凑,影响其性能的因素很多,包括蒸发器布置、蜗舌间隙及尺寸以及风道型线等。本文采用送风机相似设计理论和CFD仿真模拟相结合的方法对壁挂式空调送风系统进行优化设计,取得了好的效果,设计精度高,开发周期短,表明该方法是壁挂式空调开发中一种行之有效的方法。%Wall-mounted air conditioner has a complicated configuration. There are a lot of performance factors, including evaporator disposal, tongue and flue. Applying the similar design method and CFD simula-tion, the paper makes a design for wall-mounted air conditioner. Results show the method is very accurate and is very useful for air conditioner design.

  18. On application of intelligent access control system in energy-saving of heating ventilation air-conditioner system%谈智能门禁系统在暖通空调系统节能中的应用

    Institute of Scientific and Technical Information of China (English)

    苏伟; 焦春玲; 罗炜

    2012-01-01

    The paper introduces the basic components and functions of the intelligent access control system,illustrates the application of the intelligent access control system in the various energy-saving of heating ventilation air-conditioner systems,including the workhouse heating system,the ventilation system,and the air-conditioner system,so as to direct the practice and to enhance the development of the energy-saving technique of the heating ventilation air-conditioner.%针对智能门禁系统的基本组成及功能进行了具体介绍,分别阐述了智能门禁系统在厂房采暖系统、通风系统、空调系统等不同的暖通空调系统节能中的应用,以期指导实践,促进暖通空调领域节能技术的发展。

  19. Cost benefit analysis and energy savings of using compression and absorption chillers for air conditioners in hot and humid climates

    Science.gov (United States)

    Shekarchian, M.; Moghavvemi, M.; Motasemi, F.; Mahlia, T. M. I.

    2012-06-01

    The electricity consumption growth has increased steadily in the recent decade which is a great concern for the environment. Increasing the number of high-rise air-conditioned buildings and the rapid use of electrical appliances in residential and commercial sectors are two important factors for high electricity consumption. This paper investigates the annual energy required for cooling per unit area and the total energy cost per unit area for each type of air conditioning systems in hot and humid climates. The effects of changing the coefficient of performance (COP) of absorption chillers on cost saving was also investigated in this study. The results showed that using absorption chillers for cooling will increase the amount of energy consumption per unit area; however the energy cost per unit area will decrease. In addition this research indicates that for each 0.1 increment in COP of absorption chillers, there is about 500 USD/m2 saved cost.

  20. Analysis on the Method to Start the Compressor of Inverter Air Conditioner%家用变频空调压缩机启动的浅析

    Institute of Scientific and Technical Information of China (English)

    李庆坚; 温得贤; 黄敬雁

    2014-01-01

    介绍并分析了目前行业内常用的压缩机启动方法,针对家用变频空调系统中压缩机在各负载工况下可能因启动力矩不足,而发生压缩机启动失败这一问题,通过对各品牌变频空调压缩机启动波形的分析以及实际的启动效果,得出一种较典型的压缩机启动方式。%This paper introduces and analyzes the common start methods of compressor in the industry. It is difficult to start the compressor of inverter air conditioner when the compressor is in harsh conditions. In this situation,it may put the compressor fail to start. Through the analysis of various brands of compressors of inverter air conditioners’start waveform, a typical starting mode of compressor is obtained.

  1. 齐鲁塑料厂中央空调节能改造%ENERGY- SAVING REVAMP OF CENTRAL AIR CONDITIONER

    Institute of Scientific and Technical Information of China (English)

    王效敏

    2011-01-01

    The central air conditioner in Plastics Complex supplied heat with desalinated water as heat medium which was heated by medium - pressure steam through a exchanger. After revamp, condensed liquid in styrene process is mainly used to preheat desalinated water through heat exchanger, and then heat exchanger for medium - pressure steam is used to adjust the temperature of desalinated water. This method is steam saving by means of waste heat utilization.%齐鲁塑料厂中央空调由原来的中压蒸汽通过换热器加热脱盐水作为热媒供热,改造后主要用苯乙烯工艺凝液通过换热器预热脱盐水,然后用中压蒸汽换热器调整脱盐水到合适的温度后供热。达到利用工艺凝液的余热,节省中压蒸汽的目的。

  2. Modular Design of Software for Air-conditioner Test System%空调检测系统软件的模块化设计

    Institute of Scientific and Technical Information of China (English)

    陈昕叶; 蔡燕君

    2013-01-01

    After modular design of the hardware and software for air-conditioner test system, only need to modularize the software, software engineers can easily construct a new system that meets the requirements. In this way, it can shorten software’s developing and manufacturing cycle, improve system software’s quality and stability, quick response for market changes, and increase the project’s throughput.%通过对空调检测系统中的硬件、软件进行模块化设计后,软件工程师只需要对软件进行积木式的模块组合,就可以轻松生成满足要求的新系统。从而缩短软件开发制造周期,提高系统软件的质量与稳定性,快速响应市场的变化,提高项目吞吐量。

  3. Concentrations of polybrominated diphenyl ethers (PBDEs) in central air-conditioner filter dust and relevance of non-dietary exposure in occupational indoor environments in Greece.

    Science.gov (United States)

    Besis, Athanasios; Katsoyiannis, Athanasios; Botsaropoulou, Elisavet; Samara, Constantini

    2014-05-01

    Polybrominated Diphenyl Ethers (PBDEs) are ubiquitous in the indoor environment owing to their use in consumer products and various studies around the world have found higher concentrations indoors than outdoors. Central air conditioner (A/C) systems have been widely used in many workplaces, therefore, studying of PBDEs in central A/C filter dust is useful to better understand the occurrences and health implications of PBDEs in indoor environments. The present study examined the occurrence of PBDEs in central A/C filter dust collected from various workplaces (n = 20) in Thessaloniki, Greece. The sum concentrations of 21 target congeners (∑21PBDE) in A/C dust ranged between 84 and 4062 ng g(-1) with a median value of 1092 ng g(-1), while BDE-209 was found to be the most abundant BDE congener. The daily intake via dust ingestion of PBDEs estimated for the employees of the occupational settings ranged from 3 to 45 ng day(-1) (median 12 ng day(-1)).

  4. Modeling and experimental study on performance of inverter air conditioner with variation of capillary tube using R-22 and R-407C

    Energy Technology Data Exchange (ETDEWEB)

    Sarntichartsak, Pongsakorn [Faculty of Technology and Management, Prince of Songkla University, Suratthani 84100 (Thailand); Monyakul, Veerapol [National Science and Technology Development Agency (NSTDA), Phathumthani 12120 (Thailand); Thepa, Sirichai [School of Energy and Materials, King Mongkut' s University of Technology Thonburi, Bangmod, Bangkok 10140 (Thailand)

    2007-02-15

    This paper focuses on an investigation of the proper capillary tube length for an inverter air conditioner. Air to air variable capacity systems with R-22 and R-407C were tested and modeled. First, the optimum refrigerant charge was determined for four capillary tubes at full load condition by varying the mass charge from 1.1 kg to 1.9 kg. The capillary tube lengths were 1.016 m, 0.914 m, 0.813 m and 0.711 m. The two zone model, the distributed model and the combined model were compared to estimate the optimal charge inventory. The combined model analysed a simple path evaporator, a complex path condenser with a two zone model and a distributed model, respectively. It obtained good agreement with experimental results for the system performances and the optimum mass charge. Furthermore, four capillary tubes with specific optimum mass charges were investigated at compressor frequencies in a range of 30-50 Hz. The R-22 capillary tube obtains the best performance with the addition length of 1.016 m at the lowest frequency. Especially, the length of 0.813 m with R-407C is the appropriate size at the operation frequency of 30-35 Hz. The base capillary tube of 0.914 m is optimum at other frequencies. The model prediction agrees with the experimental data in a range of 40-50 Hz. (author)

  5. Proposal for the award of an industrial support contract for dismantling LEP cooling and ventilation equipment

    CERN Document Server

    2000-01-01

    This document concerns the award of an Industrial Service contract for dismantling LEP cooling and ventilation equipment. Following a market survey carried out among 68 firms in fourteen Member States, a call for tenders (IT-2658/ST/SL) was sent on 11 February 2000 to 14 firms and one consortium in eight Member States. By the closing date, CERN had received nine tenders from seven firms and two consortia in six Member States. The Finance Committee is invited to agree to the negotiation of a contract with the firm ZVVZ (CZ), the lowest bidder, for a total amount of 822 005 Swiss francs, not subject to revision. The contract will include options for additional dismantling work in the LEP structure, specified in the tender, for a total amount of 313 311 Swiss francs, not subject to revision, bringing the total amount to a maximum of 1 135 316 Swiss francs, not subject to revision. The firm has indicated the following distribution by country of the contract value covered by this adjudication proposal: CZ-100%.

  6. Double utilization of the roof. 'Solar green roofs' - the advantages are in the combination; Das Dach zweifach nutzen. 'SolarGruenDaecher - die Vorteile liegen in der Kombination

    Energy Technology Data Exchange (ETDEWEB)

    Mann, Gunter

    2013-06-01

    Air conditioners cooling with solar energy have already existed for a long time. The core principles are adsorption chillers, absorption chillers and DEC chillers. However, these chillers are relatively expensive compared to air conditioners in compression technology and therefore not often used in the mass market. Since January 2013, Sedna Aire Europe GmbH (Dortmund, Federal Republic of Germany) offers solar-assisted air-conditioners that cost the same as commercial non-solar comparable equipment and enable significant cost savings from the first year. In addition, these air-conditioners are designed as heat pumps, which can be heated.

  7. Italian WEEE management system and treatment of end-of-life cooling and freezing equipments for CFCs removal.

    Science.gov (United States)

    Sansotera, M; Navarrini, W; Talaeemashhadi, S; Venturini, F

    2013-06-01

    This study presents and analyzes the data of the Italian system for take-back and recovery of waste electrical and electronic equipments (WEEEs) in the start-up period 2008-2010. The analysis was focused particularly on the data about the treatment of end-of-life cooling and freezing equipments. In fact, the wastes of cooling and freezing equipments have a high environmental impact. Indeed, in their compressor oil and insulation polyurethane (PU) foams chlorofluorocarbon (CFC) ozone-depleting gases are still present. In the period 2001-2004 Northern Italy resulted the main source in Europe of CFCs. The European Directive on WEEE management was enacted in 2002, but in Italy it was implemented by the legislative Decree in 2005 and it became operational in 2008. Actually, in 2008 the national WEEE Coordination Centre was founded in order to organize the WEEE pick-up process and to control collection, recovery and recycling targets. As a result, in 2010 the average WEEE collection per capita exceeded the threshold of more than 4 kg per inhabitant, as well as cooling and freezing appliances represented more than one fourth of the Italian WEEE collection stream. During the treatment of end-of-life cooling and freezing equipments, CFCs were recovered and disposed principally by burner methods. The analyses of defined specimens collected in the treatment facilities were standardized to reliably determine the amount of recovered CFCs. Samples of alkaline solid salt, alkaline saline solution, polyurethane matrix and compressor oil collected during the audit assessment procedure were analyzed and the results were discussed. In particular, the analysis of PU samples after the shredding and the warm pressing procedures measured a residual CFCs content around 500-1300 mg/kg of CFCs within the foam matrix.

  8. A comparison of four methods to evaluate the effect of a utility residential air-conditioner load control program on peak electricity use

    Energy Technology Data Exchange (ETDEWEB)

    Newsham, Guy R., E-mail: guy.newsham@nrc-cnrc.gc.ca [National Research Council Canada-Institute for Research in Construction, Building M24, 1200 Montreal Road, Ottawa, Ontario, K1A 0R6 (Canada); Birt, Benjamin J. [National Research Council Canada-Institute for Research in Construction, Building M24, 1200 Montreal Road, Ottawa, Ontario, K1A 0R6 (Canada); Rowlands, Ian H. [University of Waterloo, Ontario (Canada)

    2011-10-15

    We analyzed the peak load reductions due to a residential direct load control program for air-conditioners in southern Ontario in 2008. In this program, participant thermostats were increased by 2 deg. C for four hours on five event days. We used hourly, whole-house data for 195 participant households and 268 non-participant households, and four different methods of analysis ranging from simple spreadsheet-based comparisons of average loads on event days, to complex time-series regression. Average peak load reductions were 0.2-0.9 kWh/h per household, or 10-35%. However, there were large differences between event days and across event hours, and in results for the same event day/hour, with different analysis methods. There was also a wide range of load reductions between individual households, and only a minority of households contributed to any given event. Policy makers should be aware of how the choice of an analysis method may affect decisions regarding which demand-side management programs to support, and how they might be incentivized. We recommend greater use of time-series methods, although it might take time to become comfortable with their complexity. Further investigation of what type of households contribute most to aggregate load reductions would also help policy makers better target programs. - Highlights: > We analyzed peak load reductions due to residential a/c load control. > We used four methods, ranging from simple comparisons to time-series regression. > Average peak load reductions were 0.2-0.9 kW per household, varying by method. > We recommend a move towards time-series regression for future studies. > A minority of participant households contributed to a given load control event.

  9. Alternative Room Cooling System

    Directory of Open Access Journals (Sweden)

    Md. Fazle Rabbi

    2015-06-01

    Full Text Available The rapidly growing population results in an increasing demand for much more residential and commercial buildings, which leads to vertical growth of the buildings and needs proper ventilation of those buildings. Natural air ventilation system is not sufficient for conventional building structures. Hence fans and air-conditioners are must to meet the requirement of proper ventilation as well as space conditioning. Globally building sector consumes largest energy in heating, cooling, ventilation and space conditioning. This load can be minimized by the application of solar chimney and modification in building structure for heating, cooling, ventilation and space conditioning. Passive solar cooling is a subject of interest to provide cooling by using the sun, a powerful energy source. This is done for ensuring human comfort in hot climates. ASHRAE (American Society of Heating, Refrigerating and Air Conditioning Engineers defines Comfort as ‘that state of mind which expresses satisfaction with the thermal environment.’ The present paper describes the development of a solar passive cooling system, which can provide thermal cooling throughout the summer season in hot and humid climates. The constructed passive system works on natural convection mode of air. Such system reduces the inside temperature of up to 5°C from the atmospheric temperature. Temperature can further be reduced by the judicious use of night ventilation.

  10. Accurate Measurement of Air Conditioner Motor Winding in Electrical Safety Testing%电气安全测试中空调器电机绕组的正确测量

    Institute of Scientific and Technical Information of China (English)

    肖凯佳

    2014-01-01

    GB 4706.32-2012《家用和类似用途电器的安全--热泵、空调器和除湿机的特殊要求》对家用及类似用途的空调器在安全方面作了强制性规定,其中第11章的发热试验是考察空调产品质量安全非常重要的指标,尤其是涉及电机的温度测量和计算繁琐且复杂,因此如何能够准确地对空调器电机绕组进行测量显得尤为重要。本文通过结合空调器安全标准条款要求,针对空调器电机在实际测试中的绕组测量展开对比分析,并总结提出科学精确的测量方法,以达到对整个空调产品的安全合格性更全面更准确地评估。%GB 4706.32-2012“Household and similar electrical appliances-Safety-Particular requirements for electrical heat pumps, air-conditioners and dehumidifiers”is the mandatory criterion for air conditioners with house-hold and similar purposes in terms of security, which the heating test of 11th chapter is a very important indicator for evaluating the safety of air conditioning products, particularly the measurement and calculation of fan motor tempera-ture is very complicated, so how to measured the windings of fan motor accurately is very important. In this paper, according to the requirement of air conditioners safety standards, we made a comparison and analysis for the windings measurement of air conditioner motor in the actual test, and put forward the scientific and precise measurement method, to achieve more comprehensive for the safety of the air conditioning products eligibility assessment more accurately.

  11. A Brief Discussion on the Development Trend of Auto- mobile Air Conditioner Evaporator from Physical Fac- tors%从物理因素浅谈汽车空调蒸发器的发展趋势

    Institute of Scientific and Technical Information of China (English)

    唐国艳

    2015-01-01

    This paper introduced the physical factors influencing automobile air conditioner evaporator, summarized the design methods and future development trend of automobile air condi-tioner evaporator, and worked out the most rational design scheme through comparisons.%本文介绍了影响汽车空调系统蒸发器的物理因素,总结了汽车空调系统蒸发器设计方法及未来发展趋势,通过对比得出最合理的设计方案。

  12. Performance analysis on utilization of sky radiation cooling energy for space cooling. Part 2; Hosha reikyaku riyo reibo system ni kansuru kenkyu. 2

    Energy Technology Data Exchange (ETDEWEB)

    Marushima, S.; Saito, T. [Tohoku University, Sendai (Japan)

    1996-10-27

    Studies have been made about a heat accumulation tank type cooling system making use of radiation cooling that is a kind of natural energy. The daily operating cycle of the cooling system is described below. A heat pump air conditioner performs cooling during the daytime and the exhaust heat is stored in a latent heat accumulation tank; the heat is then used for the bath and tapwater in the evening; at night radiation cooling is utilized to remove the heat remnant in the tank for the solidification of the phase change material (PCM); the solidified PCM serves as the cold heat source for the heat pump air conditioner to perform cooling. The new system decelerates urban area warming because it emits the cooler-generated waste heat not into the atmosphere but into space taking advantage of radiation cooling. Again, the cooler-generated waste heat may be utilized for energy saving and power levelling. For the examination of nighttime radiation cooling characteristics, CaCl2-5H2O and Na2HPO4-12H2O were tested as the PCM. Water was used as the heating medium. In the case of a PCM high in latent heat capacity, some work has to be done for insuring sufficient heat exchange for it by, for instance, rendering the flow rate low. The coefficient of performance of the system discussed here is three times higher than that of the air-cooled type heat pump system. 8 refs., 5 figs., 4 tabs.

  13. The development of a solar-powered residential heating and cooling system

    Science.gov (United States)

    1974-01-01

    Efforts to demonstrate the engineering feasibility of utilizing solar power for residential heating and cooling are described. These efforts were concentrated on the analysis, design, and test of a full-scale demonstration system which is currently under construction at the National Aeronautics and Space Administration, Marshall Space Flight Center, Huntsville, Alabama. The basic solar heating and cooling system under development utilizes a flat plate solar energy collector, a large water tank for thermal energy storage, heat exchangers for space heating and water heating, and an absorption cycle air conditioner for space cooling.

  14. Switching on the Aire conditioner.

    Science.gov (United States)

    Matsumoto, Mitsuru

    2015-12-01

    Aire has been cloned as the gene responsible for a hereditary type of organ-specific autoimmune disease. Aire controls the expression of a wide array of tissue-restricted Ags by medullary thymic epithelial cells (mTECs), thereby leading to clonal deletion and Treg-cell production, and ultimately to the establishment of self-tolerance. However, relatively little is known about the mechanism responsible for the control of Aire expression itself. In this issue of the European Journal of Immunology, Haljasorg et al. [Eur. J. Immunol. 2015. 45: 3246-3256] have reported the presence of an enhancer element for Aire that binds with NF-κB components downstream of the TNF receptor family member, RANK (receptor activator of NF-κB). The results suggest that RANK has a dual mode of action in Aire expression: one involving the promotion of mTEC differentiation and the other involving activation of the molecular switch for Aire within mature mTECs. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Air Conditioners%空调

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    空调的匹数,原指输入功率,包括压缩机,风扇电机及电控部分,因不同的品牌其具体的系统及电控设计差异,其输出的制冷量不同,故其制冷量以输出功率计算。一般来说,1匹的制冷量大致为2000大卡,换算成国际单位应乘以1.162,则1.5匹的空调应为2000大卡×1.5×1.162=3486(W),这里的瓦(VV)即表示制冷量。

  16. Air Conditioners%空调

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    随着五一期间连续几天的高温,感觉今年的夏天来得格外的早。这对于空调市场来说可是个好事,高温提前到来就意味着空调热卖期的提前到来。小编在五一期间也在各大卖场转了转,发现各大空调品牌的新款机型基本都已经上市,品牌间的 竞争也越发激烈起来。空调市场从不缺乏亮点.从价格战到新品战、从服务战到品牌博弈.

  17. Air Conditioners%空调

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    在炎夏到来之前.空调已经成为各大电器卖场的紧俏商品.在现在人们的消费水平之下.享受空调已经不是什么奢侈的愿望。对于大功率的空调.人们对它的普遍看法是:耗电巨大.价格昂贵。没错.就是这样.这样的空调似乎是针对企业、机关团体用户多些.而对于家用呢?我们走访了北京大中电器马甸店.从销售人员口中得知.在家用领域.购买这些大功率的空调的用户也不少.因为北京的高消费群体是不少的.像几款进口品牌的空调.都是原装进口的,

  18. Air Conditioners%空调

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    3匹的空调算是空调制冷大户了,一般家用空调产品都在3匹及以下,消费者购买柜机主要是摆放在客厅里,所以目前市场上的柜机空调外形都非常靓丽,以往空调都以白色为主色调,如果你现在再去卖场空调部转上一圈的话,

  19. Air Conditioner Compressor Performance Model

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Ning; Xie, YuLong; Huang, Zhenyu

    2008-09-05

    During the past three years, the Western Electricity Coordinating Council (WECC) Load Modeling Task Force (LMTF) has led the effort to develop the new modeling approach. As part of this effort, the Bonneville Power Administration (BPA), Southern California Edison (SCE), and Electric Power Research Institute (EPRI) Solutions tested 27 residential air-conditioning units to assess their response to delayed voltage recovery transients. After completing these tests, different modeling approaches were proposed, among them a performance modeling approach that proved to be one of the three favored for its simplicity and ability to recreate different SVR events satisfactorily. Funded by the California Energy Commission (CEC) under its load modeling project, researchers at Pacific Northwest National Laboratory (PNNL) led the follow-on task to analyze the motor testing data to derive the parameters needed to develop a performance models for the single-phase air-conditioning (SPAC) unit. To derive the performance model, PNNL researchers first used the motor voltage and frequency ramping test data to obtain the real (P) and reactive (Q) power versus voltage (V) and frequency (f) curves. Then, curve fitting was used to develop the P-V, Q-V, P-f, and Q-f relationships for motor running and stalling states. The resulting performance model ignores the dynamic response of the air-conditioning motor. Because the inertia of the air-conditioning motor is very small (H<0.05), the motor reaches from one steady state to another in a few cycles. So, the performance model is a fair representation of the motor behaviors in both running and stalling states.

  20. Gas-burning air cooling developed by leading gas enterprises (Toho Gas). Nagoyaka Home Yokota, a nursing home; Ote kakusha ni miru gas reibo no saiyo jirei (Toho Gas). Tokubetsu yogo rojin home `Nagoyaka House Yokota`

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-08-01

    Described herein is the air-conditioning system for Nagoyaka Home Yokota, a nursing home in Nagoya City. It is a 7-story building with a total floor area of 4,444m{sup 2}. The first and second floors are for common purposes (dinning rooms, bathrooms, etc.), and the upper floors are for a total of 39 residents. The air-conditioning system is divided into two lines, one for the residents and the other for offices, where each office is equipped with an individual heat-pump type air conditioner. The residential rooms are air-conditioned by the gas absorption type cool/hot water generating system (capacity: 120 refrigeration tons) installed on the roof, where each room is equipped with a fan coil unit on the ceiling to allow each resident to control temperature independently. The home is also equipped with gas-burning systems for hot water generators, clothes driers and cookers. These city gas burning systems support comfortableness of the home. 5 figs.

  1. 基于PIC18F45J10的TEC半导体工业空调控制系统%TEC Peltier Industry Air Conditioner Control System based on PIC18F45J10

    Institute of Scientific and Technical Information of China (English)

    李睿; 芮贤义

    2011-01-01

    This paper introduces the structure and advantage of TEC peltier industry air conditioner system at first, and its design by bilolar control based on PICI8F45510, describes its functions and features. Then research its working principle design its input main circuit, output load circuit etc. The experiment results indicate that TEC peltier industry air conditioner control system with low cost, high efficiency is feasible.%本文首先介绍了TEC半导体工业空调控制系统的结构和优点,设计了基于PIC18F45J10的双极性控制器构成的TEC半导体工业空调,阐述了其功能和特点.接着研究TEC半导体工业空调控制系统的工作原理,设计输入主电路,输出负载控制电路等.实验结果表明低成本,高效率的TEC半导体工业空调控制系统的可行性.

  2. 双变频压缩机并联系统及其在多联机上的应用%The System With Two Parallel Connected Variable Speed Compressors and Its Application on Multiple-split Air-conditioner

    Institute of Scientific and Technical Information of China (English)

    胡锐

    2014-01-01

    The system with two parallel connected variable speed compressors is a new air-conditioner system which has two variable speed compressors in a outdoor unit instead of one inverter compressor. Through theory analyzing and testing, we prove that this system is more efficient than the traditional system with one variable speed compressor, especially on multiple-split air-conditioner whose load is variable.%双变频压缩机并联系统是通过使用两台小排气量的变频压缩机代替传统的单变频压缩机的一种新型空调系统。经理论分析及试验验证,双变频压缩机并联系统应用于负荷变化大的多联机组时比传统的单压缩机系统能效优势明显。

  3. The System with Two Parallel Connected Variable Speed Compressors and Its Application on Multiple-split Air-conditioner%双变频压缩机并联系统及其在多联机上的应用

    Institute of Scientific and Technical Information of China (English)

    胡锐

    2014-01-01

    双变频压缩机并联系统是通过使用两台小排气量的变频压缩机代替传统的单变频压缩机的一种新型的空调系统。经理论分析及试验验证,双变频压缩机并联系统应用于负荷变化大的多联机组,比传统的单压缩机系统能效优势明显。%The system with two parallel connected variable speed compressors is a new air-conditioner system which has two variable speed compressors in a outdoor unit instead of one inverter compressor. Through theory analyzing and testing, we proved that this system is more efficient than the traditional system with one variable speed compressor, es-pecially on multiple-split air-conditioner whose load is variable.

