WorldWideScience

Sample records for conventional imaging position

  1. Double oblique MR images of the shoulder. Comparison with conventional images

    International Nuclear Information System (INIS)

    Sasaki, Taisuke; Saito, Yoko; Yodono, Hiraku; Miura, Hiroyuki; Shinohara, Atsushi; Abe, Shuichiro

    1998-01-01

    Because the scapula is not only slanted on transverse sections but also inclines on sagittal sections, we now perform shoulder MR imaging using double oblique images (DOI), which are planes perpendicular or parallel to the long axis of the scapula obtained with oblique sagittal scout imaging. The purpose of this study was to evaluate the usefulness of double oblique shoulder MR imaging. MR images of shoulders with operatively or arthroscopically proven lesions (20 cases) that had been examined on both conventional images (CI) and DOI were retrospectively reviewed. DOI were compared with CI not only in terms of diagnostic performance but also in their ability to identify the details of shoulder anatomy. All MR studies were done with a shoulder coil on a high-field (1.5 T) unit. Although the accuracy of DOI in diagnosing shoulder disorders such as rotator cuff tear and labrum injury was not as good as that of CI, DOI were better for identifying or discriminating muscles and tendons of the rotator cuff, labralbicipital junction and anterior band of the inferior gleno-humeral ligament, and for recognizing the correct position of the glenoid labrum. MR double oblique imaging of the shoulder provides more detailed information about shoulder anatomy and disorders than conventional imaging. (author)

  2. Comparative effects of Facebook and conventional media on body image dissatisfaction.

    Science.gov (United States)

    Cohen, Rachel; Blaszczynski, Alex

    2015-01-01

    Appearance comparison has consistently been shown to engender body image dissatisfaction. To date, most studies have demonstrated this relationship between appearance comparison and body image dissatisfaction in the context of conventional media images depicting the thin-ideal. Social comparison theory posits that people are more likely to compare themselves to similar others. Since social media forums such as Facebook involve one's peers, the current study aimed to determine whether the relationship between appearance comparison and body image dissatisfaction would be stronger for those exposed to social media images, compared to conventional media images. A sample of 193 female first year university students were randomly allocated to view a series of either Facebook or conventional media thin-ideal images. Participants completed questionnaires assessing pre- and post- image exposure measures of thin-ideal internalisation, appearance comparison, self-esteem, Facebook use and eating disorder risk. Type of exposure was not found to moderate the relationship between appearance comparison and changes in body image dissatisfaction. When analysed according to exposure type, appearance comparison only significantly predicted body image dissatisfaction change for those exposed to Facebook, but not conventional media. Facebook use was found to predict higher baseline body image dissatisfaction and was associated with higher eating disorder risk. The findings suggest the importance of extending the body image dissatisfaction literature by taking into account emerging social media formats. It is recommended that interventions for body image dissatisfaction and eating disorders consider appearance comparison processes elicited by thin-ideal content on social media forums, such as Facebook, in addition to conventional media.

  3. Conventional imaging in paediatric uroradiology

    International Nuclear Information System (INIS)

    Riccabona, M.; Lindbichler, F.; Sinzig, M.

    2002-01-01

    Objective: To briefly describe basic conventional imaging in paediatric uroradiology. Method: The state of the art performance of standard imaging techniques (intravenous urography (IVU), voiding cystourethrography (VCU), and ultrasound (US)) is described, with emphasis on technical aspects, indications, and patient preparation such as adequate hydration. Only basic applications as used in routine clinical work are included. Result and conclusion: Conventional imaging methods are irreplaceable. They cover the majority of daily clinical routine queries, with consecutive indication of more sophisticated modalities in those patients who need additional imaging for establishing the final diagnosis or outlining therapeutic options

  4. Conventional imaging in paediatric uroradiology

    Energy Technology Data Exchange (ETDEWEB)

    Riccabona, M. E-mail: michael.riccabona@kfunigraz.ac.at; Lindbichler, F.; Sinzig, M

    2002-08-01

    Objective: To briefly describe basic conventional imaging in paediatric uroradiology. Method: The state of the art performance of standard imaging techniques (intravenous urography (IVU), voiding cystourethrography (VCU), and ultrasound (US)) is described, with emphasis on technical aspects, indications, and patient preparation such as adequate hydration. Only basic applications as used in routine clinical work are included. Result and conclusion: Conventional imaging methods are irreplaceable. They cover the majority of daily clinical routine queries, with consecutive indication of more sophisticated modalities in those patients who need additional imaging for establishing the final diagnosis or outlining therapeutic options.

  5. Comparative effects of Facebook and conventional media on body image dissatisfaction

    OpenAIRE

    Cohen, Rachel; Blaszczynski, Alex

    2015-01-01

    Background Appearance comparison has consistently been shown to engender body image dissatisfaction. To date, most studies have demonstrated this relationship between appearance comparison and body image dissatisfaction in the context of conventional media images depicting the thin-ideal. Social comparison theory posits that people are more likely to compare themselves to similar others. Since social media forums such as Facebook involve one?s peers, the current study aimed to determine wheth...

  6. The establishment of Digital Image Capture System(DICS) using conventional simulator

    International Nuclear Information System (INIS)

    Oh, Tae Sung; Park, Jong Il; Byun, Young Sik; Shin, Hyun Kyoh

    2004-01-01

    The simulator is used to determine patient field and ensure the treatment field, which encompasses the required anatomy during patient normal movement such as during breathing. The latest simulator provide real time display of still, fluoroscopic and digitalized image, but conventional simulator is not yet. The purpose of this study is to introduce digital image capture system(DICS) using conventional simulator and clinical case using digital captured still and fluoroscopic image. We connect the video signal cable to the video terminal in the back up of simulator monitor, and connect the video jack to the A/D converter. After connection between the converter jack and computer, We can acquire still image and record fluoroscopic image with operating image capture program. The data created with this system can be used in patient treatment, and modified for verification by using image processing software. (j.e. photoshop, paintshop) DICS was able to establish easy and economical procedure. DCIS image was helpful for simulation. DICS imaging was powerful tool in the evaluation of the department specific patient positioning. Because the commercialized simulator based of digital capture is very expensive, it is not easily to establish DICS simulator in the most hospital. DICS using conventional simulator enable to utilize the practical use of image equal to high cost digitalized simulator and to research many clinical cases in case of using other software program.

  7. Ankle ligamints : comparison of MR arthrography with conventional MR imaging in amputated feet

    International Nuclear Information System (INIS)

    Yoo, Jae Sung; Lee, Sang Yong; Lee, Jeong Min; Han, Young Min; Chung, Kyung Ho; Kim, CHong Soo

    2001-01-01

    To compare magnetic resonance (MR) arthrography with conventional MR imaging in the evaluation of ankle ligaments. Eight freshly amputated human feet underwent conventional MR imaging and MR arthrography. For the former, 1.5-T magnets in the axial, coronal and sagittal planes were used, and T1-weighted sequences were obtained. Following the injection of 6-10 ml of diluted contrast media (Gd-DTPA 1:250), T1-weighted images were obtained in the same positions as conventional MR images. Paired conventional MR imaging and MR arthrography of each ankle ligament were rated on a five-point scale, and to reflect inter-group differences a Wilcoxon singed-rank test was used to compare the different measurements (p<0.05). In two ankles, MR images of the ligaments were correlated with ankle dissection. Anterior and posterior talofibular ligaments were more clearly revealed by MR arthrography than by conventional MR imaging, while calcaneofibular ligaments showed no difference between these two modalities. With regard to deltoid ligaments, visualization of the anterior and posterior tibiotalar ligament was much improved when contrast material was used to outline the ligament's articular aspect. Visualization of the posterior inferior tibiofibular ligament and inferior transverse ligament were also improved when the use of contrast material provided delineation of the articular side of the ligaments and separated them from adjacent bone. In addition, MR arthography was very useful for indentification of the posterior intermalleolar ligament, though its use did not enhance visualization of the calcaneofibular, tibiocalcaneal, spring or tibiospring ligaments. MR arthrography accurately revealed the anatomic details of ankle ligaments, and may therefore be more useful than conventional Mr imaging for evaluation of these structures

  8. Method for automatic localization of MR-visible markers using morphological image processing and conventional pulse sequences: feasibility for image-guided procedures.

    Science.gov (United States)

    Busse, Harald; Trampel, Robert; Gründer, Wilfried; Moche, Michael; Kahn, Thomas

    2007-10-01

    To evaluate the feasibility and accuracy of an automated method to determine the 3D position of MR-visible markers. Inductively coupled RF coils were imaged in a whole-body 1.5T scanner using the body coil and two conventional gradient echo sequences (FLASH and TrueFISP) and large imaging volumes up to (300 mm(3)). To minimize background signals, a flip angle of approximately 1 degrees was used. Morphological 2D image processing in orthogonal scan planes was used to determine the 3D positions of a configuration of three fiducial markers (FMC). The accuracies of the marker positions and of the orientation of the plane defined by the FMC were evaluated at various distances r(M) from the isocenter. Fiducial marker detection with conventional equipment (pulse sequences, imaging coils) was very reliable and highly reproducible over a wide range of experimental conditions. For r(M) position and angular orientation were 1.7 mm and 0.33 degrees , respectively. For r(M) image processing is feasible, simple, and very accurate. In combination with safe wireless markers, the method is found to be useful for image-guided procedures. (c) 2007 Wiley-Liss, Inc.

  9. SU-E-I-88: Mammography Imaging: Does Positioning Matter?

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, J; Szabunio, M [University of Kentucky, Lexington, KY (United States)

    2014-06-01

    Purpose: In mammography, compression is imperative for quality images and glandular radiation exposure dose. The thickness of the compressed breast directly determines mammography acquisition parameters. The compressed thickness varies due to variation in technologist practice, even for the same patient imaged at different time. This study is to investigate potential effect of the variation in breast positioning on radiation dose and image quality. Methods: Radiation dose at different thicknesses was measured with a BR-12 breast phantom for both conventional craniocaudal view and tomosynthesis in a Hologic Tomosynthesis mammography system. The CIRS stereotactic needle biopsy training phantom embedded dense masses and microcalcification in various sizes were imaged for image quality evaluation. Radiologists evaluated images. Clinical mammograms from the same patient but acquired at different time were retrospectively retrieved to evaluate potential effects of variation in positioning. Results: Acquisition parameters (kVp and mAs) increase with the increased phantom thickness. Radiation exposure increases following an exponential trend. The stereotactic phantom images showed loss of spatial and contrast resolution with inappropriate positioning. The compressed pressure may not be a good indicator for appropriate positioning. The inclusion of different amount of pectoralis muscle may lead to the same compressed pressure but different compressed thickness. The initial retrospective study of 3 patients showed that there were potential large variations in positioning the same patient at different examination time, resulting in large variations in patient radiation dose and image quality. Conclusion: Variations in patient positioning potentially influence patient radiation dose and image quality. The technologist has the critical responsibility to position patient to provide quality images in spite of different breast and body types. To reduce intra and inter practice

  10. Digital imaging in conventional diagnostic radiology: status and trends

    International Nuclear Information System (INIS)

    Pfeiler, M.; Marhoff, P.; Schipper, P.

    1984-01-01

    Digital techniques, i.e. techniques using microcomputers of minicomputers, are getting increasingly common in so-called conventional radiography. These nonreconstructive techniques are referred to here as 'digital, direct-imaging radiography' in order to contrast them with the reconstructive techniques of computerized tomography. Digitalisation of imaging and image processing operation and control will change the jobs of the radiologist and radiological assistants in such manner that only X-ray units with film-foil systems or with X-ray image intensification should be classified as conventional systems. Digital and conventional systems differ in that digital techniques imply the possibility of establishing data pools which may eventually be developed into a digital image interconnection and archiving system. The authors first describe the general system in which the digital imaging systems must be integrated on a medium-term and long-term basis and then proceed to discuss digital imaging and image processing in some more detail. (orig./WU) [de

  11. Meniscal tears: comparison of half-Fourier technique and conventional MR imaging

    International Nuclear Information System (INIS)

    Shabana, Wael; Maeseneer, Michel de; Machiels, Freddy; Ridder, Filip de; Osteaux, Michel

    2003-01-01

    Purpose: To determine whether half-Fourier MR image acquisition technique can provide similar information to that of conventional MR acquisition technique for evaluation of meniscal tears. Materials and methods: We studied 101 menisci in 52 patients who were referred for evaluation of meniscal tears. Sagittal MR images of the knee were obtained for all patients by using proton density and T2-weighted SE sequences on a 1-T clinical system. The half-Fourier technique and conventional technique were used for all patients. All other imaging parameters were identical for both sequences (TR/TE=2400/20,70; 3 mm slice thickness; 200x256 matrix; field of view, 200; one signal acquired). Both sets of images were filmed with standard window and level settings. Images were randomised and interpreted independently by two radiologists for the presence of meniscal tears. Images were also subjectively assessed for image quality using a five-point grading scale. Results: On half-Fourier images, Reader 1 interpreted 23 menisci as torn, compared to 28 for Reader 2. On conventional images, Reader 1 interpreted 24 menisci as torn, compared to 26 for Reader 2. Agreement between interpretation of the conventional and that of the half-Fourier images was 99% for Reader 1, and 98% for Reader 2. Agreement between readers for the half-Fourier images was 95%, and for the conventional images 96%. No statistically significant difference was found in the subjective evaluation of image quality between the conventional and half-Fourier images. Conclusion: The half-Fourier acquisition technique compares favourably with the conventional technique for the evaluation of meniscal tears

  12. Postmortem cardiovascular magnetic resonance imaging in fetuses and children: a masked comparison study with conventional autopsy.

    Science.gov (United States)

    Taylor, Andrew M; Sebire, Neil J; Ashworth, Michael T; Schievano, Silvia; Scott, Rosemary J; Wade, Angie; Chitty, Lyn S; Robertson, Nikki; Thayyil, Sudhin

    2014-05-13

    Perinatal and pediatric autopsies have declined worldwide in the past decade. We compared the diagnostic accuracy of postmortem, cardiovascular magnetic resonance (CMR) imaging with conventional autopsy and histopathology assessment in fetuses and children. We performed postmortem magnetic resonance imaging in 400 fetuses and children, using a 1.5-T Siemens Avanto magnetic resonance scanner before conventional autopsy. A pediatric CMR imager reported the CMR images, masked to autopsy information. The pathologists were masked to the information from CMR images. The institutional research ethics committee approved the study, and parental consent was obtained. Assuming a diagnostic accuracy of 50%, 400 cases were required for a 5% precision of estimate. Three cases were excluded from analysis, 2 with no conventional autopsy performed and 1 with insufficient CMR sequences performed. Thirty-eight CMR data sets were nondiagnostic (37 in fetuses ≤24 weeks; 1 in a fetus >24 weeks). In the remaining 359 cases, 44 cardiac abnormalities were noted at autopsy. Overall sensitivity and specificity (95% confidence interval) of CMR was 72.7% (58.2-83.7%) and 96.2% (93.5-97.8%) for detecting any cardiac pathology, with positive and negative predictive values of 72.7% (58.2-83.7%) and 96.2% (93.5-97.8%), respectively. Higher sensitivity of 92.6% (76.6-97.9%), specificity of 99.1% (97.4-99.7%), positive predictive value of 89.3% (72.8-96.3%), and negative predictive value of 99.4% (97.8-99.8%) were seen for major structural heart disease. Postmortem CMR imaging may be a useful alternative to conventional cardiac autopsy in fetuses and children for detecting cardiac abnormalities. http://www.clinicaltrials.gov. Unique identifier: NCT01417962.

  13. Image quality of conventional images of dual-layer SPECTRAL CT: a phantom study.

    Science.gov (United States)

    van Ommen, F; Bennink, E; Vlassenbroek, A; Dankbaar, J W; Schilham, A M R; Viergever, M A; de Jong, H W A M

    2018-05-10

    Spectral CT using a dual layer detector offers the possibility of retrospectively introducing spectral information to conventional CT images. In theory, the dual-layer technology should not come with a dose or image quality penalty for conventional images. In this study, we evaluate the influence of a dual-layer detector (IQon Spectral CT, Philips) on the image quality of conventional CT images, by comparing these images with those of a conventional but otherwise technically comparable single-layer CT scanner (Brilliance iCT, Philips), by means of phantom experiments. For both CT scanners conventional CT images were acquired using four adult scanning protocols: i) body helical, ii) body axial, iii) head helical and iv) head axial. A CATPHAN 600 phantom was scanned to conduct an assessment of image quality metrics at equivalent (CTDI) dose levels. Noise was characterized by means of noise power spectra (NPS) and standard deviation (SD) of a uniform region, and spatial resolution was evaluated with modulation transfer functions (MTF) of a tungsten wire. In addition, contrast-to-noise ratio (CNR), image uniformity, CT number linearity, slice thickness, slice spacing, and spatial linearity were measured and evaluated. Additional measurements of CNR, resolution and noise were performed in two larger phantoms. The resolution levels at 50%, 10% and 5% MTF of the iCT and IQon showed small but significant differences up to 0.25 lp/cm for body scans, and up to 0.2 lp/cm for head scans in favor of the IQon. The iCT and IQon showed perfect CT linearity for body scans, but for head scans both scanners showed an underestimation of the CT numbers of materials with a high opacity. Slice thickness was slightly overestimated for both scanners. Slice spacing was comparable and reconstructed correctly. In addition, spatial linearity was excellent for both scanners, with a maximum error of 0.11 mm. CNR was higher on the IQon compared to the iCT for both normal and larger phantoms with

  14. Staging of untreated nasopharyngeal carcinoma with PET/CT: comparison with conventional imaging work-up

    International Nuclear Information System (INIS)

    Ng, Shu-Hang; Chan, Sheng-Chieh; Yen, Tzu-Chen; Liu, Feng-Yuan; Chang, Joseph Tung-Chieh; Fan, Kang-Hsing; Liao, Chun-Ta; Ko, Sheung-Fat; Chin, Shu-Chyn; Hsu, Cheng-Lung

    2009-01-01

    We prospectively compared PET/CT and conventional imaging for initial staging of nasopharyngeal carcinoma (NPC). A total of 111 patients with histologically proven NPC were investigated with PET/CT and conventional imaging (head-and-neck MRI, chest X-ray, abdominal ultrasound, and bone scan) before treatment. The respective findings were reviewed independently and then compared with each other. With regard to T staging, PET/CT showed a discrepancy with head-and-neck MRI in 36 (32.4%) of the study subjects. With regard to N staging, PET/CT showed a discrepancy with head-and-neck MRI in 15 (13.5%) patients. Among the discordant cases, MRI was superior in demonstrating tumor involvement in the parapharyngeal space, skull base, intracranial area, sphenoid sinus, and retropharyngeal nodes while PET/CT was superior in demonstrating neck nodal metastasis. PET/CT disclosed 13 of 16 patients with distant malignancy compared with four patients disclosed by conventional imaging work-up. The false-positive rate of PET/CT was 18.8%. PET/CT correctly modified M staging in eight patients (7.2%) and disclosed a second primary lung malignancy in one patient (0.9%). In NPC patients, MRI appears to be superior to PET/CT for the assessment of locoregional invasion and retropharyngeal nodal metastasis. PET/CT is more accurate than MRI for determining cervical nodal metastasis and should be the better reference for the neck status. PET/CT has an acceptable diagnostic yield and a low false-positive rate for the detection of distant malignancy and can replace conventional work-up to this aim. PET/CT and head-and-neck MRI are suggested for the initial staging of NPC patients. (orig.)

  15. The Value of Diffusion-Weighted Imaging in Combination With Conventional Magnetic Resonance Imaging for Improving Tumor Detection for Early Cervical Carcinoma Treated With Fertility-Sparing Surgery.

    Science.gov (United States)

    Li, Xiulei; Wang, Ling; Li, Yong; Song, Peiji

    2017-10-01

    This study aimed to investigate the value of diffusion-weighted imaging (DWI) in combination with conventional magnetic resonance imaging (MRI) for improving tumor detection in young patients treated with fertility-sparing surgery because of early cervical carcinoma. Fifty-four patients with stage Ia or Ib1 cervical carcinoma were enrolled into this study. Magnetic resonance examinations were performed for these patients using conventional MRI (including T1-weighted imaging, T2-weighted imaging, and dynamic contrast-enhanced MRI) and DWI. The apparent diffusion coefficient (ADC) values of cervical carcinoma were analyzed quantitatively and compared with that of adjacent epithelium. Sensitivity, positive predictive value, and accuracy of 2 sets of MRI sequences were calculated on the basis of histologic results, and the diagnostic ability of conventional MRI/DWI combinations was compared with that of conventional MRI. The mean ADC value from cervical carcinoma (mean, 786 × 10 mm/s ± 100) was significantly lower than that from adjacent epithelium (mean, 1352 × 10 mm/s ± 147) (P = 0.01). When the threshold ADC value set as 1010 × 10 mm/s, the sensitivity and specificity for differentiating cervical carcinoma from nontumor epithelium were 78.2% and 67.2%, respectively. The sensitivity and accuracy of conventional MRI for tumor detection were 76.0% and 70.4%, whereas the sensitivity and accuracy of conventional MRI/DWI combinations were 91.7% and 90.7%, respectively. Conventional MRI/DWI combinations revealed a positive predictive value of 97.8% and only 4 false-negative findings. The addition of DWI to conventional MRI considerably improves the sensitivity and accuracy of tumor detection in young patients treated with fertility-sparing surgery, which supports the inclusion quantitative analysis of ADC value in routine MRI protocol before fertility-sparing surgery.

  16. Panoramic images of conventional radiographs: digital panoramic dynamic images

    International Nuclear Information System (INIS)

    Schultze, M.

    2001-01-01

    The benefits of digital technic s to od ontology are evident. Instant images, the possibility to handle them, the reduction of exposition time to radiations, better quality image, better quality information, Stocking them in a compact disc, occupying very little space, allows an easy transport and duplication, as well as the possibility to transfer and save it in an electronica l support.This kind of communication allows the transmission of digital images and every other type of data, instantaneously and no matter distances or geographical borders. Anyway, we should point out that conventional and digital technic s reveal the same information contents

  17. Arthritis: Conventional and Advanced Radiological Imaging

    Directory of Open Access Journals (Sweden)

    Adviye Ergun

    2014-06-01

    Full Text Available Arthritides are acute or chronic inflammation of one or more joints. The most common types of arthritis are osteoarthritis and rheumatoid arthritis, but there are more than 100 different forms. Right and early diagnosis is extremely important for the prevention of eventual structural and functional disability of the affected joint. Imaging findings, especially those of advanced level imaging, play a major role in diagnosis and monitor the progression of arthritis or its response to therapy. The objective of the review is to discuss the findings of conventional and advanced radiological imaging of most common arthritides and to present a simplified approach for their radiological evaluation.

  18. Detection of partial-thickness supraspinatus tendon tears: is a single direct MR arthrography series in ABER position as accurate as conventional MR arthrography?

    International Nuclear Information System (INIS)

    Schreinemachers, Saskia A.; Hulst, Victor P.M. van der; Woude, Henk-Jan van der; Willems, W.J.; Bipat, Shandra

    2009-01-01

    The purpose of this study was to retrospectively evaluate sensitivity and specificity of a single magnetic resonance (MR) arthrography series in abduction external rotation (ABER) position compared with conventional MR arthrography for detection of supraspinatus tendon tears, with arthroscopy as gold standard, and to assess interobserver variability. Institutional review board approval was obtained; informed consent was waived. MR arthrograms of 250 patients (170 men and 80 women; mean age, 36 years) were retrospectively and independently evaluated by three observers. Oblique coronal T1-weighted fat-suppressed images, proton density, and T2-weighted images and axial T1-weighted images and oblique sagittal T1-weighted fat-suppressed images were analyzed to detect supraspinatus tendon tears. Separately, a single T1-weighted fat-suppressed oblique axial series in ABER position was evaluated. Both protocols were scored randomly without knowledge of patients' clinical history and arthroscopy results. Tears were subclassified, based on articular surface integrity and extension (Lee classification). Interobserver agreement was assessed by kappa statistics for all patients. Ninety-two of 250 patients underwent arthroscopy; sensitivity and specificity of ABER and conventional MR arthrography were calculated and compared using paired McNemar test. Weighted kappa values of ABER and conventional MR arthrography were 0.48-0.65 and 0.60-0.67, respectively. According to arthroscopy, 69 of 92 patients had an intact cuff, and 23 patients had a cuff tear (16 partial thickness and seven full thickness). There were no statistically significant differences between ABER and conventional MR arthrography regarding sensitivity (48-61% and 52-70%, respectively) and specificity (80-94% and 91-95%). Sensitivity and specificity of a single T1-weighted series in ABER position and conventional MR arthrography are comparable for assessment of rotator cuff tears. (orig.)

  19. Detection of partial-thickness supraspinatus tendon tears: is a single direct MR arthrography series in ABER position as accurate as conventional MR arthrography?

    Energy Technology Data Exchange (ETDEWEB)

    Schreinemachers, Saskia A. [Onze Lieve Vrouwe Gasthuis, Department of Radiology, Amsterdam (Netherlands); Onze Lieve Vrouwe Gasthuis, Amsterdam (Netherlands); Hulst, Victor P.M. van der; Woude, Henk-Jan van der [Onze Lieve Vrouwe Gasthuis, Department of Radiology, Amsterdam (Netherlands); Willems, W.J. [Onze Lieve Vrouwe Gasthuis, Orthopaedic Surgery, Amsterdam (Netherlands); Bipat, Shandra [University of Amsterdam (NL). Department of Radiology, Academic Medical Center (Netherlands)

    2009-10-15

    The purpose of this study was to retrospectively evaluate sensitivity and specificity of a single magnetic resonance (MR) arthrography series in abduction external rotation (ABER) position compared with conventional MR arthrography for detection of supraspinatus tendon tears, with arthroscopy as gold standard, and to assess interobserver variability. Institutional review board approval was obtained; informed consent was waived. MR arthrograms of 250 patients (170 men and 80 women; mean age, 36 years) were retrospectively and independently evaluated by three observers. Oblique coronal T1-weighted fat-suppressed images, proton density, and T2-weighted images and axial T1-weighted images and oblique sagittal T1-weighted fat-suppressed images were analyzed to detect supraspinatus tendon tears. Separately, a single T1-weighted fat-suppressed oblique axial series in ABER position was evaluated. Both protocols were scored randomly without knowledge of patients' clinical history and arthroscopy results. Tears were subclassified, based on articular surface integrity and extension (Lee classification). Interobserver agreement was assessed by kappa statistics for all patients. Ninety-two of 250 patients underwent arthroscopy; sensitivity and specificity of ABER and conventional MR arthrography were calculated and compared using paired McNemar test. Weighted kappa values of ABER and conventional MR arthrography were 0.48-0.65 and 0.60-0.67, respectively. According to arthroscopy, 69 of 92 patients had an intact cuff, and 23 patients had a cuff tear (16 partial thickness and seven full thickness). There were no statistically significant differences between ABER and conventional MR arthrography regarding sensitivity (48-61% and 52-70%, respectively) and specificity (80-94% and 91-95%). Sensitivity and specificity of a single T1-weighted series in ABER position and conventional MR arthrography are comparable for assessment of rotator cuff tears. (orig.)

  20. Positron range in PET imaging: non-conventional isotopes

    International Nuclear Information System (INIS)

    Jødal, L; Le Loirec, C; Champion, C

    2014-01-01

    In addition to conventional short-lived radionuclides, longer-lived isotopes are becoming increasingly important to positron emission tomography (PET). The longer half-life both allows for circumvention of the in-house production of radionuclides, and expands the spectrum of physiological processes amenable to PET imaging, including processes with prohibitively slow kinetics for investigation with short-lived radiotracers. However, many of these radionuclides emit ‘high-energy’ positrons and gamma rays which affect the spatial resolution and quantitative accuracy of PET images. The objective of the present work is to investigate the positron range distribution for some of these long-lived isotopes. Based on existing Monte Carlo simulations of positron interactions in water, the probability distribution of the line of response displacement have been empirically described by means of analytic displacement functions. Relevant distributions have been derived for the isotopes 22 Na, 52 Mn, 89 Zr, 45 Ti, 51 Mn, 94m Tc, 52m Mn, 38 K, 64 Cu, 86 Y, 124 I, and 120 I. It was found that the distribution functions previously found for a series of conventional isotopes (Jødal et al 2012 Phys. Med. Bio. 57 3931–43), were also applicable to these non-conventional isotopes, except that for 120 I, 124 I, 89 Zr, 52 Mn, and 64 Cu, parameters in the formulae were less well predicted by mean positron energy alone. Both conventional and non-conventional range distributions can be described by relatively simple analytic expressions. The results will be applicable to image-reconstruction software to improve the resolution. (paper)

  1. Image quality characteristics for virtual monoenergetic images using dual-layer spectral detector CT: Comparison with conventional tube-voltage images.

    Science.gov (United States)

    Sakabe, Daisuke; Funama, Yoshinori; Taguchi, Katsuyuki; Nakaura, Takeshi; Utsunomiya, Daisuke; Oda, Seitaro; Kidoh, Masafumi; Nagayama, Yasunori; Yamashita, Yasuyuki

    2018-05-01

    To investigate the image quality characteristics for virtual monoenergetic images compared with conventional tube-voltage image with dual-layer spectral CT (DLCT). Helical scans were performed using a first-generation DLCT scanner, two different sizes of acrylic cylindrical phantoms, and a Catphan phantom. Three different iodine concentrations were inserted into the phantom center. The single-tube voltage for obtaining virtual monoenergetic images was set to 120 or 140 kVp. Conventional 120- and 140-kVp images and virtual monoenergetic images (40-200-keV images) were reconstructed from slice thicknesses of 1.0 mm. The CT number and image noise were measured for each iodine concentration and water on the 120-kVp images and virtual monoenergetic images. The noise power spectrum (NPS) was also calculated. The iodine CT numbers for the iodinated enhancing materials were similar regardless of phantom size and acquisition method. Compared with the iodine CT numbers of the conventional 120-kVp images, those for the monoenergetic 40-, 50-, and 60-keV images increased by approximately 3.0-, 1.9-, and 1.3-fold, respectively. The image noise values for each virtual monoenergetic image were similar (for example, 24.6 HU at 40 keV and 23.3 HU at 200 keV obtained at 120 kVp and 30-cm phantom size). The NPS curves of the 70-keV and 120-kVp images for a 1.0-mm slice thickness over the entire frequency range were similar. Virtual monoenergetic images represent stable image noise over the entire energy spectrum and improved the contrast-to-noise ratio than conventional tube voltage using the dual-layer spectral detector CT. Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  2. Imaging of the digital arteries: Digital subtraction angiography versus conventional angiography

    International Nuclear Information System (INIS)

    Menanteau, B.P.; Treutenaere, J.M.; Marcus, C.; Ladam, V.; Gausserand, F.

    1986-01-01

    The authors report their experience with the use of digital subtraction angiography (DSA) and conventional angiography of the hand. Of the 95 patients in the study group, 80 underwent conventional angiography and 15 underwent DSA. They analyzed the studies with regard to the type and amount of contrast agent used, the number of radiographs needed, and the diagnostic quality of the images. Conventional angiography often requires general anesthesia, magnification, and pharmaco-angiographic techniques to improve the image-based diagnosis. In comparison with conventional angiography, intraarterial DSA is characterized by improved contrast sensitivity and inferior spatial resolution. However, DSA provides images as acceptable as those of conventional angiography. Smaller catheters can be used, and the examination is performed under local anesthesia. The authors conclude that intraarterial DSA is now the technique of choice for examining patients with chronic ischemia of the hand

  3. Diagnostic imaging of Klippel-Feil syndrome: conventional radiography, CT and MR imaging. Case report

    International Nuclear Information System (INIS)

    Jochens, R.; Schubeus, P.; Steinkamp, H.J.; Menzhausen, L.; Felix, R.

    1993-01-01

    In two patients with Klippel-Feil syndrome, type II radiographic findings of the malformation are shown in the cervical spine and the craniocervical junction. Conventional X-rays of the cervical spine in the AP and lateral view and conventional tomography as well as CT of the cervical spine were obtained in both patients. One of the two patients additionally underwent MR imaging. Findings of the different imaging modalities are compared with each other. (orig.) [de

  4. Lateral sesamoid position in hallux valgus: correlation with the conventional radiological assessment.

    Science.gov (United States)

    Agrawal, Yuvraj; Desai, Aravind; Mehta, Jaysheel

    2011-12-01

    We aimed to quantify the severity of the hallux valgus based on the lateral sesamoid position and to establish a correlation of our simple assessment method with the conventional radiological assessments. We reviewed one hundred and twenty two dorso-plantar weight bearing radiographs of feet. The intermetatarsal and hallux valgus angles were measured by the conventional methods; and the position of lateral sesamoid in relation to first metatarsal neck was assessed by our new and simple method. Significant correlation was noted between intermetatarsal angle and lateral sesamoid position (Rho 0.74, p lateral sesamoid position and hallux valgus angle (Rho 0.56, p lateral sesamoid position is simple, less time consuming and has statistically significant correlation with that of the established conventional radiological measurements. Copyright © 2011 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  5. Image quality in conventional chest radiography. Evaluation using the postprocessing tool Diamond View

    International Nuclear Information System (INIS)

    Niemann, Tilo; Reisinger, Clemens; Rau, Philipp; Schwarz, Jochen; Ruis-Lopez, Laura; Bongartz, Georg

    2010-01-01

    The objective of this work was to evaluate the influence of the postprocessing tool Diamond View (Siemens AG Medical Solutions, Germany) on image quality in conventional chest radiography. Evaluation of image quality remains a challenge in conventional radiography. Based on the European Commission quality criteria we evaluated the improvement of image quality when applying the new postprocessing tool Diamond View (Siemens AG Medical solutions, Germany) to conventional chest radiographs. Three different readers prospectively evaluated 102 digital image pairs of chest radiographs. Statistical analysis was performed with a p value <0.05 considered as significant. Images were evaluated on basis of the modified imaging Quality Criteria by the Commission of the European Communities. Each of the 11 image quality criteria was evaluated separately using a five point classification. Statistical analysis showed an overall tendency for improved image quality for Diamond View (DV) for all criteria. Significant differences could be found in most of the criteria. In conclusion DV improves image quality in conventional chest radiographs.

  6. Preoperative conventional magnetic resonance images versus magnetic resonance arthrography of subacromial impingement syndrome

    International Nuclear Information System (INIS)

    Ahn, Sang Hyuk; Park, Jung Hwan; Moon, Tae Yong; Lee, In Sook; Lee, Seung Jun

    2012-01-01

    To evaluate the usefulness of conventional magnetic resonance images (MRI) for arthroscopic surgery in subacromial impingement syndrome of the shoulder, as an alternative to MR arthrography with additional T2 fat saturation images (MRA). The preoperative MRI of 77 patients (45 females, 32 males) (52 right, 25 left) and MRA of 34 patients (14 females, 20 males) (24 right, 10 left) with subsequent arthroscopic confirmation of subacromial impingement syndrome were reviewed retrospectively. The lesions requiring arthroscopic surgery were 95 subacromial spurs, 101 subacromial bursitis, and 51 full-thickness and 44 partial thickness tears of the supraspinatus among 111 cases for both studies. A two by two table was constructed in order to calculate the sensitivity and specificity of both studies against arthroscopic outcomes. Also we analyzed the false positive and false negative cases of the full-thickness tears individually. The detection rates of subacromial spur and bursitis and full and partial thickness tears of the supraspinatus were 91%, 94%, 77%, and 65% in MRI and 93%, 100%, 83%, and 77% in MRA respectively. Their specificities were 33%, 33%, 90%, and 76% in MRI and 50%, 75%, 100%, and 71% in MRA respectively. Eleven false negative cases in regards to MRI resulted in Ellman's grade 3 partial thickness tear (72.7%), mild bursitis (63.6%), greater tuberosity erosion (45.5%), and negative fluid signal of the glenohumeral joint (81.8%). Three false positive cases on the MRI were induced from errors with lower window depth and width on the imagings. Two false negative cases on MRA were induced from the adhesion between Ellman's grade 3 rim rent tear and the glenohumeral joint cavity. Conventional MR images could be used to decide the arthroscopic surgery in subacromial impingement syndrome, as an alternative to MR arthrography with additional T2 fat saturation images

  7. Preoperative conventional magnetic resonance images versus magnetic resonance arthrography of subacromial impingement syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Sang Hyuk; Park, Jung Hwan; Moon, Tae Yong [Pusan National Univ. Yangsan Hospital, Yangsan (Korea, Republic of); Lee, In Sook; Lee, Seung Jun [Pusan National Univ. Hospital, Busan (Korea, Republic of)

    2012-09-15

    To evaluate the usefulness of conventional magnetic resonance images (MRI) for arthroscopic surgery in subacromial impingement syndrome of the shoulder, as an alternative to MR arthrography with additional T2 fat saturation images (MRA). The preoperative MRI of 77 patients (45 females, 32 males) (52 right, 25 left) and MRA of 34 patients (14 females, 20 males) (24 right, 10 left) with subsequent arthroscopic confirmation of subacromial impingement syndrome were reviewed retrospectively. The lesions requiring arthroscopic surgery were 95 subacromial spurs, 101 subacromial bursitis, and 51 full-thickness and 44 partial thickness tears of the supraspinatus among 111 cases for both studies. A two by two table was constructed in order to calculate the sensitivity and specificity of both studies against arthroscopic outcomes. Also we analyzed the false positive and false negative cases of the full-thickness tears individually. The detection rates of subacromial spur and bursitis and full and partial thickness tears of the supraspinatus were 91%, 94%, 77%, and 65% in MRI and 93%, 100%, 83%, and 77% in MRA respectively. Their specificities were 33%, 33%, 90%, and 76% in MRI and 50%, 75%, 100%, and 71% in MRA respectively. Eleven false negative cases in regards to MRI resulted in Ellman's grade 3 partial thickness tear (72.7%), mild bursitis (63.6%), greater tuberosity erosion (45.5%), and negative fluid signal of the glenohumeral joint (81.8%). Three false positive cases on the MRI were induced from errors with lower window depth and width on the imagings. Two false negative cases on MRA were induced from the adhesion between Ellman's grade 3 rim rent tear and the glenohumeral joint cavity. Conventional MR images could be used to decide the arthroscopic surgery in subacromial impingement syndrome, as an alternative to MR arthrography with additional T2 fat saturation images.

  8. Imaging in hematology. Part 1: Ultrasonography and conventional radiology

    International Nuclear Information System (INIS)

    Zhechev, Y.

    2003-01-01

    Applications of conventional ultrasonography techniques (B-mode or real time) in oncohematology are presented. The newer adaptations (in particular colour Doppler) provide incremental advantages that support their inclusion in the imaging techniques available to modern hematology. Conventional radiologic studies include chest and bone X-ray, gastrointestinal contrast examination and bipedal lymphangiography

  9. Large-field image intensifiers versus conventional chest radiography: ROC study with simulated interstitial disease

    International Nuclear Information System (INIS)

    Winter, L.H.L.; Chakraborty, D.P.; Waes, P.F.G.M.

    1988-01-01

    Two image intensifier tubes have recently been introduced whose large imaging area makes them suitable for chest imaging (Phillips Pulmodiagnost TLX slit II and Siemens TX 57 large entrance field II). Both modalities present a 10 x 10-cm hard copy image to the radiologist. A receiver operating characteristic (ROC) curve study with simulated interstitial disease was performed to compare the image quality of these image intensifiers with conventional chest images. The relative ranking in terms of decreasing ROC areas was Siemens, conventional, and Philips. Compared with conventional imaging, none of the differences in ROC curve area were statistically significant at the 5% level

  10. Optimization of conventional X-ray images for the detection of hook of hamate fractures

    International Nuclear Information System (INIS)

    Andresen, R.; Adam, C.; Radmer, S.; Scheufler, O.; Bogusch, G.

    2006-01-01

    Fractures of the hook of the hamate are a rare event. The fracture cannot always be detected clinically and standard radiographs do not always provide an overlap-free image of the hook of the hamate, so that fractures can easily be overlooked. The objective of the present study was to examine if the sensitivity of detecting hamulus ossis hamati fractures can further be improved by a modified conventional radiographic projection. After dissection of the hook of the hamate on 10 cadaver hands, a fracture was produced close to the base using a surgical chisel. Conventional radiographs were then performed in four different projections (dorso-palmar, lateral, carpal-tunnel and oblique view). The oblique view was obtained in a 45 supination position, slight extension and radial duction, with the tube tilted from distal to proximal by 30 . An axial spiral CT was used as a reference for detection of the fracture. The highest sensitivity of the conventional radiographs, with 8/10 identified fractures (80%), was achieved by the oblique view. The carpal-tunnel view with 4/10 (40%) and the dorso-palmar projection with 3/10 (30%) were much lower. All fractures were missed in the lateral projection. If all of the conventional radiographic projections are taken into account, the sensitivity is increased to 90%. All of the fractures were reliably detected in the axial CT-image. If a hamulus ossis hamati fracture is suspected clinically, in addition to the dorso-palmar and carpal-tunnel view, the special oblique view described here should be performed as a third projection plane, while the lateral view can be dispensed with. However, even if all projections are taken into account, a negative finding in the conventional radiographic imaging does not exclude a fracture with absolute certainty. In such cases, a CT or MRI should be performed to exclude a fracture. (orig.)

  11. Forming positive-negative images using conditioned partial measurements from reference arm in ghost imaging.

    Science.gov (United States)

    Wen, Jianming

    2012-09-01

    A recent thermal ghost imaging experiment implemented in Wu's group [Chin. Phys. Lett. 279, 074216 (2012)] showed that both positive and negative images can be constructed by applying a novel algorithm. This algorithm allows us to form the images with the use of partial measurements from the reference arm (even which never passes through the object), conditioned on the object arm. In this paper, we present a simple theory that explains the experimental observation and provides an in-depth understanding of conventional ghost imaging. In particular, we theoretically show that the visibility of formed images through such an algorithm is not bounded by the standard value 1/3. In fact, it can ideally grow up to unity (with reduced imaging quality). Thus, the algorithm described here not only offers an alternative way to decode spatial correlation of thermal light, but also mimics a "bandpass filter" to remove the constant background such that the visibility or imaging contrast is improved. We further show that conditioned on one still object present in the test arm, it is possible to construct the object's image by sampling the available reference data.

  12. Is a single direct MR arthrography series in ABER position as accurate in detecting anteroinferior labroligamentous lesions as conventional MR arthography?

    Energy Technology Data Exchange (ETDEWEB)

    Schreinemachers, Saskia A.; Hulst, Victor P.M. van der; Woude, Henk-Jan van der [Onze Lieve Vrouwe Gasthuis, Department of Radiology, Amsterdam (Netherlands); Jaap Willems, W. [Onze Lieve Vrouwe Gasthuis, Orthopaedic Surgery, Amsterdam (Netherlands); Bipat, Shandra [University of Amsterdam, Department of Radiology, Academic Medical Centre, Amsterdam (Netherlands)

    2009-07-15

    The purpose of this study is to retrospectively compare accuracy of single magnetic resonance (MR) arthrography series in Abduction External Rotation (ABER) with conventional MR arthrography for detection and characterisation of anteroinferior labroligamentous lesions, with arthroscopy as reference standard. Inter-observer variability of both protocols was determined. Institutional review board approval was obtained; informed consent was waived. MR arthrograms, including oblique axial fat suppressed T1-weighted images in ABER position and conventional imaging directions of 250 patients (170 men, 80 women; mean age, 36 years), were retrospectively and independently evaluated by three reviewers. Reviewers were blinded to clinical information and arthroscopic results. Labroligamentous lesions were registered in both ABER and MRa. The lesions were sub-classified (Bankart, Perthes, anterior labrum periosteal sleeve avulsion (ALPSA) or lesions not otherwise specified). Inter-observer agreement was assessed by Kappa statistics for all 250 patients. Ninety-two of 250 patients underwent arthroscopy. Sensitivity, specificity and accuracy of ABER versus conventional MR arthrography were calculated and compared using paired McNemar test. Kappa values of the ABER and conventional MR arthrography ranged from 0.44 to 0.56 and 0.44 to 0.62, respectively. According to arthroscopy, 45 of 92 patients had an intact anteroinferior labrum, and in 44 patients, a labroligamentous lesion (eight Bankart, seven Perthes, 29 ALPSA and three lesions not otherwise specified) was diagnosed. There were no statistically significant differences between ABER and conventional MR arthrography regarding sensitivity (85-89%, 89-96%), specificity (82-91%, 84-89%) and overall accuracy (50-62%, 53-63%). The results of a single MR arthrography series in ABER position are comparable with those of conventional MR arthrography for detecting anteroinferior labroligamentous lesions. (orig.)

  13. Comparison of prostate contours between conventional stepping transverse imaging and Twister-based sagittal imaging in permanent interstitial prostate brachytherapy.

    Science.gov (United States)

    Kawakami, Shogo; Ishiyama, Hiromichi; Satoh, Takefumi; Tsumura, Hideyasu; Sekiguchi, Akane; Takenaka, Kouji; Tabata, Ken-Ichi; Iwamura, Masatsugu; Hayakawa, Kazushige

    2017-08-01

    To compare prostate contours on conventional stepping transverse image acquisitions with those on twister-based sagittal image acquisitions. Twenty prostate cancer patients who were planned to have permanent interstitial prostate brachytherapy were prospectively accrued. A transrectal ultrasonography probe was inserted, with the patient in lithotomy position. Transverse images were obtained with stepping movement of the transverse transducer. In the same patient, sagittal images were also obtained through rotation of the sagittal transducer using the "Twister" mode. The differences of prostate size among the two types of image acquisitions were compared. The relationships among the difference of the two types of image acquisitions, dose-volume histogram (DVH) parameters on the post-implant computed tomography (CT) analysis, as well as other factors were analyzed. The sagittal image acquisitions showed a larger prostate size compared to the transverse image acquisitions especially in the anterior-posterior (AP) direction ( p transverse image acquisitions was correlated to DVH parameters such as D 90 ( R = 0.518, p = 0.019), and V 100 ( R = 0.598, p = 0.005). There were small but significant differences in the prostate contours between the transverse and the sagittal planning image acquisitions. Furthermore, our study suggested that the differences between the two types of image acquisitions might correlated to dosimetric results on CT analysis.

  14. Postcontrast T1-weighted brain magnetic resonance imaging in pediatric patients: comparison between postcontrast fat-suppression imaging and conventional T1-weighted or magnetization transfer imaging

    International Nuclear Information System (INIS)

    Lee, Choong Wook; Goo, Hyun Woo

    2004-01-01

    We wished to assess the merits and weaknesses of postcontrast fat-suppression (FS) brain MR imaging in children for the evaluation of various enhancing lesions as compared with postcontrast conventional T1-weighted or magnetization transfer (MT) imaging. We reviewed the records of those patients with enhancing lesions on brain MR imaging who had undergone both FS imaging and one of the conventional T1-weighted or MT imaging as a post-contrast T1-weighted brain MR imaging. Thirty-one patients (21 male, 10 female; mean age, 8.7 years) with 38 enhancing lesions (18 intra-axial, 16 extra-axial and 4 orbital locations) were included in this study. There were 27 pairs of FS and conventional imagings, and 13 pairs of FS and MT imagings available for evaluation. Two radiologists visually assessed by consensus the lesions' conspicuity, and they also looked for the presence of flow or susceptibility artifacts in a total of 40 pairs of MR imagings. For 19 measurable lesions (14 pairs of FS and conventional T1-weighted imagings, 5 pairs of FS and MT imagings), the contrast ratios between the lesion and the normal brain ([SIlesion-SIwater]/[SInormal brain-SIwater]) were calculated and compared. Compared with conventional imaging, the lesion conspicuity on FS imaging was better in 10 cases (7 extra-axial lesions, 2 orbital lesions and 1 fat-containing intra-axial lesion), equal in 16 cases, and worse in one case. Compared with MT imaging, the lesion conspicuity on FS imaging was better in 3 cases (2 extra-axial lesions and 1 intra-axial lesion), equal in 8 cases, and worse in 2 cases. Image quality of FS imaging was compromised by flow or susceptibility artifacts for 7 patients. The contrast ratios for FS imaging were not significantly different from those for conventional imaging (2.2±0.7 vs. 2.2±0.6, respectively, p=0.914) and they were significantly lower than those for MT imaging (2.4±0.8 vs. 4.5±1.5, respectively, p=0.018). Postcontrast FS brain MR imaging appears to be

  15. Two-dimensional intraventricular flow mapping by digital processing conventional color-Doppler echocardiography images.

    Science.gov (United States)

    Garcia, Damien; Del Alamo, Juan C; Tanne, David; Yotti, Raquel; Cortina, Cristina; Bertrand, Eric; Antoranz, José Carlos; Perez-David, Esther; Rieu, Régis; Fernandez-Aviles, Francisco; Bermejo, Javier

    2010-10-01

    Doppler echocardiography remains the most extended clinical modality for the evaluation of left ventricular (LV) function. Current Doppler ultrasound methods, however, are limited to the representation of a single flow velocity component. We thus developed a novel technique to construct 2D time-resolved (2D+t) LV velocity fields from conventional transthoracic clinical acquisitions. Combining color-Doppler velocities with LV wall positions, the cross-beam blood velocities were calculated using the continuity equation under a planar flow assumption. To validate the algorithm, 2D Doppler flow mapping and laser particle image velocimetry (PIV) measurements were carried out in an atrio-ventricular duplicator. Phase-contrast magnetic resonance (MR) acquisitions were used to measure in vivo the error due to the 2D flow assumption and to potential scan-plane misalignment. Finally, the applicability of the Doppler technique was tested in the clinical setting. In vitro experiments demonstrated that the new method yields an accurate quantitative description of the main vortex that forms during the cardiac cycle (mean error for vortex radius, position and circulation). MR image analysis evidenced that the error due to the planar flow assumption is close to 15% and does not preclude the characterization of major vortex properties neither in the normal nor in the dilated LV. These results are yet to be confirmed by a head-to-head clinical validation study. Clinical Doppler studies showed that the method is readily applicable and that a single large anterograde vortex develops in the healthy ventricle while supplementary retrograde swirling structures may appear in the diseased heart. The proposed echocardiographic method based on the continuity equation is fast, clinically-compliant and does not require complex training. This technique will potentially enable investigators to study of additional quantitative aspects of intraventricular flow dynamics in the clinical setting by

  16. Near infrared hyperspectral imaging of blends of conventional and waxy hard wheats

    Directory of Open Access Journals (Sweden)

    Stephen R. Delwiche

    2018-02-01

    Full Text Available Recent development of hard winter waxy (amylose-free wheat adapted to the North American climate has prompted the quest to find a rapid method that will determine mixture levels of conventional wheat in lots of identity preserved waxy wheat. Previous work documented the use of conventional near infrared (NIR reflectance spectroscopy to determine the mixture level of conventional wheat in waxy wheat, with an examined range, through binary sample mixture preparation, of 0–100% (weight conventional / weight total. The current study examines the ability of NIR hyperspectral imaging of intact kernels to determine mixture levels. Twenty-nine mixtures (0, 1, 2, 3, 4, 5, 10, 15, …, 95, 96, 97, 98, 99, 100% were formed from known genotypes of waxy and conventional wheat. Two-class partial least squares discriminant analysis (PLSDA and statistical pattern recognition classifier models were developed for identifying each kernel in the images as conventional or waxy. Along with these approaches, conventional PLS1 regression modelling was performed on means of kernel spectra within each mixture test sample. Results indicated close agreement between all three approaches, with standard errors of prediction for the better preprocess transformations (PLSDA models or better classifiers (pattern recognition models of approximately 9 percentage units. Although such error rates were slightly greater than ones previously published using non-imaging NIR analysis of bulk whole kernel wheat and wheat meal, the HSI technique offers an advantage of its potential use in sorting operations.

  17. Future directions for positive body image research.

    Science.gov (United States)

    Halliwell, Emma

    2015-06-01

    The emergence of positive body image research during the last 10 years represents an important shift in the body image literature. The existing evidence provides a strong empirical basis for the study of positive body image and research has begun to address issues of age, gender, ethnicity, culture, development, and intervention in relation to positive body image. This article briefly reviews the existing evidence before outlining directions for future research. Specifically, six areas for future positive body image research are outlined: (a) conceptualization, (b) models, (c) developmental factors, (d) social interactions, (e) cognitive processing style, and (f) interventions. Finally, the potential role of positive body image as a protective factor within the broader body image literature is discussed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Seismic reflection imaging with conventional and unconventional sources

    Science.gov (United States)

    Quiros Ugalde, Diego Alonso

    This manuscript reports the results of research using both conventional and unconventional energy sources as well as conventional and unconventional analysis to image crustal structure using reflected seismic waves. The work presented here includes the use of explosions to investigate the Taiwanese lithosphere, the use of 'noise' from railroads to investigate the shallow subsurface of the Rio Grande rift, and the use of microearthquakes to image subsurface structure near an active fault zone within the Appalachian mountains. Chapter 1 uses recordings from the land refraction and wide-angle reflection component of the Taiwan Integrated Geodynamic Research (TAIGER) project. The most prominent reflection feature imaged by these surveys is an anomalously strong reflector found in northeastern Taiwan. The goal of this chapter is to analyze the TAIGER recordings and to place the reflector into a geologic framework that fits with the modern tectonic kinematics of the region. Chapter 2 uses railroad traffic as a source for reflection profiling within the Rio Grande rift. Here the railroad recordings are treated in an analogous way to Vibroseis recordings. These results suggest that railroad noise in general can be a valuable new tool in imaging and characterizing the shallow subsurface in environmental and geotechnical studies. In chapters 3 and 4, earthquakes serve as the seismic imaging source. In these studies the methodology of Vertical Seismic Profiling (VSP) is borrowed from the oil and gas industry to develop reflection images. In chapter 3, a single earthquake is used to probe a small area beneath Waterboro, Maine. In chapter 4, the same method is applied to multiple earthquakes to take advantage of the increased redundancy that results from multiple events illuminating the same structure. The latter study demonstrates how dense arrays can be a powerful new tool for delineating, and monitoring temporal changes of deep structure in areas characterized by significant

  19. Issues in identifying germ tube positive yeasts by conventional methods.

    Science.gov (United States)

    Yazdanpanah, Atta; Khaithir, Tzar Mohd Nizam

    2014-01-01

    Candida speciation is vital for epidemiology and management of candidiasis. Nonmolecular conventional methods often fail to identify closely related germ tube positive yeasts from clinical specimens. The present study was conducted to identify these yeasts and to highlight issues in conventional versus molecular methods of identification. A total of 98 germ tube positive yeasts from high vaginal swabs were studied over a 12-month period. Isolates were examined with various methods including growth at 42 °C and 45 °C on Sabouraud dextrose agar (SDA), color development on CHROMagar Candida medium, chlamydospore production on corn meal agar at 25 °C, carbohydrate assimilation using ID 32C system, and polymerase chain reaction using a single pair of primers targeting the hyphal wall protein 1 (Hwp1) gene. Of all the isolates studied, 97 were molecularly confirmed as C. albicans and one isolate was identified as C. dubliniensis. No C. africana was detected in this study. The molecular method used in our study was an accurate and useful tool for discriminating C. albicans, C. dubliniensis, and C. africana. The conventional methods, however, were less accurate and riddled with many issues that will be discussed in further details. © 2013 Wiley Periodicals, Inc.

  20. Imaging method of brain surface anatomy structures using conventional T2-weighted MR images

    International Nuclear Information System (INIS)

    Hatanaka, Masahiko; Machida, Yoshio; Yoshida, Tadatoki; Katada, Kazuhiro.

    1992-01-01

    As a non-invasive technique for visualizing the brain surface structure by MRI, surface anatomy scanning (SAS) and the multislice SAS methods have been developed. Both techniques require additional MRI scanning to obtain images for the brain surface. In this paper, we report an alternative method to obtain the brain surface image using conventional T2-weighted multislice images without any additional scanning. The power calculation of the image pixel values, which is incorporated in the routine processing, has been applied in order to enhance the cerebrospinal fluid (CSF) contrast. We think that this method is one of practical approaches for imaging the surface anatomy of the brain. (author)

  1. Comparison study among conventional, tissue harmonic and pulse inversion harmonic images to evaluate pleural effusion and ascites

    International Nuclear Information System (INIS)

    Chung, Hwan Hoon; Kim, Yun Hwan; Kang, Chang Ho; Park, Bum Jin; Chung, Kyoo Byung; Suh, Won Hyuck

    2000-01-01

    To determine the most useful sonographic technique to evaluate pleural effusion and ascites by comparing conventional, tissue harmonic and pulse inversion harmonic images. 12 patients having pleural effusion and 14 patients having ascites were included in this study. 18 patients were male and 8 patients were female. Average age was 54.8 yrs (25-77). We compared images which had been taken at the same section with 3 above mentioned sonographic techniques. Evaluation was done by 3 radiologists in consensus and grades were given to 3 techniques from 1 to 3. Evaluating points were 1) normal structures that border the fluid such as liver, peritoneal lining, pleura, 2) septation in fluid, 3) debris floating in fluid, and 4) artifacts. Pulse inversion harmonic image was the best in image quality for normal structures, followed by tissue harmonic and conventional image (p<0.05). Pulse inversion harmonic image was better than conventional image to evaluate septation in fluid (p<0.05), but there were no statistically significant difference between pulse inversion and tissue harmonic images, and tissue harmonic and conventional images. Tissue harmonic image was better than pulse inversion harmonic and conventional images to evaluate debris floating in fluid (p<0.05) but there was no statistically significant difference between these two latter techniques. Artifacts were most prominent on conventional image followed by tissue harmonic and pulse inversion harmonic image (p<0.05). Pulse inversion harmonic image was the best sonographic technique to evaluate pleural effusion or ascites, However, Tissue harmonic image was the best for evaluation of debris.

  2. Comparison study among conventional, tissue harmonic and pulse inversion harmonic images to evaluate pleural effusion and ascites

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Hwan Hoon; Kim, Yun Hwan; Kang, Chang Ho; Park, Bum Jin; Chung, Kyoo Byung; Suh, Won Hyuck [Korea University College of Medicine, Seoul (Korea, Republic of)

    2000-12-15

    To determine the most useful sonographic technique to evaluate pleural effusion and ascites by comparing conventional, tissue harmonic and pulse inversion harmonic images. 12 patients having pleural effusion and 14 patients having ascites were included in this study. 18 patients were male and 8 patients were female. Average age was 54.8 yrs (25-77). We compared images which had been taken at the same section with 3 above mentioned sonographic techniques. Evaluation was done by 3 radiologists in consensus and grades were given to 3 techniques from 1 to 3. Evaluating points were 1) normal structures that border the fluid such as liver, peritoneal lining, pleura, 2) septation in fluid, 3) debris floating in fluid, and 4) artifacts. Pulse inversion harmonic image was the best in image quality for normal structures, followed by tissue harmonic and conventional image (p<0.05). Pulse inversion harmonic image was better than conventional image to evaluate septation in fluid (p<0.05), but there were no statistically significant difference between pulse inversion and tissue harmonic images, and tissue harmonic and conventional images. Tissue harmonic image was better than pulse inversion harmonic and conventional images to evaluate debris floating in fluid (p<0.05) but there was no statistically significant difference between these two latter techniques. Artifacts were most prominent on conventional image followed by tissue harmonic and pulse inversion harmonic image (p<0.05). Pulse inversion harmonic image was the best sonographic technique to evaluate pleural effusion or ascites, However, Tissue harmonic image was the best for evaluation of debris.

  3. Malignant fibrous histiocytoma of bone: conventional X-ray and MR imaging features

    International Nuclear Information System (INIS)

    Link, T.M.; Haeussler, M.D.; Poppek, S.; Woertler, K.; Rummeny, E.J.; Blasius, S.; Lindner, N.

    1998-01-01

    Objective. To evaluate the conventional X-ray and MR imaging features of malignant fibrous histiocytoma (MFH) of bone. Design. MRI examinations and conventional radiographs were reviewed in 39 patients with biopsy-proven MFH. Imaging characteristics were analyzed and the differential diagnoses assessed in a masked fashion by two experienced radiologists. Results. Typical X-ray features included aggressive, destructive tumor growth centrally located in the metaphysis of long bones. Periosteal reactions and expansive growth were rarely seen. On MR images extraosseous tumor spread was frequently noted. On T2-weighted images and contrast-enhanced T1-weighted images most of the tumors displayed an inhomogeneous, nodular signal pattern with peripheral Gd-DTPA enhancement. Conclusions. Although several MR imaging criteria were typical for MFH none of them was specific. X-ray diagnosis of MFH may also prove difficult, with the main differential diagnosis being metastasis in the older and osteosarcoma in the younger population. (orig.)

  4. Comparison of peritoneal tumor imaging using conventional MR imaging and diffusion-weighted MR imaging with different b values

    Energy Technology Data Exchange (ETDEWEB)

    Bozkurt, Mahmut [Buhara Private Hospital Department of Radiology, Erzurum (Turkey); Doganay, Selim [Erciyes University, School of Medicine, Department of Radiology, Kayseri (Turkey); Kantarci, Mecit, E-mail: akkanrad@hotmail.com [Atatuerk University, School of Medicine, Department of Radiology, Erzurum (Turkey); Yalcin, Ahmet; Eren, Suat [Atatuerk University, School of Medicine, Department of Radiology, Erzurum (Turkey); Atamanalp, S. Selcuk [Atatuerk University, School of Medicine, Department of General Surgery, Erzurum (Turkey); Yuce, Ihsan [Atatuerk University, School of Medicine, Department of Radiology, Erzurum (Turkey); Yildirgan, M. Ilhan [Atatuerk University, School of Medicine, Department of General Surgery, Erzurum (Turkey)

    2011-11-15

    Purpose: The aim of this study was to evaluate the utility of DW MRI with two different b values in identifying peritoneal tumors in oncology patients. Materials and methods: Nineteen patients with known malignancy underwent abdominal and pelvic MRI before surgery. MRI included free-breathing DWI with b values of 400 and 800 s/mm{sup 2}, T1-weighted fat-suppressed spoiled gradient-echo, T2-weighted fat-saturated turbo spin-echo, and 5-min delayed gadolinium-enhanced imaging. Two observers reviewed images for peritoneal tumors at ten anatomic sites within consensus. The results of laparatomy and histopathological evaluation were compared with MRI results. Sensitivity, specificity, and accuracy of identifying peritoneal metastases were calculated for conventional MRI, combined DWI with a b value of 400 s/mm{sup 2} and conventional MRI, and combined DWI with a b value of 800 s/mm{sup 2} and conventional MRI by consensus of two observers. Results: One-hundred and twenty-five peritoneal metastasis sites were confirmed by surgical and histopathological findings. Conventional MRI alone identified 72 peritoneal metastases (sensitivity, 0.58; specificity, 0.87; accuracy, 0.67). Combined DWI with a b value of 400 s/mm{sup 2} and conventional MRI revealed 106 peritoneal metastases (sensitivity, 0.85; specificity, 0.88; accuracy, 0.85). Finally, combined DWI with a b value of 800 s/mm{sup 2} and conventional MRI revealed 103 peritoneal metastases (sensitivity, 0.83; specificity, 0.94; accuracy, 0.86). Conclusion: DWI with a high b value provides complementary information that can improve the detection of peritoneal tumors when combined with conventional MRI. We recommend combined MRI and DWI with a high b value for increasing the sensitivity and accuracy of the preoperative detection of peritoneal tumors.

  5. Comparison of peritoneal tumor imaging using conventional MR imaging and diffusion-weighted MR imaging with different b values

    International Nuclear Information System (INIS)

    Bozkurt, Mahmut; Doganay, Selim; Kantarci, Mecit; Yalcin, Ahmet; Eren, Suat; Atamanalp, S. Selcuk; Yuce, Ihsan; Yildirgan, M. Ilhan

    2011-01-01

    Purpose: The aim of this study was to evaluate the utility of DW MRI with two different b values in identifying peritoneal tumors in oncology patients. Materials and methods: Nineteen patients with known malignancy underwent abdominal and pelvic MRI before surgery. MRI included free-breathing DWI with b values of 400 and 800 s/mm 2 , T1-weighted fat-suppressed spoiled gradient-echo, T2-weighted fat-saturated turbo spin-echo, and 5-min delayed gadolinium-enhanced imaging. Two observers reviewed images for peritoneal tumors at ten anatomic sites within consensus. The results of laparatomy and histopathological evaluation were compared with MRI results. Sensitivity, specificity, and accuracy of identifying peritoneal metastases were calculated for conventional MRI, combined DWI with a b value of 400 s/mm 2 and conventional MRI, and combined DWI with a b value of 800 s/mm 2 and conventional MRI by consensus of two observers. Results: One-hundred and twenty-five peritoneal metastasis sites were confirmed by surgical and histopathological findings. Conventional MRI alone identified 72 peritoneal metastases (sensitivity, 0.58; specificity, 0.87; accuracy, 0.67). Combined DWI with a b value of 400 s/mm 2 and conventional MRI revealed 106 peritoneal metastases (sensitivity, 0.85; specificity, 0.88; accuracy, 0.85). Finally, combined DWI with a b value of 800 s/mm 2 and conventional MRI revealed 103 peritoneal metastases (sensitivity, 0.83; specificity, 0.94; accuracy, 0.86). Conclusion: DWI with a high b value provides complementary information that can improve the detection of peritoneal tumors when combined with conventional MRI. We recommend combined MRI and DWI with a high b value for increasing the sensitivity and accuracy of the preoperative detection of peritoneal tumors.

  6. Future directions for positive body image research

    OpenAIRE

    Halliwell, E.

    2015-01-01

    The emergence of positive body image research during the last 10 years represents an important shift in the body image literature. The existing evidence provides a strong empirical basis for the study of positive body image and research has begun to address issues of age, gender, ethnicity, culture, development, and intervention in relation to positive body image. This article briefly reviews the existing evidence before outlining directions for future research. Specifically, six areas for fu...

  7. Geometry Processing of Conventionally Produced Mouse Brain Slice Images.

    Science.gov (United States)

    Agarwal, Nitin; Xu, Xiangmin; Gopi, M

    2018-04-21

    Brain mapping research in most neuroanatomical laboratories relies on conventional processing techniques, which often introduce histological artifacts such as tissue tears and tissue loss. In this paper we present techniques and algorithms for automatic registration and 3D reconstruction of conventionally produced mouse brain slices in a standardized atlas space. This is achieved first by constructing a virtual 3D mouse brain model from annotated slices of Allen Reference Atlas (ARA). Virtual re-slicing of the reconstructed model generates ARA-based slice images corresponding to the microscopic images of histological brain sections. These image pairs are aligned using a geometric approach through contour images. Histological artifacts in the microscopic images are detected and removed using Constrained Delaunay Triangulation before performing global alignment. Finally, non-linear registration is performed by solving Laplace's equation with Dirichlet boundary conditions. Our methods provide significant improvements over previously reported registration techniques for the tested slices in 3D space, especially on slices with significant histological artifacts. Further, as one of the application we count the number of neurons in various anatomical regions using a dataset of 51 microscopic slices from a single mouse brain. To the best of our knowledge the presented work is the first that automatically registers both clean as well as highly damaged high-resolutions histological slices of mouse brain to a 3D annotated reference atlas space. This work represents a significant contribution to this subfield of neuroscience as it provides tools to neuroanatomist for analyzing and processing histological data. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Direct imaging of phase objects enables conventional deconvolution in bright field light microscopy.

    Directory of Open Access Journals (Sweden)

    Carmen Noemí Hernández Candia

    Full Text Available In transmitted optical microscopy, absorption structure and phase structure of the specimen determine the three-dimensional intensity distribution of the image. The elementary impulse responses of the bright field microscope therefore consist of separate absorptive and phase components, precluding general application of linear, conventional deconvolution processing methods to improve image contrast and resolution. However, conventional deconvolution can be applied in the case of pure phase (or pure absorptive objects if the corresponding phase (or absorptive impulse responses of the microscope are known. In this work, we present direct measurements of the phase point- and line-spread functions of a high-aperture microscope operating in transmitted bright field. Polystyrene nanoparticles and microtubules (biological polymer filaments serve as the pure phase point and line objects, respectively, that are imaged with high contrast and low noise using standard microscopy plus digital image processing. Our experimental results agree with a proposed model for the response functions, and confirm previous theoretical predictions. Finally, we use the measured phase point-spread function to apply conventional deconvolution on the bright field images of living, unstained bacteria, resulting in improved definition of cell boundaries and sub-cellular features. These developments demonstrate practical application of standard restoration methods to improve imaging of phase objects such as cells in transmitted light microscopy.

  9. Arterial hyperintensity on BLADE fluid-attenuated inversion recovery images (FLAIR) in hyperacute territorial infarction: comparison with conventional FLAIR

    Energy Technology Data Exchange (ETDEWEB)

    Kwag, Eujean; Lim, Soo Mee; Park, Ji Eun; Chae, In Hye [Ewha Womans University School of Medicine, Department of Radiology, Mokdong Hospital, Seoul (Korea, Republic of)

    2014-09-15

    To evaluate the utility of BLADE fluid-attenuated inversion recovery images (FLAIR) magnetic resonance (MR) imaging compared to conventional FLAIR for the detection of arterial hyperintensity (AH) in hyperacute territorial infarction. We retrospectively analysed MR images of patients with hyperacute (<6 h) territorial infarction over a 9-month study period. Special attention was paid to the presence or absence of AH in the frontal, parietal and temporal lobes and the number of AHs in the sylvian fissure. We also evaluated the presence of three kinds of artefacts on BLADE FLAIR and conventional FLAIR images. AH was seen in 41 (91 %) patients with conventional FLAIR and 45 (100 %) patients with BLADE FLAIR images. More instances of AH were detected in the frontal, parietal and temporal lobes and within the sylvian fissure using BLADE FLAIR. Motion artefacts, pulsation artefacts from the sigmoid sinus and incomplete cerebrospinal fluid (CSF) nulling that reduced image quality were observed more frequently on conventional FLAIR images than on BLADE FLAIR images. BLADE FLAIR sequences are more sensitive than conventional FLAIR for the detection of AH in hyperacute territorial infarctions and provide better image quality by reducing artefacts. They may be used in place of conventional FLAIR for patients with hyperacute stroke. (orig.)

  10. Noise and analyzer-crystal angular position analysis for analyzer-based phase-contrast imaging

    Science.gov (United States)

    Majidi, Keivan; Li, Jun; Muehleman, Carol; Brankov, Jovan G.

    2014-04-01

    The analyzer-based phase-contrast x-ray imaging (ABI) method is emerging as a potential alternative to conventional radiography. Like many of the modern imaging techniques, ABI is a computed imaging method (meaning that images are calculated from raw data). ABI can simultaneously generate a number of planar parametric images containing information about absorption, refraction, and scattering properties of an object. These images are estimated from raw data acquired by measuring (sampling) the angular intensity profile of the x-ray beam passed through the object at different angular positions of the analyzer crystal. The noise in the estimated ABI parametric images depends upon imaging conditions like the source intensity (flux), measurements angular positions, object properties, and the estimation method. In this paper, we use the Cramér-Rao lower bound (CRLB) to quantify the noise properties in parametric images and to investigate the effect of source intensity, different analyzer-crystal angular positions and object properties on this bound, assuming a fixed radiation dose delivered to an object. The CRLB is the minimum bound for the variance of an unbiased estimator and defines the best noise performance that one can obtain regardless of which estimation method is used to estimate ABI parametric images. The main result of this paper is that the variance (hence the noise) in parametric images is directly proportional to the source intensity and only a limited number of analyzer-crystal angular measurements (eleven for uniform and three for optimal non-uniform) are required to get the best parametric images. The following angular measurements only spread the total dose to the measurements without improving or worsening CRLB, but the added measurements may improve parametric images by reducing estimation bias. Next, using CRLB we evaluate the multiple-image radiography, diffraction enhanced imaging and scatter diffraction enhanced imaging estimation techniques

  11. Noise and analyzer-crystal angular position analysis for analyzer-based phase-contrast imaging

    International Nuclear Information System (INIS)

    Majidi, Keivan; Brankov, Jovan G; Li, Jun; Muehleman, Carol

    2014-01-01

    The analyzer-based phase-contrast x-ray imaging (ABI) method is emerging as a potential alternative to conventional radiography. Like many of the modern imaging techniques, ABI is a computed imaging method (meaning that images are calculated from raw data). ABI can simultaneously generate a number of planar parametric images containing information about absorption, refraction, and scattering properties of an object. These images are estimated from raw data acquired by measuring (sampling) the angular intensity profile of the x-ray beam passed through the object at different angular positions of the analyzer crystal. The noise in the estimated ABI parametric images depends upon imaging conditions like the source intensity (flux), measurements angular positions, object properties, and the estimation method. In this paper, we use the Cramér–Rao lower bound (CRLB) to quantify the noise properties in parametric images and to investigate the effect of source intensity, different analyzer-crystal angular positions and object properties on this bound, assuming a fixed radiation dose delivered to an object. The CRLB is the minimum bound for the variance of an unbiased estimator and defines the best noise performance that one can obtain regardless of which estimation method is used to estimate ABI parametric images. The main result of this paper is that the variance (hence the noise) in parametric images is directly proportional to the source intensity and only a limited number of analyzer-crystal angular measurements (eleven for uniform and three for optimal non-uniform) are required to get the best parametric images. The following angular measurements only spread the total dose to the measurements without improving or worsening CRLB, but the added measurements may improve parametric images by reducing estimation bias. Next, using CRLB we evaluate the multiple-image radiography, diffraction enhanced imaging and scatter diffraction enhanced imaging estimation techniques

  12. Large-image intensifier photofluorography and conventional radiography in pulmonary emphysema

    International Nuclear Information System (INIS)

    Manninen, H.; Partanen, K.; Soimakallio, S.; Rytkoenen, H.

    1988-01-01

    Large-screen image intensifier (II) photofluorography was compared with full-size screen-film chest radiography in the diagnosis of pulmonary emphysema in 84 patients. Photospot films and conventional radiographs were interpreted independently by three radiologists. Computed tomography (CT) was used as an independent reference technique, and diagnostic performance of chest radiography in various CT patterns of emphysema was evaluated. The difference in diagnostic sensitivity for emphysema in favor of conventional chest radiography over photofluorography (0.65 versus 0.56) was statistically significant (p < 0.05). Specificity of the imaging modalities was equal: 0.78 in full-size films and 0.77 in photospot films. All CT patterns of emphysema had great false negative response rates in chest radiography, which is an inaccurate technique for the diagnosis of emphysema. CT is required for reliable radiologic evaluation of emphysema. (orig.)

  13. Automatic detection of patient identification and positioning errors in radiotherapy treatment using 3D setup images

    OpenAIRE

    Jani, Shyam

    2015-01-01

    The success of modern radiotherapy treatment depends on the correct alignment of the radiation beams with the target region in the patient. In the conventional paradigm of image-guided radiation therapy, 2D or 3D setup images are taken immediately prior to treatment and are used by radiation therapy technologists to localize the patient to the same position as defined from the reference planning CT dataset. However, numerous reports in the literature have described errors during this step, wh...

  14. Radiopacity of restorative composites by conventional radiography and digital images with different resolutions

    Energy Technology Data Exchange (ETDEWEB)

    Dantas, Raquel Venancio; Samento, Hugo Ramalho [Graduate Program in Dentistry, Federal University of Pelotas, Pelotas (Brazil); Duarte, Rosangela Marques; Raso, Sonia Saeger Meireles Monte; De Andrade Ana Karina Maciel; Anjos-Pontual Maria Luiza Dos [Dept. of Operative Dentistry, Federal University of Paraiba, Pelotas (Brazil)

    2013-09-15

    This study was performed to evaluate and compare the radiopacity of dentin, enamel, and 8 restorative composites on conventional radiograph and digital images with different resolutions. Specimens were fabricated from 8 materials and human molars were longitudinally sectioned 1.0 mm thick to include both enamel and dentin. The specimens and tooth sections were imaged by conventional radiograph using 4 sized intraoral film and digital images were taken in high speed and high resolution modes using a phosphor storage plate. Densitometric evaluation of the enamel, dentin, restorative materials, a lead sheet, and an aluminum step wedge was performed on the radiographic images. For the evaluation, the Al equivalent (mm) for each material was calculated. The data were analyzed using one-way ANOVA and Tukey's test (p<0.05), considering the material factor and then the radiographic method factor, individually. The high speed mode allowed the highest radiopacity, while the high resolution mode generated the lowest values. Furthermore, the high resolution mode was the most efficient method for radiographic differentiation between restorative composites and dentin. The conventional radiograph was the most effective in enabling differentiation between enamel and composites. The high speed mode was the least effective in enabling radiographic differentiation between the dental tissues and restorative composites. The high speed mode of digital imaging was not effective for differentiation between enamel and composites. This made it less effective than the high resolution mode and conventional radiographs. All of the composites evaluated showed radiopacity values that fit the ISO 4049 recommendations.

  15. High-resolution storage phosphor imaging of the chest: Comparison with conventional screen-film systems

    International Nuclear Information System (INIS)

    Fuhrman, C.R.; Good, B.; Feist, J.; Gur, D.; Darby, J.

    1987-01-01

    An experimental high-resolution storage phosphor imaging system (Eastman Kodak) has been used to evaluate the image quality and impact on diagnostic interpretation of storage phosphor images relative to conventional screen-film images of the same patients. The elements of the system include a high-resolution laser scanner (4K X 5K X 12 bit); an image processing system; and a high-resolution (4K X 5K X 12 bit) laser printer. Each case was digitally printed onto film in two different formats: a full-size (14 X 14-inch) and a half-size format of four processed, minified images (7 X 7-inches each). The multiformat image includes an original, an unsharp-masked, a reversed (black bone) unsharp-masked, and a high-contrast unsharp-masked image. The results of this preliminary study (11 cases, eight readers) clearly indicate that after minimal adjustment, radiologists do not object to making diagnoses from minified images. Unsharp masked images were considered preferable to unprocessed images, and processed storage phosphor images were rated significantly better than conventional film images

  16. Current and future diagnostic tools for traumatic brain injury: CT, conventional MRI, and diffusion tensor imaging.

    Science.gov (United States)

    Brody, David L; Mac Donald, Christine L; Shimony, Joshua S

    2015-01-01

    Brain imaging plays a key role in the assessment of traumatic brain injury. In this review, we present our perspectives on the use of computed tomography (CT), conventional magnetic resonance imaging (MRI), and newer advanced modalities such as diffusion tensor imaging. Specifically, we address assessment for immediately life-threatening intracranial lesions (noncontrast head CT), assessment of progression of intracranial lesions (noncontrast head CT), documenting intracranial abnormalities for medicolegal reasons (conventional MRI with blood-sensitive sequences), presurgical planning for post-traumatic epilepsy (high spatial resolution conventional MRI), early prognostic decision making (conventional MRI with diffusion-weighted imaging), prognostic assessment for rehabilitative planning (conventional MRI and possibly diffusion tensor imaging in the future), stratification of subjects and pharmacodynamic tracking of targeted therapies in clinical trials (specific MRI sequences or positron emission tomography (PET) ligands, e.g., diffusion tensor imaging for traumatic axonal injury). We would like to emphasize that all of these methods, especially the newer research approaches, require careful radiologic-pathologic validation for optimal interpretation. We have taken this approach in a mouse model of pericontusional traumatic axonal injury. We found that the extent of reduction in the diffusion tensor imaging parameter relative anisotropy directly correlated with the number of amyloid precursor protein (APP)-stained axonal varicosities (r(2)=0.81, p<0.0001, n=20 injured mice). Interestingly, however, the least severe contusional injuries did not result in APP-stained axonal varicosities, but did cause reduction in relative anisotropy. Clearly, both the imaging assessments and the pathologic assessments will require iterative refinement. © 2015 Elsevier B.V. All rights reserved.

  17. 7T MRI in focal epilepsy with unrevealing conventional field strength imaging.

    Science.gov (United States)

    De Ciantis, Alessio; Barba, Carmen; Tassi, Laura; Cosottini, Mirco; Tosetti, Michela; Costagli, Mauro; Bramerio, Manuela; Bartolini, Emanuele; Biagi, Laura; Cossu, Massimo; Pelliccia, Veronica; Symms, Mark R; Guerrini, Renzo

    2016-03-01

    To assess the diagnostic yield of 7T magnetic resonance imaging (MRI) in detecting and characterizing structural lesions in patients with intractable focal epilepsy and unrevealing conventional (1.5 or 3T) MRI. We conducted an observational clinical imaging study on 21 patients (17 adults and 4 children) with intractable focal epilepsy, exhibiting clinical and electroencephalographic features consistent with a single seizure-onset zone (SOZ) and unrevealing conventional MRI. Patients were enrolled at two tertiary epilepsy surgery centers and imaged at 7T, including whole brain (three-dimensional [3D] T1 -weighted [T1W] fast-spoiled gradient echo (FSPGR), 3D susceptibility-weighted angiography [SWAN], 3D fluid-attenuated inversion recovery [FLAIR]) and targeted imaging (2D T2*-weighted dual-echo gradient-recalled echo [GRE] and 2D gray-white matter tissue border enhancement [TBE] fast spin echo inversion recovery [FSE-IR]). MRI studies at 1.5 or 3T deemed unrevealing at the referral center were reviewed by three experts in epilepsy imaging. Reviewers were provided information regarding the suspected localization of the SOZ. The same team subsequently reviewed 7T images. Agreement in imaging interpretation was reached through consensus-based discussions based on visual identification of structural abnormalities and their likely correlation with clinical and electrographic data. 7T MRI revealed structural lesions in 6 (29%) of 21 patients. The diagnostic gain in detection was obtained using GRE and FLAIR images. Four of the six patients with abnormal 7T underwent epilepsy surgery. Histopathology revealed focal cortical dysplasia (FCD) in all. In the remaining 15 patients (71%), 7T MRI remained unrevealing; 4 of the patients underwent epilepsy surgery and histopathologic evaluation revealed gliosis. 7T MRI improves detection of epileptogenic FCD that is not visible at conventional field strengths. A dedicated protocol including whole brain FLAIR and GRE images at 7T

  18. In vivo imaging of chromogranin A-positive endocrine tumours by three-step monoclonal antibody targeting

    International Nuclear Information System (INIS)

    Siccardi, A.G.; Paganelli, G.; Pontiroli, A.E.; Pelagi, M.; Magnani, P.; Viale, G.; Faglia, G.; Fazio, F.

    1996-01-01

    The detection of chromogranins (Cg) by immunohistochemistry and serology represents a new in vitro diagnostic tool for endocrine tumours. We have recently reported on the feasibility of targeting chromogranin A (CgA) for in vivo detection of pituitary adenomas by immunoscintigraphy (ISG). The scintigraphic procedure, based on an anti-CgA monoclonal antibody and on the avidin-biotin three-step method (Cg-3S-ISG), was evaluated on a group of 29 consecutive patients with known or suspected endocrine tumours other than pituitary adenomas, i.e. medullary thyroid carcinoma, carcinoid, insulinoma and parathormone- or ACTH-producing tumours. Primary tumours (10) and recurrences (16) were visualised in 26 patients, whereas conventional imaging techniques (planar radiography, computerised tomography, magnetic resonance imaging and ultrasonography) failed to detect the tumour sites in ten of the same (Cg-3S-ISG-positive) patients. Therefore, these preliminary results indicate that Cg-3S-ISG, the first immunological method able to detect endocrine tumours in vivo, has a higher diagnostic accuracy than conventional imaging techniques (93.1% compared with 65.5%). (orig.). With 3 figs., 1 tab

  19. Reproducibility of lateral cephalometric landmarks on conventional radiographs and spatial frequency-processed digital images

    International Nuclear Information System (INIS)

    Shin, Jeong Won; Heo, Min Suk; Lee, Sam Sun; Choi, Hyun Bae; Choi, Soon Chul; Choi, Hang Moon

    2002-01-01

    Computed radiography (CR) has been used in cephalometric radiography and many studies have been carried out to improve image quality using various digital enhancement and filtering techniques. During CR image acquisition, the frequency rank and type affect to the image quality. The aim of this study was to compare the diagnostic quality of conventional cephalometric radiographs to those of computed radiography. The diagnostic quality of conventional cephalometric radiographs (M0) and their digital image counterparts were compared, and at the same time, six modalities (M1-M6) of spatial frequency-processed digital images were compared by evaluating the reproducibility of 23 cephalometric landmark locations. Reproducibility was defined as an observer's deviation (in mm) from the mean between all observers. In comparison with the conventional cephalometric radiograph (M0), M1 showed statistically significant differences in 8 locations, M2 in 9, M3 12, M4 in 7, M5 in 12, and M6 showed significant differences in 14 of 23 landmark locations (p<0.05). The number of reproducible landmarks that each modality possesses were 7 in M6, 6 in M5, 5 in M3, 4 in M4, 3 in M2, 2 in M1, and 1 location in M0. The image modality that observers selected as having the best image quality was M5.

  20. Vertebral Fracture Assessment in Supine Position : Comparison by Using Conventional Semiquantitative Radiography and Visual Radiography

    NARCIS (Netherlands)

    Hospers, Ilone C.; van der Laan, Johan G.; Zeebregts, Clark J.; Nieboer, Patrick; Wolffenbuttel, Bruce H. R.; Dierckx, Rudi A.; Kreeftenberg, Herman G.; Jager, Pieter L.; Slart, Riemer H. J. A.

    Purpose: To retrospectively evaluate the accuracy of vertebral fracture assessment (VFA) performed with the patient in the supine position and conventional semiquantitative radiography of the spine by using conventional visual radiography of the spine as the reference standard. Materials and

  1. Computed and conventional chest radiography: a comparison of image quality and radiation dose

    International Nuclear Information System (INIS)

    Ramli, K.; Abdullah, B.J.J.; Ng, K-H.; Hussain, A.F.; Mahmud, R.

    2005-01-01

    The aim of this study was to compare the image quality and entrance skin dose (ESD) for film-screen and computed chest radiography. Analysis of the image quality and dose on chest radiography was carried out on a conventional X-ray unit using film-screen, storage phosphor plates and selenium drum direct chest radiography. For each receptor, ESD was measured in 60 patients using thermoluminescent dosemeters. Images were printed on 35 x 43 cm films. Image quality was assessed subjectively by evaluation of anatomic features and estimation of the image quality, following the guidelines established by the protocols of the Commission of the European Communities. There was no statistically significant difference noted between the computed and conventional images (Wilcoxon rank sum test, P>0.05). Imaging of the mediastinum and peripheral lung structures were better visualized with the storage phosphor and selenium drum technique than with the film-screen combination. The patients' mean ESD for chest radiography using the storage phosphor, film-screen combination and selenium drum was 0.20, 0.20 and 0.25 mGy, respectively, with no statistically significant difference with P > 0.05 (χ 2 tests) Copyright (2005) Blackwell Publishing Asia Pty Ltd

  2. Diuretic-enhanced gadolinium excretory MR urography: comparison of conventional gradient-echo sequences and echo-planar imaging

    Energy Technology Data Exchange (ETDEWEB)

    Nolte-Ernsting, C.C.A.; Tacke, J.; Adam, G.B.; Haage, P.; Guenther, R.W. [Univ. of Technology, Aachen (Germany). Dept. of Diagnostic Radiology; Jung, P.; Jakse, G. [Univ. of Technology, Aachen (Germany). Dept. of Urology

    2001-01-01

    The aim of this study was to investigate the utility of different gadolinium-enhanced T1-weighted gradient-echo techniques in excretory MR urography. In 74 urologic patients, excretory MR urography was performed using various T1-weighted gradient-echo (GRE) sequences after injection of gadolinium-DTPA and low-dose furosemide. The examinations included conventional GRE sequences and echo-planar imaging (GRE EPI), both obtained with 3D data sets and 2D projection images. Breath-hold acquisition was used primarily. In 20 of 74 examinations, we compared breath-hold imaging with respiratory gating. Breath-hold imaging was significantly superior to respiratory gating for the visualization of pelvicaliceal systems, but not for the ureters. Complete MR urograms were obtained within 14-20 s using 3D GRE EPI sequences and in 20-30 s with conventional 3D GRE sequences. Ghost artefacts caused by ureteral peristalsis often occurred with conventional 3D GRE imaging and were almost completely suppressed in EPI sequences (p < 0.0001). Susceptibility effects were more pronounced on GRE EPI MR urograms and calculi measured 0.8-21.7% greater in diameter compared with conventional GRE sequences. Increased spatial resolution degraded the image quality only in GRE-EPI urograms. (orig.)

