WorldWideScience

Sample records for controlled indoor environment

  1. Individually Controlled Indoor Environment

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor

    2004-01-01

    The thermal environment and inhaled air quality in buildings to which occupants are exposed has an effect on their health, comfort, performance and productivity. Heating, ventilating and air-conditioning (HVAC) of buildings today is designed to provide a uniform environment. However, large...... individual differences in physiological and psychological response, clothing insulation, activity, preference for air temperature and movement, etc., exist between people. Environmental conditions acceptable for most of the occupants in buildings may be achieved by providing each occupant...

  2. CONTROL OF INDOOR ENVIRONMENTS VIA THE REGULATION OF BUILDING ENVELOPES

    Directory of Open Access Journals (Sweden)

    Mitja Košir

    2011-01-01

    Full Text Available The design of comfortable, healthy and stimulating indoor environments in buildings has a direct impact on the users and on energy consumption, as well as on the wider soci-economic environment of society.The indoor environment of buildings is defined with the formulation of the building envelope, which functions as an interface between the internal and external environments and its users. A properly designed, flexible and adequately controlled building envelope is a starting point in the formulation of a high-quality indoor environment. The systematic treatment of the indoor environment and building envelope from a user’s point of view represents an engineering approach that enables the holistic treatment of buildings, as well as integrated components and systems. The presented division of indoor environment in terms of visual, thermal, olfactory, acoustic and ergonomic sub-environments enables the classification and selection of crucial factors influencing design. This selection and classification can be implemented in the design, as well as in control applications of the building envelope. The implementation of the approach described is demonstrated with an example of an automated control system for the internal environment of an office in the building of the Faculty of Civil and Geodetic Engineering.

  3. Occupant Behaviour with regard to Control of the Indoor Environment

    DEFF Research Database (Denmark)

    Andersen, Rune Vinther

    A large proportion of the world’s energy consumption is spent in an effort to maintain a comfortable and healthy indoor environment. As a consequence reductions in the energy consumed to climatise buildings are instrumental to the efforts of reducing energy related CO2 emissions and alleviating....... As a consequence, most programs are capable of accurate simulations of the physical properties of a building. However, even though the occupants’ control of the various systems in the building has a significant impact on the energy consumption and the indoor environment, only few studies have focused...... on the behaviour of their occupants. As a consequence, there is a need to investigate occupants’ interactions with building controls, such as opening of windows, adjustments of heating set-points, use of solar shading, etc. Some models of occupants’ interactions with operable windows do exist, but these are based...

  4. Modeling and Control of Livestock Ventilation Systems and Indoor Environments

    DEFF Research Database (Denmark)

    Wu, Zhuang; Heiselberg, Per; Stoustrup, Jakob

    2005-01-01

    The hybrid ventilation systems have been widely used for livestock barns to provide optimum indoor climate by controlling the ventilation rate and air flow distribution within the ventilated building structure. The purpose of this paper is to develop models for livestock ventilation systems and i...

  5. Quality control of computational fluid dynamics in indoor environments

    DEFF Research Database (Denmark)

    Sørensen, Dan Nørtoft; Nielsen, P. V.

    2003-01-01

    Computational fluid dynamics (CFD) is used routinely to predict air movement and distributions of temperature and concentrations in indoor environments. Modelling and numerical errors are inherent in such studies and must be considered when the results are presented. Here, we discuss modelling as...... the quality of CFD calculations, as well as guidelines for the minimum information that should accompany all CFD-related publications to enable a scientific judgment of the quality of the study....

  6. Indoor Environment Program

    International Nuclear Information System (INIS)

    Daisey, J.M.

    1993-06-01

    This paper reports progress during the year 1992 in the Indoor Environment Program in the Energy and Environment Division of Lawrence Berkeley Laboratory. Studies in the following areas are reported: energy performance and ventilation in buildings; physical and chemical characterization of indoor air pollutants; indoor radon; indoor air quality; exposure to indoor air pollutants and risk analysis. Pollutants of particular interest include: radon; volatile, semi-volatile and particulate organic compounds; and combustion emissions including environmental tobacco smoke, carbon monoxide, and nitrogen oxides

  7. Influence of heat cost allocation on occupants' control of indoor environment in 56 apartments

    DEFF Research Database (Denmark)

    Andersen, Søren; Andersen, Rune Korsholm; Olesen, Bjarne W.

    2016-01-01

    -structured interviews showed a strong influence of the heat cost allocation plan on the occupants' control strategies. Occupants whose heating bills were based on floor area focused on a healthy and comfortable indoor environment. Occupants whose heating bills were based on meter readings focused on energy conservation...... of this paper was to study the indoor environment in buildings with collective and individual heat cost allocation plans, to investigate how the heat cost allocation influenced occupant behaviour and how occupants controlled the indoor environment. The effects of the heat cost allocation type were studied...

  8. Biosynthesized silver nanoparticles to control fungal infections in indoor environments

    Science.gov (United States)

    Deyá, Cecilia; Bellotti, Natalia

    2017-06-01

    Fungi grow especially in dark and moist areas, deteriorating the indoor environment and causing infections that particularly affect immunosuppressed individuals. Antimicrobial coatings have as principal objective to prevent biofilm formation and infections by incorporation of bioactive additives. In this sense, metallic nanoparticles, such as silver, have proven to be active against different microorganisms specially bacteria. Biosynthesized method is a promising environmentally friendly option to obtain nanoparticles. The aim of this research was assess the employment of plants extracts of Aloysia triphylla (cedrón), Laurelia sempervirens (laurel) and Ruta chalepensis (ruda) to obtain silver nanoparticles to be used as an antimicrobial additive to a waterborne coating formulation. The products obtained were assessed against fungal isolates from biodeteriorated indoor coatings. The fungi were identified by conventional and molecular techniques as Chaetomium globosum and Alternaria alternate. The results revealed that the coating with silver nanoparticles obtained with L. sempervirens extract at 60 °C with a size of 9.8 nm was the most efficient against fungal biofilm development.

  9. Central automatic control or distributed occupant control for better indoor environment quality in the future

    DEFF Research Database (Denmark)

    Toftum, Jørn

    2010-01-01

    of control, as perceived by occupants, seemed more important for the prevalence of adverse symptoms and building-related symptoms than the ventilation mode per se. This result indicates that even though the development and application of new indoor environment sensors and HVAC control systems may allow...... for fully automated IEQ control, such systems should not compromise occupants' perception of having some degree of control of their indoor environment....... a discrepancy in the degree of perceived control. The database was composed of 1272 responses obtained in 24 buildings of which 15 had mechanical ventilation (997 responses) and 9 had natural ventilation (275 responses). The number of occupant-reported control opportunities was higher in buildings with natural...

  10. Occupant behaviour and control of indoor environment in Danish dwellings

    DEFF Research Database (Denmark)

    Andersen, Rune Vinther; Toftum, Jørn; Olesen, Bjarne W.

    2007-01-01

    Repeated surveys on occupant behaviour and indoor climate were carried out in Danish dwellings from September to October 2006 and again from February to March 2007. The summer survey comprised 933 respondents and the winter survey 636 respondents. The surveys were carried out by sending 5000...

  11. Central automatic control or distributed occupant control for better indoor environment quality in the future

    Energy Technology Data Exchange (ETDEWEB)

    Toftum, Joern [International Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark, DTU, Building 402, DK-2800 Lyngby (Denmark)

    2010-01-15

    Based on a database accumulated from several recent surveys of office buildings located in a temperate climate (Denmark), the effect on occupant perceptions and symptom prevalence was compared in buildings with natural and with mechanical ventilation in which earlier studies have shown a discrepancy in the degree of perceived control. The database was composed of 1272 responses obtained in 24 buildings of which 15 had mechanical ventilation (997 responses) and nine had natural ventilation (275 responses). The number of occupant-reported control opportunities was higher in buildings with natural ventilation. Analysis of occupant responses, after grouping according to categories determined by the degree of satisfaction with the perceived control, showed that it was more likely the degree of control satisfaction that affected the prevalence of adverse perceptions and symptoms. Thus, the degree of control, as perceived by occupants, seemed more important for the prevalence of adverse symptoms and building-related symptoms than the ventilation mode per se. This result indicates that even though the development and application of new indoor environment sensors and HVAC control systems may allow for fully automated IEQ control, such systems should not compromise occupants' perception of having some degree of control of their indoor environment. (author)

  12. Central automatic control or distributed occupant control for better indoor environment quality in the future

    DEFF Research Database (Denmark)

    Toftum, Jørn

    2008-01-01

    of adverse symptoms and building related symptoms than the ventilation mode per se. This result indicates that even though the development and application of new indoor environment sensors and HVAC control systems may allow for fully automated IEQ control, such systems should not compromise occupants...... in the degree of perceived control. The database was composed of 1353 responses obtained in 25 buildings of which 15 had mechanical ventilation (997 responses) and 9 had natural ventilation (275 responses). Analysis of occupant responses, after grouping according to categories determined by the degree...... of satisfaction with the perceived control, showed that the degree of control satisfaction, but rarely building category (natural vs. mechanical ventilation), affected the prevalence of adverse perceptions and symptoms. Thus, the degree of control, as perceived by occupants, was more important for the prevalence...

  13. Neural computing thermal comfort index PMV for the indoor environment intelligent control system

    Science.gov (United States)

    Liu, Chang; Chen, Yifei

    2013-03-01

    Providing indoor thermal comfort and saving energy are two main goals of indoor environmental control system. An intelligent comfort control system by combining the intelligent control and minimum power control strategies for the indoor environment is presented in this paper. In the system, for realizing the comfort control, the predicted mean vote (PMV) is designed as the control goal, and with chastening formulas of PMV, it is controlled to optimize for improving indoor comfort lever by considering six comfort related variables. On the other hand, a RBF neural network based on genetic algorithm is designed to calculate PMV for better performance and overcoming the nonlinear feature of the PMV calculation better. The formulas given in the paper are presented for calculating the expected output values basing on the input samples, and the RBF network model is trained depending on input samples and the expected output values. The simulation result is proved that the design of the intelligent calculation method is valid. Moreover, this method has a lot of advancements such as high precision, fast dynamic response and good system performance are reached, it can be used in practice with requested calculating error.

  14. Survey of occupant behaviour and control of indoor environment in Danish dwellings

    DEFF Research Database (Denmark)

    Andersen, Rune Vinther; Toftum, Jørn; Andersen, Klaus Kaae

    2009-01-01

    separately by means of multiple logistic regression in order to quantify factors influencing occupants’ behaviour. The window opening behaviour was strongly related to the outdoor temperature. The perception of the environment and factors concerning the dwelling also impacted the window opening behaviour......Repeated surveys of occupant control of the indoor environment were carried out in Danish dwellings from September to October 2006 and again from February to March 2007. The summer survey comprised 933 respondents and the winter survey 636 respondents. The surveys were carried out by sending out....... The proportion of dwellings with the heating turned on was strongly related to the outdoor temperature and the presence of a wood burning stove. The solar radiation, dwelling ownership conditions and the perception of the indoor environment also affected the use of heating. The results of the statistical...

  15. Indoor environment; Binnenmilieu

    Energy Technology Data Exchange (ETDEWEB)

    Hogeling, J.J.N.M.; Van Weele, A.M. [ISSO, Rotterdam (Netherlands); Boerstra, A.C. [BBA Boerstra Binnenmilieu Advies, Rotterdam (Netherlands); Cox, C.W.J. [TNO Bouw en Ondergrond, Delft (Netherlands); Kurvers, S.R. [Technische Universiteit Delft, Delft (Netherlands); Thierauf, I. [Universiteit Utrecht, Utrecht (Netherlands); Roelofsen, C.P.G. [Grontmij Technical Management, Amersfoort (Netherlands)

    2005-10-15

    This issue is dedicated to several aspects of the indoor environment in buildings: air quality, thermal climate, noise, light and view or panorama. [Dutch] De kwaliteit van het binnenmilieu wordt bepaald door de factoren als binnenluchtkwaliteit, thermisch binnenklimaat, geluid, daglicht, kunstlicht en uitzicht. De gemiddelde Nederlander brengt 80 tot 90% van zijn tijd binnen door. Het is dan ook van het grootste belang dat het binnenmilieu in gebouwen van een dusdanige kwaliteit is dat gebouwgebruikers zich gezond en comfortabel voelen. Het binnenmilieu omvat alle fysische (temperatuur, vochtigheid, geluid, licht), chemische en biologische factoren in een gebouw die van invloed zijn op gezondheid en welzijn van de gebruikers. Binnenmilieu is onder te verdelen in de aspecten thermisch binnenklimaat, luchtkwaliteit, geluid, licht en uitzicht. Soms vallen ook elektromagnetische velden psychologische aspecten als privacy en groenbeleving eronder. Deze ThemaTech staat geheel in het teken van binnenluchtkwaliteit, het thermische binnenklimaat, geluid, daglicht, kunstlicht en uitzicht.

  16. The thermal comfort, the indoor environment control, and the energy consumption in three types of operating rooms

    NARCIS (Netherlands)

    Melhado, M.D.A.; Beyer, P.O.; Hensen, J.L.M.; Siqueira, L.F.G.

    2005-01-01

    This research investigated the influence of three layouts of operating rooms on the indoor environment control, on thermal comfort and on energy consumption. It was used the EnergyPlus software. The parameters of the environment were described in accordance with standards. The three layouts had

  17. Research on seasonal indoor thermal environment and residents' control behavior of cooling and heating systems in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Chihye; Chun, Chungyoon [Department of Housing and Interior Design, College of Human Ecology, Graduate School, Yonsei University, Seoul (Korea)

    2009-11-15

    Indoor thermal environments and residents' control behavior of cooling and heating systems were investigated in Seoul, Korea and compared with the results of previous studies. Twenty-four houses in summer, six houses in autumn and 36 houses in winter were used in this study. The measurement of temperature, humidity and air conditioner usage behavior was carried out. The clo-value, thermal comfort, sensation and basic data of the houses were also investigated. The indoor thermal environment in the summer had a high temperature and a high humidity ratio compare to standard comfort zone. Most of the indoor thermal environments at the time of starting the air conditioner in the summer were out of the comfort zone. Some of the data recorded while the air conditioner was stopped were in the comfort zone, but in many cases the temperature was relatively higher than comfort zone. Most indoor climate distributions in the winter were in the comfort zone and the indoor climate in autumn coincided well with the criteria of the comfort zone. Compared with results of previous studies in these 25 years, indoor ambient average temperature in winter has increased and the comfort temperature has increased in the heating period and decreased in the cooling period. This result indicates that the development of an HVAC system has created an expectation of comfort for residents and has shifted their thermal comfort zone warmer in winter and cooler in summer. (author)

  18. Assessing and controlling risks from the emission of organic chemicals from construction products into indoor environments.

    Science.gov (United States)

    Brown, Veronica M; Crump, Derrick R; Harrison, Paul T C

    2013-12-01

    Construction products can be a significant source of indoor pollutants, including volatile organic compounds that may be a risk to the health and well-being of building occupants. There are currently a number of schemes for the labelling of products according to their potential to emit organic compounds. Assessment of the complex mixtures of compounds that may be released has mandated the development of test methods that allow the determination of the concentrations of the chemicals released from products in controlled test chamber environments. In response to concerns about the financial burden faced by manufacturers required to test products according to the various different labelling schemes currently in existence, the European Commission has investigated the scope for greater harmonisation. This initiative has sought to harmonise the process for the assessment of emissions data, complementing work led by the European standards organisation focussed on harmonising the test chamber procedures. The current labelling schemes have a range of requirements with respect to the number of chemicals to be quantified. A comparison of 13 schemes worldwide has identified 15 lists of target compounds, with a total of 611 chemicals occurring on at least one of the target lists. While harmonisation may clarify and perhaps simplify these requirements, at least in Europe, it can be expected that future changes to product formulations, the introduction of new products and our increasing knowledge about the potential risks to health, will require continued development of new and improved measurement techniques. There is, therefore, a particular challenge for analytical chemists to ensure the efficient provision of high quality emissions data and thereby ultimately enable effective control of risks to human health through the prevention or reduction of indoor air pollution.

  19. Study of the thermal comfort, of the energy consumption and of the indoor environment control in surgery rooms

    NARCIS (Netherlands)

    Melhado, M.D.A.; Beyer, P.O.; Hensen, J.L.M.; Siqueira, L.F.G.

    2005-01-01

    In this research were investigated the influence of different layouts of operating rooms on thermal comfort, on the indoor environment control and on energy consumption. The layouts studied were: Case 1 (a surgery room and a hallway); Case 2 (a surgery room and two hallways); and Case 3 (a surgery

  20. Psychotropic substances in indoor environments.

    Science.gov (United States)

    Cecinato, Angelo; Romagnoli, Paola; Perilli, Mattia; Patriarca, Claudia; Balducci, Catia

    2014-10-01

    The presence of drugs in outdoor air has been established, but few investigations have been conducted indoors. This study focused on psychotropic substances (PSs) at three schools, four homes and one office in Rome, Italy. The indoor drug concentrations and the relationships with the outdoor atmosphere were investigated. The optimised monitoring procedure allowed for the determination of cocaine, cannabinoids and particulate fractions of nicotine and caffeine. In-field experiments were performed during the winter, spring and summer seasons. Psychotropic substances were observed in all indoor locations. The indoor concentrations often exceeded those recorded both outdoors at the same sites and at the atmospheric pollution control network stations, indicating that the drugs were released into the air at the inside sites or were more persistent. During winter, the relative concentrations of cannabinol, cannabidiol and tetrahydrocannabinol depended on site and indoor/outdoor location at the site. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. A View Indoors, Indoor Environment Division's e-Article Series

    Science.gov (United States)

    The Indoor Environments Division has created partnership with public and private sector entities to help encourage the public to take action to minimize their risk and mitigate indoor air quality problems.

  2. Measurements of Parameters Controlling the Emissions of Organophosphate Flame Retardants in Indoor Environments.

    Science.gov (United States)

    Liang, Yirui; Liu, Xiaoyu; Allen, Matthew R

    2018-05-15

    Emission of semivolatile organic compounds (SVOCs) from source materials usually occurs very slowly in indoor environments due to their low volatility. When the SVOC emission process is controlled by external mass transfer, the gas-phase concentration in equilibrium with the material ( y 0 ) is used as a key parameter to simplify the source models that are based on solid-phase diffusion. A material-air-material (M-A-M) configured microchamber method was developed to rapidly measure y 0 for a polyisocyanurate rigid foam material containing organophosphate flame retardants (OPRFs). The emission test was conducted in 44 mL microchambers for target OPFRs, including tris(2-chloroethyl) phosphate (CASRN: 115-96-8), tris(1-chloro-2-propyl) phosphate (CASRN: 13674-84-5), and tris(1,3-dichloro-2-propyl) phosphate (CASRN: 13674-87-8). In addition to the microchamber emission test, two other types of tests were conducted to determine y 0 for the same foam material: OPFR diffusive tube sampling tests from the OPFR source foam using stainless-steel thermal desorption tubes and sorption tests of OPFR on an OPFR-free foam in a 53 L small chamber. Comparison of parameters obtained from the three methods suggests that the discrepancy could be caused by a combination of theoretical, experimental, and computational differences. Based on the y 0 measurements, a linear relationship between the ratio of y 0 to saturated vapor pressure concentration and material-phase mass fractions has been found for phthalates and OPFRs.

  3. Radon in the indoor environment

    International Nuclear Information System (INIS)

    Vanmarcke, H.

    1998-01-01

    The objectives of R and D on radon in the indoor environment at SCK-CEN is to (1) to investigate the deposition of radon progeny in the human respiratory tract by means of direct measurements as a function of aerosol conditions; to assess the radon concentrations in buildings retrospectively with volume traps. Progress and main achievements in 1997 are reported on

  4. Climate change consequences for the indoor environment

    NARCIS (Netherlands)

    Ariës, M.B.C.; Bluyssen, P.M.

    2009-01-01

    Scientists warn us about climate change and its effects on the outdoor environment. These effects can have significant consequences for the indoor environment, also in the Netherlands. Climate changes will affect different aspects of the indoor environment as well as the stakeholders of that indoor

  5. Indoor air quality: The hidden side of the indoor environment

    NARCIS (Netherlands)

    Oliveira Fernandes, E. de; Bluyssen, P.M.; Clausen, G.H.

    1996-01-01

    The physical environment can be defined and understood in manv different ways, both from its nature, e.g., thermal, accoustic, etc., or its dimension, e.g., global, local, urban, indoors. The indoor environment is much more than the space or the light effects; it is the result of a complex

  6. A novel complex air supply model for indoor air quality control via the occupant micro-environment demand ventilation

    International Nuclear Information System (INIS)

    Yang, Jie; Zhou, Bo; Jin, Maozhu; Wang, Jun; Xiong, Feng

    2016-01-01

    Protection of indoor air quality and human health can be achieved via ventilation, which has becomes one of the most important tasks for sustainable buildings. This approach also requires highly efficient and energy saving methods for modern building ventilations consisting of a set of parameters of the complex indoor system. Therefore, the advancement in understanding the characteristics of various ventilation methods is highly necessary. This study presents one novel air supply model for the complex occupant micro-environment demand control ventilations, to analyze the efficiency of various ventilation types. This model is established primarily according to the momentum and mass conservations, and goal of occupant micro-environment demand, which is a complex system with the characteristics of diversity and dynamic variation. As for different occupant densities, characteristics of outdoor air supply for controlling gaseous pollutant and three basic features of outdoor airflow supply reaching occupant micro-environment were obtained. This research shows that for various types of occupant density and storey height, the rising and descending rates of the demand outdoor airflow in mixing ventilation are higher than those under displacement ventilation conditions. In addition, since the structure is better designed and sewage flow is more efficient, the mixing ventilation also requires a much higher peak demand outdoor airflow than its counterpart. The increase of storey height will lead to a decline of pollutants in the breathing zone and the demand outdoor airflow. Fluctuations of air flow diffusion caused by the change of occupant density in architectural space, will lead to variations of outdoor airflow reaching occupant micro-environment. Accordingly, it would lead to the different peak values of demand outdoor airflow, and the difference becomes even significant if the occupant density increases. The variations of the air supply and fraction of air reaching the

  7. Indoor Environment Program - 1996 Annual Report

    Energy Technology Data Exchange (ETDEWEB)

    Indoor Environment Program

    1996-11-01

    The forty-five chemists, physicists, biologists, architects, engineers, staff, and students of the Indoor Environment Program are all working to solve the problems of indoor air quality, health, comfort, and energy use associated with the indoor environment. A common thread throughout this work is the importance of ventilation--both for its role in supporting human health and comfort as well as for its liability in requiring large amounts of energy to heat and cool it. The importance of understanding these interactions can be illustrated by two examples: the health and productivity of workers (Fisk and Rosenfeld, 1996) and the performance of sensitive equipment in clean room environments (Faulkner, et d., 1996). During the past year, we estimated the magnitudes of health and productivity gains that may be obtained by providing better indoor environments. The ratio of the potential financial benefits of improving indoor environments to the costs of the improvements ranges between 20 and 50. A second example is from our Clean Room Energy Efficiency Study: Clean rooms utilize large amounts of electricity to operate fans that recirculate air at very high flow rates through particle filters. Usually, the fans operate continuously at full speed, even when the clean room is unused. To reduce the energy use in a research clean room, the rate of air recirculation was controlled in response to real-time measurements of particle concentration. With this new control system, fan energy use decreased by 65% to 85% while maintaining particle concentrations below the allowable limits except during occasional one-minute periods. The estimated payback period for this technology is one to four years.

  8. Semivolatile organic compounds in indoor environments

    DEFF Research Database (Denmark)

    Weschler, Charles J.; Nazaroff, W.W.

    2008-01-01

    Semivolatile organic compounds (SVOCs) are ubiquitous in indoor environments, redistributing from their original sources to all indoor surfaces. Exposures resulting from their indoor presence contribute to detectable body burdens of diverse SVOCs, including pesticides, plasticizers, and flame ret...... remarkably well with levels measured in dermal hand wipes for SVOCs possessing a wide range of octanol-air partition coefficients....

  9. Design an Indoor Air Quality Controller Based on LPC2478

    Directory of Open Access Journals (Sweden)

    Shi Shuheng

    2014-07-01

    Full Text Available Indoor air quality is very important to our lives, because we spend most of our time indoor. In order to improve the air quality of indoor, this paper designs an indoor environment quality monitoring and controlling system based on ARM microcontroller LPC2478. It will do a real-time monitoring work for detecting the indoor environmental factors and comprehensively evaluate its air quality level. While the indoor air quality status is "poor", this intelligent system will automatically start the heat exchange ventilator for indoor environmental quality improvement. The results compared to traditional natural ventilation method show the better performance of proposed system.

  10. Passive Methods as a Solution for Improving Indoor Environments

    CERN Document Server

    Orosa, José A

    2012-01-01

    There are many aspects to consider when evaluating or improving an indoor environment; thermal comfort, energy saving, preservation of materials, hygiene and health are all key aspects which can be improved by passive methods of environmental control. Passive Methods as a Solution for Improving Indoor Environments endeavours to fill the lack of analysis in this area by using over ten years of research to illustrate the effects of methods such as thermal inertia and permeable coverings; for example, the use of permeable coverings is a well known passive method, but its effects and ways to improve indoor environments have been rarely analyzed.   Passive Methods as a Solution for Improving Indoor Environments  includes both software simulations and laboratory and field studies. Through these, the main parameters that characterize the behavior of internal coverings are defined. Furthermore, a new procedure is explained in depth which can be used to identify the real expected effects of permeable coverings such ...

  11. Electronic air cleaners and the indoor environment

    International Nuclear Information System (INIS)

    Krafthefer, B.

    1986-01-01

    The growing awareness over the quality of air in the indoor environment is driving the search for effective control methods for the contaminants of concern. Electronic air cleaners can control such pollutants as dust, pollen, tobacco smoke, radon decay products, and other particulates. This paper presents an examination of the various types of electronic air cleaners and their effects on indoor pollutants. It also examines the mechanism for contaminant removal, the relationship of the efficiency to the characteristics of the contaminant, and what type of contaminants can be controlled with the electronic air cleaner, with particular emphasis placed on the removal of radon decay products. From a study on radon product removal in residences, the electronic air cleaner was found to have an efficiency of up to 70%. Not only was there a reduction in the residential working level, but the fluctuations in the working level were also reduced. With this information, they can better understand how to solve the air treatment problem of the inhabited space. 17 references, 8 figures

  12. How indoor environment affects performance

    DEFF Research Database (Denmark)

    Wyon, David Peter; Wargocki, Pawel

    2013-01-01

    , in the form of answers to 40 frequently asked questions. Our answers are based on the results of behavioral experiments conducted to date. We offer no opinions on long-term health effects of indoor environmental quality. We provide some references to relevant sources, but there is not enough space for all...

  13. Assessment of indoor environment of buildings

    Energy Technology Data Exchange (ETDEWEB)

    Fan, Y; Kovanen, K [VTT Building Technology, Espoo (Finland). Indoor Environment and Systems

    1996-12-31

    The synthetical assessment of indoor environment has become world-wide topic in recent years. Many research evidences have shown that the quality of indoor air is a multi-factor influenced issue. Building Research Establishment (BRE) in United Kingdom has worked out a series of assessing methods for different kinds of buildings. Whereas, in Finland, National Building Code of Finland has been used for many years. The comparison between the two approaches in assessing indoor air quality will be addressed in this presentation. Each issue considered in the above two approaches is discussed by referring the recent research highlights. (author)

  14. Assessment of indoor environment of buildings

    Energy Technology Data Exchange (ETDEWEB)

    Fan, Y.; Kovanen, K. [VTT Building Technology, Espoo (Finland). Indoor Environment and Systems

    1995-12-31

    The synthetical assessment of indoor environment has become world-wide topic in recent years. Many research evidences have shown that the quality of indoor air is a multi-factor influenced issue. Building Research Establishment (BRE) in United Kingdom has worked out a series of assessing methods for different kinds of buildings. Whereas, in Finland, National Building Code of Finland has been used for many years. The comparison between the two approaches in assessing indoor air quality will be addressed in this presentation. Each issue considered in the above two approaches is discussed by referring the recent research highlights. (author)

  15. Behaviors of radon in indoor environment

    International Nuclear Information System (INIS)

    Mochizuki, Sadamu; Shimo, Michikuni.

    1987-01-01

    The source of radon ( 222 Rn) in the atmosphere is radioactive nuclide, uranium ( 238 U), which exists fairly common throughout the earth's crust. Radium ( 226 Ra) descended from uranium produce radon ( 222 Rn) of noble gas by decay. After formation in the ground, radon diffuses into the atmosphere. Without exception radon decay products are heavy metals which soon become attached to natural aerosols. Therefore, radon and its daughters (decay products) appear also in indoor environment, and generally, their concentration levels become higher than that of outdoor air due to build-up effects in the closed indoor environments. With the progress of the study on the influence of radon and its daughers on human health, it has become clear that they act effectively as an exciting cause of lung cancer. So, the study on the risk evaluation of them in room air has become to be very important. Concequently, the behaviors of radon and its daughters in indoor environment, first of all, should be studied in detail for the accurate estimation of the risk caused by them. In this special edition, fundamental characteristics of radon and its daughters, some measuring methods, theoretical considerations and some observational evidences obtained from various circumstances of indoor environment are described inorder to grasp and understand the behaviors of radon and its daughters in the indoor environment. (author)

  16. The thermal comfort, the indoor environment control, and the energy consumption in three types of operating rooms

    Energy Technology Data Exchange (ETDEWEB)

    Melhado, M.A.; Hensen, J.M. [Eindhoven Technical Univ., Eindhoven (Netherlands). Center for Building and Systems; Beyer, P.O. [Rio Grande do Sul Federal Univ., Rio Grande do Sul (Brazil). Dept. of Mechanical Engineering; Siqueira, L.F.G. [Sao Paulo Univ., Sao Paulo (Brazil). Dept. of Epidemiology

    2005-07-01

    This paper investigated the influence of layout on the thermal comfort, indoor environment and energy consumption in different types of operating rooms (OR) in Brazil. Three different types of layout were evaluated: (1) a hallway and a surgery room; (2) a clean hallway, an operating room, and another hallway; and (3) a hallway, an anteroom and an operating room. The dimensions of the environments were established by Ministerio da Saude regulations. Modeling was achieved with EnergyPlus software. Orthopaedic and abdominal surgeries were considered. The type of surgery defined the dimensions of the environment, patient requirements and the number of people, as well as the amount and type of equipment and hours spent in the ORs, and these parameters were used in the simulation. Two types of software were used: Cterm version 2002 and EnergyPlus version 1.03. The results in of the simulation were in agreement with previous experiments in the literature. Cterm was used to calculate the levels of activity of different people, the thermal resistance of clothes and work activity. Data included the relative humidity and wind speed. The data were then used in the EnergyPlus simulation. Heat source variables included medical equipment, lighting and cleaning activities, as well as temperatures for neighbouring environments and climatic conditions. Results indicated that out of 60 cases simulated, 88 per cent presented a relative humidity above acceptable limits. Dehumidifiers were added to the simulation, which in turn influenced overall energy consumption. Patient discomfort was measured, as well the comfort levels of the anesthesiologist. Details of annual energy consumption for the different scenarios were presented. It was concluded that layout had a significant impact on the thermal comfort of the ORs, as well as on relative humidity and temperature. Case 2 presented the most significant advantages relating to environmental control. However, case 2 was also the most

  17. Panels Manufactured from Vegetable Fibers: An Alternative Approach for Controlling Noises in Indoor Environments

    Directory of Open Access Journals (Sweden)

    Leopoldo Pacheco Bastos

    2012-01-01

    Full Text Available Noise control devices such as panels and barriers, when of high efficiency, generally are of difficult acquisition due to high costs turning in many cases their use impracticable, mainly for limited budget small-sized companies. There is a huge requirement for new acoustic materials that have satisfactory performance, not only under acoustic aspect but also other relevant ones and are of low cost. Vegetable fibers are an alternative solution when used as panels since they promise satisfactory acoustic absorption, according to previous researches, exist in abundance, and derive from renewable sources. This paper, therefore, reports on the development of panels made from vegetable fibers (coconut, palm, sisal, and açaí, assesses their applicability by various experimental (flammability, odor, fungal growth, and ageing tests, and characterize them acoustically in terms of their sound absorption coefficients on a scale model reverberant chamber. Acoustic results point out that the aforementioned fiber panels play pretty well the role of a noise control device since they have compatible, and in some cases, higher performance when compared to commercially available conventional materials.

  18. Indoor environment program. 1994 annual report

    Energy Technology Data Exchange (ETDEWEB)

    Daisey, J.M.

    1995-04-01

    Buildings use approximately one-third of the energy consumed in the United States. The potential energy savings derived from reduced infiltration and ventilation in buildings are substantial, since energy use associated with conditioning and distributing ventilation air is about 5.5 EJ per year. However, since ventilation is the dominant mechanism for removing pollutants from indoor sources, reduction of ventilation can have adverse effects on indoor air quality, and on the health, comfort, and productivity of building occupants. The Indoor Environment Program in LBL`s Energy and Environment Division was established in 1977 to conduct integrated research on ventilation, indoor air quality, and energy use and efficiency in buildings for the purpose of reducing energy liabilities associated with airflows into, within, and out of buildings while maintaining or improving occupant health and comfort. The Program is part of LBL`s Center for Building Science. Research is conducted on building energy use and efficiency, ventilation and infiltration, and thermal distribution systems; on the nature, sources, transport, transformation, and deposition of indoor air pollutants; and on exposure and health risks associated with indoor air pollutants. Pollutants of particular interest include radon; volatile, semivolatile, and particulate organic compounds; and combustion emissions, including environmental tobacco smoke, CO, and NO{sub x}.

  19. Indoor environment program - 1995 annual report

    Energy Technology Data Exchange (ETDEWEB)

    Daisey, J.M.

    1996-06-01

    Buildings use approximately one-third of the energy consumed in the United States. The potential energy savings derived from reduced infiltration and ventilation in buildings are substantial, since energy use associated with conditioning and distributing ventilation air is about 5.5 EJ per year. However, since ventilation is the dominant mechanism for removing pollutants from indoor sources, reduction of ventilation can have adverse effects on indoor air quality, and on the health, comfort, and productivity of building occupants. The Indoor Environment Program in LBL`s Energy and Environment Division was established in 1977 to conduct integrated research on ventilation, indoor air quality, and energy use and efficiency in buildings for the purpose of reducing energy liabilities associated with airflows into, within, and out of buildings while maintaining or improving occupant health and comfort. The Program is part of LBL`s Center for Building Science. Research is conducted on building energy use and efficiency, ventilation and infiltration, and thermal distribution systems; on the nature, sources, transport, transformation, and deposition of indoor air pollutants; and on exposure and health risks associated with indoor air pollutants. Pollutants of particular interest include radon; volatile, semivolatile, and particulate organic compounds; and combustion emissions, including environmental tobacco smoke, CO, and NO{sub x}.

  20. A research on indoor environments of an office building by occupants' subjective evaluation

    International Nuclear Information System (INIS)

    Moon, S.W.; Kim, T.W.; Hong, W.H.

    2008-01-01

    Since modern workers spend more than 80 per cent of their time in indoor environments, it is important to make a comfortable indoor environment in order to maintain occupational health and to improve work efficiency and productivity. Not only are new offices bigger than ever before, the internal heat and air are controlled by a central air conditioning system, which do not allow occupant control. This study evaluated indoor environments of office buildings in an effort to understand how the indoor environment influences work efficiency. The study involved the use of a survey questionnaire to obtain occupants' subjective evaluation of indoor working environments of an office building in terms of thermal comfort, lighting, noise and air quality. The survey results indicated that the indoor environment interrupts the work of many workers. Neck, eye, skin and nasal symptoms were found to be the symptoms most related to the indoor environment, with temperature and humidity posing the greatest challenge. 9 refs., 9 tabs., 7 figs

  1. Barcode based localization system in indoor environment

    Directory of Open Access Journals (Sweden)

    Ľubica Ilkovičová

    2014-12-01

    Full Text Available Nowadays, in the era of intelligent buildings, there is a need to create indoornavigation systems, what is steadily a challenge. QR (Quick Response codesprovide accurate localization also in indoor environment, where other navigationtechniques (e.g. GPS are not available. The paper deals with the issues of posi-tioning using QR codes, solved at the Department of Surveying, Faculty of CivilEngineering SUT in Bratislava. Operating principle of QR codes, description ofthe application for positioning in indoor environment based on OS Android forsmartphones are described.

  2. Ventilation strategies and indoor environment in classrooms

    DEFF Research Database (Denmark)

    Zhang, Chen; Liu, Li

    2017-01-01

    Compared with the other building types, the school building has much higher occupancy density and ventilation demand. In Demark, most of the school buildings are ventilated by natural manner. There is a risk of poor indoor environment associated with the lack of ventilation system or insufficient...

  3. Fungal pollution of indoor environments and its management.

    Science.gov (United States)

    Haleem Khan, A A; Mohan Karuppayil, S

    2012-10-01

    Indoor environments play important roles in human health. The health hazards posed by polluted indoor environments include allergy, infections and toxicity. Life style changes have resulted in a shift from open air environments to air tight, energy efficient, environments, in which people spend a substantial portion of their time. Most indoor air pollution comes from the hazardous non biological agents and biological agents. Fungi are ubiquitous in distribution and are a serious threat to public health in indoor environments. In this communication, we have reviewed the current status on biotic indoor air pollution, role of fungi as biological contaminants and their impact on human health.

  4. Human response to combined indoor environment exposures

    DEFF Research Database (Denmark)

    Toftum, Jørn

    2002-01-01

    Most thermal comfort standards and guidelines presume sedentary, light activity and a neutral overall thermal sensation when predicting local thermal discomfort. In addition, current standards specify criteria for separate aspects of the indoor environment, e.g. thermal climate, air quality...... or noise, with only little consideration of possible interactions between the different types of exposure. The studies summarized in this article found a clear impact of activity and overall thermal sensation on human sensitivity to air movement, whereas no interaction effects of exposure to several local...... thermal discomfort factors were observed. Limited evidence was found of significant interactions between different aspects of the indoor environment. Only for the effect of air temperature and air humidity on sensory air quality were well-estabished relationships available....

  5. Autonomous Flight in Unknown Indoor Environments

    OpenAIRE

    Bachrach, Abraham Galton; He, Ruijie; Roy, Nicholas

    2009-01-01

    This paper presents our solution for enabling a quadrotor helicopter, equipped with a laser rangefinder sensor, to autonomously explore and map unstructured and unknown indoor environments. While these capabilities are already commodities on ground vehicles, air vehicles seeking the same performance face unique challenges. In this paper, we describe the difficulties in achieving fully autonomous helicopter flight, highlighting the differences between ground and helicopter robots that make it ...

  6. Creating the perfect indoor environment

    Energy Technology Data Exchange (ETDEWEB)

    Kilbridge, K.

    2002-08-01

    The virtues of radiant heating over convection heating systems is extolled, by outlining the salient features of the various forms of radiant heating systems. Among those described are thermal storage systems, radiant ceiling panels, suspended ceiling systems, commercial and industrial systems, and floor warming systems. There are two types of thermal storage systems; one is similar in appearance to a convection system that is installed in each room at the wall. The other is installed in soil or sand under the concrete slab building foundation. Both systems take advantage of reduced electrical rates applicable to power drawn during off-peak hours. Radiant ceiling panels are comprised of gypsum panels that fit between the ceiling joists above a finished ceiling. Regardless of the particular model, these systems are completely concealed; there are no radiators or registers to interfere with furniture placement or decorating. They eliminate cold and hot spots, maintaining a temperature variation between ceiling and floor at less than one degree C. Suspended ceiling panels sit in the suspended ceiling grid work and are connected using industry-standard electrical box and connectors. They are particularly suitable for office buildings, basements, etc. Commercial and industrial systems are used to provide higher output, to spot-heat areas, or perimeter of buildings where the heat loss load is high. Panels come in various sizes and can be connected to an energy management system, allowing complete management of the environment levels for every office on every floor. Floor warming systems are most frequently used in kitchens, bathrooms, entrance ways and foyers. The central energy source is hydronic, which heats up the liquid heat transfer agent. The pipes or tubing fixed to the plywood flooring are embedded in a thin layer of concrete to radiate upwards through the marble, ceramic tile or stone outer flooring.

  7. Thermal indoor environment and energy consumption in a plus-energy house: cooling season measurements

    DEFF Research Database (Denmark)

    Kazanci, Ongun Berk; Olesen, Bjarne W.

    2015-01-01

    indoor environment. For the energy consumption of the HVAC system, air-to-brine heat pump, mixing station and controller of the radiant floor, and the air handling unit were considered. The measurements were analyzed based on the achieved indoor environment category (according to EN 15251...... the floor cooling system) and increasing the ventilation rate provided a better thermal indoor environment but with increased energy consumption. The thermal indoor environment and energy performance of the house can be improved with decreased glazing area, increased thermal mass, installation of solar...

  8. Healthy indoors : achieving healthy indoor environments in Canada : Final report

    International Nuclear Information System (INIS)

    Anon

    2002-01-01

    A large proportion of the lives of Canadians is spent indoors, whether in vehicles, restaurants, shopping malls, offices or houses. The health of people working and living in those indoor settings might be damaged a a result, despite best efforts. Indoor pollution has been identified as one of the most serious risks to human health, according to numerous leading authorities, among them the American Lung Association, the United States Environmental Protection Agency, the Canada Mortgage and Housing Corporation (CMHC). A large number of cancer deaths are attributed to indoor pollution each year in the United States, as well as respiratory health problems. A causal link between certain indoor exposures and the development and provocation of asthma was established recently in a report on asthma and indoor air quality published by the National Academy of Sciences/Institute of Medicine. Exposure to indoor pollutants has also resulted in thousands of children experiencing elevated blood lead levels. Not enough attention is paid in Canada to pollution in buildings by government agencies, corporations and other non-governmental organizations and citizens. Not much seems to have changed in the past thirty years. An ambitious strategy by Pollution Probe was described in this document, listing the initial goals and measures required to achieve those goals. The creation of Healthy Indoors Partnership (HIP) was proposed to regroup all the stakeholders under the same umbrella. refs., tabs

  9. New indoor environment chambers and field experiment offices for research on human comfort, health and productivity

    DEFF Research Database (Denmark)

    Toftum, Jørn; Langkilde, Gunnar; Fanger, Povl Ole

    2004-01-01

    The article describes three new indoor environment chambers, a new laboratory for the study of air movement in spaces and five offices for controlled environment exposures of human subjects in field experiments at the International Centre for Indoor Environment and Energy, Technical University of...... of Denmark. Together with three older chambers, the Centre now has at its disposal 12 spaces for studying indoor environments and their impact on human comfort, health and productivity.......The article describes three new indoor environment chambers, a new laboratory for the study of air movement in spaces and five offices for controlled environment exposures of human subjects in field experiments at the International Centre for Indoor Environment and Energy, Technical University...

  10. Modeling, Estimation and Control of Indoor Climate in Livestock Buildings

    DEFF Research Database (Denmark)

    Wu, Zhuang

    The main objective of this research is to design an efficient control system for the indoor climate of a large-scale partition-less livestock building, in order to maintain a healthy, comfortable and economically energy consuming indoor environment for the agricultural animals and farmers. In thi...... scale livestock buildings, and could be considered as an alternative solution to the current used decentralized PID controller.......The main objective of this research is to design an efficient control system for the indoor climate of a large-scale partition-less livestock building, in order to maintain a healthy, comfortable and economically energy consuming indoor environment for the agricultural animals and farmers....... With necessary assumptions and simplifications, the dominant air flow distributions are investigated and the phenomenon of horizontal variations is well depicted. The designed entire control system consists of an outer feedback closed-loop dynamic controller and an inner feed-forward redundancy optimization...

  11. Indoor environment program: FY 1988 annual report

    International Nuclear Information System (INIS)

    1989-03-01

    The Indoor Environment Program examines the scientific issues associated with the design and operation of buildings to optimize energy performance and occupant comfort and health. Optimizing occupant health and comfort is addressed in various ways by groups within the Program. To examine energy flow through all elements of the building shell, the Energy Performance of Buildings Group measures air infiltration rates, studies thermal characteristics of structural elements, and develops simplified models of the behavior of complete buildings. Potential savings in the infiltration area are great

  12. Evaluation of the Indoor Environment in the Comfort Houses

    DEFF Research Database (Denmark)

    Brunsgaard, Camilla; Heiselberg, Per; Knudstrup, Mary-Ann

    2012-01-01

    and in a process of doing so, it is important to maintain a good and healthy indoor environment and not on the expense of it. One way of saving energy is to build passive houses. This paper presents the result of a case study of some of the first certified passive houses in Denmark, called the Comfort Houses....... The paper evaluates the indoor environment through both quantitative measurements in the houses and qualitative interviews with the occupants about their experiences of the indoor environment. Two set of knowledge which together gives a more complete and holistic picture of the indoor environment. The study...

  13. Recognition, evaluation, and control of indoor air pollution

    International Nuclear Information System (INIS)

    Chastain, B.

    1993-01-01

    Indoor air pollution is typically associated with terms sick building syndrome, tight building syndrome, building related illness, and problem building. Indoor air pollution is a relatively new public health concern (approximately 15 years old) although this issue is an age-old problem dating back to prehistoric times when humans came to live indoors. This presentation summarizes indoor air quality issues in order to provide you with usable information concerning the recognition and evaluation of indoor air quality (IAQ) problems and the subsequent control measures which can be used for maintaining or improving the indoor air environment for better occupant health and comfort control. Why has the subject become so vocalized in the last fifteen years? Why the sudden interest and awareness concerning indoor air quality issues? During the last half of the 1970's and all of the 1980's, buildings were built or remodeled to minimize air handling, heating, and cooling costs, often limiting the amount of outside air brought into the buildings to near minimums. Paralleling these developments, complaints related to modern buildings increased. The new terms tight building syndrome, sick building syndrome, and indoor air quality became widely used by health and safety professionals and subsequently by newspaper columnist and the general public

  14. Indoor radon and decay products: Concentrations, causes, and control strategies

    Energy Technology Data Exchange (ETDEWEB)

    Nero, A.V.; Gadgil, A.J.; Nazaroff, W.W.; Revzan, K.L.

    1990-11-01

    This report is another in the on going technical report series that addresses various aspects of the DOE Radon Research Program. It provides an overview of what is known about the behavior of radon and its decay products in the indoor environment and examines the manner in which several important classes of factors -- structural, geological, and meteorological -- affect indoor radon concentrations. Information on US indoor radon concentrations, currently available monitoring methods and novel radon control strategies are also explored. 238 refs., 22 figs., 9 tabs.

  15. External eye symptoms in indoor environments.

    Science.gov (United States)

    Wolkoff, P

    2017-03-01

    Eye irritation, for example dry or irritated eyes, is generally among top three reported symptoms in office-like environments, in particular among workplaces with cognitive demanding visual display unit (VDU) work. The symptoms are especially among middle and advanced ages and particularly among women more than men. The symptoms are also among the most commonly reported complaints in the eye clinic. To be in a position to interpret the high prevalence of eye symptoms, a multidisciplinary and integrated approach is necessary that involves the external eye physiology (separate from internal eye effects), eye diseases (evaporative dry eye (DE), aqueous-deficient DE, and gland dysfunctions), and risk factors that aggravate the stability of precorneal tear film (PTF) resulting in hyperosmolarity and initiation of inflammatory reactions. Indoor environmental, occupational and personal risk factors may aggravate the PTF stability; factors such as age, contact lenses, cosmetics, diet, draft, gender, low humidity and high temperature, medication, outdoor and combustion pollutants, and VDU work. Psychological stressors may further influence the reporting behavior of eye symptoms. The impact of the risk factors may occur in a combined and exacerbating manner. © 2016 The Authors. Indoor Air published by John Wiley & Sons Ltd.

  16. Indoor environment and pupils' health in primary schools

    NARCIS (Netherlands)

    van Dijken, F; Bronswijk, van J.E.M.H.; Sundell, J.

    2006-01-01

    Dutch children are legally bound to spend 15% of their time in a school setting. The indoor environment in Dutch primary schools is known to be substandard. However, it is unclear to what extent the health of pupils is affected by the indoor school environment. The paper aims to assess the

  17. Spatial subdivision of complex indoor environments for 3D indoor navigation

    NARCIS (Netherlands)

    Diakite, A.A.; Zlatanova, S.

    2018-01-01

    As we realize that we spend most of our time in increasingly complex indoor environments, applications to assist indoor activities (e.g. guidance) have gained a lot of attention in the recent years. The advances in ubiquitous computing made possible the development of several spatial models

  18. Mercury persistence in indoor environments in the Amazon region, Brazil.

    Science.gov (United States)

    Bastos, Wanderley Rodrigues; Fonseca, Márlon de Freitas; Pinto, Fernando Neves; Rebelo, Mauro de Freitas; dos Santos, Sérgio Silva; da Silveira, Ene Glória; Torres, João Paulo Machado; Malm, Olaf; Pfeiffer, Wolfgang Christian

    2004-10-01

    We evaluated the indoor atmospheric Hg contamination in gold trade shops in two Brazilian cities of the Legal Amazon area using the Spanish moss (Tillandsia usneoides, Bromeliaceae) as a sentinel species. Plants inside plastic cages were exposed to a controlled atmosphere to evaluate the rate of Hg retention over time and then distributed in several stores with different characteristics to enable a relative comparison. Hg concentrations were determined by cold vapor atomic absorption spectrophotometry. Plants exposed in active stores with good air circulation exhibited lower levels. Ex-gold trade shops that were kept closed for long periods exhibited higher values. Stores that have been restored before being transformed into new businesses exhibited lower values than nonrestored ones. Direct measurements suggest that indoor Hg air concentrations were below the threshold limit recommended by the World Health Organization to occupational exposure; nevertheless, restoring ex-gold trade shops could ensure a healthier working environment.

  19. Mercury persistence in indoor environments in the Amazon Region, Brazil

    International Nuclear Information System (INIS)

    Bastos, W.R.; Freitas Fonseca, M. de; Pinto, F.N.; Freitas Rebelo, Mauro de; Silva dos Santos, Sergio; Gloria da Silveira, Ene; Torres, J.P.M.; Malm, Olaf; Pfeiffer, W.C.

    2004-01-01

    We evaluated the indoor atmospheric Hg contamination in gold trade shops in two Brazilian cities of the Legal Amazon area using the Spanish moss (Tillandsia usneoides, Bromeliaceae) as a sentinel species. Plants inside plastic cages were exposed to a controlled atmosphere to evaluate the rate of Hg retention over time and then distributed in several stores with different characteristics to enable a relative comparison. Hg concentrations were determined by cold vapor atomic absorption spectrophotometry. Plants exposed in active stores with good air circulation exhibited lower levels. Ex-gold trade shops that were kept closed for long periods exhibited higher values. Stores that have been restored before being transformed into new businesses exhibited lower values than nonrestored ones. Direct measurements suggest that indoor Hg air concentrations were below the threshold limit recommended by the World Health Organization to occupational exposure; nevertheless, restoring ex-gold trade shops could ensure a healthier working environment

  20. Experimental evaluation on energy performance of innovative clean air heat pump for indoor environment control in summer and winter seasons

    DEFF Research Database (Denmark)

    Nie, Jinzhe; Fang, Lei; Olesen, Bjarne W.

    2014-01-01

    Based on the air purification capacity of regenerative silica gel rotor, an innovative clean air heat pump (CAHP) was designed, developed and investigated through experimental studies. The CAHP integrated air purification, dehumidification and heating/cooling in one unit. A prototype of the CAHP...... was developed. Laboratory experimental studies were conducted to investigate its energy performance under different outdoor climates including cold, mild-cold, mild-hot and extremely hot and humid climates. The energy performance of the CAHP was then evaluated by comparing with a conventional air source heat...... pump. The results showed that to keep same indoor air quality, the CAHP could save substantial amount of energy. For example, compared to the conventional air source heat pump, the CAHP could save up to 59%, 40%, 30% of electricity for ventilation and air conditioning in a test room in summer...

  1. Controlling Indoor Air Pollution from Moxibustion

    Directory of Open Access Journals (Sweden)

    Chung-Yen Lu

    2016-06-01

    Full Text Available Indoor air quality (IAQ control of hospitals plays a critical role in protecting both hospital staffs and patients, particularly those who are highly susceptible to the adverse effects of indoor noxious hazards. However, moxibustion in outpatient departments (OPDs of traditional Chinese medicine (TCM may be a source of indoor air pollution in hospitals. Some studies have investigated indoor air pollution during moxibustion in Chinese medicine clinics (CMCs and moxibustion rooms, demonstrating elevated air pollutants that pose a threat to the health of medical staff and patients. Our study investigated the indoor air pollutants of indoor carbon dioxide (CO2, carbon monoxide (CO, formaldehyde (HCHO, total volatile organic compounds (TVOCs, airborne particulate matter with a diameter of ≤10 µm (PM10 and ≤2.5 µm (PM2.5 during moxibustion in an acupuncture and moxibustion room of the OPD in a hospital in Taipei. To evaluate the different control strategies for indoor air pollution from moxibution, a comparison of air pollutants during moxibution among the methods of using alternative old moxa wools, local exhaust ventilation and an air cleaner was conducted. In this study, burning alternative old moxa wools for moxibustion obviously reduced all gaseous pollutants except for aerosols comparing burning fresh moxa wools. Using local exhaust ventilation reduced most of the aerosols after burning moxa. We also found that using an air cleaner was inefficient for controlling indoor air pollutants, particularly gaseous pollutants. Therefore, combining replacing alternative old moxa wools and local exhaust ventilation could be a suitable design for controlling indoor air pollution during moxibustion therapy.

  2. How to Create Healthy Indoor Environments in Schools

    Science.gov (United States)

    Rhodes, Diane; Di Nella, Frank

    2012-01-01

    A green and healthy indoor environment should be a fundamental concern in the place where kids learn and grow. Good indoor air quality (IAQ) has been shown to have positive effects on student and staff productivity, performance, comfort and attendance. Conversely, poor IAQ in classrooms--caused by mold and moisture issues, problems with HVAC…

  3. Characterization of microorganisms in indoor environments

    Energy Technology Data Exchange (ETDEWEB)

    Lignell, U.

    2008-07-01

    In indoor environments, moisture damage and related microbial growth are associated with adverse health effects. In this thesis, five studies were conducted to characterize how the microbial conditions in indoor environments are affected by the use of the building, by the presence of moisture damage, renovation of that damage, and time. A special focus was placed on the development of detection methods of an interesting bacterial genus, Streptomyces. The effects of nutrients on the growth of streptomycetes were studied on 26 media. In addition, pH effects were examined with seven media. The pH range was 4.0 to 11.5 in intervals of 1.5 units. Glucose and tryptone allowed good growth of streptomycetes. The widely used tryptone yeast extract glucose (TYG) medium and tryptone soy agar (TSA) proved to be suitable media for the growth of streptomycetes isolated from indoor environments. The pH range for growth and sporulation was large, depended on nutrients, and was not a species-specific property. Microbial concentrations were analyzed in eight school kitchens and compared with other parts of the schools. The airborne microbial concentrations in the kitchens were lower than those encountered in the other parts of the schools. The effects of moisture damage on microbial flora in indoor environments were investigated in eight schools including school kitchens by air and surface sampling, in two schools two years before renovation via air samples and in 81 homes with house dust samples. It was found that moisture damage elevated microbial concentrations. In the moisture-damaged schools (index schools, n=6), culturable airborne microbial concentrations were higher than in the reference schools (n=2) and this was also true for kitchen facilities. Microbial concentrations were higher on moisture-damaged surfaces, than on undamaged surfaces. In addition, high concentrations of microbes, especially bacteria, were detected from undamaged surfaces in moisture-damaged kitchens

  4. Research on the Implementation of Technological Measures for Controlling Indoor Environmental Quality in Green Residential Buildings

    Science.gov (United States)

    Wang, Ruozhu; Liu, Pengda; Qian, Yongmei

    2018-02-01

    This paper analyzes the design technology of controlling indoor quality in engineering practice, it is proposed that, in framework system of green residential building design, how to realize the design idea of controlling the indoor environment quality, and the design technology with feasibility, including the sunshine and lighting, indoor air quality and thermal environment, sound insulation and noise reduction measures, etc.. The results of all will provide a good theoretical supportting for the design of green residential building.

  5. Indoor air quality in public utility environments-a review.

    Science.gov (United States)

    Śmiełowska, Monika; Marć, Mariusz; Zabiegała, Bożena

    2017-04-01

    Indoor air quality has been the object of interest for scientists and specialists from the fields of science such as chemistry, medicine and ventilation system design. This results from a considerable number of potential factors, which may influence the quality of the broadly understood indoor air in a negative way. Poor quality of indoor air in various types of public utility buildings may significantly affect an increase in the incidence of various types of civilisation diseases. This paper presents information about a broad spectrum of chemical compounds that were identified and determined in the indoor environment of various types of public utility rooms such as churches, museums, libraries, temples and hospitals. An analysis of literature data allowed for identification of the most important transport paths of chemical compounds that significantly influence the quality of the indoor environment and thus the comfort of living and the health of persons staying in it.

  6. Variation of indoor radon concentration and ambient dose equivalent rate in different outdoor and indoor environments

    Energy Technology Data Exchange (ETDEWEB)

    Stojanovska, Zdenka; Janevik, Emilija; Taleski, Vaso [Goce Delcev University, Faculty of Medical Sciences, Stip (Macedonia, The Former Yugoslav Republic of); Boev, Blazo [Goce Delcev University, Faculty of Natural and Technical Sciences, Stip (Macedonia, The Former Yugoslav Republic of); Zunic, Zora S. [University of Belgrade, Institute of Nuclear Sciences ' ' Vinca' ' , Belgrade (Serbia); Ivanova, Kremena; Tsenova, Martina [National Center of Radiobiology and Radiation Protection, Sofia (Bulgaria); Ristova, Mimoza [University in Ss. Cyril and Methodius, Faculty of Natural Sciences and Mathematic, Institute of Physics, Skopje (Macedonia, The Former Yugoslav Republic of); Ajka, Sorsa [Croatian Geological Survey, Zagreb (Croatia); Bossew, Peter [German Federal Office for Radiation Protection, Berlin (Germany)

    2016-05-15

    Subject of this study is an investigation of the variations of indoor radon concentration and ambient dose equivalent rate in outdoor and indoor environments of 40 dwellings, 31 elementary schools and five kindergartens. The buildings are located in three municipalities of two, geologically different, areas of the Republic of Macedonia. Indoor radon concentrations were measured by nuclear track detectors, deployed in the most occupied room of the building, between June 2013 and May 2014. During the deploying campaign, indoor and outdoor ambient dose equivalent rates were measured simultaneously at the same location. It appeared that the measured values varied from 22 to 990 Bq/m{sup 3} for indoor radon concentrations, from 50 to 195 nSv/h for outdoor ambient dose equivalent rates, and from 38 to 184 nSv/h for indoor ambient dose equivalent rates. The geometric mean value of indoor to outdoor ambient dose equivalent rates was found to be 0.88, i.e. the outdoor ambient dose equivalent rates were on average higher than the indoor ambient dose equivalent rates. All measured can reasonably well be described by log-normal distributions. A detailed statistical analysis of factors which influence the measured quantities is reported. (orig.)

  7. Research review: Indoor air quality control techniques

    International Nuclear Information System (INIS)

    Fisk, W.J.

    1986-10-01

    Techniques for controlling the concentration of radon, formaldehyde, and combustion products in the indoor air are reviewed. The most effective techniques, which are generally based on limiting or reducing indoor pollutant source strengths, can decrease indoor pollutant concentrations by a factor of 3 to 10. Unless the initial ventilation rate is unusually low, it is difficult to reduce indoor pollutant concentrations more than approximately 50% by increasing the ventilation rate of an entire building. However, the efficiency of indoor pollutant control by ventilation can be enhanced through the use of local exhaust ventilation near concentrated sources of pollutants, by minimizing short circuiting of air from supply to exhaust when pollutant sources are dispersed and, in some situations, by promoting a displacement flow of air and pollutants toward the exhaust. Active air cleaning is also examined briefly. Filtration and electrostatic air cleaning for removal of particles from the indoor air are the most practical and effective currently available techniques of air cleaning. 49 refs., 7 figs

  8. Parents and Students and Healthy Indoor School Environments

    Science.gov (United States)

    School-aged children spend a great deal of time inside school buildings. Parents can play an important role in creating healthy indoor school environments. Parents and students alike can make a powerful case for protecting health in schools.

  9. Criteria For Specifikation Of The Indoor Environment Of Active House

    DEFF Research Database (Denmark)

    Foldbjerg, Peter; Hansen, Ellen Kathrine; Duer, Karsten

    2011-01-01

    The Active House Alliance has been formed by companies and organisations in the building design, components and construction industry to with the intention to improve the quality of the built environment through a balanced focus on indoor environment, energy and environment – and where the aspects...... of human health and wellbeing will be specifically considered. This paper presents the first version of the Active House specification for indoor environment for residential buildings (where specifications for energy and environment also exist). It is based on the EN 15251 philosophy, and with specific...... requirements to daylight, thermal environment, IAQ and acoustics. Requirements have been tightened compared to EN 15251, and will necessitate performance simulations....

  10. In search of a common European approach to a healthy indoor environment

    DEFF Research Database (Denmark)

    Adan, Olaf C G; Ng-A-Tham, Julie; Hanke, Wojtek

    2007-01-01

    Increasingly, policymakers in Europe and around the world are realizing the importance of healthy indoor environments for public health. Certain member states of the European Union (EU) have already achieved successes in improving indoor environmental quality, such as controlling certain...... barriers: a) the subsidiarity principle in EU policymaking, introducing decentralization of decision making to the member states; b) fragmentation of the topic of the indoor environment; c) the differences in climate and governance among different member states that make a common policy difficult; and d...

  11. Indoor Thermal Environment in Tropical Climate Residential Building

    Directory of Open Access Journals (Sweden)

    Jamaludin Nazhatulzalkis

    2014-01-01

    Full Text Available Indoor thermal environment is one of the criteria in sustainable building. This criterion is important in ensuring a healthy indoor environment for the occupants. The consideration of environmental concerns at the early design stage would effectively integrate the sustainability of the building environment. Global climate changes such as global warming do affect human comfort since people spend most of their time and activities in the building. The increasing of urban population required additional housing for households, as well as places to shop, office and other facilities. Occupants are now more conscious the importance of sustainability for a better quality of life. Good thermal environment is essential for human wellness and comfort. A residential environment will influence residents’ health and safety. The global warming increase the earth’s temperature and greenhouse emission to the atmosphere cause adverse effects to the outdoor environment. Residential developments modify the materials, structure and energy balance in urban climate effects of human economic activities. As an indoor environment is influenced by the outdoor condition, the factors affecting indoor thermal environment are crucial in improving a comfortable and healthy environment in residential building. The microclimatic of a site such as temperature and relative humidity, and wind movement led to the variation of indoor thermal environment in the building.

  12. Indoor environment and pupils' health in primary schools

    DEFF Research Database (Denmark)

    van Dijken, F.; van Bronswijk, J.E.M.H.; Sundell, Jan

    2006-01-01

    the associations between indoor environmental quality in Dutch schools and pupils' health, also taking into account the children's home environment and personal factors. A cross-sectional study was performed in 11 classrooms in 11 different schools in the Netherlands. The study included exposure measurements......Dutch children are legally bound to spend 15% of their time in a school setting. The indoor environment in Dutch primary schools is known to be substandard. However, it is unclear to what extent the health of pupils is affected by the indoor school environment. The paper aims to assess......, building inspections, and a questionnaire survey on pupils' health and domestic exposure. Principal Component Analysis (PCA) and non-parametric tests were performed to assess relationships. None of the schools complied with all indoor environmental quality standards. The importance of both the school...

  13. EVALUATION OF AIR PURIFICATION DEVICES FOR CONTROL OF INDOOR PM

    Science.gov (United States)

    Because people spend most of their time indoors (89%), the indoor environment is a primary determinant of particle exposure. The indoor environment is especially an important determinant for the very young, the very old, and those with underlying cardiopulmonary disease because...

  14. Vitality of plants to live in the indoor environment

    Science.gov (United States)

    Shamsuri, Mohd Mahathir Suhaimi; Leman, A. M.; Hariri, Azian; Idris, Ahmad Fu'ad; Afandi, Azizi

    2017-09-01

    Indoor air quality (IAQ) is generally a public concern because 90% of people spend their time indoor. IAQ must be preserved wisely to guarantee the health of the building occupants. One of the ways to maintain the quality of air is by placing plants in the building. However, all plants come from the outdoor, and the environment is different compared to indoor. Environmental factors such as temperature and light will absolutely affect the growth of the plant. Light and temperature that are too bright or too deem can wither the plants. Nevertheless, certain plant is capable of adapting with different situation after assimilation process has been conducted. This study intends to analyze the capacity of seven selected plants (Anthurium, Dumb Cane, Golden Pothos, Kadaka Fern, Prayer Plant, Spider Plant, and Syngonium) to live in an indoor environment. The vitality of plants is based on photosynthetic level that is measured using leaf - chamber (LI-COR 6400). Two groups of plants were located in indoor and outdoor (indigenous location) setting, and were allowed to assimilate for two months before measurement were carried out. The results for the plant located indoor shows that only Spider Plant cannot perform photosynthesis under 300 lux, where the photosynthetic value remains negative. Meanwhile, other plants such as Anthurium, Dumb Cane, Golden Pothos, Kadaka Fern, Prayer Plant, and Syngonium that were left indoor showed similar 300 lux in which conform the ability of the plants to perform photosynthesis with the value of 0.3, 0.15, 0.35, 0.1, 0.15, and 0.1. In comparison, all of the plants that were stationed indoor and outdoor (except Spider Plant), the light compensation point (LCP) for indoor shows smaller value than the outdoor. This is because all the indoor plants had down - regulated their photosynthesis process by becoming more sensitive to light after their assimilation. From this study, it can be concluded that all plants except Spider Plant is able to live

  15. Personal control over indoor climate and productivity

    NARCIS (Netherlands)

    Boerstra, A.C.; Loomans, M.G.L.C.; Hensen, J.L.M.

