WorldWideScience

Sample records for control room modernization

  1. Using a Research Simulator for Validating Control Room Modernization Concepts

    Energy Technology Data Exchange (ETDEWEB)

    Ronald L. Boring; Vivek Agarwal; Julius J. Persensky; Jeffrey C. Joe

    2012-05-01

    The Light Water Reactor Sustainability Program is a research, development, and deployment program sponsored by the United States Department of Energy. The program is operated in close collaboration with industry research and development programs to provide the technical foundations for licensing and managing the long-term, safe, and economical operation of nuclear power plants that are currently in operation. Advanced instrumentation and control (I&C) technologies are needed to support the continued safe and reliable production of power from nuclear energy systems during sustained periods of operation up to and beyond their expected licensed lifetime. This requires that new capabilities to achieve process control be developed and eventually implemented in existing nuclear control rooms. It also requires that approaches be developed and proven to achieve sustainability of I&C systems throughout the period of extended operation. Idaho National Laboratory (INL) is working closely with nuclear utilities to develop technologies and solutions to help ensure the safe life extension of current reactors. One of the main areas of focus is control room modernization. Current analog control rooms are growing obsolete, and it is difficult for utilities to maintain them. Using its reconfigurable control room simulator adapted from a training simulator, INL serves as a neutral test bed for implementing new control room system technologies and assisting in control room modernization efforts across.

  2. COMMERCIAL UTILITY PERSPECTIVES ON NUCLEAR POWER PLANT CONTROL ROOM MODERNIZATION

    Energy Technology Data Exchange (ETDEWEB)

    Jeffrey C. Joe; Ronald L. Boring; Julius J. Persensky

    2012-07-01

    Commercial nuclear power plants (NPPs) in the United States need to modernize their main control rooms (MCR). Many NPPs have done partial upgrades with some success and with some challenges. The Department of Energy’s (DOE) Light Water Reactor Sustainability (LWRS) Program, and in particular the Advanced Instrumentation and Controls (I&C) and Information Systems Technologies Research and Development (R&D) Pathway within LWRS, is designed to assist commercial nuclear power industry with their MCR modernization efforts. As part of this framework, a survey was issued to utility representatives of the LWRS Program Advanced Instrumentation, Information, and Control Systems/Technologies (II&C) Utility Working Group to obtain their views on a range of issues related to MCR modernization, including: drivers, barriers, and technology options, and the effects these aspects will have on concepts of operations, modernization strategies, and staffing. This paper summarizes the key survey results and discusses their implications.

  3. Human Factors Engineering Aspects of Modifications in Control Room Modernization

    Energy Technology Data Exchange (ETDEWEB)

    Hugo, Jacques; Clefton, Gordon; Joe, Jeffrey

    2017-06-01

    This report describes the basic aspects of control room modernization projects in the U.S. nuclear industry and the need for supplementary guidance on the integration of human factors considerations into the licensing and regulatory aspects of digital upgrades. The report pays specific attention to the integration of principles described in NUREG-0711 (Human Factors Engineering Program Review Model) and how supplementary guidance can help to raise general awareness in the industry regarding the complexities of control room modernization projects created by many interdependent regulations, standards and guidelines. The report also describes how human factors engineering principles and methods provided by various resources and international standards can help in navigating through the process of licensing digital upgrades. In particular, the integration of human factors engineering guidance and requirements into the process of licensing digital upgrades can help reduce uncertainty related to development of technical bases for digital upgrades that will avoid the introduction of new failure modes.

  4. First-of-A-Kind Control Room Modernization Project Plan

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, Kenneth David [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-02-01

    This project plan describes a comprehensive approach to the design of an end-state concept for a modernized control room for Palo Verde. It describes the collaboration arrangement between the DOE LWRS Program Control Room Modernization Project and the APS Palo Verde Nuclear Generating Station. It further describes the role of other collaborators, including the Institute for Energy Technology (IFE) and the Electric Power Research Institute (EPRI). It combines advanced tools, methodologies, and facilities to enable a science-based approach to the validation of applicable engineering and human factors principles for nuclear plant control rooms. It addresses the required project results and documentation to demonstrate compliance with regulatory requirements. It describes the project tasks that will be conducted in the project, and the deliverable reports that will be developed through these tasks. This project plan will be updated as new tasks are added and as project milestones are completed. It will serve as an ongoing description on the project both for project participants and for industry stakeholders.

  5. A Business Case for Nuclear Plant Control Room Modernization

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, Ken [Idaho National Lab. (INL), Idaho Falls, ID (United States); Lawrie, Sean [Idaho National Lab. (INL), Idaho Falls, ID (United States); Niedermuller, Josef M. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-06-01

    This paper presents a generic business case for implementation of technology that supports Control Room Modernization (CRM). The analysis presented in two forms; 1) a standalone technology upgrade, and 2) a technology upgrade that is built upon and incremental to a prior business case created for Mobile Work Packages (MWP). The business case contends that advanced communication and networking and analytical technologies will allow NPP to conduct control room operations with improved focus by reducing human factors and redundant manpower, and therefore operate with fewer errors. While some labor savings can be harvested in terms of overtime, the majority of savings are demonstrated as reduced time to take the plant off line and bring back on line in support of outages. The benefits are quantified to a rough order of magnitude that provides directional guidance to NPPs that are interested in developing a similar business case. This business case focuses on modernization of the operator control room and does not consider a complete overhaul and modernization of a plants instrument and control systems. While operators may be considering such an investment at their plants, the sizable capital investment required is not likely supported by a cost/benefit analysis alone. More likely, it is driven by obsolescence and reliability issues, and requires consideration of mechanical condition of plant systems, capital depreciation, financing, relicensing and overall viability of the plant asset over a 20-year horizon in a competitive market. Prior studies [REF] have indicated that such a modernization of plant I&C systems, alone or as part of a larger modernization effort, can yield very significant reductions in O&M costs. However, the depth of research and analysis required to develop a meaningful business case for a plant modernization effort is well beyond the scope of this study. While CRM as considered in this study can be easily integrated as part of grander plant

  6. Baseline Evaluations to Support Control Room Modernization at Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Boring, Ronald L.; Joe, Jeffrey C.

    2015-02-01

    For any major control room modernization activity at a commercial nuclear power plant (NPP) in the U.S., a utility should carefully follow the four phases prescribed by the U.S. Nuclear Regulatory Commission in NUREG-0711, Human Factors Engineering Program Review Model. These four phases include Planning and Analysis, Design, Verification and Validation, and Implementation and Operation. While NUREG-0711 is a useful guideline, it is written primarily from the perspective of regulatory review, and it therefore does not provide a nuanced account of many of the steps the utility might undertake as part of control room modernization. The guideline is largely summative—intended to catalog final products—rather than formative—intended to guide the overall modernization process. In this paper, we highlight two crucial formative sub-elements of the Planning and Analysis phase specific to control room modernization that are not covered in NUREG-0711. These two sub-elements are the usability and ergonomics baseline evaluations. A baseline evaluation entails evaluating the system as-built and currently in use. The usability baseline evaluation provides key insights into operator performance using the control system currently in place. The ergonomics baseline evaluation identifies possible deficiencies in the physical configuration of the control system. Both baseline evaluations feed into the design of the replacement system and subsequent summative benchmarking activities that help ensure that control room modernization represents a successful evolution of the control system.

  7. Light Water Reactor Sustainability Program A Reference Plan for Control Room Modernization: Planning and Analysis Phase

    Energy Technology Data Exchange (ETDEWEB)

    Jacques Hugo; Ronald Boring; Lew Hanes; Kenneth Thomas

    2013-09-01

    The U.S. Department of Energy’s Light Water Reactor Sustainability (LWRS) program is collaborating with a U.S. nuclear utility to bring about a systematic fleet-wide control room modernization. To facilitate this upgrade, a new distributed control system (DCS) is being introduced into the control rooms of these plants. The DCS will upgrade the legacy plant process computer and emergency response facility information system. In addition, the DCS will replace an existing analog turbine control system with a display-based system. With technology upgrades comes the opportunity to improve the overall human-system interaction between the operators and the control room. To optimize operator performance, the LWRS Control Room Modernization research team followed a human-centered approach published by the U.S. Nuclear Regulatory Commission. NUREG-0711, Rev. 3, Human Factors Engineering Program Review Model (O’Hara et al., 2012), prescribes four phases for human factors engineering. This report provides examples of the first phase, Planning and Analysis. The three elements of Planning and Analysis in NUREG-0711 that are most crucial to initiating control room upgrades are: • Operating Experience Review: Identifies opportunities for improvement in the existing system and provides lessons learned from implemented systems. • Function Analysis and Allocation: Identifies which functions at the plant may be optimally handled by the DCS vs. the operators. • Task Analysis: Identifies how tasks might be optimized for the operators. Each of these elements is covered in a separate chapter. Examples are drawn from workshops with reactor operators that were conducted at the LWRS Human System Simulation Laboratory HSSL and at the respective plants. The findings in this report represent generalized accounts of more detailed proprietary reports produced for the utility for each plant. The goal of this LWRS report is to disseminate the technique and provide examples sufficient to

  8. A HUMAN FACTORS META MODEL FOR U.S. NUCLEAR POWER PLANT CONTROL ROOM MODERNIZATION

    Energy Technology Data Exchange (ETDEWEB)

    Joe, Jeffrey C.

    2017-03-01

    Over the last several years, the United States (U.S.) Department of Energy (DOE) has sponsored human factors research and development (R&D) and human factors engineering (HFE) activities through its Light Water Reactor Sustainability (LWRS) program to modernize the main control rooms (MCR) of commercial nuclear power plants (NPP). Idaho National Laboratory (INL), in partnership with numerous commercial nuclear utilities, has conducted some of this R&D to enable the life extension of NPPs (i.e., provide the technical basis for the long-term reliability, productivity, safety, and security of U.S. NPPs). From these activities performed to date, a human factors meta model for U.S. NPP control room modernization can now be formulated. This paper discusses this emergent HFE meta model for NPP control room modernization, with the goal of providing an integrated high level roadmap and guidance on how to perform human factors R&D and HFE for those in the U.S. nuclear industry that are engaging in the process of upgrading their MCRs.

  9. Human factor engineering based design and modernization of control rooms with new I and C systems

    Energy Technology Data Exchange (ETDEWEB)

    Larraz, J.; Rejas, L. [New Control Room Design Dept., Av. Montes de Oca, 1, 28703 San Sebastian de los Reyes-Madrid (Spain); Ortega, F. [Control Room and Simulation Dept., Av. Montes de Oca, 1, 28703 San Sebastian de los Reyes-Madrid (Spain)

    2012-07-01

    Instrumentation and Control (I and C) systems of the latest nuclear power plants are based on the use of digital technology, distributed control systems and the integration of information in data networks (Distributed Control and Instrumentation Systems). This has a repercussion on Control Rooms (CRs), where the operations and monitoring interfaces correspond to these systems. These technologies are also used in modernizing I and C systems in currently operative nuclear power plants. The new interfaces provide additional capabilities for operation and supervision, as well as a high degree of flexibility, versatility and reliability. An example of this is the implementation of solutions such as compact stations, high level supervision screens, overview displays, computerized procedures, new operational support systems or intelligent alarms processing systems in the modernized Man-Machine Interface (MMI). These changes in the MMI are accompanied by newly added Software (SW) controls and new solutions in automation. Tecnatom has been leading various projects in this area for several years, both in Asian countries and in the United States, using in all cases international standards from which Tecnatom own methodologies have been developed and optimized. The experience acquired in applying this methodology to the design of new control rooms is to a large extent applicable also to the modernization of current control rooms. An adequate design of the interface between the operator and the systems will facilitate safe operation, contribute to the prompt identification of problems and help in the distribution of tasks and communications between the different members of the operating shift. Based on Tecnatom experience in the field, this article presents the methodological approach used as well as the most relevant aspects of this kind of project. (authors)

  10. A HUMAN FACTORS ENGINEERING PROCESS TO SUPPORT HUMAN-SYSTEM INTERFACE DESIGN IN CONTROL ROOM MODERNIZATION

    Energy Technology Data Exchange (ETDEWEB)

    Kovesdi, C.; Joe, J.; Boring, R.

    2017-05-01

    The primary objective of the United States (U.S.) Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) program is to sustain operation of the existing commercial nuclear power plants (NPPs) through a multi-pathway approach in conducting research and development (R&D). The Advanced Instrumentation, Information, and Control (II&C) System Technologies pathway conducts targeted R&D to address aging and reliability concerns with legacy instrumentation and control (I&C) and other information systems in existing U.S. NPPs. Control room modernization is an important part following this pathway, and human factors experts at Idaho National Laboratory (INL) have been involved in conducting R&D to support migration of new digital main control room (MCR) technologies from legacy analog and legacy digital I&C. This paper describes a human factors engineering (HFE) process that supports human-system interface (HSI) design in MCR modernization activities, particularly with migration of old digital to new digital I&C. The process described in this work is an expansion from the LWRS Report INL/EXT-16-38576, and is a requirements-driven approach that aligns with NUREG-0711 requirements. The work described builds upon the existing literature by adding more detail around key tasks and decisions to make when transitioning from HSI Design into Verification and Validation (V&V). The overall objective of this process is to inform HSI design and elicit specific, measurable, and achievable human factors criteria for new digital technologies. Upon following this process, utilities should have greater confidence with transitioning from HSI design into V&V.

  11. Light Water Reactor Sustainability Program Operator Performance Metrics for Control Room Modernization: A Practical Guide for Early Design Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Ronald Boring; Roger Lew; Thomas Ulrich; Jeffrey Joe

    2014-03-01

    As control rooms are modernized with new digital systems at nuclear power plants, it is necessary to evaluate the operator performance using these systems as part of a verification and validation process. There are no standard, predefined metrics available for assessing what is satisfactory operator interaction with new systems, especially during the early design stages of a new system. This report identifies the process and metrics for evaluating human system interfaces as part of control room modernization. The report includes background information on design and evaluation, a thorough discussion of human performance measures, and a practical example of how the process and metrics have been used as part of a turbine control system upgrade during the formative stages of design. The process and metrics are geared toward generalizability to other applications and serve as a template for utilities undertaking their own control room modernization activities.

  12. Anthropometric Considerations in the Modernized Main Control Room: Application to a Virtual Nuclear Power Plant Control Panel

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Chih Wei; Cheng, Tsung Chieh [Institute of Nuclear Energy Research, Taoyuan (China); Lin, Chiuhsiang Joe [Chung-Yuan Christian University, Chung Li (China)

    2011-08-15

    This study investigates the anthropometric considerations in the main control room (MCR) application to a virtual nuclear power plant (NPP) control panel. Influences of working postures and physical demands on the operational performance are also discussed. Finally, the present research provides a case example to illustrate the influences of anthropometric considerations on the control panel design for MCR operators by applying virtual reality (VR) technology. The MCR design primarily evolved in different countries. The datasets available is usually insufficient or inconsistent for the end users. To solve the upper mentioned problem, this study put emphasis on applying VR technology to anthropometric considerations support control panel design in the modernized MCR. Although the concept of applying VR technology on anthropometric considerations in this paper is related to the MCR in NPPs, it could be easily applied for the purposes of any type of control room in a similar manner.

  13. Design and modernization of control rooms according to new I and C systems based on HFE principles

    Energy Technology Data Exchange (ETDEWEB)

    Rejas, Luis; Larraz, Javier, E-mail: lrejas@tecnatom.e, E-mail: jlarraz@tecnatom.e [Tecnatom S.A., San Sebastian de los Reyes, Madrid (Spain). New Control Room Design Dept.; Ortega, Fernando, E-mail: fortega@tecnatom.e [Tecnatom S.A., San Sebastian de los Reyes, Madrid (Spain). Control Room and Simulation Dept.

    2011-07-01

    The use of new digital I and C systems in the design of new nuclear power plants, as well as the modernization of existing facilities, implies relevant changes in the control room design. New I and C systems provide new features that affect the control room operating concept. Therefore, a detailed analysis is required to take into consideration all the operating and human factors aspects. Based on Tecnatom experience in the field, this article presents the methodological approach used as well as the most relevant aspects of this kind of project. (author)

  14. APPLICATION OF EYE TRACKING FOR MEASUREMENT AND EVALUATION IN HUMAN FACTORS STUDIES IN CONTROL ROOM MODERNIZATION

    Energy Technology Data Exchange (ETDEWEB)

    Kovesdi, C.; Spielman, Z.; LeBlanc, K.; Rice, B.

    2017-05-01

    An important element of human factors engineering (HFE) pertains to measurement and evaluation (M&E). The role of HFE-M&E should be integrated throughout the entire control room modernization (CRM) process and be used for human-system performance evaluation and diagnostic purposes with resolving potential human engineering deficiencies (HEDs) and other human machine interface (HMI) design issues. NUREG-0711 describes how HFE in CRM should employ a hierarchical set of measures, particularly during integrated system validation (ISV), including plant performance, personnel task performance, situation awareness, cognitive workload, and anthropometric/ physiological factors. Historically, subjective measures have been primarily used since they are easier to collect and do not require specialized equipment. However, there are pitfalls with relying solely on subjective measures in M&E such that negatively impact reliability, sensitivity, and objectivity. As part of comprehensively capturing a diverse set of measures that strengthen findings and inferences made of the benefits from emerging technologies like advanced displays, this paper discusses the value of using eye tracking as an objective method that can be used in M&E. A brief description of eye tracking technology and relevant eye tracking measures is provided. Additionally, technical considerations and the unique challenges with using eye tracking in full-scaled simulations are addressed. Finally, this paper shares preliminary findings regarding the use of a wearable eye tracking system in a full-scale simulator study. These findings should help guide future full-scale simulator studies using eye tracking as a methodology to evaluate human-system performance.

  15. A Distributed Control System Prototyping Environment to Support Control Room Modernization

    Energy Technology Data Exchange (ETDEWEB)

    Lew, Roger Thomas [Idaho National Lab. (INL), Idaho Falls, ID (United States); Boring, Ronald Laurids [Idaho National Lab. (INL), Idaho Falls, ID (United States); Ulrich, Thomas Anthony [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-12-01

    Operators of critical processes, such as nuclear power production, must contend with highly complex systems, procedures, and regulations. Developing human-machine interfaces (HMIs) that better support operators is a high priority for ensuring the safe and reliable operation of critical processes. Human factors engineering (HFE) provides a rich and mature set of tools for evaluating the performance of HMIs, however the set of tools for developing and designing HMIs is still in its infancy. Here we propose a rapid prototyping approach for integrating proposed HMIs into their native environments before a design is finalized. This approach allows researchers and developers to test design ideas and eliminate design flaws prior to fully developing the new system. We illustrate this approach with four prototype designs developed using Microsoft’s Windows Presentation Foundation (WPF). One example is integrated into a microworld environment to test the functionality of the design and identify the optimal level of automation for a new system in a nuclear power plant. The other three examples are integrated into a full-scale, glasstop digital simulator of a nuclear power plant. One example demonstrates the capabilities of next generation control concepts; another aims to expand the current state of the art; lastly, an HMI prototype was developed as a test platform for a new control system currently in development at U.S. nuclear power plants. WPF possesses several characteristics that make it well suited to HMI design. It provides a tremendous amount of flexibility, agility, robustness, and extensibility. Distributed control system (DCS) specific environments tend to focus on the safety and reliability requirements for real-world interfaces and consequently have less emphasis on providing functionality to support novel interaction paradigms. Because of WPF’s large user-base, Microsoft can provide an extremely mature tool. Within process control applications,WPF is

  16. Human Factors and Modeling Methods in the Development of Control Room Modernization Concepts

    Energy Technology Data Exchange (ETDEWEB)

    Hugo, Jacques V.; Slay III, Lorenzo

    2017-06-01

    nuclear power plants. Although the nuclear industry has made steady improvement in outage optimization, each day of a refueling outage still represents an opportunity to save millions of dollars and each day an outage extends past its planned end date represents millions of dollars that may have been spent unnecessarily. Reducing planned outage duration or preventing outage extensions requires careful management of the outage schedule as well as constant oversight and monitoring of work completion during the outage execution. During a typical outage, there are typically more than 10,000 activities on the schedule that, if not managed efficiently, may cause expensive outage delays. Management of outages currently relies largely on paper-based resources and general-purpose office software. A typical tool currently used to monitor work performance is a burn-down curve, where total remaining activities are plotted against the baseline schedule to track bulk work completion progress. While these tools are useful, there is still considerable uncertainty during a typical outage that bulk work progress is adequate and therefore a lot of management time is spent analyzing the situation on a daily basis. This paper describes recent advances made in developing a framework for the design of visual outage information presentation, as well as an overview of the scientific principles that informed the development of the visualizations. To test the utility of advanced visual outage information presentation, an outage management dashboard software application was created as part of the Department of Energy’s Advanced Outage Control Center project. This dashboard is intended to present all the critical information an outage manager would need to understand the current status of a refueling outage. The dashboard presents the critical path, bulk work performance, key performance indicators, outage milestones and metrics relating current performance to historical performance

  17. Rethinking theatre in modern operating rooms.

    Science.gov (United States)

    Riley, Robin; Manias, Elizabeth

    2005-03-01

    Metaphor is a means through which a widely accepted meaning of a word is used in a different context to add understanding that would otherwise be difficult to conceive. Through etymological and metaphorical associations, we contend that aspects of "theatre" are still relevant in the modern operating rooms and that the use of dramaturgical metaphors can add another layer of understanding about the social reality in this setting. We begin by exploring the historical roots and derivation of the word theatre as it applied to anatomical dissection and surgery. Briefly, we touch on the work of Erving Goffman and examine how his work has been used by others to explore aspects of operating room nursing. Then, drawing on data from a postmodern ethnographic study that has been used to examine communication in operating room nursing, four dramaturgical metaphors are used to illustrate the argument. They are drama, the script and learning the lines, the show must go on, and changing between back stage and front stage. To conclude, the small amount of previously published literature on this topic is compared and contrasted, and the relevance of using dramaturgical metaphors to understand modern operating rooms is discussed. Being able to distinguish between the inherent drama in operating room work and the dramatic realisation of individuals who work within, can help operating room nurses to think differently about, and perhaps re-evaluate their social situation and how they function within it.

  18. PS Control Room

    CERN Multimedia

    CERN PhotoLab

    1963-01-01

    The good old PS Control Room, all manual. For each parameter, a knob or a button to control it; for each, a light or meter or oscilloscope to monitor it; carefully written pages serve as the data bank; phones and intercom for communication. D.Dekkers is at the microphone, M.Valvini sits in front.

  19. Local control room

    CERN Multimedia

    CERN PhotoLab

    1972-01-01

    Local control room in the ejection building : all electronics pertaining to proton distribution and concomitants such as beam gymnastics and diagnostics at high energies will eventually be gathered here. Shown is the first of two rows of fast ejection electronic racks. It includes only what is necessary for operation.

  20. Requirements for Control Room Computer-Based Procedures for use in Hybrid Control Rooms

    Energy Technology Data Exchange (ETDEWEB)

    Le Blanc, Katya Lee [Idaho National Lab. (INL), Idaho Falls, ID (United States); Oxstrand, Johanna Helene [Idaho National Lab. (INL), Idaho Falls, ID (United States); Joe, Jeffrey Clark [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-05-01

    Many plants in the U.S. are currently undergoing control room modernization. The main drivers for modernization are the aging and obsolescence of existing equipment, which typically results in a like-for-like replacement of analogue equipment with digital systems. However, the modernization efforts present an opportunity to employ advanced technology that would not only extend the life, but enhance the efficiency and cost competitiveness of nuclear power. Computer-based procedures (CBPs) are one example of near-term advanced technology that may provide enhanced efficiencies above and beyond like for like replacements of analog systems. Researchers in the LWRS program are investigating the benefits of advanced technologies such as CBPs, with the goal of assisting utilities in decision making during modernization projects. This report will describe the existing research on CBPs, discuss the unique issues related to using CBPs in hybrid control rooms (i.e., partially modernized analog control rooms), and define the requirements of CBPs for hybrid control rooms.

  1. Psychological and Physical Stress in Surgeons Operating in a Standard or Modern Operating Room

    DEFF Research Database (Denmark)

    Klein, M.; Andersen, L.P.H.; Gögenür, Ismayil

    2010-01-01

    Purpose: There have been no studies examining the effect of optimized ergonomic and technical environment on the psychological and physiological stress of the surgeon. The aim of this study was to examine whether optimized ergonomics and technical aids within a modern operating room (OR) affect...... psychological and physiological stress in experienced laparoscopic surgeons. Methods: This was a prospective case-controlled study including 10 experienced surgeons. Surgery was performed in 2 different ORs: a standard room and a modern room (OR1-suite, Karl Storz). The surgeons filled out questionnaires...

  2. In the LEAR control room

    CERN Multimedia

    1983-01-01

    View into the control room of the Low Energy Antiproton Ring (LEAR). Edgar Asseo (sitting) and Dieter Möhl and Georges Carron reflecting upon some beam dynamics (or hardware?) problem. Vassilis Agoritsas, in the background, leaning over a plan or a keyboard. LEAR in its early years (1982 to about 1990) was run from this local control room in building 363 close to the end of the PS South Hall, where the ring was installed. Later-on the operation was surveyed from the PS main control room.

  3. ISOLDE target zone control room

    CERN Multimedia

    2016-01-01

    Operating the ISOLDE target handling robots from the dedicated control room in building 197. Monitors showing the movements of the robots (GPS in this case) in the target zone. The footage shows the actual operation by the operator as well as the different equipment such as camera electronics, camera motor controls, camera monitors and Kuka robot controls touch panel.

  4. Modern tandem control systems

    Science.gov (United States)

    Lutz, J. R.; Marsaudon, J. C.

    1993-04-01

    Nowadays, tandem electrostatic accelerators can benefit greatly from the growing possibilities provided by modern control facilities. Controlling an electrostatic accelerator first requires the solution of technological problems raised by the necessity of fitting inside the tank equipment which is highly stressed by the physical environment. Then, these controls can take advantage of new techniques which appear on the market. Present computer technology provides cheap powerful workstations for efficient operator interfacing, and new modular and distributed control concepts have been developed for general use in experimental physics, in data acquisition and in control systems. The general trend towards standardization is now accepted for both hardware and software and this brings benefits to the designer and the user.

  5. IGISOL control system modernization

    Energy Technology Data Exchange (ETDEWEB)

    Koponen, J., E-mail: jukka.ae.koponen@jyu.fi; Hakala, J.

    2016-06-01

    Since 2010, the IGISOL research facility at the Accelerator laboratory of the University of Jyväskylä has gone through major changes. Comparing the new IGISOL4 facility to the former IGISOL3 setup, the size of the facility has more than doubled, the length of the ion transport line has grown to about 50 m with several measurement setups and extension capabilities, and the accelerated ions can be fed to the facility from two different cyclotrons. The facility has evolved to a system comprising hundreds of manual, pneumatic and electronic devices. These changes have prompted the need to modernize also the facility control system taking care of monitoring and transporting the ion beams. In addition, the control system is also used for some scientific data acquisition tasks. Basic guidelines for the IGISOL control system update have been remote control, safety, usability, reliability and maintainability. Legacy components have had a major significance in the control system hardware and for the renewed control system software the Experimental Physics and Industrial Control System (EPICS) has been chosen as the architectural backbone.

  6. Establishing a value chain for human factors in nuclear power plantcontrol room modernization

    Energy Technology Data Exchange (ETDEWEB)

    Joe, Jeffrey Clark [Idaho National Laboratory; Thomas, Kenneth David [Idaho National Laboratory; Boring, Ronald Laurids [Idaho National Laboratory

    2015-07-01

    Commercial nuclear power plants in the United States (U.S.) have operated reliably and efficiently for decades. With the life extensions of plants now being planned for operation beyond their original operating licenses, there are opportunities to achieve even greater efficiencies, while maintaining high operational reliabilities, with strategic, risk- and economically-informed, upgrades to plant systems and infrastructure. The U.S. Department of Energy’s Light Water Reactor Sustainability (LWRS) program supports the commercial nuclear industry’s modernization efforts through research and development (R&D) activities across many areas to help establish the technical and economic bases for modernization activities. The Advanced Instrumentation, Information, and Control Systems Technologies pathway is one R&D focus area for the LWRS program, and has researchers at Idaho National Laboratory working with select utility partners to use human factors and instrumentation and controls R&D to help modernize the plant’s main control room. However, some in the nuclear industry have not been as enthusiastic about using human factors R&D to inform life extension decision making. Part of the reason for this may stem from uncertainty decision-makers have regarding how human factors fits into the value chain for nuclear power plant control room modernization. This paper reviews past work that has attempted to demonstrate the value of human factors, and then describes the value chain concept, how it applies to control room modernization, and then makes a case for how and why human factors is an essential link in the modernization value chain.

  7. CHALLENGES OF MODERN CONTROL THEORY

    Science.gov (United States)

    The fundamental objective of the new scientific discipline called ’ control theory ’ is that of modifying the behavior of a system subject to various...possible contributions of modern control theory to the biomedical domain are briefly indicated.

  8. A Research Framework for Demonstrating Benefits of Advanced Control Room Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Le Blanc, Katya [Idaho National Lab. (INL), Idaho Falls, ID (United States); Boring, Ronald [Idaho National Lab. (INL), Idaho Falls, ID (United States); Joe, Jeffrey [Idaho National Lab. (INL), Idaho Falls, ID (United States); Hallbert, Bruce [Idaho National Lab. (INL), Idaho Falls, ID (United States); Thomas, Kenneth [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-12-01

    Control Room modernization is an important part of life extension for the existing light water reactor fleet. None of the 99 currently operating commercial nuclear power plants in the U.S. has completed a full-scale control room modernization to date. A full-scale modernization might, for example, entail replacement of all analog panels with digital workstations. Such modernizations have been undertaken successfully in upgrades in Europe and Asia, but the U.S. has yet to undertake a control room upgrade of this magnitude. Instead, nuclear power plant main control rooms for the existing commercial reactor fleet remain significantly analog, with only limited digital modernizations. Previous research under the U.S. Department of Energy’s Light Water Reactor Sustainability Program has helped establish a systematic process for control room upgrades that support the transition to a hybrid control. While the guidance developed to date helps streamline the process of modernization and reduce costs and uncertainty associated with introducing digital control technologies into an existing control room, these upgrades do not achieve the full potential of newer technologies that might otherwise enhance plant and operator performance. The aim of the control room benefits research presented here is to identify previously overlooked benefits of modernization, identify candidate technologies that may facilitate such benefits, and demonstrate these technologies through human factors research. This report serves as an outline for planned research on the benefits of greater modernization in the main control rooms of nuclear power plants.

  9. Baseline Study Methodology for Future Phases of Research on Nuclear Power Plant Control Room Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Le Blanc, Katya Lee [Idaho National Lab. (INL), Idaho Falls, ID (United States); Bower, Gordon Ross [Idaho National Lab. (INL), Idaho Falls, ID (United States); Hill, Rachael Ann [Idaho National Lab. (INL), Idaho Falls, ID (United States); Spielman, Zachary Alexander [Idaho National Lab. (INL), Idaho Falls, ID (United States); Rice, Brandon Charles [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-07-01

    In order to provide a basis for industry adoption of advanced technologies, the Control Room Upgrades Benefits Research Project will investigate the benefits of including advanced technologies as part of control room modernization This report describes the background, methodology, and research plan for the first in a series of full-scale studies to test the effects of advanced technology in NPP control rooms. This study will test the effect of Advanced Overview Displays in the partner Utility’s control room simulator

  10. Noise control considerations for patient rooms

    Science.gov (United States)

    Davenny, Benjamin

    2005-09-01

    The patient room envelope is a path between outside noise sources and the patient receiver. Within the patient room there are several sources including televisions, clinical monitor alarms, medical pumps, etc. Noise control in patient rooms relies on a combination of the sound transmission loss of the patient room envelope and the level of background sound at the patient's head. Guidelines published by the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE), American Institute of Architects (AIA), and the U.S. Department of Defense for background noise and sound transmission loss in patient rooms will be discussed. Appropriate levels, spectra, and temporal characteristics of background sound at the patient head location may be helpful in raising the threshold of annoying sounds. Various means of personal hearing protection for patients will be discussed. Sound-pressure levels in patient rooms reported in previous literature will also be discussed.

  11. Evaporation Controlled Emission in Ventilated Rooms

    DEFF Research Database (Denmark)

    Topp, Claus; Nielsen, Peter V.; Heiselberg, Per

    -scale ventilated room when the emission is fully or partly evaporation controlled. The objective of the present research work has been to investigate the change of emission rates from small-scale experiments to full-scale ventilated rooms and to investigate the influence of the local air velocity field near...

  12. Virtual Training of Compressor Control Room Project

    Data.gov (United States)

    National Aeronautics and Space Administration — MYMIC will analyze, design, develop and evaluate the Virtual Control Room – Compressor Station (VCoR-CS) training system. VCoR-CS will provide procedural...

  13. Management control in modern organizations

    Directory of Open Access Journals (Sweden)

    Šljivić Slavoljub

    2015-01-01

    Full Text Available This paper deals with management control as an important instrument for managing performances in modern organizations. The paper indicates to the circumstances in which classical theory of management control was created, and describes its process of functioning, with the specifics in large organizations. The aim is to point to some open questions and directions of further development of the management control, as well as to at least partially fill the gap that exists in the domestic literature. The conclusion is that the existing management control framework remains still valid. Open questions can be best resolved within the concept that observes this matter as a 'package' of different control systems, not just those that are oriented to accounting-based performance measures.

  14. ISOLDE target zone control room HD

    CERN Multimedia

    2016-01-01

    Operating the ISOLDE target handling robots from the dedicated control room in building 197. Monitors showing the movements of the robots (GPS in this case) in the target zone. The footage shows the actual operation by the operator as well as the different equipment such as camera electronics, camera motor controls, camera monitors and Kuka robot controls touch panel.

  15. Software Support during a Control Room Upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Michele Joyce; Michael Spata; Thomas Oren; Anthony Cuffe; Theo McGuckin; Isadoro Carlino; C. Higgins; Harry Fanning; Matthew Bickley; Brian Bevins

    2005-09-21

    In 2004, after 14 years of accelerator operations and commissioning, Jefferson Lab renovated its main control room. Changes in technology and lessons learned during those 14 years drove the control room redesign in a new direction, one that optimizes workflow and makes critical information and controls available to everyone in the control room. Fundamental changes in a variety of software applications were required to facilitate the new operating paradigm. A critical component of the new control room design is a large-format video wall that is used to make a variety of operating information available to everyone in the room. Analog devices such as oscilloscopes and function generators are now displayed on the video wall through two crosspoint switchers: one for analog signals and another for video signals. A new software GUI replaces manual configuration of the oscilloscopes and function generators and helps automate setup. Monitoring screens, customized for the video wall, now make important operating information visible to everyone, not just a single operator. New alarm handler software gives any operator, on any workstation, access to all alarm handler functionality, and multiple users can now contribute to a single electronic logbook entry. To further support the shift to distributed access and control, many applications have been redesigned to run on servers instead of on individual workstations.

  16. Controllability of room air temperature. Huonelaempoetilan saeaetoe

    Energy Technology Data Exchange (ETDEWEB)

    Laitila, P.; Katajisto, K.; Karjalainen, S.; Lassila, K. (Valtion Teknillinen Tutkimuskeskus, Espoo (Finland). LVI-tekniikan Laboratorio)

    1991-01-15

    At first, the control loop of room air temperature was studied as a unit process to find out the characteristic controllability factors of the process as well as possible. Step-response tests were made to the process. Furthermore, the choice of the control law, the adjustment of the controller parameters and the applicability of the controller parameters were analyzed. The results are based mainly on the simulation studies of the office building using the TRNSYS, HVACSIM{sup +} and PIPNET simulation programs. When making a step-change, e.g. to inlet air temperature, it takes a long time before the room air temperature achieves its final steady state. In addition, the gain of the process is slow. The time constant of the process is 30 min - 100 min. The steady state in terms of controllability is achieved in approximately four hours. The control difficulty of the process is significant below 0,1 independently of a heating or air conditioning system of the room space. The centralized and the distributed control of the room air temperature was studied as well. When the loads in different spaces differed greatly from one another, temperature conditions could not be controlled using centralized control. In that case the distributed temperature control based on room or zone space should be used. The integrated control of the air conditioning and heating systems proved to be quite difficult on the basis of the simulation studies especially when external loads vary a lot. The measurements made in a building in prevailing conditions did not support the integrated control of the air conditioning and heating systems. However, the heating system was under-dimensioned compared to the air conditioning system.

  17. Cooperative research for human factors review of advanced control rooms

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jung Woon; Park, Jae Chang; Lee, Yong Hee; Oh, In Seok; Lee, Hyun Chul

    2000-12-01

    This project has been performed as cooperative research between KAERI and USNRC. Human factors issues related to soft controls, which is one of key features of advanced HSI, are identified in this project. The issues are analyzed for the evaluation approaches in either experimental or analytical ways. Also, issues requiring additional researches for the evaluation of advanced HSI are identified in the areas of advanced information systems design, computer-based procedure systems, soft controls, human systems interface and plant modernization process, and maintainability of digital systems. The issues are analyzed to discriminate the urgency of researches on it to high, medium, and low levels in consideration of advanced HSI development status in Korea, and some of the issues that can be handled by experimental researches are identified. Additionally, an experimental study is performed to compare operator's performance on human error detection in advanced control rooms vs. in conventional control rooms. It is found that advanced control rooms have several design characteristics hindering operator's error detection performance compared to conventional control rooms.

  18. Dedication instrumentation control rooms; Dedicacion instrumentacion salas de control

    Energy Technology Data Exchange (ETDEWEB)

    Lopez, M. I.; Vilas, J. L.; Bravo, J. L.; Rejas, L.; Corrales, C.

    2013-07-01

    Tecnatom has participated since 2010 in the project, led by IOM (USA), design and supply of Control rooms of NPPS Chinese with CPR-1000 design. Among the various activities, the dedication of the components of the Control rooms (BUP - Back - up Panel and ECP - Emergency Control Panel) is joining the American requirements with the criteria of the French regulations.

  19. Verification and Validation of Digitally Upgraded Control Rooms

    Energy Technology Data Exchange (ETDEWEB)

    Boring, Ronald [Idaho National Lab. (INL), Idaho Falls, ID (United States); Lau, Nathan [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-09-01

    As nuclear power plants undertake main control room modernization, a challenge is the lack of a clearly defined human factors process to follow. Verification and validation (V&V) as applied in the nuclear power community has tended to involve efforts such as integrated system validation, which comes at the tail end of the design stage. To fill in guidance gaps and create a step-by-step process for control room modernization, we have developed the Guideline for Operational Nuclear Usability and Knowledge Elicitation (GONUKE). This approach builds on best practices in the software industry, which prescribe an iterative user-centered approach featuring multiple cycles of design and evaluation. Nuclear regulatory guidance for control room design emphasizes summative evaluation—which occurs after the design is complete. In the GONUKE approach, evaluation is also performed at the formative stage of design—early in the design cycle using mockups and prototypes for evaluation. The evaluation may involve expert review (e.g., software heuristic evaluation at the formative stage and design verification against human factors standards like NUREG-0700 at the summative stage). The evaluation may also involve user testing (e.g., usability testing at the formative stage and integrated system validation at the summative stage). An additional, often overlooked component of evaluation is knowledge elicitation, which captures operator insights into the system. In this report we outline these evaluation types across design phases that support the overall modernization process. The objective is to provide industry-suitable guidance for steps to be taken in support of the design and evaluation of a new human-machine interface (HMI) in the control room. We suggest the value of early-stage V&V and highlight how this early-stage V&V can help improve the design process for control room modernization. We argue that there is a need to overcome two shortcomings of V&V in current practice

  20. Measuring Human Performance in Simulated Nuclear Power Plant Control Rooms Using Eye Tracking

    Energy Technology Data Exchange (ETDEWEB)

    Kovesdi, Casey Robert [Idaho National Lab. (INL), Idaho Falls, ID (United States); Rice, Brandon Charles [Idaho National Lab. (INL), Idaho Falls, ID (United States); Bower, Gordon Ross [Idaho National Lab. (INL), Idaho Falls, ID (United States); Spielman, Zachary Alexander [Idaho National Lab. (INL), Idaho Falls, ID (United States); Hill, Rachael Ann [Idaho National Lab. (INL), Idaho Falls, ID (United States); LeBlanc, Katya Lee [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-11-01

    Control room modernization will be an important part of life extension for the existing light water reactor fleet. As part of modernization efforts, personnel will need to gain a full understanding of how control room technologies affect performance of human operators. Recent advances in technology enables the use of eye tracking technology to continuously measure an operator’s eye movement, which correlates with a variety of human performance constructs such as situation awareness and workload. This report describes eye tracking metrics in the context of how they will be used in nuclear power plant control room simulator studies.

  1. Benefits of Advanced Control Room Technologies: Phase One Upgrades to the HSSL, Research Plan, and Performance Measures

    Energy Technology Data Exchange (ETDEWEB)

    Le Blanc, Katya [Idaho National Lab. (INL), Idaho Falls, ID (United States); Joe, Jeffrey [Idaho National Lab. (INL), Idaho Falls, ID (United States); Rice, Brandon [Idaho National Lab. (INL), Idaho Falls, ID (United States); Ulrich, Thomas [Idaho National Lab. (INL), Idaho Falls, ID (United States); Boring, Ronald [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-05-01

    Control Room modernization is an important part of life extension for the existing light water reactor fleet. None of the 99 currently operating commercial nuclear power plants in the U.S. has completed a full-scale control room modernization to date. A full-scale modernization might, for example, entail replacement of all analog panels with digital workstations. Such modernizations have been undertaken successfully in upgrades in Europe and Asia, but the U.S. has yet to undertake a control room upgrade of this magnitude. Instead, nuclear power plant main control rooms for the existing commercial reactor fleet remain significantly analog, with only limited digital modernizations. Previous research under the U.S. Department of Energy’s Light Water Reactor Sustainability Program has helped establish a systematic process for control room upgrades that support the transition to a hybrid control room. While the guidance developed to date helps streamline the process of modernization and reduce costs and uncertainty associated with introducing digital control technologies into an existing control room, these upgrades do not achieve the full potential of newer technologies that might otherwise enhance plant and operator performance. The aim of the control room benefits research is to identify previously overlooked benefits of modernization, identify candidate technologies that may facilitate such benefits, and demonstrate these technologies through human factors research. This report describes the initial upgrades to the HSSL and outlines the methodology for a pilot test of the HSSL configuration.

  2. PS Main Control Room (partial view)

    CERN Multimedia

    1974-01-01

    Jean-Pierre Potier (turning buttons) and Bertran Frammery (telephoning) on shift. The 26 GeV Synchrotron and later also its related machines (Linacs 1,2,3; PS-Booster; LEP-Injector Linacs and Electron-Positron Accumulator; Antiproton Accumulator, Antiproton Collector, Low Energy Antiproton Ring and more recently Antiproton Decelerator) were all controlled from the PS control room situated on the Meyrin site. The SPS and LEP were controlled from a separat control centre on the Prevessin site. In 2005 all controls were transferred to the Prevessin centre.

  3. Human Factors Guidance for Control Room and Digital Human-System Interface Design and Modification, Guidelines for Planning, Specification, Design, Licensing, Implementation, Training, Operation and Maintenance

    Energy Technology Data Exchange (ETDEWEB)

    R. Fink, D. Hill, J. O' Hara

    2004-11-30

    Nuclear plant operators face a significant challenge designing and modifying control rooms. This report provides guidance on planning, designing, implementing and operating modernized control rooms and digital human-system interfaces.

  4. EARLY-STAGE DESIGN AND EVALUATION FOR NUCLEAR POWER PLANT CONTROL ROOM UPGRADES

    Energy Technology Data Exchange (ETDEWEB)

    Ronald L. Boring; Jeffrey C. Joe; Thomas A. Ulrich; Roger T. Lew

    2015-03-01

    As control rooms are modernized with new digital systems at nuclear power plants, it is necessary to evaluate operator performance with these systems as part of a verification and validation process. While there is regulatory and industry guidance for some modernization activities, there are no well defined standard processes or predefined metrics available for assessing what is satisfactory operator interaction with new systems, especially during the early design stages. This paper proposes a framework defining the design process and metrics for evaluating human system interfaces as part of control room modernization. The process and metrics are generalizable to other applications and serve as a guiding template for utilities undertaking their own control room modernization activities.

  5. Recent Development in the ATLAS Control Room

    CERN Multimedia

    Armen Vartapetian

    Only recently the name ATLAS Control Room (ACR) was more associated with the building at Point 1 (SCX1) than with the real thing. But just within the last several months, with the installation of the ACR hardware, that perception has changed significantly. The recently furnished ATLAS control room. But first of all, if you are not familiar with the ATLAS experimental site and are interested in visiting the ATLAS control room to see the place that in the near future will become the brain of the detector operations, it is quite easy to do so. You don't even need safety helmet or shoes! The ACR is located on the ground floor of a not so typical, glass-covered building in Point 1. The building number on the CERN map is 3162, or SCX1 as we call it. It is also easy to recognize that building by its shiny appearance within the cluster of Point 1 buildings if you are driving from Geneva. Final design and prototyping of the ACR hardware started at the beginning of 2006. Evaluation of the chosen hardware confi...

  6. Influence of advanced room -and building automation and optimized operation control on the energy efficiency of buildings; Einfluss moderner Raum- und Gebaeudeautomation und optimierter Betriebsfuehrung auf die Energieeffizienz von Gebaeuden

    Energy Technology Data Exchange (ETDEWEB)

    Knoll, P.; Peters, B.; Becker, M. [Hochschule Biberach (Germany). Fachgebiet Gebaeudeautomation

    2008-07-01

    There is an increasing awareness of using our energy resources more efficiently which also leads to the finding of the importance of energy-efficient building services and operation. Unfortunately, we often restrict ourselves looking only at the costs of the investment itself instead of taking into account also the costs during the long time of building operation. In particular this is an obvious fact to decisions of investments for room and building automation equipment. However, building automation and control systems (BACS) deliver high potentials for energy savings with regard to the ongoing operation of a building. Thus, in accordance with sustainable building design, it is extremely important to understand buildings in their entirety and to look at their building facilities in an integral way. This article discusses the energy potentials of building automation and control and how the potentials can be calculated and increased. Further more, it will be presented which tools are needed for an optimized building operation management. (orig.)

  7. Key requirements for future control room functionality

    DEFF Research Database (Denmark)

    Tornelli, Carlo; Zuelli, Roberto; Marinelli, Mattia

    2016-01-01

    This internal report provides the key requirements for the future control centres. R8.1 represents the starting point of WP8 activities and wants to achieve a double objective. On the one hand it collects general requirements on future control centres emerging from the general trends in power...... system operation as well as experiences and results from other European projects. On the other hand, it analyses what requirements for future control rooms arise from the ELECTRA proposed control solutions. Hence, different points of view are taken into account. The ELECTRA Use Cases (UCs...... requirements for the future control centres discussed within this report. The analysis of what happened before the European system disturbance occurred on 4th November 2006 and of the existing trends by vendors helped T8.1 in the definition of the requirements for the future control centres. Volunteer...

  8. OVERVIEW OF A RECONFIGURABLE SIMULATOR FOR MAIN CONTROL ROOM UPGRADES IN NUCLEAR POWER PLANTS

    Energy Technology Data Exchange (ETDEWEB)

    Ronald L. Boring

    2012-10-01

    This paper provides background on a reconfigurable control room simulator for nuclear power plants. The main control rooms in current nuclear power plants feature analog technology that is growing obsolete. The need to upgrade control rooms serves the practical need of maintainability as well as the opportunity to implement newer digital technologies with added functionality. There currently exists no dedicated research simulator for use in human factors design and evaluation activities for nuclear power plant modernization in the U.S. The new research simulator discussed in this paper provides a test bed in which operator performance on new control room concepts can be benchmarked against existing control rooms and in which new technologies can be validated for safety and usability prior to deployment.

  9. 49 CFR 192.631 - Control room management.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Control room management. 192.631 Section 192.631... BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Operations § 192.631 Control room management. (a... operator must have and follow written control room management procedures that implement the requirements...

  10. Psychological and Physical Stress in Surgeons Operating in a Standard or Modern Operating Room

    DEFF Research Database (Denmark)

    Klein, M.; Andersen, L.P.H.; Alamili, M.

    2010-01-01

    concerning physical and psychological wellbeing before and after surgery and had their heart rate variability registered during surgery. Results: Preoperative to postoperative physical strain and pain measurements revealed a systematical difference with 14 of 15 parameters favoring the modern OR. Two...... of these parameters reached statistical significance. We did not find any significant differences in the subjective parameters of surgeon satisfaction or the measured heart rate variability parameters. Conclusions: Physical strain on the surgeon was reduced when performing laparoscopic cholecystectomy in a modern......Purpose: There have been no studies examining the effect of optimized ergonomic and technical environment on the psychological and physiological stress of the surgeon. The aim of this study was to examine whether optimized ergonomics and technical aids within a modern operating room (OR) affect...

  11. Room temperature coherent control of coupled single spins in solid

    CERN Document Server

    Gaebel, T; Popa, I; Wittmann, C; Neumann, P; Jelezko, F; Rabeau, J R; Stavrias, N; Greentree, A D; Prawer, S; Meijer, J; Twamley, J; Hemmer, P R; Wrachtrup, J

    2006-01-01

    Coherent coupling between single quantum objects is at the heart of modern quantum physics. When coupling is strong enough to prevail over decoherence, it can be used for the engineering of correlated quantum states. Especially for solid-state systems, control of quantum correlations has attracted widespread attention because of applications in quantum computing. Such coherent coupling has been demonstrated in a variety of systems at low temperature1, 2. Of all quantum systems, spins are potentially the most important, because they offer very long phase memories, sometimes even at room temperature. Although precise control of spins is well established in conventional magnetic resonance3, 4, existing techniques usually do not allow the readout of single spins because of limited sensitivity. In this paper, we explore dipolar magnetic coupling between two single defects in diamond (nitrogen-vacancy and nitrogen) using optical readout of the single nitrogen-vacancy spin states. Long phase memory combined with a d...

  12. A Pilot Study Investigating the Effects of Advanced Nuclear Power Plant Control Room Technologies: Methods and Qualitative Results

    Energy Technology Data Exchange (ETDEWEB)

    BLanc, Katya Le [Idaho National Lab. (INL), Idaho Falls, ID (United States); Powers, David [Idaho National Lab. (INL), Idaho Falls, ID (United States); Joe, Jeffrey [Idaho National Lab. (INL), Idaho Falls, ID (United States); Spielman, Zachary [Idaho National Lab. (INL), Idaho Falls, ID (United States); Rice, Brandon [Idaho National Lab. (INL), Idaho Falls, ID (United States); Fitzgerald, Kirk [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-08-01

    Control room modernization is an important part of life extension for the existing light water reactor fleet. None of the 99 currently operating commercial nuclear power plants in the U.S. has completed a full-scale control room modernization to date. Nuclear power plant main control rooms for the existing commercial reactor fleet remain significantly analog, with only limited digital modernizations. Upgrades in the U.S. do not achieve the full potential of newer technologies that might otherwise enhance plant and operator performance. The goal of the control room upgrade benefits research is to identify previously overlooked benefits of modernization, identify candidate technologies that may facilitate such benefits, and demonstrate these technologies through human factors research. This report describes a pilot study to test upgrades to the Human Systems Simulation Laboratory at INL.

  13. HYBRID ALARM SYSTEMS: COMBINING SPATIAL ALARMS AND ALARM LISTS FOR OPTIMIZED CONTROL ROOM OPERATION

    Energy Technology Data Exchange (ETDEWEB)

    Ronald L. Boring; J.J. Persensky

    2012-07-01

    The US Department of Energy (DOE) is sponsoring research, development, and deployment on Light Water Reactor Sustainability (LWRS), in which the Idaho National Laboratory (INL) is working closely with nuclear utilities to develop technologies and solutions to help ensure the safe operational life extension of current nuclear power plants. One of the main areas of focus is control room modernization. Within control room modernization, alarm system upgrades present opportunities to meet the broader goals of the LWRS project in demonstrating the use and safety of the advanced instrumentation and control (I&C) technologies and the short-term and longer term objectives of the plant. In this paper, we review approaches for and human factors issues behind upgrading alarms in the main control room of nuclear power plants.

  14. Human reliability analysis of control room operators

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Isaac J.A.L.; Carvalho, Paulo Victor R.; Grecco, Claudio H.S. [Instituto de Engenharia Nuclear (IEN), Rio de Janeiro, RJ (Brazil)

    2005-07-01

    Human reliability is the probability that a person correctly performs some system required action in a required time period and performs no extraneous action that can degrade the system Human reliability analysis (HRA) is the analysis, prediction and evaluation of work-oriented human performance using some indices as human error likelihood and probability of task accomplishment. Significant progress has been made in the HRA field during the last years, mainly in nuclear area. Some first-generation HRA methods were developed, as THERP (Technique for human error rate prediction). Now, an array of called second-generation methods are emerging as alternatives, for instance ATHEANA (A Technique for human event analysis). The ergonomics approach has as tool the ergonomic work analysis. It focus on the study of operator's activities in physical and mental form, considering at the same time the observed characteristics of operator and the elements of the work environment as they are presented to and perceived by the operators. The aim of this paper is to propose a methodology to analyze the human reliability of the operators of industrial plant control room, using a framework that includes the approach used by ATHEANA, THERP and the work ergonomics analysis. (author)

  15. Harvest control rules in modern fisheries management

    Directory of Open Access Journals (Sweden)

    Sturla F. Kvamsdal

    2016-07-01

    Full Text Available Abstract Harvest control rules have become an important tool in modern fisheries management, and are increasingly adopted to provide continuity in management practices, to deal with uncertainty and ecosystem considerations, and to relieve management decisions from short-term political pressure. We provide the conceptual and institutional background for harvest control rules, a discussion of the structure of fisheries management, and brief introductions to harvest control rules in a selection of present day cases. The cases demonstrate that harvest control rules take different forms in different settings, yet cover only a subset of the full policy space. We conclude with views on harvest control rules in future fisheries management, both in terms of ideal and realistic developments. One major challenge for future fisheries management is closing the gap between ideas and practice.

  16. Testing Efficiency Improved by Addition of Remote Access Control Room

    Science.gov (United States)

    1996-01-01

    The NASA Lewis Research Center's Remote Access Control Room (RACR) uses off-the-shelf video conferencing software integrated with existing facility data systems to provide access to the test data by networking from virtually anywhere in the country. The system allows research engineers in remote locations to participate in tests and monitor data in real time just as if they were present in the control room.

  17. Bridging the gap: adapting advanced display technologies for use in hybrid control rooms

    Energy Technology Data Exchange (ETDEWEB)

    Jokstad, Håkon [Inst. for Energy Technology, Halden (Norway); Boring, Ronald [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-02-01

    The Institute for Energy Technology (IFE), runs the OECD Halden Reactor Project (HRP), featuring a state-of-the-art research simulator facility in Halden, Norway, called HAMMLAB. HAMMLAB serves two main purposes: the study of human behaviour in interaction with complex process systems; and the development, test and evaluation of prototype control centres and their individual systems. By studying operator performance in HAMMLAB and integrating the knowledge gained into new designs, the HRP contributes to improving operational safety, reliability, efficiency and productivity. The U.S. Department of Energy’s (DOE) Light Water Reactor Sustainability (LWRS) Program has contracted IFE to assist DOE national laboratory staff at Idaho National Laboratory (INL) in adapting HAMMLAB design concepts for the purpose of control room modernization at nuclear power plants in the U.S. In support of this effort, the DOE has built a simulator research facility at INL called the Human Systems Simulation Laboratory (HSSL). The HSSL is centered on control room modernization, in which industry provided plant instrumentation and controls are modified for upgrade opportunities. The HSSL houses the LWRS simulator, which is a reconfigurable full-scale and full-scope control room simulator. Consisting of 45 large touchscreens on 15 panels, the LWRS simulator is currently using this glass top technology to digitally represent and replicate the functionality of the analog I&C systems in existing control rooms. The LWRS simulator is reconfigurable in that different plant training simulator models obtained from the utilities can be run on the panels, and the panels can be physically moved and arranged to mimic the layout of those control rooms. The glass top technology and reconfigurability capabilities allow the LWRS simulator to be the research platform that is necessary to design, prototype, and validate human-system interface (HSI) technologies that can replace existing analog I&C. IFE has

  18. Control of the Environment in the Operating Room.

    Science.gov (United States)

    Katz, Jonathan D

    2016-09-23

    There is a direct relationship between the quality of the environment of a workplace and the productivity and efficiency of the work accomplished. Components such as temperature, humidity, ventilation, drafts, lighting, and noise each contribute to the quality of the overall environment and the sense of well-being of those who work there.The modern operating room is a unique workplace with specific, and frequently conflicting, environmental requirements for each of the inhabitants. Even minor disturbances in the internal environment of the operating room can have serious ramifications on the comfort, effectiveness, and safety of each of the inhabitants. A cool, well-ventilated, and dry climate is optimal for many members of the surgical team. Any significant deviation from these objectives raises the risk of decreased efficiency and productivity and adverse surgical outcomes. A warmer, more humid, and quieter environment is necessary for the patient. If these requirements are not met, the risk of surgical morbidity and mortality is increased. An important task for the surgical team is to find the correct balance between these 2 opposed requirements. Several of the components of the operating room environment, especially room temperature and airflow patterns, are easily manipulated by the members of the surgical team. In the following discussion, we will examine these elements to better understand the clinical ramifications of adjustments and accommodations that are frequently made to meet the requirements of both the surgical staff and the patient.

  19. Migration of Older to New Digital Control Systems in Nuclear Power Plant Main Control Rooms

    Energy Technology Data Exchange (ETDEWEB)

    Kovesdi, Casey Robert [Idaho National Lab. (INL), Idaho Falls, ID (United States); Joe, Jeffrey Clark [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-04-01

    The United States (U.S.) Department of Energy (DOE) Office of Nuclear Energy (NE) has the primary mission to advance nuclear power by resolving socio-technical issues through research and development (R&D). One DOE-NE activity supporting this mission is the Light Water Reactor Sustainability (LWRS) program. LWRS has the overall objective to sustain the operation of existing commercial nuclear power plants (NPPs) through conducting R&D across multiple “pathways,” or R&D focus areas. The Advanced Instrumentation, Information, and Control (II&C) Systems Technologies pathway conducts targeted R&D to address aging and reliability concerns with the legacy instrumentation and control (I&C) and related information systems in operating U.S. NPPs. This work involves (1) ensuring that legacy analog II&C systems are not life-limiting issues for the LWR fleet, and (2) implementing digital II&C technology in a manner that enables broad innovation and business improvement in the NPP operating model. Under the LWRS Advanced II&C pathway, Human Factors experts at Idaho National Laboratory (INL) have been conducting R&D in support of NPP main control room (MCR) modernization activities. Work in prior years has focused on migrating analog I&C systems to new digital I&C systems (). In fiscal year 2016 (FY16), one new focus area for this research is migrating older digital I&C systems to new and advanced digital I&C systems. This report summarizes a plan for conducting a digital-to-digital migration of a legacy digital I&C system to a new digital I&C system in support of control room modernization activities.

  20. 49 CFR 195.446 - Control room management.

    Science.gov (United States)

    2010-10-01

    ... system must have a written alarm management plan to provide for effective controller response to alarms...; (iv) Procedures; (v) SCADA system configuration; and (vi) SCADA system performance. (2) Include... 49 Transportation 3 2010-10-01 2010-10-01 false Control room management. 195.446 Section 195.446...

  1. Team of the Technical Control Room, TCR, at work

    CERN Multimedia

    Maximilien Brice

    2002-01-01

    0202037_06 transmit of the instruction from a team TCR to the changing .0202037_01 Kenneth Olesen brings a solution to a user of the CERN, while Mark Harvey checks its monitors .0202037_02 Laurent Randot and Eric Lienard (with the phone) work in the control room .0202037_08 Mr Jean-Pierre Hernández, shift leader TCR , stay near the order console for the electric wire of the CERN .0202037_09 The order console with all the diode on .0202037_10 View of the control room .

  2. Modern control of mineral wool production process

    Directory of Open Access Journals (Sweden)

    Stankov Stanko P.

    2013-01-01

    Full Text Available In this paper, the control of the plant for mineral wool production consisting of a number of the technological units of different sizes and complexity is considered. The application of modern equipment based on PLC (Programmable Logic Controller and SCADA (Supervisory Control And Data Acquisition configuration provides optimal control of technological process. Described supervisory and control system is consisting of a number of units doing decentralized distributed control of technological entities where all possible situation are considered during work of machines and devices, which are installed in electric drive and are protected from technological and electrical accident. Transformer station and diesel engine, raw materials transport and dosage, processes in dome oven, centrifuges, polycondensation (PC chamber, burners, compressor station, binder preparation and dosage, wool cutting, completed panel packing and their transport to storehouse are controlled. Process variables and parameters like as level, flow, velocity, temperature, pressure, etc. are controlled. Control system is doing identification of process states changes, diagnostic and prediction of errors and provides prediction of behavior of control objects when input flows of materials and generates optimal values of control variables due to decreasing downtime and technic - economical requires connected to wool quality to be achieved. Supervisory and control system either eliminates unwanted changes in the production line or restricts them within the allowable limits according to the technology. In this way, the optimization of energy and raw materials consumption and appropriate products quality is achieved, where requirements are satisfied in accordance with process safety and environmental standards. SCADA provides a visual representation of controlled and uncontrolled parts of the technological process, processing alarms and events, monitoring of the changes of relevant

  3. Thinking in three's: Changing surgical patient safety practices in the complex modern operating room

    Institute of Scientific and Technical Information of China (English)

    Verna C Gibbs

    2012-01-01

    The three surgical patient safety events,wrong site surgery,retained surgical items (RSI) and surgical fires are rare occurrences and thus their effects on the complex modern operating room (OR) are difficult to study.The likelihood of occurrence and the magnitude of risk for each of these surgical safety events are undefined.Many providers may never have a personal experience with one of these events and training and education on these topics are sparse.These circumstances lead to faulty thinking that a provider won't ever have an event or if one does occur the provider will intuitively know what to do.Surgeons are not preoccupied with failure and tend to usually consider good outcomes,which leads them to ignore or diminish the importance of implementing and following simple safety practices.These circumstances contribute to the persistent low level occurrence of these three events and to the difficulty in generating sufficient interest to resource solutions.Individual facilities rarely have the time or talent to understand these events and develop lasting solutions.More often than not,even the most well meaning internal review results in a new line to a policy and some rigorous enforcement mandate.This approach routinely fails and is another reason why these problems are so persistent.Vigilance actions alone have been unsuccessful so hospitals now have to take a systematic approach to implementing safer processes and providing the resources for surgeons and other stakeholders to optimize the OR environment.This article discusses standardized processes of care for mitigation of injury or outright prevention of wrong site surgery,RSI and surgical fires in an action-oriented framework illustrating the strategic elements important in each event and focusing on the responsibilities for each of the three major OR agents-anesthesiologists,surgeons and nurses.A Surgical Patient Safety Checklist is discussed that incorporates the necessary elements to bring these team

  4. MSFC Director James R. Thompson in Control Room

    Science.gov (United States)

    1988-01-01

    Marshall's fifth Center Director, James R. Thompson (1986-1989), in the control room of the Solid Rocket Booster (SRB)automated thermal protection system (TPS) removal facility. Under Dr. Thompson's leadership, the shuttle program was rekindled after the Challenger explosion. Return to Flight kept NASA 's future programs alive.