  3. MRI of persistent cloaca: Can it substitute conventional imaging?

    Energy Technology Data Exchange (ETDEWEB)

    Mohammad, Shaimaa Abdelsattar, E-mail: shaimaa96@hotmail.com [Department of Radiodiagnosis, Faculty of Medicine, Ain-Shams University (Egypt); AbouZeid, Amr Abdelhamid, E-mail: amrabdelhamid@hotmail.com [Department of Pediatric Surgery, Faculty of Medicine, Ain-Shams University (Egypt)

    2013-02-15

    Purpose: To define the role of MRI in the preoperative assessment of patients with persistent cloaca and whether it can substitute other imaging modalities. Methods: We prospectively examined eleven patients with persistent cloaca between July 2007 and March 2012. Non contrast MRI examinations were performed on 1.5 T magnet using head coil. Multiple pulse sequences (T1WI, T2WI, fat suppression) were obtained in axial, sagittal and coronal planes of the pelvis, abdomen, and spine. The scans were reviewed for the following: the level and type of rectal termination, the developmental state of striated muscle complex (SMC), associated genitourinary and spinal anomalies. MRI findings were compared to conventional fluoroscopic imaging, operative and endoscopic findings. We applied novel MRI parameters (urethral length, relative hiatal distance and vaginal volume). The relation between different parameters was tested statistically using Pearson correlation test. Results: MRI could accurately demonstrate the level of bowel termination in patients with persistent cloaca, in addition to its high sensitivity for detection of mullerian anomalies which were present in 73% of patients. Furthermore, MRI could disclose associating renal and spinal anomalies, and assess the developmental state of SMC. The shorter the urethra (higher urogenital confluence), the narrower the pelvic hiatus, and the more was the obstruction (vaginal distension). Conclusion: MRI is a valuable tool in exploring the different internal anatomical features of the cloacal anomaly; and when combined with endoscopy, MRI can make other preoperative conventional imaging unnecessary.

  4. Operation logic and functionality of automatic dose rate and image quality control of conventional fluoroscopy

    International Nuclear Information System (INIS)

    Lin, Pei-Jan Paul

    2009-01-01

    New generation of fluoroscopic imaging systems is equipped with spectral shaping filters complemented with sophisticated automatic dose rate and image quality control logic called ''fluoroscopy curve'' or ''trajectory''. Such fluoroscopy curves were implemented first on cardiovascular angiographic imaging systems and are now available on conventional fluoroscopy equipment. This study aims to investigate the control logic operations under the fluoroscopy mode and acquisition mode (equivalent to the legacy spot filming) of a conventional fluoroscopy system typically installed for upper-lower gastrointestinal examinations, interventional endoscopy laboratories, gastrointestinal laboratory, and pain clinics.

  5. Comparison between the implementation of quality criteria of radiographic image in conventional and digital mammography equipments

    International Nuclear Information System (INIS)

    Alcantara, M.C.; Sordi, G.M.A.A.; Caldas, L.V.E.; Furquim, T.A.C.

    2008-01-01

    The mammographic examination needs a strict quality control. A publication of the European Commission provides guidelines on quality criteria for the images of the breast, quantifying the quality obtained in the image. Following the recommendations of the European Commission, two kinds of mammographic equipments, at a same institution, were evaluated to compare the quality of the conventional and digital images. Besides of that, the Average Glandular Dose (AGD) and the Entrance Surface Dose (ESD) were measured by using an ionization chamber (Radcal, 6M) in the radiation beams of each equipment. The digital equipment fulfills more quality criteria than the conventional equipment, provided ESD values, AGD values and a rejection index lower than the conventional equipment. Therefore, the digital mammography can be considered more adequate than the conventional one, both for criteria analyses and for dose optimization. (author)

  6. Comparison between conventional protective mechanical ventilation and high-frequency oscillatory ventilation associated with the prone position.

    Science.gov (United States)

    Fioretto, José Roberto; Klefens, Susiane Oliveira; Pires, Rafaelle Fernandes; Kurokawa, Cilmery Suemi; Carpi, Mario Ferreira; Bonatto, Rossano César; Moraes, Marcos Aurélio; Ronchi, Carlos Fernando

    2017-01-01

    To compare the effects of high-frequency oscillatory ventilation and conventional protective mechanical ventilation associated with the prone position on oxygenation, histology and pulmonary oxidative damage in an experimental model of acute lung injury. Forty-five rabbits with tracheostomy and vascular access were underwent mechanical ventilation. Acute lung injury was induced by tracheal infusion of warm saline. Three experimental groups were formed: healthy animals + conventional protective mechanical ventilation, supine position (Control Group; n = 15); animals with acute lung injury + conventional protective mechanical ventilation, prone position (CMVG; n = 15); and animals with acute lung injury + high-frequency oscillatory ventilation, prone position (HFOG; n = 15). Ten minutes after the beginning of the specific ventilation of each group, arterial gasometry was collected, with this timepoint being called time zero, after which the animal was placed in prone position and remained in this position for 4 hours. Oxidative stress was evaluated by the total antioxidant performance assay. Pulmonary tissue injury was determined by histopathological score. The level of significance was 5%. Both groups with acute lung injury showed worsening of oxygenation after induction of injury compared with the Control Group. After 4 hours, there was a significant improvement in oxygenation in the HFOG group compared with CMVG. Analysis of total antioxidant performance in plasma showed greater protection in HFOG. HFOG had a lower histopathological lesion score in lung tissue than CMVG. High-frequency oscillatory ventilation, associated with prone position, improves oxygenation and attenuates oxidative damage and histopathological lung injury compared with conventional protective mechanical ventilation.

  7. Accuracy of reading liquid based cytology slides using the ThinPrep Imager compared with conventional cytology: prospective study

    Science.gov (United States)

    d'Assuncao, Jefferson; Irwig, Les; Macaskill, Petra; Chan, Siew F; Richards, Adele; Farnsworth, Annabelle

    2007-01-01

    Objective To compare the accuracy of liquid based cytology using the computerised ThinPrep Imager with that of manually read conventional cytology. Design Prospective study. Setting Pathology laboratory in Sydney, Australia. Participants 55 164 split sample pairs (liquid based sample collected after conventional sample from one collection) from consecutive samples of women choosing both types of cytology and whose specimens were examined between August 2004 and June 2005. Main outcome measures Primary outcome was accuracy of slides for detecting squamous lesions. Secondary outcomes were rate of unsatisfactory slides, distribution of squamous cytological classifications, and accuracy of detecting glandular lesions. Results Fewer unsatisfactory slides were found for imager read cytology than for conventional cytology (1.8% v 3.1%; Pcytology (7.4% v 6.0% overall and 2.8% v 2.2% for cervical intraepithelial neoplasia of grade 1 or higher). Among 550 patients in whom imager read cytology was cervical intraepithelial neoplasia grade 1 or higher and conventional cytology was less severe than grade 1, 133 of 380 biopsy samples taken were high grade histology. Among 294 patients in whom imager read cytology was less severe than cervical intraepithelial neoplasia grade 1 and conventional cytology was grade 1 or higher, 62 of 210 biopsy samples taken were high grade histology. Imager read cytology therefore detected 71 more cases of high grade histology than did conventional cytology, resulting from 170 more biopsies. Similar results were found when one pathologist reread the slides, masked to cytology results. Conclusion The ThinPrep Imager detects 1.29 more cases of histological high grade squamous disease per 1000 women screened than conventional cytology, with cervical intraepithelial neoplasia grade 1 as the threshold for referral to colposcopy. More imager read slides than conventional slides were satisfactory for examination and more contained low grade cytological

  8. Agreement between image grading of conventional (45°) and ultra wide-angle (200°) digital images in the macula in the Reykjavik eye study.

    Science.gov (United States)

    Csutak, A; Lengyel, I; Jonasson, F; Leung, I; Geirsdottir, A; Xing, W; Peto, T

    2010-10-01

    To establish the agreement between image grading of conventional (45°) and ultra wide-angle (200°) digital images in the macula. In 2008, the 12-year follow-up was conducted on 573 participants of the Reykjavik Eye Study. This study included the use of the Optos P200C AF ultra wide-angle laser scanning ophthalmoscope alongside Zeiss FF 450 conventional digital fundus camera on 121 eyes with or without age-related macular degeneration using the International Classification System. Of these eyes, detailed grading was carried out on five cases each with hard drusen, geographic atrophy and chorioretinal neovascularisation, and six cases of soft drusen. Exact agreement and κ-statistics were calculated. Comparison of the conventional and ultra wide-angle images in the macula showed an overall 96.43% agreement (κ=0.93) with no disagreement at end-stage disease; although in one eye chorioretinal neovascularisation was graded as drusenoid pigment epithelial detachment. Of patients with drusen only, the exact agreement was 96.1%. The detailed grading showed no clinically significant disagreement between the conventional 45° and 200° images. On the basis of our results, there is a good agreement between grading conventional and ultra wide-angle images in the macula.

  9. In vivo sectional imaging of the retinal periphery using conventional optical coherence tomography systems

    Directory of Open Access Journals (Sweden)

    Abhishek Kothari

    2012-01-01

    Full Text Available Optical coherence tomography (OCT has transformed macular disease practices. This report describes the use of conventional OCT systems for peripheral retinal imaging. Thirty-six eyes with peripheral retinal pathology underwent imaging with conventional OCT systems. In vivo sectional imaging of lattice degeneration, snail-track degeneration, and paving-stone degeneration was performed. Differences were noted between phenotypes of lattice degeneration. Several findings previously unreported in histopathology studies were encountered. Certain anatomic features were seen that could conceivably explain clinical and intraoperative behavior of peripheral lesions. Peripheral OCT imaging helped elucidate clinically ambiguous situations such as retinal breaks, subclinical retinal detachment, retinoschisis, choroidal nevus, and metastasis. Limitations of such scanning included end-gaze nystagmus and far peripheral lesions. This first of its kind study demonstrates the feasibility of peripheral retinal OCT imaging and expands the spectrum of indications for which OCT scanning may be clinically useful.

  10. In vivo sectional imaging of the retinal periphery using conventional optical coherence tomography systems.

    Science.gov (United States)

    Kothari, Abhishek; Narendran, V; Saravanan, V R

    2012-01-01

    Optical coherence tomography (OCT) has transformed macular disease practices. This report describes the use of conventional OCT systems for peripheral retinal imaging. Thirty-six eyes with peripheral retinal pathology underwent imaging with conventional OCT systems. In vivo sectional imaging of lattice degeneration, snail-track degeneration, and paving-stone degeneration was performed. Differences were noted between phenotypes of lattice degeneration. Several findings previously unreported in histopathology studies were encountered. Certain anatomic features were seen that could conceivably explain clinical and intraoperative behavior of peripheral lesions. Peripheral OCT imaging helped elucidate clinically ambiguous situations such as retinal breaks, subclinical retinal detachment, retinoschisis, choroidal nevus, and metastasis. Limitations of such scanning included end-gaze nystagmus and far peripheral lesions. This first of its kind study demonstrates the feasibility of peripheral retinal OCT imaging and expands the spectrum of indications for which OCT scanning may be clinically useful.

  11. Imaging in early rheumatoid arthritis: roles of magnetic resonance imaging, ultrasonography, conventional radiography and computed tomography

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Ejbjerg, Bo; Szkudlarek, Marcin

    2005-01-01

    Efficient methods for diagnosis, monitoring and prognostication are essential in early rheumatoid arthritis (RA). While conventional X-rays only visualize the late signs of preceding disease activity, there is evidence for magnetic resonance imaging (MRI) and ultrasonography being highly sensitiv...

  12. Diagnostic accuracy of artificially induced vertical root fractures: a comparison of direct digital periapical images with conventional periapical images

    International Nuclear Information System (INIS)

    Lee, Ji Un; Kwon, Ki Jeong; Koh, Kwang Joon

    2004-01-01

    To compare the diagnostic accuracy for the detection of root fractures in CMOS-based digital periapical images with conventional film-based periapical images. Sixty extracted single-root human teeth with closed apices were prepared endodontically and divided into two groups; artificially induced vertical root fracture group and control group. All radiographs were obtained using the paralleling technique. The radiographs were examined by 4 observers three times within a 4 week interval. Receiver operating characteristic (ROC) analysis was carried out using data obtained from four observers. Intra- and inter-examiner agreements were computed using kappa analysis. The area under the ROC curve (Az) was used as an indicator of the diagnostic accuracy of the imaging system. Az values were as follows: direct-digital images; 0.93, film-based images; 0.92, and inverted digital images; 0.91. There was no significant difference between imaging modalities(P<0.05). The kappa value of inter-observer agreement was 0.42(range:0.28-0.60) and intra-observer agreement was 0.57(range:0.44-0.75). There is no statistical difference in diagnostic accuracy for the detection of vertical root fractures between digital periapical images and conventional periapical images. The results indicate that the CMOS sensor is a good image detector for the evaluation of vertical root fractures.

  13. Diagnostic equivalence of conventional and fast spin echo magnetic resonance imaging of the anterior cruciate ligament of the knee

    International Nuclear Information System (INIS)

    Munk, P.L.; Hilborn, M.D.; Vellet, A.D.; University of Calgary, Calgary, Alberta,; Romano, C.C.; University of Calgary, Calgary, Alberta,

    1997-01-01

    Many techniques and pulse sequences have been devised for the assessment of the anterior cruciate ligament. The present study compares fast spin echo (FSE) imaging to conventional spin echo imaging at a field strength of 1.5 T in an effort to determine if these sequences are diagnostically equivalent. Where available, arthroscopy was also done. A total of 52 patients were imaged using both FSE and conventional spin echo sequences. Eight volunteers were used as controls. Arthroscopy was performed on 10 patients. The anterior cruciate ligament was assessed in a blinded fashion by three radiologists. The Kappa statistic was then used to determine the percentage agreement between FSE and conventional spin echo imaging. Fast spin echo sequencing demonstrated a sensitivity of 100%, a specificity of 94.8% and an accuracy of 96.3% when compared to arthroscopy. Conventional spin echo imaging and arthroscopy had a sensitivity of 100%, specificity of 84.6% and an accuracy of 88.9%. The remaining 34 patients who did not undergo arthroscopy were followed clinically because clinical and imaging findings were not suggestive of ACL tears. These demonstrated 72% agreement between FSE and conventional spin echo imaging using the Kappa statistic, with regards to calling ACL normal or having only a low-grade partial tear. Fast spin echo imaging produces images of the anterior cruciate ligament that have similar diagnostic accuracy to conventional spin echo images (P<0.05) within a much shorter scan time. These results however, require further validation in a larger group, preferably with arthroscopic correlation. (author)

  14. Surgical neuro navigator guided by preoperative magnetic resonance images, based on a magnetic position sensor

    International Nuclear Information System (INIS)

    Perini, Ana Paula; Siqueira, Rogerio Bulha; Carneiro, Antonio Adilton Oliveira; Oliveira, Lucas Ferrari de; Machado, Helio Rubens

    2009-01-01

    Image guided neurosurgery enables the neurosurgeon to navigate inside the patient's brain using pre-operative images as a guide and a tracking system, during a surgery. Following a calibration procedure, three-dimensional position and orientation of surgical instruments may be transmitted to computer. The spatial information is used to access a region of interest, in the pre-operative images, displaying them to the neurosurgeon during the surgical procedure. However, when a craniotomy is involved and the lesion is removed, movements of brain tissue can be a significant source of error in these conventional navigation systems. The architecture implemented in this work intends the development of a system to surgical planning and orientation guided by ultrasound image. For surgical orientation, the software developed allows the extraction of slices from the volume of the magnetic resonance images (MRI) with orientation supplied by a magnetic position sensor (Polhemus R ). The slices extracted with this software are important because they show the cerebral area that the neurosurgeon is observing during the surgery, and besides they can be correlated with the intra-operative ultrasound images to detect and to correct the deformation of brain tissue during the surgery. Also, a tool for per-operative navigation was developed, providing three orthogonal planes through the image volume. In the methodology used for the software implementation, the Python tm programming language and the Visualization Toolkit (VTK) graphics library were used. The program to extract slices of the MRI volume allowed the application of transformations in the volume, using coordinates supplied by the position sensor. (author)

  15. A comparison between conventional radiography and digitized image accuracy in proximal caries detection

    Directory of Open Access Journals (Sweden)

    Pangnoosh M

    2003-08-01

    Full Text Available Statement of Problem: Computer Sciences, in radiology, like other fields, is of high importance. It should"nalso be noted that the accuracy of the technique and work conditions affects the radiographs information"nconsiderably. There for, in order to get more accurate diagnostic information, it seems necessary to investigate"ndifferent digitized radiographic techniques and to compare them with the conventional technique."nPurpose: The aim of this study was to compare the accuracy of conventional and digitized radiographic"nimages by three digitization techniques in proximal caries detection."nMaterial and Methods: In this research study, sixty extracted human canines, premolars and molars were"nmounted in blocks and imaged on E-Kodak film, similar to bitewing radiographs. Ten bitewing radiographs"nwere then scanned at 600 d.p.i with flat bed scanner and a digital camera, then digitized at 300 d.p.i with"nanother digital camera. The digitized images were displayed randomly on a high-resolution monitor. Six"nobservers assessed the caries status of 120 proximal surfaces by conventional and digitized images. The"nobserver's scores were compared with the results of the macroscopic examination. Reliability of each"ntechnique was calculated. Data were analyzed using chi-square and ANOVA tests."nResults: No significant differences were detected between different techniques in intact proximal surfaces and"nenamel caries diagnosis. However, digital techniques were more sensitive in dentin caries detection (P<0.05."nConclusions: When conventional film images are digitized, medium resolution (300 d.p.i seems to be"nsufficient. At this resolution the file size is decreased and there is no significant loss of the information"nnecessary for caries diagnosis.

  16. Operation logic and functionality of automatic dose rate and image quality control of conventional fluoroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Pei-Jan Paul [Department of Radiology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts 02115 (United States)

    2009-05-15

    New generation of fluoroscopic imaging systems is equipped with spectral shaping filters complemented with sophisticated automatic dose rate and image quality control logic called ''fluoroscopy curve'' or ''trajectory''. Such fluoroscopy curves were implemented first on cardiovascular angiographic imaging systems and are now available on conventional fluoroscopy equipment. This study aims to investigate the control logic operations under the fluoroscopy mode and acquisition mode (equivalent to the legacy spot filming) of a conventional fluoroscopy system typically installed for upper-lower gastrointestinal examinations, interventional endoscopy laboratories, gastrointestinal laboratory, and pain clinics.

  17. Deep pelvic endometriosis: Limited additional diagnostic value of postcontrast in comparison with conventional MR images

    International Nuclear Information System (INIS)

    Bazot, Marc; Gasner, Adeline; Lafont, Clarisse; Ballester, Marcos; Daraï, Emile

    2011-01-01

    Objectives: To determine the value of postcontrast MR imaging (MRI) in cases of suspected pelvic endometriosis by assessing interobserver variability of MR imaging according to the endometriotic locations. Methods: This retrospective study included 158 patients with clinical suspicion of endometriosis who had undergone surgery after MRI between January 2004 and April 2009. Three radiologists with different degrees of experience were independently asked to determine the presence of rectosigmoid colon, vaginal, and bladder endometriosis using both conventional and a combination of conventional and postcontrast MRI. Descriptive analysis, ROC analysis and interobserver agreements (kappa values) were calculated. Results: Rectosigmoid colon, vaginal, and bladder endometriosis was present in 65, 39 and eight patients, respectively. The accuracy of conventional assessment for readers 1, 2, and 3 for rectosigmoid colon, vaginal and bladder endometriosis was 77.2%, 74.1% and 96.8%, and 73.4%, 76.6% and 98.7%, and 86.1%, 88.6% and 99.4%, respectively. The accuracy of conventional and postcontrast MR images for readers 1, 2, and 3 for rectosigmoid colon, vaginal and bladder endometriosis was 77.8%, 78.5% and 98.1%, and 83.5%, 83.5% and 99.4%, and 87.3%, 89.2% and 99.4%, respectively. Conclusions: Interobserver variability of MRI using conventional MRI alone is excellent for the diagnosis of DPE. No significant benefit of intravenous gadolinium, rectal or vaginal administration has been demonstrated.

  18. Subjective image quality comparison between two digital dental radiographic systems and conventional dental film

    Directory of Open Access Journals (Sweden)

    Muhammed Ajmal

    2014-10-01

    Recommendations: Improved software and hardware for digital imaging systems are now available and these improvements may now yield images that are comparable in quality to conventional film. However, we recommend that studies still use more observers and other statistical methods to produce ideal results.

  19. Avoiding preoperative breast MRI when conventional imaging is sufficient to stage patients eligible for breast conserving therapy

    Energy Technology Data Exchange (ETDEWEB)

    Pengel, Kenneth E., E-mail: k.pengel@nki.nl [Department of Radiology, The Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Loo, Claudette E. [Department of Radiology, The Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Wesseling, Jelle [Department of Pathology, The Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Pijnappel, Ruud M. [Department of Radiology/Image Sciences Institute, University Medical Center Utrecht Heidelberglaan 100, 3584 CX Utrecht (Netherlands); Rutgers, Emiel J.Th. [Department of Surgical Oncology, The Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Gilhuijs, Kenneth G.A. [Department of Radiology, The Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Department of Radiology/Image Sciences Institute, University Medical Center Utrecht Heidelberglaan 100, 3584 CX Utrecht (Netherlands)

    2014-02-15

    Aim: To determine when preoperative breast MRI will not be more informative than available breast imaging and can be omitted in patients eligible for breast conserving therapy (BCT). Methods: We performed an MRI in 685 consecutive patients with 692 invasive breast tumors and eligible for BCT based on conventional imaging and clinical examination. We explored associations between patient, tumor, and conventional imaging characteristics and similarity with MRI findings. Receiver operating characteristic (ROC) analysis was employed to compute the area under the curve (AUC). Results: MRI and conventional breast imaging were similar in 585 of the 692 tumors (85%). At univariate analysis, age (p < 0.001), negative preoperative lymph node status (p = 0.011), comparable tumor diameter at mammography and at ultrasound (p = 0.001), negative HER2 status (p = 0.044), and absence of invasive lobular cancer (p = 0.005) were significantly associated with this similarity. At multivariate analysis, these factors, except HER2 status, retained significant associations. The AUC was 0.68. Conclusions: It is feasible to identify a subgroup of patients prior to preoperative breast MRI, who will most likely show similar results on conventional imaging as on MRI. These findings enable formulation of a practical consensus guideline to determine in which patients a preoperative breast MRI can be omitted.

  20. Avoiding preoperative breast MRI when conventional imaging is sufficient to stage patients eligible for breast conserving therapy

    International Nuclear Information System (INIS)

    Pengel, Kenneth E.; Loo, Claudette E.; Wesseling, Jelle; Pijnappel, Ruud M.; Rutgers, Emiel J.Th.; Gilhuijs, Kenneth G.A.

    2014-01-01

    Aim: To determine when preoperative breast MRI will not be more informative than available breast imaging and can be omitted in patients eligible for breast conserving therapy (BCT). Methods: We performed an MRI in 685 consecutive patients with 692 invasive breast tumors and eligible for BCT based on conventional imaging and clinical examination. We explored associations between patient, tumor, and conventional imaging characteristics and similarity with MRI findings. Receiver operating characteristic (ROC) analysis was employed to compute the area under the curve (AUC). Results: MRI and conventional breast imaging were similar in 585 of the 692 tumors (85%). At univariate analysis, age (p < 0.001), negative preoperative lymph node status (p = 0.011), comparable tumor diameter at mammography and at ultrasound (p = 0.001), negative HER2 status (p = 0.044), and absence of invasive lobular cancer (p = 0.005) were significantly associated with this similarity. At multivariate analysis, these factors, except HER2 status, retained significant associations. The AUC was 0.68. Conclusions: It is feasible to identify a subgroup of patients prior to preoperative breast MRI, who will most likely show similar results on conventional imaging as on MRI. These findings enable formulation of a practical consensus guideline to determine in which patients a preoperative breast MRI can be omitted

  1. A preliminary diffusional kurtosis imaging study of Parkinson disease: comparison with conventional diffusion tensor imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kamagata, Koji; Kamiya, Kouhei; Suzuki, Michimasa; Hori, Masaaki; Yoshida, Mariko; Aoki, Shigeki [Juntendo University School of Medicine, Department of Radiology, Bunkyo-ku, Tokyo (Japan); Tomiyama, Hiroyuki; Hatano, Taku; Motoi, Yumiko; Hattori, Nobutaka [Juntendo University School of Medicine, Department of Neurology, Tokyo (Japan); Abe, Osamu [Nihon University School of Medicine, Department of Radiology, Tokyo (Japan); Shimoji, Keigo [National Center of Neurology and Psychiatry Hospital, Department of Radiology, Tokyo (Japan)

    2014-03-15

    Diffusional kurtosis imaging (DKI) is a more sensitive technique than conventional diffusion tensor imaging (DTI) for assessing tissue microstructure. In particular, it quantifies the microstructural integrity of white matter, even in the presence of crossing fibers. The aim of this preliminary study was to compare how DKI and DTI show white matter alterations in Parkinson disease (PD). DKI scans were obtained with a 3-T magnetic resonance imager from 12 patients with PD and 10 healthy controls matched by age and sex. Tract-based spatial statistics were used to compare the mean kurtosis (MK), mean diffusivity (MD), and fractional anisotropy (FA) maps of the PD patient group and the control group. In addition, a region-of-interest analysis was performed for the area of the posterior corona radiata and superior longitudinal fasciculus (SLF) fiber crossing. FA values in the frontal white matter were significantly lower in PD patients than in healthy controls. Reductions in MK occurred more extensively throughout the brain: in addition to frontal white matter, MK was lower in the parietal, occipital, and right temporal white matter. The MK value of the area of the posterior corona radiata and SLF fiber crossing was also lower in the PD group. DKI detects changes in the cerebral white matter of PD patients more sensitively than conventional DTI. In addition, DKI is useful for evaluating crossing fibers. By providing a sensitive index of brain pathology in PD, DKI may enable improved monitoring of disease progression. (orig.)

  2. Evidence for subwavelength imaging with positive refraction

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Yun Gui [Temasek Laboratories, National University of Singapore, Singapore 119260 (Singapore); Sahebdivan, Sahar; Tyc, Tomas; Leonhardt, Ulf [School of Physics and Astronomy, University of St Andrews, North Haugh, St Andrews KY16 9SS (United Kingdom); Ong, C K, E-mail: ulf@st-andrews.ac.uk [Centre for Superconducting and Magnetic Materials, Department of Physics, National University of Singapore, Singapore 117542 (Singapore)

    2011-03-15

    The resolution of lenses is normally limited by the wave nature of light. Imaging with perfect resolution was believed to rely on negative refraction, but here we present experimental evidence for subwavelength imaging with positive refraction.

  3. Evidence for subwavelength imaging with positive refraction

    International Nuclear Information System (INIS)

    Ma, Yun Gui; Sahebdivan, Sahar; Tyc, Tomas; Leonhardt, Ulf; Ong, C K

    2011-01-01

    The resolution of lenses is normally limited by the wave nature of light. Imaging with perfect resolution was believed to rely on negative refraction, but here we present experimental evidence for subwavelength imaging with positive refraction.

  4. High-resolution MR imaging of triangular fibrocartilage complex (TFCC): comparison of microscopy coils and a conventional small surface coil

    Energy Technology Data Exchange (ETDEWEB)

    Yoshioka, Hiroshi [Department of Radiology, University of Tsukuba, Tsukuba (Japan); Department of Radiology, Brigham and Women' s Hospital, 75 Francis Street, 02115, Boston, MA (United States); Ueno, Teruko; Itai, Yuji [Department of Radiology, University of Tsukuba, Tsukuba (Japan); Tanaka, Toshikazu [Department of Orthopedic Surgery, Tsukuba Kinen Hospital, Tsukuba (Japan); Shindo, Masashi [Tsukuba University Hospital, Tsukuba (Japan)

    2003-10-01

    To compare MR images of the triangular fibrocartilage complex (TFCC) using microscopy coils with those using a conventional surface coil qualitatively and quantitatively. Proton density-weighted images and T2*-weighted images of the TFCC from ten normal volunteers were obtained with a conventional surface coil (C4 coil; 80 mm in diameter), a 47-mm microscopy surface coil and a 23-mm microscopy surface coil at 1.5 T. Qualitative image analysis of MR images with three coils was performed by two radiologists who assigned one of five numerical scores (0, nonvisualization; 1, poor; 2, average; 3, good; 4, excellent) for five TFCC components, which were disc proper, triangular ligament, meniscus homologue, ulnotriquetral and ulnolunate ligament. Quantitative analysis included the signal-to-noise ratio (S/N) of the disc proper of TFCC, the lunate cartilage, the lunate bone and the contrast-noise-ratio (C/N) between articular cartilage and disc proper or bone marrow were measured. All structures show higher scores qualitatively on MR with microscopy coils than those with a C4 coil, and the difference was significant with the exception of the ulnolunate ligament. MR with microscopy coils showed significantly higher S/N values than those with a conventional surface coil (P<0.05 to P<0.001). T2*-weighted images using microscopy coils showed significantly higher cartilage-disc proper C/N and cartilage-bone marrow C/N (P<0.01 to P<0.001). On proton density-weighted images, the C/N between cartilage and disc proper with two microscopy coils was significantly higher (P<0.01) than that with a conventional coil. High-resolution MR images of the normal wrist using microscopy coils were superior to those using a conventional surface coil qualitatively and quantitatively. High-resolution MR imaging with a microscopy coil would be a promising method to diagnose TFCC lesions. (orig.)

  5. Whole-body computed tomography in trauma patients: optimization of the patient scanning position significantly shortens examination time while maintaining diagnostic image quality

    Directory of Open Access Journals (Sweden)

    Hickethier T

    2018-05-01

    Full Text Available Tilman Hickethier,1,* Kamal Mammadov,1,* Bettina Baeßler,1 Thorsten Lichtenstein,1 Jochen Hinkelbein,2 Lucy Smith,3 Patrick Sven Plum,4 Seung-Hun Chon,4 David Maintz,1 De-Hua Chang1 1Department of Radiology, University Hospital of Cologne, Cologne, Germany; 2Department of Anesthesiology and Intensive Care Medicine, University Hospital of Cologne, Cologne, Germany; 3Faculty of Medicine, Memorial University of Newfoundland, St. John’s, Canada; 4Department of General, Visceral and Cancer Surgery, University Hospital of Cologne, Cologne, Germany *These authors contributed equally to this work Background: The study was conducted to compare examination time and artifact vulnerability of whole-body computed tomographies (wbCTs for trauma patients using conventional or optimized patient positioning. Patients and methods: Examination time was measured in 100 patients scanned with conventional protocol (Group A: arms positioned alongside the body for head and neck imaging and over the head for trunk imaging and 100 patients scanned with optimized protocol (Group B: arms flexed on a chest pillow without repositioning. Additionally, influence of two different scanning protocols on image quality in the most relevant body regions was assessed by two blinded readers. Results: Total wbCT duration was about 35% or 3:46 min shorter in B than in A. Artifacts in aorta (27 vs 6%, liver (40 vs 8% and spleen (27 vs 5% occurred significantly more often in B than in A. No incident of non-diagnostic image quality was reported, and no significant differences for lungs and spine were found. Conclusion: An optimized wbCT positioning protocol for trauma patients allows a significant reduction of examination time while still maintaining diagnostic image quality. Keywords: CT scan, polytrauma, acute care, time requirement, positioning

  6. A Comparative Study on Diagnostic Accuracy of Colour Coded Digital Images, Direct Digital Images and Conventional Radiographs for Periapical Lesions – An In Vitro Study

    Science.gov (United States)

    Mubeen; K.R., Vijayalakshmi; Bhuyan, Sanat Kumar; Panigrahi, Rajat G; Priyadarshini, Smita R; Misra, Satyaranjan; Singh, Chandravir

    2014-01-01

    Objectives: The identification and radiographic interpretation of periapical bone lesions is important for accurate diagnosis and treatment. The present study was undertaken to study the feasibility and diagnostic accuracy of colour coded digital radiographs in terms of presence and size of lesion and to compare the diagnostic accuracy of colour coded digital images with direct digital images and conventional radiographs for assessing periapical lesions. Materials and Methods: Sixty human dry cadaver hemimandibles were obtained and periapical lesions were created in first and second premolar teeth at the junction of cancellous and cortical bone using a micromotor handpiece and carbide burs of sizes 2, 4 and 6. After each successive use of round burs, a conventional, RVG and colour coded image was taken for each specimen. All the images were evaluated by three observers. The diagnostic accuracy for each bur and image mode was calculated statistically. Results: Our results showed good interobserver (kappa > 0.61) agreement for the different radiographic techniques and for the different bur sizes. Conventional Radiography outperformed Digital Radiography in diagnosing periapical lesions made with Size two bur. Both were equally diagnostic for lesions made with larger bur sizes. Colour coding method was least accurate among all the techniques. Conclusion: Conventional radiography traditionally forms the backbone in the diagnosis, treatment planning and follow-up of periapical lesions. Direct digital imaging is an efficient technique, in diagnostic sense. Colour coding of digital radiography was feasible but less accurate however, this imaging technique, like any other, needs to be studied continuously with the emphasis on safety of patients and diagnostic quality of images. PMID:25584318

  7. Evidence for subwavelength imaging with positive refraction

    OpenAIRE

    Ma, Yun Gui; Sahebdivan, Sahar; Ong, C. K.; Tyc, Tomas; Leonhardt, Ulf

    2011-01-01

    The resolution of lenses is normally limited by the wave nature of light. Imaging with perfect resolution was believed to rely on negative refraction, but here we present experimental evidence for subwavelength imaging with positive refraction. Publisher PDF Peer reviewed

  8. Comparative study of the macroscopic finding, conventional tomographic imaging, and computed tomographic imaging in locating the mandibular canal

    International Nuclear Information System (INIS)

    Choi, Hang Moon; You, Dong Soo

    1995-01-01

    The purpose of this study was comparison of conventional tomography with reformatted computed tomography for dental implant in locating the mandibular canal. Five dogs were used and after conventional tomographs and fitted computed tomographs were taken, four dentist traced all films. Mandibles were sectioned with 2 mm slice thickness and the sections were then radiographed (contact radiography). Each radiograpic image was traced and linear measurements were made from mandibular canal to alveolar crest, buccal cortex, lingual cortex, and inferior border. The following results were obtained; 1. Reformatted computed tomographs were exacter than conventional tomography by alveolar crest to canal length of -0.6 mm difference between real values and radiographs 2. The average measurements of buccal cortex to mandibular canal width and lingual cortex to mandibular canal width of conventional tomographs were exacter than reformatted computed tomographs, but standard deviations were higher than reformatted computed tomographs. 3. Standard deviations of reformatted computed tomographs were lower than conventional tomographs at all comparing sites 4. At reformatted computed tomography 62.5% of the measurements performed were within ±1 mm of the true value, and at conventional tomography 24.1% were. 5. Mandibular canal invisibility was 0.8% at reformatted computed tomography and 9.2% at conventional tomography. Reformatted computed tomography has been shown to be more useful radiographic technique for assessment of the mandibular canal than conventional tomography.

  9. Imaging technique for the complete edentulous patient treated conventionally or with mini implant overdenture

    Science.gov (United States)

    Meleşcanu Imre, M; Preoteasa, E; Țâncu, AM; Preoteasa, CT

    2013-01-01

    Rationale. The imaging methods are more and more used in the clinical process of modern dentistry. Once the implant based treatment alternatives are nowadays seen as being the standard of care in edentulous patients, these techniques must be integrated in the complete denture treatment. Aim. The study presents some evaluation techniques for the edentulous patient treated by conventional dentures or mini dental implants (mini SKY Bredent) overdentures, using the profile teleradiography. These offer data useful for an optimal positioning of the artificial teeth and the mini dental implants, favoring to obtain an esthetic and functional treatment outcome. We proposed also a method to conceive a simple surgical guide that allows the prosthetically driven implants placement. Material and method. Clinical case reports were made, highlighting the importance of cephalometric evaluation on lateral teleradiographs in complete edentulous patients. A clinical case that gradually reports the surgical guide preparation (Bredent silicon radio opaque), in order to place the mini dental implants in the best prosthetic and anatomic conditions, was presented. Conclusions. The profile teleradiograph is a useful tool for the practitioner. It allows establishing the optimal site for implant placement, in a good relation with the overdenture. The conventional denture can be easily and relatively costless transformed in a surgical guide used during implant placement. PMID:23599828

  10. Performance of a video-image-subtraction-based patient positioning system

    International Nuclear Information System (INIS)

    Milliken, Barrett D.; Rubin, Steven J.; Hamilton, Russell J.; Johnson, L. Scott; Chen, George T.Y.

    1997-01-01

    Purpose: We have developed and tested an interactive video system that utilizes image subtraction techniques to enable high precision patient repositioning using surface features. We report quantitative measurements of system performance characteristics. Methods and Materials: Video images can provide a high precision, low cost measure of patient position. Image subtraction techniques enable one to incorporate detailed information contained in the image of a carefully verified reference position into real-time images. We have developed a system using video cameras providing orthogonal images of the treatment setup. The images are acquired, processed and viewed using an inexpensive frame grabber and a PC. The subtraction images provide the interactive guidance needed to quickly and accurately place a patient in the same position for each treatment session. We describe the design and implementation of our system, and its quantitative performance, using images both to measure changes in position, and to achieve accurate setup reproducibility. Results: Under clinical conditions (60 cm field of view, 3.6 m object distance), the position of static, high contrast objects could be measured with a resolution of 0.04 mm (rms) in each of two dimensions. The two-dimensional position could be reproduced using the real-time image display with a resolution of 0.15 mm (rms). Two-dimensional measurement resolution of the head of a patient undergoing treatment for head and neck cancer was 0.1 mm (rms), using a lateral view, measuring the variation in position of the nose and the ear over the course of a single radiation treatment. Three-dimensional repositioning accuracy of the head of a healthy volunteer using orthogonal camera views was less than 0.7 mm (systematic error) with an rms variation of 1.2 mm. Setup adjustments based on the video images were typically performed within a few minutes. The higher precision achieved using the system to measure objects than to reposition

  11. Conventional and Nuclear Medicine Imaging in Ectopic Cushing's Syndrome: A Systematic Review

    Science.gov (United States)

    Isidori, Andrea M.; Sbardella, Emilia; Zatelli, Maria Chiara; Boschetti, Mara; Vitale, Giovanni; Colao, Annamaria

    2015-01-01

    Context: Ectopic Cushing's Syndrome (ECS) can be a diagnostic challenge with the hormonal source difficult to find. This study analyzes the accuracy of imaging studies in ECS localization. Evidence Acquisition: Systematic review of medical literature for ECS case series providing individual patient data on at least one conventional imaging technique (computed tomography [CT]/magnetic resonance imaging) and one of the following: 111In-pentetreotide (OCT), 131I/123I-metaiodobenzylguanidine, 18F-fluoro-2-deoxyglucose-positron emission tomography (FDG-PET), 18F-fluorodopa-PET (F-DOPA-PET), 68Ga-DOTATATE-PET/CT or 68Ga-DOTATOC-PET/CT scan (68Gallium-SSTR-PET/CT). Evidence Summary: The analysis comprised 231 patients (females, 50.2%; age, 42.6 ± 17 y). Overall, 52.4% (121/231) had “overt” ECS, 18.6% had “occult” ECS, and 29% had “covert” ECS. Tumors were located in the lung (55.3%), mediastinum-thymus (7.9%), pancreas (8.5%), adrenal glands (6.4%), gastrointestinal tract (5.4%), thyroid (3.7%), and other sites (12.8%), and primary tumors were mostly bronchial neuroendocrine tumors (NETs) (54.8%), pancreatic NETs (8%), mediastinum-thymus NETs (6.9%), gastrointestinal NETs (5.3%), pheochromocytoma (6.4%), neuroblastoma (3.2%), and medullary thyroid carcinoma (3.2%). Tumors were localized by CT in 66.2% (137/207), magnetic resonance imaging in 51.5% (53/103), OCT in 48.9% (84/172), FDG-PET in 51.7% (46/89), F-DOPA-PET in 57.1% (12/21), 131/123I-metaiodobenzylguanidine in 30.8% (4/13), and 68Gallium-SSTR-PET/CT in 81.8% (18/22) of cases. Molecular imaging discovered 79.1% (53/67) of tumors unidentified by conventional radiology, with OCT the most commonly used, revealing the tumor in 64%, followed by FDG-PET in 59.4%. F-DOPA-PET was used in only seven covert cases (sensitivity, 85.7%). Notably, 68Gallium-SSTR-PET/CT had 100% sensitivity among covert cases. Conclusions: Nuclear medicine improves the sensitivity of conventional radiology when tumor site

  12. Comparison of morphological and conventional edge detectors in medical imaging applications

    Science.gov (United States)

    Kaabi, Lotfi; Loloyan, Mansur; Huang, H. K.

    1991-06-01

    Recently, mathematical morphology has been used to develop efficient image analysis tools. This paper compares the performance of morphological and conventional edge detectors applied to radiological images. Two morphological edge detectors including the dilation residue found by subtracting the original signal from its dilation by a small structuring element, and the blur-minimization edge detector which is defined as the minimum of erosion and dilation residues of the blurred image version, are compared with the linear Laplacian and Sobel and the non-linear Robert edge detectors. Various structuring elements were used in this study: regular 2-dimensional, and 3-dimensional. We utilized two criterions for edge detector's performance classification: edge point connectivity and the sensitivity to the noise. CT/MR and chest radiograph images have been used as test data. Comparison results show that the blur-minimization edge detector, with a rolling ball-like structuring element outperforms other standard linear and nonlinear edge detectors. It is less noise sensitive, and performs the most closed contours.

  13. Education for a positive self-image in a contemporary school

    Directory of Open Access Journals (Sweden)

    SANJA SIMEL

    2013-09-01

    Full Text Available In today's world characterized by changed systems of values and materialism, pedagogy should emphasize education for a positive self-image, especially in the contemporary school, whose educational goals are freedom, independence and individuality. This theoretical analysis provides a review of research on the importance and relationship of a positive self-image with other factors, such as social skills and academic achievement. Simultaneously, the methods and procedures by which teachers can foster a student's positive self-image are displayed. Although the degree of positive self-thinking is for the most part formed in interaction with other people, it is extremely important to raise students' awareness about their own internal strengths as well as their possibility of choice. The education of a positive self-image can be considered a part of "positive pedagogy" or "positive education" which focuses on traditional skills and happiness, but also joy - fervor that accompanies being (Fromm, 2004, p. 130.

  14. Imaging slit-coupled surface plasmon polaritons using conventional optical microscopy.

    Science.gov (United States)

    Mehfuz, R; Chowdhury, F A; Chau, K J

    2012-05-07

    We develop a technique that now enables surface plasmon polaritons (SPPs) coupled by nano-patterned slits in a metal film to be detected using conventional optical microscopy with standard objective lenses. The crux of this method is an ultra-thin polymer layer on the metal surface, whose thickness can be varied over a nanoscale range to enable controllable tuning of the SPP momentum. At an optimal layer thickness for which the SPP momentum matches the momentum of light emerging from the slit, the SPP coupling efficiency is enhanced about six times relative to that without the layer. The enhanced efficiency results in distinctive and bright plasmonic signatures near the slit visible by naked eye under an optical microscope. We demonstrate how this capability can be used for parallel measurement through a simple experiment in which the SPP propagation distance is extracted from a single microscope image of an illuminated array of nano-patterned slits on a metal surface. We also use optical microscopy to image the focal region of a plasmonic lens and obtain results consistent with a previously-reported results using near-field optical microscopy. Measurement of SPPs near a nano-slit using conventional and widely-available optical microscopy is an important step towards making nano-plasmonic device technology highly accessible and easy-to-use.

  15. Feasibility and evaluation of dual-source transmit 3D imaging of the orbits: Comparison to high-resolution conventional MRI at 3T

    Energy Technology Data Exchange (ETDEWEB)

    Seeger, Achim, E-mail: achim.seeger@gmx.de [Department of Diagnostic and Interventional Neuroradiology, Eberhard-Karls-University, Hoppe-Seyler-Str. 3, Tübingen 72076 (Germany); Schulze, Maximilian, E-mail: maximilian.schulze@med.uni-tuebingen.de [Department of Diagnostic and Interventional Neuroradiology, Eberhard-Karls-University, Hoppe-Seyler-Str. 3, Tübingen 72076 (Germany); Schuettauf, Frank, E-mail: fschuettauf@uni-tuebingen.de [University Eye Hospital, Department of Ophthalmology, Eberhard-Karls-University, Schleichstrasse 12, Tübingen 72076 (Germany); Klose, Uwe, E-mail: uwe.klose@med.uni-tuebingen.de [Department of Diagnostic and Interventional Neuroradiology, Eberhard-Karls-University, Hoppe-Seyler-Str. 3, Tübingen 72076 (Germany); Ernemann, Ulrike, E-mail: ulrike.ernemann@med.uni-tuebingen.de [Department of Diagnostic and Interventional Neuroradiology, Eberhard-Karls-University, Hoppe-Seyler-Str. 3, Tübingen 72076 (Germany); Hauser, Till-Karsten, E-mail: till-karsten.hauser@med.uni-tuebingen.de [Department of Diagnostic and Interventional Neuroradiology, Eberhard-Karls-University, Hoppe-Seyler-Str. 3, Tübingen 72076 (Germany)

    2015-06-15

    Highlights: • Reduced FOV imaging enables a 3D approach for a very fast assessment of the orbits. • Conventional MRI exhibited higher eSNR values and consecutively higher scores for overall image quality in the subjective readers’ analysis. • All pathologies could be detected compared to high-resolution conventional MRI making 3D pTX SPACE to a potential alternative and fast imaging technique. - Abstract: Purpose: To prospectively compare the image quality and diagnostic performance of orbital MR images obtained by using a dual-source parallel transmission (pTX) 3D sequence (Sampling Perfection with Application optimized Contrasts using different flip angle Evolution, SPACE) with the image quality of conventional high-resolution standard protocol for clinical use in patients at 3T. Materials and methods: After obtaining institutional review board approval and patient consent, 32 patients with clinical indication for orbital MRI were examined using a high-resolution conventional sequences and 3D pTX SPACE sequences. Quantitative measurements, image quality of the healthy orbit, incidence of artifacts, and the subjective diagnostic performance to establish diagnosis was rated. Statistical significance was calculated by using a Student's t-test and nonparametric Wilcoxon signed rank test. Results: Length measurements were comparable in the two techniques, 3D pTX SPACE resulted in significant faster image acquisition with higher spatial resolution and less motion artifacts as well as better delineation of the optic nerve sheath. However, estimated contrast-to-noise and signal-to-noise and overall image quality as well as subjective scores of the conventional TSE imaging were rated significantly higher. The conventional MR sequences were the preferred techniques by the readers. Conclusion: This study demonstrates the feasibility of 3D pTX SPACE of the orbit resulting in a rapid acquisition of isotropic high-resolution images. Although no pathology was

  16. Medulloblastoma: correlation among findings of conventional magnetic resonance imaging, diffusion-weighted imaging and proton magnetic resonance spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Fonte, Mariana Vieira de Melo da; Otaduy, Maria Concepcion Garcia; Lucato, Leandro Tavares; Reed, Umbertina Conti; Leite, Claudia da Costa [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Hospital das Clinicas. Inst. de Radiologia]. E-mail: mvmfonte@uol.com.br; Costa, Maria Olivia Rodrigues; Amaral, Raquel Portugal Guimaraes [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Faculdade de Medicina. Dept. de Radiologia; Reed, Umbertina Conti [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Faculdade de Medicina. Dept. de Neurologia; Rosemberg, Sergio [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Hospital das Clinicas. Dept. de Patologia

    2008-11-15

    To correlate imaging findings of medulloblastomas at conventional magnetic resonance imaging, diffusion-weighted imaging and proton magnetic resonance spectroscopy, comparing them with data in the literature. Preoperative magnetic resonance imaging studies of nine pediatric patients with histologically confirmed medulloblastomas (eight desmoplastic medulloblastoma, and one giant cell medulloblastoma) were retrospectively reviewed, considering demographics as well as tumors characteristics such as localization, morphology, signal intensity, contrast-enhancement, dissemination, and diffusion-weighted imaging and spectroscopy findings. In most of cases the tumors were centered in the cerebellar vermis (77.8%), predominantly solid (88.9%), hypointense on T 1-weighted images and intermediate/hyperintense on T 2-FLAIR-weighted images, with heterogeneous enhancement (100%), tumor dissemination/extension (77.8%) and limited water molecule mobility (100%). Proton spectroscopy acquired with STEAM technique (n = 6) demonstrated decreased Na a / Cr ratio (83.3%) and increased Co/Cr (100%) and ml/Cr (66.7%) ratios; and with PRESS technique (n = 7) demonstrated lactate peak (57.1%). Macroscopic magnetic resonance imaging findings in association with biochemical features of medulloblastomas have been useful in the differentiation among the most frequent posterior fossa tumors. (author)

  17. Medulloblastoma: correlation among findings of conventional magnetic resonance imaging, diffusion-weighted imaging and proton magnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    Fonte, Mariana Vieira de Melo da; Otaduy, Maria Concepcion Garcia; Lucato, Leandro Tavares; Reed, Umbertina Conti; Leite, Claudia da Costa; Costa, Maria Olivia Rodrigues; Amaral, Raquel Portugal Guimaraes; Reed, Umbertina Conti; Rosemberg, Sergio

    2008-01-01

    To correlate imaging findings of medulloblastomas at conventional magnetic resonance imaging, diffusion-weighted imaging and proton magnetic resonance spectroscopy, comparing them with data in the literature. Preoperative magnetic resonance imaging studies of nine pediatric patients with histologically confirmed medulloblastomas (eight desmoplastic medulloblastoma, and one giant cell medulloblastoma) were retrospectively reviewed, considering demographics as well as tumors characteristics such as localization, morphology, signal intensity, contrast-enhancement, dissemination, and diffusion-weighted imaging and spectroscopy findings. In most of cases the tumors were centered in the cerebellar vermis (77.8%), predominantly solid (88.9%), hypointense on T 1-weighted images and intermediate/hyperintense on T 2-FLAIR-weighted images, with heterogeneous enhancement (100%), tumor dissemination/extension (77.8%) and limited water molecule mobility (100%). Proton spectroscopy acquired with STEAM technique (n = 6) demonstrated decreased Na a / Cr ratio (83.3%) and increased Co/Cr (100%) and ml/Cr (66.7%) ratios; and with PRESS technique (n = 7) demonstrated lactate peak (57.1%). Macroscopic magnetic resonance imaging findings in association with biochemical features of medulloblastomas have been useful in the differentiation among the most frequent posterior fossa tumors. (author)

  18. Images of the Self and Self-Esteem: Do Positive Self-Images Improve Self-Esteem in Social Anxiety?

    Science.gov (United States)

    Hulme, Natalie; Hirsch, Colette; Stopa, Lusia

    2012-01-01

    Negative self-images play an important role in maintaining social anxiety disorder. We propose that these images represent the working self in a Self-Memory System that regulates retrieval of self-relevant information in particular situations. Self-esteem, one aspect of the working self, comprises explicit (conscious) and implicit (automatic) components. Implicit self-esteem reflects an automatic evaluative bias towards the self that is normally positive, but is reduced in socially anxious individuals. Forty-four high and 44 low socially anxious participants generated either a positive or a negative self-image and then completed measures of implicit and explicit self-esteem. Participants who held a negative self-image in mind reported lower implicit and explicit positive self-esteem, and higher explicit negative self-esteem than participants holding a positive image in mind, irrespective of social anxiety group. We then tested whether positive self-images protected high and low socially anxious individuals equally well against the threat to explicit self-esteem posed by social exclusion in a virtual ball toss game (Cyberball). We failed to find a predicted interaction between social anxiety and image condition. Instead, all participants holding positive self-images reported higher levels of explicit self-esteem after Cyberball than those holding negative self-images. Deliberate retrieval of positive self-images appears to facilitate access to a healthy positive implicit bias, as well as improving explicit self-esteem, whereas deliberate retrieval of negative self-images does the opposite. This is consistent with the idea that negative self-images may have a causal, as well as a maintaining, role in social anxiety disorder. PMID:22439697

  19. Positive post-disaster images: A daydream machine?

    Science.gov (United States)

    Hancock, Nicola J; de Joux, Neil R; Wingreen, Stephen C; Kemp, Simon; Thomas, Jared; Helton, William S

    2017-08-01

    This study explores the impact of post-earthquake images inserted in a vigilance task, in terms of performance, self-reports of task-focus, and cerebral activity using functional near-infrared spectroscopy (fNIRS). Vigilance tasks present a sequence of stimuli in which only a few are pre-designated critical or target stimuli requiring an overt response from the participant. Seventy-one residents participated (51 women, 20 men) by taking part in a vigilance task with task-irrelevant images inserted in the sequence. There were three conditions consisting positive (emotive inducing), negative (emotive inducing), and control (devoid of meaning) images embedded in the vigilance task to assess possible impacts on vigilance performance. The images were obtained through crowdsourcing and represented parts of the city 3-4 years post-earthquake. Task performance was assessed with signal detection theory metrics of sensitivity A' and bias β''. This enables the separation of an individual's ability to accurately discriminate critical signals from non-critical stimuli (sensitivity) and shifts in their willingness to respond to any stimuli whether critical or not (bias). Individuals viewing the positive images, relating to progress, rebuild, or aesthetic aspects within the city, had a more conservative response bias (they responded less to both rare critical and distractor stimuli) than those in the other conditions. These individuals also reported lower task-focus, as would be expected. However, contrary to expectations, indicators of cerebral activity (fNIRS) did not differ significantly between the experimental groups. These results, when combined, suggest that mind wandering events may be being generated when exposed to positive post-earthquake images. © 2016 The British Psychological Society.

  20. Pregnancy failure in patients with obstetric antiphospholipid syndrome with conventional treatment: the influence of a triple positive antibody profile.

    Science.gov (United States)

    Latino, J O; Udry, S; Aranda, F M; Perés Wingeyer, S D A; Fernández Romero, D S; de Larrañaga, G F

    2017-08-01

    Conventional treatment of obstetric antiphospholipid syndrome fails in approximately 20-30% of pregnant women without any clearly identified risk factor. It is important to identify risk factors that are associated with these treatment failures. This study aimed to assess the impact of risk factors on pregnancy outcomes in women with obstetric antiphospholipid syndrome treated with conventional treatment. We carefully retrospectively selected 106 pregnancies in women with obstetric antiphospholipid syndrome treated with heparin + aspirin. Pregnancy outcomes were evaluated according to the following associated risk factors: triple positivity profile, double positivity profile, single positivity profile, history of thrombosis, autoimmune disease, more than four pregnancy losses, and high titers of anticardiolipin antibodies and/or anti-βeta-2-glycoprotein-I (aβ2GPI) antibodies. To establish the association between pregnancy outcomes and risk factors, a single binary logistic regressions analysis was performed. Risk factors associated with pregnancy loss with conventional treatment were: the presence of triple positivity (OR = 5.0, CI = 1.4-16.9, p = 0.01), high titers of aβ2GPI (OR = 4.4, CI = 1.2-16.1, p = 0.023) and a history of more than four pregnancy losses (OR = 3.5, CI = 1.2-10.0, p = 0.018). The presence of triple positivity was an independent risk factor associated with gestational complications (OR = 4.1, CI = 1.2-13.9, p = 0.02). Our findings reinforce the idea that triple positivity is a categorical risk factor for poor response to conventional treatment.

  1. Post mortem magnetic resonance imaging in the fetus, infant and child: A comparative study with conventional autopsy (MaRIAS Protocol

    Directory of Open Access Journals (Sweden)

    Thayyil Sudhin

    2011-12-01

    Full Text Available Abstract Background Minimally invasive autopsy by post mortem magnetic resonance (MR imaging has been suggested as an alternative for conventional autopsy in view of the declining consented autopsy rates. However, large prospective studies rigorously evaluating the accuracy of such an approach are lacking. We intend to compare the accuracy of a minimally invasive autopsy approach using post mortem MR imaging with that of conventional autopsy in fetuses, newborns and children for detection of the major pathological abnormalities and/or determination of the cause of death. Methods/Design We recruited 400 consecutive fetuses, newborns and children referred for conventional autopsy to one of the two participating hospitals over a three-year period. We acquired whole body post mortem MR imaging using a 1.5 T MR scanner (Avanto, Siemens Medical Solutions, Enlargen, Germany prior to autopsy. The total scan time varied between 90 to 120 minutes. Each MR image was reported by a team of four specialist radiologists (paediatric neuroradiology, paediatric cardiology, paediatric chest & abdominal imaging and musculoskeletal imaging, blinded to the autopsy data. Conventional autopsy was performed according to the guidelines set down by the Royal College of Pathologists (UK by experienced paediatric or perinatal pathologists, blinded to the MR data. The MR and autopsy data were recorded using predefined categorical variables by an independent person. Discussion Using conventional post mortem as the gold standard comparator, the MR images will be assessed for accuracy of the anatomical morphology, associated lesions, clinical usefulness of information and determination of the cause of death. The sensitivities, specificities and predictive values of post mortem MR alone and MR imaging along with other minimally invasive post mortem investigations will be presented for the final diagnosis, broad diagnostic categories and for specific diagnosis of each system

  2. Two-dimensional XD-GRASP provides better image quality than conventional 2D cardiac cine MRI for patients who cannot suspend respiration.

    Science.gov (United States)

    Piekarski, Eve; Chitiboi, Teodora; Ramb, Rebecca; Latson, Larry A; Bhatla, Puneet; Feng, Li; Axel, Leon

    2018-02-01

    Residual respiratory motion degrades image quality in conventional cardiac cine MRI (CCMRI). We evaluated whether a free-breathing (FB) radial imaging CCMRI sequence with compressed sensing reconstruction [extradimensional (e.g. cardiac and respiratory phases) golden-angle radial sparse parallel, or XD-GRASP] could provide better image quality than a conventional Cartesian breath-held (BH) sequence in an unselected population of patients undergoing clinical CCMRI. One hundred one patients who underwent BH and FB imaging in a midventricular short-axis plane at a matching location were included. Visual and quantitative image analysis was performed by two blinded experienced readers, using a five-point qualitative scale to score overall image quality and visual signal-to-noise ratio (SNR) grade, with measures of noise and sharpness. End-diastolic and end-systolic left ventricular areas were also measured and compared for both BH and FB images. Image quality was generally better with the BH cines (overall quality grade for BH vs FB images 4 vs 2.9, p XD-GRASP CCMRI was visually inferior to conventional BH CCMRI in general, it provided improved image quality in the subgroup of patients with respiratory-motion-induced artifacts on BH images.

  3. Online Kidney Position Verification Using Non-Contrast Radiographs on a Linear Accelerator with on Board KV X-Ray Imaging Capability

    International Nuclear Information System (INIS)

    Willis, David J.; Kron, Tomas; Hubbard, Patricia; Haworth, Annette; Wheeler, Greg; Duchesne, Gillian M.

    2009-01-01

    The kidneys are dose-limiting organs in abdominal radiotherapy. Kilovoltage (kV) radiographs can be acquired using on-board imager (OBI)-equipped linear accelerators with better soft tissue contrast and lower radiation doses than conventional portal imaging. A feasibility study was conducted to test the suitability of anterior-posterior (AP) non-contrast kV radiographs acquired at treatment time for online kidney position verification. Anthropomorphic phantoms were used to evaluate image quality and radiation dose. Institutional Review Board approval was given for a pilot study that enrolled 5 adults and 5 children. Customized digitally reconstructed radiographs (DRRs) were generated to provide a priori information on kidney shape and position. Radiotherapy treatment staff performed online evaluation of kidney visibility on OBI radiographs. Kidney dose measured in a pediatric anthropomorphic phantom was 0.1 cGy for kV imaging and 1.7 cGy for MV imaging. Kidneys were rated as well visualized in 60% of patients (90% confidence interval, 34-81%). The likelihood of visualization appears to be influenced by the relative AP separation of the abdomen and kidneys, the axial profile of the kidneys, and their relative contrast with surrounding structures. Online verification of kidney position using AP non-contrast kV radiographs on an OBI-equipped linear accelerator appears feasible for patients with suitable abdominal anatomy. Kidney position information provided is limited to 2-dimensional 'snapshots,' but this is adequate in some clinical situations and potentially advantageous in respiratory-correlated treatments. Successful clinical implementation requires customized partial DRRs, appropriate imaging parameters, and credentialing of treatment staff.

  4. Advanced virtual monochromatic reconstruction of dual-energy unenhanced brain computed tomography in children: comparison of image quality against standard mono-energetic images and conventional polychromatic computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Park, Juil [Seoul National University Children' s Hospital, Department of Radiology, Seoul (Korea, Republic of); Choi, Young Hun [Seoul National University Children' s Hospital, Department of Radiology, Seoul (Korea, Republic of); Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Cheon, Jung-Eun; Kim, Woo Sun; Kim, In-One [Seoul National University Children' s Hospital, Department of Radiology, Seoul (Korea, Republic of); Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Seoul National University Medical Research Center, Institute of Radiation Medicine, Seoul (Korea, Republic of); Pak, Seong Yong [Siemens Healthineers, Seoul (Korea, Republic of); Krauss, Bernhard [Siemens Healthineers, Forchheim (Germany)

    2017-11-15

    Advanced virtual monochromatic reconstruction from dual-energy brain CT has not been evaluated in children. To determine the most effective advanced virtual monochromatic imaging energy level for maximizing pediatric brain parenchymal image quality in dual-energy unenhanced brain CT and to compare this technique with conventional monochromatic reconstruction and polychromatic scanning. Using both conventional (Mono) and advanced monochromatic reconstruction (Mono+) techniques, we retrospectively reconstructed 13 virtual monochromatic imaging energy levels from 40 keV to 100 keV in 5-keV increments from dual-source, dual-energy unenhanced brain CT scans obtained in 23 children. We analyzed gray and white matter noise ratios, signal-to-noise ratios and contrast-to-noise ratio, and posterior fossa artifact. We chose the optimal mono-energetic levels and compared them with conventional CT. For Mono+maximum optima were observed at 60 keV, and minimum posterior fossa artifact at 70 keV. For Mono, optima were at 65-70 keV, with minimum posterior fossa artifact at 75 keV. Mono+ was superior to Mono and to polychromatic CT for image-quality measures. Subjective analysis rated Mono+superior to other image sets. Optimal virtual monochromatic imaging using Mono+ algorithm demonstrated better image quality for gray-white matter differentiation and reduction of the artifact in the posterior fossa. (orig.)

  5. Evaluation of head and neck cancer with 18F-FDG PET: a comparison with conventional methods

    International Nuclear Information System (INIS)

    Kresnik, E.; Mikosch, P.; Gallowitsch, H.J.; Heinisch, M.; Unterweger, O.; Kumnig, G.; Gomez, I.; Lind, P.; Kogler, D.; Wieser, S.; Gruenbacher, G.; Raunik, W.

    2001-01-01

    The aim of this study was to evaluate the usefulness of 18 F-FDG PET in the diagnosis and staging of primary and recurrent malignant head and neck tumours in comparison with conventional imaging methods [including ultrasonography, radiography, computed tomography (CT) and magnetic resonance imaging (MRI)], physical examination, panendoscopy and biopsies in clinical routine. A total of 54 patients (13 female, 41 male, age 61.3±12 years) were investigated retrospectively. Three groups were formed. In group I, 18 F-FDG PET was performed in 15 patients to detect unknown primary cancers. In group II, 24 studies were obtained for preoperative staging of proven head and neck cancer. In group III, 18 F-FDG PET was used in 15 patients to monitor tumour recurrence after radiotherapy and/or chemotherapy. In all patients, imaging was obtained at 70 min after the intravenous administration of 180 MBq 18 F-FDG. In 11 of the 15 patients in group I, the primary cancer could be found with 18 F-FDG, yielding a detection rate of 73.3%. In 4 of the 15 patients, CT findings were also suggestive of the primary cancer but were nonetheless equivocal. In these patients, 18 F-FDG showed increased 18 F-FDG uptake by the primary tumour, which was confirmed by histology. One patient had recurrence of breast carcinoma that could not be detected with 18 F-FDG PET, but was detected by CT. In three cases, the primary cancer could not be found with any imaging method. Among the 24 patients in group II investigated for staging purposes, 18 F-FDG PET detected a total of 13 local and three distant lymph node metastases, whereas the conventional imaging methods detected only nine local and one distant lymph node metastases. The results of 18 F-FDG PET led to an upstaging in 5/24 (20.8%) patients. The conventional imaging methods were false positive in 5/24 (20.8%). There was one false positive result using 18 F-FDG PET. Among the 15 patients of group III with suspected recurrence after radiotherapy

  6. 64Cu-DOTA-trastuzumab PET imaging in patients with HER2-positive breast cancer.

    Science.gov (United States)

    Tamura, Kenji; Kurihara, Hiroaki; Yonemori, Kan; Tsuda, Hitoshi; Suzuki, Junko; Kono, Yuzuru; Honda, Natsuki; Kodaira, Makoto; Yamamoto, Harukaze; Yunokawa, Mayu; Shimizu, Chikako; Hasegawa, Koki; Kanayama, Yousuke; Nozaki, Satoshi; Kinoshita, Takayuki; Wada, Yasuhiro; Tazawa, Shusaku; Takahashi, Kazuhiro; Watanabe, Yasuyoshi; Fujiwara, Yasuhiro

    2013-11-01

    The purpose of this study was to determine the safety, distribution, internal dosimetry, and initial human epidermal growth factor receptor 2 (HER2)-positive tumor images of (64)Cu-DOTA-trastuzumab in humans. PET was performed on 6 patients with primary or metastatic HER2-positive breast cancer at 1, 24, and 48 h after injection of approximately 130 MBq of the probe (64)Cu-DOTA-trastuzumab. Radioactivity data were collected from the blood, urine, and normal-tissue samples of these 6 patients, and the multiorgan biodistribution and internal dosimetry of the probe were evaluated. Safety data were collected for all the patients after the administration of (64)Cu-DOTA-trastuzumab and during the 1-wk follow-up period. According to our results, the best timing for the assessment of (64)Cu-DOTA-trastuzumab uptake by the tumor was 48 h after injection. Radiation exposure during (64)Cu-DOTA-trastuzumab PET was equivalent to that during conventional (18)F-FDG PET. The radioactivity in the blood was high, but uptake of (64)Cu-DOTA-trastuzumab in normal tissues was low. In 2 patients, (64)Cu-DOTA-trastuzumab PET showed brain metastases, indicative of blood-brain barrier disruptions. In 3 patients, (64)Cu-DOTA-trastuzumab PET imaging also revealed primary breast tumors at the lesion sites initially identified by CT. The findings of this study indicated that (64)Cu-DOTA-trastuzumab PET is feasible for the identification of HER2-positive lesions in patients with primary and metastatic breast cancer. The dosimetry and pharmacologic safety results were acceptable at the dose required for adequate PET imaging.

  7. Optimization of conventional X-ray images for the detection of hook of hamate fractures; Optimierung von konventionellen Roentgenaufnahmen zur Erkennung von Hamulus ossis hamati Frakturen

    Energy Technology Data Exchange (ETDEWEB)

    Andresen, R.; Adam, C. [Abt. fuer Bildgebende Diagnostik und Interventionelle Radiologie, KMG Klinikum Guestrow, Akademisches Lehrkrankenhaus der Univ. Rostock, Guestrow (Germany); Radmer, S. [Abt. fuer Orthopaedie und Rheumachirurgie, Immanuel Krankenhaus, Akademisches Lehrkrankenhaus der FU-Berlin (Germany); Scheufler, O. [Abt. fuer Plastische, Rekonstruktive und Aesthetische Chirurgie, Universitaetsspital Basel (Switzerland); Bogusch, G. [Inst. fuer Anatomie des Universitaetsklinikums Charite, Humboldt Univ. zu Berlin (Germany)

    2006-07-01

    Fractures of the hook of the hamate are a rare event. The fracture cannot always be detected clinically and standard radiographs do not always provide an overlap-free image of the hook of the hamate, so that fractures can easily be overlooked. The objective of the present study was to examine if the sensitivity of detecting hamulus ossis hamati fractures can further be improved by a modified conventional radiographic projection. After dissection of the hook of the hamate on 10 cadaver hands, a fracture was produced close to the base using a surgical chisel. Conventional radiographs were then performed in four different projections (dorso-palmar, lateral, carpal-tunnel and oblique view). The oblique view was obtained in a 45 supination position, slight extension and radial duction, with the tube tilted from distal to proximal by 30 . An axial spiral CT was used as a reference for detection of the fracture. The highest sensitivity of the conventional radiographs, with 8/10 identified fractures (80%), was achieved by the oblique view. The carpal-tunnel view with 4/10 (40%) and the dorso-palmar projection with 3/10 (30%) were much lower. All fractures were missed in the lateral projection. If all of the conventional radiographic projections are taken into account, the sensitivity is increased to 90%. All of the fractures were reliably detected in the axial CT-image. If a hamulus ossis hamati fracture is suspected clinically, in addition to the dorso-palmar and carpal-tunnel view, the special oblique view described here should be performed as a third projection plane, while the lateral view can be dispensed with. However, even if all projections are taken into account, a negative finding in the conventional radiographic imaging does not exclude a fracture with absolute certainty. In such cases, a CT or MRI should be performed to exclude a fracture. (orig.)

  8. Challenges and Strategies to Develop a Positive Image of the Library

    Directory of Open Access Journals (Sweden)

    Anisa Sri Restanti

    2018-01-01

    Full Text Available Information technology has been used in the management of the library. There are several libraries have been integrated with the internet to provide services. But the library still image as an institution or an old building that contains the bookshelves and librarian profession under other professions. This article is presented to determine some of the challenges and strategies that can be done in fostering a positive image of the library. Based on the literature study and observation, it’s known, that the challenges are differences in educational background librarians, foster a positive image has not been planned, the development of information technology, the implementation of the code of ethics of librarians is not maximal. In the face of the challenges in creating a positive image, there are strategies that can be done that in terms of internal and external libraries. Thus, it can be concluded that, to foster a positive image of the library is needed strategies and synergies as well as the responsibility of all aspects of the library. Recommendation for librarians are important to develop personal branding. Furthermore, for the library after successfully building a positive image should be able to maintain and restore the image when a crisis.

  9. Challenges and Strategies to Develop a Positive Image of the Library

    Directory of Open Access Journals (Sweden)

    Anisa Sri Restanti

    2017-01-01

    Full Text Available Information technology has been used in the management of the library. There are several libraries have been integrated with the internet to provide services. But the library still image as an institution or an old building that contains the bookshelves and librarian profession under other professions. This article is presented to determine some of the challenges and strategies that can be done in fostering a positive image of the library. Based on the literature study and observation, its known, that the challenges are differences in educational background librarians, foster a positive image has not been planned, the development of information technology, the implementation of the code of ethics of librarians is not maximal. In the face of the challenges in creating a positive image, there are strategies that can be done that in terms of internal and external libraries. Thus, it can be concluded that, to foster a positive image of the library is needed strategies and synergies as well as the responsibility of all aspects of the library. Recommendation for librarians are important to develop personal branding. Furthermore, for the library after successfully building a positive image should be able to maintain and restore the image when a crisis.

  10. Cochlear Implant Electrode Localization Using an Ultra-High Resolution Scan Mode on Conventional 64-Slice and New Generation 192-Slice Multi-Detector Computed Tomography.

    Science.gov (United States)

    Carlson, Matthew L; Leng, Shuai; Diehn, Felix E; Witte, Robert J; Krecke, Karl N; Grimes, Josh; Koeller, Kelly K; Bruesewitz, Michael R; McCollough, Cynthia H; Lane, John I

    2017-08-01

    A new generation 192-slice multi-detector computed tomography (MDCT) clinical scanner provides enhanced image quality and superior electrode localization over conventional MDCT. Currently, accurate and reliable cochlear implant electrode localization using conventional MDCT scanners remains elusive. Eight fresh-frozen cadaveric temporal bones were implanted with full-length cochlear implant electrodes. Specimens were subsequently scanned with conventional 64-slice and new generation 192-slice MDCT scanners utilizing ultra-high resolution modes. Additionally, all specimens were scanned with micro-CT to provide a reference criterion for electrode position. Images were reconstructed according to routine temporal bone clinical protocols. Three neuroradiologists, blinded to scanner type, reviewed images independently to assess resolution of individual electrodes, scalar localization, and severity of image artifact. Serving as the reference standard, micro-CT identified scalar crossover in one specimen; imaging of all remaining cochleae demonstrated complete scala tympani insertions. The 192-slice MDCT scanner exhibited improved resolution of individual electrodes (p implant imaging compared with conventional MDCT. This technology provides important feedback regarding electrode position and course, which may help in future optimization of surgical technique and electrode design.

  11. 2D XD-GRASP provides better image quality than conventional 2D cardiac cine MRI for patients who cannot suspend respiration

    Science.gov (United States)

    Piekarski, Eve; Chitiboi, Teodora; Ramb, Rebecca; Latson, Larry A; Bhatla, Puneet; Feng, Li; Axel, Leon

    2017-01-01

    Object Residual respiratory motion degrades image quality in conventional cardiac cine MRI (CCMR). We evaluated whether a free-breathing (FB) radial imaging CCMR sequence with compressed sensing reconstruction (eXtra-Dimension (e.g. cardiac and respiratory phases) Golden-angle RAdial Sparse Parallel, or XD-GRASP) could provide better image quality than a conventional Cartesian breath-held (BH) sequence, in an unselected population of patients undergoing clinical CCMR. Material and Methods 101 patients who underwent BH and FB imaging in a mid-ventricular short-axis plane at a matching location were included. Visual and quantitative image analysis was performed by two blinded experienced readers, using a 5-point qualitative scale to score overall image quality and visual signal-to-noise ratio (SNR) grade, with measures of noise and sharpness. End-diastole (ED) and end-systole (ES) left-ventricular areas were also measured and compared for both BH and FB images. Results Image quality was generally better with the BH cines (overall quality grade BH vs FB: 4 vs 2.9, pXD-GRASP CCMR was visually inferior to conventional BH cardiac cine in general, it provided improved image quality in the subgroup of patients presenting respiratory motion-induced artifacts on breath-held images. PMID:29067539

  12. Nuclear myocardial perfusion imaging using thallium-201 with a novel multifocal collimator SPECT/CT: IQ-SPECT versus conventional protocols in normal subjects.

    Science.gov (United States)

    Matsuo, Shinro; Nakajima, Kenichi; Onoguchi, Masahisa; Wakabayash, Hiroshi; Okuda, Koichi; Kinuya, Seigo

    2015-06-01

    A novel multifocal collimator, IQ-SPECT (Siemens) consists of SMARTZOOM, cardio-centric and 3D iterative SPECT reconstruction and makes it possible to perform MPI scans in a short time. The aims are to delineate the normal uptake in thallium-201 ((201)Tl) SPECT in each acquisition method and to compare the distribution between new and conventional protocol, especially in patients with normal imaging. Forty patients (eight women, mean age of 75 years) who underwent myocardial perfusion imaging were included in the study. All patients underwent one-day protocol perfusion scan after an adenosine-stress test and at rest after administering (201)Tl and showed normal results. Acquisition was performed on a Symbia T6 equipped with a conventional dual-headed gamma camera system (Siemens ECAM) and with a multifocal SMARTZOOM collimator. Imaging was performed with a conventional system followed by IQ-SPECT/computed tomography (CT). Reconstruction was performed with or without X-ray CT-derived attenuation correction (AC). Two nuclear physicians blinded to clinical information interpreted all myocardial perfusion images. A semi-quantitative myocardial perfusion was analyzed by a 17-segment model with a 5-point visual scoring. The uptake of each segment was measured and left ventricular functions were analyzed by QPS software. IQ-SPECT provided good or excellent image quality. The quality of IQ-SPECT images without AC was similar to those of conventional LEHR study. Mid-inferior defect score (0.3 ± 0.5) in the conventional LEHR study was increased significantly in IQ-SPECT with AC (0 ± 0). IQ-SPECT with AC improved the mid-inferior decreased perfusion shown in conventional images. The apical tracer count in IQ-SPECT with AC was decreased compared to that in LEHR (0.1 ± 0.3 vs. 0.5 ± 0.7, p IQ-SPECT was significantly higher than that from the LEHR collimator (p = 0.0009). The images of IQ-SPECT acquired in a short time are equivalent to that of conventional LEHR

  13. New patient-controlled abdominal compression method in radiography: radiation dose and image quality.

    Science.gov (United States)

    Piippo-Huotari, Oili; Norrman, Eva; Anderzén-Carlsson, Agneta; Geijer, Håkan

    2018-05-01

    The radiation dose for patients can be reduced with many methods and one way is to use abdominal compression. In this study, the radiation dose and image quality for a new patient-controlled compression device were compared with conventional compression and compression in the prone position . To compare radiation dose and image quality of patient-controlled compression compared with conventional and prone compression in general radiography. An experimental design with quantitative approach. After obtaining the approval of the ethics committee, a consecutive sample of 48 patients was examined with the standard clinical urography protocol. The radiation doses were measured as dose-area product and analyzed with a paired t-test. The image quality was evaluated by visual grading analysis. Four radiologists evaluated each image individually by scoring nine criteria modified from the European quality criteria for diagnostic radiographic images. There was no significant difference in radiation dose or image quality between conventional and patient-controlled compression. Prone position resulted in both higher dose and inferior image quality. Patient-controlled compression gave similar dose levels as conventional compression and lower than prone compression. Image quality was similar with both patient-controlled and conventional compression and was judged to be better than in the prone position.

  14. A multileaf collimator field prescription preparation system for conventional radiotherapy

    International Nuclear Information System (INIS)

    Du, M.N.; Yu, C. X.; Symons, M.; Yan, D.; Taylor, R.; Matter, R.C.; Gustafson, G.; Martinez, A.; Wong, J.W.

    1995-01-01

    Purpose: The purpose of this work is to develop a prescription preparation system for efficient field shaping using a multileaf collimator that can be used in community settings as well as research institutions. The efficiency advantage of the computer-controlled multileaf collimator, over cerrobend blocks, to shape radiation fields has been shown in conformal treatments, which typically require complete volumetric computerized tomographic data for three-dimensional radiation treatment planning--a utility not readily available to the general community. As a result, most patients today are treated with conventional radiation therapy. Therefore, we believe that it is very important to fully use the same efficiency advantage of multileaf collimator as a block replacement in conventional practice. Methods and Material: The multileaf collimator prescription preparation system developed by us acquires prescription images from different sources, including film scanner and radiation treatment planning systems. The multileaf collimator angle and leaf positions are set from the desired field contour defined on the prescription image, by minimizing the area discrepancies. Interactive graphical tools include manual adjustment of collimator angle and leaf positions, and definition of portions of the field edges that require maximal conformation. Data files of the final leaf positions are transferred to the multileaf collimator controller via a dedicated communication link. Results: We have implemented the field prescription preparation system and a network model for integrating the multileaf collimator and other radiotherapy modalities for routine treatments. For routine plan evaluation, isodose contours measured with film in solid water phantom at prescription depth are overlaid on the prescription image. Preliminary study indicates that the efficiency advantage of the MLC over cerrobend blocks in conformal therapy also holds true for conventional treatments. Conclusion: Our

  15. Patient positioning method based on binary image correlation between two edge images for proton-beam radiation therapy

    International Nuclear Information System (INIS)

    Sawada, Akira; Yoda, Kiyoshi; Numano, Masumi; Futami, Yasuyuki; Yamashita, Haruo; Murayama, Shigeyuki; Tsugami, Hironobu

    2005-01-01

    A new technique based on normalized binary image correlation between two edge images has been proposed for positioning proton-beam radiotherapy patients. A Canny edge detector was used to extract two edge images from a reference x-ray image and a test x-ray image of a patient before positioning. While translating and rotating the edged test image, the absolute value of the normalized binary image correlation between the two edge images is iteratively maximized. Each time before rotation, dilation is applied to the edged test image to avoid a steep reduction of the image correlation. To evaluate robustness of the proposed method, a simulation has been carried out using 240 simulated edged head front-view images extracted from a reference image by varying parameters of the Canny algorithm with a given range of rotation angles and translation amounts in x and y directions. It was shown that resulting registration errors have an accuracy of one pixel in x and y directions and zero degrees in rotation, even when the number of edge pixels significantly differs between the edged reference image and the edged simulation image. Subsequently, positioning experiments using several sets of head, lung, and hip data have been performed. We have observed that the differences of translation and rotation between manual positioning and the proposed method were within one pixel in translation and one degree in rotation. From the results of the validation study, it can be concluded that a significant reduction in workload for the physicians and technicians can be achieved with this method

  16. Detection of Staphylococcus aureus among coagulase positive staphylococci from animal origin based on conventional and molecular methods

    Directory of Open Access Journals (Sweden)

    Nikolina Velizarova Rusenova

    2017-03-01

    Full Text Available The present study aimed to detect Staphylococcus aureus (S. aureus among other coagulase positive staphylococci from animal origin by using conventional methods (biochemical tests and latex agglutination and a molecular method, based on the nuc gene, as the gold standard and to assess the usefulness of these methods. For this purpose, total of 344 staphylococcal isolates were collected and analysed. A total of 156 isolates suspicious for S. aureus were detected by a conventional biochemical method – 88 from cows, 18 from goats, 7 from pigs, 17 from poultry, 7 from rabbits and 19 from dogs. The majority of S. aureus strains gave typical biochemical reactions with the exception of 30 (19.2% and 25 (16% that were VP negative and weak positive in fermenting mannitol, respectively. Twelve strains were found to be non-haemolytic (7.7% and four strains did not ferment trehalose (2.6%. Other staphylococci were identified as S. pseudintermedius (n = 103, S. hyicus (n = 23 and the rest were coagulase-negative staphylococci. Latex agglutination test resulted in rapid positive reactions with S. aureus with exception of 5 strains (3.2% from cow mastitis milk. Positive agglutination reactions were also established with S. pseudintermedius, and S. hyicus. PCR confirmed all strains that were preliminary identified as S. aureus by amplification of 270 bp fragment of nuc gene specific for this species. The atypical reactions in certain strains established in this study have shown that the precise detection of S. aureus from animal origin should be done by combination of conventional and molecular methods.

  17. Yoga and positive body image: A test of the Embodiment Model.

    Science.gov (United States)

    Mahlo, Leeann; Tiggemann, Marika

    2016-09-01

    The study aimed to test the Embodiment Model of Positive Body Image (Menzel & Levine, 2011) within the context of yoga. Participants were 193 yoga practitioners (124 Iyengar, 69 Bikram) and 127 university students (non-yoga participants) from Adelaide, South Australia. Participants completed questionnaire measures of positive body image, embodiment, self-objectification, and desire for thinness. Results showed yoga practitioners scored higher on positive body image and embodiment, and lower on self-objectification than non-yoga participants. In support of the embodiment model, the relationship between yoga participation and positive body image was serially mediated by embodiment and reduced self-objectification. Although Bikram practitioners endorsed appearance-related reasons for participating in yoga more than Iyengar practitioners, there were no significant differences between Iyengar and Bikram yoga practitioners on body image variables. It was concluded that yoga is an embodying activity that can provide women with the opportunity to cultivate a favourable relationship with their body. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Evaluation of accuracy in target positions of multmodality imaging using brain phantom

    Energy Technology Data Exchange (ETDEWEB)

    Juh, R. H.; Suh, T. S.; Chung, Y. A. [The Catholic University of Korea, Seoul (Korea, Republic of)

    2002-07-01

    Determination of target positions in radiation therapy or radiosurgery is critical to the successful treatment. It is often difficult to recognize the target position only from single image modality since each image modality has unique image pattern and image distortion problem. The purpose of this study is to evaluate the accuracy of target positions with multimodality brain phantom. We obtained CT, MR, and SPECT scan images with the specially designed brain phantom. Brain phantom consists of brain for images and frame for localization. The phantom was a water fillable cylinder containing 58 axial layers of 2.0 mm thickness. Each layer allows water to permeate various regions to match gray matter to white matter of 1:1 ratio. Localization frame with 5mm inner diameter and 150/160 mm length were attached to the outside of the brain slice and inside of the phantom cylinder. The phantom was filled with 0.16 M CuSO{sub 4} solution for MRI scan, and distilled water for CT and 15mCi (555 MBq) Tc-99m for SPECT. Axial slice images and volume images including the targets and localizer were obtained for each modality. To evaluate the errors in target positions, the position of localization and target balls measured in SPECT were compared with MR and CT. Transformation parameters for translation, rotation and scaling were determined by surface matching each SPECT with MR and CT images. Multimodality phantom was very useful to evaluate the accuracy of target positions among the different types of image modality such as CT, MR and SPECT.

  19. Method for position emission mammography image reconstruction

    Science.gov (United States)

    Smith, Mark Frederick

    2004-10-12

    An image reconstruction method comprising accepting coincidence datat from either a data file or in real time from a pair of detector heads, culling event data that is outside a desired energy range, optionally saving the desired data for each detector position or for each pair of detector pixels on the two detector heads, and then reconstructing the image either by backprojection image reconstruction or by iterative image reconstruction. In the backprojection image reconstruction mode, rays are traced between centers of lines of response (LOR's), counts are then either allocated by nearest pixel interpolation or allocated by an overlap method and then corrected for geometric effects and attenuation and the data file updated. If the iterative image reconstruction option is selected, one implementation is to compute a grid Siddon retracing, and to perform maximum likelihood expectation maiximization (MLEM) computed by either: a) tracing parallel rays between subpixels on opposite detector heads; or b) tracing rays between randomized endpoint locations on opposite detector heads.

  20. Comparison between conventional MR arthrograhphy and abduction and external rotation MR arthrography in revealing tears of the antero-inferior glenoid labrum

    International Nuclear Information System (INIS)

    Choi, Jung Ah; Suh, Sang Il; Kim, Baek Hyun; Cha, Sang Hoon; Kim, Myung Gyu; Lee, Ki Yeol; Lee, Chang Hee

    2001-01-01

    To compare, in terms of their demonstration of tears of the anterior glenoid labrum, oblique axial MR arthrography obtained with the patient's shoulder in the abduction and external rotation (ABER) position, with conventional axial MR arthrography obtained with the patient's arm in the neutral position. MR arthrography of the shoulder, including additional oblique axial sequences with the patient in the ABER position, was performed in 30 patients with a clinical history of recurrent anterior shoulder dislocation. The degree of anterior glenoid labral tear or defect was evaluated in both the conventional axial and the ABER position by two radiologists. Decisions were reached by consensus, and a three-point scale was used: grade 1=normal; grade 2=probable tear, diagnosed when subtle increased signal intensity in the labrum was apparent; grade 3=definite tear/defect, when a contrast material-filled gap between the labrum and the glenoid rim or deficient labrum was present. The scores for each imaging sequence were averaged and to compare conventional axial and ABER position scans, Student's t test was performed. In 21 (70%) of 30 patients, the same degree of anterior instability was revealed by both imaging sequences. Eight (27%) had a lower grade in the axial position than in the ABER position, while one (3%) had a higher grade in the axial position. Three whose axial scan was grade 1 showed only equivocal evidence of tearing, but their ABER-position scan, in which a contrast material-filled gap between the labrum and the glenoid rim was present, was grade 3. The average grade was 2.5 (SD=0.73) for axial scans and 2.8 (SD=0.46) for the ABER position. The difference between axial and ABER-position scans was statistically significant (p<0.05). MR arthrography with the patient's shoulder in the ABER position is more efficient than conventional axial scanning in revealing the degree of tear or defect of the anterior glenoid labrum. When equivocal features are seen at

  1. Evaluation of multimodality imaging using image fusion with ultrasound tissue elasticity imaging in an experimental animal model.

    Science.gov (United States)

    Paprottka, P M; Zengel, P; Cyran, C C; Ingrisch, M; Nikolaou, K; Reiser, M F; Clevert, D A

    2014-01-01

    To evaluate the ultrasound tissue elasticity imaging by comparison to multimodality imaging using image fusion with Magnetic Resonance Imaging (MRI) and conventional grey scale imaging with additional elasticity-ultrasound in an experimental small-animal-squamous-cell carcinoma-model for the assessment of tissue morphology. Human hypopharynx carcinoma cells were subcutaneously injected into the left flank of 12 female athymic nude rats. After 10 days (SD ± 2) of subcutaneous tumor growth, sonographic grey scale including elasticity imaging and MRI measurements were performed using a high-end ultrasound system and a 3T MR. For image fusion the contrast-enhanced MRI DICOM data set was uploaded in the ultrasonic device which has a magnetic field generator, a linear array transducer (6-15 MHz) and a dedicated software package (GE Logic E9), that can detect transducers by means of a positioning system. Conventional grey scale and elasticity imaging were integrated in the image fusion examination. After successful registration and image fusion the registered MR-images were simultaneously shown with the respective ultrasound sectional plane. Data evaluation was performed using the digitally stored video sequence data sets by two experienced radiologist using a modified Tsukuba Elasticity score. The colors "red and green" are assigned for an area of soft tissue, "blue" indicates hard tissue. In all cases a successful image fusion and plan registration with MRI and ultrasound imaging including grey scale and elasticity imaging was possible. The mean tumor volume based on caliper measurements in 3 dimensions was ~323 mm3. 4/12 rats were evaluated with Score I, 5/12 rates were evaluated with Score II, 3/12 rates were evaluated with Score III. There was a close correlation in the fused MRI with existing small necrosis in the tumor. None of the scored II or III lesions was visible by conventional grey scale. The comparison of ultrasound tissue elasticity imaging enables a

  2. Correlation of conventional simulation x-ray films and CT images for HDR-brachytherapy catheters reconstruction

    International Nuclear Information System (INIS)

    Rajendran, M.; Reddy, K.D.; Reddy, R.M.; Reddy, J.M.; Reddy, B.V.N.; Kiran Kumar; Gopi, S.; Dharaniraj; Janardhanan

    2002-01-01

    In order to plan a brachytherapy implant, it is imperative that implant reconstruction is done accurately. The purpose of this paper is to evaluate whether implant reconstruction done with transverse CT images is comparable to reconstruction done with conventional x-ray films

  3. Study of two novel large-field-of-view image intensifiers versus conventional chest radiography with use of FROC methods and simulated pulmonary nodules

    International Nuclear Information System (INIS)

    Winter, L.H.L.; Chakraborty, D.P.; Van Waes, P.F.G.M.; Puylaert, C.B.A.J.

