WorldWideScience

Sample records for conventional screen film

  1. Comparison of digital radiography and conventional film screen radiography

    Energy Technology Data Exchange (ETDEWEB)

    Kalender, W A; Huebener, K H

    1984-01-01

    Parameters of image quality, comprising spacial resolution and contrast, have been determined in the form of a contrast/detail diagram for a digital system (Topogram) and a film-screen system. The digital system was particularly examined concerning its contrast sensitivity in relation to quantum noise. The clinical implications of the comparison of the systems, where evaluated on chest X-rays of 250 patients. Despite lower image sharpness, the digital method is already able to produce equivalent or better diagnostic results in certain circumstances. The advantages and disadvantages of both systems are discussed in detail.

  2. A comparison of digital radiography and conventional film screen radiography

    International Nuclear Information System (INIS)

    Kalender, W.A.; Huebener, K.H.; Tuebingen Univ.

    1984-01-01

    Parameters of image quality, comprising spacial resolution and contrast, have been determined in the form of a contrast/detail diagram for a digital system (Topogram) and a film-screen system. The digital system was particularly examined concerning its contrast sensitivity in relation to quantum noise. The clinical implications of the comparison of the systems, where evaluated on chest X-rays of 250 patients. Despite lower image sharpness, the digital method is already able to produce equivalent or better diagnostic results in certain circumstances. The advantages and disadvantages of both systems are discussed in detail. (orig.) [de

  3. Clinical comparison of conventional and rare earth screen-film systems for cephalometric radiographs

    International Nuclear Information System (INIS)

    Kaugars, G.E.; Fatouros, P.

    1982-01-01

    This study compared cephalometric and P-A skull films taken with conventional (CaWO4) screens and rare earth screens. Patient exposure was reduced by 17 to 55 percent on two different x-ray machines by the use of rare earth screens. Results from 130 clinical evaluations showed that the diagnostic quality of radiographs taken with either system was roughly comparable. This presents a persuasive argument for the use of rare earth screens since the diagnostic quality of the films can be maintained while significantly reducing the patient's exposure to radiation

  4. Comparison of stimulable phosphor technology and conventional screen-film technology in pediatric scoliosis

    International Nuclear Information System (INIS)

    Stringer, D.A.; Cairns, R.A.; Poskitt, K.J.; Bray, H.; Milner, R.; Kennedy, B.

    1994-01-01

    One hundred consecutive patients being investigated for scoliosis were studied using a double cassette containing a conventional film screen and a stimulable phosphor plate. The images were separated, randomised and scored thrice by three radiologists for anatomic structure visualisation. The exposure to the plate and film and repeat rate were measured. Scoliosis angles were comparable on both sets of images, however, visualisation of vertebrae, vertebral end plates, pedicles, spinous processes and other structures were significantly improved (p < 0.0001). Intra- and inter-observer reliability was high with good intraclass correlation. There was a 40% potential exposure reduction, and retakes were decreased from 3 to 0%. We conclude that stimulable phosphor images give better anatomic structure visualisation with potential radiation exposure reduction and lower repeat rate. (orig.)

  5. Detectability of the mediastinal lines : comparison of conventional film-screen radiography and digital radiography

    International Nuclear Information System (INIS)

    Shin, Hye Young; Park, Kyung Joo; Kang, Doo Kyung; Lee, Kang Lai; Han, Chaing Jin; Suh, Jung Ho

    1998-01-01

    Using dynamic range compression (DRC) processing, this study compared the detectability of mediastinal lines by conventional film screen radiography (FS) and by storage phosphor digital radiography (DR). We selected 200 normal consecutive chest radiographs (100 FS, 100 DR); dynamic range compression was applied to DR processing and moving grids were used in both systems. Seven mediastinal lines (left paraspinal, right paraspinal, azygoesophageal, left para-aortic, posterio junctional, anterior junctional and right paratracheal) were scored from 0 point to 3 point (0: not visible, 1 : suspiciously visible, 2 : visible, but not clear, 3: clearly visible) according to visibility and sharpness, as agreed by a radiologist and a resident. The differences between the two modalities were compared and analyzed by chi-square test. DR processed with DRC visualizes mediastinal lines more frequently and clearly than conventional FS, and is therefore thought to be useful for the evaluation of mediastinal diseases. (author). 14 refs., 2 tabs., 2 figs

  6. High-resolution storage phosphor imaging of the chest: Comparison with conventional screen-film systems

    International Nuclear Information System (INIS)

    Fuhrman, C.R.; Good, B.; Feist, J.; Gur, D.; Darby, J.

    1987-01-01

    An experimental high-resolution storage phosphor imaging system (Eastman Kodak) has been used to evaluate the image quality and impact on diagnostic interpretation of storage phosphor images relative to conventional screen-film images of the same patients. The elements of the system include a high-resolution laser scanner (4K X 5K X 12 bit); an image processing system; and a high-resolution (4K X 5K X 12 bit) laser printer. Each case was digitally printed onto film in two different formats: a full-size (14 X 14-inch) and a half-size format of four processed, minified images (7 X 7-inches each). The multiformat image includes an original, an unsharp-masked, a reversed (black bone) unsharp-masked, and a high-contrast unsharp-masked image. The results of this preliminary study (11 cases, eight readers) clearly indicate that after minimal adjustment, radiologists do not object to making diagnoses from minified images. Unsharp masked images were considered preferable to unprocessed images, and processed storage phosphor images were rated significantly better than conventional film images

  7. A comparison of digital luminescence radiography and conventional film/screen techniques in the diagnosis of fractures

    International Nuclear Information System (INIS)

    Fink, U.; Schwerdtfeger, J.; Fink, B.K.; Schaetzl, M.; Reiser, M.

    1996-01-01

    The accuracy of digital luminescence radiography was compared with that of conventional film/screen techniques, using animal preparations and clinical examinations. Fine fissures were made in 8 animal bones and these were examined radiologically. The digital examinations were carried out with and without edge enhancement. 208 patients were examined in a similar way. Film quality and assessment of the fractures were evaluated quantitatively. In no instance did either of the digital methods provide inferior quality when compared with conventional films. ROC analysis for evaluation of fractures in patients, using an experienced radiologist, showed no significant difference between the various methods (ROC areas: Conventional 0.947, digital 0.958, digital with edge enhancement 0.943). With a less experienced observer there were significant advantages for both digital methods (ROC areas: 0.851, 0.886, 0.908). Our investigation has proved that fractures which are difficult to see can be reliably demonstrated by digital luminescence radiography. (orig.) [de

  8. Diagnostic value of digital radiography compared to conventional screen-film system combinations

    International Nuclear Information System (INIS)

    Krug, B.; Zaehringer, M.; Lackner, K.

    1997-01-01

    Digital projection radiography provides digital data in X-ray examinations, which used to be carried out by examinations screen-film system combinations. The technological basis and clinical performances of digital luminescent radiography (DLR) and digital radiography are reviewed. Digital projection radiography does not allow to reduce selenium exposure significantly, compared to screen-film system combinations. Digital luminescent radiography can be used for the entire spectrum of analogous projection radiography the only exception being extremely subtile structural changes. The clinical experiences with digital selenium radiography achieved so far in chest X-rays are promising and the technique is expected to be increasing used in other anatomic regions as well. (orig.) [de

  9. Image quality in conventional film screen system, digital phosphor storage plate mammography in magnification technique and digital mammography in CCD-technique

    International Nuclear Information System (INIS)

    Schulz-Wendtland, R.; Aichinger, U.; Boehner, C.; Dobritz, M.; Bautz, W.; Saebel, M.

    2000-01-01

    Purpose: Comparison of image quality between conventional film screen system, digital phosphor storage plate mammography in magnification technique and digital mammography in CCD-technique. Materials and Methods: Radiograms of a RMI-mammography phantom were acquired using a conventional film screen system, two digital storage plate systems and two digital systems in CCD-technique. Additionally, the radiograms of one digital phosphor storage plate system were post-processed emphasizing contrast and included in the comparison. Results: The detectability of details was the best with the digital mammography in CCD-technique in comparison with the conventional film screen technique resp. digital phosphor storage plate in magnification technique. Conclusions: Based on these results there is the possibility to replace the conventional film screen system by further studies - this has to be confirmed. (orig.) [de

  10. Reduction of radiation dose by using digital luminescence radiography compared to conventional screen film system with grid cassette

    International Nuclear Information System (INIS)

    Heyne, J.P.; Merbold, H.; Neumann, R.; Freesmeyer, M.; Jonetz-Mentzel, L.; Kaiser, W.A.; Sehner, J.

    1999-01-01

    Purpose: How much can the radiation dose be reduced for skull radiography by using digital luminescence radiography (DLR) compared to a conventional screen film system with a grid cassette? Methods and Materials: A skull phantom (3M) was X-rayed in anterior-posterior orientation using both a conventional screen film system with grid cassette and DLR (ADC-70, Agfa). The tube current time product (mAs) was diminished gradually while keeping the voltage constant. The surface entrance dose was measured by a sensor of Dosimax (Wellhoefer). Five investigators evaluated the images by characteristic and critical features, spatial resolution and contrast. Results: The surface entrance dose at 73 kV/22 mAs was 0,432 mGy in conventional screen film system and 0,435 mGy in DLR. The images could be evaluated very well down to an average dose of 71% (0,308 mGy; SD 0,050); sufficient images were obtained down to an average dose of 31% (0,136 mGy; SD 0,065). The resolution of the line pairs were reduced down to a 2 levels depending on the investigator. Contrast was assessed as being very good to sufficient. The acceptance of the postprocessed images (MUSICA-software) was individually different and resultde in an improvement of the assessment of bone structures an contrast in higher dose ranges only. Conclusion: For the sufficient assessment of a possible fracture/of paranasal sinuses/of measurement the skull the dose can be reduced to at least 56% (31%; SD 14,9%)/40% (27%; SD 9,3%)/18% (14%; SD 4,4%). Digital radiography allows question-referred exposure parameters with clearly reduced dose, so e.g. for fracture exclusion 73 kV/12,5 mAs and to skull measurement 73 kV/4 mAs. (orig.) [de

  11. Comparison between a digital scanning system and a conventional screen film system in the full spine radiological procedure in pediatrics

    International Nuclear Information System (INIS)

    Espana, M. L.; Gomez, G.; Romero, A.; Minambres, A.; Albi, G.; Floriano, A.; Rodirguez, A.; Lopez Franco, P.

    2004-01-01

    To compare from both dosimetry and image quality standpoints, a digital scanning system with a conventional screen film system, in the full spine radiological procedure. The standard patient is considered to be 12 years old, and a sample of forty patients referred for full spine radiological procedure has been studied. Gonad shielding has been used in all the patients, and its efficiency has been evaluated. Dosimetric study includes Kerma-area product, and thorax and gonad entrance surface dose. Kerma area product has been measured using a transmission camera, and for entrance surface dose estimation both thermoluminescent dosemeter LiF: Mg, Cu, P and LiF: Mg, Ti have been utilized. Three radiologists have evaluated the image quality according to the degree of fulfilment of the image quality criteria. (Author) 22 refs

  12. A comparison of image quality and dose requirements of a new conventional film-screen system for skeletal radiography

    International Nuclear Information System (INIS)

    Freitag, P.; Gueckel, C.; Fournier, P.J.; Roth, J.; Steinbrich, W.

    1995-01-01

    This paper compares a new film-screen system (FSS) called INSIGHT Skeletal Imaging System with the previously used Lanex/T-MAT G FSS. Using a Bronder phantom, measurements were made of dose, resolution and contrast. 135 skeletal phantom images were assessed in order of quality by six observers. Comparable high resolution film-screen combinations (FSC) showed similar geometric resolution. Comparing high intensifying screens, the new INSIGHT Skeletal Regular FSS showed better resolution than the Lanex medium FSC. Dose reduction for the INSIGHT Skeletal Imaging FSS was 29-56%. The new FSS showed image quality similar to high resolution screens but was significantly better when using high intensifying screens. (orig./MG) [de

  13. Screen-film mammography

    International Nuclear Information System (INIS)

    Logan, W.W.; Janus, J.A.

    1987-01-01

    The development of screen-film mammography has resulted in the re-emergence of confidence, rather than fear, in mammography. When screen-film mammography is performed with state-of-the-art dedicated equipment utilizing vigorous breast compression and a ''soft'' x-ray beam for improved contrast, screen-film images are equivalent or superior to those of reduced-dose xeromammography and superior to those of nonscreen film mammography. Technological aids for conversion from xeromammographic or nonscreen film mammographic techniques to screen-film techniques have been described. Screen-film mammography should not be attempted until dedicated equipment has been obtained and the importance of vigorous compression has been understood

  14. Experimental investigations of image quality in X-ray mammography with conventional screen film system (SFS), digital phosphor storage plate in/without magnification technique (CR) and digital CCD-technique (CCD)

    International Nuclear Information System (INIS)

    Schulz-Wendtland, R.; Aichinger, U.; Boehner, C.; Dobritz, M.; Wenkel, E.; Bautz, W.; Saebel, M.

    2001-01-01

    Comparison of image quality in X-ray mammography between conventional film screen film system (SFS), digital phosphor storage plate in and without magnification technique (CR) and digital CCD-technique (CCD). Radiograms of an RMI-mammography phantom were acquired using a conventional screen film system, three digital storage plate systems and two digital systems in CCD-technique. Additionally the radiograms of one digital phosphor storage plate system were post-processed regarding contrast and included in the comparison. The detectability of details was best with the digital mammography in CCD-technique. After confirming these promising results in clinical studies, digital mammography should be able to replace conventional screen film technique. (orig.)

  15. [The reduction of the radiation dosage by means of storage phosphor-film radiography compared to a conventional film-screen system with a grid cassette on a skull phantom].

    Science.gov (United States)

    Heyne, J P; Merbold, H; Sehner, J; Neumann, R; Freesmeyer, M; Jonetz-Mentzel, L; Kaiser, W A

    1999-07-01

    How much can the radiation dose be reduced for skull radiography by using digital luminescence radiography (DLR) compared to a conventional screen film system with a grid cassette? A skull phantom (3M) was x-rayed in anterior-posterior orientation using both a conventional screen film system with grid cassette and DLR (ADC-70, Agfa). The tube current time product (mAs) was diminished gradually while keeping the voltage constant. The surface entrance dose was measured by a sensor of Dosimax (Wellhöfer). Five investigators evaluated the images by characteristic and critical features, spatial resolution and contrast. The surface entrance dose at 73 kV/22 mAs was 0.432 mGy in conventional screen film system and 0.435 mGy in DLR. The images could be evaluated very well down to an average dose of 71% (0.308 mGy; SD 0.050); sufficient images were obtained down to an average dose of 31% (0.136 mGy; SD 0.065). The resolution of the line pairs were reduced down to 2 levels depending on the investigator. Contrast was assessed as being very good to sufficient. The acceptance of the postprocessed images (MUSICA-software) was individually different and resulted in an improvement of the assessment of bone structures and contrast in higher dose ranges only. For the sufficient assessment of a possible fracture/of paranasal sinuses/of measurement of the skull the dose can be reduced to at least 56% (phi 31%; SD 14.9%)/40% (phi 27%; SD 9.3%)/18% (phi 14%; SD 4.4%). Digital radiography allows question-referred exposure parameters with clearly reduced dose, so e.g. for fracture exclusion 73 kV/12.5 mAs and to skull measurement 73 kV/4 mAs.

  16. The comparative evaluation of film-screen combinations

    International Nuclear Information System (INIS)

    Choi, Gyung Ja; Choi, Syng Kyu

    1988-01-01

    This study was to compare the quality of image by different screen and film combinations. Using the sensitometer measured the speed and average gradient of blue sensitive films and orthochromatic films. The films was combined with rare earth screen LR, Lm, LF and conventional screen OM, OH, XOR, OKa and exposed the stepwedge to impulse 2, 3, 4, 6, 10, 15, 24, 38, 60 and measured the density. The following results were obtained: 1. The density of film and film-screen combinations showed significant difference, then in film-screen combinations was significantly different by the screens than films. 2. The speed of blue sensitive films was little different, the TMG of orthochromatic films producted high speed, and the AX films was high average gradient. 3. The relative speed of film-screen combinations showed significant difference, and was high in the OKa of the conventional screens and in the LR of the rare earth screens, especially that of LR screen in the combination with blue sensitive films was high. 4. The average gradient of film-screen combinations showed no significant difference, and was high in the OKa screen and LR/OG combination, and that of OKa/AX combination was highest. 5. The latitude of film-screen combinations showed significant difference by screens, and was high in the LM screen in combination with blue sensitive films and in the OM screen in combination with orthochromatic films. 6. The subject contrast of film-screen combinations showed significant difference by screen, and was high in the LR screen in combination with blue sensitive AX film and orthochromatic TMG film.

  17. Reduction of radiation dose by using digital luminescence radiography compared to conventional screen film system with grid cassette; Reduktion der Strahlendosis mittels Speicherfolienradiographie im Vergleich zum konventionellen Film-Folien-System mit Rasterkassette am Schaedelphantom

    Energy Technology Data Exchange (ETDEWEB)

    Heyne, J.P.; Merbold, H.; Neumann, R.; Freesmeyer, M.; Jonetz-Mentzel, L.; Kaiser, W.A. [Friedrich-Schiller-Univ. Jena, Inst. fuer Diagnostische und Interventionelle Radiologie (Germany); Sehner, J. [AGFA-Deutschland, Vertriebsgesellschaft (Germany)

    1999-07-01

    Purpose: How much can the radiation dose be reduced for skull radiography by using digital luminescence radiography (DLR) compared to a conventional screen film system with a grid cassette? Methods and Materials: A skull phantom (3M) was X-rayed in anterior-posterior orientation using both a conventional screen film system with grid cassette and DLR (ADC-70, Agfa). The tube current time product (mAs) was diminished gradually while keeping the voltage constant. The surface entrance dose was measured by a sensor of Dosimax (Wellhoefer). Five investigators evaluated the images by characteristic and critical features, spatial resolution and contrast. Results: The surface entrance dose at 73 kV/22 mAs was 0,432 mGy in conventional screen film system and 0,435 mGy in DLR. The images could be evaluated very well down to an average dose of 71% (0,308 mGy; SD 0,050); sufficient images were obtained down to an average dose of 31% (0,136 mGy; SD 0,065). The resolution of the line pairs were reduced down to a 2 levels depending on the investigator. Contrast was assessed as being very good to sufficient. The acceptance of the postprocessed images (MUSICA-software) was individually different and resultde in an improvement of the assessment of bone structures an contrast in higher dose ranges only. Conclusion: For the sufficient assessment of a possible fracture/of paranasal sinuses/of measurement the skull the dose can be reduced to at least 56% (31%; SD 14,9%)/40% (27%; SD 9,3%)/18% (14%; SD 4,4%). Digital radiography allows question-referred exposure parameters with clearly reduced dose, so e.g. for fracture exclusion 73 kV/12,5 mAs and to skull measurement 73 kV/4 mAs. (orig.) [Deutsch] Ziel: Wie weit kann unter Einsatz der rasterlosen Speicherfolienradiographie bei einer Schaedelaufnahme die Strahlendosis im Vergleich zum Film-Folien-System (FFS) mit Rasterkassette (RK) fragestellungsbezogen gesenkt werden? Material und Methode: Ein Schaedelphantom (3M) wurde konventionell

  18. Improving screen-film chest radiography

    International Nuclear Information System (INIS)

    Shaikh, N.; Baker, R.A.

    1996-01-01

    Traditionally symmetric screens and double emulsion symmetric films with medium to wide latitutde are used for radiography of the chest. Beacuse of mismatch of transmitted exposure through the chest with limited latitude of the film, most of the dense areas of the chest are underexposed. Kodak's recent innovation of a unique asymmetry screen-film system (InSight) alleviates this problem. Our phantom measurement indicates that the InSight system offers wider recording range, and the flexible grid permits more positional latitude than conventional grids. Our five-year extensive clinical experience indicates that dense anatomic structures, such as mediastinum, retrocardiac and subdiaphragmatic, are more visible in the InSight system than in the conventional symmetric system. Similarly, a substantial improvement in image quality in portable chest imaging is realized by use of flexible grids because of scatter rejection and invisible grid lines. (author)

  19. Film-screen digital radiography

    International Nuclear Information System (INIS)

    Schwenker, R.P.; Eger, H.

    1985-01-01

    The excellent performance of the digital film-screen system as a receptor for projection radiographic data is discussed. An experimental system for obtaining high quality digital radiographic data by laser scanning radiographic films is described. This system is being used to evaluate the clinical utility of various digital image processing algorithms. Future plans include an investigation of quantitative analysis of projection radiographic data. Digital data obtained by film scanning can be used with digital image archiving and communications systems. (author)

  20. X-ray exposures given with various combinations of film and screen

    International Nuclear Information System (INIS)

    Schlenker, R.A.; Kirsh, I.E.

    A comparison of entrance exposure doses of patients for various film and screen combinations and xeroradiographs showed that moderate speed screen and film gave exposures 4 to 7 times greater than fast film and screen and that xeroradiographs produced exposures 20 to 40 times greater than fast film and screen. Xeroradiographs produced table top incident exposures which exceeded Illinois Department of Health limits, while conventional film-screen combinations did not. (U.S.)

  1. Tests with films and film-screens using grid-mammography

    International Nuclear Information System (INIS)

    Wolf, G.; Kallinger, G.

    1982-01-01

    A comparison was made between mammography using grid-technique with a film-screen-system and mammography without grid, and with film-screens and also using industrial films. The image-quality of grid mammography looks like the same than using conventional techniques and industrial films. The problem of soft tissue grid techniques lies in the dose requirements, which was more than using film-screen-techniques without grid. New and improved recording systems, which reduce radiation dose when using the grid technique were analyzed. (orig.) [de

  2. Are digital images good enough? A comparative study of conventional film-screen vs digital radiographs on printed images of total hip replacement

    International Nuclear Information System (INIS)

    Eklund, K.; Jonsson, K.; Lindblom, G.; Lundin, B.; Sanfridsson, J.; Sloth, M.; Sivberg, B.

    2004-01-01

    The aim of this study was to evaluate the inter- and intra-observer variability and to find differences in diagnostic safety between digital and analog technique in diagnostic zones around hip prostheses. In 80 patients who had had a total hip replacement (THR) for more than 2 years, a conventional image and a digital image were taken. Gruen's model of seven distinct regions of interest was used for evaluations. Five experienced radiologists observed the seven regions and noted in a protocol the following distances: stem-cement; cement-bone; and stem-bone. All images were printed on hard copies and were read twice. Weighted kappa, κ w , analyses were used. The two most frequently loosening regions, stem-cement region 1 and cement-bone region 7, were closely analyzed. In region 1 the five observers had an agreement of 86.75-97.92% between analog and digital images in stem-cement, which is a varied κ w 0.29-0.71. For cement-bone region 7 an agreement of 87.21-90.45% was found, which is a varied κ w of 0.48-0.58. All the kappa values differ significantly from nil. The result shows that digital technique is as good as analog radiographs for diagnosing possible loosening of hip prostheses. (orig.)

  3. Are digital images good enough? A comparative study of conventional film-screen vs digital radiographs on printed images of total hip replacement

    Energy Technology Data Exchange (ETDEWEB)

    Eklund, K.; Jonsson, K.; Lindblom, G.; Lundin, B.; Sanfridsson, J.; Sloth, M. [Department of Radiology, Center for Medical Imaging and Physiology, Lund University Hospital, 22185, Lund (Sweden); Sivberg, B. [Department of Nursing, Faculty of Medicine, Lund University, P.O. Box 157, 22100, Lund (Sweden)

    2004-05-01

    The aim of this study was to evaluate the inter- and intra-observer variability and to find differences in diagnostic safety between digital and analog technique in diagnostic zones around hip prostheses. In 80 patients who had had a total hip replacement (THR) for more than 2 years, a conventional image and a digital image were taken. Gruen's model of seven distinct regions of interest was used for evaluations. Five experienced radiologists observed the seven regions and noted in a protocol the following distances: stem-cement; cement-bone; and stem-bone. All images were printed on hard copies and were read twice. Weighted kappa, {kappa}{sub w}, analyses were used. The two most frequently loosening regions, stem-cement region 1 and cement-bone region 7, were closely analyzed. In region 1 the five observers had an agreement of 86.75-97.92% between analog and digital images in stem-cement, which is a varied {kappa}{sub w} 0.29-0.71. For cement-bone region 7 an agreement of 87.21-90.45% was found, which is a varied {kappa}{sub w} of 0.48-0.58. All the kappa values differ significantly from nil. The result shows that digital technique is as good as analog radiographs for diagnosing possible loosening of hip prostheses. (orig.)

  4. High intensification screen-film systems in thorax radiography: a clinical comparison

    International Nuclear Information System (INIS)

    Schaefer, C.B.; Sokiranski, R.; Claussen, C.D.

    1995-01-01

    Objective: The quality of chest images was evaluated for a conventional screen-film system, a new asymmetric screen-film system, and a new uv screen-film system. Materials and Methods: 138 Chest radiographs (69 p.a., 69 lateral) obtained with three different high intensification screen-film combinations were compared. Film density and film contrast were measured. Three readers graded the image quality according to 16 criteria. Results: The asymmetric film-screen combination Insight HC showed the lowest film contrast, the best exposure range, and a elevated film density in the mediastinal area. The asymmetric screen-film system was ranked by all three observers as being substantially better in image quality. Conclusion: Compared to conventional screen-film systems, the new screen-film systems can improve the image quality of chest radiographs. Therefore, the new high intensification screen-film combinations can be used as a low cost alternative to the Amber technique and digital radiography. (orig.) [de

  5. Screen printed thick film based pMUT arrays

    DEFF Research Database (Denmark)

    Hedegaard, Tobias; Pedersen, T; Thomsen, Erik Vilain

    2008-01-01

    This article reports on the fabrication and characterization of lambda-pitched piezoelectric micromachined ultrasound transducer (pMUT) arrays fabricated using a unique process combining conventional silicon technology and low cost screen printing of thick film PZT. The pMUTs are designed as 8...

  6. The relative and absolute speed of radiographic screen - film systems

    International Nuclear Information System (INIS)

    Lee, In Ja; Huh, Joon

    1993-01-01

    Recently, a large number of new screen-film systems have become available for use in diagnostic radiology. These new screens are made of materials generally known as rare - earth phosphors which have high x-ray absorption and high x-ray to light conversion efficiency compared to calcium tungstate phosphors. The major advantage of these new systems is reduction of patient exposure due to their high speed or high sensitivity. However, a system with excessively high speed can result in a significant degradation of radiographic image quality. Therefore, the speed is important parameters for users of these system. Our aim of in this was to determine accurately and precisely the absolute speed and relative speeds of both new and conventional screen - film system. We determined the absolute speed in condition of BRH phantom beam quality and the relative speed were measured by a split - screen technique in condition of BRH and ANSI phantom beam quality. The absolute and the relative speed were determined for 8 kinds of screen - 4 kinds of film in regular system and 7 kinds pf screen - 7 kinds of film in ortho system. In this study we could know the New Rx, T - MAT G has the highest film speed, also know Green system's standard deviation of relative speed larger than blue system. It was realized that there were no relationship between the absolute speed and the blue system. It was realized that there were no relationship between the absolute speed and the relative speed in ortho or regular system

  7. Sensitivity of screen-film systems

    International Nuclear Information System (INIS)

    Sandborg, M.; Nilsson, Goergen; Holje, G.

    1992-01-01

    This report, which has been funded by SSI, presents sensitivity data on the 'second generation' of modern intensifying screens, commercially available at the onset of the investigation. The sensitivity of the screen-film systems was evaluated with 80 kV tube potential and a total filtration of 3.0 mm Al. 20 mm aluminum was used for simulating human tissue, since it gives the same HVL x , as does 25 cm water. Kerma in air, needed to produce a net film density of 1.00 was determined and its inverse, expressed in mGy -1 , was taken as an indicator of the sensitivity; here called the sensitivity class of a screen-film system

  8. PAPNET-assisted primary screening of conventional cervical smears.

    Science.gov (United States)

    Cenci, M; Nagar, C; Vecchione, A

    2000-01-01

    The PAPNET System is the only device with a neural-network-based-artificial intelligence to detect and show the images of abnormal cells on the monitor to be evaluated in an interactive way. We effectively used the PAPNET in rescreening of conventional cervical smears and we detected its advantages and its disadvantages. In this paper, we report our results from PAPNET-assisted primary screening performed on 20,154 conventional smears. The smears were classified as Negative or as Review. The Negative cases were rapidly rescreened mainly near the coverslip edges, which are the slide areas not analyzed by automated devices because of focusing problems. The Review cases were fully reanalyzed by the optic microscope. In summary, 140 positive smears were detected: 57 cases showed changes due to HPV, 63 LSIL, 15 HSIL, and 5 carcinomas. Therefore, the PAPNET System was confirmed as useful in primary screening of conventional cervical samples as well as rescreening.

  9. Factors related to screen-film contact in industrial radiography

    International Nuclear Information System (INIS)

    Talpe, P.

    1985-01-01

    The relative importance of screen-film contact for industrial radiography is discussed, and the results are presented of an extensive field devaluation of a new type of vacuum prepacked film-screen combination

  10. Eye dose measurements using conventional and rare-earth screens during tomography of the para-nasal sinuses

    International Nuclear Information System (INIS)

    Eddleston, B.; Moores, B.M.; Walker, A.

    1977-01-01

    Eye dose measurements have been performed when using medium speed conventional and rare-earth screen-film combinations during tomography of the para-nasal sinuses. The measurements showed that using conventional intensifying screens with the A.P. view a total eye dose of about 20 rad may be given during an examination. This eye dose can be reduced by 98% using the P.A. position. If rare-earth screen/film combinations were employed the eye dose measured in the A.P. view was reduced by 75% of that obtained with conventional screens without detectable loss of image quality. A total eye dose reduction of about 99.5% was measured in the P.A. view with the rare-earth systems. (author)

  11. Screen-film specimen radiography

    International Nuclear Information System (INIS)

    Shepard, S.J.; Hogan, J.; Schreck, B.

    1990-01-01

    This paper reports on the reproducibility and quality of biopsy specimen radiographs, a unique phototimed cabinet x-ray system is being developed. The system utilizes specially modified Kodal Min-R cassettes and will be compatible with current mammographic films. Tube voltages are in the 14-20-kVp range with 0.1-1.0-second exposure times. A top-hat type compression device is used (1) to compress the specimen to uniform thickness, (2) to measure the specimen thickness and determine optimum kVp, and (3) to superimpose a grid over the specimen for identification of objects of radiographic interest. The phototiming circuit developed specifically for this purpose will be described along with the modified Min-R cassette. Characteristics of the generator and cabinet will also be described. Tests will be performed on phantoms to evaluate the system limitations

  12. A clinical trial of a rare earth screen/film system in a periapical cassette

    International Nuclear Information System (INIS)

    Kogon, S.L.; Stephens, R.G.; Reid, J.A.; Lubus, N.J.

    1984-01-01

    In a clinical trial, a slow rare earth screen/film system (Siemens Titan 2D/Kodak XG) was used to obtain intraoral radiographs at conventional monitoring stages in endodontic treatment. The screen film image proved to be an effective substitute for the direct-exposure Ultraspeed periapical film. The intraoral cassettes, designed and fabricated for the study, were an adaptation of the flexible, vacuum-sealed cassettes used in mammography. It is believed that when a practicable periapical cassette is manufactured, many additional indications for the system are probable. Major reductions in patient exposure of at least 85% to 90% per periapical film would be effected

  13. Proximal surface caries detection with direct-exposure and rare earth screen/film imaging

    International Nuclear Information System (INIS)

    Lundeen, R.C.; McDavid, W.D.; Barnwell, G.M.

    1988-01-01

    This laboratory study compared five imaging systems for their diagnostic accuracy in detection of proximal surface dental caries. Ten viewers provided data on radiographic detectability of carious lesions. The diagnostic accuracy of each system was determined with receiver operating characteristic (ROC) curves by comparing viewer data with the true state of the teeth as determined microscopically. D-speed film marginally outperformed the other four systems, but the three screen/film systems matched the diagnostic accuracy of E-speed film. Radiation reductions between 62% and 92% were achieved with the screen/film systems when compared to the two conventional dental films. The feasibility of designing a screen/film bite-wing cassette was shown, but the poor diagnostic accuracy of the present bite-wing system indicated a need for a new technology in caries detection

  14. Optimization of patient protection using rare earth screen in conventional imaging procedure

    International Nuclear Information System (INIS)

    Inkoom, S.; Schandorf, C.; Fletcher, J.J.

    2008-01-01

    The purpose of this study was to optimize patient protection using rare earth screen of speed 400 in place of conventional screen-film of speed 200. The entrance surface dose (ESD) for the two screen-film systems was determined for patients undergoing simple radiographic examinations (chest, lumbar spine and pelvis series). The determination of the ESD included backscatter factors. The ESD was the optimizing parameter and its trade off with the image quality assessment, which was surveyed based on the information obtained through standardized questionnaire. The estimated ESDs were compared with reference levels set by the Community of European Commission (CEC) for a standard adult patient. For chest PA, ESD estimates were lower than the CEC reference levels whilst that of lumbar spine AP and LAT and pelvis AP were high. Upon the adoption of rare earth screen of speed 400, a dose reduction of 33% for chest, 17% for lumbar spine and 28% for pelvis examinations was achieved. From the observations made from this study, some corrective actions such as equipment quality control of parameters that affect patient dose and image quality like kVp accuracy and consistency, mAs accuracy and consistency, optimal film processing conditions, regular film reject analysis to detect and minimize the root causes and contributory factors to poor image quality and periodic training of staff on dose reduction techniques must be undertaken. Regular assessment of patient dose and image quality, equipment quality control, adoption of faster rare earth screens and optimum radiographic technique are therefore recommended in order to achieve optimization goals. (author)

  15. Latent fingerprints on different type of screen protective films

    Directory of Open Access Journals (Sweden)

    Yuttana Sudjaroen

    2016-07-01

    Full Text Available The purpose of this research was to study the quality of latent fingerprint on different types of screen protective films including screen protector, matte screen protector, anti-fingerprint clear screen protector and anti-fingerprint matte screen protector by using black powder method in developing latent fingerprints. The fingerprints were performed by 10 volunteers whose fingers (right index, right thumb, left index and left thumb were stubbing at different types of screen protective films and subsequently latent fingerprints were developed by brushing with black powder. Automated Fingerprint Identification System (AFIS counted the numbers of minutiae points from 320 latent fingerprints. Anti-fingerprint matte screen protective film produced the best quality of latent fingerprint with an average minutiae point 72.65, followed by matte screen protective film, clear screen protective film and anti-fingerprint clear screen protective film with an average minutiae point of 155.2, 135.0 and 72.65 respectively. The quality of latent fingerprints developed between a clear and a matte surface of screen protective films showed a significant difference (sig>0.05, whereas the coat and the non-coat with anti-fingerprint chemical revealed a non-significant difference (sig<0.05 in their number of minutiae points.

  16. Epitaxial patterning of thin-films: conventional lithographies and beyond

    International Nuclear Information System (INIS)

    Zhang, Wei; Krishnan, Kannan M

    2014-01-01

    Thin-film based novel magnetic and electronic devices have entered a new era in which the film crystallography, structural coherence, and epitaxy play important roles in determining their functional properties. The capabilities of controlling such structural and functional properties are being continuously developed by various physical deposition technologies. Epitaxial patterning strategies further allow the miniaturization of such novel devices, which incorporates thin-film components into nanoscale architectures while keeping their functional properties unmodified from their ideal single-crystal values. In the past decade, epitaxial patterning methods on the laboratory scale have been reported to meet distinct scientific inquires, in which the techniques and processes used differ from one to the other. In this review we summarize many of these pioneering endeavors in epitaxial patterning of thin-film devices that use both conventional and novel lithography techniques. These methods demonstrate epitaxial patterning for a broad range of materials (metals, oxides, and semiconductors) and cover common device length scales from micrometer to sub-hundred nanometer. Whilst we have been motivated by magnetic materials and devices, we present our outlook on developing systematic-strategies for epitaxial patterning of functional materials which will pave the road for the design, discovery and industrialization of next-generation advanced magnetic and electronic nano-devices. (topical review)

  17. Use of buffy coat thick films in detecting malaria parasites in patients with negative conventional thick films.

    Science.gov (United States)

    Duangdee, Chatnapa; Tangpukdee, Noppadon; Krudsood, Srivicha; Wilairatana, Polrat

    2012-04-01

    To determine the frequency of malaria parasite detection from the buffy coat blood films by using capillary tube in falciparum malaria patients with negative conventional thick films. Thirty six uncomplicated falciparum malaria patients confirmed by conventional thick and thin films were included in the study. The patients were treated with artemisinin combination therapy at Hospital for Tropical Diseases, Bangkok, Thailand for 28 day. Fingerpricks for conventional blood films were conducted every 6 hours until negative parasitemia, then daily fingerpricks for parasite checks were conducted until the patients were discharged from hospital. Blood samples were also concurrently collected in 3 heparinized capillary tubes at the same time of fingerpricks for conventional blood films when the prior parasitemia was negative on thin films and parasitemia was lower than 50 parasites/200 white blood cells by thick film. The first negative conventional thick films were compared with buffy coat thick films for parasite identification. Out of 36 patients with thick films showing negative for asexual forms of parasites, buffy coat films could detect remaining 10 patients (27.8%) with asexual forms of Plasmodium falciparum. The study shows that buffy coat thick films are useful and can detect malarial parasites in 27.8% of patients whose conventional thick films show negative parasitemia.

  18. Reader performance in detection of pneumothorax on conventional chest films versus computed radiographs

    International Nuclear Information System (INIS)

    Elam, E.A.; Hillman, B.J.; Fajardo, L.L.

    1990-01-01

    This paper evaluates the suitability of digital radiography for the detection of pneumothoraces, we compared radiologist' performance in four interpretation settings: conventional film-screen (FS) chest radiographs; small-format (8 x 6.5-inch) computed radiography (CR) (Toshiba); large-format (14 x 17-inch) CR; and CR images viewed on a digital workstation. Twenty-three frontal-view chest radiographs with pneumothoraces and 22 other chest radiographs, either normal or showing miscellaneous abnormalities, were read by six board-certified radiologist in each interpretation setting. We compared the sensitivity, specificity, and receiver operating characteristic (ROC) performances they achieved among the interpretation settings with the use of sequential paired t tests. To date, four readers have completed their reading of both the FS and the small-format CR films

  19. Evaluation of mammographic screen-film combinations in the clinic

    International Nuclear Information System (INIS)

    Shepard, J.

    1987-01-01

    Six commercially available mammographic film-screen combinations were evaluated in the authors department. Film speed and contrast was measured by obtaining H and D curves. Sensitivity to processing conditions was determined by analyzing changes in the H and D cures as a function of development time and temperature and by examining artifacts in a uniformly exposed film. Radiographs of a 0.5 0 star pattern show relative screen unsharpness. The speed of the film-screen combination is indicated by calculating patient dose necessary to produce optical densities of 1.5 through phantom thicknesses of 3.5 cm of acrylic. Images of a modified RMI detail phantom obtained with each film-screen combination were evaluated by 22 radiologist. Results indicate the physicians' overall preference

  20. A comparison of the accuracy of film-screen mammography, full-field digital mammography, and digital breast tomosynthesis

    International Nuclear Information System (INIS)

    Michell, M.J.; Iqbal, A.; Wasan, R.K.; Evans, D.R.; Peacock, C.; Lawinski, C.P.; Douiri, A.; Wilson, R.; Whelehan, P.

    2012-01-01

    Aim: To measure the change in diagnostic accuracy of conventional film-screen mammography and full-field digital mammography (FFDM) with the addition of digital breast tomosynthesis (DBT) in women recalled for assessment following routine screening. Materials and methods: Ethics approval for the study was granted. Women recalled for assessment following routine screening with screen-film mammography were invited to participate. Participants underwent bilateral, two-view FFDM and two-view DBT. Readers scored each lesion separately for probability of malignancy on screen-film mammography, FFDM, and then DBT. The scores were compared with the presence or absence of malignancy based on the final histopathology outcome. Results: Seven hundred and thirty-eight women participated (93.2% recruitment rate). Following assessment 204 (26.8%) were diagnosed as malignant (147 invasive and 57 in-situ tumours), 286 (37.68%) as benign, and 269 (35.4%) as normal. The diagnostic accuracy was evaluated by using receiving operating characteristic (ROC) and measurement of area under the curve (AUC). The AUC values demonstrated a significant (p = 0.0001) improvement in the diagnostic accuracy with the addition of DBT combined with FFDM and film-screen mammography (AUC = 0.9671) when compared to FFDM plus film-screen mammography (AUC = 0.8949) and film-screen mammography alone (AUC = 0.7882). The effect was significantly greater for soft-tissue lesions [AUC was 0.9905 with the addition of DBT and AUC was 0.9201 for FFDM with film-screen mammography combined (p = 0.0001)] compared to microcalcification [with the addition of DBT (AUC = 0.7920) and for FFDM with film-screen mammography combined (AUC = 0.7843; p = 0.3182)]. Conclusion: The addition of DBT increases the accuracy of mammography compared to FFDM and film-screen mammography combined and film-screen mammography alone in the assessment of screen-detected soft-tissue mammographic abnormalities.

  1. Quality assurance programme for screen film mammography

    International Nuclear Information System (INIS)

    2009-01-01

    The application of radiation in human health, for both the diagnosis and treatment of disease, is an important component of the work of the IAEA. In the area of diagnostic radiology, this work is focused on quality assurance methods to both the promotion of the effective use of radiation for diagnostic outcome, through achieving and maintaining appropriate image quality, and also on dose determination to allow the monitoring and reduction of dose to the patient. In response to heightened awareness of the importance of patient dose contributed by radiology procedures, the IAEA published Dosimetry in Diagnostic Radiology: An International Code of Practice (Technical Reports Series No. 457) in 2007, to form a basis for patient dose determination for the Member States. Further to this, it is recognized that for complex diagnostic procedures, such as mammography, a detailed guidance document is required to give the professionals in the clinical centre the knowledge necessary to assess the patient dose, as well as to ensure that the procedure gives the maximal patient benefit possible. It is well documented that without the implementation of a quality culture and a systematic quality assurance programme with appropriate education, the detection of breast cancer cannot be made at an early enough stage to allow effective curative treatment to be undertaken. Currently there are a number of established quality assurance protocols in mammography from national and regional institutions, however, many of these protocols are distinctive and so a harmonized approach is required. This will allow the Member States to facilitate quality assurance in mammography in a standardized way which will also facilitate the introduction of national quality assurance programmes that are needed to underpin effective population screening programmes for breast cancer. Development of a quality assurance document for screen film mammography was started in 2005 with the appointment of a drafting

  2. Value of the asymmetric film-screen system InSight HC in chest imaging

    International Nuclear Information System (INIS)

    Haeussler, M.D.; Lenzen, H.; Reckels, C.; Peters, P.E.

    1994-01-01

    The asymmetric film-screen system InSight HC represents a development to optimize chest imaging. The purpose of the study was to compare the exposure range and the image quality of this new system with a conventional film-screen system. The optical density of images in both techniques was measured and the image quality of 100 chest images from 50 intensive-care patients was evaluated. 4 observers graded the image quality of organic, non-organic and pathological structures. Statistical evaluation was performed by interobserver analysis. The asymmetric film-screen system shows a larger exposure range and a superior image quality in the mediastinal field. The image quality in the peripheral field must be judged critically and improved especially because of the poor recognizability of pneumothoraces. (orig.) [de

  3. Screen printed nanosized ZnO thick film

    Indian Academy of Sciences (India)

    Unknown

    The ex- tracted powder was screen printed on glass substrates using ethyl cellulose as binder and turpinol as solvent. ... racterized and a thick film paste is prepared by adding suitable .... UV peak and a broad green emission which is usually.

  4. Receiver operating characteristic analysis of chest radiographs with computed radiography and conventional analog films

    International Nuclear Information System (INIS)

    Morioka, C.; Brown, K.; Dalter, S.; Milos, M.J.; Huang, H.K.; Kangarloo, H.; Boechat, I.M.; Batra, P.

    1988-01-01

    Receiver operating characteristic is used to compare the image quality of films obtained digitally using computed radiography (CR) and conventionally using analog film following fluoroscopic examination. Twenty-four cases, some with a solitary noncalcified nodule and/or pneumothorax, were collected. Ten radiologists have been tested viewing analog and CR digital films separately. Preliminary results indicate that there is no significant difference in the ability to detect either a pneumothorax or a solitary noncalcified nodule when comparing CR digital film with conventional analog film. A comparison of the CR digital image displayed on a 2,048-line monitor against analog and CR digital film is in progress

  5. Screen-printed piezoceramic thick films for miniaturised devices

    DEFF Research Database (Denmark)

    Lou-Moeller, R.; Hindrichsen, Christian Carstensen; Thamdrup, Lasse Højlund

    2007-01-01

    machining. On the other hand, the process of screen printing thick films involves potential problems of thermal matching and chemical compatibility at the processing temperatures between the functional film, the substrate and the electrodes. As an example of such a miniaturised device, a MEMS accelerometer...

  6. Hydroxyapatite screen-printed thick films: optical and electrical properties

    International Nuclear Information System (INIS)

    Silva, C.C.; Rocha, H.H.B.; Freire, F.N.A.; Santos, M.R.P.; Saboia, K.D.A.; Goes, J.C.; Sombra, A.S.B.

    2005-01-01

    In this paper, we did a study on the structural and electrical properties of bioceramic hydroxiapatite (HA) thick films. The films were prepared in two layers using the screen-printing technique on Al 2 O 3 substrates. Mechanical alloying has been used successfully to produce nanocrystalline powders of hydroxyapatite to be used in the films. We also look for the effect of the grain size of the HA in the final properties of the film. The samples were studied using X-ray diffraction (XRD), scanning electron microscopy (SEM), energy-dispersive spectroscopy (EDS), infrared and Raman scattering spectroscopy and electrical measurements. We did a study of the dielectric permittivity and the loss of the films in the radio-frequency of the spectra. The X-ray diffraction patterns of the films indicate that all the peaks associated to HA phase is present in the films. One can notice that, for all the films there is a decrease of the DC (dielectric constant) with the increase of the frequency. The values of the dielectric constant of the films are in between 4 and 9 (at 1 kHz), as a function of the flux concentration. The loss is decreasing as we increase the frequency for all the films. These results strongly suggest that the screen-printing HA thick films are good candidates for applications in biocompatible coatings of implant materials

  7. Hydroxyapatite screen-printed thick films: optical and electrical properties

    Energy Technology Data Exchange (ETDEWEB)

    Silva, C.C. [Laboratorio de Telecomunicaco-tilde es e Ciencia e Engenharia de Materiais (LOCEM), Departamento de Fisica, Universidade Federal do Ceara, Campus do Pici, Caixa Postal 6030, 60455-760 Fortaleza, Ceara (Brazil); Rocha, H.H.B. [Laboratorio de Telecomunicaco-tilde es e Ciencia e Engenharia de Materiais (LOCEM), Departamento de Fisica, Universidade Federal do Ceara, Campus do Pici, Caixa Postal 6030, 60455-760 Fortaleza, Ceara (Brazil); Freire, F.N.A. [Departamento de Quimica Orga-circumflex nica e Inorga-circumflex nica-UFC, Caixa Postal 6030, CEP 60455-760, Fortaleza, Ceara (Brazil); Santos, M.R.P. [Laboratorio de Telecomunicaco-tilde es e Ciencia e Engenharia de Materiais (LOCEM), Departamento de Fisica, Universidade Federal do Ceara, Campus do Pici, Caixa Postal 6030, 60455-760 Fortaleza, Ceara (Brazil); Saboia, K.D.A. [Laboratorio de Telecomunicaco-tilde es e Ciencia e Engenharia de Materiais (LOCEM), Departamento de Fisica, Universidade Federal do Ceara, Campus do Pici, Caixa Postal 6030, 60455-760 Fortaleza, Ceara (Brazil); Goes, J.C. [Laboratorio de Telecomunicaco-tilde es e Ciencia e Engenharia de Materiais (LOCEM), Departamento de Fisica, Universidade Federal do Ceara, Campus do Pici, Caixa Postal 6030, 60455-760 Fortaleza, Ceara (Brazil); Sombra, A.S.B. [Laboratorio de Telecomunicaco-tilde es e Ciencia e Engenharia de Materiais (LOCEM), Departamento de Fisica, Universidade Federal do Ceara, Campus do Pici, Caixa Postal 6030, 60455-760 Fortaleza, Ceara (Brazil)]. E-mail: sombra@fisica.ufc.br

    2005-07-15

    In this paper, we did a study on the structural and electrical properties of bioceramic hydroxiapatite (HA) thick films. The films were prepared in two layers using the screen-printing technique on Al{sub 2}O{sub 3} substrates. Mechanical alloying has been used successfully to produce nanocrystalline powders of hydroxyapatite to be used in the films. We also look for the effect of the grain size of the HA in the final properties of the film. The samples were studied using X-ray diffraction (XRD), scanning electron microscopy (SEM), energy-dispersive spectroscopy (EDS), infrared and Raman scattering spectroscopy and electrical measurements. We did a study of the dielectric permittivity and the loss of the films in the radio-frequency of the spectra. The X-ray diffraction patterns of the films indicate that all the peaks associated to HA phase is present in the films. One can notice that, for all the films there is a decrease of the DC (dielectric constant) with the increase of the frequency. The values of the dielectric constant of the films are in between 4 and 9 (at 1 kHz), as a function of the flux concentration. The loss is decreasing as we increase the frequency for all the films. These results strongly suggest that the screen-printing HA thick films are good candidates for applications in biocompatible coatings of implant materials.

  8. A comparative study of computed radiographic cephalometry and conventional cephalometry in reliability of head film measurements

    International Nuclear Information System (INIS)

    Kim, Hyung Done; Kim, Kee Deog; Park, Chang Seo

    1997-01-01

    The purpose of this study was to compare and to find out the variability of head film measurements (landmarks identification) between Fuji computed radiographic cephalometry and conventional cephalometry. 28 Korean adults were selected. Lateral cephalometric FCR film and conventional cephalometric film of each subject was taken. Four investigators identified 24 cephalometric landmarks on lateral cephalometric FCR film and conventional cephalometric film were statistically analysed. The results were as follows : 1. In FCR film and conventional film, coefficient of variation (C.V.) of 24 landmarks was taken horizontally and vertically. 2. In comparison of significant differences of landmarks variability between FCR film and conventional film, horizontal l value of coefficient of variation showed significant differences in four landmarks among twenty-four landmarks, but vertical a value of coefficient of variation showed significant differences in sixteen landmarks among twenty-four landmarks. FCR film showed significantly less variability than conventional film in 17 subjects among 20 (4+16) subjects that sho wed significant difference.

  9. Mammographic microcalcifications: Detection with xerography, screen-film, and digitized film display

    International Nuclear Information System (INIS)

    Smathers, R.L.; Bush, E.; Drace, J.; Stevens, M.; Sommer, F.G.; Brown, B.W.; Karras, B.

    1986-01-01

    Pulverized bone specks and aluminum oxide specks were measured by hand into sizes ranging from 0.2 mm to 1.0 mm and then arranged in clusters. These clusters were superimposed on a human breast tissue phantom, and xeromammograms and screen-film mammograms of the clusters were made. The screen-film mammograms were digitized using a high-resolution laser scanner and then displayed on cathode ray tube (CRT) monitors. Six radiologists independently counted the microcalcifications on the xeromammograms, the screen-film mammograms, and the digitized film mammograms. The xeromammograms were examined with a magnifying glass; the screen-film images were examined with a magnifying glass and by hot light; and the digitized-film images were examined by electronic magnification and image processing. The bone speck size that corresponded to a mean 50% detectability level for each technique was as follows: xeromammography, 0.550 mm; digitized film, 0.573 mm; and screen-film, 0.661 mm. We postulate that electronic magnification and image processing with edge enhancement can improve the capability of screen-film mammography to enhance the detection of microcalcifications

  10. Solubility tests and the peripheral blood film method for screening ...

    African Journals Online (AJOL)

    Objective. To determine the cost benefit of screening for sicklecell disease among infants at district health centres in Uganda using sickling, solubility tests and the peripheral blood film method. Methods. Pilot screening services were established at district health centres. Cost benefit analysis (CBA) was performed in four ...

  11. Noise of screen-film systems: origins and components

    Energy Technology Data Exchange (ETDEWEB)

    Kuhn, H

    1983-01-01

    When using the more sensitive rare-earth intensifying screens in radiography applying the screen-film system, one has to cope with an increase in quantum noise. Measurement of Wiener spectra will help to determine the noise of the film. With an appropriate apparatus, the noise spectra of screen-film systems of different sensitivity have been ascertained and compared with theoretical assessments. The integral noise made up of the components film noise, screen noise and quantum noise have been thoroughly analysed. Adequate choice of radiographic conditions (such as modification of film exposure time via the screen, change of tube voltage) will affect the number of absorbed X-ray quanta in the luminous substance and thus the quantum noise which, as was found out, largely contributes to the integral noise together with another factor, graininess of the film. The study shows that although quantum noise has to be cut back, this should not be done at any price, and due regard must be paid to other factors influencing the image quality of the system, such as contrast and MTF.

  12. In vivo comparison of screen-film mammography and xeromammography

    International Nuclear Information System (INIS)

    Yagan, R.; Skubic, S.E.; Oravec, D.; Green, H.Y.

    1987-01-01

    In vivo comparison of film-screen with grid and xeromammography was performed in 97 patients by three mammographers experienced with both modalities. The results show that file-screen modality is superior to xeromammography in the following areas: (1) in identifying of microcalcifications and determining their topographic characteristics; (2) in visualizing masses; and (3) in visualizing the nipple and entire skin line without artifacts. Both methods were equal in imaging of the parenchyma of dense breasts. The chest wall is somewhat better visualized with xeromammography, without providing any clinical advantage in the cases reviewed. The authors conclude that film-screen mammography with antiscatter grid is the preferred method in breast evaluation

  13. Technical and clinical evaluation of an improved-contrast screen-film combination for radiation therapy portal localization imaging

    International Nuclear Information System (INIS)

    Haus, Arthur G.; Dickerson, Robert E.; Huff, Kenneth E.; Monte, Suzanne; Schlager, Barbara A.; Atanas, Meri; Matloubieh, Ahmad

    1996-01-01

    Purpose/Objective: A problem with conventional radiation therapy portal images is low image contrast, due in part to the low attenuation of the exposing radiation by the anatomical parts being imaged and the contrast capabilities of the film or screen-film combination. The purpose of this study was to design, develop and clinically evaluate a new screen-film combination for portal localization imaging which provides significantly higher contrast and therefore improved image quality. Materials and Methods: Comparison phantom and clinical images were made at two radiation oncology facilities with the new prototype screen-film combination and a commercial screen-film combination currently used for portal localization imaging. All images were made with linear accelerators at 6MV. Sensitometric data was also obtained. The prototype combination features a 1.0mm copper front screen plus front and back gadolinium oxysulfide fluorescent intensifying screens and a very-slow-speed film having inherently high contrast. The film emulsion layers are coated on a 7 mil Estar base which allows processing in a conventional rapid process film processor. For this combination, the film is exposed primarily by light from the intensifying screens. The current, commercially available screen-film combination was a Kodak X-Omatic L Radiation Therapy Cassette with a 1.0mm copper front screen and a 0.25mm lead back screen and Kodak X-Omat RP film in ready pack envelope. With this combination, the film emulsion is exposed by electrons generated in the metal screens. All films were processed in a Kodak M35A X-Omat processor. Radiation oncologists reviewed the phantom and clinical images. Results: Sensitometric data indicate that the film contrast (average gradient) of the new prototype combination is approximately 4 times higher than the conventional commercially available combination. Phantom and clinical comparisons at St. Mary Cancer Center, Langhorne PA. and the Daisy Marquis Jones

  14. Realization of superconductive films by screen printing

    International Nuclear Information System (INIS)

    Baudry, H.

    1988-01-01

    Screen printing is a promising method to manufacture superconductive lines making use of superconductive ceramics. An ink has been realized with YBa 2 Cu 3 0 7-x' and the process conditions defined by thermal analysis. A superconductive transition is observed after screen printing on MgO. The firing of the layer is made at 920 0 C followed by a reoxidation step at 420 0 C. The silver electrical contacts are also screen printed [fr

  15. Barium titanate thick films prepared by screen printing technique

    Directory of Open Access Journals (Sweden)

    Mirjana M. Vijatović

    2010-06-01

    Full Text Available The barium titanate (BaTiO3 thick films were prepared by screen printing technique using powders obtained by soft chemical route, modified Pechini process. Three different barium titanate powders were prepared: i pure, ii doped with lanthanum and iii doped with antimony. Pastes for screen printing were prepared using previously obtained powders. The thick films were deposited onto Al2O3 substrates and fired at 850°C together with electrode material (silver/palladium in the moving belt furnace in the air atmosphere. Measurements of thickness and roughness of barium titanate thick films were performed. The electrical properties of thick films such as dielectric constant, dielectric losses, Curie temperature, hysteresis loop were reported. The influence of different factors on electrical properties values was analyzed.

  16. An evaluation of four rare-earth film-screen combinations

    International Nuclear Information System (INIS)

    Nettle, J.R.L.; Ritchings, R.T.

    1980-01-01

    Objective and subjective assessments were made on four film-screen combinations at 140 kV for use on an EMI body scanner. The combinations used were: 3M XD film + Trimax Alpha 8 screens; Agfa Gevaert RP film + MR600 screens; Kodak Ortho G film + Lanex regular screens and Ilford type S film + rare earth rapid R screens. The objective assessment is based on the optical density of the image of a test object on a radiograph. Receiver operating characteristic techniques are used in the subjective assessment. The best results in each assessment were obtained using the Kodak Ortho G film + Lanex regular screens. (author)

  17. Comparison of first-tier cell-free DNA screening for common aneuploidies with conventional publically funded screening.

    Science.gov (United States)

    Langlois, Sylvie; Johnson, JoAnn; Audibert, François; Gekas, Jean; Forest, Jean-Claude; Caron, André; Harrington, Keli; Pastuck, Melanie; Meddour, Hasna; Tétu, Amélie; Little, Julian; Rousseau, François

    2017-12-01

    This study evaluates the impact of offering cell-free DNA (cfDNA) screening as a first-tier test for trisomies 21 and 18. This is a prospective study of pregnant women undergoing conventional prenatal screening who were offered cfDNA screening in the first trimester with clinical outcomes obtained on all pregnancies. A total of 1198 pregnant women were recruited. The detection rate of trisomy 21 with standard screening was 83% with a false positive rate (FPR) of 5.5% compared with 100% detection and 0% FPR for cfDNA screening. The FPR of cfDNA screening for trisomies 18 and 13 was 0.09% for each. Two percent of women underwent an invasive diagnostic procedure based on screening or ultrasound findings; without the cfDNA screening, it could have been as high as 6.8%. Amongst the 640 women with negative cfDNA results and a nuchal translucency (NT) ultrasound, only 3 had an NT greater or equal to 3.5 mm: one had a normal outcome and two lost their pregnancy before 20 weeks. cfDNA screening has the potential to be a highly effective first-tier screening approach leading to a significant reduction of invasive diagnostic procedures. For women with a negative cfDNA screening result, NT measurement has limited clinical utility. © 2017 John Wiley & Sons, Ltd.

  18. An alternative green screen keying method for film visual effects

    OpenAIRE

    Zhi, Jin

    2015-01-01

    This study focuses on a green screen keying method developed especially for film visual effects. There are a series of ways of using existing tools for creating mattes from green or blue screen plates. However, it is still a time-consuming process, and the results vary especially when it comes to retaining tiny details, such as hair and fur. This paper introduces an alternative concept and method for retaining edge details of characters on a green screen plate, also, a number of connected mat...

  19. Triaxial MEMS accelerometer with screen printed PZT thick film

    DEFF Research Database (Denmark)

    Hindrichsen, Christian Carstensen; Almind, Ninia Sejersen; Brodersen, Simon Hedegaard

    2010-01-01

    . In this work integration of a screen printed piezoelectric PZT thick film with silicon MEMS technology is shown. A high bandwidth triaxial accelerometer has been designed, fabricated and characterized. The voltage sensitivity is 0.31 mV/g in the vertical direction, 0.062 mV/g in the horizontal direction...

  20. MEMS Accelerometer with Screen Printed Piezoelectric Thick Film

    DEFF Research Database (Denmark)

    Hindrichsen, Christian Carstensen; Lau-Moeller, R.; Bove, T.

    2006-01-01

    A bulk-micromachined piezoelectric MEMS accelerometer with screen printed piezoelectric Pb(ZrxTil )O3(PZT) thick film (TF) as the sensing material has been fabricated and characterized. The accelerometer has a four beam structure with a central seismic mass (3600x3600x500 pm3) and a total chip size...

  1. MOCVD ZnO/Screen Printed Ag Back Reflector for Flexible Thin Film Silicon Solar Cell Application

    Directory of Open Access Journals (Sweden)

    Amornrat Limmanee

    2014-01-01

    Full Text Available We have prepared Ag back electrode by screen printing technique and developed MOCVD ZnO/screen printed Ag back reflector for flexible thin film silicon solar cell application. A discontinuity and poor contact interface between the MOCVD ZnO and screen printed Ag layers caused poor open circuit voltage (Voc and low fill factor (FF; however, an insertion of a thin sputtered ZnO layer at the interface could solve this problem. The n type hydrogenated amorphous silicon (a-Si:H film is preferable for the deposition on the surface of MOCVD ZnO film rather than the microcrystalline film due to its less sensitivity to textured surface, and this allowed an improvement in the FF. The n-i-p flexible amorphous silicon solar cell using the MOCVD ZnO/screen printed Ag back reflector showed an initial efficiency of 6.2% with Voc=0.86 V, Jsc=12.4 mA/cm2, and FF = 0.58 (1 cm2. The identical quantum efficiency and comparable performance to the cells using conventional sputtered Ag back electrode have verified the potential of the MOCVD ZnO/screen printed Ag back reflector and possible opportunity to use the screen printed Ag thick film for flexible thin film silicon solar cells.

  2. Vortex variable range hopping in a conventional superconducting film

    Science.gov (United States)

    Percher, Ilana M.; Volotsenko, Irina; Frydman, Aviad; Shklovskii, Boris I.; Goldman, Allen M.

    2017-12-01

    The behavior of a disordered amorphous thin film of superconducting indium oxide has been studied as a function of temperature and magnetic field applied perpendicular to its plane. A superconductor-insulator transition has been observed, though the isotherms do not cross at a single point. The curves of resistance versus temperature on the putative superconducting side of this transition, where the resistance decreases with decreasing temperature, obey two-dimensional Mott variable-range hopping of vortices over wide ranges of temperature and resistance. To estimate the parameters of hopping, the film is modeled as a granular system and the hopping of vortices is treated in a manner analogous to hopping of charges. The reason the long-range interaction between vortices over the range of magnetic fields investigated does not lead to a stronger variation of resistance with temperature than that of two-dimensional Mott variable-range hopping remains unresolved.

  3. Screens

    OpenAIRE

    2016-01-01

    This Sixth volume in the series The Key Debates. Mutations and Appropriations in European Film Studies investigates the question of screens in the context both of the dematerialization due to digitalization and the multiplication of media screens. Scholars offer various infomations and theories of topics such as the archeology of screen, film and media theories, contemporary art, pragmatics of new ways of screening (from home video to street screening).

  4. Quality study of portal images acquired by computed radiography and screen-film system under megavoltage ray

    International Nuclear Information System (INIS)

    Cao Guoquan; Jin Xiance; Wu Shixiu; Xie Congying; Zhang Li; Yu Jianyi; Li Yueqing

    2007-01-01

    Objective: To evaluate the quality of the portal images acquired by computed radiography (CR) system and conventional screen-film system, respectively. Methods: Imaging plates (IP) and X-ray films ora home-devised lead phantom with a leakage of 6.45% were acquired, and modulation transfer function (MTF) curves of the both images were measured using edge method. Portal images of 40 nasopharyngeal cancer patients were acquired by IP and screen-film system respectively. Two doctors with similar experience evaluated the damage degree of petrosal bone, the receiver operating characteristic (ROC) curve of CR images and general images were drawn according to two doctors evaluation results. Results: The identification frequency of CR system and screen-film system were 1.159 and 0.806 Lp/mm respectively. For doctor one, the area under ROC curve of CR images and general images were 0.802 and 0.742 respectively. For doctor two, the area under ROC curve of CR images and general images were 0.751 and 0.600 respectively. The MTF curve and ROC curve of CR are both better than those of screen-film system. Conclusion: The image quality of CR portal imaging is much better than that of screen-film system. The utility of CR in linear accelerator for portal imaging is promising in clinic. (authors)

  5. Speed and speed classes of film-screen systems

    International Nuclear Information System (INIS)

    Borcke, E.

    1989-01-01

    In order to carry out the DIN 6868, Part 50 (1988) acceptance test within the framework of measures of quality assurance, the dose of the film-screen combination used is needed in the plane of the cassette. Recent methods for determination of sensitivity use the film-screen system instead of artificial light and decisions can be made as to the dose of the cassette plane. In order to characterize the sensitivity, it is proposed to use a given scale of numbers for the sensitivity S in increments of Δ log S = 0.05 in numerical values. It will also be useful for practical purposes to employ the ''sensitivity class'' with 2-fold increments in order to bring the planned radiological specifications into agreement with the demands of the user. (author)

  6. Speed and speed classes of film-screen systems

    International Nuclear Information System (INIS)

    Borcke, E.

    1989-01-01

    In order to carry out the DIN 6868, Part 50(1988) acceptance test within the framework of measures of quality assurance, the dose of the film-screen combination used is needed in the plane of the cassette. Recent methods for determination of sensitivity use the film-screen system instead of artificial light and decisions can be made as to the dose of the cassette plane. In order to characterize the sensitivity, it is proposed to use a given scale of numbers for the sensitivity S in increments of Δ log S = 0.05 in numerical values. It will also be useful for practical purposes to employ the ''sensitivity class'' with 2-fold increments in order to bring the planned radiological specifications into agreement with the demands of the user. (author)

  7. Treatment verification system in radiotherapy using a digital portal imaging device. Comparison with screen/film systems

    International Nuclear Information System (INIS)

    Nakata, Manabu; Komai, Yoshinori; Okada, Takashi; Fukumoto, Satoshi; Chadani, Kazuma; Nohara, Hiroki; Kazusa, Chudou.

    1994-01-01

    A digital portal imaging (DPI) system for megavoltage photon beams was installed recently in our department. The purpose of this study is to evaluate the image quality of this system. We have analyzed the following properties of the system; relationship between measured dose-rate and pixel values of the DPI, spatial resolution, detectability of low-contrast objects and setup errors. The results were compared with those of conventional screen-film systems. As a result, the relationship between the measured dose-rate and the pixel value of the DPI was found to be linear in the dose-rate range between 100 and 400 cGy/min. Spatial resolution was 1.25 and 0.5 mm for the DPI and the screen-film systems, respectively. The slope of the contrast-detail curves differed between the DPI and the screen-film systems, the contrast thresholds were 0.6 and 0.3% for the DPI and the screen-film systems, respectively. The detectability of a setup error of 1 mm and 2 mm for the DPI was lower than that by the screen-film systems, although the difference was not very significant. In conclusion, the image quality of the DPI at present time is slightly inferior to the conventional screen-film systems. However, notable advantages of the DPI system are that any positional changes in patients during irradiation can be detected very quickly, and that quantitative analysis of the setup variation can be obtained. The image quality of the DPI will be improved as the technology regarding advances. Therefore, this verification system using the DPI device, is expected to be used for clinical radiation therapy in the future. (author)

  8. [Comparison of film-screen combination in a contrast detail diagram and with interactive image analysis. 1: Contrast detail diagram].