  5. Computer codes for evaluation of control room habitability (HABIT)

    Energy Technology Data Exchange (ETDEWEB)

    Stage, S.A. [Pacific Northwest Lab., Richland, WA (United States)

    1996-06-01

    This report describes the Computer Codes for Evaluation of Control Room Habitability (HABIT). HABIT is a package of computer codes designed to be used for the evaluation of control room habitability in the event of an accidental release of toxic chemicals or radioactive materials. Given information about the design of a nuclear power plant, a scenario for the release of toxic chemicals or radionuclides, and information about the air flows and protection systems of the control room, HABIT can be used to estimate the chemical exposure or radiological dose to control room personnel. HABIT is an integrated package of several programs that previously needed to be run separately and required considerable user intervention. This report discusses the theoretical basis and physical assumptions made by each of the modules in HABIT and gives detailed information about the data entry windows. Sample runs are given for each of the modules. A brief section of programming notes is included. A set of computer disks will accompany this report if the report is ordered from the Energy Science and Technology Software Center. The disks contain the files needed to run HABIT on a personal computer running DOS. Source codes for the various HABIT routines are on the disks. Also included are input and output files for three demonstration runs.

  6. Information Foraging in Nuclear Power Plant Control Rooms

    Energy Technology Data Exchange (ETDEWEB)

    R.L. Boring

    2011-09-01

    nformation foraging theory articulates the role of the human as an 'informavore' that seeks information and follows optimal foraging strategies (i.e., the 'information scent') to find meaningful information. This paper briefly reviews the findings from information foraging theory outside the nuclear domain and then discusses the types of information foraging strategies operators employ for normal and off-normal operations in the control room. For example, operators may employ a predatory 'wolf' strategy of hunting for information in the face of a plant upset. However, during routine operations, the operators may employ a trapping 'spider' strategy of waiting for relevant indicators to appear. This delineation corresponds to information pull and push strategies, respectively. No studies have been conducted to determine explicitly the characteristics of a control room interface that is optimized for both push and pull information foraging strategies, nor has there been empirical work to validate operator performance when transitioning between push and pull strategies. This paper explores examples of control room operators as wolves vs. spiders and con- cludes by proposing a set of research questions to investigate information foraging in control room settings.

  7. Inside the LEP control room at start-up

    CERN Multimedia

    1989-01-01

    Physicists grouped around a screen in the LEP control room at the strat-up of LEP on 14 July 1989. The emotion of the moment is clear. Carlo Rubbia, Director-General of CERN at the time, is in the centre and on his left, Herwig Schopper, former Director-General of the Organization.

  8. An Electronic Logbook for the HEP Control Room

    Institute of Scientific and Technical Information of China (English)

    G.Roediger; P.Pomatto; 等

    2001-01-01

    The Control Room Logbook(CRL)is designed to improve and replace the paper logbooks traditionally used in the HEP accelerator control room.Its features benefit the on-line coordinator,the shift operators,and the remote observers,This paper explains some of the most attractive features for each of these roles.The features include the ability to configure the logbook for the specific needs of a collaboration,a large variety of entry types operator can add by simply clicking and dragging,and a flexible web interface for the remote observer to keep up with control room activities.The entries are saved as UTF-8 based XML files,which allowed us to give the data structure and meaning such that it can easily be parsed in the present and far into the future.The XML tag data is also indexed in a relational database,making queries on dates,keyworks,entry type and other criteria feasible and fast .The CRL is used in the D0 control room.This presentation also discusses our experience with deployment,platform independence and other interesting issues that arose with the installation and use of logbook.

  9. Control room envelope unfiltered air inleakage test protocols

    Energy Technology Data Exchange (ETDEWEB)

    Lagus, P.L. [Lagus Applied Technology, San Diego, CA (United States); Grot, R.A. [Lagus Applied Technology, Olney, MD (United States)

    1997-08-01

    In 1983, the Advisory Committee on Reactor Safeguards (ACRS) recommended that the US NRC develop a control room HVAC performance testing protocol. To date no such protocol has been forthcoming. Beginning in mid-1994, an effort was funded by NRC under a Small Business Innovation Research (SBIR) grant to develop several simplified test protocols based on the principles of tracer gas testing in order to measure the total unfiltered inleakage entering a CRE during emergency mode operation of the control room ventilation system. These would allow accurate assessment of unfiltered air inleakage as required in SRP 6.4. The continuing lack of a standard protocol is unfortunate since one of the significant parameters required to calculate operator dose is the amount of unfiltered air inleakage into the control room. Often it is assumed that, if the Control Room Envelope (CRE) is maintained at +1/8 in. w.g. differential pressure relative to the surroundings, no significant unfiltered inleakage can occur it is further assumed that inleakage due to door openings is the only source of unfiltered air. 23 refs., 13 figs., 2 tabs.

  10. Controlling allergens in animal rooms by using curtains

    DEFF Research Database (Denmark)

    Krohn, Thomas Cæcius; Itter, Gabi; Fosse, Richard

    2006-01-01

    . The experimental situation we studied provides some information regarding allergen disposition in animal rooms but is clearly artificial and does not reflect a typical, ‘real-world’ environment in terms of preventing exposure of workers to allergens. Plastic curtains with holes were placed in front of racks......The reduction and control of allergens in the animal facility is important for staff working with laboratory animals. This study was designed to evaluate the efficiency of perforated Makrolon curtains in front of racks as a method to reduce the amount of allergen in the animal room...... the curtains and prevents its spread from the cages into the aisle. The present study shows that the use of curtains in front of the cage racks is an efficient way to prevent spread of allergens from rodent cages to the entire animal room....

  11. Look into the PS Main Control Room (partial view)

    CERN Multimedia

    1974-01-01

    Jean-Pierre Potier at work. The 26 GeV Synchrotron and later also its related machines (Linacs 1,2,3; PS-Booster, LEP-Injector Linacs and Electron-Positron Accumulator; Antiproton Accumulator, Antiproton Collector, Low Energy Antiproton Ring and more recently Antiproton Decelerator) were all controlled from the PS control room situated at the Meyrin site. The SPS and LEP were controlled from a separat control centre on the Prevessin site. In 2005 all controls were transferred to the Prevessin centre.

  12. Feasibility of touch-less control of operating room lights.

    Science.gov (United States)

    Hartmann, Florian; Schlaefer, Alexander

    2013-03-01

    Today's highly technical operating rooms lead to fairly complex surgical workflows where the surgeon has to interact with a number of devices, including the operating room light. Hence, ideally, the surgeon could direct the light without major disruption of his work. We studied whether a gesture tracking-based control of an automated operating room light is feasible. So far, there has been little research on control approaches for operating lights. We have implemented an exemplary setup to mimic an automated light controlled by a gesture tracking system. The setup includes a articulated arm to position the light source and an off-the-shelf RGBD camera to detect the user interaction. We assessed the tracking performance using a robot-mounted hand phantom and ran a number of tests with 18 volunteers to evaluate the potential of touch-less light control. All test persons were comfortable with using the gesture-based system and quickly learned how to move a light spot on flat surface. The hand tracking error is direction-dependent and in the range of several centimeters, with a standard deviation of less than 1 mm and up to 3.5 mm orthogonal and parallel to the finger orientation, respectively. However, the subjects had no problems following even more complex paths with a width of less than 10 cm. The average speed was 0.15 m/s, and even initially slow subjects improved over time. Gestures to initiate control can be performed in approximately 2 s. Two-thirds of the subjects considered gesture control to be simple, and a majority considered it to be rather efficient. Implementation of an automated operating room light and touch-less control using an RGBD camera for gesture tracking is feasible. The remaining tracking error does not affect smooth control, and the use of the system is intuitive even for inexperienced users.

  13. Control of Computer Room Air Conditioning using IT Equipment Sensors

    Energy Technology Data Exchange (ETDEWEB)

    Bell, Geoffrey C.; Storey, Bill; Patterson, Michael K.

    2009-09-30

    The goal of this demonstration was to show how sensors in IT equipment could be accessed and used to directly control computer room air conditioning. The data provided from the sensors is available on the IT network and the challenge for this project was to connect this information to the computer room air handler's control system. A control strategy was developed to enable separate control of the chilled water flow and the fans in the computer room air handlers. By using these existing sensors in the IT equipment, an additional control system is eliminated (or could be redundant) and optimal cooling can be provided saving significant energy. Using onboard server temperature sensors will yield significant energy reductions in data centers. Intel hosted the demonstration in its Santa Clara, CA data center. Intel collaborated with IBM, HP, Emerson, Wunderlich-Malec Engineers, FieldServer Technologies, and LBNL to install the necessary components and develop the new control scheme. LBNL also validated the results of the demonstration.

  14. Report for Task 8.4: Development of Control Room Layout Recommendations

    Energy Technology Data Exchange (ETDEWEB)

    McDonald, Robert [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-09-01

    Idaho National Laboratory (INL) has contracted Institutt for Energiteknikk (IFE) to support in the development of an end state vision for the US Nuclear industry and in particular for a utility that is currently moving forward with a control room modernization project. This support includes the development of an Overview display and technical support in conducting an operational study. Development of operational scenarios to be conducted using a full scope simulator at the INL HSSL. Additionally IFE will use the CREATE modelling tool to provide 3-D views of the potential and possible end state view after the completion of digital upgrade project.

  15. Virtual Visit to the ATLAS Control Room by leading universities of Russian Federation

    CERN Multimedia

    ATLAS Experiment

    2012-01-01

    Science Festival in Russian Federation is a programme of events which take place at the leading scientific centres and museums in Russia. At the Science Festival scientists, engineers and students show to visitors the advances of modern science and technology in all scopes of life. Today the leading universities of Russia will feature a multipoint video conference with the LHC control room at CERN. This will give visitors of the Science Festival the opportunity to ask questions to the physicists involved about the Large Hadron Collider experiments, Higgs particles and antimatter. http://atlas-live-virtual-visit.web.cern.ch/atlas-live-virtual-visit/2012/Russia-2012.html

  16. CERN opens up its control rooms to youngsters

    CERN Multimedia

    CERN Bulletin

    2011-01-01

    CERN is inviting 13 to 18 year-olds to come and spend a couple of hours in the control rooms of the LHC and its experiments. Registration is now open.   Is your neighbour's kid eager to come and see what's going on in the CERN control rooms for himself? Is your niece from Germany fascinated by the famous accelerator near Geneva that she's heard about and asking to know more? Then Researchers Night is for them! From 6.00 p.m. on Friday 23 September until 1.00 a.m. the following morning, the LHC and its experiments will open their doors to 13 to 18 year-olds. They are invited to come and spend a couple of hours in the control rooms watching the physicists and taking part in various activities. ALICE, ATLAS, CMS, LHCb, TOTEM, and the CERN Control Centre (CCC) will all be welcoming visitors. For this second year of CERN's involvement in European Researchers Night, the CERN exhibitions will be open late and special activities will be organised in Microcosm....

  17. Advanced control room evaluation: General approach and rationale

    Energy Technology Data Exchange (ETDEWEB)

    O' Hara, J.M. (Brookhaven National Lab., Upton, NY (USA)); Wachtel, J. (Nuclear Regulatory Commission, Washington, DC (USA))

    1991-01-01

    Advanced control rooms (ACRs) for future nuclear power plants (NPPs) are being designed utilizing computer-based technologies. The US Nuclear Regulatory Commission reviews the human engineering aspects of such control rooms to ensure that they are designed to good human factors engineering principles and that operator performance and reliability are appropriately supported in order to protect public health and safety. This paper describes the rationale and general approach to the development of a human factors review guideline for ACRs. The factors influencing the guideline development are discussed, including the review environment, the types of advanced technologies being addressed, the human factors issues associated with advanced technology, and the current state-of-the-art of human factors guidelines for advanced human-system interfaces (HSIs). The proposed approach to ACR review would track the design and implementation process through the application of review guidelines reflecting four review modules: planning, design process analysis, human factors engineering review, and dynamic performance evaluation. 21 refs.

  18. Response Times of Operators in a Control Room

    DEFF Research Database (Denmark)

    Platz, O.; Rasmussen, J.; Skanborg, Preben Zacho

    A statistical analysis was made of operator response times recorded in the control room of a research reactor during the years 1972-1974. A homogeneity test revealed that the data consist of a mixture of populations. A small but statistically significant difference is found between day and night ...... response times. Lognormal distributions are found to provide the best fit of the day and the night response times....

  19. The Prevessin Control Room during LEP's start up in 1989.

    CERN Multimedia

    1989-01-01

    The Prévessin Control Room saw its first momentous event when the 400 GeV beam for the SPS was commissioned in the presence of Project Leader John Adams. It was also here that the first proton-antiproton collisions were observed, in 1981. Eight years later, in 1989, operators and directors alike jumped for joy at the announcement of the first electron-positron collisions at the start up of LEP, the biggest accelerator in the world.

  20. Remote control of magnetostriction-based nanocontacts at room temperature.

    Science.gov (United States)

    Jammalamadaka, S Narayana; Kuntz, Sebastian; Berg, Oliver; Kittler, Wolfram; Kannan, U Mohanan; Chelvane, J Arout; Sürgers, Christoph

    2015-09-01

    The remote control of the electrical conductance through nanosized junctions at room temperature will play an important role in future nano-electromechanical systems and electronic devices. This can be achieved by exploiting the magnetostriction effects of ferromagnetic materials. Here we report on the electrical conductance of magnetic nanocontacts obtained from wires of the giant magnetostrictive compound Tb0.3Dy0.7Fe1.95 as an active element in a mechanically controlled break-junction device. The nanocontacts are reproducibly switched at room temperature between "open" (zero conductance) and "closed" (nonzero conductance) states by variation of a magnetic field applied perpendicularly to the long wire axis. Conductance measurements in a magnetic field oriented parallel to the long wire axis exhibit a different behaviour where the conductance switches between both states only in a limited field range close to the coercive field. Investigating the conductance in the regime of electron tunneling by mechanical or magnetostrictive control of the electrode separation enables an estimation of the magnetostriction. The present results pave the way to utilize the material in devices based on nano-electromechanical systems operating at room temperature.

  1. Virtual Visit to the ATLAS Control Room by Greek Physical Society Annual Student Meeting

    CERN Multimedia

    2013-01-01

    In a continuation of last years` efforts, The Hellenic Union of Physicists organises for the 5th consecutive year its annual meeting for high-performing students across Greece. In this creative thinking meeting, students will have an excellent opportunity to acquire an in-depth understanding in contemporary physics issues and topics as well as in modern scientific knowledge and thinking in general. Moreover, they will be introduced to modern scientific methods and will practice critical thinking via live interaction with distinctive physicists. During this meeting, students will also connect live to the ATLAS control room to talk to a Greek physicist and learn about latest developments from the world`s largest physics laboratory.

  2. Low frequency sound field control for loudspeakers in rectangular rooms using CABS (Controlled Acoustical Bass System)

    DEFF Research Database (Denmark)

    Nielsen, Sofus Birkedal; Celestinos, Adrian

    2010-01-01

    Rectangular rooms are the most common shape for sound reproduction, but at low frequencies the reflections from the boundaries of the room cause large spatial variations in the sound pressure level.  Variations up to 30 dB are normal, not only at the room modes, but basically at all frequencies....... As sound propagates in time, it seems natural that the problems can best be analyzed and solved in the time domain. A time based room correction system named CABS (Controlled Acoustical Bass System) has been developed for sound reproduction in rectangular listening rooms. It can control the sound...... distribution in the room at low frequencies by using multiple loudspeakers together with an optimal placement of the loudspeakers.  At low frequencies CABS will create a plane wave from the front wall loudspeakers which will be absorbed by additional loudspeakers at the rear wall giving an almost homogeneous...

  3. Elements of Clean-room Technology and Contamination Control

    Directory of Open Access Journals (Sweden)

    J.C. Kapoor

    2003-07-01

    Full Text Available The heart of the clean room is the high efticiency particualte air (HEPA/ultra-low penetration air (ULPA filter, which provides the highest level of air cleaning ever achieved by a singleprocess step. Filter technology has seen tremendous growth in terms of ultimate performance and air handling capacity. Mere installation of ULPA filters of 99.99995 per cent efficiency for 0.2 um aerosol is not sufficient for achieving the desired performance of a clean room. Other design aspects like flow fields, face velocity, number of air changes, make-up air fractions and precise control of other environmental parameters (temperature, humidity, airflow, noise, vibrations, electrostatic discharge, etc. are equally important.

  4. Simon van der Meer in the AA Control Room

    CERN Multimedia

    CERN PhotoLab

    1984-01-01

    Simon van der Meer, spiritus rector of the Antiproton Accumulator, in the AA Control Room. Inventor of stochastic cooling, on which the AA was based, and of the magnetic horn, with which the antiprotons were focused, he also wrote most of the software with which the AA was controlled, and spent uncountable numbers of hours in this chair to tickle the AA to top performance. 8 months after this picture was taken, he received, in October 1984, the Nobel prize, together with Carlo Rubbia, the moving force behind the whole Proton-Antiproton Collider project that led to the discovery, in 1983, of the W and Z intermediate bosons.

  5. FRAMEWORK AND APPLICATION FOR MODELING CONTROL ROOM CREW PERFORMANCE AT NUCLEAR POWER PLANTS

    Energy Technology Data Exchange (ETDEWEB)

    Ronald L Boring; David I Gertman; Tuan Q Tran; Brian F Gore

    2008-09-01

    This paper summarizes an emerging project regarding the utilization of high-fidelity MIDAS simulations for visualizing and modeling control room crew performance at nuclear power plants. The key envisioned uses for MIDAS-based control room simulations are: (i) the estimation of human error associated with advanced control room equipment and configurations, (ii) the investigative determination of contributory cognitive factors for risk significant scenarios involving control room operating crews, and (iii) the certification of reduced staffing levels in advanced control rooms. It is proposed that MIDAS serves as a key component for the effective modeling of cognition, elements of situation awareness, and risk associated with human performance in next generation control rooms.

  6. Low frequency sound field control for loudspeakers in rectangular rooms using CABS (Controlled Acoustical Bass System)

    DEFF Research Database (Denmark)

    Nielsen, Sofus Birkedal; Celestinos, Adrian

    2010-01-01

    . As sound propagates in time, it seems natural that the problems can best be analyzed and solved in the time domain. A time based room correction system named CABS (Controlled Acoustical Bass System) has been developed for sound reproduction in rectangular listening rooms. It can control the sound...... distribution in the room at low frequencies by using multiple loudspeakers together with an optimal placement of the loudspeakers.  At low frequencies CABS will create a plane wave from the front wall loudspeakers which will be absorbed by additional loudspeakers at the rear wall giving an almost homogeneous...... sound field in the whole room, and short impulse response.  In a standard listening room (180 m3) only 4 loudspeakers are needed, 2 more than a traditional stereo setup. CABS is controlled by a developed DSP system. The time based approached might help with the understanding of sound field control...

  7. Digital Full-Scope Simulation of a Conventional Nuclear Power Plant Control Room, Phase 2: Installation of a Reconfigurable Simulator to Support Nuclear Plant Sustainability

    Energy Technology Data Exchange (ETDEWEB)

    Ronald L. Boring; Vivek Agarwal; Kirk Fitzgerald; Jacques Hugo; Bruce Hallbert

    2013-03-01

    The U.S. Department of Energy’s Light Water Reactor Sustainability program has developed a control room simulator in support of control room modernization at nuclear power plants in the U.S. This report highlights the recent completion of this reconfigurable, full-scale, full-scope control room simulator buildout at the Idaho National Laboratory. The simulator is fully reconfigurable, meaning it supports multiple plant models developed by different simulator vendors. The simulator is full-scale, using glasstop virtual panels to display the analog control boards found at current plants. The present installation features 15 glasstop panels, uniquely achieving a complete control room representation. The simulator is also full-scope, meaning it uses the same plant models used for training simulators at actual plants. Unlike in the plant training simulators, the deployment on glasstop panels allows a high degree of customization of the panels, allowing the simulator to be used for research on the design of new digital control systems for control room modernization. This report includes separate sections discussing the glasstop panels, their layout to mimic control rooms at actual plants, technical details on creating a multi-plant and multi-vendor reconfigurable simulator, and current efforts to support control room modernization at U.S. utilities. The glasstop simulator provides an ideal testbed for prototyping and validating new control room concepts. Equally importantly, it is helping create a standardized and vetted human factors engineering process that can be used across the nuclear industry to ensure control room upgrades maintain and even improve current reliability and safety.

  8. Capturing Control Room Simulator Data with the HERA Database

    Energy Technology Data Exchange (ETDEWEB)

    Ronald Boring; April Whaley; Bruce Hallbert; Karin Laumann; Per Oivind Braarud; Andreas Bye; Erasmia Lois; Yung Hsien James Chang

    2007-08-01

    The Human Event Repository and Analysis (HERA) system has been developed as a tool for classifying and recording human performance data extracted from primary data sources. This paper reviews the process of extracting data from simulator studies for use in HERA. Simulator studies pose unique data collection challenges, both in types and quality of data measures, but such studies are ideally suited to gather operator performance data, including the full spectrum of performance shaping factors used in a HERA analysis. This paper provides suggestions for obtaining relevant human performance data for a HERA analysis from a control room simulator study and for inputting those data in a format suitable for HERA.

  9. CERN's Technical Control Room (TCR) A Central Service for Everyone

    CERN Multimedia

    Mario Batz

    2001-01-01

    The Technical Control Room (TCR) monitors and operates the entire technical infrastructure of CERN 24 hours a day, 365 days a year. It registers and dispatches troubleshooting requests to the appropriate equipment services. In addition, the TCR executes first-line interventions on the entire CERN site. Troubleshooting requests are transmitted to the TCR either via a computerised control system or via the phone number '72201'. More than 10'000 such requests are dispatched and dealt with every year. The TCR's diverse field of activity concerns the following systems: electrical and fluid distribution networks, heating, cooling, ventilation, air-conditioning and gas equipment, safety and communication installations, electromechanical systems (e.g. lifts, cranes, machine tools, motorised doors), sanitary systems (leaks, sewage), control and monitoring infrastructure equipment, buildings. These systems can either be part of the administrative infrastructure, such as offices or restaurants, or part of the t...

  10. CERN'S TECHNICAL CONTROL ROOM (TCR) A CENTRAL SERVICE FOR EVERYONE

    CERN Multimedia

    Mario Batz / TCR Responsible

    2000-01-01

    The Technical Control Room (TCR) monitors and operates the entire technical infrastructure of CERN 24 hours a day, 365 days a year. It registers and dispatches troubleshooting requests to the appropriate equipment services. In addition, the TCR executes first-line interventions on the entire CERN site. Troubleshooting requests are transmitted to the TCR either via a computerised control system or via the phone number 72201. More than 10'000 such requests are dispatched and dealt with every year. The TCR's diverse field of activity concerns the following systems: electrical and fluid distribution networks, heating, cooling, ventilation, air-conditioning and gas equipment, safety and communication installations, electromechanical systems (e.g. lifts, cranes, machine tools, motorised doors), sanitary systems (leaks, sewage), control and monitoring infrastructure equipment, buildings. These systems can either be part of the administrative infrastructure, such as offices or restaurants, or part of the tec...

  11. CERN'S TECHNICAL CONTROL ROOM (TCR) A CENTRAL SERVICE FOR EVERYONE

    CERN Multimedia

    Mario Batz (TCR Responsible)

    2001-01-01

    The Technical Control Room (TCR) monitors and operates the entire technical infrastructure of CERN 24 hours a day, 365 days a year. It registers and dispatches troubleshooting requests to the appropriate equipment services. In addition, the TCR executes first-line interventions on the entire CERN site. Troubleshooting requests are transmitted to the TCR either via a computerised control system or via the phone number 72201. More than 10'000 such requests are dispatched and dealt with every year. The TCR's diverse field of activity concerns the following systems: electrical and fluid distribution networks, heating, cooling, ventilation, air-conditioning and gas equipment, safety and communication installations, electromechanical systems (e.g. lifts, cranes, machine tools, motorised doors), sanitary systems (leaks, sewage), control and monitoring infrastructure equipment, buildings. These systems can either be part of the administrative infrastructure, such as offices or restaurants, or part of the tec...

  12. CERN'S TECHNICAL CONTROL ROOM (TCR) A CENTRAL SERVICE FOR EVERYONE

    CERN Multimedia

    Mario Batz (TCR Responsible)

    2001-01-01

    The Technical Control Room (TCR) monitors and operates the entire technical infrastructure of CERN 24 hours a day, 365 days a year. It registers and dispatches troubleshooting requests to the appropriate equipment services. In addition, the TCR executes first-line interventions on the entire CERN site. Troubleshooting requests are transmitted to the TCR either via a computerised control system or via the phone number '72201'. More than 10'000 such requests are dispatched and dealt with every year. The TCR's diverse field of activity concerns the following systems: electrical and fluid distribution networks, heating, cooling, ventilation, air-conditioning and gas equipment, safety and communication installations, electromechanical systems (e.g. lifts, cranes, machine tools, motorised doors), sanitary systems (leaks, sewage), control and monitoring infrastructure equipment, buildings. These systems can either be part of the administrative infrastructure, such as offices or restaurants, or part of the t...

  13. CERN'S TECHNICAL CONTROL ROOM (TCR) A CENTRAL SERVICE FOR EVERYONE

    CERN Multimedia

    Mario Batz

    2002-01-01

    The Technical Control Room (TCR) monitors and operates the entire technical infrastructure of CERN 24 hours a day, 365 days a year. It registers and dispatches troubleshooting requests to the appropriate CERN equipment services or contractors. In addition, the TCR executes first-line interventions on the entire CERN site. Troubleshooting requests are transmitted to the TCR either via a computerised control system or via the phone number '72201'. More than 10'000 such requests are dispatched and dealt with every year. The TCR's diverse field of activity covers the following systems: electrical and fluid distribution networks, heating, cooling, ventilation, air-conditioning and gas equipment, safety and communication installations, electromechanical systems (e.g. lifts, cranes, machine tools, motorised doors), sanitary systems (leaks, sewage), control and monitoring infrastructure equipment, and buildings. These systems can either be part of the administrative infrastructure, such as offices or restaur...

  14. CERN'S TECHNICAL CONTROL ROOM (TCR) A CENTRAL SERVICE FOR EVERYONE

    CERN Multimedia

    Mario Batz

    2002-01-01

    The Technical Control Room (TCR) monitors and operates the entire technical infrastructure of CERN 24 hours a day, 365 days a year. It registers and dispatches troubleshooting requests to the appropriate equipment services. In addition, the TCR executes first-line interventions on the entire CERN site. Troubleshooting requests are transmitted to the TCR either via a computerised control system or via the phone number '72201'. More than 10'000 such requests are dispatched and dealt with every year. The TCR's diverse field of activity concerns the following systems: electrical and fluid distribution networks, heating, cooling, ventilation, air-conditioning and gas equipment, safety and communication installations, electromechanical systems (e.g. lifts, cranes, machine tools, motorised doors), sanitary systems (leaks, sewage), control and monitoring infrastructure equipment, buildings. These systems can either be part of the administrative infrastructure, such as offices or restaurants, or part of the t...

  15. CERN'S TECHNICAL CONTROL ROOM (TCR) A CENTRALSERVICE FOR EVERYONE

    CERN Multimedia

    Mario Batz / TCR Responsible

    2001-01-01

    The Technical Control Room (TCR) monitors and operates the entire technical infrastructure of CERN 24 hours a day, 365 days a year. It registers and dispatches troubleshooting requests to the appropriate equipment services. In addition, the TCR executes first-line interventions on the entire CERN site. Troubleshooting requests are transmitted to the TCR either via a computerised control system or via the phone number '72201'. More than 10'000 such requests are dispatched and dealt with every year. The TCR's diverse field of activity concerns the following systems: electrical and fluid distribution networks, heating, cooling, ventilation, air-conditioning and gas equipment, safety and communication installations, electromechanical systems (e.g. lifts, cranes, machine tools, motorised doors), sanitary systems (leaks, sewage), control and monitoring infrastructure equipment, buildings. These systems can either be part of the administrative infrastructure, such as offices or restaurants, or part of the t...

  16. CERN'S TECHNICAL CONTROL ROOM (TCR) A CENTRAL SERVICE FOR EVERYONE

    CERN Multimedia

    Mario Batz

    2001-01-01

    The Technical Control Room (TCR) monitors and operates the entire technical infrastructure of CERN 24 hours a day, 365 days a year. It registers and dispatches troubleshooting requests to the appropriate equipment services. In addition, the TCR executes first-line interventions on the entire CERN site. Troubleshooting requests are transmitted to the TCR either via a computerised control system or via the phone number '72201'. More than 10'000 such requests are dispatched and dealt with every year. The TCR's diverse field of activity concerns the following systems: electrical and fluid distribution networks, heating, cooling, ventilation, air-conditioning and gas equipment, safety and communication installations, electromechanical systems (e.g. lifts, cranes, machine tools, motorised doors), sanitary systems (leaks, sewage), control and monitoring infrastructure equipment, buildings. These systems can either be part of the administrative infrastructure, such as offices or restaurants, or part of the t...

  17. CERN'S TECHNICAL CONTROL ROOM (TCR) A CENTRAL SERVICE FOR EVERYONE

    CERN Multimedia

    Mario Batz

    2002-01-01

    The Technical Control Room (TCR) monitors and operates the entire technical infrastructure of CERN 24 hours a day, 365 days a year. It registers and dispatches troubleshooting requests to the appropriate CERN equipment services or contractors. In addition, the TCR executes first-line interventions on the entire CERN site. Troubleshooting requests are transmitted to the TCR either via a computerised control system or via the phone number '72201'. More than 10'000 such requests are dispatched and dealt with every year. The TCR's diverse field of activity covers the following systems: electrical and fluid distribution networks, heating, cooling, ventilation, air-conditioning and gas equipment, safety and communication installations, electromechanical systems (e.g. lifts, cranes, machine tools, motorised doors), sanitary systems (leaks, sewage), control and monitoring infrastructure equipment, and buildings. These systems can either be part of the administrative infrastructure, such as offices or restaur...

  18. Active low frequency sound field control in a listening room using CABS (Controlled Acoustic Bass System) will also reduce the sound transmitted to neighbour rooms

    DEFF Research Database (Denmark)

    Nielsen, Sofus Birkedal; Celestinos, Adrian

    2012-01-01

    Sound in rooms and transmission of sound between rooms gives the biggest problems at low frequencies. Rooms with rectangular boundaries have strong resonance frequencies and will give big spatial variations in sound pressure level (SPL) in the source room, and an increase in SPL of 20 dB at a wal...... shown a reduction in sound transmission of up to 10 dB at resonance frequencies and a reduction at broadband noise of 3 – 5 dB at frequencies up to 100 Hz. The ideas and understanding of the CABS system will also be given....... is possible at modal frequencies. For that reason the modal frequencies in the source room will also have big impact on the transmission to neighbour rooms. These low frequency resonance frequencies are very audible in the source room but also in neighbour rooms as a booming bass. CABS (Controlled Acoustic...

  19. 75 FR 69912 - Pipeline Safety: Control Room Management/Human Factors

    Science.gov (United States)

    2010-11-16

    ... Safety: Control Room Management/Human Factors AGENCY: Pipeline and Hazardous Materials Safety..., 2010, PHMSA published a Control Room Management/Human Factors notice of proposed rulemaking (NPRM... to expedite the program implementation deadlines of the Control Room Management/Human Factors rule...

  20. 75 FR 5536 - Pipeline Safety: Control Room Management/Human Factors, Correction

    Science.gov (United States)

    2010-02-03

    ... Safety: Control Room Management/Human Factors, Correction AGENCY: Pipeline and Hazardous Materials Safety... Regulations to address human factors and other aspects of control room management for pipelines where... 63310) entitled ``Pipeline Safety: Control Room Management/Human Factors.'' This final rule...

  1. MODERN MEANS OF EXPRESSIVE ORAL SPEECH CONTROL

    Directory of Open Access Journals (Sweden)

    Nadehzda Yurevna Gutareva

    2013-09-01

    Full Text Available The notion “an oral communicative test in the form of interview” is carried out from linguistics, methods of teaching foreign languages and physiology point of view in the article. The basic components of foreign communicative competence are indicated in the works of Russian and foreign scientists, and the new component parts are added that are actual for a specialist of nonlinguistic institute of higher education. The author of the work also dwells on the concept that there are two types of oral communicative tests in the form of interview and in the form of role playing game in the modern lingvo-didactic testing and the choice of this and that form always depends on purpose, objects and stage of testing and teaching. Purpose: to determine the basic advantages of using oral communicative tests in the form of interview. Methodology: studying and analysis of linguistic, psychological, pedagogical and methodological literature on the theme of investigation, questionnaire and testing of students. Results: the analysis of the purpose and functions of using oral communicative tests in the form of interview has shown importance of their application in practice.Practical implications: it is possible for us to use the results of this work in courses of theory of methodology of teaching foreign languages.DOI: http://dx.doi.org/10.12731/2218-7405-2013-8-16

  2. About Modern Graphic Reconstruction Wall Painting Of The Throne -Room Of Afrasiab

    Directory of Open Access Journals (Sweden)

    Sultanova Dilshoda

    2015-07-01

    Full Text Available Abstract In article are considered bases scientifically-creative reconstruction of pre-Islamic paintings hall of ambassadors of Afrasiab executed in interior foyer of institute of Archaeology RUZ.As a result of benchmark analysis modern painting with original museum of Afrasiab possible to define not before our days of a part and fragments in holistic type that is to say in beginning what looked before destruction arabic conqueror. Afrasiab paintings as specific facility more than 16 centuries is studied in our republic and has a questions which wait their own decisions.The author presents for the first time in picturesque manner to your attention its interpretation painting coming from its scientifically-creative experience.Given exploratory work possible consider as significant contribution to science on archaeology architecture and art.

  3. SYSTEMATIZATION OF MODERN CONCEPT OF THE CONTROLLING

    Directory of Open Access Journals (Sweden)

    Kuzina A. F.

    2014-09-01

    Full Text Available The article gives an overview of the results of the comparison of singularities of the American and the German model controlling, we have also revealed the pros and cons of these concepts

  4. Development of DMC controllers for temperature control of a room deploying the displacement ventilation HVAC system

    Directory of Open Access Journals (Sweden)

    Zhicheng Li, Ramesh K. Agarwal, Huijun Gao

    2013-01-01

    Full Text Available In this paper, by developing a new Dynamic Matrix Control (DMC method, we develop a controller for temperature control of a room cooled by a displacement ventilation HVAC system. The fluid flow and heat transfer inside the room are calculated by solving the Reynolds-Averaged Navier-Stokes (RANS equations including the effects of buoyancy in conjunction with a two-equation realizable k - epsilon turbulence model. Thus the physical environment is represented by a nonlinear system of partial differential equations. The system also has a large time delay because of the slowness of the heat exchange. The goal of the paper is to develop a controller that will maintain the temperature at three points near three different walls in a room within the specified upper and lower bounds. In order to solve this temperature control problem at three different points in the room, we develop a special DMC method. The results show that the newly developed DMC controller is an effective controller to maintain temperature within desired bounds at multiple points in the room and also saves energy when compared to other controllers. This DMC method can also be employed to develop controllers for other HVAC systems such as the overhead VAV (Variable Air Volume system and the radiant cooling hydronic system.

  5. Development of DMC controllers for temperature control of a room deploying the displacement ventilation HVAC system

    Energy Technology Data Exchange (ETDEWEB)

    Li, Zhicheng; Agarwal, Ramesh K. [Department of Mechanical Engineering and Materials Science, Washington University in Saint Louis, MO 63130 (United States); Gao, Huijun [Research Institute of Intelligent Control and Systems, Harbin Institute of Technology, Harbin 150001 (China)

    2013-07-01

    In this paper, by developing a new Dynamic Matrix Control (DMC) method, we develop a controller for temperature control of a room cooled by a displacement ventilation HVAC system. The fluid flow and heat transfer inside the room are calculated by solving the Reynolds-Averaged Navier-Stokes (RANS) equations including the effects of buoyancy in conjunction with a two-equation realizable k - epsilon turbulence model. Thus the physical environment is represented by a nonlinear system of partial differential equations. The system also has a large time delay because of the slowness of the heat exchange. The goal of the paper is to develop a controller that will maintain the temperature at three points near three different walls in a room within the specified upper and lower bounds. In order to solve this temperature control problem at three different points in the room, we develop a special DMC method. The results show that the newly developed DMC controller is an effective controller to maintain temperature within desired bounds at multiple points in the room and also saves energy when compared to other controllers. This DMC method can also be employed to develop controllers for other HVAC systems such as the overhead VAV (Variable Air Volume) system and the radiant cooling hydronic system.

  6. Modernization of B-2 Data, Video, and Control Systems Infrastructure

    Science.gov (United States)

    Cmar, Mark D.; Maloney, Christian T.; Butala, Vishal D.

    2012-01-01

    The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) Plum Brook Station (PBS) Spacecraft Propulsion Research Facility, commonly referred to as B-2, is NASA s third largest thermal-vacuum facility with propellant systems capability. B-2 has completed a modernization effort of its facility legacy data, video and control systems infrastructure to accommodate modern integrated testing and Information Technology (IT) Security requirements. Integrated systems tests have been conducted to demonstrate the new data, video and control systems functionality and capability. Discrete analog signal conditioners have been replaced by new programmable, signal processing hardware that is integrated with the data system. This integration supports automated calibration and verification of the analog subsystem. Modern measurement systems analysis (MSA) tools are being developed to help verify system health and measurement integrity. Legacy hard wired digital data systems have been replaced by distributed Fibre Channel (FC) network connected digitizers where high speed sampling rates have increased to 256,000 samples per second. Several analog video cameras have been replaced by digital image and storage systems. Hard-wired analog control systems have been replaced by Programmable Logic Controllers (PLC), fiber optic networks (FON) infrastructure and human machine interface (HMI) operator screens. New modern IT Security procedures and schemes have been employed to control data access and process control flows. Due to the nature of testing possible at B-2, flexibility and configurability of systems has been central to the architecture during modernization.

  7. Modernization of B-2 Data, Video, and Control Systems Infrastructure

    Science.gov (United States)

    Cmar, Mark D.; Maloney, Christian T.; Butala, Vishal D.

    2012-01-01

    The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) Plum Brook Station (PBS) Spacecraft Propulsion Research Facility, commonly referred to as B-2, is NASA's third largest thermal-vacuum facility with propellant systems capability. B-2 has completed a modernization effort of its facility legacy data, video and control systems infrastructure to accommodate modern integrated testing and Information Technology (IT) Security requirements. Integrated systems tests have been conducted to demonstrate the new data, video and control systems functionality and capability. Discrete analog signal conditioners have been replaced by new programmable, signal processing hardware that is integrated with the data system. This integration supports automated calibration and verification of the analog subsystem. Modern measurement systems analysis (MSA) tools are being developed to help verify system health and measurement integrity. Legacy hard wired digital data systems have been replaced by distributed Fibre Channel (FC) network connected digitizers where high speed sampling rates have increased to 256,000 samples per second. Several analog video cameras have been replaced by digital image and storage systems. Hard-wired analog control systems have been replaced by Programmable Logic Controllers (PLC), fiber optic networks (FON) infrastructure and human machine interface (HMI) operator screens. New modern IT Security procedures and schemes have been employed to control data access and process control flows. Due to the nature of testing possible at B-2, flexibility and configurability of systems has been central to the architecture during modernization.

  8. HFE safety reviews of advanced nuclear power plant control rooms

    Science.gov (United States)

    Ohara, John

    1994-01-01

    Advanced control rooms (ACR's) will utilize human-system interface (HSI) technologies that may have significant implications for plant safety in that they will affect the operator's overall role and means of interacting with the system. The Nuclear Regulatory Commission (NRC) reviews the human factors engineering (HFE) aspects of HSI's to ensure that they are designed to good HFE principles and support performance and reliability in order to protect public health and safety. However, the only available NRC guidance was developed more than ten years ago, and does not adequately address the human performance issues and technology changes associated with ACR's. Accordingly, a new approach to ACR safety reviews was developed based upon the concept of 'convergent validity'. This approach to ACR safety reviews is described.

  9. Diffusion and Evaporation-Controlled Emission in Ventilated Rooms

    DEFF Research Database (Denmark)

    Topp, Claus

    In emission studies reported in literature little effort has been made to investigate the emission from building materials in ventilated enclosures from a fluid dynamics point of view. Furthermore, most of the existing emission models are empirical relations that are based on specific pollutants...... change rate, local air velocity and local turbulence intensity as the mass transfer coefficient increases in proportion to these parameters. The experimental results moreover exhibit the behaviour of a diffusion-controlled emission process at the end of the experiments. A simplified version of the model...... and sources. This work provides an investigation based on fundamental fluid dynamics and mass transfer theory to obtain a general understanding of the mechanisms involved in the emission from building materials in ventilated rooms. In addition, a generally applicable model for prediction of surface emission...

  10. Design and implementation of new control room system in Damavand tokamak

    Science.gov (United States)

    Rasouli, H.; Zamanian, H.; Gheidi, M.; Kheiri-Fard, M.; Kouhi, A.

    2017-07-01

    The aim of this paper is design and implementation of an up-to-date control room. The previous control room had a lot of constraints and it was not apposite to the sophisticated diagnostic systems as well as to the modern control and multivariable systems. Although it provided the best output for the considered experiments and implementing offline algorithms among all similar plants, it needed to be developed to provide more capability for complex algorithm mechanisms and this work introduces our efforts in this area. Accordingly, four leading systems were designed and implemented, including real-time control system, online Data Acquisition System (DAS), offline DAS, monitoring and data transmission system. In the control system, three real-time control modules were established based on Digital Signal Processor (DSP). Thanks to them, implementation of the classic and linear and nonlinear intelligent controllers was possible to control the plasma position and its elongation. Also, online DAS was constructed in two modules. Using them, voltages and currents of charge for the capacitor banks and pressure of different parts in vacuum vessel were measured and monitored. Likewise, by real-time processing of the online data, the safety protocol of plant performance was accomplished. In addition, the offline DAS was organized in 13 modules based on Field Programmable Gate Array (FPGA). This system can be used for gathering all diagnostic, control, and performance data in 156 channels. Data transmission system and storing mechanism in the server was provided by data transmitting network and MDSplus standard protocol. Moreover, monitoring software was designed so that it could display the required plots for physical analyses. Taking everything into account, this new platform can improve the quality and quantity of research activities in plasma physics for Damavand tokamak.

  11. Adaptive Backstepping Flight Control for Modern Fighter Aircraft

    NARCIS (Netherlands)

    Sonneveldt, L.

    2010-01-01

    The main goal of this thesis is to investigate the potential of the nonlinear adaptive backstepping control technique in combination with online model identification for the design of a reconfigurable flight control system for a modern fighter aircraft. Adaptive backstepping is a recursive,

  12. Mission Operations Control Room Activities during STS-2 mission

    Science.gov (United States)

    1981-01-01

    Mission Operations Control Room (MOCR) activities during STS-2 mission. Overall view of the MOCR in the Johnson Space Center's Mission Control Center. At far right is Eugene F. Kranz, Deputy Director of Flight Operations. At the flight director console in front of Kranz's FOD console are Flight Directors M.P. Frank, Neil B. Hutchinson and Donald R. Puddy as well as others (39506); Wide-angle view of flight controllers in the MOCR. Clifford E. Charlesworth, JSC Deputy Director, huddles with several flight directors for STS-2 at the flight director console. Kranz, is at far right of frame (39507); Dr. Christopher C. Kraft, Jr., JSC Director, center, celebrates successful flight and landing of STS-2 with a cigar in the MOCR. He is flanked by Dr. Maxime A Faget, left, Director of Engineering and Development, and Thomas L. Moser, of the Structures and Mechanics Division (39508); Flight Director Donald R. Puddy, near right, holds replica of the STS-2 insignia. Insignias on the opposite wall

  13. Robust isothermal electric control of exchange bias at room temperature

    Science.gov (United States)

    Binek, Christian

    2011-03-01

    Voltage-controlled spintronics is of particular importance to continue progress in information technology through reduced power consumption, enhanced processing speed, integration density, and functionality in comparison with present day CMOS electronics. Almost all existing and prototypical solid-state spintronic devices rely on tailored interface magnetism, enabling spin-selective transmission or scattering of electrons. Controlling magnetism at thin-film interfaces, preferably by purely electrical means, is a key challenge to better spintronics. Currently, most attempts to electrically control magnetism focus on potentially large magnetoelectric effects of multiferroics. We report on our interest in magnetoelectric Cr 2 O3 (chromia). Robust isothermal electric control of exchange bias is achieved at room temperature in perpendicular anisotropic Cr 2 O3 (0001)/CoPd exchange bias heterostructures. This discovery promises significant implications for potential spintronics. From the perspective of basic science, our finding serves as macroscopic evidence for roughness-insensitive and electrically controllable equilibrium boundary magnetization in magnetoelectric antiferromagnets. The latter evolves at chromia (0001) surfaces and interfaces when chromia is in one of its two degenerate antiferromagnetic single domain states selected via magnetoelectric annealing. Theoretical insight into the boundary magnetization and its role in electrically controlled exchange bias is gained from first-principles calculations and general symmetry arguments. Measurements of spin-resolved ultraviolet photoemission, magnetometry at Cr 2 O3 (0001) surfaces, and detailed investigations of the unique exchange bias properties of Cr 2 O3 (0001)/CoPd including its electric controllability provide macroscopically averaged information about the boundary magnetization of chromia. Laterally resolved X-ray PEEM and temperature dependent MFM reveal detailed microscopic information of the chromia

  14. Low frequency sound reproduction in irregular rooms using CABS (Control Acoustic Bass System)

    DEFF Research Database (Denmark)

    Celestinos, Adrian; Nielsen, Sofus Birkedal

    2011-01-01

    loudspeakers well positioned at the end of the room a virtual array is formed propagating plane waves along the length of the room in one direction. This will correct the sound field distribution in the room. When plane wave arrives to the end wall two more loudspeakers have to be placed connected......Early investigations on low frequency sound reproduction in rectangular rooms using CABS (Controlled Acoustic Bass System) have shown good results on simulations and measurements in real rooms. CABS takes the advantage of having a rectangular room with parallel walls. By using two low frequency...... with the same signal in counter phase and with a delay corresponding to approximately the length of the room. This is to cancel the reflection and maintain the plane wave propagating along the room. Real life rooms are not necessary rectangular and can be of different shapes. In this paper simulations...

  15. Robust isothermal electric control of exchange bias at room temperature

    Energy Technology Data Exchange (ETDEWEB)

    He, X.; Vescovo, E.; Wang, Y.; Caruso, A.N.; Belashchenko, K.D.; Dowben, P.A.; Binek, C.

    2010-06-20

    Voltage-controlled spin electronics is crucial for continued progress in information technology. It aims at reduced power consumption, increased integration density and enhanced functionality where non-volatile memory is combined with high-speed logical processing. Promising spintronic device concepts use the electric control of interface and surface magnetization. From the combination of magnetometry, spin-polarized photoemission spectroscopy, symmetry arguments and first-principles calculations, we show that the (0001) surface of magnetoelectric Cr{sub 2}O{sub 3} has a roughness-insensitive, electrically switchable magnetization. Using a ferromagnetic Pd/Co multilayer deposited on the (0001) surface of a Cr{sub 2}O{sub 3} single crystal, we achieve reversible, room-temperature isothermal switching of the exchange-bias field between positive and negative values by reversing the electric field while maintaining a permanent magnetic field. This effect reflects the switching of the bulk antiferromagnetic domain state and the interface magnetization coupled to it. The switchable exchange bias sets in exactly at the bulk Neel temperature.

  16. Robust isothermal electric control of exchange bias at room temperature.

    Science.gov (United States)

    He, Xi; Wang, Yi; Wu, Ning; Caruso, Anthony N; Vescovo, Elio; Belashchenko, Kirill D; Dowben, Peter A; Binek, Christian

    2010-07-01

    Voltage-controlled spin electronics is crucial for continued progress in information technology. It aims at reduced power consumption, increased integration density and enhanced functionality where non-volatile memory is combined with high-speed logical processing. Promising spintronic device concepts use the electric control of interface and surface magnetization. From the combination of magnetometry, spin-polarized photoemission spectroscopy, symmetry arguments and first-principles calculations, we show that the (0001) surface of magnetoelectric Cr(2)O(3) has a roughness-insensitive, electrically switchable magnetization. Using a ferromagnetic Pd/Co multilayer deposited on the (0001) surface of a Cr(2)O(3) single crystal, we achieve reversible, room-temperature isothermal switching of the exchange-bias field between positive and negative values by reversing the electric field while maintaining a permanent magnetic field. This effect reflects the switching of the bulk antiferromagnetic domain state and the interface magnetization coupled to it. The switchable exchange bias sets in exactly at the bulk Néel temperature.

  17. Low frequency sound reproduction in irregular rooms using CABS (Control Acoustic Bass System)

    DEFF Research Database (Denmark)

    Celestinos, Adrian; Nielsen, Sofus Birkedal

    2011-01-01

    Early investigations on low frequency sound reproduction in rectangular rooms using CABS (Controlled Acoustic Bass System) have shown good results on simulations and measurements in real rooms. CABS takes the advantage of having a rectangular room with parallel walls. By using two low frequency l...

  18. The design of an embedded system for controlling humidity and temperature room

    Science.gov (United States)

    Dwi Teguh, R.; Didik Eko, S.; Laksono, Pringgo D.; Jamaluddin, Anif

    2016-11-01

    The aim of the system is to design an embedded system for maintenance confortable room. The confortable room was design by controlling temperature (on range 18 - 34 °C) and humidity (on range 40% - 70%.) of room condition. Temperature and humidity of room were maintained using four variable such as lamp for warm, water pump for distributing water vapour, a fan for air circullation and an exhaust-fan for air cleaner. The system was constucted both hardware (humidity sensor, microcontroller, pump, lamp, fan) and software (arduino IDE). The result shows that the system was perfectly performed to control room condition.

  19. Progress of a room temperature electron cyclotron resonance ion source using evaporative cooling technology at Institute of Modern Physics

    Energy Technology Data Exchange (ETDEWEB)

    Lu, W., E-mail: luwang@impcas.ac.cn [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 73000 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Xiong, B.; Guo, S. Q.; Cao, R.; Ruan, L. [Institute of Electrical Engineering, CAS, Beijing 100190 (China); Zhang, X. Z.; Sun, L. T.; Feng, Y. C.; Ma, B. H.; Zhao, H. W. [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 73000 (China)

    2014-02-15

    A new room temperature ECR ion source, Lanzhou Electron Cyclotron Resonance ion source No. 4 (LECR4, previously named DRAGON), is under intense construction at Institute of Modern Physics. LECR4 is designed to operate with 18 GHz microwave frequency. The maximum axial magnetic fields are 2.3 T at injection and 1.3 T at extraction, and the radial field at the plasma chamber wall of 76 mm inner diameter is 1.0–1.2 T. One of the unique features for LECR4 is that its axial solenoids are winded with solid square copper wires which are immersed in a kind of special evaporative cooling medium for cooling purpose. Till now, a prototype of the cooling system has been successfully constructed and tested, which has demonstrated that the cooling efficiency of the designed system could meet the requirements of LECR4 under the routine operation conditions. All the main components of the ion source have been completed. Assembly and commissioning is ongoing. The latest developments and test results will be presented in this paper.

  20. Progress of a room temperature electron cyclotron resonance ion source using evaporative cooling technology at Institute of Modern Physics.

    Science.gov (United States)

    Lu, W; Xiong, B; Zhang, X Z; Sun, L T; Feng, Y C; Ma, B H; Guo, S Q; Cao, R; Ruan, L; Zhao, H W

    2014-02-01

    A new room temperature ECR ion source, Lanzhou Electron Cyclotron Resonance ion source No. 4 (LECR4, previously named DRAGON), is under intense construction at Institute of Modern Physics. LECR4 is designed to operate with 18 GHz microwave frequency. The maximum axial magnetic fields are 2.3 T at injection and 1.3 T at extraction, and the radial field at the plasma chamber wall of 76 mm inner diameter is 1.0-1.2 T. One of the unique features for LECR4 is that its axial solenoids are winded with solid square copper wires which are immersed in a kind of special evaporative cooling medium for cooling purpose. Till now, a prototype of the cooling system has been successfully constructed and tested, which has demonstrated that the cooling efficiency of the designed system could meet the requirements of LECR4 under the routine operation conditions. All the main components of the ion source have been completed. Assembly and commissioning is ongoing. The latest developments and test results will be presented in this paper.

  1. Low frequency sound field control in rectangular listening rooms using CABS (Controlled Acoustic Bass System) will also reduce sound transmission to neighbor rooms

    DEFF Research Database (Denmark)

    Nielsen, Sofus Birkedal; Celestinos, Adrian

    2011-01-01

    at resonance frequencies, but more or less at all frequencies. A time based room correction system named CABS (Controlled Acoustic Bass System) has been developed and is able to create a homogeneous sound field in the whole room at low frequencies by proper placement of multiple loudspeakers. A normal setup...... from the rear wall, and thereby leaving only the plane wave in the room. With a room size of (7.8 x 4.1 x 2.8) m. it is possible to prevent modal frequencies up to 100 Hz. An investigation has shown that the sound transmitted to a neighbour room also will be reduced if CABS is used. The principle...... and the understanding of why and how it works will also be discussed. CABS is controlled by a developed DSP (Digital Signal Processing) system....

  2. Exploring Bridge-Engine Control Room Collaborative Team Communication

    Directory of Open Access Journals (Sweden)

    Aditi Kataria

    2015-06-01

    Full Text Available The EC funded CyClaDes research project is designed to promote the increased impact of the human element in shipping across the design and operational lifecycle. It addresses the design and operation of ships and ship systems. One of the CyClaDes’ tasks is to create a crew-centered design case-study examination of the information that is shared between the Bridge and Engine Control Room that helps the crew co-ordinate to ensure understanding and complete interconnected tasks. This information can be provided in various ways, including communication devices or obtained from a common database, display, or even the ship environment (e.g., the roll of the ship. A series of semi-structured interviews were conducted with seafarers of diverse ranks to get a better idea of what communication does, or should, take place and any problems or challenges existing in current operations, as seen from both the bridge and ECR operators’ perspectives. Included in the interview were both the standard communications and information shared during planning and executing a voyage, as well as special situations such as safety/casualty tasks or heavy weather. The results were analyzed in terms of the goals of the communication, the primary situations of interest for communication and collaboration, the communication media used, the information that is shared, and the problems experienced. The results of seafarer interviews are presented in the paper to explore on-board inter-departmental communication.

  3. Emergency control room design of a nuclear reactor used to produce radioisotope

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Isaac J.A.L. dos; Farias, Larissa P. de; Ponte, Luana T.L.; Goncalves, Gabriel L.; Castro, Heraclito M.; Farias, Marcos S.; Carvalho, Paulo V.R. de; Vianna Filho, Alfredo M.V., E-mail: luquetti@ien.gov.br [Instituto Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Departamento Engenharia Nuclear

    2015-07-01

    A control room is defined as a functional entity with an associated physical structure, where the operators carry out the centralized control, monitoring and administrative responsibilities. Emergency control room acts as an alternative control room for the purpose of shutting down or maintaining the facility in a safe shutdown state when the main control room is uninhabitable. The mission of emergency control room is to provide the resources to bring the plant to a safe shutdown condition after an evacuation of the main control room. An evacuation of the main control room is assumed when there is no possibility to accomplish tasks involved in the shutdown except reactor trip. The purpose of this paper is to present a specific approach for the design of the emergency control room of a nuclear reactor used to produce radioisotope. The approach is based on human factors standards and the participation of a multidisciplinary team in the development phase of the design. Using the information gathered from standards and from the multidisciplinary team a 3D Sketch and a 3D printing of the emergency control room were created. (author)

  4. Human factors design review guidelines for advanced nuclear control room technologies

    Energy Technology Data Exchange (ETDEWEB)

    O' Hara, J.; Brown, W. (Brookhaven National Lab., Upton, NY (United States)); Granda, T.; Baker, C. (Carlow Associates, Inc., Fairfax, VA (United States))

    1991-01-01

    Advanced control rooms (ACRs) for future nuclear power plants are being designed utilizing computer-based technologies. The US Nuclear Regulatory Commission reviews the human engineering aspects of such control rooms to ensure that they are designed to good human factors engineering principles and that operator performance and reliability are appropriately supported in order to protect public health and safety. This paper describes the rationale, general approach, and initial development of an NRC Advanced Control Room Design Review Guideline. 20 refs., 1 fig.

  5. Low frequency sound field control in rectangular listening rooms using CABS (Controlled Acoustic Bass System) will also reduce sound transmission to neighbor rooms

    DEFF Research Database (Denmark)

    Nielsen, Sofus Birkedal; Celestinos, Adrian

    2011-01-01

    from the rear wall, and thereby leaving only the plane wave in the room. With a room size of (7.8 x 4.1 x 2.8) m. it is possible to prevent modal frequencies up to 100 Hz. An investigation has shown that the sound transmitted to a neighbour room also will be reduced if CABS is used. The principle......Sound reproduction is often taking place in small and medium sized rectangular rooms. As rectangular rooms have 3 pairs of parallel walls the reflections at especially low frequencies will cause up to 30 dB spatial variations of the sound pressure level in the room. This will take place not only...... at resonance frequencies, but more or less at all frequencies. A time based room correction system named CABS (Controlled Acoustic Bass System) has been developed and is able to create a homogeneous sound field in the whole room at low frequencies by proper placement of multiple loudspeakers. A normal setup...

  6. Advancement in modern approaches to mineral production quality control

    Science.gov (United States)

    Freidina, EV; Botvinnik, AA; Dvornikova, AN

    2017-02-01

    The natural resource potential of mineral deposits is represented by three categories: upside, attainable and investment. A modern methodology is proposed in this paper for production quality control, and its tools aimed at ensuring agreement between the product quality and the market requirements are described. The definitions of the costs of the product quality compliance and incompliance with the consumer requirements are introduced; the latter is suggested to use in evaluating resource potential of mineral deposits at a certain degree of probability.

  7. Migration of 1970s Minicomputer Controls to Modern Toolkit Software

    Energy Technology Data Exchange (ETDEWEB)

    Juras, R.C.; Meigs, M.J.; Sinclair, J.A.; Tatum, B.A.

    1999-11-13

    Controls for accelerators and associated systems at the Holifield Radioactive Ion Beam Facility (HRIBF) at Oak Ridge National Laboratory have been migrated from 197Os-vintage minicomputers to a modern system based on Vista and EPICS toolkit software. Stability and capabilities of EPICS software have motivated increasing use of EPICS for accelerator controls. In addition, very inexpensive subsystems based on EPICS and the EPICS portable CA server running on Linux PCs have been implemented to control an ion source test facility and to control a building-access badge reader system. A new object-oriented, extensible display manager has been developed for EPICS to facilitate the transition to EPICS and will be used in place of MEDM. EPICS device support has been developed for CAMAC serial highway controls.

  8. Replacement of coal-fuelled stoves by modern room heating systems in multistorey dwellings; Abloesung der Kohle-Einzelofenheizung durch moderne Raumheizungssysteme in Mehrgeschossbauten

    Energy Technology Data Exchange (ETDEWEB)

    Lindner, K. [Institut fuer Energetik und Umwelt gGmbH, Leipzig (Germany)

    1997-12-31

    In eastern Germany, approximately one million residential units in multi-storey apartment buildings are still heated with coal-fired stoves. Not all building societies or private house-owners can afford to substitute modern heating systems for individual coal stoves within the foreseeable future. Problems encountered when modernizing heating systems are described. A way of pre-financing modernization is by loans given by the tenants to the building society. The paper deals with individual aspects, such as contract conditions, organization and experience with this model, as well as its advantages for the landlord and tenant. (MSK) [Deutsch] In Ostdeutschland werden noch rund 1 Million Wohnungen in mehrgeschossigen Wohnhaeuern mit Kohle geheizt. Nicht alle Wohnungsgenossenschaften oder privaten Hauseigentuemer sind finanziell in der Lage in absehbarer Zeit die Kohle-Einzelheizung durch moderne Heizungssysteme abzuloesen. Im Folgenden werden die Probleme bei der Heizungsmodernisierung beschrieben. Der Weg Heizungsmodernisierung durch Mieterdarlehen wird in einzelnen Punkten wie Finanzierung durch Mieterdarlehen, deren Organisation und Erfahrungen mit diesem Modell sowie die Vorteile fuer Vermieter und Mieter dargelegt.

  9. Review of Methods Related to Assessing Human Performance in Nuclear Power Plant Control Room Simulations

    Energy Technology Data Exchange (ETDEWEB)

    Katya L Le Blanc; Ronald L Boring; David I Gertman

    2001-11-01

    With the increased use of digital systems in Nuclear Power Plant (NPP) control rooms comes a need to thoroughly understand the human performance issues associated with digital systems. A common way to evaluate human performance is to test operators and crews in NPP control room simulators. However, it is often challenging to characterize human performance in meaningful ways when measuring performance in NPP control room simulations. A review of the literature in NPP simulator studies reveals a variety of ways to measure human performance in NPP control room simulations including direct observation, automated computer logging, recordings from physiological equipment, self-report techniques, protocol analysis and structured debriefs, and application of model-based evaluation. These methods and the particular measures used are summarized and evaluated.

  10. Near-term improvements for nuclear power plant control room annunciator systems. [PWR; BWR

    Energy Technology Data Exchange (ETDEWEB)

    Rankin, W.L.; Duvernoy, E.G.; Ames, K.R.; Morgenstern, M.H.; Eckenrode, R.J.

    1983-04-01

    This report sets forth a basic design philosophy with its associated functional criteria and design principles for present-day, hard-wired annunciator systems in the control rooms of nuclear power plants. It also presents a variety of annunciator design features that are either necessary for or useful to the implementation of the design philosophy. The information contained in this report is synthesized from an extensive literature review, from inspection and analysis of control room annunciator systems in the nuclear industry and in related industries, and from discussions with a variety of individuals who are knowledgeable about annunciator systems, nuclear plant control rooms, or both. This information should help licensees and license applicants in improving their hard-wired, control room annunciator systems as outlined by NUREG-0700.