    1989-01-01

    Two novel large-field-of-view image intensifier (LFOV 1.1) tubes have been introduced whose image area makes them suitable for chest imaging. Both modalities present a 100-mm hard-copy image to the radiologist. A pulmonary nodule performance experiment was done to compare the diagnostic accuracy of these tubes with conventional full-size chest images. The data were analyzed with the maximum-likelihood FROCFIT program. The relative ranking in terms of decreasing A1 values was TLX, Siemens 43-cm mode, conventional radiography, and Siemens 57-cm mode

  4. SU-E-I-39: Combining Conventional Tomographic Imaging Strategy and Interior Tomography for Low Dose Dual-Energy CT (DECT)

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Q [School of Electronic and Information Engineering, Xi’an Jiaotong University, Xi’an, Shaanxi 710049 (China); Department of Radiation Oncology, Stanford University, Stanford, CA (United States); Xing, L [Department of Radiation Oncology, Stanford University, Stanford, CA (United States); Xiong, G; Elmore, K; Min, J [Dalio Institute of Cardiovascular Imaging, New York- Presbyterian Hospital and Weill Cornell Medical College, New York, NY (United States)

    2015-06-15

    Purpose: Dual-energy CT (DECT) affords quantitative information of tissue density and provides a new dimension for disease diagnosis and treatment planning. The technique, however, increases the imaging dose because of the doubled scans, and thus hinders its widespread clinical applications. The purpose of this work is to develop a novel hybrid DECT image acquisition and reconstruction strategy, in which one of the energies is dealt by interior tomography while the other one is obtained using conventional tomography approach. Methods: In the proposed hybrid imaging strategy, the projection data of one of the energies (e.g., high-energy) were acquired and processed in an interior scanning model, whereas the other energy in the conventional tomographic approach. It known that, if the ROI is piecewise constant or polynomial, the interior ROI can be reconstructed with TV or HOT minimization. Here we extend the TV based interior reconstruction method into dual-energy situation. The ROI images so obtained were overlaid in the context of conventional CT of the companion energy. A material based composition in ROI was used in the proposed reconstruction framework. Results: In the simulation experiment with a diagnostic DECT geometry and energies, we were able to derive the densities of soft-tissues and bones in the ROI with high fidelity. In the experimental CBCT study, both kV and MV data were collected using the on-board kV and MV imaging system. The MV data were truncated only across the ROI. Using the interior tomography reconstruction above, we were able to obtain the ROI images as that obtained using un-truncated MV data with known tissue densities. Conclusion: The proposed DECT imaging strategy provides an effective way to extract tissue density information in the ROI and in the context of anatomical images of CT imaging, with much reduced imaging dose.

  5. Image Positioning Accuracy Analysis for Super Low Altitude Remote Sensing Satellites

    Directory of Open Access Journals (Sweden)

    Ming Xu

    2012-10-01

    Full Text Available Super low altitude remote sensing satellites maintain lower flight altitudes by means of ion propulsion in order to improve image resolution and positioning accuracy. The use of engineering data in design for achieving image positioning accuracy is discussed in this paper based on the principles of the photogrammetry theory. The exact line-of-sight rebuilding of each detection element and this direction precisely intersecting with the Earth's elliptical when the camera on the satellite is imaging are both ensured by the combined design of key parameters. These parameters include: orbit determination accuracy, attitude determination accuracy, camera exposure time, accurately synchronizing the reception of ephemeris with attitude data, geometric calibration and precise orbit verification. Precise simulation calculations show that image positioning accuracy of super low altitude remote sensing satellites is not obviously improved. The attitude determination error of a satellite still restricts its positioning accuracy.

  6. Position Estimation and Local Mapping Using Omnidirectional Images and Global Appearance Descriptors

    Directory of Open Access Journals (Sweden)

    Yerai Berenguer

    2015-10-01

    Full Text Available This work presents some methods to create local maps and to estimate the position of a mobile robot, using the global appearance of omnidirectional images. We use a robot that carries an omnidirectional vision system on it. Every omnidirectional image acquired by the robot is described only with one global appearance descriptor, based on the Radon transform. In the work presented in this paper, two different possibilities have been considered. In the first one, we assume the existence of a map previously built composed of omnidirectional images that have been captured from previously-known positions. The purpose in this case consists of estimating the nearest position of the map to the current position of the robot, making use of the visual information acquired by the robot from its current (unknown position. In the second one, we assume that we have a model of the environment composed of omnidirectional images, but with no information about the location of where the images were acquired. The purpose in this case consists of building a local map and estimating the position of the robot within this map. Both methods are tested with different databases (including virtual and real images taking into consideration the changes of the position of different objects in the environment, different lighting conditions and occlusions. The results show the effectiveness and the robustness of both methods.

  7. Evaluation of the tarsometatarsal joint using conventional radiography, CT, and MR imaging.

    Science.gov (United States)

    Siddiqui, Nasir A; Galizia, Mauricio S; Almusa, Emad; Omar, Imran M

    2014-01-01

    The tarsometatarsal, or Lisfranc, joint complex provides stability to the midfoot and forefoot through intricate osseous relationships between the distal tarsal bones and metatarsal bases and their connections with stabilizing ligamentous support structures. Lisfranc joint injuries are relatively uncommon, and their imaging findings can be subtle. These injuries have typically been divided into high-impact fracture-displacements, which are often seen after motor vehicle collisions, and low-impact midfoot sprains, which are more commonly seen in athletes. The injury mechanism often influences the imaging findings, and classification systems based primarily on imaging features have been developed to help diagnose and treat these injuries. Patients may have significant regional swelling and pain that prevent thorough physical examination or may have other more critical injuries at initial posttrauma evaluation. These factors may cause diagnostic delays and lead to subsequent morbidities, such as midfoot instability, deformity, and debilitating osteoarthritis. Missed Lisfranc ligament injuries are among the most common causes of litigation against radiologists and emergency department physicians. Radiologists must understand the pathophysiology of these injuries and the patterns of imaging findings seen at conventional radiography, computed tomography, and magnetic resonance imaging to improve injury detection and obtain additional information for referring physicians that may affect the selection of the injury classification system, treatment, and prognosis. ©RSNA, 2014.

  8. Supine spinal magnetic resonance imaging with straightened lower extremities in spondylolisthesis: A comparison with the conventional technique

    International Nuclear Information System (INIS)

    Daghighi, Mohammad Hossein; Poureisa, Masoud; Arablou, Farid; Fouladi, Daniel F.

    2015-01-01

    Highlights: • MR imaging with straightened lower extremities was tested in spondylolisthesis. • This technique is more accurate than conventional MR imaging in detecting slip. • Level of spondylolisthesis is the only independent predictor of severity of slip. - Abstract: Objectives: To compare the degree of slip in spondylolisthesis on supine magnetic resonance (MR) images obtained with flexed and straightened lower extremities. Methods: Supine spinal MR studies were performed in 100 cases of symptomatic spondylolisthesis with flexed and then straightened lower extremities. The angle of lumbar lordosis (by Cobb's method) and the degree of slip (by Taillard's method) were compared between the two sets of images. Results: The mean angle of lumbar lordosis increased from 51.65 ± 8.57° on MR images with flexed lower limbs to 57.39 ± 9.05° on MR images with straightened lower limbs (p < 0.001; mean percent increase: 11.51%). Similar change was also observed for the mean degree of slip (from 25.80 ± 7.74% to 28.68 ± 7.93%, p < 0.001; mean percent increase: 12.60%). After MR imaging with straightened lower extremities 22 out of 54 initially grade I cases had grade II disease (p < 0.001). Conclusions: Supine magnetic resonance imaging with straightened lower extremities detects higher degree of slippage in symptomatic patients with spondylolisthesis compared to conventional MRI with flexed lower extremities

  9. Supine spinal magnetic resonance imaging with straightened lower extremities in spondylolisthesis: A comparison with the conventional technique

    Energy Technology Data Exchange (ETDEWEB)

    Daghighi, Mohammad Hossein; Poureisa, Masoud; Arablou, Farid [Department of Radiology, Imam Reza Teaching Center, Tabriz University of Medical Sciences, Tabriz (Iran, Islamic Republic of); Fouladi, Daniel F., E-mail: medicorelax@yahoo.com [Drug Applied Research Center, Tabriz University of Medical Sciences, Tabriz (Iran, Islamic Republic of)

    2015-05-15

    Highlights: • MR imaging with straightened lower extremities was tested in spondylolisthesis. • This technique is more accurate than conventional MR imaging in detecting slip. • Level of spondylolisthesis is the only independent predictor of severity of slip. - Abstract: Objectives: To compare the degree of slip in spondylolisthesis on supine magnetic resonance (MR) images obtained with flexed and straightened lower extremities. Methods: Supine spinal MR studies were performed in 100 cases of symptomatic spondylolisthesis with flexed and then straightened lower extremities. The angle of lumbar lordosis (by Cobb's method) and the degree of slip (by Taillard's method) were compared between the two sets of images. Results: The mean angle of lumbar lordosis increased from 51.65 ± 8.57° on MR images with flexed lower limbs to 57.39 ± 9.05° on MR images with straightened lower limbs (p < 0.001; mean percent increase: 11.51%). Similar change was also observed for the mean degree of slip (from 25.80 ± 7.74% to 28.68 ± 7.93%, p < 0.001; mean percent increase: 12.60%). After MR imaging with straightened lower extremities 22 out of 54 initially grade I cases had grade II disease (p < 0.001). Conclusions: Supine magnetic resonance imaging with straightened lower extremities detects higher degree of slippage in symptomatic patients with spondylolisthesis compared to conventional MRI with flexed lower extremities.

  10. Prospective Evaluation of 68Ga-RM2 PET/MRI in Patients with Biochemical Recurrence of Prostate Cancer and Negative Findings on Conventional Imaging.

    Science.gov (United States)

    Minamimoto, Ryogo; Sonni, Ida; Hancock, Steven; Vasanawala, Shreyas; Loening, Andreas; Gambhir, Sanjiv S; Iagaru, Andrei

    2018-05-01

    68 Ga-labeled DOTA-4-amino-1-carboxymethyl-piperidine-d-Phe-Gln-Trp-Ala-Val-Gly-His-Sta-Leu-NH 2 ( 68 Ga-RM2) is a synthetic bombesin receptor antagonist that targets gastrin-releasing peptide receptor (GRPr). GRPr proteins are highly overexpressed in several human tumors, including prostate cancer (PCa). We present data from the use of 68 Ga-RM2 in patients with biochemical recurrence (BCR) of PCa and negative findings on conventional imaging. Methods: We enrolled 32 men with BCR of PCa, who were 59-83 y old (mean ± SD, 68.7 ± 6.4 y). Imaging started at 40-69 min (mean, 50.5 ± 6.8 min) after injection of 133.2-151.7 MBq (mean, 140.6 ± 7.4 MBq) of 68 Ga-RM2 using a time-of-flight-enabled simultaneous PET/MRI scanner. T1-weighted, T2-weighted, and diffusion-weighted images were acquired. Results: All patients had a rising level of prostate-specific antigen (PSA) (range, 0.3-119.0 ng/mL; mean, 10.1 ± 21.3 ng/mL) and negative findings on conventional imaging (CT or MRI, and a 99m Tc-methylene diphosphonate bone scan) before enrollment. The observed 68 Ga-RM2 PET detection rate was 71.8%. 68 Ga-RM2 PET identified recurrent PCa in 23 of the 32 participants, whereas the simultaneous MRI scan identified findings compatible with recurrent PCa in 11 of the 32 patients. PSA velocity was 0.32 ± 0.59 ng/mL/y (range, 0.04-1.9 ng/mL/y) in patients with negative PET findings and 2.51 ± 2.16 ng/mL/y (range, 0.13-8.68 ng/mL/y) in patients with positive PET findings ( P = 0.006). Conclusion: 68 Ga-RM2 PET can be used for assessment of GRPr expression in patients with BCR of PCa. High uptake in multiple areas compatible with cancer lesions suggests that 68 Ga-RM2 is a promising PET radiopharmaceutical for localization of disease in patients with BCR of PCa and negative findings on conventional imaging. © 2018 by the Society of Nuclear Medicine and Molecular Imaging.

  11. Determination of fat and total protein content in milk using conventional digital imaging

    DEFF Research Database (Denmark)

    Kucheryavskiy, Sergey; Melenteva, Anastasiia; Bogomolov, Andrey

    2014-01-01

    into account spatial distribution of light, diffusely transmitted through a sample. The proposed method has been tested on two sample sets prepared from industrial raw milk standards, with variable fat and protein content. Partial Least-Squares (PLS) regression on the features calculated from images......The applicability of conventional digital imaging to quantitative determination of fat and total protein in cow’s milk, based on the phenomenon of light scatter, has been proved. A new algorithm for extracting features from digital images of milk samples has been developed. The algorithm takes...... of monochromatically illuminated milk samples resulted in models with high prediction performance when analysed the sets separately (best models with cross-validated R2=0.974 for protein and R2=0.973 for fat content). However when analysed the sets jointly the obtained results were significantly worse (best models...

  12. Residents’ perceptions of convention centres: A distance decay analysis

    OpenAIRE

    Li, S; Cang, S; Thomas, R; Hyun, S

    2017-01-01

    Public investment in convention centres represents a relatively common approach to stimulating economic development in many large cities throughout the world. The rationale is that metropolitan authorities can thereby attract business tourists and promote positive (business friendly) images of their locality. While the economic dimension of such spending has received some attention, especially by consultants, there has been little theorising or empirical research which has examined residents’...

  13. Source position error influence on industry CT image quality

    International Nuclear Information System (INIS)

    Cong Peng; Li Zhipeng; Wu Haifeng

    2004-01-01

    Based on the emulational exercise, the influence of source position error on industry CT (ICT) image quality was studied and the valuable parameters were obtained for the design of ICT. The vivid container CT image was also acquired from the CT testing system. (authors)

  14. Diagnostic accuracy of phosphor plate systems and conventional radiography in the detection of simulated internal root resorption.

    Science.gov (United States)

    Vasconcelos, Karla de Faria; Rovaris, Karla; Nascimento, Eduarda Helena Leandro; Oliveira, Matheus Lima; Távora, Débora de Melo; Bóscolo, Frab Norberto

    2017-11-01

    To evaluate the performance of conventional radiography and photostimulable phosphor (PSP) plate in the detection of simulated internal root resorption (IRR) lesions in early stages. Twenty single-rooted teeth were X-rayed before and after having a simulated IRR early lesion. Three imaging systems were used: Kodak InSight dental film and two PSPs digital systems, Digora Optime and VistaScan. The digital images were displayed on a 20.1″ LCD monitor using the native software of each system, and the conventional radiographs were evaluated on a masked light box. Two radiologists were asked to indicate the presence or absence of IRR and, after two weeks, all images were re-evaluated. Cohen's kappa coefficient was calculated to assess intra- and interobserver agreement. The three imaging systems were compared using the Kruskal-Wallis test. For interexaminer agreement, overall kappa values were 0.70, 0.65 and 0.70 for conventional film, Digora Optima and VistaScan, respectively. Both the conventional and digital radiography presented low sensitivity, specificity, accuracy, positive and negative predictive values with no significant difference between imaging systems (p = .0725). The performance of conventional and PSP was similar in the detection of simulated IRR lesions in early stages with low accuracy.

  15. Imaging follow-up in patients with unresectable cellular hepatocarcinoma treated with conventional TACE

    International Nuclear Information System (INIS)

    Dumitru, R.

    2012-01-01

    Full text: Background: Hepatocellular carcinoma (HCC) represents more than 5% of all neoplasms and is the most frequent cause of mortality in patients with cirrhosis. Although a number of therapeutic options are available, transarterial chemoembolisation is widely used in the treatment of unresectable HCC. Aim: Evaluation of the role of CT and MRI exams in the imaging followup of patients with unresectable hepatocellular carcinoma treated with conventional transarterial chemoembolisation (TACE). Materials and methods: We retrospectively reviewed 120 consecutive patients with the diagnosis of HCC, sent to the Department of Radiology, Medical Imaging and Interventional Radiology between january 2011 and april 2012 for TACE. The diagnosis of HCC was established using imaging criteria and elevated alfafetoprotein levels (higher than 400ng/ml) or histologic diagnosis. After the procedure, the imaging followup algorithm consisted in an ultrasound exam 24 hours after the procedure, a CT exam 1 month, a MRI exam 3 months later (if the previous CT showed no tumoral residues) and a CT exam 6 months later. The tumoral response was evaluated using the modified RECIST criteria (tumoral dimensions defined as the product of the 2 largest diameters), the visualisation of tumoral arterial enhancement and the presence of intratumoral lipiodol accumulation (defined as absent, homogenous or heterogenous). Results: At the CT exam performed 1 month after the procedure, 44 patients (37%) had homogenous intratumoral lipiodol accumulation, without any tumoral residues and with dimensional reduction. In patients with tumoral residue (n=76), the intratumoral lipiodol accumulation was homogenous (n=48) or heterogenous (n=28); in 5 cases, after the first TACE procedure, we had no lipiodol accumulation in the target lesion. Conclusion: CT exam is an essential tool in the postprocedural followup in patients with unresectable hepatocellular carcinoma treated with conventional transarterial

  16. Verification of patient position and delivery of IMRT by electronic portal imaging

    International Nuclear Information System (INIS)

    Fielding, Andrew L.; Evans, Philip M.; Clark, Catharine H.

    2004-01-01

    Background and purpose: The purpose of the work presented in this paper was to determine whether patient positioning and delivery errors could be detected using electronic portal images of intensity modulated radiotherapy (IMRT). Patients and methods: We carried out a series of controlled experiments delivering an IMRT beam to a humanoid phantom using both the dynamic and multiple static field method of delivery. The beams were imaged, the images calibrated to remove the IMRT fluence variation and then compared with calibrated images of the reference beams without any delivery or position errors. The first set of experiments involved translating the position of the phantom both laterally and in a superior/inferior direction a distance of 1, 2, 5 and 10 mm. The phantom was also rotated 1 and 2 deg. For the second set of measurements the phantom position was kept fixed and delivery errors were introduced to the beam. The delivery errors took the form of leaf position and segment intensity errors. Results: The method was able to detect shifts in the phantom position of 1 mm, leaf position errors of 2 mm, and dosimetry errors of 10% on a single segment of a 15 segment IMRT step and shoot delivery (significantly less than 1% of the total dose). Conclusions: The results of this work have shown that the method of imaging the IMRT beam and calibrating the images to remove the intensity modulations could be a useful tool in verifying both the patient position and the delivery of the beam

  17. Multiplex Mass Spectrometric Imaging with Polarity Switching for Concurrent Acquisition of Positive and Negative Ion Images

    Science.gov (United States)

    Korte, Andrew R.; Lee, Young Jin

    2013-06-01

    We have recently developed a multiplex mass spectrometry imaging (MSI) method which incorporates high mass resolution imaging and MS/MS and MS3 imaging of several compounds in a single data acquisition utilizing a hybrid linear ion trap-Orbitrap mass spectrometer (Perdian and Lee, Anal. Chem. 82, 9393-9400, 2010). Here we extend this capability to obtain positive and negative ion MS and MS/MS spectra in a single MS imaging experiment through polarity switching within spiral steps of each raster step. This methodology was demonstrated for the analysis of various lipid class compounds in a section of mouse brain. This allows for simultaneous imaging of compounds that are readily ionized in positive mode (e.g., phosphatidylcholines and sphingomyelins) and those that are readily ionized in negative mode (e.g., sulfatides, phosphatidylinositols and phosphatidylserines). MS/MS imaging was also performed for a few compounds in both positive and negative ion mode within the same experimental set-up. Insufficient stabilization time for the Orbitrap high voltage leads to slight deviations in observed masses, but these deviations are systematic and were easily corrected with a two-point calibration to background ions.

  18. Soft tissue masses with myxoid stroma: Can conventional magnetic resonance imaging differentiate benign from malignant tumors?

    Energy Technology Data Exchange (ETDEWEB)

    Crombe, A., E-mail: amandine.crombe@ens-lyon.fr [Department of Radiology, Institut Bergonié, 229 cours de l’Argonne, 33076 Bordeaux Cedex (France); Alberti, N. [Department of Radiology, Institut Bergonié, 229 cours de l’Argonne, 33076 Bordeaux Cedex (France); Stoeckle, E. [Department of Surgery, Institut Bergonié, 229 cours de l’Argonne, 33076 Bordeaux Cedex (France); Brouste, V. [Clinical and Epidemiological Research Unit, Institut Bergonié, 33000 Bordeaux (France); Buy, X. [Department of Radiology, Institut Bergonié, 229 cours de l’Argonne, 33076 Bordeaux Cedex (France); Coindre, J-M. [Department of Pathology, Institut Bergonié, 229 cours de l’Argonne, 33076 Bordeaux Cedex (France); Kind, M. [Department of Radiology, Institut Bergonié, 229 cours de l’Argonne, 33076 Bordeaux Cedex (France)

    2016-10-15

    Objectives: To retrospectively evaluate the diagnostic performance of morphological signs observed on conventional magnetic resonance (MR) imaging to differentiate benign from malignant peripheral solid tumors of soft tissue with myxoid stroma. Methods: MR images from 95 consecutive histopathologically proven tumors (26 benign and 69 malignant) of soft tissues with myxoid components were evaluated in our tertiary referral center. Two radiologists, blind to pathology results, independently reviewed conventional MR sequences including at least a) one T2-weighted sequence with or without fat suppression; b) one T1-weighted sequence without fat suppression; and c) one T1-weighted sequence with gadolinium-complex contrast enhancement and fat suppression. Multiple criteria were defined to analyze morphology, margins, architecture and tumor periphery and evaluated for each lesion. Intra- and inter-observer reproducibility and Odds ratios were calculated for each criterion. Results: The most relevant and reproducible criteria to significantly predict malignancy were: (1) ill-defined tumor margins, (2) a hemorrhagic component, (3) intra-tumoral fat, (4) fibrosis and (5) the “tail sign”. A lesion is classified as malignant if any of these 5 criteria is present, and benign if none of them are observed. Therefore, this combination provides a sensitivity of 92.9% and a specificity of 93.3%. Conclusion: Conventional MR imaging provides reproducible criteria that can be combined to differentiate between benign and malignant solid tumors of soft tissue with myxoid stroma.

  19. A new test phantom with different breast tissue compositions for image quality assessment in conventional and digital mammography

    International Nuclear Information System (INIS)

    Pachoud, Marc; Lepori, D; Valley, Jean-Francois; Verdun, Francis R

    2004-01-01

    Our objective is to describe a new test phantom that permits the objective assessment of image quality in conventional and digital mammography for different types of breast tissue. A test phantom, designed to represent a compressed breast, was made from tissue equivalent materials. Three separate regions, with different breast tissue compositions, are used to evaluate low and high contrast resolution, spatial resolution and image noise. The phantom was imaged over a range of kV using a Contour 2000 (Bennett) mammography unit with a Kodak MinR 2190-MinR L screen-film combination and a Senograph 2000D (General Electric) digital mammography unit. Objective image quality assessments for different breast tissue compositions were performed using the phantom for conventional and digital mammography. For a similar mean glandular dose (MGD), the digital system gives a significantly higher contrast-to-noise ratio (CNR) than the screen-film system for 100% glandular tissue. In conclusion, in mammography, a range of exposure conditions is used for imaging because of the different breast tissue compositions encountered clinically. Ideally, the patient dose-image quality relationship should be optimized over the range of exposure conditions. The test phantom presented in this work permits image quality parameters to be evaluated objectively for three different types of breast tissue. Thus, it is a useful tool for optimizing the patient dose-image quality relationship

  20. Comparative assessment of surgeons' task performance and surgical ergonomics associated with conventional and modified flank positions: a simulation study.

    Science.gov (United States)

    Fan, Yu; Kong, Gaiqing; Meng, Yisen; Tan, Shutao; Wei, Kunlin; Zhang, Qian; Jin, Jie

    2014-11-01

    Flank position is extensively used in retroperitoneoscopic urological practice. Most surgeons follow the patients' position in open approaches. However, surgical ergonomics of the conventional position in the retroperitoneoscopic surgery is poor. We introduce a modified position and evaluated task performance and surgical ergonomics of both positions with simulated surgical tasks. Twenty-one novice surgeons were recruited to perform four tasks: bead transfer, ring transfer, continuous suturing, and cutting a circle. The conventional position was simulated by setting an endo-surgical simulator parallel to the long axis of a surgical desk. The modified position was simulated by rotating the simulator 30° with respect to the long axis of the desk. The outcome measurements include task performance measures, kinematic measures for body alignment, surface electromyography, relative loading between feet, and subjective ratings of fatigue. We observed significant improvements in both task performance and surgical ergonomics parameters under the modified position. For all four tasks, subjects finished tasks faster with higher accuracy (p ergonomics part: (1) The angle between the upper body and the head was decreased by 7.4 ± 1.7°; (2) The EMG amplitude collected from shoulders and left lumber was significantly lower (p ergonomics. With a simulated surgery, we demonstrated that our modified position could significantly improve task performance and surgical ergonomics. Further studies are still warranted to validate these benefits for both patients and surgeons.

  1. Noninvasive Positive Pressure Ventilation or Conventional Mechanical Ventilation for Neonatal Continuous Positive Airway Pressure Failure

    Directory of Open Access Journals (Sweden)

    Zohreh Badiee

    2014-01-01

    Full Text Available Background: The aim of this study was to assess the success rate of nasal intermittent positive pressure ventilation (NIPPV for treatment of continuous positive airway pressure (CPAP failure and prevention of conventional ventilation (CV in preterm neonates. Methods: Since November 2012 to April 2013, a total number of 55 consecutive newborns with gestational ages of 26-35 weeks who had CPAP failure were randomly assigned to one of the two groups. The NIPPV group received NIPPV with the initial peak inspiratory pressure (PIP of 16-20 cmH 2 O and frequency of 40-60 breaths/min. The CV group received PIP of 12-20 cmH 2 O and frequency of 40-60 breaths/min. Results: About 74% of newborns who received NIPPV for management of CPAP failure responded to NIPPV and did not need intubation and mechanical ventilation. Newborns with lower postnatal age at entry to the study and lower 5 min Apgar score more likely had NIPPV failure. In addition, treatment failure was higher in newborns who needed more frequent doses of surfactant. Duration of oxygen therapy was 9.28 days in CV group and 7.77 days in NIPPV group (P = 0.050. Length of hospital stay in CV group and NIPPV groups were 48.7 and 41.7 days, respectively (P = 0.097. Conclusions: NIPPV could decrease the need for intubation and mechanical ventilation in preterm infants with CPAP failure.

  2. Positive media portrayals of obese persons: impact on attitudes and image preferences.

    Science.gov (United States)

    Pearl, Rebecca L; Puhl, Rebecca M; Brownell, Kelly D

    2012-11-01

    The purpose of this research was to assess the impact of nonstereotypical, positive media portrayals of obese persons on biased attitudes, as well as propose a change in media practices that could reduce public weight bias and consequent negative health outcomes for those who experience weight stigma. Two online experiments were conducted in which participants viewed either a stigmatizing or a positive photograph of an obese model. In Experiment 1 (N = 146), participants viewed a photograph of either a Caucasian or African American obese woman; in Experiment 2 (N = 145), participants viewed either a Caucasian male or female obese model. Multiple linear regression models were used to analyze outcomes for social distance attitudes toward the obese models depicted in the images, in addition to other negative attitudes and image preferences. Participants who viewed the stigmatizing images endorsed stronger social distance attitudes and more negative attitudes toward obese persons than participants who viewed the positive images, and there was a stronger preference for the positive images than the stigmatizing images. These results were consistent regardless of the race or gender of the obese model pictured. The findings indicate that more positive media portrayals of obese individuals may help reduce weight stigma and its associated negative health outcomes.

  3. Facile Fabrication of Animal-Specific Positioning Molds For Multi-modality Molecular Imaging

    International Nuclear Information System (INIS)

    Park, Jeong Chan; Oh, Ji Eun; Woo, Seung Tae

    2008-01-01

    Recently multi-modal imaging system has become widely adopted in molecular imaging. We tried to fabricate animal-specific positioning molds for PET/MR fusion imaging using easily available molding clay and rapid foam. The animal-specific positioning molds provide immobilization and reproducible positioning of small animal. Herein, we have compared fiber-based molding clay with rapid foam in fabricating the molds of experimental animal. The round bottomed-acrylic frame, which fitted into microPET gantry, was prepared at first. The experimental mice was anesthetized and placed on the mold for positioning. Rapid foam and fiber-based clay were used to fabricate the mold. In case of both rapid foam and the clay, the experimental animal needs to be pushed down smoothly into the mold for positioning. However, after the mouse was removed, the fabricated clay needed to be dried completely at 60 .deg. C in oven overnight for hardening. Four sealed pipe tips containing [ 18 F]FDG solution were used as fiduciary markers. After injection of [ 18 F]FDG via tail vein, microPET scanning was performed. Successively, MRI scanning was followed in the same animal. Animal-specific positioning molds were fabricated using rapid foam and fiber-based molding clay for multimodality imaging. Functional and anatomical images were obtained with microPET and MRI, respectively. The fused PET/MR images were obtained using freely available AMIDE program. Animal-specific molds were successfully prepared using easily available rapid foam, molding clay and disposable pipet tips. Thanks to animal-specific molds, fusion images of PET and MR were co-registered with negligible misalignment

  4. Clinical value of imaging using antibody to alpha fetoprotein in germ cell tumours

    International Nuclear Information System (INIS)

    Hitchins, R.N.; Begent, R.H.J.; Green, A.J.; Searle, F.; Bagshawe, K.D.; Charing Cross Group of Hospitals, London; Van Heyningen, V.

    1989-01-01

    Germ cell tumours (GCT) producing alpha fetoprotein (aFP) can be imaged by external scintigraphy after intraveneous administration of radiolabelled antibody directed against aFP. Antibody imaging (AI) by this method was used in an attempt to guide surgical resection of deposits of drug-resistant or recurrent GCT. 30 patients with GCT and raised aFP in whom site of tumour was not known were investigated by AI and conventional imaging methods. All but one were heavily pretreated. Where tumour appeared localised, resection was attempted. Tumour was found in all sites positive by both AI and conventional imaging. AI produced false-positive results in one of 30 patients and false-negative results in 9 patients. Computerised tomography was false-positive in one case and false-negative in three. In these patients, AI gave true-negative and true-positive results, respectively. Of 11 patients with positive AI in whom resection was attempted, 6 achieved sustained complete response with up to 5 years follow-up. We conclude AI and conventional imaging methods to be complementary in selection for surgery of patients with drug-resistant or recurrent GCT. (orig.) [de

  5. Conventional MRI and magnetisation transfer imaging of tumour-like multiple sclerosis in a child

    International Nuclear Information System (INIS)

    Metafratzi, Z.; Argyropoulou, M.I.; Efremidis, S.C.; Tzoufi, M.; Papadopoulou, Z.

    2002-01-01

    Tumefactive multiple sclerosis is a rare entity in children. Differential diagnosis includes other mass lesions such as neoplasm and abscess. A case of tumefactive multiple sclerosis in a child is presented. The open-ring pattern of enhancement on conventional MRI and magnetisation transfer imaging was important for the initial diagnosis and the evaluation of the course of the disease. (orig.)

  6. CT simulation technique for craniospinal irradiation in supine position

    International Nuclear Information System (INIS)

    Lee, Suk; Kim, Yong Bae; Chu, Sung Sil; Suh, Chang Ok; Kwon, Soo Il

    2002-01-01

    In order to perform craniospinal irradiation (CSI) in the supine position on patients who are unable to lie in the prone position, a new simulation technique using a CT simulator was developed and its availability was evaluated. A CT simulator and a 3-D conformal treatment planning system were used to develop CSI in the supine position. The head and neck were immobilized with a thermoplastic mask in the supine position and the entire body was immobilized with a Vac-Loc. A volumetric image was then obtained using the CT simulator. In order to improve the reproducibility of the patients' setup, datum lines and points were marked on the head and the body. Virtual fluoroscopy was performed with the removal of visual obstacles such as the treatment table or the immobilization devices. After the virtual simulation, the treatment isocenters of each field were marked on the body and the immobilization devices at the conventional simulation room. Each treatment field was confirmed by comparing the fluoroscopy images with the digitally reconstructed radiography (DRR)/digitally composite radiography (DCR) images from the virtual simulation. The port verification films from the first treatment were also compared with the DRR/DCR images for a geometrical verification. CSI in the supine position was successfully performed in 9 patients. It required less than 20 minutes to construct the immobilization device and to obtain the whole body volumetric images. This made it possible to not only reduce the patients' inconvenience, but also to eliminate the position change variables during the long conventional simulation process. In addition, by obtaining the CT volumetric image, critical organs, such as the eyeballs and spinal cord, were better defined, and the accuracy of the port designs and shielding was improved. The difference between the DRRs and the portal films were less than 3 mm in the vertebral contour. CSI in the supine position is feasible in patients who cannot lie on

  7. CT simulation technique for craniospinal irradiation in supine position

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Suk; Kim, Yong Bae; Chu, Sung Sil; Suh, Chang Ok [Yonsei Cancer Center, College of Medicine, Yonsei University, Seoul (Korea, Republic of); Kwon, Soo Il [Kyonggi University, Seoul (Korea, Republic of)

    2002-06-15

    In order to perform craniospinal irradiation (CSI) in the supine position on patients who are unable to lie in the prone position, a new simulation technique using a CT simulator was developed and its availability was evaluated. A CT simulator and a 3-D conformal treatment planning system were used to develop CSI in the supine position. The head and neck were immobilized with a thermoplastic mask in the supine position and the entire body was immobilized with a Vac-Loc. A volumetric image was then obtained using the CT simulator. In order to improve the reproducibility of the patients' setup, datum lines and points were marked on the head and the body. Virtual fluoroscopy was performed with the removal of visual obstacles such as the treatment table or the immobilization devices. After the virtual simulation, the treatment isocenters of each field were marked on the body and the immobilization devices at the conventional simulation room. Each treatment field was confirmed by comparing the fluoroscopy images with the digitally reconstructed radiography (DRR)/digitally composite radiography (DCR) images from the virtual simulation. The port verification films from the first treatment were also compared with the DRR/DCR images for a geometrical verification. CSI in the supine position was successfully performed in 9 patients. It required less than 20 minutes to construct the immobilization device and to obtain the whole body volumetric images. This made it possible to not only reduce the patients' inconvenience, but also to eliminate the position change variables during the long conventional simulation process. In addition, by obtaining the CT volumetric image, critical organs, such as the eyeballs and spinal cord, were better defined, and the accuracy of the port designs and shielding was improved. The difference between the DRRs and the portal films were less than 3 mm in the vertebral contour. CSI in the supine position is feasible in patients who cannot

  8. Addition of tomosynthesis to conventional digital mammography: effect on image interpretation time of screening examinations.

    Science.gov (United States)

    Dang, Pragya A; Freer, Phoebe E; Humphrey, Kathryn L; Halpern, Elkan F; Rafferty, Elizabeth A

    2014-01-01

    To determine the effect of implementing a screening tomosynthesis program on real-world clinical performance by quantifying differences between interpretation times for conventional screening mammography and combined tomosynthesis and mammography for multiple participating radiologists with a wide range of experience in a large academic center. In this HIPAA-compliant, institutional review board-approved study, 10 radiologists prospectively read images from screening digital mammography or screening combined tomosynthesis and mammography examinations for 1-hour-long uninterrupted sessions. Images from 3665 examinations (1502 combined and 2163 digital mammography) from July 2012 to January 2013 were interpreted in at least five sessions per radiologist per modality. The number of cases reported during each session was recorded for each reader. The experience level for each radiologist was also correlated to the average number of cases reported per hour. Analysis of variance was used to assess the number of studies interpreted per hour. A linear regression model was used to evaluate correlation between breast imaging experience and time taken to interpret images from both modalities. The mean number of studies interpreted in hour was 23.8 ± 0.55 (standard deviation) (range, 14.4-40.4) for combined tomosynthesis and mammography and 34.0 ± 0.55 (range, 20.4-54.3) for digital mammography alone. A mean of 10.2 fewer studies were interpreted per hour during combined tomosynthesis and mammography compared with digital mammography sessions (P tomosynthesis and mammography and 1.9 minutes ± 0.6 (range, 1.1-3.0) for digital mammography; interpretation time with combined tomosynthesis and mammography was 0.9 minute longer (47% longer) compared with digital mammography alone (P tomosynthesis and mammography examinations decreased (R(2) = 0.52, P = .03). Addition of tomosynthesis to mammography results in increased time to interpret images from screening examinations compared

  9. 18F-FDG PET/CT in paediatric lymphoma: comparison with conventional imaging

    International Nuclear Information System (INIS)

    London, Kevin; Cross, Siobhan; Dalla-Pozza, Luciano; Onikul, Ella; Howman-Giles, Robert

    2011-01-01

    In children with Hodgkin's disease and non-Hodgkin's lymphoma, the ability of 18 F-fluoro-2-deoxy-D-glucose PET/CT and conventional imaging (CI) to detect malignant lesions and predict poor lesion response to therapy was assessed and compared. A retrospective review of findings reported on PET/CT and CI was performed using a lesion-based analysis of 16 lymph node and 8 extra-nodal regions. Lesions were defined by histopathological findings or follow-up > 6 months. The study included 209 PET/CT scans with a valid CI comparator. A total of 5,014 regions (3,342 lymph node, 1,672 extra-nodal) were analysed. PET/CT performed significantly better than CI in the detection of malignant lesions with sensitivity and specificity of 95.9 and 99.7% compared to 70.1 and 99.0%, respectively. For predicting poor lesion response to therapy, PET/CT had fewer false-positive lesions than CI. The specificity for predicting poor lesion response to treatment for PET/CT was 99.2% compared to 96.9% for CI. PET/CT was the correct modality in 86% of lesions with discordant findings. PET/CT is more accurate than CI in detecting malignant lesions in childhood lymphoma and in predicting poor lesion response to treatment. In lesions with discordant findings, PET/CT results are more likely to be correct. (orig.)

  10. Positioning of Nuclear Fuel Assemblies by Means of Image Analysis on Tomographic Data

    International Nuclear Information System (INIS)

    Troeng, Mats

    2005-06-01

    A tomographic measurement technique for nuclear fuel assemblies has been developed at the Department of Radiation Sciences at Uppsala University. The technique requires highly accurate information about the position of the measured nuclear fuel assembly relative to the measurement equipment. In experimental campaigns performed earlier, separate positioning measurements have therefore been performed in connection to the tomographic measurements. In this work, another positioning approach has been investigated, which requires only the collection of tomographic data. Here, a simplified tomographic reconstruction is performed, whereby an image is obtained. By performing image analysis on this image, the lateral and angular position of the fuel assembly can be determined. The position information can then be used to perform a more accurate tomographic reconstruction involving detailed physical modeling. Two image analysis techniques have been developed in this work. The stability of the two techniques with respect to some central parameters has been studied. The agreement between these image analysis techniques and the previously used positioning technique was found to meet the desired requirements. Furthermore, it has been shown that the image analysis techniques offer more detailed information than the previous technique. In addition, its off-line analysis properties reduce the need for valuable measurement time. When utilizing the positions obtained from the image analysis techniques in tomographic reconstructions of the rod-by-rod power distribution, the repeatability of the reconstructed values was improved. Furthermore, the reconstructions resulted in better agreement to theoretical data

  11. Conventional radiography and computed tomography of cardiac assist devices

    Energy Technology Data Exchange (ETDEWEB)

    Scheffel, Hans; Stolzmann, Paul; Desbiolles, Lotus; Leschka, Sebastian; Frauenfelder, Thomas; Schertler, Thomas; Marincek, Borut; Alkadhi, Hatem [University Hospital Zurich, Institute of Diagnostic Radiology, Zurich (Switzerland); Wilhelm, Markus J.; Lachat, Mario [University Hospital Zurich, Clinic for Cardiovascular Surgery, Zurich (Switzerland)

    2009-09-15

    Patients intended for circulatory support by cardiac assist devices (CAD) usually suffer from end-stage acute or chronic heart failure. Since the introduction of CAD in 1963 by DeBakey and coworkers, the systems have gone through a substantial evolution and have been increasingly used in the intervening decades. The spectrum of CAD includes a variety of systems serving to assist the systolic function of the left ventricle, the right ventricle, or both. Conventional radiography and multislice spiral computed tomography (CT) are the most commonly used radiological techniques for imaging patients with a CAD. CT is very useful for evaluating CAD systems by using both two- and three-dimensional reconstructions of the volumetric data sets. The two techniques together allow for the comprehensive assessment of patients with devices by imaging the in- and outflow cannulae, the anastomoses, the position of the pump, as well as associated complications. A close collaboration with cardiac surgeons with expertise in the field of circulatory support is deemed necessary for adequate image interpretation. This article describes the technical diversity of the currently available CAD systems. The imaging characteristics on conventional radiography and multislice spiral CT as well as the typical complications of their use are demonstrated. (orig.)

  12. Preliminary results for positron emission mammography: real-time functional breast imaging in a conventional mammography gantry

    International Nuclear Information System (INIS)

    Weinberg, I.; Majewski, S.; Weisenberger, A.; Markowitz, A.; Aloj, L.; Majewski, L,; Danforth, D.; Mulshine, J.; Cowan, K.; Zujewski, J.; Chow, C.; Jones, E.; Chang, V.; Berg, W.; Frank, J.

    1996-01-01

    In order to optimally integrate radiotracer breast imaging within the breast clinic, anatomy and pathology should be easily correlated with functional nuclear medicine breast images. As a first step in the development of a hybrid functional/anatomic breast imaging platform with biopsy capability, a conventional X-ray mammography gantry was modified to image the compressed brest with positron emitters. Phantom studies with the positron emission mammography (PEM) device showed that a 1-cc hot spot could be detected within 5 min. A preliminary clinical trial demonstrated in vivo visualization of primary breast cancer within 4 min. For sites where positron-emitting radionuclides are available, PEM promises to achieve low-cost directed functional examination of breast abnormalities, with potential for achieving X-ray correlation and image-guided biopsy. (orig.)

  13. Spontaneous vaginal delivery in the birth-chair versus in the conventional dorsal position: a matched controlled comparison.

    Science.gov (United States)

    Scholz, H S; Benedicic, C; Arikan, M G; Haas, J; Petru, E

    2001-09-17

    The aim of the study was to assess the effect of a birth-chair on obstetric outcome. We reviewed the hospital records of 220 consecutive pregnant women who gave birth on a birth-chair at our institution. The control group consisted of 440 pregnant women who preceded and followed the index cases and who had spontaneous vaginal deliveries in the conventional dorsal supine position. The controls were matched for parity and for the attending mid-wife. Patients who delivered in the birth-chair had significantly lower rates of episiotomy and manual separation of the placenta. The umbilical blood cord pH was significantly higher in neonates of the birth-chair group. The duration of labour, rate of perineal and vaginal injury, Apgar scores and rate of admission to a neonatal intermediate care unit were not influenced by the mode of delivery. Our data support previous studies that a birth-chair delivery may be a safe alternative to conventional delivery in the supine position.

  14. Imaging systems in nuclear medicine and image evaluation

    International Nuclear Information System (INIS)

    Beck, R.; Charleston, D.; Metz, C.; Tsui, B.

    1981-01-01

    A general computer code to simulate the imaging properties of existing and hypothetical imaging systems viewing realistic source distributions within non-uniform media. Such a code allows comparative evaluations of existing and hypothetical systems, and optimization of critical parameters of system design by maximizing the signal-to-noise ratio. To be most useful, such a code allows simulation of conventional scintillation scanners and cameras as well as single-photon and position tomographic systems

  15. Prediction of Helicobacter pylori status by conventional endoscopy, narrow-band imaging magnifying endoscopy in stomach after endoscopic resection of gastric cancer.

    Science.gov (United States)

    Yagi, Kazuyoshi; Saka, Akiko; Nozawa, Yujiro; Nakamura, Atsuo

    2014-04-01

    To reduce the incidence of metachronous gastric carcinoma after endoscopic resection of early gastric cancer, Helicobacter pylori eradication therapy has been endorsed. It is not unusual for such patients to be H. pylori negative after eradication or for other reasons. If it were possible to predict H. pylori status using endoscopy alone, it would be very useful in clinical practice. To clarify the accuracy of endoscopic judgment of H. pylori status, we evaluated it in the stomach after endoscopic submucosal dissection (ESD) of gastric cancer. Fifty-six patients treated by ESD were enrolled. The diagnostic criteria for H. pylori status by conventional endoscopy and narrow-band imaging (NBI)-magnifying endoscopy were decided, and H. pylori status was judged by two endoscopists. Based on the H. pylori stool antigen test as a diagnostic gold standard, conventional endoscopy and NBI-magnifying endoscopy were compared for their sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). Interobserver agreement was assessed in terms of κ value. Interobserver agreement was moderate (0.56) for conventional endoscopy and substantial (0.77) for NBI-magnifying endoscopy. The sensitivity, specificity, PPV, and NPV were 0.79, 0.52, 0.70, and 0.63 for conventional endoscopy and 0.91, 0.83, 0.88, and 0.86 for NBI-magnifying endoscopy, respectively. Prediction of H. pylori status using NBI-magnifying endoscopy is practical, and interobserver agreement is substantial. © 2013 John Wiley & Sons Ltd.

  16. Intraoperative three-dimensional fluoroscopy after transpedicular positioning of Kirschner-wire versus conventional intraoperative biplanar fluoroscopic control: A retrospective study of 345 patients and 1880 pedicle screws

    Directory of Open Access Journals (Sweden)

    Ghassan Kerry

    2014-01-01

    Full Text Available Study Design: Retrospective study. Objective: The aim was to find out whether intraoperative three-dimensional imaging after transpedicular positioning of Kirschner wire (K-wire in lumbar and thoracic posterior instrumentation procedures is of benefit to the patients and if this technique is accurately enough to make a postoperative screw position control through computer tomography (CT dispensable. Patients and Methods: Lumbar and thoracic posterior instrumentation procedures conducted at our department between 2002 and 2012 were retrospectively reviewed. The patients were divided into two groups: group A, including patients who underwent intraoperative three-dimensional scan after transpedicular positioning of the K-wire and group B, including patients who underwent only intraoperative biplanar fluoroscopy. An early postoperative CT of the instrumented section was done in all cases to assess the screw position. The rate of immediate intraoperative correction of the K-wires in cases of mal-positioning, as well as the rate of postoperative screw revisions, was measured. Results: In general, 345 patients (1880 screws were reviewed and divided into two groups; group A with 225 patients (1218 screws and group B with 120 patients (662 screws. One patient (0.44% (one screw [0.082%] of group A underwent postoperative screw correction while screw revisions were necessary in 14 patients (11.7% (28 screws [4.2%] of group B. Twenty-three patients (10.2% (28 K-wires [2.3%] of group A underwent intraoperative correction due to primary intraoperative detected K-wire mal-position. None of the corrected K-wires resulted in a corresponding neurological deficit. Conclusion: Three-dimensional imaging after transpedicular K-wire positioning leads to solid intraoperative identification of misplaced K-wires prior to screw placement and reduces screw revision rates compared with conventional fluoroscopic control. When no clinical deterioration emerges, a

  17. Application of position-sensitive detectors to positron imaging

    International Nuclear Information System (INIS)

    Yamashita, Takaji; Uchida, Hiroshi; Watanabe, Mitsuo; Omura, Tomohide

    1994-01-01

    Positron imaging including positron emission tomography (PET) is expected to be a promising tool for basic and clinical research, because it makes possible the study of regional chemistry within multiple organs of the body in living human beings and experimental animals. New schemes of high resolution block detectors have been developed to improve the performance of positron imaging systems, which employ small segments of bismuth germanate (BGO) arrays and position-sensitive photomultiplier tubes (PS-PMT). The coincidence detector resolution of less than 2.0 mm in full width at half maximum was achieved with the detectors, which is very close to the theoretical resolution limit in positron imaging. (author)

  18. PAPNET-assisted primary screening of conventional cervical smears.

    Science.gov (United States)

    Cenci, M; Nagar, C; Vecchione, A

    2000-01-01

    The PAPNET System is the only device with a neural-network-based-artificial intelligence to detect and show the images of abnormal cells on the monitor to be evaluated in an interactive way. We effectively used the PAPNET in rescreening of conventional cervical smears and we detected its advantages and its disadvantages. In this paper, we report our results from PAPNET-assisted primary screening performed on 20,154 conventional smears. The smears were classified as Negative or as Review. The Negative cases were rapidly rescreened mainly near the coverslip edges, which are the slide areas not analyzed by automated devices because of focusing problems. The Review cases were fully reanalyzed by the optic microscope. In summary, 140 positive smears were detected: 57 cases showed changes due to HPV, 63 LSIL, 15 HSIL, and 5 carcinomas. Therefore, the PAPNET System was confirmed as useful in primary screening of conventional cervical samples as well as rescreening.

  19. Image annotation based on positive-negative instances learning

    Science.gov (United States)

    Zhang, Kai; Hu, Jiwei; Liu, Quan; Lou, Ping

    2017-07-01

    Automatic image annotation is now a tough task in computer vision, the main sense of this tech is to deal with managing the massive image on the Internet and assisting intelligent retrieval. This paper designs a new image annotation model based on visual bag of words, using the low level features like color and texture information as well as mid-level feature as SIFT, and mixture the pic2pic, label2pic and label2label correlation to measure the correlation degree of labels and images. We aim to prune the specific features for each single label and formalize the annotation task as a learning process base on Positive-Negative Instances Learning. Experiments are performed using the Corel5K Dataset, and provide a quite promising result when comparing with other existing methods.

  20. Improvement of Gaofen-3 Absolute Positioning Accuracy Based on Cross-Calibration

    Directory of Open Access Journals (Sweden)

    Mingjun Deng

    2017-12-01

    Full Text Available The Chinese Gaofen-3 (GF-3 mission was launched in August 2016, equipped with a full polarimetric synthetic aperture radar (SAR sensor in the C-band, with a resolution of up to 1 m. The absolute positioning accuracy of GF-3 is of great importance, and in-orbit geometric calibration is a key technology for improving absolute positioning accuracy. Conventional geometric calibration is used to accurately calibrate the geometric calibration parameters of the image (internal delay and azimuth shifts using high-precision ground control data, which are highly dependent on the control data of the calibration field, but it remains costly and labor-intensive to monitor changes in GF-3’s geometric calibration parameters. Based on the positioning consistency constraint of the conjugate points, this study presents a geometric cross-calibration method for the rapid and accurate calibration of GF-3. The proposed method can accurately calibrate geometric calibration parameters without using corner reflectors and high-precision digital elevation models, thus improving absolute positioning accuracy of the GF-3 image. GF-3 images from multiple regions were collected to verify the absolute positioning accuracy after cross-calibration. The results show that this method can achieve a calibration accuracy as high as that achieved by the conventional field calibration method.

  1. Transformation of Image Positions, Rotations, and Sizes into Shift Parameters

    DEFF Research Database (Denmark)

    Skov Jensen, A.; Lindvold, L.; Rasmussen, E.

    1987-01-01

    An optical image processing system is described that converts orientation and size to shift properties and simultaneously preserves the positional information as a shift. The system is described analytically and experimentally. The transformed image can be processed further with a classical...... correlator working with a rotational and size-invariant. multiplexed match filter. An optical robot vision system designed on this concept would be able to look at several objects simultaneously and determine their shape, size, orientation, and position with two measurements on the input scene at different...

  2. Cerebral perfusion imaging in HIV positive patients

    International Nuclear Information System (INIS)

    Kundley, Kshama; Chowdhury, D.; Lele, V.R.; Lele, R.D.

    1998-01-01

    Full text: Twelve human immunodeficiency virus (HIV) positive patients were studied by SPECT cerebral perfusion imaging 1 hour post injection of 15 mCi of 99m Tc-ECD under ideal conditions with a triple head gamma camera (Prism 3000 X P LEUHR), fanbeam collimators followed by Folstein Mini Mental Status Examination (FMMSE) and AIDS dementia complex (ADC) staging on the same day. All 12 patients were male, in the age range of 23-45 y (mean 31 y). The infected status was diagnosed by ELISA (10 patients) or Western blot (5 patients). The interval between diagnosis and imaging ranged from 1 month - 35 months (mean 15.3 months). Two patients were alcoholic and 2 were smokers. None of them had CNS disorder clinically. ADC staging and FMMSE could be performed in 4 patients. Two patients were normal (stage 0) and 2 were subclinical (stage 0.5) on ADC staging. FMMSE revealed normal or near normal status (mean score 35; maximum score 36). Cerebral perfusion images were interpreted simultaneously by 3 observers blind towards history and examination using semi-quantitative and quantitative methods by consensus. It revealed multiple areas of hypoperfusion, viz. temporal (11 patients (91 %), parietal 10 patients (83%), frontal 9 patients (75%, pre and post central gyrus 7 patients (58%), occipital 6 patients (50%) cingulate gyrus and cerebellum 5 patients (41%) and thalamic in 2 patients (16%). Hyper perfusion in caudate nuclei was noted in 10 patients (83%). The study reveals presence of multiple perfusion abnormalities on cerebral perfusion imaging in HIV positive patients who have normal/near normal mental status suggesting precedence of perfusion abnormality over clinically apparent mental deficit

  3. Comparison of oxygen saturation levels in patients receiving Technegas by the conventional unassisted method vs. the positive ventilation delivery system (PVDS)

    International Nuclear Information System (INIS)

    Dobson, M.P.; Leiper, C.A.; Lee, K.; Dixson, H.

    2000-01-01

    Full text: The purpose of this study is to compare oxygen saturation levels (SaO 2 ) in 289 patients undergoing conventional lung ventilation scintigraphy (control group) and 27 patients undergoing Positive Ventilation Delivery System (PVDS). The 27 patients where selected as their conventional method of inhalation proved to be inadequate or non-diagnostic. The patients underwent a second ventilation using PVDS, which improved the diagnostic quality of the ventilation image and assisted in clinical management decisions. Some patients in both the PVDS and the control group experienced a transient lowering in their SaO 2 . The mean initial SaO 2 in the control group did not fall below 94.9% and in the PVDS group measured 90.6%. 93% (25/27) of patients in the PVDS group were assessed as non CO 2 retaining, and received oxygen at 10L/min during Technegas inhalation. The mean trough saturation in the PVDS group was 91.7% which was significantly higher than that of the control group (86.9%). No patient in either group experienced any significant complication attributed to the transient tall in SaO 2 during technegas administration. We conclude that oxygen supplied as part of the PVDS system ameliorates the transient reduction in SaO 2 seen during standard Technegas administration. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  4. The Institution Image and Trust and Their Effect on the Positive Word of Mouth

    Directory of Open Access Journals (Sweden)

    Soni Harsono

    2014-04-01

    Full Text Available In marketing, it is important to see how competitive a university is. Among public universities (PTN and private universities (PTS, it shows a very competitive situation recently. To overcome this problem, it requires shaping up the institution image and trust for increasing the positive word of mouth among students. This study aims to determine the effect of the institution image, trust both partially and simultaneously on the positive word of mouth by the students of private universities in Surabaya with their accreditation levels of A, B and C. The sample consists of students from six colleges with accreditation ratings A, B, and C totaling 125 students. Accidental sampling technique was done using a sampling technique of multiple regression analysis with SPSS version 17. It shows, for the college with accreditation category C, the image of the institution both partially and simulta-neously has significant positive effect on the positive word of mouth. For the college accreditation category B, the image of the institution and trust simultaneously has significant positive effect on the positive word of mouth and, finally, trust in accreditation category A has significant positive effect on the positive word of mouth and the institution image and trust simultaneously have significant positive effect on the positive word of mouth.

  5. Enough positive rate of paraspinal mapping and diffusion tensor imaging with levels which should be decompressed in lumbar spinal stenosis.

    Science.gov (United States)

    Chen, Hua-Biao; Zhong, Zhi-Wei; Li, Chun-Sheng; Bai, Bo

    2016-07-01

    In lumbar spinal stenosis, correlating symptoms and physical examination findings with decompression levels based on common imaging is not reliable. Paraspinal mapping (PM) and diffusion tensor imaging (DTI) may be possible to prevent the false positive occurrences with MRI and show clear benefits to reduce the decompression levels of lumbar spinal stenosis than conventional magnetic resonance imaging (MRI) + neurogenic examination (NE). However, they must have enough positive rate with levels which should be decompressed at first. The study aimed to confirm that the positive of DTI and PM is enough in levels which should be decompressed in lumbar spinal stenosis. The study analyzed the positive of DTI and PM as well as compared the preoperation scores to the postoperation scores, which were assessed preoperatively and at 2 weeks, 3 months 6 months, and 12 months postoperatively. 96 patients underwent the single level decompression surgery. The positive rate among PM, DTI, and (PM or DTI) was 76%, 98%, 100%, respectively. All post-operative Oswestry Disability Index (ODI), visual analog scale for back pain (VAS-BP) and visual analog scale for leg pain (VAS-LP) scores at 2 weeks postoperatively were measured improvement than the preoperative ODI, VAS-BP and VAS-LP scores with statistically significance (p-value = 0.000, p-value = 0.000, p-value = 0.000, respectively). In degenetive lumbar spinal stenosis, the positive rate of (DTI or PM) is enough in levels which should be decompressed, thence using the PM and DTI to determine decompression levels will not miss the level which should be operated. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  6. Methods for calculating the electrode position Jacobian for impedance imaging.

    Science.gov (United States)

    Boyle, A; Crabb, M G; Jehl, M; Lionheart, W R B; Adler, A

    2017-03-01

    Electrical impedance tomography (EIT) or electrical resistivity tomography (ERT) current and measure voltages at the boundary of a domain through electrodes. The movement or incorrect placement of electrodes may lead to modelling errors that result in significant reconstructed image artifacts. These errors may be accounted for by allowing for electrode position estimates in the model. Movement may be reconstructed through a first-order approximation, the electrode position Jacobian. A reconstruction that incorporates electrode position estimates and conductivity can significantly reduce image artifacts. Conversely, if electrode position is ignored it can be difficult to distinguish true conductivity changes from reconstruction artifacts which may increase the risk of a flawed interpretation. In this work, we aim to determine the fastest, most accurate approach for estimating the electrode position Jacobian. Four methods of calculating the electrode position Jacobian were evaluated on a homogeneous halfspace. Results show that Fréchet derivative and rank-one update methods are competitive in computational efficiency but achieve different solutions for certain values of contact impedance and mesh density.

  7. Optimising the measurement of bruises in children across conventional and cross polarized images using segmentation analysis techniques in Image J, Photoshop and circle diameter measurements.

    Science.gov (United States)

    Harris, C; Alcock, A; Trefan, L; Nuttall, D; Evans, S T; Maguire, S; Kemp, A M

    2018-02-01

    Bruising is a common abusive injury in children, and it is standard practice to image and measure them, yet there is no current standard for measuring bruise size consistently. We aim to identify the optimal method of measuring photographic images of bruises, including computerised measurement techniques. 24 children aged Photoshop 'ruler' software (Photoshop diameter)). Inter and intra-observer effects were determined by two individuals repeating 11 electronic measurements, and relevant Intraclass Correlation Coefficient's (ICC's) were used to establish reliability. Spearman's rank correlation was used to compare in vivo with computerised measurements; a comparison of measurement techniques across imaging modalities was conducted using Kolmogorov-Smirnov tests. Significance was set at p 0.5 for all techniques, with maximum Feret diameter and maximum Photoshop diameter on conventional images having the strongest correlation with in vivo measurements. There were significant differences between in vivo and computer-aided measurements, but none between different computer-aided measurement techniques. Overall, computer aided measurements appeared larger than in vivo. Inter- and intra-observer agreement was high for all maximum diameter measurements (ICC's > 0.7). Whilst there are minimal differences between measurements of images obtained, the most consistent results were obtained when conventional images, segmented by Image J Software, were measured with a Feret diameter. This is therefore proposed as a standard for future research, and forensic practice, with the proviso that all computer aided measurements appear larger than in vivo. Copyright © 2018 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  8. Performance of Myocardial Perfusion Imaging Using Multi-focus Fan Beam Collimator with Resolution Recovery Reconstruction in a Comparison with Conventional SPECT

    International Nuclear Information System (INIS)

    Matsutomo, Norikazu; Nagaki, Akio; Sasaki, Masayuki

    2014-01-01

    IQ-SPECT is an advanced high-speed SPECT modality for myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQ-SPECT with conventional SPECT in terms of performance, based on standard clinical protocols. In addition, we examined the concordance between conventional and IQ-SPECT in patients with coronary artery disease (CAD). Fifty-three patients, undergoing rest-gated MPI for the evaluation of known or suspected CAD, were enrolled in this study. In each patient, conventional SPECT ( 99m Tc-tetrofosmin, 9.6 min and 201 Tl, 12.9 min) was performed, immediately followed by IQ-SPECT, using a short acquisition time (4.3 min for 99m Tc-tetrofosmin and 6.2 min for 201 Tl). A quantitative analysis was performed on an MPI polar map, using a 20-segment model of the left ventricle. An automated analysis by gated SPECT was carried out to determine the left ventricular volume and function including end-diastolic volume (EDV), end-systolic volume (ESV), and left ventricular ejection fraction (LVEF). The degree of concordance between conventional SPECT and IQ-SPECT images was evaluated according to linear regression and Bland-Altman analyses. The segmental percent uptake exhibited a significant correlation between IQ-SPECT and conventional SPECT (P<0.05). The mean differences in 99m Tc-tetrofosmin studies were 1.1±6.6% (apex), 2.8±5.7% (anterior wall), 2.9±6.2% (septal wall), 4.9±6.7% (lateral wall), and 1.8±5.6% (inferior wall). Meanwhile, regarding the 201 Tl-SPECT studies, these values were 1.6±6.9%, 2.0±6.6%, 2.1±5.9%, 3.3±7.2%, and 2.4±5.8%, respectively. Although the mean LVEF in IQ-SPECT tended to be higher than that observed in conventional SPECT (conventional SPECT=64.8±11.8% and IQ-SPECT=68.3±12.1% for 99m Tc-tetrofosmin; conventional SPECT= 56.0±11.7% and IQ-SPECT=61.5±12.2% for 201 Tl), quantitative parameters were not significantly different between

  9. Basic studies of radiation image diagnosis in veterinary medicine, 1: Comparison of the resolution of computed tomography, scanography and conventional radiography in an equine thoracic phantom

    International Nuclear Information System (INIS)

    Shida, T.; Suganuma, T.; Hashizume, T.

    1984-01-01

    In radiography of the thorax and abdomen of a large animal, the extreme thickness of the body causes a large amount of scattered radiation, which makes it difficult to obtain sharp images. The image resolutions of radiographs obtained by applying conventional radiography, scanography and computed tomography [CT] on an equine thoracic phantom were compared. Tubes of various inside diameters, used to simulate the pulmonary vessels were placed in an equine thoracic phantom and radiographed by CT, scanography and conventional radiography so as to compare the various degrees of resolution of the images of the tubes obtained by these methods. CT and scanography both gave a higher resolution index than conventional radiography, and both provided recognizable images of tubes < 2 mm in diameter, which conventional radiography failed to do. Scanography and CT can be used to obtain high-quality images of the thorax and abdomen of large animals. The image quality was compared using the resolution index (RI). The RI would be a wholly practical and comprehensive index for resolution because it includes 3 factors, contrast, sharpness and magnification, and yet is easy to calculate

  10. Transient Splenial Lesion of Corpus Callosum Associated with Antiepileptic Drug: Conventional and Diffusion-weighted Magnetic Resonance Images

    Energy Technology Data Exchange (ETDEWEB)

    Hakyemez, B.; Erdogan, C.; Yildirim, N.; Gokalp, G.; Parlak, M. [Uludag Univ. Medical School, Bursa (Turkey). Dept. of Radiology

    2005-11-01

    Transient focal lesions of splenium of corpus callosum can be seen as a component of many central nervous system diseases, including antiepileptic drug toxicity. The conventional magnetic resonance (MR) findings of the disease are characteristic and include ovoid lesions with high signal intensity at T2-weighted MRI. Limited information exists about the diffusion-weighted MRI characteristics of these lesions vanishing completely after a period of time. We examined the conventional, FLAIR, and diffusion-weighted MR images of a patient complaining of depressive mood and anxiety disorder after 1 year receiving antiepileptic medication.

  11. Determination of fat and total protein content in milk using conventional digital imaging.

    Science.gov (United States)

    Kucheryavskiy, Sergey; Melenteva, Anastasiia; Bogomolov, Andrey

    2014-04-01

    The applicability of conventional digital imaging to quantitative determination of fat and total protein in cow's milk, based on the phenomenon of light scatter, has been proved. A new algorithm for extracting features from digital images of milk samples has been developed. The algorithm takes into account spatial distribution of light, diffusely transmitted through a sample. The proposed method has been tested on two sample sets prepared from industrial raw milk standards, with variable fat and protein content. Partial Least-Squares (PLS) regression on the features calculated from images of monochromatically illuminated milk samples resulted in models with high prediction performance when analysed the sets separately (best models with cross-validated R(2)=0.974 for protein and R(2)=0.973 for fat content). However when analysed the sets jointly with the obtained results were significantly worse (best models with cross-validated R(2)=0.890 for fat content and R(2)=0.720 for protein content). The results have been compared with previously published Vis/SW-NIR spectroscopic study of similar samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. 5 Ways to Promote a Positive Body Image for Kids

    Science.gov (United States)

    ... physical activity. In contrast, kids with a negative body image feel more self-conscious, anxious and isolated. They are at greater risk for excessive weight gain and for eating disorders. Give your child the gift of positive body image and help prevent these problems — take the following ...

  13. Comparison of fast spin echo, fast multiplanner spoiled gradient recalled and conventional T1 and T2 weighted imaging for experimentally induced hepatic tumors in rats

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Myeong Jin; Lee, Jong Tae; Suh, Jin Suk; Choi, Pil Sik; Lee, Yeon Hee; Yoo, Hyung Sik; Kim, Ki Whang [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1994-10-15

    To compare the ability of tumor detection and the lesion conspicuity between T1- and T2-weighted fast scanning sequence and T1- and T2-weighted conventional spin echo techniques in MR imaging of hepatic tumors. Hepatic tumors were induced on 13 male Sprague-Dawley rats by feeding 3'-methyl-dimethylethyl aminoazobenzene mixed with Miller's III formula for 12 weeks. MR images were obtained with 1.5 T magnet with dual TMJ coil(Sigma, GE Medical systems, Milwaukee, USA). Animals were anesthetized with 150 mg/kg of ketamine hydrochloride. T2 weighted fast spin echo(FSE), conventional spin echo(CSE) T2- and T1WI, fast multiplanner spoiled gradient recalled(FMPSPGR) imaging were obtained. Number of detected tumors and contrast-to-noise ratio of the tumors were compared for each sequence. Overall 110 tumors were developed. 75% of the tumors were detected on FSE. 65% on FMPSPGR, 41% on conventional T2WI, and 41% on T1WI images. For tumors more than 5 mm in diameter, sensitivity was 88% on FMPSPGR, 65% on conventional T2WI, and 81% on T1WI images respectively. CNR of the tumor was 28.94 {+-} 21.6 on FSE, 13.57 {+-} 8.64 on FMPSPGR, 12.62 {+-} 10.65 on CSE T2WI, and 9.47 {+-} 8.05 on CSE T1WI images, which was significantly high on FSE(p<0.05). Fast spin echo T2WI shows highest sensitivity and tumor-to-liver contrast. FMPSPGR imaging is also favorably comparable with conventional T1WI. Therefore, these two pulse sequences can be useful in clinical condition for hepatic MR imaging.

  14. Simple and versatile modifications allowing time gated spectral acquisition, imaging and lifetime profiling on conventional wide-field microscopes

    International Nuclear Information System (INIS)

    Pal, Robert; Beeby, Andrew

    2014-01-01

    An inverted microscope has been adapted to allow time-gated imaging and spectroscopy to be carried out on samples containing responsive lanthanide probes. The adaptation employs readily available components, including a pulsed light source, time-gated camera, spectrometer and photon counting detector, allowing imaging, emission spectroscopy and lifetime measurements. Each component is controlled by a suite of software written in LabVIEW and is powered via conventional USB ports. (technical note)

  15. Implementation of a patient dose monitoring system in conventional digital X-ray imaging: initial experiences

    Energy Technology Data Exchange (ETDEWEB)

    Heilmaier, Christina; Zuber, Niklaus; Weishaupt, Dominik [Stadtspital Triemli Zurich, Department of Radiology and Nuclear Medicine, Zurich (Switzerland)

    2017-03-15

    The purpose was to report on the initial experience after implementation of a patient dose-monitoring system in conventional X-ray imaging. A dose-monitoring system collected dose data relating to different radiographs (one projection) and studies (two or more projections). Images were acquired on digital X-ray systems equipped with flat-panel detectors. During period 1, examinations were performed in a routine fashion in 12,614 patients. After period 1, technical modifications were performed and radiographers underwent training in radiation protection. During period 2, examinations were performed in 14,514 patients, and the radiographers were advised to read dose data after each radiograph/study. Dose data were compared by means of kerma area product (KAP, gray x centimetre squared) and entrance surface air kerma (ESAK, milligray). During period 1, 13,955 radiographs and 8,466 studies were performed, and in period 2 16,090 radiographs and 10,389 studies. In period 2, KAP values for radiographs were an average of 25 % lower and for studies 7 % lower, and ESAK values for radiographs were 24 % lower and for studies 5 % lower. The reduction in KAP was significant in 8/13 radiographs and in 6/14 studies, and the reduction in ESAK was significant in 6/13 radiographs and 5/14 studies. Implementation of a patient dose-monitoring system in conventional X-ray imaging allows easy data collection, supports dose reduction efforts, and may increase radiographers' dose awareness. (orig.)

  16. BI-ground microstrip array coil vs. conventional microstrip array coil for mouse imaging at 7 tesla

    Science.gov (United States)

    Hernández, Ricardo; Terrones, M. A. López; Jakob, P. M.

    2012-10-01

    At high field strengths, the need for more efficient high frequency coils has grown. Since the radiation losses and the interaction between coil and sample increase proportionally to field strength, the quality factor (Q) and the sensitivity of the coil decrease as consequence of these negative effects. Since Zhang et al proposed in 2001 a new surface coil based on the microstrip transmission line for high frequency, different Tx-Rx phased arrays based on this concept have been already introduced in animal and whole body systems at high field strengths, each of them with different modifications in order to get better field homogeneity, SNR or isolation between coil elements in the array. All these arrays for animals systems have been built for rat imaging. One of these modifications is called BI-Ground Microstrip Array Coil (BIGMAC). The implementation of a smaller two-channel BIGMAC design for mouse imaging is studied and its performance compared to a two-channel conventional Microstrip array at 7 Tesla, the higher isolation by using BIGMAC elements in comparison with conventional Microstrip elements is shown in this work.

  17. Prognostic value of normal stress-only myocardial perfusion imaging: a comparison between conventional and CZT-based SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Yokota, Shu; Ottervanger, Jan Paul; Timmer, Jorik R. [Isala Hospital, Department of Cardiology, Zwolle (Netherlands); Mouden, Mohamed; Engbers, Elsemiek [Isala Hospital, Department of Cardiology, Zwolle (Netherlands); Isala Hospital, Department of Nuclear Medicine, Zwolle (Netherlands); Knollema, Siert; Jager, Pieter L. [Isala Hospital, Department of Nuclear Medicine, Zwolle (Netherlands)

    2016-02-15

    Single photon emission computed tomography (SPECT) myocardial perfusion imaging has proven to have prognostic importance in patients with suspected stable coronary artery disease (CAD). The recently introduced ultrafast cadmium zinc telluride (CZT)-based gamma cameras have been associated with less equivocal findings and more normal interpretations, allowing stress-only imaging to be performed more often. However, it is yet unclear whether normal stress-only CZT SPECT has comparable prognostic value as normally interpreted stress-only conventional SPECT. The study population consisted of 1,650 consecutive patients without known CAD with normal stress-only myocardial perfusion results with either conventional (n = 362) or CZT SPECT (n = 1,288). The incidence of major adverse cardiac events (MACE, all-cause death, non-fatal myocardial infarction and/or coronary revascularization) was compared between the conventional SPECT and CZT SPECT groups. Multivariable analyses using the Cox model were used to adjust for differences in baseline variables. Patients scanned with CZT were less often male (33 vs 39 %), had less often hypercholesterolaemia (41 vs 50 %) and had more often a family history of CAD (57 vs 49 %). At a median follow-up time of 37 months (interquartile range 28-45 months) MACE occurred in 68 patients. The incidence of MACE was 1.5 %/year in the CZT group, compared to 2.0 %/year in the conventional group (p = 0.08). After multivariate analyses, there was a trend to a lower incidence of MACE in the CZT SPECT group (hazard ratio 0.61, 95 % confidence interval 0.35-1.04, p = 0.07). The prognostic value of normal stress-only CZT SPECT is at least comparable and may be even better than that of normal conventional stress SPECT. (orig.)

  18. Pairing images of unhealthy and healthy foods with images of negative and positive health consequences: Impact on attitudes and food choice.

    Science.gov (United States)

    Hollands, Gareth J; Marteau, Theresa M

    2016-08-01

    To examine the impact of presenting images of foods paired with images of positive and negative health consequences of their consumption on food choice and attitudes. Participants (N = 711) were randomly allocated in a 2 × 3 factorial design (Food Type × Affective Valence) to 1 of 6 conditioning procedures that paired images of either energy-dense snack foods or fruit, with (a) images of negative health outcomes, (b) images of positive health outcomes, or (c) a no image control. The primary outcome was food choice assessed postintervention with a behavioral choice task. Secondary outcomes were implicit attitudes (assessed pre- and postintervention) and explicit attitudes (assessed postintervention). Presenting images of negative health outcomes led to more healthy food choices relative to control and positive image conditions, irrespective of whether they were paired with images of energy-dense snack foods or fruit. This relationship was partially mediated by changes in implicit and explicit attitudes. Images of positive health outcomes did not alter food choices. This study replicates and extends previous research showing that presenting images of negative health consequences increases healthy food choices. Because effects were elicited by manipulating affective valence irrespective of paired food type, these results appear more consistent with an explanation based on priming than on evaluative conditioning. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  19. Human Aortic Endothelial Cell Labeling with Positive Contrast Gadolinium Oxide Nanoparticles for Cellular Magnetic Resonance Imaging at 7 Tesla

    Directory of Open Access Journals (Sweden)

    Yasir Loai

    2012-03-01

    Full Text Available Positive T1 contrast using gadolinium (Gd contrast agents can potentially improve detection of labeled cells on magnetic resonance imaging (MRI. Recently, gadolinium oxide (Gd2O3 nanoparticles have shown promise as a sensitive T1 agent for cell labeling at clinical field strengths compared to conventional Gd chelates. The objective of this study was to investigate Gado CELLTrack, a commercially available Gd2O3 nanoparticle, for cell labeling and MRI at 7 T. Relaxivity measurements yielded r1 = 4.7 s−1 mM−1 and r2/r1 = 6.2. Human aortic endothelial cells were labeled with Gd2O3 at various concentrations and underwent MRI from 1 to 7 days postlabeling. The magnetic resonance relaxation times T1 and T2 of labeled cell pellets were measured. Cellular contrast agent uptake was quantified by inductively coupled plasma–atomic emission spectroscopy, which showed very high uptake compared to conventional Gd compounds. MRI demonstrated significant positive T1 contrast and stable labeling on cells. Enhancement was optimal at low Gd concentrations, attained in the 0.02 to 0.1 mM incubation concentration range (corresponding cell uptake was 7.26 to 34.1 pg Gd/cell. Cell viability and proliferation were unaffected at the concentrations tested and up to at least 3 days postlabeling. Gd2O3 is a promising sensitive and stable positive contrast agent for cellular MRI at 7 T.

  20. Detection and staging of chondromalacia patellae: relative efficacies of conventional MR imaging, MR arthrography, and CT arthrography.

    Science.gov (United States)

    Gagliardi, J A; Chung, E M; Chandnani, V P; Kesling, K L; Christensen, K P; Null, R N; Radvany, M G; Hansen, M F

    1994-09-01

    Chondromalacia patellae is a condition characterized by softening, fraying, and ulceration of patellar articular cartilage. We compare the sensitivity, specificity, and accuracy of conventional MR imaging, MR arthrography, and CT arthrography in detecting and staging this abnormality. Twenty-seven patients with pain in the anterior part of the knee were prospectively examined with MR imaging, including T1-weighted (650/16), proton density-weighted (2000/20), T2-weighted (2000/80), and spoiled two-dimensional gradient-recalled acquisition in the steady state (SPGR/)/35 degrees (51/10) with fat saturation pulse sequences. All were also examined with T1-weighted MR imaging after intraarticular injection of dilute gadopentetate dimeglumine and with double-contrast CT arthrography. Each imaging technique was evaluated independently by two observers, who reached a consensus interpretation. The signal characteristics of cartilage on MR images and contour abnormalities noted with all imaging techniques were evaluated and graded according to a modification of the classification of Shahriaree. Twenty-six of the 54 facets examined had chondromalacia shown by arthroscopy, which was used as the standard of reference. The sensitivity, specificity, and accuracy of each imaging technique in the diagnosis of each stage of chondromalacia patellae were determined and compared by using the McNemar two-tailed analysis. Arthroscopy showed that 28 facets were normal. Grade 1 chondromalacia patellae was diagnosed only with MR and CT arthrography in two (29%) of seven facets. Intermediate (grade 2 or 3) chondromalacia patellae was detected in two (13%) of 15 facets with T1-weighted and SPGR MR imaging, in three (20%) of 15 facets with proton density-weighted MR imaging, in seven (47%) of 15 facets with T2-weighted MR imaging, in 11 (73%) of 15 facets with CT arthrography, and in 12 (80%) of 15 facets with MR arthrography. Grade 4 was detected in three (75%) of four facets with T1-, proton

  1. Differentiation between early rheumatoid arthritis patients and healthy persons by conventional and dynamic contrast-enhanced magnetic resonance imaging

    DEFF Research Database (Denmark)

    Axelsen, Mette Bjørndal; Ejbjerg, B J; Hetland, M L

    2014-01-01

    OBJECTIVES: To identify the magnetic resonance imaging (MRI) parameter that best differentiates healthy persons and patients with early rheumatoid arthritis (RA), and to investigated responsiveness to treatment of various MRI parameters. METHOD: Conventional MRI and dynamic contrast-enhanced (DCE...

  2. Relative Panoramic Camera Position Estimation for Image-Based Virtual Reality Networks in Indoor Environments

    Science.gov (United States)

    Nakagawa, M.; Akano, K.; Kobayashi, T.; Sekiguchi, Y.

    2017-09-01

    Image-based virtual reality (VR) is a virtual space generated with panoramic images projected onto a primitive model. In imagebased VR, realistic VR scenes can be generated with lower rendering cost, and network data can be described as relationships among VR scenes. The camera network data are generated manually or by an automated procedure using camera position and rotation data. When panoramic images are acquired in indoor environments, network data should be generated without Global Navigation Satellite Systems (GNSS) positioning data. Thus, we focused on image-based VR generation using a panoramic camera in indoor environments. We propose a methodology to automate network data generation using panoramic images for an image-based VR space. We verified and evaluated our methodology through five experiments in indoor environments, including a corridor, elevator hall, room, and stairs. We confirmed that our methodology can automatically reconstruct network data using panoramic images for image-based VR in indoor environments without GNSS position data.

  3. RELATIVE PANORAMIC CAMERA POSITION ESTIMATION FOR IMAGE-BASED VIRTUAL REALITY NETWORKS IN INDOOR ENVIRONMENTS

    Directory of Open Access Journals (Sweden)

    M. Nakagawa

    2017-09-01

    Full Text Available Image-based virtual reality (VR is a virtual space generated with panoramic images projected onto a primitive model. In imagebased VR, realistic VR scenes can be generated with lower rendering cost, and network data can be described as relationships among VR scenes. The camera network data are generated manually or by an automated procedure using camera position and rotation data. When panoramic images are acquired in indoor environments, network data should be generated without Global Navigation Satellite Systems (GNSS positioning data. Thus, we focused on image-based VR generation using a panoramic camera in indoor environments. We propose a methodology to automate network data generation using panoramic images for an image-based VR space. We verified and evaluated our methodology through five experiments in indoor environments, including a corridor, elevator hall, room, and stairs. We confirmed that our methodology can automatically reconstruct network data using panoramic images for image-based VR in indoor environments without GNSS position data.

  4. Computer experiments on the imaging of point defects with the conventional transmission electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Krakow, W [Xerox Corp., Rochester, N.Y. (USA)

    1978-02-01

    To aid in the interpretation of high resolution electron micrographs of defect structures in crystals, computer-simulated dark-field electron micrographs have been obtained for a variety of point defects in metals. Interpretation of these images in terms of atomic positions and atom correlations becomes straightforward, and it is a simple matter to distinguish between real structural information and image artifacts produced by the phase contrast mechanism in the electron optical imaging process.

  5. Processing Distracting Non-face Emotional Images: No Evidence of an Age-Related Positivity Effect.

    Science.gov (United States)

    Madill, Mark; Murray, Janice E

    2017-01-01

    Cognitive aging may be accompanied by increased prioritization of social and emotional goals that enhance positive experiences and emotional states. The socioemotional selectivity theory suggests this may be achieved by giving preference to positive information and avoiding or suppressing negative information. Although there is some evidence of a positivity bias in controlled attention tasks, it remains unclear whether a positivity bias extends to the processing of affective stimuli presented outside focused attention. In two experiments, we investigated age-related differences in the effects of to-be-ignored non-face affective images on target processing. In Experiment 1, 27 older (64-90 years) and 25 young adults (19-29 years) made speeded valence judgments about centrally presented positive or negative target images taken from the International Affective Picture System. To-be-ignored distractor images were presented above and below the target image and were either positive, negative, or neutral in valence. The distractors were considered task relevant because they shared emotional characteristics with the target stimuli. Both older and young adults responded slower to targets when distractor valence was incongruent with target valence relative to when distractors were neutral. Older adults responded faster to positive than to negative targets but did not show increased interference effects from positive distractors. In Experiment 2, affective distractors were task irrelevant as the target was a three-digit array and did not share emotional characteristics with the distractors. Twenty-six older (63-84 years) and 30 young adults (18-30 years) gave speeded responses on a digit disparity task while ignoring the affective distractors positioned in the periphery. Task performance in either age group was not influenced by the task-irrelevant affective images. In keeping with the socioemotional selectivity theory, these findings suggest that older adults preferentially

  6. Combined SPECT/CT improves detection of initial bone invasion and determination of resection margins in squamous cell carcinoma of the head and neck compared to conventional imaging modalities

    Energy Technology Data Exchange (ETDEWEB)

    Kolk, A. [Technische Universitaet Muenchen, Klinikum rechts der Isar, Department of Oral and Maxillofacial Surgery, Munich (Germany); Klinikum rechts der Isar, Technische Universitaet Muenchen, Klinik und Poliklinik fuer Mund-Kiefer und Gesichtschirurgie, Muenchen (Germany); Schuster, T. [Technische Universitaet Muenchen, Klinikum rechts der Isar, Institute of Medical Statistics and Epidemiology, Munich (Germany); Chlebowski, A.; Kesting, M.; Bissinger, O.; Weitz, J. [Technische Universitaet Muenchen, Klinikum rechts der Isar, Department of Oral and Maxillofacial Surgery, Munich (Germany); Lange, P. [Technische Universitaet Muenchen, Klinikum rechts der Isar, Department of Diagnostic Radiology, Munich (Germany); Scheidhauer, K.; Schwaiger, M.; Dinges, J. [Technische Universitaet Muenchen, Klinikum rechts der Isar, Department of Nuclear Medicine, Munich (Germany)

    2014-07-15

    Knowledge of the presence and extent of bone infiltration is crucial for planning the resection of potential bone-infiltrating squamous cell carcinomas of the head and neck (HNSCC). Routinely, plain-film radiography, multislice computed tomography (MSCT) and magnetic resonance imaging (MRI) are used for preoperative staging, but they show relatively high rates of false-positive and false-negative findings. Scintigraphy with {sup 99m}Tc-bisphosphonate has the ability to show increased metabolic bone activity. If combined with anatomical imaging (e.g. (SPECT)/CT), it facilitates the precise localization of malignant bone lesions. The aim of this study was to analyse the indications and advantages of SPECT/CT compared with standard imaging modalities and histology with regard to specificity and sensitivity A longitudinally evaluated group of 30 patients with biopsy-proven HNSCC adjacent to the mandible underwent {sup 99m}Tc-bisphosphonate SPECT/CT, MRI, MSCT and conventional radiography before partial or rim resection of the mandible was performed. Bone infiltration was first evaluated with plain films, MSCT and MRI. In a second reading, SPECT/CT data were taken into account. The results (region and certainty of bone invasion) were evaluated among the different imaging modalities and finally compared with histological specimens from surgical resection as the standard of reference. For a better evaluation of the hybrid property of SPECT/CT, a retrospectively evaluated group of 20 additional patients with tumour locations similar to those of the longitudinally examined SPECT/CT group underwent SPECT, MSCT and MRI. To assess the influence of dental foci on the specificity of the imaging modalities, all patients were separated into two subgroups depending on the presence or absence of teeth in the area of potential tumour-bone contact. Histologically proven bone infiltration was found in 17 patients (57 %) when analysed by conventional imaging modalities. SPECT/CT data

  7. Combined SPECT/CT improves detection of initial bone invasion and determination of resection margins in squamous cell carcinoma of the head and neck compared to conventional imaging modalities

    International Nuclear Information System (INIS)

    Kolk, A.; Schuster, T.; Chlebowski, A.; Kesting, M.; Bissinger, O.; Weitz, J.; Lange, P.; Scheidhauer, K.; Schwaiger, M.; Dinges, J.

    2014-01-01

    Knowledge of the presence and extent of bone infiltration is crucial for planning the resection of potential bone-infiltrating squamous cell carcinomas of the head and neck (HNSCC). Routinely, plain-film radiography, multislice computed tomography (MSCT) and magnetic resonance imaging (MRI) are used for preoperative staging, but they show relatively high rates of false-positive and false-negative findings. Scintigraphy with 99m Tc-bisphosphonate has the ability to show increased metabolic bone activity. If combined with anatomical imaging (e.g. (SPECT)/CT), it facilitates the precise localization of malignant bone lesions. The aim of this study was to analyse the indications and advantages of SPECT/CT compared with standard imaging modalities and histology with regard to specificity and sensitivity A longitudinally evaluated group of 30 patients with biopsy-proven HNSCC adjacent to the mandible underwent 99m Tc-bisphosphonate SPECT/CT, MRI, MSCT and conventional radiography before partial or rim resection of the mandible was performed. Bone infiltration was first evaluated with plain films, MSCT and MRI. In a second reading, SPECT/CT data were taken into account. The results (region and certainty of bone invasion) were evaluated among the different imaging modalities and finally compared with histological specimens from surgical resection as the standard of reference. For a better evaluation of the hybrid property of SPECT/CT, a retrospectively evaluated group of 20 additional patients with tumour locations similar to those of the longitudinally examined SPECT/CT group underwent SPECT, MSCT and MRI. To assess the influence of dental foci on the specificity of the imaging modalities, all patients were separated into two subgroups depending on the presence or absence of teeth in the area of potential tumour-bone contact. Histologically proven bone infiltration was found in 17 patients (57 %) when analysed by conventional imaging modalities. SPECT/CT data revealed

  8. Diagnostic imaging of Klippel-Feil syndrome: conventional radiography, CT and MR imaging. Case report; Bildgebende Diagnostik des Klippel-Feil-Syndroms: Konventionelle Roentgenaufnahmen, CT und MRT. Fallbericht

    Energy Technology Data Exchange (ETDEWEB)

    Jochens, R. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Schubeus, P. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Steinkamp, H.J. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Menzhausen, L. [Abt. fuer Psychiatrie, Urban Krankenhaus, Berlin (Germany); Felix, R. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany)

    1993-12-31

    In two patients with Klippel-Feil syndrome, type II radiographic findings of the malformation are shown in the cervical spine and the craniocervical junction. Conventional X-rays of the cervical spine in the AP and lateral view and conventional tomography as well as CT of the cervical spine were obtained in both patients. One of the two patients additionally underwent MR imaging. Findings of the different imaging modalities are compared with each other. (orig.) [Deutsch] Anhand von zwei Patienten mit Klippel-Feil-Syndrom Typ II werden typische radiologische Befunde des Missbildungssyndroms im Bereich der Halswirbelsaeule und des kraniozervikalen Ueberganges dargestellt. Neben den konventionellen HWS-Roentgenaufnahmen und den konventionellen Schichtaufnahmen, wurden bei beiden Patienten ein CT der HWS und bei einem Patienten zusaetzlich ein MRT durchgefuehrt. Die Ergebnisse und Befunde der verschiedenen Untersuchungsverfahren werden einander gegenuebergestellt. (orig.)