    Science.gov (United States)

    Hagemann, G; Eichbaum, G

    1997-07-01

    The following three film-screen combinations were compared: a) a combination of anticrossover film and UV-light emitting screens, b) a combination of blue-light emitting screens and film, and c) a conventional green fluorescing screen film combination. Radiographs of a specially designed plexiglass phantom (0.2 x 0.2 x 0.12 m3) were obtained that contained bar patterns of lead and plaster (calcium sulfate) to test high and intermediate contrast resolution and bar patterns of air to test low contrast resolution, respectively. An aluminum step wedge was integrated to evaluate dose-density curves of the radiographs. The dose values for the various step thicknesses were measured as percentage of the dose value in air for 60, 81, and 117 kV. Exposure conditions were the following: 12 pulse generator, 0.6 mm focus size, 4.7 mm aluminum prefilter, a grid with 40 lines/cm (12:1), and a focus-detector distance of 1.15 m. The thresholds of visible bars of the various pattern materials were assessed by seven radiologists, one technician, and the authors. The resulting contrast detail diagram could not prove any significant differences between the three tested screen film combinations. The pairwise comparison, however, found 8 of the 18 paired differences to be statistically significant between the conventional and the two new screen-film combinations. The authors concluded that subjective visual assessment of the threshold in a contrast detail study alone is of only limited value to grade image quality if no well-defined criteria are used (BIR report 20 [1989] 137-139). The statistical approach of paired differences of the estimated means appeared to be more appropriate.

  9. The research on noise equivalent quanta and detective quantum efficiency of screen-film system

    International Nuclear Information System (INIS)

    Xie Jingdong; Wang Changyuan; Yuan Yude; Zhang Menglong; Wang Jian; Zheng Hao; Sun Yong

    2002-01-01

    Objective: To examine the noise equivalent quanta (NEQ) and detective quantum efficiency (DQE) of screen-film system. Methods: Green 400 screen-Kodak film and CaWO 4 screen-Fuji film were used in the study. The characteristic curves were obtained by distance method. The square wave technique was employed to determine the modulation transfer function (MTF). The Wiener spectrum (WS) was determined by Fourier analysis on uniformly exposed films. The NEQ and DQE were calculated from the characteristic curve slope, MTF, and WS measurements. Results: (1) The NEQ value of Green 400 screen-Kodak film system was 1.48 x 10 6 mm -2 when the spatial frequency was 0.6 cycles/mm, and it was 0.65 times larger than that of CaWO 4 screen-Fuji film system; The NEQ value of Green 400 screen-Kodak film system was 0.329 x 10 4 mm -2 when the spatial frequency was 4.0 cycles/mm, and it was 1.55 times larger than that of CaWO 4 screen-Fuji film system. (2) The DQE value of Green 400 screen-Kodak film system was 0.224 when the spatial frequency was 0.6 cycles/mm, and it was 1.6 times larger than that of CaWO 4 screen-Fuji film system; The DQE value of Green 400 screen-Kodak film system was 0.052 when the spatial frequency was 4.0 cycles/mm, and it was 3.7 times larger than that of CaWO 4 screen-Fuji film system. Conclusion: The Green 400 Screen-Kodak film system has superior NEQ when the spatial frequency was more than 3.0 cycles/mm and has superior DQE among the total spatial frequency in comparison with CaWO 4 screen-Fuji film system

  10. A comparison of digital and screen-film mammography using quality control phantoms

    International Nuclear Information System (INIS)

    Undrill, Peter E.; O'Kane, Arlene D.; Gilbert, Fiona J.

    2000-01-01

    AIM: To compare the performance of a direct digital mammography system with normal-view and magnified-view conventional screen-film methods using quality control phantoms. MATERIALS AND METHODS: Using a Siemens Mammomat [reg] 3000 and an Opdima [reg] digital spot imaging and biopsy attachment, film and direct digital images of two phantoms [DuPont and TOR (MAM)] were obtained under normal operating conditions. These were assessed by three groups of observers with differing expertise -- radiologists, radiographers and medical physicists. Each observer was asked to compare the direct digital image with films taken in standard view and magnified view, providing scores for object visibility and confidence. For the digital images, observers were allowed to vary the image presentation parameters. RESULTS: Both phantoms showed that overall the direct digital view and the magnified view film performed significantly better (P < 0.05) than standard view film. For certain small or low contrast objects the differences became very highly significant (P < 0.001). CONCLUSION: Only the TOR (MAM) phantom showed any significant difference between digital and magnified modalities, with magnified views performing better for fine, faint filaments and digital acquisition better for low contrast objects. Almost no difference existed between the three observer groups. Undrill, P.E. (2000). Clinical Radiology 53, 782-790

  11. Comparison of average glandular dose in screen-film and digital mammography using breast tissue-equivalent phantom

    International Nuclear Information System (INIS)

    Shin, Gwi Soon; Kim, Jung Min; Kim, You Hyun; Choi, Jong Hak; Kim, Chang Kyun

    2007-01-01

    In recent years, mammography system is changed rapidly from conventional screen-film system to digital system for application to screening and diagnosis. Digital mammography system provides several advantages over screen-film mammography system. According to the information provided by the manufacturer, digital mammography system offers radiation dose reduction in comparison with screen-film mammography system, because of digital detector, particularly direct digital detector has higher x-ray absorption efficiency than screen-film combination or imaging plate (IP). We measured average glandular doses (ADG) in screen-film mammography (SFM) system with slow screen-film combination, computed mammography (CM) system, indirect digital mammography (IDM) system and direct digital mammography (DDM) system using breast tissue-equivalent phantom (glandularity 30%, 50% and 70%). The results were shown as follows: AGD values for DDM system were highest than those for other systems. Although automatic exposure control (AEC) mode was selected, the curve of the AGD values against thickness or glandularity increased significantly for the SFM system with the uniform target/filter (Mo/Mo) combination. Therefore, the AGD values for the high energy examinations were highest in the SFM system, and those for the low energy examinations were highest in the DDM system. But the curve of the AGD values against thickness and glandularity increased gently for CM system with the automatic selection of the target/filter combination (from Mo/Mo to Mo/Rh or from Mo/Rh to Rh/Rh), and the AGD values were lowest. Consequently, the parameters in mammography for each exposure besides detection efficiency play an important role in order to estimate a patient radiation dose

  12. Selenium-based digital radiography of the cervical spine. Comparison with screen-film radiography for the depiction of anatomic details

    International Nuclear Information System (INIS)

    Ludwig, K.; Diederich, S.; Wormanns, D.; Link, T.M.; Lenzen, H.; Heindel, W.

    2002-01-01

    Purpose: To compare selenium-based digital radiography with conventional screen-film radiography of the cervical spine. Materials and Methods: In a prospective study X-ray images of the cervical spine were obtained in 25 patients using selenium-based digital radiography and conventional screen-film radiography. All images were clinically indicated. Selenium-based digital radiography and conventional screen-film radiography were used in a randomized order. Four radiologists independently evaluated all 50 examinations for the visibility of 76 anatomic details according to a five-level confidence scale (1=not visible, 5=very good visibility). From the evaluation of these anatomic details scores for the upper and middle cervical spine, the cervicothoracic junction and the cervical soft tissues were calculated. The scores for selenium-based digital radiography and conventional screen-film radiography were compared using Wilcoxon's signed rank test. Results: From a total of 15,200 observations (608 per patient) the following scores were calculated for selenium-based digital radiography and for screen-film radiography, respectively: Upper cervical spine 3.88 and 3.94; middle cervical spine 4.60 and 4.48; cervico-thoracic junction 3.64 and 2.62; cervical soft tissue 4.47 and 3.46. The differences between the last two scores were statistically significant (p [de

  13. Subjective image quality comparison between two digital dental radiographic systems and conventional dental film

    Directory of Open Access Journals (Sweden)

    Muhammed Ajmal

    2014-10-01

    Recommendations: Improved software and hardware for digital imaging systems are now available and these improvements may now yield images that are comparable in quality to conventional film. However, we recommend that studies still use more observers and other statistical methods to produce ideal results.

  14. Quality control: comparison of images quality with screen film system and digital mammography CR

    International Nuclear Information System (INIS)

    Alvarenga, Frederico L.; Nogueira, Maria do Socorro

    2008-01-01

    The mammography screen film system should be used as part of processing chemicals, revelation process, equipment and this system has have a progressive replacing by the digital technology Full Field Digital Mammography FFDM, Computed Radiography (CR) Mammography and hardcopy. This new acquisition process of medical images has improved radiology section; however it is necessary efficient means for evaluating of the quality parameters. It should be considered taking into account the adaptation of the existent equipment and that procedures adopted for the exam, as well the adaptation of the new mammography films, the radiologist view box constitutes a part of the quality control program. This program aims at obtaining radiography with good quality that allows obtaining more information for the diagnosis and decreases the patient dose. For evaluation the quality image, this article is focused on presenting the differences regarding the acquired images through simulator mammography radiographic PMMA (Poly methyl methacrylate) in CR Mammography system and screen film system. The tests were accomplished at the same equipment of Mammography with the Automatic Exposure Control using a tension of 28 kV for both systems. The quality tests evaluated the spatial resolution, the own structures of the phantom, artifacts, optical density and contrast with conventional and laser films by mammography system. The installation for the accomplishment of the test has a quality control program. The evaluation was based on the pattern developed by the competent organ of the State of Minas Gerais. In this study, it was verified that the suitable Phantom Mama used by the Brazilian School of Radiology for conventional mammography did not obtain satisfactory result for Spatial Resolution in the digital mammography system CR. The final aim of this work is to obtain parameters to characterize the reference phantom quality image in an objective way. These parameters will be used to compare

  15. Speeds of film-screen combinations for radiography

    International Nuclear Information System (INIS)

    Holloway, A.F.; Cheng, C.N.; Paix, D.

    1983-01-01

    Values of Esub(x), the exposure required to yield a net optical density of 1.0, were determined for 12 blue- and nine green-sensitive film types used with 11 blue- and eight green-emitting screen types respectively. The measurements were made using x-rays generated at 80 kVp and 200 mA, under conditions simulating clinical procedures. To examine reciprocity law failure many of the determinations were repeated under similar conditions but at 15 mA. The values of Esub(x) obtained at 15 mA were 6 percent to 93 percent greater than those at 200 mA

  16. Speeds of film-screen combinations for radiography.

    Science.gov (United States)

    Holloway, A F; Cheng, C N; Paix, D

    1983-12-01

    Values of Ex, the exposure required to yield a net optical density of 1.0, were determined for 12 blue- and nine green-sensitive film types used with 11 blue- and eight green-emitting screen types respectively. The measurements were made using x-rays generated at 80 kVp and 200 mA, under conditions simulating clinical procedures. To examine reciprocity law failure many of the determinations were repeated under similar conditions but at 15 mA. The values of Ex obtained at 15 mA were 6% to 93% greater than those at 200 mA.

  17. Effect of Different Tube Potential Settings on Caries Detection using PSP Plate and Conventional Film.

    Science.gov (United States)

    De Melo, Daniela Pita; Cruz, Adriana Dibo; Melo, Saulo Leonardo Sousa; De Farias, Julyanna Filgueiras GonçAlves; Haiter-Neto, Francisco; De Almeida, Solange Maria

    2015-04-01

    To compare intraoral Phosphor Stimulable Plate digital system and intraoral film using different tube settings on incipient proximal caries detection. Five blocks, with five teeth each, were radiographically examined using phosphor plates and F-speed films. The images were acquired in 07 different tube potentials from 50-80 kV. The films were digitized. Three oral radiologists scored the images for the presence of caries using a 5-point rating scale. The areas under ROC curve were calculated. The influence of tube kilovoltage was verified by ANOVA and pair wise comparisons performed using Tukey test. Mean ROC curve areas varied from 0.446-0.628 for digital images and 0.494-0.559 for conventional images. The tube setting of 70 kV presented the best result both for digital and conventional images. Considering the image type separately, 70 kV scored highest followed by 75 and 65 kV for digital images (p=0.084). For conventional image modality, even though 70 kV presented the best result, it did not differ significantly from 80 kV, not differing from 60 and 55 kV, which did not differ from 75, 65 and 50 kV (p=0.53). Phosphor plate digital images seem to be more susceptible to tube setting potential variations then digitized film images.

  18. Effect of Different Tube Potential Settings on Caries Detection using PSP Plate and Conventional Film

    Science.gov (United States)

    Cruz, Adriana Dibo; Melo, Saulo Leonardo Sousa; De Farias, Julyanna Filgueiras GonçAlves; Haiter-Neto, Francisco; De Almeida, Solange Maria

    2015-01-01

    Purpose To compare intraoral Phosphor Stimulable Plate digital system and intraoral film using different tube settings on incipient proximal caries detection. Materials and Methods Five blocks, with five teeth each, were radiographically examined using phosphor plates and F-speed films. The images were acquired in 07 different tube potentials from 50-80 kV. The films were digitized. Three oral radiologists scored the images for the presence of caries using a 5-point rating scale. The areas under ROC curve were calculated. The influence of tube kilovoltage was verified by ANOVA and pair wise comparisons performed using Tukey test. Results Mean ROC curve areas varied from 0.446-0.628 for digital images and 0.494–0.559 for conventional images. The tube setting of 70 kV presented the best result both for digital and conventional images. Considering the image type separately, 70 kV scored highest followed by 75 and 65 kV for digital images (p=0.084). For conventional image modality, even though 70 kV presented the best result, it did not differ significantly from 80 kV, not differing from 60 and 55 kV, which did not differ from 75, 65 and 50 kV (p=0.53). Conclusion Phosphor plate digital images seem to be more susceptible to tube setting potential variations then digitized film images. PMID:26023645

  19. Non-conventional screening of the Coulomb interaction in low-dimensional and finite-size systems

    NARCIS (Netherlands)

    van den Brink, J.; Sawatzky, G.A.

    2000-01-01

    We study the screening of the Coulomb interaction in non-polar systems by polarizable atoms. We show that in low dimensions and small finite-size systems this screening deviates strongly from that conventionally assumed. In fact in one dimension the short-range interaction is strongly screened and

  20. Addition of tomosynthesis to conventional digital mammography: effect on image interpretation time of screening examinations.

    Science.gov (United States)

    Dang, Pragya A; Freer, Phoebe E; Humphrey, Kathryn L; Halpern, Elkan F; Rafferty, Elizabeth A

    2014-01-01

    To determine the effect of implementing a screening tomosynthesis program on real-world clinical performance by quantifying differences between interpretation times for conventional screening mammography and combined tomosynthesis and mammography for multiple participating radiologists with a wide range of experience in a large academic center. In this HIPAA-compliant, institutional review board-approved study, 10 radiologists prospectively read images from screening digital mammography or screening combined tomosynthesis and mammography examinations for 1-hour-long uninterrupted sessions. Images from 3665 examinations (1502 combined and 2163 digital mammography) from July 2012 to January 2013 were interpreted in at least five sessions per radiologist per modality. The number of cases reported during each session was recorded for each reader. The experience level for each radiologist was also correlated to the average number of cases reported per hour. Analysis of variance was used to assess the number of studies interpreted per hour. A linear regression model was used to evaluate correlation between breast imaging experience and time taken to interpret images from both modalities. The mean number of studies interpreted in hour was 23.8 ± 0.55 (standard deviation) (range, 14.4-40.4) for combined tomosynthesis and mammography and 34.0 ± 0.55 (range, 20.4-54.3) for digital mammography alone. A mean of 10.2 fewer studies were interpreted per hour during combined tomosynthesis and mammography compared with digital mammography sessions (P tomosynthesis and mammography and 1.9 minutes ± 0.6 (range, 1.1-3.0) for digital mammography; interpretation time with combined tomosynthesis and mammography was 0.9 minute longer (47% longer) compared with digital mammography alone (P tomosynthesis and mammography examinations decreased (R(2) = 0.52, P = .03). Addition of tomosynthesis to mammography results in increased time to interpret images from screening examinations compared

  1. Can we see enough? A comparative study of film-screen vs digital radiographs in small lesions in rheumatoid arthritis

    International Nuclear Information System (INIS)

    Jagt, E.J. van der; Hofman, S.; Kraft, B.M.; Leeuwen, M.A. van

    2000-01-01

    The aim of this study was to evaluate the performance of digital radiography in the detection of early very small erosions and joint space narrowing in the hands and feet in rheumatoid arthritis. Fifty-three sets of film-screen and digital radiographs of the same hands and feet with very small and sometimes questionable lesions (possible erosions and cysts) were scored independently two times by four investigators. The percentage of lesions found in exactly the same position for each investigator was calculated. Intra-observer agreement between first and second reading in film-screen radiography was 64-76 % (mean 67 %), and in digital radiographs 60-71 % (mean 64 %). Agreement between film-screen and digital radiographs ranged from 54 to 64 % (mean 58 %) in the first reading and from 56 to 66 % (mean 62 %) in the second reading. Overall agreement between both techniques between first and second reading ranged between 62 and 73 % (mean 65 %). Digital radiography of the hands and feet can be used in patients suspected of rheumatoid arthritis and in follow-up of those patients, because small and early erosions can be seen equally well with the digital technique as compared with the conventional film-screen technique. (orig.)

  2. Screen-film versus digital radiography of sacroiliac joints: Evaluation of image quality and dose to patients

    International Nuclear Information System (INIS)

    Jablanovic, D.; Ciraj-Bjelac, O.; Damjanov, N.; Seric, S.; Radak-Perovic, M.; Arandjic, D.; Maksimovic, R.

    2013-01-01

    The purpose of this paper is to evaluate the image quality and dose to patients in the radiography of sacroiliac joints and to perform a clinical comparative study of digital and conventional screen-film radiography. Routine radiography of sacroiliac joint was performed in 60 patients using digital and screen-film radiography. The visibility of five anatomical regions and the overall image quality were rated by experienced radiologists. Patient dose assessment in terms of entrance surface air kerma (ESAK) was performed. The digital system showed slightly improved visualisation of specific anatomical structures. Overall image quality was significantly better in the digital when compared with the screen-film imaging system. The average ESAK was 2.4 mGy in screen-film and 3.6 mGy in digital radiography. The digital radiography provided equal or better visibility of anatomical details and overall image quality, but on higher dose levels. Therefore, the practice on digital systems must be optimised. (authors)

  3. Depth Profiling Analysis of Aluminum Oxidation During Film Deposition in a Conventional High Vacuum System

    Science.gov (United States)

    Kim, Jongmin; Weimer, Jeffrey J.; Zukic, Muamer; Torr, Douglas G.

    1994-01-01

    The oxidation of aluminum thin films deposited in a conventional high vacuum chamber has been investigated using x-ray photoelectron spectroscopy (XPS) and depth profiling. The state of the Al layer was preserved by coating it with a protective MgF2 layer in the deposition chamber. Oxygen concentrations in the film layers were determined as a function of sputter time (depth into the film). The results show that an oxidized layer is formed at the start of Al deposition and that a less extensively oxidized Al layer is deposited if the deposition rate is fast. The top surface of the Al layer oxidizes very quickly. This top oxidized layer may be thicker than has been previously reported by optical methods. Maximum oxygen concentrations measured by XPS at each Al interface are related to pressure to rate ratios determined during the Al layer deposition.

  4. RHEED oscillations in spinel ferrite epitaxial films grown by conventional planar magnetron sputtering

    Science.gov (United States)

    Ojima, T.; Tainosho, T.; Sharmin, S.; Yanagihara, H.

    2018-04-01

    Real-time in situ reflection high energy electron diffraction (RHEED) observations of Fe3O4, γ-Fe2O3, and (Co,Fe)3O4 films on MgO(001) substrates grown by a conventional planar magnetron sputtering was studied. The change in periodical intensity of the specular reflection spot in the RHEED images of three different spinel ferrite compounds grown by two different sputtering systems was examined. The oscillation period was found to correspond to the 1/4 unit cell of each spinel ferrite, similar to that observed in molecular beam epitaxy (MBE) and pulsed laser deposition (PLD) experiments. This suggests that the layer-by-layer growth of spinel ferrite (001) films is general in most physical vapor deposition (PVD) processes. The surfaces of the films were as flat as the surface of the substrate, consistent with the observed layer-by-layer growth process. The observed RHEED oscillation indicates that even a conventional sputtering method can be used to control film thickness during atomic layer depositions.

  5. RHEED oscillations in spinel ferrite epitaxial films grown by conventional planar magnetron sputtering

    Directory of Open Access Journals (Sweden)

    T. Ojima

    2018-04-01

    Full Text Available Real-time in situ reflection high energy electron diffraction (RHEED observations of Fe3O4, γ-Fe2O3, and (Co,Fe3O4 films on MgO(001 substrates grown by a conventional planar magnetron sputtering was studied. The change in periodical intensity of the specular reflection spot in the RHEED images of three different spinel ferrite compounds grown by two different sputtering systems was examined. The oscillation period was found to correspond to the 1/4 unit cell of each spinel ferrite, similar to that observed in molecular beam epitaxy (MBE and pulsed laser deposition (PLD experiments. This suggests that the layer-by-layer growth of spinel ferrite (001 films is general in most physical vapor deposition (PVD processes. The surfaces of the films were as flat as the surface of the substrate, consistent with the observed layer-by-layer growth process. The observed RHEED oscillation indicates that even a conventional sputtering method can be used to control film thickness during atomic layer depositions.

  6. A comparison of two different T-grain films in rare-earth screens with a standard film-screen combination for intravenous pyelography and bone examinations

    International Nuclear Information System (INIS)

    Logan, H.; Daly, L.; Masterson, J.

    1989-01-01

    T-grain film is claimed to give significantly improved image quality, allowing use of faster screens without loss of quality, thus reducing radiation dose. We tested this claim for two systems. In each case comparison was made with our usual screen-film combination, Agfa Curix RP1 film with Kodak Xomatic Regular screens (a nominally 200 speed system). The systems tested were Kodak TMatG in Kodak Lanex Medium screens (300 speed) and Agfa STG in Kodak Lanex Regular screens (400 speed). The Agfa STG-Lanex Regular system performed less well than the standard system for intravenous pyelograms (IVPs), bones and soft-tissue detail. Its speed advantage was not apparent below 70 kV. The Kodak TMatG-Lanex Medium system was better than the standard system for IVPs but not as good for bones. It gave virtually no speed advantage below 90 kV. Kodak T-grain film in a medium-speed, rare-earth screen was found to be better than the standard system for IVPs. Agfa T-grain film in a fast rare-earth screen was unsatisfactory for IVPs. Neither combination was as good as the standard system for bones. (author)

  7. Detection of flat colorectal polyps at screening CT colonography in comparison with conventional polypoid lesions

    Energy Technology Data Exchange (ETDEWEB)

    Sakamoto, Takashi; Urata, Joji [Diagnostic Imaging Center, Saiseikai Kumamoto Hospital, Kumamoto (Japan); Mitsuzaki, Katsuhiko; Matsuda, Katsuhiko; Kawakami, Megumi [Medical Examination Center, Saiseikai Kumamoto Hospital, Kumamoto (Japan); Utsunomiya, Daisuke; Yamamura, Sadahiro; Yamashita, Yasuyuki [Diagnostic Radiology, Faculty of Life Sciences, Kumamoto Univ., Kumamoto (Japan)], e-mail: utsunomi@kumamoto-u.ac.jp

    2012-09-15

    Background: Although the screening of small, flat polyps is clinically important, the role of CT colonography (CTC) screening in their detection has not been thoroughly investigated. Purpose: To evaluate the detection capability and usefulness of CTC in the screening of flat and polypoid lesions by comparing CTC with optic colonoscopy findings as the gold standard. Material and Methods: We evaluated the CTC detection capability for flat colorectal polyps with a flat surface and a height not exceeding 3 mm (n = 42) by comparing to conventional polypoid lesions (n = 418) according to the polyp diameter. Four types of reconstruction images including multiplanar reconstruction, volume rendering, virtual gross pathology, and virtual endoscopic images were used for visual analysis. We compared the abilities of the four reconstructions for polyp visualization. Results: Detection sensitivity for flat polyps was 31.3 %, 44.4 %, and 87.5 % for lesions measuring 2-3 mm, 4-5 mm, and {>=}6 mm, respectively; the corresponding sensitivity for polypoid lesions was 47.6 %, 79.0 %, and 91.7 %. The overall sensitivity for flat lesions (47.6%) was significantly lower than polypoid lesions (64.1%). Virtual endoscopic imaging showed best visualization among the four reconstructions. Colon cancers were detected in eight patients by optic colonoscopy, and CTC detected colon cancers in all eight patients. Conclusion: CTC using 64-row multidetector CT is useful for colon cancer screening to detect colorectal polyps while the detection of small, flat lesions is still challenging.

  8. Copyright for Movie Night: Film Screenings on Campus

    Directory of Open Access Journals (Sweden)

    Michaela D. Willi Hooper

    2018-02-01

    Full Text Available I undertook this paper so that I, along with other librarians and educators, could better understand how to comply with copyright law, conserve university resources, and streamline services to students regarding the procurement of public performance rights (PPR for films and other audiovisual resources. Student groups frequently screen films on campuses, and accepted legal interpretations of sections 101 and 106 of the 1976 Copyright Act indicate that a specific license should be sought for any public performance of a copyrighted audiovisual work. My review of PPR information on the public websites of the 38 members of the ORBIS-Cascade Alliance (an academic library consortium in the Northwest points to the potential for greater collaboration with student affairs professionals and other campus departments to provide more accurate and complete information about PPR and library audiovisual resources (e.g., DVDs or streaming media that have PPR attached. Campus-focused resources about PPR should include information about fair use, educational exemptions, public domain, open licenses, and library-licensed content that comes with PPR. The academic library community could undertake a project to enhance the accessibility of accurate and supportive PPR information to student groups by creating tools or best practices. This area is ripe for more current research.

  9. [High-contrast resolution of film-screen systems in oral and maxillofacial radiology].

    Science.gov (United States)

    Kaeppler, G; Reinert, S

    2007-11-01

    The aim was to determine differences in high-contrast resolution of film-screen systems used in dental panoramic and cephalometric radiography by calculating the modulation transfer function (MTF). The radiographs used to determine the MTF should be taken by the same x-ray units as those used for patient radiographs. The MTF was determined using a lead grid and according to DIN 6867-2 for 11 film-screen systems (speed 250, speed class 200 and 400) used in dental radiographic diagnostics. The optical density was measured using a microdensitometer developed by PTB. With 10% of the modulation transfer factor, newly developed film-screen systems (speed class 200 and 400) demonstrated a resolution of 4.9 to 6 line pairs per mm (panoramic radiography). In cephalometric radiography a film-screen system (speed class 400 and green-sensitive film) had a resolution of 4.2 line pairs per mm and surpassed two film-screen systems (speed class 400, resolution of 3 line pairs per mm, blue-sensitive films). The relevance of this study is underlined by the diagnostic reference doses defined in the German X-ray Ordinance (RöV) which are also intended for dentistry. Film-screen systems (speed 250, speed class 200) previously used in dental panoramic and cephalometric radiography can be replaced by newly developed film-screen systems (speed class 400). In dental radiography dose reductions are possible with film-screen systems (speed class 400) without impairing diagnostic accuracy. The introduction of newly developed film-screen systems (speed class 400) requires lower milliampere-seconds and therefore an adjustment of the x-ray units to lower milliampere settings.

  10. Non-conventional photocathodes based on Cu thin films deposited on Y substrate by sputtering

    Energy Technology Data Exchange (ETDEWEB)

    Perrone, A. [Department of Mathematics and Physics “E. De Giorgi”, University of Salento, 73100 Lecce (Italy); National Institute of Nuclear Physics and University of Salento, 73100 Lecce (Italy); D’Elia, M. [Department of Mathematics and Physics “E. De Giorgi”, University of Salento, 73100 Lecce (Italy); Gontad, F., E-mail: francisco.gontad@le.infn.it [Department of Mathematics and Physics “E. De Giorgi”, University of Salento, 73100 Lecce (Italy); National Institute of Nuclear Physics and University of Salento, 73100 Lecce (Italy); Di Giulio, M.; Maruccio, G. [Department of Mathematics and Physics “E. De Giorgi”, University of Salento, 73100 Lecce (Italy); Cola, A. [National Council Research, Institute for Microelectronics and Microsystems, 73100 Lecce (Italy); Stankova, N.E. [Institute of Electronics, Bulgarian Academy of Sciences, 1784 Sofia (Bulgaria); Kovacheva, D.G. [Institute of General and Inorganic Chemistry, Bulgarian Academy of Sciences, 1113 Sofia (Bulgaria); Broitman, E. [Department of Physics, Chemistry and Biology (IFM), Linköping University, SE-581 83 Linköping (Sweden)

    2014-07-01

    Copper (Cu) thin films were deposited on yttrium (Y) substrate by sputtering. During the deposition, a small central area of the Y substrate was shielded to avoid the film deposition and was successively used to study its photoemissive properties. This configuration has two advantages: the cathode presents (i) the quantum efficiency and the work function of Y and (ii) high electrical compatibility when inserted into the conventional radio-frequency gun built with Cu bulk. The photocathode was investigated by scanning electron microscopy to determine surface morphology. X-ray diffraction and atomic force microscopy studies were performed to compare the structure and surface properties of the deposited film. The measured electrical resistivity value of the Cu film was similar to that of high purity Cu bulk. Film to substrate adhesion was also evaluated using the Daimler–Benz Rockwell-C adhesion test method. Finally, the photoelectron performance in terms of quantum efficiency was obtained in a high vacuum photodiode cell before and after laser cleaning procedures. A comparison with the results obtained with a twin sample prepared by pulsed laser deposition is presented and discussed.

  11. Film-Screen Mammography versus digital storage plate mammography: Hard copy and monitor display of microcalcifications and focal findings - A retrospective clinical and histologic analysis

    International Nuclear Information System (INIS)

    Schulz-Wendtland, R.; Wenkel, E.; Aichinger, U.; Tartsch, M.; Kuchar, I.; Bautz, W.

    2003-01-01

    Purpose: A retrospective clinical-histological study to determine the diagnostic accuracy of mammography using conventional screen-film cassettes (hard copy), high-resolution digital phosphor storage plates (hard copy) and monitor display (soft copy) for microcalcifications and focal lesions (BI-RADS TM category 4 or 5). Materials and methods: From April to November 2001, 76 patients underwent conventional film-screen mammography and, after diagnosis and preoperative wire localization, digital mammography with the same exposure parameters. Five investigators retrospectively determined the diagnosis after the operation from randomly distributed mediolateral views (hard-copy reading) and from the monitor display (soft-copy reading). These results were correlated with the final histology. Results: The accuracy of conventional screen-film mammography, digital mammography and monitor-displayed mammography was 67%, 65% and 68% for all findings, (n = 76), 59%, 59% and 68% for microcalcifications (n = 44) and 75%, 72% and 63% for focal lesions (n = 32). The overall results showed no difference. Conclusions: Our findings indicate equivalence of conventional screen-film mammography, high-resolution digital phosphor storage plate mammography and monitor-displayed mammography. (orig.) [de

  12. Magnification mammography: a comparison of full-field digital mammography and screen-film mammography for the detection of simulated small masses and microcalcifications

    International Nuclear Information System (INIS)

    Hermann, K.P.; Obenauer, S.; Funke, M.; Grabbe, E.H.

    2002-01-01

    The objective of this study was a comparison of a full-field digital mammography (FFDM) system and a conventional screen-film mammography (SFM) system with respect to the detectability of simulated small masses and microcalcifications in the magnification mode. All images were obtained using 1.8 times magnification. The FFDM images were obtained at radiation dose levels of 1.39, 1.0, 0.7, 0.49 and 0.24 times that of the SFM images. A contrast-detail phantom was used to compare the detection of simulated lesions using a four alternative forced-choice reader study with three readers. The correct observation ratio (COR) was calculated as the fraction of correctly identified lesions to the total number of simulated lesions. Soft-copy reading was performed for all digital images. Direct magnification images acquired with the digital system showed a lower object contrast threshold than those acquired with the conventional system. For equal radiation dose, the digital system provided a significantly increased COR (0.95) compared with the screen-film system (0.82). For simulated microcalcifications, the corresponding difference was 0.90 to 0.72. The digital system allowed equal detection to screen-film at 40% of the radiation dose used for screen film. Digital magnification images are superior to screen-film magnification images for the detection of simulated small masses and microcalcifications even at a lower radiation dose. (orig.)

  13. Comparative review of computed tomography of the spinal column and conventional x-ray films

    Energy Technology Data Exchange (ETDEWEB)

    Shin, H.; Yamaura, A.; Horie, T.; Makino, H. (Chiba Univ. (Japan). School of Medicine)

    1982-04-01

    Computerized tomography (CT) of the cervical spinal column was carried out in 39 patients using a GE.CT/T or Toshiba TCT60A scanner. There were 22 cervical disk lesions, 4 spinal neoplasms, 5 narrow spinal canals with or without ossification of the posterior longitudinal ligament, 2 syringomyelias, 5 traumas, and one Arnold-Chiari malformation. In all the patients, tomography was done after conventional spinal X-ray studies. The correlation between the CT findings and conventional X-ray films revealed the excellent capability of the CT. The measurement of the midline sagittal diameter of the spinal canal in the patient with the narrowest canal in this series showed 7.4 mm when done by CT and 9.6 mm when done by the conventional plain film at the C/sub 5/ level. To ascertain the precise sagittal diameter of the cord itself, CT myelography is indispensable after the intrathecal injection of metrizamide A; metrizamide CT myelogram is useful in determining the nature of the disease, the risk of and best approach to surgery, and the evaluation after a surgical procedure. Although the range of motion of cervical joints and intervertebral foramen are visible with the conventional films, the size of the spinal tumors, the degree of bony change, and the tumor extension to the paraspinal connective tissue can be precisely demonstrated only by CT. A CT study of the spine is a simple procedure and is less likely to produce complication, even with a metrizamide CT myelogram, though there are certain limitations in the examination.

  14. Comparison of a new digital KM screen test with conventional Hess and Lees screen tests in the mapping of ocular deviations.

    Science.gov (United States)

    Thorisdottir, Rannveig Linda; Sundgren, Johanna; Sheikh, Rafi; Blohmé, Jonas; Hammar, Björn; Kjellström, Sten; Malmsjö, Malin

    2018-05-28

    To evaluate the digital KM screen computerized ocular motility test and to compare it with conventional nondigital techniques using the Hess and Lees screens. Patients with known ocular deviations and a visual acuity of at least 20/100 underwent testing using the digital KM screen and the Hess and Lees screen tests. The examination duration, the subjectively perceived difficulty, and the patient's method of choice were compared for the three tests. The accuracy of test results was compared using Bland-Altman plots between testing methods. A total of 19 patients were included. Examination with the digital KM screen test was less time-consuming than tests with the Hess and Lees screens (P digital KM screen). Patients found the test with the digital KM screen easier to perform than the Lees screen test (P = 0.009) but of similar difficulty to the Hess screen test (P = 0.203). The majority of the patients (83%) preferred the digital KM screen test to both of the other screen methods (P = 0.008). Bland-Altman plots showed that the results obtained with all three tests were similar. The digital KM screen is accurate and time saving and provides similar results to Lees and Hess screen testing. It also has the advantage of a digital data analysis and registration. Copyright © 2018 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  15. Practical determination of sensitometric properties of medical film-screen combinations

    International Nuclear Information System (INIS)

    Vassileva, J.; Ibrachim, K.

    2000-01-01

    The aim of the study is to to compare different sensitometric techniques for medical film-screen systems and to chose the optimal one for practical use in a clinical environment and to compare the sensitometric properties of different film-screen combinations practically used for chest radiography. The measurement have been performed using TUR D800-3 radiographic installation with twelve-pulse generator and DRX 124/30/60 oDw tube. The following screens and cassettes have been investigated: VARIMEX (Poland) with PERLUX screens (Germany); DuPomt cassette with QFD screens; Kodak X-Omatic LW cassette with Lanex Regular screens. They have been combined with 4 types of films: Sterling Cronex4 (blue); Agfa CP-BU New (blue); Agfa CP-G Plus (ortho) and Kodak TMG-RA (ortho). All cassettes have been examined for light tightness and screen-film contact and all film types have been checked for the compatibility with the safe lights in the darkroom. To simulate a patient for a chest radiography standard LucAl chest phantom has been designed. The measurements show that: 1) Sensitivity of Kodak cassette with green emitting rare-earth Kodak Lanex Regular screens combined with ortho Kodak film is highest; 2) From two emitting screens - PERLUX and QFD. both combined with blue sensitive films, QFD is 3.6 times more sensitive. 3) Films Agfa CP-BU New and Cronex 4 are of the same sensitivity class but the first has higher contrast. 4) The use of ortho-chromatic films in combination with PERLUX or QGD blue emitting screens results in a considerable loss of sensitivity

  16. Electrochemical characterization of screen-printed and conventional carbon paste electrodes

    International Nuclear Information System (INIS)

    Fanjul-Bolado, Pablo; Hernandez-Santos, David; Lamas-Ardisana, Pedro Jose; Martin-Pernia, Alberto; Costa-Garcia, Agustin

    2008-01-01

    This work compares the electroactivity of a conventional carbon paste electrode and non-pretreated commercially available screen-printed carbon electrodes (from Alderon Biosciences, University of Florence and DropSens) towards some benchmark redox couples like hexaammineruthenium (III), ferricyanide, p-aminophenol and hydroquinone. While cyclic voltammograms of Ru 3+ did not show significative electron transfer reactivity differences between the electrodes tested, the other redox systems exhibited higher reversible behaviours on DropSens electrodes. Scanning electron microscopy and roughness analysis with a profilometer were applied to detect the surface morphology of the working electrodes. The roughness evaluated of the screen-printed carbon working electrodes increased in this order Alderon < University of Florence < DropSens. Finally, the most electrochemically active and rough unpretreated electrode (DropSens commercial screen-printed electrode) was used to study the electrochemical-chemical reaction mechanism of indigo carmine oxidation in 0.1 M sulphuric acid. This study showed that the adsorption of the oxidation product of indigo carmine is stabilized when it is adsorbed on the surface of the electrode

  17. Electrochemical characterization of screen-printed and conventional carbon paste electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Fanjul-Bolado, Pablo; Hernandez-Santos, David; Lamas-Ardisana, Pedro Jose [Departamento de Quimica Fisica y Analitica, Universidad de Oviedo, 33006 Oviedo, Asturias (Spain); Martin-Pernia, Alberto [Departamento de Ingenieria Electrica, Electronica de Computadores y Sistemas, Universidad de Oviedo, 33204 Gijon, Asturias (Spain); Costa-Garcia, Agustin [Departamento de Quimica Fisica y Analitica, Universidad de Oviedo, 33006 Oviedo, Asturias (Spain)], E-mail: costa@fq.uniovi.es

    2008-04-01

    This work compares the electroactivity of a conventional carbon paste electrode and non-pretreated commercially available screen-printed carbon electrodes (from Alderon Biosciences, University of Florence and DropSens) towards some benchmark redox couples like hexaammineruthenium (III), ferricyanide, p-aminophenol and hydroquinone. While cyclic voltammograms of Ru{sup 3+} did not show significative electron transfer reactivity differences between the electrodes tested, the other redox systems exhibited higher reversible behaviours on DropSens electrodes. Scanning electron microscopy and roughness analysis with a profilometer were applied to detect the surface morphology of the working electrodes. The roughness evaluated of the screen-printed carbon working electrodes increased in this order Alderon < University of Florence < DropSens. Finally, the most electrochemically active and rough unpretreated electrode (DropSens commercial screen-printed electrode) was used to study the electrochemical-chemical reaction mechanism of indigo carmine oxidation in 0.1 M sulphuric acid. This study showed that the adsorption of the oxidation product of indigo carmine is stabilized when it is adsorbed on the surface of the electrode.

  18. Superior performance of liquid-based versus conventional cytology in a population-based cervical cancer screening program

    NARCIS (Netherlands)

    Beerman, H.; van Dorst, E. B. L.; Kuenen-Boumeester, V.; Hogendoorn, P. C. W.

    Objective. Liquid-based cytology may offer improvements over conventional cytology for cervical cancer screening. The two cytology techniques were compared in a group of 86,469 women who participated in a population-based screening program. Using a nation-wide pathology database containing both

  19. Cervical cancer incidence after normal cytological sample in routine screening using SurePath, ThinPrep, and conventional cytology

    DEFF Research Database (Denmark)

    Rozemeijer, Kirsten; Naber, Steffie K; Penning, Corine

    2017-01-01

    of histo- and cytopathology in the Netherlands (PALGA), January 2000 to March 2013.Population Women with 5 924 474 normal screening samples (23 833 123 person years).Exposure Use of SurePath or ThinPrep versus conventional cytology as screening test.Main outcome measure 72 month cumulative incidence...

  20. Comparison of film/screen and PCR digital lateral cervical spine radiographs

    International Nuclear Information System (INIS)

    Silver, D.I.; Kreipke, D.L.; Tarver, R.; Braunstein, E.M.

    1988-01-01

    The authors compared film/screen and Phillips computed radiography (PCR) radiographs of the cervical spine. In 109 patients. fiilm/screen and digital radiographs were compared for adequate visualization (readability) of bone, soft tissue, and trachea. The lowest cervical vertebra seen was noted in each case. The radiographs were interpreted by four radiologists, and both interobserver and intraobserver consistency were measured. Of the PCR radiographs, 97% were readable with a viewbox alone. Of the film/screen radiographs, 9% were readable with a viewbox. With a hotlight, 83% of the film/screen radiographs became readable. Bone, soft tissue, and trachea were better seen on PCR radiographs than on film/screen radiographs (P<.001). There was less interobserver variation on digital radiographs. Readability of cervical spine radiographs was significantly improved with PCR

  1. Visibility of microcalcifications in computed and screen-film mammography

    International Nuclear Information System (INIS)

    Cowen, Arnold R.; Launders, Jason H.; Jadav, Mark; Brettle, David S.

    1997-01-01

    Due to the clinically and technically demanding nature of breast x-ray imaging, mammography still remains one of the few essentially film-based radiological imaging techniques in modern medical imaging. There are a range of possible benefits available if a practical and economical direct digital imaging technique can be introduced to routine clinical practice. There has been much debate regarding the minimum specification required for direct digital acquisition. One such direct digital system available is computed radiography (CR), which has a modest specification when compared with modern screen-film mammography (SFM) systems. This paper details two psychophysical studies in which the detection of simulated microcalcifications with CR has been directly compared to that with SFM. The first study found that under scatter-free conditions the minimum detectable size of micro calcification was approximately 130 μm for both SFM and CR. The second study found that SFM had a 4.6% higher probability of observers being able to correctly identify the shape of 350 μm diameter test details; there was no significant difference for either larger or smaller test details. From the results of these studies it has been demonstrated that the modest specification of CR, in terms of limiting resolution, does not translate into a dramatic difference in the perception of details at the limit of detectability. When judging the imaging performance of a system it is more important to compare the signal-to-noise ratio transfer spectrum characteristics, rather than simply the modulation transfer function. (author)

  2. Toxicological evaluation of natural rubber films from vulcanized latex by the conventional process and the alternative process with ionizing radiation

    International Nuclear Information System (INIS)

    Campos, Vania Elisabeth

    1997-01-01

    The industrial vulcanization of natural rubber latex (NRL) is made all over the world by conventional process using sulphur and heat but it can be made by an alternative process using ionizing radiation. In this research the NRL was tested by 13 physical, chemical and mechanical assays which showed its good quality. It was done a preliminary study of the toxicological properties of 4 natural rubber films obtained by casting process of NRL: one non vulcanized, other vulcanized by the conventional process and two vulcanized by the alternative process. In the alternative process the films were obtained by irradiation of NRL by gamma rays from the 60 Co source at 250 kGy in the absence of sensitizer and irradiated NRL at 12 kGy in the presence of 4ph r of n-butyl acrylate / 0.2 phr of KOH. These vulcanization doses were determined from broken tensile strength. In the conventional process, sulphur vulcanized NRL was made using a classical composition. Another film was made with non vulcanized NRL. The preliminary evaluation of the toxicological properties was made from in vitro cytotoxicity and in vivo systemic toxicity assays. The LBN films vulcanized by the alternative process have less cytotoxicity than the NRL film vulcanized by the conventional process. The sensitized vulcanized films by gamma rays and non vulcanized films showed similar cytotoxicity while the vulcanized films without sensitizer showed a slight lower cytotoxicity. The non vulcanized NRL film and the NRL films vulcanized by the alternative process did not show toxic effects int he 72 hours period of the systemic toxicity assay. However the NRL film vulcanized with sulphur induced effects like allaying and motor in coordination on the animals treated with an oil extract at the fourth hour and recovering after that. The alternative process promoted lower toxic effects than conventional process because there was no toxic substances present. (author)

  3. TXRF versus conventional EDXRF using 150 nm AP1 sample support films

    International Nuclear Information System (INIS)

    Wobrauschek, P.; Buzanich, G.; Marosi, N.

    2000-01-01

    Total reflection x-ray fluorescence analysis (TXRF ) is a powerful analytical tool for trace element analysis in the ng/g concentration or pg absolute region for medium Z elements using commercial or own designed TXRF equipment. One of the goals of TXRF is the extreme small penetration depth of the primary radiation into the reflector - substrate of 3-4 run if an incidence angle of about 1 mrad is adjusted. Among others, this effect results in a drastically reduced background in the measured spectra. This is caused by the reduction of elastic and inelastic scattered primary radiation from the substrate. Since there are now thin film supports commercially available having a thickness of 150 nm it is interesting to compare experimental results using TXRF and sample support films in 45 o incident beam and 45 o fluorescence emission geometry. As this film is only about 50 times more in thickness than the penetration depth in a quartz reflector, tests were performed to compare the analytical results and detection limits achievable from the same samples analyzed in total reflection geometry on a quartz reflector and conventional EDRXS geometry on the AP1 film with a dimple in the center for easy placing of the droplet. A volume of 3-5 μl of a liquid sample were used in both cases, pipetted and vacuum dried to prepare the sample. A high power 3 kW Mo-anode X-ray tube was used, for TXRF the line focus and for the conventional geometry the point focus was chosen. As additional results measurements from the TRACOR TN 5000 spectrometer will be presented using an air cooled low power tube with Rh - anode in a compact commercially available unit. A comparison of the results will be given in terms of sensitivity and detection limits, and future aspects for improvements and applications will be discussed. (author)

  4. [Comparison of film-screen combinations with contrast detail diagram and interactive image analysis. 2: Linear assessment of grey scale ranges with interactive image analysis].

    Science.gov (United States)

    Stamm, G; Eichbaum, G; Hagemann, G

    1997-09-01

    The following three screen-film combinations were compared: a) a combination of anticrossover film and UV-light emitting screens, b) a combination of blue-light emitting screens and film, and c) a conventional green fluorescing screen-film combination. Radiographs of a specially designed plexiglass phantom (0.2 x 0.2 x 0.12 m3) with bar patterns of lead and plaster and of air, respectively were obtained using the following parameters: 12 pulse generator, 0.6 mm focus size, 4.7 mm aluminum pre-filter, a grid with 40 lines/cm (12:1) and a focus-detector distance of 1.15 m. Image analysis was performed using an IBAS system and a Zeiss Kontron computer. Display conditions were the following: display distance 0.12 m, a vario film objective 35/70 (Zeiss), a video camera tube with a PbO photocathode, 625 lines (Siemens Heimann), an IBAS image matrix of 512 x 512 pixels with a resolution of 7 lines/mm, the projected matrix area was 5000 microns2. Grey scale ranges were measured on a line perpendicular to the grouped bar patterns. The difference between the maximum and minimum density value served as signal. The spatial resolution of the detector system was measured when the signal value was three times higher than the standard deviation of the means of multiple density measurements. The results showed considerable advantages of the two new screen-film combinations as compared to the conventional screen-film combination. The result was contradictory to the findings with pure visual assessment of thresholds (part I) that had found no differences. The authors concluded that (automatic) interactive image analysis algorithms serve as an objective measure and are specifically advantageous when small differences in image quality are to be evaluated.

  5. Roll-to-roll slot-die coating of 400 mm wide, flexible, transparent Ag nanowire films for flexible touch screen panels.

    Science.gov (United States)

    Kim, Dong-Ju; Shin, Hae-In; Ko, Eun-Hye; Kim, Ki-Hyun; Kim, Tae-Woong; Kim, Han-Ki

    2016-09-28

    We report fabrication of large area Ag nanowire (NW) film coated using a continuous roll-to-roll (RTR) slot die coater as a viable alternative to conventional ITO electrodes for cost-effective and large-area flexible touch screen panels (TSPs). By controlling the flow rate of shear-thinning Ag NW ink in the slot die, we fabricated Ag NW percolating network films with different sheet resistances (30-70 Ohm/square), optical transmittance values (89-90%), and haze (0.5-1%) percentages. Outer/inner bending, twisting, and rolling tests as well as dynamic fatigue tests demonstrated that the mechanical flexibility of the slot-die coated Ag NW films was superior to that of conventional ITO films. Using diamond-shape patterned Ag NW layer electrodes (50 Ohm/square, 90% optical transmittance), we fabricated 12-inch flexible film-film type and rigid glass-film-film type TSPs. Successful operation of flexible TSPs with Ag NW electrodes indicates that slot-die-coated large-area Ag NW films are promising low cost, high performance, and flexible transparent electrodes for cost-effective large-area flexible TSPs and can be substituted for ITO films, which have high sheet resistance and are brittle.

  6. Roll-to-roll slot-die coating of 400 mm wide, flexible, transparent Ag nanowire films for flexible touch screen panels

    Science.gov (United States)

    Kim, Dong-Ju; Shin, Hae-In; Ko, Eun-Hye; Kim, Ki-Hyun; Kim, Tae-Woong; Kim, Han-Ki

    2016-09-01

    We report fabrication of large area Ag nanowire (NW) film coated using a continuous roll-to-roll (RTR) slot die coater as a viable alternative to conventional ITO electrodes for cost-effective and large-area flexible touch screen panels (TSPs). By controlling the flow rate of shear-thinning Ag NW ink in the slot die, we fabricated Ag NW percolating network films with different sheet resistances (30-70 Ohm/square), optical transmittance values (89-90%), and haze (0.5-1%) percentages. Outer/inner bending, twisting, and rolling tests as well as dynamic fatigue tests demonstrated that the mechanical flexibility of the slot-die coated Ag NW films was superior to that of conventional ITO films. Using diamond-shape patterned Ag NW layer electrodes (50 Ohm/square, 90% optical transmittance), we fabricated 12-inch flexible film-film type and rigid glass-film-film type TSPs. Successful operation of flexible TSPs with Ag NW electrodes indicates that slot-die-coated large-area Ag NW films are promising low cost, high performance, and flexible transparent electrodes for cost-effective large-area flexible TSPs and can be substituted for ITO films, which have high sheet resistance and are brittle.

  7. Impact of a CAD system in a screen-film mammography screening program: A prospective study

    International Nuclear Information System (INIS)

    Sanchez Gómez, S.; Torres Tabanera, M.; Vega Bolivar, A.; Sainz Miranda, M.; Baroja Mazo, A.; Ruiz Diaz, M.; Martinez Miravete, P.; Lag Asturiano, E.; Muñoz Cacho, P.; Delgado Macias, T.

    2011-01-01

    Objective: The purpose of our study was to perform a prospective assessment of the impact of a CAD system in a screen-film mammography screening program during a period of 3 years. Materials and methods: Our study was carried out on a population of 21,855 asymptomatic women (45–65 years). Mammograms were processed in a CAD system and independently interpreted by one of six radiologists. We analyzed the following parameters: sensitivity of radiologist's interpretation (without and with CAD), detection increase, recall rate and positive predictive value of biopsy, CAD's marks, radiologist's false negatives and comparative analysis of carcinomas detected and non-detected by CAD. Results: Detection rate was 4.3‰. CAD supposed an increase of 0.1‰ in detection rate and 1% in the total number of cases (p < 0.005). The impact on recall rate was not significant (0.4%) and PPV of percutaneous biopsy was unchanged by CAD (20.23%). CAD's marks were 2.7 per case and 0.7 per view. Radiologist's false negatives were 13 lesions which were initially considered as CAD's false positives. Conclusions: CAD supposed a significant increase in detection, without modifications in recall rates and PPV of biopsy. However, better results could have been achieved if radiologists had considered actionable those cases marked by CAD but initially misinterpreted.

  8. The Effect of Lead Intensification Screens on Film: Modeling and Experiment

    International Nuclear Information System (INIS)

    Wendt, S.; Gray, J.; Zhou, C.

    2004-01-01

    A physics-based, intensification screen model, using lead as an example, has been developed. Comparisons to experimental results are shown. The dominant effect in producing the intensification is from photoelectrons ejected from a 24 - 40 micron layer of lead near the film with Compton electrons and the lead fluorescence x-rays contributing less than 10% to the intensification for settings below 300 kvp. The thickness of lead screen for optimal intensification is between 15 and 70 microns depending upon the energy of the photon. This is less than the traditional practice of a 130 microns front screen and 260 microns back screen. The model computes the intensifying effect of lead screens placed in front or in back of a sheet of radiographic film and accounts for the strong energy dependent effects contributing to the intensification. The lead screen model is independent of film type, so the user can select any type of film and any combination of lead thickness for the front and back screens. The model uses energy dependent x-ray photon absorption cross-sections to compute the production of electrons in the lead. A Monte Carlo calculation was used to determine energy dependent electron penetration in the lead and the film. The model calculates electron attenuation in the film emulsion, the film substrate and both front and back lead screens and determines the intensification effect as a function of the energy deposited in the film. For model validation, lead screen intensification was studied with x-ray generator settings ranging from 75 to 320 kvp and using various thicknesses of aluminum and iron attenuators to filter the x-ray beam. A high precision motion control system coupled with a high purity germanium detector was used to study the energy spectra

  9. Screening for depression in epilepsy clinics. A comparison of conventional and visual-analog methods.

    Science.gov (United States)

    Rampling, Jeremy; Mitchell, Alex J; Von Oertzen, Tim; Docker, James; Jackson, Jemima; Cock, Hannah; Agrawal, Niruj

    2012-10-01

    Depression is an important but underdiagnosed complication of epilepsy. This study compares potentially suitable screening tools head-to-head. We enrolled 266 attendees with a confirmed diagnosis of epilepsy at a specialized neurologic epilepsy service in London and compared verbal self-report and visual analog (VAS) screening methods for depression. These included two generic depression scales (Hospital Anxiety and Depression Scale [HADS], Beck Depression Inventory II [BDI-II]), one epilepsy specific scale (Neurological Disorders Depression Inventory for Epilepsy [NDDI-E]) and one new visual-analog scale (Emotional Thermometers [ET]). We used Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV) criteria for major depression and International Classification of Diseases, Tenth Revision (ICD-10) criteria for depressive episode as the reference standard. Against ICD-10-defined depression the most accurate scales by receiver operating characteristic (ROC) curve area were HADS Total (HADS-T, 0.924), BDI-II (0.898) and NDDI-E (0.897). New visual-analog methods had similar accuracy measured either in combination or individually. Although no test performed well in a case-finding role, several performed well as a rule-out initial step, owing to high negative predictive value and specificity. In this role, the optimal performing conventional tools were the HADS depression subsscale (HADS-D) and the NDDI-E and the optimal single VAS were the depression thermometer (DepT) and the distress thermometer (DT). Against DSM-IV- defined major depression, results were similar with optimal performance by the HADS-T, BDI-II, and NDDI-E, but here the anxiety thermometer (AnxT) as well as DepT and DT also offered good performance. Given that no test performed well in a case-finding role, we suggest that these tests are used as an initial first step to rule out patients who are unlikely to have depression. We suggest that the six-item NDDI-E or seven-item HADS

  10. Quality Imaging - Comparison of CR Mammography with Screen-Film Mammography

    International Nuclear Information System (INIS)

    Gaona, E.; Azorin Nieto, J.; Iran Diaz Gongora, J. A.; Arreola, M.; Casian Castellanos, G.; Perdigon Castaneda, G. M.; Franco Enriquez, J. G.

    2006-01-01

    The aim of this work is a quality imaging comparison of CR mammography images printed to film by a laser printer with screen-film mammography. A Giotto and Elscintec dedicated mammography units with fully automatic exposure and a nominal large focal spot size of 0.3 mm were used for the image acquisition of phantoms in screen-film mammography. Four CR mammography units from two different manufacturers and three dedicated x-ray mammography units with fully automatic exposure and a nominal large focal spot size of 0.3 mm were used for the image acquisition of phantoms in CR mammography. The tests quality image included an assessment of system resolution, scoring phantom images, Artifacts, mean optical density and density difference (contrast). In this study, screen-film mammography with a quality control program offers a significantly greater level of quality image relative to CR mammography images printed on film

  11. High Throughput Screening of Valganciclovir in Acidic Microenvironments of Polyester Thin Films

    Directory of Open Access Journals (Sweden)

    Teilo Schaller

    2015-04-01

    Full Text Available Ganciclovir and valganciclor are antiviral agents used for the treatment of cytomegalovirus retinitis. The conventional method for administering ganciclovir in cytomegalovirus retinitis patients is repeated intravitreal injections. In order to obviate the possible detrimental effects of repeated intraocular injections, to improve compliance and to eliminate systemic side-effects, we investigated the tuning of the ganciclovir pro-drug valganciclovir and the release from thin films of poly(lactic-co-glycolic acid (PLGA, polycaprolactone (PCL, or mixtures of both, as a step towards prototyping periocular valganciclovir implants. To investigate the drug release, we established and evaluated a high throughput fluorescence-based quantification screening assay for the detection of valganciclovir. Our protocol allows quantifying as little as 20 ng of valganciclovir in 96-well polypropylene plates and a 50× faster analysis compared to traditional HPLC measurements. This improvement can hence be extrapolated to other polyester matrix thin film formulations using a high-throughput approach. The acidic microenvironment within the polyester matrix was found to protect valganciclovir from degradation with resultant increases in the half-life of the drug in the periocular implant to 100 days. Linear release profiles were obtained using the pure polyester polymers for 10 days and 60 days formulations; however, gross phase separations of PCL and acid-terminated PLGA prevented tuning within these timeframes due to the phase separation of the polymer, valganciclovir, or both.

  12. Comparison of computed tomography scout based reference point localization to conventional film and axial computed tomography.

    Science.gov (United States)

    Jiang, Lan; Templeton, Alistair; Turian, Julius; Kirk, Michael; Zusag, Thomas; Chu, James C H

    2011-01-01

    Identification of source positions after implantation is an important step in brachytherapy planning. Reconstruction is traditionally performed from films taken by conventional simulators, but these are gradually being replaced in the clinic by computed tomography (CT) simulators. The present study explored the use of a scout image-based reconstruction algorithm that replaces the use of traditional film, while exhibiting low sensitivity to metal-induced artifacts that can appear in 3D CT methods. In addition, the accuracy of an in-house graphical software implementation of scout-based reconstruction was compared with seed location reconstructions for 2 phantoms by conventional simulator and CT measurements. One phantom was constructed using a planar fixed grid of 1.5-mm diameter ball bearings (BBs) with 40-mm spacing. The second was a Fletcher-Suit applicator embedded in Styrofoam (Dow Chemical Co., Midland, MI) with one 3.2-mm-diameter BB inserted into each of 6 surrounding holes. Conventional simulator, kilovoltage CT (kVCT), megavoltage CT, and scout-based methods were evaluated by their ability to calculate the distance between seeds (40 mm for the fixed grid, 30-120 mm in Fletcher-Suit). All methods were able to reconstruct the fixed grid distances with an average deviation of <1%. The worst single deviations (approximately 6%) were exhibited in the 2 volumetric CT methods. In the Fletcher-Suit phantom, the intermodality agreement was within approximately 3%, with the conventional sim measuring marginally larger distances, with kVCT the smallest. All of the established reconstruction methods exhibited similar abilities to detect the distances between BBs. The 3D CT-based methods, with lower axial resolution, showed more variation, particularly with the smaller BBs. With a software implementation, scout-based reconstruction is an appealing approach because it simplifies data acquisition over film-based reconstruction without requiring any specialized equipment

  13. CdTe polycrystalline films on Ni foil substrates by screen printing and their photoelectric performance

    International Nuclear Information System (INIS)

    Yao, Huizhen; Ma, Jinwen; Mu, Yannan; Su, Shi; Lv, Pin; Zhang, Xiaoling; Zhou, Liying; Li, Xue; Liu, Li; Fu, Wuyou; Yang, Haibin

    2015-01-01

    Highlights: • The sintered CdTe polycrystalline films by a simple screen printing. • The flexible Ni foil was chose as substrates to reduce the weight of the electrode. • The compact CdTe film was obtained at 550 °C sintering temperature. • The photoelectric activity of the CdTe polycrystalline films was excellent. - Abstract: CdTe polycrystalline films were prepared on flexible Ni foil substrates by sequential screen printing and sintering in a nitrogen atmosphere for the first time. The effect of temperature on the quality of the screen-printed film was investigated in our work. The high-quality CdTe films were obtained after sintering at 550 °C for 2 h. The properties of the sintered CdTe films were characterized by scanning electron microscopy, X-ray diffraction pattern and UV–visible spectroscopy. The high-quality CdTe films have the photocurrent was 2.04 mA/cm 2 , which is higher than that of samples prepared at other temperatures. Furthermore, CdCl 2 treatment reduced the band gap of the CdTe film due to the larger grain size. The photocurrent of photoelectrode based on high crystalline CdTe polycrystalline films after CdCl 2 treatment improved to 2.97 mA/cm 2 , indicating a potential application in photovoltaic devices

  14. Study on Gas Sensing Performance of TiO2 Screen Printed Thick Films

    Directory of Open Access Journals (Sweden)

    C. G. DIGHAVKAR

    2009-02-01

    Full Text Available Titanium dioxide (TiO2 thick films were prepared on alumina substrate by using screen printing technique. After preparation, the films were fired at temperature range 600 -1000 ºC for two hour. Morphological, compositional and structural properties of the film samples were performed by means of several techniques, including scanning electron microscopy (SEM, Energy dispersive spectroscopy (EDS, X-ray diffraction techniques. We explore the various gases to study the sensing performance of the TiO2 thick films. The maximum response was reported to film fired at 800 0C for LPG gas at 350 0C operating temperature.

  15. Pulsed Polarization-Based NOx Sensors of YSZ Films Produced by the Aerosol Deposition Method and by Screen-Printing.

    Science.gov (United States)

    Exner, Jörg; Albrecht, Gaby; Schönauer-Kamin, Daniela; Kita, Jaroslaw; Moos, Ralf

    2017-07-26

    The pulsed polarization technique on solid electrolytes is based on alternating potential pulses interrupted by self-discharge pauses. Since even small concentrations of nitrogen oxides (NO x ) in the ppm range significantly change the polarization and discharge behavior, pulsed polarization sensors are well suited to measure low amounts of NO x . In contrast to all previous investigations, planar pulsed polarization sensors were built using an electrolyte thick film and platinum interdigital electrodes on alumina substrates. Two different sensor layouts were investigated, the first with buried Pt electrodes under the electrolyte and the second one with conventional overlying Pt electrodes. Electrolyte thick films were either formed by aerosol deposition or by screen-printing, therefore exhibiting a dense or porous microstructure, respectively. For screen-printed electrolytes, the influence of the electrolyte resistance on the NO x sensing ability was investigated as well. Sensors with buried electrodes showed little to no response even at higher NO x concentrations, in good agreement with the intended sensor mechanism. Electrolyte films with overlying electrodes, however, allowed the quantitative detection of NO x . In particular, aerosol deposited electrolytes exhibited high sensitivities with a sensor output signal Δ U of 50 mV and 75 mV for 3 ppm of NO and NO₂, respectively. For screen-printed electrolytes, a clear trend indicated a decrease in sensitivity with increased electrolyte resistance.

  16. High-contrast resolution of film-screen systems in oral and maxillofacial radiology

    International Nuclear Information System (INIS)

    Kaeppler, G.; Reinert, S.

    2007-01-01

    Purpose: The aim was to determine differences in high-contrast resolution of film-screen systems used in dental panoramic and cephalometric radiography by calculating the modulation transfer function (MTF). The radiographs used to determine the MTF should be taken by the same X-ray units as those used for patient radiographs. Materials and methods: The MTF was determined using a lead grid and according to DIN 6867 - 2 for 11 film-screen systems (speed 250, speed class 200 and 400) used in dental radiographic diagnostics. The optical density was measured using a microdensitometer developed by PTB. Results: With 10% of the modulation transfer factor, newly developed film-screen systems (speed class 200 and 400) demonstrated a resolution of 4.9 to 6 line pairs per mm (panoramic radiography). In cephalometric radiography a film-screen system (speed class 400 and green-sensitive film) had a resolution of 4.2 line pairs per mm and surpassed two film-screen systems (speed class 400, resolution of 3 line pairs per mm, blue-sensitive films). (orig.)

  17. Comparison of Diagnostic Accuracy of Breast Masses Using Digitized Images Versus Screen-Film Mammography

    International Nuclear Information System (INIS)

    Zhigang Liang; Xiangying Du; Jiabin Liu; Xinyu Yao; Yanhui Yang; Kuncheng Li

    2008-01-01

    Background: Medical film digitizers play an important transitory role as digital-analogue bridges in radiology. Digitized mammograms require evaluation of performance to assure medical image quality. Purpose: To compare the diagnostic accuracy in the interpretation of breast masses using original screen-film mammograms versus digitized images. Material and Methods: A total of 72 female patients between 55 and 81 years of age suspected of having breast cancer were selected by two non-observing radiologists. Of these, 31 cases were benign lesions and 41 cases were cancer. The mammography films were digitized using a laser film digitizer. Three radiologists, each with more than 10 years of experience in mammography, interpreted the screen-film mammograms and digitized images respectively. The time interval was 4 weeks. A four-point malignancy scale was used, with 1 defined as definitely not malignant, 2 as probably not malignant, 3 as probably malignant, and 4 as definitely malignant. Receiver operating characteristic (Roc) curves, sensitivity, and specificity were compared. Results: The average area-under-the-curve (Az) value of the original screen-film mammograms was 0.921, and the average Az value of the digitized images was 0.859. This difference was not statistically significant (P=0.131). The detection specificity of extremely dense breasts was lower than that for other breast compositions for both digitized images and screen-film mammograms. No statistical significance in sensitivity and specificity was observed between digitized images and mammograms for each breast composition. Original screen-film mammograms were observed to perform better than digitized images. Conclusion: Digitized images with a spatial resolution of 175 μm can be used instead of screen-film mammograms in the diagnosis of breast cancer

  18. Comparison of the quality of the chest film between digital radiography and conventional high kV radiography

    International Nuclear Information System (INIS)

    Zeng Qingsi; Cen Renli; Chen Ling; He Jianxun; Lin Hanfei

    2003-01-01

    Objective: To evaluate the quality and usefulness of direct digital radiography system in roentgenogram of chest in clinical practice. Methods: 1000 cases of chest roentgenograms with digital radiography and high kV conventional radiography were selected for analysis by 3 senior radiologists. Results: 1. With digital radiography system, the quality of chest film was assessed as grade A in 50.6%, grade B in 38.5%, grade C in 10.9%, and no waste film. 2. With conventional high kV radiography, the quality of chest film was assessed as grade A in 41.1%, grade B in 44.1%, grade C in 13.3%, and waste film in 1.5%. The direct digital radiography was statistically superior to the conventional high kV radiography. 3. The fine structure of the lungs could be revealed in 100.0% of chest roentgenogram with direct digital radiograph system, which was significantly higher than that acquired with the conventional high KV radiography (78.6%, P < 0.001). Conclusion: Direct digital radiography could provide the chest film with better quality than that with the conventional high kV radiography. The direct digital radiography system is easy to operate, fast in capturing imaging and could provide post-processing techniques, which will facilitate the accurate diagnosis of chest radiography

  19. Underestimation of substance abuse in psychiatric patients by conventional hospital screening.

    Science.gov (United States)

    Reidy, Lisa J; Junquera, Patricia; Van Dijck, Karolien; Steele, Bernard W; Nemeroff, Charles B

    2014-12-01

    Psychiatric diagnosis mainly relies on behavioral signs and symptoms. Substance abuse can mimic the clinical presentation of primary psychiatric disorders and can also complicate the management of psychiatric patients. The reliability and accuracy of urine toxicology is a vital tool in the optimal treatment of these patients. Current demographics of substance abuse suggest that in addition to the most conventional drugs of abuse (e.g. cocaine, cannabis) that are of concern to treating physicians, prescription medications and new designer drugs also should be when evaluating patients who present with symptoms of psychosis/drug addiction or altered mental status. Urine samples from 220 psychiatric inpatients admitted to either an acute drug and alcohol unit or acute psychiatric unit were analyzed for drugs by the standard hospital assay (KIMS) and by a more sensitive ELISA and GC-MS basic drug screening protocol. The standard hospital toxicology (KIMS) was inferior to the ELISA and GC-MS methods in terms of both assay sensitivity and in detecting a broader number of drugs. The KIMS tests failed to identify opiates and amphetamine/methamphetamine in 50% of the patients. The KIMS screen did not identify zolpidem, buprenorphine and a number of synthetic drugs of abuse including cathinone and tryptamines. In order to reliably identify substance abuse in patients with altered mental status in inpatient settings, analytical methodologies with adequate assay sensitivity and range to detect the vast majority of commonly abused illicit drugs and prescription medications are required for optimal clinical assessment and treatment. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Digital radiography with a large-scale electronic flat-panel detector vs screen-film radiography: observer preference in clinical skeletal diagnostics

    International Nuclear Information System (INIS)

    Hamers, S.; Freyschmidt, J.; Neitzel, U.