  4. Study of Permanent Magnet Synchronous Motor Used in Compressor for High-Efficient Inverter Air Conditioner%高效变频空调压缩机用永磁同步电机研究

    Institute of Scientific and Technical Information of China (English)

    张少丕; 陈世元; 皮明超

    2014-01-01

    Critical dimension of permanent magnet synchronous motor used in compressor for the home inverter air conditioner was confirmed by magnetic circuit analysis method, and motor performances were calculated accurately by finite element method. Comparing the difference between theoretical designed value and testing value of motor performances, compared the performance of inverter compressor and the corresponding air conditioner, the actual test showed that this method was accurate and feasible.%拟采用磁路解法确认家用变频空调器的压缩机用调速永磁同步电机的关键尺寸,再利用有限元分析方法精确计算电机的各项性能。对比电动机性能的理论设计值与实际测试值的差异,同时对比了变频压缩机和对应空调器的性能,通过实际测试说明该方法的准确性与可行性。

  5. 一种应用功能可模块组合的空调操作器%An Operation Device of Air Conditioner Which Application Function Can Be Composite Module

    Institute of Scientific and Technical Information of China (English)

    2012-01-01

      本文介绍一种易于推广及应用的空调操作器。该操作器通过有线连接的方式与空调产品的主控板连接,实现应用功能的模块组合,满足个性化用户的需求。同时,企业可以把最新的应用技术分阶段开发,以有偿的方式服务客户。%This paper introduces a kind of operation device of air conditioner which is easy to promote and is applicable. This device connects to the control board of air conditioner by cable. The application functions which can be composite module are easy to meet the various needs of personalized customers. At the same time, the enterprise can integrate the latest technology developed in stages to service customer by the means of charge.

  6. 一种空调交流接触器用AgNi触点材料的研究%AgNi Contact Material for AC Contactor of Air Conditioner

    Institute of Scientific and Technical Information of China (English)

    2013-01-01

    AgNi contact materials used in AC contactors of air conditioners were introduced. Proper-ties of AgNi contact materials with different Ni contents and different types of additives were com-pared, including the physical properties, material losses, arc energy and welding force. Results show that, because of the requirements of high rated current and long service life, the optimum Ni content in AgNi contact materials for AC contactors of air conditioners is 15%. Meanwhile the addition of trace amounts of brittle substance will improve the electrical properties of AgNi materi-als.%  介绍了空调交流接触器用AgNi触点材料,比较了不同Ni含量和不同类型添加物的AgNi触点材料的力学物理性能、烧损量、燃弧能量以及熔焊力等。结果表明,对于额定电流大、电寿命要求高的空调接触器用AgNi触点材料,其最佳Ni含量为15%左右;添加微量脆性物质能改善AgNi触点材料的电性能。

  7. 基于随机振动时可靠性约束的商用室外机管路优化%Pipes Optimization of Outdoor Unit of Commercial Air Conditioner Based on Reliability Constraint during Random Vibration

    Institute of Scientific and Technical Information of China (English)

    2013-01-01

      应用ANSYS对随机振动下商用室外机管路的响应进行分析,应用Miner线性疲劳累计损伤理论和材料的S-N曲线,估算室外机的疲劳寿命,结合正交试验表,确定商用室外机管路最佳尺寸组合,提升室外机的疲劳寿命。%In this article, the FEA software ANSYS is used to simulate the stress distribution of the outdoor unit of commercial air conditioner caused by the random vibration. The Miner’s linear fatigue accumulation rule and the S-N curve of the materials are used to estimate the fatigue life of the outdoor unit of the commercial air conditioner. The orthogonal experiment is used to analyze the optimum size of pipe structure, so as to improve the fatigue life of outdoor unit.

  8. 节能型水源热泵中央空调在居住小区中的应用%On application of energy-saving water source heat pump center air-conditioner in residential complex

    Institute of Scientific and Technical Information of China (English)

    赵艳军

    2012-01-01

    The paper introduces the basic principle for the energy-saving water source heat pump center air-conditioner,has the detailed indication of the "green,environmental-friendly,energy-saving and comfortable" new resource,undertakes the comparative analysis by comparing it with other resources by the list intercomparison from the comfortableness,the initial investment and the running cost,and concludes the energy-saving geothermic air-conditioner can bring newer and more comfortable living environment%介绍了节能型水源热泵中央空调的基本原理,对这种"绿色、环保、节能、舒适"的新能源做了详尽的说明,并通过列表比对等方法与其他能源形式从舒适性、初投资及运行费等方面进行了对比分析,得出节能型地温中央空调将为居住小区带来全新和更为舒适的生活环境的结论。

  9. On application of heating ventilation air-conditioner energy-saving issue and ground source heat pump%谈暖通空调节能问题与地源热泵的实际应用

    Institute of Scientific and Technical Information of China (English)

    黄长晖

    2012-01-01

    针对暖通空调:市能问题进行了研究,结合实际案例介绍了地源热泵在工程项目中的应用,通过与以城市供热为热源的室内散热器取暖方案进行对比分析,得出地源热泵系统能够有效解决空调系统节能问题,值得推广。%The paper researches the energy-saving issue of heating air-conditioner, introduces the application of the ground source heat pump in the engineering program by combining with the factual cases, undertakes the comparative analysis of the heating scheme for the indoor radiator which regards the urban heating supply as the source, and concludes the ground source heat pump system can solve the energy-saving issue of the air-conditioner system, so it can be further applied.

  10. Cost-Effective Integration of Efficient Low-Lift Baseload Cooling Equipment: FY08 Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Katipamula, Srinivas; Armstrong, P. R.; Wang, Weimin; Fernandez, Nicholas; Cho, Heejin; Goetzler, W.; Burgos, J.; Radhakrishnan, R.; Ahlfeldt, C.

    2010-01-31

    Documentation of a study to investigate one heating, ventilation and air conditioning (HVAC) system option, low-lift cooling, which offers potentially exemplary HVAC energy performance relative to American Society of Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) Standard 90.1-2004.

  11. 房间空调器长效节能评价体系研究现状及发展趋势%Research Status and Development Trend of Evacuation System of Long-term Energy Conservation for Room Air Conditioners

    Institute of Scientific and Technical Information of China (English)

    朱京多; 陈争; 刘韧

    2015-01-01

    我国是世界上空调器发展最快的国家之一,伴随着空调器的快速发展,空调器的能效标准和评价方式及评价体系也在不断变化,考核指标及考核方法日新月异。本文通过对空调器能效标准体系以及影响空调长效性能因素的国内外研究现状进行分析,指出考虑多影响因素的长效节能空调器评价体系能够更加全面的对空调节能性能进行考察,有利于提高住宅和商业建筑房间空调器能效,推动中国空调市场向节能转变,真正实现家电行业节能减排。%China is one of the most promising countries in the world today, especially in the field of air conditioner industry. The energy efficiency standards, evaluation method and system, and index for air conditioner are also in constant changing with the rapid development of air conditioner industry of China. Through analyzing the research status of energy efficiency standard system of air conditioners and the factors influencing the long-term performance at home and abroad this paper points out that comprehensively considering the factors that influencing the evaluation system of long-term energy conservation air conditioners is able to comprehensively access the energy-saving performance of air conditioner. It helps to improve the energy efficiency of the residential and commercial building room air conditioner, promote the energy-saving trend of air conditioner market in China, and realize the energy conservation and emission reduction in household appliances industry.

  12. Effect of nanofluid on thermal performance of heat pipe with two evaporators; application to satellite equipment cooling

    Science.gov (United States)

    Mashaei, P. R.; Shahryari, M.

    2015-06-01

    A study on the behavior of nanofluid in a cylindrical heat pipe with two heat sources is performed to analyze the nanofluid application in heat-dissipating satellite equipment cooling. Pure water, Al2O3-water and TiO2-water nanofluids are used as working fluids. An analytical modeling is presented to predict the wall temperature profile for the heat pipe assuming saturated vapor and conduction heat transfer for porous media and wall, respectively. The effects of particle concentration levels (φ=0 (distilled water), 2, 4, and 8%), particle diameters (dp=10, 20, and 40 nm) on the local wall temperature, heat transfer coefficient, thermal resistance, and the size of the heat pipe are investigated. It is observed that the better wall temperature uniformity can be achieved using nanofluid which results in lower temperature difference between evaporators and condenser sections. Results reveal that applying nanoparticle with smaller size and higher concentration level increases heat transfer coefficient remarkably by reducing thermal resistance of saturated porous media. It is also found that the presence of nanoparticles in water can lead to a reduction in weight of heat pipe, and thus satellite, under nearly identical condition. The findings of this paper prove the potential of nanofluid in satellite equipment cooling application.

  13. Heat engineering characteristics of the radiator for effective electronic equipment cooling systems

    Directory of Open Access Journals (Sweden)

    Rudenko A. I.

    2011-06-01

    Full Text Available The article presents the results of heat transfer charac-teristics research of the radiator on basis of a heat pipe for cooling of personal computer elements. It is determined that using acetone and ethanol as heat carriers under heat flow density q4·104 W/m2 is preferable. It is shown that the introduced radiators are considerably more effective than the radiators of conventional design with flat heat exchange surface with a rectangle plate fin.

  14. The development of a solar residential heating and cooling system

    Science.gov (United States)

    1975-01-01

    The MSFC solar heating and cooling facility was assembled to demonstrate the engineering feasibility of utilizing solar energy for heating and cooling buildings, to provide an engineering evaluation of the total system and the key subsystems, and to investigate areas of possible improvement in design and efficiency. The basic solar heating and cooling system utilizes a flat plate solar energy collector, a large water tank for thermal energy storage, heat exchangers for space heating, and an absorption cycle air conditioner for space cooling. A complete description of all systems is given. Development activities for this test system included assembly, checkout, operation, modification, and data analysis, all of which are discussed. Selected data analyses for the first 15 weeks of testing are included, findings associated with energy storage and the energy storage system are outlined, and conclusions resulting from test findings are provided. An evaluation of the data for summer operation indicates that the current system is capable of supplying an average of 50 percent of the thermal energy required to drive the air conditioner. Preliminary evaluation of data collected for operation in the heating mode during the winter indicates that nearly 100 percent of the thermal energy required for heating can be supplied by the system.

  15. R290空调小管径翅片管换热器的设计方法%Design Method of Fin-and-tube Heat Exchanger with Smaller Diameter Tubes in R290 Air Conditioner

    Institute of Scientific and Technical Information of China (English)

    2012-01-01

    R290 is a potential alternative refrigerant for R22, however using R290 may result in the risk of firing. Promoting the use of smaller diameter tubes in R290 room air conditioner is an effective way to reduce refrigerant charge to avoid the risk of firing, but may cause reduction of air conditioner system performance, so it is needed to propose a design method of heat exchanger with smaller diameter tubes. The method of designing fin-and-tube heat exchanger with smaller tubes is proposed in this study. The method includes designing of fin configuration and designing of refrigerant circuits. In the design method, the fin configuration is designed by CFD-based method, and the refrigerant circuits are designed by distributed-parameter model based on graph theory. An evaporator of 5 mm diameter tubes was designed, and the performance of an air conditioner with the designed evaporator was tested to verify the rationality of design method.%  R290是R22潜在的优良替代制冷剂,但有高可燃性的缺点。采用小管径换热器可有效降低制冷剂充注量,保证R290空调使用安全,但小管径的采用可能会导致空调换热性能下降,因此,有必要提出小管径换热器的设计方法。本文提出了空调小管径换热器的设计方法,包括翅片结构设计和制冷剂流路设计。在设计方法中,采用基于CFD的方法设计翅片结构,采用基于图论的三维分布参数模型设计制冷剂流路。为验证设计方法的合理性,根据设计方法设计了5mm管蒸发器,并对采用5mm管蒸发器的空调整机进行了测试。

  16. Performance simulation of the JPL solar-powered distiller. Part 1: Quasi-steady-state conditions. [for cooling microwave equipment

    Science.gov (United States)

    Yung, C. S.; Lansing, F. L.

    1983-01-01

    A 37.85 cu m (10,000 gallons) per year (nominal) passive solar powered water distillation system was installed and is operational in the Venus Deep Space Station. The system replaced an old, electrically powered water distiller. The distilled water produced with its high electrical resistivity is used to cool the sensitive microwave equipment. A detailed thermal model was developed to simulate the performance of the distiller and study its sensitivity under varying environment and load conditions. The quasi-steady state portion of the model is presented together with the formulas for heat and mass transfer coefficients used. Initial results indicated that a daily water evaporation efficiency of 30% can be achieved. A comparison made between a full day performance simulation and the actual field measurements gave good agreement between theory and experiment, which verified the model.

  17. TACT1- TRANSIENT THERMAL ANALYSIS OF A COOLED TURBINE BLADE OR VANE EQUIPPED WITH A COOLANT INSERT

    Science.gov (United States)

    Gaugler, R. E.

    1994-01-01

    As turbine-engine core operating conditions become more severe, designers must develop more effective means of cooling blades and vanes. In order to design reliable, cooled turbine blades, advanced transient thermal calculation techniques are required. The TACT1 computer program was developed to perform transient and steady-state heat-transfer and coolant-flow analyses for cooled blades, given the outside hot-gas boundary condition, the coolant inlet conditions, the geometry of the blade shell, and the cooling configuration. TACT1 can analyze turbine blades, or vanes, equipped with a central coolant-plenum insert from which coolant-air impinges on the inner surface of the blade shell. Coolant-side heat-transfer coefficients are calculated with the heat transfer mode at each station being user specified as either impingement with crossflow, forced convection channel flow, or forced convection over pin fins. A limited capability to handle film cooling is also available in the program. The TACT1 program solves for the blade temperature distribution using a transient energy equation for each node. The nodal energy balances are linearized, one-dimensional, heat-conduction equations which are applied at the wall-outer-surface node, at the junction of the cladding and the metal node, and at the wall-inner-surface node. At the mid-metal node a linear, three-dimensional, heat-conduction equation is used. Similarly, the coolant pressure distribution is determined by solving the set of transfer momentum equations for the one-dimensional flow between adjacent fluid nodes. In the coolant channel, energy and momentum equations for one-dimensional compressible flow, including friction and heat transfer, are used for the elemental channel length between two coolant nodes. The TACT1 program first obtains a steady-state solution using iterative calculations to obtain convergence of stable temperatures, pressures, coolant-flow split, and overall coolant mass balance. Transient

  18. Model Selection of Cooling Equipment for Granular Fertilizers%颗粒肥料冷却设备的选型

    Institute of Scientific and Technical Information of China (English)

    李秋萍; 程建伟; 邵国兴

    2011-01-01

    在颗粒肥料生产中,产品的冷却是直接影响产品包装及成品质量的重要过程之一.介绍了转鼓冷却器、流化床冷却器、波面冷却器等几种适合于颗粒肥料冷却的设备,并对它们的工作原理和性能特点作了简单介绍和评述,供用户在设备选型时参考.%In the production of granular fertilizers, product cooling is one of the important processes that affect directly the product packaging and quality. Several cooling facilities are described suitable for granular fertilizers, such as the rotary drum cooler, fluid-bed cooler, wave surface cooler, etc.A brief account and review are given of their working principles and performance characteristics, as a reference for users in their model selection of equipment.

  19. Research Status of the Noise in Rotary Air Conditioner Compressor for Automotive%车用旋转式空调压缩机噪声研究现状

    Institute of Scientific and Technical Information of China (English)

    邹杨; 叶禾; 杨诚

    2012-01-01

    旋转式空调压缩机的噪声直接影响空调系统舒适性,回顾了旋转式压缩机噪声的国内外研究现状,对旋转式压缩机的噪声进行分类评述,最后讨论了目前研究存在的问题并对未来的研究做了展望.%The noise of rotary air conditioner compressor directly affects the comfort of air conditioning systems, this paper reviews the recent study at home and abroad which about the rotary compressor noise,classifies comments about those noises,and finally discusses the problems of current research and makes prospects for futher research.

  20. Cost-Effective Integration of Efficient Low-Lift Base Load Cooling Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Wei; Winiarski, David W.; Katipamula, Srinivas; Armstrong, Peter R.

    2008-01-14

    The long-term goal of DOE’s Commercial Buildings Integration subprogram is to develop cost-effective technologies and building practices that will enable the design and construction of net Zero Energy Buildings — commercial buildings that produce as much energy as they use on an annual basis — by 2025. To support this long-term goal, DOE further called for — as part of its FY07 Statement of Needs — the development by 2010 of “five cost-effective design technology option sets using highly efficient component technologies, integrated controls, improved construction practices, streamlined commissioning, maintenance and operating procedures that will make new and existing commercial buildings durable, healthy and safe for occupants.” In response, PNNL proposed and DOE funded a scoping study investigation of one such technology option set, low-lift cooling, that offers potentially exemplary HVAC energy performance relative to ASHRAE Standard 90.1-2004. The primary purpose of the scoping study was to estimate the national technical energy savings potential of this TOS.

  1. Efficient determination of crystallisation and melting points at low cooling and heating rates with novel computer controlled equipment

    Energy Technology Data Exchange (ETDEWEB)

    Wachter, Philipp [Institut fuer Physikalische und Theoretische Chemie der Universitaet Regensburg, Universitaetsstrasse 31, D-93040 Regensburg (Germany); Schweiger, Hans-Georg [Institut fuer Physikalische und Theoretische Chemie der Universitaet Regensburg, Universitaetsstrasse 31, D-93040 Regensburg (Germany); Continental Automotive Systems Division, Sickingenstrasse 29-38, D-10553 Berlin (Germany); Wudy, Franz [Institut fuer Physikalische und Theoretische Chemie der Universitaet Regensburg, Universitaetsstrasse 31, D-93040 Regensburg (Germany); Gores, Heiner J. [Institut fuer Physikalische und Theoretische Chemie der Universitaet Regensburg, Universitaetsstrasse 31, D-93040 Regensburg (Germany)], E-mail: Heiner.Gores@Chemie.Uni-Regensburg.de

    2008-10-15

    We studied melting and solidification points of 14 pure solvents and two ionic liquids with a recently constructed automatic computer-controlled equipment, which is able to record simultaneously temperature-time functions of up to 30 samples at very low heating and cooling rates down to 1.5 K . h{sup -1}. The effects of viscosity of the studied samples and of carbon fibres as an added crystallisation aid were also investigated. Equilibrium temperatures for the solid-liquid phase transition are in accordance with literature for materials that were often checked, such as acetonitrile, showing the quality of our new equipment, whereas the value of the transition temperature of some other materials differed from published results. It is shown that both the viscosity of the material and carbon fibres as crystallisation aids have an effect on supercooling. The value given for the equilibrium point of the ionic liquid trioctylmethylammonium trifluorocetate T{sub tr} = (285.62 {+-} 0.1) K is new.

  2. 空调内部管道运输和运行过程中的振动分析及改进%Analysis and Improvements for the Pipes of Air Conditioner for Transporting and Operating Process

    Institute of Scientific and Technical Information of China (English)

    彭景华; 吴帅

    2014-01-01

    空调内部的管道既是在运输和运行过程中最容易遭受破坏也是直接影响空调性能的必要组件。针对运输情形,本文首先利用ABAQUSE软件分析了管路的固有频率,进而通过增加管道约束的手段达到避免共振的目的。接着在压缩机出口处通过施加外部激励来模拟运行情形下的受迫振动情况,其位移结果与试验结果相符。通过进一步优化局部管道结构,成功降低了应力集中区的应力约15%。%In air conditioner,the pipes are not only the part that most probably damaged,but also the key part for well running. In this paper,the software Abaquse was used to study the vibrational status of the air conditioner. With modal anal-ysis,the constraints of the pipes were improved to increase the intrinsic frequency that we can avoid resonating in transport. The external loading was applied on the endpoints of the pipes to simulate the effect of the compressor when operating. The results agree well with the experimental results. By optimizing the local pipe structure,the maximum Mises stress can be de-creased by nearly 15%.

  3. 空调室外机气动与声学特性的研究进展%Advances in Investigation of Acoustic and Aerodynamic Noise in Air Conditioner Outdoor Unit

    Institute of Scientific and Technical Information of China (English)

    杨启容; 秦静静; 吴荣华; 王硕

    2015-01-01

    Noise in air conditioner outdoor unit includes mechanical noise,electromagnetic noise and aerodynamic noise.The effects of mechanic and electromagnetic noise are minor but aerodynamic noise effect is the key in the duct system of air condi-tioner outdoor unit.The history and u-to-date development of noise in air conditioner outdoor unit were reviewed,The detail analy-sis is carried out from three ways of methods of numerical modeling,experimental studies and modal analysis according to refer-ences.On the basis of the analysis and summary,the further needed work of noise reduction are put forward.%空调室外机噪声包括机械噪声、电磁噪声和气动噪声,其中机械噪声和电磁噪声在常规状态下影响较小,气动噪声是空调室外机风道系统的主要噪声。本文回顾了国内外关于空调室外机气动噪音的研究历史与现状,结合文献着重从数值模拟、试验研究以及模态分析几个方面进行了分析。经过分析总结,提出了进一步降噪需要开展的工作。

  4. 空间矢量SVPWM控制算法在变频空调设计中的应用%Application of SVPWM Control Method Based on Space Vector in Inverter Air-Conditioner Designing

    Institute of Scientific and Technical Information of China (English)

    朱福成

    2011-01-01

    To further reduce the noise, raises the efficiency of voltage, the voltage space vector SVPWM technology be adopted to design inverter air-conditioner. By the basic standard of motor's ideal magnetic flux with three-phase symmetrical sine wave voltage power supply is considered, use the actual magnetic flux with the inverter different switch pattern to approach the base director circle magnetic flux, compares the results to decide which time the inverter's switches open and pass, forms the PWM waveforms. And regards the inverter and the electrical motor as a whole to process, It has the merit of model to be simple, the torque pulsation be small, the noise be low, voltage use factor higher and so on. The theoretical analysis and the experimental result indicated that this method can definitely satisfy the inverter air-conditioner designing requirements.%为进一步减少噪音,提高电压利用率,采用空间电压矢量SVPWM技术进行变频空调设计.以三相对称正弦波电压供电时交流电动机的理想磁通为基准,用逆变器不同的开关模式所产生的实际磁通去逼近塞准圆磁通,由它们比较的结果决定逆变器的开、关,形成PWM波形.并把逆变器和电机看成一个整体来处理,具有模型简单、转矩脉动小、噪音低、电压利用率高等优点.理论分析及实验结果表明,该方法完全能够满足变频空调的设计要求.

  5. Algorithm of Air Conditioner Filter Screen Dust Degree Intelligent Detection Technology Based on PNN%基于PNN算法的空调过滤网积尘智能检测技术

    Institute of Scientific and Technical Information of China (English)

    李强; 吴志鹏; 朱良红; 霍军亚

    2015-01-01

    空调过滤网具有过滤灰尘,防止空调内部受到污染的作用.但是过滤网积尘之后,容易滋生细菌,同时也会增加风阻,减小空调的出风量,造成能源浪费.因此,用户需要知道过滤网的积尘程度,以便及时清洗.本文提出一种基于PNN神经网络算法的过滤网积尘智能检测技术,无需增加任何硬件成本,自动检测滤网积尘程度,通过手机APP提醒用户.通过实验验证,检测准确度达到100%,满足产品化需求.%Filter screen in air conditioner plays the role of filtering dust and preventing pollution in the interior of air conditioner. However, once the filter screen covered by dust, it is easy to breed bacteria, increase wind resistance, reduce air volume of air conditioning and cause energy waste. Therefore, users need to know the dust extent of filter screen, so that timely cleaning can be done. A new intelligent detection technique based on PNN algorithm is proposed in this paper. It detects dust extent automatically and reminds users through the APP in mobile phone without any other hardware. Through experiments, the accuracy of detection technology is 100%. It meets the demands of product.

  6. PERFORMANCE EVALUATION OF CEILING RADIANT COOLING SYSTEM IN COMPOSITE CLIMATE

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Anuj [Malaviya National Institute of Technology (MNIT), Jaipur, India; Mathur, Jyotirmay [Malaviya National Institute of Technology (MNIT), Jaipur, India; Bhandari, Mahabir S [ORNL

    2015-01-01

    Radiant cooling systems are proving to be an energy efficient solution due to higher thermal capacity of cooling fluid especially for the buildings that require individual zone controls and where the latent loads are moderate. The Conventional air conditioners work at very low temperature i.e.5-8 c (refrigerant evaporator inlet) while the radiant cooling systems, also referred as high temperature cooling system, work at high temperatures i.e. 14-18 c. The radiant cooling systems can maintain lower MRT (Mean Radiant Temperature) as ceiling panels maintain uniform temperature gradient inside room and provide higher human comfort. The radiant cooling systems are relatively new systems and their operation and energy savings potential are not quantified for a large number of buildings and operational parameters. Moreover, there are only limited numbers of whole building simulation studies have been carried out for these systems to have a full confidence in the capability of modelling tools to simulate these systems and predict the impact of various operating parameters. Theoretically, savings achieve due to higher temperature set point of chilled water, which reduces chiller-running time. However, conventional air conditioner runs continuously to maintain requisite temperature. In this paper, experimental study for performance evaluation of radiant cooling system carried out on system installed at Malaviya National Institute of Technology Jaipur. This paper quantifies the energy savings opportunities and effective temperature by radiant cooling system at different chilled water flow rates and temperature range. The data collected/ analysed through experimental study will used for calibration and validation of system model of building prepared in building performance simulation software. This validated model used for exploring optimized combinations of key parameters for composite climate. These optimized combinations will used in formulation of radiant cooling system

  7. Comparative analysis of cooling systems for energy equipment of combined heat and power plants and nuclear power plants

    Science.gov (United States)

    Reutov, B. F.; Lazarev, M. V.; Ermakova, S. V.; Zisman, S. L.; Kaplanovich, L. S.; Svetushkov, V. V.