  9. Case report: a position to delineate pelvic radionuclide uptake

    International Nuclear Information System (INIS)

    Giga, J.H.L.; Jimenez, T.; Lobred, S.K.

    1981-01-01

    An innovative position is described for patients undergoing technetium 99m bone imaging in the pelvic area. The position, called Gaga squat, requires the patient to sit on the scintillation camera face. This allows recognition of metastatic disease in areas which may be masked by bladder activity. The view may also be used to complement conventional views for studies such as TcO 4 testicular scans or gallium-67 scans

  10. A combined static-dynamic single-dose imaging protocol to compare quantitative dynamic SPECT with static conventional SPECT.

    Science.gov (United States)

    Sciammarella, Maria; Shrestha, Uttam M; Seo, Youngho; Gullberg, Grant T; Botvinick, Elias H

    2017-08-03

    SPECT myocardial perfusion imaging (MPI) is a clinical mainstay that is typically performed with static imaging protocols and visually or semi-quantitatively assessed for perfusion defects based upon the relative intensity of myocardial regions. Dynamic cardiac SPECT presents a new imaging technique based on time-varying information of radiotracer distribution, which permits the evaluation of regional myocardial blood flow (MBF) and coronary flow reserve (CFR). In this work, a preliminary feasibility study was conducted in a small patient sample designed to implement a unique combined static-dynamic single-dose one-day visit imaging protocol to compare quantitative dynamic SPECT with static conventional SPECT for improving the diagnosis of coronary artery disease (CAD). Fifteen patients (11 males, four females, mean age 71 ± 9 years) were enrolled for a combined dynamic and static SPECT (Infinia Hawkeye 4, GE Healthcare) imaging protocol with a single dose of 99m Tc-tetrofosmin administered at rest and a single dose administered at stress in a one-day visit. Out of 15 patients, eleven had selective coronary angiography (SCA), 8 within 6 months and the rest within 24 months of SPECT imaging, without intervening symptoms or interventions. The extent and severity of perfusion defects in each myocardial region was graded visually. Dynamically acquired data were also used to estimate the MBF and CFR. Both visually graded images and estimated CFR were tested against SCA as a reference to evaluate the validity of the methods. Overall, conventional static SPECT was normal in ten patients and abnormal in five patients, dynamic SPECT was normal in 12 patients and abnormal in three patients, and CFR from dynamic SPECT was normal in nine patients and abnormal in six patients. Among those 11 patients with SCA, conventional SPECT was normal in 5, 3 with documented CAD on SCA with an overall accuracy of 64%, sensitivity of 40% and specificity of 83%. Dynamic SPECT image

  11. Magnetic resonance angiography for patients with positional vertigo

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Toru; Tominaga, Satoru; Fujiki, Hiroya (Takarazuka City Hospital, Hyogo (Japan)); Kumoi, Takeo

    1993-11-01

    Magnetic resonance angiography (MRA) can image the blood vessels without invasion. Using MRA, we studied the vascular morphology of the vertebral artery in patients with positional nystagmus and vertigo. Fifteen patients without vestibular disorder such as benign positional vertigo were examined. Six cases underwent conventional vertebral angiography, including digital subtraction angiography (DSA) for comparison with MRA. In all cases. we observed the vertebral artery from the bifurcation to the basilar artery with MRA. In 12 cases, abnormal findings of elongation, bending, narrowing or obstruction of the vertebral artery were found. In five cases, arterial compression and elongation increased in association with head rotation. A difference in the vessel diameter on each side was observed in 4 cases. Accordingly, some abnormal vessels were found in 14 of 15 cases in our study. This rate was very close to previous results obtained with conventional angiography. In two cases, MRA findings differed from conventional angiography due to peculiar artifacts of MRA. Therefore, MRA may be the first choice for the patients with vertigo, followed by conventional angiography, if necessary. (author).

  12. Magnetic resonance angiography for patients with positional vertigo

    International Nuclear Information System (INIS)

    Seo, Toru; Tominaga, Satoru; Fujiki, Hiroya; Kumoi, Takeo.

    1993-01-01

    Magnetic resonance angiography (MRA) can image the blood vessels without invasion. Using MRA, we studied the vascular morphology of the vertebral artery in patients with positional nystagmus and vertigo. Fifteen patients without vestibular disorder such as benign positional vertigo were examined. Six cases underwent conventional vertebral angiography, including digital subtraction angiography (DSA) for comparison with MRA. In all cases. we observed the vertebral artery from the bifurcation to the basilar artery with MRA. In 12 cases, abnormal findings of elongation, bending, narrowing or obstruction of the vertebral artery were found. In five cases, arterial compression and elongation increased in association with head rotation. A difference in the vessel diameter on each side was observed in 4 cases. Accordingly, some abnormal vessels were found in 14 of 15 cases in our study. This rate was very close to previous results obtained with conventional angiography. In two cases, MRA findings differed from conventional angiography due to peculiar artifacts of MRA. Therefore, MRA may be the first choice for the patients with vertigo, followed by conventional angiography, if necessary. (author)

  13. Diagnostic performance of the three-dimensional fast spin echo-Cube sequence in comparison with a conventional imaging protocol in evaluation of the lachrymal drainage system

    International Nuclear Information System (INIS)

    Zhang, Jing; Chen, Lang; Wang, Qiu-Xia; Zhu, Wen-Zhen; Luo, Xin; Peng, Li; Liu, Rong; Xiong, Wei

    2015-01-01

    To compare the three-dimensional (3D)-fast spin-echo (FSE)-Cube with a conventional imaging protocol in evaluation of dacryostenosis. Thirty-three patients with epiphora underwent examinations using Cube magnetic resonance dacryocystography (MRD) and a conventional protocol, which included 3D fast-recovery fast spin-echo (FRFSE) MRD and two-dimensional (2D)-FSE sequences at 3.0 T. Using lachrymal endoscopic findings as the reference standard, we calculated the sensitivity and specificity of both protocols for detecting lachrymal drainage system (LDS) obstruction and their accuracies in depicting the level of obstruction. Comparable coronal and axial images were selected for bot sequences. Two neuroradiologists graded paired images for blurring, artefacts, anatomic details, and overall image quality. The two methods showed no significant difference in sensitivity (89.5 % vs. 94.7 %; p =0.674), specificity (64.3 %; p =1) or accuracy (86.8 %; p =1) in detecting or depicting LDS obstruction. Blurring and artefacts were significantly better on 2D-FSE images (p 0.05). In comparison with the conventional protocol, Cube MRD demonstrates satisfactory image quality and similar diagnostic capability for cases of possible LDS disease. (orig.)

  14. Reducing Field Distortion in Magnetic Resonance Imaging

    Science.gov (United States)

    Eom, Byeong Ho; Penanen, Konstantin; Hahn, Inseob

    2010-01-01

    A concept for a magnetic resonance imaging (MRI) system that would utilize a relatively weak magnetic field provides for several design features that differ significantly from the corresponding features of conventional MRI systems. Notable among these features are a magnetic-field configuration that reduces (relative to the conventional configuration) distortion and blurring of the image, the use of a superconducting quantum interference device (SQUID) magnetometer as the detector, and an imaging procedure suited for the unconventional field configuration and sensor. In a typical application of MRI, a radio-frequency pulse is used to excite precession of the magnetic moments of protons in an applied magnetic field, and the decaying precession is detected for a short time following the pulse. The precession occurs at a resonance frequency proportional to the strengths of the magnetic field and the proton magnetic moment. The magnetic field is configured to vary with position in a known way; hence, by virtue of the aforesaid proportionality, the resonance frequency varies with position in a known way. In other words, position is encoded as resonance frequency. MRI using magnetic fields weaker than those of conventional MRI offers several advantages, including cheaper and smaller equipment, greater compatibility with metallic objects, and higher image quality because of low susceptibility distortion and enhanced spin-lattice-relaxation- time contrast. SQUID MRI is being developed into a practical MRI method for applied magnetic flux densities of the order of only 100 T

  15. Digital luminescent radiography: A substitute for conventional chest radiography?

    International Nuclear Information System (INIS)

    Neufang, K.F.R.; Krug, B.; Lorenz, R.; Steinbrich, W.

    1990-01-01

    The image quality of digital luminescent radiography (DLR) is sufficient for routine biplane chest radiography and for follow-up studies of heart size, pulmonary congestion, coin lesions, infiltrations, atelectasis, pleural effusions, and mediastinal and hilar lymph node enlargement. Chest radiography in the intensive care unit may in most cases be performed using the DLR technique. there is no need for repeat shots because of incorrect exposure, and the position of catheters, tubes, pacemakers, drains and artificial heart valves, the mediastinum, and the retrocardiac areas of the left lung are more confidently assessed on the edge-enhanced DLR films than on conventional films. Nevertheless, DLR is somewhat inferior to conventional film-screen radiography of the chest as it can demonstrate or rule out subtle pulmonary interstitial disease less confidently. There is no reduction of radiation exposure of the chest in DLR compared with modern film-screen systems. As a consequence, DLR is presently not in a position to replace traditional film-screen radiography of the chest completely. (orig.) [de

  16. Associations Between Positive Body Image, Sexual Liberalism, and Unconventional Sexual Practices in U.S. Adults.

    Science.gov (United States)

    Swami, Viren; Weis, Laura; Barron, David; Furnham, Adrian

    2017-11-01

    While studies have documented robust relationships between body image and sexual health outcomes, few studies have looked beyond sexual functioning in women. Here, we hypothesized that more positive body image would be associated with greater sexual liberalism and more positive attitudes toward unconventional sexual practices. An online sample of 151 women and 164 men from the U.S. completed measures of sexual liberalism, attitudes toward unconventional sexual practices, and indices of positive body image (i.e., body appreciation, body acceptance by others, body image flexibility, and body pride), and provided their demographic details. Regression analyses indicated that, once the effects of sexual orientation, relationship status, age, and body mass index had been accounted for, higher body appreciation was significantly associated with greater sexual liberalism in women and men. Furthermore, higher body appreciation and body image flexibility were significantly associated with more positive attitudes toward unconventional sexual practices in women and men. These results may have implications for scholars working from a sex-positive perspective, particularly in terms of understanding the role body image plays in sexual attitudes and behaviors.

  17. The impact of reorienting cone-beam computed tomographic images in varied head positions on the coordinates of anatomical landmarks

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Hun; Jeong, Ho Gul; Hwang, Jae Joon; Lee, Jung Hee; Han, Sang Sun [Dept. of Oral and Maxillofacial Radiology, Yonsei University, College of Dentistry, Seoul (Korea, Republic of)

    2016-06-15

    The aim of this study was to compare the coordinates of anatomical landmarks on cone-beam computed tomographic (CBCT) images in varied head positions before and after reorientation using image analysis software. CBCT images were taken in a normal position and four varied head positions using a dry skull marked with 3 points where gutta percha was fixed. In each of the five radiographic images, reference points were set, 20 anatomical landmarks were identified, and each set of coordinates was calculated. Coordinates in the images from the normally positioned head were compared with those in the images obtained from varied head positions using statistical methods. Post-reorientation coordinates calculated using a three-dimensional image analysis program were also compared to the reference coordinates. In the original images, statistically significant differences were found between coordinates in the normal-position and varied-position images. However, post-reorientation, no statistically significant differences were found between coordinates in the normal-position and varied-position images. The changes in head position impacted the coordinates of the anatomical landmarks in three-dimensional images. However, reorientation using image analysis software allowed accurate superimposition onto the reference positions.

  18. 18F-FDG-PET/CT in patients with breast cancer and rising Ca 15-3 with negative conventional imaging: A multicentre study

    International Nuclear Information System (INIS)

    Grassetto, Gaia; Fornasiero, Adriano; Otello, Daniele; Bonciarelli, Giorgio; Rossi, Elena; Nashimben, Ottorino; Minicozzi, Anna Maria; Crepaldi, Giorgio; Pasini, Felice; Facci, Enzo; Mandoliti, Giovanni; Marzola, Maria Cristina; Al-Nahhas, Adil; Rubello, Domenico

    2011-01-01

    Objectives: Breast cancer is the second cause of death in women in Europe and North America. The mortality of this disease can be reduced with effective therapy and regular follow up to detect early recurrence. Tumor markers are sensitive in detecting recurrent or residual disease but imaging is required to customize the therapeutic option. Rising tumor markers and negative conventional imaging (US, X-mammography, CT and MR) poses a management problem. Our aim is to assess the role of 18 F-FDG-PET/CT in the management of post-therapy patients with rising markers but negative conventional imaging. Materials and methods: In the period from January 2008 to September 2009, 89 female patients with breast cancer who developed post-therapy rising markers (serum Ca 15-3 levels = 64.8 ± 16.3 U/mL) but negative clinical examination and conventional imaging were investigated with 18 F-FDG-PET/CT. Results: Tumor deposits were detected in 40/89 patients in chest wall, internal mammary nodes, lungs, liver and skeleton. The mean SUVmax value calculated in these lesions was 6.6 ± 1.7 (range 3.1–12.8). In 23/40 patients solitary small lesion were amenable to radical therapy. In 7 out of these 23 patients a complete disease remission lasting more than 1 year was observed. Conclusions: 18 F-FDG-PET/CT may have a potential role in asymptomatic patients with rising markers and negative conventional imaging. Our findings agree with other studies in promoting regular investigations such as tumor markers and 18 F-FDG-PET/CT rather than awaiting the developments of physical symptoms as suggested by current guidelines since the timely detection of early recurrence may have a major impact on therapy and survival.

  19. Optimization of patient protection using rare earth screen in conventional imaging procedure

    International Nuclear Information System (INIS)

    Inkoom, S.; Schandorf, C.; Fletcher, J.J.

    2008-01-01

    The purpose of this study was to optimize patient protection using rare earth screen of speed 400 in place of conventional screen-film of speed 200. The entrance surface dose (ESD) for the two screen-film systems was determined for patients undergoing simple radiographic examinations (chest, lumbar spine and pelvis series). The determination of the ESD included backscatter factors. The ESD was the optimizing parameter and its trade off with the image quality assessment, which was surveyed based on the information obtained through standardized questionnaire. The estimated ESDs were compared with reference levels set by the Community of European Commission (CEC) for a standard adult patient. For chest PA, ESD estimates were lower than the CEC reference levels whilst that of lumbar spine AP and LAT and pelvis AP were high. Upon the adoption of rare earth screen of speed 400, a dose reduction of 33% for chest, 17% for lumbar spine and 28% for pelvis examinations was achieved. From the observations made from this study, some corrective actions such as equipment quality control of parameters that affect patient dose and image quality like kVp accuracy and consistency, mAs accuracy and consistency, optimal film processing conditions, regular film reject analysis to detect and minimize the root causes and contributory factors to poor image quality and periodic training of staff on dose reduction techniques must be undertaken. Regular assessment of patient dose and image quality, equipment quality control, adoption of faster rare earth screens and optimum radiographic technique are therefore recommended in order to achieve optimization goals. (author)

  20. PET imaging for the quantification of biologically heterogeneous tumours: measuring the effect of relative position on image-based quantification of dose-painting targets

    International Nuclear Information System (INIS)

    McCall, Keisha C; Barbee, David L; Kissick, Michael W; Jeraj, Robert

    2010-01-01

    Quantitative imaging of tumours represents the foundation of customized therapies and adaptive patient care. As such, we have investigated the effect of patient positioning errors on the reproducibility of images of biologically heterogeneous tumours generated by a clinical PET/CT system. A commercial multi-slice PET/CT system was used to acquire 2D and 3D PET images of a phantom containing multiple spheres of known volumes and known radioactivity concentrations and suspended in an aqueous medium. The spheres served as surrogates for sub-tumour regions of biological heterogeneities with dimensions of 5-15 mm. Between image acquisitions, a motorized-arm was used to reposition the spheres in 1 mm intervals along either the radial or the axial direction. Images of the phantom were reconstructed using typical diagnostic reconstruction techniques, and these images were analysed to characterize and model the position-dependent changes in contrast recovery. A simulation study was also conducted to investigate the effect of patient position on the reproducibility of PET imaging of biologically heterogeneous head and neck (HN) tumours. For this simulation study, we calculated the changes in image intensity values that would occur with changes in the relative position of the patients at the time of imaging. PET images of two HN patients were used to simulate an imaging study that incorporated set-up errors that are typical for HN patients. One thousand randomized positioning errors were investigated for each patient. As a result of the phantom study, a position-dependent trend was identified for measurements of contrast recovery of small objects. The peak contrast recovery occurred at radial and axial positions that coincide with the centre of the image voxel. Conversely, the minimum contrast recovery occurred when the object was positioned at the edges of the image voxel. Changing the position of high contrast spheres by one-half the voxel dimension lead to errors in the

  1. Comparison of daily megavoltage electronic portal imaging or kilovoltage imaging with marker seeds to ultrasound imaging or skin marks for prostate localization and treatment positioning in patients with prostate cancer

    International Nuclear Information System (INIS)

    Serago, Christopher F.; Buskirk, Steven J.; Igel, Todd C.; Gale, Ashley A.; Serago, Nicole E.; Earle, John D.

    2006-01-01

    Purpose: To compare the accuracy of imaging modalities, immobilization, localization, and positioning techniques in patients with prostate cancer. Methods and Materials: Thirty-five patients with prostate cancer had gold marker seeds implanted transrectally and were treated with fractionated radiotherapy. Twenty of the 35 patients had limited immobilization; the remaining had a vacuum-based immobilization. Patient positioning consisted of alignment with lasers to skin marks, ultrasound or kilovoltage X-ray imaging, optical guidance using infrared reflectors, and megavoltage electronic portal imaging (EPI). The variance of each positioning technique was compared to the patient position determined from the pretreatment EPI. Results: With limited immobilization, the average difference between the skin marks' laser position and EPI pretreatment position is 9.1 ± 5.3 mm, the average difference between the skin marks' infrared position and EPI pretreatment position is 11.8 ± 7.2 mm, the average difference between the ultrasound position and EPI pretreatment position is 7.0 ± 4.6 mm, the average difference between kV imaging and EPI pretreatment position is 3.5 ± 3.1 mm, and the average intrafraction movement during treatment is 3.4 ± 2.7 mm. For the patients with the vacuum-style immobilization, the average difference between the skin marks' laser position and EPI pretreatment position is 10.7 ± 4.6 mm, the average difference between kV imaging and EPI pretreatment position is 1.9 ± 1.5 mm, and the average intrafraction movement during treatment is 2.1 ± 1.5 mm. Conclusions: Compared with use of skin marks, ultrasound imaging for positioning provides an increased degree of agreement to EPI-based positioning, though not as favorable as kV imaging fiducial seeds. Intrafraction movement during treatment decreases with improved immobilization

  2. In vivo characterization of a new abdominal aortic aneurysm mouse model with conventional and molecular magnetic resonance imaging

    NARCIS (Netherlands)

    Klink, Ahmed; Heynens, Joeri; Herranz, Beatriz; Lobatto, Mark E.; Arias, Teresa; Sanders, Honorius M. H. F.; Strijkers, Gustav J.; Merkx, Maarten; Nicolay, Klaas; Fuster, Valentin; Tedgui, Alain; Mallat, Ziad; Mulder, Willem J. M.; Fayad, Zahi A.

    2011-01-01

    The goal of this study was to use noninvasive conventional and molecular magnetic resonance imaging (MRI) to detect and characterize abdominal aortic aneurysms (AAAs) in vivo. Collagen is an essential constituent of aneurysms. Noninvasive MRI of collagen may represent an opportunity to help detect

  3. A clinical study for radiotherapy positioning with references images on CT simulator

    International Nuclear Information System (INIS)

    Yang Bo; Sun Xiaoyang; Luo Huiqun; Wu Hong; Pang Haowen

    2011-01-01

    Objective: To explore a new method of comparing the references images first to enhance the precision of the central point of the radiation treatment planning (RTP), try to establish a reference standard for this method in the nasopharyngeal cancer (NPC) and carcinoma of utercin cervix in the work of position verification. Methods: For 50 RTPs of NPC and 20 RTPs of carcinoma of utercin cervix, the reference-CT-images in set-up and in position verification were compared, and to measure the difference between the two images. Then, in the same way, compare and measure the difference in the central-point-images. Results: For NPC, there was over 90% RTPs in which every difference measured was less than 2 mm;for carcinoma of utercin cervix, over 80% RTPs meet the criterion:the value of ΔMU 1 ' or ΔMU 2 ' was less than 5 mm and the others are less than 3 mm. Conclusions: By comparing the references-CT-images in set-up and in position verification, the precision of the central point of the RTP is enhanced. The marks on the skin become more credible. So, it is feasible to perform the criterions in the work of position verification: for NPC every difference measured is less than 2 mm; for carcinoma of utercin cervix the value of ΔMU 1 ' or ΔMU 2 ' is less than 5 mm and the others are less than 3 mm. (authors)

  4. Evaluation of electrode position in deep brain stimulation by image fusion (MRI and CT)

    Energy Technology Data Exchange (ETDEWEB)

    Barnaure, I.; Lovblad, K.O.; Vargas, M.I. [Geneva University Hospital, Department of Neuroradiology, Geneva 14 (Switzerland); Pollak, P.; Horvath, J.; Boex, C.; Burkhard, P. [Geneva University Hospital, Department of Neurology, Geneva (Switzerland); Momjian, S. [Geneva University Hospital, Department of Neurosurgery, Geneva (Switzerland); Remuinan, J. [Geneva University Hospital, Department of Radiology, Geneva (Switzerland)

    2015-09-15

    Imaging has an essential role in the evaluation of correct positioning of electrodes implanted for deep brain stimulation (DBS). Although MRI offers superior anatomic visualization of target sites, there are safety concerns in patients with implanted material; imaging guidelines are inconsistent and vary. The fusion of postoperative CT with preoperative MRI images can be an alternative for the assessment of electrode positioning. The purpose of this study was to assess the accuracy of measurements realized on fused images (acquired without a stereotactic frame) using a manufacturer-provided software. Data from 23 Parkinson's disease patients who underwent bilateral electrode placement for subthalamic nucleus (STN) DBS were acquired. Preoperative high-resolution T2-weighted sequences at 3 T, and postoperative CT series were fused using a commercially available software. Electrode tip position was measured on the obtained images in three directions (in relation to the midline, the AC-PC line and an AC-PC line orthogonal, respectively) and assessed in relation to measures realized on postoperative 3D T1 images acquired at 1.5 T. Mean differences between measures carried out on fused images and on postoperative MRI lay between 0.17 and 0.97 mm. Fusion of CT and MRI images provides a safe and fast technique for postoperative assessment of electrode position in DBS. (orig.)

  5. SU-E-J-15: Automatically Detect Patient Treatment Position and Orientation in KV Portal Images

    International Nuclear Information System (INIS)

    Qiu, J; Yang, D

    2015-01-01

    Purpose: In the course of radiation therapy, the complex information processing workflow will Result in potential errors, such as incorrect or inaccurate patient setups. With automatic image check and patient identification, such errors could be effectively reduced. For this purpose, we developed a simple and rapid image processing method, to automatically detect the patient position and orientation in 2D portal images, so to allow automatic check of positions and orientations for patient daily RT treatments. Methods: Based on the principle of portal image formation, a set of whole body DRR images were reconstructed from multiple whole body CT volume datasets, and fused together to be used as the matching template. To identify the patient setup position and orientation shown in a 2D portal image, the 2D portal image was preprocessed (contrast enhancement, down-sampling and couch table detection), then matched to the template image so to identify the laterality (left or right), position, orientation and treatment site. Results: Five day’s clinical qualified portal images were gathered randomly, then were processed by the automatic detection and matching method without any additional information. The detection results were visually checked by physicists. 182 images were correct detection in a total of 200kV portal images. The correct rate was 91%. Conclusion: The proposed method can detect patient setup and orientation quickly and automatically. It only requires the image intensity information in KV portal images. This method can be useful in the framework of Electronic Chart Check (ECCK) to reduce the potential errors in workflow of radiation therapy and so to improve patient safety. In addition, the auto-detection results, as the patient treatment site position and patient orientation, could be useful to guide the sequential image processing procedures, e.g. verification of patient daily setup accuracy. This work was partially supported by research grant from

  6. SU-E-J-15: Automatically Detect Patient Treatment Position and Orientation in KV Portal Images

    Energy Technology Data Exchange (ETDEWEB)

    Qiu, J [Washington University in St Louis, Taian, Shandong (China); Yang, D [Washington University School of Medicine, St Louis, MO (United States)

    2015-06-15

    Purpose: In the course of radiation therapy, the complex information processing workflow will Result in potential errors, such as incorrect or inaccurate patient setups. With automatic image check and patient identification, such errors could be effectively reduced. For this purpose, we developed a simple and rapid image processing method, to automatically detect the patient position and orientation in 2D portal images, so to allow automatic check of positions and orientations for patient daily RT treatments. Methods: Based on the principle of portal image formation, a set of whole body DRR images were reconstructed from multiple whole body CT volume datasets, and fused together to be used as the matching template. To identify the patient setup position and orientation shown in a 2D portal image, the 2D portal image was preprocessed (contrast enhancement, down-sampling and couch table detection), then matched to the template image so to identify the laterality (left or right), position, orientation and treatment site. Results: Five day’s clinical qualified portal images were gathered randomly, then were processed by the automatic detection and matching method without any additional information. The detection results were visually checked by physicists. 182 images were correct detection in a total of 200kV portal images. The correct rate was 91%. Conclusion: The proposed method can detect patient setup and orientation quickly and automatically. It only requires the image intensity information in KV portal images. This method can be useful in the framework of Electronic Chart Check (ECCK) to reduce the potential errors in workflow of radiation therapy and so to improve patient safety. In addition, the auto-detection results, as the patient treatment site position and patient orientation, could be useful to guide the sequential image processing procedures, e.g. verification of patient daily setup accuracy. This work was partially supported by research grant from

  7. Virtual Reality Aided Positioning of Mobile C-Arms for Image-Guided Surgery

    Directory of Open Access Journals (Sweden)

    Zhenzhou Shao

    2014-06-01

    Full Text Available For the image-guided surgery, the positioning of mobile C-arms is a key technique to take X-ray images in a desired pose for the confirmation of current surgical outcome. Unfortunately, surgeons and patient often suffer the radiation exposure due to the repeated imaging when the X-ray image is of poor quality or not captured at a good projection view. In this paper, a virtual reality (VR aided positioning method for the mobile C-arm is proposed by the alignment of 3D surface model of region of interest and preoperative anatomy, so that a reference pose of the mobile C-arm with respect to the inside anatomy can be figured out from outside view. It allows a one-time imaging from the outside view to greatly reduce the additional radiation exposure. To control the mobile C-arm to the desired pose, the mobile C-arm is modeled as a robotic arm with a movable base. Experiments were conducted to evaluate the accuracy of appearance model and precision of mobile C-arm positioning. The appearance model was reconstructed with the average error of 2.16 mm. One-time imaging of mobile C-arm was achieved, and new modeling of mobile C-arm with 8 DoFs enlarges the working space in the operating room.

  8. The effects of breathing motion on DCE-MRI images: Phantom studies simulating respiratory motion to compare CAIPARINHA-VIBE, radial VIBE, and conventional VIBE

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chang Kyung; Seo, Nieun; Kim, Bohyun; Huh, Jimi; Kim, Jeong Kon; Lee, Seung Soo; KIm, Kyung Won [Dept. of Radiology, and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Kim, In Seong [Siemens Healthcare Korea, Seoul (Korea, Republic of); Nickel, Dominik [MR Application Predevelopment, Siemens Healthcare, Erlangen (Germany)

    2017-04-15

    To compare the breathing effects on dynamic contrast-enhanced (DCE)-MRI between controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA)-volumetric interpolated breath-hold examination (VIBE), radial VIBE with k-space-weighted image contrast view-sharing (radial-VIBE), and conventional VIBE (c-VIBE) sequences using a dedicated phantom experiment. We developed a moving platform to simulate breathing motion. We conducted dynamic scanning on a 3T machine (MAGNETOM Skyra, Siemens Healthcare) using CAIPIRINHA-VIBE, radial-VIBE, and c-VIBE for six minutes per sequence. We acquired MRI images of the phantom in both static and moving modes, and we also obtained motion-corrected images for the motion mode. We compared the signal stability and signal-to-noise ratio (SNR) of each sequence according to motion state and used the coefficients of variation (CoV) to determine the degree of signal stability. With motion, CAIPIRINHA-VIBE showed the best image quality, and the motion correction aligned the images very well. The CoV (%) of CAIPIRINHA-VIBE in the moving mode (18.65) decreased significantly after the motion correction (2.56) (p < 0.001). In contrast, c-VIBE showed severe breathing motion artifacts that did not improve after motion correction. For radial-VIBE, the position of the phantom in the images did not change during motion, but streak artifacts significantly degraded image quality, also after motion correction. In addition, SNR increased in both CAIPIRINHA-VIBE (from 3.37 to 9.41, p < 0.001) and radial-VIBE (from 4.3 to 4.96, p < 0.001) after motion correction. CAIPIRINHA-VIBE performed best for free-breathing DCE-MRI after motion correction, with excellent image quality.

  9. A review of 99mTc labeled myocardial imaging agents for tumor-positive imaging

    International Nuclear Information System (INIS)

    Xing Shian; Zhang Yongxue; An Rui

    2002-01-01

    The tumor-positive imaging with high sensitivity and specificity was useful in primary tumor and recurrences and metastases. The 99m Tc labeled myocardial imaging agents are easily available and stable and the radiochemical purity is high. 99m Tc is the preferred choice in routine works because its physical properties. The preparation, quality control, mechanism of accumulation and the clinical use of 99m Tc-sestamibi, 99m Tc-tetrofosmin, 99m Tc-furifosmin, and 99m Tc-N-NOET were reviewed

  10. Relapse surveillance in AFP-positive hepatoblastoma: re-evaluating the role of imaging

    Energy Technology Data Exchange (ETDEWEB)

    Rojas, Yesenia; Vasudevan, Sanjeev A.; Nuchtern, Jed G. [Baylor College of Medicine, Pediatric Surgery Division, Michael E. DeBakey Department of Surgery, Texas Children' s Hospital, Houston, TX (United States); Guillerman, R.P. [Baylor College of Medicine, Department of Pediatric Radiology, Texas Children' s Hospital, Houston, TX (United States); Zhang, Wei [Texas Children' s Hospital, Surgical Outcomes Center, Houston, TX (United States); Thompson, Patrick A. [Baylor College of Medicine, Hematology-Oncology Division, Department of Pediatrics, Texas Children' s Cancer Center, Texas Children' s Hospital, Houston, TX (United States); University of North Carolina, Hematology-Oncology Division, Department of Pediatrics, North Carolina Children' s Hospital, Chapel Hill, NC (United States)

    2014-10-15

    Children with hepatoblastoma routinely undergo repetitive surveillance imaging, with CT scans for several years after therapy, increasing the risk of radiation-induced cancer. The purpose of this study was to determine the utility of surveillance CT scans compared to serum alpha-fetoprotein (AFP) levels for the detection of hepatoblastoma relapse. This was a retrospective study of all children diagnosed with AFP-positive hepatoblastoma from 2001 to 2011 at a single institution. Twenty-six children with hepatoblastoma were identified, with a mean age at diagnosis of 2 years 4 months (range 3 months to 11 years). Mean AFP level at diagnosis was 132,732 ng/ml (range 172.8-572,613 ng/ml). Five of the 26 children had hepatoblastoma relapse. A total of 105 imaging exams were performed following completion of therapy; 88 (84%) CT, 8 (8%) MRI, 5 (5%) US and 4 (4%) FDG PET/CT exams. A total of 288 alpha-fetoprotein levels were drawn, with a mean of 11 per child. The AFP level was elevated in all recurrences and no relapses were detected by imaging before AFP elevation. Two false-positive AFP levels and 15 false-positive imaging exams were detected. AFP elevation was found to be significantly more specific than PET/CT and CT imaging at detecting relapse. We recommend using serial serum AFP levels as the preferred method of surveillance in children with AFP-positive hepatoblastoma, reserving imaging for the early postoperative period, for children at high risk of relapse, and for determination of the anatomical site of clinically suspected recurrence. Given the small size of this preliminary study, validation in a larger patient population is warranted. (orig.)

  11. Lumbosacral lipoma : gadolinium-enhanced fat saturation T1 weighted MR image is necessary?

    International Nuclear Information System (INIS)

    Yoon, Man Won; Kim, Hyun Chul; Chung, Tae Woong; Seo, Jeong Jin; Chung, Gwang Woo; Kim, Yun Hyeon; Kim, Jae Kyu; Park, Jin Gyoon; Kang, Heoung Keun

    1999-01-01

    To evaluate the usefulness of contrast-enhanced fat saturation T1-weighted imaging for the evaluation of spinal lipoma, compared with clinical symptoms and surgical findings. Ten patients with lipomyelomeningocele, confirmed by surgery, were included in this study. In all cases, conventional spin echo T1-and T2-weighted MR imaging, and contrast-enhanced fat saturation T1-weighted imaging was performed to evaluate clinical symptoms, the position of the conus medullaris, the presence of cord tethering, and associated anomalies, and to compare the relative usefulness of the techniques. All ten patients were suffering from lipomyelomeningocele without filum terminale fibrolipoma or intradural lipoma. All cases were associated with cord tethering. As associated anomalies, there were seven cases of syringomyelia without hydrocephalus or anorectal anomaly. To evaluate the position of the spinal conus and the presence of cord tethering, conventional T1-weighted imaging was more useful than the contrast-enhanced fat saturation equivalent. In patients with early-stage spinal lipoma, MRI is useful for evaluation of the causes and position of cord tethering and associated anomalies Our results suggest that contrast-enhanced fat saturation T1-weighted images do not provide additional information concerning spinal lipoma, and that for the diagnosis of this condition, conventional T1 and T2-weighted images are more useful than those obtained by contrast-enhanced fat saturation T1-weighted imaging

  12. Comment on ''Perfect imaging with positive refraction in three dimensions''

    International Nuclear Information System (INIS)

    Merlin, R.

    2010-01-01

    Leonhardt and Philbin [Phys. Rev. A 81, 011804(R) (2010)] have recently constructed a mathematical proof that the Maxwell's fish-eye lens provides perfect imaging of electromagnetic waves without negative refraction. In this comment, we argue that the unlimited resolution is an artifact of having introduced an unphysical drain at the position of the geometrical image. The correct solution gives focusing consistent with the standard diffraction limit.

  13. Patient dosimetry and image quality in conventional diagnostic radiology. An experience from a local Serbian hospital

    International Nuclear Information System (INIS)

    Olivera Ciraj-Bjelac; Milojko Kovacevic; Dusko Kosutic; Milan Loncar; Dajana Veljkovic

    2007-01-01

    Complete test of publication follows. The optimization of image quality vs. patient dose ins an important task in medical imaging. Maximal validity of optimization has to be based on clinical images. Simultaneous measurement of patient dose levels and image quality assessment is used to investigate possibilities for dose reduction and maintain image quality. The survey was conducted in a local hospital performing more than 60000 images annually and representing typical Serbian practice. For four most frequent diagnostic procedures (seven projections) patient exposure was measured using kerma area product meter. Image quality was assessed by experienced radiologists using 'European Guidelines on Quality Criteria for Diagnostic Radiographic Images'. Following examination types were included into the survey: chest PA, chest LAT, pelvis AP, lumbar spine AP, lumbar spine LAT and LSJ, skull PA and skull LAT. Comparing actual radiographic technique with recommended technique in European Guidelines, modification of practice was proposed and implemented and image quality was re-assessed. At least 10 adult patients were followed for each projection, before and after corrective actions. Large dose saving without compromising diagnostic information were found for some examination types, showing that this simple method is very efficient dose reduction tool in conventional diagnostic radiology. Also, need for staff training and difficulties related to practical implementation of optimization methods in Serbia were discussed.

  14. Detection of distant metastases in patients with locally advanced breast cancer: role of {sup 18}F-fluorodeoxyglucose positron emission tomography/computed tomography and conventional imaging with computed tomography scans

    Energy Technology Data Exchange (ETDEWEB)

    Bitencourt, Almir Galvao Vieira; Andrade, Wesley Pereira; Cunha, Rodrigo Rodrigues da; Conrado, Jorge Luis Fonseca de Acioli; Lima, Eduardo Nobrega Pereira; Barbosa, Paula Nicole Vieira Pinto; Chojniak, Rubens, E-mail: rodrigo.rcunha@hotmail.com [A. C. Camargo Cancer Center, Sao Paulo, SP (Brazil); Hospital Beneficincia Portuguesa de Sao Paulo, Sao Paulo, SP (Brazil)

    2017-07-15

    Objective: To evaluate positron emission tomography/computed tomography (PET/CT) and conventional imaging tests for the detection of distant metastases in patients with locally advanced breast cancer. Materials and Methods: We included 81 patients with breast cancer who had undergone {sup 18}-fluorodeoxyglucose (FDG) PET/CT before treatment. Conventional imaging included the following: bone scintigraphy; chest X-ray (in 14.5%) or CT (in 85.5%); and abdominal ultrasound (in 10.8%), CT (in 87.8%), or magnetic resonance imaging (in 1.4%). Histopathology and clinical/imaging follow-up served as reference. Results: Distant metastases were observed in nine patients (11.1%). On patient-based analysis, conventional imaging identified distant metastases in all 9 patients. In one patient, the initial {sup 18}F-FDG PET/CT failed to demonstrate bone metastases that was evident on bone scintigraphy. In two patients, the CT scan failed to show extra-axillary lymph node metastases that were identified on {sup 18}F-FDG PET/CT. There was no significant difference between {sup 18}F-FDG PET/CT and conventional imaging in terms of their sensitivity for the detection of distant metastases in patients with locally advanced breast cancer. Conclusion: This study showed that {sup 18}F-FDG PET/CT and conventional imaging with CT scans had similar sensitivity for the diagnosis of distant metastases in patients with locally advanced breast cancer. {sup 18}F-FDG PET/CT can add information about extra-axillary lymph node involvements. (author)

  15. Neuromyelitis optica: a diffusional kurtosis imaging study.

    Science.gov (United States)

    Doring, T M; Lopes, F C R; Kubo, T T A; Tukamoto, G; Kimura, M C; Strecker, R M; Domingues, R C; Gasparetto, E L

    2014-12-01

    Conventional MR imaging typically yields normal images of the brain or indicates lesions in areas of high aquaporin expression in patients with neuromyelitis optica. Diffusional kurtosis imaging was applied in patients with neuromyelitis optica to determine whether this technique could detect alterations in diffusion and diffusional kurtosis parameters in normal-appearing white matter and to explore the relationship between diffusional kurtosis imaging and DTI parameters. Thirteen patients with neuromyelitis optica and 13 healthy controls underwent MR imaging of the brain with conventional and diffusional kurtosis imaging sequences. Tract-based spatial statistics and region-of-interest-based analyses were conducted to identify differences between patients with neuromyelitis optica and controls through conventional DTI and diffusional kurtosis imaging parameters. The parameters were correlated to determine the potential relationship between them. Compared with healthy controls, several diffusional kurtosis imaging and DTI parameters were altered in various fiber tracts of patients with neuromyelitis optica (P optica. We found a negative correlation between diffusional kurtosis imaging (radial kurtosis, axial kurtosis, mean kurtosis) and the corresponding DTI parameters (radial diffusivity, axial diffusivity, mean diffusivity). Positive correlations were found for radial kurtosis and mean kurtosis with fractional anisotropy. This study demonstrated differences in conventional diffusion and diffusional kurtosis parameters, especially radial kurtosis, in the normal-appearing white matter of patients with neuromyelitis optica compared with healthy controls. Larger studies of patients with neuromyelitis optica should be performed to assess the potential clinical impact of these findings. © 2014 by American Journal of Neuroradiology.

  16. The functional relevance of diffusion tensor imaging in comparison to conventional MRI in patients with cervical compressive myelopathy

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Young-Mi; Oh, Jae-Keun; Song, Ji-Sun [Hallym University Sacred Heart Hospital, College of Medicine, Hallym University, Spine Center, Anyang-si, Gyeonggi-do (Korea, Republic of); Yoo, Woo-Kyoung [Hallym University Sacred Heart Hospital, College of Medicine, Hallym University, Department of Physical Medicine and Rehabilitation, Anyang-si (Korea, Republic of); Hallym University Sacred Heart Hospital, College of Medicine, Hallym University, Hallym Institute for Translational Genomics and Bioinformatics, Anyang-si (Korea, Republic of); Yoo, Je Hyun; Kwak, Yoon Hae [Hallym University Sacred Heart Hospital, College of Medicine, Hallym University, Department of Orthopaedic surgery, Anyang-si (Korea, Republic of); Kim, Seok Woo [Hallym University Sacred Heart Hospital, College of Medicine, Hallym University, Spine Center, Anyang-si, Gyeonggi-do (Korea, Republic of); Hallym University Sacred Heart Hospital, College of Medicine, Hallym University, Department of Orthopaedic surgery, Anyang-si (Korea, Republic of)

    2017-11-15

    To determine the functional relevance of diffusion tensor imaging (DTI) metrics and conventional MRI (signal intensity change in T2, compression ratio) by measuring the correlation of these parameters with clinical outcome measured by the modified Japanese Orthopedic Association (mJOA) score. A total of 20 cervical myelopathy (CM) patients participated in this prospective cohort study. The severities of CM were assessed using the mJOA score. Conventional MRIs (T2-weighted images) measuring the signal changes of spinal cords and the degree of compression at the lesion level and DTI metrics [fractional anisotropy (FA), apparent diffusion coefficient (ADC)] at each lesion and below each lesion (C7/T1) level were acquired using a 3-T Achieva MRI. These parameters were correlated with the mJOA scores to determine the functional relevance. Ninety percent of CM patients showed signal changes and 30 % of patients noted a more than 40% canal compression ratio in conventional MRIs at the lesion level; however, these findings were not correlated with the mJOA score (p < 0.05). In contrast, FA values on DTI showed high sensitivity to CM (100%), which was well correlated with the mJOA score (p = 0.034, r = 0.475) below the lesion level (C7/T1). This study showed a meaningful symptomatic correlation between mJOA scores and FA values below the lesion levels in CM patients. It could give us more understanding of the pathological changes in spinal cords matched with various clinical findings in CM patients than the results from conventional MRI. (orig.)

  17. Comparison of bladder neck position in nulliparous and parous women using MR images in the sitting position

    International Nuclear Information System (INIS)

    Masaki, Kiyoko; Okayama, Hisayo; Tuchikawa, Sachi; Saito, Yoshino; Endo, Yoshihiro; Morikawa, Shigehiro; Ninomiya, Sanae; Saito, Izumi; Hiraiwa, Yasuyuki

    2011-01-01

    The purpose of this study was to investigate the influence of childbirth on pelvic floor relaxation in females using the bladder neck position. The position of bladder neck was examined in 17 nulligravid (19-24 years of age) and 55 parous women (35-54) using MR images in the sitting position. The position of bladder neck from pubococcygeal line was 13.4 mm (mean) in nulligravid women, and 8.5 mm in parous women (p<0.05). The bladder neck position in parous women was significantly lower than that in nulligravid women. Therefore, it was clearly shown that childbirth causes the pelvic floor relaxation. (author)

  18. Digital hilar tomography. Comparison with conventional technique

    International Nuclear Information System (INIS)

    Schaefer, C.B.; Braunschweig, R.; Teufl, F.; Kaiser, W.; Claussen, C.D.

    1993-01-01

    The aim of the following study was to compare conventional hilar tomography and digital hilar tomography. 20 patients were examined both with conventional and digital hilar tomography using the same tomographic technique and the identical exposure dose. All patients underwent computed tomography of the chest as a golden standard. The digital technique, especially the edge-enhanced image version, showed superior image quality. ROC-analysis by 4 readers found equal diagnostic performance without any statistical difference. Digital hilar tomography shows a superior and constant image quality and lowers the rate of re-exposure. Therefore, digital hilar tomography is the preferable method. (orig.) [de

  19. Factors influencing fast low angle positive contrast steady-state free precession (FLAPS) magnetic resonance imaging

    International Nuclear Information System (INIS)

    Dharmakumar, Rohan; Koktzoglou, Ioannis; Li Debiao

    2007-01-01

    The presence of susceptibility-shifting media can lead to signal voids in magnetic resonance images. While signal voids have been traditionally used to detect such magnetic perturbers, selective magnetic resonance imaging of off-resonant spins surrounding susceptibility-shifted media allows for them to be visualized as hyper-intense (positive contrast) regions. These positive contrast methods can potentially improve the detection conspicuity of magnetic perturbers against regions that appear dark due to the absence of protons, such as air. Recently, a fast low angle positive contrast steady-state free precession (FLAPS) technique has been proposed as a positive contrast imaging method. This work systematically evaluates the contrast characteristics and acquisition strategies of FLAPS-based imaging from the standpoint of imaging parameters and physical properties of the magnetic perturbers. Results show that scan parameters (T R , flip angle, B 0 ), physical properties of the perturber (size and concentration of shift reagent) and the ratio of the relaxation constants (T 1 /T 2 ) of the medium are significant factors influencing the FLAPS-based positive contrast

  20. Rejecting conventional wisdom: how academic medical centers can regain their leadership positions.

    Science.gov (United States)

    Krauss, K; Smith, J

    1997-07-01

    Academic medical centers (i.e., medical schools and their principal hospitals) are following very similar strategies in attempts to secure their futures. It is likely that these undifferentiated strategies will fail, since most of them have been copied from the lower-cost, geographically better-positioned hospitals and health systems. Despite a wealth of innovative, entrepreneurial talent and the potential to reshape the world that AMCs live in, most AMCs are in reactive modes. Future directions and strategies are almost always shaped, forced, and justified by external pressures. The major problem with the strategic plans of most AMCs is that they are based on conventional industry wisdom. Strategic plans tend not to be analytically driven. The insight and understanding of those factors that drive the demand for AMCs' services and determine the performances of AMCs are lacking. The authors note some questions that are critical to the formulation of strategies for AMCs. For example, how can the research mission be changed from a cost-based to a value-based endeavor? Most AMCs cannot answer these questions, and if they do address them in the planning process, they do so superficially. Several examples of the factors that need to be understood are also given, such as patients' purposes and needs in seeking specialty care. Alternative strategies are listed, such as maintaining and exploiting the economic irrationality of the market rather than acting as if it were economically rational or forcing it to become so. Last, the authors outline the scope of the changes that are required and urge AMCs to reject conventional wisdom, determine their own unique situations, and work from there.

  1. Comparative study between computed radiography and conventional radiography

    International Nuclear Information System (INIS)

    Noorhazleena Azaman; Khairul Anuar Mohd Salleh; Sapizah Rahim; Shaharudin Sayuti; Arshad Yassin; Abdul Razak Hamzah

    2010-01-01

    In Industrial Radiography, there are many criteria that need to be considered based on established standards to accept or reject the radiographic film. For conventional radiography, we need to consider the optical density by using the densitometer when viewing the film on the viewer. But in the computed radiography (CR) we need to evaluate and performed the analysis from the quality of the digital image through grey value. There are many factors that affected the digital image quality. One of the factors which are affected to the digital image quality in the image processing is grey value that related to the contrast resolution. In this work, we performed grey value study measurement on digital radiography systems and compared it with exposed films in conventional radiography. The test sample is a steel step wedge. We found out the contrast resolution is higher in Computed Radiography compared with Conventional Radiography. (author)

  2. New approach to imaging HIV-positive patients with pyrexia of undetermined origin

    International Nuclear Information System (INIS)

    Buscombe, J.; Miller, R.; Lui, D.; Ell, P.J.

    1990-01-01

    This paper established if imaging with Tc-99m human immunoglobulin (HIG) in addition to Ga-67 citrate increased the diagnostic sensitivity in patients who have pyrexia of unknown origin (PUO) and who have tested positive for human immunodeficiency virus (HIV). The authors studied 18 HIV-positive patients with PUO for 3 or more weeks. Imaging was performed 4 and 20 hours after administration of 200 MBq of Tc-99m HIG and 24, 48, and (if indicated) 72 hours after administration of 300 MBq of Ga-67. Anterior whole body and relevant spot view were obtained for both agents. Twenty-four sites of infection were confirmed microbiologically in 12 patients. Ga-67 scan results were positive in 22 of these sites, and Tc-99m HIG results were positive in 13; the nine Ga-positive sites that were Tc-negative were intrathoracic (one Pneumocystis carinii, eight Mycobacterium intracellulare)

  3. Comment on ``Perfect imaging with positive refraction in three dimensions''

    Science.gov (United States)

    Merlin, R.

    2010-11-01

    Leonhardt and Philbin [Phys. Rev. APLRAAN1050-294710.1103/PhysRevA.81.011804 81, 011804(R) (2010)] have recently constructed a mathematical proof that the Maxwell's fish-eye lens provides perfect imaging of electromagnetic waves without negative refraction. In this comment, we argue that the unlimited resolution is an artifact of having introduced an unphysical drain at the position of the geometrical image. The correct solution gives focusing consistent with the standard diffraction limit.

  4. INDOOR POSITIONING AND NAVIGATION BASED ON CONTROL SPHERECAL PANORAMIC IMAGES

    Directory of Open Access Journals (Sweden)

    T.-C. Huang

    2016-06-01

    Full Text Available Continuous indoor and outdoor positioning and navigation is the goal to achieve in the field of mobile mapping technology. However, accuracy of positioning and navigation will be largely degraded in indoor or occluded areas, due to receiving weak or less GNSS signals. Targeting the need of high accuracy indoor and outdoor positioning and navigation for mobile mapping applications, the objective of this study is to develop a novel method of indoor positioning and navigation with the use of spherical panoramic image (SPI. Two steps are planned in the technology roadmap. First, establishing a control SPI database that contains a good number of well-distributed control SPIs pre-acquired in the target space. A control SPI means an SPI with known exterior orientation parameters, which can be solved with a network bundle adjustment of SPIs. Having a control SPI database, the target space will be ready to provide the service of positioning and navigation. Secondly, the position and orientation of a newly taken SPI can be solved by using overlapped SPIs searched from the control SPI database. The method of matching SPIs and finding conjugate image features will be developed and tested. Two experiments will be planned and conducted in this paper to test the feasibility and validate the test results of the proposed methods. Analysis of appropriate number and distribution of needed control SPIs will also be included in the experiments with respect to different test cases.

  5. Peritendinous calcinosis of calcaneus tendon associated with dermatomyositis: correlation between conventional radiograph, ultrasound, magnetic resonance imaging and gross surgical pathology

    International Nuclear Information System (INIS)

    Rosa, Ana Claudia Ferreira; Gomide, Lidyane Marques de Paula; Lemes, Marcella Stival

    2006-01-01

    Interstitial calcinosis is an uncommon condition in which there is either localized or widely disseminated deposition of calcium in the skin, subcutaneous tissues, muscles, and tendons. Calcinosis is often associated with collagen diseases, scleroderma and dermatomyositis. The authors report a case of interstitial calcinosis associated with dermatomyositis studied with conventional radiograph, ultrasound and magnetic resonance imaging, and correlate the imaging findings with the results of surgical pathology gross examination. (author)

  6. Consumer opinion on social policy approaches to promoting positive body image: Airbrushed media images and disclaimer labels.

    Science.gov (United States)

    Paraskeva, Nicole; Lewis-Smith, Helena; Diedrichs, Phillippa C

    2017-02-01

    Disclaimer labels on airbrushed media images have generated political attention and advocacy as a social policy approach to promoting positive body image. Experimental research suggests that labelling is ineffective and consumers' viewpoints have been overlooked. A mixed-method study explored British consumers' ( N = 1555, aged 11-78 years) opinions on body image and social policy approaches. Thematic analysis indicated scepticism about the effectiveness of labelling images. Quantitatively, adults, although not adolescents, reported that labelling was unlikely to improve body image. Appearance diversity in media and reorienting social norms from appearance to function and health were perceived as effective strategies. Social policy and research implications are discussed.

  7. Reduction of false-positive recalls using a computerized mammographic image feature analysis scheme

    Science.gov (United States)

    Tan, Maxine; Pu, Jiantao; Zheng, Bin

    2014-08-01

    The high false-positive recall rate is one of the major dilemmas that significantly reduce the efficacy of screening mammography, which harms a large fraction of women and increases healthcare cost. This study aims to investigate the feasibility of helping reduce false-positive recalls by developing a new computer-aided diagnosis (CAD) scheme based on the analysis of global mammographic texture and density features computed from four-view images. Our database includes full-field digital mammography (FFDM) images acquired from 1052 recalled women (669 positive for cancer and 383 benign). Each case has four images: two craniocaudal (CC) and two mediolateral oblique (MLO) views. Our CAD scheme first computed global texture features related to the mammographic density distribution on the segmented breast regions of four images. Second, the computed features were given to two artificial neural network (ANN) classifiers that were separately trained and tested in a ten-fold cross-validation scheme on CC and MLO view images, respectively. Finally, two ANN classification scores were combined using a new adaptive scoring fusion method that automatically determined the optimal weights to assign to both views. CAD performance was tested using the area under a receiver operating characteristic curve (AUC). The AUC = 0.793  ±  0.026 was obtained for this four-view CAD scheme, which was significantly higher at the 5% significance level than the AUCs achieved when using only CC (p = 0.025) or MLO (p = 0.0004) view images, respectively. This study demonstrates that a quantitative assessment of global mammographic image texture and density features could provide useful and/or supplementary information to classify between malignant and benign cases among the recalled cases, which may eventually help reduce the false-positive recall rate in screening mammography.

  8. VLC-based indoor location awareness using LED light and image sensors

    Science.gov (United States)

    Lee, Seok-Ju; Yoo, Jong-Ho; Jung, Sung-Yoon

    2012-11-01

    Recently, indoor LED lighting can be considered for constructing green infra with energy saving and additionally providing LED-IT convergence services such as visible light communication (VLC) based location awareness and navigation services. For example, in case of large complex shopping mall, location awareness to navigate the destination is very important issue. However, the conventional navigation using GPS is not working indoors. Alternative location service based on WLAN has a problem that the position accuracy is low. For example, it is difficult to estimate the height exactly. If the position error of the height is greater than the height between floors, it may cause big problem. Therefore, conventional navigation is inappropriate for indoor navigation. Alternative possible solution for indoor navigation is VLC based location awareness scheme. Because indoor LED infra will be definitely equipped for providing lighting functionality, indoor LED lighting has a possibility to provide relatively high accuracy of position estimation combined with VLC technology. In this paper, we provide a new VLC based positioning system using visible LED lights and image sensors. Our system uses location of image sensor lens and location of reception plane. By using more than two image sensor, we can determine transmitter position less than 1m position error. Through simulation, we verify the validity of the proposed VLC based new positioning system using visible LED light and image sensors.

  9. Comparison of conventional color fundus photography and multicolor imaging in choroidal or retinal lesions.

    Science.gov (United States)

    Muftuoglu, Ilkay Kilic; Gaber, Raouf; Bartsch, Dirk-Uwe; Meshi, Amit; Goldbaum, Michael; Freeman, William R

    2018-04-01

    Our purpose was to compare the characteristics of the retinal and choroidal lesions including choroidal nevus, choroidal melanoma and congenital hypertrophy of the retina pigment epithelium using conventional color fundus photography (CFP) and multicolor imaging (MCI). The paired images of patients with retinal or choroidal lesions were assessed for the visibility of lesion's border, halo and drusen using a grading scale (0-2). The area of the lesion was measured on both imaging modalities. The same grading was also done on the individual color channels of MCI for a further evaluation. Thirty-three eyes of 33 patients were included. There were no significant differences in the mean border, drusen and halo visibility scores between the two imaging modalities (p = 0.12, p = 0.70, p = 0.35). However, the mean area of the lesion was significantly smaller on MCI than that on CFP (14.9±3.3 versus 18.7±3.4 mm 2 , p = 0.01). The appearance of choroidal and/ or retinal lesions on MCI may be different than that on CFP. Though MCI can provide similar information with CFP for the features of retinal and/ or choroidal lesions including border, halo and drusen; the infrared light reflection on MCI underestimates the extent of the choroidal lesion by 33%.

  10. Perfusion magnetic resonance imaging and magnetic resonance spectroscopy of cerebral gliomas showing imperceptible contrast enhancement on conventional magnetic resonance imaging

    International Nuclear Information System (INIS)

    Batra, A.; Tripathi, R.P.; Singh, A.K.

    2004-01-01

    The purpose of the present paper was to evaluate the utility of perfusion MRI in cerebral gliomas showing imperceptible contrast enhancement on conventional MRI, and to evaluate the relationships of perfusion MRI and magnetic resonance (MR) spectroscopic results in these tumours. Twenty-two patients with histopathologically proven cerebral gliomas and showing insignificant contrast enhancement on conventional MR were included in the present study. All patients underwent perfusion MRI and MR spectroscopy on a 1.5-T MR system. Significant differences of the relative cerebral blood volume (rCBV) values and the choline : creatine ratios were noted between low-grade and anaplastic gliomas (P < 0.01). Good correlation was found between the rCBV values and the choline : creatine values (y = 0. 532x + 1.5643; r = 0.67). Perfusion MRI can be a useful tool in assessing the histopathological grade of non-contrast-enhancing cerebral gliomas. Along with MR spectroscopic imaging it can serve as an important technique for preoperative characterization of such gliomas, so that accurate targeting by stereotactic biopsies is possible. Copyright (2004) Blackwell Science Pty Ltd

  11. Problems of fluorescent imaging and its solution using nanofluorophores. Part I: Advantages of fluorescent nanoparticles over conventional organic fluorophores

    International Nuclear Information System (INIS)

    Zhelev, Z.; Hadjidekov, G.; Zlateva, G.; Spasov, L.; Bakalova, R.

    2011-01-01

    The application of fluorescence in deep-tissue imaging is rapidly expanding in fast several years. The progress in fluorescent molecular probes and fluorescent imaging techniques gives an opportunity to detect single cells and even molecules in live organisms. The highly sensitive and high-speed fluorescent molecular sensors and detection devices allow the application of fluorescence in functional imaging. With development of novel bright fluorophores based on nano-technologies and fluorescence scanners with high spatial and temporal resolution, the fluorescent imaging has a potential to become an alternative of the other non-invasive imaging techniques as magnetic resonance imaging, positron-emission tomography, X-ray, computing tomography. This review outlines the current status and future trends of fluorescent nanoparticles - quantum dots (QDs), as a new generation of fluorophores in experimental and pre-clinical fluorescent imaging diagnostic. Part 1 focuses on the advantages of quantum dots over conventional organic fluorophores and defines the major requirements to the 'perfect' fluorophore for fluorescent deep-tissue imaging diagnostic. The analysis is based on the limitations of fluorescent imaging in vivo and overcome by using quantum dots

  12. Eye dose measurements using conventional and rare-earth screens during tomography of the para-nasal sinuses

    International Nuclear Information System (INIS)

    Eddleston, B.; Moores, B.M.; Walker, A.

    1977-01-01

    Eye dose measurements have been performed when using medium speed conventional and rare-earth screen-film combinations during tomography of the para-nasal sinuses. The measurements showed that using conventional intensifying screens with the A.P. view a total eye dose of about 20 rad may be given during an examination. This eye dose can be reduced by 98% using the P.A. position. If rare-earth screen/film combinations were employed the eye dose measured in the A.P. view was reduced by 75% of that obtained with conventional screens without detectable loss of image quality. A total eye dose reduction of about 99.5% was measured in the P.A. view with the rare-earth systems. (author)

  13. Waif goodbye! Average-size female models promote positive body image and appeal to consumers.

    Science.gov (United States)

    Diedrichs, Phillippa C; Lee, Christina

    2011-10-01

    Despite consensus that exposure to media images of thin fashion models is associated with poor body image and disordered eating behaviours, few attempts have been made to enact change in the media. This study sought to investigate an effective alternative to current media imagery, by exploring the advertising effectiveness of average-size female fashion models, and their impact on the body image of both women and men. A sample of 171 women and 120 men were assigned to one of three advertisement conditions: no models, thin models and average-size models. Women and men rated average-size models as equally effective in advertisements as thin and no models. For women with average and high levels of internalisation of cultural beauty ideals, exposure to average-size female models was associated with a significantly more positive body image state in comparison to exposure to thin models and no models. For men reporting high levels of internalisation, exposure to average-size models was also associated with a more positive body image state in comparison to viewing thin models. These findings suggest that average-size female models can promote positive body image and appeal to consumers.

  14. Evaluation of Image-Guided Positioning for Frameless Intracranial Radiosurgery

    International Nuclear Information System (INIS)

    Lamba, Michael; Breneman, John C.; Warnick, Ronald E.

    2009-01-01

    Purpose: The standard for target alignment and immobilization in intracranial radiosurgery is frame-based alignment and rigid immobilization using a stereotactic head ring. Recent improvements in image-guidance systems have introduced the possibility of image-guided radiosurgery with nonrigid immobilization. We present data on the alignment accuracy and patient stability of a frameless image-guided system. Methods and Materials: Isocenter alignment errors were measured for in vitro studies in an anthropomorphic phantom for both frame-based stereotactic and frameless image-guided alignment. Subsequently, in vivo studies assessed differences between frame-based and image-guided alignment in patients who underwent frame-based intracranial radiosurgery. Finally, intratreatment target stability was determined by image-guided alignment performed before and after image-guided mask immobilized radiosurgery. Results: In vitro hidden target localization errors were comparable for the framed (0.7 ± 0.5 mm) and image-guided (0.6 ± 0.2 mm) techniques. The in vivo differences in alignment were 0.9 ± 0.5 mm (anteroposterior), -0.2 ± 0.4 mm (superoinferior), and 0.3 ± 0.5 mm (lateral). For in vivo stability tests, the mean distance differed between the pre- and post-treatment positions with mask-immobilized radiosurgery by 0.5 ± 0.3 mm. Conclusion: Frame-based and image-guided alignment accuracy in vitro was comparable for the system tested. In vivo tests showed a consistent trend in the difference of alignment in the anteroposterior direction, possibly due to torque to the ring and mounting system with frame-based localization. The mask system as used appeared adequate for patient immobilization.

  15. The effect of image position on the Independent Components of natural binocular images.

    Science.gov (United States)

    Hunter, David W; Hibbard, Paul B

    2018-01-11

    Human visual performance degrades substantially as the angular distance from the fovea increases. This decrease in performance is found for both binocular and monocular vision. Although analysis of the statistics of natural images has provided significant insights into human visual processing, little research has focused on the statistical content of binocular images at eccentric angles. We applied Independent Component Analysis to rectangular image patches cut from locations within binocular images corresponding to different degrees of eccentricity. The distribution of components learned from the varying locations was examined to determine how these distributions varied across eccentricity. We found a general trend towards a broader spread of horizontal and vertical position disparity tunings in eccentric regions compared to the fovea, with the horizontal spread more pronounced than the vertical spread. Eccentric locations above the centroid show a strong bias towards far-tuned components, eccentric locations below the centroid show a strong bias towards near-tuned components. These distributions exhibit substantial similarities with physiological measurements in V1, however in common with previous research we also observe important differences, in particular distributions of binocular phase disparity which do not match physiology.

  16. Molecular Morphology of Pituitary Cells, from Conventional Immunohistochemistry to Fluorescein Imaging

    Directory of Open Access Journals (Sweden)

    R. Yoshiyuki Osamura

    2011-04-01

    Full Text Available In situ hybridization (ISH at the electron microscopic (EM level is essential for elucidating the intracellular distribution and role of mRNA in protein synthesis. EM-ISH is considered to be an important tool for clarifying the intracellular localization of mRNA and the exact site of pituitary hormone synthesis on the rough endoplasmic reticulum. A combined ISH and immunohistochemistry (IHC under EM (EM-ISH&IHC approach has sufficient ultrastructural resolution, and provides two-dimensional images of the subcellular localization of pituitary hormone and its mRNA in a pituitary cell. The advantages of semiconductor nanocrystals (quantum dots, Qdots and confocal laser scanning microscopy (CLSM enable us to obtain three-dimensional images of the subcellular localization of pituitary hormone and its mRNA. Both EM-ISH&IHC and ISH & IHC using Qdots and CLSM are useful for understanding the relationships between protein and mRNA simultaneously in two or three dimensions. CLSM observation of rab3B and SNARE proteins such as SNAP-25 and syntaxin has revealed that both rab3B and SNARE system proteins play important roles and work together as the exocytotic machinery in anterior pituitary cells. Another important issue is the intracellular transport and secretion of pituitary hormone. We have developed an experimental pituitary cell line, GH3 cell, which has growth hormone (GH linked to enhanced yellow fluorescein protein (EYFP. This stable GH3 cell secretes GH linked to EYFP upon stimulation by Ca2+ influx or Ca2+ release from storage. This GH3 cell line is useful for the real-time visualization of the intracellular transport and secretion of GH. These three methods from conventional immunohistochemistry and fluorescein imaging allow us to consecutively visualize the process of transcription, translation, transport and secretion of anterior pituitary hormone.

  17. Magnetic resonance dacryocystography: comparison between conventional surface coils and microscopic coils

    International Nuclear Information System (INIS)

    Abreu Junior, Luiz de; Wolosker, Angela Maria Borri; Borri, Maria Lucia; Galvao Filho, Mario de Melo; Hartmann, Luiz Guilherme de Carvalho; D'Ippolito, Giuseppe; Castro, Claudio Campi de

    2008-01-01

    Objective: Magnetic resonance imaging has been utilized in the evaluation of the lacrimal apparatus with some advantages over conventional dacryocystography. The present study was aimed at acquiring high resolution images utilizing microscopic coils for evaluating typical structures of the lacrimal apparatus as compared with the findings observed with conventional surface coils. Materials and methods: Five asymptomatic volunteers with no history of epiphora were submitted to high-field magnetic resonance imaging with microscopic and conventional surface coils, and STIR sequence after instillation of saline solution. The definition of normal anatomic structures of lacrimal apparatuses was compared utilizing conventional and microscopic surface coils. Based on a consensual scoring system, the mean values for each structure were calculated by two observers. Results: In 90% of cases, higher scores were attributed to images acquired with the microscopic coil. On average, a 1.17 point increase was observed in the scoring of anatomic structures imaged with the microscopic coil. Additionally, a subjective improvement was observed in the signal-to-noise ratio with the microscopic coil. Conclusion: Magnetic resonance dacryocystography with microscopic coils is the appropriate method for evaluating the lacrimal apparatus, providing images with better quality as compared with those acquired with conventional surface coils. (author)

  18. The Formation of a Positive International Image of Country as a Means of Enhancing Competitiveness

    Directory of Open Access Journals (Sweden)

    Novikova Ludmyla V.

    2017-11-01

    Full Text Available The article is aimed at studying the essence of the concept of «image of the state» and substantiating the conceptual model of forming a positive international image of country as a means of enhancing competitiveness in the international market. The essence of the concept of «image of the State» has been defined. The factors influencing the formation of the international image of country have been distributed and systematized. The principles on which the process of formation of country image of modern format, receiving public recognition and adequate international estimation, have been allocated. A conceptual model of formation of positive international image of country, based on the hypothesis of influence of positive image on creation of significant competitive advantages in the international market of goods and services, has been proposed. The key features of the model are defined as: clear distribution of the roles of the stakeholders of national image – subjects of the global economic system, level of their involvement in the process of formation and integration of the State economy into the system of international institutions.

  19. Image quality in conventional film screen system, digital phosphor storage plate mammography in magnification technique and digital mammography in CCD-technique

    International Nuclear Information System (INIS)

    Schulz-Wendtland, R.; Aichinger, U.; Boehner, C.; Dobritz, M.; Bautz, W.; Saebel, M.

    2000-01-01

    Purpose: Comparison of image quality between conventional film screen system, digital phosphor storage plate mammography in magnification technique and digital mammography in CCD-technique. Materials and Methods: Radiograms of a RMI-mammography phantom were acquired using a conventional film screen system, two digital storage plate systems and two digital systems in CCD-technique. Additionally, the radiograms of one digital phosphor storage plate system were post-processed emphasizing contrast and included in the comparison. Results: The detectability of details was the best with the digital mammography in CCD-technique in comparison with the conventional film screen technique resp. digital phosphor storage plate in magnification technique. Conclusions: Based on these results there is the possibility to replace the conventional film screen system by further studies - this has to be confirmed. (orig.) [de

  20. The value of adding conventional MR imaging to MR cholangiopancreatography in differentiation of benign and malignant causes of postoperative disorders

    International Nuclear Information System (INIS)

    Sun Changjin; Zhou Xiangping; Song Bin; Chen Xian; Liu Rongbo; Yan Zhihan; Xiong Yan

    2003-01-01

    Objective: To determine the value of conventional T 1 - and T 2 -weighted images and gadolinium-enhanced magnetic resonance (MR) images as a supplement to MR cholangiopancreatography (MRCP) in differentiation of benign from malignant causes of postoperative disorders in the biliary ductal system. Methods: Sixty-one patients with postoperative disorders in the biliary ductal system with proved causes underwent MRCP, conventional T 1 - and less heavily T 2 -weighted images, as well as gadolinium-enhanced images. Two radiologists independently reviewed MRCP images alone, MRCP plus nonenhanced T 1 - and T 2 -weighted images, and MRCP plus nonenhanced and gadolinium-enhanced images. The results of MR findings were compared with that of the surgical findings and the pathology. Results: For the diagnosis of postoperative disorders only with MRCP images, the sensitivity, specificity, and accuracy was 42.1%, 80.9% and 68.9% for radiologist 1 and 47.4%, 85.7%, and 73.8% for radiologist 2, respectively. When MRCP images were interpreted with T 1 - and T 2 -weighted images, the sensitivity, specificity, and accuracy was 78.9%, 92.9% and 88.5% for radiologist 1 and, 78.9%, 95.2%, and 90.2% for radiologist 2, respectively. When MRCP images were combined with both nonenhanced T 1 - and T 2 -weighted images and enhanced MR images, the sensitivity, specificity, and accuracy was 84.2%, 95.2% and 91.8% for radiologist 1 and 84.2%, 97.6%, and 93.4% for radiologist 2, respectively. There was no significant difference between the 2 readers (P>0.05). For differentiation of benign from malignant causes of postoperative disorders, the area under the receiver operating characteristic curve (Az) was significantly larger for MRCP images interpreted with T 1 - and T 2 weighted images (0.907 for reader 1, 0.920 for reader 2) than for MRCP images alone (0.682 reader 1, 0.714 for reader 2) (P 1 - and T 2 -weighted images did not significantly increase the accuracy (Az = 0.948 for reader 1, 0

  1. SU-F-T-469: A Clinically Observed Discrepancy Between Image-Based and Log- Based MLC Position

    Energy Technology Data Exchange (ETDEWEB)

    Neal, B; Ahmed, M; Siebers, J [University of Virginia Health System, Charlottesville, VA (United States)

    2016-06-15

    Purpose: To present a clinical case which challenges the base assumption of log-file based QA, by showing that the actual position of a MLC leaf can suddenly deviate from its programmed and logged position by >1 mm as observed with real-time imaging. Methods: An EPID-based exit-fluence dosimetry system designed to prevent gross delivery errors was used in cine mode to capture portal images during treatment. Visual monitoring identified an anomalous MLC leaf pair gap not otherwise detected by the automatic position verification. The position of the erred leaf was measured on EPID images and log files were analyzed for the treatment in question, the prior day’s treatment, and for daily MLC test patterns acquired on those treatment days. Additional standard test patterns were used to quantify the leaf position. Results: Whereas the log file reported no difference between planned and recorded positions, image-based measurements showed the leaf to be 1.3±0.1 mm medial from the planned position. This offset was confirmed with the test pattern irradiations. Conclusion: It has been clinically observed that log-file derived leaf positions can differ from their actual positions by >1 mm, and therefore cannot be considered to be the actual leaf positions. This cautions the use of log-based methods for MLC or patient quality assurance without independent confirmation of log integrity. Frequent verification of MLC positions through independent means is a necessary precondition to trusting log file records. Intra-treatment EPID imaging provides a method to capture departures from MLC planned positions. Work was supported in part by Varian Medical Systems.

  2. Verification of multileaf collimator leaf positions using an electronic portal imaging device

    International Nuclear Information System (INIS)

    Samant, Sanjiv S.; Zheng Wei; Parra, Nestor Andres; Chandler, Jason; Gopal, Arun; Wu Jian; Jain Jinesh; Zhu Yunping; Sontag, Marc

    2002-01-01

    An automated method is presented for determining individual leaf positions of the Siemens dual focus multileaf collimator (MLC) using the Siemens BEAMVIEW(PLUS) electronic portal imaging device (EPID). Leaf positions are computed with an error of 0.6 mm at one standard deviation (σ) using separate computations of pixel dimensions, image distortion, and radiation center. The pixel dimensions are calculated by superimposing the film image of a graticule with the corresponding EPID image. A spatial correction is used to compensate for the optical distortions of the EPID, reducing the mean distortion from 3.5 pixels (uncorrected) per localized x-ray marker to 2 pixels (1 mm) for a rigid rotation and 1 pixel for a third degree polynomial warp. A correction for a nonuniform dosimetric response across the field of view of the EPID images is not necessary due to the sharp intensity gradients across leaf edges. The radiation center, calculated from the average of the geometric centers of a square field at 0 deg. and 180 deg. collimator angles, is independent of graticule placement error. Its measured location on the EPID image was stable to within 1 pixel based on 3 weeks of repeated extensions/retractions of the EPID. The MLC leaf positions determined from the EPID images agreed to within a pixel of the corresponding values measured using film and ionization chamber. Several edge detection algorithms were tested: contour, Sobel, Roberts, Prewitt, Laplace, morphological, and Canny. These agreed with each other to within ≤1.2 pixels for the in-air EPID images. Using a test pattern, individual MLC leaves were found to be typically within 1 mm of the corresponding record-and-verify values, with a maximum difference of 1.8 mm, and standard deviations of <0.3 mm in the daily reproducibility. This method presents a fast, automatic, and accurate alternative to using film or a light field for the verification and calibration of the MLC

  3. Patient radiation dose in conventional and xerographic cephalography

    International Nuclear Information System (INIS)

    Copley, R.L.; Glaze, S.A.; Bushong, S.C.; West, D.C.

    1979-01-01

    A comparison of the radiation doses for xeroradiographic and conventional film screen cephalography was made. Alderson tissue-equivalent phantoms were used for patient simulation. An optimum technique in terms of patient dose and image quality indicated that the dose for the Xerox process ranged from five to eleven times greater than that for the conventional process for entrance and exit exposures, respectively. This dose, however, falls within an acceptable range for other dental and medical radiation doses. It is recommended that conventional cephalography be used for routine purposes and that xeroradiography be reserved for situations requiring the increased image quality that the process affords

  4. The use of a portable gamma camera for preoperative lymphatic mapping: a comparison with a conventional gamma camera

    Energy Technology Data Exchange (ETDEWEB)

    Vidal-Sicart, Sergi; Paredes, Pilar [Hospital Clinic Barcelona, Nuclear Medicine Department (CDIC), Barcelona (Spain); Institut d' Investigacio Biomedica Agusti Pi Sunyer (IDIBAPS), Barcelona (Spain); Vermeeren, Lenka; Valdes-Olmos, Renato A. [Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital (NKI-AVL), Nuclear Medicine Department, Amsterdam (Netherlands); Sola, Oriol [Hospital Clinic Barcelona, Nuclear Medicine Department (CDIC), Barcelona (Spain)

    2011-04-15

    Planar lymphoscintigraphy is routinely used for preoperative sentinel node visualization, but large gamma cameras are not always available. We evaluated the reproducibility of lymphatic mapping with a smaller and portable gamma camera. In two centres, 52 patients with breast cancer received preoperative lymphoscintigraphy with a conventional gamma camera with a field of view of 40 x 40 cm. Static anterior and lateral images were performed at 15 min, 2 h and 4 h after injection of the radiotracer ({sup 99m}Tc-nanocolloid). At 2 h after injection, anterior and oblique images were also performed with a portable gamma camera (Sentinella, Oncovision) positioned to obtain a field of view of 20 x 20 cm. Visualization of lymphatic drainage on conventional images and images with the portable device were compared for number of nodes depicted, their intensity and localization of sentinel nodes. The images performed with the conventional gamma camera depicted sentinel nodes in 94%, while the portable gamma camera showed drainage in 73%. There was however no significant difference in visualization between the two devices when a lead shield was used to mask the injection area in 43 patients (95 vs 88%, p = 0.25). Second-echelon nodes were visualized in 62% of the patients with the conventional gamma camera and in 29% of the cases with the portable gamma camera. Preoperative imaging with a portable gamma camera fitted with a pinhole collimator to obtain a field of view of 20 x 20 cm is able to depict sentinel nodes in 88% of the cases, if a lead shield is used to mask the injection site. This device may be useful in centres without the possibility to perform a preoperative image. (orig.)

  5. The use of a portable gamma camera for preoperative lymphatic mapping: a comparison with a conventional gamma camera

    International Nuclear Information System (INIS)

    Vidal-Sicart, Sergi; Paredes, Pilar; Vermeeren, Lenka; Valdes-Olmos, Renato A.; Sola, Oriol

    2011-01-01

    Planar lymphoscintigraphy is routinely used for preoperative sentinel node visualization, but large gamma cameras are not always available. We evaluated the reproducibility of lymphatic mapping with a smaller and portable gamma camera. In two centres, 52 patients with breast cancer received preoperative lymphoscintigraphy with a conventional gamma camera with a field of view of 40 x 40 cm. Static anterior and lateral images were performed at 15 min, 2 h and 4 h after injection of the radiotracer ( 99m Tc-nanocolloid). At 2 h after injection, anterior and oblique images were also performed with a portable gamma camera (Sentinella, Oncovision) positioned to obtain a field of view of 20 x 20 cm. Visualization of lymphatic drainage on conventional images and images with the portable device were compared for number of nodes depicted, their intensity and localization of sentinel nodes. The images performed with the conventional gamma camera depicted sentinel nodes in 94%, while the portable gamma camera showed drainage in 73%. There was however no significant difference in visualization between the two devices when a lead shield was used to mask the injection area in 43 patients (95 vs 88%, p = 0.25). Second-echelon nodes were visualized in 62% of the patients with the conventional gamma camera and in 29% of the cases with the portable gamma camera. Preoperative imaging with a portable gamma camera fitted with a pinhole collimator to obtain a field of view of 20 x 20 cm is able to depict sentinel nodes in 88% of the cases, if a lead shield is used to mask the injection site. This device may be useful in centres without the possibility to perform a preoperative image. (orig.)

  6. Low tube voltage computed tomography urography using low-concentration contrast media: Comparison of image quality in conventional computed tomography urography.

    Science.gov (United States)

    Hwang, Inpyeong; Cho, Jeong Yeon; Kim, Sang Youn; Oh, Seung-June; Ku, Ja Hyeon; Lee, Joongyup; Kim, Seung Hyup

    2015-12-01

    The aim of the present study was to investigate the feasibility and image quality of excretory CT urography performed using low iodine-concentration contrast media and low tube voltage. This prospective study enrolled 63 patients who undergoing CT urography. The subjects were randomized into two groups of an excretory phase CT urography protocol and received either 240 mg I/mL of contrast media and 80 kVp of tube voltage (low-concentration protocol, n=32) or 350 mg I/mL and 120 kVp (conventional protocol, n=31). Two readers qualitatively evaluated images for sharpness of the urinary tract, image noise, streak artifact and overall diagnostic acceptability. The mean attenuation, signal-to-noise ratio, contrast-to-noise ratio and figure of merit were measured in the urinary tract. The non-inferiority test assessed the diagnostic acceptability between the two protocol groups. The low-concentration protocol showed a significantly lower effective radiation dose (3.44 vs. 5.70 mSv, Pcontrast-to-noise ratio and figure of merit were significantly higher in the low-concentration protocol along the entire urinary tract (Pcontrast media, 80 kVp tube voltage and an iterative reconstruction algorithm is beneficial to reduce radiation dose and iodine load, and its objective image quality and subjective diagnostic acceptability is not inferior to that of conventional CT urography. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  7. Application of fast spin-echo T2-weighted imaging for examination of the neurocranium. Comparison with the conventional T2-weighted spin-echo sequence

    International Nuclear Information System (INIS)

    Siewert, C.; Hosten, N.; Felix, R.

    1994-01-01

    T 2 -weighted spin-echo imaging is the standard screening procedure in MR imaging of the neutrocranium. We evaluated fast spin-echo T 2 -weighted imaging (TT 2 ) of the neurocranium in comparison to conventional spin-echo T 2 -weighted imaging (T 2 ). Signal-to-noise and contrast-to-noise ratio of normal brain tissues (basal ganglia, grey and white matter, CSF fluid) and different pathologies were calculated. Signal-to-noise ratio and contrast-to-noise ratio were significantly higher than TT 2 than in T 2 (with the exception of grey-to-white matter contrast). Tissues with increased content of water protons (mobile protons) showed the highest contrast to surrounding tissues. The increased signal intensity of fat must be given due attention in fatty lesions. Because the contrast-to-noise ratio between white matter and basal ganglia is less in TT 2 , Parkinson patients have to be examined by conventional T 2 . If these limitations are taken into account, fast spin-echo T 2 -weighted imaging is well appropriate for MR imaging of the neurocranium, resulting in heavy T 2 -weighting achieved in a short acquisition time. (orig.) [de

  8. Comparison of the image quality between volumetric and conventional high-resolution CT with 64-slice row CT

    International Nuclear Information System (INIS)

    Gao Yanli; Zhang Lei; Zhao Xia; Ma Min; Zhai Renyou

    2008-01-01

    Objective: To compare the image quality between volumetric high-resolution CT (VHRCT) and conventional high-resolution CT (CHRCT), and investigate the feasibility of VHRCT. Methods: Catphan 412 phantom was scanned with protocols of CHRCT and VHRCT on a set of GE Lightspeed VCT. The spatial-resolution (LP/cm), noise (standard deviation in an ROI) and radiation close (CTDI) were recorded for each CT scan. Difference of noise between CHRCT and VHRCT were evaluated by paired t test. In clinical study, 32 patients were scanned with VHRCT and CHRCT protocols. The image quality of CHRCT and VHRCT was rated and compared. The quality difference between CHRCT and VHRCT was assessed by Wilcoxon paired signed rank sum test. Results: In phantom study, the in-plane spatial-resolution of both VHRCT and CHRCT was 11 LP/cm for axial images and 12 LP/cm for coronal reformatted images. The noise of VHRCT and CHRCT was (69.18±2.77)HU and (54.62±2.12) HU respectively (t=-15.929, P 0.05). The quality assessment scores of VHRCT coronal reformatted images and CHRCT coronal reformatted images were 3.05 and 1.88 respectively with significant difference (Z= -5.088, P<0.01). Conclusion: The image quality of VHRCT cross-sectional image is similar to that of CHRCT. Multiplanar images with high resolution of VHRCT are recommended. The radiation dose of VHRCT remains to be optimized. (authors)

  9. Digital subtraction cerebral angiography by intraarterial injection: comparison with conventional angiography

    International Nuclear Information System (INIS)

    Brant-Zawadzki, M.; Gould, R.; Norman, D.; Newton, T.H.; Lane, B.

    1983-01-01

    For 4 months, a prototype digital subtraction system was used to obtain images of the cerebral vasculature after intraarterial contrast injections. In 12 instances, the intraarterial injections were recorded with both a digital subtraction unit and conventional direct magnification film-screen system. The digital subtraction and conventional film subtraction images were compared and graded for quality and information content by three skilled observers. In addition, quantitative measurements of contrast-detail performance and spatial resolution were obtained on both the digital system and the screen-film imaging chain. In a clinical setting, both the digital subtraction and conventional film-screen systems provided similar quality images and angiographic information. Contrast-detail curves demonstrated that digital subtraction angiography outperformed conventional film technique for low-contrast objects. Digital subtraction angiography also reduced the time required to obtain the angiogram, markedly reduced film cost, and lowered the contrast agent burden

  10. Collagen imaged by Coherent X-ray Diffraction: towards a complementary tool to conventional scanning SAXS

    International Nuclear Information System (INIS)

    Berenguer de la Cuesta, Felisa; Bean, Richard J; Bozec, Laurent; Robinson, Ian K; McCallion, Catriona; Wallace, Kris; Hiller, Jen C; Terrill, Nicholas J

    2010-01-01

    Third generation x-ray sources offer unique possibilities for exploiting coherence in the study of materials. New insights in the structure and dynamics of soft condensed matter and biological samples can be obtained by coherent x-ray diffraction (CXD). However, the experimental procedures for applying these methods to collagen tissues are still under development. We present here an investigation for the optimal procedure in order to obtain high quality CXD data from collagen tissues. Sample handling and preparation and adequate coherence defining apertures are among the more relevant factors to take into account. The impact of the results is also discussed, in particular in comparison with the information that can be extracted from conventional scanning small angle x-ray scattering (SAXS). Images of collagen tissues obtained by CXD reconstructions will give additional information about the local structure with higher resolution and will complement scanning SAXS images.

  11. Collagen imaged by Coherent X-ray Diffraction: towards a complementary tool to conventional scanning SAXS

    Energy Technology Data Exchange (ETDEWEB)

    Berenguer de la Cuesta, Felisa; Bean, Richard J; Bozec, Laurent; Robinson, Ian K [London Centre for Nanotechnology (LCN), University College London (UCL), London WC1H 0AH (United Kingdom); McCallion, Catriona; Wallace, Kris [Department of Physics and Astronomy, University College London (UCL), London WC1E 6BT (United Kingdom); Hiller, Jen C; Terrill, Nicholas J, E-mail: f.berenguer@ucl.ac.u [Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE (United Kingdom)

    2010-10-01

    Third generation x-ray sources offer unique possibilities for exploiting coherence in the study of materials. New insights in the structure and dynamics of soft condensed matter and biological samples can be obtained by coherent x-ray diffraction (CXD). However, the experimental procedures for applying these methods to collagen tissues are still under development. We present here an investigation for the optimal procedure in order to obtain high quality CXD data from collagen tissues. Sample handling and preparation and adequate coherence defining apertures are among the more relevant factors to take into account. The impact of the results is also discussed, in particular in comparison with the information that can be extracted from conventional scanning small angle x-ray scattering (SAXS). Images of collagen tissues obtained by CXD reconstructions will give additional information about the local structure with higher resolution and will complement scanning SAXS images.

  12. Added value of amide proton transfer imaging to conventional and perfusion MR imaging for evaluating the treatment response of newly diagnosed glioblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Park, Kye Jin; Kim, Ho Sung; Park, Ji Eun; Shim, Woo Hyun; Kim, Sang Joon [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology, Seoul (Korea, Republic of); Smith, Seth A. [Vanderbilt University Institute of Imaging Science, Vanderbilt University, Department of Radiology and Radiological Sciences, Nashville, TN (United States)

    2016-12-15

    To determine the added value of amide proton transfer (APT) imaging to conventional and perfusion MRI for differentiating tumour progression (TP) from the treatment-related effect (TE) in patients with post-treatment glioblastomas. Sixty-five consecutive patients with enlarging contrast-enhancing lesions following concurrent chemoradiotherapy were assessed using contrast-enhanced T1-weighted MRI (CE-T1WI), 90th percentile histogram parameters of normalized cerebral blood volume (nCBV90) and APT asymmetry value (APT90). Diagnostic performance was determined using the area under the receiver operating characteristic curve (AUC) and cross validations. There were statistically significant differences in the mean APT90 between the TP and the TE groups (3.87-4.01 % vs. 1.38-1.41 %; P <.001). Compared with CE-T1WI alone, the addition of APT90 to CE-T1WI significantly improved cross-validated AUC from 0.58-0.74 to 0.89-0.91 for differentiating TP from TE. The combination of CE-T1WI, nCBV90 and APT90 resulted in greater diagnostic accuracy for differentiating TP from TE than the combination of CE-T1WI and nCBV90 (cross-validated AUC, 0.95-0.97 vs. 0.84-0.91). The inter-reader agreement between the expert and trainee was excellent for the measurements of APT90 (intraclass correlation coefficient, 0.94). Adding APT imaging to conventional and perfusion MRI improves the diagnostic performance for differentiating TP from TE. (orig.)

  13. Object position and image magnification in dental panoramic radiography: a theoretical analysis.

    Science.gov (United States)

    Devlin, H; Yuan, J

    2013-01-01

    The purpose of our study was to investigate how image magnification and distortion in dental panoramic radiography are influenced by object size and position for a small round object such as a ball bearing used for calibration. Two ball bearings (2.5 mm and 6 mm in diameter) were placed at approximately the same position between the teeth of a plastic skull and radiographed 21 times. The skull was replaced each time. Their images were measured by software using edge detection and ellipse-fitting algorithms. Using a standard definition of magnification, equations were derived to enable an object's magnification to be determined from its position and vice versa knowing the diameter and machine parameters. The average magnification of the 2.5 mm ball bearing was 1.292 (0.0445) horizontally and 1.257 (0.0067) vertically with a mean ratio of 1.028 (0.0322); standard deviations are in parentheses. The figures for the 6 mm ball bearing were 1.286 (0.0068), 1.255 (0.0018) and 1.025 (0.0061), respectively. Derived positions of each ball bearing from magnification were more consistent horizontally than vertically. There was less variation in either direction for the 6 mm ball bearing than the 2.5 mm one. Automatic measurement of image size resulted in less variation in vertical magnification values than horizontal. There are only certain positions in the focal trough that achieve zero distortion. Object location can be determined from its diameter, measured magnification and machine parameters. The 6 mm diameter ball bearing is preferable to the 2.5 mm one for more reliable magnification measurement and position determination.