    2001-01-01

    The imaging performance of a recently developed digital flat-panel detector system was compared with conventional screen-film imaging in an observer preference study. In total, 34 image pairs of various regions of the skeleton were obtained in 24 patients; 30 image pairs were included in the study. The conventional images were acquired with 250- and 400-speed screen-film combinations, using the standard technique of our department. Within hours, the digital images were obtained using identical exposure parameters. The digital system employed a large-area (43 x 43 cm) flat-panel detector based on amorphous silicon (Trixell Pixium 4600), integrated in a Bucky table. Six radiologists independently evaluated the image pairs with respect to image latitude, soft tissue rendition, rendition of the periosteal and enosteal border of cortical bone, rendition of cancellous bone and the visibility of potentially present pathological changes, using a subjective five-point scale. The digital images were rated significantly (p=0.001) better than the screen-film images with respect to soft tissue rendition and image latitude. Also the rendition of the cancellous bone and the periosteal and enosteal border of the cortical bone was rated significantly (p=0.05) better for the flat-panel detector. The visibility of pathological lesions was equivalent; only large-area sclerotic lesions (n=2) were seen superiorly on screen-film images. The new digital flat-panel detector based on amorphous silicon appears to be at least equivalent to conventional screen-film combinations for skeletal examinations, and in most respects even superior. (orig.)

  1. A comparison of the performance of modern screen-film and digital mammography systems

    Energy Technology Data Exchange (ETDEWEB)

    Monnin, P [Institut Universitaire de Radiophysique Appliquee (IRA), CH-1007 Lausanne (Switzerland); Gutierrez, D [Institut Universitaire de Radiophysique Appliquee (IRA), CH-1007 Lausanne (Switzerland); Bulling, S [Institut Universitaire de Radiophysique Appliquee (IRA), CH-1007 Lausanne (Switzerland); Lepori, D [Department of Radiology, University Hospital Center (CHUV), CH-1011 Lausanne (Switzerland); Valley, J-F [Institut Universitaire de Radiophysique Appliquee (IRA), CH-1007 Lausanne (Switzerland); Verdun, F R [Institut Universitaire de Radiophysique Appliquee (IRA), CH-1007 Lausanne (Switzerland)

    2005-06-07

    This work compares the detector performance and image quality of the new Kodak Min-R EV mammography screen-film system with the Fuji CR Profect detector and with other current mammography screen-film systems from Agfa, Fuji and Kodak. Basic image quality parameters (MTF, NPS, NEQ and DQE) were evaluated for a 28 kV Mo/Mo (HVL = 0.646 mm Al) beam using different mAs exposure settings. Compared with other screen-film systems, the new Kodak Min-R EV detector has the highest contrast and a low intrinsic noise level, giving better NEQ and DQE results, especially at high optical density. Thus, the properties of the new mammography film approach those of a fine mammography detector, especially at low frequency range. Screen-film systems provide the best resolution. The presampling MTF of the digital detector has a value of 15% at the Nyquist frequency and, due to the spread size of the laser beam, the use of a smaller pixel size would not permit a significant improvement of the detector resolution. The dual collection reading technology increases significantly the low frequency DQE of the Fuji CR system that can at present compete with the most efficient mammography screen-film systems.

  2. Optical properties of flexible fluorescent films prepared by screen printing technology

    Directory of Open Access Journals (Sweden)

    Yan Chen

    2018-05-01

    Full Text Available In this work, we prepared a fluorescent film comprised phosphors and silicone on flexible polyethylene terephthalate (PET substrate using a screen printing technology. The effects of mesh number and weight ratio of phosphors to silicone on the optical properties of the flexible films were investigated. The results indicate that the emission intensity of the film increase as the mesh decreased from 400 to 200, but the film surface gradually becomes uneven. The fluorescent film with high emission intensity and smooth surface can be obtained when the weight ratio of phosphor to gel is 2:1, and mesh number is 300. The luminous efficiency of the fabricated LEDs combined the fluorescent films with 460 nm Ga(InN chip module can reach 75 lm/W. The investigation indicates that the approach can be applied in the remote fluorescent film conversion and decreases the requirements of the particle size and the dispersion state of fluorescent materials.

  3. Optical properties of flexible fluorescent films prepared by screen printing technology

    Science.gov (United States)

    Chen, Yan; Ke, Taiyan; Chen, Shuijin; He, Xin; Zhang, Mei; Li, Dong; Deng, Jinfeng; Zeng, Qingguang

    2018-05-01

    In this work, we prepared a fluorescent film comprised phosphors and silicone on flexible polyethylene terephthalate (PET) substrate using a screen printing technology. The effects of mesh number and weight ratio of phosphors to silicone on the optical properties of the flexible films were investigated. The results indicate that the emission intensity of the film increase as the mesh decreased from 400 to 200, but the film surface gradually becomes uneven. The fluorescent film with high emission intensity and smooth surface can be obtained when the weight ratio of phosphor to gel is 2:1, and mesh number is 300. The luminous efficiency of the fabricated LEDs combined the fluorescent films with 460 nm Ga(In)N chip module can reach 75 lm/W. The investigation indicates that the approach can be applied in the remote fluorescent film conversion and decreases the requirements of the particle size and the dispersion state of fluorescent materials.

  4. The relationship of over density to overexposure each film/screen systems in chest radiography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Min; Huo Joon [Korea University, Seoul (Korea, Republic of); Taro, Hayash; Yuji, Ishida; Tatsuya, Sakurai [The Chemotherapeutic Istitute Hospital, Tokyo (Japan)

    1999-06-01

    This study is to calculate the exposed radiation dose using Bit method, NDD calculation method and monogram method without dosimeter. In addition,we can calculate the radiation dose from x-ray film density as a film badge. The authors examined the entrance skin dose from 2 {approx} 3 intercostal chest x-ray film density. We also studied the relationship between film density and equivalent dose in the each screen film system under the different radiation quality and the poor geometry condition of grid ratio. As results, we established the deductive method to define the entrance skin dose from chest x-ray film density. The error range was found in the range -13 percent {approx} +17 percent for between deductive entrance skin dose and the 2 {approx} 3 inter coastal chest x-ray film density to actual detective radiation dose with dosimeter. (author)

  5. Detection of pulmonary nodules. Improvement by new screen-film systems?

    International Nuclear Information System (INIS)

    Lehmann, K.J.; Himmighoefer, U.

    1994-01-01

    In addition to digital radiography and AMBER, the development of asymmetric screen-film systems is another attempt to optimize chest radiography. Due to reduced contrast in the parenchyma, the former asymmetric screen-film systems did not show sufficient image quality. Three new asymmetric systems with completely different composition are available now. In-Sight VHC (Kodak), High Light GUV (3M) and Opthos D (Agfa) were compared to standard chest films using densitometric curves, a chest phantom for high and low contrast detectability, a nodule detection phantom and patient studies. The sensitivity of nodule detection in the mediastinum has been 41-48% for L-films and 58-65% for the asymmetric screen-film systems. No differences could be demonstrated for nodule detection in the lung field. Contrast in the parenchyma is equivalent to L-films. There is no loss of diagnostic information in the lung field. Differences between the asymmetric systems concern speed, dynamic range and granularity. If AMBER and digital radiography are not available, new asymmetric screen-film systems can improve nodule detection without further investment costs. (orig.) [de

  6. Short-term annealing of mixed amorphous molybdenum-silicon films by means of a conventional diffusion equipment

    International Nuclear Information System (INIS)

    Kaufmann, C.; Raschke, T.; Rockoff, A.; Temmler, D.

    1985-01-01

    A short-term annealing procedure is described of mixed amorphous Mo-Si films in a retrofitted conventional diffusion equipment. By means of a special charging jig it is possible to siliconize repeatably between 1 and 120 s in oxygen-free atmosphere. The heat-treated films transform into crystalline MoSi 2 films at temperatures of 1100 0 C and 1200 0 C, respectively, and attain resistance values which correspond to a one-hour treatment at temperatures of 900 0 C up to 1000 0 C. Therefore, the procedure could be used for the production of VLSI circuits with silicide metallization. After short-term annealing the MoSi 2 films show smaller grain sizes compared to conventionally annealed samples

  7. NUMERICAL SIMULATION OF MAGNETIC FIELD STRUCTURE IN CYLINDRICAL FILM SCREEN

    Directory of Open Access Journals (Sweden)

    G. F. Gromyko

    2016-01-01

    Full Text Available A numerical method for solving the boundary value problem for a nonlinear magnetostatic equation describing the external magnetostatic field penetration through the cylindrical film coating is developed. A mathematical model of the shielding problem based on the use of the boundary conditions of the third kind on the film surface is studied. The nonlinear dependence of the film magnetic permeability on magnetic field conforms with experimental data. The distribution of the magnetic field strength in the film layer and the magnetic permeability of the film material depending on the magnitude of the external magnetic field strength are investigated numerically.

  8. Electron field emission from screen-printed graphene/DWCNT composite films

    International Nuclear Information System (INIS)

    Xu, Jinzhuo; Pan, Rong; Chen, Yiwei; Piao, Xianqin; Qian, Min; Feng, Tao; Sun, Zhuo

    2013-01-01

    Highlights: ► The field emission performance improved significantly when adding graphene into DWCNTs as the emission material. ► We set up a model of pure DWCNT films and graphene/DWCNT composite films. ► We discussed the contact barrier between emission films and electric substrates by considering the Fermi energies of silver, DWCNT and graphene. - Abstract: The electron field emission properties of graphene/double-walled carbon nanotube (DWCNT) composite films prepared by screen printing have been systematically studied. Comparing with the pure DWCNT films and pure graphene films, a significant enhancement of electron emission performance of the composite films are observed, such as lower turn-on field, higher emission current density, higher field enhancement factor, and long-term stability. The optimized composite films with 20% weight ratio of graphene show the best electron emission performance with a low turn-on field of 0.62 V μm −1 (at 1 μA cm −2 ) and a high field enhancement factor β of 13,000. A model of the graphene/DWCNT composite films is proposed, which indicate that a certain amount of graphene will contribute the electron transmission in the silver substrate/composite films interface and in the interior of composite films, and finally improve the electron emission performance of the graphene/DWCNT composite films.

  9. Screen film vs full-field digital mammography: image quality, detectability and characterization of lesions

    International Nuclear Information System (INIS)

    Obenauer, S.; Luftner-Nagel, S.; Heyden, D. von; Baum, F.; Grabbe, E.; Munzel, U.

    2002-01-01

    The objective of this study was to compare screen-film mammography (SFM) to full-field digital mammography (FFDM) regarding image quality as well as detectability and characterization of lesions using equivalent images of the same patient acquired with both systems. Two mammography units were used, one with a screen-film system (Senographe DMR) and the other with a digital detector (Senographe 2000D, both GEMS). Screen-film and digital mammograms were performed on 55 patients with cytologically or histologically proven tumors on the same day. Together with these, 75 digital mammograms of patients without tumor and the corresponding previous screen-film mammograms not older than 1.5 years were reviewed by three observers in a random order. Contrast, exposure, and the presence of artifacts were evaluated. Different details, such as the skin, the retromamillary region, and the parenchymal structures, were judged according to a three-point ranking scale. Finally, the detectability of microcalcifications and lesions were compared and correlated to histology. Image contrast was judged to be good in 76%, satisfactory in 20%, and unsatisfactory in 4% of screen-film mammograms. Digital mammograms were judged to be good in 99% and unsatisfactory in 1% of cases. Improper exposure of screen-film system occurred in 18% (10% overexposed and 8% underexposed). Digital mammograms were improperly exposed in 4% of all cases but were of acceptable quality after post-processing. Artifacts, most of them of no significance, were found in 78% of screen-film and in none of the digital mammograms. Different anatomical regions, such as the skin, the retromamillary region, and dense parenchymal areas, were better visualized in digital than in screen-film mammography. All malignant tumors were seen by the three radiologists; however, digital mammograms allowed a better characterization of these lesions to the Breast Imaging Reporting and Data System (BI-RADSZZZ;) categories (FFDM better than

  10. Experiences with a new film-screen system in pediatric chest radiography

    International Nuclear Information System (INIS)

    Leenen, A.; Brandt, G.A.; Riebel, T.; Marciniak, H.

    1996-01-01

    Purpose: To compare the X-ray images made by the Kodak InSight Pediatric Imaging System (InSight P) with conventional film-screen systems in pediatric chest radiography. Material and methods: The comparison involved chest radiographs made using Quanta-Fast-Detail/Cronex 4 (DuPont), Trimax 16/XDA (3 M) and DuPont UVR/UVL systems. The image quality of critical structures and the physical parameters of quantum interference, contrast and resolution were assessed. The energy path of the system was assessed by preparing density curves. Test conditions were in accordance with the latest guidelines of the Bundesaerztekammer (German Physicians' Association). Results: The mediastinal area, retrocardiac and paravertebral spaces and the peripheral vessels of the lung were all displayed more distinctly using InSight P. The reason for this seems to be a lower degree of quantum interference associated with this system. With tube voltages between 60 and 80 kV, InSight P displayed a relatively low degree of sensitivity. Conclusion: InSight P can be used to produce predominantly high quality chest radiographs on infants between one and five years of age. However, this system has limited sensitivity in the tube voltage range recommended by the German Physicians' Association. (orig.) [de

  11. Screen-printed Tin-doped indium oxide (ITO) films for NH3 gas sensing

    International Nuclear Information System (INIS)

    Mbarek, Hedia; Saadoun, Moncef; Bessais, Brahim

    2006-01-01

    Gas sensors using metal oxides have several advantageous features such as simplicity in device structure and low cost fabrication. In this work, Tin-doped indium oxide (ITO) films were prepared by the screen printing technique onto glass substrates. The granular and porous structure of screen-printed ITO are suitable for its use in gas sensing devices. The resistance of the ITO films was found to be strongly dependent on working temperatures and the nature and concentration of the ambient gases. We show that screen-printed ITO films have good sensing properties toward NH 3 vapours. The observed behaviors are explained basing on the oxidizing or the reducer nature of the gaseous species that react on the surface of the heated semi-conducting oxide

  12. Correlation of conventional simulation x-ray films and CT images for HDR-brachytherapy catheters reconstruction

    International Nuclear Information System (INIS)

    Rajendran, M.; Reddy, K.D.; Reddy, R.M.; Reddy, J.M.; Reddy, B.V.N.; Kiran Kumar; Gopi, S.; Dharaniraj; Janardhanan

    2002-01-01

    In order to plan a brachytherapy implant, it is imperative that implant reconstruction is done accurately. The purpose of this paper is to evaluate whether implant reconstruction done with transverse CT images is comparable to reconstruction done with conventional x-ray films

  13. Performances of screen-printing silver thick films: Rheology, morphology, mechanical and electronic properties

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Jung-Shiun; Liang, Jau-En; Yi, Han-Liou [Department of Chemical Engineering, National Chung Cheng University, Chia Yi 621, Taiwan, ROC (China); Chen, Shu-Hua [China Steel Corporation, Kaohsiung City 806, Taiwan, ROC (China); Hua, Chi-Chung, E-mail: chmcch@ccu.edu.tw [Department of Chemical Engineering, National Chung Cheng University, Chia Yi 621, Taiwan, ROC (China)

    2016-06-15

    Numerous recent applications with inorganic solar cells and energy storage electrodes make use of silver pastes through processes like screen-printing to fabricate fine conductive lines for electron conducting purpose. To date, however, there have been few studies that systematically revealed the properties of the silver paste in relation to the mechanical and electronic performances of screen-printing thick films. In this work, the rheological properties of a series of model silver pastes made of silver powders of varying size (0.9, 1.3, and 1.5 μm) and shape (irregular and spherical) were explored, and the results were systematically correlated with the morphological feature (scanning electron microscopy, SEM) and mechanical (peeling test) and electronic (transmission line method, TLM) performances of screen-printing dried or sintered thick films. We provided evidence of generally intimate correlations between the powder dispersion state in silver pastes—which is shown to be well captured by the rheological protocols employed herein—and the performances of screen-printing thick films. Overall, this study suggests the powder dispersion state and the associated phase behavior of a paste sample can significantly impact not only the morphological and electronic but also mechanical performances of screen-printing thick films, and, in future perspectives, a proper combination of silver powders of different sizes and even shapes could help reconcile quality and stability of an optimum silver paste. - Highlights: • Powder dispersion correlates well with screen-printing thick film performances. • Rheological fingerprints can be utilized to fathom the powder dispersion state. • Good polymer-powder interactions in the paste ensure good powder dispersion. • Time-dependent gel-like viscoelastic features are found with optimum silver pastes. • The size and shape of functional powder affect the dispersion and film performances.

  14. Subtle pulmonary nodules: detection and identification with storage phosphor radiographs and conventional chest films

    International Nuclear Information System (INIS)

    Scheck, R.J.; Schaetzl, M.; Kandziora, C.; Panzer, M.; Rienmueller, R.

    1994-01-01

    To determine the value of digital storagephosphor radiography (SR) on the detection and identification of subtle lung nodules, postero-anterior (PA) and lateral (LAT) film-screen (FR) chest radiographs were compared with isodose SR images of 45 patients with metastatic malignancies. The SR postprocessing was done with a particular mode previously optimized for routine chest radiography. Pulmonary metastases were found in 34 patients and were proved or excluded by CT (n=28) or longterm follow-up FR (n=17). Chest images were divided into four regions for evaluation of image quality, number of lung nodules per region and marked pulmonary structures by receiver-operating characteristics (ROC) analysis (45 patients; 125 nodules; 2810 observations; five readers). Of the nodules selected for an ROC study 82% were 0.5-1.0 cm in diameter. Overall image quality was rated better for FR concerning lung fields (PA) and mediastinum/hilum (LAT). More lung-field nodules were detected on FR than on SR chest images. Use of FR was superior to SR in the general identification of nodules (PA chest), especially concerning intermediate and subtle abnormalities, whereas there was no significant difference for LAT chest images. Our results show, that currently FR still has advantages over SR in the detection and identification of subtle lung nodules in routine clinical radiography. (orig.)

  15. A flexible tactile-feedback touch screen using transparent ferroelectric polymer film vibrators

    International Nuclear Information System (INIS)

    Ju, Woo-Eon; Moon, Yong-Ju; Park, Cheon-Ho; Choi, Seung Tae

    2014-01-01

    To provide tactile feedback on flexible touch screens, transparent relaxor ferroelectric polymer film vibrators were designed and fabricated in this study. The film vibrator can be integrated underneath a transparent cover film or glass, and can also produce acoustic waves that cause a tactile sensation on human fingertips. Poly(vinylidene fluoride-trifluoroethylene-chlorotrifluoroethylene) [P(VDF-TrFE-CTFE)] polymer was used as the relaxor ferroelectric polymer because it produces a large strain under applied electric fields, shows a fast response, and has excellent optical transparency. The natural frequency of this tactile-feedback touch screen was designed to be around 200–240 Hz, at which the haptic perception of human fingertips is the most sensitive; therefore, the resonance of the touch screen at its natural frequency provides maximum haptic sensation. A multilayered relaxor ferroelectric polymer film vibrator was also demonstrated to provide the same vibration power at reduced voltage. The flexible P(VDF-TrFE-CTFE) film vibrators developed in this study are expected to provide tactile sensation not only in large-area flat panel displays, but also in flexible displays and touch screens. (papers)

  16. Starch films from a novel (Pachyrhizus ahipa) and conventional sources: Development and characterization

    International Nuclear Information System (INIS)

    López, Olivia V.; García, María A.

    2012-01-01

    Biodegradable films from ahipa, cassava and corn native starches were developed by casting method and their physicochemical, mechanical and barrier properties were analyzed taking into account the different starch botanical sources. Filmogenic suspensions were prepared; their rheological behaviors were studied and all of them exhibited film-forming ability. However, mechanical assays demonstrated that unplasticized films were too rigid, limiting their technological applications. Thus, 1.5% w/w of glycerol as plasticizer was added to filmogenic suspensions and film flexibility and extensibility were improved, this effect was more significant for ahipa and cassava starch films. Furthermore, thickness, moisture content and water solubility of the developed films were increased when plasticizer was incorporated. Glycerol addition reduced film water vapor permeability and the lowest reduction corresponded to cassava starch films due to the high viscosity of its filmogenic suspensions. Plasticized starch films resulted to be UV radiation barriers; ahipa starch films had the lowest light absorption capacity and higher transparency than cassava and corn starch films. Dynamic-mechanical analysis indicated that plasticized films were partially miscible systems exhibiting two relaxations, one attributed to the starch-rich phase and the other to the glycerol-rich one. Likewise, it could be demonstrated that glycerol exerted a major plasticizing effect on ahipa starch matrixes. Highlights: ► Ahipa, cassava and corn starch films were developed by casting method. ► Glycerol effect on film mechanical behavior was major for tuberous starch films. ► Ahipa starch films resulted to be more transparent with lower UV absorption capacity. ► Plasticized films were partially miscible systems: with a glycerol-rich and a starch-rich phase. ► Glycerol exerted a major plasticizing effect on ahipa starch films.

  17. Calibration of screen-type X-ray films for electron beams

    International Nuclear Information System (INIS)

    Kobayashi, T.; Sato, Y.; Yoshida, K.; Tateyama, N.; Komori, Y.; Nakabayashi, T.; Oyamada, M.; Nishimura, J.

    2002-01-01

    In order to extract the maximum performance of the screen-type X-ray film for the detection of cascade showers in emulsion chambers, we examined the effect of the thickness of the phosphor screen by irradiation with 200 MeV electron beams. The observed data is in agreement with our analytical prediction of the radiative transfer of photons in a phosphor screen. If we use a combination of the specially prepared screen, HR16B, with a phosphor layer of 400 μm and a green-sensitive X-ray film, HA30, the detection threshold energy of cascade showers can be considerably lowered down to 140 GeV. (author)

  18. Calibration of screen-type X-ray films for electron beams

    CERN Document Server

    Kobayashi, T; Yoshida, K; Tateyama, N; Komori, Y; Nakabayashi, T; Oyamada, M; Nishimura, J

    2002-01-01

    In order to extract the maximum performance of the screen-type X-ray film for the detection of cascade showers in emulsion chambers, we examined the effect of the thickness of the phosphor screen by irradiation with 200 MeV electron beams. The observed data is in agreement with our analytical prediction of the radiative transfer of photons in a phosphor screen. If we use a combination of the specially prepared screen, HR16B, with a phosphor layer of 400 mu m and a green-sensitive X-ray film, HA30, the detection threshold energy of cascade showers can be considerably lowered down to 140 GeV. (author)

  19. Gastro-duodenal perforations: conventional plain film, US and CT findings in 166 consecutive patients

    International Nuclear Information System (INIS)

    Grassi, Roberto; Romano, Stefania; Pinto, Antonio; Romano, Luigia

    2004-01-01

    Introduction: Gastro-duodenal perforations may be suspected in patients with history of ulceration, who present with acute pain and abdominal wall rigidity, but radiological findings in these cases may be unable to confirm a clinical diagnosis. The aim of our study was to report our experience in the diagnosis of gastro-duodenal perforation by conventional radiography, US and CT examinations. Material and methods: We retrospectively reviewed medical records of 166 consecutive patients who presented in the last 2 years to our institutions with symptoms of acute abdomen and submitted to surgery at the Emergency Unit of the ''A.Cardarelli'' Hospital of Naples with a surgical finding of perforated gastro-duodenal ulcer. The evidence of free intraperitoneal air on abdominal plain film was considered as a direct or suggestive finding of perforation. Evidence of intraperitoneal free fluid and/or reduced intestinal peristalsis at sonographic examination were considered indirect signs of gastro-duodenal perforation. Evidence of free peritoneal gas at CT was considered as a direct evidence of gastro-duodenal perforation. Results: Twenty patients underwent immediate surgery with no preoperative imaging evaluation, in 10 of them the site of perforation was found in a juxta-pyloric region and in the others at level of duodenum. In 146 patients submitted to serial radiological investigations before surgery, the site of perforation was in 56 (38.3%) duodenal, in 52 (35.6%) juxta-pyloric, in 28 (19.1%) gastric and in 10 (6.8%) pyloric. The cause of perforation was in all cases gastric or duodenal ulceration, in seven cases involving pancreatic parenchyma. In 110 (75.4%) patients with direct findings of perforation, in 94 cases (85.5%) the correct diagnosis was established on abdominal plain film, in two (1.8%) with radiographic and sonographic examinations and in 14 (12.7%) on CT findings. In 36 (24,6%) patients with no direct findings of perforation, only 24 (16,4%) of them

  20. Gastro-duodenal perforations: conventional plain film, US and CT findings in 166 consecutive patients

    Energy Technology Data Exchange (ETDEWEB)

    Grassi, Roberto; Romano, Stefania E-mail: stefromano@libero.it; Pinto, Antonio; Romano, Luigia

    2004-04-01

    Introduction: Gastro-duodenal perforations may be suspected in patients with history of ulceration, who present with acute pain and abdominal wall rigidity, but radiological findings in these cases may be unable to confirm a clinical diagnosis. The aim of our study was to report our experience in the diagnosis of gastro-duodenal perforation by conventional radiography, US and CT examinations. Material and methods: We retrospectively reviewed medical records of 166 consecutive patients who presented in the last 2 years to our institutions with symptoms of acute abdomen and submitted to surgery at the Emergency Unit of the ''A.Cardarelli'' Hospital of Naples with a surgical finding of perforated gastro-duodenal ulcer. The evidence of free intraperitoneal air on abdominal plain film was considered as a direct or suggestive finding of perforation. Evidence of intraperitoneal free fluid and/or reduced intestinal peristalsis at sonographic examination were considered indirect signs of gastro-duodenal perforation. Evidence of free peritoneal gas at CT was considered as a direct evidence of gastro-duodenal perforation. Results: Twenty patients underwent immediate surgery with no preoperative imaging evaluation, in 10 of them the site of perforation was found in a juxta-pyloric region and in the others at level of duodenum. In 146 patients submitted to serial radiological investigations before surgery, the site of perforation was in 56 (38.3%) duodenal, in 52 (35.6%) juxta-pyloric, in 28 (19.1%) gastric and in 10 (6.8%) pyloric. The cause of perforation was in all cases gastric or duodenal ulceration, in seven cases involving pancreatic parenchyma. In 110 (75.4%) patients with direct findings of perforation, in 94 cases (85.5%) the correct diagnosis was established on abdominal plain film, in two (1.8%) with radiographic and sonographic examinations and in 14 (12.7%) on CT findings. In 36 (24,6%) patients with no direct findings of perforation, only 24

  1. Sensitometric effects of varying the intensifying screens used with Agfa Dentus ST8G and RP6 panoramic radiographic films.

    Science.gov (United States)

    Wakoh, M; Farman, A G; Scarfe, W C; Kitagawa, H; Kuroyanagi, K

    1997-07-01

    To compare the sensitometric effects and information yield of varying the intensifying screens used with both Dentus ST8G and RP6 Agfa Gevaert, Dormagen, Germany panoramic radiographic films. Four screen-film combinations were employed for each of the two film types. The screens used were blue fluorescing PX-III (Kasei Optonix, Tokyo, Japan) and Special (Siemens AG, Bensheim, Germany), as well as green fluorescing Lanex Regular (Eastman Kodak, Rochester, NY, USA) and Trimax T16 (3M, Mineapolis, Minnesota, USA). The density response for each screen-film combination was evaluated using the characteristic curves generated. Information yield, as determined by the radiographic detection of defects in an aluminium test object, was evaluated by nine observers. The characteristic curves for ST8G were different when green and blue fluorescing screens were used; however, those for RP6 varied little irrespective of the choice of intensifying screens. Observers were able to perceive defects at significantly lower radiation exposures for ST8G combined with green fluorescing screens compared with blue emitting screens. RP6 with all screen combinations provided similar image detail perceptibility at comparable exposures with ST8G with green-fluorescing screens. RP6 is suitable for use with either the spectrally matched blue emitting screens or green-emitting screens. ST8G radiographic film should always be matched to rare earth screens.

  2. Studies Comparing Screen-Film Mammography and Full-Field Digital Mammography in Breast Cancer Screening: Updated Review

    International Nuclear Information System (INIS)

    Skaane, P.

    2009-01-01

    Full-field digital mammography (FFDM) has several potential benefits as compared with screen-film mammography (SFM) in mammography screening. Digital technology also opens for implementation of advanced applications, including computer-aided detection (CAD) and tomosynthesis. Phantom studies and experimental clinical studies have shown that FFDM is equal or slightly superior to SFM for detection and characterization of mammographic abnormalities. Despite obvious advantages, the conversion to digital mammography has been slower than anticipated, and not only due to higher costs. Until very recently, some countries did not even permit the use of digital mammography in breast cancer screening. The reason for this reluctant attitude was concern about lower spatial resolution and about using soft-copy reading. Furthermore, there was a lack of data supporting improved diagnostic accuracy using FFDM in a screening setting, since two pioneer trials both showed nonsignificantly lower cancer detection rate at FFDM. The 10 studies comparing FFDM and SFM in mammography screening published so far have shown divergent and rather conflicting results. Nevertheless, there is a rapid conversion to digital mammography in breast cancer screening in many western countries. The aim of this article is to give an updated review of these studies, discuss the conflicting findings, and draw some conclusions from the results

  3. Bioequivalence study of a new sildenafil 100 mg orodispersible film compared to the conventional film-coated 100 mg tablet administered to healthy male volunteers

    Science.gov (United States)

    Radicioni, Milko; Castiglioni, Chiara; Giori, Andrea; Cupone, Irma; Frangione, Valeria; Rovati, Stefano

    2017-01-01

    A new orodispersible film formulation of the phosphodiesterase type 5 inhibitor, sildenafil, has been developed to examine the advantages of an orally disintegrating film formulation and provide an alternative to the current marketed products for the treatment of erectile dysfunction. The pharmacokinetics of the sildenafil 100 mg orodispersible film (IBSA) was compared to that of the conventional marketed 100 mg film-coated tablet (Viagra®) after single-dose administration to 53 healthy male volunteers (aged 18–51 years) in a randomized, open, two-way crossover bioequivalence study. Each subject received a single oral dose of 100 mg of sildenafil as test or reference formulation administered under fasting conditions at each of the two study periods according to a randomized crossover design. There was a washout interval of ≥7 days between the two administrations of the investigational medicinal products. Blood samples for pharmacokinetic analysis were collected up to 24 h post-dosing. The primary objective was to compare the rate (peak plasma concentration; Cmax) and extent (area under the curve [AUC] from administration to last observed concentration time; AUC0–t) of sildenafil absorption after single-dose administration of test and reference. Secondary endpoints were observed to describe the plasma pharmacokinetic profiles of sildenafil and its metabolite N-desmethyl-sildenafil relative bioavailability and safety profile after single-dose administration. The mean sildenafil and N-desmethyl-sildenafil plasma concentration–time profiles up to 24 h after single-dose administration of sildenafil 100 mg orodispersible film and film-coated tablet were nearly superimposable. The bioequivalence test was fully satisfied for sildenafil and N-desmethyl-sildenafil in terms of rate and extent of bioavailability. Adverse events occurred at similar rates for the two formulations and were of mild-to-moderate severity. The results suggest that the new orodispersible film

  4. Population-based mammography screening: comparison of screen-film and full-field digital mammography with soft-copy reading--Oslo I study.

    Science.gov (United States)

    Skaane, Per; Young, Kari; Skjennald, Arnulf

    2003-12-01

    To compare screen-film and full-field digital mammography with soft-copy reading in a population-based screening program. Full-field digital and screen-film mammography were performed in 3,683 women aged 50-69 years. Two standard views of each breast were acquired with each modality. Images underwent independent double reading with use of a five-point rating scale for probability of cancer. Recall rates and positive predictive values were calculated. Cancer detection rates determined with both modalities were compared by using the McNemar test for paired proportions. Retrospective side-by-side analysis for conspicuity of cancers was performed by an external independent radiologist group with experience in both modalities. In 3,683 cases, 31 cancers were detected. Screen-film mammography depicted 28 (0.76%) malignancies, and full-field digital mammography depicted 23 (0.62%) malignancies. The difference between cancer detection rates was not significant (P =.23). The recall rate for full-field digital mammography (4.6%; 168 of 3,683 cases) was slightly higher than that for screen-film mammography (3.5%; 128 of 3,683 cases). The positive predictive value based on needle biopsy results was 46% for screen-film mammography and 39% for full-field digital mammography. Side-by-side image comparison for cancer conspicuity led to classification of 19 cancers as equal for probability of malignancy, six cancers as slightly better demonstrated at screen-film mammography, and six cancers as slightly better demonstrated at full-field digital mammography. There was no statistically significant difference in cancer detection rate between screen-film and full-field digital mammography. Cancer conspicuity was equal with both modalities. Full-field digital mammography with soft-copy reading is comparable to screen-film mammography in population-based screening.

  5. Experimental study on image quality when using screens in mammography

    International Nuclear Information System (INIS)

    Maurer, H.J.; Goos, F.

    1979-01-01

    1) Different types of screens and X-ray films have been investigated using a Kodak mamma-phantom I.T.O. 745 and compared with conventional non screen industrial film radiography. 2) Dosisreduction by using screens depends on the used film/screen system. It is possible to reach a relation of 1:10. 3) The information depends on type of screen and of type of film. Therefore, it is possible to reach the information of non screen industrial film radiographs. 4) A suitable film/screen system allows without loss of any diagnostic information to replace non screen industrial films needing a high exposure dosis by a film/screen system needing decreased dosis. (orig.) [de

  6. Archaeology on Screen: Representing Archaeology on Film in Serbia

    Directory of Open Access Journals (Sweden)

    Aleksandar Bandović

    2016-02-01

    Full Text Available Reading the popular culture may contribute to the reflexive view on a discipline such as archaeology. Film, as a part of popular culture, frequently unveils the hidden messages, which may be an echo of a discipline or its distorted image in the mirror. Film and archaeology share not only the common origins in the modernity, but also the imaginary spaces where the past and the present meet and intertwine. The subjects treated in films, the contexts in which archaeology appears, speak of the place the discipline holds in the society, reminding us at the same time of all the elements encompassed by the archaeological discourse. On the other hand, if we compare the portraits of the imaginary archaeologists (such as Professor Mihajlo Pavlović, Vera Zarić, with the witnesses of archaeology in Serbia over the 20th century (Nikola Vulić, Dragoslav Srejović, Milutin Garašanin, we shall approach the meeting point between academic and general public, science and the audience, theory and practice. Extraordinary individuals, unemployed dreamers living at the borders of the worlds, charming connoisseurs of the underworlds – these are but some of the qualities ascribed to the discipline by the films. However, these stereotypes do not generate out of the void, they are the consequence of the self-representation. This mystification of the discipline leads us back to the debate on the responsibility and ethics of the social scientists inside the society they live in. Of course, the suggested reading is one of the many possibilities, one of the archaeological interpretations.

  7. Small-Angle X-ray Scattering Screening Complements Conventional Biophysical Analysis

    DEFF Research Database (Denmark)

    Tian, Xinsheng; Langkilde, Annette Eva; Thorolfsson, Matthias

    2014-01-01

    A crucial step in the development of therapeutic monoclonal antibodies is the selection of robust pharmaceutical candidates and screening of efficacious protein formulations to increase the resistance toward physicochemical degradation and aggregation during processing and storage. Here, we intro...... application of extensive SAXS screening in antibody selection, eventual engineering, and formulation development. © 2014 Wiley Periodicals, Inc. and the American Pharmacists Association J Pharm Sci....

  8. Does digital mammography in a decentralized breast cancer screening program lead to screening performance parameters comparable with film-screen mammography?

    International Nuclear Information System (INIS)

    Ongeval, Chantal van; Steen, Andre van; Zanca, Federica; Bosmans, Hilde; Marchal, Guy; Putte, Gretel vande; Limbergen, Erik van

    2010-01-01

    To evaluate if the screening performance parameters of digital mammography (DM) in a decentralized screening organization were comparable with film-screen mammography (FSM). A nationwide screening program was launched in 2001, and since 2005 screening with DM has been allowed. Firstly, the parameters of the three regional screening units (RSUs) that first switched to DM (11,355 women) were compared with the FSM period of the same three RSUs (23,325 women). Secondly, they were compared with the results of the whole central breast unit (CBU). The recall rate (RR) of the DM group in the initial round was 2.64% [2.40% for FSM (p = 0.43)] and in the subsequent round 1.20% [1.58% for FSM (p = 0.03)]. The cancer detection rate (CDR) was 0.59% for DM and 0.64% for FSM (p = 0.56). The percentage of ductal carcinoma in situ was 0.07% for DM and 0.16% for FSM (p = 0.02). The positive predictive value was high in the subsequent rounds (DM 48.00%, FSM 45.93%) and lower in the initial round (DM 24.05%, FSM 24.86%). Compared with the results of the whole CBU, DM showed no significant difference. DM can be introduced in a decentralized screening organization with a high CDR without increasing the RR. (orig.)

  9. High-performance and flexible thermoelectric films by screen printing solution-processed nanoplate crystals.

    Science.gov (United States)

    Varghese, Tony; Hollar, Courtney; Richardson, Joseph; Kempf, Nicholas; Han, Chao; Gamarachchi, Pasindu; Estrada, David; Mehta, Rutvik J; Zhang, Yanliang

    2016-09-12

    Screen printing allows for direct conversion of thermoelectric nanocrystals into flexible energy harvesters and coolers. However, obtaining flexible thermoelectric materials with high figure of merit ZT through printing is an exacting challenge due to the difficulties to synthesize high-performance thermoelectric inks and the poor density and electrical conductivity of the printed films. Here, we demonstrate high-performance flexible films and devices by screen printing bismuth telluride based nanocrystal inks synthesized using a microwave-stimulated wet-chemical method. Thermoelectric films of several tens of microns thickness were screen printed onto a flexible polyimide substrate followed by cold compaction and sintering. The n-type films demonstrate a peak ZT of 0.43 along with superior flexibility, which is among the highest reported ZT values in flexible thermoelectric materials. A flexible thermoelectric device fabricated using the printed films produces a high power density of 4.1 mW/cm(2) with 60 °C temperature difference between the hot side and cold side. The highly scalable and low cost process to fabricate flexible thermoelectric materials and devices demonstrated here opens up many opportunities to transform thermoelectric energy harvesting and cooling applications.

  10. Influence of sintering temperature on screen printed Cu2ZnSnS4 (CZTS) films

    International Nuclear Information System (INIS)

    Wang Yu; Huang Yanhua; Lee, Alex Y.S.; Wang Chiou Fu; Gong Hao

    2012-01-01

    Highlights: ► The influences of sintering temperature on structure and properties of screen printed Cu 2 ZnSnS 4 (CZTS) were investigated. ► It was found that the direct optical band gap increased with increasing the sintering temperature. ► The screen printed CZTS film after sintering at 450 °C had a high photosensitivity (G i − G d )/G d of 14%. ► The hexagonal CuS phase aggregated after sintering at 500 °C and higher temperature. - Abstract: Screen printing is a useful and simple method for coating layers of several solar materials, but care must be taken in preparing stoichiometric CZTS film due to its instability at a high processing temperature and a small chemical potential domain. This paper reports screen printing prepared CZTS films and the influence of sintering temperature on CZTS properties. The thermostability, structural, electronic and optical properties are studied. The direct optical band gap energies of the films vary from 1.39 to 1.60 eV, while the resistivities change from 830 to 6 Ω cm after sintering at different temperatures up to 550 °C. A high photosensitivity of 14% is achieved for the sample sintered at 450 °C. The phenomena observed are also discussed.

  11. Screening of Particle Fever film and Comedy Night

    CERN Multimedia

    Brice, Maximilien

    2014-01-01

    This documentary brings to life the start-up of the world’s most powerful particle accelerator, the LHC, and the two-year-long global effort that led to the discovery of the Higgs boson. The screening will be followed by a discussion with director Mark Levinson, editor Walter Munch and the scientists featured in the documentary. The second part of the evening will see scientists take to the stage as comedians for the Comedy Night.

  12. Humidity sensing properties of WO3 thick film resistor prepared by screen printing technique

    International Nuclear Information System (INIS)

    Garde, Arun S

    2014-01-01

    Highlights: • Polycrystalline WO 3 Thick films are fabricated by screen printing technique. • Monoclinic phases were the majority in formation of films. • The peak at 1643 cm −1 shows stretching vibrations attributed to W-OH of adsorbed H 2 O. • Absorption peaks in the range 879–650 cm −1 are attributed to the stretching W-O-W bonds. • Increase in resistance with decrease in RH when exposed to 20–100% RH. - Abstract: Thick films of tungsten oxide based were prepared using standard screen printing technique. To study the effect of temperature on the thick films were fired at different temperature for 30 min in air atmosphere. The WO 3 thick films were characterized with X-ray diffraction, scanning electron microscopy and EDAX for elemental analysis. The formation of mixed phases of the film together with majority of monoclinic phase was observed. IR spectra confirm the peak at 1643 cm −1 clearly shows stretching vibrations attributed to the W-OH bending vibration mode of the adsorbed water molecules. The absorption peaks in the range 879–650 cm −1 are attributed to the stretching W-O-W bonds (i.e. ν [W-O inter -W]). The peak located at 983 cm −1 belong to W=O terminal of cluster boundaries. A change in the resistance was observed with respect to the relative humidity when the WO 3 thick films were exposed to a wide humidity range of 20–100%. An increasing firing temperature of WO 3 film increases with the sensitivity. The parameters such as sensitivity and hysteresis of the WO 3 film sensors have been evaluated

  13. Application of radiographic magnification technique with an ultra-high-speed rare-earth screen/film system to oral cholecystography

    International Nuclear Information System (INIS)

    Imhof, H.; Doi, K.

    1978-01-01

    2x magnification employing a 200-μ focal spot and an Alpha 8-XM screen/film system was applied to oral cholecystography and the results compared with those for the conventional contact technique with the Par-RP system. The basic imaging properties of the system, as well as phantom studies, indicated that the image quality obtained with magnification is comparable to or better than that for the conventional technique. In clinical studies on the detection of gallstones, the conventional technique revealed 5 true-positive and 17 true-negative cases and 1 false-positive and 2 false-negative cases, while the magnification technique provided 7 true-positive and 18 true-negative cases but no false cases. With the magnification technique the skin dose was reduced to approximately half that for the conventional contact technique

  14. Comparative study of the characteristics of Ni films deposited on SiO2/Si(100) by oblique-angle sputtering and conventional sputtering

    International Nuclear Information System (INIS)

    Yu Mingpeng; Qiu Hong; Chen Xiaobai; Wu Ping; Tian Yue

    2008-01-01

    Ni films were deposited on SiO 2 /Si(100) substrates at 300 K and 573 K by oblique-angle sputtering and conventional sputtering. The films deposited at 300 K mainly have a [110] crystalline orientation in the growing direction whereas those deposited at 573 K grow with a [111] crystalline orientation in the growing direction. The film prepared only at 300 K by oblique-angle sputtering grows with a weakly preferential orientation along the incidence direction of the sputtered Ni atoms. All the films grow with thin columnar grains perpendicular to the substrate surface. The grain size of the films sputter-deposited obliquely is larger than that of the films sputter-deposited conventionally. The grain size of the Ni film does not change markedly with the deposition temperature. The film deposited at 573 K by oblique-angle sputtering has the highest saturation magnetization. For the conventional sputtering, the coercivity of the Ni film deposited at 573 K is larger than that of the film deposited at 300 K. However, for the oblique-angle sputtering, the coercivity of the Ni film is independent of the deposition temperature. All the Ni films exhibit an isotropic magnetization characteristic in the film plane

  15. Photosensitive space charge limited current in screen printed CdTe thin films

    Science.gov (United States)

    Vyas, C. U.; Pataniya, Pratik; Zankat, Chetan K.; Patel, Alkesh B.; Pathak, V. M.; Patel, K. D.; Solanki, G. K.

    2018-05-01

    Group II-VI Compounds have emerged out as most suitable in the class of photo sensitive material. They represent a strong position in terms of their applications in the field of detectors as well as photo voltaic devices. Cadmium telluride is the prime member of this Group, because of high acceptance of this material as active component in opto-electronic devices. In this paper we report preparation and characterization of CdTe thin films by using a most economical screen printing technique in association with sintering at 510°C temperature. Surface morphology and smoothness are prime parameters of any deposited to be used as an active region of devices. Thus, we studied of the screen printed thin film by means of atomic force microscopy (AFM) and scanning electron microscopy (SEM) for this purpose. However, growth processes induced intrinsic defects in fabricated films work as charge traps and affect the conduction process significantly. So the conduction mechanism of deposited CdTe thin film is studied under dark as well as illuminated conditions. It is found that the deposited films showed the space charge limited conduction (SCLC) mechanism and hence various parameters of space charge limited conduction (SCLC) of CdTe film were evaluated and discussed and the photo responsive resistance is also presented in this paper.

  16. Comparison of computerized digital and film-screen radiography: response to variation in imaging kVp

    Energy Technology Data Exchange (ETDEWEB)

    Broderick, N J; Long, B; Dreesen, R G; Cohen, M D; Cory, D A [Riley Hospital for Children, Indiana Univ. School of Medicine, Indianapolis, IN (United States). Dept. of Radiology; Katz, B P; Kalasinski, L A [Regenstreif Inst., Indiana Univ. School of Medicine, Indianapolis, IN (United States). Dept. of Medicine

    1992-09-01

    A controlled prospective study, in an animal model chosen to simulate portable neonatal radiography, was performed to compare the response of the Philips Computed Radiography (CR) system and conventional 200 speed film-screen (FS) to variation in imaging kVp. Acceptable images were obtained on the CR system over a very wide kVp range. In contrast the FS system produced acceptable images over a narrow kVp range. This ability suggests that the CR system should eliminate the need for repeat examinations in cases where a suboptimal kVp setting would have resulted in an unacceptable FS image. CR technology should therefore be ideally suited to portable radiography especially in situations where selection of correct exposure factors is difficult as in the neonatal nursery. (orig.).

  17. Comparison of computerized digital and film-screen radiography: response to variation in imaging kVp

    International Nuclear Information System (INIS)

    Broderick, N.J.; Long, B.; Dreesen, R.G.; Cohen, M.D.; Cory, D.A.; Katz, B.P.; Kalasinski, L.A.

    1992-01-01

    A controlled prospective study, in an animal model chosen to simulate portable neonatal radiography, was performed to compare the response of the Philips Computed Radiography (CR) system and conventional 200 speed film-screen (FS) to variation in imaging kVp. Acceptable images were obtained on the CR system over a very wide kVp range. In contrast the FS system produced acceptable images over a narrow kVp range. This ability suggests that the CR system should eliminate the need for repeat examinations in cases where a suboptimal kVp setting would have resulted in an unacceptable FS image. CR technology should therefore be ideally suited to portable radiography especially in situations where selection of correct exposure factors is difficult as in the neonatal nursery. (orig.)

  18. Scientists Must Not Film but Must Appear on Screen!

    Science.gov (United States)

    Gerdes, A.; Madlener, S.

    2013-12-01

    Film production in science has affected its subjects in a truly remarkable way. Where scientists were once perceived to be poor communicators with an overwhelming aptitude for numbers and figures, audiences now have access to scientists they can understand and even relate to. Over the years, scientists have grown accustomed to involving and using the media in their research and exposing their science to wider audiences, making them better communicators. This is a huge development, and one that is especially noticeable at MARUM, the Center for Marine Environmental Sciences at the University of Bremen/Germany. Over time, the collaboration between the scientists and public relations staff has taught us all to be better at what we do. A unique characteristic of MARUM TV is that more or less all videos are produced 'in house'; we have established the small yet effective infrastructure necessary do develop, execute, and distribute semi-professional videos to access broader audiences and increase world-wide visibility. MARUM TV relies on our research scientists to operate cameras and capture important moments offshore on expedition, and to cooperate with us as we shoot footage of them and conduct interviews onshore in the lab. In turn, we promote their research and help increase their accessibility. At the forefront of our success is the relatively recent implementation of HD cameras on MARUM's fleet of remotely operated vehicles, which capture stunning video footage of the deep sea. Furthermore, sustained collaborations with national tv stations, online media portals, and large production companies helps inform our process and increases MARUM's visibility. The result is an extensive suite of about 70 short and long format science videos with some of the highest view counts on YouTube compared to other marine institutes. In the session PA011 'Scientists must film!' we intent to address issues regarding roadblocks to bridging science and media: a) Science communication

  19. Realization of hexagonal barium ferrite thick films on Si substrates using a screen printing technique

    International Nuclear Information System (INIS)

    Chen Yajie; Smith, Ian; Geiler, Anton L; Vittoria, Carmine; Harris, Vincent G; Zagorodnii, Volodymyr; Celinski, Zbigniew

    2008-01-01

    Hexagonal barium ferrite thick films (50-200 μm) have been deposited on Si and Al 2 O 3 /Si substrates using a screen printing technique. X-ray diffractometry, scanning electron microscopy and magnetometry were used to characterize and correlate the ferrite films' microstructure and magnetic properties. The experiments indicated that an Al 2 O 3 underlayer was effective in preventing silicon diffusion into the barium ferrite films during a final sintering treatment at temperatures above 1100 deg. C. A two-stage sintering process allowed a reasonable tradeoff between mechanical and magnetic properties. This work reveals the feasibility of fabrication of thick ferrite films on large substrates (up to 25 mm in diameter) for future planar microwave devices compatible with semiconductor integrated circuits processing

  20. High-Performance Screen-Printed Thermoelectric Films on Fabrics.

    Science.gov (United States)

    Shin, Sunmi; Kumar, Rajan; Roh, Jong Wook; Ko, Dong-Su; Kim, Hyun-Sik; Kim, Sang Il; Yin, Lu; Schlossberg, Sarah M; Cui, Shuang; You, Jung-Min; Kwon, Soonshin; Zheng, Jianlin; Wang, Joseph; Chen, Renkun

    2017-08-04

    Printing techniques could offer a scalable approach to fabricate thermoelectric (TE) devices on flexible substrates for power generation used in wearable devices and personalized thermo-regulation. However, typical printing processes need a large concentration of binder additives, which often render a detrimental effect on electrical transport of the printed TE layers. Here, we report scalable screen-printing of TE layers on flexible fiber glass fabrics, by rationally optimizing the printing inks consisting of TE particles (p-type Bi 0.5 Sb 1.5 Te 3 or n-type Bi 2 Te 2.7 Se 0.3 ), binders, and organic solvents. We identified a suitable binder additive, methyl cellulose, which offers suitable viscosity for printability at a very small concentration (0.45-0.60 wt.%), thus minimizing its negative impact on electrical transport. Following printing, the binders were subsequently burnt off via sintering and hot pressing. We found that the nanoscale defects left behind after the binder burnt off became effective phonon scattering centers, leading to low lattice thermal conductivity in the printed n-type material. With the high electrical conductivity and low thermal conductivity, the screen-printed TE layers showed high room-temperature ZT values of 0.65 and 0.81 for p-type and n-type, respectively.

  1. Bioequivalence study of a new sildenafil 100 mg orodispersible film compared to the conventional film-coated 100 mg tablet administered to healthy male volunteers

    Directory of Open Access Journals (Sweden)

    Radicioni M

    2017-04-01

    Full Text Available Milko Radicioni,1 Chiara Castiglioni,1 Andrea Giori,2 Irma Cupone,3 Valeria Frangione,4 Stefano Rovati4 1CROSS Research S.A., Phase I Unit, Arzo, Switzerland; 2IBSA Farmaceutici Italia, Lodi, Italy; 3Bouty S.p.A., Strada Padana Superiore, Cassina De’ Pecchi, Italy; 4IBSA Institut Biochimique S.A., Pambio-Noranco, Switzerland Abstract: A new orodispersible film formulation of the phosphodiesterase type 5 inhibitor, sildenafil, has been developed to examine the advantages of an orally disintegrating film formulation and provide an alternative to the current marketed products for the treatment of erectile dysfunction. The pharmacokinetics of the sildenafil 100 mg orodispersible film (IBSA was compared to that of the conventional marketed 100 mg film-coated tablet (Viagra® after single-dose administration to 53 healthy male volunteers (aged 18–51 years in a randomized, open, two-way crossover bioequivalence study. Each subject received a single oral dose of 100 mg of sildenafil as test or reference formulation administered under fasting conditions at each of the two study periods according to a randomized crossover design. There was a washout interval of ≥7 days between the two administrations of the investigational medicinal products. Blood samples for pharmacokinetic analysis were collected up to 24 h post-dosing. The primary objective was to compare the rate (peak plasma concentration; Cmax and extent (area under the curve [AUC] from administration to last observed concentration time; AUC0–t of sildenafil absorption after single-dose administration of test and reference. Secondary endpoints were observed to describe the plasma pharmacokinetic profiles of sildenafil and its metabolite N-desmethyl-sildenafil relative bioavailability and safety profile after single-dose administration. The mean sildenafil and N-desmethyl-sildenafil plasma concentration–time profiles up to 24 h after single-dose administration of sildenafil 100 mg

  2. Physical and Clinical Comparison between a Screen-Film System and a Dual-Side Reading Mammography-Dedicated Computed Radiography System

    International Nuclear Information System (INIS)

    Rivetti, S.; Canossi, B.; Battista, R.; Vetruccio, E.; Torricelli, P.; Lanconelli, N.; Danielli, C.; Borasi, G.

    2009-01-01

    Background: Digital mammography systems, thanks to a physical performance better than conventional screen-film units, have the potential of reducing the dose to patients, without decreasing the diagnostic accuracy. Purpose: To achieve a physical and clinical comparison between two systems: a screen-film plate and a dual-side computed radiography system (CRM; FUJIFILM FCR 5000 MA). Material and Methods: A unique feature of the FCR 5000 MA system is that it has a clear support medium, allowing light emitted during the scanning process to be detected on the 'back' of the storage phosphor plate, considerably improving the system's efficiency. The system's physical performance was tested by means of a quantitative analysis, with calculation of the modulation transfer function, detective quantum efficiency, and contrast-detail analysis; subsequently, the results were compared with those achieved using a screen-film system (SFM; Eastmann Kodak MinR-MinR 2000). A receiver operating characteristic (ROC) analysis was then performed on 120 paired clinical images obtained in a craniocaudal projection with the conventional SFM system under standard exposure conditions and also with the CRM system working with a dose reduced by 35% (average breast thickness: 4.3 cm; mean glandular dose: 1.45 mGy). CRM clinical images were interpreted both in hard copy and in soft copy. Results: The ROC analysis revealed that the performances of the two systems (SFM and CRM with reduced dose) were similar (P>0.05): the diagnostic accuracy of the two systems, when valued in terms of the area underneath the ROC curve, was found to be 0.74 for the SFM, 0.78 for the CRM (hard copy), and 0.79 for the CRM (soft copy). Conclusion: The outcome obtained from our experiments shows that the use of the dual-side CRM system is a very good alternative to the screen-film system

  3. Patient doses and radiation risks in film-screen mammography in Finland

    International Nuclear Information System (INIS)

    Servomaa, A.; Parviainen, T.; Komppa, T.

    1995-01-01

    Screen-film mamography is the most sensitive method for the early detection of breast cancer. Breast doses in mamography should be measured for several reasons, especially for the evaluation of patient risk in a screening programme, but also for the assessment and comparison of imaging techniques and equipment performance. In this study, the factors affecting patient doses were assessed by making performance and patient dose measurements; about 50 mammographic units used for screening were included in the study. The lifetime risk as a function of age at exposure was calculated using the average glandular dose, the relative risk model shown in the BEIR V report, and the breast cancer mortality in Finland. The mean surface dose of a 4.5 cm thick phantom was 6.3 mGy, and the mean glandular dose 1.0 mGy. Analysis of the surface dose with respect to film optical density, relative speed of film processing, sensitivity of image receptors, and antiscatter grid showed that the mean surface dose could be decreased by more than 50%. For the screened age group of 50 to 59 years, the risk of exposure-induced death (REID) of breast cancer is about 1.4 x 10 -6 mSv -1 , and the average loss of life expectancy due to the radiation-induced breast cancer deaths (LLE/REID) is about 9.5 years. (Author)

  4. Simulation study of a capillary film solar still coupled with a conventional solar still in south Algeria

    International Nuclear Information System (INIS)

    Zerrouki, Moussa; Settou, Noureddine; Marif, Yacine; Belhadj, Mohmed Mustapha

    2014-01-01

    Highlights: • Coupling in series a capillary film solar still and a conventional solar still. • Combined heat and mass transfer analyses in solar distillation systems. • Design parameters of the system are optimized by simulation program. - Abstract: This work presents a numerical simulation of capillary film solar still (distiller) coupled in series with another conventional solar still. Different transfer phenomena of heat and mass are considered to evaluate the daily distillate production. The study takes into account the quality of brackish water with moderate salinity in Adrar city (south of Algeria). The performance of the system is evaluated and compared with that of conventional solar still under the same meteorological conditions. A numerical simulation is carried out to appreciate the developed model and to optimize the relationship between both distillers collecting surfaces. The obtained results show that the system daily production is at 54–83% higher than that of the conventional one. In addition, some parameters influences are studied to define the optimal operating conditions for the present system. For the first solar still, the inclination angle and surfaces ratio have a significant effect on distillate production. Brine flow rate and wind speed have slight effect on still production

  5. A review of portal screen-film technology and five radiologists' evaluations of some existing products.

    Science.gov (United States)

    Walker, M A; Steinheimer, D N; Weir, V A; Homco, L D; Green, R W; Morris, E L; Hess, M E

    1999-01-01

    Portal radiographs, radiographs made to document the accuracy of radiotherapy treatment fields, are typically of poor image contrast. Recently, a new portal film and screened-cassette system was marketed, the Kodak EC-L system, with the claim of greatly improved image contrast. This new EC-L system was tested on a canine cadaver exposed to Cobalt-60 teletherapy gamma radiation, and image quality was compared to earlier marketed Kodak portal film products. The EC-L system was found to provide portal images of improved contrast/quality.

  6. Comparison of screen-film combinations: results of a contrast detail study and interactive image quality analysis. Pt. 2. Linear assessment of grey scale ranges with interactive (automatic) image analysis

    International Nuclear Information System (INIS)

    Stamm, G.; Eichbaum, G.; Hagemann, G.

    1997-01-01

    The following three screen-film combinations were compared: (a) A combination of anticross-over film and UV-light emitting screens, (b) a combination of blue-light emitting screens and film, and (c) a conventional green fluorescing screen-film combination. Radiographs of a specially designed plexiglass phantom (0.2x0.2x0.12 m 3 ) with bar patterns of lead and plaster and of air, respectively were obtained using the following parameters: 12 pulse generator, 0.6 mm focus size, 4.7 mm aluminium prefilter, a grid with 40 lines/cm (12:1) and a focus-detector distance of 1.15 m. Image analysis was performed using an IBAS system and a Zeiss Kontron computer. Display conditions were the following: Display distance 0.12 m, a vario film objective 35/70 (Zeiss), a video camera tube with a Pb0 photocathode, 625 lines (Siemens Heimann), an IBAS image matrix of 512x512 pixels with a resolution of 7 lines/mm, the projected matrix area was 5000 μm 2 . Grey scale ranges were measured on a line perpendicular to the grouped bar patterns. The difference between the maximum and minimum density value served as signal. The spatial resolution of the detector system was measured when the signal value was three times higher than the standard deviation of the means of multiple density measurements. The results showed considerable advantages of the two new screen-film combinations as compared to the conventional screen-film combination. The result was contradictory to the findings with pure visual assessment of thresholds (part I) that had found no differences. The authors concluded that (automatic) interactive image analysis algorithms serve as an objective measure and are specifically advantageous when small differences in image quality are to be evaluated. (orig.) [de

  7. Localization and screening in GdNi alloy films

    Energy Technology Data Exchange (ETDEWEB)

    Wu, N.; Dowben, P.A. [Department of Physics and Astronomy, Nebraska Center for Materials and Nanoscience, University of Nebraska-Lincoln, Theodore Jorgenson Hall, 855 North 16th Street, Lincoln, Nebraska 68588-0299 (United States); LaGraffe, D. [Office of Proliferation Detection NA-22, National Nuclear Security Administration, US Department of Energy, 1000 Independence Avenue SW, Washington, DC 20585 (United States); Yakovkin, I.N. [National Academy of Science of Ukraine, Institute of Physics, Prospect Nauki 46, 03028 Kiev (Ukraine)

    2011-05-15

    Gd/Ni compounds with different Gd concentration have been investigated with constant initial state spectroscopy (CIS) of photoemission utilizing the light of synchrotron radiation. The photoemission cross-sections of Gd 5d and 4f states show a strong resonance in CIS spectra at the Gd 5p absorption edge. The screenings of Gd ions by Ni 3d conduction electrons results in a dramatic suppression of the 5p{sup 6}4f{sup 7}5d{sup 1}6s{sup 2} to 5p{sup 5}4f{sup 7}5d{sup 2}6s{sup 2} resonant enhancement of photoemission valence band intensities. This decrease in the super-Coster-Kronig photoemission resonant enhancement of the valence band can be related to the hybridized Gd 5d and Ni 3d bands near the Fermi level, consistent with performed first-principles calculations of local densities of states. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  8. The Gendering of Pastors in Contemporary Nordic Films: Norms, Conventions and Contemporary Views

    Directory of Open Access Journals (Sweden)

    Sofia Sjö

    2015-10-01

    Full Text Available The article examines how Lutheran pastors are gendered in six well-known Nordic films. Building on the theory of mediatisation of religion, the study argues for the need to look at how media shapes religion and gender for a thorough understanding of viewson religion today. The film analyses show a connection between female pastors and less problematised forms of religion, but also traditional ways of undermining women in films. The films are argued to present a problematised religious view on sexuality, mostly connected to male pastors. Both aspects of gendering religion are tied to larger debates and discussions of religion and gender in the Nordic countries today. The article suggests that media have the potential to challenge traditional religious norms and to present their own norms, and highlights the need for further comparative studies.

  9. Novel method for screening of enteric film coatings properties with magnetic resonance imaging.

    Science.gov (United States)

    Dorożyński, Przemysław; Jamróz, Witold; Niwiński, Krzysztof; Kurek, Mateusz; Węglarz, Władysław P; Jachowicz, Renata; Kulinowski, Piotr

    2013-11-18

    The aim of the study is to present the concept of novel method for fast screening of enteric coating compositions properties without the need of preparation of tablets batches for fluid bed coating. Proposed method involves evaluation of enteric coated model tablets in specially designed testing cell with application of MRI technique. The results obtained in the testing cell were compared with results of dissolution studies of mini-tablets coated in fluid bed apparatus. The method could be useful in early stage of formulation development for screening of film coating properties that will shorten and simplify the development works. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Quick screening for new flux pinning materials in YBCO films with the combinatorial-PLD method

    International Nuclear Information System (INIS)

    Yoshimura, T.; Ichino, Y.; Yoshida, Y.; Takai, Y.; Kita, R.; Suzuki, K.; Takeuchi, T.

    2011-01-01

    An effective way to improve the superconducting properties in REBa 2 Cu 3 O y (REBCO) films under a magnetic field is to dope artificial pinning centers (APC). The pinning performance depends on the content of the APC materials. Usually, the optimal APC content is explored by preparing films one at a time from the REBCO target using different APC material content, which is an extremely time-consuming process. The combinatorial-PLD (C-PLD) method allowed us to prepare films that continuously changed in composition across a single substrate. In this study, we used the C-PLD method to prepare BaSnO 3 (BSO)-doped YBCO films. The films were deposited on SrTiO 3 substrate using a fourth-harmonic Nd:YAG laser. From the results of the J c -B curves at 77 K and B//c, the film that contained 3.2 vol.% of BSO exhibited the best pinning performance in this study. We showed that the C-PLD method was efficient for quick screening of the optimal APC content with only one deposition. We also used the C-PLD method to explore new APC materials, and proved that it can quickly evaluate the new APC materials Ba 3 Cu 3 In 4 O 12 and BaTbO 3 .

  11. Dose reduction by x-ray beam filtration in screen-film radiography

    International Nuclear Information System (INIS)

    Koedooder, C.

    1986-01-01

    This thesis describes experimental and theoretical aspects of dose reduction by x-ray beam filtration in screen-film radiography. The thesis deals mainly with dose reduction under the constraint of constant image quality; an analytical approach is chosen. Therefore, part of the thesis deals with the development of an algorithm to calculate patient dose and exposure for different filter materials and different tube load conditions, under the constraint of constant contrast and constant optical density. (Auth.)

  12. [Conventional radiology, digital radiology with photostimulable phosphor, laser digitalization of thoracic radiographic films at the bedside. A comparative study].

    Science.gov (United States)

    Miceli, M; Stamati, R; Burci, P; Guidarelli, G; Sartoni Galloni, S

    1992-10-01

    The bedside chest images obtained with conventional radiology and with "on line" and "off line" digital modalities were compared to evaluate the respective capabilities in visualizing chest anatomical structures. Seventy patients were submitted to bedside chest examinations with a portable unit; both a conventional film and a digital system (PCR Graphics 1, Philips) with photostimulable phosphor imaging plate were fitted in the radiographic cassette. The former was digitized using an "off line" laser beam unit (FD 2000, Dupont); the latter was subsequently postprocessed by modifying contrast, optical density and spatial frequencies. Thus, 4 different viewing modalities were obtained for each examination: a) conventional radiography; b) standard digital radiography; c) postprocessed digital radiography; d) digitized conventional radiography. Detectability rates of chest anatomical structures were analyzed by 4 independent radiologists on the different images and expressed by a score 1-4. The values were always higher with digital modalities than with the conventional one and the differences were statistically significant (Student's t-test modified by Bonferroni). In particular, the greatest difference was found between c) and a) in retrocardiac lung parenchyma and in skeletal structures, in favour of c). Concerning the comparative adequacy of the various digital modalities, higher detectability rates of chest anatomical structures were obtained with c), but also with b), than with d).

  13. Digital versus screen-film mammography: impact of mammographic density and hormone therapy on breast cancer detection.