    2014-01-01

    A multilayer study was designed to investigate how having or not having control over one’s indoor climate affects work performance in office buildings. The study consisted of 2 stages. The HOPE database (with results from a large study in 64 European office buildings) was reanalyzed on correlations

  16. Scopulariopsis and scopulariopsis-like species from indoor environments

    Directory of Open Access Journals (Sweden)

    J.H.C. Woudenberg

    2017-09-01

    Full Text Available Scopulariopsis-like species are often reported from the indoor environment, as well as from clinical samples. The lack of type isolates and thorough phylogenetic studies in the Microascaceae hampered the correct identification of these isolates. Based on recent phylogenetic studies, which resulted in multiple name changes, the aim is to molecularly identify the Scopulariopsis and scopulariopsis-like species which occur in the indoor environment and give an overview of the current species in these genera and their habitats. Strains from the CBS culture collection were supplemented with almost 80 indoor strains of which the internal transcribed spacer 1 and 2 and intervening 5.8S nrDNA (ITS, beta-tubulin (tub2 and translation elongation factor 1-alpha (tef1 gene regions were sequenced for phylogenetic inference. The multi-gene phylogenies recognise 33 Microascus species and 12 Scopulariopsis species and showed that the recently established genus Fuscoannellis, typified by Scopulariopsis carbonaria, should be synonymized with the genus Yunnania. Seven new Microascus species, four new Scopulariopsis species, and one new Yunnania species, are described, and a new name in Microascus and two new name combinations (one in Microascus, and one in Yunnania are proposed. In the indoor environment 14 Microascus species and three Scopulariopsis species were found. Scopulariopsis brevicaulis (22 indoor isolates and Microascus melanosporus (19 indoor isolates are the most common indoor species, in number of isolates, followed by M. paisii (8 indoor isolates and S. candida (7 indoor isolates. A genus phylogeny based on the ITS, tef1 and the large subunit 28S nrDNA (LSU of the type or representative isolates of all here recognised species is provided depicting all species habitats. No correlation between phylogenetic relationship and habitat preference could be observed. Ten species which are found indoor are also found in relation with human-derived samples. A

  17. A system of UAV application in indoor environment

    DEFF Research Database (Denmark)

    Khosiawan, Yohanes; Nielsen, Izabela Ewa

    2016-01-01

    In recent years, there has been an increased demand in the use of multiple unmanned aerial vehicles (UAVs) in indoor environments such as material handling task in a manufacturing environment and plant/environment monitoring task in a greenhouse. However, there is a lack of work reported on this ......In recent years, there has been an increased demand in the use of multiple unmanned aerial vehicles (UAVs) in indoor environments such as material handling task in a manufacturing environment and plant/environment monitoring task in a greenhouse. However, there is a lack of work reported...... on this topic. This paper presents a detailed study on several UAV systems and UAV scheduling systems. It is followed by a proposed system of UAV application in indoor environment, which comprises components of UAV system addressed in detail; focused on scheduler as the heart of operations. Consequently, system...... architecture of UAV scheduling system is presented and the framework of scheduler component is included. Scheduler component works in a phased manner to provide a systematic abstraction and achieve an efficient computation time. This study serves as a reference guide for UAV application in indoor environment....

  18. Moisture Buffer Effect and its Impact on Indoor Environment

    DEFF Research Database (Denmark)

    Zhang, Mingjie; Qin, Menghao; Chen, Zhi

    2017-01-01

    The moisture buffer effect of building materials may have great influence on indoor hygrothermal environment. In order to characterize the moisture buffering ability of materials, the basic concept of moisture buffer value (MBV) is adopted. Firstly, a theoretical correction factor is introduced...... in this paper. The moisture uptake/release by hygroscopic materials can be calculated with the factor and the basic MBV. Furthermore, the validation of the correction factor is carried out. The impact of moisture buffering on indoor environment is assessed by using numerical simulations. The results show...

  19. Indoor environment in Swedish passive houses

    DEFF Research Database (Denmark)

    Bekö, Gabriel; Langer, Sarka; Bloom, Erica Bloom

    2014-01-01

    The purpose of this study was to evaluate the indoor air quality (IAQ) in newly built low energy houses. Measurements were performed in 22 passive houses and 21 conventional buildings during 2012-2013 and 2013-2014 heating seasons. The measured parameters were temperature, relative humidity......, concentration of CO2, NO2, formaldehyde, volatile organic compounds, and live microbiological flora. Air exchange rates (AER) were determined from the concentration-time profiles of CO2. The median AER was slightly higher in the passive houses than in conventional buildings (0.66 h-1 vs. 0.60 h-1). The median...... concentrations in passive houses and conventional buildings were 9.7 and 11 μg/m3, respectively, for NO2, 12 and 16 μg/m3 for formaldehyde, and 230 and 145 μg/m3 for TVOC. The indoor microbiological flora did not differ, with a few exceptions, from outdoors. The IAQ in the passive buildings was judged...

  20. Lead and cadmium in indoor air and the urban environment

    International Nuclear Information System (INIS)

    Komarnicki, Guenter J.K.

    2005-01-01

    The present study was conducted to find potential terrestrial biomonitors for heavy metals in indoor air in an urban environment. TSP, PM 10 , and PM 2.5 were collected in three retirement facilities in the urban area of Vienna. In addition, particulate matter and soil, vegetation, and isopods (Porcellio scaber L.) were collected in the adjacent garden areas. Aerosols were sampled with a low-volume air sampler. The sampled materials were wet ashed and total lead and cadmium contents were determined. Water-soluble heavy metal concentrations were measured in aqueous extracts from air exposed filters, soil, and vegetation. Lead and cadmium were analyzed by graphite furnace AAS. Lead contents in the vegetation were inferred from water-soluble lead in soils. Lead in isopods generally reflected the contents in vegetation. Cadmium in plants probably derived from soil solutions as well as from atmospheric input. Isopods reflected the total cadmium contents in soils. Particulate matter was dominated by PM 2.5 , both with respect to mass concentrations and to heavy metal contents. The indoor aerosol was found to be influenced by human activity, indoor sources, and outdoor particles. Relationships between indoor airborne heavy metals and the contents in vegetation (lead and cadmium: positive) and isopods (lead: negative) were identified to have the potential for biomonitoring indoor air quality. - Urban vegetation and isopods are potential indicators for indoor aerial heavy metals

  1. Simulation of indoor environment in low energy housing

    DEFF Research Database (Denmark)

    Vagiannis, Georgios; Knudsen, Henrik N.; Toftum, Jørn

    2012-01-01

    was selected and sensitivity analyses were conducted for the importance of occupancy, ventilation, window opening, and heat recovery efficiency. In particular occupancy and venting played significant roles for the indoor environment and energy consumption. It was also shown that with passive measures, but also...

  2. People's clothing behaviour according to external weather and indoor environment

    DEFF Research Database (Denmark)

    De Carli, M.; Olesen, Bjarne W.; Zarrella, A.

    2007-01-01

    In prehistoric times man wore furs of animals to protect himself from the cold. Successively over the centuries clothing has become also a tool to distinguish ourselves in society. Clothing has in addition an important impact on people's perception of the indoor environment. Clothing behaviour ha...

  3. Environment and development of respiratory allergy. II. Indoors.

    Science.gov (United States)

    D'Amato, G; Liccardi, G; D'Amato, M

    1994-12-01

    Even if it is difficult to obtain correct epidemiological evidence, there is a body of evidence which suggests that the frequency of allergic respiratory diseases is increasing. The majority of atopic patients, in particular in childhood and adolescence, develop immunoglobulin E (IgE) antibodies with clinical symptoms to aeroallergens, such as those derived from house dust mites, pollens and pets. Since, in the economically-developed countries individuals spend most of their time indoors (home, school and workplace), indoor pollutants (tobacco smoke etc.) and allergens (house dust mite, cats, etc.) are the most important source of exposure. Indoor allergens are associated with a wide variety of particles in a broad size range, only some of which are microscopically identifiable, culturable, or detectable with existing immunoassay. Evaluation of indoor allergens requires both air and source sampling, and several different analytical techniques. It is likely that the increased prevalence of allergy and asthma may be caused in the indoor environment by the synergistic action of air pollution (in particular derived from tobacco smoking) with allergic sensitization. Passive smoking in infancy has also been involved in the airways allergic sensitization to common aeroallergens.

  4. Breathing thermal manikin for indoor environment assessment: Important characteristics and requirements

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor

    2003-01-01

    Recently breathing thermal manikins have been developed and used for indoor environment measurement, evaluation and optimization as well as validation of Computational Fluid Dynamics (CFD) predictions of airflow around a human body. Advances in the assessment of occupants¿ thermal comfort...... and shape of body segments, control mode, breathing simulation, etc. are discussed and specified in this paper....

  5. Influence of user behavior on unsatisfactory indoor thermal environment

    International Nuclear Information System (INIS)

    Yan, Biao; Long, Enshen; Meng, Xi; Zhang, Yuanze; Hou, Dongqi; Du, Xin

    2014-01-01

    Highlights: • The methodology of numerical simulation of 3D heat-flux visualization is proposed. • A full-scale model of prototype office for each influential factor was set up. • The simulation results were compared with the indoor occupant comfort levels. • The contrast of average temperature increase due to user behavior was presented. - Abstract: In areas of China that have hot summers and cold winters, the overall performance of HVAC systems in the poorly-insulated existing office buildings is generally not satisfactory, especially in extreme weather conditions. The reasons for the unsatisfactory indoor thermal environment were deduced, and to validate the findings, a methodology of numerical simulation for 3D heat-flux visualization was proposed. A full-scale model of a prototype office room was created, with representative working conditions for the characteristics of particular building. The results of the heat-flux visualization and temperature distribution showed that the overall effect was resulted from merged reasons, and that significance ranking of each reason varied when the outside environmental conditions changed. The simulation results were compared with the indoor occupant comfort levels of the volunteers who worked in the target room. Models of possible influential factors such as the outdoor temperature, opening or closing windows, and the effect of window shading devices (WSD) were set up. The influence of user behavior on indoor temperature in opening window, or not using WSD was proven to be significant in causing unfavorable indoor conditions. According to the visualized evaluation and analysis of the various factors, corresponding methods for both improving indoor thermal conditions and saving energy are proposed

  6. Conference particulate matter and indoor environment, I.N.E.R.I.S.; Particulate matter and indoor environment

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-07-01

    Comprehensive characterisation of indoor and outdoor air as well as pollution emission sources Integrated health and environmental risk assessment Scientific and technical basis for airborne pollution management and control Fine and coarse particles. The sources of indoor air pollution are originate separately, are transported separately, are removed from atmosphere by different mechanisms, have different optical properties, have different chemical properties, require different control techniques. for the health effects due to particles, they decrease the lung function, increase respiratory symptoms, increase chronic obstructive pulmonary diseases, increased cardiovascular disease, increased mortality. The different sources contributing to the highest concentrations are: concentrations: tobacco smoking, cooking, vacuuming, dusting and sweeping, heaters, stoves, fireplaces and some other non identified sources. In the future we want more focus on fine and ultra fine particles, investigate source apportionment of particles, better understanding and quantification of exposure, to implement guidelines for particle concentration in indoor air and find better cleaning technologies. (N.C.)

  7. An Evaluation of Antifungal Agents for the Treatment of Fungal Contamination in Indoor Air Environments

    OpenAIRE

    Rogawansamy, Senthaamarai; Gaskin, Sharyn; Taylor, Michael; Pisaniello, Dino

    2015-01-01

    Fungal contamination in indoor environments has been associated with adverse health effects for the inhabitants. Remediation of fungal contamination requires removal of the fungi present and modifying the indoor environment to become less favourable to growth.  This may include treatment of indoor environments with an antifungal agent to prevent future growth. However there are limited published data or advice on chemical agents suitable for indoor fungal remediation. The aim of this study wa...

  8. The airborne metagenome in an indoor urban environment.

    Directory of Open Access Journals (Sweden)

    Susannah G Tringe

    Full Text Available The indoor atmosphere is an ecological unit that impacts on public health. To investigate the composition of organisms in this space, we applied culture-independent approaches to microbes harvested from the air of two densely populated urban buildings, from which we analyzed 80 megabases genomic DNA sequence and 6000 16S rDNA clones. The air microbiota is primarily bacteria, including potential opportunistic pathogens commonly isolated from human-inhabited environments such as hospitals, but none of the data contain matches to virulent pathogens or bioterror agents. Comparison of air samples with each other and nearby environments suggested that the indoor air microbes are not random transients from surrounding outdoor environments, but rather originate from indoor niches. Sequence annotation by gene function revealed specific adaptive capabilities enriched in the air environment, including genes potentially involved in resistance to desiccation and oxidative damage. This baseline index of air microbiota will be valuable for improving designs of surveillance for natural or man-made release of virulent pathogens.

  9. The Airborne Metagenome in an Indoor Urban Environment

    Energy Technology Data Exchange (ETDEWEB)

    Tringe, Susannah; Zhang, Tao; Liu, Xuguo; Yu, Yiting; Lee, Wah Heng; Yap, Jennifer; Yao, Fei; Suan, Sim Tiow; Ing, Seah Keng; Haynes, Matthew; Rohwer, Forest; Wei, Chia Lin; Tan, Patrick; Bristow, James; Rubin, Edward M.; Ruan, Yijun

    2008-02-12

    The indoor atmosphere is an ecological unit that impacts on public health. To investigate the composition of organisms in this space, we applied culture-independent approaches to microbes harvested from the air of two densely populated urban buildings, from which we analyzed 80 megabases genomic DNA sequence and 6000 16S rDNA clones. The air microbiota is primarily bacteria, including potential opportunistic pathogens commonly isolated from human-inhabited environments such as hospitals, but none of the data contain matches to virulent pathogens or bioterror agents. Comparison of air samples with each other and nearby environments suggested that the indoor air microbes are not random transients from surrounding outdoor environments, but rather originate from indoor niches. Sequence annotation by gene function revealed specific adaptive capabilities enriched in the air environment, including genes potentially involved in resistance to desiccation and oxidative damage. This baseline index of air microbiota will be valuable for improving designs of surveillance for natural or man-made release of virulent pathogens.

  10. Risk evaluation and control strategies for indoor radon: a brief discussion

    International Nuclear Information System (INIS)

    Nero, A.V. Jr.

    1994-01-01

    Average risks of death estimated for radon are larger than those for many exposures in the outdoor environment, but similar to some in industrial settings. However, the indoor environment differs in regard to cost, benefit, responsibility, and distribution of risks from the outdoor and occupational settings, where frameworks for setting risk-limiting objectives and strategies have already been developed substantially. This indicates the need to develop a conceptual framework for evaluating risks in the indoor environment, within which the objectives of radon control strategies can be sensibly chosen. Nevertheless, the range of estimated radon risks and of recent radon control strategies suggest near-term elements of any strategy, i.e. accurate and effective public information, as well as reliable monitoring and control capabilities, and a focus on areas where most high residential levels occur. Developing a conceptual framework for evaluating indoor risks will permit the formulation of suitable aims on average indoor exposures and lower exposure situations. (author)

  11. Limitations of ambient air quality standards in evaluating indoor environments

    International Nuclear Information System (INIS)

    Peterson, J.E.

    1992-01-01

    Analysis of the kinds of data used for the derivation of ambient air quality standards (AAQSs) for carbon monoxide and ozone shows that these values are based on the toxicology of the materials and thus are suitable for evaluating potential health effects of indoor environments, especially on the very young, the aged, and the infirm. A similar analysis shows that the AAQSs for suspended particulate matter, nitrogen dioxide, and sulfur dioxide are strictly empirical and that they should not be used for any but their first, intended purpose. The AAQSs for non-methane hydrocarbons are based on photochemical smog production, not injury of any kind, and have no utility for indoor environment evaluation

  12. Radon concentration in indoor occupational environments in Aomori Prefecture, Japan

    International Nuclear Information System (INIS)

    Iyogi, T.; Ueda, S.; Hisamatsu, S.; Kondo, K.; Sakurai, N.; Inaba, J.

    2003-01-01

    The 222 Rn concentrations in indoor workplaces were measured in Aomori Prefecture, Japan, and the results are reported here. This survey was part of a program to measure background natural radiation dose rate in the prefecture where the first Japanese nuclear fuel cycling facilities are now under construction. The survey of the 222 Rn concentrations in indoor workplaces was carried out at 107 locations from 1996 to 1998. The 222 Rn concentrations were measured for approximately one year at each site with passive Rn detectors, which used a polycarbonate film for counting α-rays and could separate concentrations of 222 Rn from 220 Rn. Weeklong measurements of 222 Rn concentration and working level were carried out with active detectors to get the ratio of 222 Rn concentration during working hours to non-working hours as well as equilibrium factors in selected locations. Diurnal variation of 222 Rn concentration depended on building structure, air-conditioning, time of day and day of the week (week days or weekend). The 222 Rn concentration during working hours was generally lower than that in non-working hours. Although the annual average 222 Rn concentration in indoor occupational environments was higher than that in dwellings, radiation dose for Aomori Prefecture residents from Rn in the former was 14% of the total indoor dose by Rn because of the lower concentration in working hours and lower occupancy factor

  13. Radiation exposure of man in the indoor environment

    International Nuclear Information System (INIS)

    Steinhaeusler, F.; Pohl, E.

    1982-01-01

    Indoor exposure of man represents the major component of the dose from the natural radiation environment (NRE). The different sources of the NRE and their complex superposition are discussed. Due to the use of radiologically disadvantageous material in or near the building, radon-rich tap water, specific architectural styles and decreased ventilation rates NRE-levels indoors have been found to even exceed the upper limit for professional exposure. The inadequacy of the existing international regulatory framework and specific local problems resulted in the establishment of national exposure limits. In general, no remedial action is recommended at levels below 50 μR/h for external gamma radiation, 10 mWL for internal radon daughter exposure. Several technical countermeasures reducing indoor gamma dose rates and radon levels have been developed for existing buildings. However, the use of some of the techniques is limited due to low cost-effectiveness or lack of long-term stability. Different techniques in order to achieve low indoor exposures for new buildings and financial aspects associated the application of radiation protection concepts are discussed

  14. Distributed autonomous mapping of indoor environments

    Science.gov (United States)

    Rogers, J.; Paluri, M.; Cunningham, A.; Christensen, H. I.; Michael, N.; Kumar, V.; Ma, J.; Matthies, L.

    2011-06-01

    This paper describes the results of a Joint Experiment performed on behalf of the MAST CTA. The system developed for the Joint Experiment makes use of three robots which work together to explore and map an unknown environment. Each of the robots used in this experiment is equipped with a laser scanner for measuring walls and a camera for locating doorways. Information from both of these types of structures is concurrently incorporated into each robot's local map using a graph based SLAM technique. A Distributed-Data-Fusion algorithm is used to efficiently combine local maps from each robot into a shared global map. Each robot computes a compressed local feature map and transmits it to neighboring robots, which allows each robot to merge its map with the maps of its neighbors. Each robot caches the compressed maps from its neighbors, allowing it to maintain a coherent map with a common frame of reference. The robots utilize an exploration strategy to efficiently cover the unknown environment which allows collaboration on an unreliable communications channel. As each new branching point is discovered by a robot, it broadcasts the information about where this point is along with the robot's path from a known landmark to the other robots. When the next robot reaches a dead-end, new branching points are allocated by auction. In the event of communication interruption, the robot which observed the branching point will eventually explore it; therefore, the exploration is complete in the face of communication failure.

  15. On the history of indoor environment and it's relation to health and wellbeing

    NARCIS (Netherlands)

    Hensen Centnerová, L.

    2018-01-01

    This article describes research and developments in the past that had influence on how people thought and now think about indoor environment. The emphasis is on indoor air quality and thermal comfort.

  16. Digitization and Visualization of Greenhouse Tomato Plants in Indoor Environments

    Directory of Open Access Journals (Sweden)

    Dawei Li

    2015-02-01

    Full Text Available This paper is concerned with the digitization and visualization of potted greenhouse tomato plants in indoor environments. For the digitization, an inexpensive and efficient commercial stereo sensor—a Microsoft Kinect—is used to separate visual information about tomato plants from background. Based on the Kinect, a 4-step approach that can automatically detect and segment stems of tomato plants is proposed, including acquisition and preprocessing of image data, detection of stem segments, removing false detections and automatic segmentation of stem segments. Correctly segmented texture samples including stems and leaves are then stored in a texture database for further usage. Two types of tomato plants—the cherry tomato variety and the ordinary variety are studied in this paper. The stem detection accuracy (under a simulated greenhouse environment for the cherry tomato variety is 98.4% at a true positive rate of 78.0%, whereas the detection accuracy for the ordinary variety is 94.5% at a true positive of 72.5%. In visualization, we combine L-system theory and digitized tomato organ texture data to build realistic 3D virtual tomato plant models that are capable of exhibiting various structures and poses in real time. In particular, we also simulate the growth process on virtual tomato plants by exerting controls on two L-systems via parameters concerning the age and the form of lateral branches. This research may provide useful visual cues for improving intelligent greenhouse control systems and meanwhile may facilitate research on artificial organisms.

  17. Outdoor-indoor air pollution in urban environment: Challenges and opportunity

    Directory of Open Access Journals (Sweden)

    Dennis Y.C. eLeung

    2015-01-01

    Full Text Available With the continual improvement in our quality of life, indoor air quality has become an important area of concern in the 21st century. Indoor air quality is affected by many factors including the type and running conditions of indoor pollution sources, ventilation conditions, as well as indoor activities. Studies revealed that the outdoor environment is also an important factor that cannot be neglected for indoor air quality studies. In this review, the indoor and outdoor air pollution relationships obtained from different studies are discussed in order to identify the key factors affecting the indoor air quality. As climate change is recognized as imposing impacts on the environment, how it affects the indoor air quality and the health impacts to the occupants will be evaluated in this paper. The major challenges and opportunities in indoor/outdoor air pollution studies will be highlighted.

  18. Indoor Radon and Its Decay Products: Concentrations, Causes, and Control Strategies

    Energy Technology Data Exchange (ETDEWEB)

    Nero, A.V.; Gadgil, A.J.; Nazaroff, W.W.; Revzan, K.L.

    1990-01-01

    This report is an introduction to the behavior of radon 222 and its decay products in indoor air. This includes review of basic characteristics of radon and its decay products and of features of the indoor environment itself, all of which factors affect behavior in indoor air. The experimental and theoretical evidence on behavior of radon and its decay products is examined, providing a basis for understanding the influence of geological, structural, and meteorological factors on indoor concentrations, as well as the effectiveness of control techniques. We go on to examine three important issues concerning indoor radon. We thus include (1) an appraisal of the concentration distribution in homes, (2) an examination of the utility and limitations of popular monitoring techniques and protocols, and (3) an assessment of the key elements of strategies for controlling radon levels in homes.

  19. Development of an intelligent indoor environment and energy management system for greenhouses

    International Nuclear Information System (INIS)

    Kolokotsa, D.; Saridakis, G.; Dalamagkidis, K.; Dolianitis, S.; Kaliakatsos, I.

    2010-01-01

    The microclimate control in a greenhouse is a complicated procedure since the variables that influence it are several and dependant on each other. This work is an effort of integrating these variables in a common control methodology through the development of an intelligent environment and energy management system for greenhouses. Two fuzzy logic controllers are developed, embodying the expert knowledge of agriculturists and indoor environment experts. These controllers consist of fuzzy P (Proportional) and PD (Proportional-Derivative) control using desired indoor climatic set-points. The factors being monitored are the greenhouse's indoor illuminance, temperature, relative humidity, CO 2 concentration and the outside temperature. Output actuations include: heating units, motor-controlled windows, motor-controlled shading curtains, artificial lighting, CO 2 enrichment bottles and water fogging valves. These controllers are prototyped in a Matlab environment and simulated using a greenhouse model, which is implemented as a module within the TRNSYS software. The system is tested in a greenhouse located in MAICh (Mediterranean Agronomic Institute of Chania). The overall installation is based on Local Operating Network (LonWorks) protocol.

  20. IEA Project on Indoor Air Quality Design and Control in Low Energy Residential Buildings

    DEFF Research Database (Denmark)

    Rode, Carsten; Abadie, Marc; Qin, Menghao

    2016-01-01

    with heat recovery systems, one of the next focal points to limiting energy consumption for thermally conditioning the indoor environment will be to possibly reducing the ventilation rate, or to make it in a new way demand controlled. However, this must be done such that it has no have adverse effects...... on Indoor Air Quality (IAQ). Annex 68, Indoor Air Quality Design and Control in Low Energy Residential Buildings, is a project under IEA’s Energy Conservation in Buildings and Communities Program (EBC), which will endeavor to investigate how future residential buildings are able to have very high energy...... performance whilst providing comfortable and healthy indoor environments. New paradigms for demand control of ventilation will be investigated, which consider the pollution loads and occupancy in buildings. The thermal and moisture conditions of such will be considered because of interactions between...

  1. Strategies to determine and control the contributions of indoor air pollution to total inhalation exposure (STRATEX)

    DEFF Research Database (Denmark)

    Cochet, C.; Fernandes, E.O.; Jantunen, M.

    ECA-IAQ (European Collaborative Action, Urban Air, Indoor Environment and Human Exposure), 2006. Strategies to determine and control the contributions of indoor air pollution to total inhalation exposure (STRATEX), Report No 25. EUR 22503 EN. Luxembourg: Office for Official Publications...... of the European Communities It is now well established that indoor air pollution contributes significantly to the global burden of disease of the population. Therefore, the knowledge of this contribution is essential in view of risk assessment and management. The ECA STRATEX report collates the respective...... information and describes the strategies to determine population exposure to indoor air pollutants. Its major goal is to emphasise the importance of the contribution of indoor air to total air exposure. Taking this contribution into account is a prerequisite for sound risk assessment of air pollution...

  2. In search of the comfortable indoor environment: A comparison of the utility of objective and subjective indicators of indoor comfort

    Energy Technology Data Exchange (ETDEWEB)

    Fransson, Niklas; Skoog, Jennie [Building Services Engineering, Department of Energy and Environment, Chalmers University of Technology, Gothenburg (Sweden); Vaestfjaell, Daniel [Department of Psychology, Goeteborg University (Sweden)

    2007-05-15

    Today, many procedures for assessing the indoor environment rely on both subjective and objective indicators (e.g. ANSI/ASHRAE 55-2004; ISO 10551). It is however unclear how these two types of measurements are related to perceived comfort. This article aims at assessing the relative utility of subjective (rating scale measures) and objective indicators of perceived comfort of indoor environments. In a hospital setting, physical environmental variables (e.g. temperature, relative humidity and noise level) were simultaneously measured as respondents (both patients and staff) rated their perception of the indoor environment. Regression analyses indicated that the subjective sensory ratings were significantly better than objective indicators at predicting overall rated indoor comfort. These results are discussed in relation to existing measurement procedures and standards. (author)

  3. Anti-logic or common sense that can hinder machine’s energy performance: Energy and comfort control models based on artificial intelligence responding to abnormal indoor environments

    International Nuclear Information System (INIS)

    Ahn, Jonghoon; Cho, Soolyeon

    2017-01-01

    thermal dissatisfaction and energy inefficiency. Comparative analysis describes the decision making model’s effectiveness that it improves thermal comfort levels by about 2.5% for an office building and about 10.2% for residential buildings, and that it reduces annual energy consumption by about 17.4% for an office building and about 25.7% for residential buildings. As a consequence, the integrated energy control model has advantages that it noticeably improves thermal comfort and energy efficiency, and that it properly respond to abnormal and abrupt indoor situations derived from human anti-logic or common sense.

  4. Acquiring 3D indoor environments with variability and repetition

    KAUST Repository

    Kim, Youngmin; Mitra, Niloy J.; Yan, Dongming; Guibas, Leonidas J.

    2012-01-01

    Large-scale acquisition of exterior urban environments is by now a well-established technology, supporting many applications in search, navigation, and commerce. The same is, however, not the case for indoor environments, where access is often restricted and the spaces are cluttered. Further, such environments typically contain a high density of repeated objects (e.g., tables, chairs, monitors, etc.) in regular or non-regular arrangements with significant pose variations and articulations. In this paper, we exploit the special structure of indoor environments to accelerate their 3D acquisition and recognition with a low-end handheld scanner. Our approach runs in two phases: (i) a learning phase wherein we acquire 3D models of frequently occurring objects and capture their variability modes from only a few scans, and (ii) a recognition phase wherein from a single scan of a new area, we identify previously seen objects but in different poses and locations at an average recognition time of 200ms/model. We evaluate the robustness and limits of the proposed recognition system using a range of synthetic and real world scans under challenging settings. © 2012 ACM.

  5. Acquiring 3D indoor environments with variability and repetition

    KAUST Repository

    Kim, Youngmin

    2012-11-01

    Large-scale acquisition of exterior urban environments is by now a well-established technology, supporting many applications in search, navigation, and commerce. The same is, however, not the case for indoor environments, where access is often restricted and the spaces are cluttered. Further, such environments typically contain a high density of repeated objects (e.g., tables, chairs, monitors, etc.) in regular or non-regular arrangements with significant pose variations and articulations. In this paper, we exploit the special structure of indoor environments to accelerate their 3D acquisition and recognition with a low-end handheld scanner. Our approach runs in two phases: (i) a learning phase wherein we acquire 3D models of frequently occurring objects and capture their variability modes from only a few scans, and (ii) a recognition phase wherein from a single scan of a new area, we identify previously seen objects but in different poses and locations at an average recognition time of 200ms/model. We evaluate the robustness and limits of the proposed recognition system using a range of synthetic and real world scans under challenging settings. © 2012 ACM.

  6. Perceived indoor environment and occupants’ comfort in European “Modern” office buildings: The OFFICAIR Study

    NARCIS (Netherlands)

    Sakellaris, I.A.; Saraga, D.E.; Mandin, C.; Roda, C.; Fossati, S.; Kluizenaar, Y. de; Carrer, P.; Dimitroulopoulou, S.; Mihucz, V.G.; Szigeti, T.; Hänninen, O.; Oliveira Fernandes, E. de; Bartzis, J.G.; Bluyssen, P.M.

    2016-01-01

    Indoor environmental conditions (thermal, noise, light, and indoor air quality) may affect workers’ comfort, and consequently their health and well-being, as well as their productivity. This study aimed to assess the relations between perceived indoor environment and occupants’ comfort, and to

  7. Air-Sense: indoor environment monitoring evaluation system based on ZigBee network

    Science.gov (United States)

    Huang, Yang; Hu, Liang; Yang, Disheng; Liu, Hengchang

    2017-08-01

    In the modern life, people spend most of their time indoors. However, indoor environmental quality problems have always been affecting people’s social activities. In general, indoor environmental quality is also related to our indoor activities. Since most of the organic irritants and volatile gases are colorless, odorless and too tiny to be seen, because we have been unconsciously overlooked indoor environment quality. Consequently, our body suffer a great health problem. In this work, we propose Air-Sense system which utilizes the platform of ZigBee Network to collect and detect the real-time indoor environment quality. What’s more, Air-Sense system can also provide data analysis, and visualizing the results of the indoor environment to the user.

  8. Indoor air quality of houses located in the urban environment of Agra, India.

    Science.gov (United States)

    Taneja, Ajay; Saini, Renuka; Masih, Amit

    2008-10-01

    Increased concern over the adverse health effects of air pollution has highlighted the need for air-pollution measurements, especially in urban areas, where many sources of air pollutants are normally monitored outdoors as part of obligations under the National Air Quality Strategies. Very little is known about air pollution indoors. In fact, the largest exposure to health-damaging indoor pollution probably occurs in the developing world, not in households, schools, and offices of developed countries where most research and control efforts have been focused to date. As a result much of the health impacts from air pollution worldwide seem to occur among the poorest and most vulnerable populations. The authors in their earlier studies have confirmed the importance of ambient air in determining the quality of air indoors. In this study an observation of air quality indoors and outdoors of domestic homes located in an urban environment from October 2004 to December 2005 in Agra, north central India, is performed. The purpose of this study was to characterize the indoor/outdoor (I/O) relationship of airborne pollutants and recognize their probable source in all three seasons, that is, winter, summer, and rainy season. Concentrations of SO(2), NO(2), CO(2), Cl(2), H(2)S, NH(3), RSPM, and PAH were monitored simultaneously and I/O ratios were calculated. In order to investigate the effect of seasonality on indoor and ambient air quality, winter to summer and winter to monsoon average ratios were calculated. It is apparent that there is a general pattern of increasing levels from monsoon to summer to winter, and similarly from outdoor to indoor air. Regressions analysis had been done to further investigate the influence of outdoor air-pollutant concentrations on indoor concentrations. The most probable categories of sources for these pollutants have been identified by using principal-component analysis. Indoor air pollution is a complex function of energy housing and

  9. Field study of the indoor environment in a Danish prison

    DEFF Research Database (Denmark)

    Dogbeh, Audrey; Jomaas, Grunde; Bjarløv, Søren Peter

    2015-01-01

    The indoor environment in a Danish prison was evaluated based on measurements made during the summer season of temperature, relative humidity and carbon dioxide, as well as through carefully conducted surveys among the inmates. The temperatures in the cells were high and well beyond common levels...... a compromise must be found to ensure that the building can comply with minimum health and comfort standards. The findings of this study can be used as background for recommendations for renovation of prison buildings.......The indoor environment in a Danish prison was evaluated based on measurements made during the summer season of temperature, relative humidity and carbon dioxide, as well as through carefully conducted surveys among the inmates. The temperatures in the cells were high and well beyond common levels...... in Danish buildings. The mean CO2 concentrations were generally low, but reached high maximum levels up to 5000 ppm. Thirty-one inmates responded to the questionnaire. They spent on average 19 h in the cell per day (range 12–23 h). Sixty-nine percent of the inmates expressed dissatisfaction...

  10. Thoron (220Rn) in the indoor environment and work places

    Science.gov (United States)

    Ramachandran, T. V.; Sahoo, B. K.

    2009-08-01

    Ever since studies on uranium miners established the presence of a positive risk coefficient for the occurrence of lung cancer in miners exposed to elevated levels of 222Rn and its progeny, there was a great upsurge of interest in the measurement of 222Rn in the environment. Subsequently, considerable data is being generated on the levels of 222Rn in the environment across the worlds and is being periodically reported by UNSCEAR reports. In contrast to this, data pertaining to 220Rn in indoors and workplace environment is scaree due to the genral perception that its levels are negligible due to its shorter half life, and subsequently its contribution to the total inhalation dose is ignored, in the presence of other significant sources of natural radiation. This may not be true. Globally many locations have higher levels of natural background radiation due to elevated levels of primordial radio nuclides in the soil and their decay products like radon (222Rn), and thoron (220Rn) in the environment. Of late, technologically enhanced naturally occurring radioactive material has also contributed to the burden of background radiation. It is estimated that inhalation of 222Rn, 220Rn and their short lived progenies contribute more than 54% of the total natural background radiation dose received by the general population. 220Rn problem exists in industries which use thorium nitrate. Including India, lamps using thoriated gas mantles are still being used for indoor and outdoor lighting and by hawkers in rural as well as urban areas. Considering the fact that large amount of thorium nitrate is being handled by these industries, contribution to the inhalation dose of workers from 220Rn gas emanated and build up of the progeny in ambient air may also be quite significant. In this paper current status of 220Rn levels in the indoor environment and workplaces as well as in other industries where large amount of 232Th is being handled is being summarized. Methods of measurement and

  11. Thoron (220Rn) in the indoor environment and work places

    International Nuclear Information System (INIS)

    Ramchandran, T.V.; Sahoo, B.K.

    2009-01-01

    Ever since studies on uranium miners established the presence of a positive risk coefficient for the occurrence of lung cancer in miners exposed to elevated levels of 222 Rn and its progeny, there was a great upsurge of interest in the measurement of 222 Rn in the environment. Subsequently, considerable data is being generated on the levels of 222 Rn in the environment across the worlds and is being periodically reported by UNSCEAR reports. In contrast to this, data pertaining to 220 Rn in indoors and workplace environment is scaree due to the general perception that its levels are negligible due to its shorter half life, and subsequently its contribution to the total inhalation dose is ignored, in the presence of other significant sources of natural radiation. This may not be true. Globally many locations have higher levels of natural background radiation due to elevated levels of primordial radio nuclides in the soil and their decay products like radon ( 222 Rn), and thoron ( 220 Rn) in the environment. Of late, technologically enhanced naturally occurring radioactive material has also contributed to the burden of background radiation. It is estimated that inhalation of 222 Rn, 220 Rn and their short lived progenies contribute more than 54% of the total natural background radiation dose received by the general population. 220 Rn problem exists in industries which use thorium nitrate. Including India, lamps using thoriated gas mantles are still being used for indoor and outdoor lighting and by hawkers in rural as well as urban areas. Considering the fact that large amount of thorium nitrate is being handled by these industries, contribution to the inhalation dose of workers from 220 Rn gas emanated and build up of the progeny in ambient air may also be quite significant. In this paper current status of 220 Rn levels in the indoor environment and workplaces as well as in other industries where large amount of 232 Th is being handled is being summarized. Methods of

  12. Assessment of indoor environment in Paris child day care centers.

    Science.gov (United States)

    Roda, Célina; Barral, Sophie; Ravelomanantsoa, Hanitriniala; Dusséaux, Murielle; Tribout, Martin; Le Moullec, Yvon; Momas, Isabelle

    2011-11-01

    Children are sensitive to indoor environmental pollution. Up until now there has been a lack of data on air quality in child day care centers. The aim of this study is to document the indoor environment quality of Paris child day care centers by repeated measurements, and to compare pollutant levels in child day care centers with levels in Paris dwellings. We selected 28 child day care centers frequented by a random sample of babies who participated in the PARIS birth cohort environmental investigation, and visited the child day care centers for one week twice in one year. Biological contaminants assessed were fungi, endotoxin, dust mite allergens, and chemical pollutants: aldehydes, volatile organic compounds and nitrogen dioxide (NO2). Relative humidity, temperature, and carbon dioxide levels were measured simultaneously. A standardized questionnaire was used to gather information about the buildings and their inhabitants. Airborne endotoxin levels in child day care centers were higher than those found in Paris dwellings. Dust mite allergens in child day care centers were below the threshold level for sensitization in the majority of samples, and in common with dwelling samples. Penicillium and Cladosporium were the most commonly identified genera fungi. The child day care center indoor/outdoor ratio for most chemical pollutants was above unity except for NO2, the levels for NO2 being significantly higher than those measured in homes. Chemical and biological contamination in child day care centers appears to be low, apart from endotoxin and NO2. Failure to take child exposure in child day care centers into account could result in an overestimation of children's exposure to other pollutants. Copyright © 2011 Elsevier Inc. All rights reserved.

  13. Design and Development of a Nearable Wireless System to Control Indoor Air Quality and Indoor Lighting Quality

    Directory of Open Access Journals (Sweden)

    Francesco Salamone

    2017-05-01

    Full Text Available The article describes the results of the project “open source smart lamp” aimed at designing and developing a smart object able to manage and control the indoor environmental quality (IEQ of the built environment. A first version of this smart object, built following a do-it-yourself (DIY approach using a microcontroller, an integrated temperature and relative humidity sensor, and techniques of additive manufacturing, allows the adjustment of the indoor thermal comfort quality (ICQ, by interacting directly with the air conditioner. As is well known, the IEQ is a holistic concept including indoor air quality (IAQ, indoor lighting quality (ILQ and acoustic comfort, besides thermal comfort. The upgrade of the smart lamp bridges the gap of the first version of the device providing the possibility of interaction with the air exchange unit and lighting system in order to get an overview of the potential of a nearable device in the management of the IEQ. The upgraded version was tested in a real office equipped with mechanical ventilation and an air conditioning system. This office was occupied by four workers. The experiment is compared with a baseline scenario and the results show how the application of the nearable device effectively optimizes both IAQ and ILQ.

  14. Plants Clean Air and Water for Indoor Environments

    Science.gov (United States)

    2007-01-01

    Wolverton Environmental Services Inc., founded by longtime government environmental scientist B.C. "Bill" Wolverton, is an environmental consulting firm that gives customers access to the results of his decades of cutting-edge bioremediation research. Findings about how to use plants to improve indoor air quality have been published in dozens of NASA technical papers and in the book, "How to Grow Fresh Air: 50 Houseplants That Purify Your Home or Office." The book has now been translated into 12 languages and has been on the shelves of bookstores for nearly 10 years. A companion book, "Growing Clean Water: Nature's Solution to Water Pollution," explains how plants can clean waste water. Other discoveries include that the more air that is allowed to circulate through the roots of the plants, the more effective they are at cleaning polluted air; and that plants play a psychological role in welfare in that people recover from illness faster in the presence of plants. Wolverton Environmental is also working in partnership with Syracuse University, to engineer systems consisting of modular wicking filters tied into duct work and water supplies, essentially tying plant-based filters into heating, ventilation, and air conditioning (HVAC) systems. Also, the company has recently begun to assess the ability of the EcoPlanter to remove formaldehyde from interior environments. Wolverton Environmental is also in talks with designers of the new Stennis Visitor's Center, who are interested in using its designs for indoor air-quality filters

  15. Air quality inside subway metro indoor environment worldwide: A review.

    Science.gov (United States)

    Xu, Bin; Hao, Jinliang

    2017-10-01

    The air quality in the subway metro indoor microenvironment has been of particular public concern. With specific reference to the growing demand of green transportation and sustainable development, subway metro systems have been rapidly developed worldwide in last decades. The number of metro commuters has continuously increased over recent years in metropolitan cities. In some cities, metro system has become the primary public transportation mode. Although commuters typically spend only 30-40min in metros, the air pollutants emitted from various interior components of metro system as well as air pollutants carried by ventilation supply air are significant sources of harmful air pollutants that could lead to unhealthy human exposure. Commuters' exposure to various air pollutants in metro carriages may cause perceivable health risk as reported by many environmental health studies. This review summarizes significant findings in the literature on air quality inside metro indoor environment, including pollutant concentration levels, chemical species, related sources and health risk assessment. More than 160 relevant studies performed across over 20 countries were carefully reviewed. These comprised more than 2000 individual measurement trips. Particulate matters, aromatic hydrocarbons, carbonyls and airborne bacteria have been identified as the primary air pollutants inside metro system. On this basis, future work could focus on investigating the chronic health risks of exposure to various air pollutants other than PM, and/or further developing advanced air purification unit to improve metro in-station air quality. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Assessment of Thailand indoor set-point impact on energy consumption and environment

    International Nuclear Information System (INIS)

    Yamtraipat, N.; Khedari, J.; Hirunlabh, J.; Kunchornrat, J.

    2006-01-01

    The paper presents an investigation of indoor set-point standard of air-conditioned spaces as a tool to control electrical energy consumption of air-conditioners in Thailand office buildings and to reduce air pollutants. One hundred and forty-seven air-conditioned rooms in 13 buildings nationwide were used as models to analyze the electricity consumption of air-conditioning systems according to their set indoor temperatures, which were below the standard set-point and were accounted into a large scale. Then, the electrical energy and environmental saving potentials in the country were assessed by the assumption that adaptation of indoor set-point temperature is increased up to the standard set-point of 26 o C. It was concluded that the impacts of indoor set-point of air-conditioned rooms, set at 26 o C, on energy saving and on environment are as follows: The overall electricity consumption saving would be 804.60 GWh/year, which would reduce the corresponding GHGs emissions (mainly CO 2 ) from power plant by 579.31x10 3 tons/year

  17. The Quadrotor Dynamic Modeling and Indoor Target Tracking Control Method

    Directory of Open Access Journals (Sweden)

    Dewei Zhang

    2014-01-01

    Full Text Available A reliable nonlinear dynamic model of the quadrotor is presented. The nonlinear dynamic model includes actuator dynamic and aerodynamic effect. Since the rotors run near a constant hovering speed, the dynamic model is simplified at hovering operating point. Based on the simplified nonlinear dynamic model, the PID controllers with feedback linearization and feedforward control are proposed using the backstepping method. These controllers are used to control both the attitude and position of the quadrotor. A fully custom quadrotor is developed to verify the correctness of the dynamic model and control algorithms. The attitude of the quadrotor is measured by inertia measurement unit (IMU. The position of the quadrotor in a GPS-denied environment, especially indoor environment, is estimated from the downward camera and ultrasonic sensor measurements. The validity and effectiveness of the proposed dynamic model and control algorithms are demonstrated by experimental results. It is shown that the vehicle achieves robust vision-based hovering and moving target tracking control.

  18. Consumer exposure to chemicals in indoor environment : A specific focus on chemicals from textile products

    NARCIS (Netherlands)

    Wijnhoven SWP; Kooi MW; te Biesebeek JD; SIR; vgc

    2010-01-01

    Textile products in indoor environment contain a variety of chemicals. Well-known examples are flame retardants, phthalates, formaldehyde and dimethylfumarate. Consumers are potentially exposed to these chemicals since a lot of textile products are present in indoor environment (clothing, curtains,

  19. Scheduling System for Multiple Unmanned Aerial Vehicles in Indoor Environments Using the CSP Approach

    DEFF Research Database (Denmark)

    Park, Youngsoo; Khosiawan, Yohanes; Moon, Ilkyeong

    2016-01-01

    In recent years there has been an increased demand in use of multiple unmanned aerial vehicles (UAVs) for surveillance and material handling tasks in indoor environments. However, only a limited number of studies have been reported on UAV scheduling in an indoor 3D environment. This paper present...

  20. Topological mapping and navigation in indoor environment with invisible barcode

    International Nuclear Information System (INIS)

    Huh, Jin Wook; Chung, Woong Sik; Chung, Wan Kyun

    2006-01-01

    This paper addresses the localization and navigation problem using invisible two dimensional barcodes on the floor. Compared with other methods using natural/artificial landmark, the proposed localization method has great advantages in cost and appearance, since the location of the robot is perfectly known using the barcode information after the mapping is finished. We also propose a navigation algorithm which uses the topological structure. For the topological information, we define nodes and edges which are suitable for indoor navigation, especially for large area having multiple rooms, many walls and many static obstacles. The proposed algorithm also has an advantage that errors occurred in each node are mutually independent and can be compensated exactly after some navigation using barcode. Simulation and experimental results were performed to verify the algorithm in the barcode environment, and the result showed an excellent performance. After mapping, it is also possible to solve the kidnapped case and generate paths using topological information

  1. Multisensor system for toxic gases detection generated on indoor environments

    Science.gov (United States)

    Durán, C. M.; Monsalve, P. A. G.; Mosquera, C. J.

    2016-11-01

    This work describes a wireless multisensory system for different toxic gases detection generated on indoor environments (i.e., Underground coal mines, etc.). The artificial multisensory system proposed in this study was developed through a set of six chemical gas sensors (MQ) of low cost with overlapping sensitivities to detect hazardous gases in the air. A statistical parameter was implemented to the data set and two pattern recognition methods such as Principal Component Analysis (PCA) and Discriminant Function Analysis (DFA) were used for feature selection. The toxic gases categories were classified with a Probabilistic Neural Network (PNN) in order to validate the results previously obtained. The tests were carried out to verify feasibility of the application through a wireless communication model which allowed to monitor and store the information of the sensor signals for the appropriate analysis. The success rate in the measures discrimination was 100%, using an artificial neural network where leave-one-out was used as cross validation method.

  2. Guidelines on Thermal Comfort of Air Conditioned Indoor Environment

    Science.gov (United States)

    Miura, Toyohiko

    The thermal comfort of air conditioned indoor environment for workers depended, of course, on metabolic rate of work, race, sex, age, clothing, climate of the district and state of acclimatization. The attention of the author was directed to the seasonal variation and the sexual difference of comfortable temperature and a survey through a year was conducted on the thermal comfort, and health conditions of workers engaged in light work in a precision machine factory, in some office workers. Besides, a series of experiments were conducted for purpose of determinning the optimum temperature of cooling in summer time in relation to the outdoor temperature. It seemed that many of workers at present would prefer somewhat higher temperature than those before the World War II. Forty years ago the average homes and offices were not so well heated as today, and clothing worn on the average was considerably heavier.

  3. Measurements of indoor thermal environment and energy analysis in a large space building in typical seasons

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Chen; Zou, Zhijun; Li, Meiling; Wang, Xin; Huang, Wugang; Yang, Jiangang [University of Shanghai for Science and Technology, Shanghai (China); Li, Wei; Xiao, Xueqin [Shanghai International Gymnastics Stadium, Shanghai (China)

    2007-05-15

    Shanghai International Gymnastics Stadium is the selected object for site-measurement. The site-measurements have been carried out during summer, winter, and the transitional seasons. Their indoor thermal environments were controlled by continuous air-conditioning, intermittent air-conditioning and natural ventilation, respectively. The site-measurement includes outdoor environment (the weather conditions and peripheral hallway), indoor air temperature distribution (the occupant zone temperature, radial temperature near upper openings and the vertical temperature distributions, etc.), and the heat balance of air-conditioning system, etc. It is found that temperature stratification in winter with air-conditioning is most obvious. The maximum difference of vertical temperature is 15{sup o}C in winter. The second largest one is 12{sup o}C in summer, and less than 2{sup o}C in the transitional season. The results of measurements indicate that it is different in the characteristics on energy saving of upper openings during the different seasons. With heat balance measurements, it is discovered that the roof load and ventilated and infiltrated load account for larger percentages in terms of cooling and heating load. In this paper, many discussions on the results of site measurements show some characteristics and regulations of indoor thermal environment in large space building. (author)

  4. Humidification and perceived indoor air quality in the office environment.

    Science.gov (United States)

    Reinikainen, L M; Aunela-Tapola, L; Jaakkola, J J

    1997-01-01

    OBJECTIVE: To evaluate the effect of humidification on the odour, acceptability, and stuffiness of indoor air. METHODS: In a six period cross over trial at the Pasila Office Center, Helsinki, the air of two wings of the building in turn were ventilated with air of 30%-40% humidity. A third wing served as a non-humidified control area. The quality of indoor air was assessed weekly by a panel containing 18 to 23 members. The intraindividual differences in the ratings for odour, stuffiness, and acceptability between humidified and non-humidified wings were used to assess the effect of humidification. The roles of sex, current smoking, and age as potential effect modifiers were assessed by comparing the mean intraindividual differences in ratings between the groups. RESULTS: Humidified air was found to be more odorous and stuffy (paired t test P = 0.0001) and less acceptable than the non-humidified air (McNemar's test P humidification decreases the perceived air quality. This effect is strongest in women and young subjects. PMID:9196454

  5. Indoor air in school environment and the impact on children’s health

    International Nuclear Information System (INIS)

    Krajcova, D.; Vondrova, D.; Hirosova, K.; Sevcikova, L.

    2014-01-01

    More attention is paid to assessing the quality of not only outdoor but also indoor air. Since children spend large part of their time at schools, several studies are aimed at indoor air monitoring in schools. These studies confirmed association between poor quality of indoor environment and the incidence of asthma and other respiratory diseases of children. The most serious indoor air pollutants includes dust particles, inorganic and volatile organic compounds, components of tobacco smoke, mold and dust mites. Providing healthy school environment should be one of the basic methods to protect and support physical and mental health and development of children. (author)

  6. Effects of Inhalation of Emissions from Cedar Timber on Psychological and Physiological Factors in an Indoor Environment

    Directory of Open Access Journals (Sweden)

    Kenichi Azuma

    2016-12-01

    Full Text Available Components extracted from cedar timber have been reported to have stress-reducing effects in humans. If the positive effects of cedar timber in indoor environments are scientifically proven, an indoor environment that utilizes cedar timber may contribute to the improvement or promotion of well-being in humans. In this study, we evaluated the effects of inhaling emissions of volatile constituents from cedar timber (Cryptomeria japonica on the psychological and physiological factors in indoor environments. A case-control study with a crossover design was conducted with 10 subjects occupying two rooms that were controlled for interior materials, indoor climate, and room size. Cedrol and β-eudesmol were specifically detected in the case room. However, no significant differences were observed in psychological and physiological factors. There was a significant loss in vigor in the control group from the time before entering the room to the time after leaving the room; however, this loss in vigor was not seen in the case group. Temperature conditions were higher than the indoor environmental standard in Japan but similar in the two groups. Our results showed a minor positive change in vigor among participants exposed to cedar timber for a short term. Inhalation of emissions of volatile constituents from cedar timber may have positive effects in humans; however, further research on their efficacy is needed.

  7. An Autonomous Mobile Robotic System for Surveillance of Indoor Environments

    Directory of Open Access Journals (Sweden)

    Donato Di Paola

    2010-02-01

    Full Text Available The development of intelligent surveillance systems is an active research area. In this context, mobile and multi-functional robots are generally adopted as means to reduce the environment structuring and the number of devices needed to cover a given area. Nevertheless, the number of different sensors mounted on the robot, and the number of complex tasks related to exploration, monitoring, and surveillance make the design of the overall system extremely challenging. In this paper, we present our autonomous mobile robot for surveillance of indoor environments. We propose a system able to handle autonomously general-purpose tasks and complex surveillance issues simultaneously. It is shown that the proposed robotic surveillance scheme successfully addresses a number of basic problems related to environment mapping, localization and autonomous navigation, as well as surveillance tasks, like scene processing to detect abandoned or removed objects and people detection and following. The feasibility of the approach is demonstrated through experimental tests using a multisensor platform equipped with a monocular camera, a laser scanner, and an RFID device. Real world applications of the proposed system include surveillance of wide areas (e.g. airports and museums and buildings, and monitoring of safety equipment.

  8. An Autonomous Mobile Robotic System for Surveillance of Indoor Environments

    Directory of Open Access Journals (Sweden)

    Donato Di Paola

    2010-03-01

    Full Text Available The development of intelligent surveillance systems is an active research area. In this context, mobile and multi-functional robots are generally adopted as means to reduce the environment structuring and the number of devices needed to cover a given area. Nevertheless, the number of different sensors mounted on the robot, and the number of complex tasks related to exploration, monitoring, and surveillance make the design of the overall system extremely challenging. In this paper, we present our autonomous mobile robot for surveillance of indoor environments. We propose a system able to handle autonomously general-purpose tasks and complex surveillance issues simultaneously. It is shown that the proposed robotic surveillance scheme successfully addresses a number of basic problems related to environment mapping, localization and autonomous navigation, as well as surveillance tasks, like scene processing to detect abandoned or removed objects and people detection and following. The feasibility of the approach is demonstrated through experimental tests using a multisensor platform equipped with a monocular camera, a laser scanner, and an RFID device. Real world applications of the proposed system include surveillance of wide areas (e.g. airports and museums and buildings, and monitoring of safety equipment.

  9. Investigation on Moisture and Indoor Environment in Eight Danish Houses

    DEFF Research Database (Denmark)

    Jensen, Kasper Risgaard; Jensen, Rasmus Lund; Nørgaard, Jesper

    2011-01-01

    then need to be ventilated actively either by natural or mechanical ventilation. Increased focus on energy reduction together with requirements for e.g. thermal comfort indoors may lead to reduced indoor air quality and moisture problems which in turn may cause mould problems. This paper describes...... an investigation of the indoor air quality, relative humidity and air change rate in eight Danish houses. The houses were selected as they are all having recurrent problems with condensation on the windows. The houses were built between 1930 and 2007. Some of them have been only slightly renovated where others......, to indoor air quality in terms of CO2 concentration, and to the use of the house in terms of the level of the relative humidity and indoor moisture excess. Furthermore, the moisture production in the houses was estimated and compared to values provided in the literature. A better indoor air quality...

  10. The effect of the indoor environment on the fate of organic chemicals in the urban landscape.

    Science.gov (United States)

    Cousins, Anna Palm

    2012-11-01

    To assess the effect of the indoor environment on the urban fate of organic chemicals, an 8-compartment indoor-inclusive steady state multimedia chemical fate model was developed. The model includes typical urban compartments (air, soil, water, sediment, and urban film) and a novel module representing a generic indoor environment. The model was parameterized to the municipality of Stockholm, Sweden and applied to four organic chemicals with different physical-chemical characteristics and use patterns: formaldehyde, 2,4,6-tribromophenol, di-ethylhexylphthalate and decabromodiphenyl ether. The results show that emissions to indoor air may increase the steady state mass and residence time in the urban environment by a factor of 1.1 to 22 for the four chemicals, compared to if emissions are assigned to outdoor air. This is due to the nested nature of the indoor environment, which creates a physical barrier that prevents chemicals from leaving the urban system with outflowing air. For DEHP and BDE 209, the additional partitioning to indoor surfaces results in a greater importance of the indoor removal pathways from surfaces. The outdoor environmental concentrations of these chemicals are predicted to be lower if emitted to indoor air than if emitted to outdoor air because of the additional indoor removal pathways of dust and indoor film, leading to loss of chemical from the system. For formaldehyde and 2,4,6-TBP outdoor environmental concentrations are not affected by whether the release occurs indoors or outdoors because of the limited partitioning to indoor surfaces. A sensitivity analysis revealed that there appears to be a relationship between logK(OA) and the impact of the ventilation rate on the urban fate of organic chemicals. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. Waste-based materials; capability, application and impact on indoor environment – literature review

    DEFF Research Database (Denmark)

    Krejcirikova, Barbora; Rode, Carsten; Kolarik, Jakub

    2014-01-01

    This paper reviews and discusses various sustainable materials utilizing waste products with the focus on their properties having an impact on the indoor environmental conditions and indoor air quality (IAQ). Materials included in the review are selected considering the following aspects......: sustainability, cradle to cradle perspective, application, their impact on indoor environment and human well-being. The attempt of the paper is to cover a wide spectrum of information so to provide better understanding of waste utilization in construction industry....

  12. Radon and aldehyde concentrations in the indoor environment. Final report

    International Nuclear Information System (INIS)

    Moschandreas, D.J.; Rector, H.E.

    1981-04-01

    Findings regarding indoor air contaminants in the energy-efficient residence (EER) in Mt. Airy, Maryland are reported. The objectives of the study were to collect and analyze relevant air quality samples (specifically radon and aldehydes), characterize the indoor air quality with respect to radon and aldehydes, and develop relationships between air infiltration rates and contaminant levels. One-fifth of the measured formaldehyde concentrations were in the range that may cause health concerns. Although indoor temperature and relative humidity affect indoor HCHO concentration, the elevated formaldehyde concentrations were measured under very low air infiltration rates. The data show that ventilation of the indoor air space is somewhat effective in reducing high HCHO concentrations. The operation of the heat exchanger led to an increase of the air infiltration rate which in turn resulted in substantial reduction of formaldehyde concentrations. A considerable number of the collected samples of indoor air displayed radon concentrations at levels higher than 1.0 to 4.0 nCim -3 (assuming an equilibrium factor of 0.5, these radon levels would correspond to working levels above the health guidelines suggested by the US EPA for homes in Florida built on land reclaimed from phosphate mining). As in the case of indoor formaldehyde concentrations, elevated indoor concentrations are substantially reduced when the infiltration rate is increased. The data base shows that the use of the air to air heat exchanger leads to reduction of indoor radon concentration by increasing the residential ventilation rate

  13. Combining a survey approach and energy and indoor environment auditing in historic buildings

    DEFF Research Database (Denmark)

    Rohdin, Patrik; Dalewski, Mariusz; Moshfegh, Bahram

    2016-01-01

    Purpose – This paper presents an approach where a survey study is combined with energy and indoor environment auditing in the built environment. The combination of methods presented in this paper is one way to obtain a wider perspective on the indoor environment and energy use and also let...... this research project. Design/methodology/approach – A combination of energy and indoor environment auditing and standardized occupant surveys. Findings – The main findings in the paper are related to the good agreement between results from standardized occupant surveys and physical measurements...

  14. Occurrence, dynamics and reactions of organic pollutants in the indoor environment

    Energy Technology Data Exchange (ETDEWEB)

    Salthammer, Tunga [Material Analysis and Indoor Chemistry, Fraunhofer Wilhelm-Klauditz Institut (WKI), Braunschweig (Germany); Bahadir, Muefit [Institut fuer Oekologische Chemie und Abfallanalytik, Technische Universitaet Braunschweig, Braunschweig (Germany)

    2009-06-15

    The indoor environment is a multidisciplinary scientific field involving chemistry, physics, biology, health sciences, architecture, building sciences and civil engineering. The need for reliable assessment of human exposure to indoor pollutants is attracting increasing attention. This, however, requires a detailed understanding of the relevant compounds, their sources, physical and chemical properties, dynamics, reactions, their distribution among the gas phase, airborne particles and settled dust as well as the availability of modern measurement techniques. Building products, furnishings and other indoor materials often emit volatile and semi-volatile organic compounds. With respect to a healthy indoor environment, only low emitting products, which do not influence indoor air quality in a negative way, should be used in a building. Therefore, materials and products for indoor use need to be evaluated for their chemical emissions. This is routinely done in test chambers and cells. Many studies have shown that the types of sources in occupational and residential indoor environments, the spectrum of emitting compounds and the duration of emission cover a wide range. The demand for standardized test methods under laboratory conditions has resulted in several guidelines for determination of emission rates. Furthermore, it has now been recognized that both primary and secondary emissions may affect indoor air quality. The problem may become more dominant when components of different materials can react with each other or when catalytic materials are applied. Such products derived from indoor related reactions may have a negative impact on indoor air quality due to their low odor threshold, health related properties or the formation of ultrafine particles. Several factors can influence the emission characteristics and numerous investigations have shown that indoor chemistry is of particular importance for the indoor related characterization of building product emissions

  15. Indoor thermal environment of bedroom during sleep in Malaysia

    Science.gov (United States)

    Tsuzuki, Kazuyo; Mori, Ikue

    2017-10-01

    This study was conducted to investigate the indoor thermal environment and sleep of occupants in bedrooms where air conditioners (ACs) are preferentially installed. Field measurements and questionnaires were conducted for 22 houses, with a total of 28 occupants, located in the suburbs of Kuala Lumpur. The participants were requested to wear a wrist actigraphy on the non-dominant hand for three consecutive days, except while bathing or washing hands in order to evaluate sleep by the activity of the actigraphy. The average air temperatures in the bedrooms were 22.6-28.9 °C and 28.1-32.2 °C with and without AC, respectively. The observed lowest air temperature was below 21 °C in a bedroom with AC. Such low air temperatures are not considered appropriate in terms of energy consumption and the occupants' physiological condition during sleep. The wind velocity of fresh air coming through the open window was found as well as when the use of a fan. From the relations among the factors of thermal environment, increased wind velocity seems to compensate for increased air temperature and increased relative humidity. The sleep efficiency index (SEI) looks decreased in accordance with increased air temperature, increased air velocity, and increased relative humidity. However, no statistical significances were found in those relationships. New effective temperature (SET*) was calculated from measured thermal factors and relation was examined with SEI.

  16. P-marking of indoor environment and energy use - Considerations prior to certification of energy use

    Energy Technology Data Exchange (ETDEWEB)

    Wahlstroem, Aasa

    2008-02-15

    SP Technical Research Institute of Sweden's P-marking quality assurance scheme for buildings, products, services etc., now includes P-marking of the indoor environment and energy use performance of buildings. The rules for the system, which cover new buildings, renovation and existing buildings, are set out in SP's Certification Rules no. SPCR 114E, specifying requirements in respect of both energy use and indoor environment management. Over the last ten years, SP has carried out considerable work in the field of the indoor environment, resulting in the development of a quality assurance system concentrating on achieving a high-quality indoor environment. This quality assurance system has been successfully applied to schools, offices and dwellings. However, the performance of a building is determined not only by a good indoor environment, but also by low impact on the external environment as a result of energy use in the building. In some cases, concentrating on either good indoor environment or energy efficiency may result in an adverse effect on the other aspect, and so the quality assurance system for indoor environments been extended with a section dealing with energy use. This document is a handbook for inspection of documentation concerning quality assurance of energy use (primary energy analysis, determination of energy targets, energy management systems etc.). It can also be helpful for the organisation that is applying for P-marking when drawing up checklists. The document concentrates on requirements for approved certification of energy use in connection with P-marking of indoor environments and energy use in existing buildings: it does not cover requirements for certification of indoor environments. It starts by describing targeting, aims and requirements for P-marking of energy use, followed by presentation of some examples of inspections of collected documentation

  17. Comparative Analysis between Conventional PI and Fuzzy LogicPI Controllers for Indoor Benzene Concentrations

    Directory of Open Access Journals (Sweden)

    Nun Pitalúa-Díaz

    2015-05-01

    Full Text Available Exposure to hazardous concentrations of volatile organic compounds indoors in small workshops could affect the health of workers, resulting in respirative diseases, severe intoxication or even cancer. Controlling the concentration of volatile organic compounds is required to prevent harmful conditions for workers in indoor environments. In this document, PI and fuzzy PI controllers were used to reduce hazardous indoor air benzene concentrations in small workplaces. The workshop is represented by means of a well-mixed room model. From the knowledge obtained from the model, PI and fuzzy PI controllers were designed and their performances were compared. Both controllers were able to maintain the benzene concentration within secure levels for the workers. The fuzzy PI controller performed more efficiently than the PI controller. Both approaches could be expanded to control multiple extractor fans in order to reduce the air pollution in a shorter time. The results from the comparative analysis showed that implementing a fuzzy logic PI controller is promising for assuring indoor air quality in this kind of hazardous work environment.