  14. Initial multicentre experience of high-speed myocardial perfusion imaging: comparison between high-speed and conventional single-photon emission computed tomography with angiographic validation

    Energy Technology Data Exchange (ETDEWEB)

    Neill, Johanne [University College London Hospital, Institute of Nuclear Medicine, London (United Kingdom); The Prince Charles Hospital, Brisbane (Australia); Prvulovich, Elizabeth M.; Bomanji, Jamshed B. [University College London Hospital, Institute of Nuclear Medicine, London (United Kingdom); Fish, Matthews B. [Sacred Heart Medical Center (SHMC), Springfield, OR (United States); Berman, Daniel S.; Slomka, Piotr J. [Cedars-Sinai Medical Center, Los Angeles, CA (United States); Sharir, Tali [Procardia Maccabi Healthcare Services (PMHS), Tel Aviv (Israel); Martin, William H. [Vanderbilt University Medical Center (VUMC), Nashville, TN (United States); DiCarli, Marcelo F. [Brigham and Women' s Hospital (BWH), Boston, MA (United States); Ziffer, Jack A. [Baptist Hospital of Miami (BHM), Miami, FL (United States); Shiti, Dalia [Spectrum-Dynamics, Caesarea (Israel); Ben-Haim, Simona [University College London Hospital, Institute of Nuclear Medicine, London (United Kingdom); Chaim Sheba Medical Center, Department of Nuclear Medicine, Tel-Hashomer (Israel)

    2013-07-15

    High-speed (HS) single-photon emission computed tomography (SPECT) with a recently developed solid-state camera shows comparable myocardial perfusion abnormalities to those seen in conventional SPECT. We aimed to compare HS and conventional SPECT images from multiple centres with coronary angiographic findings. The study included 50 patients who had sequential conventional SPECT and HS SPECT myocardial perfusion studies and coronary angiography within 3 months. Stress and rest perfusion images were visually analysed and scored semiquantitatively using a 17-segment model by two experienced blinded readers. Global and coronary territorial summed stress scores (SSS) and summed rest scores (SRS) were calculated. Global SSS {>=}3 or coronary territorial SSS {>=}2 was considered abnormal. In addition the total perfusion deficit (TPD) was automatically derived. TPD >5 % and coronary territorial TPD {>=}3 % were defined as abnormal. Coronary angiograms were analysed for site and severity of coronary stenosis; {>=}50 % was considered significant. Of the 50 patients, 13 (26 %) had no stenosis, 22 (44 %) had single-vessel disease, 6 (12 %) had double-vessel disease and 9 (18 %) had triple-vessel disease. There was a good linear correlation between the visual global SSS and SRS (Spearman's {rho} 0.897 and 0.866, respectively; p < 0.001). In relation to coronary angiography, the sensitivities, specificities and accuracies of HS SPECT and conventional SPECT by visual assessment were 92 % (35/38), 83 % (10/12) and 90 % (45/50) vs. 84 % (32/38), 50 % (6/12) and 76 % (38/50), respectively (p < 0.001). The sensitivities, specificities and accuracies of HS SPECT and conventional SPECT in relation to automated TPD assessment were 89 % (31/35), 57 % (8/14) and 80 % (39/49) vs. 86 % (31/36), 77 % (10/13) and 84 % (41/49), respectively. HS SPECT allows fast acquisition of myocardial perfusion images that correlate well with angiographic findings with overall accuracy by visual

  15. Are digital images good enough? A comparative study of conventional film-screen vs digital radiographs on printed images of total hip replacement

    International Nuclear Information System (INIS)

    Eklund, K.; Jonsson, K.; Lindblom, G.; Lundin, B.; Sanfridsson, J.; Sloth, M.; Sivberg, B.

    2004-01-01

    The aim of this study was to evaluate the inter- and intra-observer variability and to find differences in diagnostic safety between digital and analog technique in diagnostic zones around hip prostheses. In 80 patients who had had a total hip replacement (THR) for more than 2 years, a conventional image and a digital image were taken. Gruen's model of seven distinct regions of interest was used for evaluations. Five experienced radiologists observed the seven regions and noted in a protocol the following distances: stem-cement; cement-bone; and stem-bone. All images were printed on hard copies and were read twice. Weighted kappa, κ w , analyses were used. The two most frequently loosening regions, stem-cement region 1 and cement-bone region 7, were closely analyzed. In region 1 the five observers had an agreement of 86.75-97.92% between analog and digital images in stem-cement, which is a varied κ w 0.29-0.71. For cement-bone region 7 an agreement of 87.21-90.45% was found, which is a varied κ w of 0.48-0.58. All the kappa values differ significantly from nil. The result shows that digital technique is as good as analog radiographs for diagnosing possible loosening of hip prostheses. (orig.)

  16. Comparing ELISA test-positive prevalence, risk factors and management recommendations for Johne's disease prevention between organic and conventional dairy farms in Ontario, Canada.

    Science.gov (United States)

    Pieper, Laura; Sorge, Ulrike S; DeVries, Trevor; Godkin, Ann; Lissemore, Kerry; Kelton, David

    2015-11-01

    Johne's disease (JD) is a chronic, infectious disease in cattle. Between 2010 and 2013, a voluntary JD control program was successfully launched in Ontario, Canada, including a Risk Assessment and Management Plan (RAMP) and JD ELISA testing of the entire milking herd. Over the last decade, the organic dairy sector has been growing. However, organic farming regulations and philosophies may influence the risk for JD transmission on Ontario organic dairy farms. The aim of this cross-sectional study was to investigate differences in JD ELISA test positive prevalence, risk factors for JD and recommendations for JD prevention between organic and conventional dairy herds in Ontario. RAMP results (i.e. RAMP scores and recommendations) and ELISA results were available for 2103 dairy herds, including 42 organic herds. If available, additional data on milk production, milk quality, and herd characteristics were gathered. Organic and conventional herds had a similar herd-level JD ELISA test-positive prevalence (26.2% and 27.2%, respectively). Organic herds (4.2%) had a higher within-herd JD ELISA test-positive prevalence compared to conventional herds (2.3%) if they had at least one JD test-positive animal on the farm. Organic farms had lower risk scores for biosecurity (9 points lower), and higher scores in the calving (7 points higher) and the calf-rearing management areas (4 points higher). After accounting for RAMP score, organic farms received fewer recommendations for the calving management area (Odds Ratio=0.41) and more recommendations in the adult cow management area (Odds Ratio=2.70). A zero-inflated negative binomial model was built with purchase of animals and the herd size included in the logistic portion of the model. Herd type (organic or conventional), colostrum and milk feeding practices, average bulk tank somatic cell count, and presence of non-Holstein breeds were included in the negative binomial portion of the model. Organic farms had a higher number of

  17. Continuous monitoring of prostate position using stereoscopic and monoscopic kV image guidance

    Energy Technology Data Exchange (ETDEWEB)

    Stevens, M. Tynan R.; Parsons, Dave D.; Robar, James L. [Department of Medical Physics, Dalhousie University, Halifax, Nova Scotia B3H 4R2, Canada and Nova Scotia Cancer Centre, QEII Health Science Centre, Halifax, Nova Scotia B3H 2Y9 (Canada)

    2016-05-15

    Purpose: To demonstrate continuous kV x-ray monitoring of prostate motion using both stereoscopic and monoscopic localizations, assess the spatial accuracy of these techniques, and evaluate the dose delivered from the added image guidance. Methods: The authors implemented both stereoscopic and monoscopic fiducial localizations using a room-mounted dual oblique x-ray system. Recently developed monoscopic 3D position estimation techniques potentially overcome the issue of treatment head interference with stereoscopic imaging at certain gantry angles. To demonstrate continuous position monitoring, a gold fiducial marker was placed in an anthropomorphic phantom and placed on the Linac couch. The couch was used as a programmable translation stage. The couch was programmed with a series of patient prostate motion trajectories exemplifying five distinct categories: stable prostate, slow drift, persistent excursion, transient excursion, and high frequency excursions. The phantom and fiducial were imaged using 140 kVp, 0.63 mAs per image at 1 Hz for a 60 s monitoring period. Both stereoscopic and monoscopic 3D localization accuracies were assessed by comparison to the ground-truth obtained from the Linac log file. Imaging dose was also assessed, using optically stimulated luminescence dosimeter inserts in the phantom. Results: Stereoscopic localization accuracy varied between 0.13 ± 0.05 and 0.33 ± 0.30 mm, depending on the motion trajectory. Monoscopic localization accuracy varied from 0.2 ± 0.1 to 1.1 ± 0.7 mm. The largest localization errors were typically observed in the left–right direction. There were significant differences in accuracy between the two monoscopic views, but which view was better varied from trajectory to trajectory. The imaging dose was measured to be between 2 and 15 μGy/mAs, depending on location in the phantom. Conclusions: The authors have demonstrated the first use of monoscopic localization for a room-mounted dual x-ray system. Three

  18. Dual isotope, single acquisition parathyroid imaging

    International Nuclear Information System (INIS)

    Triantafillou, M.; McDonald, H.J.

    1998-01-01

    Full text: Nuclear Medicine parathyroid imaging using Thallium-201(TI) and Technetium-99m(Tc) is an often used imaging modality for the detection of parathyroid adenomas and hyper parathyroidism. The conventional Tl/Tc subtraction technique requires 2 separate injections and acquisitions which are then normalised and subtracted from each other. This lengthy technique is uncomfortable for patients and can result in false positive scan results due to patient movement between and during the acquisition process. We propose a simplified injection and single acquisition technique, that reduces the chance of movement and thus reduces the chance of false positive scan results. The technique involves the injection of Tc followed by the Tl injection 10 minutes later. After a further 10 min wait, imaging is performed using a dual isotope acquisition, with window (W) 1 set on 140 keV 20%W 5% off peak and W2 peaked for 70 keV 20%W., acquired for 10 minutes. We have imaged 27 patients with this technique, 15 had positive parathyroid imaging. Of the 15, 11 had positive ultrasound correlation. Of the remaining 4, 2 have had positive surgical findings for adenomas, the other 2 are awaiting follow-up. Of the 12 patients with negative parathyroid imaging, 2 have been shown to be false - negative with surgery. In conclusion, the single acquisition technique suggested by us is a valid method of imaging parathyroids that reduces the chance of false positive results due to movement

  19. Digital luminescence radiography and conventional radiography in abdominal contrast examinations

    International Nuclear Information System (INIS)

    Krug, B.; Harnischmacher, U.; Krahe, T.; Fischbach, R.; Altenburg, A.; Krings, F.

    1995-01-01

    In 326 patients abdominal contrast radiographs were compared to digital luminescence radiographs (DLR) and conventional screen-film system ones. The digital exposure dose was 50% of the conventional. In DLR, 2 different types of postprocessed images were obtained from each data set. A display with low spatial frequency enhancement filtered to look like a conventional radiograph was compared to a display with high spatial frequency enhancement. Conventional and DLR images were evaluated randomly and separately by 4 radiologists by means of a questionnaire. DLR proved to be diagnostically equivalent to the conventional technique with the exception of a slightly diminished visibility of the mucosal pattern. High spatial frequency enhancement did not provide additional diagnostic information and should be dispensed with in abdominal examinations. (orig.)

  20. Calibration tests and use of a Nicolet/Xentronics imaging proportional chamber mounted on a conventional source for protein crystallography

    Energy Technology Data Exchange (ETDEWEB)

    Derewenda, Z; Helliwell, J R

    1989-04-01

    The results are presented of calibration tests and several single-crystal X-ray data collection experiments undertaken with a Nicolet/Xentronics Imaging Proportional Counter mounted on a conventional X-ray source. Considerable attention has been given to system optimization in collaboration with Nicolet, and this has led to a performance of high quality. (orig.).

  1. Analyzing prospective teachers' images of scientists using positive, negative and stereotypical images of scientists

    Science.gov (United States)

    Subramaniam, Karthigeyan; Esprívalo Harrell, Pamela; Wojnowski, David

    2013-04-01

    Background and purpose : This study details the use of a conceptual framework to analyze prospective teachers' images of scientists to reveal their context-specific conceptions of scientists. The conceptual framework consists of context-specific conceptions related to positive, stereotypical and negative images of scientists as detailed in the literature on the images, role and work of scientists. Sample, design and method : One hundred and ninety-six drawings of scientists, generated by prospective teachers, were analyzed using the Draw-A-Scientist-Test Checklist (DAST-C), a binary linear regression and the conceptual framework. Results : The results of the binary linear regression analysis revealed a statistically significant difference for two DAST-C elements: ethnicity differences with regard to drawing a scientist who was Caucasian and gender differences for indications of danger. Analysis using the conceptual framework helped to categorize the same drawings into positive, stereotypical, negative and composite images of a scientist. Conclusions : The conceptual framework revealed that drawings were focused on the physical appearance of the scientist, and to a lesser extent on the equipment, location and science-related practices that provided the context of a scientist's role and work. Implications for teacher educators include the need to understand that there is a need to provide tools, like the conceptual framework used in this study, to help prospective teachers to confront and engage with their multidimensional perspectives of scientists in light of the current trends on perceiving and valuing scientists. In addition, teacher educators need to use the conceptual framework, which yields qualitative perspectives about drawings, together with the DAST-C, which yields quantitative measure for drawings, to help prospective teachers to gain a holistic outlook on their drawings of scientists.

  2. Effects of the change in cutoff values for human epidermal growth factor receptor 2 status by immunohistochemistry and fluorescence in situ hybridization: a study comparing conventional brightfield microscopy, image analysis-assisted microscopy, and interobserver variation.

    Science.gov (United States)

    Atkinson, Roscoe; Mollerup, Jens; Laenkholm, Anne-Vibeke; Verardo, Mark; Hawes, Debra; Commins, Deborah; Engvad, Birte; Correa, Adrian; Ehlers, Charlotte Cort; Nielsen, Kirsten Vang

    2011-08-01

    New guidelines for HER2 testing have been introduced. To evaluate the difference in HER2 assessment after introduction of new cutoff levels for both immunohistochemistry (IHC) and fluorescence in situ hybridization (FISH) and to compare interobserver agreement and time to score between image analysis and conventional microscopy. Samples from 150 patients with breast cancer were scored by 7 pathologists using conventional microscopy, with a cutoff of both 10% and 30% IHC-stained cells, and using automated microscopy with image analysis. The IHC results were compared individually and to HER2 status as determined by FISH, using both the approved cutoff of 2.0 and the recently introduced cutoff of 2.2. High concordance was found in IHC scoring among the 7 pathologists. The 30% cutoff led to slightly fewer positive IHC observations. Introduction of a FISH equivocal zone affected 4% of the FISH scores. If cutoff for FISH is kept at 2.0, no difference in patient selection is found between the 10% and the 30% IHC cutoff. Among the 150 breast cancer samples, the new 30% IHC and 2.2 FISH cutoff levels resulted in one case without a firm diagnosis because both IHC and FISH were equivocal. Automated microscopy and image analysis-assisted IHC led to significantly better interobserver agreement among the 7 pathologists, with an increase in mean scoring time of only about 30 seconds per slide. The change in cutoff levels led to a higher concordance between IHC and FISH, but fewer samples were classified as HER2 positive.

  3. Conventional diagnostic imaging of the temporal bone. A historical review

    International Nuclear Information System (INIS)

    Canigiani, G.

    1997-01-01

    The Viennese Medical School played an important role in the development of radiological examinations and signs of the temporal bone with conventional X-rays. Famous pioneers include E.G. Mayer (1893-1969) and L. Psenner (1910-1986). Nowadays conventional X-rays and tomography have lost their important role in diagnostic radiology of the temporal bone, but the basic principles established in those early years of radiology are still used now. This statement is correct not only for conventional X-rays, but particularly for 'poly'-tomography in comparison with CT. (orig.) [de

  4. Imaging with rotating slit apertures and rotating collimators

    International Nuclear Information System (INIS)

    Gindi, G.R.; Arendt, J.; Barrett, H.H.; Chiu, M.Y.; Ervin, A.; Giles, C.L.; Kujoory, M.A.; Miller, E.L.; Simpson, R.G.

    1982-01-01

    The statistical quality of conventional nuclear medical imagery is limited by the small signal collect through low-efficiency conventional apertures. Coded-aperture imaging overcomes this by employing a two-step process in which the object is first efficiently detected as an ''encoded'' form which does not resemble the object, and then filtered (or ''decoded'') to form an image. We present here the imaging properties of a class of time-modulated coded apertures which, unlike most coded apertures, encode projections of the object rather than the object itself. These coded apertures can reconstruct a volume object nontomographically, tomographically (one plane focused), or three-dimensionally. We describe a new decoding algorithm that reconstructs the object from its planar projections. Results of noise calculations are given, and the noise performance of these coded-aperture systems is compared to that of conventional counterparts. A hybrid slit-pinhole system which combines the imaging advantages of a rotating slit and a pinhole is described. A new scintillation detector which accurately measures the position of an event in one dimension only is presented, and its use in our coded-aperture system is outlined. Finally, results of imaging test objects and animals are given

  5. Imaging with rotating slit apertures and rotating collimators

    International Nuclear Information System (INIS)

    Gindi, G.R.; Arendt, J.; Barrett, H.H.; Chiu, M.Y.; Ervin, A.; Giles, C.L.; Kujoory, M.A.; Miller, E.L.; Simpson, R.G.

    1982-01-01

    The statistical quality of conventional nuclear medical imagery is limited by the small signal collected through low-efficiency conventional apertures. Coded-aperture imaging overcomes this by employing a two-step process in which the object is first efficiently detected as an encoded form which does not resemble the object, and then filtered (or decoded) to form an image. We present here the imaging properties of a class of time-modulated coded apertures which, unlike most coded apertures, encode projections of the object rather than the object itself. These coded apertures can reconstruct a volume object nontomographically, tomographically (one plane focused), or three-dimensionally. We describe a new decoding algorithm that reconstructs the object from its planar projections. Results of noise calculations are given, and the noise performance of these coded-aperture systems is compared to that of conventional counterparts. A hybrid slit-pinhole system which combines the imaging advantages of a rotating slit and a pinhole is described. A new scintillation detector which accurately measures the position of an event in one dimension only is presented, and its use in our coded-aperture system is outlined. Finally, results of imaging test objects and animals are given

  6. Digital radiography versus conventional radiography during excretory urography: our experience

    International Nuclear Information System (INIS)

    Cervi, P.M.; Bighi, S.; Merlo, L.; Lupi, L.; Vita, G.

    1990-01-01

    The authors describe a computed radiographic system employed to generate and archive digital images in intravenous urography. For each exposure the system produces two digital images: the first (left image) simulates a conventional screen-film radiograph, the second (right image); enhances some spatial frequencies and emphasizes the margins of the structures. These images can be modified in their chief parameters and then printed by a laser-printer and archived on optical disks. Four experienced radiologists evaluated digital images with regard to some chief diagnostic parameters and, in 50 patients, they compared digital images with conventional screen-film radiographs and submitted the results to statistical analysis. For some of the chosen parameters, particularly for the evaluation of renal margins before and after contrast medium injection, digital images gave statistically better results than conventional films, while, no statistically significant different was observed for the other parameters. From the results of this preliminary study digital radiography was found to be useful in intravenous urography by reducing the patient's exposition dose, by always obtaining images of good quality, and by enhancing some particular features of the standard image; on the other hand there were many unsolved problems regarding the communicating and archiving system (PACS), because of the slowness of the image transfer procedure, difficulties in data transmission and complexity of referential procedures

  7. [Contrastive study on conventional ultrasound, compression elastography and acoustic radiation force impulse imaging in the differential diagnosis of benign and malignant breast tumors].

    Science.gov (United States)

    Zhang, Lu; Zhou, Ping; Deng, Jin; Tian, Shuangming; Qian, Ying; Wu, Xiaomin; Ma, Shuhua; Li, Jiale

    2014-12-01

    To evaluate the diagnostic performance of conventional ultrasound, compression elastography (CE) and acoustic radiation force impulse imaging (ARFI) in differential diagnosis of benign and malignant breast tumors. A total of 98 patients with liver lesions were included in the study. The images of conventional ultrasound, CE and the values of virtual touch tissue quantification (VTQ) of breast lesions were obtained. The diagnostic performance of conventional ultrasound, CE and ARFI were assessed by using pathology as the gold standard, and then evaluate the diagnosis efficiency of these three approaches in differential diagnosing benign and malignant breast tumors. The specificity, sensitivity and accuracy in the diagnosis of malignant breast tumors for conventional ultrasound were 80.0%, 81.1% and 81.7%, respectively, whereas for CE elastic score were 85.7%, 86.7% and 86.3%, respectively. With a cutoff value of 3.71 for the SR, the sensitivity, specificity, accuracy in diagnosis of malignant breast tumors were 97.1%, 83.3% and 88.4%, respectively. With a cutoff value of 3.78 m/s for VTQ, the sensitivity, specificity, accuracy in diagnosis of malignant breast tumors were 94.3%, 91.7% and 92.6%, respectively. The difference in diagnosis efficiency among ARFI, CE and conventional ultrasound in differential diagnosis of benign and malignant breast tumors was significant (Pbenign and malignant breast tumors. But the diagnosis efficiency of ARFI is superior to CE and conventional ultrasound. The three approaches can help each other in differential diagnosis of benign and malignant breast tumors.

  8. Conventional versus virtual radiographs of the injured pelvis and acetabulum

    Energy Technology Data Exchange (ETDEWEB)

    Bishop, Julius A.; Rao, Allison J.; Pouliot, Michael A.; Bellino, Michael [Stanford University School of Medicine, Department of Orthopaedic Surgery, Stanford, CA (United States); Beaulieu, Christopher [Stanford University School of Medicine, Department of Radiology, Stanford, CA (United States)

    2015-09-15

    Evaluation of the fractured pelvis or acetabulum requires both standard radiographic evaluation as well as computed tomography (CT) imaging. The standard anterior-posterior (AP), Judet, and inlet and outlet views can now be simulated using data acquired during CT, decreasing patient discomfort, radiation exposure, and cost to the healthcare system. The purpose of this study is to compare the image quality of conventional radiographic views of the traumatized pelvis to virtual radiographs created from pelvic CT scans. Five patients with acetabular fractures and ten patients with pelvic ring injuries were identified using the orthopedic trauma database at our institution. These fractures were evaluated with both conventional radiographs as well as virtual radiographs generated from a CT scan. A web-based survey was created to query overall image quality and visibility of relevant anatomic structures. This survey was then administered to members of the Orthopaedic Trauma Association (OTA). Ninety-seven surgeons completed the acetabular fracture survey and 87 completed the pelvic fracture survey. Overall image quality was judged to be statistically superior for the virtual as compared to conventional images for acetabular fractures (3.15 vs. 2.98, p = 0.02), as well as pelvic ring injuries (2.21 vs. 1.45, p = 0.0001). Visibility ratings for each anatomic landmark were statistically superior with virtual images as well. Virtual radiographs of pelvic and acetabular fractures offer superior image quality, improved comfort, decreased radiation exposure, and a more cost-effective alternative to conventional radiographs. (orig.)

  9. Accuracy and reproducibility of tumor positioning during prolonged and multi-modality animal imaging studies

    International Nuclear Information System (INIS)

    Zhang Mutian; Huang Minming; Le, Carl; Zanzonico, Pat B; Ling, C Clifton; Koutcher, Jason A; Humm, John L; Claus, Filip; Kolbert, Katherine S; Martin, Kyle

    2008-01-01

    Dedicated small-animal imaging devices, e.g. positron emission tomography (PET), computed tomography (CT) and magnetic resonance imaging (MRI) scanners, are being increasingly used for translational molecular imaging studies. The objective of this work was to determine the positional accuracy and precision with which tumors in situ can be reliably and reproducibly imaged on dedicated small-animal imaging equipment. We designed, fabricated and tested a custom rodent cradle with a stereotactic template to facilitate registration among image sets. To quantify tumor motion during our small-animal imaging protocols, 'gold standard' multi-modality point markers were inserted into tumor masses on the hind limbs of rats. Three types of imaging examination were then performed with the animals continuously anesthetized and immobilized: (i) consecutive microPET and MR images of tumor xenografts in which the animals remained in the same scanner for 2 h duration, (ii) multi-modality imaging studies in which the animals were transported between distant imaging devices and (iii) serial microPET scans in which the animals were repositioned in the same scanner for subsequent images. Our results showed that the animal tumor moved by less than 0.2-0.3 mm over a continuous 2 h microPET or MR imaging session. The process of transporting the animal between instruments introduced additional errors of ∼0.2 mm. In serial animal imaging studies, the positioning reproducibility within ∼0.8 mm could be obtained.

  10. Trial making of a positive drawing phantom and its application to whole-body imaging devices

    International Nuclear Information System (INIS)

    Saegusa, Kenji; Arimizu, Noboru; Nakata, Tsuneo; Toyama, Haruo; Shiina, Isamu.

    1980-01-01

    In whole-body RI imaging, there are more instances of the positive pictures detecting the radioisotopes accumulating in morbid positions, such as Tc-99m bone scanning. The phantoms used to mutually compare RI imaging devices and to test their performance employ negative drawing targets embedded rather than positive ones. A simple positive drawing phantom has been made for trial, and applying this to whole-body scanning devices, the performance and the target drawing ability under different scanning conditions were comparatively examined. Though similar to Rollo's phantom, the phantom made for positive drawing uses acryl plate for its outer structure and target portions. The positive targets are cylindrical, and the diameters are 2, 4, 6, 8, 10, and 20 mm, and the subject contrasts are 5, 2, 1, 0.5 and 0.2. The aqueous solution of Tc-99m of about 2 mCi was injected into the phantom, and this was scanned with a whole-body camera and a multi-detector type whole-body scanner. With the phantom pictures close to actual clinical condition, the positive drawing phantom is conveniently capable of comparing the respective imaging devices for intended purposes. (J.P.N.)

  11. The effect of patient positioning on MR imaging of the internal auditory canal

    International Nuclear Information System (INIS)

    Daniels, D.L.; Czervionke, L.F.; Yu, S.; Ho, P.S.P.; Pech, P.; Pojunas, K.W.; Williams, A.L.; Haughton, V.M.

    1988-01-01

    Identification of individual cranial nerves and complete exclusion of tumor in the internal auditory canal may be difficult with MR, especially in imperfectly positioned patients. MR studies of the temporal bones in patients and in normal volunteers positioned non-rotated or canted were correlated with corresponding cryomicrotomic sections. Especially in axial images, oblique sectioning of cranial nerves VII and VIII may cause difficulty in identifying individual nerves. A combination of axial and coronal short TR and TE images can be used to confidently exclude intracanalicular tumor in most cases. (orig.)

  12. Effects of optimization and image processing in digital chest radiography

    International Nuclear Information System (INIS)

    Kheddache, S.; Maansson, L.G.; Angelhed, J.E.; Denbratt, L.; Gottfridsson, B.; Schlossman, D.

    1991-01-01

    A digital system for chest radiography based on a large image intensifier was compared to a conventional film-screen system. The digital system was optimized with regard to spatial and contrast resolution and dose. The images were digitally processed for contrast and edge enhancement. A simulated pneumothorax and two and two simulated nodules were positioned over the lungs and the mediastinum of an anthro-pomorphic phantom. Observer performance was evaluated with Receiver Operating Characteristic (ROC) analysis. Five observers assessed the processed digital images and the conventional full-size radiographs. The time spent viewing the full-size radiographs and the digital images was recorded. For the simulated pneumothorax, the results showed perfect performance for the full-size radiographs and detectability was high also for the processed digital images. No significant differences in the detectability of the simulated nodules was seen between the two imaging systems. The results for the digital images showed a significantly improved detectability for the nodules in the mediastinum as compared to a previous ROC study where no optimization and image processing was available. No significant difference in detectability was seen between the former and the present ROC study for small nodules in the lung. No difference was seen in the time spent assessing the conventional full-size radiographs and the digital images. The study indicates that processed digital images produced by a large image intensifier are equal in image quality to conventional full-size radiographs for low-contrast objects such as nodules. (author). 38 refs.; 4 figs.; 1 tab

  13. Elements of seismic imaging and velocity analysis – Forward modeling and diffraction analysis of conventional seismic data from the North Sea

    DEFF Research Database (Denmark)

    Montazeri, Mahboubeh

    2018-01-01

    comprises important oil and gas reservoirs. By application of well-established conventional velocity analysis methods and high-quality diffraction imaging techniques, this study aims to increase the resolution and the image quality of the seismic data. In order to analyze seismic wave propagation......-outs and salt delineations, which can be extracted from the diffractions. The potential of diffraction imaging techniques was studied for 2D seismic stacked data from the North Sea. In this approach, the applied plane-wave destruction method was successful in order to suppress the reflections from the stacked....... This improved seismic imaging is demonstrated for a salt structure as well as for Overpressured Shale structures and the Top Chalk of the North Sea....

  14. High spatial precision nano-imaging of polarization-sensitive plasmonic particles

    Science.gov (United States)

    Liu, Yunbo; Wang, Yipei; Lee, Somin Eunice

    2018-02-01

    Precise polarimetric imaging of polarization-sensitive nanoparticles is essential for resolving their accurate spatial positions beyond the diffraction limit. However, conventional technologies currently suffer from beam deviation errors which cannot be corrected beyond the diffraction limit. To overcome this issue, we experimentally demonstrate a spatially stable nano-imaging system for polarization-sensitive nanoparticles. In this study, we show that by integrating a voltage-tunable imaging variable polarizer with optical microscopy, we are able to suppress beam deviation errors. We expect that this nano-imaging system should allow for acquisition of accurate positional and polarization information from individual nanoparticles in applications where real-time, high precision spatial information is required.

  15. Comparison of conventional and automated breast volume ultrasound in the description and characterization of solid breast masses based on BI-RADS features.

    Science.gov (United States)

    Kim, Hyunji; Cha, Joo Hee; Oh, Ha-Yeun; Kim, Hak Hee; Shin, Hee Jung; Chae, Eun Young

    2014-07-01

    To compare the performance of radiologists in the use of conventional ultrasound (US) and automated breast volume ultrasound (ABVU) for the characterization of benign and malignant solid breast masses based on breast imaging and reporting data system (BI-RADS) criteria. Conventional US and ABVU images were obtained in 87 patients with 106 solid breast masses (52 cancers, 54 benign lesions). Three experienced radiologists who were blinded to all examination results independently characterized the lesions and reported a BI-RADS assessment category and a level of suspicion of malignancy. The results were analyzed by calculation of Cohen's κ coefficient and by receiver operating characteristic (ROC) analysis. Assessment of the agreement of conventional US and ABVU indicated that the posterior echo feature was the most discordant feature of seven features (κ = 0.371 ± 0.225) and that orientation had the greatest agreement (κ = 0.608 ± 0.210). The final assessment showed substantial agreement (κ = 0.773 ± 0.104). The areas under the ROC curves (Az) for conventional US and ABVU were not statistically significant for each reader, but the mean Az values of conventional US and ABVU by multi-reader multi-case analysis were significantly different (conventional US 0.991, ABVU 0.963; 95 % CI -0.0471 to -0.0097). The means for sensitivity, specificity, positive predictive value, and negative predictive value of conventional US and ABVU did not differ significantly. There was substantial inter-observer agreement in the final assessment of solid breast masses by conventional US and ABVU. ROC analysis comparing the performance of conventional US and ABVU indicated a marginally significant difference in mean Az, but not in mean sensitivity, specificity, positive predictive value, or negative predictive value.

  16. Integrated ultrasonic particle positioning and low excitation light fluorescence imaging

    International Nuclear Information System (INIS)

    Bernassau, A. L.; Al-Rawhani, M.; Beeley, J.; Cumming, D. R. S.

    2013-01-01

    A compact hybrid system has been developed to position and detect fluorescent micro-particles by combining a Single Photon Avalanche Diode (SPAD) imager with an acoustic manipulator. The detector comprises a SPAD array, light-emitting diode (LED), lenses, and optical filters. The acoustic device is formed of multiple transducers surrounding an octagonal cavity. By stimulating pairs of transducers simultaneously, an acoustic landscape is created causing fluorescent micro-particles to agglomerate into lines. The fluorescent pattern is excited by a low power LED and detected by the SPAD imager. Our technique combines particle manipulation and visualization in a compact, low power, portable setup

  17. A new position-sensitive transmission detector for epithermal neutron imaging

    International Nuclear Information System (INIS)

    Schooneveld, E M; Kockelmann, W; Rhodes, N; Tardocchi, M; Gorini, G; Perelli Cippo, E; Nakamura, T; Postma, H; Schillebeeckx, P

    2009-01-01

    A new neutron resonant transmission (NRT) detector for epithermal neutron imaging has been designed and built for the ANCIENT CHARM project, which is developing a set of complementary neutron imaging methods for analysis of cultural heritage objects. One of the techniques being exploited is NRT with the aim of performing bulk elemental analysis. The 16-pixel prototype NRT detector consists of independent crystals of 2 x 2 mm pixel size, which allow for 2D position-sensitive transmission measurements with epithermal neutrons. First results obtained at the ISIS pulsed spallation neutron source are presented. (fast track communication)

  18. Surgical neuro navigator guided by preoperative magnetic resonance images, based on a magnetic position sensor;Neuronavegador cirurgico guiado por imagens de ressonancia magnetica pre-operatoria, baseado num transdutor de posicao magnetico

    Energy Technology Data Exchange (ETDEWEB)

    Perini, Ana Paula; Siqueira, Rogerio Bulha; Carneiro, Antonio Adilton Oliveira, E-mail: adilton@ffclrp.usp.b [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Filosofia, Ciencias e Letras. Dept. de Fisica e Matematica; Oliveira, Lucas Ferrari de [Universidade Federal de Pelotas (UFPel), RS (Brazil). Dept. de Informatica; Machado, Helio Rubens [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Dept. de Neurocirurgia

    2009-08-15

    Image guided neurosurgery enables the neurosurgeon to navigate inside the patient's brain using pre-operative images as a guide and a tracking system, during a surgery. Following a calibration procedure, three-dimensional position and orientation of surgical instruments may be transmitted to computer. The spatial information is used to access a region of interest, in the pre-operative images, displaying them to the neurosurgeon during the surgical procedure. However, when a craniotomy is involved and the lesion is removed, movements of brain tissue can be a significant source of error in these conventional navigation systems. The architecture implemented in this work intends the development of a system to surgical planning and orientation guided by ultrasound image. For surgical orientation, the software developed allows the extraction of slices from the volume of the magnetic resonance images (MRI) with orientation supplied by a magnetic position sensor (Polhemus{sup R}). The slices extracted with this software are important because they show the cerebral area that the neurosurgeon is observing during the surgery, and besides they can be correlated with the intra-operative ultrasound images to detect and to correct the deformation of brain tissue during the surgery. Also, a tool for per-operative navigation was developed, providing three orthogonal planes through the image volume. In the methodology used for the software implementation, the Python{sup tm} programming language and the Visualization Toolkit (VTK) graphics library were used. The program to extract slices of the MRI volume allowed the application of transformations in the volume, using coordinates supplied by the position sensor. (author)

  19. Image quality at synthetic brain magnetic resonance imaging in children

    Energy Technology Data Exchange (ETDEWEB)

    Lee, So Mi; Cho, Seung Hyun; Kim, Won Hwa; Kim, Hye Jung [Kyungpook National University Hospital, Department of Radiology, Daegu (Korea, Republic of); Choi, Young Hun; Cheon, Jung-Eun; Kim, In-One [Seoul National University College of Medicine, Department of Radiology and Institute of Radiation Medicine, Seoul (Korea, Republic of); Cho, Hyun-Hae [Ewha Womans University Mokdong Hospital, Department of Radiology, Seoul (Korea, Republic of); You, Sun-Kyoung [Chungnam National University Hospital, Department of Radiology, Daejeon (Korea, Republic of); Park, Sook-Hyun [Kyungpook National University Hospital, Department of Pediatrics, Daegu (Korea, Republic of); Hwang, Moon Jung [GE Healthcare, MR Applications and Workflow, Seoul (Korea, Republic of)

    2017-11-15

    The clinical application of the multi-echo, multi-delay technique of synthetic magnetic resonance imaging (MRI) generates multiple sequences in a single acquisition but has mainly been used in adults. To evaluate the image quality of synthetic brain MR in children compared with that of conventional images. Twenty-nine children (median age: 6 years, range: 0-16 years) underwent synthetic and conventional imaging. Synthetic (T2-weighted, T1-weighted and fluid-attenuated inversion recovery [FLAIR]) images with settings matching those of the conventional images were generated. The overall image quality, gray/white matter differentiation, lesion conspicuity and image degradations were rated on a 5-point scale. The relative contrasts were assessed quantitatively and acquisition times for the two imaging techniques were compared. Synthetic images were inferior due to more pronounced image degradations; however, there were no significant differences for T1- and T2-weighted images in children <2 years old. The quality of T1- and T2-weighted images were within the diagnostically acceptable range. FLAIR images showed greatly reduced quality. Gray/white matter differentiation was comparable or better in synthetic T1- and T2-weighted images, but poorer in FLAIR images. There was no effect on lesion conspicuity. Synthetic images had equal or greater relative contrast. Acquisition time was approximately two-thirds of that for conventional sequences. Synthetic T1- and T2-weighted images were diagnostically acceptable, but synthetic FLAIR images were not. Lesion conspicuity and gray/white matter differentiation were comparable to conventional MRI. (orig.)

  20. Detection of lung nodules with low-dose spiral CT: comparison with conventional dose CT

    International Nuclear Information System (INIS)

    Zhu Tianzhao; Tang Guangjian; Jiang Xuexiang

    2004-01-01

    Objective: To investigate the effect of reducing scan dose on the lung nodules detection rate by scanning a lung nodule model at low dose and conventional dose. Methods: The lung and the thoracic cage were simulated by using a cyst filled with water surrounded by a roll bandage. Flour, butter, and paraffin wax were mixed together by a certain ratio to simulate lung nodules of 10 mm and 5 mm in diameter with the CT values ranging from -10 to 50 HU. Conventional-dose scan (240 mA, 140 kV) and low-dose scan of three different levels (43 mA, 140 kV; 50 mA, 120 kV; 75 mA, 80 kV) together with three different pitches (1.0, 1.5, and 2.0) were performed. The images of the simulated nodules were combined with the CT images of a normal adult's upper, middle, and inferior lung. Three radiologists read the images and the number of the nodules they detected including both the real ones and the false-positive ones was calculated to investigate weather there was any difference among different doses, pitch groups, and different locations. Results: The detection rate of the 10 mm and 5 mm nodules was 100% and 89.6% respectively by the low-dose scan. There was no difference between low-dose and conventional-dose CT (χ 2 =0.6907, P>0.70). The detection rate of 5 mm nodules declined when large pitch was used. Conclusion: The detection rates of 10 mm and 5 mm nodules had no difference between low-dose CT and conventional-dose CT. As the pitch augmented, the detection rate for the nodules declined

  1. The utility of MR imaging of the shoulder joint: comparison of the MR imaging between conventional MR imaging and arthrographic MR imaging

    International Nuclear Information System (INIS)

    Choi, Dong Sik; Ryu, Kyung Nam; Kim, Ihn Sub; Rhee, Yong Girl

    1998-01-01

    To evaluate the diagnostic value of MRI of the shoulder. Between January and June 1997, shoulder MRI and arthroscopy were performed in a total of 48 patients with shoulder pain (n=3D30) or shoulder instability (n=3D18). Forty-five were males and three were females; their ages ranged from 16 to 67 (mean 32.5) years. The period between shoulder MRI and arthroscopy was between one and 390 (mean, 42.2) days. Twenty-six patents underwent MR arthrography (AMR), and 22 conventional MRI(CMR). Each image was analyzed for rotator cuff injury, glenoid labral injury, SLAP lesion, and biceps tendon injury. On arthroscopy, one disease was found in 34 patients, two were found in six, three diseases were found in seven, and one patient had four diseases. Arthroscopic diagnosis was as follows:rotator cuff injury, 29;SLAP lesion, 12;glenoid labral injury, 10;biceps tendon injury, 4;subacromial bursitis, 2;chronic synovitis, 1;adhesive capsulitis, 1;superior glenohumeral ligament injury, 1;normal, 1. For rotator cuff injury, the sensitivity of MRI was 65.5% and specificity was 93.0% (AMR:66.7%, 95.8%, CMR:65.2%, 86.4%). For SLAP lesion, sensitivity was 58.3% and specificity was 97.2% (AMR:66.7%, 100%, CMR:50%, 93.8%);for glenoid labral injury, sensitivity was 80.0% and specificity was 89.5% (AMR:85.7%, 84.2%, CMR:66.7%, 94.7%), and for biceps tendon injury, the false negative rate was 100%. In cases involving glenoid labral injury, the diagnostic accuracy of shoulder MRI was relatively high;in rotator cuff injury and SLAP lesion, however, diagnosis was limited, and in biceps tendon injury was difficult. We suggest, however, that MR arthrography has certain diagnostic advantages over conventional MRI.=20

  2. The utility of MR imaging of the shoulder joint: comparison of the MR imaging between conventional MR imaging and arthrographic MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Dong Sik; Ryu, Kyung Nam; Kim, Ihn Sub; Rhee, Yong Girl [Kyunghee Univ., College of Medicine, Seoul (Korea, Republic of)

    1998-09-01

    To evaluate the diagnostic value of MRI of the shoulder. Between January and June 1997, shoulder MRI and arthroscopy were performed in a total of 48 patients with shoulder pain (n=3D30) or shoulder instability (n=3D18). Forty-five were males and three were females; their ages ranged from 16 to 67 (mean 32.5) years. The period between shoulder MRI and arthroscopy was between one and 390 (mean, 42.2) days. Twenty-six patents underwent MR arthrography (AMR), and 22 conventional MRI(CMR). Each image was analyzed for rotator cuff injury, glenoid labral injury, SLAP lesion, and biceps tendon injury. On arthroscopy, one disease was found in 34 patients, two were found in six, three diseases were found in seven, and one patient had four diseases. Arthroscopic diagnosis was as follows:rotator cuff injury, 29;SLAP lesion, 12;glenoid labral injury, 10;biceps tendon injury, 4;subacromial bursitis, 2;chronic synovitis, 1;adhesive capsulitis, 1;superior glenohumeral ligament injury, 1;normal, 1. For rotator cuff injury, the sensitivity of MRI was 65.5% and specificity was 93.0% (AMR:66.7%, 95.8%, CMR:65.2%, 86.4%). For SLAP lesion, sensitivity was 58.3% and specificity was 97.2% (AMR:66.7%, 100%, CMR:50%, 93.8%);for glenoid labral injury, sensitivity was 80.0% and specificity was 89.5% (AMR:85.7%, 84.2%, CMR:66.7%, 94.7%), and for biceps tendon injury, the false negative rate was 100%. In cases involving glenoid labral injury, the diagnostic accuracy of shoulder MRI was relatively high;in rotator cuff injury and SLAP lesion, however, diagnosis was limited, and in biceps tendon injury was difficult. We suggest, however, that MR arthrography has certain diagnostic advantages over conventional MRI.=20.

  3. Air-insufflated high-definition dacryoendoscopy yields significantly better image quality than conventional dacryoendoscopy

    Directory of Open Access Journals (Sweden)

    Sasaki T

    2017-08-01

    Full Text Available Tsugihisa Sasaki,1 Tsutomu Sounou,2 Hideki Tsuji,3 Kazuhisa Sugiyama4 1Sasaki Eye Clinic, Mikuni, Sakai, 2Department of Ophthalmology, Keiju Kanazawa Hospital, 3Department of Ophthalmology, Cancer Institute Hospital, 4Department of Ophthalmology and Visual Science, Kanazawa University Graduate School of Medical Science, Kanazawa, Japan Purpose: To facilitate the analysis of lacrimal conditions, we utilized high-definition dacryoendoscopy (HDD and undertook observations with a pressure-controlled air-insufflation system. We report the safety and performance of HDD.Methods: In this retrospective, non-randomized clinical trial, 46 patients (14 males and 32 females; age range 39–91 years; mean age ± SD 70.3±12.0 years who had lacrimal disorders were examined with HDD and conventional dacryoendoscopy (CD. The high-definition dacryoendoscope had 15,000 picture element image fibers and an advanced objective lens. Its outer diameter was 0.9–1.2 mm. Air insufflation was controlled at 0–20 kPa with a digital manometer-based pressure-controlled air-insufflation system to evaluate the quality of the image. The HDD had an air/saline irrigation channel between the outer sheath (outer diameter =1.2 mm and the metal inner sheath of the endoscope. We used it and the CD in air, saline, and diluted milk saline with and without manual irrigation to quantitatively evaluate the effect of air pressure and saline irrigation on image quality.Results: In vivo, the most significant improvement in image quality was demonstrated with air-insufflated (5–15 kPa HDD, as compared with saline-irrigated HDD and saline-irrigated CD. No emphysema or damage was noted under observation with HDD. In vitro, no significant difference was demonstrated between air-insufflated HDD and saline-irrigated HDD. In vitro, the image quality of air-insufflated HDD was significantly improved as compared with that of saline-irrigated CD.Conclusion: Pressure-controlled (5–15 kPa air

  4. Speckle-free and halo-free low coherent Mach-Zehnder quantitative-phase-imaging module as a replacement of objective lens in conventional inverted microscopes

    Science.gov (United States)

    Yamauchi, Toyohiko; Yamada, Hidenao; Matsui, Hisayuki; Yasuhiko, Osamu; Ueda, Yukio

    2018-02-01

    We developed a compact Mach-Zehnder interferometer module to be used as a replacement of the objective lens in a conventional inverted microscope (Nikon, TS100-F) in order to make them quantitative phase microscopes. The module has a 90-degree-flipped U-shape; the dimensions of the module are 160 mm by 120 mm by 40 mm and the weight is 380 grams. The Mach-Zehnder interferometer equipped with the separate reference and sample arms was implemented in this U-shaped housing and the path-length difference between the two arms was manually adjustable. The sample under test was put on the stage of the microscope and a sample light went through it. Both arms had identical achromatic lenses for image formation and the lateral positions of them were also manually adjustable. Therefore, temporally and spatially low coherent illumination was applicable because the users were able to balance precisely the path length of the two arms and to overlap the two wavefronts. In the experiment, spectrally filtered LED light for illumination (wavelength = 633 nm and bandwidth = 3 nm) was input to the interferometer module via a 50 micrometer core optical fiber. We have successfully captured full-field interference images by a camera put on the trinocular tube of the microscope and constructed quantitative phase images of the cultured cells by means of the quarter-wavelength phase shifting algorithm. The resultant quantitative phase images were speckle-free and halo-free due to spectrally and spatially low coherent illumination.

  5. Non-Imaging Speckle Interferometry forHigh Speed Nanometer-Scale Position Detection

    OpenAIRE

    van Putten, E. G.; Lagendijk, A.; Mosk, A. P.

    2011-01-01

    We experimentally demonstrate a non-imaging approach to displacement measurement for complex scattering materials. By spatially controlling the wave front of the light that incidents on the material we concentrate the scattered light in a focus on a designated position. This wave front acts as an unique optical fingerprint that enables precise position detection of the illuminated material by simply measuring the intensity in the focus. By combining two optical fingerprints we demonstrate pos...

  6. Determination of tolerances in the positioning of the treatment table from an image-guided system

    International Nuclear Information System (INIS)

    Perez Moreno, J. M.; Zucca Aparicio, D.; Fernandez leton, P.; Garcia Ruiz-Zorrilla, J.; Minanbres Moro, A.

    2011-01-01

    The use of techniques of image-guided radiotherapy (TGRT) aims to reduce the uncertainties associated with patient positioning. One of the techniques more recent development is the cone beam CT (CBCT), consisting of the acquisition of volumetric images of the patient by a detector integrated into the linear accelerator. By analyzing the results of all sessions of treatment to all patients in which the positioning has been carried out with image-guided system MV CBCT have been determined tolerance tables for translational coordinates of the table treatment based on pathology and immobilization system used. (Author)

  7. Comparison of positive and negative enteral contrast agents for MR imaging of the abdomen

    International Nuclear Information System (INIS)

    Kaminsky, S.; Langer, M.

    1994-01-01

    Following oral administration of a buffered gadopentetate-dimeglumine solution (Magnevist enteral R , 1 mmol/l, 6-17 ml/kg) T 1 -, proton-density- and T 2 -weighted spin-echo images of abdominal and retroperitoneal lesions were acquired (0.5 T). Gadopentetate is a signal-enhancing, positive MR contrast agent, intraluminar air served as a model of a signal-free, negative agent. In 21 patients contrast/noise ratios of gadopentetate and air versus lesions and fat were compared quantitatively (t-test). In T 1 - and T 2 -weighted images contrast/noise ratios of gadopentetate versus lesions were significantly higher than those of air. In proton-density images there was no significant difference. In T 1 - and proton-density images contrast/noise ratios of air versus abdominal fat were significantly higher than those of gadopentetate, in T 2 -weighted images gadopentetate had a significantly higher contrast/noise ratio than air. Signal-enhancing positive contrast agents seem advantageous over signal-free negative enteral MR contrast agents. (orig.) [de

  8. Are digital images good enough? A comparative study of conventional film-screen vs digital radiographs on printed images of total hip replacement

    Energy Technology Data Exchange (ETDEWEB)

    Eklund, K.; Jonsson, K.; Lindblom, G.; Lundin, B.; Sanfridsson, J.; Sloth, M. [Department of Radiology, Center for Medical Imaging and Physiology, Lund University Hospital, 22185, Lund (Sweden); Sivberg, B. [Department of Nursing, Faculty of Medicine, Lund University, P.O. Box 157, 22100, Lund (Sweden)

    2004-05-01

    The aim of this study was to evaluate the inter- and intra-observer variability and to find differences in diagnostic safety between digital and analog technique in diagnostic zones around hip prostheses. In 80 patients who had had a total hip replacement (THR) for more than 2 years, a conventional image and a digital image were taken. Gruen's model of seven distinct regions of interest was used for evaluations. Five experienced radiologists observed the seven regions and noted in a protocol the following distances: stem-cement; cement-bone; and stem-bone. All images were printed on hard copies and were read twice. Weighted kappa, {kappa}{sub w}, analyses were used. The two most frequently loosening regions, stem-cement region 1 and cement-bone region 7, were closely analyzed. In region 1 the five observers had an agreement of 86.75-97.92% between analog and digital images in stem-cement, which is a varied {kappa}{sub w} 0.29-0.71. For cement-bone region 7 an agreement of 87.21-90.45% was found, which is a varied {kappa}{sub w} of 0.48-0.58. All the kappa values differ significantly from nil. The result shows that digital technique is as good as analog radiographs for diagnosing possible loosening of hip prostheses. (orig.)

  9. Timing and position response of a block detector for fast neutron time-of-flight imaging

    Energy Technology Data Exchange (ETDEWEB)

    Laubach, M.A., E-mail: mlaubach@utk.edu [Department of Nuclear Engineering, University of Tennessee, Knoxville, TN 37996 (United States); Hayward, J.P., E-mail: jhayward@utk.edu [Department of Nuclear Engineering, University of Tennessee, Knoxville, TN 37996 (United States); Oak Ridge National Laboratory, 1 Bethel Valley Rd., Oak Ridge, TN 37831 (United States); Zhang, X., E-mail: xzhang39@utk.edu [Department of Nuclear Engineering, University of Tennessee, Knoxville, TN 37996 (United States); Cates, J.W., E-mail: jcates7@vols.utk.edu [Department of Nuclear Engineering, University of Tennessee, Knoxville, TN 37996 (United States)

    2014-11-01

    Our research effort seeks to improve the spatial and timing performance of a block detector made of a pixilated plastic scintillator (EJ-200), first demonstrated as part of Oak Ridge National Laboratory's Advanced Portable Neutron Imaging System. Improvement of the position and time response is necessary to achieve better resolution and contrast in the images of shielded special nuclear material. Time-of-flight is used to differentiate between gamma and different sources of neutrons (e.g., transmission and fission neutrons). Factors limiting the timing and position performance of the neutron detector have been revealed through simulations and measurements. Simulations have suggested that the degradation in the ability to resolve pixels in the neutron detector is due to those interactions occurring near the light guide. The energy deposition within the neutron detector is shown to affect position performance and imaging efficiency. This examination details how energy cuts improve the position performance and degrade the imaging efficiency. Measurements have shown the neutron detector to have a timing resolution of σ=238 ps. The majority of this timing uncertainty is from the depth-of-interaction (DOI) of the neutron which is confirmed by simulations and analytical calculations.

  10. Long axial imaging range using conventional swept source lasers in optical coherence tomography via re-circulation loops

    Science.gov (United States)

    Bradu, Adrian; Jackson, David A.; Podoleanu, Adrian

    2018-03-01

    Typically, swept source optical coherence tomography (SS-OCT) imaging instruments are capable of a longer axial range than their camera based (CB) counterpart. However, there are still various applications that would take advantage for an extended axial range. In this paper, we propose an interferometer configuration that can be used to extend the axial range of the OCT instruments equipped with conventional swept-source lasers up to a few cm. In this configuration, the two arms of the interferometer are equipped with adjustable optical path length rings. The use of semiconductor optical amplifiers in the two rings allows for compensating optical losses hence, multiple paths depth reflectivity profiles (Ascans) can be combined axially. In this way, extremely long overall axial ranges are possible. The use of the recirculation loops produces an effect equivalent to that of extending the coherence length of the swept source laser. Using this approach, the achievable axial imaging range in SS-OCT can reach values well beyond the limit imposed by the coherence length of the laser, to exceed in principle many centimeters. In the present work, we demonstrate axial ranges exceeding 4 cm using a commercial swept source laser and reaching 6 cm using an "in-house" swept source laser. When used in a conventional set-up alone, both these lasers can provide less than a few mm axial range.

  11. Reinforcing the role of the conventional C-arm--a novel method for simplified distal interlocking.

    Science.gov (United States)

    Windolf, Markus; Schroeder, Josh; Fliri, Ladina; Dicht, Benno; Liebergall, Meir; Richards, R Geoff

    2012-01-25

    The common practice for insertion of distal locking screws of intramedullary nails is a freehand technique under fluoroscopic control. The process is technically demanding, time-consuming and afflicted to considerable radiation exposure of the patient and the surgical personnel. A new concept is introduced utilizing information from within conventional radiographic images to help accurately guide the surgeon to place the interlocking bolt into the interlocking hole. The newly developed technique was compared to conventional freehand in an operating room (OR) like setting on human cadaveric lower legs in terms of operating time and radiation exposure. The proposed concept (guided freehand), generally based on the freehand gold standard, additionally guides the surgeon by means of visible landmarks projected into the C-arm image. A computer program plans the correct drilling trajectory by processing the lens-shaped hole projections of the interlocking holes from a single image. Holes can be drilled by visually aligning the drill to the planned trajectory. Besides a conventional C-arm, no additional tracking or navigation equipment is required.Ten fresh frozen human below-knee specimens were instrumented with an Expert Tibial Nail (Synthes GmbH, Switzerland). The implants were distally locked by performing the newly proposed technique as well as the conventional freehand technique on each specimen. An orthopedic resident surgeon inserted four distal screws per procedure. Operating time, number of images and radiation time were recorded and statistically compared between interlocking techniques using non-parametric tests. A 58% reduction in number of taken images per screw was found for the guided freehand technique (7.4 ± 3.4) (mean ± SD) compared to the freehand technique (17.6 ± 10.3) (p < 0.001). Total radiation time (all 4 screws) was 55% lower for the guided freehand technique compared to conventional freehand (p = 0.001). Operating time per screw (from first

  12. Continuous positive airway pressure and conventional mechanical ventilation in the treatment of meconium aspiration syndrome.

    Science.gov (United States)

    Goldsmith, J P

    2008-12-01

    Meconium aspiration syndrome (MAS) is a complex syndrome that ranges in severity from mild respiratory distress to severe respiratory failure, persistent pulmonary hypertension of the newborn and sometimes death. Understanding of the syndrome's complicated pathophysiology will help determine the appropriate treatment strategy, including the use of continuous positive airway pressure (CPAP), conventional mechanical ventilation (CMV) and other therapies. Approximately 30 to 50% of infants diagnosed with MAS will require CPAP or mechanical ventilation. The optimum modes of ventilation for MAS are not known. Very few studies have been conducted to determine 'best' ventilatory strategies. Despite the introduction, over the last two decades, of innovative ventilatory treatments for this disease (for example, surfactant, high-frequency ventilation, inhaled nitric oxide, extracorporeal membrane oxygenation), the majority of infants can be successfully managed with CPAP or mechanical ventilation alone.

  13. Novel imaging strategies for upper gastrointestinal tract cancers

    DEFF Research Database (Denmark)

    Mortensen, Michael Bau

    2015-01-01

    Accurate pretherapeutic imaging is the cornerstone of all cancer treatment. Unfortunately, modern imaging modalities have several unsolved problems and limitations. The differentiation between inflammation and cancer infiltration, false positive and false negative findings as well as lack...... of confirming biopsies in suspected metastases may have serious negative consequences in cancer patients. This review describes some of these problems and challenges the use of conventional imaging by suggesting new combined strategies that include selective use of confirming biopsies and complementary methods...

  14. Impact of body image on patients' attitude towards conventional, minimal invasive, and natural orifice surgery.

    Science.gov (United States)

    Lamadé, Wolfram; Friedrich, Colin; Ulmer, Christoph; Basar, Tarkan; Weiss, Heinz; Thon, Klaus-Peter

    2011-03-01

    A series of investigations proposed that patients' preference on minimal invasive and scarless surgery may be influenced by age, sex, and surgical as well as endoscopic history of the individual patient. However, it is unknown which psychological criteria lead to the acceptance of increased personal surgical risk or increased personal expenses in patients demanding scarless operations. We investigated whether individual body image contributes to the patient's readiness to assume higher risk in favor of potentially increased cosmesis. We conducted a nonrandomized survey among 63 consecutive surgical patients after receiving surgery. Individual body image perception was assessed postoperatively applying the FKB-20 questionnaire extended by four additional items. The FKB-20 questionnaire is a validated tool for measuring body image disturbances resulting in a two-dimensional score with negative body image (NBI) and vital body dynamics (VBD) being the two resulting scores. A subgroup analysis was performed according to the conducted operations: conventional open surgery = group 1, traditional laparoscopic surgery = group 2, and no scar surgery = group 3. There was a significant correlation between a negative body image and the preference for scar sparing and scarless surgery indicated by a significantly increased acceptance of surgical risks and the willingness to spend additional money for receiving scarless surgery (r = 0.333; p = 0.0227). Allocated to operation subgroups, 17 of 63 patients belonged to group 1 (OS), 29 to group 2 (minimally invasive surgery), and 17 patients to group 3 (no scar). Although age and sex were unequally distributed, the groups were homogenous regarding body mass index and body image (NBI). Subgroup analysis revealed that postoperative desire for scar sparing approaches was most frequently expressed by patients who received no scar operations. Patients with an NBI tend towards scarless surgery and are willing to accept increased

  15. Depth of focus enhancement of a modified imaging quasi-fractal zone plate.

    Science.gov (United States)

    Zhang, Qinqin; Wang, Jingang; Wang, Mingwei; Bu, Jing; Zhu, Siwei; Gao, Bruce Z; Yuan, Xiaocong

    2012-10-01

    We propose a new parameter w for optimization of foci distribution of conventional fractal zone plates (FZPs) with a greater depth of focus (DOF) in imaging. Numerical simulations of DOF distribution on axis directions indicate that the values of DOF can be extended by a factor of 1.5 or more by a modified quasi-FZP. In experiments, we employ a simple object-lens-image-plane arrangement to pick up images at various positions within the DOF of a conventional FZP and a quasi-FZP, respectively. Experimental results show that the parameter w improves foci distribution of FZPs in good agreement with theoretical predictions.

  16. Design of a Single-Cell Positioning Controller Using Electroosmotic Flow and Image Processing

    Directory of Open Access Journals (Sweden)

    Jhong-Yin Chen

    2013-05-01

    Full Text Available The objective of the current research was not only to provide a fast and automatic positioning platform for single cells, but also improved biomolecular manipulation techniques. In this study, an automatic platform for cell positioning using electroosmotic flow and image processing technology was designed. The platform was developed using a PCI image acquisition interface card for capturing images from a microscope and then transferring them to a computer using human-machine interface software. This software was designed by the Laboratory Virtual Instrument Engineering Workbench, a graphical language for finding cell positions and viewing the driving trace, and the fuzzy logic method for controlling the voltage or time of an electric field. After experiments on real human leukemic cells (U-937, the success of the cell positioning rate achieved by controlling the voltage factor reaches 100% within 5 s. A greater precision is obtained when controlling the time factor, whereby the success rate reaches 100% within 28 s. Advantages in both high speed and high precision are attained if these two voltage and time control methods are combined. The control speed with the combined method is about 5.18 times greater than that achieved by the time method, and the control precision with the combined method is more than five times greater than that achieved by the voltage method.

  17. A prospective comparison of patient body image after robotic thyroidectomy and conventional open thyroidectomy in patients with papillary thyroid carcinoma.

    Science.gov (United States)

    Lee, Sohee; Kim, Ha Yan; Lee, Cho Rok; Park, Seulkee; Son, Haiyoung; Kang, Sang-Wook; Jeong, Jong Ju; Nam, Kee-Hyun; Chung, Woong Youn; Park, Cheong Soo

    2014-07-01

    Body image is associated with self-esteem and identity and has a close relationship with quality of life (QoL). We compared the impact of surgical scars on the patient's perception of body image between conventional open thyroidectomy (OT) and robotic thyroidectomy (RT) in female papillary thyroid carcinoma patients. From October 2009 to December 2010, we enrolled prospectively 116 papillary thyroid carcinoma patients who underwent total thyroidectomy at the Yonsei University Health System (Seoul, Korea). Of these 116 patients, 56 had OT and 60 RT. Their scars were assessed using the Vancouver Scar Scale (VSS), and psychometric properties were evaluated using the Body Image Scale (BIS) questionnaire postoperatively. Both groups were compared using cross-sectional and time-series methods. Mean age was significantly younger in the RT group. Regarding scar quality, the OT group showed superiority in scar pigmentation and the total VSS score during the early postoperative period, but the VSS score improved over time and was similar between both groups at 9 months. The RT group had better scores regarding most of the BIS items, a trend that remained relatively constant over time. In patients with noticeable scars (VSS ≥ 2) at 9 months, the RT group had better BIS scores regarding almost all items, including "self-conscious," "physical attractiveness," "feeling of less feminine," "sexual attractiveness," "dissatisfaction with body, scar and appearance when dressed," and "avoidance of people due to appearance." RT provides a better self-body image and improves QoL compared with conventional OT by avoiding a noticeable cervical scar. Copyright © 2014 Mosby, Inc. All rights reserved.

  18. Three-dimensional reconstruction of functional brain images

    International Nuclear Information System (INIS)

    Inoue, Masato; Shoji, Kazuhiko; Kojima, Hisayoshi; Hirano, Shigeru; Naito, Yasushi; Honjo, Iwao

    1999-01-01

    We consider PET (positron emission tomography) measurement with SPM (Statistical Parametric Mapping) analysis to be one of the most useful methods to identify activated areas of the brain involved in language processing. SPM is an effective analytical method that detects markedly activated areas over the whole brain. However, with the conventional presentations of these functional brain images, such as horizontal slices, three directional projection, or brain surface coloring, makes understanding and interpreting the positional relationships among various brain areas difficult. Therefore, we developed three-dimensionally reconstructed images from these functional brain images to improve the interpretation. The subjects were 12 normal volunteers. The following three types of images were constructed: routine images by SPM, three-dimensional static images, and three-dimensional dynamic images, after PET images were analyzed by SPM during daily dialog listening. The creation of images of both the three-dimensional static and dynamic types employed the volume rendering method by VTK (The Visualization Toolkit). Since the functional brain images did not include original brain images, we synthesized SPM and MRI brain images by self-made C++ programs. The three-dimensional dynamic images were made by sequencing static images with available software. Images of both the three-dimensional static and dynamic types were processed by a personal computer system. Our newly created images showed clearer positional relationships among activated brain areas compared to the conventional method. To date, functional brain images have been employed in fields such as neurology or neurosurgery, however, these images may be useful even in the field of otorhinolaryngology, to assess hearing and speech. Exact three-dimensional images based on functional brain images are important for exact and intuitive interpretation, and may lead to new developments in brain science. Currently, the surface

  19. Three-dimensional reconstruction of functional brain images

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, Masato; Shoji, Kazuhiko; Kojima, Hisayoshi; Hirano, Shigeru; Naito, Yasushi; Honjo, Iwao [Kyoto Univ. (Japan)

    1999-08-01

    We consider PET (positron emission tomography) measurement with SPM (Statistical Parametric Mapping) analysis to be one of the most useful methods to identify activated areas of the brain involved in language processing. SPM is an effective analytical method that detects markedly activated areas over the whole brain. However, with the conventional presentations of these functional brain images, such as horizontal slices, three directional projection, or brain surface coloring, makes understanding and interpreting the positional relationships among various brain areas difficult. Therefore, we developed three-dimensionally reconstructed images from these functional brain images to improve the interpretation. The subjects were 12 normal volunteers. The following three types of images were constructed: routine images by SPM, three-dimensional static images, and three-dimensional dynamic images, after PET images were analyzed by SPM during daily dialog listening. The creation of images of both the three-dimensional static and dynamic types employed the volume rendering method by VTK (The Visualization Toolkit). Since the functional brain images did not include original brain images, we synthesized SPM and MRI brain images by self-made C++ programs. The three-dimensional dynamic images were made by sequencing static images with available software. Images of both the three-dimensional static and dynamic types were processed by a personal computer system. Our newly created images showed clearer positional relationships among activated brain areas compared to the conventional method. To date, functional brain images have been employed in fields such as neurology or neurosurgery, however, these images may be useful even in the field of otorhinolaryngology, to assess hearing and speech. Exact three-dimensional images based on functional brain images are important for exact and intuitive interpretation, and may lead to new developments in brain science. Currently, the surface

  20. NON-CONVENTIONAL PET NUCLIDES: PRODUCTION AND IMAGING

    OpenAIRE

    Laforest, Richard

    2015-01-01

    Abstract Medical cyclotrons are now commonly used for the production of PET nuclides by the (pn) reaction. These devices are typically capable of delivering 10-15 MeV protons beams at sufficiently high intensity for timely production of β+ decaying nuclides. Non-conventional PET nuclides have emerged recently and offers new opportunities for diagnostic and therapy drug discovery. In this paper, we will review the production capabilities for such nuclides at Washington University Medical Schoo...

  1. Side-Scan Sonar Image Mosaic Using Couple Feature Points with Constraint of Track Line Positions

    Directory of Open Access Journals (Sweden)

    Jianhu Zhao

    2018-06-01

    Full Text Available To obtain large-scale seabed surface image, this paper proposes a side-scan sonar (SSS image mosaic method using couple feature points (CFPs with constraint of track line positions. The SSS geocoded images are firstly used to form a coarsely mosaicked one and the overlapping areas between adjacent strip images can be determined based on geographic information. Inside the overlapping areas, the feature point (FP detection and registration operation are adopted for both strips. According to the detected CFPs and track line positions, an adjustment model is established to accommodate complex local distortions as well as ensure the global stability. This proposed method effectively solves the problem of target ghosting or dislocation and no accumulated errors arise in the mosaicking process. Experimental results show that the finally mosaicked image correctly reflects the object distribution, which is meaningful for understanding and interpreting seabed topography.

  2. Patient positioning and its influence on dose distribution

    International Nuclear Information System (INIS)

    Morrissey, J.; Moss, R.; Watkins, P.

    2000-01-01

    In comparison to conventional radiotherapy, the positioning of a patient for BNCT treatment has some unique aspects. In particular, the neutron beam coming from the core of a nuclear research reactor is fixed and horizontal. In particular, a head fixation mask, which is prepared at the patient referral hospital, is included in the CT images. The mask allows reproducible positioning for use during the treatment. Fiducial markers placed on the mask before imaging, provide reference points. The INEEL treatment planning code used in Petten produces a beam angle, and beam line entrance and exit co-ordinates. These are related to the fiducial marker co-ordinates. A spreadsheet, named COSINE, developed at Petten produces positioning co-ordinates from the data produced by the rtt MC code. These co-ordinates are related to a positioning frame, which allows the marking of the beams on the mask. In order to have reliable treatment data, the influence of small deviations of angle or target point on dose distribution must be known. To demonstrate this, a number of beams have been calculated with the Petten beam, with slight variations and compared with an approved plan. (author)

  3. Automatic online and real-time tumour motion monitoring during stereotactic liver treatments on a conventional linac by combined optical and sparse monoscopic imaging with kilovoltage x-rays (COSMIK)

    Science.gov (United States)

    Bertholet, Jenny; Toftegaard, Jakob; Hansen, Rune; Worm, Esben S.; Wan, Hanlin; Parikh, Parag J.; Weber, Britta; Høyer, Morten; Poulsen, Per R.

    2018-03-01

    The purpose of this study was to develop, validate and clinically demonstrate fully automatic tumour motion monitoring on a conventional linear accelerator by combined optical and sparse monoscopic imaging with kilovoltage x-rays (COSMIK). COSMIK combines auto-segmentation of implanted fiducial markers in cone-beam computed tomography (CBCT) projections and intra-treatment kV images with simultaneous streaming of an external motion signal. A pre-treatment CBCT is acquired with simultaneous recording of the motion of an external marker block on the abdomen. The 3-dimensional (3D) marker motion during the CBCT is estimated from the auto-segmented positions in the projections and used to optimize an external correlation model (ECM) of internal motion as a function of external motion. During treatment, the ECM estimates the internal motion from the external motion at 20 Hz. KV images are acquired every 3 s, auto-segmented, and used to update the ECM for baseline shifts between internal and external motion. The COSMIK method was validated using Calypso-recorded internal tumour motion with simultaneous camera-recorded external motion for 15 liver stereotactic body radiotherapy (SBRT) patients. The validation included phantom experiments and simulations hereof for 12 fractions and further simulations for 42 fractions. The simulations compared the accuracy of COSMIK with ECM-based monitoring without model updates and with model updates based on stereoscopic imaging as well as continuous kilovoltage intrafraction monitoring (KIM) at 10 Hz without an external signal. Clinical real-time tumour motion monitoring with COSMIK was performed offline for 14 liver SBRT patients (41 fractions) and online for one patient (two fractions). The mean 3D root-mean-square error for the four monitoring methods was 1.61 mm (COSMIK), 2.31 mm (ECM without updates), 1.49 mm (ECM with stereoscopic updates) and 0.75 mm (KIM). COSMIK is the first combined kV/optical real-time motion

  4. THE USE OF PUBLIC RELATIONS IN PROJECTING AN ORGANIZATION'S POSITIVE IMAGE

    Directory of Open Access Journals (Sweden)

    Ioana Olariu

    2017-07-01

    Full Text Available This article is a theoretical approach on the importance of using public relations in helping an organization to project a positive image. The study of the impact information has on the image of organisations seems to be an interesting research topic. Practice has proved that the image of institutions has a patrimonial value and it is sometimes essential in raising their credibility. It can be said that an image is defined as the representation of certain attitudes, opinions or prejudices concerning a person, a group of persons or the public opinion concerning an institution. In other words, an image is the opinion of a person, of a group of persons or of the public opinion regarding that institution. All specialists agree that a negative image affects, sometimes to an incredible extent, the success of an institution. In the contemporary age, we cannot speak about public opinion without taking into consideration the mass media as a main agent in transmitting the information to the public, with unlimited possibilities of influencing or forming it. The plan for the PR department starts with its own declaration of principles, which describes its roles and contribution to the organisation.

  5. Automatic Compensation of Workpiece Positioning Tolerances for Precise Laser

    Directory of Open Access Journals (Sweden)

    N. C. Stache

    2008-01-01

    Full Text Available Precise laser welding plays a fundamental role in the production of high-tech goods, particularly in precision engineering. In this working field, precise adjustment and compensation of positioning tolerances of the parts to be welded with respect to the laser beam is of paramount importance. This procedure mostly requires tedious and error-prone manual adjustment, which additionally results in a sharp increase in production costs. We therefore developed a system which automates and thus accelerates this procedure significantly. To this end, the welding machine is equipped with a camera to acquire high resolution images of the parts to be welded. In addition, a software framework is developed which enables precise automatic position detection of these parts and adjusts the position of the welding contour correspondingly. As a result, the machine is rapidly prepared for welding, and it is much more flexible in adapting to unknown parts.This paper describes the entire concept of extending a conventional welding machine with means for image acquisition and position estimation. In addition to this description, the algorithms, the results of an evaluation of position estimation, and a final welding result are presented. 

  6. Blood culture bottles are superior to conventional media for vitreous culture.

    Science.gov (United States)

    Thariya, Patsuda; Yospaiboon, Yosanan; Sinawat, Suthasinee; Sanguansak, Thuss; Bhoomibunchoo, Chavakij; Laovirojjanakul, Wipada

    2016-08-01

    To compare blood culture bottles and conventional media for the vitreous culture in patients with clinically suspected infectious endophthalmitis. Retrospective comparative study at KKU Eye Center, Khon Kaen University. There were 342 patients with clinically suspected infectious endophthalmitis participated in the study. The vitreous specimens were inoculated in both blood culture bottles and on conventional culture media (blood agar, MacConkey agar, chocolate agar, Sabouraud dextrose agar and thioglycolate broth). The number of positive culture yields in both blood culture bottles and conventional media. Positive culture yields in both methods were found in 151 eyes (49.5%). There were 136 of 151 eyes (90.1%) with positive culture in blood culture bottles, whereas 99 of 151 eyes (65.6%) yielded positive cultures in conventional media. These findings were different with a statistical significance (P culture bottles and conventional media improved the yield. Blood culture bottles are superior to conventional media for vitreous culture in clinically suspected infectious endophthalmitis. Vitreous culture using blood culture bottles should be recommended as the primary method for microbiological diagnosis. A combination of both methods further improves the positive culture yield. © 2016 Royal Australian and New Zealand College of Ophthalmologists.

  7. Ultrasound evaluation of normal and abnormal fetuses: comparison of conventional, tissue harmonic, and pulse- inversion harmonic imaging techniques

    International Nuclear Information System (INIS)

    Ryu, Jeong Ah; Kim, Bohyun; Kim, Sooah; Yang, Soon Ha; Choi, Moon Hae; Ahn, Hyeong Sik

    2003-01-01

    To determine the usefulness of tissue harmonic imaging (THI) and pulse-inversion harmonic imaging (PIHI) in the evaluation of normal and abnormal fetuses. Forty-one pregnant women who bore a total of 31 normal and ten abnormal fetuses underwent conventional ultrasonography (CUS), and then THI and PIHI. US images of six organ systems, namely the brain, spine, heart, abdomen, extremities and face were compared between the three techniques in terms of overall conspicuity and the definition of borders and internal structures. For the brain, heart, abdomen and face, overall conspicuity at THI and PIHI was significantly better than at CUS (p < 0.05). There was, though, no significant difference between THI and PIHI. Affected organs in abnormal fetuses were more clearly depicted at THI and PIHI than at CUS. Both THI and PIHI appear to be superior to CUS for the evaluation of normal or abnormal structures, particularly the brain, heart, abdomen and face

  8. Detectability of pulmonary nodules with electronic collimation and conventional antiscatter grid

    International Nuclear Information System (INIS)

    Plenkovich, D.; Plavsic, B.; Robinson, A.E.; Lichtenstein, R.L.

    1989-01-01

    Electronic collimation is a method for rejection of scattered radiation and veiling glare in digital radiography. Digital images of a frozen, unembalmed, human chest phantom with simulated pulmonary nodules were obtained with use of the electronic collimation technique and a conventional 10:1 antiscatter grid. Observers were asked to locate multiple nodules and to record one of three levels of confidence. For each criterion, the total number of correct responses was divided by the total number of nodules to obtain the ordinate of a point. The total number of false-positive answers generated was divided by the number of images to obtain the abscissa of the point. The analysis was repeated for each scatter rejection method and for either the lungs or the mediastinum. The electronic collimation technique has improved the detectability of nodules projected over the mediastinum

  9. Information-efficient spectral imaging sensor

    Science.gov (United States)

    Sweatt, William C.; Gentry, Stephen M.; Boye, Clinton A.; Grotbeck, Carter L.; Stallard, Brian R.; Descour, Michael R.

    2003-01-01

    A programmable optical filter for use in multispectral and hyperspectral imaging. The filter splits the light collected by an optical telescope into two channels for each of the pixels in a row in a scanned image, one channel to handle the positive elements of a spectral basis filter and one for the negative elements of the spectral basis filter. Each channel for each pixel disperses its light into n spectral bins, with the light in each bin being attenuated in accordance with the value of the associated positive or negative element of the spectral basis vector. The spectral basis vector is constructed so that its positive elements emphasize the presence of a target and its negative elements emphasize the presence of the constituents of the background of the imaged scene. The attenuated light in the channels is re-imaged onto separate detectors for each pixel and then the signals from the detectors are combined to give an indication of the presence or not of the target in each pixel of the scanned scene. This system provides for a very efficient optical determination of the presence of the target, as opposed to the very data intensive data manipulations that are required in conventional hyperspectral imaging systems.

  10. Image evaluation of HIV encephalopathy: a multimodal approach using quantitative MR techniques

    Energy Technology Data Exchange (ETDEWEB)

    Prado, Paulo T.C.; Escorsi-Rosset, Sara [University of Sao Paulo, Radiology Section, Internal Medicine Department, Ribeirao Preto School of Medicine, Sao Paulo (Brazil); Cervi, Maria C. [University of Sao Paulo, Department of Pediatrics, Ribeirao Preto School of Medicine, Sao Paulo (Brazil); Santos, Antonio Carlos [University of Sao Paulo, Radiology Section, Internal Medicine Department, Ribeirao Preto School of Medicine, Sao Paulo (Brazil); Hospital das Clinicas da FMRP-USP, Ribeirao Preto, SP (Brazil)

    2011-11-15

    A multimodal approach of the human immunodeficiency virus (HIV) encephalopathy using quantitative magnetic resonance (MR) techniques can demonstrate brain changes not detectable only with conventional magnetic resonance imaging (MRI). The aim of this study was to compare conventional MRI and MR quantitative techniques, such as magnetic resonance spectroscopy (MRS) and relaxometry and to determine whether quantitative techniques are more sensitive than conventional imaging for brain changes caused by HIV infection. We studied prospectively nine HIV positive children (mean age 6 years, from 5 to 8 years old) and nine controls (mean age 7.3 years; from 3 to 10 years), using MRS and relaxometry. Examinations were carried on 1.5-T equipment. HIV-positive patients presented with only minor findings and all control patients had normal conventional MR findings. MRS findings showed an increase in choline to creatine (CHO/CRE) ratios bilaterally in both frontal gray and white matter, in the left parietal white matter, and in total CHO/CRE ratio. In contrast, N-acetylaspartate to creatine (NAA/CRE) ratios did not present with any significant difference between both groups. Relaxometry showed significant bilateral abnormalities, with lengthening of the relaxation time in HIV positive in many regions. Conventional MRI is not sensitive for early brain changes caused by HIV infection. Quantitative techniques such as MRS and relaxometry appear as valuable tools in the diagnosis of these early changes. Therefore, a multimodal quantitative study can be useful in demonstrating and understanding the physiopathology of the disease. (orig.)

  11. Stacker’s Crane Position Fixing Based on Real Time Image Processing and Analysis

    Directory of Open Access Journals (Sweden)

    Kmeid Saad

    2015-06-01

    Full Text Available This study illustrates the usage of stacker cranes and image processing in automated warehouse systems. The aim is to use real time image processing and analysis for a stacker’s crane position fixing in order to use it as a pick-up and delivery system (P/D, to be controlled by a programmable logic controller unit (PLC.

  12. Evaluation of photoshop based image analysis in cytologic diagnosis of pleural fluid in comparison with conventional modalities.

    Science.gov (United States)

    Jafarian, Amir Hossein; Tasbandi, Aida; Mohamadian Roshan, Nema

    2018-04-19

    The aim of this study is to investigate and compare the results of digital image analysis in pleural effusion cytology samples with conventional modalities. In this cross-sectional study, 53 pleural fluid cytology smears from Qaem hospital pathology department, located in Mashhad, Iran were investigated. Prior to digital analysis, all specimens were evaluated by two pathologists and categorized into three groups as: benign, suspicious, and malignant. Using an Olympus microscope and Olympus DP3 digital camera, digital images from cytology slides were captured. Appropriate images (n = 130) were separately imported to Adobe Photoshop CS5 and parameters including area and perimeter, circularity, Gray Value mean, integrated density, and nucleus to cytoplasm area ratio were analyzed. Gray Value mean, nucleus to cytoplasm area ratio, and circularity showed the best sensitivity and specificity rates as well as significant differences between all groups. Also, nucleus area and perimeter showed a significant relation between suspicious and malignant groups with benign group. Whereas, there was no such difference between suspicious and malignant groups. We concluded that digital image analysis is welcomed in the field of research on pleural fluid smears as it can provide quantitative data to apply various comparisons and reduce interobserver variation which could assist pathologists to achieve a more accurate diagnosis. © 2018 Wiley Periodicals, Inc.

  13. Evaluation of positional plagiocephaly: Conventional anthropometric measurement versus laser scanning method.

    Science.gov (United States)

    Nahles, Susanne; Klein, Martin; Yacoub, Anke; Neyer, Julia

    2018-01-01

    The incidence of plagiocephaly has increased in the 25 years since the "Back to Sleep" campaign in 1991 to prevent sudden infant death. Plagiocephaly is not considered to be a pathological condition. It is more of an esthetic impairment and could have potentially negative psychological or psychosocial consequences; therefore, treatment is recommended. The aim of this study is to compare conventional anthropometry and laser scanning - two different measurement methods - as diagnostic instruments for plagiocephaly. The present study also tests the measurement time of both methods and whether one method is easier on the patient than the other. A total of 44 children (21 girls, 23 boys) with a mean age of 8.8 months were involved in the present study. Of all patients, the following parameters were routinely evaluated using a standard protocol with the conventional anthropometric method and the scan method: head circumference, head length, head width, head diagonals, and distances ex-t. Furthermore, the time required to obtain measurements and the behavior of the children during measurement were documented. For statistical analysis, a t-test and a Wilcoxon test were used to analyze differences between the two methods. The results for head circumference showed a mean of 441.5 mm for the anthropometric measurements and 441.6 mm for the scan method, with no significant difference between the two methods. A significant difference was found regarding the head width, head length, diagonals, and distance ex-t. The measurement process using the scan method needed a mean of 579.6 s in contrast to the manual anthropometric method, which required a mean time of 180.5 s. In comparison with the conventional anthropometric method, measurements made with a 3D laser scanner yield inconsistent results. Moreover, the current state of technology of 3D cephalometry has no advantages compared with the conventional anthropometric method. Disadvantages worth mentioning appear to be the

  14. Global positioning method based on polarized light compass system

    Science.gov (United States)

    Liu, Jun; Yang, Jiangtao; Wang, Yubo; Tang, Jun; Shen, Chong

    2018-05-01

    This paper presents a global positioning method based on a polarized light compass system. A main limitation of polarization positioning is the environment such as weak and locally destroyed polarization environments, and the solution to the positioning problem is given in this paper which is polarization image de-noising and segmentation. Therefore, the pulse coupled neural network is employed for enhancing positioning performance. The prominent advantages of the present positioning technique are as follows: (i) compared to the existing position method based on polarized light, better sun tracking accuracy can be achieved and (ii) the robustness and accuracy of positioning under weak and locally destroyed polarization environments, such as cloudy or building shielding, are improved significantly. Finally, some field experiments are given to demonstrate the effectiveness and applicability of the proposed global positioning technique. The experiments have shown that our proposed method outperforms the conventional polarization positioning method, the real time longitude and latitude with accuracy up to 0.0461° and 0.0911°, respectively.

  15. A small animal holding fixture system with positional reproducibility for longitudinal multimodal imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kokuryo, Daisuke; Kimura, Yuichi; Obata, Takayuki; Yamaya, Taiga; Kawamura, Kazunori; Zhang, Ming-Rong; Kanno, Iwao; Aoki, Ichio, E-mail: ukimura@ieee.or [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage, Chiba 263-8555 (Japan)

    2010-07-21

    This study presents a combined small animal holding fixture system, termed a 'bridge capsule', which provides for small animal re-fixation with positional reproducibility. This system comprises separate holding fixtures for the head and lower body and a connecting part to a gas anesthesia system. A mouse is fixed in place by the combination of a head fixture with a movable part made from polyacetal resin, a lower body fixture made from vinyl-silicone and a holder for the legs and tail. For re-fixation, a similar posture could be maintained by the same holding fixtures and a constant distance between the head and lower body fixtures is maintained. Artifacts caused by the bridge capsule system were not observed on magnetic resonance (MRI) and positron emission tomography (PET) images. The average position differences of the spinal column and the iliac body before and after re-fixation for the same modality were approximately 1.1 mm. The difference between the MRI and PET images was approximately 1.8 mm for the lower body fixture after image registration using fiducial markers. This system would be useful for longitudinal, repeated and multimodal imaging experiments requiring similar animal postures.

  16. EPR Imaging at a Few Megahertz Using SQUID Detectors

    Science.gov (United States)

    Hahn, Inseob; Day, Peter; Penanen, Konstantin; Eom, Byeong Ho

    2010-01-01

    An apparatus being developed for electron paramagnetic resonance (EPR) imaging operates in the resonance-frequency range of about 1 to 2 MHz well below the microwave frequencies used in conventional EPR. Until now, in order to obtain sufficient signal-to-noise radios (SNRs) in conventional EPR, it has been necessary to place both detectors and objects to be imaged inside resonant microwave cavities. EPR imaging has much in common with magnetic resonance imaging (MRI), which is described briefly in the immediately preceding article. In EPR imaging as in MRI, one applies a magnetic pulse to make magnetic moments (in this case, of electrons) precess in an applied magnetic field having a known gradient. The magnetic moments precess at a resonance frequency proportional to the strength of the local magnetic field. One detects the decaying resonance-frequency magnetic- field component associated with the precession. Position is encoded by use of the known relationship between the resonance frequency and the position dependence of the magnetic field. EPR imaging has recently been recognized as an important tool for non-invasive, in vivo imaging of free radicals and reduction/oxidization metabolism. However, for in vivo EPR imaging of humans and large animals, the conventional approach is not suitable because (1) it is difficult to design and construct resonant cavities large enough and having the required shapes; (2) motion, including respiration and heartbeat, can alter the resonance frequency; and (3) most microwave energy is absorbed in the first few centimeters of tissue depth, thereby potentially endangering the subject and making it impossible to obtain adequate signal strength for imaging at greater depth. To obtain greater penetration depth, prevent injury to the subject, and avoid the difficulties associated with resonant cavities, it is necessary to use lower resonance frequencies. An additional advantage of using lower resonance frequencies is that one can use

  17. Virtual ultrasound sources in high-resolution ultrasound imaging

    DEFF Research Database (Denmark)

    Nikolov, Svetoslav; Jensen, Jørgen Arendt

    2002-01-01

    beamforming procedure for 3D ultrasound imaging. The position of the virtual source, and the created waveform are investigated with simulation, and with pulse-echo measurements. There is good agreement between the estimated wavefront and the theoretically tted one. Several examples of the use of virtual...... source elements are considered. Using SAF on data acquired for a conventional linear array imaging improves the penetration depth for the particular imaging situation from 80 to 110 mm. The independent use of virtual source elements in the elevation plane decreases the respective size of the point spread...

  18. "It's all about acceptance": A qualitative study exploring a model of positive body image for people with spinal cord injury.

    Science.gov (United States)

    Bailey, K Alysse; Gammage, Kimberley L; van Ingen, Cathy; Ditor, David S

    2015-09-01

    Using modified constructivist grounded theory, the purpose of the present study was to explore positive body image experiences in people with spinal cord injury. Nine participants (five women, four men) varying in age (21-63 years), type of injury (C3-T7; complete and incomplete), and years post-injury (4-36 years) were recruited. The following main categories were found: body acceptance, body appreciation and gratitude, social support, functional gains, independence, media literacy, broadly conceptualizing beauty, inner positivity influencing outer demeanour, finding others who have a positive body image, unconditional acceptance from others, religion/spirituality, listening to and taking care of the body, managing secondary complications, minimizing pain, and respect. Interestingly, there was consistency in positive body image characteristics reported in this study with those found in previous research, demonstrating universality of positive body image. However, unique characteristics (e.g., resilience, functional gains, independence) were also reported demonstrating the importance of exploring positive body image in diverse groups. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. The value of endorectal MR imaging to predict positive biopsies in clinically intermediate-risk prostate cancer patients

    International Nuclear Information System (INIS)

    Vilanova, J.C.; Barcelo, J.; Comet, J.; Capdevila, A.; Dolz, J.L.; Huguet, M.; Aldoma, J.; Delgado, E.; Barcelo, C.