  11. Modern linear control design a time-domain approach

    CERN Document Server

    Caravani, Paolo

    2013-01-01

    This book offers a compact introduction to modern linear control design.  The simplified overview presented of linear time-domain methodology paves the road for the study of more advanced non-linear techniques. Only rudimentary knowledge of linear systems theory is assumed - no use of Laplace transforms or frequency design tools is required. Emphasis is placed on assumptions and logical implications, rather than abstract completeness; on interpretation and physical meaning, rather than theoretical formalism; on results and solutions, rather than derivation or solvability.  The topics covered include transient performance and stabilization via state or output feedback; disturbance attenuation and robust control; regional eigenvalue assignment and constraints on input or output variables; asymptotic regulation and disturbance rejection. Lyapunov theory and Linear Matrix Inequalities (LMI) are discussed as key design methods. All methods are demonstrated with MATLAB to promote practical use and comprehension. ...

  12. Integrated open loop control and design of a food storage room

    NARCIS (Netherlands)

    Mourik, van S.; Zwart, H.; Keesman, K.J.

    2009-01-01

    Usually, control design in a food storage room takes place after the plant has been designed. However, the performance of the plant connected to the controller might be improved by simultaneous design of the plant and the controller. In the case of open loop control, expressions that describe the dy

  13. Virtual control room, the REMOT project, networking pilot studies

    NARCIS (Netherlands)

    Andree, H. M. A.; Habets, J.; Koopmans, M.; Kooijman, W.; Kemmerling, G.; Korten, M.; de Laat, C. T. A. M.; Lourens, W.; van der Meer, E. A.; Oomens, A. A. M.; Venema, J.

    1998-01-01

    The Remote Experiment Monitoring and Control (REMOT) project objective is to develop a system architecture to allow remote control of scientific experiments and facilities that require real time operation and multimedia information feedback, using available or deploying communications infrastructure

  14. Software Development for Remote Control and Firing Room Displays

    Science.gov (United States)

    Zambrano Pena, Jessica

    2014-01-01

    The Launch Control System (LCS) developed at NASA's Kennedy Space Center (KSC) will be used to launch future spacecraft. Two of the many components of this system are the Application Control Language (ACL) and remote displays. ACL is a high level domain specific language that is used to write remote control applications for LCS. Remote displays are graphical user interfaces (GUIs) developed to display vehicle and Ground Support Equipment (GSE) data, they also provide the ability to send commands to control GSE and the vehicle. The remote displays and the control applications have many facets and this internship experience dealt with several of them.

  15. Towards High Performance Processing In Modern Java Based Control Systems

    CERN Document Server

    Misiowiec, M; Buttner, M

    2011-01-01

    CERN controls software is often developed on Java foundation. Some systems carry out a combination of data, network and processor intensive tasks within strict time limits. Hence, there is a demand for high performing, quasi real time solutions. Extensive prototyping of the new CERN monitoring and alarm software required us to address such expectations. The system must handle dozens of thousands of data samples every second, along its three tiers, applying complex computations throughout. To accomplish the goal, a deep understanding of multithreading, memory management and interprocess communication was required. There are unexpected traps hidden behind an excessive use of 64 bit memory or severe impact on the processing flow of modern garbage collectors. Tuning JVM configuration significantly affects the execution of the code. Even more important is the amount of threads and the data structures used between them. Accurately dividing work into independent tasks might boost system performance. Thorough profili...

  16. The scenario-based approach adopted in the ELECTRA project for deriving innovate control room functionality

    DEFF Research Database (Denmark)

    Marinelli, Mattia; Heussen, Kai; Prostejovsky, Alexander

    2017-01-01

    . The paper intends to outline the methodology adopted, which is based on the cognitive work analysis framework, to provide an overview of the most interesting scenarios and to summarize the requirements analysis results. In order to derive required control room functionality, a set of relevant control room...... scenarios have been identified based on the Web-of-Cells control concept. We considered scenarios that challenge traditional control schemes, scenarios that caused major failures (i.e., blackouts) and scenarios that can be expected to appear in the future. For each scenario, information concerning network...

  17. Temperature distribution in Risø Flexhouse Room 3 with different heating control principles

    DEFF Research Database (Denmark)

    Simone, Angela; Rode, Carsten

    2009-01-01

    in winter and spring 2009 to study the distribution of local temperatures in the room – particularly with the purpose to compare with the temperature measured and logged by the heating control sensor which was already installed in the room. The measured data shall be used together with mathematical models...... to predict the overall dynamic thermal properties of the building. The project is part of a wider complex of projects on predicting the electricity and heating energy consumption in dwellings....

  18. Microgravity isolation system design: A modern control analysis framework

    Science.gov (United States)

    Hampton, R. D.; Knospe, C. R.; Allaire, P. E.; Grodsinsky, C. M.

    1994-01-01

    Many acceleration-sensitive, microgravity science experiments will require active vibration isolation from the manned orbiters on which they will be mounted. The isolation problem, especially in the case of a tethered payload, is a complex three-dimensional one that is best suited to modern-control design methods. These methods, although more powerful than their classical counterparts, can nonetheless go only so far in meeting the design requirements for practical systems. Once a tentative controller design is available, it must still be evaluated to determine whether or not it is fully acceptable, and to compare it with other possible design candidates. Realistically, such evaluation will be an inherent part of a necessary iterative design process. In this paper, an approach is presented for applying complex mu-analysis methods to a closed-loop vibration isolation system (experiment plus controller). An analysis framework is presented for evaluating nominal stability, nominal performance, robust stability, and robust performance of active microgravity isolation systems, with emphasis on the effective use of mu-analysis methods.

  19. Measurement of Bitumen Viscosity in a Room-Temperature Drop Experiment: Student Education, Public Outreach and Modern Science in One

    Science.gov (United States)

    Widdicombe, A. T.; Ravindrarajah, P.; Sapelkin, A.; Phillips, A. E.; Dunstan, D.; Dove, M. T.; Brazhkin, V. V.; Trachenko, K.

    2014-01-01

    The slow flow of a viscous liquid is a thought-provoking experiment that challenges students, academics and the public to think about some fundamental questions in modern science. In the Queensland demonstration--the world's longest-running experiment, which has earned the Ig Nobel prize--one drop of pitch takes about ten years to fall, leading to…

  20. 75 FR 67450 - Pipeline Safety: Control Room Management Implementation Workshop

    Science.gov (United States)

    2010-11-02

    ... associated with fatigue management and maximum hours of service, alarm management, and adequate information... Specifics. (3) Fatigue and Maximum Hours of Service (panel). (4) Alarm Management (panel). (5) Roles and... risk associated with controller fatigue. In addition, certain operators must define the roles and...

  1. Project Management Using Modern Guidance, Navigation and Control Theory

    Science.gov (United States)

    Hill, Terry

    2010-01-01

    The idea of control theory and its application to project management is not new, however literature on the topic and real-world applications is not as readily available and comprehensive in how all the principals of Guidance, Navigation and Control (GN&C) apply. This paper will address how the fundamental principals of modern GN&C Theory have been applied to NASA's Constellation Space Suit project and the results in the ability to manage the project within cost, schedule and budget. A s with physical systems, projects can be modeled and managed with the same guiding principles of GN&C as if it were a complex vehicle, system or software with time-varying processes, at times non-linear responses, multiple data inputs of varying accuracy and a range of operating points. With such systems the classic approach could be applied to small and well-defined projects; however with larger, multi-year projects involving multiple organizational structures, external influences and a multitude of diverse resources, then modern control theory is required to model and control the project. The fundamental principals of G N&C stated that a system is comprised of these basic core concepts: State, Behavior, Control system, Navigation system, Guidance and Planning Logic, Feedback systems. The state of a system is a definition of the aspects of the dynamics of the system that can change, such as position, velocity, acceleration, coordinate-based attitude, temperature, etc. The behavior of the system is more of what changes are possible rather than what can change, which is captured in the state of the system. The behavior of a system is captured in the system modeling and if properly done, will aid in accurate system performance prediction in the future. The Control system understands the state and behavior of the system and feedback systems to adjust the control inputs into the system. The Navigation system takes the multiple data inputs and based upon a priori knowledge of the input

  2. Locker Room Talk.

    Science.gov (United States)

    Fickes, Michael

    1999-01-01

    Examines the trends in college and university sports and recreation center locker rooms as envisioned by a specialist. Features of the modern locker room and the different levels of locker room design are explained. Final comments discuss whether college and university facility managers are inclined to move to high-end locker rooms. (GR)

  3. Closed-Loop Acoustic Control of Reverberant Room for Satellite Environmental Testing

    Science.gov (United States)

    Janssens, Karl; Bianciardi, Fabio; Sabbatini, Danilo; Debille, Jan; Carrella, Alex

    2012-07-01

    The full satellite acoustic test is an important milestone in a satellite launch survivability verification campaign. This test is required to verify the satellite’s mechanical design against the high-level acoustic loads induced by the launch vehicle during the atmospheric flight. During the test, the satellite is subjected to a broadband diffuse acoustic field, reproducing the pressure levels observed during launch. The excitation is in most cases provided by a combination of horns for the low frequencies and noise generators for the higher frequencies. Acoustic control tests are commonly performed in reverberant rooms, controlling the sound pressure levels in third octave bands over the specified target spectrum. This paper discusses an automatic feedback control system for acoustic control of large reverberation rooms for satellite environmental testing. The acoustic control system consists of parallel third octave PI (Proportional Integral) feedback controllers that take the reverberation characteristics of the room into consideration. The drive output of the control system is shaped at every control step based on the comparison of the average third octave noise spectrum, measured from a number of microphones in the test room, with the target spectrum. Cross-over filters split the output drive into band- limited signals to feed each of the horns. The control system is realized in several steps. In the first phase, a dynamic process model is developed, including the non-linear characteristics of the horns and the reverberant properties of the room. The model is identified from dynamic experiments using system identification techniques. In the next phase, an adequate control strategy is designed which is capable of reaching the target spectrum in the required time period without overshoots. This control strategy is obtained from model-in-the-loop (MIL) simulations, evaluating the performance of various potential strategies. Finally, the proposed strategy is

  4. 75 FR 56972 - Pipeline Safety: Control Room Management/Human Factors

    Science.gov (United States)

    2010-09-17

    ..., except for certain provisions regarding adequate information and alarm management, which would have a... must implement methods to reduce the risk associated with controller fatigue. In addition, certain... also manage alarms, assure control room considerations are taken into account when changing pipeline...

  5. Demonstration of visualization techniques for the control room engineer in 2030

    DEFF Research Database (Denmark)

    Marinelli, Mattia; Heussen, Kai; Strasser, Thomas

    2017-01-01

    Deliverable 8.1 reports results on analytics and visualizations of real time flexibility in support of voltage and frequency control in 2030+ power system. The investigation is carried out by means of relevant control room scenarios in order to derive the appropriate analytics needed for each...

  6. Evaluation of information display at advanced main control room

    Energy Technology Data Exchange (ETDEWEB)

    Min, Dae Hwan; Yu, Seon Jae; Choi, Eui Sun [Korea Univ., Seoul (Korea, Republic of)

    2000-03-15

    This year we plan to survey information in order to have basic understanding of digital information display and control at the advanced MCR. At first we collect different ways of presenting information at the advanced MCR. Secondly, we conduct literature survey on studies that have investigated information representation techniques and their effects. Then, we need compare differences between conventional NPPs and advanced NPPs. Thirdly, we need to check HMI styles and evaluation techniques that are used currently at foreign NPPs. Indeed, HMI at the advanced MCR is quite different from that at a conventional MCR. It is not desirable to apply the same evaluation technique that has veen used at the conventional MCR. We need to develop an evaluation technique that is valid in theory and applicable in practice. Finally, we identify the requirements for a support system for an HMI evaluator, since it is not easy to carry out an evaluation task even though one has firm background on cognitive engineering theories and practical experiences.

  7. Operational Strategy of CBPs for load balancing of Operators in Advanced Main Control Room

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seunghwan; Kim, Yochan; Jung, Wondea [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    With the using of a computer-based control room in an APR1400 (Advanced Pressurized Reactor-1400), the operators' behaviors in the main control room had changed. However, though the working environment of operators has been changed a great deal, digitalized interfaces can also change the cognitive tasks or activities of operators. First, a shift supervisor (SS) can confirm/check the conduction of the procedures and the execution of actions of board operators (BOs) while confirming directly the operation variables without relying on the BOs. Second, all operators added to their work the use of a new CBP and Soft Controls, increasing their procedural workload. New operational control strategies of CBPs are necessary for load balancing of operator's task load in APR1400. In this paper, we compared the workloads of operators in an APR1400 who work with two different usages of the CBP. They are SS oriented usage and SS-BO collaborative usage. In this research, we evaluated the workloads of operators in an advanced main control room by the COCOA method. Two types of CBP usages were defined and the effects of these usages on the workloads were investigated. The obtained results showed that the workloads between operators in a control room can be balanced according to the CBP usages by assigning control authority to the operators.

  8. Modernization of the NASA IRTF Telescope Control System

    Science.gov (United States)

    Pilger, Eric J.; Harwood, James V.; Onaka, Peter M.

    1994-06-01

    We describe the ongoing modernization of the NASA IR Telescope Facility Telescope Control System. A major mandate of this project is to keep the telescope available for observations throughout. Therefore, we have developed an incremental plan that will allow us to replace components of the software and hardware without shutting down the system. The current system, running under FORTH on a DEC LSI 11/23 minicomputer interfaced to a Bus and boards developed in house, will be replaced with a combination of a Sun SPARCstation running SunOS, a MicroSPARC based Single Board Computer running LynxOS, and various intelligent VME based peripheral cards. The software is based on a design philosophy originally developed by Pat Wallace for use on the Anglo Australian Telescope. This philosophy has gained wide acceptance, and is currently used in a number of observatories around the world. A key element of this philosophy is the division of the TCS into `Virtual' and `Real' parts. This will allow us to replace the higher level functions of the TCS with software running on the Sun, while still relying on the LSI 11/23 for performance of the lower level functions. Eventual transfer of lower level functions to the MicroSPARC system will then proceed incrementally through use of a Q-Bus to VME-Bus converter.

  9. A new active method for the measurement of slow-neutron fluence in modern radiotherapy treatment rooms

    Energy Technology Data Exchange (ETDEWEB)

    Gomez, F; Iglesias, A [Departamento de Fisica de Particulas, Universidad de Santiago, 15782-Santiago (Spain); Doblado, F Sanchez [Hospital Universitario Virgen Macarena, Radiofisica and Departamento de Fisiologia Medica y Biofisica, Facultad de Medicina, Universidad de Sevilla (Spain)], E-mail: faustino.gomez@usc.es

    2010-02-21

    This work focuses on neutron monitoring at clinical linac facilities during high-energy modality radiotherapy treatments. Active in-room measurement of neutron fluence is a complex problem due to the pulsed nature of the fluence and the presence of high photon background, and only passive methods have been considered reliable until now. In this paper we present a new active method to perform real-time measurement of neutron production around a medical linac. The device readout is being investigated as an estimate of patient neutron dose exposure on each radiotherapy session. The new instrument was developed based on neutron interaction effects in microelectronic memory devices, in particular using neutron-sensitive SRAM devices. This paper is devoted to the description of the instrument and measurement techniques, presenting the results obtained together with their comparison and discussion. Measurements were performed in several standard clinical linac facilities, showing high reliability, being insensitive to the photon fluence and EM pulse present inside the radiotherapy room, and having detector readout statistical relative uncertainties of about 2% on measurement of neutron fluence produced by 1000 monitor units irradiation runs.

  10. Acceptability of Low Level White Lighting in the Control Room at Sea

    Science.gov (United States)

    2014-08-05

    LIGHTING IN THE CONTROL ROOM AT SEA by S. M. Luria and D. A. Kobus Naval Medical Research and Development Command Research Work Unit M0100.001...release; distribution unlimited. ACCEPTABILITY OF LOW LEVEL WHITE LIGHTING " IN THE CONTROL ROOM AT SEA by S. M. Luria , Ph.D. David A. Kobus, LT...ltr 9330 Ser 51/434 to CO, NSMRL of 18 Nov 1984. 3 Luria , S. M. and David A. Kobus. The relative effectiveness of red and white light for

  11. Project Management Using Modern Guidance, Navigation and Control Theory

    Science.gov (United States)

    Hill, Terry R.

    2011-01-01

    Implementing guidance, navigation, and control (GN&C) theory principles and applying them to the human element of project management and control is not a new concept. As both the literature on the subject and the real-world applications are neither readily available nor comprehensive with regard to how such principles might be applied, this paper has been written to educate the project manager on the "laws of physics" of his or her project (not to teach a GN&C engineer how to become a project manager) and to provide an intuitive, mathematical explanation as to the control and behavior of projects. This paper will also address how the fundamental principles of modern GN&C were applied to the National Aeronautics and Space Administration's (NASA) Constellation Program (CxP) space suit project, ensuring the project was managed within cost, schedule, and budget. A project that is akin to a physical system can be modeled and managed using the same over arching principles of GN&C that would be used if that project were a complex vehicle, a complex system(s), or complex software with time-varying processes (at times nonlinear) containing multiple data inputs of varying accuracy and a range of operating points. The classic GN&C theory approach could thus be applied to small, well-defined projects; yet when working with larger, multiyear projects necessitating multiple organizational structures, numerous external influences, and a multitude of diverse resources, modern GN&C principles are required to model and manage the project. The fundamental principles of a GN&C system incorporate these basic concepts: State, Behavior, Feedback Control, Navigation, Guidance and Planning Logic systems. The State of a system defines the aspects of the system that can change over time; e.g., position, velocity, acceleration, coordinate-based attitude, and temperature, etc. The Behavior of the system focuses more on what changes are possible within the system; this is denoted in the state

  12. Control console for the X-ray room; Consola de control para la sala de rayos X

    Energy Technology Data Exchange (ETDEWEB)

    Garcia H, J.M.; Aguilar B, M.A.; Torres B, M.A

    1998-07-01

    It is presented the design and construction of Control console for the X-ray room of Metrology Center for ionizing radiations at National Institute of Nuclear Research (ININ). This system controls the positioning of 6 different filters for an X-ray beam. Also it controls a shutter which blockades the beam during periods established by user, these periods can be fixed from hours until tenth of second. The shutter opening periods, as well as the X-ray beam filter are establish and monitoring from a Personal computer outside of room. (Author)

  13. CMS Control Room during early morning collisions at 2.36 TeV.

    CERN Multimedia

    Richard Breedon (CMS)

    2009-01-01

    CMS recorded around 15000 collisions at 2.36 TeV with the whole detector operational, including the inner silicon systems (strips and pixels). A relatively quiet control room was still witness to excitement during the first online event displays of the collisions.

  14. Psychological factors of professional success of nuclear power plant main control room operators

    Directory of Open Access Journals (Sweden)

    Kosenkov A.A.

    2014-12-01

    Full Text Available Aim: to conduct a comparative analysis of the psychological characteristics of the most and least successful main control room operators. Material and Methods. Two NPP staff groups: the most and least successful main control room operators, who worked in routine operating conditions, were surveyed. Expert evaluation method has been applied to identify the groups. The subjects were administered the Minnesota Multiphasic Personality Inventory (MMPI, Cattell's Sixteen Personality Factor Questionnaire (16PF form A and Raven's Progressive Matrices test. Results. Numerous significant psychological differences between the groups of most and least successful control room operators were obtained: the best operators were significantly more introverted and correctly solved more logical tasks with smaller percentage of mistakes under time pressure than worst ones. Conclusions: 1. The psychodiagnostic methods used in the study were adequate to meet research objective 2. Tendency to introversion, as well as developed the ability to solve logic problems undertime pressure, apparently, are important professional qualities for control room operators. These indicators should be considered in the process of psychological selection and professional guidance of nuclear power plant operators.

  15. Gargamelle in the West Area - control room for the external electronic detectors

    CERN Multimedia

    1977-01-01

    Four electronic detectors complementing Gargamelle were installed in 1977, among them the external muon identifier (EMI), consisting of two arrays of multiwire proportional chambers separated by an iron wall (see Annual Report 1977 p. 84). The photo shows the control room close to the West Gargamelle Hall (Bld. 185).

  16. 76 FR 20588 - FDA Food Safety Modernization Act: Focus on Preventive Controls for Facilities; Public Meeting

    Science.gov (United States)

    2011-04-13

    ... HUMAN SERVICES Food and Drug Administration 21 CFR Chapter I FDA Food Safety Modernization Act: Focus on... a public meeting entitled ``FDA Food Safety Modernization Act: Focus on Preventive Controls for... implementation of the preventive controls for facilities provisions of the recently enacted FDA Food Safety...

  17. Virtual Visit to the ATLAS Control Room by various towns in Uruguay

    CERN Multimedia

    2013-01-01

    Anilla Cultural Latinoamérica – Europa in Uruguay is a venture between ANEP, CES and UDELAR. In its line of action of scientific and technological culture they contact CERN for an open dialogue to divulge science, led to its teachers and students. The virtual "visit" of Uruguay at CERN is done from multiple video conferencing rooms in the country through the Uruguayan Academic Network. On 28th May six towns in Uruguay will be connected to the ATLAS Control Room: Montevideo, Maldonado, Rocha, Tacuarembó, Salto and Rivera.

  18. MULTI - TRACER CONTROL ROOM AIR INLEAKAGE PROTOCOL AND SIMULATED PRIMARY AND EXTENDED MULTI - ZONE RESULTS.

    Energy Technology Data Exchange (ETDEWEB)

    DIETZ,R.N.

    2002-01-01

    The perfluorocarbon tracer (PFT) technology can be applied simultaneously to the wide range in zonal flowrates (from tens of cfms in some Control Rooms to almost 1,000,000 cfm in Turbine Buildings), to achieve the necessary uniform tagging for subsequent determination of the desired air inleakage and outleakage from all zones surrounding a plant's Control Room (CR). New types of PFT sources (Mega sources) were devised and tested to handle the unusually large flowrates in a number of HVAC zones in power stations. A review of the plans of a particular nuclear power plant and subsequent simulations of the tagging and sampling results confirm that the technology can provide the necessary concentration measurement data to allow the important ventilation pathways involving the Control Room and its air flow communications with all adjacent zones to be quantitatively determined with minimal uncertainty. Depending on need, a simple single or 3-zone scheme (involving the Control Room alone or along with the Aux. Bldg. and Turbine Bldg.) or a more complex test involving up to 7 zones simultaneously can be accommodated with the current revisions to the technology; to test all the possible flow pathways, several different combinations of up to 7 zones would need to be run. The potential exists that for an appropriate investment, in about 2 years, it would be possible to completely evaluate an entire power plant in a single extended multizone test with up to 12 to 13 separate HVAC zones. With multiple samplers in the Control Room near each of the contiguous zones, not only will the prevalent inleakage or outleakage zones be documented, but the particular location of the pathway's room of ingress can be identified. The suggested protocol is to perform a 3-zone test involving the Control Room, Aux. Bldg., and Turbine Bldg. to (1) verify CR total inleakage and (2) proportion that inleakage to distinguish that from the other 2 major buildings and any remaining untagged

  19. Room transfers and the risk of delirium incidence amongst hospitalized elderly medical patients: a case?control study

    OpenAIRE

    Goldberg, Amanda; Sharon E Straus; Hamid, Jemila S; Wong, Camilla L.

    2015-01-01

    Background Room transfers are suspected to promote the development of delirium in hospitalized elderly patients, but no studies have systematically examined the relationship between room transfers and delirium incidence. We used a case?control study to determine if the number of room transfers per patient days is associated with an increased incidence of delirium amongst hospitalized elderly medical patients, controlling for baseline risk factors. Methods We included patients 70?years of age ...

  20. Analysis results for the stereotypes regarding colors applied to the nuclear power plant control room

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jung Woon; Oh, In Seok; Lee, Yong Hee; Lee, Hyun Chul [KAERI, Taejon (Korea, Republic of); Lee, Dhong Ha [Suwon Univ., Suwon (Korea, Republic of)

    2003-01-01

    The general public not engaged in the nuclear power plant industry have no idea of the color usage in the nuclear control room. So we converted the specific color usage situation into similar but general situations. In questionnaire, we gave subjects the general situation where color coding is applied and alternative colors which were applied to the HF010 guidelines. And we asked the subjects to choose the colors proper to the situation and to rank the colors according to the degree of suitability. Two hundred fifty college students participated in the experiment. The results suggest that we can use any color coding system in the conventional control room and the CRT in the control deck because most people have no special previous color-meaning association but red-emergency relation.

  1. Virtual Visit to the ATLAS Control Room by the Frankfurt Book Fair

    CERN Multimedia

    ATLAS Experiment

    2012-01-01

    The Frankfurt book fair is the largest of its kind in Germany, attracting about 300,000 visitors during five days. CERN will be present with a large stand, incorporating a virtual LHC control centre, a table featuring books on CERN for the general public, an interactive LHC tunnel and a presentation stage. Every 2 hours, a CERN physicist will give a short presentation on CERN and LHC physics, which includes a live link to the control rooms of ATLAS or CMS, or the CERN control room. This will give visitors of the book fair the opportunity to ask questions about the LHC, the LHC experiments, Higgs particles or anything else they would like to know. http://atlas-live-virtual-visit.web.cern.ch/atlas-live-virtual-visit/2012/Frankfurt-2012.html

  2. Multichannel active control of random noise in a small reverberant room

    DEFF Research Database (Denmark)

    Laugesen, Søren; Elliott, Stephen J.

    1993-01-01

    An algorithm for multichannel adaptive IIR (infinite impulse response) filtering is presented and applied to the active control of broadband random noise in a small reverberant room. Assuming complete knowledge of the primary noise, the theoretically optimal reductions of acoustic energy...... multichannel FIR (finite impulse response) and IIR filters are then compared for a four-secondary-source, eight-error microphone active control system, and it is found that for the present application FIR filters are sufficient when the primary noise source is a loudspeaker. Some experiments are then presented...... with the primary noise field generated by a panel excited by a loudspeaker in an adjoining room. These results show that far better performances are provided by IIR and FIR filters when the primary source has a lightly damped dynamic behavior which the active controller must model...

  3. Room acoustic analysis of blower unit and noise control plan in the typical steel industry

    Directory of Open Access Journals (Sweden)

    2013-02-01

    Full Text Available Introduction: In the steel industry,air blowers used to supply compressed air are considered as sources of annoying noise. This study aims to acoustics analysis of theairblower workroomand sound source characteristics in order to present noise controlmeasuresinthe steel industry. .Material and Method: Measurement of noiselevel and its frequency analysis was performed usingsound levelmetermodelof CASELLA-Cell.450. Distribution of noise level in the investigated workroom in form of noise map was provided using Surfer software. In addition, acoustic analysis of workroom and control room was performed in view point of soundabsorption andinsulation. Redesignofdoor and window of controlroom and installation of soundabsorbing materialson theceiling of the workroom were proposed and the efficiency of these interventionswasestimated. .Result: The totalsound pressurelevelin the blower workroom was 95.4 dB(L and the dominant frequency was 2000Hz. Sound pressure level inside the room control was 80.1dB(A. The average absorption coefficient and reverberation time in the blower workroom was estimated equal to 0.082 Sab.m2 and 3.9 seconds respectively. These value in control room was 0.04 Sab.m2 and 3/4 seconds respectively. In control room, sound transmission loss between the two parts of the wall dividing was 13.7 dB(A. The average of noise dose in blower operators was 230%. With the installation of sound absorber on ceiling of workroom, average of absorption coefficient can increase to 0.33 Sab.m2 and sound transmission loss of the new designed door and window was estimated equal to 20dB. . Conclusion: The main cause of noise leakage in the control room was insufficient insulation properties of door and windows. By replacing the door and window and installation of sound absorbing on ceiling of workroom, the noise dose can reduce to 49.6%. New Improved door and window of control room can reduce noise dose to 69.65% solely.

  4. Design And Implementation Of Smart Living Room Wireless Control For Safety Purpose

    Directory of Open Access Journals (Sweden)

    Aeindra Myint Lwin

    2015-07-01

    Full Text Available Abstract This research presents the microcontroller controlled smart living room system using Bluetooth wireless technology from mobile phone.An android apk is created in mobile for controlling the living room system. A 16F877A microcontroller is interfaced serially to a bluetooth module transceiver. It is used for controlling fan speed control dim light control lighting ONOFF and window angle control. An arduino controller is used for keypad control door security. It is connected to DC motor control circuit and switching circuit for opening and closing of the door keypad for entering password and serial LCD for displaying the update status of the door.User can control the home appliances by using bluetooth connection from mobile phone in its range. User can adjust the dim light fan speed window angle and light bulbs from android apk. An internal EEPROM is built in 16F877A microcontroller and it stores the last requested data of the appliances. If userwants to recover the former conditions of the appliances he can recall them from android apk.

  5. Climate control based on temperature measurement in the animal-occupied zone of a pig room with ground channel ventilation

    NARCIS (Netherlands)

    Wagenberg, van A.V.; Aerts, J.M.; Brecht, van A.; Vranken, E.; Leroy, T.; Berckmans, D.

    2005-01-01

    It is known that there can be a significant temperature difference between the position of the climate controller sensor (room temperature) and the animal-occupied zone (AOZ) in a pig room. This study explores the advantages of using AOZ temperature in climate control. The objectives were: (1) to ev

  6. Electric field control of the γ-Al2O3/SrTiO3 interface conductivity at room temperature

    DEFF Research Database (Denmark)

    Christensen, Dennis Valbjørn; Trier, Felix; von Soosten, Merlin

    2016-01-01

    Controlling interfaces using electric fields is at the heart of modern electronics. The discovery of the conducting interface between the two insulating oxides LaAlO3 (LAO) and SrTiO3 (STO) has led to a number of interesting electric field-dependent phenomena. Recently, it was shown that replacing...... LAO with a spinel γ-Al2O3 (GAO) allows a good pseudo-epitaxial film growth and high electron mobility at low temperatures. Here, we show that the GAO/STO interface resistance, similar to LAO/STO, can be tuned by orders of magnitude at room temperature using the electric field of a backgate...

  7. US NDC Modernization Iteration E1 Prototyping Report: Processing Control Framework

    Energy Technology Data Exchange (ETDEWEB)

    Prescott, Ryan [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Hamlet, Benjamin R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-12-01

    During the first iteration of the US NDC Modernization Elaboration phase (E1), the SNL US NDC modernization project team developed an initial survey of applicable COTS solutions, and established exploratory prototyping related to the processing control framework in support of system architecture definition. This report summarizes these activities and discusses planned follow-on work.

  8. Ergonomics in the licensing and evaluation of nuclear reactors control room; A ergonomia no licenciamento e na avaliacao de salas de controle de reatores nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Isaac Jose Antonio Luquetti dos [Instituto de Engenharia Nuclear (IEN), Rio de Janeiro, RJ (Brazil); Vidal, Mario Cesar Rodriguez [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia. Programa de Engenharia de Producao

    2002-07-01

    A nuclear control room is a complex system that controls a thermodynamic process used to produce electrical energy. The operators interact with the control room through interfaces that have significant implications to nuclear plant safety and influence the operator activity. The TMI (Three Mile Island) accident demonstrated that only the anthropometric aspects were not enough for an adequate nuclear control room design. The studies showed that the accident was aggravated because the designers had not considered adequately human factor aspects. After TMI accident, the designers introduce in the nuclear control room development only human factors standards and human factors guidelines. The ergonomics approaches was not considered. Our objective is introduce in nuclear control room design and nuclear control room evaluation, a methodology that. includes human factors standards, human factors guidelines and ergonomic approaches, the operator activity analysis. (author)

  9. BEYOND INTEGRATED SYSTEM VALIDATION: USE OF A CONTROL ROOM TRAINING SIMULATOR FOR PROOF-OF-CONCEPT INTERFACE DEVELOPMENT

    Energy Technology Data Exchange (ETDEWEB)

    Ronald Boring; Vivek Agarwal

    2012-07-01

    This paper provides background on a reconfigurable control room simulator for nuclear power plants. The main control rooms in current nuclear power plants feature analog technology that is growing obsolete. The need to upgrade control rooms serves the practical need of maintainability as well as the opportunity to implement newer digital technologies with added functionality. There currently exists no dedicated research simulator for use in human factors design and evaluation activities for nuclear power plants in the US. The new research simulator discussed in this paper provides a test bed in which operator performance on new control room concepts can be benchmarked against existing control rooms and in which new technologies can be validated for safety and usability prior to deployment.

  10. Control of Single-room Ventilation with Regenerative Heat Recovery for Indoor Climate and Energy Performance

    DEFF Research Database (Denmark)

    Smith, Kevin Michael; Svendsen, Svend

    2016-01-01

    exchanger. Available literature suggests that uncoated rotary heat exchangers transfer this condensate to the supply air, so the drying capacity of the ventilation system may be severely limited. This could raise indoor relative humidities to unsafe levels, which could promote the growth of dust......-mites and mould. Controls may increase drying capacity by increasing ventilation airflow, but this may not be sufficient to limit moisture-related risks. This research investigated the added demand-control measure of reducing variable heat recovery to increase drying capacity when using an uncoated rotary heat...... in these rooms, and the overall average reduction in heat recovery was less than 3%. The combined measures only succeeded in living rooms and bedrooms, and the results confirmed that rotary heat exchangers should not be used in kitchens or bathrooms, where moisture risks may be unavoidable....

  11. Virtual Visit to the ATLAS Control Room by the University of Bern

    CERN Multimedia

    ATLAS Experiment

    2012-01-01

    Fresher's day for potential future bachelor students Infotage für Studieninteressierte Bachelor Once a year the University of Bern organizes two information days for young potential future bachelor students. Young aspiring candidates interested in a career in physics will be shown the forefront of physics research, where a trip around the university physics laboratories, and a direct video link to the ATLAS Control room at CERN's Large Hadron Collider is part of the program. A physicist from Bern will present directly from the ATLAS control room for a direct and personal view into the physics at the LHC, the Higgs particle, the generation of mass, antimatter, the origin of the universe and the involvement of the Bern high-energy physics team in the ATLAS experiment. This also allows for fruitful discussions about their own perspectives of perhaps becoming a CERN physicist one day. http://atlas-live-virtual-visit.web.cern.ch/atlas-live-virtual-visit/2012/Bern-2012.html

  12. Infrared thermography evaluation from the back region of healthy horses in controlled temperature room

    Directory of Open Access Journals (Sweden)

    Mariana Pavelski

    2015-07-01

    Full Text Available The infrared thermography is a diagnostic imaging tool, which measures the surface temperature of an object through its heat emission. It is a non-invasive method, painless, with no involvement of radiation. Horses have elevated incidence of back injuries which causes decrease in their performance. A rapid and accurate diagnostic is essential to start the treatment. The aim of this paper was to establish the ideal time to the animal stay e inside a controlled room to balance their temperature and in the second time verify the thermographic temperature of specific back regions. It was studied fifteen healthy horses, being performed thermography of thoracic, lumbar and pelvic regions in four different times. There was a significant difference between the thermography performed outside and inside of the controlled temperature room. It was concluded that the ideal time to the horse stay into the controlled temperature room was thirty minutes and the mean thermographic temperatures of back regions, were obtained and can be used as parameters to identify injuries in other horses.

  13. Modern on-line control system for refuse-fueled power plants. Moderne Leittechnik fuer Muellverbrennungsanlage

    Energy Technology Data Exchange (ETDEWEB)

    Grasmueck, L. (Asea Brown Boveri AG, Mannheim (Germany, F.R.)); Klitzke, H.J. (Goepfert und Reimer und Partner, Beratende Ingenieure, Hamburg (Germany, F.R.)); Schumacher, E. (Technische Werke Ludwigshafen am Rhein AG (Germany, F.R.))

    1989-10-01

    30 years after commissioning a refuse-fueled power plant in Ludwigshafen was retrofitted and extended. A process control system provides an optimal waste combustion and flue gas cleanup. An on-line central strategy, special requirements on waste combustion and solutions are presented in this report. (orig.).

  14. Nuclear Command, Control, and Communications: Update on DOD’s Modernization

    Science.gov (United States)

    2015-06-15

    Page 1 GAO-15-584R NC3 Modernization Review 441 G St. N.W. Washington, DC 20548 June 15, 2015 Congressional Committees Nuclear Command...Control, and Communications: Update on DOD’s Modernization Nuclear command, control, and communications (NC3) is a large and complex system... architecture consists of components that support day-to-day nuclear and conventional operations prior to a nuclear event as well as those that provide

  15. Controlled Evolution of Silicon Nanocone Arrays Induced by Ar+ Sputtering at Room Temperature

    Institute of Scientific and Technical Information of China (English)

    LI Qin-Tao; LI Zhi-Gang; XIE Qiao-Ling; GONG Jin-Long; ZHU De-Zhang

    2009-01-01

    Controlled evolution of silicon nanocone arrays induced by Ar+ sputtering at room temperature, using the coating carbon as a mask, is demonstrated. The investigation of scanning electron microscopy indicates that the morphology of silicon nanostructures can be controlled by adjusting the thickness of the coating carbon film.Increasing the thickness of the coating carbon film from 50-6Onm, 250-300nm and 750-800nm to 150Onm, the morphologies of silicon nanostructures are transformed from smooth surface ripple, coarse surface ripple and surface ripple with densely distributed nanocones to nanocone arrays with a high density of about 1 × 109-2 × 109 cm-2.

  16. Control console of the gamma calibration room; Consola de control de la Sala de Calibracion Gamma

    Energy Technology Data Exchange (ETDEWEB)

    Vilchis P, A.E.; Romero G, M. [Instituto Nacional de Investigaciones Nucleares, Ingenieria Electronica, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    1999-07-01

    The Nuclear Centre of Mexico has a Ionizing Radiation Metrology Center (CMRI). This is in charge of the calibration in Mexico and Latin America of equipment dedicated to radiation measurement as industrial, medical as other fields. The importance to ensure that the equipment stay justly calibrated, it is imposed the necessity of automating the different rooms which the CMRI has. in this case it will be exposed the Calibration room for gamma radiation type. The operation of this application was carried out with the LabVIEW development platform and also in C language. The hardware associated is: personal computer with two cards using the 8255 device, 16 channels with optical isolation to manage input/output TTL type, 16 channels with optical isolation to management of charges to 127 V a.c., and 2 channels for 90V d.c. motors. (Author)

  17. Power system stabilizers based on modern control techniques

    Energy Technology Data Exchange (ETDEWEB)

    Malik, O.P.; Chen, G.P.; Zhang, Y.; El-Metwally, K. [Calgary Univ., AB (Canada). Dept. of Electrical and Computer Engineering

    1994-12-31

    Developments in digital technology have made it feasible to develop and implement improved controllers based on sophisticated control techniques. Power system stabilizers based on adaptive control, fuzzy logic and artificial networks are being developed. Each of these control techniques possesses unique features and strengths. In this paper, the relative performance of power systems stabilizers based on adaptive control, fuzzy logic and neural network, both in simulation studies and real time tests on a physical model of a power system, is presented and compared to that of a fixed parameter conventional power system stabilizer. (author) 16 refs., 45 figs., 3 tabs.

  18. Control Technologies for Room Air-conditioner and Packaged Air-conditioner

    Science.gov (United States)

    Ito, Nobuhisa

    Trends of control technologies about air-conditioning machineries, especially room or packaged air conditioners, are presented in this paper. Multiple air conditioning systems for office buildings are mainly described as one application of the refrigeration cycle control technologies including sensors for thermal comfort and heating/ cooling loads are also described as one of the system control technologies. Inverter systems and related technologies for driving variable speed compressors are described in both case of including induction motors and brushless DC motors. Technologies for more accurate control to meet various kind of regulations such as ozone layer destruction, energy saving and global warming, and for eliminating harmonic distortion of power source current, as a typical EMC problem, will be urgently desired.

  19. Airborne Contamination Control through Directed Airflow in the Exam Room: A Pilot Study Using a Membrane Diffuser

    Directory of Open Access Journals (Sweden)

    Debajyoti Pati

    2010-01-01

    Full Text Available Airborne infections have been documented as a major source of hospital acquired infection - one of the major concerns in healthcare delivery. An important factor contributing to airborne infection is cross contamination through air particulate dispersion as affected by the ventilation system design. Clean room technology (with membrane ceiling has been successfully used in technology and pharmaceutical industries to control airborne contamination. This study examined the performance of membrane ceiling technology in controlling air particulate dispersion in a mock-up exam room. It included both performance tests in a mock-up room and a simulation study of six different ventilation system designs using Computational Fluid Dynamics (CFD analysis. Findings suggest that a membrane diffuser directed airflow ventilation strategy occupying approximately 20% to 30% of the ceiling surface and placed over the patient in a contemporary sized exam room provides a less turbulent airflow pattern and less mixing of the air between the patient and others in the room.

  20. Demonstration of Intelligent Control and Fan Improvements in Computer Room Air Handlers

    Energy Technology Data Exchange (ETDEWEB)

    Coles, Henry [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Environmental Energy Technologies Division; Greenberg, Steve [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Environmental Energy Technologies Division; Vita, Corinne [Vigilent, Oakland, CA (United States)

    2012-11-30

    This report documents a demonstration of the energy-efficiency improvement provided by a new control system for computer room air handling devices. It also analyzes measured and reported air handling device fan power associated with changing the fan type. A 135,000 square foot commercial data center was used for the demonstration. All air handling units were upgraded with improved efficiency fans, and a control system that automatically adjusts the fan speed for the air handling units was added. Power measurements were collected for a baseline and for a period with the fan speed control system active. Changing the fan type resulted in a savings of 47 percent of energy used by the air handling equipment and associated chiller plant energy needed to cool the air handlers themselves. The addition of the fan speed control resulted in an additional 37 percent savings in the same two categories. The combined savings for the two improvements for the same categories was 66 percent compared to the data center fitted with the original fans without a control system. The energy use reduction provided by the complete air handling device improvement program for the whole data center site is estimated to be 2.9 million kilowatt hours per year—an overall data center site savings of 8.0 percent. The reduced electrical energy use at the site provides a 1.9 million pound yearly reduction of carbon dioxide emissions. This demonstration showed that fan upgrades and a control system addition provide cost-effective improvements for data centers, with a payback reported to be under two years without utility incentives. In addition to the control system providing energy savings, the data collection and visual analysis capabilities provided immediate and long-term benefits. It is recommended that data center operators consider investing in fan upgrades and/or adding fan speed control for computer room air handlers.

  1. Copper Selenide Nanosnakes: Bovine Serum Albumin-Assisted Room Temperature Controllable Synthesis and Characterization

    OpenAIRE

    Huang Peng; Kong Yifei; Li Zhiming; Gao Feng; Cui Daxiang

    2010-01-01

    Abstract Herein we firstly reported a simple, environment-friendly, controllable synthetic method of CuSe nanosnakes at room temperature using copper salts and sodium selenosulfate as the reactants, and bovine serum albumin (BSA) as foaming agent. As the amounts of selenide ions (Se2−) released from Na2SeSO3 in the solution increased, the cubic and snake-like CuSe nanostructures were formed gradually, the cubic nanostructures were captured by the CuSe nanosnakes, the CuSe nanosnakes gre...

  2. Coherent control in room-temperature quantum dot semiconductor optical amplifiers using shaped pulses

    CERN Document Server

    Karni, Ouri; Eisenstein, Gadi; Ivanov, Vitalii; Reithmaier, Johann Peter

    2016-01-01

    We demonstrate the ability to control quantum coherent Rabi-oscillations in a room-temperature quantum dot semiconductor optical amplifier (SOA) by shaping the light pulses that trigger them. The experiments described here show that when the excitation is resonant with the short wavelength slope of the SOA gain spectrum, a linear frequency chirp affects its ability to trigger Rabi-oscillations within the SOA: A negative chirp inhibits Rabi-oscillations whereas a positive chirp can enhance them, relative to the interaction of a transform limited pulse. The experiments are confirmed by a numerical calculation that models the propagation of the experimentally shaped pulses through the SOA.

  3. Virtual Visit to the ATLAS Control Room during the "Nuit des deux infinis", Grenoble

    CERN Multimedia

    ATLAS Experiment

    2012-01-01

    October 9, 2012 will be held the first "Night of two infinities", organized by the Laboratories of Excellence P2IO and ENIGMASS on two sites: Massy and Grenoble. This general public event will be held each year in a similar way to other "Nights" that became famous as the "Night of Museums, the "White Night "and the "Night of the Stars." During this event a short virtual visit of the ATLAS Control Room will be organized. The ACR will be briefly presented to the audience (~2000 people). A few questions will be taken from Massy and Grenoble.

  4. Virtual Visit to the ATLAS Control Room by High schools of Argos prefecture

    CERN Multimedia

    2014-01-01

    Continuing the subatomic journey that started last year in Argos, Greece, 45 students from 14 high schools of the prefecture will take part in a dedicated ATLAS Masterclass organized by the University of Athens in the framework of the Go-Lab and Inspiring Science Education European projects. Students will learn how to analyse real events from the ATLAS experiment with the use of HYPATIA online applet. They will also have the opportunity to visit the ATLAS control room to learn what it takes for scientists to keep on pushing the boundaries of our understanding of the origins of the universe.

  5. Virtual Visit to the ATLAS Control Room by 5th Lyceum in Volos

    CERN Multimedia

    2013-01-01

    The city of Volos, situated at the centre of the Greek mainland, will be hosting the 7th International Olympiad on Astronomy and Astrophysics this summer. In this context, and with support of PATHWAY and Discover the COSMOS projects, Volos` science education community is organising several pre-events aimed at bringing the world`s biggest experiments in science closer to students - the scientists of tomorrow. Senior high school students from the 5th Lyceum will have the unique opportunity to visit the ATLAS control room on the 28th March, about three months before their educational trip to CERN.

  6. Virtual Visit to the ATLAS Control Room by 3rd Gymnasium in Volos

    CERN Multimedia

    2013-01-01

    The city of Volos, situated at the centre of the Greek mainland, will be hosting the 7th International Olympiad on Astronomy and Astrophysics this summer. In this context, and with support of PATHWAY and Discover the COSMOS projects, Volos` science education community is organising several pre-events aimed at bringing the world`s biggest experiments in science closer to students - the scientists of tomorrow. Junior high school students from the 3rd Gymnasium in Volos will have the unique opportunity to visit the ATLAS control room on 29th of March.

  7. Virtual Visit to the ATLAS Control Room by Al-Quds University

    CERN Document Server

    2014-01-01

    ATLAS virtual visit features Al-Quds University, a Palestinian university with campuses in Abu Dis and Beit Hanina-Jerusalem. As part of the "Physics Without Frontiers" project, funded by ICTP, Al-Quds is hosting a one day particle physics masterclass. During the day the students are given an introduction to particle physics, the LHC and the ATLAS Experiment, before having the chance to analyse real LHC data. This virtual visit comprises of a live tour around the ATLAS control room and the opportunity to ask questions to the ATLAS physicists.

  8. Modern digital flight control system design for VTOL aircraft

    Science.gov (United States)

    Broussard, J. R.; Berry, P. W.; Stengel, R. F.

    1979-01-01

    Methods for and results from the design and evaluation of a digital flight control system (DFCS) for a CH-47B helicopter are presented. The DFCS employed proportional-integral control logic to provide rapid, precise response to automatic or manual guidance commands while following conventional or spiral-descent approach paths. It contained altitude- and velocity-command modes, and it adapted to varying flight conditions through gain scheduling. Extensive use was made of linear systems analysis techniques. The DFCS was designed, using linear-optimal estimation and control theory, and the effects of gain scheduling are assessed by examination of closed-loop eigenvalues and time responses.

  9. Modern power systems control centers:From EMS to AEMS

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    Traditional energy management system (EMS) plays an indispensable role in control centers of electric power systems. However, it also has several shortcomings, including lack of real-time closed-loop control, unreliable functional modules, and difficult to exchange data. The electric hybrid control theory (EHCT) has been proposed as an innovative and effective means to overcome these shortcomings. This paper argues that the EHCT provides a theoretical foundation for the advanced energy management system (AEMS) that can achieve multi-objective, near-optimal, and closed-loop control of electric power grids. This paper also discusses the significance for control centers to evolve from the traditional EMS to the AEMS. Furthermore, this paper points out that the traditional EMS can be considered as an integral part of the AEMS and that the AEMS can be built upon the traditional EMS. Thus, the resources that are currently available can be fully utilized to achieve near-optimal and closed-loop control of power system operations.

  10. Modern power systems control centers: From EMS to AEMS

    Institute of Scientific and Technical Information of China (English)

    HE GuangYu; SUN YingYun; RUAN QianTu; WANG Wei; DONG ShuFeng

    2009-01-01

    Traditional energy management system (EMS) plays an indispensable role in control centers of electric power systems. However, it also has several shortcomings, including lack of real-time closed-loop control, unreliable functional modules, and difficult to exchange data. The electric hybrid control theory (EHCT) has been proposed as an innovative and effective means to overcome these shortcomings. This paper argues that the EHCT provides a theoretical foundation for the advanced energy manage-ment system (AEMS) that can achieve multi-objective, near-optimal, and closed-loop control of electric power grids. This paper also discusses the significance for control centers to evolve from the tradi-tional EMS to the AEMS. Furthermore, this paper points out that the traditional EMS can be considered as an integral part of the AEMS and that the AEMS can be built upon the traditional EMS. Thus, the re-sources that are currently available can be fully utilized to achieve near-optimal and closed-loop con-trol of power system operations.

  11. Comparing the Dimensions of Modern and Ancient Barrier Island Systems to Understand Controls on Preservation

    Science.gov (United States)

    Mulhern, J.; Johnson, C. L.; Stright, L.

    2015-12-01

    Commonly assumed to have low preservation potential, barrier islands are rarely interpreted in the rock record, and there is little consensus on the terminology and depositional models related to their interpretation. Prevalent on transgressive coastlines, the dimensions of modern barriers are used as analogs for the ancient; however, ancient examples are complicated by post-depositional processes, including thickening through amalgamation and removal by ravinement. Contrasting the dimensions of modern and ancient examples lends insight into the development and preservation of transgressive deposits, improving the ability to predict the size and distribution of barrier island sand bodies in the rock record as well as understanding the variables that control their architecture. Interpretation of barrier island deposits from the John Henry Member (Cretaceous Straight Cliffs Fm., Kaiparowits Plateau, southern Utah) motivated an investigation into both ancient and modern barrier islands. Traditional sequence stratigraphic models predict thin condensed deposition during transgression, not accounting for possible thick and laterally extensive accumulations of barrier island deposits. More recent models recognize the possible complexity and heterogeneity of transgressive deposits and the potential for barrier island accumulation. To better understand the relationship between modern and ancient barrier islands, the length (along strike), width (dip direction) and thickness (vertical) of >20 modern and >30 ancient barrier islands were compared. Ancient dimensions were gathered from the literature, while modern dimensions were aggregated from literature and a database of modern barrier islands currently being developed. Initial results suggest that ancient barrier island deposits record the motion of the shoreline during transgression. Ancient barriers are ~2-8 times wider and ~2-3 times thicker than modern islands. The dynamics of barrier island migration and sediment

  12. Human factors dimensions in the evolution of increasingly automated control rooms for near-earth satellites

    Science.gov (United States)

    Mitchell, C. M.

    1982-01-01

    The NASA-Goddard Space Flight Center is responsible for the control and ground support for all of NASA's unmanned near-earth satellites. Traditionally, each satellite had its own dedicated mission operations room. In the mid-seventies, an integration of some of these dedicated facilities was begun with the primary objective to reduce costs. In this connection, the Multi-Satellite Operations Control Center (MSOCC) was designed. MSOCC represents currently a labor intensive operation. Recently, Goddard has become increasingly aware of human factors and human-machine interface issues. A summary is provided of some of the attempts to apply human factors considerations in the design of command and control environments. Current and future activities with respect to human factors and systems design are discussed, giving attention to the allocation of tasks between human and computer, and the interface for the human-computer dialogue.

  13. Human factors dimensions in the evolution of increasingly automated control rooms for near-earth satellites

    Science.gov (United States)

    Mitchell, C. M.

    1982-01-01

    The NASA-Goddard Space Flight Center is responsible for the control and ground support for all of NASA's unmanned near-earth satellites. Traditionally, each satellite had its own dedicated mission operations room. In the mid-seventies, an integration of some of these dedicated facilities was begun with the primary objective to reduce costs. In this connection, the Multi-Satellite Operations Control Center (MSOCC) was designed. MSOCC represents currently a labor intensive operation. Recently, Goddard has become increasingly aware of human factors and human-machine interface issues. A summary is provided of some of the attempts to apply human factors considerations in the design of command and control environments. Current and future activities with respect to human factors and systems design are discussed, giving attention to the allocation of tasks between human and computer, and the interface for the human-computer dialogue.

  14. Towards a modern concept for teaching control engineering

    DEFF Research Database (Denmark)

    Niemann, Hans Henrik; Andersen, Jens Christian; Ravn, Ole

    2009-01-01

    these previous courses and athe introduction course in control theory. As a direct consequence, it is now possible to introduce and use feedback control from the first lecture. The new teaching concept has had a major effect on the exam results. In the two semesters before the changes, only 53% of the students......A new concept for teaching an introduction course in control engineering is described. The main issue is that the concept is based directly on the students’ knowledge from previous courses in math, physics and electronics. This will provid the students with a more direct and clear link between...... passed the course. In the first two semesters after the changes, 86% of the students passed the course....

  15. Adaptive Backstepping Control and Safety Analysis for Modern Fighter Aircraft

    NARCIS (Netherlands)

    Van Oort, E.R.

    2011-01-01

    There exist many examples of aircraft incidents in which the pilots have successfully used the remaining control authority over an aircraft to save the airframe and its passengers and cargo from apparently hopeless failure conditions. Unfortunately, the opposite is also true. Several accidents

  16. Archon: A modern controller for high performance astronomical CCDs

    Science.gov (United States)

    Bredthauer, Greg

    2014-08-01

    The rapid evolution of commercial FPGAs and analog ICs has enabled the development of Archon, a new modular high performance astronomical CCD controller. CCD outputs are digitized by 16-bit 100 MHz ADCs with differential AC-coupled preamplifiers. The raw data stream from an ADC can be stored in parallel with standard image data into three onboard 512 MB frame buffers. Pixel values are computed using digital correlated double sampling. At low pixel rates (ADC samples per pixel can exceed 16 bits, so an option to store 32 bits per pixel is provided. CCD clocks are generated by 14-bit 100 MHz DACs. The scripted timing core driving the clocks can generate a new target voltage for each clock every 10 ns, and the clock slew rates are individually programmable. CCD biases are derived from 16-bit DACs, are continuously monitored for voltage and current, and power up and down in a customizable sequence. Communication between the controller and a host computer occurs over a gigabit Ethernet interface (fiber or copper). A CCD configuration is specified by a simple text file. Together, these features simplify the tuning and debugging of scientific CCDs, and enable CCD-limited imaging. I present details of the controller architecture, examples of CCD tuning, and measured performance data of the controller alone (dynamic range of 108 dB at 100 kHz and 98 dB at 1 MHz) and in combination with an STA1600LN CCD.

  17. Towards a modern concept for teaching control engineering

    DEFF Research Database (Denmark)

    Niemann, Hans Henrik; Andersen, Jens Christian; Ravn, Ole

    2009-01-01

    A new concept for teaching an introduction course in control engineering is described. The main issue is that the concept is based directly on the students’ knowledge from previous courses in math, physics and electronics. This will provid the students with a more direct and clear link between...

  18. A HUMAN AUTOMATION INTERACTION CONCEPT FOR A SMALL MODULAR REACTOR CONTROL ROOM

    Energy Technology Data Exchange (ETDEWEB)

    Le Blanc, Katya; Spielman, Zach; Hill, Rachael

    2017-06-01

    Many advanced nuclear power plant (NPP) designs incorporate higher degrees of automation than the existing fleet of NPPs. Automation is being introduced or proposed in NPPs through a wide variety of systems and technologies, such as advanced displays, computer-based procedures, advanced alarm systems, and computerized operator support systems. Additionally, many new reactor concepts, both full scale and small modular reactors, are proposing increased automation and reduced staffing as part of their concept of operations. However, research consistently finds that there is a fundamental tradeoff between system performance with increased automation and reduced human performance. There is a need to address the question of how to achieve high performance and efficiency of high levels of automation without degrading human performance. One example of a new NPP concept that will utilize greater degrees of automation is the SMR concept from NuScale Power. The NuScale Power design requires 12 modular units to be operated in one single control room, which leads to a need for higher degrees of automation in the control room. Idaho National Laboratory (INL) researchers and NuScale Power human factors and operations staff are working on a collaborative project to address the human performance challenges of increased automation and to determine the principles that lead to optimal performance in highly automated systems. This paper will describe this concept in detail and will describe an experimental test of the concept. The benefits and challenges of the approach will be discussed.

  19. Procedure and information displays in advanced nuclear control rooms: experimental evaluation of an integrated design.

    Science.gov (United States)

    Chen, Yue; Gao, Qin; Song, Fei; Li, Zhizhong; Wang, Yufan

    2017-08-01

    In the main control rooms of nuclear power plants, operators frequently have to switch between procedure displays and system information displays. In this study, we proposed an operation-unit-based integrated design, which combines the two displays to facilitate the synthesis of information. We grouped actions that complete a single goal into operation units and showed these operation units on the displays of system states. In addition, we used different levels of visual salience to highlight the current unit and provided a list of execution history records. A laboratory experiment, with 42 students performing a simulated procedure to deal with unexpected high pressuriser level, was conducted to compare this design against an action-based integrated design and the existing separated-displays design. The results indicate that our operation-unit-based integrated design yields the best performance in terms of time and completion rate and helped more participants to detect unexpected system failures. Practitioner Summary: In current nuclear control rooms, operators frequently have to switch between procedure and system information displays. We developed an integrated design that incorporates procedure information into system displays. A laboratory study showed that the proposed design significantly improved participants' performance and increased the probability of detecting unexpected system failures.

  20. Advantages and Disadvantages of Physiological Assessment For Next Generation Control Room Design

    Energy Technology Data Exchange (ETDEWEB)

    Tuan Q. Tran; Ronald L. Boring; Donald D. Dudenhoeffer; Bruce P Hallbert; M. David Keller; Tessa M. Anderson

    2007-08-01

    Abstract - We propose using non-obtrusive physiological assessment (e.g., eye tracking,) to assess human information processing errors (e.g., loss of vigilance) and limitations (e.g., workload) for advanced energy systems early in the design process. This physiological approach for assessing risk will circumvent many limitations of current risk methodologies such as subjective rating (e.g., rater’s biases) and performance modeling (e.g., risk assessment is scripted and is based upon the individual modeler’s judgment). Key uses will be to evaluate (early in the design process) novel control room equipment and configurations as well as newly developed automated systems that will inevitably place a high information load on operators. The physiological risk assessment tool will allow better precision in pinpointing problematic design issues and will provide a “real-time” assessment of risk. Furthermore, this physiological approach would extend the state-of-the-art of human reliability methods from a “static” measure to more “dynamic.” This paper will discuss a broad range of the current popular online performance gauges as well as its advantages and disadvantages for use in next generation control room.

  1. Requirements for future control room and visualization features in the Web-of-Cells framework defined in the ELECTRA project

    DEFF Research Database (Denmark)

    Tornelli, Carlo; Zuelli, Roberto; Marinelli, Mattia

    2017-01-01

    This paper outlines an overview of the general requirements for the control rooms of the future power systems (2030+). The roles and activities in the future control centres will evolve with respect to the switching, dispatching and restoration functions currently active. The control centre...... operators will supervise on the power system and intervene - when necessary - thanks to the maturation and wide scale deployment of flexible controls. For the identification of control room requirements, general trends in power system evolution are considered and mainly the outcomes of the ELECTRA IRP...... project, that proposes a new Web-of-Cell (WoC) power system control architecture. Dedicated visualization features are proposed, aimed to support the control room operators activities in a WoC oriented approach. Furthermore, the work takes into account the point of view of network operators about future...

  2. Overview of Total Knee Arthroplasty and Modern Pain Control Strategies.

    Science.gov (United States)

    Lavie, Lacey Giambelluca; Fox, M Patricia; Dasa, Vinod

    2016-11-01

    Perioperative pain management of total knee arthroplasty (TKA) remains a challenge for physicians and anesthesiologists. Reducing postoperative pain is an essential component of patient satisfaction, functional outcomes, and hospital length of stay. Multimodal pain management regimens have been demonstrated to be superior to monotherapy in achieving adequate pain control, as well as an effective method of limiting side effects of analgesics. In the present investigation, we present literature published over the last year relating to new advancements in perioperative pain management for TKA. While it is widely accepted that methods including peripheral nerve blocks and local anesthetic injections are essential to pain protocols, there is still conflicting evidence over what modalities provide superior relief. The incorporation of cryoneurolysis preoperatively is a new modality which has been incorporated and has been shown to improve pain control in patients undergoing TKA.

  3. Control of environmental impact with modern chemical technology

    Science.gov (United States)

    Hocking, Martin B.

    1986-03-01

    Here are assembled representative excerpts from a new text in applied chemistry. They illustrate the well-referenced treatment of industrial processes that are here considered with their related emission control problems and solutions. A brief account of general aspects of the industry is followed by surveys of the significance and technical aspects of air and water pollution chemistry. Consideration is given to emission avoidance or containment, waste treatment, and waste disposal options as they relate to both of these environmental areas. Details of salt recovery and the products of brine electrolysis plus environmental aspects of these operations are treated as examples of some of the processes discussed. Also covered are fertilizer constituent preparation, formulation, and use with consideration of the large-scale effects of each of these activities. Detailed reference is made to the chemical technology and emission control aspects of the pulp and paper industry and refinery operations. Throughout, integral process changes and waste recycling practices are directly related to emission control aspects of each process in a way to be useful to the student and professional alike. These excerpts are extracted from one of the first, single volume accounts to take this unified approach to the subject.

  4. Malfunction analysis response system (MARS) for nuclear power plants control rooms

    Energy Technology Data Exchange (ETDEWEB)

    Peters, F.; Rossmann, D.L.

    1984-01-01

    Whenever the need for the safe and reliable operation of a complex system exists, a major requirement for success is the actions of the people involved. This is especially true when a time-critical response is required. In this context, the operation of a nuclear power plant is exemplary. Lessons from the Three Mile Island-2 incident show that insufficient attention was paid to the man/machine interface. Since that time, considerable effort has been directed by the nuclear industry toward the improvement of control room instrumentation, emergency operating procedures, and operator training. The improvement of the safety of nuclear power plants through the reduction of operator errors is discussed. The nuclear power plant operator's diagnostic role is analogous to that of a flight controller for a manned space flight mission. Both must be able to quickly understand and integrate large quantities of information on current system operation with background data on system design and performance.

  5. Review of advanced control rooms: Methodological considerations for the use of HFE guidelines

    Energy Technology Data Exchange (ETDEWEB)

    O`Hara, J.M.

    1994-03-01

    Control rooms for advanced nuclear power plants use advanced human-system interface (HSI) technologies that may have significant implications for plant safety in that they will affect the operator`s overall role in the system and the ways in which operators interact with the system. The US Nuclear Regulatory Commission (NRC) reviews HSIs to ensure that they are designed to accepted human factors engineering (HFE) principles. The principal review guidance, however, is more than ten-years old (US NRC, 1981). Accordingly, an Advanced HSI Design Review Guideline (DRG) was developed to provide criteria for these reviews. The DRG contains seven major sections: Information Display, User-System Interaction, Process Control and Input Devices, Alarms, Analysis and Decision Aids, Inter-Personnel Communication, and Workplace Design (see O`Hara & Brown, 1993). The purpose of this paper is to describe the methodology for DRG use.