  18. Towards support for collaborative navigation in complex indoor environments

    NARCIS (Netherlands)

    Bouwer, A.; Nack, F.; Evers, V.

    2011-01-01

    In this paper we present first results of an observation study on indoor navigation behaviour of visitors at a large public fair. As an outcome we present a number of requirements for mobile indoor navigation systems that support collaborative destination and path finding tasks.

  19. The effect of the indoor environment on the fate of organic chemicals in the urban landscape

    Energy Technology Data Exchange (ETDEWEB)

    Cousins, Anna Palm, E-mail: anna.cousins@ivl.se

    2012-11-01

    To assess the effect of the indoor environment on the urban fate of organic chemicals, an 8-compartment indoor-inclusive steady state multimedia chemical fate model was developed. The model includes typical urban compartments (air, soil, water, sediment, and urban film) and a novel module representing a generic indoor environment. The model was parameterized to the municipality of Stockholm, Sweden and applied to four organic chemicals with different physical-chemical characteristics and use patterns: formaldehyde, 2,4,6-tribromophenol, di-ethylhexylphthalate and decabromodiphenyl ether. The results show that emissions to indoor air may increase the steady state mass and residence time in the urban environment by a factor of 1.1 to 22 for the four chemicals, compared to if emissions are assigned to outdoor air. This is due to the nested nature of the indoor environment, which creates a physical barrier that prevents chemicals from leaving the urban system with outflowing air. For DEHP and BDE 209, the additional partitioning to indoor surfaces results in a greater importance of the indoor removal pathways from surfaces. The outdoor environmental concentrations of these chemicals are predicted to be lower if emitted to indoor air than if emitted to outdoor air because of the additional indoor removal pathways of dust and indoor film, leading to loss of chemical from the system. For formaldehyde and 2,4,6-TBP outdoor environmental concentrations are not affected by whether the release occurs indoors or outdoors because of the limited partitioning to indoor surfaces. A sensitivity analysis revealed that there appears to be a relationship between logK{sub OA} and the impact of the ventilation rate on the urban fate of organic chemicals. -- Highlights: Black-Right-Pointing-Pointer A novel indoor-inclusive multimedia urban fate model is developed and applied. Black-Right-Pointing-Pointer Emissions indoors may increase the urban chemical residence time. Black

  20. The effect of the indoor environment on the fate of organic chemicals in the urban landscape

    International Nuclear Information System (INIS)

    Cousins, Anna Palm

    2012-01-01

    To assess the effect of the indoor environment on the urban fate of organic chemicals, an 8-compartment indoor-inclusive steady state multimedia chemical fate model was developed. The model includes typical urban compartments (air, soil, water, sediment, and urban film) and a novel module representing a generic indoor environment. The model was parameterized to the municipality of Stockholm, Sweden and applied to four organic chemicals with different physical–chemical characteristics and use patterns: formaldehyde, 2,4,6-tribromophenol, di-ethylhexylphthalate and decabromodiphenyl ether. The results show that emissions to indoor air may increase the steady state mass and residence time in the urban environment by a factor of 1.1 to 22 for the four chemicals, compared to if emissions are assigned to outdoor air. This is due to the nested nature of the indoor environment, which creates a physical barrier that prevents chemicals from leaving the urban system with outflowing air. For DEHP and BDE 209, the additional partitioning to indoor surfaces results in a greater importance of the indoor removal pathways from surfaces. The outdoor environmental concentrations of these chemicals are predicted to be lower if emitted to indoor air than if emitted to outdoor air because of the additional indoor removal pathways of dust and indoor film, leading to loss of chemical from the system. For formaldehyde and 2,4,6-TBP outdoor environmental concentrations are not affected by whether the release occurs indoors or outdoors because of the limited partitioning to indoor surfaces. A sensitivity analysis revealed that there appears to be a relationship between logK OA and the impact of the ventilation rate on the urban fate of organic chemicals. -- Highlights: ► A novel indoor-inclusive multimedia urban fate model is developed and applied. ► Emissions indoors may increase the urban chemical residence time. ► Indoor removal from surfaces constitutes an additional loss process

  1. Evaluating Wi-Fi indoor positioning approaches in a real world environment

    OpenAIRE

    Hantoush, Raafat

    2016-01-01

    Global positioning system(GPS) does not provide generally a good positioning performance in an indoor location because of many reasons (Henniges, 2012). On the other hand, other alternatives such as the WI-FI technology has become recently in a popular use to provide indoor localization. And that is due to many reasons, such as the wide spread of WI-FI infrastructure in the indoor environments and the low cost of this technology. This study attempts to evaluate different WI-FI indoor position...

  2. Natural indoor gamma background in Coonoor environment of South India

    International Nuclear Information System (INIS)

    Sivakumar, R.; Selvasekarapandian, S.; Mugunthamanikand, N.; Raghunath, V.M.

    2002-01-01

    Indoor natural radiation dose existing in dwellings of Coonoor have been estimated using thermoluminescent dosimeters. TLDs are displayed in indoors and are replaced after three-month period. The seasonal averages of the dose rate and the annual effective dose equivalent are calculated from the measured results. Geographical and seasonal variations as well as the differences between indoor to outdoor dose rates have also been studied. Very good correlation exists between the indoor dose rates measured by LTD and environmental radiation dosimeter with correlation coefficient of 0.91. The annual effective dose equivalent to the Coonoor population due to indoor gamma radiation was estimated to be 970 μSv/y for the period of 1997-1998. (author)

  3. Inter-comparison of air pollutant concentrations in different indoor environments in Hong Kong

    Science.gov (United States)

    Lee, Shun-Cheng; Guo, Hai; Li, Wai-Ming; Chan, Lo-Yin

    Indoor air quality in selected indoor environments in Hong Kong such as homes, offices, schools, shopping malls and restaurants were investigated. Average CO 2 levels and total bacteria counts in air-conditioned classrooms, shopping malls and restaurants were comparatively higher than those measured in occupied offices and homes. Elevated CO 2 levels exceeding 1000 ppm and total bacteria counts resulted from high occupancy combined with inadequate ventilation. Average PM 10 levels were usually higher indoors than outdoors in homes, shopping malls and restaurants. The highest indoor PM 10 levels were observed at investigated restaurants due to the presence of cigarette smoking and extensive use of gas stoves for cooking. The restaurants and shopping malls investigated had higher formaldehyde levels than other indoor environments when building material, smoking and internal renovation work were present. Volatile organic compounds (VOCs) in both indoor and outdoor environments mainly resulted from vehicle exhaust emissions. It was observed that interior decoration work and the use of industrial solvents in an indoor environment could significantly increase the indoor levels of VOCs.

  4. Parametric studies and evaluations of indoor thermal environment in wet season using a field survey and PMV-PPD method

    Energy Technology Data Exchange (ETDEWEB)

    Wei, Shengxian [College of Physics and Electric Engineering, Qujing Normal University, Qujing 655011 (China); Key Laboratory of Advanced Technique and Preparation for Renewable Energy Materials, Ministry of Education, Yunnan Normal University, Kunming 650092 (China); Li, Ming [Key Laboratory of Advanced Technique and Preparation for Renewable Energy Materials, Ministry of Education, Yunnan Normal University, Kunming 650092 (China); Lin, Wenxian [Key Laboratory of Advanced Technique and Preparation for Renewable Energy Materials, Ministry of Education, Yunnan Normal University, Kunming 650092 (China); School of Engineering, James Cook University, Townsville, QLD 4811 (Australia); Sun, Yanlin [College of Physics and Electric Engineering, Qujing Normal University, Qujing 655011 (China)

    2010-06-15

    Fanger's PMV-PPD is the most famous thermal sensation indices but it is too complex to be applied in practice. To obtain simple and applicable correlations, taking Qujing of Yunnan province, China, as example, a wet season (six-month) field measurement was conducted in a naturally ventilated residential room. Based on collected data, PMV indices were calculated by using Newton's iterative method. It is shown that the PMV values approximately vary from -1.0 to +1.0 and the indoor thermal environment is basically comfortable. Relationships of the parameters (indoor and outdoor air temperatures, mean radiant temperature, PMV and PPD) and indoor air temperature gradients (vertical and horizontal) were also studied by means of the linear regression and the quadratic polynomial fit techniques. Numerous correlations with high relativities have been developed. Moreover, the vertical and horizontal air temperature gradients range from 0.1 K/m to 0.85 K/m and from -0.208 K/m to 0.063 K/m in wet season. It is convenient to use these results to evaluate and assess the indoor thermal environment under similar climatic conditions. The results of this work enrich and develop the basic theory of the indoor thermal environment design and control. (author)

  5. Control of radon and its progeny concentration in indoor atmosphere

    International Nuclear Information System (INIS)

    Ramachandran, T.V.; Subbaramu, M.C.

    1986-01-01

    Exposure to radon daughter concentration in indoor atmosphere can result in a significant risk to the general public. There are two generally used methods for the control of radon and progeny concentration in the indoor atmosphere, namely restriction of radon entry and reduction of indoor radon and its progeny concentration by ventilation or by air cleaning. Predominant radon entry process in most of the dwellings appears to be by pressure driven flow of soil gas through cracks or other openings in the basement slab or subfloors. Sealing these openings or ventilation of the subslab or subfloor space are the methods for reducing the radon entry rates. Indoor radon concentration can also be reduced by increasing the ventilation and by using charcoal filters for the removal of radon gas in indoor air by absorption. Concentration of radon progeny, which are responsible for most of the health risks associatd with radon exposure can also be controlled by the use of electrostatic or mechanical filters. This study describes briefly the above control strategies used for reducing the inhalation doses to persons in dwellings. (author). 9 refs., 2 tables

  6. Intelligent navigation and accurate positioning of an assist robot in indoor environments

    Science.gov (United States)

    Hua, Bin; Rama, Endri; Capi, Genci; Jindai, Mitsuru; Tsuri, Yosuke

    2017-12-01

    Intact robot's navigation and accurate positioning in indoor environments are still challenging tasks. Especially in robot applications, assisting disabled and/or elderly people in museums/art gallery environments. In this paper, we present a human-like navigation method, where the neural networks control the wheelchair robot to reach the goal location safely, by imitating the supervisor's motions, and positioning in the intended location. In a museum similar environment, the mobile robot starts navigation from various positions, and uses a low-cost camera to track the target picture, and a laser range finder to make a safe navigation. Results show that the neural controller with the Conjugate Gradient Backpropagation training algorithm gives a robust response to guide the mobile robot accurately to the goal position.

  7. Can the interaction between occupant behaviour and the indoor environment in residences be influenced?

    DEFF Research Database (Denmark)

    Andersen, Søren

    study and four field studies that focused on how to affect occupants’ control of the indoor environment. The four studies used measurements of the temperature, relative humidity, and CO2 concentration in 84 rental apartments. The conclusions made in the thesis are derived from an analysis...... the findings of earlier studies, that feedback should be disseminated as frequently as possible. The studies demonstrated the importance of barrier-free access to real-time feedback, as even a little barrier caused the occupants to ignore the feedback. It is recommended that feedback should be disseminated...

  8. Analysis on Energy Consumption and Indoor Environment in Kunming, China

    Directory of Open Access Journals (Sweden)

    Tianchi Hu

    2012-10-01

    Full Text Available The purposes of this study are to investigate and analyze the actual conditions of the urban residential energy consumption, and hence to ascertain what will be the important factors that influence the annual energy consumption in Kunming, which has a mild climate. The questionnaire surveys reveal building characteristics, housing appliances, household characteristics, indoor thermal environment and aspects of life style, during winter and summer seasons. The questionnaire analyses show that only 5% of the investigated households have air conditioning, and 12% have heating appliances. Most households use solar energy as a water heater energy source because the sunshine hours in Kunming are long. The energy consumption analyses show that the average annual energy consumption of households in Kunming reached 12.2 GJ, and cooking accounted for 5.3 GJ, which is the largest part. Most of the time in summer, the outdoor temperature is lower than living room and bedroom temperatures; thus, natural ventilation is a useful cooling method for households in Kunming. The absolute humidity in summer is about 11 g/kg, while in winter it is about 5 g/kg. The influence factor analyses show that building construction year, water heater type and annual income are important influential factors on annual energy consumption.

  9. Augmented reality aided operation and maintenance system for indoor environments

    International Nuclear Information System (INIS)

    Tamura, Yuichi; Umetani, Tomohiro; Kubo, Shin

    2013-01-01

    This paper proposes an Augmented Reality (AR) system to assist operation and maintenance tasks in an indoor environment, such as a nuclear fusion reactor and its building. AR is a technology that enhances real information by adding 3D virtual objects, images, sounds, or movies via a web camera. The AR system often uses “markers” such as QR code to detect the place where the virtual content should appear. However, these markers are unnatural and they can disturb the scenery. We propose an AR system that can detect natural markers, which provides AR content via a network. This system stores the information related to markers and virtual objects on a server. A device connected to this system automatically downloads this content so that the user can watch the AR content via a web camera. We add a real-time numerical simulation function that allows us to simulate physical phenomena by touching AR contents. It also enables us to observe simulation results by downloading a movie of numerical simulation results from the simulation server. Overall, this system allows us to watch the same content with multiple devices and to simulate physical phenomena using various parameters. (author)

  10. Loose fusion based on SLAM and IMU for indoor environment

    Science.gov (United States)

    Zhu, Haijiang; Wang, Zhicheng; Zhou, Jinglin; Wang, Xuejing

    2018-04-01

    The simultaneous localization and mapping (SLAM) method based on the RGB-D sensor is widely researched in recent years. However, the accuracy of the RGB-D SLAM relies heavily on correspondence feature points, and the position would be lost in case of scenes with sparse textures. Therefore, plenty of fusion methods using the RGB-D information and inertial measurement unit (IMU) data have investigated to improve the accuracy of SLAM system. However, these fusion methods usually do not take into account the size of matched feature points. The pose estimation calculated by RGB-D information may not be accurate while the number of correct matches is too few. Thus, considering the impact of matches in SLAM system and the problem of missing position in scenes with few textures, a loose fusion method combining RGB-D with IMU is proposed in this paper. In the proposed method, we design a loose fusion strategy based on the RGB-D camera information and IMU data, which is to utilize the IMU data for position estimation when the corresponding point matches are quite few. While there are a lot of matches, the RGB-D information is still used to estimate position. The final pose would be optimized by General Graph Optimization (g2o) framework to reduce error. The experimental results show that the proposed method is better than the RGB-D camera's method. And this method can continue working stably for indoor environment with sparse textures in the SLAM system.

  11. Microbial air contamination in indoor environment of a university library.

    Science.gov (United States)

    Kalwasińska, Agnieszka; Burkowska, Aleksandra; Wilk, Iwona

    2012-01-01

    The present study was aimed at evaluating the number of bacteria and mould fungi in the indoor and outdoor environment of Toruń University Library. The sampling sites were located in the rooms serving the functions typical of libraries (i.e. in the Main Reading Room, Current Periodicals Reading Room, Collections Conservation Laboratory, Old Prints Storeroom, in rooms serving other (non-library) functions (i.e. main hall, cafeteria, and toilet) as well as outside the library building. The analyses reveal that the concentrations of bacterial as well as fungal aerosols estimated with the use of the impaction method ranged between 10(1)-10(3) CFU·m(-3), which corresponds to the concentrations normally observed in areas of this kind. Evaluation of the hygienic condition of the studied areas was based on the criteria for microbiological cleanliness in interiors submitted by the European Commission in 1993. According to this classification, the air was considered to be heavily or moderately contaminated with bacteria, while the air contamination with mould fungi was described as low or moderate. The air in the Old Prints Storeroom was considered the least contaminated with microbial aerosol.

  12. Effectiveness of Indoor Plant to Reduce CO2 in Indoor Environment

    Directory of Open Access Journals (Sweden)

    Suhaimi Mohd Mahathir

    2017-01-01

    Full Text Available Modern country strongly emphasizes on indoor air quality (IAQ because it can effect on human health and productivity. Numerous efforts were performed to make sure that sustainability of IAQ is guaranteed. In the last 4th decade, researchers discover that indoor plants have abilities to reduce indoor air pollution. Generally, plants, carbon dioxide (CO2, light, and temperature involve in the photosynthesis process. This paper intends to study the effectiveness of seven indoor plants (Anthurium, Dumb Cane, Golden Pothos, Kadaka Fern, Prayer Plant, Spider Plant, and Syngonium to reduce CO2 with different light level. This study was conducted in one cubic meter of chamber, and each plant was put into the chamber individually with CO2 concentration in the chamber is set at 1000±50ppm, and light intensities is set at 300 and 700 lux, while temperature were fixed at 25±1°C. Based on the results, only the Spider Plant was not able to absorb CO2 during the test at 300 lux of light intensity. Meanwhile, Prayer Plant performed well when tested at 300 or 700 lux of light intensity compare to other investigates plants. This study can conclude that light intensity play an important role for the plant to absorb CO2 effectively. All the indoor plants absorbed more CO2, when the light intensity is increased.

  13. An International Project on Indoor Air Quality Design and Control in Low Energy Residential Buildings

    DEFF Research Database (Denmark)

    Rode, Carsten; Abadie, Marc; Qin, Menghao

    2016-01-01

    focal points to limiting energy consumption for thermally conditioning the indoor environment will be to possibly reducing the ventilation rate, or making it in a new way demand controlled. However, this must be done such that it does not have adverse effects on indoor air quality (IAQ). Annex 68......In order to achieve nearly net zero energy use, both new and energy refurbished existing buildings will in the future need to be still more efficient and optimized. Since such buildings can be expected to be already well insulated, airtight, and have heat recovery systems installed, one of the next......, Indoor Air Quality Design and Control in Low Energy Residential Buildings, is a project under IEA’s Energy Conservation in Buildings and Communities Program (EBC), which will endeavor to investigate how future residential buildings are able to have very high energy performance whilst providing...

  14. Workshop on indoor air quality research needs

    Energy Technology Data Exchange (ETDEWEB)

    1980-01-01

    Workshop participants report on indoor air quality research needs including the monitoring of indoor air quality, report of the instrumentation subgroup of indoor air quality, health effects, and the report of the control technology session. Risk analysis studies addressing indoor environments were also summarized. (DLS)

  15. Workshop on indoor air quality research needs

    International Nuclear Information System (INIS)

    1980-01-01

    Workshop participants report on indoor air quality research needs including the monitoring of indoor air quality, report of the instrumentation subgroup of indoor air quality, health effects, and the report of the control technology session. Risk analysis studies addressing indoor environments were also summarized

  16. INDOOR POSITIONING AND NAVIGATION BASED ON CONTROL SPHERECAL PANORAMIC IMAGES

    Directory of Open Access Journals (Sweden)

    T.-C. Huang

    2016-06-01

    Full Text Available Continuous indoor and outdoor positioning and navigation is the goal to achieve in the field of mobile mapping technology. However, accuracy of positioning and navigation will be largely degraded in indoor or occluded areas, due to receiving weak or less GNSS signals. Targeting the need of high accuracy indoor and outdoor positioning and navigation for mobile mapping applications, the objective of this study is to develop a novel method of indoor positioning and navigation with the use of spherical panoramic image (SPI. Two steps are planned in the technology roadmap. First, establishing a control SPI database that contains a good number of well-distributed control SPIs pre-acquired in the target space. A control SPI means an SPI with known exterior orientation parameters, which can be solved with a network bundle adjustment of SPIs. Having a control SPI database, the target space will be ready to provide the service of positioning and navigation. Secondly, the position and orientation of a newly taken SPI can be solved by using overlapped SPIs searched from the control SPI database. The method of matching SPIs and finding conjugate image features will be developed and tested. Two experiments will be planned and conducted in this paper to test the feasibility and validate the test results of the proposed methods. Analysis of appropriate number and distribution of needed control SPIs will also be included in the experiments with respect to different test cases.

  17. Relative Panoramic Camera Position Estimation for Image-Based Virtual Reality Networks in Indoor Environments

    Science.gov (United States)

    Nakagawa, M.; Akano, K.; Kobayashi, T.; Sekiguchi, Y.

    2017-09-01

    Image-based virtual reality (VR) is a virtual space generated with panoramic images projected onto a primitive model. In imagebased VR, realistic VR scenes can be generated with lower rendering cost, and network data can be described as relationships among VR scenes. The camera network data are generated manually or by an automated procedure using camera position and rotation data. When panoramic images are acquired in indoor environments, network data should be generated without Global Navigation Satellite Systems (GNSS) positioning data. Thus, we focused on image-based VR generation using a panoramic camera in indoor environments. We propose a methodology to automate network data generation using panoramic images for an image-based VR space. We verified and evaluated our methodology through five experiments in indoor environments, including a corridor, elevator hall, room, and stairs. We confirmed that our methodology can automatically reconstruct network data using panoramic images for image-based VR in indoor environments without GNSS position data.

  18. Study on indoor thermal environment in winter for rural residences in Yulin region

    Science.gov (United States)

    Yanjun, Li; Weixiao, Han

    2018-02-01

    Yulin region is located in the northern part of Shaanxi Province, China. The winter here is very cold and it has a long duration. In this paper, a rural residence which was located in Yulin region was taken as a study object. Indoor thermal environment of the rural residence were tested, including indoor air temperature and air relative humidity. Then, test data were analyzed. It was summarized that indoor thermal environment of test room can not fully meet human thermal comfort needs, and some tactics of regulation building thermal environment were proposed. This research contributes to improvement of indoor thermal environment for local rural residences and it provides reference for rural residences in other cold regions.

  19. Improved perceived indoor environment in renovated and energy-retrofitted social housing

    DEFF Research Database (Denmark)

    Knudsen, Henrik Nellemose

    2017-01-01

    , noise from outside and too little daylight. The evaluation shows that it is possible to achieve a win-win situation, with both energy savings and improved perceived indoor environment. The evaluation also reveals that careful attention is needed to avoid introducing annoying noise from new technical......The purpose of the present study was, among other things, to evaluate how tenants perceived the indoor environment in renovated and energy-retrofitted social housing erected in the 1960s. Tenants answered a questionnaire to quantify problems and satisfaction with the indoor environment before...... and after the renovation work. A majority of tenants perceived the indoor environment improved for all parameters: temperature, draught, air quality, noise and daylight, after the renovation work. In particular, the tenants experienced fewer problems with too low temperature and draught during the winter...

  20. Consumer exposure to chemicals in indoor environment : A specific focus on chemicals from textile products

    OpenAIRE

    Wijnhoven SWP; Kooi MW; te Biesebeek JD; SIR; vgc

    2010-01-01

    Textile products in indoor environment contain a variety of chemicals. Well-known examples are flame retardants, phthalates, formaldehyde and dimethylfumarate. Consumers are potentially exposed to these chemicals since a lot of textile products are present in indoor environment (clothing, curtains, floor covering, and upholstery of furniture) and consumers are in contact with these products for up to 24 hours a day. The Food and Consumer Product Safety Authority (VWA) commissioned RIVM to mak...

  1. Influences of Green Outdoors versus Indoors Environmental Settings on Psychological and Social Outcomes of Controlled Exercise

    Science.gov (United States)

    Rogerson, Mike; Gladwell, Valerie F.; Gallagher, Daniel J.; Barton, Jo L.

    2016-01-01

    This study addressed a methodological gap by comparing psychological and social outcomes of exercise in green outdoors versus built indoors settings, whilst rigorously controlling exercise mode and intensity. The hypotheses were that greater improvements or more desirable values for directed attention, mood, perceived exertion, social interaction time, intention for future exercise behaviour and enjoyment would be associated with outdoors compared to indoors exercise. Following a baseline session, paired participants completed two conditions of 15 min of cycling on an ergometer placed outside in a natural environment and inside in a laboratory setting in a randomized, counter-balanced order. At pre- and post-exercise, directed attention was measured with the digit span backwards task, and mood was assessed with the Profile of Mood States. During the exercise session, visual and verbal interactions were recorded by means of experimenter observations. After each exercise session, participants provided self-reports of their enjoyment of the exercise, perceived exertion and intention for future exercise in the same environment. Social interaction time was significantly greater during outdoors exercise versus indoors; on average, participants engaged in three minutes more social interaction during exercise outdoors compared to indoors. Social interaction time significantly predicted intention for future exercise in the outdoors condition, but did not in the indoor condition. There was a significant time by condition interaction for directed attention. Scores worsened in the indoors condition, but improved in the outdoors condition. There was no statistically-significant time by condition interaction for mood and no significant difference between conditions for either perceived exertion or intention. Taken together, these findings show that exercise in a natural environment may promote directed attention and social interactions, which may positively influence future

  2. Desiccant wheel thermal performance modeling for indoor humidity optimal control

    International Nuclear Information System (INIS)

    Wang, Nan; Zhang, Jiangfeng; Xia, Xiaohua

    2013-01-01

    Highlights: • An optimal humidity control model is formulated to control the indoor humidity. • MPC strategy is used to implement the optimal operation solution. • Practical applications of the MPC strategy is illustrated by the case study. - Abstract: Thermal comfort is an important concern in the energy efficiency improvement of commercial buildings. Thermal comfort research focuses mostly on temperature control, but humidity control is an important aspect to maintain indoor comfort too. In this paper, an optimal humidity control model (OHCM) is presented. Model predictive control (MPC) strategy is applied to implement the optimal operation of the desiccant wheel during working hours of a commercial building. The OHCM is revised to apply the MPC strategy. A case is studied to illustrate the practical applications of the MPC strategy

  3. An Efficient Shortest Path Routing Algorithm for Directed Indoor Environments

    Directory of Open Access Journals (Sweden)

    Sultan Alamri

    2018-03-01

    Full Text Available Routing systems for outdoor space have become the focus of many research works. Such routing systems are based on spatial road networks where moving objects (such as cars are affected by the directed roads and the movement of traffic, which may include traffic jams. Indoor routing, on the other hand, must take into account the features of indoor space such as walls and rooms. In this paper, we take indoor routing in a new direction whereby we consider the features that a building has in common with outdoor spaces. Inside some buildings, there may be directed floors where moving objects must move in a certain direction through directed corridors in order to reach a certain location. For example, on train platforms or in museums, movement in the corridors may be directed. In these directed floor spaces, a routing system enabling a visitor to take the shortest path to a certain location is essential. Therefore, this work proposes a new approach for buildings with directed indoor spaces, where each room can be affected by the density of the moving objects. The proposed system obtains the shortest path between objects or rooms taking into consideration the directed indoor space and the capacity of the objects to move within each room/cell.

  4. International standards for the indoor environment. Where are we and do they apply to Asian countries?

    DEFF Research Database (Denmark)

    Olesen, Bjarne W.

    2003-01-01

    On the international level, ISO (International Organization for Standardization), CEN (European Committee for Standardization) and ASHRAE (American Society of Heating, Refrigerating and Air Conditioning Engineers) are writing and reviewing standards relating to the indoor environment on a regular...... basis. This presentation will focus on the development of standards for the indoor thermal environment and indoor air quality (ventilation). In the future, recommendations for acceptable indoor environments will be specified as classes. This allows for national differences in the requirements as well...... as for designing buildings for different quality levels. Several of these standards have been developed mainly by experts from Europe, North America and Japan. Are there, however, special considerations relating to South-East Asia (lifestyle, outdoor climate, economy) that are not dealt with in these standards...

  5. Literature survey on how different factors influence human comfort in indoor environments

    DEFF Research Database (Denmark)

    Frontczak, Monika Joanna; Wargocki, Pawel

    2011-01-01

    examined the extent to which other factors unrelated to the indoor environment, such as individual characteristics of building occupants, building-related factors and outdoor climate including seasonal changes, influence whether the indoor environment is evaluated as comfortable or not. The results suggest...... environmental conditions influencing comfort in the built environment were surveyed: thermal, visual and acoustic, as well as air quality. The literature was surveyed to determine which of these conditions were ranked by building users as being the most important determinants of comfort. The survey also...... quality. Thermal comfort is ranked by building occupants to be of greater importance compared with visual and acoustic comfort and good air quality. It also seems to influence to a higher degree the overall satisfaction with indoor environmental quality compared with the impact of other indoor...

  6. Control of indoor radon and radon progeny concentrations

    International Nuclear Information System (INIS)

    Sextro, R.G.

    1985-05-01

    There are three general categories of techniques for the control of radon and radon progeny concentrations in indoor air - restriction of radon entry, reduction of indoor radon concentrations by ventilation or air cleaning, and removal of airborne radon progeny. The predominant radon entry process in most residences appears to be pressure driven flow of soil gas through cracks or other openings in the basement, slab, or subfloor. Sealing these openings or ventilation of the subslab or subfloor space are methods of reducing radon entry rates. Indoor radon concentrations may be reduced by increased ventilation. The use of charcoal filters for removal of radon gas in the indoor air by adsorption has also been proposed. Concentrations of radon progeny, which are responsible for most of the health risks associated with radon exposures, can be controlled by use of electrostatic or mechanical filtration. Air circulation can also reduce radon progeny concentrations in certain cases. This paper reviews the application and limitations of each of these control measures and discusses recent experimental results

  7. Improving indoor air quality for poor families: a controlled experiment in Bangladesh

    Energy Technology Data Exchange (ETDEWEB)

    Dasgupta, S. (World Bank. Research-DECRG/Ru, Washington DC (United States)); Wheeler, D. (Center for Global Development, Washington DC (United States)); Huq, M. (Development Policy Group, Dhaka (Bangladesh)); Khaliquzzaman, M. (World Bank, Dhaka (Bangladesh))

    2009-02-15

    The World Health Organization's 2004 Global and Regional Burden of Disease Report estimates that acute respiratory infections from indoor air pollution (pollution from burning wood, animal dung, and other bio-fuels) kill a million children annually in developing countries, inflicting a particularly heavy toll on poor families in South Asia and Africa. This paper reports on an experiment that studied the use of different fuels in conjunction with different combinations of construction materials, space configurations, cooking locations, and household ventilation practices (use of doors and windows) as potentially-important determinants of indoor air pollution. Results from controlled experiments in Bangladesh were analyzed to test whether changes in these determinants can have significant effects on indoor air pollution. Analysis of the data shows, for example, that pollution from the cooking area is transported into living spaces rapidly and completely. Furthermore, it is important to factor in the interaction between outdoor and indoor air pollution. Hence, the optimal cooking location should take 'seasonality' in account. Among fuels, seasonal conditions seem to affect the relative severity of pollution from wood, dung, and other biomass fuels. However, there is no ambiguity about their collective impact. All are far dirtier than clean (LPG and Kerosene) fuels. The analysis concludes that if cooking with clean fuels is not possible, then building the kitchen with permeable construction material and providing proper ventilation in cooking areas will yield a better indoor health environment. (au)

  8. Emissions and fate of brominated flame retardants in the indoor environment: A critical review of modelling approaches

    Energy Technology Data Exchange (ETDEWEB)

    Liagkouridis, Ioannis, E-mail: ioannis.liagkouridis@ivl.se [IVL Swedish Environmental Research Institute, P.O. Box 21060, SE 100 31 Stockholm (Sweden); ITM Department of Applied Environmental Science, Stockholm University, SE 106 91 Stockholm (Sweden); Cousins, Ian T. [ITM Department of Applied Environmental Science, Stockholm University, SE 106 91 Stockholm (Sweden); Cousins, Anna Palm [IVL Swedish Environmental Research Institute, P.O. Box 21060, SE 100 31 Stockholm (Sweden)

    2014-09-01

    This review explores the existing understanding and the available approaches to estimating the emissions and fate of semi-volatile organic compounds (SVOCs) and in particular focuses on the brominated flame retardants (BFRs). Volatilisation, an important emission mechanism for the more volatile compounds can be well described using current emission models. More research is needed, however, to better characterise alternative release mechanisms such as direct material–particle partitioning and material abrasion. These two particle-mediated emissions are likely to result in an increased chemical release from the source than can be accounted for by volatilisation, especially for low volatile compounds, and emission models need to be updated in order to account for these. Air–surface partitioning is an important fate process for SVOCs such as BFRs however it is still not well characterised indoors. In addition, the assumption of an instantaneous air–particle equilibrium adopted by current indoor fate models might not be valid for high-molecular weight, strongly sorbing compounds. A better description of indoor particle dynamics is required to assess the effect of particle-associated transport as this will control the fate of low volatile BFRs. We suggest further research steps that will improve modelling precision and increase our understanding of the factors that govern the indoor fate of a wide range of SVOCs. It is also considered that the appropriateness of the selected model for a given study relies on the individual characteristics of the study environment and scope of the study. - Highlights: • Current emission models likely underestimate the release of low volatile BFRs from products. • Material abrasion and direct material–dust partitioning are important, yet understudied emission mechanisms. • Indoor surfaces can be significant sinks, but the mechanism is poorly understood. • Indoor fate of low volatile BFRs is strongly associated with particle

  9. Indoor Thermal Environment of Temporary Mobile Energy Shelter Houses (MeSHs in South Korea

    Directory of Open Access Journals (Sweden)

    Jeong-Gook Kim

    2015-10-01

    Full Text Available Temporary housing must be developed to support the long-term residence needs of disaster victims. The present study assesses a temporary housing unit, the so-called Mobile Energy Shelter House (MeSH, incorporating the “Korean Dwelling Insulation Standard” in order to reduce energy usage for cooling and heating. To assess energy performance, the characteristics of the indoor thermal environment were measured during the winter and summer seasons. In summer, at maximum insolation, the outdoor temperature was 37.6 °C and the indoor temperature of the MeSH ranged from 18 to 24 °C when the cooling system was not used. Conversely, during winter, the average outdoor temperature was −11.3 °C and the indoor temperature ranged from 16.09 to 20.63 °C when a temperature-controlled floor-heating was installed. Furthermore, the Predicted Mean Vote (PMV was adopted to determine whether the ISO 7730 comfort criterion (i.e., PMV range from −0.5 to +0.5 was achieved. Based on the calculations presented here, PMV in summer ranged from −1.21 to +1.07 and that in winter ranged from −0.08 to −0.85, suggesting that the thermal environment is not always comfortable for occupants in either summer or winter. Nevertheless, the ISO comfort criterion can be achieved through varying air velocity in summer and changing clothing characteristics in winter. A comparison between yearly energy demand of existing characteristic temporary housing (Shelter House and the MeSH modules used in this study was performed. The simulation results show a 60% difference in energy demand between MeSH and existing temporary housing shelter houses.

  10. Coordinate-Based Clustering Method for Indoor Fingerprinting Localization in Dense Cluttered Environments

    Directory of Open Access Journals (Sweden)

    Wen Liu

    2016-12-01

    Full Text Available Indoor positioning technologies has boomed recently because of the growing commercial interest in indoor location-based service (ILBS. Due to the absence of satellite signal in Global Navigation Satellite System (GNSS, various technologies have been proposed for indoor applications. Among them, Wi-Fi fingerprinting has been attracting much interest from researchers because of its pervasive deployment, flexibility and robustness to dense cluttered indoor environments. One challenge, however, is the deployment of Access Points (AP, which would bring a significant influence on the system positioning accuracy. This paper concentrates on WLAN based fingerprinting indoor location by analyzing the AP deployment influence, and studying the advantages of coordinate-based clustering compared to traditional RSS-based clustering. A coordinate-based clustering method for indoor fingerprinting location, named Smallest-Enclosing-Circle-based (SEC, is then proposed aiming at reducing the positioning error lying in the AP deployment and improving robustness to dense cluttered environments. All measurements are conducted in indoor public areas, such as the National Center For the Performing Arts (as Test-bed 1 and the XiDan Joy City (Floors 1 and 2, as Test-bed 2, and results show that SEC clustering algorithm can improve system positioning accuracy by about 32.7% for Test-bed 1, 71.7% for Test-bed 2 Floor 1 and 73.7% for Test-bed 2 Floor 2 compared with traditional RSS-based clustering algorithms such as K-means.

  11. Coordinate-Based Clustering Method for Indoor Fingerprinting Localization in Dense Cluttered Environments.

    Science.gov (United States)

    Liu, Wen; Fu, Xiao; Deng, Zhongliang

    2016-12-02

    Indoor positioning technologies has boomed recently because of the growing commercial interest in indoor location-based service (ILBS). Due to the absence of satellite signal in Global Navigation Satellite System (GNSS), various technologies have been proposed for indoor applications. Among them, Wi-Fi fingerprinting has been attracting much interest from researchers because of its pervasive deployment, flexibility and robustness to dense cluttered indoor environments. One challenge, however, is the deployment of Access Points (AP), which would bring a significant influence on the system positioning accuracy. This paper concentrates on WLAN based fingerprinting indoor location by analyzing the AP deployment influence, and studying the advantages of coordinate-based clustering compared to traditional RSS-based clustering. A coordinate-based clustering method for indoor fingerprinting location, named Smallest-Enclosing-Circle-based (SEC), is then proposed aiming at reducing the positioning error lying in the AP deployment and improving robustness to dense cluttered environments. All measurements are conducted in indoor public areas, such as the National Center For the Performing Arts (as Test-bed 1) and the XiDan Joy City (Floors 1 and 2, as Test-bed 2), and results show that SEC clustering algorithm can improve system positioning accuracy by about 32.7% for Test-bed 1, 71.7% for Test-bed 2 Floor 1 and 73.7% for Test-bed 2 Floor 2 compared with traditional RSS-based clustering algorithms such as K-means.

  12. Reply to "Can the levels of Can f 1 in indoor environments be evaluated without considering passive transport of allergen indoors?"

    NARCIS (Netherlands)

    Krop, E.J.M.; Vredegoor, D.W.; Chapman, M.D.; Willemse, A.; Heederik, D.J.J.

    2013-01-01

    Response to Liccardi G, Salzillo A, Piccolo A, D’Amato M, D’Amato G. Can the levels of Can f 1 in indoor environments be evaluated without considering passive transport of allergen indoors? J Allergy Clin Immunol 2013;131:1258-9.

  13. Microbial load in indoor sport environments: new quality issues by molecular biology

    Directory of Open Access Journals (Sweden)

    Vincenzo Romano Spica

    2004-12-01

    Full Text Available

    The quality of hygiene found in sporting environments represents an emergent requirement in societies of industrialised countries.

    Besides safety issues, the microbial load of indoor air, water and surfaces affects comfort and performance. Recent studies have identified fungi as the quantitatively most important component, of unhealthy indoor air.

    Few studies have been carried out regarding indoor sport, recreational and rehabilitative facilities, such as swimming pools, saunas and spas. The aim of our study is to determine the extent of fungal and microbial contamination in indoor swimming pool environments, by means of both morphological and molecular typing of isolated species.

    Establishment of appropriate standardised monitoring procedures prevents infections and improves quality.

  14. Bioaerosols in indoor environment - a review with special reference to residential and occupational locations

    OpenAIRE

    Mandal, J; Brandl, H

    2011-01-01

    Bioaerosols such as bacterial and fungal cells and their spores are - along with non-biological particles - part of indoor airborne particulate matter and have been related since a long time to health issues of human beings as well as flora, and fauna. To identify the different risks and to establish exposure thresholds, microbiology of air samples from a series of indoor environments must be characterized, i.e. the different microorganisms (bacteria and fungi) must be identified and quantifi...

  15. User based preference indoor climate control

    OpenAIRE

    Zeiler, W.; Boxem, G.; Houten, van, M.A.; Wortel, W.; Velden, van der, J.A.J.; Kamphuis, I.G.; Hommelberg, M.P.F.; Tanabe, S.-I.; Kato, S.

    2007-01-01

    In comfort control strategy there is an exciting development based on inclusive design: the user’s preferences and their behaviour have become central in the building services control strategy. Synergy between end-user and building is the ultimate in the intelligent comfort control concept. This new comfort control technology is based on the use of the latest development in agent technology and can further reduce energy consumption of buildings while at the same time improve individual comfor...

  16. User based preference indoor climate control

    NARCIS (Netherlands)

    Zeiler, W.; Boxem, G.; Houten, van M.A.; Wortel, W.; Velden, van der J.A.J.; Kamphuis, I.G.; Hommelberg, M.P.F.; Tanabe, S.-I.; Kato, S.

    2007-01-01

    In comfort control strategy there is an exciting development based on inclusive design: the user’s preferences and their behaviour have become central in the building services control strategy. Synergy between end-user and building is the ultimate in the intelligent comfort control concept. This new

  17. Test and analysis of indoor environment of dormitories of universities in autumn

    Science.gov (United States)

    Chen, Shijia

    2017-03-01

    In this paper, the indoor thermal and humid environment, luminous environment and acoustic environment of college dormitories in Baoding are tested and conducted a questionnaire survey. From the test, the subjective feelings and the objective evaluation parameters of the students in the dormitory were obtained. At last, the differences of thermal comfort, luminous environment and acoustic environment caused by students' different living habits and adaptability were analyzed.

  18. Ozone initiated reactions and human comfort in indoor environments

    DEFF Research Database (Denmark)

    Tamas, Gyöngyi

    2006-01-01

    Chemical reactions between ozone and pollutants commonly found indoors have been suggested to cause adverse health and comfort effects among building occupants. Of special interest are reactions with terpenes and other pollutants containing unsaturated carbon-carbon bonds that are fast enough...... to occur under normal conditions in various indoor settings. These reactions are known to occur both in the gas phase (homogeneous reactions) and on the surfaces of building materials (heterogeneous reactions), producing a number of compounds that can be orders of magnitude more odorous and irritating than...... their precursors. The present thesis investigates the effects of ozone-initiated reactions with limonene and with various interior surfaces, including those associated with people, on short-term sensory responses. The evaluations were conducted using a perceived air quality (PAQ) method introduced by Fanger (1988...

  19. How to Ensure Low Radon Concentrations in Indoor Environments

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn; Wraber, Ida Kristina

    2011-01-01

    This paper focuses on methods for measuring radon levels in the indoor air in buildings as well as on concrete solutions that can be carried out in the building to prevent radon leakage and to lower the radon concentration in the indoor air of new buildings. The radon provision in the new Danish...... Building Regulations from 2010 has been tightened as a result of new recommendations from the World Health Organization. Radon can cause lung cancer and it is not known whether there is a lower limit for its harmfulness. It is therefore important to reduce the radon concentration as much as possible in new...... buildings. The airtightness is a major factor when dealing with radon in buildings. Above the ground it is important to build airtight in compliance with energy requirements and against the ground it is important to prevent radon from seeping into the building. There is a direct connection between...

  20. ASSESSMENT OF THE INDOOR ENVIRONMENT AND IMPLICATIONS FOR HEALTH IN ROMA VILLAGES IN SLOVAKIA AND ROMANIA

    Science.gov (United States)

    Majdan, Marek; Coman, Alexandru; Gallová, Eva; Ďuricová, Janka; Kállayová, Daniela; Kvaková, Mária; Bošák, Ľuboš

    2013-01-01

    SUMMARY Objectives The objective of this paper is to provide information on indoor air quality and on the quality of the broader indoor environment of the houses in Roma villages in Slovakia and Romania and to discuss possible implications for health. Methods Indoor air was sampled in 11 houses in a Romanian Roma village and in 19 houses in a Slovakian Roma village. Levels of Carbon Monoxide (CO), Carbon Dioxide (CO2), total particulate matter (PM), temperature and humidity were measured. A questionnaire and a checklist were used to obtain additional information on the indoor environment and behavioural factors. We have sampled the same houses in winter and in summer. Results Levels of CO and CO2 were higher in winter in both countries as compared to summer. The limit value of 10 mg/m3 CO was exceeded in a few cases in both countries. In general, levels of CO, CO2 and PM were higher in Romania. Further environmental and behavioural hazards such as indoor smoking, pets inside or lack of ventilation were found. The reported self-perceived quality of the indoor environment was poor in many aspects. Conclusions Our findings of CO, CO2 and PM levels suggest that indoor air pollution in Roma settlements has the potential to be a health threat. The fact that the inhabitants spend a relatively long time inside the houses and that a number of additional environmental and behavioural hazards were identified by our study emphasizes the importance of the indoor air quality for health and thus priority attention should be paid to these issues by health authorities and researchers. Further research is essential and study designs must consider cultural background and specific characteristics of the community, especially in order to obtain valid data on health outcomes. PMID:23285520

  1. Plastics additives in the indoor environment-flame retardants and plasticizers

    International Nuclear Information System (INIS)

    Wensing, M.; Uhde, E.; Salthammer, T.

    2005-01-01

    Phthalic acid esters and phosphororganic compounds (POC) are generally known as semivolatile organic compounds (SVOCs) and are frequently utilized as plasticizers and flame retardants in commercial products. In the indoor environment, both compound groups are released from a number of sources under normal living conditions and accumulate in air and dust. Therefore, inhalation of air and ingestion of house dust have to be considered as important pathways for the assessment of exposure in living habitats. Especially in the case of very young children, the oral and dermal uptake from house dust might be of relevance for risk assessment. A critical evaluation of indoor exposure to phthalates and POC requires the determination of the target compounds in indoor air and house dust as well as emission studies. The latter are usually carried out under controlled conditions in emission test chambers or cells. Furthermore, chamber testing enables the determination of condensable compounds by fogging sampling. In the case of automobiles, specific scenarios have been developed to study material emissions on a test stand or to evaluate the exposure of users while the vehicle is driving. In this review, results from several studies are summarized and compared for seven phthalic esters and eight POC. The available data for room air and dust differ widely depending on investigated compound and compartment. Room air studies mostly include only a limited number of measurements, which makes a statistical evaluation difficult. The situation is much better for house dust measurements. However, the composition of house dust is very inhomogeneous and the result is strongly dependent on the particle size distribution used for analysis. Results of emission studies are presented for building products, electronic equipment, and automobiles. Daily rates for inhalation and dust ingestion of phthalic esters and POC were calculated from 95-percentiles or maximum values. A comparison of the data

  2. Caring buildings: user based indoor climate control

    NARCIS (Netherlands)

    Zeiler, W.; Houten, van M.A.

    2007-01-01

    Global warming, caused largely by energy consumption, has become a major problem. In comfort control strategy there is an exciting development based on inclusive design: the user's preferences and their behaviour have become central in the building services control strategy. Synergy between end-user

  3. Controlling indoor climate. Passive cooling of residential buildings in hot-humid climates in China

    Energy Technology Data Exchange (ETDEWEB)

    Zhiwu, Wang

    1996-10-01

    Overheating is a paramount problem in residential buildings in hot and humid climates in China during summer. This study aims to deal with the overheating problem and the problem of poor air quality in dwellings. The main objective is to improve indoor thermal conditions by passive cooling approaches, climatisation techniques in buildings without auxiliary cooling from air conditioning equipment. This thesis focuses on the study of cross-ventilation in apartments, which is one of the most effective ways of natural cooling in a hot humid climate, but is also one of the least understood parts in controlling indoor climate. The Computational Fluid Dynamics (CFD) technique is used, which is a new approach, since cross-ventilation studies have been conventionally made by wind tunnel tests. The validations of the CFD technique are examined by a comparison between wind tunnel tests and computer simulations. The factors influencing indoor air movement are investigated for a single room. Cross-ventilation in two apartments is studied, and the air change efficiency in a Chinese kitchen is calculated with CFD techniques. The thermal performance of ventilated roofs, a simple and widely used type of roof in the region, is specially addressed by means of a full-scale measurement, wind tunnel tests and computer simulations. An integrated study of passive cooling approaches and factors affecting indoor thermal comfort is carried out through a case study in a southern Chinese city, Guangzhou. This thesis demonstrates that passive cooling measure have a high potential in significantly improving indoor thermal conditions during summer. This study also gives discussions and conclusions on the evaluation of indoor thermal environment; effects influencing cross-ventilation in apartments; design guidelines for ventilated roofs and an integrated study of passive cooling. 111 refs, 83 figs, 65 tabs

  4. The world's largest study of the indoor environment in commercial kitchens

    DEFF Research Database (Denmark)

    Olesen, Bjarne W.; Simone, Angela

    2013-01-01

    The International Centre for Indoor Environment and Energy (ICIEE) at DTU Civil Engineering has conducted a study on the thermal conditions of the working environment in more than 100 commercial kitchens in the USA during summer and winter. The study shows that employees generally feel the working...

  5. Experimental Study of RF Energy Transfer System in Indoor Environment

    International Nuclear Information System (INIS)

    Adami, S-E; Proynov, P P; Stark, B H; Hilton, G S; Craddock, I J

    2014-01-01

    This paper presents a multi-transmitter, 2.43 GHz Radio-Frequency (RF) wireless power transfer (WPT) system for powering on-body devices. It is shown that under typical indoor conditions, the received power range spans several orders of magnitude from microwatts to milliwatts. A body-worn dual-polarised rectenna (rectifying antenna) is presented, designed for situations where the dominant polarization is unpredictable, as is the case for the on-body sensors. Power management circuitry is demonstrated that optimally loads the rectenna even under highly intermittent conditions, and boosts the voltage to charge an on-board storage capacitor

  6. Experimental Study of RF Energy Transfer System in Indoor Environment

    Science.gov (United States)

    Adami, S.-E.; Proynov, P. P.; Stark, B. H.; Hilton, G. S.; Craddock, I. J.

    2014-11-01

    This paper presents a multi-transmitter, 2.43 GHz Radio-Frequency (RF) wireless power transfer (WPT) system for powering on-body devices. It is shown that under typical indoor conditions, the received power range spans several orders of magnitude from microwatts to milliwatts. A body-worn dual-polarised rectenna (rectifying antenna) is presented, designed for situations where the dominant polarization is unpredictable, as is the case for the on-body sensors. Power management circuitry is demonstrated that optimally loads the rectenna even under highly intermittent conditions, and boosts the voltage to charge an on-board storage capacitor.

  7. Investigation of the Indoor Environment in a Passive House Apartment Building Heated by Ventilation Air

    DEFF Research Database (Denmark)

    Lysholt Hansen, MathiasYoung Bok; Koulani, Chrysanthi Sofia; Peuhkuri, Ruut Hannele

    2014-01-01

    comfort and the performance of the air heating system and solar shading. Thermal comfort category B according to ISO 7730 was obtained in the building during field measurements, indicating that the air heating system was able to maintain comfort conditions in winter, when the outdoor temperature had been...... building project finished medio 2012. The design challenge was met with a concept of air heating that is individually controlled in every room. It also applies external solar shading. This study used indoor climate measurements and dynamic simulations in one of these apartment buildings to evaluate thermal...... unusual low for a longer period. The dynamic simulations also indicated that air heating during winter can provide a comfortable thermal environment. Dynamic simulations also demonstrated that during summer, apartments with automatic external solar screens had no serious overheating, whereas in apartments...

  8. Ionising radiations - an ecological problem of indoor architectural environment

    International Nuclear Information System (INIS)

    Djukanovic, M.

    1995-01-01

    Architectural buildings are assessed not only for their esthetic characteristics but human settlements are considered now, as ecosystems and homes and flats as habitats (bio tops). Because of that healthy environment and influences of nonpolluting factors are of a great importance. The use of appropriate building materials harmless to health, contrary to the use of those that emit radon with its ionising effects and consequent health hazards, is of a great importance, too. The purpose of this paper is to emphasize the importance of investigation of building materials before their use, as well as the importance of quality control of soil where the construction is planned. (author)

  9. Genetic diversity of Aspergillus fumigatus in indoor hospital environments.

    Science.gov (United States)

    Araujo, Ricardo; Amorim, António; Gusmão, Leonor

    2010-09-01

    Environmental isolates of Aspergillus fumigatus are less studied than those recovered from clinical sources. In the present study, the genetic diversity among such environmental isolates was assessed, as well as their dispersion ability and the acquisition of new strains in 19 medical units of the same hospital. A. fumigatus isolates were genotyped using a single multiplex PCR-based reaction with eight microsatellite markers and an insertion/deletion polymorphism. A total of 130 unique genotypes were found among a total of 250 A. fumigatus isolates. Genotypic diversity ranged from 0.86 to 1 in samples from hospital rooms, and there was no correlation between these samples and the presence of high-efficiency particulate air filters or any other air filtration system. Four of the six most prevalent A. fumigatus strains were recovered from water samples. The occurrence of microvariation was common among environmental isolates, which affected each of the microsatellite markers. The assessment of the genetic diversity of A. fumigatus is a useful tool for illustrating the presence or absence of specific clonal populations in a clinical setting. A. fumigatus populations were highly dynamic indoors, and new populations were found in just a few months. Due to the high indoor dispersion capability of A. fumigatus, more attention should be given to strains with increased pathogenic potential or reduced susceptibility to anti-fungal drugs.

  10. Managing the indoor environment and energy efficiency in historical buildings

    Energy Technology Data Exchange (ETDEWEB)

    Huovila, P., Email: pekka.huovila@vtt.fi

    2012-06-15

    In Italy there are a lot of historical buildings that are relevant in cultural, architectural and artistic terms. Such heritage needs a constant process of renovation to keep the buildings secure, safe and efficient and to make them suitabled for host offices, museums, events and art exhibitions. Unfortunately, most of these renovation activities consider only either the security issues or outward appearance or the indoor conditions or the installations; all actions are independently designed and implemented, and an integrated approach is missing. Italian public bodies strongly need support and guidelines to write optimal tenders for building refurbishments. In this paper, we present a methodology for assessing the state of building and defining tender requirements. The methodology is based on the definition of performance indicators, related to security against human threats, thermal and hygrometric quality, living indoor conditions, air quality, lighting conditions, resilience and management of emergencies in case of natural disasters, accessibility, etc. A very important aspect that the methodology considers is compliance with regulations. Also some economical aspects will be considered. The methodology is implemented in a decision- support software tool that presents the different indicators in relation to each other, evaluating performance indices. These indices could be used to simulate different solutions and help choose the best one. Particular attention is paid to how the results are shown to end users. (orig.)

  11. Control methods of radon and its progeny concentration in indoor atmosphere

    International Nuclear Information System (INIS)

    Ramachandran, T.V.; Subba Ramu, M.C.

    1990-01-01

    Exposure to radon-222 and its progeny in indoor atmosphere can result in significant inhalation risk to the population particularly to those living in houses with much higher levels of Rn. There are three methods generally used for the control of Rn and its progeny concentration in the indoor environment: (1) restricting the radon entry, (2) reduction of indoor radon concentration by ventilation or by aircleaning and (3) removal of airborne radon progeny by aerosol reduction. Prominent process of radon entry in most of the residence appears to be the pressure driven flow of soil gas through cracks or through other openings in the basements slab or subfloor. Sealing off these openings or ventilation of the slab or subfloor spaces are the methods of reducing the radon entry rate. Indoor radon progeny levels can also be reduced by decreasing the aerosol load in the dwellings. The results of a few experiments carried out to study the reduction in the working level concentration of radon, by decreasing the aerosol load are discussed in this paper. (author). 9 tabs., 8 figs., 37 refs

  12. Smart indoor climate control in precision livestock farming

    DEFF Research Database (Denmark)

    Zhang, Guoqiang; Bjerg, Bjarne Schmidt; Wang, Xiaoshuai

    2016-01-01

    One of the major objectives of precision livestock farming (PLF) is to provide an optimal thermal climate control in the animal occupant zones for promoting animal production and wellbeing. To achieve this goal, smart climate models that reflect the needs of different animal species and ages or f...... condition in AOZ. In addition, the paper presents a fundamental principle of development of an integrated indoor climate sensor to reflect animal thermal wellbeing and techniques that could be used for a smart system design and control are discussed....

  13. Impact of climate change on the domestic indoor environment and associated health risks in the UK.

    Science.gov (United States)

    Vardoulakis, Sotiris; Dimitroulopoulou, Chrysanthi; Thornes, John; Lai, Ka-Man; Taylor, Jonathon; Myers, Isabella; Heaviside, Clare; Mavrogianni, Anna; Shrubsole, Clive; Chalabi, Zaid; Davies, Michael; Wilkinson, Paul

    2015-12-01

    There is growing evidence that projected climate change has the potential to significantly affect public health. In the UK, much of this impact is likely to arise by amplifying existing risks related to heat exposure, flooding, and chemical and biological contamination in buildings. Identifying the health effects of climate change on the indoor environment, and risks and opportunities related to climate change adaptation and mitigation, can help protect public health. We explored a range of health risks in the domestic indoor environment related to climate change, as well as the potential health benefits and unintended harmful effects of climate change mitigation and adaptation policies in the UK housing sector. We reviewed relevant scientific literature, focusing on housing-related health effects in the UK likely to arise through either direct or indirect mechanisms of climate change or mitigation and adaptation measures in the built environment. We considered the following categories of effect: (i) indoor temperatures, (ii) indoor air quality, (iii) indoor allergens and infections, and (iv) flood damage and water contamination. Climate change may exacerbate health risks and inequalities across these categories and in a variety of ways, if adequate adaptation measures are not taken. Certain changes to the indoor environment can affect indoor air quality or promote the growth and propagation of pathogenic organisms. Measures aimed at reducing greenhouse gas emissions have the potential for ancillary public health benefits including reductions in health burdens related heat and cold, indoor exposure to air pollution derived from outdoor sources, and mould growth. However, increasing airtightness of dwellings in pursuit of energy efficiency could also have negative effects by increasing concentrations of pollutants (such as PM2.5, CO and radon) derived from indoor or ground sources, and biological contamination. These effects can largely be ameliorated by mechanical

  14. A study on subjective preference to daylit residential indoor environment using conjoint analysis

    Energy Technology Data Exchange (ETDEWEB)

    Cheung, H.D.; Chung, T.M. [Department of Building Services Engineering, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong (China)

    2008-12-15

    This paper reports a study of the subjective preference to daylit indoor environment of a residential room using conjoint analysis, which is a highly reputable method used to analyze the mutual relationships among different attributes. Seven influential attributes were selected in the view of daylight performance assessment. They include 'general brightness', 'desktop brightness', 'perceived glare', 'sunlight penetration', 'quality of view', 'user friendliness of shading control' and 'impact on energy'. Each of them has two levels. A total of eight combinations (profiles) of attributes with various levels were established by adopting fractional factorial design. Subjects were asked to rank-order the eight profiles according to their preference in terms of daylit environment of a residential room. The study aims at finding out the relative impact of the seven selected attributes to the overall daylight performance and seeking an organized assessment method for a residential daylit environment. Conjoint analysis found that the seven attributes have importance level in the order of 'quality of view', 'general brightness', 'impact on energy', 'user friendliness of shading control', 'perceived glare', 'desktop brightness' and 'sunlight penetration'. (author)

  15. Detection of fluorotelomer alcohols in indoor environments and their relevance for human exposure.

    Science.gov (United States)

    Schlummer, Martin; Gruber, Ludwig; Fiedler, Dominik; Kizlauskas, Markus; Müller, Josef

    2013-07-01

    Fluorotelomer alcohols (FTOH) are important precursors of perfluorinated carboxylic acids (PFCA). These neutral and volatile compounds are frequently found in indoor air and may contribute to the overall human exposure to per- and polyfluorinated alkyl substances (PFAS). In this study air samples of ten workplace environments and a car interior were analysed. In addition, extracts and emissions from selected outdoor textiles were analysed in order to establish their potential contribution to the indoor levels of the above-mentioned compounds. Concentrations of FTOHs measured in air ranged from 0.15 to 46.8, 0.25 to 286, and 0.11 to 57.5ng/m(3) for 6:2, 8:2 and 10:2 FTOHs, respectively. The highest concentrations in air were identified in shops selling outdoor clothing, indicating outdoor textiles to be a relevant source of FTOH in indoor workplace environments. Total amounts of FTOH in materials of outdoor textiles accounted for selling outdoor textiles contains the highest levels of FTOH. Exposure of humans to perfluorooctanoic acid (PFOA) through absorption of FTOH and subsequent degradation is discussed on the basis of indoor air levels. Calculation of indoor air-related exposure using the median of the measured air levels revealed that exposure is on the same order of magnitude as the recently reported dietary intakes for a background-exposed population. On the basis of the 95th percentile, indoor air exposure to PFOA was estimated to exceed dietary exposure. However, indoor air-related intakes of FTOH are far below the tolerable daily intake (TDI) of PFOA, indicating that there is no risk to health, even when assuming an unrealistic complete degradation of FTOH into PFOA. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. Do indoor environments in schools influence student performance? A review of the literature

    Energy Technology Data Exchange (ETDEWEB)

    Mendell, Mark J.; Heath, Garvin A.

    2004-11-24

    Limited research is available on potential adverse effects of school environments on academic performance, despite strong public concern. We examine the scientific evidence relevant to this relationship by reviewing available research relating schools and other indoor environments to human performance or attendance. As a primary focus, we critically review evidence for direct relationships between indoor environmental quality (IEQ) in buildings and performance or attendance. As a secondary focus, we summarize, without critique, evidence on potential connections indirectly linking IEQ to performance or attendance: relationships between IEQ and health, between health and performance or attendance, and between attendance and performance. The most persuasive direct evidence showed increases in indoor concentrations of nitrogen dioxide and outdoor concentrations of several specific pollutants to be related to reduced school attendance. The most persuasive indirect evidence showed indoor dampness and microbiologic pollutants to be related to asthma and respiratory infections, which have in turn been related to reduced performance and attendance. Furthermore, a substantial scientific literature links poor IEQ (e.g., low ventilation rate, excess moisture or formaldehyde) with respiratory and other health effects in children and adults. Overall, evidence suggests that poor IEQ in schools can influence the performance and attendance of students, primarily through health effects from indoor pollutants. Also, inadequate IEQ in schools seems sufficiently common to merit strong public concern. Evidence is available to justify (1) immediate actions to protect IEQ in schools and (2) focused research on exposures, prevention, and causation, to better guide policies and actions on IEQ in schools.

  17. Effect of ecosystem services provided by urban greenb infrastructure on indoor environment: a literature review

    NARCIS (Netherlands)

    Wang, Y.; Bakker, F.; Groot, de R.S.; Woertche, H.

    2014-01-01

    The influence of urban green infrastructure on the indoor environment and the effects on human comfort and economic consequences are still unclear. This paper gives a systematic overview of the relationship, in terms of so-called ‘ecosystem services’, between urban green infrastructure and the

  18. RELATIVE PANORAMIC CAMERA POSITION ESTIMATION FOR IMAGE-BASED VIRTUAL REALITY NETWORKS IN INDOOR ENVIRONMENTS

    Directory of Open Access Journals (Sweden)

    M. Nakagawa

    2017-09-01

    Full Text Available Image-based virtual reality (VR is a virtual space generated with panoramic images projected onto a primitive model. In imagebased VR, realistic VR scenes can be generated with lower rendering cost, and network data can be described as relationships among VR scenes. The camera network data are generated manually or by an automated procedure using camera position and rotation data. When panoramic images are acquired in indoor environments, network data should be generated without Global Navigation Satellite Systems (GNSS positioning data. Thus, we focused on image-based VR generation using a panoramic camera in indoor environments. We propose a methodology to automate network data generation using panoramic images for an image-based VR space. We verified and evaluated our methodology through five experiments in indoor environments, including a corridor, elevator hall, room, and stairs. We confirmed that our methodology can automatically reconstruct network data using panoramic images for image-based VR in indoor environments without GNSS position data.

  19. Performance of Multi-Carrier Access Schemes with Receiver Impairments in Down Link Indoor Environment

    DEFF Research Database (Denmark)

    Das, Suvra Sekhar; Rao, Raieshwar Kurapati; Prasad, Ramjee

    2006-01-01

    impairments, such as synchronization error and channel estimation errors. This work is targeted towards unified verification of performance of the schemes for different spreading gains, load conditions and sub carrier grouping schemes in quasi static realistic indoor channel environment in the presence...

  20. Exposure to 27 polychlorinated biphenyls in the indoor environment of a workplace

    DEFF Research Database (Denmark)

    Pedersen, Ellen Bøtker; Ebbehøj, N E; Göen, T

    2016-01-01

    -chlorinated congeners. Health effect from this little-acknowledged exposure has not yet been documented, but data supporting lack of effect are sparse and research generating information on effect of exposure to specific congeners including at levels relevant for the indoor environment should be encouraged....

  1. Influence of Indoor Environment and Occupant Behaviour on Energy Consumption in Passive House Apartments

    DEFF Research Database (Denmark)

    Skød Søvsø, Asger; Peuhkuri, Ruut; Andersen, Rune Korsholm

    2015-01-01

    In 2012 Køge Boligselskab built 9 building blocks totalling 126 passive house apartments. Their monitored space heating demand (SHD) has been a lot higher than the passive house requirements. The aim of this study was to identify why, and how it relates to indoor environment and occupant behaviour...

  2. Thermal Analysis--Human Comfort--Indoor Environments. NBS Special Publication 491.

    Science.gov (United States)

    Mangum, Billy W., Ed.; Hill, James E., Ed.

    Included in these proceedings are 11 formal papers presented by leading researchers in the field of thermal comfort and heat stress at a symposium held for the purpose of exploring new aspects of indoor thermal environments, caused primarily by the impact of energy conservation in new and existing buildings. The contributed papers were from…

  3. Structural Model for the Effects of Perceived Indoor Work Environment on Sick Building Syndrome and Stress

    Directory of Open Access Journals (Sweden)

    Abdullah Nor Hazana

    2016-01-01

    Full Text Available Sick Building syndrome (SBS and stress have a prevalent influence on organizational productivity and competitiveness. Unhealthy employees not only tend to have high medical leaves but also low productivity due to ailments and discomforts. Studies that investigate the effects of indoor work environment on Sick Building Syndrome (SBS have yielded mixed results while their effect on stress has not been empirically established. Furthermore, studies that simultaneously investigate both SBS and stress are almost non-existent. Thus, this study aimed to study the effects of perceived indoor work environment on SBS and stress and the link between SBS and stress. A cross-sectional survey participated by 598 employees from various industries was conducted from September to October 2015. Data were analyzed using Partial Least Square Structural Equation Modeling (PLS-SEM to assess both the measurement model and the path structure. The results suggest that indoor work environment has significant yet the weak effect on SBS while it has no effect on stress. However, SBS has a strong significant relationship with stress. The implication of this study on the importance of conducive indoor work environment is discussed with suggestions for future studies.