    2001-01-01

    The aim of this study was to assess the effectiveness of endorectal MR imaging in predicting the positive biopsy results in patients with clinically intermediate risk for prostate cancer. We performed a prospective endorectal MR imaging study with 81 patients at intermediate risk to detect prostate cancer between January 1997 and December 1998. Intermediate risk was defined as: prostatic specific antigen (PSA) levels between 4 and 10 ng/ml or PSA levels in the range of 10-20 ng/ml but negative digital rectal examination (DRE) or PSA levels progressively higher (0.75 ng/ml year -1 ). A transrectal sextant biopsy was performed after the endorectal MR exam, and also of the area of suspicion detected by MR imaging. The accuracies were measured, both singly for MR imaging and combined for PSA level and DRE, by calculating the area index of the receiver operating characteristics (ROC) curve. Cancer was detected in 23 patients (28 %). Overall sensitivity and specificity of endorectal MRI was 70 and 76 %, respectively. Accuracy was 71 % estimated from the area under the ROC curve for the total patient group and 84 % for the group of patients with PSA level between 10-20 ng/ml. Positive biopsy rate (PBR) was 63 % for the group with PSA 10-20 ng/ml and a positive MR imaging, and 15 % with a negative MR exam. The PBR was 43 % for the group with PSA 4-10 ng/ml and a positive MR study, and 13 % with a negative MR imaging examination. We would have avoided 63 % of negative biopsies, while missing 30 % of cancers for the total group of patients. Endorectal MR imaging was not a sufficient predictor of positive biopsies for patients clinically at intermediate risk for prostate cancer. Although we should not avoid performing systematic biopsies in patients with endorectal MR imaging negative results, as it will miss a significant number of cancers, selected patients with a PSA levels between 10-20 ng/ml or clinical-biopsy disagreement might benefit from endorectal MR imaging. (orig.)

  20. The value of endorectal MR imaging to predict positive biopsies in clinically intermediate-risk prostate cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Vilanova, J.C.; Barcelo, J. [Ressonancia Girona, Clinica Girona, Girona (Spain); Comet, J. [Dept. of Urology, Univ. Hospital of Girona (Spain); Capdevila, A.; Dolz, J.L.; Huguet, M.; Aldoma, J.; Delgado, E. [Centre Diagnostic Pedralbes, Cetir Grup Medic, Barcelona (Spain); Barcelo, C. [Dept. of Computer Science and Applied Mathematics, University of Girona (Spain)

    2001-02-01

    The aim of this study was to assess the effectiveness of endorectal MR imaging in predicting the positive biopsy results in patients with clinically intermediate risk for prostate cancer. We performed a prospective endorectal MR imaging study with 81 patients at intermediate risk to detect prostate cancer between January 1997 and December 1998. Intermediate risk was defined as: prostatic specific antigen (PSA) levels between 4 and 10 ng/ml or PSA levels in the range of 10-20 ng/ml but negative digital rectal examination (DRE) or PSA levels progressively higher (0.75 ng/ml year{sup -1}). A transrectal sextant biopsy was performed after the endorectal MR exam, and also of the area of suspicion detected by MR imaging. The accuracies were measured, both singly for MR imaging and combined for PSA level and DRE, by calculating the area index of the receiver operating characteristics (ROC) curve. Cancer was detected in 23 patients (28 %). Overall sensitivity and specificity of endorectal MRI was 70 and 76 %, respectively. Accuracy was 71 % estimated from the area under the ROC curve for the total patient group and 84 % for the group of patients with PSA level between 10-20 ng/ml. Positive biopsy rate (PBR) was 63 % for the group with PSA 10-20 ng/ml and a positive MR imaging, and 15 % with a negative MR exam. The PBR was 43 % for the group with PSA 4-10 ng/ml and a positive MR study, and 13 % with a negative MR imaging examination. We would have avoided 63 % of negative biopsies, while missing 30 % of cancers for the total group of patients. Endorectal MR imaging was not a sufficient predictor of positive biopsies for patients clinically at intermediate risk for prostate cancer. Although we should not avoid performing systematic biopsies in patients with endorectal MR imaging negative results, as it will miss a significant number of cancers, selected patients with a PSA levels between 10-20 ng/ml or clinical-biopsy disagreement might benefit from endorectal MR imaging

  1. SU-E-J-134: An Augmented-Reality Optical Imaging System for Accurate Breast Positioning During Radiotherapy

    International Nuclear Information System (INIS)

    Nazareth, D; Malhotra, H; French, S; Hoffmann, K; Merrow, C

    2014-01-01

    Purpose: Breast radiotherapy, particularly electronic compensation, may involve large dose gradients and difficult patient positioning problems. We have developed a simple self-calibrating augmented-reality system, which assists in accurately and reproducibly positioning the patient, by displaying her live image from a single camera superimposed on the correct perspective projection of her 3D CT data. Our method requires only a standard digital camera capable of live-view mode, installed in the treatment suite at an approximately-known orientation and position (rotation R; translation T). Methods: A 10-sphere calibration jig was constructed and CT imaged to provide a 3D model. The (R,T) relating the camera to the CT coordinate system were determined by acquiring a photograph of the jig and optimizing an objective function, which compares the true image points to points calculated with a given candidate R and T geometry. Using this geometric information, 3D CT patient data, viewed from the camera's perspective, is plotted using a Matlab routine. This image data is superimposed onto the real-time patient image, acquired by the camera, and displayed using standard live-view software. This enables the therapists to view both the patient's current and desired positions, and guide the patient into assuming the correct position. The method was evaluated using an in-house developed bolus-like breast phantom, mounted on a supporting platform, which could be tilted at various angles to simulate treatment-like geometries. Results: Our system allowed breast phantom alignment, with an accuracy of about 0.5 cm and 1 ± 0.5 degree. Better resolution could be possible using a camera with higher-zoom capabilities. Conclusion: We have developed an augmented-reality system, which combines a perspective projection of a CT image with a patient's real-time optical image. This system has the potential to improve patient setup accuracy during breast radiotherapy, and could possibly be

  2. SU-E-J-134: An Augmented-Reality Optical Imaging System for Accurate Breast Positioning During Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Nazareth, D; Malhotra, H; French, S [Roswell Park Cancer Institute, Buffalo, NY (United States); Hoffmann, K [Neurosurgery at SUNY at Buffalo, Buffalo, NY (United States); Merrow, C [Bassett Healthcare, Oneonta, NY (United States)

    2014-06-01

    Purpose: Breast radiotherapy, particularly electronic compensation, may involve large dose gradients and difficult patient positioning problems. We have developed a simple self-calibrating augmented-reality system, which assists in accurately and reproducibly positioning the patient, by displaying her live image from a single camera superimposed on the correct perspective projection of her 3D CT data. Our method requires only a standard digital camera capable of live-view mode, installed in the treatment suite at an approximately-known orientation and position (rotation R; translation T). Methods: A 10-sphere calibration jig was constructed and CT imaged to provide a 3D model. The (R,T) relating the camera to the CT coordinate system were determined by acquiring a photograph of the jig and optimizing an objective function, which compares the true image points to points calculated with a given candidate R and T geometry. Using this geometric information, 3D CT patient data, viewed from the camera's perspective, is plotted using a Matlab routine. This image data is superimposed onto the real-time patient image, acquired by the camera, and displayed using standard live-view software. This enables the therapists to view both the patient's current and desired positions, and guide the patient into assuming the correct position. The method was evaluated using an in-house developed bolus-like breast phantom, mounted on a supporting platform, which could be tilted at various angles to simulate treatment-like geometries. Results: Our system allowed breast phantom alignment, with an accuracy of about 0.5 cm and 1 ± 0.5 degree. Better resolution could be possible using a camera with higher-zoom capabilities. Conclusion: We have developed an augmented-reality system, which combines a perspective projection of a CT image with a patient's real-time optical image. This system has the potential to improve patient setup accuracy during breast radiotherapy, and could

  3. Added value of integrated circuit detector in head CT: objective and subjective image quality in comparison to conventional detector design.

    Science.gov (United States)

    Korn, Andreas; Bender, Benjamin; Spira, Daniel; Schabel, Christoph; Bhadelia, Rafeeque; Claussen, Claus; Ernemann, Ulrike; Brodoefel, Harald

    2014-12-01

    A new computed tomography (CT) detector with integrated electric components and shorter conducting pathways has recently been introduced to decrease system inherent electronic noise. The purpose of this study was to assess the potential benefit of such integrated circuit detector (ICD) in head CT by comparing objective and subjective image quality in low-dose examinations with a conventional detector design. Using a conventional detector, reduced-dose noncontrast head CT (255 mAs; effective dose, 1.7 mSv) was performed in 25 consecutive patients. Following transition to ICD, 25 consecutive patients were scanned using identical imaging parameters. Images in both groups were reconstructed with iterative reconstruction (IR) and filtered back projection (FBP) and assessed in terms of quantitative and qualitative image quality. Acquisition of head CT using ICD increased signal-to-noise ratio of gray and white matter by 14% (10.0 ± 1.6 vs. 11.4 ± 2.5; P = .02) and 17% (8.2 ± 0.8 vs. 9.6 ± 1.5; P = .000). The associated improvement in contrast-to-noise ratio was 12% (2.0 ± 0.5 vs. 2.2 ± 0.6; P = .121). In addition, there was a 51% increase in objective image sharpness (582 ± 85 vs. 884.5 ± 191; change in HU/Pixel; P < .000). Compared to standard acquisitions, subjective grading of noise and overall image quality scores were significantly improved with ICD (2.1 ± 0.3 vs. 1.6 ± 0.3; P < .000; 2.0 ± 0.5 vs. 1.6 ± 0.3; P = .001). Moreover, streak artifacts in the posterior fossa were substantially reduced (2.3 ± 0.7 vs. 1.7 ± 0.5; P = .004). At the same radiation level, acquisition of head CT with ICD achieves superior objective and subjective image quality and provides potential for significant dose reduction. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.

  4. Reinforcing the role of the conventional C-arm - a novel method for simplified distal interlocking

    Directory of Open Access Journals (Sweden)

    Windolf Markus

    2012-01-01

    Full Text Available Abstract Background The common practice for insertion of distal locking screws of intramedullary nails is a freehand technique under fluoroscopic control. The process is technically demanding, time-consuming and afflicted to considerable radiation exposure of the patient and the surgical personnel. A new concept is introduced utilizing information from within conventional radiographic images to help accurately guide the surgeon to place the interlocking bolt into the interlocking hole. The newly developed technique was compared to conventional freehand in an operating room (OR like setting on human cadaveric lower legs in terms of operating time and radiation exposure. Methods The proposed concept (guided freehand, generally based on the freehand gold standard, additionally guides the surgeon by means of visible landmarks projected into the C-arm image. A computer program plans the correct drilling trajectory by processing the lens-shaped hole projections of the interlocking holes from a single image. Holes can be drilled by visually aligning the drill to the planned trajectory. Besides a conventional C-arm, no additional tracking or navigation equipment is required. Ten fresh frozen human below-knee specimens were instrumented with an Expert Tibial Nail (Synthes GmbH, Switzerland. The implants were distally locked by performing the newly proposed technique as well as the conventional freehand technique on each specimen. An orthopedic resident surgeon inserted four distal screws per procedure. Operating time, number of images and radiation time were recorded and statistically compared between interlocking techniques using non-parametric tests. Results A 58% reduction in number of taken images per screw was found for the guided freehand technique (7.4 ± 3.4 (mean ± SD compared to the freehand technique (17.6 ± 10.3 (p p = 0.001. Operating time per screw (from first shot to screw tightened was on average 22% reduced by guided freehand (p = 0

  5. Environmental impact of non-conventional energy sources

    International Nuclear Information System (INIS)

    Abbasi, S.A.; Abbasi, Naseema; Nipaney, P.C.; Ramasamy, E.V.

    1995-01-01

    Whereas the global attention has always been focused on the adverse environmental impacts of conventional energy sources, only a few studies have been conducted on the clean environment image of the non-conventional energy sources, particularly the renewable ones. The question whether the non-conventional sources are really as benign as they are made out to be is addressed in the present paper in the background of a classical paradigm developed by Lovin which had postulated the hard (malignant) and soft (benign) energy concepts in the first place. It then assesses the likely environmental impacts of several major non-conventional energy sources and comes up with the note of caution that in many cases the adverse impacts may not be insubstantial; indeed in some cases they can be as strongly negative as the impacts of the conventional energy sources. (author). 31 refs

  6. Selection of optimal pulse sequences for conventional and dynamic MR imaging with Gd-DTPA; A fundamental study

    Energy Technology Data Exchange (ETDEWEB)

    Maeda, Miho; Kita, Keisuke; Maeda, Masayuki (Wakayama Medical Coll. (Japan)) (and others)

    1989-11-01

    Gadolinium-DTPA (Gd-DTPA) enhances contrast between tissues in magnetic resonance (MR) imaging. The enhancement of tissues depends partly upon the pulse sequences, and the optimal pulse sequence is also influenced by the tissue cncentration of Gd-DTPA. We prepared phantoms of 25% albumin solutions with various concentrations of Gd-DTPA, and imaged them using various pulse sequences with 1.5-T MR system. We also performed MR imaging of 16 patients with tumors (10 brain tumors and 6 hepatic tumors) before and after intravenous administration of Gd-DTPA (0.1 mmol/kg); 6 patients with hepatic tumors underwent dynamic MR imaging during suspended respiration. We made a theoretical equation to calculate the concentration of Gd-DTPA and estimated its tissue concentration in tumors at 0{approx}0.2 mmol/kg. Within these tissue concentrations, the enhancement-to-noise (E/N) ratio was larger in FISP (flip angle of 90deg, TR pf 300 msec, minimal TE) and SE (TR of 400 msec, minimal TE) sequences than in other sequences observed. These sequences may be preferable for conventional enhanced-MRI. Among the pulse sequences with TR of less than 100 msec, FISP (flip angle of 90deg, TR of less than 100 msec, minimal TE) had the largest E/N ratio; which may be useful for dynamic MRI during suspended respiration. The importance of selecting the optimal pulse sequences according to the imaging modality used will be discussed. (author).

  7. Comparative cardiac imaging

    International Nuclear Information System (INIS)

    Brundage, B.H.

    1990-01-01

    This book is designed to compare all major cardiac imaging techniques. All major imaging techniques - including conventional angiography, digital angiography, echocardiography and Doppler imaging, conventional radioisotope techniques, computed tomography, and magnetic resonance imaging - are covered in this text as they apply to the major cardiovascular disorders. There is brief coverage of positron emission tomography and an extensive presentation of ultrafast computed tomography

  8. Automatic image fusion of real-time ultrasound with computed tomography images: a prospective comparison between two auto-registration methods.

    Science.gov (United States)

    Cha, Dong Ik; Lee, Min Woo; Kim, Ah Yeong; Kang, Tae Wook; Oh, Young-Taek; Jeong, Ja-Yeon; Chang, Jung-Woo; Ryu, Jiwon; Lee, Kyong Joon; Kim, Jaeil; Bang, Won-Chul; Shin, Dong Kuk; Choi, Sung Jin; Koh, Dalkwon; Seo, Bong Koo; Kim, Kyunga

    2017-11-01

    Background A major drawback of conventional manual image fusion is that the process may be complex, especially for less-experienced operators. Recently, two automatic image fusion techniques called Positioning and Sweeping auto-registration have been developed. Purpose To compare the accuracy and required time for image fusion of real-time ultrasonography (US) and computed tomography (CT) images between Positioning and Sweeping auto-registration. Material and Methods Eighteen consecutive patients referred for planning US for radiofrequency ablation or biopsy for focal hepatic lesions were enrolled. Image fusion using both auto-registration methods was performed for each patient. Registration error, time required for image fusion, and number of point locks used were compared using the Wilcoxon signed rank test. Results Image fusion was successful in all patients. Positioning auto-registration was significantly faster than Sweeping auto-registration for both initial (median, 11 s [range, 3-16 s] vs. 32 s [range, 21-38 s]; P auto-registration was significantly higher for initial image fusion (median, 38.8 mm [range, 16.0-84.6 mm] vs. 18.2 mm [6.7-73.4 mm]; P = 0.029), but not for complete image fusion (median, 4.75 mm [range, 1.7-9.9 mm] vs. 5.8 mm [range, 2.0-13.0 mm]; P = 0.338]. Number of point locks required to refine the initially fused images was significantly higher with Positioning auto-registration (median, 2 [range, 2-3] vs. 1 [range, 1-2]; P = 0.012]. Conclusion Positioning auto-registration offers faster image fusion between real-time US and pre-procedural CT images than Sweeping auto-registration. The final registration error is similar between the two methods.

  9. Development of Methods for Obtaining Position Image and Chemical Binding Information from Flow Experiments of Porous Media

    Energy Technology Data Exchange (ETDEWEB)

    Haugan, Are

    1998-12-01

    Existing oil reservoirs might be more fully exploited if the properties of the flow of oil and water in porous media were better known. In laboratory experiments it is important to collect as much information as possible to make a descriptive model of the system, including position imaging and chemical binding information. This thesis develops nuclear methods for obtaining position image and chemical binding information from flow experiments of porous media. A combined positron emission tomography and single photon emission computed tomography system to obtain position images, and a time-differential perturbed angular correlation system to obtain chemical binding information, have been built and thoroughly tested. 68 refs., 123 figs., 14 tabs.

  10. Evaluation by entrained imaging of the positioning precision and repositioning in fractionated stereotaxic radiotherapy

    International Nuclear Information System (INIS)

    Brunet, G.; Delpon, G.; Bardet, E.; Bourdin, S.; Gaudaire, S.; Munos, C.; Preuvel, P.; Mahe, M.A.; Lisbona, A.

    2006-01-01

    The differences of daily positioning have been quantified and the precision of this king of contention has been evaluated. The buccal support improves the positioning precision. The daily use of the entrained image is feasible in routine and allows a measurable improvement of the treatment precision. (N.C.)

  11. BrachyView: Combining LDR seed positions with transrectal ultrasound imaging in a prostate gel phantom.

    Science.gov (United States)

    Alnaghy, S; Cutajar, D L; Bucci, J A; Enari, K; Safavi-Naeini, M; Favoino, M; Tartaglia, M; Carriero, F; Jakubek, J; Pospisil, S; Lerch, M; Rosenfeld, A B; Petasecca, M

    2017-02-01

    BrachyView is a novel in-body imaging system which aims to provide LDR brachytherapy seeds position reconstruction within the prostate in real-time. The first prototype is presented in this study: the probe consists of a gamma camera featuring three single cone pinhole collimators embedded in a tungsten tube, above three, high resolution pixelated detectors (Timepix). The prostate was imaged with a TRUS system using a sagittal crystal with a 2.5mm slice thickness. Eleven needles containing a total of thirty 0.508U 125 I seeds were implanted under ultrasound guidance. A CT scan was used to localise the seed positions, as well as provide a reference when performing the image co-registration between the BrachyView coordinate system and the TRUS coordinate system. An in-house visualisation software interface was developed to provide a quantitative 3D reconstructed prostate based on the TRUS images and co-registered with the LDR seeds in situ. A rigid body image registration was performed between the BrachyView and TRUS systems, with the BrachyView and CT-derived source locations compared. The reconstructed seed positions determined by the BrachyView probe showed a maximum discrepancy of 1.78mm, with 75% of the seeds reconstructed within 1mm of their nominal location. An accurate co-registration between the BrachyView and TRUS coordinate system was established. The BrachyView system has shown its ability to reconstruct all implanted LDR seeds within a tissue equivalent prostate gel phantom, providing both anatomical and seed position information in a single interface. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  12. Diagnostic performance of conventional diffusion weighted imaging and diffusion tensor imaging for the liver fibrosis and inflammation

    International Nuclear Information System (INIS)

    Tosun, Mesude; Inan, Nagihan; Sarisoy, Hasan Tahsin; Akansel, Gur; Gumustas, Sevtap; Gürbüz, Yeşim; Demirci, Ali

    2013-01-01

    Objective: To evaluate the diagnostic accuracy of liver apparent diffusion coefficient (ADC) measured with conventional diffusion-weighted imaging (CDI) and diffusion tensor imaging (DTI) for the diagnosis of liver fibrosis and inflammation. Materials and methods: Thirty-seven patients with histologic diagnosis of chronic viral hepatitis and 34 healthy volunteers were included in this prospective study. All patients and healthy volunteers were examined by 3 T MRI. CDI and DTI were performed using a breath-hold single-shot echo-planar spin echo sequence with b factors of 0 and 1000 s/mm 2 . ADCs were obtained with CDI and DTI. Histopathologically, fibrosis of the liver parenchyma was classified with the use of a 5-point scale (0–4) and inflammation was classified with use of a 4-point scale (0–3) in accordance with the METAVIR score. Quantitatively, signal intensity and the ADCs of the liver parenchyma were compared between patients stratified by fibrosis stage and inflammation grade. Results: With a b factor of 1000 s/mm 2 , the signal intensity of the cirrhotic livers was significantly higher than those of the normal volunteers. In addition, ADCs reconstructed from CDI and DTI of the patients were significantly lower than those of the normal volunteers. Liver ADC values inversely correlated with fibrosis and inflammation but there was only statistically significant for inflammatory grading. CDI performed better than DTI for the diagnosis of fibrosis and inflammation. Conclusion: ADC values measured with CDI and DTI may help in the detection of liver fibrosis. They may also give contributory to the inflammatory grading, particularly in distinguishing high from low grade

  13. Diagnostic performance of conventional diffusion weighted imaging and diffusion tensor imaging for the liver fibrosis and inflammation

    Energy Technology Data Exchange (ETDEWEB)

    Tosun, Mesude, E-mail: mesude.tosun@kocaeli.edu.tr [Department of Radiology, School of Medicine, University of Kocaeli (Turkey); Inan, Nagihan, E-mail: inannagihan@ekolay.net [Department of Radiology, School of Medicine, University of Kocaeli (Turkey); Sarisoy, Hasan Tahsin, E-mail: htssarisoy@yahoo.com [Department of Radiology, School of Medicine, University of Kocaeli (Turkey); Akansel, Gur, E-mail: gakansel@gmail.com [Department of Radiology, School of Medicine, University of Kocaeli (Turkey); Gumustas, Sevtap, E-mail: svtgumustas@hotmail.com [Department of Radiology, School of Medicine, University of Kocaeli (Turkey); Gürbüz, Yeşim, E-mail: yesimgurbuz2002@yahoo.com [Department of Pathology, School of Medicine, University of Kocaeli (Turkey); Demirci, Ali, E-mail: alidemirci@kocaeli.edu.tr [Department of Radiology, School of Medicine, University of Kocaeli (Turkey)

    2013-02-15

    Objective: To evaluate the diagnostic accuracy of liver apparent diffusion coefficient (ADC) measured with conventional diffusion-weighted imaging (CDI) and diffusion tensor imaging (DTI) for the diagnosis of liver fibrosis and inflammation. Materials and methods: Thirty-seven patients with histologic diagnosis of chronic viral hepatitis and 34 healthy volunteers were included in this prospective study. All patients and healthy volunteers were examined by 3 T MRI. CDI and DTI were performed using a breath-hold single-shot echo-planar spin echo sequence with b factors of 0 and 1000 s/mm{sup 2}. ADCs were obtained with CDI and DTI. Histopathologically, fibrosis of the liver parenchyma was classified with the use of a 5-point scale (0–4) and inflammation was classified with use of a 4-point scale (0–3) in accordance with the METAVIR score. Quantitatively, signal intensity and the ADCs of the liver parenchyma were compared between patients stratified by fibrosis stage and inflammation grade. Results: With a b factor of 1000 s/mm{sup 2}, the signal intensity of the cirrhotic livers was significantly higher than those of the normal volunteers. In addition, ADCs reconstructed from CDI and DTI of the patients were significantly lower than those of the normal volunteers. Liver ADC values inversely correlated with fibrosis and inflammation but there was only statistically significant for inflammatory grading. CDI performed better than DTI for the diagnosis of fibrosis and inflammation. Conclusion: ADC values measured with CDI and DTI may help in the detection of liver fibrosis. They may also give contributory to the inflammatory grading, particularly in distinguishing high from low grade.

  14. Mobile positioning and tracking from conventional to cooperative techniques

    CERN Document Server

    Frattasi, Simone

    2017-01-01

    Current trends in mobile services envisage location-based networking as a major strong stimulator for the development of novel solutions for obtaining positioning information in wireless networks. This book discusses mobile positioning solutions applied on top of current wireless communication networks. Moreover, it introduces advanced and novel topics such as localization in heterogeneous and cooperative scenarios. In this fully updated second edition, the authors summarize recent developments in mobile positioning and tracking. Compared with the previous version, the new edition introduces more advanced topics, providing the bridge between research and industry. It works as an important reference and provides good foundations for new researchers.

  15. Image-guided positioning and tracking.

    Science.gov (United States)

    Ruan, Dan; Kupelian, Patrick; Low, Daniel A

    2011-01-01

    Radiation therapy aims at maximizing tumor control while minimizing normal tissue complication. The introduction of stereotactic treatment explores the volume effect and achieves dose escalation to tumor target with small margins. The use of ablative irradiation dose and sharp dose gradients requires accurate tumor definition and alignment between patient and treatment geometry. Patient geometry variation during treatment may significantly compromise the conformality of delivered dose and must be managed properly. Setup error and interfraction/intrafraction motion are incorporated in the target definition process by expanding the clinical target volume to planning target volume, whereas the alignment between patient and treatment geometry is obtained with an adaptive control process, by taking immediate actions in response to closely monitored patient geometry. This article focuses on the monitoring and adaptive response aspect of the problem. The term "image" in "image guidance" will be used in a most general sense, to be inclusive of some important point-based monitoring systems that can be considered as degenerate cases of imaging. Image-guided motion adaptive control, as a comprehensive system, involves a hierarchy of decisions, each of which balances simplicity versus flexibility and accuracy versus robustness. Patient specifics and machine specifics at the treatment facility also need to be incorporated into the decision-making process. Identifying operation bottlenecks from a system perspective and making informed compromises are crucial in the proper selection of image-guidance modality, the motion management mechanism, and the respective operation modes. Not intended as an exhaustive exposition, this article focuses on discussing the major issues and development principles for image-guided motion management systems. We hope these information and methodologies will facilitate conscientious practitioners to adopt image-guided motion management systems

  16. Comparison of conventional and cadmium-zinc-telluride single-photon emission computed tomography for analysis of thallium-201 myocardial perfusion imaging: an exploratory study in normal databases for different ethnicities.

    Science.gov (United States)

    Ishihara, Masaru; Onoguchi, Masahisa; Taniguchi, Yasuyo; Shibutani, Takayuki

    2017-12-01

    The aim of this study was to clarify the differences in thallium-201-chloride (thallium-201) myocardial perfusion imaging (MPI) scans evaluated by conventional anger-type single-photon emission computed tomography (conventional SPECT) versus cadmium-zinc-telluride SPECT (CZT SPECT) imaging in normal databases for different ethnic groups. MPI scans from 81 consecutive Japanese patients were examined using conventional SPECT and CZT SPECT and analyzed with the pre-installed quantitative perfusion SPECT (QPS) software. We compared the summed stress score (SSS), summed rest score (SRS), and summed difference score (SDS) for the two SPECT devices. For a normal MPI reference, we usually use Japanese databases for MPI created by the Japanese Society of Nuclear Medicine, which can be used with conventional SPECT but not with CZT SPECT. In this study, we used new Japanese normal databases constructed in our institution to compare conventional and CZT SPECT. Compared with conventional SPECT, CZT SPECT showed lower SSS (p < 0.001), SRS (p = 0.001), and SDS (p = 0.189) using the pre-installed SPECT database. In contrast, CZT SPECT showed no significant difference from conventional SPECT in QPS analysis using the normal databases from our institution. Myocardial perfusion analyses by CZT SPECT should be evaluated using normal databases based on the ethnic group being evaluated.

  17. Rates of Amyloid Imaging Positivity in Patients With Primary Progressive Aphasia

    Science.gov (United States)

    Santos-Santos, Miguel A.; Rabinovici, Gil D.; Iaccarino, Leonardo; Ayakta, Nagehan; Tammewar, Gautam; Lobach, Iryna; Henry, Maya L.; Hubbard, Isabel; Mandelli, Maria Luisa; Spinelli, Edoardo; Miller, Zachary A.; Pressman, Peter S.; O’Neil, James P.; Ghosh, Pia; Lazaris, Andreas; Meyer, Marita; Watson, Christa; Yoon, Soo Jin; Rosen, Howard J.; Grinberg, Lea; Seeley, William W.; Miller, Bruce L.; Jagust, William J.; Gorno-Tempini, Maria Luisa

    2018-01-01

    IMPORTANCE The ability to predict the pathology underlying different neurodegenerative syndromes is of critical importance owing to the advent of molecule-specific therapies. OBJECTIVE To determine the rates of positron emission tomography (PET) amyloid positivity in the main clinical variants of primary progressive aphasia (PPA). DESIGN, SETTING, AND PARTICIPANTS This prospective clinical-pathologic case series was conducted at a tertiary research clinic specialized in cognitive disorders. Patients were evaluated as part of a prospective, longitudinal research study between January 2002 and December 2015. Inclusion criteria included clinical diagnosis of PPA; availability of complete speech, language, and cognitive testing; magnetic resonance imaging performed within 6 months of the cognitive evaluation; and PET carbon 11–labeled Pittsburgh Compound-B or florbetapir F 18 brain scan results. Of 109 patients referred for evaluation of language symptoms who underwent amyloid brain imaging, 3 were excluded because of incomplete language evaluations, 5 for absence of significant aphasia, and 12 for presenting with significant initial symptoms outside of the language domain, leaving a cohort of 89 patients with PPA. MAIN OUTCOMES AND MEASURES Clinical, cognitive, neuroimaging, and pathology results. RESULTS Twenty-eight cases were classified as imaging-supported semantic variant PPA (11 women [39.3%]; mean [SD] age, 64 [7] years), 31 nonfluent/agrammatic variant PPA (22 women [71.0%]; mean [SD] age, 68 [7] years), 26 logopenic variant PPA (17 women [65.4%]; mean [SD] age, 63 [8] years), and 4 mixed PPA cases. Twenty-four of 28 patients with semantic variant PPA (86%) and 28 of 31 patients with nonfluent/agrammatic variant PPA (90%) had negative amyloid PET scan results, while 25 of 26 patients with logopenic variant PPA (96%) and 3 of 4 mixed PPA cases (75%) had positive scan results. The amyloid positive semantic variant PPA and nonfluent/agrammatic variant PPA cases

  18. Method and apparatus for animal positioning in imaging systems

    Science.gov (United States)

    Hadjioannou, Arion-Xenofon; Stout, David B.; Silverman, Robert W.

    2013-01-01

    An apparatus for imaging an animal includes a first mounting surface, a bed sized to support the animal and releasably secured to or integral with the first mounting surface. The apparatus also includes a plurality of straps, each having a first end in a fixed position relative to the bed and a second end for tightening around a limb of the animal. A method for in-vivo imaging of an animal includes providing an animal that has limbs, providing a first mounting surface, and providing a bed removably secured to or integral with the mounting surface and sized to support the animal as well as being coupled to a plurality of straps. The method also includes placing the animal on the bed between the plurality of straps and tightening at least two of the plurality of straps around at least two of the limbs such that the animal is substantially secured in place relative to the bed.

  19. Single exposure simultaneous acquisition of digital and conventional radiographs utilizing unaltered dose

    International Nuclear Information System (INIS)

    Oestmann, J.W.; Greene, R.

    1988-01-01

    We describe the simultaneous acquisition of digital and conventional radiographs with a single standard radiographic exposure. A digitizable storage phosphor (ST Imaging Plate, Fuji) is sandwiched into a radiographic cassette (X-Omatic, Kodak) behind a conventional radiographic film-screen combination (Lanex medium screens, OC film, Kodak). The barium fluorohalide storage phosphor is digitized with a helium-neon laser scanner (TCR 201, Toshiba), and the conventional radiograph is processed in the standard fashion (M7B, Kodak). The storage phosphor is exposed by the 'wasted' radiation normally exiting the back of the film-screen combination (32% of the cassette entrance dose at 141 kVp). At a standard exposure (6.3 mAs), the conventional radiograph is of unaltered quality, and the digital image appears to have an adequate signal-to-noise ratio for chest studies despite the lower exposure dose. This technique produces twin images of identical spatial and temporal registration and avoids the added radiation exposure normally required to carry out comparative studies. (orig.)

  20. Mixing of multi-modal images for conformational radiotherapy: application to patient re positioning

    International Nuclear Information System (INIS)

    Vassal, P.

    1998-01-01

    This study shows a procedure of patient re positioning by comparative evaluation between the position of the patient and the theoretical expected position of the patient; the stagger between the two information gives the error of installation in translation and rotation. A correction is calculated and applied to the treatment environment (position and orientation of the patient, position and orientation of the irradiation source). The control system allows to determine the precise position of the tumor volume. The echography allows to determine the position of an organ.The surface captor is used to localize the tumors of the face or of the brain, with the respect to the face, the acquisition and the treatment of information take only few minutes. The X rays imager is applied for the localization of bones structures. (N.C.)

  1. Comparison of conventional and novel PET tracers for imaging mesothelioma in nude mice with subcutaneous and intrapleural xenografts

    Energy Technology Data Exchange (ETDEWEB)

    Tsuji, Atsushi B.; Sogawa, Chizuru; Sugyo, Aya [Diagnostic Imaging Group, Molecular Imaging Center, National Institute of Radiological Sciences, Chiba 263-8555 (Japan); Sudo, Hitomi [Diagnostic Imaging Group, Molecular Imaging Center, National Institute of Radiological Sciences, Chiba 263-8555 (Japan); Department of Pathology and Oncology, Juntendo University School of Medicine, Tokyo, 113-8421 (Japan); Toyohara, Jun [Division of Clinical Neuroscience, Chiba University Center for Forensic Mental Health, 206-8670 (Japan); Koizumi, Mitsuru [Diagnostic Imaging Group, Molecular Imaging Center, National Institute of Radiological Sciences, Chiba 263-8555 (Japan); Abe, Masaaki; Hino, Okio [Department of Pathology and Oncology, Juntendo University School of Medicine, Tokyo, 113-8421 (Japan); Harada, Yoshi-nobu; Furukawa, Takako [Diagnostic Imaging Group, Molecular Imaging Center, National Institute of Radiological Sciences, Chiba 263-8555 (Japan); Suzuki, Kazutoshi [Molecular Probe Group, Molecular Imaging Center, National Institute of Radiological Sciences, Chiba 263-8555 (Japan); Saga, Tsuneo [Diagnostic Imaging Group, Molecular Imaging Center, National Institute of Radiological Sciences, Chiba 263-8555 (Japan)], E-mail: saga@nirs.go.jp

    2009-05-15

    Introduction: Malignant mesothelioma is a highly aggressive tumor originating in the pleura, peritoneum and pericardium, and the prognosis of patients undergoing current treatment remains poor. To develop new therapies, it is important to have a noninvasive imaging system for evaluating the efficacy of such prospective treatments. We have established clinically relevant mouse models and evaluated conventional and novel positron emission tomography (PET) tracers. Methods: Epithelioid and sarcomatoid mesothelioma cells were inoculated subcutaneously and intrapleurally into nude mice. Biodistribution and PET imaging studies were conducted by injecting [{sup 18}F]fluoro-2-deoxy-D-glucose (FDG), 3'-[{sup 18}F]fluoro-3'-doxythymidine (FLT) or 4'-methyl-[{sup 11}C]thiothymidine (S-dThd) into the mouse models. In vitro cellular uptake of [{sup 14}C]FDG and [{sup 3}H]FLT and thymidine kinase 1 (TK{sub 1}) activity in both cell lines were measured. Expression of glucose transporter 1 (GLUT-1) and Ki-67 in xenografted tumors was evaluated by immunohistochemical staining. Results: In epithelioid mesothelioma models, biodistribution experiments showed that tumor uptake of [{sup 11}C]S-dThd was significantly higher than that of [{sup 18}F]FDG. On the other hand, in sarcomatoid models, [{sup 18}F]FDG showed significantly higher accumulation than the other two tracers. These differential uptakes of the three tracers were confirmed by PET imaging. The cellular uptake of [{sup 14}C]FDG and [{sup 3}H]FLT and TK{sub 1} activity in sarcomatoid cells were higher than those of epithelioid cells. GLUT-1 protein was strongly expressed in sarcomatoid but not in epithelioid tumor. We observed a high percentage of Ki-67-positive cells in both epithelioid and sarcomatoid tumors. Conclusions: We established nude mouse models of epithelioid and sarcomatoid subtypes of mesothelioma. PET tracers applicable for the evaluation of epithelioid and sarcomatoid mesothelioma would vary

  2. Examination of the constancy of the medium optical density of conventional chest radiographs

    International Nuclear Information System (INIS)

    Stieve, F.E.; Rupp, N.; Niederhofer, F.; Gfirtner, H.

    2002-01-01

    Purpose: To determine whether the medium optical density of conventional chest radiographs is constant. Materials and Methods: 47 PA chest radiographs were digitized to measure the optical density and its dynamic range of normal and pathologically altered lungs. Results: For constant exposure factors and a correctly positioned region of interest, the medium optical density deviates only minimal despite differences in AP chest diameter, entry dose and dynamic range, and is largely independent of the pathologic pulmonary findings. Conclusion: Digitization of the radiograph enables the determination of the physical parameters used to operate the imaging system, such as medium optical density, image contrast, image latitude and density distribution, in accordance to the guidelines of the German Medical Association. If the region of interest encompasses the clinically relevant region of the lung, the measured value of the optical density corresponds with only minor variation to the average value of the entire lung region. (orig.) [de

  3. High energy electron radiography system design and simulation study of beam angle-position correlation and aperture effect on the images

    International Nuclear Information System (INIS)

    Zhao, Quantang; Cao, S.C.; Liu, M.; Sheng, X.K.; Wang, Y.R.; Zong, Y.; Zhang, X.M.; Jing, Y.; Cheng, R.; Zhao, Y.T.; Zhang, Z.M.; Du, Y.C.; Gai, W.

    2016-01-01

    A beam line dedicated to high-energy electron radiography experimental research with linear achromat and imaging lens systems has been designed. The field of view requirement on the target and the beam angle-position correlation correction can be achieved by fine-tuning the fields of the quadrupoles used in the achromat in combination with already existing six quadrupoles before the achromat. The radiography system is designed by fully considering the space limitation of the laboratory and the beam diagnostics devices. Two kinds of imaging lens system, a quadruplet and an octuplet system are integrated into one beam line with the same object plane and image plane but with different magnification factor. The beam angle-position correlation on the target required by the imaging lens system and the aperture effect on the images are studied with particle tracking simulation. It is shown that the aperture position is also correlated to the beam angle-position on the target. With matched beam on the target, corresponding aperture position and suitable aperture radius, clear pictures can be imaged by both lens systems. The aperture is very important for the imaging. The details of the beam optical requirements, optimized parameters and the simulation results are presented.

  4. Whole-body CT in polytrauma patients: the effect of arm position on abdominal image quality when using a human phantom

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Pil-Hyun [Yonsei University, Wonju (Korea, Republic of); Wonju Christian Hospital, Wonju (Korea, Republic of); Kim, Hee-Joung; Lee, Chang-Lae; Kim, Dae-Hong [Yonsei University, Wonju (Korea, Republic of); Lee, Won-Hyung; Jeon, Sung-Su [Wonju Christian Hospital, Wonju (Korea, Republic of)

    2012-06-15

    For a considerable number of emergency computed tomography (CT) scans, patients are unable to position their arms above their head due to traumatic injuries. The arms-down position has been shown to reduce image quality with beam-hardening artifacts in the dorsal regions of the liver, spleen, and kidneys, rendering these images non-diagnostic. The purpose of this study was to evaluate the effect of arm position on the image quality in patients undergoing whole-body CT. We acquired CT scans with various acquisition parameters at voltages of 80, 120, and 140 kVp and an increasing tube current from 200 to 400 mAs in 50 mAs increments. The image noise and the contrast assessment were considered for quantitative analyses of the CT images. The image noise (IN), the contrast-to-noise ratio (CNR), the signal-to-noise ratio (SNR), and the coefficient of variation (COV) were evaluated. Quantitative analyses of the experiments were performed with CT scans representative of five different arm positions. Results of the CT scans acquired at 120 kVp and 250 mAs showed high image quality in patients with both arms raised above the head (SNR: 12.4, CNR: 10.9, and COV: 8.1) and both arms flexed at the elbows on the chest (SNR: 11.5, CNR: 10.2, and COV: 8.8) while the image quality significantly decreased with both arms in the down position (SNR: 9.1, CNR: 7.6, and COV: 11). Both arms raised, one arm raised, and both arms flexed improved the image quality compared to arms in the down position by reducing beam-hardening and streak artifacts caused by the arms being at the side of body. This study provides optimal methods for achieving higher image quality and lower noise in abdominal CT for trauma patients.

  5. Whole-body CT in polytrauma patients: The effect of arm position on abdominal image quality when using a human phantom

    Science.gov (United States)

    Jeon, Pil-Hyun; Kim, Hee-Joung; Lee, Chang-Lae; Kim, Dae-Hong; Lee, Won-Hyung; Jeon, Sung-Su

    2012-06-01

    For a considerable number of emergency computed tomography (CT) scans, patients are unable to position their arms above their head due to traumatic injuries. The arms-down position has been shown to reduce image quality with beam-hardening artifacts in the dorsal regions of the liver, spleen, and kidneys, rendering these images non-diagnostic. The purpose of this study was to evaluate the effect of arm position on the image quality in patients undergoing whole-body CT. We acquired CT scans with various acquisition parameters at voltages of 80, 120, and 140 kVp and an increasing tube current from 200 to 400 mAs in 50 mAs increments. The image noise and the contrast assessment were considered for quantitative analyses of the CT images. The image noise (IN), the contrast-to-noise ratio (CNR), the signal-to-noise ratio (SNR), and the coefficient of variation (COV) were evaluated. Quantitative analyses of the experiments were performed with CT scans representative of five different arm positions. Results of the CT scans acquired at 120 kVp and 250 mAs showed high image quality in patients with both arms raised above the head (SNR: 12.4, CNR: 10.9, and COV: 8.1) and both arms flexed at the elbows on the chest (SNR: 11.5, CNR: 10.2, and COV: 8.8) while the image quality significantly decreased with both arms in the down position (SNR: 9.1, CNR: 7.6, and COV: 11). Both arms raised, one arm raised, and both arms flexed improved the image quality compared to arms in the down position by reducing beam-hardening and streak artifacts caused by the arms being at the side of body. This study provides optimal methods for achieving higher image quality and lower noise in abdominal CT for trauma patients.

  6. Whole-body CT in polytrauma patients: the effect of arm position on abdominal image quality when using a human phantom

    International Nuclear Information System (INIS)

    Jeon, Pil-Hyun; Kim, Hee-Joung; Lee, Chang-Lae; Kim, Dae-Hong; Lee, Won-Hyung; Jeon, Sung-Su

    2012-01-01

    For a considerable number of emergency computed tomography (CT) scans, patients are unable to position their arms above their head due to traumatic injuries. The arms-down position has been shown to reduce image quality with beam-hardening artifacts in the dorsal regions of the liver, spleen, and kidneys, rendering these images non-diagnostic. The purpose of this study was to evaluate the effect of arm position on the image quality in patients undergoing whole-body CT. We acquired CT scans with various acquisition parameters at voltages of 80, 120, and 140 kVp and an increasing tube current from 200 to 400 mAs in 50 mAs increments. The image noise and the contrast assessment were considered for quantitative analyses of the CT images. The image noise (IN), the contrast-to-noise ratio (CNR), the signal-to-noise ratio (SNR), and the coefficient of variation (COV) were evaluated. Quantitative analyses of the experiments were performed with CT scans representative of five different arm positions. Results of the CT scans acquired at 120 kVp and 250 mAs showed high image quality in patients with both arms raised above the head (SNR: 12.4, CNR: 10.9, and COV: 8.1) and both arms flexed at the elbows on the chest (SNR: 11.5, CNR: 10.2, and COV: 8.8) while the image quality significantly decreased with both arms in the down position (SNR: 9.1, CNR: 7.6, and COV: 11). Both arms raised, one arm raised, and both arms flexed improved the image quality compared to arms in the down position by reducing beam-hardening and streak artifacts caused by the arms being at the side of body. This study provides optimal methods for achieving higher image quality and lower noise in abdominal CT for trauma patients.

  7. Filtering for distributed mechanical systems using position measurements: perspectives in medical imaging

    International Nuclear Information System (INIS)

    Moireau, Philippe; Chapelle, Dominique; Tallec, Patrick Le

    2009-01-01

    We propose an effective filtering methodology designed to perform estimation in a distributed mechanical system using position measurements. As in a previously introduced method, the filter is inspired by robust control feedback, but here we take full advantage of the estimation specificity to choose a feedback law that can act on displacements instead of velocities and still retain the same kind of dissipativity property which guarantees robustness. This is very valuable in many applications for which positions are more readily available than velocities, as in medical imaging. We provide an in-depth analysis of the proposed procedure, as well as detailed numerical assessments using a test problem inspired by cardiac biomechanics, as medical diagnosis assistance is an important perspective for this approach. The method is formulated first for measurements based on Lagrangian displacements, but we then derive a nonlinear extension allowing us to instead consider segmented images, which of course is even more relevant in medical applications

  8. Genetic Imaging of the Association of Oxytocin Receptor Gene (OXTR Polymorphisms with Positive Maternal Parenting

    Directory of Open Access Journals (Sweden)

    Kalina J. Michalska

    2014-02-01

    Full Text Available Background: Well-validated models of maternal behavior in small-brain mammals posit a central role of oxytocin in parenting, by reducing stress and enhancing the reward value of social interactions with offspring. In contrast, human studies are only beginning to gain insights into how oxytocin modulates maternal behavior and affiliation. Methods: To explore associations between oxytocin receptor genes and maternal parenting behavior in humans, we conducted a genetic imaging study of women selected to exhibit a wide range of observed parenting when their children were 4-6 years old. Results: In response to child stimuli during functional magnetic resonance imaging, hemodynamic responses in brain regions that mediate affect, reward, and social behavior were significantly correlated with observed positive parenting. Furthermore, single nucleotide polymorphisms (rs53576 and rs1042778 in the gene encoding the oxytocin receptor were significantly associated with both positive parenting and hemodynamic responses to child stimuli in orbitofrontal cortex, anterior cingulate cortex and hippocampus. Conclusions: These findings contribute to the emerging literature on the role of oxytocin in human social behavior and support the feasibility of tracing biological pathways from genes to neural regions to positive maternal parenting behaviors in humans using genetic imaging methods.

  9. Predicting body appreciation in young women: An integrated model of positive body image.

    Science.gov (United States)

    Andrew, Rachel; Tiggemann, Marika; Clark, Levina

    2016-09-01

    This study examined a range of predictors, based on previous theoretical models, of positive body image in young adult women. Participants were 266 women who completed an online questionnaire measuring body appreciation, activity participation, media consumption, perceived body acceptance by others, self-compassion, and autonomy. Potential mechanisms in predicting body appreciation assessed were self-objectification, social appearance comparison, and thin-ideal internalisation. Results indicated that greater perceived body acceptance by others and self-compassion, and lower appearance media consumption, self-objectification, social comparison, and thin-ideal internalisation were related to greater body appreciation. An integrated model showed that appearance media (negatively) and non-appearance media and self-compassion (positively) were associated with lower self-objectification, social comparison, and thin-ideal internalisation, which in turn related to greater body appreciation. Additionally, perceived body acceptance by others was directly associated with body appreciation. The results contribute to an understanding of potential pathways of positive body image development, thereby highlighting possible intervention targets. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. WE-E-18A-07: MAGIC: Multi-Acquisition Gain Image Correction for Mobile X-Ray Systems with Intrinsic Localization Crosshairs

    Energy Technology Data Exchange (ETDEWEB)

    Park, Y; Sharp, G [Massachusetts General Hospital, Boston, MA (United States)

    2014-06-15

    Purpose: Gain calibration for X-ray imaging systems with movable flat panel detectors (FPD) and intrinsic crosshairs is a challenge due to the geometry dependence of the heel effect and crosshair artifact. This study aims to develop a gain correction method for such systems by implementing the multi-acquisition gain image correction (MAGIC) technique. Methods: Raw flat-field images containing crosshair shadows and heel effect were acquired in 4 different FPD positions with fixed exposure parameters. The crosshair region was automatically detected and substituted with interpolated values from nearby exposed regions, generating a conventional single-image gain-map for each FPD position. Large kernel-based correction was applied to these images to correct the heel effect. A mask filter was used to invalidate the original cross-hair regions previously filled with the interpolated values. A final, seamless gain-map was created from the processed images by either the sequential filling (SF) or selective averaging (SA) techniques developed in this study. Quantitative evaluation was performed based on detective quantum efficiency improvement factor (DQEIF) for gain-corrected images using the conventional and proposed techniques. Results: Qualitatively, the MAGIC technique was found to be more effective in eliminating crosshair artifacts compared to the conventional single-image method. The mean DQEIF over the range of frequencies from 0.5 to 3.5 mm-1 were 1.09±0.06, 2.46±0.32, and 3.34±0.36 in the crosshair-artifact region and 2.35±0.31, 2.33±0.31, and 3.09±0.34 in the normal region, for the conventional, MAGIC-SF, and MAGIC-SA techniques, respectively. Conclusion: The introduced MAGIC technique is appropriate for gain calibration of an imaging system associated with a moving FPD and an intrinsic crosshair. The technique showed advantages over a conventional single image-based technique by successfully reducing residual crosshair artifacts, and higher image quality

  11. Parameter Optimization of Multi-Element Synthetic Aperture Imaging Systems

    Directory of Open Access Journals (Sweden)

    Vera Behar

    2007-03-01

    Full Text Available In conventional ultrasound imaging systems with phased arrays, the further improvement of lateral resolution requires enlarging of the number of array elements that in turn increases both, the complexity and the cost, of imaging systems. Multi-element synthetic aperture focusing (MSAF systems are a very good alternative to conventional systems with phased arrays. The benefit of the synthetic aperture is in reduction of the system complexity, cost and acquisition time. In a MSAF system considered in the paper, a group of elements transmit and receive signals simultaneously, and the transmit beam is defocused to emulate a single element response. The echo received at each element of a receive sub-aperture is recorded in the computer memory. The process of transmission/reception is repeated for all positions of a transmit sub-aperture. All the data recordings associated with each corresponding pair "transmit-receive sub-aperture" are then focused synthetically producing a low-resolution image. The final high-resolution image is formed by summing of the all low-resolution images associated with transmit/receive sub-apertures. A problem of parameter optimization of a MSAF system is considered in this paper. The quality of imaging (lateral resolution and contrast is expressed in terms of the beam characteristics - beam width and side lobe level. The comparison between the MSAF system described in the paper and an equivalent conventional phased array system shows that the MSAF system acquires images of equivalent quality much faster using only a small part of the power per image.

  12. Identification of Nasal Bone Fractures on Conventional Radiography and Facial CT: Comparison of the Diagnostic Accuracy in Different Imaging Modalities and Analysis of Interobserver Reliability

    International Nuclear Information System (INIS)

    Baek, Hye Jin; Kim, Dong Wook; Ryu, Ji Hwa; Lee, Yoo Jin

    2013-01-01

    There has been no study to compare the diagnostic accuracy of an experienced radiologist with a trainee in nasal bone fracture. To compare the diagnostic accuracy between conventional radiography and computed tomography (CT) for the identification of nasal bone fractures and to evaluate the interobserver reliability between a staff radiologist and a trainee. A total of 108 patients who underwent conventional radiography and CT after acute nasal trauma were included in this retrospective study. Two readers, a staff radiologist and a second-year resident, independently assessed the results of the imaging studies. Of the 108 patients, the presence of a nasal bone fracture was confirmed in 88 (81.5%) patients. The number of non-depressed fractures was higher than the number of depressed fractures. In nine (10.2%) patients, nasal bone fractures were only identified on conventional radiography, including three depressed and six non-depressed fractures. CT was more accurate as compared to conventional radiography for the identification of nasal bone fractures as determined by both readers (P <0.05), all diagnostic indices of an experienced radiologist were similar to or higher than those of a trainee, and κ statistics showed moderate agreement between the two diagnostic tools for both readers. There was no statistical difference in the assessment of interobserver reliability for both imaging modalities in the identification of nasal bone fractures. For the identification of nasal bone fractures, CT was significantly superior to conventional radiography. Although a staff radiologist showed better values in the identification of nasal bone fracture and differentiation between depressed and non-depressed fractures than a trainee, there was no statistically significant difference in the interpretation of conventional radiography and CT between a radiologist and a trainee

  13. Detention and positioning system for patient Treatment with conventional radiotherapy

    International Nuclear Information System (INIS)

    Hueso Bernad, Nuria; Tirado Porcar, Miriam; Del Castillo Arres, M. Jose; Broseta Tormos, M. Mercedes; Franch Martinez, Silvia; Suarez Dieguez, Raquel; Roures Ramos, M.Teresa

    2009-01-01

    The first step in what we call in radiotherapy S imulation and Planning o f radiation, is the correct choice of patient position and methods to use for this position is maintained along both the simulation and planning as the radiation treatment. The choice of position is directly linked to the choice of immobilizer to be used. (Author)

  14. ''Augmented reality'' in conventional simulation by projection of 3-D structures into 2-D images. A comparison with virtual methods

    International Nuclear Information System (INIS)

    Deutschmann, H.; Nairz, O.; Zehentmayr, F.; Fastner, G.; Sedlmayer, F.; Steininger, P.; Kopp, P.; Merz, F.; Wurstbauer, K.; Kranzinger, M.; Kametriser, G.; Kopp, M.

    2008-01-01

    Background and purpose: in this study, a new method is introduced, which allows the overlay of three-dimensional structures, that have been delineated on transverse slices, onto the fluoroscopy from conventional simulators in real time. Patients and methods: setup deviations between volumetric imaging and simulation were visualized, measured and corrected for 701 patient isocenters. Results: comparing the accuracy to mere virtual simulation lacking additional X-ray imaging, a clear benefit of the new method could be shown. On average, virtual prostate simulations had to be corrected by 0.48 cm (standard deviation [SD] 0.38), and those of the breast by 0.67 cm (SD 0.66). Conclusion: the presented method provides an easy way to determine entity-specific safety margins related to patient setup errors upon registration of bony anatomy (prostate 0.9 cm for 90% of cases, breast 1.3 cm). The important role of planar X-ray imaging was clearly demonstrated. The innovation can also be applied to adaptive image-guided radiotherapy (IGRT) protocols. (orig.)

  15. How does arm positioning of polytraumatized patients in the initial computed tomography (CT) affect image quality and diagnostic accuracy?

    International Nuclear Information System (INIS)

    Kahn, Johannes; Grupp, Ulrich; Maurer, Martin

    2014-01-01

    Purpose: To evaluate the influence of different arm positions on abdominal image quality during initial whole-body CT (WBCT) in polytraumatized patients and to assess the risk of missing potentially life-threatening injuries due to arm artifacts. Materials and methods: Between July 2011 and February 2013, WBCT scans of 203 patients with arms in the abdominal area during initial WBCT were analyzed. Six different arms-down positions were defined: patients with both (group A)/one arm(s) (group B) down alongside the torso, patients with both (group C)/one arm(s) (group D) crossed in front of the upper abdomen, patients with both (group E)/one arm(s) (group F) crossed in front of the pelvic area. A group of 203 patients with elevated arms beside the head served as a control group. Two observers jointly evaluated image quality of different organ regions using a 4-point scale system. Follow-up examinations (CT scans and/or ultrasound) were analyzed to identify findings missed during initial WBCT due to reduced image quality. Results: Image quality for most of the organ regions analyzed was found to be significantly different among all groups (p < 0.05). Image quality was most severely degraded in group A, followed by groups E and C. Positioning with one arm up resulted in significantly better image quality than both arms down (p < 0.05). Overall, arms-up positioning showed significantly better image quality than arms-down positions (p < 0.05). In one case, liver hemorrhage missed in the initial WBCT because of arm artifacts, was revealed by follow-up CT. Conclusion: In WBCT arms-down positioning significantly degrades abdominal image quality and artifacts might even conceal potentially life-threatening injuries. If the patient's status does not allow elevation of both arms, image quality can benefit from raising at least one arm. Otherwise, arms should be placed in front of the upper abdomen instead of alongside the torso

  16. Image quality of high-resolution CT with 16-channel multidetector-row CT. Comparison between helical scan and conventional step-shoot scan

    International Nuclear Information System (INIS)

    Sumikawa, Hiromitsu; Johkoh, Takeshi; Koyama, Mitsuhiro

    2005-01-01

    The aim of this study was to evaluate the image quality of high-resolution CT (HRCT) reconstructed from volumetric data with 16-channel multidetector-row CT (MDCT). Eleven autopsy lungs that were diagnosed histopathologically were scanned by 16-channel MDCT with the step-and-shoot scan mode and three helical scan modes. Each helical mode had each size of focal spot, pitch, and time of gantry rotation. HRCT images were reconstructed from the volumetric data with each helical mode and axial sequence data. Two observers evaluated the image quality and noted the most appropriate diagnosis for each imaging. Visualization of abnormal structures with one helical mode was equal to those with axial mode, whereas those with the other two helical modes were inferior to those with axial mode (Wilcoxon signed rank test; p<0.0001). There was no significant difference in diagnostic efficacy between modes. The image quality of HRCT with appropriate helical mode is equal to that with axial mode and diagnostic efficacy is equal among all modes. These results may indicate that sufficient HRCT images can be obtained by only one helical scan without the addition of conventional axial scans. (author)

  17. Impact of low-energy CT imaging on selection of positive oral contrast media concentration.

    Science.gov (United States)

    Patino, Manuel; Murcia, Diana J; Iamurri, Andrea Prochowski; Kambadakone, Avinash R; Hahn, Peter F; Sahani, Dushyant V

    2017-05-01

    To determine to what extent low-energy CT imaging affects attenuation of gastrointestinal tract (GIT) opacified with positive oral contrast media (OCM). Second, to establish optimal OCM concentrations for low-energy diagnostic CT exams. One hundred patients (38 men and 62 women; age 62 ± 11 years; BMI 26 ± 5) with positive OCM-enhanced 120-kVp single-energy CT (SECT), and follow-up 100-kVp acquisitions (group A; n = 50), or 40-70-keV reconstructions from rapid kV switching-single-source dual-energy CT (ssDECT) (group B; n = 50) were included. Luminal attenuation from different GIT segments was compared between exams. Standard dose of three OCM and diluted solutions (75%, 50%, and 25% concentrations) were introduced serially in a gastrointestinal phantom and scanned using SECT (120, 100, and 80 kVp) and DECT (80/140 kVp) acquisitions on a ssDECT scanner. Luminal attenuation was obtained on SECT and DECT images (40-70 keV), and compared to 120-kVp scans with standard OCM concentrations. Luminal attenuation was higher on 100-kVp (328 HU) and on 40-60-keV images (410-924 HU) in comparison to 120-kVp scans (298 HU) in groups A and B (p < 0.05). Phantom: There was an inverse correlation between luminal attenuation and X-ray energy, increasing up to 527 HU on low-kVp and 999 HU on low-keV images (p < 0.05). 25% and 50% diluted OCM solutions provided similar or higher attenuation than 120 kVp, at low kVp and keV, respectively. Low-energy CT imaging increases the attenuation of GIT opacified with positive OCM, permitting reduction of 25%-75% OCM concentration.

  18. A Novel, Aqueous Surface Treatment To Thermally Stabilize High Resolution Positive Photoresist Images*

    Science.gov (United States)

    Grunwald, John J.; Spencer, Allen C.

    1986-07-01

    The paper describes a new approach to thermally stabilize the already imaged profile of high resolution positive photoresists such as ULTRAMAC" PR-914. ***XD-4000, an aqueous emulsion of a blend of fluorine-bearing compounds is spun on top of the developed, positive photoresist-imaged wafer, and baked. This allows the photoresist to withstand temperatures up to at least 175 deg. C. while essentially maintaining vertical edge profiles. Also, adverse effects of "outgassing" in harsh environments, ie., plasma and ion implant are greatly minimized by allowing the high resolution imaged photoresist to be post-baked at "elevated" temperatures. Another type of product that accomplishes the same effect is ***XD-4005, an aqueous emulsion of a high temperature-resistant polymer. While the exact mechanism is yet to be identified, it is postulated that absorption of the "polymeric" species into the "skin" of the imaged resist forms a temperature resistant "envelope", thereby allowing high resolution photoresists to also serve in a "high temperature" mode, without reticulation, or other adverse effects due to thermal degradation. SEM's are presented showing imaged ULTRAMAC" PR-914 and ULTRAMAC" **EPA-914 geometries coated with XD-4000 or XD-4005 and followed by plasma etched oxide,polysilicon and aluminum. Selectivity ratios are compared with and without the novel treatment and are shown to be significantly better with the treatment. The surface-treated photoresist for thermal resistance remains easily strippable in solvent-based or plasma media, unlike photoresists that have undergone "PRIST" or other gaseous thermal stabilization methods.

  19. Emergency CT head and neck imaging: effects of swimmer's position on dose and image quality

    Energy Technology Data Exchange (ETDEWEB)

    Mueck, Fabian G.; Roesch, Sebastian; Geyer, Lucas; Scherr, Michael; Seidenbusch, Michael; Stahl, Robert; Deak, Zsuzsanna; Wirth, Stefan [LMU Klinikum Universitaet Muenchen (Germany). Inst. fuer Klinische Radiologie

    2014-05-15

    To compare the effects of different arm positions on dose exposure and image quality (IQ) in cervical spine CT after trauma in different patient groups. Patients in standard (STD = 126) and in swimmer's position (SWIM = 254) were included. Body mass index (BMI subgroup 1 = underweight to subgroup 4 = obese), anterior-posterior diameter (AP), left-right diameter (LR), area of an ellipse (AoE) and angle between the humeral heads (optimal STD < 3 , optimal SWIM > 10 ) were used as grouping criteria. Computed tomography dose index (CTDI) was documented. Two radiologists rated the IQ at three levels (CV1/2, CV4/5, CV7/T1) using a semi-quantitative scale (0 = not diagnostic, 1 = diagnostic with limitations, 2 = diagnostic without limitations). The Mann-Whitney U test correlations of grouping criteria with dose effects and intra-class correlation (ICC) were calculated. ICC was 0.87. BMI grouping showed the strongest correlation with dose effects: CTDI of optimal STD versus optimal SWIM positioning was 3.17 mGy versus 2.46 mGy (subgroup 1), 5.47 mGy versus 3.97 mGy (subgroup 2), 7.35 mGy versus 5.96 mGy (subgroup 3) and 8.71 mGy versus 8.18 mGy (subgroup 4). Mean IQ at CV7/T1 was 1.65 versus 1.23 (subgroup 1), 1.27 versus 1.46 (subgroup 2), 1.06 versus 1.46 (subgroup 3), 0.79 versus 1.5 (subgroup 4). Patients with a BMI > 20 kg/m{sup 2} benefited from both potential dose reduction and improved image quality at the critical cervicothoracic junction when swimmer's position was used. (orig.)

  20. New possibilities in the prevention of eating disorders: The introduction of positive body image measures.

    Science.gov (United States)

    Piran, Niva

    2015-06-01

    Delineating positive psychological processes in inhabiting the body, as well as quantitative measures to assess them, can facilitate progress in the field of prevention of eating disorders by expanding outcome evaluation of prevention interventions, identifying novel mediators of change, and increasing highly needed research into protective factors. Moreover, enhancing positive ways of inhabiting the body may contribute toward the maintenance of gains of prevention interventions. Integrated social etiological models to eating disorders that focus on gender and other social variables, such as the Developmental Theory of Embodiment (Piran & Teall, 2012a), can contribute to positive body image intervention development and research within the prevention field. Using the Developmental Theory of Embodiment as a lens, this article explores whether existing prevention programs (i.e., Cognitive Dissonance and Media Smart) may already work to promote positive body image, and whether prevention programs need to be expanded toward this goal. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Incidental lung cancers and positive computed tomography images in people living with HIV

    DEFF Research Database (Denmark)

    Ronit, Andreas; Kristensen, Thomas; Klitbo, Ditte M.

    2017-01-01

    in 901 patients, including 113 at high risk for lung cancer. A positive image was found in 28 (3.1% of the entire cohort and 9.7% of the high-risk group). Nine patients (all in the high-risk group) had invasive procedures undertaken with no serious adverse events. Lung cancer (stages IA, IIA, and IIIA......Objective: Lung cancer screening with low-dose computed tomography (LDCT) of high-risk groups in the general population is recommended by several authorities. This may not be feasible in people living with HIV (PLWHIV) due to higher prevalence of nodules. We therefore assessed the prevalence...... of positive computed tomography (CT) images and lung cancers in PLWHIV. Design: The Copenhagen comorbidity in HIV infection (COCOMO) study is an observational, longitudinal cohort study. Single-round LDCT was performed with subsequent clinical follow-up (NCT02382822). Method: Outcomes included histology...

  2. Linearized inversion frameworks toward high-resolution seismic imaging

    KAUST Repository

    Aldawood, Ali

    2016-09-01

    Seismic exploration utilizes controlled sources, which emit seismic waves that propagate through the earth subsurface and get reflected off subsurface interfaces and scatterers. The reflected and scattered waves are recorded by recording stations installed along the earth surface or down boreholes. Seismic imaging is a powerful tool to map these reflected and scattered energy back to their subsurface scattering or reflection points. Seismic imaging is conventionally based on the single-scattering assumption, where only energy that bounces once off a subsurface scatterer and recorded by a receiver is projected back to its subsurface position. The internally multiply scattered seismic energy is considered as unwanted noise and is usually suppressed or removed from the recorded data. Conventional seismic imaging techniques yield subsurface images that suffer from low spatial resolution, migration artifacts, and acquisition fingerprint due to the limited acquisition aperture, number of sources and receivers, and bandwidth of the source wavelet. Hydrocarbon traps are becoming more challenging and considerable reserves are trapped in stratigraphic and pinch-out traps, which require highly resolved seismic images to delineate them. This thesis focuses on developing and implementing new advanced cost-effective seismic imaging techniques aiming at enhancing the resolution of the migrated images by exploiting the sparseness of the subsurface reflectivity distribution and utilizing the multiples that are usually neglected when imaging seismic data. I first formulate the seismic imaging problem as a Basis pursuit denoise problem, which I solve using an L1-minimization algorithm to obtain the sparsest migrated image corresponding to the recorded data. Imaging multiples may illuminate subsurface zones, which are not easily illuminated by conventional seismic imaging using primary reflections only. I then develop an L2-norm (i.e. least-squares) inversion technique to image

  3. Robot-assisted radical prostatectomy: Multiparametric MR imaging-directed intraoperative frozen-section analysis to reduce the rate of positive surgical margins.

    Science.gov (United States)

    Petralia, Giuseppe; Musi, Gennaro; Padhani, Anwar R; Summers, Paul; Renne, Giuseppe; Alessi, Sarah; Raimondi, Sara; Matei, Deliu V; Renne, Salvatore L; Jereczek-Fossa, Barbara A; De Cobelli, Ottavio; Bellomi, Massimo

    2015-02-01

    To investigate whether use of multiparametric magnetic resonance (MR) imaging-directed intraoperative frozen-section (IFS) analysis during nerve-sparing robot-assisted radical prostatectomy reduces the rate of positive surgical margins. This retrospective analysis of prospectively acquired data was approved by an institutional ethics committee, and the requirement for informed consent was waived. Data were reviewed for 134 patients who underwent preoperative multiparametric MR imaging (T2 weighted, diffusion weighted, and dynamic contrast-material enhanced) and nerve-sparing robot-assisted radical prostatectomy, during which IFS analysis was used, and secondary resections were performed when IFS results were positive for cancer. Control patients (n = 134) matched for age, prostate-specific antigen level, and stage were selected from a pool of 322 patients who underwent nerve-sparing robot-assisted radical prostatectomy without multiparametric MR imaging and IFS analysis. Rates of positive surgical margins were compared by means of the McNemar test, and a multivariate conditional logistic regression model was used to estimate the odds ratio of positive surgical margins for patients who underwent MR imaging and IFS analysis compared with control subjects. Eighteen patients who underwent MR imaging and IFS analysis underwent secondary resections, and 13 of these patients were found to have negative surgical margins at final pathologic examination. Positive surgical margins were found less frequently in the patients who underwent MR imaging and IFS analysis than in control patients (7.5% vs 18.7%, P = .01). When the differences in risk factors are taken into account, patients who underwent MR imaging and IFS had one-seventh the risk of having positive surgical margins relative to control patients (adjusted odds ratio: 0.15; 95% confidence interval: 0.04, 0.61). The significantly lower rate of positive surgical margins compared with that in control patients provides

  4. A study on evaluating validity of SNR calculation using a conventional two region method in MR images applied a multichannel coil and parallel imaging technique

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Kwan Woo; Son, Soon Yong [Dept. of Radiology, Asan Medical Center, Seoul (Korea, Republic of); Min, Jung Whan [Dept. of Radiological Technology, Shingu University, Sungnam (Korea, Republic of); Kwon, Kyung Tae [Dept. of Radiological Technology, Dongnam Health University, Suwon (Korea, Republic of); Yoo, Beong Gyu; Lee, Jong Seok [Dept. of Radiotechnology, Wonkwang Health Science University, Iksan (Korea, Republic of)

    2015-12-15

    The purpose of this study was to investigate the problems of a signal to noise ratio measurement using a two region measurement method that is conventionally used when using a multi-channel coil and a parallel imaging technique. As a research method, after calculating the standard SNR using a single channel head coil of which coil satisfies three preconditions when using a two region measurement method, we made comparisons and evaluations after calculating an SNR by using a two region measurement method of which method is problematic because it is used without considering the methods recommended by reputable organizations and the preconditions at the time of using a multi-channel coil and a parallel imaging technique. We found that a two region measurement method using a multi-channel coil and a parallel imaging technique shows the highest relative standard deviation, and thus shows a low degree of precision. In addition, we found out that the difference of SNR according to ROI location was very high, and thus a spatial noise distribution was not uniform. Also, 95% confidence interval through Blend-Altman plot is the widest, and thus the conformity degree with a two region measurement method using the standard single channel head coil is low. By directly comparing an AAPM method, which serves as a standard of a performance evaluation test of a magnetic resonance imaging device under the same image acquisition conditions, an NEMA method which can accurately determine the noise level in a signal region and the methods recommended by manufacturers of a magnetic resonance imaging device, there is a significance in that we quantitatively verified the inaccurate problems of a signal to noise ratio using a two region measurement method when using a multi-channel coil and a parallel imaging technique of which method does not satisfy the preconditions that researchers could overlook.

  5. Low-dose phase contrast tomography with conventional x-ray sources

    Energy Technology Data Exchange (ETDEWEB)

    Hagen, C. K., E-mail: charlotte.hagen.10@ucl.ac.uk; Endrizzi, M.; Diemoz, P. C.; Olivo, A. [Department of Medical Physics and Bioengineering, University College London, Malet Place, Gower Street, London WC1E 6BT (United Kingdom); Munro, P. R. T. [Optical + Biomedical Engineering Laboratory, School of Electrical, Electronic and Computer Engineering, The University of Western Australia, 35 Stirling Highway, Crawley, Western Australia 6009, Australia and Centre for Microscopy, Characterisation, and Analysis, The University of Western Australia, 35 Stirling Highway, Crawley, Western Australia 6009 (Australia)

    2014-07-15

    Purpose: The edge illumination (EI) x-ray phase contrast imaging (XPCi) method has been recently further developed to perform tomographic and, thus, volumetric imaging. In this paper, the first tomographic EI XPCi images acquired with a conventional x-ray source at dose levels below that used for preclinical small animal imaging are presented. Methods: Two test objects, a biological sample and a custom-built phantom, were imaged with a laboratory-based EI XPCi setup in tomography mode. Tomographic maps that show the phase shift and attenuating properties of the object were reconstructed, and analyzed in terms of signal-to-noise ratio and quantitative accuracy. Dose measurements using thermoluminescence devices were performed. Results: The obtained images demonstrate that phase based imaging methods can provide superior results compared to attenuation based modalities for weakly attenuating samples also in 3D. Moreover, and, most importantly, they demonstrate the feasibility of low-dose imaging. In addition, the experimental results can be considered quantitative within the constraints imposed by polychromaticity. Conclusions: The results, together with the method's dose efficiency and compatibility with conventional x-ray sources, indicate that tomographic EI XPCi can become an important tool for the routine imaging of biomedical samples.

  6. 3.0 T conventional hip MR and hip MR arthrography for the acetabular labral tears confirmed by arthroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Chun-Yan [Department of Radiology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing 100191 (China); Wang, Jian-Quan [Department of Sports Medicine, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing 100191,PR China (China); Zheng, Zhuo-Zhao, E-mail: zzhuozhao@aliyun.com [Department of Radiology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing 100191 (China); Ren, A.-Hong [Department of Radiology, Beijing Daxing Hospital, 26 West Huangcun Road, Daxing District, Beijing 102600 (China)

    2014-10-15

    Highlights: • MR is the preferred imaging modality for diagnosing acetabular labral tears. • The diagnostic performance of MR arthrography are superior than conventional hip MR. • The hip MR arthrography is recommended for diagnosing acetabular labral lesions. - Abstract: Objective: To evaluate the value of hip MR for diagnosing acetabular labrum tears, and to further compare the diagnostic performances of conventional MR with MR arthrography in acetabular labrum tears. Methods: 90 patients undergoing both hip MR examination and subsequent hip arthroscopy were retrospectively evaluated. Of these patients, 34 accepted both conventional MR and MR arthrography; while the other 56 only underwent conventional MR examination. All hip MR images were independently reviewed by two radiologists, and further compared with the results of hip arthroscopy. Results: 59 of 90 patients were confirmed with acetabular labral tears by hip arthroscopy and 31 without tears. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of conventional MR for evaluating the acetabular labral tears were 61.0%, 77.4%, 83.7% and 51.1% (radiologist A), and 66.1%, 74.2%, 82.9% and 53.4% (radiologist B), respectively, with good consistency between the two observers (K = 0.645). The sensitivity, specificity, PPV and NPV of MR arthrography for assessing the acetabular labral tears were 90.5%, 84.6%, 90.5% and 84.6% (radiologist A), and 95.2%, 84.6%, 90.9% and 91.7% (radiologist B), respectively, with excellent good consistency between the two observers (K = 0.810). The sensitivity and NPV of MR arthrography for diagnosing the acetabular labral tears were significantly higher than those of conventional MR (both P < 0.05). Conclusion: Hip MR arthrography is a reliable evaluation modality for diagnosing the acetabular labral tears, and its diagnostic performance is superior to that of conventional MR at 3.0 T.

  7. Position measuring device

    International Nuclear Information System (INIS)

    Maeda, Kazuyuki; Takahashi, Shuichi; Maruyama, Mayumi

    1998-01-01

    The present invention provides a device capable of measuring accurate position and distance easily even at places where operator can not easily access, such as cell facilities for vitrifying radioactive wastes. Referring to a case of the vitrifying cell, an objective equipment settled in the cell is photographed by a photographing device. The image is stored in a position measuring device by way of an image input device. After several years, when the objective equipment is exchanged, a new objective equipment is photographed by a photographing device. The image is also stored in the position measuring device. The position measuring device compares the data of both of the images on the basis of pixel unit. Based on the image of the equipment before the exchange as a reference, extent of the displacement of the installation position of the equipment on the image after the exchange caused by installation error and manufacturing error is determined to decide the position of the equipment after exchange relative to the equipment before exchange. (I.S.)

  8. An in vitro comparison of photogrammetric and conventional complete-arch implant impression techniques.

    Science.gov (United States)

    Bergin, Junping Ma; Rubenstein, Jeffrey E; Mancl, Lloyd; Brudvik, James S; Raigrodski, Ariel J

    2013-10-01

    Conventional impression techniques for recording the location and orientation of implant-supported, complete-arch prostheses are time consuming and prone to error. The direct optical recording of the location and orientation of implants, without the need for intermediate transfer steps, could reduce or eliminate those disadvantages. The objective of this study was to assess the feasibility of using a photogrammetric technique to record the location and orientation of multiple implants and to compare the results with those of a conventional complete-arch impression technique. A stone cast of an edentulous mandibular arch containing 5 implant analogs was fabricated to create a master model. The 3-dimensional (3D) spatial orientations of implant analogs on the master model were measured with a coordinate measuring machine (CMM) (control). Five definitive casts were made from the master model with a splinted impression technique. The positions of the implant analogs on the 5 casts were measured with a NobelProcera scanner (conventional method). Prototype optical targets were attached to the master model implant analogs, and 5 sets of images were recorded with a digital camera and a standardized image capture protocol. Dimensional data were imported into commercially available photogrammetry software (photogrammetric method). The precision and accuracy of the 2 methods were compared with a 2-sample t test (α=.05) and a 95% confidence interval. The location precision (standard error of measurement) for CMM was 3.9 µm (95% CI 2.7 to 7.1), for photogrammetry, 5.6 µm (95% CI 3.4 to 16.1), and for the conventional method, 17.2 µm (95% CI 10.3 to 49.4). The average measurement error was 26.2 µm (95% CI 15.9 to 36.6) for the conventional method and 28.8 µm (95% CI 24.8 to 32.9) for the photogrammetric method. The overall measurement accuracy was not significantly different when comparing the conventional to the photogrammetric method (mean difference = -2.6 µm, 95% CI

  9. Multiparameter double hole contrast detail phantom: Ability to detect image displacement due to off position anode stem

    International Nuclear Information System (INIS)

    Pauzi, Nur Farahana; Majid, Zafri Azran Abdul; Sapuan, Abdul Halim; Junet, Laila Kalidah; Azemin, Mohd Zulfaezal Che

    2015-01-01

    Contrast Detail phantom is a quality control tool to analyze the performance of imaging devices. Currently, its function is solely to evaluate the contrast detail characteristic of imaging system. It consists of drilled hole which gives effect to the penetration of x-ray beam divergence to pass through the base of each hole. This effect will lead to false appearance of image from its original location but it does not being visualized in the radiograph. In this study, a new design of Contrast Detail phantom’s hole which consists of double hole construction has been developed. It can detect the image displacement which is due to off position of anode stem from its original location. The double hole differs from previous milled hole, whereby it consists of combination of different hole diameters. Small hole diameter (3 mm) is positioned on top of larger hole diameter (10 mm). The thickness of double hole acrylic blocks is 13 mm. Result revealed that Multiparameter Double Hole Contrast Detail phantom can visualize the shifted flaw image quality produced by x-ray machine due to improper position of the anode stem which is attached to rotor and stator. The effective focal spot of x-ray beam also has been shifted from the center of collimator as a result of off-position anode stem. As a conclusion, the new design of double hole Contrast Detail phantom able to measure those parameters in a well manner

  10. Multiparameter double hole contrast detail phantom: Ability to detect image displacement due to off position anode stem

    Energy Technology Data Exchange (ETDEWEB)

    Pauzi, Nur Farahana; Majid, Zafri Azran Abdul; Sapuan, Abdul Halim; Junet, Laila Kalidah [Department of Diagnostic Imaging and Radiotherapy, Kulliyyah of Allied Health Sciences, International Islamic University Malaysia, Jalan Istana, 25200, Kuantan, Pahang (Malaysia); Azemin, Mohd Zulfaezal Che [Department of Optometry and Visual Science, Kulliyyah of Allied Health Sciences, International Islamic University Malaysia, Jalan Istana, 25200, Kuantan, Pahang (Malaysia)

    2015-04-24

    Contrast Detail phantom is a quality control tool to analyze the performance of imaging devices. Currently, its function is solely to evaluate the contrast detail characteristic of imaging system. It consists of drilled hole which gives effect to the penetration of x-ray beam divergence to pass through the base of each hole. This effect will lead to false appearance of image from its original location but it does not being visualized in the radiograph. In this study, a new design of Contrast Detail phantom’s hole which consists of double hole construction has been developed. It can detect the image displacement which is due to off position of anode stem from its original location. The double hole differs from previous milled hole, whereby it consists of combination of different hole diameters. Small hole diameter (3 mm) is positioned on top of larger hole diameter (10 mm). The thickness of double hole acrylic blocks is 13 mm. Result revealed that Multiparameter Double Hole Contrast Detail phantom can visualize the shifted flaw image quality produced by x-ray machine due to improper position of the anode stem which is attached to rotor and stator. The effective focal spot of x-ray beam also has been shifted from the center of collimator as a result of off-position anode stem. As a conclusion, the new design of double hole Contrast Detail phantom able to measure those parameters in a well manner.

  11. Assessment of female ballet dancers' ankles in the en pointe position using high field strength magnetic resonance imaging.

    Science.gov (United States)

    Russell, Jeffrey A; Yoshioka, Hiroshi

    2016-08-01

    The en pointe position of the ankle in ballet is extreme. Previously, magnetic resonance imaging (MRI) of ballet dancers' ankles en pointe was confined to a low field, open MR device. To develop a reproducible ankle MRI protocol for ballet dancers en pointe and to assess the positions of the key structures in the dancers ankles. Six female ballet dancers participated; each was randomly assigned to stand en pointe while one of her feet and ankles was splinted with wooden rods affixed with straps or to begin with the ankle in neutral position. She lay in an MR scanner with the ankle inside a knee coil for en pointe imaging and inside an ankle/foot coil for neutral position imaging. Proton density weighted images with and without fat suppression and 3D water excitation gradient recalled echo images were obtained en pointe and in neutral position in sagittal, axial, and coronal planes. We compared the bones, cartilage, and soft tissues within and between positions. No difficulties using the protocol were encountered. En pointe the posterior articular surface of the tibial plafond was incongruent with the talar dome and rested on the posterior talus. The posterior edge of the plafond impinged Kager's fat pad. All participants exhibited one or more small ganglion cysts about the ankle and proximal foot, as well as fluid accumulation in the flexor and fibularis tendon sheaths. Our MRI protocol allows assessment of female ballet dancers' ankles in the extreme plantar flexion position in which the dancers perform. We consistently noted incongruence of the talocrural joint and convergence of the tibia, talus, and calcaneus posteriorly. This protocol may be useful for clinicians who evaluate dancers. © The Foundation Acta Radiologica 2015.

  12. Comparison of image uniformity with photon counting and conventional scintillation single-photon emission computed tomography system: A Monte Carlo simulation study

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ho Chul; Lee, Young Jin [Dept. of Radiological Science, Eulji University, Seongnam (Korea, Republic of); Kim, Hee Joung; Kim, Kyuseok; Lee, Min Hee [Yonsei University, Wonju (Korea, Republic of)

    2017-06-15

    To avoid imaging artifacts and interpretation mistakes, an improvement of the uniformity in gamma camera systems is a very important point. We can expect excellent uniformity using cadmium zinc telluride (CZT) photon counting detector (PCD) because of the direct conversion of the gamma rays energy into electrons. In addition, the uniformity performance such as integral uniformity (IU), differential uniformity (DU), scatter fraction (SF), and contrast-to-noise ratio (CNR) varies according to the energy window setting. In this study, we compared a PCD and conventional scintillation detector with respect to the energy windows (5%, 10%, 15%, and 20%) using a {sup 99m}Tc gamma source with a Geant4 Application for Tomography Emission simulation tool. The gamma camera systems used in this work are a CZT PCD and NaI(Tl) conventional scintillation detector with a 1-mm thickness. According to the results, although the IU and DU results were improved with the energy window, the SF and CNR results deteriorated with the energy window. In particular, the uniformity for the PCD was higher than that of the conventional scintillation detector in all cases. In conclusion, our results demonstrated that the uniformity of the CZT PCD was higher than that of the conventional scintillation detector.

  13. Conventions and workflows for using Situs

    International Nuclear Information System (INIS)

    Wriggers, Willy

    2012-01-01

    Recent developments of the Situs software suite for multi-scale modeling are reviewed. Typical workflows and conventions encountered during processing of biophysical data from electron microscopy, tomography or small-angle X-ray scattering are described. Situs is a modular program package for the multi-scale modeling of atomic resolution structures and low-resolution biophysical data from electron microscopy, tomography or small-angle X-ray scattering. This article provides an overview of recent developments in the Situs package, with an emphasis on workflows and conventions that are important for practical applications. The modular design of the programs facilitates scripting in the bash shell that allows specific programs to be combined in creative ways that go beyond the original intent of the developers. Several scripting-enabled functionalities, such as flexible transformations of data type, the use of symmetry constraints or the creation of two-dimensional projection images, are described. The processing of low-resolution biophysical maps in such workflows follows not only first principles but often relies on implicit conventions. Situs conventions related to map formats, resolution, correlation functions and feature detection are reviewed and summarized. The compatibility of the Situs workflow with CCP4 conventions and programs is discussed

  14. Differential impact of multi-focus fan beam collimation with L-mode and conventional systems on the accuracy of myocardial perfusion imaging: Quantitative evaluation using phantoms

    International Nuclear Information System (INIS)

    Onishi, Hideo; Matsutomo, Norikazu; Kangai, Yoshiharu; Saho, Tatsunori; Amijima, Hizuru

    2013-01-01

    A novel IQ-SPECT™ method has become widely used in clinical studies. The present study compares the quality of myocardial perfusion images (MPI) acquired using the IQ-SPECT™ (IQ-mode), conventional (180° apart: C-mode) and L-mode (90° apart: L-mode) systems. We assessed spatial resolution, image reproducibility and quantifiability using various physical phantoms. SPECT images were acquired using a dual-headed gamma camera with C-mode, L-mode, and IQ-mode acquisition systems from line source, pai and cardiac phantoms containing solutions of 99m Tc. The line source phantom was placed in the center of the orbit and at ± 4.0, ± 8.0, ± 12.0, ± 16.0 and ± 20.0 cm off center. We examined quantifiability using the pai phantom comprising six chambers containing 0.0, 0.016, 0.03, 0.045, 0.062, and 0.074 MBq/mL of 99m-Tc and cross-calibrating the SPECT counts. Image resolution and reproducibility were quantified as myocardial wall thickness (MWT) and %uptake using polar maps. The full width at half maximum (FWHM) of the IQ-mode in the center was increased by 11% as compared with C-mode, and FWHM in the periphery was increased 41% compared with FWHM at the center. Calibrated SPECT counts were essentially the same when quantified using IQ-and C-modes. IQ-SPECT images of MWT were significantly improved (P<0.001) over L-mode, and C-mode SPECT imaging with IQ-mode became increasingly inhomogeneous, both visually and quantitatively (C-mode vs. L-mode, ns; C-mode vs. IQ-mode, P<0.05). Myocardial perfusion images acquired by IQ-SPECT were comparable to those acquired by conventional and L-mode SPECT, but with significantly improved resolution and quality. Our results suggest that IQ-SPECT is the optimal technology for myocardial perfusion SPECT imaging

  15. Diffraction contrast imaging using virtual apertures

    International Nuclear Information System (INIS)

    Gammer, Christoph; Burak Ozdol, V.; Liebscher, Christian H.; Minor, Andrew M.

    2015-01-01

    Two methods on how to obtain the full diffraction information from a sample region and the associated reconstruction of images or diffraction patterns using virtual apertures are demonstrated. In a STEM-based approach, diffraction patterns are recorded for each beam position using a small probe convergence angle. Similarly, a tilt series of TEM dark-field images is acquired. The resulting datasets allow the reconstruction of either electron diffraction patterns, or bright-, dark- or annular dark-field images using virtual apertures. The experimental procedures of both methods are presented in the paper and are applied to a precipitation strengthened and creep deformed ferritic alloy with a complex microstructure. The reconstructed virtual images are compared with conventional TEM images. The major advantage is that arbitrarily shaped virtual apertures generated with image processing software can be designed without facing any physical limitations. In addition, any virtual detector that is specifically designed according to the underlying crystal structure can be created to optimize image contrast. - Highlights: • A dataset containing all structural information of a given position is recorded. • The dataset allows reconstruction of virtual diffraction patterns or images. • Specific virtual apertures are designed to image precipitates in a complex alloy. • Virtual diffraction patterns from arbitrarily small regions can be established. • Using STEM diffraction to record the dataset is more efficient than TEM dark-field

  16. Cecal volvulus: a rare cause of bowel obstruction in a pediatric patient diagnosed pre-operatively by conventional imaging studies

    International Nuclear Information System (INIS)

    Vo, Nghia J.; O'Hara, Sara M.; Alonso, Maria H.

    2005-01-01

    Cecal volvulus is an acute surgical condition that is extremely rare in children, with a mortality rate of up to 40%. The clinical symptoms are often non-specific, and pediatric patients frequently have neurological deficits with associated communication difficulties, making the clinical diagnosis extremely challenging. Conventional radiographic imaging studies play a key role in the prospective diagnosis in children. We report a rare case of cecal volvulus in a 12-year-old boy who was diagnosed pre-operatively by abdominal radiographs and a contrast enema. (orig.)

  17. Cecal volvulus: a rare cause of bowel obstruction in a pediatric patient diagnosed pre-operatively by conventional imaging studies

    Energy Technology Data Exchange (ETDEWEB)

    Vo, Nghia J.; O' Hara, Sara M. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati (United States); Alonso, Maria H. [Cincinnati Children' s Hospital Medical Center, Division of Pediatric and Thoracic Surgery, Cincinnati, Ohio (United States)

    2005-11-01

    Cecal volvulus is an acute surgical condition that is extremely rare in children, with a mortality rate of up to 40%. The clinical symptoms are often non-specific, and pediatric patients frequently have neurological deficits with associated communication difficulties, making the clinical diagnosis extremely challenging. Conventional radiographic imaging studies play a key role in the prospective diagnosis in children. We report a rare case of cecal volvulus in a 12-year-old boy who was diagnosed pre-operatively by abdominal radiographs and a contrast enema. (orig.)