  6. Virtual Visit to the ATLAS Control Room by Institute of Nuclear Physics, Cracow, Poland

    CERN Multimedia

    ATLAS Experiment

    2012-01-01

    The 12 Festival of Science "Theory-knowledge-experience...". Fest will be located on the traditional Main Square, which is visited by thousands of citizens and tourists. Institute of Nuclear Physics as usual participates in this annual event. Our visitors will learn the secrets of the CERN experiments on the Large Hadron Collider - ATLAS, LHCb, ALICE, CMS, find out more about the Higgs particles, antimatter quark-gluon plasma (beeing guided by our scientists and PhD students). One of the attractions will be ATLAS Control Room Virtual Visit. Visiting people will have an opportunity to see how ATLAS is controlled and operated to collect its exciting data and ask questions to scientists and engineers involved in LHC program at CERN. Institute of Nuclear Physics has prepared also several interactive demonstrations of Atomic Force Microscopy, Magnetic Resonance, Hadron Therapy and Crystal Physics. The Institute of Nuclear Physics of the Polish Academy of Sciences carries out basic and applied research in physics, ...

  7. Experimental and numerical comparison of absorption optimization in small rooms

    DEFF Research Database (Denmark)

    Wincentz, Jakob Nygård; Garcia, Julian Martinez-Villalba; Jeong, Cheol-Ho

    2016-01-01

    A vast majority of modern music is recorded and produced in small control room environments of volumes of around 50 m3 . Several problems occur when controlling the room acoustics of such small spaces. First, the room modes will produce strong peaks and dips particularly at lower frequencies, and......, boundary conditions, and phase information providing accuracy at low frequencies. Good agreements are found between measurements and simulations, confirming that FEM can be used as a design tool for optimizing absorption and acoustic parameters in small rooms......A vast majority of modern music is recorded and produced in small control room environments of volumes of around 50 m3 . Several problems occur when controlling the room acoustics of such small spaces. First, the room modes will produce strong peaks and dips particularly at lower frequencies...... the Schroeder frequency. This project investigates experimentally changes in the room acoustic parameters by altering the positioning and orientation of porous materials in a small room, which are compared with finite element method (FEM) simulations. FEM is able to take into account the exact room geometry...

  8. Modernization Of Electrical Installation By Using Wireless Remote Control

    Directory of Open Access Journals (Sweden)

    Mawlood M Al – Hamad

    2013-05-01

    Full Text Available Great benefits can be achieved by using wireless remote control in electrical wiring systems of buildings.     Probably the main advantage of this application is the drastic saving in wiring installations, which in turn will give higher reliability, safety and economy.     The idea of this application can be summarized in the following explanation. '' Instead off connecting each point of electrical system to individual switch by wires, a remote receiver can be situated in a place near to the point. The transmitter is used to operate the point remotely. The mains are connected to the receiver which will connect or disconnect the load as required. Many points can be connected to one receiver and can be operated by one or more transmitter.

  9. Controlled Acoustic Bass System (CABS) A Method to Achieve Uniform Sound Field Distribution at Low Frequencies in Rectangular Rooms

    DEFF Research Database (Denmark)

    Celestinos, Adrian; Nielsen, Sofus Birkedal

    2008-01-01

    The sound field produced by loudspeakers at low frequencies in small- and medium-size rectangular listening rooms is highly nonuniform due to the multiple reflections and diffractions of sound on the walls and different objects in the room. A new method, called controlled acoustic bass system (CABS......), is introduced. The system utilizes front loudspeakers and extra loudspeakers on the opposite wall of the room processed to cancel out the rear-wall reflections, which effectively conveys a more uniform sound field. The system works in the time domain and presents good performance over the loudspeaker low...

  10. Future Vision for Instrumentation, Information and Control Modernization

    Energy Technology Data Exchange (ETDEWEB)

    Ken D. Thomas

    2012-05-01

    A Future Vision of a transformed nuclear plant operating model based on an integrated digital environment has been developed as part of the Advanced Instrumentation, Information, and Control (II&C) research pathway, under the Light Water Reactor (LWR) Sustainability Program. This is a research and development program sponsored by the U.S. Department of Energy (DOE), performed in close collaboration with the nuclear utility industry, to provide the technical foundations for licensing and managing the long-term, safe and economical operation of current nuclear power plants. II&C has been identified as a potential life-limiting issue for the domestic LWR fleet in addressing the reliability and aging concerns of the legacy systems in service today. The Future Vision is based on a digital architecture that encompasses all aspects of plant operations and support, integrating plant systems, plant work processes, and plant workers in a seamless digital environment to enhance nuclear safety, increase productivity, and improve overall plant performance. Pilot projects are being conducted as the means for industry to gain confidence in these new technologies for use in nuclear plant work activities. The pilot projects introduce new digital technologies into the nuclear plant operating environment at host operating plants to demonstrate and validate them for production usage. In turn, the pilot project technologies serve as the stepping stones to the eventual seamless digital environment as described in the Future Vision. Initial project results confirm that the technologies can address provide substantial efficiency and human performance benefits while resolving the reliability and aging concerns.

  11. Modern control concepts in hydrology. [parameter identification in adaptive stochastic control approach

    Science.gov (United States)

    Duong, N.; Winn, C. B.; Johnson, G. R.

    1975-01-01

    Two approaches to an identification problem in hydrology are presented, based upon concepts from modern control and estimation theory. The first approach treats the identification of unknown parameters in a hydrologic system subject to noisy inputs as an adaptive linear stochastic control problem; the second approach alters the model equation to account for the random part in the inputs, and then uses a nonlinear estimation scheme to estimate the unknown parameters. Both approaches use state-space concepts. The identification schemes are sequential and adaptive and can handle either time-invariant or time-dependent parameters. They are used to identify parameters in the Prasad model of rainfall-runoff. The results obtained are encouraging and confirm the results from two previous studies; the first using numerical integration of the model equation along with a trial-and-error procedure, and the second using a quasi-linearization technique. The proposed approaches offer a systematic way of analyzing the rainfall-runoff process when the input data are imbedded in noise.

  12. Modeling Human Error Mechanism for Soft Control in Advanced Control Rooms (ACRs)

    Energy Technology Data Exchange (ETDEWEB)

    Aljneibi, Hanan Salah Ali [Khalifa Univ., Abu Dhabi (United Arab Emirates); Ha, Jun Su; Kang, Seongkeun; Seong, Poong Hyun [KAIST, Daejeon (Korea, Republic of)

    2015-10-15

    To achieve the switch from conventional analog-based design to digital design in ACRs, a large number of manual operating controls and switches have to be replaced by a few common multi-function devices which is called soft control system. The soft controls in APR-1400 ACRs are classified into safety-grade and non-safety-grade soft controls; each was designed using different and independent input devices in ACRs. The operations using soft controls require operators to perform new tasks which were not necessary in conventional controls such as navigating computerized displays to monitor plant information and control devices. These kinds of computerized displays and soft controls may make operations more convenient but they might cause new types of human error. In this study the human error mechanism during the soft controls is studied and modeled to be used for analysis and enhancement of human performance (or human errors) during NPP operation. The developed model would contribute to a lot of applications to improve human performance (or reduce human errors), HMI designs, and operators' training program in ACRs. The developed model of human error mechanism for the soft control is based on assumptions that a human operator has certain amount of capacity in cognitive resources and if resources required by operating tasks are greater than resources invested by the operator, human error (or poor human performance) is likely to occur (especially in 'slip'); good HMI (Human-machine Interface) design decreases the required resources; operator's skillfulness decreases the required resources; and high vigilance increases the invested resources. In this study the human error mechanism during the soft controls is studied and modeled to be used for analysis and enhancement of human performance (or reduction of human errors) during NPP operation.

  13. Copper Selenide Nanosnakes: Bovine Serum Albumin-Assisted Room Temperature Controllable Synthesis and Characterization

    Science.gov (United States)

    Huang, Peng; Kong, Yifei; Li, Zhiming; Gao, Feng; Cui, Daxiang

    2010-06-01

    Herein we firstly reported a simple, environment-friendly, controllable synthetic method of CuSe nanosnakes at room temperature using copper salts and sodium selenosulfate as the reactants, and bovine serum albumin (BSA) as foaming agent. As the amounts of selenide ions (Se2-) released from Na2SeSO3 in the solution increased, the cubic and snake-like CuSe nanostructures were formed gradually, the cubic nanostructures were captured by the CuSe nanosnakes, the CuSe nanosnakes grew wider and longer as the reaction time increased. Finally, the cubic CuSe nanostructures were completely replaced by BSA-CuSe nanosnakes. The prepared BSA-CuSe nanosnakes exhibited enhanced biocompatibility than the CuSe nanocrystals, which highly suggest that as-prepared BSA-CuSe nanosnakes have great potentials in applications such as biomedical engineering.

  14. Copper Selenide Nanosnakes: Bovine Serum Albumin-Assisted Room Temperature Controllable Synthesis and Characterization

    Directory of Open Access Journals (Sweden)

    Huang Peng

    2010-01-01

    Full Text Available Abstract Herein we firstly reported a simple, environment-friendly, controllable synthetic method of CuSe nanosnakes at room temperature using copper salts and sodium selenosulfate as the reactants, and bovine serum albumin (BSA as foaming agent. As the amounts of selenide ions (Se2− released from Na2SeSO3 in the solution increased, the cubic and snake-like CuSe nanostructures were formed gradually, the cubic nanostructures were captured by the CuSe nanosnakes, the CuSe nanosnakes grew wider and longer as the reaction time increased. Finally, the cubic CuSe nanostructures were completely replaced by BSA–CuSe nanosnakes. The prepared BSA–CuSe nanosnakes exhibited enhanced biocompatibility than the CuSe nanocrystals, which highly suggest that as-prepared BSA–CuSe nanosnakes have great potentials in applications such as biomedical engineering.

  15. Intelligent software system for the advanced control room of a nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Soon Heung; Choi, Seong Soo; Park, Jin Kyun; Heo, Gyung Young [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of); Kim, Han Gon [Korea Electric Power Research Institute, Taejon (Korea, Republic of)

    1997-12-31

    The intelligent software system for nuclear power plants (NPPs) has been conceptually designed in this study. Its design goals are to operate NPPs in an improved manner and to support operators` cognitive takes. It consists of six major modules such as {sup I}nformation Processing,{sup {sup A}}larm Processing,{sup {sup P}}rocedure Tracking,{sup {sup P}}erformance Diagnosis,{sup a}nd {sup E}vent Diagnosis{sup m}odules for operators and {sup M}alfunction Diagnosis{sup m}odule for maintenance personnel. Most of the modules have been developed for several years and the others are under development. After the completion of development, they will be combined into one system that would be main parts of advanced control rooms in NPPs. 5 refs., 4 figs. (Author)

  16. Virtual Visit to the ATLAS Control Room by Natural History Museum, London

    CERN Multimedia

    ATLAS Experiment

    2012-01-01

    Nature Live is a programme of daily events which take place at the Natural History Museum, London. Nature Live brings together scientists and visitors to explore, discover and discuss the natural world and our place within it. In each event visitors get the chance to meet our scientists, see the specimens they study and ask lots of questions. Today Nature Live will feature a live link to the LHC control room at CERN. This will give visitors the amazing opportunity to ask questions to the physicists involved about the Large Hadron Collider experiments, Higgs particles and antimatter. As well as to discover how scientists at the Museum and at CERN are all looking back through deep time to answer those big questions on the origins of life, the universe and everything. http://atlas-live-virtual-visit.web.cern.ch/atlas-live-virtual-visit/2012/London_NatureLive-2012.html

  17. Implementation of Software Tools for Hybrid Control Rooms in the Human Systems Simulation Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Jokstad, Håkon [Halden Reactor Project, Halden (Norway); Berntsson, Olof [Halden Reactor Project, Halden (Norway); McDonald, Robert [Halden Reactor Project, Halden (Norway); Boring, Ronald [Idaho National Lab. (INL), Idaho Falls, ID (United States); Hallbert, Bruce [Idaho National Lab. (INL), Idaho Falls, ID (United States); Fitzgerald, Kirk [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-11-01

    The Institute for Energy Technology (IFE) and Idaho National Laboratory have designed, implemented, tested and installed a functioning prototype of a set of large screen overview and procedure support displays for the Generic Pressurized Water Reactor (GPWR) simulator in the U.S. Department of Energy’s Human Systems Simulation Laboratory. The overview display is based on IFE’s extensive experiences with large screen overview displays in the Halden Man-Machine Laboratory (HAMMLAB), and presents the main control room indicators on a combined three-screen display. The procedure support displays are designed and implemented to provide a compact but still comprehensive overview of the relevant process measurements and indicators to support operators' good situational awareness during the performance of various types of procedures and plant conditions.

  18. Virtual Visit to the ATLAS Control Room by Europe Day Symposium

    CERN Multimedia

    2013-01-01

    EUROPE DAY 2013: A Symposium Examining Canada/European Scientific Collaboration On May 9 2013. Canadians in Vancouver, British Columbia, will be gathering to enrich their understanding of scientific collaboration between Canada and Europe using CERN and its recent discovery of the Higgs boson as a framework for a symposium celebrating Europe Day. Canadians have been involved in nearly every aspect of the Large Hadron Collider accelerator and the ATLAS particle-physics detector. ATLAS-Canada spokesperson Rob McPherson will be addressing the symposium participants and talking about the multi-national effort that led to the Higgs breakthrough; his presentation will include a live virtual visit to the ATLAS control room at CERN. The event is hosted by TRIUMF, Canada`s national laboratory for particle and nuclear physics. http://www.europeanfestival.ca/europe-day

  19. Virtual Visit to the ATLAS Control Room by QuarkNet program in Portland

    CERN Multimedia

    2013-01-01

    The LHC fellows of the U.S. QuarkNet program will hold a workshop "Real LHC Data for the Classroom" for teachers using elements of the ATLAS masterclass on July 13, 2013. The workshop is part of the Summer 2013 Meeting of the American Association of Physics Teachers. In the workshop, teachers are introduced to particle physics, the ATLAS experiment, and ways to use actual data from the Large Hadron Collider at CERN to help their students understand fundamental physics. One of the highlights of this one-day workshop is an ATLAS Virtual Visit, in which the teachers connect by videoconference with the ATLAS control room. In the videoconferecne, the participants will be able to to ask questions of and have discussions with an ATLAS physicist.

  20. Near-room-temperature refrigeration through voltage-controlled entropy change in multiferroics

    Science.gov (United States)

    Binek, Ch.; Burobina, V.

    2013-01-01

    Composite materials with large magnetoelectric effect are proposed for application in advanced near-room-temperature refrigeration. The key innovation rests on utilizing the magnetocaloric effect in zero applied magnetic fields. This approach promises sizable isothermal entropy change and virtually temperature-independent refrigerant capacity through pure voltage-control. It is in sharp contrast with the conventional method of exploiting the magnetocaloric effect through applied magnetic fields. We outline the thermodynamics and estimate an isothermal entropy change specifically for the La0.7Sr0.3MnO3/Pb(Mg1/3Nb2/3)O3-PbTiO3(001) two-phase composite material. Finally, we propose structural variations of two-phase composites, which help in overcoming the challenging task of producing nanostructured material in macroscopic quantities.

  1. Control of room-temperature defect-mediated ferromagnetism in VO{sub 2} films

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Tsung-Han, E-mail: tyang3@ncsu.edu [NSF Center for Advanced Materials and Smart Structures, Department of Materials Science and Engineering, North Carolina State University, Raleigh, NC 27695-7907 (United States); Nori, Sudhakar; Mal, Siddhartha; Narayan, Jagdish [NSF Center for Advanced Materials and Smart Structures, Department of Materials Science and Engineering, North Carolina State University, Raleigh, NC 27695-7907 (United States)

    2011-09-15

    We report interesting ferromagnetic properties and their control in a vanadium-based oxide system driven by stoichiometric defects. Vanadium oxide (VO{sub 2}) thin films were grown on c-plane sapphire substrates by a pulsed laser deposition technique under different ambient conditions. The ferromagnetism of the epitaxial VO{sub 2} films can be switched on and off by altering the cooling ambient parameters. In addition, the saturated magnetic moments and coercivity of the VO{sub 2} films were found to be a function of the oxygen partial pressure during the growth process. The room-temperature ferromagnetic properties of VO{sub 2} films were correlated with the nature of the microstructure and the growth parameters. The origin of the induced magnetic properties are qualitatively understood to stem from intrinsic structural and stoichiometric defects.

  2. Virtual Visit to the ATLAS Control Room by 1st and 3rd Lyceums in Chios

    CERN Multimedia

    2013-01-01

    High school students from the 1st and 3rd Lyceums of Chios, Greece, will be visiting the control room of ATLAS to discuss the latest results on the Higgs search, LHC’s first long shutdown and what the future holds for the ATLAS experiment. This visit takes place in the context of a Masterclass where students will learn how to analyse real events from the LHC with the use of the HYPATIA online applet based on educational scenarios from the Discover the COSMOS portal. This full-day activity is organized by the University of Athens, the University of the Aegean, Ellinogermaniki Agogi and the Chios Physical Society in the framework of the Open Discovery Space EU project.

  3. Verification and validation of human factors issues in control room design and upgrades

    Energy Technology Data Exchange (ETDEWEB)

    Green, M.; Collier, S. [Inst. for Energiteknikk, Halden (Norway). OECD Halden Reactor Project

    1999-12-01

    Systems, facilities and equipment are periodically updated during a power plant's lifetime. This has human factors implications, especially if the central control room is involved. Human factors work may therefore be required. There is an extensive literature on human factors itself, but not so much on how it is verified and validated. Therefore, HRP and the Swedish Nuclear Power Inspectorate commissioned a study. The objective was to review the literature and establish a knowledge base on verification and validation (V and V) of human factors issues. The report first discusses verification and validation as applied to human factors work. It describes a design process and the typical human factors topics involved. It then presents a generic method for V and V of human factors. This is built on a review of standards, guidelines and other references given in an annotated bibliography. The method is illustrated by application to some human factors topics.

  4. Virtual Visit to the ATLAS Control Room by the University of Genova

    CERN Multimedia

    ATLAS Experiment

    2012-01-01

    The ATLAS Virtual Visit is included in the program of the Course in Particle and Nuclear Experimental Physics at the Physics Department of the Genova University. Students are introduced to experimental techniques and instrumentation and run few experiences in the laboratory. Besides that, they visit the Department groups that are involved both in Nuclear or High Energy Particle physics experiments. In this context, the ATLAS team will open them the doors to laboratory where ~1/3 of the Pixel detector has been built and where we are currently assembling and qualifying part of the electrical services and modules for the Insertable B layer (IBL) that will be installed in 2014 in ATLAS. Students will be introduced to LHC, ATLAS and the physics program before having the possibility to meet ATLAS physicists in ATLAS control room. http://atlas-live-virtual-visit.web.cern.ch/atlas-live-virtual-visit/2012/Genova-2012.html

  5. Virtual Visit to the ATLAS Control Room by the Genova University

    CERN Multimedia

    2013-01-01

    The ATLAS Virtual Visit is included in the program of the Course in Particle and Nuclear Experimental Physics at the Physics Department of the Genova University. Students are introduced to experimental techniques and instrumentation and run few experiences in the laboratory. Besides that, they visit the Department groups that are involved both in Nuclear or High Energy Particle physics experiments. In this context, the ATLAS team will open them the doors to laboratory where ~1/3 of the Pixel detector has been built and where we are currently assembling and qualifying part of the electrical services and modules for the Insertable B layer (IBL) that will be installed in 2014 in ATLAS. Students will be introduced to LHC, ATLAS and the physics program before having the possibility to meet ATLAS physicists in ATLAS control room. http://atlas-live-virtual-visit.web.cern.ch/atlas-live-virtual-visit/2013/Genova-2013_2.html

  6. Virtual Visit to the ATLAS Control Room by the Genova University

    CERN Multimedia

    2013-01-01

    The ATLAS Virtual Visit is included in the program of the Course in Particle and Nuclear Experimental Physics at the Physics Department of the Genova University. Students are introduced to experimental techniques and instrumentation and run few experiences in the laboratory. Besides that, they visit the Department groups that are involved both in Nuclear or High Energy Particle physics experiments. In this context, the ATLAS team will open them the doors to laboratory where ~1/3 of the Pixel detector has been built and where we are currently assembling and qualifying part of the electrical services and modules for the Insertable B layer (IBL) that will be installed in 2014 in ATLAS. Students will be introduced to LHC, ATLAS and the physics program before having the possibility to meet ATLAS physicists in ATLAS control room. http://atlas-live-virtual-visit.web.cern.ch/atlas-live-virtual-visit/2013/Genova-2013_1.html

  7. Virtual Visit to the ATLAS Control Room by High Schools from Greece & Cyprus

    CERN Multimedia

    2014-01-01

    The subatomic journey to Nobel Prize experiments at CERN continues - this time in Greece and Cyprus. More than 600 high-schoolers from 12 schools in seven different locations across the two countries will have the unique opportunity to visit the control room of the ATLAS experiment to interact live with a Greek scientist involved in the search for the Higgs Boson and learn what it takes for CERN scientists to keep pushing the boundaries of our understanding of the origins of the Universe at the world`s largest particle physics laboratory. This international-level virtual visit has been supported by the Open Discovery Space and Inspiring Science Education EU projects that aim to help science teachers find innovative ways to make their teaching of physics and science more inspirational, attractive and relevant to students` lives.

  8. Automation inflicted differences on operator performance in nuclear power plant control rooms

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, Jonas; Osvalder, A.L. [Chalmers Univ. of Technology, Dept. of Product and Producton Development (Sweden)

    2007-03-15

    Today it is possible to automate almost any function in a human-machine system. Therefore it is important to find a balance between automation level and the prerequisites for the operator to maintain safe operation. Different human factors evaluation methods can be used to find differences between automatic and manual operations that have an effect on operator performance; e.g. Predictive Human Error Analysis (PHEA), NASA Task Load Index (NASA-TLX), Halden Questionnaire, and Human Error Assessment and Reduction Technique (HEART). Results from an empirical study concerning automation levels, made at Ringhals power plant, showed that factors as time pressure and criticality of the work situation influenced the operator's performance and mental workload more than differences in level of automation. The results indicate that the operator's attention strategies differ between the manual and automatic sequences. Independently of level of automation, it is essential that the operator retains control and situational understanding. When performing a manual task, the operator is 'closer' to the process and in control with sufficient situational understanding. When the level of automation increases, the demands on information presentation increase to ensure safe plant operation. The need for control can be met by introducing 'control gates' where the operator has to accept that the automatic procedures are continuing as expected. Situational understanding can be established by clear information about process status and by continuous feedback. A conclusion of the study was that a collaborative control room environment is important. Rather than allocating functions to either the operator or the system, a complementary strategy should be used. Key parameters to consider when planning the work in the control room are time constraints and task criticality and how they affect the performance of the joint cognitive system.However, the examined working

  9. Interim results of the study of control room crew staffing for advanced passive reactor plants

    Energy Technology Data Exchange (ETDEWEB)

    Hallbert, B.P.; Sebok, A.; Haugset, K. [OECD Halden Reactor Project (Norway)

    1996-03-01

    Differences in the ways in which vendors expect the operations staff to interact with advanced passive plants by vendors have led to a need for reconsideration of the minimum shift staffing requirements of licensed Reactor Operators and Senior Reactor Operators contained in current federal regulations (i.e., 10 CFR 50.54(m)). A research project is being carried out to evaluate the impact(s) of advanced passive plant design and staffing of control room crews on operator and team performance. The purpose of the project is to contribute to the understanding of potential safety issues and provide data to support the development of design review guidance. Two factors are being evaluated across a range of plant operating conditions: control room crew staffing; and characteristics of the operating facility itself, whether it employs conventional or advanced, passive features. This paper presents the results of the first phase of the study conducted at the Loviisa nuclear power station earlier this year. Loviisa served as the conventional plant in this study. Data collection from four crews were collected from a series of design basis scenarios, each crew serving in either a normal or minimum staffing configuration. Results of data analyses show that crews participating in the minimum shift staffing configuration experienced significantly higher workload, had lower situation awareness, demonstrated significantly less effective team performance, and performed more poorly as a crew than the crews participating in the normal shift staffing configuration. The baseline data on crew configurations from the conventional plant setting will be compared with similar data to be collected from the advanced plant setting, and a report prepared providing the results of the entire study.

  10. Construction of Modern Comprehensive Training Rooms for International Settlement in Higher Vocational Colleges%高职院校构建现代化国际结算综合实训室的路径探究

    Institute of Scientific and Technical Information of China (English)

    王晓东

    2013-01-01

    随着国际结算发展速度的加快,高职院校构建现代化国际结算综合实训室也被提上日程.实训室的建立,有利于学生更好地掌握国际结算的基础知识、突出学生在国际结算教学中的主体地位、提高学生就业能力,使学生更好地适应现代社会.文章运用规范的分析方法,研究结果认为,构建国际结算综合实训室,应从引入商业银行的产品业务创新实训模式、搭建师生互动实训平台、采用实际案例的实训方案、尝试实行双语实训、加强实训师资队伍的建设等方面进行.%With the speed up of international settlement,the construction of modern comprehensive training rooms in higher vocational colleges for international settlement has been put on the agenda.The construction of the training rooms can help students better understand the basic knowledge of international settlement,improve students' employment ability,and enable students to better adapt to the modern society.It is pointed in this paper,after normative analysis,that in the construction of the modern comprehensive training rooms for international settlement integrated training room,the commercial bank business innovation training mode should be introduced,interactive training platforms should be built,bilingual training should be adopted,and the construction of the faculty-team should be strengthened.

  11. Room transfers and the risk of delirium incidence amongst hospitalized elderly medical patients: a case-control study.

    Science.gov (United States)

    Goldberg, Amanda; Straus, Sharon E; Hamid, Jemila S; Wong, Camilla L

    2015-06-25

    Room transfers are suspected to promote the development of delirium in hospitalized elderly patients, but no studies have systematically examined the relationship between room transfers and delirium incidence. We used a case-control study to determine if the number of room transfers per patient days is associated with an increased incidence of delirium amongst hospitalized elderly medical patients, controlling for baseline risk factors. We included patients 70 years of age or older who were admitted to the internal medicine or geriatric medicine services at St. Michael's Hospital between October 2009 and September 2010 for more than 24 h. The cases consisted of patients who developed delirium during the first week of hospital stay. The controls consisted of patients who did not develop delirium during the first week of hospital stay. Patients with evidence of delirium at admission were excluded from the analysis. A multivariable logistic regression model was used to determine the relationship between room transfers and delirium development within the first week of hospital stay. 994 patients were included in the study, of which 126 developed delirium during the first week of hospital stay. Using a multivariable logistic regression model which controlled for age, gender, cognitive impairment, vision impairment, dehydration, and severe illness, room transfers per patient days were associated with delirium incidence (OR: 9.69, 95 % CI (6.20 to15.16), P patient days is associated with an increased incidence of delirium amongst hospitalized elderly medical patients. This is an exploratory analysis and needs confirmation with larger studies.

  12. Experiences in the computerized control rooms design for Nuclear Power Plants; Experiencias en el diseno de salas de control computarizadas para centrales nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Moyano de la Heras, N.; Fernandez Illobre, L.; Valdivia Martin, C.

    2010-07-01

    This paper presents Tecnatom experiences obtained during the control rooms design for the Fuming and Fangjiasham Nuclear Power Plants (CPR type). These are two different locations where two pressurized water reactors, with three loops each one, will be installed.

  13. On Some Control Structures in Hellenistic Greek: A Comparison with Classical and Modern Greek

    Directory of Open Access Journals (Sweden)

    Brian D. Joseph

    2002-01-01

    Full Text Available Control Structures in Ancient Greek typically involved infinitival complementation while in Modern Greek, finite complementation is the rule. Hellenistic Greek provides an interesting "way-station" between these two types of complementation, inasmuch as it is both chronologically and structurally transitional. In this contribution to the historical syntax of Greek, an analysis is offered of control structures in Hellenistic Greek, tracing the transition from the Ancient Greek type to the Modern Greek type. Based on the evidence of these three stages of Greek and the developments that the language shows with regard to innovations in the form and properties of control structures, an argument is put forth in support of the view that control is not a purely syntactic phenomenon but rather derives from the lexical semantics of the predicates involved.

  14. Using virtual reality to support multi-participant human-centered design processes for control room design

    Energy Technology Data Exchange (ETDEWEB)

    Louka, M. N.; Gustavsen, M. A.; Edvardsen, S. T. [OECD Halden Reactor Project, Inst. for Energy Technology, PO Box 173, NO-1751 Halden (Norway)

    2006-07-01

    We present an overview of a method of applying interactive 3D visualization techniques to support control room design activities, and summarize studies that supports it. In particular, we describe the software tools that we have developed and how these support a human-centered design (HCD) work-flow. We present some lessons learnt from using our tools in control room design projects, and outline our plans for extending the scope of our approach to support concurrent design and later phases of a plant's life-cycle. (authors)

  15. Operating Room Time Savings with the Use of Splint Packs: A Randomized Controlled Trial

    Directory of Open Access Journals (Sweden)

    Tyler Gonzalez

    2016-01-01

    Full Text Available Background: The most expensive variable in the operating room (OR is time. Lean Process Management is being used in the medical field to improve efficiency in the OR. Streamlining individual processes within the OR is crucial to a comprehensive time saving and cost-cutting health care strategy. At our institution, one hour of OR time costs approximately $500, exclusive of supply and personnel costs. Commercially prepared splint packs (SP contain all components necessary for plaster-of-Paris short-leg splint application and have the potential to decrease splint application time and overall costs by making it a more lean process. We conducted a randomized controlled trial comparing OR time savings between SP use and bulk supply (BS splint application. Methods: Fifty consecutive adult operative patients on whom post-operative short-leg splint immobilization was indicated were randomized to either a control group using BS or an experimental group using SP. One orthopaedic surgeon (EMB prepared and applied all of the splints in a standardized fashion. Retrieval time, preparation time, splint application time, and total splinting time for both groups were measured and statistically analyzed. Results: The retrieval time, preparation time and total splinting time were significantly less (p

  16. Room temperature alcohol sensing by oxygen vacancy controlled TiO{sub 2} nanotube array

    Energy Technology Data Exchange (ETDEWEB)

    Hazra, A.; Dutta, K.; Bhowmik, B.; Bhattacharyya, P., E-mail: pb-etc-besu@yahoo.com [Nano-Thin Films and Solid State Gas Sensor Devices Laboratory, Department of Electronics and Telecommunication Engineering, Indian Institute of Engineering Science and Technology (IIEST), Shibpur, Howrah (India); Chattopadhyay, P. P. [Department of Metallurgy and Materials Engineering, Indian Institute of Engineering Science and Technology (IIEST), Shibpur, Howrah (India)

    2014-08-25

    Oxygen vacancy (OV) controlled TiO{sub 2} nanotubes, having diameters of 50–70 nm and lengths of 200–250 nm, were synthesized by electrochemical anodization in the mixed electrolyte comprising NH{sub 4}F and ethylene glycol with selective H{sub 2}O content. The structural evolution of TiO{sub 2} nanoforms has been studied by field emission scanning electron microscopy. Variation in the formation of OVs with the variation of the structure of TiO{sub 2} nanoforms has been evaluated by photoluminescence and X-ray photoelectron spectroscopy. The sensor characteristics were correlated to the variation of the amount of induced OVs in the nanotubes. The efficient room temperature sensing achieved by the control of OVs of TiO{sub 2} nanotube array has paved the way for developing fast responding alcohol sensor with corresponding response magnitude of 60.2%, 45.3%, and 36.5% towards methanol, ethanol, and 2-propanol, respectively.

  17. Defect control in room temperature deposited cadmium sulfide thin films by pulsed laser deposition

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez-Como, N. [Department of Materials Science and Engineering, University of Texas at Dallas, Richardson, TX, 75080 (United States); Martinez-Landeros, V. [Department of Materials Science and Engineering, University of Texas at Dallas, Richardson, TX, 75080 (United States); Centro de Investigación en Materiales Avanzados, Monterrey, Nuevo Leon, 66600, México (Mexico); Mejia, I. [Department of Materials Science and Engineering, University of Texas at Dallas, Richardson, TX, 75080 (United States); Aguirre-Tostado, F.S. [Centro de Investigación en Materiales Avanzados, Monterrey, Nuevo Leon, 66600, México (Mexico); Nascimento, C.D.; Azevedo, G. de M; Krug, C. [Instituto de Física, Universidade Federal do Rio Grande do Sul, Porto Alegre, 91509-900 (Brazil); Quevedo-Lopez, M.A., E-mail: mquevedo@utdallas.edu [Department of Materials Science and Engineering, University of Texas at Dallas, Richardson, TX, 75080 (United States)

    2014-01-01

    The control of defects in cadmium sulfide thin films and its impact on the resulting CdS optical and electrical characteristics are studied. Sulfur vacancies and cadmium interstitial concentrations in the CdS films are controlled using the ambient pressure during pulsed laser deposition. CdS film resistivities ranging from 10{sup −1} to 10{sup 4} Ω-cm are achieved. Hall Effect measurements show that the carrier concentration ranges from 10{sup 19} to 10{sup 13} cm{sup −3} and is responsible for the observed resistivity variation. Hall mobility varies from 2 to 12 cm{sup 2}/V-s for the same pressure regime. Although the energy bandgap remains unaffected (∼ 2.42 eV), the optical transmittance is reduced due to the increase of defects in the CdS films. Rutherford back scattering spectroscopy shows the dependence of the CdS films stoichiometry with deposition pressure. The presence of CdS defects is attributed to more energetic species reaching the substrate, inducing surface damage in the CdS films during pulsed laser deposition. - Highlights: • CdS thin films deposited by pulsed laser deposition at room temperature. • The optical, electrical and structural properties were evaluated. • Carrier concentration ranged from 10{sup 19} to 10{sup 13} cm{sup −3}. • The chemical composition was studied by Rutherford back scattering. • The density of sulfur vacancies and cadmium interstitial was varied.

  18. Measurement, evaluation and control of the microclimate in rooms for weaned piglets

    NARCIS (Netherlands)

    Wagenberg, van A.V.

    2005-01-01

    The Animal Occupied Zone (AOZ), or the microclimate, in a room for weaned piglets is roughly the zone between 0 and 50 cm above the floor of the pen. It is distinguished from the macroclimate, which is the average climate of a pig room. The ability to create and maintain an optimal climate in the AO

  19. Long-Term Instrumentation, Information, and Control Systems (II&C) Modernization Future Vision and Strategy

    Energy Technology Data Exchange (ETDEWEB)

    Kenneth Thomas; Bruce Hallbert

    2013-02-01

    Life extension beyond 60 years for the U.S operating nuclear fleet requires that instrumentation and control (I&C) systems be upgraded to address aging and reliability concerns. It is impractical for the legacy systems based on 1970’s vintage technology operate over this extended time period. Indeed, utilities have successfully engaged in such replacements when dictated by these operational concerns. However, the replacements have been approached in a like-for-like manner, meaning that they do not take advantage of the inherent capabilities of digital technology to improve business functions. And so, the improvement in I&C system performance has not translated to bottom-line performance improvement for the fleet. Therefore, wide-scale modernization of the legacy I&C systems could prove to be cost-prohibitive unless the technology is implemented in a manner to enable significant business innovation as a means of off-setting the cost of upgrades. A Future Vision of a transformed nuclear plant operating model based on an integrated digital environment has been developed as part of the Advanced Instrumentation, Information, and Control (II&C) research pathway, under the Light Water Reactor (LWR) Sustainability Program. This is a research and development program sponsored by the U.S. Department of Energy (DOE), performed in close collaboration with the nuclear utility industry, to provide the technical foundations for licensing and managing the long-term, safe and economical operation of current nuclear power plants. DOE’s program focus is on longer-term and higher-risk/reward research that contributes to the national policy objectives of energy security and environmental security . The Advanced II&C research pathway is being conducted by the Idaho National Laboratory (INL). The Future Vision is based on a digital architecture that encompasses all aspects of plant operations and support, integrating plant systems, plant work processes, and plant workers in a

  20. Long-Term Instrumentation, Information, and Control Systems (II&C) Modernization Future Vision and Strategy

    Energy Technology Data Exchange (ETDEWEB)

    Kenneth Thomas

    2012-02-01

    Life extension beyond 60 years for the U.S operating nuclear fleet requires that instrumentation and control (I&C) systems be upgraded to address aging and reliability concerns. It is impractical for the legacy systems based on 1970's vintage technology operate over this extended time period. Indeed, utilities have successfully engaged in such replacements when dictated by these operational concerns. However, the replacements have been approached in a like-for-like manner, meaning that they do not take advantage of the inherent capabilities of digital technology to improve business functions. And so, the improvement in I&C system performance has not translated to bottom-line performance improvement for the fleet. Therefore, wide-scale modernization of the legacy I&C systems could prove to be cost-prohibitive unless the technology is implemented in a manner to enable significant business innovation as a means of off-setting the cost of upgrades. A Future Vision of a transformed nuclear plant operating model based on an integrated digital environment has been developed as part of the Advanced Instrumentation, Information, and Control (II&C) research pathway, under the Light Water Reactor (LWR) Sustainability Program. This is a research and development program sponsored by the U.S. Department of Energy (DOE), performed in close collaboration with the nuclear utility industry, to provide the technical foundations for licensing and managing the long-term, safe and economical operation of current nuclear power plants. DOE's program focus is on longer-term and higher-risk/reward research that contributes to the national policy objectives of energy security and environmental security . The Advanced II&C research pathway is being conducted by the Idaho National Laboratory (INL). The Future Vision is based on a digital architecture that encompasses all aspects of plant operations and support, integrating plant systems, plant work processes, and plant workers in a

  1. Room-temperature triggered single photon emission from a III-nitride site-controlled nanowire quantum dot.

    Science.gov (United States)

    Holmes, Mark J; Choi, Kihyun; Kako, Satoshi; Arita, Munetaka; Arakawa, Yasuhiko

    2014-02-12

    We demonstrate triggered single photon emission at room temperature from a site-controlled III-nitride quantum dot embedded in a nanowire. Moreover, we reveal a remarkable temperature insensitivity of the single photon statistics, and a g((2))[0] value at 300 K of just 0.13. The combination of using high-quality, small, site-controlled quantum dots with a wide-bandgap material system is crucial for providing both sufficient exciton confinement and an emission spectrum with minimal contamination in order to enable room temperature operation. Arrays of such single photon emitters will be useful for room-temperature quantum information processing applications such as on-chip quantum communication.

  2. Gold nanoparticle assemblies of controllable size obtained by hydroxylamine reduction at room temperature

    Energy Technology Data Exchange (ETDEWEB)

    Tódor, István Sz.; Szabó, László; Marişca, Oana T.; Chiş, Vasile; Leopold, Nicolae, E-mail: nicolae.leopold@phys.ubbcluj.ro [Babeş-Bolyai University, Faculty of Physics (Romania)

    2014-12-15

    Colloidal nanoparticle assemblies (NPAs) were obtained in a one-step procedure, by reduction of HAuCl{sub 4} by hydroxylamine hydrochloride, at room temperature, without the use of any additional nucleating agent. By changing the order of the reactants, NPAs with mean size of ∼20 and ∼120 nm were obtained. Because of their size and irregular popcorn like shape, the larger size NPAs show absorption in the NIR spectral region. The building blocks of the resulted nanoassemblies are spherical nanoparticles with diameters of 4–8 and 10–30 nm, respectively. Moreover, by stabilizing the colloid with bovine serum albumin at different time moments after synthesis, NPAs of controlled size between 20 and 120 nm, could be obtained. The NPAs were characterized using UV–Vis spectroscopy, TEM and SEM electron microscopies. In addition, the possibility of using the here proposed NPAs as surface-enhanced Raman scattering (SERS) substrate was assessed and found to provide a higher enhancement compared to conventional citrate-reduced nanoparticles.

  3. Gold nanoparticle assemblies of controllable size obtained by hydroxylamine reduction at room temperature

    Science.gov (United States)

    Tódor, István Sz.; Szabó, László; Marişca, Oana T.; Chiş, Vasile; Leopold, Nicolae

    2014-12-01

    Colloidal nanoparticle assemblies (NPAs) were obtained in a one-step procedure, by reduction of HAuCl4 by hydroxylamine hydrochloride, at room temperature, without the use of any additional nucleating agent. By changing the order of the reactants, NPAs with mean size of 20 and 120 nm were obtained. Because of their size and irregular popcorn like shape, the larger size NPAs show absorption in the NIR spectral region. The building blocks of the resulted nanoassemblies are spherical nanoparticles with diameters of 4-8 and 10-30 nm, respectively. Moreover, by stabilizing the colloid with bovine serum albumin at different time moments after synthesis, NPAs of controlled size between 20 and 120 nm, could be obtained. The NPAs were characterized using UV-Vis spectroscopy, TEM and SEM electron microscopies. In addition, the possibility of using the here proposed NPAs as surface-enhanced Raman scattering (SERS) substrate was assessed and found to provide a higher enhancement compared to conventional citrate-reduced nanoparticles.

  4. Virtual Visit to the ATLAS Control Room by the Southdown Primary School in Huntington

    CERN Multimedia

    ATLAS Experiment

    2012-01-01

    This ATLAS Virtual Visit is being conducted with Mrs. Triessl's 4th grade class at the Southdown Primary School in Huntington, NY. The students of Mrs. Triessl's class have been studying together in an innovative Dual-Language (Spanish/English) program since kindergarten. In spite of the extra academic effort this program requires, the curriculum has maintained a strong and increasing focus on science education. The students have begun this year learning about matter and energy and look forward to meeting a real scientist addressing these topics in a laboratory far across the ocean! The school and the district are thrilled to have this opportunity, which they hope will inspire their students toward future participation in their growing K-12 scientific programs (see http://www.hufsd.edu/academics/science/science_index.html). http://atlas-live-virtual-visit.web.cern.ch/atlas-live-virtual-visit/2012/Huntington-2012.html Steven Goldfarb and Kate Shaw in the ATLAS Control Room and students of the 4th grade class a...

  5. Development of Alarm System link Drawing for Operation Support for APR1400 Digital Main Control Room

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ki-Hwan [KHNP CRI, Daejeon (Korea, Republic of)

    2016-10-15

    Digitalized MMI(Man-Machine Interface) including Digital Main Control Room(MCR) and digital I and C system was being applied for SKN 3 and 4 Nuclear Power Plant(NPP) and subsequent APR1400 NPP type. But, operators can not easily find instrument for alarm immediately. Therefore, Alarm system is required to easily find instrument for Alarm. For this implementation, we will plan system design considering design feature without affecting network load and CPU load. We have developed Alarm system link drawing for digital MCR. Operators of the digitalized MCR navigates from their consoles to the drawings related to the plant alarms and their instruments or the operation status. Such method gives cognitive load to the operators having to travel to different locations in finding the related information. Screen Sharing System, which is the fundamental technique for Drawing Interconnection Alarm System is close to completion, and it should be functionally tested and verified by the human factor engineering. For the actual application to the operating plants, the drawings to be interconnected to the alarms and the opinions from the operators/maintenance departments for designating alarm number should be surveyed, Also, another function that allows the access to the alarm related drawings not only from the MCR but also from the other offices.

  6. REVIEW Of COMPUTERIZED PROCEDURE GUIDELINES FOR NUCLEAR POWER PLANT CONTROL ROOMS

    Energy Technology Data Exchange (ETDEWEB)

    David I Gertman; Katya Le Blanc; Ronald L Boring

    2011-09-01

    Computerized procedures (CPs) are recognized as an emerging alternative to paper-based procedures for supporting control room operators in nuclear power plants undergoing life extension and in the concept of operations for advanced reactor designs. CPs potentially reduce operator workload, yield increases in efficiency, and provide for greater resilience. Yet, CPs may also adversely impact human and plant performance if not designed and implemented properly. Therefore, it is important to ensure that existing guidance is sufficient to provide for proper implementation and monitoring of CPs. In this paper, human performance issues were identified based on a review of the behavioral science literature, research on computerized procedures in nuclear and other industries, and a review of industry experience with CPs. The review of human performance issues led to the identification of a number of technical gaps in available guidance sources. To address some of the gaps, we developed 13 supplemental guidelines to support design and safety. This paper presents these guidelines and the case for further research.

  7. Virtual Visit to the ATLAS Control Room by the Vancouver Community Science Celebration

    CERN Document Server

    ATLAS Experiment

    2012-01-01

    October 13th and 14th, 2012. This is the first event of its kind at TELUS World of Science, and we want you to be there. Let's celebrate the science all around us at the Vancouver Community Science Celebration at TELUS World of Science! October 14, 13:30 local (22:30 CET) Sunday's program will feature a live link to the ATLAS control room at CERN's Large Hadron Collider. This will give visitors the amazing opportunity to ask questions to the physicists involved about the LHC experiments, Higgs particles and antimatter. As well as to discover how scientists in Canada and at CERN are all looking back through deep time to answer those big questions on the origins of life, the universe and everything. Doors to the Science Theatre will open at 1:15 pm and space is limited to the first 200 through the door.. http://atlas-live-virtual-visit.web.cern.ch/atlas-live-virtual-visit/2012/Vancouver-2012.html

  8. Virtual Visit to the ATLAS Control Room during Researchers Night by Natural History Museum, London

    CERN Multimedia

    ATLAS Experiment

    2012-01-01

    This event is part of EU Researchers Night, when institutions in more than 200 cities across Europe reveal the exciting science research taking place behind their doors and how science research is exciting, fun and vital to our daily lives. Following the success of Science Uncovered in 2010 and 2011, the Natural History Museum, London throws open its doors once again this September. There will be hundreds of inspiring scientific activities happening throughout the Museum's iconic galleries and behind the scenes. One big part of the night is a series of Nature Live events, where visitors get the chance to meet our scientists, see the specimens they study and join in the discussion. Throughout the night these events will feature live links to other scientific institutions across the world, including to the LHC control room at CERN. This will give visitors the amazing opportunity to ask questions to the physicists involved about the Large Hadron Collider experiments, Higgs particles and antimatter. As well as to...

  9. Virtual Visit to the ATLAS Control Room by The Higgs in Tour, Bologna

    CERN Multimedia

    ATLAS Experiment

    2012-01-01

    "HIGGS IN TOUR: A discovery in the making" - Three science shows touring Emilia Romagna (Italy), organized by INFN, the Istituto Nazionale di Fisica Nucleare in Bologna and by the University of Bologna. Three legs are scheduled in the cities of: - Forlì : 13 Oct. - Reggio Emilia : 10 Nov. - Bologna : 17 Nov. The announcement of the discovery of a new particle compatible with the Higgs boson at CERN last July hit the headlines worldwide. The general public and students in these cities are ready and greedy to know more and meet the scientists behind the discovery. Within the 2 hour programmes, particle physicists from Bologna will take the floor at the venues in Italy and from the LHC experiments' control rooms at CERN through videoconferencing. Videos and animations will make the LHC experiments and the physics discoveries tangible for the audience, who will be able to interact with the scientists in town and at CERN. The event will be moderated by local host Patrizio Roversi (a tv star in Italy) and remote h...

  10. Virtual Visit to the ATLAS Control Room by The Higgs in Tour, Forlì, Italy

    CERN Multimedia

    ATLAS Experiment

    2012-01-01

    "HIGGS IN TOUR: A discovery in the making" - Three science shows touring Emilia Romagna (Italy), organized by INFN, the Istituto Nazionale di Fisica Nucleare in Bologna and by the University of Bologna. Three legs are scheduled in the cities of: - Forlì : 13 Oct. - Reggio Emilia : 10 Nov. - Bologna : 17 Nov. The announcement of the discovery of a new particle compatible with the Higgs boson at CERN last July hit the headlines worldwide. The general public and students in these cities are ready and greedy to know more and meet the scientists behind the discovery. Within the 2 hour programmes, particle physicists from Bologna will take the floor at the venues in Italy and from the LHC experiments' control rooms at CERN through videoconferencing. Videos and animations will make the LHC experiments and the physics discoveries tangible for the audience, who will be able to interact with the scientists in town and at CERN. The event will be moderated by local host Patrizio Roversi (a tv star in Italy) and remote h...

  11. Effects of Shift Work on Cognitive Performance, Sleep Quality, and Sleepiness among Petrochemical Control Room Operators.

    Science.gov (United States)

    Kazemi, Reza; Haidarimoghadam, Rashid; Motamedzadeh, Majid; Golmohamadi, Rostam; Soltanian, Alireza; Zoghipaydar, Mohamad Reza

    2016-02-03

    Shift work is associated with both sleepiness and reduced performance. The aim of this study was to examine cognitive performance, sleepiness, and sleep quality among petrochemical control room shift workers. Sixty shift workers participated in this study. Cognitive performance was evaluated using a number of objective tests, including continuous performance test, n-back test, and simple reaction time test; sleepiness was measured using the subjective Karolinska Sleepiness Scale (KSS); and sleep quality was assessed using the Pittsburgh Sleep Quality Index (PSQI) questionnaire. ANCOVA, t-test, and repeated-measures ANOVA were applied for statistical analyses, and the significance level was set at p sleep quality on both day and night shifts, and there were significant differences between the day and night shifts in terms of subjective sleep quality and quantity (p sleep, induced cognitive performance decline at the end of both day and night shifts, and increased sleepiness in night shift. It, thus, seems necessary to take ergonomic measures such as planning for more appropriate shift work and reducing working hours.

  12. Use of modern birth control methods among rural communities in Imo State, Nigeria.

    Science.gov (United States)

    Nwachukwu, Ike; Obasi, O O

    2008-04-01

    This paper studied the extent of utilization of Modern Birth Control Methods (MBCM) among rural dwellers in Imo State Nigeria. Three hundred and sixty households were randomly selected and data were obtained from them with the use of questionnaires and Focus Group Discussion. The results showed that only 30% of the respondents used MBCM while 57% of them used the traditional birth control methods. The most popular modern method was the condom (24.2%). This was followed by the IUD, used by only 2.5% of the respondents. Some of the identified factors that hindered the use of MBCM included perceived negative health reaction, fear of the unknown effects, cost, spouse's disapproval, religious belief and inadequate information. For a better understanding and utilization of MBCM, it is recommended that adequate educational campaign should be mounted in the rural areas on the advantages of MBCM. This campaign should target the men the more because they make the major decisions on MBCM use.

  13. Demonstrator Flood Control Room : Inventarisatie van de wensen van de verschillende Deltares onderdelen en een hierop gebaseerd ontwerp

    NARCIS (Netherlands)

    Boertjens, G.J.; Attema-van Waas, A.R.; Guikema, M.; Schilder, C.M.C.; Veen, M.J. van der

    2009-01-01

    Op basis van het uitgevoerde onderzoek trekt TNO de volgende conclusies: • De bestaande ruimte die Deltares op het oog heeft voor de realisatie van de trainingsruimte is klein. Een eerste fase van de gewenste Flood Control Room is realiseerbaar in deze ruimte, met inachtneming dat niet alle geïdenti

  14. Conventional heat distribution systems and their control for room cooling; Konventionelle Waermeabgabesysteme und deren Regulierung fuer die Raumkuehlung - Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Schnyder, J. [Schnyder-Energie, Energie-Dienstleistungen, Bronschhofen (Switzerland); Feger, D.; Graf, J.; Rusterholtz, R. [Interstaatliche Hochschule fuer Technik Buchs NTB, Buchs (Switzerland); Schoeringhumer, D.; Cenci, D. [Arbonia AG, Arbon (Switzerland); Heule, D. [hps energieconsulting ag, Ingenieurbuero fuer nachhaltige Energie- und Gebaeudetechnik, Kuesnacht (Switzerland)

    2009-12-15

    This final report for the Swiss Federal Office of Energy (SFOE) examines how conventional heat distribution systems such as radiators and floor heating systems can be used for room cooling and the appropriate control requirements. Thermostatic valves used 'in reverse', their functional testing and the results obtained are discussed. Possibilities for their optimisation are examined. The apparatus used for the measurements made on both radiator and floor-heating systems is reported on and the results obtained are presented and discussed. Further, simulations used are looked at and examples of the results obtained for rooms with varying glazed surfaces are presented and discussed.

  15. Athletic Lockers for Schools and Colleges; Their Design--Selection--and Purchase with Functional Tips and Suggestions for the Modern Athletic Locker Room.

    Science.gov (United States)

    Dickey, Donald D.

    Information is provided relative to the design, selection, and purchase of locker equipment for athletic and physical education use. Some suggestions offered are for both specific applications, and some are general to any locker dressing room. Among the topics discussed are construction and joining of lockers, ventilation and drying,…

  16. Control of Single-room Ventilation with Regenerative Heat Recovery for Indoor Climate and Energy Performance

    OpenAIRE

    Smith, Kevin Michael; Svendsen, Svend

    2016-01-01

    The Danish government will seek energy-efficiency improvements to meet their targeted aims. Single-room ventilation with heat recovery allows simple installation through the façade and may be broadly deployed in apartments. Danish building regulations require greater than 80% heat recovery in new constructions and will soon require 85%. The development of single-room ventilation units may aim for these requirements as a result. The exhaust temperatures in highly efficient heat exchangers may ...

  17. The historic Proton Synchrotron (PS) control room is about to start a new life. Opened by Niels Bohr in 1960, the room will be reused by CMS to built its control centre. When finished, it will resemble the CERN Control Centre for LHC operations, located in Prevessin.

    CERN Multimedia

    Husi C.

    2007-01-01

    The historic Proton Synchrotron (PS) control room is about to start a new life. Opened by Niels Bohr in 1960, the room will be reused by CMS to built its control centre. When finished, it will resemble the CERN Control Centre for LHC operations, located in Prevessin.

  18. Full scope simulator of a nuclear power plant control room using 3D stereo virtual reality techniques for operators training

    Energy Technology Data Exchange (ETDEWEB)

    Aghina, Mauricio A.C.; Mol, Antonio Carlos A.; Almeida, Adino Americo A.; Pereira, Claudio M.N.A. [Instituto de Engenharia Nuclear (IEN-CNEN/RJ), Rio de Janeiro, RJ (Brazil)]. E-mails: mag@ien.gov.br; mol@ien.gov.br; adino@ien.gov.br; cmnap@ien.gov.br; Varela, Thiago F.B. [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia (COPPE). Programa de Engenharia Eletrica]. E-mail: phillips.rj@terra.com.br; Cunha, Gerson G. [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia (COPPE). Lab. de Metodos Computacionais em Engenharia (LAMCE)]. E-mail: gerson@lance.ufrj.br

    2007-07-01

    Practical training of nuclear power plants operators are partially performed by means of simulators. Usually these simulators are physical copies of the original control roam, needing a large space on a facility being also very expensive. In this way, the proposal of this paper is to implement the use of Virtual Reality techniques to design a full scope control room simulator, in a manner to reduce costs and physical space usage. (author)

  19. Two-Person Control: A Brief History and Modern Industry Practices

    Energy Technology Data Exchange (ETDEWEB)

    Pedersen, Robert Douglas [Sandia National Lab. (SNL-CA), Livermore, CA (United States)

    2017-07-01

    Physical asset protection is the principal objective of many security and safeguard measures. One well-known means of asset protection is two-person control. This paper reviews literature regarding two-person control to gain insight into its origin, first demonstrated uses, and its presence in several modern industries. This literature review of two-person control is intended to benefit people and organizations with a desire to understand its origins and how the practice has evolved over time, as well as give some insight into the flexibility of this safeguarding technique. The literature review is focused in four main sections: (1) defining two-person control, (2) early history, (3) two-person control in modern industry, and (4) a theory on how two- person control entered modern industry. ACKNOWLEDGEMENTS The author would like to thank Jarret Lafleur and Scott Paap of Sandia National Laboratories, California's Systems Analysis & Engineering organization for the opportunity to work on this project. Jarret Lafleur provided very constructive and helpful feedback through all stages of the work. Amanda Thompson of the Sandia California Technical Library maintained a great spirit and always had a quick document turnaround that very much helped out this project's completion. Additionally, yet perhaps most importantly, the author would like to thank his wife and daughter, along with the rest of his family, for continued support over the years. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology and Engineering Solutions of Sandia, LLC., a wholly owned subsidiary of Honeywell International, Inc., for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-NA0003525.

  20. Modernization of control system using the digital control system; Modernizacion de sistemas de control usando la simulacion como herramiento de ingenieria

    Energy Technology Data Exchange (ETDEWEB)

    Carrasco, J. A.; Fernandez, L.; Jimenez, A.

    2002-07-01

    Nowadays, all plant automation tendencies are based on the use of Digital Control System. In big industrial plants the control systems employed are Distributed Control Systems (DCS). The addition of these systems in nuclear power plants,implies an important adaptation process, because most of them were installed using analog control systems. This paper presents the objectives and the first results obtained, in a modernization project, focused in obtaining an engineering platform for making test and analysis of changes prior to their implementation in a nuclear plant. Modernization, Upgrade, DCS, Automation, Simulation, Training. (Author)

  1. Human factors design, verification, and validation for two types of control room upgrades at a nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Boring, Laurids Ronald [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-10-01

    This paper describes the NUREG-0711 based human factors engineering (HFE) phases and associated elements required to support design, verification and validation (V&V), and implementation of a new plant process computer (PPC) and turbine control system (TCS) at a representative nuclear power plant. This paper reviews ways to take a human-system interface (HSI) specification and use it when migrating legacy PPC displays or designing displays with new functionality. These displays undergo iterative usability testing during the design phase and then undergo an integrated system validation (ISV) in a full scope control room training simulator. Following the successful demonstration of operator performance with the systems during the ISV, the new system is implemented at the plant, first in the training simulator and then in the main control room.

  2. PHYSICAL FIDELITY CONSIDERATIONS FOR NRC ADVANCED REACTOR CONTROL ROOM TRAINING SIMULATORS USED FOR INSPECTOR/EXAMINER TRAINING

    Energy Technology Data Exchange (ETDEWEB)

    Branch, Kristi M.; Mitchell, Mark R.; Miller, Mark; Cochrum, Steven

    2010-11-07

    This paper describes research into the physical fidelity requirements of control room simulators to train U.S. Nuclear Regulatory Commission (NRC) staff for their duties as inspectors and license examiners for next-generation nuclear power plants. The control rooms of these power plants are expected to utilize digital instrumentation and controls to a much greater extent than do current plants. The NRC is assessing training facility needs, particularly for control room simulators, which play a central role in NRC training. Simulator fidelity affects both training effectiveness and cost. Research has shown high simulation fidelity sometimes positively affects transfer to the operational environment but sometimes makes no significant difference or actually impedes learning. The conditions in which these different effects occur are often unclear, especially for regulators (as opposed to operators) about whom research is particularly sparse. This project developed an inventory of the tasks and knowledges, skills, and abilities that NRC regulators need to fulfill job duties and used expert panels to characterize the inventory items by type and level of cognitive/behavioral capability needed, difficulty to perform, importance to safety, frequency of performance, and the importance of simulator training for learning these capabilities. A survey of current NRC staff provides information about the physical fidelity of the simulator on which the student trained to the control room to which the student was assigned and the effect lack of fidelity had on learning and job performance. The study concludes that a high level of physical fidelity is not required for effective training of NRC staff.

  3. An Methodology for Quality Control and Draught Assessment of Room Ventilation Supply Using Laser Light Sheets

    DEFF Research Database (Denmark)

    Hviid, Christian Anker; Petersen, Steffen

    2016-01-01

    A common technique to investigate draught problems in a room is to make spot measurements of air velocity. This might identify where the draught problem is located but it does not necessarily identify the distribution and source of the problem. Usually visual inspections of the location of ventil...

  4. Design of a modern automatic control system for the activated sludge process in wastewater treatment

    Institute of Scientific and Technical Information of China (English)

    Alexandros D. Kotzapetros; Panayotis A. Paraskevas; Athanasios S. Stasinakis

    2015-01-01

    The Activated Sludge Process (ASP) exhibits highly nonlinear properties. The design of an automatic control system that is robust against disturbance of inlet wastewater flow rate and has short process settling times is a chal enging matter. The proposed control method is an I-P modified controller automatic control system with state variable feedback and control canonical form simulation diagram for the process. A more stable response is achieved with this type of modern control. Settling times of 0.48 days are achieved for the concentration of microorganisms, (reference value step increase of 50 mg·L−1) and 0.01 days for the concentration of oxygen (reference value step increase of 0.1 mg·L−1). Fluctuations of concentrations of oxygen and microorganisms after an inlet disturbance of 5 × 103m3·d−1 are smal . Changes in the reference values of oxygen and microorganisms (increases by 10%, 20%and 30%) show satisfactory response of the system in al cases. Changes in the value of inlet wastewater flow rate disturbance (increases by 10%, 25%, 50%and 100%) are stabilized by the control system in short time. Maximum percent overshoot is also taken in consideration in all cases and the largest value is 25%which is acceptable. The proposed method with I-P controller is better for disturbance rejection and process settling times compared to the same method using PI control er. This method can substitute optimal control systems in ASP.

  5. Modern bel canto singing room acoustics system construction inquiry%现代美声演唱中室内声学系统建设探究

    Institute of Scientific and Technical Information of China (English)

    史广义

    2014-01-01

    This paper according to the specific needs of bel canto singing,based on the analysis of indoor reverberation time measurement on to VRAS as an example to explore the feasibility of building and room acoustics systems is important.%本文根据美声演唱的具体需要,在分析了室内混响时间测量方式的基础上,以VRAS(可变室内声学系统)为例探究了室内声学系统建设的可行性及重要意义。

  6. Development of human performance evaluation battery for integrated system validation of the HSI for an advanced control room

    Energy Technology Data Exchange (ETDEWEB)

    Hsu, S. H. [National Chiao Tung Univ., 1001 Ta Hsueh Road, Hsinchu, 30010, Taiwan (China); Wu, T. M.; Lee, J. Y. [Dept. of Nuclear Engineering, Taiwan Power Company, 242 Roosevelt Road, Taipei, 100 Taiwan (China)

    2006-07-01

    The human-system interface (HSI) plays a vital role in the operation of a nuclear power plant. To ensure a human factors engineered advanced control room HSI design in support of reliable and safe operation of the plant, Taiwan Power Company has incorporated elements of the HFE Program Review Model (HFE PRM), prescribed in NUREG-0711 [1], into the HFE program for its Lungmen Nuclear Power Project. At present, the control room HSI design is undergoing verification and validation. Although NUREG/CR-6393[2] has introduced review criteria and methodology for integrated system validation, these criteria and methodology need to be elaborated for proper implementation. The purpose of this paper is to describe the development of suitable performance evaluation tools to be used to collect objective task performance measures, cognitive measures, as well as physical measures for HFE validation for the Lungmen project. (authors)

  7. A Novel Grid-Wide Transient Stability Assessment and Visualization Method for Increasing Situation Awareness of Control Room Operators

    DEFF Research Database (Denmark)

    Pertl, Michael; Rezkalla, Michel M.N.; Marinelli, Mattia

    2016-01-01

    The aim of the paper is to introduce a grid-wide assessment method to determine the transient stability margin and visualize it effectively to increase the situation awareness of control room operators. Critical area(s) with insufficient transient stability margin have to be identified in order...... to be able to take appropriate preventive actions. The introduced method evaluates the transient stability margin with a time-domain approach by using the voltage angle of several buses across the power system. Information about the severity of a contingency and the location of the most critical buses...... is derived. Moreover, it is shown that the method facilitates the visual examination of transient stability. It provides control room operators with essential information about the state of the system and enables them to take appropriate preventive actions if insufficient transient stability margins...