  4. Remote Control of a Mobile Robot for Indoor Patrol

    Directory of Open Access Journals (Sweden)

    Shih-Yao Juang

    2016-03-01

    Full Text Available This study applies smartphone, Bluetooth, and Wi-Fi wireless network to control a wheeled mobile robot (WMR remotely. The first part of this study demonstrates that the WMR can be controlled manually by a smartphone. The smartphone can remotely control the WMR for forward, backward, left-turn, and right-turn operations. The second part of this article presents object tracking. The WMR can follow a moving object through the use of image processing for object tracking and distance detection. In the third part, infrared sensor and fuzzy system algorithms are integrated into the control scheme. Through wall-following and obstacle-avoidance control, the WMR can successfully perform indoor patrol.

  5. Airborne contamination in the indoor environment and its implications for dose

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, K.G.; Roed, J.; Byrne, M.A.; Hession, H.; Clark, P.; Elahi, E.; Buskov, A.; Hou, X.L.; Prip, H.; Olsen, S.K.; Roed, T

    2004-04-01

    Previous work has indicated that radiation doses from deposition on human skin, hair and clothing may contribute significantly to the dose received after a major nuclear accident, such as that, which happened at Chernobyl in 1986. The available data was, however, sparse and associated with considerable variation, clearly showing a need for further investigations to verify preliminary conclusions, examine processes in greater detail and identify important factors causing the observed parameter variation. For instance, the impacts of thermophoresis, electrophoresis, skin moisture and wind speed on the deposition of contaminant aerosol were examined, and since the previous measurements had indicated that elemental iodine could be a particularly problematic contaminant, experimental work was additionally undertaken to examine the process of deposition of this species to skin. Since both clearance and percutaneous penetration of deposited contaminants could play important roles in determining doses, experimental programmes were dedicated to the identification of parameters of interest in these contexts. Also doses from contamination on different surfaces in the indoor environment have in the past traditionally been neglected, and a theoretical approach, based on measurements, was developed for accurate prediction of these doses under different conditions. Also resuspension of deposited matter and its role in dose formation, by subsequent deposition or inhalation, was investigated through experiments. Contact transfer of contaminants from an indoor surface to human skin may give yet another contribution to dose and also the relevant parameters in this direction were examined experimentally. The ultimate goal of the investigations was to enable the determination of the various contributions to dose in a contaminated indoor environment. A model methodology was developed and an example of its use was given. It was found that after a major nuclear accident, doses from indoor

  6. An overview of thoron and its progeny in the indoor environment

    International Nuclear Information System (INIS)

    McLaughlin, J.

    2010-01-01

    An account is given of the behaviour of thoron and its progeny in the indoor environment. Emphasis is placed on the spatial distribution of these radionuclides in room air and on their interactions with indoor aerosols. How these aspects of thoron and progeny behaviour give rise to special problems for measuring them and assessing their radiological impact are described. Descriptions and comparisons are given of a range of thoron and progeny measurement techniques both passive and active. Recent progress in thoron dosimetry is described as well as compared with radon dosimetry. The results of some indoor thoron and progeny surveys carried out in different countries in recent years are given. As an example of this a summary account is presented of a recently concluded survey of thoron and its airborne progeny in over 200 houses in Ireland. (authors)

  7. Indoors forensic entomology: colonization of human remains in closed environments by specific species of sarcosaprophagous flies.

    Science.gov (United States)

    Pohjoismäki, Jaakko L O; Karhunen, Pekka J; Goebeler, Sirkka; Saukko, Pekka; Sääksjärvi, Ilari E

    2010-06-15

    Fly species that are commonly recovered on human corpses concealed in houses or other dwellings are often dependent on human created environments and might have special features in their biology that allow them to colonize indoor cadavers. In this study we describe nine typical cases involving forensically relevant flies on human remains found indoors in southern Finland. Eggs, larvae and puparia were reared to adult stage and determined to species. Of the five species found the most common were Lucilia sericata Meigen, Calliphora vicina Robineau-Desvoidy and Protophormia terraenovae Robineau-Desvoidy. The flesh fly Sarcophaga caerulescens Zetterstedt is reported for the first time to colonize human cadavers inside houses and a COI gene sequence based DNA barcode is provided for it to help facilitate identification in the future. Fly biology, colonization speed and the significance of indoors forensic entomological evidence are discussed. (c) 2010 Elsevier Ireland Ltd. All rights reserved.

  8. Adaptive Indoor Positioning Model Based on WLAN-Fingerprinting for Dynamic and Multi-Floor Environments

    Directory of Open Access Journals (Sweden)

    Iyad Husni Alshami

    2017-08-01

    Full Text Available The Global Positioning System demonstrates the significance of Location Based Services but it cannot be used indoors due to the lack of line of sight between satellites and receivers. Indoor Positioning Systems are needed to provide indoor Location Based Services. Wireless LAN fingerprints are one of the best choices for Indoor Positioning Systems because of their low cost, and high accuracy, however they have many drawbacks: creating radio maps is time consuming, the radio maps will become outdated with any environmental change, different mobile devices read the received signal strength (RSS differently, and peoples’ presence in LOS between access points and mobile device affects the RSS. This research proposes a new Adaptive Indoor Positioning System model (called DIPS based on: a dynamic radio map generator, RSS certainty technique and peoples’ presence effect integration for dynamic and multi-floor environments. Dynamic in our context refers to the effects of people and device heterogeneity. DIPS can achieve 98% and 92% positioning accuracy for floor and room positioning, and it achieves 1.2 m for point positioning error. RSS certainty enhanced the positioning accuracy for floor and room for different mobile devices by 11% and 9%. Then by considering the peoples’ presence effect, the error is reduced by 0.2 m. In comparison with other works, DIPS achieves better positioning without extra devices.

  9. Indoor environment and children's health: recent developments in chemical, biological, physical and social aspects.

    Science.gov (United States)

    Le Cann, Pierre; Bonvallot, Nathalie; Glorennec, Philippe; Deguen, Séverine; Goeury, Christophe; Le Bot, Barbara

    2011-12-01

    Much research is being carried out into indoor exposure to harmful agents. This review focused on the impact on children's health, taking a broad approach to the indoor environment and including chemical, microbial, physical and social aspects. Papers published from 2006 onwards were reviewed, with regards to scientific context. Most of publications dealt with chemical exposure. Apart from the ongoing issue of combustion by-products, most of these papers concerned semi volatile organic compounds (such as phthalates). These may be associated with neurotoxic, reprotoxic or respiratory effects and may, therefore, be of particular interest so far as children are concerned. In a lesser extent, volatile organic compounds (such as aldehydes) that have mainly respiratory effects are still studied. Assessing exposure to metals is still of concern, with increasing interest in bioaccessibility. Most of the papers on microbial exposure focused on respiratory tract infections, especially asthma linked to allergens and bio-aerosols. Physical exposure includes noise and electromagnetic fields, and articles dealt with the auditory and non auditory effects of noise. Articles on radiofrequency electromagnetic fields mainly concerned questions about non-thermal effects and papers on extremely low-frequency magnetic fields focused on the characterization of exposure. The impact of the indoor environment on children's health cannot be assessed merely by considering the effect of these different types of exposure: this review highlights new findings and also discusses the interactions between agents in indoor environments and also with social aspects. Copyright © 2011 Elsevier GmbH. All rights reserved.

  10. Perceived Indoor Environment and Occupants' Comfort in European "Modern" Office Buildings: The OFFICAIR Study.

    Science.gov (United States)

    Sakellaris, Ioannis A; Saraga, Dikaia E; Mandin, Corinne; Roda, Célina; Fossati, Serena; de Kluizenaar, Yvonne; Carrer, Paolo; Dimitroulopoulou, Sani; Mihucz, Victor G; Szigeti, Tamás; Hänninen, Otto; de Oliveira Fernandes, Eduardo; Bartzis, John G; Bluyssen, Philomena M

    2016-04-25

    Indoor environmental conditions (thermal, noise, light, and indoor air quality) may affect workers' comfort, and consequently their health and well-being, as well as their productivity. This study aimed to assess the relations between perceived indoor environment and occupants' comfort, and to examine the modifying effects of both personal and building characteristics. Within the framework of the European project OFFICAIR, a questionnaire survey was administered to 7441 workers in 167 "modern" office buildings in eight European countries (Finland, France, Greece, Hungary, Italy, The Netherlands, Portugal, and Spain). Occupants assessed indoor environmental quality (IEQ) using both crude IEQ items (satisfaction with thermal comfort, noise, light, and indoor air quality), and detailed items related to indoor environmental parameters (e.g., too hot/cold temperature, humid/dry air, noise inside/outside, natural/artificial light, odor) of their office environment. Ordinal logistic regression analyses were performed to assess the relations between perceived IEQ and occupants' comfort. The highest association with occupants' overall comfort was found for "noise", followed by "air quality", "light" and "thermal" satisfaction. Analysis of detailed parameters revealed that "noise inside the buildings" was highly associated with occupants' overall comfort. "Layout of the offices" was the next parameter highly associated with overall comfort. The relations between IEQ and comfort differed by personal characteristics (gender, age, and the Effort Reward Imbalance index), and building characteristics (office type and building's location). Workplace design should take into account both occupant and the building characteristics in order to provide healthier and more comfortable conditions to their occupants.

  11. Perceived Indoor Environment and Occupants’ Comfort in European “Modern” Office Buildings: The OFFICAIR Study

    Science.gov (United States)

    Sakellaris, Ioannis A.; Saraga, Dikaia E.; Mandin, Corinne; Roda, Célina; Fossati, Serena; de Kluizenaar, Yvonne; Carrer, Paolo; Dimitroulopoulou, Sani; Mihucz, Victor G.; Szigeti, Tamás; Hänninen, Otto; de Oliveira Fernandes, Eduardo; Bartzis, John G.; Bluyssen, Philomena M.

    2016-01-01

    Indoor environmental conditions (thermal, noise, light, and indoor air quality) may affect workers’ comfort, and consequently their health and well-being, as well as their productivity. This study aimed to assess the relations between perceived indoor environment and occupants’ comfort, and to examine the modifying effects of both personal and building characteristics. Within the framework of the European project OFFICAIR, a questionnaire survey was administered to 7441 workers in 167 “modern” office buildings in eight European countries (Finland, France, Greece, Hungary, Italy, The Netherlands, Portugal, and Spain). Occupants assessed indoor environmental quality (IEQ) using both crude IEQ items (satisfaction with thermal comfort, noise, light, and indoor air quality), and detailed items related to indoor environmental parameters (e.g., too hot/cold temperature, humid/dry air, noise inside/outside, natural/artificial light, odor) of their office environment. Ordinal logistic regression analyses were performed to assess the relations between perceived IEQ and occupants’ comfort. The highest association with occupants’ overall comfort was found for “noise”, followed by “air quality”, “light” and “thermal” satisfaction. Analysis of detailed parameters revealed that “noise inside the buildings” was highly associated with occupants’ overall comfort. “Layout of the offices” was the next parameter highly associated with overall comfort. The relations between IEQ and comfort differed by personal characteristics (gender, age, and the Effort Reward Imbalance index), and building characteristics (office type and building’s location). Workplace design should take into account both occupant and the building characteristics in order to provide healthier and more comfortable conditions to their occupants. PMID:27120608

  12. Perceived Indoor Environment and Occupants’ Comfort in European “Modern” Office Buildings: The OFFICAIR Study

    Directory of Open Access Journals (Sweden)

    Ioannis A. Sakellaris

    2016-04-01

    Full Text Available Indoor environmental conditions (thermal, noise, light, and indoor air quality may affect workers’ comfort, and consequently their health and well-being, as well as their productivity. This study aimed to assess the relations between perceived indoor environment and occupants’ comfort, and to examine the modifying effects of both personal and building characteristics. Within the framework of the European project OFFICAIR, a questionnaire survey was administered to 7441 workers in 167 “modern” office buildings in eight European countries (Finland, France, Greece, Hungary, Italy, The Netherlands, Portugal, and Spain. Occupants assessed indoor environmental quality (IEQ using both crude IEQ items (satisfaction with thermal comfort, noise, light, and indoor air quality, and detailed items related to indoor environmental parameters (e.g., too hot/cold temperature, humid/dry air, noise inside/outside, natural/artificial light, odor of their office environment. Ordinal logistic regression analyses were performed to assess the relations between perceived IEQ and occupants’ comfort. The highest association with occupants’ overall comfort was found for “noise”, followed by “air quality”, “light” and “thermal” satisfaction. Analysis of detailed parameters revealed that “noise inside the buildings” was highly associated with occupants’ overall comfort. “Layout of the offices” was the next parameter highly associated with overall comfort. The relations between IEQ and comfort differed by personal characteristics (gender, age, and the Effort Reward Imbalance index, and building characteristics (office type and building’s location. Workplace design should take into account both occupant and the building characteristics in order to provide healthier and more comfortable conditions to their occupants.

  13. The indoor environment of a modern museum building, the Sainsbury Centre for Visual Arts, Norwich, UK.

    Science.gov (United States)

    Brimblecombe, P; Blades, N; Camuffo, D; Sturaro, G; Valentino, A; Gysels, K; Van Grieken, R; Busse, H J; Kim, O; Ulrych, U; Wieser, M

    1999-09-01

    A multi-disciplinary approach was used to investigate the indoor environment of a modern museum building, and its suitability for the conservation of the collection therein. Climate, gaseous and particulate pollution and the concentrations of bacteria were measured in summer and winter campaigns. While the environment overall was found to be an acceptable one, a number of drawbacks were highlighted, the most serious of these being the large temperature and humidity fluctuations that occurred in the summer.

  14. Visual Localisation of Mobile Devices in an Indoor Environment under Network Delay Conditions

    OpenAIRE

    Fernández, Alberto Alonso; Fres, Omar Álvarez; Alonso, Ignacio González; Hu, Huosheng

    2011-01-01

    Current progresses in home automation and service robotic environment have highlighted the need to develop interoperability mechanisms that allow a standard communication between the two systems. During the development of the DHCompliant protocol, the problem of locating mobile devices in an indoor environment has been investigated. The communication of the device with the location service has been carried out to study the time delay that web services offer in front of the sockets. The import...

  15. A novel capacity controller for a three-evaporator air conditioning (TEAC) system for improved indoor humidity control

    International Nuclear Information System (INIS)

    Yan, Huaxia; Deng, Shiming; Chan, Ming-yin

    2016-01-01

    Highlights: • A novel capacity controller for TEAC systems for improved indoor humidity control is developed. • The novel controller was developed by integrating two previous control algorithms. • Experimental controllability tests were carried out. • Improved control over indoor humidity levels and higher energy efficiency can be achieved. - Abstract: Using a multi-evaporator air conditioning (MEAC) system to correctly control indoor air temperatures only in a multi-room application is already a challenging and difficult task, let alone the control of both indoor air temperature and humidity. This is because in an MEAC system, a number of indoor units are connected to a common condensing unit. Hence, the interferences among operation parameters of different indoor units would make the desired control of an MEAC system hard to realize. Limited capacity control algorithms for MEAC systems have been developed, with most of them focusing only on the control of indoor air temperature, and no previous studies involving control of indoor air humidity using MEAC systems can be identified. In this paper, the development of a novel capacity controller for a three-evaporator air conditioning (TEAC) system for improved indoor air humidity control is reported. The novel controller was developed by integrating two previous control algorithms for a dual-evaporator air conditioning system for temperature control and for a single-evaporator air conditioning system for improved indoor humidity control. Experimental controllability tests were carried out and the controllability test results showed that, with the novel controller, improved control over indoor humidity levels and better energy efficiency for a TEAC system could be obtained as compared to the traditional On–Off controllers extensively used by MEAC systems.

  16. Indoor Autonomous Control of a Two-Wheeled Inverted Pendulum Vehicle Using Ultra Wide Band Technology.

    Science.gov (United States)

    Xia, Dunzhu; Yao, Yanhong; Cheng, Limei

    2017-06-15

    In this paper, we aimed to achieve the indoor tracking control of a two-wheeled inverted pendulum (TWIP) vehicle. The attitude data are acquired from a low cost micro inertial measurement unit (IMU), and the ultra-wideband (UWB) technology is utilized to obtain an accurate estimation of the TWIP's position. We propose a dual-loop control method to realize the simultaneous balance and trajectory tracking control for the TWIP vehicle. A robust adaptive second-order sliding mode control (2-RASMC) method based on an improved super-twisting (STW) algorithm is investigated to obtain the control laws, followed by several simulations to verify its robustness. The outer loop controller is designed using the idea of backstepping. Moreover, three typical trajectories, including a circle, a trifolium and a hexagon, have been designed to prove the adaptability of the control combinations. Six different combinations of inner and outer loop control algorithms have been compared, and the characteristics of inner and outer loop algorithm combinations have been analyzed. Simulation results demonstrate its tracking performance and thus verify the validity of the proposed control methods. Trajectory tracking experiments in a real indoor environment have been performed using our experimental vehicle to further validate the feasibility of the proposed algorithm in practice.

  17. An Evaluation of Antifungal Agents for the Treatment of Fungal Contamination in Indoor Air Environments

    Directory of Open Access Journals (Sweden)

    Senthaamarai Rogawansamy

    2015-06-01

    Full Text Available Fungal contamination in indoor environments has been associated with adverse health effects for the inhabitants. Remediation of fungal contamination requires removal of the fungi present and modifying the indoor environment to become less favourable to growth.  This may include treatment of indoor environments with an antifungal agent to prevent future growth. However there are limited published data or advice on chemical agents suitable for indoor fungal remediation. The aim of this study was to assess the relative efficacies of five commercially available cleaning agents with published or anecdotal use for indoor fungal remediation. The five agents included two common multi-purpose industrial disinfectants (Cavicide® and Virkon®, 70% ethanol, vinegar (4.0%-4.2% acetic acid, and a plant-derived compound (tea tree (Melaleuca alternifolia oil tested in both a liquid and vapour form. Tea tree oil has recently generated interest for its antimicrobial efficacy in clinical settings, but has not been widely employed for fungal remediation. Each antifungal agent was assessed for fungal growth inhibition using a disc diffusion method against a representative species from two common fungal genera, (Aspergillus fumigatus and Penicillium chrysogenum, which were isolated from air samples and are commonly found in indoor air. Tea tree oil demonstrated the greatest inhibitory effect on the growth of both fungi, applied in either a liquid or vapour form. Cavicide® and Virkon® demonstrated similar, although less, growth inhibition of both genera. Vinegar (4.0%–4.2% acetic acid was found to only inhibit the growth of P. chrysogenum, while 70% ethanol was found to have no inhibitory effect on the growth of either fungi. There was a notable inhibition in sporulation, distinct from growth inhibition after exposure to tea tree oil, Virkon®, Cavicide® and vinegar. Results demonstrate that common cleaning and antifungal agents differ in their capacity to

  18. An evaluation of antifungal agents for the treatment of fungal contamination in indoor air environments.

    Science.gov (United States)

    Rogawansamy, Senthaamarai; Gaskin, Sharyn; Taylor, Michael; Pisaniello, Dino

    2015-06-02

    Fungal contamination in indoor environments has been associated with adverse health effects for the inhabitants. Remediation of fungal contamination requires removal of the fungi present and modifying the indoor environment to become less favourable to growth.  This may include treatment of indoor environments with an antifungal agent to prevent future growth. However there are limited published data or advice on chemical agents suitable for indoor fungal remediation. The aim of this study was to assess the relative efficacies of five commercially available cleaning agents with published or anecdotal use for indoor fungal remediation. The five agents included two common multi-purpose industrial disinfectants (Cavicide® and Virkon®), 70% ethanol, vinegar (4.0%-4.2% acetic acid), and a plant-derived compound (tea tree (Melaleuca alternifolia) oil) tested in both a liquid and vapour form. Tea tree oil has recently generated interest for its antimicrobial efficacy in clinical settings, but has not been widely employed for fungal remediation. Each antifungal agent was assessed for fungal growth inhibition using a disc diffusion method against a representative species from two common fungal genera, (Aspergillus fumigatus and Penicillium chrysogenum), which were isolated from air samples and are commonly found in indoor air. Tea tree oil demonstrated the greatest inhibitory effect on the growth of both fungi, applied in either a liquid or vapour form. Cavicide® and Virkon® demonstrated similar, although less, growth inhibition of both genera. Vinegar (4.0%-4.2% acetic acid) was found to only inhibit the growth of P. chrysogenum, while 70% ethanol was found to have no inhibitory effect on the growth of either fungi. There was a notable inhibition in sporulation, distinct from growth inhibition after exposure to tea tree oil, Virkon®, Cavicide® and vinegar. Results demonstrate that common cleaning and antifungal agents differ in their capacity to inhibit the growth

  19. CFD model of thermal and velocity conditions in a particular indoor environment

    Energy Technology Data Exchange (ETDEWEB)

    Mora Perez, Miguel; Lopez Patino, Gonzalo; Lopez Jimenez, P. Amparo [Hydraulic and Environmental Engineering Department, Universitat Politecnica de Valencia (Spain); Guillen Guillamon, Ignacio [Applied Physics Department, Universitat Politecnica de Valencia (Spain)

    2013-07-01

    The demand for maintaining high indoor environmental quality (IEQ) with the minimum energy consumption is rapidly increasing. In the recent years, several studies have been completed to investigate the impact of indoor environment factors on human comfort, health and energy efficiency. Therefore, the design of the thermal environment in any sort of room, specially offices, has huge economic consequences. In this paper, a particular analysis on the air temperature in a multi-task room environment is modeled, in order to represent the velocities and temperatures inside the room by using Computational Fluid Dynamics (CFD) techniques. This model will help to designers to analyze the thermal comfort regions inside the studied air volume and to visualize the whole temperatures inside the room, determining the effect of the fresh external incoming air in the internal air temperature.

  20. Three-Dimensional Microwave Imaging for Indoor Environments

    Science.gov (United States)

    Scott, Simon

    Microwave imaging involves the use of antenna arrays, operating at microwave and millimeter-wave frequencies, for capturing images of real-world objects. Typically, one or more antennas in the array illuminate the scene with a radio-frequency (RF) signal. Part of this signal reflects back to the other antennas, which record both the amplitude and phase of the reflected signal. These reflected RF signals are then processed to form an image of the scene. This work focuses on using planar antenna arrays, operating between 17 and 26 GHz, to capture three-dimensional images of people and other objects inside a room. Such an imaging system enables applications such as indoor positioning and tracking, health monitoring and hand gesture recognition. Microwave imaging techniques based on beamforming cannot be used for indoor imaging, as most objects lie within the array near-field. Therefore, the range-migration algorithm (RMA) is used instead, as it compensates for the curvature of the reflected wavefronts, hence enabling near-field imaging. It is also based on fast-Fourier transforms and is therefore computationally efficient. A number of novel RMA variants were developed to support a wider variety of antenna array configurations, as well as to generate 3-D velocity maps of objects moving around a room. The choice of antenna array configuration, microwave transceiver components and transmit power has a significant effect on both the energy consumed by the imaging system and the quality of the resulting images. A generic microwave imaging testbed was therefore built to characterize the effect of these antenna array parameters on image quality in the 20 GHz band. All variants of the RMA were compared and found to produce good quality three-dimensional images with transmit power levels as low as 1 muW. With an array size of 80x80 antennas, most of the imaging algorithms were able to image objects at 0.5 m range with 12.5 mm resolution, although some were only able to achieve

  1. Relative Performance of Indoor Vector Control Interventions in the Ifakara and the West African Experimental Huts.

    OpenAIRE

    Oumbouke, Welbeck A; Fongnikin, Augustin; Soukou, Koffi B; Moore, Sarah J; N'Guessan, Raphael

    2017-01-01

    Background West African and Ifakara experimental huts are used to evaluate indoor mosquito control interventions, including spatial repellents and insecticides. The two hut types differ in size and design, so a side-by-side comparison was performed to investigate the performance of indoor interventions in the two hut designs using standard entomological outcomes: relative indoor mosquito density (deterrence), exophily (induced exit), blood-feeding and mortality of mosquitoes. Methods Metoflut...

  2. A method for economic optimization of energy performance and indoor environment in the design of sustainable buildings

    DEFF Research Database (Denmark)

    Hansen, Sanne; Vanhoutteghem, Lies

    2012-01-01

    that takes into account the indoor thermal environment. By use of the criterion of cost of conserved energy implemented in a Microsoft Excel sheet, a cost optimal design according to a targeted energy frame can be found. The resulting indoor thermal environment is then evaluated based on parametric analysis...... that an economic design solution with good indoor environment can be identified. The example also shows that in order to ensure that buildings have low energy consumption, at minimum extra cost, more appropriate products and solutions will have to become available on the market at a competitive price....

  3. Indoor air quality in low-energy houses in the Netherlands: Does mechanical ventilation provide a healthy indoor environment?

    NARCIS (Netherlands)

    Balvers, J.R.; Boxem, G.; Wit, de M.H.; Strøm-Tejsen, P; Olesen, B.W.; Wargocki, P; Zukowska, D; Toftum, J

    2008-01-01

    Increasing environmental awareness has led to new, energy-efficient building standards such as the German Passivhaus-standard. This study was designed to investigate the indoor air quality (IAQ) of four different Dutch low-energy houses built according to this standard. Air flow, indoor air

  4. A hybrid stochastic approach for self-location of wireless sensors in indoor environments.

    Science.gov (United States)

    Lloret, Jaime; Tomas, Jesus; Garcia, Miguel; Canovas, Alejandro

    2009-01-01

    Indoor location systems, especially those using wireless sensor networks, are used in many application areas. While the need for these systems is widely proven, there is a clear lack of accuracy. Many of the implemented applications have high errors in their location estimation because of the issues arising in the indoor environment. Two different approaches had been proposed using WLAN location systems: on the one hand, the so-called deductive methods take into account the physical properties of signal propagation. These systems require a propagation model, an environment map, and the position of the radio-stations. On the other hand, the so-called inductive methods require a previous training phase where the system learns the received signal strength (RSS) in each location. This phase can be very time consuming. This paper proposes a new stochastic approach which is based on a combination of deductive and inductive methods whereby wireless sensors could determine their positions using WLAN technology inside a floor of a building. Our goal is to reduce the training phase in an indoor environment, but, without an loss of precision. Finally, we compare the measurements taken using our proposed method in a real environment with the measurements taken by other developed systems. Comparisons between the proposed system and other hybrid methods are also provided.

  5. A Hybrid Stochastic Approach for Self-Location of Wireless Sensors in Indoor Environments

    Directory of Open Access Journals (Sweden)

    Alejandro Canovas

    2009-05-01

    Full Text Available Indoor location systems, especially those using wireless sensor networks, are used in many application areas. While the need for these systems is widely proven, there is a clear lack of accuracy. Many of the implemented applications have high errors in their location estimation because of the issues arising in the indoor environment. Two different approaches had been proposed using WLAN location systems: on the one hand, the so-called deductive methods take into account the physical properties of signal propagation. These systems require a propagation model, an environment map, and the position of the radio-stations. On the other hand, the so-called inductive methods require a previous training phase where the system learns the received signal strength (RSS in each location. This phase can be very time consuming. This paper proposes a new stochastic approach which is based on a combination of deductive and inductive methods whereby wireless sensors could determine their positions using WLAN technology inside a floor of a building. Our goal is to reduce the training phase in an indoor environment, but, without an loss of precision. Finally, we compare the measurements taken using our proposed method in a real environment with the measurements taken by other developed systems. Comparisons between the proposed system and other hybrid methods are also provided.

  6. Human perception of indoor environment generated by chilled ceiling combined with mixing ventilation or localised chilled beam under cooling mode

    DEFF Research Database (Denmark)

    Bolashikov, Zhecho Dimitrov; Nygaard, Linette; Uth, Simon C.

    2014-01-01

    Experiments with 24 subjects were performed to study and compare the human perception of the indoor environment under summer conditions generated by a chilled ceiling combined with overhead mixing ventilation and localised chilled beam. The experiments were performed in an experimental chamber (4....../s and 16 0C. The localised chilled beam was installed over the workstation placed by the simulated window. During the experiment the subjects were delegated control over the primary flow rate supplied by the localised chilled beam. The whole exposure lasted 2 hours with 30 min of acclimatisation before...

  7. Environment control system

    International Nuclear Information System (INIS)

    Sammarone, D.G.

    1978-01-01

    Disclosed is a system for controlling the environment of an enclosed area in nuclear reactor installations. The system permits the changing of the environment from nitrogen to air, or from air to nitrogen, without the release of any radioactivity or process gas to the outside atmosphere

  8. Impact of Manually Controlled Solar Shades on Indoor Visual Comfort

    Directory of Open Access Journals (Sweden)

    Jian Yao

    2016-07-01

    Full Text Available Daylight plays a significant role in sustainable building design. The purpose of this paper was to investigate the impact of manual solar shades on indoor visual comfort. A developed stochastic model for manual solar shades was modeled in Building Controls Virtual Test Bed, which was coupled with EnergyPlus for co-simulation. Movable solar shades were compared with two unshaded windows. Results show that movable solar shades have more than half of the working hours with a comfortable illuminance level, which is about twice higher than low-e windows, with a less significant daylight illuminance fluctuation. For glare protection, movable solar shades increase comfortable visual conditions by about 20% compared to low-e windows. Moreover, the intolerable glare perception could be reduced by more than 20% for movable solar shades.

  9. [sup 210] Po as a long-term integrating radon indicator in the indoor environment

    Energy Technology Data Exchange (ETDEWEB)

    1992-01-01

    Exposure to radon (Rn-222) decay products in the indoor environment is suspected of being a significant lung cancer agent in many countries. But quantification of the contemporary lung cancer risk (i.e. probability) on an individual basis is not an easy task. Only past exposures are relevant and assessing individual exposures in retrospect is associated with large uncertainties, if possible at all. One way to extend the validity of contemporary measurements to past decades is to measure long-lived decay products of radon, the long-lived radon daughters. After our laboratory had exemplified the correlation between implanted Po-210 and the estimated radon exposures in six different dwellings, the US Department of Energy and the Swedish Radiation Protection Institute granted funds for a one-year study, [sup 210]Po as a Long-Term Integrating Radon Indicator in the Indoor Environment.'' In this report the work performed under these two contracts is reported.

  10. The importance of chemical components in cleaning agents for the indoor environment

    DEFF Research Database (Denmark)

    Vejrup, Karl Ventzel

    In order to evaluate the importance for the indoor environment of chemical compounds in cleaning agents, the emission of VOCs (Volatile Organic Compounds) from 10 selected cleaning agents and the content of LAS (Linear AlkanbenzeneSulfonate) in dust samples from 7 buildings were investigated.The...... of LAS between smooth floored corridors to carpeted offices, are apparently also of importance for the LAS content in individual rooms.The amounts of LAS found in the dust samples indicated that LAS may be of importance for the indoor environment, but inadequate knowledge about how low concentrations...... investigation of VOC emission from 10 selected cleaning agents showed that it was useful to classify the VOCs into two groups: nonpolar VOCs and polar VOCs.The nonpolar VOCs consisted of several hundred different compounds, mainly terpenes typically used as perfume in cleaning agents. The nonpolar VOC...

  11. An Empirical Path-Loss Model for Wireless Channels in Indoor Short-Range Office Environment

    Directory of Open Access Journals (Sweden)

    Ye Wang

    2012-01-01

    Full Text Available A novel empirical path-loss model for wireless indoor short-range office environment at 4.3–7.3 GHz band is presented. The model is developed based on the experimental datum sampled in 30 office rooms in both line of sight (LOS and non-LOS (NLOS scenarios. The model is characterized as the path loss to distance with a Gaussian random variable X due to the shadow fading by using linear regression. The path-loss exponent n is fitted by the frequency using power function and modeled as a frequency-dependent Gaussian variable as the standard deviation σ of X. The presented works should be available for the research of wireless channel characteristics under universal indoor short-distance environments in the Internet of Things (IOT.

  12. [sup 210] Po as a long-term integrating radon indicator in the indoor environment

    Energy Technology Data Exchange (ETDEWEB)

    1992-01-01

    Exposure to radon (Rn-222) decay products in the indoor environment is suspected of being a significant lung cancer agent in many countries. But quantification of the contemporary lung cancer risk (i.e. probability) on an individual basis is not an easy task. Only past exposures are relevant and assessing individual exposures in retrospect is associated with large uncertainties, if possible at all. One way to extend the validity of contemporary measurements to past decades is to measure long-lived decay products of radon, the long-lived radon daughters. After our laboratory had exemplified the correlation between implanted Po-210 and the estimated radon exposures in six different dwellings, the US Department of Energy and the Swedish Radiation Protection Institute granted funds for a one-year study, [sup 210]Po as a Long-Term Integrating Radon Indicator in the Indoor Environment.'' In this report the work performed under these two contracts is reported.

  13. Optimization of humidifying procedure in controlled environment for ...

    African Journals Online (AJOL)

    This study investigated mushroom cultivation in controlled indoor environment. For this, the environmental factors including humidity and temperature were controlled by humidifier and ventilation. Four ventilations were installed on tops to bring the air from inside to outside and four small ventilations were installed on side ...

  14. HyMoTrack: A Mobile AR Navigation System for Complex Indoor Environments.

    Science.gov (United States)

    Gerstweiler, Georg; Vonach, Emanuel; Kaufmann, Hannes

    2015-12-24

    Navigating in unknown big indoor environments with static 2D maps is a challenge, especially when time is a critical factor. In order to provide a mobile assistant, capable of supporting people while navigating in indoor locations, an accurate and reliable localization system is required in almost every corner of the building. We present a solution to this problem through a hybrid tracking system specifically designed for complex indoor spaces, which runs on mobile devices like smartphones or tablets. The developed algorithm only uses the available sensors built into standard mobile devices, especially the inertial sensors and the RGB camera. The combination of multiple optical tracking technologies, such as 2D natural features and features of more complex three-dimensional structures guarantees the robustness of the system. All processing is done locally and no network connection is needed. State-of-the-art indoor tracking approaches use mainly radio-frequency signals like Wi-Fi or Bluetooth for localizing a user. In contrast to these approaches, the main advantage of the developed system is the capability of delivering a continuous 3D position and orientation of the mobile device with centimeter accuracy. This makes it usable for localization and 3D augmentation purposes, e.g. navigation tasks or location-based information visualization.

  15. HyMoTrack: A Mobile AR Navigation System for Complex Indoor Environments

    Directory of Open Access Journals (Sweden)

    Georg Gerstweiler

    2015-12-01

    Full Text Available Navigating in unknown big indoor environments with static 2D maps is a challenge, especially when time is a critical factor. In order to provide a mobile assistant, capable of supporting people while navigating in indoor locations, an accurate and reliable localization system is required in almost every corner of the building. We present a solution to this problem through a hybrid tracking system specifically designed for complex indoor spaces, which runs on mobile devices like smartphones or tablets. The developed algorithm only uses the available sensors built into standard mobile devices, especially the inertial sensors and the RGB camera. The combination of multiple optical tracking technologies, such as 2D natural features and features of more complex three-dimensional structures guarantees the robustness of the system. All processing is done locally and no network connection is needed. State-of-the-art indoor tracking approaches use mainly radio-frequency signals like Wi-Fi or Bluetooth for localizing a user. In contrast to these approaches, the main advantage of the developed system is the capability of delivering a continuous 3D position and orientation of the mobile device with centimeter accuracy. This makes it usable for localization and 3D augmentation purposes, e.g. navigation tasks or location-based information visualization.

  16. Indoor air quality

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    Indoor Air Quality is rapidly becoming a major environmental concern because a significant amount of people spend a substantial amount of time in a variety of different indoor environments. Health effects from indoor pollutants fall into two categories: those that are experienced immediately after exposure and those that do not show up until years later. They are: radon, formaldehyde, asbestos, lead and household organic chemicals. The authors presented a source-by-source look at the most common indoor air pollutants, their potential health effects, and ways to reduce their levels in the home. There are three basic strategies to improve indoor air quality: one method is source control, another is through ventilation improvements, and the third is the utilization of some sort of mechanical device such as air cleaners

  17. Indoor air quality of environments used for physical exercise and sports practice: Systematic review.

    Science.gov (United States)

    Andrade, Alexandro; Dominski, Fábio Hech

    2018-01-15

    Systematic reviews have the potential to contribute substantially to environmental health and risk assessment. This study aimed to investigate indoor air quality of environments used for physical exercise and sports practice through a systematic review. The systematic review followed the PRISMA guidelines and was recorded in the PROSPERO registry (CRD42016036057). The search was performed using the SciELO, Science Direct, Scopus, LILACS, MEDLINE via PubMed, and SPORTDiscus databases, from their inception through April 2017. The search terms used in the databases were {air pollution" OR "air pollutants" OR "air quality"} AND {"physical exercise" OR "physical activity" OR "sport"}. The results of selected studies were divided into 5 categories for analysis: monitoring of air quality in the environment according to international guidelines, indoor-to-outdoor ratio (I/O), air quality during physical exercise, impact of air quality on health, and interventions to improve indoor air quality. Among 1281 studies screened, 34 satisfied the inclusion criteria. The monitoring of pollutants was conducted in 20 studies. CO and NO 2 were the most investigated pollutants, and guidelines were discussed in most studies. The I/O ratio was investigated in 12 studies, of which 9 showed a higher concentration of some pollutants in indoor rather than outdoor environments. Among the 34 studies selected, only 7 investigated the impact of indoor air pollution on human health. The population in most of these studies consisted of hockey players. Most studies conducted monitoring of pollutants in indoor environments used for physical exercise and sports practice. The earliest studies were conducted in ice skating rinks and the most recent evaluated gymnasiums, fitness centers, and sports centers. The CO, particulate matter, and NO 2 concentrations were the most investigated and have the longest history of investigation. These pollutants were within the limits established by guidelines in most

  18. Fast, Automated, Scalable Generation of Textured 3D Models of Indoor Environments

    Science.gov (United States)

    2014-12-18

    throughs of environments, gaming entertainment, augmented reality , indoor navigation, and energy simulation analysis. These applications rely on the...models are used in virtual reality , gaming, navigation, and simulation applica- tions. State-of-the-art scanning produces accurate point-clouds of...meshes that remove furniture and other temporary objects. We propose a method to texture-map these models from captured camera imagery to produce

  19. Vision-Based System for Human Detection and Tracking in Indoor Environment

    OpenAIRE

    Benezeth , Yannick; Emile , Bruno; Laurent , Hélène; Rosenberger , Christophe

    2010-01-01

    International audience; In this paper, we propose a vision-based system for human detection and tracking in indoor environment using a static camera. The proposed method is based on object recognition in still images combined with methods using temporal information from the video. Doing that, we improve the performance of the overall system and reduce the task complexity. We first use background subtraction to limit the search space of the classifier. The segmentation is realized by modeling ...

  20. RSSI-Based Distance Estimation Framework Using a Kalman Filter for Sustainable Indoor Computing Environments

    Directory of Open Access Journals (Sweden)

    Yunsick Sung

    2016-11-01

    Full Text Available Given that location information is the key to providing a variety of services in sustainable indoor computing environments, it is required to obtain accurate locations. Locations can be estimated by three distances from three fixed points. Therefore, if the distance between two points can be measured or estimated accurately, the location in indoor environments can be estimated. To increase the accuracy of the measured distance, noise filtering, signal revision, and distance estimation processes are generally performed. This paper proposes a novel framework for estimating the distance between a beacon and an access point (AP in a sustainable indoor computing environment. Diverse types of received strength signal indications (RSSIs are used for WiFi, Bluetooth, and radio signals, and the proposed distance estimation framework is unique in that it is independent of the specific wireless signal involved, being based on the Bluetooth signal of the beacon. Generally, RSSI measurement, noise filtering, and revision are required for distance estimation using RSSIs. The employed RSSIs are first measured from an AP, with multiple APs sometimes used to increase the accuracy of the distance estimation. Owing to the inevitable presence of noise in the measured RSSIs, the application of noise filtering is essential, and further revision is used to address the inaccuracy and instability that characterizes RSSIs measured in an indoor environment. The revised RSSIs are then used to estimate the distance. The proposed distance estimation framework uses one AP to measure the RSSIs, a Kalman filter to eliminate noise, and a log-distance path loss model to revise the measured RSSIs. In the experimental implementation of the framework, both a RSSI filter and a Kalman filter were respectively used for noise elimination to comparatively evaluate the performance of the latter for the specific application. The Kalman filter was found to reduce the accumulated errors by 8

  1. Development of an Indoor Airflow Energy Harvesting System for Building Environment Monitoring

    OpenAIRE

    Fei Fei; Shengli Zhou; John D. Mai; Wen Jung Li

    2014-01-01

    Wireless sensor networks (WSNs) have been widely used for intelligent building management applications. Typically, indoor environment parameters such as illumination, temperature, humidity and air quality are monitored and adjusted by an intelligent building management system. However, owing to the short life-span of the batteries used at the sensor nodes, the maintenance of such systems has been labor-intensive and time-consuming. This paper discusses a battery-less self-powering system that...

  2. Building certification schemes and the quality of indoor environment

    DEFF Research Database (Denmark)

    Da Silva, Nuno Alexandre Faria

    Building certification schemes create a new standard for the built environment reflecting the growing environmental consciousness and the need for “green buildings”. They are expected to signify an outstanding quality and excellence. Buildings, which receive a high degree of certification......, providing information on the performance of building certification schemes in relation to IEQ and ratings of building occupants. Then, information was collected on IEQ in existing office buildings certified as green buildings with particular focus on the work performance indicators, acute health symptoms......, and perceptions and comfort. Information on IEQ in the existing buildings was collected through field campaigns. They comprised measurements in 6 office buildings in Singapore certified using the Green Mark (GM) Certification Scheme. The measurements were additionally carried out in 6 office buildings...

  3. Determination of fluorotelomer alcohols in selected consumer products and preliminary investigation of their fate in the indoor environment

    Science.gov (United States)

    The U.S. Environmental Protection Agency (EPA) has established an ongoing effort to identify the major perfluorocarboxylic acid (PFCA) sources in nonoccupational indoor environments and characterize their transport and fate. This study determined the concentrations of perfluorote...

  4. Composition of heavy metals and airborne fibers in the indoor environment of a building during renovation.

    Science.gov (United States)

    Latif, Mohd Talib; Baharudin, Nor Hafizah; Velayutham, Puvaneswary; Awang, Normah; Hamdan, Harimah; Mohamad, Ruqyyah; Mokhtar, Mazlin B

    2011-10-01

    The renovation of a building will certainly affect the quality of air in the vicinity of where associated activities were undertaken, this includes the quality of air inside the building. Indoor air pollutants such as particulate matter, heavy metals, and fine fibers are likely to be emitted during renovation work. This study was conducted to determine the concentration of heavy metals, asbestos and suspended particulates in the Biology Building, at the Universiti Kebangsaan, Malaysia (UKM). Renovation activities were carried out widely in the laboratories which were located in this building. A low-volume sampler was used to collect suspended particulate matter of a diameter size less than 10 μm (PM₁₀) and an air sampling pump, fitted with a cellulose ester membrane filter, were used for asbestos sampling. Dust was collected using a small brush and scope. The concentration of heavy metals was determined through the use of inductively coupled plasma-mass spectroscopy and the fibers were counted through a phase contrast microscope. The concentrations of PM₁₀ recorded in the building during renovation action (ranging from 166 to 542 μg m⁻³) were higher than the value set by the Department of Safety and Health for respirable dust (150 μg m⁻³). Additionally, they were higher than the value of PM₁₀ recorded in indoor environments from other studies. The composition of heavy metals in PM₁₀ and indoor dust were found to be dominated by Zn and results also showed that the concentration of heavy metals in indoor dust and PM₁₀ in this study was higher than levels recorded in other similar studies. The asbestos concentration was 0.0038 ± 0.0011 fibers/cc. This was lower than the value set by the Malaysian Department of Occupational, Safety and Health (DOSH) regulations of 0.1 fibers/cc, but higher than the background value usually recorded in indoor environments. This study strongly suggests that renovation issues need to be considered seriously

  5. Theoretical evaluation of indoor radon control using a carbon adsorption system

    International Nuclear Information System (INIS)

    Bocanegra, R.; Hopke, P.K.

    1989-01-01

    The conceptual framework for a carbon-based adsorption system for the control of indoor radon is presented. Based on the adsorptivity of typically available activated carbons, it is shown theoretically that carbon bed adsorbers can be effective in lowering indoor radon levels particularly when the area of radon ingress (the basement) has a relatively low exchange rate with the rest of the house

  6. HVAC SYSTEMS AS A TOOL IN CONTROLLING INDOOR AIR QUALITY: A LITERATURE REVIEW

    Science.gov (United States)

    The report gives results of a review of literature on the use of heating, ventilating, and air-conditioning (HVAC) systems to control indoor air quality (IAQ). Although significant progress has been made in reducing the energy consumption of HVAC systems, their effect on indoor a...

  7. Robust free-space optical communication for indoor information environment

    Science.gov (United States)

    Nakada, Toyohisa; Itoh, Hideo; Kunifuji, Susumu; Nakashima, Hideyuki

    2003-10-01

    The purpose of our study is to establish a robust communication, while keeping security and privacy, between a handheld communicator and the surrounding information environment. From the viewpoint of low power consumption, we have been developing a reflectivity modulating communication module composed of a liquid crystal light modulator and a corner-reflecting mirror sheet. We installed a corner-reflecting sheet instead of light scattering sheet in a handheld videogame machine with a display screen with a reflection-type liquid crystal. Infrared (IR) LED illuminator attached next to the IR camera of a base station illuminates all the room, and the terminal send their data to the base station by switching ON and OFF of the reflected IR beam. Intensity of reflected light differs with the position and the direction of the terminal, and sometimes the intensity of OFF signal at a certain condition is brighter than that of ON signal at another condition. To improve the communication quality, use of machine learning technique is a possibility of the solution. In this paper, we compare various machine learning techniques for the purpose of free space optical communication, and propose a new algorithm that improves the robustness of the data link. Evaluation using an actual free-space communication system is also described.

  8. Thoron (220Rn) in the indoor atmospheric environment

    International Nuclear Information System (INIS)

    Ramachandran, T.V.

    2006-01-01

    Naturally occurring background radiation is a topic, which has evoked curiosity and concern between the scientist and layman alike in recent years due to the shift in focus of health effects due to exposure of radiation from acute high level to chronic low level. Many locations around the world have higher levels of natural background radiation due to elevated levels of primordial radio nuclides in the soil and their decay products like radon ( 222 Rn), and thoron ( 220 Rn) in the environment. Of late, technologically enhanced naturally occurring radioactive material has also contributed to the burden of background radiation. It has been estimated that inhalation of 222 Rn, 2 20 Rn and their short lived progenies contribute more than 54% of the total natural background radiation dose received by the general population. In the Indian context, in an earlier national survey, the external gamma radiation dose rates have been more or less well mapped using thermo luminescent dosimeters covering more than 214 locations, which has yielded a national average of 775 mGy/y. Of this, nearly 48.7% contribution of the dose rate is from 40 K and the rest from the uranium (33.6%) and thorium (17.7%) series. A good database pertaining to the country wide levels of uranium, thorium and potassium in geological materials also exists. Thus, there exists a good database on the total external gamma radiation level across the country. Since the contribution from inhalation of 222 Rn, 220 Rn and their short lived progenies contributes more than 54% of the total background radiation dose, it was necessary to supplement the external component with inhalation component. This component is not adequately estimated for the country so far on national level. With this in mind, a national survey has been executed by this center involving a large number of universities and other allied research institutions from different parts of the country for the estimation of inhalation component of the dose

  9. Robustness of Visual Place Cells in Dynamic Indoor and Outdoor Environment

    Directory of Open Access Journals (Sweden)

    C. Giovannangeli

    2006-06-01

    Full Text Available In this paper, a model of visual place cells (PCs based on precise neurobiological data is presented. The robustness of the model in real indoor and outdoor environments is tested. Results show that the interplay between neurobiological modelling and robotic experiments can promote the understanding of the neural structures and the achievement of robust robot navigation algorithms. Short Term Memory (STM, soft competition and sparse coding are important for both landmark identification and computation of PC activities. The extension of the paradigm to outdoor environments has confirmed the robustness of the vision-based model and pointed to improvements in order to further foster its performance.

  10. Indoor environment and installations in nursing home; Binnenmilieu en installaties in het verpleeghuis

    Energy Technology Data Exchange (ETDEWEB)

    Van Hoof, J.; Kort, H.S.M.; Duijnstee, M.S.H. [Kenniscentrum Innovatie van Zorgverlening, Faculteit Gezondheidszorg, Hogeschool Utrecht, Utrecht (Netherlands); Hensen, J.L.M.; Rutten, P.G.S. [Unit Building Physics and Systems, Faculteit Bouwkunde, Technische Universiteit Eindhoven, Eindhoven (Netherlands)

    2010-04-15

    The majority of nursing home residents are older adults with dementia. People with dementia may have an altered sensitivity for indoor environmental conditions, which can induce problematic behaviour with burdensome symptoms. This paper provides an overview of the ageing of senses and needs of older adults with dementia in relation to the indoor environment. Results can help designers and building services engineers to create optima[ environmental conditions in nursing homes. [Dutch] De verpleeghuizen in Nederland bieden zorg en verblijf aan ouderen met een intensieve zorgvraag. Het grote aantal installaties dat in deze woonvorm aanwezig is dient zo te worden ontworpen en geinstalleerd dat deze optimaal comfort bieden aan bewoners en zorgprofessionals. Ouderen met dementie vormen de grootste groep bewoners en hebben zeer specifieke behoeften voor het binnenmilieu. Door hiervan uit te gaan bij ontwerp en installatie, ontstaat een verpleeghuis dat ten dienste staat van alle bewoners en overige gebouwgebruikers.

  11. Development of a field measurement methodology for studying the thermal indoor environment in hybrid GEOTABS buildings

    DEFF Research Database (Denmark)

    Kazanci, Ongun Berk; Khovalyg, Dolaana; Olesen, Bjarne W.

    2018-01-01

    buildings. The three demonstration buildings were an office building in Luxembourg, an elderly care home in Belgium, and an elementary school in Czech Republic. All of these buildings are equipped with hybrid GEOTABS systems; however, they vary in size and function, which requires a unique measurement...... methodology for studying them. These buildings already have advanced Building Management Systems (BMS); however, a more detailed measurement plan was needed for the purposes of the project to document the current performance of these systems regarding thermal indoor environment and energy performance......, and to be able to document the improvements after the implementation of the MPC. This study provides the details of the developed field measurement methodology for each of these buildings to study the indoor environmental quality (IEQ) in details. The developed measurement methodology can be applied to other...

  12. Spatio-Temporal Analysis of Human Activities in Indoor Environments through Mobile Sensing

    DEFF Research Database (Denmark)

    Prentow, Thor Siiger

    with the intuition and personal experience of the planners. Lack of real-time information on task execution has made it difficult to adapt to changes in the schedules, such as delays or suddenly occurring urgent tasks. The recent advances in methods and devices for mobile sensing provides opportunities...... methods for spatio-temporal analysis of human activities in indoor environments based on mobile sensing. The methods aim to improve scheduling and facility utilization by providing information on the used route networks, transportation modes, travel times, and the flow of people through buildings....... The methods are based on large-scale real-time indoor positioning through the use of existing WiFi infrastructures, which allows for easy deployment even in very large building complexes. The methods are designed for real-time operation, which enables them to detect and adjust to changes as they occur...

  13. Assessment of polycyclic aromatic hydrocarbons in indoor and outdoor air of preschool environments (3–5 years old children)

    International Nuclear Information System (INIS)

    Oliveira, Marta; Slezakova, Klara; Delerue-Matos, Cristina; Pereira, Maria do Carmo; Morais, Simone

    2016-01-01

    This work characterizes levels of polycyclic aromatic hydrocarbons (PAHs) in indoor and outdoor air of preschool environments, and assesses the respective risks for 3–5-years old children. Eighteen gaseous and particulate (PM_1 and PM_2_._5) PAHs were collected indoors and outdoors during 63 days at preschools in Portugal. Gaseous PAHs accounted for 94–98% of total concentration (Σ_P_A_H_s). PAHs with 5–6 rings were predominantly found in PM_1 (54–74% particulate Σ_P_A_H_s). Lighter PAHs originated mainly from indoor sources whereas congeners with 4–6 rings resulted mostly from outdoor emissions penetration (motor vehicle, fuel burning). Total cancer risks of children were negligible according to USEPA, but exceeded (8–13 times) WHO health-based guideline. Carcinogenic risks due to indoor exposure were higher than for outdoors (4–18 times). - Highlights: • Lighter PAHs originate from indoor sources, 4–6 rings PAHs result from outdoors. • Gaseous PAHs account for the majority of PAH content in indoor air of preschools. • Lifetime lung cancer risk values exceed WHO health-based guideline level of 10"−"5. • Carcinogenic risks due to preschool indoor exposure are higher than for outdoors. - This work fills gap providing information on levels, phase distribution (gas, PM_1, PM_2_._5) and risks of polycyclic aromatic hydrocarbons in indoor and outdoor air of preschool settings.

  14. Improving indoor air quality for poor families: a controlled experiment in Bangladesh.

    Science.gov (United States)

    Dasgupta, S; Wheeler, D; Huq, M; Khaliquzzaman, M

    2009-02-01

    The World Health Organization's 2004 Global and Regional Burden of Disease Report estimates that acute respiratory infections from indoor air pollution (pollution from burning wood, animal dung, and other bio-fuels) kill a million children annually in developing countries, inflicting a particularly heavy toll on poor families in South Asia and Africa. This paper reports on an experiment that studied the use of different fuels in conjunction with different combinations of construction materials, space configurations, cooking locations, and household ventilation practices (use of doors and windows) as potentially-important determinants of indoor air pollution. Results from controlled experiments in Bangladesh were analyzed to test whether changes in these determinants can have significant effects on indoor air pollution. Analysis of the data shows, for example, that pollution from the cooking area is transported into living spaces rapidly and completely. Furthermore, it is important to factor in the interaction between outdoor and indoor air pollution. Hence, the optimal cooking location should take 'seasonality' in account. Among fuels, seasonal conditions seem to affect the relative severity of pollution from wood, dung, and other biomass fuels. However, there is no ambiguity about their collective impact. All are far dirtier than clean (LPG and Kerosene) fuels. The analysis concludes that if cooking with clean fuels is not possible, then building the kitchen with permeable construction material and providing proper ventilation in cooking areas will yield a better indoor health environment. Several village-level measures could significantly reduce IAP exposure in Bangladesh. All would require arrangements and the assert of male heads-of-household: negotiated bulk purchases of higher cost, cleaner fuels; purchase of more fuel-efficient stoves; peripheral location of cooking facilities; building the kitchen with permeable construction material; rotation of women in

  15. Geologic controls on indoor radon in the Pacific Northwest

    International Nuclear Information System (INIS)

    Otton, J.K.; Duval, J.S.

    1990-01-01

    This paper reports on comparisons of average indoor radon levels, soil radium content (derived from aerial gamma-ray data), and soil characteristics for selected townships in Washington, Oregon, and Idaho which show that: soil radium content provides a first-order estimate of the relative amounts of indoor radon where soils are either of low to moderate intrinsic permeability or of permeability reduced by high moisture; in drier parts of the study area (east of the Cascade Mountains), unusually high average indoor radon levels are almost all characterized by soils that have high effective permeabilities (greater than 20 inches per hour), based on available country soil descriptions; and in the wetter parts of the study area (west of the Cascade Mountains), townships with unusually high indoor radon levels are characterized by steeply sloped soils

  16. Controlled Environment Specimen Transfer

    DEFF Research Database (Denmark)

    Damsgaard, Christian Danvad; Zandbergen, Henny W.; Hansen, Thomas Willum

    2014-01-01

    an environmental transmission electron microscope to an in situ X-ray diffractometer through a dedicated transmission electron microscope specimen transfer holder, capable of sealing the specimen in a gaseous environment at elevated temperatures. Two catalyst material systems have been investigated; Cu/ZnO/Al2O3...... transferred in a reactive environment to the environmental transmission electron microscope where further analysis on the local scale were conducted. The Co/Al2O3 catalyst was reduced in the environmental microscope and successfully kept reduced outside the microscope in a reactive environment. The in situ......Specimen transfer under controlled environment conditions, such as temperature, pressure, and gas composition, is necessary to conduct successive complementary in situ characterization of materials sensitive to ambient conditions. The in situ transfer concept is introduced by linking...

  17. Healthy environment--indoor air quality of Brazilian elementary schools nearby petrochemical industry.

    Science.gov (United States)

    Godoi, Ricardo H M; Godoi, Ana F L; Gonçalves Junior, Sérgio J; Paralovo, Sarah L; Borillo, Guilherme C; Gonçalves Gregório Barbosa, Cybelli; Arantes, Manoela G; Charello, Renata C; Rosário Filho, Nelson A; Grassi, Marco T; Yamamoto, Carlos I; Potgieter-Vermaak, Sanja; Rotondo, Giuliana G; De Wael, Karolien; van Grieken, Rene

    2013-10-01

    The mitigation of pollution released to the environment originating from the industrial sector has been the aim of all policy-makers and its importance is evident if the adverse health effects on the world population are considered. Although this concern is controversial, petroleum refinery has been linked to some adverse health effects for people living nearby. Apart from home, school is the most important indoor environment for children and there is increasing concern about the school environment and its impact on health, also in developing countries where the prevalence of pollution is higher. As most of the children spend more than 40% of their time in schools, it is critical to evaluate the pollution level in such environment. In the metropolitan region of Curitiba, South Brazil, five schools nearby industries and highways with high density traffic, were selected to characterize the aerosol and gaseous compounds indoor and outdoor of the classrooms, during 2009-2011. Size segregated aerosol samples were collected for analyses of bulk and single particle elemental profiles. They were analyzed by electron probe X-ray micro-analysis (EPXMA), and by energy-dispersive X-ray fluorescence (EDXRF), to investigate the elemental composition of individual particles and bulk samples. The concentrations of benzene, toluene, ethylbenzene, and xylene (BTEX); NO2; SO2; acetic acid; and formic acid were assessed indoor and outdoor using passive diffusion tubes. BTEX were analyzed by GC-MS and other collected gasses by ion chromatography. Individual exposition of BTEX was assessed by personal passive diffusion tubes. Results are interpreted separately and as a whole with the specific aim of identifying compounds that could affect the health of the scholars. In view of the chemical composition and size distribution of the aerosol particles, local deposition efficiencies in the children's respiratory systems were calculated, revealing the deposition of particles at extrathoracic

  18. Health Effects of Indoor Air Pollutants and their Mitigation and Control (invited paper)

    International Nuclear Information System (INIS)

    Maroni, M.

    1998-01-01

    The nature of chemical, biological and physical contaminants present in indoor air, their sources, and the health effects they cause are reviewed. Among the physical agents, the interaction between tobacco smoke and radon is discussed. Control and improvement of indoor air quality can be achieved combining the use of two main strategies: proper design and construction of buildings, and control of indoor air pollution through source control, ventilation, air cleaning, exposure control, or a combination of them. A number of control measures primarily targeted to pollutants other than radon can also be particularly effective for radon. On the other hand, measures primarily targeted to radon containment can also be beneficial for other pollutants. Effective programmes on indoor air improvement are urgently needed to benefit the health, comfort and productivity of our communities. (author)

  19. PARAMETER ESTIMATION AND MODEL SELECTION FOR INDOOR ENVIRONMENTS BASED ON SPARSE OBSERVATIONS

    Directory of Open Access Journals (Sweden)

    Y. Dehbi

    2017-09-01

    Full Text Available This paper presents a novel method for the parameter estimation and model selection for the reconstruction of indoor environments based on sparse observations. While most approaches for the reconstruction of indoor models rely on dense observations, we predict scenes of the interior with high accuracy in the absence of indoor measurements. We use a model-based top-down approach and incorporate strong but profound prior knowledge. The latter includes probability density functions for model parameters and sparse observations such as room areas and the building footprint. The floorplan model is characterized by linear and bi-linear relations with discrete and continuous parameters. We focus on the stochastic estimation of model parameters based on a topological model derived by combinatorial reasoning in a first step. A Gauss-Markov model is applied for estimation and simulation of the model parameters. Symmetries are represented and exploited during the estimation process. Background knowledge as well as observations are incorporated in a maximum likelihood estimation and model selection is performed with AIC/BIC. The likelihood is also used for the detection and correction of potential errors in the topological model. Estimation results are presented and discussed.

  20. Airborne spread of expiratory droplet nuclei between the occupants of indoor environments: A review.

    Science.gov (United States)

    Ai, Z T; Melikov, A K

    2018-07-01

    This article reviews past studies of airborne transmission between occupants in indoor environments, focusing on the spread of expiratory droplet nuclei from mouth/nose to mouth/nose for non-specific diseases. Special attention is paid to summarizing what is known about the influential factors, the inappropriate simplifications of the thermofluid boundary conditions of thermal manikins, the challenges facing the available experimental techniques, and the limitations of available evaluation methods. Secondary issues are highlighted, and some new ways to improve our understanding of airborne transmission indoors are provided. The characteristics of airborne spread of expiratory droplet nuclei between occupants, which are influenced correlatively by both environmental and personal factors, were widely revealed under steady-state conditions. Owing to the different boundary conditions used, some inconsistent findings on specific influential factors have been published. The available instrumentation was too slow to provide accurate concentration profiles for time-dependent evaluations of events with obvious time characteristics, while computational fluid dynamics (CFD) studies were mainly performed in the framework of inherently steady Reynolds-averaged Navier-Stokes modeling. Future research needs in 3 areas are identified: the importance of the direction of indoor airflow patterns, the dynamics of airborne transmission, and the application of CFD simulations. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Parameter Estimation and Model Selection for Indoor Environments Based on Sparse Observations

    Science.gov (United States)

    Dehbi, Y.; Loch-Dehbi, S.; Plümer, L.

    2017-09-01

    This paper presents a novel method for the parameter estimation and model selection for the reconstruction of indoor environments based on sparse observations. While most approaches for the reconstruction of indoor models rely on dense observations, we predict scenes of the interior with high accuracy in the absence of indoor measurements. We use a model-based top-down approach and incorporate strong but profound prior knowledge. The latter includes probability density functions for model parameters and sparse observations such as room areas and the building footprint. The floorplan model is characterized by linear and bi-linear relations with discrete and continuous parameters. We focus on the stochastic estimation of model parameters based on a topological model derived by combinatorial reasoning in a first step. A Gauss-Markov model is applied for estimation and simulation of the model parameters. Symmetries are represented and exploited during the estimation process. Background knowledge as well as observations are incorporated in a maximum likelihood estimation and model selection is performed with AIC/BIC. The likelihood is also used for the detection and correction of potential errors in the topological model. Estimation results are presented and discussed.

  2. Assessing indoor air quality of school environments: transplanted lichen Pseudovernia furfuracea as a new tool for biomonitoring and bioaccumulation.

    Science.gov (United States)

    Protano, Carmela; Owczarek, Malgorzata; Antonucci, Arianna; Guidotti, Maurizio; Vitali, Matteo

    2017-07-01

    The aim of this research is to evaluate the ability of transplanted lichen Pseudovernia (P). furfuracea to biomonitor and bioaccumulate in urban indoor environments. The elements As, Cd, Cr, Cu, Hg, Ni and Pb and 12 selected polycyclic aromatic hydrocarbons (PAHs) were used to assess P. furfuracea as a biomonitoring tool for the indoor air quality of school environments. To achieve this purpose, lichen samples were exposed for 2 months in the outdoor and indoor environments of five school settings located in urban and rural areas. The results demonstrated that transplanted lichen P. furfuracea is a suitable biomonitoring tool for metals and PAHs in indoor settings and can discriminate between different levels of air pollution related to urbanisation and indoor conditions, such as those characterised by school environments. A transplanted lichen biomonitoring strategy is cost-effective, "green", educational for attending children and less "invasive" than traditional air sampling methods. The feasibility of indoor monitoring by P. furfuracea is a relevant finding and could be a key tool to improve air quality monitoring programmes in school scenarios and thus focus on health prevention interventions for children, who are one of the most susceptible groups in the population.

  3. Radon in the life environment and its countermeasures of prevention and control

    International Nuclear Information System (INIS)

    Li Zhenyuan; Zhang Shucheng

    2004-01-01

    Radon and its daughters are a primary component for human body received total natural radiation. They will hurt human body, even fall ill when human body is over-received radiation permitted in the life environment, especially indoors. The paper introduces mainly production mechanism of the radon and its daughters at indoor environment, the live environment investigation and monitoring technology, and effect factors on the radon concentration and distribution, as well as protection and control countermeasures for radon. (authors)

  4. Indoor Chemistry

    DEFF Research Database (Denmark)

    Weschler, Charles J.; Carslaw, Nicola

    2018-01-01

    This review aims to encapsulate the importance, ubiquity, and complexity of indoor chemistry. We discuss the many sources of indoor air pollutants and summarize their chemical reactions in the air and on surfaces. We also summarize some of the known impacts of human occupants, who act as sources...... and sinks of indoor chemicals, and whose activities (e.g., cooking, cleaning, smoking) can lead to extremely high pollutant concentrations. As we begin to use increasingly sensitive and selective instrumentation indoors, we are learning more about chemistry in this relatively understudied environment....