  18. Minimally invasive, imaging guided virtual autopsy compared to conventional autopsy in foetal, newborn and infant cases: study protocol for the paediatric virtual autopsy trial

    Science.gov (United States)

    2014-01-01

    Background In light of declining autopsy rates around the world, post-mortem MR imaging is a promising alternative to conventional autopsy in the investigation of infant death. A major drawback of this non-invasive autopsy approach is the fact that histopathological and microbiological examination of the tissue is not possible. The objective of this prospective study is to compare the performance of minimally invasive, virtual autopsy, including CT-guided biopsy, with conventional autopsy procedures in a paediatric population. Methods/Design Foetuses, newborns and infants that are referred for autopsy at three different institutions associated with the University of Zurich will be eligible for recruitment. All bodies will be examined with a commercial CT and a 3 Tesla MRI scanner, masked to the results of conventional autopsy. After cross-sectional imaging, CT-guided tissue sampling will be performed by a multifunctional robotic system (Virtobot) allowing for automated post-mortem biopsies. Virtual autopsy results will be classified with regards to the likely final diagnosis and major pathological findings and compared to the results of conventional autopsy, which remains the diagnostic gold standard. Discussion There is an urgent need for the development of alternative post-mortem examination methods, not only as a counselling tool for families and as a quality control measure for clinical diagnosis and treatment but also as an instrument to advance medical knowledge and clinical practice. This interdisciplinary study will determine whether virtual autopsy will narrow the gap in information between non-invasive and traditional autopsy procedures. Trial Registration ClinicalTrials.gov: NCT01888380 PMID:24438163

  19. Renal Cyst Pseudoenhancement: Intraindividual Comparison Between Virtual Monochromatic Spectral Images and Conventional Polychromatic 120-kVp Images Obtained During the Same CT Examination and Comparisons Among Images Reconstructed Using Filtered Back Projection, Adaptive Statistical Iterative Reconstruction, and Model-Based Iterative Reconstruction

    Science.gov (United States)

    Yamada, Yoshitake; Yamada, Minoru; Sugisawa, Koichi; Akita, Hirotaka; Shiomi, Eisuke; Abe, Takayuki; Okuda, Shigeo; Jinzaki, Masahiro

    2015-01-01

    Abstract The purpose of this study was to compare renal cyst pseudoenhancement between virtual monochromatic spectral (VMS) and conventional polychromatic 120-kVp images obtained during the same abdominal computed tomography (CT) examination and among images reconstructed using filtered back projection (FBP), adaptive statistical iterative reconstruction (ASIR), and model-based iterative reconstruction (MBIR). Our institutional review board approved this prospective study; each participant provided written informed consent. Thirty-one patients (19 men, 12 women; age range, 59–85 years; mean age, 73.2 ± 5.5 years) with renal cysts underwent unenhanced 120-kVp CT followed by sequential fast kVp-switching dual-energy (80/140 kVp) and 120-kVp abdominal enhanced CT in the nephrographic phase over a 10-cm scan length with a random acquisition order and 4.5-second intervals. Fifty-one renal cysts (maximal diameter, 18.0 ± 14.7 mm [range, 4–61 mm]) were identified. The CT attenuation values of the cysts as well as of the kidneys were measured on the unenhanced images, enhanced VMS images (at 70 keV) reconstructed using FBP and ASIR from dual-energy data, and enhanced 120-kVp images reconstructed using FBP, ASIR, and MBIR. The results were analyzed using the mixed-effects model and paired t test with Bonferroni correction. The attenuation increases (pseudoenhancement) of the renal cysts on the VMS images reconstructed using FBP/ASIR (least square mean, 5.0/6.0 Hounsfield units [HU]; 95% confidence interval, 2.6–7.4/3.6–8.4 HU) were significantly lower than those on the conventional 120-kVp images reconstructed using FBP/ASIR/MBIR (least square mean, 12.1/12.8/11.8 HU; 95% confidence interval, 9.8–14.5/10.4–15.1/9.4–14.2 HU) (all P < .001); on the other hand, the CT attenuation values of the kidneys on the VMS images were comparable to those on the 120-kVp images. Regardless of the reconstruction algorithm, 70-keV VMS images showed

  20. Fast spin-echo MR imaging of the eye

    International Nuclear Information System (INIS)

    Hosten, N.; Lemke, A.J.; Bornfeld, N.; Wassmuth, R.; Schweiger, U.; Terstegge, K.; Felix, R.

    1996-01-01

    Magnetic resonance imaging of the eye usually includes T2-weighted images both for screening purposes and for characterization of melanoma. Conventional T2-weighted spin-echo (SE) imaging suffers both from long acquisition times and incomplete recovery of the virteous' signal. A fast SE sequence was therefore compared prospectively with conventional sequences in 29 consecutive patients with lesions of the eye. Fast SE images delineated melanoma and other lesions of the eye from vitreous better than conventional T2-weighted images. Image quality and lesion conspicuity were improved on the fast sequence. Whereas melanoma appeared hypointense to vitreous on both types of images, subretinal effusion was hypointense on fast images and hyperintense on conventional T2-weighted images. Ghosting of the globe, which, however, did not decrease diagnostic value, was more pronounced on fast images. Conventional T2-weighted images may be replaced by fast SE images in MR studies of the eye with a gain in lesion conspicuity and significant time saving. (orig.)

  1. University of California, San Diego (UCSD) Sky Imager Cloud Position Study Field Campaign Report

    Energy Technology Data Exchange (ETDEWEB)

    Kleissl, J. [Univ. of California, San Diego, CA (United States); Urquhart, B. [Univ. of California, San Diego, CA (United States); Ghonima, M. [Univ. of California, San Diego, CA (United States); Dahlin, E. [Univ. of California, San Diego, CA (United States); Nguyen, A. [Univ. of California, San Diego, CA (United States); Kurtz, B. [Univ. of California, San Diego, CA (United States); Chow, C. W. [Univ. of California, San Diego, CA (United States); Mejia, F. A. [Univ. of California, San Diego, CA (United States)

    2016-04-01

    During the University of California, San Diego (UCSD) Sky Imager Cloud Position Study, two University of California, San Diego Sky Imagers (USI) (Figure 1) were deployed the U.S. Department of Energy(DOE)’s Atmospheric Radiation Measurement (ARM) Climate Research Facility Southern Great Plains SGP) research facility. The UCSD Sky Imagers were placed 1.7 km apart to allow for stereographic determination of the cloud height for clouds over approximately 1.5 km. Images with a 180-degree field of view were captured from both systems during daylight hours every 30 seconds beginning on March 11, 2013 and ending on November 4, 2013. The spatial resolution of the images was 1,748 × 1,748, and the intensity resolution was 16 bits using a high-dynamic-range capture process. The cameras use a fisheye lens, so the images are distorted following an equisolid angle projection.

  2. Efficacy of the addition of positive airway pressure to conventional chest physiotherapy in resolution of pleural effusion after drainage: protocol for a randomised controlled trial

    Directory of Open Access Journals (Sweden)

    Elinaldo da Conceição dos Santos

    2015-04-01

    Discussion: Conventional chest physiotherapy and intermittent positive airway pressure breathing are widely indicated for people with pleural effusion and chest drains; however, no studies have evaluated the real benefit of this type of treatment. Our hypothesis is that optimised lung expansion achieved through the application of intermittent positive airway pressure will accelerate the reabsorption of pleural effusion, decrease the duration of chest drainage and respiratory system impairment, reduce the length of hospital stay, and reduce the incidence of pulmonary complications.

  3. Positioning accuracy of the neurotron 1000

    International Nuclear Information System (INIS)

    Cox, Richard S.; Murphy, Martin J.

    1995-01-01

    Purpose: The Neurotron 1000 is a novel treatment machine under development for frameless stereotaxic radiosurgery that consists of a compact X-band accelerator mounted on a robotic arm. The therapy beam is guided to the lesion by an imaging system, which includes two diagnostic x-ray cameras that view the patient during treatment. Patient position and motion are measured by the imaging system and appropriate corrections are communicated in real time to the robotic arm for beam targeting and motion tracking. The three tests reported here measured the pointing accuracy of the therapy beam and the present capability of the imaging guidance system. Materials and Methods: 1) The positioning and pointing test measured the ability of the robotic arm to direct the beam through a test isocenter from arbitrary arm positions. The test isocenter was marked by a small light-sensitive crystal and the beam axis was simulated by a laser. The robot was directed to move the linac to a variety of positions, aiming the laser at the crystal detector from each position. The distance of the beam axis from the crystal was measured for each robot position. 2) The imaging-guidance system was tested by moving phantoms about in the field of view of the camera by precisely known displacements and comparing the guidance system's measurement of the phantom position with the its actual position. 3) The system's overall pointing and tracking capability was measured by an end-to-end test using a dosimetric phantom containing radiochromic film. The phantom was imaged by CT to locate the center of the cubical film package. A set of isocentric robotic paths was calculated to produce a spherical dose distribution at the center of the film package. The phantom with the film was then irradiated by the therapy beam as the robot executed the path, with the imaging system providing the beam targeting directions. Results: 1) The positioning and pointing test was performed for paths consisting of spirals and

  4. Validation of Diagnostic Imaging Based on Repeat Examinations. An Image Interpretation Model

    International Nuclear Information System (INIS)

    Isberg, B.; Jorulf, H.; Thorstensen, Oe.

    2004-01-01

    Purpose: To develop an interpretation model, based on repeatedly acquired images, aimed at improving assessments of technical efficacy and diagnostic accuracy in the detection of small lesions. Material and Methods: A theoretical model is proposed. The studied population consists of subjects that develop focal lesions which increase in size in organs of interest during the study period. The imaging modality produces images that can be re-interpreted with high precision, e.g. conventional radiography, computed tomography, and magnetic resonance imaging. At least four repeat examinations are carried out. Results: The interpretation is performed in four or five steps: 1. Independent readers interpret the examinations chronologically without access to previous or subsequent films. 2. Lesions found on images at the last examination are included in the analysis, with interpretation in consensus. 3. By concurrent back-reading in consensus, the lesions are identified on previous images until they are so small that even in retrospect they are undetectable. The earliest examination at which included lesions appear is recorded, and the lesions are verified by their growth (imaging reference standard). Lesion size and other characteristics may be recorded. 4. Records made at step 1 are corrected to those of steps 2 and 3. False positives are recorded. 5. (Optional) Lesion type is confirmed by another diagnostic test. Conclusion: Applied on subjects with progressive disease, the proposed image interpretation model may improve assessments of technical efficacy and diagnostic accuracy in the detection of small focal lesions. The model may provide an accurate imaging reference standard as well as repeated detection rates and false-positive rates for tested imaging modalities. However, potential review bias necessitates a strict protocol

  5. The position dependent influence that sensitivity correction processing gives the signal-to-noise ratio measurement in parallel imaging

    International Nuclear Information System (INIS)

    Murakami, Koichi; Yoshida, Koji; Yanagimoto, Shinichi

    2012-01-01

    We studied the position dependent influence that sensitivity correction processing gave the signal-to-noise ratio (SNR) measurement of parallel imaging (PI). Sensitivity correction processing that referred to the sensitivity distribution of the body coil improved regional uniformity more than the sensitivity uniformity correction filter with a fixed correction factor. In addition, the position dependent influence to give the SNR measurement in PI was different from the sensitivity correction processing. Therefore, if we divide SNR of the sensitivity correction processing image by SNR of the original image in each pixel and calculate SNR ratio, we can show the position dependent influence that sensitivity correction processing gives the SNR measurement in PI. It is with an index of the sensitivity correction processing precision. (author)

  6. Image Watermarking Scheme for Specifying False Positive Probability and Bit-pattern Embedding

    Science.gov (United States)

    Sayama, Kohei; Nakamoto, Masayoshi; Muneyasu, Mitsuji; Ohno, Shuichi

    This paper treats a discrete wavelet transform(DWT)-based image watermarking with considering the false positive probability and bit-pattern embedding. We propose an iterative embedding algorithm of watermarking signals which are K sets pseudo-random numbers generated by a secret key. In the detection, K correlations between the watermarked DWT coefficients and watermark signals are computed by using the secret key. L correlations are made available for the judgment of the watermark presence with specified false positive probability, and the other K-L correlations are corresponding to the bit-pattern signal. In the experiment, we show the detection results with specified false positive probability and the bit-pattern recovery, and the comparison of the proposed method against JPEG compression, scaling down and cropping.

  7. Medan Convention & Exhibition Center (Arsitektur Ekspresionisme)

    OpenAIRE

    Iskandar, Nurul Auni

    2015-01-01

    Medan is one of the third largest city in Indonesia, which is currently being developed, and a city with lots of activities. In the city of Medan has a high investment opportunities for a convention, because of its strategic position in Southeast Asia and also supported by the facility and the potential for tourism in North Sumatra, Medan city has the potential for industrial MICE (Meeting, Incentive, Conference, Exhibition). The construction of Medan Convention & Exhibition Cente...

  8. Incorporating positive body image into the treatment of eating disorders: A model for attunement and mindful self-care.

    Science.gov (United States)

    Cook-Cottone, Catherine P

    2015-06-01

    This article provides a model for understanding the role positive body image can play in the treatment of eating disorders and methods for guiding patients away from symptoms and toward flourishing. The Attuned Representational Model of Self (Cook-Cottone, 2006) and a conceptual model detailing flourishing in the context of body image and eating behavior (Cook-Cottone et al., 2013) are discussed. The flourishing inherent in positive body image comes hand-in-hand with two critical ways of being: (a) having healthy, embodied awareness of the internal and external aspects of self (i.e., attunement) and (b) engaging in mindful self-care. Attunement and mindful self-care thus are considered as potential targets of actionable therapeutic work in the cultivation of positive body image among those with disordered eating. For context, best-practices in eating disorder treatment are also reviewed. Limitations in current research are detailed and directions for future research are explicated. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Postoperative Spondylodiscitis and Epidural Abscess Becoming Visible on Magnetic Resonance Imaging before Positive Laboratory Tests

    Directory of Open Access Journals (Sweden)

    Aysin Pourbagher

    2015-03-01

    Full Text Available Post operative disc space infection is relatively uncommon. The incidence of postoperative disc space infection is 0.21%-3.6% in association with all vertebral surgical procedures. Surgery causes a variety of neuroendocrine and metabolic responses which generally results in immunosupression. Clinical results of immunosupression include delayed wound healing and septic complications. In this article, we report magnetic resonance imaging findings of a case with spondylodiscitis and spinal epidural abscess in which the imaging findings were apparent before the infection and inflammation related laboratory findings laboratory findings become positive. She has a history of surgery due to lumbar herniated disc a month. She was complaining of back and left leg pain. We performed contrast-enhanced MR imaging. MR imaging showed post operative changes at level L5 and S1. There was contrast enhancement at the level of the surgical gap in the posterior paravertebral muscles. MR imaging may help to differentiate postoperative spondylodiscitis and epidural abscess from early postoperative changes even before the laboratory tests appearing positive. In our case, surgery induced immunosupression may cause the infection and inflammation related laboratory findings being within normal limits at the beginning. [Cukurova Med J 2015; 40(Suppl 1: 97-101

  10. Evaluation of average glandular dose in digital and conventional systems of the mammography

    International Nuclear Information System (INIS)

    Xavier, Aline C.S.; Barros, Vinicius S.M.; Khoury, Hellen J.

    2014-01-01

    Mammography is currently the most effective method of diagnosis and detection of breast pathologies. The main interest in this kid of exam comes from the high incidence rate of breast cancer and necessity of high quality images for accurate diagnosis. Digital mammography systems have several advantages compared to conventional systems, however the use of digital imaging systems is not always integrated to an image acquisition protocol. Therefore, it is questionable if digital systems truly reduce the dose received by the patient, because many times is introduced in the clinics without optimization of the image acquisition protocols. The aim of this study is to estimate the value of incident air Kerma and average glandular dose (AGD) in patients undergoing conventional and digital mammography systems in Recife. This study was conducted with 650 patients in three hospitals. The value of incident air Kerma was estimated from the measurement of the yield of equipment and irradiation parameters used for each patient. From these results and using the methodology proposed by Dance et al. the value of the average glandular dose was calculated. The results obtained show that the lowest value of AGD was found with conventional screen-film system, indicating that the parameters for image acquisition with digital systems are not optimized. It was also observed that the institutions with digital systems use lower breast compression values than the conventional. (author)

  11. Imaging of the brain in the HIV-positive child

    International Nuclear Information System (INIS)

    Safriel, Y.I.

    2000-01-01

    The prevalence of human immune-deficiency virus (HIV) infection around the world, coupled with increasing population movement, make it likely that many physicians will treat HIV-infected patients. New treatment protocols for the specific manifestations of acquired immune-deficiency syndrome (AIDS) make distinguishing the different neurological diseases of great importance. The pattern of disease in children differs from those of adults both in its distribution and etiology. This article encapsulates the salient aspects relating to the imaging of the brain in HIV-positive children, paying particular attention to recent advances and the different features of the various pathological conditions affecting the HIV-infected brain in children. (orig.)

  12. Positioning of electrode plane systematically influences EIT imaging.

    Science.gov (United States)

    Krueger-Ziolek, Sabine; Schullcke, Benjamin; Kretschmer, Jörn; Müller-Lisse, Ullrich; Möller, Knut; Zhao, Zhanqi

    2015-06-01

    Up to now, the impact of electrode positioning on electrical impedance tomography (EIT) had not been systematically analyzed due to the lack of a reference method. The aim of the study was to determine the impact of electrode positioning on EIT imaging in spontaneously breathing subjects at different ventilation levels with our novel lung function measurement setup combining EIT and body plethysmography. EIT measurements were conducted in three transverse planes between the 3rd and 4th intercostal space (ICS), at the 5th ICS and between the 6th and 7th ICS (named as cranial, middle and caudal) on 12 healthy subjects. Pulmonary function tests were performed simultaneously by body plethysmography to determine functional residual capacity (FRC), vital capacity (VC), tidal volume (VT), expiratory reserve volume (ERV), and inspiratory reserve volume (IRV). Ratios of impedance changes and body plethysmographic volumes were calculated for every thorax plane (ΔIERV/ERV, ΔIVT/VT and ΔIIRV/IRV). In all measurements of a subject, FRC values and VC values differed ≤5%, which confirmed that subjects were breathing at comparable end-expiratory levels and with similar efforts. In the cranial thorax plane the normalized ΔIERV/ERV ratio in all subjects was significantly higher than the normalized ΔIIRV/IRV ratio whereas the opposite was found in the caudal chest plane. No significant difference between the two normalized ratios was found in the middle thoracic plane. Depending on electrode positioning, impedance to volume ratios may either increase or decrease in the same lung condition, which may lead to opposite clinical decisions.

  13. Ultrasound elastography as an adjuvant to conventional ultrasound in the preoperative assessment of axillary lymph nodes in suspected breast cancer: A pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, K., E-mail: kathryn.taylor@addenbrookes.nhs.uk [Department of Radiology, Cambridge Breast Unit, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom); O' Keeffe, S.; Britton, P.D.; Wallis, M.G. [Department of Radiology, Cambridge Breast Unit, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom); Treece, G.M.; Housden, J. [Department of Engineering, University of Cambridge, Cambridge (United Kingdom); Parashar, D.; Bond, S. [Cambridge Cancer Trials Centre, Department of Oncology, University of Cambridge, Addenbrookes Hospital, Cambridge (United Kingdom); Cambridge Hub in Trials Methodology Research, MRC Biostatics Unit, University Forvie Site, Cambridge (United Kingdom); Sinnatamby, R. [Department of Radiology, Cambridge Breast Unit, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom)

    2011-11-15

    Aims: To compare the performance of ultrasound elastography with conventional ultrasound in the assessment of axillary lymph nodes in suspected breast cancer and whether ultrasound elastography as an adjunct to conventional ultrasound can increase the sensitivity of conventional ultrasound used alone. Materials and methods: Fifty symptomatic women with a sonographic suspicion for breast cancer underwent ultrasound elastography of the ipsilateral axilla concurrent with conventional ultrasound being performed as part of triple assessment. Elastograms were visually scored, strain measurements calculated and node area and perimeter measurements taken. Theoretical biopsy cut points were selected. The sensitivity, specificity, positive predictive value (PPV), and negative predictive values (NPV) were calculated and receiver operating characteristic (ROC) analysis was performed and compared for elastograms and conventional ultrasound images with surgical histology as the reference standard. Results: The mean age of the women was 57 years. Twenty-nine out of 50 of the nodes were histologically negative on surgical histology and 21 were positive. The sensitivity, specificity, PPV, and NPV for conventional ultrasound were 76, 78, 70, and 81%, respectively; 90, 86, 83, and 93%, respectively, for visual ultrasound elastography; and for strain scoring, 100, 48, 58 and 100%, respectively. There was no significant difference between any of the node measurements Conclusions: Initial experience with ultrasound elastography of axillary lymph nodes, showed that it is more sensitive than conventional ultrasound in detecting abnormal nodes in the axilla in cases of suspected breast cancer. The specificity remained acceptable and ultrasound elastography used as an adjunct to conventional ultrasound has the potential to improve the performance of conventional ultrasound alone.

  14. Generalized internal multiple imaging

    KAUST Repository

    Zuberi, M. A. H.

    2014-08-05

    Internal multiples deteriorate the image when the imaging procedure assumes only single scattering, especially if the velocity model does not have sharp contrasts to reproduce such scattering in the Green’s function through forward modeling. If properly imaged, internal multiples (internally scattered energy) can enhance the seismic image. Conventionally, to image internal multiples, accurate, sharp contrasts in the velocity model are required to construct a Green’s function with all the scattered energy. As an alternative, we have developed a generalized internal multiple imaging procedure that images any order internal scattering using the background Green’s function (from the surface to each image point), constructed from a smooth velocity model, usually used for conventional imaging. For the first-order internal multiples, the approach consisted of three steps, in which we first back propagated the recorded surface seismic data using the background Green’s function, then crosscorrelated the back-propagated data with the recorded data, and finally crosscorrelated the result with the original background Green’s function. This procedure images the contribution of the recorded first-order internal multiples, and it is almost free of the single-scattering recorded energy. The cost includes one additional crosscorrelation over the conventional single-scattering imaging application. We generalized this method to image internal multiples of any order separately. The resulting images can be added to the conventional single-scattering image, obtained, e.g., from Kirchhoff or reverse-time migration, to enhance the image. Application to synthetic data with reflectors illuminated by multiple scattering (double scattering) demonstrated the effectiveness of the approach.

  15. Multidetector-row CT angiography of hepatic artery: comparison with conventional angiography

    International Nuclear Information System (INIS)

    Kim, Jin Woong; Jeong, Yong Yeon; Yoon, Woong; Kim, Jae Kyu; Park, Jin Gyoon; Seo, Jeong Jin; Kang, Heoung Keun

    2003-01-01

    To determine the usefulness of three-dimensional CT angiography using multidetector-row CT (MD-CT) for delineating the arterial anatomy of the liver. Hepatic arterial three-dimensional CT angiography was performed using MDCT (lightspeed Qx/I; GE medical systems, milwaukee, Wis., U.S.A.) in 45 patients with HCC undergoing conventional angiography for transcatheter hepatic arterial chemoembolization. The scanning parameters during the early arterial phase were 2.5 mm slice thickness, 7.5 mm rotation of table speed, and a pitch of 3. Images were obtained by one radiologist using maximum intensity projection from axial CT images obtained during the early arterial phase. Two radiologists blinded to the findings of conventional angiography independently evaluated the hepatic arterial anatomy and the quality of the images obtained. Compared with conventional angiography, reader A correctly evaluated the hepatic arterial anatomy depicted at three-dimensional CT angiography. Reader B's evaluation was correct in 40 of 45 patients. Interobserver agreement was good (kappa value, 0.73), and both readers assessed the quality of three-dimensional CT angiography as excellent. Three-dimensional CT angiography using MDCT was accurate for delineating the arterial anatomy of the liver, and interobserver agreement was good. The modality may provide, prior to conventional angiography, valuable information regrading a patient's hepatic arterial anatomy

  16. Determination of Optimal Imaging Mode for Ultrasonographic Detection of Subdermal Contraceptive Rods: Comparison of Spatial Compound, Conventional, and Tissue Harmonic Imaging Methods

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Jin; Seo, Kyung; Song, Ho Taek; Park, Ah Young; Kim, Yaena; Yoon, Choon Sik [Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Suh, Jin Suck; Kim, Ah Hyun [Dept. of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Ryu, Jeong Ah [Dept. of Radiology, Guri Hospital, Hanyang University College of Medicine, Guri (Korea, Republic of); Park, Jeong Seon [Dept. of Radiology, Hanyang University Hospital, Hanyang University College of Medicine, Seoul (Korea, Republic of)

    2012-09-15

    To determine which mode of ultrasonography (US), among the conventional, spatial compound, and tissue-harmonic methods, exhibits the best performance for the detection of Implanon with respect to generation of posterior acoustic shadowing (PAS). A total of 21 patients, referred for localization of impalpable Implanon, underwent US, using the three modes with default settings (i.e., wide focal zone). Representative transverse images of the rods, according to each mode for all patients, were obtained. The resulting 63 images were reviewed by four observers. The observers provided a confidence score for the presence of PAS, using a five-point scale ranging from 1 (definitely absent) to 5 (definitely present), with scores of 4 or 5 for PAS being considered as detection. The average scores of PAS, obtained from the three different modes for each observer, were compared using one-way repeated measure ANOVA. The detection rates were compared using a weighted least square method. Statistically, the tissue harmonic mode was significantly superior to the other two modes, when comparing the average scores of PAS for all observers (p < 0.00-1). The detection rate was also highest for the tissue harmonic mode (p < 0.001). Tissue harmonic mode in US appears to be the most suitable in detecting subdermal contraceptive implant rods.

  17. Determination of Optimal Imaging Mode for Ultrasonographic Detection of Subdermal Contraceptive Rods: Comparison of Spatial Compound, Conventional, and Tissue Harmonic Imaging Methods

    International Nuclear Information System (INIS)

    Kim, Sung Jin; Seo, Kyung; Song, Ho Taek; Park, Ah Young; Kim, Yaena; Yoon, Choon Sik; Suh, Jin Suck; Kim, Ah Hyun; Ryu, Jeong Ah; Park, Jeong Seon

    2012-01-01

    To determine which mode of ultrasonography (US), among the conventional, spatial compound, and tissue-harmonic methods, exhibits the best performance for the detection of Implanon with respect to generation of posterior acoustic shadowing (PAS). A total of 21 patients, referred for localization of impalpable Implanon, underwent US, using the three modes with default settings (i.e., wide focal zone). Representative transverse images of the rods, according to each mode for all patients, were obtained. The resulting 63 images were reviewed by four observers. The observers provided a confidence score for the presence of PAS, using a five-point scale ranging from 1 (definitely absent) to 5 (definitely present), with scores of 4 or 5 for PAS being considered as detection. The average scores of PAS, obtained from the three different modes for each observer, were compared using one-way repeated measure ANOVA. The detection rates were compared using a weighted least square method. Statistically, the tissue harmonic mode was significantly superior to the other two modes, when comparing the average scores of PAS for all observers (p < 0.00-1). The detection rate was also highest for the tissue harmonic mode (p < 0.001). Tissue harmonic mode in US appears to be the most suitable in detecting subdermal contraceptive implant rods.

  18. High Energy Resolution Hyperspectral X-Ray Imaging for Low-Dose Contrast-Enhanced Digital Mammography.

    Science.gov (United States)

    Pani, Silvia; Saifuddin, Sarene C; Ferreira, Filipa I M; Henthorn, Nicholas; Seller, Paul; Sellin, Paul J; Stratmann, Philipp; Veale, Matthew C; Wilson, Matthew D; Cernik, Robert J

    2017-09-01

    Contrast-enhanced digital mammography (CEDM) is an alternative to conventional X-ray mammography for imaging dense breasts. However, conventional approaches to CEDM require a double exposure of the patient, implying higher dose, and risk of incorrect image registration due to motion artifacts. A novel approach is presented, based on hyperspectral imaging, where a detector combining positional and high-resolution spectral information (in this case based on Cadmium Telluride) is used. This allows simultaneous acquisition of the two images required for CEDM. The approach was tested on a custom breast-equivalent phantom containing iodinated contrast agent (Niopam 150®). Two algorithms were used to obtain images of the contrast agent distribution: K-edge subtraction (KES), providing images of the distribution of the contrast agent with the background structures removed, and a dual-energy (DE) algorithm, providing an iodine-equivalent image and a water-equivalent image. The high energy resolution of the detector allowed the selection of two close-by energies, maximising the signal in KES images, and enhancing the visibility of details with the low surface concentration of contrast agent. DE performed consistently better than KES in terms of contrast-to-noise ratio of the details; moreover, it allowed a correct reconstruction of the surface concentration of the contrast agent in the iodine image. Comparison with CEDM with a conventional detector proved the superior performance of hyperspectral CEDM in terms of the image quality/dose tradeoff.

  19. Fast spin-echo imaging

    International Nuclear Information System (INIS)

    Mackey, K.; Zoarski, G.; Bentson, J.R.; Lufkin, R.B.; Melki, P.; Jolesz, F.

    1991-01-01

    This paper reports on a partial radio-frequency (RF) echo-planar pulse sequence called contiguous slice fast spin echo (CSFSE) which is undergoing clinical trials for spine MR imaging. In this variation of rapid acquisition relaxation enhanced (RARE) spin-echo imaging, rapid 180 degrees RF pulse generated refocused echoes, producing T2-weighted images in about one-third the time of conventional double-echo technique. Forty patients with suspected pathology of the spine were imaged with conventional double-echo and closely matched CSFSE techniques on a GE Signa 1.5-T Advantage system. Cases were reviewed by two board-certified neuroradiologists. In all cases the CSFSE images were of equal or superior quality compared with those obtained with the conventional double-echo technique. Pathologic processes that were imaged consisted of inflammatory, neoplastic, posttraumatic, and degenerative conditions

  20. CISS MR imaging findings of epidermoid tumor : comparison with spin-echo images

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong Woo; Kim, Hak Jin; Choi, Sang Yoel; Heo, Jin Sam; Jung, Hoon Sik; Lee, Suck Hong; Kim, Byung Soo [Pusan National Univ. College of Medicine, Pusan (Korea, Republic of); Lee, Jong Wha [Ulsan Univ. Hospital, Ulsan (Korea, Republic of)

    1999-03-01

    To evaluate CISS MR imaging findings of epidermoid tumor in comparison with conventional spin-echo images. We studied 6 cases of epidermoid tumor in the subarachnoid space. We used a 1.5T MR unit to obtain CISS images(TR/TE/FA ; 12.3msec/5.9 msec/700) and T1- and T2- weighted spin-echo images. CISS MR imaging findings were evaluated with respect to tumor's signal intensity , contour, and relation with adjacent structures. Conspicuity of the tumor was compared between CISS and spin-echo images. A quantitative analysis was performed by measuring tumor to CSF contrast. In qualitative analysis, three radiologists independently compared CISS image and conventional spin-echo images for visibility of the tumor and graded them into three categories( poor, good, and excellent). Epidermoid tumors were located in the cerebellopontine angle in 4 cases, the prepontine cisstern in 1 case, and the cerebellopontine angle-prepontine cistern in 1 case. The tumors were hyperintense relative to brain parenchyma and hypointense relative to CSF on CISS images, were lobulated, encased adjacent cranial nerve and vessels, and invaginated into brain parenchyma. In qualitative analysis, CISS images showed clear demarcation between tumor and CSF, exact tumor extension, and tumor's relation with cranial nerves and vessels better than conventional spin-echo images. In quantitative analysis, the mean contrast values of tumor to CSF on T1-, T2-weighted images, and CISS images were 0.12, 0.06, and 0.52, respectively. The contrast value for CISS images was significantly higher than that for T1-and T2-weighted images(p<0.05). Epidermoid tumors in the subarachnoid space are better demonstrated on CISS images than on conventional spin-echo images. This special MR sequence can be added as a routine protocol in the diagnosis of subarachnoid epidermoid tumor.

  1. Diagnostic image quality of video-digitized chest images

    International Nuclear Information System (INIS)

    Winter, L.H.; Butler, R.B.; Becking, W.B.; Warnars, G.A.O.; Haar Romeny, B. ter; Ottes, F.P.; Valk, J.-P.J. de

    1989-01-01

    The diagnostic accuracy obtained with the Philips picture archiving and communications subsystem was investigated by means of an observer performance study using receiver operating characteristic (ROC) analysis. The image qualities of conventional films and video digitized images were compared. The scanner had a 1024 x 1024 x 8 bit memory. The digitized images were displayed on a 60 Hz interlaced display monitor 1024 lines. Posteroanterior (AP) roetgenograms of a chest phantom with superimposed simulated interstitial pattern disease (IPD) were produced; there were 28 normal and 40 abnormal films. Normal films were produced by the chest phantom alone. Abnormal films were taken of the chest phantom with varying degrees of superimposed simulated intersitial disease (PND) for an observer performance study, because the results of a simulated interstitial pattern disease study are less likely to be influenced by perceptual capabilities. The conventional films and the video digitized images were viewed by five experienced observers during four separate sessions. Conventional films were presented on a viewing box, the digital images were displayed on the monitor described above. The presence of simulated intersitial disease was indicated on a 5-point ROC certainty scale by each observer. We analyzed the differences between ROC curves derived from correlated data statistically. The mean time required to evaluate 68 digitized images is approximately four times the mean time needed to read the convential films. The diagnostic quality of the video digitized images was significantly lower (at the 5% level) than that of the conventional films (median area under the curve (AUC) of 0.71 and 0.94, respectively). (author). 25 refs.; 2 figs.; 4 tabs

  2. Analysis of image versus position, scale and direction reveals pattern texture anisotropy

    Directory of Open Access Journals (Sweden)

    Roland eLehoucq

    2015-01-01

    Full Text Available Pattern heterogeneities and anisotropies often carry significant physical information. We provide a toolbox which: (i cumulates analysis in terms of position, direction and scale; (ii is as general as possible; (iii is simple and fast to understand, implement, execute and exploit.It consists in dividing the image into analysis boxes at a chosen scale; in each box an ellipse (the inertia tensor is fitted to the signal and thus determines the direction in which the signal is more present. This tensor can be averaged in position and/or be used to study the dependence with scale. This choice is formally linked with Leray transforms and anisotropic wavelet analysis. Such protocol is intutively interpreted and consistent with what the eye detects: relevant scales, local variations in space, priviledged directions. It is fast and parallelizable.Its several variants are adaptable to the user's data and needs. It is useful to statistically characterize anisotropies of 2D or 3D patterns in which individual objects are not easily distinguished, with only minimal pre-processing of the raw image, and more generally applies to data in higher dimensions.It is less sensitive to edge effects, and thus better adapted for a multiscale analysis down to small scale boxes, than pair correlation function or Fourier transform.Easy to understand and implement,it complements more sophisticated methods such as Hough transform or diffusion tensor imaging.We use it on various fracture patterns (sea ice cover, thin sections of granite, granular materials, to pinpoint the maximal anisotropy scales. The results are robust to noise and to user choices. This toolbox could turn also useful for granular materials, hard condensed matter, geophysics, thin films, statistical mechanics, characterisation of networks, fluctuating amorphous systems, inhomogeneous and disordered systems, or medical imaging, among others.

  3. The positive impact of radiologic imaging on high-stage cutaneous squamous cell carcinoma management.

    Science.gov (United States)

    Ruiz, Emily Stamell; Karia, Pritesh S; Morgan, Frederick C; Schmults, Chrysalyne D

    2017-02-01

    There is limited evidence on the utility of radiologic imaging for prognostic staging of cutaneous squamous cell carcinoma (CSCC). Review utilization of radiologic imaging of high-stage CSCCs to evaluate whether imaging impacted management and outcomes. Tumors classified as Brigham and Women's Hospital (BWH) tumor (T) stage T2B or T3 over a 13-year period were reviewed to identify whether imaging was performed and whether results affected treatment. Disease-related outcomes (DRO: local recurrence, nodal metastasis, death from disease) were compared between patients by type of imaging used. 108 high-stage CSCCs in 98 patients were included. Imaging (mostly computed tomography, 79%) was utilized in 45 (46%) patients and management was altered in 16 (33%) patients who underwent imaging. Patients that received no imaging were at higher risk of developing nodal metastases (nonimaging, 30%; imaging, 13%; P = .041) and any DRO (nonimaging, 42%; imaging, 20%; P = .028) compared to the imaging group. Imaging was associated with a lower risk for DRO (subhazard ratio, 0.5; 95% CI 0.2-0.9; P = .046) adjusted for BWH T stage, sex, and location. Single institution retrospective design and changes in technology overtime. Radiologic imaging of high-stage CSCC may influence management and appears to positively impact outcomes. Further prospective studies are needed to establish which patients benefit from imaging. Copyright © 2016 American Academy of Dermatology, Inc. Published by Elsevier Inc. All rights reserved.

  4. Imaging Method Based on Time Reversal Channel Compensation

    Directory of Open Access Journals (Sweden)

    Bing Li

    2015-01-01

    Full Text Available The conventional time reversal imaging (TRI method builds imaging function by using the maximal value of signal amplitude. In this circumstance, some remote targets are missed (near-far problem or low resolution is obtained in lossy and/or dispersive media, and too many transceivers are employed to locate targets, which increases the complexity and cost of system. To solve these problems, a novel TRI algorithm is presented in this paper. In order to achieve a high resolution, the signal amplitude corresponding to focal time observed at target position is used to reconstruct the target image. For disposing near-far problem and suppressing spurious images, combining with cross-correlation property and amplitude compensation, channel compensation function (CCF is introduced. Moreover, the complexity and cost of system are reduced by employing only five transceivers to detect four targets whose number is close to that of transceivers. For the sake of demonstrating the practicability of the proposed analytical framework, the numerical experiments are actualized in both nondispersive-lossless (NDL media and dispersive-conductive (DPC media. Results show that the performance of the proposed method is superior to that of conventional TRI algorithm even under few echo signals.

  5. Heparin as a pharmacologic intervention to induce positive scintiscan in occult gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Chaudhuri, T.K.; Brantly, M.

    1984-01-01

    The value of using heparin as a pharmacologic intervention to induce a positive scintiscan was studied in a patient with chronic occult gastrointestinal bleeding. When all standard diagnostic tests (upper and lower gastrointestinal series, upper and lower endoscopy, and conventional noninterventional Tc-99m RBC imaging) fail to detect and localize gastrointestinal bleeding in a patient who has definite clinical evidence (guaiac positive stool and dropping hemoglobin, hematocrit) of chronic occult gastrointestinal oozing, heparin may be used (with proper precaution) as a last resort to aid in the scintigraphic detection and localization of chronic occult gastrointestinal bleeding

  6. Response of the 'patient dose calibrator' chamber for incident positions and sizes of X-ray fields

    International Nuclear Information System (INIS)

    Oliveira, Cassio M.; Abrantes, Marcos Eugenio S.; Ferreira, Flavia C. Bastos; Lacerda, Marco A. de Souza; Alonso, Thessa C.; Silva, Teogenes A. da; Oliveira, Paulo Marcio C.

    2009-01-01

    The evaluation of patient doses is an important tool for optimizing radiodiagnostic medical procedures with conventional X-ray equipment and for improving the quality of the radiographic image. The Patient Dose Calibrator (PDC) chamber is a dosimetric instrument that is used in the evaluation of the air kerma-area product (P KA ) quantity aiming the reduction of patient doses. The objective this work was to study the P KA variation caused by different field incident positions and sizes of the X-ray beam on the PDC chamber. Results showed that the PDC chamber has repeatability lower than 0.6%, beam position dependence of 3% and linearity response within ± 6%; these characteristics are to be taken into account during evaluation of the radiological protection conditions of conventional x-ray equipment. (author)

  7. SU-E-J-189: Determination of Markerless Lung Tumor Position in Real Time: A Feasibility Study Using a Novel Tomo-Cinegraphy Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yi, B; Hu, E; Yu, C; Lee, M; Lasio, G [Univ. of Maryland School Of Medicine, Baltimore, MD (United States)

    2015-06-15

    Purpose: A Tomo-Cinegraphy (TC) is a method to generate a series of temporal tomographic images from projection images of the on-board imager (OBI) while gantry is moving. It is to test if this technique is useful to determine a lung tumor position during treatments. Methods: Tomographic image via background subtraction, TIBS uses a priori anatomical information from a previous CT scan to isolate a SOI from a planar kV image by factoring out the attenuations by tissues outside the SOI (background). This idea was extended to a TC, which enables to generate tomographic images of same geometry from the projection of different gantry angles and different breathing phases. Projection images of a lung patient for CBCT acquisition are used to generate TC images. A region of interest (ROI) is selected around a tumor adding 2cm margins. Center of mass (COM) of the ROI is traced to determine tumor position for every projection images. Results: Tumor is visible in the TC images while the OBI projections are not. The coordinates of the COMs represent the temporal tumor positions. While, it is not possible to trace the tumor motion using the projection images. A source of time delay is the time to acquire projection images, which is always less than a second. Conclusion: TC allows tracking the tumor positions without fiducial markers in real time for some lung patients, if the projection images are acquired during treatments. Partially supported by NIH R01CA133539.

  8. Radiologists' leading position in image-guided therapy.

    Science.gov (United States)

    Helmberger, Thomas; Martí-Bonmatí, Luis; Pereira, Philippe; Gillams, Alice; Martínez, Jose; Lammer, Johannes; Malagari, Katarina; Gangi, Afshin; de Baere, Thierry; Adam, E Jane; Rasch, Coen; Budach, Volker; Reekers, Jim A

    2013-02-01

    Image-guided diagnostic and therapeutic procedures are related to, or performed under, some kind of imaging. Such imaging may be direct inspection (as in open surgery) or indirect inspection as in endoscopy or laparoscopy. Common to all these techniques is the transformation of optical and visible information to a monitor or the eye of the operator. Image-guided therapy (IGT) differs by using processed imaging data acquired before, during and after a wide range of different imaging techniques. This means that the planning, performing and monitoring, as well as the control of the therapeutic procedure, are based and dependent on the "virtual reality" provided by imaging investigations. Since most of such imaging involves radiology in the broadest sense, there is a need to characterise IGT in more detail. In this paper, the technical, medico-legal and medico-political issues will be discussed. The focus will be put on state-of-the-art imaging, technical developments, methodological and legal requisites concerning radiation protection and licensing, speciality-specific limitations and crossing specialty borders, definition of technical and quality standards, and finally to the issue of awareness of IGT within the medical and public community. The specialty-specific knowledge should confer radiologists with a significant role in the overall responsibility for the imaging-related processes in various non-radiological specialties. These processes may encompass purchase, servicing, quality management, radiation protection and documentation, also taking responsibility for the definition and compliance with the legal requirements regarding all radiological imaging performed by non-radiologists.

  9. Quantitative simultaneous PET-MR imaging

    Science.gov (United States)

    Ouyang, Jinsong; Petibon, Yoann; Huang, Chuan; Reese, Timothy G.; Kolnick, Aleksandra L.; El Fakhri, Georges

    2014-06-01

    Whole-body PET is currently limited by the degradation due to patient motion. Respiratory motion degrades imaging studies of the abdomen. Similarly, both respiratory and cardiac motions significantly hamper the assessment of myocardial ischemia and/or metabolism in perfusion and viability cardiac PET studies. Based on simultaneous PET-MR, we have developed robust and accurate MRI methods allowing the tracking and measurement of both respiratory and cardiac motions during abdominal or cardiac studies. Our list-mode iterative PET reconstruction framework incorporates the measured motion fields into PET emission system matrix as well as the time-dependent PET attenuation map and the position dependent point spread function. Our method significantly enhances the PET image quality as compared to conventional methods.

  10. Positional and morphologic changes of the temporomandibular joint disc using magnetic resonance imaging

    International Nuclear Information System (INIS)

    Ahn, Hyoun Suk; Cho, Su Beom; Koh, Kwang Joon

    2001-01-01

    To evaluate displacement and morphologic changes of the temporomandibular joint (TMJ) disc in patient with internal derangement using magnetic resonance imaging (MRI). One hundred and forty five MR images of TMJs in 73 patients were evaluated. Positional and morphologic changes of the TMJ disc were assessed. Lateral or medial disc displacement was also evaluated on cornal images. Among 63 discs with anterior disc displacement, 37 discs were assessed as a biconcave disc and 21 as a deformed disc. Rotational disc displacement was observed in 35 disc. Anteromedial disc displacement was observed in 29 discs, and anterolateral direction in 6 discs. Among 35 rotational displacement, 5 biconcave discs and 21 deformed discs were observed. Rotational and sideways displacement of TMJ discs were found to be common and an important aspect of internal derangement. This study also suggests that sagittal and coronal images of the TMJ have complementary abilities for an assessment of joint abnormality

  11. Time-resolved PHERMEX image restorations constrained with an additional multiply-exposed image

    International Nuclear Information System (INIS)

    Kruger, R.P.; Breedlove, J.R. Jr.; Trussell, H.J.

    1978-06-01

    There are a number of possible industrial and scientific applications of nanosecond cineradiographs. Although the technology exists to produce closely spaced pulses of x rays for this application, the quality of the time-resolved radiographs is severely limited. The limitations arise from the necessity of using a fluorescent screen to convert the transmitted x rays to light and then using electro-optical imaging systems to gate and to record the images with conventional high-speed cameras. It has been proposed that, in addition to the time-resolved images, a conventional multiply exposed radiograph be obtained. This report uses both PHERMEX and conventional photographic simulations to demonstrate that the additional information supplied by the multiply exposed radiograph can be used to improve the quality of digital image restorations of the time-resolved pictures over what could be achieved with the degraded images alone

  12. Assessment of image quality and low-contrast detectability in abdominal CT of obese patients: comparison of a novel integrated circuit with a conventional discrete circuit detector at different tube voltages.

    Science.gov (United States)

    Euler, A; Heye, T; Kekelidze, M; Bongartz, G; Szucs-Farkas, Z; Sommer, C; Schmidt, B; Schindera, Sebastian T

    2015-03-01

    To compare image quality and low-contrast detectability of an integrated circuit (IC) detector in abdominal CT of obese patients with conventional detector technology at low tube voltages. A liver phantom with 45 lesions was placed in a water container to mimic an obese patient and examined on two different CT systems at 80, 100 and 120 kVp. The systems were equipped with either the IC or conventional detector. Image noise was measured, and the contrast-to-noise-ratio (CNR) was calculated. Low-contrast detectability was assessed independently by three radiologists. Radiation dose was estimated by the volume CT dose index (CTDIvol). The image noise was significantly lower, and the CNR was significantly higher with the IC detector at 80, 100 and 120 kVp, respectively (P = 0.023). The IC detector resulted in an increased lesion detection rate at 80 kVp (38.1 % vs. 17.2 %) and 100 kVp (57.0 % vs. 41.0 %). There was no difference in the detection rate between the IC detector at 100 kVp and the conventional detector at 120 kVp (57.0 % vs. 62.2 %). The CTDIvol at 80, 100 and 120 kVp measured 4.5-5.2, 7.3-7.9 and 9.8-10.2 mGy, respectively. The IC detector at 100 kVp resulted in similar low-contrast detectability compared to the conventional detector with a 120-kVp protocol at a radiation dose reduction of 37 %.

  13. A prospective evaluation of conventional cystography for detection of urine leakage at the vesicourethral anastomosis site after radical prostatectomy based on computed tomography.

    Science.gov (United States)

    Han, K S; Choi, H J; Jung, D C; Park, S; Cho, K S; Joung, J Y; Seo, H K; Chung, J; Lee, K H

    2011-03-01

    To evaluate the diagnostic accuracy of conventional cystography for the detection of urine leakage at the vesicourethral anastomosis (VUA) site after radical prostatectomy based on computed tomography (CT) cystography. Patients who underwent radical prostatectomies at a single tertiary cancer centre were prospectively enrolled. Conventional cystography was routinely performed on postoperative day 7. Non-enhanced pelvic CT images were obtained after retrograde instillation of the same contrast material for a reference standard of urine leakage at the VUA site. Urine leakage was classified as follows: none; a plication abnormality; mild; moderate; and excessive. One hundred and twenty consecutive patients were enrolled. Conventional cystography detected 14 urine leakages, but CT cystography detected 40 urine leakages, which consisted of 28 mild and 12 moderate urine leakages. When using CT cystography as the standard measurement, conventional cystography showed a diagnostic accuracy of 17.8% (5/28) for mild urine leakage and 75% (9/12) for moderate leakage. Of nine patients diagnosed with mild leakage on conventional cystography, four (44.4%) had complicated moderate urine leakages based on CT cystography, requiring prolonged catheterization. The sensitivity, specificity, positive and negative predictive values, and accuracy of conventional cystography were 35, 100, 100, 75.4, and 78.3%, respectively. Conventional cystography is less accurate than CT cystography for diagnosing urine leakage at the VUA site after a radical prostatectomy. The present results suggest that CT cystography is a good choice for diagnostic imaging of urine leakage after radical prostatectomy. Copyright © 2010 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  14. Positioning of electrode plane systematically influences EIT imaging

    International Nuclear Information System (INIS)

    Krueger-Ziolek, Sabine; Schullcke, Benjamin; Kretschmer, Jörn; Möller, Knut; Zhao, Zhanqi; Müller-Lisse, Ullrich

    2015-01-01

    Up to now, the impact of electrode positioning on electrical impedance tomography (EIT) had not been systematically analyzed due to the lack of a reference method. The aim of the study was to determine the impact of electrode positioning on EIT imaging in spontaneously breathing subjects at different ventilation levels with our novel lung function measurement setup combining EIT and body plethysmography. EIT measurements were conducted in three transverse planes between the 3rd and 4th intercostal space (ICS), at the 5th ICS and between the 6th and 7th ICS (named as cranial, middle and caudal) on 12 healthy subjects. Pulmonary function tests were performed simultaneously by body plethysmography to determine functional residual capacity (FRC), vital capacity (VC), tidal volume (VT), expiratory reserve volume (ERV), and inspiratory reserve volume (IRV). Ratios of impedance changes and body plethysmographic volumes were calculated for every thorax plane (ΔI_E_R_V/ERV, ΔI_V_T/VT and ΔI_I_R_V/IRV). In all measurements of a subject, FRC values and VC values differed ≤5%, which confirmed that subjects were breathing at comparable end-expiratory levels and with similar efforts. In the cranial thorax plane the normalized ΔI_E_R_V/ERV ratio in all subjects was significantly higher than the normalized ΔI_I_R_V/IRV ratio whereas the opposite was found in the caudal chest plane. No significant difference between the two normalized ratios was found in the middle thoracic plane. Depending on electrode positioning, impedance to volume ratios may either increase or decrease in the same lung condition, which may lead to opposite clinical decisions. (paper)

  15. A Study on the Effectiveness of the Manufacture of Compensator and Setup Position for Total Body Irradiation Using Computed Tomography-simulator's Images

    International Nuclear Information System (INIS)

    Lee, Woo Suk; Kim, Dae Sup; Park, Seong Ho; Yun, In Ha; Back, Geum Mun; Kim, Jeong Man

    2005-01-01

    We should use a computed tomography-simulator for the body measure and compensator manufacture process was practiced with TBI's positioning in process and to estimate the availability. Patient took position that lied down. and got picture through computed tomography-simulator. This picture transmitted to Somavision and measured about body measure point on the picture. Measurement was done with skin, and used the image to use measure the image about lungs. We decided thickness of compensator through value that was measured by the image. Also, We decided and confirmed position of compensator through image. Finally, We measured dosage with TLD in the treatment department. About thickness at body measure point. we could find difference of 1-2 cm relationship general measure and image measure. General measure and image measure of body length was seen difference of 3-4 cm. Also, we could paint first drawing of compensator through the image. The value of dose measurement used TLD on head, neck, axilla, chest(lungs inclusion), knee region were measured by 92-98% and abdomen, pelvis, inquinal region, feet region were measured by 102-109%. It was useful for TBI's positioning to use an image of computed tomography-simulator in the process. There was not that is difference of body thickness measure point, but measure about length was achieved definitely. Like this, manufacture of various compensator that consider body density if use image is available. Positioning of compensator could be done exactly, and produce easily without shape of compensator is courted Positioning in the treatment department could shortened overall 15 minute time. and reduce compensator manufacture time about 15 minutes.

  16. Spiral CT versus conventional CT in the preoperative assessment of metallic intraocular foreign bodies

    International Nuclear Information System (INIS)

    Prokesch, R.; Bankier, A.; Ba-Ssalamah, A.; Imhof, H.; Lakits, A.; Scholda, C.

    1998-01-01

    Purpose: To compare the effectiveness of spiral CT versus conventional CT in the preoperative assessment of metallic intraocular foreign bodies. Results: All foreign bodies were detected by each scanning modality on the axial and on the reconstructed planes. The quality of the axial images was similar for spiral and conventional CT. The spiral technique provided high-quality reconstructed images which allowed accurate localization of the foreign bodies in all cases. Reconstructions by conventional technique were inadequate for preoperative assessment. The examination time for the total orbital volume was 18 s for spiral CT and 52 s for conventional CT. Radiation dose delivered to the lens was 35 mGy for spiral CT and 56 mGy for conventional CT axial scanning. Conclusion: Spiral CT multiplanar offers several significant advantages for the preoperative assessment of metallic intraocular foreign bodies compared to the conventional CT technique in clinical practice, including short examination time, minimized motion artifacts, reduced radiation exposure, and accurate localization. (orig.) [de

  17. Reconstruction algorithm medical imaging DRR; Algoritmo de construccion de imagenes medicas DRR

    Energy Technology Data Exchange (ETDEWEB)

    Estrada Espinosa, J. C.

    2013-07-01

    The method of reconstruction for digital radiographic Imaging (DRR), is based on two orthogonal images, on the dorsal and lateral decubitus position of the simulation. DRR images are reconstructed with an algorithm that simulates running a conventional X-ray, a single rendition team, beam emitted is not divergent, in this case, the rays are considered to be parallel in the image reconstruction DRR, for this purpose, it is necessary to use all the values of the units (HU) hounsfield of each voxel in all axial cuts that form the study TC, finally obtaining the reconstructed image DRR performing a transformation from 3D to 2D. (Author)

  18. Daily Prostate Volume and Position Monitoring Using Implanted Gold Markers and On-Board Imaging during Radiotherapy

    Directory of Open Access Journals (Sweden)

    Linda Kašaová

    2011-01-01

    Full Text Available Purpose: This study aimed to evaluate prostate volume changes and prostate motions during radiotherapy. Methods: In 2010, twenty-five patients were treated for prostate cancer by external beam radiotherapy with implanted fiducial markers. Coordinates of three gold markers on kilovoltage images were calculated daily. Volume changes in target structure were observed through changes in intermarker distances. Differences in patient position between laser-tattoo alignment and gold marker localization were evaluated. Intrafraction motion was assessed by measuring marker displacement on kilovoltage images acquired before and after fraction delivery. Results: Prostate shrinkage was observed in 60% of patients. The average shrinkage was 7% of the prostate’s initial volume. Corrections after laser-tattoo alignment remained mostly below 1 cm. The difference between marker centroid position on the actual images and the planning images was 2 ± 1 mm on average. The extension of intrafraction movements was 7.6 ± 0.2 mm on average. Conclusions: In our retrospective study, the possibility for prostate volume changes during radiotherapy was revealed. Intrafraction movements turned out to be the limiting factor in safety margin reduction.

  19. Validation of quantitative brain dopamine D2 receptor imaging with a conventional single-head SPET camera

    International Nuclear Information System (INIS)

    Nikkinen, P.; Liewendahl, K.; Savolainen, S.; Launes, J.

    1993-01-01

    Phantom measurements were performed with a conventional single-head single-photon emission tomography (SPET) camera in order to validate the relevance of the basal ganglia/frontal cortex iodine-123 iodobenzamide (IBZM) uptake ratios measured in patients. Inside a cylindrical phantom (diameter 22 cm), two cylinders with a diameter of 3.3 cm were inserted. The activity concentrations of the cylinders ranged from 6.0 to 22.6 kBq/ml and the cylinder/background activity ratios varied from 1.4 to 3.8. From reconstructed SPET images the cylinder/background activity ratios were calculated using three different regions of interest (ROIs). A linear relationship between the measured activity ratio and the true activity ratio was obtained. In patient studies, basal ganglia/frontal cortex IBZM uptake ratios determined from the reconstructed slices using attentuation correction prior to reconstruction were 1.30 ±0.03 in idiopathic Parkinson's disease (n = 9), 1,33 ±0.09 in infantile and juvenile neuronal ceroid lipofuscinosis (n = 7) and 1.34 ±0.05 in narcolepsy (n = 8). Patients with Huntington's disease had significantly lower ratios (1.09 ±0.04, n = 5). The corrected basal ganglia/frontal cortex ratios, determined using linear regression, were about 80 % higher. The use of dual-window scatter correction increased the measured ratios by about 10 %. Although comprehensive correction methods can further improve the resolution in SPET images, the resolution of the SPET system used by us (1.5 - 2 cm) will determine what is achievable in basal ganglia D2 receptor imaging. (orig.)

  20. Validation of quantitative brain dopamine D2 receptor imaging with a conventional single-head SPET camera

    Energy Technology Data Exchange (ETDEWEB)

    Nikkinen, P [Helsinki Univ. (Finland). Dept. of Clinical Chemistry; Liewendahl, K [Helsinki Univ. (Finland). Dept. of Clinical Chemistry; Savolainen, S [Helsinki Univ. (Finland). Dept. of Physics; Launes, J [Helsinki Univ. (Finland). Dept. of Neurology

    1993-08-01

    Phantom measurements were performed with a conventional single-head single-photon emission tomography (SPET) camera in order to validate the relevance of the basal ganglia/frontal cortex iodine-123 iodobenzamide (IBZM) uptake ratios measured in patients. Inside a cylindrical phantom (diameter 22 cm), two cylinders with a diameter of 3.3 cm were inserted. The activity concentrations of the cylinders ranged from 6.0 to 22.6 kBq/ml and the cylinder/background activity ratios varied from 1.4 to 3.8. From reconstructed SPET images the cylinder/background activity ratios were calculated using three different regions of interest (ROIs). A linear relationship between the measured activity ratio and the true activity ratio was obtained. In patient studies, basal ganglia/frontal cortex IBZM uptake ratios determined from the reconstructed slices using attentuation correction prior to reconstruction were 1.30 [+-]0.03 in idiopathic Parkinson's disease (n = 9), 1,33 [+-]0.09 in infantile and juvenile neuronal ceroid lipofuscinosis (n = 7) and 1.34 [+-]0.05 in narcolepsy (n = 8). Patients with Huntington's disease had significantly lower ratios (1.09 [+-]0.04, n = 5). The corrected basal ganglia/frontal cortex ratios, determined using linear regression, were about 80 % higher. The use of dual-window scatter correction increased the measured ratios by about 10 %. Although comprehensive correction methods can further improve the resolution in SPET images, the resolution of the SPET system used by us (1.5 - 2 cm) will determine what is achievable in basal ganglia D2 receptor imaging. (orig.)

  1. STUDY ON MODELING AND VISUALIZING THE POSITIONAL UNCERTAINTY OF REMOTE SENSING IMAGE

    Directory of Open Access Journals (Sweden)

    W. Jiao

    2016-06-01

    Full Text Available It is inevitable to bring about uncertainty during the process of data acquisition. The traditional method to evaluate the geometric positioning accuracy is usually by the statistical method and represented by the root mean square errors (RMSEs of control points. It is individual and discontinuous, so it is difficult to describe the error spatial distribution. In this paper the error uncertainty of each control point is deduced, and the uncertainty spatial distribution model of each arbitrary point is established. The error model is proposed to evaluate the geometric accuracy of remote sensing image. Then several visualization methods are studied to represent the discrete and continuous data of geometric uncertainties. The experiments show that the proposed evaluation method of error distribution model compared with the traditional method of RMSEs can get the similar results but without requiring the user to collect control points as checkpoints, and error distribution information calculated by the model can be provided to users along with the geometric image data. Additionally, the visualization methods described in this paper can effectively and objectively represents the image geometric quality, and also can help users probe the reasons of bringing the image uncertainties in some extent.

  2. Differential impact of multi-focus fan beam collimation with L-mode and conventional systems on the accuracy of myocardial perfusion imaging: Quantitative evaluation using phantoms

    Directory of Open Access Journals (Sweden)

    Tatsunori Saho

    2013-10-01

    Full Text Available Introduction: A novel IQ-SPECTTM method has become widely used in clinical studies. The present study compares the quality of myocardial perfusion images (MPI acquired using the IQ-SPECTTM (IQ-mode,conventional (180° apart: C-mode and L-mode (90° apart: L-mode systems. We assessed spatial resolution, image reproducibility and quantifiability using various physical phantoms. Materials and Methods: SPECT images were acquired using a dual-headed gamma camera with C-mode, L-mode, and IQ-mode acquisition systems from line source, pai and cardiac phantoms containing solutions of 99mTc. The line source phantom was placed in the center of the orbit and at ± 4.0, ± 8.0, ± 12.0, ± 16.0 and ± 20.0 cm off center. We examined quantifiability using the pai phantom comprising six chambers containing 0.0, 0.016, 0.03, 0.045, 0.062, and 0.074 MBq/mLof 99m-Tc and cross-calibrating the SPECT counts. Image resolution and reproducibility were quantified as myocardial wall thickness (MWT and %uptake using polar maps. Results: The full width at half maximum (FWHM of the IQ-mode in the center was increased by 11% as compared with C-mode, and FWHM in the periphery was increased 41% compared with FWHM at the center. Calibrated SPECT counts were essentially the same when quantified using IQ-and C-modes. IQ-SPECT images of MWT were significantly improved (P<0.001 over L-mode, and C-mode SPECT imaging with IQ-mode became increasingly inhomogeneous, both visually and quantitatively (C-mode vs. L-mode, ns; C-mode vs. IQ-mode, P<0.05. Conclusion: Myocardial perfusion images acquired by IQ-SPECT were comparable to those acquired by conventional and L-mode SPECT, but with significantly improved resolution and quality. Our results suggest that IQ-SPECT is the optimal technology for myocardial perfusion SPECT imaging.

  3. The evolving role of new imaging methods in breast screening.

    Science.gov (United States)

    Houssami, Nehmat; Ciatto, Stefano

    2011-09-01

    The potential to avert breast cancer deaths through screening means that efforts continue to identify methods which may enhance early detection. While the role of most new imaging technologies remains in adjunct screening or in the work-up of mammography-detected abnormalities, some of the new breast imaging tests (such as MRI) have roles in screening groups of women defined by increased cancer risk. This paper highlights the evidence and the current role of new breast imaging technologies in screening, focusing on those that have broader application in population screening, including digital mammography, breast ultrasound in women with dense breasts, and computer-aided detection. It highlights that evidence on new imaging in screening comes mostly from non-randomised studies that have quantified test detection capability as adjunct to mammography, or have compared measures of screening performance for new technologies with that of conventional mammography. Two RCTs have provided high-quality evidence on the equivalence of digital and conventional mammography and on outcomes of screen-reading complemented by CAD. Many of these imaging technologies enhance cancer detection but also increase recall and false positives in screening. Copyright © 2011 Elsevier Inc. All rights reserved.

  4. Radiation dose optimisation for conventional imaging in infants and newborns using automatic dose management software: an application of the new 2013/59 EURATOM directive.

    Science.gov (United States)

    Alejo, L; Corredoira, E; Sánchez-Muñoz, F; Huerga, C; Aza, Z; Plaza-Núñez, R; Serrada, A; Bret-Zurita, M; Parrón, M; Prieto-Areyano, C; Garzón-Moll, G; Madero, R; Guibelalde, E

    2018-04-09

    Objective: The new 2013/59 EURATOM Directive (ED) demands dosimetric optimisation procedures without undue delay. The aim of this study was to optimise paediatric conventional radiology examinations applying the ED without compromising the clinical diagnosis. Automatic dose management software (ADMS) was used to analyse 2678 studies of children from birth to 5 years of age, obtaining local diagnostic reference levels (DRLs) in terms of entrance surface air kerma. Given local DRL for infants and chest examinations exceeded the European Commission (EC) DRL, an optimisation was performed decreasing the kVp and applying the automatic control exposure. To assess the image quality, an analysis of high-contrast resolution (HCSR), signal-to-noise ratio (SNR) and figure of merit (FOM) was performed, as well as a blind test based on the generalised estimating equations method. For newborns and chest examinations, the local DRL exceeded the EC DRL by 113%. After the optimisation, a reduction of 54% was obtained. No significant differences were found in the image quality blind test. A decrease in SNR (-37%) and HCSR (-68%), and an increase in FOM (42%), was observed. ADMS allows the fast calculation of local DRLs and the performance of optimisation procedures in babies without delay. However, physical and clinical analyses of image quality remain to be needed to ensure the diagnostic integrity after the optimisation process. Advances in knowledge: ADMS are useful to detect radiation protection problems and to perform optimisation procedures in paediatric conventional imaging without undue delay, as ED requires.

  5. An image guidance system for positioning robotic cochlear implant insertion tools

    Science.gov (United States)

    Bruns, Trevor L.; Webster, Robert J.

    2017-03-01

    Cochlear implants must be inserted carefully to avoid damaging the delicate anatomical structures of the inner ear. This has motivated several approaches to improve the safety and efficacy of electrode array insertion by automating the process with specialized robotic or manual insertion tools. When such tools are used, they must be positioned at the entry point to the cochlea and aligned with the desired entry vector. This paper presents an image guidance system capable of accurately positioning a cochlear implant insertion tool. An optical tracking system localizes the insertion tool in physical space while a graphical user interface incorporates this with patient- specific anatomical data to provide error information to the surgeon in real-time. Guided by this interface, novice users successfully aligned the tool with an mean accuracy of 0.31 mm.

  6. Maximum likelihood positioning for gamma-ray imaging detectors with depth of interaction measurement

    International Nuclear Information System (INIS)

    Lerche, Ch.W.; Ros, A.; Monzo, J.M.; Aliaga, R.J.; Ferrando, N.; Martinez, J.D.; Herrero, V.; Esteve, R.; Gadea, R.; Colom, R.J.; Toledo, J.; Mateo, F.; Sebastia, A.; Sanchez, F.; Benlloch, J.M.

    2009-01-01

    The center of gravity algorithm leads to strong artifacts for gamma-ray imaging detectors that are based on monolithic scintillation crystals and position sensitive photo-detectors. This is a consequence of using the centroids as position estimates. The fact that charge division circuits can also be used to compute the standard deviation of the scintillation light distribution opens a way out of this drawback. We studied the feasibility of maximum likelihood estimation for computing the true gamma-ray photo-conversion position from the centroids and the standard deviation of the light distribution. The method was evaluated on a test detector that consists of the position sensitive photomultiplier tube H8500 and a monolithic LSO crystal (42mmx42mmx10mm). Spatial resolution was measured for the centroids and the maximum likelihood estimates. The results suggest that the maximum likelihood positioning is feasible and partially removes the strong artifacts of the center of gravity algorithm.

  7. Maximum likelihood positioning for gamma-ray imaging detectors with depth of interaction measurement

    Energy Technology Data Exchange (ETDEWEB)

    Lerche, Ch.W. [Grupo de Sistemas Digitales, ITACA, Universidad Politecnica de Valencia, 46022 Valencia (Spain)], E-mail: lerche@ific.uv.es; Ros, A. [Grupo de Fisica Medica Nuclear, IFIC, Universidad de Valencia-Consejo Superior de Investigaciones Cientificas, 46980 Paterna (Spain); Monzo, J.M.; Aliaga, R.J.; Ferrando, N.; Martinez, J.D.; Herrero, V.; Esteve, R.; Gadea, R.; Colom, R.J.; Toledo, J.; Mateo, F.; Sebastia, A. [Grupo de Sistemas Digitales, ITACA, Universidad Politecnica de Valencia, 46022 Valencia (Spain); Sanchez, F.; Benlloch, J.M. [Grupo de Fisica Medica Nuclear, IFIC, Universidad de Valencia-Consejo Superior de Investigaciones Cientificas, 46980 Paterna (Spain)

    2009-06-01

    The center of gravity algorithm leads to strong artifacts for gamma-ray imaging detectors that are based on monolithic scintillation crystals and position sensitive photo-detectors. This is a consequence of using the centroids as position estimates. The fact that charge division circuits can also be used to compute the standard deviation of the scintillation light distribution opens a way out of this drawback. We studied the feasibility of maximum likelihood estimation for computing the true gamma-ray photo-conversion position from the centroids and the standard deviation of the light distribution. The method was evaluated on a test detector that consists of the position sensitive photomultiplier tube H8500 and a monolithic LSO crystal (42mmx42mmx10mm). Spatial resolution was measured for the centroids and the maximum likelihood estimates. The results suggest that the maximum likelihood positioning is feasible and partially removes the strong artifacts of the center of gravity algorithm.

  8. Concept for quantifying the dose from image guided radiotherapy

    International Nuclear Information System (INIS)

    Schneider, Uwe; Hälg, Roger; Besserer, Jürgen

    2015-01-01

    Radiographic image guidance is routinely used for patient positioning in radiotherapy. All radiographic guidance techniques can give a significant radiation dose to the patient. The dose from diagnostic imaging is usually managed by using effective dose minimization. In contrast, image-guided radiotherapy adds the imaging dose to an already high level of therapeutic radiation which cannot be easily managed using effective dose. The purpose of this work is the development of a concept of IGRT dose quantification which allows a comparison of imaging dose with commonly accepted variations of therapeutic dose. It is assumed that dose variations of the treatment beam which are accepted in the spirit of the ALARA convention can also be applied to the additional imaging dose. Therefore we propose three dose categories: Category I: The imaging dose is lower than a 2 % variation of the therapy dose. Category II: The imaging dose is larger than in category I, but lower than the therapy dose variations between different treatment techniques. Category III: The imaging dose is larger than in Category II. For various treatment techniques dose measurements are used to define the dose categories. The imaging devices were categorized according to the measured dose. Planar kV-kV imaging is a category I imaging procedure. kV-MV imaging is located at the edge between category I and II and is for increasing fraction size safely a category I imaging technique. MV-MV imaging is for all imaging technologies a category II procedure. MV fan beam CT for localization is a category I technology. Low dose protocols for kV CBCT are located between category I and II and are for increasing fraction size a category I imaging technique. All other investigated Pelvis-CBCT protocols are category II procedures. Fan beam CT scout views are category I technology. Live imaging modalities are category III for conventional fractionation, but category II for stereotactic treatments. Dose from radiotherapy

  9. Evaluation of conventional imaging performance in a research whole-body CT system with a photon-counting detector array.

    Science.gov (United States)

    Yu, Zhicong; Leng, Shuai; Jorgensen, Steven M; Li, Zhoubo; Gutjahr, Ralf; Chen, Baiyu; Halaweish, Ahmed F; Kappler, Steffen; Yu, Lifeng; Ritman, Erik L; McCollough, Cynthia H

    2016-02-21

    This study evaluated the conventional imaging performance of a research whole-body photon-counting CT system and investigated its feasibility for imaging using clinically realistic levels of x-ray photon flux. This research system was built on the platform of a 2nd generation dual-source CT system: one source coupled to an energy integrating detector (EID) and the other coupled to a photon-counting detector (PCD). Phantom studies were conducted to measure CT number accuracy and uniformity for water, CT number energy dependency for high-Z materials, spatial resolution, noise, and contrast-to-noise ratio. The results from the EID and PCD subsystems were compared. The impact of high photon flux, such as pulse pile-up, was assessed by studying the noise-to-tube-current relationship using a neonate water phantom and high x-ray photon flux. Finally, clinical feasibility of the PCD subsystem was investigated using anthropomorphic phantoms, a cadaveric head, and a whole-body cadaver, which were scanned at dose levels equivalent to or higher than those used clinically. Phantom measurements demonstrated that the PCD subsystem provided comparable image quality to the EID subsystem, except that the PCD subsystem provided slightly better longitudinal spatial resolution and about 25% improvement in contrast-to-noise ratio for iodine. The impact of high photon flux was found to be negligible for the PCD subsystem: only subtle high-flux effects were noticed for tube currents higher than 300 mA in images of the neonate water phantom. Results of the anthropomorphic phantom and cadaver scans demonstrated comparable image quality between the EID and PCD subsystems. There were no noticeable ring, streaking, or cupping/capping artifacts in the PCD images. In addition, the PCD subsystem provided spectral information. Our experiments demonstrated that the research whole-body photon-counting CT system is capable of providing clinical image quality at clinically realistic levels of x

  10. Evaluation of conventional imaging performance in a research whole-body CT system with a photon-counting detector array

    International Nuclear Information System (INIS)

    Yu, Zhicong; Leng, Shuai; Li, Zhoubo; Chen, Baiyu; Yu, Lifeng; McCollough, Cynthia H; Jorgensen, Steven M; Ritman, Erik L; Gutjahr, Ralf; Kappler, Steffen; Halaweish, Ahmed F

    2016-01-01

    This study evaluated the conventional imaging performance of a research whole-body photon-counting CT system and investigated its feasibility for imaging using clinically realistic levels of x-ray photon flux. This research system was built on the platform of a 2nd generation dual-source CT system: one source coupled to an energy integrating detector (EID) and the other coupled to a photon-counting detector (PCD). Phantom studies were conducted to measure CT number accuracy and uniformity for water, CT number energy dependency for high-Z materials, spatial resolution, noise, and contrast-to-noise ratio. The results from the EID and PCD subsystems were compared. The impact of high photon flux, such as pulse pile-up, was assessed by studying the noise-to-tube-current relationship using a neonate water phantom and high x-ray photon flux. Finally, clinical feasibility of the PCD subsystem was investigated using anthropomorphic phantoms, a cadaveric head, and a whole-body cadaver, which were scanned at dose levels equivalent to or higher than those used clinically. Phantom measurements demonstrated that the PCD subsystem provided comparable image quality to the EID subsystem, except that the PCD subsystem provided slightly better longitudinal spatial resolution and about 25% improvement in contrast-to-noise ratio for iodine. The impact of high photon flux was found to be negligible for the PCD subsystem: only subtle high-flux effects were noticed for tube currents higher than 300 mA in images of the neonate water phantom. Results of the anthropomorphic phantom and cadaver scans demonstrated comparable image quality between the EID and PCD subsystems. There were no noticeable ring, streaking, or cupping/capping artifacts in the PCD images. In addition, the PCD subsystem provided spectral information. Our experiments demonstrated that the research whole-body photon-counting CT system is capable of providing clinical image quality at clinically realistic levels of x

  11. Diffusion-weighted imaging in the diagnosis of enterovirus 71 encephalitis

    International Nuclear Information System (INIS)

    Lian, Zhou-yang; Huang, Biao; Liang, Chang-hong; He, Shaoru; Guo, Yuxiong

    2012-01-01

    Background. In the early phase of viral encephalitis, conventional MRI may appear normal. Diffusion-weighted imaging (DWI) is a sensitive tool for detecting early changes in cellular function in the central nervous system. Purpose. To investigate the usefulness of DWI in the diagnosis of enterovirus 71 (EV71) encephalitis, and to determine whether DWI is superior to conventional MR sequences. Material and Methods. MRI scans in 26 patients were retrospectively evaluated for distribution of lesions on T1-weighted images (T1WI), T2-weighted images (T2WI), fluid-attenuated inversion recovery (FLAIR), and DWI. Contrast-to-noise ratios (CNRs) were calculated for all regions on each sequence and differences in the four MRI sequences were assessed using CNRs. Apparent diffusion coefficient (ADC) values were measured for all regions to look for true restriction of diffusion. Results. Fifteen out of 26 cases showed positive findings on MR imaging. The brain stem was involved in 11 patients, cortex and subcortical white matter in four patients. DWI was more sensitive in detecting the abnormalities (89.7%) compared to T2WI (48.7%), FLAIR (41.0%), and T1WI (35.9%), and the positive ratio of DWI was significantly higher compared to other sequences. Furthermore, no significant difference was found between T2WI and FLAIR (P 0.649). The corresponding mean CNRs were 8.73 ± 2.57, 83.59 ± 29.28, 24.22 ± 6.22, and 132.27 ± 78.32 on T1WI, T2WI, FLAIR, and DWI, respectively. The absolute values of CNRs of lesions on DWI were significantly greater than those on other sequences. Conclusion. DWI appears to be more sensitive in detecting EV71 encephalitis than conventional MRI sequences. This capability may improve the accuracy in diagnosing EV71 encephalitis, especially at the early stage

  12. Diffusion-weighted imaging in the diagnosis of enterovirus 71 encephalitis

    Energy Technology Data Exchange (ETDEWEB)

    Lian, Zhou-yang; Huang, Biao; Liang, Chang-hong (Department of Radiology, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China)), Email: cjr.huangbiao@vip.163.com; He, Shaoru; Guo, Yuxiong (Department of Pediatrics, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China))

    2012-03-15

    Background. In the early phase of viral encephalitis, conventional MRI may appear normal. Diffusion-weighted imaging (DWI) is a sensitive tool for detecting early changes in cellular function in the central nervous system. Purpose. To investigate the usefulness of DWI in the diagnosis of enterovirus 71 (EV71) encephalitis, and to determine whether DWI is superior to conventional MR sequences. Material and Methods. MRI scans in 26 patients were retrospectively evaluated for distribution of lesions on T1-weighted images (T1WI), T2-weighted images (T2WI), fluid-attenuated inversion recovery (FLAIR), and DWI. Contrast-to-noise ratios (CNRs) were calculated for all regions on each sequence and differences in the four MRI sequences were assessed using CNRs. Apparent diffusion coefficient (ADC) values were measured for all regions to look for true restriction of diffusion. Results. Fifteen out of 26 cases showed positive findings on MR imaging. The brain stem was involved in 11 patients, cortex and subcortical white matter in four patients. DWI was more sensitive in detecting the abnormalities (89.7%) compared to T2WI (48.7%), FLAIR (41.0%), and T1WI (35.9%), and the positive ratio of DWI was significantly higher compared to other sequences. Furthermore, no significant difference was found between T2WI and FLAIR (P 0.649). The corresponding mean CNRs were 8.73 +- 2.57, 83.59 +- 29.28, 24.22 +- 6.22, and 132.27 +- 78.32 on T1WI, T2WI, FLAIR, and DWI, respectively. The absolute values of CNRs of lesions on DWI were significantly greater than those on other sequences. Conclusion. DWI appears to be more sensitive in detecting EV71 encephalitis than conventional MRI sequences. This capability may improve the accuracy in diagnosing EV71 encephalitis, especially at the early stage

  13. Patient satisfaction with coronary CT angiography, myocardial CT perfusion, myocardial perfusion MRI, SPECT myocardial perfusion imaging and conventional coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Feger, S.; Rief, M.; Zimmermann, E.; Richter, F.; Roehle, R. [Freie Universitaet Berlin, Department of Radiology, Charite - Universitaetsmedizin Berlin Campus Mitte, Humboldt-Universitaet zu Berlin, Berlin (Germany); Dewey, M. [Freie Universitaet Berlin, Department of Radiology, Charite - Universitaetsmedizin Berlin Campus Mitte, Humboldt-Universitaet zu Berlin, Berlin (Germany); Institut fuer Radiologie, Berlin (Germany); Schoenenberger, E. [Medizinische Hochschule Hannover, Department of Medicine, Hannover (Germany)

    2015-07-15

    To evaluate patient acceptance of noninvasive imaging tests for detection of coronary artery disease (CAD), including single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI), stress perfusion magnetic resonance imaging (MRI), coronary CT angiography (CTA) in combination with CT myocardial stress perfusion (CTP), and conventional coronary angiography (CCA). Intraindividual comparison of perception of 48 patients from the CORE320 multicentre multinational study who underwent rest and stress SPECT-MPI with a technetium-based tracer, combined CTA and CTP (both with contrast agent, CTP with adenosine), MRI, and CCA. The analysis was performed by using a validated questionnaire. Patients had significantly more concern prior to CCA than before CTA/CTP (p < 0.001). CTA/CTP was also rated as more comfortable than SPECT-MPI (p = 0.001). Overall satisfaction with CT was superior to that of MRI (p = 0.007). More patients preferred CT (46 %; p < 0.001) as a future diagnostic test. Regarding combined CTA/CTP, CTP was characterised by higher pain levels and an increased frequency of angina pectoris during the examination (p < 0.001). Subgroup analysis showed a higher degree of pain during SPECT-MPI with adenosine stress compared to physical exercise (p = 0.016). All noninvasive cardiac imaging tests are well accepted by patients, with CT being the preferred examination. (orig.)

  14. Effect of Different Tube Potential Settings on Caries Detection using PSP Plate and Conventional Film.

    Science.gov (United States)

    De Melo, Daniela Pita; Cruz, Adriana Dibo; Melo, Saulo Leonardo Sousa; De Farias, Julyanna Filgueiras GonçAlves; Haiter-Neto, Francisco; De Almeida, Solange Maria

    2015-04-01

    To compare intraoral Phosphor Stimulable Plate digital system and intraoral film using different tube settings on incipient proximal caries detection. Five blocks, with five teeth each, were radiographically examined using phosphor plates and F-speed films. The images were acquired in 07 different tube potentials from 50-80 kV. The films were digitized. Three oral radiologists scored the images for the presence of caries using a 5-point rating scale. The areas under ROC curve were calculated. The influence of tube kilovoltage was verified by ANOVA and pair wise comparisons performed using Tukey test. Mean ROC curve areas varied from 0.446-0.628 for digital images and 0.494-0.559 for conventional images. The tube setting of 70 kV presented the best result both for digital and conventional images. Considering the image type separately, 70 kV scored highest followed by 75 and 65 kV for digital images (p=0.084). For conventional image modality, even though 70 kV presented the best result, it did not differ significantly from 80 kV, not differing from 60 and 55 kV, which did not differ from 75, 65 and 50 kV (p=0.53). Phosphor plate digital images seem to be more susceptible to tube setting potential variations then digitized film images.

  15. Effect of Different Tube Potential Settings on Caries Detection using PSP Plate and Conventional Film

    Science.gov (United States)

    Cruz, Adriana Dibo; Melo, Saulo Leonardo Sousa; De Farias, Julyanna Filgueiras GonçAlves; Haiter-Neto, Francisco; De Almeida, Solange Maria

    2015-01-01

    Purpose To compare intraoral Phosphor Stimulable Plate digital system and intraoral film using different tube settings on incipient proximal caries detection. Materials and Methods Five blocks, with five teeth each, were radiographically examined using phosphor plates and F-speed films. The images were acquired in 07 different tube potentials from 50-80 kV. The films were digitized. Three oral radiologists scored the images for the presence of caries using a 5-point rating scale. The areas under ROC curve were calculated. The influence of tube kilovoltage was verified by ANOVA and pair wise comparisons performed using Tukey test. Results Mean ROC curve areas varied from 0.446-0.628 for digital images and 0.494–0.559 for conventional images. The tube setting of 70 kV presented the best result both for digital and conventional images. Considering the image type separately, 70 kV scored highest followed by 75 and 65 kV for digital images (p=0.084). For conventional image modality, even though 70 kV presented the best result, it did not differ significantly from 80 kV, not differing from 60 and 55 kV, which did not differ from 75, 65 and 50 kV (p=0.53). Conclusion Phosphor plate digital images seem to be more susceptible to tube setting potential variations then digitized film images. PMID:26023645

  16. 'Augmented reality' in conventional simulation by projection of 3-D structures into 2-D images. A comparison with virtual methods

    Energy Technology Data Exchange (ETDEWEB)

    Deutschmann, H.; Nairz, O.; Zehentmayr, F.; Fastner, G.; Sedlmayer, F. [Univ. Clinic for Radiotherapy and Radio-Oncology, Salzburg (Austria); radART - Inst. for research and development on Advanced Radiation Technologies at the Paracelsus Medical Univ., Salzburg (Austria); Steininger, P. [radART - Inst. for research and development on Advanced Radiation Technologies at the Paracelsus Medical Univ., Salzburg (Austria); Dept. of Medical Computer Science and Technology, Univ. for Health Sciences, Hall i. T. (Austria); Kopp, P.; Merz, F.; Wurstbauer, K.; Kranzinger, M.; Kametriser, G.; Kopp, M. [Univ. Clinic for Radiotherapy and Radio-Oncology, Salzburg (Austria)

    2008-02-15

    Background and purpose: in this study, a new method is introduced, which allows the overlay of three-dimensional structures, that have been delineated on transverse slices, onto the fluoroscopy from conventional simulators in real time. Patients and methods: setup deviations between volumetric imaging and simulation were visualized, measured and corrected for 701 patient isocenters. Results: comparing the accuracy to mere virtual simulation lacking additional X-ray imaging, a clear benefit of the new method could be shown. On average, virtual prostate simulations had to be corrected by 0.48 cm (standard deviation [SD] 0.38), and those of the breast by 0.67 cm (SD 0.66). Conclusion: the presented method provides an easy way to determine entity-specific safety margins related to patient setup errors upon registration of bony anatomy (prostate 0.9 cm for 90% of cases, breast 1.3 cm). The important role of planar X-ray imaging was clearly demonstrated. The innovation can also be applied to adaptive image-guided radiotherapy (IGRT) protocols. (orig.)

  17. Estimation of Compton Imager Using Single 3D Position-Sensitive LYSO Scintillator: Monte Carlo Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Taewoong; Lee, Hyounggun; Kim, Younghak; Lee, Wonho [Korea University, Seoul (Korea, Republic of)

    2017-07-15

    The performance of a Compton imager using a single three-dimensional position-sensitive LYSO scintillator detector was estimated using a Monte Carlo simulation. The Compton imager consisted of a single LYSO scintillator with a pixelized structure. The size of the scintillator and each pixel were 1.3 × 1.3 × 1.3 cm{sup 3} and 0.3 × 0.3 × 0.3 cm{sup 3}, respectively. The order of γ-ray interactions was determined based on the deposited energies in each detector. After the determination of the interaction sequence, various types of reconstruction algorithms such as simple back-projection, filtered back-projection, and list-mode maximum-likelihood expectation maximization (LM-MLEM) were applied and compared with each other in terms of their angular resolution and signal-tonoise ratio (SNR) for several γ-ray energies. The LM-MLEM reconstruction algorithm exhibited the best performance for Compton imaging in maintaining high angular resolution and SNR. The two sources of {sup 137}Cs (662 keV) could be distinguishable if they were more than 17 ◦ apart. The reconstructed Compton images showed the precise position and distribution of various radiation isotopes, which demonstrated the feasibility of the monitoring of nuclear materials in homeland security and radioactive waste management applications.

  18. Intravoxel Incoherent Motion Diffusion Weighted MR Imaging for Monitoring the Instantly Therapeutic Efficacy of Radiofrequency Ablation in Rabbit VX2 Tumors without Evident Links between Conventional Perfusion Weighted Images.

    Directory of Open Access Journals (Sweden)

    Ziyi Guo

    Full Text Available To investigate the intravoxel incoherent motion diffusion weighted imaging (IVIM-DWI as a potential valuable marker to monitor the therapy responses of VX2 to radiofrequency ablation (RF Ablation.The institutional animal care and use committee approved this study. In 10 VX2 tumor-bearing rabbits, IVIM-DWI examinations were performed with a 3.0T imaging unit by using 16 b values from 0 to 800 sec/mm2. The true diffusion coefficient (D, pseudodiffusion coefficient (D* and perfusion fraction (f of tumors were compared between before and instantly after RF Ablation treatment. The differences of D, D* and f and conventional perfusion parameters (from perfusion CT and dynamic enhanced magnetic resonance imaging, DCE-MRI in the coagulation necrosis area, residual unablated area, untreated area, and normal control had been calculated by compared t-test. The correlation between f or D* with perfusion weighted CT including blood flow, BF (milliliter per 100 mL/min, blood volume, BV (milliliter per 100 mL/min, and capillary permeability-surface area, PMB (as a fraction or from DCE-MRI: transfer constant (Ktrans, extra-vascular extra-cellular volume fraction (Ve and reflux constant (Kep values had been analyzed by region-of-interest (ROI methods to calculate Pearson's correlation coefficients.In the ablated necrosis areas, f and D* significantly decreased and D significantly increased, compared with residual unblazed areas or untreated control groups and normal control groups (P < 0.001. The IVIM-DWI derived f parameters showed significant increases in the residual unablated tumor area. There was no significant correlations between f or D* and conventional perfusion parameters.The IVIM-DW derived f, D and D* parameters have the potential to indicate therapy response immediately after RF Ablation treatment, while no significant correlations with classical tumor perfusion metrics were derived from DCE-MRI and perfusion-CT measurements.