    Science.gov (United States)

    Chiarelli, Anna M; Prummel, Maegan V; Muradali, Derek; Shumak, Rene S; Majpruz, Vicky; Brown, Patrick; Jiang, Hedy; Done, Susan J; Yaffe, Martin J

    2015-11-01

    Most studies that have examined the effects of mammographic density and hormone therapy use on breast cancer detection have included screen-film mammography. This study further examines this association in post-menopausal women screened by digital mammography. Approved by the University of Toronto Research Ethics Board, this study identified 688,418 women of age 50-74 years screened with digital or screen-film mammography from 2008 to 2009 within the Ontario Breast Screening Program. Of 2993 eligible women with invasive breast cancer, 2450 were contacted and 1421 participated (847 screen-film mammography, 574 digital direct radiography). Mammographic density was measured by study radiologists using the standard BI-RADS classification system and by a computer-assisted method. Information on hormone therapy use was collected by a telephone-administered questionnaire. Logistic regression and two-tailed tests for significance evaluated associations between factors and detection method by mammography type. Women with >75 % radiologist-measured mammographic density compared to those with diagnosed with an interval than screen-detected cancer, with the difference being greater for those screened with screen-film (OR = 6.40, 95 % CI 2.30-17.85) than digital mammography (OR = 2.41, 95 % CI 0.67-8.58) and aged 50-64 years screened with screen-film mammography (OR = 10.86, 95 % CI 2.96-39.57). Recent former hormone therapy users were also at an increased risk of having an interval cancer with the association being significant for women screened with digital mammography (OR = 2.08, 95 % CI 1.17-3.71). Breast screening using digital mammography lowers the risk of having an interval cancer for post-menopausal women aged 50-64 with greater mammographic density.

  14. Comparison of absolute speed of screen-film systems measured in seven institutions

    International Nuclear Information System (INIS)

    Yoshida, Ken-ichi; Murakami, Yasunori; Asahara, Masaki; Nakamura, Satoru; Honda, Mitsugi; Morishita, Junji; Higashida, Yoshiharu; Otsuka, Akiyoshi; Yoshida, Akira.

    1998-01-01

    We compared the differences in absolute speed of four screen-film systems in seven institutions. Four different screens (HR-4, Fuji; Lanex Medium, Kodak; Lanex 250, Kodak; and HR-12, Fuji) combined with super HRS-30 (Fuji) film and a beam quality of 80 kV tube voltage with a 20 mm aluminum filter were employed. Absolute speeds of the HR-4, Lanex Medium, Lanex 250, and HR-12 in combination with super HRS-30 were 1.83 mR -1 , 2.72 mR -1 , 2.79 mR -1 , and 5.35 mR -1 (average of seven institutions), respectively. The variation in speed was about ±10% for the seven institutions. Two factors (film processor and densitometer) affecting absolute speed were analyzed. The absolute speed measured in seven institutions varied ±14% depending on the film processor (development conditions) and ±3% depending on the densitometer employed in each institution. (author)

  15. Characterization of film-converter screens systems for neutron radiography; Caracterizacao de sistemas filme-conversor para radiografia com neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, Marcos Leandro Garcia

    2002-07-01

    In general a good quality radiography is that one able to furnish high contrast and sharp edge images. Technically 'high contrast' means high capability to discern material thickness and 'sharp edges', high resolution power. In the present work the optimal conditions to obtain neutron radiography images by using the following film-converter screen systems, Kodak-AA/Gd vaporated; Kodak-AA/Gd metallic; Kodak-AA/LiF; Min-R/GdS{sub 2}O{sub 4}, have been determined. The irradiations were performed in a radiographic facility which was designed and constructed by the neutron radiography working group and is installed at the beamhole 08 of the IEA-R1 nuclear research reactor of the IPEN-CNEN/SP. In order to determine such conditions, the start point was to evaluate the neutron exposure interval for which the optical contrast is maximal and so quantify the sensitivity or capability to discern material thickness, as well as the spatial resolution achieved in the radiographic image, for these systems. The best results have been obtained for the Kodak-AA/Gd vaporated system which is able to discern, for example, 0,024 cm of lucite, with a maximal resolution of 22{mu}m. The radiography images presently obtained in IPEN-CNEN/SP have similar quality when compared to the ones from several other research centers, around the world, whose making use of the same film-converter screens systems. (author)

  16. Multilayered metal oxide thin film gas sensors obtained by conventional and RF plasma-assisted laser ablation

    International Nuclear Information System (INIS)

    Mitu, B.; Marotta, V.; Orlando, S.

    2006-01-01

    Multilayered thin films of In 2 O 3 and SnO 2 have been deposited by conventional and RF plasma-assisted reactive pulsed laser ablation, with the aim to evaluate their behaviour as toxic gas sensors. The depositions have been carried out by a frequency doubled Nd-YAG laser (λ = 532 nm, τ = 7 ns) on Si(1 0 0) substrates, in O 2 atmosphere. The thin films have been characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM) and electrical resistance measurements. A comparison of the electrical response of the simple (indium oxide, tin oxide) and multilayered oxides to toxic gas (nitric oxide, NO) has been performed. The influence on the structural and electrical properties of the deposition parameters, such as substrate temperature and RF power is reported

  17. Performance of conventional pcr for screening for strongylus vulgaris on horse farms

    DEFF Research Database (Denmark)

    Nielsen, Marianne K.; Wøhlk, Chamilla B.M.; Petersen, Stig L.

      Strongyle parasites are ubiquitous in grazing horses. Of these, the bloodworm Strongylus vulgaris is regarded most pathogenic. Increasing levels of anthelmintic resistance in strongyle parasites has lead to recommendations of decreased treatment intensities, and there is now a pronounced need...... for reliable tools for detection of parasite burdens in general and S. vulgaris in particular. The only method currently available is the larval culture, which is laborious and time-consuming, so veterinary practitioners most often pool samples from several horses together in one culture to save time....... This raises doubts about the reliability of the method. Recently, molecular tools have been developed to detect S. vulgaris in fecal samples. The aim of this study was to compare the performance of a conventional polymerase chain reaction (PCR) assay with the traditional larval culture and furthermore test...

  18. Study on Gas Sensing Performance of In2O3 Thick Film Resistors Prepared by Screen Printing Technique

    Directory of Open Access Journals (Sweden)

    S. C. KULKARNI

    2011-02-01

    Full Text Available Indium Oxide (In2O3 thick films were prepared on alumina substrate by using standard screen printing technique. These films were dried and fired at temperatures between 750 0C to 950 0C for two hours in air atmosphere. The compositional, morphological and structural properties of In2O3 films were performed by Energy Dispersive Spectroscopy (EDX, XRD, and Scanning electron Microscopy respectively. We explore the various gases to study sensing performance of In2O3 thick films. The maximum response was reported to film fired at 750 0C for H2S gas at 150 0C operating temperature.

  19. Has the ThinPrep method of cervical screening maintained its improvement over conventional smears in terms of specimen adequacy?

    LENUS (Irish Health Repository)

    Treacy, A

    2009-04-01

    Liquid-based cytology (LBC) has replaced conventional smear assessment in many centers over recent years. In our laboratory this transfer took place in 1999. At that time we performed a split sample study comparing the conventional method of cervical smear evaluation with the ThinPrep system. This split sample study identified a dramatic improvement in specimen adequacy with LBC. While 11% of conventional preparations were reported as unsatisfactory and almost 9% were reported as suboptimal, evaluation of the same cases using LBC saw this combined figure reduced to 2.3%. AIM: To evaluate whether this dramatic fall in unsatisfactory smears has been maintained with the use of LBC. The database for all smears reported for 2005 (100% LBC) was interrogated. The number of unsatisfactory reports was calculated. The reason for an unsatisfactory report was recorded for each case. The overall unsatisfactory rate was compared with that reported in the 1999 split sample study. A total of 41,312 smear tests were reported in 2005. 1,342 (3.25%) were reported as unsatisfactory. Our findings support the ongoing value of LBC in a routine cervical screening laboratory in terms of continuing to maintain a low rate of unsatisfactory smears.

  20. Safety of type and screen method compared to conventional antiglobulin crossmatch procedures for compatibility testing in Indian setting

    Directory of Open Access Journals (Sweden)

    Chaudhary Rajendra

    2011-01-01

    Full Text Available Background: Over the past 30 years, pretransfusion tests have undergone considerable modification. In 1984, AABB recommended that the full cross match could be replaced by an abbreviated cross match in patients with negative antibody screen. However, before implementation of such a policy, issue regarding safety of T & S needs to be evaluated. Objectives: The aim of pretransfusion testing (PTT is to ensure that enough red blood cells (RBCs in the selected red cell components will survive when transfused. Results and Conclusion: We have, therefore in this study; evaluated safety of T & S procedure for PTT in comparison with conventional test tube cross match. The T & S procedure gave a safety of 91.6%. Also, the usefulness of the T & S was shown through the detection of unexpected antibodies in 0.75% (15 out of 2026 of cases.

  1. Comparison of screen-film and full-field digital mammography in Japanese population-based screening

    International Nuclear Information System (INIS)

    Yamada, Takayuki; Saito, Mioko; Ishibashi, Tadashi

    2004-01-01

    The purpose of this study was to investigate how the greater contrast of full-field digital mammography (FFDM) affects the detection of suspicious lesions in Japanese population-based screening. Screen-film mammography (SFM) and FFDM were performed in 480 women aged 50 years or more. A set of mediolateral oblique views was obtained with each modality. All mammograms were independently double-read. The five-scale category assessment and type of finding using the Breast Imaging Reporting and Data System (BIRADS) nomenclature were given. Intraobserver variance, recall rates, and positive predictive value were calculated. The findings between the two modalities were discordant. κ-values for each reader were 0.619 and 0.385, respectively. Almost half of the microcalcifications were called with both modalities. The detection of masses was less concordant between the readers (27%). The masses were detected more frequently with FFDM (73%). Other findings were only detected with one modality. The recall rate was not significantly different (2.9% with SFM vs. 4.2% with FFDM; p=0.253). The positive predictive value was not significantly different (14% with SFM vs. 10% with FFDM; p=0.69), either. Two patients with breast cancer were detected with both modalities. Recall rates and positive predictive value were not significantly different between SFM and FFDM. Cancers were detected with both modalities. (author)

  2. Development and exploitation of the slit method for the characterization of x-ray screen-film combinations

    International Nuclear Information System (INIS)

    Hoeschen, D.

    1987-01-01

    For the determination of the modulation transfer function (MTF) of screen-film combinations which are used in medical x-ray diagnostics a measuring method has been developed: the screen-film combination is exposed to x-rays behind a thin slit and the modulation transfer function is calculated from the resulting rather broad slit images on the film. After solving many technical and photographic problems, the slit method provides high precision in the MTF determination. The only objection against this method is the necessary high dose variation which has to be provided by the x-ray machine

  3. Comparison of Unsatisfactory Samples from Conventional Smear versus Liquid-Based Cytology in Uterine Cervical Cancer Screening Test

    Directory of Open Access Journals (Sweden)

    Hoiseon Jeong

    2017-05-01

    Full Text Available Background Cervical cytology for uterine cervical cancer screening has transitioned from conventional smear (CS to liquid-based cytology (LBC, which has many advantages. The aim of this study was to compare the proportion of unsatisfactory specimens from CS versus LBC at multiple institutions including general hospitals and commercial laboratories. Methods Each participating institution provided a minimum of 500 Papanicolaou (Pap test results for analysis. Pap tests were classified according to the participating institution (commercial laboratory or general hospital and the processing method (CS, ThinPrep, SurePath, or CellPrep. The causes of unsatisfactory results were classified as technical problems, scant cellularity, or complete obscuring factors. Results A total of 38,956 Pap test results from eight general hospitals and three commercial laboratories were analyzed. The mean unsatisfactory rate of LBC was significantly lower than that of CS (1.26% and 3.31%, p = .018. In the LBC method, samples from general hospitals had lower unsatisfactory rates than those from commercial laboratories (0.65% vs 2.89%, p = .006. The reasons for unsatisfactory results were heterogeneous in CS. On the other hand, 66.2% of unsatisfactory results in LBC were due to the scant cellularity. Conclusions Unsatisfactory rate of cervical cancer screening test results varies according to the institution and the processing method. LBC has a significantly lower unsatisfactory rate than CS.

  4. Digital subtraction cerebral angiography by intraarterial injection: comparison with conventional angiography

    International Nuclear Information System (INIS)

    Brant-Zawadzki, M.; Gould, R.; Norman, D.; Newton, T.H.; Lane, B.

    1983-01-01

    For 4 months, a prototype digital subtraction system was used to obtain images of the cerebral vasculature after intraarterial contrast injections. In 12 instances, the intraarterial injections were recorded with both a digital subtraction unit and conventional direct magnification film-screen system. The digital subtraction and conventional film subtraction images were compared and graded for quality and information content by three skilled observers. In addition, quantitative measurements of contrast-detail performance and spatial resolution were obtained on both the digital system and the screen-film imaging chain. In a clinical setting, both the digital subtraction and conventional film-screen systems provided similar quality images and angiographic information. Contrast-detail curves demonstrated that digital subtraction angiography outperformed conventional film technique for low-contrast objects. Digital subtraction angiography also reduced the time required to obtain the angiogram, markedly reduced film cost, and lowered the contrast agent burden

  5. Use of fluorescent-metal intensifying screens with RT-type films for X-ray radiography using pulse devices

    International Nuclear Information System (INIS)

    Morgovskij, L.Ya.; Khakim'yanov, R.R.

    1985-01-01

    A study was made on characteristics of combination of fluorescent-metal Kyokko SMP-308 (Japan) and RCF (Agfa-Gevert) screens with domestic X-ray RT-1, RT-2, RT-5 films. Pulse X-ray MIRA-3D and NORA devices at 200 kV voltage amplitude in X-ray tube were used as radiation source. Testing was conducted for steel samples of 5-40 mm thickness. Comparative exposures for various film combinations with fluorescent-metal screens, fluorescent VP-2 screens and lead foils of 27 μm thickness were determined at that. It is shown that fluorescent-metal screens can be successfully applied with domestic X-ray technical films. They enable to decrease exposure by one order with insignificant deterioration of sensitivity. It is important for testing of pipeline welds

  6. Film reading in the East Midlands Breast Screening Programme – Are we missing opportunities for earlier diagnosis?

    International Nuclear Information System (INIS)

    Jenkins, J.; Murphy, A.E.; Edmondson-Jones, M.; Sibbering, D.M.; Turnbull, A.E.

    2014-01-01

    Aim: To assess whether there are any significant differences in the film-reading histories of interval or screen-detected cancers, and whether this affects stage at diagnosis. Materials and methods: The rates of screen-detected and interval cancers (overall and by radiological categorization) were observed from 268,067 women screened in the East Midlands Breast Screening Programme over 2004–2007 to assess whether there were differences in incidence based on previous film-reading history. Cancers detected at the subsequent screen and film-reading history were analysed to assess whether this affected stage at diagnosis. Analysis undertaken involved cancer detection rates, confidence intervals, and chi-square tests with Monte Carlo simulation. Results: Rates of interval cancers were similar in all groups where at least one reader had indicated recall to assessment (6.1–7.7/1000) and were significantly higher in comparison to women whose previous film-reading outcome was unanimous routine rescreen (2.9/1000; p < 0.001). Four point one percent of interval cancers with no previous recall outcomes were false negatives, which was significantly lower compared to the groups where at least one reader had indicated recall (10.9%; p = 0.005). Cancers detected at the subsequent screen demonstrated no significant difference in prognosis dependent on previous film-reading history (p = 0.503). Conclusion: The prognosis of screen-detected cancers was similar and few cancers were false negatives regardless of film-reading history at the previous screen

  7. Controlled single-blind clinical evaluation of low-dose mammographic screen: film systems

    International Nuclear Information System (INIS)

    Sickles, E.A.; Genant, H.K.

    1979-01-01

    The ability of five low-dose mammographic screen-film systems to portray normal and abnormal breast structures was evaluated in parallel with a study of physical image properties. Single-blind evaluations of the visibility of normal breast architecture, mass lesions, and calcifications were made on the mammograms of 100 patients radiographed with each of the systems. There was increased noise and slightly poorer resolution of the faster recording systems, but there was no difference in final diagnostic impressions among the five systems. These results suggest that the faster systems will result in substantial dose reduction without sacrificing diagnostic accuracy

  8. Performance characteristics of digital vs film screen mammography in community practice.

    Science.gov (United States)

    Dabbous, Firas; Dolecek, Therese A; Friedewald, Sarah M; Tossas-Milligan, Katherine Y; Macarol, Tere; Summerfelt, Wm Thomas; Rauscher, Garth H

    2018-05-01

    We compared the performance characteristics of 297 629 full field digital (FFDM) and 416 791 screen film mammograms (SFM). Sensitivity increased with age, decreased with breast density, and was lower for more aggressive and lobular tumors. While sensitivity did not differ significantly by modality, specificity was generally 1%-2% points higher for FFDM than for SFM across age and breast density categories. The lower recall rate for FFDM vs SFM in our study may partially explain performance differences by modality. In this large health care organization, modest gains in performance were achieved with the introduction of FFDM as a replacement for SFM. © 2017 Wiley Periodicals, Inc.

  9. Let's Talk About Water: Film Screenings as an Entrée to Water Science

    Science.gov (United States)

    Hooper, R. P.; Lilienfeld, L.; Arrigo, J.

    2011-12-01

    "Let's Talk about Water" is a film symposium designed to bring together experts and the public to talk about the complex water issues facing society. The format of the event is quite simple: a panel of experts and the audience view a water documentary (such as "FLOW", "Liquid Assets", or "Gasland") together and there is an extended moderated discussion period following the film between the panel and the audience. Properly handled, this simple format can be very effective. A film creates a context of subject and language for the discussion--it gets the audience and the panel on the same page. The moderators must actively manage the discussion, both challenging the panelists with follow up questions, asking questions to simplify the language the expert is using, and passing a question among panelists to bring out different points of view. The panelists are provided with the film in advance to view and, most importantly, meet the day before the event to discuss the film. This makes for a much more convivial discussion at the event. We have found that these discussions can easily be sustained for 90 to 120 minutes with active audience participation. This format has been applied at college campuses with a target audience of lower-level undergraduates. Student clubs are engaged to help with publicity before the event and to assist with registration and ushering during the event. Appropriate classes offer extra credit for student attendance to ensure a strong turnout. A Hollywood film ("Chinatown" in southern California, "A Civil Action" in Boston) is shown on campus during the week preceding the event to help advertise the event. The event itself is typically held on a Saturday with a morning screening of the film. The audience is provided with index cards and pencils to write down questions they have about the film. A lunch is provided during which the questions are organized and used to initiate different discussion themes. The discussion begins with points raised by

  10. Eu-emission quenching by electron screening in VO2 thin films

    International Nuclear Information System (INIS)

    Liu, H.; Lysenko, S.; Rua, A.; Vikhnin, V.; Vasquez, O.; Fernandez, F.E.

    2006-01-01

    As a kind of phase transition functional material, Vanadium dioxide (VO 2 ) thin films deposited on fused quartz substrate were fabricated using pulsed laser deposition (PLD) technique. Europium was introduced for structure study. By laser excitation at 526 nm, VO 2 thin film undergoes a reversible and ultrafast phase transition from semiconductor to metallic state, which results in a change of optical properties. In fluorescence measurement, Eu emission was found severely quenched in all as-grown thin films. After annealing the sample in air, a red Eu-emission appeared. The emission spectrum is characterized by a pronounced twin peak, centered at 617 nm ( 5 D - 7 F 2 ), surrounded by a set of broad, but relatively weaker bands (emission from 5 D to 7 F j manifold). The emission lifetime increased when the sample annealed at higher temperature for longer time. Each spectral component is actually a doublet which is the spectral overlap of emissions from Eu 3+ situated in two sites with different configurations. One is a linear h-Eu 3+ -h, where h stands for holes. Another is a right-angle configuration of h-Eu 3+ -h with Eu 3+ in the corner. In as-grown VO 2 film, Eu 3+ ions can either substitute V 4+ , leaving a negative charge around (Eu 3+ -O) - , or substitute V 5+ , leaving two negative charges around (Eu 3+ -O) -- . Due to trapped electrons in a large radius state, it covers Eu 3+ V 4+ -V 5+ complexes. It suggests that the screening by degenerate electronic gas may result in switching off the Eu-related optical response for a wide spectral region, causing emission quenching in VO 2 films

  11. Clinical evaluation of digital radiography based on a large-area cesium iodide-amorphous silicon flat-panel detector compared with screen-film radiography for skeletal system and abdomen

    International Nuclear Information System (INIS)

    Okamura, Terue; Tanaka, Saori; Koyama, Koichi; Norihumi, Nishida; Daikokuya, Hideo; Matsuoka, Toshiyuki; Yamada, Ryusaku; Kishimoto, Kenji; Hatagawa, Masakatsu; Kudoh, Hiroaki

    2002-01-01

    The aim of this clinical study was to compare the image quality of digital radiography using the new digital Bucky system based on a flat-panel detector with that of a conventional screen-film system for the skeletal structure and the abdomen. Fifty patients were examined using digital radiography with a flat-panel detector and screen-film systems, 25 for the skeletal structures and 25 for the abdomen. Six radiologists judged each paired image acquired under the same exposure parameters concerning three observation items for the bone and six items for the abdomen. Digital radiographic images for the bone were evaluated to be similar to screen-film images at the mean of 42.2%, to be superior at 50.2%, and to be inferior at 7.6%. Digital radiographic images for the abdomen were judged to be similar to screen-film images at the mean of 43.4%, superior at 52.4%, and inferior at 4.2%; thus, digital radiographic images were estimated to be either similar as or superior to screen-film images at over 92% for the bone and abdomen. On the statistical analysis, digital radiographic images were also judged to be preferred significantly in the most items for the bone and abdomen. In conclusion, the image quality of digital radiography with a flat-panel detector was superior to that of a screen-film system under the same exposure parameters, suggesting that dose reduction is possible with digital radiography. (orig.)

  12. Histology Verification Demonstrates That Biospectroscopy Analysis of Cervical Cytology Identifies Underlying Disease More Accurately than Conventional Screening: Removing the Confounder of Discordance

    Science.gov (United States)

    Gajjar, Ketan; Ahmadzai, Abdullah A.; Valasoulis, George; Trevisan, Júlio; Founta, Christina; Nasioutziki, Maria; Loufopoulos, Aristotelis; Kyrgiou, Maria; Stasinou, Sofia Melina; Karakitsos, Petros; Paraskevaidis, Evangelos; Da Gama-Rose, Bianca; Martin-Hirsch, Pierre L.; Martin, Francis L.

    2014-01-01

    Background Subjective visual assessment of cervical cytology is flawed, and this can manifest itself by inter- and intra-observer variability resulting ultimately in the degree of discordance in the grading categorisation of samples in screening vs. representative histology. Biospectroscopy methods have been suggested as sensor-based tools that can deliver objective assessments of cytology. However, studies to date have been apparently flawed by a corresponding lack of diagnostic efficiency when samples have previously been classed using cytology screening. This raises the question as to whether categorisation of cervical cytology based on imperfect conventional screening reduces the diagnostic accuracy of biospectroscopy approaches; are these latter methods more accurate and diagnose underlying disease? The purpose of this study was to compare the objective accuracy of infrared (IR) spectroscopy of cervical cytology samples using conventional cytology vs. histology-based categorisation. Methods Within a typical clinical setting, a total of n = 322 liquid-based cytology samples were collected immediately before biopsy. Of these, it was possible to acquire subsequent histology for n = 154. Cytology samples were categorised according to conventional screening methods and subsequently interrogated employing attenuated total reflection Fourier-transform IR (ATR-FTIR) spectroscopy. IR spectra were pre-processed and analysed using linear discriminant analysis. Dunn’s test was applied to identify the differences in spectra. Within the diagnostic categories, histology allowed us to determine the comparative efficiency of conventional screening vs. biospectroscopy to correctly identify either true atypia or underlying disease. Results Conventional cytology-based screening results in poor sensitivity and specificity. IR spectra derived from cervical cytology do not appear to discriminate in a diagnostic fashion when categories were based on conventional screening

  13. Clinical evaluation of mammography using a screen-film system. Pt. 3

    International Nuclear Information System (INIS)

    Wurm, J.; Behrends, E.; Hofmann-Preiss, K.; Paterok, E.M.; Saebel, M.; Weishaar, J.

    1983-01-01

    In a clinical image quality test, the parameter image quality is analysed using the ROC method and on the basis of mammograms already classified by means of histological findings into ''benign'' and ''malignant'' cases. The results of this analysis confirmed those of the first two studies: The screen-film system, due to its almost equally good image quality, achieves a diagnostic accuracy as good as the Definix test film without screen. In addition, the following two parameters have been investigated in this clinical test: Different knowledge and experience of the evaluating experts in the field of mammography, and the learning progress in the course of expert training. The difference in knowledge and experience of the various evaluators becomes apparent in ROC analysis only with an evaluator having much more experience than the others in the field of mammography. The parameter learning progress - as shown by repeating the evaluation after three months of intensive training - does not come forth clear enough in the ROC curves. An analysis of the frequency distribution of the five decision thresholds reveals the approach of the individual evaluator. (orig.) [de

  14. Polymer Film-Based Screening and Isolation of Polylactic Acid (PLA)-Degrading Microorganisms.

    Science.gov (United States)

    Kim, Mi Yeon; Kim, Changman; Moon, Jungheun; Heo, Jinhee; Jung, Sokhee P; Kim, Jung Rae

    2017-02-28

    Polylactic acid (PLA) has been highlighted as an alternative renewable polymer for the replacement of petroleum-based plastic materials, and is considered to be biodegradable. On the other hand, the biodegradation of PLA by terminal degraders, such as microorganisms, requires a lengthy period in the natural environment, and its mechanism is not completely understood. PLA biodegradation studies have been conducted using mainly undefined mixed cultures, but only a few bacterial strains have been isolated and examined. For further characterization of PLA biodegradation, in this study, the PLA-degrading bacteria from digester sludge were isolated and identified using a polymer film-based screening method. The enrichment of sludge on PLA granules was conducted with the serial transference of a subculture into fresh media for 40 days, and the attached biofilm was inoculated on a PLA film on an agar plate. 3D optical microscopy showed that the isolates physically degraded the PLA film due to bacterial degradation. 16S rRNA gene sequencing identified the microbial colonies to be Pseudomonas sp. MYK1 and Bacillus sp. MYK2. The two isolates exhibited significantly higher specific gas production rates from PLA biodegradation compared with that of the initial sludge inoculum.

  15. Study of Microstructural Parameters of Screen Printed ZnO Thick Film Sensors

    Directory of Open Access Journals (Sweden)

    A. V. PATIL

    2010-06-01

    Full Text Available This paper explores the compositional, morphological and structural properties of ZnO thick films prepared by a standard screen printing method and fired between 650 oC to 900 oC for 2 hours in an air atmosphere. The material characterization was done using X-ray energy dispersive analysis (EDX, X-ray diffraction (XRD and a scanning electron microscope (SEM. The deposited films were polycrystalline in nature having the wurtzite (hexagonal structure with a preferred orientation along the (101 plane. The result shows that the wt. % of Zn was found to be 80.39, 82.66 and 83.47 % for firing temperatures of 700, 800 and 900 oC respectively may be due to the release of excess oxygen. The effect of the firing temperature on structural parameters such as the crystallite size, specific surface area, texture coefficient, RMSmicrostrain, dislocation density and stacking fault probability have been studied. The results indicate that grain growth can be increased by increasing the firing temperature which is responsible for decreasing the RMSmicrostrain, stacking fault probability and dislocation density in ZnO thick films. The crystallite size changes from 18.58 nm to 37.23 nm with respect to the increase in the firing temperature.

  16. A case study comparing the use of laser induced fluorescence with cone penetrometer testing to more conventional screening methods

    International Nuclear Information System (INIS)

    Earley, K.; Rapp, K.

    1995-01-01

    Site assessments utilizing in-situ techniques to characterize subsurface stratigraphy and contaminant distribution are becoming more accepted and commonly used. Laser Induced Fluorescence (LIF) spectroscopy with Cone Penetrometer Test (CPT) is a new technology that provides real-time data on stratigraphy and petroleum hydrocarbons (PHCs) in the subsurface environment. Over the last two years, LIF technological advances have led to field equipment with improved durability, reduced bulk and weight, and the ability to integrate LIF systems with CPT equipment. The Rapid Optical Screening Tool (a Unisys registered trademark hereafter referred to as ROST) presents the development of an in-situ data collection system which couples state-of-the-art LIF technology with CPT. ROST/CPT technology has recently been utilized in a variety of field and soil conditions. These advances, along with the need for rapid in-situ information on the horizontal and vertical distribution of petroleum hydrocarbons (PHCs) have resulted in equipment that is now available for commercial applications. This paper presents a comparison of ROST/CPT to more conventional characterization methods at a manufacturing site in Nebraska. Various PHCs were stored in underground and above ground storage tanks across the site. One of these PHC spill areas consisting of a mixture of diesel fuel oil and kerosene was selected for a comparative study between various site assessment methods

  17. Influence of Pore Size on the Optical and Electrical Properties of Screen Printed TiO2 Thin Films

    Directory of Open Access Journals (Sweden)

    Dinfa Luka Domtau

    2016-01-01

    Full Text Available Influence of pore size on the optical and electrical properties of TiO2 thin films was studied. TiO2 thin films with different weight percentages (wt% of carbon black were deposited by screen printing method on fluorine doped tin oxide (FTO coated on glass substrate. Carbon black decomposed on annealing and artificial pores were created in the films. All the films were 3.2 µm thick as measured by a surface profiler. UV-VIS-NIR spectrophotometer was used to study transmittance and reflectance spectra of the films in the photon wavelength of 300–900 nm while absorbance was studied in the range of 350–900 nm. Band gaps and refractive index of the films were studied using the spectra. Reflectance, absorbance, and refractive index were found to increase with concentrations of carbon black. There was no significant variation in band gaps of films with change in carbon black concentrations. Transmittance reduced as the concentration of carbon black in TiO2 increased (i.e., increase in pore size. Currents and voltages (I-V characteristics of the films were measured by a 4-point probe. Resistivity (ρ and conductivity (σ of the films were computed from the I-V values. It was observed that resistivity increased with carbon black concentrations while conductivity decreased as the pore size of the films increased.

  18. Rod-coating: towards large-area fabrication of uniform reduced graphene oxide films for flexible touch screens.

    Science.gov (United States)

    Wang, Jie; Liang, Minghui; Fang, Yan; Qiu, Tengfei; Zhang, Jin; Zhi, Linjie

    2012-06-05

    A novel strategy is developed for the large-scale fabrication of reduced graphene oxide films directly on flexible substrates in a controlled manner by the combination of a rod-coating technique and room-temperature reduction of graphene oxide. The as-prepared films display excellent uniformity, good transparency and conductivity, and great flexibility in a touch screen. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Measurement of the secondary electron emission from CVD diamond films using phosphor screen detectors

    Science.gov (United States)

    Vaz, R.; May, P. W.; Fox, N. A.; Harwood, C. J.; Chatterjee, V.; Smith, J. A.; Horsfield, C. J.; Lapington, J. S.; Osbourne, S.

    2015-03-01

    Diamond-based photomultipliers have the potential to provide a significant improvement over existing devices due to diamond's high secondary electron yield and narrow energy distribution of secondary electrons which improves energy resolution creating extremely fast response times. In this paper we describe an experimental apparatus designed to study secondary electron emission from diamond membranes only 400 nm thick, observed in reflection and transmission configurations. The setup consists of a system of calibrated P22 green phosphor screens acting as radiation converters which are used in combination with photomultiplier tubes to acquire secondary emission yield data from the diamond samples. The superior signal voltage sampling of the phosphor screen setup compared with traditional Faraday Cup detection allows the variation in the secondary electron yield across the sample to be visualised, allowing spatial distributions to be obtained. Preliminary reflection and transmission yield data are presented as a function of primary electron energy for selected CVD diamond films and membranes. Reflection data were also obtained from the same sample set using a Faraday Cup detector setup. In general, the curves for secondary electron yield versus primary energy for both measurement setups were comparable. On average a 15-20% lower signal was recorded on our setup compared to the Faraday Cup, which was attributed to the lower photoluminescent efficiency of the P22 phosphor screens when operated at sub-kilovolt bias voltages.

  20. H and D curves of screen--film systems: factors affecting their dependence on x-ray energy

    International Nuclear Information System (INIS)

    Vyborny, C.J.

    1979-01-01

    The sensitometric properties of radiographic screen--film systems are investigated with regard to their dependence on x-ray energy. Sensitometric measurements and a heuristic model for density formation are used to show that variation in the relative amount of light emitted by front and back screens may be the most important factor influencing the change in system H and D curves with x-ray energy

  1. Electrical and Gas Sensing Properties of SnO2 Thick Film Resistors Prepared by Screen-printing Method

    Directory of Open Access Journals (Sweden)

    R. Y. BORSE

    2008-10-01

    Full Text Available Thick films of tin-oxide (SnO2 were deposited on alumina substrates employing screen-printing technique. The films were dried and fired at 680 0C for 30 minutes. The variation of D.C. resistance of thick films was measured in air as well as in H2S gas atmosphere as a function of temperature. The SnO2 films exhibit semiconducting behaviour. The SnO2 thick films studied were also showing decrease in resistance with increase of concentration of H2S gas. The film resistors showed the highest sensitivity to H2S gas at 350 0C. The XRD studies of the thick film indicate the presence of different phases of SnO2. The elemental analysis was confirmed by EDX spectra. The surface morphological study of the films was analyzed by SEM. The microstructure of the films was porous resulting from loosely interconnected small crystallites. The parameters such as grain size, activation energy, sensitivity and response time were described.

  2. Soviet Feature Cinema in the Mirror of the Soviet Film Critics (on the Example of Annuals "Screen" (1964-1990

    Directory of Open Access Journals (Sweden)

    AlexanderFedorov

    2016-07-01

    Full Text Available In mid-1960s Moscow publishing house “Art” released yearbooks “Screen”, which reflected in concentrated form the most the important cinematic events in the USSR and the world. The first collection of this kind ("Screen 1964" was printed edition of 45,500 copies. The circulation of the next two collections was 30-35 thousand copies. From 1968 to 1985 the "Screens" were annually with a circulation of 50 thousand copies. "Screen 1987"’s circulation has been increased to 75 thousand, but the rest of the collection issues have returned to the circulation of 50 thousand copies. Each book is illustrated with black-and-white frames of the movies and photos masters of the screen. Yearbooks "Screen" became a sort of mirror of the Soviet critics of the 1960s–1980s, reflecting its ups and downs, forced to default figures, ideological passages, thaw and perestroika hope. From the time of the last annual output has been more than a quarter century. The film history faculty of VGIK has lost its former magic among students. Russian film critic since changed significantly. And compared to thaw and perestroika times – not always in the best possible way. There was, for example, glamorous and glossy film critic, but often superficial film critic dashing Internet users. Many of the authors of the annual "Screen" for a long time are no longer alive. Some of the critics have gone into other professions... But life goes on, and the Russian film critic still be able to delight true fans of the "tenth muse" deep intelligence and evidence-based reasoning.

  3. Thermoelectric properties of P-type Sb2Te3 thick film processed by a screen-printing technique and a subsequent annealing process

    International Nuclear Information System (INIS)

    Kim, Sun Jin; We, Ju Hyung; Kim, Jin Sang; Kim, Gyung Soo; Cho, Byung Jin

    2014-01-01

    Highlights: • We report on thermoelectric properties of screen-printed Sb 2 Te 3 thick film. • Subsequent annealing process determines thermoelectric properties of Sb 2 Te 3 film. • Annealing in tellurium powder ambient contributes to tellurium-rich Sb 2 Te 3 film. • Annealing in tellurium powder ambient enhances carrier mobility of Sb 2 Te 3 film. -- Abstract: We herein report the thermoelectric properties of Sb 2 Te 3 thick film fabricated by a screen-printing technique and a subsequent annealing process. Each step of the screen-printing fabrication process of Sb 2 Te 3 thick film is described in detail. It was found that the subsequent annealing process must be carefully designed to achieve good thermoelectric properties of the screen-printed film. The results show that the annealing of the screen-printed Sb 2 Te 3 thick film together with tellurium powder in the same process chamber significantly improves the carrier mobility by increasing the average scattering time of the carrier in the film, resulting in a large improvement of the power factor. By optimizing the annealing process, we achieved a maximum thermoelectric figure-of-merit, ZT, of 0.32 at room temperature, which is slightly higher than that of bulk Sb 2 Te 3 . Because screen-printing is a simple and low-cost process and given that it is easy to scale up to large sizes, this result will be useful for the realization of large, film-type thermoelectric devices

  4. Reduction of the scattered radiation during X-ray examination with screen-film systems

    Energy Technology Data Exchange (ETDEWEB)

    Vasiliev, V N; Stavitsky, R V [Moscow Research Inst. for Roentgenology and Radiology, Moscow (Russian Federation); Oshomkov, Yu V [Mosroentgen, Moscow Region (Russian Federation)

    1993-01-01

    In diagnostic radiography, during X-ray examination, photons scattered in the patient's body are detected by the intensifying screen and decrease the image contrast. A conventional way to avoid this image degradation is to attenuate the scattered radiation by an antiscatter grid placed between the patient's body and the screen. A grid selectivity effect originates from the greater attenuation of scattered as opposed to primary radiation. Previous authors calculated the primary and scattered radiation transmission factor of photons with initial energy 30-120 keV for a number of typical grids. The primary radiation transmission factor varied from 0.34 to 0.67 and the secondary radiation factor was equal from 0.03 to 0.13. This effect results in a contrast improvement from 2 to 6, but the patient exposure increases up to a factor of 10. In this work we studied the possibility of improving the image contrast by attenuating the scattered radiation by a secondary filter placed between the patient's body and the screen and made of an appropriate material. A selectivity effect due to the secondary filter arises from two circumstances. First, tilting incidence of the scattered radiation results in the path inside the filter being greater than the primary one. Second, the average energy of the scattered radiation is less than the primary and, hence, the attenuation coefficient is greater. (author).

  5. Conventional and right-sided screening for subcutaneous ICD in a population with congenital heart disease at high risk of sudden cardiac death.

    Science.gov (United States)

    Alonso, Pau; Osca, Joaquín; Rueda, Joaquín; Cano, Oscar; Pimenta, Pedro; Andres, Ana; Sancho, María José; Martinez, Luis

    2017-11-01

    Information regarding suitability for subcutaneous defibrillator (sICD) implantation in tetralogy of Fallot (ToF) and systemic right ventricle is scarce and needs to be further explored. The main objective of our study was to determine the proportion of patients with ToF and systemic right ventricle eligible for sICD with both, standard and right-sided screening methods. Secondary objectives were: (i) to study sICD eligibility specifically in patients at high risk of sudden cardiac death, (ii) to identify independent predictors for sICD eligibility, and (iii) to compare the proportion of eligible patients in a nonselected ICD population. We recruited 102 patients with ToF, 33 with systemic right ventricle, and 40 consecutive nonselected patients. Conventional electrocardiographic screening was performed as usual. Right-sided alternative screening was studied by positioning the left-arm and right-arm electrodes 1 cm right lateral of the xiphoid midline. The Boston Scientific ECG screening tool was utilized. In high-risk patients with ToF, eligibility was higher with right-sided screening in comparison with standard screening (61% vs. 44%; p = .018). Eligibility in high-risk right ventricle population was identical with both screening methods (77%, p = ns). The only independent predictor for sICD eligibility was QRS duration. In high-risk patients with ToF, right-sided implantation of the sICD could be an alternative to a conventional ICD. In patients with a systemic right ventricle, implantation of a sICD is an alternative to a conventional sICD. © 2017 Wiley Periodicals, Inc.

  6. Flexible screen printed thick film thermoelectric generator with reduced material resistivity

    International Nuclear Information System (INIS)

    Cao, Z; Koukharenko, E; Torah, R N; Tudor, J; Beeby, S P

    2014-01-01

    This work presents a flexible thick-film Bismuth Tellurium/Antimony Tellurium (BiTe/SbTe) thermoelectric generator (TEG) with reduced material resistivity fabricated by screen printing technology. Cold isostatic pressing (CIP) was introduced to lower the resistivity of the printed thermoelectric materials. The Seebeck coefficient (α) and the resistivity (ρ) of printed materials were measured as a function of applied pressure. A prototype TEG with 8 thermocouples was fabricated on flexible polyimide substrate. The dimension of a single printed element was 20 mm × 2 mm × 78.4 pm. The coiled-up prototype produced a voltage of 36.4 mV and a maximum power of 40.3 nW from a temperature gradient of 20 °C

  7. Film-screen vs. digital radiography in rheumatoid arthritis of the hand. An ROC analysis

    International Nuclear Information System (INIS)

    Jonsson, A.; Borg, A.; Hannesson, P.; Herrlin, K.; Jonsson, K.; Sloth, M.; Pettersson, H.

    1994-01-01

    In a prospective investigation the diagnostic accuracy of filmscreen and digital radiography in rheumatoid arthritis of hands was compared. Seventy hands of 36 patients with established rheumatoid arthritis were included in the study. Each of 11 joints in every hand was evaluated regarding the following radiologic parameters: soft tissue swelling, joint space narrowing, erosions and periarticular osteopenia. The digital images were obtained with storage phosphor image plates and evaluated in 2 forms; as digital hard-copy on film and on a monitor of an interactive workstation. The digital images had a resolution of either 3.33 or 5.0 lp/mm. ROC curves were constructed and comparing the area under the curves no significant difference was found between the 3 different imaging forms in either resolution group for soft tissue swelling, joint space narrowing and erosions. The film-screen image evaluation of periarticular osteopenia was significantly better than the digital hard-copy one in the 3.33 lp/mm resolution group, but no significant difference was found in the 5.0 lp/mm group. These results support the view that currently available digital systems are capable of adequate diagnostic performance. (orig.)

  8. Structural, optical and gas sensing properties of screen-printed nanostructured Sr-doped SnO2 thick film sensor

    International Nuclear Information System (INIS)

    Shaikh, F.I.; Chikhale, L.P.; Patil, J.Y.; Rajgure, A.V.; Suryavanshi, S.S.; Mulla, I.S.

    2013-01-01

    The nanocrystalline materials of strontium doped tin oxide powders were synthesized by conventional co-precipitation method. Synthesized nanophase SnO 2 powders were used to fabricate thick films of pure and Sr-doped SnO 2 using screen-printing technology and investigated for their gas sensing properties towards LPG, ethanol, ammonia and acetone vapor. The crystal structure and phase of the sintered powders were characterized by X-ray diffractometer (XRD) and microstructure by scanning electron microscopy (SEM). All the doped and undoped SnO 2 compositions revealed single phase and solid solution formation. X-ray diffractometer (XRD) results indicated that well crystallized Sr-doped SnO 2 particles of size about 10 nm were obtained at sintering temperature 700℃. The optical properties viz. UV-Vis, FTIR and Raman were used to characterize various physico-chemical properties of samples. The reduction of grain size in metal oxide is a key factor to enhance the gas sensing properties. The doping of Sr in SnO 2 has reduced the grain size and improved the gas response. The results of gas sensing measurements showed that the thick films deposited on alumina substrates using screen-printing technique exhibited high gas response, quick response time and fast recovery time to acetone gas at a working temperature of 250℃. Further, the selectivity of sensor towards acetone with respect to other reducing gases (LPG, ethanol, ammonia) was studied. (author)

  9. Processing parameters for ZnO-based thick film varistors obtained by screen printing

    Directory of Open Access Journals (Sweden)

    de la Rubia, M. A.

    2006-06-01

    Full Text Available Thick film varistors based on the ZnO-Bi2O3-Sb2O3 system have been prepared by screen printing on dense alumina substrates. Different processing parameters like the paste viscosity, burn out and sintering cycles, green and sintered thickness, have been studied to improve the processing of ZnO-based thick film varistors. Starting powders were pre-treated in two different ways in order to control both the Bi-rich liquid phase formation and the excessive volatilization of Bi2O3 during sintering due to the high area/volume ratio of the thick films. Significant changes have been observed in the electrical properties related to the different firing schedule and selection of the starting powders.

    Se han preparado varistores basados en el sistema ZnO-Bi2O3-Sb2O3 en forma de lámina gruesa sobre sustratos de alúmina densa. Diferentes parámetros del procesamiento como la viscosidad de la pasta, los ciclos de calcinación y sinterización y el espesor en verde y sinterizado han sido estudiados para mejorar el procesamiento de los varistores basados en ZnO preparados en forma de lámina gruesa. Los polvos de partida fueron pretratados de dos formas diferentes con el objetivo de controlar la formación de la fase líquida rica en bismuto y la excesiva volatilización de Bi2O3 durante la sinterización debida a la alta relación área-volumen de las láminas gruesas. Se han observado cambios significativos en las propiedades eléctricas relacionadas con los diferentes ciclos de calcinado y con la selección de los polvos de partida.

  10. Interobserver agreement and performance score comparison in quality control using a breast phantom: screen-film mammography vs computed radiography

    International Nuclear Information System (INIS)

    Shimamoto, Kazuhiro; Ikeda, Mitsuru; Satake, Hiroko; Ishigaki, Satoko; Sawaki, Akiko; Ishigaki, Takeo

    2002-01-01

    Our objective was to evaluate interobserver agreement and to compare the performance score in quality control of screen-film mammography and computed radiography (CR) using a breast phantom. Eleven radiologists interpreted a breast phantom image (CIRS model X) by four viewing methods: (a) original screen-film; (b) soft-copy reading of the digitized film image; (c) hard-copy reading of CR using an imaging plate; and (d) soft-copy reading of CR. For the soft-copy reading, a 17-in. CRT monitor (1024 x 1536 x 8 bits) was used. The phantom image was evaluated using a scoring system outlined in the instruction manual, and observers judged each object using a three-point rating scale: (a) clearly seen; (b) barely seen; and (c) not seen. For statistical analysis, the kappa statistic was employed. For ''mass'' depiction, interobserver agreement using CR was significantly lower than when using screen-film (p<0.05). There was no significant difference in the kappa value for detecting ''microcalcification''; however, the performance score of ''microcalcification'' on CR hard-copy was significantly lower than on the other three viewing methods (p<0.05). Viewing methods (film or CR, soft-copy or hard-copy) could affect how the phantom image is judged. Paying special attention to viewing conditions is recommended for quality control of CR mammograms. (orig.)

  11. Varying the Narration Presentation Format and On-Screen Character-Narrator Relationship in an Instructional Science Film.

    Science.gov (United States)

    Sherman, Greg

    This study examined how learning, attitudes, and mental efforts are affected by changing the verbal information presentation format and relationship between the narrator and on-screen character in a junior high school-level science film. Twenty seventh-grade science classes (N=441) were randomly assigned to one of five treatment groups. Each class…

  12. Comparison of conventional Papanicolaou smear and SurePath® liquid-based cytology in the Copenhagen population screening programme for cervical cancer

    DEFF Research Database (Denmark)

    Kirschner, Benny; Simonsen, Kåre; Junge, Jette

    2006-01-01

    OBJECTIVE: To compare diagnostic performance of conventional Papanicolaou smear with SurePath liquid-based cytology in a population screening programme. METHODS: A retrospective comparison was performed on data from two 18-month periods of the screening programme for cervical cancer in the munici......OBJECTIVE: To compare diagnostic performance of conventional Papanicolaou smear with SurePath liquid-based cytology in a population screening programme. METHODS: A retrospective comparison was performed on data from two 18-month periods of the screening programme for cervical cancer...... in the municipality of Copenhagen with conventional Papanicolaou technique (n = 82,116) and liquid-based cytology (n = 84,414). RESULTS: After the conversion to liquid-based cytology the percentage of unsatisfactory samples decreased from 2.3% to 0.3% (P ...-based technique. CONCLUSIONS: This study showed the number of unsatisfactory samples to be significantly reduced with the liquid-based technique. The data suggest that there is an increased detection rate of cervical precancerous lesions with liquid-based cytology, but the number of false positive tests is still...

  13. Screen-printed carbon electrode modified on its surface with amorphous carbon nitride thin film: Electrochemical and morphological study

    Energy Technology Data Exchange (ETDEWEB)

    Ghamouss, F. [Universite de Nantes, UMR 6006-CNRS, FR-2465-CNRS, Laboratoire d' Analyse isotopique et Electrochimique de Metabolismes (LAIEM) (France); Tessier, P.-Y. [Universite de Nantes, UMR CNRS 6502, Institut des Materiaux Jean Rouxel - IMN Faculte des Sciences and des Techniques de Nantes, 2 rue de la Houssiniere, 44322 Nantes Cedex 3 (France); Djouadi, A. [Universite de Nantes, UMR CNRS 6502, Institut des Materiaux Jean Rouxel - IMN Faculte des Sciences and des Techniques de Nantes, 2 rue de la Houssiniere, 44322 Nantes Cedex 3 (France); Besland, M.-P. [Universite de Nantes, UMR CNRS 6502, Institut des Materiaux Jean Rouxel - IMN Faculte des Sciences and des Techniques de Nantes, 2 rue de la Houssiniere, 44322 Nantes Cedex 3 (France); Boujtita, M. [Universite de Nantes, UMR 6006-CNRS, FR-2465-CNRS, Laboratoire d' Analyse isotopique et Electrochimique de Metabolismes (LAIEM) (France)]. E-mail: mohammed.boujtita@univ-nantes.fr

    2007-04-20

    The surface of a screen-printed carbon electrode (SPCE) was modified by using amorphous carbon nitride (a-CN {sub x}) thin film deposited by reactive magnetron sputtering. Scanning electron microscopy and photoelectron spectroscopy measurements were used to characterise respectively the morphology and the chemical structure of the a-CN {sub x} modified electrodes. The incorporation of nitrogen in the amorphous carbon network was demonstrated by X ray photoelectron spectroscopy. The a-CN {sub x} layers were deposited on both carbon screen-printed electrode (SPCE) and silicon (Si) substrates. A comparative study showed that the nature of substrate, i.e. SPCE and Si, has a significant effect on both the surface morphology of deposited a-CN {sub x} film and their electrochemical properties. The improvement of the electrochemical reactivity of SPCE after a-CN {sub x} film deposition was highlighted both by comparing the shapes of voltammograms and calculating the apparent heterogeneous electron transfer rate constant.

  14. Modular high-throughput test stand for versatile screening of thin-film materials libraries

    International Nuclear Information System (INIS)

    Thienhaus, Sigurd; Hamann, Sven; Ludwig, Alfred

    2011-01-01

    Versatile high-throughput characterization tools are required for the development of new materials using combinatorial techniques. Here, we describe a modular, high-throughput test stand for the screening of thin-film materials libraries, which can carry out automated electrical, magnetic and magnetoresistance measurements in the temperature range of −40 to 300 °C. As a proof of concept, we measured the temperature-dependent resistance of Fe–Pd–Mn ferromagnetic shape-memory alloy materials libraries, revealing reversible martensitic transformations and the associated transformation temperatures. Magneto-optical screening measurements of a materials library identify ferromagnetic samples, whereas resistivity maps support the discovery of new phases. A distance sensor in the same setup allows stress measurements in materials libraries deposited on cantilever arrays. A combination of these methods offers a fast and reliable high-throughput characterization technology for searching for new materials. Using this approach, a composition region has been identified in the Fe–Pd–Mn system that combines ferromagnetism and martensitic transformation.

  15. Comparison of interferon {gamma} release assays and conventional screening tests before tumour necrosis factor {alpha} blockade in patients with inflammatory arthritis.

    LENUS (Irish Health Repository)

    Martin, J

    2012-02-01

    OBJECTIVE: To compare the performance of two interferon gamma release assays (IGRAs) and conventional screening tests in patients with inflammatory arthritis undergoing screening for latent tuberculosis infection (LTBI) before treatment with anti-tumour necrosis factor alpha (anti-TNFalpha) compounds. METHODS: Successive patients were subjected to conventional LTBI screening, including a tuberculin skin test (TST). The T-SPOT.TB test was performed on all patients and the QuantiFERON-TB Gold test was performed on a large subset. The results of the IGRAs were compared with the results of conventional screening tests. RESULTS: A total 150 patients were evaluated. The majority (57.9%) had rheumatoid arthritis. Previous vaccination with Bacille Calmette-Guerin was confirmed in 82% of patients. No patient had received prior anti-TB treatment. A total of 57 patients (38.0%) had at least one positive conventional risk factor. In contrast, an unequivocally positive T-SPOT.TB test was seen in only 14\\/143 (9.8%). There was 98.2% agreement between the two IGRAs. Statistically significant associations were found between each of the IGRAs and both TST and risk history, but not chest x-ray (CXR). A positive IGRA result was significantly associated with increased age. TB was not reactivated in any patient during the follow-up period. Interpretation: This study suggests that IGRAs may be useful when screening for LTBI before anti-TNFalpha therapy in patients with immune-mediated inflammatory diseases. The observations reported here also highlight the inadequate performance of CXR as a marker of LTBI.

  16. UV-screening, transparency and water barrier properties of semi refined iota carrageenan packaging film incorporated with ZnO nanoparticles

    Science.gov (United States)

    Khoirunnisa, Assifa Rahma; Joni, I. Made; Panatarani, Camellia; Rochima, Emma; Praseptiangga, Danar

    2018-02-01

    This study aims to develop film for food packaging application with high UV-screening, transparency and water barrier properties. Semi refined iota carrageenan (SRiC) nanocomposite films prepared by addition of zinc oxide (ZnO) nanoparticles as nanofiller using solution casting method. The effect of nanofiller with different concentration (0%, 0.5%, 1.0%, 1.5% w/w carrageenan) on UV-screening, transparency and water barrier properties of films were tested. The water barrier properties of the films were studied by measuring water vapor permeability (WVP) and the optical properties of the films were studied by using UV-Vis spectrophotometer at 280 nm for UV-screening test and at 660 nm for transparency test. WVP value of carrageenan films with addition of ZnO is low compared to a control carrageenan film and the lowest WVP value was found for the film with addition of 1.5% of ZnO. These result indicate that the addition of ZnO had a positive effect on the water barrier properties of the carrageenan matrix. Increase in the concentration of nanofiller leads to an increase in the UV-screening properties. Among all the films, carrageenan film with 1.5% ZnO has the highest UV-screening. The result showed that adding 0.5% and 1.0% of ZnO was insignificantly affect transparency of the films, however the transparency decreased sligthly when 1.5% ZnO was added. In conclusion, incorporating no more than 1.0% of ZnO to the films can obtain films with high UV-screening, transparency and water barrier properties and suitable for food packaging application.

  17. Synthesis and Characterization of Nanostructured ZnO Thick Film Gas Sensors Prepared by Screen Printing Method

    Directory of Open Access Journals (Sweden)

    R. Y. BORSE

    2010-12-01

    Full Text Available Nanosized ZnO was prepared by self propagating solution combustion synthesis method. The synthesized ZnO thick films were deposited on alumina substrate by using standard screen printing technique and fired at 700 0C. The films were characterized by X-ray diffractometer (XRD, Scanning Electron Microscopy (SEM and energy dispersive analysis of X-ray (EDAX. The electrical behaviors of ZnO thick films were investigated. From XRD spectra it is revealed that ZnO films are polycrystalline in nature. The average grain size of 87.44 nm has been estimated for the film fired at 700 0C using Scherrer’s formula. EDAX clearly shows the peaks corresponding to Zn and O element which confirms the successful growth of ZnO films. Gas sensing study for these samples shows high sensitivity and selectivity towards NO2 at all operating temperatures. The resistivity, TCR and activation energy of the ZnO films have been evaluated and discussed.

  18. High Tc screen-printed YBa2Cu3O(7-x) films - Effect of the substrate material

    Science.gov (United States)

    Bansal, Narottam P.; Simons, Rainee N.; Farrell, D. E.

    1988-08-01

    Thick films of YBa2Cu3O(7-x) have been deposited on highly polished alumina, magnesia spinel, nickel aluminum titanate (Ni-Al-Ti), and barium tetratitanate (Ba-Ti) substrates by the screen printing technique. Properties of the films were found to be highly sensitive to the choice of the substrate material. The film on Ba-Ti turned green after firing, due to a reaction with the substrate and were insulating. A film on Ni-Al-Ti had a Tc (onset) of about 95 K and lost 90 percent of its resistance by about 75 K. However, even at 4 K it was not fully superconducting, possibly due to a reaction between the film and the substrate and interdiffusion of the reaction products. The film on alumina had Tc (onset) of about 96 K, Tc (zero) of about 66 K, and Delta Tc of about 10 K. The best film was obtained on spinel and had Tc (onset) of about 94 K, zero resistance at 81 K, and a transition width of about 7 K.

  19. Comparison of the image quality of digital radiography system and film screen system - Radiologist' rating of the visibility of normal anatomic - Structures in chest PA, Skull radiograph and K. U. B

    International Nuclear Information System (INIS)

    Song, Kounn Sik; Kim, Young Goo; Lee, Jong Beum; Kim, Kun Sang

    1987-01-01

    Digital image acquisition and display is widely used in computed tomography, ultrasonography, digital subtraction angiography, nuclear medicine and magnetic resonance image. But most of the radiological examinations performed in radiology department are made by using conventional system. The development of the digital radiography system is essential if totally digitized radiology department is desired. The advantages of digitizing the radiographic information are usually discussed in terms of PACS (picture archiving and communication system), furthermore there are many other advantages such as contrast modification, spatial filtering subtraction and superimposition of the images through the image processing by computer. Currently several approaches are under development or in clinical use, the most promising approach is the use of imaging plate composed of photostimulate phosphors such as barium fluorohalide crystal read with a He-Ne laser to produce digital radiographic images. Another promising approach is scan projection radiography. The authors performed the clinical study of comparing the image qualities of digital radiography system using scanning laser luminescence (FCR) and conventional film-screen system in chest PA, skull radiography and K. U. B. in terms of the visibility of the normal anatomic structure rating those (qualities) on a scale of 0 to 3 and obtained the following results. Normal contrast digital images are comparable to conventional film-screen images, but the images of high frequency enhancement is far superior to conventional film-screen especially in peripherally located structures such as skin, subcutaneous fat, musculoskeletal systems, nasal bone, inner and outer table of the skull including the diploic space, paranasal sinuses, nasopharynx and larynx, trachea and main bronchi, mediastinal structures, retrocardiac and subphrenic vascular markings. Another promising aspects of digital radiography system is its wide exposure latitude and

  20. Comparison of RT-PCR-Dot blot hybridization based on radioisotope 32P with conventional RT-PCR and commercial ELISA Assays for blood screening of HIV-1

    International Nuclear Information System (INIS)

    Maria Lina R; Andi Yasmon

    2011-01-01

    There are many commercial ELISA and rapid test kits that have been used for blood screening; however, the kits can give false positive and negative results. Therefore, RT-PCR (Reverse Transcription Polymerase Chain Reaction) - Dot Blot Hybridization based on radioisotope 32 P (RDBR) method was developed in this research, to compare the method with the conventional RT-PCR and commercial ELISA Enzyme-Linked lmmunosorbent Assay) kit. This method is efficient for screening of large blood specimens and surveillance study. Eighty seven samples were used and serum of the samples were tested by ELISA to detect HIV-1. The HIV-l RNA genome was extracted from plasma samples and tested using the RT-PCR and RDBR methods. Of 87 samples that were tested, the rates of positive testing of the RT-PCR, the RDBR, and the ELISA were 71.26%, 74.71%, and 80.46%, respectively. The RDBR (a combination of RTPCR and dot blot hybridization) was more sensitive than conventional RT-PCR by showing 3.45% in increase number of positive specimens. The results showed that of 9 samples (10.34%) were negative RDBR and positive ELISA, while 4 samples (4.60%) were negative ELISA and positive RDBR. The two methods showed slightly difference in the results but further validation is still needed. However, RDBR has high potential as an alternative method for screening of blood in large quantities when compared to method of conventional RT-PCR and ELISA. (author)

  1. Technique charts for Kodak EC-L film screen system for portal localization in a 6MV X-ray beam.

    Science.gov (United States)

    Sandilos, P; Antypas, C; Paraskevopoulou, C; Kouvaris, J; Vlachos, L

    2006-01-01

    Port films are used in radiotherapy for visual evaluation of the radiation fields and subsequent quantitative analysis. Common port films suffer from poor image quality compared to the simulator-diagnostic films and is desirable to determine the appropriate exposure required for the best image contrast. The aim of this work is to generate technique charts for the Kodak EC-L film screen system for use in a 6MV x-ray beam. Three homogeneous water phantoms were used to simulate head-neck, thorax and abdomen dimensions of adult human, correspondingly. The film screen system was calibrated in a 6MV x-ray beam and under various irradiation conditions. The film screen system behavior was studied as a function of phantom thickness, field size and air gap between the phantom and the film screen system. In each case the optimum film exposure which produces the maximum image contrast was determined. The generated technique charts for the EC-L film screen system and for a 6 MV x-ray beam are used in our radiotherapy department for daily quality assurance of the radiotherapy procedure.

  2. Microstructure and thermoelectric properties of screen-printed thick-films of misfit-layered cobalt oxides with Ag addition

    DEFF Research Database (Denmark)

    Van Nong, Ngo; Samson, Alfred Junio; Pryds, Nini

    2012-01-01

    Thermoelectric properties of thick (~60 μm) films prepared by a screen-printing technique using p-type misfit-layered cobalt oxide Ca3Co4O9+δ with Ag addition have been studied. The screen-printed films were sintered in air at various temperatures ranging from 973 K to 1223 K. After each sintering...... process, crystal and microstructure analyses were carried out to determine the optimal sintering condition. The results show that the thermoelectric properties of pure Ca3Co4O9+δ thick film are comparable to those of cold isostatic pressing (CIP) samples. We found that the maximum power factor...... was improved by about 67% (to 0.3 mW/m K2) for film with proper silver (Ag) metallic inclusions as compared with 0.18 mW/m K2 for pure Ca3Co4O9+δ film under the same sintering condition of 1223 K for 2 h in air....

  3. Interval breast cancer characteristics before, during and after the transition from screen-film to full-field digital screening mammography.

    Science.gov (United States)

    van Bommel, Rob M G; Weber, Roy; Voogd, Adri C; Nederend, Joost; Louwman, Marieke W J; Venderink, Dick; Strobbe, Luc J A; Rutten, Matthieu J C; Plaisier, Menno L; Lohle, Paul N; Hooijen, Marianne J H; Tjan-Heijnen, Vivianne C G; Duijm, Lucien E M

    2017-05-05

    To determine the proportion of "true" interval cancers and tumor characteristics of interval breast cancers prior to, during and after the transition from screen-film mammography screening (SFM) to full-field digital mammography screening (FFDM). We included all women with interval cancers detected between January 2006 and January 2014. Breast imaging reports, biopsy results and breast surgery reports of all women recalled at screening mammography and of all women with interval breast cancers were collected. Two experienced screening radiologists reviewed the diagnostic mammograms, on which the interval cancers were diagnosed, as well as the prior screening mammograms and determined whether or not the interval cancer had been missed on the most recent screening mammogram. If not missed, the cancer was considered an occult ("true") interval cancer. A total of 442 interval cancers had been diagnosed, of which 144 at SFM with a prior SFM (SFM-SFM), 159 at FFDM with a prior SFM (FFDM-SFM) and 139 at FFDM with a prior FFDM (FFDM-FFDM). The transition from SFM to FFDM screening resulted in the diagnosis of more occult ("true") interval cancers at FFDM-SFM than at SFM-SFM (65.4% (104/159) versus 49.3% (71/144), P screened digitally for the second time (57.6% (80/139) at FFDM-FFDM versus 49.3% (71/144) at SFM-SFM). Tumor characteristics were comparable for the three interval cancer cohorts, except of a lower porportion (75.7 and 78.0% versus 67.2% af FFDM-FFDM, P cancers at FFDM with prior FFDM. An increase in the proportion of occult interval cancers is observed during the transition from SFM to FFDM screening mammography. However, this increase seems temporary and is no longer detectable after the second round of digital screening. Tumor characteristics and type of surgery are comparable for interval cancers detected prior to, during and after the transition from SFM to FFDM screening mammography, except of a lower proportion of invasive ductal cancers after the

  4. Development of conductive coated polyester film as RPC electrodes using screen printing

    Science.gov (United States)

    Kalmani, S. D.; Mondal, N. K.; Satyanarayana, B.; Verma, P.; Datar, V. M.

    2009-05-01

    Each of the three 16 kton ICAL detector modules at the India-based Neutrino Observatory (INO) will use RPCs as the active element, sandwiched between 6 cm thick soft iron plates, for measurements on atmospheric neutrinos. The electrodes of the RPC are float glass sheets having a volume resistivity of about 10 12-10 13 Ω cm (at room temperature) covered with carbon/graphite or a conductive paint with a surface resistivity of ˜800 kΩ/square to 1 MΩ/square to apply high voltage on the glass surface, so that this surface does not shield the discharge signal from the external pickup plates and is small compared to the resistivity of the glass to provide a uniform potential across the entire surface. We initially coated the surface with locally available graphite powder, mixed with lacquer and thinner, and were able to get a few hundred kΩ/square resistivity. However, we observed a drastic reduction in surface resistivity with time and it came unstuck from the glass. Subsequently a conductive paint developed by Kansai-Nerolac was used. This paint uses modified acrylic resin as binder, conductive black pigment and solvents, which include aromatic hydrocarbons and alcohols. At room temperature, the surface dries in 10 minutes, while complete drying takes ˜18 hours. The spraying is done at a pressure of 4 kg/cm 2 with the glass plate kept at a distance of 8-10 in. Using this paint, we are able to achieve the required resistance of ˜ few hundred kΩ/square. We still need to study the long term stability and best curing method. We need to automate the procedure to get a uniform coat and to coat a large number of glasses for the final detector. While robotic systems are available abroad costing about 5 000 000 rupees, we are exploring other alternatives. In particular, we are in the process of developing a polyester film, with a conductive coating on one side, which can be glued on to the glass. The coating was done using on a local commercial screen printing machine

  5. Development of conductive coated polyester film as RPC electrodes using screen printing

    International Nuclear Information System (INIS)

    Kalmani, S.D.; Mondal, N.K.; Satyanarayana, B.; Verma, P.; Datar, V.M.

    2009-01-01

    Each of the three 16 kton ICAL detector modules at the India-based Neutrino Observatory (INO) will use RPCs as the active element, sandwiched between 6 cm thick soft iron plates, for measurements on atmospheric neutrinos. The electrodes of the RPC are float glass sheets having a volume resistivity of about 10 12 -10 13 Ω cm (at room temperature) covered with carbon/graphite or a conductive paint with a surface resistivity of ∼800 kΩ/square to 1 MΩ/square to apply high voltage on the glass surface, so that this surface does not shield the discharge signal from the external pickup plates and is small compared to the resistivity of the glass to provide a uniform potential across the entire surface. We initially coated the surface with locally available graphite powder, mixed with lacquer and thinner, and were able to get a few hundred kΩ/square resistivity. However, we observed a drastic reduction in surface resistivity with time and it came unstuck from the glass. Subsequently a conductive paint developed by Kansai-Nerolac was used. This paint uses modified acrylic resin as binder, conductive black pigment and solvents, which include aromatic hydrocarbons and alcohols. At room temperature, the surface dries in 10 minutes, while complete drying takes ∼18 hours. The spraying is done at a pressure of 4 kg/cm 2 with the glass plate kept at a distance of 8-10 in. Using this paint, we are able to achieve the required resistance of ∼ few hundred kΩ/square. We still need to study the long term stability and best curing method. We need to automate the procedure to get a uniform coat and to coat a large number of glasses for the final detector. While robotic systems are available abroad costing about 5 000 000 rupees, we are exploring other alternatives. In particular, we are in the process of developing a polyester film, with a conductive coating on one side, which can be glued on to the glass. The coating was done using on a local commercial screen printing

  6. Synthesis and Screening of Phase Change Chalcogenide Thin Film Materials for Data Storage.

    Science.gov (United States)

    Guerin, Samuel; Hayden, Brian; Hewak, Daniel W; Vian, Chris

    2017-07-10

    A combinatorial synthetic methodology based on evaporation sources under an ultrahigh vacuum has been used to directly synthesize compositional gradient thin film libraries of the amorphous phases of GeSbTe alloys at room temperature over a wide compositional range. An optical screen is described that allows rapid parallel mapping of the amorphous-to-crystalline phase transition temperature and optical contrast associated with the phase change on such libraries. The results are shown to be consistent with the literature for compositions where published data are available along the Sb 2 Te 3 -GeTe tie line. The results reveal a minimum in the crystallization temperature along the Sb 2 Te 3 -Ge 2 Te 3 tie line, and the method is able to resolve subsequent cubic-to-hexagonal phase transitions in the GST crystalline phase. HT-XRD has been used to map the phases at sequentially higher temperatures, and the results are reconciled with the literature and trends in crystallization temperatures. The results clearly delineate compositions that crystallize to pure GST phases and those that cocrystallize Te. High-throughput measurement of the resistivity of the amorphous and crystalline phases has allowed the compositional and structural correlation of the resistivity contrast associated with the amorphous-to-crystalline transition, which range from 5-to-8 orders of magnitude for the compositions investigated. The results are discussed in terms of the compromises in the selection of these materials for phase change memory applications and the potential for further exploration through more detailed secondary screening of doped GST or similar classes of phase change materials designed for the demands of future memory devices.