  5. Predictive control techniques for energy and indoor environmental quality management in buildings

    Energy Technology Data Exchange (ETDEWEB)

    Kolokotsa, D. [Technological Educational Institute of Crete, Department of Natural Resources and Environment, 3, Romanou str., 73133, Hania, Crete (Greece); Pouliezos, A. [Technical University of Crete, Department of Production Engineering and Management, University Campus, Kounoupidiana, 73100 Hania (Greece); Stavrakakis, G.; Lazos, C. [Technical University of Crete, Department of Electronics and Computer Engineering, University Campus, Kounoupidiana, 73100 Hania (Greece)

    2009-09-15

    The aim of the present paper is to present a model-based predictive controller, combined with a Building Energy Management System (BEMS). The overall system predicts the indoor environmental conditions of a specific building and selects the most appropriate actions so as to reach the set points and contribute to the indoor environmental quality by minimizing energy costs. The controller is tested using a BEMS installation in Hania, Crete, Greece. (author)

  6. An Indoor Location-Based Control System Using Bluetooth Beacons for IoT Systems

    OpenAIRE

    Jun-Ho Huh; Kyungryong Seo

    2017-01-01

    The indoor location-based control system estimates the indoor position of a user to provide the service he/she requires. The major elements involved in the system are the localization server, service-provision client, user application positioning technology. The localization server controls access of terminal devices (e.g., Smart Phones and other wireless devices) to determine their locations within a specified space first and then the service-provision client initiates required services such...

  7. Validation of Experimental whole-body SAR Assessment Method in a Complex Indoor Environment

    DEFF Research Database (Denmark)

    Bamba, Aliou; Joseph, Wout; Vermeeren, Gunter

    2012-01-01

    Assessing experimentally the whole-body specific absorption rate (SARwb) in a complex indoor environment is very challenging. An experimental method based on room electromagnetics theory (accounting only the Line-Of-Sight as specular path) to assess the whole-body SAR is validated by numerical...... of the proposed method is that it allows discarding the computation burden because it does not use any discretizations. Results show good agreement between measurement and computation at 2.8 GHz, as long as the plane wave assumption is valid, i.e., for high distances from the transmitter. Relative deviations 0...

  8. Two-Stage Maximum Likelihood Estimation (TSMLE for MT-CDMA Signals in the Indoor Environment

    Directory of Open Access Journals (Sweden)

    Sesay Abu B

    2004-01-01

    Full Text Available This paper proposes a two-stage maximum likelihood estimation (TSMLE technique suited for multitone code division multiple access (MT-CDMA system. Here, an analytical framework is presented in the indoor environment for determining the average bit error rate (BER of the system, over Rayleigh and Ricean fading channels. The analytical model is derived for quadrature phase shift keying (QPSK modulation technique by taking into account the number of tones, signal bandwidth (BW, bit rate, and transmission power. Numerical results are presented to validate the analysis, and to justify the approximations made therein. Moreover, these results are shown to agree completely with those obtained by simulation.

  9. Transport of gaseous pollutants around a human body in quiescent indoor environment

    DEFF Research Database (Denmark)

    Licina, Dusan; Melikov, Arsen Krikor; Mioduszewski, Pawel

    2014-01-01

    (CBL) to transport the pollution in quiescent indoor environment. A human body is resembled by a thermal manikin with a body shape and surface temperature distribution of a real person. The objective of the study is to examine the impact of the pollutant location around the human body on the pollution...... concentration levels in the breathing zone. The results show that the location of the pollution source has a considerable influence of the breathing zone concentrations. This is contributed to the human CBL, as it pulls the pollution emitted close to the human body and transports it to the breathing zone...... the human body should be recognized in ventilation design practice....

  10. Robust 3D Position Estimation in Wide and Unconstrained Indoor Environments

    Directory of Open Access Journals (Sweden)

    Annette Mossel

    2015-12-01

    Full Text Available In this paper, a system for 3D position estimation in wide, unconstrained indoor environments is presented that employs infrared optical outside-in tracking of rigid-body targets with a stereo camera rig. To overcome limitations of state-of-the-art optical tracking systems, a pipeline for robust target identification and 3D point reconstruction has been investigated that enables camera calibration and tracking in environments with poor illumination, static and moving ambient light sources, occlusions and harsh conditions, such as fog. For evaluation, the system has been successfully applied in three different wide and unconstrained indoor environments, (1 user tracking for virtual and augmented reality applications, (2 handheld target tracking for tunneling and (3 machine guidance for mining. The results of each use case are discussed to embed the presented approach into a larger technological and application context. The experimental results demonstrate the system’s capabilities to track targets up to 100 m. Comparing the proposed approach to prior art in optical tracking in terms of range coverage and accuracy, it significantly extends the available tracking range, while only requiring two cameras and providing a relative 3D point accuracy with sub-centimeter deviation up to 30 m and low-centimeter deviation up to 100 m.

  11. A Robust Method for Detecting Parking Areas in Both Indoor and Outdoor Environments

    Directory of Open Access Journals (Sweden)

    Wenhao Zong

    2018-06-01

    Full Text Available Although an automatic parking system has been installed in many vehicles recently, it is still hard for the system to confirm by itself whether a vacant parking area truly exists or not. In this paper, we introduced a robust vision-based vacancy parking area detecting method for both indoor and outdoor environments. The main contribution of this paper is given as follows. First, an automatic image stitching method is proposed. Secondly, the problem of environment illuminating change and line color difference is considered and solved. Thirdly, the proposed algorithm is insensitive to the shadow and scene diversity, which means the detecting result satisfies most of the environment. Finally, a vehicle model is considered for tracking and reconfirming the detecting results to eliminate most of the false positives.

  12. A structural regression model for relationship between indoor air quality with dissatisfaction of occupants in education environment

    Science.gov (United States)

    Hosseini, Hamid Reza; Yunos, Mohd Yazid Mohd; Ismail, Sumarni; Yaman, Maheran

    2017-12-01

    This paper analysis the effects of indoor air elements on the dissatisfaction of occupants in education of environments. Tries to find the equation model for increasing the comprehension about these affects and optimizes satisfaction of occupants about indoor environment. Subsequently, increase performance of students, lecturers and staffs. As the method, a satisfaction questionnaire (SQ) and measuring environment elements (MEE) was conducted, 143 respondents at five classrooms, four staff rooms and five lectures rooms were considered. Temperature, air velocity and humidity (TVH) were used as independent variables and dissatisfaction as dependent variable. The hypothesis was tested for significant relationship between variables, and analysis was applied. Results found that indoor air quality presents direct effects on dissatisfaction of occupants and indirect effects on performance and the highest effects fallowed by temperature. These results may help to optimize the quality of efficiency and effectiveness in education environments.

  13. Subjective annoyance caused by indoor low-level and low frequency noise and control method

    Institute of Scientific and Technical Information of China (English)

    DI Guo-qing; ZHANG Bang-jun; SHANG Qi

    2005-01-01

    The influence of low-level noise has not been widely noticed. This paper discovered that low-level and low frequency noise(Aweighted equivalent level Leq < 45 dB) causes higher probability of subjective annoyance. The fuzzy mathematic principle was applied to deal with the threshold level of subjective annoyance from noise in this study; there is preferable relationship between the indoor noise and noise annoyance at low frequency noise level. Study indicated at the same centered noise level, the change of annoyance probability is mainly caused by the change of the frequency spectrum characteristic of the indoor noise. Under low noise level environment, without change of the medium-low frequency noise, the slight increase of medium-high frequency noise level with the help of noise sheltering effect can significantly reduce the noise annoyance. This discovery brings a new resolution on how to improve the environmental quality of working or living places. A noise control model is given in this study according to the acoustic analysis.

  14. NIAID, NIEHS, NHLBI, and MCAN Workshop Report: The indoor environment and childhood asthma-implications for home environmental intervention in asthma prevention and management.

    Science.gov (United States)

    Gold, Diane R; Adamkiewicz, Gary; Arshad, Syed Hasan; Celedón, Juan C; Chapman, Martin D; Chew, Ginger L; Cook, Donald N; Custovic, Adnan; Gehring, Ulrike; Gern, James E; Johnson, Christine C; Kennedy, Suzanne; Koutrakis, Petros; Leaderer, Brian; Mitchell, Herman; Litonjua, Augusto A; Mueller, Geoffrey A; O'Connor, George T; Ownby, Dennis; Phipatanakul, Wanda; Persky, Victoria; Perzanowski, Matthew S; Ramsey, Clare D; Salo, Päivi M; Schwaninger, Julie M; Sordillo, Joanne E; Spira, Avrum; Suglia, Shakira F; Togias, Alkis; Zeldin, Darryl C; Matsui, Elizabeth C

    2017-10-01

    Environmental exposures have been recognized as critical in the initiation and exacerbation of asthma, one of the most common chronic childhood diseases. The National Institute of Allergy and Infectious Diseases; National Institute of Environmental Health Sciences; National Heart, Lung, and Blood Institute; and Merck Childhood Asthma Network sponsored a joint workshop to discuss the current state of science with respect to the indoor environment and its effects on the development and morbidity of childhood asthma. The workshop included US and international experts with backgrounds in allergy/allergens, immunology, asthma, environmental health, environmental exposures and pollutants, epidemiology, public health, and bioinformatics. Workshop participants provided new insights into the biologic properties of indoor exposures, indoor exposure assessment, and exposure reduction techniques. This informed a primary focus of the workshop: to critically review trials and research relevant to the prevention or control of asthma through environmental intervention. The participants identified important limitations and gaps in scientific methodologies and knowledge and proposed and prioritized areas for future research. The group reviewed socioeconomic and structural challenges to changing environmental exposure and offered recommendations for creative study design to overcome these challenges in trials to improve asthma management. The recommendations of this workshop can serve as guidance for future research in the study of the indoor environment and on environmental interventions as they pertain to the prevention and management of asthma and airway allergies. Published by Elsevier Inc.

  15. The lasting effect of limonene-induced particle formation on air quality in a genuine indoor environment.

    Science.gov (United States)

    Rösch, Carolin; Wissenbach, Dirk K; von Bergen, Martin; Franck, Ulrich; Wendisch, Manfred; Schlink, Uwe

    2015-09-01

    Atmospheric ozone-terpene reactions, which form secondary organic aerosol (SOA) particles, can affect indoor air quality when outdoor air mixes with indoor air during ventilation. This study, conducted in Leipzig, Germany, focused on limonene-induced particle formation in a genuine indoor environment (24 m(3)). Particle number, limonene and ozone concentrations were monitored during the whole experimental period. After manual ventilation for 30 min, during which indoor ozone levels reached up to 22.7 ppb, limonene was introduced into the room at concentrations of approximately 180 to 250 μg m(-3). We observed strong particle formation and growth within a diameter range of 9 to 50 nm under real-room conditions. Larger particles with diameters above 100 nm were less affected by limonene introduction. The total particle number concentrations (TPNCs) after limonene introduction clearly exceed outdoor values by a factor of 4.5 to 41 reaching maximum concentrations of up to 267,000 particles cm(-3). The formation strength was influenced by background particles, which attenuated the formation of new SOA with increasing concentration, and by ozone levels, an increase of which by 10 ppb will result in a six times higher TPNC. This study emphasizes indoor environments to be preferred locations for particle formation and growth after ventilation events. As a consequence, SOA formation can produce significantly higher amounts of particles than transported by ventilation into the indoor air.

  16. Toward a Computer Vision-based Wayfinding Aid for Blind Persons to Access Unfamiliar Indoor Environments.

    Science.gov (United States)

    Tian, Yingli; Yang, Xiaodong; Yi, Chucai; Arditi, Aries

    2013-04-01

    Independent travel is a well known challenge for blind and visually impaired persons. In this paper, we propose a proof-of-concept computer vision-based wayfinding aid for blind people to independently access unfamiliar indoor environments. In order to find different rooms (e.g. an office, a lab, or a bathroom) and other building amenities (e.g. an exit or an elevator), we incorporate object detection with text recognition. First we develop a robust and efficient algorithm to detect doors, elevators, and cabinets based on their general geometric shape, by combining edges and corners. The algorithm is general enough to handle large intra-class variations of objects with different appearances among different indoor environments, as well as small inter-class differences between different objects such as doors and door-like cabinets. Next, in order to distinguish intra-class objects (e.g. an office door from a bathroom door), we extract and recognize text information associated with the detected objects. For text recognition, we first extract text regions from signs with multiple colors and possibly complex backgrounds, and then apply character localization and topological analysis to filter out background interference. The extracted text is recognized using off-the-shelf optical character recognition (OCR) software products. The object type, orientation, location, and text information are presented to the blind traveler as speech.

  17. Debating the future of comfort: environmental sustainability, energy consumption and the indoor environment

    Energy Technology Data Exchange (ETDEWEB)

    Chappells, H.; Shove, E.

    2005-02-01

    Vast quantities of energy are consumed in heating and cooling to provide what are now regarded as acceptable standards of thermal comfort. In the UK as in a number of other countries, there is a real danger that responses in anticipation of global warming and climate change - including growing reliance on air-conditioning - will increase energy demand and CO{sub 2} emissions even further. This is an appropriate moment to reflect on the history and future of comfort, both as an idea and as a material reality. Based on interviews and discussions with UK policy makers and building practitioners involved in specifying and constructing what will become the indoor environments of the future, four possible scenarios are identified each with different implications for energy and resource consumption. By actively promoting debate about the indoor environment and associated ways of life, it may yet be possible to avoid becoming locked into social and technical trajectories that are ultimately unsustainable. The aim of this paper is to inspire and initiate just such a discussion through demonstrating that comfort is a highly negotiable socio-cultural construct. (author)

  18. Youth indoor tanning and skin cancer prevention: lessons from tobacco control.

    Science.gov (United States)

    Seidenberg, Andrew B; Mahalingam-Dhingra, Aditya; Weinstock, Martin A; Sinclair, Craig; Geller, Alan C

    2015-02-01

    Youth use of ultraviolet-emitting indoor tanning beds represents a present and emerging public health crisis. Nearly 30% of white female high school students report tanning indoors, and a quarter of high school tanners have used a tanning bed more than 20 times in the past year. Despite the significant health risks of tanning beds, including potentially deadly melanoma and eye problems, limited actions have been taken in the U.S. to protect youth. Tobacco control policies and campaigns, which have sharply reduced youth smoking, may provide a useful framework to control indoor tanning among young people. This article describes several evidence-based tobacco control strategies with potential applicability to indoor tanning within the context of the U.S. Further, current tobacco control policies and current indoor tanning policies in the U.S. are compared, and recommendations on how to curtail youth indoor tanning are discussed. Copyright © 2015 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  19. An experimental study on effects of increased ventilation flow on students' perception of indoor environment in computer classrooms.

    Science.gov (United States)

    Norbäck, D; Nordström, K

    2008-08-01

    The effects of ventilation in computer classrooms were studied with university students (n = 355) in a blinded study, 31% were women and 3.8% had asthma. Two classrooms had a higher air exchange (4.1-5.2 ac/h); two others had a lower air exchange (2.3-2.6 ac/h). After 1 week, ventilation conditions were shifted. The students reported environmental perceptions during the last hour. Room temperature, RH, CO2, PM10 and ultra-fine particles were measured simultaneously. Mean CO2 was 1185 ppm at lower and 922 ppm at higher air exchange. Mean temperature was 23.2 degrees C at lower and 22.1 degrees C at higher air exchange. After mutual adjustment (temperature, RH, CO2, air exchange), measured temperature was associated with a perception of higher temperature (P thermal comfort and air quality. Computer classrooms are crowded indoor environments with a high thermal load from both students and computer equipment. It is important to control room temperature either by air conditioning, sun shields, or sufficiently high ventilation flow. A high ventilation flow is also crucial to achieving good perceived air quality. Personal ventilation flow should be at least 10 l/s. Possible loss of learning ability due to poor indoor air quality in university buildings deserves more attention.

  20. Characterization of Particulate Matter Concentrations during Controlled Indoor Activities

    Czech Academy of Sciences Publication Activity Database

    Glytsos, T.; Ondráček, Jakub; Ondráčková, Lucie; Kopanakis, I.; Lazaridis, M.

    2010-01-01

    Roč. 44, č. 12 (2010), s. 1539-1549 ISSN 1352-2310 Grant - others:MTDK(XE) CT/2004/513849 Institutional research plan: CEZ:AV0Z40720504 Keywords : indoor sources * number size distribution * emission rates Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 3.226, year: 2010

  1. Healthy environmentindoor air quality of Brazilian elementary schools nearby petrochemical industry

    International Nuclear Information System (INIS)

    Godoi, Ricardo H.M.; Godoi, Ana F.L.; Gonçalves Junior, Sérgio J.; Paralovo, Sarah L.; Borillo, Guilherme C.; Gonçalves Gregório Barbosa, Cybelli; Arantes, Manoela G.; Charello, Renata C.; Rosário Filho, Nelson A.; Grassi, Marco T.; Yamamoto, Carlos I.; Potgieter-Vermaak, Sanja; Rotondo, Giuliana G.; De Wael, Karolien; Grieken, Rene van

    2013-01-01

    The mitigation of pollution released to the environment originating from the industrial sector has been the aim of all policy-makers and its importance is evident if the adverse health effects on the world population are considered. Although this concern is controversial, petroleum refinery has been linked to some adverse health effects for people living nearby. Apart from home, school is the most important indoor environment for children and there is increasing concern about the school environment and its impact on health, also in developing countries where the prevalence of pollution is higher. As most of the children spend more than 40% of their time in schools, it is critical to evaluate the pollution level in such environment. In the metropolitan region of Curitiba, South Brazil, five schools nearby industries and highways with high density traffic, were selected to characterize the aerosol and gaseous compounds indoor and outdoor of the classrooms, during 2009–2011. Size segregated aerosol samples were collected for analyses of bulk and single particle elemental profiles. They were analyzed by electron probe X-ray micro-analysis (EPXMA), and by energy-dispersive X-ray fluorescence (EDXRF), to investigate the elemental composition of individual particles and bulk samples. The concentrations of benzene, toluene, ethylbenzene, and xylene (BTEX); NO 2 ; SO 2 ; acetic acid; and formic acid were assessed indoor and outdoor using passive diffusion tubes. BTEX were analyzed by GC–MS and other collected gasses by ion chromatography. Individual exposition of BTEX was assessed by personal passive diffusion tubes. Results are interpreted separately and as a whole with the specific aim of identifying compounds that could affect the health of the scholars. In view of the chemical composition and size distribution of the aerosol particles, local deposition efficiencies in the children's respiratory systems were calculated, revealing the deposition of particles at

  2. Healthy environmentindoor air quality of Brazilian elementary schools nearby petrochemical industry

    Energy Technology Data Exchange (ETDEWEB)

    Godoi, Ricardo H.M., E-mail: rhmgodoi@ufpr.br [Department of Environmental Engineering, Federal University of Paran UFPR, Curitiba, PR (Brazil); Godoi, Ana F.L.; Gonçalves Junior, Sérgio J.; Paralovo, Sarah L.; Borillo, Guilherme C.; Gonçalves Gregório Barbosa, Cybelli; Arantes, Manoela G.; Charello, Renata C. [Department of Environmental Engineering, Federal University of Paran UFPR, Curitiba, PR (Brazil); Rosário Filho, Nelson A. [Department of Pediatric, Div. of Allergy and Pneumol, Federal University of Paran Curitiba, PR (Brazil); Grassi, Marco T. [Department of Chemistry, Federal University of Paraná, Curitiba, PR (Brazil); Yamamoto, Carlos I. [Department of Chemistry Engineering, Federal University of Paraná, Curitiba, PR (Brazil); Potgieter-Vermaak, Sanja [Division of Chemistry and Environmental Science, School of Science and the Environment, Manchester Metropolitan University, Manchester (United Kingdom); Rotondo, Giuliana G.; De Wael, Karolien; Grieken, Rene van [Department of Chemistry, University of Antwerp, Universiteitsplein 1, B-2610 Antwerp (Belgium)

    2013-10-01

    The mitigation of pollution released to the environment originating from the industrial sector has been the aim of all policy-makers and its importance is evident if the adverse health effects on the world population are considered. Although this concern is controversial, petroleum refinery has been linked to some adverse health effects for people living nearby. Apart from home, school is the most important indoor environment for children and there is increasing concern about the school environment and its impact on health, also in developing countries where the prevalence of pollution is higher. As most of the children spend more than 40% of their time in schools, it is critical to evaluate the pollution level in such environment. In the metropolitan region of Curitiba, South Brazil, five schools nearby industries and highways with high density traffic, were selected to characterize the aerosol and gaseous compounds indoor and outdoor of the classrooms, during 2009–2011. Size segregated aerosol samples were collected for analyses of bulk and single particle elemental profiles. They were analyzed by electron probe X-ray micro-analysis (EPXMA), and by energy-dispersive X-ray fluorescence (EDXRF), to investigate the elemental composition of individual particles and bulk samples. The concentrations of benzene, toluene, ethylbenzene, and xylene (BTEX); NO{sub 2}; SO{sub 2}; acetic acid; and formic acid were assessed indoor and outdoor using passive diffusion tubes. BTEX were analyzed by GC–MS and other collected gasses by ion chromatography. Individual exposition of BTEX was assessed by personal passive diffusion tubes. Results are interpreted separately and as a whole with the specific aim of identifying compounds that could affect the health of the scholars. In view of the chemical composition and size distribution of the aerosol particles, local deposition efficiencies in the children's respiratory systems were calculated, revealing the deposition of

  3. Action tagging in a multi-user indoor environment for behavioural analysis purposes.

    Science.gov (United States)

    Guerra, Claudio; Bianchi, Valentina; De Munari, Ilaria; Ciampolini, Paolo

    2015-01-01

    EU population is getting older, so that ICT-based solutions are expected to provide support in the challenges implied by the demographic change. At the University of Parma an AAL (Ambient Assisted Living) system, named CARDEA, has been developed. In this paper a new feature of the system is introduced, in which environmental and personal (i.e., wearable) sensors coexist, providing an accurate picture of the user's activity and needs. Environmental devices may greatly help in performing activity recognition and behavioral analysis tasks. However, in a multi-user environment, this implies the need of attributing environmental sensors outcome to a specific user, i.e., identifying the user when he performs a task detected by an environmental device. We implemented such an "action tagging" feature, based on information fusion, within the CARDEA environment, as an inexpensive, alternative solution to the problematic issue of indoor locationing.

  4. Airborne particles in indoor environment of homes, schools, offices and aged care facilities: The main routes of exposure.

    Science.gov (United States)

    Morawska, L; Ayoko, G A; Bae, G N; Buonanno, G; Chao, C Y H; Clifford, S; Fu, S C; Hänninen, O; He, C; Isaxon, C; Mazaheri, M; Salthammer, T; Waring, M S; Wierzbicka, A

    2017-11-01

    It has been shown that the exposure to airborne particulate matter is one of the most significant environmental risks people face. Since indoor environment is where people spend the majority of time, in order to protect against this risk, the origin of the particles needs to be understood: do they come from indoor, outdoor sources or both? Further, this question needs to be answered separately for each of the PM mass/number size fractions, as they originate from different sources. Numerous studies have been conducted for specific indoor environments or under specific setting. Here our aim was to go beyond the specifics of individual studies, and to explore, based on pooled data from the literature, whether there are generalizable trends in routes of exposure at homes, schools and day cares, offices and aged care facilities. To do this, we quantified the overall 24h and occupancy weighted means of PM 10 , PM 2.5 and PN - particle number concentration. Based on this, we developed a summary of the indoor versus outdoor origin of indoor particles and compared the means to the WHO guidelines (for PM 10 and PM 2.5 ) and to the typical levels reported for urban environments (PN). We showed that the main origins of particle metrics differ from one type of indoor environment to another. For homes, outdoor air is the main origin of PM 10 and PM 2.5 but PN originate from indoor sources; for schools and day cares, outdoor air is the source of PN while PM 10 and PM 2.5 have indoor sources; and for offices, outdoor air is the source of all three particle size fractions. While each individual building is different, leading to differences in exposure and ideally necessitating its own assessment (which is very rarely done), our findings point to the existence of generalizable trends for the main types of indoor environments where people spend time, and therefore to the type of prevention measures which need to be considered in general for these environments. Copyright © 2017 The

  5. Method for design of low-energy type houses based on simulations of indoor environment and energy use

    DEFF Research Database (Denmark)

    Vanhoutteghem, Lies

    2013-01-01

    with current and future energy requirements, the influence of window size, type and orientation on space heating demand and thermal indoor environment were investigated in EnergyPlus by comparing a window design with an even distribution (same glazingto-floor-area in each room) with a traditional window design....... Charts illustrating a space of solutions for space heating demand defined by targets for daylight and thermal indoor environment were used to discuss the effect of different window parameters and potential conflicts related to window design were identified in deep or narrow southoriented side-lit rooms...

  6. [The community succession of sarcosaphagous insects on pig carcasses in summer indoor and outdoor environment in Shenzhen area].

    Science.gov (United States)

    Yin, Xiao-Jun; Ma, Meng-Yun; Zhou, Hui; Lai, Yue; Wang, Jiang-Feng

    2014-06-01

    To explore the growing development and community succession of main sarcosaphagous insects on pig carcasses in summer indoor and outdoor environment in Shenzhen area and to estimate the postmortem interval (PMI). From early May to August in 2013, in Forensic Medical Examination Center of Shenzhen Public Security Bureau, the main insect species and the decomposition process were observed in two adult pig carcasses of simulative indoor and outdoor environment. The different decomposition stages and the community succession of insects were recorded. The indoor and outdoor pig carcasses showed skeleton 412.5 and 325 hours after death, respectively. The main species of flies on pig carcasses were Chrysomya megacephala, Chrysomya rufifacies and Chrysomya chani. The main species of beetles were Crecphilus maxillosus, Necrobia ruficollis, Saprinus splendens and Dermestes maculatu. The dominant species of flies in the outdoor pig carcasses obviously produced the second generations due to the effect of mass rainfall, nor in the indoor pig carcasses. There are regular patterns on the community succession of insects on pig carcasses in summer indoor and outdoor environment in Shenzhen area. The activity patterns of seven typical insects and their larva show important value for estimating PMI.

  7. Study on the influence of CR-39 detector size on radon progeny detection in indoor environments

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, L. A.; Hadler, J. C.; Lixandrão F, A. L.; Guedes, S.; Takizawa, R. H. [Instituto de Física Gleb Wataghin, Universidade Estadual de Campinas, UNICAMP, 13083-970 Campinas, SP (Brazil)

    2014-11-11

    It is well known that radon daughters up to {sup 214}Po are the real contaminants to be considered in case of indoor radon contamination. Assemblies consisting of 6 circular bare sheets of CR-39, a nuclear track detector, with radius varying from 0.15 to 1.2 cm were exposed far from any material surface for periods of approximately 6 months in 13 different indoor rooms (7 workplaces and 6 dwellings), where ventilation was moderate or poor. It was observed that track density was as greater as smaller was the detector radius. Track density data were fitted using an equation deduced based on the assumption that the behavior of radon and its progeny in the air was described by Fick's Law, i.e., when the main mechanism of transport of radon progeny in the air is diffusion. As many people spend great part of their time in closed or poorly ventilated environments, the confirmation they present equilibrium between radon and its progeny is an interesting start for dosimetric calculations concerning this contamination.

  8. Comparison of sensor systems designed using multizone, zonal, and CFD data for protection of indoor environments

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Y. Lisa; Wen, Jin [Civil, Architectural, and Environmental Engineering, Drexel University, Philadelphia, PA 19104 (United States)

    2010-04-15

    Sensors that detect chemical and biological warfare agents can offer early warning of dangerous contaminants. However, current sensor system design is mostly by intuition and experience rather than by systematic design. To develop a sensor system design methodology, the proper selection of an indoor airflow model is needed. Various indoor airflow models exist in the literature, from complex computational fluid dynamics (CFD) to simpler approaches such as multizone and zonal models. Airflow models provide the contaminant concentration data, to which an optimization method can be applied to design sensor systems. The authors utilized a subzonal modeling approach when using a multizone model and were the first to utilize a zonal model for systematic sensor system design. The objective of the study was to examine whether or not data from a simpler airflow model could be used to design sensor systems capable of performing just as well as those designed using data from more complex CFD models. Three test environments, a small office, a large hall, and an office suite were examined. Results showed that when a unique sensor system design was not needed, sensor systems designed using data from simpler airflow models could perform just as well as those designed using CFD data. Further, only for the small office did the common engineering sensor system design practice of placing a sensor at the exhaust result in sensor system performance that was equivalent to one designed using CFD data. (author)

  9. Natural indoor gamma background in an urban environment of Southern Poland

    International Nuclear Information System (INIS)

    Koperski, J.

    1984-01-01

    A regional survey of indoor exposure to natural gamma background from terrestrial sources was performed in the urban environment of six administrative provinces of Southern Poland. 1351 dwelling houses at 144 localities were monitored using of LiF:Mg,Ti thermoluminescence dosemeters. The dose rates observed indoors were between 32 and 185 nGy.h -1 and were strongly dependent on the types of building materials used in the dwellings monitored. The highest mean provincial values were found in slag and fly-ash dwellings (77-123 nGy.h -1 ), while in wooden dwellings these values were the lowest (42-51 nGy.h -1 ). Intermediate values occurred in clay brick dwellings (57-102 nGy.h -1 ), in dwellings of mixed, wooden-brick construction (60-79 nGy,h -1 ) and in dwellings made of gravel-sand prefabricates (52-68 nGy.h -1 ). The calculated mean annual per capita effective dose equivalent rates ranged between 0.2 mSv.y -1 , for the inhabitants of wooden houses, and 0.6 mSv.y -1 for those living in houses made of coal by-product prefabricates. (author)

  10. Indoor thermal environment, air exchange rates, and carbon dioxide concentrations before and after energy retro fits in Finnish and Lithuanian multi-family buildings.

    Science.gov (United States)

    Leivo, Virpi; Prasauskas, Tadas; Du, Liuliu; Turunen, Mari; Kiviste, Mihkel; Aaltonen, Anu; Martuzevicius, Dainius; Haverinen-Shaughnessy, Ulla

    2018-04-15

    Impacts of energy retrofits on indoor thermal environment, i.e. temperature (T) and relative humidity (RH), as well as ventilation rates and carbon dioxide (CO 2 ) concentrations, were assessed in 46 Finnish and 20 Lithuanian multi-family buildings, including 39 retrofitted case buildings in Finland and 15 in Lithuania (the remaining buildings were control buildings with no retrofits). In the Finnish buildings, high indoor T along with low RH levels was commonly observed both before and after the retrofits. Ventilation rates (l/s per person) were higher after the retrofits in buildings with mechanical exhaust ventilation than the corresponding values before the retrofits. Measured CO 2 levels were low in vast majority of buildings. In Lithuania, average indoor T levels were low before the retrofits and there was a significant increase in the average T after the retrofits. In addition, average ventilation rate was lower and CO 2 levels were higher after the retrofits in the case buildings (N=15), both in apartments with natural and mixed ventilation. Based on the results, assessment of thermal conditions and ventilation rates after energy retrofits is crucial for optimal indoor environmental quality and energy use. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Improving the Health of Workers in Indoor Environments: Priority Research Needs for a National Occupational Research Agenda

    Science.gov (United States)

    Mendell, Mark J.; Fisk, William J.; Kreiss, Kathleen; Levin, Hal; Alexander, Darryl; Cain, William S.; Girman, John R.; Hines, Cynthia J.; Jensen, Paul A.; Milton, Donald K.; Rexroat, Larry P.; Wallingford, Kenneth M.

    2002-01-01

    Indoor nonindustrial work environments were designated a priority research area through the nationwide stakeholder process that created the National Occupational Research Agenda. A multidisciplinary research team used member consensus and quantitative estimates, with extensive external review, to develop a specific research agenda. The team outlined the following priority research topics: building-influenced communicable respiratory infections, building-related asthma/allergic diseases, and nonspecific building-related symptoms; indoor environmental science; and methods for increasing implementation of healthful building practices. Available data suggest that improving building environments may result in health benefits for more than 15 million of the 89 million US indoor workers, with estimated economic benefits of $5 to $75 billion annually. Research on these topics, requiring new collaborations and resources, offers enormous potential health and economic returns. PMID:12197969

  12. Engaging Moms on Teen Indoor Tanning Through Social Media: Protocol of a Randomized Controlled Trial.

    Science.gov (United States)

    Pagoto, Sherry L; Baker, Katie; Griffith, Julia; Oleski, Jessica L; Palumbo, Ashley; Walkosz, Barbara J; Hillhouse, Joel; Henry, Kimberly L; Buller, David B

    2016-11-29

    Indoor tanning elevates the risk for melanoma, which is now the most common cancer in US women aged 25-29. Public policies restricting access to indoor tanning by minors to reduce melanoma morbidity and mortality in teens are emerging. In the United States, the most common policy restricting indoor tanning in minors involves parents providing either written or in person consent for the minor to purchase a tanning visit. The effectiveness of this policy relies on parents being properly educated about the harms of indoor tanning to their children. This randomized controlled trial will test the efficacy of a Facebook-delivered health communication intervention targeting mothers of teenage girls. The intervention will use health communication and behavioral modification strategies to reduce mothers' permissiveness regarding their teenage daughters' use of indoor tanning relative to an attention-control condition with the ultimate goal of reducing indoor tanning in both daughters and mothers. The study is a 12-month randomized controlled trial comparing 2 conditions: an attention control Facebook private group where content will be relevant to teen health with 25% focused on prescription drug abuse, a topic unrelated to tanning; and the intervention condition will enter participants into a Facebook private group where 25% of the teen health content will be focused on indoor tanning. A cohort of 2000 mother-teen daughter dyads will be recruited to participate in this study. Only mothers will participate in the Facebook groups. Both mothers and daughters will complete measures at baseline, end of intervention (1-year) and 6 months post-intervention. Primary outcomes include mothers' permissiveness regarding their teenage daughters' use of indoor tanning, teenage daughters' perception of their mothers' permissiveness, and indoor tanning by both mothers and daughters. The first dyad was enrolled on March 31, 2016, and we anticipate completing this study by October 2019

  13. Engaging Moms on Teen Indoor Tanning Through Social Media: Protocol of a Randomized Controlled Trial

    Science.gov (United States)

    Baker, Katie; Griffith, Julia; Oleski, Jessica L; Palumbo, Ashley; Walkosz, Barbara J; Hillhouse, Joel; Henry, Kimberly L; Buller, David B

    2016-01-01

    Background Indoor tanning elevates the risk for melanoma, which is now the most common cancer in US women aged 25-29. Public policies restricting access to indoor tanning by minors to reduce melanoma morbidity and mortality in teens are emerging. In the United States, the most common policy restricting indoor tanning in minors involves parents providing either written or in person consent for the minor to purchase a tanning visit. The effectiveness of this policy relies on parents being properly educated about the harms of indoor tanning to their children. Objective This randomized controlled trial will test the efficacy of a Facebook-delivered health communication intervention targeting mothers of teenage girls. The intervention will use health communication and behavioral modification strategies to reduce mothers’ permissiveness regarding their teenage daughters’ use of indoor tanning relative to an attention-control condition with the ultimate goal of reducing indoor tanning in both daughters and mothers. Methods The study is a 12-month randomized controlled trial comparing 2 conditions: an attention control Facebook private group where content will be relevant to teen health with 25% focused on prescription drug abuse, a topic unrelated to tanning; and the intervention condition will enter participants into a Facebook private group where 25% of the teen health content will be focused on indoor tanning. A cohort of 2000 mother-teen daughter dyads will be recruited to participate in this study. Only mothers will participate in the Facebook groups. Both mothers and daughters will complete measures at baseline, end of intervention (1-year) and 6 months post-intervention. Primary outcomes include mothers’ permissiveness regarding their teenage daughters’ use of indoor tanning, teenage daughters’ perception of their mothers’ permissiveness, and indoor tanning by both mothers and daughters. Results The first dyad was enrolled on March 31, 2016, and we

  14. An Indoor Location-Based Control System Using Bluetooth Beacons for IoT Systems.

    Science.gov (United States)

    Huh, Jun-Ho; Seo, Kyungryong

    2017-12-19

    The indoor location-based control system estimates the indoor position of a user to provide the service he/she requires. The major elements involved in the system are the localization server, service-provision client, user application positioning technology. The localization server controls access of terminal devices (e.g., Smart Phones and other wireless devices) to determine their locations within a specified space first and then the service-provision client initiates required services such as indoor navigation and monitoring/surveillance. The user application provides necessary data to let the server to localize the devices or allow the user to receive various services from the client. The major technological elements involved in this system are indoor space partition method, Bluetooth 4.0, RSSI (Received Signal Strength Indication) and trilateration. The system also employs the BLE communication technology when determining the position of the user in an indoor space. The position information obtained is then used to control a specific device(s). These technologies are fundamental in achieving a "Smart Living". An indoor location-based control system that provides services by estimating user's indoor locations has been implemented in this study (First scenario). The algorithm introduced in this study (Second scenario) is effective in extracting valid samples from the RSSI dataset but has it has some drawbacks as well. Although we used a range-average algorithm that measures the shortest distance, there are some limitations because the measurement results depend on the sample size and the sample efficiency depends on sampling speeds and environmental changes. However, the Bluetooth system can be implemented at a relatively low cost so that once the problem of precision is solved, it can be applied to various fields.

  15. An Indoor Location-Based Control System Using Bluetooth Beacons for IoT Systems

    Directory of Open Access Journals (Sweden)

    Jun-Ho Huh

    2017-12-01

    Full Text Available The indoor location-based control system estimates the indoor position of a user to provide the service he/she requires. The major elements involved in the system are the localization server, service-provision client, user application positioning technology. The localization server controls access of terminal devices (e.g., Smart Phones and other wireless devices to determine their locations within a specified space first and then the service-provision client initiates required services such as indoor navigation and monitoring/surveillance. The user application provides necessary data to let the server to localize the devices or allow the user to receive various services from the client. The major technological elements involved in this system are indoor space partition method, Bluetooth 4.0, RSSI (Received Signal Strength Indication and trilateration. The system also employs the BLE communication technology when determining the position of the user in an indoor space. The position information obtained is then used to control a specific device(s. These technologies are fundamental in achieving a “Smart Living”. An indoor location-based control system that provides services by estimating user’s indoor locations has been implemented in this study (First scenario. The algorithm introduced in this study (Second scenario is effective in extracting valid samples from the RSSI dataset but has it has some drawbacks as well. Although we used a range-average algorithm that measures the shortest distance, there are some limitations because the measurement results depend on the sample size and the sample efficiency depends on sampling speeds and environmental changes. However, the Bluetooth system can be implemented at a relatively low cost so that once the problem of precision is solved, it can be applied to various fields.

  16. Diversity and taxonomy of Chaetomium and chaetomium-like fungi from indoor environments

    Directory of Open Access Journals (Sweden)

    X.W. Wang

    2016-06-01

    Full Text Available During a study of indoor fungi, 145 isolates belonging to Chaetomiaceae were cultured from air, swab and dust samples from 19 countries. Based on the phylogenetic analyses of DNA-directed RNA polymerase II second largest subunit (rpb2, β-tubulin (tub2, ITS and 28S large subunit (LSU nrDNA sequences, together with morphological comparisons with related genera and species, 30 indoor taxa are recognised, of which 22 represent known species, seven are described as new, and one remains to be identified to species level. In our collection, 69 % of the indoor isolates with six species cluster with members of the Chaetomium globosum species complex, representing Chaetomium sensu stricto. The other indoor species fall into nine lineages that are separated from each other with several known chaetomiaceous genera occurring among them. No generic names are available for five of those lineages, and the following new genera are introduced here: Amesia with three indoor species, Arcopilus with one indoor species, Collariella with four indoor species, Dichotomopilus with seven indoor species and Ovatospora with two indoor species. The generic concept of Botryotrichum is expanded to include Emilmuelleria and the chaetomium-like species B. muromum (= Ch. murorum in which two indoor species are included. The generic concept of Subramaniula is expanded to include several chaetomium-like taxa as well as one indoor species. Humicola is recognised as a distinct genus including two indoor taxa. According to this study, Ch. globosum is the most abundant Chaetomiaceae indoor species (74/145, followed by Ch. cochliodes (17/145, Ch. elatum (6/145 and B. piluliferum (5/145. The morphological diversity of indoor Chaetomiaceae as well as the morphological characteristics of the new genera are described and illustrated. This taxonomic study redefines the generic concept of Chaetomium and provides new insight into the phylogenetic relationships among different genera within

  17. Automated linear regression tools improve RSSI WSN localization in multipath indoor environment

    Directory of Open Access Journals (Sweden)

    Laermans Eric

    2011-01-01

    Full Text Available Abstract Received signal strength indication (RSSI-based localization is emerging in wireless sensor networks (WSNs. Localization algorithms need to include the physical and hardware limitations of RSSI measurements in order to give more accurate results in dynamic real-life indoor environments. In this study, we use the Interdisciplinary Institute for Broadband Technology real-life test bed and present an automated method to optimize and calibrate the experimental data before offering them to a positioning engine. In a preprocessing localization step, we introduce a new method to provide bounds for the range, thereby further improving the accuracy of our simple and fast 2D localization algorithm based on corrected distance circles. A maximum likelihood algorithm with a mean square error cost function has a higher position error median than our algorithm. Our experiments further show that the complete proposed algorithm eliminates outliers and avoids any manual calibration procedure.

  18. Indoor climate, psychosocial work environment and symptoms in open-plan offices

    DEFF Research Database (Denmark)

    Pejtersen, J; Allermann, L; Kristensen, T S

    2006-01-01

    To study the indoor climate, the psychosocial work environment and occupants' symptoms in offices a cross-sectional questionnaire survey was made in 11 naturally and 11 mechanically ventilated office buildings. Nine of the buildings had mainly cellular offices; five of the buildings had mainly open...... irritation, skin irritation, central nervous system (CNS) symptoms and psychosocial factors. Occupants in open-plan offices are more likely to perceive thermal discomfort, poor air quality and noise and they more frequently complain about CNS and mucous membrane symptoms than occupants in multi......-person and cellular offices. The association between psychosocial factors and office size was weak. Open-plan offices may not be suited for all job types. PRACTICAL IMPLICATION: Open-plan offices may be a risk factor for adverse environmental perceptions and symptoms....

  19. Energy Consumption and Indoor Environment Predicted by a Combination of Computational Fluid Dynamics and Building Energy Performance Simulation

    DEFF Research Database (Denmark)

    Nielsen, Peter Vilhelm

    2003-01-01

    An interconnection between a building energy performance simulation program and a Computational Fluid Dynamics program (CFD) for room air distribution is introduced for improvement of the predictions of both the energy consumption and the indoor environment.The article describes a calculation...

  20. Stress-reducing effects of indoor plants in the built healthcare environment: The mediating role of perceived attractiveness

    NARCIS (Netherlands)

    Dijkstra, K.; Pieterse, Marcel E.; Pruyn, Adriaan T.H.

    2008-01-01

    Objective: Natural elements in the built healthcare environment have shown to hold potential stress-reducing properties. In order to shed light on the underlying mechanism of stress-reducing effects of nature, the present study investigates whether the stress-reducing effects of indoor plants occur

  1. Stress-reducing effects of indoor plants in the built healthcare environment : The mediating role of perceived attractiveness

    NARCIS (Netherlands)

    Dijkstra, K.; Pieterse, Marcel E.; Pruyn, A.Th.

    Objective: Natural elements in the built healthcare environment have shown to hold potential stress-reducing properties. In order to shed light on the underlying mechanism of stress-reducing effects of nature, the present study investigates whether the stress-reducing effects of indoor plants occur

  2. A Movement-Assisted Deployment of Collaborating Autonomous Sensors for Indoor and Outdoor Environment Monitoring

    Directory of Open Access Journals (Sweden)

    Ewa Niewiadomska-Szynkiewicz

    2016-09-01

    Full Text Available Using mobile robots or unmanned vehicles to assist optimal wireless sensors deployment in a working space can significantly enhance the capability to investigate unknown environments. This paper addresses the issues of the application of numerical optimization and computer simulation techniques to on-line calculation of a wireless sensor network topology for monitoring and tracking purposes. We focus on the design of a self-organizing and collaborative mobile network that enables a continuous data transmission to the data sink (base station and automatically adapts its behavior to changes in the environment to achieve a common goal. The pre-defined and self-configuring approaches to the mobile-based deployment of sensors are compared and discussed. A family of novel algorithms for the optimal placement of mobile wireless devices for permanent monitoring of indoor and outdoor dynamic environments is described. They employ a network connectivity-maintaining mobility model utilizing the concept of the virtual potential function for calculating the motion trajectories of platforms carrying sensors. Their quality and utility have been justified through simulation experiments and are discussed in the final part of the paper.

  3. A Movement-Assisted Deployment of Collaborating Autonomous Sensors for Indoor and Outdoor Environment Monitoring.

    Science.gov (United States)

    Niewiadomska-Szynkiewicz, Ewa; Sikora, Andrzej; Marks, Michał

    2016-09-14

    Using mobile robots or unmanned vehicles to assist optimal wireless sensors deployment in a working space can significantly enhance the capability to investigate unknown environments. This paper addresses the issues of the application of numerical optimization and computer simulation techniques to on-line calculation of a wireless sensor network topology for monitoring and tracking purposes. We focus on the design of a self-organizing and collaborative mobile network that enables a continuous data transmission to the data sink (base station) and automatically adapts its behavior to changes in the environment to achieve a common goal. The pre-defined and self-configuring approaches to the mobile-based deployment of sensors are compared and discussed. A family of novel algorithms for the optimal placement of mobile wireless devices for permanent monitoring of indoor and outdoor dynamic environments is described. They employ a network connectivity-maintaining mobility model utilizing the concept of the virtual potential function for calculating the motion trajectories of platforms carrying sensors. Their quality and utility have been justified through simulation experiments and are discussed in the final part of the paper.

  4. Do indoor environments influence asthma and asthma-related symptoms among adults in homes? A review of the literature

    Directory of Open Access Journals (Sweden)

    Yu Jie

    2011-09-01

    Full Text Available This review summarizes the results of epidemiological studies focusing on the detrimental effects of home environmental factors on asthma morbidity in adults. We reviewed the literature on indoor air quality (IAQ, physical and sociodemographic factors, and asthma morbidity in homes, and identified commonly reported asthma, allergic, and respiratory symptoms involving the home environment. Reported IAQ and asthma morbidity data strongly indicated positive associations between indoor air pollution and adverse health effects in most studies. Indoor factors most consistently associated with asthma and asthma-related symptoms in adults included fuel combustion, mold growth, and environmental tobacco smoke. Environmental exposure may increase an adult’s risk of developing asthma and also may increase the risk of asthma exacerbations. Evaluation of present IAQ levels, exposure characteristics, and the role of exposure to these factors in relation to asthma morbidity is important for improving our understanding, identifying the burden, and for developing and implementing interventions aimed at reducing asthma morbidity.

  5. International lighting in controlled environments workshop: Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-12-31

    Lighting is a central and critical aspect of control in environmental research for plant research and is gaining recognition as a significant factor to control carefully for animal and human research. Thus this workshop was convened to reevaluate the technology that is available today and to work toward developing guidelines for the most effective use of lighting in controlled environments with emphasis on lighting for plants but also to initiate interest in the development of improved guidelines for human and animal research. There are a number of established guidelines for lighting in human and animal environments. Development of new lighting guidelines is necessary for three reasons: (1) recent scientific discoveries show that in addition to supporting the sensation of vision, light has profound nonvisual biological and behavioral effects in both animals and humans; (2) federal regulations (EPACT 1992) are requiring all indoor environments to become more energy efficient with a specific emphasis on energy conservation in lighting; (3) lighting engineers and manufacturers have developed a wealth of new light sources and lighting products that can be applied in animal and human environments. The workshop was aimed at bringing together plant scientists and physical scientists to interact in the discussions. It involved participation of biological scientists involved in studying mechanisms of light reactions and those involved in utilizing lighting for production of plants and maintenance of animals in controlled environments. It included participation of physical scientists from universities and government involved in research as well as those from industry involved in producing lamps and in construction of controlled growth facilities. Selected papers are indexed separately for inclusion in the Energy Science and Technology Database.

  6. Indoor multipath mitigation

    DEFF Research Database (Denmark)

    Dragünas, Kostas; Borre, Kai

    2010-01-01

    There are many applications that require continuous positioning in combined outdoor urban and indoor environments. GNSS has been used for a long time in outdoor environments, while indoor positioning is still a challenging task. One of the major degradations that GNSS receivers experience indoors...

  7. 3D Indoor Building Environment Reconstruction using Least Square Adjustment, Polynomial Kernel, Interval Analysis and Homotopy Continuation

    Directory of Open Access Journals (Sweden)

    A. Jamali

    2016-10-01

    Full Text Available Nowadays, municipalities intend to have 3D city models for facility management, disaster management and architectural planning. Indoor models can be reconstructed from construction plans but sometimes, they are not available or very often, they differ from ‘as-built’ plans. In this case, the buildings and their rooms must be surveyed. One of the most utilized methods of indoor surveying is laser scanning. The laser scanning method allows taking accurate and detailed measurements. However, Terrestrial Laser Scanner is costly and time consuming. In this paper, several techniques for indoor 3D building data acquisition have been investigated. For reducing the time and cost of indoor building data acquisition process, the Trimble LaserAce 1000 range finder is used. The proposed approache use relatively cheap equipment: a light Laser Rangefinder which appear to be feasible, but it needs to be tested to see if the observation accuracy is sufficient for the 3D building modelling. The accuracy of the rangefinder is evaluated and a simple spatial model is reconstructed from real data. This technique is rapid (it requires a shorter time as compared to others, but the results show inconsistencies in horizontal angles for short distances in indoor environments. The range finder horizontal angle sensor was calibrated using a least square adjustment algorithm, a polynomial kernel, interval analysis and homotopy continuation.

  8. The effect of farrowing environment and previous experience on the maternal behaviour of sows in indoor pens and outdoor huts.

    Science.gov (United States)

    Wülbers-Mindermann, M; Berg, C; Illmann, G; Baulain, U; Algers, B

    2015-04-01

    Outdoor farrowing huts facilitate a less restricted maternal behaviour in sows compared with sows kept indoors in farrowing pens. The aim of our study was to investigate whether there are behavioural differences between primiparous sows kept outdoors in farrowing huts and indoors in pens, and whether the maternal behaviour during the second parity, when all sows were kept outdoors in farrowing huts, would differ between sows that have experienced the indoor or the outdoor environment, respectively, during their first parturition. A total of 26 Yorkshire×Swedish Landrace sows were studied. Of these, 11 sows were housed outdoors in farrowing huts during both parturitions (group=OUTOUT). The other 15 sows were kept indoors in a barn with single farrowing pens during their first parturition. During their second parturition, sows were kept outdoors in farrowing huts (group=INOUT). The behaviour was video recorded from 2 h prepartum to 48 h postpartum. The sows' responsiveness to playbacks of a piglet's screams was tested on days 2 to 3 postpartum. Parity 1: during the last 2 h prepartum, OUTOUT sows had a higher proportion of observations in the sternal lying position (Pbehavioural differences between INOUT and OUTOUT sows. In conclusion, it is not problematic for a second parity sow with initial maternal experience from an indoor farrowing pen to be kept outdoors in farrowing huts during its following farrowing.

  9. The influence of individual and contextual psychosocial work factors on the perception of the indoor environment at work: a multilevel analysis

    DEFF Research Database (Denmark)

    Brauer, Charlotte; Mikkelsen, Sigurd

    2010-01-01

    The aim of this study was to investigate the role of the psychosocial work environment--at the individual level as well as the workplace level--in explaining the variability in the employees' perception of the indoor environment.......The aim of this study was to investigate the role of the psychosocial work environment--at the individual level as well as the workplace level--in explaining the variability in the employees' perception of the indoor environment....

  10. Towards Mobile Information Systems for Indoor Space

    Directory of Open Access Journals (Sweden)

    Xiaoxiang Zhang

    2016-01-01

    Full Text Available With the rapid development of Internet of things (IOT and indoor positioning technologies such as Wi-Fi and RFID, indoor mobile information systems have become a new research hotspot. Based on the unique features of indoor space and urgent needs on indoor mobile applications, in this paper we analyze some key issues in indoor mobile information systems, including positioning technologies in indoor environments, representation models for indoor spaces, query processing techniques for indoor moving objects, and index structures for indoor mobile applications. Then, we present an indoor mobile information management system named IndoorDB. Finally, we give some future research topics about indoor mobile information systems.

  11. Contrasts in spatial and temporal variability of oxidative capacity and elemental composition in moxibustion, indoor and outdoor environments in Beijing

    International Nuclear Information System (INIS)

    Huang, Jian; Lim, Min Yee; Hwang, Chaxi; Zhao, Baixiao; Shao, Longyi

    2015-01-01

    Moxibustion is a traditional Chinese medicine therapy that burns moxa floss which produces a substantial amount of PM 10 into the environment, thus spawning safety concerns about health impacts of the smoke. We compared the oxidative capacity and elemental composition of moxibustion-derived and ambient PM 10 in summer and winter to provide a source-, spatial- and temporal-comparison of PM 10 biological responses. The PM 10 oxidative capacity was 2.04 and 1.45 fold lower, and dose-dependent slope gradient was 2.36 and 1.76 fold lower in moxibustion environment than indoor or outdoor. Oxidative damage was highly correlated with iron, cesium, aluminum and cobalt in indoor, but moxibustion environment displayed low associations. The total elemental concentration was also lower in moxibustion environment than indoor (2.28 fold) or outdoor (2.79 fold). The source-to-dose modeling and slope gradient analysis in this study can be used as a model for future source-, spatial- and temporal-related moxibustion safety evaluation studies. - Highlights: • Source-, spatial- and temporal-comparisons of PM 10 of moxa smoke and ambient air. • Moxibustion environment had the lowest oxidative capacity temporally and spatially. • Total elemental concentration was also lowest in moxibustion environment. • Low correlations between metals and oxidative damage in moxibustion environment. • Moxibustion-derived PM 10 may not be as injurious to human health as thought. - Moxibustion-derived PM 10 had the lowest oxidative capacity and total elemental concentration when compared with indoor and outdoor environments

  12. Distributed, signal strength-based indoor localization algorithm for use in healthcare environments.

    Science.gov (United States)

    Wyffels, Jeroen; De Brabanter, Jos; Crombez, Pieter; Verhoeve, Piet; Nauwelaers, Bart; De Strycker, Lieven

    2014-11-01

    In current healthcare environments, a trend toward mobile and personalized interactions between people and nurse call systems is strongly noticeable. Therefore, it should be possible to locate patients at all times and in all places throughout the care facility. This paper aims at describing a method by which a mobile node can locate itself indoors, based on signal strength measurements and a minimal amount of yes/no decisions. The algorithm has been developed specifically for use in a healthcare environment. With extensive testing and statistical support, we prove that our algorithm can be used in a healthcare setting with an envisioned level of localization accuracy up to room revel (or region level in a corridor), while avoiding heavy investments since the hardware of an existing nurse call network can be reused. The approach opted for leads to very high scalability, since thousands of mobile nodes can locate themselves. Network timing issues and localization update delays are avoided, which ensures that a patient can receive the needed care in a time and resources efficient way.

  13. Effect of cold indoor environment on physical performance of older women living in the community.

    Science.gov (United States)

    Lindemann, Ulrich; Oksa, Juha; Skelton, Dawn A; Beyer, Nina; Klenk, Jochen; Zscheile, Julia; Becker, Clemens

    2014-07-01

    the effects of cold on older persons' body and mind are not well documented, but with an increased number of older people with decreasing physical performance, these possible effects need to be understood. to investigate the effect of cold indoor environment on physical performance of older women. cross-sectional experimental study with two test conditions. movement laboratory in a climate chamber. eighty-eight community-dwelling, cognitively unimpaired older women (mean age 78 years). participants were exposed to moderately cold (15°C) and warm/normal (25°C) temperature in a climate chamber in random order with an interval of 1 week. The assessment protocol included leg extensor power (Nottingham Power Rig), sit-to-stand performance velocity (linear encoder), gait speed, walk-ratio (i.e. step length/cadence on an instrumented walk way), maximal quadriceps and hand grip strength. physical performance was lower in 15°C room temperature compared with 25°C room temperature for leg extensor power (P environment decreased important physical performance measures necessary for independent living. © The Author 2014. Published by Oxford University Press on behalf of the British Geriatrics Society. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. A statistical evaluation of the geogenic controls on indoor radon concentrations and radon risk

    Energy Technology Data Exchange (ETDEWEB)

    Appleton, J.D., E-mail: jda@bgs.ac.u [British Geological Survey, Kingsley Dunham Centre, Nicker Hill, Keyworth, Nottingham, NG12 5GG (United Kingdom); Miles, J.C.H. [Health Protection Agency (HPA), Radiation Protection Division, Chilton, Didcot, Oxon OX11 0RQ (United Kingdom)

    2010-10-15

    ANOVA is used to show that approximately 25% of the total variation of indoor radon concentrations in England and Wales can be explained by the mapped bedrock and superficial geology. The proportion of the total variation explained by geology is higher (up to 37%) in areas where there is strong contrast between the radon potential of sedimentary geological units and lower (14%) where the influence of confounding geological controls, such as uranium mineralisation, cut across mapped geological boundaries. When indoor radon measurements are grouped by geology and 1-km squares of the national grid, the cumulative percentage of the variation between and within mapped geological units is shown to be 34-40%. The proportion of the variation that can be attributed to mapped geological units increases with the level of detail of the digital geological data. This study confirms the importance of radon maps that show the variation of indoor radon concentrations both between and within mapped geological boundaries.

  15. Impacts of cooking system on indoor air environment: a case study on a Bangladeshi village

    International Nuclear Information System (INIS)

    Azad, A.K.; Afroze, S.; Azam, M.

    2005-01-01

    Energy is needed to meet the subsistence requirement as well as to meet the demand for economic growth and development. As like many other third world countries still more than half of the total consumed energy comes from the traditional fuels in Bangladesh. This is causing rapid deforestation and consequently a change in the eco-systems leading to erosion and change in the climatic pattern. Extreme use of raw (low quality) biomass traditional cook stoves causes significant impacts on indoor air environment and as well on human health. In the study, an assessment of the cooking energy usage pattern, its potential impacts on indoor air environment and human health in a village named Deyara in Khulna district has been performed. The socio-economic status of the villagers and cooking energy usage pattern were evaluated by a questionnaire survey. In the study village Deyara, about 74% of the total households rely on biomass fuel, where the mostly used biomass is trees and its residues (46%), next the crop wastes (39%) and lastly the cow dung (15%). Emissions of different types of air pollutants and greenhouse gases from the burning of biomass cooking fuels the study village are estimated. In the study area the estimated annual emission of CO/sub 2/ is 45.5 tons which about 94% of the total emission, where CO is 4.5%, PM is 1 % and about 0.5% emission is of SO/sub x/, NO/sub x/, N/sub 2/O. In the study area the concentrations of air pollutants in the kitchen environment were estimated using an indoor air quality model. The model results show that the concentration around the household areas is not at tolerable level and due to only 1 hour biomass burning this concentration is 323 mg/m/sup 3/ for CO, 50.6 mg/m/sup 3/ for PM, 15 mg/m/sup 3/ for NO/sub 2/ and 9.6 mg/m/sup 3/ for SO/sub 2/. Not only this, from the combustion of biomass cooking fuels this concentrations of different carcinogens are also at high levels. For 1 hour burning of biomass fuel this concentration is

  16. 3D Indoor Building Environment Reconstruction using calibration of Range finder Data

    DEFF Research Database (Denmark)

    Jamali, Ali; Anton, François; Rahman, Alias Abdul

    2015-01-01

    Measurement (EDM) and Terrestrial Laser Scanner (TLS) are mostly used. In this paper, several techniques for indoor 3D building data acquisition have been investigated. For reducing the time and cost of indoor building data acquisition process, the Trimble LaserAce 1000 range finder is used. The accuracy...

  17. Fundamentals of mold growth in indoor environments and strategies for healthy living

    NARCIS (Netherlands)

    Adan, O.C.G.; Samson, R.A.

    2011-01-01

    Today, indoor mold and moisture, and their associated health effects, are a society-wide problem. The economic consequences of indoor mold and moisture are enormous. Their global dimension has been emphasized in several recent international publications, stressing that the most important means for

  18. The relationship between perceived health and physical activity indoors, outdoors in built environments, and outdoors in nature.

    Science.gov (United States)

    Pasanen, Tytti P; Tyrväinen, Liisa; Korpela, Kalevi M

    2014-11-01

    A body of evidence shows that both physical activity and exposure to nature are connected to improved general and mental health. Experimental studies have consistently found short term positive effects of physical activity in nature compared with built environments. This study explores whether these benefits are also evident in everyday life, perceived over repeated contact with nature. The topic is important from the perspectives of city planning, individual well-being, and public health. National survey data (n = 2,070) from Finland was analysed using structural regression analyses. Perceived general health, emotional well-being, and sleep quality were regressed on the weekly frequency of physical activity indoors, outdoors in built environments, and in nature. Socioeconomic factors and other plausible confounders were controlled for. Emotional well-being showed the most consistent positive connection to physical activity in nature, whereas general health was positively associated with physical activity in both built and natural outdoor settings. Better sleep quality was weakly connected to frequent physical activity in nature, but the connection was outweighed by other factors. The results indicate that nature provides an added value to the known benefits of physical activity. Repeated exercise in nature is, in particular, connected to better emotional well-being. © 2014 The Authors. Applied Psychology: Health and Well-Being published by John Wiley & Sons Ltd on behalf of The International Association of Applied Psychology.

  19. Polybrominated diphenyl ethers (PBDEs) in the indoor and outdoor environments – A review on occurrence and human exposure

    International Nuclear Information System (INIS)

    Besis, Athanasios; Samara, Constantini

    2012-01-01

    Polybrominated diphenyl ethers (PBDEs) constitute an important group of brominated flame retardants that have been massively produced and extensively used in numerous everyday products, providing longer escape times in case of fire and thus saving lives, as well as reducing the damage of property. In recent years, PBDEs have been recognized as significant pollutants of the indoor environment. This article provides a synthesis and critical evaluation of the state of the knowledge about the occurrence of PBDEs in the indoor environment (air and dust in homes, workplaces and cars) in different countries in Europe, North America, Asia and Australia, as well as about the human exposure via indoor air inhalation and dust ingestion in comparison to outdoor air inhalation and dietary intake. - Although dietary intake is major human exposure route to PBDEs, there is sufficient body of evidence for the ubiquitous presence of these compounds in indoor air and dust, therefore for the potential for significant exposure at work, at home, as well as in closed means of transport.

  20. Percieved control over indoor climate and its impact on Dutch office workers

    NARCIS (Netherlands)

    Boerstra, A.C.; Loomans, M.G.L.C.; Hensen, J.L.M.; Loomans, M.G.L.C.; Kulve, te M.

    2015-01-01

    A field study was conducted in nine modern office buildings in the Netherlands. The study focused on perceived control over indoor climate and its impact on satisfaction of building occupants, the incidence of building related (SBS) symptoms and self-assessed performance. The study involved a

  1. A Robust Localization, Slip Estimation, and Compensation System for WMR in the Indoor Environments

    Directory of Open Access Journals (Sweden)

    Zakir Ullah

    2018-05-01

    Full Text Available A novel approach is proposed for the path tracking of a Wheeled Mobile Robot (WMR in the presence of an unknown lateral slip. Much of the existing work has assumed pure rolling conditions between the wheel and ground. Under the pure rolling conditions, the wheels of a WMR are supposed to roll without slipping. Complex wheel-ground interactions, acceleration and steering system noise are the factors which cause WMR wheel slip. A basic research problem in this context is localization and slip estimation of WMR from a stream of noisy sensors data when the robot is moving on a slippery surface, or moving at a high speed. DecaWave based ranging system and Particle Filter (PF are good candidates to estimate the location of WMR indoors and outdoors. Unfortunately, wheel-slip of WMR limits the ultimate performance that can be achieved by real-world implementation of the PF, because location estimation systems typically partially rely on the robot heading. A small error in the WMR heading leads to a large error in location estimation of the PF because of its cumulative nature. In order to enhance the tracking and localization performance of the PF in the environments where the main reason for an error in the PF location estimation is angular noise, two methods were used for heading estimation of the WMR (1: Reinforcement Learning (RL and (2: Location-based Heading Estimation (LHE. Trilateration is applied to DecaWave based ranging system for calculating the probable location of WMR, this noisy location along with PF current mean is used to estimate the WMR heading by using the above two methods. Beside the WMR location calculation, DecaWave based ranging system is also used to update the PF weights. The localization and tracking performance of the PF is significantly improved through incorporating heading error in localization by applying RL and LHE. Desired trajectory information is then used to develop an algorithm for extracting the lateral slip along

  2. Indoor air pollutants, ventilation rate determinants and potential control strategies in Chinese dwellings: A literature review.