  8. A methodology for Living Probabilistic Safety Assessment (LPSA) based on Advanced Control Room Operator Support System (ACROSS)

    Energy Technology Data Exchange (ETDEWEB)

    Zubair, Muhammad, E-mail: zubairheu@gmail.com [College of Nuclear Science and Technology, Harbin Engineering University, 145 Nantong Street, Nangang District, Harbin, Heilongjiang 150001 (China); Zhang Zhijian, E-mail: zhangzhijian@hrbeu.edu.cn [College of Nuclear Science and Technology, Harbin Engineering University, 145 Nantong Street, Nangang District, Harbin, Heilongjiang 150001 (China); Khan, Salah Ud-din, E-mail: khanheu@gmail.com [College of Nuclear Science and Technology, Harbin Engineering University, 145 Nantong Street, Nangang District, Harbin, Heilongjiang 150001 (China)

    2011-06-15

    Highlights: > In this study we have introduced a methodology for Living Probabilistic Safety Assessment (LPSA). > Now the paper is focus on LPSA methodology for this purpose we introduced Advanced Control Room Operator Support System (ACROSS). > The ACROSS concept is new technique in LPSA and it's a part of our research project. > Detail is present in Section of paper. > We have also added to provide more detail about methodology. > We have remove Risk monitor portion from our paper and give more attention to LPSA methodology. - Abstract: In Probabilistic Safety Assessment (PSA) all attention is paid to analyze a system which is a time consuming effort so there is a need to develop a system network to support the analyst and to reduce manpower. To handle the physical, operational and organizational changes and to utilize the PSA information effectively the development of living Probabilistic Safety Assessment (LPSA) is essential. This paper presents a detailed methodology for LPSA. One part of this methodology is Advanced Control Room Operator Support System (ACROSS) which is helpful for updating the LPSA model. This methodology also provides help to make the control rooms in Nuclear Power Plants (NPPs) more advanced and user friendly. The study also makes recommendations for further use and development of this technique in the present and future NPPs.

  9. Economic analysis of linking operating room scheduling and hospital material management information systems for just-in-time inventory control.

    Science.gov (United States)

    Epstein, R H; Dexter, F

    2000-08-01

    Operating room (OR) scheduling information systems can decrease perioperative labor costs. Material management information systems can decrease perioperative inventory costs. We used computer simulation to investigate whether using the OR schedule to trigger purchasing of perioperative supplies is likely to further decrease perioperative inventory costs, as compared with using sophisticated, stand-alone material management inventory control. Although we designed the simulations to favor financially linking the information systems, we found that this strategy would be expected to decrease inventory costs substantively only for items of high price ($1000 each) and volume (>1000 used each year). Because expensive items typically have different models and sizes, each of which is used by a hospital less often than this, for almost all items there will be no benefit to making daily adjustments to the order volume based on booked cases. We conclude that, in a hospital with a sophisticated material management information system, OR managers will probably achieve greater cost reductions from focusing on negotiating less expensive purchase prices for items than on trying to link the OR information system with the hospital's material management information system to achieve just-in-time inventory control. In a hospital with a sophisticated material management information system, operating room managers will probably achieve greater cost reductions from focusing on negotiating less expensive purchase prices for items than on trying to link the operating room information system with the hospital's material management information system to achieve just-in-time inventory control.

  10. MATLAB Application of Modern Control Theory%现代控制理论的MATLAB实现

    Institute of Scientific and Technical Information of China (English)

    祁汭晗

    2012-01-01

    现代控制理论是对系统的状态进行分析和综合的理论,是自动控制理论的一个主要组成部分.现代控制理论的最基本的分析方法是时域法,是建立在状态空间的基础上,不用传递函数,而是利用状态矢量方程的特点对复杂系统进行系统建模,并进一步通过状态方程求解分析,研究系统的能控性、能观性及其稳定性,分析系统的实现问题.研究MATLAB在状态空间分析法、状态方程求解的方法,简化计算,由此提出借助于MATLAB软件来实现对系统的分析的设想,并进行论证,来实现对现代控制理论系统的分析,如对系统稳定性以及系统能控性、能观性的分析.%Modern control theory, analysis and synthesis of theory s the state of the system is a major component of the automatic control theory. The most basic analytical methods of modern control theory is a time domain method, is built on the basis of the state space, without the transfer function f but the characteristics of the state vector equation system modeling of complex systems, and further solve the equation of state analysis to study the system controllability, observability and its stability analysis system problems- In this paper, MATLAB analysis in the state space, solve the equation of state f simplify the calculation t which put forward the idea of the help of MATLAB software analysis system, and to demonstrate to the modern control theory p system analysis f such as system stability and controllability, observability analysis.

  11. Deployment of a Full-Scope Commercial Nuclear Power Plant Control Room Simulator at the Idaho National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Ronald Boring; Julius Persensky; Kenneth Thomas

    2011-09-01

    The INL operates the HSSL to conduct research in the design and evaluation of advanced reactor control rooms, integration of intelligent support systems to assist operators, development and assessment of advanced human performance models, and visualizations to assess advanced operational concepts across various infrastructures. This advanced facility consists of a reconfigurable simulator and a virtual reality capability (known as the Computer-Aided Virtual Environment (CAVE)) (Figure 2). It supports human factors research, including human-in-the-loop performance, HSI, and analog and digital hybrid control displays. It can be applied to the development and evaluation of control systems and displays for complex systems such as existing and advanced NPP control rooms, command and control systems, and advance emergency operations centers. The HSSL incorporates a reconfigurable control room simulator, which is currently housed in the Center for Advanced Energy Studies (CAES), a joint venture of the DOE and the Idaho University System. The simulator is a platform- and plant-neutral environment intended for full-scope and part-task testing of operator performance in various control room configurations. The simulator is not limited to a particular plant or even simulator architecture. It can support engineering simulator platforms from multiple vendors using digital interfaces. Due to its ability to be reconfigured, it is possible to switch the HSI - not just to digital panels but also to different control modalities such as those using greater plant automation or intelligent alarm filtering. The simulator currently includes three operator workstations, each capable of driving up to eight 30-inch monitors. The size and number of monitors varies depending on the particular front-end simulator deployed for a simulator study. These operator workstations would typically be used for the shift supervisor or senior reactor operator, reactor operator, and assistant reactor

  12. Improvement of Quality of a Modern Commercial Silk Mill through effective Process and Machine Control Parameters

    Directory of Open Access Journals (Sweden)

    Dr. Swapan Kumar Ghosh

    2016-08-01

    Full Text Available This paper deals with international and national scenario of commercial production and market share of silk fabrics with particular reference to process along with machine control parameters followed by adoption of good practices in the preparatory stages during production of the silk fabric in a commercial Silk Mill. An observatory report has been presented here for starting from yarn to the fabric stage, which indicates the major technical reasons for deterioration in the quality of the silk products affecting the cost factor and environment to some extent. This paper delineates an effective monitoring and controlling process variables along with machine parameters at every step of production of silk fabric from its filament yarn stage, particularly during the modern high speed silk twisting process, enhancing the quality of the finished product on one hand and minimizing wastage along with the cost of production and adverse environmental impact on the other

  13. Analysis of modern optimal control theory applied to plasma position and current control in TFTR

    Energy Technology Data Exchange (ETDEWEB)

    Firestone, M.A.

    1981-09-01

    The strong compression TFTR discharge has been segmented into regions where linear dynamics can approximate the plasma's interaction with the OH and EF power supply systems. The dynamic equations for these regions are utilized within the linear optimal control theory framework to provide active feedback gains to control the plasma position and current. Methods are developed to analyze and quantitatively evaluate the quality of control in a nonlinear, more realistic simulation. Tests are made of optimal control theory's assumptions and requirements, and the feasibility of this method for TFTR is assessed.

  14. Traditional endodontic surgery versus modern technique: a 5-year controlled clinical trial.

    Science.gov (United States)

    Tortorici, Silvia; Difalco, Paolo; Caradonna, Luigi; Tetè, Stefano

    2014-05-01

    In this study, we compared outcomes of traditional apicoectomy versus modern apicoectomy, by means of a controlled clinical trial with a 5-year follow-up. The study investigated 938 teeth in 843 patients. On the basis of the procedure performed, the teeth were grouped in 3 groups. Differences between the groups were the method of osteotomy (type of instruments used), type of preparation of retrograde cavity (different apicoectomy angles and instruments used for root-end preparation), and root-end filling material used (gray mineral trioxide aggregate or silver amalgam). Outcome (tooth healing) was estimated after 1 and 5 years, postoperatively. Clinical success rates after 1 year were 67% (306 teeth), 90% (186 teeth), and 94% (256 teeth) according to traditional apicoectomy (group 1), modern microsurgical apicoectomy using burns for osteotomy (group 2) or using piezo-osteotomy (group 3), respectively. After 1 year, group comparison results were statistically significant (P < 0.0001). Linear trend test was also statistically significant (P < 0.0001), pointing out larger healing from group 1 to group 3. After 5 years, teeth were classified into 2 groups on the basis of root-end filling material used. Clinical success was 90.8% (197 teeth) in the silver amalgam group versus 96% (309 teeth) in the mineral trioxide aggregate group (P < 0.00214). Multiple logistic regression analysis found that surgical technique was independently associated to tooth healing. In conclusion, modern apicoectomy resulted in a probability of success more than 5 times higher (odds ratio, 5.20 [95% confidence interval, 3.94-6.92]; P < 0.001) compared with the traditional technique.

  15. Climatic and physiological controls on the stable isotope composition of modern and ancient Cupressaceae

    Science.gov (United States)

    Zinniker, D.; Tipple, B.; Pagani, M.

    2007-12-01

    Unique and abundant secondary metabolites found in waxes and resins of the Callitroid, Cupressoid, and Taxodioid clades of the Cupressaceae family can be identified and quantified in complex mixtures of sedimentary organic compounds. This unusual feature makes it possible to study relatively simple (taxon-specific) isotope systems back in time across the broad array of environments in which these conifers are found. Work on these systems can potentially provide both robust paleoenvironmental proxies (i.e. for source water δD and growing season relative humidity) and quantitative probes into the ecophysiology of these plants in modern and ancient environments. Our research focuses on three genera representing environmental end-members of Cupressaceae - Juniperus, Thuja, and Chamaecyparis - (1) across geographic and environmental gradients in the field, and (2) in specific Holocene and late Pleistocene environmental records. The latter research focuses on peat cores from New England and Oregon and fossil packrat middens from the southwestern United States. Modern transects highlight the sensitivity of Cupressaceae to climatic variables. These include both variables during growth (relative humidity, soil moisture, etc.) and variables affecting seasonal and diurnal growth rates (temperature, winter precipitation, insolation, microhabitat, etc.). Work on ancient records has demonstrated the sensitivity of these unique taxon-specific archives to both subtle and dramatic climate shifts during the Pleistocene and Holocene. This work will result in an improved understanding of climatic and physiological controls on the stable isotopic composition of modern and ancient Cupressaceae - and by extension, other arborescent gymnosperms and C3 plants - providing a framework for understanding more complexly sourced organic inputs to sediments, coals, and petroleum prior to the advent of C4 plants. This research also has direct implications for stratigraphic stable isotope studies

  16. Hypoxia Room

    Data.gov (United States)

    Federal Laboratory Consortium — The Hypoxia Room is a 8x8x8 ft. clear vinyl plastic and aluminum frame construction enclosure located within USAREIM laboratory 028. The Hypoxia Room (manufactured...

  17. Hypoxia Room

    Data.gov (United States)

    Federal Laboratory Consortium — The Hypoxia Room is a 8x8x8 ft. clear vinyl plastic and aluminum frame construction enclosure located within USAREIM laboratory 028. The Hypoxia Room (manufactured...

  18. Performance Enhancement of PID Controllers by Modern Optimization Techniques for Speed Control of PMBL DC Motor

    Directory of Open Access Journals (Sweden)

    M. Antony Freeda Rani

    2015-08-01

    Full Text Available Permanent Magnet Brushless DC motor (PMBL DC is used in a large number of industrial and automotive applications because of their high efficiency, compactness and excellent reliability. However to design an efficient PMBL DC motor, it is necessary to provide an effective controller that has to reduce the overshoot, settling and rise time. In this study, an improved PID controller has been designed by optimizing the parameters of PID controller based on two advanced optimization techniques ANFIS and Cuckoo Search optimization for speed control of a PMBL DC motor. The proposed approach has superior features, including easy implementation, stable convergence characteristic and good computational efficiency. The PMBL DC motor is modeled in SIMULINK implementing the algorithms in MATLAB and the performance evaluation has been studied.

  19. Modern anaesthesia vapourisers

    Directory of Open Access Journals (Sweden)

    Sucharita Chakravarti

    2013-01-01

    Full Text Available Inhalational anaesthetic agents are usually liquids at room temperature and barometric pressure and need to be converted to vapour before being used and this conversion is effected using a vapouriser. Vapourisers have evolved from very basic devices to more complicated ones. Anaesthetists should understand the basic principles of anaesthetic vapouriser, including the principles that affect vapouriser output and how they influence vapouriser design. Most of the modern vapourisers in use are designed to be used between the flow meter and the common gas outlet on the anaesthesia machine. Modern vapourisers are flow and temperature compensated, concentration calibrated, direct reading, dial controlled and are unaffected by positive-pressure ventilation. Safety features include an anti-spill and a select-a-tec mechanism and a specific vapouriser filling device. Desflurane has unique physical properties requiring the use of a specific desflurane vapouriser. The most recently designed vapourisers are controlled by a central processing unit in the anaesthetic machine. The concentration of vapour is continuously monitored and adjusted by altering fresh gas flow through the vapouriser. This article looks at the basic design and functioning of the modern vapourisers.

  20. Modern anaesthesia vapourisers.

    Science.gov (United States)

    Chakravarti, Sucharita; Basu, Srabani

    2013-09-01

    Inhalational anaesthetic agents are usually liquids at room temperature and barometric pressure and need to be converted to vapour before being used and this conversion is effected using a vapouriser. Vapourisers have evolved from very basic devices to more complicated ones. Anaesthetists should understand the basic principles of anaesthetic vapouriser, including the principles that affect vapouriser output and how they influence vapouriser design. Most of the modern vapourisers in use are designed to be used between the flow meter and the common gas outlet on the anaesthesia machine. Modern vapourisers are flow and temperature compensated, concentration calibrated, direct reading, dial controlled and are unaffected by positive-pressure ventilation. Safety features include an anti-spill and a select-a-tec mechanism and a specific vapouriser filling device. Desflurane has unique physical properties requiring the use of a specific desflurane vapouriser. The most recently designed vapourisers are controlled by a central processing unit in the anaesthetic machine. The concentration of vapour is continuously monitored and adjusted by altering fresh gas flow through the vapouriser. This article looks at the basic design and functioning of the modern vapourisers.

  1. Virtual Visit to the ATLAS Control Room by The Federal University of Santa Catarina

    CERN Multimedia

    2013-01-01

    The Associated School of the Federal University of Santa Catarina is a public federal institution located in Florianópolis receiving students from 6 to 18 years old. Physics is taught in the last three school years by 3 teachers, 2 of them were in the CERN teachers Portuguese Language School program in 2009 and 2013. In the year 2013, the program for teaching Modern Physics was implemented consisting in a series of seminars to the students by the school teachers or researchers at the University. In this context, the virtual visit to ATLAS is an excellent opportunity for the students to know more about the universe of the Particle Physics research.

  2. Electric field control of the γ-Al{sub 2}O{sub 3}/SrTiO{sub 3} interface conductivity at room temperature

    Energy Technology Data Exchange (ETDEWEB)

    Christensen, D. V., E-mail: dechr@dtu.dk; Trier, F.; Soosten, M. von; Chen, Y. Z.; Pryds, N. [Department of Energy Conversion and Storage, Technical University of Denmark, Risø Campus, DK-4000 Roskilde (Denmark); Prawiroatmodjo, G. E. D. K.; Jespersen, T. S. [Niels Bohr Institute, Center for Quantum Devices, University of Copenhagen, DK-2100 Copenhagen Ø (Denmark)

    2016-07-11

    Controlling interfaces using electric fields is at the heart of modern electronics. The discovery of the conducting interface between the two insulating oxides LaAlO{sub 3} (LAO) and SrTiO{sub 3} (STO) has led to a number of interesting electric field-dependent phenomena. Recently, it was shown that replacing LAO with a spinel γ-Al{sub 2}O{sub 3} (GAO) allows a good pseudo-epitaxial film growth and high electron mobility at low temperatures. Here, we show that the GAO/STO interface resistance, similar to LAO/STO, can be tuned by orders of magnitude at room temperature using the electric field of a backgate. The resistance change is non-volatile, bipolar, and can be tuned continuously rather than being a simple on/off switch. Exposure to light significantly changes the capabilities to tune the interface resistance. High- and low-resistive states are obtained by annihilation and creation, respectively, of free n-type carriers, and we speculate that electromigration of oxygen vacancies is the origin of the tunability.

  3. Flight control design using a blend of modern nonlinear adaptive and robust techniques

    Science.gov (United States)

    Yang, Xiaolong

    In this dissertation, the modern control techniques of feedback linearization, mu synthesis, and neural network based adaptation are used to design novel control laws for two specific applications: F/A-18 flight control and reusable launch vehicle (an X-33 derivative) entry guidance. For both applications, the performance of the controllers is assessed. As a part of a NASA Dryden program to develop and flight test experimental controllers for an F/A-18 aircraft, a novel method of combining mu synthesis and feedback linearization is developed to design longitudinal and lateral-directional controllers. First of all, the open-loop and closed-loop dynamics of F/A-18 are investigated. The production F/A-18 controller as well as the control distribution mechanism are studied. The open-loop and closed-loop handling qualities of the F/A-18 are evaluated using low order transfer functions. Based on this information, a blend of robust mu synthesis and feedback linearization is used to design controllers for a low dynamic pressure envelope of flight conditions. For both the longitudinal and the lateral-directional axes, a robust linear controller is designed for a trim point in the center of the envelope. Then by including terms to cancel kinematic nonlinearities and variations in the aerodynamic forces and moments over the flight envelope, a complete nonlinear controller is developed. In addition, to compensate for the model uncertainty, linearization error and variations between operating points, neural network based adaptation is added to the designed longitudinal controller. The nonlinear simulations, robustness and handling qualities analysis indicate that the performance is similar to or better than that for the production F/A-18 controllers. When the dynamic pressure is very low, the performance of both the experimental and the production flight controllers is degraded, but Level I handling qualities are still achieved. A new generation of Reusable Launch Vehicles

  4. 2D or 3D? New user interfaces for control rooms in process industries. A feasibility study; 2D eller 3D? Nya graenssnitt foer processindustrins kontrollrum

    Energy Technology Data Exchange (ETDEWEB)

    Karlsson, MariAnne

    2008-01-15

    Three dimensional user interfaces and techniques for visualisation have been discussed as possible ways to improve the work situation for control room operators in process industries. The aims of the project, which is a pilot project, has been: (i) to compile existing knowledge on the pro's and con's of 2D versus 3D user interfaces in order to assess and conclude if, and how, 3-dimensional visualisations could be applied when designing new user interfaces for modern process control rooms and (ii) to investigate operators' attitudes towards and acceptance of 3-dimensional user interfaces for visualisation of information. The project has included the following activities: a literature review has been completed in order to collect information on different projects and tests in which 3-dimensional user interfaces have been evaluated for different tasks; an identification of feasible use cases has been made, partly on basis of a workshop in which participated researchers from the field and partly on basis of study visits to different process plants on the west coast of Sweden; an interview study has been carried with control room operators at four different power plants in order to find out the operators' assessments of and attitudes towards 3-dimensional information visualisation; and interviews with representatives of system developers have been completed in order to elicit information on ongoing development work and experiences of developing and implementing 3-dimensional user interfaces in control rooms. On basis of the literature review as well as the interview studies cannot be concluded that 3-dimensional user interfaces and 3-dimensional visualisation of information hold any general advantages compared to 2-dimensional solutions. Pro's and con's are, instead, highly contextual and dependant upon (i) the characteristics of user (in terms e.g. of computer skills); (ii) the (work) task; and (iii) the specific design of the user

  5. Adaptive Backstepping Sliding-Mode Control of the Electronic Throttle System in Modern Automobiles

    Directory of Open Access Journals (Sweden)

    Rui Bai

    2014-01-01

    Full Text Available In modern automobiles, electronic throttle is a DC-motor-driven valve that regulates air inflow into the vehicle’s combustion system. The electronic throttle is increasingly being used in order to improve the vehicle drivability, fuel economy, and emissions. Electronic throttle system has the nonlinear dynamical characteristics with the unknown disturbance and parameters. At first, the dynamical nonlinear model of the electronic throttle is built in this paper. Based on the model and using the backstepping design technique, a new adaptive backstepping sliding-mode controller of the electronic throttle is developed. During the backstepping design process, parameter adaptive law is designed to estimate the unknown parameter, and sliding-mode control term is applied to compensate the unknown disturbance. The proposed controller can make the actual angle of the electronic throttle track its set point with the satisfactory performance. Finally, a computer simulation is performed, and simulation results verify that the proposed control method can achieve favorable tracking performance.

  6. System ID Modern Control Algorithms for Active Aerodynamic Load Control and Impact on Gearbox Loading

    NARCIS (Netherlands)

    Berg, D.; Wilson, D.; Resor, B.; Berg, J.; Barlas, J.; Crowther, A.; Halse, C.

    2010-01-01

    Prior work on active aerodynamic load control (AALC) of wind turbine blades has demonstrated that appropriate use of this technology has the potential to yield significant reductions in blade loads, leading to a decrease in wind cost of energy. While the general concept of AALC is usually discussed

  7. System ID Modern Control Algorithms for Active Aerodynamic Load Control and Impact on Gearbox Loading

    NARCIS (Netherlands)

    Berg, D.; Wilson, D.; Resor, B.; Berg, J.; Barlas, J.; Crowther, A.; Halse, C.

    2010-01-01

    Prior work on active aerodynamic load control (AALC) of wind turbine blades has demonstrated that appropriate use of this technology has the potential to yield significant reductions in blade loads, leading to a decrease in wind cost of energy. While the general concept of AALC is usually discussed

  8. Coexistence of electric field controlled ferromagnetism and resistive switching for TiO{sub 2} film at room temperature

    Energy Technology Data Exchange (ETDEWEB)

    Ren, Shaoqing; Qin, Hongwei; Bu, Jianpei; Zhu, Gengchang; Xie, Jihao; Hu, Jifan, E-mail: hujf@sdu.edu.cn, E-mail: hu-jf@vip.163.com [School of Physics, State Key Laboratory for Crystal Materials, Shandong University, Jinan 250100 (China)

    2015-08-10

    The Ag/TiO{sub 2}/Nb:SrTiO{sub 3}/Ag device exhibits the coexistence of electric field controlled ferromagnetism and resistive switching at room temperature. The bipolar resistive switching in Ag/TiO{sub 2}/Nb:SrTiO{sub 3}/Ag device may be dominated by the modulation of Schottky-like barrier with the electron injection-trapped/detrapped process at the interface of TiO{sub 2}/Nb:SrTiO{sub 3}. We suggest that the electric field-induced magnetization modulation originates mainly from the creation/annihilation of lots of oxygen vacancies in TiO{sub 2}.

  9. Draft audit report, human factors engineering control room design review: Saint Lucie Nuclear Power Plant, Unit No. 2

    Energy Technology Data Exchange (ETDEWEB)

    Peterson, L.R.; Lappa, D.A.; Moore, J.W.

    1981-09-03

    A human factors engineering preliminary design review of the Saint Lucie Unit 2 control room was performed at the site on August 3 through August 7, 1981. This design review was carried out by a team from the Human Factors Engineering Branch, Division of Human Factors Safety. This report was prepared on the basis of the HFEB's review of the applicant's Preliminary Design Assessment and the human factors engineering design review/audit performed at the site. The review team included human factors consultants from BioTechnology, Inc., Falls Church, Virginia, and from Lawrence Livermore National Laboratory (University of California), Livermore, California.

  10. Analysis of hospital infection control awareness of ultrasound room office personnel in Busan

    Energy Technology Data Exchange (ETDEWEB)

    Kim, JJung Hoon; Kang, Se Sik; Kim, Chang Soo [Dept. of Radiological Science, College of Health Sciences, Catholic University of Pusan, Pusan (Korea, Republic of)

    2015-06-15

    146 people working in the ultrasound room in Busan were surveyed, and their perception of hospital infection was analyzed. According to the results of the survey, academic background showed the highest number in terms of awareness and performance of personal hygiene management and hand washing management, and the group with experience of infection education showed the highest number in terms of awareness of ultrasound equipment hygiene, and the group with less than college education showed the highest number in terms of performance of ultrasound equipment hygiene. The difference was statistically significant. Based on the results of this study, performance was lower than awareness in general. This result indicates that the degree of performance is inadequate. Therefore, it can be concluded that individuals need to change their perception of personal hygiene and take interest in it through infection education.

  11. Mesoporous Structure Control of Silica in Room-Temperature Synthesis under Basic Conditions

    Directory of Open Access Journals (Sweden)

    Jeong Wook Seo

    2015-01-01

    Full Text Available Various types of mesoporous silica, such as continuous cubic-phase MCM-48, hexagonal-phase MCM-41, and layer-phase spherical silica particles, have been synthesized at room temperature using cetyltrimethylammonium bromide as a surfactant, ethanol as a cosurfactant, tetraethyl orthosilicate as a silica precursor, and ammonia as a condensation agent. Special care must be taken both in the filtering of the resultant solid products and in the drying process. In the drying process, further condensation of the silica after filtering was induced. As the surfactant and cosurfactant concentrations in the reaction mixture increased and the NH3 concentration decreased, under given conditions, continuous cubic MCM-48 and layered silica became the dominant phases. A cooperative synthesis mechanism, in which both the surfactant and silica were involved in the formation of mesoporous structures, provided a good explanation of the experimental results.

  12. Controllable synthesis and catalytic activity of SnO_2 nanostructures at room temperature

    Institute of Scientific and Technical Information of China (English)

    ZHAO Qing-rui

    2009-01-01

    SnO_2 hollow spheres and rod bundles were prepared using SnSO_4 as raw material and sodium dodecyl benzenesulfonate and poly(vinyl pyrrolidone) as templates at room temperature through oxidation-crystallization of colloidal spheres in different systems. The products were characterized with X-ray diffractometer, X-ray photoelectron spectrometer, transmission electron microscope and scanning electron microscope. Meanwhile, the catalytic performance of the SnO_2 hollow spheres and rod bundles toward CO oxidation was studied. The result indicates that SnO_2 hollow spheres with the uniform size exhibit a better catalytic activity toward CO oxidation, suggesting that the morphology of the materials has exerted a noticeable influence on the catalytic performance.

  13. Gesture-Controlled Interface for Contactless Control of Various Computer Programs with a Hooking-Based Keyboard and Mouse-Mapping Technique in the Operating Room.

    Science.gov (United States)

    Park, Ben Joonyeon; Jang, Taekjin; Choi, Jong Woo; Kim, Namkug

    2016-01-01

    We developed a contactless interface that exploits hand gestures to effectively control medical images in the operating room. We developed an in-house program called GestureHook that exploits message hooking techniques to convert gestures into specific functions. For quantitative evaluation of this program, we used gestures to control images of a dynamic biliary CT study and compared the results with those of a mouse (8.54 ± 1.77 s to 5.29 ± 1.00 s; p < 0.001) and measured the recognition rates of specific gestures and the success rates of tasks based on clinical scenarios. For clinical applications, this program was set up in the operating room to browse images for plastic surgery. A surgeon browsed images from three different programs: CT images from a PACS program, volume-rendered images from a 3D PACS program, and surgical planning photographs from a basic image viewing program. All programs could be seamlessly controlled by gestures and motions. This approach can control all operating room programs without source code modification and provide surgeons with a new way to safely browse through images and easily switch applications during surgical procedures.

  14. Virtual Visit to the ATLAS Control Room by the Genova University

    CERN Multimedia

    2013-01-01

    Manuel Peleteiro is an outstanding school in Galicia and in Spain. We form our approximately 1600 students from the ages of 3-18 in educational excellence, in which the level we achieve in science subjects is high. At present, due to the growth of cutting-edge technology, we can fly from our new campus inaugurated in 2009 to the ATLAS detector and CERN facilities to have our students take part in the latest achievements in modern physics research accomplished by CERN and to be exposed to their enthusiasm, boldness and talent which has taken them to advance in the knowledge of the structure of matter and the origin of the universe. http://atlas-live-virtual-visit.web.cern.ch/atlas-live-virtual-visit/2013/SantiagoComp-2013.html

  15. Thermal room modelling adapted to the test of HVAC control systems; Modele de zone adapte aux essais de regulateurs de systemes de chauffage et de climatisation

    Energy Technology Data Exchange (ETDEWEB)

    Riederer, P.

    2002-01-15

    Room models, currently used for controller tests, assume the room air to be perfectly mixed. A new room model is developed, assuming non-homogeneous room conditions and distinguishing between different sensor positions. From measurement in real test rooms and detailed CFD simulations, a list of convective phenomena is obtained that has to be considered in the development of a model for a room equipped with different HVAC systems. The zonal modelling approach that divides the room air into several sub-volumes is chosen, since it is able to represent the important convective phenomena imposed on the HVAC system. The convective room model is divided into two parts: a zonal model, representing the air at the occupant zone and a second model, providing the conditions at typical sensor positions. Using this approach, the comfort conditions at the occupant zone can be evaluated as well as the impact of different sensor positions. The model is validated for a test room equipped with different HVAC systems. Sensitivity analysis is carried out on the main parameters of the model. Performance assessment and energy consumption are then compared for different sensor positions in a room equipped with different HVAC systems. The results are also compared with those obtained when a well-mixed model is used. A main conclusion of these tests is, that the differences obtained, when changing the position of the controller's sensor, is a function of the HVAC system and controller type. The differences are generally small in terms of thermal comfort but significant in terms of overall energy consumption. For different HVAC systems the cases are listed, in which the use of a simplified model is not recommended. (author)

  16. Assessing Controls on the Geometry and Dimensions of Modern Barrier Islands

    Science.gov (United States)

    Mulhern, J.; Johnson, C. L.; Martin, J. M.

    2015-12-01

    Barrier islands are highly ephemeral features, shaped by wave, tide, and storm energy. The processes that govern the size, shape, and motion of barrier islands are not well constrained, yet central to coastal dynamics. While the global distribution of barrier islands has been mapped and assessed, there is little consensus on the forces controlling barrier island formation, motion, or preservation. This study presents a new semi-global database of modern barrier islands to better understand their morphology and spatial distribution. We have mapped, in Google Earth, the subaerial extent of >350 barrier islands and spits, measuring spatial characteristic such as exposed area, perimeter, length, and width. These objects are cross-referenced with parameters that potentially control morphology, including tidal range, wave height, climate, distance from the continental shelf, proximity to fluvial output, and tectonic setting. This approach provides a more optimal framework to assess controls on coastal features, including barrier island morphology, and to investigate potential geometric scaling relationships. Preliminary analysis shows trends in the spatial characteristics of barrier islands. There is a strong linear relationship between the perimeter and length (y= -0.59 + 0.42x, R2=0.95). Linear trends also relate length to area when the data are separated by tidal range to wave height ratio. Assessment of barrier island shape supports the hypothesis of Hayes (1979) that barrier islands in wave-dominated settings are long and linear while those in mixed energy setting are more rounded. The barrier islands of the Texas Gulf of Mexico are larger than the global average for the database, with distinctly longer length values (41.16 km vs. 15.77 km respectively) and larger areas (103.81 km2 vs. 42.14 km2 respectively). Initial assessment shows that tidal range and wave height are primary controls barrier island dimensions. Future work will consider climate, latitude, fluvial

  17. Nutrient and temperature controls on modern carbonate production: An example from the Gulf of California, Mexico

    Science.gov (United States)

    Halfar, Jochen; Godinez-Orta, Lucio; Mutti, Maria; Valdez-Holguín, José E.; Borges, Jose M.

    2004-03-01

    In addition to salinity and temperature, nutrient concentrations in surface waters are known to have a significant impact on distribution of carbonate-producing biota, but have never been quantitatively evaluated against different temperatures along a latitudinal transect. The western coast of the Gulf of California, Mexico, presents a natural laboratory for investigating the influence of oceanographic parameters such as salinity, temperature, and chlorophyll a, a proxy for nutrients, on the composition of a range of modern heterozoan and photozoan carbonate environments along a north-south latitudinal gradient spanning the entire warm-temperate realm (29°N 23°N). Chlorophyll a, measured in situ at half-hour resolution, is highly variable throughout the year due to short-term upwelling, and increases significantly from the southern to northern Gulf of California. Salinity, in contrast, fluctuates little and remains at an average of 35‰. From south to north, carbonate production ranges from oligotrophic-mesotrophic, coral reef dominated shallow-water areas (minimum temperature 18.6 °C) through mesotrophic-eutrophic, red algal dominated, inner-shelf carbonate production in the central gulf (minimum temperature 16 °C), and to molluscan-bryozoan, eutrophic inner- to outer-shelf environments (minimum temperature 13.7 °C). The Gulf of California data, supplemented with oceanographic and compositional information from a database compiled from a spectrum of modern carbonate systems worldwide, demonstrates the significance of nutrient control in the formation of heterozoan, photozoan, and transitional heterozoan-photozoan carbonate systems and serves as a basis for more accurately interpreting fossil carbonates.

  18. A study on associations of Korean sample group for colors applied to the nuclear power plant control room

    Energy Technology Data Exchange (ETDEWEB)

    Oh, In Seok; Lee, Jung Woon; Lee, Yong Hee; Lee, Hyun Chul [Korea Atomic Energy Research Institute, Taejeon (Korea); Lee, Dhong Ha [Suwon University, Whasung (Korea)

    2002-05-01

    Colors are widely used to warn risk levels and to attract attention of the public. Korea Standard Nuclear Reactor Control Room (KSNRCR) also uses several colors to differentiate warnings, priorities, status, borders, and messages based on the HF010 guideline. However the previous studies showed that the general public not engaged in a specific job domain had different associations of colors as regulated in the standards or the guidelines. It is also expected that the general public not engaged in nuclear power plant industry will have different color association system from the color coding system applied to the KSNRCR. So, this study was performed to show whether there is any difference between color association of a sample Korean group and the color meanings specified in the HF010 guideline. The general public not engaged in the nuclear power plant industry have no idea of the color usage in the nuclear control room. So we converted the specific color usage situation into similar but general situations. In questionnaire, we gave subjects the general situation where color coding is appled and alternative colors which were applied to the HF010 guidelines. And we asked the subjects to choose the colors proper to the situation and to rank the colors according to the degree of suitability. A hundred college students participated in the experiment. 10 refs., 7 tabs. (Author)

  19. Room Acoustics

    Science.gov (United States)

    Kuttruff, Heinrich; Mommertz, Eckard

    The traditional task of room acoustics is to create or formulate conditions which ensure the best possible propagation of sound in a room from a sound source to a listener. Thus, objects of room acoustics are in particular assembly halls of all kinds, such as auditoria and lecture halls, conference rooms, theaters, concert halls or churches. Already at this point, it has to be pointed out that these conditions essentially depend on the question if speech or music should be transmitted; in the first case, the criterion for transmission quality is good speech intelligibility, in the other case, however, the success of room-acoustical efforts depends on other factors that cannot be quantified that easily, not least it also depends on the hearing habits of the listeners. In any case, absolutely "good acoustics" of a room do not exist.

  20. Is single room hospital accommodation associated with differences in healthcare-associated infection, falls, pressure ulcers or medication errors? A natural experiment with non-equivalent controls

    Science.gov (United States)

    Maben, Jill; Murrells, Trevor; Griffiths, Peter

    2016-01-01

    Objectives A wide range of patient benefits have been attributed to single room hospital accommodation including a reduction in adverse patient safety events. However, studies have been limited to the US with limited evidence from elsewhere. The aim of this study was to assess the impact on safety outcomes of the move to a newly built all single room acute hospital. Methods A natural experiment investigating the move to 100% single room accommodation in acute assessment, surgical and older people’s wards. Move to 100% single room accommodation compared to ‘steady state’ and ‘new build’ control hospitals. Falls, pressure ulcer, medication error, meticillin-resistant Staphylococcus aureus and Clostridium difficile rates from routine data sources were measured over 36 months. Results Five of 15 time series in the wards that moved to single room accommodation revealed changes that coincided with the move to the new all single room hospital: specifically, increased fall, pressure ulcer and Clostridium difficile rates in the older people’s ward, and temporary increases in falls and medication errors in the acute assessment unit. However, because the case mix of the older people’s ward changed, and because the increase in falls and medication errors on the acute assessment ward did not last longer than six months, no clear effect of single rooms on the safety outcomes was demonstrated. There were no changes to safety events coinciding with the move at the new build control site. Conclusion For all changes in patient safety events that coincided with the move to single rooms, we found plausible alternative explanations such as case-mix change or disruption as a result of the re-organization of services after the move. The results provide no evidence of either benefit or harm from all single room accommodation in terms of safety-related outcomes, although there may be short-term risks associated with a move to single rooms. PMID:26811373

  1. Parent misperception of control in childhood/adolescent asthma: the Room to Breathe survey.

    Science.gov (United States)

    Carroll, W D; Wildhaber, J; Brand, P L P

    2012-01-01

    The aim of our study was to determine how often asthma control is achieved in children and adolescents, and how asthma affects parents' and children's daily lives. Interviews, including the childhood asthma control test (C-ACT), were conducted with 1,284 parents of asthmatic children (aged 4-15 yrs), as well as with the children themselves (aged 8-15 yrs; n=943), in Canada, Greece, Hungary, the Netherlands, South Africa and the UK. Parents reported mild asthma attacks at least weekly in 11% of children, and serious attacks (requiring oral corticosteroids or hospitalisation) at least annually in 35%. Although 73% of parents described their child's asthma as mild or intermittent, 40% of children/adolescents had C-ACT scores ≤ 19, indicating inadequate control, and only 14.7% achieved complete Global Initiative for Asthma (GINA)-defined control and just 9.2% achieved Scottish Intercollegiate Guidelines Network (SIGN)/British Thoracic Society (BTS)-defined control. Guideline-defined asthma control was significantly less common than well-controlled asthma using the C-ACT (pAsthma restricted the child's activities in 39% of families and caused lifestyle changes in 70%. Complete asthma control is uncommon in children worldwide. Guideline-defined control measures appear to be more stringent than those defined by C-ACT or families. Overall, parents underestimate their child's asthma severity and overestimate asthma control. This is a major potential barrier to successful asthma treatment in children.

  2. Room-temperature electronically-controlled ferromagnetism at the LaAlO₃/SrTiO₃ interface.

    Science.gov (United States)

    Bi, Feng; Huang, Mengchen; Ryu, Sangwoo; Lee, Hyungwoo; Bark, Chung-Wung; Eom, Chang-Beom; Irvin, Patrick; Levy, Jeremy

    2014-09-25

    Reports of emergent conductivity, superconductivity and magnetism have helped to fuel intense interest in the rich physics and technological potential of complex-oxide interfaces. Here we employ magnetic force microscopy to search for room-temperature magnetism in the well-studied LaAlO3/SrTiO3 system. Using electrical top gating to control the electron density at the oxide interface, we directly observe the emergence of an in-plane ferromagnetic phase as electrons are depleted from the interface. Itinerant electrons that are reintroduced into the interface align antiferromagnetically with the magnetization at first screening and then destabilizing it as the conductive regime is approached. Repeated cycling of the gate voltage results in new, uncorrelated magnetic patterns. This newfound control over emergent magnetism at the interface between two non-magnetic oxides portends a number of important technological applications.

  3. Room-temperature electronically-controlled ferromagnetism at the LaAlO3/SrTiO3 interface

    Science.gov (United States)

    Bi, Feng; Huang, Mengchen; Ryu, Sangwoo; Lee, Hyungwoo; Bark, Chung-Wung; Eom, Chang-Beom; Irvin, Patrick; Levy, Jeremy

    2014-09-01

    Reports of emergent conductivity, superconductivity and magnetism have helped to fuel intense interest in the rich physics and technological potential of complex-oxide interfaces. Here we employ magnetic force microscopy to search for room-temperature magnetism in the well-studied LaAlO3/SrTiO3 system. Using electrical top gating to control the electron density at the oxide interface, we directly observe the emergence of an in-plane ferromagnetic phase as electrons are depleted from the interface. Itinerant electrons that are reintroduced into the interface align antiferromagnetically with the magnetization at first screening and then destabilizing it as the conductive regime is approached. Repeated cycling of the gate voltage results in new, uncorrelated magnetic patterns. This newfound control over emergent magnetism at the interface between two non-magnetic oxides portends a number of important technological applications.

  4. Parent misperception of control in childhood/adolescent asthma : the Room to Breathe survey

    NARCIS (Netherlands)

    Carroll, W. D.; Wildhaber, J.; Brand, P. L. P.

    2012-01-01

    The aim of our study was to determine how often asthma control is achieved in children and adolescents, and how asthma affects parents' and children's daily lives. Interviews, including the childhood asthma control test (C-ACT), were conducted with 1,284 parents of asthmatic children (aged 4-15 yrs)

  5. Parent misperception of control in childhood/adolescent asthma : the Room to Breathe survey

    NARCIS (Netherlands)

    Carroll, W. D.; Wildhaber, J.; Brand, P. L. P.

    The aim of our study was to determine how often asthma control is achieved in children and adolescents, and how asthma affects parents' and children's daily lives. Interviews, including the childhood asthma control test (C-ACT), were conducted with 1,284 parents of asthmatic children (aged 4-15

  6. Time dependent corrections to absolute gravity determinations in the establishment of modern gravity control

    Science.gov (United States)

    Dykowski, Przemyslaw; Krynski, Jan

    2015-04-01

    The establishment of modern gravity control with the use of exclusively absolute method of gravity determination has significant advantages as compared to the one established mostly with relative gravity measurements (e.g. accuracy, time efficiency). The newly modernized gravity control in Poland consists of 28 fundamental stations (laboratory) and 168 base stations (PBOG14 - located in the field). Gravity at the fundamental stations was surveyed with the FG5-230 gravimeter of the Warsaw University of Technology, and at the base stations - with the A10-020 gravimeter of the Institute of Geodesy and Cartography, Warsaw. This work concerns absolute gravity determinations at the base stations. Although free of common relative measurement errors (e.g. instrumental drift) and effects of network adjustment, absolute gravity determinations for the establishment of gravity control require advanced corrections due to time dependent factors, i.e. tidal and ocean loading corrections, atmospheric corrections and hydrological corrections that were not taken into account when establishing the previous gravity control in Poland. Currently available services and software allow to determine high accuracy and high temporal resolution corrections for atmospheric (based on digital weather models, e.g. ECMWF) and hydrological (based on hydrological models, e.g. GLDAS/Noah) gravitational and loading effects. These corrections are mostly used for processing observations with Superconducting Gravimeters in the Global Geodynamics Project. For the area of Poland the atmospheric correction based on weather models can differ from standard atmospheric correction by even ±2 µGal. The hydrological model shows the annual variability of ±8 µGal. In addition the standard tidal correction may differ from the one obtained from the local tidal model (based on tidal observations). Such difference at Borowa Gora Observatory reaches the level of ±1.5 µGal. Overall the sum of atmospheric and

  7. Evaluation of Sabine's formula on the prediction and control of reverberant noise in a modern LEED Platinum certified research building

    Science.gov (United States)

    Quinn-Vawter, Christopher

    The Powerhouse Energy Campus is a LEED Platinum certified research building located in Fort Collins, Colorado and is part of Colorado State University. Completed in 2014, the renovated interior of the Powerhouse consists largely of open floor plans with minimal closed rooms to allow the building's heating and cooling system to function. The open floor plan and use of interior building materials with hard surfaces created problematic noise levels for the office occupants as noise from laboratory spaces or offices could be heard throughout the building. This project provided a unique opportunity to evaluate the method available to most industrial hygienists to measure and predict reverberant noise: Sabine's Formula and the impulse noise method of reverberation measurement. Reverberation times (RT60) in five interior spaces ranging from 76 m3 to 5400 m3 were modeled using a Sabine's Formula model. The RT60 predictions were then compared to the reverberation times measured in each location, and reverberant noise treatments were designed for two rooms using the same models. The RT 60 times were taken again after the installation of the recommended treatments for two rooms. This allowed for the evaluation of both the modeling capabilities of Sabine's Formula and the practical industrial hygiene application of the equation to select effective acoustic treatments to control reverberant noise. The model performed well in room volumes 620 m3 and below, and would have likely performed better in the large volume rooms if they did not have such complex, open acoustic environments. The model was still slightly underestimating reverberation times at 620 m3 indicating that it would perform well in larger volume spaces, though this study was not able to identify the room volume at which Sabine's Formula begins to overestimate reverberation times. The RT60 time reductions in both the first floor classroom and the second floor conference room indicated that the reverberant noise

  8. Microbial mat controls on infaunal abundance and diversity in modern marine microbialites.

    Science.gov (United States)

    Tarhan, L G; Planavsky, N J; Laumer, C E; Stolz, J F; Reid, R P

    2013-09-01

    Microbialites are the most abundant macrofossils of the Precambrian. Decline in microbialite abundance and diversity during the terminal Proterozoic and early Phanerozoic has historically been attributed to the concurrent radiation of complex metazoans. Similarly, the apparent resurgence of microbialites in the wake of Paleozoic and Mesozoic mass extinctions is frequently linked to drastic declines in metazoan diversity and abundance. However, it has become increasing clear that microbialites are relatively common in certain modern shallow, normal marine carbonate environments-foremost the Bahamas. For the first time, we present data, collected from the Exuma Cays, the Bahamas, systematically characterizing the relationship between framework-building cyanobacteria, microbialite fabrics, and microbialite-associated metazoan abundance and diversity. We document the coexistence of diverse microbialite and infaunal metazoan communities and demonstrate that the predominant control upon both microbialite fabric and metazoan community structure is microbial mat type. These findings necessitate that we rethink prevalent interpretations of microbialite-metazoan interactions and imply that microbialites are not passive recipients of metazoan-mediated alteration. Additionally, this work provides support for the theory that certain Precambrian microbialites may have been havens of early complex metazoan life, rather than bereft of metazoans, as has been traditionally envisaged. © 2013 John Wiley & Sons Ltd.

  9. History and modern applications of nano-composite materials carrying GA/cm2 current density due to a Bose-Einstein Condensate at room temperature produced by Focused Electron Beam Induced Processing for many extraordinary novel technical applications

    Science.gov (United States)

    Koops, Hans W. P.

    2015-12-01

    The discovery of Focused Electron Beam Induced Processing and early applications of this technology led to the possible use of a novel nanogranular material “Koops-GranMat®” using Pt/C and Au/C material. which carries at room temperature a current density > 50 times the current density which high TC superconductors can carry. The explanation for the characteristics of this novel material is given. This fact allows producing novel products for many applications using Dual Beam system having a gas supply and X.Y.T stream data programming and not using GDSII layout pattern control software. Novel products are possible for energy transportation. -distribution.-switching, photon-detection above 65 meV energy for very efficient energy harvesting, for bright field emission electron sources used for vacuum electronic devices like amplifiers for HF electronics, micro-tubes, 30 GHz to 6 THz switching amplifiers with signal to noise ratio >10(!), THz power sources up to 1 Watt, in combination with miniaturized vacuum pumps, vacuum gauges, IR to THz detectors, EUV- and X-Ray sources. Since focusing electron beam induced deposition works also at low energy, selfcloning multibeam-production machines for field emitter lamps, displays, multi-beam - lithography, - imaging, and - inspection, energy harvesting, and power distribution with switches controlling field-emitter arrays for KA of currents but with < 100 V switching voltage are possible. Finally the replacement of HTC superconductors and its applications by the Koops-GranMat® having Koops-Pairs at room temperature will allow the investigation devices similar to Josephson Junctions and its applications now called QUIDART (Quantum interference devices at Room Temperature). All these possibilities will support a revolution in the optical, electric, power, and electronic technology.

  10. Calling all LEGO lovers! Add a mini control room to your collection

    CERN Multimedia

    Katarina Anthony

    2015-01-01

    The mini LHC Lego project launched in March (see here) now has almost 6,000 supporters - well on its way to the 10,000 votes needed for it to (hopefully!) hit store shelves. This week, the project added a new feature to its line: a mini control centre! The new LEGO Control centre, featuring operators "Kerstin" and "Marco".   The mini LHC project is the brainchild of ATLAS PhD student Nathan Readioff, who designed Lego replicas of the LHC and the ALICE, ATLAS, CMS and LHCb experiments on a micro scale. Each detector model is small enough to fit in the palm of your hand but crammed with detailed internal systems revealed by cutaway walls. Every major detector component is represented by a Lego piece. Now, Nathan has created a control centre to complement the mini LHC project. This would be an add-on feature for Lego’s consideration, should they decide to develop the accelerator into a box set. “The control centre is ...

  11. Virtual Visit to the ATLAS Control Room during Researchers Night by Institute of Nuclear Physics Polish Academy of Sciences, Cracow

    CERN Multimedia

    ATLAS Experiment

    2012-01-01

    We invite our "6-th Ma?opolska Researchers Night" guests for Virtual Visits in ATLAS Control Room. They could ask Polish scientists and experts during a lecture "How a mass is created - the Higgs boson discovery" to be given by dr Anna Kaczmarska. "Ma?opolska Researchers Night" is a part of European Researchers Night events to be held in more than 200 cities. Institute of Nuclear Physics Polish Academy of Sciences invites Cracow citizens and tourists visiting our town to its laboratories and to the "Science Garden" formed, especially for this event, in front of the main building. Visitors will have an unique opportunity to discuss science problems with researches and students. Wide range of demonstrations of interesting activities performed in our institute will be presented, these include among others: - AIC 144 Cyclotron with hadrons' therapy facility for eye treatment - Dosimetry and environmental pollution monitoring - Large Hadron Collider experiments - Van de Graff linear accelerator with proton micro b...

  12. Fast, high-fidelity, all-optical and dynamically-controlled polarization gate using room-temperature atomic vapor

    Science.gov (United States)

    Li, Runbing; Zhu, Chengjie; Deng, L.; Hagley, E. W.

    2014-10-01

    We demonstrate a fast, all-optical polarization gate in a room-temperature atomic medium. Using a Polarization-Selective-Kerr-Phase-Shift (PSKPS) technique, we selectively write a π phase shift to one circularly-polarized component of a linearly-polarized input signal field. The output signal field maintains its original strength but acquires a 90° linear polarization rotation, demonstrating fast, high-fidelity, dynamically-controlled polarization gate operation. The intensity of the polarization-switching field used in this PKSPK-based polarization gate operation is only 2 mW/cm2, which would be equivalent to 0.5 nW of light power (λ = 800 nm) confined in a typical commercial photonic hollow-core fiber. This development opens a realm of possibilities for potential future extremely low light level telecommunication and information processing systems.

  13. Investigation of the impact of main control room digitalization on operators cognitive reliability in nuclear power plants.

    Science.gov (United States)

    Zhou, Yong; Mu, Haiying; Jiang, Jianjun; Zhang, Li

    2012-01-01

    Currently, there is a trend in nuclear power plants (NPPs) toward introducing digital and computer technologies into main control rooms (MCRs). Safe generation of electric power in NPPs requires reliable performance of cognitive tasks such as fault detection, diagnosis, and response planning. The digitalization of MCRs has dramatically changed the whole operating environment, and the ways operators interact with the plant systems. If the design and implementation of the digital technology is incompatible with operators' cognitive characteristics, it may have negative effects on operators' cognitive reliability. Firstly, on the basis of three essential prerequisites for successful cognitive tasks, a causal model is constructed to reveal the typical human performance issues arising from digitalization. The cognitive mechanisms which they impact cognitive reliability are analyzed in detail. Then, Bayesian inference is used to quantify and prioritize the influences of these factors. It suggests that interface management and unbalanced workload distribution have more significant impacts on operators' cognitive reliability.

  14. Transient stability enhancement of modern power grid using predictive Wide-Area Monitoring and Control

    Science.gov (United States)

    Yousefian, Reza

    This dissertation presents a real-time Wide-Area Control (WAC) designed based on artificial intelligence for large scale modern power systems transient stability enhancement. The WAC using the measurements available from Phasor Measurement Units (PMUs) at generator buses, monitors the global oscillations in the system and optimally augments the local excitation system of the synchronous generators. The complexity of the power system stability problem along with uncertainties and nonlinearities makes the conventional modeling non-practical or inaccurate. In this work Reinforcement Learning (RL) algorithm on the benchmark of Neural Networks (NNs) is used to map the nonlinearities of the system in real-time. This method different from both the centralized and the decentralized control schemes, employs a number of semi-autonomous agents to collaborate with each other to perform optimal control theory well-suited for WAC applications. Also, to handle the delays in Wide-Area Monitoring (WAM) and adapt the RL toward the robust control design, Temporal Difference (TD) is proposed as a solver for RL problem or optimal cost function. However, the main drawback of such WAC design is that it is challenging to determine if an offline trained network is valid to assess the stability of the power system once the system is evolved to a different operating state or network topology. In order to address the generality issue of NNs, a value priority scheme is proposed in this work to design a hybrid linear and nonlinear controllers. The algorithm so-called supervised RL is based on mixture of experts, where it is initialized by linear controller and as the performance and identification of the RL controller improves in real-time switches to the other controller. This work also focuses on transient stability and develops Lyapunov energy functions for synchronous generators to monitor the stability stress of the system. Using such energies as a cost function guarantees the convergence

  15. Communications Dashboard (Control Rooms Take a Cue from Facebook), Chapter 1

    Science.gov (United States)

    Scott, David w.

    2013-01-01

    Papers published via IEEE and AIAA conferences have presented an overview of how social media could benefit NASA working environments in general and proposed three specific social applications to benefit space flight control operations. One of them, Communications Dashboard, would help a real time flight controller keep up with both the "big picture" and significant details of operations via a cohesive interface similar to those of social networking services (SNS). Instead of recreational social features, "CommDash" would support functions like console logging, categorized and threaded text chat streams with enhanced accountability and graphics display features, high-level status displays driven by telemetry or other events, and an on-screen hailing function for requesting voice or text stream conversation. Moving certain voice conversations to text streams would reduce confusion and stress in two ways. Within text conversations, there would be far less repetition of content since text conversations have visual persistence and are reviewable instantly, e.g., there s no need to brief new participants to a discussion -- they just read what s already there. Remaining voice traffic would stand out more clearly, and quieter voice loops means fewer "say again" calls and less distraction from visual and mental tasks, thus less stress. (Most flight controllers monitor 4 or 5 voice loops at once.) Links could be created from console log entries to chat selections so that underlying details are readily available yet unobtrusive. This would reduce the confusion that rises from having multiple and sometimes divergent copies of the same information due to cut/copy and paste operations, attachments, and asynchronous editing. This concept could apply to a plethora of real time control environments and to other settings with lots of information juggling. This paper explores the dashboard concept in further detail and chronicles the first phase of a NASA IT Labs (Information

  16. Communications dashboard (control rooms, take a cue from Facebook® !) Chapter 1

    Science.gov (United States)

    Scott, David W.

    Papers published via IEEE and AIAA conferences have presented an overview of how social media could benefit NASA working environments in general [1] and proposed three specific social applications to benefit space flight control operations [2]. One of them, Communications Dashboard, would help a real time flight controller keep up with both the “ big picture” and significant details of operations via a cohesive interface similar to those of social networking services (SNS). Instead of recreational social features, “ CommDash” would support functions like console logging, categorized and threaded text chat streams with enhanced accountability and graphics display features, high-level status displays driven by telemetry or other events, and an on-screen hailing function for requesting voice or text stream conversation. Moving certain voice conversations to text streams would reduce confusion and stress in two ways. Within text conversations, there would be far less repetition of content since text conversations have visual persistence and are reviewable instantly, e.g., there's no need to brief new participants to a discussion - they just read what's already there. Remaining voice traffic would stand out more clearly, and quieter voice loops means fewer “ say again” calls and less distraction from visual and mental tasks, thus less stress. (Most flight controllers monitor 4 or 5 voice loops at once.) Links could be created from console log entries to chat selections so that underlying details are readily available yet unobtrusive. This would reduce the confusion that rises from having multiple and sometimes divergent copies of the same information due to cut/copy and paste operations, attachments, and asynchronous editing. This concept could apply to a plethora of real time control environments and to other settings with lots of information juggling. This paper explores the dashboard concept in further detail and chronic- es the first phase of a NASA IT

  17. An efficient on-board metal-free nanocatalyst for controlled room temperature hydrogen production.

    Science.gov (United States)

    Santra, Saswati; Das, Debanjan; Das, Nirmalya Sankar; Nanda, Karuna Kar

    2017-04-01

    Positively charged functionalized carbon nanodots (CNDs) with a variety of different effective surface areas (ESAs) are synthesized via a cheap and time effective microwave method and applied for the generation of hydrogen via hydrolysis of sodium borohydride. To the best of our knowledge, this is the first report of metal-free controlled hydrogen generation. Our observation is that a positively charged functional group is essential for the hydrolysis for hydrogen production, but the overall activity is found to be enhanced with the ESA. A maximum value of 1066 ml g(-1) min(-1) as the turnover frequency is obtained which is moderate in comparison to other catalysts. However, the optimum activation energy is found to be 22.01 kJ mol(-1) which is comparable to well-known high cost materials like Pt and Ru. All of the samples showed good reusability and 100% conversion even after the 10th cycle. The effect of H(+) and OH(-) is also studied to control the on-board and on-demand hydrogen production ("on-off switching"). It is observed that H2 production decreases inversely with NaOH concentration and ceases completely when 10(-1) M NaOH is added. With the addition of HCl, H2 production can be initiated again, which confirms the on/off control over production.

  18. Modern isotope hydrology and controls on δD of plant leaf waxes at Lake El'gygytgyn, NE Russia

    Directory of Open Access Journals (Sweden)

    K. M. K. Wilkie

    2013-02-01

    Full Text Available Stable isotope data from lipid biomarkers and diatom silica recovered from lake sediment cores hold great promise for paleoclimate and paleohydrological reconstructions. However, these records rely on accurate calibration with modern precipitation and hydrologic processes and only limited data exist on the controls on the δD values for n-alkanoic acids from plant leaf waxes. Here we investigate the stable isotopic composition of modern precipitation, streams, lake water and ice cover, and use these data to constrain isotope systematics of the Lake El'gygytgyn Basin hydrology. Compound-specific hydrogen isotope ratios determined from n-alkanoic acids from modern vegetation are compared with modern precipitation and lake core top sediments. Multi-species net (apparent fractionation values between source water (precipitation and modern vegetation (e.g., ϵwax/precip mean value is −107 ± 12‰ agree with previous results and suggest a consistent offset between source waters and the δD values of alkanoic acids. We conclude that although there may be some bias towards a winter precipitation signal, overall δD values from leaf wax n-alkanoic acids record annual average precipitation within the El'gygytgyn Basin. A net fractionation calculated for 200-yr-integrated lake sediments yields ϵ30/precip = −96 ± 8‰ and can provide robust net "apparent" fractionation to be used in future paleohydrological reconstructions.

  19. Developing a taxonomy of coordination behaviours in nuclear power plant control rooms during emergencies.

    Science.gov (United States)

    Wang, Dunxing; Gao, Qin; Li, Zhizhong; Song, Fei; Ma, Liang

    2017-05-19

    This study aims to develop a taxonomy of coordination behaviours during emergencies in nuclear power plants (NPPs). We summarised basic coordination behaviours from literature in aviation, health care and nuclear field and identified coordination behaviours specific to the nuclear domain by interviewing and surveying control crew operators. The established taxonomy includes 7 workflow stages and 24 basic coordination behaviours. To evaluate the reliability and feasibility of the taxonomy, we analysed 12 videos of operators' training sessions by coding coordination behaviours with the taxonomy and the inter-rater reliability was acceptable. Further analysis of the frequency, the duration and the direction of the coordination behaviours revealed four coordination problems. This taxonomy provides a foundation of systematic observation of coordination behaviours among NPP crews, advances researchers' understanding of the coordination mechanism during emergencies in NPPs and facilitate the possibility to deepen the understanding of the relationships between coordination behaviours and team performance. Practitioner Summary: A taxonomy of coordination behaviours during emergencies in nuclear power plants was developed. Reliability and feasibility of the taxonomy was verified through the analysis of 12 training sessions. The taxonomy can serve as an observation system for analysis of coordination behaviours and help to identify coordination problems of control crews.

  20. Operation Room Infection Factors and Control%手术室感染因素及控制

    Institute of Scientific and Technical Information of China (English)

    姜丽; 周静

    2014-01-01

    The postoperative infection of patients means that the threat to life, so to prevent postoperative infection has become the guarantee of human life, an important task to promote the rehabilitation of patients and medical development. In order to reduce the infection rate of operation, improve the quality of medical treatment, the operation infection factors analysis. The results show that: the infection factors although many, but in general the main or operation contact and air bacteria through various means of land caused by operation wound infection in operation room, so is the key to control [1] infection, so the scientific management of operation room, take comprehensive measures and dynamic bacteriological monitoring is the fundamental way to reduce operation incision infection. Ensure work quality is the key to operation room infection reduce all kinds of operation after operation.%术后感染对患者意味着生命的威胁,因此防止术后感染已经成为当今保障人类生命,促进患者康复和医学发展的一个重大课题。为降低手术感染率,提高医疗质量,对手术感染因素进行分析。结果表明:感染因素虽然很多,但总的来说主要还是手术的接触传播和空气浮游菌通过各种途径降落于手术创面而引起的感染,所以手术室是控制切口感染的关键[1],因此对手术室进行科学管理,采取综合预防措施和动态细菌学监测是降低手术切口感染的根本途径。保证手术室工作质量是减少各类手术术后感染的关键。

  1. Control of harmful hydrocarbon species in the exhaust of modern advanced GDI engines

    Science.gov (United States)

    Hasan, A. O.; Abu-jrai, A.; Turner, D.; Tsolakis, A.; Xu, H. M.; Golunski, S. E.; Herreros, J. M.