  7. Comparison of low contrast detectability of computed tomography and screen/film mammography systems

    International Nuclear Information System (INIS)

    Noriah Jamal; Kwan Hoong Ng; McLean, D.

    2006-01-01

    The objective of this study was to compare low contrast detectability of computed radiography (CR) and screen/film (SF) mammography systems. The Nijimegen contrast detail test object (CDMAM type 3.4) was imaged at 28 kV, in automatic exposure control mode separately. Six medical imaging physicists read each CDMAM phantom image. Contrast detail curves were plotted to compare low contrast detectability of CR (soft copy and hard copy) and SF mammography systems. Effect of varying exposure parameters, namely kV, object position inside the breast phantom, and entrance surface exposure (ESE) on the contrast detail curve were also investigated using soft copy CR. The significant of the difference of contrast between CR and SF, and for each exposure parameter was tested using non-parametric Kruskal-Wallis test. We found that the low contrast detectability of CR (soft copy and hard copy) system is not significantly different to that of SF system (p>0.05, Kruskal-Wallis test). For CR soft copy, no significant relationship (p>0.05, Kruskal-Wallis test) was seen for variation of kV, object position inside the breast phantom and ESE. This indicates that CR is comparable with SF for useful detection and visualization of low contrast objects such as small low contrast areas corresponding to breast pathology

  8. Comparison of low-contrast detectability of computed radiography and screen/ film mammography systems

    International Nuclear Information System (INIS)

    Noriah Jamal; Kwan-Hoong Ng; McLean, D.; McLean, D.

    2008-01-01

    The objective of this study is to compare low-contrast detectability of computed radiography (CR) and screen/ film (SF) mammography systems. The Nijimegen contrast detail test object (CDMAM type 3.4) was imaged at 28 kV, in automatic exposure control mode separately. Six medical imaging physicists read each CDMAM phantom image. Contrast detail curves were plotted to compare low-contrast detectability of CR (soft copy and hard copy) and SF mammography systems. Effect of varying exposure parameters, namely kV, object position inside the breast phantom, and entrance surface exposure (ESE) on the contrast detail curve were also investigated using soft copy CR. The significance of the difference in contrast between CR and SF, and for each exposure parameter, was tested using non-parametric Kruskal-Wallis test. The low-contrast detectability of the CR (soft copy and hard copy) system was found to be not significantly different to that of the SF system (p> 0.05, Kruskal-Wallis test).For CR soft copy, no significant relationship (p>0.05, Kruskal-Wallis test) was seen for variation of kV, object position inside the breast phantom and ESE. This indicates that CR is comparable with SF for useful detection and visualization of low-contrast objects such as small low-contrast areas corresponding to breast pathology. (Author)

  9. LPG and NH3 Sensing Properties of SnO2 Thick Film Resistors Prepared by Screen Printing Technique

    Directory of Open Access Journals (Sweden)

    A. S. GARDE

    2010-11-01

    Full Text Available The gas sensing behavior of SnO2 thick film resistors deposited on alumina substrates has been investigated for LPG and NH3 gas. The standard screen printing technology was used to prepare the thick films. The films were fired at optimized temperature of 780 0C for 30 minutes. The material characterization was performed by XRD, SEM, FTIR, UV and EDAX for elemental analysis. IR spectroscopy analysis at 2949.26 cm-1 showed the peak assigned to the –Sn-H vibration due to the effect of hybridization i.e. sp3 and the sharp peak at 3734.31 cm-1 assigned to –Sn-OH stretching vibration due to hydrogen bonding. The variation of D.C electrical resistance of SnO2 film samples was measured in air as well as in LPG and NH3 gas atmosphere as a function of temperature. The SnO2 film samples show negative temperature coefficient of résistance. The SnO2 film samples showed the highest sensitivity to 600 ppm of LPG at 230 0C and NH3 at 370 0C. The effect of microstructure on sensitivity, response time and recovery time of the sensor in the presence of LPG and NH3 gases were studied and discussed.

  10. A study of a reduction of patients' radiation exposure by using the new ortho screen film system

    International Nuclear Information System (INIS)

    Yagi, Hirofumi; Kuroda, Tokue.

    1994-01-01

    The developing temperatures dependency of the physical imaging properties of KONICA HI-ORTHO EXCELLENT SYSTEM (EX system) and KONICA MEDICAL SUPER RAPID SYSTEM (SR series) was evaluated by measuring characteristic curves, resolution properties and noise RMS. Furthermore, the possibility of a reduction of patients' radiation exposure without a decrease in imaging qualities was evaluated because the speed of screen/film systems increase as the developing temperature going up and the granularity of the EX system is greatly improved comparing with SR series. The physical imaging properties of screen/film systems were affected by the developing temperature. But the level of the effects on EX system was smaller than SR series. It was confirmed that the granularity of the EX system was improved greatly compared to SR series. Therefore, there is the possible reduction of patients' radiation exposure by increasing the developing temperature compared to the actual situation. (author)

  11. Field effect of screened charges: electrical detection of peptides and proteins by a thin-film resistor.

    Science.gov (United States)

    Lud, Simon Q; Nikolaides, Michael G; Haase, Ilka; Fischer, Markus; Bausch, Andreas R

    2006-02-13

    For many biotechnological applications the label-free detection of biomolecular interactions is becoming of outstanding importance. In this Article we report the direct electrical detection of small peptides and proteins by their intrinsic charges using a biofunctionalized thin-film resistor. The label-free selective and quantitative detection of small peptides and proteins is achieved using hydrophobized silicon-on-insulator (SOI) substrates functionalized with lipid membranes that incorporate metal-chelating lipids. The response of the nanometer-thin conducting silicon film to electrolyte screening effects is taken into account to determine quantitatively the charges of peptides. It is even possible to detect peptides with a single charge and to distinguish single charge variations of the analytes even in physiological electrolyte solutions. As the device is based on standard semiconductor technologies, parallelization and miniaturization of the SOI-based biosensor is achievable by standard CMOS technologies and thus a promising basis for high-throughput screening or biotechnological applications.

  12. A method of simultaneous no-screen X-ray film taking with direct twofold magnification of hands and feet

    International Nuclear Information System (INIS)

    Zajgner, J.; Szymanska-Prach, H.

    1978-01-01

    The authors propose an original method of X-ray examination of hands and feet which makes possible simultaneous radiography without screen and direct twofold magnified film taking. The method is not connected with the necessity of exposing the patient to an additional dose of X-rays. It has been tried in 20 patients with suspected rheumatoid arthritis. It requires an X-ray tube with 0.3 x 0.3 mm microfocus. (author)

  13. Determination of the Modulation Transfer Function of Screen-Film Combinations in X-ray photography by the grating method

    International Nuclear Information System (INIS)

    Hoeschen, D.

    1987-01-01

    An intercomparison experiment concerning the determination of the Modulation Transfer Function (MTF) of Screen-Film Combinations in x-ray photography by the grating method was made. Six laboratories located in four countries participated. Each laboratory has used its own, individually developed measurement procedure. The results have shown a surprisingly good agreement, the standard deviation (1 σ value) of MTF values reported by the different laboratories was about ± 0.02

  14. A Highly Thermostable In2O3/ITO Thin Film Thermocouple Prepared via Screen Printing for High Temperature Measurements

    Directory of Open Access Journals (Sweden)

    Yantao Liu

    2018-03-01

    Full Text Available An In2O3/ITO thin film thermocouple was prepared via screen printing. Glass additives were added to improve the sintering process and to increase the density of the In2O3/ITO films. The surface and cross-sectional images indicate that both the grain size and densification of the ITO and In2O3 films increased with the increase in annealing time. The thermoelectric voltage of the In2O3/ITO thermocouple was 53.5 mV at 1270 °C at the hot junction. The average Seebeck coefficient of the thermocouple was calculated as 44.5 μV/°C. The drift rate of the In2O3/ITO thermocouple was 5.44 °C/h at a measuring time of 10 h at 1270 °C.

  15. A high-performance, flexible and robust metal nanotrough-embedded transparent conducting film for wearable touch screen panels

    Science.gov (United States)

    Im, Hyeon-Gyun; An, Byeong Wan; Jin, Jungho; Jang, Junho; Park, Young-Geun; Park, Jang-Ung; Bae, Byeong-Soo

    2016-02-01

    We report a high-performance, flexible and robust metal nanotrough-embedded transparent conducting hybrid film (metal nanotrough-GFRHybrimer). Using an electro-spun polymer nanofiber web as a template and vacuum-deposited gold as a conductor, a junction resistance-free continuous metal nanotrough network is formed. Subsequently, the metal nanotrough is embedded on the surface of a glass-fabric reinforced composite substrate (GFRHybrimer). The monolithic composite structure of our transparent conducting film allows simultaneously high thermal stability (24 h at 250 °C in air), a smooth surface topography (Rrms touch screen panel (TSP) is fabricated using the transparent conducting films. The flexible TSP device stably operates on the back of a human hand and on a wristband.We report a high-performance, flexible and robust metal nanotrough-embedded transparent conducting hybrid film (metal nanotrough-GFRHybrimer). Using an electro-spun polymer nanofiber web as a template and vacuum-deposited gold as a conductor, a junction resistance-free continuous metal nanotrough network is formed. Subsequently, the metal nanotrough is embedded on the surface of a glass-fabric reinforced composite substrate (GFRHybrimer). The monolithic composite structure of our transparent conducting film allows simultaneously high thermal stability (24 h at 250 °C in air), a smooth surface topography (Rrms touch screen panel (TSP) is fabricated using the transparent conducting films. The flexible TSP device stably operates on the back of a human hand and on a wristband. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr07657a

  16. Differences in radiological patterns, tumour characteristics and diagnostic precision between digital mammography and screen-film mammography in four breast cancer screening programmes in Spain

    International Nuclear Information System (INIS)

    Domingo, Laia; Sala, Maria; Romero, Anabel; Belvis, Francesc; Macia, Francesc; Castells, Xavier; Sanchez, Mar; Ferrer, Joana; Salas, Dolores; Ibanez, Josefa; Vega, Alfonso; Ferrer, Francesc; Laso, M.S.

    2011-01-01

    To compare tumour characteristics between cancers detected with screen-film mammography (SFM) and digital mammography (DM) and to evaluate changes in positive predictive values (PPVs) for further assessments, for invasive procedures and for distinct radiological patterns in recalled women. 242,838 screening mammograms (171,191 SFM and 71,647 DM) from 103,613 women aged 45-69 years, performed in four population-based breast cancer screening programmes in Spain, were included. The tumour characteristics and PPVs of each group were compared. Radiological patterns (masses, calcifications, distortions and asymmetries) among recalled women were described and PPVs were evaluated. The percentages of ductal carcinoma in situ (DCIS) were higher in DM than in SFM both in the first [18.5% vs. 15.8%(p = 0.580)] and in successive screenings [23.2% vs. 15.7%(p = 0.115)]. PPVs for masses, asymmetries and calcifications were higher in DM, being statistically significant in masses (5.3% vs. 3.9%; proportion ratio: 1.37 95%CI: 1.08-1.72). Among cancers detected by calcifications, the percentage of DCIS was higher in DM (60.3% vs. 46.4%, p = 0.060). PPVs were higher when DM was used, both for further assessments and for invasive procedures, with similar cancer detection rates and no statistically significant differences in tumour characteristics. The greatest improvements in PPVs were found for masses. (orig.)

  17. Differences in radiological patterns, tumour characteristics and diagnostic precision between digital mammography and screen-film mammography in four breast cancer screening programmes in Spain

    Energy Technology Data Exchange (ETDEWEB)

    Domingo, Laia; Sala, Maria [IMIM-Hospital del Mar, Department of Epidemiology and Evaluation, Barcelona (Spain); CIBER de Epidemiologia y Salud Publica (CIBERESP), Barcelona (Spain); Universitat Autonoma de Barcelona (UAB), EHEA Doctoral Program in Public Health. Department of Pediatrics, Obstetrics and Gynecology, Preventive Medicine and Public Health, Barcelona (Spain); Romero, Anabel; Belvis, Francesc; Macia, Francesc; Castells, Xavier [IMIM-Hospital del Mar, Department of Epidemiology and Evaluation, Barcelona (Spain); CIBER de Epidemiologia y Salud Publica (CIBERESP), Barcelona (Spain); Sanchez, Mar [Government of Cantabria, General Directorate of Public Health, Department of Health, Santander (Spain); Ferrer, Joana [Radiology Unit. Hospital Santa Caterina, Girona (Spain); Salas, Dolores; Ibanez, Josefa [General Directorate Public Health and Centre for Public Health Research (CSISP), Valencia (Spain); Vega, Alfonso [Hospital Universitario Marques de Valdecilla, Radiology Unit, Santander (Spain); Ferrer, Francesc [Hospital del Mar, Radiology and Nuclear Medicine Service, Barcelona (Spain); Laso, M.S. [Breast Cancer Screening Unit Burjassot, Valencia (Spain)

    2011-09-15

    To compare tumour characteristics between cancers detected with screen-film mammography (SFM) and digital mammography (DM) and to evaluate changes in positive predictive values (PPVs) for further assessments, for invasive procedures and for distinct radiological patterns in recalled women. 242,838 screening mammograms (171,191 SFM and 71,647 DM) from 103,613 women aged 45-69 years, performed in four population-based breast cancer screening programmes in Spain, were included. The tumour characteristics and PPVs of each group were compared. Radiological patterns (masses, calcifications, distortions and asymmetries) among recalled women were described and PPVs were evaluated. The percentages of ductal carcinoma in situ (DCIS) were higher in DM than in SFM both in the first [18.5% vs. 15.8%(p = 0.580)] and in successive screenings [23.2% vs. 15.7%(p = 0.115)]. PPVs for masses, asymmetries and calcifications were higher in DM, being statistically significant in masses (5.3% vs. 3.9%; proportion ratio: 1.37 95%CI: 1.08-1.72). Among cancers detected by calcifications, the percentage of DCIS was higher in DM (60.3% vs. 46.4%, p = 0.060). PPVs were higher when DM was used, both for further assessments and for invasive procedures, with similar cancer detection rates and no statistically significant differences in tumour characteristics. The greatest improvements in PPVs were found for masses. (orig.)

  18. Comparison between film-screen and computed radiography systems in Brazilian mammography

    International Nuclear Information System (INIS)

    Vieira, L.A.; Oliveira, J.R.; Carvalho, L.A.P.; César, A.C.Z.; Nogueira, M.S.

    2015-01-01

    Since 2004 the Public Health Office of the State of Minas Gerais in Brazil has established the Image Quality Control Program in Mammography. It evaluates the image quality based on an accredited phantom of the Brazilian College of Radiology (CBR). This phantom follows international standards such as masses, specks, fibers, contrast details and spatial resolution. The contrast index (CI) is accessed through optical density (OD) measurements. Although OD is defined under film-screen (FS) scope, among all accessible mammographic systems under the health office surveillance, almost 80% are computed radiography (CR) based. A necessity to adapt the protocol has emerged to consider OD as a conformity parameter. Objective: To verify the OD accessibility under CR´s printed out films and the feasibility to calculate contrast index, in comparison with FS´s. Results: A total of 56 images were evaluated with three different CBR phantoms. They were equally divided into FS and CR systems and a densitometer was used to read out their OD values. The correlation between their contrast-to-noise ratio (CNR) was found to be in the order of 0.77 (±0.14). The samples were not significantly different (inside 5% incertitude) for every phantom. The CNR correlation coefficient was 0.871. For OD, correlation coefficient was 0.989 and a log-fit function has shown good agreement with detector response. The OD-normalized standard deviation difference between CR and FS for every different phantom was 36.6%, 2.8% and 20.2%. A CI range for CR´s lying between 0.13 and 0.69 was found. Conclusions: Different phantoms were successfully tested in both CR and FS to evaluate the feasibility in use contrast index as a conformity parameter since their correlations are strictly related to calibration curve, as provided by phantom manufacturer. The relative CR-FS OD σ-difference provides a spreading indicator, where the first and last phantoms are considerably out of expectation. Such differences are

  19. Use of a modified GreenScreen tool to conduct a screening-level comparative hazard assessment of conventional silver and two forms of nanosilver

    OpenAIRE

    Sass, Jennifer; Heine, Lauren; Hwang, Nina

    2016-01-01

    Background Increased concern for potential health and environmental impacts of chemicals, including nanomaterials, in consumer products is driving demand for greater transparency regarding potential risks. Chemical hazard assessment is a powerful tool to inform product design, development and procurement and has been integrated into alternative assessment frameworks. The extent to which assessment methods originally designed for conventionally-sized materials can be used for nanomaterials, wh...

  20. Mammographic findings of women recalled for diagnostic work-up in digital versus screen-film mammography in a population-based screening program

    International Nuclear Information System (INIS)

    Lipasti, Seppo; Pamilo, Martti; Anttila, Ahti

    2010-01-01

    Background: Limited information is available concerning differences in the radiological findings of women recalled for diagnostic work-up in digital mammography (DM) versus screen-film mammography (SFM) screening. Purpose: To compare the radiological findings, their positive predictive values (PPVs) for cancer and other process indicators of DM screening performed by computed radiography (CR) technology and SFM screening in a population-based program. Material and Methods: The material consisted of women, 50-59 years of age, who were invited for screening: 30 153 women with DM in 2007-2008 and 32 939 women with SFM in 1999-2000. The attendance rate was 77.7% (23 440) in the DM arm and 83.8% (27 593) in the SFM arm. In the DM arm, 1.71% of those screened (401) and in the SFM arm 1.59% (438) were recalled for further work-up. The images resulting in the recall were classified as: 1) tumor-like mass, 2) parenchymal distortion/asymmetry, 3) calcifications, and 4) combination of mass and calcifications. The distributions of the various radiological findings and their PPVs for cancer were compared in both study groups. The recall rates, cancer detection rates, test specificities, and PPVs of the DM and SFM groups were also compared. Results: Women were recalled for diagnostic work-up most often due to tumor-like mass. It was more common in SFM (1.08% per woman screened) than in DM (0.93%). The second most common finding was parenchymal distortion and asymmetry, more often in DM (0.58%) than in SFM (0.37%). Calcifications were the third most common finding. DM exposed calcifications more often (0.49%) than SFM (0.26%). The PPVs for cancer of the recalls were higher in DM than in SFM in all subgroups of radiological findings. The test specificities were similar (DM 98.9%, SFM 98.8%). Significantly more cancers were detected by DM (cancer detection rate 0.623% per woman screened, n=146) than by SFM (cancer detection rate 0.406% per woman screened, n=112). The PPVs for

  1. Surface-screening mechanisms in ferroelectric thin films and their effect on polarization dynamics and domain structures

    Science.gov (United States)

    Kalinin, Sergei V.; Kim, Yunseok; Fong, Dillon D.; Morozovska, Anna N.

    2018-03-01

    For over 70 years, ferroelectric materials have been one of the central research topics for condensed matter physics and material science, an interest driven both by fundamental science and applications. However, ferroelectric surfaces, the key component of ferroelectric films and nanostructures, still present a significant theoretical and even conceptual challenge. Indeed, stability of ferroelectric phase per se necessitates screening of polarization charge. At surfaces, this can lead to coupling between ferroelectric and semiconducting properties of material, or with surface (electro) chemistry, going well beyond classical models applicable for ferroelectric interfaces. In this review, we summarize recent studies of surface-screening phenomena in ferroelectrics. We provide a brief overview of the historical understanding of the physics of ferroelectric surfaces, and existing theoretical models that both introduce screening mechanisms and explore the relationship between screening and relevant aspects of ferroelectric functionalities starting from phase stability itself. Given that the majority of ferroelectrics exist in multiple-domain states, we focus on local studies of screening phenomena using scanning probe microscopy techniques. We discuss recent studies of static and dynamic phenomena on ferroelectric surfaces, as well as phenomena observed under lateral transport, light, chemical, and pressure stimuli. We also note that the need for ionic screening renders polarization switching a coupled physical–electrochemical process and discuss the non-trivial phenomena such as chaotic behavior during domain switching that stem from this. ).

  2. Surface-screening mechanisms in ferroelectric thin films and their effect on polarization dynamics and domain structures

    Energy Technology Data Exchange (ETDEWEB)

    Kalinin, Sergei V.; Kim, Yunseok; Fong, Dillon D.; Morozovska, Anna N.

    2018-01-25

    For over 70 years, ferroelectric materials have been one of the central research topics for condensed matter physics and material science, an interest driven both by fundamental science and applications. However, ferroelectric surfaces, the key component of ferroelectric films and nanostructures, still present a significant theoretical and even conceptual challenge. Indeed, stability of ferroelectric phase per se necessitates screening of polarization charge. At surfaces, this can lead to coupling between ferroelectric and semiconducting properties of material, or with surface (electro) chemistry, going well beyond classical models applicable for ferroelectric interfaces. In this review, we summarize recent studies of surface-screening phenomena in ferroelectrics. We provide a brief overview of the historical understanding of the physics of ferroelectric surfaces, and existing theoretical models that both introduce screening mechanisms and explore the relationship between screening and relevant aspects of ferroelectric functionalities starting from phase stability itself. Given that the majority of ferroelectrics exist in multiple-domain states, we focus on local studies of screening phenomena using scanning probe microscopy techniques. We discuss recent studies of static and dynamic phenomena on ferroelectric surfaces, as well as phenomena observed under lateral transport, light, chemical, and pressure stimuli. We also note that the need for ionic screening renders polarization switching a coupled physical-electrochemical process and discuss the non-trivial phenomena such as chaotic behavior during domain switching that stem from this.

  3. Evaluation of XD/A Plus and ST8G films for cephalometric radiography with Grenex G8 and BH-III screens.

    Science.gov (United States)

    Wakoh, M; Farman, A G; Scarfe, W C; Shibuya, H; Nishikawa, K; Kuroyanagi, K

    1997-02-01

    Sensitometric properties, clinical image quality, and patient dose requirements are important considerations when selecting film for cephalometrics. Two recently released films, XD/A Plus and ST 8G green sensitive films, were studied. The films were each combined with Grenex G8 (Fuji Medical) green-fluorescing matched and BH-III (Kasei Optonix) blue-fluorescing mismatched intensifying screens. The density response and resolution for each screen-film combination were evaluated by use of the characteristic curve and modulation transfer function. The kilovoltage settings providing clinically acceptable images were assessed individually by 12 observers. Clinically acceptable images for each combination were also compared, and the skin entrance doses in the temporomandibular joint region were determined. The average contrast at the most effective density range was found to be slightly higher for the BH-III group than for the G8 group. The modulation transfer function for the BH-III group was inferior to that for the G8 screens. There were no significant differences in diagnostically acceptable image quality among the four combinations; nevertheless the BH-III screen group required two to three times more exposure than the G8 screen group. XD/A Plus and ST8G films provide acceptable image detail for cephalometrics. To minimize the patient dose they should be used with green-emitting screens.

  4. Differences of X-ray exposure between X-ray diagnostics with a conventional X-ray screen-system and with an image-intensifier-television-unit

    International Nuclear Information System (INIS)

    Loehr, H.; Vogel, H.; Reinhart, J.; Jantzen, R.

    1977-01-01

    During X-ray diagnostics of patients in the II. Medizinische Poliklinik the X-ray exposure was determined. It corresponded to the data described in literature. Two groups were compared: 518 patients examined with a conventional X-ray screen-system and 642 patients examined with an image-intensifier-television-system. The results demonstrated that with exception of thoracical X-ray examination the replacing of the old system by the television system brought a remarkable increase of the X-ray exposure. The doses depended of the patients constitution to a high degree. (orig.) [de

  5. Signal detectability of mammography depends on film-screen system and luminance of view box

    International Nuclear Information System (INIS)

    Maeda, Fumie; Ogura, Akio; Miyai, Akira

    2003-01-01

    High-density film and the high-luminance view-box system are being recommended for mammograms owing to the improved detection of masses. However, this system causes an increase in radiation. Therefore, the purpose of this study was to assess whether the detection of masses would improve using the normal-luminance view box and normal-density film with different types of contrast systems. Low-contrast detection using receiver operating characteristic (ROC) analysis and high-contrast detection using an American College of Radiology (ACR) phantom were evaluated for the following systems: high-density film and high-luminance view box, normal-density film and normal-luminance view box, and normal-density film with wide latitude and normal-luminance view box. The results showed no significant variation in the detectability of the system with high-density film and high-luminance view box and the normal-density film with wide latitude and normal-luminance view box. However, in terms of low-contrast visibility, the system using normal-density film and normal-luminance view box was significantly reduced in comparison with the others. Therefore, the system with normal-density film with wide latitude and the normal-luminance view box is recommended because of reduced radiation dose. (author)

  6. Spectral and spatial characteristics of x-ray film/screen combinations up to x-ray energy of 3 MeV

    International Nuclear Information System (INIS)

    Ginzburg, A.; Carmel, Y.; Segal, Y.; Notea, A.

    1986-01-01

    The present study is directed towards quantifying some of the parameters which define the quality of the image obtained on x-ray sensitive films and its usual accompanying intensifying screens. Both industrial (Agfa-Geveart D2,D4,D7) and medical (Kodak XAR-5) films with a variety of screens such as metallic (lead) and fluorescent (calcium tungstate, rare earth) were compared. A variety of sources were employed (radioactive, linear accelerators, flash) in order to cover the average x-ray energy spectrum from 100KeV to 3000KeV. This energy spectrum is of interest for non destructive testing, terminal ballistics and for medical purposes. The results indicate that the sensitivity of industrial x-ray films decreases with energy in the range of 100KeV to 1MeV, levels off and increases again with increasing energy. A 2.75MeV Na 24 radioactive source was used to achieve accurate calibration at the high end of the spectrum. Also, the noise level of x-ray industrial films versus film density was found to peak at a density of D=1.4. The line spread function (LSF) - or resolution - of both industrial and medical film/screen combinations were derived from the optical density of a step wedge response on the film. The noise level of medical films is twice as high compared to industrial films and their LSF is 4 to 8 times larger at x-ray energies of 3MeV. Using Pb screens in contact with common industrial x-ray films yields amplification of 2 (compared to a bare film)

  7. [Comparison of film-screen combinations in contrast-detail diagram and with interactive image analysis. 3: Trimodal histograms of gray scale distribution in bar groups of lead pattern images].

    Science.gov (United States)

    Hagemann, G; Eichbaum, G; Stamm, G

    1998-05-01

    The following four screen film combinations were compared: a) a combination of anticrossover film and UV-light emitting screens, b) a combination of blue-light emitting screens and film and c) two conventional green fluorescing screen film combinations. Radiographs of a specially designed plexiglass phantom (0.2 x 0.2 x 0.12 m3) with bar patterns of lead and plaster and of air, respectively were obtained using the following parameters: 12 pulse generator, 0.6 mm focus size, 4.7 mm aluminum prefilter, a grid with 40 lines/cm (12:1) and a focus-detector distance of 1.15 m. Image analysis was performed using an Ibas system and a Zeiss Kontron computer. Display conditions were the following: display distance 0.12 m, a vario film objective 35/70 (Zeiss), a video camera tube with a PbO photocathode, 625 lines (Siemens Heimann), an Ibas image matrix of 512 x 512 pixels with a spatial resolution of ca. 7 cycles/mm, the projected matrix area was 5000 micron 2. Maxima in the histograms of a grouped bar pattern were estimated as mean values from the bar and gap regions ("mean value method"). They were used to calculate signal contrast, standard deviations of the means and scatter fraction. Comparing the histograms with respect to spatial resolution and kV setting a clear advantage of the UVR system becomes obvious. The quantitative analysis yielded a maximum spatial resolution of approx. 3 cycles/mm for the UVR system at 60 kV which decreased to half of this value at 117 kV caused by the increasing influence of scattered radiation. A ranking of screen-film systems with respect to image quality and dose requirement is presented. For its evaluation an interactive image analysis using the mean value method was found to be superior to signal/noise ratio measurements and visual analysis in respect to diagnostic relevance and saving of time.

  8. Comparison of screen film combinations: results of a contrast detail study and interactive image quality analysis. Pt. III. Trimodal histograms of grey-value distributions found in the images of grouped lead bar pattern

    International Nuclear Information System (INIS)

    Hagemann, G.; Eichbaum, G.; Stamm, G.

    1998-01-01

    The following four screen film combinations were compared: (a) a combination of anticrossover film and UV-light emitting screens, (b) a combination of blue-light emitting screens and film and (c) two conventional green fluorescing screen film combinations. Radiographs of a specially designed plexiglass phantom (0.2 x 0.2 x 0.12 m 3 ) with bar patterns of lead and plaster and of air, respectively were obtained using the following parameters: 12 pulse generator, 0.6 mm focus size, 4.7 mm aluminum prefilter, a grid with 40 lines/cm (12:1) and a focus-detector distance of 1.15 m. Image analyses was performed using an Ibas system and a Zeiss Kontron computer. Display conditions were the following: display distance 0.12 m, a vario film objective 35/70 (Zeiss), a video camera tube with a PbO photocathode, 625 lines (Siemens Heimann), an Ibas image matrix of 512 x 512 pixels with a spatial resolution of ca. 7 cycles/mm, the projected matrix area was 5000 μm 2 . Maxima in the histograms of a grouped bar pattern were estimated as mean values from the bar and gap regions ('mean value method'). They were used to calculate signal contrast, standard deviations of the means and scatter fraction. Comparing the histograms with respect to spatial resolution and kV setting a clear advantage of the UVR system becomes obvious. The quantitative analysis yielded a maximum spatial resolution of approx. 3 cycles/mm for the UVR system at 60 kV which decreased to half of this value at 117 kV caused by the increasing influence of scattered radiation. A ranking of screen-film systems with respect to image quality and dose requirement is presented. For its evaluation an interactive image analysis using the mean value method was found to be superior to signal/noise ratio measurements and visual analysis in respect to diagnostic relevance and saving of time. (orig./MG) [de

  9. Comparison of modulation transfer function, noise power spectrum, and sensitometric measurements of x-ray screen-film systems made in two different laboratories

    International Nuclear Information System (INIS)

    Sandrik, J.M.; Jennings, R.J.; Wagner, R.F.

    1980-01-01

    A project to develop standardization in the measurement of fundamental characteristics of screen-film systems is described. This project is a comparison of measurements on the same film samples performed by both the Kurt Rossmann Laboratories for Radiologic Image Research at the University of Chicago and by the Radiologic Imaging Section in the Medical Physics Branch, Division of Electronic Products. For this comparison we are making three fundamental measurements that characterize the operation of the screen-film systems. One is sensitometry of the characteristic or H and D curve. The film darkening is studied as a function of x-ray exposure to the screen-film system. This provides information on the speed and contrast of the system and it is also used in the determination of the MTF. The second measurement is the spatial frequency response or the MTF. For this measurement the screen-film system is exposed through a slit about 10 microns wide. This provides information on the fidelity with which contrast in the object is transferred to the image and information on the resolution of the image receptor. The third measure is the noise power or Wiener spectrum. In this case the film is exposed to a uniform x-ray field and the image provides information on the noise content of the receptor as a function of spatial frequency so that the effect of noise on the signal can be assessed

  10. Ethanol vapour sensing properties of screen printed WO 3 thick films

    Indian Academy of Sciences (India)

    The ethanol vapour sensing properties of these thick films were investigated at different operating temperatures and ethanol vapour concentrations. The WO3 thick films exhibit excellent ethanol vapour sensing properties with a maximum sensitivity of ∼1424.6% at 400°C in air atmosphere with fast response and recovery ...

  11. Cathodoluminescent characteristics and light technical parameters of thin-film screens based on oxides and oxysulfides of rare-earth elements

    Science.gov (United States)

    Bondar, Vyacheslav D.; Grytsiv, Myroslav; Groodzinsky, Arkady; Vasyliv, Mykhailo

    1995-11-01

    Results on creation of thin-film single-crystal high-resolution screens with energy control of luminescence color are presented. In order to create phosphor films ion-plasma technology for deposition of yttrium and lanthanum oxides and oxysulfides activated by rare earth elements has been developed. The screen consists of phosphor film on phosphor substrate with different colors of luminescence (e.g. Y2O3-Eu film with red color on Y3Al5O12- Tb, Ce substrate with green color of luminescence). Electron irradiation causes luminescence with color that depends on energy of the electron beam. The physical reason for color change is that electron beam energy defines electron penetration depth. If the energy is weak, only the film is excited. More powerful beam penetrates into the substrate and thus changes the color of luminescence.

  12. Interplay of Cu and oxygen vacancy in optical transitions and screening of excitons in ZnO:Cu films

    International Nuclear Information System (INIS)

    Darma, Yudi; Rusydi, Andrivo; Seng Herng, Tun; Marlina, Resti; Fauziah, Resti; Ding, Jun

    2014-01-01

    We study room temperature optics and electronic structures of ZnO:Cu films as a function of Cu concentration using a combination of spectroscopic ellipsometry, photoluminescence, and ultraviolet-visible absorption spectroscopy. Mid-gap optical states, interband transitions, and excitons are observed and distinguishable. We argue that the mid-gap states are originated from interactions of Cu and oxygen vacancy (Vo). They are located below conduction band (Zn4s) and above valence band (O2p) promoting strong green emission and narrowing optical band gap. Excitonic states are screened and its intensities decrease upon Cu doping. Our results show the importance of Cu and Vo driving the electronic structures and optical transitions in ZnO:Cu films

  13. Comparison of simulated light sensitometer and x-ray sensitometer for screen-film system in medical radiology

    International Nuclear Information System (INIS)

    Tsuyama, Yasuko; Yamamoto, Yoshinori.

    1983-01-01

    Sensitometric techniques are used for determining the characteristic curve in medical imaging. In this study intensity-scale (inverse square law, simulated light) methods are used in the determination of radiographic screen-film system characteristic curve. Films which were exposed to simulated light and x-ray were processed in the same automatic processor simultaneously. These curves were overlapped at Net density of 1.0 to compare the curve shapes. The results show there is a good correlation between the density of x-ray sensitometry and that of simulated light sensitometry. The differences of density are within +- 0.12 (+- 10 % log exposure). This applies to both blue sensitive and green sensitive systems. (author)

  14. Interplay of Cu and oxygen vacancy in optical transitions and screening of excitons in ZnO:Cu films

    Science.gov (United States)

    Darma, Yudi; Seng Herng, Tun; Marlina, Resti; Fauziah, Resti; Ding, Jun; Rusydi, Andrivo

    2014-02-01

    We study room temperature optics and electronic structures of ZnO:Cu films as a function of Cu concentration using a combination of spectroscopic ellipsometry, photoluminescence, and ultraviolet-visible absorption spectroscopy. Mid-gap optical states, interband transitions, and excitons are observed and distinguishable. We argue that the mid-gap states are originated from interactions of Cu and oxygen vacancy (Vo). They are located below conduction band (Zn4s) and above valence band (O2p) promoting strong green emission and narrowing optical band gap. Excitonic states are screened and its intensities decrease upon Cu doping. Our results show the importance of Cu and Vo driving the electronic structures and optical transitions in ZnO:Cu films.

  15. Mental health on screen: A DSM-5 dissection of portrayals of autism spectrum disorders in film and TV.

    Science.gov (United States)

    Nordahl-Hansen, Anders; Tøndevold, Magnus; Fletcher-Watson, Sue

    2018-04-01

    Portrayals of characters with autism spectrum disorders (ASD) in films and TV series are subject to intense debate over whether such representations are accurate. Inaccurate portrayals are a concern as they may lead to increased stereotypes toward the condition. We investigate whether portrayals of characters with autism spectrum disorder in film and TV-series align with DSM-5 diagnostic criteria. Our data show that characters present a full range of characteristics described in the DSM-5. The meaning of this finding is discussed in relation to potential educational value of on screen portrayals and the notion of authenticity in representing the autistic experience. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Screen-film mammography versus full-field digital mammography in a population-based screening program: The Sogn and Fjordane study

    International Nuclear Information System (INIS)

    Juel, Inger-Marie; Johannessen, Gunnar; Skaane, Per; Roth Hoff, Solveig; Hofvind, Solveig

    2010-01-01

    Background: Studies comparing analog and digital mammography in breast cancer screening have shown conflicting results. Little is known about the use of digital photon-counting detectors. Purpose: To retrospectively compare performance indicators in screen-film (SFM) and full-field digital mammography (FFDM) using a photon-counting detector in a population-based screening program. Material and Methods: The Norwegian Social Science Data Services approved the study, which was part of the Norwegian Breast Cancer Screening Program. The program invites women aged 50-69 years to two-view mammography biannually. The study period was January 2005 to June 2006 for SFM and August 2006 to December 2007 for FFDM. Independent double reading was performed using a five-point rating scale for probability of cancer. Recalls due to abnormal mammography were retrospectively reviewed by an expert panel. Performance indicators for the two techniques were compared. Attendance rate was 83.6% (7442/8901) for SFM and 82.0% (6932/8451) for FFDM. Results: The recall rate due to abnormal mammography, cancer detection rate and positive predictive value did not differ significantly between SFM and FFDM: recall 2.3% (174/7442) versus 2.4% (168/6932), cancer detection 0.39% (29/7442) versus 0.48% (33/6932), positive predictive value 16.7% (29/174) versus 19.6% (33/168), respectively (P>0.05 for all). The recall rate due to technically inadequate mammograms was 0.3% (19/7442) for SFM and 0.01% (1/6932) for FFDM. In the retrospective review, a significantly higher proportion of calcifications and asymmetric density were categorized as normal or definitively benign in FFDM compared with SFM. The average glandular dose was 2.17 mGy for SFM and 1.25 mGy for FFDM. Conclusion: Performance indicators show that FFDM using photon-counting detector is suitable for breast cancer screening. The lower radiation dose and lower recalls due to technically inadequate mammograms are of importance in mammography

  17. Screen printed PZT/PZT thick film bimorph MEMS cantilever device for vibration energy harvesting

    DEFF Research Database (Denmark)

    Xu, Ruichao; Lei, Anders; Dahl-Petersen, Christian

    2012-01-01

    We present a microelectromechanical system (MEMS) based PZT/PZT thick film bimorph vibration energy harvester with an integrated silicon proof mass. Most piezoelectric energy harvesting devices use a cantilever beam of a non piezoelectric material as support beneath or in-between the piezoelectric...... elements. We show experimental results from two types PZT/PZT harvesting devices, one where the Pb(ZrxTi1−x)O3 (PZT) thick films are high pressure treated during the fabrication and the other where the treatment is omitted. We find that with the high pressure treatment prior to PZT sintering, the films...

  18. Loss and benefit of DR system in mass screening for upper GI-tracts. Comparison with an II-TV based DR system and 100-mm roll-film system

    International Nuclear Information System (INIS)

    Ogura, Toshihiro; Fujita, Hiroshi.

    1995-01-01

    A 2048 x 2048 matrix II-TV based digital radiography (DR) system, a fully digital imaging system with diagnosis on the CRT monitor, had been introduced to Cancer Institute Hospital for the GI-tracts examinations since January 1990. Furthermore, we had applied it to the mass screening of upper GI-tract since November 1992. In the present study, a retrospective study on clinical evaluation and features of the DR system for the mass screening were investigated and compared with the screening data taken by conventional 100-mm roll-film technique in the previous year. The loss ratios and appearance of the mucosal patterns in upper gastric images were studied as well. Also determined was the reading time of those images in the mass screening situation. It was found that the loss ratio on the subject image information in 100-mm roll-film images was smaller than that in DR images. However, the DR images processed by windowing technique provided the perfect information without partially over or under density area. It was shown that the clinical image quality greatly depended on the radiographic technique by radiologists or technologists rather than on the imaging modality itself employed; even in II/TV-DR system, the radiographic technique is important. Because of some issues, including the size of CRT monitor, eyestrain for CRT monitor, and windowing operation regard to reading system, the reading time of CRT images was 1.44-2.05 times longer than that of 100-mm roll-film images. (author)

  19. Ethanol vapour sensing properties of screen printed WO3 thick films

    Indian Academy of Sciences (India)

    TECS

    trations. The WO3 thick films exhibit excellent ethanol vapour sensing properties with a maximum sensitivity ... methanol, acetone, isopropanol and acetic acid, have been reported .... maximum sensitivity was obtained at an operating tem-.

  20. Images of Youth on Screen: Manipulative Translation Strategies in the Dubbing of American Teen Films

    OpenAIRE

    Zanotti, Serenella

    2016-01-01

    Teen films have often been a locus of censorial intervention due to the sensitive issues that youth-centred stories most typically address, especially when it comes to the representation of family life, juvenile delinquency, violence, youth sexuality and language. This paper offers an analysis of the dubbed versions of three mainstream youth films from the 1950s, 1960s and 1970s, namely Rebel Without a Cause (Nicholas Ray, 1955), Splendor in the Grass (Elia Kazan, 1961) and The Summer of 42 (...

  1. Comparative alternative materials assessment to screen toxicity hazards in the life cycle of CIGS thin film photovoltaics

    International Nuclear Information System (INIS)

    Eisenberg, Daniel A.; Yu, Mengjing; Lam, Carl W.; Ogunseitan, Oladele A.; Schoenung, Julie M.

    2013-01-01

    Highlights: • Comparative alternatives assessment of thin film manufacturing technologies. • Development of chemical alternatives assessment in a life cycle context. • Screening of manufacturing and solar cell hazardous substances simultaneously. -- Abstract: Copper–indium–gallium–selenium–sulfide (CIGS) thin film photovoltaics are increasingly penetrating the market supply for consumer solar panels. Although CIGS is attractive for producing less greenhouse gas emissions than fossil-fuel based energy sources, CIGS manufacturing processes and solar cell devices use hazardous materials that should be carefully considered in evaluating and comparing net environmental benefits of energy products. Through this research, we present a case study on the toxicity hazards associated with alternative materials selection for CIGS manufacturing. We applied two numeric models, The Green Screen for Safer Chemicals™ and the Toxic Potential Indicator. To improve the sensitivity of the model outputs, we developed a novel, life cycle thinking based hazard assessment method that facilitates the projection of hazards throughout material life cycles. Our results show that the least hazardous CIGS solar cell device and manufacturing protocol consist of a titanium substrate, molybdenum metal back electrode, CuInS 2 p-type absorber deposited by spray pyrolysis, ZnS buffer deposited by spray ion layer gas reduction, ZnO:Ga transparent conducting oxide (TCO) deposited by sputtering, and the encapsulant polydimethylsiloxane

  2. Comparative alternative materials assessment to screen toxicity hazards in the life cycle of CIGS thin film photovoltaics

    Energy Technology Data Exchange (ETDEWEB)

    Eisenberg, Daniel A.; Yu, Mengjing; Lam, Carl W. [University of California, Davis, 1 Shields Avenue, Davis, CA 95616 (United States); Ogunseitan, Oladele A. [University of California, Irvine, Irvine, CA 92697 (United States); Schoenung, Julie M., E-mail: jmschoenung@ucdavis.edu [University of California, Davis, 1 Shields Avenue, Davis, CA 95616 (United States)

    2013-09-15

    Highlights: • Comparative alternatives assessment of thin film manufacturing technologies. • Development of chemical alternatives assessment in a life cycle context. • Screening of manufacturing and solar cell hazardous substances simultaneously. -- Abstract: Copper–indium–gallium–selenium–sulfide (CIGS) thin film photovoltaics are increasingly penetrating the market supply for consumer solar panels. Although CIGS is attractive for producing less greenhouse gas emissions than fossil-fuel based energy sources, CIGS manufacturing processes and solar cell devices use hazardous materials that should be carefully considered in evaluating and comparing net environmental benefits of energy products. Through this research, we present a case study on the toxicity hazards associated with alternative materials selection for CIGS manufacturing. We applied two numeric models, The Green Screen for Safer Chemicals™ and the Toxic Potential Indicator. To improve the sensitivity of the model outputs, we developed a novel, life cycle thinking based hazard assessment method that facilitates the projection of hazards throughout material life cycles. Our results show that the least hazardous CIGS solar cell device and manufacturing protocol consist of a titanium substrate, molybdenum metal back electrode, CuInS{sub 2} p-type absorber deposited by spray pyrolysis, ZnS buffer deposited by spray ion layer gas reduction, ZnO:Ga transparent conducting oxide (TCO) deposited by sputtering, and the encapsulant polydimethylsiloxane.

  3. Conventional renal angiography versus renal digital subtraction angiography (DSA) in the study of renovascular hypertension

    International Nuclear Information System (INIS)

    Essinger, A.; Morsier, B. de; Narbel, M.; Raimondi, S.

    1988-01-01

    A cost-benefit analysis comparing conventional renal angiography, IV and IA DSA and spot film cameras has been made in order to quantify the advantages and disadvantages of these techniques in screening for renal artery stenosis. DSA is the best modality of imaging, using very little films, easy to archive, with a spatial resolution inferior to conventional angiography but partially compensated by contrast resolution. The surface dose per image using a 512/512 matrix is two thirds less than a conventional film, giving thus an acceptable dose as long as technical personnel is well trained and thus the number of exposures is kept low. Spot film camera, due to its excellent spatial resolution, its low radiation dose and its low price, can also be used as a screening procedure but requires an arterial injection. DSA has furthermore the advantage of quantifying renal artery stenosis making future percutaneous transluminal angioplasty easier

  4. Effect of Firing Temperature on the Composition and Structural Parameters of Screen Printed ZrO2 Thick Film Sensors

    Directory of Open Access Journals (Sweden)

    S. J. PATIL

    2010-12-01

    Full Text Available The compositional, morphological and structural properties of ZrO2 thick films prepared by a standard screen printing method and fired between 800 oC to 1000 oC for 2 hours in an air atmosphere. The material characterization was done using X-ray energy dispersive analysis (EDX, X-ray diffraction (XRD and a scanning electron microscope (SEM. The deposited films were polycrystalline in nature having the monoclinic, tetragonal- cubic structure with a preferred orientation along the (1’11 plane. The result shows that the mass % of Zr was found to be 79.10, 82.14 and 82.04 % for firing temperatures of 800, 900 and 1000 0C respectively may be due to the release of excess oxygen. The effect of the firing temperature on structural parameters such as the crystallite size, percentage of phases, texture coefficient, RMSmicrostrain, dislocation density and stacking fault probability have been studied. The results indicate that grain growth can be increased by increasing the firing temperature which is responsible for decreasing the RMSmicrostrain and dislocation density in ZrO2 thick films. The stacking fault probability remains constant for all firing temperatures. The crystallite size changes from 25.71 nm to 30.80 nm with respect to the increase in the firing temperature.

  5. Screen printing as a scalable and low-cost approach for rigid and flexible thin-film transistors using separated carbon nanotubes.

    Science.gov (United States)

    Cao, Xuan; Chen, Haitian; Gu, Xiaofei; Liu, Bilu; Wang, Wenli; Cao, Yu; Wu, Fanqi; Zhou, Chongwu

    2014-12-23

    Semiconducting single-wall carbon nanotubes are very promising materials in printed electronics due to their excellent mechanical and electrical property, outstanding printability, and great potential for flexible electronics. Nonetheless, developing scalable and low-cost approaches for manufacturing fully printed high-performance single-wall carbon nanotube thin-film transistors remains a major challenge. Here we report that screen printing, which is a simple, scalable, and cost-effective technique, can be used to produce both rigid and flexible thin-film transistors using separated single-wall carbon nanotubes. Our fully printed top-gated nanotube thin-film transistors on rigid and flexible substrates exhibit decent performance, with mobility up to 7.67 cm2 V(-1) s(-1), on/off ratio of 10(4)∼10(5), minimal hysteresis, and low operation voltage (transistors (bent with radius of curvature down to 3 mm) and driving capability for organic light-emitting diode have been demonstrated. Given the high performance of the fully screen-printed single-wall carbon nanotube thin-film transistors, we believe screen printing stands as a low-cost, scalable, and reliable approach to manufacture high-performance nanotube thin-film transistors for application in display electronics. Moreover, this technique may be used to fabricate thin-film transistors based on other materials for large-area flexible macroelectronics, and low-cost display electronics.

  6. Scintillating screens based on the single crystalline films of multicomponent garnets: new achievements and possibilities

    Czech Academy of Sciences Publication Activity Database

    Zorenko, Yu.; Gorbenko, V.; Zorenko, T.; Paprocki, K.; Nikl, Martin; Mareš, Jiří A.; Bilski, P.; Twardak, A.; Sidletskiy, O.; Gerasymov, I.; Grinyov, B.; Fedorov, A.

    2016-01-01

    Roč. 63, č. 2 (2016), s. 497-502 ISSN 0018-9499 R&D Projects: GA ČR GAP204/12/0805 Institutional support: RVO:68378271 Keywords : Ce dopant * garnets * liquid phase epitaxy * luminescence * scintillators * single crystalline films Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.171, year: 2016

  7. Screen printed PZT/PZT thick film bimorph MEMS cantilever device for vibration energy harvesting

    DEFF Research Database (Denmark)

    Xu, R.; Lei, A.; Christiansen, T. L.

    2011-01-01

    We present a MEMS-based PZT/PZT thick film bimorph vibration energy harvester with an integrated silicon proof mass. The most common piezoelectric energy harvesting devices utilize a cantilever beam of a non piezoelectric material as support beneath or in-between the piezoelectric material...

  8. Comparison of the method of diffusive gels in thin films with conventional extraction techniques for evaluating zinc accumulation in plants and isopods

    International Nuclear Information System (INIS)

    Koster, Marijke; Reijnders, Lucas; Oost, Nathalie R. van; Peijnenburg, Willie J.G.M.

    2005-01-01

    The measurement of diffusive gels in thin films (DGT) has recently been developed to assess metal bioavailability in soils. The DGT-method is based on diffusion in a porous matrix. To test the predictive capabilities of the method with regard to metal bioavailability, a study was set up with 28 soils having a variety of textures and amounts of zinc salts added. Correlation and regression analyses were performed to compare DGT-extracted zinc levels to zinc concentrations obtained by extraction with 0.01 M CaCl 2 and 0.43 M HNO 3 , digestion with aqua regia and the zinc concentration in pore water. The amount of zinc extracted with CaCl 2 correlated well with DGT-extracted zinc levels in all soils spiked with different amounts of ZnCl 2 . A similar correlation was not found for zinc concentrations in soil samples collected in the field. Experiments were performed to compare zinc content in organisms and in soils. The organisms tested were plants (grass, lettuce and lupine) and the hard bodied soil dwelling isopod Oniscus asellus. Good correlations were found between zinc accumulation in grass and lettuce and the C E (effective concentration) measured by a DGT-device, CaCl 2 extracted zinc and the zinc content in the pore water of all soils. The correlation with C E was not significant for lupine, neither for spiked soils, nor for field soils (p ≤ 0.001). Zinc levels in the isopods were not significantly related to any set of zinc measurements. From a synthesis of all results obtained it is concluded that the DGT-methodology does not have an additional value in predicting bioavailability of zinc in terrestrial ecosystems as compared to conventional extraction methods. - Capsule: The newly developed method of diffusive gels in Thin films (DGT) does not have an added value over conventional extraction techniques in predicting zinc uptake by plants and isopods

  9. Images of Youth on Screen: Manipulative Translation Strategies in the Dubbing of American Teen Films

    Directory of Open Access Journals (Sweden)

    Serenella Zanotti

    2016-02-01

    Full Text Available Teen films have often been a locus of censorial intervention due to the sensitive issues that youth-centred stories most typically address, especially when it comes to the representation of family life, juvenile delinquency, violence, youth sexuality and language. This paper offers an analysis of the dubbed versions of three mainstream youth films from the 1950s, 1960s and 1970s, namely Rebel Without a Cause (Nicholas Ray, 1955, Splendor in the Grass (Elia Kazan, 1961 and The Summer of 42 (Robert Mulligan, 1971, with the aim to investigate whether the strategies adopted in their linguistic transfer were shaped by censorial concerns or by differences in the way juvenile cultures were represented locally. The study is based on documentary evidence gleaned from archival research and translator manuscript analysis (Munday 2012, 2013.

  10. Digital imaging using storage phosphor screens a film-less procedure to detect radiation

    International Nuclear Information System (INIS)

    Narayana Rao, A.V.S.S.; Mahajan, S.K.

    1998-01-01

    The imaging plate is a film-like radiation sensor comprising of specifically designed phosphors (photostimulable storage phosphors) that trap and store energy resulting from the decay of radioactive atoms in the sample. In a typical setup, samples containing radioactivity are placed next to the imaging plate for a duration of about 5-10 times less than that is needed for normal x-ray films. The stored energy is stable until scanned with a laser beam, which releases the energy as luminescence. Digital signal processing of the emitted light results in an image which represents a quantitative measure of the activity of the radiolabeled sample. This phosphor technology, launched in its first application to the medical x-ray diagnostic field, portends great promise in a wide range of newer scientific and technological applications. (author)

  11. Patient radiation dose in conventional and xerographic cephalography

    International Nuclear Information System (INIS)

    Copley, R.L.; Glaze, S.A.; Bushong, S.C.; West, D.C.

    1979-01-01

    A comparison of the radiation doses for xeroradiographic and conventional film screen cephalography was made. Alderson tissue-equivalent phantoms were used for patient simulation. An optimum technique in terms of patient dose and image quality indicated that the dose for the Xerox process ranged from five to eleven times greater than that for the conventional process for entrance and exit exposures, respectively. This dose, however, falls within an acceptable range for other dental and medical radiation doses. It is recommended that conventional cephalography be used for routine purposes and that xeroradiography be reserved for situations requiring the increased image quality that the process affords

  12. Toxicological evaluation of natural rubber films from vulcanized latex by the conventional process and the alternative process with ionizing radiation; Avaliacao toxicologica de filmes de borracha natural obtidos do latex vulcanizado pelo processo convencional e pelo processo alternativo com radiacao ionizante

    Energy Technology Data Exchange (ETDEWEB)

    Campos, Vania Elisabeth

    1997-07-01

    The industrial vulcanization of natural rubber latex (NRL) is made all over the world by conventional process using sulphur and heat but it can be made by an alternative process using ionizing radiation. In this research the NRL was tested by 13 physical, chemical and mechanical assays which showed its good quality. It was done a preliminary study of the toxicological properties of 4 natural rubber films obtained by casting process of NRL: one non vulcanized, other vulcanized by the conventional process and two vulcanized by the alternative process. In the alternative process the films were obtained by irradiation of NRL by gamma rays from the {sup 60} Co source at 250 kGy in the absence of sensitizer and irradiated NRL at 12 kGy in the presence of 4ph r of n-butyl acrylate / 0.2 phr of KOH. These vulcanization doses were determined from broken tensile strength. In the conventional process, sulphur vulcanized NRL was made using a classical composition. Another film was made with non vulcanized NRL. The preliminary evaluation of the toxicological properties was made from in vitro cytotoxicity and in vivo systemic toxicity assays. The LBN films vulcanized by the alternative process have less cytotoxicity than the NRL film vulcanized by the conventional process. The sensitized vulcanized films by gamma rays and non vulcanized films showed similar cytotoxicity while the vulcanized films without sensitizer showed a slight lower cytotoxicity. The non vulcanized NRL film and the NRL films vulcanized by the alternative process did not show toxic effects in the 72 hours period of the systemic toxicity assay. However the NRL film vulcanized with sulphur induced effects like allaying and motor in coordination on the animals treated with an oil extract at the fourth hour and recovering after that. The alternative process promoted lower toxic effects than conventional process because there was no toxic substances present. (author)

  13. A Water-Based Silver-Nanowire Screen-Print Ink for the Fabrication of Stretchable Conductors and Wearable Thin-Film Transistors.

    Science.gov (United States)

    Liang, Jiajie; Tong, Kwing; Pei, Qibing

    2016-07-01

    A water-based silver-nanowire (AgNW) ink is formulated for screen printing. Screen-printed AgNW patterns have uniform sharp edges, ≈50 μm resolution, and electrical conductivity as high as 4.67 × 10(4) S cm(-1) . The screen-printed AgNW patterns are used to fabricate a stretchable composite conductor, and a fully printed and intrinsically stretchable thin-film transistor array is also realized. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Mercury Distribution in the Deûle River (Northern France) Measured by the Diffusive Gradients in Thin Films Technique and Conventional Methods.

    Science.gov (United States)

    Diviš, Pavel; Kadlecová, Milada; Ouddane, Baghdad

    2016-05-01

    The distribution of mercury in surface water and in sediment from Deûle River in Northern France was studied by application of conventional sampling methods and by diffusive gradients in thin films technique (DGT). Concentration of total dissolved mercury in surface water was 20.8 ± 0.8 ng l(-1). The particulate mercury concentration was 6.2 ± 0.6 µg g(-1). The particulate mercury was accumulated in sediment (9.9 ± 2.3 mg kg(-1)), and it was transformed by methylating bacteria to methylmercury, mainly in the first 2-cm layer of the sediment. Total dissolved concentration of mercury in sediment pore water obtained by application of centrifugation extraction was 17.6 ± 4.1 ng l(-1), and it was comparable with total dissolved pore water mercury concentration measured by DGT probe containing Duolite GT-73 resin gel (18.2 ± 4.3 ng l(-1)), taking the sediment heterogeneity and different principles of the applied methods into account. By application of two DGT probes with different resin gels specific for mercury, it was found that approximately 30% of total dissolved mercury in sediment pore water was present in labile forms easy available for biota. The resolution of mercury DGT depth profiles was 0.5 cm, which allows, unlike conventional techniques, to study the connection of the geochemical cycle of mercury with geochemical cycles of iron and manganese.

  15. Measurements of reciprocity law failure in green-sensitive X-ray films.

    Science.gov (United States)

    Arnold, B A; Eisenberg, H; Bjärngard, B E

    1978-02-01

    Reciprocity law failure was measured for four brands of medical x-ray films exposed with intensifying screens. Three of the films are green light-sensitized for use in combination with green light-emitting rare-earth screens. These films showed larger reciprocity failure effects than one conventional blue-sensitive film, Dupont Cronex-2. Development conditions had a small effect on reciprocity failure. As part of the investigation, a detector was constructed with a response that accurately monitors the light emission from the double screen-cassette combination over a wide range of x-ray photon energies.

  16. Clamping effect on the piezoelectric responses of screen-printed low temperature PZT/Polymer films on flexible substrates

    Science.gov (United States)

    Almusallam, A.; Yang, K.; Zhu, D.; Torah, R. N.; Komolafe, A.; Tudor, J.; Beeby, S. P.

    2015-11-01

    This paper introduces a new flexible lead zirconate titanate (PZT)/polymer composite material that can be screen-printed onto fabrics and flexible substrates, and investigates the clamping effect of these substrates on the characterization of the piezoelectric material. Experimental results showed that the optimum blend of PZT/polymer binder with a weight ratio of 12:1 provides a dielectric constant of 146. The measured value of the piezoelectric coefficient d33 was found to depend on the substrate used. Measured d33clp values of 70, 40, 36 pC N-1 were obtained from the optimum formulation printed on Polyester-cotton with an interface layer, Kapton and alumina substrates, respectively. The variation in the measured d33clp values occurs because of the effect of the mechanical boundary conditions of the substrate. The piezoelectric film is mechanically bonded to the surface of the substrate and this constrains the film in the plane of the substrate (the 1-direction). This constraint means that the perpendicular forces (applied in the 3-direction) used to measure d33 introduce a strain in the 1-direction that produces a charge of the opposite polarity to that induced by the d33 effect. This is due to the negative sign of the d31 coefficient and has the effect of reducing the measured d33 value. Theoretical and experimental investigations confirm a reduction of 13%, 50% and 55% in the estimated freestanding d33fs values (80 pC N-1) on Polyester-cotton, Kapton and alumina substrates, respectively. These results demonstrate the effect of the boundary conditions of the substrate/PZT interface on the piezoelectric response of the PZT/polymer film and in particular the reduced effect of fabric substrates due to their lowered stiffness.

  17. Fabrication of Cu(In,Ga)Se2 thin films by a combination of mechanochemical and screen-printing/sintering processes

    International Nuclear Information System (INIS)

    Wada, T.; Matsuo, Y.; Nomura, S.; Nakamura, Y.; Miyamura, A.; Chiba, Y.; Konagai, M.; Yamada, A.

    2006-01-01

    We prepared fine Cu(In,Ga)Se 2 (CIGS) powder suitable for screen printing using a mechanochemical process. Particulate precursors were deposited in a thin layer by a screen-printing technique, the remaining organic solvent was removed from the screen-printed CIGS film and finally the porous precursor layer was sintered into a dense polycrystalline film by atmospheric-pressure firing. The crystal structure of the film was analyzed by X-ray diffraction and the microstructure was observed in a SEM. The thickness of the film was 5-10 μm with a grain size of about 2 μm. The films were also observed in a TEM. The grain size of the as-prepared powder was less than 1 μm; however, it enlarged to 2-3 μm after firing at 575 C under a Se ambient. Preliminary CIGS solar cells with our standard Al grid/B-doped ZnO/i-ZnO/ CdS/CIGS/Mo/soda-lime glass structure were fabricated. An efficiency of 2.7%, a V oc of 0.325 V, a J sc of 28.3 mA/cm 2 and a FF of 0.295 was obtained. (copyright 2006 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (Abstract Copyright [2006], Wiley Periodicals, Inc.)

  18. Comparison of digital selenium radiography with an analog screen-film system in the diagnostic process of pneumoconiosis according to ILO classification

    International Nuclear Information System (INIS)

    Zaehringer, M.; Winnekendonk, G.; Gossmann, A.; Krueger, K.; Krug, B.

    2001-01-01

    Purpose: The aim of the study was to determine the diagnostic value of digital selenium radiography in patients with pneumoconiosis. For this purpose chest X-rays by digital selenium radiography and analog screen-film system were compared according to the ILO classification of pneumoconiosis. Method: After approval of the study by the local ethic commission and the Federal German Office for Radiation Protection 50 patients were subjected to X-rays by digital selenium radiography (Thoravision; Philips Medical Systems, Hamburg, Germany) and analog screen-film system of the same day within the scope of an industrial medicine preventive checkup. Four investigators rated the chest X-rays according to the ILO classification of pneumoconiosis. Results: The findings demonstrated by chest X-rays according to ILO classification were rated similar by digital selenium radiography and analog screen film systems. Image quality of the digital pictures was rated significantly better. Conclusion: The use of digital selenium radiography in evaluating chest X-rays according to the ILO classification does not result in over- or underestimation of pulmonary pathologies. Hence, in the diagnosis of pneumoconiosis, digital selenium radiography can replace the tested analog screen-film system. (orig.) [de

  19. Digital luminescent radiography: A substitute for conventional chest radiography?

    International Nuclear Information System (INIS)

    Neufang, K.F.R.; Krug, B.; Lorenz, R.; Steinbrich, W.

    1990-01-01

    The image quality of digital luminescent radiography (DLR) is sufficient for routine biplane chest radiography and for follow-up studies of heart size, pulmonary congestion, coin lesions, infiltrations, atelectasis, pleural effusions, and mediastinal and hilar lymph node enlargement. Chest radiography in the intensive care unit may in most cases be performed using the DLR technique. there is no need for repeat shots because of incorrect exposure, and the position of catheters, tubes, pacemakers, drains and artificial heart valves, the mediastinum, and the retrocardiac areas of the left lung are more confidently assessed on the edge-enhanced DLR films than on conventional films. Nevertheless, DLR is somewhat inferior to conventional film-screen radiography of the chest as it can demonstrate or rule out subtle pulmonary interstitial disease less confidently. There is no reduction of radiation exposure of the chest in DLR compared with modern film-screen systems. As a consequence, DLR is presently not in a position to replace traditional film-screen radiography of the chest completely. (orig.) [de

  20. Performance of ultralow-dose CT with iterative reconstruction in lung cancer screening: limiting radiation exposure to the equivalent of conventional chest X-ray imaging

    Energy Technology Data Exchange (ETDEWEB)

    Huber, Adrian [University Hospital Inselspital Bern, Department of Diagnostic, Interventional and Paediatric Radiology, Bern (Switzerland); University Hospital Pitie-Salpetriere, Department of Polyvalent and Oncological Radiology, Paris (France); Landau, Julia; Buetikofer, Yanik; Leidolt, Lars; Brela, Barbara; May, Michelle; Heverhagen, Johannes; Christe, Andreas [University Hospital Inselspital Bern, Department of Diagnostic, Interventional and Paediatric Radiology, Bern (Switzerland); Ebner, Lukas [University Hospital Inselspital Bern, Department of Diagnostic, Interventional and Paediatric Radiology, Bern (Switzerland); Duke University Medical Center, Department of Radiology, Durham, NC (United States)

    2016-10-15

    To investigate the detection rate of pulmonary nodules in ultralow-dose CT acquisitions. In this lung phantom study, 232 nodules (115 solid, 117 ground-glass) of different sizes were randomly distributed in a lung phantom in 60 different arrangements. Every arrangement was acquired once with standard radiation dose (100 kVp, 100 references mAs) and once with ultralow radiation dose (80 kVp, 6 mAs). Iterative reconstruction was used with optimized kernels: I30 for ultralow-dose, I70 for standard dose and I50 for CAD. Six radiologists examined the axial 1-mm stack for solid and ground-glass nodules. During a second and third step, three radiologists used maximum intensity projection (MIPs), finally checking with computer-assisted detection (CAD), while the others first used CAD, finally checking with the MIPs. The detection rate was 95.5 % with standard dose (DLP 126 mGy*cm) and 93.3 % with ultralow-dose (DLP: 9 mGy*cm). The additional use of either MIP reconstructions or CAD software could compensate for this difference. A combination of both MIP reconstructions and CAD software resulted in a maximum detection rate of 97.5 % with ultralow-dose. Lung cancer screening with ultralow-dose CT using the same radiation dose as a conventional chest X-ray is feasible. (orig.)

  1. Digitization of conventional radiographs

    International Nuclear Information System (INIS)

    Wenz, W.; Buitrago-Tellez, C.; Blum, U.; Hauenstein, K.H.; Gufler, H.; Meyer, E.; Ruediger, K.

    1992-01-01

    The diagnostic value of a digitization system for analogue films based on a charge-coupled-device (CCD) scanner with adjustable resolution of 2.5 or 5 lp/mm was assessed. Some 110 skeletal radiographs, 50 contrast studies, including 25 of patients with Crohn's disease, and 70 abdominal plain films before and after successful lithotripsy for renal stones were digitized. Receiver operating characteristic (ROC) studies showed improved detection of cortical and trabecular defects with contrast-optimized digitized films. Edge enhancement algorithms yielded no additional information. Inflammatory lesions of Crohn's disease were detected equally well by conventional films and digitized images. A statistically significant improvement (p [de

  2. Large-image intensifier photofluorography and conventional radiography in pulmonary emphysema

    International Nuclear Information System (INIS)

    Manninen, H.; Partanen, K.; Soimakallio, S.; Rytkoenen, H.

    1988-01-01

    Large-screen image intensifier (II) photofluorography was compared with full-size screen-film chest radiography in the diagnosis of pulmonary emphysema in 84 patients. Photospot films and conventional radiographs were interpreted independently by three radiologists. Computed tomography (CT) was used as an independent reference technique, and diagnostic performance of chest radiography in various CT patterns of emphysema was evaluated. The difference in diagnostic sensitivity for emphysema in favor of conventional chest radiography over photofluorography (0.65 versus 0.56) was statistically significant (p < 0.05). Specificity of the imaging modalities was equal: 0.78 in full-size films and 0.77 in photospot films. All CT patterns of emphysema had great false negative response rates in chest radiography, which is an inaccurate technique for the diagnosis of emphysema. CT is required for reliable radiologic evaluation of emphysema. (orig.)