    2016-07-01

    In the 20th century, the thermal power engineering in this country was oriented toward oncethrough cooling systems. More than 50% of the CHPP and NPP capacities with once-through cooling systems put into operation before the 1990s were large-scale water consumers but with minimum irretrievable water consumption. In 1995, the Water Code of the Russian Federation was adopted in which restrictions on application of once-through cooling systems for newly designed combined heat and power plants (CHPPs) were introduced for the first time. A ban on application of once-through systems was imposed by the current Water Code of the Russian Federation (Federal law no. 74-FZ, Art. 60 Cl. 4) not only for new CHPPs but also for those to be modified. Clause 4 of Article 60 of the Water Code of the Russian Federation contravenes law no. 7-FZ "On Protection of the Environment" that has priority significance, since the water environment is only part of the natural environment and those articles of the Water Code of the Russian Federation that are related directly to electric power engineering, viz., Articles 46 and 62. In recent decades, the search for means to increase revenue charges and the economic pressure on the thermal power industry caused introduction by law of charges for use of water by cooling systems irrespective of the latter's impact on the water quality of the source, the environment, the economic efficiency of the power production, and the living conditions of the people. The long-range annual increase in the water use charges forces the power generating companies to switch transfer once-through service water supply installations to recirculating water supply systems and once-through-recirculating systems with multiple reuse of warm water, which drastically reduces the technical, economic, and ecological characteristic of the power plant operation and also results in increasing power rates for the population. This work comprehensively substantiates the demands of

  8. Impact of the Cooling Equipment on the Key Design Parameters of a Core-Form Power Transformer

    Science.gov (United States)

    Orosz, Tamás; Tamus, Zoltán Ádám

    2016-12-01

    The first step in the transformer design process is to find the active part's key design parameters. This is a non-linear mathematical optimisation task, which becomes more complex if the economic conditions are considered by the capitalisation of the losses. Geometric programming combined with the method of branch and bound can be an effective and accurate tool for this task even in the case of core-form power transformers, when formulating the short-circuit impedance in the required form is problematic. Most of the preliminary design methods consider only the active part of the transformer and the capitalised costs in order to determine the optimal key design parameters. In this paper, an extension of this meta-heuristic transformer optimisation model, which takes the cost of the insulating oil and the cooling equipment into consideration, is presented. Moreover, the impact of the new variables on the optimal key design parameters of a transformer design is examined and compared with the previous algorithm in two different economic scenarios. Significant difference can be found between the optimal set of key-design parameters if these new factors are considered.

  9. Technical Subtopic 2.1: Modeling Variable Refrigerant Flow Heat Pump and Heat Recovery Equipment in EnergyPlus

    Energy Technology Data Exchange (ETDEWEB)

    Raustad, Richard; Nigusse, Bereket; Domitrovic, Ron

    2013-09-30

    enthalpy method where relevant air-side parameters were controlled while collecting output performance data at discreet points of steady-state operation. The primary metrics include system power consumption and zonal heating and cooling capacity. Using this test method, the measured total cooling capacity was somewhat lower than reported by the manufacturer. The measured power was found to be equal to or greater than the manufacturers indicated power. Heating capacity measurements produced similar results. The air-side performance metric was total cooling and heating energy since the computer model uses those same metrics as input to the model. Although the sensible and latent components of total cooling were measured, they are not described in this report. The test methodology set the thermostat set point temperature very low for cooling and very high for heating to measure full-load performance and was originally thought to provide the maximum available capacity. Manufacturers stated that this test method would not accurately measure performance of VRF systems which is now believed to be a true statement. Near the end of the project, an alternate test method was developed to better represent VRF system performance as if field installed. This method of test is preliminarily called the Load Based Method of Test where the load is fixed and the indoor conditions and unit operation are allowed to fluctuate. This test method was only briefly attempted in a laboratory setting but does show promise for future lab testing. Since variable-speed air-conditioners and heat pumps include an on-board control algorithm to modulate capacity, these systems are difficult to test. Manufacturers do have the ability to override internal components to accommodate certification procedures, however, it is unknown if the resulting operation is replicated in the field, or if so, how often. Other studies have shown that variable-speed air-conditioners and heat pumps do out perform their single

  10. Study on Variable Volume and Gas Injection DC Inverter Air Conditioner Compressor%变频变容喷气增焓空调压缩机的理论与实验研究

    Institute of Scientific and Technical Information of China (English)

    向卫民

    2016-01-01

    The lower heating capacity in low ambient temperature is the defect of the air-conditioner. Some schemes have been proposed to solve the problem, but they can't improve the quantity of heat more than 50%in low ambient tem-perature and improve efficiency in general temperature at the same time. This paper proposes a vapor-injection varicap compressor, and studies its heating capacity and efficiency properties. The experimental results show that the APF of the air-conditioner increased by 6%when using the vapor-injection varicap compressor, and the quantity of heat increased by 85%, at the same time.%低温制热能力不足问题一直是空调的诟病,研发人员在前期也提出过几种解决温制热量的方案,但都以难满足APF工况下的能效提升和低温-15℃环境温度下高制热量的两个目标。针对这一难题,提出一种集变频技术、变容技术和喷气增焓技术为一体的压缩机设计方案,通过原理分析进行了样机的结构设计,研究其性能及低温能力特性,经验证,搭载空调系统测试时,喷气能力能效提升效果明显,在喷气情况下,搭载系统APF比基准机型提高了约6%,同时,搭载系统的低温-15℃的制热能力相对基准机提升了约85%,效果显著。

  11. Modelagem de um condicionador de ar de alta precisão para uso em processamento agrícola Modeling of a high precision air conditioner for use in agricultural processing

    Directory of Open Access Journals (Sweden)

    Mauri Fortes

    2006-08-01

    Full Text Available Apresenta-se neste trabalho, estudo detalhado sobre a modelagem de um condicionador de ar com controle acurado de temperatura e umidade relativa. Desenvolveu-se um programa de computador que permite predizer o comportamento do sistema sob diferentes condições psicrométricas e de vazão do ar de entrada. O modelo global físico-matemático inclui equações de balanço de massa e de energia para três diferentes volumes de controle que compõem o condicionador. Modelaram-se os processos de mistura, evaporação (ou condensação simultânea de uma superfície d'água e de uma gota e o aquecimento de corrente de ar, separadamente. Propõem-se expressões semi-empíricas simples para os coeficientes de transferência de calor e massa inerentes ao processo de evaporação sobre uma superfície d'água e um modelo simplificado para o sistema de spray. Construiu-se um condicionador de ar no qual foram feitos testes experimentais para o ajuste das constantes que aparecem nas expressões para os coeficientes de transferência. Os dados obtidos validaram o modelo global, com precisão aceitável para projetos de engenharia.In this work, a detailed procedure for the analysis of an accurately controlled air conditioner is presented. A computer program, that allows predicting the behavior of the system under different psychrometric conditions and different input air mass flow rates, was developed. The global physical-mathematical model includes mass and energy conservation equations for three different control volumes that compose the conditioner. Thus, the processes of mixture of air, simultaneous evaporation (or condensation from a water surface and from a drop, and the air-stream heating are modeled separately. Simple semi-empiric expressions for heat and mass coefficients inherent to the evaporation process on a water surface are proposed as well a simplified model for the spray system. Experimental tests made on an air-conditioner allowed to obtain

  12. Development of a prototype thermoelectric space cooling system using phase change material to improve the performance

    Science.gov (United States)

    Zhao, Dongliang

    , for the thermoelectric cooling unit, for the PCM thermal storage unit, and for the outdoor air-water heat exchanger. When modeling PCM thermal storage unit, the enthalpy method has been adopted. Since natural convection has been observed in experiments playing a key effect on heat transfer in PCM, a staged effective thermal conductivity (ke) concept and modified Rayleigh (Ra) number formula have been developed to better capture natural convection's variable effects during the PCM charging process. Therefore, a modeling-based design procedure for thermoelectric cooling system integrating with PCM has been proposed. A case study has been completed for a model office room to demonstrate the qualitative and quantitative evaluations to the major system components. Results of this research can be extended to other applications in relevant areas. For instance, the proposed PCM thermal storage unit can be applied to integration with water-cooled conventional air-conditioning devices. Instead of using water cooling, a case study of using the proposed PCM unit for a water-cooled air-conditioner shows a COP increase of more than 25.6%.

  13. Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 2, Fluorescent lamp ballasts, television sets, room air conditioners, and kitchen ranges and ovens

    Energy Technology Data Exchange (ETDEWEB)

    1993-11-01

    This document is divided into ``volumes`` B through E, dealing with individual classes of consumer products. Chapters in each present engineering analysis, base case forecasts, projected national impacts of standards, life-cycle costs and payback periods, impacts on manufacturers, impacts of standards on electric utilities, and environmental effects. Supporting appendices are included.

  14. 高校地源热泵空调及生活热水系统设计浅析——以柳州医学高等专科学校新校区为例%On Design of Geothermal Heat Pump Air Conditioner and Domestic Hot Water System

    Institute of Scientific and Technical Information of China (English)

    刘国成; 陈捷

    2012-01-01

    通过工程实例,介绍地源热泵空调及生活热水系统的设计方法及要点,并对其先进性及难点进行了总结,供类似工程设计参考。%Through project case of Liuzhou Medical College, this paper introduces design of geothermal heat pump air conditioner and domestic hot water system for reference.

  15. 热泵空调器制热量衰减以及改善措施的研究%Research on Heating Attenuation about Heat Pump Air Conditioners and Improvements

    Institute of Scientific and Technical Information of China (English)

    刘志胜; 李凤凤; 杜京昌; 程德威

    2012-01-01

    热泵空调器在低温状况下制热能力下降得很快,有时候甚至不能制热。制热运行是一个逆卡诺循环过程,可以分为四个环节,要改善制热衰减问题,可以从这四个环节进行研究。在前人研究的基础上,通过建立数学模型并结合实验验证,总结出改善低温制热效果的几种措施。%Heat pump air conditioners heating ability at low temperature conditions reduced too quickly,and sometimes not even heating.Heating operation is a reverse Carnot cycle,it can be divided into four areas,you can study from the four areas to improve the system of thermal decay problem.The author,based on previous research,a mathematical model by combining with experiments,summarized several measures to improve low-temperature heating effect.

  16. 空调器铜管“蚁巢腐蚀”泄漏失效分析%Failure Analysis of"Nest Corrosion”Leakage of Air Conditioner's Copper Tube

    Institute of Scientific and Technical Information of China (English)

    2013-01-01

    This paper analyzed the “nest corrosion” leakage of air conditioner’s copper tube in details. It adopted the quantitative measurement for corrosion surface material through infrared spectrum, and the qualitative and quantitative testing for process and user’s envi-ronment corrosion materials. The method is accurate and feasible. The “nest corrosion” sub-stance concentration wave number and material was determined. Moreover, this paper also ful-filled the defend precautions for air conditioner.%  简介:对ACR(空调制冷)铜管“蚁巢腐蚀”泄漏失效实例进行了宏、微观泄漏特征分析确认。通过红外光谱法对腐蚀表面物质进行定量测量,及对加工工艺、用户环境腐蚀倾向物质进行定性定量测试,方法准确可行。确定了本次“蚁巢腐蚀”物质集中波数段及物质,也提供了可靠的高耐腐空调器防护措施。

  17. Application Prospects of High Strength Low-alloyed Steels to Sheet Metal of Air-conditioner%低合金高强度钢在空调钣金件中的应用前景

    Institute of Scientific and Technical Information of China (English)

    龙江; 蒋子琪

    2014-01-01

    本文主要介绍了低合金高强度钢的特点,从实际的加工性、防腐性和成本方面进行分析,并以某款家用空调器电机支架为例使用屈服强度在350MPa级的低合金高强度钢进行试验验证,结果表明低合金高强度钢在空调的钣金件加工中有较高的可行性和较好的应用前景%In the paper, The characteristics of high strength low-alloyed steels are mainly introduced.The actu-al machinability, corrosion resistance and cost are analyzed and the experimental verification have been taken by a certain motor support of high strength low-alloyed steels with yield strength of 350MPa level, it indicated that the high strength low-alloyed steels have higher feasibilities and more application prospects in sheet metal of air-conditioner.

  18. Measurement Innovation of Arc Chute Rail of Cabinet Air Conditioner Based on Three Coordinate Measuring Machine%基于三坐标测量机的柜式空调弧形滑槽轨道测量创新

    Institute of Scientific and Technical Information of China (English)

    占庆仲; 黄坚; 乔磊

    2015-01-01

    This paper mainly introduces the measurement innovation for arc chute rail of air guide mechanism of cabinet air conditioner. It uses the section curve uniform comb sampling fitting method and Germany Zeiss CMM programming automatic measurement mode, so as to realize the precision measurement of injection molding of an arc chute rail axis arc. According to the section curve uniform comb sampling fitting method, the application in similar geometric curve arc chute rail detection is discussed.%本文主要是对柜式空调导风机构的弧形滑槽轨道进行测量创新,采用截面曲线均布采点拟合测量方法,运用德国蔡司三坐标测量机编程自动测量方式,实现对注塑成型的弧形滑槽轨道中轴弧线直径的精密测量。针对截面曲线均布采点拟合测量方法进行梳理,探讨在类似几何曲线的滑槽轨道检测应用。

  19. Data center cooling system

    Energy Technology Data Exchange (ETDEWEB)

    Chainer, Timothy J; Dang, Hien P; Parida, Pritish R; Schultz, Mark D; Sharma, Arun

    2015-03-17

    A data center cooling system may include heat transfer equipment to cool a liquid coolant without vapor compression refrigeration, and the liquid coolant is used on a liquid cooled information technology equipment rack housed in the data center. The system may also include a controller-apparatus to regulate the liquid coolant flow to the liquid cooled information technology equipment rack through a range of liquid coolant flow values based upon information technology equipment temperature thresholds.

  20. 砂再生与砂冷却工艺装备的技术创新%The innovation of the sand regeneration and sand cooling process equipment

    Institute of Scientific and Technical Information of China (English)

    吴剑

    2015-01-01

    the paper introduces the casting process and the new development of the old sand regeneration and cooling process equipment technical characteristics. Sand regeneration, sand cooling and the application state of typical process equipment is analyzed. Provide process and technical support for the regeneration of foundry sand. Expand the development direction of the casting process equipment and production application.%介绍了近几年自硬砂工艺应用中新研发应用的旧砂再生、冷却工艺装备的技术特性.分析了自硬砂铸造工艺应用中砂再生、砂冷却及典型工艺装备的应用状态.为铸造业砂再生提供工艺及技术支持,拓展铸造工艺装备与生产应用的创新发展思路.

  1. 空调铝箔用高耐水性含氟丙烯酸疏水涂料的研制%Preparation of highly water-resistant fluoroacrylic hydrophobic coating for aluminum foils for air conditioner

    Institute of Scientific and Technical Information of China (English)

    聂建华; 周志盛; 霍泽荣

    2014-01-01

    A fluoroacrylic resin solution was synthesized by radical polymerization based on methyl methacrylate (MMA), butyl acrylate (BA), and stearyl acrylate (SA) as materials with 2-hydroxyethyl methacrylate (HEMA) as hydroxy functional monomer and fluorinated acrylate monomer as organic fluorine modifier, and then blended with curing agent to prepare a hydrophobic coating with high water resistance. The effects of different fluoroacrylate monomers on water contact angle and water dissolution rate of the coating were studied. The influence of the dosages of perfluoroalkyl ethyl methacrylate (PFMA) and HEMA on hydrophobicity and water resistance of the coating was discussed. The optimal reaction formulation was determined as follows: MMA 57%, BA 12%, SA 4%, PFMA 20%, and HEMA 7%. The coating prepared with the optimal formulation was characterized by Fourier transform infrared spectrometry,and tested for comparison of the comprehensive performance with a commercially available product. The results indicated that the coating has a water contact angle 132.7° and a water dissolution rate of 4.1%, being matchable to the comprehensive performance of the superhydrophobic coating formed from the Ultra AC series transparent vanish (a product of the Ultratech Ltd., USA, used for aluminum foils of air conditioner). The coating meets the requirement of surface treatment of aluminum foils for air conditioner.%以甲基丙烯酸甲酯(MMA)、丙烯酸丁酯(BA)以及丙烯酸十八酯(SA)为原料,甲基丙烯酸-β-羟乙酯(HEMA)为羟基功能单体,含氟丙烯酸酯单体为有机氟改性剂,通过溶液自由基聚合反应制备了含氟丙烯酸树脂溶液,再与固化剂配合使用制得高耐水性疏水涂膜。研究了不同含氟丙烯酸酯单体对涂膜的水接触角和水溶率的影响,讨论了甲基丙烯酸全氟烷基乙酯(PFMA)与HEMA不同用量对涂膜的疏水性和耐水性的影响,获得了最佳反应配方:MMA 57%,BA 12%,SA 4%

  2. Building technical services - Compact equipment for heating, hot water preparation, ventilation and cooling - Appendix; Haustechnik - Kompaktgeraete (Heizen, Warmwasser, Lueften, Kuehlen - alles aus einem). Erkenntnisse aus der Praxis - Anhang

    Energy Technology Data Exchange (ETDEWEB)

    Haessig, W.; Streit, S. [Haessig Sustech GmbH, Uster (Switzerland); Helfenfinger, D.; Keller, P. [Hochschule fuer Technik und Architektur Luzern (HSLU), Luzern (Switzerland)

    2009-06-15

    This comprehensive appendix to the final report for the Swiss Federal Office of Energy (SFOE) on compact equipment for heating, hot water preparation, ventilation and cooling presents detailed data on energy costs of the various apartments studied, as well as graphical representations of room temperatures and comfort, domestic hot water consumption, outdoor ambient temperatures and their influence on indoor temperatures for both summer and winter periods. System efficiency calculations and the methodologies used are described. Plans of the apartments that were examined complete this appendix.

  3. Lawrence Livermore National Laboratory (LLNL) Experimental Test Site (Site 300) Salinity Evaluation and Minimization Plan for Cooling Towers and Mechanical Equipment Discharges

    Energy Technology Data Exchange (ETDEWEB)

    Daily III, W D

    2010-02-24

    This document was created to comply with the Central Valley Regional Water Quality Control Board (CVRWQCB) Waste Discharge Requirement (Order No. 98-148). This order established new requirements to assess the effect of and effort required to reduce salts in process water discharged to the subsurface. This includes the review of technical, operational, and management options available to reduce total dissolved solids (TDS) concentrations in cooling tower and mechanical equipment water discharges at Lawrence Livermore National Laboratory's (LLNL's) Experimental Test Site (Site 300) facility. It was observed that for the six cooling towers currently in operation, the total volume of groundwater used as make up water is about 27 gallons per minute and the discharge to the subsurface via percolation pits is 13 gallons per minute. The extracted groundwater has a TDS concentration of 700 mg/L. The cooling tower discharge concentrations range from 700 to 1,400 mg/L. There is also a small volume of mechanical equipment effluent being discharged to percolation pits, with a TDS range from 400 to 3,300 mg/L. The cooling towers and mechanical equipment are maintained and operated in a satisfactory manner. No major leaks were identified. Currently, there are no re-use options being employed. Several approaches known to reduce the blow down flow rate and/or TDS concentration being discharged to the percolation pits and septic systems were reviewed for technical feasibility and cost efficiency. These options range from efforts as simple as eliminating leaks to implementing advanced and innovative treatment methods. The various options considered, and their anticipated effect on water consumption, discharge volumes, and reduced concentrations are listed and compared in this report. Based on the assessment, it was recommended that there is enough variability in equipment usage, chemistry, flow rate, and discharge configurations that each discharge location at Site 300

  4. 转速可控型房间空调器用压缩机能效评价方法研究及应用%Analysis and Application of Evaluation Method on Compressors for Variable Speed Room Air Conditioners

    Institute of Scientific and Technical Information of China (English)

    张海锋; 吴建华; 厉彦忠

    2013-01-01

    The efficiency requirement of room air conditioner (RAC) has became stricter and stricter with the development of global environment consciousness. The efficiency evaluation method of RAC has been updated from single working condition to aunnal performance factor (APF) with multiple working condition. Performance evaluation method of compressors must be changed accordingly which account for main energy consumption of RAC. Compressor efficiency of annual performance (COAP) is proposed to evaluate the efficiency level of inverter compressor which is applied in variable speed RAC with multiple working conditions. Actual operation efficiency can be indicated by COAP because inverter compressor performance is considered according to COAP. In order to simplify test procedure of COAP, standard test conditions and its weight are generated .Then the effect of efficiency curve of inverter compressor on COAP is discussed . Finally examples with this method are illustrated for compressor matching and design optimization.%  随着全球环境保护意识的加强,家用空调能耗水平不断增高,房间空调器能效评价方法已从单工况向全年运行效率(APF)转变。压缩机作为空调器中的主要耗能部件,其能效评价方法也要随之变化。这里提出了变速压缩机全年综合能效比指标--COAP来衡量压缩机在全年变工况条件下的运行效率,此指标综合考虑了变速压缩机全年运行的能效情况,能客观反映压缩机在不同气候条件下实际运行效率。为简化测试COAP,给出了COAP基准工况及各工况权重,讨论了压缩机效率曲线对COAP的影响,最后通过举例说明如何利用COAP进行压缩机选型及设计优化。

  5. Pulmonary function tests in air conditioner users

    African Journals Online (AJOL)

    McRoy

    2014-07-26

    Jul 26, 2014 ... 1Department of Physiology, Kamineni Academy of Medical Sciences and Research Centre,. L.B.Nagar ... for Sight, Banjara Hills, Hyderabad, Andhra Pradesh, India. ... Background: Modernization has been implicated in the ...

  6. Application of Pro/ENGINEER pipe feature in air conditioner pipeline design and the method of bend dimensions%Pro/ENGINEER管道特征在空调管路设计中的应用及弯管尺寸标注方法

    Institute of Scientific and Technical Information of China (English)

    刘明校; 肖云龙; 宗颖超; 钟光明; 陈伟; 高德锁

    2011-01-01

    According to the vector tube bending principle of the CNC pipe bender,use Pro/ENGINEER pipe feature for 3D modeling of air conditioner pipeline and 2D projection conversion,In combination with the CNC pipe bender program features, propose a reasonable way of bend dimensioning in order to facilitate Programming for the production process and parts inspection,reduce the number of test bends,to achieve productivity gains and production costs of the air-conditioner pipe fittings.%根据数控弯管机矢量弯管原理,利用Pro/ENGINEER管道特征对空调器管路进行3D建模以及2D投影图转换,并结合数控弯管机的弯管程序特性,提出一种合理的弯管尺寸标注方式,以便于生产过程中程序的编制及零件的检验,减少试弯次数,从而实现空调器管件的生产效率提高及生产成本降低.

  7. A comparison of R 407C and R 410A with R 22 in a 10.5 kW central air conditioner for residential buildings; Vergleich von R 407C und R 410A mit R22 in einer Zentralklimaanlage fuer Wohnhaeuser mit 10,5 kW Leistung

    Energy Technology Data Exchange (ETDEWEB)

    Linton, J.W. [National Research Council Canada (NRC), Ottawa, ON (Canada); Snelson, W.K. [National Research Council Canada (NRC), Ottawa, ON (Canada); Hearty, P.F. [National Research Council Canada (NRC), Ottawa, ON (Canada); Murphy, F.T. [ICI Klea, New Castle, DE (United States); Low, R.E. [ICI Klea, New Castle, DE (United States); Gilbert, B.E. [ICI Klea, New Castle, DE (United States)

    1996-02-01

    Details are given about comparative performance tests (compressor capacity, evaporator capacity, refrigerant mass flow, refrigerating capacity) of a 10.5 kW central residential air conditioner run on the long-time refrigerant substitutes R 407C and R 410A and on R 22. Efficiency improvement potentials were assessed by adapting the evaporator of the air conditioner to the properties of R 407C through a change in direction of the air flow that was brought about by reversing the evaporator coil. (BWI) [Deutsch] In einer Zentralklimaanlage fuer Wohnhaeuser mit einer Leistung von 10,5 kW wurde eine Leistungsmessung der beiden langfristigen Ersatzstoffe R407C und R410A im Vergleich zu R22 durchgefuehrt. Die gemessenen Leistungsdaten waren Verdichterleistung, Verdampferleistung, Kaeltemittelmassenstrom und Kaelteleistungszahl (COP). Um Bereiche ausfindig zumachen, in denen die Effizienz verbessert werden koennte, wurde der Verdampfer der Klimaanlage zur Anpassung an die Eigenschaften von R407C teiloptimiert (Aenderung der Richtung des Luftstroms durch Umdrehung der Verdampferspule). (BWI)

  8. 变径毛细管代替毛细管组件在冷暖空调器上的应用研究%Experimental Investigation on Thermal Properties of Heat pump Air-conditioner with Variable Diameter Capillary Instead of Capillary Module

    Institute of Scientific and Technical Information of China (English)

    徐言生; 何钦波; 黎绵昌; 邹时智; 金波

    2013-01-01

    The refrigerant flow characteristics of variable diameter capillary in forward flow and reverse flow are different. It can be used as a throttle device instead of the capillary module in heat pump air-conditioner. To achieve this goal, the refrigerant flow characteristic of the original capillary module for refrigerating and heating circulation was performed in the refrigerant flow experimental facility. The size of variable diameter capillary was adjusted to make its refrigerant flow performance is accordance with that of capillary module. The capability of air conditioner with variable diameter capillary and capillary module were tested respectively in the standard condition. The experimental results show that the performance of air-conditioner with variable diameter capillary compared to that of air conditioner with capillary module, the refrigerating capacity decreased by 0.5% , the energy efficiency ratio(EER) increased by 0. 3% , the heating capacity reduced by 1. 1% , the coefficient of performance ( COP) increased by 1.4%. Hence, the higher flow performances of variable diameter capillary indicate that it can completely used as a throttle device instead of the capillary module in the heat pump air-conditioner after it matched exactly.%变径毛细管在正向流动和反向流动时其制冷剂流量特性不同,因而可以作为节流元件代替现有冷暖空调器中使用的毛细管组件.为实现这一目的,利用制冷剂流量试验台,先测定原毛细管组件制冷、制热时的制冷剂流量特性,然后通过调整变径毛细管规格尺寸,使变径毛细管制冷、制热时的流量特性与原毛细管组件基本一致,再安装在空调器整机上进行整机性能对比试验.试验表明,在标准工况下,新空调器与原空调器相比,其制冷量减少0.5%,制冷能效比增加0.3%,制热量减少1.1%,制热性能系数增加1.4%.因此可以得出,变径毛细管经过精确匹配,完全可以作为节流

  9. Methodology of Supervision by Analysis of Thermal Flux for Thermal Conduction of a Batch Chemical Reactor Equipped with a Monofluid Heating/Cooling System

    Directory of Open Access Journals (Sweden)

    Ghania Henini

    2012-01-01

    Full Text Available We present the thermal behavior of a batch reactor to jacket equipped with a monofluid heating/cooling system. Heating and cooling are provided respectively by an electrical resistance and two plate heat exchangers. The control of the temperature of the reaction is based on the supervision system. This strategy of management of the thermal devices is based on the usage of the thermal flux as manipulated variable. The modulation of the monofluid temperature by acting on the heating power or on the opening degrees of an air-to-open valve that delivers the monofluid to heat exchanger. The study shows that the application of this method for the conduct of the pilot reactor gives good results in simulation and that taking into account the dynamics of the various apparatuses greatly improves ride quality of conduct. In addition thermal control of an exothermic reaction (mononitration shows that the consideration of heat generated in the model representation improve the results by elimination any overshooting of the set-point temperature.