    2016-03-01

    A qualitative and quantitative analysis of toxic but currently non-regulated hydrocarbon compounds ranging from C5-C11, before and after a zoned three-way catalytic converter (TWC) in a modern gasoline direct injection (GDI) engine has been studied using gas chromatography-mass spectrometry (GC-MS). The GDI engine has been operated under conventional and advanced combustion modes, which result in better fuel economy and reduced levels of NOx with respect to standard SI operation. However, these fuel-efficient conditions are more challenging for the operation of a conventional TWC, and could lead to higher level of emissions released to the environment. Lean combustion leads to the reduction in pumping losses, fuel consumption and in-cylinder emission formation rates. However, lean HCCI will lead to high levels of unburnt HCs while the presence of oxygen will lower the TWC efficiency for NOx control. The effect on the catalytic conversion of the hydrocarbon species of the addition of hydrogen upstream the catalyst has been also investigated. The highest hydrocarbon engine-out emissions were produced for HCCI engine operation at low engine load operation. The catalyst was able to remove most of the hydrocarbon species to low levels (below the permissible exposure limits) for standard and most of the advanced combustion modes, except for naphthalene (classified as possibly carcinogenic to humans by the International Agency for Research on Cancer) and methyl-naphthalene (which has the potential to cause lung damage). However, when hydrogen was added upstream of the catalyst, the catalyst conversion efficiency in reducing methyl-naphthalene and naphthalene was increased by approximately 21%. This results in simultaneous fuel economy and environmental benefits from the effective combination of advanced combustion and novel aftertreatment systems.

  2. Ultrafast optical control of terahertz surface plasmons in subwavelength hole-arrays at room temperature

    Energy Technology Data Exchange (ETDEWEB)

    Azad, Abul Kalam [Los Alamos National Laboratory; Chen, Hou - Tong [Los Alamos National Laboratory; Taylor, Antoinette [Los Alamos National Laboratory; O' Hara, John [Los Alamos National Laboratory

    2010-12-10

    Extraordinary optical transmission through subwavelength metallic hole-arrays has been an active research area since its first demonstration. The frequency selective resonance properties of subwavelength metallic hole arrays, generally known as surface plasmon polaritons, have potential use in functional plasmonic devices such as filters, modulators, switches, etc. Such plasmonic devices are also very promising for future terahertz applications. Ultrafast switching or modulation of the resonant behavior of the 2-D metallic arrays in terahertz frequencies is of particular interest for high speed communication and sensing applications. In this paper, we demonstrate optical control of surface plasmon enhanced resonant terahertz transmission in two-dimensional subwavelength metallic hole arrays fabricated on gallium arsenide based substrates. Optically pumping the arrays creates a conductive layer in the substrate reducing the terahertz transmission amplitude of both the resonant mode and the direct transmission. Under low optical fluence, the terahertz transmission is more greatly affected by resonance damping than by propagation loss in the substrate. An ErAs:GaAs nanoisland superlattice substrate is shown to allow ultrafast control with a switching recovery time of {approx}10 ps. We also present resonant terahertz transmission in a hybrid plasmonic film comprised of an integrated array of subwavelength metallic islands and semiconductor holes. A large dynamic transition between a dipolar localized surface plasmon mode and a surface plasmon resonance near 0.8 THz is observed under near infrared optical excitation. The reversal in transmission amplitude from a stopband to a passband and up to {pi}/2 phase shift achieved in the hybrid plasmonic film make it promising in large dynamic phase modulation, optical changeover switching, and active terahertz plasmonics.

  3. Logistički kontroling u savremenim logističkim sistemima / Logistic controlling in modern logistic systems

    Directory of Open Access Journals (Sweden)

    Aleksandar Cakić

    2003-01-01

    Full Text Available U raduje data definicija logističkog kontrolinga u logističkim sistemima Prikazane su njegove osnovne funkcije, kao i mesto i uloga u upravljanju savremenim logističkim sistemima. Pregledno je prikazano kako pojedini autori definišu pojam i funkcije logističkog kontrolinga u savremenim logističkim sistemima. / In this paper a definition of logistic controlling in logistic systems has been given. The basic functions of logistic controlling are shown as well as its place and role in managing modern logistic systems. It is clearly shown how some other authors define the notion and the functions of logistic controlling in modern logistic systems.

  4. Microorganisms in Confined Habitats: Microbial Monitoring and Control of Intensive Care Units, Operating Rooms, Cleanrooms and the International Space Station.

    Science.gov (United States)

    Mora, Maximilian; Mahnert, Alexander; Koskinen, Kaisa; Pausan, Manuela R; Oberauner-Wappis, Lisa; Krause, Robert; Perras, Alexandra K; Gorkiewicz, Gregor; Berg, Gabriele; Moissl-Eichinger, Christine

    2016-01-01

    Indoor environments, where people spend most of their time, are characterized by a specific microbial community, the indoor microbiome. Most indoor environments are connected to the natural environment by high ventilation, but some habitats are more confined: intensive care units, operating rooms, cleanrooms and the international space station (ISS) are extraordinary living and working areas for humans, with a limited exchange with the environment. The purposes for confinement are different: a patient has to be protected from infections (intensive care unit, operating room), product quality has to be assured (cleanrooms), or confinement is necessary due to extreme, health-threatening outer conditions, as on the ISS. The ISS represents the most secluded man-made habitat, constantly inhabited by humans since November 2000 - and, inevitably, also by microorganisms. All of these man-made confined habitats need to be microbiologically monitored and controlled, by e.g., microbial cleaning and disinfection. However, these measures apply constant selective pressures, which support microbes with resistance capacities against antibiotics or chemical and physical stresses and thus facilitate the rise of survival specialists and multi-resistant strains. In this article, we summarize the available data on the microbiome of aforementioned confined habitats. By comparing the different operating, maintenance and monitoring procedures as well as microbial communities therein, we emphasize the importance to properly understand the effects of confinement on the microbial diversity, the possible risks represented by some of these microorganisms and by the evolution of (antibiotic) resistances in such environments - and the need to reassess the current hygiene standards.

  5. Microorganisms in confined habitats: Microbial monitoring and control of intensive care units, operating rooms, cleanrooms and the International Space Station

    Directory of Open Access Journals (Sweden)

    Maximilian Mora

    2016-10-01

    Full Text Available Indoor environments, where people spend most of their time, are characterized by a specific microbial community, the indoor microbiome. Most indoor environments are connected to the natural environment by high ventilation, but some habitats are more confined: intensive care units, operating rooms, cleanrooms and the international space station (ISS are extraordinary living and working areas for humans, with a limited exchange with the environment. The purposes for confinement are different: a patient has to be protected from infections (intensive care unit, operating room, product quality has to be assured (cleanrooms, or confinement is necessary due to extreme, health-threatening outer conditions, as on the ISS. The ISS represents the most secluded man-made habitat, constantly inhabited by humans since November 2000 – and, inevitably, also by microorganisms. All of these man-made confined habitats need to be microbiologically monitored and controlled, by e.g. microbial cleaning and disinfection. However, these measures apply constant selective pressures, which support microbes with resistance capacities against antibiotics or chemical and physical stresses and thus facilitate the rise of survival specialists and multi-resistant strains. In this article, we summarize the available data on the microbiome of aforementioned confined habitats. By comparing the different operating, maintenance and monitoring procedures as well as microbial communities therein, we emphasize the importance to properly understand the effects of confinement on the microbial diversity, the possible risks represented by some of these microorganisms and by the evolution of (antibiotic resistances in such environments - and the need to reassess the current hygiene standards.

  6. Reversible strain control of magnetic anisotropy in magnetoelectric heterostructures at room temperature

    Science.gov (United States)

    Staruch, Margo; Gopman, Daniel B.; Iunin, Yury L.; Shull, Robert D.; Cheng, Shu Fan; Bussmann, Konrad; Finkel, Peter

    2016-11-01

    The ability to tune both magnetic and electric properties in magnetoelectric (ME) composite heterostructures is crucial for multiple transduction applications including energy harvesting or magnetic field sensing, or other transduction devices. While large ME coupling achieved through interfacial strain-induced rotation of magnetic anisotropy in magnetostrictive/piezoelectric multiferroic heterostructures has been demonstrated, there are presently certain restrictions for achieving a full control of magnetism in an extensive operational dynamic range, limiting practical realization of this effect. Here, we demonstrate the possibility of generating substantial reversible anisotropy changes through induced interfacial strains driven by applied electric fields in magnetostrictive thin films deposited on (0 1 1)-oriented domain-engineered ternary relaxor ferroelectric single crystals with extended temperature and voltage ranges as compared to binary relaxors. We show, through a combination of angular magnetization and magneto-optical domain imaging measurements, that a 90° in-plane rotation of the magnetic anisotropy and propagation of magnetic domains with low applied electric fields under zero electric field bias are realized. To our knowledge, the present value attained for converse magnetoelectric coupling coefficient is the highest achieved in the linear piezoelectric regime and expected to be stable for a wide temperature range, thus representing a step towards practical ME transduction devices.

  7. Performance of the Operating Room Personnel in following of the standards of Infection Control in the Educational Hospitals of Yasuj University of Medical Sciences in 2009

    Directory of Open Access Journals (Sweden)

    A Rostaminejad

    2011-04-01

    Full Text Available Introduction & Objective: Surgical wound infection is one of the common nosocomial infections. During operation, members of the surgical team which are in contact with the tissue incision should observe the standards of infection control in the operating room since it has a great role in prevention and control of these infections. The present study aimed to determine the performance of the operating room personnel in observing the standards of infection control in educational hospitals of Yasuj University of Medical Sciences in 2009. Materials & Methods: Forty two operating room personnel participated in this cross-sectional analytic-descriptive study. A check list was used for unnoticeably collecting the data about the performance of personnel in respect of infection control standards at three different times. Their performances were classified into four levels (very weak, weak, moderate and good and the results were shown as absolute and relative frequency distribution. Data were analyzed using Chi-square and Fischer exact test by the SPSS software. Results: Performance of personnel in following the standards of infection control in this study was moderate. Conclusion: The results indicate that the participants of the study do not follow some of the standards of infection control in the operating rooms. Therefore, further activities of the committees of infection control and using of new antiseptic for surgical scrub are recommended.

  8. Investigation on the design of human-system interface for advanced nuclear plant control room

    Energy Technology Data Exchange (ETDEWEB)

    Chuang, C. F.; Chou, H. P. [Dept. of Engineering and System Science, National Tsing Hua Univ., Hsinchu Taiwan (China)

    2006-07-01

    The Lungmen Nuclear Power Project (LMNPP), under construction in Taiwan, consists of two GE Advanced Boiling Water Reactor (ABWR) units, each with 1350 MW electrical output. Major Human-System Interfaces (HSIs) of LMNPP are different from traditional ones. Video display units (VDUs) are the main human-system interface for operators to manipulate and to know the status of the equipment and plant information. Based upon NUREG-0711, the applicable human factors engineering (HFE) guideline in the design of HSIs has been adopted. An important aspect of the Lungmen HFE program has been the direct involvement of the end user, Taiwan Power Company (TPC), throughout the design development and implementation to ensure not only that the process for the design is compliant with the HFE principles, but also that the necessary displays, control, and alarms are provided to support the identified personnel tasks. This paper reviews the applicable HFE principles and verification and validation (V and V) processes in the design of HSIs for the advanced LMNPP. This paper also presents three investigated topics of the LMNPP HSI design development and implementation process. From the perspective of licensing concern and experience feedback, the focus of this paper is on the topics of validation with simulator, alarm auto reset, and VDU operational configuration strategy. The objectives of investigating the latter topic were to ensure the VDU operational configuration strategy, after appropriate V and V, achieves its goals of reinforcing operation discipline and distributing operator crew task assignments and workload during typical operations, and to confirm the need for an intensive training program that addresses the knowledge and skill requirements of the operators to meet the task characteristics and the responses of the plant processes. The results to date and implications for going forward from this process are also presented. (authors)

  9. Reading Room.

    Science.gov (United States)

    Fredericksen, Eric

    2002-01-01

    Describes how the Robin Hood foundation has teamed with architects to ensure that New York City's 650 schools have comprehensive and modern libraries. Offers brief descriptions of the first six library designs resulting from this public-private partnership. (EV)

  10. Development of an evaluation methodology for operator`s moving distance workload for the assessment of the layout and arrangement of nuclear power plant control rooms

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jeong Un; Seo, Sang Moon; Lee, Yong Hee; Cheon, Se Woo [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-07-01

    In this report, link analysis is discussed for the assessment of control room layout and arrangement, among the workload assessment methodologies using SACOM. A methodology developed for estimating operator`s moving distances based on modified link analysis is described, including its detail algorithm. This methodology was developed with the type and content of SACOM input information in consideration of not only software aspects but also easiness when the designer use this for control room layout and arrangement. 1 tab., 7 figs., 8 refs. (Author) .new.

  11. Electric field control of magnetization in Cu2O/porous anodic alumina hybrid structures at room temperature

    Science.gov (United States)

    Qi, L. Q.; Liu, H. Y.; Sun, H. Y.; Liu, L. H.; Han, R. S.

    2016-04-01

    Cu2O nanoporous films are deposited on porous anodic alumina (PAA) substrates by DC-reactive magnetron sputtering. This paper focuses on voltage driven magnetization switching in Cu2O/PAA (CP) composite films prepared by DC-reactive magnetron sputtering. By applying a dc electric field, the magnetization of the CP composite films can be controlled in a reversible and reproducible way and shows an analogous on-off behavior. The magnitude of the change in the magnetization was about 75 emu/cm3 as the electric field was switched on and off. Resistive switching behavior was also observed in as-prepared CP composite films. Further analysis indicated that the formation/rupture of conducting filaments composed of oxygen vacancies is likely responsible for the changes in the magnetization as well as in the resistivity. Such reversible change of magnetization controlled by an electric field at room temperature may have applications in spintronics and power efficient data storage technologies.

  12. Sound field control in a rectangular room at low frequencies to simulate the sound radiated by a virtual source

    DEFF Research Database (Denmark)

    Orozco, Arturo; Uchiyama, Michiaki; Tohyama, Mikio

    1999-01-01

    The sound reproduced in a room by a conventional audio system is modified because of the acoustic response of the room. In this paper a theoreticalstudy based on computer simulations for the synthesis of a desired sound field in a room is presented. The optimal solution in a continuous region...... that covers almost the entire volume of the room has been obtained with the least-square approximation. It is shown that the synthesis of travelling waves in a certain direction is possible at frequencies up to 320 Hz in a room with dimensions 2.9x3.6x2.5 m using 32 loudspeakers. If waves travelling in any...

  13. The public health sector supply of modern contraceptives in rural Nigeria: an analysis of selection, forecasting and inventory control

    Directory of Open Access Journals (Sweden)

    Asa Auta

    2011-07-01

    Full Text Available Public health facilities in rural Nigeria have been experiencing a long period of stock-outs and unavailability of modern contraceptives. This work was carried out to review the public health sector supply of modern contraceptives in rural Nigeria in order to make recommendations on how to improve the supply of modern contraceptives in this area. The study reviewed secondary data from country documents and literature obtained from Pubmed, Popline, and Global Health databases; as well as websites of USAID/DELIVER Project, Measure DHS and Federal Ministry of Health. The study revealed that a wide range of contraceptives are included in the essential drug list to be used in secondary facilities, while only a few ones are selected to be used in primary facilities which serve the majority of rural population. Forecasting is done using issue data from the central warehouse because facilities are not generating reliable consumption data. Inventory control is poor in rural facilities, and these facilities do not follow the established inventory control guidelines. The study therefore demonstrates that the current essential drug list should be reviewed in order to include injectables for use in primary facilities, strengthen the current forecasting, data reporting and inventory control system.

  14. Experiences in the application of human factors engineering to human-system interface modernization

    Energy Technology Data Exchange (ETDEWEB)

    Trueba Alonso, Pedro; Fernandez Illobre, Luis; Ortega Pascual, Fernando [Tecnatom S.A., San Sebastian de los Reyes (Spain). Simulation and Control Rooms Div.

    2015-07-15

    Almost all the existing Nuclear Power Plants (NPPs) include plans to modernize their existing Instrumentation and Control (I and C) systems and associated Human System Interfaces (HSIs), due to obsolescence problems. Tecnatom, S.A. has been participating in modernization programs in NPPs to help them to plan, specify, design and implement the modernization of control rooms and associated I and C and HSIs. The application of Human Factors Engineering (HFE) in modernization programs is nowadays unavoidable. This is because is becoming a regulatory requirement, and also because it is needed to ensure that any plant modification, involving the modernization of I and C and HSI, is well designed to improve overall plant operations, reliability, and safety. This paper shows some experiences obtained during the application of HFE to the modernization of these HSIs. The experience applying HFE in modernizations and design modifications show a positive effect, improving the associated HSIs, with the acceptability of the final user.

  15. Controllable Growth of Perovskite Films by Room-Temperature Air Exposure for Efficient Planar Heterojunction Photovoltaic Cells.

    Science.gov (United States)

    Yang, Bin; Dyck, Ondrej; Poplawsky, Jonathan; Keum, Jong; Das, Sanjib; Puretzky, Alexander; Aytug, Tolga; Joshi, Pooran C; Rouleau, Christopher M; Duscher, Gerd; Geohegan, David B; Xiao, Kai

    2015-12-01

    A two-step solution processing approach has been established to grow void-free perovskite films for low-cost high-performance planar heterojunction photovoltaic devices. A high-temperature thermal annealing treatment was applied to drive the diffusion of CH3NH3I precursor molecules into a compact PbI2 layer to form perovskite films. However, thermal annealing for extended periods led to degraded device performance owing to the defects generated by decomposition of perovskite into PbI2. A controllable layer-by-layer spin-coating method was used to grow "bilayer" CH3NH3I/PbI2 films, and then drive the interdiffusion between PbI2 and CH3NH3I layers by a simple air exposure at room temperature for making well-oriented, highly crystalline perovskite films without thermal annealing. This high degree of crystallinity resulted in a carrier diffusion length of ca. 800 nm and a high device efficiency of 15.6%, which is comparable to values reported for thermally annealed perovskite films.

  16. Study on Intellective Fuzzy Control System for Oil Pump Room%军队油库泵房智能控制仿真系统研究

    Institute of Scientific and Technical Information of China (English)

    周庆忠; 何涪

    2011-01-01

    对军队油库泵房收发油故障进行综合分析,论述军队油库泵房智能控制仿真系统的工作原理,设计了位置模糊控制器及其软件,提出了泵房设备模糊控制的设计方法,给出了仿真系统的应用实例,对实现军队油库泵房各种设备的智能模糊控制,具有科学性和实用性.%In this paper, the accident of oil receiving and deporting in oil pump room are analyzed. The working principles of intellective fuzzy control system for oil pump room are discussed. The design ways of location fuzzy controller, its software and mechanical fuzzy control for pump room are described. The authors expound that the application of this system realizes intellective fuzzy control to a varieties of mechanism in oil pump room, and this system is scientific and practical.

  17. Piloted Evaluation of Modernized Limited Authority Control Laws in the NASA-Ames Vertical Motion Simulator (VMS)

    Science.gov (United States)

    Sahasrabudhe, Vineet; Melkers, Edgar; Faynberg, Alexander; Blanken, Chris L.

    2003-01-01

    The UH-60 BLACK HAWK was designed in the 1970s, when the US Army primarily operated during the day in good visual conditions. Subsequently, the introduction of night-vision goggles increased the BLACK HAWK'S mission effectiveness, but the accident rate also increased. The increased accident rate is strongly tied to increased pilot workload as a result of a degradation in visual cues. Over twenty years of research in helicopter flight control and handling qualities has shown that these degraded handling qualities can be recovered by modifying the response type of the helicopter in low speed flight. Sikorsky Aircraft Corporation initiated a project under the National Rotorcraft Technology Center (NRTC) to develop modern flight control laws while utilizing the existing partial authority Stability Augmentation System (SAS) of the BLACK HAWK. This effort resulted in a set of Modernized Control Laws (MCLAWS) that incorporate rate command and attitude command response types. Sikorsky and the US Army Aeroflightdynamics Directorate (AFDD) conducted a piloted simulation on the NASA-Ames Vertical h4otion Simulator, to assess potential handling qualities and to reduce the risk of subsequent implementation and flight test of these modern control laws on AFDD's EH-60L helicopter. The simulation showed that Attitude Command Attitude Hold control laws in pitch and roll improve handling qualities in the low speed flight regime. These improvements are consistent across a range of mission task elements and for both good and degraded visual environments. The MCLAWS perform better than the baseline UH-60A control laws in the presence of wind and turbulence. Finally, while the improved handling qualities in the pitch and roll axis allow the pilot to pay more attention to the vertical axis and hence altitude performance also improves, it is clear from pilot comments and altitude excursions that the addition of an Altitude Hold function would further reduce workload and improve overall

  18. Taking control of your digital library: how modern citation managers do more than just referencing.

    Science.gov (United States)

    Mahajan, Amit K; Hogarth, D Kyle

    2013-12-01

    Physicians are constantly navigating the overwhelming body of medical literature available on the Internet. Although early citation managers were capable of limited searching of index databases and tedious bibliography production, modern versions of citation managers such as EndNote, Zotero, and Mendeley are powerful web-based tools for searching, organizing, and sharing medical literature. Effortless point-and-click functions provide physicians with the ability to develop robust digital libraries filled with literature relevant to their fields of interest. In addition to easily creating manuscript bibliographies, various citation managers allow physicians to readily access medical literature, share references for teaching purposes, collaborate with colleagues, and even participate in social networking. If physicians are willing to invest the time to familiarize themselves with modern citation managers, they will reap great benefits in the future.

  19. Evaluation of Modern Navies’ Damage Control and Firefighting Training using Simulator Platforms

    Science.gov (United States)

    2011-09-01

    15 2. USS Forrestal ( CVA -59) Incident.....................................................17 3...2. USS Forrestal ( CVA -59) Incident The following information is based on the Master Thesis of Henry P. Stewart, USN, 2004. On July 29, 1967, one...of the most severe catastrophes in recent naval history happened aboard the USS Forrestal ( CVA 59), one of the U.S Navy’s most modern aircraft

  20. THE APPLICATION OF COMPOSITE MATERIALS IN MODERN AVIATION AND CONTROL OF ITS CONDITION DURING DESIGN SERVICE GOAL

    Directory of Open Access Journals (Sweden)

    A. V. Zibitsky

    2014-01-01

    Full Text Available This article has a purpose to give a brief review of usage of composite materials in the structure of modern civil aircraft. The current condition of civil aviation was analyzed, serious problems were determined and possible achievements in the future were discussed. Advantages and disadvantages of composite materials were analyzed, non-destructive methods of control were reviewed and the necessity to design new method, which allows to control the integrity of structure in real time during design service goal of the aircraft (the concept of “clever material” was shown.

  1. Modernization project of the rod control system and in-core instrumentation system for 34 units of the 900 MW French EDF fleet

    Energy Technology Data Exchange (ETDEWEB)

    Tavolara, Ivan [Rolls-Royce, Civil Nuclear Business, Instrumentation and Controls, 23, Chemin du Vieux Chene 38246 Meylan-Cedex (France); Verburgh, Pierre [Cegelec SA, Energy Control and Systems, Rue Santos Dumont 3, 6041 Gosselies (Belgium); Menager, Antoine [EDF Engineering Department for Nuclear Plants In Operation (CIPN), 140, avenue Viton, 13401 Marseille Cedex 20 (France)

    2010-07-01

    Rolls-Royce and Cegelec, in partnership, carry out a unique and considerable modernisation project of two Instrumentation and Control (I and C) systems for the entire 900 MWe fleet of Electricite De France (EDF). Both rod control (RCS) and reactor in-core measurement (RIC) systems are to be modernised in the frame of the third ten-year renovation of all 34 reactor units over 9 power plants. The RCS contributes to the control of nuclear power by actuating control rod drive mechanisms that allow insertion or withdrawal of control rods. The RCS has also monitoring functions such as controlling the actual rods' position as well as the functional consistency between commands and actual positions. The RIC system measures in-core neutron flux, providing useful information to the control room as well as to the reactor unit computer for further processing. The renovated systems shall replace the existing ageing analog technology by modern digital technology based on PLC (Programmable Logic Controllers) and FPGA (Field-Programmable Gate Array) in the case of power subassemblies of RCS. Both systems rely for certain functions on a common network linking the RCS and RIC networks, improving operations and maintenance thanks to a powerful Man Machine Interface at the different locations of the systems with an extensive suite of tools and diagnostic menus. The project whose design phase started in July 2006 is now in its deployment phase after the successful site implementation of both systems at the first units of Tricastin and Fessenheim power plants, respectively in August 2009 and February 2010. The deployment shall continue with the other 32 units until 2020. Rolls-Royce has a broad range of civil nuclear expertise, including work related to licensing and safety reviews, engineering design, supply chain management, manufacturing, installation and commissioning of the nuclear island systems and equipment, as well as operational management through life support. Cegelec

  2. Leap Motion Gesture Control With Carestream Software in the Operating Room to Control Imaging: Installation Guide and Discussion.

    Science.gov (United States)

    Pauchot, Julien; Di Tommaso, Laetitia; Lounis, Ahmed; Benassarou, Mourad; Mathieu, Pierre; Bernot, Dominique; Aubry, Sébastien

    2015-12-01

    Nowadays, routine cross-sectional imaging viewing during a surgical procedure requires physical contact with an interface (mouse or touch-sensitive screen). Such contact risks exposure to aseptic conditions and causes loss of time. Devices such as the recently introduced Leap Motion (Leap Motion Society, San Francisco, CA), which enables interaction with the computer without any physical contact, are of wide interest in the field of surgery, but configuration and ergonomics are key challenges for the practitioner, imaging software, and surgical environment. This article aims to suggest an easy configuration of Leap Motion on a PC for optimized use with Carestream Vue PACS v11.3.4 (Carestream Health, Inc, Rochester, NY) using a plug-in (to download at https://drive.google.com/open?id=0B_F4eBeBQc3yNENvTXlnY09qS00&authuser=0) and a video tutorial (https://www.youtube.com/watch?v=yVPTgxg-SIk). Videos of surgical procedure and discussion about innovative gesture control technology and its various configurations are provided in this article.

  3. An Investigation for Arranging the Video Display Unit Information in a Main Control Room of Advanced Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Hsu, Chong Cheng; Yang, Chih Wei [Institute of Nuclear Energy Research, Atomic Energy Council, Taoyuan (China)

    2014-08-15

    Current digital instrumentation and control and main control room (MCR) technology has extended the capability of integrating information from numerous plant systems and transmitting needed information to operations personnel in a timely manner that could not be envisioned when previous generation plants were designed and built. A MCR operator can complete all necessary operating actions on the video display unit (VDU). It is extremely flexible and convenient for operators to select and to control the system display on the screen. However, a high degree of digitalization has some risks. For example, in nuclear power plants, failures in the instrumentation and control devices could stop the operation of the plant. Human factors engineering (HFE) approaches would be a manner to solve this problem. Under HFE considerations, there exists 'population stereotype' for operation. That is, the operator is used to operating a specific display on the specific VDU for operation. Under emergency conditions, there is possibility that the operator will response with this habit population stereotype, and not be aware that the current situation has already changed. Accordingly, the advanced nuclear power plant should establish the MCR VDU configuration plan to meet the consistent teamwork goal under normal operation, transient and accident conditions. On the other hand, the advanced nuclear power plant should establish the human factors verification and validation plan of the MCR VDU configuration to verify and validate the configuration of the MCR VDUs, and to ensure that the MCR VDU configuration allows the operator shift to meet the HFE consideration and the consistent teamwork goal under normal operation, transient and accident conditions. This paper is one of the HF V V plans of the MCR VDU configuration of the advanced nuclear power plant. The purpose of this study is to confirm whether the VDU configuration meets the human factors principles and the consistent

  4. Association between birth order and emergency room visits and acute hospital admissions following pediatric vaccination: a self-controlled study.

    Directory of Open Access Journals (Sweden)

    Steven Hawken

    Full Text Available OBJECTIVE: We investigated the association between a child's birth order and emergency room (ER visits and hospital admissions following 2-,4-,6- and 12-month pediatric vaccinations. METHODS: We included all children born in Ontario between April 1(st, 2006 and March 31(st, 2009 who received a qualifying vaccination. We identified vaccinations, ER visits and admissions using health administrative data housed at the Institute for Clinical Evaluative Sciences. We used the self-controlled case series design to compare the relative incidence (RI of events among 1(st-born and later-born children using relative incidence ratios (RIR. RESULTS: For the 2-month vaccination, the RIR for 1(st-borns versus later-born children was 1.37 (95% CI: 1.19-1.57, which translates to 112 additional events/100,000 vaccinated. For the 4-month vaccination, the RIR for 1(st-borns vs. later-borns was 1.70 (95% CI: 1.45-1.99, representing 157 additional events/100,000 vaccinated. At 6 months, the RIR for 1(st vs. later-borns was 1.27 (95% CI: 1.09-1.48, or 77 excess events/100,000 vaccinated. At the 12-month vaccination, the RIR was 1.11 (95% CI: 1.02-1.21, or 249 excess events/100,000 vaccinated. CONCLUSIONS: Birth order is associated with increased incidence of ER visits and hospitalizations following vaccination in infancy. 1(st-born children had significantly higher relative incidence of events compared to later-born children.

  5. Thermochronology of the modern Indus River bedload: New insight into the controls on the marine stratigraphic record

    Science.gov (United States)

    Clift, Peter D.; Campbell, Ian H.; Pringle, Malcolm S.; Carter, Andrew; Zhang, Xifan; Hodges, Kip V.; Khan, Ali Athar; Allen, Charlotte M.

    2004-10-01

    The Indus River is the only major drainage in the western Himalaya and delivers a long geological record of continental erosion to the Arabian Sea, which may be deciphered and used to reconstruct orogenic growth if the modern bedload can be related to the mountains. In this study we collected thermochronologic data from river sediment collected near the modern delta. U-Pb ages of zircons spanning 3 Gyr show that only ˜5% of the eroding crust has been generated since India-Asia collision. The Greater Himalaya are the major source of zircons, with additional contributions from the Karakoram and Lesser Himalaya. The 39Ar/40Ar dating of muscovites gives ages that cluster between 10 and 25 Ma, differing from those recorded in the Bengal Fan. Biotite ages are generally younger, ranging 0-15 Ma. Modern average exhumation rates are estimated at ˜0.6 km/m.y. or less, and have slowed progressively since the early Miocene (˜20 Ma), although fission track (FT) dating of apatites may indicate a recent moderate acceleration in rates since the Pliocene (˜1.0 km/m.y.) driven by climate change. The 39Ar/40Ar and FT techniques emphasize the dominance of high topography in controlling the erosional flux to the ocean. Localized regions of tectonically driven, very rapid exhumation (e.g., Nanga Parbat, S. Karakoram metamorphic domes) do not dominate the erosional record.

  6. Modernity after Modernity

    Directory of Open Access Journals (Sweden)

    Marin Dinu

    2007-08-01

    Full Text Available A strategy for the second modernization raises, beyond objectives, a series of epistemicresponsibilities. It is known that modernization stemming from the Enlightment had, among other things,the pretense that it is a project which is self-legitimating. Its profound rationales are the only justification.Referential self-centering proved to be the one that made possible a practice of the new. Modernizationhaving the function of renouncing myth – meaning an eliminatory formula for the past – and thefixation in the opportunity and potentiality of the present, seemed to close an insoluble but extremelyengrossing problem: that of a propensity towards utopia, of the risky escape towards the future. Thetraditionalization of the new constitutes a support for the daring to break out of the captivity of themoment.Modernization becomes the experience of combining the new which, thus, creates a succession ofpresent times. The future is no longer the result of fantasy, but a system’s direct expression to combine thenew. Therefore the future is an option for one or another model of the present, often tested previouslysomewhere else. In a non-metaphysical way, the future can be seen, touched, tried, lived by simplegeographical movement. The sense of evolution has de-temporalized taking the form of the concomitant,parallel, enclosed, neighboring space. We just have to be in the trend, to evolve in the context.Globalization defines the context and its conception – as a project of the second modernity – showsus the trends. The problem is how to understand the context in order to find the sense of the trend. Are wethe load the sense with the values of the first modernity or will we have to turn to the values of anothermodernity? Why do we have to move away from the significance of the processes which made up the firstmodernity? How do we relate to the content of the new context in which the structural trends of today’sworld are taking place? What is the

  7. The effects of emission control strategies on light-absorbing carbon emissions from a modern heavy-duty diesel engine.

    Science.gov (United States)

    Robinson, Michael A; Olson, Michael R; Liu, Z Gerald; Schauer, James J

    2015-06-01

    Control of atmospheric black carbon (BC) and brown carbon (BrC) has been proposed as an important pathway to climate change mitigation, but sources of BC and BrC are still not well understood. In order to better identify the role of modern heavy-duty diesel engines on the production of BC and BrC, emissions from a heavy-duty diesel engine operating with different emission control strategies were examined using a source dilution sampling system. The effect of a diesel oxidation catalyst (DOC) and diesel particulate filter (DPF) on light-absorbing carbon (LAC) was evaluated at three steady-state engine operation modes: idle, 50% speed and load, and 100% speed and load. LAC was measured with four different engine configurations: engine out, DOC out, DPF out, and engine out with an altered combustion calibration. BC and BrC emission rates were measured with the Aethalometer (AE-31). EC and BC emission rates normalized to the mass of CO₂emitted increased with increasing engine speed and load. Emission rates normalized to brake-specific work did not exhibit similar trends with speed and load, but rather the highest emission rate was measured at idle. EC and OC emissions were reduced by 99% when the DOC and DPF architecture was applied. The application of a DPF was equally effective at removing 99% of the BC fraction of PM, proving to be an important control strategy for both LAC and PM. BC emissions were unexpectedly increased across the DOC, seemingly due to a change aerosol optical properties. Removal of exhaust gas recirculation (EGR) flow due to simulated EGR cooler failure caused a large increase in OC and BrC emission rates at idle, but had limited influence during high load operation. LAC emissions proved to be sensitive to the same control strategies effective at controlling the total mass of diesel PM. In the context of black carbon emissions, very small emission rates of brown carbon were measured over a range of control technologies and engine operating

  8. A modern neuroscience approach to chronic spinal pain: combining pain neuroscience education with cognition-targeted motor control training.

    Science.gov (United States)

    Nijs, Jo; Meeus, Mira; Cagnie, Barbara; Roussel, Nathalie A; Dolphens, Mieke; Van Oosterwijck, Jessica; Danneels, Lieven

    2014-05-01

    Chronic spinal pain (CSP) is a severely disabling disorder, including nontraumatic chronic low back and neck pain, failed back surgery, and chronic whiplash-associated disorders. Much of the current therapy is focused on input mechanisms (treating peripheral elements such as muscles and joints) and output mechanisms (addressing motor control), while there is less attention to processing (central) mechanisms. In addition to the compelling evidence for impaired motor control of spinal muscles in patients with CSP, there is increasing evidence that central mechanisms (ie, hyperexcitability of the central nervous system and brain abnormalities) play a role in CSP. Hence, treatments for CSP should address not only peripheral dysfunctions but also the brain. Therefore, a modern neuroscience approach, comprising therapeutic pain neuroscience education followed by cognition-targeted motor control training, is proposed. This perspective article explains why and how such an approach to CSP can be applied in physical therapist practice.

  9. Modification and updating of documentation in equipment of panels of control room in nuclear power plant operation; Modificacion y actualizacion de documentacion en aparatos de paneles de sala de control en una central nuclear en operacion

    Energy Technology Data Exchange (ETDEWEB)

    Agudo Montero, L.

    2013-07-01

    The present paper describes a case very unique specific design of interactive 2D-CAD application, that has been developed by Empresarios Agrupados as engineering support to the nuclear power plants, aware of the problem that exists with the documentation of the instruments and devices that are on the panels of Control room, and that only have the documentation generated in its day by the manufacturers of these panels. To this end, an application (application DOPAB) has been developed to help solve the problem of management, design and modification of wiring and wiring devices existing in the Control room control panels.

  10. Difficult points and countermeasures for hospital infection control in operating room%手术室医院感染控制的难点及对策

    Institute of Scientific and Technical Information of China (English)

    冯迎辉

    2011-01-01

    Objective:To solve the difficulties of controlling hospital infection in operating room and give some solutions to this problem in order to improve the quality of nursing. Methods: The problems which found in our hospital in daily work were analyzed, improved and summaried, such as the operating room environment, the management of sterile goods, hand hygiene, movement in the surgery. Results: Cut the way caused the operating room infection, make the indicators of the operating room in the normal range, could avoid the occurrence of various surgical infections and improve the quality of health care. Conclusion: The effective implementations of the operating room disinfection and isolation measures were an important way to control hospital infection.%目的:解决手术室医院感染控制的难点并探讨手术室医院感染控制对策,以提高医疗护理质量.方法:通过我院感染管理科在日常工作中发现的问题,如手术室环境、无菌物品的管理、手卫生、手术中人员流动、各项感染措施及各项制度的落实等找出原因进行分析、整改和总结.结果:切断了引起手术室医院感染的途径,使手术室的各项指标在正常范围,避免了各项手术感染的发生,提高了医院的医疗护理质量.结论:有效地落实手术室消毒隔离措施是控制医院感染的重要途径.

  11. Size-controllable APTS stabilized ruthenium(0) nanoparticles catalyst for the dehydrogenation of dimethylamine-borane at room temperature.

    Science.gov (United States)

    Zahmakıran, Mehmet; Philippot, Karine; Özkar, Saim; Chaudret, Bruno

    2012-01-14

    Dimethylamine-borane, (CH(3))(2)NHBH(3), has been considered as one of the attractive materials for the efficient storage of hydrogen, which is still one of the key issues in the "Hydrogen Economy". In a recent communication we have reported the synthesis and characterization of 3-aminopropyltriethoxysilane stabilized ruthenium(0) nanoparticles with the preliminary results for their catalytic performance in the dehydrogenation of dimethylamine-borane at room temperature. Herein, we report a complete work including (i) effect of initial [APTS]/[Ru] molar ratio on both the size and the catalytic activity of ruthenium(0) nanoparticles, (ii) collection of extensive kinetic data under non-MTL conditions depending on the substrate and catalyst concentrations to define the rate law of Ru(0)/APTS-catalyzed dehydrogenation of dimethylamine-borane at room temperature, (iii) determination of activation parameters (E(a), ΔH(#) and ΔS(#)) for Ru(0)/APTS-catalyzed dehydrogenation of dimethylamine-borane; (iv) demonstration of the catalytic lifetime of Ru(0)/APTS nanoparticles in the dehydrogenation of dimethylamine-borane at room temperature, (v) testing the bottlability and reusability of Ru(0)/APTS nanocatalyst in the room-temperature dehydrogenation of dimethylamine-borane, (vi) quantitative carbon disulfide (CS(2)) poisoning experiments to find a corrected TTO and TOF values on a per-active-ruthenium-atom basis, (vii) a summary of extensive literature review for the catalysts tested in the catalytic dehydrogenation of dimethylamine-borane as part of the results and discussions.

  12. Development of human performance evaluation methods and systems for human factors validation in an advanced control room

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Jun Su

    2008-02-15

    Advanced control room (ACR) human-machine interface (HMI) design of advanced nuclear power plants (NPPs) such as APR (advanced power reactor)-1400 can be validated through performance-based tests to determine whether it acceptably supports safe operation of the plant. In this paper, plant performance, personnel task performance, situation awareness, workload, teamwork, and anthropometric/ physiological factor are considered as factors for the human performance evaluation. For development of measures in each of the factors, measures generally used in various industries and empirically proven to be useful are adopted as main measures with some modifications. In addition, helpful measures are developed as complementary measures in order to overcome some of the limitations associated with the main measures. The development of the measures is addressed based on the theoretical and empirical background and also based on the regulatory guidelines. A computerized system, which is called HUPESS (human performance evaluation support system), is developed based on the measures developed in this paper. The development of HUPESS is described with respect to the system configuration, the development process, and integrated measurement, evaluation, and analysis. HUPESS supports evaluators (or experimenters) to effectively measure, analyze, and evaluate the human performance for the HMI design validation in ACRs. Hence HUPESS is expected to be used as an effective tool for the human factors validation in the ACR of Shin Kori 3 and 4 NPPs (APR-1400 type) which are under construction in South-Korea. Also two measures of attentional-resource effectiveness based on cost-benefit analysis are developed. One of them is Fixation to Importance Ratio (FIR) which represents the attentional resources spent on an information source compared to the importance of the information source. The other measure is selective attention effectiveness (SAE) which incorporates the FIRs for all information

  13. Flight test results for the Digital Integrated Automatic Landing Systems (DIALS): A modern control full-state feedback design

    Science.gov (United States)

    Hueschen, R. M.

    1984-01-01

    The Digital Integrated Automatic Landing System (DIALS) is discussed. The DIALS is a modern control theory design performing all the maneuver modes associated with current autoland systems: localizer capture and track, glideslope capture and track, decrab, and flare. The DIALS is an integrated full-state feedback system which was designed using direct-digital methods. The DIALS uses standard aircraft sensors and the digital Microwave Landing System (MLS) signals as measurements. It consists of separately designed longitudinal and lateral channels although some cross-coupling variables are fed between channels for improved state estimates and trajectory commands. The DIALS was implemented within the 16-bit fixed-point flight computers of the ATOPS research aircraft, a small twin jet commercial transport outfitted with a second research cockpit and a fly-by-wire system. The DIALS became the first modern control theory design to be successfully flight tested on a commercial-type aircraft. Flight tests were conducted in late 1981 using a wide coverage MLS on Runway 22 at Wallops Flight Center. All the modes were exercised including the capture and track of steep glidescopes up to 5 degrees.

  14. Human factors issues and approaches in the spatial layout of a space station control room, including the use of virtual reality as a design analysis tool

    Science.gov (United States)

    Hale, Joseph P., II

    1994-01-01

    Human Factors Engineering support was provided for the 30% design review of the late Space Station Freedom Payload Control Area (PCA). The PCA was to be the payload operations control room, analogous to the Spacelab Payload Operations Control Center (POCC). This effort began with a systematic collection and refinement of the relevant requirements driving the spatial layout of the consoles and PCA. This information was used as input for specialized human factors analytical tools and techniques in the design and design analysis activities. Design concepts and configuration options were developed and reviewed using sketches, 2-D Computer-Aided Design (CAD) drawings, and immersive Virtual Reality (VR) mockups.

  15. Modern recording techniques

    CERN Document Server

    Huber, David Miles

    2013-01-01

    As the most popular and authoritative guide to recording Modern Recording Techniques provides everything you need to master the tools and day to day practice of music recording and production. From room acoustics and running a session to mic placement and designing a studio Modern Recording Techniques will give you a really good grounding in the theory and industry practice. Expanded to include the latest digital audio technology the 7th edition now includes sections on podcasting, new surround sound formats and HD and audio.If you are just starting out or looking for a step up

  16. Challenges for maintaining the modernization of instrumentation and control systems; Desafios para el mantenimiento en la modernizacion de sistemas de instrumentacion y control

    Energy Technology Data Exchange (ETDEWEB)

    Rojas, V.

    2014-04-01

    Instrumentation and control system upgrades in nuclear power plants come with some challenges for their maintenance staff. It is important to have a long term modernization plant that derives from specific studies for each system. Training, spares, configuration control and cybersecurity are critical topics to take into account from the beginning of these projects. New system maintenance plans can require a new approach in accordance with the technology. FPGAs (Field Programmable Gate Array) appear as the alternative for the future, mainly in safety systems. (Author)

  17. Design and implementation of modern control algorithms for unmanned aerial vehicles

    Science.gov (United States)

    Hafez, Ahmed Taimour

    Recently, Unmanned Aerial Vehicles (UAVs) have attracted a great deal of attention in academic, civilian and military communities as prospective solutions to a wide variety of applications. The use of cooperative UAVs has received growing interest in the last decade and this provides an opportunity for new operational paradigms. As applications of UAVs continue to grow in complexity, the trend of using multiple cooperative UAVs to perform these applications rises in order to increase the overall effectiveness and robustness. There is a need for generating suitable control techniques that allow for the real-time implementation of control algorithms for different missions and tactics executed by a group of cooperative UAVs. In this thesis, we investigate possible control patterns and associated algorithms for controlling a group of autonomous UAVs in real-time to perform various tactics. This research proposes new control approaches to solve the dynamic encirclement, tactic switching and formation problems for a group of cooperative UAVs in simulation and real-time. Firstly, a combination of Feedback Linearization (FL) and decentralized Linear Model Predictive Control (LMPC) is used to solve the dynamic encirclement problem. Secondly, a combination of decentralized LMPC and fuzzy logic control is used to solve the problem of tactic switching for a group of cooperative UAVs. Finally, a decentralized Learning Based Model Predictive Control (LBMPC) is used to solve the problem of formation for a group of cooperative UAVs in simulation. We show through simulations and validate through experiments that the proposed control policies succeed to control a group of cooperative UAVs to achieve the desired requirements and control objectives for different tactics. These proposed control policies provide reliable and effective control techniques for multiple cooperative UAV systems.

  18. 现代医院质量管理思想研究%Research on Modern Hospital Quality Control Thought

    Institute of Scientific and Technical Information of China (English)

    任真年

    2000-01-01

    为探讨现代医院质量管理思想,借鉴企业和商业质量管理经验,结合我国、我军医院实际情况,提出了:全面质量经营;质量教育;质量信息;质量保证;质量文化;质量改进;质量零缺点;质量80/20原理;顾客满意;质量创新;质量效益。%Do inquire into modern hospital quality control thought, use for reference enterprise and commerce quality control taste ,lambda binding our country, our army hospital truth ,put forward: total quality management ; quality education ; quality information ; quality assurance ; quality culture ; quality brushup ;quality null defect ; quality 80/20 principle ; customer satisfied; quality benefit.

  19. The editor dilemma in modern language instruction: Is tutoring out of control?

    Directory of Open Access Journals (Sweden)

    Maite Correa

    2014-01-01

    Full Text Available Although academic dishonesty has received considerable attention in recent years, there is little research on how non-serious cheating issues in a discipline such as biology or chemistry can become highly serious offenses in the context of instruction in the modern languages (MLs. One of these grey areas is (unauthorized editing by a tutor and/or a native speaker: Given that a substantial part (if not all of the grade in a ML assignment is language usage (be it grammar, vocabulary, spelling, or organization, any assistance received that improves linguistic form (and as a consequence the student’s grade should be considered as an act of punishable academic dishonesty. Still, and even if it seems obvious, it is not uncommon for language instructors to come across assignments that contain advanced linguistic forms or colloquialisms that do not belong to the linguistic repertoire of the student who wrote it (Correa, 2011. In this paper I address the following questions: Is the use of a tutor/native speaker accidental plagiarism (Beasley, 2004, pseudepigraphy (Walker & Townley, 2012, or contract cheating (Clarke & Lancaster, 2006? Who is at fault? How can it be prevented or minimized? Should students be allowed to have tutors at all? Is there a double standard when it comes to graduate students and faculty?

  20. ANALYSIS OF THE HUMAN FACTOR AT CONTROL OF THE MODERN AIRCRAFT

    Directory of Open Access Journals (Sweden)

    С.В. Павлова

    2012-12-01

    Full Text Available  Functional interaction features of the operator with a difficult control system have been considered at airplane control. Necessity of working out of vector model of the operator as integral part of difficult system has been revealed.

  1. Modern Control Strategies of Doubly-Fed Induction Generator Based Wind Turbine System

    DEFF Research Database (Denmark)

    Zhou, Dao; Song, Yipeng; Blaabjerg, Frede

    2017-01-01

    -through operation, as well as steady and safe operation during long-term distorted grid), control strategies are continuously evolving. This paper starts with a control strategy using the combined reactive power compensation from both the back-to-back power converters for their optimized lifetime distribution under...

  2. An application of modern control theory to jet propulsion systems. [considering onboard computer

    Science.gov (United States)

    Merrill, W. C.

    1975-01-01

    The control of an airbreathing turbojet engine by an onboard digital computer is studied. The approach taken is to model the turbojet engine as a linear, multivariable system whose parameters vary with engine operating environment. From this model adaptive closed-loop or feedback control laws are designed and applied to the acceleration of the turbojet engine.

  3. Average Air Temperature Inside a Room With a Semitransparent Wall With a Solar Control Film: Effect of The Emissivity

    OpenAIRE

    J. Xamán; Álvarez, G; Chávez, Y.; J. O. Aguilar; Arce, J.

    2012-01-01

    In this paper a theoretical study on conjugated heat transfer (natural convection, radiation and conduction) in a squareroom (cavity) with turbulent flow is presented, taking into account variation on the opaque wall emissivity. The room isformed by an isothermal vertical wall, two adiabatic horizontal walls and a semitransparent wall with and without acontrol solar radiation film. The governing equations for turbulent flow in 2D were solved using a finite volumeformulation and k- turbulent ...

  4. Modern Control Strategies for Double-Fed Induction Generator Based Wind Turbine System

    DEFF Research Database (Denmark)

    Zhou, Dao; Song, Yipeng; Blaabjerg, Frede

    2016-01-01

    A doubly-fed induction generator (DFIG) based configuration is still preferred by wind turbine manufactures due to the cost-effective power converter and independent control of the active power and reactive power. To cope with stricter grid codes (e.g. reactive power compensation, low voltage ride......, with the control targets of the smooth active and reactive power or the balances and sinusoidal current of the rotor-side converter and the grid-side converter. Finally, a bandwidth based repetitive controller is evaluated to improve the DFIG system's robustness against grid frequency deviation....... normal grid conditions. Afterwards, an advanced demagnetizing control is proposed to keep the minimum thermal stress of the rotor-side converter in the case of the short-term grid fault. A modularized control strategy of the DFIG system under unbalanced and distorted grid voltage is discussed...

  5. Application of modern control design methodology to oblique wing research aircraft

    Science.gov (United States)

    Vincent, James H.

    1991-01-01

    A Linear Quadratic Regulator synthesis technique was used to design an explicit model following control system for the Oblique Wing Research Aircraft (OWRA). The forward path model (Maneuver Command Generator) was designed to incorporate the desired flying qualities and response decoupling. The LQR synthesis was based on the use of generalized controls, and it was structured to provide a proportional/integral error regulator with feedforward compensation. An unexpected consequence of this design approach was the ability to decouple the control synthesis into separate longitudinal and lateral directional designs. Longitudinal and lateral directional control laws were generated for each of the nine design flight conditions, and gain scheduling requirements were addressed. A fully coupled 6 degree of freedom open loop model of the OWRA along with the longitudinal and lateral directional control laws was used to assess the closed loop performance of the design. Evaluations were performed for each of the nine design flight conditions.

  6. Average Air Temperature Inside a Room With a Semitransparent Wall With a Solar Control Film: Effect of The Emissivity

    Directory of Open Access Journals (Sweden)

    J. Xamán

    2012-06-01

    Full Text Available In this paper a theoretical study on conjugated heat transfer (natural convection, radiation and conduction in a squareroom (cavity with turbulent flow is presented, taking into account variation on the opaque wall emissivity. The room isformed by an isothermal vertical wall, two adiabatic horizontal walls and a semitransparent wall with and without acontrol solar radiation film. The governing equations for turbulent flow in 2D were solved using a finite volumeformulation and k- turbulent model. Results for an isothermal wall at 21°C and an external temperature of 35°C arepresented. The size of the room is 4.0 m length and height and the solar radiation falling directly on thesemitransparent wall was 750 W/m2 (AM2. The emissivity of the opaque walls was varied between 0.1 ≤ * ≤ 1.0.Results show that, based on the air average temperature and the effective heat flux inside the room, the solar controlfilm under study was advantageous for energy saving purposes, for emissivity values of * ≤ 0.46. A correlation onthis system for the heat transfer as a function of the emissivities was determined.

  7. Controls on modern tributary-junction alluvial fan occurrence and morphology: High Atlas Mountains, Morocco

    Science.gov (United States)

    Stokes, Martin; Mather, Anne E.

    2015-11-01

    Modern tributary-junction alluvial fans (cone-shaped depositional landforms formed in confined valley settings) were analysed from a 20-km-long reach of the Dades River in the distal part of the fold-thrust belt region in the south-central High Atlas Mountains of Morocco. Here, a deeply dissected network of ephemeral tributary streams and a perennial trunk drainage characterised by an arid mountain desert climate are configured onto a folded and thrust faulted Mesozoic sedimentary sequence. Out of 186 tributary streams, only 29 (16%) generated alluvial fans at their tributary junctions. The fan-generating catchments possess higher relief, longer lengths, lower gradients, and larger areas than nonfan-generating catchments. Whilst geologically, fan-generating catchments are underlain by folded/steeply dipping weak bedrock conducive to high sediment yield. Tributary-junction fans are built from debris flow or fluvial processes into open or confined canyon trunk valley settings. The proximity of the perennial trunk drainage combined with the valley morphology produces lobate or foreshortened trimmed fan forms. Analysis of fan (area, gradient, process), catchment (area, relief, length, gradient), and tributary valley (width) variables reveals weak morphometric relationships, highlighted by residual plots that show dominance of smaller and lower gradient than expected fan forms. These morphometric relationships can be explained by interplay between the catchment and trunk drainage geology, morphology, climate, and flood regime that are combined into a conceptual 'build and reset' model. Ephemeral tributary-junction fans develop progressively during annual localised winter-spring storm events, attempting to build towards a morphological equilibrium. However, the fans never reach an equilibrium morphological form as they are reset by rare (> 10 year) large floods along the River Dades that are linked to regional incursions of Atlantic low pressure troughs. The model

  8. Viability Analysis of Waste Tires as Material for Rail Vibration and Noise Control in Modern Tram Track Systems

    Directory of Open Access Journals (Sweden)

    Caiyou Zhao

    2015-01-01

    Full Text Available This research study focused on the effect of using damping chamber elements made from waste tires on railway noise reduction. First, the energy absorption characteristics of damping chamber elements with various gradation combinations and compaction indices were measured in the laboratory using compression testing. The laboratory compression results demonstrated that the optimal gradation combination of damping chamber elements is as follows: the content of fine rubber particles is 10%, the content of coarse granules is 90%, and the optimal compaction index is 0.98. Next, the findings from the laboratory compression-test studies were used to produce damping chamber elements that were applied to a full-scale modern track model in the laboratory. The measurements of the dynamic properties indicated that the damping chamber elements could significantly reduce the vibration levels of the rail head. Finally, the damping chamber elements, which had been proven effective through laboratory dynamic tests, were widely applied to test rail sections in the field. The field tests demonstrated that damping chamber elements can significantly increase the track vibration decay rate in the frequency range of 200–10000 Hz. Therefore, damping chamber elements made from waste tires are able to control rail vibration and noise in modern tram track systems.

  9. Development of Computer Software for the Analysis and Design of Modern Control Systems

    Science.gov (United States)

    1989-01-01

    tedious process of generating the graphs by hand. It was the purpose of this thesis to develop computer algorithms to automate this task in a easy to use format. This software is called the Control Systems Software Package (CSSP).

  10. Topical hemostasis: a valuable adjunct to control bleeding in the operating room, with a special focus on thrombin and fibrin sealants.

    Science.gov (United States)

    Doria, Cataldo; Vaccino, Silvia

    2009-02-01

    Achieving surgical hemostasis plays a major role in the operating room. Occasionally, classical surgical techniques are ill suited or fail to achieve the desired control at the site of bleeding. Topical hemostasis may be seen as a useful addition to assist the surgeon in controlling surgical bleeding. To provide a brief overview of available topical hemostatic agents with a focus on the different formulations of thrombin. The scope of the review was limited to a keyword search on PubMed and Ovid (surgical hemostasis, thrombin, tissue adhesives). Proven as adjuncts to surgical hemostasis, topical hemostatic agents have become quite valuable to bridge or to achieve permanent hemostasis.

  11. Design of the control room of the N4-type PWR: main features and feedback operating experience; La salle de commande du palier N4: principales caracteristiques et retour d'experience d'exploitation

    Energy Technology Data Exchange (ETDEWEB)

    Peyrouton, J.M.; Guillas, J.; Nougaret, Ch. [Electricite de France (EDF/DPN/CAPE), 93 - Saint-Denis (France)

    2004-07-01

    This article presents the design, specificities and innovating features of the control room of the N4-type PWR. A brief description of control rooms of previous 900 MW and 1300 MW -type PWR allows us to assess the change. The design of the first control room dates back to 1972, at that time 2 considerations were taken into account: first the design has to be similar to that of control rooms for thermal plants because plant operators were satisfied with it and secondly the normal operating situation has to be privileged to the prejudice of accidental situations just as it was in a thermal plant. The turning point was the TMI accident that showed the weight of human factor in accidental situations in terms of pilot team, training, procedures and the ergonomics of the work station. The impact of TMI can be seen in the design of 1300 MW-type PWR. In the beginning of the eighties EDF decided to launch a study for a complete overhaul of the control room concept, the aim was to continue reducing the human factor risk and to provide a better quality of piloting the plant in any situation. The result is the control room of the N4-type PWR. Today the cumulated feedback experience of N4 control rooms represents more than 20 years over a wide range of situations from normal to incidental, a survey shows that the N4 design has fulfilled its aims. (A.C.)

  12. Quality control and assurance in anesthesia: A necessity of the modern times.

    Science.gov (United States)

    Bajwa, Sukhminder Jit Singh; Jindal, Ravi

    2014-01-01

    The advent of newer developments in anesthesia techniques and current clinical scenario has necessitated assurance of quality anesthesia services delivery. Numerous factors including availability of newer drugs, availability of newer advanced monitoring gadgets, increased awareness among the patient population, implementation of newer medico-legal laws and professional competitiveness has mandated a quality control and assurance in anesthesia. These domains of quality control are adapted from public health and are being incorporated into daily anesthesia practice in a gradual and phased manner. Quality control and assurance can be assessed and measured with certain quality indicators, which are also helpful in determining the perioperative outcome in anesthesia and surgical practice. Patient's perception about various anesthetic procedures, drug effects and recovery state are the prime underlying basis for assessing the quality assurance and control. At the same time, a positive impact of feedback mechanism cannot be under-emphasized while aiming for improvement in delivery of quality anesthesia services. The current review is aimed at highlighting the important aspects associated with quality assurance and quality control in anesthesia practice.

  13. Quality control and assurance in anesthesia: A necessity of the modern times

    Science.gov (United States)

    Bajwa, Sukhminder Jit Singh; Jindal, Ravi

    2014-01-01

    The advent of newer developments in anesthesia techniques and current clinical scenario has necessitated assurance of quality anesthesia services delivery. Numerous factors including availability of newer drugs, availability of newer advanced monitoring gadgets, increased awareness among the patient population, implementation of newer medico-legal laws and professional competitiveness has mandated a quality control and assurance in anesthesia. These domains of quality control are adapted from public health and are being incorporated into daily anesthesia practice in a gradual and phased manner. Quality control and assurance can be assessed and measured with certain quality indicators, which are also helpful in determining the perioperative outcome in anesthesia and surgical practice. Patient's perception about various anesthetic procedures, drug effects and recovery state are the prime underlying basis for assessing the quality assurance and control. At the same time, a positive impact of feedback mechanism cannot be under-emphasized while aiming for improvement in delivery of quality anesthesia services. The current review is aimed at highlighting the important aspects associated with quality assurance and quality control in anesthesia practice. PMID:25886215

  14. WAMS Based Intelligent Operation and Control of Modern Power System with large Scale Renewable Energy Penetration

    DEFF Research Database (Denmark)

    Rather, Zakir Hussain

    power system with least dependence on conventional power plants. An important aspect of WAMS realization in a power system is optimal placement of expensive PMUs in order to realize cost effective and reliable grid state monitoring and control. Coupled with Real time digital simulator (RTDS) based...... of complex power systems. WAMS is rapidly being implemented in power systems across the globe and is seen a means to realize smart grid at transmission system level. This thesis (industrial PhD with kk-electronic) proposes WAMS based methods to intelligently control and operate large scale wind integrated...... to intermittent nature and lack of adequate controllability of wind generation, large scale integration of wind energy compromises the security of power system. Therefore, WAMS based security assessment has been proposed to assess the steady state and dynamic security of large scale wind integrated power system...

  15. Modern approaches of control of spatial organization of schoolchildren body in the process of physical education

    Directory of Open Access Journals (Sweden)

    Bondar O.M.

    2012-08-01

    Full Text Available Technology of control of spatial organization of body of schoolboys is developed. Technology includes the diagnostic, informative and practical stages. Research is oriented to the schoolchildren 7-16 years. The diagnostic stage is supposed by a complex inspection and express control of spatial organization of bodies. The informative stage includes computer treatment of research results. The practical stage consists of development of recommendations on the correction of indexes of spatial organization of body of schoolchildren. Logical component allows to expose the level of knowledge of parents and teachers of physical culture about control of spatial organization of body of schoolchildren. The developed technology allows to carry out timely diagnostics of violations of spatial organization of body of schoolchildren and estimate adequacy of pedagogical influences.

  16. The new ASME consensus on operating practices for the control of feedwater and boilerwater chemistry in modern industrial boilers

    Energy Technology Data Exchange (ETDEWEB)

    Tvedt, T.J. Jr. [Dow Chemical Co., Freeport, TX (United States); Holloway, R.T. [Holloway Associates, Islington, Ontario (Canada)

    1997-09-01

    In 1979 the American Society of Mechanical Engineers first published Consensus on Operating Practices for the Control of Feedwater and Boiler Water Quality in Modern Industrial boilers. This document quickly became accepted throughout the world. However, as time went on, it became apparent that the document needed to be revised and expanded. For example, the use of equipment not addressed in the original document (such as waste heat recovery boilers and electrode boilers) became much more common. Furthermore, the original document never addressed issues such as steam purity. In 1994 the ASME Committee on Water and Steam in Thermal Power Systems reissued the Consensus document which included guidance on these and many other important feedwater and boiler water parameters. This paper will briefly contrast the new document with the original one, then discuss the content of the present document. Numerous examples will be used to illustrate the practices recommended by the ASME committee.

  17. New thinking for the boiler room.

    Science.gov (United States)

    Rose, Wayne

    2008-09-01

    Wayne Rose, marketing manager at integrated plant room manufacturer Armstrong Integrated Systems, explains how increasing use of off-site manufacture, the latest 3D modelling technology, and advances in control technology, are revolutionising boiler room design and construction.

  18. A Parametric Study of Actuator Requirements for Active Turbine Tip Clearance Control of a Modern High Bypass Turbofan Engine

    Science.gov (United States)

    Kratz, Jonathan L.; Chapman, Jeffryes W.; Guo, Ten-Huei

    2017-01-01

    The efficiency of aircraft gas turbine engines is sensitive to the distance between the tips of its turbine blades and its shroud, which serves as its containment structure. Maintaining tighter clearance between these components has been shown to increase turbine efficiency, increase fuel efficiency, and reduce the turbine inlet temperature, and this correlates to a longer time-on-wing for the engine. Therefore, there is a desire to maintain a tight clearance in the turbine, which requires fast response active clearance control. Fast response active tip clearance control will require an actuator to modify the physical or effective tip clearance in the turbine. This paper evaluates the requirements of a generic active turbine tip clearance actuator for a modern commercial aircraft engine using the Commercial Modular Aero-Propulsion System Simulation 40k (C-MAPSS40k) software that has previously been integrated with a dynamic tip clearance model. A parametric study was performed in an attempt to evaluate requirements for control actuators in terms of bandwidth, rate limits, saturation limits, and deadband. Constraints on the weight of the actuation system and some considerations as to the force which the actuator must be capable of exerting and maintaining are also investigated. From the results, the relevant range of the evaluated actuator parameters can be extracted. Some additional discussion is provided on the challenges posed by the tip clearance control problem and the implications for future small core aircraft engines.