    Science.gov (United States)

    Ye, Wei; Zhang, Xu; Gao, Jun; Cao, Guangyu; Zhou, Xiang; Su, Xing

    2017-05-15

    After nearly twenty years of rapid modernization and urbanization in China, huge achievements have transformed the daily lives of the Chinese people. However, unprecedented environmental consequences in both indoor and outdoor environments have accompanied this progress and have triggered public awareness and demands for improved living standards, especially in residential environments. Indoor pollution data measured for >7000 dwellings (approximately 1/3 were newly decorated and were tested for volatile organic compound (VOC) measurements, while the rest were tested for particles, phthalates and other semi-volatile organic compounds (SVOCs), moisture/mold, inorganic gases and radon) in China within the last ten years were reviewed, summarized and compared with indoor concentration recommendations based on sensory or health end-points. Ubiquitous pollutants that exceed the concentration recommendations, including particulate matter, formaldehyde, benzene and other VOCs, moisture/mold, inorganic gases and radon, were found, indicating a common indoor air quality (IAQ) issue in Chinese dwellings. With very little prevention, oral, inhalation and dermal exposure to those pollutants at unhealthy concentration levels is almost inevitable. CO 2 , VOCs, humidity and radon can serve as ventilation determinants, each with different ventilation demands and strategies, at typical occupant densities in China; and particle reduction should be a prerequisite for determining ventilation requirements. Two directional ventilation modes would have profound impacts on improving IAQ for Chinese residences are: 1) natural (or window) ventilation with an air cleaner and 2) mechanical ventilation with an air filtration unit, these two modes were reviewed and compared for their applicability and advantages and disadvantages for reducing human exposure to indoor air pollutants. In general, mode 2 can more reliably ensure good IAQ for occupants; while mode 1 is more applicable due to its

  3. A Hybrid 3D Indoor Space Model

    Directory of Open Access Journals (Sweden)

    A. Jamali

    2016-10-01

    Full Text Available GIS integrates spatial information and spatial analysis. An important example of such integration is for emergency response which requires route planning inside and outside of a building. Route planning requires detailed information related to indoor and outdoor environment. Indoor navigation network models including Geometric Network Model (GNM, Navigable Space Model, sub-division model and regular-grid model lack indoor data sources and abstraction methods. In this paper, a hybrid indoor space model is proposed. In the proposed method, 3D modeling of indoor navigation network is based on surveying control points and it is less dependent on the 3D geometrical building model. This research proposes a method of indoor space modeling for the buildings which do not have proper 2D/3D geometrical models or they lack semantic or topological information. The proposed hybrid model consists of topological, geometrical and semantical space.

  4. Airborne contamination in the indoor environment and its implications for dose

    DEFF Research Database (Denmark)

    Andersson, Kasper Grann; Roed, Jørn; Byrne, M.A.

    2004-01-01

    Previous work has indicated that radiation doses from deposition on human skin, hair and clothing may contribute significantly to the dose received after a major nuclear accident, such as that, which happened at Chernobyl in 1986. The available data was,however, sparse and associated with conside......Previous work has indicated that radiation doses from deposition on human skin, hair and clothing may contribute significantly to the dose received after a major nuclear accident, such as that, which happened at Chernobyl in 1986. The available data was,however, sparse and associated...... on the deposition of contaminant aerosol were examined, and since the previous measurements had indicated that elemental iodine could be a particularly problematiccontaminant, experimental work was additionally undertaken to examine the process of deposition of this species to skin. Since both clearance...... and percutaneous penetration of deposited contaminants could play important roles in determining doses,experimental programmes were dedicated to the identification of parameters of interest in these contexts. Also doses from contamination on different surfaces in the indoor environment have in the past...

  5. Qualitative assessment of bacteria and fungi in the indoor environment of hospitals of Islamabad, Pakistan

    International Nuclear Information System (INIS)

    Tahir, S.S.; Rauf, N.; Batool, A.

    2012-01-01

    This study was conducted to determine the health risks in the indoor air of the four government. hospitals of the Islamabad city, Pakistan. Four different main wards, i.e., general male/female surgical wards, children's ward and microbiology laboratory were included. The sampling was done in the summer season due to the possibility of maximum recovery of microorganisms. Results showed presence of bacterial and fungal pathogens in the air of hospitals especially in surgical wards of all hospitals. Lowest bacterial counts were recorded in microbiology laboratory. Among bacterial isolates Micrococcus and Staphylococcus auleus were abundantly found in all hospitals as 22.09 % and 21.2 %, respectively followed by gram negative group of bacteria i.e, Enterobacteriaceae spp. (Escherichia coil), Pseudomonas spp. were found to be lowest as 6.5 % of the total bacterial load in all hospitals. Among the fungi Aspergillus (fumigatus.niger; flavus) recovery was the most in the environment of all hospitals with the value of 27.7 % and Tricosporon was observed lowest with the value of 1.15 %. p- value for total microbial load among the hospitals sampled was not significant. (author)

  6. Challenges in Wireless System Integration as Enablers for Indoor Context Aware Environments

    Directory of Open Access Journals (Sweden)

    Peio López-Iturri

    2017-07-01

    Full Text Available The advent of fully interactive environments within Smart Cities and Smart Regions requires the use of multiple wireless systems. In the case of user-device interaction, which finds multiple applications such as Ambient Assisted Living, Intelligent Transportation Systems or Smart Grids, among others, large amount of transceivers are employed in order to achieve anytime, anyplace and any device connectivity. The resulting combination of heterogeneous wireless network exhibits fundamental limitations derived from Coverage/Capacity relations, as a function of required Quality of Service parameters, required bit rate, energy restrictions and adaptive modulation and coding schemes. In this context, inherent transceiver density poses challenges in overall system operation, given by multiple node operation which increases overall interference levels. In this work, a deterministic based analysis applied to variable density wireless sensor network operation within complex indoor scenarios is presented, as a function of topological node distribution. The extensive analysis derives interference characterizations, both for conventional transceivers as well as wearables, which provide relevant information in terms of individual node configuration as well as complete network layout.

  7. Development of an Indoor Airflow Energy Harvesting System for Building Environment Monitoring

    Directory of Open Access Journals (Sweden)

    Fei Fei

    2014-05-01

    Full Text Available Wireless sensor networks (WSNs have been widely used for intelligent building management applications. Typically, indoor environment parameters such as illumination, temperature, humidity and air quality are monitored and adjusted by an intelligent building management system. However, owing to the short life-span of the batteries used at the sensor nodes, the maintenance of such systems has been labor-intensive and time-consuming. This paper discusses a battery-less self-powering system that converts the mechanical energy from the airflow in ventilation ducts into electrical energy. The system uses a flutter energy conversion device (FECD capable of working at low airflow speeds while installed on the ventilation ducts inside of buildings. A power management strategy implemented with a circuit system ensures sufficient power for driving commercial electronic devices. For instance, the power management circuit is capable of charging a 1 F super capacitor to 2 V under ventilation duct airflow speeds of less than 3 m/s.

  8. An Improved Indoor Positioning System Using RGB-D Cameras and Wireless Networks for Use in Complex Environments

    Directory of Open Access Journals (Sweden)

    Jaime Duque Domingo

    2017-10-01

    Full Text Available This work presents an Indoor Positioning System to estimate the location of people navigating in complex indoor environments. The developed technique combines WiFi Positioning Systems and depth maps, delivering promising results in complex inhabited environments, consisting of various connected rooms, where people are freely moving. This is a non-intrusive system in which personal information about subjects is not needed and, although RGB-D cameras are installed in the sensing area, users are only required to carry their smart-phones. In this article, the methods developed to combine the above-mentioned technologies and the experiments performed to test the system are detailed. The obtained results show a significant improvement in terms of accuracy and performance with respect to previous WiFi-based solutions as well as an extension in the range of operation.

  9. Effect of Personal Control over Thermal Environment in a Laboratorium Setting

    DEFF Research Database (Denmark)

    Kulve, M. te; Boerstra, A. C.; Toftum, Jørn

    Field studies have demonstrated that personal control over the indoor climate may increase comfort and could reduce SBS symptoms. A laboratory study was performed to investigate if being in control over the thermal environment influences comfort, symptoms and performance. The central hypothesis...... was that human responses to a thermal indoor environment depend on the availability of control opportunities. This was tested in a field lab where subjects had a personal desk fan with a stepless controller at their workplace. Two conditions were tested: one (the first) with individual control and one without......, but with identical indoor climate exposure as recorded during the first session. During both experimental conditions, 23 subjects were exposed for 120 min to an operative temperature of 28 °C and they were provided with a personal desk fan. During the first exposure subjects were allowed to adjust air velocity (and...

  10. Nanomaterials for benign indoor environments: Electrochromics for 'smart windows', sensors for air quality, and photo-catalysts for air cleaning

    International Nuclear Information System (INIS)

    Granqvist, C.G.; Azens, A.; Heszler, P.; Kish, L.B.; OEsterlund, L.

    2007-01-01

    Nanomaterials can be used in a number of technologies in order to accomplish benign indoor environments. This paper takes a unified view on this problem from a solar-energy-based perspective and specifically considers electrochromics for achieving good day-lighting jointly with energy efficiency, sensors aimed at air quality assessment, and photocatalysis for air cleaning. Recent results, mainly from the authors' laboratories, are reported for all of these areas. (author)

  11. Control of the indoor climate of an electronic workshop; Beheersing binnenklimaat elektronische werkplaats

    Energy Technology Data Exchange (ETDEWEB)

    Zhi-Seng, Li; Sheng, Mei [Faculty of Construction, Guangdong University of Technology, Guangdong (China); Guo-Qiang, Zhang [Hunan University College of Civil Engineering, Hunan (China); Jian-Long, Liu [Department of Civil Engineering, Zhuzhou Institute of Technology, Zhuzhou, Hunan (China)

    2008-09-15

    A semiconductor manufacturing plant is an example of the maximum requirement for clean, dust-free interiors. A single dust particle attaching itself to wafer during fabrication will result in electronic malfunction or short-circuiting of the chip. Control over micro-contamination is therefore a primary environmental management concern in a semiconductor facility. A detailed analysis was conducted of the air contamination characteristics and environmental conditions in a microelectronics manufacturing plant. Field measurements were also taken at a semiconductor factory in southern China. Data was collected regarding the level of micro contamination and the control of the indoor environment. The study indicates that 80 percent of the contaminants originate from personnel, 15 percent from the ventilation system and 5 percent from the building materials. The concentration of dust particles clearly rises when staff members enter and leave the clean room frequently, and the indoor air quality declines strongly in relation to the number of movements made by staff. Favourable parameters for the manufacturing of microcircuit chips appear to include 50 to 60 percent relative humidity, 19-25C air temperature and a relative overpressure of at least 5 Pa. [Dutch] Een werkplaats waar chips vervaardigd worden is een voorbeeld van een ruimte waar de hoogste eisen aan de luchtzuiverheid in een ruimte worden gesteld. Voor silicone microcircuit chips geldt dat elke aanraking met een stofdeeltje leidt tot een verstoring of kortsluiting in het elektrocircuit. Dit zorgt ervoor dat de microchip zijn functie verliest. Daarom is het beheersen van de verontreinigingen het belangrijkste aspect ten aanzien van het omgevingsmanagement in een werkplaats waar semiconductor chips vervaardigd worden. De verontreinigingskarakteristieken in een dergelijke werkplaats zijn in detail geanalyseerd, daarnaast worden er ook resultaten gepresenteerd van praktijkmetingen die verricht zijn in Zuid China. Ten

  12. The Role of the Propagation Environment in RSS-Based Indoor Positioning Using Mass Market Devices

    DEFF Research Database (Denmark)

    Pelosi, Mauro; Pedersen, Gert Frølund; Della Rosa, Francescantonio

    2012-01-01

    This paper deals with the propagation channel challenges affecting indoor positioning. Several methods are reviewed and experimental results are provided, showing that the pathloss method is preferable with respect to fingerprinting because of its intrinsic complexity and uncertain effective reli...

  13. A New Localization System for Indoor Service Robots in Low Luminance and Slippery Indoor Environment Using Afocal Optical Flow Sensor Based Sensor Fusion

    Directory of Open Access Journals (Sweden)

    Dong-Hoon Yi

    2018-01-01

    Full Text Available In this paper, a new localization system utilizing afocal optical flow sensor (AOFS based sensor fusion for indoor service robots in low luminance and slippery environment is proposed, where conventional localization systems do not perform well. To accurately estimate the moving distance of a robot in a slippery environment, the robot was equipped with an AOFS along with two conventional wheel encoders. To estimate the orientation of the robot, we adopted a forward-viewing mono-camera and a gyroscope. In a very low luminance environment, it is hard to conduct conventional feature extraction and matching for localization. Instead, the interior space structure from an image and robot orientation was assessed. To enhance the appearance of image boundary, rolling guidance filter was applied after the histogram equalization. The proposed system was developed to be operable on a low-cost processor and implemented on a consumer robot. Experiments were conducted in low illumination condition of 0.1 lx and carpeted environment. The robot moved for 20 times in a 1.5 × 2.0 m square trajectory. When only wheel encoders and a gyroscope were used for robot localization, the maximum position error was 10.3 m and the maximum orientation error was 15.4°. Using the proposed system, the maximum position error and orientation error were found as 0.8 m and within 1.0°, respectively.

  14. A New Localization System for Indoor Service Robots in Low Luminance and Slippery Indoor Environment Using Afocal Optical Flow Sensor Based Sensor Fusion.

    Science.gov (United States)

    Yi, Dong-Hoon; Lee, Tae-Jae; Cho, Dong-Il Dan

    2018-01-10

    In this paper, a new localization system utilizing afocal optical flow sensor (AOFS) based sensor fusion for indoor service robots in low luminance and slippery environment is proposed, where conventional localization systems do not perform well. To accurately estimate the moving distance of a robot in a slippery environment, the robot was equipped with an AOFS along with two conventional wheel encoders. To estimate the orientation of the robot, we adopted a forward-viewing mono-camera and a gyroscope. In a very low luminance environment, it is hard to conduct conventional feature extraction and matching for localization. Instead, the interior space structure from an image and robot orientation was assessed. To enhance the appearance of image boundary, rolling guidance filter was applied after the histogram equalization. The proposed system was developed to be operable on a low-cost processor and implemented on a consumer robot. Experiments were conducted in low illumination condition of 0.1 lx and carpeted environment. The robot moved for 20 times in a 1.5 × 2.0 m square trajectory. When only wheel encoders and a gyroscope were used for robot localization, the maximum position error was 10.3 m and the maximum orientation error was 15.4°. Using the proposed system, the maximum position error and orientation error were found as 0.8 m and within 1.0°, respectively.

  15. Polluted air--outdoors and indoors.

    Science.gov (United States)

    Myers, I; Maynard, R L

    2005-09-01

    Many air pollutants which are considered important in ambient (outdoor) air are also found, sometimes at higher levels, in indoor air. With demanding standards having been set for many of these pollutants, both in the workplace and ambient air, consideration of the problems posed by indoor pollution is gaining pace. Studies on exposure to pollutants found in the indoor domestic environment are increasing and are contributing to an already significant compilation of datasets. Improvement in monitoring techniques has helped this process. Documented reports of fatalities from carbon monoxide poisonings are still worrying. However, studies on health effects of non-fatal, long term, low dose, indoor exposure to carbon monoxide and other pollutants, are still inconclusive and too infrequently documented. Of particular concern are the levels of air pollutants found in the domestic indoor environment in developing countries, despite simple interventions such as vented stoves having shown their value. Exposure to biomass smoke is still a level that would be considered unacceptable on health grounds in developed countries. As in the occupational environment, steps need to be taken to control the risks from exposure to the harmful constituents of indoor air in the home. However, the difficulty regarding regulation of the domestic indoor environment is its inherent privacy. Monitoring levels of pollutants in the home and ensuring regulations are adhered to, would likely prove difficult, especially when individual behaviour patterns and activities have the greatest influence on pollutant levels in indoor air. To this end, the Department of Health is developing guidance on indoor air pollution to encourage the reduction of pollutant levels in indoor domestic air. The importance of the effects of domestic indoor air on health and its contribution to the health of the worker are increasingly appreciated. Occupational physicians, by training and interest, are well placed to extend

  16. Health and productivity gains from better indoor environments and their implications for the U.S. Department of Energy

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, William J.

    2000-10-01

    A substantial portion of the US population suffers frequently from communicable respiratory illnesses, allergy and asthma symptoms, and sick building syndrome symptoms. We now have increasingly strong evidence that changes in building design, operation, and maintenance can significantly reduce these illnesses. Decreasing the prevalence or severity of these health effects would lead to lower health care costs, reduced sick leave, and shorter periods of illness-impaired work performance, resulting in annual economic benefits for the US in the tens of billions of dollars. Increasing the awareness of these potential health and economic gains, combined with other factors, could help bring about a shift in the way we design, construct, operate, and occupy buildings. The current goal of providing marginally adequate indoor environments could be replaced by the goal of providing indoor environments that maximize the health, satisfaction, and performance of building occupants. Through research and technology transfer, DOE and its contractors are well positioned to help stimulate this shift in practice and, consequently, improve the health and economic well-being of the US population. Additionally, DOE's energy-efficiency interests would be best served by a program that prepares for the potential shift, specifically by identifying and promoting the most energy-efficient methods of improving the indoor environment. The associated research and technology transfer topics of particular relevance to DOE are identified and discussed.

  17. Correlation between Novel Potential Indoor Risk Factors and Frequency of Doctor's Visit for Respiratory Problem in Taiwan's Tropical Environment

    Directory of Open Access Journals (Sweden)

    Yu-Hao Wang

    2018-01-01

    Full Text Available Background: With a global rising trend in prevalence of allergic diseases, more attention has been paid to investigation of environmental risk factors. Many risk factors have so far been identified. However, novel risk factors specific to Taiwanese environment and lifestyle were still relatively unknown. Objective: To investigate the potential effects of a number of little-known indoor risk factors on the frequency of doctor's visit for respiratory problems in context of Taiwanese environment and lifestyle. Methods: A cross-sectional, population-based study was performed on a 861 participants around Kaohsiung area, Taiwan. Survey investigation was employed to assess the household environment and the frequency of doctor's visit for respiratory problems. Results: Participants who performed “daily cleaning” was shown to have a significantly (p=0.007 higher mean number of doctor's visits in comparison to those who did not. Similar observation was made for participants who periodically took out beddings (p=0.042. Age had a significant positive correlation (linear regression β 0.089 with frequency of respiratory problems. Conclusion: The habit of daily cleaning was implicated as a potential indoor risk factor due to the unique nature of Taiwanese cleaning habit and close contact with cleaning supplies, which could serve as chemical irritants. Bedding takeout was predicted to be an indicator of chronic allergies rather than an actual risk factor. However, both were controversial in their role as potential indoor risk factor, and required further examination.

  18. Gender, airborne chemical monitoring, and physical work environment are related to indoor air symptoms among nonindustrial workers in the Klang Valley, Malaysia.

    Science.gov (United States)

    Syazwan, Aizat Ismail; Hafizan, Juahir; Baharudin, Mohd Rafee; Azman, Ahmad Zaid Fattah; Izwyn, Zulkapri; Zulfadhli, Ismail; Syahidatussyakirah, Katis

    2013-01-01

    The purpose of this study was to analyze the relationship of airborne chemicals and the physical work environment risk element on the indoor air symptoms of nonindustrial workers. A cross-sectional study consisting of 200 office workers. A random selection of 200 buildings was analyzed for exposure and indoor air symptoms based on a pilot study in the Klang Valley, Malaysia. A set of modified published questionnaires by the Department of Occupational Safety and Health (DOSH), Malaysia and a previous study (MM040NA questionnaire) pertaining to indoor air symptoms was used in the evaluation process of the indoor air symptoms. Statistical analyses involving logistic regression and linear regression were used to determine the relationship between exposure and indoor air symptoms for use in the development of an indoor risk matrix. The results indicate that some indoor air pollutants (carbon monoxide, formaldehyde, total volatile organic compound, and dust) are related to indoor air symptoms of men and women. Temperature and relative humidity showed a positive association with complaints related to the perceived indoor environmental condition (drafts and inconsistency of temperature). Men predominantly reported general symptoms when stratification of gender involved exposure to formaldehyde. Women reported high levels of complaints related to mucosal and general symptoms from exposure to the dust level indoors. Exposure to pollutants (total volatile organic compounds, carbon monoxide, and formaldehyde) and physical stressors (air temperature and relative humidity) influence reported symptoms of office workers. These parameters should be focused upon and graded as one of the important elements in the grading procedure when qualitatively evaluating the indoor environment.

  19. Indoor air quality

    DEFF Research Database (Denmark)

    Jensen, Trine Susanne; Recevska, Ieva

     The objective of the 35th specific agreement is to provide support to the EEA activities in Environment and Health (E&H) on the topic of indoor air quality. The specific objectives have been to provide an overview of indoor air related projects in EU and indoor air related policies as well...... as idenfiying "good practices" to reduce health impact of indoor air exposure and suggest areas for future improvements....

  20. Wireless Control of Miniaturized Mobile Vehicle for Indoor Surveillance

    International Nuclear Information System (INIS)

    Saquib, Syed M Taha; Hameed, Sarmad; Jafri, Raza; Usman Ali, Syed M; Amin, Imran

    2013-01-01

    This work is based upon electronic automation and Smart Control techniques, which constitute the basis of Control Area Network (CAN) and Personal Area Network (PAN). Bluetooth technology has been interfaced with a programmable controller to provide multi-dimensional vehicle control. A network is proposed which contains a remote, mobile host controller and an android operating system based mobile set (Client). The client communicates with a host controller through a Bluetooth device. The system incorporates duplex communication after successful confirmation between the host and the client; the android based mobile unit controls the vehicle through the Bluetooth module

  1. Measurement of air exchange rates in different indoor environments using continuous CO2 sensors

    Institute of Scientific and Technical Information of China (English)

    Yan YOU; Can Niu; Jian Zhou; Yating Liu; Zhipeng Bai; Jiefeng Zhang; Fei He; Nan Zhang

    2012-01-01

    A new air exchange rate (AER) monitoring method using continuous CO2 sensors was developed and validated through both laboratory experiments and field studies.Controlled laboratory simulation tests were conducted in a 1-m3 environmental chamber at different AERs (0.1-10.0 hr-1).AERs were determined using the decay method based on box model assumptions.Field tests were conducted in classrooms,dormitories,meeting rooms and apartments during 2-5 weekdays using CO2 sensors coupled with data loggers.Indoor temperature,relative humidity (RH),and CO2 concentrations were continuously monitored while outdoor parameters combined with on-site climate conditions were recorded.Statistical results indicated that good laboratory performance was achieved:duplicate precision was within 10%,and the measured AERs were 90%-120% of the real AERs.Average AERs were 1.22,1.37,1.10,1.91 and 0.73 hr-1 in dormitories,air-conditioned classrooms,classrooms with an air circulation cooling system,reading rooms,and meeting rooms,respectively.In an elderly particulate matter exposure study,all the homes had AER values ranging from 0.29 to 3.46 hr-1 in fall,and 0.12 to 1.39 hr-1 in winter with a median AER of 1.15.

  2. Measurement of air exchange rates in different indoor environments using continuous CO2 sensors.

    Science.gov (United States)

    You, Yan; Niu, Can; Zhou, Jian; Liu, Yating; Bai, Zhipeng; Zhang, Jiefeng; He, Fei; Zhang, Nan

    2012-01-01

    A new air exchange rate (AER) monitoring method using continuous CO2 sensors was developed and validated through both laboratory experiments and field studies. Controlled laboratory simulation tests were conducted in a 1-m3 environmental chamber at different AERs (0.1-10.0 hr(-1)). AERs were determined using the decay method based on box model assumptions. Field tests were conducted in classrooms, dormitories, meeting rooms and apartments during 2-5 weekdays using CO2 sensors coupled with data loggers. Indoor temperature, relative humidity (RH), and CO2 concentrations were continuously monitored while outdoor parameters combined with on-site climate conditions were recorded. Statistical results indicated that good laboratory performance was achieved: duplicate precision was within 10%, and the measured AERs were 90%-120% of the real AERs. Average AERs were 1.22, 1.37, 1.10, 1.91 and 0.73 hr(-1) in dormitories, air-conditioned classrooms, classrooms with an air circulation cooling system, reading rooms, and meeting rooms, respectively. In an elderly particulate matter exposure study, all the homes had AER values ranging from 0.29 to 3.46 hr(-1) in fall, and 0.12 to 1.39 hr(-1) in winter with a median AER of 1.15.

  3. Quantification of differences between occupancy and total monitoring periods for better assessment of exposure to particles in indoor environments

    Science.gov (United States)

    Wierzbicka, A.; Bohgard, M.; Pagels, J. H.; Dahl, A.; Löndahl, J.; Hussein, T.; Swietlicki, E.; Gudmundsson, A.

    2015-04-01

    For the assessment of personal exposure, information about the concentration of pollutants when people are in given indoor environments (occupancy time) are of prime importance. However this kind of data frequently is not reported. The aim of this study was to assess differences in particle characteristics between occupancy time and the total monitoring period, with the latter being the most frequently used averaging time in the published data. Seven indoor environments were selected in Sweden and Finland: an apartment, two houses, two schools, a supermarket, and a restaurant. They were assessed for particle number and mass concentrations and number size distributions. The measurements using a Scanning Mobility Particle Sizer and two photometers were conducted for seven consecutive days during winter in each location. Particle concentrations in residences and schools were, as expected, the highest during occupancy time. In the apartment average and median PM2.5 mass concentrations during the occupancy time were 29% and 17% higher, respectively compared to total monitoring period. In both schools, the average and medium values of the PM2.5 mass concentrations were on average higher during teaching hours compared to the total monitoring period by 16% and 32%, respectively. When it comes to particle number concentrations (PNC), in the apartment during occupancy, the average and median values were 33% and 58% higher, respectively than during the total monitoring period. In both houses and schools the average and median PNC were similar for the occupancy and total monitoring periods. General conclusions on the basis of measurements in the limited number of indoor environments cannot be drawn. However the results confirm a strong dependence on type and frequency of indoor activities that generate particles and site specificity. The results also indicate that the exclusion of data series during non-occupancy periods can improve the estimates of particle concentrations and

  4. Joystick-controlled video console game practice for developing power wheelchairs users' indoor driving skills.

    Science.gov (United States)

    Huang, Wei Pin; Wang, Chia Cheng; Hung, Jo Hua; Chien, Kai Chun; Liu, Wen-Yu; Cheng, Chih-Hsiu; Ng, How-Hing; Lin, Yang-Hua

    2015-02-01

    [Purpose] This study aimed to determine the effectiveness of joystick-controlled video console games in enhancing subjects' ability to control power wheelchairs. [Subjects and Methods] Twenty healthy young adults without prior experience of driving power wheelchairs were recruited. Four commercially available video games were used as training programs to practice joystick control in catching falling objects, crossing a river, tracing the route while floating on a river, and navigating through a garden maze. An indoor power wheelchair driving test, including straight lines, and right and left turns, was completed before and after the video game practice, during which electromyographic signals of the upper limbs were recorded. The paired t-test was used to compare the differences in driving performance and muscle activities before and after the intervention. [Results] Following the video game intervention, participants took significantly less time to complete the course, with less lateral deviation when turning the indoor power wheelchair. However, muscle activation in the upper limbs was not significantly affected. [Conclusion] This study demonstrates the feasibility of using joystick-controlled commercial video games to train individuals in the control of indoor power wheelchairs.

  5. A survey on distribution and toxigenicity of Aspergillus flavus from indoor and outdoor hospital environments.

    Science.gov (United States)

    Sepahvand, Asghar; Shams-Ghahfarokhi, Masoomeh; Allameh, Abdolamir; Jahanshiri, Zahra; Jamali, Mojdeh; Razzaghi-Abyaneh, Mehdi

    2011-11-01

    In the present study, genetic diversity and mycotoxin profiles of Aspergillus flavus isolated from air (indoors and outdoors), levels (surfaces), and soils of five hospitals in Southwest Iran were examined. From a total of 146 Aspergillus colonies, 63 isolates were finally identified as A. flavus by a combination of colony morphology, microscopic criteria, and mycotoxin profiles. No Aspergillus parasiticus was isolated from examined samples. Chromatographic analyses of A. flavus isolates cultured on yeast extract-sucrose broth by tip culture method showed that approximately 10% and 45% of the isolates were able to produce aflatoxin B(1) (AFB(1)) and cyclopiazonic acid (CPA), respectively. Around 40% of the isolates produced sclerotia on Czapek-Dox agar. The isolates were classified into four chemotypes based on the ability to produce AF and CPA that majority of them (55.5%) belonged to chemotype IV comprising non-mycotoxigenic isolates. Random amplified polymorphic DNA (RAPD) profiles generated by a combination of four selected primers were used to assess genetic relatedness of 16 selected toxigenic and non-toxigenic isolates. The resulting dendrogram demonstrated the formation of two separate clusters for the A. flavus comprised both mycotoxigenic and non-toxigenic isolates in a random distribution. The obtained results in this study showed that RAPD profiling is a promising and efficient tool to determine intra-specific genetic variation among A. flavus populations from hospital environments. A. flavus isolates, either toxigenic or non-toxigenic, should be considered as potential threats for hospitalized patients due to their obvious role in the etiology of nosocomial aspergillosis.

  6. Polyphasic taxonomy of Aspergillus section Aspergillus (formerly Eurotium, and its occurrence in indoor environments and food

    Directory of Open Access Journals (Sweden)

    A.J. Chen

    2017-09-01

    Full Text Available Aspergillus section Aspergillus (formerly the genus Eurotium includes xerophilic species with uniseriate conidiophores, globose to subglobose vesicles, green conidia and yellow, thin walled eurotium-like ascomata with hyaline, lenticular ascospores. In the present study, a polyphasic approach using morphological characters, extrolites, physiological characters and phylogeny was applied to investigate the taxonomy of this section. Over 500 strains from various culture collections and new isolates obtained from indoor environments and a wide range of substrates all over the world were identified using calmodulin gene sequencing. Of these, 163 isolates were subjected to molecular phylogenetic analyses using sequences of ITS rDNA, partial β-tubulin (BenA, calmodulin (CaM and RNA polymerase II second largest subunit (RPB2 genes. Colony characteristics were documented on eight cultivation media, growth parameters at three incubation temperatures were recorded and micromorphology was examined using light microscopy as well as scanning electron microscopy to illustrate and characterize each species. Many specific extrolites were extracted and identified from cultures, including echinulins, epiheveadrides, auroglaucins and anthraquinone bisanthrons, and to be consistent in strains of nearly all species. Other extrolites are species-specific, and thus valuable for identification. Several extrolites show antioxidant effects, which may be nutritionally beneficial in food and beverages. Important mycotoxins in the strict sense, such as sterigmatocystin, aflatoxins, ochratoxins, citrinin were not detected despite previous reports on their production in this section. Adopting a polyphasic approach, 31 species are recognized, including nine new species. ITS is highly conserved in this section and does not distinguish species. All species can be differentiated using CaM or RPB2 sequences. For BenA, Aspergillus brunneus and A. niveoglaucus share identical

  7. Accurate and Integrated Localization System for Indoor Environments Based on IEEE 802.11 Round-Trip Time Measurements

    Directory of Open Access Journals (Sweden)

    Alfonso Bahillo

    2010-01-01

    Full Text Available The presence of (Non line of Sight NLOS propagation paths has been considered the main drawback for localization schemes to estimate the position of a (Mobile User MU in an indoor environment. This paper presents a comprehensive wireless localization system based on (Round-Trip Time RTT measurements in an unmodified IEEE 802.11 wireless network. It overcomes the NLOS impairment by implementing the (Prior NLOS Measurements Correction PNMC technique. At first, the RTT measurements are performed with a novel electronic circuit avoiding the need for time synchronization between wireless nodes. At second, the distance between the MU and each reference device is estimated by using a simple linear regression function that best relates the RTT to the distance in (Line of Sight LOS. Assuming that LOS in an indoor environment is a simplification of reality hence, the PNMC technique is applied to correct the NLOS effect. At third, assuming known the position of the reference devices, a multilateration technique is implemented to obtain the MU position. Finally, the localization system coupled with measurements demonstrates that the system outperforms the conventional time-based indoor localization schemes without using any tracking technique such as Kalman filters or Bayesian methods.

  8. Effect of phase change materials on indoor thermal environment under different weather conditions and over a long time

    International Nuclear Information System (INIS)

    Ling, Haoshu; Chen, Chao; Wei, Shen; Guan, Yong; Ma, Caiwen; Xie, Guangya; Li, Na; Chen, Ziguang

    2015-01-01

    Highlights: • Indicators evaluating the performance of PCMs in greenhouses are introduced. • Real equivalent specific heat capacity of PCMs is embedded in a numerical model. • Real behaviour of PCMs has been monitored over a long time. • Efficiency of PCMs walls are compared for sunny and cloudy days. • Heat storage and release amounts of PCMs walls have been calculated. - Abstract: To evaluate the effect of phase change materials (PCMs) on the indoor thermal environment of greenhouses under different weather conditions and over a long time in the heating season, a study was carried out using both experimental method and numerical method. The study was conducted in a typical greenhouse located in Beijing, China, and important parameters have been monitored continuously for 61 days, including indoor air temperature, outdoor air temperature, solar radiation, surface temperature of greenhouse envelopes and soil temperature. Based on these parameters, a number of indicators, namely, operative temperature, daily effective accumulative temperature, irradiated surface temperature of the north wall, average temperature of PCMs, and daily heat storage and release, have been used to evaluate the performance of PCMs in greenhouses. All indicators have provided consistent results that confirm the positive effect of PCMs on improving the indoor thermal environment of greenhouses over a long time. Additionally, the paper has demonstrated that a sunny weather could help to promote the efficiency of PCMs, comparing to a cloudy weather

  9. The influence of a student's 'home' climate on room temperature and indoor environmental controls use in a modern halls of residence

    OpenAIRE

    Amin, Rucha; Teli, Despoina; James, Patrick; Bourikas, Leonidas

    2016-01-01

    Adaptive comfort theory states that over time people adapt to their normal environment. Therefore, people from different climates are expected to have different thermal preferences and behaviours, which could lead to ‘performance gap’ in buildings with occupants of diverse climate backgrounds. This study investigates the influence of occupants’ thermal history on use of controls and indoor temperature preference in a newly built halls of residence building complex in Southampton, UK, which pr...

  10. Exploring the relationship between structurally defined geometrical parameters of reinforced concrete beams and the thermal comfort on indoor environment

    DEFF Research Database (Denmark)

    Lee, Daniel Sang-Hoon; Naboni, Emanuele

    2017-01-01

    mass effect (and the implication on thermal comfort) and the given geometrical parameters of exposed soffit reinforced concrete beams are explored. The geometrical parameters of the beams are initially defined in means of structural optimisation. The beams consist of flange and web in likeness of T...... the resultant heat exchange behaviour, and the implication on thermal comfort indoor environment. However, the current paper presents the thermal mass characteristics of one geometrical type. The study is based on results derived from computational fluid dynamics (CFD) analysis, where Rhino 3D is used......The paper presents a research exploring the thermal mass effect of reinforced concrete beams with structurally optimised geometrical forms. Fully exposed concrete soffits in architectural contexts create more than just visual impacts on the indoor climate through their possible interferences...

  11. a Preliminary Work on Layout Slam for Reconstruction of Indoor Corridor Environments

    Science.gov (United States)

    Baligh Jahromi, A.; Sohn, G.; Shahbazi, M.; Kang, J.

    2017-09-01

    We propose a real time indoor corridor layout estimation method based on visual Simultaneous Localization and Mapping (SLAM). The proposed method adopts the Manhattan World Assumption at indoor spaces and uses the detected single image straight line segments and their corresponding orthogonal vanishing points to improve the feature matching scheme in the adopted visual SLAM system. Using the proposed real time indoor corridor layout estimation method, the system is able to build an online sparse map of structural corner point features. The challenges presented by abrupt camera rotation in the 3D space are successfully handled through matching vanishing directions of consecutive video frames on the Gaussian sphere. Using the single image based indoor layout features for initializing the system, permitted the proposed method to perform real time layout estimation and camera localization in indoor corridor areas. For layout structural corner points matching, we adopted features which are invariant under scale, translation, and rotation. We proposed a new feature matching cost function which considers both local and global context information. The cost function consists of a unary term, which measures pixel to pixel orientation differences of the matched corners, and a binary term, which measures the amount of angle differences between directly connected layout corner features. We have performed the experiments on real scenes at York University campus buildings and the available RAWSEEDS dataset. The incoming results depict that the proposed method robustly performs along with producing very limited position and orientation errors.

  12. Carbon Dioxide Detection and Indoor Air Quality Control.

    Science.gov (United States)

    Bonino, Steve

    2016-04-01

    When building ventilation is reduced, energy is saved because it is not necessary to heat or cool as much outside air. Reduced ventilation can result in higher levels of carbon dioxide, which may cause building occupants to experience symptoms. Heating or cooling for ventilation air can be enhanced by a DCV system, which can save energy while providing a comfortable environment. Carbon dioxide concentrations within a building are often used to indicate whether adequate fresh air is being supplied to the building. These DCV systems use carbon dioxide sensors in each space or in the return air and adjust the ventilation based on carbon dioxide concentration; the higher the concentration, the more people occupy the space relative to the ventilation rate. With a carbon dioxide sensor DCV system, the fresh air ventilation rate varies based on the number ofpeople in the space, saving energy while maintaining a safe and comfortable environment.

  13. Health, indoor environment and energy conservation. Letter report; Gezondheid, binnenmilieu en energiebesparing. Briefrapport

    Energy Technology Data Exchange (ETDEWEB)

    Koudijs, E.A.; Fischer, P.; Schram, D.; Knol, A.

    2011-11-15

    A literature study has examined the link between energy saving measures and improvement of the indoor climate. Based on the scientific literature, no statements can be made as to the influence on health and the costs and benefits of specific measures to improve the indoor climate. However, there does seem to be a link between the general improvement of the indoor climate or living circumstances and a decrease in existing health complaints [Dutch] In een literatuuronderzoek onderzoek is gekeken naar de koppeling van energiebesparende maatregelen en verbetering van het binnenmilieu. Op grond van de wetenschappelijke literatuur kan geen uitspraak worden gedaan over de invloed op de gezondheid en kosten/baten van specifieke maatregelen ter verbetering van het binnenmilieu. Wel lijkt algemene verbetering van het binnenmilieu of de woonomstandigheden gerelateerd te zijn aan een afname van bestaande gezondheidsklachten.

  14. Cost effectiveness analysis of indoor radon control measures

    International Nuclear Information System (INIS)

    Fujimoto, Kenzo

    1989-01-01

    The problem of radon 222 in buildings as a contributor to radiation exposure is described. Five different control methods and the dose reductions that would result from each are analysed. The annualized cost for each control measure was evaluated and the cost effectiveness of each control measure was calculated on the basis of dollars per person-sievert dose reduction. The use of unipolar ion generators for particle removal appears to be the most cost effective and the use of ceiling fans to increase air circulation the least cost effective. 3 figs., 1 tab

  15. Indoor air pollution exposure from use of indoor stoves and fireplaces in association with breast cancer: a case-control study.

    Science.gov (United States)

    White, Alexandra J; Teitelbaum, Susan L; Stellman, Steven D; Beyea, Jan; Steck, Susan E; Mordukhovich, Irina; McCarty, Kathleen M; Ahn, Jiyoung; Rossner, Pavel; Santella, Regina M; Gammon, Marilie D

    2014-12-12

    Previous studies suggest that polycyclic aromatic hydrocarbons (PAHs) may adversely affect breast cancer risk. Indoor air pollution from use of indoor stoves and/or fireplaces is an important source of ambient PAH exposure. However, the association between indoor stove/fireplace use and breast cancer risk is unknown. We hypothesized that indoor stove/fireplace use in a Long Island, New York study population would be positively associated with breast cancer and differ by material burned, and the duration and timing of exposure. We also hypothesized that the association would vary by breast cancer subtype defined by p53 mutation status, and interact with glutathione S-transferases GSTM1, T1, A1 and P1 polymorphisms. Population-based, case-control resources (1,508 cases/1,556 controls) were used to conduct unconditional logistic regression to estimate adjusted odds ratios (OR) and 95% confidence intervals (CI). Breast cancer risk was increased among women reporting ever burning synthetic logs (which may also contain wood) in their homes (OR = 1.42, 95% CI 1.11, 1.84), but not for ever burning wood alone (OR = 0.93, 95% CI 0.77, 1.12). For synthetic log use, longer duration >7 years, older age at exposure (>20 years; OR = 1.65, 95% CI 1.02, 2.67) and 2 or more variants in GSTM1, T1, A1 or P1 (OR = 1.71, 95% CI 1.09, 2.69) were associated with increased risk. Burning wood or synthetic logs are both indoor PAH exposure sources; however, positive associations were only observed for burning synthetic logs, which was stronger for longer exposures, adult exposures, and those with multiple GST variant genotypes. Therefore, our results should be interpreted with care and require replication.

  16. Distribution of indoor radon concentrations and elements of a strategy for control

    International Nuclear Information System (INIS)

    Nero, A.V. Jr.

    1986-05-01

    Indoor radon concentrations vary widely in the US housing stock, with normal concentrations estimated to cause a significant risk of lung cancer by comparison with environmental exposures normally considered, and high concentrations causing risks that exceed even those from cigarette smoking. The probability distribution, i.e., the number of houses at various concentrations, can be estimated from an analysis of the US indoor radon data accumulated to date. Such an analysis suggests that in about a million houses, occupants are receiving exposures greater than those experienced by uranium miners. The form of the frequency distribution, including not only the average concentration, but also the number of houses with high levels, has substantial influence on strategies for control of indoor radon. Such strategies require three major elements: formulation of control objectives in terms of guidelines for remedial action and for new houses; selection of means for identifying homes with high concentrations; and a framework for deciding what types of control measures are appropriate to particular circumstances and how rapidly they should be employed

  17. An Integrated Control System for Heating and Indoor Climate Applications

    DEFF Research Database (Denmark)

    Tahersima, Fatemeh

    2012-01-01

    which geothermal heat pump, solar driven heat pumps and the other types are categorized as renewable or renewable energy sources. In the present study, we investigated modeling and control of hydronic heat emitters integrated with a ground-source heat pump. Optimization of the system performance...... in terms of energy efficiency, associated energy cost and occupants’ thermal comfort is the main objective to be fulfilled via design of an integrated controller. We also proposed control strategies to manage energy consumption of the building to turn domestic heat demands into a flexible load in the smart...... in order to maximize the heat pump’s efficiency and by this means reduce the power consumption of the heat pump. The hypothesis is that such an optimal point coincides with saturation of at least one of the subsystems control valves. The idea is implemented experimentally using simple PI and on...

  18. Energy use and indoor environment in new and existing dwellings in Arctic climates

    DEFF Research Database (Denmark)

    Kotol, Martin

    2014-01-01

    on indoor air quality performed in Sisimiut, Greenland. A questionnaire as part of the study found that over 30 % of respondents experience cold discomfort during winter months (i.e. cold floors, cold draft or too low indoor temperature), 35 % of the respondents reported frequent condensation on windows...... dwellings inhabited by the questionnaire respondents. The winter measurements indicate that 73 % of the monitored bedrooms experienced average additional moisture higher than 2.5 g/kg or average night CO2 concentration above 1000 ppm and 59 % of bedrooms had experienced both. This indicates...

  19. Indoor environment in the 21st century: impact on human productivity, health and comfort

    DEFF Research Database (Denmark)

    Fanger, Povl Ole

    2002-01-01

    Although air-conditioning has played a positive role for economic development in warm climates, its image is globally mixed. Comprehensive field studies in Europe, Asia and America demonstrate that there are substantial numbers of dissatisfied people in many buildings, among them those suffering...... of excellence: better indoor air quality increases productivity and decreases SBS symptoms; unnecessary indoor pollution sources should be avoided; the air should be served cool and dry to the occupants; "personalized ventilation", i.e. small amounts of clean air, should be served gently, close to the breathing...

  20. Control in indoor radon decay products by air treatment devices

    International Nuclear Information System (INIS)

    Hinds, W.C.; Rudnick, S.N.; Maher, E.F.; First, M.W.

    1983-01-01

    An evaluation of the efficacy of household air cleaning devices as a means to control radon decay products in existing buildings is presented. Previous research on air cleaning methods for airborne radon decay products has been directed primarily to the control of radon decay products in mines and has only limited application to control in residences where dust concentration, air change rate, and humidity are lower than in mines. Results show that room size air cleaners can achieve substantial reductions in working levels in residences. Reductions observed at air infiltration rates of 0.52 air changes per hour ranged from 58 to 89%. Although the two air cleaners tested produced the greatest reductions, the low cost, simplicity, and other benefits of air circulating fans, particularly the ceiling fan, appear to make them most suitable for residences

  1. Indoor air pollution: Sources and control. July 1988-January 1990 (Citations from the NTIS data base). Report for July 1988-January 1990

    International Nuclear Information System (INIS)

    1990-01-01

    This bibliography contains citations concerning indoor air pollution in residential, commercial, industrial, and institutional buildings. Indoor air quality assessment, health hazard evaluation, and contaminant identification and measurement are discussed. Indoor air pollution control methods and equipment are evaluated. Air quality analyses of energy efficient buildings are presented. Indoor air pollution from radon and asbestos are discussed in other bibliographies. (This updated bibliography contains 75 citations, 16 of which are new entries to the previous edition.)

  2. Virtualization in control system environment

    International Nuclear Information System (INIS)

    Shen, L.R.; Liu, D.K.; Wan, T.M.

    2012-01-01

    In large scale distributed control system, there are lots of common service composed an environment for the entire control system, such as the server system for the common software base library, application server, archive server and so on. This paper gives a description of a virtualization realization for control system environment including the virtualization for server, storage, network system and application for the control system. With a virtualization instance of the EPICS based control system environment that was built by the VMware vSphere v4, we tested the whole functionality of this virtualization environment in the SSRF control system, including the common server of the NFS, NIS, NTP, Boot and EPICS base and extension library tools, we also have applied virtualization to application servers such as the Archive, Alarm, EPICS gateway and all of the network based IOC. Specially, we test the high availability and VMotion for EPICS asynchronous IOC successful under the different VLAN configuration of the current SSRF control system network. (authors)

  3. Parameter Estimation of Dynamic Multi-zone Models for Livestock Indoor Climate Control

    DEFF Research Database (Denmark)

    Wu, Zhuang; Stoustrup, Jakob; Heiselberg, Per

    2008-01-01

    , the livestock, the ventilation system and the building on the dynamic performance of indoor climate. Some significant parameters employed in the climate model as well as the airflow interaction between each conceptual zone are identified with the use of experimental time series data collected during spring......In this paper, a multi-zone modeling concept is proposed based on a simplified energy balance formulation to provide a better prediction of the indoor horizontal temperature variation inside the livestock building. The developed mathematical models reflect the influences from the weather...... and winter at a real scale livestock building in Denmark. The obtained comparative results between the measured data and the simulated output confirm that a very simple multi-zone model can capture the salient dynamical features of the climate dynamics which are needed for control purposes....

  4. Indoor Chemistry: Materials, Ventilation Systems, and Occupant Activities

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, G.C.; Corsi, R.L.; Destaillats, H.; Nazaroff, W.W.; Wells, J.R.

    2006-05-01

    Chemical processes taking place in indoor environments can significantly alter the nature and concentrations of pollutants. Exposure to secondary contaminants generated in these reactions needs to be evaluated in association with many aspects of buildings to minimize their impact on occupant health and well-being. Focusing on indoor ozone chemistry, we describe alternatives for improving indoor air quality by controlling chemical changes related to building materials, ventilation systems, and occupant activities.

  5. Small particles containing phthalic esters in the indoor environment - a pilot study

    DEFF Research Database (Denmark)

    Lundgren, B.; Bornehag, Carl-Gustaf; Cedhaim, L.

    2002-01-01

    Many chemicals in polymeric materials have low vapour pressure. Hypothetically such chemicals are emitted and may stay as particles or be adsorbed onto dust particles and become airborne. The aim of this pilot study has been to validate the methods for measuring phthalates on particles in indoor ...

  6. Airborne spread of expiratory droplet nuclei between the occupants of indoor environments: a review

    DEFF Research Database (Denmark)

    Ai, Z.T.; Melikov, Arsen Krikor

    2018-01-01

    Reynolds-averaged Navier-Stokes modelling. Future research needs in three areas are identified: the importance of the direction of indoor airflow patterns, the dynamics of airborne transmission, and the application of CFD simulations. This article is protected by copyright. All rights reserved....

  7. Measurement and apportionment of radon source terms for modeling indoor environments

    International Nuclear Information System (INIS)

    Harley, N.H.

    1990-01-01

    This research has two main goals; (1) to quantify mechanisms for radon entry into homes of different types and to determine the fraction of indoor radon attributable to each source and (2) to model and calculate the dose (and therefore alpha particle fluence) to cells in the human and animal tracheobronchial tree that is pertinent to induction of bronchogenic carcinoma from inhaled radon daughters

  8. Indoor Air Quality Tools for Schools Program: Benefits of Improving Air Quality in the School Environment.

    Science.gov (United States)

    Environmental Protection Agency, Washington, DC. Office of Radiation and Indoor Air.

    The U.S. Environmental Protection Agency (EPA) developed the Indoor Air Quality Tools for Schools (IAQ TfS) Program to help schools prevent, identify, and resolve their IAQ problems. This publication describes the program and its advantages, explaining that through simple, low-cost measures, schools can: reduce IAQ-related health risks and…

  9. Indoor radar SLAM A radar application for vision and GPS denied environments

    NARCIS (Netherlands)

    Marck, J.W.; Mohamoud, A.A.; Houwen, E.H. van de; Heijster, R.M.E.M. van

    2013-01-01

    Indoor navigation especially in unknown areas is a real challenge. Simultaneous Localization and Mapping (SLAM) technology provides a solution. However SLAM as currently based on optical sensors, is unsuitable in vision denied areas, which are for example encountered by first responders. Radar can

  10. On the Climate Variability and Energy Demands for Indoor Human Comfort Levels in Tropical Urban Environment

    Science.gov (United States)

    Pokhrel, R.; Ortiz, L. E.; González, J. E.; Ramírez-Beltran, N. D.

    2017-12-01

    The main objective of this study is to identify how climate variability influences human comfort levels in tropical urban environments. San Juan Metropolitan Area (SJMA) of the island of Puerto Rico was chosen as a reference point. A new human discomfort index (HDI) based on environmental enthalpy is defined. This index is expanded to determine the energy required to maintain indoor human comfort levels and was compared to Total Electricity consumption for the Island of Puerto Rico. Regression analysis shows that both Temperature and HDI are good indictor to predict total electrical energy consumption. Results showed that over the past 35 years the average enthalpy have increased and have mostly been above thresholds for human comfort for SJMA. The weather stations data further shows a clear indication of urbanization biases ramping up the index considered. From the trend analysis local scale (weather station) data shows a decreasing rate of maximum cooling at -11.41 kW-h/years, and minimum is increasing at 10.64 kW-h/years. To compare human comfort levels under extreme heat wave events conditions, an event of 2014 in the San Juan area was identified. The analysis for this extreme heat event is complemented by data from the National Center for environmental Prediction (NCEP) at 250km spatial resolution, North American Re-Analysis (NARR) at 32 km spatial resolution, by simulations of the Weather Forecasting System (WRF) at a resolution of 2 km, and by weather station data for San Juan. WRF simulation's results showed an improvement for both temperature and relative humidity from the input NCEP data. It also shows that difference in Energy per Capita (EPC) in urban area during a heat wave event can increase to 16% over a non-urban area. Sensitivity analysis was done by modifying the urban land cover to the most common rural references of evergreen broadleaf forest and cropland to investigate the Urban Heat Island (UHI) effect on HDI. UHI is seen to be maximum during

  11. Potential for ion-induced nucleation of volatile organic compounds by radon decay in indoor environments

    International Nuclear Information System (INIS)

    Daisey, J.M.

    1991-11-01

    There is considerable interest in the ''unattached'' fraction of radon progeny in indoor air because of its significance to the estimation of the risks of radon exposure. Because of its high mobility in air, the unattached fraction is more efficiently deposited in the respiratory tract. Variation in the diameter of the ''unattached'' fraction and in its diffusion coefficient can be due to clustering of other atmospheric species around the 218 PoO 2 + ion. The purpose of this study was to investigate the potential for the formation of clusters of vapor phase organic compounds, found in indoor air, around the 218 PoO 2 + ion and to determine which were most likely to form clusters. A secondary purpose was to provide a compilation of measurements of indoor organic compounds for future experiments and theoretical calculations by the radon research community. The classical charged liquid droplet theory (Thomson equation) was used to estimate the Gibbs free energy of ion-induced nucleation and to provide an indication of the indoor organic compounds most likely to undergo ion-induced nucleation. Forty-four volatile and semi-volatile organic compounds out of the more than 300 which have been reported in indoor air were investigated. Water vapor was included for comparison. The results indicate that there is a potential for the formation of clusters of organic compounds around the 218 PoO 2 + ion. The compounds with the greatest potential for cluster formation are the volatile oxidized hydrocarbons (e.g., n-butanol, phenol, hexanal, nonanal, benzaldehyde, the ketones and the acetates) and the semi-volatile organic compounds (pentachlorophenol, nicotine, chlordane, chlorpyrifos)

  12. Indoor air 1. Recent advances in the health science and technology

    Energy Technology Data Exchange (ETDEWEB)

    Berglund, B; Lindvall, T; Sundell, J [eds.

    1984-01-01

    Health problems and discomfort caused by a bed indoor environment is discussed. The key note adresses in the first part of this volume covers the following subjects: Future buildings and building hygiene; Sick building syndrome; Lung cancer from radon and passive smoking; Total exposure estimation; Health implications of indoor air humidity; Indoor odors; Indoor allergies; Effect of moderate thermal stress and education of thermal discomfort; Airborne infections and modern building technology, Free radicals and oxidizing agents in the indoor air; Air quality control strategies, Achievement of the superclean environment. The seecond part of this publication contains works on policy and regulatory issues.

  13. Passive design solutions to improve thermal and visual indoor environment. Case Study: University of Informatics Sciences

    International Nuclear Information System (INIS)

    González Couret, Dania; Rodríguez García, Elizabeth; González Milián, Nataly; Llovet Salazar, Mónica

    2017-01-01

    The results of a research carried out in order to improve sustainability in the University of Informatics Sciences in Havana are presented in the paper. The initial qualitative evaluation of the three more energy consumer buildings allow to identify main problems and to select indoor spaces where temperature and relative humidity were measured. Intervention proposals were elaborated which positive impact was verified by automatized simulation of results and its comparison to the departing situation. The results of the empirical research corroborate the integral qualitative evaluation carries out. It has been demonstrated that it is possible to reduce indoor temperature by modifying the envelope without high investments, if advantage is taken from benefit of green shadow. (author)

  14. Measurement and apportionment of radon source terms for modeling indoor environments

    International Nuclear Information System (INIS)

    Harley, N.H.

    1992-01-01

    This research has two main goals; (1) to quantify mechanisms for radon entry into homes of different types and to determine the fraction of indoor radon attributable to each source and (2) to model and calculate the dose (and therefore alpha particle fluence) to cells in the human and animal tracheobronchial tree that is pertinent to induction of bronchogenic carcinoma from inhaled radon daughters. The dosimetry has been extended to include organs other than the lung

  15. a Statistical Analysis on the System Performance of a Bluetooth Low Energy Indoor Positioning System in a 3d Environment

    Science.gov (United States)

    Haagmans, G. G.; Verhagen, S.; Voûte, R. L.; Verbree, E.

    2017-09-01

    Since GPS tends to fail for indoor positioning purposes, alternative methods like indoor positioning systems (IPS) based on Bluetooth low energy (BLE) are developing rapidly. Generally, IPS are deployed in environments covered with obstacles such as furniture, walls, people and electronics influencing the signal propagation. The major factor influencing the system performance and to acquire optimal positioning results is the geometry of the beacons. The geometry of the beacons is limited to the available infrastructure that can be deployed (number of beacons, basestations and tags), which leads to the following challenge: Given a limited number of beacons, where should they be placed in a specified indoor environment, such that the geometry contributes to optimal positioning results? This paper aims to propose a statistical model that is able to select the optimal configuration that satisfies the user requirements in terms of precision. The model requires the definition of a chosen 3D space (in our case 7 × 10 × 6 meter), number of beacons, possible user tag locations and a performance threshold (e.g. required precision). For any given set of beacon and receiver locations, the precision, internal- and external reliability can be determined on forehand. As validation, the modeled precision has been compared with observed precision results. The measurements have been performed with an IPS of BlooLoc at a chosen set of user tag locations for a given geometric configuration. Eventually, the model is able to select the optimal geometric configuration out of millions of possible configurations based on a performance threshold (e.g. required precision).

  16. Exposure to Air Ions in Indoor Environments: Experimental Study with Healthy Adults

    Directory of Open Access Journals (Sweden)

    Peter Wallner

    2015-11-01

    Full Text Available Since the beginning of the 20th century there has been a scientific debate about the potential effects of air ions on biological tissues, wellbeing and health. Effects on the cardiovascular and respiratory system as well as on mental health have been described. In recent years, there has been a renewed interest in this topic. In an experimental indoor setting we conducted a double-blind cross-over trial to determine if higher levels of air ions, generated by a special wall paint, affect cognitive performance, wellbeing, lung function, and cardiovascular function. Twenty healthy non-smoking volunteers (10 female, 10 male participated in the study. Levels of air ions, volatile organic compounds and indoor climate factors were determined by standardized measurement procedures. Air ions affected the autonomous nervous system (in terms of an increase of sympathetic activity accompanied by a small decrease of vagal efferent activity: In the test room with higher levels of air ions (2194/cm3 vs. 1038/cm3 a significantly higher low to high frequency ratio of the electrocardiography (ECG beat-to-beat interval spectrogram was found. Furthermore, six of nine subtests of a cognitive performance test were solved better, three of them statistically significant (verbal factor, reasoning, and perceptual speed, in the room with higher ion concentration. There was no influence of air ions on lung function and on wellbeing. Our results indicate slightly activating and cognitive performance enhancing effects of a short-term exposure to higher indoor air ion concentrations.

  17. Inverse Source Data-Processing Strategies for Radio-Frequency Localization in Indoor Environments

    Directory of Open Access Journals (Sweden)

    Gianluca Gennarelli

    2017-10-01

    Full Text Available Indoor positioning of mobile devices plays a key role in many aspects of our daily life. These include real-time people tracking and monitoring, activity recognition, emergency detection, navigation, and numerous location based services. Despite many wireless technologies and data-processing algorithms have been developed in recent years, indoor positioning is still a problem subject of intensive research. This paper deals with the active radio-frequency (RF source localization in indoor scenarios. The localization task is carried out at the physical layer thanks to receiving sensor arrays which are deployed on the border of the surveillance region to record the signal emitted by the source. The localization problem is formulated as an imaging one by taking advantage of the inverse source approach. Different measurement configurations and data-processing/fusion strategies are examined to investigate their effectiveness in terms of localization accuracy under both line-of-sight (LOS and non-line of sight (NLOS conditions. Numerical results based on full-wave synthetic data are reported to support the analysis.

  18. Wire-mesh capped deposition sensors: Novel passive tool for coarse fraction flux estimation of radon thoron progeny in indoor environments

    International Nuclear Information System (INIS)

    Mayya, Y.S.; Mishra, Rosaline; Prajith, Rama; Sapra, B.K.; Kushwaha, H.S.

    2010-01-01

    Deposition-based 222 Rn and 220 Rn progeny sensors act as unique, passive tools for determining the long time-averaged progeny deposition fluxes in the environment. The use of these deposition sensors as progeny concentration monitors was demonstrated in typical indoor environments as conceptually superior alternatives to gas-based indirect monitoring methods. In the present work, the dependency of these deposition monitors on various environmental parameters is minimized by capping the deposition sensor with a suitable wire mesh. These wire-mesh capped deposition sensors measure the coarse fraction deposition flux, which is less dependent on the change in environmental parameters like ventilation rate and turbulence. The calibration of these wire-mesh capped coarse fraction progeny sensors was carried out by laboratory controlled experiments. These sensors were deployed both in indoor and in occupational environments having widely different ventilation rates. The obtained coarse fraction deposition velocities were fairly constant in these environments, which further confirmed that the signal on the wire-mesh capped sensors show the least dependency on the change in environmental parameters. This technique has the potential to serve as a passive particle sizer in the general context of nanoparticles using progeny species as surrogates. On the whole, there exists a strong case for developing a passive system that responds only to coarse fraction for providing alternative tools for dosimetry and environmental fine particle research. - Research highlights: → Wire-mesh capped deposition sensor measures the coarse fraction deposition flux → Coarse fraction deposition flux less dependent on environmental conditions → Wire-mesh capped deposition sensor as passive particle sizer

  19. Evolving Robot Controllers for Structured Environments Through Environment Decomposition

    DEFF Research Database (Denmark)

    Moreno, Rodrigo; Faiña, Andres; Støy, Kasper

    2015-01-01

    In this paper we aim to develop a controller that allows a robot to traverse an structured environment. The approach we use is to decompose the environment into simple sub-environments that we use as basis for evolving the controller. Specifically, we decompose a narrow corridor environment...... environments and that the order in which the decomposed sub-environments are presented in sequence impacts the performance of the evolutionary algorithm....

  20. Gender, airborne chemical monitoring, and physical work environment are related to indoor air symptoms among nonindustrial workers in the Klang Valley, Malaysia

    Directory of Open Access Journals (Sweden)

    Syazwan AI

    2013-03-01

    Full Text Available Aizat Ismail Syazwan,1 Juahir Hafizan,2 Mohd Rafee Baharudin,1 Ahmad Zaid Fattah Azman,1 Zulkapri Izwyn,3 Ismail Zulfadhli,4 Katis Syahidatussyakirah11Department of Community Health, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia; 2Department of Environmental Science/Environmental Forensics Research Center (ENFORCE, Universiti Putra Malaysia, Selangor, 3Department of Biosciences and Health Science, Universiti Teknologi Malaysia; 4Faculty of Built Environment, Universiti Teknologi Malaysia, Johor, MalaysiaObjectives: The purpose of this study was to analyze the relationship of airborne chemicals and the physical work environment risk element on the indoor air symptoms of nonindustrial workers.Design: A cross-sectional study consisting of 200 office workers. A random selection of 200 buildings was analyzed for exposure and indoor air symptoms based on a pilot study in the Klang Valley, Malaysia.Methods: A set of modified published questionnaires by the Department of Occupational Safety and Health (DOSH, Malaysia and a previous study (MM040NA questionnaire pertaining to indoor air symptoms was used in the evaluation process of the indoor air symptoms. Statistical analyses involving logistic regression and linear regression were used to determine the relationship between exposure and indoor air symptoms for use in the development of an indoor risk matrix.Results: The results indicate that some indoor air pollutants (carbon monoxide, formaldehyde, total volatile organic compound, and dust are related to indoor air symptoms of men and women. Temperature and relative humidity showed a positive association with complaints related to the perceived indoor environmental condition (drafts and inconsistency of temperature. Men predominantly reported general symptoms when stratification of gender involved exposure to formaldehyde. Women reported high levels of complaints related to mucosal and general symptoms from exposure to the dust

  1. ["Assessment of indoor school environment and identification of measures to protect the respiratory health of school children and adolescents" in a sample of schools in Milan].

    Science.gov (United States)

    Piazza, S; Gulino, A; Pulvirenti, S; Vercelli, F; Carrer, P

    2012-01-01

    The management of indoor air quality in schools needs special attention because it has a strong impact on respiratory health of children with effects also on performance and social development. In Italy a prevention program for indoor environments is provided in the "Guidelines for the prevention of indoor risk factors for allergies and asthma in the school", developed by the Ministry of Health (G.U n. 9 del 13.01.11). In this context, the Ministry of Health has promoted the "Indoor school" project (CCM2010). The main objective of the project is the implementation of these guidelines. In this paper we report the results of the first phase of the project which assessed the knowledge of school principals on issues related to IAQ and building characteristics of the school.

  2. Comparison of indoor air distribution and thermal environment for different combinations of radiant heating systems with mechanical ventilation systems

    DEFF Research Database (Denmark)

    Wu, Xiaozhou; Fang, Lei; Olesen, Bjarne W.

    2018-01-01

    A hybrid system with a radiant heating system and a mechanical ventilation system, which is regarded as an advanced heating, ventilation and air-conditioning (HVAC) system, has been applied in many modern buildings worldwide. To date, almost no studies focused on comparative analysis of the indoor...... air distribution and the thermal environment for all combinations of radiant heating systems with mechanical ventilation systems. Therefore, in this article, the indoor air distribution and the thermal environment were comparatively analyzed in a room with floor heating (FH) or ceiling heating (CH......) and mixing ventilation (MV) or displacement ventilation (DV) when the supply air temperature ranged from 15.0°C to 19.0°C. The results showed that the temperature effectiveness values were 1.05–1.16 and 0.95–1.02 for MV+ FH and MV+ CH, respectively, and they were 0.78–0.91 and 0.51–0.67 for DV + FH and DV...

  3. A Middleware Based Approach to Dynamically Deploy Location Based Services onto Heterogeneous Mobile Devices Using Bluetooth in Indoor Environment

    Science.gov (United States)

    Sadhukhan, Pampa; Sen, Rijurekha; Das, Pradip K.

    Several methods for providing location based service (LBS) to mobile devices in indoor environment using wireless technologies like WLAN, RFID and Bluetooth have been proposed, implemented and evaluated. However, most of them do not focus on heterogeneity of mobile platforms, memory constraint of mobile devices, the adaptability of client or device to the new services it discovers whenever it reaches a new location. In this paper, we have proposed a Middleware based approach of LBS provision in the indoor environment, where a Bluetooth enabled Base Station (BS) detects Bluetooth enabled mobile devices and pushes a proper client application only to those devices that belong to some registered subscriber of LBS. This dynamic deployment enables the mobile clients to access any new service without having preinstalled interface to that service beforehand and thus the client's memory consumption is reduced. Our proposed work also addresses the other issues like authenticating the clients before providing them LBSs and introducing paid services. We have evaluated its performance in term of file transfer time with respect to file size and throughput with respect to distance. Experimental results on service consumption time by the mobile client for different services are also presented.