  19. Acute cerebral stroke imaging and brain perfusion with the use of high-concentration contrast media

    Energy Technology Data Exchange (ETDEWEB)

    Miles, K.A. [Wesley Research Inst., The Wesley Hospital, Brisbane (Australia); Brighton and Sussex Medical School, Univ. of Sussex, Falmer, Brighton (United Kingdom)

    2003-12-01

    Acute cerebral stroke remains a major cause of death among adults and the emergence of new therapies has created a need for early and rapid imaging at a time when conventional CT is either normal or demonstrates subtle abnormalities that are easy to misinterpret. Perfusion CT uses the temporal changes in cerebral and blood attenuation during a rapid series of images acquired without table movement following an intravenous bolus of contrast medium to generate images of mean transit time (MTT) cerebral blood volume (CBV) and perfusion. Reduced perfusion with preserved CBV is indicative of reversible ischaemia, whereas a matched reduction in perfusion and CBV implies infarction. The CT perfusion imaging can positively identify patients with non-haemorrhagic stroke in the presence of a normal conventional CT, provide an indication as to prognosis and potentially select those patients for whom thrombolysis is appropriate. Perfusion CT offers a powerful adjunct to MDCT based imaging of cerebrovascular disease, but further clinical validation is required. (orig.)

  20. An imaging system for a gamma camera

    International Nuclear Information System (INIS)

    Miller, D.W.; Gerber, M.S.

    1980-01-01

    A detailed description is given of a novel gamma camera which is designed to produce superior images than conventional cameras used in nuclear medicine. The detector consists of a solid state detector (e.g. germanium) which is formed to have a plurality of discrete components to enable 2-dimensional position identification. Details of the electronic processing circuits are given and the problems and limitations introduced by noise are discussed in full. (U.K.)

  1. Diagnosis of thyroid multinodular goiter using diffraction-enhanced imaging

    International Nuclear Information System (INIS)

    Rocha, H.S.; Lopes, R.T.; Valiante, P.M.; Tirao, G.; Mazzaro, I.; Hoennicke, M.G.; Cusatis, C.; Giles, C.

    2005-01-01

    Diffraction-enhanced images (DEI) have been obtained using two silicon crystals. A first channel-cut silicon crystal using the Si(3 3 3) reflection is employed to reduce the divergence of the pre-monochromated Si(1 1 1) beam of the light line to 60 microradian (12 arcsec). A second channel-cut Si(3 3 3) crystal was used as a Bragg analyzer to obtain bright and dark field images by changing its angular position. This technique is ideally suited for soft-tissue imaging or objects with the same absorption coefficient interfaces. DEI was developed at the XRD-2 beamline at the Brazilian Synchrotron (LNLS) in Campinas-Brazil. Feasibility tests on acquired images, which allow the diagnosis of thyroid nodular goiter, were performed. This disease is ordinary. The tissue developed on the cervical area causes compression of the nearby structures and undesirable aesthetic deformities with worldwide distribution. DEI of the tissues were taken to observe their morphology and to compare with the microscopic analysis (histopathological). This technique allows cutting sections a hundred times thicker than conventional histological techniques allowing a complete vision of the disease morphology. DEI show details not clearly seen with conventional techniques

  2. A real time S-parameter imaging system

    International Nuclear Information System (INIS)

    Naik, P.S.; Cheung, C.K.; Beling, C.D.; Fung, S.

    2005-01-01

    Obtaining a lateral S-parameter image scan from positrons implanted into semiconductor devices can be a helpful research tool both for localizing device structures and in diagnosing defect patterns that could help interpret function. S-parameter images can be obtained by electromagnetically rastering a variable energy positron beam of small spot size across the sample. Here we describe a general hardware and software architecture of relatively low cost that has recently been developed in our laboratory which allows the whole sub-surface S-parameter image of a sample or device to be obtained in real time. This system has the advantage over more conventional sequential scanning techniques of allowing the operator to terminate data collection once the quality of the image is deemed sufficient. As an example of the usefulness of this type of imaging architecture, S-parameter images of a representative sample are presented at two different position implantation energies. (author)

  3. Radiologists' leading position in image-guided therapy

    NARCIS (Netherlands)

    Helmberger, Thomas; Martí-Bonmatí, Luis; Pereira, Philippe; Gillams, Alice; Martínez, Jose; Lammer, Johannes; Malagari, Katarina; Gangi, Afshin; de Baere, Thierry; Adam, E. Jane; Rasch, Coen; Budach, Volker; Reekers, Jim A.

    2013-01-01

    Image-guided diagnostic and therapeutic procedures are related to, or performed under, some kind of imaging. Such imaging may be direct inspection (as in open surgery) or indirect inspection as in endoscopy or laparoscopy. Common to all these techniques is the transformation of optical and visible

  4. Assessment of image quality and low-contrast detectability in abdominal CT of obese patients: comparison of a novel integrated circuit with a conventional discrete circuit detector at different tube voltages

    Energy Technology Data Exchange (ETDEWEB)

    Euler, A.; Heye, T.; Kekelidze, M.; Bongartz, G.; Schindera, Sebastian T. [University of Basel Hospital, Clinic of Radiology and Nuclear Medicine, Basel (Switzerland); Szucs-Farkas, Z. [Hospital Centre of Biel, Institute of Radiology, Biel (Switzerland); Sommer, C. [University Hospital, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Schmidt, B. [Siemens Healthcare Sector, Forchheim (Germany)

    2014-10-15

    To compare image quality and low-contrast detectability of an integrated circuit (IC) detector in abdominal CT of obese patients with conventional detector technology at low tube voltages. A liver phantom with 45 lesions was placed in a water container to mimic an obese patient and examined on two different CT systems at 80, 100 and 120 kVp. The systems were equipped with either the IC or conventional detector. Image noise was measured, and the contrast-to-noise-ratio (CNR) was calculated. Low-contrast detectability was assessed independently by three radiologists. Radiation dose was estimated by the volume CT dose index (CTDI{sub vol}). The image noise was significantly lower, and the CNR was significantly higher with the IC detector at 80, 100 and 120 kVp, respectively (P = 0.023). The IC detector resulted in an increased lesion detection rate at 80 kVp (38.1 % vs. 17.2 %) and 100 kVp (57.0 % vs. 41.0 %). There was no difference in the detection rate between the IC detector at 100 kVp and the conventional detector at 120 kVp (57.0 % vs. 62.2 %). The CTDI{sub vol} at 80, 100 and 120 kVp measured 4.5-5.2, 7.3-7.9 and 9.8-10.2 mGy, respectively. The IC detector at 100 kVp resulted in similar low-contrast detectability compared to the conventional detector with a 120-kVp protocol at a radiation dose reduction of 37 %. (orig.)

  5. Open-top selective plane illumination microscope for conventionally mounted specimens.

    Science.gov (United States)

    McGorty, Ryan; Liu, Harrison; Kamiyama, Daichi; Dong, Zhiqiang; Guo, Su; Huang, Bo

    2015-06-15

    We have developed a new open-top selective plane illumination microscope (SPIM) compatible with microfluidic devices, multi-well plates, and other sample formats used in conventional inverted microscopy. Its key element is a water prism that compensates for the aberrations introduced when imaging at 45 degrees through a coverglass. We have demonstrated its unique high-content imaging capability by recording Drosophila embryo development in environmentally-controlled microfluidic channels and imaging zebrafish embryos in 96-well plates. We have also shown the imaging of C. elegans and moving Drosophila larvae on coverslips.

  6. Comparison of transaxial source images and 3-plane, thin-slab maximal intensity projection images for the diagnosis of coronary artery stenosis with using ECG-gated cardiac CT

    International Nuclear Information System (INIS)

    Choi, Jin Woo; Seo, Joon Beom; Do, Kyung Hyun

    2006-01-01

    We wanted to compare the transaxial source images with the optimized three plane, thin-slab maximum intensity projection (MIP) images from electrocardiographic (ECG)-gated cardiac CT for their ability to detect hemodynamically significant stenosis (HSS), and we did this by means of performing a receiver operating characteristic (ROC) analysis. Twenty-eight patients with a heart rate less than 66 beats per minute and who were undergoing both retrospective ECG-gated cardiac CT and conventional coronary angiography were included in this study. The contrast-enhanced CT scans were obtained with a collimation of 16 x 0.75-mm and a rotation time of 420 msec. The tranaxial images were reconstructed at the mid-diastolic phase with a 1-mm slice thickness and a 0.5-mm increment. Using the transaxial images, the slab MIP images were created with a 4-mm thickness and a 2-mm increment, and they covered the entire heart in the horizontal long axis (4 chamber view), in the vertical long axis (2 chamber view) and in the short axis. The transaxial images and MIP images were independently evaluated for their ability to detect HSS. Conventional coronary angiograms of the same study group served as the standard of reference. Four radiologists were requested to rank each image with using a five-point scale (1 = definitely negative, 2 = probably negative, 3 = indeterminate, 4 = probably positive, and 5 definitely positive) for the presence of HSS; the data were then interpreted using ROC analysis. There was no statistical difference in the area under the ROC curve between transaxial images and MIP images for the detection of HSS (0.8375 and 0.8708, respectively; ρ > 0.05). The mean reading time for the transaxial source images and the MIP images was 116 and 126.5 minutes, respectively. The diagnostic performance of the MIP images for detecting HSS of the coronary arteries is acceptable and this technique's ability to detect HSS is comparable to that of the transaxial source images

  7. Enhanced Imaging of Building Interior for Portable MIMO Through-the-wall Radar

    Science.gov (United States)

    Song, Yongping; Zhu, Jiahua; Hu, Jun; Jin, Tian; Zhou, Zhimin

    2018-01-01

    Portable multi-input multi-output (MIMO) radar system is able to imaging the building interior through aperture synthesis. However, significant grating lobes are invoked in the directly imaging results, which may deteriorate the imaging quality of other targets and influence the detail information extraction of imaging scene. In this paper, a two-stage coherence factor (CF) weighting method is proposed to enhance the imaging quality. After obtaining the sub-imaging results of each spatial sampling position using conventional CF approach, a window function is employed to calculate the proposed “enhanced CF” adaptive to the spatial variety effect behind the wall for the combination of these sub-images. The real data experiment illustrates the better performance of proposed method on grating lobes suppression and imaging quality enhancement compare to the traditional radar imaging approach.

  8. Expanded image database of pistachio x-ray images and classification by conventional methods

    Science.gov (United States)

    Keagy, Pamela M.; Schatzki, Thomas F.; Le, Lan Chau; Casasent, David P.; Weber, David

    1996-12-01

    In order to develop sorting methods for insect damaged pistachio nuts, a large data set of pistachio x-ray images (6,759 nuts) was created. Both film and linescan sensor images were acquired, nuts dissected and internal conditions coded using the U.S. Grade standards and definitions for pistachios. A subset of 1199 good and 686 insect damaged nuts was used to calculate and test discriminant functions. Statistical parameters of image histograms were evaluated for inclusion by forward stepwise discrimination. Using three variables in the discriminant function, 89% of test set nuts were correctly identified. Comparable data for 6 human subjects ranged from 67 to 92%. If the loss of good nuts is held to 1% by requiring a high probability to discard a nut as insect damaged, approximately half of the insect damage present in clean pistachio nuts may be detected and removed by x-ray inspection.

  9. Block matching sparsity regularization-based image reconstruction for incomplete projection data in computed tomography

    Science.gov (United States)

    Cai, Ailong; Li, Lei; Zheng, Zhizhong; Zhang, Hanming; Wang, Linyuan; Hu, Guoen; Yan, Bin

    2018-02-01

    In medical imaging many conventional regularization methods, such as total variation or total generalized variation, impose strong prior assumptions which can only account for very limited classes of images. A more reasonable sparse representation frame for images is still badly needed. Visually understandable images contain meaningful patterns, and combinations or collections of these patterns can be utilized to form some sparse and redundant representations which promise to facilitate image reconstructions. In this work, we propose and study block matching sparsity regularization (BMSR) and devise an optimization program using BMSR for computed tomography (CT) image reconstruction for an incomplete projection set. The program is built as a constrained optimization, minimizing the L1-norm of the coefficients of the image in the transformed domain subject to data observation and positivity of the image itself. To solve the program efficiently, a practical method based on the proximal point algorithm is developed and analyzed. In order to accelerate the convergence rate, a practical strategy for tuning the BMSR parameter is proposed and applied. The experimental results for various settings, including real CT scanning, have verified the proposed reconstruction method showing promising capabilities over conventional regularization.

  10. Islamic and conventional bank market value: Manager behavior and investor sentiment

    Directory of Open Access Journals (Sweden)

    Mouna Abdelhedi-Zouch

    2016-12-01

    Full Text Available This paper studies the effect of bank manager behavior and investor behavior on market value of Islamic and conventional banks in the Middle East and North Africa region. Firstly, our analysis denoted the positive effect of discretionary behavior of manager on both types of banks on share prices since discretionary behavior transmits to investor a positive signal of future earnings’ prospects. Also, we find that the conventional bank stock prices response is very high to negative signal compared with positive signal. This result is explained by prospect theory and loss aversion bias which specified that individuals are more sensitive to losses than gains of same magnitude. In particular, we discover that the negative effect of non-discretionary behavior is much lower on Islamic bank value since investors give more confidence to Islamic bank because they are motivated by the idea that Islamic banks are safer than conventional banks. Secondly, the results show that investor sentiment affects significantly both bank market prices. Thus, both Islamic and conventional banks’ market value depends similarly on manager and investor behavior. The implication of this paper is that Islamic bank concentrations reveal a positive effect on their price values because of the recently increased investments in Islamic banks.

  11. Experimental investigations of image quality in X-ray mammography with conventional screen film system (SFS), digital phosphor storage plate in/without magnification technique (CR) and digital CCD-technique (CCD)

    International Nuclear Information System (INIS)

    Schulz-Wendtland, R.; Aichinger, U.; Boehner, C.; Dobritz, M.; Wenkel, E.; Bautz, W.; Saebel, M.

    2001-01-01

    Comparison of image quality in X-ray mammography between conventional film screen film system (SFS), digital phosphor storage plate in and without magnification technique (CR) and digital CCD-technique (CCD). Radiograms of an RMI-mammography phantom were acquired using a conventional screen film system, three digital storage plate systems and two digital systems in CCD-technique. Additionally the radiograms of one digital phosphor storage plate system were post-processed regarding contrast and included in the comparison. The detectability of details was best with the digital mammography in CCD-technique. After confirming these promising results in clinical studies, digital mammography should be able to replace conventional screen film technique. (orig.)

  12. Numerical deconvolution to enhance sharpness and contrast of portal images for radiotherapy patient positioning verification

    International Nuclear Information System (INIS)

    Looe, H.K.; Uphoff, Y.; Poppe, B.; Carl von Ossietzky Univ., Oldenburg; Harder, D.; Willborn, K.C.

    2012-01-01

    The quality of megavoltage clinical portal images is impaired by physical and geometrical effects. This image blurring can be corrected by a fast numerical two-dimensional (2D) deconvolution algorithm implemented in the electronic portal image device. We present some clinical examples of deconvolved portal images and evaluate the clinical advantages achieved by the improved sharpness and contrast. The principle of numerical 2D image deconvolution and the enhancement of sharpness and contrast thereby achieved are shortly explained. The key concept is the convolution kernel K(x,y), the mathematical equivalent of the smearing or blurring of a picture, and the computer-based elimination of this influence. Enhancements of sharpness and contrast were observed in all clinical portal images investigated. The images of fine bone structures were restored. The identification of organ boundaries and anatomical landmarks was improved, thereby permitting a more accurate comparison with the x-ray simulator radiographs. The visibility of prostate gold markers is also shown to be enhanced by deconvolution. The blurring effects of clinical portal images were eliminated by a numerical deconvolution algorithm that leads to better image sharpness and contrast. The fast algorithm permits the image blurring correction to be performed in real time, so that patient positioning verification with increased accuracy can be achieved in clinical practice. (orig.)

  13. Numerical deconvolution to enhance sharpness and contrast of portal images for radiotherapy patient positioning verification

    Energy Technology Data Exchange (ETDEWEB)

    Looe, H.K.; Uphoff, Y.; Poppe, B. [Pius Hospital, Oldenburg (Germany). Clinic for Radiation Therapy; Carl von Ossietzky Univ., Oldenburg (Germany). WG Medical Radiation Physics; Harder, D. [Georg August Univ., Goettingen (Germany). Medical Physics and Biophysics; Willborn, K.C. [Pius Hospital, Oldenburg (Germany). Clinic for Radiation Therapy

    2012-02-15

    The quality of megavoltage clinical portal images is impaired by physical and geometrical effects. This image blurring can be corrected by a fast numerical two-dimensional (2D) deconvolution algorithm implemented in the electronic portal image device. We present some clinical examples of deconvolved portal images and evaluate the clinical advantages achieved by the improved sharpness and contrast. The principle of numerical 2D image deconvolution and the enhancement of sharpness and contrast thereby achieved are shortly explained. The key concept is the convolution kernel K(x,y), the mathematical equivalent of the smearing or blurring of a picture, and the computer-based elimination of this influence. Enhancements of sharpness and contrast were observed in all clinical portal images investigated. The images of fine bone structures were restored. The identification of organ boundaries and anatomical landmarks was improved, thereby permitting a more accurate comparison with the x-ray simulator radiographs. The visibility of prostate gold markers is also shown to be enhanced by deconvolution. The blurring effects of clinical portal images were eliminated by a numerical deconvolution algorithm that leads to better image sharpness and contrast. The fast algorithm permits the image blurring correction to be performed in real time, so that patient positioning verification with increased accuracy can be achieved in clinical practice. (orig.)

  14. The value of magnetic resonance imaging for the detection of the bleeding source in non-traumatic intracerebral haemorrhages: a comparison with conventional digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Lummel, Nina; Lutz, Juergen; Brueckmann, Hartmut; Linn, Jennifer [University of Munich, Department of Neuroradiology, Munich (Germany)

    2012-07-15

    Conventional digital subtraction angiography (DSA) is currently regarded as the gold standard in detecting underlying vascular pathologies in patients with intracerebral haemorrhages (ICH). However, the use of magnetic resonance imaging (MRI) in the diagnostic workup of ICHs has considerably increased in recent years. Our aim was to evaluate the diagnostic accuracy and yield of MRI for the detection of the underlying aetiology in ICH patients. Sixty-seven consecutive patients with an acute ICH who underwent MRI (including magnetic resonance angiography (MRA) and DSA during their diagnostic workup) were included in the study. Magnetic resonance images were retrospectively analysed by two independent neuroradiologists to determine the localisation and cause of the ICH. DSA was used as a reference standard. In seven patients (10.4%), a DSA-positive vascular aetiology was present (one aneurysm, four arteriovenous malformations, one dural arteriovenous fistula and one vasculitis). All of these cases were correctly diagnosed by both readers on MRI. In addition, MRI revealed the following probable bleeding causes in 39 of the 60 DSA-negative patients: cerebral amyloid angiopathy (17), cavernoma (9), arterial hypertension (8), haemorrhagic transformation of an ischaemic infarction (3) and malignant brain tumour with secondary ICH (2). Performing MRI with MRA proved to be an accurate diagnostic tool in detecting vascular malformations in patients with ICH. In addition, MRI provided valuable information regarding DSA-negative ICH causes, and thus had a high diagnostic yield in ICH patients. (orig.)

  15. Bubble vs conventional continuous positive airway pressure for prevention of extubation failure in preterm very low birth weight infants: a pilot study.

    Science.gov (United States)

    Yadav, Sucheta; Thukral, Anu; Sankar, M Jeeva; Sreenivas, V; Deorari, Ashok K; Paul, Vinod K; Agarwal, Ramesh

    2012-09-01

    To compare the efficacy of bubble and conventional nasal continuous positive airway pressure (CPAP) in preventing extubation failure (EF) in preterm infants. Infants of gestation ≤32 wk and birth weight <1500 g, ready for initial extubation within first wk of life were randomly allocated to either bubble (n = 16) or conventional (n = 16) CPAP. A standardized protocol was used for extubation. Bubble CPAP was delivered by Fischer and Paykel equipment using short binasal prongs and conventional CPAP was delivered by a ventilator using Argyle short binasal prongs. CPAP was initiated at a pressure of 4-6 cm of H(2)O and FiO(2) of 0.4-0.5 and adjusted to maintain normal saturation (90-93%) and comfortable breathing. Primary outcome was EF, defined as need for mechanical ventilation within 72 h of extubation. Baseline characteristics including birth weight (g; 1027 ± 243 vs. 1018 ± 227; p = 0.83), gestation (wk; 28.7 ± 1.8 vs. 28.4 ± 1.6; p = 0.30), infants <28 wk gestation (6 vs. 7, p = 0.72) were comparable between the two groups. Respiratory distress syndrome was the indication for ventilation in 13 (81%) and 14 (87%) infants on bubble CPAP and conventional CPAP groups respectively. (p = 0.99). There was no difference in the EF rates between the bubble (n = 4) and conventional CPAP (n = 9) groups. (RR 0.49; 95% CI 0.20-1.2; p = 0.14). Median time to extubation failure was also comparable between the two groups (h; median [range]: 29 [14-49] vs. 17 [7-28]; p = 0.35). The possibility that bubble CPAP may be associated with reduced EF as suggested in this pilot study requires further investigation in an adequately powered multicentric study.

  16. Accuracy of Ultrasound-Based Image Guidance for Daily Positioning of the Upper Abdomen: An Online Comparison With Cone Beam CT

    International Nuclear Information System (INIS)

    Boda-Heggemann, Judit; Mennemeyer, Philipp; Wertz, Hansjoerg; Riesenacker, Nadja; Kuepper, Beate; Lohr, Frank; Wenz, Frederik

    2009-01-01

    Purpose: Image-guided intensity-modulated radiotherapy can improve protection of organs at risk when large abdominal target volumes are irradiated. We estimated the daily positioning accuracy of ultrasound-based image guidance for abdominal target volumes by a direct comparison of daily imaging obtained with cone beam computed tomography (CBCT). Methods and Materials: Daily positioning (n = 83 positionings) of 15 patients was completed by using ultrasound guidance after an initial CBCT was obtained. Residual error after ultrasound was estimated by comparison with a second CBCT. Ultrasound image quality was visually rated using a scale of 1 to 4. Results: Of 15 patients, 7 patients had good sonographic imaging quality, 5 patients had satisfactory sonographic quality, and 3 patients were excluded because of unsatisfactory sonographic quality. When image quality was good, residual errors after ultrasound were -0.1 ± 3.11 mm in the x direction (left-right; group systematic error M = -0.09 mm; standard deviation [SD] of systematic error, Σ = 1.37 mm; SD of the random error, σ = 2.99 mm), 0.93 ± 4.31 mm in the y direction (superior-inferior, M = 1.12 mm; Σ = 2.96 mm; σ = 3.39 mm), and 0.71 ± 3.15 mm in the z direction (anteroposterior; M = 1.01 mm; Σ = 2.46 mm; σ = 2.24 mm). For patients with satisfactory image quality, residual error after ultrasound was -0.6 ± 5.26 mm in the x (M = 0.07 mm; Σ = 5.67 mm; σ = 4.86 mm), 1.76 ± 4.92 mm in the y (M = 3.54 mm; Σ = 4.1 mm; σ = 5.29 mm), and 1.19 ± 4.75 mm in the z (M = 0.82 mm; Σ = 2.86 mm; σ = 3.05 mm) directions. Conclusions: In patients from whom good sonographic image quality could be obtained, ultrasound improved daily positioning accuracy. In the case of satisfactory image quality, ultrasound guidance improved accuracy compared to that of skin marks only minimally. If sonographic image quality was unsatisfactory, daily CBCT scanning improved treatment accuracy distinctly over that of ultrasound. Use of

  17. Brain imaging with synthetic MR in children: clinical quality assessment

    Energy Technology Data Exchange (ETDEWEB)

    Betts, Aaron M.; Serai, Suraj [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States); Leach, James L.; Jones, Blaise V. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States); University of Cincinnati College of Medicine, Cincinnati, OH (United States); Zhang, Bin [Cincinnati Children' s Hospital Medical Center, Biostatistics and Epidemiology, Cincinnati, OH (United States)

    2016-10-15

    Synthetic magnetic resonance imaging is a quantitative imaging technique that measures inherent T1-relaxation, T2-relaxation, and proton density. These inherent tissue properties allow synthesis of various imaging sequences from a single acquisition. Clinical use of synthetic MR imaging has been described in adult populations. However, use of synthetic MR imaging has not been previously reported in children. The purpose of this study is to report our assessment of diagnostic image quality using synthetic MR imaging in children. Synthetic MR acquisition was obtained in a sample of children undergoing brain MR imaging. Image quality assessments were performed on conventional and synthetic T1-weighted, T2-weighted, and FLAIR images. Standardized linear measurements were performed on conventional and synthetic T2 images. Estimates of patient age based upon myelination patterns were also performed. Conventional and synthetic MR images were evaluated on 30 children. Using a 4-point assessment scale, conventional imaging performed better than synthetic imaging for T1-weighted, T2-weighted, and FLAIR images. When the assessment was simplified to a dichotomized scale, the conventional and synthetic T1-weighted and T2-weighted images performed similarly. However, the superiority of conventional FLAIR images persisted in the dichotomized assessment. There were no statistically significant differences between linear measurements made on T2-weighted images. Estimates of patient age based upon pattern of myelination were also similar between conventional and synthetic techniques. Synthetic MR imaging may be acceptable for clinical use in children. However, users should be aware of current limitations that could impact clinical utility in the software version used in this study. (orig.)

  18. Relationship of condylar position to disc position and morphology

    Energy Technology Data Exchange (ETDEWEB)

    Incesu, L.; Taskaya-Yilmaz, N. E-mail: nergizy@omu.edu.tr; Oeguetcen-Toller, M.; Uzun, E

    2004-09-01

    Introduction/objective: The purpose of this study was to assess whether condylar position, as depicted by magnetic resonance imaging, was an indicator of disc morphology and position. Methods and material: One hundred and twenty two TMJs of 61 patients with temporomandibular joint disorder were examined. Condylar position, disc deformity and degree of anterior disc displacement were evaluated by using magnetic resonance imaging. Results and discussion: Posterior condyle position was found to be the main feature of temporomandibular joints with slight and moderate anterior disc displacement. No statistical significance was found between the condylar position, and reducing and nonreducing disc positions. On the other hand, superior disc position was found to be statistically significant for centric condylar position. Conclusion: It was concluded that posterior condyle position could indicate anterior disc displacement whereas there was no relation between the position of condyle and the disc deformity.

  19. Position Accuracy of Implant Analogs on 3D Printed Polymer versus Conventional Dental Stone Casts Measured Using a Coordinate Measuring Machine.

    Science.gov (United States)

    Revilla-León, Marta; Gonzalez-Martín, Óscar; Pérez López, Javier; Sánchez-Rubio, José Luis; Özcan, Mutlu

    2017-11-17

    To compare the accuracy of implant analog positions on complete edentulous maxillary casts made of either dental stone or additive manufactured polymers using a coordinate measuring machine (CMM). A completely edentulous maxillary model of a patient with 7 implant analogs was obtained. From this model, two types of casts were duplicated, namely conventional dental stone (CDS) using a custom tray impression technique after splinting (N = 5) and polymer cast using additive manufacturing based on the STL file generated. Polymer casts (N = 20; n = 5 per group) were fabricated using 4 different additive manufacturing technologies (multijet printing-MJP1, direct light processing-DLP, stereolithography-SLA, multijet printing-MJP2). CMM was used to measure the correct position of each implant, and distortion was calculated for each system at x-, y-, and z-axes. Measurements were repeated 3 times per specimen in each axis yielding a total of 546 measurements. Data were analyzed using ANOVA, Sheffé tests, and Bonferroni correction (α = 0.05). Compared to CMM, the mean distortion (μm) ranged from 22.7 to 74.9, 23.4 to 49.1, and 11.0 to 85.8 in the x-, y-, and z-axes, respectively. CDS method (x-axis: 37.1; z-axis: 27.62) showed a significant difference compared to DLP on the x-axis (22.7) (p = 0.037) and to MJP1 on the z-axis (11.0) (p = 0.003). Regardless of the cast system, x-axes showed more distortion (42.6) compared to y- (34.6) and z-axes (35.97). Among additive manufacturing technologies, MJP2 presented the highest (64.3 ± 83.6), and MJP1 (21.57 ± 16.3) and DLP (27.07 ± 20.23) the lowest distortion, which was not significantly different from CDS (32.3 ± 22.73) (p > 0.05). For the fabrication of the definitive casts for implant prostheses, one of the multijet printing systems and direct light processing additive manufacturing technologies showed similar results to conventional dental stone. Conventional dental stone casts could be accurately duplicated using some

  20. Comparing near-infrared conventional diffuse reflectance spectroscopy and hyperspectral imaging for determination of the bulk properties of solid samples by multivariate regression: determination of Mooney viscosity and plasticity indices of natural rubber.

    Science.gov (United States)

    Juliano da Silva, Carlos; Pasquini, Celio

    2015-01-21

    Conventional reflectance spectroscopy (NIRS) and hyperspectral imaging (HI) in the near-infrared region (1000-2500 nm) are evaluated and compared, using, as the case study, the determination of relevant properties related to the quality of natural rubber. Mooney viscosity (MV) and plasticity indices (PI) (PI0 - original plasticity, PI30 - plasticity after accelerated aging, and PRI - the plasticity retention index after accelerated aging) of rubber were determined using multivariate regression models. Two hundred and eighty six samples of rubber were measured using conventional and hyperspectral near-infrared imaging reflectance instruments in the range of 1000-2500 nm. The sample set was split into regression (n = 191) and external validation (n = 95) sub-sets. Three instruments were employed for data acquisition: a line scanning hyperspectral camera and two conventional FT-NIR spectrometers. Sample heterogeneity was evaluated using hyperspectral images obtained with a resolution of 150 × 150 μm and principal component analysis. The probed sample area (5 cm(2); 24,000 pixels) to achieve representativeness was found to be equivalent to the average of 6 spectra for a 1 cm diameter probing circular window of one FT-NIR instrument. The other spectrophotometer can probe the whole sample in only one measurement. The results show that the rubber properties can be determined with very similar accuracy and precision by Partial Least Square (PLS) regression models regardless of whether HI-NIR or conventional FT-NIR produce the spectral datasets. The best Root Mean Square Errors of Prediction (RMSEPs) of external validation for MV, PI0, PI30, and PRI were 4.3, 1.8, 3.4, and 5.3%, respectively. Though the quantitative results provided by the three instruments can be considered equivalent, the hyperspectral imaging instrument presents a number of advantages, being about 6 times faster than conventional bulk spectrometers, producing robust spectral data by ensuring sample

  1. Improved Debulking of Peritoneal Tumor Implants by Near-Infrared Fluorescent Nanobody Image Guidance in an Experimental Mouse Model.

    Science.gov (United States)

    Debie, Pieterjan; Vanhoeij, Marian; Poortmans, Natalie; Puttemans, Janik; Gillis, Kris; Devoogdt, Nick; Lahoutte, Tony; Hernot, Sophie

    2017-10-31

    Debulking followed by combination chemotherapy is currently regarded as the most effective treatment for advanced ovarian cancer. Prognosis depends drastically on the degree of debulking. Accordingly, near-infrared (NIR) fluorescence imaging has been proposed to revolutionize cancer surgery by acting as a sensitive, specific, and real-time tool enabling visualization of cancer lesions. We have previously developed a NIR-labeled nanobody that allows fast, specific, and high-contrast imaging of HER2-positive tumors. In this study, we applied this tracer during fluorescence-guided surgery in a mouse model and investigated the effect on surgical efficiency. 0.5 × 10 6 SKOV3.IP1-Luc+ cells were inoculated intraperitoneally in athymic mice and were allowed to grow for 30 days. Two nanomoles of IRDye800CW-anti-HER2 nanobody was injected intravenously. After 1h30, mice were killed, randomized in two groups, and subjected to surgery. In the first animal group (n = 7), lesions were removed by a conventional surgical protocol, followed by excision of remaining fluorescent tissue using a NIR camera. The second group of mice (n = 6) underwent directly fluorescence-guided surgery. Bioluminescence imaging was performed before and after surgery. Resected tissue was categorized as visualized during conventional surgery or not, fluorescent or not, and bioluminescent positive or negative. Fluorescence imaging allowed clear visualization of tumor nodules within the abdomen, up to submillimeter-sized lesions. Fluorescence guidance resulted in significantly reduced residual tumor as compared to conventional surgery. Moreover, sensitivity increased from 59.3 to 99.0 %, and the percentage of false positive lesions detected decreased from 19.6 to 7.1 %. This study demonstrates the advantage of intraoperative fluorescence imaging using nanobody-based tracers on the efficiency of debulking surgery.

  2. Development of a hardware-based registration system for the multimodal medical images by USB cameras

    International Nuclear Information System (INIS)

    Iwata, Michiaki; Minato, Kotaro; Watabe, Hiroshi; Koshino, Kazuhiro; Yamamoto, Akihide; Iida, Hidehiro

    2009-01-01

    There are several medical imaging scanners and each modality has different aspect for visualizing inside of human body. By combining these images, diagnostic accuracy could be improved, and therefore, several attempts for multimodal image registration have been implemented. One popular approach is to use hybrid image scanners such as positron emission tomography (PET)/CT and single photon emission computed tomography (SPECT)/CT. However, these hybrid scanners are expensive and not fully available. We developed multimodal image registration system with universal serial bus (USB) cameras, which is inexpensive and applicable to any combinations of existed conventional imaging scanners. The multiple USB cameras will determine the three dimensional positions of a patient while scanning. Using information of these positions and rigid body transformation, the acquired image is registered to the common coordinate which is shared with another scanner. For each scanner, reference marker is attached on gantry of the scanner. For observing the reference marker's position by the USB cameras, the location of the USB cameras can be arbitrary. In order to validate the system, we scanned a cardiac phantom with different positions by PET and MRI scanners. Using this system, images from PET and MRI were visually aligned, and good correlations between PET and MRI images were obtained after the registration. The results suggest this system can be inexpensively used for multimodal image registrations. (author)

  3. Evaluation of a cone beam computed tomography geometry for image guided small animal irradiation

    International Nuclear Information System (INIS)

    Yang, Yidong; Armour, Michael; Wang, Ken Kang-Hsin; Gandhi, Nishant; Wong, John; Iordachita, Iulian; Siewerdsen, Jeffrey

    2015-01-01

    The conventional imaging geometry for small animal cone beam computed tomography (CBCT) is that a detector panel rotates around the head-to-tail axis of an imaged animal (‘tubular’ geometry). Another unusual but possible imaging geometry is that the detector panel rotates around the anterior-to-posterior axis of the animal (‘pancake’ geometry). The small animal radiation research platform developed at Johns Hopkins University employs the pancake geometry where a prone-positioned animal is rotated horizontally between an x-ray source and detector panel. This study is to assess the CBCT image quality in the pancake geometry and investigate potential methods for improvement. We compared CBCT images acquired in the pancake geometry with those acquired in the tubular geometry when the phantom/animal was placed upright simulating the conventional CBCT geometry. Results showed signal-to-noise and contrast-to-noise ratios in the pancake geometry were reduced in comparison to the tubular geometry at the same dose level. But the overall spatial resolution within the transverse plane of the imaged cylinder/animal was better in the pancake geometry. A modest exposure increase to two folds in the pancake geometry can improve image quality to a level close to the tubular geometry. Image quality can also be improved by inclining the animal, which reduces streak artifacts caused by bony structures. The major factor resulting in the inferior image quality in the pancake geometry is the elevated beam attenuation along the long axis of the phantom/animal and consequently increased scatter-to-primary ratio in that orientation. Not withstanding, the image quality in the pancake-geometry CBCT is adequate to support image guided animal positioning, while providing unique advantages of non-coplanar and multiple mice irradiation. This study also provides useful knowledge about the image quality in the two very different imaging geometries, i.e. pancake and tubular geometry

  4. Evaluation of a cone beam computed tomography geometry for image guided small animal irradiation.

    Science.gov (United States)

    Yang, Yidong; Armour, Michael; Wang, Ken Kang-Hsin; Gandhi, Nishant; Iordachita, Iulian; Siewerdsen, Jeffrey; Wong, John

    2015-07-07

    The conventional imaging geometry for small animal cone beam computed tomography (CBCT) is that a detector panel rotates around the head-to-tail axis of an imaged animal ('tubular' geometry). Another unusual but possible imaging geometry is that the detector panel rotates around the anterior-to-posterior axis of the animal ('pancake' geometry). The small animal radiation research platform developed at Johns Hopkins University employs the pancake geometry where a prone-positioned animal is rotated horizontally between an x-ray source and detector panel. This study is to assess the CBCT image quality in the pancake geometry and investigate potential methods for improvement. We compared CBCT images acquired in the pancake geometry with those acquired in the tubular geometry when the phantom/animal was placed upright simulating the conventional CBCT geometry. Results showed signal-to-noise and contrast-to-noise ratios in the pancake geometry were reduced in comparison to the tubular geometry at the same dose level. But the overall spatial resolution within the transverse plane of the imaged cylinder/animal was better in the pancake geometry. A modest exposure increase to two folds in the pancake geometry can improve image quality to a level close to the tubular geometry. Image quality can also be improved by inclining the animal, which reduces streak artifacts caused by bony structures. The major factor resulting in the inferior image quality in the pancake geometry is the elevated beam attenuation along the long axis of the phantom/animal and consequently increased scatter-to-primary ratio in that orientation. Not withstanding, the image quality in the pancake-geometry CBCT is adequate to support image guided animal positioning, while providing unique advantages of non-coplanar and multiple mice irradiation. This study also provides useful knowledge about the image quality in the two very different imaging geometries, i.e. pancake and tubular geometry, respectively.

  5. Microscope-integrated optical coherence tomography for image-aided positioning of glaucoma surgery

    Science.gov (United States)

    Li, Xiqi; Wei, Ling; Dong, Xuechuan; Huang, Ping; Zhang, Chun; He, Yi; Shi, Guohua; Zhang, Yudong

    2015-07-01

    Most glaucoma surgeries involve creating new aqueous outflow pathways with the use of a small surgical instrument. This article reported a microscope-integrated, real-time, high-speed, swept-source optical coherence tomography system (SS-OCT) with a 1310-nm light source for glaucoma surgery. A special mechanism was designed to produce an adjustable system suitable for use in surgery. A two-graphic processing unit architecture was used to speed up the data processing and real-time volumetric rendering. The position of the surgical instrument can be monitored and measured using the microscope and a grid-inserted image of the SS-OCT. Finally, experiments were simulated to assess the effectiveness of this integrated system. Experimental results show that this system is a suitable positioning tool for glaucoma surgery.

  6. Microscope-integrated optical coherence tomography for image-aided positioning of glaucoma surgery.

    Science.gov (United States)

    Li, Xiqi; Wei, Ling; Dong, Xuechuan; Huang, Ping; Zhang, Chun; He, Yi; Shi, Guohua; Zhang, Yudong

    2015-07-01

    Most glaucoma surgeries involve creating new aqueous outflow pathways with the use of a small surgical instrument. This article reported a microscope-integrated, real-time, high-speed, swept-source optical coherence tomography system (SS-OCT) with a 1310-nm light source for glaucoma surgery. A special mechanism was designed to produce an adjustable system suitable for use in surgery. A two-graphic processing unit architecture was used to speed up the data processing and real-time volumetric rendering. The position of the surgical instrument can be monitored and measured using the microscope and a grid-inserted image of the SS-OCT. Finally, experiments were simulated to assess the effectiveness of this integrated system. Experimental results show that this system is a suitable positioning tool for glaucoma surgery.

  7. The use of a standardized positioning support cushion during daily routine of breast irradiation

    International Nuclear Information System (INIS)

    Thilmann, Christoph; Adamietz, Irenaeus A.; Saran, Frank; Mose, Stefan; Kostka, A.; Boettcher, H.D.

    1998-01-01

    Purpose: The use of positioning and immobilization techniques during external beam irradiation of the female breast is time consuming and expensive. The currently available standardized positioning devices are insufficient. For this reason, we designed a new and generally useable hard foam positioning support cushion for the use during breast irradiation, and tested its clinical usefulness in a prospective study. Methods and Materials: Fifty-five female breast cancer patients receiving adjuvant radiotherapy following breast-conservative surgery were irradiated either without immobilization (n = 27) or with the positioning support cushion (n = 28). The time necessary for patient setup, the lying subjective comfort and --comparing portal images with simulator images--the reproducibility of the set up were determined. Results: Irradiation reproducibility was significantly improved (average deviation without positioning support cushion: 8.4 mm, with positioning support cushion: 6.1 mm, p < 0.001). The time required for the positioning of the patient with positioning support cushion was in average 73 s, without cushion it was 55 s. A significantly higher proportion of patients (72%) found the position with the positioning support cushion as pleasant, whereas only 46% of patients were pleased with the position without cushion. Conclusion: The positioning support cushion designed in our department makes a substantial contribution to quality assurance in breast irradiation. It significantly increases the patients' comfort in a supine position. In contrast to conventional positioning and fixation aids it may be quickly and easily applied at low costs. Therefore, its use can be recommended

  8. Investigations on uncertainties in patient positioning for prostate treatment with EPID; Untersuchungen zur Positionierungsgenauigkeit bei Prostatakonformationsbestrahlungen mittels Portal-Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Bakai, A.; Nuesslin, F. [Universitaetsklinik fuer Radioonkologie, Tuebingen (Germany). Abt. Medizinische Physik; Paulsen, F.; Plasswilm, L.; Bamberg, M. [Universitaetsklinik fuer Radioonkologie, Tuebingen (Germany). Abt. Strahlentherapie

    2002-02-01

    Background: Conformal radiotherapy techniques as used in prostate treatment allow to spare normal tissue by conforming the radiation fields to the shape of the planning target volume (PTV). To be able to fully utilize the advantages of these techniques correct patient positioning is an important prerequisite. This study employing an electronic portal imaging device (EPID) investigated the positioning uncertainties that occur in the pelvic region for different patient positioning devices. Patients and Methods: 15 patients with prostate cancer were irradiated with or without rectal balloon/pelvic mask at a linear accelerator with multileaf collimator (MLC). For each patient multiple portal images were taken from different directions and compared to the digitally reconstructed radiographs (DRRs) of the treatment planning system and to simulation films (Table 1, Figure 1). Results: In spite of different positioning devices, all patients showed comparable total positioning uncertainties of 4.0 mm (lateral), 4.5 mm (cranio-caudal) and 1.7 mm (dorso-ventral). The lateral positioning error was reduced for the pelvic mask patients while the cranio-caudal error increased (Table 2, Figure 2). A systematic and a random component sum up to the total positioning error, and a good estimate of the magnitudes of the two is possible from six to eight portal images (Figure 3). Conclusions: With a small number of portal images it is possible to find out the systematic and random positioning error of a patient. Knowledge of the random error can be used to resize the treatment margin which is clinically relevant since this error differs greatly for different patients (Figure 4). Image analysis with EPID is convenient, yet has some problems. For example, one only gets indirect information on the movement of the ventral rectum wall. The successful operation of positioning devices, although, needs further improvement - especially if one focuses on IMRT. (orig.) [German] Hintergrund

  9. A randomized, double-blind, crossover comparison of novel continuous bed motion versus traditional bed position whole-body PET/CT imaging

    International Nuclear Information System (INIS)

    Schatka, Imke; Weiberg, Desiree; Reichelt, Stephanie; Owsianski-Hille, Nicole; Derlin, Thorsten; Berding, Georg; Bengel, Frank M.

    2016-01-01

    Continuous bed motion has recently been introduced for whole-body PET/CT, and represents a paradigm shift towards individualized and flexible acquisition without the limitations of bed position-based planning. Increased patient comfort due to lack of abrupt table position changes may be another albeit still unproven advantage. For robust clinical implementation, image quality and quantitative accuracy should at least be equal to the prior standard of bed position-based step-and-shoot imaging. The study included 68 consecutive patients referred for whole-body PET/CT for various malignancies. The patients underwent traditional step-and-shoot and novel continuous bed motion acquisition in the same session in a randomized crossover design. The patients and two independent observers were blinded to the sequence of scan techniques. Patient comfort/satisfaction was examined using a standardized questionnaire. SUVs were compared for reference tissue (liver, muscle) and tumour lesions. PET image quality and misalignment with CT images were evaluated on a scale of 1 - 4. Patients preferred continuous bed motion over step-and-shoot (P = 0.0001). It was considered to be more relaxing (38 % vs. 8 %), quieter (34 % vs. 8 %), and more fluid (64 % vs. 8 %). Image quality, SUV and CT misalignment did not differ between the techniques. Continuous bed motion resulted in better end-plane image quality (P < 0.0001). Regardless of the technique, second examinations had significantly higher tumour lesion SUVmax values (P = 0.0002), and a higher CT misalignment score (P = 0.0017). Oncological PET/CT with continuous bed motion enhances patient comfort and is associated with image quality at least comparable to that with traditional bed position-based step-and-shoot acquisition. (orig.)

  10. A randomized, double-blind, crossover comparison of novel continuous bed motion versus traditional bed position whole-body PET/CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Schatka, Imke [Hannover Medical School, Department of Nuclear Medicine, Hannover (Germany); Charite, Department of Nuclear Medicine, Berlin (Germany); Weiberg, Desiree; Reichelt, Stephanie; Owsianski-Hille, Nicole; Derlin, Thorsten; Berding, Georg; Bengel, Frank M. [Hannover Medical School, Department of Nuclear Medicine, Hannover (Germany)

    2016-04-15

    Continuous bed motion has recently been introduced for whole-body PET/CT, and represents a paradigm shift towards individualized and flexible acquisition without the limitations of bed position-based planning. Increased patient comfort due to lack of abrupt table position changes may be another albeit still unproven advantage. For robust clinical implementation, image quality and quantitative accuracy should at least be equal to the prior standard of bed position-based step-and-shoot imaging. The study included 68 consecutive patients referred for whole-body PET/CT for various malignancies. The patients underwent traditional step-and-shoot and novel continuous bed motion acquisition in the same session in a randomized crossover design. The patients and two independent observers were blinded to the sequence of scan techniques. Patient comfort/satisfaction was examined using a standardized questionnaire. SUVs were compared for reference tissue (liver, muscle) and tumour lesions. PET image quality and misalignment with CT images were evaluated on a scale of 1 - 4. Patients preferred continuous bed motion over step-and-shoot (P = 0.0001). It was considered to be more relaxing (38 % vs. 8 %), quieter (34 % vs. 8 %), and more fluid (64 % vs. 8 %). Image quality, SUV and CT misalignment did not differ between the techniques. Continuous bed motion resulted in better end-plane image quality (P < 0.0001). Regardless of the technique, second examinations had significantly higher tumour lesion SUVmax values (P = 0.0002), and a higher CT misalignment score (P = 0.0017). Oncological PET/CT with continuous bed motion enhances patient comfort and is associated with image quality at least comparable to that with traditional bed position-based step-and-shoot acquisition. (orig.)

  11. Imaging of the Achilles tendon in spondyloarthritis: a comparison of ultrasound and conventional, short and ultrashort echo time MRI with and without intravenous contrast

    International Nuclear Information System (INIS)

    Hodgson, R.J.; Emery, P.; Grainger, A.J.; O'Connor, P.J.; Evans, R.; Coates, L.; Marzo-Ortega, H.; Helliwell, P.; McGonagle, D.; Robson, M.D.

    2011-01-01

    To compare conventional MRI, ultrashort echo time MRI and ultrasound for assessing the extent of tendon abnormalities in spondyloarthritis. 25 patients with spondyloarthritis and Achilles symptoms were studied with MRI and ultrasound. MR images of the Achilles tendon were acquired using T1-weighted spin echo, gradient echo and ultrashort echo time (UTE) sequences with echo times (TE) between 0.07 and 16 ms, before and after intravenous contrast medium. Greyscale and power Doppler ultrasound were also performed. The craniocaudal extent of imaging abnormalities measured by a consultant musculoskeletal radiologist was compared between the different techniques. Abnormalities were most extensive on spoiled gradient echo images with TE=2 ms. Contrast enhancement after intravenous gadolinium was greatest on the UTE images (TE=0.07 ms). Fewer abnormalities were demonstrated using unenhanced UTE. Abnormalities were more extensive on MRI than ultrasound. Contrast enhancement was more extensive than power Doppler signal. 3D spoiled gradient echo images with an echo time of 2 ms demonstrate more extensive tendon abnormalities than the other techniques in spondyloarthritis. Abnormalities of vascularity are best demonstrated on enhanced ultrashort echo time images. (orig.)

  12. Continuous imaging space in three-dimensional integral imaging

    International Nuclear Information System (INIS)

    Zhang Lei; Yang Yong; Wang Jin-Gang; Zhao Xing; Fang Zhi-Liang; Yuan Xiao-Cong

    2013-01-01

    We report an integral imaging method with continuous imaging space. This method simultaneously reconstructs real and virtual images in the virtual mode, with a minimum gap that separates the entire imaging space into real and virtual space. Experimental results show that the gap is reduced to 45% of that in a conventional integral imaging system with the same parameters. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  13. Kinematic CT and MR imaging of the patellofemoral joint

    International Nuclear Information System (INIS)

    Muhle, C.; Brossmann, J.; Heller, M.

    1999-01-01

    Anterior knee pain is a frequently encountered orthopedic symptom and is often associated with patellofemoral malalignment, which may cause chondromalacia of the patella. The difficulty in determining the patellar position between 0 and 30 of knee flexion with a conventional axial radiographic examination is well known. The introduction of computed tomography (CT) and magnetic resonance (MR) imaging for the diagnosis of knee joint abnormalities has enabled assessment of the patellar position in this critical range. More recently, emphasis has been placed on dynamic visualization of patellar motion to detect an abnormal tracking pattern. The important influence of the quadriceps muscle on the patellar tracking pattern is well known and has been examined during active knee extension by the use of ultrafast CT, and motion-triggered and ultrafast MR imaging. This article provides an overview of the current status of kinematic CT and MR imaging in the diagnosis of patellofemoral alignment, its clinical implications, and future directions. (orig.)

  14. Kinematic CT and MR imaging of the patellofemoral joint

    Energy Technology Data Exchange (ETDEWEB)

    Muhle, C.; Brossmann, J.; Heller, M. [Klinik fuer Radiologische Diagnostik, Christian-Albrechts-Universitaet, Kiel (Germany)

    1999-04-01

    Anterior knee pain is a frequently encountered orthopedic symptom and is often associated with patellofemoral malalignment, which may cause chondromalacia of the patella. The difficulty in determining the patellar position between 0 and 30 of knee flexion with a conventional axial radiographic examination is well known. The introduction of computed tomography (CT) and magnetic resonance (MR) imaging for the diagnosis of knee joint abnormalities has enabled assessment of the patellar position in this critical range. More recently, emphasis has been placed on dynamic visualization of patellar motion to detect an abnormal tracking pattern. The important influence of the quadriceps muscle on the patellar tracking pattern is well known and has been examined during active knee extension by the use of ultrafast CT, and motion-triggered and ultrafast MR imaging. This article provides an overview of the current status of kinematic CT and MR imaging in the diagnosis of patellofemoral alignment, its clinical implications, and future directions. (orig.) With 13 figs., 5 tabs., 47 refs.

  15. Image reconstruction methods in positron tomography

    International Nuclear Information System (INIS)

    Townsend, D.W.; Defrise, M.

    1993-01-01

    In the two decades since the introduction of the X-ray scanner into radiology, medical imaging techniques have become widely established as essential tools in the diagnosis of disease. As a consequence of recent technological and mathematical advances, the non-invasive, three-dimensional imaging of internal organs such as the brain and the heart is now possible, not only for anatomical investigations using X-ray but also for studies which explore the functional status of the body using positron-emitting radioisotopes. This report reviews the historical and physical basis of medical imaging techniques using positron-emitting radioisotopes. Mathematical methods which enable three-dimensional distributions of radioisotopes to be reconstructed from projection data (sinograms) acquired by detectors suitably positioned around the patient are discussed. The extension of conventional two-dimensional tomographic reconstruction algorithms to fully three-dimensional reconstruction is described in detail. (orig.)

  16. Statistical processing of large image sequences.

    Science.gov (United States)

    Khellah, F; Fieguth, P; Murray, M J; Allen, M

    2005-01-01

    The dynamic estimation of large-scale stochastic image sequences, as frequently encountered in remote sensing, is important in a variety of scientific applications. However, the size of such images makes conventional dynamic estimation methods, for example, the Kalman and related filters, impractical. In this paper, we present an approach that emulates the Kalman filter, but with considerably reduced computational and storage requirements. Our approach is illustrated in the context of a 512 x 512 image sequence of ocean surface temperature. The static estimation step, the primary contribution here, uses a mixture of stationary models to accurately mimic the effect of a nonstationary prior, simplifying both computational complexity and modeling. Our approach provides an efficient, stable, positive-definite model which is consistent with the given correlation structure. Thus, the methods of this paper may find application in modeling and single-frame estimation.

  17. Strain-Encoded Cardiac Magnetic Resonance Imaging as an Adjunct for Dobutamine Stress Testing. Incremental Value to Conventional Wall Motion Analysis

    Science.gov (United States)

    Korosoglou, Grigorios; Lossnitzer, Dirk; Schellberg, Dieter; Lewien, Antje; Wochele, Angela; Schaeufele, Tim; Neizel, Mirja; Steen, Henning; Giannitsis, Evangelos; Katus, Hugo A.; Osman, Nael F.

    2009-01-01

    Background High-dose dobutamine stress magnetic resonance imaging (DS-MRI) is safe and feasible for the diagnosis of coronary artery disease (CAD) in humans. However, the assessment of cine scans relies on the visual interpretation of regional wall motion, which is subjective. Recently, Strain-Encoded MRI (SENC) has been proposed for the direct color-coded visualization of myocardial strain. The purpose of our study was to compare the diagnostic value of SENC to that provided by conventional wall motion analysis for the detection of inducible ischemia during DS-MRI. Methods and Results Stress induced ischemia was assessed by wall motion analysis and by SENC in 101 patients with suspected or known CAD and in 17 healthy volunteers who underwent DS-MRI in a clinical 1.5T scanner. Quantitative coronary angiography deemed as the standard reference for the presence or absence of significant CAD (≥50% diameter stenosis). On a coronary vessel level, SENC detected inducible ischemia in 86/101 versus 71/101 diseased coronary vessels (p<0.01 versus cine), and showed normal strain response in 189/202 versus 194/202 vessels with <50% stenosis (p=NS versus cine). On a patient level, SENC detected inducible ischemia in 63/64 versus 55/64 patients with CAD (p<0.05 versus cine), and showed normal strain response in 32/37 versus 34/37 patients without CAD (p=NS versus cine).Quantification analysis demonstrated a significant correlation between strain rate reserve (SRreserve) and coronary artery stenosis severity (r²=0.56, p<0.001), and a cut-off value of SRreserve=1.64 deemed as a highly accurate marker for the detection of stenosis≥50% (AUC=0.96, SE=0.01, 95% CI = 0.94–0.98, p<0.001). Conclusions The direct color-coded visualization of strain on MR-images is a useful adjunct for DS-MRI, which provides incremental value for the detection of CAD compared to conventional wall motion readings on cine images. PMID:19808579

  18. Automatic detection of patient identification and positioning errors in radiation therapy treatment using 3-dimensional setup images.

    Science.gov (United States)

    Jani, Shyam S; Low, Daniel A; Lamb, James M

    2015-01-01

    To develop an automated system that detects patient identification and positioning errors between 3-dimensional computed tomography (CT) and kilovoltage CT planning images. Planning kilovoltage CT images were collected for head and neck (H&N), pelvis, and spine treatments with corresponding 3-dimensional cone beam CT and megavoltage CT setup images from TrueBeam and TomoTherapy units, respectively. Patient identification errors were simulated by registering setup and planning images from different patients. For positioning errors, setup and planning images were misaligned by 1 to 5 cm in the 6 anatomical directions for H&N and pelvis patients. Spinal misalignments were simulated by misaligning to adjacent vertebral bodies. Image pairs were assessed using commonly used image similarity metrics as well as custom-designed metrics. Linear discriminant analysis classification models were trained and tested on the imaging datasets, and misclassification error (MCE), sensitivity, and specificity parameters were estimated using 10-fold cross-validation. For patient identification, our workflow produced MCE estimates of 0.66%, 1.67%, and 0% for H&N, pelvis, and spine TomoTherapy images, respectively. Sensitivity and specificity ranged from 97.5% to 100%. MCEs of 3.5%, 2.3%, and 2.1% were obtained for TrueBeam images of the above sites, respectively, with sensitivity and specificity estimates between 95.4% and 97.7%. MCEs for 1-cm H&N/pelvis misalignments were 1.3%/5.1% and 9.1%/8.6% for TomoTherapy and TrueBeam images, respectively. Two-centimeter MCE estimates were 0.4%/1.6% and 3.1/3.2%, respectively. MCEs for vertebral body misalignments were 4.8% and 3.6% for TomoTherapy and TrueBeam images, respectively. Patient identification and gross misalignment errors can be robustly and automatically detected using 3-dimensional setup images of different energies across 3 commonly treated anatomical sites. Copyright © 2015 American Society for Radiation Oncology. Published by

  19. Studying neonatal bilirubin encephalopathy with conventional MRI, MRS, and DWI

    International Nuclear Information System (INIS)

    Wang, Xiaoyi; Wu, Wulin; Chineah, Ashley; Liu, Fan; Liao, Weihua; Hou, Bob L.; Zhang, Ping

    2008-01-01

    The purpose of this study was to evaluate the diagnostic value of conventional magnetic resonance imaging (MRI), proton magnetic resonance spectroscopy ( 1 H-MRS), and diffusion-weighted imaging (DWI) for neonatal bilirubin encephalopathy. We collected conventional MRI in 24 neonates with neonatal bilirubin encephalopathy. We performed 1 H-MRS and DWI sequences to nine of the 24 patients and seven age-matched healthy control subjects. Multiple-voxel 1 H-MRS data were acquired using PRESS pulse sequence with TE=135 ms and TR=1500 ms. The spectroscopic regions of interest were the bilateral basal ganglia and thalamus with a 1.0 mL spatial resolution. The data from DWI were collected by using a single shot-spin echo-echo planar imaging sequence with TR/TE: 2900/98, and imaging regions were also focused on the bilateral basal ganglia and thalamus. Nineteen of the 24 patients had abnormal T 1 -weighted image hyperintensity in the globus pallidus, but these lesions appeared as normal T 2 -weighted image intensity in the same region. Ten of the 24 patients had T 1 -weighted image high signal intensity in the subthalamic nucleus and appeared as normal intensity in the region for the T 2 -weighted images. The peak area ratios of NAA/Cho and NAA/Cr were significantly decreased (t-test, P 1 H-MRS are important complementary tools in the diagnosis of neonatal bilirubin encephalopathy. The study provides important information for applying these MR modalities to evaluate neonates with bilirubin encephalopathy. (orig.)

  20. Gamma-ray detectors for breast imaging

    Science.gov (United States)

    Williams, Mark B.; Goode, Allen R.; Majewski, Stan; Steinbach, Daniela; Weisenberger, Andrew G.; Wojcik, Randolph F.; Farzanpay, Farzin

    1997-07-01

    Breast cancer is the most common cancer of American women and is the leading cause of cancer-related death among women aged 15 - 54; however recent years have shown that early detection using x-ray mammography can lead to a high probability of cure. However, because of mammography's low positive predictive value, surgical or core biopsy is typically required for diagnosis. In addition, the low radiographic contrast of many nonpalpable breast masses, particularly among women with radiographically dense breasts, results in an overall rate of 10% to 25% for missed tumors. Nuclear imaging of the breast using single gamma emitters (scintimammography) such as (superscript 99m)Tc, or positron emitters such as F-18- fluorodeoxyglucose (FDG) for positron emission tomography (PET), can provide information on functional or metabolic tumor activity that is complementary to the structural information of x-ray mammography, thereby potentially reducing the number of unnecessary biopsies and missed cancers. This paper summarizes recent data on the efficacy of scintimammography using conventional gamma cameras, and describes the development of dedicated detectors for gamma emission breast imaging. The detectors use new, high density crystal scintillators and large area position sensitive photomultiplier tubes (PSPMTs). Detector design, imaging requirements, and preliminary measured imaging performance are discussed.

  1. Effect of intervertebral disk degeneration on spinal stenosis during magnetic resonance imaging with axial loading

    International Nuclear Information System (INIS)

    Ahn, Tae-Joon; Lee, Sang-Ho; Choi, Gun; Ahn, Yong; Liu, Wei-Chiang; Kim, Ho-Jin; Lee, Ho-Yeon

    2009-01-01

    Magnetic resonance (MR) imaging with axial loading can simulate the physiological standing state and disclose spinal stenosis undetected or underestimated in the conventional position. Intervertebral disk degeneration may be an important factor in spinal stenosis. This study investigated whether intervertebral disk degeneration increases spinal stenosis during axial loading. MR imaging with and without axial loading was obtained in 51 patients with neurogenic intermittent claudication and/or sciatica and reviewed retrospectively. The grade of disk degeneration was rated in four disk spaces from L2-3 to L5-S1. The dural sac cross-sectional area (DCSA) was measured on MR images taken in both conventional and axial loading positions, and the change in the DCSA was calculated. The effect of disk degeneration on the DCSA was statistically analyzed. Significant decreases in the DCSA occurred with grade 4 disk degeneration (mean±standard deviation, 20.1±14.1 mm 2 ), followed by grade 3 (18.3±15.1 mm 2 ) and grade 2 (8.9±13.1 mm 2 ). DCSA decreased considerably with increased severity of disk degeneration with axial loading, except for grade 5 disk degeneration. More accurate diagnosis of stenosis can be achieved using MR imaging with axial loading, especially if grade 2 to 4 disk degeneration is present. (author)

  2. Determinants of Liquidity Risk in Indonesian Islamic and Conventional Banks

    Directory of Open Access Journals (Sweden)

    Raditya Sukmana

    2016-07-01

    Full Text Available The purpose of the study is to examine the causes of the liquidity risk  in Islamic and conventional banks in Indonesia using panel data regression method. The study found the significant and positive relation of ROA and NPF with the liquidity risk, whereas the negative and significant relation of CAR with the liquidity risk in Indonesian Conventional Banks. Meanwhile in Islamic banks, CAR result significantly positive effect on liquidity risk, while ROA shows negative and significant result. Possible explanation for this is that, given the huge profit by the conventional banks, it has more chance to allocate it as liquidity reserve as well as increasing the facilities (improvement on technology. When the NPL is high, conventional banks will increase the liquid assets as a buffer. Unlike that of conventional banks, the Islamic banks in Indonesia might allocate capital as liquidity reserves and might allocate ROA in fixed assets or financing or technology. The result confirm that the role of capital and bank’s performance in indeed important to the banking liquidityDOI: 10.15408/aiq.v8i2.2871

  3. Drift correction for single-molecule imaging by molecular constraint field, a distance minimum metric

    International Nuclear Information System (INIS)

    Han, Renmin; Wang, Liansan; Xu, Fan; Zhang, Yongdeng; Zhang, Mingshu; Liu, Zhiyong; Ren, Fei; Zhang, Fa

    2015-01-01

    The recent developments of far-field optical microscopy (single molecule imaging techniques) have overcome the diffraction barrier of light and improve image resolution by a factor of ten compared with conventional light microscopy. These techniques utilize the stochastic switching of probe molecules to overcome the diffraction limit and determine the precise localizations of molecules, which often requires a long image acquisition time. However, long acquisition times increase the risk of sample drift. In the case of high resolution microscopy, sample drift would decrease the image resolution. In this paper, we propose a novel metric based on the distance between molecules to solve the drift correction. The proposed metric directly uses the position information of molecules to estimate the frame drift. We also designed an algorithm to implement the metric for the general application of drift correction. There are two advantages of our method: First, because our method does not require space binning of positions of molecules but directly operates on the positions, it is more natural for single molecule imaging techniques. Second, our method can estimate drift with a small number of positions in each temporal bin, which may extend its potential application. The effectiveness of our method has been demonstrated by both simulated data and experiments on single molecular images

  4. Comparative analysis of maximum renal longitudinal length with positional changes on ultrasound with multiplanar reconstructed MR image in Korea Adults

    International Nuclear Information System (INIS)

    Jang, Yun Hee; Cho, Bum Sang; Kang, Min Ho; Kang, Woo Young; Lee, Jisun; Kim, Yook; Lee, Soo Hyun; Lee, Soo Jung; Lee, Jin Yong

    2016-01-01

    The purpose of this study was to determine a suitable position in which the measured length on ultrasound is close to the true renal length obtained through a multiplanar reconstructed MR image. A total of 33 individuals (males: 15, females: 18) without any underlying renal disease were included in the present study. Renal length was measured as the longest axis at the level of the renal hilum in three positions-supine, lateral decubitus, and prone, respectively. With a 3.0 T MR scanner, 3D eTHRIVE was acquired. Subsequently, the maximum longitudinal length of both the kidneys was measured through multiplanar reconstructed MR images. Paired t-test was used to compare the renal length obtained from ultrasonographic measurement with the length obtained through multiplanar reconstructed MR images. Our study demonstrated significant difference between sonographic renal length in three positions and renal length through MRI (p < 0.001). However, the longest longitudinal length of right kidney among the measured three values by ultrasound was statistically similar to the renal length measured by reconstructed MR image. Among them, the lateral decubitus position showed the strongest correlation with true renal length (right: 0.887; left: 0.849). We recommend measurement of the maximum renal longitudinal length in all possible positions on ultrasonography. If not allowed, the best measurement is on the lateral decubitus showing the strongest correlation coefficient with true renal length

  5. Comparative analysis of maximum renal longitudinal length with positional changes on ultrasound with multiplanar reconstructed MR image in Korea Adults

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Yun Hee; Cho, Bum Sang; Kang, Min Ho; Kang, Woo Young; Lee, Jisun; Kim, Yook; Lee, Soo Hyun; Lee, Soo Jung [Dept. of Radiology, Chungbuk National University Hospital, Cheongju (Korea, Republic of); Lee, Jin Yong [Public Health Medical Service, Seoul National University Boramae Medical Center, Seoul (Korea, Republic of)

    2016-07-15

    The purpose of this study was to determine a suitable position in which the measured length on ultrasound is close to the true renal length obtained through a multiplanar reconstructed MR image. A total of 33 individuals (males: 15, females: 18) without any underlying renal disease were included in the present study. Renal length was measured as the longest axis at the level of the renal hilum in three positions-supine, lateral decubitus, and prone, respectively. With a 3.0 T MR scanner, 3D eTHRIVE was acquired. Subsequently, the maximum longitudinal length of both the kidneys was measured through multiplanar reconstructed MR images. Paired t-test was used to compare the renal length obtained from ultrasonographic measurement with the length obtained through multiplanar reconstructed MR images. Our study demonstrated significant difference between sonographic renal length in three positions and renal length through MRI (p < 0.001). However, the longest longitudinal length of right kidney among the measured three values by ultrasound was statistically similar to the renal length measured by reconstructed MR image. Among them, the lateral decubitus position showed the strongest correlation with true renal length (right: 0.887; left: 0.849). We recommend measurement of the maximum renal longitudinal length in all possible positions on ultrasonography. If not allowed, the best measurement is on the lateral decubitus showing the strongest correlation coefficient with true renal length.

  6. Visible imaging measurement of position and displacement of the last closed flux surface in EAST tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Y.F. [School of Nuclear Science and Technology, University of Science and Technology of China, Hefei 230026 (China); Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Xu, G.S., E-mail: gsxu@ipp.ac.cn [School of Nuclear Science and Technology, University of Science and Technology of China, Hefei 230026 (China); Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Li, Y.L.; Yang, J.H.; Yan, N.; Liu, L.; Yuan, S.; Luo, Z.P. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Sang, C.F. [School of Physics and Optoelectronic Technology, Dalian University of Technology, Dalian 116024 (China); Gu, S.; Xu, J.C.; Hu, G.H.; Wang, Y.S. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Peng, Y.K.M.; Wan, B.N. [School of Nuclear Science and Technology, University of Science and Technology of China, Hefei 230026 (China); Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China)

    2017-06-15

    Highlights: • A new method for measuring the position and displacement of the LCFS has been developed in EAST tokamak. • This method is based on the visible imaging diagnostic and shown to be an effective and convenient approach. • This method can be applied to measure displacements of the LCFS during application of resonant magnetic perturbation fields. - Abstract: A new method for measuring the position and displacement of the last closed flux surface (LCFS) with visible imaging diagnostics has been developed in EAST. By measuring the relative intensity profiles of the green visible Li-II emission in the tangential planes of the optical systems, it is possible to infer the positions of certain points on the LCFS. This emission line is readily available in discharges with Li-coating wall routinely employed to improve the plasma performance. We describe the measuring method, giving results which are compared with those obtained by EFIT, and showing this as an effective and convenient approach to determine the position of the LCFS. This method is further applied to measure the displacements of the LCFS during application of resonant magnetic perturbation fields in the EAST tokamak.

  7. Energy dispersive detector for white beam synchrotron x-ray fluorescence imaging

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Matthew D., E-mail: Matt.Wilson@stfc.ac.uk; Seller, Paul; Veale, Matthew C. [Science and Technology Facilities Council, Rutherford Appleton Laboratory, Harwell Campus,UK (United Kingdom); Connolley, Thomas [Diamond Light Source, I12 Beamline, Harwell Campus, Didcot, Oxfordshire (United Kingdom); Dolbnya, Igor P.; Malandain, Andrew; Sawhney, Kawal [Diamond Light Source, B16 Beamline, Harwell Campus, Didcot, Oxfordshire (United Kingdom); Grant, Patrick S.; Liotti, Enzo; Lui, Andrew [Department of Materials, University of Oxford Parks Road, Oxford (United Kingdom)

    2016-07-27

    A novel, “single-shot” fluorescence imaging technique has been demonstrated on the B16 beamline at the Diamond Light Source synchrotron using the HEXITEC energy dispersive imaging detector. A custom made furnace with 200µm thick metal alloy samples was positioned in a white X-ray beam with a hole made in the furnace walls to allow the transmitted beam to be imaged with a conventional X-ray imaging camera consisting of a 500 µm thick single crystal LYSO scintillator, mirror and lens coupled to an AVT Manta G125B CCD sensor. The samples were positioned 45° to the incident beam to enable simultaneous transmission and fluorescence imaging. The HEXITEC detector was positioned at 90° to the sample with a 50 µm pinhole 13 cm from the sample and the detector positioned 2.3m from pinhole. The geometric magnification provided a field of view of 1.1×1.1mm{sup 2} with one of the 80×80 pixels imaging an area equivalent to 13µm{sup 2}. Al-Cu alloys doped with Zr, Ag and Mo were imaged in transmission and fluorescence mode. The fluorescence images showed that the dopant metals could be simultaneously imaged with sufficient counts on all 80x80 pixels within 60 s, with the X-ray flux limiting the fluorescence imaging rate. This technique demonstrated that it is possible to simultaneously image and identify multiple elements on a spatial resolution scale ~10µm or higher without the time consuming need to scan monochromatic energies or raster scan a focused beam of X-rays. Moving to high flux beamlines and using an array of detectors could improve the imaging speed of the technique with element specific imaging estimated to be on a 1 s timescale.

  8. Energy dispersive detector for white beam synchrotron x-ray fluorescence imaging

    International Nuclear Information System (INIS)

    Wilson, Matthew D.; Seller, Paul; Veale, Matthew C.; Connolley, Thomas; Dolbnya, Igor P.; Malandain, Andrew; Sawhney, Kawal; Grant, Patrick S.; Liotti, Enzo; Lui, Andrew

    2016-01-01

    A novel, “single-shot” fluorescence imaging technique has been demonstrated on the B16 beamline at the Diamond Light Source synchrotron using the HEXITEC energy dispersive imaging detector. A custom made furnace with 200µm thick metal alloy samples was positioned in a white X-ray beam with a hole made in the furnace walls to allow the transmitted beam to be imaged with a conventional X-ray imaging camera consisting of a 500 µm thick single crystal LYSO scintillator, mirror and lens coupled to an AVT Manta G125B CCD sensor. The samples were positioned 45° to the incident beam to enable simultaneous transmission and fluorescence imaging. The HEXITEC detector was positioned at 90° to the sample with a 50 µm pinhole 13 cm from the sample and the detector positioned 2.3m from pinhole. The geometric magnification provided a field of view of 1.1×1.1mm"2 with one of the 80×80 pixels imaging an area equivalent to 13µm"2. Al-Cu alloys doped with Zr, Ag and Mo were imaged in transmission and fluorescence mode. The fluorescence images showed that the dopant metals could be simultaneously imaged with sufficient counts on all 80x80 pixels within 60 s, with the X-ray flux limiting the fluorescence imaging rate. This technique demonstrated that it is possible to simultaneously image and identify multiple elements on a spatial resolution scale ~10µm or higher without the time consuming need to scan monochromatic energies or raster scan a focused beam of X-rays. Moving to high flux beamlines and using an array of detectors could improve the imaging speed of the technique with element specific imaging estimated to be on a 1 s timescale.

  9. HMB-45 reactivity in conventional uterine leiomyosarcomas.

    Science.gov (United States)

    Simpson, Karen W; Albores-Saavedra, Jorge

    2007-01-01

    We studied the human melanoma black-45 (HMB-45) reactivity in 25 uterine leiomyosarcomas including 23 conventional and 2 myxoid variants. Eleven tumors were poorly differentiated, and 14 were well to moderately differentiated. Nine uterine leiomyosarcomas labeled with HMB-45 in 10% or less of the tumor cells. Six were poorly differentiated and 3 were well differentiated. Our study indicates that 36% of conventional leiomyosarcomas focally express HMB-45. HMB-45 reactivity was more common in the poorly differentiated than in the well-differentiated group of leiomyosarcomas. In light of our findings and of those recently reported in the literature, we believe that the term PEComa should not be used for uterine leiomyosarcomas with clear cells or for conventional leiomyosarcomas that stain positively with HMB-45.

  10. Early small-bowel ischemia: dual-energy CT improves conspicuity compared with conventional CT in a swine model.

    Science.gov (United States)

    Potretzke, Theodora A; Brace, Christopher L; Lubner, Meghan G; Sampson, Lisa A; Willey, Bridgett J; Lee, Fred T

    2015-04-01

    To compare dual-energy computed tomography (CT) with conventional CT for the detection of small-bowel ischemia in an experimental animal model. The study was approved by the animal care and use committee and was performed in accordance with the Guide for Care and Use of Laboratory Animals issued by the National Research Council. Ischemic bowel segments (n = 8) were created in swine (n = 4) by means of surgical occlusion of distal mesenteric arteries and veins. Contrast material-enhanced dual-energy CT and conventional single-energy CT (120 kVp) sequences were performed during the portal venous phase with a single-source fast-switching dual-energy CT scanner. Attenuation values and contrast-to-noise ratios of ischemic and perfused segments on iodine material-density, monospectral dual-energy CT (51 keV, 65 keV, and 70 keV), and conventional 120-kVp CT images were compared. Linear mixed-effects models were used for comparisons. The attenuation difference between ischemic and perfused segments was significantly greater on dual-energy 51-keV CT images than on conventional 120-kVp CT images (mean difference, 91.7 HU vs 47.6 HU; P conventional CT by increasing attenuation differences between ischemic and perfused segments on low-kiloelectron volt and iodine material density images. © RSNA, 2014.

  11. 49th Annual Convention of the Computer Society of India CSI

    CERN Document Server

    Govardhan, A; Raju, K; Mandal, J

    2015-01-01

    Volume 1 contains 73 papers presented at CSI 2014: Emerging ICT for Bridging the Future: Proceedings of the 49th Annual Convention of Computer Society of India. The convention was held during 12-14, December, 2014 at Hyderabad, Telangana, India. This volume contains papers mainly focused on Fuzzy Systems, Image Processing, Software Engineering, Cyber Security and Digital Forensic, E-Commerce, Big Data, Cloud Computing and ICT applications.

  12. Positive body image: inter-ethnic and rural-urban differences among an indigenous sample from Malaysian Borneo.

    Science.gov (United States)

    Swami, Viren; Kannan, Kumaraswami; Furnham, Adrian

    2012-11-01

    Previous studies examining body image from a cross-cultural perspective have tended to neglect samples from different ethnic groups or along a rural-urban continuum. To overcome this limitation, the present study examined positive body image among rural and urban women from three major indigenous ethnic groups in Sabah, Malaysia. A total of 202 women completed the Body Appreciation Scale, as well as measures of media exposure and financial security, and provided their demographic details. s showed that there were significant rural-urban differences in body appreciation, with rural participants having significantly higher body appreciation than urban participants. A comparison with a previous data set of West Malaysian women (Swami & Chamorro-Premuzic, 2008) showed that the current urban sample had significantly lower body appreciation and that the rural group had significantly higher body appreciation. Further results showed that research site (urban vs rural) explained 11.0% of the variance in body appreciation. Participant body mass index and exposure to western forms of media explained an additional 2.0% of the variance. These results suggest that there are differences in body image between rural and urban women. Results are discussed in relation to the promotion of positive body image, particularly in developing societies where health care resources may be limited.

  13. Imaging of the hip joint. Computed tomography versus magnetic resonance imaging

    Science.gov (United States)

    Lang, P.; Genant, H. K.; Jergesen, H. E.; Murray, W. R.

    1992-01-01

    The authors reviewed the applications and limitations of computed tomography (CT) and magnetic resonance (MR) imaging in the assessment of the most common hip disorders. Magnetic resonance imaging is the most sensitive technique in detecting osteonecrosis of the femoral head. Magnetic resonance reflects the histologic changes associated with osteonecrosis very well, which may ultimately help to improve staging. Computed tomography can more accurately identify subchondral fractures than MR imaging and thus remains important for staging. In congenital dysplasia of the hip, the position of the nonossified femoral head in children less than six months of age can only be inferred by indirect signs on CT. Magnetic resonance imaging demonstrates the cartilaginous femoral head directly without ionizing radiation. Computed tomography remains the imaging modality of choice for evaluating fractures of the hip joint. In some patients, MR imaging demonstrates the fracture even when it is not apparent on radiography. In neoplasm, CT provides better assessment of calcification, ossification, and periosteal reaction than MR imaging. Magnetic resonance imaging, however, represents the most accurate imaging modality for evaluating intramedullary and soft-tissue extent of the tumor and identifying involvement of neurovascular bundles. Magnetic resonance imaging can also be used to monitor response to chemotherapy. In osteoarthrosis and rheumatoid arthritis of the hip, both CT and MR provide more detailed assessment of the severity of disease than conventional radiography because of their tomographic nature. Magnetic resonance imaging is unique in evaluating cartilage degeneration and loss, and in demonstrating soft-tissue alterations such as inflammatory synovial proliferation.

  14. Comparison of computed tomography, magnetic resonance imaging and conventional X-ray of the equine digit

    International Nuclear Information System (INIS)

    Kleiter, M.

    1996-10-01

    An anatomical study of the equine digit with computed tomography and magnetic resonance imaging was performed. In addition, the observed pathologic findings were compared with their diagnosticity in associated radiographs. Twenty isolated forelimbs were radiographed and compared with the according CT-images. From 19 isolated forelimbs and one hindlimb MR-images were taken using spinecho and overview gradient-echo sequences. The appearance of bone and soft tissue is described in various sectional positions. CT images allow excellent evaluation of bone tissue in cases in which the X-ray examination suffers from the superimposition of adjacent structures. Thus, in several cases of navicular disease additional findings were made using CT. An insertional desmopathy of the interosseus, a cartilagineous fetlock chip, a separation of the hoof wall and osteophytes of the distal phalanx were found with CT but not in the associated radiographs. MRI allows the specific diagnosis of joint-, ligament- and tendon diseases also in the hoof region. The possibility to evaluate the navicular region, the distal interphalangeal joint and the hoof matrix is of great diagnostic value. In one case of navicular d sease a defect of the flexor cortex with pannus formation could be diagnosed. In a case with chronical laminitis the separation of the epidermal lamellae and the growth of the scar horn were depicted. A tendinitis of the interosseus, fibrocartilage in the insertion of the deep digital flexor tendon, the interosseus and in the distal sesamoid ligaments are well documented. It is concluded that in some equine patients CT and MRI are indicated due to the substantial diagnostic information. (author)

  15. Multi-Institutional Evaluation of Digital Tomosynthesis, Dual-Energy Radiography, and Conventional Chest Radiography for the Detection and Management of Pulmonary Nodules.

    Science.gov (United States)

    Dobbins, James T; McAdams, H Page; Sabol, John M; Chakraborty, Dev P; Kazerooni, Ella A; Reddy, Gautham P; Vikgren, Jenny; Båth, Magnus

    2017-01-01

    Purpose To conduct a multi-institutional, multireader study to compare the performance of digital tomosynthesis, dual-energy (DE) imaging, and conventional chest radiography for pulmonary nodule detection and management. Materials and Methods In this binational, institutional review board-approved, HIPAA-compliant prospective study, 158 subjects (43 subjects with normal findings) were enrolled at four institutions. Informed consent was obtained prior to enrollment. Subjects underwent chest computed tomography (CT) and imaging with conventional chest radiography (posteroanterior and lateral), DE imaging, and tomosynthesis with a flat-panel imaging device. Three experienced thoracic radiologists identified true locations of nodules (n = 516, 3-20-mm diameters) with CT and recommended case management by using Fleischner Society guidelines. Five other radiologists marked nodules and indicated case management by using images from conventional chest radiography, conventional chest radiography plus DE imaging, tomosynthesis, and tomosynthesis plus DE imaging. Sensitivity, specificity, and overall accuracy were measured by using the free-response receiver operating characteristic method and the receiver operating characteristic method for nodule detection and case management, respectively. Results were further analyzed according to nodule diameter categories (3-4 mm, >4 mm to 6 mm, >6 mm to 8 mm, and >8 mm to 20 mm). Results Maximum lesion localization fraction was higher for tomosynthesis than for conventional chest radiography in all nodule size categories (3.55-fold for all nodules, P chest radiography for all nodules (1.49-fold, P chest radiography, as given by the area under the receiver operating characteristic curve (1.23-fold, P chest radiography or tomosynthesis. Conclusion Tomosynthesis outperformed conventional chest radiography for lung nodule detection and determination of case management; DE imaging did not show significant differences over conventional chest

  16. Stereographic Targeting in Prostate Radiotherapy: Speed and Precision by Daily Automatic Positioning Corrections Using Kilovoltage/Megavoltage Image Pairs

    International Nuclear Information System (INIS)

    Mutanga, Theodore F.; Boer, Hans C.J. de; Wielen, Gerard J. van der; Wentzler, Davy; Barnhoorn, Jaco; Incrocci, Luca; Heijmen, Ben J.M.

    2008-01-01

    Purpose: A fully automated, fast, on-line prostate repositioning scheme using implanted markers, kilovoltage/megavoltage imaging, and remote couch movements has been developed and clinically applied. The initial clinical results of this stereographic targeting (SGT) method, as well as phantom evaluations, are presented. Methods and Materials: Using the SGT method, portal megavoltage images are acquired with the first two to six monitor units of a treatment beam, immediately followed by acquisition of an orthogonal kilovoltage image without gantry motion. The image pair is automatically analyzed to obtain the marker positions and three-dimensional prostate displacement and rotation. Remote control couch shifts are applied to correct for the displacement. The SGT performance was measured using both phantom images and images from 10 prostate cancer patients treated using SGT. Results: With phantom measurements, the accuracy of SGT was 0.5, 0.2, and 0.3 mm (standard deviation [SD]) for the left-right, craniocaudal, and anteroposterior directions, respectively, for translations and 0.5 o (SD) for the rotations around all axes. Clinically, the success rate for automatic marker detection was 99.5%, and the accuracy was 0.3, 0.5 and 0.8 mm (SD) in the left-right, craniocaudal, and anteroposterior axes. The SDs of the systematic center-of-mass positioning errors (Σ) were reduced from 4.0 mm to <0.5 mm for all axes. The corresponding SD of the random (σ) errors was reduced from 3.0 to <0.8 mm. These small residual errors were achieved with a treatment time extension of <1 min. Conclusion: Stereographic targeting yields systematic and random prostate positioning errors of <1 mm with <1 min of added treatment time

  17. Central nervous system imaging

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    Since its introduction in 1973, computed tomography (CT) of the brain has had a revolutionary impact on neuroradiologic diagnosis. It has largely replaced radionuclide brain imaging as the initial, noninvasive neurologic screening examination. Although conventional radionuclide brain imaging still contributes useful and unique diagnostic information in a few clinical situations, it appears that new technology and applications must be found if nuclear imaging is to play a prominent future role in neurologic diagnosis as it did in the past. One of the main advantages of CT over radionuclide brain imaging at present is CT's ability to demonstrate the size, shape, and position of the cerebral ventricles and subarachnoid spaces. Another important strength of CT is the ability to differentiate ischemic cerebral infarction from intracerebral hemorrhage. The overall sensitivity of CT in detecting intracranial neoplasms is also greater than that of radionuclide brain imaging, and CT is very useful in demonstrating the effects of head trauma. Magnetic resonance imaging appears superior to CT in the evaluation of neurologic disorders. A renewed interest in radionuclide brain imaging has developed because of recent advances in emission computed tomographic imaging. When tracer kinetic models are used, cerebral blood flow (CBF), blood volume, metabolic rate, and glucose and amino acid transport can be measured. Other applications involve investigation of receptor bindings, evaluation of the blood-brain barrier, brain blood-volume measurement, and cisternography

  18. The value of imaging in standing position in preoperative breast lymphoscintigraphy.

    Science.gov (United States)

    Anagnostou, Christos; Baiocco, Cinzia; Arnulfo, Alberto; Liberatore, Mauro; Baccheschi, Anna Maria; Inglese, Eugenio

    2011-08-01

    Breast lymphoscintigraphy is an accurate technique, but in a minority of cases the sentinel node (SN) visualization cannot be achieved or can be very difficult. We evaluated the potential clinical advantages and limitations of performing imaging in the standing position. The aim was to establish if this examination modality is quicker and helpful in the presence of "hidden" SN, checking also for any influence of SN skin landmarking in the upright position on the correct intraoperative SN identification. The overall objective was to verify if the standing position can be routinely used in breast lymphoscintigraphy. A total of 144 patients underwent lymphoscintigraphy in both standing and supine positions. In both modalities, a skin landmark was set coincident with the SN orthogonal projections. The acquisition times of 2 groups (each consisting of 45 patients) examined with the standing or supine acquisition modality, were compared. In 6 cases with hidden SN and in 34 cases with difficult or partial visualization in one of the supine views, the standing protocol was effective and led to better and quicker visualization of lymph nodes (median examination time: 25.5 minutes standing, 35.5 minutes supine). Significant differences in skin landmark position between the 2 modalities were present only in overweight patients and in large breasts. This, however, did not have a negative impact on successful intraoperative localization of SN with the gamma probe. Standing acquisition resulted to be a faster, easier, and more accurate examination protocol and can be used as the routine method for SN detection in breast lymphoscintigraphy.

  19. Identifying Conventionally Sub-Seismic Faults in Polygonal Fault Systems

    Science.gov (United States)

    Fry, C.; Dix, J.

    2017-12-01

    Polygonal Fault Systems (PFS) are prevalent in hydrocarbon basins globally and represent potential fluid pathways. However the characterization of these pathways is subject to the limitations of conventional 3D seismic imaging; only capable of resolving features on a decametre scale horizontally and metres scale vertically. While outcrop and core examples can identify smaller features, they are limited by the extent of the exposures. The disparity between these scales can allow for smaller faults to be lost in a resolution gap which could mean potential pathways are left unseen. Here the focus is upon PFS from within the London Clay, a common bedrock that is tunnelled into and bears construction foundations for much of London. It is a continuation of the Ieper Clay where PFS were first identified and is found to approach the seafloor within the Outer Thames Estuary. This allows for the direct analysis of PFS surface expressions, via the use of high resolution 1m bathymetric imaging in combination with high resolution seismic imaging. Through use of these datasets surface expressions of over 1500 faults within the London Clay have been identified, with the smallest fault measuring 12m and the largest at 612m in length. The displacements over these faults established from both bathymetric and seismic imaging ranges from 30cm to a couple of metres, scales that would typically be sub-seismic for conventional basin seismic imaging. The orientations and dimensions of the faults within this network have been directly compared to 3D seismic data of the Ieper Clay from the offshore Dutch sector where it exists approximately 1km below the seafloor. These have typical PFS attributes with lengths of hundreds of metres to kilometres and throws of tens of metres, a magnitude larger than those identified in the Outer Thames Estuary. The similar orientations and polygonal patterns within both locations indicates that the smaller faults exist within typical PFS structure but are

  20. 2D position sensitive microstrip sensors with charge division along the strip Studies on the position measurement error

    CERN Document Server

    Bassignana, D; Fernandez, M; Jaramillo, R; Lozano, M; Munoz, F.J; Pellegrini, G; Quirion, D; Vila, I; Vitorero, F

    2013-01-01

    Position sensitivity in semiconductor detectors of ionizing radiation is usually achieved by the segmentation of the sensing diode junction in many small sensing elements read out separately as in the case of conventional microstrips and pixel detectors. Alternatively, position sensitivity can be obtained by splitting the ionization signal collected by one single electrode amongst more than one readout channel with the ratio of the collected charges depending on the position where the signal was primary generated. Following this later approach, we implemented the charge division method in a conventional microstrip detector to obtain position sensitivity along the strip. We manufactured a proofof-concept demonstrator where the conventional aluminum electrodes were replaced by slightly resistive electrodes made of strongly doped poly-crystalline silicon and being readout at both strip ends. Here, we partially summarize the laser characterization of this first proof-of-concept demonstrator with special emphasis ...