  19. Deformable trailing edge flaps for modern megawatt wind turbine controllers using strain gauge sensors

    DEFF Research Database (Denmark)

    Andersen, Peter Bjørn; Henriksen, Lars Christian; Gaunaa, Mac

    2010-01-01

    . By enabling the trailing edge to move independently and quickly along the spanwise position of the blade, local small flutuations in the aerodynamic forces can be alleviated by deformation of the airfoil flap. Strain gauges are used as input for the flap controller, and the effect of placing strain gauges...

  20. 75 FR 76653 - Export Control Modernization: Strategic Trade Authorization License Exception

    Science.gov (United States)

    2010-12-09

    ... or biological weapons (CB); nuclear nonproliferation (NP); regional stability (RS); encryption items... (NP); regional stability (RS); encryption items (EI); crime control (CC), but not ECCNs 0A981, 0A982..., Surinam, Swaziland, Taiwan, Tajikistan, Tanzania, Thailand, Togo, Tonga, Trinidad & Tobago,...

  1. Potential and limitations of modern equipment for real time control of urban wastewater systems

    DEFF Research Database (Denmark)

    Campisano, A.; Cabot Ple, J.; Muschalla, D.

    2013-01-01

    Real Time Control (RTC) has become an accepted technique for improving the performance of Urban Drainage Systems (UDS) due to its flexibility and sustainability. Numerous implementations of RTC have been reported during the last decades. At the same time, guideline documents and state-of-the-art ...

  2. 75 FR 81152 - Export Control Modernization: Strategic Trade Authorization License Exception

    Science.gov (United States)

    2010-12-27

    ... Bureau of Industry and Security 15 CFR Parts 732, 738, 740, 743, 758, and 774 RIN 0694-AF03 Export... error in the address for submitting e-mail comments that appeared in a proposed rule, ``Export Control... comments was incorrectly stated under the ADDRESSES caption of a proposed rule entitled ``Export...

  3. A modern control theory based algorithm for control of the NASA/JPL 70-meter antenna axis servos

    Science.gov (United States)

    Hill, R. E.

    1987-01-01

    A digital computer-based state variable controller was designed and applied to the 70-m antenna axis servos. The general equations and structure of the algorithm and provisions for alternate position error feedback modes to accommodate intertarget slew, encoder referenced tracking, and precision tracking modes are descibed. Development of the discrete time domain control model and computation of estimator and control gain parameters based on closed loop pole placement criteria are discussed. The new algorithm was successfully implemented and tested in the 70-m antenna at Deep Space Network station 63 in Spain.

  4. CONTROLLING AS ORGANIZATIONAL AND METHODICAL COMPLEX OF SUPPORT OF MODERNIZATION AND MANAGEMENT IN THE FIELD OF HEALTH CARE

    Directory of Open Access Journals (Sweden)

    Miroshnichenko M. A.

    2015-03-01

    Full Text Available Justification of the need and the prospects of using controlling in the mechanism of management of a versatile medical center is an actual problem now. The concept of the introduction of controlling, as organizational and methodical complex of support of modernization and management in the field of health care is considered. The analysis of the essence, the tasks and the functions of controlling of medical institution, advantage and possibility of application of controlling in the treatment-and-prophylactic establishment (TAPE in system of administration is given. Controlling is capable to have an impact on adoption of administrative decisions at the different levels. Applications in a management system of LPT of controlling will allow carrying out the following kinds of activity: to study the parameters of administration and to define the quality of the purpose of medical activity and indicators estimating their result; to define the activity in specialty; to develop information support of the administration; to coordinate the process of planning at the level of intermedical and interdisciplinary interaction; to predict the work of LPU; to develop the structure of the accounting of activity which is rather detailed with the definition of the expenses of the work of LPU; to have an opportunity to estimate the work of LPU at the municipal level and at the level of the subject of the Russian Federation; to develop the unified assessment of the ways and the indicators allowing to compare the results of the administration at all stages of medical activity; to use offers on the basis of the analysis and the assessment of planned and registration data on medical activity and to be guided by them when making administrative decisions at various levels of management

  5. Human Engineering Design Criteria for Modern Control/Display Components and Standard Parts.

    Science.gov (United States)

    1980-05-01

    t 1’d PaneI~ I li- 1 2 -0 SAE J585e Motorcycle Turn Signal Lamps SAE J585e Tail Lamps (Rear Position Lamps) SAE J586d Top Lamps SAE J578c Color...Specification for Electric Signal Lighting Devices SAE J588e Turn Signal Lamps SAE J593e Backup Lamps SAE J595b Flashing Warning Lamps for Authorized...Emergency, Maintenance and Service Vehicles SAE J589b Turn Signal Switch SAE J914a Side Turn Signal Lamps FMVSS No. 101 Control Location, Identification and

  6. The modernization of the Russian strategic forces and the future of the US-Russian arms control

    Energy Technology Data Exchange (ETDEWEB)

    Miasnikov, Eugene [The Center for Arms Control, Energy and Environmental Studies at Moscow Institute of Physics and Technology (Russian Federation)

    2007-07-01

    The bilateral U.S.-Russian strategic arms control di alog was at its peak at the end of the Cold War, when the very successful Intermediate Nuclear Forces (INF) and Strategic Arms Reduction (START) Treaties were succeeded. Unfortunately, it is almost non-existent these days. With the end of START in 2009, an important verification mechanism, that currently provides transparency of U.S. and Russian strategic forces and their activities, might be lost, if the sides fail to work out a replacement for it. At the same time the role of transparent nuclear arms reductions by nuclear states is growing for the future of the Nonproliferation Treaty (NPT) regime, and this factor should stimulate U.S. and Russia to renew the strategic arms control dialog. The talk focuses on modern trends in the evolution of U.S. and Russian nuclear forces and doctrines of their implementation as well as on the impact of these tendencies on attitudes toward arms control. A framework of a new bilateral strategic arms reduction agreement that might replace START and enforce Strategic Offensive Reductions Treaty (SORT) is proposed.

  7. Computer and Modernization%Concurrency Control Algorithms with Balanced Blink-tree Database Index

    Institute of Scientific and Technical Information of China (English)

    包斌; 李亚岗

    2016-01-01

    针对B链树作为多版本数据库索引的并发控制机制,提出一种新的B链树结构修改并发控制算法。该算法将B链树结构修改操作划分为几个更小的原子修改操作,这些修改操作可以并发运行并且不会死锁。实验表明,新算法提高了并发度与事务的吞吐量,并保持B链树结构的一致性和平衡性。%Concerning the concurrency control mechanism for multiversion database index based on Blink-tree, a new Blink-tree concurrency control modification algorithm was proposed. The algorithm divides Blink-tree structure modification into several smal-ler atomic modifications which run concurrently and deadlock-free. The experimental results show that the new algorithm improves concurrency and transaction throughput, and retains consistency and balance of Blink-tree structure.

  8. Modernizing methodology for the WHO assessment of substances for the international drug control conventions.

    Science.gov (United States)

    Danenberg, E; Sorge, L A; Wieniawski, W; Elliott, S; Amato, L; Scholten, W K

    2013-08-01

    The WHO Executive Board revised the guidance that governs the procedures for the WHO review of psychoactive substances for international drug control in 2010. To meet the standards defined in these guidelines, the current evaluation methodology at WHO must be an evidence-based assessment. We describe the history of substance evaluation from 1912 to the present and the development of the evaluation methods over time including a description of the current assessment system, using reports from WHO and its predecessor, the League of Nations. Furthermore, we describe the current review system. We found that some substances under international control were never reviewed; other substances were reviewed decades ago. We argue that assessments do not have unlimited validity, and therefore, substances need to be re-assessed periodically, as already recommended by the Expert Committee on Drug Dependence in 1982. We propose that the evaluation time be shortened; that the influence of the route of administration and/or dosage form of the preparation is considered in the evaluation; and we recommend studying national and regional assessment systems and adopting their best practices. With this article, we make a case for the inclusion of systematic review and other methods of comprehensive analysis of substance evaluation to arrive at a process of equal rigour and quality as already applied by WHO for the development of treatment guidelines. Copyright © 2013 World Health Organization. Published by Elsevier Ireland Ltd.. All rights reserved.

  9. A Study on Large Display Panel Design for the Countermeasures against Team Errors within the Main Control Room of APR-1400

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sa Kil; Lee, Yong Hee [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    The personal aspect of human errors has been mainly overcome by virtue of the education and training. However, in the system aspect, the education and training system needs to be reconsidered for more effective reduction of human errors affected from various systems hazards. Traditionally the education and training systems are mainly not focused on team skills such as communication, situational awareness, and coordination, etc. but individual knowledge, skill, and attitude. However, the team factor is one of the crucial issues to reduce the human errors in most industries. In this study, we identify the emerging types of team errors, especially, in digitalized control room of nuclear power plants such as the APR-1400 main control room. Most works in nuclear industry are to be performed by a team of more than two persons. Even though the individual errors can be detected and recovered by the qualified others and/or the well trained team, it is rather seldom that the errors by team could be easily detected and properly recovered by the team itself. Note that the team is defined as two or more people who are appropriately interacting with each other, and the team is a dependent aggregate, which accomplishes a valuable goal. Team error is one of the typical organizational errors that may occur during performing operations in nuclear power plants. The large display panel is a representative feature of digitalized control room. As a group-view display, the large display panel provides plant overview to the operators. However, in terms of team performance and team errors, the large display panel is on a discussion board still because the large display panel was designed just a concept of passive display. In this study, we will propose revised large display panel which is integrated with several alternative interfaces against feasible team errors.

  10. Human-factors engineering control-room design review/audit: Waterford 3 SES Generating Station, Louisiana Power and Light Company

    Energy Technology Data Exchange (ETDEWEB)

    Savage, J.W.

    1983-03-10

    A human factors engineering design review/audit of the Waterford-3 control room was performed at the site on May 10 through May 13, 1982. The report was prepared on the basis of the HFEB's review of the applicant's Preliminary Human Engineering Discrepancy (PHED) report and the human factors engineering design review performed at the site. This design review was carried out by a team from the Human Factors Engineering Branch, Division of Human Factors Safety. The review team was assisted by consultants from Lawrence Livermore National Laboratory (University of California), Livermore, California.

  11. 6 June 2008 - Chancellor F. Tomàs Vert, University of Valencia, visiting ATLAS control room and experimental area with Collaboration Spokesperson P. Jenni.

    CERN Multimedia

    Mona Schweizer

    2008-01-01

    6 June 2008 - Chancellor F. Tomàs Vert, University of Valencia, visiting ATLAS control room and experimental area with Collaboration Spokesperson P. Jenni. Other participants: Prof. Francisco José Botella, Director, Instituto de Fisica Corpuscular, University of València and CSIC Prof. José Peñarrocha, Dean, Faculty of Physics Prof. Antonio Ferrer, Instituto de Fisica Corpuscular, University of València and CSIC Prof. Antonio Pich, University of València, Member of IFIC (CSIC - Univ. València), Coordinator of CPAN, Spanish National Centre for Particle, Astroparticle and Nuclear Physics.

  12. Hydrofluoric Acid Controlled TiO2 Phase Transformation from Rutile to Anatase at Room Temperature and Their Photocatalytic Performance.

    Science.gov (United States)

    Ge, Suxiang; Li, Dapeng; Jia, Gaoyang; Wang, Beibei; Yang, Zhen; Yang, Zongyang; Qiao, Hui; Zhang, Yange; Zheng, Zhi

    2015-09-01

    In this study, we first present rutile TiO2 superstructures could be successfully transformed into anatase TiO2 nanoparticles at room temperature by adjusting the amount of hydrofluoric acid (HF) used in aqueous solution. Photocatalytic experiments demonstrated that the as prepared anatase TiO2 exhibited better photocatalytic performance than that of rutile TiO2. We further studied the photocatalytic degradation of RhB on different TiO2 via active species trapping experiments and confirmed that the presence of surface F- on TiO2 was beneficial for the formation of *OH, which was thought to be mainly responsible for the enhancement of photocatalytic performance.

  13. EFFECTS OF DIFFERENT FUNCTIONAL GROUP-CONTAINING ORGANICS ON MORPHOLOGY-CONTROLLED SYNTHESIS OF SILVER NANOPARTICLES AT ROOM TEMPERATURE

    Institute of Scientific and Technical Information of China (English)

    A.L. Wang; H.B. Yin; M. Ren; X.N. Cheng; Q.F. Zhou; X.F. Zhang

    2006-01-01

    Silver nanoparticles with average particles sizes ranging from 2 to 131nm were manipulatively synthesized starting from silver nitrate using different functional group-containing organic modifiers at room temperature. The effects of the organic modifiers on the morphology of the resulting silver nanoparticles were strongly dependent on the intrinsic properties of the functional groups and the reducibility of the reductant. Numerous ether bonds (-O-) present in polyethylene glycol and Tween-80 were beneficial to the formation of silver nanoparticles with particle sizes of several nanometers in a narrow size distribution in both weak and strong reducing environments.Cetyltrimethylammonium bromide induced the formation of nanosized silver triangle plates in a weak reducing environment. The crystal growth of the silver nanoparticles with particle sizes of more than 10nm was postulated through an adhesion process of small-sized particles followed by a subsequent coalescence process under the present reaction conditions.

  14. Modern techniques for the emissions control in thermal electric stations; Tecnicas modernas para el control de emisiones en centrales termoelectricas

    Energy Technology Data Exchange (ETDEWEB)

    Romo Millares, C. A. [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1995-12-31

    This paper presents the techniques and the control equipment for emissions in thermal stations that have the highest possibilities of being considered in the immediate future in the national energy panorama and the established frame for the environmental normativity. The pollutant compounds subject to revision are the nitrogen and sulfur oxides and unburned particles. [Espanol] Se presentan las tecnicas y equipos de control de emisiones para centrales termoelectricas que tienen mayores posibilidades de ser consideradas en el futuro inmediato dentro del panorama energetico nacional y el marco establecido por la normatividad ambiental. Los compuestos contaminantes sujetos a revision son los oxidos de nitrogeno y azufre y las particulas inquemadas.

  15. Study and Development of a Simulation System for Dynamic Evaluation on Man-machine Interface Design of Advanced Main Control Rooms of Nuclear Power Plants

    Institute of Scientific and Technical Information of China (English)

    YangXiaojing; ZhouZhiwei; ChenXiaoming; MaYuanle; LiFu; DongYujie; WuWei; OhiTadashi

    2005-01-01

    Since the man-machine interfaces (MMI) of a main control room provide the control platform of a nuclear power plant (NPP),the development of the design quality of MMIs plays a very important role in the operation of a NPP. With the development of digital technology, the development of the advanced main control rooms (AMCRs) has become an inexorable trend. Therefore, the positive and the negative effects of AMCRs on human factors engineering need to be evaluated. For this p~, a simulation system has been studied and developed to quantitatively evaluate a MMI design from the viewpoint of human factors. The simulation system takes advantage of computer simulation technology to simulate an operating process of an interaction between operators and a MMI design under an instruction of an operation procedure of the AMCR of a NPP. Meanwhile, the necessary data are recorded for evaluation. It integrates two editors and one simulator. In the paper, the simulation system is presented in detail. Furthermore, one sample is given to show the results of each of these three subsystems.

  16. Bureau-repression: Administrative Sanction and Social Control in Modern Spain

    Directory of Open Access Journals (Sweden)

    Pedro Oliver Olmo

    2015-12-01

    Full Text Available This paper explains the creation of an intelligible suggestion for better understanding the administrative sanction in many disciplines in social sciences: the bureau-repression. The coining of this concept is due especially to the repression to which social protestors and demonstrators have been subject since the birth of the 15-M movement in Spain. However, bureau-repression had already begun being exercised in the years following the Transition, and it has developed in parallel to the stage of Security State that characterizes the state system of social control. A detailed analysis of the administrative sanction is performed for many benefits which such sanction provides for those in power, who use it both to silence voices from the street and to dispose of elements which are harmful for the neoliberal system (disadvantaged groups or immigrants. In short, the reader will find the underlying political and repressive background which, at first glance, is usually a monetary fine, and will discover that there are ways to avoid this dense surveillance exercised over the governed people (bureau-resistance. Este artículo explica la creación de una sugerencia inteligible para una mejor comprensión de la sanción administrativa en muchas disciplinas de las ciencias sociales: la burorrepresión. Este término nació especialmente a raíz de la represión que han sufrido los manifestantes de las protestas sociales desde el nacimiento del movimiento 15-M en España. Sin embargo, la burorrepresión ya había comenzado a ejercerse en los años que siguieron a la Transición, y se ha desarrollado de forma paralela al estado de seguridad que caracteriza el sistema estatal de control social. Se realiza un análisis detallado de la sanción administrativa, desarrollada en beneficio de los que están en el poder, quienes la usan tanto para silenciar las voces de la calle como para deshacerse de elementos que sean perjudiciales para el sistema neoliberal

  17. Legitimacy and modernity via policy transfer: the utility of the 2003 Afghan National Drug Control Strategy.

    Science.gov (United States)

    Bewley-Taylor, David R

    2014-09-01

    Very much an exercise in historical reconstruction, this article is concerned with the development of the first version of the Afghan NDCS. It is hoped that this domain of enquiry will contribute to discussions around the 'governance of drug policy' in this special issue of the International Journal of Drug Policy by focusing on how different policy actors operate in influencing the policy process; or parts thereof. More specifically, exploration of the formulation of the Strategy does much to help us understand not only the origins and shifting nature of ownership of drug policy within Afghanistan but also the relationship between the NDCS and the broader normative expectations of what has been referred to as the global drug prohibition regime (Andreas & Nadelmann, 2006, p. 38). As will be discussed, while indisputably the product of a process of policy transfer involving a number of non-Afghan actors - and as such arguably not always appropriate to the peculiarities of the drug market within the country - it can be argued that the 2003 National Drug Control Strategy fulfilled a useful functional role that in many ways exceeded its utility as a guiding document beyond the confines of Kabul. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Modern contact investigation methods for enhancing tuberculosis control in Aboriginal communities

    Directory of Open Access Journals (Sweden)

    Victoria J. Cook

    2012-05-01

    Full Text Available The Aboriginal communities in Canada are challenged by a disproportionate burden of TB infection and disease. Contact investigation (CI guidelines exist but these strategies do not take into account the unique social structure of different populations. Because of the limitations of traditional CI, new approaches are under investigation and include the use of social network analysis, geographic information systems and genomics, in addition to the widespread use of genotyping to better understand TB transmission. Guidelines for the routine use of network methods and other novel methodologies for TB CI and outbreak investigation do not exist despite the gathering evidence that these approaches can positively impact TB control efforts, even in Aboriginal communities. The feasibility and efficacy of these novel approaches to CI in Aboriginal communities requires further investigation. The successful integration of these novel methodologies will require community involvement, capacity building and ongoing support at every level. The outcome will not only be the systematic collection, analysis, and interpretation of CI data in high-burden communities to assess transmission but the prioritization of contacts who are candidates for treatment of LTBI which will break the cycle of transmission. Ultimately, the measure of success will be a clear and sustained decline in TB incidence in Aboriginal communities.

  19. Proposal for the award of a contract for the design, supply, installation and commissioning of a Heating, Ventilation and Air-Conditioning (HVAC) system for the computer room of the CERN Control Centre

    CERN Document Server

    2012-01-01

    Proposal for the award of a contract for the design, supply, installation and commissioning of a Heating, Ventilation and Air-Conditioning (HVAC) system for the computer room of the CERN Control Centre

  20. 4th February 2011- Polish Ambassador to the United Nations Office R. A. Henczel visiting CMS control room and underground experimental area with his daughter, guided by Collaboration Spokesperson G. Tonelli.

    CERN Multimedia

    Maximilien Brice

    2011-01-01

    4th February 2011- Polish Ambassador to the United Nations Office R. A. Henczel visiting CMS control room and underground experimental area with his daughter, guided by Collaboration Spokesperson G. Tonelli.

  1. 19 September 2012 - Indonesian Members of Parliament visiting the CMS control room and experimental cavern at Point 5 with Former Deputy Spokesperson A. De Roeck and International Relations Adviser E. Tsesmelis.

    CERN Document Server

    Jean-Claude Gadmer

    2012-01-01

    19 September 2012 - Indonesian Members of Parliament visiting the CMS control room and experimental cavern at Point 5 with Former Deputy Spokesperson A. De Roeck and International Relations Adviser E. Tsesmelis.

  2. Controversies in modern evolutionary biology: the imperative for error detection and quality control

    Directory of Open Access Journals (Sweden)

    Prosdocimi Francisco

    2012-01-01

    Full Text Available Abstract Background The data from high throughput genomics technologies provide unique opportunities for studies of complex biological systems, but also pose many new challenges. The shift to the genome scale in evolutionary biology, for example, has led to many interesting, but often controversial studies. It has been suggested that part of the conflict may be due to errors in the initial sequences. Most gene sequences are predicted by bioinformatics programs and a number of quality issues have been raised, concerning DNA sequencing errors or badly predicted coding regions, particularly in eukaryotes. Results We investigated the impact of these errors on evolutionary studies and specifically on the identification of important genetic events. We focused on the detection of asymmetric evolution after duplication, which has been the subject of controversy recently. Using the human genome as a reference, we established a reliable set of 688 duplicated genes in 13 complete vertebrate genomes, where significantly different evolutionary rates are observed. We estimated the rates at which protein sequence errors occur and are accumulated in the higher-level analyses. We showed that the majority of the detected events (57% are in fact artifacts due to the putative erroneous sequences and that these artifacts are sufficient to mask the true functional significance of the events. Conclusions Initial errors are accumulated throughout the evolutionary analysis, generating artificially high rates of event predictions and leading to substantial uncertainty in the conclusions. This study emphasizes the urgent need for error detection and quality control strategies in order to efficiently extract knowledge from the new genome data.

  3. Modern processes controlling the sea bed sediment formation in Barents Sea

    Science.gov (United States)

    Balanyuk, I.; Dmitrievsky, A.; Shapovalov, S.; Chaikina, O.; Akivis, T.

    2009-04-01

    terrigenous matter settles in natural sediment traps of fjords. The Barents Sea bottom has rather dissected relief. A number of isometric or, rarer, elongated underwater elevations (Perseus, Central, the Admiralty Bar, the Goose shoal) and separation trenches and troughs (South and North Barents Sea troughs, Perseus, Aldanov, Medvezhinsky, Franz Victoria, West and South Novozemelsky trenches) can be distinguished. The major processes that control a structure of the friable sedimentary cover of Arctic shelves appear on the seismic acoustic records as chaotic effect of cryolithogenesis (permafrost, themokarst, thawed patches, paleoriverbeds, etc.) and hydrocarbons migration (gas hydrates, gas saturated sediments, gas seeping, porkmarks, etc). Such phenomena are the main components of geo-risks for oil and gas fields development in Arctic Seas and are, together with the gas hydrates deposits, the top priority objects of seismic acoustic measurements. The shelf of the Barents Sea is one of the most extensively studied with high resolution acoustic methods because of large-scale engineering and geological problems solved in process of its industrial development. Mainly, it is related to exploring and development of oil and gas fields, oil terminals and submarine pipelines construction, and building up the whole infrastructure for their exploitation.

  4. Human errors and work performance in a nuclear power plant control room: associations with work-related factors and behavioral coping

    Energy Technology Data Exchange (ETDEWEB)

    Kecklund, L.J. [Swedish Nuclear Power Inspectorate, Stockholm (Sweden).Dept. of Man-Technology Organization; Svenson, O. [Stockholm University (Sweden). Dept. of Psychology

    1997-12-01

    The present study investigated the relationships between the operator`s appraisal of his own work situation and the quality of his own work performance, as well as self-reported errors in a nuclear power plant control room. In all, 98 control room operators from two nuclear power units filled out a questionnaire and several diaries during two operational conditions, annual outage and normal operation. As expected, the operators reported higher work demands in annual outage as compared to normal operation. In response to the increased demands, the operators reported that they used coping strategies such as increased effort, decreased aspiration level for work performance quality, and increased use of delegation of tasks to others. This way of coping does not reflect less positive motivation for the work during the outage period. Instead, the operators maintain the same positive motivation for their work, and succeed in being more alert during morning and night shifts. However, the operators feel less satisfied with their work result. The operators also perceive the risk of making minor errors as increasing during outage. (Author).

  5. Modernity: Are Modern Times Different?

    Directory of Open Access Journals (Sweden)

    Lynn Hunt

    2014-12-01

    Full Text Available “Modernity” has recently been the subject of considerable discussion among historians. This article reviews some of the debates and argues that modernity is a problematic concept because it implies a complete rupture with “traditional” ways of life. Studies of key terms are undertaken with the aid of Google Ngrams. These show that “modernity,” “modern times,” and “traditional” —in English and other languages— have a history of their own. A brief analysis of the shift from a self oriented toward equilibrium to a self oriented toward stimulation demonstrates that modernity is not necessary to historical analysis.

  6. Sequential introduction of single room isolation and hand hygiene campaign in the control of methicillin-resistant Staphylococcus aureus in intensive care unit

    Directory of Open Access Journals (Sweden)

    Cheng Vincent CC

    2010-09-01

    Full Text Available Abstract Background After renovation of the adult intensive care unit (ICU with installation of ten single rooms, an enhanced infection control program was conducted to control the spread of methicillin-resistant Staphylococcus aureus (MRSA in our hospital. Methods Since the ICU renovation, all patients colonized or infected with MRSA were nursed in single rooms with contact precautions. The incidence of MRSA infection in the ICU was monitored during 3 different phases: the baseline period (phase 1; after ICU renovation (phase 2 and after implementation of a hand hygiene campaign with alcohol-based hand rub (phase 3. Patients infected with extended spectrum beta-lactamase (ESBL-producing Escherichia coli and Klebsiella species were chosen as controls because they were managed in open cubicles with standard precautions. Results Without a major change in bed occupancy rate, nursing workforce, or the protocol of environmental cleansing throughout the study period, a stepwise reduction in ICU onset nonbacteraemic MRSA infection was observed: from 3.54 (phase 1 to 2.26 (phase 2, p = 0.042 and 1.02 (phase 3, p = 0.006 per 1000-patient-days. ICU onset bacteraemic MRSA infection was significantly reduced from 1.94 (phase 1 to 0.9 (phase 2, p = 0.005 and 0.28 (phase 3, p = 0.021 per 1000-patient-days. Infection due to ESBL-producing organisms did not show a corresponding reduction. The usage density of broad-spectrum antibiotics and fluoroquinolones increased from phase 1 to 3. However a significant trend improvement of ICU onset MRSA infection by segmented regression analysis can only be demonstrated when comparison was made before and after the severe acute respiratory syndrome (SARS epidemic. This suggests that the deaths of fellow healthcare workers from an occupational acquired infection had an overwhelming effect on their compliance with infection control measures. Conclusion Provision of single room isolation facilities and promotion of hand

  7. Distance Perception in a loudspeaker-based room auralization system

    DEFF Research Database (Denmark)

    Favrot, Sylvain Emmanuel; Buchholz, Jörg

    2009-01-01

    A loudspeaker-based room auralization (LoRA) system has been recently proposed that efficiently combines modern room acoustic modeling techniques with high-order Ambisonics (HOA) auralization to generate virtual auditory environments (VAEs). The reproduction of the distance of sound events...... in such VAE is very important for its fidelity. A direct-scaling distance perception experiment was conducted to evaluate the LoRA system including the use of near-field control (NFC) for HOA. Experimental results showed that (i) loudspeaker-based auralization in the LoRA system provides similar distance...... perception to that of the corresponding real environment and that (ii) NFC-HOA provides a significant increase in the range of perceived distances for near sound sources as compared to standard HOA....

  8. DESIGNING OF SIMULATION FOR ENGINE ROOM KM. SINABUNG WITH CONTROL MONITORING WEB SERVER BASED BY WIRELESS NETWORK AND POWER LINE COMMUNICATION

    Directory of Open Access Journals (Sweden)

    Eko Sasmito Hadi

    2013-06-01

    Full Text Available Engine room monitoring control system is monitoring and controlling main engine and auxiliary engine from long distance by powerline communication network and wireless network to ease the operator in operating the ship and save operational cost. To prevent error in programming the main engine and auxiliary engine, a simulation using instrument software is needed to know the machine characteristic. After simulation result fulfills the requirement which is approached the value of test record, it can be applied to the real machine. In this study, some  steps were done such as: getting know type of main engine and auxiliary engine which performance will be simulated and programmed, getting test record of main engine and auxiliary engine, getting know how the main engine and auxiliary engine work, making simulation of main engine and auxiliary engine work system, doing monitoring control simulation by powerline   communication and wireless network, comparing the results between simulation and test record of main engine and auxiliary engine. Engine programming can be set after simulation result meets the requirement. Result of simulation fulfills the requirement, the difference values between machine simulation using software instrument and test record of main engine and auxiliary engine are around 1%-2%. If engine room monitoring control system by wireless and powerline communication is applied in the ship, the ship owner will get advantages because it will prolong ship durability and can monitor operasional of main engine or Auxiliary engine from long distance ; while the operator will be easier in operating the ship. The disadvantage is only the higher cost

  9. Operating room discharge after deep neuromuscular block reversed with sugammadex compared with shallow block reversed with neostigmine: a randomized controlled trial.

    Science.gov (United States)

    Putz, Laurie; Dransart, Christophe; Jamart, Jacques; Marotta, Maria-Laura; Delnooz, Geraldine; Dubois, Philippe E

    2016-12-01

    To determine if reversing a deep or moderate block with sugammadex, compared with a shallow block reversed with neostigmine, reduces the time to operating room discharge after surgery and the time spent in the postanesthesia care unit. A randomized controlled trial. Monocentric study performed from February 2011 until May 2012. One hundred consenting women with American Society of Anesthesiologists grade I or II were randomized into 2 groups. Laparoscopic hysterectomy was performed under desflurane general anesthesia. For the neostigmine (N) group, 0.45 mg · kg(-1) rocuronium was followed by spontaneous recovery. A 5-mg rescue bolus was administered only if surgical evaluation was unacceptable. At the end of surgery, 50 μg · kg(-1) neostigmine with glycopyrrolate was administered. For the sugammadex (S) group, a higher intubating rocuronium dose (0.6 mg · kg(-1)) was followed by 5-mg boluses each time the train-of-four count exceeded 2. Sugammadex (2-4 mg · kg(-1)) was administered to reverse the block. All patients were extubated after obtaining a train-of-four ratio of 0.9. The duration between the end of surgery and operating room discharge and the time spent in the postanesthesia care unit. The time till operating room discharge was shorter and more predictable in group S (9.15±4.28 minutes vs 13.87±11.43 minutes in group N; P=.005). The maximal duration in group S was 22 minutes, compared with 72 minutes in group N. The time spent in the postanesthesia care unit was not significantly different (group S: 47.75±31.77 minutes and group N: 53.43±40.57 minutes; P=.543). Maintaining a deep neuromuscular block during laparoscopic hysterectomy reversed at the end of the procedure with sugammadex enabled a faster and more predictable time till operating room discharge than did the classical combination of a shallower block reversed with neostigmine. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. A Comparison between Temperature-Controlled Laminar Airflow Device and a Room Air-Cleaner in Reducing Exposure to Particles While Asleep

    Science.gov (United States)

    Spilak, Michal P.; Sigsgaard, Torben; Takai, Hisamitsu; Zhang, Guoqiang

    2016-01-01

    People spend approximately one third of their life sleeping. Exposure to pollutants in the sleep environment often leads to a variety of adverse health effects, such as development and exacerbation of asthma. Avoiding exposure to these pollutants by providing a sufficient air quality in the sleep environment might be a feasible method to alleviate these health symptoms. We performed full-scale laboratory measurements using a thermal manikin positioned on an experimental bed. Three ventilation settings were tested: with no filtration system operated, use of portable air cleaner and use of a temperature-controlled laminar airflow (TLA) device. The first part of the experiment investigated the air-flow characteristics in the breathing zone. In the second part, particle removal efficiency was estimated. Measured in the breathing zone, the room air cleaner demonstrated high turbulence intensity, high velocity and turbulence diffusivity level, with a particle reduction rate of 52% compared to baseline after 30 minutes. The TLA device delivered a laminar airflow to the breathing zone with a reduction rate of 99.5%. During a periodical duvet lifting mimicking a subject’s movement in bed, the particle concentration was significantly lower with the TLA device compared to the room air cleaner. The TLA device provided a barrier which significantly reduced the introduction of airborne particles into the breathing zone. Further studies should be conducted for the understanding of the transport of resuspended particles between the duvet and the laying body. PMID:27898693

  11. Modern isotope hydrology and controls on δD of plant leaf waxes at Lake El'gygytgyn, NE Russia

    Directory of Open Access Journals (Sweden)

    S. Petsch

    2012-08-01

    Full Text Available Stable isotope data from lipid biomarkers and diatom silica recovered from lake sediment cores hold great promise for paleoclimate and paleohydrological reconstructions. However, these records rely on accurate calibration with modern precipitation and hydrologic processes. Here we investigate the stable isotopic composition of modern precipitation, streams, lake water and ice cover, and use these data to constrain isotope systematics of the Lake El'gygytgyn basin hydrology. Compound specific hydrogen isotope ratios determined from modern vegetation are compared with modern precipitation and lake core top sediments. Multi-species net (apparent fractionation values between source water (precipitation and leaf wax lipids (mean value is −105 ± 13‰ agree with previous results in arid environments and provide a basis for application of this proxy downcore. We conclude that although there may be some bias towards winter precipitation signal, overall leaf wax lipids record annual average precipitation within the El'gygytgyn Basin.

  12. Modern algebra

    CERN Document Server

    Warner, Seth

    1990-01-01

    Standard text provides an exceptionally comprehensive treatment of every aspect of modern algebra. Explores algebraic structures, rings and fields, vector spaces, polynomials, linear operators, much more. Over 1,300 exercises. 1965 edition.

  13. Behavioural Modernity

    OpenAIRE

    McLean, Laura

    2015-01-01

    Behavioural Modernity explores the changing politics of representation and ethics of care in curatorial practice, necessitated by an increasing blurring of boundaries between the human, the technological, and the planetary.

  14. Modernity's Prometheus.

    Science.gov (United States)

    Morris, Richard

    1993-01-01

    Argues for reframing and reforging the relationship between text and context. Argues that the silences that modernity's tribute to text invites are grotesque, untenable, and fundamentally anti-intellectual. (SR)

  15. Modernity's Prometheus.

    Science.gov (United States)

    Morris, Richard

    1993-01-01

    Argues for reframing and reforging the relationship between text and context. Argues that the silences that modernity's tribute to text invites are grotesque, untenable, and fundamentally anti-intellectual. (SR)

  16. Automation of room temperature control and heating cost distribution and components for further development; Automatisierung der Raumtemperaturregelung und Heizkostenverteilung sowie Komponenten ihrer Weiterentwicklung

    Energy Technology Data Exchange (ETDEWEB)

    Riedel, M.; Bentscheff, S. [Dr. Riedel Automatisierungstechnik GmbH, Berlin (Germany)

    1997-12-31

    The paper studies how much heat energy can be saved in buildings connected to the district heat grid by using an innovative automation system. This system not only permits to cut down energy consumption; it reduces service and administrative effort as well and enhances comfort. It helps to control the temperature of individual rooms, measure heat energy consumption in detail, and allocate heating costs. In 15 000 residential units this system is already in use. (MSK) [Deutsch] Die Untersuchung zielt auf das Einsparpotential an Heizwaerme in fernwaermeversorgten Gebaeuden bei Einsatz eines innovativen Automatisierungssystems. Neben der Reduktion des Energieverbrauchs ermoeglicht das System eine Reduktion des Service- und Verwaltungsaufwands und eine Erhoehung des Komforts. Es dient sowohl der Einzelraum-Temperaturregelung und der detaillierten Messung der Heizwaermebverbraeuche als auch der Heizkostenverteilung. Derzeit wird das System bereits in 15000 Wohungen eingesetzt.

  17. Evaluation of training programs and entry-level qualifications for nuclear-power-plant control-room personnel based on the systems approach to training

    Energy Technology Data Exchange (ETDEWEB)

    Haas, P M; Selby, D L; Hanley, M J; Mercer, R T

    1983-09-01

    This report summarizes results of research sponsored by the US Nuclear Regulatory Commission (NRC) Office of Nuclear Regulatory Research to initiate the use of the Systems Approach to Training in the evaluation of training programs and entry level qualifications for nuclear power plant (NPP) personnel. Variables (performance shaping factors) of potential importance to personnel selection and training are identified, and research to more rigorously define an operationally useful taxonomy of those variables is recommended. A high-level model of the Systems Approach to Training for use in the nuclear industry, which could serve as a model for NRC evaluation of industry programs, is presented. The model is consistent with current publically stated NRC policy, with the approach being followed by the Institute for Nuclear Power Operations, and with current training technology. Checklists to be used by NRC evaluators to assess training programs for NPP control-room personnel are proposed which are based on this model.

  18. Brief introduction of control of nosocomial infections in blood transfusion room%医院输血科医源性感染控制的管理

    Institute of Scientific and Technical Information of China (English)

    徐兰

    2012-01-01

    OBJECTIVE To control the nosocomial infections in the blood transfusion room and prevent the nosocomial infections. METHODS The administration of hospital infection was strengthened, the reasonable rules and regulations were completed, the training about hospital infection was conducted well, the self-protection consciousness was improved, the detection of infection before transfusion was performed conscientiously, the health records were set up, the protective measures for the staff were stressed, the environment and iceboxes were kept sterilized, and the classification and decontamination of the medical waste were carried out. RESULTS By the measures and management mentioned above, the nosocomial infections in blood transfusion room has been under control in a maximum manner, which therefore ensured the safety and health of the staff. CONCLUSION The nosocomial infections in the blood transfusion room can be prevented by completing reasonable rules and regulations as well as strengthening the training and management.%目的 控制输血科医源性感染的发生,杜绝医院感染.方法 加强医院感染的管理,健全合理的规章制度,做好医院感染培训,增强自我保护意识,认真做好输血前传染病的监测,建立工作人员健康记录,加强工作人员的防护措施、环境以及冰箱的消毒、废弃物的分类和无害化处理等措施.结果 通过上述各项措施和管理,最大限度控制了输血科内的医源性感染,保障了工作人员的安全和身体健康.结论 健全各项规章制度,加强培训和管理,可以预防输血科内医源性感染事件的发生.

  19. Human errors and work performance in a nuclear power plant control room: associations with work-related factors and behavioral coping

    Energy Technology Data Exchange (ETDEWEB)

    Kecklund, Lena Jacobsson; Svenson, Ola

    1997-04-01

    The present study investigated the relationships between the operator's appraisal of his own work situation and the quality of his own work performance as well as self-reported errors in a nuclear power plant control room. In all, 98 control room operators from two nuclear power units filled out a questionnaire and several diaries during two operational conditions, annual outage and normal operation. As expected, the operators reported higher work demands in annual outage as compared to normal operation. In response to the increased demands, the operators reported that they used coping strategies such as increased effort, decreased aspiration level for work performance quality and increased use of delegation of tasks to others. This way of coping does not reflect less positive motivation for the work during the outage period. Instead, the operators maintain the same positive motivation for their work, and succeed in being more alert during morning and night shifts. However, the operators feel less satisfied with their work result. The operators also perceive the risk of making minor errors as increasing during outage. The decreased level of satisfaction with work result during outage is a fact despite the lowering of aspiration level for work performance quality during outage. In order to decrease relative frequencies for minor errors, special attention should be given to reduce work demands, such as time pressure and memory demands. In order to decrease misinterpretation errors special attention should be given to organizational factors such as planning and shift turnovers in addition to training. In summary, the outage period seems to be a significantly more vulnerable window in the management of a nuclear power plant than the normal power production state. Thus, an increased focus on the outage period and human factors issues, addressing the synergetic effects or work demands, organizational factors and coping resources is an important area for improvement

  20. Laboratory, semi-pilot and room scale study of nitrite and molybdate mediated control of H(2)S emission from swine manure.

    Science.gov (United States)

    Moreno, Lyman; Predicala, Bernardo; Nemati, Mehdi

    2010-04-01

    The effects of manure age on emission of H(2)S and required level of nitrite or molybdate to control these emissions were investigated in the present work. Molybdate mediated control of H(2)S emission was also studied in semi-pilot scale open systems, and in specifically designed chambers which simulated swine production rooms. With fresh 1-, 3- and 6-month old manures average H(2)S concentration in the headspace gas of the closed systems were 4856+/-460, 3431+/-208, 1037+/-98 ppm and non-detectable, respectively. Moreover, the level of nitrite or molybdate required to control the emission of H(2)S decreased as manure age increased. In the semi-pilot scale open system and chambers, average H(2)S concentration at the surface of agitated fresh manure were 831+/-26 and 88.4+/-5.7 ppm, respectively. Furthermore, 0.1-0.25 mM molybdate was sufficient to control the emission of H(2)S. A cost study for an average size swine operation showed that the cost of treatment with molybdate was less than 1% of the overall production cost for each market hog.

  1. Hemodialysis Room Nursing Management to Control Hospital Infection%血透室的护理管理对控制医院感染的研究

    Institute of Scientific and Technical Information of China (English)

    张春梅

    2015-01-01

    Objective Study the hemodialysis room after the nursing management in the clinical effect of controlling hospi-tal infection. Methods Hemodialysis in our hospital room to implement a full range of nursing management, develop com-prehensive nursing management measures, implementation of responsibility system, implement to every aspect, to strengthen the work responsibility, strict enforcement of rules and regulations establishment; Observation of hospital infection rates be-fore and after the nursing management, nursing quality and security department score, the indicators qualified rate, and so on and so forth. Results Hemodialysis room implement nursing management of nursing quality and nursing safety score sig-nificantly better than that of nursing management, nursing management after hemodialysis room of the hospital infection rate was significantly lower than 1.8% 12.5% before nursing management, nursing management after hemodialysis room in air quality, disinfectant, hand hygiene and qualified before the instrument is superior to use nursing management, the results with statistical difference (P<0.05). Conclusion Hemodialysis chamber adopts nursing management,effectively reduce the hospital infection rate,improve the effect of the clinical care,to ensure the safety of the patient's health is significant,worthy of clinical application and promotion.%目的 研究血透室实施护理管理后在控制医院感染方面的临床效果. 方法 对该院血透室实施全方位的护理管理,制定全面的护理管理措施,实施责任制,落实到各个方面,强化工作责任,严格执行建全的规章制度;观察护理管理实施前后医院的感染发生率、科室护理质量和安全评分、各项指标合格率等情况. 结果 血透室实施护理管理后的护理质量、护理安全评分显著优于护理管理前,护理管理后血透室的医院感染率1.8%显著低于护理管理前的12.5%,护理管理后血透室在空气质量、消

  2. Modernization of the feedwater heaters control level of the Almaraz I Nuclear Power Plant by OVATION system; Modernizacion del control de nivel de los calentadores de agua de alimentacion de C.N. Almaraz I mediante el sistema OVATION

    Energy Technology Data Exchange (ETDEWEB)

    Madronal Rodriguez, E.; Cabrero Munoz, J. E.

    2010-07-01

    As a result of the process of technological renovation of the heaters system and the power increase project, Almaraz Nuclear Power Plant has made several design changes in the feedwater heaters system. Within these changes, the old heaters control loops are replaced because the new power will increase the heaters drainage caudal. This modernization is carried out using the OVATION control system.

  3. A preliminary user-friendly, digital console for the control room parameters supervision in old-generation Nuclear Plants

    Energy Technology Data Exchange (ETDEWEB)

    Memmi, F.; Falconi, L.; Cappelli, M.; Palomba, M.; Santoro, E.; Bove, R.; Sepielli, M. [UTFISST, ENEA Casaccia, via Anguillarese 301, Rome (Italy)

    2012-07-01

    Improvements in the awareness of a system status is an essential requirement to achieve safety in every kind of plant. In particular, in the case of Nuclear Power Plants (NPPs), a progress is crucial to enhance the Human Machine Interface (HMI) in order to optimize monitoring and analyzing processes of NPP operational states. Firstly, as old-fashioned plants are concerned, an upgrading of the whole console instrumentation is desirable in order to replace an analog visualization with a full-digital system. In this work, we present a novel instrument able to interface the control console of a nuclear reactor, developed by using CompactRio, a National Instruments embedded architecture and its dedicated programming language. This real-time industrial controller composed by a real-time processor and FPGA modules has been programmed to visualize the parameters coming from the reactor, and to storage and reproduce significant conditions anytime. This choice has been made on the basis of the FPGA properties: high reliability, determinism, true parallelism and re-configurability, achieved by a simple programming method, based on LabVIEW real-time environment. The system architecture exploits the FPGA capabilities of implementing custom timing and triggering, hardware-based analysis and co-processing, and highest performance control algorithms. Data stored during the supervisory phase can be reproduced by loading data from a measurement file, re-enacting worthwhile operations or conditions. The system has been thought to be used in three different modes, namely Log File Mode, Supervisory Mode and Simulation Mode. The proposed system can be considered as a first step to develop a more complete Decision Support System (DSS): indeed this work is part of a wider project that includes the elaboration of intelligent agents and meta-theory approaches. A synoptic has been created to monitor every kind of action on the plant through an intuitive sight. Furthermore, another important

  4. Thermochronology of the modern Indus River bedload: New insight into the controls on the marine stratigraphic record

    OpenAIRE

    P. D. Clift; Campbell, I. H.; Pringle, M.S.; Carter, A; Zhang, X.; Hodges, K.V.; Khan, A A; Allen, C.M.

    2004-01-01

    The Indus River is the only major drainage in the western Himalaya and delivers a long geological record of continental erosion to the Arabian Sea, which may be deciphered and used to reconstruct orogenic growth if the modern bedload can be related to the mountains. In this study we collected thermochronologic data from river sediment collected near the modern delta. U-Pb ages of zircons spanning 3 Gyr show that only ∼5% of the eroding crust has been generated since India-Asia collision. The ...

  5. An optimal deterministic control policy of servers in front and back rooms with a variable number of switching points and switching costs

    Institute of Scientific and Technical Information of China (English)

    WANG JiaMin

    2009-01-01

    In this paper we consider a retail service facility with cross-trained workers who can perform operations in both the front room and back room. Workers are brought from the back room to the front room and vice versa depending on the number of customers in the system. A loss of productivity occurs when a worker returns to the back room. Two problems are studied. In the first problem, given the number of workers available, we determine an optimal deterministic switching policy so that the expected number of customers in queue is minimized subject to a constraint ensuring that there is a sufficient workforce to fulfill the functions in the back room. In the second problem, the number of workers needed is minimized subject to an additional constraint requiring that the expected number of customers waiting in queue is bounded above by a given threshold value. Exact solution procedures are developed and illustrative numerical examples are presented.

  6. Enhanced room temperature ferromagnetism in electrodeposited Co-doped ZnO nanostructured thin films by controlling the oxygen vacancy defects

    Energy Technology Data Exchange (ETDEWEB)

    Simimol, A. [Nanomaterials Research Lab, Surface Engineering Division, CSIR-National Aerospace Laboratories, Post Bag No. 1779, Bangalore 560017 (India); Department of Physics, National Institute of Technology Calicut, Calicut 673601 (India); Anappara, Aji A. [Department of Physics, National Institute of Technology Calicut, Calicut 673601 (India); Greulich-Weber, S. [Department of Physics, Nanophotonic Materials, Faculty of Science, University of Paderborn, 33095 Paderborn (Germany); Chowdhury, Prasanta [Nanomaterials Research Lab, Surface Engineering Division, CSIR-National Aerospace Laboratories, Post Bag No. 1779, Bangalore 560017 (India); Barshilia, Harish C., E-mail: harish@nal.res.in

    2015-06-07

    defect density by precisely controlling the dopant concentration in order to get the desired magnetic behavior at room temperature.

  7. Controllable synthesis of Co{sub 3}O{sub 4}/polyethyleneimine-carbon nanotubes nanocomposites for CO and NH{sub 3} gas sensing at room temperature

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Yufei [Key Laboratory of Functional Inorganic Material Chemistry, Ministry of Education, School of Chemistry and Materials Science, Heilongjiang University, Harbin 150080 (China); Kan, Kan [Key Laboratory of Functional Inorganic Material Chemistry, Ministry of Education, School of Chemistry and Materials Science, Heilongjiang University, Harbin 150080 (China); Institute of Advanced Technology, Heilongjiang Academy of Sciences, Harbin 150000 (China); Song, Wanzhen; Zhang, Guo; Dang, Lifang [Key Laboratory of Functional Inorganic Material Chemistry, Ministry of Education, School of Chemistry and Materials Science, Heilongjiang University, Harbin 150080 (China); Xie, Yu [Department of Materials Chemistry, Nanchang Hangkong University, Nanchang 330063 (China); Shen, Peikang [Department of Physics and Engineering, Sun Yat-sen University, Guangzhou 510275 (China); Li, Li, E-mail: llwjjhlju@sina.cn [Key Laboratory of Functional Inorganic Material Chemistry, Ministry of Education, School of Chemistry and Materials Science, Heilongjiang University, Harbin 150080 (China); Key Laboratory of Chemical Engineering Process & Technology for High-efficiency Conversion, School of Chemistry and Materials Science, Heilongjiang University, Harbin 150080 (China); Shi, Keying, E-mail: shikeying2008@163.com [Key Laboratory of Functional Inorganic Material Chemistry, Ministry of Education, School of Chemistry and Materials Science, Heilongjiang University, Harbin 150080 (China)

    2015-08-05

    Graphical abstract: Co{sub 3}O{sub 4}/polyethyleneimine-carbon nanotubes composites (CoPCNTs) have been successfully controllable synthesized via hydrothermal method at different temperature. The CoPCNTs sensors exhibited the highest response to CO and NH{sub 3} gases with response time of 4 s and 4.3 s, low detection limit of 5 ppm and 1 ppm at room temperature, respectively. The enhanced gas sensing could be ascribed to the synergistic effect between the tiny size of Co{sub 3}O{sub 4} and good conductivity of carbon nanotubes functionalized by polyethyleneimine. - Highlights: • The CNTs functionalized by polyethyleneimine provided a new functional structural. • The novel 1D structure could capture and migrate electrons quickly. • The Co{sub 3}O{sub 4} nanoparticles liked a snake winding around CNTs. • The gas sensor could work at room temperatures, which suit to practical application. - Abstract: A novel 1D Co{sub 3}O{sub 4}/polyethyleneimine-carbon nanotubes composites (CoPCNTs) have been successfully synthesized via hydrothermal method at different temperature. The CNTs functionalized by polyethyleneimine (PCNTs) provided a new material with new structural and functional properties. The PCNTs was used as loading guider and electron transfer path. The Co{sub 3}O{sub 4} nanoparticles (NPs) loaded on the PCNTs surface liked a snake winding around CNTs, and the size was about 5–10 nm. The gas sensing characteristics of the CoPCNTs sensors to carbon monoxide (CO) and ammonia (NH{sub 3}) were evaluated with different gas concentration. The CoPCNTs sensors grown at 160 °C exhibited the highest response to CO and NH{sub 3} gases with response time of 4 s and 4.3 s at room temperature (RT), respectively. Hence, the approach developed in this work would be important for the low-cost and large-scale production of the CoPCNTs materials with highly promising applications in gas sensors.

  8. Design of Air Conditioning System and Automatic Control for Vaccine Hatch Room%疫苗孵房空调系统及自控设计

    Institute of Scientific and Technical Information of China (English)

    朱晔

    2015-01-01

    孵房是疫苗生产过程中重要的场所,其对环境的要求比较高。为生产水痘减毒活疫苗,根据该疫苗的生产条件要求,设计了一套空调系统及控制流程。该系统的运行特性表明,该系统的温度控制在(37±0.5)℃,湿度控制在45%~65%。孵房的净化级别可以达到C级,符合该疫苗的生产条件要求。%Hatch room is the important space for vaccine production, and demands a high quality of environment. In the present study, an air conditioning system and the automatic control process for the production of varicella attenuated live vaccine was designed based on requirement of the production conditions. The operation performance of this system shows that, the temperature is controlled within (37±0.5)oC and the humidity is controlled within 45%~65%. The purity of air can reach up to level C, which is in accordance with the requirement of production conditions.

  9. Effcacy of different biological control agents against major postharvest pathogens of grapes under room temperature storage conditions

    Directory of Open Access Journals (Sweden)

    Ramu SENTHIL

    2011-05-01

    Full Text Available Normal 0 14 false false false IT ZH-TW X-NONE MicrosoftInternetExplorer4 Grapes were treated post harvest with a variety of biological agents to determine their effcacy in reducing yield loss. The agents Pseudomonas, Bacillus, Trichoderma and yeast isolates were individually screened against a number of postharvest pathogens including Aspergillus carbonarius, Penicillum expansum, and Fusarium moniliforme. B. subtilis strains EPC-8 and EPCO-16 showed high mycelial growth suppression of A. carbonarius and P. expansum  in vitro. The fungal antagonist Trichoderma viride strain (Tv Tvm was the most effective, inhibiting mycelial growth by 88.8 per cent. The biological control agents were tested in pre, post and combined inoculation studies against postharvest pathogens of grapes.  In the pre inoculation, B. subtilis (EPC-8 reduced the disease incidence of A. carbonarius causing rot, T. harzianum (Th Co was effective against P. expansum, and T. viride (Tv Tvm was effective against F. moniliforme. The same trend of effectiveness was also found in the post-inoculation and combined inoculation tests.

  10. Investigation of the Contamination Control in a Cleaning Room with a Moving AGV by 3D Large-Scale Simulation

    Directory of Open Access Journals (Sweden)

    Qing-He Yao

    2013-01-01

    Full Text Available The motions of the airflow induced by the movement of an automatic guided vehicle (AGV in a cleanroom are numerically studied by large-scale simulation. For this purpose, numerical experiments scheme based on domain decomposition method is designed. Compared with the related past research, the high Reynolds number is treated by large-scale computation in this work. A domain decomposition Lagrange-Galerkin method is employed to approximate the Navier-Stokes equations and the convection diffusion equation; the stiffness matrix is symmetric and an incomplete balancing preconditioned conjugate gradient (PCG method is employed to solve the linear algebra system iteratively. The end wall effects are readily viewed, and the necessity of the extension to 3 dimensions is confirmed. The effect of the high efficiency particular air (HEPA filter on contamination control is studied and the proper setting of the speed of the clean air flow is also investigated. More details of the recirculation zones are revealed by the 3D large-scale simulation.

  11. Touchless control module for diagnostic images at the surgery room using the Leap Motion system and 3D Slicer Software

    Directory of Open Access Journals (Sweden)

    Andrés Felipe Botero-Ospina

    2017-01-01

    Full Text Available Durante los procedimientos quirúrgicos es importante que el personal (cirujanos, residentes o asistentes interactúe con el paciente, evitando cualquier contacto físico con equipo y materiales que pudieron no ser esterilizados apropiadamente. Esto se hace con el fin de evitar al paciente infecciones y complicaciones posteriores a la cirugía. Con el aumento de la disponibilidad de imágenes diagnósticas esta herramienta se ha hecho cada vez más indispensable en los quirófanos, pero no siempre es posible mantener el control de asepsia de los equipos informáticos en los cuales se ejecutan los programas de visualización, factor que dificulta el acceso al personal asistencial a la información contenida en las imágenes. En este trabajo se presenta el desarrollo de un sistema que permite manipular un programa de visualización de imágenes diagnósticas mediante gestos evitando que el cirujano tenga contacto directo con la computadora. El sistema, que requiere una computadora con el software 3D-Slicer y el dispositivo Leap Motion, permite mediante gestos realizados con las manos acceder a operaciones básicas como el movimiento entre cortes de un volumen, cambio del tamaño de la imagen y cambio del plano anatómico de visualización, operaciones que para el cirujano son esenciales para la ubicación espacial y la toma de decisiones.

  12. Montreal Modern

    DEFF Research Database (Denmark)

    Handberg, Kristian

    2015-01-01

    Through analyses of the retro scenes in Montreal, Canada, the article discusses retro culture’s role as cultural memory. It is shown how Montreal’s cultural identity is formed by memories of modern culture such as the Red-light and Sin City reputation of the illicit nightlife of the 1940s and 1950s...

  13. Modern Spectroscopy

    Science.gov (United States)

    Barrow, Gordon M.

    1970-01-01

    Presents the basic ideas of modern spectroscopy. Both the angular momenta and wave-nature approaches to the determination of energy level patterns for atomic and molecular systems are discussed. The interpretation of spectra, based on atomic and molecular models, is considered. (LC)

  14. Italian Modernities

    DEFF Research Database (Denmark)

    Thomassen, Bjørn; Forlenza, Rosario

    assumptions that have substituted for thought and that have perpetuated prejudices both within and outside Italy’s borders. Grounded in meticulous historical and ethnological research, Italian Modernities deserves as wide an audience as its scholarship is deep.” (Michael Herzfeld, Ernest E. Monrad Professor...

  15. 大攻角导弹控制的经典和现代方法比较%Comparisons on Classic and Modern Controls for High AOA Missiles

    Institute of Scientific and Technical Information of China (English)

    宋雪海; 侯明善; 熊飞

    2011-01-01

    Comparisons on precision and robustness of classic and modern controls for high Angle-of-Attack (AOA) are presented. Based on the nonlinear characteristics of the high AOA missile, two kinds of missile longitudinal autopilot are designed using classical three-loops configuration and dynamic inversion embedded pole placement technique respectively. Study on their command tracking precision and robustness have been conducted. It's proved by simulation that classic and modern controls are nearly identical in either rapidity of response or robustness, but modern control can obtain better tracking precision.%比较研究了大攻角导弹的经典和现代控制方法的精度和鲁棒性.基于大攻角非线性弹体动力学模型,根据经典三回路控制系统结构和动态逆双时标极点配置方法分别设计了控制器,研究了两种控制方法的指令跟踪精度和抗弹体气动参数摄动的鲁棒性.结果表明,传统控制方法的鲁棒性和快速性与现代方法基本一致,而现代方法则具有更好的稳态精度.

  16. Locker Room Design Trends.

    Science.gov (United States)

    Wiens, Janet

    2001-01-01

    Examines how today's college and university athletic locker rooms have become sophisticated recruiting tools that rival many professional facilities. Locker room design and location and their level of furniture, finishes, and equipment are discussed as is the trend for more environmentally friendly locker rooms. (GR)

  17. Locker Room Design Trends.

    Science.gov (United States)

    Wiens, Janet

    2001-01-01

    Examines how today's college and university athletic locker rooms have become sophisticated recruiting tools that rival many professional facilities. Locker room design and location and their level of furniture, finishes, and equipment are discussed as is the trend for more environmentally friendly locker rooms. (GR)

  18. Linkage of spreaders an the LWL infrastructure of the control room Garzweiler II in the open-cast mining Garzweiler; Anbindung der Absetzer an die LWL-Infrastruktur des Leitstandes Garzweiler II im Tagebau Garzweiler

    Energy Technology Data Exchange (ETDEWEB)

    Dueren, Daniel [RWE Power Aktiengesellschaft, Grevenbroich (DE). Tagebau Garzweiler, Infrastruktur Elektrotechnik - Technische Unterstuetzung (PCG-IE-T)

    2011-12-15

    In the Rhenish mining area nearly 100 million tons of brown coal were produced annually. The conveyors are connected with each other and with the central process control system. The control of the plant is performed by a control room. In light of the retrofitting of the band control center for the open-cast mining Garzweiler a broadband communication network based on OTN (Open Transport Network) was established. The connection of the spreader to the infrastructure of the control room via OTN nodes was performed in the years 2006 to 2010. Six spreaders as well as the associated belt grinding carriages can be connected to the central control of the band control station.

  19. Simulation and experimental studies of operators` decision styles and crew composition while using an ecological and traditional user interface for the control room of a nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Meshkati, N.; Buller, B.J.; Azadeh, M.A. [Univ. of Southern California, Los Angeles, CA (United States)

    1995-04-01

    The goal of this research is threefold: (1) use of the Skill-, Rule-, and Knowledge-based levels of cognitive control -- the SRK framework -- to develop an integrated information processing conceptual framework (for integration of workstation, job, and team design); (2) to evaluate the user interface component of this framework -- the Ecological display; and (3) to analyze the effect of operators` individual information processing behavior and decision styles on handling plant disturbances plus their performance on, and preference for, Traditional and Ecological user interfaces. A series of studies were conducted. In Part I, a computer simulation model and a mathematical model were developed. In Part II, an experiment was designed and conducted at the EBR-II plant of the Argonne National Laboratory-West in Idaho Falls, Idaho. It is concluded that: the integrated SRK-based information processing model for control room operations is superior to the conventional rule-based model; operators` individual decision styles and the combination of their styles play a significant role in effective handling of nuclear power plant disturbances; use of the Ecological interface results in significantly more accurate event diagnosis and recall of various plant parameters, faster response to plant transients, and higher ratings of subject preference; and operators` decision styles affect on both their performance and preference for the Ecological interface.

  20. Antiseptic Effect of Conventional Povidone-Iodine Scrub, Chlorhexidine Scrub, and Waterless Hand Rub in a Surgical Room: A Randomized Controlled Trial.

    Science.gov (United States)

    Tsai, Jui-Chen; Lin, Yen-Kuang; Huang, Yen-Jung; Loh, El-Wui; Wen, Hsiao-Yun; Wang, Chia-Hui; Tsai, Yin-Tai; Hsieh, Wen-Shyang; Tam, Ka-Wai

    2017-04-01

    OBJECTIVE Effective perioperative hand antisepsis is crucial for the safety of patients and medical staff in surgical rooms. The antimicrobial effectiveness of different antiseptic methods, including conventional hand scrubs and waterless hand rubs, has not been well evaluated. DESIGN, SETTING, AND PARTICIPANTS A randomized controlled trial was conducted to investigate the effectiveness of the 3 antiseptic methods among surgical staff of Taipei Medical University-Shuang Ho Hospital. For each method used, a group of 80 participants was enrolled. INTERVENTION Surgical hand cleansing with conventional 10% povidone-iodine scrub, conventional 4% chlorhexidine scrub, or waterless hand rub (1% chlorhexidine gluconate and 61% ethyl alcohol). RESULTS Colony-forming unit (CFU) counts were collected using the hand imprinting method before and after disinfection and after surgery. After surgical hand disinfection, the mean CFU counts of the conventional chlorhexidine (0.5±0.2, Pscrub and waterless hand rub were superior to a conventional povidone-iodine product in bacterial inhibition. We recommend using conventional chlorhexidine scrub as a standard method for perioperative hand antisepsis. Waterless hand rub may be used if the higher cost is affordable. Infect Control Hosp Epidemiol 2017;38:417-422.