  10. Performance and evaluation of gas engine driven rooftop air conditioning equipment at the Willow Grove (PA) Naval Air Station. Interim report, 1992 cooling season

    Energy Technology Data Exchange (ETDEWEB)

    Armstrong, P.R.; Conover, D.R.

    1993-05-01

    In a field evaluation conducted for the US Department of Energy (DOE) Office of Federal Energy Management Program (FEMP), the Pacific Northwest Laboratory (PNL) examined the performance of a new US energy-related technology under the FEMP Test Bed Demonstration Program. The technology was a 15-ton natural gas engine driven roof top air conditioning unit. Two such units were installed on a naval retail building to provide space conditioning to the building. Under the Test Bed Demonstration Program, private and public sector interests are focused to support the installation and evaluation of new US technologies in the federal sector. Participating in this effort under a Cooperative Research and Development Agreement (CRADA) with DOE were the American Gas Cooling Center, Philadelphia Electric Company, Thermo King Corporation, and the US Naval Air Station at Willow Grove, Pennsylvania. Equipment operating and service data as well as building interior and exterior conditions were secured for the 1992 cooling season. Based on a computer assessment of the building using standard weather data, a comparison was made with the energy and operating costs associated with the previous space conditioning system. Based on performance during the 1992 cooling season and adjusted to a normal weather year, the technology will save the site $6,000/yr in purchased energy costs. An additional $9,000 in savings due to electricity demand ratchet charge reductions will also be realized. Detailed information on the technology, the installation, and the results of the technology test are provided to illustrate the advantages to the federal sector of using this technology. A history of the CRADA development process is also reported.

  11. Optimal Design of a Thermoelectric Cooling/Heating System for Car Seat Climate Control (CSCC)

    Science.gov (United States)

    Elarusi, Abdulmunaem; Attar, Alaa; Lee, Hosung

    2016-12-01

    In the present work, the optimum design of thermoelectric car seat climate control (CSCC) is studied analytically in an attempt to achieve high system efficiency. Optimal design of a thermoelectric device (element length, cross-section area and number of thermocouples) is carried out using our newly developed optimization method based on the ideal thermoelectric equations and dimensional analysis to improve the performance of the thermoelectric device in terms of the heating/cooling power and the coefficient of performance (COP). Then, a new innovative system design is introduced which also includes the optimum input current for the initial (transient) startup warming and cooling before the car heating ventilation and air conditioner (HVAC) is active in the cabin. The air-to-air heat exchanger's configuration was taken into account to investigate the optimal design of the CSCC.

  12. Optimal Design of a Thermoelectric Cooling/Heating System for Car Seat Climate Control (CSCC)

    Science.gov (United States)

    Elarusi, Abdulmunaem; Attar, Alaa; Lee, Hosung

    2017-04-01

    In the present work, the optimum design of thermoelectric car seat climate control (CSCC) is studied analytically in an attempt to achieve high system efficiency. Optimal design of a thermoelectric device (element length, cross-section area and number of thermocouples) is carried out using our newly developed optimization method based on the ideal thermoelectric equations and dimensional analysis to improve the performance of the thermoelectric device in terms of the heating/cooling power and the coefficient of performance (COP). Then, a new innovative system design is introduced which also includes the optimum input current for the initial (transient) startup warming and cooling before the car heating ventilation and air conditioner (HVAC) is active in the cabin. The air-to-air heat exchanger's configuration was taken into account to investigate the optimal design of the CSCC.

  13. Application of Heat Pipe Technique in Satellite Earth Station Cooling%热管技术在卫星地面站高功放散热中的应用

    Institute of Scientific and Technical Information of China (English)

    宁业强; 罗雪松; 周军; 宋忠波; 王洪林

    2015-01-01

    本文以CPI GENIV3kW速调管散热遇到的问题为着眼点,介绍了不良空气质量影响CPI GENIV3kW速调管运行稳定性和寿命的解决办法。CPI GENIV3kW速调管功放风冷空气经过所有的高压电极,高湿度、含有各种悬浮颗粒物以及污染物的空气严重影响设备的稳定运行和使用寿命,导致维护难度高,维护保养中断时间长;鉴于设备运行空间受限和运行耗能大,基于传统空气过滤方法的强制风冷、以及基于空调制冷的机房内循环风冷,都难以兼顾既节能又较好保障速调管安全运行的目的;热管换热系统能效比最高可达15年以上,极其适用于那些局部温度远远高于室外,而且因为室外环境的粉尘和空气污染无法敞开式散热的环境。%This article focuses on CPI GENIV3kW klystron amplifier cooling, introducing the solution of preventing bad air damaging CPI GENIV3kW klystron amplifier’s stability and life. CPI GENIII and the early klystron amplifier were less affected by air, since cold air only worked on cooling fins. However, when using GENIV3kW klystron, cold air blows over all the high voltage electrodes. The high-salt, high-humidity, dusty air severely impacts the stability and life of equipments, causing many difficulties to maintenance. Due to the limitation of equipment operation space and high power dissipation, traditional air-forced cooling and air-conditioner cooling could not be both energy efficient and safe. Heat pipe system’s EER (energy efficiency ratio) can go up to 15 and above, therefore, is extremely appropriate for those thermal environments whose local temperature is highly above outdoor temperature and cannot be open because of the dust outside.

  14. Legionella safety in cooling towers; Legionellaveiligheid in koeltorens

    Energy Technology Data Exchange (ETDEWEB)

    Kordes, B. [Kordes Advies, (Netherlands); De Bok, F. [KBBL Wijhe, (Netherlands); De Zeeuw, L. [Holland Environment Group, (Netherlands); Settels, P. [Safety, Health Services and Ergonomics, ING, (Netherlands); Oesterholt, F.; Wullings, B. [KWR Watercycle Research Institute, (Netherlands); Guiot, P. [Tevan, Gorinchem (Netherlands); Brands, R. [Cumulus Nederland, Cuijk (Netherlands); Nuijten, O. [Kennisinstituut ISSO, Rotterdam (Netherlands); Wijne, R. [Beer advocaten, Amsterdam (Netherlands)

    2010-04-15

    In 9 articles attention is paid to several aspects with regard to Legionella in cooling towers: representative sampling, the use of copper and silver ionization or hydrogen peroxide to prevent Legionella growth and biofilms, the use of a zero-tolerance model to control a cooling tower installation, detection of DNA of Legionella Pneumophila, legionella safety in air conditioners, the model Legionella risk analysis and control of cooling tower installations, legislation and regulations for the control of cooling tower installations with regard to the Dutch Occupational Health and Safety Act ('Arbo-wet'), and an article about a lawsuit for victims of a Legionella outbreak, caused by careless owners of a cooling tower in Amsterdam, Netherlands. [Dutch] In 9 artikelen wordt in deze aflevering aandacht besteed aan verschillende aspecten m.b.t. Legionella in koeltorens: representatieve monstername, de toepassing van koper en zilver-ionisatie of waterstofperoxide om de groei van Legionella en biofilms te voorkomen, het gebruik van een zero-tolerance model om een koeltoren installatie te controleren, detectie van DNA van Legionella Pneumophila, Legionella veiligheid in luchtbehandelingsinstallaties, het model Legionella risicoanalyse en beheersplan voor koeltoreninstallaties, de rol van de Arbo-wet, en een artikel over een rechtszaak voor slachtoffers van Legionella door onzorgvuldig beheer van een koeltoren in Amsterdam.

  15. Performance test of solar-assisted ejector cooling system

    KAUST Repository

    Huang, Bin-Juine

    2014-03-01

    A solar-assisted ejector cooling/heating system (SACH-2k) is built and test result is reported. The solar-driven ejector cooling system (ECS) is connected in series with an inverter-type air conditioner (IAC). Several advanced technologies are developed in SACH-k2, including generator liquid level control in ECS, the ECS evaporator temperature control, and optimal control of fan power in cooling tower of ECS. From the field test results, the generator liquid level control performs quite well and keeps stable performance of ejector. The ECS evaporator temperature control also performs satisfactorily to keep ejector performance normally under low or fluctuating solar radiation. The fan power control system cooling tower performs stably and reduces the power consumption dramatically without affecting the ECS performance. The test results show that the overall system COPo including power consumptions of peripheral increases from 2.94-3.3 (IAC alone) to 4.06-4.5 (SACH-k2), about 33-43%. The highest COPo is 4.5. © 2013 Elsevier Ltd and IIR. All rights reserved.

  16. Initial operation of a solar heating and cooling system in a full-scale solar building test facility

    Science.gov (United States)

    Knoll, R. H.; Miao, D.; Hamlet, I. L.; Jensen, R. N.

    1976-01-01

    The Solar Building Test Facility (SBTF) located at Hampton, Virginia became operational in early summer of 1976. This facility is a joint effort by NASA-Lewis and NASA-Langley to advance the technology for heating and cooling of office buildings with solar energy. Its purposes are to (1) test system components which include high-performing collectors, (2) test performance of complete solar heating and cooling system, (3) investigate component interactions and (4) investigate durability, maintenance and reliability of components. The SBTF consists of a 50,000 square foot office building modified to accept solar heated water for operation of an absorption air conditioner and for the baseboard heating system. A 12,666 square foot solar collector field with a 30,000 gallon storage tank provides the solar heated water. A description of the system and the collectors selected is given here, along with the objectives, test approach, expected system performance and some preliminary results.

  17. Data center cooling method

    Energy Technology Data Exchange (ETDEWEB)

    Chainer, Timothy J.; Dang, Hien P.; Parida, Pritish R.; Schultz, Mark D.; Sharma, Arun

    2015-08-11

    A method aspect for removing heat from a data center may use liquid coolant cooled without vapor compression refrigeration on a liquid cooled information technology equipment rack. The method may also include regulating liquid coolant flow to the data center through a range of liquid coolant flow values with a controller-apparatus based upon information technology equipment temperature threshold of the data center.

  18. Technical Subtopic 2.1: Modeling Variable Refrigerant Flow Heat Pump and Heat Recovery Equipment in EnergyPlus

    Energy Technology Data Exchange (ETDEWEB)

    Raustad, Richard; Nigusse, Bereket; Domitrovic, Ron

    2013-09-30

    enthalpy method where relevant air-side parameters were controlled while collecting output performance data at discreet points of steady-state operation. The primary metrics include system power consumption and zonal heating and cooling capacity. Using this test method, the measured total cooling capacity was somewhat lower than reported by the manufacturer. The measured power was found to be equal to or greater than the manufacturers indicated power. Heating capacity measurements produced similar results. The air-side performance metric was total cooling and heating energy since the computer model uses those same metrics as input to the model. Although the sensible and latent components of total cooling were measured, they are not described in this report. The test methodology set the thermostat set point temperature very low for cooling and very high for heating to measure full-load performance and was originally thought to provide the maximum available capacity. Manufacturers stated that this test method would not accurately measure performance of VRF systems which is now believed to be a true statement. Near the end of the project, an alternate test method was developed to better represent VRF system performance as if field installed. This method of test is preliminarily called the Load Based Method of Test where the load is fixed and the indoor conditions and unit operation are allowed to fluctuate. This test method was only briefly attempted in a laboratory setting but does show promise for future lab testing. Since variable-speed air-conditioners and heat pumps include an on-board control algorithm to modulate capacity, these systems are difficult to test. Manufacturers do have the ability to override internal components to accommodate certification procedures, however, it is unknown if the resulting operation is replicated in the field, or if so, how often. Other studies have shown that variable-speed air-conditioners and heat pumps do out perform their single

  19. An experimental investigation of supercritical heat transfer in a three-rod bundle equipped with wire-wrap and grid spacers and cooled by carbon dioxide

    Energy Technology Data Exchange (ETDEWEB)

    Eter, Ahmad, E-mail: eng.eter@yahoo.com; Groeneveld, Dé, E-mail: degroeneveld@gmail.com; Tavoularis, Stavros, E-mail: stavros.tavoularis@uottawa.ca

    2016-07-15

    Highlights: • Heat transfer at supercritical pressures was studied experimentally in a three-rod bundle equipped with wire-wrap spacers or grid spacers. • Heat transfer deterioration occurred near the heated inlet under certain conditions. • Normal heat transfer was generally comparable to that in a tube and the predictions of a correlation. - Abstract: Heat transfer measurements in a three-rod bundle equipped with wire-wrap and grid spacers were obtained at supercritical pressures in the Supercritical University of Ottawa Loop (SCUOL). The tests were performed using carbon dioxide, as a surrogate fluid for water, flowing upwards for wide ranges of conditions, including conditions equivalent to the nominal and near-normal operating conditions of the proposed Canadian Super-Critical Water-Cooled Reactor. The test section contained three heated rods and three unheated rod segments with an outer diameter of 10 mm and a pitch-to-diameter ratio of 1.14; the heated length was 1500 mm. Detailed surface temperature measurements along and around the three heated rods were collected using internally traversed thermocouples. The following ranges of test conditions were covered, with equivalent water conditions given inside parentheses: pressure from 6.6 to 8.36 MPa (19.7–25 MPa); inlet temperature from 11 to 30 °C (330–371 °C); mass flux from 200 to 1175 kg m{sup −2} s{sup −1} (340–1822 kg m{sup −2} s{sup −1}); and wall heat flux from 1 to 175 kW m{sup −2} (11–1847 kW m{sup −2}). For one set of tests, the heated rods were fitted with a 1.3 mm OD wire wrap, having an axial pitch of 200 mm along the entire heated length; for a second set, the heated rods were fitted with grid spacers having a 5.3% flow blockage and located at 500 mm axial intervals. The effects of spacer configuration on heat transfer at supercritical pressures were documented and analyzed. The observed experimental trends were compared to those obtained in a experiment in a heated

  20. Optimization operation analysis on energy-saving & consumption reduction of air cooling equipment in ethylene plant%乙烯装置空冷设备节能降耗优化操作分析

    Institute of Scientific and Technical Information of China (English)

    刘传云; 李海波

    2015-01-01

    In the existing cooling equipment of ethylene plant,field staffs has a high randomness in the operation of air cooling equipment,and has not achieved fine management. With the air cooling equipment of an ethylene cracking plant as an example,grids were established by using Gambit,and air flow pattern calculation was made by using Fluent to get the best heat exchange condition. They were used to guide the field staffs in actual operation,and the goal of plant energy saving and consumption reduction was achieved.%在现行的乙烯装置空冷设备中,现场人员对空冷的操作上随意性比较大,没有做到精细化管理。文中以某乙烯裂解装置的空冷设备为例,通过Gambit建立网格,再利用Fluent进行空气流动形态计算得到最佳的换热状态,用于指导现场人员实际操作,达到装置节能降耗的目的。

  1. Optimal control and performance test of solar-assisted cooling system

    KAUST Repository

    Huang, B.J.

    2010-10-01

    The solar-assisted cooling system (SACH) was developed in the present study. The ejector cooling system (ECS) is driven by solar heat and connected in parallel with an inverter-type air conditioner (A/C). The cooling load can be supplied by the ECS when solar energy is available and the input power of the A/C can be reduced. In variable weather, the ECS will probably operate at off-design condition of ejector and the cooling capability of the ECS can be lost completely. In order to make the ejector operate at critical or non-critical double-choking condition to obtain a better performance, an electronic expansion valve was installed in the suction line of the ejector to regulate the opening of the expansion valve to control the evaporator temperature. This will make the SACH always produce cooling effect even at lower solar radiation periods while the ejector performs at off-design conditions. The energy saving of A/C is experimentally shown 50-70% due to the cooling performance of ECS. The long-term performance test results show that the daily energy saving is around 30-70% as compared to the energy consumption of A/C alone (without solar-driven ECS). The total energy saving of A/C is 52% over the entire test period. © 2010 Elsevier Ltd. All rights reserved.

  2. Environmental assessment. Energy efficiency standards for consumer products

    Energy Technology Data Exchange (ETDEWEB)

    McSwain, Berah

    1980-06-01

    The Energy Policy and Conservation Act of 1975 requires DOE to prescribe energy efficiency standards for 13 consumer products. The Consumer Products Efficiency Standards (CPES) program covers: refrigerators and refrigerator-freezers, freezers, clothes dryers, water heaters, room air conditioners, home heating equipment, kitchen ranges and ovens, central air conditioners (cooling and heat pumps), furnaces, dishwashers, television sets, clothes washers, and humidifiers and dehumidifiers. This Environmental Assessment evaluates the potential environmental and socioeconomic impacts expected as a result of setting efficiency standards for all of the consumer products covered by the CPES program. DOE has proposed standards for eight of the products covered by the Program in a Notice of Proposed Rulemaking (NOPR). DOE expects to propose standards for home heating equipment, central air conditioners (heat pumps only), dishwashers, television sets, clothes washers, and humidifiers and dehumidifiers in 1981. No significant adverse environmental or socioeconomic impacts have been found to result from instituting the CPES.

  3. Simulated performance of CIEE's 'Alternatives to Compressive Cooling' prototype house under design conditions in various California climates

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Yu Joe

    1999-12-01

    To support the design development of a compressorless house that does not rely on mechanical air-conditioning, the author carried out detailed computer analysis of a prototypical house design to determine the indoor thermal conditions during peak cooling periods for over 170 California locations. The peak cooling periods are five-day sequences at 2{percent} frequency determined through statistical analysis of long-term historical weather data. The DOE-2 program was used to simulate the indoor temperatures of the house under four operating options: windows closed, with mechanical ventilation, evaporatively-cooled mechanical ventilation, or a conventional 1 1/2-ton air conditioner. The study found that with a 1500 CFM mechanical ventilation system, the house design would maintain comfort under peak conditions in the San Francisco Bay Area out to Walnut Creek, but not beyond. In southern California, the same system and house design would maintain adequate comfort only along the coast. With the evaporatively-cooled ventilation system, the applicability of the house design can be extended to Fairfield and Livermore in northern California, but in southern California a larger 3000 CFM system would be needed to maintain comfort conditions over half of the greater Los Angeles area, the southern half of the Inland Empire, and most of San Diego county. With the 1 1/2-ton air conditioner, the proposed house design would perform satisfactorily through most of the state, except in the upper areas of the Central Valley and the hot desert areas in southern California. In terms of energy savings, the simulations showed that the prototypical house design would save from 0.20 to 0.43 in northern California, 0.20 to 0.53 in southern California, and 0.16 to 0.35 in the Central Valley, the energy used by the same house design built to Title-24 requirements.

  4. Experimental investigation of the influence of the air jet trajectory on convective heat transfer in buildings equipped with air-based and radiant cooling systems

    DEFF Research Database (Denmark)

    Le Dreau, Jerome; Heiselberg, Per; Jensen, Rasmus Lund

    2015-01-01

    The complexity and diversity of airflow in buildings make the accurate definition of convective heat transfer coefficients (CHTCs) difficult. In a full-scale test facility, the convective heat transfer of two cooling systems (active chilled beam and radiant wall) has been investigated under steady......-state and dynamic conditions. With the air-based cooling system, a dependency of the convective heat transfer on the air jet trajectory has been observed. New correlations have been developed, introducing a modified Archimedes number to account for the air flow pattern. The accuracy of the new correlations has been...... evaluated to±15%. Besides the study with an air-based cooling system, the convective heat transfer with a radiant cooling system has also been investigated. The convective flow at the activated surface is mainly driven by natural convection. For other surfaces, the complexity of the flow and the large...

  5. 循环冷却水换热设备腐蚀研究综述%Reviews of Research on Corrosion of Heat Exchanger Equipment in Circulating Cooling Water

    Institute of Scientific and Technical Information of China (English)

    齐晓辉; 孙玲玲; 刘秀伟

    2014-01-01

    本文对循环冷却水换热设备腐蚀机制及分类进行了简要的概述。综述了近几年国内外循环冷却水换热设备腐蚀特性的研究进展,主要表现在冷却水腐蚀监测、预测和防腐对策3个方向上。综合已有的研究成果,提出了结合现场水质参数与腐蚀速率实测数据进行腐蚀特性预测,并应用电磁物理法与其它腐蚀防护技术协同作用这一研究新方向。%In this paper, the corrosion mechanism of circulating cooling water heat exchanger equipment and its classification are briefly introduced. Progress in corrosion properties of circulating cooling water heat exchanger equipment at home and abroad in recent years is reviewed, mainly in three directions of the cooling water corrosion monitoring, forecasting and corrosion countermeasure. Based on the current research status, a new research on combining on-site water quality parameters and corrosion rate measured data to predict corrosion characteristics, and application of the physical method of electromagnetic corrosion and other corrosion protection technology together is proposed.

  6. Not-In-Kind Technologies for Residential and Commercial Unitary Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, S.K.

    2001-01-11

    maintenance costs although energy use would be higher. There are strong opportunities for gas-fired heat pumps to reduce both energy use and operating costs outside of the high cooling climates in the southeast, south central states, and the southwest. Diesel and IC (Otto) engine-driven heat pumps are commercially available and should be able to increase their market share relative to gas furnaces on a life cycle cost basis; the cost premiums associated with these products, however, make it difficult to achieve three or five year paybacks which adversely affects their use in the U.S. Stirling engine-driven and duplex Stirling heat pumps have been investigated in the past as potential gas-fired appliances that would have longer lives and lower maintenance costs than diesel and IC engine-driven heat pumps at slightly lower efficiencies. These potential advantages have not been demonstrated and there has been a low level of interest in Stirling engine-driven heat pumps since the late 1980's. GAX absorption heat pumps have high heating efficiencies relative to conventional gas furnaces and are viable alternatives to furnace/air conditioner combinations in all parts of the country outside of the southeast, south central states, and desert southwest. Adsorption heat pumps may be competitive with the GAX absorption system at a higher degree of mechanical complexity; insufficient information is available to be more precise in that assessment.

  7. Optimal replacement of residential air conditioning equipment to minimize energy, greenhouse gas emissions, and consumer cost in the US

    Energy Technology Data Exchange (ETDEWEB)

    De Kleine, Robert D. [Center for Sustainable Systems, School of Natural Resources and Environment, University of Michigan, 440 Church St., Dana Bldg., Ann Arbor, MI 48109-1041 (United States); Keoleian, Gregory A., E-mail: gregak@umich.edu [Center for Sustainable Systems, School of Natural Resources and Environment, University of Michigan, 440 Church St., Dana Bldg., Ann Arbor, MI 48109-1041 (United States); Kelly, Jarod C. [Center for Sustainable Systems, School of Natural Resources and Environment, University of Michigan, 440 Church St., Dana Bldg., Ann Arbor, MI 48109-1041 (United States)

    2011-06-15

    A life cycle optimization of the replacement of residential central air conditioners (CACs) was conducted in order to identify replacement schedules that minimized three separate objectives: life cycle energy consumption, greenhouse gas (GHG) emissions, and consumer cost. The analysis was conducted for the time period of 1985-2025 for Ann Arbor, MI and San Antonio, TX. Using annual sales-weighted efficiencies of residential CAC equipment, the tradeoff between potential operational savings and the burdens of producing new, more efficient equipment was evaluated. The optimal replacement schedule for each objective was identified for each location and service scenario. In general, minimizing energy consumption required frequent replacement (4-12 replacements), minimizing GHG required fewer replacements (2-5 replacements), and minimizing cost required the fewest replacements (1-3 replacements) over the time horizon. Scenario analysis of different federal efficiency standards, regional standards, and Energy Star purchases were conducted to quantify each policy's impact. For example, a 16 SEER regional standard in Texas was shown to either reduce primary energy consumption 13%, GHGs emissions by 11%, or cost by 6-7% when performing optimal replacement of CACs from 2005 or before. The results also indicate that proper servicing should be a higher priority than optimal replacement to minimize environmental burdens. - Highlights: > Optimal replacement schedules for residential central air conditioners were found. > Minimizing energy required more frequent replacement than minimizing consumer cost. > Significant variation in optimal replacement was observed for Michigan and Texas. > Rebates for altering replacement patterns are not cost effective for GHG abatement. > Maintenance levels were significant in determining the energy and GHG impacts.