  3. Design and Construction of a Test Phantom for Screen/Film Mammography Quality Control

    International Nuclear Information System (INIS)

    Galvan, Hector; Grabski, Varlen; Ruiz, Cesar; Brandan, Maria-Ester; Villasenor, Yolanda

    2006-01-01

    A 10 x 10 x 4 cm Lucite phantom for quality control tests in mammography has been designed and built. It contains internal elements to quantify contrast and resolution, a mixture of talc and Lucite fibers to simulate the breast architecture, a 9-step aluminum wedge to verify the constancy of the film developing process, and metallic foils to evaluate kVp. Associated with an ionization chamber, the mean glandular dose can be evaluated. Its performance has been compared against the phantom accredited by the American College of Radiology. For a series of kV, both phantoms OD are similar within 5%. The step wedge can detect developer temperature changes of ±1 deg. C. Relative metal foils/acrylic OD permits to calculate kVp with precision of ±0.43 kV. Radiological measurements have been interpreted by numerical calculations

  4. Sensitometry of intensifying screen-film system for detection of yearly change of imaging quality factors

    International Nuclear Information System (INIS)

    Yoshida, Akira; Asahara, Masayoshi

    2002-01-01

    Systematic sensitometry of 20 green- and 25 blue-intensifying screens made in early 1980s and early 1990s was performed on their physical imaging qualities to evaluate their yearly change. Sensitometry was done with Toshiba KXO-1000 X-ray generator (Tube: Toshiba DRX-431HD, 80 kV, 20 mm-thick Al-filter), characteristic curve examination with KXO-15 (Tube: DRX-1603B, 80 kV, 0.5 mm Cu+4.0 mm Al), determination of modulation transfer function with KXO-15 (Tube: DRX-1303B, 80 kV, 2.0 mm Al), and Wiener spectrometry with Hitachi DH-158 (Tube: Hitachi UH-6GC-108DL, 80 kV, 20 mmAl). Reference screen was that reported by US Bureau of Radiological Health (1982) and Center for Devices and Radiological Health (196) and was obtained from Chicago University. There were products without yearly change, with increased sensitivity with unchanged resolution and noise level, with improved resolution, or with improved sensitivity. (K.H.)

  5. Digital chest radiography system with amorphous selenium flat-panel detectors: qualitative and dosimetric comparison with a dedicated film-screen system

    International Nuclear Information System (INIS)

    Prato, Antonio; Fava Cesare; Ropolo, Roberto

    2005-01-01

    Purpose. To compare the quality and radiation dose of a conventional film-screen system and a digital system with amorphous selenium detectors in the study of the chest, by verifying overall performance and exposure levels for the main chest structures in patients of different sizes. Materials and methods. An analogic system (Chest Changer, Dupont, Day-light model 1000) and a digital system (Directray Rad 1000C, Hologic) were tested on a total of 1000 patients randomly assigned to one of two groups of 500 subjects.The patients were further subdivided according to BMI (Body Mass Index). Image quality was determined by two chest radiologists who evaluated eight anatomical structures. The entrance surface dose (skin-dose), calculated based on the exposure parameters, was taken as the patient dose. Results. Mean dose delivered was very similar for both techniques in the PA view (0.28 mGy), but it was greater in the LL projections obtained with the digital system (1.20 rnGy versus 0.83 mGy). The highest overall scores were assigned to 43% and 23.2% analogic radiograms and 64% and 70.2% digital radiograms, for the PA and LL projections respectively. The scores assigned to the various anatomical structures confirmed the better performance of the digital system in almost all of the regions considered. Conclusions. The mean quality of radiograms is definitely higher with the digital system, in particular in the LL projections, where the higher patient doses are counterbalanced by fewer repeated scans. The greater level of exposure in the digital system appears nonetheless tolerable on account of the greater informativeness and therefore diagnostic gain and also considering the possibilities for improving the system [it

  6. Comparison of the method of diffusive gels in thin films with conventional extraction techniques for evaluating zinc accumulation in plants and isopods

    Energy Technology Data Exchange (ETDEWEB)

    Koster, Marijke [National Institute of Public Health and the Environment, Laboratory for Ecological Risk Assessment, P.O. Box 1, 3720 BA Bilthoven (Netherlands); Open University Netherlands, Heerlen (Netherlands); Reijnders, Lucas [Open University Netherlands, Heerlen (Netherlands); Oost, Nathalie R. van [National Institute of Public Health and the Environment, Laboratory for Ecological Risk Assessment, P.O. Box 1, 3720 BA Bilthoven (Netherlands); Peijnenburg, Willie J.G.M. [National Institute of Public Health and the Environment, Laboratory for Ecological Risk Assessment, P.O. Box 1, 3720 BA Bilthoven (Netherlands)]. E-mail: wjgm.peijnenburg@rivm.nl

    2005-01-01

    The measurement of diffusive gels in thin films (DGT) has recently been developed to assess metal bioavailability in soils. The DGT-method is based on diffusion in a porous matrix. To test the predictive capabilities of the method with regard to metal bioavailability, a study was set up with 28 soils having a variety of textures and amounts of zinc salts added. Correlation and regression analyses were performed to compare DGT-extracted zinc levels to zinc concentrations obtained by extraction with 0.01 M CaCl{sub 2} and 0.43 M HNO{sub 3}, digestion with aqua regia and the zinc concentration in pore water. The amount of zinc extracted with CaCl{sub 2} correlated well with DGT-extracted zinc levels in all soils spiked with different amounts of ZnCl{sub 2}. A similar correlation was not found for zinc concentrations in soil samples collected in the field. Experiments were performed to compare zinc content in organisms and in soils. The organisms tested were plants (grass, lettuce and lupine) and the hard bodied soil dwelling isopod Oniscus asellus. Good correlations were found between zinc accumulation in grass and lettuce and the C{sub E} (effective concentration) measured by a DGT-device, CaCl{sub 2} extracted zinc and the zinc content in the pore water of all soils. The correlation with C{sub E} was not significant for lupine, neither for spiked soils, nor for field soils (p {<=} 0.001). Zinc levels in the isopods were not significantly related to any set of zinc measurements. From a synthesis of all results obtained it is concluded that the DGT-methodology does not have an additional value in predicting bioavailability of zinc in terrestrial ecosystems as compared to conventional extraction methods. - Capsule: The newly developed method of diffusive gels in Thin films (DGT) does not have an added value over conventional extraction techniques in predicting zinc uptake by plants and isopods.

  7. High T/sub c/ screen-printed YBa2Cu3O/sub 7-//sub x/ films: Effect of the substrate material

    International Nuclear Information System (INIS)

    Bansal, N.P.; Simons, R.N.; Farrell, D.E.

    1988-01-01

    Thick films of YBa 2 Cu 3 O/sub 7-//sub x/ have been deposited on highly polished alumina, magnesia spinel, nickel aluminum titanate (Ni-Al-Ti), and barium tetratitanate (Ba-Ti) substrates by the screen printing technique. They were baked at 1000 0 C for 15 min, oxygen annealed at a lower temperature, and characterized by electrical resistivity measurements, x-ray diffraction, and optical and scanning electron microscopy. Properties of the films were found to be highly sensitive to the choice of the substrate material. The film on Ba-Ti turned green after firing, due to a reaction with the substrate and were insulating. A film on Ni-Al-Ti had a T/sub c/ (onset) ∼95 K and lost 90% of its resistance by ∼75 K. However, even at 4 K it was not fully superconducting, possibly due to a reaction between the film and the substrate and interdiffusion of the reaction products. The film on alumina had T/sub c/ (onset) ∼96 K, T/sub c/ (zero) ∼66 K, and ΔT/sub c/ (10--90%) ∼10 K. Our best film was obtained on spinel and had T/sub c/ (onset) ∼94 K, zero resistance at 81 K, and a transition width (10--90%) of ∼7 K

  8. Impedance Based Characterization of a High-Coupled Screen Printed PZT Thick Film Unimorph Energy Harvester

    DEFF Research Database (Denmark)

    Lei, Anders; Xu, R.; Borregaard, L. M.

    2014-01-01

    The single degree of freedom mass-spring-damper system is the most common approach for deriving a full electromechanical model for the piezoelectric vibration energy harvester. In this paper, we revisit this standard electromechanical model by focusing on the impedance of the piezoelectric device...... parameters which, by means of the piezoelectric impedance expression, all can be determined accurately by electrical measurements. It is shown how four of five lumped parameters can be determined from a single impedance measurement scan, considerably reducing the characterization effort. The remaining...... parameter is determined from shaker measurements, and a highly accurate agreement is found between model and measurements on a unimorph MEMS-based screen printed PZT harvester. With a high coupling term K-2 Q similar or equal to 7, the harvester exhibits two optimum load points. The peak power performance...

  9. Assessment of dose to patients undergoing computed radiography and film screen x-ray examinations in some Khartoum Hospitals

    International Nuclear Information System (INIS)

    Mohamed Khair, Haiffa Daffa Allah Mustafa

    2015-12-01

    Medical ionizing radiation sources give by far the largest contribution to the population dose from man made sources and most of the contribution comes from diagnostic x-rays. The optimization principle of radiation protection requires the minimization of radiation dose to patients while acquiring diagnostic quality images in radiology. In radiography, the extent of patient dose reduction is limited by the characteristics of the system used and the quality (or penetrating ability) of the x-ray beam. In this study, the entrance surface air kerma doses (ESA Ks) to patients undergoing 7 selected x-ray examinations were estimated. The study was conducted in eight hospitals in Khartoum State, comprising nine x-ray units and a total of 1200 patients were involved. Four of the hospitals involved in this study use computed radiography (CR) technology while the other four use film screen (FS) technology. The selected examinations were, abdomen (AP), chest (PA), pelvis (AP), skull (AP/PA), skull (LAT), thoracic spine (AP) and thoracic spine (LAT). The entrance surface air kerma was calculated by two methods, utilizing software CAL Dose X-3.5 and a mathematical model. Average ESAK values calculated using the two methods for hospitals using (CR) technology in mGy were 2.99 and 2.98, 0.34 and 0.31, 2.79 and 2.58, 0.76 and 0.71, 0.94 and 0.79, 3.4 and 3,2 and 5.9 and 5.03, for the above mentioned selected investigations respectively. And average ESAK values calculated using two methods for hospital using FS technology in mGy were found 4.98 and 4.19, 0.37 and 0.34, 4.15 and 3.95, 2.2 and 2. 1.3 and 1.1, 3.9 and 3.9, 9.4 and 8.3 for the above mentioned selected investigations respectively. Average ESAK values obtained by two methods for FS were higher values than the obtained by CR by 37 and 29%, 50 and 25%, 8%, 32 and 34%, 65 and 64%, 27 and 28%, 12% and 73% and 39% for the above mentioned selected investigations, respectively. This shows that CR technique allows diagnostically

  10. Digital luminescence radiography and conventional radiography in abdominal contrast examinations

    International Nuclear Information System (INIS)

    Krug, B.; Harnischmacher, U.; Krahe, T.; Fischbach, R.; Altenburg, A.; Krings, F.

    1995-01-01

    In 326 patients abdominal contrast radiographs were compared to digital luminescence radiographs (DLR) and conventional screen-film system ones. The digital exposure dose was 50% of the conventional. In DLR, 2 different types of postprocessed images were obtained from each data set. A display with low spatial frequency enhancement filtered to look like a conventional radiograph was compared to a display with high spatial frequency enhancement. Conventional and DLR images were evaluated randomly and separately by 4 radiologists by means of a questionnaire. DLR proved to be diagnostically equivalent to the conventional technique with the exception of a slightly diminished visibility of the mucosal pattern. High spatial frequency enhancement did not provide additional diagnostic information and should be dispensed with in abdominal examinations. (orig.)

  11. Comparing the visualization of microcalcifications with direct magnification in digital full-field mammography vs. film-screen mammography

    International Nuclear Information System (INIS)

    Diekmann, F.; Diekmann, S.; Rogalla, P.; Hamm, B.; Bick, U.; Blohmer, J.U.; Winzer, K.J.

    2002-01-01

    Purpose: To evaluate the conspicuity of microcalcifications in magnified mammographic views of preparations obtained with full field digital mammography (FFDM), film-screen mammography (FSM), and the DIMA technique. Material and Methods: Twelve preparations were examined by FFDM and FSM using 1.8 x magnification and DIMA using 7 x magnification. Parameter settings were identical for all three techniques. The number of visible microcalcifications was then determined for each modality by three radiologists. As far as possible, all preparations were X-rayed at 22 kV and 10 mAS. Results: Altogether 9705 calcifications were counted (DIMA: 1609/1542/1534; FFDM: 1020/753/881; FSM: 901/643/822). The total number of microcalcifications identified with the DIMA technique was 4685 as compared to 2654 with FFDM and 2366 with FSM. The calcifications counted with FFDM and FSM thus corresponded to 56.6% and 50.5%, respectively, of those identified with DIMA. The differences between the groups were statistically significant (F-Test, p [de

  12. Peroxynitrite Sensor Based on a Screen Printed Carbon Electrode Modified with a Poly(2,6-dihydroxynaphthalene Film

    Directory of Open Access Journals (Sweden)

    Ioana Silvia Hosu

    2016-11-01

    Full Text Available For the first time the electropolymerization of 2,6-dihydroxynaphthalene (2,6-DHN on a screen printed carbon electrode (SPCE was investigated and evaluated for peroxynitrite (PON detection. Cyclic voltammetry was used to electrodeposit the poly(2,6-DHN on the carbon electrode surface. The surface morphology and structure of poly(2,6-DHN film were investigated by SEM and FTIR analysis, and the electrochemical features by cyclic voltammetry. The poly(2,6-DHN/SPCE sensor showed excellent electrocatalytic activity for PON oxidation in alkaline solutions at very low potentials (0–100 mV vs. Ag/AgCl pseudoreference. An amperometric FIA (flow injection analysis system based on the developed sensor was optimized for PON measurements and a linear concentration range from 2 to 300 μM PON, with a LOD of 0.2 μM, was achieved. The optimized sensor inserted in the FIA system exhibited good sensitivity (4.12 nA·μM−1, selectivity, stability and intra-/inter-electrode reproducibility for PON determination.

  13. Computer-aided detection of masses in full-field digital mammography using screen-film mammograms for training

    International Nuclear Information System (INIS)

    Kallenberg, Michiel; Karssemeijer, Nico

    2008-01-01

    It would be of great value when available databases of screen-film mammography (SFM) images can be used to train full-field digital mammography (FFDM) computer-aided detection (CAD) systems, as compilation of new databases is costly. In this paper, we investigate this possibility. Firstly, we develop a method that converts an FFDM image into an SFM-like representation. In this conversion method, we establish a relation between exposure and optical density by simulation of an automatic exposure control unit. Secondly, we investigate the effects of using the SFM images as training samples compared to training with FFDM images. Our FFDM database consisted of 266 cases, of which 102 were biopsy-proven malignant masses and 164 normals. The images were acquired with systems of two different manufacturers. We found that, when we trained our FFDM CAD system with a small number of images, training with FFDM images, using a five-fold crossvalidation procedure, outperformed training with SFM images. However, when the full SFM database, consisting of 348 abnormal cases (including 204 priors) and 810 normal cases, was used for training, SFM training outperformed FFDMA training. These results show that an existing CAD system for detection of masses in SFM can be used for FFDM images without retraining.

  14. Comparative alternative materials assessment to screen toxicity hazards in the life cycle of CIGS thin film photovoltaics.

    Science.gov (United States)

    Eisenberg, Daniel A; Yu, Mengjing; Lam, Carl W; Ogunseitan, Oladele A; Schoenung, Julie M

    2013-09-15

    Copper-indium-gallium-selenium-sulfide (CIGS) thin film photovoltaics are increasingly penetrating the market supply for consumer solar panels. Although CIGS is attractive for producing less greenhouse gas emissions than fossil-fuel based energy sources, CIGS manufacturing processes and solar cell devices use hazardous materials that should be carefully considered in evaluating and comparing net environmental benefits of energy products. Through this research, we present a case study on the toxicity hazards associated with alternative materials selection for CIGS manufacturing. We applied two numeric models, The Green Screen for Safer Chemicals and the Toxic Potential Indicator. To improve the sensitivity of the model outputs, we developed a novel, life cycle thinking based hazard assessment method that facilitates the projection of hazards throughout material life cycles. Our results show that the least hazardous CIGS solar cell device and manufacturing protocol consist of a titanium substrate, molybdenum metal back electrode, CuInS₂ p-type absorber deposited by spray pyrolysis, ZnS buffer deposited by spray ion layer gas reduction, ZnO:Ga transparent conducting oxide (TCO) deposited by sputtering, and the encapsulant polydimethylsiloxane. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. A prospective clinical trial to compare the performance of dried blood spots prenatal screening for Down's syndrome with conventional non-invasive testing technology.

    Science.gov (United States)

    Hu, Huiying; Jiang, Yulin; Zhang, Minghui; Liu, Shanying; Hao, Na; Zhou, Jing; Liu, Juntao; Zhang, Xiaojin; Ma, Liangkun

    2017-03-01

    To evaluate, side by side, the efficiency of dried blood spots (DBSs) against serum screening for Down's syndrome, and then, to construct a two-tier strategy by topping up the fetal cell-free DNA (cfDNA) secondary screening over the high-risk women marked by the primary blood testing to build a practical screening tactic to identify fetal Down's syndrome. One thousand eight hundred and thirty-seven low-risk Chinese women, with singleton pregnancy, were enrolled for the study. Alpha-fetoprotein and free beta human chorionic gonadotropin were measured for the serum as well as for the parallel DBS samples. Partial high-risk pregnant women identified by primary blood testing (n = 38) were also subject to the secondary cfDNA screening. Diagnostic amniocentesis was utilized to confirm the screening results. The true positive rate for Down's syndrome detection was 100% for both blood screening methods; however, the false-positive rate was 3.0% for DBS and 4.0% for serum screening, respectively. DBS correlated well with serum screening on Down's syndrome detection. Three out of 38 primary high-risk women displayed chromosomal abnormalities by cfDNA analysis, which were confirmed by amniocentesis. Either the true detection rate or the false-positive rate for Down's syndrome between DBS and the serum test is comparable. In addition, blood primary screening aligned with secondary cfDNA analysis, a "before and after" two-tier screening strategy, can massively decrease the false-positive rate, which, then, dramatically reduces the demand for invasive diagnostic operation. Impact statement Children born with Down's syndrome display a wide range of mental and physical disability. Currently, there is no effective treatment to ease the burden and anxiety of the Down's syndrome family and the surrounding society. This study is to evaluate the efficiency of dried blood spots against serum screening for Down's syndrome and to construct a two-tier strategy by topping up the fetal

  16. A New Development in the Method of Measurement of Reciprocity-Law Failure and Its Application to Screen/Green-Sensitive X-Ray Film Systems

    Science.gov (United States)

    Fujita, Hiroshi; Uchida, Suguru

    1981-01-01

    Since it has been confirmed by experiment that the intensity of X-rays varies approximately as the focus-film distance (FFD) to the minus 2.12th power, the X-ray intensity can be changed by varying the FFD. It is shown in this paper that two types of reciprocity failure curve, density vs. exposure time for constant exposure and relative exposure vs. exposure time for constant density, can easily be obtained from several time-scale characteristic curves taken experimentally for several FFD’s in the rare-earth screen-film systems used. Only low-intensity reciprocity failure is present for exposure times of more than about 0.1 sec for one film, but both low-intensity and high-intensity reciprocity failures occur in the other one. The effects of reciprocity failure on the H & D curves can be seen in the shape of the curves and the relative speed.

  17. A new development in the method of measurement of reciprocity-law failure and its application to screen/green-sensitive x-ray film systems

    International Nuclear Information System (INIS)

    Fujita, Hiroshi; Uchida, Suguru.

    1981-01-01

    Since it has been confirmed by experiment that the intensity of X-rays varies approximately as the focus-film distance (FFD) to the minus 2.12th power, the X-ray intensity can be changed by varying the FFD. It is shown in this paper that two types of reciprocity failure curve, density vs. exposure time for constant exposure and relative exposure vs. exposure time for constant density, can easily be obtained from several time-scale characteristic curves taken experimentally for several FFD's in the rare-earth screen-film systems used. Only low-intensity reciprocity failure is present for exposure times of more than about 0.1 sec for one film, but both low-intensity and high-intensity reciprocity failures occur in the other one. The effects of reciprocity failure on the H D curves can be seen in the shape of the relative speed. (author)

  18. Stripping chronopotentiometric measurements of lead(II) and cadmium(II) in soils extracts and wastewaters using a bismuth film screen-printed electrode assembly

    Energy Technology Data Exchange (ETDEWEB)

    Kadara, Rashid O.; Tothill, Ibtisam E. [Cranfield Biotechnology Centre, Cranfield University, MK45 4DT, Silsoe, Bedfordshire (United Kingdom)

    2004-02-01

    The key to remediative processes is the ability to measure toxic contaminants on-site using simple and cheap sensing devices, which are field-portable and can facilitate more rapid decision-making. A three-electrode configuration system has been fabricated using low-cost screen-printing (thick-film) technology and this coupled with a portable electrochemical instrument has provided a a relatively inexpensive on-site detector for trace levels of toxic metals. The carbon surface of the screen-printed working electrode is used as a substrate for in situ deposition of a metallic film of bismuth, which allows the electrochemical preconcentration of metal ions. Lead and cadmium were simultaneously detected using stripping chronopotentiometry at the bismuth film electrode. Detection limits of 8 and 10 ppb were obtained for cadmium(II) and lead(II), respectively, for a deposition time of 120 s. The developed method was applied to the determination of lead and cadmium in soils extracts and wastewaters obtained from polluted sites. For comparison purposes, a mercury film electrode and ICP-MS were also used for validation. (orig.)

  19. Optimization of Radiological Protection in Pediatric Patients Undergoing Common Conventional Radiological Procedures: Effectiveness of Increasing the Film to Focus Distance (FFD

    Directory of Open Access Journals (Sweden)

    Vahid Karami

    2017-04-01

    Full Text Available Background Increasing the x-ray film to focus distance (FFD, has been recommended as a practical dose optimization tool for patients undergoing conventional radiological procedures. In the previous study, we demonstrated a 32% reduction in absorbed dose is achievable due to increasing the FFD from 100 to 130 cm during pediatric chest radiography. The aim of this study was to examine whether increasing the FFD from 100 to 130 cm is equally effective for other common radiological procedures and performing a literature review of published studies to address the feasibility and probable limitations against implementing this optimization tool in clinical practice. Materials and Methods Radiographic examination of the pelvis (AP view, abdomen (AP view, skull (AP and lateral view, and spine (AP and lateral view, were taken of pediatric patients. The radiation dose and image quality of a radiological procedure is measured in FFD of 100 cm (reference FFD and 130 cm (increased FFD. The thermo-luminescent dosimeters (TLD were used for radiation dose measurements and visual grading analysis (VGA for image quality assessments. Results: Statistically significant reduction in the ESD ranged from 21.91% for the lateral skull projection to 35.24% for the lateral spine projection was obtained, when the FFD was increased from 100 to 130 cm (P0.05. Conclusion Increasing the FFD from 100 to 130 cm has significantly reduced radiation exposure without affecting on image quality. Our findings are commensurate with the literatures and emphasized that radiographers should learn to use of an updated reference FFD of 130 cm in clinical practice.

  20. Imaging characteristics of different mammographic screens.

    Science.gov (United States)

    Kuhn, H; Knüpfer, W

    1992-01-01

    A study of mammography systems with green-emitting screens was conducted to determine how the image quality parameters (apart from dose requirement), such as modulation transfer function (MTF) and Wiener spectrum (WS), depend on the dye content of the compound and coating weight of the screen. In addition, the contribution to total noise of the individual components, i.e., film, screen, and quantum noise, was studied. The quantities derived from MTF and WS, namely detective quantum efficiency (DQE) and noise equivalent quanta (NEQ), were also investigated in regard to their dose dependency. It can be demonstrated that the MTF of the screens becomes more favorable when the dye content is increased, while noise is not significantly affected. This suggests the use of a mammography screen capable of greater detail recognition, requiring at least double the dose of today's conventional systems with approximately 80 microGy system dose. On the other hand, the manufacture of a screen with about 60% of the dose of the conventional system is possible with very little loss in image quality. For the systems in common use today (80 microGy), quantum noise represents a considerable share of the total noise at low spatial frequencies, whereas in high spatial frequencies, the graininess of the film dominates quantum noise and screen structure.

  1. Large scale, highly conductive and patterned transparent films of silver nanowires on arbitrary substrates and their application in touch screens

    International Nuclear Information System (INIS)

    Madaria, Anuj R; Kumar, Akshay; Zhou Chongwu

    2011-01-01

    The application of silver nanowire films as transparent conductive electrodes has shown promising results recently. In this paper, we demonstrate the application of a simple spray coating technique to obtain large scale, highly uniform and conductive silver nanowire films on arbitrary substrates. We also integrated a polydimethylsiloxane (PDMS)-assisted contact transfer technique with spray coating, which allowed us to obtain large scale high quality patterned films of silver nanowires. The transparency and conductivity of the films was controlled by the volume of the dispersion used in spraying and the substrate area. We note that the optoelectrical property, σ DC /σ Op , for various films fabricated was in the range 75-350, which is extremely high for transparent thin film compared to other candidate alternatives to doped metal oxide film. Using this method, we obtain silver nanowire films on a flexible polyethylene terephthalate (PET) substrate with a transparency of 85% and sheet resistance of 33 Ω/sq, which is comparable to that of tin-doped indium oxide (ITO) on flexible substrates. In-depth analysis of the film shows a high performance using another commonly used figure-of-merit, Φ TE . Also, Ag nanowire film/PET shows good mechanical flexibility and the application of such a conductive silver nanowire film as an electrode in a touch panel has been demonstrated.

  2. Large scale, highly conductive and patterned transparent films of silver nanowires on arbitrary substrates and their application in touch screens.

    Science.gov (United States)

    Madaria, Anuj R; Kumar, Akshay; Zhou, Chongwu

    2011-06-17

    The application of silver nanowire films as transparent conductive electrodes has shown promising results recently. In this paper, we demonstrate the application of a simple spray coating technique to obtain large scale, highly uniform and conductive silver nanowire films on arbitrary substrates. We also integrated a polydimethylsiloxane (PDMS)-assisted contact transfer technique with spray coating, which allowed us to obtain large scale high quality patterned films of silver nanowires. The transparency and conductivity of the films was controlled by the volume of the dispersion used in spraying and the substrate area. We note that the optoelectrical property, σ(DC)/σ(Op), for various films fabricated was in the range 75-350, which is extremely high for transparent thin film compared to other candidate alternatives to doped metal oxide film. Using this method, we obtain silver nanowire films on a flexible polyethylene terephthalate (PET) substrate with a transparency of 85% and sheet resistance of 33 Ω/sq, which is comparable to that of tin-doped indium oxide (ITO) on flexible substrates. In-depth analysis of the film shows a high performance using another commonly used figure-of-merit, Φ(TE). Also, Ag nanowire film/PET shows good mechanical flexibility and the application of such a conductive silver nanowire film as an electrode in a touch panel has been demonstrated.

  3. Computed and conventional chest radiography: a comparison of image quality and radiation dose

    International Nuclear Information System (INIS)

    Ramli, K.; Abdullah, B.J.J.; Ng, K-H.; Hussain, A.F.; Mahmud, R.

    2005-01-01

    The aim of this study was to compare the image quality and entrance skin dose (ESD) for film-screen and computed chest radiography. Analysis of the image quality and dose on chest radiography was carried out on a conventional X-ray unit using film-screen, storage phosphor plates and selenium drum direct chest radiography. For each receptor, ESD was measured in 60 patients using thermoluminescent dosemeters. Images were printed on 35 x 43 cm films. Image quality was assessed subjectively by evaluation of anatomic features and estimation of the image quality, following the guidelines established by the protocols of the Commission of the European Communities. There was no statistically significant difference noted between the computed and conventional images (Wilcoxon rank sum test, P>0.05). Imaging of the mediastinum and peripheral lung structures were better visualized with the storage phosphor and selenium drum technique than with the film-screen combination. The patients' mean ESD for chest radiography using the storage phosphor, film-screen combination and selenium drum was 0.20, 0.20 and 0.25 mGy, respectively, with no statistically significant difference with P > 0.05 (χ 2 tests) Copyright (2005) Blackwell Publishing Asia Pty Ltd

  4. Method of duplicating film using the CR system. Evaluation of detectability in a simulated nodule

    International Nuclear Information System (INIS)

    Fukuyama, Atsushi; Ando, Satoshi; Maeda, Kayoko; Ida, Kazushi; Suzuki, Tomoaki; Fukuyama, Kouichi; Hasegawa, Takeo

    2005-01-01

    Since film processors used for screen-film systems have been decreasing recently, it is becoming difficult to develop duplicating film (Dup film) used conventionally. The purpose of this study was to evaluate the usefulness of the method of duplicating film using a computed radiography (CR) system. The process of duplicating film using CR is to eliminate energy accumulated on the imaging plate (IP) using white light, to accumulate energy on the whole surface, and to place the original film in piles. After an exposure of white light, duplicated films can be obtained by CR system. In order to evaluate the reproducibiliy of our system, duplicated films were read by experienced observers and receiver operating characteristic (ROC) analysis was carried out. Observers read 50 images with a simulated nodule and 50 images without a simulated nodule. The average Az values were 0.94 for the original films, 0.91 for films duplicated using Dup film, and 0.90 for films duplicated using the CR system. When the two-tailed paired-T test was performed for each result, there were no statistically significant differences at p<0.05. The detectability of a simulated nodule for films duplicated using the CR system did not differ from the detectability of films duplicated using Dup film. This method may be a reasonable substitute for the conventional duplication system. (author)

  5. Digital mammography in a screening programme and its implications for pathology: a comparative study.

    LENUS (Irish Health Repository)

    Feeley, Linda

    2011-03-01

    Most studies comparing full-field digital mammography (FFDM) with conventional screen-film mammography (SFM) have been radiology-based. The pathological implications of FFDM have received little attention in the literature, especially in the context of screening programmes. The primary objective of this retrospective study is to compare FFDM with SFM in a population-based screening programme with regard to a number of pathological parameters.

  6. An international review of the main cost-effectiveness drivers of virtual colonography versus conventional colonoscopy for colorectal cancer screening: is the tide changing due to adherence?

    Science.gov (United States)

    Kriza, Christine; Emmert, Martin; Wahlster, Philip; Niederländer, Charlotte; Kolominsky-Rabas, Peter

    2013-11-01

    The majority of recent cost-effectiveness reviews concluded that computerised tomographic colonography (CTC) is not a cost-effective colorectal cancer (CRC) screening strategy yet. The objective of this review is to examine cost-effectiveness of CTC versus optical colonoscopy (COL) for CRC screening and identify the main drivers influencing cost-effectiveness due to the emergence of new research. A systematic review was conducted for cost-effectiveness studies comparing CTC and COL as a screening tool and providing outcomes in life-years saved, published between January 2006 and November 2012. Nine studies were included in the review. There was considerable heterogeneity in modelling complexity and methodology. Different model assumptions and inputs had large effects on resulting cost-effectiveness of CTC and COL. CTC was found to be dominant or cost-effective in three studies, assuming the most favourable scenario. COL was found to be not cost effective in one study. CTC has the potential to be a cost-effective CRC screening strategy when compared to COL. The most important assumptions that influenced the cost-effectiveness of CTC and COL were related to CTC threshold-based reporting of polyps, CTC cost, CTC sensitivity for large polyps, natural history of adenoma transition to cancer, AAA parameters and importantly, adherence. There is a strong need for a differential consideration of patient adherence and compliance to CTC and COL. Recent research shows that laxative-free CTC screening has the potential to become a good alternative screening method for CRC as it can improve patient uptake of screening. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  7. An international review of the main cost-effectiveness drivers of virtual colonography versus conventional colonoscopy for colorectal cancer screening: Is the tide changing due to adherence?

    Energy Technology Data Exchange (ETDEWEB)

    Kriza, Christine, E-mail: Christine.kriza@uk-erlangen.de [Interdisciplinary Centre for Health Technology Assessment and Public Health, University of Erlangen-Nuremberg, National BMBF-Cluster of Excellence, “Medical Technologies - Medical Valley EMN”, Schwabachanlage 6, 91054 Erlangen (Germany); Emmert, Martin, E-mail: Martin.Emmert@fau.de [School of Business and Economics, Institute of Management, University of Erlangen-Nuremberg, Lange Gasse 20, 90403 Nuremberg (Germany); Wahlster, Philip, E-mail: Philip.wahlster@uk-erlangen.de [Interdisciplinary Centre for Health Technology Assessment and Public Health, University of Erlangen-Nuremberg, National BMBF-Cluster of Excellence, “Medical Technologies - Medical Valley EMN”, Schwabachanlage 6, 91054 Erlangen (Germany); Niederländer, Charlotte, E-mail: Charlotte.niederlaender@uk-erlangen.de [Interdisciplinary Centre for Health Technology Assessment and Public Health, University of Erlangen-Nuremberg, National BMBF-Cluster of Excellence, “Medical Technologies - Medical Valley EMN”, Schwabachanlage 6, 91054 Erlangen (Germany); Kolominsky-Rabas, Peter, E-mail: Peter.kolominsky@uk-erlangen.de [Interdisciplinary Centre for Health Technology Assessment and Public Health, University of Erlangen-Nuremberg, National BMBF-Cluster of Excellence, “Medical Technologies - Medical Valley EMN”, Schwabachanlage 6, 91054 Erlangen (Germany)

    2013-11-01

    Objectives: The majority of recent cost-effectiveness reviews concluded that computerised tomographic colonography (CTC) is not a cost-effective colorectal cancer (CRC) screening strategy yet. The objective of this review is to examine cost-effectiveness of CTC versus optical colonoscopy (COL) for CRC screening and identify the main drivers influencing cost-effectiveness due to the emergence of new research. Methods: A systematic review was conducted for cost-effectiveness studies comparing CTC and COL as a screening tool and providing outcomes in life-years saved, published between January 2006 and November 2012. Results: Nine studies were included in the review. There was considerable heterogeneity in modelling complexity and methodology. Different model assumptions and inputs had large effects on resulting cost-effectiveness of CTC and COL. CTC was found to be dominant or cost-effective in three studies, assuming the most favourable scenario. COL was found to be not cost effective in one study. Conclusions: CTC has the potential to be a cost-effective CRC screening strategy when compared to COL. The most important assumptions that influenced the cost-effectiveness of CTC and COL were related to CTC threshold-based reporting of polyps, CTC cost, CTC sensitivity for large polyps, natural history of adenoma transition to cancer, AAA parameters and importantly, adherence. There is a strong need for a differential consideration of patient adherence and compliance to CTC and COL. Recent research shows that laxative-free CTC screening has the potential to become a good alternative screening method for CRC as it can improve patient uptake of screening.

  8. An international review of the main cost-effectiveness drivers of virtual colonography versus conventional colonoscopy for colorectal cancer screening: Is the tide changing due to adherence?

    International Nuclear Information System (INIS)

    Kriza, Christine; Emmert, Martin; Wahlster, Philip; Niederländer, Charlotte; Kolominsky-Rabas, Peter

    2013-01-01

    Objectives: The majority of recent cost-effectiveness reviews concluded that computerised tomographic colonography (CTC) is not a cost-effective colorectal cancer (CRC) screening strategy yet. The objective of this review is to examine cost-effectiveness of CTC versus optical colonoscopy (COL) for CRC screening and identify the main drivers influencing cost-effectiveness due to the emergence of new research. Methods: A systematic review was conducted for cost-effectiveness studies comparing CTC and COL as a screening tool and providing outcomes in life-years saved, published between January 2006 and November 2012. Results: Nine studies were included in the review. There was considerable heterogeneity in modelling complexity and methodology. Different model assumptions and inputs had large effects on resulting cost-effectiveness of CTC and COL. CTC was found to be dominant or cost-effective in three studies, assuming the most favourable scenario. COL was found to be not cost effective in one study. Conclusions: CTC has the potential to be a cost-effective CRC screening strategy when compared to COL. The most important assumptions that influenced the cost-effectiveness of CTC and COL were related to CTC threshold-based reporting of polyps, CTC cost, CTC sensitivity for large polyps, natural history of adenoma transition to cancer, AAA parameters and importantly, adherence. There is a strong need for a differential consideration of patient adherence and compliance to CTC and COL. Recent research shows that laxative-free CTC screening has the potential to become a good alternative screening method for CRC as it can improve patient uptake of screening

  9. Digital radiography versus conventional radiography during excretory urography: our experience

    International Nuclear Information System (INIS)

    Cervi, P.M.; Bighi, S.; Merlo, L.; Lupi, L.; Vita, G.

    1990-01-01

    The authors describe a computed radiographic system employed to generate and archive digital images in intravenous urography. For each exposure the system produces two digital images: the first (left image) simulates a conventional screen-film radiograph, the second (right image); enhances some spatial frequencies and emphasizes the margins of the structures. These images can be modified in their chief parameters and then printed by a laser-printer and archived on optical disks. Four experienced radiologists evaluated digital images with regard to some chief diagnostic parameters and, in 50 patients, they compared digital images with conventional screen-film radiographs and submitted the results to statistical analysis. For some of the chosen parameters, particularly for the evaluation of renal margins before and after contrast medium injection, digital images gave statistically better results than conventional films, while, no statistically significant different was observed for the other parameters. From the results of this preliminary study digital radiography was found to be useful in intravenous urography by reducing the patient's exposition dose, by always obtaining images of good quality, and by enhancing some particular features of the standard image; on the other hand there were many unsolved problems regarding the communicating and archiving system (PACS), because of the slowness of the image transfer procedure, difficulties in data transmission and complexity of referential procedures

  10. Determination of Lead(II), Cadmium(II) and Copper(II) in Waste-Water and Soil Extracts on Mercury Film Screen-Printed Carbon Electrodes Sensor

    International Nuclear Information System (INIS)

    Mohd Fairulnizal Md Noh; Tothill, I.E.

    2011-01-01

    A sensor incorporating a three electrodes configuration have been fabricated using low cost screen-printing technology. These electrodes couples with Square Wave Stripping Voltammetry (SWSV) has provided a convenient screening tool for on-site detection of trace levels of Pb(II), Cd(II) and Cu(II). Modification of the graphite carbon surface based on in situ deposition of mercury film has been carried out. By appropriate choice of supporting medium and optimized parameters setting such as amount of mercury used the deposition potential, deposition time, frequency and scan rate, well resolved and reproducible response for Pb(II), Cd(II) and Cu(II) were obtained. The performance characteristics of the developed mercury film screen printed carbon electrode (MFSPCE) for 120 s deposition time showed that the linear range for Cd(II), Pb(II) and Cu(II) were 10 to 200 μg L -1 . The detection limit recorded for Cd(II), Pb(II) and Cu(II) were 2, 1 and 5 μg L -1 with relative standard deviation (RSD) of 6.5 %, 6.9 % and 7.5 %, respectively. Successful applications of the sensing device to waste-water and extracted soil samples were demonstrated. (author)

  11. Digital radiography of the skeleton using a large-area detector based on amorphous silicon technology: Image quality and potential for dose reduction in comparison with screen-film radiography

    International Nuclear Information System (INIS)

    Volk, M.; Strotzer, M.; Holzkneckt, N.; Manke, C.; Lenhart, M.; Gmeinwieser, J.; Link, J.; Reiser, M.; Feuerback, S.

    2000-01-01

    AIM: The purpose of this study was to evaluate a large-area, flat-panel X-ray detector (FD), based on caesium-iodide (CsI) and amorphous silicon (a-Si) with respect to skeletal radiography. Conventional images were compared with digital radiographs using identical and reduced radiation doses. MATERIALS AND METHODS: Thirty consecutive patients were studied prospectively using conventional screen-film radiography (SFR; detector dose 2.5 μGy). Digital images were taken from the same patients with detector doses of 2.5, 1.25 and 0.625 μGy, respectively. The active-matrix detector had a panel size of 43 x 43 cm, a matrix of 3 x 3K, and a pixel size of 143 μm. All hard copies were presented in a random order to eight independent observers, who rated image quality according to subjective quality criteria. Results were assessed for significance using the Student's t -test (confidence level 95%). RESULTS: A statistically significant preference for digital over conventional images was revealed for all quality criteria, except for over-exposure (detector dose 2.5 μGy). Digital images with a 50% dose showed a small, statistically not significant, inferiority compared with SFR. The FD-technique was significantly inferior to SFR at 75% dose reduction regarding bone cortex and trabecula, contrast and overall impression. No statistically significant differences were found with regard to over- and under-exposure and soft tissue presentation. CONCLUSION: Amorphous silicon-based digital radiography yields good image quality. The potential for dose reduction depends on the clinical query. Volk, M. (2000)

  12. Diagnoses accuracy in the detection of abnormalities in the thorax x-ray: Teleradiology vs. conventional radiology

    International Nuclear Information System (INIS)

    Moron, Fanny Emilia; Melendez, Patricia; Martinez, Carlos Eli

    1998-01-01

    Background: introduction of teleradiology in Colombia is very recent and its operative characteristics and reliability are unknown. Objective: to evaluate intra and interobserver concordance in the interpretation of digitized chest x-ray films and to compare diagnostic Accuracy of teleradiology and film screen interpretation. Design: cross-sectional study for evaluation or concordance and operative characteristics of a diagnostic test. Patients and methods: convenience sample of 40 chest films. Independent lecture of digitized images for each radiologist to evaluate interobserver concordance: second lecture of digitized images for evaluation of intraobserver concordance. Generation of a gold standard diagnosis with a consensus interpretation of film screens, comparison of operative characteristics of teleradiology and conventional interpretation, using as a reference the gold standard (consensus lectures) and comparison of diagnostic precision using receiver operating characteristics curves (ROC curves). Results: agreements and concordance were significant higher than expected in both evaluations (inter and intraobserver). Sensitivity of teleradiology was similar to sensitivity of film screen interpretation and areas under ROC curves were not statistically different. Conclusions: concordance in the interpretation of chest radiological studies are significant in a teleradiology system and diagnostic utility of teleradiology is the same as conventional film screen interpretation. Accuracy and reliability of teleradiology are optimal

  13. Comparison between xCELLigence biosensor technology and conventional cell culture system for real-time monitoring human tenocytes proliferation and drugs cytotoxicity screening.

    Science.gov (United States)

    Chiu, Chih-Hao; Lei, Kin Fong; Yeh, Wen-Ling; Chen, Poyu; Chan, Yi-Sheng; Hsu, Kuo-Yao; Chen, Alvin Chao-Yu

    2017-10-16

    Local injections of anesthetics, NSAIDs, and corticosteroids for tendinopathies are empirically used. They are believed to have some cytotoxicity toward tenocytes. The maximal efficacy dosages of local injections should be determined. A commercial 2D microfluidic xCELLigence system had been developed to detect real-time cellular proliferation and their responses to different stimuli and had been used in several biomedical applications. The purpose of this study is to determine if human tenocytes can successfully proliferate inside xCELLigence system and the result has high correlation with conventional cell culture methods in the same condition. First passage of human tenocytes was seeded in xCELLigence and conventional 24-well plates. Ketorolac tromethamine, bupivacaine, methylprednisolone, and betamethasone with different concentrations (100, 50, and 10% diluted of clinical usage) were exposed in both systems. Gene expression of type I collagen, type III collagen, tenascin-C, decorin, and scleraxis were compared between two systems. Human tenocytes could proliferate both in xCELLigence and conventional cell culture systems. Cytotoxicity of each drug revealed dose-dependency when exposed to tenocytes in both systems. Significance was found between groups. All the four drugs had comparable cytotoxicity in their 100% concentration. When 50% concentration was used, betamethasone had a relatively decreased cytotoxicity among them in xCELLigence but not in conventional culture. When 10% concentration was used, betamethasone had the least cytotoxicity. Strong and positive correlation was found between cell index of xCELLigence and result of WST-1 assay (Pearson's correlation [r] = 0.914). Positive correlation of gene expression between tenocytes in xCELLigence and conventional culture was also observed. Type I collagen: [r] = 0.823; type III collagen: [r] = 0.899; tenascin-C: [r] = 0.917; decorin: [r] = 0.874; and scleraxis: [r] = 0.965. Human

  14. Discussion of ALTERNATIVE systems for industrial radiography using X-ray films

    International Nuclear Information System (INIS)

    Vaessen B.; Perdieus, P.; Proegler, H.

    1995-01-01

    Industrial radiography using X-ray films is an established method of NDE. In the last few years, ''novel developments'' have been put on the market as ''alternatives'' to conventional radiography, as e.g. fluorescent screen/film systems, cost-saving films, wide-latitude films, and storage phosphor films. AGFA as a market leader in the sector of X-ray films for industrial radiography has been testing these alternatives, taking into account image quality, sensitivity, handling in terms of portability, reliability, and the essential functions for NDE: (1) Detection of X-radiation; (2) conversion to optical image; (3) evaluation and validation; (4) documentation and archivation. The advantages and drawbacks, the information transfer capabilities, and the performance from the applications point of view are discussed primarily for fluorescent screen/film systems and storage phophor systems. (orig./MM) [de

  15. Wiener spectral effects of spatial correlation between the sites of characteristic x-ray emission and reabsorption in radiographic screen-film systems

    Energy Technology Data Exchange (ETDEWEB)

    Metz, C E; Vyborny, C J [Chicago Univ., IL (USA). Dept. of Radiology

    1983-05-01

    When characteristic x-rays are generated and reabsorbed in the phosphor of a radiographic screen-film system, the positions at which light is emitted from the initial and secondary interactions are correlated. A simple statistical model is developed to account for the effect of this correlation on the Wiener spectrum of quantum mottle. Unlike previous models, which ignore spatial correlation, the new model predicts that not only noise magnitude but also noise texture is changed as the incident x-ray energy exceeds the phosphor K-edge.

  16. Iridium Oxide-reduced Graphene Oxide Nanohybrid Thin Film Modified Screen-printed Electrodes as Disposable Electrochemical Paper Microfluidic pH Sensors.

    Science.gov (United States)

    Yang, Jiang; Kwak, Tae-Joon; Zhang, Xiaodong; McClain, Robert; Chang, Woo-Jin; Gunasekaran, Sundaram

    2016-11-22

    A facile, controllable, inexpensive and green electrochemical synthesis of IrO2-graphene nanohybrid thin films is developed to fabricate an easy-to-use integrated paper microfluidic electrochemical pH sensor for resource-limited settings. Taking advantages from both pH meters and strips, the pH sensing platform is composed of hydrophobic barrier-patterned paper micropad (µPAD) using polydimethylsiloxane (PDMS), screen-printed electrode (SPE) modified with IrO2-graphene films and molded acrylonitrile butadiene styrene (ABS) plastic holder. Repetitive cathodic potential cycling was employed for graphene oxide (GO) reduction which can completely remove electrochemically unstable oxygenated groups and generate a 2D defect-free homogeneous graphene thin film with excellent stability and electronic properties. A uniform and smooth IrO2 film in nanoscale grain size is anodically electrodeposited onto the graphene film, without any observable cracks. The resulting IrO2-RGO electrode showed slightly super-Nernstian responses from pH 2-12 in Britton-Robinson (B-R) buffers with good linearity, small hysteresis, low response time and reproducibility in different buffers, as well as low sensitivities to different interfering ionic species and dissolved oxygen. A simple portable digital pH meter is fabricated, whose signal is measured with a multimeter, using high input-impedance operational amplifier and consumer batteries. The pH values measured with the portable electrochemical paper-microfluidic pH sensors were consistent with those measured using a commercial laboratory pH meter with a glass electrode.

  17. Languages on the screen: is film comprehension related to the viewers' fluency level and to the language in the subtitles?

    Science.gov (United States)

    Lavaur, Jean-Marc; Bairstow, Dominique

    2011-12-01

    This research aimed at studying the role of subtitling in film comprehension. It focused on the languages in which the subtitles are written and on the participants' fluency levels in the languages presented in the film. In a preliminary part of the study, the most salient visual and dialogue elements of a short sequence of an English film were extracted by the means of a free recall task after showing two versions of the film (first a silent, then a dubbed-into-French version) to native French speakers. This visual and dialogue information was used in the setting of a questionnaire concerning the understanding of the film presented in the main part of the study, in which other French native speakers with beginner, intermediate, or advanced fluency levels in English were shown one of three versions of the film used in the preliminary part. Respectively, these versions had no subtitles or they included either English or French subtitles. The results indicate a global interaction between all three factors in this study: For the beginners, visual processing dropped from the version without subtitles to that with English subtitles, and even more so if French subtitles were provided, whereas the effect of film version on dialogue comprehension was the reverse. The advanced participants achieved higher comprehension for both types of information with the version without subtitles, and dialogue information processing was always better than visual information processing. The intermediate group similarly processed dialogues in a better way than visual information, but was not affected by film version. These results imply that, depending on the viewers' fluency levels, the language of subtitles can have different effects on movie information processing.

  18. Fracture healing: direct magnification versus conventional radiography

    International Nuclear Information System (INIS)

    Link, T.M.; Kessler, T.; Lange, T.; Overbeck, J.; Fiebich, M.; Peters, P.E.

    1994-01-01

    The aim of the study was to evaluate the potential of magnification radiography in diagnosing fracture healing and assessing its complications. Seventy-three patients with fractures or who had undergone osteotomy were radiographed with both conventional (non-magnified) and magnification (5-fold) techniques. Since 10 patients were radiographed twice and 1 three times, 83 radiographs using each technique were obtained. All radiographs were analysed and the findings correlated with the patients' follow-up studies. The microfocal X-ray unit used for magnification radiography had a focal spot size of 20-130 μm. As an imaging system, digital luminescence radiography was employed with magnification, while normal film-screen systems were used with conventional radiography. Magnification radiography proved superior to conventional radiography in 47% of cases: endosteal and periosteal callus formations were seen earlier and better in 26 cases, and osseous union could be evaluated with greater certainty in 33 cases. In 49% of cases magnification radiography was equal and in 4% inferior to conventional radiography. Additionally an ''inter-observer analysis'' was carried out. Anatomical and pathological structures were classified into one of four grades. Results were significantly (P < 0.01) better using magnification radiography. We conclude that the magnification technique is a good method for monitoring fracture healing in its early stages. (orig.)

  19. Single exposure simultaneous acquisition of digital and conventional radiographs utilizing unaltered dose

    International Nuclear Information System (INIS)

    Oestmann, J.W.; Greene, R.

    1988-01-01

    We describe the simultaneous acquisition of digital and conventional radiographs with a single standard radiographic exposure. A digitizable storage phosphor (ST Imaging Plate, Fuji) is sandwiched into a radiographic cassette (X-Omatic, Kodak) behind a conventional radiographic film-screen combination (Lanex medium screens, OC film, Kodak). The barium fluorohalide storage phosphor is digitized with a helium-neon laser scanner (TCR 201, Toshiba), and the conventional radiograph is processed in the standard fashion (M7B, Kodak). The storage phosphor is exposed by the 'wasted' radiation normally exiting the back of the film-screen combination (32% of the cassette entrance dose at 141 kVp). At a standard exposure (6.3 mAs), the conventional radiograph is of unaltered quality, and the digital image appears to have an adequate signal-to-noise ratio for chest studies despite the lower exposure dose. This technique produces twin images of identical spatial and temporal registration and avoids the added radiation exposure normally required to carry out comparative studies. (orig.)

  20. Establishing daily quality control (QC) in screen-film mammography using leeds tor (max) phantom at the breast imaging unit of USTH-Benavides Cancer Institute

    Science.gov (United States)

    Acaba, K. J. C.; Cinco, L. D.; Melchor, J. N.

    2016-03-01

    Daily QC tests performed on screen film mammography (SFM) equipment are essential to ensure that both SFM unit and film processor are working in a consistent manner. The Breast Imaging Unit of USTH-Benavides Cancer Institute has been conducting QC following the test protocols in the IAEA Human Health Series No.2 manual. However, the availability of Leeds breast phantom (CRP E13039) in the facility made the task easier. Instead of carrying out separate tests on AEC constancy and light sensitometry, only one exposure of the phantom is done to accomplish the two tests. It was observed that measurements made on mAs output and optical densities (ODs) using the Leeds TOR (MAX) phantom are comparable with that obtained from the usual conduct of tests, taking into account the attenuation characteristic of the phantom. Image quality parameters such as low contrast and high contrast details were also evaluated from the phantom image. The authors recognize the usefulness of the phantom in determining technical factors that will help improve detection of smallest pathological details on breast images. The phantom is also convenient for daily QC monitoring and economical since less number of films is expended.

  1. Anti-microbial surfaces: An approach for deposition of ZnO nanoparticles on PVA-Gelatin composite film by screen printing technique

    Energy Technology Data Exchange (ETDEWEB)

    Meshram, J.V.; Koli, V.B.; Phadatare, M.R.; Pawar, S.H., E-mail: shpawar1946@gmail.com

    2017-04-01

    Initially micro-organisms get exposed to the surfaces, this demands development of anti-microbial surfaces to inhibit their proliferation. Therefore, herein, we attempt screen printing technique for development of PVA-GE/ZnO nanocomposite (PG/ZnO) films. The synthesis of PG/ZnO nanocomposite includes two steps as: (i) Coating of Zinc Oxide nanoparticles (ZnO NPs) by poly ethylene glycol in order to be compatible with organic counterparts. (ii) Deposition of coated nanoparticles on the PG film surface. The results suggest the enhancement in anti-microbial activity of PG/ZnO nanocomposite over pure ZnO NPs against both Gram positive Bacillus subtilis and Gram negative Escherichia coli from zone of inhibition. The uniformity in deposition is further confirmed by scanning electron microscopy (SEM) images. The phase identification of ZnO NPs and formation of PG/ZnO nanocomposite has been confirmed by X-ray diffraction (XRD) analysis and UV–vis spectroscopy (UV–vis). The Attenuated total reflection Spectroscopy (ATR) analysis indicates the ester bond between PVA and gelatin molecules. The thermal stability of nanocomposite is studied by thermogravimetric analysis (TGA) revealing increase in crystallinity due to ZnO NPs which could be utilized to inhibit the growth of micro-organisms. The tensile strength is found to be higher and percent elongation is double of PG/ZnO nanocomposite than PG composite film. - Highlights: • Synthesis of PG/ZnO nanocomposite by screen printing technique • Antimicrobial activity is due presence of ZnO nanoparticles on PG composite. • Improved tensile strength due to ZnO nanoparticles.

  2. A new system for port films.

    Science.gov (United States)

    Sephton, R; Green, M; Fitzpatrick, C

    1989-01-01

    A novel system for port films is described which incorporates a high-quality fluorescent screen lying behind a flat, heavy-metal screen or filter and the film pressed between them is not an X ray type but a single-emulsion, very high contrast graphics or line-type film. In experimental comparisons using 4 MV, 6 MV, and 25 MV photon beams, the new Peter MacCallum Cancer Institute (PMCI) system produced clearer images, about X2 higher in contrast yet lower in relative noise levels, than did the conventional commercially-available systems which use x-ray film between heavy-metal screens. Direct clinical comparisons, chiefly using 6 MV accelerators, confirmed that anatomical details were correspondingly better visualized and in general, the PMCI port film could be matched against the simulator radiograph with greater confidence. Routine use for greater than 2 yr in this Institute (4000 new patients per yr, 20 cassettes made for use with four 6 MV accelerators) has shown the PMCI system to be an economical and practical device, giving reproducibly high quality images in all the common port film applications.

  3. A study of a reduction of patient's radiation exposure by using the new ortho screen film system. 3. A study of Kodak InSight EF/RA imaging system

    International Nuclear Information System (INIS)

    Yagi, Hiroshi; Imura, Hiroyoshi; Amano, Masafumi; Kuroda, Tokue; Nishitani, Hiromu.

    1995-01-01

    The developing temperature dependency of Kodak InSight EF/RA Image System (IEF system) was evaluated by measuring characteristic curve, resolution properties and noise RMS. Furthermore, the possibility of the reduction of the patient's exposure without decrease in image quality was evaluated. The physical imaging properties of screen/film systems were affected by the developing temperature. Except the gross fog, other imaging properties of IEF system on developing temperature was small. Especially it was confirmed that the developing temperature dependency of granularity of IEF system was less than those of the other new ortho screen film systems (Konica ES-C medical x-ray film of EX system and Fuji UR-1 medical x-ray film of AD system). Therefore, there is the possibility of the reduction of the patient's exposure by using the higher developing temperature than the traditional situation after due consideration of increasing the gross fog. (author)

  4. Dumping convention

    International Nuclear Information System (INIS)

    Roche, P.

    1992-01-01

    Sea dumping of radioactive waste has, since 1983, been precluded under a moratorium established by the London Dumping Convention. Pressure from the nuclear industry to allow ocean dumping of nuclear waste is reported in this article. (author)

  5. Combinatorial screening of halide perovskite thin films and solar cells by mask-defined IR laser molecular beam epitaxy

    OpenAIRE

    Kawashima, Kazuhiro; Okamoto, Yuji; Annayev, Orazmuhammet; Toyokura, Nobuo; Takahashi, Ryota; Lippmaa, Mikk; Itaka, Kenji; Suzuki, Yoshikazu; Matsuki, Nobuyuki; Koinuma, Hideomi

    2017-01-01

    Abstract As an extension of combinatorial molecular layer epitaxy via ablation of perovskite oxides by a pulsed excimer laser, we have developed a laser molecular beam epitaxy (MBE) system for parallel integration of nano-scaled thin films of organic?inorganic hybrid materials. A pulsed infrared (IR) semiconductor laser was adopted for thermal evaporation of organic halide (A-site: CH3NH3I) and inorganic halide (B-site: PbI2) powder targets to deposit repeated A/B bilayer films where the thic...

  6. A sensitive electrochemical immunosensor based on poly(2-aminobenzylamine) film modified screen-printed carbon electrode for label-free detection of human immunoglobulin G.

    Science.gov (United States)

    Putnin, Thitirat; Jumpathong, Watthanachai; Laocharoensuk, Rawiwan; Jakmunee, Jaroon; Ounnunkad, Kontad

    2018-08-01

    This work focuses on fabricating poly(2-aminobenzylamine)-modified screen-printed carbon electrode as an electrochemical immunosensor for the label-free detection of human immunoglobulin G. To selectively detect immunoglobulin G, the anti-immunoglobulin G antibody with high affinity to immunoglobulin G was covalently linked with the amine group of poly(2-aminobenzylamine) film-deposited screen-printed carbon electrode. The selectivity for immunoglobulin G was subsequently assured by being challenged with redox-active interferences and adventitious adsorption did not significantly interfere the analyte signal. To obviate the use of costly secondary antibody, the [Fe(CN) 6 ] 4-/3- redox probe was instead applied to measure the number of human immunoglobulin G through the immunocomplex formation that is quantitatively related to the level of the differential pulse voltammetric current. The resulting immunosensor exhibited good sensitivity with the detection limit of 0.15 ng mL -1 , limit of quantitation of 0.50 ng mL -1 and the linear range from 1.0 to 50 ng mL -1 . Given those striking analytical performances and the affordability arising from using cheap screen-printed carbon electrode with label-free detection, the immunosensor serves as a promising model for the next-step development of a diagnostic tool.

  7. Fully Screen-Printed, Large-Area, and Flexible Active-Matrix Electrochromic Displays Using Carbon Nanotube Thin-Film Transistors.

    Science.gov (United States)

    Cao, Xuan; Lau, Christian; Liu, Yihang; Wu, Fanqi; Gui, Hui; Liu, Qingzhou; Ma, Yuqiang; Wan, Haochuan; Amer, Moh R; Zhou, Chongwu

    2016-11-22

    Semiconducting single-wall carbon nanotubes are ideal semiconductors for printed electronics due to their advantageous electrical and mechanical properties, intrinsic printability in solution, and desirable stability in air. However, fully printed, large-area, high-performance, and flexible carbon nanotube active-matrix backplanes are still difficult to realize for future displays and sensing applications. Here, we report fully screen-printed active-matrix electrochromic displays employing carbon nanotube thin-film transistors. Our fully printed backplane shows high electrical performance with mobility of 3.92 ± 1.08 cm 2 V -1 s -1 , on-off current ratio I on /I off ∼ 10 4 , and good uniformity. The printed backplane was then monolithically integrated with an array of printed electrochromic pixels, resulting in an entirely screen-printed active-matrix electrochromic display (AMECD) with good switching characteristics, facile manufacturing, and long-term stability. Overall, our fully screen-printed AMECD is promising for the mass production of large-area and low-cost flexible displays for applications such as disposable tags, medical electronics, and smart home appliances.

  8. Crossover And MTF Characteristics Of A Tabular-Grain X-Ray Film

    Science.gov (United States)

    Huff, K. E.; Wagner, P. W.

    1984-08-01

    An orthochromatic x-ray film made with tabular silver halide grains has a significantly higher MTF when exposed with green-emitting intensifying screens than do conventional films with similar sensitometric properties. The primary reason for the improved MTF is a decrease in the amount of crossover exposure, i.e., exposure by light that has crossed the support one or more times. Two well-established sensitometric procedures for measuring crossover have been compared. One produces results accurate enough for calculations of MTF relationships. Calculated MTF relationships for tabulargrain and conventional films are compared with measured values.

  9. Let's Talk About Water: Using Film Screenings to Engage Students and the Public in Water Science and Policy

    Science.gov (United States)

    Saleem Arrigo, J. A.; Berry, K.; Hooper, R. P.; Lilienfeld, L.

    2013-12-01

    "Let's Talk about Water" is a film symposium designed to bring together experts and the public to talk about the complex water issues facing society. The format of the event is quite simple: a panel of experts and the audience view a water documentary (such as "FLOW", "Liquid Assets", or "Gasland") together and there is an extended moderated discussion period following the film between the panel and the audience. Over the course of several events, we have developed best practices that make this simple format very effective. A film creates a context of subject and language for the discussion--it gets the audience and the panel on the same page. The moderators must actively manage the discussion, both challenging the panelists with follow up questions, asking questions to simplify the language the expert is using, and passing a question among panelists to bring out different points of view. The panelists are provided with the film in advance to view and, most importantly, meet the day before the event to discuss the film. This makes for a much more convivial discussion at the event. We have found that these discussions can easily be sustained for 90 to 120 minutes with active audience participation. We have found key element of the event is local relevance. Films should be carefully chosen to resonate with the audience, and the local host is critical in defining the audience, goals and identified panel members. Having local experts from universities and representatives from local water authorities and environmental groups bring a sense of community and a confidence in the audience that the panel members have local knowledge that is important for sustaining discussion. The discussion begins with points raised by the movie (are these issues real? Do they apply here? What are the scientific, engineering, and policy solutions to these problems?) and then segues into a discussion about career opportunities in the water sector, volunteer opportunities in the community or

  10. Development of conventional and single-chamber planar solid oxide fuel cells by screen-printing; Developpement de piles a combustible de type SOFC, conventionnelles et mono-chambres, en technologie planaire par serigraphie

    Energy Technology Data Exchange (ETDEWEB)

    Rotureau, D.

    2005-06-15

    This work is the first of a new research theme of the laboratory in the field of solid oxide planar fuel cells. With his high experience in the sensor field, the objectives were to realize prototypes using a 'low cost' technology like screen-printing, using classical materials in the field of fuel cells, rather than researching new materials having optimum properties which may be damaged during the realisation of the complete fuel cell. These materials are yttria stabilised zirconia (YSZ) for electrolyte, strontium doped lanthanum manganite (LSM) for cathode and a nickel oxide-YSZ cermet (NiO-YSZ) for anode. The first part of the study consists in structural and electrical characterizations of chosen materials, both on dense pellets and on screen-printed layers of YSZ, LSM or NiO-YSZ. These characterizations showed a good adequation of our materials for a fuel cell application. The second part consists in testing realised prototypes on electrolyte support and on anode support with screen-printed electrodes and electrolyte. The weak obtained performances are mainly due to the low functional temperature (800 C), the thickness of the electrolyte support (about 1 mm) and the porosity of the YSZ screen-printed layers. Finally, we tested in the same time an original device in which both electrodes are exposed to a fuel and air mixture. This promising device inspired from the research on potentiometric sensors developed in the team by N. Guillet (2001), avoids the tightness problem encountered with two gaseous chambers. Moreover, the performances obtained are just twice below than those obtained with a conventional fuel cell with two gaseous chambers. (author)

  11. Follow-up and Final Results of the Oslo I Study Comparing Screen-Film Mammography and Full-field Digital Mammography with Soft-Copy Reading

    International Nuclear Information System (INIS)

    Skaane, P.; Skjennald, A.; Young, K.

    2005-01-01

    Purpose: To compare cancer detection rates of screen-film (SFM) and full-field digital mammography (FFDM) with soft-copy reading in a screening program including the initial positive scores for interval cancers and cancers in the subsequent screening round, and to analyze the false-negative FFDM interpretations. Material and Methods: Using a paired study design, 3683 women underwent SFM and FFDM in a population-based screening program. Two standard views of each breast were acquired. The images were interpreted without previous films for comparison. Independent double reading using a 5-point rating scale for probability of cancer was used for each modality. An examination was defined as positive if at least one of the two independent readers scored 2 or higher on the 5-point rating scale. SFM-positive cases were discussed in a SFM consensus meeting and FFDM-positive cases in a separate FFDM consensus meeting before recall. The study population was followed for more than 2 years so that interval cancers and screen-detected cancers in the subsequent screening round could be included. Cancer detection rates were compared using the McNemar test for paired proportions. The kappa statistic and Wilcoxon signed-rank test for matched pairs were used for comparing rating scores. The reading time was recorded for all FFDM interpretations. Results: A total of 31 cancers (detection rate 0.84%) were diagnosed initially, of which SFM detected 28 and FFDM 23 (McNemar test P 0.23, discordant pair 8 and 3). Two cancers with a positive score at initial SFM reading and three with a positive score at initial FFDM reading were dismissed at SFM and FFDM consensus meetings, respectively. The difference in cancer detection after recall (discordant pair 11 and 5) was not significant (McNemar test, P = 0.21). Of the 10 interval cancers and 16 screen-detected cancers in the subsequent round, 3 had true-positive SFM scores while 4 had true-positive FFDM scores in the initial reading session. A

  12. Follow-up and Final Results of the Oslo I Study Comparing Screen-Film Mammography and Full-field Digital Mammography with Soft-Copy Reading

    Energy Technology Data Exchange (ETDEWEB)

    Skaane, P.; Skjennald, A.; Young, K. [Ullevaal Univ. Hospital, Oslo (Norway). Dept. of Radiology] [and others

    2005-11-01

    Purpose: To compare cancer detection rates of screen-film (SFM) and full-field digital mammography (FFDM) with soft-copy reading in a screening program including the initial positive scores for interval cancers and cancers in the subsequent screening round, and to analyze the false-negative FFDM interpretations. Material and Methods: Using a paired study design, 3683 women underwent SFM and FFDM in a population-based screening program. Two standard views of each breast were acquired. The images were interpreted without previous films for comparison. Independent double reading using a 5-point rating scale for probability of cancer was used for each modality. An examination was defined as positive if at least one of the two independent readers scored 2 or higher on the 5-point rating scale. SFM-positive cases were discussed in a SFM consensus meeting and FFDM-positive cases in a separate FFDM consensus meeting before recall. The study population was followed for more than 2 years so that interval cancers and screen-detected cancers in the subsequent screening round could be included. Cancer detection rates were compared using the McNemar test for paired proportions. The kappa statistic and Wilcoxon signed-rank test for matched pairs were used for comparing rating scores. The reading time was recorded for all FFDM interpretations. Results: A total of 31 cancers (detection rate 0.84%) were diagnosed initially, of which SFM detected 28 and FFDM 23 (McNemar test P 0.23, discordant pair 8 and 3). Two cancers with a positive score at initial SFM reading and three with a positive score at initial FFDM reading were dismissed at SFM and FFDM consensus meetings, respectively. The difference in cancer detection after recall (discordant pair 11 and 5) was not significant (McNemar test, P = 0.21). Of the 10 interval cancers and 16 screen-detected cancers in the subsequent round, 3 had true-positive SFM scores while 4 had true-positive FFDM scores in the initial reading session. A

  13. Between Stage and Screen

    NARCIS (Netherlands)

    Tornqvist, Egil

    1996-01-01

    Ingmar Bergman is worldwide known as a film and stage director. Yet no-one has attempted to compare his stage and screen activities. In Between stage and screen Egil Tornqvist examines formal and thematical correspondences and differences between a number of Bergman's stage, screen, and radio

  14. Objective image quality parameters of relevance in practice, measured for film-screen combinations - a contribution to quality assurance activities

    International Nuclear Information System (INIS)

    Angerstein, W.; Wolf, M.