  4. INS/GPS/LiDAR Integrated Navigation System for Urban and Indoor Environments Using Hybrid Scan Matching Algorithm.

    Science.gov (United States)

    Gao, Yanbin; Liu, Shifei; Atia, Mohamed M; Noureldin, Aboelmagd

    2015-09-15

    This paper takes advantage of the complementary characteristics of Global Positioning System (GPS) and Light Detection and Ranging (LiDAR) to provide periodic corrections to Inertial Navigation System (INS) alternatively in different environmental conditions. In open sky, where GPS signals are available and LiDAR measurements are sparse, GPS is integrated with INS. Meanwhile, in confined outdoor environments and indoors, where GPS is unreliable or unavailable and LiDAR measurements are rich, LiDAR replaces GPS to integrate with INS. This paper also proposes an innovative hybrid scan matching algorithm that combines the feature-based scan matching method and Iterative Closest Point (ICP) based scan matching method. The algorithm can work and transit between two modes depending on the number of matched line features over two scans, thus achieving efficiency and robustness concurrently. Two integration schemes of INS and LiDAR with hybrid scan matching algorithm are implemented and compared. Real experiments are performed on an Unmanned Ground Vehicle (UGV) for both outdoor and indoor environments. Experimental results show that the multi-sensor integrated system can remain sub-meter navigation accuracy during the whole trajectory.

  5. Study of Noise Map and its Features in an Indoor Work Environment through GIS-Based Software

    Directory of Open Access Journals (Sweden)

    Faramarz Majidi

    2016-06-01

    Full Text Available Background: Noise mapping in industry can be useful to assess the risks of harmful noise, or to monitor noise in machine rooms. Using GIS -based software for plotting noise maps in an indoor noisy work environment can be helpful for occupational hygienists to monitor noise pollution. Methods: This study was carried out in a noisy packaging unit of a food industry in Ghazvin industrial zone, to evaluate noise levels by GIS technique. For this reason the floor of packaging unit was divided into squares of 2×2 meters and the center of each square was marked as a measurement station based on NIOSH method. The sound pressure level in each station was measured and then the measurement values were imported into Arc GIS software to plot noise map. Results: Unlike the current method, the noise maps generated by GIS technique are consistent with the nature of sound propagation. Conclusion: This study showed that for an indoor work environment, the application of GIS technology rendering the assessment of noise levels in the form of noise maps, is more realistic and more accurate than the routine method which is now being used by the occupational hygienists.

  6. Moving Horizon Control and Estimation of Livestock Ventilation Systems and Indoor Climate

    DEFF Research Database (Denmark)

    Wu, Z.; Stoustrup, Jakob; Jørgensen, John Bagterp

    2008-01-01

    In this paper, a new control strategy involves exploiting actuator redundancy in a multivariable system is developed for rejecting the covariance of the fast frequency disturbances and pursuing optimum energy solution. This strategy enhances the resilience of the control system to disturbances...... beyond its bandwidth and reduce energy consumption through on-line optimization computation. The moving horizon estimation and control (also called predictive control) technology is applied and simulated. The design is based on a coupled mathematical model which combines the hybrid ventilation system...... and the associated indoor climate for poultry in barns. The comparative simulation results illustrate the significant potential and advancement of the moving horizon methodologies in estimation and control for nonlinear Multiple Input and Multiple Output system with unknown noise covariance and actuator saturation....

  7. EU Project “School of the Future”— Refurbishment of School Buildings Toward Zero Emission with High-Performance Indoor Environment

    DEFF Research Database (Denmark)

    Erhorn-Kluttig, Heike; Erhorn, Hans; Kempe, Stephan

    2016-01-01

    :•Reduction of the total energy use > factor of 3, verified through monitoring•Reduction of the heating energy use > 75%, verified through monitoring.The improvement of the indoor environment quality (air, daylight, acoustic, thermal comfort) and the associated impact on the students’ performance will be analyzed by short......, and their primary users, namely students, i.e., the next generation, are the focus of the project. The energy and indoor environment performance of four demonstration buildings in four European countries and climates have been significantly improved due to holistic retrofits of the building envelope, their service...... and on the residential sector since the students will act as communicators to their families. Training sessions specifically tailored to their needs have improved user behavior and awareness of energy efficiency and indoor environment. The success is measured by how well the retrofits meet the following goals...

  8. Decoherence control in different environments

    International Nuclear Information System (INIS)

    Paavola, J.; Maniscalco, S.

    2010-01-01

    We investigate two techniques for controlling decoherence, focusing on the crucial role played by the environmental spectrum. We show how environments with different spectra lead to very different dynamical behaviors. Our study clearly proves that such differences must be taken into account when designing decoherence control schemes. The two techniques we consider are reservoir engineering and quantum Zeno control. We focus on a quantum harmonic oscillator initially prepared in a nonclassical state and derive analytically its non-Markovian dynamics in the presence of different bosonic thermal environments. On the one hand, we show how, by modifying the spectrum of the environment, it is possible to prolong or reduce the life of a Schroedinger cat state. On the other hand, we study the effect of nonselective energy measurements on the degradation of quantumness of initial Fock states. In this latter case, we see that the crossover between quantum Zeno and anti-Zeno effects, discussed by Maniscalco et al. [Phys. Rev. Lett. 97, 130402 (2006)], is highly sensitive to the details of the spectrum. In particular, for certain types of spectra, even very small variations of the system frequency may cause a measurement-induced acceleration of decoherence rather than its inhibition.

  9. Relative performance of indoor vector control interventions in the Ifakara and the West African experimental huts.

    Science.gov (United States)

    Oumbouke, Welbeck A; Fongnikin, Augustin; Soukou, Koffi B; Moore, Sarah J; N'Guessan, Raphael

    2017-09-19

    West African and Ifakara experimental huts are used to evaluate indoor mosquito control interventions, including spatial repellents and insecticides. The two hut types differ in size and design, so a side-by-side comparison was performed to investigate the performance of indoor interventions in the two hut designs using standard entomological outcomes: relative indoor mosquito density (deterrence), exophily (induced exit), blood-feeding and mortality of mosquitoes. Metofluthrin mosquito coils (0.00625% and 0.0097%) and Olyset® Net vs control nets (untreated, deliberately holed net) were evaluated against pyrethroid-resistant Culex quinquefasciatus in Benin. Four experimental huts were used: two West African hut designs and two Ifakara hut designs. Treatments were rotated among the huts every four nights until each treatment was tested in each hut 52 times. Volunteers rotated between huts nightly. The Ifakara huts caught a median of 37 Culex quinquefasciatus/ night, while the West African huts captured a median of 8/ night (rate ratio 3.37, 95% CI: 2.30-4.94, P  4-fold higher mosquito exit relative to the West African huts (odds ratio 4.18, 95% CI: 3.18-5.51, P < 0.0001), regardless of treatment. While blood-feeding rates were significantly higher in the West African huts, mortality appeared significantly lower for all treatments. The Ifakara hut captured more Cx. quinquefasciatus that could more easily exit into windows and eave traps after failing to blood-feed, compared to the West African hut. The higher mortality rates recorded in the Ifakara huts could be attributable to the greater proportions of Culex mosquitoes exiting and probably dying from starvation, relative to the situation in the West African huts.

  10. Estimation of electromagnetic dosimetric values from non-ionizing radiofrequency fields in an indoor commercial airplane environment.

    Science.gov (United States)

    Aguirre, Erik; Arpón, Javier; Azpilicueta, Leire; López, Peio; de Miguel, Silvia; Ramos, Victoria; Falcone, Francisco

    2014-12-01

    In this article, the impact of topology as well as morphology of a complex indoor environment such as a commercial aircraft in the estimation of dosimetric assessment is presented. By means of an in-house developed deterministic 3D ray-launching code, estimation of electric field amplitude as a function of position for the complete volume of a commercial passenger airplane is obtained. Estimation of electromagnetic field exposure in this environment is challenging, due to the complexity and size of the scenario, as well as to the large metallic content, giving rise to strong multipath components. By performing the calculation with a deterministic technique, the complete scenario can be considered with an optimized balance between accuracy and computational cost. The proposed method can aid in the assessment of electromagnetic dosimetry in the future deployment of embarked wireless systems in commercial aircraft.

  11. An approach to optimised control of HVAC systems in indoor swimming pools

    Science.gov (United States)

    Ribeiro, Eliseu M. A.; Jorge, Humberto M. M.; Quintela, Divo A. A.

    2016-04-01

    Indoor swimming pools are recognised as having a high level of energy consumption and present a great potential for energy saving. The energy is spent in several ways such as evaporation heat loss from the pool, high rates of ventilation required to guarantee the indoor air quality, and ambient temperatures with expressive values (typically 28-30°C) required to maintain conditions of comfort. This paper presents an approach to optimising control of heat ventilation and air conditioning systems that could be implemented in a building energy management system. It is easily adapted to any kind of pool and results in significant energy consumption reduction. The development and validation of the control model were carried out with a building thermal simulation software. The use of this control model in the case study building could reduce the energy efficiency index by 7.14 points (7.4% of total) which adds up to an energy cost saving of 15,609€ (7.5% of total).

  12. Measurment of radon, thoron and their progeny in indoor environment of Mohali, Punjab, Northern India, using pinhole dosimeters

    Directory of Open Access Journals (Sweden)

    Mehta Vimal

    2016-01-01

    Full Text Available The health hazards of radon and its decay products above certain levels are well known. However, for any preventive measures to be taken, we have to be aware of radon levels of that particular area. Measurement of radon and its decay products in indoor environments is an important aspect of assessing indoor air quality and health conditions associated with it. Keeping this in mind, measurements of radon, thoron and their progeny concentrations were carried out in Mohali, Northern India, using pinhole-based twin cup dosimeters. Radon exhalation rates of soil samples in the dwellings/areas were measured via an active technique of a continuous radon monitor. The indoor radon concentration in Mohali varied from 15.03 ± 0.61 Bq/m3 to 39.21 ± 1.46 Bq/m3 with an average of 26.95 Bq/m3 ,while thoron concentration in the same dwellings varied from 9.62 ± 0.54 Bq/m3 to 52.84 ± 2.77 Bq/m3 with an average of 31.09 Bq/m3. Radon progeny levels in dwellings under study varied from 1.63 to 4.24 mWL, with an average of 2.94 mWL, while thoron progeny levels varied from 0.26 to 1.43 mWL , with an average of 0.84 mWL. The annual dose received by the inhabitants of dwellings under study varied from 0.78 to 2.36 mSv, with an average of 1.61 mSv. The in situ gamma dose rate varied from 0.12 to 0.32 mSv/h.

  13. A Liquid Desiccant Cycle for Dehumidification and Fresh Water Supply in Controlled Environment Agriculture

    KAUST Repository

    Lefers, Ryan

    2017-12-01

    Controlled environment agriculture allows the production of fresh food indoors from global locations and contexts where it would not otherwise be possible. Growers in extreme climates and urban areas produce food locally indoors, saving thousands of food import miles and capitalizing upon the demand for fresh, tasty, and nutritious food. However, the growing of food, both indoors and outdoors, consumes huge quantities of water - as much as 70-80% of global fresh water supplies. The utilization of liquid desiccants in a closed indoor agriculture cycle provides the possibility of capturing plant-transpired water vapor. The regeneration/desalination of these liquid desiccants offers the potential to recover fresh water for irrigation and also to re-concentrate the desiccants for continued dehumidification. Through the utilization of solar thermal energy, the process can be completed with a very small to zero grid-energy footprint. The primary research in this dissertation focused on two areas: the dehumidification of indoor environments utilizing liquid desiccants inside membrane contactors and the regeneration of these desiccants using membrane distillation. Triple-bore PVDF hollow fiber membranes yielded dehumidification permeance rates around 0.25-0.31 g m-2 h-1 Pa-1 in lab-scale trials. A vacuum membrane distillation unit utilizing PVDF fibers yielded a flux of 2.8-7.0 kg m-2 hr-1. When the membrane contactor dehumidification system was applied in a bench scale controlled environment agriculture setup, the relative humidity levels responded dynamically to both plant transpiration and dehumidification rates, reaching dynamic equilibrium levels during day and night cycles. In addition, recovered fresh water from distillation was successfully applied for irrigation of crops and concentrated desiccants were successfully reused for dehumidification. If applied in practice, the liquid desiccant system for controlled environment agriculture offers the potential to reduce

  14. Measurement and apportionment of radon source terms for modeling indoor environments

    International Nuclear Information System (INIS)

    Harley, N.H.

    1992-01-01

    During the present 2 1/2 year contract period, we have made significant Progress in modeling the source apportionment of indoor 222 Rn and in 222 Rn decay product dosimetry. Two additional areas were worked on which we believe are useful for the DOE Radon research Program. One involved an analysis of the research house data, grouping the hourly house 222 Rn measurements into 2 day, 7 day and 90 day intervals to simulate the response of passive monitors. Another area requiring some attention resulted in a publication of 3 years of our indoor/outdoor measurements in a high-rise apartment. Little interest has been evinced in apartment measurements yet 20% of the US population lives in multiple-family dwellings, not in contact with the ground. These data together with a summary of all other published data on apartments showed that apartments have only about 50% greater 222 Rn concentration than the measured outdoor 222 Rn. Apartment dwellers generally represent a low risk group regarding 222 Rn exposure. The following sections describe the main projects in some detail

  15. Microbial Air Contamination in Indoor and Outdoor Environment of Pig Farms

    Directory of Open Access Journals (Sweden)

    Silvana Popescu

    2014-05-01

    Full Text Available Ensuring a good air quality in pig farms is important for the health of animals and human workers. The aim of this study was the assessment of the microbiological quality of the air inside the pig houses and outside of these. The study was accomplished in two pig-fattening farms in Cluj County. The microbiological air quality was assessed in the cold and warm season, by determination of the total counts of mesophilic bacteria, staphylococci, streptococci, gram-negative bacteria and fungi. The bacterial and fungal counts varied in the air of the investigated farms. In relation to the season the mean counts of bacteria and fungi were significantly higher (P 0.05 were found between the values of the parameters determined from the indoor air and those obtained outside, from a distance of 5 m from the pig houses. The numbers of the bacteria and fungi in the outdoor air lowered as the distance from the farms increased, the differences being significant at 25 and 50 m (P < 0.05. The results of the study show a high bacterial contamination of the indoor and outdoor air of the pig farms.

  16. Location-Enhanced Activity Recognition in Indoor Environments Using Off the Shelf Smart Watch Technology and BLE Beacons.

    Science.gov (United States)

    Filippoupolitis, Avgoustinos; Oliff, William; Takand, Babak; Loukas, George

    2017-05-27

    Activity recognition in indoor spaces benefits context awareness and improves the efficiency of applications related to personalised health monitoring, building energy management, security and safety. The majority of activity recognition frameworks, however, employ a network of specialised building sensors or a network of body-worn sensors. As this approach suffers with respect to practicality, we propose the use of commercial off-the-shelf devices. In this work, we design and evaluate an activity recognition system composed of a smart watch, which is enhanced with location information coming from Bluetooth Low Energy (BLE) beacons. We evaluate the performance of this approach for a variety of activities performed in an indoor laboratory environment, using four supervised machine learning algorithms. Our experimental results indicate that our location-enhanced activity recognition system is able to reach a classification accuracy ranging from 92% to 100%, while without location information classification accuracy it can drop to as low as 50% in some cases, depending on the window size chosen for data segmentation.

  17. Location-Enhanced Activity Recognition in Indoor Environments Using Off the Shelf Smart Watch Technology and BLE Beacons

    Directory of Open Access Journals (Sweden)

    Avgoustinos Filippoupolitis

    2017-05-01

    Full Text Available Activity recognition in indoor spaces benefits context awareness and improves the efficiency of applications related to personalised health monitoring, building energy management, security and safety. The majority of activity recognition frameworks, however, employ a network of specialised building sensors or a network of body-worn sensors. As this approach suffers with respect to practicality, we propose the use of commercial off-the-shelf devices. In this work, we design and evaluate an activity recognition system composed of a smart watch, which is enhanced with location information coming from Bluetooth Low Energy (BLE beacons. We evaluate the performance of this approach for a variety of activities performed in an indoor laboratory environment, using four supervised machine learning algorithms. Our experimental results indicate that our location-enhanced activity recognition system is able to reach a classification accuracy ranging from 92% to 100%, while without location information classification accuracy it can drop to as low as 50% in some cases, depending on the window size chosen for data segmentation.

  18. A Depth Video Sensor-Based Life-Logging Human Activity Recognition System for Elderly Care in Smart Indoor Environments

    Directory of Open Access Journals (Sweden)

    Ahmad Jalal

    2014-07-01

    Full Text Available Recent advancements in depth video sensors technologies have made human activity recognition (HAR realizable for elderly monitoring applications. Although conventional HAR utilizes RGB video sensors, HAR could be greatly improved with depth video sensors which produce depth or distance information. In this paper, a depth-based life logging HAR system is designed to recognize the daily activities of elderly people and turn these environments into an intelligent living space. Initially, a depth imaging sensor is used to capture depth silhouettes. Based on these silhouettes, human skeletons with joint information are produced which are further used for activity recognition and generating their life logs. The life-logging system is divided into two processes. Firstly, the training system includes data collection using a depth camera, feature extraction and training for each activity via Hidden Markov Models. Secondly, after training, the recognition engine starts to recognize the learned activities and produces life logs. The system was evaluated using life logging features against principal component and independent component features and achieved satisfactory recognition rates against the conventional approaches. Experiments conducted on the smart indoor activity datasets and the MSRDailyActivity3D dataset show promising results. The proposed system is directly applicable to any elderly monitoring system, such as monitoring healthcare problems for elderly people, or examining the indoor activities of people at home, office or hospital.

  19. A depth video sensor-based life-logging human activity recognition system for elderly care in smart indoor environments.

    Science.gov (United States)

    Jalal, Ahmad; Kamal, Shaharyar; Kim, Daijin

    2014-07-02

    Recent advancements in depth video sensors technologies have made human activity recognition (HAR) realizable for elderly monitoring applications. Although conventional HAR utilizes RGB video sensors, HAR could be greatly improved with depth video sensors which produce depth or distance information. In this paper, a depth-based life logging HAR system is designed to recognize the daily activities of elderly people and turn these environments into an intelligent living space. Initially, a depth imaging sensor is used to capture depth silhouettes. Based on these silhouettes, human skeletons with joint information are produced which are further used for activity recognition and generating their life logs. The life-logging system is divided into two processes. Firstly, the training system includes data collection using a depth camera, feature extraction and training for each activity via Hidden Markov Models. Secondly, after training, the recognition engine starts to recognize the learned activities and produces life logs. The system was evaluated using life logging features against principal component and independent component features and achieved satisfactory recognition rates against the conventional approaches. Experiments conducted on the smart indoor activity datasets and the MSRDailyActivity3D dataset show promising results. The proposed system is directly applicable to any elderly monitoring system, such as monitoring healthcare problems for elderly people, or examining the indoor activities of people at home, office or hospital.

  20. Scientific production on indoor air quality of environments used for physical exercise and sports practice: Bibliometric analysis.

    Science.gov (United States)

    Andrade, Alexandro; Dominski, Fábio Hech; Coimbra, Danilo Reis

    2017-07-01

    In order to minimize adverse health effects and increase the benefits of physical activity, it is important to systematize indoor air quality study in environments used for physical exercise and sports. To investigate and analyze the scientific production related to indoor air quality of environments used for physical exercise and sports practice through a bibliometric analysis. The databases Scielo, Science Direct, Scopus, Lilacs, Medline via Pubmed, and SportDiscus were searched from their inception to March 2016. Bibliometric analysis was performed for authors, institutions, countries, and collaborative networks, in relation to publication year, theme, citation network, funding agency, and analysis of titles and keywords of publications. Country, area, and impact factor of the journals were analyzed. Of 1281 studies screened, 34 satisfied the inclusion criteria. The first publication occurred in 1975. An increase in publications was observed in the last 15 years. Most of the studies were performed by researchers in the USA, followed by Portugal and Italy. Seventeen different scientific journals have published studies on the subject, and most are in the area of Environmental Sciences. It was noted that the categories of author keywords associated with "Pollutants," "Sport Environment," and "Physical Exercise" were the most commonly used in most studies. A total of 68% of the studies had at least one funding agency, and 81% of studies published in the last decade had funding. Our results demonstrate that there is recent exponential growth, driven in the last decade by researchers in environmental science from European institutions. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Health effects and sources of indoor air pollution. Part I

    International Nuclear Information System (INIS)

    Samet, J.M.; Marbury, M.C.; Spengler, J.D.

    1987-01-01

    Since the early 1970s, the health effects of indoor air pollution have been investigated with increasing intensity. Consequently, a large body of literature is now available on diverse aspects of indoor air pollution: sources, concentrations, health effects, engineering, and policy. This review begins with a review of the principal pollutants found in indoor environments and their sources. Subsequently, exposure to indoor air pollutants and health effects are considered, with an emphasis on those indoor air quality problems of greatest concern at present: passive exposure to tobacco smoke, nitrogen dioxide from gas-fueled cooking stoves, formaldehyde exposure, radon daughter exposure, and the diverse health problems encountered by workers in newer sealed office buildings. The review concludes by briefly addressing assessment of indoor air quality, control technology, research needs, and clinical implications. 243 references

  2. Polybrominated diphenyl ethers (PBDEs) in the indoor environment and associations with prenatal exposure

    DEFF Research Database (Denmark)

    Vorkamp, Katrin; Thomsen, Marianne; Frederiksen, Marie

    2011-01-01

    As part of a larger exposure study, samples of dust and indoor air were collected in the homes of 43 pregnant women living in the Copenhagen area (Denmark) and analysed for 12 polybrominated diphenyl ethers using GC-MS. A second dust sample collected after delivery was analysed for BDE-183 and BDE...... established geographical differences between continental Europe and North America. Additional octa- and nonaBDE congeners (BDE-197, BDE-203, BDE-206, BDE-207, and BDE-208) were analysed in dust and analytical issues were discussed as these congeners also can be a product of thermal degradation of BDE-209...... further in this study. For all matrices, the PBDE profile resembled that of the technical product Bromkal 70-5DE, but air contained higher percentages of the lower brominated congeners and placenta tissue was dominated by BDE-153. The predominance of BDE-153 has been described in other studies on human...

  3. Future timber house. Energy efficient with good indoor environment; Framtidens traehus. Energieffektiva med god innemiljoe

    Energy Technology Data Exchange (ETDEWEB)

    Kildsgaard, Ivana; Prejer, Erik

    2011-07-01

    The report presents documentation of the critical points during the development, planning, and building phases of the first multi-storey apartment buildings built in timber prefabricated construction according to the voluntary Swedish passive house criteria. Besides choice of the construction details, building elements, and technical systems the report includes results from blower-door tests as well as the energy analysis of building's heating needs and achieved summer indoor temperatures. Finally a comparison was done with a reference building Limnologen, which was built according to the energy requirements in the Vaelle Broar area in Vaexjoe. Simulations show that the Southern Portvakten building has 33 % less power need for heating than if the same building was built as the Limnologen building, while the heating demand is 41 % lower. A program for following the energy performance of the building during the first year in operation is also presented. Energy simulations were done in the DEROBLTH program.

  4. Seat-integrated localized ventilation for exposure reduction to air pollutants in indoor environments

    DEFF Research Database (Denmark)

    Bivolarova, Mariya Petrova; Rezgals, Lauris; Melikov, Arsen Krikor

    2016-01-01

    A novel ventilation method for minimizing the spread of bioeffluent contaminants generated from sedentary people indoors was developed and studied. The concept of the method consists of a ventilated cushion which is able to suck the human bioeffluents at the area of the body where they are mainly...... generated before they disperse around a room. The polluted near the body air is exhausted into the cushion and it is removed from the room by a separate exhaust system. The performance of the method was studied in series of experiments. Full-scale room and a dressed thermal manikin sitting in front....... The experiments were conducted at 26°C room air temperature. The performance of the VC in conjunction with mixing total-volume background ventilation at 1 air change per hour (ACH) was compared with that of mixing background ventilation alone operating at 1, 1.5, 3 and 6 ACH. Experiments at exhaust airflow rate...

  5. Indoor environmental risk factors in young asthmatics: a case-control study.

    Science.gov (United States)

    Lindfors, A; Wickman, M; Hedlin, G; Pershagen, G; Rietz, H; Nordvall, S L

    1995-11-01

    One hundred and ninety three children with asthma and 318 controls aged 1-4 years were evaluated for atopic heredity and exposure to possible indoor risk factors for asthma-for example exposure to furred pets, tobacco smoke, and home dampness. A subgroup of cases were classified as cat and/or dog allergic on the basis of skin prick tests. Heredity for asthma was a significant risk factor (odds ratio (OR) 3.0, confidence interval (CI) 2.1 to 4.6). Environmental tobacco smoke was associated with an excess risk for asthma (OR 1.7, CI 1.1 to 2.3) and signs of home dampness tended to increase this risk (OR 1.3, CI 0.9 to 2.0). High dose exposure to cat and/or dog resulted in an increased risk only in asthma cases sensitised to cat and/or dog (OR 2.7, CI 1.0 to 7.3). A combination of high dose exposure to cat and/or dog, environmental tobacco smoke and damp housing was associated with an OR of 8.0 (CI 1.9 to 34.1). Raised indoor humidity has been shown to reflect low air exchange, which may also lead to increased doses of inhaled aeroallergens and tobacco smoke, and contribute to the interaction between the three risk factors.

  6. A Wearable Wireless Sensor Network for Indoor Smart Environment Monitoring in Safety Applications.

    Science.gov (United States)

    Antolín, Diego; Medrano, Nicolás; Calvo, Belén; Pérez, Francisco

    2017-02-14

    This paper presents the implementation of a wearable wireless sensor network aimed at monitoring harmful gases in industrial environments. The proposed solution is based on a customized wearable sensor node using a low-power low-rate wireless personal area network (LR-WPAN) communications protocol, which as a first approach measures CO₂ concentration, and employs different low power strategies for appropriate energy handling which is essential to achieving long battery life. These wearables nodes are connected to a deployed static network and a web-based application allows data storage, remote control and monitoring of the complete network. Therefore, a complete and versatile remote web application with a locally implemented decision-making system is accomplished, which allows early detection of hazardous situations for exposed workers.

  7. A Wearable Wireless Sensor Network for Indoor Smart Environment Monitoring in Safety Applications

    Directory of Open Access Journals (Sweden)

    Diego Antolín

    2017-02-01

    Full Text Available This paper presents the implementation of a wearable wireless sensor network aimed at monitoring harmful gases in industrial environments. The proposed solution is based on a customized wearable sensor node using a low-power low-rate wireless personal area network (LR-WPAN communications protocol, which as a first approach measures CO2 concentration, and employs different low power strategies for appropriate energy handling which is essential to achieving long battery life. These wearables nodes are connected to a deployed static network and a web-based application allows data storage, remote control and monitoring of the complete network. Therefore, a complete and versatile remote web application with a locally implemented decision-making system is accomplished, which allows early detection of hazardous situations for exposed workers.

  8. Temperature and Humidity Control in Air-Conditioned Buildings with lower Energy Demand and increased Indoor Air Quality

    DEFF Research Database (Denmark)

    Paul, Joachim; Martos, E. T.

    2003-01-01

    Air-conditioning is not only a matter of temperature control. Thermal comfort and good indoor air quality are mainly a matter of humidity. Human health and well being may suffer seriously from inadequate humidity and/or too low temperatures in a room. A case study involving supermarket air......%. For indoor air temperature and humidity control, the use of an ice slurry (´Binary Ice´)was compared to conventional chilled water. The use of Binary Ice instead of chilled water makes the air handling and air distribution installation much simpler, recirculation of air becomes obsolete, and a higher portion...... of ambient air can be supplied, thus improving the indoor air quality still further. Reheating of air is not necessary when using Binary Ice. The introduction of chilled air into a room requires a different type of air outlet, however. When using Binary Ice, energy savings are high for climates with low...

  9. Ventilation and health in non-industrial indoor environments: report from a European Multidisciplinary Scientific Consensus Meeting (EUROVEN)

    DEFF Research Database (Denmark)

    Wargocki, Pawel; Sundell, Jan; Bischof, W.

    2002-01-01

    Scientific literature on the effects of ventilation on health, comfort, and productivity in non-industrial indoor environments (offices, schools, homes, etc.) has been reviewed by a multidisciplinary group of European scientists, called EUROVEN, with expertise in medicine, epidemiology, toxicology......, and engineering. The group reviewed 105 papers published in peer-reviewed scientific journals and judged 30 as conclusive, providing sufficient information on ventilation, health effects, data processing, and reporting, 14 as providing relevant background information on the issue, 43 as relevant but non......-informative or inconclusive, and 18 as irrelevant for the issue discussed. Based on the data in papers judged conclusive, the group agreed that ventilation is strongly associated with comfort (perceived air quality) and health (Sick Building Syndrome (SBS) symptoms, inflammation, infections, asthma, allergy, short-term sick...

  10. Evaluation of indoor aerosol control devices and their effects on radon progeny concentrations

    International Nuclear Information System (INIS)

    Sextro, R.G.; Offerman, F.J.; Nazaroff, W.W.; Nero, A.V.; Revzan, K.; Yater, J.

    1984-01-01

    Eleven portable air cleaing devices have been evaluated for control of indoor concentrations of respirable particles, and their concomitant effects on radon progeny concentrations have been investigated. Of the devices we examined the electrostatic precipitators and extended surface filters had significant particle removal rates, while the particle removal rates for several small panel-filters, an ion-generator, and a pair of mixing fans were found to be negligible. The evaluation of radon progeny control produced similar results; the air cleaners which were effective in removing particles were also effective in reducing radon progeny concentrations. Futhermore, at the low particle concentrations, plateout of the unattached radon progeny was found to be a significant removal mechanism. The overall removal rates due to deposition of attached and unattached progeny have been estimated from these data, and the equilibrium factors for total and unattached progeny concentrations have been calculated as a function of particle concentration. (Author)

  11. Control of Single-room Ventilation with Regenerative Heat Recovery for Indoor Climate and Energy Performance

    DEFF Research Database (Denmark)

    Smith, Kevin Michael; Svendsen, Svend

    2016-01-01

    constructions and will soon require 85%. The development of single-room ventilation units may aim for these requirements as a result. The exhaust temperatures in highly efficient heat exchangers may approach outdoor levels. The cold exhaust cannot contain ample moisture, so vapour will condense on the heat...... exchanger. Available literature suggests that uncoated rotary heat exchangers transfer this condensate to the supply air, so the drying capacity of the ventilation system may be severely limited. This could raise indoor relative humidities to unsafe levels, which could promote the growth of dust......-mites and mould. Controls may increase drying capacity by increasing ventilation airflow, but this may not be sufficient to limit moisture-related risks. This research investigated the added demand-control measure of reducing variable heat recovery to increase drying capacity when using an uncoated rotary heat...

  12. Evaluation of indoor aerosol control devices and their effects on radon progeny concentrations

    International Nuclear Information System (INIS)

    Sextro, R.G.; Offermann, F.J.; Nazaroff, W.W.; Nero, A.V.; Revzan, K.L.; Yater, J.

    1984-02-01

    Eleven portable air cleaning devices have been evaluated for control of indoor concentrations of respirable particles, and their concomitant effects on radon progeny concentrations have been investigated. Of the devices we examined the electrostatic precipitators and extended surface filters had significant particle removal rates, while the particle removal rates for several small panel-filters, an ion-generator, and a pair of mixing fans were found to be negligible. The evaluation of radon progeny control produced similar results; the air cleaners which were effective in removing particles were also effective in reducing radon progeny concentrations. Furthermore, at the low particle concentrations, plateout of the unattached radon progeny was found to be a significant removal mechanism. The overall removal rates due to deposition of attached and unattached progeny have been estimated from these data, and the equilibrium factors for total and unattached progeny concentrations have been calculated as a function of particle concentration. 7 references, 2 figures

  13. Indoor air pollution

    International Nuclear Information System (INIS)

    Spengler, J.D.

    1985-01-01

    Although official efforts to control air pollution have traditionally focused on outdoor air, it is now apparent that elevated contaminant concentrations are common inside some private and public buildings. Concerns about potential public health problems due to indoor air pollution are based on evidence that urban residents typically spend more than 90 percent of their time indoors, concentrations of some contaminants are higher indoors than outdoors, and for some pollutants personal exposures are not characterized adequately by outdoor measurements. Among the more important indoor contaminants associated with health or irritation effects are passive tobacco smoke, radon decay products, carbon monoxide, nitrogen dioxide, formaldehyde, asbestos fibers, microorganisms and aeroallergens. Efforts to assess health risks associated with indoor air pollution are limited by insufficient information about the number of people exposed, the pattern and severity of exposures, and the health consequences of exposures. An overall strategy should be developed to investigate indoor exposures, health effects, control options, and public policy alternatives

  14. Evaluation of indoor thermal environment with improved 65 nodes thermoreguration model; Kairyogata 65 bunkatsu taion chosetsu model wo mochiita shashitsunai onnetsu kankyo hyoka

    Energy Technology Data Exchange (ETDEWEB)

    Matsunaga, K; Sudo, F [Isuzu Motors Ltd., Tokyo (Japan); Tanabe, S [Ochanomizu Univ., Tokyo (Japan)

    1997-10-01

    Indoor thermal environment of a vehicle was evaluated by a numerical simulation. A numerical simulation using the equivalent temperature measured with the thermal manikin was conducted. Numerical manikin was improved and convective and radiative heat transfer at each body surface was described in detail. Comparative examination using the calculation results by the numerical simulation was also conducted. 3 refs., 8 figs., 2 tabs.

  15. A methodology for modeling photocatalytic reactors for indoor pollution control using previously estimated kinetic parameters

    Energy Technology Data Exchange (ETDEWEB)

    Passalia, Claudio; Alfano, Orlando M. [INTEC - Instituto de Desarrollo Tecnologico para la Industria Quimica, CONICET - UNL, Gueemes 3450, 3000 Santa Fe (Argentina); FICH - Departamento de Medio Ambiente, Facultad de Ingenieria y Ciencias Hidricas, Universidad Nacional del Litoral, Ciudad Universitaria, 3000 Santa Fe (Argentina); Brandi, Rodolfo J., E-mail: rbrandi@santafe-conicet.gov.ar [INTEC - Instituto de Desarrollo Tecnologico para la Industria Quimica, CONICET - UNL, Gueemes 3450, 3000 Santa Fe (Argentina); FICH - Departamento de Medio Ambiente, Facultad de Ingenieria y Ciencias Hidricas, Universidad Nacional del Litoral, Ciudad Universitaria, 3000 Santa Fe (Argentina)

    2012-04-15

    Highlights: Black-Right-Pointing-Pointer Indoor pollution control via photocatalytic reactors. Black-Right-Pointing-Pointer Scaling-up methodology based on previously determined mechanistic kinetics. Black-Right-Pointing-Pointer Radiation interchange model between catalytic walls using configuration factors. Black-Right-Pointing-Pointer Modeling and experimental validation of a complex geometry photocatalytic reactor. - Abstract: A methodology for modeling photocatalytic reactors for their application in indoor air pollution control is carried out. The methodology implies, firstly, the determination of intrinsic reaction kinetics for the removal of formaldehyde. This is achieved by means of a simple geometry, continuous reactor operating under kinetic control regime and steady state. The kinetic parameters were estimated from experimental data by means of a nonlinear optimization algorithm. The second step was the application of the obtained kinetic parameters to a very different photoreactor configuration. In this case, the reactor is a corrugated wall type using nanosize TiO{sub 2} as catalyst irradiated by UV lamps that provided a spatially uniform radiation field. The radiative transfer within the reactor was modeled through a superficial emission model for the lamps, the ray tracing method and the computation of view factors. The velocity and concentration fields were evaluated by means of a commercial CFD tool (Fluent 12) where the radiation model was introduced externally. The results of the model were compared experimentally in a corrugated wall, bench scale reactor constructed in the laboratory. The overall pollutant conversion showed good agreement between model predictions and experiments, with a root mean square error less than 4%.

  16. Assessment and determinants of airborne bacterial and fungal concentrations in different indoor environments: Homes, child day-care centres, primary schools and elderly care centres

    Science.gov (United States)

    Madureira, Joana; Paciência, Inês; Rufo, João Cavaleiro; Pereira, Cristiana; Teixeira, João Paulo; de Oliveira Fernandes, Eduardo

    2015-05-01

    Until now the influence of risk factors resulting from exposure to biological agents in indoor air has been far less studied than outdoor pollution; therefore the uncertainty of health risks, and how to effectively prevent these, remains. This study aimed (i) to quantify airborne cultivable bacterial and fungal concentrations in four different types of indoor environment as well as to identify the recovered fungi; (ii) to assess the impact of outdoor bacterial and fungal concentrations on indoor air; (iii) to investigate the influence of carbon dioxide (CO2), temperature and relative humidity on bacterial and fungal concentrations; and (iv) to estimate bacterial and fungal dose rate for children (3-5 years old and 8-10 years old) in comparison with the elderly. Air samples were collected in 68 homes, 9 child day-care centres, 20 primary schools and 22 elderly care centres, in a total of 264 rooms with a microbiological air sampler and using tryptic soy agar and malt extract agar culture media for bacteria and fungi growth, respectively. For each building, one outdoor representative location were identified and simultaneously studied. The results showed that child day-care centres were the indoor microenvironment with the highest median bacterial and fungal concentrations (3870 CFU/m3 and 415 CFU/m3, respectively), whereas the lowest median concentrations were observed in elderly care centres (222 CFU/m3 and 180 CFU/m3, respectively). Indoor bacterial concentrations were significantly higher than outdoor concentrations (p < 0.05); whereas the indoor/outdoor ratios for the obtained fungal concentrations were approximately around the unit. Indoor CO2 levels were associated with the bacterial concentration, probably due to occupancy and insufficient ventilation. Penicillium and Cladosporium were the most frequently occurring fungi. Children's had two times higher dose rate to biological pollutants when compared to adult individuals. Thus, due to children

  17. Channel Characteristics and Performance of MIMO E-SDM Systems in an Indoor Time-Varying Fading Environment

    Directory of Open Access Journals (Sweden)

    Huu Phu Bui

    2010-01-01

    Full Text Available Multiple-input multiple-output (MIMO systems employ advanced signal processing techniques. However, the performance is affected by propagation environments and antenna characteristics. The main contributions of the paper are to investigate Doppler spectrum based on measured data in a typical meeting room and to evaluate the performance of MIMO systems based on an eigenbeam-space division multiplexing (E-SDM technique in an indoor time-varying fading environment, which has various distributions of scatterers, line-of-sight wave existence, and mutual coupling effect among antennas. We confirm that due to the mutual coupling among antennas, patterns of antenna elements are changed and different from an omnidirectional one of a single antenna. Results based on the measured channel data in our measurement campaigns show that received power, channel autocorrelation, and Doppler spectrum are dependent not only on the direction of terminal motion but also on the antenna configuration. Even in the obstructed-line-of-sight environment, observed Doppler spectrum is quite different from the theoretical U-shaped Jakes one. In addition, it has been also shown that a channel change during the time interval between the transmit weight matrix determination and the actual data transmission can degrade the performance of MIMO E-SDM systems.

  18. Ensuring Healthy American Indian Generations for Tomorrow through Safe and Healthy Indoor Environments

    Science.gov (United States)

    Pacheco, Joseph A.; Pacheco, Christina M.; Lewis, Charley; Williams, Chandler; Barnes, Charles; Rosenwasser, Lanny; Choi, Won S.; Daley, Christine M.

    2015-01-01

    American Indians (AI) have the highest rate of severe physical housing problems in the U.S. (3.9%). Little information exists about the environmental hazards in AI homes. The purposes of this paper are to discuss challenges that were encountered when recruiting AI for a home-and employment-based environmental health assessments, highlight major successes, and propose recommendations for future indoor environmental health studies. The Center for American Indian Community Health (CAICH) and Children’s Mercy Hospital’s Center for Environmental Health and Allergy and Immunology Research Lab collaborated to provide educational sessions and healthy home assessments for AI. Through educational trainings, more than 240 AI were trained on the primary causes of health problems in homes. A total of 72 homes and places of employment were assessed by AI environmental health specialists. The top three categories with the most concerns observed in the homes/places of employment were allergens/dust (98%), safety/injury (89%) and chemical exposure (82%). While some information on smoking inside the home was collected, these numbers may have been underreported due to stigma. This was CAICH’s first endeavor in environmental health and although challenges arose, many more successes were achieved. PMID:25749318

  19. Modeling-gas phase reactions in indoor environments using computational fluid dynamics

    DEFF Research Database (Denmark)

    Sørensen, Dan Nørtoft; Weschler, Charles J.

    2002-01-01

    This CFD modeling study examines the concentrations of two gaseous compounds that react in an indoor setting to produce a hypothetical product. The reactants are ozone and either d-limonene or alpha-terpinene (which reacts with ozone about 40 times faster than d-limonene). In addition to two...... different terpenes, the scenarios include two air exchange rates (0.5 and 2.0 h(-1)). The terpene is introduced as a floor source with an emission pattern similar to a floor-care product. These four scenarios have been set in a fairly large two-dimensional room (13.6 x 40.6 m) with a supply at the top...... of the left wall and an exhaust at the bottom of the right wall. The room has been deliberately scaled so that the Reynolds numbers for key flow regimes match those of a room in which the calculated flow field has been validated against measured data. It has been further assumed that ozone interacts with room...

  20. Investigations into the indoor environment and respiratory health in Boston public housing.

    Science.gov (United States)

    Hynes, H Patricia; Brugge, Doug; Osgood, Neal-Dra; Snell, John; Vallarino, Jose; Spengler, John

    2004-01-01

    The self-reported prevalence of asthma in the United States increased by 75% from 1980 to 1994, a trend found to be significant and evident in every region of the country. The increase was most marked in children from birth to 14 years of age; and growing evidence indicates that, as with lead poisoning, inner-city and urban populations are most at risk. Attention has turned to the role of indoor environmental risk factors, especially in homes and schools. Such factors include moisture and mold growth, pest infestation, dust mites, the building envelope, heating systems, inadequate ventilation, nitrogen dioxide, and environmental tobacco smoke. The Healthy Public Housing Initiative (HPHI) is a Boston-based community-centered research and intervention project designed to engage Boston Housing Authority residents in a collaborative process to improve respiratory health, quality of life, building conditions, and building maintenance in public housing. This article summarizes the significant research findings from four pilot studies in housing developments that laid the foundation for the larger HPHI asthma-related environmental intervention study. The research design for the pilot projects is informed by principles of community-collaborative research. The strengths of this model of research for our work are also discussed.

  1. An assessment of ecological and case-control methods for estimating lung cancer risk due to indoor radon

    International Nuclear Information System (INIS)

    Stidley, C.A.; Samet, J.M.

    1992-01-01

    Studies of underground miners indicate that indoor radon is an important cause of lung cancer. This finding has raised concern that exposure to radon also causes lung cancer in the general population. Epidemiological studies, including both case-control and ecological approaches, have directly addressed the risks of indoor residential radon; many more case-control studies are in progress. Ecological studies that associate lung-cancer rates with typical indoor radon levels in various geographic areas have not consistently shown positive associations. The results of purportedly negative ecological studies have been used as a basis for questioning the hazards of indoor radon exposure. Because of potentially serious methodologic flaws for testing hypotheses, we examined the ecological method as a tool for assessing lung-cancer risk from indoor radon exposure. We developed a simulation approach that utilizes the Environmental Protection Agency (EPA) radon survey data to assign exposures to individuals within counties. Using the computer-generated data, we compared risk estimates obtained by ecological regression methods with those obtained from other regression methods and with the open-quotes trueclose quotes risks used to generate the data. For many of these simulations, the ecological models, while fitting the summary data well, gave risk estimates that differed considerably from the true risks. For some models, the risk estimates were negatively correlated with exposure, although the assumed relationship was positive. Attempts to improve the ecological models by adding smoking variables, including interaction terms, did not always improve the estimates of risk, which are easily affected by model misspecification. Because exposure situations used in the simulations are realistic, our results show that ecological methods may not accurately estimate the lung-cancer risk associated with indoor radon exposure

  2. Evolution of the indoor biome.

    Science.gov (United States)

    Martin, Laura J; Adams, Rachel I; Bateman, Ashley; Bik, Holly M; Hawks, John; Hird, Sarah M; Hughes, David; Kembel, Steven W; Kinney, Kerry; Kolokotronis, Sergios-Orestis; Levy, Gabriel; McClain, Craig; Meadow, James F; Medina, Raul F; Mhuireach, Gwynne; Moreau, Corrie S; Munshi-South, Jason; Nichols, Lauren M; Palmer, Clare; Popova, Laura; Schal, Coby; Täubel, Martin; Trautwein, Michelle; Ugalde, Juan A; Dunn, Robert R

    2015-04-01

    Few biologists have studied the evolutionary processes at work in indoor environments. Yet indoor environments comprise approximately 0.5% of ice-free land area--an area as large as the subtropical coniferous forest biome. Here we review the emerging subfield of 'indoor biome' studies. After defining the indoor biome and tracing its deep history, we discuss some of its evolutionary dimensions. We restrict our examples to the species found in human houses--a subset of the environments constituting the indoor biome--and offer preliminary hypotheses to advance the study of indoor evolution. Studies of the indoor biome are situated at the intersection of evolutionary ecology, anthropology, architecture, and human ecology and are well suited for citizen science projects, public outreach, and large-scale international collaborations. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. The use of long-lived 222Rn decay products (LRnD) as natural tracers in the indoor environment

    International Nuclear Information System (INIS)

    Samuelsson, C.

    1998-01-01

    In the radioactive decay chain following 222 Rn (radon) the first long-lived product 210 Pb (t 1/2 = 22.3 y) acts like a stopper and its decay products can be utilized as integrators of passed radon gas levels and a tracer reflecting long-term aerosol particle deposition processes. Long-term integration is feasible only if the LRnD activity is hidden away from the destructive practices of everyday life, such as cleaning and refurbishing. Three type of LRnD hide away places (traps) can be identified: i) Inside the human body, ii) Inside porous volumes, and iii) In surface implants. The volume trap (ii) is advantageous as it is a pure radon gas detector and as such not influenced by the indoor aerosol conditions. The drawbacks are that suitable samples is difficult to find and that tedious radio chemistry is mandatory. Alpha-recoil implanted LRnD activity (iii) into hard surfaces is the only type of trap that is suitable for large-scale retrospective measurements and the main emphasis of this contribution will be on implanted activity. Fortunately, cheap in-situ track-etch methods are now available for specific detection of implanted 210 Po into flat glass surfaces. In the ongoing Swedish non-smoker radon study only samples older than 20 years are accepted and a tentative calibration factor of 0.84 Bq.m -2 of implanted 210 Po per kBq.y.m -3 radon gas exposure is used. The aim of this contribution is to draw attention to a fairly recent field of application in the radon indoor environment, where long-lived radon daughter are used to indicate past radon concentration levels

  4. The impact of mass transfer limitations on size distributions of particle associated SVOCs in outdoor and indoor environments

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Cong; Zhang, Yinping [Department of Building Science, Tsinghua University, Beijing (China); Weschler, Charles J., E-mail: weschlch@rwjms.rutgers.edu [Department of Building Science, Tsinghua University, Beijing (China); Environmental and Occupational Health Sciences Institute, Rutgers University, Piscataway, NJ (United States); International Center for Indoor Environment and Energy, Technical University of Denmark, Lyngby (Denmark)

    2014-11-01

    Semi-volatile organic compounds (SVOCs) partition between the gas phase and airborne particles. The size distribution of particle-associated SVOCs impacts their fate in outdoor and indoor environments, as well as human exposure to these compounds and subsequent health risks. Allen et al. (1996) previously proposed that the rate of mass transfer can impact polycyclic aromatic hydrocarbon (PAH) partitioning among different sized particles, especially for time scales relevant to urban aerosols. The present study quantitatively builds on this idea, presenting a model that incorporates dynamic SVOC/particle interaction and applying this model to typical outdoor and indoor scenarios. The model indicates that the impact of mass transfer limitations on the size distribution of a particle-associated SVOC can be evaluated by the ratio of the time to achieve gas–particle equilibrium relative to the residence time of particles. The higher this ratio, the greater the influence of mass transfer limitations on the size distribution of particle-associated SVOCs. The influence of such constraints is largest on the fraction of particle-associated SVOCs in the coarse mode (> 2 μm). Predictions from the model have been found to be in reasonable agreement with size distributions measured for PAHs at roadside and suburban locations in Japan. The model also quantitatively explains shifts in the size distributions of particle associated SVOCs compared to those for particle mass, and the manner in which these shifts vary with temperature and an SVOC's molecular weight. - Highlights: • Rate of mass transfer can impact SVOC partitioning among different sized particles. • Model was developed that incorporates dynamic SVOC/particle sorption. • Key parameters: mass-transfer coefficients, partition coefficient, residence time • Model explains observed SVOC size distribution shifts with temperature and MW. • Largest impact of mass transfer constraints: SVOC sorption to coarse

  5. Dynamic modeling of human thermal comfort after the transition from an indoor to an outdoor hot environment.

    Science.gov (United States)

    Katavoutas, George; Flocas, Helena A; Matzarakis, Andreas

    2015-02-01

    Thermal comfort under non-steady-state conditions primarily deals with rapid environmental transients and significant alterations of the meteorological conditions, activity, or clothing pattern within the time scale of some minutes. In such cases, thermal history plays an important role in respect to time, and thus, a dynamic approach is appropriate. The present study aims to investigate the dynamic thermal adaptation process of a human individual, after his transition from a typical indoor climate to an outdoor hot environment. Three scenarios of thermal transients have been considered for a range of hot outdoor environmental conditions, employing the dynamic two-node IMEM model. The differences among them concern the radiation field, the activity level, and the body position. The temporal pattern of body temperatures as well as the range of skin wettedness and of water loss have been investigated and compared among the scenarios and the environmental conditions considered. The structure and the temporal course of human energy fluxes as well as the identification of the contribution of body temperatures to energy fluxes have also been studied and compared. In general, the simulation results indicate that the response of a person, coming from the same neutral indoor climate, varies depending on the scenario followed by the individual while being outdoors. The combination of radiation field (shade or not) with the kind of activity (sitting or walking) and the outdoor conditions differentiates significantly the thermal state of the human body. Therefore, 75% of the skin wettedness values do not exceed the thermal comfort limit at rest for a sitting individual under the shade. This percentage decreases dramatically, less than 25%, under direct solar radiation and exceeds 75% for a walking person under direct solar radiation.

  6. Variability of radon and thoron equilibrium factors in indoor environment of Garhwal Himalaya

    International Nuclear Information System (INIS)

    Prasad, Mukesh; Rawat, Mukesh; Dangwal, Anoop; Kandari, Tushar; Gusain, G.S.; Mishra, Rosaline; Ramola, R.C.

    2016-01-01

    The measurements of radon, thoron and their progeny concentrations have been carried out in the dwellings of Uttarkashi and Tehri districts of Garhwal Himalaya, India using LR-115 detector based pin-hole dosimeter and DRPS/DTPS techniques. The equilibrium factors for radon, thoron and their progeny were calculated by using the values measured with these techniques. The average values of equilibrium factor between radon and its progeny have been found to be 0.44, 0.39, 0.39 and 0.28 for rainy, autumn, winter and summer seasons, respectively. For thoron and its progeny, the average values of equilibrium factor have been found to be 0.04, 0.04, 0.04 and 0.03 for rainy, autumn, winter and summer seasons, respectively. The equilibrium factor between radon and its progeny has been found to be dependent on the seasonal changes. However, the equilibrium factor for thoron and progeny has been found to be same for rainy, autumn and winter seasons but slightly different for summer season. The annual average equilibrium factors for radon and thoron have been found to vary from 0.23 to 0.80 with an average of 0.42 and from 0.01 to 0.29 with an average of 0.07, respectively. The detailed discussion of the measurement techniques and the explanation for the results obtained is given in the paper. - Highlights: • Equilibrium factors for indoor radon, thoron and their progeny were measured. • Recently developed passive detector techniques were used for measurements. • The values of equilibrium factors are comparable with world's average values. • Equilibrium factor should be measured separately for individual dwelling. • Separate values of equilibrium factors are useful to produce actual radiation dose.

  7. Models for retrospective quantification of indoor radon exposure in case-control studies

    International Nuclear Information System (INIS)

    Gerken, M.; Kreienbrock, L.; Wellmann, J.; Kreuzer, M.; Wichmann, H.E.

    2000-01-01

    In epidemiologic studies on lung cancer risk due to indoor radon the quantification of individual radon exposure over a long time period is one of the main issues. Therefore, radon measurements in one or more dwellings, which in total have been inhabited by the participants for a sufficient time-period, are necessary as well as consideration of changes of building characteristics and ventilation habits, which influence radon concentration. Given data on 1-y alpha-track measurements and personal information from 6,000 participants of case-control studies in West and East Germany, and improved method is developed to assess individual radon exposure histories. Times spent in different rooms of the dwelling, which are known from a personal questionnaire, are taken into account. The time spent outside the house varies substantially among the participants. Therefore, assuming a substantially lower radon exposure outside the dwelling, the residence time constitutes an important aspect of total radon exposure. By means of an analysis of variance, important determinants of indoor radon are identified, namely constant conditions such as type of house, type of construction, year of construction, floor and type of basement, and changeable conditions such as heating system, window insulation, and airing habits. A correction of measurements in former dwellings by factors derived from the analysis is applied if current living conditions differ from those of the participants at the time when they were living in the particular dwellings. In rare cases the adjustment for changes leads to a correction of the measurements with a factor of about 1.4, but a reduction of 5% on average only. Exposure assessment can be improved by considering time at home and changes of building and ventilation conditions that affect radon concentration. The major concern that changes in ventilation habits and building conditions lead to substantial errors in exposure assessment cannot be confirmed in the

  8. A Study on Public Opinion Poll and Policy on Indoor Air Pollution

    Energy Technology Data Exchange (ETDEWEB)

    Kim, K.S.; Lee, H.S.; Kong, S.Y.; Ku, H.J. [Korea Environment Institute, Seoul (Korea)

    2001-12-01

    The purpose of this study is to review previous studies on indoor air pollution and to propose national strategies and policy measures for protecting public health from indoor air pollution based on the results of public survey research. Indoor air has the potential to be polluted by hazardous materials that might lead to serious health problems. It is well known that the indoor spaces are more polluted than outdoor ones, which can be a major health problem for those that live in urban areas who spend most of their time indoors. In Korea, studies on indoor air pollution are usually conducted under the auspices of academic research, which only focus on particular types of indoor spaces and certain concepts of indoor air quality. Thus, at present, the studies on the policies or policy measures concerning indoor air quality management are difficult to find in the country. The governmental agencies that are presently involved in the management of indoor air quality include: the Ministry of Health and Welfare, Ministry of Construction and Transportation, Ministry of Education and Human Resources Development, and Ministry of Environment. However, due to differing regulatory standards between the concerned agencies, the national management of indoor air quality has so far proven to be ineffective. Although the Ministry of Environment recently proposed a law to manage indoor air quality, it is only focuses on managing particular types of indoor spaces not regulated by other governmental bodies and is not effective in the effort towards a national managing system for indoor air pollution. According to a survey conducted by the Korea Environment Institute (KEI), the residents of the Seoul metropolitan area have been felt that environmental pollution negatively affects their health, and especially consider outdoor air pollution to be the most harmful type of pollution. Although these urban residents spend more than 20 hours a day indoors, the survey shows that they do not

  9. Smartphone-Based Indoor Integrated WiFi/MEMS Positioning Algorithm in a Multi-Floor Environment

    Directory of Open Access Journals (Sweden)

    Zengshan Tian

    2015-03-01

    Full Text Available Indoor positioning in a multi-floor environment by using a smartphone is considered in this paper. The positioning accuracy and robustness of WiFi fingerprinting-based positioning are limited due to the unexpected variation of WiFi measurements between floors. On this basis, we propose a novel smartphone-based integrated WiFi/MEMS positioning algorithm based on the robust extended Kalman filter (EKF. The proposed algorithm first relies on the gait detection approach and quaternion algorithm to estimate the velocity and heading angles of the target. Second, the velocity and heading angles, together with the results of WiFi fingerprinting-based positioning, are considered as the input of the robust EKF for the sake of conducting two-dimensional (2D positioning. Third, the proposed algorithm calculates the height of the target by using the real-time recorded barometer and geographic data. Finally, the experimental results show that the proposed algorithm achieves the positioning accuracy with root mean square errors (RMSEs less than 1 m in an actual multi-floor environment.

  10. P-marking of indoor environment and energy use. Handbook at the prospect of certification of energy use; P-maerkt innemiljoe och energianvaendning. Handbok infoer certifiering av energianvaendning

    Energy Technology Data Exchange (ETDEWEB)

    Wahlstroem, Aasa

    2005-12-15

    SP Swedish Testing and Research Institute's P-marking quality assurance scheme for buildings, products, services etc., now includes P-marking of indoor environment and energy use performance in buildings. The rules for the system, which cover new buildings, renovation and existing buildings, are set out in SP's certification rules no. SPCR 114E, specifying requirements in respect of both energy use and indoor environment management. Over the last ten years, SP has carried out considerable work in the field of the indoor environment, resulting in the development of a quality assurance system concentrating on achieving a high quality indoor environment. This quality assurance system has been successfully applied to schools, offices and dwellings. However, the performance of a building is determined not only by a good indoor environment, but also by low impact on the external environment as a result of energy use in the building. In some cases, concentrating on either good indoor environment or energy efficiency may result in an adverse effect on the other aspect, and so the quality assurance system for indoor environments been extended with a section dealing with energy use. This document is a handbook for inspection of documentation concerning quality assurance of energy use (primary energy analysis, determination of energy targets, energy management systems etc.). It can also be helpful when drawing up checklists for the organisation that is applying for P-marking. The book concentrates on requirements for approved certification of energy use in connection with P-marking of indoor environments and energy use in existing buildings: it does not cover requirements for certification of indoor environments. It starts by describing targeting, aims and requirements for P-marking of energy use, followed by presentation of some examples of inspections of collected documentation.

  11. Indoor air pollution

    International Nuclear Information System (INIS)

    Qureshi, I.H.

    2001-01-01

    Indoor air pollution is a potential risk to human health. Prolonged exposure to indoor pollutants may cause various infectious, allergic and other diseases. Indoor pollutants can emanate from a broad array of internal and external sources. Internal sources include building and furnishing materials, consumer and commercial products, office equipment, micro-organisms, pesticides and human occupants activities. External sources include soil, water supplies and outside makeup air. The main indoor air pollutants of concern are inorganic gases, formaldehyde and other volatile organic compounds, pesticides, radon and its daughters, particulates and microbes. The magnitude of human exposure to indoor pollutants can be estimated or predicted with the help of mathematical models which have been developed using the data from source emission testing and field monitoring of pollutants. In order to minimize human exposure to indoor pollutants, many countries have formulated guidelines / standards for the maximum permissible levels of main pollutants. Acceptable indoor air quality can be achieved by controlling indoor pollution sources and by effective ventilation system for removal of indoor pollutants. (author)

  12. Using a Ventilation Controller to Optimize Residential Passive Ventilation For Energy and Indoor Air Quality

    Energy Technology Data Exchange (ETDEWEB)

    Turner, William [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Walker, Iain [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2014-08-01

    One way to reduce the energy impact of providing residential ventilation is to use passive and hybrid systems. However, these passive and hybrid (sometimes called mixed-mode) systems must still meet chronic and acute health standards for ventilation. This study uses a computer simulation approach to examine the energy and indoor air quality (IAQ) implications of passive and hybrid ventilation systems, in 16 California climate zones. Both uncontrolled and flow controlled passive stacks are assessed. A new hybrid ventilation system is outlined that uses an intelligent ventilation controller to minimise energy use, while ensuring chronic and acute IAQ standards are met. ASHRAE Standard 62.2-2010 – the United States standard for residential ventilation - is used as the chronic standard, and exposure limits for PM2.5, formaldehyde and NO2 are used as the acute standards.The results show that controlled passive ventilation and hybrid ventilation can be used in homes to provide equivalent IAQ to continuous mechanical ventilation, for less use of energy.

  13. A nursing home staff tool for the indoor visual environment : the content validity

    NARCIS (Netherlands)

    Sinoo, M.M.; Kort, H.S.M.; Loomans, M.G.L.C.; Schols, J.M.G.A.

    2016-01-01

    In the Netherlands, over 40% of nursing home residents are estimated to have visual impairments. This results in the loss of basic visual abilities. The nursing home environment fits more or less to residents’ activities and social participation. This is referred to as environmental fit. To raise

  14. A nursing home staff tool for the indoor visual environment: The content validity

    NARCIS (Netherlands)

    Marcel G.L.C. Loomans; Dr. H.S.M. Kort; Marianne M. Sinoo; Jos M.G.A Schols

    2016-01-01

    In the Netherlands, over 40% of nursing home residents are estimated to have visual impairments. This results in the loss of basic visual abilities. The nursing home environment fits more or less to residents’ activities and social participation. This is referred to as environmental fit. To raise

  15. Evaluation of indoor aerosol control devices and their effects on radon progeny concentrations. Revision

    International Nuclear Information System (INIS)

    Sextro, R.G.; Offermann, F.J.; Nazaroff, W.W.; Nero, A.V.; Revzan, K.L.; Yater, J.

    1984-11-01

    Eleven portable air cleaning devices have been evaluated for control of indoor concentrations of respirable particles, and their concomitant effects on radon progeny concentrations have been investigated. The experiments were conducted in a room-size chamber using cigarette smoke and radon injection from an external source. Of the devices examined the electrostatic precipitators and extended surface filters had significant particle removal rates, while the particle removal rates for several small panel-filters, an ion-generator, and a pair of mixing fans were found to be essentially negligible. The evaluation of radon progeny control produced similar results; the air cleaners which were effective in removing particles were also effective in reducing radon progeny concentrations. At the low particle concentrations, deposition of the unattached radon progeny on room surfaces was found to be a significant removal mechanism. Deposition rates of attached and unattached progeny have been estimated from these data, and were used to calculate the equilibrium factors for total and unattached progeny concentrations as a function of particle concentration. While particle removal reduces total airborne radon progeny concentrations, the relative alpha decay dose to the lungs appears to change very little as the particle concentration decreases due to the greater radiological importance of unattached progeny

  16. Aerosol Emissions from Fuse-Deposition Modeling 3D Printers in a Chamber and in Real Indoor Environments.

    Science.gov (United States)

    Vance, Marina E; Pegues, Valerie; Van Montfrans, Schuyler; Leng, Weinan; Marr, Linsey C

    2017-09-05

    Three-dimensional (3D) printers are known to emit aerosols, but questions remain about their composition and the fundamental processes driving emissions. The objective of this work was to characterize the aerosol emissions from the operation of a fuse-deposition modeling 3D printer. We modeled the time- and size-resolved emissions of submicrometer aerosols from the printer in a chamber study, gained insight into the chemical composition of emitted aerosols using Raman spectroscopy, and measured the potential for exposure to the aerosols generated by 3D printers under real-use conditions in a variety of indoor environments. The average aerosol emission rates ranged from ∼10 8 to ∼10 11 particles min -1 , and the rates varied over the course of a print job. Acrylonitrile butadiene styrene (ABS) filaments generated the largest number of aerosols, and wood-infused polylactic acid (PLA) filaments generated the smallest amount. The emission factors ranged from 6 × 10 8 to 6 × 10 11 per gram of printed part, depending on the type of filament used. For ABS, the Raman spectra of the filament and the printed part were indistinguishable, while the aerosol spectra lacked important peaks corresponding to styrene and acrylonitrile, which are both present in ABS. This observation suggests that aerosols are not a result of volatilization and subsequent nucleation of ABS or direct release of ABS aerosols.

  17. "Where does the damp come from?" Investigations into the indoor environment and respiratory health in Boston public housing.

    Science.gov (United States)

    Hynes, H Patricia; Brugge, Doug; Osgood, Neal-Dra; Snell, John; Vallarino, Jose; Spengler, John

    2003-01-01

    The self-reported prevalence of asthma increased by 75% from 1980 to 1994, a trend found to be significant and evident in every region of the country. The increase has been most marked in children 0-14 years of age, and there is evidence that, as with lead poisoning, inner-city and urban populations are most at risk. Attention has turned to the role of indoor environment risk factors, especially in homes and schools. Such factors include moisture and mold growth, pest infestation, dust mites, the building envelope, heating systems, inadequate ventilation, NO2, and environmental tobacco smoke. The Healthy Public Housing Initiative (HPHI) is a Boston-based community-centered research and intervention project designed to engage Boston Housing Authority residents in a collaborative process to improve respiratory health, quality of life, building conditions, and building maintenance in public housing. This article summarizes the significant research findings from four pilot studies in housing developments that lay the foundation for the larger HPHI asthma-related environmental intervention study. The research design for the pilot projects is informed by principles of community-collaborative research. The strengths of this model of research to our work are also discussed.