  8. Thermical Load Calculation and Capacity of Cooling and Venting Equipment of a Diesel Engine Emissions Study Bench; Calculo de Cargas Termicas y Capacidad de los Equipos de Refrigeracion y Ventilacion de un Banco de Estudio de Emisiones de Motores Diesel

    Energy Technology Data Exchange (ETDEWEB)

    Rojas Garcia, E.; Fonseca Gonzalez, N. A.

    2005-07-01

    The present report tries to develop the calculation of thermical loads and to define the capacity of the equipments of cooling and ventilation that should have the engines test bench that is being ensemble in the installation of the CIEMAT named {sup D}iesel engine emissions study bench (E65-P0). The test bench is formed essentially by a dynamometrical brake and an engine connected at previous one, both of them inside a cabin of isolation acoustic. The thermical loads to be dissipated will be calculated for all the elements that compose the bench and considering his maximum values, to determine the suitable system of cooling air - water of the devices and ventilation in the cabin. (Author) 2 refs.

  9. Study of Controller for the Frequency Conversion Air Conditioner with Micro-controller MC68HC908MR16%基于MC68HC908MR16单片机的变频空调控制器的研究

    Institute of Scientific and Technical Information of China (English)

    刘永; 干练

    2012-01-01

    针对变频空调器的特点,应用具有电机控制模块的单片机MC68HC908MR16设计了空调专用变频控制器,给出了变频空调控制器的系统结构原理图,以及空间矢量调制技术的单片机实现原理.该变频控制器采用空间矢量调制技术,提高了电源利用率和压缩机的低频转矩.%According to the characteristics on the use of air conditioners, a specific inverter is designed based on the MC68HC908MR16. The schematic circuit of the inverter and the principle of SVM achieved with MCU are given. The (SVM) is adopted,which is helpful for increasing the power utilization and low speed torque of the compressors.

  10. Building technical services - Compact equipment for heating, hot water preparation, ventilation and cooling - Final report; Haustechnik - Kompaktgeraete (Heizen, Warmwasser, Lueften, Kuehlen - alles aus einem). Erkenntnisse aus der Praxis - Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Haessig, W.; Streit, S. [Haessig Sustech GmbH, Uster (Switzerland); Helfenfinger, D.; Keller, P. [Hochschule fuer Technik und Architektur Luzern (HSLU), Luzern (Switzerland)

    2009-06-15

    This comprehensive final report for the Swiss Federal Office of Energy (SFOE) presents and discusses the knowledge gained in practice concerning compact equipment that can be used for heating, hot water preparation, ventilation and cooling. Such units combine heat-pumps and the further equipment necessary. Data on various factors were collected over a period of one year in three apartment blocks that meet Swiss Minergie-P very low energy consumption standards. Apart from the above mentioned factors, the study also considered humidity and carbon dioxide levels in the apartments and inhabitant behaviour. The authors note that the energy consumption of several apartments fell below the Minergie-P limiting, annual value of 30 kWh/m2. An increase in electricity consumption dependent on room temperatures is noted and commented on. The economic feasibility of Minergie-P and so-called passive housing is commented on.

  11. Energy efficiency program through exchange of air conditioners in residential sector of Manaus city: a concrete experience; Programa de eficiencia energetica atraves da troca de condicionadores de ar no setor residencial de Manaus: uma experiencia concreta

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Fabricio Rodrigues; Goncalves, Ana Catarina Lima Chaves; Cartaxo, Elizabeth Ferreira; Gomes, Hugo Miguel Oliveira; Nascimento, Nilton Correa; Inui, Raul Eiji; Guedes, Ricardo Augusto de Morais; Benchaya, Roberto Tavares [Universidade Federal do Amazonas (UFAM), Manaus, AM (Brazil)

    2004-07-01

    The present review attempts to evaluate the importance of efficient equipment diffusion in reducing energy consumption, based upon the Study-case of an air conditioned exchange program in Manaus city of Amazonas. In spite of the existence, in the actual market, of efficient technology, it has been, yet, badly diffused, mostly due to economical and informative laps. Therefore, once tried to demonstrate the potential benefits, in technical gains, of energy efficiency offered by efficient Air conditioned equipment, through a plan that favors the consumer's participation as an active contributor in the dissemination process of efficient technology, and a following program for efficiency evaluation, beside a tributary evaluation proposal, so that technology becomes accessible to the general population, attempting its benefices. In addition, the environmental benefits of that specific proposal are analyzed, trough the developed recycling program. (author)

  12. With cooling and double floor. Clima-Tect for cable bushing ensures air conditioning of servers; Mit Kuehlung und doppeltem Boden. Clima-Tect fuer Kabeldurchfuehrungen sichert Server-Klimatisierung

    Energy Technology Data Exchange (ETDEWEB)

    Gassel, Christine

    2011-04-15

    While data centers are growing worldwide, their energy requirements and thus their cost also increase. Nearly twelve percent of the total expenditure now went to electricity as shown by new calculations of the IT market research institute Gartner Inc. (Munich, Federal Republic of Germany). According to the analysts, just 35 to 50 percent of this flow into the server cooling. Thus, although the air conditioners are becoming more efficient, the more powerful racks emit significant amounts of heat at the same time. A major problem is the mixing of cooling air with the hot exhaust air from the plants. Even the air-tight sealing of the cable entry in the double floor could reduce costs by a tenth.

  13. Evaluation of high performance evacuated tubular collectors in a residential heating and cooling system: Colorado State University Solar House I. Report for October 1, 1976--September 30, 1977

    Energy Technology Data Exchange (ETDEWEB)

    Duff, W.S.; Conway, T.M.; Loef, G.O.G.; Meredith, D.B.; Pratt, R.B.

    1978-03-01

    CSU Solar House I is configured with a prototype Corning evacuated tubular collector and a new Arkla lithium bromide water chiller designed for solar operation. Data have been collected for this configuration since January 1977. Prior to that time and since mid-1974, Solar House I has operated with a flat-plate collector and a previous Arkla LiBr air conditioner modified to operate in the lower solar temperature ranges. Project objectives were to develop an operating and control system for the new configuration and to compare the performance of the new residential solar heating, cooling, and hot water system with performance of the previous system. Many problems were encountered in the evolution of the operating and control systems due to the different operating characteristics of evacuated tubular collectors, such as their rapid thermal response and the possibility of much higher temperatures as compared to a flat-plate collector.

  14. HVAC&R Equipment Environmental Chambers

    Data.gov (United States)

    Federal Laboratory Consortium — Description:Large "Truck" ChamberThe large "truck" chamber provides controlled air conditions from -7 °C (20 °F) to 65 °C (150 °F).Air-Conditioner and Heat Pump Test...

  15. 利用帕尔贴效应的冷暖型空调床设计及实验分析%Experimental Study of Bed Zoning Air-Conditioner by Using Semiconductor Thermoelectric Effect

    Institute of Scientific and Technical Information of China (English)

    周敬雯; 邓帅; 代彦军; 王如竹

    2012-01-01

    本文基于帕尔贴效应设计了一种冷暖型床体局部空调,简称空调床。空调床由床头制冷装置和床尾供暖装置构成,使床内形成“头凉脚暖”的温度分布。冬季开启供暖模式,可使床内温度达到22°C左右,与房间空调相比,节能率约85%,同时使脚部温度比头部温度高约6°C夏季室温低于30°C时,空调床单独运行,使床内温度降低至28°C左右,节能率约80%。当室温大于30°C时,空调床与房间空调联合运行,与房间空调单独运行相比,节能率为约12%。夏季床内脚部温度比头部温度高1.5°C。%A novel bed zoning air-condition, namely bed AC, was developed based on peltier effect. The Bed AC contains two parts, one is a heating unit on the foot part, and another is a cooling unit on the head part, which can realize "warm feet and cool head". In winter, heat unit operated to maintain bed air temperature around 22°C, and its electrical saving rate was 85%, compared with room AC, and foot air temperature was approximately 6°C higher than that of head. In summer, when room temperature was lower than 30°C, cool unit worked to keep bed air temperature around 28°C, and its energy saving rate was about 80%, and head air temperature was nearly 1.5°C lower than that of foot.. When room temperature was higher than 30°C, bed AC needed to cooperate with room AC, and their total energy saving rate was about 12%, compared with only room AC.

  16. Open-cycle desiccant air conditioning as an alternative to vapor compression cooling in residential applications

    Energy Technology Data Exchange (ETDEWEB)

    Jurinak, J.J.; Beckman, W.A.; Mitchell, J.W.

    1984-08-01

    The performance of open-cycle desiccant air conditioners for residential applications is evaluated. The performance of these systems is compared to that of vapor compression air conditioners on the basis of primary energy use and cost. Systems with improved dehumidifiers can achieve seasonal COP's on the order of 1.1. These systems, when coupled with a solar energy system to supply regeneration energy, are significantly better than conventional air conditioners on a primary energy basis, but are not presently cost-competitive.

  17. Work Breakdown Structure and Plant/Equipment Designation System Numbering Scheme for the High Temperature Gas- Cooled Reactor (HTGR) Component Test Capability (CTC)

    Energy Technology Data Exchange (ETDEWEB)

    Jeffrey D Bryan

    2009-09-01

    This white paper investigates the potential integration of the CTC work breakdown structure numbering scheme with a plant/equipment numbering system (PNS), or alternatively referred to in industry as a reference designation system (RDS). Ideally, the goal of such integration would be a single, common referencing system for the life cycle of the CTC that supports all the various processes (e.g., information, execution, and control) that necessitate plant and equipment numbers be assigned. This white paper focuses on discovering the full scope of Idaho National Laboratory (INL) processes to which this goal might be applied as well as the factors likely to affect decisions about implementation. Later, a procedure for assigning these numbers will be developed using this white paper as a starting point and that reflects the resolved scope and outcome of associated decisions.

  18. Research and Improvement of Scour Sound of Refrigerant in the Refrigeration Process of Wall-mounted Air Conditioner%分体挂壁空调制冷过程制冷剂冲刷声的研究与改善

    Institute of Scientific and Technical Information of China (English)

    张永亮

    2016-01-01

    分体挂壁空调制冷过程出现制冷剂冲刷声,这种低频声穿透性强、辐射面广,严重影响了使用的舒适性。经过测试体验以及现象分析,发现该声音产生的主要原因是蒸发温度与U管温度差过大,导致制冷剂状态的急剧变化产生的噪音。针对该声音产生的机理,制定了有效的改善措施,通过增加低频停留点,提高蒸发温度,减少制冷剂状态的变化,提高了使用舒适性。%In the refrigeration process of wall-mounted air conditioner, the refrigerant scour sound would appear, which has the characteristics of strong penetrability of low-frequency sound and wide radiating surface, it serious affect the comfort of use. Through the test experience and phenomenon analysis, we found the main reasons causing the noise, that is, the large temperature difference between evaporation and U pipe. The rapid change of the state of refrigerant results in the noise. According to the mechanism of the noise generation, the effective improving measure is proposed. Through adding low-frequency arrest points, it raises the evaporating temperature, reduces the changes of refrigerant states, and improves the comfort of use.

  19. 企业创新悖论与两栖组织模式——基于海尔空调产品开发团队案例的研究%Innovation paradox and ambidextrous organization: A case study on development teams of air conditioner in Haier

    Institute of Scientific and Technical Information of China (English)

    王凤彬; 江鸿

    2009-01-01

    新产品开发作为企业自主创新活动的一种重要形式,是知识探索与知识利用有机结合的过程.在对二者悖论关系及其处理方略进行系统文献综述的基础上,将两栖组织的定义从"二元结构"、"二面性结构"伸展到"两栖能力",试图在较低的组织层次上回答如何辩证地解决二者看似矛盾实则可统一的关系.在对海尔空调开发团队的成员构成及异质性知识组合案例分析后,得出的结论是,"两栖"不仅是组织层面的构念,而且可以是团队乃至像"型号经理"这样的个体员工层面的构念.%While knowledge exploration and exploitation represent two distinct activities requiring corresponding organizational arrangements, new product development calls for a dynamic combination of the two. Based on a systematic review of the paradox between knowledge exploration and exploitation and various resolving strategies, this research extends the construct of organizational ambidexterity from dual structure to ambidextrous capabilities, and suggests a dialectical method for reconciling this paradox at lower organizational levels. Based on a case study on the development teams of air conditioner in Haier, we find that ambidexterity is a multi-level construct existing not only at the organization level but also at lower levels such as teams and individuals like model managers.

  20. 40 CFR Appendix B to Subpart B of... - Standard for Recover Equipment

    Science.gov (United States)

    2010-07-01

    ...) AIR PROGRAMS (CONTINUED) PROTECTION OF STRATOSPHERIC OZONE Servicing of Motor Vehicle Air Conditioners... system for compressor lubrication. 6.7.2Refrigerant dissolved in this lubricant must be accounted for...

  1. Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 3, Water heaters, pool heaters, direct heating equipment, and mobile home furnaces

    Energy Technology Data Exchange (ETDEWEB)

    1993-11-01

    This is Volume 3 in a series of documents on energy efficiency of consumer products. This volume discusses energy efficiency of water heaters. Water heaters are defined by NAECA as products that utilize oil, gas, or electricity to heat potable water for use outside the heater upon demand. These are major appliances, which use a large portion (18% on average) of total energy consumed per household (1). They differ from most other appliances in that they are usually installed in obscure locations as part of the plumbing and are ignored until they fail. Residential water heaters are capable of heating water up to 180{degrees}F, although the setpoints are usually set lower.

  2. PERFORMANCE OF A SOLID DESICCANT BASED EVAPORATIVE COOLING SYSTEM IN WARM AND HUMID CLIMATIC ZONE OF INDIA

    Directory of Open Access Journals (Sweden)

    HEMANT PARMAR

    2010-10-01

    Full Text Available Vapour compression based air conditioners are being used for comfort cooling in residences, offices and commercial buildings in many countries throughout the world. Several issues arise seriously challenge the conventional technology which include harmful impact of CFCs and HCFCs on environment, energy and cost problems etc. However use of low energy and eco friendly techniques may be helpful to overcome these problems up to some extent. The evaporative cooling may be considered as one of such eco friendly methods of achieving comfortable conditions in buildings during summer. These systems have great potential to provide thermal comfort in places where ambient air humidity is low. Such systems alone are not efficient for humidclimatic conditions. However such systems can be used if combined with desiccant based dehumidifier. India with its widely different climates has been divided into six climatic zones viz. Hot and Dry, Moderate, Warm and Humid, Composite, Cold and Cloudy and Cold and Sunny. This paper examines the potential of a simple desiccant evaporative cooling cycle in five selected cities in Warm and Humid climatic zone of India. The coefficient of performance (COP has been computed for each location and compared. It has been found that COP for different cities varies in the range of 0.14 to 0.21. Mumbai (coastal city has been identified as the city where desiccant evaporative cooling system can be operated with higher COP compared to that of other cities in the same climatic zone.

  3. 风冷式干除渣系统设备故障分析及处理%Analysis and treatment of equipment faults in air-cooled and dry deslagging system

    Institute of Scientific and Technical Information of China (English)

    何宏; 鲁术全

    2012-01-01

    针对风冷式干除渣设备在应用中出现闸斗堵焦,碎渣机上部蓬焦,清扫链脱轨,碎渣机易损件、斗提机链条和提斗使用周期短等问题,通过对故障原因进行分析,提出了改造方案及措施。改造结果表明:风冷式干除渣系统运行的稳定性、安全性和使用寿命均得到了提高,取得了良好的效果。%Aiming at the problems of the lock hopper coke block, the upper part of slag crusher covered with coke, the cleaning chain disorbition, and the short use cycle such as wearing parts of slag crusher, chain of bucket conveyer and bucket in the application of air-cooled and dry deslagging equipment, analyzes the causation of faults, puts forward improvement schemes and measures. The result shows that after the technical improvement, the stability, safety and service life of the air-cooled and dry deslagging system were promoted, which obtains better effect.

  4. 建设资源节约型医院后勤设备管理探讨%Construction of Resource-saving Logistic Equipment Management in the Hospital

    Institute of Scientific and Technical Information of China (English)

    刘元明; 刘欢

    2013-01-01

      结合我院当前医院电力、空调、电梯等设备管理的内容及特点,探寻有效的管理方式和方法,从根本上提高以上设备管理水平,以提升医疗服务质量和适应医疗保障体系健康发展趋势。%Taking into consideration of the content and characteristics of management of power equipment, air conditioners and elevators, effective management modes and methods are raised in this paper to fundamentally improve the management so as to improve medical service quality and follow the development tendency of the medical security system.

  5. Cryogenic cooling system for HTS cable

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Shigeru [Taiyo Nippon Sanso, Tsukuba (Japan)

    2017-06-15

    Recently, Research and development activity of HTS (High Temperature Superconducting) power application is very progressive worldwide. Especially, HTS cable system and HTSFCL (HTS Fault current limiter) system are proceeding to practical stages. In such system and equipment, cryogenic cooling system, which makes HTS equipment cooled lower than critical temperature, is one of crucial components. In this article, cryogenic cooling system for HTS application, mainly cable, is reviewed. Cryogenic cooling system can be categorized into conduction cooling system and immersion cooling system. In practical HTS power application area, immersion cooling system with sub-cooled liquid nitrogen is preferred. The immersion cooling system is besides grouped into open cycle system and closed cycle system. Turbo-Brayton refrigerator is a key component for closed cycle system. Those two cooling systems are focused in this article. And, each design and component of the cooling system is explained.

  6. 基于局部终端温度调节的中央空调需求响应控制策略%Demand Response Control Strategy for Central Air-conditioner Based on Temperature Adjustment of Partial Terminal Devices

    Institute of Scientific and Technical Information of China (English)

    戚野白; 王丹; 贾宏杰; 黄仁乐; 张逸; 杨占勇

    2015-01-01

    Unlike small amounts of thermostatically controlled appliances (TCAs),the central air-conditioner(CAC) has huge potential ability of demand response by virtue of its large capacity.Focusing on the features of CAC demand response,an integrated model is proposed to describe CAC”s thermodynamic aspects,including the main devices,circulating water system and terminal devices.This paper presents a new CAC control strategy based on temperature adjustment of partial terminal devices which differs from previous methods in concentrating on all the CAC”s terminal devices.The effects of different precision controlling conditions can be reflected by using this model and strategy.Modeling results show that the proposed approach has better performance and efficiency by rational adjustment.%不同于传统单体温控设备,中央空调因其较大的制冷/制热容量而具有更好的需求响应可调潜力。结合中央空调需求响应特点,对其进行了热力学建模,涉及中央空调主机、循环水泵系统、终端组件等动态,形成了多终端中央空调需求响应模型。针对以往中央空调控制策略中对终端整体调节的方法,提出了一种基于局部终端温度调节的控制策略,可实现不同的控制精度。研究结果表明,基于“自下而上”的控制方法,通过合理调节关键的中央空调终端温度设定值,受控群体能够在维持较高用户舒适度的同时,精准响应外界功率信号。

  7. INITIAL COOLING EXPERIMENT (ICE)

    CERN Multimedia

    1979-01-01

    ICE was built in 1977, using the modified bending magnets of the g-2 muon storage ring (see 7405430). Its purpose was to verify the validity of stochastic and electron cooling for the antiproton project. Stochastic cooling proved a resounding success early in 1978 and the antiproton project could go ahead, now entirely based on stochastic cooling. Electron cooling was experimented with in 1979. The 26 kV equipment is housed in the cage to the left of the picture, adjacent to the "e-cooler" located in a straight section of the ring. With some modifications, the cooler was later transplanted into LEAR (Low Energy Antiproton Ring) and then, with further modifications, into the AD (Antiproton Decelerator), where it cools antiprotons to this day (2006). See also: 7711282, 7802099, 7809081.

  8. INITIAL COOLING EXPERIMENT (ICE)

    CERN Multimedia

    1978-01-01

    ICE was built in 1977, in a record time of 9 months, using the modified bending magnets of the g-2 muon storage ring. Its purpose was to verify the validity of stochastic and electron cooling for the antiproton project, to be launched in 1978. Already early in 1978, stochastic cooling proved a resounding success, such that the antiproton (p-pbar)project was entirely based on it. Tests of electron cooling followed later: protons of 46 MeV kinetic energy were cooled with an electron beam of 26 kV and 1.3 A. The cage seen prominently in the foreground houses the HV equipment, adjacent to the "cooler" installed in a straight section of the ring. With some modifications, the cooler was later transplanted into LEAR (Low Energy Antiproton Ring) and then, with further modifications, into the AD (Antiproton Decelerator), where it cools antiprotons to this day (2006). See also: 7711282, 7802099, 7908242.

  9. A preliminary categorization of end-of-life electrical and electronic equipment as secondary metal resources.

    Science.gov (United States)

    Oguchi, Masahiro; Murakami, Shinsuke; Sakanakura, Hirofumi; Kida, Akiko; Kameya, Takashi

    2011-01-01

    End-of-life electrical and electronic equipment (EEE) has recently received attention as a secondary source of metals. This study examined characteristics of end-of-life EEE as secondary metal resources to consider efficient collection and metal recovery systems according to the specific metals and types of EEE. We constructed an analogy between natural resource development and metal recovery from end-of-life EEE and found that metal content and total annual amount of metal contained in each type of end-of-life EEE should be considered in secondary resource development, as well as the collectability of the end-of-life products. We then categorized 21 EEE types into five groups and discussed their potential as secondary metal resources. Refrigerators, washing machines, air conditioners, and CRT TVs were evaluated as the most important sources of common metals, and personal computers, mobile phones, and video games were evaluated as the most important sources of precious metals. Several types of small digital equipment were also identified as important sources of precious metals; however, mid-size information and communication technology (ICT) equipment (e.g., printers and fax machines) and audio/video equipment were shown to be more important as a source of a variety of less common metals. The physical collectability of each type of EEE was roughly characterized by unit size and number of end-of-life products generated annually. Current collection systems in Japan were examined and potentially appropriate collection methods were suggested for equipment types that currently have no specific collection systems in Japan, particularly for video games, notebook computers, and mid-size ICT and audio/video equipment.

  10. 加纳布维水电站技术供水系统选型设计%Type Selection of Equipment in Design of Cooling Water Supply System, Bui Hydropower Project

    Institute of Scientific and Technical Information of China (English)

    刘国峰; 王龙; 陶建民

    2013-01-01

    The unit-based secondary closed circulating water supply means is described in terms of calculation of type selection of main equipment of the secondary closed circulating water supply system and the first cooling water supply/discharge system.Especially, calcu-lation of type selection of the main equipment (such as booster pump, expansion tank) of the secondary closed circulating water supply system is stressed.The unit-based secondary closed circulating water supply system is applied by Bui Hydropower Project.Through the practical operation, the system works smoothly.The unit water supply is specified in comparison with the central water supply system. Namely, one independent water supply system is provided to one turbine-generator unit separately.%文章从二次密闭循环冷却供水系统、一次冷却供排水系统的主要设备选型计算等方面介绍单元二次密闭循环冷却供水方式。其中重点介绍二次密闭循环冷却供水系统关键设备(加压泵、膨胀罐)的选型计算。加纳布维水电站技术供水系统采用单元二次密闭循环冷却供水方式(单元供水是相对于集中供水而言,即每台机设置1套独立的供水系统)。经过实际运行,运行状况良好。

  11. Air cooled absorption chillers for solar cooling applications

    Science.gov (United States)

    Biermann, W. J.; Reimann, R. C.

    1982-03-01

    The chemical composition of a 'best' absorption refrigerant system is identified, and those properties of the system necessary to design hot water operated, air cooled chilling equipment are determined. Air cooled chillers from single family residential sizes into the commercial rooftop size range are designed and operated.

  12. New air conditioner by RMF prevents water in lubricating oils; Neu: Air-Conditioner vom RMF kontra Wasser im Schmieroel

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2001-07-01

    During standstill, water condensation in wind power systems will affect the lubricating properties of the lubricating oil due to oxidation effects. This will result in early failure and irrepairable damage in mechanical components like toothing and rolling bearings. RMF Deutschland, based in Nordorf and Wiesbaden, offer a solution to prevent this. [German] Bei Stillstaenden der Windkraftanlage bildet sich Kondenswasser in nicht unerheblichen Umfang. Bekannterweise beeinflussen schon geringe Wasseranteile die Schmierfaehigkeit und Eigenschaften des Schmieroels (Oxidation im Oel). Ergebnisse sind vorzeitige Ausfaelle und irreparable Schaeden an den mechanischen Bauteilen wie Verzahnung und Waelzlager. RMF Deutschland aus Nordorf und Wiesbaden bietet die Loesung, hier vorbeugend einzugreifen. (orig.)

  13. Electron cooling

    Science.gov (United States)

    Meshkov, I.; Sidorin, A.

    2004-10-01

    The brief review of the most significant and interesting achievements in electron cooling method, which took place during last two years, is presented. The description of the electron cooling facilities-storage rings and traps being in operation or under development-is given. The applications of the electron cooling method are considered. The following modern fields of the method development are discussed: crystalline beam formation, expansion into middle and high energy electron cooling (the Fermilab Recycler Electron Cooler, the BNL cooler-recuperator, cooling with circulating electron beam, the GSI project), electron cooling in traps, antihydrogen generation, electron cooling of positrons (the LEPTA project).

  14. Stochastic Cooling

    Energy Technology Data Exchange (ETDEWEB)

    Blaskiewicz, M.