    1986-01-01

    Objective measurement of the physico-technical parameters determining the image quality is the fastest and most accurate method of quality testing of the systems. The parameters in case of X-ray intensifying screens are imaging quality, servicable life, and mechanical properties. (orig./DG) [de

  15. The influence of film-screen color sensitivity and type of measurement device on kVp measurements.

    Science.gov (United States)

    Lam, R W; Price, S C

    1989-01-01

    Three methods for evaluating radiographic kVp were studied: the Wisconsin Test Cassette, the Noninvasive Evaluator of Radiation Outputs (NERO), and the Dynalyzer. The Dynalyzer kVp readings were the highest and were followed by NERO and cassette readings in descending order. By film type, the cassette readings ranged from Kodak OG (green sensitive), TMG (green sensitive), XK (blue sensitive), and XRP (blue sensitive) in descending order. The results show that there is significant variation between the methods.

  16. Sheet resistance, transmittance, and chromatic property of CNTs coated with PEDOT:PSS films for transparent electrodes of touch screen panels

    International Nuclear Information System (INIS)

    Kim, Bu-Jong; Han, Sang-Hoon; Park, Jin-Seok

    2014-01-01

    This study demonstrates hybrid-type transparent electrodes based on carbon nanotubes (CNTs) that possess characteristics desirable for touch screen panels. This has been accomplished by depositing CNTs via spray-coating and then depositing thin conductive polymer (such as PEDOT:PSS) films on the CNTs via spin-coating. For all of the samples such as CNTs, PEDOT:PSS, and hybrid (i.e., PEDOT:PSS-coated CNTs), their surface morphologies, sheet resistances, visible transmittances, and chromatic properties are characterized as functions of their preparation conditions. In the PEDOT:PSS-coated CNTs, the PEDOT:PSS particles fill up the voids between tubes in CNTs, forming a conduction bridge for electron transfer and eventually decreasing the sheet resistance of the hybrid electrode. Also, the hybrid electrode reveals a superior color property compared with that of CNTs or the PEDOT:PSS single electrode due to the complementary color relation between CNTs and PEDOT:PSS. Experimental results show that the fabricated hybrid-type electrodes can simultaneously satisfy the requirements necessary for transparent electrodes of touch screen panels such as the sheet resistance requiring to be lower than 100 Ω/sq, visible transmittance higher than 80%, and yellowness approaching to zero. - Highlights: • Hybrid-type (PEDOT:PSS-coated CNTs) electrodes for touch panels are fabricated. • PEDOT:PSS films are coated via spin-coating on spray-deposited CNTs. • Hybrid electrodes are fabricated by varying the thickness of CNTs and PEDOT:PSS. • The resistance, transmittance, and color properties have been analyzed. • Hybrid electrodes satisfy electrical and optical properties for touch panels

  17. Sheet resistance, transmittance, and chromatic property of CNTs coated with PEDOT:PSS films for transparent electrodes of touch screen panels

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bu-Jong; Han, Sang-Hoon; Park, Jin-Seok

    2014-12-01

    This study demonstrates hybrid-type transparent electrodes based on carbon nanotubes (CNTs) that possess characteristics desirable for touch screen panels. This has been accomplished by depositing CNTs via spray-coating and then depositing thin conductive polymer (such as PEDOT:PSS) films on the CNTs via spin-coating. For all of the samples such as CNTs, PEDOT:PSS, and hybrid (i.e., PEDOT:PSS-coated CNTs), their surface morphologies, sheet resistances, visible transmittances, and chromatic properties are characterized as functions of their preparation conditions. In the PEDOT:PSS-coated CNTs, the PEDOT:PSS particles fill up the voids between tubes in CNTs, forming a conduction bridge for electron transfer and eventually decreasing the sheet resistance of the hybrid electrode. Also, the hybrid electrode reveals a superior color property compared with that of CNTs or the PEDOT:PSS single electrode due to the complementary color relation between CNTs and PEDOT:PSS. Experimental results show that the fabricated hybrid-type electrodes can simultaneously satisfy the requirements necessary for transparent electrodes of touch screen panels such as the sheet resistance requiring to be lower than 100 Ω/sq, visible transmittance higher than 80%, and yellowness approaching to zero. - Highlights: • Hybrid-type (PEDOT:PSS-coated CNTs) electrodes for touch panels are fabricated. • PEDOT:PSS films are coated via spin-coating on spray-deposited CNTs. • Hybrid electrodes are fabricated by varying the thickness of CNTs and PEDOT:PSS. • The resistance, transmittance, and color properties have been analyzed. • Hybrid electrodes satisfy electrical and optical properties for touch panels.

  18. A study of reduction of patient's radiation exposure by using the new ortho screen film systems (4). A study of the possibility of higher developing temperature by observation of chest phantom radiographs

    International Nuclear Information System (INIS)

    Yagi, Hirofumi; Fukui, Toshihito; Yasutomo, Motokatsu; Takashima, Koosuke; Kuroda, Tokue; Nishitani, Hiromu.

    1995-01-01

    Recently, some new ortho screen-film systems (Konica EX system, Fuji AD system and Kodak IEF system) are being developed. The granulalities of these systems have been greatly improved and gross fogs are lower than those of traditional ortho screen-film systems. Even if the radiographs with the new ortho screen-film are processed at higher temperature than with the old ortho system such as Lanex Medium/TMC-RA (Eastman Kodak), the deterioration in the image quality is negligible. Furthermore, the speed of the screen-film systems increases as the developing temperature rises. Therefore, there may be the potential to reduce patients' radiation exposure without greatly decreasing the image quality. At that time, the problem arises how to determine the appropriate developing temperature. The limit of developing temperature for the new ortho system was determined as the temperature for getting the same gross fog in old ortho-system. In this report, phantom radiographs were made at various developing temperatures and the comments about the higher limit of the developing temperature were solicited from medical doctors who evaluated them. Consequently, it has been confirmed there are sufficient image quality in the radiographs which were developed at the higher developing temperature than at the temperature used in many faculties now. (author)

  19. Films and dark room

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    After we know where the radiographic come from, then we must know about the film and also dark room. So, this chapter 5 discusses the two main components for radiography work that is film and dark room, places to process the film. Film are structured with three structured that are basic structured, emulsion and protection structured. So, this film can be classified either with their speed, screen and standard that used. The process to wash the film must be done in dark room otherwise the radiographer cannot get what are they inspected. The processing of film will be discussed briefly in next chapter.

  20. Pinning down high-performance Cu-chalcogenides as thin-film solar cell absorbers: A successive screening approach

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yubo; Zhang, Wenqing, E-mail: wqzhang@mail.sic.ac.cn, E-mail: pzhang3@buffalo.edu [Materials Genome Institute and Department of Physics, Shanghai University, Shanghai 200444 (China); State Key Laboratory of High Performance Ceramics and Superfine Microstructures, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050 (China); Wang, Youwei; Zhang, Jiawei; Xi, Lili [State Key Laboratory of High Performance Ceramics and Superfine Microstructures, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050 (China); Zhang, Peihong, E-mail: wqzhang@mail.sic.ac.cn, E-mail: pzhang3@buffalo.edu [Materials Genome Institute and Department of Physics, Shanghai University, Shanghai 200444 (China); Department of Physics, University at Buffalo, SUNY, Buffalo, New York 14260 (United States)

    2016-05-21

    Photovoltaic performances of Cu-chalcogenides solar cells are strongly correlated with the absorber fundamental properties such as optimal bandgap, desired band alignment with window material, and high photon absorption ability. According to these criteria, we carry out a successive screening for 90 Cu-chalcogenides using efficient theoretical approaches. Besides the well-recognized CuInSe{sub 2} and Cu{sub 2}ZnSnSe{sub 4} materials, several novel candidates are identified to have optimal bandgaps of around 1.0–1.5 eV, spike-like band alignments with CdS window layer, sharp photon absorption edges, and high absorption coefficients. These new systems have great potential to be superior absorbers for photovolatic applications if their carrrier transport and defect properties are properly optimized.

  1. Performance improvements of pouch-type flexible thin-film lithium-ion batteries by modifying sequential screen-printing process

    International Nuclear Information System (INIS)

    Kang, Kun-Young; Lee, Young-Gi; Shin, Dong Ok; Kim, Jin-Chul; Kim, Kwang Man

    2014-01-01

    A pouch-type flexible thin-film lithium-ion battery is fabricated by sequential screen-printing (wet) processes to produce consecutive layers of a current collector, positive and negative electrodes, and a gel polymer electrolyte. Optimum conditions of each process are determined by adjusting the paste or slurry compositions to achieve lower surface resistance of each layer (current collector and electrodes) and higher ionic conductivity of the gel polymer electrolyte. The fabricated flexible thin-film lithium-ion battery (5.5 × 5.5 cm 2 , 325 μm thick) shows superior electrochemical performance, including an energy density of 292.3 Wh L −1 based on electrode size (4.0 × 4.0 cm 2 ), an initial discharge capacity of 2.5 mAh cm −2 per electrode area, and capacity retention ratio of over 68% at the 50th cycle. To further improve the battery performance, the wet processes are modified by adopting hybrid (dry-wet) processes, which mainly consist of the formation of metallic current collector layers (Al and Cu) using a thermal evaporator and another optimized gel polymer electrolyte, to achieve an energy density of 332.8 Wh L −1 and capacity retention ratio of 84% at the 50th cycle. Cell flexibility is also confirmed by stable open circuit voltages after the system is subjected to several hundred iterations of bending, stretching, and even folding. There is the possibility that the suggested wet and dry-wet processes can be expanded to a high-speed mass-production roll-to-roll process

  2. Film quality in film mammography. Pt. 2

    International Nuclear Information System (INIS)

    Friedrich, M.; Weskamp, P.; Freie Univ. Berlin

    1976-01-01

    During consideration of three film mammographic systems, the concept of signal/noise ratio is developed as a quantitative measure of film quality. The ability to recognise detail related to detail size, film blackening and exposure geometry was studied for various systems, and the quality profiles are discussed. There is a considerable difference in quality between industrial films without screens and film-screen combinations; however, exposure geometry during mammography has a considerable effect which tends to reduce the difference. Consequently, detail sizes of 200 μ to 1,000 μ (including the majority of mammographic micro-calcifications) are shown about equally well. Contrast for the lo-dose system is somewhat less than for adequately exposed industrial film. Over-exposure with the lo-dose system, contrary to industrial film, rapidly leads to unsatisfactory results. On the other hand it is often not possible to obtain an adequate exposure when using industrial film. For these reasons it is often an advantage to examine large breasts and the dense breasts of young women with a film-screen combination which requires approximately one eighth of the dose necessary for industrial film. For small or easily compressable breasts best results are obtained, using an adequate exposure by employing industril film; radiation dose it then acceptable. (orig./ORU) [de

  3. An engineering development of fluoroscopic X-ray medical equipment based-on fluorescent screen

    International Nuclear Information System (INIS)

    Ferry Suyatno; I Putu Susila; Djoko Sukmono

    2011-01-01

    Fluoroscopic x-ray medical equipment uses fluorescent screen to capture structural image of organs. Unlike conventional x-ray equipment which uses film, in the fluoroscopic x-ray, the resulting image is visualized on the fluorescent screen and directly observed by physicians in the patients' rooms. In this study, we developed an image capture system that transforms the image on the fluorescent screen into digital data, which is then transferred to computer for visualization and further processing. By using this system, the observation of the resulting image can be done on a computer that is placed in the control room. The image can also be stored easily and at low cost compared to conventional film. The experiment shows that the system could be used to capture image of the object. However, its quality needs to be improved. In the future, the system will be modified and tested with different types of cameras to obtain better results. (author)

  4. Metallic oxide switches using thick film technology

    Science.gov (United States)

    Patel, D. N.; Williams, L., Jr.

    1974-01-01

    Metallic oxide thick film switches were processed on alumina substrates using thick film technology. Vanadium pentoxide in powder form was mixed with other oxides e.g., barium, strontium copper and glass frit, ground to a fine powder. Pastes and screen printable inks were made using commercial conductive vehicles and appropriate thinners. Some switching devices were processed by conventional screen printing and firing of the inks and commercial cermet conductor terminals on 96% alumina substrates while others were made by applying small beads or dots of the pastes between platinum wires. Static, and dynamic volt-ampere, and pulse tests indicate that the switching and self-oscillatory characteristics of these devices could make them useful in memory element, oscillator, and automatic control applications.

  5. Development of an imaging-planning program for screen/film and computed radiography mammography for breasts with short chest wall to nipple distance.

    Science.gov (United States)

    Dong, S L; Su, J L; Yeh, Y H; Chu, T C; Lin, Y C; Chuang, K S

    2011-04-01

    Imaging breasts with a short chest wall to nipple distance (CWND) using a traditional mammographic X-ray unit is a technical challenge for mammographers. The purpose of this study is the development of an imaging-planning program to assist in determination of imaging parameters of screen/film (SF) and computed radiography (CR) mammography for short CWND breasts. A traditional mammographic X-ray unit (Mammomat 3000, Siemens, Munich, Germany) was employed. The imaging-planning program was developed by combining the compressed breast thickness correction, the equivalent polymethylmethacrylate thickness assessment for breasts and the tube loading (mAs) measurement. Both phantom exposures and a total of 597 exposures were used for examining the imaging-planning program. Results of the phantom study show that the tube loading rapidly decreased with the CWND when the automatic exposure control (AEC) detector was not fully covered by the phantom. For patient exposures with the AEC fully covered by breast tissue, the average fractional tube loadings, defined as the ratio of the predicted mAs using the imaging-planning program and mAs of the mammogram, were 1.10 and 1.07 for SF and CR mammograms, respectively. The predicted mAs values were comparable to the mAs values, as determined by the AEC. By applying the imaging-planning program in clinical practice, the experiential dependence of the mammographer for determination of the imaging parameters for short CWND breasts is minimised.

  6. The change of radiation doses to the patient when switching from conventional technique to digital technique without films in barium enema and IVU examinations. Final report SSI research project P933

    CERN Document Server

    Sjöholm, B

    2003-01-01

    X-ray examinations of the colon (barium enema) and the kidneys (IVU) are combined with rather high radiation doses to the patients when using analogue technique with film-screen systems. It is therefore of great interest to see if the change from analogue to digital technique involves a reduction of doses. Barium enema and IVU examinations were monitored with DAP-meters before and after the X-ray department changed to digital techniques. For IVU also the change from storage phosphor plates to a Direct Digital detector is included. The study comprises between 53 and 87 patients for each modality of the two examinations. A considerable dose reduction was observed. In barium enema the overview images with large field sizes were omitted when using digital technique. On the other hand the number of spot images was increased from 6 to 22. The fluoroscopy time was increased from 4 minutes to 6 minutes. The DAP value was reduced from 54,3 Gy cm sup 2 to 21,9 Gy cm sup 2. For IVU a dose reduction from 44,5 Gy cm sup 2...

  7. Optimization of technique factors for a silicon diode array full-field digital mammography system and comparison to screen-film mammography with matched average glandular dose

    International Nuclear Information System (INIS)

    Berns, Eric A.; Hendrick, R. Edward; Cutter, Gary R.

    2003-01-01

    Contrast-detail experiments were performed to optimize technique factors for the detection of low-contrast lesions using a silicon diode array full-field digital mammography (FFDM) system under the conditions of a matched average glandular dose (AGD) for different techniques. Optimization was performed for compressed breast thickness from 2 to 8 cm. FFDM results were compared to screen-film mammography (SFM) at each breast thickness. Four contrast-detail (CD) images were acquired on a SFM unit with optimal techniques at 2, 4, 6, and 8 cm breast thicknesses. The AGD for each breast thickness was calculated based on half-value layer (HVL) and entrance exposure measurements on the SFM unit. A computer algorithm was developed and used to determine FFDM beam current (mAs) that matched AGD between FFDM and SFM at each thickness, while varying target, filter, and peak kilovoltage (kVp) across the full range available for the FFDM unit. CD images were then acquired on FFDM for kVp values from 23-35 for a molybdenum-molybdenum (Mo-Mo), 23-40 for a molybdenum-rhodium (Mo-Rh), and 25-49 for a rhodium-rhodium (Rh-Rh) target-filter under the constraint of matching the AGD from screen-film for each breast thickness (2, 4, 6, and 8 cm). CD images were scored independently for SFM and each FFDM technique by six readers. CD scores were analyzed to assess trends as a function of target-filter and kVp and were compared to SFM at each breast thickness. For 2 cm thick breasts, optimal FFDM CD scores occurred at the lowest possible kVp setting for each target-filter, with significant decreases in FFDM CD scores as kVp was increased under the constraint of matched AGD. For 2 cm breasts, optimal FFDM CD scores were not significantly different from SFM CD scores. For 4-8 cm breasts, optimum FFDM CD scores were superior to SFM CD scores. For 4 cm breasts, FFDM CD scores decreased as kVp increased for each target-filter combination. For 6 cm breasts, CD scores decreased slightly as k

  8. Comparison of digital selenium radiography with an analog screen-film system in the diagnostic process of pneumoconiosis according to ILO classification; Vergleich der digitalen Selenradiographie mit einem analogen Film-Folien-System in der Diagnostik von Staublungenerkrankungen anhand der ILO-Klassifikation

    Energy Technology Data Exchange (ETDEWEB)

    Zaehringer, M.; Winnekendonk, G.; Gossmann, A.; Krueger, K.; Krug, B. [Koeln Univ. (Germany). Inst. und Poliklinik fuer Radiologische Diagnostik; Piekarski, C.; Saupe, M. [Koeln Univ. (Germany). Inst. und Poliklinik fuer Arbeitsmedizin, Sozialmedizin und Sozialhygiene; Braun, W. [Koeln Univ. (DE). Inst. fuer Medizinische Statistik, Informatik und Epidemiologie (IMSIE)

    2001-10-01

    Purpose: The aim of the study was to determine the diagnostic value of digital selenium radiography in patients with pneumoconiosis. For this purpose chest X-rays by digital selenium radiography and analog screen-film system were compared according to the ILO classification of pneumoconiosis. Method: After approval of the study by the local ethic commission and the Federal German Office for Radiation Protection 50 patients were subjected to X-rays by digital selenium radiography (Thoravision; Philips Medical Systems, Hamburg, Germany) and analog screen-film system of the same day within the scope of an industrial medicine preventive checkup. Four investigators rated the chest X-rays according to the ILO classification of pneumoconiosis. Results: The findings demonstrated by chest X-rays according to ILO classification were rated similar by digital selenium radiography and analog screen film systems. Image quality of the digital pictures was rated significantly better. Conclusion: The use of digital selenium radiography in evaluating chest X-rays according to the ILO classification does not result in over- or underestimation of pulmonary pathologies. Hence, in the diagnosis of pneumoconiosis, digital selenium radiography can replace the tested analog screen-film system. (orig.) [German] Ziel: Zur Ermittlung des Stellenwertes der digitalen Selenradiographie in der Diagnostik von Staublungenerkrankungen werden mittels Selenradiographie und einer analogen Film-Folienkombination angefertigte Thoraxuebersichtsaufnahmen im sagittalen Strahlengang anhand der ILO-Klassifikation fuer Staublungenerkrankungen verglichen. Methoden: Nach Genehmigung der Studie durch die oertliche Ethikkommission und das Bundesamt fuer Strahlenschutz wurden bei 50 Patienten im Rahmen einer arbeitsmedizinischen Vorsorgeuntersuchung am selben Tag Thoraxuebersichtsaufnahmen im sagittalen Strahlengang in analoger und digitaler Technik (Thoravision; Philips Medizin Systeme, Hamburg, Deutschland

  9. Electrochemical immunosensor for the milk allergen β-lactoglobulin based on electrografting of organic film on graphene modified screen-printed carbon electrodes.

    Science.gov (United States)

    Eissa, Shimaa; Tlili, Chaker; L'Hocine, Lamia; Zourob, Mohammed

    2012-01-01

    A novel label-free voltammetric immunosensor for sensitive detection of β-lactoglobulin using graphene modified screen printed electrodes has been developed. The derivatization of the graphene electrode surface was achieved by electrochemical reduction of in situ generated 4-nitrophenyl diazonium cations in aqueous acidic solution, followed by electrochemical reduction of the terminal nitro groups to amines. The electrochemical modification protocol was optimized in order to generate monolayer of nitrophenyl groups on the graphene surface without complete passivation of the electrode. Unlike the reported method for graphene functionalization, we demonstrated here the ability of the electrografting of aryl diazonium salt to attach an organic film to the graphene surface in a controlled manner by choosing the suitable grafting protocol. Next, the amine groups on the graphene surface were activated using glutaraldehyde and used for the covalent immobilization of β-lactoglobulin antibodies. Cyclic and differential pulse voltammetry carried out in an aqueous solution containing [Fe(CN)(6)](3-/4-) redox pair have been used for the immunosensor characterization. The results demonstrated that the DPV reduction peak current of [Fe(CN)(6)](3-/4-) decreased linearly with increasing the concentration of β-lactoglobulin due to the formation of antibody-antigen complex on the modified electrode surface. The immunosensor obtained using this novel approach enabled a detection limit of 0.85 pg mL(-1) and a dynamic range from 1 pg mL(-1) to 100 ng mL(-1) of β-lactoglobulin in PBS buffer. In addition, the immunosensor evaluated in different samples including cake, cheese snacks, a sweet biscuit, showing excellent correlation with the results obtained from commercially enzyme-linked immunosorbent assay (ELISA) method. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. Effects of B2O3-Li2O additions on the dielectric properties of screen printing Ba0.6Sr0.4TiO3 thick films

    International Nuclear Information System (INIS)

    Zeng, Yike; Gao, Can; Zhang, Guangzu; Jiang, Shenglin

    2012-01-01

    Ba 0.6 Sr 0.4 TiO 3 (BST) thick films were fabricated on Al 2 O 3 substrate via the screen printing technology by using B 2 O 3 -Li 2 O additions as liquid-phase sintering aids. The effects of doping of B 2 O 3 and Li 2 CO 3 on the phase compositions, microstructures, and dielectric tunable properties of the thick films were investigated systematically. The X-ray diffraction patterns showed that BST diffraction peaks shifted toward higher angle with the B 2 O 3 -Li 2 O doping content, which indicated the substitution of B 3+ and Li + in Ba 2+ site. It was also found that the grain size and electrical properties of the thick film were strongly affected by the glass content. The grain size and the relative permittivity decreased obviously with the increase of B 2 O 3 -Li 2 O additive. In addition, for the thick film with 4.5 wt% glass content, optimized sintering, and electrical properties were obtained: the sintering temperature of 900 C, relative permittivity of 312 (at 10 kHz), dielectric loss of 0.0039, tunability of 16.2% (at 3 kV/mm). These good sintering and electrical properties indicate that BST thick film with B 2 O 3 -Li 2 O addition is benefit for the development of LTCC technology and tunable devices. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  11. Mammography with rare earth intensifying screens

    International Nuclear Information System (INIS)

    Maurer, H.J.; Goos, F.

    1987-01-01

    Screens basing on rare earth phosphors with suitable films green or blue sensitive may be used in mammography with grids without diagnostic losses. Highest definition will be obtained with medium densities on film. High-speed screens may reduce dose, but definition is poor. Best compromise between speed and high definition may be reached with relative low thickness of phosphor layers. A system of high definition films (Medichrome) and special rare earth screens give best results. (orig.) [de

  12. Mass screening in breast cancer

    International Nuclear Information System (INIS)

    Strax, P.

    1977-01-01

    Some questions about mass screening in breast cancer are answered it being concluded that: 1. mass screening for the detection of early breast cancer is the only means with proven potential for lowering the death rate of the disease; 2. mammography is an importante - if not the most important modality in mass screening; 3. new film - screen combinations generally available are capable of producing mammograms of excelent quality with radiation doses down to .1 rad into the body of breast. The risk of malignant changes from such dosage - even when given periodically is negligeable. New equipment, to be available, shortly, will use the new film - screen combinations in an automated manner with must reduce cost in time, filme, personnel and processing - of more than 50%. This would make mass screening more practical. (M.A.) [pt

  13. Buy, Borrow, or Steal? Film Access for Film Studies Students

    Science.gov (United States)

    Rodgers, Wendy

    2018-01-01

    Libraries offer a mix of options to serve the film studies curriculum: streaming video, DVDs on Reserve, and streaming DVDs through online classrooms. Some professors screen films and lend DVDs to students. But how do students obtain the films required for their courses? How would they prefer to do so? These are among the questions explored using…

  14. Depression Screening

    Science.gov (United States)

    ... Depression Screening Substance Abuse Screening Alcohol Use Screening Depression Screening (PHQ-9) - Instructions The following questions are ... this tool, there is also text-only version . Depression Screening - Manual Instructions The following questions are a ...

  15. Consequences of digital mammography in population-based breast cancer screening: initial changes and long-term impact on referral rates

    Energy Technology Data Exchange (ETDEWEB)

    Bluekens, Adriana M.J. [National Expert and Training Centre for Breast Cancer Screening, Nijmegen (Netherlands); St. Elisabeth Hospital, Department of Radiology, Tilburg (Netherlands); Karssemeijer, Nico [Radboud University Nijmegen Medical Centre, Department of Radiology, Nijmegen (Netherlands); Beijerinck, David; Deurenberg, Jan J.M. [Preventicon Screening Centre/Mid-West, Utrecht (Netherlands); Engen, Ruben E. van [National Expert and Training Centre for Breast Cancer Screening, Nijmegen (Netherlands); Broeders, Mireille J.M. [National Expert and Training Centre for Breast Cancer Screening, Nijmegen (Netherlands); Radboud University Nijmegen Medical Centre, Department of Epidemiology, Biostatistics and HTA, Nijmegen (Netherlands); Heeten, Gerard J. den [National Expert and Training Centre for Breast Cancer Screening, Nijmegen (Netherlands); Academic Medical Centre (AMC), Department of Radiology, Amsterdam (Netherlands)

    2010-09-15

    To investigate the referral pattern after the transition to full-field digital mammography (FFDM) in a population-based breast cancer screening programme. Preceding the nationwide digitalisation of the Dutch screening programme, an FFDM feasibility study was conducted. Detection and referral rates for FFDM and screen-film mammography (SFM) were compared for first and subsequent screens. Furthermore, radiological characteristics of referrals in digital screening were assessed. A total of 312,414 screening mammograms were performed (43,913 digital and 268,501 conventional), with 4,473 consecutive referrals (966 following FFDM). Initially the FFDM referral rate peaked, and many false-positive results were noted as a consequence of pseudolesions and increased detection of (benign) microcalcifications. A higher overall referral rate was observed in FFDM screening in both first and subsequent examinations (p <.001), with a significant increase in cancer detection (p =.010). As a result of initial inexperience with digital screening images implementing FFDM in a population-based breast cancer screening programme may lead to a strong, but temporary increase in referral. Dedicated training in digital screening for radiographers and screening radiologists is therefore recommended. Referral rates decrease and stabilise (learning curve effect) at a higher level than in conventional screening, yet with significantly enhanced cancer detection. (orig.)

  16. Consequences of digital mammography in population-based breast cancer screening: initial changes and long-term impact on referral rates.

    Science.gov (United States)

    Bluekens, Adriana M J; Karssemeijer, Nico; Beijerinck, David; Deurenberg, Jan J M; van Engen, Ruben E; Broeders, Mireille J M; den Heeten, Gerard J

    2010-09-01

    To investigate the referral pattern after the transition to full-field digital mammography (FFDM) in a population-based breast cancer screening programme. Preceding the nationwide digitalisation of the Dutch screening programme, an FFDM feasibility study was conducted. Detection and referral rates for FFDM and screen-film mammography (SFM) were compared for first and subsequent screens. Furthermore, radiological characteristics of referrals in digital screening were assessed. A total of 312,414 screening mammograms were performed (43,913 digital and 268,501 conventional), with 4,473 consecutive referrals (966 following FFDM). Initially the FFDM referral rate peaked, and many false-positive results were noted as a consequence of pseudolesions and increased detection of (benign) microcalcifications. A higher overall referral rate was observed in FFDM screening in both first and subsequent examinations (p < .001), with a significant increase in cancer detection (p = .010). As a result of initial inexperience with digital screening images implementing FFDM in a population-based breast cancer screening programme may lead to a strong, but temporary increase in referral. Dedicated training in digital screening for radiographers and screening radiologists is therefore recommended. Referral rates decrease and stabilise (learning curve effect) at a higher level than in conventional screening, yet with significantly enhanced cancer detection.

  17. Consequences of digital mammography in population-based breast cancer screening: initial changes and long-term impact on referral rates

    International Nuclear Information System (INIS)

    Bluekens, Adriana M.J.; Karssemeijer, Nico; Beijerinck, David; Deurenberg, Jan J.M.; Engen, Ruben E. van; Broeders, Mireille J.M.; Heeten, Gerard J. den

    2010-01-01

    To investigate the referral pattern after the transition to full-field digital mammography (FFDM) in a population-based breast cancer screening programme. Preceding the nationwide digitalisation of the Dutch screening programme, an FFDM feasibility study was conducted. Detection and referral rates for FFDM and screen-film mammography (SFM) were compared for first and subsequent screens. Furthermore, radiological characteristics of referrals in digital screening were assessed. A total of 312,414 screening mammograms were performed (43,913 digital and 268,501 conventional), with 4,473 consecutive referrals (966 following FFDM). Initially the FFDM referral rate peaked, and many false-positive results were noted as a consequence of pseudolesions and increased detection of (benign) microcalcifications. A higher overall referral rate was observed in FFDM screening in both first and subsequent examinations (p <.001), with a significant increase in cancer detection (p =.010). As a result of initial inexperience with digital screening images implementing FFDM in a population-based breast cancer screening programme may lead to a strong, but temporary increase in referral. Dedicated training in digital screening for radiographers and screening radiologists is therefore recommended. Referral rates decrease and stabilise (learning curve effect) at a higher level than in conventional screening, yet with significantly enhanced cancer detection. (orig.)

  18. Engineering aspects of Passavant screening

    International Nuclear Information System (INIS)

    Siddle, K.R.; Sharma, R.K.

    1978-01-01

    The Passavant screen was developed in Europe almost 30 years ago. The Passavant screen is a vertical traveling screen; however, the basic difference between the conventional vertical traveling screen and the Passavant screen is that in the conventional screen water passes through the front screen belt and then the back screen belt, whereas in the Passavant screen the water enters in between the two belts and passes laterally through either of the belts. Thus, theoretically, the screening surface of the Passavant screen is doubled as compared to the same size conventional vertical traveling screen. Various design and operational modifications of the Passavant screen are possible to yield optimum design and performance characteristics which make it amenable to installation at power plants for safe removal of not only fish but also smaller organisms such as fish eggs and larvae. In this paper, details of the screen design and operational characteristics are discussed with notes on how these features can be modified to suit site- and organism-specific requirements

  19. Industrial radiography with phosphor screens

    International Nuclear Information System (INIS)

    Broadhead, P.

    1981-01-01

    An experimental system that comprises a film of low silver content and a pair of high resolution phosphor intensifying screens and a commercial industrial X-ray film of similar speed are compared for image quality. It is concluded that the use of phosphor screens offers an increase in image quality when the information is limited by the graininess or quantum mottle of a radiograph which is frequently the case in practical radiography. (author)

  20. Film in concert

    OpenAIRE

    2017-01-01

    From the very beginning of cinema, music always played an important role in the history of filmmaking. Nonetheless, film music is judged by critics as a kind of low-grade art form. However, the majority of film score composers enjoyed a classical education and composed as well for the silver screen as for the concert hall. Film music also has its roots in the musical era of romanticism. Therefore, symphonic film scores can be regarded as program music in a broader sense. These scores were inf...

  1. Screening the Urban: An Analysis of the Urban Life and Subjectivities in the Assamese Films of Bhabendra Nath Saikia and Jahnu Barua

    Directory of Open Access Journals (Sweden)

    Minakshi Dutta

    2016-10-01

    Full Text Available Amidst the clichéd representations of the urban world in Indian cinema in post-independence times, where ‘the urban’ is often perceived as the inevitable vice, there are few directors in both mainstream and regional cinema of India who attempted to dwell on a more engaged and critical reading of the newly emerging urban world and subject in Indian contexts. Within the domain of the Assamese cinema, Bhabendra Nath Saikia and Jahnu Barua have been the two prolific serious film makers who are noted for such engagement of their films with urbanity. This paper aims to describe, analyze and compare the characteristics of the cinematic projections of the urban life and urban subjectivities in the films of Saikia and Barua.

  2. Rock Goes to School on Screen: A Model for Teaching Non-"Learned" Musics Derived from the Films "School of Rock" (2003) and "Rock School" (2005)

    Science.gov (United States)

    Webb, Michael

    2007-01-01

    What can be learned from two films with "rock" and "school" in their titles, about rock in school and about music and schooling more broadly? "School of Rock" (2003), a "family comedy," and "Rock School" (2005), a documentary, provoke a range of questions, ideological and otherwise, surrounding the inclusion of rock in formal instructional…

  3. Luminescent properties and energy transfer processes in Ce-Tb doped single crystalline film screens of Lu-based silicate, perovskite and garnet compounds

    Czech Academy of Sciences Publication Activity Database

    Zorenko, Y.; Gorbenko, V.; Savchyn, V.; Zorenko, T.; Martin, T.; Douissard, P.-A.; Nikl, Martin; Mareš, Jiří A.

    2013-01-01

    Roč. 56, Sept (2013), s. 415-419 ISSN 1350-4487 Institutional support: RVO:68378271 Keywords : single crystalline films * liquid phase epitaxy * perovskites * luminescence * scintillators Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.140, year: 2013

  4. Making Movies: From Script to Screen.

    Science.gov (United States)

    Bobker, Lee R.

    This book is a guide to the making of films. It covers preparation (scripting, storyboarding, budgeting, casting, and crew selection), filming (directing, camera operating, and sound recording), and postproduction (editing, sound dubbing, laboratory processing, and trial screening). Distribution of films is discussed in detail. Possible careers in…

  5. Radiographic intensifying screens

    International Nuclear Information System (INIS)

    Van Landeghem, W.K.; Suys, A.R.

    1979-01-01

    A fluorescent x-ray image intensifying screen is described which comprises discrete particles of fluorescent material dispersed in a binder layer. Intensifying screens are employed to increase the exposure of a photosensitive plate or film without increasing the x-ray exposure dose when struck by x-rays. The screen has an outermost layer containing solid particulate material protruding from a coherent film-forming organic binder medium and having a static friction coefficient at room temperature not higher than 0.50 on steel. The outermost layer may be characterized by micro-unevennesses of at least 3 μm and at least 9 protruding particles per 0.35 sq. cm. These particles have a static friction coefficient less than 0.3 and are made of a solid polystyrene, polyaklylene and/or a solid organic fluorinated polymer. (JTA)

  6. Video enhancement of dental radiographic films

    International Nuclear Information System (INIS)

    Van Dis, M.L.; Beck, F.M.; Miles, D.A.

    1989-01-01

    A prototype video image display system, a real-time analog enhancer (RAE), was compared to conventional viewing conditions with the use of nonscreen dental films. When medium optical density films were evaluated, there was no significant difference in the number of radiographic details detected. Conventional viewing conditions allowed perception of more details when dark films were evaluated; however, the RAE unit allowed the perception of more details when light films were viewed

  7. Fire resistant films for aircraft applications

    Science.gov (United States)

    Kourtides, D. A.

    1983-01-01

    Alternative sandwich panel decorative films were investigated as replacements for the polyvinyl fluoride currently used in aircraft interiors. Candidate films were studied for flammability, smoke emission, toxic gas emission, flame spread, and suitability as a printing surface for the decorative acrylic ink system. Several of the candidate films tested were flame modified polyvinyl fluoride, polyvinylidene fluoride, polyimide, polyamide, polysulfone, polyphenylsulfone, polyethersulfone, polybenzimidazole, polycarbonate, polyparabanic acid, polyphosphazene, polyetheretherketon, and polyester. The films were evaluated as pure films only, films silk-screened with an acrylic ink, and films adhered to a phenolic fiberglass substrate. Films which exhibited the highest fire resistant properties included PEEK polyetheretherketon, Aramid polyamide, and ISO-BPE polyester.

  8. Chemical Weapons Convention

    National Research Council Canada - National Science Library

    1997-01-01

    On April 29, 1997, the Convention on the Prohibition of the Development, Production, Stockpiling, and Use of Chemical Weapons and on Their Destruction, known as the Chemical Weapons Convention (CWC...

  9. The Hague Judgments Convention

    DEFF Research Database (Denmark)

    Nielsen, Peter Arnt

    2011-01-01

    The Hague Judgments Convention of 2005 is the first global convention on international jurisdiction and recognition and enforcement of judgments in civil and commercial matters. The author explains the political and legal background of the Convention, its content and certain crucial issues during...

  10. Films Deliver: Teaching Creatively with Film.

    Science.gov (United States)

    Schillaci, Anthony, Ed.; Culkin, John M., Ed.

    The fifteen papers in this resource guide are grouped into four sections. Section one contains formulations of the basic rationale for screen education and descriptions of new concepts and approaches to film study. Section two presents a definition of the elements involved in filmmaking and viewing, and it describes several model programs which…

  11. Cost-effectiveness of conventional cytology and HPV DNA testing for cervical cancer screening in Colombia Costo-efectividad de la citología y la tamización con pruebas de ADN-VPH para cáncer de cuello uterino en Colombia

    Directory of Open Access Journals (Sweden)

    Oscar Andrés-Gamboa

    2008-08-01

    Full Text Available OBJECTIVE: To assess cost-effectiveness of conventional cytology and HPV DNA testing for cervical-cancer screening in Colombia. MATERIAL AND METHODS: The National Cancer Institute of Colombia (NCIC in 2007 developed a Markov model on the natural history of cervical cancer; no screening, conventional cytology, and HPV DNA testing were compared. Only direct costs were used. Outcomes comprise cervical cancer mortality, years of life saved, and lifetime costs. Discounted incremental cost-effectiveness ratios were estimated and sensitivity analyses were conducted for key parameters. RESULTS: Depending on the screening strategy a 69-81% mortality reduction might be expected. The HPV DNA testing every five years is a cost-effective strategy (Incremental Cost-Effectiveness Ratio (ICER: USD$44/YLS if the cost per test is under USD$31. The effectiveness was sensitive to coverage and primarily to follow-up. CONCLUSIONS: HPV DNA testing is a cost-effective alternative for screening in Colombia. Not only high coverage but high follow-up rates are critical for successful screening programs.OBJETIVO: evaluar el costo-efectividad de la citología convencional y la prueba de ADN-VPH para tamización de cáncer cervical en Colombia. MATERIAL Y MÉTODOS: el Instituto Nacional de Cancerología de Colombia construyó en 2007 un modelo de Markov de historia natural del cáncer cervical. Se comparó "no tamización", citología convencional y prueba de ADN-VPH. Se utilizaron costos directos. Los desenlaces fueron mortalidad, años de vida ganados y costos. Se calcularon razones de costo-efectividad incremental. Se realizaron análisis de sensibilidad para parámetros clave. RESULTADOS: la mortalidad se redujo 69-81% según la estrategia. La tamización con ADN-VPH cada cinco años es costo-efectiva (ICER (Razón de Costo-Efectividad incremental por sus siglas en inglés: 44 dólares por año de vida saludable si los costos por prueba son menores a 31 dólares. La

  12. [Oral films as perspective dosage form].

    Science.gov (United States)

    Walicová, Veronika; Gajdziok, Jan

    Oral films, namely buccal mucoadhesive films and orodispersible films represent innovative formulations for administration of a wide range of drugs. Oral films show many advantageous properties and are intended for systemic drug delivery or for local treatment of the oral mucosa. In both cases, the film represents a thin layer, which could be intended to adhere to the oral mucosa by means of mucoadhesion; or to rapid dissolution and subsequent swallowing without the need of liquid intake, in the case of orodispersible films. Main constitutive excipients are film-forming polymers, which must in the case of mucoadhesive forms remain on the mucosa within the required time interval. Oral films are currently available on the pharmaceutical market and could compete with conventional oral dosage forms in the future. oral cavity oral films buccal mucoadhesive films orodispersible films film-forming polymers.

  13. High-throughput combinatorial chemical bath deposition: The case of doping Cu (In, Ga) Se film with antimony

    Science.gov (United States)

    Yan, Zongkai; Zhang, Xiaokun; Li, Guang; Cui, Yuxing; Jiang, Zhaolian; Liu, Wen; Peng, Zhi; Xiang, Yong

    2018-01-01

    The conventional methods for designing and preparing thin film based on wet process remain a challenge due to disadvantages such as time-consuming and ineffective, which hinders the development of novel materials. Herein, we present a high-throughput combinatorial technique for continuous thin film preparation relied on chemical bath deposition (CBD). The method is ideally used to prepare high-throughput combinatorial material library with low decomposition temperatures and high water- or oxygen-sensitivity at relatively high-temperature. To check this system, a Cu(In, Ga)Se (CIGS) thin films library doped with 0-19.04 at.% of antimony (Sb) was taken as an example to evaluate the regulation of varying Sb doping concentration on the grain growth, structure, morphology and electrical properties of CIGS thin film systemically. Combined with the Energy Dispersive Spectrometer (EDS), X-ray Photoelectron Spectroscopy (XPS), automated X-ray Diffraction (XRD) for rapid screening and Localized Electrochemical Impedance Spectroscopy (LEIS), it was confirmed that this combinatorial high-throughput system could be used to identify the composition with the optimal grain orientation growth, microstructure and electrical properties systematically, through accurately monitoring the doping content and material composition. According to the characterization results, a Sb2Se3 quasi-liquid phase promoted CIGS film-growth model has been put forward. In addition to CIGS thin film reported here, the combinatorial CBD also could be applied to the high-throughput screening of other sulfide thin film material systems.

  14. Screening the modern girl: intermediality in the adaptation of "Flaming Youth".

    Science.gov (United States)

    Ross, Sara

    2010-01-01

    In the early 1920s, the film industry seized on the furor over the modern girls' demands for sexual liberty and fulfillment inside and outside of marriage to introduce not only new subject matter, but new modes of addressing its diverse audience. Social upheaval in this period coincided with the media industries' movement toward unprecedented speed of adaptation and cooperation, making possible a powerful new intermediality. The film industry used this to generate layered meanings beyond the confines of the film text, encouraging bold viewers to see through the camouflage with which it sought to appease more traditionalist audience members. With Flaming Youth, through a smokescreen of melodramatic conventions and moral lessons, it delivered a strikingly modern conception of sexuality and marriage to the big screen.

  15. Film Reviews.

    Science.gov (United States)

    Lance, Larry M.; Atwater, Lynn

    1987-01-01

    Reviews four Human Sexuality films and videos. These are: "Personal Decisions" (Planned Parenthood Federation of America, 1985); "The Touch Film" (Sterling Production, 1986); "Rethinking Rape" (Film Distribution Center, 1985); "Not A Love Story" (National Film Board of Canada, 1981). (AEM)

  16. Silver-Nanoparticle-Based Screen-Printing and Film Characterization of a Disposable, Dual-Band, Bandstop Filter on a Flexible Polyethylene Terephthalate Substrate

    Directory of Open Access Journals (Sweden)

    Kishor Kumar Adhikari

    2015-01-01

    Full Text Available This paper presents a silver-nanoparticle-based, screen-printed, high-performance, dual-band, bandstop filter (DBBSF on a flexible polyethylene terephthalate (PET substrate. Using screen-printing techniques to process a highly viscous silver printing ink, high-conductivity printed lines were implemented at a web transfer speed of 5 m/min. Characterized by X-ray diffraction (XRD, optical microscopy, atomic force microscopy (AFM, and scanning electron microscopy (SEM, the printed lines were shown to be characterized by smooth surfaces with a root mean square roughness of 7.986 nm; a significantly higher thickness (12.2 μm than the skin depth; and a high conductivity of 2×107 S/m. These excellent printed line characteristics enabled the implementation of a high-selectivity DBBSF using shunt-connected uniform impedance resonators (UIRs. Additionally, the inductive loading effect of T-shaped stubs on the UIRs, which were analyzed using S-parameters based on lumped parameter calculations, was used to improve the return losses of the geometrically optimized DBBSF. The measured minimum return loss and maximum insertion loss of 28.26 and 1.58 dB, respectively, at the central frequencies of 2.56 and 5.29 GHz of a protocol screen-printed DBBSF demonstrated the excellent performance of the material and its significant potential for use in future cost-effective, flexible WiMax and WLAN applications.

  17. Evaluation of average glandular dose in digital and conventional systems of the mammography

    International Nuclear Information System (INIS)

    Xavier, Aline C.S.; Barros, Vinicius S.M.; Khoury, Hellen J.

    2014-01-01

    Mammography is currently the most effective method of diagnosis and detection of breast pathologies. The main interest in this kid of exam comes from the high incidence rate of breast cancer and necessity of high quality images for accurate diagnosis. Digital mammography systems have several advantages compared to conventional systems, however the use of digital imaging systems is not always integrated to an image acquisition protocol. Therefore, it is questionable if digital systems truly reduce the dose received by the patient, because many times is introduced in the clinics without optimization of the image acquisition protocols. The aim of this study is to estimate the value of incident air Kerma and average glandular dose (AGD) in patients undergoing conventional and digital mammography systems in Recife. This study was conducted with 650 patients in three hospitals. The value of incident air Kerma was estimated from the measurement of the yield of equipment and irradiation parameters used for each patient. From these results and using the methodology proposed by Dance et al. the value of the average glandular dose was calculated. The results obtained show that the lowest value of AGD was found with conventional screen-film system, indicating that the parameters for image acquisition with digital systems are not optimized. It was also observed that the institutions with digital systems use lower breast compression values than the conventional. (author)

  18. Film Language: A Student-Made Dictionary.

    Science.gov (United States)

    Poteet, G. Howard

    1967-01-01

    The failure of verbal descriptions to convey an understanding of film terminology led to a student production of a 20-minute color film that defines various film methods by illustrating them. A technique is shown on the screen and simultaneous soundtrack narration explains how this technique can be used. When the narration lasts longer than the…

  19. doped ZnO thick film resistors

    Indian Academy of Sciences (India)

    The characterization and ethanol gas sensing properties of pure and doped ZnO thick films were investigated. Thick films of pure zinc oxide were prepared by the screen printing technique. Pure zinc oxide was almost insensitive to ethanol. Thick films of Al2O3 (1 wt%) doped ZnO were observed to be highly sensitive to ...

  20. Special equipment for etching nitrocellulose film

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1983-08-01

    Nitrocellulose film and converter screens used for neutron radiography are described. Difficulties in visualization of radiographs on those films are mentioned. Because there is no equipment for etching nitrocellulose film available on the market Risoe has designed and produced such equipment at an estimated cost of Dkr. 15,000. Design criteria for this equipment are given and its performance described

  1. Staging the Amateur Film Dispositif (video)

    NARCIS (Netherlands)

    van der Heijden, T.

    2014-01-01

    A media archaeological experiment performed on March 31st 2014, at the 9th International Orphan Film Symposium, EYE Film Institute Amsterdam. In the performance we reconstruct the changing 'dispositif' of home movie screening practices. In three ‘tableaux’ we explore how past media usages of film,

  2. Screening of Six Medicinal Plant Extracts Obtained by Two Conventional Methods and Supercritical CO₂ Extraction Targeted on Coumarin Content, 2,2-Diphenyl-1-picrylhydrazyl Radical Scavenging Capacity and Total Phenols Content.

    Science.gov (United States)

    Molnar, Maja; Jerković, Igor; Suknović, Dragica; Bilić Rajs, Blanka; Aladić, Krunoslav; Šubarić, Drago; Jokić, Stela

    2017-02-24

    Six medicinal plants Helichrysum italicum (Roth) G. Don, Angelica archangelica L., Lavandula officinalis L., Salvia officinalis L., Melilotus officinalis L., and Ruta graveolens L. were used. The aim of the study was to compare their extracts obtained by Soxhlet (hexane) extraction, maceration with ethanol (EtOH), and supercritical CO₂ extraction (SC-CO₂) targeted on coumarin content (by high performance liquid chromatography with ultraviolet detection, HPLC-UV), 2,2-diphenyl-1-picrylhydrazyl radical (DPPH) scavenging capacity, and total phenols (TPs) content (by Folin-Ciocalteu assay). The highest extraction yields were obtained by EtOH, followed by hexane and SC-CO₂. The highest coumarin content (316.37 mg/100 g) was found in M. officinalis EtOH extracts, but its SC-CO₂ extraction yield was very low for further investigation. Coumarin was also found in SC-CO₂ extracts of S. officinalis , R. graveolens , A. archangelica , and L. officinalis . EtOH extracts of all plants exhibited the highest DPPH scavenging capacity. SC-CO₂ extracts exhibited antiradical capacity similar to hexane extracts, while S. officinalis SC-CO₂ extracts were the most potent (95.7%). EtOH extracts contained the most TPs (up to 132.1 mg gallic acid equivalents (GAE)/g from H. italicum ) in comparison to hexane or SC-CO₂ extracts. TPs content was highly correlated to the DPPH scavenging capacity of the extracts. The results indicate that for comprehensive screening of different medicinal plants, various extraction techniques should be used in order to get a better insight into their components content or antiradical capacity.

  3. Screening of Six Medicinal Plant Extracts Obtained by Two Conventional Methods and Supercritical CO2 Extraction Targeted on Coumarin Content, 2,2-Diphenyl-1-picrylhydrazyl Radical Scavenging Capacity and Total Phenols Content

    Directory of Open Access Journals (Sweden)

    Maja Molnar

    2017-02-01

    Full Text Available Six medicinal plants Helichrysum italicum (Roth G. Don, Angelica archangelica L., Lavandula officinalis L., Salvia officinalis L., Melilotus officinalis L., and Ruta graveolens L. were used. The aim of the study was to compare their extracts obtained by Soxhlet (hexane extraction, maceration with ethanol (EtOH, and supercritical CO2 extraction (SC-CO2 targeted on coumarin content (by high performance liquid chromatography with ultraviolet detection, HPLC-UV, 2,2-diphenyl-1-picrylhydrazyl radical (DPPH scavenging capacity, and total phenols (TPs content (by Folin–Ciocalteu assay. The highest extraction yields were obtained by EtOH, followed by hexane and SC-CO2. The highest coumarin content (316.37 mg/100 g was found in M. officinalis EtOH extracts, but its SC-CO2 extraction yield was very low for further investigation. Coumarin was also found in SC-CO2 extracts of S. officinalis, R. graveolens, A. archangelica, and L. officinalis. EtOH extracts of all plants exhibited the highest DPPH scavenging capacity. SC-CO2 extracts exhibited antiradical capacity similar to hexane extracts, while S. officinalis SC-CO2 extracts were the most potent (95.7%. EtOH extracts contained the most TPs (up to 132.1 mg gallic acid equivalents (GAE/g from H. italicum in comparison to hexane or SC-CO2 extracts. TPs content was highly correlated to the DPPH scavenging capacity of the extracts. The results indicate that for comprehensive screening of different medicinal plants, various extraction techniques should be used in order to get a better insight into their components content or antiradical capacity.

  4. Barrier Performance of CVD Graphene Films Using a Facile P3HT Thin Film Optical Transmission Test

    Directory of Open Access Journals (Sweden)

    Srinivasa Kartik Nemani

    2018-01-01

    Full Text Available The barrier performance of CVD graphene films was determined using a poly(3-hexylthiophene (P3HT thin film optical transmission test. P3HT is a semiconducting polymer that photo-oxidatively degrades upon exposure to oxygen and light. The polymer is stable under ambient conditions and indoor lighting, enabling P3HT films to be deposited and encapsulated in air. P3HT’s stability under ambient conditions makes it desirable for an initial evaluation of barrier materials as a complimentary screening method in combination with conventional barrier tests. The P3HT test was used to demonstrate improved barrier performance for polymer substrates after addition of CVD graphene films. A layer-by-layer transfer method was utilized to enhance the barrier performance of monolayer graphene. Another set of absorption measurements were conducted to demonstrate the barrier performance of graphene and the degradation mechanism of graphene/P3HT over multiple wavelengths from 400 to 800 nm. The absorption spectra for graphene/polymer composite were simulated by solving Fresnel equations. The simulation results were found to be in good agreement with the measured absorption spectra. The P3HT degradation results qualitatively indicate the potential of graphene films as a possible candidate for medium performance barriers.

  5. Convention on nuclear safety

    International Nuclear Information System (INIS)

    1994-01-01

    The Convention on Nuclear Safety was adopted on 17 June 1994 by Diplomatic Conference convened by the International Atomic Energy Agency at its Headquarters from 14 to 17 June 1994. The Convention will enter into force on the ninetieth day after the date of deposit with the Depository (the Agency's Director General) of the twenty-second instrument of ratification, acceptance or approval, including the instruments of seventeen States, having each at leas one nuclear installation which has achieved criticality in a reactor core. The text of the Convention as adopted is reproduced in the Annex hereto for the information of all Member States

  6. A new test phantom with different breast tissue compositions for image quality assessment in conventional and digital mammography

    International Nuclear Information System (INIS)

    Pachoud, Marc; Lepori, D; Valley, Jean-Francois; Verdun, Francis R

    2004-01-01

    Our objective is to describe a new test phantom that permits the objective assessment of image quality in conventional and digital mammography for different types of breast tissue. A test phantom, designed to represent a compressed breast, was made from tissue equivalent materials. Three separate regions, with different breast tissue compositions, are used to evaluate low and high contrast resolution, spatial resolution and image noise. The phantom was imaged over a range of kV using a Contour 2000 (Bennett) mammography unit with a Kodak MinR 2190-MinR L screen-film combination and a Senograph 2000D (General Electric) digital mammography unit. Objective image quality assessments for different breast tissue compositions were performed using the phantom for conventional and digital mammography. For a similar mean glandular dose (MGD), the digital system gives a significantly higher contrast-to-noise ratio (CNR) than the screen-film system for 100% glandular tissue. In conclusion, in mammography, a range of exposure conditions is used for imaging because of the different breast tissue compositions encountered clinically. Ideally, the patient dose-image quality relationship should be optimized over the range of exposure conditions. The test phantom presented in this work permits image quality parameters to be evaluated objectively for three different types of breast tissue. Thus, it is a useful tool for optimizing the patient dose-image quality relationship

  7. Polyvinylidene fluoride film as a capacitor dielectric

    Science.gov (United States)

    Dematos, H. V.

    1981-01-01

    Thin strips of polyvinylidene fluoride film (PVDF) with vacuum deposited electrodes were made into capacitors by conventional winding and fabrication techniques. These devices were used to identify and evaluate the performance characteristics offered by the PVDF in metallized film capacitors. Variations in capacitor parameters with temperature and frequence were evaluated and compared with other dielectric films. Their impact on capacitor applications is discussed.

  8. Miniaturized, Planar Ion-selective Electrodes Fabricated by Means of Thick-film Technology

    Directory of Open Access Journals (Sweden)

    Robert Koncki

    2006-04-01

    Full Text Available Various planar technologies are employed for developing solid-state sensorshaving low cost, small size and high reproducibility; thin- and thick-film technologies aremost suitable for such productions. Screen-printing is especially suitable due to itssimplicity, low-cost, high reproducibility and efficiency in large-scale production. Thistechnology enables the deposition of a thick layer and allows precise pattern control.Moreover, this is a highly economic technology, saving large amounts of the used inks. Inthe course of repetitions of the film-deposition procedure there is no waste of material dueto additivity of this thick-film technology. Finally, the thick films can be easily and quicklydeposited on inexpensive substrates. In this contribution, thick-film ion-selective electrodesbased on ionophores as well as crystalline ion-selective materials dedicated forpotentiometric measurements are demonstrated. Analytical parameters of these sensors arecomparable with those reported for conventional potentiometric electrodes. All mentionedthick-film strip electrodes have been totally fabricated in only one, fully automated thick-film technology, without any additional manual, chemical or electrochemical steps. In allcases simple, inexpensive, commercially available materials, i.e. flexible, plastic substratesand easily cured polymer-based pastes were used.

  9. Minamata Convention on Mercury

    Science.gov (United States)

    On November 6, 2013 the United States signed the Minamata Convention on Mercury, a new multilateral environmental agreement that addresses specific human activities which are contributing to widespread mercury pollution

  10. Advances in cervical screening technology.

    Science.gov (United States)

    Stoler, M H

    2000-03-01

    The Pap smear unquestionably is a successful screening test for cervical cancer. However, recent advances in technology have raised questions regarding whether the conventional Pap smear is still the standard of care. This article relates issues of screening and cost-effectiveness to the state of the art in thin layer preparations, cytology automation, human papillomavirus screening, human papillomavirus vaccines, and other cervical screening adjuncts. Perhaps nowhere in medicine is clinical decision making being more strongly influenced by market and other external forces than in cervical cytopathology.

  11. Toxicology screen

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003578.htm Toxicology screen To use the sharing features on this page, please enable JavaScript. A toxicology screen refers to various tests that determine the ...

  12. Climate change convention

    International Nuclear Information System (INIS)

    Russell, D.

    1992-01-01

    Principles that guide Canada's Green Plan with respect to global warming are outlined. These include respect for nature, meeting environmental goals in an economically beneficial manner, efficient use of resources, shared responsibilities, federal leadership, and informed decision making. The policy side of the international Framework Convention on Climate Change is then discussed and related to the Green Plan. The Convention has been signed by 154 nations and has the long-term objective of stabilizing anthropogenic greenhouse gas concentrations in the atmosphere at levels that prevent dangerous interference with the climate system. Some of the Convention's commitments toward achieving that objective are only applicable to the developed countries. Five general areas of commitment are emissions reductions, assistance to developing countries, reporting requirements, scientific and socioeconomic research, and education. The most controversial area is that of limiting emissions. The Convention has strong measures for public accountability and is open to future revisions. Canada's Green Plan represents one country's response to the Convention commitments, including a national goal to stabilize greenhouse gas emissions at the 1990 level by the year 2000

  13. Comparative study between computed radiography and conventional radiography

    International Nuclear Information System (INIS)

    Noorhazleena Azaman; Khairul Anuar Mohd Salleh; Sapizah Rahim; Shaharudin Sayuti; Arshad Yassin; Abdul Razak Hamzah

    2010-01-01

    In Industrial Radiography, there are many criteria that need to be considered based on established standards to accept or reject the radiographic film. For conventional radiography, we need to consider the optical density by using the densitometer when viewing the film on the viewer. But in the computed radiography (CR) we need to evaluate and performed the analysis from the quality of the digital image through grey value. There are many factors that affected the digital image quality. One of the factors which are affected to the digital image quality in the image processing is grey value that related to the contrast resolution. In this work, we performed grey value study measurement on digital radiography systems and compared it with exposed films in conventional radiography. The test sample is a steel step wedge. We found out the contrast resolution is higher in Computed Radiography compared with Conventional Radiography. (author)

  14. Screen violence and youth behavior

    NARCIS (Netherlands)

    Anderson, Craig A.; Bushman, Brad J.; Bartholow, Bruce D.; Cantor, Joanne; Christakis, Dimitri; Coyne, Sarah M.; Donnerstein, Edward; Brockmyer, Jeanne Funk; Gentile, Douglas A.; Green, C. Shawn; Huesmann, Rowell; Hummer, Tom; Krahé, Barbara; Strasburger, Victor C.; Warburton, Wayne; Wilson, Barbara J.; Ybarra, Michele

    2017-01-01

    Violence in screen entertainment media (ie, television, film, video games, and the Internet), defined as depictions of characters (or players) trying to physically harm other characters (or players), is ubiquitous. The Workgroup on Media Violence and Violent Video Games reviewed numerous

  15. Tritium and OSPAR convention

    International Nuclear Information System (INIS)

    2009-01-01

    The missions and the organisation of the OSPAR convention on protection of the NE Atlantic marine environment are given. The OSPAR strategy for the radioactive substances is stated. The results of work programme of the radioactive Substances committee are described and the consensus reached by contracting parties on the appropriate arrangements for this radionuclide is presented. (authors)

  16. Revised C++ coding conventions

    CERN Document Server

    Callot, O

    2001-01-01

    This document replaces the note LHCb 98-049 by Pavel Binko. After a few years of practice, some simplification and clarification of the rules was needed. As many more people have now some experience in writing C++ code, their opinion was also taken into account to get a commonly agreed set of conventions

  17. Global climate convention

    International Nuclear Information System (INIS)

    Simonis, U.E.

    1991-01-01

    The effort of negotiate a global convention on climate change is one of mankind's great endeavours - and a challenge to economists and development planners. The inherent linkages between climate and the habitability of the earth are increasingly well recognized, and a convention could help to ensure that conserving the environment and developing the economy in the future must go hand in hand. Due to growing environmental concern the United Nations General Assembly has set into motion an international negotiating process for a framework convention on climate change. One the major tasks in these negotiations is how to share the duties in reducing climate relevant gases, particularly carbon dioxide (CO 2 ), between the industrial and the developing countries. The results and proposals could be among the most far-reaching ever for socio-economic development, indeed for global security and survival itself. While the negotiations will be about climate and protection of the atmosphere, they will be on fundamental global changes in energy policies, forestry, transport, technology, and on development pathways with low greenhouse gas emissions. Some of these aspects of a climate convention, particularly the distributional options and consequences for the North-South relations, are addressed in this chapter. (orig.)

  18. Digital vs conventional radiography: cost and revenue analysis

    International Nuclear Information System (INIS)

    Dalla Palma, L.; Cuttin, R.; Rimondini, A.; Grisi, G.

    1999-01-01

    The objective of this study was to analyse and compare the operating and investment costs of two radiographic systems, a conventional and a digital one, and to evaluate the cost/revenue ratio of the two systems. The radiological activity over 1 year for chest and skeletal exams was evaluated: 13,401 chest and 7,124 skeletal exams were considered. The following parameters of variable costs were evaluated: the difference between variable proportional costs of the two technologies, the effective variable cost of any size film, including the chemicals, and for different sizes of digital film, variable costs of chest plus skeletal exams performed with the two techniques. Afterwards the economical effect was considered taking into account depreciation during a time of utilization ranging between 8 and 4 years. In the second part of the analysis the total cost and the revenues of the two technologies were determined. The comparison between the digital and conventional systems has shown the following aspects: 1. Digital radiography system has a much higher investment cost in comparison with the conventional one. 2. Operating costs of digital equipment are higher or lower depending on the film size used. Evaluating chest X-ray we reach a breakeven point after 1 year and 10,000 exams only if displayed over 8 x 10-in. film and after 30,000 if displayed over a 11 x 14-in. film. 3. The total cost (variable cost, technology cost, labour cost) of digital technology is lower than that of the conventional system by 20 % on average using 8 x 10-in. film size. 4. Digital technology also allows lesser film waste and lesser film per exam (orig.)

  19. Colon cancer screening

    Science.gov (United States)

    Screening for colon cancer; Colonoscopy - screening; Sigmoidoscopy - screening; Virtual colonoscopy - screening; Fecal immunochemical test; Stool DNA test; sDNA test; Colorectal cancer - screening; Rectal ...

  20. Laser Based Color Film Recorder System With GaAs Microlaser

    Science.gov (United States)

    Difrancesco, David J.

    1989-07-01

    In 1984 Pixar's research and development group built and applied to the motion-picture arts at Lucasfilm's ILM facility a three color laser based film scanner/recorder system. The digital film printer is capable of reading and writing 35mm film formats on a variety of film stocks. The system has been used in award-winning special-effects work, and has been operated in a normal production environment since that time. The primary objective was to develop a full color high resolution system, free from scan artifacts, enabling traditionally photographed motion-picture film to be inter-cut with digital raster image photography. Its use is applied to the art of blue-screen traveling-matte cinematography for motion pic-ture special effects. The system was designed using the Pixar Image Computer and conventional gas laser technology as the illumination source. This paper will discuss recent experimental work in the application of GaAs microlaser technology to a digital film printing system of the future.

  1. Conventions and Institutional Logics

    DEFF Research Database (Denmark)

    Westenholz, Ann

    Two theoretical approaches – Conventions and Institutional Logics – are brought together and the similarities and differences between the two are explored. It is not the intention to combine the approaches, but I would like to open both ‘boxes’ and make them available to each other with the purpose...... of creating a space for dialog. Both approaches were developed in the mid-1980s as a reaction to rational-choice economic theory and collectivistic sociological theory. These two theories were oversimplifying social life as being founded either in actor-micro level analyses or in structure-macro level...... analyses. The theoretical quest of both Conventions and Institutional Logics has been to understand the increasing indeterminacy, uncertainty and ambiguity in people’s lives where a sense of reality, of value, of moral, of feelings is not fixed. Both approaches have created new theoretical insights...

  2. Projekce artových filmů v multikině Cinestar Anděl

    OpenAIRE

    Kafuňková, Martina

    2011-01-01

    The Bachelor Thesis "Screening art house movies in the multiplex Cinestar Andel" deals with the role of art house movies in the multiplex Cinestar Andel. The theoretical part describes the terms "art house film", "multiplex" and "film festival". It also shows the possibilities of screening art house films. The question of the impact of digitalization on the distribution of Art House films is also considered. The practical part focuses on current examples of screening art house films, namely F...

  3. Manado Convention Centre (Megastructures)

    OpenAIRE

    Anggianto, Rio M; Rate, Johannes Van

    2013-01-01

    Proyek Manado Convention Center ini pada dasarnya merupakan wadah atau sarana komunikasi antara dua pihak dengan penerapkan berbagai metode komunikasi langsung tatap muka baik itu dari perorangan terhadap kelompok, kelompok terhadap kelompok atau kelompok terhadap masyarakat. Dan pada era kini hal ini menjadi suatu kebutuhan yang dianganggap penting. Kota Manado seringkali menjadi tuan rumah suatu konverensi dengan jumlah peserta yang tergolong besar karena cakupannya sampai manca negara....

  4. The conventional quark picture

    International Nuclear Information System (INIS)

    Dalitz, R.H.

    1976-01-01

    For baryons, mesons and deep inelastic phenomena the ideas and the problems of the conventional quark picture are pointed out. All observed baryons fit in three SU(3)-multiplets which cluster into larger SU(6)-multiplets. No mesons are known which have quantum numbers inconsistent with belonging to a SU(3) nonet or octet. The deep inelastic phenomena are described in terms of six structure functions of the proton. (BJ) [de

  5. Landfill waste and recycling: Use of a screening-level risk assessment tool for end-of-life cadmium telluride (CdTe) thin-film photovoltaic (PV) panels

    International Nuclear Information System (INIS)

    Cyrs, William D.; Avens, Heather J.; Capshaw, Zachary A.; Kingsbury, Robert A.; Sahmel, Jennifer; Tvermoes, Brooke E.