  1. Effects of postexercise ice-water and room-temperature water immersion on the sensory organization of balance control and lower limb proprioception in amateur rugby players

    Science.gov (United States)

    Chow, Gary C.C.; Yam, Timothy T.T.; Chung, Joanne W.Y.; Fong, Shirley S.M.

    2017-01-01

    Abstract Background: This single-blinded, three-armed randomized controlled trial aimed to compare the effects of postexercise ice-water immersion (IWI), room-temperature water immersion (RWI), and no water immersion on the balance performance and knee joint proprioception of amateur rugby players. Methods: Fifty-three eligible amateur rugby players (mean age ± standard deviation: 21.6 ± 2.9 years) were randomly assigned to the IWI group (5.3 °C), RWI group (25.0 °C), or the no immersion control group. The participants in each group underwent the same fatigue protocol followed by their allocated recovery intervention, which lasted for 1 minute. Measurements were taken before and after the fatigue-recovery intervention. The primary outcomes were the sensory organization test (SOT) composite equilibrium score (ES) and the condition-specific ES, which were measured using a computerized dynamic posturography machine. The secondary outcome was the knee joint repositioning error. Two-way repeated measures analysis of variance was used to test the effect of water immersion on each outcome variable. Results: There were no significant within- and between-group differences in the SOT composite ESs or the condition-specific ESs. However, there was a group-by-time interaction effect on the knee joint repositioning error. It seems that participants in the RWI group had lower errors over time, but those in the IWI and control groups had increased errors over time. The RWI group had significantly lower error score than the IWI group at postintervention. Conclusion: One minute of postexercise IWI or RWI did not impair rugby players’ sensory organization of balance control. RWI had a less detrimental effect on knee joint proprioception to IWI at postintervention. PMID:28207546

  2. Control system and environmental parameters monitoring of the Tandetron Accelerator clean room; Sistema de control y monitoreo de parametros ambientales del cuarto limpio del acelerador Tandetron

    Energy Technology Data Exchange (ETDEWEB)

    Mejia V, M.E.; Garcia H, J.M.; Flores M, J. [ININ, Departamento de Sistemas Electronicos, 52750 La Marquesa, Estado de Mexico (Mexico)]. e-mail: mmejia@nuclear.inin.mx

    2007-07-01

    A control system and monitoring of humidity and temperature implemented by means of a system based on a microcontroller, an intelligent sensor and a stage of power for the actuators handling is described. The change of the levels of reference of the control system and the monitoring of the physical controlled variables can be carried out from any connected computer to a local net or Internet. (Author)

  3. Emissions of PCDD/Fs, PCBs, and PAHs from a modern diesel engine equipped with catalyzed emission control systems.

    Science.gov (United States)

    Laroo, Christopher A; Schenk, Charles R; Sanchez, L James; McDonald, Joseph

    2011-08-01

    Exhaust emissions of 17 2,3,7,8-substituted chlorinated dibenzo-p-dioxin/furan (CDD/F) congeners, tetra-octa CDD/F homologues, 12 2005 WHO chlorinated biphenyls (CB) congeners, mono-nona CB homologues, and 19 polycyclic aromatic hydrocarbons (PAHs) from a model year 2008 Cummins ISB engine were investigated. Testing included configurations composed of different combinations of aftertreatment including a diesel oxidation catalyst (DOC), catalyzed diesel particulate filter (CDPF), copper zeolite urea selective catalytic reduction (SCR), iron zeolite SCR, and ammonia slip catalyst. Results were compared to a baseline engine out configuration. Testing included the use of fuel that contained the maximum expected chlorine (Cl) concentration of U.S. highway diesel fuel and a Cl level 1.5 orders of magnitude above. Results indicate there is no risk for an increase in polychlorinated dibenzo-p-dioxin/furan and polychlorinated biphenyl emissions from modern diesel engines with catalyzed aftertreatment when compared to engine out emissions for configurations tested in this program. These results, along with PAH results, compare well with similar results from modern diesel engines in the literature. The results further indicate that polychlorinated dibenzo-p-dioxin/furan emissions from modern diesel engines both with and without aftertreatment are below historical values reported in the literature as well as the current inventory value.

  4. Study of factors controlling exposure dose and image quality of C-arm in operation room according to detector size of it (Mainly L-Spine AP study)

    Energy Technology Data Exchange (ETDEWEB)

    Chui, Sung Hyun; Jo, Hwang Woo [Dept. of Radiology, Kyung Hee University Hospital at Gangdong, Seoul (Korea, Republic of); Chun, Woon Kwan; Song, Ha Jin [Dept. of Nuclear Engineering, Chosun University, Gwangju (Korea, Republic of); Dong, Kyung Rae [Dept. of Radiological Technology, Gwangju Health University, Gwangju (Korea, Republic of); Choi, Eun Jin [Dept. of Public Health and Medicine, Dongshin University, Naju (Korea, Republic of)

    2015-02-15

    Time of operation has been reduced and accuracy of operation has been improved since C-arm, which offer real-time image of patient, was introduced in operation room. However, because of the contamination of patient, C-arm could not be used more appropriately. Therefore, this study is to know factors of controlling exposure dose, image quality and the exposed dose of health professional in operation room. Height of Wilson frame (bed for operation) was fixed at 130 cm. Then, Model 76-2 Phantom, which was set by assembling manual of Fluke Company, was set on the bed. Head/Spine Fluoroscopy AEC mode was set for exposure condition. According to detector size of C-arm, the absorbed dose per min was measured in the 7 steps OFD (cm) from 10 cm to 40 cm (10, 15, 20, 25, 30, 35, 40 cm). In each step of OFD, the absorbed dose per min of same diameter of collimation was measured. Moreover, using Nero MAX Model 8000, exposure dose per min was measured according to 3 step of distance from detector (20 cm, 60 cm, 100 cm). Finally, resolution was measured by CDRH Disc Phantom and magnification of each OFD was measured by aluminum stick bar. According to detector size of C-arm, difference of absorbed dose shows that the dose of 20 cm OFD is 1.750 times higher than the dose of 40 cm OFD. It means that the C-arm, which has smaller size of detector, shows the bigger difference of absorbed dose per min (p<0.05). In the difference of absorbed dose in the same step of OFD (from 20 cm to 40 cm), the absorbed dose of 9 inch detect or C-arm was 1.370 times higher than 12 inch' s (p<0.05). When OFD was set to 20 cm OFD, the absorbed dose of non-collimation case was approximately 0.816 times lower than the absorbed dose of collimation cases (p<0.05). When the distance was 20 cm from detector, exposed does includes first-ray and scatter-ray. When the distance was 60 cm and 100 cm from detector, exposed does includes just scatter-ray. So, there was the 2.200 times difference of absorbed

  5. Modern maths

    CERN Document Server

    Thom,R

    1974-01-01

    Le Prof. R. Thom expose ses vues sur l'enseignement des mathématiques modernes et des mathémathiques de toujours. Il est un grand mathématicien et était professeur à Strasbourg; maintenant il est professeur de hautes études scientifiques et était invité par le Prof. Piaget à Genève

  6. 远程控制技术在现代化制造实验中的应用%Application of Remote Control in Modern Manufacturing Experiment

    Institute of Scientific and Technical Information of China (English)

    刘友和; 马德; 朱锦标; 刘惠文

    2001-01-01

    介绍一种基于视像会议技术和虚拟网络计算技术的远程控制技术在现代化制造实验中的应用。在应用中加强粤港高校合作,进行现代化的创新设计与制造实验,可收到较好的效果。%Based on video conference technique and virtual network computer,this paper introduced the application of remote control technology in modern manufacturing experiments. Better result can be achieved by enhancing the cooperation of universities both in Hong Kong and in Guangzhou to put up the innovative project and modern manufacturing experiments.

  7. Cyberspace modernization :

    Energy Technology Data Exchange (ETDEWEB)

    Keliiaa, Curtis M.; McLane, Victor N.

    2014-07-01

    A common challenge across the communications and information technology (IT) sectors is Internet + modernization + complexity + risk + cost. Cyberspace modernization and cyber security risks, issues, and concerns impact service providers, their customers, and the industry at large. Public and private sectors are struggling to solve the problem. New service opportunities lie in mobile voice, video, and data, and machine-to-machine (M2M) information and communication technologies that are migrating not only to predominant Internet Protocol (IP) communications, but also concurrently integrating IP, version 4 (IPv4) and IP, version 6 (IPv6). With reference to the Second Internet and the Internet of Things, next generation information services portend business survivability in the changing global market. The planning, architecture, and design information herein is intended to increase infrastructure preparedness, security, interoperability, resilience, and trust in the midst of such unprecedented change and opportunity. This document is a product of Sandia National Laboratories Tribal Cyber and IPv6 project work. It is a Cyberspace Modernization objective advisory in support of bridging the digital divide through strategic partnership and an informed path forward.

  8. Automated Air Traffic Control Operations with Weather and Time-Constraints: A First Look at (Simulated) Far-Term Control Room Operations

    Science.gov (United States)

    Prevot, Thomas; Homola, Jeffrey R.; Martin, Lynne H.; Mercer, Joey S.; Cabrall, Christopher C.

    2011-01-01

    In this paper we discuss results from a recent high fidelity simulation of air traffic control operations with automated separation assurance in the presence of weather and time-constraints. We report findings from a human-in-the-loop study conducted in the Airspace Operations Laboratory (AOL) at the NASA Ames Research Center. During four afternoons in early 2010, fifteen active and recently retired air traffic controllers and supervisors controlled high levels of traffic in a highly automated environment during three-hour long scenarios, For each scenario, twelve air traffic controllers operated eight sector positions in two air traffic control areas and were supervised by three front line managers, Controllers worked one-hour shifts, were relieved by other controllers, took a 3D-minute break, and worked another one-hour shift. On average, twice today's traffic density was simulated with more than 2200 aircraft per traffic scenario. The scenarios were designed to create peaks and valleys in traffic density, growing and decaying convective weather areas, and expose controllers to heavy and light metering conditions. This design enabled an initial look at a broad spectrum of workload, challenge, boredom, and fatigue in an otherwise uncharted territory of future operations. In this paper we report human/system integration aspects, safety and efficiency results as well as airspace throughput, workload, and operational acceptability. We conclude that, with further refinements. air traffic control operations with ground-based automated separation assurance can be an effective and acceptable means to routinely provide very high traffic throughput in the en route airspace.

  9. A Development Method of Mobile Computerized Procedure System for the Cooperation among Field Workers and Main Control Room Operators in Korean Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sun Jin; Seong, No Kyu; Jung, Yeon Sub [KHNP ,Daejeon (Korea, Republic of)

    2014-08-15

    Human errors can occur during the test and maintenance of steam generator, safety injection system and other various systems and devices in nuclear power plants (NPPs). Most of human errors can be improved by the human error prevention techniques such as self-check, peer-check, concurrent verification and etc. Another important technique is to share work information among main control room (MCR) operators and field workers. Various field service automation tools have been developed with recent information technology in many countries. APR1400 computerized procedure system (CPS) has been developed for the MCR operators of Shin-Kori 3 and 4 units. Especially, the concurrent verification support design is applied in the construction project of Shin-Hanul 1 and 2 CPS. It is expected that the proposed mobile CPS can enhance the reduction of human errors by supporting human error prevention techniques and information sharing. This paper describes the technical issues of the mobile CPS (mobile CPS) in the initial development stage. Based on the design of APR1400, CRI CPS has been developed and operated for SKN 3 and 4 HFE V and V and license test for the MCR operating staff. Therefore the mobile CPS will be developed by upgrading the CRI CPS with improved features.

  10. 9 July 2008 - Microsoft Co-Founder P. Allen visiting ATLAS control room and underground experimental area with Adviser J. Ellis and IT Department Head W. von Rüden.

    CERN Multimedia

    Maximilien Brice

    2008-01-01

    9 July 2008 - Microsoft Co-Founder P. Allen visiting ATLAS control room and underground experimental area with Adviser J. Ellis and IT Department Head W. von Rüden and guided by ATLAS Collaboration Users S. Goldfarb, P. Nevski and L. Price.

  11. On Risk Control and Risk of Modern Technologies%论风险控制与现代技术风险

    Institute of Scientific and Technical Information of China (English)

    欧庭高; 何发钦

    2015-01-01

    现代技术风险日益为社会所关注,成为管理学、社会学和哲学等众多学科的研究主题,它的产生和发展源于人们对风险的控制逻辑。风险控制包含一套成功的经验技能、技艺和实用性的知识。这套成功经验和知识的演变,带来了技术的创造和发明。技术创造和发明把风险管控推上新的台阶和层次,与此同时又产生技术风险。风险控制与技术对风险控制辩证的建构,形成一个悖论式的自反生长结构,催生现代技术风险,造成风险丛生的现代社会。%The risk of modern technologies is concerned increasingly with in society and has become a key research top-ic of management science,sociology,philosophy and other subjects.Its source and development results from our con-trol logic on risk.Risk control contains a set of successful skills,techniques and practical knowledge,whose evolution has boosted the creation and invention in technology.The creation and invention in technology promotes risk manage-ment to higher step and hierarchy and at the same time brings about technological risk.The dialectical construction of risk control and risk control from technology forms paradoxically a reflexive growth structure,producing modern technology risk as well as causing a modern society with rich risk.

  12. Advanced control room design review guidelines: Integration of the NUREG-0700 guidelines and development of new human-system interface guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Carter, R.J.

    1997-07-01

    This report documents the work conducted in four tasks of the Nuclear Regulatory Commission (NRC) project entitled Review Criteria for Human Factors Aspects of Advanced Controls and Instrumentation. The purpose of the first task was to integrate the applicable sections of NUREG-0700 into the advanced control room design review (ACRDR) guidelines to ensure that all applicable guidelines are together in one document and conveniently accessible to users. The primary objective of the second task was to formulate a strategy for the development of new ACRDR guidelines that have not otherwise been identified. The main focus of the third task was to modify the individual ACRDR guidelines generated to date to ensure that they are suitable for the intended nuclear power plant (NPP) control station system application. The goal of the fourth task was to develop human factors guidelines for two human-system interface categories that are missing from the current ACRDR guidelines document. During the first task those areas in NUREG-0700 that are not addressed by the ACRDR guidelines document were identified, the areas were subsequently reviewed against six recent industry human factors engineering review guidelines, and the NUREG-0700 guidelines were updated as necessary. In the second task 13 general categories of human-system interface guidelines that are either missing from or not adequately addressed by the ACRDR document were discovered. An approach was derived for the development of new ACRDR guidelines, a preliminary assessment of the available sources that may be useful in the creation of new guidelines and their applicability to the identified human-system interface categories was performed, and an estimate was made of the amount of time and level of effort required to complete the development of needed new ACRDR guidelines. During the third task those NPP control station systems to which the NUREG-0700 and ACRDR guidelines apply were identified, matrices of such

  13. Angiotensin converting enzyme DD genotype is associated with acute coronary syndrome severity and sudden cardiac death in Taiwan: a case-control emergency room study

    Directory of Open Access Journals (Sweden)

    Chen Ying-Hsin

    2012-02-01

    Full Text Available Abstract Background Angiotensin converting enzyme (ACE gene insertion/deletion (I/D polymorphisms have been associated with acute coronary syndrome (ACS; however, several controversial results have also been found in different studied populations. This hospital-based, emergency room, case-control study in Taiwan retrospectively investigated 111 ACS patients, and 195 non-coronary subjects as a control group, to study the effects of ACE I/D polymorphism in the most urgent ACS patients. ACE I/D polymorphisms were determined by polymerase chain reaction-based assays and their associations with ACS risk, severity, and sudden cardiac death were determined. Results The ACE DD genotype was associated with ACS incidence. The DD genotype was associated with a significant 4-fold higher risk of ACS in multivariate analysis (odds ratio (OR = 4.295; 95% confidence interval (CI: 1.436-12.851, p = 0.009, and a 3.35-fold higher risk of acute myocardial infarction. DD genotype carriers also had more than 3-fold higher risks of stenosis in all the three coronary arteries, left anterior descending artery infarction, and anterior wall infarction. In addition, the DD genotype was also associated with a higher risk of sudden cardiac death (OR = 6.484, 95% CI: 1.036-40.598, p = 0.046. Conclusions This study demonstrated that the ACE DD genotype is an independent risk factor for ACS, and in particular, for acute myocardial infarction. In addition, the ACE DD genotype is also associated with greater ACS severity and a higher risk of sudden cardiac death. ACE genotyping is recommended for patients with a history of ACS, and more intensive preventive care is suggested for patients with the DD genotype.

  14. Modern plasmonics

    CERN Document Server

    Maradudin, Alexei A; Barnes, William L

    2014-01-01

    Plasmonics is entering the curriculum of many universities, either as a stand alone subject, or as part of some course or courses. Nanotechnology institutes have been, and are being, established in universities, in which plasmonics is a significant topic of research. Modern Plasmonics book offers a comprehensive presentation of the properties of surface plasmon polaritons, in systems of different structures and various natures, e.g. active, nonlinear, graded, theoretical/computational and experimental techniques for studying them, and their use in a variety of applications. Contains materia

  15. Health Physics counting room

    CERN Multimedia

    1970-01-01

    The Health Physics counting room, where the quantity of induced radioactivity in materials is determined. This information is used to evaluate possible radiation hazards from the material investigated.

  16. LoRA: A Loudspeaker-Based Room Auralization System

    DEFF Research Database (Denmark)

    Favrot, Sylvain Emmanuel; Buchholz, Jörg

    2010-01-01

    In order to study basic human perception in reverberant environments, a novel loudspeaker-based room auralization (LoRA) system is proposed in this paper. The LoRA system efficiently combines modern room acoustic models with high-order Ambisonic auralization. An objective evaluation has been...... carried out demonstrating the applicability of the LoRA system. Room acoustic parameters (reverberation time, clarity, speech transmission index and inter-aural cross correlation coefficients) of room impulse responses were compared at the input and the simulated output of the LoRA system. Results show...

  17. Dynamics of Control and Resistance: Reactions to the Modern Policy of Assimilation of the Travellers in Norway

    Directory of Open Access Journals (Sweden)

    Rune Halvorsen

    2004-07-01

    Full Text Available For much of the 20th century, the Norwegian authorities pursued a strict assimilation policy towards Travellers (tatere/ romanifolket and their culture. As was the case in many other countries, Travellers were constructed as "the other" (Riggins 1997, MacLaughlin 1999. When compared to other Western European countries, it is, however, surprising that Norwegian Travellers were seen as such a serious problem and threat during the 20th century. The 1845 census counted 1145 Travellers out of a total population of 1.3 million in Norway (Sundt 1852, SSB 1968: Table 13. A private charity organisation acting on behalf of the state registered 5129 "itinerants" in their archives from 1900 to 1959 (Haave 2000. These were the figures that worried the elites. This paper examines the modern assimilation policy and Travellers' reactions to this policy. In particular the paper analyses the internal relation between the modern assimilation policy and the emergence of collective demands for recognition as an ethnic minority and moral redress among Travellers in the 1990s.

  18. International Atomic Energy Agency specialists meeting on experience in ageing, maintenance, and modernization of instrumentation and control systems for improving nuclear power plant availability

    Energy Technology Data Exchange (ETDEWEB)

    1993-10-01

    This report presents the proceedings of the Specialist`s Meeting on Experience in Aging, Maintenance and Modernization of Instrumentation and Control Systems for Improving Nuclear Power Plant Availability that was held at the Ramada Inn in Rockville, Maryland on May 5--7, 1993. The Meeting was presented in cooperation with the Electric Power Research Institute, Oak Ridge National Laboratory and the International Atomic Energy Agency. There were approximately 65 participants from 13 countries at the Meeting. Individual reports have been cataloged separately.

  19. Operating room of the future.

    Science.gov (United States)

    Bharathan, Rasiah; Aggarwal, Rajesh; Darzi, Ara

    2013-06-01

    Development of surgical care in the 21st century is increasingly dependent on demonstrating safety, efficacy and cost effectiveness. Over the past 2 decades, the potential role of simulation in surgery has been explored with encouraging results; this can now be linked to direct improvement in the quality of care provision. Computer-assisted surgical platforms, such as robotic surgery, offer us the versatility to embrace a host of technical and technological developments. Rapid development in nanomedicine will expand the limits of operative performance through improved navigation and surgical precision. Integration of the multiple functions of the future operating room will be essential in optimising resource management. The key to bringing about the necessary paradigm shift in the design and delivery of modern surgical care is to appreciate that we now function in an information age, where the integrity of processes is driven by apt data management.

  20. Visualizing the characteristics of a work process being observed from the main control room of nuclear power plants - identifying underlying requirements

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jinkyun; Jung, Wondea [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    One of the disseminated approaches is to identify and manage vulnerable tasks (i.e., error-prone tasks) by applying many kinds of human reliability assessment (HRA) techniques. That is, if HRA practitioners are able to identify plausible error forcing factors (e.g., performance shaping factors; PSFs) under a given task context, effective countermeasures that are helpful for reducing the possibility of human error can be drawn by deducing how to eliminate the associated PSFs. In order to reduce the variability of HRA results, the development of an objective criterion for determining the level of each PSF could be the most plausible countermeasure. In order to address this issue, this paper applied a process mining technique to the analysis of communication logs gathered from main control room (MCR) crews in NPPs, which could be useful for visualizing their characteristics in terms of the Work process. In this study, before providing additional information that is helpful for HRA practitioners in determining the quality of the Work process, three kinds of underlying requirements are identified. They are: (1) an ability to describe the flow of a work, (2) an ability to incorporate time and spatial information into the flow of a work, and (3) an ability to identify the flow of symptoms and/or knowledge being employed by an MCR crew. In order to satisfy these requirements, a couple of techniques can be used. This might allow partial pooling of log information according to how the information can be clustered.' In other words, the process mining technique is very useful for discovering the flow of a work being involved in a given situation, it is strongly expected that the analysis of communication logs that allow us to understand what and how they did in order to cope with a situation at hand. If so, it is possible to visualize necessary information that is essential for minimizing the variability of HRA practitioners who have to determine the quality of the Work

  1. Unlocking the Locker Room.

    Science.gov (United States)

    St. Clair, Dean

    1996-01-01

    Discusses locker-room design standards and common challenges when complying with the Americans with Disabilities Act. Accessibility and safety considerations for shower, toilet, and locker areas are addressed, as are entrance vestibules, drying and grooming areas, and private dressing rooms. (GR)

  2. Operating room manager game

    NARCIS (Netherlands)

    Hans, Erwin W.; Nieberg, Tim

    2007-01-01

    The operating room (OR) department of a hospital forms the heart of the organization, where the single largest cost is incurred. This document presents and reports on the “Operating Room Manager Game,” developed to give insight into managing a large hospital's OR department at various levels of cont

  3. Virtual Seminar Room

    DEFF Research Database (Denmark)

    Forchhammer, Søren Otto; Fosgerau, Anders; Hansen, Peter Søren Kirk

    1999-01-01

    The initial design considerations and research goals for an ATM network based virtual seminar room with 5 sites are presented.......The initial design considerations and research goals for an ATM network based virtual seminar room with 5 sites are presented....

  4. Our Urban Living Room

    DEFF Research Database (Denmark)

    Hjortshøj, Rasmus

    2016-01-01

    the boundaries between private and public space become fluid. Based on specific Cobe projects, Our Urban Living Room tells stories about the architectural development of Copenhagen, while exploring the progression of the Danish Capital - from an industrial city into an urban living room, known as one...

  5. Modern optics

    CERN Document Server

    Guenther, B D

    2015-01-01

    Modern Optics is a fundamental study of the principles of optics using a rigorous physical approach based on Maxwell's Equations. The treatment provides the mathematical foundations needed to understand a number of applications such as laser optics, fiber optics and medical imaging covered in an engineering curriculum as well as the traditional topics covered in a physics based course in optics. In addition to treating the fundamentals in optical science, the student is given an exposure to actual optics engineering problems such as paraxial matrix optics, aberrations with experimental examples, Fourier transform optics (Fresnel-Kirchhoff formulation), Gaussian waves, thin films, photonic crystals, surface plasmons, and fiber optics. Through its many pictures, figures, and diagrams, the text provides a good physical insight into the topics covered. The course content can be modified to reflect the interests of the instructor as well as the student, through the selection of optional material provided in append...

  6. Modern electrodynamics

    CERN Document Server

    Zangwill, Andrew

    2013-01-01

    An engaging writing style and a strong focus on the physics make this comprehensive, graduate-level textbook unique among existing classical electromagnetism textbooks. Charged particles in vacuum and the electrodynamics of continuous media are given equal attention in discussions of electrostatics, magnetostatics, quasistatics, conservation laws, wave propagation, radiation, scattering, special relativity and field theory. Extensive use of qualitative arguments similar to those used by working physicists makes Modern Electrodynamics a must-have for every student of this subject. In 24 chapters, the textbook covers many more topics than can be presented in a typical two-semester course, making it easy for instructors to tailor courses to their specific needs. Close to 120 worked examples and 80 applications boxes help the reader build physical intuition and develop technical skill. Nearly 600 end-of-chapter homework problems encourage students to engage actively with the material. A solutions manual is availa...

  7. Modern thermodynamics

    CERN Document Server

    Ben-Naim, Arieh

    2017-01-01

    This textbook introduces thermodynamics with a modern approach, starting from four fundamental physical facts (the atomic nature of matter, the indistinguishability of atoms and molecules of the same species, the uncertainty principle, and the existence of equilibrium states) and analyzing the behavior of complex systems with the tools of information theory, in particular with Shannon's measure of information (or SMI), which can be defined on any probability distribution. SMI is defined and its properties and time evolution are illustrated, and it is shown that the entropy is a particular type of SMI, i.e. the SMI related to the phase-space distribution for a macroscopic system at equilibrium. The connection to SMI allows the reader to understand what entropy is and why isolated systems follow the Second Law of Thermodynamics. The Second Llaw is also formulated for other systems, not thermally isolated and even open with respect to the transfer of particles. All the fundamental aspects of thermodynamics are d...

  8. An informationally structured room for robotic assistance.

    Science.gov (United States)

    Tsuji, Tokuo; Mozos, Oscar Martinez; Chae, Hyunuk; Pyo, Yoonseok; Kusaka, Kazuya; Hasegawa, Tsutomu; Morooka, Ken'ichi; Kurazume, Ryo

    2015-04-22

    The application of assistive technologies for elderly people is one of the most promising and interesting scenarios for intelligent technologies in the present and near future. Moreover, the improvement of the quality of life for the elderly is one of the first priorities in modern countries and societies. In this work, we present an informationally structured room that is aimed at supporting the daily life activities of elderly people. This room integrates different sensor modalities in a natural and non-invasive way inside the environment. The information gathered by the sensors is processed and sent to a centralized management system, which makes it available to a service robot assisting the people. One important restriction of our intelligent room is reducing as much as possible any interference with daily activities. Finally, this paper presents several experiments and situations using our intelligent environment in cooperation with our service robot.

  9. Influence of behavior control on occupational exposure of operating room nurses%行为控制对手术室护士职业暴露的影响

    Institute of Scientific and Technical Information of China (English)

    林华; 余丽君; 袁慧

    2015-01-01

    目的:探讨行为控制对手术室护士职业暴露的影响。方法:统计我院2009年7月~2013年6月施行行为控制前后66名手术室护士在35767例手术配合过程中发生的职业暴露次数,比较行为控制对手术室护士职业暴露的影响。结果:行为控制前护士的职业暴露率为0.18%,采取行为控制后职业暴露率为0.06%。结论:行为控制能有效降低职业暴露对手术室护士的伤害,可以作为预防和减少职业暴露的方法在临床使用。%Objective:To investigate the behavioral control of occupational exposure to operating room nurses.Statistical methods in our hospital in July 2009 to June 2013 after 66 behavioral control purposes operating room nurse in 35,767 cases occur during surgery with occupational exposure times,more behav-ioral control on the impact of occupational exposure to operating room nurses.Results:Behavioral control former nurse occupational exposure was 0.18%,af-ter taking behavior control occupational exposure was 0.06%.Conclusion:Behavioral control can effectively reduce occupational exposure to operating room nurse injuries,can be used as prevention and reduction of occupational exposure in clinical.

  10. 试论现代企业内部控制评价体系的建设%Discussion about construction of modern enterprise internal control evaluation system

    Institute of Scientific and Technical Information of China (English)

    罗想平

    2015-01-01

    Internal control is to manage the sound development trend of modern enterprise, the behavioral characteristics as"Control Self-Assessment."It is an enterprise in a given period, regular or irregular internal control system for self-evaluation, internal evaluation of the effectiveness and efficiency of control, so that it can better achieve the objectives of internal control. Basic features: focus on business process management and process control of production results; this kind of "control self-assessment" generally consists of business-related departments and personnel together.%企业内部控制是现代企业良性发展的管理趋势,其行为特征为“控制自我评估”,是指企业在一定时期内,定期或不定期对内部控制体系进行自我评价,评估内部控制的有效性及效率性,使之能更好地达到内部控制目标。基本特征为重点关注经营生产业务的过程和过程控制的效果;这样的“控制自我评估”一般由企业相关部门和人员共同完成。

  11. New Radiation Protection training room

    CERN Multimedia

    HSE Unit

    2013-01-01

    From now on, the theory and practical components of the Radiation Protection training, developed by the RP Group and offered by the HSE Unit’s Safety Training team to people working in a Controlled Radiation Area, will take place in a dedicated teaching room, designed specifically for this kind of training.   The new room is in the Safety Training Centre on the Prévessin site and has been open since 16 October. It has an adjoining workshop that, like the room itself, can accommodate up to 12 people. It is also equipped with an interactive board as well as instruments and detectors to test for ionising radiation. This room is located near the recently inaugurated LHC tunnel mock-up where practical training exercises can be carried out in conditions almost identical to those in the real tunnel. To consult the safety training catalogue and/or sign up for Radiation Protection training, please go to: https://cta.cern.ch For further information, please contact the Safety Trainin...

  12. Hydraulic conductivity of active layer soils in the McMurdo Dry Valleys, Antarctica: Geological legacy controls modern hillslope connectivity

    Science.gov (United States)

    Schmidt, Logan M.; Levy, Joseph S.

    2017-04-01

    Spatial variability in the hydraulic and physical properties of active layer soils influences shallow groundwater flow through cold-desert hydrological systems. This study measures the saturated hydraulic conductivity and grain-size distribution of 90 soil samples from the McMurdo Dry Valleys (MDV), Antarctica-primarily from Taylor Valley-to determine what processes affect the spatial distribution of saturated hydraulic conductivity in a simple, mineral-soil-dominated natural hillslope laboratory. We find that the saturated hydraulic conductivity and the grain-size distribution of soils are organized longitudinally within Taylor Valley. Soils sampled down-valley near the coast have a higher percentage of fine-sized sediments (fine sand, silt, clay) and lower saturated hydraulic conductivities than soils collected up-valley near Taylor Glacier (1.3 × 10- 2 vs. 1.2 × 10- 1 cm/s). Soils collected mid-valley have intermediate amounts of fines and saturated hydraulic conductivity values consistent with a hydrogeologic gradient spanning the valley from high inland to low near the coast. These results suggest the organization of modern soil properties within Taylor Valley is a relict signature from past glaciations that have deposited soils of decreasing age toward the mouth of the valley, modified by fluvial activity acting along temporal and microclimate gradients.

  13. Disinfection and sterilization monitoring and hospital infection control in operating room%手术室消毒灭菌监测与医院感染控制

    Institute of Scientific and Technical Information of China (English)

    唐香祝; 阮杏菲; 江翠波

    2016-01-01

    目的:探讨加强手术室消毒灭菌监测,对医院感染控制的作用。方法根据《消毒技术规范》中所规定的操作要求对手术室消毒灭菌效果进行监测。研究采用回顾性及现场临床观察方法,观察患者术后伤口情况。结果实施手术室消毒灭菌监测前,空气灭菌合格率、消毒物品灭菌合格率、医护人员手灭菌合格率分别为92.63%、93.75%、88.57%,实施手术室消毒灭菌监测后,空气灭菌合格率、消毒物品灭菌合格率、医护人员手灭菌合格率分别为98.96%、100.00%、100.00%,差异有统计学意义(P<0.05);实施手术室消毒灭菌监测前,手术患者切口感染率为6.41%,Ⅰ类切口感染率、Ⅱ类切口感染率、Ⅲ类切口感染率分别为2.54%、6.22%、11.34%,实施手术室消毒灭菌监测后,手术患者切口感染率为2.57%,Ⅰ类切口感染率、Ⅱ类切口感染率、Ⅲ类切口感染率分别为0.39%、2.21%、5.77%,差异有统计学意义(P<0.05)。结论通过手术室消毒灭菌监测,能够有效提高手术室内空气、设备、器械等灭菌率。此外,还能够有效降低手术患者术后切口感染率,值得推广。%Objective To study the effect of disinfection and sterilization monitoring and hospital infection control in operating room.MethodsTo monitor the effect of disinfection and sterilization in operating room according to the operation requirements stipulate by disinfection technical guidelines.To observe the patients' postoperative wound condition according to the methods of retrospectively study and spot clinical observation.Results The differences of the eligible sterilization rate of air, disinfection materials, hands of medical staff after implementation of disinfection and sterilization monitoring(98.96%,100.00%,100.00%)were statically significant compared with which before implementation of disinfection and sterilization monitoring(92

  14. The Virtual Dressing Room

    DEFF Research Database (Denmark)

    Holte, Michael Boelstoft; Gao, Yi; Petersson, Eva

    2015-01-01

    This paper presents the design and evaluation of a usability and user experience test of a virtual dressing room. First, we motivate and introduce our recent developed prototype of a virtual dressing room. Next, we present the research and test design grounded in related usability and user experi...... experience studies. We give a description of the experimental setup and the execution of the designed usability and user experience test. To this end, we report interesting results and discuss the results with respect to user-centered design and development of a virtual dressing room....

  15. Transformer room fire tests

    Science.gov (United States)

    Fustich, C. D.

    1980-03-01

    A series of transformer room fire tests are reported to demonstate the shock hazard present when automatic sprinklers operate over energized electrical equipment. Fire protection was provided by standard 0.5 inch pendent automatic sprinklers temperature rated at 135 F and installed to give approximately 150 sq ft per head coverage. A 480 v dry transformer was used in the room to provide a three phase, four wire distribution system. It is shown that the induced currents in the test room during the various tests are relatively small and pose no appreciable personnel shock hazard.

  16. Room Acoustical Fields

    CERN Document Server

    Mechel, Fridolin

    2013-01-01

    This book presents the theory of room acoustical fields and revises the Mirror Source Methods for practical computational use, emphasizing the wave character of acoustical fields.  The presented higher methods include the concepts of “Mirror Point Sources” and “Corner sources which allow for an excellent approximation of complex room geometries and even equipped rooms. In contrast to classical description, this book extends the theory of sound fields describing them by their complex sound pressure and the particle velocity. This approach enables accurate descriptions of interference and absorption phenomena.

  17. RILIS laser room

    CERN Multimedia

    2016-01-01

    Footage of the RILIS laser room at ISOLDE. The Resonance Ionization Laser Ion Source (RILIS) is a chemically selective ion source which relies on resonant excitation of atomic transitions using tunable laser radiation. This video shows you the laser table with the different lenses and optics as well as an overview of the RILIS laser setup. It also shows laser light with different colors and operation by the RILIS laser experts. The last part of the video shows you the laser path from the RILIS laser room into the ISOLDE GPS separator room where it enters the GPS separator magnet.

  18. RILIS laser room HD

    CERN Multimedia

    2016-01-01

    Footage of the RILIS laser room at ISOLDE. The Resonance Ionization Laser Ion Source (RILIS) is a chemically selective ion source which relies on resonant excitation of atomic transitions using tunable laser radiation. This video shows you the laser table with the different lenses and optics as well as an overview of the RILIS laser setup. It also shows laser light with different colors and operation by the RILIS laser experts. The last part of the video shows you the laser path from the RILIS laser room into the ISOLDE GPS separator room where it enters the GPS separator magnet.

  19. 加强医院整形美容门诊手术室管理控制医院感染%Improving management of cosmetic surgery outpatient operating room to control nosocomial infection

    Institute of Scientific and Technical Information of China (English)

    王艳; 董薪; 张金凤; 孙建荷

    2011-01-01

    目的 探讨医院整形美容门诊手术室安全有效的管理措施,加强整形美容手术各个环节管理,预防和控制医院感染. 方法 通过加强组织领导,规范手术室环境、手术物品、手术人员等各个环节管理, 建立健全整形美容手术室医院感染控制体系. 结果 加强了整形美容手术室医院感染的管理体系,有效地预防和控制了医院感染,提高了手术室医疗护理质量. 结论 采取严格规范系统的整形美容手术管理措施,可以有效控制医院感染的发生,对加强医院规范化管理,控制医院感染具有积极重要的意义.%OBJECTIVE To discuss the effective measures for the safety of cosmetic surgery in outpatient operating room and strengthen the management of every links of cosmetic surgery to prevent and control the incidence of nosocomial infection. METHODS By means of reinforcing the administrative performance, the links to the operating room management, such as the environment of operating room, supervision of operation materials and surgical staff, were regulated to establish and perfect the control system of hospital infection in cosmetic surgery operating room. RESULTS The administrative system of nosocomial infection, the effective prevention and control of nosocomial infection in cosmetic surgery operation room and the quality of medical care in cosmetic surgery operation room had been improved. CONCLUSION Adopting the strict, standard and systemic management in cosmetic surgery can effectively control the occurrence of hospital infection and improve the quality of medical nursing and ensure the medical security, which has the positive significance to the standardized management and control of nosocomial infection.

  20. A Review of Modern Control Strategies for Clinical Evaluation of Propofol Anesthesia Administration Employing Hypnosis Level Regulation

    Science.gov (United States)

    Ilyas, Muhammad; Bilal, Muhammad; Mahmood, Khalid; Ali Riaz, Raja

    2017-01-01

    Regulating the depth of hypnosis during surgery is one of the major objectives of an anesthesia infusion system. Continuous administration of Propofol infusion during surgical procedures is essential but it unduly increases the load of an anesthetist working in a multitasking scenario in the operation theatre. Manual and target controlled infusion systems are not appropriate to handle instabilities like blood pressure and heart rate changes arising due to interpatient and intrapatient variability. Patient safety, large interindividual variability, and less postoperative effects are the main factors motivating automation in anesthesia administration. The idea of automated system for Propofol infusion excites control engineers to come up with more sophisticated systems that can handle optimum delivery of anesthetic drugs during surgery and avoid postoperative effects. A linear control technique is applied initially using three compartmental pharmacokinetic and pharmacodynamic models. Later on, sliding mode control and model predicative control achieve considerable results with nonlinear sigmoid model. Chattering and uncertainties are further improved by employing adaptive fuzzy control and H∞ control. The proposed sliding mode control scheme can easily handle the nonlinearities and achieve an optimum hypnosis level as compared to linear control schemes, hence preventing mishaps such as underdosing and overdosing of anesthesia. PMID:28466018

  1. A Review of Modern Control Strategies for Clinical Evaluation of Propofol Anesthesia Administration Employing Hypnosis Level Regulation

    Directory of Open Access Journals (Sweden)

    Muhammad Ilyas

    2017-01-01

    Full Text Available Regulating the depth of hypnosis during surgery is one of the major objectives of an anesthesia infusion system. Continuous administration of Propofol infusion during surgical procedures is essential but it unduly increases the load of an anesthetist working in a multitasking scenario in the operation theatre. Manual and target controlled infusion systems are not appropriate to handle instabilities like blood pressure and heart rate changes arising due to interpatient and intrapatient variability. Patient safety, large interindividual variability, and less postoperative effects are the main factors motivating automation in anesthesia administration. The idea of automated system for Propofol infusion excites control engineers to come up with more sophisticated systems that can handle optimum delivery of anesthetic drugs during surgery and avoid postoperative effects. A linear control technique is applied initially using three compartmental pharmacokinetic and pharmacodynamic models. Later on, sliding mode control and model predicative control achieve considerable results with nonlinear sigmoid model. Chattering and uncertainties are further improved by employing adaptive fuzzy control and H∞ control. The proposed sliding mode control scheme can easily handle the nonlinearities and achieve an optimum hypnosis level as compared to linear control schemes, hence preventing mishaps such as underdosing and overdosing of anesthesia.

  2. A randomized controlled study comparing room air with carbon dioxide for abdominal pain, distention, and recovery time in patients undergoing colonoscopy.

    Science.gov (United States)

    Chen, Yen-Ju; Lee, Jennifer; Puryear, Magaly; Wong, Roy K H; Lake, Jason M; Maydonovitch, Corrine L; Belle, Lavern; Moawad, Fouad J

    2014-01-01

    Colonoscopy remains the gold standard for colorectal cancer screening. Many barriers to the procedure exist including the possibility of abdominal discomfort that may occur with insufflation. Carbon dioxide (CO2), which is rapidly absorbed in the blood stream, is an alternate method used to distend the lumen during colonoscopy. The goal of this study was to compare patient discomfort, abdominal girth, and recovery time in 2 groups of patients randomized to CO2 versus room air insufflation during colonoscopy. Using a Wong-Baker score, we found statistical difference in postprocedural discomfort levels (CO2 Group: 1.15 ± 2.0 vs. room air: 0.41 ± 0.31, p = .015) and a significantly greater increase in abdominal girth over CO2 immediately postprocedure (room air: 1.06 ± 1.29 inches vs. CO2: 0.56 ± 0.73 inches, p = .054) girth immediately postprocedure; however, recovery time was similar between the 2 study arms (CO2: 9.1 ± 16.2 minutes vs. room air: 10.2 ± 18.6 minutes, p = .713). Further studies are needed to determine whether CO2 is cost-effective and improves patient satisfaction with colonoscopy.

  3. Methodology for the LABIHS PWR simulator modernization

    Energy Technology Data Exchange (ETDEWEB)

    Jaime, Guilherme D.G.; Oliveira, Mauro V., E-mail: gdjaime@ien.gov.b, E-mail: mvitor@ien.gov.b [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2011-07-01

    The Human-System Interface Laboratory (LABIHS) simulator is composed by a set of advanced hardware and software components whose goal is to simulate the main characteristics of a Pressured Water Reactor (PWR). This simulator serves for a set of purposes, such as: control room modernization projects; designing of operator aiding systems; providing technological expertise for graphical user interfaces (GUIs) designing; control rooms and interfaces evaluations considering both ergonomics and human factors aspects; interaction analysis between operators and the various systems operated by them; and human reliability analysis in scenarios considering simulated accidents and normal operation. The simulator runs in a PA-RISC architecture server (HPC3700), developed nearby 2000's, using the HP-UX operating system. All mathematical modeling components were written using the HP Fortran-77 programming language with a shared memory to exchange data from/to all simulator modules. Although this hardware/software framework has been discontinued in 2008, with costumer support ceasing in 2013, it is still used to run and operate the simulator. Due to the fact that the simulator is based on an obsolete and proprietary appliance, the laboratory is subject to efficiency and availability issues, such as: downtime caused by hardware failures; inability to run experiments on modern and well known architectures; and lack of choice of running multiple simulation instances simultaneously. This way, there is a need for a proposal and implementation of solutions so that: the simulator can be ported to the Linux operating system, running on the x86 instruction set architecture (i.e. personal computers); we can simultaneously run multiple instances of the simulator; and the operator terminals run remotely. This paper deals with the design stage of the simulator modernization, in which it is performed a thorough inspection of the hardware and software currently in operation. Our goal is to

  4. Predicting Acoustics in Class Rooms

    DEFF Research Database (Denmark)

    Christensen, Claus Lynge; Rindel, Jens Holger

    2005-01-01

    Typical class rooms have fairly simple geometries, even so room acoustics in this type of room is difficult to predict using today's room acoustic computer modeling software. The reasons why acoustics of class rooms are harder to predict than acoustics of complicated concert halls might...

  5. Modern Biotechnology in China

    Science.gov (United States)

    Wang, Qing-Zhao; Zhao, Xue-Ming

    In recent years, with the booming economy, the Chinese government has increased its financial input to biotechnology research, which has led to remarkable achievements by China in modern biotechnology. As one of the key parts of modern biotechnology, industrial biotechnology will be crucial for China's sustainable development in this century. This review presents an overview of Chinese industrial biotechnology in last 10 years. Modern biotechnology had been classified into metabolic engineering and systems biology framework. Metabolic engineering is a field of broad fundamental and practical concept so we integrated the related technology achievements into the real practices of many metabolic engineering cases, such as biobased products production, environmental control and others. Now metabolic engineering is developing towards the systems level. Chinese researchers have also embraced this concept and have contributed invaluable things in genomics, transcriptomics, proteomics and related bioinformatics. A series of advanced laboratories or centers were established which will represent Chinese modern biotechnology development in the near future. At the end of this review, metabolic network research advances have also been mentioned.

  6. Modern biotechnology in China.

    Science.gov (United States)

    Wang, Qing-Zhao; Zhao, Xue-Ming

    2010-01-01

    In recent years, with the booming economy, the Chinese government has increased its financial input to biotechnology research, which has led to remarkable achievements by China in modern biotechnology. As one of the key parts of modern biotechnology, industrial biotechnology will be crucial for China's sustainable development in this century. This review presents an overview of Chinese industrial biotechnology in last 10 years. Modern biotechnology had been classified into metabolic engineering and systems biology framework. Metabolic engineering is a field of broad fundamental and practical concept so we integrated the related technology achievements into the real practices of many metabolic engineering cases, such as biobased products production, environmental control and others. Now metabolic engineering is developing towards the systems level. Chinese researchers have also embraced this concept and have contributed invaluable things in genomics, transcriptomics, proteomics and related bioinformatics. A series of advanced laboratories or centers were established which will represent Chinese modern biotechnology development in the near future. At the end of this review, metabolic network research advances have also been mentioned.

  7. Counselor-Versus Provider-Based HIV Screening in the Emergency Department: Results From the Universal Screening for HIV Infection in the Emergency Room (USHER) Randomized Controlled Trial

    Science.gov (United States)

    Walensky, Rochelle P.; Reichmann, William M.; Arbelaez, Christian; Wright, Elizabeth; Katz, Jeffrey N.; Seage, George R.; Safren, Steven A.; Hare, Anna Q.; Novais, Anna; Losina, Elena

    2012-01-01

    Objective We compare rates of rapid HIV testing, test offer, and acceptance in an urban emergency department (ED) when conducted by dedicated HIV counselors versus current members of the ED staff. Methods The Universal Screening for HIV Infection in the Emergency Room [USHER] trial is a prospective randomized controlled trial that implemented an HIV screening program in the ED of an urban tertiary medical center. ED patients were screened and consented for trial enrollment by an USHER research assistant. Eligible subjects were randomized to rapid HIV testing (oral OraQuick) offered by a dedicated counselor (counselor arm) or by an ED provider (provider arm). In the counselor arm, counselors—without other clinical responsibilities—assumed nearly all testing-related activities (consent, counseling, delivery of test results). In the provider arm, trained ED emergency service assistants (nursing assistants) consented and tested the participant in the context of other ED-related responsibilities. In this arm, ED house officers, physician assistants, or attending physicians provided HIV test results to trial participants. Outcome measures were rates of HIV testing and test offer among individuals consenting for study participation. Among individuals offered the test, test acceptance was also measured. Results From February 2007 through July 2008, 8,187 eligible patients were approached in the ED, and 4,855 (59%) consented and were randomized to trial participation. The mean age was 37 years, 65% were women, and 42% were white. The overall testing rate favored the counselor arm (57% versus 27%; P < .001); 80% (1,959/2,446) of subjects in the counselor arm were offered an HIV test compared with 36% (861/2,409) in the provider arm (P < .001). HIV test acceptance was slightly higher in the provider arm (counselor arm 71% versus provider arm 75%; P = .025). Conclusion Routine rapid HIV testing in the ED was accomplished more frequently by dedicated HIV counselors than by

  8. Development of digital device based work verification system for cooperation between main control room operators and field workers in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Min, E-mail: jewellee@kaeri.re.kr [Korea Atomic Energy Research Institute, 305-353, 989-111 Daedeok-daero, Yuseong-gu, Daejeon (Korea, Republic of); Department of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology, 373-1, Guseong-dong, Yuseong-gu, Daejeon 305-701 (Korea, Republic of); Lee, Hyun Chul, E-mail: leehc@kaeri.re.kr [Korea Atomic Energy Research Institute, 305-353, 989-111 Daedeok-daero, Yuseong-gu, Daejeon (Korea, Republic of); Ha, Jun Su, E-mail: junsu.ha@kustar.ac.ae [Department of Nuclear Engineering, Khalifa University of Science Technology and Research, Abu Dhabi P.O. Box 127788 (United Arab Emirates); Seong, Poong Hyun, E-mail: phseong@kaist.ac.kr [Department of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology, 373-1, Guseong-dong, Yuseong-gu, Daejeon 305-701 (Korea, Republic of)

    2016-10-15

    Highlights: • A digital device-based work verification and cooperation support system was developed. • Requirements were derived by interviewing field operators having experiences with mobile-based work support systems. • The usability of the proposed system was validated by conducting questionnaire surveys. • The proposed system will be useful if the manual or the set of guidelines is well constructed. - Abstract: Digital technologies have been applied in the nuclear field to check task results, monitor events and accidents, and transmit/receive data. The results of using digital devices have proven that these devices can provide high accuracy and convenience for workers, allowing them to obtain obvious positive effects by reducing their workloads. In this study, as one step forward, a digital device-based cooperation support system, the nuclear cooperation support and mobile documentation system (Nu-COSMOS), is proposed to support communication between main control room (MCR) operators and field workers by verifying field workers’ work results in nuclear power plants (NPPs). The proposed system consists of a mobile based information storage system to support field workers by providing various functions to make workers more trusted by MCR operators; also to improve the efficiency of meeting, and a large screen based information sharing system supports meetings by allowing both sides to share one medium. The usability of this system was estimated by interviewing field operators working in nuclear power plants and experts who have experience working as operators. A survey to estimate the usability of the suggested system and the suitability of the functions of the system for field working was conducted for 35 subjects who have experience in field works or with support system development-related research. The usability test was conducted using the system usability scale (SUS), which is widely used in industrial usability evaluation. Using questionnaires

  9. Carpenter in White Room

    Science.gov (United States)

    1962-01-01

    Inside Hangar S at the White Room Facility at Cape Canaveral, Florida, Mercury astronaut M. Scott Carpenter examines the honeycomb protective material on the main pressure bulkhead (heat shield) of his Mercury capsule nicknamed 'Aurora 7.'

  10. Use of modern tomato breeding germplasm for deciphering the genetic control of agronomical traits by Genome Wide Association study.

    Science.gov (United States)

    Bauchet, Guillaume; Grenier, Stéphane; Samson, Nicolas; Bonnet, Julien; Grivet, Laurent; Causse, Mathilde

    2017-05-01

    A panel of 300 tomato accessions including breeding materials was built and characterized with >11,000 SNP. A population structure in six subgroups was identified. Strong heterogeneity in linkage disequilibrium and recombination landscape among groups and chromosomes was shown. GWAS identified several associations for fruit weight, earliness and plant growth. Genome-wide association studies (GWAS) have become a method of choice in quantitative trait dissection. First limited to highly polymorphic and outcrossing species, it is now applied in horticultural crops, notably in tomato. Until now GWAS in tomato has been performed on panels of heirloom and wild accessions. Using modern breeding materials would be of direct interest for breeding purpose. To implement GWAS on a large panel of 300 tomato accessions including 168 breeding lines, this study assessed the genetic diversity and linkage disequilibrium decay and revealed the population structure and performed GWA experiment. Genetic diversity and population structure analyses were based on molecular markers (>11,000 SNP) covering the whole genome. Six genetic subgroups were revealed and associated to traits of agronomical interest, such as fruit weight and disease resistance. Estimates of linkage disequilibrium highlighted the heterogeneity of its decay among genetic subgroups. Haplotype definition allowed a fine characterization of the groups and their recombination landscape revealing the patterns of admixture along the genome. Selection footprints showed results in congruence with introgressions. Taken together, all these elements refined our knowledge of the genetic material included in this panel and allowed the identification of several associations for fruit weight, plant growth and earliness, deciphering the genetic architecture of these complex traits and identifying several new loci useful for tomato breeding.

  11. Possibilities and limitations of control of harmful organisms in modern sweet cherry plantations according to integrated principles

    OpenAIRE

    Šubić, Milorad

    2016-01-01

    Sweet cherry (Prunus avium) as fruit species is not very demanding when it comes to control of harmful organisms. In order to control disease agents and pests of sweet cherries, it is important to reduce the possible damages by selecting appropriate varieties before planting. In general, varieties with thicker skin and with firm flesh of the fruit are less susceptible to rot caused by the fungus Monilinia, while the varieties that ripen earlier suffer fewer attacks by cherry fruit fly (Rhagol...

  12. Modern power converter drives. Drive systems, power electronics, machines, mechatronics and motion control. 5. rev. and enl. ed.; Moderne Stromrichterantriebe. Antriebssystem, Leistungselektronik, Maschinen, Mechatronik und Motion Control, Arbeitsweise drehzahlveraenderbarer Antriebe mit Stromrichtern und Antriebsvernetzung

    Energy Technology Data Exchange (ETDEWEB)

    Brosch, P.F.

    2008-07-01

    This book informs students and practicians on variable-speed drives. Constructional engineers, technicians and others are given a practical tool for their daily work. - Fundamentals of motive power engineering - power converter components - electric machines - power converter drives with commutator motors - power converter drives with induction machines - integrated drive systems - motion control and mechatronics - selection and dimensioning of variable-speed drives converter measuring engineering - electromagnetic compatibility, with examples - measurements on power converter drives with variable speed adjustment - electromagnetic compatibility. (orig./GL)

  13. Anthropology and Multiple Modernities

    DEFF Research Database (Denmark)

    Thomassen, Bjørn

    , as the concept was pluralized into a variety of forms: multiple modernities, parallel modernities, manifold modernities, alternative modernities, competing modernities, reflexive modernities, early modernities, other modernities – the list still unfolding. By reviewing various attempts to conceptualise...... configurations. However, if the current pluralizing of modernity ultimately serves to describe the variety of cultural forms that co-exist in the World today, the analytical value of the concept risks being watered down, and little is gained in perspective. Arguably, other concepts would have served the purpose...

  14. Appetite control and energy balance regulation in the modern world: reward-driven brain overrides repletion signals.

    Science.gov (United States)

    Zheng, H; Lenard, N R; Shin, A C; Berthoud, H-R

    2009-06-01

    Powerful biological mechanisms evolved to defend adequate nutrient supply and optimal levels of body weight/adiposity. Low levels of leptin indicating food deprivation and depleted fat stores have been identified as the strongest signals to induce adaptive biological actions such as increased energy intake and reduced energy expenditure. In concert with other signals from the gut and metabolically active tissues, low leptin levels trigger powerful activation of multiple peripheral and brain systems to restore energy balance. It is not just neurons in the arcuate nucleus, but many other brain systems involved in finding potential food sources, smelling and tasting food, and learning to maximize rewarding effects of foods, that are affected by low leptin. Food restriction and fat depletion thus lead to a 'hungry' brain, preoccupied with food. By contrast, because of less (adaptive thrifty fuel efficiency) or lost (lack of predators) evolutionary pressure, the upper limits of body weight/adiposity are not as strongly defended by high levels of leptin and other signals. The modern environment is characterized by the increased availability of large amounts of energy-dense foods and increased presence of powerful food cues, together with minimal physical procurement costs and a sedentary lifestyle. Much of these environmental influences affect cortico-limbic brain areas concerned with learning and memory, reward, mood and emotion. Common obesity results when individual predisposition to deal with a restrictive environment, as engraved by genetics, epigenetics and/or early life experience, is confronted with an environment of plenty. Therefore, increased adiposity in prone individuals should be seen as a normal physiological response to a changed environment, not in the pathology of the regulatory system. The first line of defense should ideally lie in modifications to the environment and lifestyle. However, as such modifications will be slow and incomplete, it is equally

  15. 浅探现代餐饮业成本核算精细化控制%On Meticulous Control of Cost Accounting of Modern Catering Industry

    Institute of Scientific and Technical Information of China (English)

    宋强

    2013-01-01

      文章分析了现代餐饮业的特点及成本核算弱化的种种表现,剖析了我国现代餐饮业成本管理弱化的原因,并结合笔者多年的财务工作实践,探讨了应如何强化成本核算精细化控制,以提高企业管理水平,适应国民经济发展。%  This paper analyzes the characteristics of modern catering industry and the various manifestations of weakening cost accounting, explores the reasons and discusses how to strengthen cost accounting meticulous control by combining with the author's many years of financial work experience, to improve enterprise management level and adapt to national economic development.

  16. Discussion on Noise and Control Technology of the Main Control Room in Nuclear Power Plant%浅谈核电站主控室噪声及其控制技术

    Institute of Scientific and Technical Information of China (English)

    富喜; 刘海成; 龚凤海

    2013-01-01

    针对国内核电站的主控制室,通过噪声测试与声源识别,研究分析影响其环境噪声的室内外噪声源及其特性,在此基础上提出降低主控室环境噪声的噪声控制技术,并提出对噪声控制设计的多个限制性因素。本研究成果为低噪声主控室设计提供理论指导和工程经验。%Sound source influencing on interior noise of the main control room in nuclear power plant is researched by noise testing and sound source identification , and sound characteristic are analysised. Control technology about reduce the MCR interior noise is investigated. The limiting factors for noise reduction design are presented. Research result will instruct the acoustic design of the low noise MCR, and been referenced by engineering.

  17. The vascular hybrid room--operating room of the future.

    Science.gov (United States)

    Hudorović, Narcis; Rogan, Suncica Andreja; Lovricević, Ivo; Zovak, Mario; Schmidt, Sasa

    2010-09-01

    The last two decades have seen a paradigm shift in the treatment of vascular related diseases from once traditional open surgical repairs to the entire vascular tree being amenable to percutaneous interventions. Neither the classic operating room nor the conventional angiography suite is optimal for both open surgery and endovascular procedures. Important issues for the vascular hybrid operating room include quality of the imaging equipment, radiation burden, ease of use of the equipment, need for specially trained personnel, ergonomics, ability to perform both open and percutaneous procedures, sterile environments, as well as quality and efficiency of patient care. The most important feature of working in a dedicated hybrid vascular suite should be the ability to attain best treatment of vascular patients. Whether the interventional radiologist or the vascular surgeon uses the facilities is of less importance. Establishment of an endovascular operating room suite has the benefit of a sterile environment, and the possibility of performing hybrid procedures and conversions when necessary. Moreover, angiography immediately before treatment gives contemporary anatomical information, and after treatment provides quality control. Consequently, better quality and service can be provided to the individual patient. These changes in the treatment of vascular disease require that a new type of vascular specialist, named 'vascular hybrid surgeon', trained to perform both endovascular and open surgical procedures in this highly complex patient group.

  18. Human reliability and the control of continuous processes: case study of TRANSPETRO gas control center room; A confiabilidade humana no controle de processos continuos: estudo de caso no centro de controle de gasodutos da TRANSPETRO

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Venetia; Zamberlan, Maria Cristina; Setti, Egle [Instituto Nacional de Tecnologia (INT), Rio de Janeiro, RJ (Brazil); Faertes, Denise; Figueiras, Luciana Heil; Marques, Arnaldo; Franca, Andre Guedes da [PETROBRAS Transporte S.A. (TRANSPETRO), Rio de Janeiro, RJ (Brazil); Diniz, Vaner; Melo, Paulo Fernando Ferreira Frutuoso e [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia. Programa de Engenharia Nuclear

    2005-07-01

    This review presents a study using data from the activities of control of operations into the Center of Control Operational of Gas pipelines from TRANSPETRO. These study used the methodology of Analysis Ergonomic of Work (AET). Twenty hours of systematic observation have been performed from the activities of the operators and the supervisors into the CCG in different shifts with different staffs. The data obtained reveals the dynamics from the activities of control facing the increase of automation as well the strategies and adjustments that are performed by the operators with the increase of complexity of the systems they shall control. With the treatment of data we verify that occurs an important increasing of the activities, that interferes on to another, and that generates the loss of cooperation between operators, errors on the exchanges of information and so on. The survey from real activity at work was fundamental for the apprehension of the existing risks and for the generation of proposals to the improvement of the control of the process in the CCG. (author)

  19. On the role of taxation and tax control institutions in implementation of sustainable development strategy in modern Russia

    Directory of Open Access Journals (Sweden)

    Zamir Sagirovich Yakupov

    2015-03-01

    Full Text Available Objective to research scientific approaches to the institution of tax control taking into account the basic theories and scientific concepts that affect the functioning of this institution. Methods logical and statistical methods were applied as well as methods of deduction and induction scientific abstraction. Results it is proved that sustainable economic development can be achieved by enhancing the financial and taxation mechanism. The institute of tax control is viewed as a softener of economic crises. Mechanisms are proposed to influence the crises and to minimize the losses of both taxpayers and the state. Scientific novelty the model is proposed of the taxation tools and mechanisms for sustainable development of Russia. Practical value the possibility to increase the value and efficiency of the taxation mechanisms for sustainable development. nbsp

  20. Analysis of the Effect of Disinfection Management in Operating Room on Hospital Infection Control%手术室消毒对感染控制的效果分析

    Institute of Scientific and Technical Information of China (English)

    程锐; 陈伟丽; 叶旭霞

    2016-01-01

    Objective To explore the effect of disinfection management in operating room on hospital infection control.Methods Disinfection and sterilization monitoring data from January 2013 to December 2014 when traditional operating room management was implemented in our hospital was randomly selected as the control group. Disinfection and sterilization monitoring data from January 2015 to December 2015 when disinfection management in operating room was implemented in our hospital was randomly selected as the treatment group. Comparison of the disinfection effect in operating room and incision infection rate between two groups was made.Results The qualified rate of the air, disinfection articles and hand disinfection of medical staffs in operating room after disinfection management was significantly higher than that in control group with statistically significant difference (P<0.05). The infection rate of surgical patients after the implementation of disinfection management in operating room was lower than that in the control group with statistically significant difference (P<0.05).Conclusion Strengthening the disinfection management in operation room can promote the formation of a good habit for medical personnel in operation room and reduce the incision infection rate.%目的探讨手术室消毒管理对医院感染控制的效果。方法随机抽取2013年1月至2014年12月我院实施传统手术室管理模式期间的消毒灭菌监测资料作为对照组,随机抽取2015年1月至2015年12月我院实施手术室消毒管理模式期间的消毒灭菌监测资料作为观察组,对比两组手术室消毒效果及研究期间手术室收治患者切口感染率。结果实施手术室消毒管理后手术室空气、消毒物品及医护人员手消毒合格率均较传统手术室管理提高,差异有统计学意义(P<0.05);实施手术室消毒管理后各科室手术患者手术部位感染率均较传统手术室管理降低,