    2011-01-01

    Stochastic Cooling was invented by Simon van der Meer and was demonstrated at the CERN ISR and ICE (Initial Cooling Experiment). Operational systems were developed at Fermilab and CERN. A complete theory of cooling of unbunched beams was developed, and was applied at CERN and Fermilab. Several new and existing rings employ coasting beam cooling. Bunched beam cooling was demonstrated in ICE and has been observed in several rings designed for coasting beam cooling. High energy bunched beams have proven more difficult. Signal suppression was achieved in the Tevatron, though operational cooling was not pursued at Fermilab. Longitudinal cooling was achieved in the RHIC collider. More recently a vertical cooling system in RHIC cooled both transverse dimensions via betatron coupling.

  15. High Energy Efficiency Air Conditioning

    Energy Technology Data Exchange (ETDEWEB)

    Edward McCullough; Patrick Dhooge; Jonathan Nimitz

    2003-12-31

    This project determined the performance of a new high efficiency refrigerant, Ikon B, in a residential air conditioner designed to use R-22. The refrigerant R-22, used in residential and small commercial air conditioners, is being phased out of production in developed countries beginning this year because of concerns regarding its ozone depletion potential. Although a replacement refrigerant, R-410A, is available, it operates at much higher pressure than R-22 and requires new equipment. R-22 air conditioners will continue to be in use for many years to come. Air conditioning is a large part of expensive summer peak power use in many parts of the U.S. Previous testing and computer simulations of Ikon B indicated that it would have 20 - 25% higher coefficient of performance (COP, the amount of cooling obtained per energy used) than R-22 in an air-cooled air conditioner. In this project, a typical new R-22 residential air conditioner was obtained, installed in a large environmental chamber, instrumented, and run both with its original charge of R-22 and then with Ikon B. In the environmental chamber, controlled temperature and humidity could be maintained to obtain repeatable and comparable energy use results. Tests with Ikon B included runs with and without a power controller, and an extended run for several months with subsequent analyses to check compatibility of Ikon B with the air conditioner materials and lubricant. Baseline energy use of the air conditioner with its original R-22 charge was measured at 90 deg F and 100 deg F. After changeover to Ikon B and a larger expansion orifice, energy use was measured at 90 deg F and 100 deg F. Ikon B proved to have about 19% higher COP at 90 deg F and about 26% higher COP at 100 deg F versus R-22. Ikon B had about 20% lower cooling capacity at 90 deg F and about 17% lower cooling capacity at 100 deg F versus R-22 in this system. All results over multiple runs were within 1% relative standard deviation (RSD). All of these

  16. China Cools with Tighter RAC Standards

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Jiang; Rosenquist, Gregory

    2006-06-01

    After boiling summer brought brown-out to most part of the country in 2004, China announced a new set of minimum energy efficiency standards for room air conditioners in September 2004, with the first tier going into effect on March 1, 2005 and the reach standard taking effect on January 1, 2009. This represents a milestone in China's standard setting process since the reach standard levels are significantly more stringent than previous standards for other appliances. This paper first analyzes cost-effectiveness of China's new standards for room air conditioners, and then attempts to evaluate the impact of the new standards on energy savings, electric generation capacity, and CO2 emissions reductions.

  17. Characterizing of Cooling Equipment for Closed Greenhouses

    NARCIS (Netherlands)

    Zwart, de H.F.; Kempkes, F.L.K.

    2008-01-01

    In order to develop new eco-sustainable technologies to set up biodegradable films for agricultural activities, spray mulching coating have been planned, prepared and tested on experimental fields. The suitable polymers used to this purpose were Arabic Gums and Agarose. Cellulose fibres were added

  18. Development of Separate Sensible and Latent Cooling System Using Electrochemical Compressor

    Energy Technology Data Exchange (ETDEWEB)

    Abdelaziz, Omar [ORNL; Qu, Ming [Purdue University; Sun, Xiao-Guang [ORNL; Bahar, Bamdad [Xergy Inc.; Parmelee, William [Xergy Inc.; Fackler, Scott [Xergy Inc.; Sherrer, Richard [Xergy Inc.; Zerby, Jacob [Xergy Inc.; Chouhan, Ashish [University of Delaware; Prasad, Ajay [University of Delaware

    2017-01-01

    Separate sensible and latent cooling systems offer superior energy efficiency performance compared to conventional vapor compression air conditioning systems. In this paper we describe an innovative non-vapor compression system that uses electrochemical compressor (ECC) to pump hydrogen between 2-metal hydride reservoirs to provide the sensible cooling effect. The heat rejected during this process is used to regenerate the ionic liquid (IL) used for desiccant dehumidification. The overall system design is illustrated. The Xergy version 4C electrochemical compressor, while not designed as a high pressure system, develops in excess of 2 MPa (300 psia) and pressure ratios > 30. The projected base efficiency improvement of the electrochemical compressor is expected to be ~ 20% with higher efficiency when in low capacity mode due to being throttleable to lower capacity with improved efficiency. The IL was tailored to maximize the absorption/desorption rate of water vapor at moderate regeneration temperature. This IL, namely, [EMIm].OAc, is a hydrophilic IL with a working concentration range of 28.98% when operating between 25 75 C. The ECC metal hydride system is expected to show superior performance to typical vapor compression systems. As such, the combined efficiency gains from the use of ECC and separate and sensible cooling would offer significant potential savings to existing vapor compression cooling technology. A high efficiency Window Air Conditioner system is described based on this novel configuration. The system s schematic is provided. Models compared well with actual operating data obtained by running the prototype system. Finally, a model of an LiCl desiccant system in conjunction with the ECC-based metal hydride heat exchangers is provided.

  19. Air conditioning and blowers. Special issue; Airconditioning en ventilatoren. Themanummer

    Energy Technology Data Exchange (ETDEWEB)

    Nekeman, H.E. [Multi Import, Rotterdam (Netherlands); Hol, M. [Aircool Klimaattechniek, Ridderkerk (Netherlands); Bassa, E. [ed.

    1997-06-01

    In four articles several aspects of air conditioners and blowers are discussed: the application of the newly developed electronically commutated direct current engine in high-efficiency boilers, air conditioners and cooling systems, the future for flexible synthetic cooling pipes, a description of a Mitsubishi-developed air conditioner: the Inverter Driven Multi-indoor unit, also known as the KX-system, and the importance of the private sector (houses, small businesses, cars) for the use of air conditioning installations. 8 figs.

  20. Motor-driven compressor-condenser group for cooling cycles

    Energy Technology Data Exchange (ETDEWEB)

    Giuffrida, G.G.

    1984-07-17

    A motor-driven compressor condenser group for equipment actuating cooling-cycles, such as for example cooling apparatuses and heat pumps, enclosed in a single container. The cooling fluid of the heat-exchanger connected to the condenser passing to and from the container is to be used in domestic cooling systems to heat water.

  1. Progress of the Water Cooling System for CYCIAE-100

    Institute of Scientific and Technical Information of China (English)

    LI; Zhen-guo; WU; Long-cheng; LIU; Geng-guo

    2013-01-01

    The water cooling system for CYCIAE-100 has achieved a significant progress in 2013,its progress can be summarized as follows:1)The deionized water production equipment and the main circulating water cooling unit are installed and tested.2)The circulating water cooling unit for high power target and circulating water cooling unit for vacuum helium compressor are installed and tested.

  2. Danish Cool

    DEFF Research Database (Denmark)

    Toft, Anne Elisabeth

    2016-01-01

    Danish Cool. Keld Helmer-Petersen, Photography and the Photobook Handout exhibition text in English and Chinese by Anne Elisabeth Toft, Curator The exhibition Danish Cool. Keld Helmer-Petersen, Photography and the Photobook presents the ground-breaking work of late Danish photographer Keld Helmer...

  3. HG-45b宽温区环控装置研发%Research and Development of HG-45b Environmental Control Equipment for Wide Temperature Range

    Institute of Scientific and Technical Information of China (English)

    陶安发; 王铁军; 陈志文; 江斌; 张周品

    2013-01-01

    Effects of flow and heat transfer characteristics of medium and high temperature mixed-refrigerant on system performance were analyzed combing with the application experience of HLD-45b according to the requirement of man-machine environment control of wide-temperature range of transporting vehicle. It was concluded that evaporator structure optimization and enhancement of indoor side heat transfer capacity were the key points to improve the performance of air conditioner. HG-45b air conditioner was developed which used HLD-45b outdoor unit and wall-mounted style of indoor unit, to meet the practical applications requirements. Heat transfer area and air volume were both increased while changing the evaporation duct structure and the thermal expansion valve was also optimized. The test data showed that cooling capacity and EER of HG-45b are 10% and 14.5%more than that of HLD-45b respectively while its input power is 5%less;the system performance is stable while the exhaust temperature and pressure of compressor are in the safe range, and the optimized goal is achieved.%  针对载运装备宽温区人机环控的需要,在HLD-45b环控装置应用实践的基础上,分析了中高温混合工质流动和传热特性对系统性能的影响,认为优化蒸发器结构、强化室内侧换热能力可进一步提升产品性能.根据应用需求研发了HG-45b宽温区环控装置,基于HLD-45b的室外机配套设计了壁挂式的室内机,改进蒸发盘管结构、增大换热面积和蒸发风量,并优化热力膨胀阀的匹配.新款HG-45b与HLD-45b的检测对比数据表明,制冷量提高约10%,压缩机功率降低约5%,能效比提高约14.5%,系统性能稳定,压缩机排气温度、排气压力均在安全范围内,达到了系统优化的目标.

  4. Monitoring peak power and cooling energy savings of shade trees and white surfaces in the Sacramento Municipal Utility District (SMUD) service area: Project design and preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Akbari, H.; Bretz, S.; Hanford, J.; Rosenfeld, A.; Sailor, D.; Taha, H. [Lawrence Berkeley Lab., CA (United States); Bos, W. [Sacramento Municipal Utility District, CA (United States)

    1992-12-01

    Urban areas in warm climates create summer heat islands of daily average intensity of 3--5{degrees}C, adding to discomfort and increasing air-conditioning loads. Two important factors contributing to urban heat islands are reductions in albedo (lower overall city reflectance) and loss of vegetation (less evapotranspiration). Reducing summer heat islands by planting vegetation (shade trees) and increasing surface albedos, saves cooling energy, allows down-sizing of air conditioners, lowers air-conditioning peak demand, and reduces the emission of CO{sub 2} and other pollutants from electric power plants. The focus of this multi-year project, jointly sponsored by SMUD and the California Institute for Energy Efficiency (CIEE), was to measure the direct cooling effects of trees and white surfaces (mainly roofs) in a few buildings in Sacramento. The first-year project was to design the experiment and obtain base case data. We also obtained limited post retrofit data for some sites. This report provides an overview of the project activities during the first year at six sites. The measurement period for some of the sites was limited to September and October, which are transitional cooling months in Sacramento and hence the interpretation of results only apply to this period. In one house, recoating the dark roof with a high-albedo coating rendered air conditioning unnecessary for the month of September (possible savings of up to 10 kWh per day and 2 kW of non-coincidental peak power). Savings of 50% relative to an identical base case bungalow were achieved when a school bungalow`s roof and southeast wall were coated with a high-albedo coating during the same period. Our measured data for the vegetation sites do not indicate conclusive results because shade trees were small and the cooling period was almost over. We need to collect more data over a longer cooling season in order to demonstrate savings conclusively.

  5. Production and exploitation of thermoelectric air conditioning systems for vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Dudnik, Vladimir [Conditioner Ltd, Gagarin (Russian Federation); Skipidarov, Sergey [SCTB NORD, Moskau (Russian Federation); Rapp, Axel [Quick-Ohm Kupper und Co. GmbH, Wuppertal-Cronenberg (Germany)

    2011-07-01

    In the paper more than 10-year experience of thermoelectric devices batch manufacturing is described for the field of their obvious advantages. This field of application includes thermoelectric air conditioning systems which have shown their competitive advantage when used in vehicles of elevated vibration where compressor equipment application is difficult because of leakage of refrigerant. Energy characteristics of air conditioners for tractors, excavators, tanks, locomotive driver's cabins and cranes are described. Thermoelectric (TE) air conditioners mechanical test data as well as operation experience in vehicles are presented. It is shown that consumption of tellurium, which is a strategic component for thermoelectric materials manufacturing, may be lowered to 40 grams per 1 kW of cooling. (orig.)

  6. Methods and apparatus for cooling electronics

    Science.gov (United States)

    Hall, Shawn Anthony; Kopcsay, Gerard Vincent

    2014-12-02

    Methods and apparatus are provided for choosing an energy-efficient coolant temperature for electronics by considering the temperature dependence of the electronics' power dissipation. This dependence is explicitly considered in selecting the coolant temperature T.sub.0 that is sent to the equipment. To minimize power consumption P.sub.Total for the entire system, where P.sub.Total=P.sub.0+P.sub.Cool is the sum of the electronic equipment's power consumption P.sub.0 plus the cooling equipment's power consumption P.sub.Cool, P.sub.Total is obtained experimentally, by measuring P.sub.0 and P.sub.Cool, as a function of three parameters: coolant temperature T.sub.0; weather-related temperature T.sub.3 that affects the performance of free-cooling equipment; and computational state C of the electronic equipment, which affects the temperature dependence of its power consumption. This experiment provides, for each possible combination of T.sub.3 and C, the value T.sub.0* of T.sub.0 that minimizes P.sub.Total. During operation, for any combination of T.sub.3 and C that occurs, the corresponding optimal coolant temperature T.sub.0* is selected, and the cooling equipment is commanded to produce it.

  7. Use of local convective and radiant cooling at warm environment

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor; Krejcirikova, Barbora; Kaczmarczyk, Jan

    2012-01-01

    with one panel equipped with small fans. A reference condition without cooling was tested as well. The response of the subjects to the exposed conditions was collected by computerized questionnaires. The cooling devices significantly (p.... The acceptability of the thermal environment was similar for all cooling devices. The acceptability of air movement and PAQ increased when the local cooling methods were used. The best results were achieved with personalized ventilation and cooling fan. The minimal improvement in PAQ was reported when the radiant...

  8. Cooling Floor AC Systems

    Science.gov (United States)

    Jun, Lu; Hao, Ding; Hong, Zhang; Ce, Gao Dian

    The present HVAC equipments for the residential buildings in the Hot-summer-and-Cold-winter climate region are still at a high energy consuming level. So that the high efficiency HVAC system is an urgently need for achieving the preset government energy saving goal. With its advantage of highly sanitary, highly comfortable and uniform of temperature field, the hot-water resource floor radiation heating system has been widely accepted. This paper has put forward a new way in air-conditioning, which combines the fresh-air supply unit and such floor radiation system for the dehumidification and cooling in summer or heating in winter. By analyze its advantages and limitations, we found that this so called Cooling/ Heating Floor AC System can improve the IAQ of residential building while keep high efficiency quality. We also recommend a methodology for the HVAC system designing, which will ensure the reduction of energy cost of users.

  9. Ventilative Cooling

    DEFF Research Database (Denmark)

    Heiselberg, Per Kvols; Kolokotroni, Maria

    This report, by venticool, summarises the outcome of the work of the initial working phase of IEA ECB Annex 62 Ventilative Cooling and is based on the findings in the participating countries. It presents a summary of the first official Annex 62 report that describes the state-of-the-art of ventil......This report, by venticool, summarises the outcome of the work of the initial working phase of IEA ECB Annex 62 Ventilative Cooling and is based on the findings in the participating countries. It presents a summary of the first official Annex 62 report that describes the state...

  10. Cool snacks

    DEFF Research Database (Denmark)

    Grunert, Klaus G; Brock, Steen; Brunsø, Karen

    2016-01-01

    such a product requires an interdisciplinary effort where researchers with backgrounds in psychology, anthropology, media science, philosophy, sensory science and food science join forces. We present the COOL SNACKS project, where such a blend of competences was used first to obtain thorough insight into young...

  11. 78 FR 40403 - Energy Conservation Program for Consumer Products and Certain Commercial and Industrial Equipment...

    Science.gov (United States)

    2013-07-05

    ... ACs satisfy the requirements of 42 U.S.C. 6295(l)(1). After the publication of the NOPR, DOE affords... ``Department'') has determined tentatively that portable air conditioners (ACs) qualify as a covered product... determined that portable ACs meet the criteria for covered products because classifying products of such type...

  12. Mechanical (turbines and auxiliary equipment)

    CERN Document Server

    Sherry, A; Cruddace, AE

    2013-01-01

    Modern Power Station Practice, Volume 3: Mechanical (Turbines and Auxiliary Equipment) focuses on the development of turbines and auxiliary equipment used in power stations in Great Britain. Topics covered include thermodynamics and steam turbine theory; turbine auxiliary systems such as lubrication systems, feed water heating systems, and the condenser and cooling water plants. Miscellaneous station services, and pipework in power plants are also described. This book is comprised of five chapters and begins with an overview of thermodynamics and steam turbine theory, paying particular attenti

  13. Stochastic cooling

    Energy Technology Data Exchange (ETDEWEB)

    Bisognano, J.; Leemann, C.

    1982-03-01

    Stochastic cooling is the damping of betatron oscillations and momentum spread of a particle beam by a feedback system. In its simplest form, a pickup electrode detects the transverse positions or momenta of particles in a storage ring, and the signal produced is amplified and applied downstream to a kicker. The time delay of the cable and electronics is designed to match the transit time of particles along the arc of the storage ring between the pickup and kicker so that an individual particle receives the amplified version of the signal it produced at the pick-up. If there were only a single particle in the ring, it is obvious that betatron oscillations and momentum offset could be damped. However, in addition to its own signal, a particle receives signals from other beam particles. In the limit of an infinite number of particles, no damping could be achieved; we have Liouville's theorem with constant density of the phase space fluid. For a finite, albeit large number of particles, there remains a residue of the single particle damping which is of practical use in accumulating low phase space density beams of particles such as antiprotons. It was the realization of this fact that led to the invention of stochastic cooling by S. van der Meer in 1968. Since its conception, stochastic cooling has been the subject of much theoretical and experimental work. The earliest experiments were performed at the ISR in 1974, with the subsequent ICE studies firmly establishing the stochastic cooling technique. This work directly led to the design and construction of the Antiproton Accumulator at CERN and the beginnings of p anti p colliding beam physics at the SPS. Experiments in stochastic cooling have been performed at Fermilab in collaboration with LBL, and a design is currently under development for a anti p accumulator for the Tevatron.

  14. Waste electrical and electronic equipment (WEEE) estimation: A case study of Ahvaz City, Iran.

    Science.gov (United States)

    Alavi, Nadali; Shirmardi, Mohammad; Babaei, Aliakbar; Takdastan, Afshin; Bagheri, Nastaran

    2015-03-01

    The development of new technologies and the increasing consumption of electronic and electrical equipment have led to increased generation of e-waste in the municipal waste streams. This waste due to the presence of hazardous substances in its composition needs specific attention and management. The present study was carried out in Ahvaz metropolis using a survey method in 2011. For estimating the amount of waste electrical and electronic equipment (WEEE) generated, the "use and consumption" method was used. In order to determine the amounts of the electrical and electronic equipment that were used and their lifetime, and for investigating the current status of e-waste management in Ahvaz, an appropriate questionnaire was devised. In 2011, the total number of discarded electronic items was 2,157,742 units. According to the average weight of the equipment, the total generation of e-waste was 9952.25 metric tons per year and was 9.95 kg per capita per year. The highest e-waste generated was related to air conditioners, with 3125.36 metric tons per year, followed by the wastes from refrigerators and freezers, washing machines, and televisions. The wastes from desktop computers and laptops were 418 and 63 metric tons/year, respectively, and the corresponding values per capita were 0.42 and 0.063 kg, respectively. These results also showed that 10 tons fixed phones, 25 tons mobile phones, and by considering an average lifetime of 3 years for each lamp about 320 tons lamps were generated as e-waste in Ahvaz in the year 2011. Based on this study, currently there is not an integrated system for proper management of WEEE in Ahvaz, and this waste stream is collected and disposed of with other municipal waste. Some measures, including a specific collection system, recycling of valuable substances, and proper treatment and disposal, should be done about such waste. Ahvaz is one of the most important economic centers of Iran, and to the best of our knowledge, no study has been

  15. Modeling of In-vehicle Magnetic refrigeration

    DEFF Research Database (Denmark)

    Olsen, Ulrik Lund; Bahl, Christian; Engelbrecht, Kurt

    2012-01-01

    A high-performance magnetic refrigeration device is considered as a potential technology for in-vehicle air conditioners in electric vehicles. The high power consumption of a conventional air conditioner in an electric vehicle has considerable impacts on cruising distance. For this purpose...... the demands on cooling power density, temperature difference between hot and cold side, transient properties and COP, will be high....

  16. The future of CO2 cooling in particle physics detectors

    NARCIS (Netherlands)

    B. Verlaat; A.P. Colijn; H. Postema

    2011-01-01

    Evaporative CO2 cooling has attracted a lot of interest as cooling fluid for particle physics detectors. Two detectors (the AMS on the International Space Station and the LHCb at the Large Hadron Collider at CERN) have been equipped with CO2 cooling; many more particle detectors are considering it f

  17. A very cool cooling system

    CERN Multimedia

    Antonella Del Rosso

    2015-01-01

    The NA62 Gigatracker is a jewel of technology: its sensor, which delivers the time of the crossing particles with a precision of less than 200 picoseconds (better than similar LHC detectors), has a cooling system that might become the precursor to a completely new detector technique.   The 115 metre long vacuum tank of the NA62 experiment. The NA62 Gigatracker (GTK) is composed of a set of three innovative silicon pixel detectors, whose job is to measure the arrival time and the position of the incoming beam particles. Installed in the heart of the NA62 detector, the silicon sensors are cooled down (to about -20 degrees Celsius) by a microfluidic silicon device. “The cooling system is needed to remove the heat produced by the readout chips the silicon sensor is bonded to,” explains Alessandro Mapelli, microsystems engineer working in the Physics department. “For the NA62 Gigatracker we have designed a cooling plate on top of which both the silicon sensor and the...

  18. Simulation of Desiccant Cooling

    Directory of Open Access Journals (Sweden)

    Kamaruddin A.

    2017-06-01

    Full Text Available Desiccant cooling system has been an attractive topic for study lately, due to its environmentally friendly nature. It also consume less electricity and capable to be operated without refrigerant. A simulation study was conducted using 1.5 m long ducting equipped with one desiccant wheel, one sensible heat exchanger wheel, one evaporative cooling chamber and two blowers and one electric heater. The simulation study used 8.16 m/s primary air, the drying coefficient from desiccant wheel, k1=2.1 (1/s, mass transfer coefficient in evaporative cooling, k2=1.2 kg vapor/s, heat transfer coefficient in desiccant wheel, h1=4.5 W/m2 oC, and heat transfer coefficient in sensible heat exchanger wheel h2= 4.5 W/m2 oC. The simulation results show that the final temperature before entering into the air conditioning room was 25 oC and RH of 65 %, were in accordance with the Indonesian comfort index.

  19. Behavior of urban residents toward the discarding of waste electrical and electronic equipment: a case study in Baoding, China.

    Science.gov (United States)

    Li, Jinhui; Liu, Lili; Ren, Junshu; Duan, Huabo; Zheng, Lixia

    2012-11-01

    The volume of waste electrical and electronic equipment (WEEE) is growing rapidly worldwide, making its management difficult; therefore, this should be improved as a matter of urgency. WEEE includes both essential household appliances [including televisions, refrigerators, and washing machines; but not air conditioners, where the consumption mode is more like information, communication and technology (ICT)] ICT equipment (also called high-tech household appliances). In the present study, Baoding, a medium-sized, prefecture-level city in north central China with a population of 11 million, including 1.1 million urban residents, was selected as a representative city for an investigation of recycling behaviors. A valid sample size of 346 households in Baoding was investigated, and categorized into various income and educational levels. The results showed that the major reason for discarding WEEE was malfunction of the appliance, accounting for 52% of disposals. Surveyed households with either high income or good education were more likely to consume high-tech household appliances, attracted by advanced technology, versatile functions or flexibility of use. Personal computer ownership rates were highest in households with a high income and good education-1.2 and 0.9 per home respectively. WEEE was most often sold to peddlers or hawkers from where the WEEE flowed into the second-hand market to be refurbished or repaired, and then re-sold. However, 56.3% of residents in the college community were in support of charging consumers for disposal and 61.7% were in support of including a disposal surcharge in the purchase price of new products-a percentage approximately three times that for high-income residents. Thus, high educational level appears to be currently the most important factor in raising the potential of a household's willingness to pay for WEEE treatment cost. The findings of this study can be used to develop sound recycling systems for WEEE in mainland China.

  20. Solar heating and cooling.

    Science.gov (United States)

    Duffie, J A; Beckman, W A

    1976-01-16

    We have adequate theory and engineering capability to design, install, and use equipment for solar space and water heating. Energy can be delivered at costs that are competitive now with such high-cost energy sources as much fuel-generated, electrical resistance heating. The technology of heating is being improved through collector developments, improved materials, and studies of new ways to carry out the heating processes. Solar cooling is still in the experimental stage. Relatively few experiments have yielded information on solar operation of absorption coolers, on use of night sky radiation in locations with clear skies, on the combination of a solar-operated Rankine engine and a compression cooler, and on open cycle, humidification-dehumidification systems. Many more possibilities for exploration exist. Solar cooling may benefit from collector developments that permit energy delivery at higher temperatures and thus solar operation of additional kinds of cycles. Improved solar cooling capability can open up new applications of solar energy, particularly for larger buildings, and can result in markets for retrofitting existing buildings. Solar energy for buildings can, in the next decade, make a significant contribution to the national energy economy and to the pocketbooks of many individual users. very large-aggregate enterprises in manufacture, sale, and installation of solar energy equipment can result, which can involve a spectrum of large and small businesses. In our view, the technology is here or will soon be at hand; thus the basic decisions as to whether the United States uses this resource will be political in nature.