  18. THE RELATIONSHIP BETWEEN SOCIAL, POLICY AND PHYSICAL VENUE FEATURES AND SOCIAL COHESION ON CONDOM USE FOR PREGNANCY PREVENTION AMONG SEX WORKERS: A SAFER INDOOR WORK ENVIRONMENT SCALE

    Science.gov (United States)

    Duff, Putu; Shoveller, Jean; Dobrer, Sabina; Ogilvie, Gina; Montaner, Julio; Chettiar, Jill; Shannon, Kate

    2015-01-01

    Background This study aims to: report on a newly developed ‘Safer Indoor Work Environmental Scale’ that characterizes the social, policy and physical features of indoor venues and social cohesion; and using this scale, longitudinally evaluate the association between these features on sex workers’ (SWs’) condom use for pregnancy prevention. Methods Drawing on a prospective open cohort of female SWs working in indoor venues, a newly-developed ‘Safer Indoor Work Environment Scale’ was used to build six multivariable models with generalized estimating equations (GEE), to determine the independent effects of social, policy and venue-based features and social cohesion on condom use. Results Of 588 indoor SWs, 63.6% used condoms for pregnancy prevention in the last month. In multivariable GEE analysis, the following venue-based features were significantly correlated with barrier contraceptive use for pregnancy prevention: managerial practices and venue safety policies (Adjusted Odds Ratio (AOR)=1.09; 95% Confidence Interval (95%CI) 1.01–1.17) access to sexual and reproductive health services/supplies (AOR=1.10; 95%CI 1.00–1.20) access to drug harm reduction (AOR=1.13; 95%CI 1.01–1.28), and social cohesion among workers (AOR=1.05; 95%CI 1.03–1.07). Access to security features was marginally associated with condom use (AOR=1.13; 95%CI 0.99–1.29). Conclusion The findings of the current study highlight how work environment and social cohesion among SWs are related to improved condom use. Given global calls for the decriminalization of sex work, and potential legislative reforms in Canada, this study points to the critical need for new institutional arrangements (e.g., legal and regulatory frameworks; labour standards) to support safer sex workplaces. PMID:25678713

  19. The relationship between social, policy and physical venue features and social cohesion on condom use for pregnancy prevention among sex workers: a safer indoor work environment scale.

    Science.gov (United States)

    Duff, Putu; Shoveller, Jean; Dobrer, Sabina; Ogilvie, Gina; Montaner, Julio; Chettiar, Jill; Shannon, Kate

    2015-07-01

    This study aims to report on a newly developed Safer Indoor Work Environmental Scale that characterises the social, policy and physical features of indoor venues and social cohesion; and using this scale, longitudinally evaluate the association between these features on sex workers' (SWs') condom use for pregnancy prevention. Drawing on a prospective open cohort of female SWs working in indoor venues, a newly developed Safer Indoor Work Environment Scale was used to build six multivariable models with generalised estimating equations (GEE), to determine the independent effects of social, policy and physical venue-based features and social cohesion on condom use. Of 588 indoor SWs, 63.6% used condoms for pregnancy prevention in the last month. In multivariable GEE analysis, the following venue-based features were significantly correlated with barrier contraceptive use for pregnancy prevention: managerial practices and venue safety policies (adjusted OR (AOR)=1.09; 95% CI 1.01 to 1.17), access to sexual and reproductive health services/supplies (AOR=1.10; 95% CI 1.00 to 1.20), access to drug harm reduction (AOR=1.13; 95% CI 1.01 to 1.28) and social cohesion among workers (AOR=1.05; 95% CI 1.03 to 1.07). Access to security features was marginally associated with condom use (AOR=1.13; 95% CI 0.99 to 1.29). The findings of the current study highlight how work environment and social cohesion among SWs are related to improved condom use. Given global calls for the decriminalisation of sex work, and potential legislative reforms in Canada, this study points to the critical need for new institutional arrangements (eg, legal and regulatory frameworks; labour standards) to support safer sex workplaces. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  20. Flexible Access Control for Dynamic Collaborative Environments

    NARCIS (Netherlands)

    Dekker, M.A.C.

    2009-01-01

    Access control is used in computer systems to control access to confidential data. In this thesis we focus on access control for dynamic collaborative environments where multiple users and systems access and exchange data in an ad hoc manner. In such environments it is difficult to protect

  1. Monitoring airborne biotic contaminants in the indoor environment of pig and poultry confinement buildings.

    Science.gov (United States)

    Hong, Pei-Ying; Li, Xiangzhen; Yang, Xufei; Shinkai, Takumi; Zhang, Yuanhui; Wang, Xinlei; Mackie, Roderick I

    2012-06-01

    Given the growing concerns over human and animal health issues related to confined animal feeding operations, an in-depth examination is required to monitor for airborne bacteria and associated antibiotic resistance genes. Our 16S rRNA-based pyrosequencing revealed that the airborne microbial community skewed towards a higher abundance of Firmicutes (> 59.2%) and Bacteroidetes (4.2-31.4%) within the confinement buildings, while the office environment was predominated by Proteobacteria (55.2%). Furthermore, bioaerosols in the confinement buildings were sporadically associated with genera of potential pathogens, and these genera were more frequently observed in the bioaerosols of pig and layer hen confinement than the turkey confinement buildings and office environment. High abundances of tetracycline resistance genes (9.55 × 10(2) to 1.69 × 10(6) copies ng(-1) DNA) were also detected in the bioaerosols sampled from confinement buildings. Bacterial lineages present in the poultry bioaerosols clustered apart from those present in the pig bioaerosols and among the different phases of pig production, suggesting that different livestock as well as production phase were associated with a distinct airborne microbial community. By understanding the diversity of biotic contaminants associated with the different confinement buildings, this study facilitates the implementation of better management strategies to minimize potential health impacts on both livestock and humans working in this environment. © 2012 Society for Applied Microbiology and Blackwell Publishing Ltd.

  2. Current Indoor Air Quality in Japan.

    Science.gov (United States)

    Jinno, Hideto

    2016-01-01

    People spend more than two thirds of their daily time indoors. Hence, maintaining a healthy indoor environment is indispensable for the prevention of building related illness. In Japan, guidelines for indoor air quality have been established for 13 volatile/semi-volatile organic compounds (VOCs/SVOCs). These guidelines are now under revision by the Committee on Sick House Syndrome: Indoor Air Pollution. In order to gain information on the current indoor air pollutants and their levels, we carried out a nation-wide survey of VOCs and aldehydes in indoor residential air during 2012-2013. In this review, I concisely summarized the current indoor air quality of Japan.

  3. An indoor chemical cocktail

    Science.gov (United States)

    Gligorovski, Sasho; Abbatt, Jonathan P. D.

    2018-02-01

    In the past 50 years, many of the contaminants and chemical transformations that occur in outdoor waters, soils, and air have been elucidated. However, the chemistry of the indoor environment in which we live most of the time—up to 90% in some societies—is not nearly as well studied. Recent work has highlighted the wealth of chemical transformations that occur indoors. This chemistry is associated with 3 of the top 10 risk factors for negative health outcomes globally: household air pollution from solid fuels, tobacco smoking, and ambient particulate matter pollution (1). Assessments of human exposure to indoor pollutants must take these reactive processes into consideration.

  4. Efficient Time-Domain Ray-Tracing Technique for the Analysis of Ultra-Wideband Indoor Environments including Lossy Materials and Multiple Effects

    Directory of Open Access Journals (Sweden)

    F. Saez de Adana

    2009-01-01

    Full Text Available This paper presents an efficient application of the Time-Domain Uniform Theory of Diffraction (TD-UTD for the analysis of Ultra-Wideband (UWB mobile communications for indoor environments. The classical TD-UTD formulation is modified to include the contribution of lossy materials and multiple-ray interactions with the environment. The electromagnetic analysis is combined with a ray-tracing acceleration technique to treat realistic and complex environments. The validity of this method is tested with measurements performed inside the Polytechnic building of the University of Alcala and shows good performance of the model for the analysis of UWB propagation.

  5. Indoor navigation by image recognition

    Science.gov (United States)

    Choi, Io Teng; Leong, Chi Chong; Hong, Ka Wo; Pun, Chi-Man

    2017-07-01

    With the progress of smartphones hardware, it is simple on smartphone using image recognition technique such as face detection. In addition, indoor navigation system development is much slower than outdoor navigation system. Hence, this research proves a usage of image recognition technique for navigation in indoor environment. In this paper, we introduced an indoor navigation application that uses the indoor environment features to locate user's location and a route calculating algorithm to generate an appropriate path for user. The application is implemented on Android smartphone rather than iPhone. Yet, the application design can also be applied on iOS because the design is implemented without using special features only for Android. We found that digital navigation system provides better and clearer location information than paper map. Also, the indoor environment is ideal for Image recognition processing. Hence, the results motivate us to design an indoor navigation system using image recognition.

  6. Indoor location system based on discriminant-adaptive neural network in IEEE 802.11 environments.

    Science.gov (United States)

    Fang, Shih-Hau; Lin, Tsung-Nan

    2008-11-01

    This brief paper presents a novel localization algorithm, named discriminant-adaptive neural network (DANN), which takes the received signal strength (RSS) from the access points (APs) as inputs to infer the client position in the wireless local area network (LAN) environment. We extract the useful information into discriminative components (DCs) for network learning. The nonlinear relationship between RSS and the position is then accurately constructed by incrementally inserting the DCs and recursively updating the weightings in the network until no further improvement is required. Our localization system is developed in a real-world wireless LAN WLAN environment, where the realistic RSS measurement is collected. We implement the traditional approaches on the same test bed, including weighted kappa-nearest neighbor (WKNN), maximum likelihood (ML), and multilayer perceptron (MLP), and compare the results. The experimental results indicate that the proposed algorithm is much higher in accuracy compared with other examined techniques. The improvement can be attributed to that only the useful information is efficiently extracted for positioning while the redundant information is regarded as noise and discarded. Finally, the analysis shows that our network intelligently accomplishes learning while the inserted DCs provide sufficient information.

  7. Blind RSSD-Based Indoor Localization with Confidence Calibration and Energy Control

    Directory of Open Access Journals (Sweden)

    Tengyue Zou

    2016-05-01

    Full Text Available Indoor localization based on wireless sensor networks (WSNs is an important field of research with numerous applications, such as elderly care, miner security, and smart buildings. In this paper, we present a localization method based on the received signal strength difference (RSSD to determine a target on a map with unknown transmission information. To increase the accuracy of localization, we propose a confidence value for each anchor node to indicate its credibility for participating in the estimation. An automatic calibration device is designed to help acquire the values. The acceleration sensor and unscented Kalman filter (UKF are also introduced to reduce the influence of measuring noise in the application. Energy control is another key point in WSN systems and may prolong the lifetime of the system. Thus, a quadtree structure is constructed to describe the region correlation between neighboring areas, and the unnecessary anchor nodes can be detected and set to sleep to save energy. The localization system is implemented on real-time Texas Instruments CC2430 and CC2431 embedded platforms, and the experimental results indicate that these mechanisms achieve a high accuracy and low energy cost.

  8. MEASUREMENT OF INDOOR RADON-THORON IN AIR AND EXHALATION FROM SOIL IN THE ENVIRONMENT OF WESTERN HARYANA, INDIA.

    Science.gov (United States)

    Mann, Nisha; Kumar, Amit; Kumar, Sushil; Chauhan, R P

    2016-10-01

    Measurement of indoor radon and thoron is important because the inhalation of radon-thoron and their daughters contributes more than 50 % of the total dose from natural sources. One of the important parameters to find out the contribution of soil and building materials towards indoor radon is radon exhalation rates, which can be used for estimation of indoor radon levels. The indoor radon and thoron levels from the air and radon exhalation rates from soil samples collected from two districts (Hisar and Fatehabad) of Western Haryana are measured using pin-hole-based radon-thoron dosimeter and LR-115 solid-state nuclear track detector by canister technique. The results show that the indoor radon and thoron levels from Hisar district varied from 11 to 112 and 11 to 80 Bq m -3 , while for Fatehabad district from 5 to 24 and 59 to 105 Bq m -3 , respectively, in summer season. In winter season, indoor radon and thoron levels from Hisar district varied from 15 to 43 and 32 to 102 Bq m -3 , while for Fatehabad district from 18 to 31 and 11 to 80 Bq m -3 , respectively. The indoor radon levels of 95 % locations lie well below the limit recommended by International Commission of Radiation Protection, 2011. The radon mass exhalation rate varied from 6 to 56 mBq kg -1 h -1 The radon mass exhalation rates from the soil samples were lower than the worldwide average, i.e. 56 mBq kg -1 h -1 There exists a poor correlation between indoor radon and exhalation rates. More investigations of measurement of radionuclide contents from rock and stone of study area can improve the understanding. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  9. Invariant Observer-Based State Estimation for Micro-Aerial Vehicles in GPS-Denied Indoor Environments Using an RGB-D Camera and MEMS Inertial Sensors

    Directory of Open Access Journals (Sweden)

    Dachuan Li

    2015-04-01

    Full Text Available This paper presents a non-linear state observer-based integrated navigation scheme for estimating the attitude, position and velocity of micro aerial vehicles (MAV operating in GPS-denied indoor environments, using the measurements from low-cost MEMS (micro electro-mechanical systems inertial sensors and an RGB-D camera. A robust RGB-D visual odometry (VO approach was developed to estimate the MAV’s relative motion by extracting and matching features captured by the RGB-D camera from the environment. The state observer of the RGB-D visual-aided inertial navigation was then designed based on the invariant observer theory for systems possessing symmetries. The motion estimates from the RGB-D VO were fused with inertial and magnetic measurements from the onboard MEMS sensors via the state observer, providing the MAV with accurate estimates of its full six degree-of-freedom states. Implementations on a quadrotor MAV and indoor flight test results demonstrate that the resulting state observer is effective in estimating the MAV’s states without relying on external navigation aids such as GPS. The properties of computational efficiency and simplicity in gain tuning make the proposed invariant observer-based navigation scheme appealing for actual MAV applications in indoor environments.

  10. Effect of Chloride on Tensile and Bending Capacities of Basalt FRP Mesh Reinforced Cementitious Thin Plates under Indoor and Marine Environments

    Directory of Open Access Journals (Sweden)

    Yan Xie

    2016-01-01

    Full Text Available This paper presented a durability experimental study for thin basalt fiber reinforced polymer (BFRP mesh reinforced cementitious plates under indoor and marine environment. The marine environment was simulated by wetting/drying cycles (wetting in salt water and drying in hot air. After 12 months of exposure, the effects of the chloride on the tensile and bending behaviors of the thin plate were investigated. In addition to the penetration of salt water, the chloride in the thin plate could be also from the sea sand since it is a component of the plate. Experimental results showed that the effect of the indoor exposure on the tensile capacity of the plate is not pronounced, while the marine exposure reduced the tensile capacity significantly. The bending capacity of the thin plates was remarkably reduced by both indoor and marine environmental exposure, in which the effect of the marine environment is more severe. The tensile capacity of the meshes extracted from the thin plates was tested, as well as the meshes immersed in salt solution for 30, 60, and 90 days. The test results confirmed that the chloride is the reason of the BFRP mesh deterioration. Moreover, as a comparison, the steel mesh reinforced thin plate was also tested and it has a similar durability performance.

  11. Monitoring Indoor Air Quality for Enhanced Occupational Health.

    Science.gov (United States)

    Pitarma, Rui; Marques, Gonçalo; Ferreira, Bárbara Roque

    2017-02-01

    Indoor environments are characterized by several pollutant sources. Because people spend more than 90% of their time in indoor environments, several studies have pointed out the impact of indoor air quality on the etiopathogenesis of a wide number of non-specific symptoms which characterizes the "Sick Building Syndrome", involving the skin, the upper and lower respiratory tract, the eyes and the nervous system, as well as many building related diseases. Thus, indoor air quality (IAQ) is recognized as an important factor to be controlled for the occupants' health and comfort. The majority of the monitoring systems presently available is very expensive and only allow to collect random samples. This work describes the system (iAQ), a low-cost indoor air quality monitoring wireless sensor network system, developed using Arduino, XBee modules and micro sensors, for storage and availability of monitoring data on a web portal in real time. Five micro sensors of environmental parameters (air temperature, humidity, carbon monoxide, carbon dioxide and luminosity) were used. Other sensors can be added for monitoring specific pollutants. The results reveal that the system can provide an effective indoor air quality assessment to prevent exposure risk. In fact, the indoor air quality may be extremely different compared to what is expected for a quality living environment. Systems like this would have benefit as public health interventions to reduce the burden of symptoms and diseases related to "sick buildings".

  12. INDOOR AIR POLLUTION

    OpenAIRE

    Ahmet Soysal; Yucel Demiral

    2007-01-01

    The existance of hazardious materials including biological, chemical, and physical agents such as carbon dioxide, carbon monoxide, sulphur dioxide, nitrogen oxides, radon, volotile organic compounds, microorganisms in houses and the other non-industrilized buildings have been defined as “indoor air pollution”. Indoor air pollutants could possible arised from inside or outside environment and categorized into six subgroups. Almost 80% Turkish population have living in the urban areas...

  13. Exposure levels due to WLAN devices in indoor environments corrected by a time-amplitude factor of distribution of the quasi-stochastic signals

    International Nuclear Information System (INIS)

    Miclaus, Simona; Bechet, Paul; Stratakis, Dimitrios

    2014-01-01

    With the development of radiofrequency technology, radiating quasi-stochastic signals like the wireless local area networks (WLAN), a proper procedure of exposure level assessment is needed. No standardised procedure exists at the moment. While channel power measurement proved to overestimate the field strength, weighting techniques were proposed. The paper compares the exposure levels determined by three different procedures, two of them correcting the field level by weighting. Twenty-three experimental cases of WLAN traffic load are analysed in an indoor environment in controlled conditions. The results show the differences obtained when the duty cycle (DC) method is applied comparatively with the application of weighting based on an amplitude-time correction. Significant exposure level reductions of 52.6-79.2 % from the field determined by frequency domain method and of 36.5-72.8 % from the field determined by the DC weighting method were obtained by time-amplitude method. Specificities of weighting factors probability density functions were investigated and regression analysis was applied for a detailed characterisation of this procedure. (authors)

  14. Aerosol transport simulations in indoor and outdoor environments using computational fluid dynamics (CFD)

    Science.gov (United States)

    Landazuri, Andrea C.

    This dissertation focuses on aerosol transport modeling in occupational environments and mining sites in Arizona using computational fluid dynamics (CFD). The impacts of human exposure in both environments are explored with the emphasis on turbulence, wind speed, wind direction and particle sizes. Final emissions simulations involved the digitalization process of available elevation contour plots of one of the mining sites to account for realistic topographical features. The digital elevation map (DEM) of one of the sites was imported to COMSOL MULTIPHYSICSRTM for subsequent turbulence and particle simulations. Simulation results that include realistic topography show considerable deviations of wind direction. Inter-element correlation results using metal and metalloid size resolved concentration data using a Micro-Orifice Uniform Deposit Impactor (MOUDI) under given wind speeds and directions provided guidance on groups of metals that coexist throughout mining activities. Groups between Fe-Mg, Cr-Fe, Al-Sc, Sc-Fe, and Mg-Al are strongly correlated for unrestricted wind directions and speeds, suggesting that the source may be of soil origin (e.g. ore and tailings); also, groups of elements where Cu is present, in the coarse fraction range, may come from mechanical action mining activities and saltation phenomenon. Besides, MOUDI data under low wind speeds (Computational Fluid Dynamics can be used as a source apportionment tool to identify areas that have an effect over specific sampling points and susceptible regions under certain meteorological conditions, and these conclusions can be supported with inter-element correlation matrices and lead isotope analysis, especially since there is limited access to the mining sites. Additional results concluded that grid adaption is a powerful tool that allows to refine specific regions that require lots of detail and therefore better resolve flow detail, provides higher number of locations with monotonic convergence than the

  15. Sampling artifacts in measurement of elemental and organic carbon: Low-volume sampling in indoor and outdoor environments

    Science.gov (United States)

    Olson, David A.; Norris, Gary A.

    Experiments were completed to determine the extent of artifacts from sampling elemental carbon (EC) and organic carbon (OC) under sample conditions consistent with personal sampling. Two different types of experiments were completed; the first examined possible artifacts from oils used in personal environmental monitor (PEM) impactor plates, and the second examined artifacts from microenvironmental sampling using different sampling media combinations (quartz, Teflon, XAD denuder, and electrostatic precipitator). The effectiveness of front and backup filters was evaluated for most sampling configurations. Mean total carbon concentrations from sampling configurations using impactor oils were not statistically different from the control case (using a sharp cut cyclone). Three microenvironments were tested (kitchen, library, and ambient); carbon concentrations were highest in the kitchen using a front quartz filter (mean OC of 16.4 μg m -3). The lowest front quartz filter concentrations were measured in the library using XAD denuders (mean OC of 3.6 μg m -3). Denuder removal efficiencies (average of 82% for total carbon) were lower compared with previous ambient studies and may indicate that indoor sources influenced denuder efficiency during sample collection. The highest carbon concentrations from backup quartz filters were measured using the Teflon-quartz combination.

  16. Indoor air quality

    International Nuclear Information System (INIS)

    Hollowell, C.D.

    1981-06-01

    Rising energy prices, among other factors, have generated an incentive to reduce ventilation rates and thereby reduce the cost of heating and cooling buildings. Reduced ventilation in buildings may significantly increase exposure to indoor air pollution and perhaps have adverse effects on occupant health and comfort. Preliminary findings suggest that reduced ventilation may adversely affect indoor air quality unless appropriate control strategies are undertaken. The strategies used to control indoor air pollution depend on the specific pollutant or class of pollutants encountered, and differ somewhat depending on whether the application is to an existing building or a new building under design and construction. Whenever possible, the first course of action is prevention or reduction of pollutant emissions at the source. In most buildings, control measures involve a combination of prevention, removal, and suppression. Common sources of indoor air pollution in buildings, the specific pollutants emitted by each source, the potential health effects, and possible control techniques are discussed

  17. Feedback of experience from the first passive houses - indoor environment, durability and user friendliness; Erfarenhetsaaterfoering fraan de foersta passivhusen - innemiljoe, bestaendighet och brukarvaenlighet

    Energy Technology Data Exchange (ETDEWEB)

    Sikander, Eva; Ruud, Svein; Fyhr, Kristina; Svensson, Owe

    2011-07-01

    Experience and evaluation of ten-year-old passive houses - indoor environment, durability and user convenience Although many passive houses and low-energy houses were evaluated while they were still newly built, there has not been much evaluation of them after several years' of occupation. This indicates a need to re-visit older passive houses in order to pick up any aspects that could be improved in the interests of operating aspects, good indoor environmental conditions, moisture safety or continued low energy use. The objective of this project has been to provide the building sector with feedback of experience from the first passive houses in Sweden, which were first occupied in 2001. User experiences have been collected through interviews, and indoor environmental conditions and the performance of technical systems have been monitored and measured. Energy use data for the houses has also been obtained. The work has been carried out on ten of the twenty terrace house units that were built outside Goeteborg. As the houses were thoroughly monitored while they were new, we can see if and how they have changed over their first ten years' occupation. The results shows that, in general, the occupants are very satisfied, although they have put forward proposals for certain improvements, linked to the fact that it is they themselves who operate and look after the houses. Similarly, measurement and monitoring of the indoor conditions and the technical systems shows that, in many respects, the houses have aged well, although there is also scope for improvement in order to ensure that the initially low energy consumption does not tend to increase, and to maintain the good indoor environmental conditions. Interviews, follow-up of energy use and measurements of indoor conditions and the performance of technical systems have included indoor thermal conditions, solar collector systems, performance of heat exchangers, air flows, acoustic conditions, airtightness of

  18. Indoor application of attractive toxic sugar bait (ATSB in combination with mosquito nets for control of pyrethroid-resistant mosquitoes.

    Directory of Open Access Journals (Sweden)

    Zachary P Stewart

    Full Text Available BACKGROUND: Attractive toxic sugar bait (ATSB sprayed onto vegetation has been successful in controlling Anopheles mosquitoes outdoors. Indoor application of ATSB has yet to be explored. The purpose of this study was to determine whether ATSB stations positioned indoors have the potential to kill host-seeking mosquitoes and constitute a new approach to control of mosquito-borne diseases. METHODS: Insecticides were mixed with dyed sugar solution and tested as toxic baits against Anopheles arabiensis, An. Gambiae s.s. and Culex quinquefasciatus in feeding bioassay tests to identify suitable attractant-insecticide combinations. The most promising ATSB candidates were then trialed in experimental huts in Moshi, Tanzania. ATSB stations were hung in huts next to untreated mosquito nets occupied by human volunteers. The proportions of mosquitoes killed in huts with ATSB treatments relative to huts with non-insecticide control treatments huts were recorded, noting evidence of dye in mosquito abdomens. RESULTS: In feeding bioassays, chlorfenapyr 0.5% v/v, boric acid 2% w/v, and tolfenpyrad 1% v/v, mixed in a guava juice-based bait, each killed more than 90% of pyrethroid-susceptible An. Gambiae s.s. and pyrethroid-resistant An. arabiensis and Cx. quinquefasciatus. In the hut trial, mortality rates of the three ATSB treatments ranged from 41-48% against An. arabiensis and 36-43% against Cx. quinquefasciatus and all were significantly greater than the control mortalities: 18% for An. arabiensis, 7% for Cx. quinquefasciatus (p<0.05. Mortality rates with ATSB were comparable to those with long lasting insecticidal nets previously tested against the same species in this area. CONCLUSIONS: Indoor ATSB shows promise as a supplement to mosquito nets for controlling mosquitoes. Indoor ATSB constitute a novel application method for insecticide classes that act as stomach poisons and have not hitherto been exploited for mosquito control. Combined with LLIN, indoor

  19. Indoor Fungal and Bacterial Contaminations on Household Environment in Riyadh, Saudi Arabia

    International Nuclear Information System (INIS)

    Alwakeel, Suaad S

    2008-01-01

    This study was conducted to determine the microbial and inhabitant of household environment in Riyadh, Saudi Arabia. Overall, a total of 180 samples were collected and analyzed for fungal growth, 160 house samples were obtained on BAP medium and PDA medium. The Eastern Riyadh region turned out with the highest fungal isolates with 15/61 (24.6%). Among the most common fungal isolates from bedroom carpets were Aspergillus niger (21.6%), Alternaria sp. (15.7%), Aspergillus flavus (15.7%) Candida sp. (11.8%), Cladosporium sp. (9.8%) and Rhizopus sp. (9.8%). Other fungal isolates from bedroom carpets included Penicillium sp (5.9%)., Cunninghamella sp.(3.9%), Rhodotorula sp.(3.9%) and Aspergillus terreus (1.9%) Overall relative densities from all specimens obtained from household carpets, bedroom walls and carpet stores showed Alternaria spp. as the most common fungal isolate (55.3%) followed by Aspergillus niger (29%), Aspergillus flavus (19.3%), Rhizopus spp. (9.7%) and Penicillium spp. (7.0%). Other fungal isolates such as Candida spp., Cladosporium spp., Cunninghamella spp., Rhodotorula spp. and Aspergillus terreus had less than 6% overall relative density. From 40 carpet specimens collected for microbial analysis, 20 (50%) showed bacterial growth. Bacillus spp. was the most common isolated organism (35%) followed by Staphylococcus epidermidis (10%), Epiococcus spp. (10%), Corynebacterium spp. (10%) and Bacillus polymyxa (10%). Other bacterial isolates included Bacillus subtilis, Pseudomonas aeruginosa, Bacteroides spp., Clostridium spp. and Staphylococcus aureus .The presence of these fungal and microbial pathogens poses risk for individuals. When possible, floor carpeting in homes should be minimized or avoided since this serves as habitats for opportunistic fungi and infectious agents that pose harm to one's health. (author)

  20. Cooperative Agreement Funding for Indoor Air Quality

    Science.gov (United States)

    The Indoor Environments Division has created partnership with public and private sector entities to help encourage the public to take action to minimize their risk and mitigate indoor air quality problems.

  1. Concentrations of polybrominated diphenyl ethers (PBDEs) in central air-conditioner filter dust and relevance of non-dietary exposure in occupational indoor environments in Greece.

    Science.gov (United States)

    Besis, Athanasios; Katsoyiannis, Athanasios; Botsaropoulou, Elisavet; Samara, Constantini

    2014-05-01

    Polybrominated Diphenyl Ethers (PBDEs) are ubiquitous in the indoor environment owing to their use in consumer products and various studies around the world have found higher concentrations indoors than outdoors. Central air conditioner (A/C) systems have been widely used in many workplaces, therefore, studying of PBDEs in central A/C filter dust is useful to better understand the occurrences and health implications of PBDEs in indoor environments. The present study examined the occurrence of PBDEs in central A/C filter dust collected from various workplaces (n = 20) in Thessaloniki, Greece. The sum concentrations of 21 target congeners (∑21PBDE) in A/C dust ranged between 84 and 4062 ng g(-1) with a median value of 1092 ng g(-1), while BDE-209 was found to be the most abundant BDE congener. The daily intake via dust ingestion of PBDEs estimated for the employees of the occupational settings ranged from 3 to 45 ng day(-1) (median 12 ng day(-1)). Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Concentrations of polybrominated diphenyl ethers (PBDEs) in central air-conditioner filter dust and relevance of non-dietary exposure in occupational indoor environments in Greece

    International Nuclear Information System (INIS)

    Besis, Athanasios; Katsoyiannis, Athanasios; Botsaropoulou, Elisavet; Samara, Constantini

    2014-01-01

    Polybrominated Diphenyl Ethers (PBDEs) are ubiquitous in the indoor environment owing to their use in consumer products and various studies around the world have found higher concentrations indoors than outdoors. Central air conditioner (A/C) systems have been widely used in many workplaces, therefore, studying of PBDEs in central A/C filter dust is useful to better understand the occurrences and health implications of PBDEs in indoor environments. The present study examined the occurrence of PBDEs in central A/C filter dust collected from various workplaces (n = 20) in Thessaloniki, Greece. The sum concentrations of 21 target congeners (∑ 21 PBDE) in A/C dust ranged between 84 and 4062 ng g −1 with a median value of 1092 ng g −1 , while BDE-209 was found to be the most abundant BDE congener. The daily intake via dust ingestion of PBDEs estimated for the employees of the occupational settings ranged from 3 to 45 ng day −1 (median 12 ng day −1 ). - Highlights: • PBDEs were investigated in dust of A/C filters in occupational settings in Thessaloniki, Greece. • BDE-209 was found to be the most abundant BDE congener. • High levels of PBDEs were found in a newspaper building, internet cafes and electronic shops. • PBDEs were attributable to the extensive presence and/or usage of electronic devices. • Exposure of employees to PBDEs via indoor dust ingestion was estimated at 12 ng day −1 . - PBDEs were for the first time measured in dust from central A/C filters in workplaces of Greece and their concentrations were used to estimate the non-dietary human exposure

  3. Indoor air quality environmental information handbook: Combustion sources

    Energy Technology Data Exchange (ETDEWEB)

    1990-06-01

    This environmental information handbook was prepared to assist both the non-technical reader (i.e., homeowner) and technical persons (such as researchers, policy analysts, and builders/designers) in understanding the current state of knowledge regarding combustion sources of indoor air pollution. Quantitative and descriptive data addressing the emissions, indoor concentrations, factors influencing indoor concentrations, and health effects of combustion-generated pollutants are provided. In addition, a review of the models, controls, and standards applicable to indoor air pollution from combustion sources is presented. The emphasis is on the residential environment. The data presented here have been compiled from government and privately-funded research results, conference proceedings, technical journals, and recent publications. It is intended to provide the technical reader with a comprehensive overview and reference source on the major indoor air quality aspects relating to indoor combustion activities, including tobacco smoking. In addition, techniques for determining potential concentrations of pollutants in residential settings are presented. This is an update of a 1985 study documenting the state of knowledge of combustion-generated pollutants in the indoor environment. 191 refs., 51 figs., 71 tabs.

  4. Performance Analysis of IEEE 802.15.4 Compliant Wireless Devices for Heterogeneous Indoor Home Automation Environments

    Directory of Open Access Journals (Sweden)

    Juan Antonio Nazabal

    2012-01-01

    Full Text Available The influence of topology as well as morphology of complex indoor scenarios in the deployment of wireless sensor networks and wireless systems applied to home and building automation systems is analyzed. The existence of loss mechanisms such as material absorption (walls, furniture, etc. and strong multipath components as well as the increase in the number of wireless sensors within indoor scenarios increases the relevance in the configuration of the heterogeneous wireless systems. Simulation results by means of empirical-based models are compared with an in-house 3D ray launching code as well as measurement results from wireless sensor networks illustrate the strong influence of the indoor scenario in the overall performance. The use of adequate radioplanning strategies lead to optimal wireless network deployments in terms of capacity, quality of service, and reduced power consumption.

  5. CONTROL ENVIRONMENT IN KOSOVO PUBLIC INSTITUTIONS

    Directory of Open Access Journals (Sweden)

    Shaqir M. REXHEPI

    2015-06-01

    Full Text Available The study on how is Internal Control System developed in public institutions is of a special importance for modalities, forms and the manner of the application of relevant strategies for the functioning of internal control environment in public institutions. In this paper, there is treated the existing situation of internal control system environment of public finances and its implementation in public sector. For internal control system environment in public finances to function effectively, there should exist a coherent control environment which includes responsibilities for financial management from managers of Publicly Owned Enterprises and with complete functioning of internal audit, which exists in the function of development to add value. In Kosovo public institutions, this framework is offered by legislation and by institutional mechanism for the implementation of legislation according to these parameters.

  6. Relationship of Indoor, Outdoor and Personal Air (RIOPA) study: study design, methods and quality assurance/control results.

    Science.gov (United States)

    Weisel, Clifford P; Zhang, Junfeng; Turpin, Barbara J; Morandi, Maria T; Colome, Steven; Stock, Thomas H; Spektor, Dalia M; Korn, Leo; Winer, Arthur; Alimokhtari, Shahnaz; Kwon, Jaymin; Mohan, Krishnan; Harrington, Robert; Giovanetti, Robert; Cui, William; Afshar, Masoud; Maberti, Silvia; Shendell, Derek

    2005-03-01

    The Relationship of Indoor, Outdoor and Personal Air (RIOPA) Study was undertaken to evaluate the contribution of outdoor sources of air toxics, as defined in the 1990 Clean Air Act Amendments, to indoor concentrations and personal exposures. The concentrations of 18 volatile organic compounds (VOCs), 17 carbonyl compounds, and fine particulate matter mass (PM(2.5)) were measured using 48-h outdoor, indoor and personal air samples collected simultaneously. PM2.5 mass, as well as several component species (elemental carbon, organic carbon, polyaromatic hydrocarbons and elemental analysis) were also measured; only PM(2.5) mass is reported here. Questionnaires were administered to characterize homes, neighborhoods and personal activities that might affect exposures. The air exchange rate was also measured in each home. Homes in close proximity (<0.5 km) to sources of air toxics were preferentially (2:1) selected for sampling. Approximately 100 non-smoking households in each of Elizabeth, NJ, Houston, TX, and Los Angeles, CA were sampled (100, 105, and 105 respectively) with second visits performed at 84, 93, and 81 homes in each city, respectively. VOC samples were collected at all homes, carbonyls at 90% and PM(2.5) at 60% of the homes. Personal samples were collected from nonsmoking adults and a portion of children living in the target homes. This manuscript provides the RIOPA study design and quality control and assurance data. The results from the RIOPA study can potentially provide information on the influence of ambient sources on indoor air concentrations and exposure for many air toxics and will furnish an opportunity to evaluate exposure models for these compounds.

  7. Regulatory control of natural ionizing sources in Lithuania: Experience based on indoor radon monitoring

    International Nuclear Information System (INIS)

    Mastauskas, A.; Morkunas, G.

    1997-01-01

    The situation in legislation of protection against risks from natural sources of ionizing radiation in Lithuania is described. The requirements of new standards came into conflict with the real situation which has not been evaluated before implementation of these standards. On the basis of recommendations of ICRP Publication 60 and results of indoor radon survey new action levels are being established. (author)

  8. Technology Of Controlled-Environment Agriculture

    Science.gov (United States)

    Bubenheim, David L.; Bates, Maynard E.

    1995-01-01

    Report discusses controlled-environment agriculture (CEA) for commercial production of organisms, whether plants or animals. Practiced in greenhouses to produce food on nonarable lands. Describes conceptual regenerative system that incorporates biological, physical, and chemical processes to support humans in extraterrestrial environments.

  9. Indoor tanning in businesses and homes and risk of melanoma and nonmelanoma skin cancer in 2 US case-control studies.

    Science.gov (United States)

    Ferrucci, Leah M; Vogel, Rachel Isaksson; Cartmel, Brenda; Lazovich, DeAnn; Mayne, Susan T

    2014-11-01

    Indoor tanning increases skin cancer risk. Beyond early research describing melanoma and sun lamps, few recent reports describe where individuals indoor tan and whether skin cancer risk varies by location (business, home-based). We sought to assess where individuals tanned indoors and skin cancer risk by tanning device location. Multivariate logistic regression was conducted in 2 US case-control studies of melanoma (1161 cases, 1083 controls, ages 25-59 years) and early-onset basal cell carcinoma (375 cases, 382 controls, agetanned exclusively in businesses. Persons who used indoor tanning exclusively in businesses were at increased risk of melanoma (odds ratio 1.82, 95% confidence interval 1.47-2.26) and basal cell carcinoma (odds ratio 1.69, 95% confidence interval 1.15-2.48) compared with non-users. Melanoma risk was also increased in the small number who reported tanning indoors only at home relative to non-users (odds ratio 4.14, 95% confidence interval 1.75-9.78); 67.6% used sun lamps. Self-reported tanning and potential recall bias are limitations. Business-only tanning, despite claims of "safe" tanning, was positively associated with a significant risk of melanoma and basal cell carcinoma. Home tanning was uncommon and mostly from sun lamps, which were rarely used by younger participants. Regardless of location, indoor tanning was associated with increased risk of skin cancer. Copyright © 2014 American Academy of Dermatology, Inc. Published by Elsevier Inc. All rights reserved.

  10. The Performance Analysis of the Map-Aided Fuzzy Decision Tree Based on the Pedestrian Dead Reckoning Algorithm in an Indoor Environment

    Directory of Open Access Journals (Sweden)

    Kai-Wei Chiang

    2015-12-01

    Full Text Available Hardware sensors embedded in a smartphone allow the device to become an excellent mobile navigator. A smartphone is ideal for this task because its great international popularity has led to increased phone power and since most of the necessary infrastructure is already in place. However, using a smartphone for indoor pedestrian navigation can be problematic due to the low accuracy of sensors, imprecise predictability of pedestrian motion, and inaccessibility of the Global Navigation Satellite System (GNSS in some indoor environments. Pedestrian Dead Reckoning (PDR is one of the most common technologies used for pedestrian navigation, but in its present form, various errors tend to accumulate. This study introduces a fuzzy decision tree (FDT aided by map information to improve the accuracy and stability of PDR with less dependency on infrastructure. First, the map is quickly surveyed by the Indoor Mobile Mapping System (IMMS. Next, Bluetooth beacons are implemented to enable the initializing of any position. Finally, map-aided FDT can estimate navigation solutions in real time. The experiments were conducted in different fields using a variety of smartphones and users in order to verify stability. The contrast PDR system demonstrates low stability for each case without pre-calibration and post-processing, but the proposed low-complexity FDT algorithm shows good stability and accuracy under the same conditions.

  11. The Comfort Houses : measurements and analysis of the indoor environment and energy consumption in 8 passive houses 2008-2011

    Energy Technology Data Exchange (ETDEWEB)

    Steen Larsen, T.; Lund Jensen, R.; Daniels, O.

    2012-01-15

    The report is prepared in relation to the project ''demonstration of energy consumption and indoor climate in 10 Danish passive houses'' which was carried out from 2008 to 2012 in the Comfort Houses. The report presents the achieved results based on measurements of indoor climate and energy consumption, and it also suggests viable solutions for the future low-energy buildings. The Comfort House project was started in 2007 as a development project at the company Saint Gobain Isover A/S, who wanted to disseminate knowledge about low-energy buildings and the principles behind them. The present report mainly focuses on the results from the Comfort Houses, but it also includes references to other Danish experimental buildings and development projects. Furthermore, the analyses are supplemented with experiences from Swedish low-energy buildings found through literature reviews. The indoor climate analyses deal with the different physical parameters that impact the residents. The evaluation includes both thermal, atmospheric, daylight and acoustic climate. The energy consumption is evaluated together with some of the key parameters from the houses that are related to the energy consumption. Finally, the residents' behaviour impacting both energy consumption and indoor climate are analysed. (LN)

  12. Exposure Reduction to Human Bio-effluents Using Seat-integrated Localized Ventilation in Quiescent Indoor Environment

    DEFF Research Database (Denmark)

    Bivolarova, Mariya Petrova; Rezgals, Lauris; Melikov, Arsen Krikor

    2016-01-01

    Local airflows generated from people such as the natural convection flow may determine the distribution of pollutants indoors. New seat-integrated ventilated method was developed to improve the inhaled air quality of occupants while sitting The method named “Ventilated Cushion” was designed to suck...

  13. 3D Indoor Building Environment Reconstruction using Polynomial Kernel, Least Square Adjustment, Interval Analysis and Homotopy Continuation

    DEFF Research Database (Denmark)

    Jamali, Ali; Rahman, Alias Abdul; Antón Castro, Francesc/François

    2016-01-01

    Nowadays, municipalities intend to have 3D city models for facility management, disaster management and architectural planning. Indoor models can be reconstructed from construction plans but sometimes, they are not available or very often, they differ from ‘as-built’ plans. In this case...

  14. Indoor environment and allergy except housedust mite; Jukankyo to allergy ni kansuru dani igai no chosa kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Nakao, F.; Nishima, S.

    1998-05-31

    Pathopoiesis factors of allergic diseases include immune antibody productivity sthenia reacting with antigens such as mite or the like in allergy reaction which is regarded as based on genetic fact (atopic diathesis), and environmental factors as external factors. The environmental factors are further classified into specific factors (antigens) and nonspecific factors. The former factors include the indoor factors such as mite, mould, animals bred indoor, etc., and outdoor factors such as pollen and so on. The latter factors include indoor factors such as passive smoking, carbon monoxide, nitrogen oxides, formaldehyde, etc., and outdoor factors such as sulfur oxides, nitrogen oxides, airborne particles and so on. In this paper, the environmental factors in relation to allergic diseases expect mite are introduced. Besides mould, cockroach/insect, fur dust and dandruff of animals, adjustment of room temperature/humidity, smoking, indoor and outdoor air pollution are mentioned as the environmental factors expect mite, and the cause-effect relations thereof are explained. 24 refs., 3 figs., 7 tabs.

  15. Indoor Tanning

    Science.gov (United States)

    ... proof that indoor tanning is safer than tanning outdoors. Indoor tanning systems give concentrated UV exposure regardless ... For example, it’s essential for promoting good bone health. While UV ... a tan to get that benefit. According to the Surgeon General, fair and light- ...

  16. Human response to individually controlled micro environment generated with localized chilled beam

    DEFF Research Database (Denmark)

    Uth, Simon C.; Nygaard, Linette; Bolashikov, Zhecho Dimitrov

    2014-01-01

    Indoor environment in a single-office room created by a localised chilled beam with individual control of the primary air flow was studied. Response of 24 human subjects when exposed to the environment generated by the chilled beam was collected via questionnaires under a 2-hour exposure including...... and local thermal sensation reported by the subjects with the two systems. Both systems were equally acceptable. At 26°C the individual control of the localised chilled beam lead to higher acceptability of the work environment. At 28°C the acceptability decreased with the two systems. It was not acceptable...... different work tasks at three locations in the room. Response of the subjects to the environment generated with a chilled ceiling combined with mixing air distribution was used for comparison. The air temperature in the room was kept at 26 or 28 °C. Results show no significant difference in the overall...

  17. Employee quality, monitoring environment and internal control

    OpenAIRE

    Chunli Liu; Bin Lin; Wei Shu

    2017-01-01

    We investigate the effect of internal control employees (ICEs) on internal control quality. Using special survey data from Chinese listed firms, we find that ICE quality has a significant positive influence on internal control quality. We examine the effect of monitoring on this result and find that the effect is more pronounced for firms with strict monitoring environments, especially when the firms implement the Chinese internal control regulation system (CSOX), have higher institutional ow...

  18. Control of Indoor Airflows for Reduction of Human Exposure to Aerosol Contaminants

    DEFF Research Database (Denmark)

    Bivolarova, Mariya Petrova

    . An increase of the air change rate did not affect the comparable normalized concentration distribution of the tracer gas and the larger particles, namely 0.7μm and 3.5 μm. However, the ventilation rate was important for comparing the behaviour of the ultrafine particles (0.07 μm) and the tracer gas......, there is still a need for improved understanding of the air movement in the vicinity of the occupants. Tracer gas measurements are often used to study exposure to both indoor generated gases and airborne particles (aerosols). The tracer gas, however, cannot be used as a common substitute for aerosols of all...... sizes due to the different physical forces acting on them. Determining to what extent tracer gas can be used as substitute for aerosols when assessing occupants’ exposure to indoor aerosols is needed and can be used for appropriate ventilation systems design. A properly developed ventilation method...

  19. Factors controlling indoor radon levels. Annual report, June 1983-May 1984

    International Nuclear Information System (INIS)

    Harley, N.H.

    1984-01-01

    The factors which contribute to indoor radon levels were investigated. Soil moisture content appears to be such a factor and influences indoor radon levels in a subtle way. The single family dwelling studied here is a typical suburban home, with a full basement, two living levels and a full attic. Seasonal data for 1981 to 1983 are shown by hour (about 90 hours in each average) for the basement, first floor and outdoors. A twenty-five story, 225 apartment, high rise building has been under study for about the same time interval. The apartment has five rooms, and is on the 24th floor. Continuous monitors are located in a work room and outdoors on a terrace. Data are available from the summer of 1981. 2 references, 12 figures, 9 tables

  20. TVOC and health in non-industrial indoor environments. Reports from a Nordic scientific consensus meeting at Långholmen in Stockholm, 1996

    DEFF Research Database (Denmark)

    K., Andersson; Bakke, J.V.; Bjørseth, O.

    1997-01-01

    and interpretations of TVOC. This means that simple addition of the quantities of individual VOCs may not be relevant from a health point of view. Twelve researchers from the Nordic countries have reviewed the literature on VOC/TVOC and health. A search of the literature resulted in the identification of about 1100...... in indoor environments in non-industrial buildings. However, the scientific literature is inconclusive with respect to TVOC as a risk index for health and comfort effects in buildings. Consequently, there is at present an inadequate scientific basis on which to establish limit values/guidelines for TVOC...

  1. Interior shadings for office indoor visual comfort in humid climate region

    Science.gov (United States)

    Dinapradipta, Asri; Sudarma, Erwin; Defiana, Ima; Erwindi, Collinthia

    2018-03-01

    As part of the fenestration system, the interior shadings have also a role to control the indoor environment to maintain indoor visual comfort. As the occupants have personal access to control these, their control behavior then, might enhance or even worsen indoor comfort performance. The controlling behavior might not only influence indoor comfort performance but can also indicate the success or failure of interior shading as a control device element. This paper is intended to report control behavior patterns, as represented by the variety of the slats’ openings of two types of interior shading i.e. Venetian and Vertical blinds and to analyze these on the concurrent impacts to indoor office building’s indoor illuminance and luminance distribution. The purpose of this research is to figure out the shading control patterns as well as to examine the effectiveness of these two types of interior shadings to control indoor visual environment. This study is a quantitative research using experimentation on the slats’ opening of two types of shadings at two identical office rooms. The research results suggested that both types of blinds seem unsuitable for gaining proper illumination values at work planes in humid tropics area. However, these shadings demonstrate good performance for luminance distribution except for that of the closed Venetian blinds.

  2. Improving indoor air quality for poor families : a controlled experiment in Bangladesh

    OpenAIRE

    Dasgupta, Susmita; Huq, Mainul; Khaliquzzaman, M.; Wheeler, David

    2007-01-01

    The World Health Organization's 2004 Global and Regional Burden of Disease Report estimates that acute respiratory infections from indoor air pollution (pollution from burning wood, animal dung, and other bio-fuels) kill a million children annually in developing countries, inflicting a particularly heavy toll on poor families in South Asia and Africa. This paper reports on an experiment that studied the use of different fuels in conjunction with different combinations of construction material...

  3. Office of radiation and indoor air: Program description

    International Nuclear Information System (INIS)

    1993-06-01

    The goal of the Environmental Protection Agency's (EPA) Office of Radiation and Indoor Air is to protect the public and the environment from exposures to radiation and indoor air pollutants. The Office develops protection criteria, standards, and policies and works with other programs within EPA and other agencies to control radiation and indoor air pollution exposures; provides technical assistance to states through EPA's regional offices and other agencies having radiation and indoor air protection programs; directs an environmental radiation monitoring program; responds to radiological emergencies; and evaluates and assesses the overall risk and impact of radiation and indoor air pollution. The Office is EPA's lead office for intra- and interagency activities coordinated through the Committee for Indoor Air Quality. It coordinates with and assists the Office of Enforcement in enforcement activities where EPA has jurisdiction. The Office disseminates information and works with state and local governments, industry and professional groups, and citizens to promote actions to reduce exposures to harmful levels of radiation and indoor air pollutants

  4. Robot motion control in mobile environment

    Institute of Scientific and Technical Information of China (English)

    Iliya V Miroshnik; HUANG Xian-lin(黄显林); HE Jie(贺杰)

    2003-01-01

    With the problem of robot motion control in dynamic environment represented by mobile obstacles,working pieces and external mechanisms considered, a relevant control actions design procedure has been pro-posed to provide coordination of robot motions with respect to the moving external objects so that an extension ofrobot spatial motion techniques and active robotic strategies based on approaches of nonlinear control theory canbe achieved.

  5. Internal control in an EDI environment.

    OpenAIRE

    Bae, Dal Hyeoung

    1991-01-01

    Approved for public release; distribution in unlimited. Electronic Data Interchange(EDI) is the electronic transmission of standard business documents in machine-readable format between parent companies and respective trading partners. As the use of EDI has grown, there have been the associated risks due to an uncontrolled environment. Accordingly, the necessity for effective internal controls in an EDI environment is on the rise. This thesis evaluates and analyzes the feasi...

  6. Indoor tanning in businesses and homes and risk of melanoma and non-melanoma skin cancer in two US case-control studies

    Science.gov (United States)

    Ferrucci, Leah M.; Vogel, Rachel Isaksson; Cartmel, Brenda; Lazovich, DeAnn; Mayne, Susan T.

    2014-01-01

    Background Indoor tanning increases skin cancer risk. Beyond early research describing melanoma and sun lamps, few recent reports describe where individuals indoor tan and whether skin cancer risk varies by location (business, home-based). Objective Assess where individuals tanned indoors and skin cancer risk by tanning device location. Methods Multivariate logistic regression in two US case-control studies of melanoma (1,161 cases, 1,083 controls, ages 25–59) and early-onset basal cell carcinoma (BCC) (375 cases, 382 controls, under age 40) conducted between 2004 and 2010. Results Most indoor tanners (86.4–95.1%), especially younger individuals, tanned exclusively in businesses. Persons who used indoor tanning exclusively in businesses were at increased risk of melanoma (OR=1.82, 95% CI=1.47–2.26) and BCC (OR=1.69, 95% CI=1.15–2.48) compared to non-users. Melanoma risk was also increased in the small number who reported tanning indoors only at home relative to non-users (OR=4.14, 95% CI=1.75–9.78); 67.6% used sun lamps. Limitations Self-reported tanning, potential recall bias. Conclusion Business only tanning, despite claims of “safe" tanning, was positively associated with a significant risk of melanoma and BCC. Home tanning was uncommon and mostly from sun lamps which were rarely used by younger participants. Regardless of location, indoor tanning was associated with increased risk of skin cancer. PMID:25062934

  7. Employee quality, monitoring environment and internal control

    Directory of Open Access Journals (Sweden)

    Chunli Liu

    2017-03-01

    Full Text Available We investigate the effect of internal control employees (ICEs on internal control quality. Using special survey data from Chinese listed firms, we find that ICE quality has a significant positive influence on internal control quality. We examine the effect of monitoring on this result and find that the effect is more pronounced for firms with strict monitoring environments, especially when the firms implement the Chinese internal control regulation system (CSOX, have higher institutional ownership or attach greater importance to internal control. Our findings suggest that ICEs play an important role in the design and implementation of internal control systems. Our study should be of interest to both top managers who wish to improve corporate internal control quality and regulators who wish to understand the mechanisms of internal control monitoring.

  8. Comfort and performance impact of personal control over thermal environment in summer

    DEFF Research Database (Denmark)

    Boerstra, Atze C.; te Kulve, Marije; Toftum, Jørn

    2015-01-01

    Field studies suggest that the availability of adjustable thermostats, operable windows and other controls has a positive impact on comfort, the incidence of building related symptoms and productivity. This laboratory study was designed to further investigate how having or not having control over...... the thermal environment affects human responses to the indoor environment.The study was conducted in summer in a field laboratory that was kept at 28°C. A total of 23 subjects were exposed twice for about 2.5h. During the first session (A) subjects were able to fine-tune their local thermal environment at any...... recorded during the first session. Thus, each subject was exposed to two customized conditions with identical exposure, only different from a psychological point of view.During the two sessions identical questionnaires and performance tests were used to evaluate subjects' comfort, SBS symptom incidence...

  9. Navigation and Self-Semantic Location of Drones in Indoor Environments by Combining the Visual Bug Algorithm and Entropy-Based Vision.

    Science.gov (United States)

    Maravall, Darío; de Lope, Javier; Fuentes, Juan P

    2017-01-01

    We introduce a hybrid algorithm for the self-semantic location and autonomous navigation of robots using entropy-based vision and visual topological maps. In visual topological maps the visual landmarks are considered as leave points for guiding the robot to reach a target point (robot homing) in indoor environments. These visual landmarks are defined from images of relevant objects or characteristic scenes in the environment. The entropy of an image is directly related to the presence of a unique object or the presence of several different objects inside it: the lower the entropy the higher the probability of containing a single object inside it and, conversely, the higher the entropy the higher the probability of containing several objects inside it. Consequently, we propose the use of the entropy of images captured by the robot not only for the landmark searching and detection but also for obstacle avoidance. If the detected object corresponds to a landmark, the robot uses the suggestions stored in the visual topological map to reach the next landmark or to finish the mission. Otherwise, the robot considers the object as an obstacle and starts a collision avoidance maneuver. In order to validate the proposal we have defined an experimental framework in which the visual bug algorithm is used by an Unmanned Aerial Vehicle (UAV) in typical indoor navigation tasks.

  10. Navigation and Self-Semantic Location of Drones in Indoor Environments by Combining the Visual Bug Algorithm and Entropy-Based Vision

    Directory of Open Access Journals (Sweden)

    Darío Maravall

    2017-08-01

    Full Text Available We introduce a hybrid algorithm for the self-semantic location and autonomous navigation of robots using entropy-based vision and visual topological maps. In visual topological maps the visual landmarks are considered as leave points for guiding the robot to reach a target point (robot homing in indoor environments. These visual landmarks are defined from images of relevant objects or characteristic scenes in the environment. The entropy of an image is directly related to the presence of a unique object or the presence of several different objects inside it: the lower the entropy the higher the probability of containing a single object inside it and, conversely, the higher the entropy the higher the probability of containing several objects inside it. Consequently, we propose the use of the entropy of images captured by the robot not only for the landmark searching and detection but also for obstacle avoidance. If the detected object corresponds to a landmark, the robot uses the suggestions stored in the visual topological map to reach the next landmark or to finish the mission. Otherwise, the robot considers the object as an obstacle and starts a collision avoidance maneuver. In order to validate the proposal we have defined an experimental framework in which the visual bug algorithm is used by an Unmanned Aerial Vehicle (UAV in typical indoor navigation tasks.

  11. Indoor Photography

    OpenAIRE

    Sagers, Stephen; Patterson, Ron

    2011-01-01

    Photography is the science of recording light in an artistic way to create a pleasing image. Indoor photography requires a photographer to become familiar with some of the built in functions of a camera.

  12. Visual operations control in administrative environments

    Energy Technology Data Exchange (ETDEWEB)

    Carson, M.L.; Levine, L.O.

    1995-03-01

    When asked what comes to mind when they think of ``controlling work`` in the office, people may respond with ``overbearing boss,`` ``no autonomy,`` or ``Theory X management.`` The idea of controlling work in white collar or administrative environments can have a negative connotation. However, office life is often chaotic and miserable precisely because the work processes are out of control, and managers must spend their time looking over people`s shoulders and fighting fires. While management styles and structures vary, the need for control of work processes does not. Workers in many environments are being reorganized into self-managed work teams. These teams are expected to manage their own work through increased autonomy and empowerment. However, even empowered work teams must manage their work processes because of process variation. The amount of incoming jobs vary with both expected (seasonal) and unexpected demand. The mixture of job types vary over time, changing the need for certain skills or knowledge. And illness and turnover affect the availability of workers with needed skills and knowledge. Clearly, there is still a need to control work, whether the authority for controlling work is vested in one person or many. Visual control concepts provide simple, inexpensive, and flexible mechanisms for managing processes in work teams and continuous improvement administrative environments.

  13. Evaluation of building envelopes from the viewpoint of capability of controlling thermal environment; Onnetsu kankyo chosei noryoku ni yoru kenchiku gaihi no hyoka no kokoromi

    Energy Technology Data Exchange (ETDEWEB)

    Umeda, K; Ono, S [Taisei Corp., Tokyo (Japan); Shukuya, M [Musashi Institute of Technology, Tokyo (Japan)

    1996-10-27

    The ability that architectural space improves the thermal environment in comparison with outdoor environment is called the `capability of controlling thermal environment.` As the value becomes higher, the indoor thermal environment is more improved. In this paper, the controlling capability of six building envelopes with different window systems was compared. The heat transfer in the wall and window system is approximated using a lumped mass model of heat capacity to obtain a heat balance equation and combined with the heat balance equation in indoor air for backward difference. The wall surface temperature and indoor air temperature in a calculation model are then calculated. A radiation absorption coefficient is used for mutual radiation on each wall. In the model, the adjoining room or first- and second-floor rooms were made the same in conditions as the model on the assumption that the one-side lighted office in an RC reference floor is in the non-illumination and non-airconditioning state. In summer, the controlling capability remarkably varies depending on the window system. For the window facing the south, the annual capability is more advanced than in other directions and the indoor thermal environment is improved on the average. 7 refs., 12 figs., 1 tab.

  14. Alternative treatments for indoor residual spraying for malaria control in a village with pyrethroid- and DDT-resistant vectors in The Gambia

    NARCIS (Netherlands)

    Tangena, J.A.A.; Adiamoh, M.; Alessandro, D' U.; Jarju, L.; Jawara, M.; Jeffries, D.; Malik, N.; Nwakanma, D.; Kaur, H.; Takken, W.; Lindsay, S.W.; Pinder, M.

    2013-01-01

    Background: Malaria vector control is threatened by resistance to pyrethroids, the only class of insecticides used for treating bed nets. The second major vector control method is indoor residual spraying with pyrethroids or the organochloride DDT. However, resistance to pyrethroids frequently

  15. INDOOR AIR POLLUTION

    Directory of Open Access Journals (Sweden)

    Ahmet Soysal

    2007-06-01

    Full Text Available The existance of hazardious materials including biological, chemical, and physical agents such as carbon dioxide, carbon monoxide, sulphur dioxide, nitrogen oxides, radon, volotile organic compounds, microorganisms in houses and the other non-industrilized buildings have been defined as “indoor air pollution”. Indoor air pollutants could possible arised from inside or outside environment and categorized into six subgroups. Almost 80% Turkish population have living in the urban areas and people in the cities have spending approximetely 90% of their time in the closed enviroments, health problems could increased due to indoor air pollution. Moreover, currently there is no specific regulation on this area. [TAF Prev Med Bull 2007; 6(3.000: 221-226

  16. INDOOR AIR POLLUTION

    Directory of Open Access Journals (Sweden)

    Ahmet Soysal

    2007-06-01

    Full Text Available The existance of hazardious materials including biological, chemical, and physical agents such as carbon dioxide, carbon monoxide, sulphur dioxide, nitrogen oxides, radon, volotile organic compounds, microorganisms in houses and the other non-industrilized buildings have been defined as “indoor air pollution”. Indoor air pollutants could possible arised from inside or outside environment and categorized into six subgroups. Almost 80% Turkish population have living in the urban areas and people in the cities have spending approximetely 90% of their time in the closed enviroments, health problems could increased due to indoor air pollution. Moreover, currently there is no specific regulation on this area. [TAF Prev Med Bull. 2007; 6(3: 221-226

  17. Energy Saving Alignment Strategy: Achieving energy efficiency in urban buildings by matching occupant temperature preferences with a building’s indoor thermal environment

    International Nuclear Information System (INIS)

    Xu, Xiaoqi; Culligan, Patricia J.; Taylor, John E.

    2014-01-01

    Highlights: • A novel strategy for energy savings in multi-family buildings is presented. • A household’s thermal preferences are matched with a unit’s thermal environment. • Potential energy savings are examined using public housing as a test case. • 2.1–42.0% primary energy savings are shown, depending on climate location. - Abstract: Existing strategies for residential energy savings through physical renovation or motivating occupant energy conservation behavior can be costly and/or have transitory effects. Focusing on multi-family dwellings, an important subset of the urban residential sector, we propose an Energy Saving Alignment Strategy (ESAS) that has advantageous cost-effectiveness and a long-lasting influence. By aligning the distribution of residents’ thermostat preferences with the indoor temperature, ESAS aims to maximize thermal comfort and, accordingly, energy savings in multi-family buildings where indoor temperatures vary between apartments as a function of apartment orientation and floor level. Using a case study of a 1084-apartment public housing complex in New York, we classify both occupants’ thermostat preferences and apartments’ operative temperatures into five groups, and optimize energy efficiency by assigning each group of occupants to the group of apartments that best aligns with their thermostat preference. We test ESAS in eight cities representing all four U.S. census regions and six climate zones. Simulation results reveal 2.1–42.0% in energy savings compared to random apartment assignments depending on geographic location, with the highest energy reductions occurring in cities with mild climates, where the range of occupant thermostat preferences coincides with the natural indoor temperature range. We conclude by providing suggested guidelines on how ESAS might work in practice, and recommendations for extending ESAS research

  18. Reducing indoor residential exposures to outdoor pollutants

    Energy Technology Data Exchange (ETDEWEB)

    Sherman, Max H.; Matson, Nance E.

    2003-07-01

    The basic strategy for providing indoor air quality in residences is to dilute indoor sources with outdoor air. This strategy assumes that the outdoor air does not have pollutants at harmful levels or that the outdoor air is, at least, less polluted than the indoor air. When this is not the case, different strategies need to be employed to ensure adequate air quality in the indoor environment. These strategies include ventilation systems, filtration and other measures. These strategies can be used for several types of outdoor pollution, including smog, particulates and toxic air pollutants. This report reviews the impacts that typical outdoor air pollutants can have on the indoor environment and provides design and operational guidance for mitigating them. Poor quality air cannot be used for diluting indoor contaminants, but more generally it can become an indoor contaminant itself. This paper discusses strategies that use the building as protection against potentially hazardous outdoor pollutants, including widespread pollutants, accidental events, and potential attacks.

  19. Employing volcanic tuff minerals in interior architecture design to reduce microbial contaminants and airborne fungal carcinogens of indoor environments.

    Science.gov (United States)

    Gedikoglu, Yaman; Gedikoglu, Gunduz; Berkin, Genco; Ceyhan, Taskin; Altinoz, Meric A

    2012-09-01

    Indoor volatile organic compounds (VOCs) have posed significant risks to human health since people have both shifted to a life spent, for the most part, indoors. Further, changes in materials used in the construction of buildings, furnishings, and tools either leak or encourage the production of VOCs. Whether these enclosed areas are residences, hospitals or workplaces (specifically composting facilities or closed farm buildings for raising livestock), VOCs can rise to levels that threaten people's health. VOCs can either originate from phenolic and benzene-like compounds in building materials and office furniture or from molds (fungi) growing inside improperly ventilated or sealed buildings. Regardless of the source, exposure to VOCs could lead to significant health concerns from sick-building syndrome, 'leukemia houses,' in-hospital fungemia cases or occupation-associated cancer epidemics due to aflatoxicosis. Innovative 21st-century building materials could offer solutions to these challenges. We propose that volcanic materials, clays and minerals (volcanic tuff, modified clay montmorillonite and mineral clinoptilolite), in their original or chemically modified form, could act like synthetic lungs in building walls, breathing and filtering VOCs, and thus limiting human exposure to disease.

  20. Summer indoor heat exposure and respiratory and cardiovascular distress calls in New York City, NY, U.S.

    Science.gov (United States)

    Uejio, C K; Tamerius, J D; Vredenburg, J; Asaeda, G; Isaacs, D A; Braun, J; Quinn, A; Freese, J P

    2016-08-01

    Most extreme heat studies relate outdoor weather conditions to human morbidity and mortality. In developed nations, individuals spend ~90% of their time indoors. This pilot study investigated the indoor environments of people receiving emergency medical care in New York City, NY, U.S., from July to August 2013. The first objective was to determine the relative influence of outdoor conditions as well as patient characteristics and neighborhood sociodemographics on indoor temperature and specific humidity (N = 764). The second objective was to determine whether cardiovascular or respiratory cases experience hotter and more humid indoor conditions as compared to controls. Paramedics carried portable sensors into buildings where patients received care to passively monitor indoor temperature and humidity. The case-control study compared 338 respiratory cases, 291 cardiovascular cases, and 471 controls. Intuitively, warmer and sunnier outdoor conditions increased indoor temperatures. Older patients who received emergency care tended to occupy warmer buildings. Indoor-specific humidity levels quickly adjusted to outdoor conditions. Indoor heat and humidity exposure above a 26 °C threshold increased (OR: 1.63, 95% CI: 0.98-2.68, P = 0.056), but not significantly, the proportion of respiratory cases. Indoor heat exposures were similar between cardiovascular cases and controls. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.