    2014-01-01

    Grid-connected solar photovoltaic (PV) power is currently one of the fastest growing power-generation technologies in the world. While PV technologies provide the environmental benefit of zero emissions during use, the use of heavy metals in thin-film PV cells raises important health and environmental concerns regarding the end-of-life disposal of PV panels. To date, there is no published quantitative assessment of the potential human health risk due to cadmium leaching from cadmium telluride (CdTe) PV panels disposed in a landfill. Thus, we used a screening-level risk assessment tool to estimate possible human health risk associated with disposal of CdTe panels into landfills. In addition, we conducted a literature review of potential cadmium release from the recycling process in order to contrast the potential health risks from PV panel disposal in landfills to those from PV panel recycling. Based on the results of our literature review, a meaningful risk comparison cannot be performed at this time. Based on the human health risk estimates generated for PV panel disposal, our assessment indicated that landfill disposal of CdTe panels does not pose a human health hazard at current production volumes, although our results pointed to the importance of CdTe PV panel end-of-life management. - Highlights: • Analysis of possible human health risk posed by disposal of CdTe panels into landfills. • Qualitative comparison of risks associated with landfill disposal and recycling of CdTe panels. • Landfill disposal of CdTe panels does not pose a human health hazard at current production volumes. • There could be potential risks associated with recycling if not properly managed. • Factors other than concerns over toxic substances will likely drive the decisions of how to manage end-of-life PV panels

  6. Coming to Life: A Review of Movie Comics: Page to Screen/Screen to Page

    OpenAIRE

    Labarre, Nicolas

    2017-01-01

    This book review provides an overview of 'Movie Comics: Page to Screen/Screen to Page' by Blair Davis (Rutgers University Press, 2017) a book which examines the reciprocal adaptations of film into comics and comics into films from 1930 to 1960. This review argues that 'Movie Comics' provides a useful and finely-textured cultural history of that phenomenon, which help contextualize scholarly studies of contemporary adaptations and transmedia constructions.

  7. Coming to Life: A Review of Movie Comics: Page to Screen/Screen to Page

    Directory of Open Access Journals (Sweden)

    Nicolas Labarre

    2017-03-01

    Full Text Available This book review provides an overview of 'Movie Comics: Page to Screen/Screen to Page' by Blair Davis (Rutgers University Press, 2017 a book which examines the reciprocal adaptations of film into comics and comics into films from 1930 to 1960. This review argues that 'Movie Comics' provides a useful and finely-textured cultural history of that phenomenon, which help contextualize scholarly studies of contemporary adaptations and transmedia constructions.

  8. Intellectual Video Filming

    DEFF Research Database (Denmark)

    Juel, Henrik

    in favour of worthy causes. However, it is also very rewarding to draw on the creativity, enthusiasm and rapidly improving technical skills of young students, and to guide them to use video equipment themselves for documentary, for philosophical film essays and intellectual debate. In the digital era......Like everyone else university students of the humanities are quite used to watching Hollywood productions and professional TV. It requires some didactic effort to redirect their eyes and ears away from the conventional mainstream style and on to new and challenging ways of using the film media...

  9. Teaching Chinese Film in an Advanced Language Class

    OpenAIRE

    Chen, Luying

    2011-01-01

    Instructors often face a dilemma when using film in language classes. While film is appealing for the rich cultural and linguistic information it offers, finding the balance between teaching content and building language skills can present significant challenges for an instructor. Common approaches to using film in courses taught in English, such as screening one film a week, reading critical essays about the films, and class discussions and lectures, seldom offer the same benefits in a forei...

  10. Film holder for radiographing tubing

    International Nuclear Information System (INIS)

    Davis, E.V.; Foster, B.E.

    1976-01-01

    A film cassette is described which may be easily placed about tubing or piping and readily held in place while radiographic inspection is performed. A pair of precurved light-impervious semi-rigid plastic sheets, hinged at one edge, enclose sheet film together with any metallic foils or screens. Other edges are made light-tight with removable caps, and the entire unit is held securely about the object to be radiographed with a releasable fastener such as a strip of Velcro

  11. Film holder for radiographing tubing

    Science.gov (United States)

    Davis, Earl V.; Foster, Billy E.

    1976-01-01

    A film cassette is provided which may be easily placed about tubing or piping and readily held in place while radiographic inspection is performed. A pair of precurved light-impervious semi-rigid plastic sheets, hinged at one edge, enclose sheet film together with any metallic foils or screens. Other edges are made light-tight with removable caps, and the entire unit is held securely about the object to be radiographed with a releasable fastener such as a strip of Velcro.

  12. Strategic interaction and conventions

    Directory of Open Access Journals (Sweden)

    Espinosa, María Paz

    2012-03-01

    Full Text Available The scope of the paper is to review the literature that employs coordination games to study social norms and conventions from the viewpoint of game theory and cognitive psychology. We claim that those two alternative approaches are in fact complementary, as they provide different insights to explain how people converge to a unique system of self-fulfilling expectations in presence of multiple, equally viable, conventions. While game theory explains the emergence of conventions relying on efficiency and risk considerations, the psychological view is more concerned with frame and labeling effects. The interaction between these alternative (and, sometimes, competing effects leads to the result that coordination failures may well occur and, even when coordination takes place, there is no guarantee that the convention eventually established will be the most efficient.

    El objetivo de este artículo es presentar la literatura que emplea los juegos de coordinación para el estudio de normas y convenciones sociales, que se han analizado tanto desde el punto de vista de la teoría de juegos como de la psicología cognitiva. Argumentamos en este trabajo que estos dos enfoques alternativos son en realidad complementarios, dado que ambos contribuyen al entendimiento de los procesos mediante los cuales las personas llegan a coordinarse en un único sistema de expectativas autorrealizadas, en presencia de múltiples convenciones todas ellas igualmente viables. Mientras que la teoría de juegos explica la aparición de convenciones basándose en argumentos de eficiencia y comportamientos frente al riesgo, el enfoque de la psicología cognitiva utiliza en mayor medida consideraciones referidas al entorno y naturaleza de las decisiones. La interacción entre estos efectos diferentes (y en ocasiones, rivales desemboca con frecuencia en fallos de coordinación y, aun cuando la coordinación se produce, no hay garantía de que la convención en vigor sea la m

  13. Conventional RF system design

    International Nuclear Information System (INIS)

    Puglisi, M.

    1994-01-01

    The design of a conventional RF system is always complex and must fit the needs of the particular machine for which it is planned. It follows that many different design criteria should be considered and analyzed, thus exceeding the narrow limits of a lecture. For this reason only the fundamental components of an RF system, including the generators, are considered in this short seminar. The most common formulas are simply presented in the text, while their derivations are shown in the appendices to facilitate, if desired, a more advanced level of understanding. (orig.)

  14. Conventional magnets. Pt. 1

    International Nuclear Information System (INIS)

    Marks, N.

    1994-01-01

    The design and construction of conventional, steel-cored, direct-current magnets are discussed. Laplace's equation and the associated cylindrical harmonic solutions in two dimensions are established. The equations are used to define the ideal pole shapes and required excitation for dipole, quadrupole and sextupole magnets. Standard magnet geometries are then considered and criteria determining the coil design are presented. The use of codes for predicting flux density distributions and the iterative techniques used for pole face design are then discussed. This includes a description of the use of two-dimensional codes to generate suitable magnet end geometries. Finally, standard constructional techniques for cores and coils are described. (orig.)

  15. Karakteristik Desain Poster Film Animasi Amerika Serikat

    Directory of Open Access Journals (Sweden)

    Aniendya Christianna

    2010-01-01

    Full Text Available An animated film will end in vain no matter how well it is without the support of media to give buzz to the message of the film. One of the most important advertising media in promoting an animated film is the poster. Because the animation movie poster is the leading medium which deals directly with the target audience in delivering information about the film before the screening of the film takes place. So visualization of the poster that includes the composition of verbal and non verbal language deserves more attention in its design.

  16. Lunar Dust Mitigation Screens

    Science.gov (United States)

    Knutson, Shawn; Holloway, Nancy

    being developed in a collaborative effort between Langley Research Center and Kennedy Space Center. The screens typically consist of spiral shaped conductive traces patterned on high dielectric substrates (i.e. glass, quartz, polyimide film, etc.). Two broad categories of substrate materials are being investigated for the screens. One category consists of transparent substrates (i.e. glass, quartz, sapphire, etc.), and the other non-transparent sub-strates (Kapton, polyimide films, metals, etc.). The transparent screens utilize patterns made from indium tin oxide (ITO), a transparent conductive material, on clear substrates while the non-transparent screens use copper patterns on a transluscent or opaque substrates. Further, the screen is coated with a high dielectric polyimide cover layer to protect the screen pattern. One promising cover layer material that is currently being investigated is Langley Research Center-Soluble Imide (LaRC-SI), a NASA LaRC developed polyimide. Lastly, a top-coat of hard, inorganic material is evaporated onto the cover layer for protection from scratches due to abrasive nature of the dust. Of note, several top-coat materials are under investigation and include: aluminum oxide, silicon dioxide, titanium oxide, yttrium oxide, zirconium oxide, and zinc sulfide. The electrostatic dust mitigation screens function when a high voltage (700V or greater) is applied to the screen electrodes, thus creating an electromagnetic wave across the surface of the screen that repels the dust. Lunar dust typically contains a high positive charge; therefore, the screens are charged with a higher positive charge that effectively repels dust from the surface (i.e. like charges repel, unlike charges attract). It is anticipated that full development and maturation of this technology will enable humans to sustain a long term presence on the moon, and other planets where dust may have negative implications.

  17. A screen-printed Ce 0.8Sm 0.2O 1.9 film solid oxide fuel cell with a Ba 0.5Sr 0.5Co 0.8Fe 0.2O 3- δ cathode

    Science.gov (United States)

    Zhang, Yaohui; Huang, Xiqiang; Lu, Zhe; Liu, Zhiguo; Ge, Xiaodong; Xu, Jiahuan; Xin, Xianshuang; Sha, Xueqing; Su, Wenhui

    Screen-printing technology was developed to fabricate Ce 0.8Sm 0.2O 1.9 (SDC) electrolyte films onto porous NiO-SDC green anode substrates. After sintering at 1400 °C for 4 h, a gas-tight SDC film with a thickness of 12 μm was obtained. A novel cathode material of Ba 0.5Sr 0.5Co 0.8Fe 0.2O 3- δ was subsequently applied onto the sintered SDC electrolyte film also by screen-printing and sintered at 970 °C for 3 h to get a single cell. A fuel cell of Ni-SDC/SDC (12 μm)/Ba 0.5Sr 0.5Co 0.8Fe 0.2O 3- δ provides the maximum power densities of 1280, 1080, 670, 370, 180 and 73 mW cm -2 at 650, 600, 555, 505, 455 and 405 °C, respectively, using hydrogen as fuel and stationary air as oxidant. When dry methane was used as fuel, the maximum power densities are 876, 568, 346 and 114 mW cm -2 at 650, 600, 555 and 505 °C, respectively. The present fuel cell shows excellent performance at lowered temperatures.

  18. Screen dealing

    International Nuclear Information System (INIS)

    Barlow, J.W.

    1991-01-01

    The screen dealing system provides a facility whereby buyers and sellers of spot thermal coal can make bids and offers via the medium of the Reuters screen. A sale results when a market participant notifies his acceptance of a price to a central dealing desk. Use of the system is available to all genuine participants in the coal trade. This paper reports that it provides a focus for information and for the visible making of coal prices. For years screen trading has been used successfully to trade other commodities. At last coal is being traded electronically. It makes sense. It works. Users like it

  19. Change of characteristic curves using light emission spectrum of the intensifying screens

    International Nuclear Information System (INIS)

    Yoon, Chul Ho; Kang, Hong Seok; Lee, In Ja; Huh, Joon

    1990-01-01

    This report is study about difference of H-D curve in regular film and ortho type film, and obtained results as follows: 1. In the blue-color emission intensifying screen, ortho type films and in the green-color emission intensifying screens, regular type are decreased in their gradient. 2. When joint use of regular type film and ortho type film, the gradient difference not seen in blue color screen. 3. The gradient difference seen clearly in G4, KM screens (green color emission intensifying). Especially, in part of high film density, the gradient difference are great. So we have to right use of screen and film because not matched used of there the sensitivity and gradient are decrease

  20. Pennsylvania's experience in mass screening

    International Nuclear Information System (INIS)

    Gerusky, T.M.

    1975-01-01

    A policy statement issued in 1972 by the Assistant Secretary for Health and Scientific Affairs of the Department of Health, Education, and Welfare recommended that community chest x-ray surveys should not be used as a screening procedure for the detection of cardiopulmonary disorders and that when chest x-ray screening programs are justified for selected population groups, the full size photograph, rather than the miniature film, is preferred. A survey conducted in 1974--75 revealed that chest x rays were required for prisoners, prison employees, school employees, food handlers, and students who wished to participate in sports. Meetings were held with medical associations in the hope of stopping the local mass-screening operations. Of 27 groups in Pennsylvania involved in tuberculosis screening, 12 groups refused or were unwilling to phase out their photofluorographic procedures. The problem will be resolved by regulation

  1. Film-based dual energy radiography

    International Nuclear Information System (INIS)

    Sandrik, J. M.; Pelc, N. J.

    1985-01-01

    X-ray energy-difference images are obtained simultaneously by exposing a body to a broad energy spectrum X-ray beam while a radiographic film package is disposed between front and rear X-ray intensifying screens. The film package has two superimposed films with a light-opaque sheet between them. The front screen, on which the polyenergetic image beam emerging from the body is incident, is excited to luminescence by X-ray photons predominantly in one energy band and the rear screen is excited predominantly by photons in another band. The light opaque sheet preferably contains X-ray filter material for additional filtering of photons to increase the fraction of protons at said other band to which the rear screen is sensitive. A shadowgraph of a marker is formed on the film emulsions during X-ray exposure to aid in matching congruent picture elements on each film when the developed films are being read out to obtain signals corresponding to their intensities. Notches in the edges of the films and sheet serve as a code for indicating the type of screens with which the package can be used

  2. Airport Screening

    Science.gov (United States)

    Health Physics Society Specialists in Radiation Safety Airport Screening Fact Sheet Adopted: May 2011 Photo courtesy of Dan ... a safe level. An American National Standards Institute/Health Physics Society industry standard states that the maxi- mum ...

  3. Hypertension screening

    Science.gov (United States)

    Foulke, J. M.

    1975-01-01

    An attempt was made to measure the response to an announcement of hypertension screening at the Goddard Space Center, to compare the results to those of previous statistics. Education and patient awareness of the problem were stressed.

  4. Carrier Screening

    Science.gov (United States)

    ... How accurate is carrier screening? No test is perfect. In a small number of cases, test results ... in which an egg is removed from a woman’s ovary, fertilized in a laboratory with the man’s ...

  5. Advertising media strategies in the film industry

    OpenAIRE

    Elliott, Caroline; Simmons, Robert

    2011-01-01

    The primary aim of this article is to estimate the multiple determinants of film advertising expenditures in four important media, namely television, press, outdoor and radio, in the UK. First, television advertising, the leading film advertising medium, is examined as part of a system of equations, capturing the interdependences between advertising, the number of screens on which films are initially shown and box office revenues. Then a reduced form model is put forward to reveal the determi...

  6. Thin films

    International Nuclear Information System (INIS)

    Strongin, M.; Miller, D.L.

    1976-01-01

    This article reviews the phenomena that occur in films from the point of view of a solid state physicist. Films form the basis for many established and developing technologies. Metal layers have always been important for optical coatings and as protective coatings. In the most sophisticated cases, films and their interaction on silicon surfaces form the basis of modern electronic technology. Films of silicon, GaAs and composites of these materials promise to lead to practical photovoltaic devices

  7. Phytochemical Screening, Antibacterial and Toxicological Activities ...

    African Journals Online (AJOL)

    The phytochemical screening, antibacterial and toxicological activities of extracts of the stem bark of Acacia senegal were investigated. The phytochemical analyses according to standard screening tests using conventional protocols revealed the presence of tannins, saponins and sterols in the stem bark of the plant.

  8. Nuclear films

    International Nuclear Information System (INIS)

    Malone, Peter.

    1985-01-01

    This booklet is a resource for the study of feature films that highlight the theme of nuclear war. It provides basic credits and brief indication of the theme, treatment, quality and particular notable aspects; and a series of questions raised by the film. Seventy feature films and thirty documentaries are examined

  9. Icons and Emoticons: Screen Wars

    OpenAIRE

    Duerfahrd, Lance

    2015-01-01

    The cinema is being upstaged by a device paradoxically meant (in part) to transmit it: the iPhone. How do films change, how is their impact altered, when viewed on these devices? What aspects of the movie screen (and subsequently our movie experience) are lost or threatened when they are displaced by this new technological format? This is not an abstract war: it is going on (in the dark) every time we attend a screening. My paper will explore what is at stake in our decision to illuminate our...

  10. UTILIZATION OF CINEMATOGRAPHIC ELEMENTS FOR PRODUCTION OF EDUCATIONAL FILMS

    Directory of Open Access Journals (Sweden)

    Ozcan Demir

    2017-01-01

    Full Text Available Educational films are productions aiming to inform target audience about designated issues. Educational films are distributed via television, cinema, computers (CD, DVD and Internet environment with technological developments. Films are produced by means of digital technologies. Despite the means for film presentation and distribution go through a change, the cinematography concept systemizing artistic and technical principles of film production has been continuing to exist as a valid assessment criterion for all films. Cinematographic agreements, which encompass precise organization of images and sounds for films, ensure conveying the message of productions. In this study, conventions that could be affective on preparation of educational films at the utilization environments of cinematographic principles and on sustaining interest on the productions have been scrutinized, and the usage purposes of these conventions in educational films have been discussed.

  11. X-ray film cassette and method of making

    International Nuclear Information System (INIS)

    1980-01-01

    An x-ray film cassette which is capable of providing forces on the film that vary across the surface of the cassette is described. Methods of manufacture are discussed. The system is of particular use when large area films are used in conjunction with intensifying screens. (U.K.)

  12. Facebook Used in a German Film Project

    Science.gov (United States)

    Leier, Vera

    2011-01-01

    Looking for a way to make German language study more relevant and to step out of the conventional classroom setting, I introduced Facebook (FB) as a learning platform to my intermediate German students at the University of Canterbury, New Zealand. The students took part in a film competition. A FB group was created and the films were uploaded. The…

  13. ESD and the Rio Conventions

    Science.gov (United States)

    Sarabhai, Kartikeya V.; Ravindranath, Shailaja; Schwarz, Rixa; Vyas, Purvi

    2012-01-01

    Chapter 36 of Agenda 21, a key document of the 1992 Earth Summit, emphasised reorienting education towards sustainable development. While two of the Rio conventions, the Convention on Biological Diversity (CBD) and the United Nations Framework Convention on Climate Change (UNFCCC), developed communication, education and public awareness (CEPA)…

  14. Metal ion implantation: Conventional versus immersion

    International Nuclear Information System (INIS)

    Brown, I.G.; Anders, A.; Anders, S.; Dickinson, M.R.; MacGill, R.A.

    1994-01-01

    Vacuum-arc-produced metal plasma can be used as the ion feedstock material in an ion source for doing conventional metal ion implantation, or as the immersing plasma for doing plasma immersion ion implantation. The basic plasma production method is the same in both cases; it is simple and efficient and can be used with a wide range of metals. Vacuum arc ion sources of different kinds have been developed by the authors and others and their suitability as a metal ion implantation tool has been well established. Metal plasma immersion surface processing is an emerging tool whose characteristics and applications are the subject of present research. There are a number of differences between the two techniques, both in the procedures used and in the modified surfaces created. For example, the condensibility of metal plasma results in thin film formation and subsequent energetic implantation is thus done through the deposited layer; in the usual scenario, this recoil implantation and the intermixing it produces is a feature of metal plasma immersion but not of conventional energetic ion implantation. Metal plasma immersion is more suited (but not limited) to higher doses (>10 17 cm -2 ) and lower energies (E i < tens of keV) than the usual ranges of conventional metal ion implantation. These and other differences provide these vacuum-arc-based surface modification tools with a versatility that enhances the overall technological attractiveness of both

  15. Multi-component Ce doped (Gd,Y,La,Lu)3(AlGaSc)5O12 garnets – A new story in the development of scintillating single crystalline film screens

    International Nuclear Information System (INIS)

    Zorenko, Yu.; Gorbenko, V.; Savchyn, V.; Zorenko, T.; Fedorov, A.; Wrzesinski, H.; Vasylkiv, Ya.

    2013-01-01

    The paper is dedicated to development of the scintillators based on single crystalline films of Ce doped (GdLaYLu) 3 (AlGaSc) 5 O 12 multi-component garnets onto Gd 3 Ga 5 O 12 substrates using the liquid phase epitaxy method. -- Highlights: •Growth of Ce doped (GdYLaLu) 3 (AlGaSc) 5 O 12 garnets films by LPE method. •Luminescent and scintillation properties of Ce doped (GdYLaLu) 3 (AlGaSc) 5 O 12 films. •Influence of Pb 2+ flux related impurity on the light yield of Ce 3+ emission

  16. Luminescent screens

    International Nuclear Information System (INIS)

    Lu, C.-I.

    1982-01-01

    Luminescent screens which are useful for such purposes as intensifying screens for radiographs are comprised of a support bearing a layer of finely divided particles of a phosphor dispersed in a cross-linked polymeric matrix formed by heat-curing of a coating composition comprising an unsaturated cross-linkable polymer, a polymerizable acrylic monomer, a thermoplastic polyurethane elastomer, and a heat-activatable polymerization initiator. The phosphor layer includes voids formed by evaporation of an evaporable component which is present in the coating composition from which such layer is formed. (author)

  17. Greening the Screen: An Environmental Challenge

    OpenAIRE

    Ekin Gündüz Özdemirci

    2016-01-01

    Environmental themes and representations on screen are examined as a part of environmental social studies and can be considered a way of creating awareness of environmental issues. However, how often do we consider the environmental impact of a film or television shoot as an industrial process? In this article, I examine the sustainability practices in the motion picture industry and challenges to that by focusing on the British film and television industry as a case study. Using the intervie...

  18. Alcohol Use Screening

    Science.gov (United States)

    ... Depression Screening Substance Abuse Screening Alcohol Use Screening Alcohol Use Screening (AUDIT-C) - Instructions The following questions ... this tool, there is also text-only version . Alcohol Use Screening (AUDIT-C) - Manual Instructions The following ...

  19. Evaluation and mitigation of potential errors in radiochromic film dosimetry due to film curvature at scanning.

    Science.gov (United States)

    Palmer, Antony L; Bradley, David A; Nisbet, Andrew

    2015-03-08

    This work considers a previously overlooked uncertainty present in film dosimetry which results from moderate curvature of films during the scanning process. Small film samples are particularly susceptible to film curling which may be undetected or deemed insignificant. In this study, we consider test cases with controlled induced curvature of film and with film raised horizontally above the scanner plate. We also evaluate the difference in scans of a film irradiated with a typical brachytherapy dose distribution with the film naturally curved and with the film held flat on the scanner. Typical naturally occurring curvature of film at scanning, giving rise to a maximum height 1 to 2 mm above the scan plane, may introduce dose errors of 1% to 4%, and considerably reduce gamma evaluation passing rates when comparing film-measured doses with treatment planning system-calculated dose distributions, a common application of film dosimetry in radiotherapy. The use of a triple-channel dosimetry algorithm appeared to mitigate the error due to film curvature compared to conventional single-channel film dosimetry. The change in pixel value and calibrated reported dose with film curling or height above the scanner plate may be due to variations in illumination characteristics, optical disturbances, or a Callier-type effect. There is a clear requirement for physically flat films at scanning to avoid the introduction of a substantial error source in film dosimetry. Particularly for small film samples, a compression glass plate above the film is recommended to ensure flat-film scanning. This effect has been overlooked to date in the literature.

  20. Hearing Screening

    Science.gov (United States)

    Johnson-Curiskis, Nanette

    2012-01-01

    Hearing levels are threatened by modern life--headsets for music, rock concerts, traffic noises, etc. It is crucial we know our hearing levels so that we can draw attention to potential problems. This exercise requires that students receive a hearing screening for their benefit as well as for making the connection of hearing to listening.

  1. Vision Screening

    Science.gov (United States)

    ... an efficient and cost-effective method to identify children with visual impairment or eye conditions that are likely to lead ... main goal of vision screening is to identify children who have or are at ... visual impairment unless treated in early childhood. Other problems that ...

  2. Regulated and Liberated Bodies of Schoolgirls in a Finnish Short Film from the 1950s

    Science.gov (United States)

    Nieminen, Marjo

    2018-01-01

    This article focuses on the bodies of schoolgirls as visualised and represented in a short film of Finnish secondary schools for girls in the 1950s. The film, "Oma tyttökouluni" ("My Own Girls' School") was released in 1957 and was screened in cinemas in advance of feature films. Although the short film was made in a…

  3. Analyzing the Hidden Curriculum of Screen Media Advertising

    Science.gov (United States)

    Mason, Lance E.

    2015-01-01

    This media literacy article introduces a questioning framework for analyzing screen media with students and provides an example analysis of two contemporary commercials. Investigating screen conventions can help students understand the persuasive functions of commercials, as well as how the unique sensory experience of screen viewing affects how…

  4. Multi-layer x-ray screens

    International Nuclear Information System (INIS)

    Rabatin, J.G.

    1984-01-01

    Rare earth oxyhalide phosphors activated with thulium ion are employed in X-ray intensifying screens having modified ultraviolet emission characteristics which reduce crossover effects without significant reduction in film speed and further increases screen brightness. Relatively low concentration levels of the thulium activator ion have been found to shift the ultraviolet emission of said phosphor when excited by X-rays to lower wavelengths in both the ultraviolet and near-ultraviolet spectral regions

  5. Application of the Aarhus Convention

    Directory of Open Access Journals (Sweden)

    Tubić Bojan

    2011-01-01

    Full Text Available Convention on access to information, public participation in decision-making and access to justice in environmental matters (Aarhus Convention has been adopted in 1998 and entered into force three years later. It envisages three elements for strengthening democratic procedures in decision-making: access to information, public participation and access to justice. At the first meeting of the Member States the Aarhus Convention Compliance Committee was founded. The European Union is a party of the Convention and it has implemented the provisions in its legal order. After entering into force of the Convention, several Directives that regulate these issues in the EU have been enacted. Republic of Serbia has ratified the Convention in 2009 and it is currently in the process of its implementation by involving private subjects in decision-making on environmental issues.

  6. Film processing

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    The processing was made not only to show what are in the film but also to produce radiograph with high quality where the information gathered really presented level of the quality of the object inspected. Besides that, good procedure will make the film with good quality can keep the film in long time for reference. Here, more detailed on how the dark room functioned and its design. So, the good procedure while processed the film will be discussed detailed in this chapter from entering the dark room to exit from there.

  7. Demens Film

    DEFF Research Database (Denmark)

    Jensen, Anders Møller

    2012-01-01

    Vi vil skabe film til mennesker med demens – ikke film om demens sygdommen eller beretninger om livet og hverdagen med en kronisk lidelse. Filmene skal medvirke til at frembringe en behagelig stemning omkring og hos mennesker med demens, så hverdagen bliver så tryg som mulig. Filmene skal samtidig...... var at afgrænse og prioritere projektet, samt komme med anbefalinger omkring hvad der er vigtigt, i forbindelse med produktion af film målrettet mennesker med demens. Resultat af ekspertgruppen sammenfattes i denne rapport. Projektet gennemføres som et samarbejde mellem Retrospect Film...

  8. Understanding the conventional arms trade

    Science.gov (United States)

    Stohl, Rachel

    2017-11-01

    The global conventional arms trade is worth tens of billions of dollars every year and is engaged in by every country in the world. Yet, it is often difficult to control the legal trade in conventional arms and there is a thriving illicit market, willing to arm unscrupulous regimes and nefarious non-state actors. This chapter examines the international conventional arms trade, the range of tools that have been used to control it, and challenges to these international regimes.

  9. New intensifying screens in clinical radiology. Pt. 2

    International Nuclear Information System (INIS)

    Freyschmidt, J.; Saure, D.; Hagemann, G.

    1976-01-01

    A clinically applicable procedure for testing new intensifying rare earth screens, as well as the special Siemens' screen is described. The results are related to universal screeens. The film-screen combination α 4XD (gadolinium oxysulphide with normal, green sensitive film) results in a reduction of radiation dose to half with detail comparable with universal screens. The Siemens' special screen has similar advantages. Screens with a higher intensification factor and reduction of the mAs to one sixth results in loss of detail. This does not necessarily reduce their clinical use if they are used for appropriate purposes. The results of this clinically orientated technique agreed well with physically objective methods using lead grids. The advantages of the new screens are discussed in terms of their practical application. (orig.) [de

  10. Comparison of Conventional and Semi-Conventional Management ...

    African Journals Online (AJOL)

    Comparison of Conventional and Semi-Conventional Management Systems on the Performance and Carcass Yield of Broiler Chickens. ... TO AFRICAN RESEARCH. AFRICAN JOURNALS ONLINE (AJOL) · Journals · Advanced Search · USING AJOL · RESOURCES ... Journal Home > Vol 20, No 1 (2018) >. Log in or ...

  11. Taking place, screening place

    DEFF Research Database (Denmark)

    Hansen, Kim Toft; Waade, Anne Marit

    2019-01-01

    We introduce location studies as a new empirical approach to screen studies. Location studies represent an interdisciplinary perspective, including media, aesthetics and geography, and reflect a growing interest in places in a global media and consumption culture. The chapter analyses two recent......) with one being traditional and the other being commercial; both dramas include discussions of localities and social heritage, and both use local sports as a common metaphor for social cohesion; and both series have been partly funded by a local film Danish commissioner. However, The Legacy is shot...... to a large extent in studios, while Norskov is shot entirely on location. The study is based on interviews with producers, broadcasters, location scouts, production designers and writers, as well as quantitative and qualitative textual analyses of television drama series, the geographical places, and related...

  12. Boleslas Matuszewski: Pioneer of medical film-making

    Directory of Open Access Journals (Sweden)

    Matanović Dragana

    2005-01-01

    Full Text Available Boleslas Matuszewski, born in 1856, was a pioneer in medical film-making. He worked simultaneously on improving his movie camera, film-making, collecting film documentation, and the idea of establishing an archive of medical films. Although his first attempts at filming and showing surgical operations didn't gain widespread approval, he was not discouraged, and succeeded in garnering support from a number of French doctors, who realized the importance of his ideas, not only in filming and forming medical film documentation, but also in the use of film for educative purposes. His visionary ideas gained acceptance when Dr. Doyen, on the occasion of the 66th Convention of the British Medical Society, in 1898, used film material as part of his lecture. Shortly afterwards, the Medical Academy took steps to show certain operative techniques, which represented both the confirmation and fruition of Matuszewski's ideas about filmmaking and the establishment of an archive of medical films.

  13. Two against one - a case for single-sided films

    International Nuclear Information System (INIS)

    Dixon, L.

    1979-01-01

    The disadvantages of double-sided X-ray film include parallax between the double images where the film is angled to the central ray, and a cross-over effect where light from the front screen affects the back emulsion and vice versa. An investigation of the percentage of the total film density due to cross-over showed the effect varied from 28% to 47%, increasing with total density and faster screens. Kilovoltage had little influence on the effect. A single emulsion film with one screen gave an appreciable increase in radiographic sharpness and definition but required an increase by about 2.5 times in the exposure required. A very fast screen overcame this effect without comparable loss of detail. The use of single emulsion films should also reduce the thickness of cut and therefore improve sharpness in tomography. (UK)

  14. Reading through Films

    Directory of Open Access Journals (Sweden)

    Madhavi Gayathri Raman

    2016-02-01

    Full Text Available This paper captures the design of a comprehensive curriculum incorporating the four skills based exclusively on the use of parallel audio-visual and written texts. We discuss the use of authentic materials to teach English to Indian undergraduates aged 18 to 20 years. Specifically, we talk about the use of parallel reading (screen-play and audio-visual texts (Shawshank Redemption, and Life is Beautiful, A Few Good Men and Lion King drawn from popular culture in the classroom as an effective teaching medium. Students were gradually introduced to films based on novels with extracts from the original texts (Schindler’s List, Beautiful Mind for extended reading and writing practice. We found that students began to pay more attention to aspects such as pronunciation, intonational variations, discourse markers and vocabulary items (phrasal verbs, synonyms, homophones, and puns. Keywords: Reading, films, popular culture, ESL classroom, language skills

  15. Censoring and Selling Film Noir

    Directory of Open Access Journals (Sweden)

    Sheri Chinen Biesen

    2015-05-01

    Full Text Available Film noir is known for its duplicity. Industry censors considered 1940s noir cinema provocative, salacious and ‘sordid.’ Hollywood studios walked a fine line between appearing to comply with Hays office Production Code censorship while simultaneously pushing the envelope of its moral constraints, then hyping and sensationalizing censorable sex, violence and hard-hitting themes to sell noir films to the public. In fact, studios capitalized on the racy explicit nature of noir pictures in publicity contradicting assurances of censorial compliance. For instance, censor Joseph Breen was “shocked” when MGM purchased James Cain’s The Postman Always Rings Twice. It was banned for a decade. Yet, ten years later as filmmakers adapted hardboiled fiction, Breen assured religious groups it would “not be offensive.” Yet, it was promoted as “torrid,” “too hot to handle” with Lana Turner in a bathing suit finding “Love at Laguna Beach” with hunky John Garfield who clamored, “You must be a she-devil,” suggesting far more sex, skin and “savage boldness” than is shown in the film. Film noir responded to Production Code censorship and other regulatory factors, including Office of War Information Bureau of Motion Pictures restrictions on Hollywood screen depictions of the domestic American home front (or overseas combat front, and Office of Censorship strictures such as a wartime ban on screen gangsters as ‘un-American’ for propaganda purposes in World War II-era noir films centering on criminals. These multiple censorship entities often collided. This regulatory climate catalyzed the development of film noir, a dark cycle of shadowy 1940s-50s crime films that boomed by World War II and evolved over the postwar era. I will investigate extensive primary archival research—including scripts, memos from industry censors, writers, directors, producers, and publicity records—to compare how film noir was censored and sold.

  16. Vision Screening

    Science.gov (United States)

    1993-01-01

    The Visi Screen OSS-C, marketed by Vision Research Corporation, incorporates image processing technology originally developed by Marshall Space Flight Center. Its advantage in eye screening is speed. Because it requires no response from a subject, it can be used to detect eye problems in very young children. An electronic flash from a 35 millimeter camera sends light into a child's eyes, which is reflected back to the camera lens. The photorefractor then analyzes the retinal reflexes generated and produces an image of the child's eyes, which enables a trained observer to identify any defects. The device is used by pediatricians, day care centers and civic organizations that concentrate on children with special needs.

  17. Quasi-film commercials. Analysis of selected car manufacturer campaigns

    OpenAIRE

    Barczyk-Sitkowska, Agnieszka

    2017-01-01

    When seeking original forms of expression, contemporary commercials often reach for the achievements of film making. That is reflected in references to the conventions of certain film genres, and the references to particular films. The goal of the article was to present selected examples of the relationships between commercials and film, which can be found in car manufacturer advertising campaigns (Toyota, BMW, and Mercedes-Benz). The analysis of the gathered study material enabled me to iden...

  18. Reflection from a flat dielectric film with negative refractive index

    OpenAIRE

    Hillion, Pierre

    2007-01-01

    We analyse the reflection of a TM electromagnetic field first on a flat dielectric film and second on a Veselago film with negative refractive index, both films being deposited on a metallic substrat acting as a mirror. An incident harmonic plane wave generates inside a conventional dielectric film a refracted propagating wave and an evanescent wave that does not contribute to reflection on the metallic substrat so that part of the information conveyed by the incident field is lost. At the op...

  19. Short-film Festival at the Globe

    CERN Multimedia

    2007-01-01

    Get out your diaries and prepare to be star-struck as the Globe of Science and Innovation meets the silver screen! The CERN "Open Your Eyes Films" film-making club is organising a festival of short films entitled CinéGlobe from Thursday 8 to Saturday 10 November. On the Thursday and Friday, you’ll be able to watch 47 short films free of charge in the Globe of Science and Innovation at various times of the day. The short films to be screened come from 21 different countries and have been selected from among 1400 entrees! All film genres will be represented : comedy, drama, animation, documentaries, experimental films, etc. Members of the public will even be able to vote for their favourite film: the audience’s favourite will be awarded a "Coup de coeur" award. An awards ceremony to honour the films that have received most votes will be held on Friday evening in the Globe of Science and Innovation. The Golden CinéGlobe for bes...

  20. Interface Screenings

    DEFF Research Database (Denmark)

    Thomsen, Bodil Marie Stavning

    2015-01-01

    In Wim Wenders' film Until the End of the World (1991), three different diagrams for the visual integration of bodies are presented: 1) GPS tracking and mapping in a landscape, 2) video recordings layered with the memory perception of these recordings, and 3) data-created images from dreams...... and memories. From a transvisual perspective, the question is whether or not these (by now realized) diagrammatic modes involving the body in ubiquitous global media can be analysed in terms of the affects and events created in concrete interfaces. The examples used are filmic as felt sensations...

  1. thin films

    Indian Academy of Sciences (India)

    microscopy (SEM) studies, respectively. The Fourier transform ... Thin films; chemical synthesis; hydrous tin oxide; FTIR; electrical properties. 1. Introduction ... dehydrogenation of organic compounds (Hattori et al 1987). .... SEM images of (a) bare stainless steel and (b) SnO2:H2O thin film on stainless steel substrate at a ...

  2. Into films

    DEFF Research Database (Denmark)

    Tan, Ed S.; Doicaru, Miruna M.; Hakemulder, Frank

    2017-01-01

    Most film viewers know the experience of being deeply absorbed in the story of a popular film. It seems that at such moments they lose awareness of watching a movie. And yet it is highly unlikely that they completely ignore the fact that they watch a narrative and technological construction. Perh...

  3. Towards a Theory of Convention

    DEFF Research Database (Denmark)

    Hansen, Pelle Guldborg

    2006-01-01

    Some thirty years ago Lewis published his Convention: A philosophical Study (Lewis 1969). Besides exciting the logical community by providing the seminal analysis work on common knowledge, it also laid the foundations for the formal approach to the study of social conventions by means of game the...

  4. Evaluation of average glandular dose in digital and conventional systems of the mammography; Avaliacao da dose glandular media em sistemas digitais e convencionais de mamografia

    Energy Technology Data Exchange (ETDEWEB)

    Xavier, Aline C.S.; Barros, Vinicius S.M.; Khoury, Hellen J., E-mail: alinecx90@gmail.com, E-mail: vsmdbarros@gmail.com, E-mail: hjkhoury@gmail.com [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear; Mello, Francisca A. de, E-mail: francissamello@yahoo.com.br [Hospital das Clinicas do Recife (HCR/UFPE), PE (Brazil)

    2014-07-01

    Mammography is currently the most effective method of diagnosis and detection of breast pathologies. The main interest in this kid of exam comes from the high incidence rate of breast cancer and necessity of high quality images for accurate diagnosis. Digital mammography systems have several advantages compared to conventional systems, however the use of digital imaging systems is not always integrated to an image acquisition protocol. Therefore, it is questionable if digital systems truly reduce the dose received by the patient, because many times is introduced in the clinics without optimization of the image acquisition protocols. The aim of this study is to estimate the value of incident air Kerma and average glandular dose (AGD) in patients undergoing conventional and digital mammography systems in Recife. This study was conducted with 650 patients in three hospitals. The value of incident air Kerma was estimated from the measurement of the yield of equipment and irradiation parameters used for each patient. From these results and using the methodology proposed by Dance et al. the value of the average glandular dose was calculated. The results obtained show that the lowest value of AGD was found with conventional screen-film system, indicating that the parameters for image acquisition with digital systems are not optimized. It was also observed that the institutions with digital systems use lower breast compression values than the conventional. (author)

  5. A comparative study of CaWO4 and rare earth intensifying screens

    International Nuclear Information System (INIS)

    Ambiger, T.Y.; Ayappan, P.

    1978-01-01

    Three brands of commercially available calcium tungstate intensifying screens and a brand of rare earth screen emitting blue light have been used with two types of fast medical x-ray films, one imported and the other indigenous in various film-screen combinations and their sensitometric properties have been determined and compared. The rare earth screen has been found to be about 3 to 4 times faster than the tungstate screens without reduction in contrast. This indicates that the use of rare earth screen in medical radiography will help to reduce the patient dose by the same factor. (M.G.B.)

  6. Revision of the Paris Convention and the Brussels Supplementary Convention

    International Nuclear Information System (INIS)

    Busekist, Otto von.

    1977-01-01

    The Paris Convention and the Brussels Supplementary Convention have in substance remained unchanged since their adoption in 1960 and 1963, respectively. During that period, nuclear industry and technology have developed considerably while the financial and monetary bases of the Conventions have been shattered. The amounts of liability and compensation have been eroded by inflation, and the gold-based unit of account in which these amounts are expressed has lost its original meaning after the abolition of the official gold price. The question of revising the Conventions, in particular of raising those amounts and of replacing the unit of account, is therefore being studied by the Group of Governmental Experts on Third party Liability in the Field of Nuclear Energy of the OECD Nuclear Energy Agency. (auth.) [fr

  7. The nuclear liability conventions revised

    International Nuclear Information System (INIS)

    Reyners, P.

    2004-01-01

    The signature on 12 February 2004 of the Protocols amending respectively the 1960 Paris Convention and the 1963 Brussels Supplementary Convention was the second step of the process of modernisation of the international nuclear liability regime after the adoption in September 1997 of a Protocol revising the 1963 Vienna Convention and of a new Convention on Supplementary Compensation for Nuclear Damage. The common objective of the new instruments is to provide more funds to compensate a larger number of potential victims in respect of a broader range of damage. Another goal of the revision exercise was to maintain the compatibility between the Paris and Vienna based systems, a commitment enshrined in the 1988 Joint Protocol, as well as to ascertain that Paris/Brussels countries could also become a Party to the Convention on Supplementary Compensation. However, while generally consistent vis a vis the Joint Protocol, the provisions of the Paris and Vienna Conventions, as revised, differ on some significant aspects. Another remaining issue is whether the improved international nuclear liability regime will succeed in attracting in the future a larger number of countries, particularly outside Europe, and will so become truly universal. Therefore, the need for international co-operation to address these issues, to facilitate the adoption of new implementing legislation and to ensure that this special regime keeps abreast of economic and technological developments, is in no way diminished after the revision of the Conventions.(author)

  8. Water screen

    Energy Technology Data Exchange (ETDEWEB)

    Kutepov, A.I.; Fedotov, I.N.; Prokopov, O.I.

    1981-01-01

    The invention refers to ventilation and can be used for repair-fitting operations in a blasting-dangerous gas condition, for example, during elimination of gas-oil gushers, repair of gas-oil pipelines, equipment etc. In order to improve safety of labor, the nozzle adapters of the water collector are oriented towards each other. The collector is installed on a support with the possibility of rotating and vertical movement. The proposed screen excludes the possibility of blasting-dangerous concentrations of gases and guarantees extinguishing of the impact spark during operation of the tool.

  9. RBC Antibody Screen

    Science.gov (United States)

    ... C Cystic Fibrosis (CF) Gene Mutations Testing Cytomegalovirus (CMV) Tests D-dimer Dengue Fever Testing Des-gamma- ... Index of Screening Recommendations Not Listed? Not Listed? Newborn Screening Screening Tests for Infants Screening Tests for ...

  10. Mental Health Screening Center

    Science.gov (United States)

    ... Releases & Announcements Public Service Announcements Partnering with DBSA Mental Health Screening Center These online screening tools are not ... you have any concerns, see your doctor or mental health professional. Depression Screening for Adult Depression Screening for ...

  11. Breast cancer screening

    Science.gov (United States)

    Mammogram - breast cancer screening; Breast exam - breast cancer screening; MRI - breast cancer screening ... is performed to screen women to detect early breast cancer when it is more likely to be cured. ...

  12. The evolution of development conventions

    Directory of Open Access Journals (Sweden)

    Fabio Stefano Erber

    2012-04-01

    Full Text Available This paper presents a conceptual view on development and its translation into development policies. It argues that society's perception of development is structured by conventions, which provide a view of the past, present and future and, at the same time, allows a certain hierarchy of problems and solutions to such problems. The prevalence of a specific convention depends on the international conditions faced by this society and on the distribution of economic and political power within that society. Therefore, in complex societies there is always a struggle for hegemony between competing development conventions.

  13. Demens Film

    DEFF Research Database (Denmark)

    Ridder, Hanne Mette Ochsner

    2012-01-01

    I forbindelse med opstarten af Demens Film projektet har der været nedsat en ekspertgruppe, som er kommet med en række anbefalinger omkring film til mennesker med demens. Anbefalingerne skal bruges i de næste faser af projektet. Deltagerne i ekspertgruppen var sammensat af en bred gruppe...... fagpersoner inde for forskellige fagområder. Læs mere om gruppens anbefalinger og sammensætning af ekspertgruppen i den kort rapport som er offentlig tilgængelig. Læs Ekspertgruppe anbefalingerne til Demens Film projekt....

  14. High-throughput characterization of film thickness in thin film materials libraries by digital holographic microscopy

    International Nuclear Information System (INIS)

    Lai Yiuwai; Hofmann, Martin R; Ludwig, Alfred; Krause, Michael; Savan, Alan; Thienhaus, Sigurd; Koukourakis, Nektarios

    2011-01-01

    A high-throughput characterization technique based on digital holography for mapping film thickness in thin-film materials libraries was developed. Digital holographic microscopy is used for fully automatic measurements of the thickness of patterned films with nanometer resolution. The method has several significant advantages over conventional stylus profilometry: it is contactless and fast, substrate bending is compensated, and the experimental setup is simple. Patterned films prepared by different combinatorial thin-film approaches were characterized to investigate and demonstrate this method. The results show that this technique is valuable for the quick, reliable and high-throughput determination of the film thickness distribution in combinatorial materials research. Importantly, it can also be applied to thin films that have been structured by shadow masking.

  15. High-throughput characterization of film thickness in thin film materials libraries by digital holographic microscopy.

    Science.gov (United States)

    Lai, Yiu Wai; Krause, Michael; Savan, Alan; Thienhaus, Sigurd; Koukourakis, Nektarios; Hofmann, Martin R; Ludwig, Alfred

    2011-10-01

    A high-throughput characterization technique based on digital holography for mapping film thickness in thin-film materials libraries was developed. Digital holographic microscopy is used for fully automatic measurements of the thickness of patterned films with nanometer resolution. The method has several significant advantages over conventional stylus profilometry: it is contactless and fast, substrate bending is compensated, and the experimental setup is simple. Patterned films prepared by different combinatorial thin-film approaches were characterized to investigate and demonstrate this method. The results show that this technique is valuable for the quick, reliable and high-throughput determination of the film thickness distribution in combinatorial materials research. Importantly, it can also be applied to thin films that have been structured by shadow masking.

  16. The Monte Carlo evaluation of noise and resolution properties of granular phosphor screens

    International Nuclear Information System (INIS)

    Liaparinos, P F; Kandarakis, I S

    2009-01-01

    The imaging performance of phosphor screens, used as x-ray detectors in diagnostic medical imaging systems, is affected by their both noise and resolution properties. Amplification and blurring processes are due to a sequence of conversion stages within the screen which contribute to fluctuations in the number and spatial distribution of the optical quanta recorded by the optical detector (e.g. film, television camera, CCD, etc). The purpose of this paper is to investigate the stochastic noise arising from granularity as well as the variation of spatial resolution of granular fluorescent screens in terms of the detector's structure. Using a custom-validated Monte Carlo model, the parameters of interest were evaluated for the widely used Gd 2 O 2 S:Tb phosphor material. We have studied the variations of (i) the modulation transfer function, (ii) the Swank factor and (iii) the zero-frequency detective quantum efficiency (DQE), under several conditions employed in conventional and digital mammography and radiology. Several evaluations are provided for the imaging metrics as a function of the x-ray energy (18 keV, 49 keV and 51 keV), phosphor coating weight (20 mg cm -2 , 34 mg cm -2 and 60 mg cm -2 ), grain size (from 4 μm up to 13 μm) and packing density (from 50% up to 85%). It was found that screens of high packing density can combine high zero-frequency DQE with improved resolution properties. For a digital mammographic imaging system (34 mg cm -2 , 18 keV), a packing density of 85% can improve the spatial resolution of the screen by 1.6 cycles mm -1 in comparison to that of 50% packing density. Similarly, for radiographic cases (60 mg cm -2 , 49 keV), the spatial resolution can be improved by 1.7 cycles mm -1 . The aforementioned findings provide the resolution benefits of using high packing density screens.

  17. SCREENING THE SOCIAL FACE OF DENMARK TO THE NAZIS

    DEFF Research Database (Denmark)

    Ørskov, Frederik Forrai

    2018-01-01

    Looking into the state-sponsored creation and presentation of a German-language film on the Danish social state, this article discusses the complexities of Danish–German relations during the German occupation of Denmark, 1940–1945. The film, Das soziale Gesicht Dänemarks, was screened in Berlin...... to a full house, including a number of Nazi notables, and followed by a presentation by the Danish Minister of Labor and Social Affairs. Based on archival research and film analysis, the article argues that the screening in Berlin informs an understanding of an asymmetrical power relationship between...

  18. Study of secondary X-rays from radiographic intensifying screens

    International Nuclear Information System (INIS)

    Barroso, R.C.; Eichler, J.; Lopes, R.T.; Cardoso, S.C.

    1998-01-01

    To reduce the radiation dose in radiology, fluorescent intensifying screens for X-ray films are used. They produce visible light which increases the efficiency of the film. In addition, there are two other effects that will degrade the image resolution. First, the gadolinium present in the screens produces X-rays isotropically. Second, the primary radiation can be scattered elastically (Rayleigh scattering) and inelastically (Compton scattering). The intensity and angular distribution of these secondary radiation were measured, showing that the ratio of secondary-to-primary radiation incident on the X-ray film is about 16%. (orig.)

  19. Evolutionary Games and Social Conventions

    DEFF Research Database (Denmark)

    Hansen, Pelle Guldborg

    2007-01-01

    -defined metaphors of individual learning and social imitation processes, from which a revised theory of convention may be erected (see Sugden 2004, Binmore 1993 and Young 1998). This paper makes a general argument in support of the evolutionary turn in the theory of convention by a progressive exposition of its...... in Aumann (1976) and which, together with the assumptions of perfect rationality, came to be defining of classical game theory. However, classical game theory is currently undergoing severe crisis as a tool for exploring social phenomena; a crisis emerging from the problem of equilibrium selection around......Some thirty years ago Lewis published his Convention: A Philosophical Study (Lewis, 2002). This laid the foundation for a game-theoretic approach to social conventions, but became more famously known for its seminal analysis of common knowledge; the concept receiving its canonical analysis...

  20. Paris convention - Decisions, recommendations, interpretations

    International Nuclear Information System (INIS)

    1990-01-01

    This booklet is published in a single edition in English and French. It contains decisions, recommendations and interpretations concerning the 1960 Paris Convention on Third Party Liability in the Field of Nuclear Energy adopted by the OECD Steering Committee and the OECD Council. All the instruments are set out according to the Article of the Convention to which they relate and explanatory notes are added where necessary [fr

  1. Polymer films

    Science.gov (United States)

    Granick, Steve; Sukhishvili, Svetlana A.

    2004-05-25

    A film contains a first polymer having a plurality of hydrogen bond donating moieties, and a second polymer having a plurality of hydrogen bond accepting moieties. The second polymer is hydrogen bonded to the first polymer.

  2. Positive predictive values by mammographic density and screening mode in the Norwegian Breast Cancer Screening Program.

    Science.gov (United States)

    Moshina, Nataliia; Ursin, Giske; Roman, Marta; Sebuødegård, Sofie; Hofvind, Solveig

    2016-01-01

    To investigate the probability of breast cancer among women recalled due to abnormal findings on the screening mammograms (PPV-1) and among women who underwent an invasive procedure (PPV-2) by mammographic density (MD), screening mode and age. We used information about 28,826 recall examinations from 26,951 subsequently screened women in the Norwegian Breast Cancer Screening Program, 1996-2010. The radiologists who performed the recall examinations subjectively classified MD on the mammograms into three categories: fatty (70%). Screening mode was defined as screen-film mammography (SFM) and full-field digital mammography (FFDM). We examined trends of PPVs by MD, screening mode and age. We used logistic regression to estimate odds ratio (OR) of screen-detected breast cancer associated with MD among women recalled, adjusting for screening mode and age. PPV-1 and PPV-2 decreased by increasing MD, regardless of screening mode (p for trend breasts. Among women recalled, the adjusted OR of breast cancer decreased with increasing MD. Compared with women with fatty breasts, the OR was 0.90 (95% CI: 0.84-0.96) for those with medium dense breasts and 0.85 (95% CI: 0.76-0.95) for those with dense breasts. PPVs decreased by increasing MD. Fewer women needed to be recalled or undergo an invasive procedure to detect one breast cancer among those with fatty versus dense breasts in the screening program in Norway, 1996-2010. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  3. Message films in Africa: A look into the past

    Directory of Open Access Journals (Sweden)

    Rachael Diang′a

    2016-12-01

    Full Text Available Message Film-making has characterised much of films produced in post-independent Kenya. The country produced very few films in the 1980s, when indigenous film-making actually began to take root. Liberalisation of the economy, embracement of the digital technology and democratization in the 1990s paved way for a more stable film culture in the decade. A more promising growth of the film industry has been largely witnessed since the turn of the 21st century. Through this period, I note a strong tendency to produce films that are loaded with social messages deemed urgent and important to the target audience. In making these films, the film-makers hope to make a positive impact in the lives of the target audiences. These films tend to valorise the message, sometimes, neglecting the basic filmic codes, a practice that renders the films less entertaining. This endangers the growth of the industry since local films find very stiff competition from foreign films that are common on Kenyan screens. This study therefore investigates possible roots of message film-making in Africa that directly influence the tendencies in Kenya by making references to other African countries’ film experiences. My assumption is that Kenya’s cultural experiences are shared by other African countries.

  4. CT and conventional radiographic techniques in interstitial pulmonary disease

    International Nuclear Information System (INIS)

    Leipner, N.; Schueller, H.; Uexkuell-Gueldenband, V. v.; Schlolaut, K.H.; Overlack, A.; Bonn Univ.

    1988-01-01

    One hundred and sixty-four patients with pulmonary fibrosis were examined by CT and by conventional radiological methods. Sixty patients had asbestosis, thirty-nine silicosis, forty sarcoidosis and twenty-five had idiopathic pulmonary fibrosis. CT is superior to conventional radiography in evaluating interstitial pulmonary changes, particularly of the pleura and the lung parenchyma. In sixty-nine patients there were some findings which could only be demonstrated by CT. In asbestosis, silicosis and sarcoidosis the CT classification of the lung parenchyma which we have suggested produces significantly better correlation with vital capacity than can be achieved from conventional chest films, according to the guidelines of the I.L.O. (orig./GDG) [de

  5. Breast cancer screening with digital breast tomosynthesis.

    Science.gov (United States)

    Skaane, Per

    2017-01-01

    To give an overview of studies comparing full-field digital mammography (FFDM) and digital breast tomosynthesis (DBT) in breast cancer screening. The implementation of tomosynthesis in breast imaging is rapidly increasing world-wide. Experimental clinical studies of relevance for DBT screening have shown that tomosynthesis might have a great potential in breast cancer screening, although most of these retrospective reading studies are based on small populations, so that final conclusions are difficult to draw from individual reports. Several retrospective studies and three prospective trials on tomosynthesis in breast cancer screening have been published so far, confirming the great potential of DBT in mammography screening. The main results of these screening studies are presented. The retrospective screening studies from USA have all shown a significant decrease in the recall rate using DBT as adjunct to mammography. Most of these studies have also shown an increase in the cancer detection rate, and the non-significant results in some studies might be explained by a lack of statistical power. All the three prospective European trials have shown a significant increase in the cancer detection rate. The retrospective and the prospective screening studies comparing FFDM and DBT have all demonstrated that tomosynthesis has a great potential for improving breast cancer screening. DBT should be regarded as a better mammogram that could improve or overcome limitations of the conventional mammography, and tomosynthesis might be considered as the new technique in the next future of breast cancer screening.

  6. In vitro corrosion and biocompatibility screening of sputtered Ti{sub 40}Cu{sub 36}Pd{sub 14}Zr{sub 10} thin film metallic glasses on steels

    Energy Technology Data Exchange (ETDEWEB)

    Subramanian, B., E-mail: subramanianb3@gmail.com

    2015-02-01

    The growth of multi-component thin film metallic glasses (TFMGs) of Ti{sub 40}Cu{sub 36}Pd{sub 14}Zr{sub 10} (at.%) alloys fabricated using magnetron sputtering on bioimplantable 316L stainless steel substrates has been investigated. The vapor–solid quenching during sputtering enables the amorphous phases to be formed. The amorphous films consist of a single glassy phase, as evidenced by a broad hump and no detectable crystalline peaks as observed from XRD and selective area electron diffraction (SAED) patterns. The average surface roughness (Ra) of the coated film as observed from AFM was 0.3 nm. Nanohardness of about 7.7 GPa and Young's modulus of 110 GPa were measured from nanoindentation analysis. The potentiodynamic polarization and impedance measurements showed that coated stainless steel substrates have higher corrosion resistance compared to uncoated SS substrate in simulated body fluid (SBF) solution. The cytotoxicity studies using L929 fibroblast cells showed that these coatings were non-cytotoxic in nature. The interactions between the coated surface and bacteria were investigated by agar diffusion method, solution suspension and wet interfacial contact methods. - Highlights: • Ti-based TFMG coated specimen showed superior corrosion resistance. • Ti-based TFMG coated SS 316L specimen was non-cytotoxic in nature. • Antimicrobial activity of Ti-based TFMG was noticed.

  7. Realistic absorption coefficient of ultrathin films

    Science.gov (United States)

    Cesaria, M.; Caricato, A. P.; Martino, M.

    2012-10-01

    Both a theoretical algorithm and an experimental procedure are discussed of a new route to determine the absorption/scattering properties of thin films deposited on transparent substrates. Notably, the non-measurable contribution of the film-substrate interface is inherently accounted for. While the experimental procedure exploits only measurable spectra combined according to a very simple algorithm, the theoretical derivation does not require numerical handling of the acquired spectra or any assumption on the film homogeneity and substrate thickness. The film absorption response is estimated by subtracting the measured absorption spectrum of the bare substrate from that of the film on the substrate structure but in a non-straightforward way. In fact, an assumption about the absorption profile of the overall structure is introduced and a corrective factor accounting for the relative film-to-substrate thickness. The method is tested on films of a well known material (ITO) as a function of the film structural quality and influence of the film-substrate interface, both deliberately changed by thickness tuning and doping. Results are found fully consistent with information obtained by standard optical analysis and band gap values reported in the literature. Additionally, comparison with a conventional method demonstrates that our route is generally more accurate even if particularly suited for very thin films.

  8. Effects of Adopting Different Kinds of Collecting Method for Years on Film Residual Coefficient and Maize Yields

    OpenAIRE

    TANG Wen-xue; MA Zhong-ming; WEI Tao

    2017-01-01

    Wide usage of mulching technology has increased crop yields, but the large amounts of mulching film residue resulting from widespread use of plastic film in China has brought about a series of pollution hazards. Based on a 4-year (2011-2014) long-term experiment, the effects of different kinds of collecting mothod (zero plastic film residues, conventional plastic film residues, whole plastic film residues remainded) on plastic film residues, residual coefficient and maize yield were explored....

  9. (re)collections: fragments for a retrospective film script for "Project SBSBI"

    OpenAIRE

    Gent, Susannah

    2015-01-01

    This is an experiment in writing a section of a film script for a film which has not been written. The film employs a layered audio and narrative approach which aims to promote a non conventional viewing experience where different ‘stories’ compete for attention, and unlike the traditional film, evades a fixed reading. \\ud Due to its form and creative approach, the film is being constructed in a spontaneous and reflective manner. The prospect of writing the script is necessarily retrospective...

  10. NESTA Revolutionizing Teacher's Experiences at NSTA Conventions

    Science.gov (United States)

    Ireton, F.

    2002-05-01

    National Science Teachers Association (NSTA) conventions are traditionally composed of short workshops, half or full day workshops, and lectures on science teaching or education research. Occasional science lectures such as the AGU lecture offer science content information. The National Earth Science Teachers Association (NESTA) will join the National Association of Geoscience Teachers (NAGT), American Geophysical Union (AGU), and the American Geological Institute (AGI) to bring teachers a suite of exciting and informative events at the (NSTA) 2002 convention. Events begin with a guided learning field trip to Mission Trails Regional Park and Torrey Pines State Reserve where Earth and space science teachers experience a model of constructivist leaning techniques. Most field trips are a "show and tell" experience, designed to transmit knowledge from the field trip leader to the field trip participants. In the "guided learning" environment, the leader serves as a facilitator, asking questions, guiding participants to discover concepts for themselves. Participants examine selected processes and features that constitute a constructivist experience in which knowledge acquired at any given location builds on knowledge brought to the site. Employing this strategy involves covering less breadth but greater depth, modeling the concept of "less is more." On Thursday NESTA will host two Share-a-thons. These are not what a person would think of as a traditional workshop where presenter makes a presentation then the participants work on an activity. They could be called the flea market of teaching ideas. Tables are set around the perimeter of a room where the presenters are stationed. Teachers move from table to table picking up information and watching short demonstrations. The Earth and Space Science Resource Day on Friday will focus on teachers needs. Starting with breakfast, teachers will hear from Soames Summerhays, Naturalist and President of Summerhays Films, about how he

  11. Novel versus conventional antipsychotic drugs.

    Science.gov (United States)

    Love, R C

    1996-01-01

    Novel antipsychotic agents differ from conventional ones in several key characteristics, including effectiveness, adverse reactions, and receptor-binding profile. Most of the newer agents have an affinity for the serotonin 5HT2 receptor that is at least 10 times greater than that for the dopamine D2 receptor. This increased affinity for the serotonin receptor may be responsible for another distinguishing characteristic of novel antipsychotic agents--decreased frequency of extrapyramidal side effects. These side effects, which include pseudoparkinsonism, acute dystonias, and akathisia, frequently are the reason for noncompliance with conventional drug therapy. The newer drugs are often effective in patients resistant to treatment with conventional agents. They also appear to reduce the negative symptoms of schizophrenia in many patients.

  12. The prospect of conventional disarmament

    International Nuclear Information System (INIS)

    Adeniji, O.

    1989-01-01

    The prospect of conventional disarmament in Europe holds out great consequences not only for the continent but also for the entire world. The arms race both in its nuclear and conventional aspects has been the single most important element of the destabilizing factors in international relations since 1945. Though initially borne out of the ideological division of Europe and the consequent quest for strategic military superiority, it soon developed a technological momentum of its own, becoming more the cause than the effect of the distrust in the relationship of the two alliances. The issue of conventional weapons was raised for negotiations side by side with that of nuclear weapons when the United Nations took up the question of disarmament in 1946. Due, however, to the unforeseen and most dangerous advance in nuclear weaponry, the fear engendered shifted all attention at the multilateral level to nuclear weapons. Except in Europe where the Mutual and Balanced Force Reduction Talks in Central Europe were initiated, conventional weapons disarmament did not attract multilateral attention again until the First Special Session of the United nations General Assembly Devoted to Disarmament in 1978. The Final Document of the Special Session did accord highest priority to negotiations on nuclear weapons. However, it also affirmed that side by side with negotiations on nuclear weapons, the limitation and gradual reduction of armed forces and conventional weapons should be resolutely pursued within the framework of general and complete disarmament. States with the largest military arsenals, it was stated, had a special responsibility in pursuing conventional armaments reduction. Underscoring the central role of Europe further, the Final Document postulated that the achievement of a more stable situation at a lower level of military potential would contribute toward strengthening of security in Europe and constitute a significant step toward international peace and security

  13. Conventional imaging in paediatric uroradiology

    International Nuclear Information System (INIS)

    Riccabona, M.; Lindbichler, F.; Sinzig, M.

    2002-01-01

    Objective: To briefly describe basic conventional imaging in paediatric uroradiology. Method: The state of the art performance of standard imaging techniques (intravenous urography (IVU), voiding cystourethrography (VCU), and ultrasound (US)) is described, with emphasis on technical aspects, indications, and patient preparation such as adequate hydration. Only basic applications as used in routine clinical work are included. Result and conclusion: Conventional imaging methods are irreplaceable. They cover the majority of daily clinical routine queries, with consecutive indication of more sophisticated modalities in those patients who need additional imaging for establishing the final diagnosis or outlining therapeutic options

  14. Conventional imaging in paediatric uroradiology

    Energy Technology Data Exchange (ETDEWEB)

    Riccabona, M. E-mail: michael.riccabona@kfunigraz.ac.at; Lindbichler, F.; Sinzig, M

    2002-08-01

    Objective: To briefly describe basic conventional imaging in paediatric uroradiology. Method: The state of the art performance of standard imaging techniques (intravenous urography (IVU), voiding cystourethrography (VCU), and ultrasound (US)) is described, with emphasis on technical aspects, indications, and patient preparation such as adequate hydration. Only basic applications as used in routine clinical work are included. Result and conclusion: Conventional imaging methods are irreplaceable. They cover the majority of daily clinical routine queries, with consecutive indication of more sophisticated modalities in those patients who need additional imaging for establishing the final diagnosis or outlining therapeutic options.

  15. The European Convention on bioethics.

    Science.gov (United States)

    Byk, C

    1993-03-01

    Benefiting from a widely recognised experience of the field of bioethics, the Council of Europe which represents all the democratic countries of Europe, has embarked on the ambitious task of drafting a European Convention on bioethics. The purpose of this text is to set out fundamental values, such as respect for human dignity, free informed consent and non-commercialisation of the human body. In addition to this task, protocols will provide specific standards for the different fields concerned with the application of biomedical sciences. The convention and the first two protocols (human experiments and organ transplants) are due to be ready for signature by mid 1994.

  16. Conventional and unconventional political participation

    International Nuclear Information System (INIS)

    Opp, K.D.

    1985-01-01

    A non-recursive model is proposed and empirically tested with data of opponents of nuclear power. In explaining conventional and unconventional participation the theory of collective action is applied and modified in two respects: the perceived influence on the elimination of collective evils are taken into account; the selective incentives considered are non-material ones. These modifications proved to be valid: the collective good variables and non-material incentives were important determinants for the two forms of participation. Another result was that there is a reciprocal causal relationship between conventional and unconventional participation. (orig./PW) [de

  17. Digital mammography in breast cancer screening: Evaluation and innovation

    NARCIS (Netherlands)

    Bluekens, A.M.J.

    2015-01-01

    With all other imaging modalities in radiology being digitised and conventional mammography being ready to phase out the transition to digital mammography was inevitable. This thesis describes the performance of digital screening mammography and the consequences of implementation in a

  18. Solar advanced internal film receiver

    International Nuclear Information System (INIS)

    Torre Cabezas, M. de la

    1990-01-01

    In a Solar Central Internal Film Receiver, the heat absorbing fluid (a molten nitrate salt) flows in a thin film down over the non illuminated side of an absorber panel. Since the molten salt working fluid is not contained in complicated tube manifolds, the receiver design is simples than a conventional tube type-receiver resulting in a lower cost and a more reliable receiver. The Internal Film Receiver can be considered as an alternative to the Direct Absorption Receiver, in the event that the current problems of the last one can not be solved. It also describes here the test facility which will be used for its solar test, and the test plans foreseen. (Author) 17 refs

  19. Science Fiction on Film.

    Science.gov (United States)

    Burmester, David

    1985-01-01

    Reviews science fiction films used in a science fiction class. Discusses feature films, short science fiction films, short story adaptations, original science fiction pieces and factual science films that enrich literature. (EL)

  20. Exploring the Legacies of Filmed Patient Narratives

    Science.gov (United States)

    Robert, Glenn; Maben, Jill

    2015-01-01

    We trace the legacies of filmed patient narratives that were edited and screened to encourage engagement with a participatory quality improvement project in an acute hospital setting in England. Using Gabriel’s theory of “narrative contract,” we examine the initial success of the films in establishing common grounds for participatory project and later, and more varied, interpretations of the films. Over time, the films were interpreted by staff as either useful sources of learning by critical reflection, dubious (invalid or unreliable) representations of patient experience, or as “closed” items available as auditable evidence of completed quality improvement work. We find these interpretations of the films to be shaped by the effect of social distance, the differential outcomes of project work, and changing organizational agendas. We consider the wider conditions of patient narrative as a form of quality improvement knowledge with immediate potency and fragile or fluid legitimacy over time. PMID:25576480