  1. Cooling technique

    Energy Technology Data Exchange (ETDEWEB)

    Salamon, Todd R; Vyas, Brijesh; Kota, Krishna; Simon, Elina

    2017-01-31

    An apparatus and a method are provided. Use is made of a wick structure configured to receive a liquid and generate vapor in when such wick structure is heated by heat transferred from heat sources to be cooled off. A vapor channel is provided configured to receive the vapor generated and direct said vapor away from the wick structure. In some embodiments, heat conductors are used to transfer the heat from the heat sources to the liquid in the wick structure.

  2. ATLAS - Liquid Cooling Systems

    CERN Multimedia

    Bonneau, P.

    1998-01-01

    Photo 1 - Cooling Unit - Side View Photo 2 - Cooling Unit - Detail Manifolds Photo 3 - Cooling Unit - Rear View Photo 4 - Cooling Unit - Detail Pump, Heater and Exchanger Photo 5 - Cooling Unit - Detail Pump and Fridge Photo 6 - Cooling Unit - Front View

  3. Drilling equipment

    Energy Technology Data Exchange (ETDEWEB)

    Voyevodin, Yu.M.; Kholosha, Ye.G.; Leshchenko, A.G.; Timchenko, A.I.

    1979-01-10

    The invention refers to units designed for extracting minerals by mechanical action on the face by a cutting tool. There is a known drills which includes a pulse device which contains a combustion chamber, cylinder, piston-percussion tool and cutting tool. The combustion chamber and the sub-piston cavity of the cylinder are connected by a channel in which there is a distributor. Its shortcoming is the fact that the pulse device does not guarantee the necessary motion of the actuating mechanism for its velocity and frequency of the shocks on the cutting tool. This reduces the efficiency of the operation and limits the area of application. The purpose of the proposed invention is to improve productivity of the device. This is achieved because the head of the drill is equipped with a 2-piston pulse device which contains 2-combustion chambers, 2 working cylinders, 2 piston percussion instruments, a rod with gas-conducting and connecting channels for interconnection of the sub-piston cavities and combustion chambers of both cylinders. The spent gases of one cylinder are used for closing the combustion chamber of the second cylinder.

  4. Cooling Effect of Evapotranspiration (ET) and ET Measurement by Thermal Remote Sensing in Urban

    Science.gov (United States)

    Qiu, G. Y.; Yang, B.; Li, X.; Guo, Q.; Tan, S.

    2015-12-01

    Affected by global warming and rapid urbanization, urban thermal environment and livability are getting worse over the world. Global terrestrial evapotranspiration (ET) can annually consume 1.483 × 1023 joules of solar energy, which is about 300 times of the annual human energy use on the earth (4.935×1020 joules). This huge amount of energy use by ET indicates that there is great potential to cool the urban by regulating ET. However, accurately measurement of urban ET is quiet difficult because of the great spatial heterogeneity in urban. This study focuses on to quantify the cooling effects ET by mobile traverse method and improve a methodology to measure the urban ET by thermal remote sensing. The verifying experiment was carried out in Shenzhen, a sub-tropical mega city in China. Results showed that ET of vegetation could obviously reduce the urban temperature in hot season. Daily transpiration rate of a small-sized Ficus tree (Ficus microcarpa, 5 m in height and 20 cm of trunk diameter, measured by sap-flow method) was 36-55 kg and its cooling effect was equivalent to a 1.6-2.4 kWh air conditioner working for 24 hours. A 10% increase in the vegetated area could decrease urban temperature by 0.60°C at hot night. Moreover, it was found that a region with a vegetated area ratio over 55% had obvious effect on temperature decreasing. In addition, a methodology by using "thermal remote sensing + three-temperature model" was improved to measure the urban ET. Results showed that the urban ET could be reasonably measured by the proposed method. The daily ET of an urban lawn was 0.01-2.86 mm and monthly ET was 21-60 mm. This result agreed well with the verification study (Bowen ratio method, r=0.953). These results are very useful for urban planning, urban lower impact development, and improving of urban thermal environment.

  5. The development of advanced cooling methods for high-power electronics

    Science.gov (United States)

    Bland, T. J.; Ciaccio, M. P.; Downing, R. S.; Smith, W. G.

    1990-10-01

    Consideration is given to various technologies developed to meet the difficult cooling requirements of high-density power electronics equipment for the aerospace industry. Topics discussed include liquid impingement cooling, compact high-density cooler, integrally cooled semiconductor, high heat flux cold plane, immersion cooling, modular reflux cooler, and forced-flow two-phase cooling systems. It is concluded that the new technologies are capable of providing the temperature control necessary to maintain desired electronic reliabilities using high-conductance cooling approaches.

  6. Aquatic Equipment Information.

    Science.gov (United States)

    Sova, Ruth

    Equipment usually used in water exercise programs is designed for variety, intensity, and program necessity. This guide discusses aquatic equipment under the following headings: (1) equipment design; (2) equipment principles; (3) precautions and contraindications; (4) population contraindications; and (5) choosing equipment. Equipment is used…

  7. Optimizing design for equipment cooling pipe of segment of slab caster%板坯连铸机扇形段机冷配管的改进设计

    Institute of Scientific and Technical Information of China (English)

    周士凯; 田进; 王蓉; 李新强; 薛松

    2013-01-01

    The original cooling pipe of segment for R steel plant slab CCM is welded with stainless steel rectangular tubes.Its disadvantages embodied in the complex structure,the large cost of manufacturing and repair,low service life,and difficulty to repair the water leakage.Based on the improved design,intergranular corrosion caused by Heat treatment is avoided,iron scrap is avoided into the tubes,and its service life is prolonged,its structure is more simple and more convenient to repair.%R钢厂板坯连铸机扇形段原机冷配管由不锈钢矩形管焊接而成,结构复杂,维修制造成本大,使用寿命低,漏水后修复难.通过对其结构改进设计,避免了不锈钢管路随框架进行热处理而引起的晶间腐蚀,避免了铁屑进入矩形管内,延长了其使用寿命,结构简化,维修更方便.

  8. Cool visitors

    CERN Multimedia

    2006-01-01

    Pictured, from left to right: Tim Izo (saxophone, flute, guitar), Bobby Grant (tour manager), George Pajon (guitar). What do the LHC and a world-famous hip-hop group have in common? They are cool! On Saturday, 1st July, before their appearance at the Montreux Jazz Festival, three members of the 'Black Eyed Peas' came on a surprise visit to CERN, inspired by Dan Brown's Angels and Demons. At short notice, Connie Potter (Head of the ATLAS secretariat) organized a guided tour of ATLAS and the AD 'antimatter factory'. Still curious, lead vocalist Will.I.Am met CERN physicist Rolf Landua after the concert to ask many more questions on particles, CERN, and the origin of the Universe.

  9. R744 air conditioner with stop/start air conditioning, parking air conditioning and heat pump function in the ''COMET'' test car; R744-Klimaanlage mit Stopp/Start- und Standklimatisierung sowie Waermepumpenfunktion im Versuchstraeger ''COMET''

    Energy Technology Data Exchange (ETDEWEB)

    Brandes, H.; Horstmann, P.; Kneifel, M.; Hohl, R. [Robert Bosch GmbH, Schwieberdingen (Germany)

    2006-07-01

    Within a several years development project Robert Bosch GmbH has setup a test vehicle to investigate an integral energy management concept (COMET - Control of Mechanical, Electrical and Thermal Power). Key feature of the COMET vehicle concept is the hybrid drive train comprising the standard combustion engine and two electrical motors - each with 8 kW - being integrated in the power splitting Dual-E gearbox. Directly via the gearbox the compressor of the CO{sub 2} A/C system is driven so that an electrically parking and start-stop air condition and heating function using a CO{sub 2} heat pump can be realized. System setup, Cool down and heating up tests are shown and discussed. (orig.)

  10. Personal cooling apparatus and method

    Energy Technology Data Exchange (ETDEWEB)

    Siman-Tov, Moshe (Knoxville, TN); Crabtree, Jerry Allen (Knoxville, TN)

    2001-01-01

    A portable lightweight cooling apparatus for cooling a human body is disclosed, having a channeled sheet which absorbs sweat and/or evaporative liquid, a layer of highly conductive fibers adjacent the channeled sheet; and, an air-moving device for moving air through the channeled sheet, wherein the layer of fibers redistributes heat uniformly across the object being cooled, while the air moving within the channeled sheet evaporates sweat and/or other evaporative liquid, absorbs evaporated moisture and the uniformly distributed heat generated by the human body, and discharges them into the environment. Also disclosed is a method for removing heat generated by the human body, comprising the steps of providing a garment to be placed in thermal communication with the body; placing a layer of highly conductive fibers within the garment adjacent the body for uniformly distributing the heat generated by the body; attaching an air-moving device in communication with the garment for forcing air into the garment; removably positioning an exchangeable heat sink in communication with the air-moving device for cooling the air prior to the air entering the garment; and, equipping the garment with a channeled sheet in communication with the air-moving device so that air can be directed into the channeled sheet and adjacent the layer of fibers to expell heat and moisture from the body by the air being directed out of the channeled sheet and into the environment. The cooling system may be configured to operate in both sealed and unsealed garments.

  11. Influencia del alineamiento en frío. Análisis y métodos de corrección // Influence in rotating equipment of alignment in cool stage. Analysis and corrections methods.

    Directory of Open Access Journals (Sweden)

    Y. M. Abreu-Rivero

    2009-05-01

    Full Text Available En trabajos realizados por el autor sobre la indisponibilidad de equipos auxiliares de turbina, en unacentral Termoeléctrica de 125 Mw, de procedencia checa, se detectó que uno de los equipos quemayor incidencia tenía en salidas de líneas, en los últimos años, ha sido el conjunto de alimentar. Elmismo está compuesto por una bomba principal de múltiples etapas, un variador de velocidad (deacoplamiento hidráulico, un motor, un reductor de velocidades y una bomba auxiliar o bombabúster. [1]. Excesivos valores de vibraciones caracterizaron durante un período de tiempo, laexplotación del conjunto de alimentar, hasta que el estudio y análisis de las representacionesespectrales y temporales de las mediciones de vibraciones tomadas en los apoyos del equipo,permitieron identificar que los defectos que las provocaban provenían de desalineamiento en losárboles del conjunto, manifestándose principalmente en valores de amplitudes altos del segundoarmónico.Luego de un estudio se llegó a la conclusión de que la desalineación era debido al incorrectoproceso de alineación en frío, ya que, hasta la fecha no se tenían en cuenta las dilataciones quesufrían los equipos en condiciones normales de trabajo, esta corrección se describe de forma brevey concisa en el siguiente trabajo, determinado los valores a los cuales se debe alinear este equipo.Palabras claves: desalineación, vibraciones, bomba de múltiples etapas, central termoeléctrica.________________________________________________________________________AbstractIn works done by the author about needs in auxiliary turbine equipment, in an electric powerstation of 125 Mw (Czechoslovak made, it was detected that one of the greatest incidence over theunit line output in these last years was given by the group of feeding water to de boilers. This groupconsisted of the following pieces of equipment: a principal pump, a velocity changer (hydrauliccoupled, a motor, a velocity reducer, and an

  12. Auto Mechanics. Heavy Equipment. Small Engines.

    Science.gov (United States)

    Finnerty, Kathy

    Developed for use in auto mechanics, Heavy Equipment Repair and Operation (HERO), and small engines programs, these study guides and supplemental worksheets cover operating principles, lubrication, cooling system, ignition circuit and electrical system, and fuel system. The worksheets and guide questions are phrased to emphasize key points…

  13. Thermal analysis and control of electronic equipment

    Science.gov (United States)

    Kraus, A. D.; Bar-Cohen, A.

    The application of thermal control techniques to the cooling of electronic components is examined from theoretical and practical points of view. The electronic-thermal-control (ETC) problem and the physical and conceptual restraints on its solution are characterized, with a focus on the goal of system reliability. The fundamentals of heat transfer and fluid mechanics are discussed, including steady-state and transient conduction, convection, radiation, phase-change processes, contact resistance, heat exchangers, air handling, and dimensional analysis. Mathematical models and empirical correlations are explored for such ETC techniques as direct air cooling, extended surfaces, cold plates, immersion cooling, heat pipes, and thermoelectric coolers. Specific ETC applications to inertial equipment, transistors, vacuum tubes, microwave equipment, microelectronics, and printed-circuit boards are considered.

  14. 考虑设备使用安全性的空冷支架结构体系基于位移的抗震设计方法研究%STUDY OF DISPLACEMENT-BASED DESIGN METHOD OF AIR-COOLED CONDENSER STRUCTURE CONSIDERING EQUIPMENT SAFETY

    Institute of Scientific and Technical Information of China (English)

    代慧娟; 白国良; 王博; 薛冯; 李红星

    2015-01-01

    The existing seismic design methods of air-cooled condenser structure do not meet the“investment benefit”criterion because they do not consider the safety of the equipment in earthquake.Through the experimental study on the seismic performance of the structure, performance levels and quantified values of the structure were given, which were suitable for the structure-equipment coupled system, the design methods and steps were established.Finally, displacement-based seismic design method was used to analyze a 1 000 MW air-cooled condenser structure, and the nonlinear dynamic time history analysis was taken for validation.The results showed that displacement-based seismic design method was reasonable.%现有的空冷支架结构抗震设计方法没有明确考虑设备在地震中的使用安全性,不符合“投资效益”准则。通过空冷支架结构的抗震性能试验研究,给出适合该类结构-设备耦合体系在地震作用下的性能水平,提出考虑设备使用安全性的空冷支架结构抗震性能目标量化值,并建立一种适用于该类结构体系的基于位移的抗震设计方法和步骤。最后,以某1000 MW空冷支架结构为例进行基于位移的抗震设计,并采用非线性动力时程分析对提出的基于位移的设计方法进行验证。结果表明,提出的基于位移的抗震设计方法较为合理。

  15. Passive Cooling of Body Armor

    Science.gov (United States)

    Holtz, Ronald; Matic, Peter; Mott, David

    2013-03-01

    Warfighter performance can be adversely affected by heat load and weight of equipment. Current tactical vest designs are good insulators and lack ventilation, thus do not provide effective management of metabolic heat generated. NRL has undertaken a systematic study of tactical vest thermal management, leading to physics-based strategies that provide improved cooling without undesirable consequences such as added weight, added electrical power requirements, or compromised protection. The approach is based on evaporative cooling of sweat produced by the wearer of the vest, in an air flow provided by ambient wind or ambulatory motion of the wearer. Using an approach including thermodynamic analysis, computational fluid dynamics modeling, air flow measurements of model ventilated vest architectures, and studies of the influence of fabric aerodynamic drag characteristics, materials and geometry were identified that optimize passive cooling of tactical vests. Specific architectural features of the vest design allow for optimal ventilation patterns, and selection of fabrics for vest construction optimize evaporation rates while reducing air flow resistance. Cooling rates consistent with the theoretical and modeling predictions were verified experimentally for 3D mockups.

  16. Magnetic cooling. The future or utopia?; Magnetische koeling. Toekomst of utopie?

    Energy Technology Data Exchange (ETDEWEB)

    Krosse, L.; Vermeeren, R.J.F.; Verwoerd, M. [Sectie Thermische en Fysische Processen, TNO Milieu, Energie en Procesinnovatie TNO-MEP, Apeldoorn (Netherlands)

    2004-10-01

    In accordance with the Kyoto agreement the Netherlands have the ambition to reduce the greenhouse gas emissions by 50 Mton CO2-eq. during 2008-2012, compared to 1990-1995. In the field of refrigeration still a lot of greenhouse gases are being used. One option to reduce the emission of greenhouse gases is to apply an alternative refrigeration technology like magnetic cooling. Magnetic cooling is based on the reversible magneto-caloric effect (MCE). Cooling can be obtained by magnetising and demagnetising MCE-materials with permanent magnets, so very little electrical energy is needed. Furthermore, any fluid, such as water or air can be used as the heat transfer medium. Among the advantages of magnetic cooling are: silent operation, application of environmentally benign heat transfer media and energy efficiency. On the other hand it is stilt an immature technology, unknown by most manufactures, and multiple step systems are needed to bridge a sufficient temperature gradient at acceptable cooling capacities. In this study a number of system concepts were identified for magnetic cooling in conventional cooling applications such as domestic refrigerators, cabinets, mobile air-conditioners and stationary airconditioners. At this stage of the development it is essential that the feasibility of the concepts wilt be experimentally validated. Furthermore, the MCE-material research at the universities needs to be followed closely, because it will bring better systems within reach. [Dutch] In overeenstemming met de afspraken gemaakt op de klimaatconferentie in Kyoto streeft Nederland na een reductie van broeikasgas emissies met 50 Mton CO2-eq. in de periode 2008-2012 ten opzichte van 1990-1995. Binnen de koudetechniek worden nog veel broeikasgassen (HFK's) gebruikt, waarvan een deel geemitteerd wordt. Een optie om deze emissies te beperken, is het toepassen van een alternatieve koeltechnologie: magnetische koeling. Magnetische koeling is gebaseerd op het verschijnsel dat

  17. Development of Cooling Process Control Technique in Hot Strip Mill

    Institute of Scientific and Technical Information of China (English)

    HAN Bin; LIU Xiang-hua; WANG Guo-dong; SHE Guang-fu

    2005-01-01

    In order to ensure required mechanical properties of steel strip, various innovations in the cooling process control on the run-out table of a hot strip mill were actively promoted. The recent progress of process mathematical model and the new cooling strategy and equipment were discussed. The computer control system of high performance was introduced. The development trend in cooling process control was given.

  18. Equipment. Out of order.

    Science.gov (United States)

    Connolly, C

    2000-08-17

    The NHS has underinvested in equipment for more than 20 years. Most hospitals have inadequate equipment inventories. More than half the anaesthetic machines in use are more than five years old and should be replaced. Almost a fifth of the equipment used in cancer treatment is obsolete. Current accounting systems act as a disincentive to replacing old equipment.

  19. Hybrid radiator cooling system

    Science.gov (United States)

    France, David M.; Smith, David S.; Yu, Wenhua; Routbort, Jules L.

    2016-03-15

    A method and hybrid radiator-cooling apparatus for implementing enhanced radiator-cooling are provided. The hybrid radiator-cooling apparatus includes an air-side finned surface for air cooling; an elongated vertically extending surface extending outwardly from the air-side finned surface on a downstream air-side of the hybrid radiator; and a water supply for selectively providing evaporative cooling with water flow by gravity on the elongated vertically extending surface.

  20. AC Test Chambers

    Data.gov (United States)

    Federal Laboratory Consortium — The Psychrometric Test Chamber’s primary purpose is to evaluate the performance of split type central air conditioners and heat pumps in the cooling capacity range...

  1. Tehnilised stiilinäited / Margit Aedla

    Index Scriptorium Estoniae

    Aedla, Margit, 1970-

    2007-01-01

    Tutvustatakse LG Art Cool Air Conditioner'i, Electroluxi Global Design sarja sisseehitatavaid tooteid, Zanussi pliiti Teo ja pesumasinat Zoe ning 2007. a. iF disainiauhinna võitnud LG monitiri Fantasy ja LG mobiiltelefoni Chocolate (KG810)

  2. Dry skin - self-care

    Science.gov (United States)

    ... moisture Hot, dry air in desert environments Air conditioners that cool the air and remove moisture Taking ... scrubbing your skin. Shave right after bathing, when hair is soft. Wear soft, comfortable clothing next to ...

  3. Tehnilised stiilinäited / Margit Aedla

    Index Scriptorium Estoniae

    Aedla, Margit, 1970-

    2007-01-01

    Tutvustatakse LG Art Cool Air Conditioner'i, Electroluxi Global Design sarja sisseehitatavaid tooteid, Zanussi pliiti Teo ja pesumasinat Zoe ning 2007. a. iF disainiauhinna võitnud LG monitiri Fantasy ja LG mobiiltelefoni Chocolate (KG810)

  4. Progress of the Water Cooling System for CYCIAE-100

    Institute of Scientific and Technical Information of China (English)

    LI; Zhen-guo; WU; Long-cheng; LIU; Geng-guo

    2012-01-01

    <正>According to the general construction schedule of the BRIF project, the water cooling system for CYCIAE-100 has achieved a significant progress in 2012, its progress can be summarized as follows. 1) Inside wiring of 7 water distribution cabinets were completed. 2) Manufacturer selection of circulating water cooling unit and deionized water production equipment was decided after market survey and bidding process. The contracts were formally signed in February. The deionized water production equipment was ready in May and the circulating water cooling

  5. Central cooling: absorptive chillers

    Energy Technology Data Exchange (ETDEWEB)

    Christian, J.E.

    1977-08-01

    This technology evaluation covers commercially available single-effect, lithium-bromide absorption chillers ranging in nominal cooling capacities of 3 to 1,660 tons and double-effect lithium-bromide chillers from 385 to 1,060 tons. The nominal COP measured at operating conditions of 12 psig input steam for the single-effect machine, 85/sup 0/ entering condenser water, and 44/sup 0/F exiting chilled-water, ranges from 0.6 to 0.65. The nominal COP for the double-effect machine varies from 1.0 to 1.15 with 144 psig entering steam. Data are provided to estimate absorption-chiller performance at off-nominal operating conditions. The part-load performance curves along with cost estimating functions help the system design engineer select absorption equipment for a particular application based on life-cycle costs. Several suggestions are offered which may be useful for interfacing an absorption chiller with the remaining Integrated Community Energy System. The ammonia-water absorption chillers are not considered to be readily available technology for ICES application; therefore, performance and cost data on them are not included in this evaluation.

  6. The ATLAS IBL CO2 Cooling System

    CERN Document Server

    Verlaat, Bartholomeus; The ATLAS collaboration

    2016-01-01

    The Atlas Pixel detector has been equipped with an extra B-layer in the space obtained by a reduced beam pipe. This new pixel detector called the ATLAS Insertable B-Layer (IBL) is installed in 2014 and is operational in the current ATLAS data taking. The IBL detector is cooled with evaporative CO2 and is the first of its kind in ATLAS. The ATLAS IBL CO2 cooling system is designed for lower temperature operation (<-35⁰C) than the previous developed CO2 cooling systems in High Energy Physics experiments. The cold temperatures are required to protect the pixel sensors for the high expected radiation dose up to 550 fb^-1 integrated luminosity. This paper describes the design, development, construction and commissioning of the IBL CO2 cooling system. It describes the challenges overcome and the important lessons learned for the development of future systems which are now under design for the Phase-II upgrade detectors.

  7. Guide Manual of Cooling Methods for Electronic Equipment

    Science.gov (United States)

    1955-03-31

    in. of mercury /2.036) t is in OF. It is important to note that equations (41) and (42) are the two basic equations which enter into heat transfer...mechanical deterioration with time. Ultimately, a short circuit occurs and subsequent" cremation " re- sults. Nith class A insulation, for example...2,4 Magnesium 1.75 .025 I? I 2048 ,0083 37.6 35.8 20,000 Manganes e 8.0 .... 2246 3. 52 ..... .... .... ...... Mercury 13,58 .033 -37.97 680 .0182 1,8

  8. Procedures for Calculating Residential Dehumidification Loads

    Energy Technology Data Exchange (ETDEWEB)

    Winkler, Jon [National Renewable Energy Lab. (NREL), Golden, CO (United States); Booten, Chuck [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-06-01

    Residential building codes and voluntary labeling programs are continually increasing the energy efficiency requirements of residential buildings. Improving a building's thermal enclosure and installing energy-efficient appliances and lighting can result in significant reductions in sensible cooling loads leading to smaller air conditioners and shorter cooling seasons. However due to fresh air ventilation requirements and internal gains, latent cooling loads are not reduced by the same proportion. Thus, it's becoming more challenging for conventional cooling equipment to control indoor humidity at part-load cooling conditions and using conventional cooling equipment in a non-conventional building poses the potential risk of high indoor humidity. The objective of this project was to investigate the impact the chosen design condition has on the calculated part-load cooling moisture load, and compare calculated moisture loads and the required dehumidification capacity to whole-building simulations. Procedures for sizing whole-house supplemental dehumidification equipment have yet to be formalized; however minor modifications to current Air-Conditioner Contractors of America (ACCA) Manual J load calculation procedures are appropriate for calculating residential part-load cooling moisture loads. Though ASHRAE 1% DP design conditions are commonly used to determine the dehumidification requirements for commercial buildings, an appropriate DP design condition for residential buildings has not been investigated. Two methods for sizing supplemental dehumidification equipment were developed and tested. The first method closely followed Manual J cooling load calculations; whereas the second method made more conservative assumptions impacting both sensible and latent loads.

  9. Evolution of cool-roof standards in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Akbari, Hashem; Akbari, Hashem; Levinson, Ronnen

    2008-07-11

    Roofs that have high solar reflectance and high thermal emittance stay cool in the sun. A roof with lower thermal emittance but exceptionally high solar reflectance can also stay cool in the sun. Substituting a cool roof for a noncool roof decreases cooling-electricity use, cooling-power demand, and cooling-equipment capacity requirements, while slightly increasing heating-energy consumption. Cool roofs can also lower citywide ambient air temperature in summer, slowing ozone formation and increasing human comfort. Provisions for cool roofs in energy-efficiency standards can promote the building- and climate-appropriate use of cool roofing technologies. Cool-roof requirements are designed to reduce building energy use, while energy-neutral cool-roof credits permit the use of less energy-efficient components (e.g., larger windows) in a building that has energy-saving cool roofs. Both types of measures can reduce the life-cycle cost of a building (initial cost plus lifetime energy cost). Since 1999, several widely used building energy-efficiency standards, including ASHRAE 90.1, ASHRAE 90.2, the International Energy Conservation Code, and California's Title 24 have adopted cool-roof credits or requirements. This paper reviews the technical development of cool-roof provisions in the ASHRAE 90.1, ASHRAE 90.2, and California Title 24 standards, and discusses the treatment of cool roofs in other standards and energy-efficiency programs. The techniques used to develop the ASHRAE and Title 24 cool-roof provisions can be used as models to address cool roofs in building energy-efficiency standards worldwide.

  10. Common NICU Equipment

    Science.gov (United States)

    ... newborn intensive care unit (NICU) > Common NICU equipment Common NICU equipment E-mail to a friend Please ... Baby Caring for your baby Feeding your baby Common illnesses Family health & safety Complications & Loss Pregnancy complications ...

  11. Liquid-Cooled Garment

    Science.gov (United States)

    1977-01-01

    A liquid-cooled bra, offshoot of Apollo moon suit technology, aids the cancer-detection technique known as infrared thermography. Water flowing through tubes in the bra cools the skin surface to improve resolution of thermograph image.

  12. Cleaning device for cooling elements of a dry cooling tower consisting of finned tubes

    Energy Technology Data Exchange (ETDEWEB)

    Kelp, F.

    1980-02-07

    A nozzle housing is set on to the cooling elements which is equipped with intermediate walls as air guides. A compressed air connection and a suction air connection can be moved vertically in the nozzle housing by a transport spindle. There is a measuring device for dust loading between the two connections.

  13. [Equipment for spray-freezing in ophthalmology].

    Science.gov (United States)

    Anders, M; Matthes, R

    1991-05-01

    The authors discuss the theoretical background of the method of spray/freezing for destructive processes and their advantages. They demonstrate a cryo-apparatus IKG 3 for liquid nitrogen which is part of the Dresden equipment and was elaborated by the department for cryomedicine of the "Carl Gustav Carus" Academy in cooperation with the Technical University in Dresden. The apparatus produces a fine dispensable spray of the cooling mixture and permits treatment even of small tissue areas.

  14. Stochastic cooling in RHIC

    Energy Technology Data Exchange (ETDEWEB)

    Brennan,J.M.; Blaskiewicz, M. M.; Severino, F.

    2009-05-04

    After the success of longitudinal stochastic cooling of bunched heavy ion beam in RHIC, transverse stochastic cooling in the vertical plane of Yellow ring was installed and is being commissioned with proton beam. This report presents the status of the effort and gives an estimate, based on simulation, of the RHIC luminosity with stochastic cooling in all planes.

  15. DEVELOPMENT OF A LINEAR COMPRESSOR FOR AIR CONDITIONERS AND HEAT PUMPS

    Science.gov (United States)

    The report discusses the design, building, testing, and delivering to the Environmental Protection Agency of a linear compressor for operation in a 3.0- ton (10.5 kW) residential air-conditioning and heat pumping system. The compressor design evolved from a linear resonant piston...

  16. Solar Powered Liquid Desiccant Air Conditioner for Low-Electricity Humidity Control

    Science.gov (United States)

    2012-07-01

    manufacturers in the United States. The first demonstration of a commercial LDAC system is being evaluated at the Coral Reef Fitness and Sports...LDAC systems is being installed at the Coral Reef Fitness and Sports Center on Andersen AFB in Guam. A 6000-cfm conditioner was designed for this...demand is highest, leading to increased pollution , excessive investment in standby generation capacity, and poor utilization of peaking assets. This

  17. Air Conditioner Charging. Automotive Mechanics. Air Conditioning. Instructor's Guide [and] Student Guide.

    Science.gov (United States)

    Spignesi, B.

    This instructional package, one in a series of individualized instructional units on automobile air conditioning, consists of a student guide and an instructor guide dealing with air conditioning charging. Covered in the module are checking the air conditioning system for leaks, checking and adding refrigerant oil as needed, evacuating the system,…

  18. Gohieria fusca (Acari: Astigmata) found in the filter dusts of air conditioners in China.

    Science.gov (United States)

    Li, Chaopin; Zhan, Xiaodong; Zhao, Jinhong; Wei, Guo

    2014-10-06

    Objetivo: La Gohieria fusca (Oudemans, 1902) se reproduce en la harina de trigo, arroz, maíz, piensos, salvado de trigo y los medicamentos a base de hierbas, además de en otros productos almacenados; este ácaro puede tener una reactividad cruzada de leve a moderada con alérgenos de los ácaros del polvo domésticos, una importante fuente de alérgenos de interior asociada al asma y otras afecciones alérgicas. Los sistemas de aire acondicionado son indispensables en edificios públicos y civiles, y las pantallas de estos aparatos son los lugares donde más se acumula el polvo. Se realizó este estudio con el fin de investigar si la Gohieria fusca puede reproducirse en las pantallas de los acondicionadores de aire instalados en espacios públicos o viviendas en la ciudad de Wuhu, provincia de Anhui, China. Métodos: Se recogieron 430 muestras de polvo de los filtros de los sistemas de aire acondicionado en la cafeterías de centros educativos, mercados, hoteles y edificios civiles entre junio y septiembre de 2013, y se aisló la Gohieria fusca de dichas muestras. Resultados: Los resultados indicaron que la Gohieria fusca estaba presente en 98 de las 430 muestras (22,79%), y la tasa de reproducción fue significativa en los filtros del aire acondicionado de diferentes espacios (c2=18.294, P.

  19. Value Engineering Study of Standard Family of Military Horizontal and Vertical Air Conditioners.

    Science.gov (United States)

    1988-01-29

    Jeff Nebel Graham Company Box 23880 8800 West Bradley Road Milkwaukee, Wisconsin 53223(414) 355-8800 Terry Gulbrandsen REP: for Emerson Electric Harmon...Mitzubishi Of Washington, Inc. 300 Swann Avenue Alexandria, VA. 22301 Attention: Carl Godwin (703) 548-2045 Central Power Company 27495 Diaz Road...41042 Attention: Rolf Tonseth * *AI~ilREFERENCEYEPLY 081-87 Carl E. 3) 960-4600, Ext. 579 -"IJVE NUMBER MUST APPEAR ON ALL QUOTATIONS PLEASE QUOl THIS

  20. Oil Return Measurements In A Unitary Split System Air Conditioner Using Different Refrigerant Mixtures

    OpenAIRE

    Feichter, Gabriel A.; Eckhard A. Groll; Kurtulus, Orkan; Meng, Ben

    2016-01-01

    The aim of the study presented in this paper is an experimental investigation of the oil return characteristics of alternative refrigerants for residential air conditioning systems using R22. Due to the phase-out of HCFC refrigerants, the production of R22 will be stopped by the year 2020. In some cases of vapor compression systems installed in the field, it will be necessary to replace the R22 with alternative drop-in refrigerants as a part of maintenance procedures. Since R22 system typical...

  1. Air Conditioner Charging. Automotive Mechanics. Air Conditioning. Instructor's Guide [and] Student Guide.

    Science.gov (United States)

    Spignesi, B.

    This instructional package, one in a series of individualized instructional units on automobile air conditioning, consists of a student guide and an instructor guide dealing with air conditioning charging. Covered in the module are checking the air conditioning system for leaks, checking and adding refrigerant oil as needed, evacuating the system,…

  2. Preparation of nano-sized hydrophilic aluminum fins coating materials for air conditioner

    Institute of Scientific and Technical Information of China (English)

    陈志明; 韩峰; 邵利

    2002-01-01

    Semicontinuous seeded emulsion copolymerization of acrylic acid, acrylamide and divinylbenzene was carried out at 80℃ with ammonium persulphate as the initiator and the polyether with comb configuration as the emulsifier to prepare approximately mono-dispersed nano-sized polymer particles with average diameter 90nm. The particles were used to combine with special polyether and de-ionized water was added to obtain nano-sized hydrophilic aluminum fins coating materials with solid content of 10%. The aluminum fins were coated with the materials to get the film showing self-assembly properties in some degree. The obtained hydrophilic fins have contact angles <5° with de-ionized water, minimum value 0°, after 4 cycles of wet and dry, contact angles <10° with de-ionized water.

  3. Experimental investigation on a solid desiccant system integrated with a R407C compression air conditioner

    Energy Technology Data Exchange (ETDEWEB)

    Fatouh, M.; Mostafa, A. [Dept. of Mechanical Power Engineering, Faculty of Engineering, El-Mattaria (Helwan Univ.), Masaken El-Helmia P.O., Cairo 11718 (Egypt); Ibrahim, Talaat A. [Dept. of Mechanical Power Engineering, Faculty of Engineering, El-Mattaria (Helwan Univ.), Masaken El-Helmia P.O., Cairo 11718 (Egypt); King Saud Univ., P.O. 70908, 11577 Riyadh (Saudi Arabia)

    2009-10-15

    In the present work, experimental performance data of a solid desiccant based hybrid air conditioning system are presented. The system consists of a packed bed solid desiccant integrated with a R407C conventional vapor compression refrigeration system. Experiments are carried out during dehumidification operation mode for various operating parameters such as; desiccant mass on shelves (5, 10 and 15 kg), air mass flow rate (7.4 and 10.2 kg/min), shelves number (1, 2 and 3) and three values of shelves span (7, 14 and 28 cm) at evaporator air inlet conditions of 28 C DBT and 66% RH, condenser air inlet volume flow rate of 850 m{sup 3}/h and temperature of 35 C. The reactivation of the desiccant at different regeneration temperatures and air flow rates as well as desiccant masses is also investigated. During the dehumidification mode, the average system coefficient of performance increases by 6.2% and 1.61% when the mass of desiccant increases from 5 to 10 kg and from 10 to 15 kg, respectively. The enhancement in the coefficient of performance is 6.2% due to increasing the air mass flow rate from 7.4 to 10.2 kg/min. Increasing both shelves number and span yields to a reduction in the adsorption rate that can be extracted by the desiccant material in the ranges of considered operating conditions. The regeneration temperature and the air flow rate of regeneration have significant effects on the reactivation process. It was found that, with increasing the mass flow rate of regenerated air from 7.4 to 10.2 kg/min produces a reduction in regeneration time by 87.5% and an augmentation in the desorption rate by 16% after 10 min of regeneration. In addition, with escalating the regeneration temperature from 45 to 55 C, the reactivation time reduces by 25%. Reported results revealed that solid desiccant based hybrid air conditioning system reduces the compressor electric power and the number of electric unit (kW h) by 10.2%. (author)

  4. A close look at air-conditioner air-filters; Klimaanlagen-Luftfilter unter der Lupe

    Energy Technology Data Exchange (ETDEWEB)

    Reichert, F.

    2006-07-01

    This article presents the findings of a long-term study made on air-filters. Results of measurements made according to EN 779 under ideal conditions are discussed and their use as a basis for the assessment of performance in practice is looked at critically. The two-year, long-term study follows up earlier studies on the hygiene of air-conditioning systems. Real-life installations with F7 and F9 filters were tested. Measurement methods used are discussed and the characteristics of the filters with respect to micro-organisms looked at. Various factors considered are examined and alternative filter combinations are briefly discussed. The results are presented in graphical form. EN 779-specific tests made and the results obtained are discussed.

  5. Evaluation of the air conditioner quality in the health care sector; Uitvoeringskwaliteit luchtbehandelingsunit in de zorgsector

    Energy Technology Data Exchange (ETDEWEB)

    Van Haperen, K. [Carrier Holland Heating, Waalwijk (Netherlands)

    2009-02-15

    To specify the required quality standards for an air conditioning unit, the user must critically consider a number of criteria in order to decide what design and construction standards the unit and its built in components must meet; and these will depend on the application. The principle criteria involved are undoubtedly energy consumption, durability, reliability and maintenance costs. The choice of the manufacturer or supplier also plays an important part. [Dutch] Voor het vastleggen van het gewenste kwaliteitsniveau van een luchtbehandelingsunit dient de eindgebruiker een aantal zaken kritisch te overwegen om te kunnen beslissen aan welke ontwerp- en constructie-eisen de unit met ingebouwde componenten moet voldoen; e.e.a, afhankelijk van de toepassing. De voor de zorgsector belangrijkste toetsingscriteria hierbij zijn ongetwijfeld energiegebruik, duurzaamheid, betrouwbaarheid en onderhoudskosten. De keuze van de fabrikant/leverancier speelt hierin een belangrijke rol.

  6. Local Voltage Support from Distributed Energy Resources to Prevent Air Conditioner Motor Stalling

    Energy Technology Data Exchange (ETDEWEB)

    Baone, Chaitanya A [ORNL; Xu, Yan [ORNL; Kueck, John D [ORNL

    2010-01-01

    Microgrid voltage collapse often happens when there is a high percentage of low inertia air-conditioning (AC) motors in the power systems. The stalling of the AC motors results in Fault Induced Delayed Voltage Recovery (FIDVR). A hybrid load model including typical building loads, AC motor loads, and other induction motor loads is built to simulate the motoring stalling phenomena. Furthermore, distributed energy resources (DE) with local voltage support capability are utilized to boost the local bus voltage during a fault, and prevent the motor stalling. The simulation results are presented. The analysis of the simulation results show that local voltage support from multiple DEs can effectively and economically solve the microgrid voltage collapse problem.

  7. The plaster plate becomes a air-conditioner; La plaque de platre se fait climatiseur

    Energy Technology Data Exchange (ETDEWEB)

    Lucat, Th.

    2005-09-01

    BASF company, in association with Knauf, has developed a plaster plate capable to regulate the indoor temperature of a room during summer time. A paraffin-based (wax) phase change material, named Micronal, is included in the plater to store energy during the day and to release it during the night. The lifetime of the phase change material is at least 30 years without loss of efficiency. Short paper. (J.S.)

  8. Revisiting solar-powered ejector air conditioner - the greener the better

    Energy Technology Data Exchange (ETDEWEB)

    Arbel, A. [Institute of Agricultural Engineering, Bet-Dagan (Israel). Department of Central Agriculture and Environmental Engineering; Sokolov, M. [Tel-Aviv University, Ramat-Aviv (Israel). Faculty of Engineering, Department of Fluid Mechanics and Heat Transfer

    2004-07-01

    Previous work on solar-powered ejector air-conditioning system is updated for refrigerant R-142b to replace R-114 as the working fluid. Such update offers viable alternative to the system, which previously used the now banned R-114. Cycles with and without compression enhancements are analyzed to produce variety of systems to suit variety of local considerations. The result of the analysis and simulation introduces not only an environmentally compatible but also a more efficient system. (author)

  9. High energy efficiency desiccant assisted automobile air-conditioner and its temperature and humidity control system

    Energy Technology Data Exchange (ETDEWEB)

    Nagaya, K. [Department of Mechanical Engineering, Gunma University Kiryu, Gunma 376-8515 (Japan)]. E-mail: nagaya@me.gunma-u.ac.jp; Senbongi, T. [Department of Mechanical Engineering, Gunma University Kiryu, Gunma 376-8515 (Japan); Li, Y. [Department of Mechanical Engineering, Gunma University Kiryu, Gunma 376-8515 (Japan); Zheng, J. [Department of Mechanical Engineering, Gunma University Kiryu, Gunma 376-8515 (Japan); Murakami, I. [Department of Mechanical Engineering, Gunma University Kiryu, Gunma 376-8515 (Japan)

    2006-10-15

    The energy efficiency is of importance in air conditioning systems for automobiles. The present article provides a new type air conditioning system for automobiles in which energy loss is small in comparison with the previous system. In the system, a desiccant is installed in the air conditioning system for controlling both temperature and humidity. The control is performed by an electromagnetic control valve, which controls an inclination of the rotating plate of a compressor. It is difficult to control both temperature and humidity precisely, because there are some delays in the control due to the time of heat exchange and that of coolant flow from the actuator (electromagnetic valve) to the evaporator. In order to have precise control, this article also presents a method of control with consideration of control delays. The energy of our system is compared with that in the previous conventional system in the same condition. It is shown that our controlled results and energy efficiency are better than those in the previous system.

  10. Practical experiments on an adsorption air conditioner powered by exhausted heat from a diesel locomotive

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Y.Z.; Wang, R.Z.; Jianzhou, S.; Xu, Y.X.; Wu, J.Y. [Shanghai Jiao Tong University (China). Institute of Refrigeration and Cryogenics

    2004-05-01

    Experimental studies on the practical performance of an adsorption air conditioning system powered by exhausted heat from a diesel locomotive are presented. The system incorporates one adsorbent bed and utilizes zeolite-water as a working pair to provide chilled water for conditioning the air in the driver's cab of the locomotive. Performance tests under different running conditions have been carried out. Experimental results show that the suggested adsorption system is technically feasible and can be applied for space air conditioning of the locomotive driver's cab, except the case when the locomotive tracts a way train. The average refrigeration power ranging from 3.0 to 4.2 kW has been obtained under typical running conditions. (author)

  11. Decentralized ventilation. Air conditioner of the future; Gedecentraliseerde ventilatie. De luchtbehandelingsinstallatie van de toekomst

    Energy Technology Data Exchange (ETDEWEB)

    Young, T. [Swegon Ltd, Kvaenum (Sweden); Hartmans, J.L.F. [Bergschenhoek, Berkel Rodenrijs (Netherlands)

    2005-11-01

    An overview is given of arguments to apply decentralized air conditioning systems instead of large central ventilation and air conditioning systems. It appears that savings can be realized with respect to investment, exploitation and the use of energy. [Dutch] Bij het ontwerpen van een ventilatie en/of luchtbehandelingssysteem voor gebouwen ging lange tijd de voorkeur uit naar het plaatsen van grote luchtbehandelingskasten die de ventilatie van het overgrote deel van het gebouw moesten regelen. De achterliggende gedachte hiervan was dat dit het goedkoopst zou zijn. Er zijn tal van redenen te bedenken waarom met een gedecentraliseerde luchtbehandelings-installatie veel beter op de investerings- en exploitatiekosten kan worden bespaard en een grotere efficientie van de energiebronnen kan worden bereikt. Ook kunnen in het ontwerp van de installatie bepaalde factoren worden opgenomen die bijdragen aan een veel beter totaal resultaat.

  12. Segregated residential air conditioner load model behavior with temperature and humidity

    Energy Technology Data Exchange (ETDEWEB)

    Belhadj, C.A. [King Fahd Univ. of Petroleum and Minerals, Dhahran (Saudi Arabia). Dept. of Electrical Engineering; El Ferik, S. [King Fahd Univ. of Petroleum and Minerals, Dhahran (Saudi Arabia). Dept. of Systems Engineering

    2005-07-01

    This paper considered the impact of outdoor weather conditions on air conditioning residential loads in Saudi Arabia. Humidity and temperature loads were analyzed separately. Weather data were collected for a period of 6 months at a typical household in the eastern region of Saudi Arabia. Inside and outside temperatures, and electrical variables of the household power system were recorded every 5 minutes. Humidity levels were then divided into 3 different comfort levels. A 3-dimensional analysis of the data was then conducted. Mathematical equations were obtained to represent power usage related to humidity and temperature. A regression model was then used to evaluate the influence of humidity on power loads. Field data were then used to validate the regression model. Results of the study showed that the model was able to accurately predict power consumption profiles related to air conditioning in the region. It was concluded that the division of humidity levels into 3 discrete intervals allowed for an improved understanding of the nonlinear relationship between humidity, temperature, and power demand. 13 refs., 2 tabs., 8 figs.

  13. Solar-Powered, Liquid-Desiccant Air Conditioner for Low-Electricity Humidity Control

    Science.gov (United States)

    2012-11-01

    energy penalty in fan power and requires frequent maintenance to remain effective. Alternatively, the low-flow liquid desiccant uses minimal mist ...65 8.3.4 LDAC Fans and Pumps...27 Table 9. LDAC System Pump and Fan Motor Schedule

  14. Air conditioners and summer maximum electricity consumption in the PD ED Belgrade

    Directory of Open Access Journals (Sweden)

    Vrcelj Nada

    2011-01-01

    Full Text Available The paper presents an analysis of the impact of consumption of air conditioning in the form of daily consumption diagram as well as their impact on the achieved power consumption maximum during the summer period. Three cases were observed, regarding 10 kV cables, that supply with electricity mainly: the commercial sector, residential area that does not use electricity for heating and residential area that uses electricity for winter heating. At the same time the winter maximum in the each of the observed cases, as well as the possibility of exceeding the allowable current loads on the routes of monitored 10 kV cables are analyzed.

  15. COP improvement of refrigerator/freezers, air-conditioners, and heat pumps using nonazeotropic refrigerant mixtures

    Science.gov (United States)

    Westra, Douglas G.

    1993-01-01

    With the February, 1992 announcement by President Bush to move the deadline for outlawing CFC (chloro-fluoro-carbon) refrigerants from the year 2000 to the year 1996, the refrigeration and air-conditioning industries have been accelerating their efforts to find alternative refrigerants. Many of the alternative refrigerants being evaluated require synthetic lubricants, are less efficient, and have toxicity problems. One option to developing new, alternative refrigerants is to combine existing non-CFC refrigerants to form a nonazeotropic mixture, with the concentration optimized for the given application so that system COP (Coefficient Of Performance) may be maintained or even improved. This paper will discuss the dilemma that industry is facing regarding CFC phase-out and the problems associated with CFC alternatives presently under development. A definition of nonazeotropic mixtures will be provided, and the characteristics and COP benefits of nonazeotropic refrigerant mixtures will be explained using thermodynamic principles. Limitations and disadvantages of nonazeotropic mixtures will be discussed, and example systems using such mixtures will be reviewed.

  16. Heat recovery equipment for engines

    Energy Technology Data Exchange (ETDEWEB)

    Segaser, C.L.

    1977-04-01

    The recovery and use of waste heat from prime movers is an important consideration for evaluating an on-site power system, since it is the basic factor that makes possible a substantial increase in fuel-use efficiency. The equipment usually employed to recover waste heat can be categorized as: (a) shell-and-tube type heat exchangers, (b) radiator-type heat exchangers, (c) exhaust gas boilers for the generation of pressurized hot water and/or steam, (d) steam separators, and (e) combined packaged units for ebulliently cooled internal combustion piston engines. The functional requirements and cost considerations involved in applying these devices for the recovery of waste heat from various types of prime-movers considered for application in the ICES Systems Engineering Program are examined.

  17. Laser cooling of solids

    OpenAIRE

    Nemova, Galina

    2009-01-01

    Parallel to advances in laser cooling of atoms and ions in dilute gas phase, which has progressed immensely, resulting in physics Nobel prizes in 1997 and 2001, major progress has recently been made in laser cooling of solids. I compare the physical nature of the laser cooling of atoms and ions with that of the laser cooling of solids. I point out all advantages of this new and very promising area of laser physics. Laser cooling of solids (optical refrigeration) at the present time can be lar...

  18. Renewal of radiological equipment.

    Science.gov (United States)

    2014-10-01

    In this century, medical imaging is at the heart of medical practice. Besides providing fast and accurate diagnosis, advances in radiology equipment offer new and previously non-existing options for treatment guidance with quite low morbidity, resulting in the improvement of health outcomes and quality of life for the patients. Although rapid technological development created new medical imaging modalities and methods, the same progress speed resulted in accelerated technical and functional obsolescence of the same medical imaging equipment, consequently creating a need for renewal. Older equipment has a high risk of failures and breakdowns, which might cause delays in diagnosis and treatment of the patient, and safety problems both for the patient and the medical staff. The European Society of Radiology is promoting the use of up-to-date equipment, especially in the context of the EuroSafe Imaging Campaign, as the use of up-to-date equipment will improve quality and safety in medical imaging. Every healthcare institution or authority should have a plan for medical imaging equipment upgrade or renewal. This plan should look forward a minimum of 5 years, with annual updates. Teaching points • Radiological equipment has a definite life cycle span, resulting in unavoidable breakdown and decrease or loss of image quality which renders equipment useless after a certain time period.• Equipment older than 10 years is no longer state-of-the art equipment and replacement is essential. Operating costs of older equipment will be high when compared with new equipment, and sometimes maintenance will be impossible if no spare parts are available.• Older equipment has a high risk of failure and breakdown, causing delays in diagnosis and treatment of the patient and safety problems both for the patient and the medical staff.• Every healthcare institution or authority should have a plan for medical imaging equipment upgrade or replacement. This plan should look forward a

  19. DEVELOPMENT OF SINGLE-PHASED WATER-COOLING RADIATOR FOR COMPUTER CHIP

    Institute of Scientific and Technical Information of China (English)

    ZENG Ping; CHENG Guangming; LIU Jiulong; YANG Zhigang; SUN Xiaofeng; PENG Taijiang

    2007-01-01

    In order to cool computer chip efficiently with the least noise, a single phase water-cooling radiator for computer chip driven by piezoelectric pump with two parallel-connection chambers is developed. The structure and work principle of this radiator is described. Material, processing method and design principles of whole radiator are also explained. Finite element analysis (FEA) software,ANSYS, is used to simulate the heat distribution in the radiator. Testing equipments for water-cooling radiator are also listed. By experimental tests, influences of flowrate inside the cooling system and fan on chip cooling are explicated. This water-cooling radiator is proved more efficient than current air-cooling radiator with comparison experiments. During cooling the heater which simulates the working of computer chip with different power, the water-cooling radiator needs shorter time to reach lower steady temperatures than current air-cooling radiator.

  20. On the miniaturisation of convenction cooling solutions applicable to portable electronic devices

    OpenAIRE

    Stafford, Jason

    2010-01-01

    peer-reviewed Dimensional restrictions in electronic equipment have resulted in miniaturisation of many existing cooling technologies. In addition, cooling solutions are required to dissipate increased thermal loads to maintain component reliability and user comfort. Fans are widely used in electronics cooling to meet such thermal demands, either in standalone for direct component cooling, or in combination with a heat sink. The thermal performance of such designs when scaled to dimensions...